WorldWideScience

Sample records for argon

  1. Depleted Argon from Underground Sources

    International Nuclear Information System (INIS)

    Argon is a strong scintillator and an ideal target for Dark Matter detection; however 39Ar contamination in atmospheric argon from cosmic ray interactions limits the size of liquid argon dark matter detectors due to pile-up. Argon from deep underground is depleted in 39Ar due to the cosmic ray shielding of the earth. In Cortez, Colorado, a CO2 well has been discovered to contain approximately 600 ppm of argon as a contamination in the CO2. We first concentrate the argon locally to 3% in an Ar, N2, and He mixture, from the CO2 through chromatographic gas separation, and then the N2 and He will be removed by continuous distillation to purify the argon. We have collected 26 kg of argon from the CO2 facility and a cryogenic distillation column is under construction at Fermilab to further purify the argon.

  2. Argon in action

    CERN Multimedia

    Corinne Pralavorio

    2015-01-01

    Over the past few days, the SPS has been accelerating argon ions, which have started to be sent to the NA61/SHINE experiment. This operating mode, using a new type of ion, required a number of modifications to the accelerator.   Picture 1: a “super-cycle” of the SPS, featuring a proton cycle for the LHC, followed by an argon ion cycle for the North Area. Today, the accelerators are once again juggling particles and even performing completely new tricks. The SPS is supplying beams of argon ions for the first time, at energies never before achieved for this type of beam. They are destined for the NA61/SHINE experiment (see box) located in the North Area, which began receiving the beams on 11 February. Argon ions have a relatively large mass, as they consist of 40 nucleons, so they can be used in a similar way to lead ions. The main difficulty in accelerating them lies in the SPS, where the variation in acceleration frequency is limited. “The SPS was designed for a...

  3. Thermophysical properties of argon

    Energy Technology Data Exchange (ETDEWEB)

    Jaques, A.

    1988-02-01

    The entire report consists of tables of thermodynamic properties (including sound velocity, thermal conductivity and diffusivity, Prandtl number, density) of argon at 86 to 400/degree/K, in the form of isobars over 0.9 to 100 bars. (DLC)

  4. Liquid argon neutrino detectors

    CERN Document Server

    Battistoni, G

    2001-01-01

    The liquid argon imaging technique, as proposed for the ICARUS detector, offers the possibility to perform complementary and simultaneous measurements of neutrinos, as those of CERN to Gran Sasso beam (CNGS) and those from cosmic ray events. For the currently allowed values of the Super-Kamiokande results, the combination of both CNGS and atmospheric data will provide a precise determination of the oscillation parameters. Since one can observe and unambiguously identify nu /sub e/, nu /sub mu / and nu /sub tau / components, this technology allows to explore the full (3*3) mixing matrix. The same class of detector can be proposed for high precision measurements at a neutrino factory. (3 refs).

  5. Isentropic compression of argon

    Energy Technology Data Exchange (ETDEWEB)

    Veeser, L.R.; Ekdahl, C.A.; Oona, H. [and others

    1997-06-01

    The compression was done in an MC-1 flux compression (explosive) generator, in order to study the transition from an insulator to a conductor. Since conductivity signals were observed in all the experiments (except when the probe is removed), both the Teflon and the argon are becoming conductive. The conductivity could not be determined (Teflon insulation properties unknown), but it could be bounded as being {sigma}=1/{rho}{le}8({Omega}cm){sub -1}, because when the Teflon breaks down, the dielectric constant is reduced. The Teflon insulator problem remains, and other ways to better insulate the probe or to measure the conductivity without a probe is being sought.

  6. Depleted argon from underground sources

    Energy Technology Data Exchange (ETDEWEB)

    Back, H.O.; /Princeton U.; Alton, A.; /Augustana U. Coll.; Calaprice, F.; Galbiati, C.; Goretti, A.; /Princeton U.; Kendziora, C.; /Fermilab; Loer, B.; /Princeton U.; Montanari, D.; /Fermilab; Mosteiro, P.; /Princeton U.; Pordes, S.; /Fermilab

    2011-09-01

    Argon is a powerful scintillator and an excellent medium for detection of ionization. Its high discrimination power against minimum ionization tracks, in favor of selection of nuclear recoils, makes it an attractive medium for direct detection of WIMP dark matter. However, cosmogenic {sup 39}Ar contamination in atmospheric argon limits the size of liquid argon dark matter detectors due to pile-up. The cosmic ray shielding by the earth means that Argon from deep underground is depleted in {sup 39}Ar. In Cortez Colorado a CO{sub 2} well has been discovered to contain approximately 500ppm of argon as a contamination in the CO{sub 2}. In order to produce argon for dark matter detectors we first concentrate the argon locally to 3-5% in an Ar, N{sub 2}, and He mixture, from the CO{sub 2} through chromatographic gas separation. The N{sub 2} and He will be removed by continuous cryogenic distillation in the Cryogenic Distillation Column recently built at Fermilab. In this talk we will discuss the entire extraction and purification process; with emphasis on the recent commissioning and initial performance of the cryogenic distillation column purification.

  7. The Liquid Argon Purity Demonstrator

    CERN Document Server

    Adamowski, M; Dvorak, E; Hahn, A; Jaskierny, W; Johnson, C; Jostlein, H; Kendziora, C; Lockwitz, S; Pahlka, B; Plunkett, R; Pordes, S; Rebel, B; Schmitt, R; Stancari, M; Tope, T; Voirin, E; Yang, T

    2014-01-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  8. The Liquid Argon Purity Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Adamowski, M.; Carls, B.; Dvorak, E.; Hahn, A.; Jaskierny, W.; Johnson, C.; Jostlein, H.; Kendziora, C.; Lockwitz, S.; Pahlka, B.; Plunkett, R.; Pordes, S.; Rebel, B.; Schmitt, R.; Stancari, M.; Tope, T.; Voirin, E.; Yang, T.

    2014-07-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  9. Fano factor in pure argon

    International Nuclear Information System (INIS)

    The Fano factor for 5.3 MeV alpha particles in pure argon has been measured with a gridded ionization chamber and estimated to be 0.20 (+0.01-0.02). The obtained value is consistent with the theoretical value if the contribution of elastic nuclear collisions to the Fano factor is taken into the consideration. There is no appreciable difference between the values for pure argon and for a gas mixture of Ar (10%)CH4 obtained in the previous measurement. (orig.)

  10. Attainable superheat of argon-helium, argon-neon solutions.

    Science.gov (United States)

    Baidakov, Vladimir G; Kaverin, Aleksey M; Andbaeva, Valentina N

    2008-10-16

    The method of lifetime measurement has been used to investigate the kinetics of spontaneous boiling-up of superheated argon-helium and argon-neon solutions. Experiments were made at a pressure of p = 1.5 MPa and concentrations up to 0.33 mol% in the range of nucleation rates from 10 (4) to 10 (8) s (-1) m (-3). The homogeneous nucleation regime has been distinguished. With good agreement between experimental data and homogeneous nucleation theory in temperature and concentration dependences of the nucleation rate, a systematic underestimation by 0.25-0.34 K has been revealed in superheat temperatures over the saturated line attained by experiment as compared with theoretical values calculated in a macroscopic approximation. The revealed disagreement between theory and experiment is connected with the dependence of the properties of new-phase nuclei on their size.

  11. Binocular indirect argon laser photocoagulator.

    OpenAIRE

    Mizuno, K

    1981-01-01

    The binocular indirect argon laser photocoagulator was newly designed to enable visualisation of the entire fundus during panretinal laser photocoagulation and to treat retinal tears immediately after buckling procedures of the sclera. The lamp housing of the binocular ophthalmoscope was remodelled and adjusted so that the laser beam and illuminating light are coaxial after leaving the ophthalmoscope. The blocking filter was permanently fixed in the eye-pieces to lighten the weight of the oph...

  12. Liquid Argon Barrel Cryostat Arrived

    CERN Multimedia

    Pailler, P

    Last week the first of three cryostats for the ATLAS liquid argon calorimeter arrived at CERN. It had travelled for 46 days over several thousand kilometers from Japan to CERN. During three years it has been fabricated by Kawasaki Heavy Industries Ltd. at Harima, close to Kobe, under contract from Brookhaven National Laboratory (BNL) of the U.S.. This cryostat consists of two concentric cylinders made of aluminium: the outer vacuum vessel with a diameter of 5.5 m and a length of 7 m, and the inner cold vessel which will contain the electromagnetic barrel calorimeter immersed in liquid argon. The total weight will be 270 tons including the detectors and the liquid argon. The cryostat is now located in building 180 where it will be equipped with 64 feed-throughs which serve for the passage of 122,880 electrical lines which will carry the signals of the calorimeter. After integration of the calorimeter, the solenoidal magnet of ATLAS will be integrated in the vacuum vessel. A final cold test of the cryostat inc...

  13. Composing Experimental Environment of PRIDE Argon cell

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Seonho; Jang, Yongkuk; Cho, Il Je [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In PRIDE depleted Uranium feed material and a depleted Uranium mixed with some surrogate material are used for performing engineering scale Pyroprocessing. PRIDE has to maintain inert atmosphere because of the characteristic of Electrolytic Reduction technology, Electro refining technology, Electrowinning technology. The impurity concentration of the Argon cell has to be under 50 ppm(Oxygen, moisture). Atmospheric pressure changes and temperature changes can affect the Argon cell's impurity concentration. In this paper, how to compose the Argon cell impurity concentration under 50 ppm to make the exact optimal experimental environment(Oxygen, moisture) will be introduced. Composing the exact optimal experimental environment by supplying Argon gas have been introduced in this paper. Continuously supplying Argon gas which is heavier than the Oxygen through the bottom of the Argon cell the oxygen eventually discharged through the high vent fan and lower the impurity concentration of Oxygen.

  14. Transition probabilities for argon I

    International Nuclear Information System (INIS)

    Transition probabilities for ArI lines have been calculated on the basis of the (j,k)-coupling scheme for more than 16000 spectral lines belonging to the transition arrays 4s-np (n=4 to n=9), 5s-np (n=5 to n=9), 6s-np (n=6 to n=9), 7s-np (n=8 to n=9), 4p-ns (n=5 to n=10), 5p-ns (n=6 to n=9), 6p-ns (n=7 to n=8), 4p-nd (n=3 to n=9), 5p-nd (n=4 to n=9), 3d-np (n=5 to n=9), 4d-np (n=6 to n=9), 5d-np (n=7 to n=9), 3d-nf (n=4 to n=9), 4d-nf (n=4 to n=9), 5d-nf (n=5 to n=9), 4f-nd (n=5 to n=9) 5f-nd (n=6 to n=9), 4f-ng (n=5 to n=9), 5f-ng (n=6 to n=9). Inso far as values by other authors exist, comparison is made with these values. It turns out that the results obtained in (j,k)-coupling are close to those obtained in intermediate coupling except for intercombination lines. For high principal and/or orbital quantum numbers the transition probabilities for a multiplet approach those of the corresponding transitions in atomic hydrogen. The calculated values are applied to construct a simplified argon-atom model, which reflects the real transition properties and which allows simplified but realistic non-equilibrium calculations for argon plasmas which deviate from local thermodynamic equilibrium (LTE)

  15. Opacity of Shock-Generated Argon Plasmas

    Institute of Scientific and Technical Information of China (English)

    王藩侯; 陈敬平; 周显明; 李西军; 经福谦; 孟续军; 孙永盛

    2001-01-01

    Argon plasmas with uniform density and temperature are generated by a planar shock wave through argon gas. The opacities of argon plasma, covering the thermodynamic states at temperatures of 1.4-2.2eV and in densities of 0.0083- 0.015 g/cm3, are investigated by measuring the emitted radiance versus time at several visible wavelengths. Comparison of the measured opacities with those calculated demonstrates that the average atom model can be used well to describe the essential transport behaviour of photons in argon plasma under the abovementioned thermodynamic condition. A simplified and self-consistent method to deduce the reflectivity R(λ) at the baseplate surface is applied. It demonstrates that the values of R(λ) are all around 0.4 in the experiments, which are basically in agreement with those given by Erskine previously (1994 J. Quant. Spectrosc. Radiat.Transfer 51 97).

  16. Status and perspecitves of liquid argon calorimeters

    International Nuclear Information System (INIS)

    The status of liquid argon calorimeters is reviewed, and experience obtained with these devices is described. Future perspectives of the liquid ionization chamber technique in calorimetry are also discussed. (orig.)

  17. Clinical periodontics with the argon laser

    Science.gov (United States)

    Finkbeiner, R. L.

    1995-04-01

    The argon laser has proven to be a valuable tool for the thermodynamic debridement of the periodontal lesion, incisions and tissue fusion. Illustrations of clinical applications and discussion of laser parameters will be provided.

  18. Argon plasma irradiation of polypropylene

    Energy Technology Data Exchange (ETDEWEB)

    Slepicka, P., E-mail: petr.slepicka@vscht.c [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic); Vasina, A. [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic); Kolska, Z. [J.E. Purkyne University, Department of Chemistry, 40096 Usti Nad Labem (Czech Republic); Luxbacher, T. [Anton Paar GmbH, 8054 Graz (Austria); Malinsky, P.; Mackova, A. [Nuclear Physics Institute of Academy of Sciences of the Czech Republic, 25068 Rez (Czech Republic); Svorcik, V. [Department of Solid State Engineering, Institute of Chemical Technology, 16628 Prague (Czech Republic)

    2010-06-15

    Polypropylene samples were exposed to argon plasma discharge and the changes of the PP surface properties were studied by different methods. Surface wettability was derived from contact angle measured by standard goniometry and chemical structure of the plasma modified PP was studied using X-ray photoelectron spectroscopy (XPS) and by Rutherford backscattering spectroscopy (RBS), surface morphology and roughness of samples using AFM. Zeta potential of pristine and modified PP was determined with the SurPASS. The presence of incorporated oxygen in the PP surface layer, about 60 nm thick, was observed in RBS spectra. Oxygen concentration is a decreasing function of the depth. With progressing aging time the oxygen concentration on the PP surface decreases. Plasma treatment results in a rapid decrease of the contact angle, which increases again with increasing aging time. In XPS measurement the oxygen containing structures, created by the plasma treatment, were found on the very surface of the modified PP and the zeta potential being changed too. The significant difference in zeta potential between pristine and plasma treated PP clearly indicates that the plasma treatment leads to a more hydrophilic PP surface.

  19. Negative corona current pulses in argon and in mixture argon with SF6

    International Nuclear Information System (INIS)

    Waveforms of the first negative current pulses in a short negative point-to plane gap in pure argon and argon with SF6 admixture have been investigated with a nanosecond time resolution at a gas pressure 50 kPa as a function of applied gap voltage and content of SF6 in the mixture. We have made an attempt to explain the differences in the discharge development in pure argon and in argon with admixture of SF6 based on the observed changes of the pulse shape. The experimental results obtained will be discussed in context with existing computer simulation models (Authors)

  20. Measurements on scintillation light from liquid argon

    International Nuclear Information System (INIS)

    It is shown that an argon calorimeter can operate as a scintillation detector, provided that xenon is added. With the addition of 170 ppm xenon a light yield of 70% has been obtained. In addition the light yield is determined under influence of an electric field, from differently ionising particles and by the use of aluminium mirrors acting as light guides. Finally first measurements with a photomultiplier working at liquid argon temperatures are reported. (orig.)

  1. Argon Laser Photoablation for Postburn Conjunctival Pigmentation

    Directory of Open Access Journals (Sweden)

    Seong Joon Ahn

    2014-01-01

    Full Text Available We report a case of an ocular burn injury from boiling water which resulted in conjunctival pigmentation, 1 week following injury. For cosmetic purposes, 2 sessions of argon laser photoablation were performed. One month after laser treatment, conjunctival pigmentation had been successfully removed and the patient was very satisfied with the results. Argon laser photoablation may be an effective way to remove postburn conjunctival pigmentation.

  2. Argon clusters embedded in helium nanodroplets.

    Science.gov (United States)

    da Silva, Filipe Ferreira; Bartl, Peter; Denifl, Stephan; Echt, Olof; Märk, Tilmann D; Scheier, Paul

    2009-11-14

    Electron impact ionization of argon clusters embedded in helium droplets is investigated. Superior mass resolution makes it possible to distinguish between nominally isobaric cluster ions. An abundance maximum for ArHe(12)(+) is unambiguously confirmed; the spectra also prove the formation of Ar(2)He(n)(+) complexes that had been claimed to fragment into pure Ar(2)(+). Distributions of larger argon cluster ions containing up to 60 atoms closely resemble distributions observed upon electron impact or photoionization of bare argon clusters; caging and evaporative cooling provided by the helium matrix do not suffice to quench fragmentation of the nascent argon cluster ions. Intriguing abundance anomalies are observed in distributions of argon cluster ions that contain water, nitrogen or oxygen impurities. The strong abundance of Ar(55)H(2)O(+), Ar(54)O(2)(+) and Ar(54)N(2)(+) contrasts with the virtual absence of slightly larger cluster ions containing the corresponding impurities. The features are probably related to enhanced cluster ion stability upon closure of the second icosahedral shell but the difference in magic numbers (54 versus 55) and the well-known reactivity of charged argon-nitrogen complexes suggest structural differences. PMID:19851558

  3. Potassium-argon/argon-40-argon-39 geochronology of Cenozoic alkali basalts from the South China Sea

    Institute of Scientific and Technical Information of China (English)

    YAN Quanshu; SHI Xuefa; YANG Yaomin; WANG Kunshan

    2008-01-01

    Based on the isotopic chronologic results of Cenozoic alkali basalts from the South China Sea,the characteristics of volcanic activi-ty of the South China Sea after spreading were studied.The potassium - argon ages of eight alkali basalt samples from the South China Sea,and the argon - argon ages of two samples among them are reported.Apparent ages of the whole rock are 3.80 to 7.91 Ma with an average value of 5.43 Ma (potassium- argon,whole rock),and there is little difference among samples at the same location,e.g.,4.76~5.78 Ma for location S04-12.The argon - argon ages for the two samples are 6.06 and 4.71 Ma,which lie within the age scope of potassium - argon method.The dating results indicate that rock-forming age is from late Miocene to Pli-ocene,which is consistent with erupting event for alkali basalts from adjacent regions of the South China Sea.Volcanic activities occur after the cessation of spreading of the South China Sea,which are controlled by lithospheric fault and the spreading center formed during the spreading period of the South China Sea.These dating results,combined with geochemical characteristics of these basalts,the published chronological data for the South China Sea and its adjacent regions,and the updated geophysical data near Hainan Island,suggest that after the cessation of spreading of the South China Sea,there occur widely distributing magmatic activities which primarily is alkali basalt,and the volcanic activity continues to Quaternary.The activity may be relative to Hainan mantle plume originated from core/mantle boundary.

  4. Argon Collection And Purification For Proliferation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Achey, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hunter, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-09

    In order to determine whether a seismic event was a declared/undeclared underground nuclear weapon test, environmental samples must be taken and analyzed for signatures that are unique to a nuclear explosion. These signatures are either particles or gases. Particle samples are routinely taken and analyzed under the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) verification regime as well as by individual countries. Gas samples are analyzed for signature gases, especially radioactive xenon. Underground nuclear tests also produce radioactive argon, but that signature is not well monitored. A radioactive argon signature, along with other signatures, can more conclusively determine whether an event was a nuclear test. This project has developed capabilities for collecting and purifying argon samples for ultra-low-background proportional counting. SRNL has developed a continuous gas enrichment system that produces an output stream containing 97% argon from whole air using adsorbent separation technology (the flow diagram for the system is shown in the figure). The vacuum swing adsorption (VSA) enrichment system is easily scalable to produce ten liters or more of 97% argon within twelve hours. A gas chromatographic separation using a column of modified hydrogen mordenite molecular sieve has been developed that can further purify the sample to better than 99% purity after separation from the helium carrier gas. The combination of these concentration and purification systems has the capability of being used for a field-deployable system for collecting argon samples suitable for ultra-low-background proportional counting for detecting nuclear detonations under the On-Site Inspection program of the CTBTO verification regime. The technology also has applications for the bulk argon separation from air for industrial purposes such as the semi-conductor industry.

  5. Attenuation of vacuum ultraviolet light in liquid argon

    CERN Document Server

    Neumeier, A; Oberauer, L; Potzel, W; Schönert, S; Dandl, T; Heindl, T; Ulrich, A; Wieser, J

    2015-01-01

    The transmission of liquid argon has been measured, wavelength resolved, for a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation length is presented for pure argon. It is shown that no universal wavelength independent attenuation length can be assigned to liquid argon for its own fluorescence light due to the interplay between the wavelength dependent emission and absorption. A decreasing transmission is observed below 130 nm in both chemically cleaned and distilled liquid argon and assigned to absorption by the analogue of the first argon excimer continuum. For not perfectly cleaned argon a strong influence of impurities on the transmission is observed. Two strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm width, respectively, are assigned to traces of xenon in argon. A broad absorption region below 180 nm is found for unpurified argon and tentatively attributed to the presence of water in the argon sample.

  6. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    International Nuclear Information System (INIS)

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field

  7. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    CERN Document Server

    Creus, W; Amsler, C; Ferella, A D; Rochet, J; Scotto-Lavina, L; Walter, M

    2015-01-01

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field.

  8. Contraction ionization waves in the argon contracted discharge

    International Nuclear Information System (INIS)

    An investigation of ionization waves in the argon contracted discharge and a definition of their arising propagation mechanism accounting for the specificity of elementary pocesses characteristic of argon are presented. (author)

  9. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...

  10. Antiapoptotic activity of argon and xenon.

    Science.gov (United States)

    Spaggiari, Sabrina; Kepp, Oliver; Rello-Varona, Santiago; Chaba, Kariman; Adjemian, Sandy; Pype, Jan; Galluzzi, Lorenzo; Lemaire, Marc; Kroemer, Guido

    2013-08-15

    Although chemically non-reactive, inert noble gases may influence multiple physiological and pathological processes via hitherto uncharacterized physical effects. Here we report a cell-based detection system for assessing the effects of pre-defined gas mixtures on the induction of apoptotic cell death. In this setting, the conventional atmosphere for cell culture was substituted with gas combinations, including the same amount of oxygen (20%) and carbon dioxide (5%) but 75% helium, neon, argon, krypton, or xenon instead of nitrogen. The replacement of nitrogen with noble gases per se had no effects on the viability of cultured human osteosarcoma cells in vitro. Conversely, argon and xenon (but not helium, neon, and krypton) significantly limited cell loss induced by the broad-spectrum tyrosine kinase inhibitor staurosporine, the DNA-damaging agent mitoxantrone and several mitochondrial toxins. Such cytoprotective effects were coupled to the maintenance of mitochondrial integrity, as demonstrated by means of a mitochondrial transmembrane potential-sensitive dye and by assessing the release of cytochrome c into the cytosol. In line with this notion, argon and xenon inhibited the apoptotic activation of caspase-3, as determined by immunofluorescence microscopy coupled to automated image analysis. The antiapoptotic activity of argon and xenon may explain their clinically relevant cytoprotective effects. PMID:23907115

  11. Keeping argon under a graphene lid-Argon intercalation between graphene and nickel(111)

    Science.gov (United States)

    Späth, Florian; Gotterbarm, Karin; Amende, Max; Bauer, Udo; Gleichweit, Christoph; Höfert, Oliver; Steinrück, Hans-Peter; Papp, Christian

    2016-01-01

    We report on the intercalation of graphene grown on a Ni(111) crystal with argon. Argon is implanted in the Ni(111) crystal by ion bombardment before graphene growth, and diffuses to the surface during the growth of graphene at elevated temperatures. Graphene acts as an atomically thin barrier and keeps the argon underneath. We investigated this system with high resolution X-ray photoelectron spectroscopy. From our experiments we determined the mean quantities of argon under graphene. From our analysis, a simple model to determine the pressure under the graphene layer is presented. In our measurements, we find an increased thermal stability of the intercalated graphene as compared to non-intercalated graphene on Ni(111).

  12. Argon Laser Treatment of Strawberry Hemangioma in Infancy

    OpenAIRE

    Achauer, Bruce M.; Vander Kam, Victoria M.

    1985-01-01

    Argon laser therapy is effective for removing port-wine stains and for reducing cutaneous vascular and pigmented lesions. Strawberry hemangiomas, being much thicker lesions than port-wine stains, were considered not appropriate for argon laser treatment. Using argon laser therapy in 13 cases of strawberry hemangioma, we achieved poor to dramatic results.

  13. Argon laser treatment of strawberry hemangioma in infancy.

    Science.gov (United States)

    Achauer, B M; Vander Kam, V M

    1985-11-01

    Argon laser therapy is effective for removing port-wine stains and for reducing cutaneous vascular and pigmented lesions. Strawberry hemangiomas, being much thicker lesions than port-wine stains, were considered not appropriate for argon laser treatment. Using argon laser therapy in 13 cases of strawberry hemangioma, we achieved poor to dramatic results. PMID:4082569

  14. Flow Parameters of Argon plasma Discharge

    International Nuclear Information System (INIS)

    Owing to the viscosity, the plasma will be adhering to the inner surface of the outer electrode and outer surface of the inner one. As result that the discharge will be eroding the walls of coaxial system. The thickness of the boundary layer near the walls has been estimated at different positions from the breech of coaxial plasma gun. It is found that the thickness of layer 0.008 cm at the end of inner electrode (17 cm). A coaxial plasma gun device is operated in argon gas at ambient pressure 0.6 Torr and discharge voltage about 10 KV. The electron temperature of argon discharge has been determined by using spectroscopic technique. It is found that kTe=3.4 eV. By knowing the thickness of the boundary layer, the density can be determined. The Reynolds number R=105 and Mach number M=5 i.e. the flow is compressible and hypersonic

  15. Argon laser irradiation of the otolithic organ

    Energy Technology Data Exchange (ETDEWEB)

    Okuno, T.; Nomura, Y.; Young, Y.H.; Hara, M. (Univ. of Tokyo (Japan))

    1990-12-01

    An argon laser was used to irradiate the otolithic organs of guinea pigs and cynomolgus monkeys. After stapedectomy, the argon laser (1.5 W x 0.5 sec/shot) irradiated the utricle or saccule without touching the sensory organs. The stapes was replaced over the oval window after irradiation. The animals used for acute observation were killed immediately for morphologic studies; those used for long-term observation were kept alive for 2, 4, or 10 weeks. Acute observation revealed that sensory and supporting cells were elevated from the basement membrane only in the irradiated area. No rupture of the membranous labyrinth was observed. Long-term observation revealed that the otolith of the macula utriculi had disappeared in 2-week specimens. The entire macula utricili had disappeared in 10-week specimens. No morphologic changes were observed in cochlea, semicircular canals, or membranous labyrinth. The saccule showed similar changes.

  16. Abnormal epidermal changes after argon laser treatment

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, R.A.; Knobler, R.M.; Aberer, E.; Klein, W.; Kocsis, F.; Ott, E. (Univ. of Vienna (Austria))

    1991-02-01

    A 26-year-old woman with a congenital port-wine stain on the forehead was treated three times at 2-month intervals with an argon laser. Six months after the last treatment, moderate blanching and mild scaling confined to the treated area was observed. A biopsy specimen of the treated area revealed a significant decrease in ectatic vessels. However, epidermal changes similar to those of actinic keratosis with disorganized cell layers and marked cytologic abnormalities were seen. Analysis of peripheral blood lymphocytes for a defect in DNA repair was negative. Multiple, argon laser-induced photothermal effects may be responsible for the changes observed in our case and may lead to premalignant epidermal transformation.

  17. Explanation of the memory effect in argon

    Directory of Open Access Journals (Sweden)

    Marković Vidosav

    2005-01-01

    Full Text Available Memory effect - the long time variation of the electrical breakdown time delay on the relaxation time td (τ was observed in argon 24 hours after relaxation times and explained by the long-lived metastable states remaining from the preceding glow. However, the quenching processes reducing the effective lifetime of metastable states several orders of magnitude below that relevant for the time scale of observation were neglected. By applying approximate gas phase models it was found that the early afterglow kinetics up to hundreds of milliseconds is dominated by the decay of molecular argon ions Ar2+ and the approximate value of their ambipolar diffusion coefficient is determined. After that, nitrogen atoms present as impurities and recombined on the cathode surface and/or field emission determine the breakdown time delay down to the cosmic rays and natural radioactivity level.

  18. Anatomy of an Inversion - Argon Isotopes

    Science.gov (United States)

    Zamick, L.; Sharon, Y. Y.; Robinson, S. J. Q.

    2012-02-01

    Two different interactions give similar results for excitation energies and g factors of 2+1 states for most even-even argon isotopes except 46Ar. This is explained in terms of an inversion in J = ½+ and levels in 47K which is successfully obtained by one of the interactions but not the other. This example shows the possible dangers of nuclear astrophysics extrapolations.

  19. Development of a low-cost inductively coupled argon plasma

    International Nuclear Information System (INIS)

    The aim of this investigation is to drastically reduce running costs of an inductively coupled plasma. This is done by reducing the argon consumption from 20 l/min to about 1 l/min. First, a sample introduction system operating on 0.1 l/min of carrier argon is described. This system ensures a high ratio of plasma argon and carrier argon even at the low total argon consumptions intended. Next, the developed low consumption plasma is presented. In the proposed design, air is blown perpendicularly against the outside of the torch. A different coil has been developed to make air-cooling efficient. Preliminary data on coupling efficiency for the air-cooled plasma are presented. A similarly low argon consumption has been achieved with water as an external coolant medium. It is concluded that a cheaper alternative to the current ICP has become available. (Auth.)

  20. Effects of Nitrogen contamination in liquid Argon

    Science.gov (United States)

    Acciarri, R.; Antonello, M.; Baibussinov, B.; Baldo-Ceolin, M.; Benetti, P.; Calaprice, F.; Calligarich, E.; Cambiaghi, M.; Canci, N.; Carbonara, F.; Cavanna, F.; Centro, S.; Cocco, A. G.; Di Pompeo, F.; Fiorillo, G.; Galbiati, C.; Gallo, V.; Grandi, L.; Meng, G.; Modena, I.; Montanari, C.; Palamara, O.; Pandola, L.; Piano Mortari, G. B.; Pietropaolo, F.; Raselli, G. L.; Roncadelli, M.; Rossella, M.; Rubbia, C.; Segreto, E.; Szelc, A. M.; Ventura, S.; Vignoli, C.

    2010-06-01

    A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. The purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from ~ 10-1 ppm up to ~ 103 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (γ-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. Direct PMT signal acquisition exploiting high time resolution by fast waveform recording allowed high precision extraction of the main characteristics of the scintillation light emission in contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable starting from Script O(1 ppm) of Nitrogen concentrations. The rate constant of the quenching process induced by Nitrogen in liquid Ar has been found to be kQ(N2) = 0.11 ± 0.01 μs-1ppm-1, consistent with a previous measurement of this quantity but with significant improvement in precision. On the other hand, no evidence for absorption by N2 impurities has been found up to the higher concentrations here explored.

  1. Argon diffusion from biotite at high temperature and pressure

    Institute of Scientific and Technical Information of China (English)

    陈道公; 贾命命; 李彬贤; 陆全明; 谢鸿森; 侯渭

    1995-01-01

    t The experiments of argon diffusion dynamics for biotite were carried out at 700 -1000℃ and 0.5 - 2,0 GPa and the diffusion coefficient and activation energy using different models have been calculated. The results indicate that the pressure does affect the argon diffusion and its effect is opposite to that of temperature. When p increases, the activation energy increases and diffusion coefficient decreases. The relation between pressure, closure temperature and cooling rate has been obtained. It is postulated that in low T and high p conditions, the argon diffusion from the environment to the system could occur and incur the appearance of the external argon in minerals.

  2. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  3. Near-infrared scintillation of liquid argon

    CERN Document Server

    Alexander, T; Lippincott, W H; Rubinov, P

    2016-01-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  4. Argon isotope fractionation induced by stepwise heating

    Science.gov (United States)

    Trieloff, Mario; Falter, Martina; Buikin, Alexei I.; Korochantseva, Ekaterina V.; Jessberger, Elmar K.; Altherr, Rainer

    2005-03-01

    Noble gas isotopes are widely used to elucidate the history of the rocks in which they have been trapped, either from distinct reservoirs or by accumulation following radioactive decay. To extract noble gases from their host rocks, stepwise heating is the most commonly used technique to deconvolve isotopically different components, e.g., atmospheric, in situ radiogenic, or excess radiogenic from mantle or crustal reservoirs. The accurate determination of the isotopic composition of these different components is of crucial importance, e.g., for ages obtained by 40Ar- 39Ar stepheating plateaus. However, diffusion theory-based model calculations predict that the stepwise thermal extraction process from mineral phases induces isotope fractionation and, hence, adulterates the original composition. Such effects are largely unconsidered, as they are small and a compelling experimental observation is lacking. We report the first unequivocal evidence for significant mass fractionation of argon isotopes during thermal extraction, observed on shungite, a carbon-rich Precambrian sedimentary rock. The degree of fractionation, as monitored by 38Ar/ 36Ar and 40Ar/ 36Ar ratios, very well agrees with theoretical predictions assuming an inverse square root dependence of diffusion coefficient and atomic mass, resulting in easier extraction of lighter isotopes. Hence, subatmospheric 40Ar/ 36Ar ratios obtained for argon extracted at low temperatures may not represent paleoatmospheric argon. Shungite argon resembles modern atmospheric composition, but constraints on the timing of trapping appear difficult to obtain, as shungites are multicomponent systems. In 40Ar- 39Ar stepwise heating, the isotope fractionation effect could cause systematic underestimations of plateau ages, between 0.15 and 0.4% depending on age, or considerably higher if samples contain appreciable atmospheric Ar. The magnitude of this effect is similar to the presently achieved uncertainties of this increasingly

  5. Argon Purification Studies and a Novel Liquid Argon Re-circulation System

    CERN Document Server

    Mavrokoridis, K; Coleman, J; Lightfoot, P K; McCauley, N; McCormick, K J; Touramanis, C

    2011-01-01

    Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purification chemicals, as well as the Liverpool LAr setup, which utilises a novel re-circulation purification system. Of the impurities tested - Air, O_2, H_2O, N_2 and CO_2 in the range of between 0.01 ppm to 1000 ppm - H_2O was found to have the most profound effect on gaseous argon scintillation light, and N_2 was found to have the least. Additionally, a correlation between the slow component decay time and the total energy deposited with 0.01 ppm - 100 ppm O_2 contamination levels in liquid argon has been established. The superiority of molecular sieves over anhydrous complexes at absorbing Ar gas, N_2 gas and H_2O vapou...

  6. Ion-beam excitation of liquid argon

    CERN Document Server

    Hofmann, M; Heindl, T; Neumeier, A; Oberauer, L; Potzel, W; Roth, S; Schönert, S; Wieser, J; Ulrich, A

    2015-01-01

    The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions, were used to excite liquid argon. Only minor differences were observed in the wavelength-spectra obtained with the different incident particles. Light emission in the wavelength range of the third excimer continuum was found to be strongly suppressed in the liquid phase. In time-resolved measurements, the time structure of the scintillation light can be directly attributed to wavelength in our studies, as no wavelength shifter has been used. These measurements confirm that the singlet-to-triplet intensity ratio in the second excimer continuum range is a useful parameter for particle discrimination, which can also be employed in wavelength-integrated measurements as long as the sensitivity of the detector system does not rise steeply for wavelengths longer than 190 nm. Using ou...

  7. Argon laser-welded arteriovenous anastomoses.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; White, G; Lyons, R; Fujitani, R; Klein, S R; Uitto, J

    1987-11-01

    This study compared the healing of laser-welded and sutured canine femoral arteriovenous anastomoses. Arteriovenous fistulas 2 cm in length were created bilaterally in the femoral vessels of 10 dogs and were studied at 1 (n = 2), 2 (n = 2), 4 (n = 3), and 8 (n = 3) weeks. In each animal, one anastomosis (control) was closed with running 6-0 polypropylene sutures, and the contralateral anastomosis (experimental) was sealed with an argon laser (0.5 watt, 4 minutes of exposure, 1830 J/cm2/1 cm length of anastomosis). At removal all experimental anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 4 weeks revealed that laser-welded anastomoses had less inflammatory response and almost normal collagen and elastin reorientation. At 8 weeks sutured anastomoses had significant intimal hyperplasia whereas laser repairs had normal luminal architecture. Tensile strength and collagen production, measured by the synthesis of hydroxyproline and the steady-state levels of type I and type III procollagen messenger ribonucleic acids, at the anastomoses and in adjacent vein and artery specimens were similar in sutured and laser-welded repairs at 2, 4, and 8 weeks. We conclude that argon laser welding of anastomoses is an acceptable alternative to suture techniques, with the advantage of improved healing without foreign body response and possible diminished intimal hyperplasia at the anastomotic line. PMID:3312648

  8. Electron scattering and transport in liquid argon

    International Nuclear Information System (INIS)

    The transport of excess electrons in liquid argon driven out of equilibrium by an applied electric field is revisited using a multi-term solution of Boltzmann’s equation together with ab initio liquid phase cross-sections calculated using the Dirac-Fock scattering equations. The calculation of liquid phase cross-sections extends previous treatments to consider multipole polarisabilities and a non-local treatment of exchange, while the accuracy of the electron-argon potential is validated through comparison of the calculated gas phase cross-sections with experiment. The results presented highlight the inadequacy of local treatments of exchange that are commonly used in liquid and cluster phase cross-section calculations. The multi-term Boltzmann equation framework accounting for coherent scattering enables the inclusion of the full anisotropy in the differential cross-section arising from the interaction and the structure factor, without an a priori assumption of quasi-isotropy in the velocity distribution function. The model, which contains no free parameters and accounts for both coherent scattering and liquid phase screening effects, was found to reproduce well the experimental drift velocities and characteristic energies

  9. Pollution of liquid argon after neutron irradiation

    CERN Document Server

    Andrieux, M L; Collot, J; de Saintignon, P; Ferrari, A; Hostachy, J Y; Hoummada, A; Martin, P; Merkel, B; Puzo, P; Sauvage, D; Wielers, M

    2001-01-01

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem. (17 refs).

  10. Pollution of liquid argon after neutron irradiation

    International Nuclear Information System (INIS)

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem

  11. WARP: a double phase argon programme for dark matter detection

    International Nuclear Information System (INIS)

    WARP (Wimp ARgon Programme) is a double phase Argon detector for Dark Matter search under construction at Laboratori Nazionali del Gran Sasso. We present recent results obtained operating a prototype with a sensitive mass of 2.3 litres deep underground

  12. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.;

    1981-01-01

    By means of the Rutherford-backscattering method, the stopping cross section of solid argon has been measured for 0.5–3 MeV helium ions to an accuracy of not, vert, similar3%. The results agree within the experimental accuracies with our earlier measurements for gaseous argon over the energy region...

  13. Nitrogen Removal from Molten Steel under Argon DC Glow Plasma

    Institute of Scientific and Technical Information of China (English)

    SUN Ming-shan; DING Wei-zhong; LU Xiong-gang

    2005-01-01

    Under argon DC glow plasma, the nitrogen removal from molten steel was studied. The experimental result showed that nitrogen mass percent could be reduced to 0.000 8%. The change of polarity had no impact on nitrogen removal when the nitrogen mass percent was low. The mechanism of denitrogenation of molten steel under argon DC glow plasma was discussed.

  14. Comparison of Diode and Argon Laser Lesions in Rabbit Retina

    Institute of Scientific and Technical Information of China (English)

    Hui Zhang; Xiaoxin Li; Bin Li; Jiping Da

    2004-01-01

    Purpose: To compare the histological alteration of retina with various spot intensities between diode and argon lasers in order to instruct the clinical use of 810 nm diode laser.Methods: Transpupillary retinal photocoagulations were performed on 42 eyes of 27pigmented rabbits. Histopathologic alteration of lesions in different intensities and different time intervals after irradiation produced by diode and argon laser was observed and compared using light microscopy. Areas of various lesions measured by image analysis system (CMIAS) were compared quantitatively.Results: Histopathologically, two-week-old grade 2 lesions produced by diode laser induced the disappearance of outer nuclear cells. More than a half of all showed reduction in number of outer nuclear layer cells in argon. Fibroblasts appeared in the diode grade 3lesions 5 days after irradiation. CMIAS data showed that all the areas of diode lesions immediately after photocoagulation were to be larger than those of argon laser lesions in the same spot intensity (P < 0.05). However, twenty-four hours after photocoagulation, the area of the diode lesions increased less than that of the argon laser lesions (8%vs.23%).Conclusion: The acute histological effect caused by 810 nm diode laser and argon green laser is similar,while the expansion of lesion area 24 hours after photocoagulation was less with the diode laser compared to the argon. This may be the first report in the literature regarding quantitative analysis of the delayed reaction of argon green lasers.

  15. Merging of high speed argon plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Case, A.; Messer, S.; Brockington, S.; Wu, L.; Witherspoon, F. D. [HyperV Technologies Corp., Chantilly, Virginia 22180 (United States); Elton, R. [University of Maryland, College Park, Maryland 20742 (United States)

    2013-01-15

    Formation of an imploding plasma liner for the plasma liner experiment (PLX) requires individual plasma jets to merge into a quasi-spherical shell of plasma converging on the origin. Understanding dynamics of the merging process requires knowledge of the plasma phenomena involved. We present results from the study of the merging of three plasma jets in three dimensional geometry. The experiments were performed using HyperV Technologies Corp. 1 cm Minirailguns with a preionized argon plasma armature. The vacuum chamber partially reproduces the port geometry of the PLX chamber. Diagnostics include fast imaging, spectroscopy, interferometry, fast pressure probes, B-dot probes, and high speed spatially resolved photodiodes, permitting measurements of plasma density, temperature, velocity, stagnation pressure, magnetic field, and density gradients. These experimental results are compared with simulation results from the LSP 3D hybrid PIC code.

  16. Large vessel sealing with the argon laser.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; Lyons, R; White, G; Klein, S R; Pizzurro, D; Abergel, R P; Dwyer, R M; Uitto, J

    1987-01-01

    This study compared the histology, biochemistry, and tensile strength of laser-welded and sutured canine venotomies, arteriotomies, and arteriovenous fistulas. Twelve animals had bilateral femoral vessels studied, with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralateral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks (four animals for each type of repair), and were evaluated histologically by hematoxylin and eosin, elastin, and trichrome stains; biochemically by the formation of [3H]hydroxyproline as an index of collagen synthesis; and mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms, or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welding may be an alternative to sutures for repair of large-diameter venotomies, arteriotomies, and arteriovenous fistulas, as healing is comparable to that seen with suture repairs up to 4 weeks postoperatively. PMID:3306233

  17. Vascular Welding Using The Argon Laser

    Science.gov (United States)

    White, Rodney A.; Donayre, Carlos; Kopchok, George; White, Geoffrey; Abergel, R. Patrick; Lyons, Richard; Klein, Stanley; Dwyer, Richard; Uitto, Jouni

    1987-03-01

    This study compared the histology, biochemistry, and tensile strength of laser welded and sutured canine venotomies, arteriotomies and arteriovenous fistulas. Bilateral femoral, carotid or jugular vessels were studied with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralatral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks for each type of repair and evaluated histologically by hematoxylineosin, elastin and trichrome stains, biochemically by the formation of [3H] hyaroxyproline as an index of collagen synthesis, ana mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welaing may be an alternative to sutures for repair of large diameter venotomies, arteriotomies and arteriovenous fistulas, as they heal comparable to suture repairs up to 4 weeks postoperatively.

  18. Commissioning of the ATLAS liquid argon calorimeters

    CERN Document Server

    Rezaie, Erfan

    ATLAS, a multi-purpose detector built at the LHC at CERN, requires an extensive commissioning campaign to be ready for proton-proton collisions. In this work, we focus on the commissioning of the liquid Argon (LAr) calorimeters, with emphasis on commissioning with cosmic rays. First we outline one phase of the commissioning work, which involves testing of the front-end electronics of the two endcap calorimeters. We then describe two cosmic ray generators as input to a Monte-Carlo simulation of cosmic rays in ATLAS, and compare their results. Finally, we explain a technique developed for this work which uses information from the Tile calorimeters to predict the timing of cosmic rays within the LAr calorimeters, because cosmic rays occur randomly in time whereas the electronics are clocked at [Special characters omitted.] . The results from this analysis tool are compared to default tools, using both simulated and real cosmic ray data in the calorimeters.

  19. Argon laser induced changes to the carbonate content of enamel

    International Nuclear Information System (INIS)

    Argon laser irradiation can be used to cure orthodontic brackets onto teeth in significantly less time than conventional curing lights. In addition, it has been shown that the argon laser seems to impart a demineralization resistance to the enamel. The purpose of this study was to use surface science techniques to ascertain if this demineralization resistance is possibly a result of a decrease in the carbonate content of enamel. Eleven mandibular third molars previously scheduled for extraction were collected and used in the present study. The teeth were sectioned in two and randomly assigned to either the argon laser (457-502 nm; 250 mW cm-2) or the control (no treatment) group. The sections assigned to the argon laser group were cured for 10 s and analyzed. To exaggerate any potential changes the experimental sections were then exposed to a further 110 s of argon laser irradiation. Surface analysis was performed using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results showed no statistically significant change in the carbonate content of enamel after argon laser irradiation (p > 0.05). Thus, it is suggested that any demineralization resistance imparted to the enamel surface by argon laser irradiation is not due to alterations in carbonate content.

  20. LArGe - A liquid argon scintillation veto for GERDA

    OpenAIRE

    Heisel, M.(Max-Planck-Institut für Kernphysik, Heidelberg, Germany)

    2011-01-01

    LArGe is a Gerda low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the Gerda experiment. Gerda searches for the neutrinoless double-beta decay in 76Ge, by operating naked germanium detectors submersed into 65 m3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used...

  1. Practical reactor production of {sup 41}Ar from argon clathrate

    Energy Technology Data Exchange (ETDEWEB)

    Mercer, J.R. E-mail: jmercer@pharmacy.ualberta.ca; Duke, M.J.M.; McQuarrie, S.A

    2000-06-01

    The radionuclide {sup 41}Ar has many ideal properties as a gas flow tracer. However, the modest cross-section of {sup 40}Ar for thermal neutron activation makes preparation of suitable activities of {sup 41}Ar technically difficult particularly for low flux reactors. Argon can however be trapped in a molecular complex called a clathrate that can then be irradiated. We prepared argon clathrate and explored its irradiation and stability characteristics. Argon clathrate can be used to provide gigabecquerel quantities of {sup 41}Ar even with low power reactors.

  2. The Effects of Dissolved Methane upon Liquid Argon Scintillation Light

    CERN Document Server

    Jones, B J P; Back, H O; Collin, G; Conrad, J M; Greene, A; Katori, T; Pordes, S; Toups, M

    2013-01-01

    In this paper we report on measurements of the effects of dissolved methane upon argon scintillation light. We monitor the light yield from an alpha source held 20 cm from a cryogenic photomultiplier tube (PMT) assembly as methane is injected into a high-purity liquid argon volume. We observe significant suppression of the scintillation light yield by dissolved methane at the 10 part per billion (ppb) level. By examining the late scintillation light time constant, we determine that this loss is caused by an absorption process and also see some evidence of methane-induced scintillation quenching at higher concentrations (50-100 ppb). Using a second PMT assembly we look for visible re-emission features from the dissolved methane which have been reported in gas-phase argon methane mixtures, and we find no evidence of visible re-emission from liquid-phase argon methane mixtures at concentrations between 10 ppb and 0.1%.

  3. Evidence of electric breakdown induced by bubbles in liquid argon

    CERN Document Server

    Bay, F; Murphy, S; Resnati, F; Rubbia, A; Sergiampietri, F; Wu, S

    2014-01-01

    We report on the results of a high voltage test in liquid argon in order to measure its dielectric rigidity. Under stable conditions and below the boiling point, liquid argon was found to sustain a uniform electric field of 100 kV/cm, applied in a region of 20 cm$^2$ area across 1 cm thick gap. When the liquid is boiling, breakdowns may occur at electric fields as low as 40 kV/cm. This test is one of the R&D efforts towards the Giant Liquid Argon Charge Imaging ExpeRiment (GLACIER) as proposed Liquid Argon Time Projection Chamber (LAr TPC) for the LBNO observatory for neutrino physics, astrophysics and nucleon decay searches.

  4. A purity monitoring system for liquid argon calorimeters

    International Nuclear Information System (INIS)

    For liquid argon calorimeters electronegative impurities dissolved in the medium degrade the detector response and deteriorate the energy resolution, especially at high energies. A concept for a purity monitoring system for liquid argon calorimeters has been developed and is presented here. Special combined monitors of 241Am- and 207Bi-cells are used to monitor the concentration of impurities. The working principle as well as results from test measurements are discussed

  5. Size Determination of Argon Clusters from a Rayleigh Scattering Experiment

    Institute of Scientific and Technical Information of China (English)

    LEI An-Le; ZHAI Hua-Jin; LIU Bing-Chen; LI Zhong; NI Guo-Yuan; XU Zhi-Zhan

    2000-01-01

    Argon clusters are produced in the process of adiabatic expansion of a high backing pressure gas into vacuum through a nozzle. The cluster size is determined by a Rayleigh scattering measurement. The scattered signal measured is proportional to the 2.78th power of gas stagnation pressure. The average cluster sizes vary from 100 to more than 12000 atoms/cluster with the argon gas backing pressures ranging between 3 to 45 atm.

  6. Pulse shape discrimination studies in a liquid Argon scintillation detector

    OpenAIRE

    Pollmann, T.

    2007-01-01

    Liquid rare gases have been gaining popularity as detector media in rare event searches, especially dark matter experiments, and one factor driving their adoption is the possibility to recognise different types of ionizing radiation by the pulse shapes they evoke. This work on pulse shape discrimination in a liquid argon scintillation detector was done in the framework of the GERDA experiment, where liquid argon scintillation signals may be used for background suppression purposes. Liquid arg...

