WorldWideScience

Sample records for arterial blood sampling

  1. 21 CFR 868.1100 - Arterial blood sampling kit.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...

  2. Long-term facial artery catheter implantation for serial arterial blood sampling and invasive arterial blood pressure measurement in horses.

    Science.gov (United States)

    Dias, Deborah Penteado Martins; Teixeira, Luisa Gouvêa; Canola, Paulo Aléscio; Albernaz, Raquel Mincarelli; Marques, José Antônio; Neto, José Corrêa de Lacerda

    2012-06-01

    The purpose of this investigation was to evaluate surgical catheter implantation in the facial artery of horses and the long-term maintenance of such arteries using heparin and ascorbic acid as filling solution. Nine horses were implanted with a polyurethane catheter. The catheters were flushed with a heparin/ascorbic acid solution every 8h and remained patent for 25 days. Arterial blood samples were collected twice a day, and one exercise test that included serial blood samples and arterial pressure recordings was performed on a treadmill. Polyurethane catheters surgically implanted in the facial artery can be kept patent by filling with a heparin/ascorbic acid solution and provide convenient invasive arterial access in horses which is suitable for use for serial blood sampling and blood pressure recordings, even during exercise on treadmill. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  4. A femoral arteriovenous shunt facilitates arterial whole blood sampling in animals

    International Nuclear Information System (INIS)

    Weber, Bruno; Burger, Cyrill; Buck, Alfred; Biro, Peter

    2002-01-01

    In this study we evaluated on-line continuous blood sampling in a femoral arteriovenous (a-v) shunt for use in quantitative tracer studies using gamma-emitting radionuclides in animals. The shunt consisted of 40 cm polyethylene tubing (PE-50) guided through a coincidence probe. Two three-way valves allowed blood pressure measurements and tracer injection. Blood flow in the shunt and the impulse response function (IRF) were assessed using heparinized human blood mixed with fluorine-18 fluorodeoxyglucose (FDG). In vivo experiments were performed in eight male rats (300-350 g) anaesthetized with halothane. In three rats, manual blood sampling was performed in parallel with on-line sampling. In another five animals, the arterial whole blood activity was recorded on-line for 40 min. For the experiments 150-180 MBq FDG was injected over 35 s. Blood flow in the shunt was 23.6, 29.2 and 42.8 ml/h at 100, 120 and 160 mmHg, respectively. The IRF was characterized by minimal dispersion (1-2 s FWHM). Deconvolution of the measured arterial input curves with the IRF changed the measured curve only minimally. Whole blood radioactivity concentration derived from manual and on-line sampling were in excellent agreement. The curves derived from on-line sampling were of high statistical quality. In conclusion, a femoral a-v shunt allows multiple manipulations such as measurement of the arterial whole blood activity, continuous blood pressure monitoring, injection of the tracer and collection of blood samples if necessary. It is not associated with blood loss if the collection of blood samples is not required. It is more convenient to use than manual sampling, the peak of the input curve is never missed and the input curves are of high statistical quality. (orig.)

  5. Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses.

    Science.gov (United States)

    Jousi, Milla; Saikko, Simo; Nurmi, Jouni

    2017-09-11

    Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT® POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO

  6. Measurement of regional cerebral blood flow using one-point venous blood sampling and causality model. Evaluation by comparing with conventional continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Sone, Teruki; Takahashi, Yoshitake

    2008-01-01

    Optimal setting of the input function is essential for the measurement of regional cerebral blood flow (rCBF) based on the microsphere model using N-isopropyl-4-[ 123 I]iodoamphetamine ( 123 I-IMP), and usually the arterial 123 I-IMP concentration (integral value) in the initial 5 min is used for this purpose. We have developed a new convenient method in which 123 I-IMP concentration in arterial blood sample is estimated from that in venous blood sample. Brain perfusion single photon emission computed tomography (SPECT) with 123 I-IMP was performed in 110 cases of central nervous system disorders. The causality was analyzed between the various parameters of SPECT data and the ratio of octanol-extracted arterial radioactivity concentration during the first 5 min (Caoct) to octanol-extracted venous radioactivity concentration at 27 min after intravenous injection of 123 I-IMP (Cvoct). A high correlation was observed between the measured and estimated values of Caoct/Cvoct (r=0.856) when the following five parameters were included in the regression formula: radioactivity concentration in venous blood sampled at 27 min (Cv), Cvoct, Cvoct/Cv, and total brain radioactivity counts that were measured by a four-head gamma camera 5 min and 28 min after 123 I-IMP injection. Furthermore, the rCBF values obtained using the input parameters estimated by this method were also highly correlated with the rCBF values measured using the continuous arterial blood sampling method (r=0.912). These results suggest that this method would serve as the new, convenient and less invasive method of rCBF measurement in clinical setting. (author)

  7. Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples.

    Science.gov (United States)

    Mohammadhoseini, Elham; Safavi, Enayat; Seifi, Sepideh; Seifirad, Soroush; Firoozbakhsh, Shahram; Peiman, Soheil

    2015-03-01

    Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.

  8. Measurement of regional cerebral blood flow using one-point arterial blood sampling and microsphere model with 123I-IMP. Correction of one-point arterial sampling count by whole brain count ratio

    International Nuclear Information System (INIS)

    Makino, Kenichi; Masuda, Yasuhiko; Gotoh, Satoshi

    1998-01-01

    The experimental subjects were 189 patients with cerebrovascular disorders. 123 I-IMP, 222 MBq, was administered by intravenous infusion. Continuous arterial blood sampling was carried out for 5 minutes, and arterial blood was also sampled once at 5 minutes after 123 I-IMP administration. Then the whole blood count of the one-point arterial sampling was compared with the octanol-extracted count of the continuous arterial sampling. A positive correlation was found between the two values. The ratio of the continuous sampling octanol-extracted count (OC) to the one-point sampling whole blood count (TC5) was compared with the whole brain count ratio (5:29 ratio, Cn) using 1-minute planar SPECT images, centering on 5 and 29 minutes after 123 I-IMP administration. Correlation was found between the two values. The following relationship was shown from the correlation equation. OC/TC5=0.390969 x Cn-0.08924. Based on this correlation equation, we calculated the theoretical continuous arterial sampling octanol-extracted count (COC). COC=TC5 x (0.390969 x Cn-0.08924). There was good correlation between the value calculated with this equation and the actually measured value. The coefficient improved to r=0.94 from the r=0.87 obtained before using the 5:29 ratio for correction. For 23 of these 189 cases, another one-point arterial sampling was carried out at 6, 7, 8, 9 and 10 minutes after the administration of 123 I-IMP. The correlation coefficient was also improved for these other point samplings when this correction method using the 5:29 ratio was applied. It was concluded that it is possible to obtain highly accurate input functions, i.e., calculated continuous arterial sampling octanol-extracted counts, using one-point arterial sampling whole blood counts by performing correction using the 5:29 ratio. (K.H.)

  9. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    Science.gov (United States)

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  10. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, Flemming; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  11. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  12. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...

  13. Corrections of arterial input function for dynamic H215O PET to assess perfusion of pelvic tumours: arterial blood sampling versus image extraction

    International Nuclear Information System (INIS)

    Luedemann, L; Sreenivasa, G; Michel, R; Rosner, C; Plotkin, M; Felix, R; Wust, P; Amthauer, H

    2006-01-01

    Assessment of perfusion with 15 O-labelled water (H 2 15 O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF

  14. A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (part 2). A study of time correction of one-point blood sample count

    International Nuclear Information System (INIS)

    Masuda, Yasuhiko; Makino, Kenichi; Gotoh, Satoshi

    1999-01-01

    In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123 I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123 I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised out method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123 I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123 I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step. (author)

  15. Measurement of cerebral blood flow the blood sampling method using 99mTc-ECD. Simultaneous scintigram scanning of arterial blood samples and the brain with a gamma camera

    International Nuclear Information System (INIS)

    Hachiya, Takenori; Inugami, Atsushi; Iida, Hidehiro; Mizuta, Yoshihiko; Kawakami, Takeshi; Inoue, Minoru

    1999-01-01

    To measure regional cerebral blood flow (rCBF) by blood sampling using 99m Tc-ECD we devised a method of measuring the radioactive concentration in arterial blood sample with a gamma camera. In this method the head and a blood sample are placed within the same visual field to record the SPECT data of both specimens simultaneously. The results of an evaluation of the counting rate performance, applying the 30 hours decaying method using 99m Tc solution showed that this method is not comparable to the well-type scintillation counter and in clinical cases the active concentration in arterial blood sample remained well within the dynamic range. In addition, examination of the influence of scattered radiation from the brain by the dilution method showed that it was negligible at a distance of more than 7.5 cm between the brain and the arterial blood sample. In the present study we placed a head-shaped phantom next to the sample. The results of the examinations suggested that this method is suitable for clinical application, and because it does not require a well-type scintillation counter, it is expected to find wide application. (author)

  16. Quantification of periodontal pathogens in vascular, blood, and subgingival samples from patients with peripheral arterial disease or abdominal aortic aneurysms.

    Science.gov (United States)

    Figuero, Elena; Lindahl, Christeel; Marín, María José; Renvert, Stefan; Herrera, David; Ohlsson, Ola; Wetterling, Thomas; Sanz, Mariano

    2014-09-01

    The aim of this investigation is to quantify periodontal pathogens (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Campylobacter rectus, and Tannerella forsythia) in vascular, blood, and subgingival samples. As a secondary objective, two molecular bacterial identification methods (nested polymerase chain reaction [PCR] and quantitative PCR [qPCR]) are compared. Seventy consecutive patients provided a vascular lesion, a blood sample, and 36 subgingival samples. Bacterial DNA was extracted, and qPCR was used to determine the prevalence and amounts of the target pathogens in each sample. Nested PCR was performed only in the samples from vascular lesions. Periodontal examination was performed in 42 patients. Mann-Whitney U or χ(2) tests were used to compare microbiologic results according to periodontal diagnosis. All targeted periodontal pathogens (A. actinomycetemcomitans, P. gingivalis, T. forsythia, or C. rectus) were detected in subgingival samples, with a prevalence rate of 72.2%, 47.2%, 74.3%, and 82.9%, respectively. In 7.1% and 11.4% of vascular and blood samples, bacterial DNA was detected. One patient was positive for A. actinomycetemcomitans in the three types of samples. No differences were found in the levels of targeted bacteria when comparing patients with and without periodontitis. Prevalence rates obtained with nested PCR were significantly higher than those obtained with qPCR. The presence of A. actinomycetemcomitans was demonstrated in vascular, blood, and subgingival samples in one of 36 patients. These results, although with a very low frequency, may support the hypothesis of a translocation of periodontal pathogens from subgingival microbiota to the bloodstream and then to atheromatous plaques in carotid or other peripheral arteries. Nested PCR is not an adequate method for identifying DNA of periodontal pathogens in low quantities because of the high number of false-negative results.

  17. Quantitative cerebral H215O perfusion PET without arterial blood sampling, a method based on washout rate

    International Nuclear Information System (INIS)

    Treyer, Valerie; Jobin, Mathieu; Burger, Cyrill; Buck, Alfred; Teneggi, Vincenzo

    2003-01-01

    The quantitative determination of regional cerebral blood flow (rCBF) is important in certain clinical and research applications. The disadvantage of most quantitative methods using H 2 15 O positron emission tomography (PET) is the need for arterial blood sampling. In this study a new non-invasive method for rCBF quantification was evaluated. The method is based on the washout rate of H 2 15 O following intravenous injection. All results were obtained with Alpert's method, which yields maps of the washin parameter K 1 (rCBF K1 ) and the washout parameter k 2 (rCBF k2 ). Maps of rCBF K1 were computed with measured arterial input curves. Maps of rCBF k2* were calculated with a standard input curve which was the mean of eight individual input curves. The mean of grey matter rCBF k2* (CBF k2* ) was then compared with the mean of rCBF K1 (CBF K1 ) in ten healthy volunteer smokers who underwent two PET sessions on day 1 and day 3. Each session consisted of three serial H 2 15 O scans. Reproducibility was analysed using the rCBF difference scan 3-scan 2 in each session. The perfusion reserve (PR = rCBF acetazolamide -rCBF baseline ) following acetazolamide challenge was calculated with rCBF k2* (PR k2* ) and rCBF K1 (PR K1 ) in ten patients with cerebrovascular disease. The difference CBF k2* -CBF K1 was 5.90±8.12 ml/min/100 ml (mean±SD, n=55). The SD of the scan 3-scan 1 difference was 6.1% for rCBF k2* and rCBF K1 , demonstrating a high reproducibility. Perfusion reserve values determined with rCBF K1 and rCBF k2* were in high agreement (difference PR k2* -PR K1 =-6.5±10.4%, PR expressed in percentage increase from baseline). In conclusion, a new non-invasive method for the quantitative determination of rCBF is presented. The method is in good agreement with Alpert's original method and the reproducibility is high. It does not require arterial blood sampling, yields quantitative voxel-by-voxel maps of rCBF, and is computationally efficient and easy to implement

  18. Manual versus automated blood sampling

    DEFF Research Database (Denmark)

    Teilmann, A C; Kalliokoski, Otto; Sørensen, Dorte B

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters......, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal...... corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters...

  19. Comparison of arterial and venous blood gases and the effects of analysis delay and air contamination on arterial samples in patients with chronic obstructive pulmonary disease and healthy controls.

    LENUS (Irish Health Repository)

    O'Connor, T M

    2012-01-31

    BACKGROUND: Arterial blood gases (ABGs) are often sampled incorrectly, leading to a \\'mixed\\' or venous sample. Delays in analysis and air contamination are common. OBJECTIVES: We measured the effects of these errors in patients with chronic obstructive pulmonary disease (COPD) exacerbations and controls. METHODS: Arterial and venous samples were analyzed from 30 patients with COPD exacerbation and 30 controls. Venous samples were analysed immediately and arterial samples separated into non-air-contaminated and air-contaminated specimens and analysed at 0, 30, 60, 90 and 180 min. RESULTS: Mean venous pH was 7.371 and arterial pH was 7.407 (p < 0.0001). There was a correlation between venous and arterial pH (r = 0.5347, p < 0.0001). The regression equation to predict arterial pH was: arterial pH = 4.2289 + 0.43113 . venous pH. There were no clinically significant differences in arterial PO associated with analysis delay. A statistically significant decline in pH was detected at 30 min in patients with COPD exacerbation (p = 0.0042) and 90 min in controls (p < 0.0001). A clinically significant decline in pH emerged at 73 min in patients with COPD exacerbation and 87 min in controls. Air contamination was associated with a clinically significant increase in PO in all samples, including those that were immediately analyzed. CONCLUSIONS: Arterial and venous pH differ significantly. Venous pH cannot accurately replace arterial pH. Temporal delays in ABG analysis result in a significant decline in measured pH. ABGs should be analysed within 30 min. Air contamination leads to an immediate increase in measured PO, indicating that air-contaminated ABGs should be discarded.

  20. Comparison of arterial and venous blood gases and the effects of analysis delay and air contamination on arterial samples in patients with chronic obstructive pulmonary disease and healthy controls.

    Science.gov (United States)

    O'Connor, T M; Barry, P J; Jahangir, A; Finn, C; Buckley, B M; El-Gammal, A

    2011-01-01

    Arterial blood gases (ABGs) are often sampled incorrectly, leading to a 'mixed' or venous sample. Delays in analysis and air contamination are common. We measured the effects of these errors in patients with chronic obstructive pulmonary disease (COPD) exacerbations and controls. Arterial and venous samples were analyzed from 30 patients with COPD exacerbation and 30 controls. Venous samples were analysed immediately and arterial samples separated into non-air-contaminated and air-contaminated specimens and analysed at 0, 30, 60, 90 and 180 min. Mean venous pH was 7.371 and arterial pH was 7.407 (p Air contamination was associated with a clinically significant increase in PO₂ in all samples, including those that were immediately analyzed. Arterial and venous pH differ significantly. Venous pH cannot accurately replace arterial pH. Temporal delays in ABG analysis result in a significant decline in measured pH. ABGs should be analysed within 30 min. Air contamination leads to an immediate increase in measured PO₂, indicating that air-contaminated ABGs should be discarded. Copyright © 2010 S. Karger AG, Basel.

  1. Regional cerebral blood flow measurements by a noninvasive microsphere method using 123I-IMP. Comparison with the modified fractional uptake method and the continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Nakano, Seigo; Matsuda, Hiroshi; Tanizaki, Hiroshi; Ogawa, Masafumi; Miyazaki, Yoshiharu; Yonekura, Yoshiharu

    1998-01-01

    A noninvasive microsphere method using N-isopropyl-p-( 123 I)iodoamphetamine ( 123 I-IMP), developed by Yonekura et al., was performed in 10 patients with neurological diseases to quantify regional cerebral blood flow (rCBF). Regional CBF values by this method were compared with rCBF values simultaneously estimated from both the modified fractional uptake (FU) method using cardiac output developed by Miyazaki et al. and the conventional method with continuous arterial blood sampling. In comparison, we designated the factor which converted raw SPECT voxel counts to rCBF values as a CBF factor. A highly significant correlation (r=0.962, p<0.001) was obtained in the CBF factors between the present method and the continuous arterial blood sampling method. The CBF factors by the present method were only 2.7% higher on the average than those by the continuous arterial blood sampling method. There were significant correlation (r=0.811 and r=O.798, p<0.001) in the CBF factor between modified FU method (threshold for estimating total brain SPECT counts; 10% and 30% respectively) and the continuous arterial blood sampling method. However, the CBF factors of the modified FU method showed 31.4% and 62.3% higher on the average (threshold; 10% and 30% respectively) than those by the continuous arterial blood sampling method. In conclusion, this newly developed method for rCBF measurements was considered to be useful for routine clinical studies without any blood sampling. (author)

  2. DETERMINATION OF AMMONIA IN EAR-LOBE CAPILLARY BLOOD IS AN ALTERNATIVE TO ARTERIAL BLOOD AMMONIA

    NARCIS (Netherlands)

    HUIZENGA, [No Value; GIPS, CH; CONN, HO; JANSEN, PLM

    1995-01-01

    Blood ammonia determination is a laboratory test to diagnose hepatic encephalopathy. Arterial blood is superior to peripheral venous blood ammonia because of ammonia metabolism in muscle. We have compared capillary with arterial whole blood ammonia as capillary sampling is an attractive alternative.

  3. Determination of ammonia in ear-lobe capillary blood is an alternative to arterial blood ammonia

    NARCIS (Netherlands)

    Huizenga, J. R.; Gips, C. H.; Conn, H. O.; Jansen, P. L.

    1995-01-01

    Blood ammonia determination is a laboratory test to diagnose hepatic encephalopathy. Arterial blood is superior to peripheral venous blood ammonia because of ammonia metabolism in muscle. We have compared capillary with arterial whole blood ammonia as capillary sampling is an attractive alternative.

  4. Relations between a novel, reliable, and rapid index of arterial compliance (PP-HDI) and well-established inidices of arterial blood pressure (ABP) in a sample of hypertensive elderly subjects.

    Science.gov (United States)

    Bergamini, L; Finelli, M E; Bendini, C; Ferrari, E; Veschi, M; Neviani, F; Manni, B; Pelosi, A; Rioli, G; Neri, M

    2009-01-01

    Hypertension is a risk factor for a long-lasting arterial wall-remodelling leading to stiffness. The rapid method measuring the pulse pressure (PP) by means of the tool of Hypertension Diagnostic Instruments (HDI) called PP-HDI, overcomes some of the problems arising with more-time consuming methods, like ambulatory blood pressure monitoring (ABPM), and give information about the elasticity of the arterial walls. We studied the relationship between the PP-HDI, the large artery compliance (LA-C) and small artery compliance (SA-C) and few well-established indices of arterial blood pressure (ABP) in a sample of 75 hypertensive subjects, aged 65 years and over. Significant correlations between LA-C and heart rate (HR), PP-ABPM and PP-HDI were found. SA-C relates with HR and systolic blood pressure (SBP) measured in lying and standing positions. Applying a stepwise regression analysis, we found that LA-C variance stems from PP-HDI and HR, while SA-C variance stems from SBP in lying position. Receiver operator characteristic (ROC) curves for thresholds of PP showed that PP-HDI reached levels of sensitivity/specificity similar to PP-ABPM. In conclusion, surveillance of ABP through hemo-dynamic indices, in particular of SBP, is essential, nevertheless the advantage of this control is not known in an elderly population where the organ damage is already evident. PP needs necessarily an instrumental measurement. The PP-HDI result is similar in reliability with respect to PPABPM, but is more rapid and well applicable in an elderly population.

  5. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  6. Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Tao; Tsui, Benjamin M. W.; Li, Xin; Vranesic, Melin; Lodge, Martin A.; Gulaldi, Nedim C. M.; Szabo, Zsolt, E-mail: zszabo@jhmi.edu [Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287 (United States)

    2015-11-15

    Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent

  7. Neonatal blood gas sampling methods

    African Journals Online (AJOL)

    You work in a regional neonatal intensive care unit. An 8-day-old ... The baby was born at 28 weeks' gestation with a birth weight of 1. 100 g. ... and arterial blood taken from indwelling arterial lines.2-4 However, even ... tal age of 48 - 72 hours.

  8. A comparative study of simple methods to quantify cerebral blood flow with acetazolamide challenge by using iodine-123-IMP SPECT with one-point arterial sampling

    Energy Technology Data Exchange (ETDEWEB)

    Ohkubo, Masaki [Niigata Univ. (Japan). School of Health Sciences; Odano, Ikuo

    2000-04-01

    The aim of this study was to compare the accuracy of simplified methods for quantifying rCBF with acetazolamide challenge by using {sup 123}I-N-isopropyl-p-iodoamphetamine (IMP) and SPECT with one-point arterial sampling. After acetazolamide administration we quantified rCBF in 12 subjects by the following three methods: (a) the modified microsphere method, (b) the IMP-autoradiographic (ARG) method based on a two-compartment one-parameter model, and (c) the simplified method based on a two-compartment two-parameter model (functional IMP method). The accuracy of these methods was validated by comparing rCBF values with those obtained by the standard method: the super-early microsphere method with continuous withdrawal of arterial blood. On analyzing rCBF in each flow range (0-0.25, 0.25-0.5, 0.5-0.75 and more than 0.75 ml/g/min), rCBF values obtained by both methods (a) and (c) showed significant correlations (p<0.01) with those obtained by the standard method in every range, but rCBF values obtained by method (b) did not significantly correlated in the high flow range (0.5-0.75 and more than 0.75 ml/g/min). Method (c) was found to be the most accurate, even though it needs two serial SPECT scans. When requiring one SPECT scan, method (a) was considered to be superior to method (b) because of its accuracy, especially in high flow regions loaded with acetazolamide. (author)

  9. Continuous intra-arterial blood-gas monitoring

    Science.gov (United States)

    Divers, George A.; Riccitelli, Samuel D.; Blais, Maurice; Hui, Henry K.

    1993-05-01

    Fiber optic technology and optical fluorescence have made the continuous monitoring of arterial blood gases a reality. Practical products that continuously monitor blood gases by use of an invasive sensor are now available. Anesthesiologists and intensive care physicians are beginning to explore the practical implications of this technology. With the advent of intra- arterial blood gas monitors it is possible to assess arterial blood gas values without the labor intensive steps of drawing blood and transporting a blood sample to the lab followed by the actual analysis. These intra-arterial blood gas monitors use new optical sensor technologies that can be reduced in size to the point that the sensor can be inserted into the arterial blood flow through a 20-gauge arterial cannula. In the best of these technologies the sensors accuracy and precision are similar to those in vitro analyzers. This presentation focuses on background technology and in vivo performance of a device developed, manufactured, and marketed by Puritan-Bennett Corporation.

  10. Middle cerebral artery blood velocity during running

    NARCIS (Netherlands)

    Lyngeraa, T. S.; Pedersen, L. M.; Mantoni, T.; Belhage, B.; Rasmussen, L. S.; van Lieshout, J. J.; Pott, F. C.

    2013-01-01

    Running induces characteristic fluctuations in blood pressure (BP) of unknown consequence for organ blood flow. We hypothesized that running-induced BP oscillations are transferred to the cerebral vasculature. In 15 healthy volunteers, transcranial Doppler-determined middle cerebral artery (MCA)

  11. Expression of T helper cell-associated inflammatory mediator mRNAs in cells of bronchoalveolar lavage fluid samples and oxygen concentration in arterial blood samples from healthy horses exposed to hyperbaric oxygen.

    Science.gov (United States)

    Looijen, Maty G P; New, Dallas J; Fischer, Carrie D; Dardari, Rkia; Irwin, Karyn M; Berezowski, Christopher J; Bond, Stephanie L; Léguillette, Renaud

    2016-10-01

    OBJECTIVE To evaluate the mRNA expression of T helper (Th)1, Th2, and Th17 cell-associated inflammatory mediators in cells of bronchoalveolar lavage fluid samples collected from healthy horses exposed to hyperbaric oxygen (HBO) and to monitor blood oxygen concentration during and following HBO therapy. ANIMALS 8 healthy horses. PROCEDURES In a randomized controlled crossover design study, each horse was exposed (beginning day 1) to 100% oxygen at a maximum of 3 atmospheres absolute (304 kPa) daily for 10 days or ambient air at atmospheric pressure in the HBO chamber for an equivalent amount of time (control). Bronchoalveolar lavage fluid samples were collected on days 0 and 10. After validation of candidate reference genes, relative mRNA expressions of various innate inflammatory, Th1 cell-derived, Th2 cell-derived (including eotaxin-2), Th17 cell-derived, and regulatory cytokines were measured by quantitative PCR assays. For 3 horses, arterial blood samples were collected for blood gas analysis during a separate HBO session. RESULTS The optimal combination of reference genes was glyceraldehyde-3-phosphate dehydrogenase, hypoxanthine ribosyltransferase, and ribosomal protein L32. Compared with day 0 findings, expression of eotaxin-2 mRNA was significantly lower (0.12-fold reduction) and the percentage of neutrophils in bronchoalveolar lavage fluid samples was significantly lower on day 10 when horses received HBO therapy. Values of Pao2 rapidly increased (> 800 mm Hg) but immediately decreased to pretreatment values when HBO sessions ended. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that HBO therapy does not increase mRNA expression of inflammatory cytokines, but reduces eotaxin-2 mRNA transcription. The Pao2 increase was transient with no cumulative effects of HBO.

  12. Bedside arterial blood gas monitoring system using fluorescent optical sensors

    Science.gov (United States)

    Bartnik, Daniel J.; Rymut, Russell A.

    1995-05-01

    We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood

  13. Middle cerebral artery blood velocity during running

    DEFF Research Database (Denmark)

    Lyngeraa, Tobias; Pedersen, Lars Møller; Mantoni, T

    2013-01-01

    for eight subjects, respectively, were excluded from analysis because of insufficient signal quality. Running increased mean arterial pressure and mean MCA velocity and induced rhythmic oscillations in BP and in MCA velocity corresponding to the difference between step rate and heart rate (HR) frequencies....... During running, rhythmic oscillations in arterial BP induced by interference between HR and step frequency impact on cerebral blood velocity. For the exercise as a whole, average MCA velocity becomes elevated. These results suggest that running not only induces an increase in regional cerebral blood flow...

  14. Patient identification in blood sampling.

    Science.gov (United States)

    Davidson, Anne; Bolton-Maggs, Paula

    The majority of adverse reports relating to blood transfusions result from human error, including misidentification of patients and incorrect labelling of samples. This article outlines best practice in blood sampling for transfusion (but is recommended for all pathology samples) and the role of patient empowerment in improving safety.

  15. Neonatal blood gas sampling methods | Goenka | South African ...

    African Journals Online (AJOL)

    There is little published guidance that systematically evaluates the different methods of neonatal blood gas sampling, where each method has its individual benefits and risks. This review critically surveys the available evidence to generate a comparison between arterial and capillary blood gas sampling, focusing on their ...

  16. A Comparison of Po2, Pco2, Ph and Bicarbonate in Blood from the Carotid and Coccygeal Arteries of Calves

    OpenAIRE

    Gustin, Pascal; de Groote, A.; Dhem, A. R.; Bakima, M.; Lomba; Lekeux, Pierre

    1988-01-01

    A technique is described for the subcutaneous deviation of the carotid artery into the jugular groove of calves weighing between 90 and 200 kg. This makes sampling arterial blood or chronic cannulation for further experimentation very easy. Values of oxygen tension, carbon dioxide tension, pH and bicarbonate concentration in blood sampled from the ventral coccygeal artery were compared with the values obtained in blood from carotid artery puncture. The high correlations observed indicate that...

  17. Ammonia concentrations in arterial blood, venous blood, and cerebrospinal fluid of dogs with and without congenital extrahepatic portosystemic shunts.

    Science.gov (United States)

    Or, Matan; Devriendt, Nausikaa; Kitshoff, Adriaan M; Peremans, Kathelijne; Vandermeulen, Eva; Paepe, Dominique; Polis, Ingeborgh; Martlé, Valentine; de Rooster, Hilde

    2017-11-01

    OBJECTIVE To compare ammonia concentrations in arterial blood, venous blood, and CSF samples of dogs with and without extrahepatic portosystemic shunts (EHPSS). ANIMALS 19 dogs with congenital EHPSS and 6 healthy control dogs. PROCEDURES All dogs underwent a physical examination and then were anesthetized for transsplenic portal scintigraphy to confirm the presence or absence of EHPSS. While dogs were anesthetized, arterial and venous blood samples and a CSF sample were simultaneously collected for determination of ammonia concentration, which was measured by use of a portable blood ammonia analyzer (device A) and a nonportable biochemical analyzer (device B). Results were compared between dogs with EHPSS and control dogs. RESULTS Arterial, venous, and CSF ammonia concentrations for dogs with EHPSS were significantly greater than those for control dogs. For dogs with EHPSS, ammonia concentrations in both arterial and venous blood samples were markedly increased from the reference range. There was a strong positive correlation between arterial and venous ammonia concentrations and between blood (arterial or venous) and CSF ammonia concentrations. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that blood and CSF ammonia concentrations in dogs with EHPSS were greater than those for healthy dogs and were strongly and positively correlated, albeit in a nonlinear manner. This suggested that the permeability of the blood-brain barrier to ammonia may be abnormally increased in dogs with EHPSS, but further investigation of the relationship between blood or CSF ammonia concentration and clinical signs of hepatic encephalopathy or the surgical outcome for dogs with EHPSS is warranted.

  18. Correlation between arterial blood gas analysis and peripheral blood gas analysis in acid-base unbalance state

    Directory of Open Access Journals (Sweden)

    Hyun Lee Kim

    2012-06-01

    Full Text Available Acid-base unbalance is most common problem in severe ill patient, especially in condition of abnormal renal function state. Acid-base unbalances are respiratory acidosis, respiratory alkalosis, metabolic acidosis, and metabolic alkalosis. Metabolic acidosis is frequently appeared in clinical state. Arterial blood gas analysis is considered as a basic test to the intensive care unit patient and emergency state. Recently some researches were done, comparing with arterial blood gas analysis and venous blood gas analysis. Because of venous blood sampling is safer than arterial blood gas analysis, and beside not so different among them for detecting pH, pCO2, HCO3, except pO2 measuring. This research was done in emergency room, and for explaining no different between arterial blood gas analysis and peripheral blood gas analysis result in acid-base unbalance state patient. Especially in kidney functions decreased state. : The study was done from March, 2010 to January, 2011. The object was 89 peoples who came to emergency room for treating internal medicine problem. (Women 53, average age: 66.7±12.1 Then compare between arterial blood gas analysis and peripheral blood gas analysis. Result: The mean arterial minus venous difference for pH, pCO2, and bicarbonate was −0.0170, 2.6528, and 0.6124. Bland-Altman plot was done for predicting agreement of two groups, and the scale was pH −2.95 to 4.17, pCO2 −4.45 to 9.76, bicarbonate −2.95 to 4.16, in 95% relative. Conclusion: The peripheral blood gas pH, pCO2, bicarbonate level is almost same as arterial blood gas analysis results. And enough to measuring acid-base unbalance state, in absent of arterial blood testing.

  19. Pulsatile spiral blood flow through arterial stenosis.

    Science.gov (United States)

    Linge, Fabian; Hye, Md Abdul; Paul, Manosh C

    2014-11-01

    Pulsatile spiral blood flow in a modelled three-dimensional arterial stenosis, with a 75% cross-sectional area reduction, is investigated by using numerical fluid dynamics. Two-equation k-ω model is used for the simulation of the transitional flow with Reynolds numbers 500 and 1000. It is found that the spiral component increases the static pressure in the vessel during the deceleration phase of the flow pulse. In addition, the spiral component reduces the turbulence intensity and wall shear stress found in the post-stenosis region of the vessel in the early stages of the flow pulse. Hence, the findings agree with the results of Stonebridge et al. (2004). In addition, the results of the effects of a spiral component on time-varying flow are presented and discussed along with the relevant pathological issues.

  20. Arterialized and venous blood lactate concentration difference during different exercise intensities

    Directory of Open Access Journals (Sweden)

    Leandro C. Felippe

    2017-06-01

    Conclusion: These results suggest a delayed lactate appearance in the venous blood, which is accentuated at higher exercise intensities. The lactate measured in arterialized and venous blood is interchangeable only when blood samples are collected at least 10 minutes after the exercise starts.

  1. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  2. [Ultrasonographic study of blood flow in the renal arteries of patients with arterial hypertension].

    Science.gov (United States)

    Makarenko, E S; Dombrovskiĭ, V I; Nelasov, N Iu

    2012-01-01

    Vascular duplex ultrasound duplex with simultaneous ECG registration was made to estimate the quantitative and time parameters of blood flow in the renal arteries with grade 1-2 arterial hypertension. There were increases in vascular resistance indices and acceleration phase index and a reduction in systolic phase index. There were correlations of the time parameters of blood flow in the renal arteries with age and lipidogram values.

  3. Resting quantitative cerebral blood flow in schizophrenia measured by pulsed arterial spin labeling perfusion MRI

    OpenAIRE

    Pinkham, Amy; Loughead, James; Ruparel, Kosha; Wu, Wen-Chau; Overton, Eve; Gur, Raquel; Gur, Ruben

    2011-01-01

    Arterial spin labeling imaging (ASL) perfusion MRI is a relatively novel technique that can allow for quantitative measurement of cerebral blood flow (CBF) by using magnetically labeled arterial blood water as an endogenous tracer. Available data on resting CBF in schizophrenia primarily comes from invasive and expensive nuclear medicine techniques that are often limited to small samples and yield mixed results. The noninvasive nature of ASL offers promise for larger-scale studies. The utilit...

  4. ABO Blood Group and Risk of Thromboembolic and Arterial Disease

    DEFF Research Database (Denmark)

    Vasan, Senthil K; Rostgaard, Klaus; Majeed, Ammar

    2016-01-01

    BACKGROUND: ABO blood groups have been shown to be associated with increased risks of venous thromboembolic and arterial disease. However, the reported magnitude of this association is inconsistent and is based on evidence from small-scale studies. METHODS AND RESULTS: We used the SCANDAT2...... (Scandinavian Donations and Transfusions) database of blood donors linked with other nationwide health data registers to investigate the association between ABO blood groups and the incidence of first and recurrent venous thromboembolic and arterial events. Blood donors in Denmark and Sweden between 1987......-up. Compared with blood group O, non-O blood groups were associated with higher incidence of both venous and arterial thromboembolic events. The highest rate ratios were observed for pregnancy-related venous thromboembolism (incidence rate ratio, 2.22; 95% confidence interval, 1.77-2.79), deep vein thrombosis...

  5. Cluster analysis in kinetic modelling of the brain: A noninvasive alternative to arterial sampling

    DEFF Research Database (Denmark)

    Liptrot, Matthew George; Adams, K.H.; Martiny, L.

    2004-01-01

    In emission tomography, quantification of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling. We propose a noninvasive alternative via the use of a blood vessel time-activity curve (TAC....... © 2003 Elsevier Inc. All rights reserved....

  6. Improved calculation of the equilibrium magnetization of arterial blood in arterial spin labeling

    DEFF Research Database (Denmark)

    Ahlgren, André; Wirestam, Ronnie; Knutsson, Linda

    2018-01-01

    PURPOSE: To propose and assess an improved method for calculating the equilibrium magnetization of arterial blood ( M0a), used for calibration of perfusion estimates in arterial spin labeling. METHODS: Whereas standard M0a calculation is based on dividing a proton density-weighted image by an ave...

  7. [Prognostic Doppler ultrasound examination of fetal arteries blood flow].

    Science.gov (United States)

    Sieroszewski, Piotr; Sabatowska, Małgorzata; Karowicz-Bilińska, Agata; Suzin, Jacek

    2002-08-01

    Early detection of fetal risk is one of the main issues in today obstetrics. Ultrasound diagnostics plays a significant role, as the introduction of Doppler imaging method in the evaluation of blood flow has enabled non-invasive assessment of uteroplacental circulation. Therefore, we have analysed foetal three arteries: umbilical artery, middle cerebral artery and renal artery after determining the normal range for the analysed parameters. 1. Comparison of the obtained blood flow indices (S/D, RI, PI) in the umbilical artery, middle cerebral artery and renal artery of foetuses from normal and complicated full-term pregnancies. 2. Determination of indices: umbilical-cerebral and renal-cerebral in normal and pathological pregnancy. 3. Evaluation of feasibility of the analysed flow parameters for the detection of intrauterine foetal hypoxia. We have examined 151 women, who were divided into control group--101 pregnant women with normal pregnancy and study group--50 pregnant women with complicated pregnancy. All pregnant women underwent ultrasound examination using the Hitachi EUB 515 C (Japan) scanner with 3.5 MHz convex probe, connected to the colour pulsed Doppler. The study consisted of the biometric measurements and evaluation of the spectrum of blood flow in the umbilical artery, middle cerebral artery and renal artery. We have determined following indices: a) systolic-diastolic ratio S/D, resistance index RI, pulsatility index PI, b) umbilical-cerebral ratio P/M. (PI ua/PI mca), renal--cerebral ratio N/M (PI ra/PI mca). Statistically significant difference was found between the study and control groups for all the flow indices assessed (S/D, RI, PI) for the middle cerebral artery, for the indices P/M and N/M. (p < 0.001) and pulsatility index in the renal artery (p < 0.01). Similar, although slightly smaller difference (p < 0.05) was seen for the values of flow parameters in the umbilical artery. 1) Evaluation of blood flow in the middle cerebral artery, and in

  8. The relationship between total arterial revascularization and blood transfusion following coronary artery bypass grafting.

    Science.gov (United States)

    Djordjevic, Jasmina; Ngaage, Dumbor L

    2015-05-01

    Blood transfusion adversely affects the outcome of coronary artery bypass grafting (CABG), yet blood transfusion after CABG is still common. Total arterial revascularisation (TAR) is increasingly used in current practice but its impact on postoperative blood transfusion is not known. We reviewed the cardiothoracic and blood bank databases and collected data for isolated primary CABG patients from July 2007 to June 2012, excluding patients who had a single graft (n = 148). Perioperative variables of TAR patients (n = 745) were compared with patients who had one or more venous grafts (SVG, n = 1,761) for first-time isolated CABG. The conduits used in TAR patients were predominantly left internal thoracic and radial arteries. Matched group comparison of TAR and SVG patients was performed. The association of TAR with blood transfusion was investigated using multivariate and matched analysis. Of 2,506 patients, the 745 (29.7 %) that had TAR were generally younger, with less complex coronary artery disease and less often diabetic. After correcting for these by 1:1 matching, the mean chest tube drainage and rates of blood transfusion remained significantly lower (p transfused in TAR patients. By multivariate analysis, TAR had an independent effect on reducing blood transfusion after CABG [odds ratio (OR) 0.67, 95 % confidence interval (CI) 0.47-0.97, p = .03]. TAR achieved predominantly with left internal thoracic and radial arteries substantially reduced blood transfusion rates after primary CABG. Further studies are warranted.

  9. Biochemical characterization of blood plasma of coronary artery ...

    Indian Academy of Sciences (India)

    This study aimed to investigate the biochemical profile of blood plasma of patients with coronary artery disease (CAD) and angiographically normal subjects (controls) to determine biomarkers for their differentiation. In this double blind study, 5 mL venous blood was drawn before angiography from CAD patients (n=60) and ...

  10. Blood flows in the maxillocarotid anastomoses and internal carotid artery of conscious dogs.

    Science.gov (United States)

    Lee, M C; Reid, I A; Ramsay, D J

    1986-06-01

    Although the external carotid artery is known to contribute to the cerebral blood flow in anesthetized dogs, quantitative information on the anastomoses and their role in conscious dogs is lacking. This study was carried out to determine blood flows in these anastomoses and the internal carotid artery, and also to examine the functional significance of the anastomoses in conscious dogs. Fifteen-micron radioactive microspheres were injected into common and external carotid arteries of four conscious dogs through chronically implanted catheters. Blood flows were determined by the reference sample method and by comparing microsphere distributions in the brain and the masseter muscle. Blood flows were estimated to be 140 +/- 32, 7.7 +/- 1.4, and 3.3 +/- 1.1 ml/minute (mean +/- SD) in the common carotid artery, internal carotid artery, and anastomoses on each side, respectively. Additional evidence indicated that the anastomotic flow so determined was primarily the flow in the anastomotic artery. Humoral responses to angiotensin II infusions were also studied in conscious dogs. External carotid angiotensin increased plasma 11-hydroxycorticosteroid concentration (used as an index of ACTH secretion) but did not increase plasma vasopressin concentration to the same extent as common carotid infusion. Therefore, the external carotid artery is functionally important in perfusing the brain in conscious dogs.

  11. Distribution of ABO Blood Groups and Coronary Artery Calcium.

    Science.gov (United States)

    Wang, Yao; Zhou, Bing-Yang; Zhu, Cheng-Gang; Guo, Yuan-Lin; Wu, Na-Qiong; Qing, Ping; Gao, Ying; Liu, Geng; Dong, Qian; Li, Jian-Jun

    2017-06-01

    ABO blood groups have been confirmed to be associated with cardiovascular diseases such as coronary artery disease. However, whether ABO blood group is correlated with coronary artery calcium (CAC) is still unknown. 301 patients with coronary artery calcium score (CACS) assessed by computed tomography were consecutively enrolled and divided into two groups: with calcium group (CACS>0, n=104) and without calcium group (CACS=0, n=197). Distribution of ABO blood groups was evaluated between the two groups. The percentage of A blood type was significantly higher (p=0.008) and O blood type was significantly lower (p=0.037) in the calcium group. Univariate regression analysis showed that age, total cholesterol, low density lipoprotein cholesterol, high-sensitivity C-reactive protein, A blood type were positively correlated with CAC, and O blood type was inversely associated with CAC. Multivariate regression analysis showed that A blood type was independently associated with CAC (odds ratio: 2.217, 95% confidence interval: 1.260-3.900, p=0.006) even after further adjustment for variables that were clearly different between the two groups. Our data has suggested for the first time that A blood type was an independent risk marker for CAC. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  12. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Agnes S. Meidert

    2018-01-01

    Full Text Available Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent or continuous readings. Most commonly, an occluding upper arm cuff is used for intermittent non-invasive monitoring. BP values are then obtained either manually (by auscultation of Korotkoff sounds or palpation or automatically (e.g., by oscillometry. For continuous non-invasive BP monitoring, the volume clamp method or arterial applanation tonometry can be used. Both techniques enable the arterial waveform and BP values to be obtained continuously. This article describes the different techniques for non-invasive BP measurement, their advantages and limitations, and their clinical applicability.

  13. WE-FG-206-05: New Arterial Spin Labeling Method for Simultaneous Estimation of Arterial Cerebral Blood Volume, Cerebral Blood Flow and Arterial Transit Time

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, M; Whitlow, C; Jung, Y [Wake Forest School of Medicine, Winston-Salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel Arterial Spin Labeling (ASL) method for simultaneously measuring cerebral blood flow (CBF), arterial transit time (ATT), and arterial cerebral blood volume (aCBV) without the use of a contrast agent. Methods: A series of multi-TI ASL images were acquired from one healthy subject on a 3T Siemens Skyra, with the following parameters: PCASL labeling with variable TI [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms, labeling bolus 1400 ms when TI allows, otherwise 100 ms less than TI, TR was minimized for each TI, two sinc shaped pre-saturation pulses were applied in the imaging plane immediately before 2D EPI acquisition. 64×64×24 voxels, 5 mm slice thickness, 1 mm gap, full brain coverage, 6 averages per TI, no crusher gradients, 11 ms TE, scan time of 4:56. The perfusion weighted time-series was created for each voxel and fit to a novel model. The model has two components: 1) the traditional model developed by Buxton et al., accounting for CBF and ATT, and 2) a box car function characterizing the width of the labeling bolus, with variable timing and height in proportion to the aCBV. All three parameters were fit using a nonlinear fitting routine that constrained all parameters to be positive. The main purpose of the high-temporal resolution TI sampling for the first second of data acquisition was to precisely estimate the blood volume component for better detection of arrival time and magnitude of signal. Results: Whole brain maps of CBF, ATT, and aCBV were produced, and all three parameters maps are consistent with similar maps described in the literature. Conclusion: Simultaneous mapping of CBF, ATT, and aCBV is feasible with a clinically tractable scan time (under 5 minutes).

  14. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P blood pressure and HR from daytime...

  15. Evaluation of arterial blood gases and arterial blood pressures in brachycephalic dogs.

    Science.gov (United States)

    Hoareau, G L; Jourdan, G; Mellema, M; Verwaerde, P

    2012-01-01

    Brachycephalic dogs (BD) are prone to congenital upper airway obstruction (brachycephalic syndrome, BS). In humans suffering from sleep apnea, upper airway obstruction is known to cause hypertension. There is no information regarding the influence of BS in dogs on cardiorespiratory physiology. BD are prone to lower P(a) O(2), higher P(a) CO (2), and hypertension compared with meso- or dolicocephalic dogs (MDD). Eleven BD and 11 MDD. After a questionnaire was completed by the owner, a physical examination was performed. Height and thoracic circumferences were measured. Arterial blood gases, electrolyte concentrations, and packed cell volume (PCV) were measured. Systolic (SAP), mean (MAP), and diastolic (DAP) arterial blood pressure recordings were performed. A total of 7 French and 4 English bulldogs met the inclusion criteria. The control group consisted in 6 Beagles, 2 mixed breed dogs, 1 Staffordshire Bull Terrier, 1 Parson Russell Terrier, and 1 Australian Cattle Dog. Statistically, BD had lower P(a) O(2), higher P(a) CO2, and higher PCV when compared with controls (86.2 ± 15.9 versus 100.2 ± 12.6 mmHg, P = .017; 36.3 ± 4.6 versus 32.7 ± 2.6 mmHg, P = .019; 48.2 ± 3.5 versus 44.2 ± 5.4%, P = .026, respectively). Also, they had significantly higher SAP (177.6 ± 25.0 versus 153.5 ± 21.7 mmHg, P = .013), MAP (123.3 ± 17.1 versus 108.3 ± 12.2 mmHg, P = .014), and DAP (95.3 ± 19.2 versus 83.0 ± 11.5 mmHg, P = .042). BD with a P(a) CO (2) >35 mmHg were significantly older than those with a P(a) CO (2) ≤35 mmHg (58 ± 16 and 30 ± 11 months, P = .004). Results of this study suggest that some BD are prone to lower P(a) O(2), higher P(a) CO (2), and hypertension when compared with MDD. Age may be a contributing factor. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  16. Neonatal oxidative stress depends on oxygen blood pressure in umbilical artery.

    Science.gov (United States)

    Proietti, F; De Bernardo, G; Longini, M; Sordino, D; Scaramuzzini, G; Tataranno, M L; Belvisi, E; Bazzini, F; Perrone, S; Buonocore, G

    2016-01-01

    With advancing gestation, partial pressure of oxygen (pO2) and pH fall significantly. Hypoxia is a main factor inducing free radical generation and thereby oxidative stress (OS). Placental and fetal tissue response when oxygen becomes restricted is complex and partially known. We tested the hypothesis that changes in umbilical artery and vein blood gas concentrations modulate OS occurrence in the newborn. Seventy umbilical artery and vein plasma samples were collected from healthy term newborns immediately after delivery. F2 Isoprostanes (F2-Isop) were measured in all samples as reliable markers of lipid peroxidation. Significantly lower pCO2 and higher pO2 and pH were found in umbilical vein than in artery, as expected. A positive correlation was detected between pH and pO2 only in umbilical artery (p=0.019). F2-Isop levels were no different between artery and vein in cord blood. Significant correlations were found between F2-Isop and pCO2 (p=0.025) as well as between F2-Isop and pH in umbilical vein (p=0.027). F2-Isop correlated with pCO2 (p=0.007) as well as with pO2 values (p=0.005) in umbilical artery blood. Oxidative stress (OS) in newborns depends on oxygen concentrations in umbilical artery. OS biomarkers significantly correlate with pO2 and in umbilical artery but not in umbilical vein. In normoxic conditions fetal-maternal gas exchanges occurring in placenta re-establish normal higher oxygen levels in umbilical vein than artery, with a normal production of free radicals without any deleterious effects.

  17. Blood sampling from adrenal gland vein

    International Nuclear Information System (INIS)

    Sun Yong; Ni Caifang

    2009-01-01

    Adrenal gland vein sampling is an interventional method to get the blood samples from the adrenal gland vein. The blood is obtained via a catheter which is selectively inserted in the adrenal gland vein. This technique is mainly used to be diagnostic for primary hyperaldosteronism. A full knowledge of the anatomy and variations of the adrenal gland vein, serious preoperative preparation and skilled catheterization manipulation are necessary for obtaining sufficient blood sample and for reducing the occurrence of complications. Providing the physicians with definite diagnostic evidence and being technically feasible, adrenal gland vein sampling should become one of the routine examinations for clarifying the cause of primary hyperaldosteronism. (authors)

  18. Non Newtonian Behavior of Blood in Presence of Arterial Occlusion

    OpenAIRE

    Dr.Arun Kumar Maiti

    2016-01-01

    The objective of the present numerical model is to investigate the effect of shape of stenosis on blood flow through an artery using Bingham plastic fluid model. Blood is modeled as Bingham plastic fluid in a uniform circular tube with an axially symmetric but radially non symmetric stenosis. The expressions for flux, dimensionless resistance to flow with stenosis shape parameter, stenosis length and stenosis size have been shown graphically

  19. Tale of two sites: capillary versus arterial blood glucose testing in the operating room.

    Science.gov (United States)

    Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O

    2012-04-01

    Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a

  20. Implantable blood pressure sensor for analyzing elasticity in arteries

    Science.gov (United States)

    Franco-Ayala, Marco; Martínez-Piñón, Fernando; Reyes-Barranca, Alfredo; Sánchez de la Peña, Salvador; Álvarez-Chavez, José A.

    2009-03-01

    MEMS technology could be an option for the development of a pressure sensor which allows the monitoring of several electronic signals in humans. In this work, a comparison is made between the typical elasticity curves of several arteries in the human body and the elasticity obtained for MEMS silicon microstructures such as membranes and cantilevers employing Finite Element analysis tools. The purpose is to identify which types of microstructures are mechanically compatible with human arteries. The goal is to integrate a blood pressure sensor which can be implanted in proximity with an artery. The expected benefits for this type of sensor are mainly to reduce the problems associated with the use of bulk devices through the day and during several days. Such a sensor could give precise blood pressure readings in a continuous or periodic form, i.e. information that is especially important for some critical cases of hypertension patients.

  1. Nocturnal foot blood flow in patients with arterial insufficiency

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Tønnesen, K H

    1984-01-01

    Twenty-four hour continuous recording of xenon (133Xe) wash-out from the forefoot was performed on patients with normal circulations (n = 10) and on patients with different degrees of arterial insufficiency (n = 36). During day hours the calculated subcutaneous blood flow in the forefoot was on a...

  2. Preanalytical Blood Sampling Errors in Clinical Settings

    International Nuclear Information System (INIS)

    Zehra, N.; Malik, A. H.; Arshad, Q.; Sarwar, S.; Aslam, S.

    2016-01-01

    Background: Blood sampling is one of the common procedures done in every ward for disease diagnosis and prognosis. Daily hundreds of samples are collected from different wards but lack of appropriate knowledge of blood sampling by paramedical staff and accidental errors make the samples inappropriate for testing. Thus the need to avoid these errors for better results still remains. We carried out this research with an aim to determine the common errors during blood sampling; find factors responsible and propose ways to reduce these errors. Methods: A cross sectional descriptive study was carried out at the Military and Combined Military Hospital Rawalpindi during February and March 2014. A Venous Blood Sampling questionnaire (VBSQ) was filled by the staff on voluntary basis in front of the researchers. The staff was briefed on the purpose of the survey before filling the questionnaire. Sample size was 228. Results were analysed using SPSS-21. Results: When asked in the questionnaire, around 61.6 percent of the paramedical staff stated that they cleaned the vein by moving the alcohol swab from inward to outwards while 20.8 percent of the staff reported that they felt the vein after disinfection. On contrary to WHO guidelines, 89.6 percent identified that they had a habit of placing blood in the test tube by holding it in the other hand, which should actually be done after inserting it into the stand. Although 86 percent thought that they had ample knowledge regarding the blood sampling process but they did not practice it properly. Conclusion: Pre analytical blood sampling errors are common in our setup. Eighty six percent participants though thought that they had adequate knowledge regarding blood sampling, but most of them were not adhering to standard protocols. There is a need of continued education and refresher courses. (author)

  3. Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree

    International Nuclear Information System (INIS)

    Molloi, Sabee; Wong, Jerry T

    2007-01-01

    The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 er relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data

  4. Fetal scalp blood sampling during labor

    DEFF Research Database (Denmark)

    Chandraharan, Edwin; Wiberg, Nana

    2014-01-01

    Fetal cardiotocography is characterized by low specificity; therefore, in an attempt to ensure fetal well-being, fetal scalp blood sampling has been recommended by most obstetric societies in the case of a non-reassuring cardiotocography. The scientific agreement on the evidence for using fetal...... scalp blood sampling to decrease the rate of operative delivery for fetal distress is ambiguous. Based on the same studies, a Cochrane review states that fetal scalp blood sampling increases the rate of instrumental delivery while decreasing neonatal acidosis, whereas the National Institute of Health...... and Clinical Excellence guideline considers that fetal scalp blood sampling decreases instrumental delivery without differences in other outcome variables. The fetal scalp is supplied by vessels outside the skull below the level of the cranial vault, which is likely to be compressed during contractions...

  5. Parameters of Blood Flow in Great Arteries in Hypertensive ISIAH Rats with Stress-Dependent Arterial Hypertension.

    Science.gov (United States)

    Seryapina, A A; Shevelev, O B; Moshkin, M P; Markel', A L

    2016-08-01

    Magnetic resonance angiography was used to examine blood flow in great arteries of hypertensive ISIAH and normotensive Wistar rats. In hypertensive ISIAH rats, increased vascular resistance in the basin of the abdominal aorta and renal arteries as well as reduced fraction of total renal blood flow were found. In contrast, blood flow through both carotid arteries in ISIAH rats was enhanced, which in suggests more intensive blood supply to brain regulatory centers providing enhanced stress reactivity of these rats characterized by stress-dependent arterial hypertension.

  6. Vasoactive enzymes and blood flow responses to passive and active exercise in peripheral arterial disease

    DEFF Research Database (Denmark)

    Walker, Meegan A.; Høier, Birgitte; Walker, Philip J.

    2016-01-01

    Background: Peripheral arterial disease (PAD) is characterised by impaired leg blood flow, which contributes to claudication and reduced exercise capacity. This study investigated to what extent vasoactive enzymes might contribute to altered blood flow in PAD (Fontaine stage II). Methods: We...... compared femoral artery blood flow during reactive hyperaemia, leg-extension exercise and passive leg movement, and determined the level of vasoactive enzymes in skeletal muscle samples from the vastus lateralis in PAD (n = 10, 68.5 ± 6.5 years) and healthy controls (CON, n = 9, 62.1 ± 12.3 years). Leg...... than CON (1.04 ± 0.19 vs 0.50 ± 0.06 AU, P = 0.02), with no differences for other enzymes. Leg blood flow during exercise was correlated with prostacyclin synthase (P = 0.001). Conclusion: Elevated NADPH oxidase indicates that oxidative stress may be a primary cause of low nitric oxide availability...

  7. 21 CFR 870.4260 - Cardiopulmonary bypass arterial line blood filter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass arterial line blood filter... Cardiopulmonary bypass arterial line blood filter. (a) Identification. A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic...

  8. Predicting Electrocardiogram and Arterial Blood Pressure Waveforms with Different Echo State Network Architectures

    Science.gov (United States)

    2014-11-01

    Predicting Electrocardiogram and Arterial Blood Pressure Waveforms with Different Echo State Network Architectures Allan Fong, MS1,3, Ranjeev...the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the...type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network

  9. The relationship between blood viscosity and blood pressure in a random sample of the population aged 55 to 74 years.

    Science.gov (United States)

    Fowkes, F G; Lowe, G D; Rumley, A; Lennie, S E; Smith, F B; Donnan, P T

    1993-05-01

    Blood viscosity is elevated in hypertensive subjects, but the association of viscosity with arterial blood pressure in the general population, and the influence of social, lifestyle and disease characteristics on this association, are not established. In the Edinburgh Artery Study, 1592 men and women aged 55-74 years selected randomly from the general population attended a university clinic. A fasting blood sample was taken for the measurement of blood viscosity and its major determinants (haematocrit, plasma viscosity and fibrinogen). Systolic pressure was related univariately to blood viscosity (P viscosity (P index. Diastolic pressure was related univariately to blood viscosity (P viscosity (P viscosity and systolic pressure was confined to males. Blood viscosity was associated equally with systolic and diastolic pressures in males, and remained independently related on multivariate analysis adjusting for age, sex, body mass index, social class, smoking, alcohol intake, exercise, angina, HDL and non-HDL cholesterol, diabetes mellitus, plasma viscosity, fibrinogen, and haematocrit.

  10. Queixa de vertigem e hipertensão arterial Vertigo complaint and blood hypertension

    Directory of Open Access Journals (Sweden)

    Luciana Lozza de Moraes Marchiori

    2007-03-01

    Full Text Available OBJETIVO: investigar a presença de queixa de vertigem em pacientes de meia idade com hipertensão arterial. MÉTODOS: estudo do tipo prospectivo, transversal. Composto por 154 indivíduos de ambos os gêneros com idade de 45 a 64 anos. A hipertensão foi verificada por meio de medição da pressão arterial e de questionário sistematizado sobre hipertensão e uso de medicamentos para pressão arterial. A queixa de vertigem foi verificada por meio de anamnese audiológica. RESULTADOS: pode-se verificar que existe associação significante entre hipertensão arterial e queixa de vertigem. CONCLUSÃO: os resultados da presente pesquisa, por meio da constatação da associação entre hipertensão arterial e queixa de vertigem, servirão de base a profissionais da área de saúde que estão envolvidos com sintomas provenientes da hipertensão arterial.PURPOSE: to investigate the presence of vertigo complaint in middle-aged hypertension patients. METHODS: a transversal study. Composed by 154 patients of both genders, aged from 45 to 64 years, included in the research after sample estimation. Hypertension was verified through blood pressure readings and by a systematized questionnaire about hypertension and the use of medication for blood pressure. Vertigo was assessed through audiological anamneses. RESULTS: there is a significant association between blood hypertension and vertigo. CONCLUSION: the results in this research, through evidence of association between blood hypertension and vertigo complaint, can be a base for health professionals concerned with alterations caused by blood hypertension.

  11. The measurement of blood speed in the pulmonary artery trunk

    Energy Technology Data Exchange (ETDEWEB)

    Saro, J P; Bula-Cruz, J [UTAD - 5000 Vila Real (Spain); Rafael, J A [Dep. Electronica e Telecomunicacoes da Univ. de Aveiro - 3800 Aveiro (Spain); Botelho, M F; Lima, J P [IBILI - Faculdade de Medicina da Univ. de Coimbra - 3000 Coimbra (Spain)

    1999-12-31

    The paper describes a non invasive methodology for the measurement of blood speed in the pulmonary artery trunk. The methodology has been tested with a moving radioactive tracer (nuclear medicine). An image processing technique is proposed, for detection and analysis of a moving object with variable shape and intensity over time (radioactive bolus). Experiments on the application of the technique in nuclear medicine are critically analysed. (authors) 9 refs., 7 figs.

  12. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Meindl, J. D.

    1975-01-01

    An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

  13. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    International Nuclear Information System (INIS)

    Kyriacou, P A; Shafqat, K; Pal, S K

    2007-01-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO 2 ) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO 2 ) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO 2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  14. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Shafqat, K [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Pal, S K [St Andrew' s Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, CM1 7ET (United Kingdom)

    2007-10-15

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO{sub 2}) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO{sub 2}) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO{sub 2} sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures

  15. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Science.gov (United States)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  16. The conundrum of arterial stiffness, elevated blood pressure, and aging.