  7. Power Consideration for Pulsed Discharges in Potassium Seeded Argon

    Institute of Scientific and Technical Information of China (English)

    XIA Sheng-Guo; HE Jun-Jia; LIU Ke-Fu

    2007-01-01

    Minimization of energy consumed in plasma generation is critical for applications, in which a large volume of plasmas is needed. We suggest that a high electron density atmospheric pressure plasmas can be generated by pulsed discharges in potassium seeded argon at an elevated temperature with a very small power input. The ionization efficiency and power budget of pulsed discharges in such plasmas are analytically studied. The results show that ionization efficiency of argon, especially at small reduced electric field E/N (the ratio of the electric field to the gas number density), is improved effectively in the presence of small amount of potassium additives. Power input of pulsed discharge to sustain a prescribed average level of ionization in potassium seeded argon is three orders of magnitude lower than that in pure argon. Further, unlike in pure argon, it is found that very short high-voltage pulses with very high repetition rates are unnecessary in potassium seeded argon. A pulse with 100ns of pulse duration, 5kHz of repetition rate, and 2Td (1 Td = 1 ×10-21 Vm2) of E/N is enough to sustain an electron density of 10l9m-3 in 1 atm 1500 K Ar+0.1% K mixture, with a very small power input of about 0.08 × 104 W/m3.

  8. Energy resolution for α-particles in doped liquid argon

    International Nuclear Information System (INIS)

    The report describes experiments on the effect of allene doped in liquid argon. In the case of doped argon, a large amount of charge is obtained even at low electric fields and the measured charge increases with the field gradually. This can be explained as follows; part of deposited energy which does not form charge in pure argon contributes to charge signal in doped argon through scintillation photons which ionize allene molecules. The main factors determining the energy resolution for α-particles are considered to be (1) fluctuation in the number of produced ion-electron pairs as expressed by the Fano factor, (2) fluctuation in recombination process, (3) fluctuation in photoionization, (4) fluctuation due to the condition of radioactive source and surface of electrodes, (5) fluctuation in geometrical efficiency due to the range and emission angle of α-particles in liquid argon, and (6) electronic noise of amplifier. The factors (1) and (3) can be neglected because of a large number of associated electrons or photons. In pure liquid argon, the factor (2) may be a cause of bad resolution since the fraction of the produced ion-electron paris which do not recombine is small and the photoionization process never occurs for photons emitted through recombination. (N.K.)

  9. New argon-argon (40Ar/39Ar) radiometric age dates from selected subsurface basalt flows at the Idaho National Laboratory, Idaho

    Science.gov (United States)

    Hodges, Mary K.; Turrin, Brent D.; Champion, Duane E.; Swisher, Carl C.

    2015-01-01

    In 2011, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collected samples for 12 new argon-argon radiometric ages from eastern Snake River Plain olivine tholeiite basalt flows in the subsurface at the Idaho National Laboratory. The core samples were collected from flows that had previously published paleomagnetic data. Samples were sent to Rutgers University for argon-argon radiometric dating analyses.

  10. Evolution of Martian atmospheric argon: Implications for sources of volatiles

    Science.gov (United States)

    Hutchins, Kevin S.; Jakosky, Bruce M.

    We have examined processes affecting isotopes of argon (36Ar, 38Ar, 40Ar) in order to determine important atmospheric sources and sinks. Our simple model for argon evolution incorporates production of radiogenic argon in the mantle, outgassing of all argon species by extrusive and intrusive volcanism, and loss to space by knock-on sputtering above the exobase. Sputtering has been shown previously to be an important loss process for atmospheric species, especially isotopes of noble gases, which have few other mechanisms of escape. The integrated evolution of argon (36Ar, 38Ar, and 40Ar, respectively) is modeled in terms of these variables: (1) the planetary concentration of potassium, (2) the fraction of juvenile argon released catastrophically during the first 600 Myr., (3) potential variation in the time-history of sputtering loss from that suggested by Luhmann et al. [1992], and (4) the volume of total outgassing to the surface as compared to outgassing contributed by volcanic release. Our results indicate that Mars has lost between 85-95% of 36Ar and 70-88% of outgassed 40Ar. Due to this substantial loss, the planet must have outgassed the equivalent of between 10 and 100 times the total volume of gases released by extrusive and intrusive volcanics. This indicates that volcanic outgassing, alone, is insufficient to explain the present-day abundances of 36Ar and 40Ar in the Martian atmosphere. Similar calculations for 20Ne suggest outgassed volumes of between 100 and 1800 times in excess of that due to volcanism. This results in a distinct Ne/Ar elemental fractionation, with a preference for outgassing argon, of the order of 10 to 17. Although the results must be evaluated within the model uncertainties, the results are compelling in that they unequivocally show the existence of additional sources of atmospheric volatiles and helps define a means to identify them.

  11. Characterisation of GERDA Phase-I detectors in liquid argon

    International Nuclear Information System (INIS)

    GERDA will search for neutrinoless double beta decay in 76Ge by submerging bare enriched HPGe detectors in liquid argon. In GERDA Phase-I, reprocessed enriched-Ge detectors, which were previously operated by the Heidelberg-Moscow and IGEX collaborations, and reprocessed natural-Ge detectors from Genius-TF, will be redeployed. We have tested the operation and performance of bare HPGe detectors in liquid nitrogen and in liquid argon over more than three years with three non-enriched p-type prototype detectors. The detector handling and mounting procedures have been defined and the Phase-I detector technology, the low-mass assembly and the long-term stability in liquid argon have been tested successfully. The Phase-I detectors were reprocessed by Canberra Semiconductor NV, Olen, according to their standard technology but without the evaporation of a passivation layer. After their reprocessing, the detectors have been mounted in their low-mass holders and their characterisation in liquid argon performed. The leakage current, the counting characteristics and the efficiency of the detectors have been measured. The testing of the detectors was carried out in the liquid argon test stand of the GERDA underground Detector Laboratory (GDL) at LNGS. The detectors are now stored underground under vacuum until their operation in GERDA.

  12. The Spectroscopic Detectability of Argon in the Lunar Atmosphere

    CERN Document Server

    Parker, J W; Gladstone, G R; Shull, J M; Parker, Joel Wm.

    1999-01-01

    Direct measurements of the abundance of argon in the lunar atmosphere were made in 1973 by instruments placed on the Moon during the Apollo 17 mission, but the total daytime abundance is unknown due to instrument saturation effects; thus, until we are able to return to the Moon for improved direct measurements, we must use remote sensing to establish the daytime abundance. In this paper, we present a complete analysis of the potential for measuring argon in the lunar atmosphere via emission-line or absorption-line observations. We come to the surprising conclusion that the lower limit established by the in situ lunar argon measurements implies that any absorption-line measurement of argon in the lower, dayside lunar atmosphere requires analysis in the optically-thick regime. In light of this result, we present the results of our EUVS sounding rocket observations of the lunar occultation of Spica, which provide a new upper limit on the abundance of argon in the daytime lunar atmosphere. We also re-analyze a re...

  13. Metastable argon beam source using a surface wave sustained plasma

    International Nuclear Information System (INIS)

    A new source of metastable argon atoms in the thermal energy range is reported. The source is based on expanding a plasma sustained by electromagnetic surface waves in a quartz tube through a converging nozzle and extracting a beam from the supersonic free-expansion jet. The beam was characterized by time-of-flight measurements which yielded the absolute intensity and velocity distribution of the argon metastables. The source produced a maximum intensity of 6.2x1014 metastables per second per steradian, the highest time-averaged intensity of thermal argon metastables of any source reported to date. A simple picture of an expanding plasma in a recombination regime is used to explain the dependence of the metastable intensity on absorbed power

  14. On the electric breakdown in liquid argon at centimeter scale

    Science.gov (United States)

    Auger, M.; Blatter, A.; Ereditato, A.; Goeldi, D.; Janos, S.; Kreslo, I.; Luethi, M.; von Rohr, C. Rudolf; Strauss, T.; Weber, M. S.

    2016-03-01

    We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  15. The Simulation of the ATLAS Liquid Argon Calorimetry

    CERN Document Server

    Archambault, J P; Carli, T; Costanzo, D; Dell'Acqua, A; Djama, F; Gallas, M; Fincke-Keeler, M; Khakzad, M; Kiryunin, A; Krieger, P; Leltchouk, M; Loch, P; Ma, H; Menke, S; Monnier, E; Nairz, A; Niess, V; Oakham, G; Oram, C; Pospelov, G; Rajagopalan, S; Rimoldi, A; Rousseau, D; Rutherfoord, J; Seligman, W; Soukharev, A; Strízenec, P; Tóth, J; Tsukerman, I; Tsulaia, V; Unal, G; Grahn, K J

    2008-01-01

    In ATLAS, all of the electromagnetic calorimetry and part of the hadronic calorimetry is performed by a calorimeter system using liquid argon as the active material, together with various types of absorbers. The liquid argon calorimeter consists of four subsystems: the electromagnetic barrel and endcap accordion calorimeters; the hadronic endcap calorimeters, and the forward calorimeters. A very accurate geometrical description of these calorimeters is used as input to the Geant 4-based ATLAS simulation, and a careful modelling of the signal development is applied in the generation of hits. Certain types of Monte Carlo truth information ("Calibration Hits") may, additionally, be recorded for calorimeter cells as well as for dead material. This note is a comprehensive reference describing the simulation of the four liquid argon calorimeteter components.

  16. Energy resolution studies of liquid argon ionization detectors

    International Nuclear Information System (INIS)

    A gridded ionization chamber was used to study the energy resolution in liquid argon with electrons from a 207Bi radioactive source. Argon was purified in the gas phase with a simple and reliable system, capable of reducing the impurity level below 1 ppb O2 equivalent, as inferred by a pulse shape analysis of the ionization signals. The electron spectrum was measured at different drift fields, up to 10.9 KV/cm. At this maximum field, a total energy resolution of 32 keV (fwhm), corresponding to a noise-subtracted energy resolution of 26 keV (fwhm), was obtained for the 976 keV conversion electron line. This value is the best reported so far in liquid argon but is still a factor of seven worse than the theoretical limit set by the Fano factor. The reasons for this discrepancy are discussed. (orig.)

  17. Liquid Argon Calorimetry with LHC-Performance Specifications

    CERN Multimedia

    2002-01-01

    % RD-3 Liquid Argon Calorimetry with LHC-Performance Specifications \\\\ \\\\Good electromagnetic and hadronic calorimetry will play a central role in an LHC detector. Among the techniques used so far, or under development, the liquid argon sampling calorimetry offers high radiation resistence, good energy resolution (electromagnetic and hadronic), excellent calibration stability and response uniformity. Its rate capabilities, however, do not yet match the requirements for LHC. \\\\ \\\\The aim of this proposal is to improve the technique in such a way that high granularity, good hermiticity and adequate rate capabilities are obtained, without compromising the above mentioned properties. To reach this goal, we propose to use a novel structure, the $^{\\prime\\prime}$accordion$^{\\prime\\prime}$, coupled to fast preamplifiers working at liquid argon temperature. Converter and readout electrodes are no longer planar and perpendicular to particles, as usual, but instead they are wiggled around a plane containing particles. ...

  18. A therapeutic experience on Port Wine hemangiomas with Argon Laser

    Directory of Open Access Journals (Sweden)

    Farahvash M

    1997-09-01

    Full Text Available Port wine stains are benign but cosmetically devasting congenital angiomas. The argon laser is a therapeutic device newly applied to this condition. Our program was begun 6 years ago. From the beginning, the study was conceived as a clinical investigation of both the port wine stain and its argon laser therapy. A total of 218 patients with port wine stains have been studied and many aspects of their clinical condition detailed. Employing the Argon laser, test spots have been carried out in patients and the results have been analyzed with clinical aspects of the lesions. Altogether, 501 treatments were performed in 218 patients. Good to excellent results were obtained in 81 patients. Moderate Result was obtained in 31 weak result in 65 patients. Most common complication were hyperpigmentation and depressed scar.

  19. On the Electric Breakdown in Liquid Argon at Centimeter Scale

    CERN Document Server

    Auger, M; Ereditato, A; Goeldi, D; Janos, S; Kreslo, I; Luethi, M; von Rohr, C Rudolf; Strauss, T; Weber, M S

    2015-01-01

    We present a study on the dependence of electric breakdown discharge parameters on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  20. Vaporization kinetics of Sb2S3 in argon fluid

    Institute of Scientific and Technical Information of China (English)

    杨勇; 华一新

    2003-01-01

    The vaporization kinetics of antimony trisulfide in argon fluid was studied with thermogravimetry at 873- 1 173 K. A theoretical model was developed to calculate the overall rate constant and the mass transfer coefficient ingas phase. The experimental results show that the vaporization rate is enhanced with increasing temperature and ar-gon flow-rate. The evaporation rate is mainly controlled by mass transport in the gas phase. The apparent activationenergy for the process is found to be 55.54 kJ/mol. It is demonstrated that the mass transfer coefficient in gas phaseis decreased with increasing temperature.

  1. Modelling of a supersonic ICP argon-hydrogen expansion

    International Nuclear Information System (INIS)

    An expanding argon-hydrogen plasma is investigated by means of simulations. The model is a hydrodynamical model specific for plasma expansions, taking into account the conservation laws of mass, momentum and energy. The code includes the Rankine-Hugoniot relations to calculate shock jump conditions. Results are shown for the expansion from an inductively coupled plasma (ICP) with a separated Laval nozzle. The expansion discussed here is a 'weakly' under-expanding argon-hydrogen plasma. The results from the ICP expansion are verified with probe measurements

  2. Attosecond-correlated dynamics of two electrons in argon

    Indian Academy of Sciences (India)

    V Sharma; N Camus; B Fischer; M Kremer; A Rudenko; B Bergues; M Kuebel; N G Johnson; M F Kling; T Pfeifer; J Ullrich; R Moshammer

    2014-01-01

    In this work we explored strong field-induced decay of doubly excited transient Coulomb complex Ar** → Ar2++2. We measured the correlated two-electron emission as a function of carrier envelop phase (CEP) of 6 fs pulses in the non-sequential double ionization (NSDI) of argon. Classical model calculations suggest that the intermediate doubly excited Coulomb complex loses memory of its formation dynamics. We estimated the ionization time difference between the two electrons from NSDI of argon and it is 200 ± 100 as (N Camus et al, Phys. Rev. Lett. 108, 073003 (2012)).

  3. Uranium-liquid argon calorimetry: preliminary results from the DO tests

    International Nuclear Information System (INIS)

    The motivations for using uranium and liquid argon in sampling calorimetry are reviewed and the pros and cons of the technique are discussed. Preliminary results of the DO uranium-liquid argon test program are presented. 9 refs., 7 figs

  4. Optical emission spectroscopy of argon and hydrogen-containing plasmas

    Science.gov (United States)

    Siepa, Sarah; Danko, Stephan; Tsankov, Tsanko V.; Mussenbrock, Thomas; Czarnetzki, Uwe

    2015-09-01

    Optical emission spectroscopy (OES) on neutral argon is applied to investigate argon, hydrogen and hydrogen-silane plasmas. The spectra are analyzed using an extensive collisional-radiative model (CRM), from which the electron density and the electron temperature (or mean energy) can be calculated. The CRM also yields insight into the importance of different excited species and kinetic processes. The OES measurements are performed on pure argon plasmas at intermediate pressure. Besides, hydrogen and hydrogen-silane plasmas are investigated using argon as a trace gas. Especially for the gas mixture discharges, CRMs for low and high pressure differ substantially. The commonly used line-ratio technique is found to lose its sensitivity for gas mixture discharges at higher pressure. A solution using absolutely calibrated line intensities is proposed. The effect of radiation trapping and the shape of the electron energy distribution function on the results are discussed in detail, as they have been found to significantly influence the results. This work was supported by the Ruhr University Research School PLUS, funded by Germany's Excellence Initiative [DFG GSC 98/3].

  5. Measurement of the argon plasma temperature by use of pyrometer

    International Nuclear Information System (INIS)

    The author describes in detail how to use pyrometer to measure the plasma temperature. The temperatures of shock-generated argon plasmas are given in the present work. Measured results of temperature-pressure curve are compared with calculated results using Saha-Debye-Huckel model, which are in good agreement

  6. Turbulence and transport in a magnetized argon plasma

    International Nuclear Information System (INIS)

    An experimental study on turbulence and transport in the highly ionized argon plasma of a hollow cathode discharge is described. In order to determine the plasma parameters three standard diagnostics have been used, whilst two diagnostics have been developed to study the plasma turbulence. (Auth.)

  7. Thermophysical properties of multi-shock compressed dense argon.

    Science.gov (United States)

    Chen, Q F; Zheng, J; Gu, Y J; Chen, Y L; Cai, L C; Shen, Z J

    2014-02-21

    In contrast to the single shock compression state that can be obtained directly via experimental measurements, the multi-shock compression states, however, have to be calculated with the aid of theoretical models. In order to determine experimentally the multiple shock states, a diagnostic approach with the Doppler pins system (DPS) and the pyrometer was used to probe multiple shocks in dense argon plasmas. Plasma was generated by a shock reverberation technique. The shock was produced using the flyer plate impact accelerated up to ∼6.1 km/s by a two-stage light gas gun and introduced into the plenum argon gas sample, which was pre-compressed from the environmental pressure to about 20 MPa. The time-resolved optical radiation histories were determined using a multi-wavelength channel optical transience radiance pyrometer. Simultaneously, the particle velocity profiles of the LiF window was measured with multi-DPS. The states of multi-shock compression argon plasma were determined from the measured shock velocities combining the particle velocity profiles. We performed the experiments on dense argon plasmas to determine the principal Hugonoit up to 21 GPa, the re-shock pressure up to 73 GPa, and the maximum measure pressure of the fourth shock up to 158 GPa. The results are used to validate the existing self-consistent variational theory model in the partial ionization region and create new theoretical models. PMID:24559345

  8. Thermal decomposition of Yttrium(III) isovalerate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Tang, Xiao;

    2016-01-01

    The thermal behaviour of yttrium(III) isovalerate (Y(C4H9CO2)3) was studied in argon by means of thermogravimetry, differential thermal analysis, FTIR-spectroscopy, hot-stage optical microscopy and X-ray diffraction with a laboratory Cu-tube source as well as with a synchrotron radiation source...

  9. Thermal decomposition of yttrium(III) valerate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Tang, Xiao;

    2014-01-01

    The thermal decomposition of yttrium(III) valerate (Y(C4H9CO2)3) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction, in-situ synchrotron diffraction and hot-stage microscopy as well as room temperature optical microscopy. Melting...

  10. Thermal decomposition of yttrium(III) hexanoate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Suarez Guevara, Maria Josefina; Attique, Fahmida;

    2015-01-01

    The thermal decomposition of yttrium(III) hexanoate (Y(C5H11CO2)3)·xH2O in argon was studied by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction at a laboratory Cu-tube source and in-situ experiments at a synchrotron radiation source as well as hot...

  11. A 2-Dimensional Fluid Model for an Argon Rf Discharge

    NARCIS (Netherlands)

    Passchier, J. D. P.; W. J. Goedheer,

    1993-01-01

    A fluid model for an argon rf discharge in a cylindrical discharge chamber is presented. The model contains the particle balances for electrons and ions and the electron energy balance. A nonzero autobias voltage is obtained by imposing the condition that the time-averaged current toward the powered

  12. Study of Liquid Argon Dopants for LHC Hadron Calorimetry

    CERN Multimedia

    2002-01-01

    Hadron calorimetry based on the Liquid Argon Ionisation Chamber technique is one of the choice techniques for LHC-experimentation. A systematic study of the effect of selected dopants on Liquid Argon (LAr) will be carried out with the aim to achieve an improvement on: \\item (i)~``Fast Liquid Argon'' search and study of dopants to increase the drift velocity. It has been already shown that CH&sub4. added at a fraction of one percent increases the drift velocity by a factor of two or more. \\item (ii)~``Compensated Liquid Argon'' search and study of dopants to increase the response to densely ionising particles, resulting in improved compensation, such as photosensitive dopants. \\end{enumerate}\\\\ \\\\ Monitoring of the parameters involved in understanding the response of a calorimeter is essential. In case of doped LAr, the charge yield, the non-saturated drift velocity and the electron lifetime in the liquid should be precisely and simultaneously monitored as they all vary with the level of dopant concentrati...

  13. LArGe. A liquid argon scintillation veto for GERDA

    International Nuclear Information System (INIS)

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in 76Ge, by operating naked germanium detectors submersed into 65 m3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 103 have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10-2 cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural 42Ar abundance (in parallel to Gerda), and have indication for the 2νββ-decay in natural germanium. (orig.)

  14. LArGe. A liquid argon scintillation veto for GERDA

    Energy Technology Data Exchange (ETDEWEB)

    Heisel, Mark

    2011-04-13

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in {sup 76}Ge, by operating naked germanium detectors submersed into 65 m{sup 3} of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m{sup 3} (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10{sup -2} cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural {sup 42}Ar abundance (in parallel to Gerda), and have indication for the 2{nu}{beta}{beta}-decay in natural germanium. (orig.)

  15. Design of capsules capable of argon-filling

    International Nuclear Information System (INIS)

    The possibility of the use of polycarbosilane capsules as fuel container in inertial confinement fusion experiments was analyzed in the paper. Primary study indicates that the polycarbosilane capsules can be filled with argon by means of diffusion and possess reasonable retention time for deuterium. (author)

  16. Conversion of an atomic to a molecular argon ion and low pressure argon relaxation

    Science.gov (United States)

    M, N. Stankov; A, P. Jovanović; V, Lj Marković; S, N. Stamenković

    2016-01-01

    The dominant process in relaxation of DC glow discharge between two plane parallel electrodes in argon at pressure 200 Pa is analyzed by measuring the breakdown time delay and by analytical and numerical models. By using the approximate analytical model it is found that the relaxation in a range from 20 to 60 ms in afterglow is dominated by ions, produced by atomic-to-molecular conversion of Ar+ ions in the first several milliseconds after the cessation of the discharge. This conversion is confirmed by the presence of double-Gaussian distribution for the formative time delay, as well as conversion maxima in a set of memory curves measured in different conditions. Finally, the numerical one-dimensional (1D) model for determining the number densities of dominant particles in stationary DC glow discharge and two-dimensional (2D) model for the relaxation are used to confirm the previous assumptions and to determine the corresponding collision and transport coefficients of dominant species and processes. Project supported by the Ministry of Education, Science and Technological Development of the Republic of Serbia (Grant No. ON171025).

  17. Observations of acoustic-wave-induced superluminescence in an argon plasma

    International Nuclear Information System (INIS)

    It is shown that in an argon discharge plasma it is possible to obtain overpopulation of certain electronic levels of atomic argon under the influence of acoustic waves. When the specified threshold is exceeded, then a superluminescence (in the form of light flashes) from the overpopulated electronic levels of atomic argon is observed

  18. 21 CFR 874.4490 - Argon laser for otology, rhinology, and laryngology.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Argon laser for otology, rhinology, and laryngology. 874.4490 Section 874.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Argon laser for otology, rhinology, and laryngology. (a) Identification. The argon laser device for...

  19. Argon metastable dynamics and lifetimes in a direct current microdischarge

    Science.gov (United States)

    Stefanović, Ilija; Kuschel, Thomas; Schröter, Sandra; Böke, Marc

    2014-09-01

    In this paper we study the properties of a pulsed dc microdischarge with the continuous flow of argon. Argon metastable lifetimes are measured by tunable diode laser absorption spectroscopy (TDLAS) and are compared with calculated values which yield information about excitation and de-excitation processes. By increasing the gas flow-rate about 5 times from 10 to 50 sccm, the Arm lifetime increases from 1 to 5 μs due to the reduction of metastable quenching with gas impurities. Optical emission spectroscopy reveals nitrogen and water molecules as the main gas impurities. The estimated N2 density [N2] = 0.1% is too low to explain the measured metastable lifetimes. Water impurity was found to be the main de-excitation source of argon metastable atoms due to high quenching coefficients. The water impurity level of [H2O] = 0.15% to 1% is sufficient to bring calculated metastable lifetimes in line with experiments. The maximum value of water content in the discharge compared to the argon atoms is estimated to approximately 6%, due to the large surface to volume ratio of the microdischarge. The current pulse releases the water molecules from the electrode surface and they are either re-adsorbed in the time between 0.4 ms for [H2O] = 1% and 2.6 ms for [H2O] = 0.15% or pumped out of the discharge with the speed equal to the gas flow-rate. Depending on its partial pressure, the water impurity re-adsorption time is of the order of magnitude or less then the argon gas residence time.

  20. EFFECTS OF ARGON ON THE PROPERTIES OF RF SPUTTERED AMORPHOUS SILICON

    OpenAIRE

    Shao-Qi, Peng; Qai, Yu; Xian, Zhang; Jing, Ye

    1981-01-01

    The Effects of argon on the properties of rf sputtered amorphous silicon film have been investigated. As the sputtering argon pressure is increased from 2 to 20 mTorr, the content of argon in the amorphous silicon film increases apparently (Argon/Silicon : from 10-2 to 5 x 10-2). The other properties measured as a function of argon pressure PAr show that as the PAr is increased, the photoconductivity, resistivity (300K), conductivity activation energy and optical gap increase also, while the ...

  1. Narrow spectral width laser diode for metastable argon atoms pumping

    Science.gov (United States)

    Gao, Jun; Li, Bin; Wang, Xinbing; Zuo, Duluo

    2016-03-01

    Diode laser pump source with narrow emitting spectrum for optically pumped metastable rare gas laser (OPRGL) of argon was achieved by employing a complex external cavity coupled with volume Bragg grating (VBG). A commercially available c-mount laser diode with rated power of 6 W was used and studied in both the free running mode and VBG external cavity. The maximum output power of 3.9 W with FWHM less than 25 pm and peak wavelength locked around 811.53 nm was obtained from the VBG external cavity laser diode. Precise control of VBG temperature enabled fine tuning of the emission wavelength over a range of 450 pm. Future researches on OPRGL of argon will benefit from it.

  2. Evaporation and condensation at a liquid surface. I. Argon

    Science.gov (United States)

    Yasuoka, Kenji; Matsumoto, Mitsuhiro; Kataoka, Yosuke

    1994-11-01

    Molecular dynamics computer simulations were carried out to investigate the dynamics of evaporation and condensation for argon at the temperature of 80 and 100 K. From the decrease of the survival probability of vapor molecules, the ratio of self reflection to collision is estimated to be 12%-15%, only weakly dependent on the temperature. This suggests that argon vapor molecules are in the condition of almost complete capture, and the condensation is considered to be a barrierless process. The total ratio of reflection which is evaluated with the flux correlation of condensation and evaporation is 20% at both temperature. The difference between these two ratios of reflection is ascribed to a phenomenon that vapor molecules colliding with the surface drive out other liquid molecules. This molecule exchange at the surface is as important as the self-reflection, and the conventional picture of condensation as a unimolecular chemical reaction is not appropriate.

  3. The Erosion of Frozen Argon by Swift Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Graversen, O.;

    1981-01-01

    The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore unequivo......The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore...... unequivocally associated with electronic processes generated by the bombarding particle. In the present energy region, it is found that Y scales approximately as the electronic stopping power squared, depends on the charge state of the incoming helium ions, and perhaps more important, is independent...

  4. Demonstration of a Lightguide Detector for Liquid Argon TPCs

    CERN Document Server

    Bugel, L; Ignarra, C; Jones, B J P; Katori, T; Smidt, T; Tanaka, H -K

    2011-01-01

    We report demonstration of light detection in liquid argon using an acrylic lightguide detector system. This opens the opportunity for development of an inexpensive, large-area light collection system for large liquid argon time projection chambers. The guides are constructed of acrylic, with TPB embedded in a surface coating with a matching index of refraction. We study the response to early scintillation light produced by a 5.3 MeV alpha. We measure coating responses from 7 to 8 PE on average, compared to an ideal expectation of 10 PE on average. We estimate the attenuation length of light along the lightguide bar to be greater than 0.5 m. The coating response and the attenuation length can be improved; we show, however, that these results are already sufficient for triggering in a large detector.

  5. Trimming a Metallic Biliary Stent Using an Argon Plasma Coagulator

    International Nuclear Information System (INIS)

    Background. Distal migration is one of the common complications after insertion of a covered metallic stent. Stent repositioning or removal is not always possible in every patient. Therefore, trimming using an argon plasma coagulator (APC) may be a good alternative method to solve this problem. Methods. Metallic stent trimming by APC was performed in 2 patients with biliary Wallstent migration and in another patient with esophageal Ultraflex stent migration. The power setting was 60-100 watts with an argon flow of 0.8 l/min. Observations. The procedure was successfully performed and all distal parts of the stents were removed. No significant collateral damage to the nearby mucosa was observed. Conclusions. In a patient with a distally migrated metallic stent, trimming of the stent is possible by means of an APC. This new method may be applicable to other sites of metallic stent migration

  6. Readiness of the ATLAS Liquid Argon Calorimeter for LHC Collisions

    CERN Document Server

    Aad, G; Abdallah, J; Abdelalim, A A; Abdesselam, A; Abdinov, O; Abi, B; Abolins, M; Abramowicz, H; Abreu, H; Acharya, B S; Adams, D L; Addy, T N; Adelman, J; Adorisio, C; Adragna, P; Adye, T; Aefsky, S; Aguilar-Saavedra, J A; Aharrouche, M; Ahlen, S P; Ahles, F; Ahmad, A; Ahmed, H; Ahsan, M; Aielli, G; Akdogan, T; Åkesson, T P A; Akimoto, G; Akimov, A V; Aktas, A; Alam, M S; Alam, M A; Albert, J; Albrand, S; Aleksa, M; Aleksandrov, I N; Alessandria, F; Alexa, C; Alexander, G; Alexandre, G; Alexopoulos, T; Alhroob, M; Aliev, M; Alimonti, G; Alison, J; Aliyev, M; Allport, P P; Allwood-Spiers, S E; Almond, J; Aloisio, A; Alon, R; Alonso, A; Alviggi, M G; Amako, K; Amelung, C; Ammosov, V V; Amorim, A; Amorós, G; Amram, N; Anastopoulos, C; Andeen, T; Anders, C F; Anderson, K J; Andreazza, A; Andrei, V; Anduaga, X S; Angerami, A; Anghinolfi, F; Anjos, N; Antonaki, A; Antonelli, M; Antonelli, S; Antunovic, B; Anulli, F; Aoun, S; Arabidze, G; Aracena, I; Arai, Y; Arce, A T H; Archambault, J P; Arfaoui, S; Arguin, J-F; Argyropoulos, T; Arik, E; Arik, M; Armbruster, A J; Arnaez, O; Arnault, C; Artamonov, A; Arutinov, D; Asai, M; Asai, S; Asfandiyarov, R; Ask, S; Åsman, B; Asner, D; Asquith, L; Assamagan, K; Astbury, A; Astvatsatourov, A; Atoian, G; Auerbach, B; Auge, E; Augsten, K; Aurousseau, M; Austin, N; Avolio, G; Avramidou, R; Axen, D; Ay, C; Azuelos, G; Azuma, Y; Baak, M A; Baccaglioni, G; Bacci, C; Bach, A; Bachacou, H; Bachas, K; Backes, M; Badescu, E; Bagnaia, P; Bai, Y; Bailey, D C; Bain, T; Baines, J T; Baker, O K; Baker, M D; Baltasar Dos Santos Pedrosa, F; Banas, E; Banerjee, P; Banerjee, S; Banfi, D; Bangert, A; Bansal, V; Baranov, S P; Baranov, S; Barashkou, A; Barber, T; Barberio, E L; Barberis, D; Barbero, M; Bardin, D Y; Barillari, T; Barisonzi, M; Barklow, T; Barlow, N; Barnett, B M; Barnett, R M; Baron, S; Baroncelli, A; Barr, A J; Barreiro, F; BarreiroGuimarães da Costa, J; Barrillon, P; Barros, N; Bartoldus, R; Bartsch, D; Bastos, J; Bates, R L; Bathe, S; Batkova, L; Batley, J R; Battaglia, A; Battistin, M; Bauer, F; Bawa, H S; Bazalova, M; Beare, B; Beau, T; Beauchemin, P H; Beccherle, R; Becerici, N; Bechtle, P; Beck, G A; Beck, H P; Beckingham, M; Becks, K H; Bedajanek, I; Beddall, A J; Beddall, A; Bednár, P; Bednyakov, V A; Bee, C; Begel, M; Behar Harpaz, S; Behera, P K; Beimforde, M; Belanger-Champagne, C; Bell, P J; Bell, W H; Bella, G; Bellagamba, L; Bellina, F; Bellomo, M; Belloni, A; Belotskiy, K; Beltramello, O; Ben Ami, S; Benary, O; Benchekroun, D; Bendel, M; Benedict, B H; Benekos, N; Benhammou, Y; Benincasa, G P; Benjamin, D P; Benoit, M; Bensinger, J R; Benslama, K; Bentvelsen, S; Beretta, M; Berge, D; Bergeaas Kuutmann, E; Berger, N; Berghaus, F; Berglund, E; Beringer, J; Bernardet, K; Bernat, P; Bernhard, R; Bernius, C; Berry, T; Bertin, A; Besson, N; Bethke, S; Bianchi, R M; Bianco, M; Biebel, O; Biesiada, J; Biglietti, M; Bilokon, H; Bindi, M; Binet, S; Bingul, A; Bini, C; Biscarat, C; Bitenc, U; Black, K M; Blair, R E; Blanchard, J-B; Blanchot, G; Blocker, C; Blocki, J; Blondel, A; Blum, W; Blumenschein, U; Bobbink, G J; Bocci, A; Boehler, M; Boek, J; Boelaert, N; Böser, S; Bogaerts, J A; Bogouch, A; Bohm, C; Bohm, J; Boisvert, V; Bold, T; Boldea, V; Boldyrev, A; Bondarenko, V G; Bondioli, M; Boonekamp, M; Booth, J R A; Bordoni, S; Borer, C; Borisov, A; Borissov, G; Borjanovic, I; Borroni, S; Bos, K; Boscherini, D; Bosman, M; Bosteels, M; Boterenbrood, H; Bouchami, J; Boudreau, J; Bouhova-Thacker, E V; Boulahouache, C; Bourdarios, C; Boyd, J; Boyko, I R; Bozovic-Jelisavcic, I; Bracinik, J; Braem, A; Branchini, P; Brandenburg, G W; Brandt, A; Brandt, G; Brandt, O; Bratzler, U; Brau, B; Brau, J E; Braun, H M; Brelier, B; Bremer, J; Brenner, R; Bressler, S; Breton, D; Brett, N D; Britton, D; Brochu, F M; Brock, I; Brock, R; Brodbeck, T J; Brodet, E; Broggi, F; Bromberg, C; Brooijmans, G; Brooks, W K; Brown, G; Brubaker, E; Bruckman de Renstrom, P A; Bruncko, D; Bruneliere, R; Brunet, S; Bruni, A; Bruni, G; Bruschi, M; Buanes, T; Bucci, F; Buchanan, J; Buchholz, P; Buckley, A G; Budagov, I A; Budick, B; Büscher, V; Bugge, L; Bulekov, O; Bunse, M; Buran, T; Burckhart, H; Burdin, S; Burgess, T; Burke, S; Busato, E; Bussey, P; Buszello, C P; Butin, F; Butler, B; Butler, J M; Buttar, C M; Butterworth, J M; Byatt, T; Caballero, J; Cabrera Urbán, S; Caforio, D; Cakir, O; Calafiura, P; Calderini, G; Calfayan, P; Calkins, R; Caloba, L P; Caloi, R; Calvet, D; Camarri, P; Cambiaghi, M; Cameron, D; Campabadal-Segura, F; Campana, S; Campanelli, M; Canale, V; Canelli, F; Canepa, A; Cantero, J; Capasso, L; Capeans-Garrido, M D M; Caprini, I; Caprini, M; Capua, M; Caputo, R; Caracinha, D; Caramarcu, C; Cardarelli, R; Carli, T; Carlino, G; Carminati, L; Caron, B; Caron, S; Carrillo Montoya, G D; Carron Montero, S; Carter, A A; Carter, J R; Carvalho, J; Casadei, D; Casado, M P; Cascella, M; Caso, C; Castaneda Hernadez, A M; Castaneda-Miranda, E; Castillo Gimenez, V; Castro, N; Cataldi, G; Catinaccio, A; Catmore, J R; Cattai, A; Cattani, G; Caughron, S; Cauz, D; Cavalleri, P; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Ceradini, F; Cerqueira, A S; Cerri, A; Cerrito, L; Cerutti, F; Cetin, S A; Cevenini, F; Chafaq, A; Chakraborty, D; Chan, K; Chapman, J D; Chapman, J W; Chareyre, E; Charlton, D G; Chavda, V; Cheatham, S; Chekanov, S; Chekulaev, S V; Chelkov, G A; Chen, H; Chen, S; Chen, T; Chen, X; Cheng, S; Cheplakov, A; Chepurnov, V F; Cherkaoui El Moursli, R; Tcherniatine, V; Chesneanu, D; Cheu, E; Cheung, S L; Chevalier, L; Chevallier, F; Chiarella, V; Chiefari, G; Chikovani, L; Childers, J T; Chilingarov, A; Chiodini, G; Chizhov, M; Choudalakis, G; Chouridou, S; Chren, D; Christidi, I A; Christov, A; Chromek-Burckhart, D; Chu, M L; Chudoba, J; Ciapetti, G; Ciftci, A K; Ciftci, R; Cinca, D; Cindro, V; Ciobotaru, M D; Ciocca, C; Ciocio, A; Cirilli, M; Citterio, M; Clark, A; Cleland, W; Clemens, J C; Clement, B; Clement, C; Clements, D; Coadou, Y; Cobal, M; Coccaro, A; Cochran, J; Coelli, S; Coggeshall, J; Cogneras, E; Cojocaru, C D; Colas, J; Cole, B; Colijn, A P; Collard, C; Collins, N J; Collins-Tooth, C; Collot, J; Colon, G; Coluccia, R; Conde Muiño, P; Coniavitis, E; Consonni, M; Constantinescu, S; Conta, C; Conventi, F; Cook, J; Cooke, M; Cooper, B D; Cooper-Sarkar, A M; Cooper-Smith, N J; Copic, K; Cornelissen, T; Corradi, M; Corriveau, F; Corso-Radu, A; Cortes-Gonzalez, A; Cortiana, G; Costa, G; Costa, M J; Costanzo, D; Costin, T; Côté, D; Coura Torres, R; Courneyea, L; Cowan, G; Cowden, C; Cox, B E; Cranmer, K; Cranshaw, J; Cristinziani, M; Crosetti, G; Crupi, R; Crépé-Renaudin, S; Cuenca Almenar, C; Cuhadar Donszelmann, T; Curatolo, M; Curtis, C J; Cwetanski, P; Czyczula, Z; D'Auria, S; D'Onofrio, M; D'Orazio, A; Da Silva, P V M; Da Via, C; Dabrowski, W; Dai, T; Dallapiccola, C; Dallison, S J; Daly, C H; Dam, M; Danielsson, H O; Dannheim, D; Dao, V; Darbo, G; Darlea, G L; Davey, W; Davidek, T; Davidson, N; Davidson, R; Davison, A R; Dawson, I; Dawson, J W; Daya, R K; De, K; de Asmundis, R; De Castro, S; De Castro Faria Salgado, P E; De Cecco, S; de Graat, J; De Groot, N; de Jong, P; De La Cruz Burelo, E; De La Taille, C; De Mora, L; De Oliveira Branco, M; De Pedis, D; De Salvo, A; De Sanctis, U; De Santo, A; De Vivie De Regie, J B; De Zorzi, G; Dean, S; Deberg, H; Dedes, G; Dedovich, D V; Defay, P O; Degenhardt, J; Dehchar, M; Del Papa, C; Del Peso, J; Del Prete, T; Dell'Acqua, A; Dell'Asta, L; Della Pietra, M; della Volpe, D; Delmastro, M; Delruelle, N; Delsart, P A; Deluca, C; Demers, S; Demichev, M; Demirkoz, B; Deng, J; Deng, W; Denisov, S P; Dennis, C; Derkaoui, J E; Derue, F; Dervan, P; Desch, K; Deviveiros, P O; Dewhurst, A; DeWilde, B; Dhaliwal, S; Dhullipudi, R; Di Ciaccio, A; Di Ciaccio, L; Di Domenico, A; Di Girolamo, A; Di Girolamo, B; Di Luise, S; Di Mattia, A; Di Nardo, R; Di Simone, A; Di Sipio, R; Diaz, M A; Diblen, F; Diehl, E B; Dietrich, J; Diglio, S; Dindar Yagci, K; Dingfelder, D J; Dionisi, C; Dita, P; Dita, S; Dittus, F; Djama, F; Djilkibaev, R; Djobava, T; do Vale, M A B; Do Valle Wemans, A; Dobbs, M; Dobos, D; Dobson, E; Dobson, M; Dodd, J; Dogan, O B; Doherty, T; Doi, Y; Dolejsi, J; Dolenc, I; Dolezal, Z; Dolgoshein, B A; Dohmae, T; Donega, M; Donini, J; Dopke, J; Doria, A; Dos Anjos, A; Dotti, A; Dova, M T; Doxiadis, A; Doyle, A T; Drasal, Z; Driouichi, C; Dris, M; Dubbert, J; Duchovni, E; Duckeck, G; Dudarev, A; Dudziak, F; Dührssen , M; Duflot, L; Dufour, M-A; Dunford, M; Duperrin, A; Duran-Yildiz, H; Dushkin, A; Duxfield, R; Dwuznik, M; Düren, M; Ebenstein, W L; Ebke, J; Eckert, S; Eckweiler, S; Edmonds, K; Edwards, C A; Eerola, P; Egorov, K; Ehrenfeld, W; Ehrich, T; Eifert, T; Eigen, G; Einsweiler, K; Eisenhandler, E; Ekelof, T; El Kacimi, M; Ellert, M; Elles, S; Ellinghaus, F; Ellis, K; Ellis, N; Elmsheuser, J; Elsing, M; Ely, R; Emeliyanov, D; Engelmann, R; Engl, A; Epp, B; Eppig, A; Epshteyn, V S; Ereditato, A; Eriksson, D; Ermoline, I; Ernst, J; Ernst, M; Ernwein, J; Errede, D; Errede, S; Ertel, E; Escalier, M; Escobar, C; Espinal Curull, X; Esposito, B; Etienne, F; Etienvre, A I; Etzion, E; Evans, H; Fabbri, L; Fabre, C; Faccioli, P; Facius, K; Fakhrutdinov, R M; Falciano, S; Falou, A C; Fang, Y; Fanti, M; Farbin, A; Farilla, A; Farley, J; Farooque, T; Farrington, S M; Farthouat, P; Fassi, F; Fassnacht, P; Fassouliotis, D; Fatholahzadeh, B; Fayard, L; Fayette, F; Febbraro, R; Federic, P; Fedin, O L; Fedorko, I; Fedorko, W; Feligioni, L; Felzmann, C U; Feng, C; Feng, E J; Fenyuk, A B; Ferencei, J; Ferland, J; Fernandes, B; Fernando, W; Ferrag, S; Ferrando, J; Ferrari, A; Ferrari, P; Ferrari, R; Ferrer, A; Ferrer, M L; Ferrere, D; Ferretti, C; Fiascaris, M; Fiedler, F; Filipcic, A; Filippas, A; Filthaut, F; Fincke-Keeler, M; Fiolhais, M C N; Fiorini, L; Firan, A; Fischer, G; Fisher, M J; Flechl, M; Fleck, I; Fleckner, J; Fleischmann, P; Fleischmann, S; Flick, T; Flores-Castillo, L R; Flowerdew, M J; Föhlisch, F; Fokitis, M; Fonseca Martin, T; Forbush, D A; Formica, A; Forti, A; Fortin, D; Foster, J M; Fournier, D; Foussat, A; Fowler, A J; Fowler, K; Fox, H; Francavilla, P; Franchino, S; Francis, D; Franklin, M; Franz, S; Fraternali, M; Fratina, S; Freestone, J; French, S T; Froeschl, R; Froidevaux, D; Frost, J A; Fukunaga, C; Fullana Torregrosa, E; Fuster, J; Gabaldon, C; Gabizon, O; Gadfort, T; Gadomski, S; Gagliardi, G; Gagnon, P; Galea, C; Gallas, E J; Gallas, M V; Gallop, B J; Gallus, P; Galyaev, E; Gan, K K; Gao, Y S; Gaponenko, A; Garcia-Sciveres, M; Garcí­a, C; Garcí­a Navarro, J E; Gardner, R W; Garelli, N; Garitaonandia, H; Garonne, V; Gatti, C; Gaudio, G; Gaumer, O; Gauzzi, P; Gavrilenko, I L; Gay, C; Gaycken, G; Gayde, J-C; Gazis, E N; Ge, P; Gee, C N P; Geich-Gimbel, Ch; Gellerstedt, K; Gemme, C; Genest, M H; Gentile, S; Georgatos, F; George, S; Gerlach, P; Gershon, A; Geweniger, C; Ghazlane, H; Ghez, P; Ghodbane, N; Giacobbe, B; Giagu, S; Giakoumopoulou, V; Giangiobbe, V; Gianotti, F; Gibbard, B; Gibson, A; Gibson, S M; Gilbert, L M; Gilchriese, M; Gilewsky, V; Gillberg, D; Gillman, A R; Gingrich, D M; Ginzburg, J; Giokaris, N; Giordani, M P; Giordano, R; Giovannini, P; Giraud, P F; Girtler, P; Giugni, D; Giusti, P; Gjelsten, B K; Gladilin, L K; Glasman, C; Glazov, A; Glitza, K W; Glonti, G L; Godfrey, J; Godlewski, J; Goebel, M; Göpfert, T; Goeringer, C; Gössling, C; Göttfert, T; Goggi, V; Goldfarb, S; Goldin, D; Golling, T; Gollub, N P; Gomes, A; Gomez Fajardo, L S; Gonçalo, R; Gonella, L; Gong, C; González de la Hoz, S; Gonzalez Silva, M L; Gonzalez-Sevilla, S; Goodson, J J; Goossens, L; Gorbounov, P A; Gordon, H A; Gorelov, I; Gorfine, G; Gorini, B; Gorini, E; Gorisek, A; Gornicki, E; Goryachev, S V; Goryachev, V N; Gosdzik, B; Gosselink, M; Gostkin, M I; Gough Eschrich, I; Gouighri, M; Goujdami, D; Goulette, M P; Goussiou, A G; Goy, C; Grabowska-Bold, I; Grafström, P; Grahn, K-J; Granado Cardoso, L; Grancagnolo, F; Grancagnolo, S; Grassi, V; Gratchev, V; Grau, N; Gray, H M; Gray, J A; Graziani, E; Green, B; Greenshaw, T; Greenwood, Z D; Gregor, I M; Grenier, P; Griesmayer, E; Griffiths, J; Grigalashvili, N; Grillo, A A; Grimm, K; Grinstein, S; Grishkevich, Y V; Groer, L S; Grognuz, J; Groh, M; Groll, M; Gross, E; Grosse-Knetter, J; Groth-Jensen, J; Grybel, K; Guarino, V J; Guicheney, C; Guida, A; Guillemin, T; Guler, H; Gunther, J; Guo, B; Gupta, A; Gusakov, Y; Gutierrez, A; Gutierrez, P; Guttman, N; Gutzwiller, O; Guyot, C; Gwenlan, C; Gwilliam, C B; Haas, A; Haas, S; Haber, C; Hackenburg, R; Hadavand, H K; Hadley, D R; Haefner, P; Härtel, R; Hajduk, Z; Hakobyan, H; Haller, J; Hamacher, K; Hamilton, A; Hamilton, S; Han, H; Han, L; Hanagaki, K; Hance, M; Handel, C; Hanke, P; Hansen, J R; Hansen, J B; Hansen, J D; Hansen, P H; Hansl-Kozanecka, T; Hansson, P; Hara, K; Hare, G A; Harenberg, T; Harrington, R D; Harris, O B; Harris, O M; Harrison, K; Hartert, J; Hartjes, F; Haruyama, T; Harvey, A; Hasegawa, S; Hasegawa, Y; Hashemi, K; Hassani, S; Hatch, M; Haug, F; Haug, S; Hauschild, M; Hauser, R; Havranek, M; Hawkes, C M; Hawkings, R J; Hawkins, D; Hayakawa, T; Hayward, H S; Haywood, S J; He, M; Head, S J; Hedberg, V; Heelan, L; Heim, S; Heinemann, B; Heisterkamp, S; Helary, L; Heller, M; Hellman, S; Helsens, C; Hemperek, T; Henderson, R C W; Henke, M; Henrichs, A; Henriques-Correia, A M; Henrot-Versille, S; Hensel, C; Henß, T; Hershenhorn, A D; Herten, G; Hertenberger, R; Hervas, L; Hessey, N P; Hidvegi, A; Higón-Rodriguez, E; Hill, D; Hill, J C; Hiller, K H; Hillier, S J; Hinchliffe, I; Hirose, M; Hirsch, F; Hobbs, J; Hod, N; Hodgkinson, M C; Hodgson, P; Hoecker, A; Hoeferkamp, M R; Hoffman, J; Hoffmann, D; Hohlfeld, M; Holmgren, S O; Holy, T; Holzbauer, J L; Homma, Y; Homola, P; Horazdovsky, T; Hori, T; Horn, C; Horner, S; Horvat, S; Hostachy, J-Y; Hou, S; Houlden, M A; Hoummada, A; Howe, T; Hrivnac, J; Hryn'ova, T; Hsu, P J; Hsu, S-C; Huang, G S; Hubacek, Z; Hubaut, F; Huegging, F; Hughes, E W; Hughes, G; Hughes-Jones, R E; Hurst, P; Hurwitz, M; Husemann, U; Huseynov, N; Huston, J; Huth, J; Iacobucci, G; Iakovidis, G; Ibragimov, I; Iconomidou-Fayard, L; Idarraga, J; Iengo, P; Igonkina, O; Ikegami, Y; Ikeno, M; Ilchenko, Y; Iliadis, D; Ilyushenka, Y; Imori, M; Ince, T; Ioannou, P; Iodice, M; Irles-Quiles, A; Ishikawa, A; Ishino, M; Ishmukhametov, R; Isobe, T; Issakov, V; Issever, C; Istin, S; Itoh, Y; Ivashin, A V; Iwanski, W; Iwasaki, H; Izen, J M; Izzo, V; Jackson, J N; Jackson, P; Jaekel, M; Jahoda, M; Jain, V; Jakobs, K; Jakobsen, S; Jakubek, J; Jana, D; Jansen, E; Jantsch, A; Janus, M; Jared, R C; Jarlskog, G; Jarron, P; Jeanty, L; Jelen, K; Jen-La Plante, I; Jenni, P; Jez, P; Jézéquel, S; Ji, W; Jia, J; Jiang, Y; Jimenez Belenguer, M; Jin, G; Jin, S; Jinnouchi, O; Joffe, D; Johansen, M; Johansson, K E; Johansson, P; Johnert, S; Johns, K A; Jon-And, K; Jones, G; Jones, R W L; Jones, T W; Jones, T J; Jonsson, O; Joos, D; Joram, C; Jorge, P M; Juranek, V; Jussel, P; Kabachenko, V V; Kabana, S; Kaci, M; Kaczmarska, A; Kado, M; Kagan, H; Kagan, M; Kaiser, S; Kajomovitz, E; Kalinovskaya, L V; Kalinowski, A; Kama, S; Kanaya, N; Kaneda, M; Kantserov, V A; Kanzaki, J; Kaplan, B; Kapliy, A; Kaplon, J; Karagounis, M; Karagoz Unel, M; Kartvelishvili, V; Karyukhin, A N; Kashif, L; Kasmi, A; Kass, R D; Kastanas, A; Kastoryano, M; Kataoka, M; Kataoka, Y; Katsoufis, E; Katzy, J; Kaushik, V; Kawagoe, K; Kawamoto, T; Kawamura, G; Kayl, M S; Kayumov, F; Kazanin, V A; Kazarinov, M Y; Kazi, S I; Keates, J R; Keeler, R; Keener, P T; Kehoe, R; Keil, M; Kekelidze, G D; Kelly, M; Kennedy, J; Kenyon, M; Kepka, O; Kerschen, N; Kersevan, B P; Kersten, S; Kessoku, K; Khakzad, M; Khalil-zada, F; Khandanyan, H; Khanov, A; Kharchenko, D; Khodinov, A; Kholodenko, A G; Khomich, A; Khoriauli, G; Khovanskiy, N; Khovanskiy, V; Khramov, E; Khubua, J; Kilvington, G; Kim, H; Kim, M S; Kim, P C; Kim, S H; Kind, O; Kind, P; King, B T; Kirk, J; Kirsch, G P; Kirsch, L E; Kiryunin, A E; Kisielewska, D; Kittelmann, T; Kiyamura, H; Kladiva, E; Klein, M; Klein, U; Kleinknecht, K; Klemetti, M; Klier, A; Klimentov, A; Klingenberg, R; Klinkby, E B; Klioutchnikova, T; Klok, P F; Klous, S; Kluge, E-E; Kluge, T; Kluit, P; Klute, M; Kluth, S; Knecht, N S; Kneringer, E; Ko, B R; Kobayashi, T; Kobel, M; Koblitz, B; Kocian, M; Kocnar, A; Kodys, P; Köneke, K; König, A C; Köpke, L; Koetsveld, F; Koevesarki, P; Koffas, T; Koffeman, E; Kohn, F; Kohout, Z; Kohriki, T; Kokott, T; Kolanoski, H; Kolesnikov, V; Koletsou, I; Koll, J; Kollar, D; Kolos, S; Kolya, S D; Komar, A A; Komaragiri, J R; Kondo, T; Kono, T; Kononov, A I; Konoplich, R; Konovalov, S P; Konstantinidis, N; Koperny, S; Korcyl, K; Kordas, K; Koreshev, V; Korn, A; Korolkov, I; Korolkova, E V; Korotkov, V A; Kortner, O; Kostka, P; Kostyukhin, V V; Kotamäki, M J; Kotov, S; Kotov, V M; Kotov, K Y; Koupilova, Z; Kourkoumelis, C; Koutsman, A; Kowalewski, R; Kowalski, H; Kowalski, T Z; Kozanecki, W; Kozhin, A S; Kral, V; Kramarenko, V A; Kramberger, G; Krasny, M W; Krasznahorkay, A; Kreisel, A; Krejci, F; Krepouri, A; Kretzschmar, J; Krieger, P; Krobath, G; Kroeninger, K; Kroha, H; Kroll, J; Kroseberg, J; Krstic, J; Kruchonak, U; Krüger, H; Krumshteyn, Z V; Kubota, T; Kuehn, S; Kugel, A; Kuhl, T; Kuhn, D; Kukhtin, V; Kulchitsky, Y; Kuleshov, S; Kummer, C; Kuna, M; Kupco, A; Kurashige, H; Kurata, M; Kurchaninov, L L; Kurochkin, Y A; Kus, V; Kuykendall, W; Kuznetsova, E; Kvasnicka, O; Kwee, R; La Rosa, M; La Rotonda, L; Labarga, L; Labbe, J; Lacasta, C; Lacava, F; Lacker, H; Lacour, D; Lacuesta, V R; Ladygin, E; Lafaye, R; Laforge, B; Lagouri, T; Lai, S; Lamanna, M; Lampen, C L; Lampl, W; Lancon, E; Landgraf, U; Landon, M P J; Lane, J L; Lankford, A J; Lanni, F; Lantzsch, K; Lanza, A; Laplace, S; Lapoire, C; Laporte, J F; Lari, T; Larionov, A V; Larner, A; Lasseur, C; Lassnig, M; Laurelli, P; Lavrijsen, W; Laycock, P; Lazarev, A B; Lazzaro, A; Le Dortz, O; Le Guirriec, E; Le Maner, C; Le Menedeu, E; Le Vine, M; Leahu, M; Lebedev, A; Lebel, C; LeCompte, T; Ledroit-Guillon, F; Lee, H; Lee, J S H; Lee, S C; Lefebvre, M; Legendre, M; LeGeyt, B C; Legger, F; Leggett, C; Lehmacher, M; Lehmann Miotto, G; Lei, X; Leitner, R; Lelas, D; Lellouch, D; Lellouch, J; Leltchouk, M; Lendermann, V; Leney, K J C; Lenz, T; Lenzen, G; Lenzi, B; Leonhardt, K; Leroy, C; Lessard, J-R; Lester, C G; Leung Fook Cheong, A; Levêque, J; Levin, D; Levinson, L J; Levitski, M S; Levonian, S; Lewandowska, M; Leyton, M; Li, H; Li, J; Li, S; Li, X; Liang, Z; Liang, Z; Liberti, B; Lichard, P; Lichtnecker, M; Lie, K; Liebig, W; Liko, D; Lilley, J N; Lim, H; Limosani, A; Limper, M; Lin, S C; Lindsay, S W; Linhart, V; Linnemann, J T; Liolios, A; Lipeles, E; Lipinsky, L; Lipniacka, A; Liss, T M; Lissauer, D; Litke, A M; Liu, C; Liu, D; Liu, H; Liu, J B; Liu, M; Liu, S; Liu, T; Liu, Y; Livan, M; Lleres, A; Lloyd, S L; Lobodzinska, E; Loch, P; Lockman, W S; Lockwitz, S; Loddenkoetter, T; Loebinger, F K; Loginov, A; Loh, C W; Lohse, T; Lohwasser, K; Lokajicek, M; Loken, J; Lopes, L; Lopez Mateos, D; Losada, M; Loscutoff, P; Losty, M J; Lou, X; Lounis, A; Loureiro, K F; Lovas, L; Love, J; Love, P; Lowe, A J; Lu, F; Lu, J; Lubatti, H J; Luci, C; Lucotte, A; Ludwig, A; Ludwig, D; Ludwig, I; Ludwig, J; Luehring, F; Luisa, L; Lumb, D; Luminari, L; Lund, E; Lund-Jensen, B; Lundberg, B; Lundberg, J; Lundquist, J; Lutz, G; Lynn, D; Lys, J; Lytken, E; Ma, H; Ma, L L; Maccarrone, G; Macchiolo, A; Macek, B; Machado Miguens, J; Mackeprang, R; Madaras, R J; Mader, W F; Maenner, R; Maeno, T; Mättig, P; Mättig, S; Magalhaes Martins, P J; Magradze, E; Magrath, C A; Mahalalel, Y; Mahboubi, K; Mahmood, A; Mahout, G; Maiani, C; Maidantchik, C; Maio, A; Majewski, S; Makida, Y; Makouski, M; Makovec, N; Malecki, Pa; Malecki, P; Maleev, V P; Malek, F; Mallik, U; Malon, D; Maltezos, S; Malyshev, V; Malyukov, S; Mambelli, M; Mameghani, R; Mamuzic, J; Manabe, A; Mandelli, L; Mandic, I; Mandrysch, R; Maneira, J; Mangeard, P S; Manjavidze, I D; Manousakis-Katsikakis, A; Mansoulie, B; Mapelli, A; Mapelli, L; March, L; Marchand, J F; Marchese, F; Marcisovsky, M; Marino, C P; Marques, C N; Marroquim, F; Marshall, R; Marshall, Z; Martens, F K; Marti i Garcia, S; Martin, A J; Martin, A J; Martin, B; Martin, B; Martin, F F; Martin, J P; Martin, T A; Martin dit Latour, B; Martinez, M; Martinez Outschoorn, V; Martini, A; Martynenko, V; Martyniuk, A C; Maruyama, T; Marzano, F; Marzin, A; Masetti, L; Mashimo, T; Mashinistov, R; Masik, J; Maslennikov, A L; Massaro, G; Massol, N; Mastroberardino, A; Masubuchi, T; Mathes, M; Matricon, P; Matsumoto, H; Matsunaga, H; Matsushita, T; Mattravers, C; Maxfield, S J; May, E N; Mayne, A; Mazini, R; Mazur, M; Mazzanti, M; Mazzanti, P; Mc Donald, J; Mc Kee, S P; McCarn, A; McCarthy, R L; McCubbin, N A; McFarlane, K W; McGlone, H; Mchedlidze, G; McLaren, R A; McMahon, S J; McMahon, T R; McPherson, R A; Meade, A; Mechnich, J; Mechtel, M; Medinnis, M; Meera-Lebbai, R; Meguro, T M; Mehdiyev, R; Mehlhase, S; Mehta, A; Meier, K; Meirose, B; Melamed-Katz, A; Mellado Garcia, B R; Meng, Z; Menke, S; Meoni, E; Merkl, D; Mermod, P; Merola, L; Meroni, C; Merritt, F S; Messina, A M; Messmer, I; Metcalfe, J; Mete, A S; Meyer, J-P; Meyer, J; Meyer, T C; Meyer, W T; Miao, J; Micu, L; Middleton, R P; Migas, S; Mijovic, L; Mikenberg, G; Mikuz, M; Miller, D W; Mills, W J; Mills, C M; Milov, A; Milstead, D A; Minaenko, A A; Miñano, M; Minashvili, I A; Mincer, A I; Mindur, B; Mineev, M; Mir, L M; Mirabelli, G; Misawa, S; Miscetti, S; Misiejuk, A; Mitrevski, J; Mitsou, V A; Miyagawa, P S; Mjörnmark, J U; Mladenov, D; Moa, T; Mockett, P; Moed, S; Moeller, V; Mönig, K; Möser, N; Mohn, B; Mohr, W; Mohrdieck-Möck, S; Moles-Valls, R; Molina-Perez, J; Moloney, G; Monk, J; Monnier, E; Montesano, S; Monticelli, F; Moore, R W; Mora-Herrera, C; Moraes, A; Morais, A; Morel, J; Morello, G; Moreno, D; Moreno Llácer, M; Morettini, P; Morii, M; Morley, A K; Mornacchi, G; Morozov, S V; Morris, J D; Moser, H G; Mosidze, M; Moss, J; Mount, R; Mountricha, E; Mouraviev, S V; Moyse, E J W; Mudrinic, M; Mueller, F; Mueller, J; Mueller, K; Müller, T A; Muenstermann, D; Muir, A; Murillo Garcia, R; Murray, W J; Mussche, I; Musto, E; Myagkov, A G; Myska, M; Nadal, J; Nagai, K; Nagano, K; Nagasaka, Y; Nairz, A M; Nakamura, K; Nakano, I; Nakatsuka, H; Nanava, G; Napier, A; Nash, M; Nation, N R; Nattermann, T; Naumann, T; Navarro, G; Nderitu, S K; Neal, H A; Nebot, E; Nechaeva, P; Negri, A; Negri, G; Nelson, A; Nelson, T K; Nemecek, S; Nemethy, P; Nepomuceno, A A; Nessi, M; Neubauer, M S; Neusiedl, A; Neves, R N; Nevski, P; Newcomer, F M; Nicholson, C; Nickerson, R B; Nicolaidou, R; Nicolas, L; Nicoletti, G; Niedercorn, F; Nielsen, J; Nikiforov, A; Nikolaev, K; Nikolic-Audit, I; Nikolopoulos, K; Nilsen, H; Nilsson, P; Nisati, A; Nishiyama, T; Nisius, R; Nodulman, L; Nomachi, M; Nomidis, I; Nomoto, H; Nordberg, M; Nordkvist, B; Notz, D; Novakova, J; Nozaki, M; Nozicka, M; Nugent, I M; Nuncio-Quiroz, A-E; Nunes Hanninger, G; Nunnemann, T; Nurse, E; O'Neil, D C; O'Shea, V; Oakham, F G; Oberlack, H; Ochi, A; Oda, S; Odaka, S; Odier, J; Odino, G A; Ogren, H; Oh, S H; Ohm, C C; Ohshima, T; Ohshita, H; Ohsugi, T; Okada, S; Okawa, H; Okumura, Y; Olcese, M; Olchevski, A G; Oliveira, M; Oliveira Damazio, D; Oliver, J; Oliver Garcia, E; Olivito, D; Olszewski, A; Olszowska, J; Omachi, C; Onofre, A; Onyisi, P U E; Oram, C J; Ordonez, G; Oreglia, M J; Oren, Y; Orestano, D; Orlov, I; Oropeza Barrera, C; Orr, R S; Ortega, E O; Osculati, B; Osuna, C; Otec, R; Ottersbach, J P; Ould-Saada, F; Ouraou, A; Ouyang, Q; Owen, M; Owen, S; Ozcan, V E; Ozone, K; Ozturk, N; Pacheco Pages, A; Padhi, S; Padilla Aranda, C; Paganis, E; Pahl, C; Paige, F; Pajchel, K; Pal, A; Palestini, S; Pallin, D; Palma, A; Palmer, J D; Pan, Y B; Panagiotopoulou, E; Panes, B; Panikashvili, N; Panitkin, S; Pantea, D; Panuskova, M; Paolone, V; Papadopoulou, Th D; Park, S J; Park, W; Parker, M A; Parker, S I; Parodi, F; Parsons, J A; Parzefall, U; Pasqualucci, E; Passardi, G; Passeri, A; Pastore, F; Pastore, Fr; Pásztor, G; Pataraia, S; Pater, J R; Patricelli, S; Patwa, A; Pauly, T; Peak, L S; Pecsy, M; Pedraza Morales, M I; Peleganchuk, S V; Peng, H; Penson, A; Penwell, J; Perantoni, M; Perez, K; Perez Codina, E; Pérez García-Estañ, M T; Perez Reale, V; Perini, L; Pernegger, H; Perrino, R; Perrodo, P; Persembe, S; Perus, P; Peshekhonov, V D; Petersen, B A; Petersen, J; Petersen, T C; Petit, E; Petridou, C; Petrolo, E; Petrucci, F; Petschull, D; Petteni, M; Pezoa, R; Pfeifer, B; Phan, A; Phillips, A W; Piacquadio, G; Piccinini, M; Piegaia, R; Pilcher, J E; Pilkington, A D; Pina, J; Pinamonti, M; Pinfold, J L; Ping, J; Pinto, B; Pirotte, O; Pizio, C; Placakyte, R; Plamondon, M; Plano, W G; Pleier, M-A; Poblaguev, A; Poddar, S; Podlyski, F; Poffenberger, P; Poggioli, L; Pohl, M; Polci, F; Polesello, G; Policicchio, A; Polini, A; Poll, J; Polychronakos, V; Pomarede, D M; Pomeroy, D; Pommès, K; Pontecorvo, L; Pope, B G; Popovic, D S; Poppleton, A; Popule, J; Portell Bueso, X; Porter, R; Pospelov, G E; Pospichal, P; Pospisil, S; Potekhin, M; Potrap, I N; Potter, C J; Potter, C T; Potter, K P; Poulard, G; Poveda, J; Prabhu, R; Pralavorio, P; Prasad, S; Pravahan, R; Preda, T; Pretzl, K; Pribyl, L; Price, D; Price, L E; Prichard, P M; Prieur, D; Primavera, M; Prokofiev, K; Prokoshin, F; Protopopescu, S; Proudfoot, J; Prudent, X; Przysiezniak, H; Psoroulas, S; Ptacek, E; Puigdengoles, C; Purdham, J; Purohit, M; Puzo, P; Pylypchenko, Y; Qi, M; Qian, J; Qian, W; Qian, Z; Qin, Z; Qing, D; Quadt, A; Quarrie, D R; Quayle, W B; Quinonez, F; Raas, M; Radeka, V; Radescu, V; Radics, B; Rador, T; Ragusa, F; Rahal, G; Rahimi, A M; Rahm, D; Rajagopalan, S; Rammes, M; Ratoff, P N; Rauscher, F; Rauter, E; Raymond, M; Read, A L; Rebuzzi, D M; Redelbach, A; Redlinger, G; Reece, R; Reeves, K; Reinherz-Aronis, E; Reinsch, A; Reisinger, I; Reljic, D; Rembser, C; Ren, Z L; Renkel, P; Rescia, S; Rescigno, M; Resconi, S; Resende, B; Reznicek, P; Rezvani, R; Richards, A; Richards, R A; Richter, D; Richter, R; Richter-Was, E; Ridel, M; Rieke, S; Rijpstra, M; Rijssenbeek, M; Rimoldi, A; Rinaldi, L; Rios, R R; Riu, I; Rivoltella, G; Rizatdinova, F; Rizvi, E R; Roa-Romero, D A; Robertson, S H; Robichaud-Veronneau, A; Robinson, D; Robinson, M; Robson, A; Rocha de Lima, J G; Roda, C; Rodriguez, D; Rodriguez Garcia, Y; Roe, S; Røhne, O; Rojo, V; Rolli, S; Romaniouk, A; Romanov, V M; Romeo, G; Romero-Maltrana, D; Roos, L; Ros, E; Rosati, S; Rosenbaum, G A; Rosenberg, E I; Rosselet, L; Rossi, L P; Rotaru, M; Rothberg, J; Rottländer, I; Rousseau, D; Royon, C R; Rozanov, A; Rozen, Y; Ruan, X; Ruckert, B; Ruckstuhl, N; Rud, V I; Rudolph, G; Rühr, F; Ruggieri, F; Ruiz-Martinez, A; Rumyantsev, L; Rusakovich, N A; Rutherfoord, J P; Ruwiedel, C; Ruzicka, P; Ryabov, Y F; Ryadovikov, V; Ryan, P; Rybkin, G; Rzaeva, S; Saavedra, A F; Sadrozinski, H F-W; Sadykov, R; Sakamoto, H; Salamanna, G; Salamon, A; Saleem, M; Salihagic, D; Salnikov, A; Salt, J; Salvachua-Ferrando, B M; Salvatore, D; Salvatore, F; Salvucci, A; Salzburger, A; Sampsonidis, D; Samset, B H; Sanchis Lozano, M A; Sandaker, H; Sander, H G; Sanders, M P; Sandhoff, M; Sandstroem, R; Sandvoss, S; Sankey, D P C; Sanny, B; Sansoni, A; Santamarina Rios, C; Santi, L; Santoni, C; Santonico, R; Santos, D; Santos, J; Saraiva, J G; Sarangi, T; Sarkisyan-Grinbaum, E; Sarri, F; Sasaki, O; Sasaki, T; Sasao, N; Satsounkevitch, I; Sauvage, G; Savard, P; Savine, A Y; Savinov, V; Sawyer, L; Saxon, D H; Says, L P; Sbarra, C; Sbrizzi, A; Scannicchio, D A; Schaarschmidt, J; Schacht, P; Schäfer, U; Schaetzel, S; Schaffer, A C; Schaile, D; Schamberger, R D; Schamov, A G; Schegelsky, V A; Scheirich, D; Schernau, M; Scherzer, M I; Schiavi, C; Schieck, J; Schioppa, M; Schlenker, S; Schlereth, J L; Schmid, P; Schmidt, M P; Schmieden, K; Schmitt, C; Schmitz, M; Schott, M; Schouten, D; Schovancova, J; Schram, M; Schreiner, A; Schroeder, C; Schroer, N; Schroers, M; Schuler, G; Schultes, J; Schultz-Coulon, H-C; Schumacher, J; Schumacher, M; Schumm, B A; Schune, Ph; Schwanenberger, C; Schwartzman, A; Schwemling, Ph; Schwienhorst, R; Schwierz, R; Schwindling, J; Scott, W G; Searcy, J; Sedykh, E; Segura, E; Seidel, S C; Seiden, A; Seifert, F; Seixas, J M; Sekhniaidze, G; Seliverstov, D M; Sellden, B; Seman, M; Semprini-Cesari, N; Serfon, C; Serin, L; Seuster, R; Severini, H; Sevior, M E; Sfyrla, A; Shamim, M; Shan, L Y; Shank, J T; Shao, Q T; Shapiro, M; Shatalov, P B; Shaver, L; Shaw, C; Shaw, K; Sherman, D; Sherwood, P; Shibata, A; Shimojima, M; Shin, T; Shmeleva, A; Shochet, M J; Shupe, M A; Sicho, P; Sidoti, A; Siebel, A; Siegert, F; Siegrist, J; Sijacki, Dj; Silbert, O; Silva, J; Silver, Y; Silverstein, D; Silverstein, S B; Simak, V; Simic, Lj; Simion, S; Simmons, B; Simonyan, M; Sinervo, P; Sinev, N B; Sipica, V; Siragusa, G; Sisakyan, A N; Sivoklokov, S Yu; Sjoelin, J; Sjursen, T B; Skubic, P; Skvorodnev, N; Slater, M; Slavicek, T; Sliwa, K; Sloper, J; Sluka, T; Smakhtin, V; Smirnov, S Yu; Smirnov, Y; Smirnova, L N; Smirnova, O; Smith, B C; Smith, D; Smith, K M; Smizanska, M; Smolek, K; Snesarev, A A; Snow, S W; Snow, J; Snuverink, J; Snyder, S; Soares, M; Sobie, R; Sodomka, J; Soffer, A; Solans, C A; Solar, M; Solfaroli-Camillocci, E; Solodkov, A A; Solovyanov, O V; Soluk, R; Sondericker, J; Sopko, V; Sopko, B; Sosebee, M; Sosnovtsev, V V; Sospedra-Suay, L; Soukharev, A; Spagnolo, S; Spanò, F; Speckmayer, P; Spencer, E; Spighi, R; Spigo, G; Spila, F; Spiwoks, R; Spousta, M; Spreitzer, T; Spurlock, B; St Denis, R D; Stahl, T; Stamen, R; Stancu, S N; Stanecka, E; Stanek, R W; Stanescu, C; Stapnes, S; Starchenko, E A; Stark, J; Staroba, P; Starovoitov, P; Stastny, J; Staude, A; Stavina, P; Stavropoulos, G; Steinbach, P; Steinberg, P; Stekl, I; Stelzer, B; Stelzer, H J; Stelzer-Chilton, O; Stenzel, H; Stevenson, K; Stewart, G; Stockton, M C; Stoerig, K; Stoicea, G; Stonjek, S; Strachota, P; Stradling, A; Straessner, A; Strandberg, J; Strandberg, S; Strandlie, A; Strauss, M; Strizenec, P; Ströhmer, R; Strom, D M; Strong, J A; Stroynowski, R; Strube, J; Stugu, B; Stumer, I; Soh, D A; Su, D; Suchkov, S I; Sugaya, Y; Sugimoto, T; Suhr, C; Suk, M; Sulin, V V; Sultansoy, S; Sumida, T; Sun, X; Sundermann, J E; Suruliz, K; Sushkov, S; Susinno, G; Sutton, M R; Suzuki, T; Suzuki, Y; Sviridov, Yu M; Sykora, I; Sykora, T; Szymocha, T; Sánchez, J; Ta, D; Tackmann, K; Taffard, A; Tafirout, R; Taga, A; Takahashi, Y; Takai, H; Takashima, R; Takeda, H; Takeshita, T; Talby, M; Talyshev, A; Tamsett, M C; Tanaka, J; Tanaka, R; Tanaka, S; Tanaka, S; Tappern, G P; Tapprogge, S; Tardif, D; Tarem, S; Tarrade, F; Tartarelli, G F; Tas, P; Tasevsky, M; Tassi, E; Taylor, C; Taylor, F E; Taylor, G N; Taylor, R P; Taylor, W; Teixeira-Dias, P; Ten Kate, H; Teng, P K; Terada, S; Terashi, K; Terron, J; Terwort, M; Testa, M; Teuscher, R J; Tevlin, C M; Thadome, J; Thananuwong, R; Thioye, M; Thoma, S; Thomas, J P; Thomas, T L; Thompson, E N; Thompson, P D; Thompson, P D; Thompson, R J; Thompson, A S; Thomson, E; Thun, R P; Tic, T; Tikhomirov, V O; Tikhonov, Y A; Timmermans, C J W P; Tipton, P; Tique-Aires-Viegas, F J; Tisserant, S; Tobias, J; Toczek, B; Todorov, T; Todorova-Nova, S; Toggerson, B; Tojo, J; Tokár, S; Tokushuku, K; Tollefson, K; Tomasek, L; Tomasek, M; Tomasz, F; Tomoto, M; Tompkins, D; Tompkins, L; Toms, K; Tong, G; Tonoyan, A; Topfel, C; Topilin, N D; Torrence, E; Torró Pastor, E; Toth, J; Touchard, F; Tovey, D R; Tovey, S N; Trefzger, T; Tremblet, L; Tricoli, A; Trigger, I M; Trincaz-Duvoid, S; Trinh, T N; Tripiana, M F; Triplett, N; Trivedi, A; Trocmé, B; Troncon, C; Trzupek, A; Tsarouchas, C; Tseng, J C-L; Tsiafis, I; Tsiakiris, M; Tsiareshka, P V; Tsionou, D; Tsipolitis, G; Tsiskaridze, V; Tskhadadze, E G; Tsukerman, I I; Tsulaia, V; Tsung, J-W; Tsuno, S; Tsybychev, D; Turala, M; Turecek, D; Turk Cakir, I; Turlay, E; Tuts, P M; Twomey, M S; Tylmad, M; Tyndel, M; Tzanakos, G; Uchida, K; Ueda, I; Uhlenbrock, M; Uhrmacher, M; Ukegawa, F; Unal, G; Underwood, D G; Undrus, A; Unel, G; Unno, Y; Urbaniec, D; Urkovsky, E; Urquijo, P; Urrejola, P; Usai, G; Uslenghi, M; Vacavant, L; Vacek, V; Vachon, B; Vahsen, S; Valenta, J; Valente, P; Valentinetti, S; Valkar, S; Valladolid Gallego, E; Vallecorsa, S; Valls Ferrer, J A; Van Berg, R; van der Graaf, H; van der Kraaij, E; van der Poel, E; Van Der Ster, D; van Eldik, N; van Gemmeren, P; van Kesteren, Z; van Vulpen, I; Vandelli, W; Vandoni, G; Vaniachine, A; Vankov, P; Vannucci, F; Varela Rodriguez, F; Vari, R; Varnes, E W; Varouchas, D; Vartapetian, A; Varvell, K E; Vasilyeva, L; Vassilakopoulos, V I; Vazeille, F; Vegni, G; Veillet, J J; Vellidis, C; Veloso, F; Veness, R; Veneziano, S; Ventura, A; Ventura, D; Venturi, M; Venturi, N; Vercesi, V; Verducci, M; Verkerke, W; Vermeulen, J C; Vetterli, M C; Vichou, I; Vickey, T; Viehhauser, G H A; Villa, M; Villani, E G; Villaplana Perez, M; Villate, J; Vilucchi, E; Vincter, M G; Vinek, E; Vinogradov, V B; Viret, S; Virzi, J; Vitale, A; Vitells, O V; Vivarelli, I; Vives Vaques, F; Vlachos, S; Vlasak, M; Vlasov, N; Vogt, H; Vokac, P; Volpi, M; Volpini, G; von der Schmitt, H; von Loeben, J; von Radziewski, H; von Toerne, E; Vorobel, V; Vorobiev, A P; Vorwerk, V; Vos, M; Voss, R; Voss, T T; Vossebeld, J H; Vranjes, N; Vranjes Milosavljevic, M; Vrba, V; Vreeswijk, M; Vu Anh, T; Vudragovic, D; Vuillermet, R; Vukotic, I; Wagner, P; Wahlen, H; Walbersloh, J; Walder, J; Walker, R; Walkowiak, W; Wall, R; Wang, C; Wang, H; Wang, J; Wang, J C; Wang, S M; Ward, C P; Warsinsky, M; Wastie, R; Watkins, P M; Watson, A T; Watson, M F; Watts, G; Watts, S; Waugh, A T; Waugh, B M; Webel, M; Weber, J; Weber, M D; Weber, M; Weber, M S; Weber, P; Weidberg, A R; Weingarten, J; Weiser, C; Wellenstein, H; Wells, P S; Wen, M; Wenaus, T; Wendler, S; Wengler, T; Wenig, S; Wermes, N; Werner, M; Werner, P; Werth, M; Werthenbach, U; Wessels, M; Whalen, K; Wheeler-Ellis, S J; Whitaker, S P; White, A; White, M J; White, S; Whiteson, D; Whittington, D; Wicek, F; Wicke, D; Wickens, F J; Wiedenmann, W; Wielers, M; Wienemann, P; Wiglesworth, C; Wiik, L A M; Wildauer, A; Wildt, M A; Wilhelm, I; Wilkens, H G; Williams, E; Williams, H H; Willis, W; Willocq, S; Wilson, J A; Wilson, M G; Wilson, A; Wingerter-Seez, I; Winklmeier, F; Wittgen, M; Wolter, M W; Wolters, H; Wosiek, B K; Wotschack, J; Woudstra, M J; Wraight, K; Wright, C; Wright, D; Wrona, B; Wu, S L; Wu, X; Wulf, E; Xella, S; Xie, S; Xie, Y; Xu, D; Xu, N; Yamada, M; Yamamoto, A; Yamamoto, S; Yamamura, T; Yamanaka, K; Yamaoka, J; Yamazaki, T; Yamazaki, Y; Yan, Z; Yang, H; Yang, U K; Yang, Y; Yang, Z; Yao, W-M; Yao, Y; Yasu, Y; Ye, J; Ye, S; Yilmaz, M; Yoosoofmiya, R; Yorita, K; Yoshida, R; Young, C; Youssef, S P; Yu, D; Yu, J; Yu, M; Yu, X; Yuan, J; Yuan, L; Yurkewicz, A; Zaidan, R; Zaitsev, A M; Zajacova, Z; Zambrano, V; Zanello, L; Zarzhitsky, P; Zaytsev, A; Zeitnitz, C; Zeller, M; Zema, P F; Zemla, A; Zendler, C; Zenin, O; Zenis, T; Zenonos, Z; Zenz, S; Zerwas, D; Zevi della Porta, G; Zhan, Z; Zhang, H; Zhang, J; Zhang, Q; Zhang, X; Zhao, L; Zhao, T; Zhao, Z; Zhemchugov, A; Zheng, S; Zhong, J; Zhou, B; Zhou, N; Zhou, Y; Zhu, C G; Zhu, H; Zhu, Y; Zhuang, X; Zhuravlov, V; Zilka, B; Zimmermann, R; Zimmermann, S; Zimmermann, S; Ziolkowski, M; Zitoun, R; Zivkovic, L; Zmouchko, V V; Zobernig, G; Zoccoli, A; zur Nedden, M; Zutshi, V

    2010-01-01

    The ATLAS liquid argon calorimeter has been operating continuously since August 2006. At this time, only part of the calorimeter was readout, but since the beginning of 2008, all calorimeter cells have been connected to the ATLAS readout system in preparation for LHC collisions. This paper gives an overview of the liquid argon calorimeter performance measured in situ with random triggers, calibration data, cosmic muons, and LHC beam splash events. Results on the detector operation, timing performance, electronics noise, and gain stability are presented. High energy deposits from radiative cosmic muons and beam splash events allow to check the intrinsic constant term of the energy resolution. The uniformity of the electromagnetic barrel calorimeter response along eta (averaged over phi) is measured at the percent level using minimum ionizing cosmic muons. Finally, studies of electromagnetic showers from radiative muons have been used to cross-check the Monte Carlo simulation. The performance results obtained u...

  7. Breakdown voltage of metal-oxide resistors in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Bagby, L. F. [Fermilab; Gollapinni, S. [Kansas State U.; James, C. C. [Fermilab; Jones, B. J.P. [MIT; Jostlein, H. [Fermilab; Lockwitz, S. [Fermilab; Naples, D. [Pittsburgh U.; Raaf, J. L. [Fermilab; Rameika, R. [Fermilab; Schukraft, A. [Fermilab; Strauss, T. [Bern U., LHEP; Weber, M. S. [Bern U., LHEP; Wolbers, S. A. [Fermilab

    2014-11-07

    We characterized a sample of metal-oxide resistors and measured their breakdown voltage in liquid argon by applying high voltage (HV) pulses over a 3 second period. This test mimics the situation in a HV-divider chain when a breakdown occurs and the voltage across resistors rapidly rise from the static value to much higher values. All resistors had higher breakdown voltages in liquid argon than their vendor ratings in air at room temperature. Failure modes range from full destruction to coating damage. In cases where breakdown was not catastrophic, subsequent breakdown voltages were lower in subsequent measuring runs. One resistor type withstands 131 kV pulses, the limit of the test setup.

  8. A pressurized argon gas TPC as DUNE near detector

    CERN Document Server

    Martin-Albo, J

    2016-01-01

    DUNE is a new international experiment for neutrino physics and nucleon decay searches. It will consist of two detectors, about 1300 km apart, exposed to a multi-megawatt neutrino beam that will be built at Fermilab. One of the two detectors will be installed several hundred meters downstream of the neutrino production point with the primary role of characterising the energy spectrum and composition of the beam as well as performing precision measurements of neutrino cross sections. For the design of this so-called near detector, the DUNE Collaboration is considering, among other technologies, a pressurized argon gas time projection chamber. Such a detector, thanks to its low density and low detection thresholds, would allow the detailed measurement in argon of nuclear effects at the neutrino interaction vertex, which are considered at present one of the most important sources of systematic uncertainty for neutrino oscillation measurements.

  9. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  10. Treatment of facial vascular lesions with an argon laser

    Science.gov (United States)

    Szymanczyk, Jacek; Golebiowska, Aleksandra; Michalska, I.

    1996-03-01

    Two-hundred-ninety-six patients with various vascular lesions of the face have been treated with argon laser LAK-1 in the Department of Dermatology Warsaw Medical Academy since April 1992. The diagnosis of the treated lesions was port-wine stains, multiple telangiectasiae and small, most often induced by trauma hemangioma cavernosum of the lip. Best results were achieved in the patients with small hemangiomas cavernosum of the lip and multiple telangiectasiae on the face. Cure rate in this group was 100%. In 112 port-wine stain cases fading of 50 - 75% comparing with the adjacent skin was achieved. With stress, the argon laser therapy is a method of choice for the treatment of hemangioma cavernosum, port-wine stains and multiple teleagiectasiae of the face.

  11. Development of cryogenic installations for large liquid argon neutrino detectors

    CERN Document Server

    Adamowski, M; Geynisman, M; Hentschel, S; Montanari, D; Nessi, M; Norris, B

    2015-01-01

    A proposal for a very large liquid argon (68,000 kg) based neutrino detector is being studied. To validate the design principles and the detector technology, and to gain experience in the development of the cryostats and the cryogenic systems needed for such large experiments, several smaller scale installations will be developed and implemented, at Fermilab and CERN. The cryogenic systems for these installations will be developed, constructed, installed and commissioned by an international engineering team. These installations shall bring the required cooling power under specific conditions to the experiments for the initial cool-down and the long term operation, and shall also guarantee the correct distribution of the cooling power within the cryostats to ensure a homogeneous temperature distribution within the cryostat itself. The cryogenic systems shall also include gaseous and liquid phase argon purification devices to be used to reach and maintain the very stringent purity requirements needed for these...

  12. Spectroscopy of Argon Excited in an Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Trabert, E

    2005-04-18

    Argon is one of the gases best investigated and most widely used in plasma discharge devices for a multitude of applications that range from wavelength reference standards to controlled fusion experiments. Reviewing atomic physics and spectroscopic problems in various ionization stages of Ar, the past use and future options of employing an electron beam ion trap (EBIT) for better and more complete Ar data in the x-ray, EUV and visible spectral ranges are discussed.

  13. Influence of argon pollution on the weld surface morphology

    OpenAIRE

    Krolczyk, G.M.; Nieslony, P.; Krolczyk, J.B.; I. Samardzic; Legutko, S.; S. Hloch; Barrans, Simon; Maruda, R.W.

    2015-01-01

    In this paper the surfaces of butt welded joints in steel tubes were analyzed using an optical 3D measurement system to determine the morphology and topographic parameters. It was established that pollution of the argon shield gas with oxygen did not influence the width of the heat-affected zone. However, the composition of the shield gas significantly influenced the surface asymmetry, Ssk, and its inclination Sku. The measurement of these parameters enabled the selection of a ...

  14. STATUS OF THE ATLAS LIQUID ARGON CALORIMETER AND ITS PERFORMANCE

    CERN Document Server

    Berillari, T; The ATLAS collaboration

    2011-01-01

    The liquid argon (LAr) calorimeters are used in ATLAS for all electromagnetic and for hadron calorimetry. The LAr calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic, hadronic and forward calorimeters. The latest status of the detector as well as problems and solutions addressed during the last years will be presented. Aspects of operation of a large detector over a long time period will be summarized and selected topics showing the performance of the detector will be shown.

  15. Thermal decomposition of lanthanum(III) butyrate in argon atmosphere

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Xiao, Tang;

    2013-01-01

    The thermal decomposition of La(C3H7CO2)3·xH2O (x≈0.82) was studied in argon during heating at 5K/min. After the loss of bound H2O, the anhydrous butyrate presents at 135°C a phase transition to a mesophase, which turns to an isotropic liquid at 180°C. The decomposition of the anhydrous butyrate ...

  16. Operational performance of a large liquid argon photon calorimeter

    International Nuclear Information System (INIS)

    We describe the performance of a large (0.9x1.4 m2) liquid argon photon calorimeter in high energy experiments at Fermilab. Resolutions for π0 and electron showers, obtained under data-taking conditions, are compared with electron-beam calibration results. Exceptional spatial and time resolutions have been achieved for isolated showers (sigmasub(x,y)0 data up to 180 GeV are presented. (orig.)

  17. Unified set of atomic transition probabilities for neutral argon

    OpenAIRE

    Wiese, W.; Brault, J.; Danzmann, K.; Helbig, V.; de Kock, M

    1989-01-01

    The atomic transition probabilities and radiative lifetimes of neutral argon have been the subject of numerous experiments and calculations, but the results exhibit many discrepancies and inconsistencies. We present a unified set of atomic transition probabilities, which is consistent with essentially all recent results, albeit sometimes only after critical reanalysis. The data consistency and scale confirmation has been achieved in two ways. (i) We have carried out some lifetime–branching-ra...

  18. Monte Carlo Simulation of Argon in Nano-Space

    Institute of Scientific and Technical Information of China (English)

    CHEN Min; YANG Chun; GUO Zeng-Yuan

    2000-01-01

    Monte Carlo simulations are performed to investigate the thermodynamic properties of argon confined in nano-scale cubes constructed of graphite walls. A remarkable depression of the system pressures is observed. The simulations reveal that the length-scale of the cube, the magnitude of the interaction between the fluid and the graphite wall and the density of the fluid exhibit reasonable effects on the thermodynamic property shifts of the luid.

  19. Two dimensional condensation of argon adsorbed on lamellar halides

    International Nuclear Information System (INIS)

    Lamellar halides such as NiCl2, FeCl2, NiBr2, MnBr2, MgBr2, CdBr2, CoI2, FeI2, MnI2, CaI2 and PbI2 were sublimed in a rapid stream of dry nitrogen. The adsorption of argon on such materials shows stepped isotherms which reveal two dimensional condensations. From sets of isotherms the Helmholtz free energy, the internal energy and the entropy of the successive layers are determined. From the entropy of the first layer the role of the potential relief of the adsorbent surface on the structure of the adsorbed layer may be determined while the Helmholtz free energy reveals how the ionic character of the adsorbent governs the attractive force of adsorption. The study of the second third and fourth layers shows that their growth follows quite a different behaviour depending on whether the Van der Waals diameter of argon is greater or smaller than the distance between adjacent anions on the crystal surface. A proposition is made to account for the difference in the critical temperatures of the first and second dense layers in terms of the vibrationnal state of their respective substrate. The occurence for the maximum critical temperature observed of corresponding to a triangular layer 3% more expanded than the (111) plane of solid argon is discussed

  20. A liquid argon scintillation veto for the Gerda experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Bare germanium detectors are operated in a cryostat with 65 m{sup 3} of liquid argon (LAr). To reach the aspired background index of ≤10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). A light instrumentation of LAr installed in the LArGe test facility has demonstrated that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. Based on these results, Gerda pursues several options for the light instrumentation, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Q{sub ββ} at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. The design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed, together with their expected performance from Monte Carlo simulations. In addition, the progress of development is reported, along with the design criteria for light instrumentation in Gerda.

  1. A liquid argon scintillation veto for the Gerda experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Bare germanium detectors are operated in a cryostat with 65 m3 of liquid argon (LAr). To reach the aspired background index of ≤10-3 cts/(keV.kg.yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). A light instrumentation of LAr installed in the LArGe test facility has demonstrated that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. Based on these results, Gerda pursues several options for the light instrumentation, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Qββ at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. The design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed, together with their expected performance from Monte Carlo simulations. In addition, the progress of development is reported, along with the design criteria for light instrumentation in Gerda.

  2. Space-charge effects in liquid argon ionization chambers

    Science.gov (United States)

    Rutherfoord, J. P.; Walker, R. B.

    2015-03-01

    We have uniformly irradiated liquid argon ionization chambers with betas from high-activity 90Sr sources. The radiation environment is similar to that in the liquid argon calorimeters which are part of the ATLAS detector installed at CERN's Large Hadron Collider (LHC). We measured the resulting ionization current over a wide range of applied potential for two different source activities and for three different chamber gaps. These studies provide operating experience at exceptionally high ionization rates. In particular they indicate a stability at the 0.1% level for these calorimeters over years of operation at the full LHC luminosity when operated in the normal mode at an electric field E = 1.0 kV / mm. We can operate these chambers in the normal mode or in the space-charge limited regime and thereby determine the transition point between the two. This transition point is parameterized by a positive argon ion mobility of μ+ = 0.08 ± 0.02mm2 / V s at a temperature of 88.0±0.5 K and at a pressure of 1.02±0.02 bar. In the space-charge limited regime the ionization currents are degraded and show signs of instability. At the highest electric fields in our study (6.7 kV/mm) the ionization current is still slowly rising with increasing electric field.

  3. ARAPUCA a new device for liquid argon scintillation light detection

    International Nuclear Information System (INIS)

    We present a totally innovative device for the detection of liquid argon scintillation light, that has been named ARAPUCA (Argon R and D Advanced Program at UniCAmp). It is composed of a passive light collector and of active devices. The latters are standard SiPMs that operate at liquid argon temperature, while the passive collector is based on a new technology, never explored in this field before. It is a photon trap, that allows to collect light with extremely high efficiency. The total detection efficiency of the device can be tuned by modifying the ratio between the area of the active devices (SiPM) and the area of the optical window. For example, it will allow to reach a detection efficiency at the level of 1% on a surface of 50 × 50 cm2 with an active coverage of 2 × 2 cm2 (two/three large area SiPM). It is also a cheap device, since the major part of its cost is represented by the active devices. For these reason this appears to be the ideal device for scintillation light detection in large Time Projection Chambers. With appropriate modifications it can be used also in next generation Dark Matter detectors

  4. Isotopic fractionation of argon during stepwise release from shungite

    International Nuclear Information System (INIS)

    In previous attempts to determine the 40Ar/36Ar ratio in the ancient atmosphere, the only direct measurement yielding a value below the atmospheric value of today is for argon released at low temperatures from a pre-Cambrian shungite, an amorphous carbon mineral The present work confirms a low value for 40Ar/36Ar in gas released from a type I shungite at low temperatures. But quantitative scrutiny of the accompanying 38AR/36Ar ratios and the enhanced ratio of 40Ar/36Ar for the fractions released at high temperatures shows convincingly that the effect seen here is an artifact of the stepwise heating and the argon diffusion mobilized thereby. The low 40Ar/36Ar previously obtained is very likely from the same cause rather than reflecting the isotopic composition of the pre-Cambrian atmosphere. The vitreous character of and the sharp, conchoidal fractures seen in the specimens of type I shungite suggest that the substance may exhibit simple volume diffusion over macroscopic dimensions as glasses do. If so, the diffusion parameters (D infinitely = 3 x 10-4 cm2/s and E = 11 kcal/mole) obtained from the data imply rapid exchange with the atmosphere for any argon initially trapped in centimenter-thick veins of the material. (orig.)

  5. Isotopic fractionation of argon during stepwise release from shungite

    Science.gov (United States)

    Rison, W.

    1980-05-01

    It is noted that in previous attempts to determine the Ar-40/Ar-36 ratio in the ancient atmosphere, the only direct measurement yielding a value below the atmospheric value of today is for argon released at low temperatures from a pre-Cambrian shungite. In the present work, a low value for Ar-40/Ar-36 in gas released from a type I shungite at low temperatures is confirmed. Attention is given to a study of the accompanying Ar-38/Ar-36 ratios and the enhanced ratio of Ar-40/Ar-36 for the fractions released at high temperatures which shows that the effect observed is a result of the stepwise heating and the argon diffusion mobilized thereby. It is suggested that the low Ar-40/Ar-36 obtained in the past is from the same source rather than reflecting the isotropic composition of the pre-Cambrian atmosphere, and that the type I shungite may exhibit simple volume diffusion over macroscopic dimensions as glasses do. It is concluded that if this is so, the diffusion parameters obtained from the data would imply rapid exchange with the atmosphere for any argon initially trapped in the veins of the material.

  6. Tin LPP plasma control in the argon cusp source

    Science.gov (United States)

    McGeoch, Malcolm W.

    2016-03-01

    The argon cusp plasma has been introduced [1,2] for 500W class tin LPP exhaust control in view of its high power handling, predicted low tin back-scatter from a beam dump, and avoidance of hydrogen usage. The physics of tin ion control by a plasma is first discussed. Experimentally, cusp stability and exhaust disc geometry have previously been proved at full scale [2], the equivalent of 300W-500W usable EUV. Here we verify operation of the plasma barrier that maintains a high argon density next to the collector, for its protection, and a low density in the long path toward the intermediate focus, for efficiency. A pressure differential of 2Pa has been demonstrated in initial work. Other aspects of tin LPP plasma control by the cusp have now been demonstrated using tin ions from a low Hz 130mJ CO2 laser pulse onto a solid tin surface at the cusp center. Plasma is rejected at the design to match a specified exhaust power is discussed. In view of this work, argon cusp exhaust control appears to be very promising for 500W class tin LPP sources.

  7. Bacteria Inactivation Using DBD Plasma Jet in Atmospheric Pressure Argon

    Institute of Scientific and Technical Information of China (English)

    XU Guimin; ZHANG Guanjun; SHI Xingmin; MA Yue; WANG Ning; LI Yuan

    2009-01-01

    A coaxial dielectric barrier discharge plasma jet Was designed,which can be operated in atmospheric pressure argon under an intermediate frequency sinusoidal resonant power supply,and an atmospheric pressure glow-like discharge Was achieved.Two kinds of typical bacteria,i.e.,the Staphylococcus aureus(S.aurens)and Escherichia coil(E.coil),were employed to study the bacterial inactivation mechanism by means of the non-thermal plasma.The killing log value (KLV)of S.aureus reached up to 5.38 with a treatment time of 90 s and that of E.coil up to 5.36 with 60 s,respectively.According to the argon emission spectra of the plasma jet and the scanning electron microscope (SEM) images of the two bacteria before and after the plasma treatment.it is concluded that the reactive species in the argon plasma played a major role in the bacterial inactivation,while the heat,electric field and UV photons had little effect.

  8. Metal clusters on supported argon layers; Metallcluster auf dielektrischen Substraten

    Energy Technology Data Exchange (ETDEWEB)

    Faber, Bernhard

    2011-10-21

    The deposition of small sodium clusters on supported Ar(001)-surfaces is simulated. Theoretical description is achieved by a hierarchical model consisting of time-dependent DFT and molecular dynamics. The valence electrons of the sodium atoms are considered by Kohn-Sham-Scheme with self interaction correction. The interaction of argon atoms and sodium ions is described by atom-atom potentials whereas the coupling to the QM electrons is done by local pseudo-potentials. A decisive part of the model is the dynamical polarizability of the rare-gas atoms. The optional metal support is considered by the method of image charges. The influence of the forces caused by image charges and the influence of the number of argon monolayers on structure, optical response and deposition dynamics of Na{sub 6} and Na{sub 8} is investigated. There is very little influence on cluster structure and only a small shift of the cluster perpendicular to the surface. Concerning optical response the position of the Mie plasmon peak stays robust whereas the details of spectral fragmentation react very sensitively to changes. The forces caused by image charges of the metal support play only a little role with the dynamics of deposition while the thickness of the argon surface strongly influences the dissipation. (orig.)

  9. K-Ar age of young volcanic rocks and excess argon--Binary mixing model and quantitative study of excess argon effect

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A binary mixing model for excess argon is suggested in the note. According to this model and the data of excess argon component obtained in our experiment , a quantitative study of the effect of excess argon on real K-Ar age of young volcanic rocks is done. The result indicates that the effect of 5% excess argon component in samples on K-Ar age of the samples more than 2 Ma is less than 7.36% and can lead K-Ar age of 0.5 Ma samples to increase by 32.4%, while 1% excess argon component leads K-Ar age of 0.5 Ma samples to increase by 6.26%. Therefore, when pre-processed excess argon component is ≤1%, K-Ar age of the samples more than 0.5 Ma should be credible. On this basis we suggest a principal opinion for evaluation of previous K-Ar dating results and propose that the matrix is used to determine K-Ar age of young volcanic rocks. For the samples less than 0.2 Ma, in the case of high excess argon content, even if only 1% excess argon component exists in their matrix, it can also greatly affect their K-A age. Thus it must be careful to treat the dating result.