    Science.gov (United States)

    AlGhatrif, Majd; Lakatta, Edward G

    2015-02-01

    Isolated systolic hypertension is a major health burden that is expanding with the aging of our population. There is evidence that central arterial stiffness contributes to the rise in systolic blood pressure (SBP); at the same time, central arterial stiffening is accelerated in patients with increased SBP. This bidirectional relationship created a controversy in the field on whether arterial stiffness leads to hypertension or vice versa. Given the profound interdependency of arterial stiffness and blood pressure, this question seems intrinsically challenging, or probably naïve. The aorta's function of dampening the pulsatile flow generated by the left ventricle is optimal within a physiological range of distending pressure that secures the required distal flow, keeps the aorta in an optimal mechanical conformation, and minimizes cardiac work. This homeostasis is disturbed by age-associated, minute alterations in aortic hemodynamic and mechanical properties that induce short- and long-term alterations in each other. Hence, it is impossible to detect an "initial insult" at an epidemiological level. Earlier manifestations of these alterations are observed in young adulthood with a sharp decline in aortic strain and distensibility accompanied by an increase in diastolic blood pressure. Subsequently, aortic mechanical reserve is exhausted, and aortic remodeling with wall stiffening and dilatation ensue. These two phenomena affect pulse pressure in opposite directions and different magnitudes. With early remodeling, there is an increase in pulse pressure, due to the dominance of arterial wall stiffness, which in turn accelerates aortic wall stiffness and dilation. With advanced remodeling, which appears to be greater in men, the effect of diameter becomes more pronounced and partially offsets the effect of wall stiffness leading to plateauing in pulse pressure in men and slower increase in pulse pressure (PP) than that of wall stiffness in women. The complex nature of

  17. PREDICTION OF BLOOD PATTERN IN S-SHAPED MODEL OF ARTERY UNDER NORMAL BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    Mohd Azrul Hisham Mohd Adib

    2013-06-01

    Full Text Available Athletes are susceptible to a wide variety of traumatic and non-traumatic vascular injuries to the lower limb. This paper aims to predict the three-dimensional flow pattern of blood through an S-shaped geometrical artery model. This model has created by using Fluid Structure Interaction (FSI software. The modeling of the geometrical S-shaped artery is suitable for understanding the pattern of blood flow under constant normal blood pressure. In this study, a numerical method is used that works on the assumption that the blood is incompressible and Newtonian; thus, a laminar type of flow can be considered. The authors have compared the results with a previous study with FSI validation simulation. The validation and verification of the simulation studies is performed by comparing the maximum velocity at t = 0.4 s, because at this time, the blood accelerates rapidly. In addition, the resulting blood flow at various times, under the same boundary conditions in the S-shaped geometrical artery model, is presented. The graph shows that velocity increases linearly with time. Thus, it can be concluded that the flow of blood increases with respect to the pressure inside the body.

  18. Blood Sample Transportation by Pneumatic Transportation Systems

    DEFF Research Database (Denmark)

    Nybo, Mads; Lund, Merete E; Titlestad, Kjell

    2018-01-01

    BACKGROUND: Pneumatic transportation systems (PTSs) are increasingly used for transportation of blood samples to the core laboratory. Many studies have investigated the impact of these systems on different types of analyses, but to elucidate whether PTSs in general are safe for transportation...... analysis, and the hemolysis index). CONCLUSIONS: Owing to their high degree of heterogeneity, the retrieved studies were unable to supply evidence for the safety of using PTSs for blood sample transportation. In consequence, laboratories need to measure and document the actual acceleration forces...

  19. Research results: preserving newborn blood samples.

    Science.gov (United States)

    Lewis, Michelle Huckaby; Scheurer, Michael E; Green, Robert C; McGuire, Amy L

    2012-11-07

    Retention and use, without explicit parental permission, of residual dried blood samples from newborn screening has generated public controversy over concerns about violations of family privacy rights and loss of parental autonomy. The public debate about this issue has included little discussion about the destruction of a potentially valuable public resource that can be used for research that may yield improvements in public health. The research community must advocate for policies and infrastructure that promote retention of residual dried blood samples and their use in biomedical research.

  20. Arterial blood gas reference values for sea level and an altitude of 1,400 meters.

    Science.gov (United States)

    Crapo, R O; Jensen, R L; Hegewald, M; Tashkin, D P

    1999-11-01

    Blood gas measurements were collected on healthy lifetime nonsmokers at sea level (n = 96) and at an altitude of 1,400 meters (n = 243) to establish reference equations. At each study site, arterial blood samples were analyzed in duplicate on two separate blood gas analyzers and CO-oximeters. Arterial blood gas variables included Pa(O(2)), Pa(CO(2)), pH, and calculated alveolar-arterial PO(2) difference (AaPO(2)). CO-oximeter variables were Hb, COHb, MetHb, and Sa(O(2)). Subjects were 18 to 81 yr of age with 166 male and 173 female. Outlier data were excluded from multiple regression analysis, and reference equations were fitted to the data in two ways: (1) best fit using linear, squared, and cross-product terms; (2) simple equations, including only the variables that explained at least 3% of the variance. Two sets of equations were created: (1) using only the sea level data and (2) using the combined data with barometric pressure as an independent variable. Comparisons with earlier studies revealed small but significant differences; the decline in Pa(O(2)) with age at each altitude was consistent with most previous studies. At sea level, the equation that included barometric pressure predicted Pa(O(2)) slightly better than the sea level specific equation. The inclusion of barometric pressure in the equations allows better prediction of blood gas reference values at sea level and at altitudes as high as 1,400 meters.

  1. Improving blood sample logistics using simulation

    DEFF Research Database (Denmark)

    Jørgensen, Pelle Morten Thomas; Jacobsen, Peter

    2012-01-01

    Using simulation as an approach to display and improve internal logistics and handling at hospitals has great potential. This research will show how a simulation model can be used to evaluate changes made to two different cases of transportation of blood samples at a hospital, by evaluating...

  2. Dopexamine increases internal mammary artery blood flow following coronary artery bypass grafting.

    LENUS (Irish Health Repository)

    Flynn, Michael J

    2012-02-03

    OBJECTIVE: Vasoactive agents and inotropes influence conduit-coronary blood flow following coronary artery bypass grafting (CABG). It was hypothesized that dopexamine hydrochloride, a dopamine A-1 (DA-1) and beta(2) agonist would increase conduit-coronary blood flow. A prospective randomized double blind clinical trial was carried out to test this hypothesis. DA-1 receptors have previously been localized to human left ventricle. METHODS: Twenty-six American Society of Anaesthesiology class 2-3 elective coronary artery bypass graft patients who did not require inotropic support on separation from cardiopulmonary bypass (CPB) were studied. According to a randomized allocation patients received either dopexamine (1 microg\\/kg per min) or placebo (saline) by intravenous infusion for 15 min. Immediately prior to and at 5,10 and 15 min of infusion, blood flow through the internal mammary and vein grafts (Transit time flow probes, Transonic Ltd.), heart rate, cardiac index, mean arterial pressure and pulmonary haemodynamics were noted. The data were analysed using multivariate analysis of variance. RESULTS: Low-dose dopexamine (1 microg\\/kg per min) caused a significant increase in mammary graft blood flow compared to placebo at 15 min of infusion (P=0.028, dopexamine group left internal mammary artery (LIMA) flow of 43.3+\\/-14.2 ml\\/min, placebo group LIMA flow at 26.1+\\/-16.3 ml\\/min). Dopexamine recipients demonstrated a non-significant trend to increased saphenous vein graft flow (P=0.059). Increased heart rate was the only haemodynamic change induced by dopexamine (P=0.004, dopexamine group at 85.2+\\/-9.6 beats\\/min and placebo group at 71.1+\\/-7.6 beats\\/min after 15 min of infusion). CONCLUSION: This study demonstrates that administration of dopexamine (1 microg\\/kg per min) was associated with a significant increase in internal mammary artery graft blood flow with mild increase in heart rate being the only haemodynamic change. Low-dose dopexamine may

  3. Evaluation of Blood Hemodynamics in Vascular Grafts after Total Arterial Coronary Revascularization

    Directory of Open Access Journals (Sweden)

    Ahmad Ali Amirghofran

    2016-07-01

    Full Text Available Arterial grafting has increasingly been advocated for the treatment of coronary artery disease in an attempt to improve the long-term results. In the quest to perform routine total arterial revascularization, composite Y graft methods are gaining popularity. The aim of our study was to evaluate whether blood flow in the left internal thoracic artery can provide sufficient perfusion to the entire cardiac muscle per se. Twenty patients with severe coronary artery stenosis who underwent complete arterial coronary revascularization using a composite graft entered our study. Blood flow in thoracic trunk was evaluated in three phases: cross-clamp on, cross-clamp off, and after weaning the patient from cardiopulmonary bypass. Mean arterial blood pressure in the thoracic trunk in these various positions was 62.7±3.7. left internal thora cic artery can provide sufficient blood flow to the cardiac muscles for both rest and exercise conditions.

  4. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography.

    Science.gov (United States)

    Yu, Zaitao; Shi, Xiang'en; Brohi, Shams Raza; Qian, Hai; Liu, Fangjun; Yang, Yang

    2017-02-01

    This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures. © 2016 by the American Institute of Ultrasound in Medicine.

  5. Effects of feeding on arterial blood gases in the American alligator Alligator mississippiensis.

    Science.gov (United States)

    Busk, M; Overgaard, J; Hicks, J W; Bennett, A F; Wang, T

    2000-10-01

    Reptiles habitually ingest large meals at infrequent intervals, leading to changes in acid-base status as the net secretion of acid to the stomach causes a metabolic alkalosis (the alkaline tide). In chronically cannulated and undisturbed amphibians and reptiles, the pH changes in arterial blood are, nevertheless, reduced by a concomitant respiratory acidosis (increased P(CO2) caused by a relative hypoventilation). Alligators (Alligator mississippiensis) have been reported to exhibit exceptionally large increases in plasma [HCO3(-)] following feeding, but these studies were based on blood samples obtained by cardiac puncture, so stress and disturbance may have affected the blood gas levels. Furthermore, crocodilian haemoglobin is characterised by a unique binding of HCO3(-) that act to reduce blood oxygen-affinity, and it has been proposed that this feature safeguards oxygen offloading by counteracting pH effects on blood oxygen-affinity. Therefore, to study acid-base regulation and the interaction between the alkaline tide and oxygen transport in more detail, we describe the arterial blood gas composition of chronically cannulated and undisturbed alligators before and after voluntary feeding (meal size 7.5+/-1% of body mass). Digestion was associated with an approximately fourfold increase in metabolic rate (from 0.63+/-0.04 to 2.32+/-0.24 ml O(2) min(-1)kg(-1)) and was accompanied by a small increase in the respiratory gas exchange ratio. The arterial P(O2) of fasting alligators was 60.3+/-6.8 mmHg (1 mmHg = 0.133 kPa) and reached a maximum of 81.3+/-2.7 mmHg at 96 h following feeding; there was only a small increase in lactate levels, so the increased metabolic rate seems to be entirely aerobic. Plasma [HCO3(-)] increased from 24.4+/-1.1 to 36.9+/-1.7 mmol l(-1) (at 24 h), but since arterial P(CO2) increased from 29.0+/-1.1 to 36.8+/-1.3 mmHg, arterial pH remained virtually unaffected (changing from 7.51+/-0.01 to 7.58+/-0.01 at 24 h). The changes in plasma [HCO

  6. Intraspecific scaling of arterial blood pressure in the Burmese python.

    Science.gov (United States)

    Enok, Sanne; Slay, Christopher; Abe, Augusto S; Hicks, James W; Wang, Tobias

    2014-07-01

    Interspecific allometric analyses indicate that mean arterial blood pressure (MAP) increases with body mass of snakes and mammals. In snakes, MAP increases in proportion to the increased distance between the heart and the head, when the heart-head vertical distance is expressed as ρgh (where ρ is the density of blood, G: is acceleration due to gravity and h is the vertical distance above the heart), and the rise in MAP is associated with a larger heart to normalize wall stress in the ventricular wall. Based on measurements of MAP in Burmese pythons ranging from 0.9 to 3.7 m in length (0.20-27 kg), we demonstrate that although MAP increases with body mass, the rise in MAP is merely half of that predicted by heart-head distance. Scaling relationships within individual species, therefore, may not be accurately predicted by existing interspecific analyses. © 2014. Published by The Company of Biologists Ltd.

  7. Middle cerebral artery thrombosis: acute blood-brain barrier consequences

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, W.D.; Prado, R.; Watson, B.D.; Nakayama, H.

    1988-07-01

    The effect of middle cerebral artery (MCA) thrombosis on the integrity of the blood-brain barrier (BBB) was studied in rats using horseradish peroxidase (HRP). Endothelial injury with subsequent platelet thrombosis was produced by means of a rose bengal-sensitized photochemical reaction, facilitated by irradiating the right proximal MCA segment with the focused beam of an argon laser. At 15 minutes following thrombosis formation, diffuse leakage of HRP was observed bilaterally within cortical and subcortical brain areas. Peroxidase extravasation was most dense within the territory of the occluded artery including neocortical areas and dorso-lateral striatum. Contralaterally, a similar distribution was observed but with less intense HRP leakage. Ultrastructural studies demonstrated an increase in permeability to HRP within arterioles, venules and capillaries. At these sites, the vascular endothelium contained HRP-filled pinocytotic vesicles and tubular profiles. Although less intense, bilateral HRP leakage was also observed following MCA stenosis or femoral artery occlusion. Endothelial-platelet interactions at the site of vascular injury may be responsible for releasing substances or neurohumoral factors which contribute to the acute opening of the BBB.

  8. FDM Analysis for Blood Flow through Stenosed Tapered Arteries

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2010-01-01

    Full Text Available Abstract A computational model is developed to analyze the unsteady flow of blood through stenosed tapered narrow arteries, treating blood as a two-fluid model with the suspension of all the erythrocytes in the core region as Herschel-Bulkley fluid and the plasma in the peripheral layer as Newtonian fluid. The finite difference method is employed to solve the resulting system of nonlinear partial differential equations. The effects of stenosis height, peripheral layer thickness, yield stress, viscosity ratio, angle of tapering and power law index on the velocity, wall shear stress, flow rate and the longitudinal impedance are analyzed. It is found that the velocity and flow rate increase with the increase of the peripheral layer thickness and decrease with the increase of the angle of tapering and depth of the stenosis. It is observed that the flow rate decreases nonlinearly with the increase of the viscosity ratio and yield stress. The estimates of the increase in the longitudinal impedance to flow are considerably lower for the two-fluid Herschel-Bulkley model compared with those of the single-fluid Herschel-Bulkley model. Hence, it is concluded that the presence of the peripheral layer helps in the functioning of the diseased arterial system.

  9. Relationship of daily arterial blood pressure monitoring readings and arterial stiffness profile in male patients with chronic obstructive pulmonary disease combined with arterial hypertension

    Directory of Open Access Journals (Sweden)

    Karoli N.A.

    2013-06-01

    Full Text Available The aim of the study was to determine correlation between arterial blood pressure daily rhythm and daily profile of arterial stiffness in male patients with chronic obstructive pulmonary disease (COPD and arterial hypertension. Materials et methods: Prospective investigation comprised 45 male patients with COPD and arterial hypertension. Individuals of 40 years younger and 80 years elder, patients with diabetes, stroke, angina pectoris, or heart infarction, vascular diseases, and exacerbation of chronic disease, bronchial and pulmonary diseases of other etiology were excluded from the analyses. Comparison group included 47 patients with essential arterial hypertension and without chronic respiratory diseases closely similar on general parameters with patients from main clinical series. Twenty-four-hour arterial blood pressure monitoring (ABPM and daily arterial stiffness monitoring were performed using BPLab® MnSDP-2 apparatus (Petr Telegin, Russian Federation. Results: Patients with COPD combined with arterial hypertension with raised arterial stiffness measures prevail over individuals in essential hypertension group. There is pathological alteration of the ABPM circadian rhythm and raised «Pressure load» values in raised arterial stiffness group. Conclusion: We found ABPM raised parameters in patients with COPD and arterial hypertension. It confirms necessity of ABPM in daily arterial stiffness assessment in patients with COPD.

  10. Choice of marker for assessment of RV dysfunction in acute pulmonary embolism : NT-proBNP, pulmonary artery systolic pressure, mean arterial pressure, or blood pressure index.

    Science.gov (United States)

    Ates, H; Ates, I; Kundi, H; Yilmaz, F M

    2017-12-01

    We aimed to examine the value of NT-proBNP, pulmonary artery systolic pressure (PASP), blood pressure index (BPI), and mean arterial pressure (MAP) in the determination of right ventricular dysfunction (RVD) in patients with acute pulmonary embolism (APE). A total of 547 patients diagnosed with APE were included in the study. Demographic characteristics and comorbid conditions of patients were recorded in patient files. For blood pressure measurement, a calibrated digital blood pressure monitor was used at regular intervals. Blood samples were taken from patients at the time of admission for hemogram, biochemical, and hemostasis blood tests. Echocardiography was performed on all patients to detect RVD and evaluate pulmonary artery pressure. PASP (p blood pressure (p blood cell (p AUC ± SE = 0.975 ± 0.006; p < 0.001) was found to be the best predictor of RVD with a higher sensitivity (92.8%) and specificity (100%). We found that BPI had a better diagnostic discrimination for RVD compared with PASP and NT-proBNP.

  11. Correlation between arterial and venous blood gas analysis parameters in patients with acute exacerbation of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Novović Miloš

    2012-01-01

    Full Text Available Introduction. Arterial blood gas (ABG analyses have an important role in the assessment and monitoring of the metabolic and oxygen status of patients with acute exacerbation of chronic obstructive pulmonary disease (COPD. Arterial puncture could have a lot of adverse effects, while sampling of venous blood is simpler and is not so invasive. Objective. The aim of this study was to evaluate whether venous blood gas (VBG values of pH, partial pressure of carbon dioxide (PCO2, partial oxygen pressure (PO2, bicarbonate (HCO3, and venous and arterial blood oxygen saturation (SO2 can reliably predict ABG levels in patients with acute exacerbation of COPD. Methods. Forty-seven patients with a prior diagnosis of COPD were included in this prospective study. The patients with acute exacerbation of this disease were examined at the General Hospital EMS Department in Prijepolje. ABG samples were taken immediately after venous sampling, and both were analyzed. Results. The Pearson correlation coefficients between arterial and venous parameters were 0.828, 0.877, 0.599, 0.896 and 0.312 for pH, PCO2, PO2, HCO3 and SO2, respectively. The statistically significant correlation between arterial and venous pH, PCO2 and HCO3, values was found in patients with acute exacerbation of COPD (p<0.001. Conclusion. When we cannot provide arterial blood for analysis, venous values of the pH, Pv,CO2 and HCO3 parameters can be an alternative to their arterial equivalents in the interpretation of the metabolic status in patients with acute exacerbation of COPD, while the values of venous Pv,O2 and Sv,O2 cannot be used as predictors in the assessment of oxygen status of such patients.

  12. MR measurement of coronary arterial blood flow velocity. Evaluation of age, stenosis and drugs as factors affecting coronary blood flow

    International Nuclear Information System (INIS)

    Taoka, Yoshiaki; Harada, Masafumi; Nishitani, Hiromu; Yukinaka, Michiko; Nomura, Masahiro

    1998-01-01

    Coronary arterial blood flow velocity was measured using MRI. Two types of phase contrast methods were used for the measurements, one of which exhibited good resolving power whereas the other provided more distinct images acquired while the subject patients held their breath. Before measuring coronary arterial blood flow velocity, accuracy of the two phase contrast methods was evaluated using a phantom. The results obtained with both methods largely agreed with the values obtained using the phantom. Using both methods, the patterns of coronary arterial blood flow over one cardiac cycle were essentially identical. A peak was noted in late systole or in early diastole in the right coronary artery, whereas in the left coronary artery, a peak was noted somewhat later in diastole. In healthy volunteers, no significant difference in the maximal flow velocity in the coronary arteries was found from one age group to another. Among patients with coronary arterial stenosis, coronary arterial blood flow velocity central to the area of stenosis was lower than that observed in the healthy volunteers. Coronary arterial blood flow velocity was observed to decrease after administration of isosorbide dinitrate and increased following administration of nifedipine. (author)

  13. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery

    International Nuclear Information System (INIS)

    Chin, K Y; Panerai, R B

    2013-01-01

    Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measurements closer to the ascending aorta, a new device was constructed to measure ABP in the superficial temporal artery (STA) using photoplethysmography and the arterial volume clamping technique. The optoelectronic circuitry to generate the photoplethysmogram is contained in a specially designed probe placed over the STA and kept in place with a head frame. The prototype (STAbp) also includes original designs for the pneumatic, electronic, signal processing, control and display sub-systems. A self-calibration feature regularly updates the photoplethysmogram operating point to improve accuracy. The performance of the STAbp was compared against the Finapres in 19 healthy subjects. At rest, the bias (SD d ) was −23.1 (15.05), −10.8 (13.83) and −12.4 (12.93) mmHg for systolic, mean and diastolic pressures respectively, without significant differences in drift between the two devices. The 99% bandwidth (SD) for the spectral distribution of ABP waveforms was 5.3 (1.46) Hz for STAbp and 6.8 (0.73) Hz for the Finapres (p < 0.01). Handgrip manoeuvre showed a very similar response to the Finapres, including the rapid return to baseline on release. The new STAbp device has considerable potential as a new tool for clinical and research applications where continuous recording of more central ABP is advantageous compared to peripheral alternatives. (paper)

  14. Arterial stiffness, cardiovagal baroreflex sensitivity and postural blood pressure changes in older adults: the Rotterdam Study

    NARCIS (Netherlands)

    Mattace-Raso, Francesco U. S.; van den Meiracker, Anton H.; Bos, Willem Jan; van der Cammen, Tischa J. M.; Westerhof, Berend E.; Elias-Smale, Suzette; Reneman, Robert S.; Hoeks, Arnold P. G.; Hofman, Albert; Witteman, Jacqueline C. M.

    2007-01-01

    Arterial stiffness may be involved in the impairment of the arterial baroreflex. In the present study the associations between arterial stiffness and cardiovagal baroreflex sensitivity (BRS) and between BRS and postural blood pressure (BP) changes were investigated within the framework of the

  15. Tracer measured substrate turnover requires arterial sampling downstream of infusion site

    International Nuclear Information System (INIS)

    Stanley, W.C.; Neese, R.A.; Gertz, E.W.; Wisneski, J.A.; Morris, D.L.; Brooks, G.A.

    1986-01-01

    Measurement of metabolite turnover (Rt) with radioactive tracers is done by either infusing tracer venously and sampling specific activity (SA) arterially (V-A modes), or by infusing into the aorta and sampling venous blood (A-V mode). Using the Fick principle, the necessity for using the V-A mode can be demonstrated. If tracer is infused into the left ventricle, in a steady state the Rt is the product of arterial trace concentration, the cardiac output, and the tracer extraction ratio for the whole body. This is expressed as: Rt = Ca x Qx ((*Ca - *Cv)/*Ca) (Eq1) where C=trace concentration (μmol/ml), *C=tracer conc. (dpm/ml), a=arterial, v-=mixed venous, and Q=cardiac output (ml/min). Rearranging the equation: Rt = Qx(*Ca - *Cv)/SAa = F/SAa (Eq2) where SAa is *Ca/Ca, and Qx (*Ca-*Cv) equals the infusion rate (F). The authors compared Eqs1 and 2 (Rt = F/SAa) in 3 anesthetized dogs in which [1- 14 C] lactate was infused into the left ventricle, and blood was sampled arterially downstream from the infusion site and in the pulmonary artery. Eqs 1 and 2 gave similar results for Rt (45.9 vs. 43.9 μmol/kg min), while substituting SAv for SAa (A-V mode) into Eq 2 gave a higher Rt (53.6). When SAv (A-V mode) is used, the specific activity seen by the tissues (SAa) is not considered in the calculation of Rt. Therefore, only the V-A mode meets the requirements for tracer measured metabolite turnover

  16. The artery blood supply variant of the upper limb

    Science.gov (United States)

    MASLARSKI, IVAN

    2015-01-01

    Variations of arterial patterns in the upper limb have represented the most common subject of vascular anatomy. Different types of artery branching pattern of the upper limb are very important for orthopedists in angiographic and microvascular surgical practice. The brachial artery (BA) is the most important vessel in the normal vascular anatomy of the upper limb. The classical pattern of the palmar hand region distribution shows the superficial palmar arch. Normally this arch is formed by the superficial branch of the ulnar artery and completed on the lateral side by one of these arteries: the superficial palmar branch of the radial artery, the princeps pollicis artery, the superficial palmar branch of the radial artery or the median artery. After the routine dissection of the right upper limb of an adult male cadaver, we found a very rare variant of the superficial arch artery – a division in a higher level brachial artery. We found this division at 10.4 cm from the beginning of the brachial artery. This superficial brachial artery became a radial artery and was not involved in the formation of the palm arch. In the forearm region, the artery variant was present with the median artery and the ulnar artery, which form the superficial palm arch. PMID:26733754

  17. Evaluation and investigation of regional cerebral blood flow by 1 point arterial blood collection method using 99mTc-ECD. Intravenous injection for 4 minutes with constant speed

    International Nuclear Information System (INIS)

    Itoh, Takeo; Shibata, Kazuhiro; Sudoh, Hideaki; Tanaka, Masato; Itoh, Kenjiro; Ueno, Yasushi

    1998-01-01

    Regional cerebral blood flow (rCBF) was measured using a 99m Tc-ECD through the 4-min constant intravenous infusion/one point arterial blood sampling method, proposed by Nakagawara et al. of Nakamura Memorial Hospital, and 133Xenon ( 133 Xe)-SPECT was performed on the same subjects to investigate the reproducibility of this method. We also determined whether cerebral blood flow (CBF) could be measured on the day of blood sampling through dilution of the obtained blood because it was difficult to measure the radioactivity in the blood on the day of blood sampling by this method. More, we investigated fixation of an octanol extraction rate and the substitution of venous blood for arterial blood in this method. The results revealed that CBF measured by this method with a 99m Tc-ECD were closely correlated to those measured by 133 Xe-SPECT, indicating the reliability as a method of measuring CBF. rCBF could be measured on the day of blood sampling through appropriate dilution of the obtained arterial blood. Octanol extraction rates were almost constant, indicating possible omission of cumbersome extraction procedure by fixation. However, the substitution of venous blood for arterial blood showed no correlation under the study system examined. (author)

  18. Blood vessel classification into arteries and veins in retinal images

    Science.gov (United States)

    Kondermann, Claudia; Kondermann, Daniel; Yan, Michelle

    2007-03-01

    The prevalence of diabetes is expected to increase dramatically in coming years; already today it accounts for a major proportion of the health care budget in many countries. Diabetic Retinopathy (DR), a micro vascular complication very often seen in diabetes patients, is the most common cause of visual loss in working age population of developed countries today. Since the possibility of slowing or even stopping the progress of this disease depends on the early detection of DR, an automatic analysis of fundus images would be of great help to the ophthalmologist due to the small size of the symptoms and the large number of patients. An important symptom for DR are abnormally wide veins leading to an unusually low ratio of the average diameter of arteries to veins (AVR). There are also other diseases like high blood pressure or diseases of the pancreas with one symptom being an abnormal AVR value. To determine it, a classification of vessels as arteries or veins is indispensable. As to our knowledge despite the importance there have only been two approaches to vessel classification yet. Therefore we propose an improved method. We compare two feature extraction methods and two classification methods based on support vector machines and neural networks. Given a hand-segmentation of vessels our approach achieves 95.32% correctly classified vessel pixels. This value decreases by 10% on average, if the result of a segmentation algorithm is used as basis for the classification.

  19. Functional assessment of the hepatic arterial blood flow by pharmacoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Stellamor, K; Hruby, W; Peschl, L

    1981-12-01

    By means of celiacography it was possible to demonstrate that parenteral medication with parathormone creates a selective dilatation of the liver vessels in man, provided that they are dilatable. This hemodynamic hormone effect could not be traced in the other mesenteric vessels. The increase of portal hypertension resulting from cirrhosis leads to a loss of the dilating ability of liver vessels. This regressive reaction is well demonstrated on the parathormone-celiacogram. Thus a functional assessment of the hepatic blood flow is possible. The extent of the dilatability of the liver artery seems to be of great importance for the prognosis and indication of the porto-systemic shunt-operation. Moreover we could show that an increase in the liver perfusion demonstrates pathologic liver processes in a better way.

  20. Continuous monitoring of arterial blood gases and pH during intraoperative rapid blood administration using a Paratrend sensor.

    Science.gov (United States)

    Vretzakis, G; Papaziogas, B; Matsaridou, E; Vasiliadou, G; Papadopoulos, G; Patsialas, C; Kostopoulou, F

    2000-01-01

    The aim of this study was to determine the effects of rapid transfusion of packed red cells on the arterial blood gases and acid-base status of the recipient. We studied 16 patients (mean age 66.3+/-9.9 years) who received rapid transfusion of 632.8+/-287.2 g of packed red cells in CPDA-1, stored before use for a period of 15.2+/-4.4 days. During transfusion, monitoring of pH, PCO2 and PO2 was continuous using an intra-arterial multiparameter sensor (Paratrend 7, Biomedical Sensors, UK). The rate of the transfusion was 73.1+/-9.6 g/min and the duration of observation was 35.8+/-12.8 min. Arterial pH decreased from 7.446+/-0.023 to 7.385+/-0.034 (pDelta pH and delta PCO2 showed significant correlation to the weight and the age of the transfused blood (pPO2 were not specific and our clinical impression was that they were related to unmeasured parameters. Our findings suggest that the fall in pH and the elevation in PCO2 which occur during rapid transfusion of packed red cells may go undetected or be misinterpreted if the acid-base status of the recipient is not monitored continuously. These alterations are mainly of metabolic character and depend on the amount and age of the transfused component. Our data suggest that arterial sampling is essential during massive transfusions.

  1. Comparison of two-dimensional MR angiography and microsphere measurement of renal blood flow for detection of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.A.; Lorenz, C.H.; Shetty, A.N.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper compares depiction of the renal arteries by MR angiography to renal blood flow as determined with microspheres in a dog model of renal artery stenosis. A left renal artery stenosis was created by placement of a silk ligature. Nb-95-labeled microspheres were injected into the left ventricle and a reference blood sample was drawn. The dog was imaged in the 1.5-T MR imager with two-dimensional MR angiography sequences. The kidneys were excised, weighted, divided into sections, and counted. Two dogs were studied to date. In dog 1, left renal blood flow (RBF) was 42 mL/min/100 g and right RBF was 337 mL/min/100 g. In dog 2 left RBF was 44 mL/min/100 g and right RBF was 608 mL/min/100 g

  2. Prediction of blood pressure and blood flow in stenosed renal arteries using CFD

    Science.gov (United States)

    Jhunjhunwala, Pooja; Padole, P. M.; Thombre, S. B.; Sane, Atul

    2018-04-01

    In the present work an attempt is made to develop a diagnostive tool for renal artery stenosis (RAS) which is inexpensive and in-vitro. To analyse the effects of increase in the degree of severity of stenosis on hypertension and blood flow, haemodynamic parameters are studied by performing numerical simulations. A total of 16 stenosed models with varying degree of stenosis severity from 0-97.11% are assessed numerically. Blood is modelled as a shear-thinning, non-Newtonian fluid using the Carreau model. Computational Fluid Dynamics (CFD) analysis is carried out to compute the values of flow parameters like maximum velocity and maximum pressure attained by blood due to stenosis under pulsatile flow. These values are further used to compute the increase in blood pressure and decrease in available blood flow to kidney. The computed available blood flow and secondary hypertension for varying extent of stenosis are mapped by curve fitting technique using MATLAB and a mathematical model is developed. Based on these mathematical models, a quantification tool is developed for tentative prediction of probable availability of blood flow to the kidney and severity of stenosis if secondary hypertension is known.

  3. Determining the Arterial Blood Pressure of People Living in Yesilyurt Local Healthcare Office

    Directory of Open Access Journals (Sweden)

    Feyza Dereli

    2009-02-01

    Full Text Available AIM: Whereas the prevalance of arterial blood pressure which was a chronical health problem was 20%-25% among 30 year-old people, them showing an increase in aging, the percentage went as high as 50% in 60’s and later ages. What was that worrisome was that despite the high prevalance, only half of these received treathment. This is study was descriptively and cross-sectionally planned to determine whether the people asking their tensions to be measured in and around the Yesilyurt local healthcare office region. METHODS: The environment of the research consisted of 1400 people over 35 age and registered Yesilyurt Local healthcare Office and the whole of the environment were included in this sample. The study was conducted over 340 voluntaries. The data was collected by a questionnaire of 14 questions containing socio-demografic features and by measuring the arterial blood pressure, height and weight of the individuals. In the evaluation of the data, chi-square test was used and the level of significantly was accepted as 0.05. RESULTS: In this study, the rate of high sistolic blood pressure was found to be 21.47% and the rate of high diastolic blood pressure to be 8.23%. It was determined that age and body mass index varrieties were effective on sistolic hipertension. It was also found that in their behaviors of the use of hypertensive medicine, of regular arterial pressure controls and of having the hypertesion diagnosis significant differnces varied statistically on both sistolic and diastolic blood pressure people having. CONCLUSION: In order to improve the health, informative information abouth hypertension was provided for the participants for too days consisting of 4 sessions. [TAF Prev Med Bull 2009; 8(1.000: 53-58

  4. Blood-conservation techniques for coronary-artery bypass surgery at a private hospital.

    Science.gov (United States)

    Davies, M J; Picken, J; Buxton, B F; Fuller, J A

    1988-11-21

    The utilization of homologous blood and blood products was recorded in 100 consecutive patients who underwent primary coronary-artery bypass surgery. Nine patients underwent saphenous-vein grafts only, 55 patients underwent a single internal-mammary-artery graft that was supplemented by vein grafts and 36 patients underwent bilateral internal-mammary-artery grafts and vein grafts. All patients underwent normovolaemic haemodilution, and autologous blood was collected before bypass surgery. Residual blood was collected from the cardiopulmonary bypass machine and was washed and concentrated in a cell processor, and blood also was scavenged postoperatively from the mediastinal drainage tubes as methods to conserve blood. The mean (+/- SD) utilization of homologous blood was 1.3 +/- 1.5 units with 0.2 +/- 0.7 units of fresh-frozen plasma being used, and 0.8 +/- 2.1 units of platelets being used. The utilization of homologous blood was not different among the three different methods of coronary-artery bypass surgery, but patients who underwent bilateral internal-mammary-artery grafts suffered a greater postoperative loss of blood than did those patients who underwent saphenous-vein grafts or single internal-mammary-artery grafts. A comparison of patients who were taking aspirin or a non-steroidal anti-inflammatory drug preoperatively with those patients who were not showed no difference in the utilization of homologous blood but a statistically-significant difference was found in the loss of blood postoperatively.

  5. Blood donors and factors impacting the blood donation decision: motives for donating blood in Turkish sample.

    Science.gov (United States)

    Karacan, Eda; Cengiz Seval, Guldane; Aktan, Zeynep; Ayli, Meltem; Palabiyikoglu, Refia

    2013-12-01

    Donations in Turkey are insufficient to cover the high transfusion needs arising from large numbers of thalassemia and sickle cell anemia patients and increasing demands for blood due to advanced surgery and cancer treatment. The most acceptable means to get blood is voluntary blood donation and the blood donor system in Turkey mostly depends on a combination of voluntary and involuntary donors. The main aim of this study is to explore the motivations of Turkish voluntary blood donors toward blood donation and to determine predictors of blood donation motivation. A cross-sectional sample survey of active blood donors in Ankara, Turkey was conducted. The sample consisted of 189 male volunteer blood donor adults. Donors filled in a self-administered questionnaire including the measures of demographic information, empathetic concern, altruism, social responsibility and blood donation motivation questionnaire during donation. Factor analysis of Blood Donation Motivation Measure with varimax rotation revealed a three-factor solution named as "values and moral duty", "positive feelings and esteem" and "self-benefit and external reasons". The results with regression analyses showed that only social responsibility had an significant effect independent of age, income, and education on blood donation motivation. These result reflects that blood donation motivation not only linked to a high degree of altruistic reasons, but also to a combination of some self-regarding motives. Additionally, feelings of empathy or altruism may be less strong at the time the decision to help, other factors may have a larger influence on helping decisions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. [Influence of Sympathetic Denervation of the Renal Artery on the Level of Arterial Blood Pressure, Cerebral Blood Flow and Cognitive Function In Patients With Resistant Arterial Hypertension].

    Science.gov (United States)

    Efimova, Y N; Lichikaki, A V; Lishmanov, B Y

    2017-07-01

    To study the effect of radiofrequency ablation of renal arteries on regional cerebral blood flow and cognitive function in patients with resistant arterial hypertension (AH). Transcatheter renal denervation (TRD) was performed in 17 patients with resistant AH. Examination before and after TRD included SPECT with mTc-HMPAO, 24-hours blood pressure (BP) monitoring, and comprehensive neuropsychological testing. Fifteen patients without angiographic signs of carotid atherosclerosis, coronary artery disease and AH, neurological and psychiatric disorders were investigated as control group. Compared with control group patients with AH had decreases of regional cerebral blood flow (rCBF) in right (by 13.5%, p=0.00002) and left (by 15.5%, p=0.0006) inferior frontal lobes, in right temporal brain region (by 11.5%, p=0.008); in right and left occipital lobes (by 8.2%, p=0.04). In 6 months after TRD we observed significant improvement of cognitive function, parameters of 24-hour BP monitoring, and rCBF. We also noted definite close interdependence between changes of rCBF, indices of 24-hours BP monitoring, and dynamics of cognitive function. Improvement of long-term verbal memory correlated with increases of rCBF in left superior frontal and right occipital regions while dynamics of mentation and attention correlated positively with augmentation of rCBF in right posterior parietal region. Changes of perfusion in inferior parts of left frontal lobe and in right occipital region correlated with dynamics of index of diurnal diastolic hypertension time (R2=0.64, p=0.001, and R2=0.60, p=0.03, respectively). Our results suggest, that in patients with resistant AH positive effect of TRD on levels of 24-hour mean BP as well as on indices of BP load leads to in augmentation of rCBF and improvement of cognitive function.

  7. Middle cerebral artery blood velocity and cerebral blood flow and O2 uptake during dynamic exercise

    DEFF Research Database (Denmark)

    Madsen, P L; Sperling, B K; Warming, T

    1993-01-01

    Results obtained by the 133Xe clearance method with external detectors and by transcranial Doppler sonography (TCD) suggest that dynamic exercise causes an increase of global average cerebral blood flow (CBF). These data are contradicted by earlier data obtained during less-well-defined conditions....... To investigate this controversy, we applied the Kety-Schmidt technique to measure the global average levels of CBF and cerebral metabolic rate of oxygen (CMRO2) during rest and dynamic exercise. Simultaneously with the determination of CBF and CMRO2, we used TCD to determine mean maximal flow velocity...... in the middle cerebral artery (MCA Vmean). For values of CBF and MCA Vmean a correction for an observed small drop in arterial PCO2 was carried out. Baseline values for global CBF and CMRO2 were 50.7 and 3.63 ml.100 g-1.min-1, respectively. The same values were found during dynamic exercise, whereas a 22% (P

  8. Relationship between retinal blood flow and arterial oxygen.

    Science.gov (United States)

    Cheng, Richard W; Yusof, Firdaus; Tsui, Edmund; Jong, Monica; Duffin, James; Flanagan, John G; Fisher, Joseph A; Hudson, Chris

    2016-02-01

    Vascular reactivity, the response of the vessels to a vasoactive stimulus such as hypoxia and hyperoxia, can be used to assess the vascular range of adjustment in which the vessels are able to compensate for changes in PO2. Previous studies in the retina have not accurately quantified retinal vascular responses and precisely targeted multiple PaO2 stimuli at the same time as controlling the level of carbon dioxide, thus precluding them from modelling the relationship between retinal blood flow and oxygen. The present study modelled the relationship between retinal blood flow and PaO2, showing them to be a combined linear and hyperbolic function. This model demonstrates that the resting tonus of the vessels is at the mid-point and that they have great vascular range of adjustment, compensating for decreases in oxygen above a PETCO2 of 32-37 mmHg but being limited below this threshold. Retinal blood flow (RBF) increases in response to a reduction in oxygen (hypoxia) but decreases in response to increased oxygen (hyperoxia). However, the relationship between blood flow and the arterial partial pressure of oxygen has not been quantified and modelled in the retina, particularly in the vascular reserve and resting tonus of the vessels. The present study aimed to determine the limitations of the retinal vasculature by modelling the relationship between RBF and oxygen. Retinal vascular responses were measured in 13 subjects for eight different blood gas conditions, with the end-tidal partial pressure of oxygen (PETCO2) ranging from 40-500 mmHg. Retinal vascular response measurements were repeated twice; using the Canon laser blood flowmeter (Canon Inc., Tokyo, Japan) during the first visit and using Doppler spectral domain optical coherence tomography during the second visit. We determined that the relationship between RBF and PaO2 can be modelled as a combination of hyperbolic and linear functions. We concluded that RBF compensated for decreases in arterial oxygen content

  9. Functional dilatation and medial remodeling of the renal artery in response to chronic increased blood flow.

    Science.gov (United States)

    Roan, Jun-Neng; Yeh, Chin-Yi; Chiu, Wen-Cheng; Lee, Chou-Hwei; Chang, Shih-Wei; Jiangshieh, Ya-Fen; Tsai, Yu-Chuan; Lam, Chen-Fuh

    2011-01-01

    Renal blood flow (RBF) is tightly regulated by several intrinsic pathways in maintaining optimal kidney blood supply. Using a rat model of aortocaval (AC) fistula, we investigated remodeling of the renal artery following prolonged increased blood flow. An AC fistula was created in the infrarenal aorta of anesthetized rats, and changes of blood flow in the renal artery were assessed using an ultrasonic flow probe. Morphological changes and expression of endothelial nitric oxide synthase and matrix metalloproteinase-2 in the remodeled renal artery were analyzed. Blood flow in the renal artery increased immediately after creation of AC fistula, but normal RBF was restored 8 weeks later. The renal artery dilated significantly 8 weeks after operation. Expression of endothelial nitric oxide synthase and matrix metalloproteinase-2 was upregulated shortly after blood flow increase, and returned to baseline levels after 3 weeks. Histological sections showed luminal dilatation with medial thickening and endothelial cell-to-smooth muscle cell attachments in the remodeled renal artery. Increased RBF was accommodated by functional dilatation and remodeling in the medial layer of the renal artery in order to restore normal blood flow. Our results provide important mechanistic insight into the intrinsic regulation of the renal artery in response to increased RBF. Copyright © 2011 S. Karger AG, Basel.

  10. Analysis of Arterial and Venous Blood Gases in Healthy Gyr Falcons ( Falco rusticolus ) Under Anesthesia.

    Science.gov (United States)

    Raghav, Raj; Middleton, Rachael; BSc, Rinshiya Ahamed; Arjunan, Raji; Caliendo, Valentina

    2015-12-01

    Arterial and venous blood gas analysis is useful in the assessment of tissue oxygenation and ventilation and in diagnosis of metabolic and respiratory derangements. It can be performed with a relatively small volume of blood in avian patients under emergency situations. Arterial and venous blood gas analysis was performed in 30 healthy gyr falcons ( Falco rusticolus ) under anaesthesia to establish temperature-corrected reference intervals for arterial blood gas values and to compare them to temperature-corrected venous blood gas values with a portable point-of-care blood gas analyzer (i-STAT 1, Abbott Laboratories, Abbott Park, IL, USA). Statistically significant differences were observed between the temperature-corrected values of pH, partial pressure of carbon dioxide (Pco2), and partial pressure of oxygen (Po2) and the corresponding nontemperature-corrected values of these parameters in both arterial and venous blood. Values of temperature-corrected pH, temperature-corrected Pco2, bicarbonate concentrations, and base excess of extra cellular fluid did not differ significantly between arterial and venous blood, suggesting that, in anesthetized gyr falcons, venous blood gas analysis can be used in place of arterial blood gas analysis in clinical situations. Values for hematocrit, measured by the point-of-care analyzer, were significantly lower compared with those obtained by the microhematocrit method.

  11. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  12. Straight versus tortuous retinal arteries in relation to blood pressure and genetics

    DEFF Research Database (Denmark)

    Taarnhøj, N C B B; Munch, I C; Sander, B

    2008-01-01

    dizygotic same-sex healthy twin pairs, aged 20 to 46 years, who were characterised by determination of retinal vessel diameters, arterial blood pressure, blood glucose, body mass index, smoking habits and retinal arterial tortuosity, using a three-level grading scale (straight, wavy, tortuous). Heritability......BACKGROUND/AIMS: To assess the relative influence of genetic and environmental factors on retinal arterial tortuosity and the association between tortuosity and various health indices in healthy young to middle-aged persons. METHODS: This cross-sectional study included 57 monozygotic and 52...... accounting for the remaining 18% (CI(95 )8, 36%). Increasing values of mean arterial blood pressure and body mass index were both associated with decreasing levels of retinal arterial tortuosity. CONCLUSION: There was a large variation in tortuosity of retinal arteries in these healthy subjects...

  13. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  14. Congener Production in Blood Samples During Preparation and Storage

    DEFF Research Database (Denmark)

    Felby, Søren; Nielsen, Erik

    1995-01-01

    Retsmedicin, congener production, preparation, head space GC, acetone, isobutanol, storage, blood samples, n-propanol, methanol, methylethylketone......Retsmedicin, congener production, preparation, head space GC, acetone, isobutanol, storage, blood samples, n-propanol, methanol, methylethylketone...

  15. Blood pressure and arterial stiffness in obese children and adolescents.

    Science.gov (United States)

    Hvidt, Kristian Nebelin

    2015-03-01

    Obesity, elevated blood pressure (BP) and arterial stiffness are risk factors for cardiovascular disease. A strong relationship exists between obesity and elevated BP in both children and adults. Obesity and elevated BP in childhood track into adult life increasing the risk of cardiovascular disease in adulthood. Ambulatory BP is the most precise measure to evaluate the BP burden, whereas carotid-femoral pulse wave velocity (cfPWV) is regarded as the gold standard for evaluating arterial (i.e. aortic) stiffness. These measures might contribute to a better understanding of obesity's adverse impact on the cardiovascular system, and ultimately a better prevention and treatment of childhood obesity. The overall aim of the present PhD thesis is to investigate arterial stiffness and 24-hour BP in obese children and adolescents, and evaluate whether these measures are influenced by weight reduction. The present PhD thesis is based on four scientific papers.  In a cross-sectional design, 104 severe obese children and adolescents with an age of 10-18 years were recruited when newly referred to the Children's Obesity Clinic, Holbæk University Hospital, and compared to 50 normal weighted age and gender matched control individuals. Ambulatory BP was measured, and cfPWV was investigated in two ways in respect to the distance measure of aorta; the previously recommended length - the so called subtracted distance, and the currently recommended length - the direct distance. In a longitudinal design, the obese patients were re-investigated after one-year of lifestyle intervention at the Children's Obesity Clinic in purpose of reducing the degree of obesity. In the cross-sectional design, the obese group had higher measures of obesity, while matched for age, gender and height, when compared to the control group. In the longitudinal design, 74% of the 72 followed up obese patients experienced a significant weight reduction. CfPWV was dependent on the method used to measure the

  16. Biomarkers of coagulation, fibrinolysis, endothelial function, and inflammation in arterialized venous blood

    DEFF Research Database (Denmark)

    Gram, Anne Sofie; Skov, Jane; Ploug, Thorkil

    2014-01-01

    Effects of venous blood arterialization on cardiovascular risk markers are still unknown. We evaluated biomarkers of inflammation, coagulation, fibrinolysis, and endothelial function in arterialized compared with regular venous blood. Cubital venipunctures were obtained from 10 healthy volunteers....... Arterialization was generated by 10 min heating of the contralateral hand. Concentrations of albumin, C-reactive protein (CRP), tissue-type plasminogen activator (t-PA), plasminogen activator inhibitor type 1 (PAI-1), and von Willebrand factor (vWF) were measured by validated assays. Concentrations of albumin......, CRP, and vWF were significantly lower in arterialized than in venous blood (albumin: 43.8 g/l and 44.8 g/l, P = 0.02). Differences in CRP and vWF became insignificant after adjusting for albumin. The endogenous thrombin potential (ETP) was significantly higher in arterialized than in venous blood...

  17. Impact of blood sampling in very preterm infants

    DEFF Research Database (Denmark)

    Madsen, L P; Rasmussen, M K; Bjerregaard, L L

    2000-01-01

    ; the groups were then subdivided into critically ill or not. Diagnostic blood sampling and blood transfusion events were recorded. In total, 1905 blood samples (5,253 analysis) were performed, corresponding to 0.7 samples (1.9 analysis) per day per infant. The highest frequencies were found during the first....../kg. For the extremely preterm infants a significant correlation between sampled and transfused blood volume was found (mean 37.1 and 33.3 ml/kg, respectively, r = + 0.71, p = 0.0003). The most frequently requested analyses were glucose, sodium and potassium. Few blood gas analyses were requested (1.9/ infant). No blood...... losses attributable to excessive generous sampling were detected. The results show an acceptable low frequency of sampling and transfusion events for infants of GA 28-32 weeks. The study emphasizes the necessity of thorough reflection and monitoring of blood losses when ordering blood sampling...

  18. Respiratory properties of blood and arterial blood gases in the tegu lizard: effects of temperature and hypercapnia.

    Science.gov (United States)

    Wood, S C; Glass, M L; Andersen, N A; Heisler, N

    1987-01-01

    The effects of body temperature and hypercapnia (7% inspired CO2) on arterial blood gases, plasma pH, and the characteristics of the blood oxygen dissociation curve were determined in Tegu lizards (Tupinambis nigropunctatus). Arterial pH fell from 7.59 to 7.50 when body temperature was increased from 25 to 35 degrees C. The pH/temperature coefficient (delta pH/delta t = -0.009 U/degrees C) was half of that predicted on the basis of 'constant relative alkalinity' and the alphastat hypothesis. The fall in plasma pH resulted from a decrease in plasma [HCO3-], and a rise in plasma Pco2. The O2 affinity of Tegu blood, expressed by the partial pressure at half saturation (P50), decreased with temperature in vitro from 42.3 to 49.6 torr at pH 7.4. The apparent enthalpy (delta H = -3.1 kcal/mol) is about 1/4 of that of human blood. In vivo, the arterial blood oxygen saturation decreased from 89% at 25 degrees to 82% at 35 degrees C. Arterial Po2 increased from 61 to 71 torr as expected from the right-shift of the oxygen dissociation curve. During environmental hypercapnia (7% CO2, 21% O2, 72% N2 inspired concentrations), arterial pH decreased to 7.28. Arterial O2 saturation remained constant and arterial Po2 increased from 61 to 85 torr due to the right-shift of the oxygen dissociation curve. The comparatively small effect of changes in temperature on the oxygen affinity of Tegu blood (directly according to the delta H value, and indirectly via changes in blood pH) results in a relatively small right shift of the oxygen dissociation curve, and accordingly in relatively high arterial and tissue Po2 values also at higher temperatures.

  19. The effect of sensory stimulation provided by family on arterial blood oxygen saturation in critical care patients.

    Science.gov (United States)

    Yousefi, Hojatollah; Naderi, Mojgan; Daryabeigi, Reza

    2015-01-01

    Stressors in the intensive care unit (ICU) impair patients' comfort, excite the stress response, and increase oxygen consumption in their body. Non-medical interventions are recommended by several studies as a treatment to improve comfort in the ICU patients. Sensory stimulation is one of the most important interventions. Since arterial blood oxygen saturation is an important index of patients' clinical and respiratory condition, this study aimed to investigate the effect of sensory stimulation provided by family on arterial blood oxygen saturation in critical care patients. This study is a clinical trial conducted on 64 patients hospitalized in the ICU wards of Al-Zahra and Kashani hospitals in Isfahan, Iran in 2012 and 2013. The patients were selected by simple sampling method and were randomly assigned to two groups (study and control). Patients' arterial blood oxygen saturations were measured 10 min before, immediately after, 10 min and 30 min after sensory stimulation in the study group, and simultaneously in the control group without any intervention. Repeated measures analysis of variance (ANOVA) showed a significant difference in the mean of arterial blood oxygen saturation levels 10 min before, immediately after, 10 min and 30 min after sensory stimulation in the study group (P 0.18). Application of sensory stimulations as a nursing and non-medical intervention by the family members improves comfort and increases the level of blood oxygen saturation in critical care patients.

  20. The origin of extrarenal arterial blood supply of renal malignancy and its clinical value

    International Nuclear Information System (INIS)

    Du Duanming; Tong Xiaoqiang; Song Li; Zou Yinghua

    2007-01-01

    Objective: To study the mechanisms of extrarenal arterial blood supply of renal malignancy for its interventional therapy. Methods: Routine abdominal aortography and selective questionable feeding arteriography were performed in 141 patients with renal malignancy. The characteristics and formation mechanisms of extrarenal arterial blood supply for renal malignancy were analyzed. Results: Of the 141 patients, extrarenal arterial blood supply of renal malignancy were found in 51 patients and there were 87 branchs. The breakthrough of renal capsule with malignancy were found in those 51 patients. No extrarenal arterial blood supply of renal malignancy was found in 90 patients, including 50 patients with and 40 patients without the renal capsule breakthrough with malignancy. The emerge of extrarenal arterial blood supply of renal malignancy were significantly different (χ 2 =31.64, P<0.01) between the patients with and without the breakthrough of renal capsule with malignancy. The origin of extrarenal arterial blood supply were correlated with the location of the tumor. Conclusions: It is important to determine the origin of the extrarenal arterial blood supply in renal malignancy for its interventional therapy. (authors)

  1. Circadian rhythm of arterial blood pressure and albuminuria in diabetic nephropathy

    DEFF Research Database (Denmark)

    Hansen, H P; Rossing, P; Tarnow, L

    1996-01-01

    The aim of our study was to evaluate the diurnal relationship between arterial blood pressure and albuminuria, and some potential mechanisms responsible for impaired nocturnal blood pressure reduction (non-dippers, groups I and II) in diabetic nephropathy (DN). Twenty-four-hour ambulatory blood p...

  2. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  3. Clinical observations on the effect of carotid artery occlusion on cerebral blood flow mapped by xenon computed tomography and its correlation with carotid artery back pressure

    International Nuclear Information System (INIS)

    Steed, D.L.; Webster, M.W.; DeVries, E.J.; Jungreis, C.A.; Horton, J.A.; Sehkar, L.; Yonas, H.

    1990-01-01

    Xenon computed tomographic cerebral blood flow mapping was correlated with internal carotid artery stump pressures and clinical neurologic assessment during temporary internal carotid artery occlusion. One hundred fourteen patients with skull base tumors or intracranial aneurysms potentially requiring carotid resection or ligation underwent angiography, xenon CT cerebral blood flow mapping, and internal carotid artery blood pressure monitoring. The internal carotid artery was then temporarily occluded with a balloon catheter, stump pressure was measured through the catheter, and the xenon CT cerebral blood flow mapping was repeated. Adequate xenon CT cerebral blood flow was defined as greater than 30 cc/100 gm/min. All patients had normal xenon CT cerebral blood flow before internal carotid artery occlusion. During internal carotid artery occlusion, xenon CT cerebral blood flow was found to be normal (group I, 40 patients), globally reduced but still within the normal range (group II, 50 patients), or low in the distribution of the ipsilateral middle cerebral artery (group III, 13 patients). With balloon occlusion, an immediate neurologic deficit developed in 11 patients (9%) requiring deflation of the balloon preceding xenon CT cerebral blood flow measurement (group IV). In group I internal carotid artery blood pressure was 128 mm Hg. (range 85 to 171 mm Hg) with stump pressure 86 mm Hg (range 46 to 125 mm Hg). In group II internal carotid artery blood pressure was 130 mm Hg. (range 78 to 199 mm Hg), with stump pressure 86 mm Hg (range 31 to 150 mm Hg)

  4. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting.

    Science.gov (United States)

    Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi

    2016-01-01

    When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  5. Systemic arterial hypertension, blood pressure levels and associated factors in schoolchildren

    Directory of Open Access Journals (Sweden)

    Priscila Heleno

    Full Text Available Summary Introduction: Hypertension is a major public health problem in contemporary times and it has high prevalence throughout the world. Objective: To investigate the situation of Systemic Arterial Hypertension in schoolchildren aged 6 to 10 years in Divinópolis/MG-Brazil and associated factors. Method: This is a cross-sectional, epidemiological, descriptive and analytical study, whose population was children aged 6 to 10 years enrolled in public schools in Divinópolis-MG-Brazil. Data collection was conducted from October 2014 to May 2015. Multivariate linear regressions were used to test associations between blood pressure, socioeconomic, anthropometric, dietary and physical activity. Results: The prevalence of hypertension was 15.2% in a sample of 284 children and mean values of systolic blood pressure of 101.7 (±13.2 mmHg and diastolic blood pressure of 66.0 (±11.2 mmHg. The body fat percentage showed significant differences between the genders, with 24.2 and 26.2%, respectively for boys and girls. Significant associations were made between blood pressure levels, body weight, body mass index, waist circumference, body fat percentage, consumption of yogurt, beef /chicken, beans, pizza, sandwich and some behaviors variables. Conclusion: The presented data show important aspects of school profile in the age range 6-10 years, especially related to the behavior of blood pressure.

  6. Multidrug resistant Salmonellae isolated from blood culture samples ...

    African Journals Online (AJOL)

    This study investigates the prevalence of R-plasmids in Salmonella sp. isolated from blood samples of suspected typhoid patients in Warri, Nigeria. A total of 136 blood samples were collected between May and December,2009 and screened for the presence of Salmonellae using standard blood culture techniques of which ...

  7. Investigating complex patterns of blocked intestinal artery blood pressure signals by empirical mode decomposition and linguistic analysis

    International Nuclear Information System (INIS)

    Yeh, J-R; Lin, T-Y; Shieh, J-S; Chen, Y; Huang, N E; Wu, Z; Peng, C-K

    2008-01-01

    In this investigation, surgical operations of blocked intestinal artery have been conducted on pigs to simulate the condition of acute mesenteric arterial occlusion. The empirical mode decomposition method and the algorithm of linguistic analysis were applied to verify the blood pressure signals in simulated situation. We assumed that there was some information hidden in the high-frequency part of the blood pressure signal when an intestinal artery is blocked. The empirical mode decomposition method (EMD) has been applied to decompose the intrinsic mode functions (IMF) from a complex time series. But, the end effects and phenomenon of intermittence damage the consistence of each IMF. Thus, we proposed the complementary ensemble empirical mode decomposition method (CEEMD) to solve the problems of end effects and the phenomenon of intermittence. The main wave of blood pressure signals can be reconstructed by the main components, identified by Monte Carlo verification, and removed from the original signal to derive a riding wave. Furthermore, the concept of linguistic analysis was applied to design the blocking index to verify the pattern of riding wave of blood pressure using the measurements of dissimilarity. Blocking index works well to identify the situation in which the sampled time series of blood pressure signal was recorded. Here, these two totally different algorithms are successfully integrated and the existence of the existence of information hidden in high-frequency part of blood pressure signal has been proven

  8. Investigating complex patterns of blocked intestinal artery blood pressure signals by empirical mode decomposition and linguistic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, J-R; Lin, T-Y; Shieh, J-S [Department of Mechanical Engineering, Yuan Ze University, 135 Far-East Road, Chung-Li, Taoyuan, Taiwan (China); Chen, Y [Far Eastern Memorial Hospital, Taiwan (China); Huang, N E [Research Center for Adaptive Data Analysis, National Central University, Taiwan (China); Wu, Z [Center for Ocean-Land-Atmosphere Studies (United States); Peng, C-K [Beth Israel Deaconess Medical Center, Harvard Medical School (United States)], E-mail: s939205@ mail.yzu.edu.tw

    2008-02-15

    In this investigation, surgical operations of blocked intestinal artery have been conducted on pigs to simulate the condition of acute mesenteric arterial occlusion. The empirical mode decomposition method and the algorithm of linguistic analysis were applied to verify the blood pressure signals in simulated situation. We assumed that there was some information hidden in the high-frequency part of the blood pressure signal when an intestinal artery is blocked. The empirical mode decomposition method (EMD) has been applied to decompose the intrinsic mode functions (IMF) from a complex time series. But, the end effects and phenomenon of intermittence damage the consistence of each IMF. Thus, we proposed the complementary ensemble empirical mode decomposition method (CEEMD) to solve the problems of end effects and the phenomenon of intermittence. The main wave of blood pressure signals can be reconstructed by the main components, identified by Monte Carlo verification, and removed from the original signal to derive a riding wave. Furthermore, the concept of linguistic analysis was applied to design the blocking index to verify the pattern of riding wave of blood pressure using the measurements of dissimilarity. Blocking index works well to identify the situation in which the sampled time series of blood pressure signal was recorded. Here, these two totally different algorithms are successfully integrated and the existence of the existence of information hidden in high-frequency part of blood pressure signal has been proven.

  9. A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling

    International Nuclear Information System (INIS)

    Iida, Hidehiro; Itoh, Hiroshi; Bloomfield, P.M.; Munaka, Masahiro; Higano, Shuichi; Murakami, Matsutaro; Inugami, Atsushi; Eberl, S.; Aizawa, Yasuo; Kanno, Iwao; Uemura, Kazuo

    1994-01-01

    A method has been developed to quantitate regional cerebral blood blow (rCBF) using iodine-123-labelled N-isopropyl-p-iodoamphetamine (IMP). This technique requires only two single-photon emission tomography (SPET) scans and one blood sample. Based on a two-compartment model, radioactivity concentrations in the brain for each scan time are calculated. A standard input function has been generated by combining the input functions from 12 independent studies prior to this work to avoid frequent arterial blood sampling, and one blood sample is taken at 10 min following IMP administration for calibration of the standard arterial input function. This calibration time was determined such that the integration of the first 40 min of the calibrated, combined input function agreed best with those from 12 individual input functions (the difference was 5.3% on average). This method was applied to eight subjects (two normals and six patients with cerebral infarction), and yielded rCBF values which agreed well with those obtained by a positron emission tomography H 2 15 O autoradiography method. This method was also found to provide rCBF values that were consistent with those obtained by the non-linear least squares fitting technique and those obtained by conventional microsphere model analysis. The optimum SPET scan times were found to be 40 and 180 min for the early and delayed scans, respectively. These scan times allow the use of a conventional rotating gamma camera for clinical purposes. V d values ranged between 10 and 40 ml/g depending on the pathological condition, thereby suggesting the importance of measuring V d for each ROI. In conclusion, optimization of the blood sampling time and the scanning time enabled quantitative measurement of rCBF with two SPET scans and one blood sample. (orig.)

  10. [Baroreflexes originated in vertebral artery zones upon peripheral vein tonus, systemic arterial blood pressure, and external respiration].

    Science.gov (United States)

    Agadzhanian, N A; Kupriianov, S V

    2008-06-01

    The investigation was intended to study the role ofbaroreceptors ofhemodynamically isolated zone of vertebral arteries in regulation of peripheral veins tonus, arterial pressure and external respiration. Pressure decrease in this vascular reflexogenic zone led to reflex responses of increase in femoral vein tonus, elevation of blood pressure level and stimulation of external respiration. The opposite reflex responses of cardio-respiratory functional system to initial pressure activation of vertebral arteries baroreceptors are observed. Basing on generalization of our own findings and similar physiological and morphological researches of other authors, it is established that afferentation from the vertebral artery zone is a reflexogenic factor of somatic muscles' veins tonus regulation. These reflexes of capacity vessels tonic activity changes are part of cardio-respiratory responses of maintaining the tissue gaseous exchange.

  11. Classification of peripheral occlusive arterial diseases based on symptoms, signs and distal blood pressure measurements

    DEFF Research Database (Denmark)

    Tønnesen, K H; Noer, Ivan; Paaske, William

    1980-01-01

    Systolic blood pressures at toe and ankle were measured in 459 consecutive patients with occlusive arterial disease. Fifty-eight per cent had intermittent claudication with arterial disease of all degrees of severity. Seventeen per cent complained of rest pain having toe systolic pressures below 30...

  12. Measurement of blood flow in the carotid arteries using color doppler in healthy Korean adults

    International Nuclear Information System (INIS)

    Moon, Ki Ho; Jeon, Do Ig; Choi, Chang Ho; Ro, Young Jin; Kim, Hak Jin; Lee, Suck Hong; Kim, Byung Soo

    1994-01-01

    To evaluate the blood flow patterns and velocities of the carotid arteries in healthy Korean adults. We evaluated the blood flow patterns and measured the peak systolic and end-diastolic velocities of the common, internal and external carotid arteries in 48 healthy adults who did not have cardiovascular disorders and neck lesions. The velocity difference was analyzed according to different age groups. In addition, peak systolic and end-diastolic velocity ratio of the internal to common carotid artery was estimated, and our data were compared with values reported by other authors. Generally, the velocity in the younger age group tends be to higher than in older group. The peak systolic and end diastolic velocities of the internal carotid artery were 84.5 cm/sec and 30.5 cm/sec. The peak systolic and end diastolic velocity ratio of the internal to common carotid artery were 0.715 and 0.966. The internal carotid artery was less resistant in blood flow than the external carotid artery. Our data were lower than the values which were reported by Bluth et al. The blood flow velocities of the internal carotid artery in healthy adults were lower than those of previous reported foreign values, but the patterns were similar

  13. Intraoperative changes of transcranial Doppler velocity: relation to arterial oxygen content and whole-blood viscosity

    NARCIS (Netherlands)

    Schuurman, P. R.; Albrecht, K. W.

    1999-01-01

    The association of arterial oxygen content (CaO2) and viscosity with transcranial Doppler (TCD) blood flow velocity in the middle cerebral artery was studied in 20 adults without cerebrovascular disease undergoing abdominal surgery associated with significant fluctuations in hematology. TCD

  14. Autologous Transfusion of Stored Red Blood Cells Increases Pulmonary Artery Pressure

    Science.gov (United States)

    Pinciroli, Riccardo; Stowell, Christopher P.; Wang, Lin; Yu, Binglan; Fernandez, Bernadette O.; Feelisch, Martin; Mietto, Cristina; Hod, Eldad A.; Chipman, Daniel; Scherrer-Crosbie, Marielle; Bloch, Kenneth D.; Zapol, Warren M.

    2014-01-01

    Rationale: Transfusion of erythrocytes stored for prolonged periods is associated with increased mortality. Erythrocytes undergo hemolysis during storage and after transfusion. Plasma hemoglobin scavenges endogenous nitric oxide leading to systemic and pulmonary vasoconstriction. Objectives: We hypothesized that transfusion of autologous blood stored for 40 days would increase the pulmonary artery pressure in volunteers with endothelial dysfunction (impaired endothelial production of nitric oxide). We also tested whether breathing nitric oxide before and during transfusion could prevent the increase of pulmonary artery pressure. Methods: Fourteen obese adults with endothelial dysfunction were enrolled in a randomized crossover study of transfusing autologous, leukoreduced blood stored for either 3 or 40 days. Volunteers were transfused with 3-day blood, 40-day blood, and 40-day blood while breathing 80 ppm nitric oxide. Measurements and Main Results: The age of volunteers was 41 ± 4 years (mean ± SEM), and their body mass index was 33.4 ± 1.3 kg/m2. Plasma hemoglobin concentrations increased after transfusion with 40-day and 40-day plus nitric oxide blood but not after transfusing 3-day blood. Mean pulmonary artery pressure, estimated by transthoracic echocardiography, increased after transfusing 40-day blood (18 ± 2 to 23 ± 2 mm Hg; P transfusing 3-day blood (17 ± 2 to 18 ± 2 mm Hg; P = 0.5). Breathing nitric oxide decreased pulmonary artery pressure in volunteers transfused with 40-day blood (17 ± 2 to 12 ± 1 mm Hg; P Transfusion of autologous leukoreduced blood stored for 40 days was associated with increased plasma hemoglobin levels and increased pulmonary artery pressure. Breathing nitric oxide prevents the increase of pulmonary artery pressure produced by transfusing stored blood. Clinical trial registered with www.clinicaltrials.gov (NCT 01529502). PMID:25162920

  15. Combination syringe provides air-free blood samples

    Science.gov (United States)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  16. Respiratory sinus arrhythmia stabilizes mean arterial blood pressure at high-frequency interval in healthy humans.

    Science.gov (United States)

    Elstad, Maja; Walløe, Lars; Holme, Nathalie L A; Maes, Elke; Thoresen, Marianne

    2015-03-01

    Arterial blood pressure variations are an independent risk factor for end organ failure. Respiratory sinus arrhythmia (RSA) is a sign of a healthy cardiovascular system. However, whether RSA counteracts arterial blood pressure variations during the respiratory cycle remains controversial. We restricted normal RSA with non-invasive intermittent positive pressure ventilation (IPPV) to test the hypothesis that RSA normally functions to stabilize mean arterial blood pressure. Ten young volunteers were investigated during metronome-paced breathing and IPPV. Heart rate (ECG), mean arterial blood pressure and left stroke volume (finger arterial pressure curve) and right stroke volume (pulsed ultrasound Doppler) were recorded, while systemic and pulmonary blood flow were calculated beat-by-beat. Respiratory variations (high-frequency power, 0.15-0.40 Hz) in cardiovascular variables were estimated by spectral analysis. Phase angles and correlation were calculated by cross-spectral analysis. The magnitude of RSA was reduced from 4.9 bpm(2) (95% CI 3.0, 6.2) during metronome breathing to 2.8 bpm(2) (95% CI 1.1, 5.0) during IPPV (p = 0.03). Variations in mean arterial blood pressure were greater (2.3 mmHg(2) (95% CI 1.4, 3.9) during IPPV than during metronome breathing (1.0 mmHg(2) [95% CI 0.7, 1.3]) (p = 0.014). Respiratory variations in right and left stroke volumes were inversely related in the respiratory cycle during both metronome breathing and IPPV. RSA magnitude is lower and mean arterial blood pressure variability is greater during IPPV than during metronome breathing. We conclude that in healthy humans, RSA stabilizes mean arterial blood pressure at respiratory frequency.

  17. The influence of the non-Newtonian properties of blood on blood-hammer through the posterior cerebral artery.

    Science.gov (United States)

    Tazraei, Pedram; Riasi, Alireza; Takabi, Behrouz

    2015-06-01

    This work investigates a two dimensional numerical analysis of blood hammer through the posterior cerebral artery. The non-Newtonian and usual Newtonian blood models are compared in the case of blood hammer through the posterior cerebral artery to quantify the differences between the models. In this way, a validated CFD simulation is used to study non-Newtonian shear-thinning effects of blood. The governing equations for the modeling of two-dimensional transient flow are solved using a combination of characteristics and central finite difference methods, respectively for the hyperbolic and parabolic parts. Herein, the non-Newtonian viscosity characteristic of blood is incorporated by using the Carreau model. To convert the nonlinear terms available in the characteristics equation into the linear ones, the Newton-Kantorovich method is implemented. The verification and validation of the numerical results are carried out in detail. Hemodynamic characteristics of blood hammer through the posterior cerebral artery are derived with both the Newtonian and non-Newtonian models, and the results are meticulously compared and discussed. The results show that when blood hammer occurs, the non-Newtonian properties greatly influence the velocity and shear stress profiles. At the early stages of blood hammer, there is a 64% difference between magnitudes of wall shear stress in these two models, and the magnitude of the wall shear stress for the shear-thinning blood flow is lower than the Newtonian one. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. [Basic laws of blood screw motion in human common carotid arteries].

    Science.gov (United States)

    Kulikov, V P; Kirsanov, R I

    2008-08-01

    The basic laws of blood screw motion in common carotid arteries in people were determined by means of modern ultrasound techniques for the first time. 92 healthy adults, aged 18-30, were examined. The blood flow in the middle one-third of common carotid arteries was registered by means of Color Doppler Imaging and impulse Doppler with the help of ultrasound Medison 8000EX scanner by linear transducer of 5-9 MHz. The steady registration of blood screw motion in both common carotid arteries in Color Doppler Imaging regimen was observed in 54.3 % of cases. The direction of screw stream rotation in most cases (54%) was multi-directed: in the right common carotid artery it was right, in the left common carotid artery--left (48%), and in 6% of cases it was reverse. For 46% of cases blood rotation in both common carotid arteries was one-directed (26%--right, 20%--left). The velocity parameters of rotation component of blood motion were determined, maximum velocity being 19.68 +/- 5.84 cm/sec, minimum--4.57 +/- 2.89 cm/sec, average--7.48 +/- 2.49 cm/sec, angular--10.7 +/- 2.49 sec(-1). The rated velocity of blood cells motion in screw motion with regard of screw current lines to the vessel vertical axis makes up from 158.67 +/- 32.79 to 224.39 +/- 46.37 cm/sec.

  19. A common humoral background of intraocular and arterial blood pressure dysregulation.

    Science.gov (United States)

    Skrzypecki, Janusz; Grabska-Liberek, Iwona; Przybek, Joanna; Ufnal, Marcin

    2018-03-01

    It has been postulated that intraocular pressure, an important glaucoma risk factor, correlates positively with arterial blood pressure (blood pressure). However, results of experimental and clinical studies are often contradictory. It is hypothesized that, in some hypertensive patients, disturbances in intraocular pressure regulation may depend on biological effects of blood borne hormones underlying a particular type of hypertension, rather than on blood pressure level itself. This review compares the effects of hormones on blood pressure and intraocular pressure, in order to identify a hormonal profile of hypertensive patients with an increased risk of intraocular pressure surge. The PUBMED database was searched to identify pre-clinical and clinical studies investigating the role of angiotensin II, vasopressin, adrenaline, noradrenaline, prostaglandins, and gaseous transmitters in the regulation of blood pressure and intraocular pressure. Studies included in the review suggest that intraocular and blood pressures often follow a different pattern of response to the same hormone. For example, vasopressin increases blood pressure, but decreases intraocular pressure. In contrast, high level of nitric oxide decreases blood pressure, but increases intraocular pressure. Arterial hypertension is associated with altered levels of blood borne hormones. Contradicting results of studies on the relationship between arterial hypertension and intraocular pressure might be partially explained by diverse effects of hormones on arterial and intraocular pressures. Further studies are needed to evaluate if hormonal profiling may help to identify glaucoma-prone patients.

  20. CT perfusion of the liver during selective hepatic arteriography. Pure arterial blood perfusion of liver tumor and parenchyma

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Kojima, Hiroyuki; Kariya, Shuji; Sawada, Satoshi

    2003-01-01

    The purpose of this study was to quantify pure arterial blood perfusion of liver tumor and parenchyma by using CT perfusion during selective hepatic arteriography. A total of 44 patients underwent liver CT perfusion study by injection of contrast medium via the hepatic artery. CT-perfusion parameters including arterial blood flow, arterial blood volume, and arterial mean transit time in the liver parenchyma and liver tumor were calculated using the deconvolution method. The CT-perfusion parameters and vascularity of the tumor were compared. A complete analysis could be performed in 36 of the 44 patients. For liver tumor and liver parenchyma, respectively, arterial blood flow was 184.6±132.7 and 41.0±27.0 ml/min/100 g, arterial blood volume was 19.4±14.6 and 4.8±4.2 ml/100 g, and arterial mean transit time was 8.9±4.2 and 10.2±5.3 sec. Arterial blood flow and arterial blood volume correlated significantly with the vascularity of the tumor; however no correlation was detected between arterial mean transit time and the vascularity of the tumor. This technique could be used to quantify pure hepatic arterial blood perfusion. (author)

  1. Blood transfusion requirement in surgery for femoral artery aneurysms

    DEFF Research Database (Denmark)

    Levi, N; Schroeder, T V

    1997-01-01

    Audit of blood usage in various surgical specialities have shown that over-ordering of blood is widespread, causing unnecessary pressure on the transfusion facilities and giving growing concern over the expense of cross-matching blood. The aim of this study was to assess the blood transfusion...

  2. No benefit of intraoperative whole blood sequestration and autotransfusion during coronary artery bypass grafting : results of a randomized clinical trial

    NARCIS (Netherlands)

    Ramnath, A N; Naber, H R; de Boer, A; Leusink, J A

    OBJECTIVES: In a randomized clinical trial of patients undergoing elective coronary artery bypass grafting, we evaluated the effect of intraoperative whole blood sequestration and autotransfusion on postoperative blood loss and the use of allogeneic blood products. METHODS: Male patients were

  3. Studies of U in the blood of two population samples

    International Nuclear Information System (INIS)

    Segovia, N.; Olguin, M.E.; Romero, M.

    1986-01-01

    The present work, attempts to establish the statistical distribution of blood uranium in a population of the same community, similar in age and in living patterns. U traces were evaluated by a fission track technique both in whole blood and plasma samples. Dried samples were compressed into pellets and irradiated in a nuclear reactor using the external detector method. For U quantification, standard U samples were used. A comparative sampling of U content in blood samples from a group of radiation exposed workers and another of leukemia patients was also carried out. Results from the sampling groups are reported and discussed. (author)

  4. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  5. Bacterial Isolates from Blood Samples of Patients in University of ...

    African Journals Online (AJOL)

    Bacterial Isolates from Blood Samples of Patients in University of Benin Teaching Hospital Benin City, Edo State, Nigeria. ... The thioglychollate broth was sub cultured onto blood agar plate for anaerobic incubation, while the brain heart infusion broth was sub cultured onto chocolate, blood agar and McConkey agar for ...

  6. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  7. Contribution of the Arterial System and the Heart to Blood Pressure during Normal Aging - A Simulation Study

    NARCIS (Netherlands)

    Maksuti, Elira; Westerhof, Nico; Westerhof, Berend E.; Broomé, Michael; Stergiopulos, Nikos

    2016-01-01

    During aging, systolic blood pressure continuously increases over time, whereas diastolic pressure first increases and then slightly decreases after middle age. These pressure changes are usually explained by changes of the arterial system alone (increase in arterial stiffness and vascular

  8. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...

  9. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  10. Feasibility of arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke

    International Nuclear Information System (INIS)

    Wang Wei; Li Cheng; Liu Zhensheng; Zhang Xinjiang; Zhou Longjiang; Yin Haiyan

    2010-01-01

    Objective: To assess the feasibility of arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke. Methods: Six patients with acute cerebral infarction within 6 hours underwent intraarterial thrombolysis, in which arterial blood bypass was used. A 2.3 F microcatheter was advanced through the clot and two milliliters of contrast was injected beyond the clot that remained stagnant in the major branches. At this point, 20 ml of oxygenated blood from femoral artery was injected for 2 minutes through the microcatheter past the occluding clot. Then, conventional intraarterial thrombolysis, including fibrinolytic agents infusion and mechanical disruption, was performed. Intraarterial thrombolysis and oxygenated blood infusion alternated every 30 minutes. Results: Every patient received arterial blood bypass with average three times (from 1 to 5 times) in the process of the intraarterial thrombolysis, which cost (8.0 ± 3.2) min. Recanalization was achieved in all 6 patients, but minor subarachnoid hemorrhage developed in one patient. All the patients got favorable clinical outcome. The life conditions is excellent in 4 cases and good in 2 cases. Conclusions: Arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke might be feasible, which did not interfere with conventional intraarterial thrombolysis and prolong the operation time significantly but could protect ischemic penumbra. (authors)

  11. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  12. Strength training reduces arterial blood pressure but not sympathetic neural activity in young normotensive subjects

    Science.gov (United States)

    Carter, Jason R.; Ray, Chester A.; Downs, Emily M.; Cooke, William H.

    2003-01-01

    The effects of resistance training on arterial blood pressure and muscle sympathetic nerve activity (MSNA) at rest have not been established. Although endurance training is commonly recommended to lower arterial blood pressure, it is not known whether similar adaptations occur with resistance training. Therefore, we tested the hypothesis that whole body resistance training reduces arterial blood pressure at rest, with concomitant reductions in MSNA. Twelve young [21 +/- 0.3 (SE) yr] subjects underwent a program of whole body resistance training 3 days/wk for 8 wk. Resting arterial blood pressure (n = 12; automated sphygmomanometer) and MSNA (n = 8; peroneal nerve microneurography) were measured during a 5-min period of supine rest before and after exercise training. Thirteen additional young (21 +/- 0.8 yr) subjects served as controls. Resistance training significantly increased one-repetition maximum values in all trained muscle groups (P < 0.001), and it significantly decreased systolic (130 +/- 3 to 121 +/- 2 mmHg; P = 0.01), diastolic (69 +/- 3 to 61 +/- 2 mmHg; P = 0.04), and mean (89 +/- 2 to 81 +/- 2 mmHg; P = 0.01) arterial blood pressures at rest. Resistance training did not affect MSNA or heart rate. Arterial blood pressures and MSNA were unchanged, but heart rate increased after 8 wk of relative inactivity for subjects in the control group (61 +/- 2 to 67 +/- 3 beats/min; P = 0.01). These results indicate that whole body resistance exercise training might decrease the risk for development of cardiovascular disease by lowering arterial blood pressure but that reductions of pressure are not coupled to resistance exercise-induced decreases of sympathetic tone.

  13. Numerical investigation of MHD flow of blood and heat transfer in a stenosed arterial segment

    Energy Technology Data Exchange (ETDEWEB)

    Majee, Sreeparna; Shit, G.C., E-mail: gcs@math.jdvu.ac.in

    2017-02-15

    A numerical investigation of unsteady flow of blood and heat transfer has been performed with an aim to provide better understanding of blood flow through arteries under stenotic condition. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. The heat transfer characteristic has been analyzed by taking into consideration of the dissipation of energy due to applied magnetic field and the viscosity of blood. The vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman–Rachford Alternating Direction Implicit (ADI) scheme. The quantitative profile analysis of velocity, temperature and wall shear stress as well as Nusselt number is carried out over the entire arterial segment. The streamline and temperature contours have been plotted to understand the flow pattern in the diseased artery, which alters significantly in the downstream of the stenosis in the presence of magnetic field. Both the wall shear stress and Nusselt number increases with increasing magnetic field strength. However, wall shear stress decreases and Nusselt number enhances with Reynolds number. The results show that with an increase in the magnetic field strength upto 8 T, does not causes any damage to the arterial wall, but the study is significant for assessing temperature rise during hyperthermic treatment. - Highlights: • Fully numerical simulation is carried out for MHD blood flow in stenosed artery. • Dissipation of energy due to both magnetic field and blood viscosity is considered. • Strong Vortices are observed at the downstream of the stenosis in the arterial wall. • Flow reversal of blood is reduced by applying sufficient magnetic field strength. • Isothermal lines are strongly distorted in the presence of magnetic field strength.

  14. Payload specialist Reinhard Furrer show evidence of previous blood sampling

    Science.gov (United States)

    1985-01-01

    Payload specialist Reinhard Furrer shows evidence of previous blood sampling while Wubbo J. Ockels, Dutch payload specialist (only partially visible), extends his right arm after a sample has been taken. Both men show bruises on their arms.

  15. Investigation of spiral blood flow in a model of arterial stenosis

    OpenAIRE

    Paul, M.C.; Larman, A.

    2009-01-01

    The spiral component of blood flow has both beneficial and detrimental effects in human circulatory system [Stonebridge PA, Brophy CM. Spiral laminar flow in arteries? Lancet 1991; 338: 1360–1]. We investigate the effects of the spiral blood flow in a model of three-dimensional arterial stenosis with a 75% cross-sectional area reduction at the centre by means of computational fluid dynamics (CFD) techniques. The standard κ–ω model is employed for simulation of the blood flow for the...

  16. The pulmonary artery does not participate in the blood supply of lung cancer: experimental and DSA study

    International Nuclear Information System (INIS)

    Han Mingjun; Feng Gansheng; Yang Jianyong; Su Hongying; Zhao Zhongchun

    2000-01-01

    Objective: To investigate whether or not the pulmonary artery participates in the blood supply of lung cancer and its change of morphology and blood flow in lung cancer. Methods: Two different colors of silicone were injected separately into the bronchial and pulmonary arteries of 33 rat models with squamous cell carcinoma of lung. The origin of blood supply of lung cancer and the morphologic change of pulmonary artery were observed under a stereo-microscope. The DSA of bronchial and pulmonary artery were performed simultaneously in 28 patients with lung cancer. Results: The pulmonary branch of rat and patients were reduced,thinned and occluded in the affected lung. The pulmonary artery did not form tumor vessel,and pulmonary blood flow and perfusion were reduced or absent in the affected area. Conclusion: The pulmonary artery did not participate in the blood supply of lung cancer. It is unreasonable to perform transcatheter chemo-embolization for lung cancer via pulmonary artery

  17. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  18. Arterial blood gases during and their dynamic changes after cardiopulmonary resuscitation: A prospective clinical study.

    Science.gov (United States)

    Spindelboeck, Walter; Gemes, Geza; Strasser, Christa; Toescher, Kathrin; Kores, Barbara; Metnitz, Philipp; Haas, Josef; Prause, Gerhard

    2016-09-01

    An arterial blood gas analysis (ABG) yields important diagnostic information in the management of cardiac arrest. This study evaluated ABG samples obtained during out-of-hospital cardiopulmonary resuscitation (OHCPR) in the setting of a prospective multicenter trial. We aimed to clarify prospectively the ABG characteristics during OHCPR, potential prognostic parameters and the ABG dynamics after return of spontaneous circulation (ROSC). ABG samples were collected and instantly processed either under ongoing OHCPR performed according to current advanced life support guidelines or immediately after ROSC and data ware entered into a case report form along with standard CPR parameters. During a 22-month observation period, 115 patients had an ABG analysis during OHCPR. In samples obtained under ongoing CPR, an acidosis was present in 98% of all cases, but was mostly of mixed hypercapnic and metabolic origin. Hypocapnia was present in only 6% of cases. There was a trend towards higher paO2 values in patients who reached sustained ROSC, and a multivariate regression analysis revealed age, initial rhythm, time from collapse to CPR initiation and the arterio-alveolar CO2 difference (AaDCO2) to be associated with sustained ROSC. ABG samples drawn immediately after ROSC demonstrated higher paO2 and unaltered pH and base excess levels compared with samples collected during ongoing CPR. Our findings suggest that adequate ventilation and oxygenation deserve more research and clinical attention in the management of cardiac arrest and that oxygen uptake improves within minutes after ROSC. Hyperventilation resulting in arterial hypocapnia is not a major problem during OHCPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  20. Comparative study of Newtonian physiological blood flow through normal and stenosed carotid artery

    Science.gov (United States)

    Rahman, Mohammad Matiur; Hossain, Md. Anwar; Mamun, Khairuzzaman; Akhter, Most. Nasrin

    2017-06-01

    A numerical simulation is performed to investigate Newtonian physiological flows behavior on three dimensional idealized carotid artery (CA) and single stenosed (75% by area) carotid artery(SCA). The wall vessel is set as rigid during simulation. Bifurcated blood vessel are simulated by using three-dimensional flow analysis. Physiological and parabolic velocity profiles are set out to fix the conditions of inlet boundaries of artery. In other hand, physiological waveform is an important part of compilation and it is successfully done by utilization of Fourier series having sixteen harmonics. The investigation has a Reynolds number range of 94 to 1120. Low Reynolds number k — ω model has been used as governing equation. The investigation has been carried out to characterize the flow behavior of blood in two geometry, namely, (i) Normal carotid artery (CA) and (ii) Stenosed carotid artery (SCA). The Newtonian model has been used to study the physics of fluid. The findings of the two models are thoroughly compared in order to observe there behavioral sequence of flows. The numerical results were presented in terms of velocity, pressure, wall shear stress distributions and cross sectional velocities as well as the streamlines contour. Stenosis disturbs the normal pattern of blood flow through the artery as reduced area. At stenosis region velocity and peak Reynolds number rapidly increase and Reynolds number reach transitional and turbulent region. These flow fluctuation and turbulence have bad effect to the blood vessel which makes to accelerate the progress of stenosis.

  1. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  2. Arterial secondary blood flow patterns visualized with vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Hansen, Jens Munk

    2011-01-01

    This study presents the first quantification and visualisation of secondary flow patterns with vector flow ultrasound. The first commercial implementation of the vector flow method Transverse Oscillation was used to obtain in-vivo, 2D vector fields in real-time. The hypothesis of this study...... was that the rotational direction is constant within each artery. Three data sets of 10 seconds were obtained from three main arteries in healthy volunteers. For each data set the rotational flow patterns were identified during the diastole. Each data set contains a 2D vector field over time and with the vector angles...

  3. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    Science.gov (United States)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  4. Development of extrahepatic arterial blood supply to the liver during hepatic arterial infusion chemotherapy

    International Nuclear Information System (INIS)

    Seki, H.; Kimura, M.; Yoshimura, N.; Yamamoto, S.; Ozaki, T.; Sakai, K.

    1998-01-01

    The aim of this study was to evaluate the correlation of development of the collateral circulation to the liver during hepatic arterial infusion chemotherapy (HAIC) with the presence of hepatic tumours adjacent to the hepatic surface, and with pretreatment occlusion of aberrant hepatic arteries. In 102 patients with unresectable malignant hepatic tumours treated with HAIC using an implantable port system, development of collaterals to the liver was assessed with CT arteriography using the implantable port and pre- and postoperative angiography. Aberrant hepatic arteries, if present, were occluded prior to treatment for hepatic arterial redistribution. Collaterals to the liver were seen in 29 patients, who had 35 areas with collateral perfusion: 22 areas were in the right posterosuperior area, 6 in the left peripheral area and 7 in the right or left lobar area. Collaterals were revealed more frequently in patients with hepatic tumours adjacent to the hepatic surface than in those without hepatic tumours in peripheral areas in the liver (p < 0.0001). In addition, collaterals developed more frequently in patients with an aberrant hepatic arterial anatomy compared with those with conventional anatomy (p = 0.0007). Our results indicated that patients with hepatic tumours adjacent to the hepatic surface and with pretreatment occlusion of aberrant hepatic arteries had the potential to develop collaterals to the liver during HAIC. (orig.)

  5. Analysis of damping characteristics of arterial catheter blood ...

    African Journals Online (AJOL)

    working diagnosis, site of arterial cannula, date and time of insertion, hours since insertion, type of cannula (manufacturer, gauge, length). The CoD was measured using the 'fast flush' method described by .... THC-B & WHR: Design, data collection, analysis, manuscript preparation. JDT: Data collection and analysis.

  6. Resistance training controls arterial blood pressure in rats with L-NAME- induced hypertension.

    Science.gov (United States)

    Araujo, Ayslan Jorge Santos de; Santos, Anne Carolline Veríssimo dos; Souza, Karine dos Santos; Aires, Marlúcia Bastos; Santana-Filho, Valter Joviniano; Fioretto, Emerson Ticona; Mota, Marcelo Mendonça; Santos, Márcio Roberto Viana

    2013-04-01

    Arterial hypertension is a multifactorial chronic condition caused by either congenital or acquired factors. To evaluate the effects of Resistance Training (RT) on arterial pressure, and on vascular reactivity and morphology, of L-NAME-treated hypertensive rats. Male Wistar rats (200 - 250 g) were allocated into Sedentary Normotensive (SN), Sedentary Hypertensive (SH) and Trained Hypertensive (TH) groups. Hypertension was induced by adding L-NAME (40 mg/Kg) to the drinking water for four weeks. Arterial pressure was evaluated before and after RT. RT was performed using 50% of 1RM, 3 sets of 10 repetitions, 3 times per week for four weeks. Vascular reactivity was measured in rat mesenteric artery rings by concentration-response curves to sodium nitroprusside (SNP); phenylephrine (PHE) was also used for histological and stereological analysis. Resistance training inhibited the increase in mean and diastolic arterial pressures. Significant reduction was observed in Rmax (maximal response) and pD2 (potency) of PHE between SH and TH groups. Arteries demonstrated normal intima, media and adventitia layers in all groups. Stereological analysis demonstrated no significant difference in luminal, tunica media, and total areas of arteries in the SH and TH groups when compared to the SN group. Wall-to-lumen ratio of SH arteries was significantly different compared to SN arteries (parteries. RT was able to prevent an increase in blood pressure under the conditions in this study. This appears to involve a vasoconstrictor regulation mechanism and maintenance of luminal diameter in L-NAME induced hypertensive rats.

  7. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  8. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  9. Dietary sodium bicarbonate, cool temperatures, and feed withdrawal: impact on arterial and venous blood-gas values in broilers.

    Science.gov (United States)

    Wideman, R F; Hooge, D M; Cummings, K R

    2003-04-01

    Sodium bicarbonate (NaHCO3) has been used successfully in mammals and birds to alleviate pulmonary hypertension. Experiment 1 was designed to provide measurements of arterial and venous blood-gas values from unanesthetized male broilers subjected to a cool temperature (16 degrees C) challenge and fed either a control diet or the same diet alkalinized by dilution with 1% NaHCO3. The incidences of pulmonary hypertension syndrome (PHS, ascites) for broilers fed the control or bicarbonate diets were 15.5 and 10.5%, respectively (P = 0.36, NS). Non-ascitic broilers fed the control diet were heavier than those fed the bicarbonate diet on d 49 (2,671 vs. 2,484 g, respectively); however, other comparisons failed to reveal diet-related differences in heart weight, pulse oximetry values, electrocardiogram amplitudes, or blood-gas values (P > 0.05). When the data were resorted into categories based on right:total ventricular weight ratios (RV:TV) indicative of normal (RV:TV or = 0.28) pulmonary arterial pressures, broilers with elevated RV:TV ratios had poorly oxygenated arterial blood that was more acidic, had high partial pressure of CO2 (PCO2), and had higher HCO3 concentrations when compared with broilers with normal RV:TV ratios. Experiment 2 was conducted to determine if metabolic variations associated with differences in feed intake or environmental temperature potentially could mask an impact of diet composition on blood-gas values. Male broilers maintained at thermoneutral temperature (24 degrees C) either received feed ad libitum or had the feed withdrawn > or = 12 h prior to blood sampling. Broilers fed ad libitum had lower venous saturation of hemoglobin with O2, higher venous PCO2, and higher arterial HCO3 concentrations than broilers subjected to feed withdrawal. Broilers in experiment 2 fed ad libitum and exposed to cool temperatures (16 degrees C) had lower arterial partial pressure of O2 and higher venous PCO2 than broilers fed ad libitum and maintained at 24

  10. A Pulse Wave Velocity Based Method to Assess the Mean Arterial Blood Pressure Limits of Autoregulation in Peripheral Arteries

    Directory of Open Access Journals (Sweden)

    Ananya Tripathi

    2017-11-01

    Full Text Available Background: Constant blood flow despite changes in blood pressure, a phenomenon called autoregulation, has been demonstrated for various organ systems. We hypothesized that by changing hydrostatic pressures in peripheral arteries, we can establish these limits of autoregulation in peripheral arteries based on local pulse wave velocity (PWV.Methods: Electrocardiogram and plethysmograph waveforms were recorded at the left and right index fingers in 18 healthy volunteers. Each subject changed their left arm position, keeping the right arm stationary. Pulse arrival times (PAT at both fingers were measured and used to calculate PWV. We calculated ΔPAT (ΔPWV, the differences between the left and right PATs (PWVs, and compared them to the respective calculated blood pressure at the left index fingertip to derive the limits of autoregulation.Results: ΔPAT decreased and ΔPWV increased exponentially at low blood pressures in the fingertip up to a blood pressure of 70 mmHg, after which changes in ΔPAT and ΔPWV were minimal. The empirically chosen 20 mmHg window (75–95 mmHg was confirmed to be within the autoregulatory limit (slope = 0.097, p = 0.56. ΔPAT and ΔPWV within a 20 mmHg moving window were not significantly different from the respective data points within the control 75–95 mmHg window when the pressure at the fingertip was between 56 and 110 mmHg for ΔPAT and between 57 and 112 mmHg for ΔPWV.Conclusions: Changes in hydrostatic pressure due to changes in arm position significantly affect peripheral arterial stiffness as assessed by ΔPAT and ΔPWV, allowing us to estimate peripheral autoregulation limits based on PWV.

  11. Study on blood supply of lung metastasis with trans-pulmonary arterial lipiodol infusion

    International Nuclear Information System (INIS)

    Zhou Jianqin; Dong Weihua; Dong Weihua; Ouyang Chang; Chang Heng; Xiao Xiangsheng

    2008-01-01

    Objective: To evaluate the blood supply of pulmonary metastases using small volume of lipiodol through pulmonary arterial infusion. Methods: 10 cases of lung metastasis were enroled including the primary tumors of liver cancer (n=5), renal carcinoma (n=3), chordoma (n=1) and malignant neurofibroma (n=1). Plain CT scan was performed to exclude calcification or ossification within metastasis and then pulmonary arterial DSA was undertaken to evaluate tumor vessels or staining. After pulmonary arteriovenous fistula or other anomalous circulation was excluded by lobar arterial DSA, small volume of lipiodol was infused under fluoroscopy (0.5-1.5 ml for each lobar artery, total volume less than 3.0 ml). CT scan was immediately performed. Blood supply of the pulmonary metastases was assessed according to the accumulation of lipiodol on CT scans. Results: No cases but one experienced cough, expectoration, suffocating or dyspnea. No complication of cerebral or visceral embolism occurred. Totally 27 nodules were studied including 6 nodules with cloudy lipiodol accumulation and 6 nodules with tiny granules of lipiodol accumulation. No enlarged tumor vessel or tumor stain was observed within all 27 nodules on pulmonary arterial DSA. Conclusions: Pulmonary artery supplys only parts of pulmonary metastases, especially those sited at the peripheral region of the lung. Infusion of small volume of lipiodol through pulmonary artery is safe, and the increased density of lung field could return normal after several days. (authors)

  12. Numerical investigation of MHD flow of blood and heat transfer in a stenosed arterial segment

    Science.gov (United States)

    Majee, Sreeparna; Shit, G. C.

    2017-02-01

    A numerical investigation of unsteady flow of blood and heat transfer has been performed with an aim to provide better understanding of blood flow through arteries under stenotic condition. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. The heat transfer characteristic has been analyzed by taking into consideration of the dissipation of energy due to applied magnetic field and the viscosity of blood. The vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman-Rachford Alternating Direction Implicit (ADI) scheme. The quantitative profile analysis of velocity, temperature and wall shear stress as well as Nusselt number is carried out over the entire arterial segment. The streamline and temperature contours have been plotted to understand the flow pattern in the diseased artery, which alters significantly in the downstream of the stenosis in the presence of magnetic field. Both the wall shear stress and Nusselt number increases with increasing magnetic field strength. However, wall shear stress decreases and Nusselt number enhances with Reynolds number. The results show that with an increase in the magnetic field strength upto 8 T, does not causes any damage to the arterial wall, but the study is significant for assessing temperature rise during hyperthermic treatment.

  13. Relationship between vertebral artery blood flow in different head positions and vertigo.

    Science.gov (United States)

    Araz Server, Ela; Edizer, Deniz Tuna; Yiğit, Özgür; Yasak, Ahmet Görkem; Erdim, Çağrı

    2018-01-01

    To identify the vertebral artery blood flow in different head positions in patients with positional vertigo with no specific diagnosis. Patients with history of vestibular symptoms associated with changes in head position were enrolled into the study. Healthy volunteers were evaluated as control group. Doppler ultrasonography examination of the cervical segment of the vertebral arteries was performed under three different head positions: (i) supine position, (ii) head hyperextended and rotated to the right side and (iii) head hyperextended and rotated to the left side. In the study group, right and left vertebral artery blood flow was significantly lower in the ipsilateral hyperextended position compared to standard supine position (respectively p = .014; p = .001), but did not differ significantly when compared between the standard supine and contralateral hyperextended positions (respectively = .959; p = .669). In the control group, left and right vertebral artery blood flow did not differ significantly when the head was hyperextended to the right or left sides compared to standard supine position (p > .05). Our data demonstrated that the etiology of vestibular complaints in patients with undiagnosed positional vertigo might be related to impairment in vertebral artery blood flow according to head positions.

  14. Arterial cord blood lactate at birth correlates with duration of pushing efforts.

    Science.gov (United States)

    Dessolle, Lionel; Lebrec, Jeremie; Daraï, Emile

    2010-01-01

    To evaluate the impact of the duration of pushing efforts on arterial cord blood lactate values. This was a prospective observational study of 124 consecutive normal vaginal deliveries in a tertiary teaching hospital. Arterial cord blood lactate was determined immediately at birth with a test strip method. Univariate and multivariate analyses were performed to check for clinical determinants of lactate levels. The main measure was lactate according to the duration of pushing efforts. Arterial cord lactates increased significantly and were strongly correlated with the duration of pushing efforts, independent of gestational age and birthweight. Women pushing for more than 20 min had higher arterial cord blood lactates (4.9 +/- 1.4 vs. 3.3 +/- 1.16 mM, respectively) and a higher rate of lactates >6 mM (18 vs. 3%) than those pushing for less than 20 min. At normal delivery, arterial cord blood lactates increase significantly with the duration of pushing efforts. Pushing for more than 20 min is associated with an increased risk of metabolic acidosis in the neonate. Further studies are required to evaluate the clinical significance of these observations. 2009 S. Karger AG, Basel.

  15. Extensive monitoring through multiple blood samples in professional soccer players

    DEFF Research Database (Denmark)

    Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter

    2013-01-01

    of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. VO2max decreased towards the end of the season whereas no significant changes were observed in the IE2 test.The regular blood samples from elite soccer players reveal significant changes......ABSTRACT: The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players, and to analyze different blood parameters in relation to seasonal changes in training and match exposure.Blood samples were collected five times during a six...... months period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, players were tested for body composition, VO2max and physical performance by the Yo-Yo intermittent endurance sub-max test (IE2).Multiple variations in blood parameters occurred during...

  16. Renal artery anatomy affects the blood pressure response to renal denervation in patients with resistant hypertension.

    Science.gov (United States)

    Hering, Dagmara; Marusic, Petra; Walton, Antony S; Duval, Jacqueline; Lee, Rebecca; Sata, Yusuke; Krum, Henry; Lambert, Elisabeth; Peter, Karlheinz; Head, Geoff; Lambert, Gavin; Esler, Murray D; Schlaich, Markus P

    2016-01-01

    Renal denervation (RDN) has been shown to reduce blood pressure (BP), muscle sympathetic nerve activity (MSNA) and target organ damage in patients with resistant hypertension (RH) and bilateral single renal arteries. The safety and efficacy of RDN in patients with multiple renal arteries remains unclear. We measured office and 24-hour BP at baseline, 3 and 6 months following RDN in 91 patients with RH, including 65 patients with single renal arteries bilaterally (group 1), 16 patients with dual renal arteries on either one or both sides (group 2) and 10 patients with other anatomical constellations or structural abnormalities (group 3). Thirty nine out of 91 patients completed MSNA at baseline and follow-up. RDN significantly reduced office and daytime SBP in group 1 at both 3 and 6 months follow-up (Pkidney function in any group. While RDN can be performed safely irrespective of the underlying renal anatomy, the presence of single renal arteries with or without structural abnormalities is associated with a more pronounced BP and MSNA lowering effect than the presence of dual renal arteries in patients with RH. However, when patients with dual renal arteries received renal nerve ablation in all arteries there was trend towards a greater BP reduction. Insufficient renal sympathetic nerve ablation may account for these differences. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Certain, D.A.; Brolio, R.; Salomon, G.C.; Carvalho, N.; Barbosa, Z.L.M.

    1972-01-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin 131 I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions [pt

  18. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Certain, D A; Brolio, R; Salomon, G C [Sao Paulo Univ. (Brazil). Faculdade de Saude Publica; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear; Barbosa, Z L.M. [Associacao dos Sanatorios Populares de Campos do Jordao, Brazil

    1972-10-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin /sup 131/I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions.

  19. Are They Bloody Guilty? Blood Doping with Simulated Samples

    Science.gov (United States)

    Stuart, Parker E.; Lees, Kelsey D.; Milanick, Mark A.

    2014-01-01

    In this practice-based lab, students are provided with four Olympic athlete profiles and simulated blood and urine samples to test for illegal substances and blood-doping practices. Throughout the course of the lab, students design and conduct a testing procedure and use their results to determine which athletes won their medals fairly. All of the…

  20. Non-terminal blood sampling techniques in guinea pigs.

    Science.gov (United States)

    Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens

    2014-10-11

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.

  1. Stability of carboxyhemoglobin in stored and mailed blood samples.

    Science.gov (United States)

    Hampson, Neil B

    2008-02-01

    Elevated blood carboxyhemoglobin (COHb) levels are used to confirm a clinical diagnosis of exposure to carbon monoxide (CO) and, in some instances, assess severity of poisoning. However, many hospital laboratories cannot measure COHb because they do not have CO-oximeters. In such instances, blood samples are often sent to outside laboratories or with a transported patient for measurement at the receiving hospital. This study was conducted to assess the stability of COHb in stored and mailed blood samples anticoagulated with heparin. Adult human blood was drawn into standard sample tubes anticoagulated with sodium heparin. Carbon monoxide gas was infused to raise the COHb level to 25% to 35%. Samples were then refrigerated or stored at room temperature, and serial COHb determinations were performed for 28 days. Additional samples were measured after being mailed locally or across the United States and back. No significant changes in COHb levels were seen in samples stored either in refrigeration or at room temperature over a period of 28 days or in samples shipped without refrigeration locally or across the United States. Carboxyhemoglobin levels in whole blood samples anticoagulated with heparin are stable with or without refrigeration for up to 4 weeks. If COHb measurement capability is not available, such samples may be shipped or transported with patients with confidence that the COHb level will be stable when measured at a later time.

  2. The pathology of facial vein blood sampling in mice

    DEFF Research Database (Denmark)

    Hansen, Ket; Harslund, Jakob le Fèvre; Bollen, Peter

    2014-01-01

    vein blood sampling. Therefore, we investigated if this technique was associated with pathological changes of the jaw region. Methods: 43 NMRI mice were subjected to facial vein blood sampling by using the lancet method during 12 months, starting at the age of 8 weeks. The mice were restrained manually......, and the tissue of the jaw was evaluated. Results: In the 23 mice, from which blood samples had been taken 2 days previously, 5 mice had no signs of gross pathological changes, whereas 12 mice had signs of minimal local subcutaneous bleeding and 6 mice had moderate local subcutaneous bleeding. No additional gross...... pathological changes were observed. In the 23 mice, from which blood samples had been taken 4 weeks earlier, no hemorrhage or signs of scar tissue formation could be observed. Histological slides are currently being processed (HE staining) and will be evaluated and discussed....

  3. Gene expression patterns in peripheral blood correlate with the extent of coronary artery disease.

    Directory of Open Access Journals (Sweden)

    Peter R Sinnaeve

    Full Text Available Systemic and local inflammation plays a prominent role in the pathogenesis of atherosclerotic coronary artery disease, but the relationship of whole blood gene expression changes with coronary disease remains unclear. We have investigated whether gene expression patterns in peripheral blood correlate with the severity of coronary disease and whether these patterns correlate with the extent of atherosclerosis in the vascular wall. Patients were selected according to their coronary artery disease index (CADi, a validated angiographical measure of the extent of coronary atherosclerosis that correlates with outcome. RNA was extracted from blood of 120 patients with at least a stenosis greater than 50% (CADi > or = 23 and from 121 controls without evidence of coronary stenosis (CADi = 0. 160 individual genes were found to correlate with CADi (rho > 0.2, P<0.003. Prominent differential expression was observed especially in genes involved in cell growth, apoptosis and inflammation. Using these 160 genes, a partial least squares multivariate regression model resulted in a highly predictive model (r(2 = 0.776, P<0.0001. The expression pattern of these 160 genes in aortic tissue also predicted the severity of atherosclerosis in human aortas, showing that peripheral blood gene expression associated with coronary atherosclerosis mirrors gene expression changes in atherosclerotic arteries. In conclusion, the simultaneous expression pattern of 160 genes in whole blood correlates with the severity of coronary artery disease and mirrors expression changes in the atherosclerotic vascular wall.

  4. PX-18 Protects Human Saphenous Vein Endothelial Cells under Arterial Blood Pressure.

    Science.gov (United States)

    Kupreishvili, Koba; Stooker, Wim; Emmens, Reindert W; Vonk, Alexander B A; Sipkens, Jessica A; van Dijk, Annemieke; Eijsman, Leon; Quax, Paul H; van Hinsbergh, Victor W M; Krijnen, Paul A J; Niessen, Hans W M

    2017-07-01

    Arterial blood pressure-induced shear stress causes endothelial cell apoptosis and inflammation in vein grafts after coronary artery bypass grafting. As the inflammatory protein type IIA secretory phospholipase A 2 (sPLA 2 -IIA) has been shown to progress atherosclerosis, we hypothesized a role for sPLA 2 -IIA herein. The effects of PX-18, an inhibitor of both sPLA 2 -IIA and apoptosis, on residual endothelium and the presence of sPLA 2 -IIA were studied in human saphenous vein segments (n = 6) perfused at arterial blood pressure with autologous blood for 6 hrs. The presence of PX-18 in the perfusion blood induced a significant 20% reduction in endothelial cell loss compared to veins perfused without PX18, coinciding with significantly reduced sPLA 2 -IIA levels in the media of the vein graft wall. In addition, PX-18 significantly attenuated caspase-3 activation in human umbilical vein endothelial cells subjected to shear stress via mechanical stretch independent of sPLA 2 -IIA. In conclusion, PX-18 protects saphenous vein endothelial cells from arterial blood pressure-induced death, possibly also independent of sPLA 2 -IIA inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Comparison of arterial and venous blood biomarker levels in chronic obstructive pulmonary disease [v1; ref status: indexed, http://f1000r.es/9x

    Directory of Open Access Journals (Sweden)

    Emer Kelly

    2013-04-01

    Full Text Available Purpose: The development of novel biomarkers is an unmet need in chronic obstructive pulmonary disease (COPD. Arterial blood comes directly from the lung and venous blood drains capillary beds of the organ or tissue supplied. We hypothesized that there would be a difference in levels of the biomarkers metalloproteinase 9 (MMP-9, vascular endothelial growth factor A (VEGF-A and interleukin 6 (IL-6 in arterial compared with venous blood.  Methods: Radial artery and brachial vein blood samples were taken simultaneously in each of 12 patients with COPD and seven controls with normal lung function. Circulating immunoreactive MMP-9, VEGF-A and IL-6 levels in serum were measured using quantitative enzyme-linked immunosorbent assays. Results were compared using a Student’s paired t test. The study was powered to determine whether significant differences in cytokine levels were present between paired arterial and venous blood samples.   Results: In the 12 patients with COPD, four were female, and age ranged 53-85 years, mean age 69 years. Three patients in the control group were female, with age range 46-84 years, mean age 64.7 years. In the COPD group, three patients had mild, five moderate and four severe COPD. No significant difference was found between arterial and venous levels of MMP-9, VEGF-A or IL-6.  Conclusions: In this pilot study, levels of the measured biomarkers in arterial compared with venous blood in both COPD patients and healthy controls did not differ. This suggests that as we continue to chase the elusive biomarker in COPD as a potential tool to measure disease activity, we should focus on venous blood for this purpose.

  6. [Multicenter clinical study on umbilical cord arterial blood gas parameters for diagnosis of neonatal asphyxia].

    Science.gov (United States)

    2010-09-01

    To obtain the normal range of statistics of umbilical artery blood gas parameters of the newborns for diagnosis of neonatal asphyxia. From March 2008 through September 2009, 17 978 singleton term appropriate for gestational age (AGA) or larger than gestational age (LGA) newborns in six hospitals of five provinces/autonomous regions were consecutively enrolled in this prospective study. The normal ranges of umbilical artery blood gas parameters were obtained from 17 645 newborns with 1 min Apgar score ≥ 8. The correlations between umbilical artery blood pH, BE and prenatal high-risk factors, Apgar scores, and organ damage were analyzed. The diagnostic criteria for asphyxia included the following: (1) Having high-risk factors that might cause asphyxia; (2) 1 min Apgar score ≤ 7 (the respiratory depression must be present); (3) At least one organ showed evidence of hypoxic damage; (4) Other causes of low Apgar score were excluded. The study focused on the distributive characteristics of umbilical artery blood pH (clinically corrected by Eisenberg formula) and BE values of the asphyxiated and non-asphyxiated cases in low Apgar score group, as well as the sensitivity and specificity of different selected pH and BE threshold spots within their distributing ranges. Among the 17 978 singleton term AGA or LGA newborns, the statistically normal range of umbilical artery blood pH, BE for the 17 645 cases with 1 min Apgar scores ≥ 8 were 7.20 ± 0.20 (x(-) ± 1.96 s) and -7.64 ± 10.02 (x(-) ± 1.96 s), respectively. The pH well correlated positively with BE (r = 0.734, P blood pH and BE values correlated positively with the Apgar scores. The umbilical artery blood pH and BE values correlated negatively with organ damage (r = 1, the P values = 0.000 for both). Among the 333 low Apgar score cases, the umbilical artery blood pH corrected values and BE values of the asphyxiated group (163 cases) were 7.011 ± 0.09 (x(-) ± s) and -14.98 ± 2.99 (x(-) ± s), being lower than

  7. Astronaut Joseph Kerwin takes blood sample from Astronaut Charles Conrad

    Science.gov (United States)

    1973-01-01

    Scientist-Astronaut Joseph P. Kerwin (right), Skylab 2 science pilot and a doctor of medicine, takes a blood sample from Astronaut Charles Conrad Jr., Sylab 2 commander, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1 and 2 space station cluster in Earth orbit. The blood sampling was part of the Skylab Hematology and Immunology Experiment M110 series.

  8. C-14-activity incorporation into the protein of fetal organs of guinea pigs with different maternal placental blood flow and fetal arterial O2-saturation

    International Nuclear Information System (INIS)

    Duenzl, B.

    1981-01-01

    In anaesthesised gravid guinea-pigs the dilate, end section of a placental radial artery was connected to the A.carotis via a flow meter and a throttle in order to measure and widely alter the maternal placental blood flow. Blood samples are taken from the fetal A.carotis, the fetal arterial O 2 -saturation and the Hb-content were determined. By altering the maternal placental blood circulation the fetal arterial O 2 -concentration can stabilised at various levels. In order to study the protein synthesis, under these conditions one infused 185 kBq C-14-leucine over a period of 3 hours into the jugular vein of the fetus. During infusion the radioactive concentrations in whole plasma and plasma water were measured. After the infusion the radioactive concentrations in the tissue fluid, the intracellular fluid and the acid-insoluble tissue fraction (protein) of the heart, kidenys, liver, the muscles of the upper end lower part of the body, the brain and the placenta were measured. The following deductions were drawn from the findings: The maternal placental blood flow vitally influences the activity incorporation per activity concentration in the plasma water. These findings agree with the hypotheses that the maternal blood circulation has an essential influence on the fetal proteins synthesis and that this influence can be attributed to the connection between placenta connection blood flow and oxygen saturation of fetal arterial blood. (orig.) [de

  9. Cantilever arrayed blood pressure sensor for arterial applanation tonometry.

    Science.gov (United States)

    Lee, Byeungleul; Jeong, Jinwoo; Kim, Jinseok; Kim, Bonghwan; Chun, Kukjin

    2014-03-01

    The authors developed a cantilever-arrayed blood pressure sensor array fabricated by (111) silicon bulk-micromachining for the non-invasive and continuous measurement of blood pressure. The blood pressure sensor measures the blood pressure based on the change in the resistance of the piezoresistor on a 5-microm-thick-arrayed perforated membrane and 20-microm-thick metal pads. The length and the width of the unit membrane are 210 and 310 microm, respectively. The width of the insensible zone between the adjacent units is only 10 microm. The resistance change over contact force was measured to verify the performance. The good linearity of the result confirmed that the polydimethylsiloxane package transfers the forces appropriately. The measured sensitivity was about 4.5%/N. The maximum measurement range and the resolution of the fabricated blood pressure sensor were greater than 900 mmHg (= 120 kPa) and less than 1 mmHg (= 133.3 Pa), respectively.

  10. Radionuclide scanning in a study of the pulmonary blood flow with the open arterial canal

    International Nuclear Information System (INIS)

    Rizaev, M.N.; Gulyamov, D.S.; Khodzhibekov, M.Kh.; Anvarov, M.A.

    1980-01-01

    Characteristic features of the distribution of the arterial pulmonary blood flow have been studied in 32 patients with the open arterial flow by lung scanning with albumin macroaggregate and 131 I. Research was conducted using the gamma-Ochamber ''Fo Gamma LFV'' and the scanner ''Magnaskaner 500I''. Disordered distribution of the pulmonary blood flow expressed in its unilateral decrease was detected in 17 patients (52.9%). A higher frequency of pulmonary hypertension was noted in these patients versus those with a relatively normal distribution of the pulmonary blood flow. A severe course of the disease was observed in high pulmonary hypertension combined with sharp suppression of the blood flow in one of the lungs or with signs of the shift from the right to the left side

  11. An automated blood sampling system used in positron emission tomography

    International Nuclear Information System (INIS)

    Eriksson, L.; Bohm, C.; Kesselberg, M.

    1988-01-01

    Fast dynamic function studies with positron emission tomography (PET), has the potential to give accurate information of physiological functions of the brain. This capability can be realised if the positron camera system accurately quantitates the tracer uptake in the brain with sufficiently high efficiency and in sufficiently short time intervals. However, in addition, the tracer concentration in blood, as a function of time, must be accurately determined. This paper describes and evaluates an automated blood sampling system. Two different detector units are compared. The use of the automated blood sampling system is demonstrated in studies of cerebral blood flow, in studies of the blood-brain barrier transfer of amino acids and of the cerebral oxygen consumption. 5 refs.; 7 figs

  12. Changes in cerebral artery blood flow velocity after intermittent cerebrospinal fluid drainage.

    OpenAIRE

    Kempley, S T; Gamsu, H R

    1993-01-01

    Doppler ultrasound was used to measure blood flow velocity in the anterior cerebral artery of six premature infants with posthaemorrhagic hydrocephalus, before and after intermittent cerebrospinal fluid (CSF) drainage, on 23 occasions. There was a significant increase in mean blood flow velocity after the drainage procedures (+5.6 cm/s, 95% confidence interval +2.9 to +8.3 cm/s), which was accompanied by a decrease in velocity waveform pulsatility. CSF pressure also fell significantly. In pat...

  13. Dried blood spots of pooled samples for RHD gene screening in blood donors of mixed ancestry.

    Science.gov (United States)

    Silva-Malta, M C F; Araujo, N C Fidélis; Vieira, O V Neves; Schmidt, L Cayres; Gonçalves, P de Cassia; Martins, M Lobato

    2015-10-01

    In this study, we present a strategy for RHD gene screening based on real-time polymerase chain reaction (PCR) using dried blood spots of pooled samples. Molecular analysis of blood donors may be used to detect RHD variants among the presumed D-negative individuals. RHD genotyping using pooled samples is a strategy to test a large number of samples at a more reasonable cost. RHD gene detection based on real-time PCR using dried blood spots of pooled samples was standardised and used to evaluate 1550 Brazilian blood donors phenotyped as RhD-negative. Positive results were re-evaluated by retesting single samples using real-time PCR and conventional multiplex PCR to amplify five RHD-specific exons. PCR-sequence-specific primers was used to amplify RHDψ allele. We devised a strategy for RHD gene screening using dried blood spots of five pooled samples. Among 1550 serologically D-negative blood donors, 58 (3.74%) had the RHD gene. The non-functional RHDψ allele was detected in 47 samples (3.02%). The present method is a promising strategy to detect the RHD gene among presumed RhD-negative blood donors, particularly for populations with African ancestry. © 2015 British Blood Transfusion Society.

  14. Arterial Blood Pressure Induces Transient C4b-Binding Protein in Human Saphenous Vein Grafts.

    Science.gov (United States)

    Kupreishvili, Koba; Meischl, Christof; Vonk, Alexander B A; Stooker, Wim; Eijsman, Leon; Blom, Anna M; Quax, Paul H A; van Hinsbergh, Victor W M; Niessen, Hans W M; Krijnen, Paul A J

    2017-05-01

    Complement is an important mediator in arterial blood pressure-induced vein graft failure. Previously, we noted activation of cell protective mechanisms in human saphenous veins too. Here we have analyzed whether C4b-binding protein (C4bp), an endogenous complement inhibitor, is present in the vein wall. Human saphenous vein segments obtained from patients undergoing coronary artery bypass grafting (n = 55) were perfused in vitro at arterial blood pressure with either autologous blood for 1, 2, 4, or 6 hr or with autologous blood supplemented with reactive oxygen species scavenger N-acetylcysteine. The segments were subsequently analyzed quantitatively for presence of C4bp and complement activation product C3d using immunohistochemistry. Perfusion induced deposition of C3d and C4bp within the media of the vessel wall, which increased reproducibly and significantly over a period of 4 hr up to 3.8% for C3d and 81% for C4bp of the total vessel area. Remarkably after 6 hr of perfusion, the C3d-positive area decreased significantly to 1.3% and the C4bp-positive area to 19% of the total area of the vein. The areas positive for both C4bp and C3d were increased in the presence of N-acetylcysteine. Exposure to arterial blood pressure leads to a transient presence of C4bp in the vein wall. This may be part of a cell-protective mechanism to counteract arterial blood pressure-induced cellular stress and inflammation in grafted veins. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Blood sampling and hemolysis affect concentration of plasma metabolites

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Pedersen, Lene Juul; Jensen, Margit Bak

    2012-01-01

    design and blood was collected after restraint via vein puncture 1, 4, 11, and 23 h after morning feeding. Plasma samples were categorized as without or with minor or major hemolysis [clear (n = 218), yellow (n = 97), or red (n = 37)] upon centrifugation. Plasma NEFA (P ...Two experiments were carried out to reveal and quantify plasma metabolites that are sensitive to hemolysis and animal stress due to the blood sampling procedure (vein puncture vs. catheter). In Exp. 1, 48 sows were fed 4 diets either once (0800 h) or twice daily (0800 h and 1500 h) in a crossover......, a subset of samples from 24 sows fed twice daily in Exp. 1 was combined with data obtained from 30 sows sampled using jugular vein catheters. All sows in Exp. 2 were fed twice daily (0800 h and 1500 h) and blood samples collected repeatedly 1, 4, 11, and 23 h after morning feeding (other conditions were...

  16. The phosphodiesterase 3 inhibitor cilostazol dilates large cerebral arteries in humans without affecting regional cerebral blood flow

    DEFF Research Database (Denmark)

    Birk, Steffen; Kruuse, Christina Rostrup; Petersen, Kenneth A

    2004-01-01

    in the middle cerebral arteries (VMCA) was measured with transcranial Doppler, and the superficial temporal and radial arteries diameters were measured with ultrasonography. During the 4-hour observation period, there was no effect on systolic blood pressure (P = 0.28), but diastolic blood pressure decreased...

  17. Hemoglobin, hematocrit, and changes in cerebral blood flow : The Second Manifestations of ARTerial disease-Magnetic Resonance study

    NARCIS (Netherlands)

    van der Veen, Pieternella H.; Muller, Majon; Vincken, Koen L.; Westerink, Jan; Mali, Willem P. T. M.; van der Graaf, Yolanda; Geerlings, Mirjam I.; Doevendans, PAFM

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease

  18. Whole body clearance of norepinephrine. The significance of arterial sampling and of surgical stress

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Madsbad, S

    1983-01-01

    The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively, in the ......The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively...

  19. ANGIOGRAPHIC ANATOMY OF THE MAJOR ABDOMINAL ARTERIAL BLOOD SUPPLY IN THE DOG.

    Science.gov (United States)

    Culp, William T N; Mayhew, Philipp D; Pascoe, Peter J; Zwingenberger, Allison

    2015-01-01

    Vascular-based interventional radiology (IR) procedures are being more regularly performed in veterinary patients for both diagnostic and therapeutic purposes. A complete description of the fluoroscopic arterial anatomy of the canine abdominal cavity has not been published. This information is essential for performance of IR procedures to allow for improved preparation before and during a particular procedure. The primary purpose of this study was to provide a fluoroscopic description of the vascular branching from the abdominal aorta in a ventro-dorsal projection with a secondary goal of producing pictorial reference images of the major abdominal arterial blood vessels. Five healthy female hound type dogs were enrolled and underwent fluoroscopic arteriography. During fluoroscopy, both nonselective and selective arteriography were performed. The nonselective arteriograms were obtained in the aorta at four locations: cranial to the celiac artery, cranial to the renal arteries, cranial to the caudal mesenteric artery, and cranial to the branching of the external iliac arteries. Selective arteriography was conducted by performing injections into the following arteries: celiac, splenic, common hepatic, cranial mesenteric, left and right renal, and caudal mesenteric. Fluoroscopic arteriography allowed for excellent characterization of the aortic ostia and the location of the lower order vascular branches. Future evaluation of vascular-based treatment options will likely increase as the understanding of the normal and pathologic anatomy improves. © 2015 American College of Veterinary Radiology.

  20. Renal artery blood flow assessed by video dilution technique before and after percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Lantz, B.M.T.; Link, D.P.; Lewis, E.L.; Foerster, J.M.; Lee, G.

    1981-01-01

    Successful percutaneous transluminal angioplasty was performed in 3 cases of renal artery stenosis where the effect upon renal blood flow was quantified by video dilution technique. This technique adds important information to pressure gradients and renin assays obtained during the dilatation procedure. (Auth.)