  10. Roles of argon seeding in energy confinement and pedestal structure in JT-60U

    International Nuclear Information System (INIS)

    The mechanism of improving energy confinement with argon seeding at high density has been investigated in JT-60U. Better confinement is sustained at high density by argon seeding accompanied by higher core and pedestal temperatures. The electron density profiles become flatter with increasing density in conventional H-mode plasmas, whereas peaked density profiles are maintained with argon seeding. Density peaking and dilution effects lower the pedestal density at a given averaged density. The pedestal density in the argon seeded plasmas, which is lower than that in plasmas with deuterium puff, enables the pedestal temperature to be higher, whereas the increase in the pedestal pressure with argon seeding is small. High pedestal temperature is a boundary condition for high core temperature through profile stiffness, which leads to better confinement with argon seeding. The density peaking is a key factor of sustaining better confinement in argon seeded H-mode plasmas. The radiative loss power density is predominantly enhanced in the edge region by argon puff. The role of argon seeding in the pedestal characteristics has also been examined. The pedestal width becomes larger continuously with edge collisionality, but is nearly independent of the presence of argon seeding. (paper)

  11. Argon-41 production and evolution at the Oregon State University TRIGA Reactor (OSTR)

    International Nuclear Information System (INIS)

    In this study, argon-41 concentrations were measured at various locations within the reactor facility to assess the accuracy of models used to predict argon-41 evolution from the reactor tank, and to determine the relationship between argon gas evolution from the tank and subsequent argon-41 concentrations throughout the reactor room. In particular, argon-41 was measured directly above the reactor tank with the reactor tank lids closed, at other accessible locations on the reactor top with the tank lids both closed and open, and at several locations on the first floor of the reactor room. These measured concentrations were then compared to values calculated using a modified argon-41 production and evolution model for TRIGA reactor tanks and ventilation values applicable to the OSTR facility. The modified model was based in part on earlier TRIGA models for argon-41 production and release, but added features which improved the agreement between predicted and measured values. The approximate dose equivalent rate due to the presence of argon-41 in reactor room air was calculated for several different locations inside the OSTR facility. These dose rates were determined using the argon-41 concentration measured at each specific location, and were subsequently converted to a predicted quarterly dose equivalent for each location based on the reactor's operating history. The predicted quarterly dose equivalent values were then compared to quarterly doses measured by film badges deployed as dose-integrating area radiation monitors at the locations of interest. The results indicate that the modified production and evolution model is able to predict argon-41 concentrations to within a factor of ten when compared to the measured data. Quarterly dose equivalents calculated from the measured argon-41 concentrations and the reactor's operating history seemed consistent with results obtained from the integrating area radiation monitors. Given the argon-41 concentrations measured

  12. The effects of argon in the bioenergetics of the hamster and the rat

    Science.gov (United States)

    Tempel, G. E.; Musacchia, X. J.

    1974-01-01

    Oxygen consumption was examined in hamsters and rats exposed to normoxic mixtures of argon at 1 atm. In fasted and nonfasted animals, no marked change in O2 utilization was detectable at 22 C. However, at 7 C a significant decrease in oxygen consumption was observed where the animals were exposed in argon. The data are interpreted in terms of the greater thermal conductivity of nitrogen. The study was prompted by conflicting reports on the metabolic effects of argon and helium.

  13. Argon Laser Photoablation for Treating Benign Pigmented Conjunctival Nevi

    Science.gov (United States)

    Alsharif, Abdulrahman M.; Al-Gehedan, Saeed M.; Alasbali, Tariq; Alkuraya, Hisham S.; Lotfy, Nancy M.; Khandekar, Rajiv

    2016-01-01

    Purpose: To evaluate the outcomes of argon laser photoablation of benign conjunctival pigmented nevi with different clinical presentations. Patients and Methods: This interventional case series was conducted between July 2014 and January 2015. Patients presenting with benign conjunctival nevi were included. Data were collected on the clinical features at presentation, argon laser photoablation, and follow-up at 8 and 24 weeks. Postoperative photography allowed recording of the success of each case and the overall success rate. Complete removal of conjunctival pigments was considered an absolute success. Partial pigmentation requiring repeat laser treatment was considered a qualified success. Results: There were 14 eyes (four right eyes and ten left eyes) with benign pigmented conjunctival nevi. There were three males and eight females in the study sample. The median age was 36 (25% percentile: 26 years). Three patients had bilateral lesions. The nevi were located temporally in nine eyes, nasally in three eyes, and on the inferior bulbar conjunctiva in two eyes. The mean horizontal and vertical diameters of nevi were 5 ± 2 mm and 4 ± 2.7 mm, respectively. The mean follow-up period was 5 months. Following laser treatment, no eyes had subconjunctival hemorrhage, infection, scarring, neovascularization, recurrence, or corneal damage. The absolute success rate of laser ablation was 79%. Three eyes with elevated nevi had one to three sessions of laser ablation resulting in a qualified success rate of 100%. Conclusions: Argon laser ablation was a safe and effective treatment for the treatment of selective benign pigmented conjunctival nevi in Arab patients. PMID:27555708

  14. The abundances of neon, sulfur, and argon in planetary nebulae

    Science.gov (United States)

    Beck, S. C.; Lacy, J. H.; Townes, C. H.; Aller, L. H.; Geballe, T. R.; Baas, F.

    1981-01-01

    New infrared observations of Ne II, Ar III, and S IV are used in optical observations of other ionization states of the considered elements to evaluate the abundances of neon, argon, and sulfur in 18 planetary nebulae. Attention is also given to one or more of the infrared lines in 18 other nebulae. It is pointed out that S IV was detected in approximately 90% of the observed objects, while Ar III was found in about 80%, and Ne II in roughly one-third. It is noted that optical observations typically include only a limited region of the nebula, while the infrared measurements frequently involve integration over the entire nebular image.

  15. Ionization coefficients for argon in a micro-discharge

    International Nuclear Information System (INIS)

    Ionization coefficients are measured for electrons in a dc micro-discharge in argon from optical emission profiles. The micro-discharge is operated in the Townsend regime between two parallel-plate electrodes. Axial profiles of emission are obtained with sufficient resolution to provide spatial ionization coefficients. The measured coefficients agree very well with the data obtained from other sources, indicating the operation of the discharge in the Townsend regime and also that Townsend mechanisms do not need extension to describe such discharges. (paper)

  16. Kinetic modeling of the Townsend breakdown in argon

    Science.gov (United States)

    Macheret, S. O.; Shneider, M. N.

    2013-10-01

    Kinetic modeling of the Townsend breakdown in argon was performed in the "forward-back" approximation. The kinetic model was found to adequately describe the left branch of the Paschen curve, and the important role of ionization by fast ions and atoms near the cathode, as well as the increase in secondary emission coefficient in strong electric fields described in the literature, was confirmed. The modeling also showed that the electron energy distribution function develops a beam of high-energy electrons and that the runaway effect, i.e., the monotonic increase of the mean electron energy with the distance from the cathode, occurs at the left branch of the Paschen curve.

  17. Ionization coefficients for argon in a micro-discharge

    Science.gov (United States)

    Kuschel, Thomas; Stefanović, Ilija; Malović, Gordana; Marić, Dragana; Petrović, Zoran Lj

    2013-08-01

    Ionization coefficients are measured for electrons in a dc micro-discharge in argon from optical emission profiles. The micro-discharge is operated in the Townsend regime between two parallel-plate electrodes. Axial profiles of emission are obtained with sufficient resolution to provide spatial ionization coefficients. The measured coefficients agree very well with the data obtained from other sources, indicating the operation of the discharge in the Townsend regime and also that Townsend mechanisms do not need extension to describe such discharges.

  18. Diffusion coefficient of metal vapours into rare gases. Mercury - argon

    International Nuclear Information System (INIS)

    The source information is present as well as the results of analysis and integration of data on mutual diffusion coefficient (MDC) of mercury - argon mixture at Hg concentration → 0 in 300-2500 K temperature range. Reference data on MDC for metal - inert gas binary mixtures obtained on the base of complex analysis of various information, as it exemplified by Hg-Ar pair, can be used as a part of metrological support at calibration of devices for determination MDC of gas - metal vapors

  19. Electron drift velocity in argon-methane mixture

    International Nuclear Information System (INIS)

    Described are the results of a series of measurements of electron drift velocity taken with samples of chemically pure grade gas mixture of Ar-10% CH4 (N2222O<2 ppm). The measured drift velocity is plotted as a function of the ratio of electric field to pressure in the range from 0.05 to 0.8 V/cmxtorr. The measurements are reproducible only to within 4%. The results of numerical calculations employing the well-established argon elastic and methane elastic and inelastic cross sections are also included. The disagreement from the present experimental results, and from those obtained elsewhere, is rather puzzling

  20. High intensity, argon ion laser-jet photochemistry

    Science.gov (United States)

    Wilson, R. Marshall; Schnapp, Karlyn A.; Hannemann, Klaus; Ho, Douglas M.; Memarian, Hamid R.; Azadnia, Ardeshir; Pinhas, Allan R.; Figley, Timothy M.

    A new technique for the study of high intensity solution photochemistry has been developed. With this laser-jet technique, a high velocity microjet is irradiated with the focussed output of an argon ion laser. Under these extremely high intensity conditions, photochemically generated transient species with suitable absorption properties are excited further and produce relatively large amounts of photoproducts which are not observed under low intensity conditions. The application of this laser-jet technique in the study of the photochemistry of radicals, biradicals, photoenols and the higher excited states of carbonyl and polycyclic aromatic compounds is described.

  1. Optical fiber read-out for liquid argon scintillation light

    CERN Document Server

    Csáthy, J Janicskó; Kratz, J; Schönert, S; Wiesinger, Ch

    2016-01-01

    In this paper we describe the performance of a light detector for Ar scintillation light made of wavelength-shifting (WLS) fibers connected to Silicon-Photomultipliers (SiPM). The setup was conceived to be used as anti-Compton veto for high purity germanium (HPGe) detectors operated directly in liquid Argon (LAr). Background suppression efficiencies for different radioactive sources were measured in a test cryostat with about 800 kg LAr. This work was part of the R\\&D effort for the GERDA experiment.

  2. Study of a novel electromagnetic liquid argon calorimeter TGT

    International Nuclear Information System (INIS)

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a test beam exposure. 15 refs., 16 figs., 2 tabs

  3. Activation of copper by nitrogen and argon beams

    Energy Technology Data Exchange (ETDEWEB)

    Chetvertkova, Vera [IAP, Goethe-University, Frankfurt am Main (Germany); GSI Darmstadt (Germany); Mustafin, Edil; Strasik, Ivan [GSI Darmstadt (Germany); Belousov, Anton [TU Darmstadt (Germany); Latysheva, Ludmila; Sobolevsky, Nikolai [INR RAS, Moscow (Russian Federation); Ratzinger, Ulrich [IAP, Goethe-University, Frankfurt am Main (Germany)

    2012-07-01

    Monte Carlo transport codes are widely used for various purposes in nuclear physics, radiation protection, medical applications, accelerator design etc. Code verification by experiments is needed to be sure that the codes give accurate results. New data on the activation of copper by a nitrogen beam of 500 MeV/u is presented and compared with FLUKA and SHIELD simulation results. The activation of copper by a nitrogen beam is compared to activation by an argon beam and respective simulations. This gives a chance to see the accuracy of the codes at different projectile masses. Correspondences and discrepancies of calculations and experiments are discussed.

  4. Study of a Novel Concept for a Liquid Argon Calorimeter \

    CERN Multimedia

    2002-01-01

    % RD33 \\\\ \\\\ The development of a fast, highly granular and compact electromagnetic liquid argon calorimeter prototype is proposed as a generic R\\&D project for a novel concept of calorimetry in proton-proton and electron-positron collider detectors: the $^{\\prime$Thin Gap Turbine$^{\\prime}$ (TGT). The TGT calorimeter has a modular construction, is flexible in its longitudinal and transverse granularity, and offers a uniform energy response and resolution, independent of the production angle of incident particles. An important aspect of the project is the development of fast, radiation-hard front-end electronics which is operating in the cold.

  5. Activation of aluminum by argon: Experimental study and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Chetvertkova, V., E-mail: v.chetvertkova@gsi.de [GSI Helmholtzzentrum fuer Schwerionenforschung Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany); J. W. Goethe-University Frankfurt am Main, IAP, Max-von-Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Strasik, I. [GSI Helmholtzzentrum fuer Schwerionenforschung Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany); J. W. Goethe-University Frankfurt am Main, IAP, Max-von-Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Belousov, A. [GSI Helmholtzzentrum fuer Schwerionenforschung Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany); Iwase, H. [High Energy Accelerator Research Organization, KEK, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Mokhov, N. [Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510 (United States); Mustafin, E. [GSI Helmholtzzentrum fuer Schwerionenforschung Darmstadt, Planckstrasse 1, 64291 Darmstadt (Germany); Latysheva, L. [Institute for Nuclear Research RAS, 117312 Moscow (Russian Federation); Pavlovic, M. [FEI STU, Ilkovicova 3, 812 19 Bratislava (Slovakia); Ratzinger, U. [J. W. Goethe-University Frankfurt am Main, IAP, Max-von-Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Sobolevsky, N. [Institute for Nuclear Research RAS, 117312 Moscow (Russian Federation)

    2011-06-15

    The paper presents the results of irradiation of aluminum targets by 430 and 500 MeV/u argon beams. Gamma-spectra were measured after the end of the irradiation in order to identify the induced nuclides as well as to determine their residual activity depth-profiles. The results of this experiment are compared with Monte Carlo simulations by FLUKA, GEANT4, MARS, PHITS and SHIELD-A codes. In case of a thin target, the agreement between the experiment and simulations is satisfactory, while in case of a thick target, some discrepancies are observed.

  6. Laser-induced vibrational dynamics of ozone in solid argon

    DEFF Research Database (Denmark)

    Hansen, Flemming Yssing; Amstrup, B.; Henriksen, Niels Engholm

    1997-01-01

    We consider the vibrational dynamics, induced by an intense infrared laser pulse, in an ozone molecule with isotopic substitution, that is, (OOO)-O-16-O-16-O-18 and compare the dynamics in the gas phase and in solid ar on. not perturbed by argon on a time-scale of a few picoseconds and selective...... bond-breaking in the molecule should be possible following the same laser control scheme as suggested in the gas phase. (C) 1997 Elsevier Science B.V....

  7. Electron transport in argon in crossed electric and magnetic fields

    Science.gov (United States)

    Ness; Makabe

    2000-09-01

    An investigation of electron transport in argon in the presence of crossed electric and magnetic fields is carried out over a wide range of values of electric and magnetic field strengths. Values of mean energy, ionization rate, drift velocity, and diffusion tensor are reported here. Two unexpected phenomena arise; for certain values of electric and magnetic field we find regions where the swarm mean energy decreases with increasing electric fields for a fixed magnetic field and regions where swarm mean energy increases with increasing magnetic field for a fixed electric field. PMID:11088933

  8. LArIAT: Liquid Argon In A Testbeam

    CERN Document Server

    Cavanna, F; Raaf, J; Rebel, B

    2014-01-01

    Liquid Argon Time Projection Chambers (LArTPCs) are ideal detectors for precision neutrino physics. These detectors, when located deep underground, can also be used for measurements of proton decay, and astrophysical neutrinos. The technology must be completely developed, up to very large mass scales, and fully mastered to construct and operate these detectors for this physics program. As part of an integrated plan of developing these detectors, accurate measurements in LArTPC of known particle species in the relevant energy ranges are now deemed as necessary. The LArIAT program aims to directly achieve these goals by deploying LArTPC detectors in a dedicated calibration test beam line at Fermilab. The set of measurements envisaged here are significant for both the short-baseline (SBN) and long-baseline (LBN) neutrino oscillation programs in the US, starting with MicroBooNE in the near term and with the adjoint near and far liquid argon detectors in the Booster beam line at Fermilab envisioned in the mid-term...

  9. A liquid argon scintillation veto for the GERDA experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10-3 cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  10. A liquid argon scintillation veto for the GERDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10{sup -3} cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  11. Some transport properties in plasmas containing argon and fluorine

    Directory of Open Access Journals (Sweden)

    Novaković R.N.V.

    2003-01-01

    Full Text Available In this paper some results of numerical evaluation of transport coefficients in plasmas in the mixtures of argon and fluorine are presented. These transport characteristics are given in the function of the temperature for low pressures ranging from 0,1 kPa to 1,0 kPa and for low temperatures between 500 K and 5 000 K in argon plasmas with 20% and 30% of the fluorine added. It is assumed that the system is kept under constant pressure and that a corresponding state of local thermodynamical equilibrium (LTE is attained in it. The equilibrium plasma composition, necessary for the evaluations, was determined on the ground of the Saha equations for ionization processes and the law of mass action for the thermal dissociation of F2, combined with the charge conservation relation and the assumption that the pressure remained constant in the course of temperature variations. The ionization energy lowering, required in conjunction with the Saha equations, was obtained with the aid of a modified expression for the plasma Debye radius proposed previously. A previously derived expression for the modified Debye radius, offering the possibility to treat the plasmas considered as weakly non-ideal in the whole temperature range, is used. The cut-off at the Landau length rather than of the smallest of ionic radii is introduced. This alteration in the evaluation procedure brings different considerable changes in the final numerical results for the all relevant quantities.

  12. Compilation of electron collision excitation cross sections for neutro argon

    International Nuclear Information System (INIS)

    The present work presents a compilation and critical analysis of the available data on electron collision excitation cross sections for neutral Argon levels. This study includes: 1.- A detailed description in intermediate coupling for all the levels belonging the 20 configurations 3p''5 ns(n=4 to 12), np(n=4 to 8) and nd(n=3 to 8) of neutral Argon. 2.- Calculation of the electron collision excitation cross sections in Born and Born-Oppenheimer-Ochkur approximations for all the levels in the 14 configurations 3p''5 ns(n=4 to 7), np(n=4 to 7) and nd(n=3 to 8). 3.- Comparison and discussion of the compiled data. These are the experimental and theoretical values available from the literature, and those from this work. 4.- Analysis of the regularities and systematic behaviors in order to determine which values can be considered more reliable. It is show that the concept of one electron cross section results quite useful for this purpose. In some cases it has been possible to obtain in this way approximate analytical expressions interpolating the experimental data. 5.- All the experimental and theoretical values studied are graphically presented and compared. 6.- The last part of the work includes a listing of several general purpose programs for Atomic Physics calculations developed for this work. (Author)

  13. Elastic properties of liquid and solid argon in nanopores.

    Science.gov (United States)

    Schappert, Klaus; Pelster, Rolf

    2013-10-16

    We have measured sorption isotherms and determined the intrinsic longitudinal elastic modulus β(Ar,ads) of nanoconfined material via ultrasonic measurements combined with a special effective medium analysis. In the liquid regime the adsorbate only contributes to the measured effective properties when the pores are completely filled and the modulus is bulklike. At partial fillings its contribution is cancelled out by the high compressibility of the vapour phase. In contrast, at lower temperatures frozen argon as well as underlying liquid surface layers cause a linear increase of the effective longitudinal modulus upon filling. During sorption the contribution of the liquid surface layers near the pore wall β(Ar,surf) increases with the thickness of the solid layers reaching the bulk value β(Ar,liquid) only in the limit of complete pore filling. We interpret this effect as due to the gradual stiffening of the solid argon membrane. The measurements and their analysis show that longitudinal ultrasonic waves are well suited to the study of the elastic properties and liquid-solid phase transitions in porous systems. This method should also help to detect the influence of nanoconfinement on elastic properties in further research. PMID:24057946

  14. Local effects of ECRH on argon transport at ASDEX upgrade

    International Nuclear Information System (INIS)

    Future deuterium-tritium magnetically confined fusion power plants will most probably rely an high-Z Plasma Facing Components (PFCs) such as tungsten. This choice is determined by the necessity of low erosion of the first wall materials (to guarantee a long lifetime of the wall components) and by the need to avoid the too high tritium wall retention of typical carbon based PFCs. The experience gathered at the ASDEX Upgrade (AUG) tokamak has demonstrated the possibility of reliable and high performance plasma operation with a full tungsten-coated first wall. The observed accumulation of tungsten which can lead to excessive radiation losses is mitigated with the use of Electron Cyclotron Resonance Heating (ECRH). Although this impurity control method is routinely performed at AUG, the underlying physics principles are still not clear. This thesis aims an providing further knowledge an the effects of ECRH an the transport of impurities inside the core plasma. The transport of argon has been therefore investigated in-depth in purely ECR heated L-mode (low-confinement) discharges. Studies an impurity transport in centrally ECR heated nitrogen-seeded H-mode (high-confinement) discharges have also been performed. To this scope, a new crystal X-ray spectrometer of the Johann type has been installed an AUG for argon concentration and ion temperature measurements. New methods for the experimental determination of the total argon density through the integrated use of this diagnostic and of the Soft X-Ray (SXR) diode arrays have been developed. This gives the possibility of evaluating the full profiles of the argon transport coefficients from the linear flux-gradient dependency of local argon density. In comparison to classical χ2-minimization methods, the approach proposed here delivers transport coefficients intrinsically independent of the modelling of periodic relaxation mechanisms such as those Lied to sawtooth MHD (Magneto-Hydro-Dynamic) activity. Moreover, the good

  15. Ful distil ation argon producing crud argon column on operating experience%全精馏制氩粗氩塔操作经验浅谈

    Institute of Scientific and Technical Information of China (English)

    马光显

    2015-01-01

    This paper briefly introduces the ful distil ation argon recovery process in the crude argon column in air separation system of cooling,heating and put some matters needing attention in use.%简要介绍了全精馏制氩过程中粗氩塔在空分系统降温、升温及投用中的一些注意事项。

  16. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    Science.gov (United States)

    Sun, Wen-Ting; Li, Guo; Li, He-Ping; Bao, Cheng-Yu; Wang, Hua-Bo; Zeng, Shi; Gao, Xing; Luo, Hui-Ying

    2007-06-01

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images.

  17. First measurements with ARGONTUBE, a 5 m long drift Liquid Argon TPC

    International Nuclear Information System (INIS)

    The Liquid Argon Time Projection Chamber (LAr TPC) technique is a promising technology for future neutrino detectors. At LHEP of the University of Bern (Switzerland), an R and D program towards large detectors are on-going. The main goal is to show the feasibility of long drift paths over many meters. Therefore, a liquid Argon TPC with 5 m of drift distance was constructed. Many other aspects of the liquid Argon TPC technology are also investigated, such as a new device to generate high voltage in liquid Argon (Greinacher circuit), a recirculation filtering system and the multi-photon ionization of liquid Argon with a UV laser. Two detectors are built: a medium size prototype for specific detector technology studies, and ARGONTUBE, a 5 m long device

  18. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    International Nuclear Information System (INIS)

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images

  19. First measurement of the ionization yield of nuclear recoils in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, T. [Univ. of California, Berkeley, CA (United States). Dept. of Nuclear Engineering; Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Sangiorgio, Samuele [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Bernstein, A. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Foxe, Michael P. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Pennsylvania State Univ., University Park, PA (United States). Dept. of Mechanical and Nuclear Engineering; Hagmann, Chris [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Jovanovic, Igor [Pennsylvania State Univ., University Park, PA (United States). Dept. of Mechanical and Nuclear Engineering; Kazkaz, K. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Mozin, Vladimir V. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Norman, E. B. [Univ. of California, Berkeley, CA (United States). Dept. of Nuclear Engineering; Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Pereverzev, S. V. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Rebassoo, Finn O. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Sorensen, Peter F. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)

    2014-05-01

    Liquid phase argon has long been used as a target medium for particle detection via scintillation light. Recently there has been considerable interest in direct detection of both hypothetical darkmatter particles and coherent elastic neutrino nucleus scattering. These as-yet unobserved neutral particle interactions are expected to result in a recoiling argon atom O(keV), generally referred to in the literature as a nuclear recoil. This prompts the question of the available electromagnetic signal in a liquid argon detector. In this Letter we report the first measurement of the ionization yield (Qy), detected electrons per unit energy, resulting from nuclear recoils in liquid argon, measured at 6.7 keV. This is also the lowest energy measurement of nuclear recoils in liquid argon.

  20. Management of Liver Cancer Argon-helium Knife Therapy with Functional Computer Tomography Perfusion Imaging.

    Science.gov (United States)

    Wang, Hongbo; Shu, Shengjie; Li, Jinping; Jiang, Huijie

    2016-02-01

    The objective of this study was to observe the change in blood perfusion of liver cancer following argon-helium knife treatment with functional computer tomography perfusion imaging. Twenty-seven patients with primary liver cancer treated with argon-helium knife and were included in this study. Plain computer tomography (CT) and computer tomography perfusion (CTP) imaging were conducted in all patients before and after treatment. Perfusion parameters including blood flows, blood volume, hepatic artery perfusion fraction, hepatic artery perfusion, and hepatic portal venous perfusion were used for evaluating therapeutic effect. All parameters in liver cancer were significantly decreased after argon-helium knife treatment (p liver tissue, but other parameters kept constant. CT perfusion imaging is able to detect decrease in blood perfusion of liver cancer post-argon-helium knife therapy. Therefore, CTP imaging would play an important role for liver cancer management followed argon-helium knife therapy.

  1. Development of membrane cryostats for large liquid argon neutrino detectors

    CERN Document Server

    Montanari, D; Gendotti, A; Geynisman, M; Hentschel, S; Loew, T; Mladenov, D; Montanari, C; Murphy, S; Nessi, M; Norris, B; Noto, F; Rubbia, A; Sharma, R; Smargianaki, D; Stewart, J; Vignoli, C; Wilson, P; Wu, S

    2015-01-01

    A new collaboration is being formed to develop a multi-kiloton Long-Baseline neutrino experiment that will be located at the Surf Underground Research Facility (SURF) in Lead, SD. In the present design, the detector will be located inside cryostats filled with 68,400 ton of ultrapure liquid argon (less than 100 parts per trillion of oxygen equivalent contamination). To qualify the membrane technology for future very large-scale and underground implementations, a strong prototyping effort is ongoing: several smaller detectors of growing size with associated cryostats and cryogenic systems will be designed and built at Fermilab and CERN. They will take physics data and test different detector elements, filtration systems, design options and installation procedures. In addition, a 35 ton prototype is already operational at Fermilab and will take data with single-phase detector in early 2016. After the prototyping phase, the multi-kton detector will be constructed. After commissioning, it will detect and study ne...

  2. Fluorescence Spectrum of SiO in an Argon Matrix

    Science.gov (United States)

    Scullman, R.; Hormes, J.; Schroeder, W.; Wiggenhauser, H.

    1987-04-01

    Fluorescence from SiO matrix isolated in argon has been investigated in the wavelength region 120-300 nm. Fluorescence emission spectra from the valence states, A1Π, E1Σ+ and G1Π, revealed that nearly all radiation comes from one channel at 305 nm, which was analysed as originating from the b3Π-X1Σ+ transition. Contrary to the A1Π and G1Π states, the E1Σ+ state also decays radiatively, although weakly, through two other channels situated in the vicinity of 305 nm. These two channels were believed to originate from the a3Σ+-X1Σ+ and e3Σ--X1Σ+ transitions.

  3. Electron Neutrino Classification in Liquid Argon Time Projection Chamber Detector

    CERN Document Server

    Płoński, Piotr; Sulej, Robert; Zaremba, Krzysztof

    2015-01-01

    Neutrinos are one of the least known elementary particles. The detection of neutrinos is an extremely difficult task since they are affected only by weak sub-atomic force or gravity. Therefore large detectors are constructed to reveal neutrino's properties. Among them the Liquid Argon Time Projection Chamber (LAr-TPC) detectors provide excellent imaging and particle identification ability for studying neutrinos. The computerized methods for automatic reconstruction and identification of particles are needed to fully exploit the potential of the LAr-TPC technique. Herein, the novel method for electron neutrino classification is presented. The method constructs a feature descriptor from images of observed event. It characterizes the signal distribution propagated from vertex of interest, where the particle interacts with the detector medium. The classifier is learned with a constructed feature descriptor to decide whether the images represent the electron neutrino or cascade produced by photons. The proposed ap...

  4. Large area liquid argon detectors for interrogation systems

    Energy Technology Data Exchange (ETDEWEB)

    Gary, Charles; Kane, Steve; Firestone, Murray I.; Smith, Gregory [Adelphi Technology LLC, Purdue Technology Center, 5225 Exploration Drive, Indianapolis, IN 46241 (United States); Gozani, Tsahi; Brown, Craig; Kwong, John; King, Michael J. [Rapiscan Laboratories, 520 Almanor Avenue, Sunnyvale, CA 94085 (United States); Nikkel, James A.; McKinsey, Dan [Physics Department, Yale University, New Haven, CT 06520 (United States)

    2013-04-19

    Measurements of the efficiency, pulse shape, and energy and time resolution of liquid argon (LAr) detectors are presented. Liquefied noble gas-based (LNbG) detectors have been developed for the detection of dark matter and neutrinoless double-beta decay. However, the same qualities that make LNbG detectors ideal for these applications, namely their size, cost, efficiency, pulse shape discrimination and resolution, make them promising for portal screening and the detection of Special Nuclear Materials (SNM). Two 18-liter prototype detectors were designed, fabricated, and tested, one with pure LAr and the other doped with liquid Xe (LArXe). The LArXe detector presented the better time and energy resolution of 3.3 ns and 20% at 662 KeV, respectively. The total efficiency of the detector was measured to be 35% with 4.5% of the total photons detected in the photopeak.

  5. Argon plasma coagulation for treatment of hemorrhagic radiation gastroduodenitis

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Shu-Ji; Aoyama, Nobuo; Shirasaka, Daisuke; Inoue, Takashi; Kuroda, Kohei; Ebara, Shigeyuki; Tamura, Takao; Miyamoto, Masaki; Kasuga, Masato [Kobe Univ. (Japan). Graduate School of Medicine

    2002-01-01

    A 79-year-old man who had received radiotherapy for portal vein thrombosis due to hepatocellular carcinoma (HCC) 5 months earlier, showed progressive anemia and melena. Endoscopy on admission revealed diffuse bleeding from multiple telangiectasias on the anterior wall of the antrum and bulbus. We treated this patient with a new non-contact hemostatic method: the argon plasma coagulator (APC). The melena stopped after the first session and the hemoglobin level remained stable for 7 months. No delayed complications have been observed. Gastrointestinal bleeding from chronic radiation gastroduodenitis is rarely reported compared with radiation proctitis. This case demonstrates that APC is effective for hemostasis of diffuse bleeding from radiation gastroduodenitis, just as for radiation protitis. (author)

  6. Line ratio diagnostics in helium and helium seeded argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Boivin, R F [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Loch, S D [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Ballance, C P [Physics Department, Rollins College, White Park, FL 32789 (United States); Branscomb, D [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Pindzola, M S [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States)

    2007-08-15

    We investigate the potential use of line ratio diagnostics to evaluate electron temperature in either helium or helium seeded argon plasmas. Plasmas are produced in a helicon plasma source. A rf compensated Langmuir probe is used to measure both the electron temperature and plasma density while a spectrometer is used to measure He I line intensities from the plasma. For all plasma densities where the electron temperature remains at 5 {+-} 1 eV, three He line ratios are measured. Each experimental ratio is compared with the prediction of three different collisional radiative models. One of these models makes uses of recent R-matrix with pseudo-states calculations for collisional rate coefficients. A discussion related to the different observations and model predictions is presented.

  7. Photodegradation Mechanisms of Tetraphenyl Butadiene Coatings for Liquid Argon Detectors

    CERN Document Server

    Jones, B J P; Conrad, J M; Pla-Dalmau, A

    2013-01-01

    We report on studies of degradation mechanisms of tetraphenyl butadiene (TPB) coatings of the type used in neutrino and dark matter liquid argon experiments. Using gas chromatography coupled to mass spectrometry we have detected the ultraviolet-blocking impurity benzophenone (BP). We monitored the drop in performance and increase of benzophenone concentration in TPB plates with exposure to ultraviolet (UV) light, and demonstrate the correlation between these two variables. Based on the presence and initially exponential increase in the concentration of benzophenone observed, we propose that TPB degradation is a free radical-mediated photooxidation reaction, which is subsequently confirmed by displaying delayed degradation using a free radical inhibitor. Finally we show that the performance of wavelength-shifting coatings of the type envisioned for the LBNE experiment can be improved by 10-20%, with significantly delayed UV degradation, by using a 20% admixture of 4-tert-Butylcatechol.

  8. Kinetic modeling of the Townsend breakdown in argon

    Energy Technology Data Exchange (ETDEWEB)

    Macheret, S. O.; Shneider, M. N. [Department of Mechanical and Aerospace Engineering, Princeton University, D-414 Engineering Quadrangle, Princeton, New Jersey 08544 (United States)

    2013-10-15

    Kinetic modeling of the Townsend breakdown in argon was performed in the “forward-back” approximation. The kinetic model was found to adequately describe the left branch of the Paschen curve, and the important role of ionization by fast ions and atoms near the cathode, as well as the increase in secondary emission coefficient in strong electric fields described in the literature, was confirmed. The modeling also showed that the electron energy distribution function develops a beam of high-energy electrons and that the runaway effect, i.e., the monotonic increase of the mean electron energy with the distance from the cathode, occurs at the left branch of the Paschen curve.

  9. Uranium (III) precipitation in molten chloride by wet argon sparging

    Science.gov (United States)

    Vigier, Jean-François; Laplace, Annabelle; Renard, Catherine; Miguirditchian, Manuel; Abraham, Francis

    2016-06-01

    In the context of pyrochemical processes for nuclear fuel treatment, the precipitation of uranium (III) in molten salt LiCl-CaCl2 (30-70 mol%) at 705 °C is studied. First, this molten chloride is characterized with the determination of the water dissociation constant. With a value of 10-4.0, the salt has oxoacid properties. Then, the uranium (III) precipitation using wet argon sparging is studied. The salt is prepared using UCl3 precursor. At the end of the precipitation, the salt is totally free of solubilized uranium. The main part is converted into UO2 powder but some uranium is lost during the process due to the volatility of uranium chloride. The main impurity of the resulting powder is calcium. The consequences of oxidative and reductive conditions on precipitation are studied. Finally, coprecipitation of uranium (III) and neodymium (III) is studied, showing a higher sensitivity of uranium (III) than neodymium (III) to precipitation.

  10. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    Science.gov (United States)

    Efthymiopoulos, Ilias

    2001-04-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs.

  11. Characterization of SF6/Argon Plasmas for Microelectronics Applications; TOPICAL

    International Nuclear Information System (INIS)

    This report documents measurements in inductively driven plasmas containing SF(sub 6)/Argon gas mixtures. The data in this report is presented in a series of appendices with a minimum of interpretation. During the course of this work we investigated: the electron and negative ion density using microwave interferometry and laser photodetachment; the optical emission; plasma species using mass spectrometry, and the ion energy distributions at the surface of the rf biased electrode in several configurations. The goal of this work was to assemble a consistent set of data to understand the important chemical mechanisms in SF(sub 6) based processing of materials and to validate models of the gas and surface processes

  12. Photodegradation mechanisms of tetraphenyl butadiene coatings for liquid argon detectors

    Science.gov (United States)

    Jones, B. J. P.; VanGemert, J. K.; Conrad, J. M.; Pla-Dalmau, A.

    2013-01-01

    We report on studies of degradation mechanisms of tetraphenyl butadiene (TPB) coatings of the type used in neutrino and dark matter liquid argon experiments. Using gas chromatography coupled to mass spectrometry we have detected the ultraviolet-blocking impurity benzophenone. We monitored the drop in performance and increase of benzophenone concentration in TPB plates with exposure to ultraviolet (UV) light, and demonstrate the correlation between these two variables. Based on the presence and initially exponential increase in the concentration of benzophenone observed, we propose that TPB degradation is a free radical-mediated photooxidation reaction, which is subsequently confirmed by displaying delayed degradation using a free radical inhibitor. Finally we show that the performance of wavelength-shifting coatings of the type envisioned for the LBNE experiment can be improved by 10-20%, with significantly delayed UV degradation, by using a 20% admixture of 4-tert-Butylcatechol.

  13. Liquid Argon Cryogenic Detector Calibration by Inelastic Scattering of Neutrons

    CERN Document Server

    Polosatkin, Sergey; Dolgov, Alexander

    2014-01-01

    A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron generator. Features of kinematics of inelastic scattering cause sufficient (forty times) increase in count rate of useful events relative to traditional scheme exploited elastic scattering with the same recoil energy and compatible energy resolution. The benefits of the proposed scheme of calibration most well implemented with the use of tagged neutron generator as a neutron source that allows to eliminate background originated from casual coincidence of signals on cryogenic detector and additional detector of scattered neutrons.

  14. The liquid argon TPC for the ICARUS experiment

    CERN Document Server

    Arneodo, F

    1997-01-01

    The ICARUS project aims at the realisation of a large liquid argon TPC to be run at the Underground Laboratories of Gran Sasso in Italy. An intense R&D; activity has put on firm grounds this new detector technology and experimentally confirmed its feasibility on a few ton scale. Based on these solid achievements, the collaboration is now confident of being able to build and safely operate a multi-kton detector. The reseach program of the experiment involves the systematic study of a wide spectrum of physical phenomena covering many orders of magnitude in the energy deposited in the detector: from the few MeV of solar neutrino interactions, to the about one GeV of the proton decay and atmospheric neutrinos, up to the higher energies of neutrinos from accelerators.

  15. Response Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter

    CERN Document Server

    Aharrouche, M; Di Ciaccio, L; El Kacimi, M; Gaumer, O; Gouanère, M; Goujdami, D; Lafaye, R; Laplace, S; Le Maner, C; Neukermans, L; Perrodo, P; Poggioli, L; Prieur, D; Przysiezniak, H; Sauvage, G; Wingerter-Seez, I; Zitoun, R; Lanni, F; Lü, L; Ma, H; Rajagopalan, S; Takai, H; Belymam, A; Benchekroun, D; Hakimi, M; Hoummada, A; Gao, Y; Stroynowsk, R; Aleksa, M; Carli, T; Fassnacht, P; Gianotti, F; Hervás, L; Lampl, W; Collot, J; Hostachy, J Y; Ledroit-Guillon, F; Malek, F; Martin, P; Viret, S; Leltchouk, M; Parsons, J A; Simion, S; Barreiro, F; Del Peso, J; Labarga, L; Oliver, C; Rodier, S; Barrillon, P; Benchouk, C; Djama, F; Hubaut, F; Monnier, E; Pralavorio, P; Sauvage, D; Serfon, C; Tisserant, S; Tóth, J; Banfi, D; Carminati, L; Cavalli, D; Costa, G; Delmastro, M; Fanti, M; Mandell, L; Mazzanti, M; Tartarelli, F; Kotov, K; Maslennikov, A; Pospelov, G; Tikhonov, Yu; Bourdarios, C; Fayard, L; Fournier, D; Iconomidou-Fayard, L; Kado, M; Parrour, G; Puzo, P; Rousseau, D; Sacco, R; Serin, L; Unal, G; Zerwas, D; Dekhissi, B; Derkaoui, J; EL Kharrim, A; Maaroufi, F; Cleland, W; Lacour, D; Laforge, B; Nikolic-Audit, I; Schwemling, Ph; Ghazlane, H; Cherkaoui El Moursli, R; Idrissi Fakhr-Eddine, A; Boonekamp, M; Kerschen, N; Mansoulié, B; Meyer, P; Schwindlingy, J; Lund-Jensen, B

    2007-01-01

    The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.

  16. A Thermodynamic Model for Argon Plasma Kernel Formation

    Directory of Open Access Journals (Sweden)

    James Keck

    2010-11-01

    Full Text Available Plasma kernel formation of argon is studied experimentally and theoretically. The experiments have been performed in a constant volume cylindrical vessel located in a shadowgraph system. The experiments have been done in constant pressure. The energy of plasma is supplied by an ignition system through two electrodes located in the vessel. The experiments have been done with two different spark energies to study the effect of input energy on kernel growth and its properties. A thermodynamic model employing mass and energy balance was developed to predict the experimental data. The agreement between experiments and model prediction is very good. The effect of various parameters such as initial temperature, initial radius of the kernel, and the radiation energy loss have been investigated and it has been concluded that initial condition is very important on formation and expansion of the kernel.

  17. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    CERN Document Server

    Efthymiopoulos, I

    2001-01-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs. (3 refs).

  18. Attosecond Coherent Control of Single and Double Photoionization in Argon.

    Science.gov (United States)

    Hogle, C W; Tong, X M; Martin, L; Murnane, M M; Kapteyn, H C; Ranitovic, P

    2015-10-23

    Ultrafast high harmonic beams provide new opportunities for coherently controlling excitation and ionization processes in atoms, molecules, and materials on attosecond time scales by employing multiphoton two-pathway electron-wave-packet quantum interferences. Here we use spectrally tailored and frequency tuned vacuum and extreme ultraviolet harmonic combs, together with two phase-locked infrared laser fields, to show how the total single and double photoionization yields of argon can be coherently modulated by controlling the relative phases of both optical and electronic-wave-packet quantum interferences. This Letter is the first to apply quantum control techniques to double photoionization, which is a fundamental process where a single, high-energy photon ionizes two electrons simultaneously from an atom. PMID:26551112

  19. Dynamic resonances and tunnelling in the multiphoton ionization of argon

    International Nuclear Information System (INIS)

    We present results of wavepacket simulations for multiphoton ionization in argon. A single active electron model is applied to estimate the single-electron ionization rates and photoelectron energy distributions for λ = 390 nm light with intensities up to I = 2 x 1014 W cm-2. The multiphoton ionization rates are compared with R-matrix Floquet calculations and found to be in very good agreement. The photoelectron energy distribution is used to study the nature of ionization at the higher intensities. Our results are consistent with recent calculations and experiments which show the imprint of the tunnelling process in the multiphoton regime. For few-cycle intense pulses, we find that the strong modulation of intensity and increased bandwidth leads to dynamic mixing of the 3d and 5s resonances.

  20. The ATLAS liquid Argon calorimeters read-out system

    CERN Document Server

    Blondel, A; Fayard, L; La Marra, D; Léger, A; Matricon, P; Perrot, G; Poggioli, L; Prast, J; Riu, I; Simion, S

    2004-01-01

    The calorimetry of the ATLAS experiment takes advantage of different detectors based on the liquid Argon (LAr) technology. Signals from the LAr calorimeters are processed by various stages before being delivered to the Data Acquisition system. The calorimeter cell signals are received by the front-end boards, which digitize a predetermined number of samples of the bipolar waveform and sends them to the Read-Out Driver (ROD) boards. The ROD board receives triggered data from 1028 calorimeter cells, and determines the precise energy and timing of the signals by processing the discrete samplings of the pulse. In addition, it formats the digital stream for the following elements of the DAQ chain, and performs monitoring. The architecture and functionality of the ATLAS LAr ROD board are discussed, along with the final design of the Processing Unit boards housing the Digital Signal Processors (DSP). (9 refs).

  1. Electron-ion recombination study in argon at atmospheric pressure

    International Nuclear Information System (INIS)

    This study deals with a wall-stabilized arc burning in argon at atmospheric pressure. A transient mode is obtained using a fast thyristor connected to the electrodes, which short-circuits the discharge. By means of two wavelengths laser interferometry and spectroscopy measurements we have determined the temporal changes of the electron density, ground state atom density and excited atom density. We have shown that, when the electric field is suppressed, the electron temperature rapidly decreases to the gas temperature before changing electron and atom densities. This phenomenon is applied to determine the gas temperature and to evaluate the role played by ionization in electron density balance. The coefficients of ambipolar diffusion, ionization and recombination and an apparent recombination coefficient are determined versus electron temperature and compared with theoretical values

  2. Atmospheric dispersion of argon-41 from anuclear research reactor: measurement and modeling of plume geometry and gamma radiation field

    DEFF Research Database (Denmark)

    Lauritzen, Bent; Astrup, Poul; Drews, Martin;

    2003-01-01

    An atmospheric dispersion experiment was conducted using a visible tracer along with the routine release of argon-41 from the BR1 research reactor in Mol, Belgium. Simultaneous measurements of plume geometry and radiation fields for argon-41 decay were performed as well as measurements of the argon...

  3. Argon Kα measurement on DIII endash D by Ross filters technique (abstract)

    International Nuclear Information System (INIS)

    Techniques to reduce the heat flux to the divertor plates in tokamak power plants and the consequent erosion of, and subsequent damage to the divertor target plates include the injection of impurities such as argon, that can dissipate the energy (through radiative or collisional processes) before it reaches the target plates. An important issue with this type of scheme is poisoning of the plasma core by the impurities introduced in the divertor region. Subsequently, there is a desire to measure the profiles of the injected impurities in the core. X-ray Ross filters with an effective narrow band pass centered on the argon Kα line at 3.2 keV, have been installed on two of the existing x-ray arrays on DIII endash D in order to help determine the argon concentration profiles. Emissivity profiles of the Kα lines and the emissivity profiles for the argon enhanced continuum can be inferred from the inverted filtered x-ray brightness signals if Te, ne, and Ar18+ profiles are known. The MIST code is used to couple the filtered x-ray signals to the time dependent measurements of Te and ne. Further, the Ar16+ profiles measured by charge transfer spectroscopy, are used as a constraint on the MIST code runs to calculate Ar18+ profiles and unfold the argon emissivity profiles. A discussion of the Ross filters, the DIII endash D argon data, and the data analysis scheme for inferring argon emissivity profiles will be discussed. Estimates of the total argon concentration in the core determined from this technique in DIII endash D argon puff experiments will be presented. copyright 1999 American Institute of Physics

  4. Wetting and evaporation of argon nanodroplets on smooth and rough substrates: Molecular dynamics simulations

    Science.gov (United States)

    Li, Qun; Wang, Baohe; Chen, Yonggang; Zhao, Zongchang

    2016-10-01

    Wetting and evaporation behaviors of argon nanodroplets on smooth and rough substrates are studied using molecular dynamics simulations. Effects of interaction energy between solid and argon atoms on wetting and evaporation and differences between nanodroplets on smooth and rough substrates have been investigated. The results show that for both smooth and rough substrates, as the interaction energy between solid and argon atoms increases, the contact angle and total evaporation increase. For rough substrates, the variations of contact angle and contact radius during evaporation progress are much more complex and the total evaporation is much larger than that of smooth substrates.

  5. A Study of Dielectric Breakdown Along Insulators Surrounding Conductors in Liquid Argon

    CERN Document Server

    Lockwitz, Sarah

    2015-01-01

    High voltage breakdown in liquid argon is an important consideration in the design of liquid argon time projection chambers, which are often used as neutrino and dark matter detectors. We have made systematic measurements of breakdown voltages in liquid argon along insulators surrounding negative rod electrodes. The purpose of these tests is to understand the effects of materials, of breakdown path length, and of surface topology. We have found no material-specific effects other than those due to their permittivity. We have found no dependence on breakdown voltage on the length of the exposed insulator. A model for the breakdown mechanism is presented that can help inform future designs.

  6. Design Principles and Operational Results of the Cryogenic System for the ATLAS Liquid Argon Calorimeter

    CERN Document Server

    Fabre, C; Chalifour, M; Gonidec, G; Passardi, Giorgio; Petit, P; Pezzetti, M; Wicek, F

    2009-01-01

    The ATLAS liquid argon calorimeter housed in three independent cryostats containing a total argon volume of about 78 m3 has been installed in the underground cavern. The three detectors have been cooled down following stringent temperature gradient limits and have been filled with liquid argon. The cryostats are now in a stable condition for periods going up to almost two years. The temperature uniformity within each of the three detector volumes is found to be within 70 mK rms, while the temperature stability stays below 5 mK rms.

  7. A new ozone standard - The vapor pressure of ozone at liquid argon temperatures

    Science.gov (United States)

    Mauersberger, K.; Hanson, D.; Morton, J.

    1985-01-01

    The vapor pressure of ozone has been measured at liquid argon temperatures. At the normal boiling point of argon (-185.9 C) an ozone pressure of 0.0405 torr was obtained with an accuracy of + or - 1.5 percent. Increases and decreases in liquid argon temperatures raised and lowered the ozone vapor pressure, respectively. During the vapor pressure measurements the purity of ozone was monitored with a mass spectrometer. The proposed ozone standard will considerably improve the calibration of experiments for atmospheric research, the determination of absorption cross sections and other laboratory ozone studies.

  8. Surface compositional changes in GaAs subjected to argon plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Surdu-Bob, C.C.; Sullivan, J.L.; Saied, S.O.; Layberry, R.; Aflori, M

    2002-12-30

    X-ray photoelectron spectroscopy (XPS) has been employed to study surface compositional changes in GaAs (1 0 0) subjected to argon plasma treatment. The experimental results have been explained in terms of predicted argon ion energies, measured ion densities and etch rates. A model is proposed for the processes taking place at the surface of GaAs in terms of segregation, sputtering and surface relaxation. Stopping and range of ions in matter (SRIM) code has also been employedan aid to identification of the mechanisms responsible for the compositional changes. Argon plasma treatment induced surface oxidation at very low energies and sputtering and surface damage with increasing energy.

  9. Changes in a surface of polycrystalline aluminum upon bombardment with argon ions

    Science.gov (United States)

    Ashkhotov, O. G.; Ashkhotova, I. B.; Bliev, A. P.; Magkoev, T. T.; Krymshokalova, D. A.

    2014-10-01

    The interaction between argon ions and a natural oxide layer of polycrystalline aluminum is studied via Auger electron (AE) and electron energy loss (EEL) spectroscopy. It is found that bombardment with argon ions whose energy is lower than the Al2O3 sputtering threshold results in the accumulation of bombarding ions in interstitial surface voids, thus forming a supersaturated solid solution of target atoms and bombarding ions of argon and nitrogen entrapped by the ion beam from the residual gas of the working chamber of the spectrometer.