  1. Arterial blood pressure changes in acute T. brucei infection of dogs ...

    African Journals Online (AJOL)

    The aim of this study is to find out the usefulness of serial arterial blood pressure measurements in predicting severity and outcome of acute Trypanosoma brucei infection in dogs. Twenty adult dogs of mixed sexes and aged between 2 and 5 years were used for this study. The dogs were of good cardiac health and were ...

  2. Arterial blood gases and oxygen content in climbers on Mount Everest

    NARCIS (Netherlands)

    Grocott, Michael P. W.; Martin, Daniel S.; Levett, Denny Z. H.; McMorrow, Roger; Windsor, Jeremy; Montgomery, Hugh E.; Ahuja, V.; Aref-Adib, G.; Burnham, R.; Chisholm, A.; Clarke, K.; Coates, D.; Coates, M.; Cook, D.; Cox, M.; Dhillon, S.; Dougall, C.; Doyle, P.; Duncan, P.; Edsell, M.; Edwards, L.; Evans, L.; Gardiner, P.; Grocott, M.; Gunning, P.; Hart, N.; Harrington, J.; Harvey, J.; Holloway, C.; Howard, D.; Hurlbut, D.; Imray, C.; Ince, C.; Jonas, M.; van der Kaaij, J.; Khosravi, M.; Kolfschoten, N.; Levett, D.; Luery, H.; Luks, A.; Martin, D.; McMorrow, R.; Meale, P.; Mitchell, K.; Montgomery, H.; Morgan, G.; Morgan, J.; Murray, A.; Mythen, M.; Newman, S.

    2009-01-01

    BACKGROUND: The level of environmental hypobaric hypoxia that affects climbers at the summit of Mount Everest (8848 m [29,029 ft]) is close to the limit of tolerance by humans. We performed direct field measurements of arterial blood gases in climbers breathing ambient air on Mount Everest. METHODS:

  3. Unilateral renal artery stenosis and hypertension. II. Angiographic findings correlated with blood pressure response after surgery

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I; Bergentz, S E; Ericsson, B F; Dymling, J F; Hansson, B G; Hoekfelt, B [Department of Diagnostic Radiography, Surgery and Endocrinology, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    The findings at preoperative nephroanigiography of 42 hypertensive patients with unilateral renal artery stenosis or occlusion were correlated with the blood pressure response following surgery and also with the preoperative renal vein renin activity ratio. A stenosis reducing luminal area by at least 90 per cent (or occlusion) and the presence of collateral circulation are considered to be highly suggestive of renovascular hypertension.

  4. A 2D nonlinear multiring model for blood flow in large elastic arteries

    Science.gov (United States)

    Ghigo, Arthur R.; Fullana, Jose-Maria; Lagrée, Pierre-Yves

    2017-12-01

    In this paper, we propose a two-dimensional nonlinear ;multiring; model to compute blood flow in axisymmetric elastic arteries. This model is designed to overcome the numerical difficulties of three-dimensional fluid-structure interaction simulations of blood flow without using the over-simplifications necessary to obtain one-dimensional blood flow models. This multiring model is derived by integrating over concentric rings of fluid the simplified long-wave Navier-Stokes equations coupled to an elastic model of the arterial wall. The resulting system of balance laws provides a unified framework in which both the motion of the fluid and the displacement of the wall are dealt with simultaneously. The mathematical structure of the multiring model allows us to use a finite volume method that guarantees the conservation of mass and the positivity of the numerical solution and can deal with nonlinear flows and large deformations of the arterial wall. We show that the finite volume numerical solution of the multiring model provides at a reasonable computational cost an asymptotically valid description of blood flow velocity profiles and other averaged quantities (wall shear stress, flow rate, ...) in large elastic and quasi-rigid arteries. In particular, we validate the multiring model against well-known solutions such as the Womersley or the Poiseuille solutions as well as against steady boundary layer solutions in quasi-rigid constricted and expanded tubes.

  5. Reciprocal Influence of Slow Waves Extracted in Intracranial Pressure, Arterial Pressure and Cerebral Blood Velocity Signals

    National Research Council Canada - National Science Library

    Cervenansky, F

    2001-01-01

    ...), and arterial blood pressure (ABP). To clarify the links, we compared two frequency methods based on coherence function to estimate the influence of ICP, ABP, and CBV on couples, respectively CBV-ABP, ICP-CBV and ICP-ABP, of slow waves...

  6. A fast analysis method for non-invasive imaging of blood flow in individual cerebral arteries using vessel-encoded arterial spin labelling angiography

    Science.gov (United States)

    Chappell, Michael A.; Okell, Thomas W.; Payne, Stephen J.; Jezzard, Peter; Woolrich, Mark W.

    2012-01-01

    Arterial spin labelling (ASL) MRI offers a non-invasive means to create blood-borne contrast in vivo for dynamic angiographic imaging. By spatial modulation of the ASL process it is possible to uniquely label individual arteries over a series of measurements, allowing each to be separately identified in the resulting angiographic images. This separation requires appropriate analysis for which a general Bayesian framework has previously been proposed. Here this framework is adapted for clinical dynamic angiographic imaging. This specifically addresses the issues of computational speed of the algorithm and the robustness required to deal with real patient data. An algorithm is proposed that can incorporate planning information about the arteries being imaged whilst adapting for subsequent patient movement. A fast maximum a posteriori solution is adopted and shown to be only marginally less accurate than Monte Carlo sampling under simulation. The final algorithm is demonstrated on in vivo data with analysis on a time scale of the order of 10 min, from both a healthy control and a patient with a vertebro-basilar occlusion. PMID:22322066

  7. [Evaluation of the arterial blood flow parameters in the eye of myopic patients].

    Science.gov (United States)

    Mrugacz, Małgorzata; Bryl, Anna

    2013-04-01

    Myopia is a common refractive defect. Has a good vision from near and deterioration of vision with increasing distance. The main reason for its occurrence is too long axis of the eyeball. The consequence of elongation of the eyeball is the development of degenerative changes in the retina. Despite much research has failed to clearly identify the causes of degenerative changes in those short-sighted. The aim of the study was to evaluate the maximum and minimum speed in arterial blood vessels of the eye in people with myopia. The study included 70 patients (138 eyes), 53 women and 17 men, aged from 18 to 79 years, with myopia of -0.25 to -18.0 Dsph and length of the eyeball from 22.61 to 33.36 mm. Depending on the kind and the degree of the progress of degenerative changes, patients were divided in 4 groups: I - without degenerative changes on the fundus (n=32; K-23, M-9); II- with the short-sighted sickle (n=20; K-14, M-6); Ill - with the structure thinned down of the retina, accompanying the short-sighted sickle (n = 8; K-6, M-2); IV - with extensive choroidal-retina disappearances in the fundus (n = 10; K-7, M-3). In all individuals enrolled underwent Color Doppler ultrasound with apparatus SSA 770A Toshiba Aplio with linear probe frequency 12 MHz, judging maximum (Vmax) and minimum (Vmin) speed in the arteries of the eye: ophthalmic artery (OA), central retinal artery (CRA) and short posterior ciliary arteries (SPCA) located on the nasal and temporal side of the optic disc. The results were statistically analyzed. No statistically significant relationship between the nature of degenerative changes of the eye, and blood velocity in the OA. There was a increase in Vmax and Vmin blood in OA in Group IV, but these changes were not statistically significant. Statistically significant correlation was observed while in the CRA. With a decrease in Vmax and Vmin of blood flowing through a vessel exacerbation of retinal degeneration. Vmax and Vmin changes in the blood did

  8. Evaluation of arterial digital blood flow using Doppler ultrasonography in healthy dairy cows.

    Science.gov (United States)

    Müller, H; Heinrich, M; Mielenz, N; Reese, S; Steiner, A; Starke, A

    2017-06-06

    Local circulatory disturbances have been implicated in the development of foot disorders in cattle. The goals of this study were to evaluate the suitability of the interdigital artery in the pastern region in both hind limbs using pulsed-wave (PW) Doppler ultrasonography and to investigate quantitative arterial blood flow variables at that site in dairy cows. An Esaote MyLabOne ultrasound machine with a 10-MHz linear transducer was used to assess blood flow in the interdigital artery in the pastern region in both hind limbs of 22 healthy German Holstein cows. The cows originated from three commercial farms and were restrained in a standing hoof trimming chute without sedation. A PW Doppler signal suitable for analysis was obtained in 17 of 22 cows. The blood flow profiles were categorised into four curve types, and the following quantitative variables were measured in three uniform cardiac cycles: vessel diameter, pulse rate, maximum systolic velocity, maximum diastolic velocity, end-diastolic velocity, reverse velocity, maximum time-averaged mean velocity, blood flow rate, resistance index and persistence index. The measurements did not differ among cows from the three farms. Maximum systolic velocity, vessel diameter and pulse rate did not differ but other variables differed significantly among blood flow profiles. Differences in weight-bearing are thought to be responsible for the normal variability of blood flow profiles in healthy cows. The scanning technique used in this report for evaluation of blood flow in the interdigital artery appears suitable for further investigations in healthy and in lame cows.

  9. Induced renal artery stenosis in rabbits: magnetic resonance imaging, angiography, and radionuclide determination of blood volume and blood flow

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Tobin, M.; LeVeen, R.; Tomaczewski, J.; Alavi, A.; Staum, M.; Kundel, H.

    1988-01-01

    To investigate the ability of MRI to detect alterations due to renal ischemia, a rabbit renal artery stenosis (RAS) model was developed. Seven rabbits had RAS induced by surgically encircling the artery with a polyethylene band which had a lumen of 1 mm, 1 to 2 weeks prior to imaging. The stenosis was confirmed by angiography, and the rabbits were then imaged in a 1.4 T research MRI unit. T1 was calculated using four inversion recovery sequences with different inversion times. Renal blood flow, using 113 Sn-microspheres, and regional water content by drying were then measured. The average T1 of the inner medulla was shorter for the ischemia (1574 msec) than for the contralateral kidney (1849 msec), while no change ws noted in the cortex. Ischemic kidneys had less distinct outer medullary zones on IR images with TI = 600 msec than did contralateral or control kidneys. Blood flow to both the cortex and medulla were markedly reduced in ischemic kidneys compared with contralateral kidneys (119.5 vs. 391 ml/min/100 gm for cortex and 19.8 vs. 50.8 ml/min/100 gm for medulla). Renal water and blood content were less affected. Our rabbit model of renal artery stenosis with MRI, radionuclide, and angiographic correlation has the potential to increase our understanding of MR imaging of the rabbit kidney

  10. Preanalytic Factors Associated With Hemolysis in Emergency Department Blood Samples.

    Science.gov (United States)

    Phelan, Michael P; Reineks, Edmunds Z; Schold, Jesse D; Hustey, Frederic M; Chamberlin, Janelle; Procop, Gary W

    2018-02-01

    - Hemolysis of emergency department blood samples is a common occurrence and has a negative impact on health care delivery. - To determine the effect of preanalytic factors (straight stick, intravenous [IV] line, needle gauge, location of blood draw, syringe versus vacuum tube use, tourniquet time) on hemolysis in emergency department blood samples. - A single 65 000-visit emergency department's electronic health record was queried for emergency department potassium results and blood draw technique for all samples obtained in calendar year 2014, resulting in 54 531 potassium results. Hemolyzed potassium was measured by hemolysis index. Comparisons of hemolysis by sampling technique were conducted by χ 2 tests. - Overall hemolysis was 10.0% (5439 of 54 531). Hemolysis among samples obtained from straight stick was significantly less than among those obtained with IV line (5.4% [33 of 615] versus 10.2% [4821 of 47 266], P < .001). For IV-placed blood draws, antecubital location had a statistically significant lower overall hemolysis compared with other locations: 7.4% (2117 of 28 786) versus 14.6% (2622 of 17 960) ( P < .001). For blood drawn with a syringe compared with vacuum, hemolysis was 13.0% (92 of 705) and 11.0% (1820 of 16 590), respectively ( P = .09, not significant). For large-gauge IV blood draws versus smaller-gauge IV lines, a lower hemolysis was also observed (9.3% [3882 of 41 571] versus 16.7% [939 of 5633]) ( P < .001). For IV-drawn blood with tourniquet time less than 60 seconds, hemolysis was 10.3% (1362 of 13 162) versus 13.9% for more than 60 seconds (532 of 3832), P < .001. - This study confirmed previous findings that straight stick and antecubital location are significantly associated with reduced hemolysis and indicated that shorter tourniquet time and larger gauge for IV draws were significantly associated with lower hemolysis.

  11. Allergic rhinitis and arterial blood pressure: a population-based study.

    Science.gov (United States)

    Sakallioglu, O; Polat, C; Akyigit, A; Cetiner, H; Duzer, S

    2018-05-01

    To investigate the likelihood of allergic rhinitis and potential co-morbidities, and to assess whether allergic rhinitis is associated with arterial blood pressure and hypertension. In this population-based study, 369 adults with allergic rhinitis and asthma were assessed via a questionnaire and immunoglobulin E levels. There were four groups: control (n = 90), allergic rhinitis (n = 99), asthma (n = 87) and hypertension (n = 93). Arterial blood pressure was measured in all groups. There were no significant differences in systolic or diastolic blood pressure between males and females in any group. Pairwise comparisons revealed no significant differences between: the control and allergic rhinitis groups, the control and asthma groups, or the allergic rhinitis and asthma groups. The systolic and diastolic blood pressure values of males and females were significantly higher in the hypertension group than the allergic rhinitis group. There were no significant differences in systolic blood pressure or diastolic blood pressure for seasonal and perennial allergic rhinitis patients. Rhinitis was not associated with increased blood pressure. Allergic rhinitis can coincide with asthma and hypertension. The findings do not support the need for blood pressure follow up in allergic rhinitis patients.

  12. Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.

    Science.gov (United States)

    Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe

    2017-07-01

    After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.

  13. Roles of Arterial Stiffness and Blood Pressure in Hypertension-Associated Cognitive Decline in Healthy Adults.

    Science.gov (United States)

    Hajjar, Ihab; Goldstein, Felicia C; Martin, Greg S; Quyyumi, Arshed A

    2016-01-01

    Although there is strong evidence that hypertension leads to cognitive decline, especially in the executive domain, the relationship between blood pressure and cognition has been conflicted. Hypertension is characterized by blood pressure elevation and increased arterial stiffness. We aimed at investigating whether arterial stiffness would be superior to blood pressure in predicting cognitive decline and explaining the hypertension-executive decline association. A randomly selected asymptomatic population (n=591, age=49.2 years, 70% women, 27% black, and education=18 years) underwent annual vascular and cognitive assessments. Cognition was assessed using computerized versions commonly used cognitive tests, and principal component analysis was used for deriving cognitive scores for executive function, memory, and working memory. Arterial stiffness was measured by carotid-femoral pulse wave velocity (PWV). Higher PWV, but not blood pressure, was associated with a steeper decline in executive (P=0.0002), memory (P=0.05), and working memory (P=0.02) scores after adjusting for demographics, education, and baseline cognitive performance. This remained true after adjusting for hypertension. Hypertension was associated with greater decline in executive score (P=0.0029) and those with combined hypertension and elevated PWV (>7 m/s) had the greatest decline in executive score (P value hypertension×PWV=0.02). PWV explained the association between hypertension and executive function (P value for hypertension=0.0029 versus 0.24 when adjusting for PWV). In healthy adults, increased arterial stiffness is superior to blood pressure in predicting cognitive decline in all domains and in explaining the hypertension-executive function association. Arterial stiffness, especially in hypertension, may be a target in the prevention of cognitive decline. © 2015 American Heart Association, Inc.

  14. Evaluation of factor for one-point venous blood sampling method based on the causality model

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Onishi, Hideo; Kobara, Kouichi; Sasaki, Fumie; Watanabe, Haruo; Nagaki, Akio; Mimura, Hiroaki

    2009-01-01

    One-point venous blood sampling method (Mimura, et al.) can evaluate the regional cerebral blood flow (rCBF) value with a high degree of accuracy. However, the method is accompanied by complexity of technique because it requires a venous blood Octanol value, and its accuracy is affected by factors of input function. Therefore, we evaluated the factors that are used for input function to determine the accuracy input function and simplify the technique. The input function which uses the time-dependent brain count of 5 minutes, 15 minutes, and 25 minutes from administration, and the input function in which an objective variable is used as the artery octanol value to exclude the venous blood octanol value are created. Therefore, a correlation between these functions and rCBF value by the microsphere (MS) method is evaluated. Creation of a high-accuracy input function and simplification of technique are possible. The rCBF value obtained by the input function, the factor of which is a time-dependent brain count of 5 minutes from administration, and the objective variable is artery octanol value, had a high correlation with the MS method (y=0.899x+4.653, r=0.842). (author)

  15. SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y; Johnston, M; Whitlow, C [Wake Forest School of Medicine, Winston-salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min with a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.

  16. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Luedemann, Lutz [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiotherapy; Nafz, B.; Persson, P. [Charite - Universitaetsmedizin Berlin (Germany). Inst. for Vegetative Physiology; Elsner, F. [Krankenhaus am Urban, Berlin (Germany). Dept. of Anesthesiology; Grosse-Siestrup, C.; Meissler, M. [Charite - Universitaetsmedizin Berlin (Germany). Experimental Animal Unit; Gutberlet, M. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Univ. Leipzig/ Leipzig Heart Center (Germany). Dept. of Diagnostic and Interventional Radiology; Lengsfeld, P.; Voth, M. [Bayer-Schering Pharma AG, Berlin (Germany). Global Medical Affairs Diagnostic Imaging

    2011-03-15

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  17. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    International Nuclear Information System (INIS)

    Luedemann, Lutz; Nafz, B.; Persson, P.; Elsner, F.; Grosse-Siestrup, C.; Meissler, M.; Gutberlet, M.; Univ. Leipzig/ Leipzig Heart Center; Lengsfeld, P.; Voth, M.

    2011-01-01

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  18. Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging.

    Science.gov (United States)

    Shimizu, Kazuhiro; Kosaka, Nobuyuki; Fujiwara, Yasuhiro; Matsuda, Tsuyoshi; Yamamoto, Tatsuya; Tsuchida, Tatsuro; Tsuchiyama, Katsuki; Oyama, Nobuyuki; Kimura, Hirohiko

    2017-01-10

    The importance of arterial transit time (ATT) correction for arterial spin labeling MRI has been well debated in neuroimaging, but it has not been well evaluated in renal imaging. The purpose of this study was to evaluate the feasibility of pulsed continuous arterial spin labeling (pcASL) MRI with multiple post-labeling delay (PLD) acquisition for measuring ATT-corrected renal blood flow (ATC-RBF). A total of 14 volunteers were categorized into younger (n = 8; mean age, 27.0 years) and older groups (n = 6; 64.8 years). Images of pcASL were obtained at three different PLDs (0.5, 1.0, and 1.5 s), and ATC-RBF and ATT were calculated using a single-compartment model. To validate ATC-RBF, a comparative study of effective renal plasma flow (ERPF) measured by 99m Tc-MAG3 scintigraphy was performed. ATC-RBF was corrected by kidney volume (ATC-cRBF) for comparison with ERPF. The younger group showed significantly higher ATC-RBF (157.68 ± 38.37 mL/min/100 g) and shorter ATT (961.33 ± 260.87 ms) than the older group (117.42 ± 24.03 mL/min/100 g and 1227.94 ± 226.51 ms, respectively; P renal ASL-MRI as debated in brain imaging.

  19. Longitudinal fasting blood glucose patterns and arterial stiffness risk in a population without diabetes.

    Science.gov (United States)

    Wu, Yuntao; Yu, Junxing; Jin, Cheng; Li, Yun; Su, Jinmei; Wei, Guoqing; Zheng, Xiaoming; Gao, Jingsheng; Gao, Wenyuan; Wu, Shouling

    2017-01-01

    To identify long-term fasting blood glucose trajectories and to assess the association between the trajectories and the risk of arterial stiffness in individuals without diabetes. We enrolled 16,454 non-diabetic participants from Kailuan cohort. Fasting blood glucose concentrations were measured in 2006, 2008, and 2010 survey. Brachial-ankle pulse wave velocities were measured during 2011 to 2016. Multivariate regression model was used to estimate the difference of brachial-ankle pulse wave velocity levels and logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (95%CIs) of arterial stiffness risk, according to the fasting blood glucose trajectories. We identified five distinct fasting blood glucose trajectories and each of the trajectories was labeled according to its range and change over 2006-2010 survey: elevated-stable pattern (5.0% of participants), elevated-decreasing pattern (6.6%), moderate-increasing pattern (10.9%), moderate-stable pattern (59.3%), and low-stable pattern (18.2%). After adjustment for potential confounders, individuals with elevated-stable pattern had a 42.6 cm/s (95%CI: 24.7 to 60.6 cm/s) higher brachial-ankle pulse wave velocity level and a 37% (OR 1.37, 95%CI: 1.14 to 1.66) higher arterial stiffness risk, and individuals with moderate-increasing pattern had a 19.6 cm/s (95%CI: 6.9 to 32.3 cm/s) higher brachial-ankle pulse wave velocity level and a 17% (OR 1.17, 95%CI: 1.03 to 1.33) higher arterial stiffness risk, related to individuals with moderate-stable pattern. We did not find significant associations of the elevated-decreasing or low-stable patterns with arterial stiffness. Consistently, the cumulative average, variability, and increased rate of fasting blood glucose during 2006-2010 survey were significantly associated with the arterial stiffness risk. Discrete fasting blood glucose trajectories were associated with the arterial stiffness risk in non-diabetic individuals.

  20. The effect of ultrasound on arterial blood flow: 1. Steady fully developed flow

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1990-12-01

    The paper models the effects of ultrasound heating of the tissues and the resultant perturbation on blood flow in the arteries and veins. It is assumed that the blood vessel is rigid and the undisturbed flow is fully developed. Acoustical perturbation on this Poiseuille flow, for the general three-dimensional flow with heat transfer in an infinitely long pipe is considered. Closed form analytical solutions are obtained to the problem. It is discovered that the effects of the ultrasound heating are concentrated at the walls of the blood vessels. (author). 4 refs

  1. Unsteady Blood Flow with Nanoparticles Through Stenosed Arteries in the Presence of Periodic Body Acceleration

    Science.gov (United States)

    Fatin Jamil, Dzuliana; Roslan, Rozaini; Abdulhameed, Mohammed; Che-Him, Norziha; Sufahani, Suliadi; Mohamad, Mahathir; Ghazali Kamardan, Muhamad

    2018-04-01

    The effects of nanoparticles such as Fe 3O4,TiO2, and Cu on blood flow inside a stenosed artery are studied. In this study, blood was modelled as non-Newtonian Bingham plastic fluid subjected to periodic body acceleration and slip velocity. The flow governing equations were solved analytically by using the perturbation method. By using the numerical approaches, the physiological parameters were analyzed, and the blood flow velocity distributions were generated graphically and discussed. From the flow results, the flow speed increases as slip velocity increases and decreases as the values of yield stress increases.

  2. Reducing blood loss during laparoscopic myomectomy by temporary uterine artery clamping using bulldog clamp

    Directory of Open Access Journals (Sweden)

    Kai-Jo Chiang

    2014-01-01

    Full Text Available Uterine myoma is the most common benign gynecologic tumor worldwide. Mini-invasive surgery has become popular for myomectomy, with advantages over laparotomy. However, reducing blood loss during laparoscopic myomectomy is a major concern for the surgeon because of the limitation in making a quick control bleeding during the operation. Several methods have proved to decrease blood flow, but are not always effective or available. We present a case of uterine myoma with the uterine arteries clamped by bulldog clamps during laparoscopic myomectomy. The myoma was removed successfully with minimal blood loss (<50 ml during the operation. This is an effective, safe, and reliable method for reducing bleeding during laparoscopic myomectomy that does not require ligation of the uterine artery.

  3. Quantification of multiple elements in dried blood spot samples

    DEFF Research Database (Denmark)

    Pedersen, Lise; Andersen-Ranberg, Karen; Hollergaard, Mads

    2017-01-01

    BACKGROUND: Dried blood spots (DBS) is a unique matrix that offers advantages compared to conventional blood collection making it increasingly popular in large population studies. We here describe development and validation of a method to determine multiple elements in DBS. METHODS: Elements were...... in venous blood. Samples with different hematocrit were spotted onto filter paper to assess hematocrit effect. RESULTS: The established method was precise and accurate for measurement of most elements in DBS. There was a significant but relatively weak correlation between measurement of the elements Mg, K...

  4. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  5. Estimation of arterial arrival time and cerebral blood flow from QUASAR arterial spin labeling using stable spline.

    Science.gov (United States)

    Castellaro, Marco; Peruzzo, Denis; Mehndiratta, Amit; Pillonetto, Gianluigi; Petersen, Esben Thade; Golay, Xavier; Chappell, Michael A; Bertoldo, Alessandra

    2015-12-01

    QUASAR arterial spin labeling (ASL) permits the application of deconvolution approaches for the absolute quantification of cerebral perfusion. Currently, oscillation index regularized singular value decomposition (oSVD) combined with edge-detection (ED) is the most commonly used method. Its major drawbacks are nonphysiological oscillations in the impulse response function and underestimation of perfusion. The aim of this work is to introduce a novel method to overcome these limitations. A system identification method, stable spline (SS), was extended to address ASL peculiarities such as the delay in arrival of the arterial blood in the tissue. The proposed framework was compared with oSVD + ED in both simulated and real data. SS was used to investigate the validity of using a voxel-wise tissue T1 value instead of using a single global value (of blood T1 ). SS outperformed oSVD + ED in 79.9% of simulations. When applied to real data, SS exhibited a physiologically realistic range for perfusion and a higher mean value with respect to oSVD + ED (55.5 ± 9.5 SS, 34.9 ± 5.2 oSVD + ED mL/100 g/min). SS can represent an alternative to oSVD + ED for the quantification of QUASAR ASL data. Analysis of the retrieved impulse response function revealed that using a voxel wise tissue T1 might be suboptimal. © 2014 Wiley Periodicals, Inc.

  6. Elevated arterial blood pressure after superior cavo-pulmonary anastomosis is associated with elevated pulmonary artery pressure and cerebrovascular dysautoregulation.

    Science.gov (United States)

    Cabrera, Antonio G; Kibler, Kathleen K; Blaine Easley, R; Goldsworthy, Michelle; Shekerdemian, Lara S; Andropoulos, Dean B; Heinle, Jeffrey; Gottlieb, Erin A; Vu, Eric; Brady, Ken M

    2018-04-18

    BackgroundElevated arterial blood pressure (ABP) is common after superior bidirectional cavopulmonary anastomosis (BCPA). The effects of elevated ABP after BCPA on cerebrovascular hemodynamics are unknown. We sought to determine the relationship between elevated ABP and cerebrovascular autoregulation after BCPA.MethodsProspective, observational study on infants with single-ventricle physiology after BCPA surgery. Continuous recordings of mean ABP, mean cavopulmonary artery pressure (PAP), near-infrared spectroscopy measures of cerebral oximetry (regional cerebral oxygen saturation (rSO 2 )), and relative cerebral blood volume index were obtained from admission to extubation. Autoregulation was measured as hemoglobin volume index (HVx). Physiologic variables, including the HVx, were tested for variance across ABP.ResultsSixteen subjects were included in the study. Elevated ABP post-BCPA was associated with both, elevated PAP (PABP and alterations in rSO 2 . Using piecewise regression, the relationship of PAP to ABP demonstrated a breakpoint at 68 mm Hg (interquartile range (IQR) 62-70 mm Hg). Curve fit of HVx as a function of ABP identified optimal ABP supporting robust autoregulation at a median ABP of 55 mm Hg (IQR 51-64 mm Hg).ConclusionsElevated ABP post-BCPA is associated with cerebrovascular dysautoregulation, and elevated PAP. The effects, of prolonged dysautoregulation within this population, require further study.Pediatric Research advance online publication, 18 April 2018; doi:10.1038/pr.2018.31.

  7. Extensive monitoring through multiple blood samples in professional soccer players.

    Science.gov (United States)

    Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter; Storskov, Anders; Kjær, Michael; Andersen, Jesper L

    2013-05-01

    The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players and to analyze different blood parameters in relation to seasonal changes in training and match exposure. Blood samples were collected 5 times during a 6-month period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, the players were tested for body composition, V[Combining Dot Above]O2max and physical performance by the Yo-Yo intermittent endurance submax test (IE2). Multiple variations in blood parameters occurred during the observation period, including a decrease in hemoglobin and an increase in hematocrit as the competitive season progressed. Iron and transferrin were stable, whereas ferritin showed a decrease at the end of the season. The immunoglobulin A (IgA) and IgM increased in the period with basal physical training and at the end of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. The V[Combining Dot Above]O2max decreased toward the end of the season, whereas no significant changes were observed in the IE2 test. The regular blood samples from elite soccer players reveal significant changes that may be related to changes in training pattern, match exposure, or length of the match season. Especially the end of the preparation season and at the end of the competitive season seem to be time points were the blood-derived values indicate that the players are under excessive physical strain and might be more subjected to a possible overreaching-overtraining conditions. We suggest that regular analyses of blood samples could be an important initiative to optimize training adaptation, training load, and game participation, but sampling has to be regular, and a database has to be built for each individual player.

  8. Twenty-four-hour exposure to altered blood flow modifies endothelial Ca2+-activated K+ channels in rat mesenteric arteries

    DEFF Research Database (Denmark)

    Hilgers, Rob H P; Janssen, Ger M J; Fazzi, Gregorio E

    2010-01-01

    We tested the hypothesis that changes in arterial blood flow modify the function of endothelial Ca2+-activated K+ channels [calcium-activated K+ channel (K(Ca)), small-conductance calcium-activated K+ channel (SK3), and intermediate calcium-activated K+ channel (IK1)] before arterial structural...... remodeling. In rats, mesenteric arteries were exposed to increased [+90%, high flow (HF)] or reduced blood flow [-90%, low flow (LF)] and analyzed 24 h later. There were no detectable changes in arterial structure or in expression level of endothelial nitric-oxide synthase, SK3, or IK1. Arterial relaxing...... arteries, the balance between the NO/prostanoid versus EDHF response was unaltered. However, the contribution of IK1 to the EDHF response was enhanced, as indicated by a larger effect of TRAM-34 and a larger residual NS309-induced relaxation in the presence of UCL 1684. Reduction of blood flow selectively...

  9. Distribution of the blood flow supplied by the vertebral artery in humans as assessed by emission CT

    International Nuclear Information System (INIS)

    Taki, W.; Handa, H.; Higa, T.; Tanada, S.; Fukuyama, H.; Fujita, T.; Yonekawa, Y.; Kameyama, M.; Torizuka, K.

    1984-01-01

    Though unilateral blood distribution of the vertebral artery has not been studied in humans, it is significant when considering the ischemic events especially embolic occlusion in vertebrobasilar system. To clarify the blood distribution, Krypton-81m was continuously infused into the vertebral arteries of 10 patients. Radioactivity was recorded by a rotating gamma camera. The perfusion images, reconstructed by computer in the transaxial plane, were classified according to whether the distribution was equal, or predominantly unilateral. Overlapping of blood supply from each vertebral artery was studied. In addition, the perfusion from one of the vertebral arteries revealed four distribution patterns with respect to laterality. A) ipsilateral; B) contralateral; C) bilateral; D) mosaic. Images obtained following perfusion of the vertebral artery show less uniformity compared to that of the internal carotid artery, suggesting a complicated vascular supply of the vertebral basilar territory. This complex distribution can be classified by the use of continuous infusion of Krypton-81m

  10. Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

    Science.gov (United States)

    Martin, Jeffrey S; Borges, Alexandra R; Christy, John B; Beck, Darren T

    2015-10-01

    Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.

  11. Comparison of arterial blood gas with continuous intra-arterial and transcutaneous PO2 sensors in adult critically ill patients.

    Science.gov (United States)

    Green, G E; Hassell, K T; Mahutte, C K

    1987-05-01

    We compared the partial pressure of oxygen directly via a continuous intra-arterial probe (PiaO2) and indirectly using a transcutaneous device (PtcO2) with simultaneously obtained arterial blood PaO2. The PiaO2 values were measured using a bipolar oxygen sensor placed through an 18-ga arterial catheter. The PtcO2 values were measured using a transcutaneous O2-CO2 sensor placed on the abdomen. Seven critically ill, hemodynamically stable, ventilator-dependent adult patients were studied. Measurements were obtained at varying concentrations (0.25 to 1.0) of inspired oxygen after a 10-min stabilization. A total of 78 simultaneous values were obtained; by linear regression: PiaO2 = 0.91 PaO2 + 1.39 (r = .98, standard errors of the estimate [SEE] = 18.6); PtcO2 = 0.39 PaO2 + 36.2 (r = .89, SEE = 14.1). To assess these instruments as trend monitors, we compared the changes in simultaneous PaO2, PiaO2, and PtcO2 values; by linear regression: delta PiaO2 = 0.90 delta PaO2 + 3.88 (r = .96, SEE = 27.7); delta PtcO2 = 0.43 delta PaO2 + 5.6 (r = .94, SEE = 15.2). We conclude that, although these instruments correlate highly with the PaO2, the SEE was substantial and therefore may limit their clinical reliability in adults. Any acute or clinically significant change in PiaO2 or PtcO2 should be confirmed with a blood gas PaO2.

  12. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.

  13. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  14. Energy harvesting from arterial blood pressure for powering embedded brain sensors

    Science.gov (United States)

    Nanda, Aditya; Karami, M. Amin

    2016-04-01

    This paper investigates energy harvesting from arterial blood pressure via the piezoelectric effect by using a novel streaked cylinder geometry for the purpose of powering embedded micro-sensors in the brain. Initially, we look at the energy harvested by a piezoelectric cylinder placed inside an artery acted upon by blood pressure. Such an arrangement would be tantamount to constructing a stent out of piezoelectric materials. A stent is a cylinder placed in veins and arteries to prevent obstruction in blood flow. The governing equations of a conductor coated piezoelectric cylinder are obtained using Hamilton's principle. Pressure acting in arteries is radially directed and this is used to simplify the modal analysis and obtain the transfer function relating pressure to the induced voltage across the surface of the harvester. The power harvested by the cylindrical harvester is obtained for different shunt resistances. Radially directed pressure occurs elsewhere and we also look at harvesting energy from oil flow in pipelines. Although the energy harvested by the cylindrical energy harvester is significant at resonance, the natural frequency of the system is found to be very high. To decrease the natural frequency, we propose a novel streaked stent design by cutting it along the length, transforming it to a curved plate and decreasing the natural frequency. The governing equations corresponding to the new geometry are derived using Hamilton's principle and modal analysis is used to obtain the transfer function.

  15. Dynamic 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography of liver tumours without blood sampling

    DEFF Research Database (Denmark)

    Keiding, S; Munk, O L; Schiøtt, K M

    2000-01-01

    Positron emission tomography (PET) using 2-[18F]fluoro-2-deoxy-D-glucose (FDG) is a useful diagnostic tool for the detection of tumours. Using dynamic FDG PET, net metabolic clearance of FDG, K, can be calculated by Gjedde-Patlak analysis of the time course of the radioactivity concentrations...... in tissue and arterial blood. We examined whether time-activity curves (TACs) based on arterial blood sampling could be replaced by TACs obtained from the descending aorta in dynamic PET scans of patients with liver tumours. The study was performed in two parts, using data from dynamic liver scans......, and 2.1-8.4:1 (mean, 4.6:1) based on blood sample TACs (P>0.3). We conclude that arterial blood sampling can be replaced by the present AORTA-VOI in the calculation of the net metabolic clearance of FDG in dynamic PET studies of liver tumours in human subjects. Udgivelsesdato: 2000-Apr...

  16. Can flavonoid-rich chocolate modulate arterial elasticity and pathological uterine artery Doppler blood flow in pregnant women? A pilot study.

    Science.gov (United States)

    von Wowern, Emma; Olofsson, Per

    2018-09-01

    Dark chocolate has shown beneficial effects on cardiovascular health and might also modulate hypertensive complications in pregnancy and uteroplacental blood flow. Increased uteroplacental resistance is associated with systemic arterial stiffness. We aimed to investigate the short-term effect of flavonoid-rich chocolate on arterial stiffness and Doppler blood flow velocimetry indexes in pregnant women with compromised uteroplacental blood flow. Doppler blood flow velocimetry and digital pulse wave analysis (DPA) were performed in 25 women pregnant in the second and third trimesters with uterine artery (UtA) score (UAS) 3-4, before and after 3 days of ingestion of chocolate with high flavonoid and antioxidant contents. UtA pulsatility index (PI), UtA diastolic notching, UAS (semiquantitative measure of PI and notching combined), and umbilical artery PI were calculated, and DPA variables representing central and peripheral maternal arteries were recorded. Mean UtA PI (p = .049) and UAS (p = .025) significantly decreased after chocolate consumption. There were no significant changes in UtA diastolic notching or any DPA indexes of arterial stiffness/vascular tone. Chocolate may have beneficial effects on the uteroplacental circulation, but in this pilot study, we could not demonstrate effects on arterial vascular tone as assessed by DPA.

  17. Investigation Of Arterial Blood Pressure Level And Metabolic Indices In Patients With Arterial Hypertension At Pharmacotherapy With Antihypertensive Medicines Of Various Chemical Structure

    Directory of Open Access Journals (Sweden)

    G.Kh. Glybochko

    2009-12-01

    Full Text Available The research goal is to carry on the comparative analysis of medicines of various chemical structure, Telmisar-tan and Bisoprolol, and to reveal their effect on the arterial blood pressure level and the indices of various metabolic processes in patients with arterial hypertension. 60 out-patients with arterial hypertension (stage II risk III both males and females aged 33-55 have been under study taking Telmisartan and Bisoprolol for 3 months. While treating the patients the arterial blood pressure level control and biochemical investigations for determination the indices of metabolic processes have been carried out. The investigated medications have provided the decrease of systolic and diastolic arterial pressure parameters, the increase of concentration of total and ionized calcium, chlorine ions, urea and total bilirubin in blood plasma. Therapy with Telmisartan has shown more significant increase of potassium level in erythro-cytes, decrease of levels of natrium, glucose, glycolized hemoglobin and triglycerides and increased contents of alani-naminotransferase and aspartataminotransferase. The course of therapy with Bisoprolol has restored the normal level of magnesium in blood plasma, has not have any influence on carbohydrate and lipid metabolism, increased the level of alaninaminotransferase and significantly increased the contents of total and ionized calcium, urea and creatinine. 3-months therapy with Telmisartan and Bisoprolol has proved the decrease of systolic and diastolic arterial pressure in patients with arterial hypertension. The medications under study have had active and variable effects on metabolic indices

  18. The effects of fenoldopam on coronary conduit blood flow after coronary artery bypass graft surgery.

    LENUS (Irish Health Repository)

    Halpenny, M

    2012-02-03

    OBJECTIVE: To quantify the effects of fenoldopam, 0.1 microg\\/kg\\/min, on left internal mammary artery (LIMA) and saphenous vein blood flow after coronary anastomosis. DESIGN: Prospective, randomized, double-blind, placebo-controlled trial. SETTING: University teaching hospital, single institution. PARTICIPANTS: Thirty-one American Society of Anesthesiologists III patients undergoing elective coronary revascularization. INTERVENTIONS: A perivascular ultrasonic flow probe (Linton Instrumentation, Norfolk, UK) was placed around the LIMA and saphenous vein graft after coronary anastomosis. MEASUREMENTS AND MAIN RESULTS: Immediately before and at 5-minute intervals for 15 minutes after starting the infusion, blood flow was measured in the LIMA and one saphenous vein graft using a transit time ultrasonic flow probe. Heart rate, blood pressure, and central venous pressure were documented at these time points. Administration of fenoldopam, 0.1 microg\\/kg\\/min, did not alter heart rate or blood pressure. A small, nonsignificant increase in LIMA blood flow occurred during the 15-minute study period (30 +\\/- 12 to 35 +\\/- 10 mL\\/min) in patients who received fenoldopam. No significant changes occurred in the placebo group. CONCLUSIONS: The findings indicate that fenoldopam, 0.1 microg\\/kg\\/min, did not influence coronary conduit blood flow to a clinically significant extent. The small increase in LIMA blood flow may be of greater importance in high-risk patients or in the prevention of coronary arterial spasm.

  19. The genetic basis for altered blood vessel function in disease: large artery stiffening

    Directory of Open Access Journals (Sweden)

    Alex Agrotis

    2005-12-01

    Full Text Available Alex AgrotisThe Cell Biology Laboratory, Baker Heart Research Institute, Melbourne, Victoria, AustraliaAbstract: The progressive stiffening of the large arteries in humans that occurs during aging constitutes a potential risk factor for increased cardiovascular morbidity and mortality, and is accompanied by an elevation in systolic blood pressure and pulse pressure. While the underlying basis for these changes remains to be fully elucidated, factors that are able to influence the structure and composition of the extracellular matrix and the way it interacts with arterial smooth muscle cells could profoundly affect the properties of the large arteries. Thus, while age and sex represent important factors contributing to large artery stiffening, the variation in growth-stimulating factors and those that modulate extracellular production and homeostasis are also being increasingly recognized to play a key role in the process. Therefore, elucidating the contribution that genetic variation makes to large artery stiffening could ultimately provide the basis for clinical strategies designed to regulate the process for therapeutic benefit.Keywords: arterial stiffness, genes, polymorphism, extracellular matrix proteins

  20. Automated blood-sample handling in the clinical laboratory.

    Science.gov (United States)

    Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O

    1990-09-01

    The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.

  1. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  2. Some problems of treating acute arterial obstruction using hyperbaric oxygenation ultraviolet irradiation of blood and hemosorption

    International Nuclear Information System (INIS)

    Karyakin, A.M.

    1988-01-01

    Up-to-date state of the problem of acute arterial obstruction (AAO) is considered and clinical observations of patients with acute emboli and thrombosis of abdominal aorta and main arteries of lower extremitics are analyzed. Complex of detoxication therapy and measures on controlling AAO in patients during postoperation period is presented. Complex application of hemosorption, ultraviolet irradiation of autoblood and hyperbaric oxygenation enabled to achieve correction of some indices. Reliable evidences of high therapeutic efficiency of combined application of mentioned methods to patients with reconstructed blood flow are presented. 38 refs.; 3 tabs

  3. Magnetization Transfer Effects on the Efficiency of Flow-driven Adiabatic Fast Passage Inversion of Arterial Blood

    OpenAIRE

    Hernandez-Garcia, Luis; Lewis, David P.; Moffat, Bradford; Branch, Craig A.

    2007-01-01

    Continuous arterial spin labeling experiments typically use flow-driven adiabatic fast passage (AFP) inversion of the arterial blood water protons. In this article, we measure the effect of magnetization transfer in blood and how it affects the inversion label. We use modified Bloch equations to model flow-driven adiabatic inversion in the presence of magnetization transfer in blood flowing at velocities from 1 to 30 cm/s in order to explain our findings. Magnetization transfer results in a r...

  4. Non-dipping blood pressure patterns and arterial stiffness parameters in patients with Behcet's disease.

    Science.gov (United States)

    Celik, Gulperi; Yilmaz, Sema; Ergulu Esmen, Serpil

    2015-12-01

    Behcet's disease is a multisystemic vasculitis involving veins and arteries of various sizes. Non-dipping status, augmentation index and pulse wave velocity are important determinants of cardiovascular mortality and morbidity. We investigated the non-dipping status and arterial stiffness in patients with Behcet's disease. In this cross-sectional study, we examined the vascular parameters of 96 patients with Behcet's disease (53% female) and 60 age- and sex-matched control subjects. The non-dipping status and arterial distensibility were assessed using a Mobil-O-Graph Arteriograph, an automatic oscillometric device. In total, 65.6% of 96 patients were systolic non-dippers, and 34.4% exhibited high augmentation indices. Ten percent of the control subjects were systolic non-dippers, and 11.7% exhibited high augmentation indices. Nocturnal decreases in systolic blood pressure correlated with central systolic blood pressure and diastolic blood pressure, as well as nocturnal decreases in diastolic blood pressure. Furthermore, non-dipper patients with Behcet's disease exhibited higher nocturnal cardiac outputs than did dipper patients with Behcet's disease. Augmentation index correlated negatively with C-reactive protein and correlated positively with both 24 h and nocturnal peripheral resistance, as well as 24 h pulse wave velocity. The patients with high augmentation indices exhibited lower creatinine clearance, as well as lower nocturnal cardiac outputs, higher 24 h peripheral resistance and higher 24 h pulse wave velocities. Non-dipping status and arterial stiffness may exacerbate the harmful cardiovascular effects of the other. In addition to conventional risk factors, non-dipping status and arterial stiffness should be examined during the follow-up evaluations of patients with Behcet's disease.

  5. Adaptive control of theophylline therapy: importance of blood sampling times.

    Science.gov (United States)

    D'Argenio, D Z; Khakmahd, K

    1983-10-01

    A two-observation protocol for estimating theophylline clearance during a constant-rate intravenous infusion is used to examine the importance of blood sampling schedules with regard to the information content of resulting concentration data. Guided by a theory for calculating maximally informative sample times, population simulations are used to assess the effect of specific sampling times on the precision of resulting clearance estimates and subsequent predictions of theophylline plasma concentrations. The simulations incorporated noise terms for intersubject variability, dosing errors, sample collection errors, and assay error. Clearance was estimated using Chiou's method, least squares, and a Bayesian estimation procedure. The results of these simulations suggest that clinically significant estimation and prediction errors may result when using the above two-point protocol for estimating theophylline clearance if the time separating the two blood samples is less than one population mean elimination half-life.

  6. Non-terminal blood sampling techniques in Guinea pigs

    DEFF Research Database (Denmark)

    Birck, Malene Muusfeldt; Tveden-Nyborg, Pernille; Lindblad, Maiken Marie

    2014-01-01

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features...... of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require...... repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e...

  7. Uso de sangue arterial e venoso no exame do equilíbrio ácido-básico de novilhos normais ou com acidose metabólica Arterial and venous blood in the assessment of blood gas and acid-base status in healthy steers or steers with metabolic acidosis

    Directory of Open Access Journals (Sweden)

    Maria Claudia Araripe Sucupira

    2003-10-01

    were continuously sampled for 11 fortnights. At the end of the experiment steers from groups 2 and principally 3 presented a moderate level of metabolic acidosis. Higher pH and pO2 levels were found in arterial blood; conversely, higher level of bicarbonate, TCO2, BE and pO2 levels were found in the venous blood. High correlation was found in the pH (r = 0.81, bicarbonate and TCO2 (r = 0.94 between venous and arterial blood; median correlation but significant in the pCO2 (r = 0.56 and lack of correlation in the pO2 (r = -0.06. The higher the pCO2, the higher the bicarbonate (r = 0.54 and TCO2 (r = 0.56 concentration. In spite of the small differences of pH, bicarbonate, TCO2 and even pCO2 between venous and arterial blood the values of arterial blood can be predicted adequately from the venous blood either in healthy steers or steers with moderate metabolic acidosis. When respiratory changes are concerned arterial blood must be collected for evaluating pO2. It was easier to sample venous blood than arterial blood.

  8. Arterial blood supply to midbrain, thalamus and internal capsule on CT, 3

    International Nuclear Information System (INIS)

    Takeshita, Gen; Ottomo, Michinori; Sasaki, Taisuke; Fukuda, Eiko.

    1984-01-01

    The selective injection of dye into the anterior choroidal artery (blue), the medial posterior choroidal artery (green), and the lateral posterior choroidal artery (red), using seven post-mortem brains, was performed. After fixation, sections parallel with the orbito-meatal line were obtained. The distribution of the anterior choroidal artery was visualized in the uncal region of the temporal lobe and the cerebral peduncle below the slice of the third ventricle. On the slice of the third ventricle, the lateral part of the geniculate region, the globus pallidus, and the posterior limb of the internal capsule were supplied by the anterior choroidal artery. The blood supply of the posterior limb of the internal capsule was also demonstrated on the slice of the anterior horn and on the body of the lateral ventricle. The distribution of the medial posterior choroidal artery was visualized in the tegmentum of the midbrain below the slice of the third ventricle, and on the slice of the anterior horn, the pineal body and the posterior part of the thalamus were also supplied. The distribution of the lateral posterior choroidal artery was visualized in the lateral part of the midbrain, around the red nucleus, below the slice of the third ventricle, and on the slice of the third ventricle, the upper part of the cerebral peduncle, the posterior part of the hypothalamus, and the medial part of the geniculate region were also supplied. Also, distribution to the medial and posterior parts of the thalamus was noted on the slice of the anterior horn. It was quite useful to identify the distribution of each choroidal artery on CT sections for the CT diagnosis of cerebrovascular disorders. (author)

  9. Conventional blood conservation techniques in 500 consecutive coronary artery bypass operations.

    Science.gov (United States)

    Ovrum, E; Holen, E A; Abdelnoor, M; Oystese, R

    1991-09-01

    With use of a nonpharmacological, simple, and inexpensive program for blood conservation, 500 consecutive patients underwent elective coronary artery bypass grafting without need of homologous red cell transfusions in 493 (98.6%). At least one internal mammary artery was grafted in all but 1 patient, with supplemental saphenous vein grafts. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of extracorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard-shell cardiotomy reservoir from the heart-lung machine, autotransfusion of the shed mediastinal blood was continued hourly up to 18 hours after operation. The mean postoperative mediastinal blood loss was 643 +/- 354 mL, whereas 624 +/- 296 mL was autotransfused. Thirteen patients (2.6%) needed reexploration for bleeding, of whom 7 (7/500, 1.4%) received homologous blood. No other patients required red cell transfusions. In addition, 9 patients were given a mean of 2.6 units of fresh frozen plasma because of suspected coagulopathy. No platelets were transfused, and no cryoprecipitate therapy was undertaken. Thus, in total, 484 patients (96.8%) were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 121 +/- 14 g/L (12.1 +/- 1.4 g/dL) and the hematocrit, 0.36 +/- 0.04. Postoperative complications were few. There was one in-hospital death (0.2%).

  10. Investigation of spiral blood flow in a model of arterial stenosis.

    Science.gov (United States)

    Paul, Manosh C; Larman, Arkaitz

    2009-11-01

    The spiral component of blood flow has both beneficial and detrimental effects in human circulatory system [Stonebridge PA, Brophy CM. Spiral laminar flow in arteries? Lancet 1991; 338: 1360-1]. We investigate the effects of the spiral blood flow in a model of three-dimensional arterial stenosis with a 75% cross-sectional area reduction at the centre by means of computational fluid dynamics (CFD) techniques. The standard k-omega model is employed for simulation of the blood flow for the Reynolds number of 500 and 1000. We find that for Re=500 the spiral component of the blood flow increases both the total pressure and velocity of the blood, and some significant differences are found between the wall shear stresses of the spiral and non-spiral induced flow downstream of the stenosis. The turbulent kinetic energy is reduced by the spiral flow as it induces the rotational stabilities in the forward flow. For Re=1000 the tangential component of the blood velocity is most influenced by the spiral speed, but the effect of the spiral flow on the centreline turbulent kinetic energy and shear stress is mild. The results of the effects of the spiral flow are discussed in the paper along with the relevant pathological issues.

  11. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  12. The mechanical properties of the systemic and pulmonary arteries of Python regius correlate with blood pressures.

    Science.gov (United States)

    van Soldt, Benjamin J; Danielsen, Carl Christian; Wang, Tobias

    2015-12-01

    Pythons are unique amongst snakes in having different pressures in the aortas and pulmonary arteries because of intraventricular pressure separation. In this study, we investigate whether this correlates with different blood vessel strength in the ball python Python regius. We excised segments from the left, right, and dorsal aortas, and from the two pulmonary arteries. These were subjected to tensile testing. We show that the aortic vessel wall is significantly stronger than the pulmonary artery wall in P. regius. Gross morphological characteristics (vessel wall thickness and correlated absolute amount of collagen content) are likely the most influential factors. Collagen fiber thickness and orientation are likely to have an effect, though the effect of collagen fiber type and cross-links between fibers will need further study. © 2015 Wiley Periodicals, Inc.

  13. Increasing arterial blood pressure with norepinephrine does not improve microcirculatory blood flow: a prospective study

    NARCIS (Netherlands)

    Dubin, Arnaldo; Pozo, Mario O.; Casabella, Christian A.; Palizas, Fernando; Murias, Gaston; Moseinco, Miriam C.; Kanoore Edul, Vanina S.; Estenssoro, Elisa; Ince, Can

    2009-01-01

    Introduction Our goal was to assess the effects of titration of a norepinephrine infusion to increasing levels of mean arterial pressure (MAP) on sublingual microcirculation. Methods Twenty septic shock patients were prospectively studied in two teaching intensive care units. The patients were

  14. An effective fractal-tree closure model for simulating blood flow in large arterial networks.

    Science.gov (United States)

    Perdikaris, Paris; Grinberg, Leopold; Karniadakis, George Em

    2015-06-01

    The aim of the present work is to address the closure problem for hemodynamic simulations by developing a flexible and effective model that accurately distributes flow in the downstream vasculature and can stably provide a physiological pressure outflow boundary condition. To achieve this goal, we model blood flow in the sub-pixel vasculature by using a non-linear 1D model in self-similar networks of compliant arteries that mimic the structure and hierarchy of vessels in the meso-vascular regime (radii [Formula: see text]). We introduce a variable vessel length-to-radius ratio for small arteries and arterioles, while also addressing non-Newtonian blood rheology and arterial wall viscoelasticity effects in small arteries and arterioles. This methodology aims to overcome substantial cut-off radius sensitivities, typically arising in structured tree and linearized impedance models. The proposed model is not sensitive to outflow boundary conditions applied at the end points of the fractal network, and thus does not require calibration of resistance/capacitance parameters typically required for outflow conditions. The proposed model convergences to a periodic state in two cardiac cycles even when started from zero-flow initial conditions. The resulting fractal-trees typically consist of thousands to millions of arteries, posing the need for efficient parallel algorithms. To this end, we have scaled up a Discontinuous Galerkin solver that utilizes the MPI/OpenMP hybrid programming paradigm to thousands of computer cores, and can simulate blood flow in networks of millions of arterial segments at the rate of one cycle per 5 min. The proposed model has been extensively tested on a large and complex cranial network with 50 parent, patient-specific arteries and 21 outlets to which fractal trees where attached, resulting to a network of up to 4,392,484 vessels in total, and a detailed network of the arm with 276 parent arteries and 103 outlets (a total of 702,188 vessels

  15. Evaluation of blood flow in Allograft Renal Arteries anastomosed with two different techniques

    International Nuclear Information System (INIS)

    Zomorrodi, A.; Bohluli, A.; Tarzamany, M.K.

    2008-01-01

    Renal artery stenosis in renal transplantation (TRAS) is an avoidable short or long term surgical complication. The etiology is multifactorial, but faulty anastomosis is a major factor. In our transplant center, we evaluated the incidence of TRAS with the use of two different suturing techniques of the anastomosis site between allograft renal and renal and iliac arteries in two groups of renal transplant recipients, group A: 14 patients (6 males and 8 females with age 16 to 59 and mean age of 38 years) in whom allograft arteries were anastomosed with a continuous suture technique and group B: 14 patients (7 males and 7 females with age 32 to 61 and mean age of 46.6 years) in whom the allograft arteries were anastomosed with a combined suture technique (continuous and uninterrupted. Post transplantation, the velocity of blood flow in the renal and iliac arteries at the site of anastomosis was measured by color Doppler ultrasound. The ultrasonographer was blinded to the surgical technique in both study groups. The ratio of the maximum velocity of blood at the site of anastomosis to that in the iliac artery of less than 2.5 was considered as non-significant stenosis, while a ratio of more than 2.5 was considered significant stenosis. In group A there were 9 cases of non-significant stenosis in comparison to 3 cases in group B, while there were no cases of significant stenosis in group A in comparison to 3 cases in group B; the difference was not statistically significant. We conclude that there was no difference in the compared surgical techniques of anastomosis in our study groups. This suggests that other factors such as gentle handling of tissue, enough spatula, margin reversion and comparable diameter of the anastomosed vessels may be more important in the prevention of renal allograft stenosis than the type of suture technique. (author)

  16. Improved sample capsule for determination of oxygen in hemolyzed blood

    Science.gov (United States)

    Malik, W. M.

    1967-01-01

    Sample capsule for determination of oxygen in hemolyzed blood consists of a measured section of polytetrafluoroethylene tubing equipped at each end with a connector and a stopcock valve. This method eliminates errors from air entrainment or from the use of mercury or syringe lubricant.

  17. C1-esterase inhibitor protects against early vein graft remodeling under arterial blood pressure.

    Science.gov (United States)

    Krijnen, Paul A J; Kupreishvili, Koba; de Vries, Margreet R; Schepers, Abbey; Stooker, Wim; Vonk, Alexander B A; Eijsman, Leon; Van Hinsbergh, Victor W M; Zeerleder, Sacha; Wouters, Diana; van Ham, Marieke; Quax, Paul H A; Niessen, Hans W M

    2012-01-01

    Arterial pressure induced vein graft injury can result in endothelial loss, accelerated atherosclerosis and vein graft failure. Inflammation, including complement activation, is assumed to play a pivotal role herein. Here, we analyzed the effects of C1-esterase inhibitor (C1inh) on early vein graft remodeling. Human saphenous vein graft segments (n=8) were perfused in vitro with autologous blood either supplemented or not with purified human C1inh at arterial pressure for 6h. The vein segments and perfusion blood were analyzed for cell damage and complement activation. In addition, the effect of purified C1inh on vein graft remodeling was analyzed in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. Application of C1inh in the in vitro perfusion model resulted in significantly higher blood levels and significantly more depositions of C1inh in the vein wall. This coincided with a significant reduction in endothelial loss and deposition of C3d and C4d in the vein wall, especially in the circular layer, compared to vein segments perfused without supplemented C1inh. Administration of purified C1inh significantly inhibited vein graft intimal thickening in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. C1inh significantly protects against early vein graft remodeling, including loss of endothelium and intimal thickening. These data suggest that it may be worth considering its use in patients undergoing coronary artery bypass grafting. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  18. Does mean arterial blood pressure scale with body mass in mammals?

    DEFF Research Database (Denmark)

    Poulsen, C B; Wang, T; Assersen, K

    2018-01-01

    For at least the last 30 years, it has been discussed whether mean arterial blood pressure (MAP) is independent of body mass or whether it increases in accordance with the vertical height between the heart and the brain. The debate has centred on the most appropriate mathematical models for analy......For at least the last 30 years, it has been discussed whether mean arterial blood pressure (MAP) is independent of body mass or whether it increases in accordance with the vertical height between the heart and the brain. The debate has centred on the most appropriate mathematical models......-Altman analysis showed a bias of 1 mm Hg with 95% confidence interval (from -35 to 36 mm Hg); that is, the limits of agreement between radiotelemetric studies and studies in restrained animals were double the supposed difference in the MAP between the mouse and elephant. In conclusion, the existing literature...

  19. Impact on early and late mortality after blood transfusion in coronary artery bypass graft surgery.

    Science.gov (United States)

    Santos, Antonio Alceu dos; Sousa, Alexandre Gonçalves; Thomé, Hugo Oliveira de Souza; Machado, Roberta Longo; Piotto, Raquel Ferrari

    2013-03-01

    To assess the 30-day and 1-year mortality associated to the red blood cell transfusion after coronary artery bypass grafting surgery. This procedure has been questioned by the international medical community, but it is still widely used in cardiac surgery. Therefore, it is needed more evidence of this medical practice in our country. We retrospectively analyzed 3,004 patients who underwent coronary artery bypass grafting surgery between June 2009 and July 2010. Patients were divided into two groups: non-transfused and transfused. The transfused group totaled 1,888 (63%) and non-transfused 1,116 (37%). There were 129 deaths in 30 days, with 108 (84%) in the transfused group and 21 (16%) in the non-transfused (Pconservation strategies should be encouraged to reduce blood products transfusions.

  20. Effect of tubing length on the dispersion correction of an arterially sampled input function for kinetic modeling in PET.

    Science.gov (United States)

    O'Doherty, Jim; Chilcott, Anna; Dunn, Joel

    2015-11-01

    Arterial sampling with dispersion correction is routinely performed for kinetic analysis of PET studies. Because of the the advent of PET-MRI systems, non-MR safe instrumentation will be required to be kept outside the scan room, which requires the length of the tubing between the patient and detector to increase, thus worsening the effects of dispersion. We examined the effects of dispersion in idealized radioactive blood studies using various lengths of tubing (1.5, 3, and 4.5 m) and applied a well-known transmission-dispersion model to attempt to correct the resulting traces. A simulation study was also carried out to examine noise characteristics of the model. The model was applied to patient traces using a 1.5 m acquisition tubing and extended to its use at 3 m. Satisfactory dispersion correction of the blood traces was achieved in the 1.5 m line. Predictions on the basis of experimental measurements, numerical simulations and noise analysis of resulting traces show that corrections of blood data can also be achieved using the 3 m tubing. The effects of dispersion could not be corrected for the 4.5 m line by the selected transmission-dispersion model. On the basis of our setup, correction of dispersion in arterial sampling tubing up to 3 m by the transmission-dispersion model can be performed. The model could not dispersion correct data acquired using a 4.5 m arterial tubing.

  1. Whole blood solubilization and discoloration before LSC of yttrium samples

    International Nuclear Information System (INIS)

    Lima, Marina F.; Leonardo, Lucio

    2009-01-01

    Liquid scintillation counting of whole blood and animal tissues samples could be severely impaired owing to quenching by their compounds. The objective of this previous study is preparing one protocol of 90 Y measurement to apply in biodistribution and dosimetry studies of radiopharmaceuticals labeled with this isotope and other beta emitters in in vivo and ex vivo samples. The first parameters considered to choose a method were: the largest blood sample per collection (80μl-90μl), attending the collection limit of less than 7.5% of total circulating blood volume for in vivo samples. Other parameters were the use of EDTA and cyclohexydine as solubilization and lytic agents, HNO 3 and H 2 O 2 as mineralizing agents and NH 4 OH as neutralization agent. One samples batch was tested in a water bath under the lower temperature to prevent the volume lose of the ionic phase. Other samples batch was mineralized over a hot-plate at 120 deg C following the currently largest sample amounts processing procedure in our laboratory by using HNO 3 and H 2 O 2 . Results show the contribution of the blood fragments as quenching in the region A ( 3 and/or NH 4 OH in the hot-plate digestion. As expected, the measurements in the three spectral regions show the proteins and colored fragments were completely removed by the hot-plate digestion. The rate between efficiency and 90 Sr- 90 Y concentration had not significant differences in the range between 120 Bq and 1200 Bq. (author)

  2. Automated artery-venous classification of retinal blood vessels based on structural mapping method

    Science.gov (United States)

    Joshi, Vinayak S.; Garvin, Mona K.; Reinhardt, Joseph M.; Abramoff, Michael D.

    2012-03-01

    Retinal blood vessels show morphologic modifications in response to various retinopathies. However, the specific responses exhibited by arteries and veins may provide a precise diagnostic information, i.e., a diabetic retinopathy may be detected more accurately with the venous dilatation instead of average vessel dilatation. In order to analyze the vessel type specific morphologic modifications, the classification of a vessel network into arteries and veins is required. We previously described a method for identification and separation of retinal vessel trees; i.e. structural mapping. Therefore, we propose the artery-venous classification based on structural mapping and identification of color properties prominent to the vessel types. The mean and standard deviation of each of green channel intensity and hue channel intensity are analyzed in a region of interest around each centerline pixel of a vessel. Using the vector of color properties extracted from each centerline pixel, it is classified into one of the two clusters (artery and vein), obtained by the fuzzy-C-means clustering. According to the proportion of clustered centerline pixels in a particular vessel, and utilizing the artery-venous crossing property of retinal vessels, each vessel is assigned a label of an artery or a vein. The classification results are compared with the manually annotated ground truth (gold standard). We applied the proposed method to a dataset of 15 retinal color fundus images resulting in an accuracy of 88.28% correctly classified vessel pixels. The automated classification results match well with the gold standard suggesting its potential in artery-venous classification and the respective morphology analysis.

  3. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring

    OpenAIRE

    Mark van Gastel; Sander Stuijk; Gerard de Haan

    2016-01-01

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO2) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted ...

  4. The gated blood pool scan in the evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Anger, K.; Erbel, R.; Krebs, W.; Meyer, J.; Moeller, T.; Schweizer, P.; Yalkinoglu, O.; Technische Hochschule Aachen

    1983-01-01

    38 patients with clinically suspected coronary artery disease were studied by contrast ventriculography, 2-dimensional echocardiography and multiple gated blood pool imaging (MUGA) without stress. The results were compared with eath other and with the final diagnosis confirmed by coronary angiography. The left ventricular ejection fraction is evaluated nearly identically and with sufficient accuracy by both non-invasive methods, local motion abnormalities are on the other hand diagnosed in the best way by MUGA imaging in our own cases. (orig.) [de

  5. Malaria PCR Detection in Cambodian Low-Transmission Settings: Dried Blood Spots versus Venous Blood Samples

    Science.gov (United States)

    Canier, Lydie; Khim, Nimol; Kim, Saorin; Eam, Rotha; Khean, Chanra; Loch, Kaknika; Ken, Malen; Pannus, Pieter; Bosman, Philippe; Stassijns, Jorgen; Nackers, Fabienne; Alipon, SweetC; Char, Meng Chuor; Chea, Nguon; Etienne, William; De Smet, Martin; Kindermans, Jean-Marie; Ménard, Didier

    2015-01-01

    In the context of malaria elimination, novel strategies for detecting very low malaria parasite densities in asymptomatic individuals are needed. One of the major limitations of the malaria parasite detection methods is the volume of blood samples being analyzed. The objective of the study was to compare the diagnostic accuracy of a malaria polymerase chain reaction assay, from dried blood spots (DBS, 5 μL) and different volumes of venous blood (50 μL, 200 μL, and 1 mL). The limit of detection of the polymerase chain reaction assay, using calibrated Plasmodium falciparum blood dilutions, showed that venous blood samples (50 μL, 200 μL, 1 mL) combined with Qiagen extraction methods gave a similar threshold of 100 parasites/mL, ∼100-fold lower than 5 μL DBS/Instagene method. On a set of 521 field samples, collected in two different transmission areas in northern Cambodia, no significant difference in the proportion of parasite carriers, regardless of the methods used was found. The 5 μL DBS method missed 27% of the samples detected by the 1 mL venous blood method, but most of the missed parasites carriers were infected by Plasmodium vivax (84%). The remaining missed P. falciparum parasite carriers (N = 3) were only detected in high-transmission areas. PMID:25561570

  6. The value of arterial blood gas parameters for prediction of mortality in survivors of out-of-hospital cardiac arrest

    Directory of Open Access Journals (Sweden)

    Katharina Isabel von Auenmueller

    2017-01-01

    Full Text Available Context: Sudden cardiac death is one of the leading causes of death in Europe, and early prognostication remains challenging. There is a lack of valid parameters for the prediction of survival after cardiac arrest. Aims: This study aims to investigate if arterial blood gas parameters correlate with mortality of patients after out-of-hospital cardiac arrest. Materials and Methods: All patients who were admitted to our hospital after resuscitation following out-of-hospital cardiac arrest between January 1, 2008, and December 31, 2013, were included in this retrospective study. The patient's survival 5 days after resuscitation defined the study end-point. For the statistical analysis, the mean, standard deviation, Student's t-test, Chi-square test, and logistic regression analyses were used (level of significance P< 0.05. Results: Arterial blood gas samples were taken from 170 patients. In particular, pH < 7.0 (odds ratio [OR]: 7.20; 95% confidence interval [CI]: 3.11–16.69; P< 0.001 and lactate ≥ 5.0 mmol/L (OR: 6.79; 95% CI: 2.77–16.66; P< 0.001 showed strong and independent correlations with mortality within the first 5 days after hospital admission. Conclusion: Our study results indicate that several arterial blood gas parameters correlate with mortality of patients after out-of-hospital resuscitation. The most relevant parameters are pH and lactate because they are strongly and independently associated with mortality within the first 5 days after resuscitation. Despite this correlation, none of these parameters by oneself is strong enough to allow an early prognostication. Still, these parameters can contribute as part of a multimodal approach to assessing the patients' prognosis.

  7. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  8. Diagnosis of arterial prosthetic graft infection by 111In oxine white blood cell scans

    International Nuclear Information System (INIS)

    McKeown, P.P.; Miller, D.C.; Jamieson, S.W.; Mitchell, R.S.; Reitz, B.A.; Olcott, C.; Mehigan, J.T.; Silberstein, R.J.; McDougall, I.R.

    1982-01-01

    Early and accurate diagnosis of infected prosthetic arterial grafts is difficult, despite the application of diverse diagnostic modalities. Delay in making the diagnosis is largely responsible for the high amputation and mortality rates associated with this complication. In nine patients with suspected graft infections, 111 In white blood cell scanning was useful and accurate. Graft infection was proved in five cases and ruled out in three. One false-positive scan was due to a sigmoid diverticular abscess overlying the graft. 111 In white blood cell scans may improve the accuracy of diagnosing infected prosthetic grafts, which may result in better limb and patient salvage rates

  9. Relationship between regional myocardial blood flow and thallium-201 distribution in the presence of coronary artery stenosis and dipyridamole-induced vasodilation

    International Nuclear Information System (INIS)

    Mays, A.E. Jr.; Cobb, F.R.

    1984-01-01

    This study assesses the relationship between the distribution of thallium-201 and myocardial blood flow during coronary vasodilation induced by intravenous dipyridamole in canine models of partial and complete coronary artery stenosis. 10 dogs were chronically instrumented with catheters in the left atrium and aorta and with a balloon occluder and electromagnetic flow probe on the proximal left circumflex coronary artery. Regional myocardial blood flow was measured during control conditions with radioisotope-labeled microspheres, and the phasic reactive hyperemic response to a 20-s transient occlusion was then recorded. Dipyridamole was then infused intravenously until phasic coronary blood flow increased to match peak hyperemic values. The left circumflex coronary artery was either partially occluded to reduce phasic blood flow to control values (group 1) or it was completely occluded (group 2), and thallium-201 and a second microsphere label were injected. 5 min later, the animals were sacrificed, the left ventricle was sectioned into 1-2-g samples, and thallium-201 activity and regional myocardial blood flow were measured. Curvilinear regression analyses between thallium-201 localization and myocardial blood flow during dipyridamole infusion demonstrated a slightly better fit to a second- as compared with a first-order model, indicating a slight roll-off of thallium activity as myocardial blood flow increases. During the dipyridamole infusion, the increases in phasic blood flow, the distributions of regional myocardial blood flow, and the relationships between thallium-201 localization and regional blood flow were comparable to values previously observed in exercising dogs with similar occlusions. These data provide basic validation that supports the use of intravenous dipyridamole and thallium-201 as an alternative to exercise stress and thallium-201 for evaluating the effects of coronary occlusive lesions on the distribution of regional myocardial blood flow

  10. Doppler Flow Wire Evaluation of Renal Blood Flow Reserve in Hypertensive Patients with Normal Renal Arteries

    International Nuclear Information System (INIS)

    Beregi, Jean-Paul; Mounier-Vehier, Claire; Devos, Patrick; Gautier, Corinne; Libersa, Christian; McFadden, Eugene P.; Carre, Alain

    2000-01-01

    Purpose: To study the vasomotor responses of the renal microcirculation in patients with essential hypertension.Methods: We studied the reactivity of the renal microcirculation to papaverine, with intraarterial Doppler and quantitative arteriography, in 34 renal arteries of 19 hypertensive patients without significant renal artery stenosis. Isosorbide dinitrate was given to maximally dilate proximal renal arteries. APV (average peak blood flow velocity) was used as an index of renal blood flow.Results: Kidneys could be divided into two distinct subgroups based on their response to papaverine. An increase in APV of up to 55% occurred in 21 kidneys, an increase > 55% in 13 kidneys. Within each group the values were normally distributed. Both baseline APV and the effect of papaverine on mean velocity differed significantly between groups.Conclusion: There seems to be a subgroup of patients with essential hypertension that has an impaired reactivity to papaverine, consistent with a functional impairment of the renal microcirculation. Further studies are required to determine whether this abnormality contributes to or results from elevated blood pressure

  11. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  12. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  13. Arterial Blood Supply to the Spinal Cord in Animal Models of Spinal Cord Injury. A Review.

    Science.gov (United States)

    Mazensky, David; Flesarova, Slavka; Sulla, Igor

    2017-12-01

    Animal models are used to examine the results of experimental spinal cord injury. Alterations in spinal cord blood supply caused by complex spinal cord injuries contribute significantly to the diversity and severity of the spinal cord damage, particularly ischemic changes. However, the literature has not completely clarified our knowledge of anatomy of the complex three-dimensional arterial system of the spinal cord in experimental animals, which can impede the translation of experimental results to human clinical applications. As the literary sources dealing with the spinal cord arterial blood supply in experimental animals are limited and scattered, the authors performed a review of the anatomy of the arterial blood supply to the spinal cord in several experimental animals, including pigs, dogs, cats, rabbits, guinea pigs, rats, and mice and created a coherent format discussing the interspecies differences. This provides researchers with a valuable tool for the selection of the most suitable animal model for their experiments in the study of spinal cord ischemia and provides clinicians with a basis for the appropriate translation of research work to their clinical applications. Anat Rec, 300:2091-2106, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. Two-Fluid Mathematical Models for Blood Flow in Stenosed Arteries: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2009-01-01

    Full Text Available The pulsatile flow of blood through stenosed arteries is analyzed by assuming the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a non-Newtonian fluid and the plasma in the peripheral layer as a Newtonian fluid. The non-Newtonian fluid in the core region of the artery is assumed as a (i Herschel-Bulkley fluid and (ii Casson fluid. Perturbation method is used to solve the resulting system of non-linear partial differential equations. Expressions for various flow quantities are obtained for the two-fluid Casson model. Expressions of the flow quantities obtained by Sankar and Lee (2006 for the two-fluid Herschel-Bulkley model are used to get the data for comparison. It is found that the plug flow velocity and velocity distribution of the two-fluid Casson model are considerably higher than those of the two-fluid Herschel-Bulkley model. It is also observed that the pressure drop, plug core radius, wall shear stress and the resistance to flow are significantly very low for the two-fluid Casson model than those of the two-fluid Herschel-Bulkley model. Hence, the two-fluid Casson model would be more useful than the two-fluid Herschel-Bulkley model to analyze the blood flow through stenosed arteries.

  15. Relationship between haemodynamic impairment and collateral blood flow in carotid artery disease.

    Science.gov (United States)

    Hartkamp, Nolan S; Petersen, Esben T; Chappell, Michael A; Okell, Thomas W; Uyttenboogaart, Maarten; Zeebregts, Clark J; Bokkers, Reinoud Ph

    2017-01-01

    Collateral blood flow plays a pivotal role in steno-occlusive internal carotid artery (ICA) disease to prevent irreversible ischaemic damage. Our aim was to investigate the effect of carotid artery disease upon cerebral perfusion and cerebrovascular reactivity and whether haemodynamic impairment is influenced at brain tissue level by the existence of primary and/or secondary collateral. Eighty-eight patients with steno-occlusive ICA disease and 29 healthy controls underwent MR examination. The presence of collaterals was determined with time-of-flight, two-dimensional phase contrast MRA and territorial arterial spin labeling (ASL) imaging. Cerebral blood flow and cerebrovascular reactivity were assessed with ASL before and after acetazolamide. Cerebral haemodynamics were normal in asymptomatic ICA stenosis patients, as opposed to patients with ICA occlusion, in whom the haemodynamics in both hemispheres were compromised. Haemodynamic impairment in the affected brain region was always present in symptomatic patients. The degree of collateral blood flow was inversely correlated with haemodynamic impairment. Recruitment of secondary collaterals only occurred in symptomatic ICA occlusion patients. In conclusion, both CBF and cerebrovascular reactivity were found to be reduced in symptomatic patients with steno-occlusive ICA disease. The presence of collateral flow is associated with further haemodynamic impairment. Recruitment of secondary collaterals is associated with severe haemodynamic impairment.

  16. Effects of two newly synthesized analogues of lidocaine on rat arterial blood pressure and heart rate.

    Science.gov (United States)

    Al Rasheed, N M; Al Sayed, M I; Al Zuhair, H H; Al Obaid, A R; Fatani, A J

    2001-04-01

    Two new analogues of lidocaine were synthesized at the College of Pharmacy, King Saud University: compound I (Methyl-2-[2-(N,N-diethylamino) acetamido]-3-cyano-4,5-dimethylbenzoate) and compound II (Methyl-2-[2-(piperidino) acetamido]-3-cyano-4,5-dimethylbenzoate). Their influence on the arterial blood pressure and the heart rate of urethane-anaesthetized rats was studied and compared with the actions of lidocaine. Compounds I, II and lidocaine induced significant dose-dependent decreases in the arterial blood pressure and heart rate, which usually returned to basal values within 3-5 min. There were significant differences in the potency of the three compounds in producing their effects on blood pressure and heart rate (Plidocaine and compound I, respectively. The results of this study also indicated the ineffectiveness of antagonists of autonomic, histaminergic and 5-HT receptor, and various vasodilators in blocking the actions of the three compounds on blood pressure and heart rate. Pretreatment with CaCl(2)significantly reduced the hypotension and bradycardia induced by the three compounds, suggesting the involvement of calcium channels, probably of the L type. Several possible mechanisms are postulated. In conclusion, the results direct attention to the capability of the two new compounds to decrease blood pressure and heart rate; affects that may have clinical potential. Copyright 2001 Academic Press.

  17. Cerebral blood flow response to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Kern, F.H.; Ungerleider, R.M.; Quill, T.J.; Baldwin, B.; White, W.D.; Reves, J.G.; Greeley, W.J.

    1991-01-01

    We examined the relationship of changes in partial pressure of carbon dioxide on cerebral blood flow responsiveness in 20 pediatric patients undergoing hypothermic cardiopulmonary bypass. Cerebral blood flow was measured during steady-state hypothermic cardiopulmonary bypass with the use of xenon 133 clearance methodology at two different arterial carbon dioxide tensions. During these measurements there was no significant change in mean arterial pressure, nasopharyngeal temperature, pump flow rate, or hematocrit value. Cerebral blood flow was found to be significantly greater at higher arterial carbon dioxide tensions (p less than 0.01), so that for every millimeter of mercury rise in arterial carbon dioxide tension there was a 1.2 ml.100 gm-1.min-1 increase in cerebral blood flow. Two factors, deep hypothermia (18 degrees to 22 degrees C) and reduced age (less than 1 year), diminished the effect carbon dioxide had on cerebral blood flow responsiveness but did not eliminate it. We conclude that cerebral blood flow remains responsive to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in infants and children; that is, increasing arterial carbon dioxide tension will independently increase cerebral blood flow

  18. Performance evaluation of continuous blood sampling system for PET study. Comparison of three detector-systems

    CERN Document Server

    Matsumoto, K; Sakamoto, S; Senda, M; Yamamoto, S; Tarutani, K; Minato, K

    2002-01-01

    To measure cerebral blood flow with sup 1 sup 5 O PET, it is necessary to measure the time course of arterial blood radioactivity. We examined the performance of three different types of continuous blood sampling system. Three kinds of continuous blood sampling system were used: a plastic scintillator-based beta detector (conventional beta detector (BETA)), a bismuth germinate (BGO)-based coincidence gamma detector (Pico-count flow-through detector (COINC)) and a Phoswich detector (PD) composed by a combination of plastic scintillator and BGO scintillator. Performance of these systems was evaluated for absolute sensitivity, count rate characteristic, sensitivity to background gamnra photons, and reproducibility for nylon tube geometry. The absolute sensitivity of the PD was 0.21 cps/Bq for sup 6 sup 8 Ga positrons at the center of the detector. This was approximately three times higher than BETA, two times higher than COINC. The value measured with BETA was stable, even when background radioactivity was incre...

  19. Relationship between preoperative radial artery and postoperative arteriovenous fistula blood flow in hemodialysis patients.

    Science.gov (United States)

    Sato, Michiko; Io, Hiroaki; Tanimoto, Mitsuo; Shimizu, Yoshio; Fukui, Mitsumine; Hamada, Chieko; Horikoshi, Satoshi; Tomino, Yasuhiko

    2012-01-01

    It is recommended that arteriovenous fistula (AVF) blood flow should be more than 425 ml/min before cannulation. However, the relationship between preoperative radial artery flow (RAF) and postoperative AVF blood flow has still not been examined. Sixty-one patients with end-stage kidney disease (ESKD) were examined. They had an AVF prepared at Juntendo University Hospital from July 2006 through August 2007. Preoperative RAF and postoperative AVF blood flows were measured by ultrasonography. AVF blood flow gradually increased after the operation. AVF blood flow was significantly correlated with preoperative RAF. When preoperative RAF exceeded 21.4 ml/min, AVF blood flow rose to more than 425 ml/min. The postoperative AVF blood flow in the group with RAF of more than 20 ml/min was significantly higher than that in those with less than 20 ml/min. Preoperative RAF of less than 20 ml/min had a significantly high risk of primary AVF failure within 8 months compared with that of more than 20 ml/min. It appears that measurement of RAF by ultrasonography is useful for estimating AVF blood flow postoperatively and can predict the risk of complications in ESKD patients.

  20. Quantifying regional cerebral blood flow with N-isopropyl-p-[123I]iodoamphetamine and SPECT by one-point sampling method

    International Nuclear Information System (INIS)

    Odano, Ikuo; Takahashi, Naoya; Noguchi, Eikichi; Ohtaki, Hiro; Hatano, Masayoshi; Yamazaki, Yoshihiro; Higuchi, Takeshi; Ohkubo, Masaki.

    1994-01-01

    We developed a new non-invasive technique; one-point sampling method, for quantitative measurement of regional cerebral blood flow (rCBF) with N-isopropyl-p-[ 123 I]iodoamphetamine and SPECT. Although the continuous withdrawal of arterial blood and octanol treatment of the blood are required in the conventional microsphere method, the new technique dose not require these two procedures. The total activity of 123 I-IMP obtained by the continuous withdrawal of arterial blood is inferred by the activity of 133 I-IMP obtained by the one point arterial sample using a regression line. To determine when one point sampling time was optimum for inferring integral input function of the continuous withdrawal and whether the treatment of sampled blood for octanol fraction was required, we examined a correlation between the total activity of arterial blood withdrawn from 0 to 5 min after the injection and the activity of one point sample obtained at time t, and calculated a regression line. As a result, the minimum % error for the inference using the regression line was obtained at 6 min after the 123 I-IMP injection, moreover, the octanol treatment was not required. Then examining an effect on the values of rCBF when the sampling time was deviated from 6 min, we could correct the values in approximately 3% error when the sample was obtained at 6±1 min after the injection. The one-point sampling method provides accurate and relatively non-invasive measurement of rCBF without octanol extraction of arterial blood. (author)

  1. EFFECT OF LISINOPRIL ON 24-HOUR BLOOD PRESSURE AND ARTERIAL STIFFNESS IN PATIENTS WITH ARTERIAL HYPERTENSION AND RHEUMATOID ARTHRITIS

    Directory of Open Access Journals (Sweden)

    O. L. Sarkisova

    2017-01-01

    Full Text Available Aim. To study effect of 24-week treatment with lisinopril on blood pressure (BP and arterial stiffness in patients with arterial hypertension (HT and rheumatoid arthritis (RA.Material and methods. Twenty patients with essential HT grade  1-2 and RA (mean age 60.2±7.9 years were treated with lisinoprilin 24 weeks in open controlled study. Office blood pressure (BP was 147.2±9.4/87.5±8.6 mm Hg; 24-h mean  BP – 141.8±9.3/82.2±9.6 mm Hg; HT duration was 14.5±9.4 years, and RA duration – 12.3±2.6 years. A high incidence of traditional cardiovascular risk factors was identified: 95% of patients had dyslipidaemia, 45% – obesity, 35% – impaired glucose tolerance. Atherosclerosis of carotid arteries with stenosis less than 25% was diagnosed in 65% of patients. Most patients had a positive rheumatoid factor and cyclic citrullinated peptide antibodies, as well as moderate RA activity and III-IV radiologic stage of RA. All patients received methotrexate as the basic anti-inflammatory drug, 12 (60% patients – selective cyclooxygenase-2 inhibitors, 6 (30% patients took corticosteroids equivalent to prednisolone 7.5±5.5 mg per day. Mean  dose  of lisinopril was 12.2±9.8 mg/day. Office BP measurements, 24-hour ambulatory BP monitoring (ABPM, and  arterial stiffness evaluation were  performed initially and  at the end of the study. Arterial stiffness was assessed by cardio-ankle vascular index on the right (R-CAVI and on the left (L-CAVI.Results. After 24-week therapy with lisinopril office systolic and diastolic BP significantly decreased by 16.0±7.2/11.6±9.1 mm Hg (p<0.0001 and 11.6±9.1 mm Hg (p<0.0001, respectively. The target BP was achieved in 16 (83% patients. According to the ABPM 24-week therapy with lisino pril led to a significant (p<0.002 decrease in BP for all referable periods: by 12.4±9.1/7.6±3.9 mm Hg within 24 hours;  by 13.4±10.1/8.0±6.1 mm Hg for daytime; by 10.1±9.3/7.3±6.3 mm Hg for night-time. After

  2. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  3. Relationship of 133Xe cerebral blood flow to middle cerebral arterial flow velocity in men at rest

    Science.gov (United States)

    Clark, J. M.; Skolnick, B. E.; Gelfand, R.; Farber, R. E.; Stierheim, M.; Stevens, W. C.; Beck, G. Jr; Lambertsen, C. J.

    1996-01-01

    Cerebral blood flow (CBF) was measured by 133Xe clearance simultaneously with the velocity of blood flow through the left middle cerebral artery (MCA) over a wide range of arterial PCO2 in eight normal men. Average arterial PCO2, which was varied by giving 4% and 6% CO2 in O2 and by controlled hyperventilation on O2, ranged from 25.3 to 49.9 mm Hg. Corresponding average values of global CBF15 were 27.2 and 65.0 ml 100 g min-1, respectively, whereas MCA blood-flow velocity ranged from 42.8 to 94.2 cm/s. The relationship of CBF to MCA blood-flow velocity over the imposed range of arterial PCO2 was described analytically by a parabola with the equation: CBF = 22.8 - 0.17 x velocity + 0.006 x velocity2 The observed data indicate that MCA blood-flow velocity is a useful index of CBF response to change in arterial PCO2 during O2 breathing at rest. With respect to baseline values measured while breathing 100% O2 spontaneously, percent changes in velocity were significantly smaller than corresponding percent changes in CBF at increased levels of arterial PCO2 and larger than CBF changes at the lower arterial PCO2. These observed relative changes are consistent with MCA vasodilation at the site of measurement during exposure to progressive hypercapnia and also during extreme hyperventilation hypocapnia.

  4. Evaluation of the carotid artery stenosis based on minimization of mechanical energy loss of the blood flow.

    Science.gov (United States)

    Sia, Sheau Fung; Zhao, Xihai; Li, Rui; Zhang, Yu; Chong, Winston; He, Le; Chen, Yu

    2016-11-01

    Internal carotid artery stenosis requires an accurate risk assessment for the prevention of stroke. Although the internal carotid artery area stenosis ratio at the common carotid artery bifurcation can be used as one of the diagnostic methods of internal carotid artery stenosis, the accuracy of results would still depend on the measurement techniques. The purpose of this study is to propose a novel method to estimate the effect of internal carotid artery stenosis on the blood flow based on the concept of minimization of energy loss. Eight internal carotid arteries from different medical centers were diagnosed as stenosed internal carotid arteries, as plaques were found at different locations on the vessel. A computational fluid dynamics solver was developed based on an open-source code (OpenFOAM) to test the flow ratio and energy loss of those stenosed internal carotid arteries. For comparison, a healthy internal carotid artery and an idealized internal carotid artery model have also been tested and compared with stenosed internal carotid artery in terms of flow ratio and energy loss. We found that at a given common carotid artery bifurcation, there must be a certain flow distribution in the internal carotid artery and external carotid artery, for which the total energy loss at the bifurcation is at a minimum; for a given common carotid artery flow rate, an irregular shaped plaque at the bifurcation constantly resulted in a large value of minimization of energy loss. Thus, minimization of energy loss can be used as an indicator for the estimation of internal carotid artery stenosis.

  5. Fourier Analysis of Peripheral Blood Pressure and Flow in Intraoperative Assessment of Infrainguinal Arterial Reconstructions

    Directory of Open Access Journals (Sweden)

    Cheshmedzhiev Mihail V.

    2014-08-01

    Full Text Available AIM: To assess infrainguinal arterial reconstructions by intraoperative flowmetry under the distal anastomosis using a fast Fourier transformation; calculate and compare the amplitude ratios of peripheral arterial blood pressure and volume flow before and after drug-induced vasodilation of occluded bypass grafts and bypass grafts that have been patent at least for 1 year. To find what magnitude of the change of these ratios indicate a long-term patency of the bypass grafting. PATIENTS AND METHODS: We compared the results of the intraoperative flowmetry tests of 97 patients with infrainguinal arterial reconstructions. The patients were divided into two groups based on the graft status: the grafts in 49 patients were patent for at least a year, and 48 patients had failed bypass. We used a fast Fourier transform (FFT of the pressure and blood flow waves and compared the ratios of their amplitudes before and after administration of a vasodilator drug into the graft. Comparing the ratios obtained before and those after administration of the drug we quantified their change in each group and analysed them. RESULTS: After a drug-induced vasodilation, the blood pressure and flow amplitude ratios for the group with compromised reconstructions were less than 1.9 times smaller than those before drug infusion, while for the group with bypass grafts that had been functional for at least 12 months the ratios declined by more than 1.9≈2 times. CONCLUSION: The magnitude of the change of amplitude ratios of the peripheral pressure and volume flow after drug-induced vasodilation can be used to make an assessment of the bypass graft and the distal arterial segment.

  6. Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

    Science.gov (United States)

    Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.

    2013-09-01

    Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.

  7. Downstream Hepatic Arterial Blood Pressure Changes Caused by Deployment of the Surefire AntiReflux Expandable Tip

    International Nuclear Information System (INIS)

    Rose, Steven C.; Kikolski, Steven G.; Chomas, James E.

    2013-01-01

    Purpose: The purpose of this work was to evaluate blood pressure changes caused by deployment of the Surefire antireflux expandable tip. The pressure measurements are relevant because they imply changes in hepatoenteric arterial blood flow within this liver compartment during hepatic artery delivery of cytotoxic agents. Methods: After positioning the Surefire antireflux system in the targeted hepatic artery, blood pressure was obtained initially with the tip collapsed (or through a femoral artery sheath), then again after the tip was expanded before chemoembolization or yttrium 90 ( 90 Y) radioembolization. Results: Eighteen patients with liver malignancy underwent 29 procedures in 29 hepatic arteries (3 common hepatic, 22 lobar, 4 segmental). Systolic, diastolic, and mean blood pressure were all decreased by a mean of 29 mm Hg (p = 0.000004), 14 mm Hg (p = 0.0000004), and 22 mm Hg (p = 0.00000001), respectively. Conclusion: When the Surefire expandable tip is deployed to prevent retrograde reflux of agents, it also results in a significant decrease in blood pressure in the antegrade distribution, potentially resulting in hepatopedal blood flow in vessels that are difficult to embolize, such as the supraduodenal arteries

  8. Development of blood extraction system designed by female mosquito's blood sampling mechanism for bio-MEMS

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2005-02-01

    A compact and wearable wristwatch type Bio-MEMS such as a health monitoring system (HMS) to detect blood sugar level for diabetic patient, was newly developed. The HMS consists of (1) a indentation unit with a microneedle to generate the skin penetration force using a shape memory alloy(SMA) actuator, (2) a pumping unit using a bimorph PZT piezoelectric actuator to extract the blood and (3) a gold (Au) electrode as a biosensor immobilized GOx and attached to the gate electrode of MOSFET to detect the amount of Glucose in extracted blood. GOx was immobilized on a self assembled spacer combined with an Au electrode by the cross-link method using BSA as an additional bonding material. The device can extract blood in a few microliter through a painless microneedle with the negative pressure by deflection of the bimorph PZT piezoelectric actuator produced in the blood chamber, by the similar way the female mosquito extracts human blood with muscle motion to flex or relax. The performances of the liquid sampling ability of the pumping unit through a microneedle (3.8mm length, 100μm internal diameter) using the bimorph PZT piezoelectric microactuator were measured. The blood extraction micro device could extract human blood at the speed of 2μl/min, and it is enough volume to measure a glucose level, compared to the amount of commercial based glucose level monitor. The electrode embedded in the blood extraction device chamber could detect electrons generated by the hydrolysis of hydrogen peroxide produced by the reaction between GOx and glucose in a few microliter extracted blood, using the constant electric current measurement system of the MOSFET type hybrid biosensor. The output voltage for the glucose diluted in the chamber was increased lineally with increase of the glucose concentration.

  9. On-chip sample preparation for complete blood count from raw blood.

    Science.gov (United States)

    Nguyen, John; Wei, Yuan; Zheng, Yi; Wang, Chen; Sun, Yu

    2015-03-21

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new 'offset' filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100,000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.

  10. Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, Zoran [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Roessle, Martin; Schultheiss, Michael [University Medical Center Freiburg, Department of Gastroenterology, Freiburg (Germany); Euringer, Wulf; Langer, Mathias [University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Salem, Riad; Barker, Alex; Carr, James; Collins, Jeremy D. [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2015-09-15

    To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA accelerated non-contrast 4D flow MRI of the liver vasculature was applied with acceleration factor R = 5 at 3Tesla. Flow analysis included three-dimensional (3D) blood flow visualization using time-resolved 3D particle traces and semi-quantitative flow pattern grading. Quantitative evaluation entailed peak velocities and net flows throughout the arterial and portal venous (PV) systems. MRI measurements were taken within 24 h before and 4 weeks after TIPS placement. Three-dimensional flow visualization with 4D flow MRI revealed good image quality with minor limitations in PV flow. Quantitative analysis revealed a significant increase in PV flow (562 ± 373 ml/min before vs. 1831 ± 965 ml/min after TIPS), in the hepatic artery (176 ± 132 ml/min vs. 354 ± 140 ml/min) and combined flow in splenic and superior mesenteric arteries (770 ml/min vs. 1064 ml/min). Shunt-flow assessment demonstrated stenoses in two patients confirmed and treated at TIPS revision. Four-dimensional flow MRI might have the potential to give new information about the effect of TIPS placement on hepatic perfusion. It may explain some unexpected findings in clinical observation studies. (orig.)

  11. Wall morphology, blood flow and wall shear stress: MR findings in patients with peripheral artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Galizia, Mauricio S.; Barker, Alex; Collins, Jeremy; Carr, James [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Liao, Yihua [Northwestern University' s Feinberg School of Medicine, Department of Preventive Medicine, Chicago, IL (United States); McDermott, Mary M. [Northwestern University' s Feinberg School of Medicine, Department of Preventive Medicine, Chicago, IL (United States); Northwestern University' s Feinberg School of Medicine, Department of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2014-04-15

    To investigate the influence of atherosclerotic plaques on femoral haemodynamics assessed by two-dimensional (2D) phase-contrast (PC) magnetic resonance imaging (MRI) with three-directional velocity encoding. During 1 year, patients with peripheral artery disease and an ankle brachial index <1.00 were enrolled. After institutional review board approval and written informed consent, 44 patients (age, 70 ± 12 years) underwent common femoral artery MRI. Patients with contra-indications for MRI were excluded. Sequences included 2D time-of-flight, proton-density, T1-weighted and T2-weighted MRI. Electrocardiogram (ECG)-gated 2D PC-MRI with 3D velocity encoding was acquired. A radiologist classified images in five categories. Blood flow, velocity and wall shear stress (WSS) along the vessel circumference were quantified from the PC-MRI data. The acquired images were of good quality for interpretation. There were no image quality problems related to poor ECG-gating or slice positioning. Velocities, oscillatory shear stress and total flow were similar between patients with normal arteries and wall thickening/plaque. Patients with plaques demonstrated regionally increased peak systolic WSS and enhanced WSS eccentricity. Combined multi-contrast morphological imaging of the peripheral arterial wall with PC-MRI with three-directional velocity encoding is a feasible technique. Further study is needed to determine whether flow is an appropriate marker for altered endothelial cell function, vascular remodelling and plaque progression. (orig.)

  12. Effect of Acute Resistance Exercise on Carotid Artery Stiffness and Cerebral Blood Flow Pulsatility

    Directory of Open Access Journals (Sweden)

    Wesley K Lefferts

    2014-03-01

    Full Text Available Arterial stiffness is associated with cerebral flow pulsatility. Arterial stiffness increases following acute resistance exercise (RE. Whether this acute RE-induced vascular stiffening affects cerebral pulsatility remains unknown. Purpose: To investigate the effects of acute RE on common carotid artery (CCA stiffness and cerebral blood flow velocity (CBFv pulsatility. Methods: Eighteen healthy men (22 ± 1 yr; 23.7 ± 0.5 kg∙m-2 underwent acute RE (5 sets, 5-RM bench press, 5 sets 10-RM bicep curls with 90 s rest intervals or a time control condition (seated rest in a randomized order. CCA stiffness (β-stiffness, Elastic Modulus (Ep and hemodynamics (pulsatility index, forward wave intensity and reflected wave intensity were assessed using a combination of Doppler ultrasound, wave intensity analysis and applanation tonometry at baseline and 3 times post-RE. CBFv pulsatility index was measured with transcranial Doppler at the middle cerebral artery (MCA. Results: CCA β-stiffness, Ep and CCA pulse pressure significantly increased post-RE and remained elevated throughout post-testing (p 0.05. There were significant increases in forward wave intensity post-RE (p0.05. Conclusion: Although acute RE increases CCA stiffness and pressure pulsatility, it may not affect CCA or MCA flow pulsatility. Increases in pressure pulsatility may be due to increased forward wave intensity and not pressure from wave reflections.

  13. Patient Specific Multiscale Simulations of Blood Flow in Coronary Artery Bypass Surgery

    Science.gov (United States)

    Bangalore Ramachandra, Abhay; Sankaran, Sethuraman; Kahn, Andrew M.; Marsden, Alison L.

    2013-11-01

    Coronary artery bypass surgery is performed to revascularize blocked coronary arteries in roughly 400,000 patients per year in the US.While arterial grafts offer superior patency, vein grafts are used in more than 70% of procedures, as most patients require multiple grafts. Vein graft failure (approx. 50% within 10 years) remains a major clinical issue. Mounting evidence suggests that hemodynamics plays a key role as a mechano-biological stimulus contributing to graft failure. However, quantifying relevant hemodynamic quantities (e.g. wall shear stress) invivo is not possible directly using clinical imaging techniques. We numerically compute graft hemodynamics in a cohort of 3-D patient specific models using a stabilized finite element method. The 3D flow domain is coupled to a 0D lumped parameter circulatory model. Boundary conditions are tuned to match patient specific blood pressures, stroke volumes & heart rates. Results reproduce clinically observed coronary flow waveforms. We quantify differences in multiple hemodynamic quantities between arterial & venous grafts & discuss possible correlations between graft hemodynamics & clinically observed graft failure.Such correlations will provide further insight into mechanisms of graft failure and may lead to improved clinical outcomes.

  14. Spiral blood flows in an idealized 180-degree curved artery model

    Science.gov (United States)

    Bulusu, Kartik V.; Kulkarni, Varun; Plesniak, Michael W.

    2017-11-01

    Understanding of cardiovascular flows has been greatly advanced by the Magnetic Resonance Velocimetry (MRV) technique and its potential for three-dimensional velocity encoding in regions of anatomic interest. The MRV experiments were performed on a 180-degree curved artery model using a Newtonian blood analog fluid at the Richard M. Lucas Center at Stanford University employing a 3 Tesla General Electric (Discovery 750 MRI system) whole body scanner with an eight-channel cardiac coil. Analysis in two regions of the model-artery was performed for flow with Womersley number=4.2. In the entrance region (or straight-inlet pipe) the unsteady pressure drop per unit length, in-plane vorticity and wall shear stress for the pulsatile, carotid artery-based flow rate waveform were calculated. Along the 180-degree curved pipe (curvature ratio =1/7) the near-wall vorticity and the stretching of the particle paths in the vorticity field are visualized. The resultant flow behavior in the idealized curved artery model is associated with parameters such as Dean number and Womersley number. Additionally, using length scales corresponding to the axial and secondary flow we attempt to understand the mechanisms leading to the formation of various structures observed during the pulsatile flow cycle. Supported by GW Center for Biomimetics and Bioinspired Engineering (COBRE), MRV measurements in collaboration with Prof. John K. Eaton and, Dr. Chris Elkins at Stanford University.

  15. Blood flow quantification from 2D phase contrast MRI in renal arteries using an unsupervised data driven approach

    Energy Technology Data Exchange (ETDEWEB)

    Zoellner, Frank Gerrit [Computer Assisted Clinical Medicine, Faculty of Medicine Mannheim, Univ. of Heidelberg, Mannheim (Germany); Section for Radiology, Dept. of Surgical Sciences, Univ. of Bergen (Norway); Monssen, Jan Ankar [Dept. of Radiology, Haukeland Univ. Hospital, Bergen (Norway); Roervik, Jarie [Section for Radiology, Dept. of Surgical Sciences, Univ. of Bergen (Norway); Dept. of Radiology, Haukeland Univ. Hospital, Bergen (Norway); Lundervold, Arvid [Dept. of Radiology, Haukeland Univ. Hospital, Bergen (Norway); Dept. of Biomedicine, Univ. of Bergen (Norway); Schad, Lothar R. [Computer Assisted Clinical Medicine, Faculty of Medicine Mannheim, Univ. of Heidelberg, Mannheim (Germany)

    2009-07-01

    We present a clustering approach to segment the renal artery from 2D PC Cine MR images to measure arterial blood velocity and flow. Such information is important in grading renal artery stenosis and to support the decision on surgical interventions like percutaneous transluminal angioplasty. Results from 20 data sets (volunteers, 7 patients) show that the renal arteries could be extracted automatically and the corresponding velocity profiles were close (r = 0.977) to that obtained by manual delineations of the vessel areas. (orig.)

  16. Blood flow quantification from 2D phase contrast MRI in renal arteries using an unsupervised data driven approach

    International Nuclear Information System (INIS)

    Zoellner, Frank Gerrit; Monssen, Jan Ankar; Roervik, Jarie; Lundervold, Arvid; Schad, Lothar R.

    2009-01-01

    We present a clustering approach to segment the renal artery from 2D PC Cine MR images to measure arterial blood velocity and flow. Such information is important in grading renal artery stenosis and to support the decision on surgical interventions like percutaneous transluminal angioplasty. Results from 20 data sets (volunteers, 7 patients) show that the renal arteries could be extracted automatically and the corresponding velocity profiles were close (r = 0.977) to that obtained by manual delineations of the vessel areas. (orig.)

  17. Roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction.

    Science.gov (United States)

    Liu, Jia-Ming; Shen, Jian-Xiong; Zhang, Jian-Guo; Zhao, Hong; Li, Shu-Gang; Zhao, Yu; Qiu, Giu-Xing

    2012-01-01

    It has been stated that preoperative pulmonary function tests are essential to assess the surgical risk in patients with scoliosis. Arterial blood gas tests have also been used to evaluate pulmonary function before scoliotic surgery. However, few studies have been reported. The aim of this study was to investigate the roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction. This study involved scoliotic patients with moderate or severe pulmonary dysfunction (forced vital capacity treatment between January 2002 and April 2010. A total of 73 scoliotic patients (23 males and 50 females) with moderate or severe pulmonary dysfunction were included. The average age of the patients was 16.53 years (ranged 10 - 44). The demographic distribution, medical records, and radiographs of all patients were collected. All patients received arterial blood gas tests and pulmonary function tests before surgery. The arterial blood gas tests included five parameters: partial pressure of arterial oxygen, partial pressure of arterial carbon dioxide, alveolar-arterial oxygen tension gradient, pH, and standard bases excess. The pulmonary function tests included three parameters: forced expiratory volume in 1 second ratio, forced vital capacity ratio, and peak expiratory flow ratio. All five parameters of the arterial blood gas tests were compared between the two groups with or without postoperative pulmonary complications by variance analysis. Similarly, all three parameters of the pulmonary function tests were compared. The average coronal Cobb angle before surgery was 97.42° (range, 50° - 180°). A total of 15 (20.5%) patients had postoperative pulmonary complications, including hypoxemia in 5 cases (33.3%), increased requirement for postoperative ventilatory support in 4 (26.7%), pneumonia in 2 (13.3%), atelectasis in 2 (13.3%), pneumothorax in 1 (6.7%), and hydrothorax in 1 (6.7%). No significant differences

  18. The effects of hypotension on differences between the results of simultaneous venous and arterial blood gas analysis

    Directory of Open Access Journals (Sweden)

    Farhad Shirani

    2011-01-01

    Full Text Available Background: Analysis of venous blood gas (VBG can represent arterial blood gas (ABG analysis in patients with various diseases. The effects of hypotension on differences between the results of simultaneous venous and arterial blood gas analyses were reviewed. Methods: This observational, cross-sectional study was conducted from March to October 2010 in emergency depart-ments of two university hospitals in Tehran (Iran on consecutive adult patients for whom ABG had been indicated for diagnosis/treatment. Arterial and peripheral venous bloods were simultaneously sampled with blood pressure measure-ment. The VBG-ABG amount of difference regarding pH, HCO 3 , PCO 2 , PO 2 , SO 2 , and Base Excess (BE was com-pared between those with and without hypotension. Results: During the study, 192 patients (51.6 ± 23.6 years, 67.7% males were entered into the hypotension (n = 78 and normotensive groups (n = 114. The average VBG-ABG amount of difference (95% limits of agreement in the hypotension versus normotensive group were -0.030 (-0.09 to 0.03 vs. -0.016 (-0.1 to 0.068 for pH (p = 0.01, 1.79 (-1.91 to 5.49 vs. 1.32 (-1.94 to 4.58 mEq/L for HCO 3 (p = 0.032, 2.69 (-20.43 to 25.81 vs. 2.03 (-7.75 to 11.81 mmHg for PCO 2 (p = 0.295, -35.97 (-130.17 to 58.23 vs. -32.65 (-104.79 to 39.49 mmHg for PO 2 (p = 0.293, -18.58 (-14.66 to 51.82 vs. -9.06 (-31.28 to 13.16 percent (p < 0.001 for SO 2 , and 0.25 (-3.73 to 4.23 vs. 0.79 (-2.51 to 4.09 for BE (p = 0.036. Conclusions: Hypotensive status is associated with an increase in the amount of difference between VBG and ABG analysis regarding pH, HCO 3 , and BE, though the amount of increase does not seem to be clinically important. Studying the precise effects of replacing ABG with VBG on the clinical decision-making and the following outcomes is worth-while.

  19. Basic arterial blood gas biomarkers as a predictor of mortality in tetralogy of Fallot patients.

    Science.gov (United States)

    Bhardwaj, Vandana; Kapoor, Poonam Malhotra; Irpachi, Kalpana; Ladha, Suruchi; Chowdhury, Ujjwal Kumar

    2017-01-01

    Serum lactate and base deficit have been shown to be a predictor of morbidity and mortality in critically ill patients. Poor preoperative oxygenation appears to be one of the significant factors that affects early mortality in tetralogy of Fallot (TOF). There is little published literature evaluating the utility of serum lactate, base excess (BE), and oxygen partial pressure (PO 2 ) as simple, widely available, prognostic markers in patients undergoing surgical repair of TOF. This prospective, observational study was conducted in 150 TOF patients, undergoing elective intracardiac repair. PO 2 , BE, and lactate levels at three different time intervals were recorded. Arterial blood samples were collected after induction (T1), after cardiopulmonary bypass (T2), and 48 h (T3) after surgery in the Intensive Care Unit (ICU). To observe the changes in PO 2 , BE, and lactate levels over a period of time, repeated measures analysis was performed with Bonferroni method. The receiver operating characteristics (ROC) analysis was used to find area under curve (AUC) and cutoff values of various biomarkers for predicting mortality in ICU. The patients who could not survive showed significant elevated lactate levels at baseline (T1) and postoperatively (T2) as compared to patients who survived after surgery (P curve analysis showed that lactate levels (T3) have highest mortality predictive value (AUC: 96.9%) as compared to BE (AUC: 94.5%) and PO 2 (AUC: 81.1%). Serum lactate and BE may be used as prognostic markers to predict mortality in patients undergoing TOF repair. The routine analysis of these simple, fast, widely available, and cost-effective biomarkers should be encouraged to predict prognosis of TOF patients.

  20. Effects of preoperative aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in patients undergoing off-pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Shim, Jae Kwang; Choi, Yong Seon; Oh, Young Jun; Bang, Sou Ouk; Yoo, Kyung Jong; Kwak, Young Lan

    2007-07-01

    Preoperative exposure to clopidogrel and aspirin significantly increases postoperative bleeding in patients undergoing on-pump coronary artery bypass graft surgery. Off-pump coronary bypass grafting has been proposed as an alternative technique to attenuate postoperative bleeding associated with clopidogrel. This study aimed to determine the effects of aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in off-pump coronary artery bypass grafting. One hundred six patients scheduled for off-pump coronary artery bypass grafting were divided into three groups: aspirin and clopidogrel discontinued more than 6 days before surgery (group 1, n = 35), aspirin and clopidogrel continued until 3 to 5 days before surgery (group 2, n = 51), and both medications continued within 2 days of surgery (group 3, n = 20). Thromboelastographic tracings were analyzed before induction of anesthesia. Routine coagulation profiles were measured before and after surgery. A cell salvage device was used during surgery and salvaged blood was reinfused. Chest tube drainage and blood transfusion requirement were recorded postoperatively. Patient characteristics, operative data, and thromboelastographic tracings were similar among the groups. There were significant decreases in hematocrit level and platelet count and prolongation in prothrombin time postoperatively in all groups without any intergroup differences. The amounts of perioperative blood loss and blood transfusion required were all similar among the groups. Preoperative clopidogrel and aspirin exposure even within 2 days of surgery does not increase perioperative blood loss and blood transfusion requirements in patients undergoing elective off-pump coronary artery bypass grafting.

  1. Quantitative agreement between [(15)O]H2O PET and model free QUASAR MRI-derived cerebral blood flow and arterial blood volume

    NARCIS (Netherlands)

    Heijtel, D. F. R.; Petersen, E. T.; Mutsaerts, H. J. M. M.; Bakker, E.; Schober, P.; Stevens, M. F.; van Berckel, B. N. M.; Majoie, C. B. L. M.; Booij, J.; van Osch, M. J. P.; van Bavel, E. T.; Boellaard, R.; Lammertsma, A. A.; Nederveen, A. J.

    2016-01-01

    The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week

  2. Arterial blood gas management in retrograde cerebral perfusion: the importance of carbon dioxide.

    Science.gov (United States)

    Ueno, K; Takamoto, S; Miyairi, T; Morota, T; Shibata, K; Murakami, A; Kotsuka, Y

    2001-11-01

    Many interventional physiological assessments for retrograde cerebral perfusion (RCP) have been explored. However, the appropriate arterial gas management of carbon dioxide (CO2) remains controversial. The aim of this study is to determine whether alpha-stat or pH-stat could be used for effective brain protection under RCP in terms of cortical cerebral blood flow (CBF), cerebral metabolic rate for oxygen (CMRO2), and distribution of regional cerebral blood flow. Fifteen anesthetized dogs (25.1+/-1.1 kg) on cardiopulmonary bypass (CPB) were cooled to 18 degrees C under alpha-stat management and had RCP for 90 min under: (1), alpha-stat; (2), pH-stat; or (3), deep hypothermic (18 degrees C) antegrade CPB (antegrade). RCP flow was regulated for a sagittal sinus pressure of around 25 mmHg. CBF was monitored by a laser tissue flowmeter. Serial analyses of blood gas were made. The regional cerebral blood flow was measured with colored microspheres before discontinuation of RCP. CBF and CMRO2 were evaluated as the percentage of the baseline level (%CBF, %CMRO2). The oxygen content of arterial inflow and oxygen extraction was not significantly different between the RCP groups. The %CBF and %CMRO2 were significantly higher for pH-stat RCP than for alpha-stat RCP. The regional cerebral blood flow, measured with colored microspheres, tended to be higher for pH-stat RCP than for alpha-stat RCP, at every site in the brain. Irrespective of CO2 management, regional differences were not significant among any site in the brain. CO2 management is crucial for brain protection under deep hypothermic RCP. This study revealed that pH-stat was considered to be better than alpha-stat in terms of CBF and oxygen metabolism in the brain. The regional blood flow distribution was considered to be unchanged irrespective of CO2 management.

  3. The relationship between fasting blood glucose variability and coronary artery collateral formation in type 2 diabetes patients with coronary artery disease.

    Science.gov (United States)

    Cheng, Gang; Mahmoudi, Hilda; Chokshi, Binna; Fernandez, Marlena; Kazemi, Vahid; Lamaa, Nader

    2017-09-01

    Coronary collaterals are an alternative source of blood supply to ischemic myocardium. Well-developed coronary collateral arteries in patients with coronary artery disease (CAD) limit the size of acute myocardial infarction and improves survival. The aim of this study was to investigate the relationship between glycemic variability and coronary collateral formation in patients with type 2 diabetes mellitus and CAD. Consecutive patients undergoing percutaneous coronary intervention or coronary artery bypass grafting procedures were studied. Multivariate logistic regression models were used to examine the association between coronary artery collateral formation graded by Rentrope classification and glycemic variability, measured by coefficient variation of fasting blood glucose. In our study, we retrospectively enrolled 300 patients, of whom 239 were diabetic (age: 70.1±11.9, 56% men) and 61 were nondiabetic (age: 71.5±11.5, 72% men). Diabetic patients were further stratified as follows: those with poor coronary collateral artery development (n=171, age: 69.7±12.4, 55% men) and those with good coronary collateral artery development (n=68, age 71.1±10.8, 59% men) according to the Rentrope classification. Our findings did not show association between glycemic variability and coronary collateral vessels development after controlling for potential confounders (odds ratio: 2.51; 95% confidence interval: 0.57-11.03; P=0.22). The culprit lesion (≥75% stenosis) in the left anterior descending artery and the right coronary artery was more frequent in the good collateral group compared with the poor collateral group (66 vs. 50%, P=0.02; 63 vs. 45%, P=0.01 respectively). Glycemic variability is not associated with coronary collateral artery formation in patients with type 2 diabetes mellitus and CAD.

  4. Combined exercise reduces arterial stiffness, blood pressure, and blood markers for cardiovascular risk in postmenopausal women with hypertension.

    Science.gov (United States)

    Son, Won-Mok; Sung, Ki-Dong; Cho, Jae-Min; Park, Song-Young

    2017-03-01

    Postmenopausal women exhibit elevated brachial-ankle pulse wave velocity (baPWV), an indicator of arterial stiffness, which is associated with an increased risk of cardiovascular events and mortality. The purpose of this study is to examine the impact of combined resistance and aerobic exercise training on baPWV, blood pressure (BP), and cardiovascular fitness in postmenopausal women with stage 1 hypertension. Twenty postmenopausal women (age, 75 ± 2 y; systolic BP, 152 ± 2 mm Hg, diastolic BP, 95 ± 3 mm Hg) were randomly assigned to a "no-exercise" (CON, n = 10) or combined exercise (EX, n = 10) group. The EX group performed resistance and aerobic exercise for 12 weeks, 3 times per week. Exercise intensity was increased gradually, from 40% to 70% of heart rate reserve, every 4 weeks. BaPWV, BP, blood nitrite/nitrate, endothelin-1 (ET-1), cardiovascular fitness, and body composition were measured before and after the 12-week intervention. BP, baPWV (-1.2 ± 0.4 m/s), ET-1 (-2.7 ± 0.3 μmol/mL), nitrite/nitrate (+4.5 ± 0.5 μM), functional capacity, and body composition were significantly improved (P exercise training improves arterial stiffness, BP, ET-1, blood nitrite/nitrate, functional capacity, and body composition in postmenopausal women with stage 1 hypertension. Thus, this study provides evidence that combined exercise training is a useful therapeutic method to improve cardiovascular health which can reduce cardiovascular disease risk in postmenopausal women with hypertension.

  5. The cerebral arterial circle (circulus arteriosus cerebri): an anatomical study in fetus and infant samples.

    Science.gov (United States)

    Ardakani, Shahab Kamali; Dadmehr, Majid; Nejat, Farideh; Ansari, Saeed; Eftekhar, Behzad; Tajik, Parvin; El Khashab, Mostafa; Yazdani, Shahrooz; Ghodsi, Mohammad; Mahjoub, Fatemeh; Monajemzadeh, Maryam; Nazparvar, Bashir; Abdi-Rad, Afshin

    2008-01-01

    Many studies have investigated the variations in the anatomy of each segment of the cerebral arterial circle while a few have addressed the variations of the cerebral arterial circle as a whole. Thirty brains of recently deceased Iranian infants and fetuses were dissected. The dissection process was filmed and digitized so as to be readily available for further studies. The variations of the circle as a whole and segmental variations were evaluated. Variants with uni- and bilateral hypoplasia of posterior communicating arteries (PcoAs) were the most common in our study, similar to previous works. No aplasia of the precommunicating part of the anterior cerebral artery (A1), the precommunicating part of the posterior cerebral artery (P1) and anterior communicating artery was seen. Hypoplasia of the right and left PcoA was observed in 8 and 5 cases, respectively. Aplasia of the right PcoA was found in 16.6% and of the left PcoA in 3.3%. In this study, we confirmed the previously described finding that the symmetrical, circular configuration of the circulus arteriosus cerebri is present in only about 42.1%. The main differences between the fetal and adult disposition are the diameter of the PcoA and the circular part of the posterior cerebral artery. According to previous studies, the fetal brain older than 4 months has anatomical characteristics very similar to the adult's circle; our finding was mostly similar to adult samples as most samples were from infants, not fetuses. (c) 2008 S. Karger AG, Basel.

  6. MR velocity mapping measurement of renal artery blood flow in patients with impaired kidney function

    DEFF Research Database (Denmark)

    Cortsen, M; Petersen, L.J.; Stahlberg, F

    1996-01-01

    Renal blood flow (RBF) was measured in 9 patients with chronic impaired kidney function using MR velocity mapping and compared to PAH clearance and 99mTc-DTPA scintigraphy. An image plane suitable for flow measurement perpendicular to the renal arteries was chosen from 2-dimensional MR angiography....... MR velocity mapping was performed in both renal arteries using an ECG-triggered gradient echo pulse sequence previously validated in normal volunteers. Effective renal plasma flow was calculated from the clearance rate of PAH during constant infusion and the split of renal function was evaluated...... by 99mTc-DTPA scintigraphy. A reduction of RBF was found, and there was a significant correlation between PAH clearance multiplied by 1/(1-hematocrit) and RBF determined by MR velocity mapping. Furthermore, a significant correlation between the distribution of renal function and the percent distribution...

  7. Relationship between haemodynamic impairment and collateral blood flow in carotid artery disease

    DEFF Research Database (Denmark)

    Hartkamp, Nolan S; Petersen, Esben T; Chappell, Michael A

    2018-01-01

    Collateral blood flow plays a pivotal role in steno-occlusive internal carotid artery (ICA) disease to prevent irreversible ischaemic damage. Our aim was to investigate the effect of carotid artery disease upon cerebral perfusion and cerebrovascular reactivity and whether haemodynamic impairment...... is influenced at brain tissue level by the existence of primary and/or secondary collateral. Eighty-eight patients with steno-occlusive ICA disease and 29 healthy controls underwent MR examination. The presence of collaterals was determined with time-of-flight, two-dimensional phase contrast MRA and territorial....... In conclusion, both CBF and cerebrovascular reactivity were found to be reduced in symptomatic patients with steno-occlusive ICA disease. The presence of collateral flow is associated with further haemodynamic impairment. Recruitment of secondary collaterals is associated with severe haemodynamic impairment....

  8. [DNA quantification of blood samples pre-treated with pyramidon].

    Science.gov (United States)

    Zhu, Chuan-Hong; Zheng, Dao-Li; Ni, Rao-Zhi; Wang, Hai-Sheng; Ning, Ping; Fang, Hui; Liu, Yan

    2014-06-01

    To study DNA quantification and STR typing of samples pre-treated with pyramidon. The blood samples of ten unrelated individuals were anticoagulated in EDTA. The blood stains were made on the filter paper. The experimental groups were divided into six groups in accordance with the storage time, 30 min, 1 h, 3 h, 6 h, 12 h and 24h after pre-treated with pyramidon. DNA was extracted by three methods: magnetic bead-based extraction, QIAcube DNA purification method and Chelex-100 method. The quantification of DNA was made by fluorescent quantitative PCR. STR typing was detected by PCR-STR fluorescent technology. In the same DNA extraction method, the sample DNA decreased gradually with times after pre-treatment with pyramidon. In the same storage time, the DNA quantification in different extraction methods had significant differences. Sixteen loci DNA typing were detected in 90.56% of samples. Pyramidon pre-treatment could cause DNA degradation, but effective STR typing can be achieved within 24 h. The magnetic bead-based extraction is the best method for STR profiling and DNA extraction.

  9. Quantitative changes in the arterial blood gases of mice following localized irradiation of the lungs

    International Nuclear Information System (INIS)

    Siemann, D.W.; Hill, R.P.

    1983-01-01

    The arterial pH and partial pressures of oxygen (PaO 2 ) and carbon dioxide (PaCO 2 ) were evaluated in LAF1 mice 15 and 38 weeks after localized irradiation of the animals' thoraxes. Graded radiation doses of 900 to 1200 rad were administered. These doses resulted in 0 to 100% lethality by 26 weeks (180 days) after irradiation. At 15 weeks after treatment mice receiving radiation doses which would subsequently result in lethality (by 180 days) exhibited significant reductions in their PaO 2 and elevations in their PaCO 2 values, respectively. However, there was no clear dose-response relationship between blood gas values and radiation dose, which may reflect the animals' ability to compensate for their poor blood gas exchange by an increased breathing frequency. At 38 weeks after irradiation the blood gas values were abnormal in mice from groups which had normal blood gas values at Week 15 (and no fatalities by Week 26) but in which animal deaths had occurred between Weeks 26 and 38. These data therfore indicated (i) that abnormal blood gas values occurred in the mice prior to fatalities resulting from the acute radiation pneumonitis syndrome and (ii) that mice surviving the initial radiation pneumonitis phase could still succumb to progressive pulmonary toxicity which was reflected by the increasing levels of animal lethality and altered blood gas tensions at the later times

  10. [Clinical research of minimal extracorporeal circulation in perioperative blood conservation of coronary artery bypass graft].

    Science.gov (United States)

    Liu, Yan; Cui, Hu-jun; Tao, Liang; Chen, Xu-fa

    2011-04-01

    To analyze the clinical effect of minimal extracorporeal circulation (MECC) in blood conservation perioperatively coronary artery bypass graft (CABG). The data of 120 cases received simple CABG since August 2006 to October 2009 was analyzed retrospectively. All the patients were divided to three groups according to the mode of circulation support in-operation: MECC, conventional extracorporeal circulation (cECC) or off-pump, 40 cases in each group. Jostra MECC system with normal temperature was used in MECC group, and common membrane oxygenator with moderate hypo-temperature was used in cECC group. Collect the data of coagulation and the blood cytological examination perioperatively, the draining volume during the first 24 h after operation, and consumption of blood products perioperatively. Standard and logistic EuroSCORE were higher in MECC group than the others (P blood products in cECC group, but no difference among the three groups. MECC could reduce the ruin to blood cell and interfere to coagulation function during the conventional ECC procedure, decrease the postoperative draining volume and requirement of blood products.