  10. Self-assembled heterogeneous argon/neon core-shell clusters studied by photoelectron spectroscopy.

    Science.gov (United States)

    Lundwall, M; Pokapanich, W; Bergersen, H; Lindblad, A; Rander, T; Ohrwall, G; Tchaplyguine, M; Barth, S; Hergenhahn, U; Svensson, S; Björneholm, O

    2007-06-01

    Clusters formed by a coexpansion process of argon and neon have been studied using synchrotron radiation. Electrons from interatomic Coulombic decay as well as ultraviolet and x-ray photoelectron spectroscopy were used to determine the heterogeneous nature of the clusters and the cluster structure. Binary clusters of argon and neon produced by coexpansion are shown to exhibit a core-shell structure placing argon in the core and neon in the outer shells. Furthermore, the authors show that 2 ML of neon on the argon core is sufficient for neon valence band formation resembling the neon solid. For 1 ML of neon the authors observe a bandwidth narrowing to about half of the bulk value.

  11. Surface Chemistry of Polymers Physical Adsorption of Nitrogen, Argon, Sulfur Dioxide and Neopentane on Polyvinylidene Fluoride

    OpenAIRE

    Houriet, Jean-Philippe; Ghiste, Patrick; Stoeckli, Fritz

    2007-01-01

    The adsorption of nitrogen, argon, sulfur dioxide and neopentane on polyvinylidene fluoride has been measured by static methods and by gas-solid chromatography. The polymer has a homogeneous surface of low energy, which is not significantly affected by heating.

  12. Surface modification of polypropylene using argon plasma: Statistical optimization of the process variables

    International Nuclear Information System (INIS)

    Low pressure plasma treatment using radiofrequency (rf) discharge of argon gas was employed to improve the hydrophilicity of polypropylene. The effects of argon plasma on the wettability, surface chemistry and surface morphology of polypropylene were studied using static contact angle measurements, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and atomic force microscopy (AFM). Increase in surface energy of polypropylene was observed as a result of argon plasma treatment. SEM and AFM images revealed the increased surface roughness. A set of identified process variables (rf power, pressure, argon flow rate and time) were used in this study and were optimized using central composite design (CCD) of response surface methodology (RSM). A statistical model was developed to represent the surface energy in terms of the process variables mentioned above. Accuracy of the model was verified and found to be high.

  13. Simulations of argon accident scenarios in the ATLAS experimental cavern a safety analysis

    CERN Document Server

    Balda, F

    2002-01-01

    Some characteristic accidents in the ATLAS experimental cavern (UX15) are simulated by means of STAR-CD, a code using the "Finite-Volume" method. These accidents involve different liquid argon leaks from the barrel cryostat of the detector, thus causing the dispersion of the argon into the Muon Chamber region and the evaporation of the liquid. The subsequent temperature gradients and distribution of argon concentrations, as well as their evolution in time are simulated and discussed, with the purpose of analysing the dangers related to asphyxiation and to contact with cryogenic fluids for the working personnel. A summary of the theory that stands behind the code is also given. In order to validate the models, an experimental test on a liquid argon spill performed earlier is simulated, showing that the program is able to output reliable results. At the end, some safety-related recommendations are listed.

  14. Pose Measurement Performance of the Argon Relative Navigation Sensor Suite in Simulated Flight Conditions

    Science.gov (United States)

    Galante, Joseph M.; Eepoel, John Van; Strube, Matt; Gill, Nat; Gonzalez, Marcelo; Hyslop, Andrew; Patrick, Bryan

    2012-01-01

    Argon is a flight-ready sensor suite with two visual cameras, a flash LIDAR, an on- board flight computer, and associated electronics. Argon was designed to provide sensing capabilities for relative navigation during proximity, rendezvous, and docking operations between spacecraft. A rigorous ground test campaign assessed the performance capability of the Argon navigation suite to measure the relative pose of high-fidelity satellite mock-ups during a variety of simulated rendezvous and proximity maneuvers facilitated by robot manipulators in a variety of lighting conditions representative of the orbital environment. A brief description of the Argon suite and test setup are given as well as an analysis of the performance of the system in simulated proximity and rendezvous operations.

  15. Formation and characterization of magnesium bisozonide and carbonyl complexes in solid argon.

    Science.gov (United States)

    Wang, Guanjun; Gong, Yu; Zhang, Qingqing; Zhou, Mingfei

    2010-10-14

    The reactions of magnesium atoms with dioxygen and dioxygen/carbon monoxide mixture have been investigated by matrix isolation infrared absorption spectroscopy. Magnesium atoms react with dioxygen in solid argon to form the inserted MgO(2) molecules under UV excitation, which were previously characterized. Annealing allows the dioxygen molecules to diffuse and to react with MgO(2) and form the magnesium bisozonide complex, Mg(O(3))(2), which is proposed to be coordinated by two argon atoms in solid argon matrix. The Mg(O(3))(2)(Ar)(2) complex is characterized to have two equivalent side-on bonded ozonide ligands with a D(2h) symmetry. The coordinated argon atoms can be replaced by carbon monoxide to give the magnesium bisozonide dicarbonyl complex, Mg(O(3))(2)(CO)(2), a neutral magnesium carbonyl complex with CO binding to the Mg(2+) center. PMID:20857987

  16. Dynamic range compression in a liquid argon calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Cleland, W.E. [Univ. of Pittsburgh, PA (United States); Lissauer, D.; Radeka, V.; Rescia, S.; Takai, H. [Brookhaven National Lab., Upton, NY (United States); Wingerter-Seez, I. [LAPP, Annecy-le-Vieux (France)

    1996-12-31

    The anticipated range of particle energies at the LHC, coupled with the need for precision, low noise calorimetry makes severe demands on the dynamic range of the calorimeter readout. A common approach to this problem is to use shapers with two or more gain scales. In this paper, the authors describe their experience with a new approach in which a preamplifier with dynamic gain compression is used. An unavoidable consequence of dynamic gain adjustment is that the peaking time of the shaper output signal becomes amplitude dependent. The authors have carried out a test of such a readout system in the RD3 calorimeter, a liquid argon device with accordion geometry. The calibration system is used to determine both the gain of the individual channels as well as to map the shape of the waveform as a function of signal amplitude. A new procedure for waveform analysis, in which the fitted parameters describe the impulse response of the system, permits a straightforward translation of the calibration waveform to the waveform generated by a particle crossing the ionization gap. They find that the linearity and resolution of the calorimeter is equivalent to that obtained with linear preamplifiers, up to an energy of 200 GeV.

  17. Coherent set of electron cross sections for argon

    Science.gov (United States)

    Alves, L. L.; Ferreira, C. M.

    2011-10-01

    This paper presents a coherent set of electron impact cross sections for argon (elastic momentum-transfer, inelastic for the excitation of 37 levels Ar(4s,4p,3d,5p,4d,6s) and ionization), which was recently uploaded onto the LXcat IST-Lisbon database. The cross section set was validated by comparing calculated swarm parameters (electron mobility and characteristic energy) and rate coefficients (Townsend ionization coefficient and direct + cascade excitation coefficients to the 4s and 4p states) with available experimental data, for E / N = 10-4 - 100 Td and Tg = 300, 77 K. The validation procedure involves the solution to the homogeneous two-term electron Boltzmann equation, resorting to three different solvers: (i) IST-Lisbon's (ii) BOLSIG+ (v1.2) with LXcat; (iii) BOLSIG+ (v1.23). The results obtained with these solvers are compared to evidence the importance of certain numerical features related with both the energy-grid (number of points, grid-type and maximum energy value) and the interpolation scheme adopted for the cross sections. In particular, the latter can cause a 6% variation on the values of swarm parameters at intermediate E/Ns.

  18. An update of argon inelastic cross sections for plasma discharges

    International Nuclear Information System (INIS)

    This paper proposes a coherent set of electron impact inelastic cross sections for argon, based on recent experimental measurements. The updated set is validated by comparing calculated swarm parameters and rate coefficients (obtained by solving the two-term approximation electron Boltzmann equation) with available experimental data. This validation procedure is usually adopted when the cross section set is to be later used in plasma discharge modelling. Simulation results for the electron drift velocity and characteristic energy are in very good agreement with experimental values of these quantities. Calculations, using cross section sets proposed by different authors, of the total (direct + cascade) excitation coefficients to the 4s and 4p states, and of the Townsend ionization coefficient, show that the present set ensures the best overall agreement with measured values. The agreement is particularly good for the excitation coefficient to metastable 4s'[1/2]0 and the Townsend ionization coefficient, which are probably the most relevant electron macroscopic coefficients in the modelling of discharge plasmas

  19. Argon defect complexes in low energy Ar irradiated molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    van Veen, A.; Buters, W.T.M.; van der Kolk, G.J.; Caspers, L.M. (Interuniversitair Reactor Instituut, Delft (Netherlands)); Armstrong, T.R. (Victoria Univ., Wellington (New Zealand). Dept. of Physics)

    1982-03-15

    Thermal desorption spectrometry has been used to study the defects created in Mo irradiated along the <110> direction with Ar ions ranging in energy from 0.1 to 2 keV. In addition to monitoring the release of the implanted Ar, additional information has been obtained by decoration of the defects with low energy helium and subsequent monitoring of the helium release. The studies show evidence that the Ar can be trapped in both substitutional sites and in a configuration in which the Ar is associated with vacancies (ArVsub(n), n >= 2). Most of the Ar implanted at high energy is released at approx. equal to 1500 K by thermal vacancy assisted diffusion. Argon trapped closer to the surface is released at lower temperatures via at least three different surface related release mechanisms. Additional results are presented on the interaction of self interstitial atoms (introduced by 100 eV Xe bombardment) with the Ar defects. Substitutional Ar is found to convert to interstitial Ar which seems to be mobile at room temperature. The Ar-vacancy complexes are found to be reduced to substitutional Ar. The results of atomistic calculations of the release mechanisms will also be presented.

  20. Scintillation Light from Cosmic-Ray Muons in Liquid Argon

    CERN Document Server

    Whittington, Denver

    2014-01-01

    This paper reports the results of the first experiment to directly measure the properties of the scintillation light generated by minimum ionizing cosmic-ray muons in liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches, as well as for particle identification. The experiment was carried out at the TallBo facility at Fermilab using prototype light guides and electronics developed for the Long-Baseline Neutrino Experiment. Analysis of the time-resolved structure of the scintillation light from cosmic-ray muons gives $\\langle \\tau_{\\text{T}}\\rangle = 1.43 \\pm 0.04~\\text{(stat.)} \\pm 0.007~\\text{(sys.)}~\\mu$s for the triplet light decay time constant. The ratio of singlet to triplet light measured using surface-coated light guides is $R = 0.39 \\pm 0.01~\\text{(stat.)} \\pm 0.008~\\text{(sys.)}$. There is some evidence that this value is not consistent with $R$ for minimum ionizing electrons. However, the value for $...

  1. State-selective radiative recombination cross sections of argon ions

    International Nuclear Information System (INIS)

    The n-, (n,l)- and fine-structure level state-selective radiative recombinations (RR) cross sections of argon ions Ar18+,Ar13+,Ar7+ and Ar+ are obtained with the semi-classical Kramer formula, the relativistic self-consistent field (RSCF) method and the relativistic configuration interaction (RCI) method. It is found that for the highly charged ions with few electrons, the cross sections calculated with these three methods are in good agreement with each other. But as the number of electrons increases, the Kramer formula deviates from the RSCF and RCI results. For instance, when the energy of the incident electron is larger than 100 eV, the n-state selective cross sections of Ar7+ calculated from the Kramer formula are underestimated for more than 50%. The RSCF results are in general agreement with the RCI results. However, for the low charged ions, a clear distinction appears due to the strong configuration interaction, especially near the Cooper minimum. The n-resolved (n≤10) and total Maxwellian averaged rate coefficients are calculated, and the analytic fitting parameters are also provided. -- Highlights: ► The RR cross sections of Ar18+, Ar13+, Ar7+ and Ar+ are obtained. ► The Kramer formula, the relativistic self-consistent field and RCI methods are used. ► Results from three methods are compared with each other.

  2. Electronics calibration board for the ATLAS liquid argon calorimeters

    International Nuclear Information System (INIS)

    To calibrate the energy response of the ATLAS liquid argon calorimeter, an electronics calibration board has been designed; it delivers a signal whose shape is close to the calorimeter ionization current signal with amplitude up to 100 mA in 50 Ω with 16 bit dynamic range. The amplitude of this signal is designed to be uniform over all calorimeters channels, stable in time and with an integral linearity much better that the electronics readout. The various R and D phases and most of the difficulties met are discussed and illustrated by many measurements. The custom design circuits are described and the layout of the ATLAS calibration board presented. The procedure used to qualify the boards is explained and the performance obtained illustrated: a dynamic range up to 3 TeV in three energy scales with an integral linearity better than 0.1% in each of them, a response uniformity better than 0.2% and a stability better than 0.1%. The performance of the board is well within the ATLAS requirements. Finally, in situ measurements done on the ATLAS calorimeter are shown to validate these performances

  3. Methane from benzene in argon dielectric barrier discharge

    International Nuclear Information System (INIS)

    Highlights: ► Efficient on-line conversion of benzene to methane at room temperature. ► Absence of other H-atom donor suggests new type of chemistry. ► For parent loss > 90%, methane yield was ∼40% of limit due to H-atom availability. ► Surface moisture contributed ·OH radical for trace phenolic products’ formation. ► This method may emerge as an exploitable tactic for pollutants’ usable alterations. -- Abstract: A first-time account of direct, on-line, instantaneous and efficient chemical conversion of gas phase benzene to methane in argon Dielectric Barrier Discharge (DBD) is presented. In the absence of another overt hydrogen-donating source, potency of analogous parents toward methane generation is found to follow the order: benzene > toluene > p-xylene. Simultaneous production of trace amounts of phenolic surface deposits suggest (a) prompt decomposition of the parent molecules, including a large fraction yielding atomic transients (H-atom), (b) continuous and appropriate recombination of such parts, and (c) trace moisture in parent contributing ·OH radicals and additional H-atoms, which suitably react with the unreacted fraction of the parent, and also other intermediates. Results highlight Ar DBD to be a simple and exploitable technology for transforming undesirable hazardous aromatics to usable/useful low molecular weight open-chain products following the principles of green chemistry and engineering

  4. Optically Forbidden Excitations of 3s Electron of Argon by Fast Electron Impact

    Institute of Scientific and Technical Information of China (English)

    朱林繁; 成华东; 刘小井; 田鹏; 苑震生; 李文斌; 徐克尊

    2003-01-01

    The electron energy loss spectrum of argon in the energy region of 24.5-30.5eV was measured at 2.5 keV impact energy. The line profile parameters of the optically forbidden excitations of 3s-1ns (n = 4-6) and 3s-1nd (n = 3-7) of argon, I.e.,Eγ,Г,q and p,were determined.

  5. Benchmarking TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    OpenAIRE

    Baptista, B.; Bugel, L.; Chiu, C; Conrad, J. M.; Ignarra, C. M.; Jones, B. J. P.; Katori, T.; Mufson, S.

    2012-01-01

    Scintillation light from liquid argon is produced at 128 nm and thus must be shifted to visible wavelengths in light detection systems used for Liquid Argon Time Projection Chambers (LArTPCs). To date, designs have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we show that the response of lightguides coated with TPB in a UV Transmitting (UV...

  6. TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    CERN Document Server

    Ignarra, C M

    2013-01-01

    Light detection systems in Liquid Argon Time Projection Chambers (LArTPCs) require the detection of the 128 nm light produced during argon scintillation. Most detectors use Tetraphenyl Butadiene (TPB) to shift the wavelength of the light into a range visible to Photomultiplier Tubes (PMTs). These proceedings summarize characterizations of light-guides coated with a matrix of TPB in UV transmitting acrylic which are more compact than existing LArTPC light collection systems.

  7. TPB-coated light guides for liquid argon TPC light detection systems

    Science.gov (United States)

    Ignarra, C. M.

    2013-10-01

    Light detection systems in Liquid Argon Time Projection Chambers (LArTPCs) require the detection of the 128 nm light produced during argon scintillation. Most detectors use Tetraphenyl Butadiene (TPB) to shift the wavelength of the light into a range visible to Photomultiplier Tubes (PMTs). These proceedings summarize characterizations of light-guides coated with a matrix of TPB in UV transmitting acrylic which are more compact than existing LArTPC light collection systems.

  8. Effect of Ginkgo biloba on the lesions induced by retinal argon laser photocoagulation in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Clairambault, P.; Pairault, C.; Droy-Lefaix, M.T.; Magnier, B.; Magnier, M.

    1986-01-09

    In rabbits, retinal argon laser photocoagulation disrupts the arrangement of cell layers and produces interstitial edema. Photochemical and thermal energy is released with production of free oxygenated radicals that are responsible for destruction of cell membranes. Retinal argon laser photocoagulation in rabbits was used as a pharmacologic model to evaluate the protective effect of EGB 761 against membrane lesions and edema. As a strong free radicals scavengers, EGB 761 confirms its protective action on cells membranes and its anti-edema effect.

  9. Configurational Entropy,Diffusivity and Potential Energy Landscape in Liquid Argon

    Institute of Scientific and Technical Information of China (English)

    DUAN Yong-Ping; MA Cong-Xiao; LI Jia-Yun; LI Cong; WANG Dan; LI Mei-Li; SUN Min-Hua

    2009-01-01

    The configurational entropy, diffusion coefficient, dynamics and thermodynamics fragility indices of liquid argon are calculated using molecular dynamics simulations at two densities. The relationship between dynamics and thermodynamics properties is studied. The diffusion coefficient depends linearly on configurational entropy, which is consistent with the hypothesis of Adam-Gibbs. The consistence of dynamics and thermodynamics fragility indices demonstrates that dynamical behaviour is governed by thermodynamics behaviour in glass transition of liquid argon.

  10. Effect of Ginkgo biloba on the lesions induced by retinal argon laser photocoagulation in rabbits

    International Nuclear Information System (INIS)

    In rabbits, retinal argon laser photocoagulation disrupts the arrangement of cell layers and produces interstitial edema. Photochemical and thermal energy is released with production of free oxygenated radicals that are responsible for destruction of cell membranes. Retinal argon laser photocoagulation in rabbits was used as a pharmacologic model to evaluate the protective effect of EGB 761 against membrane lesions and edema. As a strong free radicals scavengers, EGB 761 confirms its protective action on cells membranes and its anti-edema effect

  11. A correction to Birks' Law in liquid argon ionization chamber simulations for highly ionizing particles

    International Nuclear Information System (INIS)

    We present a study of the performance of Birks' Law in liquid argon ionization chamber simulations as applied to highly ionizing particles, such as particles with multiple electric charges or with magnetic charge. We used Birks' Law to model recombination effects in a GEANT4 simulation of heavy ions in a liquid argon calorimeter. We then compared the simulation to published heavy-ion data to extract a highly ionizing particle correction to Birks' Law.

  12. LArGe: Background suppression using liquid argon (LAr) scintillation for 0$\

    CERN Document Server

    Marco, M D; Schönert, S

    2007-01-01

    Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK Heidelberg are reported. The liquid argon--germanium system (LArGe) is operated as a 4$\\pi$ anti-Compton spectrometer to suppress backgrounds in the HPGe. This R&D is carried out in the framework of the GERDA experiment which searches for 0$\

  13. Discovery of photospheric argon in very hot central stars of planetary nebulae and white dwarfs

    CERN Document Server

    Werner, K; Kruk, J W

    2007-01-01

    We report the first discovery of argon in hot evolved stars and white dwarfs. We have identified the ArVII 1063.55A line in some of the hottest known (Teff=95000-110000 K) central stars of planetary nebulae and (pre-) white dwarfs of various spectral type. We determine the argon abundance and compare it to theoretical predictions from stellar evolution theory as well as from diffusion calculations. We analyze high-resolution spectra taken with the Far Ultraviolet Spectroscopic Explorer. We use non-LTE line-blanketed model atmospheres and perform line-formation calculations to compute synthetic argon line profiles. We find a solar argon abundance in the H-rich central star NGC1360 and in the H-deficient PG1159 star PG1424+535. This confirms stellar evolution modeling that predicts that the argon abundance remains almost unaffected by nucleosynthesis. For the DAO-type central star NGC7293 and the hot DA white dwarfs PG0948+534 and REJ1738+669 we find argon abundances that are up to three orders of magnitude sma...

  14. Numerical study of breakdown pattern induced by an intense microwave under nitrogen and argon gases

    Science.gov (United States)

    Takahashi, Masayuki; Ohnishi, Naofumi

    2016-07-01

    Filamentary plasma induced by microwave beam irradiation was reproduced in nitrogen and argon by combining fluid or particle plasma models with electromagnetic wave propagation. Transport coefficients used in the fluid model are estimated from particle simulation to maintain consistency of the breakdown structure between the fluid and particle models. A discrete structure was obtained using the one-dimensional (1D) fluid model, because a standing wave is generated in front of the plasma when the incident microwave beam is reflected by the overcritical plasma, which agrees with the breakdown structure obtained using the 1D particle model. A 2D plasma filament was also reproduced using the fluid model in nitrogen and argon. Reflection of the incident microwave in argon becomes stronger than that in nitrogen because of the denser argon plasma. Change in filament shape is induced in argon because the electric field is deformed at the plasma tip owing to stronger wave reflection from the neighboring filament. The propagation speed of the plasma front becomes larger in argon breakdown because of the larger ionization frequency and the larger diffusion coefficient.

  15. Condensed argon isentropic compression with ultrahigh magnetic field pressure: Experimental design. Post-shot report

    Energy Technology Data Exchange (ETDEWEB)

    Bykov, A.I.; Boriskov, G.V.; Dolotenko, M.I. [All-Russian Research Inst. of Experimental Physics, Sarov (Russian Federation)] [and others

    1996-12-31

    This report continues the series of work devoted to experimental study of a high-dense condensed argon state. Remember that according to work of Kwon et. al., hexagonal close-packed structure is profitable in terms of energy rather than face-centered argon structure (stable with zero pressure). What is most interesting and intriguing here is the issue of possible argon metallization, when it is compressed up to the densities more than 9.17 g/cm{sup 3}. In the experiment of 1995 (the arrangement and data are described in a cited reference) the authors recorded appearance of conductivity in argon, which is non-conductive in the initial state, when it is compressed more than a factor of four. The peak value of argon specific conductivity recorded in this experiment did not exceed 10 (Ohm x cm){sup {minus}1}. This value of conductivity is characteristic of semiconductors, but not metals, which have 10{sup 4} (Ohm x cm){sup {minus}1}. At this stage of the work the main attention is paid to recording of argon conductive state and studying the possibilities of multiframed radiography of the sample in the compressed state.

  16. Low radioactivity argon dark matter search results from the DarkSide-50 experiment

    CERN Document Server

    Agnes, P; Albuquerque, I F M; Alexander, T; Alton, A K; Arisaka, K; Back, H O; Baldin, B; Biery, K; Bonfini, G; Bossa, M; Bottino, B; Brigatti, A; Brodsky, J; Budano, F; Bussino, S; Cadeddu, M; Cadonati, L; Cadoni, M; Calaprice, F; Canci, N; Candela, A; Cao, H; Cariello, M; Carlini, M; Catalanotti, S; Cavalcante, P; Chepurnov, A; Cocco, A G; Covone, G; Crippa, L; D'Angelo, D; D'Incecco, M; Davini, S; De Cecco, S; De Deo, M; De Vincenzi, M; Derbin, A; Devoto, 25 A; Di Eusanio, F; Di Pietro, G; Edkins, E; Empl, A; Fan, A; Fiorillo, G; Fomenko, K; Forster, G; Franco, D; Gabriele, F; Galbiati, C; Giganti, C; Goretti, A M; Granato, F; Grandi, L; Gromov, M; Guan, M; Guardincerri, Y; Hackett, B R; Herner, K; Hungerford, E V; Ianni, Al; Ianni, An; James, I; Jollet, C; Keeter, K; Kendziora, C L; Kobychev, V; Koh, G; Korablev, D; Korga, G; Kubankin, A; Li, X; Lissia, M; Lombardi, P; Luitz, S; Ma, Y; Machulin, I N; Mandarano, A; Mari, S M; Maricic, J; Marini, L; Martoff, C J; Meregaglia, A; Meyers, P D; Miletic, T; Milincic, R; Montanari, D; Monte, A; Montuschi, M; Monzani, M; Mosteiro, P; Mount, B J; Muratova, V N; Musico, P; Napolitano, J; Nelson, A; Odrowski, S; Orsini, M; Ortica, F; Pagani, L; Pallavicini, M; Pantic, E; Parmeggiano, S; Pelczar, K; Pelliccia, N; Perasso, S; Pocar, A; Pordes, S; Pugachev, D A; Qian, H; Randle, K; Ranucci, G; Razeto, A; Reinhold, B; Renshaw, A L; Romani, A; Rossi, B; Rossi, N; Rountree, D; Sablone, D; Saggese, P; Saldanha, R; Sands, W; Sangiorgio, S; Savarese, C; Segreto, E; Semenov, D A; Shields, E; Singh, P N; Skorokhvatov, M D; Smallcomb, M; Smirnov, O; Sotnikov, A; Stanford, C; Suvorov, Y; Tartaglia, R; Tatarowicz, J; Testera, G; Tonazzo, A; Trinchese, P; Unzhakov, E V; Vishneva, A; Vogelaar, B; Wada, M; Walker, S; Wang, H; Wang, Y; Watson, A W; Westerdale, S; Wilhelmi, J; Wojcik, M M; Xiang, X; Xu, J; Yang, C; Yoo, J; Zavatarelli, S; Zec, A; Zhong, W; Zhu, C; Zuzel, G

    2015-01-01

    The DarkSide-50 dark matter search reports the first results obtained using a target of low-radioactivity argon extracted from underground sources. The experiment is located at the Laboratori Nazionali del Gran Sasso and uses a two-phase time projection chamber as a detector. A total of 155 kg of low radioactivity argon has been obtained, and we have determined that underground argon is depleted in Ar-39 by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. The underground argon was also found to contain (2.05 +- 0.13) mBq/kg of Kr-85. We found no evidence for dark matter in the form of WIMPs in 70.9 live-days of data with a fiducial mass of (36.9 +- 0.6) kg. When combined with our preceding search with an atmospheric argon target, we set a 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2 ) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2 ).

  17. Results from the first use of low radioactivity argon in a dark matter search

    Energy Technology Data Exchange (ETDEWEB)

    Agnes, P. [Universite Paris Diderot (France). et al.

    2016-04-08

    Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 103 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10-44 cm2 (8.6 x 10-44 cm2, 8.0 x 10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2 , 10 TeV/c2).

  18. Inhaled 45–50% argon augments hypothermic brain protection in a piglet model of perinatal asphyxia

    Science.gov (United States)

    Broad, Kevin D.; Fierens, Igor; Fleiss, Bobbi; Rocha-Ferreira, Eridan; Ezzati, Mojgan; Hassell, Jane; Alonso-Alconada, Daniel; Bainbridge, Alan; Kawano, Go; Ma, Daqing; Tachtsidis, Ilias; Gressens, Pierre; Golay, Xavier; Sanders, Robert D.; Robertson, Nicola J.

    2016-01-01

    Cooling to 33.5 °C in babies with neonatal encephalopathy significantly reduces death and disability, however additional therapies are needed to maximize brain protection. Following hypoxia–ischemia we assessed whether inhaled 45–50% Argon from 2–26 h augmented hypothermia neuroprotection in a neonatal piglet model, using MRS and aEEG, which predict outcome in babies with neonatal encephalopathy, and immunohistochemistry. Following cerebral hypoxia–ischemia, 20 Newborn male Large White piglets < 40 h were randomized to: (i) Cooling (33 °C) from 2–26 h (n = 10); or (ii) Cooling and inhaled 45–50% Argon (Cooling + Argon) from 2–26 h (n = 8). Whole-brain phosphorus-31 and regional proton MRS were acquired at baseline, 24 and 48 h after hypoxia–ischemia. EEG was monitored. At 48 h after hypoxia–ischemia, cell death (TUNEL) was evaluated over 7 brain regions. There were no differences in body weight, duration of hypoxia–ischemia or insult severity; throughout the study there were no differences in heart rate, arterial blood pressure, blood biochemistry and inotrope support. Two piglets in the Cooling + Argon group were excluded. Comparing Cooling + Argon with Cooling there was preservation of whole-brain MRS ATP and PCr/Pi at 48 h after hypoxia–ischemia (p < 0.001 for both) and lower 1H MRS lactate/N acetyl aspartate in white (p = 0.03 and 0.04) but not gray matter at 24 and 48 h. EEG background recovery was faster (p < 0.01) with Cooling + Argon. An overall difference between average cell-death of Cooling versus Cooling + Argon was observed (p < 0.01); estimated cells per mm2 were 23.9 points lower (95% C.I. 7.3–40.5) for the Cooling + Argon versus Cooling. Inhaled 45–50% Argon from 2–26 h augmented hypothermic protection at 48 h after hypoxia–ischemia shown by improved brain energy metabolism on MRS, faster EEG recovery and reduced cell death on TUNEL. Argon may provide a cheap and practical therapy

  19. Modelling steel’s homogenization during argon purging

    Directory of Open Access Journals (Sweden)

    J. Pieprzyca

    2012-12-01

    Full Text Available Purpose: One of the primary tasks that put the steel producers to the test is to reduce production costs while maintaining high quality. This objective is achieved among others through the optimization of conducted technological processes. Commonly used technology of steel homogenization with inert gases is an important stage in the production of steel in which that objective can be accomplished.Design/methodology/approach: Tests of hydrodynamic processes occurring during the steel blowing with inert gases process directly in industrial conditions is very difficult or impossible. Therefore, as the primary research method physical modelling was used. In order to carry out the tests described in the article a physical model of the station for the argon purging was used that is working at the VSB-TU, Department of Metallurgy and Foundry in Ostrava.Findings: As a result the study provided values for the investigated process and determined the appropriate location of the gas-permeable fittings in steelmaking ladle’s bottom plug. This allows to obtain the required conditions for the steel mixing in the entire volume of ladle’s workspace.Research limitations/implications: Tests presented in the article were carried out in the VSB-TU in Ostrava. Due to this fact some research limitations occurs that applies to localization and physical model’s specific construction. Therefore, as a result of cooperation between VSB-TU in Ostrava and the Silesian University of Technology will be carried out the construction of the new research station in Katowice.Practical implications: The results of the research constitute the basis to make changes that will allow the optimization to so far used purge of steel technology.Originality/value: The results presented in the article are addressed to the steel producers and it allows to optimize on-going steel homogenization process that takes place in the ladle

  20. Scintillation light from cosmic-ray muons in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Whittington, Denver Wade [Indiana Univ., Bloomington, IN (United States). Physics Dept.; Mufson, S. [Indiana Univ., Bloomington, IN (United States). Astronomy Dept.; Howard, B. [Indiana Univ., Bloomington, IN (United States). Physics Dept.

    2016-05-01

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a physically-motivated model. Both models find tT = 1:52 ms for the decay time constant of the Ar 2 triplet state. These models also show that the identification of the “early” light fraction in the phenomenological model, FE 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value 0.3 found by dark matter and double b-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  1. Scintillation Light from Cosmic-Ray Muons in Liquid Argon

    Energy Technology Data Exchange (ETDEWEB)

    Whittington, Denver Wade [Indiana U.; Mufson, S. [Indiana U., Bloomington, Dept. Astron.; Howard, B. [Indiana U.

    2015-11-13

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a physically-motivated model. Both models find tT = 1:52 ms for the decay time constant of the Ar 2 triplet state. These models also show that the identification of the “early” light fraction in the phenomenological model, FE 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value 0.3 found by dark matter and double b-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  2. Scintillation light from cosmic-ray muons in liquid argon

    Science.gov (United States)

    Whittington, D.; Mufson, S.; Howard, B.

    2016-05-01

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a composite model. Both models find τT = 1.52 μs for the decay time constant of the Ar2* triplet state. These models also show that the identification of the ``early'' light fraction in the phenomenological model, FE ≈ 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS ≈ 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value ~0.3 found by dark matter and double β-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  3. Argon gas concentration effects on nanostructured molybdenum nitride layer growth using 100 Hz pulsed dc glow discharge

    Science.gov (United States)

    Ikhlaq, U.; Ahmad, R.; Saleem, S.; Shah, M. S.; Umm-i-Kalsoom; Khan, N.; Khalid, N.

    2012-08-01

    The effect of argon concentration (10%-40%) on the surface properties of molybdenum is studied in nitrogen-argon mixture using 100 Hz pulsed dc glow discharge. The analysis is carried out by using X-ray diffractometer (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and Vickers microhardness tester to investigate surface properties of the nitrided samples. XRD results exhibit the formation of molybdenum nitrides. Crystallite size analysis and SEM morphology confirm the growth of nanostructured molybdenum nitride layers. Moreover, significant increase in surface hardness (by a factor of about two times) is found when the sample is treated for 30% argon in nitrogen-argon mixed plasma.

  4. Improved TPB-coated light guides for liquid argon TPC light detection systems

    International Nuclear Information System (INIS)

    Scintillation light produced in liquid argon (LAr) must be shifted from 128 nm to visible wavelengths in light detection systems used for liquid argon time-projection chambers (LArTPCs). To date, LArTPC light collection systems have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we report on light guides with improved attenuation lengths above 100 cm when measured in air. This is an important step in the development of meter-scale light guides for future LArTPCs. Improvements come from using a new acrylic-based coating, diamond-polished cast UV transmitting acrylic bars, and a hand-dipping technique to coat the bars. We discuss a model for connecting bar response in air to response in liquid argon and compare this to data taken in liquid argon. The good agreement between the prediction of the model and the measured response in liquid argon demonstrates that characterization in air is sufficient for quality control of bar production. This model can be used in simulations of light guides for future experiments

  5. Improved TPB-coated light guides for liquid argon TPC light detection systems

    Science.gov (United States)

    Moss, Z.; Bugel, L.; Collin, G.; Conrad, J. M.; Jones, B. J. P.; Moon, J.; Toups, M.; Wongjirad, T.

    2015-08-01

    Scintillation light produced in liquid argon (LAr) must be shifted from 128 nm to visible wavelengths in light detection systems used for liquid argon time-projection chambers (LArTPCs). To date, LArTPC light collection systems have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we report on light guides with improved attenuation lengths above 100 cm when measured in air. This is an important step in the development of meter-scale light guides for future LArTPCs. Improvements come from using a new acrylic-based coating, diamond-polished cast UV transmitting acrylic bars, and a hand-dipping technique to coat the bars. We discuss a model for connecting bar response in air to response in liquid argon and compare this to data taken in liquid argon. The good agreement between the prediction of the model and the measured response in liquid argon demonstrates that characterization in air is sufficient for quality control of bar production. This model can be used in simulations of light guides for future experiments.

  6. Fast-imaging and spectroscopic analysis of atmospheric argon streamers for large gap arc breakdown

    Science.gov (United States)

    Pachuilo, Michael; Stefani, Francis; Bengtson, Roger; Raja, Laxminarayan

    2014-10-01

    A non-equilibrium plasma source has been developed to assist in the low-voltage arc breakdown of large electrode gaps. The source consists of a dielectric embedded wire helically wound around a confining cylindrical quartz chamber. Annular electrodes cap the ends of the quartz chamber. An argon feed gas is used to provide a uniform environment and exhausts to ambient atmospheric conditions. A negative polarity 50 kV trigger pulse is applied to the embedded trigger wire to initiate the arc breakdown. Application of the trigger pulse produces a localized coronal discharges along the inner surface of the quartz tube. The corona provides seed electrons through which streamers propagate from one of the main discharge electrode along the quartz surface until it reaches the opposite electrode to bridge the gap. Once the gap is bridged a spark over occurs and robust arc discharge is formed in the chamber volume. Fast imaging of the streamer propagation establishes its velocity in the range of ~ 100 km/s. Spectroscopy of the streamer discharge in atmospheric argon has been conducted and electron temperature and number density estimated from a collision radiative model. Argon spectrum is dominated by neutral argon lines in the 650--950 nm range, and singly ionized argon lines are observed in the ultra-violet to near UV (300--400 nm). Research was performed in connection with AFOSR Contract FA9550-11-1-0062.

  7. Prediction of the thermophysical properties of pure neon, pure argon, and the binary mixtures neon-argon and argon-krypton by Monte Carlo simulation using ab initio potentials.

    Science.gov (United States)

    Nasrabad, A E; Laghaei, R; Deiters, U K

    2004-10-01

    Gibbs ensemble Monte Carlo simulations were used to test the ability of intermolecular pair potentials derived ab initio from quantum mechanical principles, enhanced by Axilrod-Teller triple-dipole interactions, to predict the vapor-liquid phase equilibria of pure neon, pure argon, and the binary mixtures neon-argon and argon-krypton. The interaction potentials for Ne-Ne, Ar-Ar, Kr-Kr, and Ne-Ar were taken from literature; for Ar-Kr a different potential has been developed. In all cases the quantum mechanical calculations had been carried out with the coupled-cluster approach [CCSD(T) level of theory] and with correlation consistent basis sets; furthermore an extrapolation scheme had been applied to obtain the basis set limit of the interaction energies. The ab initio pair potentials as well as the thermodynamic data based on them are found to be in excellent agreement with experimental data; the only exception is neon. It is shown, however, that in this case the deviations can be quantitatively explained by quantum effects. The interaction potentials that have been developed permit quantitative predictions of high-pressure phase equilibria of noble-gas mixtures.

  8. First measurement of surface nuclear recoil background for argon dark matter searches

    CERN Document Server

    Xu, Jingke; Westerdale, Shawn; Calaprice, Frank; Wright, Alexander; Shi, Zhiming

    2016-01-01

    One major background in direct searches for weakly interacting massive particles (WIMPs) comes from the deposition of radon progeny on detector surfaces. The most dangerous surface background is the $^{206}$Pb recoils produced by $^{210}$Po decays. In this letter, we report the first characterization of this background in liquid argon. The scintillation signal of low energy Pb recoils is measured to be highly quenched in argon, and we estimate that the 103keV $^{206}$Pb recoil background will produce a signal equal to that of a ~5keV (30keV) electron recoil ($^{40}$Ar recoil). In addition, we demonstrate that this dangerous $^{210}$Po surface background can be suppressed by a factor of ~100 or higher using pulse shape discrimination methods, which can make argon dark matter detectors near background-free and enhance their potential for discovery of medium- and high-mass WIMPs. We also discuss the impact on other low background experiments.

  9. The WArP Experiment: A Double-Phase Argon Detector for Dark Matter Searches

    International Nuclear Information System (INIS)

    Cryogenic noble liquids emerged in the previous decade as one of the best media to perform WIMP dark matter searches, in particular due to the possibility to scale detector volumes to multiton sizes. The WArP experiment was then developed as one of the first to implement the idea of coupling Argon in liquid and gas phase, in order to discriminate β/γ-interactions from nuclear recoils and then achieve reliable background rejection. Since its construction, other projects spawned, employing Argon and Xenon and following its steps. The WArP 100l detector was assembled in 2008 at the Gran Sasso National Laboratories (LNGS), as the final step of a years-long R&D programme, aimed at characterising the technology of Argon in double phase for dark matter detection. Though it never actually performed a physics run, a technical run was taken in 2011, to characterise the detector response

  10. Operation of a GERDA phase I prototype detector in liquid argon and nitrogen

    International Nuclear Information System (INIS)

    A GERDA phase I prototype detector, consisting of a bare non-enriched high-purity (HP) p-type germanium diode mounted in a low mass holder has been operated both in liquid nitrogen and liquid argon. Because of its high density, liquid argon has been selected as cryogenic liquid and shield for GERDA experiment. The testing of this detector assembly has been carried out in the underground detector laboratory at LNGS, and at the detector manufacturer. The best resolution achieved is 2.2 keV FWHM at 1.332 MeV, which is the same as the resolution measured in a standard test cryostat. The long-term measurements with the prototype detector are performed in liquid argon. Up to now, 38 thermal cycles have been carried out with this detector. The operations, measurements and results of the prototype detector testing are summarized. (orig.)

  11. Lattice gas model for fragmentation from argon on scandium to gold on gold

    CERN Document Server

    Das-Gupta, S; Gupta, Subal Das; Pan, Jicai

    1995-01-01

    The recent fragmentation data for central collisions of Gold on Gold are even qualitatively different from those for central collisions of Argon on Scandium. The latter can be fitted with a lattice gas model calculation. Effort is made to understand why the model fails for Gold on Gold. The calculation suggests that the large Coulomb interaction which is operative for the larger system is responsible for this discrepancy. This is demonstrated by mapping the lattice gas model to a molecular dynamics calculation for disassembly. This mapping is quite faithful for Argon on Scandium but deviates strongly for Gold on Gold. The molecular dynamics calculation for disassembly reproduces the characteristics of the fragmentation data for both Gold on Gold and Argon on Scandium.

  12. Theoretical and experimental comparisons of Gamble 2 argon gas puff experiments

    International Nuclear Information System (INIS)

    A one-dimensional radiative MHD analysis of an imploding argon gas puff plasma is performed. The calculations are set up to approximate the conditions of a series of argon gas puff experiments that were carried out on the NRL Gamble II generator. Annular gas puffs (2.5 cm diameter) are imploded with a 1.2-MA peak driving current for different initial argon mass loadings. Comparisons are made with the experimental results for implosion times, K, L-shell x-ray emission, and energy coupled from the generator to the plasma load. The purpose of these calculations is to provide a foundation from which a variety of physical phenomena which influence the power and total energy of the x-ray emission can be analyzed. Comparisons with similar experimental and theoretical results for aluminum plasmas are discussed

  13. Atomistic-Continuum Hybrid Simulation of Heat Transfer between Argon Flow and Copper Plates

    CERN Document Server

    Mao, Yijin; Chen, C L

    2016-01-01

    A simulation work aiming to study heat transfer coefficient between argon fluid flow and copper plate is carried out based on atomistic-continuum hybrid method. Navier-Stokes equations for continuum domain are solved through the Pressure Implicit with Splitting of Operators (PISO) algorithm, and the atom evolution in molecular domain is solved through the Verlet algorithm. The solver is validated by solving Couette flow and heat conduction problems. With both momentum and energy coupling method applied, simulations on convection of argon flows between two parallel plates are performed. The top plate is kept as a constant velocity and has higher temperature, while the lower one, which is modeled with FCC copper lattices, is also fixed but has lower temperature. It is found that, heat transfer between argon fluid flow and copper plate in this situation is much higher than that at macroscopic when the flow is fully developed.

  14. Argon: Systematic Review on Neuro- and Organoprotective Properties of an “Inert” Gas

    Directory of Open Access Journals (Sweden)

    Anke Höllig

    2014-10-01

    Full Text Available Argon belongs to the group of noble gases, which are regarded as chemically inert. Astonishingly some of these gases exert biological properties and during the last decades more and more reports demonstrated neuroprotective and organoprotective effects. Recent studies predominately use in vivo or in vitro models for ischemic pathologies to investigate the effect of argon treatment. Promising data has been published concerning pathologies like cerebral ischemia, traumatic brain injury and hypoxic ischemic encephalopathy. However, models applied and administration of the therapeutic gas vary. Here we provide a systematic review to summarize the available data on argon’s neuro- and organoprotective effects and discuss its possible mechanism of action. We aim to provide a summary to allow further studies with a more homogeneous setting to investigate possible clinical applications of argon.

  15. Surface modification of poly (vinyl chloride) by long-distance and direct argon RF plasma

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper reports the effects of long- distance and direct argon radio frequency (RF) plasma surface treatment on polyvinyl chloride (PVC) films in terms of changes in surface wettability and surface chemistry. The surface properties are characterized by the water contact angle measurement, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The mechanism is further analyzed and the role of all kinds of active species, e.g. electrons, ions and free radicals involved in plasma surface modification is further evaluated. Results show that the long-distance and direct RF plasma treatments modify the PVC surface in morphology and composition, and both modifications cause surface oxidation of PVC films, in the forming of functional groups enhancing polymer wettability. The effect of the long-distance argon RF plasma is more notable. This suggests that long-distance argon RF plasma could restrain the ion and electron eroding effect and enhance free radical reaction.

  16. The effects of accelerated heavy nuclei of neon and argon on mammalian cells in culture

    International Nuclear Information System (INIS)

    The survival of human T-1 kidney cells in high-energy neon (400MeV/nucleon) and argon (500MeV/nucleon) beams has been studied at the Berkeley Bevalac. Cells were plated in monolayers on glass and studied at different residual-range values. The survival curves depend on LET and on particle velocity. The effectiveness of the beams increases as the range decreases, except for argon beams with very low range values, where the effectiveness decreases again. The 'oxygen effect' is high at high particle energies (2.6 for neon and 2.4 for argon); it decreases to values between 1.1 and 1.3 near the Bragg peak. (author)

  17. Synodic and semiannual oscillations of argon-40 in the lunar exosphere

    Science.gov (United States)

    Hodges, R. Richard; Mahaffy, Paul R.

    2016-01-01

    The neutral mass spectrometer on the Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft collected a trove of exospheric data, including a set of high-quality measurements of radiogenic 40Ar over a period of 142 days. Data synthesis studies, using well-established exosphere simulation tools, show that the LADEE argon data are consistent with an exosphere-regolith interaction that is dominated by adsorption and that the desorption process generates the Armand distribution of exit velocities. The synthesis work has uncovered an apparent semiannual oscillation of argon that is consistent with temporal sequestration in the seasonal cold traps created at the poles by the obliquity of the Moon. In addition, the LADEE data provide new insight into the pristine nature of lunar regolith, its spatially varying sorption properties, and the influence of sorption processes on the synodic oscillation of the argon exosphere.

  18. Atomistic Simulation of Properties of Ultra-thin Layer of Liquid Argon Compressed Between Diamond Surfaces

    Directory of Open Access Journals (Sweden)

    A.V. Khomenko

    2016-03-01

    Full Text Available Using the method of classical molecular dynamics we investigate the properties of ultrathin film of liquid argon, which consists of one or two layers of molecules and is confined by two atomically smooth crystalline diamond surfaces. The aim of the research is validating the use of rigid surfaces and one of the available models of the argon molecule. We study the behavior of the equilibrium and dynamic characteristics of the system. It is shown that at increasing external load the transition of film in the solid-like state occurs, which is indicated by the behavior of the velocity autocorrelation function of argon molecules, reduction of the magnitude of the diffusion coefficient and the shear viscosity increase. The organization of molecules in layers and the presence of their in-plane ordering are revealed. The dependences of the kinetic friction force on time and load are obtained. The results are compared with experimental data.

  19. Coherent and incoherent Thomson scattering on an argon/hydrogen microwave plasma torch with transient behaviour

    Science.gov (United States)

    Obrusník, A.; Synek, P.; Hübner, S.; van der Mullen, J. J. A. M.; Zajíčková, L.; Nijdam, S.

    2016-10-01

    A new method of processing time-integrated coherent Thomson scattering spectra is presented, which provides not only the electron density and temperature but also information about the transient behaviour of the plasma. Therefore, it is an alternative to single-shot Thomson scattering measurements as long as the scattering is coherent. The method is applied to a microwave plasma torch operating in argon or a mixture of argon with hydrogen at atmospheric pressure. Electron densities up to 8\\cdot {{10}21} m-3 (ionization degree above 10-3) were observed, which is more than two times higher than presented in earlier works on comparable discharges. Additionally, a parametric study with respect to the argon/hydrogen ratio and the input power was carried out and the results are discussed together with earlier Stark broadening measurements on the same plasma.

  20. Ionic Wind Phenomenon and Charge Carrier Mobility in Very High Density Argon Corona Discharge Plasma

    Science.gov (United States)

    Nur, M.; Bonifaci, N.; Denat, A.

    2014-04-01

    Wind ions phenomenon has been observed in the high density argon corona discharge plasma. Corona discharge plasma was produced by point to plane electrodes and high voltage DC. Light emission from the recombination process was observed visually. The light emission proper follow the electric field lines that occur between point and plane electrodes. By using saturation current, the mobilities of non-thermal electrons and ions have been obtained in argon gas and liquid with variation of density from 2,5 1021 to 2 1022 cm-3. In the case of ions, we found that the behaviour of the apparent mobility inversely proportional to the density or follow the Langevin variation law. For non-thermal electron, mobility decreases and approximately follows a variation of Langevin type until the density <= 0,25 the critical density of argon.

  1. Operation of a high purity germanium crystal in liquid argon as a Compton suppressed radiation spectrometer

    CERN Document Server

    Orrell, J L; Amsbaugh, J F; Doe, P J; Hossbach, T W; Orrell, John L.; Aalseth, Craig E.; Amsbaugh, John F.; Doe, Peter J.; Hossbach, Todd W.

    2007-01-01

    A high purity germanium crystal was operated in liquid argon as a Compton suppressed radiation spectrometer. Spectroscopic quality resolution of less than 1% of the full-width half maximum of full energy deposition peaks was demonstrated. The construction of the small apparatus used to obtain these results is reported. The design concept is to use the liquid argon bath to both cool the germanium crystal to operating temperatures and act as a scintillating veto. The scintillation light from the liquid argon can veto cosmic-rays, external primordial radiation, and gamma radiation that does not fully deposit within the germanium crystal. This technique was investigated for its potential impact on ultra-low background gamma-ray spectroscopy. This work is based on a concept initially developed for future germanium-based neutrinoless double-beta decay experiments.

  2. DarkSide-50 WIMP search results with low radioactivity argon

    Science.gov (United States)

    Xiang, Xin; DarkSide Collaboration

    2016-03-01

    Located at the Laboratori Nazionali del Gran Sasso, DarkSide-50 is the first physics detector of the DarkSide dark matter search program. The experiment features a dual-phase Time Projection Chamber as the WIMP detector, surrounded by an organic liquid-scintillator neutron veto and a water-Cherenkov muon detector. We report the results from the first use of low radioactivity argon extracted from underground sources in a dark matter search. We have determined that underground argon is depleted in 39Ar by a factor (1 . 4 +/- 0 . 2) ×103 relative to atmospheric argon whose 39Ar activity is 1 bq/kg. The underground argon is also found to contain (2 . 05 +/- 0 . 13) mBq/kg of 85Kr. We find no evidence for dark matter in the form of WIMPs in 70.9 live-days of data with a fiducial mass of (36 . 9 +/- 0 . 6) kg. When combined with our preceding search with an atmospheric argon target, we set a 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2 . 0 ×10-44 cm2 (8 . 6 ×10-44 cm2, 8 . 0 ×10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2, 10 TeV/c2). DS-50 will continue dark matter search with the underground argon target for a total of 3 years. See also the DS-50 presentations by E. Edkins and G. Koh.