  11. Effect of prewarming the forearm on the measurement of regional cerebral blood flow with one-point venous sampling by autoradiography method

    International Nuclear Information System (INIS)

    Itoh, Youko H.; Kurabe, Teruhisa; Kazaoka, Yoshiaki; Ishiguchi, Tsuneo; Kawashima, Sadao

    2004-01-01

    Autoradiography (ARG) using 123 I-iodoamphetamine ( 123 I-IMP) is widely performed as an efficient method of measuring local cerebral blood flow. Recently, ARG by a single collection of venous blood has been appreciated as a simple method. In this study, we investigated the effect of warming of the site for collecting venous blood (forearm). The coefficient of correlation of the local cerebral blood flow value obtained from arterial and venous blood samples was 0.766 (p<0.05) in the group without warming (38 patients). The coefficient of correlation similarly obtained in the group with warming (53 patients) was 0.908 (p<0.05). The difference in the correlation efficient was significant (p<0.05) between the two groups. From these results it was concluded that warming the blood-collecting site decreased the difference between the arterial and venous radioactive concentrations and increased the precision of the test. (author)

  12. Intravenous digital subtraction angiography for the evaluation of renal artery blood flow following the removal of a neuroblastoma

    International Nuclear Information System (INIS)

    Yamagiwa, Iwao; Obata, Kazuya; Saito, Hiroyuki; Washio, Masahiko

    1994-01-01

    There have been several reports of acute renal failure following the resection of an abdominal neuroblastoma combined with ipsilateral nephrectomy as well as the atrophy or disappearance of an unresected kidney after tumor resection. Spasms or thrombosis of the renal artery during tumor excision are considered to be the major cause. Since 1989, intravenous digital subtraction angiography (IVDSA) has been used to evaluate the renal artery blood flow immediately following surgery in seven patients with abdominal neuroblastomas. IVDSA was performed using a central venous catheter inserted prior to surgery. In all seven patients, IVDSA provided clear images for the evaluation of renal artery blood flow. In one of the two patients whose kidneys briefly became cyanosed during tumor excision, IVDSA demonstrated an occlusion of the renal artery and prompt measures could be taken to reestablish the blood flow. No complications of IVDSA occurred in any of the seven patients. IVDSA using a central venous catheter was thus considered to be useful for evaluating the renal artery blood flow in patients with a suspected renal artery blood flow disturbance without any risk of complications, and this modality obviated the need for intraarterial angiography. (author)

  13. Heat stress redistributes blood flow in arteries of the brain during dynamic exercise.

    Science.gov (United States)

    Sato, Kohei; Oue, Anna; Yoneya, Marina; Sadamoto, Tomoko; Ogoh, Shigehiko

    2016-04-01

    We hypothesized that heat stress would decrease anterior and posterior cerebral blood flow (CBF) during exercise, and the reduction in anterior CBF would be partly associated with large increase in extracranial blood flow (BF). Nine subjects performed 40 min of semirecumbent cycling at 60% of the peak oxygen uptake in hot (35°C; Heat) and thermoneutral environments (25°C; Control). We evaluated BF and conductance (COND) in the external carotid artery (ECA), internal carotid artery (ICA), and vertebral artery (VA) using ultrasonography. During the Heat condition, ICA and VA BF were significantly increased 10 min after the start of exercise (P Heat. Compared with the Control, either BF or COND of ICA and VA at the end of Heat tended to be lower, but not significantly. In contrast, ECA BF and COND at the end of Heat were both higher than levels in the Control condition (P Heat, a reduction in ICA BF appears to be associated with a decline in end-tidal CO2 tension (r = 0.84), whereas VA BF appears to be affected by a change in cardiac output (r = 0.87). In addition, a change in ECA BF during Heat was negatively correlated with a change in ICA BF (r = -0.75). Heat stress resulted in modification of the vascular response of head and brain arteries to exercise, which resulted in an alteration in the distribution of cardiac output. Moreover, a hyperthermia-induced increase in extracranial BF might compromise anterior CBF during exercise with heat stress. Copyright © 2016 the American Physiological Society.

  14. Impaired increase of retinal capillary blood flow to flicker light exposure in arterial hypertension.

    Science.gov (United States)

    Ritt, Martin; Harazny, Joanna M; Ott, Christian; Raff, Ulrike; Bauernschubert, Philipp; Lehmann, Marina; Michelson, Georg; Schmieder, Roland E

    2012-09-01

    We hypothesized that the increase of retinal capillary blood flow (RCF) to flicker light exposure is impaired in subjects with arterial hypertension. In 146 nondiabetic untreated male subjects with (n=50) or without (n=96) arterial hypertension, RCF was measured before and after flicker light exposure noninvasively and in vivo using scanning laser Doppler flowmetry. In addition, in a subgroup of 28 subjects, the change of RCF to flicker light exposure was again assessed during parallel infusion of nitric oxide synthase inhibitor N-monomethyl-L-arginine (L-NMMA). The increase of RCF to flicker light exposure was lower in patients with untreated hypertension compared with normotensive subjects when expressed in absolute terms (7.69±54 versus 27.2±44 AU; P adjusted=0.013) or percent changes (2.95±14 versus 8.33±12%; P adjusted=0.023). Systolic (β=-0.216; P=0.023) but not diastolic blood pressure (β=-0.117; P=0.243) or mean arterial pressure (β=-0.178; P=0.073) was negatively related to the percent change of RCF to flicker light exposure, independently of other cardiovascular risk factors. In the subgroup of 28 subjects, the increase of RCF to flicker light exposure was similar at baseline and during parallel infusion of L-NMMA when expressed in absolute terms (20.0±51 versus 22.6±56 AU; P=0.731) or percent changes (7.12±16 versus 8.29±18%; P=0.607). The increase of RCF to flicker light exposure is impaired in arterial hypertension. In the subgroup of the total study cohort, nitric oxide was not a major determinant of the increase of RCF to flicker light exposure.

  15. Effects of a nitrate-rich meal on arterial stiffness and blood pressure in healthy volunteers.

    Science.gov (United States)

    Liu, Alex H; Bondonno, Catherine P; Croft, Kevin D; Puddey, Ian B; Woodman, Richard J; Rich, Lisa; Ward, Natalie C; Vita, Joseph A; Hodgson, Jonathan M

    2013-11-30

    An increase in nitrate intake can augment circulating nitrite and nitric oxide. This may lead to lower blood pressure and improved vascular function. Green leafy vegetables, such as spinach, are rich sources of nitrate. We aimed to assess the acute effects of a nitrate-rich meal containing spinach on arterial stiffness and blood pressure in healthy men and women. Twenty-six participants aged 38-69years were recruited to a randomized controlled cross-over trial. The acute effects of two energy-matched (2000kJ) meals, administered in random order, were compared. The meals were either high nitrate (220mg of nitrate derived from spinach [spinach]) or low nitrate [control]. Outcome measurements were performed pre-meal and at specific time points up to 210min post meal. Spinach resulted in an eightfold increase in salivary nitrite and a sevenfold increase in salivary nitrate concentrations from pre-meal (Pnitrate-rich meal can lower systolic blood pressure and pulse pressure and increase large artery compliance acutely in healthy men and women. If sustained, these effects could contribute to better cardiovascular health. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Noninvasive estimation of pulmonary arterial pressure by analysis of pulmonary blood-flow distribution

    International Nuclear Information System (INIS)

    Konstam, M.A.; Strauss, H.W.; Alpert, N.M.; Miller, S.W.; Murphy, R.X.; Greene, R.E.; McKusick, K.A.

    1979-01-01

    To determine whether a correlation exists between pulmonary arterial (PA) pressure (P/sub a/) and the distribution of pulmonary blood flow, this distribution was measured in four upright dogs in the control state and during intravenous infusions of epinephrine or prostaglandin F/sub 2α/. During suspension of respiration, 15 mCi of Xe-133 were injected intravenously, and perfusion and equilibration lung images were recorded with a scintillation camera. The procedure was performed several times on each dog, with and without pharmacological elevation of PA pressure by 5 to 50 cm H 2 O. For each scintigram, the relative blood flow per unit ventilated lung volume (F) was plotted against centimeters above the hilum (h). Pulmonary arterial pressure was derived from each curve, assuming the relation F = B(P/sub a/ - hD) 2 , where B = constant and D = specific gravity of blood. Calculated PA pressure correlated strongly (r = 0.83) with measured PA pressure, suggesting a possible means of noninvasive estimation of PA pressure

  17. DOES TRANEXAMIC ACID REDUCE BLOOD LOSS IN OFF-PUMP CORONARY ARTERY BYPASS?

    Directory of Open Access Journals (Sweden)

    A. Mehr-Aein

    2006-09-01

    Full Text Available Tranexamic acid is now used on a routine basis for on-pump coronary artery bypass grafting (CABG. We assessed the hemostatic effects of tranexamic acid to decrease bleeding tendency and transfusion requirements in patients undergoing off-pump coronary artery bypass surgery (OPCAB. A total of 66 patients were enrolled to elective OPCAB in a double-blind, prospective randomized study. Of these, 33 patients received tranexamic acid (15 mg/kg before the infusion of heparin and 15 mg/kg after protamin infusion, and 33 patients received only saline. Preoperative hematologic variables, postoperative bleeding and allogeneic transfusions were considered. D-dimer plasma levels were also evaluated to monitor the activation of fibrinolysis. Postoperative bleeding was significantly lower in the tranexamic acid group compared with the control group (320 ± 38 mL vs. 480 ± 75 mL at 12 hour, P < 0.001. The tranexamic acid group had significantly lesser need for allogeneic blood products (0.46 units/patients vs. 0.94 units/patients, P < 0.001. They had also lower post-operative D-dimer plasma levels. No postoperative thrombotic complications were observed in either group. The defective hemostasis occurs even in the OPCABG. Tranexamic acid effectively reduces postoperative blood loss and the need for allogeneic blood products after OPCAB is decreased.

  18. An efficient parallel simulation of unsteady blood flows in patient-specific pulmonary artery.

    Science.gov (United States)

    Kong, Fande; Kheyfets, Vitaly; Finol, Ender; Cai, Xiao-Chuan

    2018-04-01

    Simulation of blood flows in the pulmonary artery provides some insight into certain diseases by examining the relationship between some continuum metrics, eg, the wall shear stress acting on the vascular endothelium, which responds to flow-induced mechanical forces by releasing vasodilators/constrictors. V. Kheyfets, in his previous work, studies numerically a patient-specific pulmonary circulation to show that decreasing wall shear stress is correlated with increasing pulmonary vascular impedance. In this paper, we develop a scalable parallel algorithm based on domain decomposition methods to investigate an unsteady model with patient-specific pulsatile waveforms as the inlet boundary condition. The unsteady model offers tremendously more information about the dynamic behavior of the flow field, but computationally speaking, the simulation is a lot more expensive since a problem which is similar to the steady-state problem has to be solved many times, and therefore, the traditional sequential approach is not suitable anymore. We show computationally that simulations using the proposed parallel approach with up to 10 000 processor cores can be obtained with much reduced compute time. This makes the technology potentially usable for the routine study of the dynamic behavior of blood flows in the pulmonary artery, in particular, the changes of the blood flows and the wall shear stress in the spatial and temporal dimensions. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Evaluation of MR angiography and blood flow measurement in abdominal and peripheral arterial occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Tabuchi, Kenji [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    To assess the characteristics of blood flow measurement with MR Angiography (MRA) to evaluate the status of vascular stenoses, two or three dimensional time-of-flight MRA and velocity-encoded cine MR were performed in the 230 segments of 35 patients, with abdominal and peripheral arterial occlusive diseases. In 11 of these 35 patients digital subtraction angiography was additionally underwent, and the stenotic findings was compared with MRA. There were 17 segments in which the velocity could not be measured, because the blood flow exceeded the upper limit of peak-encoded velocity (VENC) which was set at 120 cm/sec. Therefore, it is necessary to set the upper limit of VENC at higher than 120 cm/sec. There were 11 stenotic findings in DSA and 20 stenotic findings in MRA. Pulsatility Index (PI=(max velocity-min. velocity)/average velocity) were used for evaluating the blood flow waveform, and there were significant difference between the 11 stenotic findings of DSA and the others'. In summery, MRA was considered as useful examination to assess the degree of the vascular stenoses in abdominal and peripheral arterial occlusive disease. (author)

  20. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    International Nuclear Information System (INIS)

    Cao Wei; Li Jing; Wu Zhiqun; Zhou Changxi; Liu Xi; Wan Yi; Duan Yunyou

    2013-01-01

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 °C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 °C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  1. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Cao Wei, E-mail: cawe-001@163.com [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Li Jing, E-mail: lijing02@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Burn and Plastic Surgery (China); Wu Zhiqun, E-mail: zhiqunwu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Zhou Changxi, E-mail: changxizhou@163.com [Chinese PLA General Hospital, Department of Respiratory Disease (China); Liu Xi, E-mail: xiliu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China); Wan Yi, E-mail: yiwan@163.com [The Fourth Military Medical University, Department of Health Statistics, Institute for Health Informatics (China); Duan Yunyou, E-mail: yunyouduan@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China)

    2013-06-15

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 Degree-Sign C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 Degree-Sign C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  2. Pelvic magnetic resonance imaging angioanatomy of the arterial blood supply to the penis in suspected prostate cancer patients

    International Nuclear Information System (INIS)

    Thai, Cao Tan; Karam, Ibrahim Michel; Nguyen-Thi, Phi Linh; Lefèvre, Frédéric; Hubert, Jacques; Felblinger, Jacques; Eschwège, Pascal

    2015-01-01

    Highlights: • Three patterns of penile arterial supply (according to the classification of Stéphane Droupy). • Our classification about accessory pudendal artery. • Origin of accessory pudendal artery. - Abstract: Purpose: To describe the internal pudendal artery (IPA) and accessory pudendal artery (APA) detected by magnetic resonance (MR) angiography to help surgeons to find and preserve them during radical prostatectomy (RP). Materials and methods: Constrast-enhanced MR 3.0 T angiography of the pelvis were performed in 111 male patients suspected diagnosis of prostate cancer (PCa), and describe the penile arterial blood supply. Results: There are three patterns of the arterial blood supply to the penis (IPA and/or APA) accounting for 51.4%, 46.8% and 1.8% of cases, respectively. About the accessory pudendal artery (APA): 54/111 (48.6%) patients had APA with five different branching patterns, they were type I (APA bilateral symmetry): 17 (31.5%); type II (APA bilateral asymmetry): 1 (1.9%); type III (APA unilateral lateral): 13 (24%); type IV (APA unilateral apical): 21 (38.9%); type V (APA unilateral mix): 2 (3.7%). APA origin were from inferior epigastric artery (IEA): 7 (9.5%); from inferior vesical artery (IVA): 32 (43.2%); from obturator artery (OA): 35 (47.3%). Conclusion: A precise angioanatomic evalutation of arteries destined to the penis by MR angiography pre-operation for male pelvic organs will help surgeons to preserve them and contributes to reduce the erectile dysfunction after these procedures

  3. Pelvic magnetic resonance imaging angioanatomy of the arterial blood supply to the penis in suspected prostate cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Thai, Cao Tan, E-mail: bstanhatinh@gmail.com [Department of Urology, Brabois Hospital, University Hospital of Nancy, Rue du Morvan, 54500 Vandoeuvre Lès Nancy Cedex (France); IADI Laboratory, INSERM-U947, Brabois Hospital, University Hospital of Nancy, Tour Drouet, rue du Morvan, 54511 Vandoeuvre Lès Nancy Cedex (France); Karam, Ibrahim Michel [Clinical Epidemiology and Evaluation Department, University Hospital of Nancy (France); Department of Anatomy, Faculty of Medicine Nancy, 9 Avenue de la Foret de haye BP, 54505 Vandoeuvre Lès Nancy Cedex (France); Nguyen-Thi, Phi Linh [Clinical Epidemiology and Evaluation Department, University Hospital of Nancy (France); INSERM, CIC-EC CIE6, 92 Avenue du Maréchal de Lattre de Tassigny, 54000 Nancy (France); Lefèvre, Frédéric [Department of Radiology, Brabois Hospital, University Hospital of Nancy, Rue du Morvan, 54500 Vandoeuvre Lès Nancy Cedex (France); Hubert, Jacques [Department of Urology, Brabois Hospital, University Hospital of Nancy, Rue du Morvan, 54500 Vandoeuvre Lès Nancy Cedex (France); IADI Laboratory, INSERM-U947, Brabois Hospital, University Hospital of Nancy, Tour Drouet, rue du Morvan, 54511 Vandoeuvre Lès Nancy Cedex (France); Felblinger, Jacques [IADI Laboratory, INSERM-U947, Brabois Hospital, University Hospital of Nancy, Tour Drouet, rue du Morvan, 54511 Vandoeuvre Lès Nancy Cedex (France); Eschwège, Pascal [Department of Urology, Brabois Hospital, University Hospital of Nancy, Rue du Morvan, 54500 Vandoeuvre Lès Nancy Cedex (France)

    2015-05-15

    Highlights: • Three patterns of penile arterial supply (according to the classification of Stéphane Droupy). • Our classification about accessory pudendal artery. • Origin of accessory pudendal artery. - Abstract: Purpose: To describe the internal pudendal artery (IPA) and accessory pudendal artery (APA) detected by magnetic resonance (MR) angiography to help surgeons to find and preserve them during radical prostatectomy (RP). Materials and methods: Constrast-enhanced MR 3.0 T angiography of the pelvis were performed in 111 male patients suspected diagnosis of prostate cancer (PCa), and describe the penile arterial blood supply. Results: There are three patterns of the arterial blood supply to the penis (IPA and/or APA) accounting for 51.4%, 46.8% and 1.8% of cases, respectively. About the accessory pudendal artery (APA): 54/111 (48.6%) patients had APA with five different branching patterns, they were type I (APA bilateral symmetry): 17 (31.5%); type II (APA bilateral asymmetry): 1 (1.9%); type III (APA unilateral lateral): 13 (24%); type IV (APA unilateral apical): 21 (38.9%); type V (APA unilateral mix): 2 (3.7%). APA origin were from inferior epigastric artery (IEA): 7 (9.5%); from inferior vesical artery (IVA): 32 (43.2%); from obturator artery (OA): 35 (47.3%). Conclusion: A precise angioanatomic evalutation of arteries destined to the penis by MR angiography pre-operation for male pelvic organs will help surgeons to preserve them and contributes to reduce the erectile dysfunction after these procedures.

  4. Increases in arterial blood oxygen during exercise in the lemon shark (Negaprion brevirostris)

    DEFF Research Database (Denmark)

    BUSHNELL, PG; LUTZ, PL; STEFFENSEN, JF

    1982-01-01

    Polyethylene cannulae were implanted in pre- and post-branchial blood vessels allowing nonstressful blood sampling over a variety of activity ranges in an active tropical elasmobranch, the lemon shark (Negaprion brevirostris). TheP 50 was found to be 11.8 Torr at 24°C and pH of 7.7. A Bohr shift...

  5. Improved arterial blood oxygenation following intravenous infusion of cold supersaturated dissolved oxygen solution.

    Science.gov (United States)

    Grady, Daniel J; Gentile, Michael A; Riggs, John H; Cheifetz, Ira M

    2014-01-01

    One of the primary goals of critical care medicine is to support adequate gas exchange without iatrogenic sequelae. An emerging method of delivering supplemental oxygen is intravenously rather than via the traditional inhalation route. The objective of this study was to evaluate the gas-exchange effects of infusing cold intravenous (IV) fluids containing very high partial pressures of dissolved oxygen (>760 mm Hg) in a porcine model. Juvenile swines were anesthetized and mechanically ventilated. Each animal received an infusion of cold (13 °C) Ringer's lactate solution (30 mL/kg/hour), which had been supersaturated with dissolved oxygen gas (39.7 mg/L dissolved oxygen, 992 mm Hg, 30.5 mL/L). Arterial blood gases and physiologic measurements were repeated at 15-minute intervals during a 60-minute IV infusion of the supersaturated dissolved oxygen solution. Each animal served as its own control. Five swines (12.9 ± 0.9 kg) were studied. Following the 60-minute infusion, there were significant increases in PaO2 and SaO2 (P < 0.05) and a significant decrease in PaCO2 (P < 0.05), with a corresponding normalization in arterial blood pH. Additionally, there was a significant decrease in core body temperature (P < 0.05) when compared to the baseline preinfusion state. A cold, supersaturated dissolved oxygen solution may be intravenously administered to improve arterial blood oxygenation and ventilation parameters and induce a mild therapeutic hypothermia in a porcine model.

  6. Influence of hemodialysis on the mean blood flow velocity in the middle cerebral artery.

    Science.gov (United States)

    Stefanidis, I; Bach, R; Mertens, P R; Liakopoulos, V; Liapi, G; Mann, H; Heintz, B

    2005-08-01

    Several effects of hemodialysis, including hemoconcentration, alterations of hemostasis or hemorheology and endothelial activation, could potentially interfere with cerebral blood flow (CBF) regulation. These treatment-specific changes may also be crucial for the enhanced incidence of stroke in uremic patients. Nevertheless, the influence of hemodialysis on CBF has not been yet adequately studied. We registered mean blood flow velocity (MFV) in the middle cerebral artery (MCA) during hemodialysis treatment in order to evaluate its contribution on CBF changes. Transcranial Doppler ultrasonography (TCD) of the MCA was performed continuously during hemodialysis treatment in 18 stable patients (10 males and 8 females, mean age 62 +/- 11 years) with end-stage renal disease of various origin. Blood pressure (mmHg), heart rate (/min), ultrafiltration volume (ml), BV changes (deltaBV by hemoglobinometry, %), arterial blood gases (pO2, blood oxygen content, pCO2), hemostasis activation (thrombin-antithrombin III complex, ELISA) and fibrinogen (Clauss) were measured simultaneously at the beginning of treatment and every hour thereafter. Before the hemodialysis session the MFV in the MCA was within normal range (57.5 +/- 13.0 cm/s, ref. 60 +/- 12) and was mainly dependent on the patients' age (r = -0.697, p delta%MFV) were interrelated to the ultrafiltration volume (r = -0.486, p delta%acO2, r = -0.420, p delta%fibrinogen, r = 0.244, p < 0.05). A significant continuous decrease of the MFV in the MCA was observed during hemodialysis treatment, which inversely correlated both with ultrafiltration volume, BV changes and changes of plasma fibrinogen. The ultrafiltration-induced hemoconcentration with concomitant rise of hematocrit and oxygen transport capacity, may partly explain the alterations in the cerebral MFV observed during hemodialysis.

  7. Blood transfusion sampling and a greater role for error recovery.

    Science.gov (United States)

    Oldham, Jane

    Patient identification errors in pre-transfusion blood sampling ('wrong blood in tube') are a persistent area of risk. These errors can potentially result in life-threatening complications. Current measures to address root causes of incidents and near misses have not resolved this problem and there is a need to look afresh at this issue. PROJECT PURPOSE: This narrative review of the literature is part of a wider system-improvement project designed to explore and seek a better understanding of the factors that contribute to transfusion sampling error as a prerequisite to examining current and potential approaches to error reduction. A broad search of the literature was undertaken to identify themes relating to this phenomenon. KEY DISCOVERIES: Two key themes emerged from the literature. Firstly, despite multi-faceted causes of error, the consistent element is the ever-present potential for human error. Secondly, current focus on error prevention could potentially be augmented with greater attention to error recovery. Exploring ways in which clinical staff taking samples might learn how to better identify their own errors is proposed to add to current safety initiatives.

  8. Sex identification of polar bears from blood and tissue samples

    Science.gov (United States)

    Amstrup, Steven C.; Garner, G.W.; Cronin, M.A.; Patton, J.C.

    1993-01-01

    Polar bears (Ursus maritimus) can be adversely affected by hunting and other human perturbations because of low population densities and low reproduction rates. The sustainable take of adult females may be as low as 1.5% of the population. Females and accompanying young are most vulnerable to hunting, and hunters have not consistently reported the sex composition of the harvest, therefore a method to confirm the sexes of polar bears harvested in Alaska is needed. Evidence of the sex of harvested animals is often not available, but blood or other tissue samples often are. We extracted DNA from tissue and blood samples, and amplified segments of zinc finger (ZFX and ZFY) genes from both X and Y chromosomes with the polymerase chain reaction. Digestion of amplified portions of the X chromosome with the restriction enzyme HaeIII resulted in subdivision of the original amplified segment into four smaller fragments. Digestion with HaeIII did not subdivide the original segment amplified from the Y chromosome. The differing fragment sizes produced patterns in gel electrophoresis that distinguished samples from male and female bears 100% of the time. This technique is applicable to the investigation of many wildlife management and research questions.

  9. High plasma corticosterone levels persist during frequent automatic blood sampling in rats

    DEFF Research Database (Denmark)

    Abelson, Klas S P; Adem, Bashir; Royo, Felix

    2005-01-01

    Corticosterone levels in blood may be used as a marker of stress in rodents, provided that the blood sampling procedure itself is non-stressful. Automated blood sampling equipment (Accusampler) allows blood sampling without any interference with the animal and might be useful as a tool for an on......-line measurement of stress markers in blood. However, the impact of the blood sampling itself on the corticosterone levels in blood is unknown. The present study was designed to evaluate whether the frequency of blood sampling influences the plasma corticosterone levels in male and female rats. During anaesthesia...... the importance of considering the frequency of blood withdrawal during automated blood sampling. This parameter may have an impact on the experimental results when using blood corticosterone levels as a stress marker, but also during any in vivo study where blood is collected, since high corticosterone levels...

  10. Renal blood flow after selective injection of different dosages of diatrizoate into the renal artery

    International Nuclear Information System (INIS)

    Burgener, F.A.; Fischer, H.W.; Weber, D.A.

    1975-01-01

    The characteristic biphasic renal haemodynamic response to diatrizoate injected into the renal artery was shown in the dog with the 133-xenon washout technique. A brief increase in renal blood flow (RBF) during the first ten seconds is followed by a more prolonged period of diminuished RBF. A dose of 4 ml. diatrizoate 60% resulted in the maximum RBF increase of 43% after ten seconds, but even 1 ml. diatrizoate raised the RBF 24%. The initial vasodilator effect of diatrizoate compares well in its extent with the most potent renal vasodilators. (orig.) [de

  11. [Prehospital arterial blood gas analysis after collapse connected to triathlon participation].

    Science.gov (United States)

    Ettrup-Christensen, Asbjørn; Amstrup-Hansen, Louise; Zwisler, Stine T

    2017-05-01

    Long-distance athletes are at risk of serious fluid and electrolyte disturbances, such as hypernatraemia (dehydration). Recently, cases of serious morbidity have been reported, due to acute exercise-associated hyponatraemia, which can advance to encephalopathy. An arterial blood gas analysis (ABG) was drawn from collapsed athletes at the championship of full-distance triathlon 2015, and different electrolyte imbalances were found. Our findings show that prehospital ABG can assist in differentiating the cause of collapse, and presumably, targeted treatment can be initiated already on scene.

  12. Renal blood flow, diuresis and isotope nephrogram in experimental stenosis of the renal artery

    International Nuclear Information System (INIS)

    Pemsel, H.K.; Lange, H.; Mahlstedt, J.; Joseph, K.; Marburg Univ.; Marburg Univ.

    1979-01-01

    After experimental stenosis of the renal artery of the dog, the isotope nephrogram shows a prolongation of the transit-time, when the renal blood flow is reduced to 40-70%. This finding was most significant in low diuresis (0,05-0,2 ml/min), sporadic in moderate diuresis (0,2-2,0 ml/min), no longer demonstrable in forced diuresis (>2,0 ml/min). The diuretic effect of X-ray contrast-medium (70% Na-Meglumin-Jotalamat, 0,5 ml/kg i.v.) normalizes a pathologic ING in low diuresis. (orig.) [de

  13. Arterial Spin Labeling and Blood Oxygen Level-Dependent MRI Cerebrovascular Reactivity in Cerebrovascular Disease

    DEFF Research Database (Denmark)

    Smeeing, Diederik P J; Hendrikse, Jeroen; Petersen, Esben T

    2016-01-01

    BACKGROUND: The cerebrovascular reactivity (CVR) results of blood oxygen level-dependent (BOLD) and arterial spin labeling (ASL) MRI studies performed in patients with cerebrovascular disease (steno-occlusive vascular disease or stroke) were systematically reviewed. SUMMARY: Thirty-one articles...... found a significant lower ASL CVR in the ipsilateral hemispheres of patients compared to controls. KEY MESSAGES: This review brings support for a reduced BOLD and ASL CVR in the ipsilateral hemisphere of patients with cerebrovascular disease. We suggest that future studies will be performed in a uniform...... way so reference values can be established and could be used to guide treatment decisions in patients with cerebrovascular disease....

  14. Fetal scalp blood sampling in labor - a review

    DEFF Research Database (Denmark)

    Jørgensen, Jan Stener; Weber, Tom

    2014-01-01

    During the 1970s and 1980s, electronic fetal monitoring and fetal scalp blood sampling (FBS) were introduced without robust evidence. With a methodical review of the published literature, and using one randomized controlled trial, seven controlled studies, nine randomized studies of various...... surveillance methods and data from the Danish National Birth Registry, we have assessed the usefulness of FBS as a complementary tool to improve the specificity and sensitivity of electronic cardiotocography (CTG). Based on heterogeneous studies of modest quality with somewhat inconsistent results, we conclude...

  15. Radioimmunoassay for determination of blood aldosterone and renin in the diagnosis of some forms of arterial hypertension

    International Nuclear Information System (INIS)

    Khamidov, R.I.; Khalmuratova, R.A.; Sattarova, F.K.

    1987-01-01

    Aldosterone concentration and renin activity in the blood from the ulnar, inferior cava veins at the level of the 12th thoracic vertebra, the left and right renal veins were studied in 60 patients with arterial hypertension by means of a radioimmunoassay kits (France). The patients were divided into 4 groups: with primary and idiopathic hyperaldosteronism, renal-parenchymatous and essential arterial hypertension. The diagnosis of primary and idiopathic hyperaldosteronism was also confirmed by low blood renin activity. Renin activity in the peripheral venous blood was considerably elevated in renal-parenchymatous arterial hypertension and was normal in essential hypertension. Aldosterone concentration in the blood from the vena cava inferior and renal veins was 1.6-2-fold as high on the affected side as on the contralateral one

  16. Arterial stick

    Science.gov (United States)

    ... be some throbbing. Why the Test Is Performed Blood transports oxygen, nutrients, waste products, and other materials within ... venous blood) mainly in its content of dissolved gases . Testing arterial blood shows the makeup of the blood before any ...

  17. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  18. L-Cysteine ethyl ester reverses the deleterious effects of morphine on, arterial blood-gas chemistry in tracheotomized rats.

    Science.gov (United States)

    Mendoza, James; Passafaro, Rachael; Baby, Santhosh; Young, Alex P; Bates, James N; Gaston, Benjamin; Lewis, Stephen J

    2013-10-01

    This study determined whether the membrane-permeable ventilatory stimulant, L-cysteine ethylester (L-CYSee), reversed the deleterious actions of morphine on arterial blood-gas chemistry in isoflurane-anesthetized rats. Morphine (2 mg/kg, i.v.) elicited sustained decreases in arterial blood pH, pO₂ and sO₂, and increases in pCO₂ (all responses indicative of hypoventilation) and alveolar-arterial gradient (indicative of ventilation-perfusion mismatch). Injections of L-CYSee (100 μmol/kg, i.v.) reversed the effects of morphine in tracheotomized rats but were minimally active in non-tracheotomized rats. L-cysteine or L-serine ethylester (100 μmol/kg, i.v.) were without effect. It is evident that L-CYSee can reverse the negative effects of morphine on arterial blood-gas chemistry and alveolar-arterial gradient but that this positive activity is negated by increases in upper-airway resistance. Since L-cysteine and L-serine ethylester were ineffective, it is evident that cell penetrability and the sulfur moiety of L-CYSee are essential for activity. Due to its ready penetrability into the lungs, chest wall muscle and brain, the effects of L-CYSee on morphine-induced changes in arterial blood-gas chemistry are likely to involve both central and peripheral sites of action. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Accuracy of Transcutaneous CO2 Values Compared With Arterial and Capillary Blood Gases.

    Science.gov (United States)

    Lambert, Laura L; Baldwin, Melissa B; Gonzalez, Cruz Velasco; Lowe, Gary R; Willis, J Randy

    2018-05-08

    Transcutaneous monitors are utilized to monitor a patient's respiratory status. Some patients have similar values when comparing transcutaneous carbon dioxide ( P tcCO 2 ) values with blood gas analysis, whereas others show extreme variability. A retrospective review of data was performed to determine how accurately P tcCO 2 correlated with CO 2 values obtained by arterial blood gas (ABG) or capillary blood gas. To determine whether P tcCO 2 values correlated with ABG or capillary blood gas values, subjects' records were retrospectively reviewed. Data collected included the P tcCO 2 value at the time of blood gas procurement and the ABG or capillary blood gas P CO 2 value. Agreement of pairs of methods (ABG vs P tcCO 2 and capillary blood gas vs P tcCO 2 ) was assessed with the Bland-Altman approach with limits of agreement estimated with a mixed model to account for serial measurements per subject. A total of 912 pairs of ABG/ P tcCO 2 values on 54 subjects and 307 pairs of capillary blood gas/ P tcCO 2 values on 34 subjects were analyzed. The P CO 2 range for ABG was 24-106 mm Hg, and P tcCO 2 values were 27-133 mm Hg. The P CO 2 range for capillary blood gas was 29-108 mm Hg, and P tcCO 2 values were 30-103 mm Hg. For ABG/ P tcCO 2 comparisons, the Pearson correlation coefficient was 0.82, 95% CI was 0.80-0.84, and P was <.001. For capillary blood gas/ P tcCO 2 comparisons, the Pearson correlation coefficient was 0.77, 95% CI was 0.72-0.81, and P was <.001. For ABG/ P tcCO 2 , the estimated difference ± SD was -6.79 t± 7.62 mm Hg, and limits of agreement were -22.03 to 8.45. For capillary blood gas/ P tcCO 2 , the estimated difference ± SD was -1.61 ± 7.64 mm Hg, and limits of agreement were -16.88 to 13.66. The repeatability coefficient was about 30 mm Hg. Based on these data, capillary blood gas comparisons showed less variation and a slightly lower correlation with P tcCO 2 than did ABG comparisons. After accounting for serial measurements per patient

  20. Trace-element measurement in human blood samples

    International Nuclear Information System (INIS)

    Hamidian, M.R.; Ebrahimi-Fakhar, F.

    1992-01-01

    It is conceivable that some essential elements such as zinc, iron, calcium, copper, phosphorus, selenium, etc., have a major impact on biological and metabolical functions in the human body. The concentration of these elements is normally very minute and changes within a naturally set tolerance. The accurate measurement of these elements in biological samples, such as in blood, is one of the objectives of medical physics in diagnosis. There are many sophisticated methods to measure the accurate amount of each element in biological samples. The methods used in this project are a combination of proton-induced X-ray emission (PIXE) and neutron activation analysis (NAA). The PIXE and NAA are fast and reliable techniques for multielement analysis at the level of parts per million and less

  1. Dynamic 2-[18F]fluoro-2-deoxy-d-glucose positron emission tomography of liver tumours without blood sampling

    International Nuclear Information System (INIS)

    Keiding, S.; Munk, O.L.; Schioett, K.M.; Hansen, S.B.

    2000-01-01

    Positron emission tomography (PET) using 2-[ 18 F]fluoro-2-deoxy-d-glucose (FDG) is a useful diagnostic tool for the detection of tumours. Using dynamic FDG PET, net metabolic clearance of FDG, K, can be calculated by Gjedde-Patlak analysis of the time course of the radioactivity concentrations in tissue and arterial blood. We examined whether time-activity curves (TACs) based on arterial blood sampling could be replaced by TACs obtained from the descending aorta in dynamic PET scans of patients with liver tumours. The study was performed in two parts, using data from dynamic liver scans with arterial blood sampling in human subjects: First, data from four patients with no liver tumours and five patients with liver tumours were used as a training group. Volumes of interest were defined in the descending aorta (aorta VOIs) by four different methods. K values were calculated based on the corresponding TACs and compared with those based on TACs of the arterial blood sample radioactivity concentrations. The aorta VOI which gave K values that were in best agreement with the K values based on the arterial blood sample measurements was called the AORTA-VOI. Use of the AORTA-VOI was subsequently tested in a test group of 19 tumour patients by comparing the K values from the AORTA-VOI with the K values based on the arterial blood sample measurements. The AORTA-VOI consisted of the sum of small regions of interest (ROIs) drawn in the centre of the aorta (approximately six pixels of 2.4 x 2.4 mm per transaxial slice of 3.1 mm thickness) in as many transaxial slices as possible (30-40 slices). There were no statistically significant differences between the two sets of K values. The ratio of K values in tumour tissue to K values in reference tissue was 2.1-9.7:1 (mean, 5.4:1) based on the AORTA TACs, and 2.1-8.4:1 (mean, 4.6:1) based on blood sample TACs (P>0.3). We conclude that arterial blood sampling can be replaced by the present AORTA-VOI in the calculation of the net

  2. Obese children and adolescents have elevated nighttime blood pressure independent of insulin resistance and arterial stiffness

    DEFF Research Database (Denmark)

    Hvidt, Kristian N; Olsen, Michael H; Holm, Jens-Christian

    2014-01-01

    BACKGROUND: Insulin resistance has been related to elevated blood pressure (BP) in obese children and may adversely affect the vasculature by arterial stiffening. The objective was to investigate whether daytime and nighttime BP were elevated and related to insulin resistance and arterial stiffness...... in obese children and adolescents. METHODS: Ninety-two obese patients aged 10-18 years were compared with 49 healthy control individuals. Insulin resistance was measured as the homeostatic assessment model (HOMA), and arterial stiffness was measured as carotid-femoral pulse wave velocity (cfPWV). RESULTS......: Mean ± SD daytime systolic BP (SBP) (obese: 125±8.3mm Hg; control: 121±10.1mm Hg; P = 0.03) and nighttime SBP (obese: 108±10.7mm Hg; control: 102±8.2mm Hg; P = 0.0001) were higher in the obese group when compared with the control group. No difference was found in daytime diastolic BP (DBP), whereas...

  3. Tobacco smoking strengthens the association of elevated blood pressure with arterial stiffness: the Bogalusa Heart Study.

    Science.gov (United States)

    Yun, Miaoying; Li, Shengxu; Sun, Dianjianyi; Ge, Shaoqing; Lai, Chin-Chih; Fernandez, Camilo; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S

    2015-02-01

    The study assessed the hypothesis that smoking strengthens the association of adult arterial stiffness with long-term cumulative burden of blood pressure (BP) from childhood to adulthood. Tobacco smoking and elevated BPs are important risk factors of vascular stiffness. However, the synergistic effect of these two risk factors is not well established, especially for the long-term burden of elevated BP since childhood. The study cohort consisted of 945 adults (661 whites and 284 blacks, aged 24-43 years) who have BP measured 4-15 times since childhood (aged 4-17 years) in Bogalusa, Louisiana. The adult arterial stiffness was measured as aorta-femoral pulse wave velocity (afPWV); the total area under the curve (AUC) and incremental AUC were used as a measure of long-term burden and trends of BP, respectively. Increased adult afPWV was significantly associated with higher adulthood (P AUC (P AUC (P AUC (P = 0.007) were significantly greater among the current smokers than among the nonsmokers. DBP showed a similar pattern regarding the smoking-BP interaction on afPWV. These results, by showing the synergistic effect of tobacco smoking and long-term BP measures from childhood to adulthood on arterial stiffening process, underscore the importance of undertaking preventive strategies early in life and smoking behavior control.

  4. The association of ABO blood groups with extent of coronary atherosclerosis in Croatian patients suffering from chronic coronary artery disease.

    Science.gov (United States)

    Karabuva, Svjetlana; Carević, Vedran; Radić, Mislav; Fabijanić, Damir

    2013-01-01

    The aim of study was to: 1) examine the relationship between ABO blood groups and extent of coronary atherosclerosis in patients with chronic coronary artery disease (CAD), 2) compare ABO blood groups distribution in CAD patients and general population, 3) examine possible differences in traditional risk factors frequency in CAD patients with different ABO blood groups. In the 646 chronic CAD patients (72.4% males) coronary angiograms were scored by quantitative assessment using multiple angiographic scoring system, Traditional risk factors were self reported or measured by standard methods. ABO blood distribution of patients was compared with group of 651 healthy blood donors (74.6% males). Among all ABO blood group patients there was no significant difference between the extent of coronary atherosclerosis with regard to all the three scoring systems: number of affected coronary arteries (P = 0.857), Gensini score (P = 0.818), and number of segments narrowed > 50% (P = 0.781). There was no significant difference in ABO blood group distribution between CAD patients and healthy blood donors. Among CAD patients, men with blood group AB were significantly younger than their pairs with non-AB blood groups (P = 0.008). Among CAD patients with AB blood group, males groups (P = 0.003). No association between ABO blood groups and the extent of coronary atherosclerosis in Croatian CAD patients is observed. Observation that AB blood group might possibly identify Croatian males at risk to develop the premature CAD has to be tested in larger cohort of patients.

  5. Ambulatory blood pressure and blood lipids in a multiethnic sample of healthy adults.

    Science.gov (United States)

    James, Gary D; Van Berge-Landry, Helene M; Morrison, Lynn A; Reza, Angela M; Nicolaisen, Nicola M; Bindon, James R; Brown, Daniel E

    2013-01-01

    Elevated blood pressure (BP), elevated serum cholesterol, and aberrant lipoprotein fractions (low levels of high-density lipoprotein (HDL) and high levels of low-density lipoprotein fractions and triglycerides) have all been used as measures that assess the "metabolic syndrome" and more recently in indexes of allostatic load, which are designed to assess the degree of integrated metabolic pathology. While there are ample data regarding the interrelationships of these measures in various pathophysiological settings, there are limited data regarding the interrelationship of ambulatory BP (ABP) and blood lipids in healthy subjects. The present study evaluates ABP-blood lipid relationships in a multiethnic sample of healthy adults. The subjects were 37 men (age = 40.9 ± 10.7 years) and 42 women (age = 35.8 ± 10.4 years) who were employed as hotel workers in Hawaii. Each wore an ABP monitor for one midweek workday and had pressures averaged in three daily microenvironments (work, home, and during sleep). They also had fasting blood samples taken for lipid profiling. Multivariate analysis of covariance shows that there was a strong inverse relationship between HDL and both systolic (P act as a group in healthy adults but that higher HDL is associated with lower BP. This latter finding is consistent with research that shows that HDL promotes vasodilation via its effect on endothelial nitric oxide synthase. Copyright © 2013 Wiley Periodicals, Inc.

  6. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  7. Blood pressure and calf muscle oxygen extraction during plantar flexion exercise in peripheral artery disease.

    Science.gov (United States)

    Luck, J Carter; Miller, Amanda J; Aziz, Faisal; Radtka, John F; Proctor, David N; Leuenberger, Urs A; Sinoway, Lawrence I; Muller, Matthew D

    2017-07-01

    Peripheral artery disease (PAD) is an atherosclerotic vascular disease that affects 200 million people worldwide. Although PAD primarily affects large arteries, it is also associated with microvascular dysfunction, an exaggerated blood pressure (BP) response to exercise, and high cardiovascular mortality. We hypothesized that fatiguing plantar flexion exercise that evokes claudication elicits a greater reduction in skeletal muscle oxygenation (SmO 2 ) and a higher rise in BP in PAD compared with age-matched healthy subjects, but low-intensity steady-state plantar flexion elicits similar responses between groups. In the first experiment, eight patients with PAD and eight healthy controls performed fatiguing plantar flexion exercise (from 0.5 to 7 kg for up to 14 min). In the second experiment, seven patients with PAD and seven healthy controls performed low-intensity plantar flexion exercise (2.0 kg for 14 min). BP, heart rate (HR), and SmO 2 were measured continuously using near-infrared spectroscopy (NIRS). SmO 2 is the ratio of oxygenated hemoglobin to total hemoglobin, expressed as a percent. At fatigue, patients with PAD had a greater increase in mean arterial BP (18 ± 2 vs. vs. 10 ± 2 mmHg, P = 0.029) and HR (14 ± 2 vs. 6 ± 2 beats/min, P = 0.033) and a greater reduction in SmO 2 (-54 ± 10 vs. -12 ± 4%, P = 0.001). However, both groups had similar physiological responses to low-intensity, nonpainful plantar flexion exercise. These data suggest that patients with PAD have altered oxygen uptake and/or utilization during fatiguing exercise coincident with an augmented BP response. NEW & NOTEWORTHY In this laboratory study, patients with peripheral artery disease performed plantar flexion exercise in the supine posture until symptoms of claudication occurred. Relative to age- and sex-matched healthy subjects we found that patients had a higher blood pressure response, a higher heart rate response, and a greater reduction in skeletal muscle oxygenation as

  8. Experimental investigation of the flow of a blood analogue fluid in a replica of a bifurcated small artery.

    Science.gov (United States)

    Anastasiou, A D; Spyrogianni, A S; Koskinas, K C; Giannoglou, G D; Paras, S V

    2012-03-01

    The scope of this work is to study the pulsatile flow of a blood mimicking fluid in a micro channel that simulates a bifurcated small artery, in which the Fahraeus-Lindqvist effect is insignificant. An aqueous glycerol solution with small amounts of xanthan gum was used for simulating viscoelastic properties of blood and in vivo flow conditions were reproduced. Local flow velocities were measured using micro Particle Image Velocimetry (μ-PIV). From the measured velocity distributions, the wall shear stress (WSS) and its variation during a pulse were estimated. The Reynolds numbers employed are relatively low, i.e. similar to those prevailing during blood flow in small arteries. Experiments both with a Newtonian and a non-Newtonian fluid (having asymptotic viscosity equal to the viscosity of the Newtonian one) proved that the common assumption that blood behaves as a Newtonian fluid is not valid for blood flow in small arteries. It was also shown that the outer wall of the bifurcation, which is exposed to a lower WSS, is more predisposed to atherosclerotic plaque formation. Moreover, this region in small vessels is shorter than the one in large arteries, as the developed secondary flow decays faster. Finally, the WSS values in small arteries were found to be lower than those in large ones. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. A case of reocclusion of the renal artery diagnosed by the color Doppler method with evaluation of blood flow direction in the collateral circulation of the kidney in addition to the non-detectable blood signal in the renal artery.

    Science.gov (United States)

    Hirano, Megumi; Ohta, Tomoyuki; Nakata, Norio; Kawakami, Reina; Takamura, Kimihiro; Matsuda, Tosiharu; Nishioka, Makiko; Sakurai, Tomoo; Matsuo, Kouichi; Miyamoto, Yukio

    2014-10-01

    A 23-year-old woman was referred to our hospital for an interventional procedure for chronic total occlusion of the right renal artery, probably due to fibromuscular dysplasia (FMD), and for control of renal vascular hypertension. Before percutaneous transluminal renal angioplasty (PTRA), aortography revealed collateral circulation to the right kidney from the lower lumbar artery. After PTRA, however, blood flow in the renal side of the collateral circulation flowed outside from the right renal parenchyma. 4 months later, we could not find a blood flow signal in the right renal artery, and there was a contrary flow signal in the right kidney parenchyma continuously from the extrahilar vessel, possibly a collateral artery. These findings indicated reocclusion of the right artery. We confirmed reocclusion of the renal artery and collateral feeding by contrast dynamic computed tomography (CT), and PTRA was performed again without any complications or reocclusion for 5 months. This is the first case report showing that a back-flowing signal in the right renal parenchyma from the extrahilar artery is useful as an indirect finding suggesting reocclusion.

  10. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    Directory of Open Access Journals (Sweden)

    M Y Abdollahzadeh Jamalabadi

    Full Text Available Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  11. Black blood MRI in suspected large artery primary angiitis of the central nervous system.

    Science.gov (United States)

    Pfefferkorn, Thomas; Linn, Jennifer; Habs, Maximilian; Opherk, Christina; Cyran, Clemens; Ottomeyer, Caroline; Straube, Andreas; Dichgans, Martin; Nikolaou, Konstantin; Saam, Tobias

    2013-07-01

    Single case reports suggest that black blood MRI (T1-weighted fat and blood suppressed sequences with and without contrast injection; BB-MRI) may visualize intracranial vessel wall contrast enhancement (CE) in primary angiitis of the central nervous system (PACNS). In this single-center observational pilot study we prospectively investigated the value of BB-MRI in the diagnosis of large artery PACNS. Patients with suspected large artery PACNS received a standardized diagnostic program including BB-MRI. Vessel wall CE was graded (grade 0-2) by two experienced readers blinded to clinical data and correlated to the final diagnosis. Four of 12 included patients received a final diagnosis of PACNS. All of them showed moderate (grade 1) to strong (grade 2) vessel wall CE at the sites of stenosis. A moderate (grade 1) vessel wall CE grade was also observed in 6 of the remaining 8 patients in whom alternative diagnoses were made: arteriosclerotic disease (n = 4), intracranial dissection (n = 1), and Moyamoya disease (n = 1). Our pilot study demonstrates that vessel wall CE is a frequent finding in PACNS and its mimics. Larger trials will be necessary to evaluate the utility of BB-MRI in the diagnostic workup of PACNS. Copyright © 2012 by the American Society of Neuroimaging.

  12. A model for investigating the control of muscle blood flow: the masseteric artery in conscious rabbits

    International Nuclear Information System (INIS)

    Roatta, S; Mohammed, M; Turturici, M; Milano, L; Passatore, M

    2010-01-01

    The complex interplay of neural, metabolic, myogenic and mechanical mechanisms that regulate blood flow in skeletal muscle (MBF) is still incompletely understood. For the first time, a method is presented for high time-resolution recording of MBF from a purely muscular artery in physiological conditions. Ultrasound perivascular flow probes were implanted (n = 15) mono- or bilaterally around the masseteric branch of the facial artery in nine rabbits and tested up to 16 days after implant. Reliable and stable recordings were achieved in 50% of implants. Blood flow was observed to increase from a resting level of 0.2–0.3 ml min −1 up to 4.0–6.0 ml min −1 during spontaneous masticatory activity. In addition, within single masticatory cycles marked back flow transients could be observed (peak flow = −10 ml min −1 ) during powerful masticatory strokes but not during mild mastication. The possibility of (1) surgically removing the sympathetic supply to the relevant vascular bed and of (2) bilaterally monitoring the perfusion of masseter muscles thus allowing to use one side as control side for different types of interventions makes this model a useful tool for disentangling the different mechanisms involved in the control of MBF. (note)

  13. Gaming the System: Developing an Educational Game for Securing Principles of Arterial Blood Gases.

    Science.gov (United States)

    Boyd, Cory Ann; Warren, Jonah; Glendon, Mary Ann

    2016-01-01

    This article describes the development process for creating a digital educational mini game prototype designed to provide practice opportunities for learning fundamental principles of arterial blood gases. Mini games generally take less than an hour to play and focus on specific subject matter. An interdisciplinary team of faculty from two universities mentored student game developers to design a digital educational mini game prototype. Sixteen accelerated bachelor of science in nursing students collaborated with game development students and playtested the game prototype during the last semester of their senior year in nursing school. Playtesting is a form of feedback that supports an iterative design process that is critical to game development. A 10-question survey was coupled with group discussions addressing five broad themes of an archetypical digital educational mini game to yield feedback on game design, play, and content. Four rounds of playtesting and incorporating feedback supported the iterative process. Accelerated bachelor of science in nursing student playtester feedback suggests that the digital educational mini game prototype has potential for offering an engaging, playful game experience that will support securing the fundamental principles of arterial blood gases. Next steps are to test the digital educational mini game for teaching and learning effectiveness. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Venepuncture versus heel lance for blood sampling in term neonates.

    Science.gov (United States)

    Shah, Vibhuti S; Ohlsson, Arne

    2011-10-05

    Heel lance has been the conventional method of blood sampling in neonates for screening tests. Neonates undergoing heel lance experience pain which cannot be completely alleviated. To determine whether venepuncture or heel lance is less painful and more effective for blood sampling in term neonates. Randomized or quasi-randomised controlled trials comparing pain response to venepuncture versus heel lance were identified by searching the Cochrane Central Regsiter of Controlled Trials (CENTRAL, The Cochrane Library), MEDLINE, EMBASE, CINAHL, and clinical trials registries in May 2011. Trials comparing pain response to venepuncture versus heel lance with or with out the use of a sweet tasting solution as a co-intervention in term neonates. Outcomes included pain response to venepuncture versus heel lance with or without the use of a sweet tasting solution using validated pain measures, the need of repeat sampling and cry characteristics. Analyses included typical relative risk (RR), risk difference (RD), number needed to treat (NNT), weighted mean difference (WMD) and standardized mean difference (SMD) with their 95% confidence intervals (CI). Between study heterogeneity was reported including the I squared (I(2)) test. Six studies (n = 478) of variable quality were included. A composite outcome of Infant Pain Scale (NIPS), Neonatal Facial Action Coding System (NFCS) and/or Premature Infant Pain Profile (PIPP) score was reported in 288 infants, who did not receive a sweet tasting solution. Meta-analysis showed a significant reduction in the venepuncture versus the heel lance group (SMD -0.76, 95% CI -1.00 to -0.52; I(2) = 0%). When a sweet tasting solution was provided the SMD remained significant favouring the venepuncture group (SMD - 0.38, 95% CI -0.69 to -0.07). The typical RD for requiring more than one skin puncture for venepuncture versus heel lance (reported in 4 studies; n = 254) was -0.34 (95% CI -0.43 to -0.25; I(2) = 97%). The NNT to avoid one repeat skin

  15. The effect of time from last food intake on arterial blood gases: Implication on reference values

    Directory of Open Access Journals (Sweden)

    Zahedpour Anaraki M

    2000-08-01

    Full Text Available Arterial blood gas parameters were analyzed in forty-nine healthy persons (31 males, 18 females to detemine reference values fo these parameters and their relation to the time from last food intake to arterial puncture (T. The mean ± standard deviation of arterial oxygen pressure, arterial carbon dioxide pressure and pH at core body temperature were 84.4±7.0 mmHg (Male: 83.0±6.5, Female: 86.7±73, 37.7±2.8 mmHg (Male: 38.5±2.7, Female: 36.2±2.4 respectively 7.41±0.02 (Male: 7.41±0.02 Female: 7.42±0.03. the mean PCO2 was lower in comparison with most of the studies at sea level. The difference between males and females was significant in PCO2 and PH (P=0.004, P=0.02 respectively but in was not significant in PO2 (P=0.07. The PCO2 and pH had no statistically significant relatioship with age (P=0.42, P=0.25 respectively. The relationship between Po2 with age, PCO2 and T was significant (P=0.02, P=0.017, and P=0.019 respectively. The best linear predictive equation was: Po2= 1.28 AO2-29.4 for T10hours Þ AO2 = 0.21(Baro-47 – (1.2PCO2

  16. Morning pressor surge, blood pressure variability, and arterial stiffness in essential hypertension.

    Science.gov (United States)

    Pucci, Giacomo; Battista, Francesca; Anastasio, Fabio; Schillaci, Giuseppe

    2017-02-01

    An excess morning blood pressure surge (MBPS) may portend an increased cardiovascular risk, but the mechanisms thereof have been little investigated. The link between MBPS, short-term blood pressure (BP) variability, and arterial stiffness has not been entirely defined. In 602 consecutive untreated hypertensive patients (48 ± 12 years, 61% men, office BP 149/93 ± 17/10 mmHg), we measured carotid-femoral pulse wave velocity (cf-PWV, SphygmoCor) and 24-h ambulatory BP. Using self-reported sleep and wake times, MBPS was defined as sleep-trough (ST-MBPS), prewaking, rising. Short-term BP variability was calculated as weighted 24-h SBP SD and average real variability of 24-h SBP (ARV), that is, average of absolute differences between consecutive SBP readings. ST-MBPS (r = 0.16, P < 0.001) and rising MBPS (r = 0.12, P = 0.003) showed a direct correlation with cf-PWV, whereas prewaking MBPS had no such relation (r = 0.06, P = 0.14). Only ST-MBPS was independently associated with cf-PWV (t = 1.96, P = 0.04) after adjustment for age, sex, height, office mean arterial pressure, heart rate, and renal function. This association was lost after further adjustment for weighted 24-h SBP SD (P = 0.13) or ARV (P = 0.24). ARV was a significant mediator of the relationship between ST-MBPS and cf-PWV (P = 0.003). In untreated hypertension, ST-MBPS has a direct relation with aortic stiffness, which is mediated by an increased ARV. The adverse effects of MBPS may be partly explained by its link with arterial stiffness, mediated by short-term SBP variability.

  17. Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET

    International Nuclear Information System (INIS)

    Boellaard, R.; Lingen, A. van; Balen, S.C.M. van; Hoving, B.G.; Lammertsma, A.A.

    2001-01-01

    The first performance tests of a new fully programmable blood sampling device for monitoring blood radioactivity during positron emission tomography (PET) are described. Blood is withdrawn through 1-mm internal diameter tubing using an infusion pump which can be operated at rates varying from 0 to 600 ml/h. Activity in blood is measured by a 6-cm-thick bismuth germanate crystal connected to a photomultiplier tube and multichannel analyser (MCA) which are positioned within 6 cm lead shielding. Positioning of the tubing is an exact and simple procedure. The minimal readout time of the MCA is 1 s. Two independent energy windows can be set. Operation of the pump and MCA is fully controlled by a PC, i.e. sampling time, interval time and pump rate can be varied at any time during the PET scan by user-defined scripts. A number of characteristics of the new system were studied, such as sensitivity, dead time, linearity, effect of background radiation and pump rate as a function of input pressure. In addition, dispersion was measured as a function of pump rate. Finally, first clinical results were compared with manual samples. The sensitivity equalled 0.7 and 0.2 cps/Bq for 511- and 1022-keV 30% energy windows, respectively, and the system dead time was 500 ns. The system remained linear within 2% with activity concentrations up to 2.5 MBq/cc. Short-term reproducibility was better than 3% for a 1-h period. Long-term reproducibility was about 5% (1SD), which was mainly caused by variation in the diameter of the tubing. If the device was positioned in such a way that maximum shielding was directed towards the patient, the effects of background radiation from the patient on the measured activity concentration for clinically relevant conditions was minimal ( -1 were observed for pump rates higher than 300 ml/h, indicating that the system dispersion is small. Clinical data showed an excellent agreement to within 3% (1SD) between the results obtained with the new system and

  18. The Effects of Creatine Monohydrate on Permeability of Coronary Artery Endothelium and Level of Blood Lipoprotein in Diabetic Rats.

    Science.gov (United States)

    Rahmani, Asghar; Asadollahi, Khairollah; Soleimannejad, Kourosh; Khalighi, Zahra; Mohsenzadeh, Yosouf; Hemati, Ruhollah; Moradkhani, Atefeh; Abangah, Ghobad

    2016-09-01

    Creatine monohydrate has beneficial effects on serum glucose. This study aimed to investigate the effects of creatine on serum biochemical markers and permeability of coronary arteries among diabetic rats. 32 Wistar rats, which weighed 150-200 grams were randomly divided into 4 groups including: group I, control; group II, creatine monohydrate; group III, diabetic rats; and group IV, diabetic rats + creatine. Creatine monohydrate was applied by 400 mg/kg/daily for 5 months. Animals' weights and blood samples were taken before and after the study. Endothelial permeability rate was measured by Evans Blue method. Data were analysed by SPSS 16. At the end of fifth month, rats' weights in diabetic group under treatment with creatine, compared to those without, increased significantly (pcreatine (pcreatine compared to untreated groups, closed to the intact group (pcreatine monohydrate caused an improvement of serum biochemical markers associated with diabetes and reduced the permeability rate of coronary arteries among diabetic rats. © 2016 by the Association of Clinical Scientists, Inc.

  19. En bloc resection of skull base tumor including internal carotid artery. Preoperative evaluation of cerebral blood flow

    International Nuclear Information System (INIS)

    Okamoto, Yoshitaka; Matsuzaki, Zensei; Kamijo, Atsushi; Ogino, Jun; Nagaseki, Yoshishige; Nukui, Hideaki; Yokomizo, Michinori; Togawa, Kiyoshi

    1998-01-01

    Carotid artery resection yields a possibility of cure in patients with advanced head and neck carcinoma involving the carotid artery. However, the criteria for the identification of those who are vulnerable to neurologic injury after resection have not been established. Interposition graft covered with a well-vascularized flap could minimize the rate of perioperative morbidity. Particularly, when an extensive resection of the skull base including carotid artery and sigmoid vein, is planned, extracranial-intracranial bypass should be considered to minimize the risks of neurologic morbidity, even if preresection positron emission tomography during balloon test occlusion of internal carotid artery suggested the adequacy of hemispheric collateral blood flow. In these cases, the temporary occlusion of the carotid artery is not an accurate prediction of the morbidity after permanent occlusion. (author)

  20. Time course and recovery of arterial blood gases during exacerbations in adults with Cystic Fibrosis.

    LENUS (Irish Health Repository)

    Waterhouse, D F

    2012-02-01

    INTRODUCTION: Hypoxia and hypercapnia are closely linked to morbidity and mortality in patients with Cystic Fibrosis (CF). The aims of this study were to describe the changes in blood gases during and following an acute pulmonary exacerbation in adults with CF. METHODS: We performed a prospective observational study of patients with CF admitted for management of an acute exacerbation. Blood gas and spirometric analysis was performed on admission, throughout the treatment period, and 31 days after discharge (day 45). RESULTS: At presentation, eight of nineteen patients had evidence of either hypoxia (PaO(2)<8 kPa) and\\/or hypercapnia (PaCO(2)>6.6 kPa). Blood gas parameters stabilized following two weeks of intravenous antibiotic therapy, with little difference evident in between treatment completion and subsequent review following discharge. Hypercapnia reversed in three patients, with persistent hypercapnia evident in two patients. CONCLUSION: In our study group, hypoxemia and hypercapnia were frequently observed at presentation of the acute exacerbation. Blood gases stabilized following two weeks of intravenous antibiotic therapy, with arterial PCO(2) one month following hospital discharge generally similar to that at time of discharge.