  3. Calculation of ion energy distributions of argon excimer ions generated in helicon plasma

    Institute of Scientific and Technical Information of China (English)

    Fang Tong-Zhen; Jiang Nan; Wang Long

    2005-01-01

    A program is developed to calculate the ion energy distributions (IEDs) of Ar2+ making use of a simplified kinetic model with a combination of Monte Carlo method. Several coefficients are used to realize good match between the calculated and measured results. Some important assumptions are confirmed: argon excimer ions have short lifetime,hence they are formed in a short range before the collecting electrode. The excimer ions that encounter collisions will be discarded because they turn to other ion species after they collide with argon atoms. From the calculated results some plasma parameters such as the cross section or neutral density in discharge could be evaluated.

  4. Transport coefficients of helium-argon mixture based on ab initio potential.

    Science.gov (United States)

    Sharipov, Felix; Benites, Victor J

    2015-10-21

    The viscosity, thermal conductivity, diffusion coefficient, and thermal diffusion factor of helium-argon mixtures are calculated for a wide range of temperature and for various mole fractions up to the 12th order of the Sonine polynomial expansion with an ab initio intermolecular potential. The calculated values for these transport coefficients are compared with other data available in the open literature. The comparison shows that the obtained transport coefficients of helium-argon mixture have the best accuracy for the moment. PMID:26493894

  5. Heat Transfer During Evaporation of Cesium From Graphite Surface in an Argon Environment

    Directory of Open Access Journals (Sweden)

    Bespala Evgeny

    2016-01-01

    Full Text Available The article focuses on discussion of problem of graphite radioactive waste formation and accumulation. It is shown that irradiated nuclear graphite being inalienable part of uranium-graphite reactor may contain fission and activation products. Much attention is given to the process of formation of radioactive cesium on the graphite element surface. It is described a process of plasma decontamination of irradiated graphite in inert argon atmosphere. Quasi-one mathematical model is offered, it describes heat transfer process in graphite-cesium-argon system. Article shows results of calculation of temperature field inside the unit cell. Authors determined the factors which influence on temperature change.

  6. Evolution of precipitate in nickel-base alloy 718 irradiated with argon ions at elevated temperature

    Science.gov (United States)

    Jin, Shuoxue; Luo, Fengfeng; Ma, Shuli; Chen, Jihong; Li, Tiecheng; Tang, Rui; Guo, Liping

    2013-07-01

    Alloy 718 is a nickel-base superalloy whose strength derives from γ'(Ni3(Al,Ti)) and γ″(Ni3Nb) precipitates. The evolution of the precipitates in alloy 718 irradiated with argon ions at elevated temperature were examined via transmission electron microscopy. Selected-area electron diffraction indicated superlattice spots disappeared after argon ion irradiation, which showing that the ordered structure of the γ' and γ″ precipitates became disordered. The size of the precipitates became smaller with the irradiation dose increasing at 290 °C.

  7. A 20-Liter Test Stand with Gas Purification for Liquid Argon Research

    CERN Document Server

    Li, Yichen; Tang, Wei; Joshi, Jyoti; Qian, Xin; Diwan, Milind; Kettell, Steve; Morse, William; Rao, Triveni; Stewart, James; Tsang, Thomas; Zhang, Lige

    2016-01-01

    We describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). This system utilizes a simple, cost-effective gas argon (GAr) purification to achieve ultra-high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. A gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.

  8. Pulse Compression by Filamentation in Argon with an Acoustic Optical Programmable Dispersive Filter for Predispersion Compensation

    Institute of Scientific and Technical Information of China (English)

    CHEN Xiao-Wei; JIANG Yong-Liang; LENG Yu-Xin; LIU Jun; GE Xiao-Chun; LI Ru-Xin; XU Zhi-Zhan

    2006-01-01

    @@ We have experimentally demonstrated pulses 0.4 mJ in duration smaller than 12 fs with an excellent spatial beam profile by self-guided propagation in argon. The original 52fs pulses from the chirped pulsed amplification laser system are first precompressed to 32 fs by inserting an acoustic optical programmable dispersive filter instrument into the laser system for spectrum reshaping and dispersion compensation, and the pulse spectrum is subsequently broadened by filamentation in an argon cell. By using chirped mirrors for post-dispersion compensation, the pulses are successfully compressed to smaller than 12fs.

  9. The Discovery of Argon in Comet C/1995 O1 (Hale-Bopp)

    CERN Document Server

    Stern, S A; Festou, M C; Parker, J W; A'Hearn, M F; Wilkinson, E; Gladstone, G R

    2000-01-01

    On 30.14 March 1997 we observed the EUV spectrum of the bright comet C/1995 O1 (Hale-Bopp) at the time of its perihelion, using our EUVS sounding rocket telescope/spectrometer. The spectra reveal the presence H Ly beta, O+, and, most notably, Argon. Modelling of the retrieved Ar production rates indicates that comet Hale-Bopp is enriched in Ar relative to cosmogonic expectations. This in turn indicates that Hale-Bopp's deep interior has never been exposed to the 35-40 K temperatures necessary to deplete the comet's primordial argon supply.

  10. Physiological responses of Vigna radiata L. to nitrogen and argon+ laser irradiation - Short Communication

    International Nuclear Information System (INIS)

    The effect of nitrogen laser (337.1 nm) and argon+ laser (514.5 nm) irradiation on physiological responses in the green gram seedlings was studied. The shoot and root lengths and fresh and dry weights of the seedlings increased with 30 min exposure to nitrogen laser and 5 min exposure to Argon+ laser. Protein content was maximum with 20 min exposure to N laser and 5 min exposure to Ar+ laser, while DNA and RNA contents were maximum at 5 min exposure with both the laser treatments

  11. Inner-shell Annihilation of Positrons in Argon, Iron and Copper Atoms

    CERN Document Server

    Abdel-Raouf, M A; El-Bakry, S Y

    2007-01-01

    The annihilation parameters of positrons with electrons in different shells of Argon, Iron and Copper atoms are calculated below the positronium (Ps) formation thresholds. Quite accurate ab initio calculations of the bound state wavefunctions of Argon, Iron and Copper orbitals are obtained from Cowan computer code. A least-squares variational method (LSVM) is used for determining the wavefunction of the positrons. The program is employed for calculating the s-wave partial cross sections of positrons scattered by Iron and Copper atoms. Our results of the effective charge are compared with available experimental and theoretical ones. --

  12. Application of argon laser LAK-1 for therapy in selected blood vessel diseases

    Science.gov (United States)

    Szymanczyk, Jacek; Golebiowska, Aleksandra; Michalska, I.; Nowakowski, Wlodzimierz

    1995-03-01

    Argon laser was applied in 172 patients with various vascular disorders and epidermal nevi. The best therapeutical results were obtained in facial telangiectasia and in cavernous hemangiomas, in which there was a complete or almost complete regression. In capillary facial hemangiomas in 49 patients (79%) clearing of 50% to 75% was obtained, and in epidermal nevi the full regression was in 4 (44%) of the cases, and 50% regression in 4 (44%). In telangiectasia of the lower limbs the results were not satisfactory. We stress that cavernous, and capillary hemangiomas, as well as facial telangiectasia are an indication for the argon laser therapy.

  13. Performance of the Electronic Readout of the ATLAS Liquid Argon Calorimeters

    CERN Document Server

    Abreu, H; Aleksa, M; Aperio Bella, L; Archambault, JP; Arfaoui, S; Arnaez, O; Auge, E; Aurousseau, M; Bahinipati, S; Ban, J; Banfi, D; Barajas, A; Barillari, T; Bazan, A; Bellachia, F; Beloborodova, O; Benchekroun, D; Benslama, K; Berger, N; Berghaus, F; Bernat, P; Bernier, R; Besson, N; Binet, S; Blanchard, JB; Blondel, A; Bobrovnikov, V; Bohner, O; Boonekamp, M; Bordoni, S; Bouchel, M; Bourdarios, C; Bozzone, A; Braun, HM; Breton, D; Brettel, H; Brooijmans, G; Caputo, R; Carli, T; Carminati, L; Caughron, S; Cavalleri, P; Cavalli, D; Chareyre, E; Chase, RL; Chekulaev, SV; Chen, H; Cheplakov, A; Chiche, R; Citterio, M; Cojocaru, C; Colas, J; Collard, C; Collot, J; Consonni, M; Cooke, M; Copic, K; Costa, GC; Courneyea, L; Cuisy, D; Cwienk, WD; Damazio, D; Dannheim, D; De Cecco, S; De La Broise, X; De La Taille, C; de Vivie, JB; Debennerot, B; Delagnes, E; Delmastro, M; Derue, F; Dhaliwal, S; Di Ciaccio, L; Doan, O; Dudziak, F; Duflot, L; Dumont-Dayot, N; Dzahini, D; Elles, S; Ertel, E; Escalier, M; Etienvre, AI; Falleau, I; Fanti, M; Farooque, T; Favre, P; Fayard, Louis; Fent, J; Ferencei, J; Fischer, A; Fournier, D; Fournier, L; Fras, M; Froeschl, R; Gadfort, T; Gallin-Martel, ML; Gibson, A; Gillberg, D; Gingrich, DM; Göpfert, T; Goodson, J; Gouighri, M; Goy, C; Grassi, V; Gray, J; Guillemin, T; Guo, B; Habring, J; Handel, C; Heelan, L; Heintz, H; Helary, L; Henrot-Versille, S; Hervas, L; Hobbs, J; Hoffman, J; Hostachy, JY; Hoummada, A; Hrivnac, J; Hrynova, T; Hubaut, F; Huber, J; Iconomidou-Fayard, L; Iengo, P; Imbert, P; Ishmukhametov, R; Jantsch, A; Javadov, N; Jezequel, S; Jimenez Belenguer, M; Ju, XY; Kado, M; Kalinowski, A; Kar, D; Karev, A; Katsanos, I; Kazarinov, M; Kerschen, N; Kierstead, J; Kim, MS; Kiryunin, A; Kladiva, E; Knecht, N; Kobel, M; Koletsou, I; König, S; Krieger, P; Kukhtin, V; Kuna, M; Kurchaninov, L; Labbe, J; Lacour, D; Ladygin, E; Lafaye, R; Laforge, B; Lamarra, D; Lampl, W; Lanni, F; Laplace, S; Laskus, H; Le Coguie, A; Le Dortz, O; Le Maner, C; Lechowski, M; Lee, SC; Lefebvre, M; Leonhardt, K; Lethiec, L; Leveque, J; Liang, Z; Liu, C; Liu, T; Liu, Y; Loch, P; Lu, J; Ma, H; Mader, W; Majewski, S; Makovec, N; Makowiecki, D; Mandelli, L; Mangeard, PS; Mansoulie, B; Marchand, JF; Marchiori, G; Martin, D; Martin-Chassard, G; Martin dit Latour, B; Marzin, A; Maslennikov, A; Massol, N; Matricon, P; Maximov, D; Mazzanti, M; McCarthy, T; McPherson, R; Menke, S; Meyer, JP; Ming, Y; Monnier, E; Mooshofer, P; Neganov, A; Niedercorn, F; Nikolic-Audit, I; Nugent, IM; Oakham, G; Oberlack, H; Ocariz, J; Odier, J; Oram, CJ; Orlov, I; Orr, R; Parsons, JA; Peleganchuk, S; Penson, A; Perini, L; Perrodo, P; Perrot, G; Perus, A; Petit, E; Pisarev, I; Plamondon, M; Poffenberger, P; Poggioli, L; Pospelov, G; Pralavorio, P; Prast, J; Prudent, X; Przysiezniak, H; Puzo, P; Quentin, M; Radeka, V; Rajagopalan, S; Rauter, E; Reimann, O; Rescia, S; Resende, B; Richer, JP; Ridel, M; Rios, R; Roos, L; Rosenbaum, G; Rosenzweig, H; Rossetto, O; Roudil, W; Rousseau, D; Ruan, X; Rudert, A; Rusakovich, N; Rusquart, P; Rutherfoord, J; Sauvage, G; Savine, A; Schaarschmidt, J; Schacht, P; Schaffer, A; Schram, M; Schwemling, P; Seguin Moreau, N; Seifert, F; Serin, L; Seuster, R; Shalyugin, A; Shupe, M; Simion, S; Sinervo, P; Sippach, W; Skovpen, K; Sliwa, R; Soukharev, A; Spano, F; Stavina, P; Straessner, A; Strizenec, P; Stroynowski, R; Talyshev, A; Tapprogge, S; Tarrade, F; Tartarelli, GF; Teuscher, R; Tikhonov, Yu; Tocut, V; Tompkins, D; Thompson, P; Tisserant, S; Todorov, T; Tomasz, F; Trincaz-Duvoid, S; Trinh, Thi N; Trochet, S; Trocme, B; Tschann-Grimm, K; Tsionou, D; Ueno, R; Unal, G; Urbaniec, D; Usov, Y; Voss, K; Veillet, JJ; Vincter, M; Vogt, S; Weng, Z; Whalen, K; Wicek, F; Wilkens, H; Wingerter-Seez, I; Wulf, E; Yang, Z; Ye, J; Yuan, L; Yurkewicz, A; Zarzhitsky, P; Zerwas, D; Zhang, H; Zhang, L; Zhou, N; Zimmer, J; Zitoun, R; Zivkovic, L

    2010-01-01

    The ATLAS detector has been designed for operation at the Large Hadron Collider at CERN. ATLAS includes electromagnetic and hadronic liquid argon calorimeters, with almost 200,000 channels of data that must be sampled at the LHC bunch crossing frequency of 40 MHz. The calorimeter electronics calibration and readout are performed by custom electronics developed specifically for these purposes. This paper describes the system performance of the ATLAS liquid argon calibration and readout electronics, including noise, energy and time resolution, and long term stability, with data taken mainly from full-system calibration runs performed after installation of the system in the ATLAS detector hall at CERN.

  14. Experimental Measurement for Shock Velocity-Mass Velocity Relationship of Liquid Argon Up to 46 GPa

    Institute of Scientific and Technical Information of China (English)

    孟川民; 施尚春; 董石; 杨向东; 谭华; 经福谦

    2003-01-01

    Shock properties of liquid argon were measured in the shock pressure up to 46 GPa by employing the two-stage light gas gun. Liquid nitrogen was used as coolant liquid. The cryogenic target system has been improved to compare with the previous work. Shock velocities were measured with self-shorting electrical probes. Impactor velocities were measured with an electrical-magnetic induction system. Mass velocities were obtained by mean of shock impedance matching method. The experimental data shows that the slope of experimental Hugoniot curve of liquid argon begins to decrease above 30 GPa.

  15. Intermolecular interaction potentials of methane-argon complex calculated using LDA approaches

    Institute of Scientific and Technical Information of China (English)

    Bai Yu-Lin; Chen Xiang-Rong; Zhou Xiao-Lin; Yang Xiang-Dong; Wang Hai-Yan

    2004-01-01

    The intermolecular interaction potential for methane-argon complex is calculated by local density approximation (LDA) approaches. The calculated potential has a minimum when the intermolecular distance of methane-argon complex is 6.75 a.u.; the corresponding depth of the potential is 0.0163eV which has good agreement with experimental data. We also have made a nonlinear fitting of our results for the Lennard-Jones (12-6) potential function and obtain that V(R) = 143794365.332/R12 - 3032.093/R6 (R in a.u. and V(R) in eV).

  16. Ablation of Barrett’s esophagus using the second-generation argon plasma coagulation

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective To investigate the efficacy and safety of the second-generation argon plasma coagulation (VIO APC) in ablation of Barrett’s esophagus. Methods Eighteen patients with Barrett’s esophagus (12 males, median age of 55 years, median length of 2.1 cm,1 low-grade dysplasia, 13 cases of short segment Barrett’s esophagus) received VIO APC, which was performed at a power setting of 40W and argon gas flow at 1.5-2.0 L/min, "forced" mode, in 1-3 sessions (mean 1.3). All the patients received treatment with hi...

  17. Research of On-line Analytical Method of Trace Oxygen and Water in Argon

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Metal sodium has an active chemical quality. When it is used as a coolant in a fast neutron reactor, it must be protected by a cover gas argon for safety operation of the reactor. But oxygen and water in argon can produce chemical reaction with sodium. Then sodium hydroxide, sodium oxide and hydrogen can be produced. This will be harmful to the safety operation of reactor. The purpose of controlling a level of impurity in the cover gas is for controlling a level of impurity in sodium. The research is to find an on-line determining method and a sampling system to monitor

  18. ArgonCube: a novel, fully-modular approach for the realization of large-mass liquid argon TPC neutrino detectors

    CERN Document Server

    Amsler, C; Asaadi, J; Auger, M; Barbato, F; Bay, F; Bishai, M; Bleiner, D; Borgschulte, A; Bremer, J; Cavus, E; Chen, H; De Geronimo, G; Ereditato, A; Fleming, B; Goldi, D; Hanni, R; Kose, U; Kreslo, I; La Mattina, F; Lanni, F; Lissauer, D; Luthi, M; Lutz, P; Marchionni, A; Mladenov, D; Nessi, M; Noto, F; Palamara, O; Raaf, J L; Radeka, V; Rudolph Von Rohr, Ch; Smargianaki, D; Soderberg, M; Strauss, Th; Weber, M; Yu, B; Zeller, G P; Zeyrek, M; CERN. Geneva. SPS and PS Experiments Committee; SPSC

    2015-01-01

    The Liquid Argon Time Projection Chamber is a prime candidate detector for future neutrino oscillation physics experiments, underground neutrino observatories and proton decay searches. A large international project based on this technology is currently being considered at the future LBNF facility in the United States on the very large mass scale of 40 kton. In this document, following the long standing R&D work conducted over the last years in several laboratories in Europe and in the United States, we intend to propose a novel Liquid Argon TPC approach based on a fully-modular, innovative design, the ArgonCube. The related R&D work will proceed along two main directions; one aimed at on the assessment of the proposed modular detector design, the other on the exploitation of new signal readout methods. Such a strategy will provide high performance while being cost-effective and robust at the same time. According to our plans, we will firstly realize a detector prototype hosted in a cryostat that is a...

  19. 40 CFR 63.10686 - What are the requirements for electric arc furnaces and argon-oxygen decarburization vessels?

    Science.gov (United States)

    2010-07-01

    ... Hazardous Air Pollutants for Area Sources: Electric Arc Furnace Steelmaking Facilities Standards and Compliance Requirements § 63.10686 What are the requirements for electric arc furnaces and argon-oxygen... arc furnaces and argon-oxygen decarburization vessels? 63.10686 Section 63.10686 Protection...

  20. Numerical Simulation of the Thermal Conductivity of Thermal Insulation Pipe by Vacuum and High Pressure Argon Pre-filled

    Institute of Scientific and Technical Information of China (English)

    2014-01-01

    [Abstract]By analyzing the insulation effect of argon-filled tubing and vacuum-insulated tubing before and after hydrogen permeation respectively, a conclusion can be drawn that the insulated tubing filled with high pressure argon is better than the vacuum insulated tubing considering the lifetime and heat insulation effect.

  1. Ex vivo and in vivo neuroprotection induced by argon when given after an excitotoxic or ischemic insult.

    Directory of Open Access Journals (Sweden)

    Hélène N David

    Full Text Available In vitro studies have well established the neuroprotective action of the noble gas argon. However, only limited data from in vivo models are available, and particularly whether postexcitotoxic or postischemic argon can provide neuroprotection in vivo still remains to be demonstrated. Here, we investigated the possible neuroprotective effect of postexcitotoxic-postischemic argon both ex vivo in acute brain slices subjected to ischemia in the form of oxygen and glucose deprivation (OGD, and in vivo in rats subjected to an intrastriatal injection of N-methyl-D-aspartate (NMDA or to the occlusion of middle-cerebral artery (MCAO. We show that postexcitotoxic-postischemic argon reduces OGD-induced cell injury in brain slices, and further reduces NMDA-induced brain damage and MCAO-induced cortical brain damage in rats. Contrasting with its beneficial effect at the cortical level, we show that postischemic argon increases MCAO-induced subcortical brain damage and provides no improvement of neurologic outcome as compared to control animals. These results extend previous data on the neuroprotective action of argon. Particularly, taken together with previous in vivo data that have shown that intraischemic argon has neuroprotective action at both the cortical and subcortical level, our findings on postischemic argon suggest that this noble gas could be administered during but not after ischemia, i.e. before but not after reperfusion has occurred, in order to provide cortical neuroprotection and to avoid increasing subcortical brain damage. Also, the effects of argon are discussed as regards to the oxygen-like chemical, pharmacological, and physical properties of argon.

  2. Photoionization cross-sections for atoms and ions of aluminum, silicon, and argon.

    Science.gov (United States)

    Chapman, R. D.; Henry, R. J. W.

    1972-01-01

    Photoionization cross sections for all levels belonging to the configurations of atoms and ions of aluminum, silicon, and argon have been calculated using Hartree-Fock bound-electron wave functions and close-coupling approximation free-electron wave functions. The results are presented in the form of a computationally convenient interpolation formula and should find wide astrophysical application.

  3. Liquid Argon Dielectric Breakdown Studies with the MicroBooNE Purification System

    Energy Technology Data Exchange (ETDEWEB)

    Acciarri, R. [Fermilab; Carls, B. [Fermilab; James, C. [Fermilab; Johnson, B. [Fermilab; Jostlein, H. [Fermilab; Lockwitz, S. [Fermilab; Lundberg, B. [Fermilab; Raaf, J. L. [Fermilab; Rameika, R. [Fermilab; Rebel, B. [Fermilab; Zeller, G. P. [Fermilab; Zuckerbrot, M. [Fermilab

    2014-11-04

    The proliferation of liquid argon time projection chamber detectors makes the characterization of the dielectric properties of liquid argon a critical task. To improve understanding of these properties, a systematic study of the breakdown electric field in liquid argon was conducted using a dedicated cryostat connected to the MicroBooNE cryogenic system at Fermilab. An electrode sphere-plate geometry was implemented using spheres with diameters of 1.3 mm, 5.0 mm, and 76 mm. The MicroBooNE cryogenic system allowed measurements to be taken at a variety of electronegative contamination levels ranging from a few parts-per-million to tens of parts-per-trillion. The cathode-anode distance was varied from 0.1 mm to 2.5 cm. The results demonstrate a geometric dependence of the electric field strength at breakdown. This study is the first time that the dependence of the breakdown field on stressed cathode area has been shown for liquid argon.

  4. Resonance ionization spectroscopy of argon, krypton, and xenon using vacuum ultraviolet light

    International Nuclear Information System (INIS)

    Resonant, single-photon excitation of ground state inert gases requires light in the vacuum ultraviolet spectral region. This paper discusses methods for generating this light. Efficient schemes for ionizing argon, krypton, and xenon using resonant, stepwise single-photon excitation are presented

  5. A calculation of internal kinetic energy and polarizability of compressed argon from the statistical atom model

    NARCIS (Netherlands)

    Seldam, C.A. ten; Groot, S.R. de

    1952-01-01

    From Jensen's and Gombás' modification of the statistical Thomas-Fermi atom model, a theory for compressed atoms is developed by changing the boundary conditions. Internal kinetic energy and polarizability of argon are calculated as functions of pressure. At 1000 atm. an internal kinetic energy of a

  6. First Observation of Low Energy Electron Neutrinos in a Liquid Argon Time Projection Chamber

    CERN Document Server

    Acciarri, R; Asaadi, J; Baller, B; Bolton, T; Bromberg, C; Cavanna, F; Church, E; Edmunds, D; Ereditato, A; Farooq, S; Fitzpatrick, R S; Fleming, B; Hackenburg, A; Horton-Smith, G; James, C; Lang, K; Luo, X; Mehdiyev, R; Page, B; Palamara, O; Rebel, B; Schukraft, A; Scanavini, G; Soderberg, M; Spitz, J; Szelc, A M; Weber, M; Yang, T; Zeller, G P

    2016-01-01

    Liquid argon time projection chambers (LArTPCs) produce remarkable fidelity in the observation of neutrino interactions. The superior capabilities of such detectors to reconstruct the spatial and calorimetric information of neutrino events have made them the detectors of choice in a number of experiments, specifically those looking to observe electron neutrino ($\

  7. Operation of a GERDA phase I prototype detector in liquid argon

    International Nuclear Information System (INIS)

    A non-enriched high-purity (HP) p-type germanium diode has been operated in a low mass holder in liquid nitrogen and liquid argon. Because of the shielding and scintillation properties of liquid argon, GERDA experiment is planned to use it as a cryogenic fluid shield. Therefore, the long-term measurements with the bare detector are performed in liquid argon. The testing of the prototype detector and the preparation of the enriched detectors for GERDA phase I are being carried out in the GERDA underground Detector Laboratory (GDL) at LNGS. The phase I prototype detector assembly is being operated since beginning of 2006 to study detector handling protocols, detector assembly performance and detector assembly stability. 45 warming and cooling cyclings have been carried out. Since February 8 2007, the prototype detector is continuously operated in liquid argon under varying irradiation conditions. The operations, measurements and results of the prototype detector testing as well as the status of the phase I enriched detectors are summarized

  8. Liquid Argon Dielectric Breakdown Studies with the MicroBooNE Purification System

    CERN Document Server

    Acciarri, R; James, C; Johnson, B; Jostlein, H; Lockwitz, S; Lundberg, B; Raaf, J L; Rameika, R; Rebel, B; Zeller, G P; Zuckerbrot, M

    2014-01-01

    The proliferation of liquid argon time projection chamber detectors makes the characterization of the dielectric properties of liquid argon a critical task. To improve understanding of these properties, a systematic study of the breakdown electric field in liquid argon was conducted using a dedicated cryostat connected to the MicroBooNE cryogenic system at Fermilab. An electrode sphere-plate geometry was implemented using spheres with diameters of 1.3 mm, 5.0 mm, and 76 mm. The MicroBooNE cryogenic system allowed measurements to be taken at a variety of electronegative contamination levels ranging from a few parts-per-million to tens of parts-per- trillion. The cathode-anode distance was varied from 0.1 mm to 2.5 cm. The results demonstrate a geometric dependence of the electric field strength at breakdown. This study is the first time that the dependence of the breakdown field on stressed cathode area has been shown for liquid argon.

  9. Common versus noble Bacillus subtilis differentially responds to air and argon gas plasma.

    Science.gov (United States)

    Winter, Theresa; Bernhardt, Jörg; Winter, Jörn; Mäder, Ulrike; Schlüter, Rabea; Weltmann, Klaus-Dieter; Hecker, Michael; Kusch, Harald

    2013-09-01

    The applications of low-temperature plasma are not only confined to decontamination and sterilization but are also found in the medical field in terms of wound and skin treatment. For the improvement of already established and also for new plasma techniques, in-depth knowledge on the interactions between plasma and microorganism is essential. In an initial study, the interaction between growing Bacillus subtilis and argon plasma was investigated by using a growth chamber system suitable for low-temperature gas plasma treatment of bacteria in liquid medium. In this follow-up investigation, a second kind of plasma treatment-namely air plasma-was applied. With combined proteomic and transcriptomic analyses, we were able to investigate the plasma-specific stress response of B. subtilis toward not only argon but also air plasma. Besides an overlap of cellular responses due to both argon and air plasma treatment (DNA damage and oxidative stress), a variety of gas-dependent cellular responses such as growth retardation and morphological changes were observed. Only argon plasma treatments lead to a phosphate starvation response whereas air plasma induced the tryptophan operon implying damage by photooxidation. Biological findings were supported by the detection of reactive plasma species by optical emission spectroscopy and Fourier transformed infrared spectroscopy measurements. PMID:23794223

  10. Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon

    CERN Document Server

    Agnes, P; Alexander, T; Alton, A K; Asner, D M; Back, H O; Baldin, B; Biery, K; Bocci, V; Bonfini, G; Bonivento, W; Bossa, M; Bottino, B; Brigatti, A; Brodsky, J; Budano, F; Bussino, S; Cadeddu, M; Cadoni, M; Calaprice, F; Canci, N; Candela, A; Caravati, M; Cariello, M; Carlini, M; Catalanotti, S; Cavalcante, P; Chepurnov, A; Cicalò, C; Cocco, A G; Covone, G; D'Angelo, D; D'Incecco, M; Davini, S; De Cecco, S; De Deo, M; De Vincenzi, M; Derbin, A; Devoto, A; Di Eusanio, F; Di Pietro, G; Dionisi, C; Edkins, E; Empl, A; Fan, A; Fiorillo, G; Fomenko, K; Forster, G; Franco, D; Gabriele, F; Galbiati, C; Giagu, S; Giganti, C; Giovanetti, G K; Goretti, A M; Granato, F; Gromov, M; Guan, M; Guardincerri, Y; Hackett, B R; Herner, K; Hughes, D; Humble, P; Hungerford, E V; Ianni, A; James, I; Johnson, T N; Jollet, C; Keeter, K; Kendziora, C L; Koh, G; Korablev, D; Korga, G; Kubankin, A; Li, X; Lissia, M; Loer, B; Lombardi, P; Longo, G; Ma, Y; Machulin, I N; Mandarano, A; Mari, S M; Maricic, J; Marini, L; Martoff, C J; Meregaglia, A; Meyers, P D; Milincic, R; Miller, J D; Montanari, D; Monte, A; Mount, B J; Muratova, V N; Musico, P; Napolitano, J; Agasson, A Navrer; Odrowski, S; Oleinik, A; Orsini, M; Ortica, F; Pagani, L; Pallavicini, M; Pantic, E; Parmeggiano, S; Pelczar, K; Pelliccia, N; Pocar, A; Pordes, S; Pugachev, D A; Qian, H; Randle, K; Ranucci, G; Razeti, M; Razeto, A; Reinhold, B; Renshaw, A L; Rescigno, M; Riffard, Q; Romani, A; Rossi, B; Rossi, N; Rountree, D; Sablone, D; Saggese, P; Sands, W; Savarese, C; Schlitzer, B; Segreto, E; Semenov, D A; Shields, E; Singh, P N; Skorokhvatov, M D; Smirnov, O; Sotnikov, A; Stanford, C; Suvorov, Y; Tartaglia, R; Tatarowicz, J; Testera, G; Tonazzo, A; Trinchese, P; Unzhakov, E V; Verducci, M; Vishneva, A; Vogelaar, B; Wada, M; Walker, S; Wang, H; Wang, Y; Watson, A W; Westerdale, S; Wilhelmi, J; Wojcik, M M; Xiang, X; Xiao, X; Xu, J; Yang, C; Zhong, W; Zhu, C; Zuzel, G

    2016-01-01

    Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a $\\sim$2% increase in light yield compared to alphas in no field.

  11. Neutral gas temperature estimates and metastable resonance energy transfer for argon-nitrogen discharges

    International Nuclear Information System (INIS)

    Rovibrational spectroscopy band fitting of the nitrogen (N2) second positive system is a technique used to estimate the neutral gas temperature of N2 discharges, or atomic discharges with trace amounts of a N2 added. For mixtures involving argon and N2, resonant energy transfer between argon metastable atoms (Ar*) and N2 molecules may affect gas temperature estimates made using the second positive system. The effect of Ar* resonance energy transfer is investigated here by analyzing neutral gas temperatures of argon-N2 mixtures, for N2 percentages from 1% to 100%. Neutral gas temperature estimates are higher than expected for mixtures involving greater than 5% N2 addition, but are reasonable for argon with less than 5% N2 addition when compared with an analytic model for ion-neutral charge exchange collisional heating. Additional spatiotemporal investigations into neutral gas temperature estimates with 10% N2 addition demonstrate that although absolute temperature values may be affected by Ar* resonant energy transfer, spatiotemporal trends may still be used to accurately diagnose the discharge

  12. Three-body dispersion contributions to the thermodynamic properties and effective pair interactions in liquid argon

    NARCIS (Netherlands)

    Hoef, van der Martin A.; Madden, Paul A.

    1999-01-01

    The contributions of three-body triple dipole and dipole-dipole-quadrupole dispersion interactions to the thermodynamic properties of liquid argon are examined, using a recently introduced simulation scheme which contains an explicit, quantum mechanical representation of the underlying electronic st

  13. Arc Root Motions in an Argon-Hydrogen Direct-Current Plasma Torch at Reduced Pressure

    Institute of Scientific and Technical Information of China (English)

    HUANG He-Ji; PAN Wen-Xia; WU Cheng-Kang

    2008-01-01

    Arc root motions in generating dc argon hydrogen plasma at reduced pressure are optically observed using a high-speed video camera. The time resolved angular position of the arc root attachment point is measured and analysed. The arc root movement is characterized as a chaotic and jumping motion along the circular direction on the anode surface.

  14. Simulations of geometrically pinched argon plasmas using an extended one-dimensional model

    NARCIS (Netherlands)

    K.T.A.L. Burm,; W. J. Goedheer,; D.C. Schram,

    2001-01-01

    The subject of this paper is the modelling of a wall-stabilized cylinder symmetric cascaded are which is to be used as a high-density plasma source. To enhance the ion flux emerging from cascaded are argon plasmas the confining wall can be changed into a nozzle geometry. Such pinched geometries incr

  15. CT assessment of liver hemodynamics in patients with hepatocellular carcinoma after argon-helium cryoablation

    Institute of Scientific and Technical Information of China (English)

    Xue-Jia Hao; Jin-Ping Li; Hui-Jie Jiang; Da-Qing Li; Zai-Sheng Ling

    2013-01-01

    BACKGROUND: Assessment  of  tumor  response  after  argon-helium  cryoablation  is  critical  in  guiding  future  therapy  for unresectable  hepatocellular  carcinoma.  This  study  aimed  to evaluate  liver  hemodynamics  in  hepatocellular  carcinoma after  argon-helium  cryoablation  with  computed  tomography perfusion. METHODS: The  control  group  comprised  40  volunteers without liver disease.  The  experimental  group  was  composed of  15  patients  with  hepatocellular  carcinoma  treated  with argon-helium  cryoablation.  Computed  tomography  perfusion parameters were measured: hepatic blood flow, hepatic blood volume,  mean  transit  time,  permeability  of  capillary  vessel surface, hepatic arterial fraction, hepatic arterial perfusion, and hepatic portal perfusion. RESULTS: After  treatment,  in  the  tumor  foci,  permeability of  capillary  vessel  surface  was  higher,  and  hepatic  blood flow,  hepatic  blood  volume,  hepatic  arterial  fraction,  and hepatic  arterial  perfusion  values  were  lower  (P0.05). CONCLUSION: Computed tomography perfusion can evaluate tumor response after argon-helium cryoablation.

  16. Neutral gas temperature estimates and metastable resonance energy transfer for argon-nitrogen discharges

    Energy Technology Data Exchange (ETDEWEB)

    Greig, A., E-mail: amelia.greig@anu.edu.au; Charles, C.; Boswell, R. W. [Space Plasma, Power and Propulsion Laboratory, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 2601 (Australia)

    2016-01-15

    Rovibrational spectroscopy band fitting of the nitrogen (N{sub 2}) second positive system is a technique used to estimate the neutral gas temperature of N{sub 2} discharges, or atomic discharges with trace amounts of a N{sub 2} added. For mixtures involving argon and N{sub 2}, resonant energy transfer between argon metastable atoms (Ar*) and N{sub 2} molecules may affect gas temperature estimates made using the second positive system. The effect of Ar* resonance energy transfer is investigated here by analyzing neutral gas temperatures of argon-N{sub 2} mixtures, for N{sub 2} percentages from 1% to 100%. Neutral gas temperature estimates are higher than expected for mixtures involving greater than 5% N{sub 2} addition, but are reasonable for argon with less than 5% N{sub 2} addition when compared with an analytic model for ion-neutral charge exchange collisional heating. Additional spatiotemporal investigations into neutral gas temperature estimates with 10% N{sub 2} addition demonstrate that although absolute temperature values may be affected by Ar* resonant energy transfer, spatiotemporal trends may still be used to accurately diagnose the discharge.

  17. MeV Argon ion beam generation with narrow energy spread

    CERN Document Server

    Xu, Jiancai; Shen, Baifei; Zhang, Hui; Li, Shun; Yu, Yong; Li, Jinfeng; Lu, Xiaoming; Wang, Cheng; Wang, Xinliang; Liang, Xiaoyan; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan

    2016-01-01

    Laser driven particle acceleration has shown remarkable progresses in generating multi-GeV electron bunches and 10s of MeV ion beams based on high-power laser facilities. Intense laser pulse offers the acceleration field of 1012 Volt per meter, several orders of magnitude larger than that in conventional accelerators, enabling compact devices. Here we report that a highly-collimated argon ion beam with narrow energy spread is produced by irradiating a 45-fs fully-relativistic laser pulse onto an argon cluster target. The highly-charged (Argon ion with charge state of 16+) heavy ion beam has a minimum absolute energy spread of 0.19 MeV per nucleon at the energy peak of 0.39 MeV per nucleon. we identify a novel scheme from particle-in-cell simulations that greatly reduces the beam energy spread. The laser-driven intense plasma wakefield has a strong modulation on the ion beam in a way that the low energy part is cut off. The pre-accelerated argon ion beam from Coulomb explosion thus becomes more mono-energetic ...

  18. Test beam results of a stereo preshower integrated in the liquid argon accordion calorimeter

    CERN Document Server

    Davis, R; Greenious, G; Kitching, P; Olsen, B; Pinfold, James L; Rodning, N L; Boos, E; Zhautykov, B O; Aubert, Bernard; Bazan, A; Beaugiraud, B; Boniface, J; Colas, Jacques; Eynard, G; Jézéquel, S; Le Flour, T; Linossier, O; Nicoleau, S; Sauvage, G; Thion, J; Van den Plas, D; Wingerter-Seez, I; Zitoun, R; Zolnierowski, Y; Chmeissani, M; Fernández, E; Garrido, L; Martínez, M; Padilla, C; Citterio, M; Gordon, H A; Lissauer, D; Ma, H; Makowiecki, D S; Radeka, V; Rahm, David Charles; Rescia, S; Stephani, D; Takai, H; Baisin, L; Berset, J C; Chevalley, J L; Gianotti, F; Gildemeister, O; Marin, C P; Nessi, Marzio; Poggioli, Luc; Richter, W; Vuillemin, V; Baze, J M; Delagnes, E; Gosset, L G; Lavocat, P; Lottin, J P; Mansoulié, B; Meyer, J P; Renardy, J F; Schwindling, J; Simion, S; Taguet, J P; Teiger, J; Walter, C; Collot, J; de Saintignon, P; Hostachy, J Y; Mahout, G; Barreiro, F; Del Peso, J; García, J; Hervás, L; Labarga, L; Romero, P; Scheel, C V; Chekhtman, A; Cousinou, M C; Dargent, P; Dinkespiler, B; Etienne, F; Fassnacht, P; Fouchez, D; Martin, L; Miotto, A; Monnier, E; Nagy, E; Olivetto, C; Tisserant, S; Battistoni, G; Camin, D V; Cavalli, D; Costa, G; Cozzi, L; Fedyakin, N N; Ferrari, A; Mandelli, L; Mazzanti, M; Perini, L; Resconi, S; Sala, P R; Beaudoin, G; Depommier, P; León-Florián, E; Leroy, C; Roy, P; Augé, E; Breton, D; Chase, Robert L; Chollet, J C; de La Taille, C; Fayard, Louis; Fournier, D; González, J; Hrisoho, A T; Jacquier, Y; Merkel, B; Nikolic, I A; Noppe, J M; Parrour, G; Pétroff, P; Puzo, P; Richer, J P; Schaffer, A C; Seguin-Moreau, N; Serin, L; Tisserand, V; Veillet, J J; Vichou, I; Canton, B; David, J; Genat, J F; Imbault, D; Le Dortz, O; Savoy-Navarro, Aurore; Schwemling, P; Eek, L O; Lund-Jensen, B; Söderqvist, J; Astbury, Alan; Keeler, Richard K; Lefebvre, M; Robertson, S; White, J

    1998-01-01

    This paper describes the construction of an integrated preshower within the RD3 liquid argon accordion calorimeter. It has a stereo view which enables the measurement of two transverse coordinates. The prototype was tested at CERN with electrons, photons and muons to validate its capability to work at LHC ( Energy resolution, impact point resolution, angular resolution, $\\pi^o$/$\\gamma$ rejection ).

  19. Low energy (e,2e) ionization of Argon in the equal energy sharing geometry

    CERN Document Server

    Mazevet, S; Langlois, J M; Tweed, R J; Robaux, O; Tannous, C; Fakhreddine, K

    2002-01-01

    Quantum Defect theory is a well established theoretical concept in modern spectroscopy. We show that this approach is useful in electron impact ionization problems where state of the art theoretical methods are presently restricted mostly to simple atomic targets. For the well documented Argon ionization case in equal energy sharing geometry the approach suggested leads to significant improvements compared to previous calculations.

  20. Evaporation characteristics of thin film liquid argon in nano-scale confinement: A molecular dynamics study

    Science.gov (United States)

    Hasan, Mohammad Nasim; Shavik, Sheikh Mohammad; Rabbi, Kazi Fazle; Haque, Mominul

    2016-07-01

    Molecular dynamics simulation has been carried out to explore the evaporation characteristics of thin liquid argon film in nano-scale confinement. The present study has been conducted to realize the nano-scale physics of simultaneous evaporation and condensation inside a confined space for a three phase system with particular emphasis on the effect of surface wetting conditions. The simulation domain consisted of two parallel platinum plates; one at the top and another at the bottom. The fluid comprised of liquid argon film at the bottom plate and vapor argon in between liquid argon and upper plate of the domain. Considering hydrophilic and hydrophobic nature of top and bottom surfaces, two different cases have been investigated: (i) Case A: Both top and bottom surfaces are hydrophilic, (ii) Case B: both top and bottom surfaces are hydrophobic. For all cases, equilibrium molecular dynamics (EMD) was performed to reach equilibrium state at 90 K. Then the lower wall was set to four different temperatures such as 110 K, 120 K, 130 K and 140 K to perform non-equilibrium molecular dynamics (NEMD). The variation of temperature and density as well as the variation of system pressure with respect to time were closely monitored for each case. The heat fluxes normal to top and bottom walls were estimated and discussed to illuminate the effectiveness of heat transfer in both hydrophilic and hydrophobic confinement at various boundary temperatures of the bottom plate.

  1. Darkside-20k: A 20 ton Liquid Argon Dark Matter Experiment

    Science.gov (United States)

    Back, Henning; Darkside-20k Collaboration

    2016-03-01

    The Darkside-20k detector is the next step in the Darkside dark matter search program at the Laboratori Nazionali del Gran Sasso in Italy. The Darkside detectors have grown in fiducial mass starting with 10kg in Darkside10, to 50 kg in Darkside50, and finally a proposed 20,000 kg fiducial mass, Darkside20k. The Darkside detectors are dual-phase argon TPCs that combine the very powerful scintillation pulse-shape analysis and ionization information to discriminate against background events. Two unique aspects to the Darkside program is the use of an external neutron veto based on borated liquid scintillator, and the use of low radioactivity argon from underground sources as the target. Argon from the atmosphere has an 39Ar activity of 1Bq/kg, which would be the limiting background, but the underground argon is essentially free of 39Ar. Additionally, the detector is placed in a water Cherenkov muon veto. Combining all these techniques allows Darkside-20k to achieve a background-free 100 t-yr exposure accumulated in a 5 yr run. Darkside-20k is expected to start operations in 2020 with data taking starting in 2021, and will be sensitive to WIMP-nucleon interaction cross sections of 1×10-47 cm2 (1x10-46 cm2) for WIMPs of 1 TeV/c2 (10 TeV/c2) mass.

  2. A liquid argon calorimeter prototype for forward region at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Artamonov, A. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Epstein, V. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Gorbunov, P. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Jemanov, V. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Khovansky, V. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Kuchenkov, A. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Kruchinin, S. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Maslennikov, A. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Rjabinin, M. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Shatalov, P. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Vinogradov, V. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Zaitsev, V. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Zeldovich, S. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation); Zuckerman, I. [Institut Teoreticheskoj i Ehksperimental`noj Fiziki, Moscow (Russian Federation)

    1996-02-21

    We report on the design and on beam test results of a liquid argon calorimeter prototype. This technology was proposed as an option for the forward region of an experiment at the future Large Hadron Collider (LHC) at CERN. The measurements were performed using electrons from the ITEP PS with an energy range of 1 to 5 GeV. (orig.).

  3. Ionization EM calorimetry with accordion electrodes and liquid krypton or argon

    Energy Technology Data Exchange (ETDEWEB)

    Radeka, V.

    1993-11-01

    The results of a study and tests of a liquid krypton/argon electromagnetic calorimeter with accordion electrode structure are briefly summarized. This includes the calorimeter response to electrons and muons, energy, pointing and timing resolution, and a measurement by multiple sampling. The electrode layout with fine segmentation is illustrated.

  4. Pollution of liquid argon after neutron irradiation measured at SARA: summary of raw data

    CERN Document Server

    Andrieux, M L; de Saintignon, P; Ferrari, A; Hostachy, J Y; Martin, P; Wielers, M; Belymam, A; Hoummada, A; Merkel, B; Puzo, P M; Sauvage, D

    1998-01-01

    The SARA fast neutron facility has been used to irradiate various pieces of materials due to be used in the ATLAS electromagnetic calorimeter, immersed in a liquid argon cryostat. The subsequent pollution was measured. The raw data have been summarized in this paper.

  5. The Ashima/MIT Mars GCM and argon in the martian atmosphere

    Science.gov (United States)

    Lian, Yuan; Richardson, Mark I.; Newman, Claire E.; Lee, Christopher; Toigo, Anthony D.; Mischna, Michael A.; Campin, Jean-Michel

    2012-04-01

    We investigate the ability of modern general circulation models (GCMs) to simulate transport in the martian atmosphere using measurements of argon as a proxy for the transport processes. Argon provides the simplest measure of transport as it is a noble gas with no sinks or sources on seasonal timescales. Variations in argon result solely from 'freeze distillation', as the atmosphere condenses at the winter poles, and from atmospheric transport. Comparison of all previously published models when rescaled to a common definition of the argon enhancement factor (EF) suggest that models generally do a poor job in predicting the peak enhancement in southern winter over the winter pole - the time when the capability of the model transport approaches are most severely tested. Despite observed peak EF values of ˜6, previously published model predictions peaked at EF values of only 2-3. We introduce a new GCM that provides a better treatment of mass conservation within the dynamical core, includes more sophisticated tracer transport approaches, and utilizes a cube-sphere grid structure thus avoiding the grid-point convergence problem at the pole that exists for most current Mars GCMs. We describe this model - the Ashima Research/Massachusetts Institute of Technology Mars General Circulation Model (Ashima/MIT Mars GCM) and use it to demonstrate the significant sensitivity of peak EF to the choices of transport approach for both tracers and heat. We obtain a peak EF of 4.75 which, while over 50% higher than any prior model, remains well short of the observed value. We show that the polar EF value in winter is primarily determined by the competition between two processes: (1) mean meridional import of lower-latitude air not enriched in argon and (2) the leakage of enriched argon out of the polar column by eddies in the lowest atmospheric levels. We suggest possibilities for improving GCM representation of the CO2 cycle and the general circulation that may further improve the

  6. Cryogenic separation of oxygen-argon mixture in natural air samples for isotopic and molecular ratios

    Science.gov (United States)

    Habeeb Rahman, Keedakkadan; Abe, Osamu

    2014-05-01

    The discovery of mass independent isotope fractionation in oxygen during the formation of ozone in the stratosphere has initiated a wide application in isotope geochemistry field. Separation of oxygen-argon mixture has become the foundation of high precision analysis of Δ17O and δ(O2/Ar) for geochemical applications. Here we present precise and simplified cryogenic separation of argon oxygen mixture from the atmospheric and dissolved air using 30/60 mesh 5A molecular sieve zeolite. A pioneer study of this method was conducted by Thiemens and Meagher in 1984. The column which is made of glass tube contains about 1.1 grams of molecular sieve zeolite and both ends of column was filled with glass wools. The experimental set up was tested for different combination of molecular sieves and slurry temperatures. We found the most efficient condition for the separation was at a column temperature of -103°C. For complete transfer of O2 and Ar mixture usually takes in 15-20 minutes time. The isotopic ratios of oxygen were analyzed using mass spectrometer (Thermo Fischer Delta Plus) relative to reference oxygen-argon mixture at 3V of m/z 32 for both sample and reference side. The signals of m/z 28, 32, and 40 were measured by dynamically to determine oxygen -argon ratio and to check nitrogen contamination. Repeated measurements of atmospheric air yielded a reproducibility (SE n=80) of 0.006, 0.004 and 0.19‰ for δ17O, δ18O and δO2/Ar respectively. The isotopic and molecular fractionation of argon- oxygen mixture during gas adsorption and desorption while using molecular sieve under liquid nitrogen temperature was studied. We have established a linear relationship governing the effect of 13X and 5A molecular sieves on molecular fractionation. And suggested the use of single 1/8" pellet 13X molecular sieve provided a negligible fractionation.

  7. Size Effect on Transport Properties of Gaseous Argon: A Molecular Dynamics Simulation Study

    International Nuclear Information System (INIS)

    We have carried out a series of equilibrium molecular dynamics (EMD) simulations of gaseous argon at 273.15 K and 1.00 atm for the calculation of transport properties as a function of the number of argon molecules (N). While the diffusion coefficients (D) of gaseous argon approach to the experimental measure with increasing N, the viscosities (η) and thermal conductivities (λ) obtained for N = 432 are unreliable due to the high fluctuation of the time correlation functions and those for N = 1728 are rather acceptable. Increasing further to N = 6912 has improved the MD results a little closer to the experimental measures for η and λ. Both the EMD results for η and λ for N = 6912 underestimate the experimental measures and it is not expected that the more increasing N makes the closer results to the experimental measures. One possible explanation for the large disagreement between MD results and the experimental measures for η and λ may be due to the use of LJ parameters which were used for liquid argon. In a recent study, we have examined the Green-Kubo formula for the calculation of transport properties (diffusion coefficient, viscosity, and thermal conductivity) of noble gases (He, Ne, Ar, Kr, and Xe) by carrying out a series of equilibrium molecular dynamics (EMD) simulations for the system of N=1728 at 273.15 K and 1.00 atm.1 While the diffusion coefficients (D) of noble gases were obtained through the original Green-Kubo formula, the viscosities (η) and thermal conductivities (λ) were obtained by utilizing the revised Green-Kubo formulas. The structural and dynamic properties of gaseous argon are completely different from those of liquid argon at 94.4 K and 1.374 g/cm3. The results for transport properties (D, η, and λ) at 273.15 K and 1.00 atm obtained from our EMD simulations are in general agreement with the experimental data and superior to the rigorous results of the kinetic theory

  8. Operating Instructions for the Cryogenics in the Liquid Argon Detector at CIEMAT; Operacion de la Criogenia del Detector de Argon Liquido del CIEMAT

    Energy Technology Data Exchange (ETDEWEB)

    Romero, L.; Leal, M. D.; Prado, M. del; Ramirez, J. L.