  1. Comportamiento de percentiles de tensión arterial asociados a factores de riesgo en escolares Performance of blood pressure percentiles associated with risk factors in students

    Directory of Open Access Journals (Sweden)

    Javier Jesús Suárez Rivera

    2004-04-01

    Full Text Available Se realizó un estudio prospectivo y descriptivo del universo de escolares desde preescolar hasta 6to. grado de la Escuela Primaria "Jesús Menéndez," de la localidad de Alamar, en el período comprendido desde septiembre de 2000 hasta febrero de 2001, con el objetivo de estimar el comportamiento de los percentiles (pc de tensión arterial, según edad y sexo, así como los factores de riesgo asociados. La muestra quedó constituida por 743 alumnos, a los cuales se les realizó un examen físico que incluyó peso, talla, toma de tensión arterial y una encuesta abierta. Con los datos obtenidos se dividió la población en 4 grupos de estudio según percentiles de tensión arterial: grupo I ( 95 pc, según la literatura extranjera consultada, y se relacionaron con factores de riesgo. El mayor número de escolares estudiados se encontraban con cifras de tensión arterial ubicadas en canales menores al 50 pc (88,83 %, y el factor de riesgo que se encontró con mayor frecuencia fue el antecedente familiar de hipertensión arterial. Solo 6 escolares presentaron cifras de tensión arterial superiores al 95 pc.A prospective descriptive study of students from kindergarten to 6th grade in "Jesús Menendez" elementary school located in Alamar was performed from September 2000 to February 2001 to find out the performance of blood pressure percentiles by age and sex as well as the associated risk factors. The sample was comprised by 743 students who were physically examined, taking into account weight, height, blood pressure and an open survey. The obtained data allowed us to divide the population into 4 groups by blood pressure percentiles; group 1(95 pc according to the reviewed foreign literature and they were related to risk factors. The blood pressure values of the highest number of studied students were under 50 pc (88,83 % and the most frequent risk factors was family history of blood hypertension. Only 6 students had blood pressure value over 95 %.

  2. Basic arterial blood gas biomarkers as a predictor of mortality in tetralogy of Fallot patients

    Directory of Open Access Journals (Sweden)

    Vandana Bhardwaj

    2017-01-01

    Full Text Available Background: Serum lactate and base deficit have been shown to be a predictor of morbidity and mortality in critically ill patients. Poor preoperative oxygenation appears to be one of the significant factors that affects early mortality in tetralogy of Fallot (TOF. There is little published literature evaluating the utility of serum lactate, base excess (BE, and oxygen partial pressure (PO 2 as simple, widely available, prognostic markers in patients undergoing surgical repair of TOF. Materials and Methods: This prospective, observational study was conducted in 150 TOF patients, undergoing elective intracardiac repair. PO 2 , BE, and lactate levels at three different time intervals were recorded. Arterial blood samples were collected after induction (T1, after cardiopulmonary bypass (T2, and 48 h (T3 after surgery in the Intensive Care Unit (ICU. To observe the changes in PO 2 , BE, and lactate levels over a period of time, repeated measures analysis was performed with Bonferroni method. The receiver operating characteristics (ROC analysis was used to find area under curve (AUC and cutoff values of various biomarkers for predicting mortality in ICU. Results: The patients who could not survive showed significant elevated lactate levels at baseline (T1 and postoperatively (T2 as compared to patients who survived after surgery (P < 0.001. However, in nonsurvivors, the BE value decreased significantly in the postoperative period in comparison to survivors (−2.8 ± 4.27 vs. 5.04 ± 2.06 (P < 0.001. In nonsurvivors, there was a significant fall of PO 2 to a mean value of 59.86 ± 15.09 in ICU (T3, whereas those who survived had a PO 2 of 125.86 ± 95.09 (P < 0.001. The ROC curve analysis showed that lactate levels (T3 have highest mortality predictive value (AUC: 96.9% as compared to BE (AUC: 94.5% and PO 2 (AUC: 81.1%. Conclusion: Serum lactate and BE may be used as prognostic markers to predict mortality in patients undergoing TOF repair. The

  3. Balloon test occlusion of the internal carotid artery with stable xenon/CT cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Erba, S.M.; Horton, J.A.; Latchaw, R.E.; Yonas, H.; Sekhar, L.; Schramm, V.; Pentheny, S.

    1988-01-01

    We describe a technique to predict preoperatively the safety of permanently occluding an internal carotid artery. The method was performed by imaging stable xenon cerebral blood flow (CBF) with the internal carotid artery both open and temporarily occluded with a nondetachable balloon on a double lumen Swan-Ganz catheter. Patients were those in whom we planned to sacrifice the internal carotid artery (those with giant or inaccessible aneurysms) or those in whom such a sacrifice was at least likely (those with skull base tumors). Patients were divided into three groups on the basis of a comparison of occluded and nonoccluded CBF values. Group-I patients had no significant change in CBF with internal carotid artery occlusion; group-II patients showed a symmetric decrease in CBF; and group-III patients had an asymmetric decrease in CBF, always greater on the occluded side. A fourth group clinically failed to tolerate even brief carotid occlusion. The internal carotid artery in one patients from group III was sacrificed at surgery: the size and shape of his postoperative infarct corresponded almost exactly to the area of asymmetrically decreased CBF on his occluded study. The data suggest that if surgery is likely to result in permanent occlusion of the internal carotid artery, then patients who are at risk for delayed neurologic injury due to a compromised cerebral blood flow should have arterial bypass grafts before such surgery is performed

  4. Passive heat therapy improves endothelial function, arterial stiffness and blood pressure in sedentary humans.

    Science.gov (United States)

    Brunt, Vienna E; Howard, Matthew J; Francisco, Michael A; Ely, Brett R; Minson, Christopher T

    2016-09-15

    A recent 30 year prospective study showed that lifelong sauna use reduces cardiovascular-related and all-cause mortality; however, the specific cardiovascular adaptations that cause this chronic protection are currently unknown. We investigated the effects of 8 weeks of repeated hot water immersion ('heat therapy') on various biomarkers of cardiovascular health in young, sedentary humans. We showed that, relative to a sham group which participated in thermoneutral water immersion, heat therapy increased flow-mediated dilatation, reduced arterial stiffness, reduced mean arterial and diastolic blood pressure, and reduced carotid intima media thickness, with changes all on par or greater than what is typically observed in sedentary subjects with exercise training. Our results show for the first time that heat therapy has widespread and robust effects on vascular function, and as such, could be a viable treatment option for improving cardiovascular health in a variety of patient populations, particularly those with limited exercise tolerance and/or capabilities. The majority of cardiovascular diseases are characterized by disorders of the arteries, predominantly caused by endothelial dysfunction and arterial stiffening. Intermittent hot water immersion ('heat therapy') results in elevations in core temperature and changes in cardiovascular haemodynamics, such as cardiac output and vascular shear stress, that are similar to exercise, and thus may provide an alternative means of improving health which could be utilized by patients with low exercise tolerance and/or capabilities. We sought to comprehensively assess the effects of 8 weeks of heat therapy on biomarkers of vascular function in young, sedentary subjects. Twenty young, sedentary subjects were assigned to participate in 8 weeks (4-5 times per week) of heat therapy (n = 10; immersion in a 40.5°C bath sufficient to maintain rectal temperature ≥ 38.5°C for 60 min per session) or thermoneutral water

  5. Blood Pressure Response to Main Renal Artery and Combined Main Renal Artery Plus Branch Renal Denervation in Patients With Resistant Hypertension.

    Science.gov (United States)

    Fengler, Karl; Ewen, Sebastian; Höllriegel, Robert; Rommel, Karl-Philipp; Kulenthiran, Saaraaken; Lauder, Lucas; Cremers, Bodo; Schuler, Gerhard; Linke, Axel; Böhm, Michael; Mahfoud, Felix; Lurz, Philipp

    2017-08-10

    Single-electrode ablation of the main renal artery for renal sympathetic denervation showed mixed blood pressure (BP)-lowering effects. Further improvement of the technique seems crucial to optimize effectiveness of the procedure. Because sympathetic nerve fibers are closer to the lumen in the distal part of the renal artery, treatment of the distal main artery and its branches has been shown to reduce variability in treatment effects in preclinical studies and a recent randomized trial. Whether this optimized technique improves clinical outcomes remains uncertain. We report a 2-center experience of main renal artery and combined main renal artery plus branches renal denervation in patients with resistant hypertension using a multielectrode catheter. Twenty-five patients with therapy-resistant hypertension underwent renal sympathetic denervation with combined main renal artery and renal branch ablation and were compared to matched controls undergoing an ablation of the main renal artery only. BP change was assessed by ambulatory measurement at baseline and after 3 months. At baseline, BP was balanced between the groups. After 3 months, BP changed significantly in the combined ablation group (systolic/diastolic 24-hour mean and daytime mean BP -8.5±9.8/-7.0±10.7 and -9.4±9.8/-7.1±13.5 mm Hg, P renal artery and branches appears to improve BP-lowering efficacy and should be further investigated. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  6. A prospective study of glomerular filtration rate and arterial blood pressure in insulin-dependent diabetics with diabetic nephropathy

    DEFF Research Database (Denmark)

    Parving, H H; Smidt, U M; Friisberg, B

    1981-01-01

    Glomerular filtration rate (GFR, single bolus 51Cr-EDTA technique), serum creatinine, proteinuria and arterial blood pressure have been measured prospectively in 14 young onset insulin-dependent diabetics selected by of persistent proteinuria (greater than 0.5 g/day) secondary to diabetic...... in arterial blood pressure to a hypertensive level is an early feature of diabetic nephropathy in young insulin-dependent diabetics....... and 112/mumol/l (NS), proteinuria increased from 1.8 to 3.3 g/day (p less than 0.001) and arterial blood pressure rose from 132/88 to 153/101 mmHg (p less than 0.001). Glomerular filtration rate decreased linearly with time (slope = -0.75, r = 0.99, p less than 0.001) by a mean of 0.75 ml/min/month (range...

  7. Heat stress exacerbates the reduction in middle cerebral artery blood velocity during prolonged self-paced exercise.

    Science.gov (United States)

    Périard, J D; Racinais, S

    2015-06-01

    This study examined the influence of hyperthermia on middle cerebral artery mean blood velocity (MCA Vmean). Eleven cyclists undertook a 750 kJ self-paced time trial in HOT (35 °C) and COOL (20 °C) conditions. Exercise time was longer in HOT (56 min) compared with COOL (49 min; P blood flow, and heart rate were higher throughout HOT compared with COOL (P blood pressure and oxygen uptake were lower from 50% of work completed onward in HOT compared with COOL (P heat appears to have exacerbated the reduction in MCA Vmean, in part via increases in peripheral blood flow and a decrease in arterial blood pressure. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Arterial spin labeling blood flow magnetic resonance imaging for evaluation of renal injury.

    Science.gov (United States)

    Liu, Yupin P; Song, Rui; Liang, Chang hong; Chen, Xin; Liu, Bo

    2012-08-15

    A multitude of evidence suggests that iodinated contrast material causes nephrotoxicity; however, there have been no previous studies that use arterial spin labeling (ASL) blood flow functional magnetic resonance imaging (fMRI) to investigate the alterations in effective renal plasma flow between normointensive and hypertensive rats following injection of contrast media. We hypothesized that FAIR-SSFSE arterial spin labeling MRI may enable noninvasive and quantitative assessment of regional renal blood flow abnormalities and correlate with disease severity as assessed by histological methods. Renal blood flow (RBF) values of the cortex and medulla of rat kidneys were obtained from ASL images postprocessed at ADW4.3 workstation 0.3, 24, 48, and 72 h before and after injection of iodinated contrast media (6 ml/kg). The H&E method for morphometric measurements was used to confirm the MRI findings. The RBF values of the outer medulla were lower than those of the cortex and the inner medulla as reported previously. Iodinated contrast media treatment resulted in decreases in RBF in the outer medulla and cortex in spontaneously hypertensive rats (SHR), but only in the outer medulla in normotensive rats. The iodinated contrast agent significantly decreased the RBF value in the outer medulla and the cortex in SHR compared with normotensive rats after injection of the iodinated contrast media. Histological observations of kidney morphology were also consistent with ASL perfusion changes. These results demonstrate that the RBF value can reflect changes of renal perfusion in the cortex and medulla. ASL-MRI is a feasible and accurate method for evaluating nephrotoxic drugs-induced kidney damage.

  9. Changes in myocardial blood flow and S-T segment elevation following coronary artery occlusion in dogs

    International Nuclear Information System (INIS)

    Smith, H.J.; Singh, B.N.; Norris, R.M.; John, M.B.; Hurley, P.J.

    1975-01-01

    The relationship between regional blood flow and epicardial S-T segment elevation was studied in 26 open-chest anesthetized dogs with left anterior coronary artery ligations. Changes in myocardial blood flow, measured with 15 +- 5 μ (diameter) microspheres labeled with 141 Ce, 85 Sr, and 169 Yb, were correlated with summated S-T segment elevations 15 minutes, 1 hour, and 2 hours after coronary artery occlusion. In normal areas, myocardial blood flow was 113 +- 5 ml/min 100 g -1 and summated S-T segment elevation was 0.3 +- 0.2 mv. Fifteen minutes after coronary artery occlusion in 26 dogs, S-T segment elevation was 5.7 +- 0.7 mv over the center of the infarct and myocardial blood flow was 10 +- 1 ml/min 100 g -1 ; over the border zone, myocardial blood flow was 63 +- 4 ml/min 100 g -1 and S-T segment elevation was 3.1 +- 0.1 mv. One third of the areas with a myocardial blood flow of 10 ml/min 100 g -1 or less had no S-T segment elevation. In the center and border zones of the infarct in 9 dogs, myocardial blood flow increased from 11 +- 2 and 67 +- 8 ml/min 100 g -1 15 minutes after occlusion to 20 +- 4 and 84 +- 12 ml/min 100 g -1 , respectively, 2 hours after coronary artery occlusion. These increases were not associated with a significant reduction in summated S-T segment elevation. The results do not suggest a simple quantitative relationship between epicardial S-T segment elevation and myocardial blood flow following acute coronary artery occlusion

  10. Prognostic value of renal fractional flow reserve in blood pressure response after renal artery stenting (PREFER study).

    Science.gov (United States)

    Kądziela, Jacek; Januszewicz, Andrzej; Prejbisz, Aleksander; Michałowska, Ilona; Januszewicz, Magdalena; Florczak, Elżbieta; Kalińczuk, Łukasz; Norwa-Otto, Bożena; Warchoł, Ewa; Witkowski, Adam

    2013-01-01

    The aim of our study was to determine a potential relationship between resting translesional pressures ratio (Pd/Pa ratio), renal fractional flow reserve (rFFR) and blood pressure response after renal artery stenting. Thirty five hypertensive patients (49% males, mean age 64 years) with at least 60% stenosis in angiography, underwent renal artery stenting. Translesional systolic pressure gradient (TSPG), Pd/Pa ratio (the ratio of mean distal to lesion and mean proximal pressures) and hyperemic rFFR - after intrarenal administration of papaverine - were measured before stent implantation. Ambulatory blood pressure measurements (ABPM) were recorded before the procedure and after 6 months. The ABPM results were presented as blood pressure changes in subgroups of patients with normal (≥ 0.9) vs. abnormal (renal artery stenting. Median changes of 24-h systolic/diastolic blood pressure were comparable in patients with abnormal vs. normal Pd/Pa ratio (-4/-3 vs. 0/2 mm Hg; p = NS) and with abnormal vs. normal rFFR (-2/-1 vs. -2/-0.5 mm Hg, respectively). Physiological assessment of renal artery stenosis using Pd/Pa ratio and papaverine- induced renal fractional fl ow reserve did not predict hypertension response after renal artery stenting.

  11. The impact of renal artery stent revascularization on blood pressure: 1-year follow-up of 110 cases

    International Nuclear Information System (INIS)

    Wang Chao; Zou Yinghua; Yang Min; Wang Jian; Tong Xiaoqiang; Song Li

    2007-01-01

    Objective: To investigate the effect of renal artery revascularization through renal artery stenting(PTRAS)on blood pressure in patients with renal artery stenosis. Methods: During April 2000 through May 2005 110 cases of renal artery stenosis received PTRAS and followed up for at least 1 year with blood pressure measurements pre-and 1 year post-PTRAS. Results: The technical success rate was 100% for all 110 cases. The renal artery stenosis were decreased from 60%-100% before PTRAS to 0%-15% after the stent placement. There was significant difference between blood pressure pre-and 1 year post PTRAS. Systolic pressures decreased from(153 ± 32) mmHg to(131 ± 27) mmHg and diastolic pressures from(87 ± 19) mmHg to(75 ± 19) mmHg. The administration of antihypertensive diugs reduced from(2.6 ± 0.9 ) sorts to(1.9 ± 0.9) sorts. Conclusions: PTRAS revascularization is an effective procedure for blood pressure control in renal vascular hypertension during one year follow up. (authors)

  12. The involvement of splenic artery in the blood supply of hepatomas: its DSA findings and interventional treatment

    International Nuclear Information System (INIS)

    Duan Xuhua; Liang Huiming; Feng Gansheng; Zheng Chuangsheng; Ren Jianzhuang

    2009-01-01

    Objective: To investigate the DSA manifestations of the involvement of splenic artery in supplying blood to hepatomas and to assess the therapeutic value of super-selective interventional embolization. Methods: During the period of March 2005-June 2008, 897 patients with hepatoma underwent angiography and the involvement of splenic artery in the blood supply of hepatoma was confirmed in 7 cases. Splenic arteriography was performed by means of super-selective catheterization with 5 F Yashiro catheter together with 3 F SP catheter. The splenic arteries which supplied blood to hepatomas were embolized with hyper-liquid iodized-oil emulsion mixed with chemotherapy drug, which was followed by the injection of sufficient gelatin sponge or ethanol. The clinical results were analyzed. Results: Splenic arteriography revealed that the splenic artery was the main supplying vessel of the hepatoma in two cases, and was not the main supplying vessel of the hepatoma in five cases. The splenic supplying vessels were completely embolized in all 7 cases. After the procedure, AFP level was decreased over 50%, and in two patients it dropped to normal. CT checkup 4-6 weeks after the surgery revealed that the diameter of tumor decreased to 2.5 - 4.6 cm. Conclusion: The involvement of splenic artery in supplying blood to hepatomas is not common. Super-selective catheterization and sufficient embolization of the splenic supplying vessels are very important for improving the interventional effectiveness. (authors)

  13. Effects of iodinated contrast media on common carotid and brachial artery blood flow and wall shear stress

    International Nuclear Information System (INIS)

    Irace, C.; Tamburini, S.; Bertucci, B.; Franceschi, M.S. de; Gnasso, A.

    2006-01-01

    The aim of our study was to evaluate the effect of the intravenous contrast media iomeprol on wall shear stress, blood flow and vascular parameters in the common carotid and brachial artery. Thirty outpatients undergoing thoracic or abdominal spiral CT scans were studied. The internal diameter and flow velocity of the common carotid and brachial artery were evaluated by ultrasound, and blood viscosity was measured before and after low osmolality iomeprol (Iomeron 350) injection. The wall shear stress, blood flow and pulsatility index were calculated. To test the differences between groups, the Wilcoxon rank test and Mann Whitney U test were applied. Blood viscosity decreased slightly, but significantly after contrast media (4.6±0.7 vs. 4.5±0.7 mPa.s, P=0.02). Contrarily, blood flow and wall shear stress did not change in the common carotid artery, but significantly decreased in the brachial artery (0.9±0.4 vs. 0.6±0.3 ml/s, P<0.0001, and 41.5±13.9 vs. 35.3±11.0 dynes/cm2, P<0.002, respectively), whereas the pulsatility index significantly increased in the brachial artery (5.0±3.3 vs. 7.5±5.3, P<0.001). Iomeprol injection causes blood flow and wall shear stress reduction of the brachial artery; the rise in the pulsatility index suggests an increase in peripheral vascular resistance. Further investigation is needed to evaluate whether these modifications can be clinically relevant. (orig.)

  14. Continuous estimates of dynamic cerebral autoregulation: influence of non-invasive arterial blood pressure measurements

    International Nuclear Information System (INIS)

    Panerai, R B; Smith, S M; Rathbone, W E; Samani, N J; Sammons, E L; Bentley, S; Potter, J F

    2008-01-01

    Temporal variability of parameters which describe dynamic cerebral autoregulation (CA), usually quantified by the short-term relationship between arterial blood pressure (BP) and cerebral blood flow velocity (CBFV), could result from continuous adjustments in physiological regulatory mechanisms or could be the result of artefacts in methods of measurement, such as the use of non-invasive measurements of BP in the finger. In 27 subjects (61 ± 11 years old) undergoing coronary artery angioplasty, BP was continuously recorded at rest with the Finapres device and in the ascending aorta (Millar catheter, BP AO ), together with bilateral transcranial Doppler ultrasound in the middle cerebral artery, surface ECG and transcutaneous CO 2 . Dynamic CA was expressed by the autoregulation index (ARI), ranging from 0 (absence of CA) to 9 (best CA). Time-varying, continuous estimates of ARI (ARI(t)) were obtained with an autoregressive moving-average (ARMA) model applied to a 60 s sliding data window. No significant differences were observed in the accuracy and precision of ARI(t) between estimates derived from the Finapres and BP AO . Highly significant correlations were obtained between ARI(t) estimates from the right and left middle cerebral artery (MCA) (Finapres r = 0.60 ± 0.20; BP AO r = 0.56 ± 0.22) and also between the ARI(t) estimates from the Finapres and BP AO (right MCA r = 0.70 ± 0.22; left MCA r = 0.74 ± 0.22). Surrogate data showed that ARI(t) was highly sensitive to the presence of noise in the CBFV signal, with both the bias and dispersion of estimates increasing for lower values of ARI(t). This effect could explain the sudden drops of ARI(t) to zero as reported previously. Simulated sudden changes in ARI(t) can be detected by the Finapres, but the bias and variability of estimates also increase for lower values of ARI. In summary, the Finapres does not distort time-varying estimates of dynamic CA obtained with a sliding window combined with an ARMA model

  15. Effect of Familiar Olfactory Stimulus on Responses to Blood Sampling Pain in Neonates

    Directory of Open Access Journals (Sweden)

    A. Sadathosseini

    2011-04-01

    Full Text Available Introduction & Objective: Pain in neonates can lead to various risks. So, it seems essential to find a simple, safe, and acceptable method for relieving pain. The objective of this study was to assess the effectiveness of olfactory stimuli (familiar and unfamiliar on physiological and behavioral responses to the pain of arterial blood draws in term neonates. Materials & Methods: In this quasi-experimental clinical trial, according to the conditions of the study 135 term neonates were chosen by convenience sampling and were assigned to three groups. During the procedure, familiar odor group was presented with the vanilla smell with which they had been familiarized prior to the procedure for 9 hours. Unfamiliar odor group was presented with the vanilla smell to which they had not been previously exposed, and the control group was presented with no odor. The heart rate and O2 saturation levels were measured before, after inserting and after removing the needle. Also, their cry duration was measured from onset until a crying free interval of more than five seconds. Results: The infants exposed to the familiar odor cried significantly less during the procedure compared to the unfamiliar odor and no odor group (P<0.001. Moreover, there was no statistically significant difference in the heart rate among the groups after inserting and removing the needle and in the O2 saturation rate after inserting the needle. The O2 saturation rate was significantly higher in the familiar odor group compared with the other groups (p<0.05 after the needle removal. Conclusion: A familiar odor is effective in reducing crying during arterial blood draws in neonates, but does not affect on physiological parameters. (Sci J Hamadan Univ Med Sci 2011;18(1:10-19

  16. Demonstration of blood flow by color doppler in the femoral artery distal to arterial cannula during peripheral venoarterial-extracorporeal membrane oxygenation

    Directory of Open Access Journals (Sweden)

    K G Suresh Rao

    2017-01-01

    Full Text Available In spite of distal perfusion of the limb using a cannula, the limb can have ischemic events if there is an undetected kink or clot anywhere in the line or thrombus in the artery. There are several ways to monitor and assess the limb ischemia. Monitoring for clinical signs of limb ischemia like temperature change and pallor is reliable and mandatory. We report a method where we used color Doppler to document the blood flow. Curvilinear vascular probe of an echo machine is used to identify the flow in the distal femoral artery of the lower limb. . As we have demonstrated in the video attached, once flow to the distal limb perfusion system is shut off by closing the three way stop cock, we can appreciate the immediate cessation of flow in the artery by Doppler.

  17. Results of ambulatory arterial blood pressure monitoring in children with obesity

    Directory of Open Access Journals (Sweden)

    Faruk Öktem

    2010-12-01

    Full Text Available Objectives: The relationship between obesity and essential hypertension is well known. In this study, we aimed to evaluate ambulatory arterial blood pressure monitoring of obese and non-obese children who had similar demographic characteristics.Materials and methods: Seventy one children and adolescents (n=39 obesity, n=32 controls were studied. Blood pressure of the children were measured by 24 hour ambulatory blood pressure monitoring device.Results: Obese children had significantly higher mean blood pressure values (systolic 121.9±11.7 mmHg, diastolic 70.2±5.3 mmHg than control subjects (systolic 109.3±6.7 mmHg, diastolic 65.1±4.6 mmHg, p0.05. Blood pressure load was found to be increased in obese children compared to the controls (%13.6±12.9 and %2.6±3.4, respectively; p<0.05. Serum total cholesterol and LDL-cholesterol levels of obese children (181.1±33.4 and 131.1±23.1mg/dl were significantly higher than those of the controls (134.3±11.1 and 103.3±14.2 mg/dl, p<0.05.Conclusions: Obesity in children and adolescents should not be regarded as variations of normality, but as abnormality with an extremely high risk for the development of hypertension and hyperlipidemia in adulthood.

  18. Association of sleep duration with arterial blood pressure profile of Gujarati Indian adolescents

    Directory of Open Access Journals (Sweden)

    Shaikh Wasim

    2010-01-01

    Full Text Available Background and Aim: Recently, National Health and Nutritional Examination Survey-1 data analysis found short sleep duration as a risk factor for hypertension in the U.S. population. However, since ethnic differences exist in the aetiopathogenesis of diseases, the current study was undertaken to study the effect of sleep duration on the blood pressure profile of Gujarati Indian adolescents. Materials and Methods: A cross-sectional study was conducted on 489 Gujarati Indian adolescents of age group 16-19 years studying in school and colleges in the local population. The participants were assessed for their sleep duration, physical activity status, body composition, blood pressure profile and cardiovascular reactivity. The sleep duration was reported by the subjects as the number of hours they slept on most of the nights in a week over the last one year. The observations of the study were then analyzed after grouping them into: 1 Adequate Sleep Duration at Night, ASDN (≥ 7 hrs and 2 Inadequate Sleep Duration at Night, ISDN (< 7 hrs groups. Student′s unpaired t-test was used to study if any significant difference (P< 0.05 existed between the groups. Results: No significant difference was found in Systolic blood pressure, Diastolic blood pressure, Pulse pressure and Mean arterial pressure between the ASDN group and the ISDN group. Physical activity status also did not differ between the two groups. However, adolescents of ISDN group showed a significantly higher level of adiposity and cardiovascular reactivity as compared to adolescents of ASDN group. Conclusion: Although short sleep duration is associated with a higher level of adiposity and cardiovascular reactivity in Gujarati Indian adolescents, it does not affect the resting blood pressure profile of these adolescents. However, longitudinal studies would be required to observe if the changes in adiposity and cardiovascular reactivity affect these adolescents in later life.

  19. Contribution of the Arterial System and the Heart to Blood Pressure during Normal Aging - A Simulation Study.

    Science.gov (United States)

    Maksuti, Elira; Westerhof, Nico; Westerhof, Berend E; Broomé, Michael; Stergiopulos, Nikos

    2016-01-01

    During aging, systolic blood pressure continuously increases over time, whereas diastolic pressure first increases and then slightly decreases after middle age. These pressure changes are usually explained by changes of the arterial system alone (increase in arterial stiffness and vascular resistance). However, we hypothesise that the heart contributes to the age-related blood pressure progression as well. In the present study we quantified the blood pressure changes in normal aging by using a Windkessel model for the arterial system and the time-varying elastance model for the heart, and compared the simulation results with data from the Framingham Heart Study. Parameters representing arterial changes (resistance and stiffness) during aging were based on literature values, whereas parameters representing cardiac changes were computed through physiological rules (compensated hypertrophy and preservation of end-diastolic volume). When taking into account arterial changes only, the systolic and diastolic pressure did not agree well with the population data. Between 20 and 80 years, systolic pressure increased from 100 to 122 mmHg, and diastolic pressure decreased from 76 to 55 mmHg. When taking cardiac adaptations into account as well, systolic and diastolic pressure increased from 100 to 151 mmHg and decreased from 76 to 69 mmHg, respectively. Our results show that not only the arterial system, but also the heart, contributes to the changes in blood pressure during aging. The changes in arterial properties initiate a systolic pressure increase, which in turn initiates a cardiac remodelling process that further augments systolic pressure and mitigates the decrease in diastolic pressure.

  20. Numerical analysis of blood flow in realistic arteries subjected to strong non-uniform magnetic fields

    International Nuclear Information System (INIS)

    Kenjeres, Sasa

    2008-01-01

    The paper reports on a comprehensive mathematical model for simulations of blood flow under the presence of strong non-uniform magnetic fields. The model consists of a set of Navier-Stokes equations accounting for the Lorentz and magnetisation forces, and a simplified set of Maxwell's equations (Biot-Savart/Ampere's law) for treating the imposed magnetic fields. The relevant hydrodynamic and electromagnetic properties of human blood were taken from the literature. The model is then validated for different test cases ranging from a simple cylindrical geometry to real-life right-coronary arteries in humans. The time-dependency of the wall-shear-stress for different stenosis growth rates and the effects of the imposed strong non-uniform magnetic fields on the blood flow pattern are presented and analysed. It is concluded that an imposed non-uniform magnetic field can create significant changes in the secondary flow patterns, thus making it possible to use this technique for optimisations of targeted drug delivery

  1. Association of vitamin D status with arterial blood pressure and hypertension risk

    DEFF Research Database (Denmark)

    Vimaleswaran, Karani S; Cavadino, Alana; Berry, Diane J

    2014-01-01

    BACKGROUND: Low plasma 25-hydroxyvitamin D (25[OH]D) concentration is associated with high arterial blood pressure and hypertension risk, but whether this association is causal is unknown. We used a mendelian randomisation approach to test whether 25(OH)D concentration is causally associated...... with blood pressure and hypertension risk. METHODS: In this mendelian randomisation study, we generated an allele score (25[OH]D synthesis score) based on variants of genes that affect 25(OH)D synthesis or substrate availability (CYP2R1 and DHCR7), which we used as a proxy for 25(OH)D concentration. We meta......, -0·12 mm Hg, 95% CI -0·20 to -0·04; p=0·003) and reduced odds of hypertension (odds ratio [OR] 0·98, 95% CI 0·97-0·99; p=0·0003), but not with decreased diastolic blood pressure (β per 10% increase, -0·02 mm Hg, -0·08 to 0·03; p=0·37). In meta-analyses in which we combined data from D...

  2. Modeling and analysis of biomagnetic blood Carreau fluid flow through a stenosis artery with magnetic heat transfer: A transient study.

    Science.gov (United States)

    Abdollahzadeh Jamalabadi, Mohammad Yaghoub; Daqiqshirazi, Mohammadreza; Nasiri, Hossein; Safaei, Mohammad Reza; Nguyen, Truong Khang

    2018-01-01

    We present a numerical investigation of tapered arteries that addresses the transient simulation of non-Newtonian bio-magnetic fluid dynamics (BFD) of blood through a stenosis artery in the presence of a transverse magnetic field. The current model is consistent with ferro-hydrodynamic (FHD) and magneto-hydrodynamic (MHD) principles. In the present work, blood in small arteries is analyzed using the Carreau-Yasuda model. The arterial wall is assumed to be fixed with cosine geometry for the stenosis. A parametric study was conducted to reveal the effects of the stenosis intensity and the Hartman number on a wide range of flow parameters, such as the flow velocity, temperature, and wall shear stress. Current findings are in a good agreement with recent findings in previous research studies. The results show that wall temperature control can keep the blood in its ideal blood temperature range (below 40°C) and that a severe pressure drop occurs for blockages of more than 60 percent. Additionally, with an increase in the Ha number, a velocity drop in the blood vessel is experienced.

  3. Measurement of brachial artery endothelial function using a standard blood pressure cuff

    International Nuclear Information System (INIS)

    Maltz, Jonathan S; Budinger, Thomas F; Tison, Geoffrey H; Olgin, Jeffrey; Alley, Hugh F; Owens, Christopher D

    2015-01-01

    The integrity of endothelial function in major arteries (EFMA) is a powerful independent predictor of heart attack and stroke. Existing ultrasound-based non-invasive assessment methods are technically challenging and suitable only for laboratory settings. EFMA, like blood pressure (BP), is both acutely and chronically affected by factors such as lifestyle and medication. Consequently, laboratory-based measurements cannot fully gauge the effects of medical interventions on EFMA. EFMA and BP have, arguably, comparable (but complementary) value in the assessment of cardiovascular health. Widespread deployment of EFMA assessment is thus a desirable clinical goal. To this end, we propose a device based on modifying the measurement protocol of a standard electronic sphygmomanometer. The protocol involves inflating the cuff to sub-diastolic levels to enable recording of the pulse waveform before and after vasodilatory stimulus. The mechanical unloading of the arterial wall provided by the cuff amplifies the distension that occurs with each pulse, which is measured as a pressure variation in the cuff. We show that the height of the rising edge of each pulse is proportional to the change in lumen area between diastole and systole. This allows the effect of vasodilatory stimuli on the artery to be measured with high sensitivity. We compare the proposed cuff flow-mediated dilation (cFMD) method to ultrasound flow-mediated dilation (uFMD). We find significant correlation (r  =  0.55, p  =0.003, N  =  27) between cFMD- and uFMD-based metrics obtained when the release of a 5 min cuff occlusion is employed to induce endothelial stimulus via reactive hyperemia. cFMD is approximately proportional to the square of uFMD, representing a typical increase in sensitivity to vasodilation of 300–600%. This study illustrates the potential for an individual to conveniently measure his/her EFMA by using a low-cost reprogrammed home sphygmomanometer. (paper)

  4. Continuous determination of regional myocardial blood flow with intracoronary krypton-81m in coronary artery disease

    International Nuclear Information System (INIS)

    Remme, W.J.; Krauss, X.H.; van Hoogenhuyze, D.C.; Cox, P.H.; Storm, C.J.; Kruyssen, D.A.

    1985-01-01

    Pacing-induced changes in regional coronary flow were studied continuously with krypton-81m by intracoronary infusion in 25 patients: 21 with 50% or greater diameter narrowing of 1 or more left coronary arteries (group I) and 4 with less than 50% diameter reduction of a left coronary artery (group II). No changes occurred in group II. In group I, krypton-81m perfusion decreased progressively in all areas with more than 70% diameter narrowing, with a simultaneous increase in normal regions. At the end of pacing during angina, krypton-81m perfusion was reduced to 81 +/- 4% of control in areas with 71 to 90% diameter reduction (n = 8) and to 69 +/- 6% in areas with more than 90% diameter narrowing (n = 15). In contrast, in regions with 50 to 70% diameter reduction changes were variable (decrease in 4 regions, increase in 2 and an unchanged distribution in 1 region). Krypton-81m perfusion decreased early, before general signs of ischemia in areas with more than 90% diameter reduction, whereas this decrease occurred later in regions with 71 to 90% diameter narrowing, concurrently with ST-segment changes but before anginal pain. Although all signs of ischemia had disappeared between 2 and 5 minutes after pacing, changes in krypton-81m distribution persisted in most areas for 5 to 15 minutes after pacing. It is concluded that the functional significance of coronary arterial narrowing can be assessed with a continuous intracoronary infusion of krypton-81m. Changes in regional distribution persisted after cessation of pacing-induced ischemia, indicating an ongoing decrease in regional myocardial blood flow

  5. Predictors of arterial blood pressure control during deliberate hypotension with sodium nitroprusside in children.

    Science.gov (United States)

    Spielberg, David R; Barrett, Jeffrey S; Hammer, Gregory B; Drover, David R; Reece, Tammy; Cohane, Carol A; Schulman, Scott R

    2014-10-01

    Sodium nitroprusside (SNP) is used to decrease arterial blood pressure (BP) during certain surgical procedures. There are limited data regarding efficacy of BP control with SNP. There are no data on patient and clinician factors that affect BP control. We evaluated the dose-response relationship of SNP in infants and children undergoing major surgery and performed a quantitative assessment of BP control. One hundred fifty-three subjects at 7 sites received a blinded infusion followed by open-label SNP during operative procedures requiring controlled hypotension. SNP was administered by continuous infusion and titrated to maintain BP control (mean arterial BP [MAP] within ±10% of clinician-defined target). BP was recorded using an arterial catheter. Statistical process control methodology was used to quantify BP control. A multivariable model assessed the effects of patient and procedural factors. BP was controlled an average 45.4% (SD 23.9%; 95% CI, 41.5%-49.18%) of the time. Larger changes in infusion rate were associated with worse BP control (7.99% less control for 1 μg·kg·min increase in average titration size, P = 0.0009). A larger difference between a patient's baseline and target MAP predicted worse BP control (0.93% worse control per 1-mm Hg increase in MAP difference, P = 0.0013). Both effects persisted in multivariable models. SNP was effective in reducing BP. However, BP was within the target range less than half of the time. No clinician or patient factors were predictive of BP control, although 2 inverse relationships were identified. These relationships require additional study and may be best coupled with exposure-response modeling to propose improved dosing strategies when using SNP for controlled hypotension in the pediatric population.

  6. Automatic collection of bovine blood samples | Hale | South African ...

    African Journals Online (AJOL)

    A technique is described which allows automatic collection of jugular venous blood from tethered cows. In this system, blood is pumped continuously from an intravenous cannula which has a double lumen while an anticoagulant is pumped through the second opening. Diluted blood is collected in a fraction collector which ...

  7. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results.

    Science.gov (United States)

    Sulaiman, Raashda A; Cornes, Michael P; Whitehead, Simon J; Othonos, Nadia; Ford, Clare; Gama, Rousseau

    2011-11-01

    To investigate whether incorrect order of draw of blood samples during phlebotomy causes in vitro potassium ethylenediaminetetraacetic acid EDTA (kEDTA) contamination of blood samples. Serum kEDTA, potassium, calcium, magnesium, alkaline phosphatase, zinc and iron concentrations were measured in blood samples drawn before and after collecting blood into kEDTA containing sample tubes by an experienced phlebotomist using the Sarstedt Safety Monovette system. EDTA was undetectable in all samples. The concentrations of other analytes were similar in blood samples drawn before and after collection of the EDTA blood sample. Order of draw of blood samples using the Sarstedt Safety Monovette system has no effect on serum biochemistry results, when samples are taken by an experienced phlebotomist.

  8. Maternal Body Mass Index Does Not Affect Neonatal Umbilical Artery Blood Gas Parameters

    Directory of Open Access Journals (Sweden)

    Salam E. Chalouhi

    2013-01-01

    Full Text Available This study was undertaken to assess the impact of obesity on fetal well-being in glucose-tolerant and nonhypertensive women. Medical charts of all patients admitted to the labor and delivery department at our institution between January, 2011 and July, 2011 were retrospectively reviewed. Patients with diabetes/impaired glucose tolerance or hypertension were excluded. A total of 100 women, 50 lean and 50 obese, were included. Umbilical artery blood gas parameters (BGPs were compared in lean (<25 kg/m2 and obese (≥30 kg/m2 women. Obese and lean women were comparable with respect to all baseline characteristics. There was no difference in any of the BGP or Apgar scores between obese and lean patients. Pearson’s correlation coefficient found no significant correlation between BMI and BGP/Apgar scores. Maternal obesity does not seem to affect BGP and fetal well-being in glucose-tolerant and nonhypertensive women.

  9. Utilization of arterial blood gas measurements in a large tertiary care hospital.

    Science.gov (United States)

    Melanson, Stacy E F; Szymanski, Trevor; Rogers, Selwyn O; Jarolim, Petr; Frendl, Gyorgy; Rawn, James D; Cooper, Zara; Ferrigno, Massimo

    2007-04-01

    We describe the patterns of utilization of arterial blood gas (ABG) tests in a large tertiary care hospital. To our knowledge, no hospital-wide analysis of ABG test utilization has been published. We analyzed 491 ABG tests performed during 24 two-hour intervals, representative of different staff shifts throughout the 7-day week. The clinician ordering each ABG test was asked to fill out a utilization survey. The most common reasons for requesting an ABG test were changes in ventilator settings (27.6%), respiratory events (26.4%), and routine (25.7%). Of the results, approximately 79% were expected, and a change in patient management (eg, a change in ventilator settings) occurred in 42% of cases. Many ABG tests were ordered as part of a clinical routine or to monitor parameters that can be assessed clinically or through less invasive testing. Implementation of practice guidelines may prove useful in controlling test utilization and in decreasing costs.

  10. Dependency of cerebral blood flow upon mean arterial pressure in patients with acute bacterial meningitis

    DEFF Research Database (Denmark)

    Møller, Kirsten; Larsen, Fin Stolze; Qvist, Jesper

    2000-01-01

    Diseases, Copenhagen University Hospital, Denmark. PATIENTS: Sixteen adult patients with acute bacterial meningitis. INTERVENTION: Infusion of norepinephrine to increase MAP. MEASUREMENTS: During a rise in MAP induced by norepinephrine infusion, we measured relative changes in CBF by transcranial Doppler......OBJECTIVE: Patients with acute bacterial meningitis are often treated with sympathomimetics to maintain an adequate mean arterial pressure (MAP). We studied the influence of such therapy on cerebral blood flow (CBF). DESIGN: Prospective physiologic trial. SETTING: The Department of Infectious....... Autoregulation was classified as impaired if Vmean increased by >10% per 30 mm Hg increase in MAP and if no lower limit of autoregulation was identified by the computer program; otherwise, autoregulation was classified as preserved. MAIN RESULTS: Initially, Vmean increased from a median value of 46 cm/sec (range...

  11. Blood flow of the right and left submandibular gland during unilateral carotid artery occlusion in rat: role of nitric oxide.

    Science.gov (United States)

    Vág, J; Hably, C; Fazekas, A; Bartha, J

    1999-01-01

    The aim of the present study was to investigate the effect of unilateral carotid artery occlusion on the blood flow of submandibular gland in anesthetized rats and identify the role of nitric oxide (NO) in blood flow changes after the artery occlusion. L-NAME (N omega-nitro-L-arginine-methyl-ester; 10 mg/kg/day, per os) dissolved in tap water was used to block nitric oxide synthase. Glandular blood flow was measured using Sapirstein's indicator (86Rb) distribution technique. In the control animals the blood flow of left (ligated side) submandibular gland was lower than in the right (unligated side) one (right: 76.4+/-15.4 ml/min/100 g, 64.1+/-13.4 ml/min/100 g, ptinder this condition.

  12. Measurement of stenotic rate and blood flow of carotid artery of the dogs with digital subtraction angiography

    International Nuclear Information System (INIS)

    Kobayashi, Keisuke; Kagawa, Masaaki; Asai, Masaaki; Yasue, Hiroshi; Kawabata, Kazuhiro; Yue, Shuzengmr

    1987-01-01

    Hemodynamic analysis of stenotic rate and local mean blood flow of the common carotid artery of the dogs with electromagnetic flowmeter and DSA was evaluated. Measurement of stenotic rate using local profile curve was very accurate and it was though to be useful in evaluation of local blood flow of the cervical carotid artery in the patients with carotid stenosis pre-and postoperatively. Although the measurement of absolute blood flow in the case of known diameter of the vessel is exactly reliable, the measured flow is not so reliable in the clinical application for the difficulty in the accurate measurement of the diameter. But hemodynamic analysis of the relative blood flow in the clinical ground can be estimated from this study. The theory and practical measurement are discussed. (author)

  13. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi, E-mail: k-takano@fukuoka-u.ac.jp; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-15

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  14. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    International Nuclear Information System (INIS)

    Takano, Koichi; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-01

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  15. EFFECT OF ADDING THE INTERNAL STANDARD TO BLOOD SAMPLES, PRIOR TO THE PREPARATION OF BLOOD SPOTS FOR ACYLCARNITINE ANALYSIS

    OpenAIRE

    Osorio, José Henry; Pourfarzam, Morteza

    2010-01-01

    Background: some general factors can influence when determining acylcarnitines through tandem mass spectrometry. Objective: to study the effect of adding the internal standard to blood samples before the preparation of filter paper cards compared with the addition of internal standard after having the filter paper cards prepared for determining acylcarnitines in blood for tandem mass spectrometry. Methodology: two groups of blood samples were prepared: group one without adding internal standa...

  16. Renal embolic protection devices improve blood flow after stenting for atherosclerotic renal artery stenosis.

    Science.gov (United States)

    Paul, Timir K; Lee, John H; White, Christopher J

    2012-11-15

    We sought to measure angiographic renal frame counts (RFC), as a quantitative angiographic assessment of renal blood flow, to evaluate microvascular compromise due to atheroembolism associated with RAS. Atheroembolism associated with renal artery stenting (RAS) has been implicated as a cause for worsening renal function following successful intervention. Use of a distal embolic protection device (EPD) during RAS has been shown to be safe with debris capture in a high percentage of cases. However, objective benefit for renal function with EPD has been difficult to demonstrate. A control group of 30 consecutive patients (33 kidneys) who underwent RAS without EPD were compared with 33 consecutive patients (33 kidneys) who underwent RAS with EPD using RFC measurement. The prestent and poststent mean RFC for the control group was 30.4 ± 12.1 vs. 23.7 ± 9.9 (P = 0.002) and for the EPD group it was 42.6 ± 12.6 vs. 28.3 ± 9.2 (P renal blood flow, manifested by a greater reduction of the RFC (Δ RFC) 14.2 ± 15.2 vs. 6.7 ± 11.7 (P = 0.03) compared with the control group. The use of an EPD was associated with a much larger improvement in renal blood flow (lower RFC) following RAS. This suggests that EPD's may be effective in preventing renal atheroembolic injury and that a controlled trial measuring the impact of EPD's on renal blood flow following RAS should be performed. Copyright © 2012 Wiley Periodicals, Inc.

  17. Mini-cardiopulmonary bypass impact on blood conservation strategy in coronary artery bypass grafting.

    Science.gov (United States)

    Abdel Aal, Mohamed; ElNahal, Nezar; Bakir, Bakir Moustafa; Fouda, Mohamed

    2011-04-01

    Cardiopulmonary bypass (CPB) using a closed circuit system with minimal priming volume can be a solution to ameliorate adverse effects of CPB. We hypothesize that the use of mini-bypass in routine coronary artery bypass grafting (CABG) reduces homologous blood product use and postoperative bleeding. The study is designed to determine the differences in blood loss and transfusion requirements associated with a minimized CPB circuit vs. a standard bypass circuit. From February 2009 to August 2009, 80 patients were prospectively randomized to undergo elective CABG. Group A included 40 patients who had the minimized bypass circuit (Medtronic Resting Heart Circuit). Group B had an equal number of patients who had the standard CPB circuit (Stockert III, SEC.BM). Laboratory parameters for hemoglobin, hematocrit and platelet count were measured at baseline after initiation of CPB and after bypass. Blood usage was controlled by study-specific protocol (transfusion for hemoglobin platelets (1.95±2.95 units vs. 3.23±2.85), and postoperative drainage in 24 hours (531.62±220.12 ml vs. 729±294.9 ml, P<0.05). The hematocrit was 33±5% in group A, and 27±1% in group B. There was statistical differences seen in the mean hemoglobin level which was 10.19±0.65 g/dl in group A, and 9.4±0.68 g/dl in group B. There was statistical difference in the duration of ventilation, length of ICU stay. The requirement of inotropic support was lower in group A. The adoption of mini-bypass significantly reduces morbidity including donor blood usage and postoperative bleeding in routine CABG patients.

  18. The stability of arterial blood gases during transportation of patients using the RespirTech PRO.

    Science.gov (United States)

    Romano, M; Raabe, O G; Walby, W; Albertson, T E

    2000-05-01

    The transportation of critically ill patients requiring mechanical ventilation is recognized as a high-risk and expensive procedure. Approaches have included using manual bag-type valve resuscitators and expensive portable transport ventilators. This study evaluated the effectiveness of the inexpensive portable RespirTech PRO (RTP) gas-powered automatic resuscitator during intrahospital transport of critically ill mechanically ventilated patients. Twenty medical intensive care patients on stable mechanical ventilator settings had arterial blood gas and vital sign determination before routine transport out of the intensive care unit (ICU). Repeat measurements were made during transport approximately 30 minutes after being placed on the RTP portable pressure-cycled automatic resuscitator using an FiO2 of 100%. During use of the RTP for transport, there were no statistically significant variations observed in mean arterial blood pressure [82 +/- 11 SD (range 65 to 112) mm Hg before transport versus 85 +/- 14 SD (range 59 to 110) mm Hg during transport], heart rate [94 +/- 16 SD (range 74 to 127) beats/min) before versus 96 +/- 17 SD (range 69 to 132) beats/min during], arterial pH [7.41 +/- 0.07 SD (range 7.31 to 7.58) before versus 7.42 +/- 0.05 SD (range 7.37 to 7.52) during], and PaCO2 [43 +/- 10 SD (range 26 to 65) mm Hg before versus 43 +/- 10 SD (range 27 to 61 mm Hg) during]. Because the FiO2 before transport was 63 +/- 26 SD (range 30% to 100%) versus 100% during transport using the RTP, the mean PaO2 was significantly increased from 124 +/- 86 SD (range 57 to 367) mm Hg before transport to 297 +/- 168 SD (range 65 to 537) mm Hg during (P< .001). No transportation associated clinical adverse events were noted. Several previous investigations have shown that portable ventilators are safe and effective in intrahospital transport of mechanically ventilated patients. This study showed that the portable pressure-cycled RTP also allows safe transportation of

  19. Decreased muscle oxygenation and increased arterial blood flow in the non-exercising limb during leg exercise.

    Science.gov (United States)

    Shiroishi, Kiyoshi; Kime, Ryotaro; Osada, Takuya; Murase, Norio; Shimomura, Kousuke; Katsumura, Toshihito

    2010-01-01

    We evaluated arterial blood flow, muscle tissue oxygenation and muscle metabolism in the non-exercising limb during leg cycling exercise. Ten healthy male volunteers performed a graded leg cycling exercise at 0, 40, 80, 120 and 160 watts (W) for 5 min each. Tissue oxygenation index (TOI) of the non-exercising left forearm muscle was measured using a near-infrared spatially resolved spectroscopy (NIR(SRS)), and non-exercising forearm blood flow ((NONEX)FBF) in the brachial artery was also evaluated by a Doppler ultrasound system. We also determined O(2) consumption of the non-exercising forearm muscle (NONEXV(O)(2mus)) by the rate of decrease in O(2)Hb during arterial occlusion at each work rate. TOI was significantly decreased at 160 W (p exercising muscle may be reduced, even though (NONEX)FBF increases at high work rates during leg cycling exercise.

  20. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure......Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  1. Mean blood velocities and flow impedance in the fetal descending thoracic aortic and common carotid artery in normal pregnancy.

    Science.gov (United States)

    Bilardo, C M; Campbell, S; Nicolaides, K H

    1988-12-01

    A linear array pulsed Doppler duplex scanner was used to establish reference ranges for mean blood velocities and flow impedance (Pulsatility Index = PI) in the descending thoracic aorta and in the common carotid artery from 70 fetuses in normal pregnancies at 17-42 weeks' gestation. The aortic velocity increased with gestation up to 32 weeks, then remained constant until term, when it decreased. In contrast, the velocity in the common carotid artery increased throughout pregnancy. The PI in the aorta remained constant throughout pregnancy, while in the common carotid artery it fell steeply after 32 weeks. These results suggest that with advancing gestation there is a redistribution of the fetal circulation with decreased impedance to flow to the fetal brain, presumably to compensate for the progressive decrease in fetal blood PO2.

  2. Relationship between segmental thallium-201 uptake and regional myocardial blood flow in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Nichols, A.B.; Weiss, M.B.; Sciacca, R.R.; Cannon, P.J.; Blood, D.K.

    1983-01-01

    The relationship between the spatial distribution of thallium-201 in myocardial perfusion scintigrams and the distribution of left ventricular regional myocardial blood flow was examined in 25 patients undergoing coronary arteriography. Thallium-201 myocardial scintigrams were obtained after symptom-limited exercise and after a 4 hr delay. Regional myocardial blood flow was measured by the xenon-133 clearance method in patients at rest and during rapid atrial pacing to a double product comparable with that achieved during exercise stress testing. Patterns of regional thallium-201 activity and regional myocardial blood flow, recorded in similar left anterior oblique projections, were compared for left ventricular segments supplied by the left anterior descending (LAD) and left circumflex (CIRC) arteries. In 11 patients without significant lesions of the left coronary artery (group 1), thallium-201 was homogeneously distributed in the LAD and CIRC distributions in scintigrams taken during peak exercise; these scintigrams correspond to homogeneous regional myocardial blood flow in the LAD and CIRC regions during pacing-induced stress. In 14 patients with significant lesions of the left coronary artery (group 2), ratios of regional thallium-201 activity in the LAD and CIRC distributions of exercise scintigrams correlated well (r . .84) with ratios of regional myocardial blood flow measured during rapid pacing. Background subtraction altered the relationship between relative thallium-201 uptake and regional myocardial blood flow, causing overestimation of the magnitude of flow reduction on exercise scintigrams

  3. Utility of arterial blood gas, CBC, biochemistry and cardiac hormones as evaluation parameters of cardiovascular disease in nonhuman primates.

    Science.gov (United States)

    Nakayama, Shunya; Koie, Hiroshi; Kanayama, Kiichi; Katakai, Yuko; Ito-Fujishiro, Yasuyo; Sankai, Tadashi; Yasutomi, Yasuhiro; Ageyama, Naohide

    2018-06-11

    Cardiovascular disease (CVD) has a tremendous impact on the quality of life of humans. While experimental animals are valuable to medical research as models of human diseases, cardiac systems differ widely across various animal species. Thus, we examined a CVD model in cynomolgus monkeys. Laboratory primates are precious resources, making it imperative that symptoms of diseases and disorders are detected as early as possible. Thus, in this study we comprehensively examined important indicators of CVD in cynomolgus monkeys, including arterial blood gas, complete blood count (CBC), biochemistry, and cardiac hormones. The control group included 20 healthy macaques showing non-abnormal findings in screening tests, whereas the CVD group included 20 macaques with valvular disease and cardiomyopathy. An increase of red blood cell distribution width was observed in the CBC, indicating chronic inflammation related to CVD. An increase of HCO 3 was attributed to the correction of acidosis. Furthermore, development of the CVD model was supported by significant increases in natriuretic peptides. It is suggested that these results indicated a correlation between human CVD and the model in monkeys. Moreover, blood tests including arterial blood gas are non-invasive and can be performed more easily than other technical tests. CVD affected animals easily change their condition by anesthesia and surgical invasion. Pay attention to arterial blood gas and proper respond to their condition are important for research. This data may facilitate human research and aid in the management and veterinary care of nonhuman primates.

  4. Pressão arterial entre trabalhadores de curtume Blood pressure among tannery workers

    Directory of Open Access Journals (Sweden)

    Ricardo Cordeiro

    1998-10-01

    Full Text Available INTRODUÇÃO: O grupo das doenças cardiovasculares tem sido apontado como a principal causa de óbito no Brasil desde os anos 70, sendo a hipertensão arterial sistêmica (HAS o fator de risco mais importante para esse grupo. Entre os trabalhadores observa-se correlação negativa entre o status ocupacional e a pressão arterial. Tais fatos ressaltam a importância do conhecimento da distribuição da pressão arterial sistêmica entre os distintos grupos profissionais. Assim, foi realizado estudo para descrever o status pressórico de uma população homogênea e estável de trabalhadores do setor secundário da economia, pouco especializados e que ganham baixos salários, estabelecendo a prevalência da HAS nesse grupo específico, relacionando-a com algumas covariáveis biológicas e socioeconômicas, e comparando-a com a prevalência de HAS em outros grupos profissionais no Brasil. MÉTODO: Foram estudados 73 trabalhadores regularmente empregados em julho de 1993 em um curtume situado no Município de Botucatu, cidade de médio porte da região Centro-Oeste do Estado de São Paulo, os quais foram submetidos a exame antropométrico, aferição de pressão arterial, anamnese e exame clínico. Os resultados foram comparados com os obtidos em estudos semelhantes, controlando-se o confundimento da idade por intermédio de diferentes técnicas. RESULTADOS: A prevalência bruta da HAS encontrada foi de 56,1%, sendo 15,8% a prevalência de hipertensão sistólica isolada. Ambas se associaram ao etilismo e ao tabagismo na população estudada. DISCUSSÃO: A prevalência da hipertensão foi consideravelmente alta e significativamente maior do que a encontrada em outros grupos de trabalhadores estudados no Brasil. Tal achado ressalta a necessidade da continuidade da investigação, objetivando o isolamento dos fatores implicados na elevação pressórica do grupo estudado.INTRODUCTION: Cardiovascular diseases have been shown to be the leading cause of

  5. Effects of sodium and potassium supplementation on blood pressure and arterial stiffness: a fully controlled dietary intervention study

    NARCIS (Netherlands)

    Gijsbers, L.; Dower, J.I.; Mensink, M.R.; Siebelink, A.E.; Bakker, S.J.L.; Geleijnse, J.M.

    2015-01-01

    We performed a randomised, placebo-controlled, crossover study to examine the effects of sodium and potassium supplementation on blood pressure (BP) and arterial stiffness in untreated (pre)hypertensive individuals. During the study, subjects were on a fully controlled diet that was relatively low

  6. Studies on blood supply of liver metastasis with DSA, CT and portal vein perfusion CT during superior mesenteric arterial portography

    International Nuclear Information System (INIS)

    Li Zhigang; Shi Gaofeng; Huang Jingxiang; Li Shunzong; Liang Guoqing; Wang Hongguang; Han Pengyin; Wang Qi; Gu Tieshu

    2008-01-01

    Objective: To probe the blood supply of liver metastasis by celiac artery, proper hepatic artery DSA, portal vein perfusion CT during superior mesenteric arterial portography (PCTAP). Methods: One hundred patients with liver metastases were examined prospectively by plain CT scan, multiphase enhanced CT scan, celiac arteriography and proper hepatic arteriography. Of them, 56 patients were examined by PCTAP. All primary lesions were confirmed by operation and (or) pathology examination. In order to investigate the blood supply of metastasis lesions, the software of Photoshop was used to obtain the time-attenuation curves (TDC) of tumor center, tumor edge, portal vein and normal liver parenchyma adjacent to the tumor to calculate liver perfusion for DSA image analysis, while a deconvolution model from CT perfusion software was designed for the dual blood supply. Results: DSA findings: TDC of proper hepatic arteriography showed: the mean peak concentration (K value) in tumor centers was (67 ± 12)%, and it was (76 ± 15)% for peritumor tissue, (51 ± 10)% in normal liver parenchyma. TDC of celiac arteriogaphy showed that the contrast concentration of tumor centers and tumor edge increased fast in early stage, then maintained a slight upward plateau, in the meanwhile, the contrast concentration of normal liver parenchyma kept increasing slowly. PCTAP findings: tumors exhibited no enhancement during 30 s continued scans. Conclusion: The blood supply of liver metastasis mainly comes from hepatic artery, but barely from portal vein. (authors)

  7. Changes in distribution of hepatic blood flow induced by intra-arterial infusion of angiotensin II in human hepatic cancer

    International Nuclear Information System (INIS)

    Sasaki, Y.; Imaoka, S.; Hasegawa, Y.

    1985-01-01

    Changes in the distribution of the hepatic blood flow induced by intra-arterial infusion of angiotensin II (AT-II) were studied in human hepatic cancers using extremely short-lived radioisotope (RI) (krypton 81 m [/sup 81m/Kr]; half-life, 13 seconds). After the start of continuous infusion of AT-II, the radioactivity of the tumor showed about a two-fold increase, whereas that of the nontumor region decreased to about one half as much as the level before the infusion. Consequently, the mean ratio of the arterial blood flow in the tumor region to that in the nontumor region (T/N ratio) increased to 3.30 (P less than 0.001). The T/N ratio showed a peak before the peripheral blood pressure reached the maximum, and thereafter tended to decrease. Intra-arterial infusion of AT-II raised the T/N ratio more obviously than did intravenous infusion of the drug, with less rise in the peripheral blood pressure. It is believed that intra-arterial infusion chemotherapy with local use of AT-II enables better accessibility of chemotherapeutic drugs to tumors

  8. The relationship between exercise-induced muscle fatigue, arterial blood flow and muscle perfusion after 56 days local muscle unloading.

    Science.gov (United States)

    Weber, Tobias; Ducos, Michel; Mulder, Edwin; Beijer, Åsa; Herrera, Frankyn; Zange, Jochen; Degens, Hans; Bloch, Wilhelm; Rittweger, Jörn

    2014-05-01

    In the light of the dynamic nature of habitual plantar flexor activity, we utilized an incremental isokinetic exercise test (IIET) to assess the work-related power deficit (WoRPD) as a measure for exercise-induced muscle fatigue before and after prolonged calf muscle unloading and in relation to arterial blood flow and muscle perfusion. Eleven male subjects (31 ± 6 years) wore the HEPHAISTOS unloading orthosis unilaterally for 56 days. It allows habitual ambulation while greatly reducing plantar flexor activity and torque production. Endpoint measurements encompassed arterial blood flow, measured in the femoral artery using Doppler ultrasound, oxygenation of the soleus muscle assessed by near-infrared spectroscopy, lactate concentrations determined in capillary blood and muscle activity using soleus muscle surface electromyography. Furthermore, soleus muscle biopsies were taken to investigate morphological muscle changes. After the intervention, maximal isokinetic torque was reduced by 23·4 ± 8·2% (Pflow, tissue oxygenation, lactate concentrations and EMG median frequency kinematics during the exercise test were comparable before and after the intervention, whereas the increase of RMS in response to IIET was less following the intervention (P = 0·03). In conclusion, following submaximal isokinetic muscle work exercise-induced muscle fatigue is unaffected after prolonged local muscle unloading. The observation that arterial blood flow was maintained may underlie the unchanged fatigability. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  9. Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

    Directory of Open Access Journals (Sweden)

    Pedram Niknafs

    2015-05-01

    Full Text Available Neonates with respiratory distress syndrome (RDS, who are treated according to INSURE protocol; require arterial blood gas (ABG analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS, 7.2% were found to have one or more of the followings: acidosis, hypercapnia, or hypoxemia. We found that pulse oximetry in the detection of hyperoxemia had a good validity to appropriately manage patients without blood gas analysis. However, the validity of pulse oximetry was not good enough to detect acidosis, hypercapnia, and hypoxemia.