    2009-12-19

    Ciemat has wide experience in designing and developing gaseous particle detectors. It has taken part in the building of experiments for CERN accelerators, constructing shares of the muon chambers for L3 experiment in LEP and CMS experiment in LHC. Recently, new concepts for particle detectors have been developed, as a natural evolution from the ones built at Ciemat. These new radiation detectors use liquefied noble gases as active media. A testing system for these kind of liquefied argon detectors has been built at Ciemat, and includes a supporting cryogenic system for the liquefaction and maintenance of the liquid argon needed for operating the detector. This document describes the technical features of this cryogenic system. Besides the documentation of the cryogenic system, this technical report can be of help for the management and upgrading of the detector. As well as an introduction, the report includes the following chapters: The second one is a description of the cryogenics and gas systems. The third chapter shows the controlling electronics. The fourth chapter deals with the important topic that is security, its systems and protocols. The fifth describes the cryogenic operations possible in this equipment. The report is completed with diagrams, schemes, pictures and tables for the easier management of the setup. (Author)

  9. Compilation of electron collision excitation cross sections for neutral argon; Compilacion de resultados de secciones eficaces de excitacion para niveles del Argon neutro

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, F.

    1993-07-01

    The present work presents a compilation and critical analysis of the available data on electron collision excitation cross sections for neutral Argon levels. This study includes: 1.- A detailed description in intermediate coupling for all the levels belonging the 20 configurations 3p5 ns (n=4to 12), np(n=4to8) and nd(n=3to8)of neutral Argon. 2.- Calculation of the electron collision excitation cross sections in Born and Born-Oppenheimer-Ochkur approximations for all the levels in the 14 configurations 3p5 ns (n=4 to 7), np (n=4 to 7) and nd (n=3 to 8). 3.- comparison and discussion of the compiled data. These are the experimental and theoretical values available from the literature, and those from this work. 4.- Analysis of the regularities and systematic behaviors in order to determine which values can be considered more reliable. It is show that the concept of one electron cross section results quite useful for this purpose. In some cases it has been possible to obtain in this way approximate analytical expressions interpolating the experimental data. 5.- All the experimental and theoretical values studied are graphically presented and compared. 6.- The last part of the work includes a listing of several general purpose programs for Atomic Physics calculations developed for this work. (Author) 35 refs.

  10. Surface modification of fluorosilicone acrylate RGP contact lens via low-temperature argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Yin Shiheng [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China); Analytical and Testing Center, South China University of Technology, Guangzhou 510640 (China); Wang Yingjun [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China); Ren Li [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China)], E-mail: psliren@scut.edu.cn; Zhao Lianna [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China); Kuang Tongchun [Analytical and Testing Center, South China University of Technology, Guangzhou 510640 (China); Chen Hao [Wenzhou Medical College, Wenzhou 325035 (China)], E-mail: chenhao823@mail.wz.zj.cn; Qu Jia [Wenzhou Medical College, Wenzhou 325035 (China)

    2008-11-15

    A fluorosilicone acrylate rigid gas permeable (RGP) contact lens was modified via argon plasma to improve surface hydrophilicity and resistance to protein deposition. The influence of plasma treatment on surface chemical structure, hydrophilicity and morphology of RGP lens was investigated by X-ray photoelectron spectrometer (XPS), contact angle measurements and scanning electron microscope (SEM), respectively. The contact angle results showed that the hydrophilicity of the contact lens was improved after plasma treatment. XPS results indicated that the incorporation of oxygen-containing groups on surface and the transformation of silicone into hydrophilic silicate after plasma treatment are the main reasons for the surface hydrophilicity improvement. SEM results showed that argon plasma with higher power could lead to surface etching.

  11. Novel Diamond Films Synthesis Strategy: Methanol and Argon Atmosphere by Microwave Plasma CVD Method Without Hydrogen.

    Science.gov (United States)

    Yang, Li; Jiang, Caiyi; Guo, Shenghui; Zhang, Libo; Gao, Jiyun; Peng, Jinhui; Hu, Tu; Wang, Liang

    2016-12-01

    Diamond thin films are grown on silicon substrates by only using methanol and argon mixtures in microwave plasma chemical vapor deposition (MPCVD) reactor. It is worth mentioning that the novel strategy makes the synthesis reaction works smoothly without hydrogen atmosphere, and the substrates temperature is only 500 °C. The evidence of surface morphology and thickness under different time is obtained by characterizing the samples using scanning electron microscopy (SEM). X-ray diffractometer (XRD) spectrum reveals that the preferential orientation of (111) plane sample is obtained. The Raman spectra indicate that the dominant component of all the samples is a diamond. Moreover, the diamond phase content of the targeted films was quantitatively analyzed by X-ray photoelectron spectroscopy (XPS) method, and the surface roughness of diamond films was investigated by atomic force microscope (AFM). Meanwhile, the possible synthesis mechanism of the diamond films in methanol- and argon-mixed atmosphere was discussed. PMID:27644241

  12. Nanometer-scale sharpening and surface roughening of ZnO nanorods by argon ion bombardment

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, Shyamal, E-mail: shyamal@iitbbs.ac.in [School of Basic Sciences, Indian Institute of Technology, Bhubaneswar 751013 (India); Behera, Akshaya K. [School of Basic Sciences, Indian Institute of Technology, Bhubaneswar 751013 (India); Banerjee, Amarabha; Tribedi, Lokesh C. [Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400005 (India); Som, Tapobrata [Institute of Physics, Sachivalaya Marg, Bhubaneswar 751005 (India); Ayyub, Pushan, E-mail: pushan@tifr.res.in [Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400005 (India)

    2012-07-01

    We report the effects of exposing a hydrothermally grown, single crystalline ZnO nanorod array to a beam of 50 keV argon ions at room temperature. High resolution electron microscopy reveals that the ion bombardment results in a nanometer-scale roughening of the nanorod sidewalls, which were almost atomically flat in the pristine sample. Ion bombardment further causes the flat, Almost-Equal-To 100 nm diameter nanorod tips to get sharpened to ultrafine points less than 10 nm across. While tip sharpening is attributed to preferential sputtering, the formation of crystalline surface protuberances can be ascribed to surface instability due to curvature dependent sputtering and surface diffusion under argon-ion bombardment. Both the nanoscale roughening as well as the tip sharpening are expected to favorably impact a wide variety of applications, such as those involving catalysis, gas sensing, solar cells, field emission and gas discharge.

  13. Pressure-Induced Argon Insertion into an Auxetic Small Pore Zeolite

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y.; Hriljac, J; Vogt, T

    2010-01-01

    We report that natrolite, Na{sub 16}Al{sub 16}Si{sub 24}O{sub 48} {center_dot} 16H{sub 2}O, a small pore auxetic zeolite can incorporate significant amounts of Argon under moderate pressure- and temperature conditions resulting in Na{sub 16}Al{sub 16}Si{sub 24}O{sub 80} {center_dot} 16H{sub 2}O {center_dot} 6Ar. This material has a {approx}6.5% larger unit cell than natrolite at ambient conditions and its structure is related to Na{sub 16}Al{sub 16}Si{sub 24}O{sub 80} {center_dot} 24H{sub 2}O, an intermediate superhydrated natrolite referred to as para-natrolite. Argon insertion under pressure into auxetic frameworks such as natrolites is an important and overlooked confinement mechanism with potential applications and implications.

  14. Photochemistry of the ozone-water complex in cryogenic neon, argon, and krypton matrixes.

    Science.gov (United States)

    Tsuge, Masashi; Tsuji, Kazuhide; Kawai, Akio; Shibuya, Kazuhiko

    2013-12-12

    The photochemistry of ozone-water complexes and the wavelength dependence of the reactions were studied by matrix isolation FTIR spectrometry in neon, argon, and krypton matrixes. Hydrogen peroxide was formed upon the irradiation of UV light below 355 nm. Quantitative analyses of the reactant and product were performed to evaluate the matrix cage effect of the photoreaction. In argon and krypton matrixes, a bimolecular O((1)D) + H2O → H2O2 reaction was found to occur to form hydrogen peroxide, where the O((1)D) atom generated by the photolysis of ozone diffused in the cryogenic solids to encounter water. In a neon matrix, hydrogen peroxide was generated through intracage photoreaction of the ozone-water complex, indicating that a neon matrix medium is most appropriate to study the photochemistry of the ozone-water complex.

  15. Are the argon metastables important in high power impulse magnetron sputtering discharges?

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J. T., E-mail: tumi@hi.is [Department of Space and Plasma Physics, School of Electrical Engineering, KTH Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Science Institute, University of Iceland, Dunhaga 3, IS-107 Reykjavik (Iceland); Lundin, D.; Minea, T. M. [Laboratoire de Physique des Gaz et Plasmas - LPGP, UMR 8578 CNRS, Université Paris-Sud, 91405 Orsay Cedex (France); Stancu, G. D. [CentraleSupélec, Grande Voie des Vignes, 92295 Chatenay-Malabry Cedex (France); CNRS, UPR 288 Laboratoire EM2C, Grande Voie des Vignes, 92295 Chatenay-Malabry Cedex (France); Brenning, N. [Department of Space and Plasma Physics, School of Electrical Engineering, KTH Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Plasma and Coatings Physics Division, IFM-Materials Physics, Linköping University, SE-581 83 Linköping (Sweden)

    2015-11-15

    We use an ionization region model to explore the ionization processes in the high power impulse magnetron sputtering (HiPIMS) discharge in argon with a titanium target. In conventional dc magnetron sputtering (dcMS), stepwise ionization can be an important route for ionization of the argon gas. However, in the HiPIMS discharge stepwise ionization is found to be negligible during the breakdown phase of the HiPIMS pulse and becomes significant (but never dominating) only later in the pulse. For the sputtered species, Penning ionization can be a significant ionization mechanism in the dcMS discharges, while in the HiPIMS discharge Penning ionization is always negligible as compared to electron impact ionization. The main reasons for these differences are a higher plasma density in the HiPIMS discharge, and a higher electron temperature. Furthermore, we explore the ionization fraction and the ionized flux fraction of the sputtered vapor and compare with recent experimental work.

  16. Radon backgrounds in the DEAP-1 liquid argon based Dark Matter detector

    CERN Document Server

    Amaudruz, P -A; Beltran, B; Boudjemline, K; Caldwell, M G Boulay B Cai T; Chen, M; Chouinard, R; Cleveland, B T; Contreras, D; Dering, K; Duncan, F; Ford, R; Giuliani, R Gagnon F; Golovko, M Gold V V; Gorel, P; Graham, K; Grant, D R; Hakobyan, R; Hallin, A L; Harvey, P; Hearns, C; Jillings, C J; Kuźniak, M; Lawson, I; Li, O; Lidgard, J; Liimatainen, P; Lippincott, W H; Mathew, R; McDonald, A B; McElroy, T; McFarlane, K; McKinsey, D; Muir, A; Nantais, C; Nicolics, K; Nikkel, J; Noble, T; O'Dwyer, E; Olsen, K S; Ouellet, C; Pasuthip, P; Pollmann, T; Rau, W; Retiere, F; Ronquest, M; Skensved, P; Sonley, T; Vázquez-Jáuregui, E; Veloce, L; Ward, M

    2012-01-01

    The DEAP-1 \\SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the DEAP-3600 Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them. The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \\SI{26}{\\micro\\becquerel\\per\\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the final DEAP-1 detector generation is well described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse sh...

  17. ATLAS endcap liquid argon calorimeters. Description and construction of the cryostats

    Energy Technology Data Exchange (ETDEWEB)

    Mace, Guy; Prat, Serge; Veillet, Jean-Jacques [Laboratoire de l' Accelerateur Lineaire IN2P3-CNRS et Universite de Paris-Sud 11, BP 34, F-91898 Orsay Cedex (France)

    2006-05-15

    All forward calorimeters of the ATLAS detector use the same detection technique, energy loss in passive plates, followed by ionisation and charge detection in liquid argon. They are therefore all grouped in the same vessel which must basically support and keep in place the heavy plates and the detection electrodes and maintain liquid argon at cold and stable temperature. Taking into account all the constraints as detailed below, and the overall detector size, 5 meter diameter by 3 meter length this was quite a challenge. The design, construction and tests of these two cryostats, up to their delivery at CERN, are described in this document. These two cryostats are a joint 'in kind' contribution to the Atlas experiment of LAL (Orsay), Max Planck Institute (Muenchen) and Wuppertal University (Wuppertal) and have been designed and built under the responsibility of LAL (Orsay) with contributions of the technical groups of the above institutions and of ATLAS-CERN. (authors)

  18. Two-phase Cryogenic Avalanche Detector with electroluminescence gap operated in argon doped with nitrogen

    CERN Document Server

    Bondar, A; Dolgov, A; Nosov, V; Shekhtman, L; Shemyakina, E; Sokolov, A

    2016-01-01

    A two-phase Cryogenic Avalanche Detector (CRAD) with electroluminescence (EL) gap, operated in argon doped with a minor (49$\\pm$7 ppm) admixture of nitrogen, has been studied. The EL gap was optically read out using cryogenic PMTs located on the perimeter of the gap. We present the results of the measurements of the N$_2$ content, detector sensitivity to X-ray-induced signals, EL gap yield and electron lifetime in the liquid. The detector sensitivity, at a drift field in liquid Ar of 0.6 kV/cm, was measured to be 9 and 16 photoelectrons recorded at the PMTs per keV of deposited energy at 23 and 88 keV respectively. Such two-phase detectors, with enhanced sensitivity to the S2 (ionization-induced) signal, are relevant in the field of argon detectors for dark matter search and low energy neutrino detection.

  19. Experimental study of electric breakdowns in liquid argon at centimeter scale

    CERN Document Server

    Blatter, A; Hsu, C -C; Janos, S; Kreslo, I; Luethi, M; von Rohr, C Rudolf; Schenk, M; Strauss, T; Weber, M S; Zeller, M

    2014-01-01

    In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300 mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  20. Characteristics of a DC discharge with a water cathode in argon

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, S. A.; Shutov, D. A.; Bobkova, E. S.; Rybkin, V. V., E-mail: rybkin@isuct.ru [Ivanovo State University of Chemistry and Technology (Russian Federation)

    2016-01-15

    The characteristics of a dc discharge excited between a metal anode and a water cathode in argon were studied experimentally. The dimensions of the positive column and the electric field in it were measured, and the vibrational temperature in the positive column was determined from the N{sub 2}C{sup 3}Π{sub u} → B{sup 3}Π{sub g} (0–2) emission band. It is shown that the power deposited in the positive column is almost entirely spent on gas heating. The obtained dependence of the reduced electric field on the gas pressure and the ionization frequencies calculated by solving the Boltzmann equation indicate that electrons are lost diffusively, whereas ionization proceeds in a stepwise manner via the lower metastable states of argon atoms.

  1. Adsorption and diffusion of argon confined in ordered and disordered microporous carbons

    International Nuclear Information System (INIS)

    We use a combination of grand canonical Monte Carlo and microcanonical molecular dynamics simulations to study the adsorption and diffusion of argon at 77 K and 120 K confined in previously generated models of a disordered bituminous coal-based carbon, BPL, and an ordered carbon replica of Faujasite zeolite (C-FAU). Both materials exhibit a maximum in the diffusion coefficient as well as anomalous (sub-diffusive) behavior in the mean-squared displacements at short times at some relative pressures. In BPL, the anomalous diffusion occurs at low relative pressures, due to the trapping of argon atoms in small pores. In C-FAU, the anomalous diffusion occurs at high relative pressures, due to competitive diffusion of atoms traveling through windows and constrictions which interconnect the pores. All diffusion eventually tends to Fickian diffusion at longer times.

  2. First results obtained from the Cello liquid argon end cap calorimeters

    International Nuclear Information System (INIS)

    The Cello liquid argon calorimeter is presented in the first part of this thesis. The cryogenic system has to supply three cryostats filled with liquid argon: one cylindrical cryostat of 25 m3 volume contains 2x8 separate modules; each of the two symmetric end cap cryostats contains two half cylindrical modules. Each module in the end cap part consists of 42 layers of lead strips interleaved with 43 full plates. The strips are alternatively vertical, horizontal and circular. In front of the lead calorimeter are 4 planes of copper foils glued on epoxy for dE/dx measurement. The electronics, signal processing and data acquisition system are described. In the second part, the performance and analysis of data measured by the end cap calorimeters are reported: study of Bhabha scattering e+e- → e+e-; preliminary results obtained in two photon physics e+e- → e+e-γγ → e+e-X

  3. Benchmarking TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    CERN Document Server

    Baptista, B; Chiu, C; Conrad, J M; Ignarra, C M; Jones, B J P; Katori, T; Mufson, S

    2012-01-01

    Scintillation light from liquid argon is produced at 128 nm and thus must be shifted to visible wavelengths in light detection systems used for Liquid Argon Time Projection Chambers (LArTPCs). To date, designs have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we show that the response of lightguides coated with TPB in a UV Transmitting (UVT) acrylic matrix is very similar to that of a coating using a polystyrene (PS) matrix. We obtain a factor of three higher light yield than has been previously reported from lightguides. This paper provides information on the response of the lightguides so that these can be modeled in simulations for future LArTPCs. This paper also identifies areas of R&D for potential improvements in the lightguide response

  4. Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector

    CERN Document Server

    Boccone, V; Mavrokoridis, K; Regenfus, C; Amsler, C; Badertscher, A; Bueno, A; Cabrera, H; Carmona-Benitez, M C; Daniel, M; Daw, E J; Degunda, U; Dell'Antone, A; Gendotti, A; Epprecht, L; Horikawa, S; Kaufmann, L; Knecht, L; Laffranchi, M; Lazzaro, C; Lussi, D; Lozano, J; Marchionni, A; Melgarejo, A; Mijakowski, P; Natterer, G; Navas-Concha, S; Otyugova, P; de Prado, M; Przewlocki, P; Resnati, F; Robinson, M; Rochet, J; Romero, L; Rondio, E; Rubbia, A; Spooner, N J C; Strauss, T; Ulbricht, J; Viant, T

    2009-01-01

    To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were deposited by spraying and vacuum evaporation onto specular 3M{\\small\\texttrademark}-foil and diffuse Tetratex{\\small\\textregistered} (TTX) substrates. Light yields of each reflector and TPB coating combination were compared. Reflection coefficients of TPB coated reflectors were independently measured using a spectroradiometer in a wavelength range between 200 and 650~nm. WLS coating on the PMT window was also studied. These measurements were used to define the parameters of the light reflectors of the ArDM experiment. Fifteen large $120\\times 25$~cm$^2$ TTX sheets were coated and assembled in the detector. Measurements...

  5. Tetraphenyl-butadiene films: VUV-Vis optical characterization from room to liquid argon temperature

    Science.gov (United States)

    Francini, R.; Montereali, R. M.; Nichelatti, E.; Vincenti, M. A.; Canci, N.; Segreto, E.; Cavanna, F.; Di Pompeo, F.; Carbonara, F.; Fiorillo, G.; Perfetto, F.

    2013-09-01

    A thin film of Tetraphenyl-butadiene (TPB) deposited onto the surface delimiting the active volume of the detector and/or onto the photosensor's optical window is the most common solution to down convert argon VUV scintillation light in current and planned liquid argon based experiments for dark matter searches and neutrino physics. Characterization of the main features of TPB coatings on different, commonly used substrates is reported, as a result of measurements at the specialized optical metrology labs of ENEA and University of Tor Vergata. Measured features include TPB emission spectra with lineshape and relative intensity variation recorded as a function of the film thickness and for the first time down to LAr temperature, as well as optical reflectance and transmittance spectra of the TPB coated substrates in the wavelength range of the TPB emission.

  6. Improved TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    CERN Document Server

    Moss, Z; Collin, G; Conrad, J M; Jones, B J P; Moon, J; Toups, M; Wongjirad, T

    2014-01-01

    Scintillation light produced in liquid argon (LAr) must be shifted from 128 nm to visible wavelengths in light detection systems used for liquid argon time-projection chambers (LArTPCs). To date, LArTPC light collection systems have employed tetra phenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we report on light guides with improved attenuation lengths above 100 cm when measured in air. This is an important step in the development of meter-scale light guides for future LArTPCs. Improvements come from using a new acrylic-based coating, diamond-polished cast UV transmitting acrylic bars, and a hand-dipping technique to coat the bars.

  7. Some effects of argon and helium upon explosions of carbon monoxide and oxygen

    Science.gov (United States)

    Fiock, Ernst F; Roeder, Carl H

    1937-01-01

    Report presents the results of an investigation conducted to study the effects of the inert gases, argon and helium, upon flame speed and expansion ratio in exploding mixtures of carbon monoxide, oxygen and water.For the particular gas mixtures investigated the results show that: (1) With the possible exception of helium in small amounts the addition of inert gas always produces decreased flame speed and expansion ratio; (2) like volumes of argon and helium have very different effects upon flame speed but practically the same effect upon expansion ratio; and (3) the difference in the effect of these two gases upon speed is independent of the ratio of carbon monoxide to oxygen. A discussion of some possible modes by which inert gases may produce the observed effects is included.

  8. Transpupillary Argon Laser Cyclophotocoagulation in a Refractory Traumatic Glaucoma Patient with Aphakia and Aniridia

    Directory of Open Access Journals (Sweden)

    Umut Duygu Uzunel

    2016-01-01

    Full Text Available We present a case of transpupillary argon laser cyclophotocoagulation (TALC in a patient with traumatic aniridia and aphakia secondary to blunt trauma who had previous bilateral trabeculectomy. Four months after the trauma the patient’s intraocular pressure (IOP rose to 35 mmHg despite topical antiglaucomatous medication. Inferior 180 degrees cyclophotocoagulation was performed with transpupillary argon laser in the first session and his IOP fell to values of 12-17 mmHg. Twelve weeks after TALC, his IOP rose to 22 mmHg and we had to apply TALC to the residual ciliary processes. Seven months later his IOP was 13 mmHg with topical dorzolamide/timolol and latanoprost administration. TALC may be an effective treatment alternative for lowering IOP in patients with visible ciliary processes who do not respond to conventional medical or laser treatment.

  9. Oxidized dahlia-like carbon nanohorns: adsorption of argon, methane and nitrogen

    Science.gov (United States)

    Krungleviciute, Vaiva; Migone, Aldo; Yudasaka, Masako; Iijima, Sumio

    2010-03-01

    Different types of nanohorns, and nanohorn aggregates, can be produced depending on the parameters used during their production. We used a sample consisting mainly of dahlia-like nanohorn aggregates. In the dahlia-like aggregates the individual nanohorns are aligned radially, forming a sphere, with their individual ends protruding from the outer surface of the spherule. Our sample was oxidized by flowing pure oxygen. This treatment opened entry ports into the spaces at the interior of the individual nanohorns. We measured volumetric adsorption isotherms at 77.3 K with argon, methane, and nitrogen. For argon and methane two distinct substeps are present in the adsorption data; the steps for each of these two gases are comparable in size. For nitrogen there is a clear step present at lower adsorbent loadings, and a more gradual growth in the amount adsorbed as saturation is approached.

  10. Influence of dissociative recombination on the LTE of argon high-frequency plasmas at atmospheric pressure

    CERN Document Server

    Sainz, A; García, M C; Calzada, M D; Sainz, Abel; Margot, Joelle; Garcia, Maria Carmen; Calzada, Maria Dolores

    2004-01-01

    This work presents a few preliminary results from a collisional-radiative (CR) model intended to describe an argon microwave (2.45 GHz) plasma at atmospheric pressure. This model aims to investigate the influence of dissociative recombination products on the Saha-Boltzmann plasma equilibrium. The model is tested through comparison with experimental results obtained in an argon plasma column generated by a traveling electromagnetic surface-wave, which is suitable to perform a parametric investigation of the plasma. It is shown that dissociative recombination predominantly populates the 4s levels and the ground state. It is further observed that it strongly influences the population of the levels, specially those of lower energy. However, the higher levels (close to the ionization limit) appear to be in equilibrium whatever the plasma density. This allows assuming that the excitation temperature Texc determined from the upper levels in the atomic system in the Boltzmann-plot is equal to Te.

  11. Liquid Argon Time Projection Chamber research and development in the United States

    Science.gov (United States)

    Baller, B.; Bromberg, C.; Buchanan, N.; Cavanna, F.; Chen, H.; Church, E.; Gehman, V.; Greenlee, H.; Guardincerri, E.; Jones, B.; Junk, T.; Katori, T.; Kirby, M.; Lang, K.; Loer, B.; Marchionni, A.; Maruyama, T.; Mauger, C.; Menegolli, A.; Montanari, D.; Mufson, S.; Norris, B.; Pordes, S.; Raaf, J.; Rebel, B.; Sanders, R.; Soderberg, M.; St. John, J.; Strauss, T.; Szelc, A.; Tope, T.; Touramanis, C.; Thorn, C.; Urheim, J.; Van de Water, R.; Wang, H.; Yu, B.; Zuckerbrot, M.

    2014-05-01

    A workshop was held at Fermilab on March 20-21, 2013 to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in seven topical plenary sessions: i) Argon Purity, ii) Cryogenics, iii) TPC and High Voltage, iv) Electronics, Data Acquisition and Triggering, v) Scintillation Light Detection, vi) Calibration and Test Beams, and vii) Software. This document summarizes the current efforts in each of these areas. It also highlights areas in LArTPC research and development that are common between neutrino experiments and dark matter experiments.

  12. Rotational and Vibrational Temperatures of Atmospheric Double Arc Argon-Nitrogen Plasma

    Institute of Scientific and Technical Information of China (English)

    YAN Jian-Hua; TU Xin; MA Zeng-Yi; CEN Ke-Fa; B.G.Chéron

    2007-01-01

    The spectroscopic technique is employed to study the emission of atmospheric argon-nitrogen plasma jet generated by an original dc double anode plasma torch. The molecular bands of the N(+2) first negative system are observed at the torch exit and chosen to evaluate the rotational and vibrational temperatures in comparison with the simulated spectra. The excitation temperature (Texc≈9600 K) is determined from the Boltzmann plot method. The results show that the rotational, vibrational, electron and kinetic temperatures are in good agreement with one another, which indicates that the core region of atmospheric double arc argon-nitrogen plasma jet at the torch exit is close to the local thermodynamic equilibrium state under our experimental conditions.

  13. Observation of Ω mode electron heating in dusty argon radio frequency discharges

    Energy Technology Data Exchange (ETDEWEB)

    Killer, Carsten; Bandelow, Gunnar; Schneider, Ralf; Melzer, André [Institut für Physik, Ernst-Moritz-Arndt-Universität Greifswald, 17489 Greifswald (Germany); Matyash, Konstantin [Universitätsrechenzentrum, Ernst-Moritz-Arndt-Universität Greifswald, 17489 Greifswald (Germany)

    2013-08-15

    The time-resolved emission of argon atoms in a dusty plasma has been measured with phase-resolved optical emission spectroscopy using an intensified charge-coupled device camera. For that purpose, three-dimensional dust clouds have been confined in a capacitively coupled rf argon discharge with the help of thermophoretic levitation. While electrons are exclusively heated by the expanding sheath (α mode) in the dust-free case, electron heating takes place in the entire plasma bulk when the discharge volume is filled with dust particles. Such a behavior is known as Ω mode, first observed in electronegative plasmas. Furthermore, particle-in-cell simulations have been carried out, which reproduce the trends of the experimental findings. These simulations support previous numerical models showing that the enhanced atomic emission in the plasma can be attributed to a bulk electric field, which is mainly caused by the reduced electrical conductivity due to electron depletion.

  14. Experimental thermal conductivity, thermal diffusivity, and specific heat values for mixtures of nitrogen, oxygen, and argon

    Science.gov (United States)

    Perkins, R. A.; Cieszkiewicz, M. T.

    1991-01-01

    Experimental measurements of thermal conductivity and thermal diffusivity obtained with a transient hot-wire apparatus are reported for three mixtures of nitrogen, oxygen, and argon. Values of the specific heat, Cp, are calculated from these measured values and the density calculated with an equation of state. The measurements were made at temperatures between 65 and 303 K with pressures between 0.1 and 70 MPa. The data cover the vapor, liquid, and supercritical gas phases for the three mixtures. The total reported points are 1066 for the air mixture (78.11 percent nitrogen, 20.97 percent oxygen, and 0.92 percent argon), 1058 for the 50 percent nitrogen, 50 percent oxygen mixture, and 864 for the 25 percent nitrogen, 75 oxygen mixture. Empirical thermal conductivity correlations are provided for the three mixtures.