  10. The subtyping of primary aldosteronism by adrenal vein sampling: sequential blood sampling causes factitious lateralization.

    Science.gov (United States)

    Rossitto, Giacomo; Battistel, Michele; Barbiero, Giulio; Bisogni, Valeria; Maiolino, Giuseppe; Diego, Miotto; Seccia, Teresa M; Rossi, Gian Paolo

    2018-02-01

    The pulsatile secretion of adrenocortical hormones and a stress reaction occurring when starting adrenal vein sampling (AVS) can affect the selectivity and also the assessment of lateralization when sequential blood sampling is used. We therefore tested the hypothesis that a simulated sequential blood sampling could decrease the diagnostic accuracy of lateralization index for identification of aldosterone-producing adenoma (APA), as compared with bilaterally simultaneous AVS. In 138 consecutive patients who underwent subtyping of primary aldosteronism, we compared the results obtained simultaneously bilaterally when starting AVS (t-15) and 15 min after (t0), with those gained with a simulated sequential right-to-left AVS technique (R ⇒ L) created by combining hormonal values obtained at t-15 and at t0. The concordance between simultaneously obtained values at t-15 and t0, and between simultaneously obtained values and values gained with a sequential R ⇒ L technique, was also assessed. We found a marked interindividual variability of lateralization index values in the patients with bilaterally selective AVS at both time point. However, overall the lateralization index simultaneously determined at t0 provided a more accurate identification of APA than the simulated sequential lateralization indexR ⇒ L (P = 0.001). Moreover, regardless of which side was sampled first, the sequential AVS technique induced a sequence-dependent overestimation of lateralization index. While in APA patients the concordance between simultaneous AVS at t0 and t-15 and between simultaneous t0 and sequential technique was moderate-to-good (K = 0.55 and 0.66, respectively), in non-APA patients, it was poor (K = 0.12 and 0.13, respectively). Sequential AVS generates factitious between-sides gradients, which lower its diagnostic accuracy, likely because of the stress reaction arising upon starting AVS.

  11. Technical Note: Measurement of common carotid artery lumen dynamics using black-blood MR cine imaging.

    Science.gov (United States)

    Dai, Erpeng; Dong, Li; Zhang, Zhe; Li, Lyu; Zhang, Hui; Zhao, Xihai; Wang, Jinnan; Yuan, Chun; Guo, Hua

    2017-03-01

    To demonstrate the feasibility of measuring the common carotid artery (CCA) lumen dynamics using a black-blood cine (BB-cine) imaging method. Motion-sensitized driven-equilibrium (MSDE) prepared spoiled gradient sequence was used for the BB-cine imaging. CCAs of eleven healthy volunteers were studied using this method. Lumen dynamics, including lumen area evolution waveforms and distension values, were measured and evaluated by comparing this method with bright-blood cine (BrB-cine) imaging. Compared with the BrB-cine images, flow artifacts were effectively suppressed in the BB-cine images. BrB-cine images generally show larger lumen areas than BB-cine images. The lumen area waveforms and distension measurements from BB-cine imaging showed smaller variances among different subjects than BrB-cine imaging. The proposed BB-cine imaging technique can suppress the flow artifacts effectively and reduce the partial volume effects from the vessel wall. This might allow more accurate lumen dynamics measurements than traditional BrB-cine imaging, which may further be valuable for investigating biomechanical and functional properties of the cardiovascular system. © 2017 American Association of Physicists in Medicine.

  12. Enhancement of automated blood flow estimates (ENABLE) from arterial spin-labeled MRI.

    Science.gov (United States)

    Shirzadi, Zahra; Stefanovic, Bojana; Chappell, Michael A; Ramirez, Joel; Schwindt, Graeme; Masellis, Mario; Black, Sandra E; MacIntosh, Bradley J

    2018-03-01

    To validate a multiparametric automated algorithm-ENhancement of Automated Blood fLow Estimates (ENABLE)-that identifies useful and poor arterial spin-labeled (ASL) difference images in multiple postlabeling delay (PLD) acquisitions and thereby improve clinical ASL. ENABLE is a sort/check algorithm that uses a linear combination of ASL quality features. ENABLE uses simulations to determine quality weighting factors based on an unconstrained nonlinear optimization. We acquired a set of 6-PLD ASL images with 1.5T or 3.0T systems among 98 healthy elderly and adults with mild cognitive impairment or dementia. We contrasted signal-to-noise ratio (SNR) of cerebral blood flow (CBF) images obtained with ENABLE vs. conventional ASL analysis. In a subgroup, we validated our CBF estimates with single-photon emission computed tomography (SPECT) CBF images. ENABLE produced significantly increased SNR compared to a conventional ASL analysis (Wilcoxon signed-rank test, P Wilcoxon signed-rank test, P < 0.0001) and this similarity was strongly related to ASL SNR (t = 24, P < 0.0001). These findings suggest that ENABLE improves CBF image quality from multiple PLD ASL in dementia cohorts at either 1.5T or 3.0T, achieved by multiparametric quality features that guided postprocessing of dementia ASL. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:647-655. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Random perturbations of arterial blood pressure for the assessment of dynamic cerebral autoregulation

    International Nuclear Information System (INIS)

    Katsogridakis, Emmanuel; Panerai, Ronney B; Bush, Glen; Fan, Lingke; Birch, Anthony A; Simpson, David M; Allen, Robert; Potter, John F

    2012-01-01

    The assessment of cerebral autoregulation (CA) relies mostly on methods that modulate arterial blood pressure (ABP). Despite advances, the gold standard of assessment remains elusive and clinical practicality is limited. We investigate a novel approach of assessing CA, consisting of the intermittent application of thigh cuffs using square wave sequences. Our aim was to increase ABP variability whilst minimizing volunteer discomfort, thus improving assessment acceptability. Two random square wave sequences and two maximum pressure settings (80 and 150 mmHg) were used, corresponding to four manoeuvres that were conducted in random order after a baseline recording. The intermittent application of thigh cuffs resulted in an amplitude dependent increase in ABP (p = 0.001) and cerebral blood flow velocity (CBFV) variability (p = 0.026) compared to baseline. No statistically significant differences in mean heart rate or heart rate variability were observed (p = 0.108 and p = 0.350, respectively), suggesting that no significant sympathetic response was elicited. No significant differences in the CBFV step response were observed, suggesting no distortion of autoregulatory parameters resulted from the use of thigh cuffs. We conclude that pseudorandom binary sequences are an effective and safe alternative for increasing ABP variability. This new approach shows great promise as a tool for the robust assessment of CA. (paper)

  14. The Relationship Between the Gensini Score and Complete Blood Count Parameters in Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Muhammet Raşit Sayın

    2012-08-01

    Full Text Available Introduction: The aim of this study was to evaluate the relationship between the extend andseverity of coronary artery disease (CAD determined by the Gensini score and complete bloodcount parameters (white blood cell, hemoglobin, platelet, mean platelet volume, lymphocyte,neutrophil.Patients and Methods: Ninety patients with CAD underwent coronary angiography (40 females,mean age 61 ± 1.2 years were included in this study. Patients with acute coronary syndrome andprior cardiovascular disease excluded from the study. The association between the extent andseverity of CAD, which were assessed by the Gensini score, and complete blood count parameterswas analyzed by a correlation analysis.Results: Coronary angiography revealed, 6 (6.7% patients had three, 16 (17.8% patients hadtwo, and 24 (26.7% patients had single-vessel disease; 44 (48.9% patients had non-criticalstenosis. The mean Gensini score was 19.1 ± 2.1. We found a relationship between white bloodcell and neutrophil counts and the Gensini score. There was no relationship between Gensiniscore and the mean platelet volume and other parameters.Conclusion: The present study supports the hypothesis that inflammation is one of the maincomponent in the pathogenesis of CAD.

  15. The arterial blood supply of the temporomandibular joint: an anatomical study and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Cuccia, Antonino Marco; Caradonna, Carola; Caradonna, Domenico [Dept. of Surgical and Oncological Disciplines, University of Palermo, Palermo (Italy); Anastasi, Giuseppe; Milardi, Demetrio; Favaloro, Angelo; Caradonna, Luigi; Cutroneo, Giuseppina [Biomorphology and Biotechnologies, University of Messina, Messina (Italy); De Pietro, Anita; Angileri, Tommaso Maurizio [Villa Santa Teresa, Diagnostica per Immagini, Palermo (Italy)

    2013-03-15

    The aim of this study was to analyze three-dimensional images of the arterial supply to the temporomandibular joint. Ten patients (five men and five women, mean age 36 years) without signs or symptoms of temporomandibular disorders, who underwent contrast-enhanced computed tomographic (CT) scanning with intravenous contrast, were studied. The direct volume rendering technique of CT images was used, and a data set of images to visualize the vasculature of the human temporomandibular joint in three dimensions was created. After elaboration of the data through post-processing, the arterial supply of the temporomandibular joint was studied. The analysis revealed the superficial temporal artery, the anterior tympanic artery, the deep temporal artery, the auricular posterior artery, the transverse facial artery, the middle meningeal artery, and the maxillary artery with their branches as the main arterial sources for the lateral and medial temporomandibular joint. The direct volume rendering technique was found to be successful in the assessment of the arterial supply to the temporomandibular joint. The superficial temporal artery and maxillary artery ran along the lateral and medial sides of the condylar neck, suggesting that these arteries are at increased risk during soft-tissue procedures such as an elective arthroplasty of the temporomandibular joint.

  16. A pressão arterial está sendo medida? Is the blood pressure being measured?

    Directory of Open Access Journals (Sweden)

    Débora C. Alavarce

    2000-03-01

    Full Text Available A medida da pressão arterial faz parte do exame físico e deve ser realizada em toda consulta médica. Para avaliar se a pressão arterial é medida nas consultas médicas, foram consultados 500 prontuários de pacientes de primeira consulta ambulatorial, sendo 335 (67% provenientes de clínicas médicas e cirúrgicas e 165 (33% das clínicas ginecológica e obstétrica. A pressão arterial foi anotada em 39% das consultas realizadas (135±32/85±19 mm Hg, sendo que em 11% destas anotações a pressão diastólica estava acima de 90 mm Hg. Em relação ao diagnóstico prévio de hipertensão arterial verificou-se que: a em 62% dos prontuários não havia esta informação; b 20% referiram ter hipertensão, e em 79% destes a pressão arterial foi anotada; e c 18% referiram não ter hipertensão e 46% destes tiveram registro da pressão arterial. Portanto, a maior parte dos pacientes não teve sua pressão arterial anotada.The blood pressure measure is part of the physical exam and it should be accomplished in every medical consultation. To verify the blood pressure measured in the accomplished medical consultations record of first they were consulted it consults 500 patient's ambulatorial being 335 (67% coming of medical and surgical clinics and 165 (33% of the gynecological and obstetric clinics. The blood pressure was written down in 39% of the accomplished consultations (135+32 mm Hg 85+19 mm Hg, and 11% of this annotations the pressure diastólica was above 90 mm Hg. In relation to the previous diagnosis of hypertension it was verified that: a in 62% of the records there was not this information; b 20% referred to have hypertension, and in 79% of these the arterial pressure was scored; and c 18% referred not to have hypertension and 46% of these had registration of the arterial pressure. Therefore, most of the patients didn't have its logged arterial pressure.

  17. Performance of an app measuring spot quality in dried blood spot sampling

    NARCIS (Netherlands)

    Veenhof, Herman

    2016-01-01

    Introduction: The Dried Blood Spot sampling (DBS) method gives patients and health care workers the opportunity for remote sampling using a drop of blood from a fingerprick on a sampling card which can be send to the laboratory by mail. Laboratory analysts frequently reject DBS samples because of

  18. Continuous Blood Glucose Monitoring May Detect Carotid Occlusion Intolerance during Carotid Artery Stenting.

    Science.gov (United States)

    Hiramatsu, Ryo; Furuse, Motomasa; Yagi, Ryokichi; Ohmura, Tomohisa; Ohnishi, Hiroyuki; Ikeda, Naokado; Nonoguchi, Naosuke; Kawabata, Shinji; Miyachi, Shigeru; Kuroiwa, Toshihiko

    2018-02-05

    The frequency of the occurrence of adverse events associated with carotid artery stenting (CAS) is usually low, but serious adverse events such as cerebral hyperperfusion syndrome (CHS) may occur. Real-time monitoring is ideal for the early detection of adverse events during the surgical procedure. This study aimed to evaluate continuous blood glucose (BG) monitoring for the detection of adverse events during CAS. Forty patients undergoing scheduled CAS were prospectively enrolled. An artificial pancreas was used for continuous BG monitoring (once per minute), using venous blood extracted at a rate of 2 mL/hr during CAS. The primary endpoint was a correlation between BG change and adverse events. CAS was discontinued in 1 patient, and BG was not measured in 5 patients (12.5%) because of the inability to extract blood. Among 34 evaluable patients, no patient developed CHS, but 3 patients (9%) experienced carotid occlusion intolerance. During CAS, BG was significantly higher in patients with carotid occlusion intolerance (median: 5 mg/dL) than in patients without carotid occlusion intolerance (median: 0 mg/dL) (P = 0.0221). A cutoff BG value ≥4 mg/dL during CAS showed 50% sensitivity and 100% specificity for the detection of carotid occlusion intolerance. There was no significant correlation between BG change and other adverse events. BG elevation may help detect carotid occlusion intolerance although it is still unknown whether BG monitoring can detect CHS. Further studies should validate that a cutoff BG elevation value of ≥4 mg/dL during CAS indicates carotid occlusion intolerance. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Alterations of Blood Flow Through Arteries Following Atherectomy and the Impact on Pressure Variation and Velocity.

    Science.gov (United States)

    Plourde, Brian D; Vallez, Lauren J; Sun, Biyuan; Nelson-Cheeseman, Brittany B; Abraham, John P; Staniloae, Cezar S

    2016-09-01

    Simulations were made of the pressure and velocity fields throughout an artery before and after removal of plaque using orbital atherectomy plus adjunctive balloon angioplasty or stenting. The calculations were carried out with an unsteady computational fluid dynamic solver that allows the fluid to naturally transition to turbulence. The results of the atherectomy procedure leads to an increased flow through the stenotic zone with a coincident decrease in pressure drop across the stenosis. The measured effect of atherectomy and adjunctive treatment showed decrease the systolic pressure drop by a factor of 2.3. Waveforms obtained from a measurements were input into a numerical simulation of blood flow through geometry obtained from medical imaging. From the numerical simulations, a detailed investigation of the sources of pressure loss was obtained. It is found that the major sources of pressure drop are related to the acceleration of blood through heavily occluded cross sections and the imperfect flow recovery downstream. This finding suggests that targeting only the most occluded parts of a stenosis would benefit the hemodynamics. The calculated change in systolic pressure drop through the lesion was a factor of 2.4, in excellent agreement with the measured improvement. The systolic and cardiac-cycle-average pressure results were compared with measurements made in a multi-patient study treated with orbital atherectomy and adjunctive treatment. The agreements between the measured and calculated systolic pressure drop before and after the treatment were within 3%. This excellent agreement adds further confidence to the results. This research demonstrates the use of orbital atherectomy to facilitate balloon expansion to restore blood flow and how pressure measurements can be utilized to optimize revascularization of occluded peripheral vessels.

  20. Restrictive versus liberal blood transfusion in patients with coronary artery disease: a meta-analysis.

    Science.gov (United States)

    Wang, Yushu; Shi, Xiuli; Wen, Meiqin; Chen, Yucheng; Zhang, Qing

    2017-04-01

    To compare clinical outcomes between restrictive versus liberal blood transfusion strategies in patients with coronary artery disease (CAD). A literature search from January 1966 to May 2016 was performed in PubMed, EMBASE and Cochrane Library to find trials evaluating a restrictive hemoglobin transfusion trigger of ≤8 g/dL, compared with a more liberal trigger. Two study authors independently extracted data from the trials. The primary outcome was mortality and the secondary outcome was subsequent myocardial infarction. Relative risks (RRs) with their 95% confidence intervals (CIs) were assessed. Six trials involving 133,058 participants were included in this study. Pooled results revealed no difference in mortality between the liberal transfusion and restrictive transfusions (RR = 1.17, 95% CI = 0.91-1.52, P = .22). Subgroup analysis revealed that a restrictive transfusion strategy was associated with a higher risk of in-hospital mortality (RR = 1.38, 95% CI = 1.15-1.67, P transfusion strategy and restrictive transfusion strategy in risk for subsequent myocardial infarction (RR = 1.09, 95% CI = 0.57-2.06, P = .80). Limitations include (1) limited number of trials, especially those evaluating myocardial infarction, (2) observed heterogeneity, (3) confounding by indication and other inherent bias may exist. The findings suggest that restrictive blood transfusion was associated with higher in-hospital and 30 day mortality than liberal blood transfusion in CAD patients. The conclusions are mainly based on retrospective studies and should not be considered as recommendation before they are supported by randomized controlled trials.

  1. Virtual arterial blood pressure feedback improves chest compression quality during simulated resuscitation.

    Science.gov (United States)

    Rieke, Horst; Rieke, Martin; Gado, Samkon K; Nietert, Paul J; Field, Larry C; Clark, Carlee A; Furse, Cory M; McEvoy, Matthew D

    2013-11-01

    Quality chest compressions (CC) are the most important factor in successful cardiopulmonary resuscitation. Adjustment of CC based upon an invasive arterial blood pressure (ABP) display would be theoretically beneficial. Additionally, having one compressor present for longer than a 2-min cycle with an ABP display may allow for a learning process to further maximize CC. Accordingly, we tested the hypothesis that CC can be improved with a real-time display of invasively measured blood pressure and with an unchanged, physically fit compressor. A manikin was attached to an ABP display derived from a hemodynamic model responding to parameters of CC rate, depth, and compression-decompression ratio. The area under the blood pressure curve over time (AUC) was used for data analysis. Each participant (N=20) performed 4 CPR sessions: (1) No ABP display, exchange of compressor every 2 min; (2) ABP display, exchange of compressor every 2 min; (3) no ABP display, no exchange of the compressor; (4) ABP display, no exchange of the compressor. Data were analyzed by ANOVA. Significance was set at a p-valueAUC for cycles without ABP display was 5201 mm Hgs (95% confidence interval (CI) of 4804-5597 mm Hgs), and for cycles with ABP display 6110 mm Hgs (95% CI of 5715-6507 mm Hgs) (pAUC increase with ABP display for each participant was 20.2±17.4% 95 CI (p<0.0001). Our study confirms the hypothesis that a real-time display of simulated ABP during CPR that responds to participant performance improves achieved and sustained ABP. However, without any real-time visual feedback, even fit compressors demonstrated degradation of CC quality. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Insulin resistance is associated with lower arterial blood flow and reduced cortical perfusion in cognitively asymptomatic middle-aged adults

    Science.gov (United States)

    Hoscheidt, Siobhan M; Kellawan, J Mikhail; Berman, Sara E; Rivera-Rivera, Leonardo A; Krause, Rachel A; Oh, Jennifer M; Beeri, Michal S; Rowley, Howard A; Wieben, Oliver; Carlsson, Cynthia M; Asthana, Sanjay; Johnson, Sterling C; Schrage, William G

    2016-01-01

    Insulin resistance (IR) is associated with poor cerebrovascular health and increased risk for dementia. Little is known about the unique effect of IR on both micro- and macrovascular flow particularly in midlife when interventions against dementia may be most effective. We examined the effect of IR as indexed by the Homeostatic Model Assessment of Insulin Resistance (HOMA-IR) on cerebral blood flow in macro- and microvessels utilizing magnetic resonance imaging (MRI) among cognitively asymptomatic middle-aged individuals. We hypothesized that higher HOMA-IR would be associated with reduced flow in macrovessels and lower cortical perfusion. One hundred and twenty cognitively asymptomatic middle-aged adults (57 ± 5 yrs) underwent fasting blood draw, phase contrast-vastly undersampled isotropic projection reconstruction (PC VIPR) MRI, and arterial spin labeling (ASL) perfusion. Higher HOMA-IR was associated with lower arterial blood flow, particularly within the internal carotid arteries (ICAs), and lower cerebral perfusion in several brain regions including frontal and temporal lobe regions. Higher blood flow in bilateral ICAs predicted greater cortical perfusion in individuals with lower HOMA-IR, a relationship not observed among those with higher HOMA-IR. Findings provide novel evidence for an uncoupling of macrovascular blood flow and microvascular perfusion among individuals with higher IR in midlife. PMID:27488909

  3. Arterial blood supply to the caudate lobe of the liver from the proximal branches of the right inferior phrenic artery in patients with recurrent hepatocellular carcinoma after chemoembolization

    International Nuclear Information System (INIS)

    Miyayama, Shiro; Yamashiro, Masashi; Shibata, Yoshihiro; Hashimoto, Masahiro; Yoshida, Miki; Tsuji, Kazunobu; Toshima, Fumihito; Matsui, Osamu

    2012-01-01

    The purpose of this study was to evaluate the arterial blood supply to the caudate lobe of the liver from the proximal branches of the right inferior phrenic artery (RIPA) in patients with recurrent hepatocellular carcinoma after transcatheter arterial chemoembolization (TACE). Thirteen patients, including 10 who had a history of TACE of the caudate artery (A1), underwent TACE of the proximal RIPA branches. Iodized oil distribution was evaluated by computed tomography (CT) 1-week after TACE. Angiographic findings were also evaluated. Previously embolized A1 was occluded (n=15) or attenuated (n=2). In one of three patients without A1 TACE, A1 was also attenuated. TACE was performed at the first branch of the proximal RIPA (n=8), the first branch of the anterior branch (n=6), and the first branch of the posterior branch (n=1), respectively. Iodized oil was mainly distributed into the dorsal part of the Siegel lobe (SP) (n=10), the caudate process (n=1), and both (n=2). In three of seven patients who had undergone serial RIPA angiography, RIPA parasitization to SP was suspected before A1 TACE. The proximal RIPA branches mainly supply the SP when A1 is attenuated. (author)

  4. Ambulatory (24 h) blood pressure and arterial stiffness measurement in Marfan syndrome patients: a case control feasibility and pilot study.

    Science.gov (United States)

    Hillebrand, Matthias; Nouri, Ghazaleh; Hametner, Bernhard; Parragh, Stephanie; Köster, Jelena; Mortensen, Kai; Schwarz, Achim; von Kodolitsch, Yskert; Wassertheurer, Siegfried

    2016-05-06

    The aim of this work is the investigation of measures of ambulatory brachial and aortic blood pressure and indices of arterial stiffness and aortic wave reflection in Marfan patients. A case-control study was conducted including patients with diagnosed Marfan syndrome following Ghent2 nosology and healthy controls matched for sex, age and daytime brachial systolic blood pressure. For each subject a 24 h ambulatory blood pressure and 24 h pulse wave analysis measurement was performed. All parameters showed a circadian pattern whereby pressure dipping was more pronounced in Marfan patients. During daytime only Marfan patients with aortic root surgery showed increased pulse wave velocity. In contrast, various nighttime measurements, wave reflection determinants and circadian patterns showed a significant difference. The findings of our study provide evidence that ambulatory measurement of arterial stiffness parameters is feasible and that these determinants are significantly different in Marfan syndrome patients compared to controls in particular at nighttime. Further investigation is therefore indicated.

  5. On the mechanisms of blunted nocturnal decline in arterial blood pressure in NIDDM patients with diabetic nephropathy

    DEFF Research Database (Denmark)

    Nielsen, Flemming Steen; Rossing, P; Bang, L E

    1995-01-01

    Nondiabetic hypertensive patients lacking the normal nocturnal decline in arterial blood pressure have enhanced cardiovascular complications. Since cardiovascular morbidity and mortality are increased in non-insulin-dependent diabetes mellitus (NIDDM), we performed a prospective cross......-sectional case-controlled study comparing the diurnal variation in arterial blood pressure, prevalence of dippers, cardiac autonomic nervous function (beat-to-beat variation during deep breathing), and extracellular fluid volume (51Cr-labeled EDTA) in 55 NIDDM patients with diabetic nephropathy (group 1), 55...... NIDDM patients with normoalbuminuria (group 2), and 22 nondiabetic control subjects (group 3). All antihypertensive treatments were withdrawn at least 2 weeks before the study. The nocturnal blood pressure reduction (daytime-to-nighttime)/daytime (mean +/- SE) was impaired in group 1 (6.6 +/- 1...

  6. High incidence of the median artery of the forearm in a sample of recent southern African cadavers.

    Science.gov (United States)

    Henneberg, M; George, B J

    1992-01-01

    Observations of the presence of the median artery, providing substantial blood supply to the hand, were conducted on 96 dissected forearms of 15 adult African females and 49 adult males. The artery has a much higher incidence (27.1%) than previously reported by any author. There is no significant difference in its occurrence between sexes, nor between right and left limbs. The artery seems to occur more often bilaterally than unilaterally. The presence of the artery is not related to age. From a theoretical standpoint it is difficult to accept that a structure present in more than 1 in 4 of individuals should be considered an 'anomaly' or a 'variant'. A different approach to description of normal human anatomy is therefore necessary--that of presenting alternative anatomical patterns of equal standing rather than a single 'normal' pattern. Images Fig. 1 Fig. 2 Fig. 3 PMID:1452474

  7. Assessment of resting-state blood flow through anterior cerebral arteries using trans-cranial doppler recordings.

    Science.gov (United States)

    Huang, Hanrui; Sejdić, Ervin

    2013-12-01

    Trans-cranial Doppler (TCD) recordings are used to monitor cerebral blood flow in the main cerebral arteries. The resting state is usually characterized by the mean velocity or the maximum Doppler shift frequency (an envelope signal) by insonating the middle cerebral arteries. In this study, we characterized cerebral blood flow in the anterior cerebral arteries. We analyzed both envelope signals and raw signals obtained from bilateral insonation. We recruited 20 healthy patients and conducted the data acquisition for 15 min. Features were extracted from the time domain, the frequency domain and the time-frequency domain. The results indicate that a gender-based statistical difference exists in the frequency and time-frequency domains. However, no handedness effect was found. In the time domain, information-theoretic features indicated that mutual dependence is higher in raw signals than in envelope signals. Finally, we concluded that insonation of the anterior cerebral arteries serves as a complement to middle cerebral artery studies. Additionally, investigation of the raw signals provided us with additional information that is not otherwise available from envelope signals. Use of direct trans-cranial Doppler raw data is therefore validated as a valuable method for characterizing the resting state. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Effect of different dosages of nitroglycerin infusion on arterial blood gas tensions in patients undergoing on- pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Masoumi, Gholamreza; Pour, Evaz Hidar; Sadeghpour, Ali; Ziayeefard, Mohsen; Alavi, Mostapha; Anbardan, Sanam Javid; Shirani, Shahin

    2012-02-01

    On-pump coronary artery bypass graft (CABG) surgery impairs gas exchange in the early postoperative period. The main object on this study was evaluation of changes in arterial blood gas values in patients underwent on pump CABG surgery receiving different dose of intravenous nitroglycerin (NTG). sixty-seven consecutive patients undergoing elective on-pump CABG randomly enrolled into three groups receiving NTG 50 μg/min (Group N1, n =67), 100 μg/min (Group N2, n = 67), and 150 μg/min (Group N3, n = 67). Arterial blood gas (ABG) tensions were evaluated just before induction of anesthesia, during anesthesia, at the end of warming up period, and 6 h after admission to the intensive care unit. Pao2 and PH had the highest value during surgery in Group N1, Group N2, and Group N3. No significant difference was noted in mean values of Pao2 and PH during surgery between three groups (P > 0.05). There was no significant difference in HCO3 values in different time intervals among three groups (P > 0.05). our results showed that infusing three different dosage of NTG (50, 100, and 150 μg/min) had no significant effect on ABG tensions in patients underwent on-pump CABG surgery.

  9. On the shape of the common carotid artery with implications for blood velocity profiles

    International Nuclear Information System (INIS)

    Manbachi, Amir; Hoi, Yiemeng; Steinman, David A; Wasserman, Bruce A; Lakatta, Edward G

    2011-01-01

    Clinical and engineering studies typically assume that the common carotid artery (CCA) is straight enough to assume fully developed flow, yet recent studies have demonstrated the presence of skewed velocity profiles. Toward elucidating the influence of mild vascular curvatures on blood flow patterns and atherosclerosis, this study aimed to characterize the three-dimensional shape of the human CCA. The left and right carotid arteries of 28 participants (63 ± 12 years) in the VALIDATE (Vascular Aging-–The Link that Bridges Age to Atherosclerosis) study were digitally segmented from 3D contrast-enhanced magnetic resonance angiograms, from the aortic arch to the carotid bifurcation. Each CCA was divided into nominal cervical and thoracic segments, for which curvatures were estimated by least-squares fitting of the respective centerlines to planar arcs. The cervical CCA had a mean radius of curvature of 127 mm, corresponding to a mean lumen:curvature radius ratio of 1:50. The thoracic CCA was significantly more curved at 1:16, with the plane of curvature tilted by a mean angle of 25° and rotated close to 90° with respect to that of the cervical CCA. The left CCA was significantly longer and slightly more curved than the right CCA, and there was a weak but significant increase in CCA curvature with age. Computational fluid dynamic simulations carried out for idealized CCA geometries derived from these and other measured geometric parameters demonstrated that mild cervical curvature is sufficient to prevent flow from fully-developing to axisymmetry, independent of the degree of thoracic curvature. These findings reinforce the idea that fully developed flow may be the exception rather than the rule for the CCA, and perhaps other nominally long and straight vessels

  10. Asymptotic analysis of blood flow in stented arteries: time dependency and direct simulations***

    Directory of Open Access Journals (Sweden)

    Pichon Gostaf Kirill

    2010-12-01

    Full Text Available This work aims to extend in two distinct directions results recently obtained in [10]. In a first step we focus on the possible extension of our results to the time dependent case. Whereas in the second part some preliminary numerical simulations aim to give orders of magnitudes in terms of numerical costs of direct 3D simulations. We consider, in the first part, the time dependent rough problem for a simplified heat equation in a straight channel that mimics the axial velocity under an oscillating pressure gradient. We derive first order approximations with respect to ϵ, the size of the roughness. In order to understand the problem and set up correct boundary layer approximations, we perform a time periodic fourier analysis and check that no frequency can interact with the roughness. We show rigorously on this toy problem that the boundary layers remain stationary in time (independent on the frequency number. Finally we perform numerical tests validating our theoretical approach. In the second part, we determine actual limits, when running three-dimensional blood flow simulations of the non-homogenized stented arteries. We solve the stationary Stokes equations for an artery containing a saccular aneurysm. Consecutive levels of uniform mesh refinement, serve to relate spatial resolution, problem scale, and required computation time. Test computations are presented for femoral side aneurysm, where a simplified ten-wire stent model was placed across the aneurysm throat. We advocate the proposed stent homogenization model, by concluding that an actual computation power is not sufficient to run accurate, direct simulations of a pulsatile flow in stented vessels.

  11. Blood Pressure Control in Smokers with Arterial Hypertension Who Switched to Electronic Cigarettes

    Directory of Open Access Journals (Sweden)

    Riccardo Polosa

    2016-11-01

    Full Text Available Electronic cigarettes (ECs are battery-operated devices designed to vaporise nicotine, which may help smokers with quitting or reducing their tobacco consumption. No data is available regarding the health effects of ECs use among smokers with arterial hypertension and whether regular use results in blood pressure (BP changes. We investigated long-term changes in resting BP and level of BP control in hypertensive smokers who quit or reduced substantially their tobacco consumption by switching to ECs. A medical records review of patients with hypertension was conducted to identify patients reporting regular daily use of ECs on at least two consecutive follow-up visits. Regularly smoking hypertensive patients were included as a reference group. A marked reduction in cigarette consumption was observed in ECs users (n = 43 though consumption remained unchanged in the control group (n = 46. Compared to baseline, at 12 months (follow-up visit 2 decline in cigarette consumption was associated with significant reductions in median (25th-, 75th-centile systolic BP (140 (134.5, 144 to 130 (123.5, 138.5 mmHg; p < 0.001 and diastolic BP (86 (78, 90 to 80 (74.5, 90 mmHg; p = 0.006. No significant changes were observed in the control group. As expected, decline in cigarette consumption in the ECs users was also associated with improved BP control. The study concludes that regular ECs use may aid smokers with arterial hypertension reduce or abstain from cigarette smoking, with only trivial post-cessation weight gain. This resulted in improvements in systolic and diastolic BP as well as better BP control.

  12. Measuring systolic arterial blood pressure. Possible errors from extension tubes or disposable transducer domes.

    Science.gov (United States)

    Rothe, C F; Kim, K C

    1980-11-01

    The purpose of this study was to evaluate the magnitude of possible error in the measurement of systolic blood pressure if disposable, built-in diaphragm, transducer domes or long extension tubes between the patient and pressure transducer are used. Sinusoidal or arterial pressure patterns were generated with specially designed equipment. With a long extension tube or trapped air bubbles, the resonant frequency of the catheter system was reduced so that the arterial pulse was amplified as it acted on the transducer and, thus, gave an erroneously high systolic pressure measurement. The authors found this error to be as much as 20 mm Hg. Trapped air bubbles, not stopcocks or connections, per se, lead to poor fidelity. The utility of a continuous catheter flush system (Sorenson, Intraflow) to estimate the resonant frequency and degree of damping of a catheter-transducer system is described, as are possibly erroneous conclusions. Given a rough estimate of the resonant frequency of a catheter-transducer system and the magnitude of overshoot in response to a pulse, the authors present a table to predict the magnitude of probable error. These studies confirm the variability and unreliability of static calibration that may occur using some safety diaphragm domes and show that the system frequency response is decreased if air bubbles are trapped between the diaphragms. The authors conclude that regular procedures should be established to evaluate the accuracy of the pressure measuring systems in use, the transducer should be placed as close to the patient as possible, the air bubbles should be assiduously eliminated from the system.

  13. Opposing effects of particle pollution, ozone, and ambient temperature on arterial blood pressure.

    Science.gov (United States)

    Hoffmann, Barbara; Luttmann-Gibson, Heike; Cohen, Allison; Zanobetti, Antonella; de Souza, Celine; Foley, Christopher; Suh, Helen H; Coull, Brent A; Schwartz, Joel; Mittleman, Murray; Stone, Peter; Horton, Edward; Gold, Diane R

    2012-02-01

    Diabetes increases the risk of hypertension and orthostatic hypotension and raises the risk of cardiovascular death during heat waves and high pollution episodes. We examined whether short-term exposures to air pollution (fine particles, ozone) and heat resulted in perturbation of arterial blood pressure (BP) in persons with type 2 diabetes mellitus (T2DM). We conducted a panel study in 70 subjects with T2DM, measuring BP by automated oscillometric sphygmomanometer and pulse wave analysis every 2 weeks on up to five occasions (355 repeated measures). Hourly central site measurements of fine particles, ozone, and meteorology were conducted. We applied linear mixed models with random participant intercepts to investigate the association of fine particles, ozone, and ambient temperature with systolic, diastolic, and mean arterial BP in a multipollutant model, controlling for season, meteorological variables, and subject characteristics. An interquartile increase in ambient fine particle mass [particulate matter (PM) with an aerodynamic diameter of ≤ 2.5 μm (PM2.5)] and in the traffic component black carbon in the previous 5 days (3.54 and 0.25 μg/m3, respectively) predicted increases of 1.4 mmHg [95% confidence interval (CI): 0.0, 2.9 mmHg] and 2.2 mmHg (95% CI: 0.4, 4.0 mmHg) in systolic BP (SBP) at the population geometric mean, respectively. In contrast, an interquartile increase in the 5-day mean of ozone (13.3 ppb) was associated with a 5.2 mmHg (95% CI: -8.6, -1.8 mmHg) decrease in SBP. Higher temperatures were associated with a marginal decrease in BP. In subjects with T2DM, PM was associated with increased BP, and ozone was associated with decreased BP. These effects may be clinically important in patients with already compromised autoregulatory function.

  14. Effects of Weather and Heliophysical Conditions on Emergency Ambulance Calls for Elevated Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Jone Vencloviene

    2015-02-01

    Full Text Available We hypothesized that weather and space weather conditions were associated with the exacerbation of essential hypertension. The study was conducted during 2009–2010 in the city of Kaunas, Lithuania. We analyzed 13,475 cards from emergency ambulance calls (EACs, in which the conditions for the emergency calls were made coded I.10–I.15. The Kaunas Weather Station provided daily records of air temperature (T, wind speed (WS, relative humidity, and barometric pressure (BP. We evaluated the associations between daily weather variables and daily number of EACs by applying a multivariate Poisson regression. Unfavorable heliophysical conditions (two days after the active-stormy geomagnetic field or the days with solar WS > 600 km/s increased the daily number of elevated arterial blood pressure (EABP by 12% (RR = 1.12; 95% confidence interval (CI 1.04–1.21; and WS ≥ 3.5 knots during days of T < 1.5 °C and T ≥ 12.5 °C by 8% (RR = 1.08; CI 1.04–1.12. An increase of T by 10 °C and an elevation of BP two days after by 10 hPa were associated with a decrease in RR by 3%. An additional effect of T was detected during days of T ≥ 17.5 °C only in females. Women and patients with grade III arterial hypertension at the time of the ambulance call were more sensitive to weather conditions. These results may help in the understanding of the population’s sensitivity to different weather conditions.

  15. Middle cerebral artery blood flow velocity during beach chair position for shoulder surgery under general anesthesia.

    Science.gov (United States)

    Hanouz, Jean-Luc; Fiant, Anne-Lise; Gérard, Jean-Louis

    2016-09-01

    The goal of the present study was to examine changes of middle cerebral artery (VMCA) blood flow velocity in patients scheduled for shoulder surgery in beach chair position. Prospective observational study. Operating room, shoulder surgery. Fifty-three consecutive patients scheduled for shoulder surgery in beach chair position. Transcranial Doppler performed after induction of general anesthesia (baseline), after beach chair positioning (BC1), during surgery 20minutes (BC2), and after back to supine position before stopping anesthesia (supine). Mean arterial pressure (MAP), end-tidal CO2, and volatile anesthetic concentration and VMCA were recorded at baseline, BC1, BC2, and supine. Postoperative neurologic complications were searched. Beach chair position induced decrease in MAP (baseline: 73±10mm Hg vs lower MAP recorded: 61±10mm Hg; P<.0001) requiring vasopressors and fluid challenge in 44 patients (83%). There was a significant decrease in VMCA after beach chair positioning (BC1: 33±10cm/s vs baseline: 39±14cm/s; P=.001). The VMCA at baseline (39±2cm/s), BC2 (35±14cm/s), and supine (39±14cm/s) were not different. The minimal alveolar concentration of volatile anesthetics, end-tidal CO2, SpO2, and MAP were not different at baseline, BC1, BC2, and supine. Beach chair position resulted in transient decrease in MAP requiring fluid challenge and vasopressors and a moderate decrease in VMCA. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Cerebral small-resistance artery structure and cerebral blood flow in normotensive subjects and hypertensive patients

    Energy Technology Data Exchange (ETDEWEB)

    De Ciuceis, Carolina; Porteri, Enzo; Rizzoni, Damiano; Boari, Gianluca E.M.; Rosei, Enrico Agabiti [University of Brescia, Clinica Medica, Department of Clinical and Experimental Sciences, Brescia (Italy); Cornali, Claudio; Mardighian, Dikran; Fontanella, Marco M. [University of Brescia, Section of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); Pinardi, Chiara [Spedali Civili, Medical Physics Unit, Brescia (Italy); University of Brescia, Section of Neuroradiology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); Rodella, Luigi F.; Rezzani, Rita [University of Brescia, Section of Anatomy, Department of Clinical and Experimental Sciences, Brescia (Italy); Gasparotti, Roberto [University of Brescia, Section of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); University of Brescia, Section of Neuroradiology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy)

    2014-12-15

    The aim of this study was to prospectively investigate whether the structure of cerebral small-resistance arteries is related to cerebral perfusion parameters as measured with dynamic susceptibility-weighted contrast magnetic resonance imaging (DSC-MRI) in a selected cohort of hypertensive and normotensive patients. Ten hypertensive and 10 normotensive patients were included in the study. All patients underwent neurosurgical intervention for an intracranial tumor and were investigated with DSC-MRI at 1.5 T. Cerebral small-resistance arteries were dissected from a small portion of morphologically normal cerebral tissue and mounted on an isometric myograph for the measurement of the media-to-lumen (M/L) ratio. A quantitative assessment of cerebral blood flow (CBF) and volume (CBV) was performed with a region-of-interest approach. Correlation coefficients were calculated for normally distributed variables. The institutional review board approved the study, and informed consent was obtained from all patients. Compared with normotensive subjects, hypertensive patients had significantly lower regional CBF (mL/100 g/min) in the cortical grey matter (55.63 ± 1.90 vs 58.37 ± 2.19, p < 0.05), basal ganglia (53.34 ± 4.39 vs 58.22. ± 4.33, p < 0.05), thalami (50.65 ± 3.23 vs 57.56 ± 4.45, p < 0.01), subcortical white matter (19.32 ± 2.54 vs 22.24 ± 1.9, p < 0.05), greater M/L ratio (0.099 ± 0.013 vs 0.085 ± 0.012, p < 0.05), and lower microvessel density (1.66 ± 0.67 vs 2.52 ± 1.28, p < 0.05). A statistically significant negative correlation was observed between M/L ratio of cerebral arteries and CBF in the cortical grey matter (r = -0.516, p < 0.05), basal ganglia (r = -0.521, p < 0.05), thalami (r = -0.527 p < 0.05), and subcortical white matter (r = -0.612, p < 0.01). Our results indicate that microvascular structure might play a role in controlling CBF, with possible clinical consequences. (orig.)

  17. A semi-automatic technique for measurement of arterial wall from black blood MRI

    International Nuclear Information System (INIS)

    Ladak, Hanif M.; Thomas, Jonathan B.; Mitchell, J. Ross; Rutt, Brian K.; Steinman, David A.

    2001-01-01

    Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semi-automatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple

  18. Hematocrit, Anemia, and Arm Preference for Blood Sample ...

    African Journals Online (AJOL)

    lower cut-off of 33% or hemoglobin (Hb) concentration of. 11 gram% was ... venous blood of 200 antenatal women at the University of Nigeria Teaching Hospital (UNTH). Enugu ..... and emphasis was placed on the importance of good nutrition.

  19. Blood samples in the neutron beam; Blutproben im Neutronenstrahl

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2012-07-01

    Whether crocodile, platypus, man, or chicken: Always the hemoglobin in the red blood cells has the same task. It carries oxygen from the lungs throughout the body. In investigative manner and international team around Dr. Andreas Stadler from the Julic Research Center has deciphered in detail, how and why the hemoglobines of these creatures nevertheless differ. Their findings are among others interesting for the research on artificial blood.

  20. Differential increases in blood flow velocity in the middle cerebral artery after tourniquet deflation during sevoflurane, isoflurane or propofol anaesthesia.

    Science.gov (United States)

    Kadoi, Y; Kawauchi, C H; Ide, M; Saito, S; Mizutani, A

    2009-07-01

    The purpose of this study was to examine the comparative effects of sevoflurane, isoflurane or propofol on cerebral blood flow velocity after tourniquet deflation during orthopaedic surgery. Thirty patients undergoing elective orthopaedic surgery were randomly divided into sevoflurane, isoflurane and propofol groups. Anaesthesia was maintained with sevoflurane, isoflurane or propofol infusion in 33% oxygen and 67% nitrous oxide, in whatever concentrations were necessary to keep bispectral index values between 45 and 50. Ventilatory rate or tidal volume was adjusted to target PaCO2 of 35 mmHg. A 2.0 MHz transcranial Doppler probe was attached to the patient's head at the temporal window and mean blood flow velocity in the middle cerebral artery was continuously measured. The extremity was exsanguinated with an Esmarch bandage and the pneumatic tourniquet was inflated to a pressure of 450 mmHg. Arterial blood pressure, heart rate, velocity in the middle cerebral artery and arterial blood gas analysis were measured every minute for 10 minutes after release of the tourniquet in all three groups. Velocity in the middle cerebral artery in the three groups increased for five minutes after tourniquet deflation. Because of the different cerebrovascular effects of the three agents, the degree of increase in flow velocity in the isoflurane group was greater than in the other two groups, the change in flow velocity in the propofol group being the lowest (at three minutes after deflation 40 +/- 7%, 32 +/- 6% and 28 +/- 10% in the isoflurane, sevoflurane and propofol groups respectively, P < 0.05).

  1. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    Science.gov (United States)

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (pair space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (ptransport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (ptransport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Algunas consideraciones sobre la hipertensión arterial en la diabetes mellitus tipo 2 Some considerations related to arterial high blood pressure in Type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Yanes Quesada

    2009-09-01

    Full Text Available Se realizó una revisión del tema relacionado con la hipertensión arterial en el paciente diabético tipo 2, con el objetivo de actualizar algunos elementos particulares en este grupo de pacientes. Se plantea que su prevalencia es considerablemente más alta que en la población no diabética, donde la hiperinsulinemia y la disfunción endotelial cobran un papel protagónico en su etiopatogenia. La hipertensión arterial en estos pacientes clínicamente se manifiesta como un patrón non dipper, lo que incrementa la morbimortalidad por esta entidad. El tratamiento medicamentoso es habitualmente necesario, y se usan como drogas de primera línea los inhibidores de la enzima convertidora, los antagonistas de los receptores de angiotensina ll y los calcioantagonistas, aunque se pueden utilizar también los diuréticos tiacídicos a dosis bajas.Authors made a review of the topic related to arterial high blood pressure in the patient presenting with Type 2 diabetes mellitus to update some particular elements in this group of patients. We propose that its prevalence is higher than that present in non-diabetic population, where the hyperinsulinism and the endothelial dysfunction have a leading role in its ethiopathogenesis. The arterial high blood pressure in these patients clinically is manifested as a non-dipper pattern increasing the morbidity and mortality. Drug therapy is commonly necessary and as first line-drugs are used the converting-enzyme inhibitors, the agiotensin-II receptors antagonists, and the antagonists-calcium, although the low-dose thiacidic diuretics.

  3. The Effect of High Dose Cholecalciferol on Arterial Stiffness and Peripheral and Central Blood Pressure in Healthy Humans

    DEFF Research Database (Denmark)

    Bressendorff, Iain; Brandi, Lisbet; Schou, Morten

    2016-01-01

    and central blood pressure and 24-hour ambulatory blood pressure. RESULTS: 22 subjects in the cholecalciferol arm and 18 subjects in the placebo arm completed the 16 weeks of follow-up. There was no difference in changes in PWV, AIx corrected for heart rate or central or peripheral blood pressure between...... and blood pressure in healthy normotensive adults. METHODS: 40 healthy adults were randomised in this double-blinded study to either oral cholecalciferol 3000 IU/day or matching placebo and were followed for 16 weeks to examine any effects on pulse wave velocity (PWV), augmentation index (AIx), peripheral...... the two groups. There was no correlation between serum 25-hydroxy vitamin D and any of these parameters. CONCLUSIONS: Oral cholecalciferol 3000 IU/day does not affect arterial stiffness or blood pressure after 16 weeks of treatment in healthy normotensive adults. TRIAL REGISTRATION: ClinicalTrials.gov NCT...

  4. Investigation of blood flow rheology using second-grade viscoelastic model (Phan-Thien-Tanner) within carotid artery.

    Science.gov (United States)

    Ramiar, Abas; Larimi, Morsal Momenti; Ranjbar, Ali Akbar

    2017-01-01

    Hemodynamic factors, such as Wall Shear Stress (WSS), play a substantial role in arterial diseases. In the larger arteries, such as the carotid artery, interaction between the vessel wall and blood flow affects the distribution of hemodynamic factors. The fluid is considered to be non-Newtonian, whose flow is governed by the equation of a second-grade viscoelastic fluid and the effects of viscoelastic on blood flow in carotid artery is investigated. Pulsatile flow studies were carried out in a 3D model of carotid artery. The governing equations were solved using finite volume C++ based on open source code, OpenFOAM. To describe blood flow, conservation of mass and momentum, a constitutive relation of simplified Phan-Thien-Tanner (sPTT), and appropriate relations were used to explain shear thinning behavior. The first recirculation was observed at t = 0.2 s, in deceleration phase. In the acceleration phase from t = 0.3 s to t = 0.5 s, vortex and recirculation sizes in bulb regions in both ECA and ICA gradually increased. As is observed in the line graphs based on extracted data from ICA, at t = 0.2 s, τyy is the maximum amount of wall shear stress and τxy the minimum one. The maximum shear stress occurred in the inner side of the main branch (inner side of ICA and ECA) because the velocity of blood flow in the inner side of the bulb region was maximum due to the created recirculation zone in the opposite side in this area. The rheology of blood flow and shear stress in various important parts (the area that are in higher rates of WSS such as bifurcation region and the regions after bulb areas in both branches, Line1-4 in Fig. 7) were also analyzed. The investigation of velocity stream line, velocity profile and shear stress in various sections of carotid artery showed that the maximum shear stress occurred in acceleration phase and in the bifurcation region between ECA and ICA which is due to velocity gradients and changes in thinning behavior of blood and

  5. N-isopropyl-4-[123I]iodoamphetamine (123I-IMP) products. A difference in radiochemical purity, unmetabolized fraction, and octanol extraction fraction in arterial blood and regional brain uptake in rats

    International Nuclear Information System (INIS)

    Kanai, Yasukazu; Hasegawa, Shinji; Kimura, Yasuyuki; Oku, Naohiko; Hatazawa, Jun; Ito, Hiroshi; Fukuda, Hiroshi

    2007-01-01

    N-isopropyl-4-[ 123 I]iodoamphetamine ( 123 I-IMP) is a lipophilic compound utilized for cerebral blood flow (CBF) measurement with single photon emission computed tomography (SPECT). Two different 123 I-IMP products (IMP A and IMP B ) are commercially available. We examined the radiochemical purity, unmetabolized fraction, and octanol extraction fraction in arterial blood, and the regional brain uptake of IMP A and IMP B in a rat model. IMP B (96.4%±0.08%, P A (95.5%±0.20%). The mean unmetabolized fraction in arterial blood taken at 10 min after intravenous administration of IMP B (69.5%±4.4%, P A (59.6%±2.6%). The mean octanol extraction fraction of IMP B (75.0%±1.3%, P A (67.2%±0.8%). The mean levels of radioactivity in arterial blood sampled at 10 min after injection and mean regional brain radioactivity (cerebral cortices, basal ganglia, brain stem, and cerebellum) at 10-12 min after injection were not significantly different between IMP A and IMP B . The present study indicates differences in the radiochemical purity and the unmetabolized and octanol extraction fraction in arterial blood between the two commercially available 123 I-IMP products. The appropriate octanol extraction fractions for IMP A and IMP B should be determined in humans and employed for quantitative CBF measurement in clinical SPECT. (author)

  6. Variability of carotid artery measurements on 3-Tesla MRI and its impact on sample size calculation for clinical research.

    Science.gov (United States)

    Syed, Mushabbar A; Oshinski, John N; Kitchen, Charles; Ali, Arshad; Charnigo, Richard J; Quyyumi, Arshed A

    2009-08-01

    Carotid MRI measurements are increasingly being employed in research studies for atherosclerosis imaging. The majority of carotid imaging studies use 1.5 T MRI. Our objective was to investigate intra-observer and inter-observer variability in carotid measurements using high resolution 3 T MRI. We performed 3 T carotid MRI on 10 patients (age 56 +/- 8 years, 7 male) with atherosclerosis risk factors and ultrasound intima-media thickness > or =0.6 mm. A total of 20 transverse images of both right and left carotid arteries were acquired using T2 weighted black-blood sequence. The lumen and outer wall of the common carotid and internal carotid arteries were manually traced; vessel wall area, vessel wall volume, and average wall thickness measurements were then assessed for intra-observer and inter-observer variability. Pearson and intraclass correlations were used in these assessments, along with Bland-Altman plots. For inter-observer variability, Pearson correlations ranged from 0.936 to 0.996 and intraclass correlations from 0.927 to 0.991. For intra-observer variability, Pearson correlations ranged from 0.934 to 0.954 and intraclass correlations from 0.831 to 0.948. Calculations showed that inter-observer variability and other sources of error would inflate sample size requirements for a clinical trial by no more than 7.9%, indicating that 3 T MRI is nearly optimal in this respect. In patients with subclinical atherosclerosis, 3 T carotid MRI measurements are highly reproducible and have important implications for clinical trial design.

  7. Arterial blood supply to the thalamus and midbrain on CT sections, 2

    International Nuclear Information System (INIS)

    Takeshita, Gen; Ottomo, Michinori; Satoh, Nobuko; Yokoyama, Yoshiaki.

    1984-01-01

    The selective injection of a dyestuff into thalamoperforating arteries from the posterior part of the circle of Willis, using five postmortem brains, was performed. After fixation, sections parallel to the orbito-meatal line were obtained. In cases which showed a standard development of the posterior communicating arteries, the usual patterns were as follows: the area supplied by perforators of the posterior communicating artery (anterior thalamoperforating artery) was visualized in the hypothalamus and the antero-lateral part of the thalamus; the area supplied by perforators of the proximal segment of the posterior cerebral artery (interpeduncular thalamoperforating artery) was visualized in the midbrain and the medial part of thalamus; the area supplied by perforators of the ambient segment of the posterior cerebral artery (thalamogeniculate artery) was visualized in the medial part of the geniculate body and the posterior part of the thalamus. According to the development of the posterior communicating artery, the area supplied by each perforator was quite variable. Three CT sections were obtained containing three different patterns of the posterior communicating artery: 1) well-developed; 2) moderately developed; and 3) poorly developed. The identification of the area supplied by thalamoperforating arteries on CT sections was quite useful in the CT diagnosis of cerebrovascular disorders which involved the thalamus and the midbrain. (author)

  8. Peripheral Blood Lymphocyte Depletion After Hepatic Arterial {sup 90}Yttrium Microsphere Therapy for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Carr, Brian I., E-mail: brianicarr@hotmail.com [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA and Department of Nutrition and Exptl Biology, Saverio De Bellis Medical Research Institute, Castellana Grotte, Bari (Italy); Metes, Diana M. [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA and Department of Nutrition and Exptl Biology, Saverio De Bellis Medical Research Institute, Castellana Grotte, Bari (Italy)

    2012-03-01

    Purpose: The short- and long-term effects of {sup 90}Yttrium microspheres therapy for hepatocellular carcinoma (HCC) on peripheral blood lymphocytes are unknown and were therefore examined. Methods and Materials: Ninety-two HCC patients were enrolled in a {sup 90}Yttrium therapy study and routine blood counts were examined as part of standard clinical monitoring. Results: We found an early, profound, and prolonged lymphopenia. In a subsequent cohort of 25 additional HCC patients, prospective flow cytometric immune-monitoring analysis was performed to identify specific changes on distinct lymphocyte subsets (i.e., CD3, CD4, CD8 T, and CD19 B lymphocytes) and NK cells absolute numbers, in addition to the granulocytes and platelets subsets. We found that the pretreatment lymphocyte subset absolute numbers (with the exception of NK cells) had a tendency to be lower compared with healthy control values, but no significant differences were detected between groups. Posttherapy follow-up revealed that overall, all lymphocyte subsets, except for NK cells, were significantly (>50% from pretherapy values), promptly (as early as 24 h) and persistently (up to 30 months) depleted post-{sup 90}Yttrium microspheres therapy. In contrast, granulocytes increased rapidly (24 h) to compensate for lymphocyte depletion, and remained increased at 1-year after therapy. We further stratified patients into two groups, according to survival at 1 year. We found that lack of recovery of CD19, CD3, CD8, and especially CD4 T cells was linked to poor patient survival. No fungal or bacterial infections were noted during the 30-month follow-up period. Conclusions: The results show that lymphocytes (and not granulocytes, platelets, or NK cells) are sensitive to hepatic arterial {sup 90}Yttrium without associated clinical toxicity, and lack of lymphocyte recovery (possibly leading to dysregulation of adaptive cellular immunity) posttherapy indicates poor survival.

  9. Gradient changes in porcine renal arterial vascular anatomy and blood flow after cryoablation.

    Science.gov (United States)

    Lagerveld, Brunolf W; van Horssen, Pepijn; Laguna, M Pilar; van den Wijngaard, Jeroen P H M; Siebes, Maria; Wijkstra, Hessel; de la Rosette, Jean J M C H; Spaan, Jos A E

    2011-08-01

    We quantified temporal changes in vascular structure and blood flow after cryosurgery of the porcine kidney in vivo. We studied 5 groups of 4 kidneys each with a survival time of 20 minutes, 4 hours, 2 days, and 1 and 2 weeks after cryoablation, respectively. Before harvesting the kidneys, fluorescently labeled microspheres were administrated in the descending aorta. After harvest the kidney and its vasculature were casted with fluorescently dyed elastomer, frozen and processed in an imaging cryomicrotome to reveal the 3-dimensional arterial branching structure and microsphere distribution. In regions of interest vessels were segmented by image analysis software and histograms were constructed to reveal the total summed vessel length as a function of diameter. A characteristic diameter of the ablated area was measured. The 20-minute survival group histograms showed a significant shift of the peak to larger diameters (p<0.002), indicating that smaller vessels were destroyed. Microsphere density was decreased to 2% in the ablated region but not in the nonablated border zone, depending on the remaining crater crossing larger vessels. After 2 weeks neither vessels nor microspheres were left in the ablated area, which had shrunk by about 40% in diameter. Study limitations are the lack of histological confirmation and the use of normal rather than cancerous tissue. Larger vessels remain patent just after ablation and transport blood to the border of the ablation crater but perfusion within the crater is halted instantly. Characteristic crater diameter increases initially but decreases thereafter. Destruction of vessels and tissue is complete 2 weeks after cryoablation. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Endothelial Injury Associated with Cold or Warm Blood Cardioplegia during Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Elmar W. Kuhn

    2015-01-01

    Full Text Available The aim of this investigation was to analyze the impact of intermittent cold blood cardioplegia (ICC and intermittent warm blood cardioplegia (IWC on endothelial injury in patients referred to elective on-pump coronary artery bypass graft (CABG surgery. Patients undergoing CABG procedures were randomized to either ICC or IWC. Myocardial injury was assessed by CK-MB and cardiac troponin T (cTnT. Endothelial injury was quantified by circulating endothelial cells (CECs, von Willebrand factor (vWF, and soluble thrombomodulin (sTM. Perioperative myocardial injury (PMI and major adverse cardiac events (MACE were recorded. Demographic data and preoperative risk profile of included patients (ICC: n=32, IWC: n=36 were comparable. No deaths, PMI, or MACE were observed. Levels of CK-MB and cTnT did not show intergroup differences. Concentrations of CECs peaked at 6 h postoperatively with significantly higher values for IWC-patients at 1 h (ICC: 10.1 ± 3.9/mL; IWC: 18.4 ± 4.1/mL; P=0.012 and 6 h (ICC: 19.3 ± 6.2/mL; IWC: 29.2 ± 6.7/mL; P<0.001. Concentrations of vWF (ICC: 178.4 ± 73.2 U/dL; IWC: 258.2 ± 89.7 U/dL; P<0.001 and sTM (ICC: 3.2 ± 2.1 ng/mL; IWC: 5.2 ± 2.4 ng/mL; P=0.011 were significantly elevated in IWC-group at 1 h postoperatively. This study shows that the use of IWC is associated with a higher extent of endothelial injury compared to ICC without differences in clinical endpoints.

  11. Predictive Model for Blood Product Use in Coronary Artery Bypass Grafting

    International Nuclear Information System (INIS)

    Sharif, H.; Ansari, H.Z.; Ashfaq, A.; Rawasia, W.F.; Bano, G.; Hashmi, S.

    2016-01-01

    Objective: To build a clinical predictive model to determine the need for transfusing blood and its products in coronary artery bypass grafting (CABG) procedures in South East Asian population. Study Design: Analytical study. Place and Duration of Study: Section of Cardiothoracic Surgery, Aga Khan University Hospital, Karachi, from January 2006 to October 2014. Methodology: Information on pre-, intra- and postoperative variables were collected for all adult patients who underwent on-pump CABG. The patients grouped into those who received blood and its components, and those who did not. A univariate as well as multivariate logistic model was built to determine the predictors of transfusion. Result: A total of 3,550 patients underwent CABG and males were dominant in both groups (75 vs. 93 percent). The transfusion rate was 56.4 percent (n=2001). Age (adjusted OR 1.03, p < 0.001), obesity (1.50, p=0.001), tobacco use (1.29, p=0.001), and male gender (4.51, p < 0.001) found to be a stronger predictor. Among preoperative comorbidities, diabetes (1.20, p=0.016), myocardial infarction (1.22, p=0.009), preoperative creatinine (1.12, p=0.033), and left main vessel disease of > 50 percent (1.49, p < 0.001) were independently associated with the outcome. Compared to elective cases, transfusion rates were high in urgent and emergent cases (OR: 1.93 and 3.36 respectively, p < 0.001 for both). Conclusion: Age, male gender, obesity, tobacco use, diabetes, myocardial infarction, high creatinine, urgent and emergent cases were independent predictors of transfusion in CABG procedure. This model can be utilized for preoperative risk stratification of patients and their management to improve the outcomes. (author)

  12. Blood Transfusion and 30-Day Mortality in Patients With Coronary Artery Disease and Anemia Following Noncardiac Surgery.

    Science.gov (United States)

    Hollis, Robert H; Singletary, Brandon A; McMurtrie, James T; Graham, Laura A; Richman, Joshua S; Holcomb, Carla N; Itani, Kamal M; Maddox, Thomas M; Hawn, Mary T

    2016-02-01

    Although liberal blood transfusion thresholds have not been beneficial following noncardiac surgery, it is unclear whether higher thresholds are appropriate for patients who develop postoperative myocardial infarction (MI). To evaluate the association between postoperative blood transfusion and mortality in patients with coronary artery disease and postoperative MI following noncardiac surgery. Retrospective cohort study involving Veterans Affairs facilities from January 1, 2000, t