  15. Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons

    CERN Document Server

    Aad, G; Abdallah, J; Abdelalim, A A; Abdesselam, A; Abdinov, O; Abi, B; Abolins, M; Abramowicz, H; Abreu, H; Acharya, B S; Adams, D L; Addy, T N; Adelman, J; Adorisio, C; Adragna, P; Adye, T; Aefsky, S; Aguilar-Saavedra, J A; Aharrouche, M; Ahlen, S P; Ahles, F; Ahmad, A; Ahmed, H; Ahsan, M; Aielli, G; Akdogan, T; Åkesson, T P A; Akimoto, G; Akimov, A V; Aktas, A; Alam, M S; Alam, M A; Albert, J; Albrand, S; Aleksa, M; Aleksandrov, I N; Alessandria, F; Alexa, C; Alexander, G; Alexandre, G; Alexopoulos, T; Alhroob, M; Aliev, M; Alimonti, G; Alison, J; Aliyev, M; Allport, P P; Allwood-Spiers, S E; Almond, J; Aloisio, A; Alon, R; Alonso, A; Alviggi, M G; Amako, K; Amelung, C; Ammosov, V V; Amorim, A; Amorós, G; Amram, N; Anastopoulos, C; Andeen, T; Anders, C F; Anderson, K J; Andreazza, A; Andrei, V; Anduaga, X S; Angerami, A; Anghinolfi, F; Anjos, N; Antonaki, A; Antonelli, M; Antonelli, S; Antos, J; Antunovic, B; Anulli, F; Aoun, S; Arabidze, G; Aracena, I; Arai, Y; Arce, A T H; Archambault, J P; Arfaoui, S; Arguin, J F; Argyropoulos, T; Arik, E; Arik, M; Armbruster, A J; Arnaez, O; Arnault, C; Artamonov, A; Arutinov, D; Asai, M; Asai, S; Asfandiyarov, R; Ask, S; Åsman, B; Asner, D; Asquith, L; Assamagan, K; Astbury, A; Astvatsatourov, A; Atoian, G; Auerbach, B; Auge, E; Augsten, K; Aurousseau, M; Austin, N; Avolio, G; Avramidou, R; Axen, D; Ay, C; Azuelos, G; Azuma, Y; Baak, M A; Bacci, C; Bach, A; Bachacou, H; Bachas, K; Backes, M; Badescu, E; Bagnaia, P; Bai, Y; Bailey, D C; Bain, T; Baines, J T; Baker, O K; Baker, M D; Baker, S; Baltasar Dos Santos Pedrosa, F; Banas, E; Banerjee, P; Banerjee, S; Banfi, D; Bangert, A; Bansal, V; Baranov, S P; Baranov, S; Barashkou, A; Barber, T; Barberio, E L; Barberis, D; Barbero, M; Bardin, D Y; Barillari, T; Barisonzi, M; Barklow, T; Barlow, N; Barnett, B M; Barnett, R M; Baron, S; Baroncelli, A; Barr, A J; Barreiro, F; Barreiro Guimarães da Costa, J; Barrillon, P; Barros, N; Bartoldus, R; Bartsch, D; Bastos, J; Bates, R L; Batkova, L; Batley, J R; Battaglia, A; Battistin, M; Bauer, F; Bawa, H S; Bazalova, M; Beare, B; Beau, T; Beauchemin, P H; Beccherle, R; Becerici, N; Bechtle, P; Beck, G A; Beck, H P; Beckingham, M; Becks, K H; Bedajanek, I; Beddall, A J; Beddall, A; Bednár, P; Bednyakov, V A; Bee, C; Begel, M; Behar Harpaz, S; Behera, P K; Beimforde, M; Belanger-Champagne, C; Bell, P J; Bell, W H; Bella, G; Bellagamba, L; Bellina, F; Bellomo, M; Belloni, A; Belotskiy, K; Beltramello, O; Ben Ami, S; Benary, O; Benchekroun, D; Bendel, M; Benedict, B H; Benekos, N; Benhammou, Y; Benincasa, G P; Benjamin, D P; Benoit, M; Bensinger, J R; Benslama, K; Bentvelsen, S; Beretta, M; Berge, D; Bergeaas Kuutmann, E; Berger, N; Berghaus, F; Berglund, E; Beringer, J; Bernardet, K; Bernat, P; Bernhard, R; Bernius, C; Berry, T; Bertin, A; Besana, M I; Besson, N; Bethke, S; Bianchi, R M; Bianco, M; Biebel, O; Biesiada, J; Biglietti, M; Bilokon, H; Bindi, M; Binet, S; Bingul, A; Bini, C; Biscarat, C; Bitenc, U; Black, K M; Blair, R E; Blanchard, J B; Blanchot, G; Blocker, C; Blocki, J; Blondel, A; Blum, W; Blumenschein, U; Bobbink, G J; Bocci, A; Boehler, M; Boek, J; Boelaert, N; Böser, S; Bogaerts, J A; Bogouch, A; Bohm, C; Bohm, J; Boisvert, V; Bold, T; Boldea, V; Boldyrev, A; Bondarenko, V G; Bondioli, M; Boonekamp, M; Bordoni, S; Borer, C; Borisov, A; Borissov, G; Borjanovic, I; Borroni, S; Bos, K; Boscherini, D; Bosman, M; Bosteels, M; Boterenbrood, H; Bouchami, J; Boudreau, J; Bouhova-Thacker, E V; Boulahouache, C; Bourdarios, C; Boyd, J; Boyko, I R; Bozovic-Jelisavcic, I; Bracinik, J; Braem, A; Branchini, P; Brandenburg, G W; Brandt, A; Brandt, G; Brandt, O; Bratzler, U; Brau, B; Brau, J E; Braun, H M; Brelier, B; Bremer, J; Brenner, R; Bressler, S; Breton, D; Britton, D; Brochu, F M; Brock, I; Brock, R; Brodbeck, T J; Brodet, E; Broggi, F; Bromberg, C; Brooijmans, G; Brooks, W K; Brown, G; Brubaker, E; Bruckman de Renstrom, P A; Bruncko, D; Bruneliere, R; Brunet, S; Bruni, A; Bruni, G; Bruschi, M; Buanes, T; Bucci, F; Buchanan, J; Buchholz, P; Buckley, A G; Budagov, I A; Budick, B; Büscher, V; Bugge, L; Bulekov, O; Bunse, M; Buran, T; Burckhart, H; Burdin, S; Burgess, T; Burke, S; Busato, E; Bussey, P; Buszello, C P; Butin, F; Butler, B; Butler, J M; Buttar, C M; Butterworth, J M; Byatt, T; Caballero, J; Cabrera Urbán, S; Caforio, D; Cakir, O; Calafiura, P; Calderini, G; Calfayan, P; Calkins, R; Caloba, L P; Caloi, R; Calvet, D; Camarri, P; Cambiaghi, M; Cameron, D; Campabadal Segura, F; Campana, S; Campanelli, M; Canale, V; Canelli, F; Canepa, A; Cantero, J; Capasso, L; Capeans Garrido, M D M; Caprini, I; Caprini, M; Capua, M; Caputo, R; Caracinha, D; Caramarcu, C; Cardarelli, R; Carli, T; Carlino, G; Carminati, L; Caron, B; Caron, S; Carrillo Montoya, G D; Carron Montero, S; Carter, A A; Carter, J R; Carvalho, J; Casadei, D; Casado, M P; Cascella, M; Caso, C; Castaneda Hernadez, A M; Castaneda-Miranda, E; Castillo Gimenez, V; Castro, N; Cataldi, G; Catinaccio, A; Catmore, J R; Cattai, A; Cattani, G; Caughron, S; Cauz, D; Cavalleri, P; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Ceradini, F; Cerqueira, A S; Cerri, A; Cerrito, L; Cerutti, F; Cetin, S A; Cevenini, F; Chafaq, A; Chakraborty, D; Chan, K; Chapman, J D; Chapman, J W; Chareyre, E; Charlton, D G; Chavda, V; Cheatham, S; Chekanov, S; Chekulaev, S V; Chelkov, G A; Chen, H; Chen, S; Chen, T; Chen, X; Cheng, S; Cheplakov, A; Chepurnov, V F; Cherkaoui El Moursli, R; Tcherniatine, V; Chesneanu, D; Cheu, E; Cheung, S L; Chevalier, L; Chevallier, F; Chiarella, V; Chiefari, G; Chikovani, L; Childers, J T; Chilingarov, A; Chiodini, G; Chizhov, M; Choudalakis, G; Chouridou, S; Christidi, I A; Christov, A; Chromek-Burckhart, D; Chu, M L; Chudoba, J; Ciapetti, G; Ciftci, A K; Ciftci, R; Cinca, D; Cindro, V; Ciobotaru, M D; Ciocca, C; Ciocio, A; Cirilli, M; Citterio, M; Clark, A; Cleland, W; Clemens, J C; Clement, B; Clement, C; Coadou, Y; Cobal, M; Coccaro, A; Cochran, J; Coelli, S; Coggeshall, J; Cogneras, E; Cojocaru, C D; Colas, J; Cole, B; Colijn, A P; Collard, C; Collins, N J; Collins-Tooth, C; Collot, J; Colon, G; Conde Muiño, P; Coniavitis, E; Consonni, M; Constantinescu, S; Conta, C; Conventi, F; Cook, J; Cooke, M; Cooper, B D; Cooper-Sarkar, A M; Cooper-Smith, N J; Copic, K; Cornelissen, T; Corradi, M; Corriveau, F; Corso-Radu, A; Cortes-Gonzalez, A; Cortiana, G; Costa, G; Costa, M J; Costanzo, D; Costin, T; Côté, D; Coura Torres, R; Courneyea, L; Cowan, G; Cowden, C; Cox, B E; Cranmer, K; Cranshaw, J; Cristinziani, M; Crosetti, G; Crupi, R; Crépé-Renaudin, S; Cuenca Almenar, C; Cuhadar Donszelmann, T; Curatolo, M; Curtis, C J; Cwetanski, P; Czyczula, Z; D'Auria, S; D'Onofrio, M; D'Orazio, A; Da Silva, P V M; Da Via, C; Dabrowski, W; Dai, T; Dallapiccola, C; Dallison, S J; Daly, C H; Dam, M; Danielsson, H O; Dannheim, D; Dao, V; Darbo, G; Darlea, G L; Davey, W; Davidek, T; Davidson, N; Davidson, R; Davies, M; Davison, A R; Dawson, I; Dawson, J W; Daya, R K; De, K; de Asmundis, R; De Castro, S; De Castro Faria Salgado, P E; De Cecco, S; de Graat, J; De Groot, N; de Jong, P; De La Cruz-Burelo, E; De La Taille, C; De Mora, L; De Oliveira Branco, M; De Pedis, D; De Salvo, A; De Sanctis, U; De Santo, A; De Vivie De Regie, J B; De Zorzi, G; Dean, S; Deberg, H; Dedes, G; Dedovich, D V; Defay, P O; Degenhardt, J; Dehchar, M; Del Papa, C; Del Peso, J; Del Prete, T; Dell'Acqua, A; Dell'Asta, L; Della Pietra, M; della Volpe, D; Delmastro, M; Delruelle, N; Delsart, P A; Deluca, C; Demers, S; Demichev, M; Demirkoz, B; Deng, J; Deng, W; Denisov, S P; Dennis, C; Derkaoui, J E; Derue, F; Dervan, P; Desch, K; Deviveiros, P O; Dewhurst, A; DeWilde, B; Dhaliwal, S; Dhullipudi, R; Di Ciaccio, A; Di Ciaccio, L; Di Domenico, A; Di Girolamo, A; Di Girolamo, B; Di Luise, S; Di Mattia, A; Di Nardo, R; Di Simone, A; Di Sipio, R; Diaz, M A; Diblen, F; Diehl, E B; Dietrich, J; Dietzsch, T A; Diglio, S; Dindar Yagci, K; Dingfelder, D J; Dionisi, C; Dita, P; Dita, S; Dittus, F; Djama, F; Djilkibaev, R; Djobava, T; do Vale, M A B; Do Valle Wemans, A; Doan, T K O; Dobbs, M; Dobos, D; Dobson, E; Dobson, M; Dodd, J; Doherty, T; Doi, Y; Dolejsi, J; Dolenc, I; Dolezal, Z; Dolgoshein, B A; Dohmae, T; Donega, M; Donini, J; Dopke, J; Doria, A; Dos Anjos, A; Dotti, A; Dova, M T; Doxiadis, A; Doyle, A T; Drasal, Z; Driouichi, C; Dris, M; Dubbert, J; Duchovni, E; Duckeck, G; Dudarev, A; Dudziak, F; Dührssen , M; Duflot, L; Dufour, M A; Dunford, M; Duperrin, A; Duran Yildiz, H; Dushkin, A; Duxfield, R; Dwuznik, M; Düren, M; Ebenstein, W L; Ebke, J; Eckert, S; Eckweiler, S; Edmonds, K; Edwards, C A; Eerola, P; Egorov, K; Ehrenfeld, W; Ehrich, T; Eifert, T; Eigen, G; Einsweiler, K; Eisenhandler, E; Ekelof, T; El Kacimi, M; Ellert, M; Elles, S; Ellinghaus, F; Ellis, K; Ellis, N; Elmsheuser, J; Elsing, M; Ely, R; Emeliyanov, D; Engelmann, R; Engl, A; Epp, B; Eppig, A; Epshteyn, V S; Ereditato, A; Eriksson, D; Ermoline, I; Ernst, J; Ernst, M; Ernwein, J; Errede, D; Errede, S; Ertel, E; Escalier, M; Escobar, C; Espinal Curull, X; Esposito, B; Etienne, F; Etienvre, A I; Etzion, E; Evans, H; Fabbri, L; Fabre, C; Facius, K; Fakhrutdinov, R M; Falciano, S; Falou, A C; Fang, Y; Fanti, M; Farbin, A; Farilla, A; Farley, J; Farooque, T; Farrington, S M; Farthouat, P; Fassi, F; Fassnacht, P; Fassouliotis, D; Fatholahzadeh, B; Fayard, L; Fayette, F; Febbraro, R; Federic, P; Fedin, O L; Fedorko, I; Fedorko, W; Feligioni, L; Felzmann, C U; Feng, C; Feng, E J; Fenyuk, A B; Ferencei, J; Ferland, J; Fernandes, B; Fernando, W; Ferrag, S; Ferrando, J; Ferrari, A; Ferrari, P; Ferrari, R; Ferrer, A; Ferrer, M L; Ferrere, D; Ferretti, C; Fiascaris, M; Fiedler, F; Filipcic, A; Filippas, A; Filthaut, F; Fincke-Keeler, M; Fiolhais, M C N; Fiorini, L; Firan, A; Fischer, G; Fisher, M J; Flechl, M; Fleck, I; Fleckner, J; Fleischmann, P; Fleischmann, S; Flick, T; Flores Castillo, L R; Flowerdew, M J; Föhlisch, F; Fokitis, M; Fonseca Martin, T; Forbush, D A; Formica, A; Forti, A; Fortin, D; Foster, J M; Fournier, D; Foussat, A; Fowler, A J; Fowler, K; Fox, H; Francavilla, P; Franchino, S; Francis, D; Franklin, M; Franz, S; Fraternali, M; Fratina, S; Freestone, J; French, S T; Froeschl, R; Froidevaux, D; Frost, J A; Fukunaga, C; Fullana Torregrosa, E; Fuster, J; Gabaldon, C; Gabizon, O; Gadfort, T; Gadomski, S; Gagliardi, G; Gagnon, P; Galea, C; Gallas, E J; Gallas, M V; Gallo, V; Gallop, B J; Gallus, P; Galyaev, E; Gan, K K; Gao, Y S; Gaponenko, A; Garcia-Sciveres, M; García, C; García Navarro, J E; Gardner, R W; Garelli, N; Garitaonandia, H; Garonne, V; Gatti, C; Gaudio, G; Gaumer, O; Gauzzi, P; Gavrilenko, I L; Gay, C; Gaycken, G; Gayde, J C; Gazis, E N; Ge, P; Gee, C N P; Geich-Gimbel, Ch; Gellerstedt, K; Gemme, C; Genest, M H; Gentile, S; Georgatos, F; George, S; Gerlach, P; Gershon, A; Geweniger, C; Ghazlane, H; Ghez, P; Ghodbane, N; Giacobbe, B; Giagu, S; Giakoumopoulou, V; Giangiobbe, V; Gianotti, F; Gibbard, B; Gibson, A; Gibson, S M; Gilbert, L M; Gilchriese, M; Gilewsky, V; Gillman, A R; Gingrich, D M; Ginzburg, J; Giokaris, N; Giordani, M P; Giordano, R; Giovannini, P; Giraud, P F; Girtler, P; Giugni, D; Giusti, P; Gjelsten, B K; Gladilin, L K; Glasman, C; Glazov, A; Glitza, K W; Glonti, G L; Godfrey, J; Godlewski, J; Goebel, M; Göpfert, T; Goeringer, C; Gössling, C; Göttfert, T; Goggi, V; Goldfarb, S; Goldin, D; Golling, T; Gollub, N P; Gomes, A; Gomez Fajardo, L S; Gonçalo, R; Gonella, L; Gong, C; González de la Hoz, S; Gonzalez Silva, M L; Gonzalez-Sevilla, S; Goodson, J J; Goossens, L; Gorbounov, P A; Gordon, H A; Gorelov, I; Gorfine, G; Gorini, B; Gorini, E; Gorisek, A; Gornicki, E; Goryachev, V N; Gosdzik, B; Gosselink, M; Gostkin, M I; Gough Eschrich, I; Gouighri, M; Goujdami, D; Goulette, M P; Goussiou, A G; Goy, C; Grabowska-Bold, I; Grafström, P; Grahn, K J; Granado Cardoso, L; Grancagnolo, F; Grancagnolo, S; Grassi, V; Gratchev, V; Grau, N; Gray, H M; Gray, J A; Graziani, E; Green, B; Greenshaw, T; Greenwood, Z D; Gregor, I M; Grenier, P; Griesmayer, E; Griffiths, J; Grigalashvili, N; Grillo, A A; Grimm, K; Grinstein, S; Grishkevich, Y V; Groer, L S; Grognuz, J; Groh, M; Groll, M; Gross, E; Grosse-Knetter, J; Groth-Jensen, J; Grybel, K; Guarino, V J; Guicheney, C; Guida, A; Guillemin, T; Guler, H; Gunther, J; Guo, B; Gupta, A; Gusakov, Y; Gutierrez, A; Gutierrez, P; Guttman, N; Gutzwiller, O; Guyot, C; Gwenlan, C; Gwilliam, C B; Haas, A; Haas, S; Haber, C; Hackenburg, R; Hadavand, H K; Hadley, D R; Haefner, P; Härtel, R; Hajduk, Z; Hakobyan, H; Haller, J; Hamacher, K; Hamilton, A; Hamilton, S; Han, H; Han, L; Hanagaki, K; Hance, M; Handel, C; Hanke, P; Hansen, J R; Hansen, J B; Hansen, J D; Hansen, P H; Hansl-Kozanecka, T; Hansson, P; Hara, K; Hare, G A; Harenberg, T; Harrington, R D; Harris, O M; Harrison, K; Hartert, J; Hartjes, F; Haruyama, T; Harvey, A; Hasegawa, S; Hasegawa, Y; Hashemi, K; Hassani, S; Hatch, M; Haug, F; Haug, S; Hauschild, M; Hauser, R; Havranek, M; Hawkes, C M; Hawkings, R J; Hawkins, D; Hayakawa, T; Hayward, H S; Haywood, S J; He, M; Head, S J; Hedberg, V; Heelan, L; Heim, S; Heinemann, B; Heisterkamp, S; Helary, L; Heller, M; Hellman, S; Helsens, C; Hemperek, T; Henderson, R C W; Henke, M; Henrichs, A; Henriques Correia, A M; Henrot-Versille, S; Hensel, C; Henss, T; Hernández Jiménez, Y; Hershenhorn, A D; Herten, G; Hertenberger, R; Hervas, L; Hessey, N P; Hidvegi, A; Higón-Rodriguez, E; Hill, D; Hill, J C; Hiller, K H; Hillert, S; Hillier, S J; Hinchliffe, I; Hines, E; Hirose, M; Hirsch, F; Hirschbuehl, D; Hobbs, J; Hod, N; Hodgkinson, M C; Hodgson, P; Hoecker, A; Hoeferkamp, M R; Hoffman, J; Hoffmann, D; Hohlfeld, M; Holmgren, S O; Holy, T; Holzbauer, J L; Homma, Y; Homola, P; Horazdovsky, T; Hori, T; Horn, C; Horner, S; Horvat, S; Hostachy, J Y; Hou, S; Houlden, M A; Hoummada, A; Howe, T; Hrivnac, J; Hryn'ova, T; Hsu, P J; Hsu, S C; Huang, G S; Hubacek, Z; Hubaut, F; Huegging, F; Hughes, E W; Hughes, G; Hughes-Jones, R E; Hurst, P; Hurwitz, M; Husemann, U; Huseynov, N; Huston, J; Huth, J; Iacobucci, G; Iakovidis, G; Ibragimov, I; Iconomidou-Fayard, L; Idarraga, J; Iengo, P; Igonkina, O; Ikegami, Y; Ikeno, M; Ilchenko, Y; Iliadis, D; Ilyushenka, Y; Imori, M; Ince, T; Ioannou, P; Iodice, M; Irles Quiles, A; Ishikawa, A; Ishino, M; Ishmukhametov, R; Isobe, T; Issakov, V; Issever, C; Istin, S; Itoh, Y; Ivashin, A V; Iwasaki, H; Izen, J M; Izzo, V; Jackson, B; Jackson, J N; Jackson, P; Jaekel, M; Jahoda, M; Jain, V; Jakobs, K; Jakobsen, S; Jakubek, J; Jana, D; Jansen, E; Jantsch, A; Janus, M; Jared, R C; Jarlskog, G; Jarron, P; Jeanty, L; Jen-La Plante, I; Jenni, P; Jez, P; Jézéquel, S; Ji, W; Jia, J; Jiang, Y; Jimenez-Belenguer, M; Jin, G; Jin, S; Jinnouchi, O; Joffe, D; Johansen, M; Johansson, K E; Johansson, P; Johnert, S; Johns, K A; Jon-And, K; Jones, G; Jones, R W L; Jones, T W; Jones, T J; Jonsson, O; Joos, D; Joram, C; Jorge, P M; Juranek, V; Jussel, P; Kabachenko, V V; Kabana, S; Kaci, M; Kaczmarska, A; Kado, M; Kagan, H; Kagan, M; Kaiser, S; Kajomovitz, E; Kalinin, S; Kalinovskaya, L V; Kalinowski, A; Kama, S; Kanaya, N; Kaneda, M; Kantserov, V A; Kanzaki, J; Kaplan, B; Kapliy, A; Kaplon, J; Karagounis, M; Karagoz Unel, M; Kartvelishvili, V; Karyukhin, A N; Kashif, L; Kasmi, A; Kass, R D; Kastanas, A; Kastoryano, M; Kataoka, M; Kataoka, Y; Katsoufis, E; Katzy, J; Kaushik, V; Kawagoe, K; Kawamoto, T; Kawamura, G; Kayl, M S; Kayumov, F; Kazanin, V A; Kazarinov, M Y; Kazi, S I; Keates, J R; Keeler, R; Keener, P T; Kehoe, R; Keil, M; Kekelidze, G D; Kelly, M; Kennedy, J; Kenyon, M; Kepka, O; Kerschen, N; Kersevan, B P; Kersten, S; Kessoku, K; Khakzad, M; Khalil-zada, F; Khandanyan, H; Khanov, A; Kharchenko, D; Khodinov, A; Kholodenko, A G; Khomich, A; Khoriauli, G; Khovanskiy, N; Khovanskiy, V; Khramov, E; Khubua, J; Kilvington, G; Kim, H; Kim, M S; Kim, P C; Kim, S H; Kind, O; Kind, P; King, B T; Kirk, J; Kirsch, G P; Kirsch, L E; Kiryunin, A E; Kisielewska, D; Kittelmann, T; Kiyamura, H; Kladiva, E; Klein, M; Klein, U; Kleinknecht, K; Klemetti, M; Klier, A; Klimentov, A; Klingenberg, R; Klinkby, E B; Klioutchnikova, T; Klok, P F; Klous, S; Kluge, E E; Kluge, T; Kluit, P; Klute, M; Kluth, S; Knecht, N S; Kneringer, E; Ko, B R; Kobayashi, T; Kobel, M; Koblitz, B; Kocian, M; Kocnar, A; Kodys, P; Köneke, K; König, A C; Köpke, L; Koetsveld, F; Koevesarki, P; Koffas, T; Koffeman, E; Kohn, F; Kohout, Z; Kohriki, T; Kokott, T; Kolanoski, H; Kolesnikov, V; Koletsou, I; Koll, J; Kollar, D; Kolos, S; Kolya, S D; Komar, A A; Komaragiri, J R; Kondo, T; Kono, T; Kononov, A I; Konoplich, R; Konovalov, S P; Konstantinidis, N; Koperny, S; Korcyl, K; Kordas, K; Koreshev, V; Korn, A; Korolkov, I; Korolkova, E V; Korotkov, V A; Kortner, O; Kostka, P; Kostyukhin, V V; Kotamäki, M J; Kotov, S; Kotov, V M; Kotov, K Y; Koupilova, Z; Kourkoumelis, C; Koutsman, A; Kowalewski, R; Kowalski, H; Kowalski, T Z; Kozanecki, W; Kozhin, A S; Kral, V; Kramarenko, V A; Kramberger, G; Krasny, M W; Krasznahorkay, A; Kreisel, A; Krejci, F; Krepouri, A; Kretzschmar, J; Krieger, P; Krobath, G; Kroeninger, K; Kroha, H; Kroll, J; Kroseberg, J; Krstic, J; Kruchonak, U; Krüger, H; Krumshteyn, Z V; Kubota, T; Kuehn, S; Kugel, A; Kuhl, T; Kuhn, D; Kukhtin, V; Kulchitsky, Y; Kuleshov, S; Kummer, C; Kuna, M; Kunkle, J; Kupco, A; Kurashige, H; Kurata, M; Kurchaninov, L L; Kurochkin, Y A; Kus, V; Kuznetsova, E; Kvasnicka, O; Kwee, R; La Rotonda, L; Labarga, L; Labbe, J; Lacasta, C; Lacava, F; Lacker, H; Lacour, D; Lacuesta, V R; Ladygin, E; Lafaye, R; Laforge, B; Lagouri, T; Lai, S; Lamanna, M; Lampen, C L; Lampl, W; Lancon, E; Landgraf, U; Landon, M P J; Lane, J L; Lankford, A J; Lanni, F; Lantzsch, K; Lanza, A; Laplace, S; Lapoire, C; Laporte, J F; Lari, T; Larionov, A V; Larner, A; Lasseur, C; Lassnig, M; Laurelli, P; Lavrijsen, W; Laycock, P; Lazarev, A B; Lazzaro, A; Le Dortz, O; Le Guirriec, E; Le Maner, C; Le Menedeu, E; Le Vine, M; Leahu, M; Lebedev, A; Lebel, C; LeCompte, T; Ledroit-Guillon, F; Lee, H; Lee, J S H; Lee, S C; Lefebvre, M; Legendre, M; LeGeyt, B C; Legger, F; Leggett, C; Lehmacher, M; Lehmann Miotto, G; Lei, X; Leitner, R; Lelas, D; Lellouch, D; Lellouch, J; Leltchouk, M; Lendermann, V; Leney, K J C; Lenz, T; Lenzen, G; Lenzi, B; Leonhardt, K; Leroy, C; Lessard, J R; Lester, C G; Leung Fook Cheong, A; Levêque, J; Levin, D; Levinson, L J; Levitski, M S; Levonian, S; Lewandowska, M; Leyton, M; Li, H; Li, J; Li, S; Li, X; Liang, Z; Liang, Z; Liberti, B; Lichard, P; Lichtnecker, M; Lie, K; Liebig, W; Liko, D; Lilley, J N; Lim, H; Limosani, A; Limper, M; Lin, S C; Lindsay, S W; Linhart, V; Linnemann, J T; Liolios, A; Lipeles, E; Lipinsky, L; Lipniacka, A; Liss, T M; Lissauer, D; Lister, A; Litke, A M; Liu, C; Liu, D; Liu, H; Liu, J B; Liu, M; Liu, S; Liu, T; Liu, Y; Livan, M; Lleres, A; Lloyd, S L; Lobodzinska, E; Loch, P; Lockman, W S; Lockwitz, S; Loddenkoetter, T; Loebinger, F K; Loginov, A; Loh, C W; Lohse, T; Lohwasser, K; Lokajicek, M; Loken, J; Lopes, L; Lopez Mateos, D; Losada, M; Loscutoff, P; Losty, M J; Lou, X; Lounis, A; Loureiro, K F; Lovas, L; Love, J; Love, P; Lowe, A J; Lu, F; Lu, J; Lubatti, H J; Luci, C; Lucotte, A; Ludwig, A; Ludwig, D; Ludwig, I; Ludwig, J; Luehring, F; Luisa, L; Lumb, D; Luminari, L; Lund, E; Lund-Jensen, B; Lundberg, B; Lundberg, J; Lundquist, J; Lutz, G; Lynn, D; Lys, J; Lytken, E; Ma, H; Ma, L L; Macana Goia, J A; Maccarrone, G; Macchiolo, A; Macek, B; Machado Miguens, J; Mackeprang, R; Madaras, R J; Mader, W F; Maenner, R; Maeno, T; Mättig, P; Mättig, S; Magalhaes Martins, P J; Magradze, E; Magrath, C A; Mahalalel, Y; Mahboubi, K; Mahmood, A; Mahout, G; Maiani, C; Maidantchik, C; Maio, A; Majewski, S; Makida, Y; Makouski, M; Makovec, N; Malecki, Pa; Malecki, P; Maleev, V P; Malek, F; Mallik, U; Malon, D; Maltezos, S; Malyshev, V; Malyukov, S; Mambelli, M; Mameghani, R; Mamuzic, J; Manabe, A; Mandelli, L; Mandic, I; Mandrysch, R; Maneira, J; Mangeard, P S; Manjavidze, I D; Manning, P M; Manousakis-Katsikakis, A; Mansoulie, B; Mapelli, A; Mapelli, L; March, L; Marchand, J F; Marchese, F; Marchiori, G; Marcisovsky, M; Marino, C P; Marques, C N; Marroquim, F; Marshall, R; Marshall, Z; Martens, F K; Marti i Garcia, S; Martin, A J; Martin, A J; Martin, B; Martin, B; Martin, F F; Martin, J P; Martin, T A; Martin dit Latour, B; Martinez, M; Martinez Outschoorn, V; Martini, A; Martyniuk, A C; Maruyama, T; Marzano, F; Marzin, A; Masetti, L; Mashimo, T; Mashinistov, R; Masik, J; Maslennikov, A L; Massaro, G; Massol, N; Mastroberardino, A; Masubuchi, T; Mathes, M; Matricon, P; Matsunaga, H; Matsushita, T; Mattravers, C; Maxfield, S J; May, E N; Mayne, A; Mazini, R; Mazur, M; Mazzanti, M; Mazzanti, P; Mc Donald, J; Mc Kee, S P; McCarn, A; McCarthy, R L; McCubbin, N A; McFarlane, K W; McGlone, H; Mchedlidze, G; McLaren, R A; McMahon, S J; McMahon, T R; McPherson, R A; Meade, A; Mechnich, J; Mechtel, M; Medinnis, M; Meera-Lebbai, R; Meguro, T M; Mehdiyev, R; Mehlhase, S; Mehta, A; Meier, K; Meirose, B; Melachrinos, C; Melamed-Katz, A; Mellado Garcia, B R; Meng, Z; Menke, S; Meoni, E; Merkl, D; Mermod, P; Merola, L; Meroni, C; Merritt, F S; Messina, A M; Messmer, I; Metcalfe, J; Mete, A S; Meyer, J P; Meyer, J; Meyer, J; Meyer, T C; Meyer, W T; Miao, J; Michal, S; Micu, L; Middleton, R P; Migas, S; Mijovic, L; Mikenberg, G; Mikuz, M; Miller, D W; Mills, W J; Mills, C M; Milov, A; Milstead, D A; Minaenko, A A; Miñano, M; Minashvili, I A; Mincer, A I; Mindur, B; Mineev, M; Ming, Y; Mir, L M; Mirabelli, G; Misawa, S; Miscetti, S; Misiejuk, A; Mitrevski, J; Mitsou, V A; Miyagawa, P S; Mjörnmark, J U; Mladenov, D; Moa, T; Moed, S; Moeller, V; Mönig, K; Möser, N; Mohn, B; Mohr, W; Mohrdieck-Möck, S; Moles-Valls, R; Molina-Perez, J; Moloney, G; Monk, J; Monnier, E; Montesano, S; Monticelli, F; Moore, R W; Mora Herrera, C; Moraes, A; Morais, A; Morel, J; Morello, G; Moreno, D; Moreno Llácer, M; Morettini, P; Morii, M; Morley, A K; Mornacchi, G; Morozov, S V; Morris, J D; Moser, H G; Mosidze, M; Moss, J; Mount, R; Mountricha, E; Mouraviev, S V; Moyse, E J W; Mudrinic, M; Mueller, F; Mueller, J; Mueller, K; Müller, T A; Muenstermann, D; Muir, A; Munwes, Y; Murillo Garcia, R; Murray, W J; Mussche, I; Musto, E; Myagkov, A G; Myska, M; Nadal, J; Nagai, K; Nagano, K; Nagasaka, Y; Nairz, A M; Nakamura, K; Nakano, I; Nakatsuka, H; Nanava, G; Napier, A; Nash, M; Nation, N R; Nattermann, T; Naumann, T; Navarro, G; Nderitu, S K; Neal, H A; Nebot, E; Nechaeva, P; Negri, A; Negri, G; Nelson, A; Nelson, T K; Nemecek, S; Nemethy, P; Nepomuceno, A A; Nessi, M; Neubauer, M S; Neusiedl, A; Neves, R N; Nevski, P; Newcomer, F M; Nickerson, R B; Nicolaidou, R; Nicolas, L; Nicoletti, G; Niedercorn, F; Nielsen, J; Nikiforov, A; Nikolaev, K; Nikolic-Audit, I; Nikolopoulos, K; Nilsen, H; Nilsson, P; Nisati, A; Nishiyama, T; Nisius, R; Nodulman, L; Nomachi, M; Nomidis, I; Nordberg, M; Nordkvist, B; Notz, D; Novakova, J; Nozaki, M; Nozicka, M; Nugent, I M; Nuncio-Quiroz, A -E; Nunes Hanninger, G; Nunnemann, T; Nurse, E; O'Neil, D C; O'Shea, V; Oakham, F G; Oberlack, H; Ochi, A; Oda, S; Odaka, S; Odier, J; Odino, G A; Ogren, H; Oh, A; Oh, S H; Ohm, C C; Ohshima, T; Ohshita, H; Ohsugi, T; Okada, S; Okawa, H; Okumura, Y; Olcese, M; Olchevski, A G; Oliveira, M; Oliveira Damazio, D; Oliver, J; Oliver Garcia, E; Olivito, D; Olszewski, A; Olszowska, J; Omachi, C; Onofre, A; Onyisi, P U E; Oram, C J; Ordonez, G; Oreglia, M J; Oren, Y; Orestano, D; Orlov, I; Oropeza Barrera, C; Orr, R S; Ortega, E O; Osculati, B; Ospanov, R; Osuna, C; Otec, R; Ottersbach, J P; Ould-Saada, F; Ouraou, A; Ouyang, Q; Owen, M; Owen, S; Oyarzun, A; Ozcan, V E; Ozone, K; Ozturk, N; Pacheco Pages, A; Padhi, S; Padilla Aranda, C; Paganis, E; Pahl, C; Paige, F; Pajchel, K; Palestini, S; Pallin, D; Palma, A; Palmer, J D; Pan, Y B; Panagiotopoulou, E; Panes, B; Panikashvili, N; Panitkin, S; Pantea, D; Panuskova, M; Paolone, V; Papadopoulou, Th D; Park, S J; Park, W; Parker, M A; Parker, S I; Parodi, F; Parsons, J A; Parzefall, U; Pasqualucci, E; Passardi, G; Passeri, A; Pastore, F; Pastore, Fr; Pásztor, G; Pataraia, S; Pater, J R; Patricelli, S; Patwa, A; Pauly, T; Peak, L S; Pecsy, M; Pedraza Morales, M I; Peleganchuk, S V; Peng, H; Penson, A; Penwell, J; Perantoni, M; Perez, K; Perez Codina, E; Pérez García-Estañ, M T; Perez Reale, V; Perini, L; Pernegger, H; Perrino, R; Perrodo, P; Persembe, S; Perus, P; Peshekhonov, V D; Petersen, B A; Petersen, J; Petersen, T C; Petit, E; Petridou, C; Petrolo, E; Petrucci, F; Petschull, D; Petteni, M; Pezoa, R; Pfeifer, B; Phan, A; Phillips, A W; Piacquadio, G; Piccinini, M; Piegaia, R; Pilcher, J E; Pilkington, A D; Pina, J; Pinamonti, M; Pinfold, J L; Ping, J; Pinto, B; Pizio, C; Placakyte, R; Plamondon, M; Plano, W G; Pleier, M A; Poblaguev, A; Poddar, S; Podlyski, F; Poffenberger, P; Poggioli, L; Pohl, M; Polci, F; Polesello, G; Policicchio, A; Polini, A; Poll, J; Polychronakos, V; Pomarede, D M; Pomeroy, D; Pommès, K; Pontecorvo, L; Pope, B G; Popovic, D S; Poppleton, A; Popule, J; Portell Bueso, X; Porter, R; Pospelov, G E; Pospichal, P; Pospisil, S; Potekhin, M; Potrap, I N; Potter, C J; Potter, C T; Potter, K P; Poulard, G; Poveda, J; Prabhu, R; Pralavorio, P; Prasad, S; Pravahan, R; Preda, T; Pretzl, K; Pribyl, L; Price, D; Price, L E; Prichard, P M; Prieur, D; Primavera, M; Prokofiev, K; Prokoshin, F; Protopopescu, S; Proudfoot, J; Prudent, X; Przysiezniak, H; Psoroulas, S; Ptacek, E; Puigdengoles, C; Purdham, J; Purohit, M; Puzo, P; Pylypchenko, Y; Qi, M; Qian, J; Qian, W; Qian, Z; Qin, Z; Qing, D; Quadt, A; Quarrie, D R; Quayle, W B; Quinonez, F; Raas, M; Radeka, V; Radescu, V; Radics, B; Rador, T; Ragusa, F; Rahal, G; Rahimi, A M; Rahm, D; Rajagopalan, S; Rammes, M; Ratoff, P N; Rauscher, F; Rauter, E; Raymond, M; Read, A L; Rebuzzi, D M; Redelbach, A; Redlinger, G; Reece, R; Reeves, K; Reinherz-Aronis, E; Reinsch, A; Reisinger, I; Reljic, D; Rembser, C; Ren, Z L; Renkel, P; Rescia, S; Rescigno, M; Resconi, S; Resende, B; Reznicek, P; Rezvani, R; Richards, A; Richards, R A; Richter, R; Richter-Was, E; Ridel, M; Rieke, S; Rijpstra, M; Rijssenbeek, M; Rimoldi, A; Rinaldi, L; Rios, R R; Riu, I; Rivoltella, G; Rizatdinova, F; Rizvi, E R; Roa Romero, D A; Robertson, S H; Robichaud-Veronneau, A; Robinson, D; Robinson, J; Robinson, M; Robson, A; Rocha de Lima, J G; Roda, C; Roda Dos Santos, D; Rodriguez, D; Rodriguez Garcia, Y; Roe, S; Røhne, O; Rojo, V; Rolli, S; Romaniouk, A; Romanov, V M; Romeo, G; Romero Maltrana, D; Roos, L; Ros, E; Rosati, S; Rosenbaum, G A; Rosenberg, E I; Rosselet, L; Rossetti, V; Rossi, L P; Rotaru, M; Rothberg, J; Rottländer, I; Rousseau, D; Royon, C R; Rozanov, A; Rozen, Y; Ruan, X; Ruckert, B; Ruckstuhl, N; Rud, V I; Rudolph, G; Rühr, F; Ruggieri, F; Ruiz-Martinez, A; Rumyantsev, L; Rusakovich, N A; Rutherfoord, J P; Ruwiedel, C; Ruzicka, P; Ryabov, Y F; Ryadovikov, V; Ryan, P; Rybkin, G; Rzaeva, S; Saavedra, A F; Sadrozinski, H F W; Sadykov, R; Sakamoto, H; Salamanna, G; Salamon, A; Saleem, M; Salihagic, D; Salnikov, A; Salt, J; Salvachua Ferrando, B M; Salvatore, D; Salvatore, F; Salvucci, A; Salzburger, A; Sampsonidis, D; Samset, B H; Sanchis Lozano, M A; Sandaker, H; Sander, H G; Sanders, M P; Sandhoff, M; Sandstroem, R; Sandvoss, S; Sankey, D P C; Sanny, B; Sansoni, A; Santamarina Rios, C; Santi, L; Santoni, C; Santonico, R; Santos, J; Saraiva, J G; Sarangi, T; Sarkisyan-Grinbaum, E; Sarri, F; Sasaki, O; Sasaki, T; Sasao, N; Satsounkevitch, I; Sauvage, G; Savard, P; Savine, A Y; Savinov, V; Sawyer, L; Saxon, D H; Says, L P; Sbarra, C; Sbrizzi, A; Scannicchio, D A; Schaarschmidt, J; Schacht, P; Schäfer, U; Schaetzel, S; Schaffer, A C; Schaile, D; Schamberger, R D; Schamov, A G; Schegelsky, V A; Scheirich, D; Schernau, M; Scherzer, M I; Schiavi, C; Schieck, J; Schioppa, M; Schlenker, S; Schlereth, J L; Schmid, P; Schmieden, K; Schmitt, C; Schmitz, M; Schott, M; Schouten, D; Schovancova, J; Schram, M; Schreiner, A; Schroeder, C; Schroer, N; Schroers, M; Schuler, G; Schultes, J; Schultz-Coulon, H C; Schumacher, J W; Schumacher, M; Schumm, B A; Schune, Ph; Schwanenberger, C; Schwartzman, A; Schwemling, Ph; Schwienhorst, R; Schwierz, R; Schwindling, J; Scott, W G; Searcy, J; Sedykh, E; Segura, E; Seidel, S C; Seiden, A; Seifert, F; Seixas, J M; Sekhniaidze, G; Seliverstov, D M; Sellden, B; Seman, M; Semprini-Cesari, N; Serfon, C; Serin, L; Seuster, R; Severini, H; Sevior, M E; Sfyrla, A; Shabalina, E; Shamim, M; Shan, L Y; Shank, J T; Shao, Q T; Shapiro, M; Shatalov, P B; Shaver, L; Shaw, K; Sherman, D; Sherwood, P; Shibata, A; Shimojima, M; Shin, T; Shmeleva, A; Shochet, M J; Shupe, M A; Sicho, P; Sidoti, A; Siebel, A; Siegert, F; Siegrist, J; Sijacki, Dj; Silbert, O; Silva, J; Silver, Y; Silverstein, D; Silverstein, S B; Simak, V; Simic, Lj; Simion, S; Simmons, B; Simonyan, M; Sinervo, P; Sinev, N B; Sipica, V; Siragusa, G; Sisakyan, A N; Sivoklokov, S Yu; Sjoelin, J; Sjursen, T B; Skubic, P; Skvorodnev, N; Slater, M; Slavicek, T; Sliwa, K; Sloper, J; Sluka, T; Smakhtin, V; Smirnov, S Yu; Smirnov, Y; Smirnova, L N; Smirnova, O; Smith, B C; Smith, D; Smith, K M; Smizanska, M; Smolek, K; Snesarev, A A; Snow, S W; Snow, J; Snuverink, J; Snyder, S; Soares, M; Sobie, R; Sodomka, J; Soffer, A; Solans, C A; Solar, M; Solc, J; Solfaroli Camillocci, E; Solodkov, A A; Solovyanov, O V; Soluk, R; Sondericker, J; Sopko, V; Sopko, B; Sosebee, M; Sosnovtsev, V V; Sospedra Suay, L; Soukharev, A; Spagnolo, S; Spanó, F; Speckmayer, P; Spencer, E; Spighi, R; Spigo, G; Spila, F; Spiwoks, R; Spousta, M; Spreitzer, T; Spurlock, B; St Denis, R D; Stahl, T; Stahlman, J; Stamen, R; Stancu, S N; Stanecka, E; Stanek, R W; Stanescu, C; Stapnes, S; Starchenko, E A; Stark, J; Staroba, P; Starovoitov, P; Stastny, J; Staude, A; Stavina, P; Stavropoulos, G; Steele, G; Steinbach, P; Steinberg, P; Stekl, I; Stelzer, B; Stelzer, H J; Stelzer-Chilton, O; Stenzel, H; Stevenson, K; Stewart, G; Stockton, M C; Stoerig, K; Stoicea, G; Stonjek, S; Strachota, P; Stradling, A; Straessner, A; Strandberg, J; Strandberg, S; Strandlie, A; Strauss, M; Strizenec, P; Ströhmer, R; Strom, D M; Strong, J A; Stroynowski, R; Strube, J; Stugu, B; Stumer, I; Soh, D A; Su, D; Suchkov, S I; Sugaya, Y; Sugimoto, T; Suhr, C; Suk, M; Sulin, V V; Sultansoy, S; Sumida, T; Sun, X; Sundermann, J E; Suruliz, K; Sushkov, S; Susinno, G; Sutton, M R; Suzuki, T; Suzuki, Y; Sviridov, Yu M; Sykora, I; Sykora, T; Szymocha, T; Sánchez, J; Ta, D; Tackmann, K; Taffard, A; Tafirout, R; Taga, A; Takahashi, Y; Takai, H; Takashima, R; Takeda, H; Takeshita, T; Talby, M; Talyshev, A; Tamsett, M C; Tanaka, J; Tanaka, R; Tanaka, S; Tanaka, S; Tappern, G P; Tapprogge, S; Tardif, D; Tarem, S; Tarrade, F; Tartarelli, G F; Tas, P; Tasevsky, M; Tassi, E; Tatarkhanov, M; Taylor, C; Taylor, F E; Taylor, G N; Taylor, R P; Taylor, W; Teixeira-Dias, P; Ten Kate, H; Teng, P K; Tennenbaum-Katan, Y D; Terada, S; Terashi, K; Terron, J; Terwort, M; Testa, M; Teuscher, R J; Tevlin, C M; Thadome, J; Thananuwong, R; Thioye, M; Thoma, S; Thomas, J P; Thomas, T L; Thompson, E N; Thompson, P D; Thompson, P D; Thompson, R J; Thompson, A S; Thomson, E; Thun, R P; Tic, T; Tikhomirov, V O; Tikhonov, Y A; Timmermans, C J W P; Tipton, P; Tique Aires Viegas, F J; Tisserant, S; Tobias, J; Toczek, B; Todorov, T; Todorova-Nova, S; Toggerson, B; Tojo, J; Tokár, S; Tokushuku, K; Tollefson, K; Tomasek, L; Tomasek, M; Tomasz, F; Tomoto, M; Tompkins, D; Tompkins, L; Toms, K; Tong, G; Tonoyan, A; Topfel, C; Topilin, N D; Torrence, E; Torró Pastor, E; Toth, J; Touchard, F; Tovey, D R; Tovey, S N; Trefzger, T; Tremblet, L; Tricoli, A; Trigger, I M; Trincaz-Duvoid, S; Trinh, T N; Tripiana, M F; Triplett, N; Trischuk, W; Trivedi, A; Trocmé, B; Troncon, C; Trzupek, A; Tsarouchas, C; Tseng, J C L; Tsiafis, I; Tsiakiris, M; Tsiareshka, P V; Tsionou, D; Tsipolitis, G; Tsiskaridze, V; Tskhadadze, E G; Tsukerman, I I; Tsulaia, V; Tsung, J W; Tsuno, S; Tsybychev, D; Turala, M; Turecek, D; Turk Cakir, I; Turlay, E; Tuts, P M; Twomey, M S; Tylmad, M; Tyndel, M; Tzanakos, G; Uchida, K; Ueda, I; Ugland, M; Uhlenbrock, M; Uhrmacher, M; Ukegawa, F; Unal, G; Underwood, D G; Undrus, A; Unel, G; Unno, Y; Urbaniec, D; Urkovsky, E; Urquijo, P; Urrejola, P; Usai, G; Uslenghi, M; Vacavant, L; Vacek, V; Vachon, B; Vahsen, S; Valenta, J; Valente, P; Valentinetti, S; Valkar, S; Valladolid Gallego, E; Vallecorsa, S; Valls Ferrer, J A; Van Berg, R; van der Graaf, H; van der Kraaij, E; van der Poel, E; Van Der Ster, D; van Eldik, N; van Gemmeren, P; van Kesteren, Z; van Vulpen, I; Vandelli, W; Vandoni, G; Vaniachine, A; Vankov, P; Vannucci, F; Varela Rodriguez, F; Vari, R; Varnes, E W; Varouchas, D; Vartapetian, A; Varvell, K E; Vasilyeva, L; Vassilakopoulos, V I; Vazeille, F; Vegni, G; Veillet, J J; Vellidis, C; Veloso, F; Veness, R; Veneziano, S; Ventura, A; Ventura, D; Venturi, M; Venturi, N; Vercesi, V; Verducci, M; Verkerke, W; Vermeulen, J C; Vetterli, M C; Vichou, I; Vickey, T; Viehhauser, G H A; Villa, M; Villani, E G; Villaplana Perez, M; Villate, J; Vilucchi, E; Vincter, M G; Vinek, E; Vinogradov, V B; Viret, S; Virzi, J; Vitale, A; Vitells, O V; Vivarelli, I; Vives Vaques, F; Vlachos, S; Vlasak, M; Vlasov, N; Vogel, A; Vokac, P; Volpi, M; Volpini, G; von der Schmitt, H; von Loeben, J; von Radziewski, H; von Toerne, E; Vorobel, V; Vorobiev, A P; Vorwerk, V; Vos, M; Voss, R; Voss, T T; Vossebeld, J H; Vranjes, N; Vranjes Milosavljevic, M; Vrba, V; Vreeswijk, M; Vu Anh, T; Vudragovic, D; Vuillermet, R; Vukotic, I; Wagner, P; Wahlen, H; Walbersloh, J; Walder, J; Walker, R; Walkowiak, W; Wall, R; Wang, C; Wang, H; Wang, J; Wang, J C; Wang, S M; Ward, C P; Warsinsky, M; Wastie, R; Watkins, P M; Watson, A T; Watson, M F; Watts, G; Watts, S; Waugh, A T; Waugh, B M; Webel, M; Weber, J; Weber, M D; Weber, M; Weber, M S; Weber, P; Weidberg, A R; Weingarten, J; Weiser, C; Wellenstein, H; Wells, P S; Wen, M; Wenaus, T; Wendler, S; Wengler, T; Wenig, S; Wermes, N; Werner, M; Werner, P; Werth, M; Werthenbach, U; Wessels, M; Whalen, K; Wheeler-Ellis, S J; Whitaker, S P; White, A; White, M J; White, S; Whiteson, D; Whittington, D; Wicek, F; Wicke, D; Wickens, F J; Wiedenmann, W; Wielers, M; Wienemann, P; Wiglesworth, C; Wiik, L A M; Wildauer, A; Wildt, M A; Wilhelm, I; Wilkens, H G; Williams, E; Williams, H H; Willis, W; Willocq, S; Wilson, J A; Wilson, M G; Wilson, A; Wingerter-Seez, I; Winklmeier, F; Wittgen, M; Wolter, M W; Wolters, H; Wosiek, B K; Wotschack, J; Woudstra, M J; Wraight, K; Wright, C; Wright, D; Wrona, B; Wu, S L; Wu, X; Wulf, E; Xella, S; Xie, S; Xie, Y; Xu, D; Xu, N; Yamada, M; Yamamoto, A; Yamamoto, S; Yamamura, T; Yamanaka, K; Yamaoka, J; Yamazaki, T; Yamazaki, Y; Yan, Z; Yang, H; Yang, U K; Yang, Y; Yang, Z; Yao, W M; Yao, Y; Yasu, Y; Ye, J; Ye, S; Yilmaz, M; Yoosoofmiya, R; Yorita, K; Yoshida, R; Young, C; Youssef, S P; Yu, D; Yu, J; Yu, M; Yu, X; Yuan, J; Yuan, L; Yurkewicz, A; Zaidan, R; Zaitsev, A M; Zajacova, Z; Zambrano, V; Zanello, L; Zarzhitsky, P; Zaytsev, A; Zeitnitz, C; Zeller, M; Zema, P F; Zemla, A; Zendler, C; Zenin, O; Zenis, T; Zenonos, Z; Zenz, S; Zerwas, D; Zevi della Porta, G; Zhan, Z; Zhang, H; Zhang, J; Zhang, Q; Zhang, X; Zhao, L; Zhao, T; Zhao, Z; Zhemchugov, A; Zheng, S; Zhong, J; Zhou, B; Zhou, N; Zhou, Y; Zhu, C G; Zhu, H; Zhu, Y; Zhuang, X; Zhuravlov, V; Zimmermann, R; Zimmermann, S; Zimmermann, S; Ziolkowski, M; Zitoun, R; Zivkovic, L; Zmouchko, V V; Zobernig, G; Zoccoli, A; zur Nedden, M; Zutshi, V

    2010-01-01

    The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.7% in the endcaps. This leads to an estimated contribution to the constant term of 0.29% in the barrel and 0.53% in the endcaps. The same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61 +- 0.07 mm/microsecond at 88.5 K and 1 kV/mm.

  16. Liquid Argon Time Projection Chamber Research and Development in the United States

    CERN Document Server

    Bromberg, C; Junk, T; Katori, T; Lang, K; Marchionni, A; Mauger, C; Mufson, S; Pordes, S; Raaf, J; Rebel, B; Soderberg, M; Thorn, C; Urheim, J

    2013-01-01

    A workshop was held at Fermilab on March 20-21, 2013 to discuss the development of liquid argon time projection chambers (LArTPC) in the United States. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in plenary sessions organized into seven topical categories: $i)$ Argon Purity, $ii)$ Cryogenics, $iii)$ TPC and High Voltage, $iv)$ Electronics, Data Acquisition and Triggering, $v)$ Scintillation Light Detection, $vi)$ Calibration and Test Beams, and $vii)$ Software. This document summarizes the current efforts in each of these topical categories. It also highlights areas in LArTPC research and development that are common between neutrino experiments and dark matter experiments.

  17. Investigation of capacitively coupled argon plasma driven at various frequencies and validation of surface waves excitation

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Fattah, E., E-mail: essam29@hotmail.com [Physics Department, Faculty of Science, Zagazig University, Zagazig 44519 (Egypt); Physics Department, College of Science, Salman bin AbdulAziz University, Al-Kharj, P.O. 83, Al-Kharj 11942 (Saudi Arabia)

    2013-01-03

    The influence of excitation frequency (13.56–96 MHz) on the characteristics of capacitively coupled argon plasma is investigated by means of Langmuir probe and a high-voltage probe. Measurements are performed in argon pressure of 40 and 60 mTorr at a fixed discharge voltage V{sub pp}=200 V. The measured electron energy distribution function EEPFs are a bi-Maxwellian type irrespective of the driving frequency and gas pressure. The electron density and temperatures show peak over frequency range of 54–72 MHz, beyond which it decreases. The non-monotonic dependences of plasma parameters with driving frequency were interpreted in terms of excited surface wave excited at the powered electrode.

  18. Shock tube study of ionization rates of NaCl-contaminated argon

    Science.gov (United States)

    Schneider, K.-P.; Park, C.

    1975-01-01

    Electron density, electron temperature, and concentration of excited sodium atoms are measured in the weakly ionized regime behind a shock wave in impure argon in a shock tube using microwave techniques and spectrally resolved radiometry. Evidence is presented to show that an apparent increase in the rate of ionization is due to electron detachment of negative chlorine ions produced from sodium chloride vapor contained as an impurity. To be consistent with this chemical model, rate coefficients are found in the temperature range between 5500 and 8600 K for the dissociation of NaCl into an ion pair, dissociation of NaCl into a neutral pair, and electron detachment of a negative chlorine ion. Electron temperature is lower than heavy-particle temperature by roughly 1000 K. The electron-argon impact-ionization rate coefficient is a weak function of electron temperature in contradiction to expectation.

  19. Liquid Argon Time Projection Chamber research and development in the United States

    International Nuclear Information System (INIS)

    A workshop was held at Fermilab on March 20-21, 2013 to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in seven topical plenary sessions: i) Argon Purity, ii) Cryogenics, iii) TPC and High Voltage, iv) Electronics, Data Acquisition and Triggering, v) Scintillation Light Detection, vi) Calibration and Test Beams, and vii) Software. This document summarizes the current efforts in each of these areas. It also highlights areas in LArTPC research and development that are common between neutrino experiments and dark matter experiments

  20. ATLAS endcap liquid argon calorimeters. Description and construction of the cryostats

    International Nuclear Information System (INIS)

    All forward calorimeters of the ATLAS detector use the same detection technique, energy loss in passive plates, followed by ionisation and charge detection in liquid argon. They are therefore all grouped in the same vessel which must basically support and keep in place the heavy plates and the detection electrodes and maintain liquid argon at cold and stable temperature. Taking into account all the constraints as detailed below, and the overall detector size, 5 meter diameter by 3 meter length this was quite a challenge. The design, construction and tests of these two cryostats, up to their delivery at CERN, are described in this document. These two cryostats are a joint 'in kind' contribution to the Atlas experiment of LAL (Orsay), Max Planck Institute (Muenchen) and Wuppertal University (Wuppertal) and have been designed and built under the responsibility of LAL (Orsay) with contributions of the technical groups of the above institutions and of ATLAS-CERN. (authors)

  1. Hydrogen-bonded complexes of 2-aminopyrimidine-parabenzoquinone in an argon matrix

    Science.gov (United States)

    Plokhotnichenko, A. M.; Stepanian, S. G.; Karachevtsev, V. A.; Adamowicz, L.

    2006-02-01

    The H-bonded complexes of 2-aminopyrimidine (NH2Py) with parabenzoquinone (Qu) in a low-temperature argon matrix are investigated by the method of IR spectroscopy. The IR absorption spectra in the spectral range 400-3600cm-1 are obtained for different concentration ratios of these compounds at a temperature of 11K. The molar integrated absorption coefficients in the bands of the stretching modes of the free and H-bonded NH2 group are determined. Quantum-mechanical calculations of the IR spectra of the NH2Py and Qu molecules and their dimers are carried out. A comparison of the experimental and calculated results permits the conclusion that NH2Py-Qu dimers in an argon matrix have a planar structure with two weak hydrogen bonds, NH ⋯O and CH ⋯N.

  2. Low-pressure argon adsorption assessment of micropore connectivities in activated carbons.

    Science.gov (United States)

    Zimny, T; Villieras, F; Finqueneisel, G; Cossarutto, L; Weber, J V

    2006-01-01

    Low-pressure argon adsorption has been used to study the energetic distribution of microporous activated carbons differing by their burn-off. The collected isotherms were analyzed using the derivative isotherm summation method. Some oscillations on the experimental curves for very low partial pressures were detected. The results are analyzed and discussed according to the literature and could be attributed to local overheating caused by spontaneous mass transfer of argon through constrictions between former pores and the new opening pore or deadend pores. We used the dynamic character of the experimental method and mainly the discrepancy of the quasi-equilibrium state to deduce key parameters related to the porosity topology. PMID:16112680

  3. CFD Simulation of a Hydrogen/Argon Plasma Jet Reactor for Coal Pyrolysis

    Institute of Scientific and Technical Information of China (English)

    CHEN H. G.; XIE K. C.

    2004-01-01

    A Computational Fluid Dynamics (CFD) model was formulated for DC arc hydrogen/argon plasma jet reactors used in the process of the thermal H2/Ar plasma pyrolysis of coal to acetylene. In this model, fluid flow, convective heat transfer and conjugate heat conductivity are considered simultaneously. The error caused by estimating the inner-wall temperature of a reactor is avoided. The thermodynamic and transport properties of the hydrogen/argon mixture plasma system, which are usually expressed by a set of discrete dats, are fitted into expressions that can be easily implemented in the program. The effects of the turbulence are modeled by two standard k-s equations. The temperature field and velocity field in the plasma jet reactor were calculated by employing SIMPLEST algorithm. The knowledge and insight obtained are useful for the design improvement and scale-up of plasma reactors.

  4. Novel Diamond Films Synthesis Strategy: Methanol and Argon Atmosphere by Microwave Plasma CVD Method Without Hydrogen

    Science.gov (United States)

    Yang, Li; Jiang, Caiyi; Guo, Shenghui; Zhang, Libo; Gao, Jiyun; Peng, Jinhui; Hu, Tu; Wang, Liang

    2016-09-01

    Diamond thin films are grown on silicon substrates by only using methanol and argon mixtures in microwave plasma chemical vapor deposition (MPCVD) reactor. It is worth mentioning that the novel strategy makes the synthesis reaction works smoothly without hydrogen atmosphere, and the substrates temperature is only 500 °C. The evidence of surface morphology and thickness under different time is obtained by characterizing the samples using scanning electron microscopy (SEM). X-ray diffractometer (XRD) spectrum reveals that the preferential orientation of (111) plane sample is obtained. The Raman spectra indicate that the dominant component of all the samples is a diamond. Moreover, the diamond phase content of the targeted films was quantitatively analyzed by X-ray photoelectron spectroscopy (XPS) method, and the surface roughness of diamond films was investigated by atomic force microscope (AFM). Meanwhile, the possible synthesis mechanism of the diamond films in methanol- and argon-mixed atmosphere was discussed.

  5. Performance and emission characteristics of the thermal barrier coated SI engine by adding argon inert gas to intake mixture.

    Science.gov (United States)

    Karthikeya Sharma, T

    2015-11-01

    Dilution of the intake air of the SI engine with the inert gases is one of the emission control techniques like exhaust gas recirculation, water injection into combustion chamber and cyclic variability, without scarifying power output and/or thermal efficiency (TE). This paper investigates the effects of using argon (Ar) gas to mitigate the spark ignition engine intake air to enhance the performance and cut down the emissions mainly nitrogen oxides. The input variables of this study include the compression ratio, stroke length, and engine speed and argon concentration. Output parameters like TE, volumetric efficiency, heat release rates, brake power, exhaust gas temperature and emissions of NOx, CO2 and CO were studied in a thermal barrier coated SI engine, under variable argon concentrations. Results of this study showed that the inclusion of Argon to the input air of the thermal barrier coated SI engine has significantly improved the emission characteristics and engine's performance within the range studied. PMID:26644918

  6. Investigation of transfer ionization processes in the collision of partially stripped carbon ions on Argon

    Institute of Scientific and Technical Information of China (English)

    WANG Jun; Du Juan; SUN GuangZhi; CHEN Lin; CHEN XiMeng; DING BaoWei; FU HongBin; CUI Ying; SHAO JianXiong; LU YanXia; GAO ZhiMin; LIU YuWen

    2008-01-01

    The ratios of the cross section of the transfer-ionization to the single-electroncapture of Argon induced by Cq+ (q=1,2,3) ions are measured by means of position sensitive and time-of-flight techniques. Our experimental results are compared with the data of Heq+ (q=1,2)-Ar of DuBois. A qualitative interpretation is presented based on the Classical-Over-Barrier Model of Bohr,

  7. EBR-II argon cooling system restricted fuel handling I and C upgrade

    International Nuclear Information System (INIS)

    The instrumentation and control of the Argon Cooling System (ACS) restricted fuel handling control system at Experimental Breeder Reactor II (EBR-II) is being upgraded from a system comprised of many discrete components and controllers to a computerized system with a graphical user interface (GUI). This paper describes the aspects of the upgrade including reasons for the upgrade, the old control system, upgrade goals, design decisions, philosophies and rationale, and the new control system hardware and software

  8. The WArP Experiment: A Double-Phase Argon Detector for Dark Matter Searches

    OpenAIRE

    Andrea Zani

    2014-01-01

    Cryogenic noble liquids emerged in the previous decade as one of the best media to perform WIMP dark matter searches, in particular due to the possibility to scale detector volumes to multiton sizes. The WArP experiment was then developed as one of the first to implement the idea of coupling Argon in liquid and gas phase, in order to discriminate β/γ -interactions from nuclear recoils and then achieve reliable background rejection. Since its construction, other projects spawned, employing Arg...

  9. Gas temperature effect on the time for onset of particle nucleation in argon diluted acetylene plasma

    CERN Document Server

    Stefanovic, I; Berndt, J; Winter, J; Stefanovic, Ilija; Kovacevic, Eva; Berndt, Johannes; Winter, Jorg

    2004-01-01

    In our work we are focused on study of powder formation in C2H2/Ar plasmas. In this scope we used a combination of FTIR and mass spectroscopy, which are the mostly used experimental techniques for plasma powder formation diagnostics. To test the proposed mechanism for particle nucleation delay we measured the particle nucleation under different plasma conditions: firstly we increased the gas temperature and secondly we changed the background gas from argon to helium.

  10. Performance of VUV-sensitive MPPC for liquid argon scintillation light

    Science.gov (United States)

    Igarashi, T.; Tanaka, M.; Washimi, T.; Yorita, K.

    2016-10-01

    A new multi-pixel photon counter (MPPC) sensitive to vacuum ultra-violet (VUV) light (wavelength λ dark count rate of the MPPCs are also evaluated. Using an 241Am α-ray source, the absolute photon detection efficiency (PDE) of the liquid argon (LAr) scintillation light (λ=128 nm) for the latest MPPC model is estimated to be 13%. Based on these basic measurements a possible application of the new MPPC to LAr detectors in dark matter search is suggested.

  11. Alternating-Gradient Focusing of the Benzonitrile-Argon Van der Waals Complex

    OpenAIRE

    Putzke, S.; Filsinger, F.; Küpper, J.; Meijer, G.

    2012-01-01

    We report on the focusing and guiding of the van der Waals complex formed between benzonitrile molecules (C$_6$H$_5$CN) and argon atoms in a cold molecular beam using an ac electric quadrupole guide. The distribution of quantum states in the guided beam is non-thermal, because the transmission efficiency depends on the state-dependent effective dipole moment in the applied electric fields. At a specific ac frequency, however, the excitation spectrum can be described by a thermal distribution ...

  12. Upgraded Readout Electronics for the ATLAS Liquid Argon Calorimeters at the High Luminosity LHC

    Science.gov (United States)

    Andeen, Timothy R.; ATLAS Liquid Argon Calorimeter Group

    2012-12-01

    The ATLAS liquid-argon calorimeters produce a total of 182,486 signals which are digitized and processed by the front-end and back-end electronics at every triggered event. In addition, the front-end electronics sum analog signals to provide coarsely grained energy sums, called trigger towers, to the first-level trigger system, which is optimized for nominal LHC luminosities. However, the pile-up background expected during the high luminosity phases of the LHC will be increased by factors of 3 to 7. An improved spatial granularity of the trigger primitives is therefore proposed in order to improve the identification performance for trigger signatures, like electrons or photons, at high background rejection rates. For the first upgrade phase in 2018, new Liquid Argon Trigger Digitizer Boards are being designed to receive higher granularity signals, digitize them on detector and send them via fast optical links to a new, off-detector digital processing system. The digital processing system applies digital filtering and identifies significant energy depositions. The refined trigger primitives are then transmitted to the first level trigger system to extract improved trigger signatures. The general concept of the upgraded liquid-argon calorimeter readout together with the various electronics components to be developed for such a complex system is presented. The research activities and architectural studies undertaken by the ATLAS Liquid Argon Calorimeter Group are described, particularly details of the on-going design of mixed-signal front-end electronics, of radiation tolerant optical-links, and of the high-speed off-detector digital processing system.

  13. One more study of argon arc binding to pure tungsten cathode

    Science.gov (United States)

    Gadzhiev, M. Kh.; Sargsyan, M. A.; Tereshonok, D. V.; Tyuftyaev, A. S.

    2016-08-01

    Pyrometric and spectroscopic investigations of pure tungsten cathode in argon arc plasma discharge at atmospheric pressure are reported. The distribution of surface cathode temperature and the radial distribution of plasma temperature at different distance from the cathode tip were measured. We conducted a comparison between our work and other studies on arc discharges where cathodes from lanthanated (W-2% La2O3) and thoriated (W-2% ThO2) tungsten were used.

  14. Characterisation of an RF excited argon plasma cathode electron beam gun

    OpenAIRE

    Del Pozo, S.; Ribton, C; Smith, DR

    2014-01-01

    This work describes the experimental set up used for carrying out spectroscopic measurements in a plasma cathode electron beam (EB) gun. Advantages of plasma cathode guns over thermionic guns are described. The factors affecting electron beam power such as plasma pressure, excitation power and plasma chamber geometry are discussed. The maximum beam current extracted was 53 mA from a 0.5 mm diameter aperture in the plasma chamber. In this work, the electron source is an argon plasma excited at...

  15. Electron localizability indicators ELI and ELIA: the case of highly correlated wavefunctions for the argon atom.

    Science.gov (United States)

    Bezugly, Viktor; Wielgus, Pawel; Wagner, Frank R; Kohout, Miroslav; Grin, Yuri

    2008-06-01

    Electron localizability indicators based on the same-spin electron pair density and the opposite-spin electron pair density are studied for correlated wavefunctions of the argon atom. Different basis sets and reference spaces are used for the multireference configuration interaction method following the complete active space calculations aiming at the understanding of the effect of local electron correlation when approaching the exact wavefunction. The populations of the three atomic shells of Ar atom in real space are calculated for each case.

  16. Evaluation of the procedures in BR 3014 for the assessment of Argon-41 activity in air

    International Nuclear Information System (INIS)

    This report discusses conflicting measurements which have been made at RNC Greenwich using a 92 cc Argon-41 collection chamber in the detecting assembly MK 5NHA with the counter scaler MK 4NCA. It is concluded that the original calibration is not in serious error but it is recommended that the calibration factor should be increased by 27% over that given in BR 3014. (author)

  17. Effect of argon on the performance of a fast-axial flow CO2 laser

    Science.gov (United States)

    Jelvani, S.; Amiri, Kh; Pazokian, H.; Montazerolghaem, M.; Mollabashi, M.; Naeimi, S. A.; Esmaeilpour, D.

    2011-01-01

    The performance characteristics of a fast-axial flow (FAF) cw CO2 laser are described. The dependences of the output power, efficiency, and discharge voltage on the discharge current of a FAF cw CO2 laser with optimised composition of the CO2:N2:He=1:4.4:7.6 gas mixture with a small amount of argon are studied experimentally at two pressures of 50 and 60 mbar in open and closed cycle regimes of the laser system.

  18. Fano factor in gaseous argon measured by the proportional scintillation method

    International Nuclear Information System (INIS)

    It is found that the apparent Fano factor in argon obtained by using 5.90 keV X-rays with the proportional scintillation method depends on the gas pressure and that the true Fano factor can be obtained by extrapolating the linear relation between the apparent Fano factor and the reciprocal of the gas pressure. The Fano factor thus obtained gives good agreement, within experimental errors, with the value recently obtained by using a gridded ionization chamber. (orig.)

  19. Experimental investigation of MHD impact on argon plasma flows by variation of magnetic flux density

    OpenAIRE

    Knapp, A.; Fulge, Hannes; Herdrich, Georg; Ono, N.; Wernitz, Ricarda; AUWETER-KURTZ, Monika; Röser, Hans-Peter; Fasoulas, Stefanos

    2012-01-01

    The interaction between a probe body and argon plasma flow is investigated to examine to what extent the probe head temperature and the bow shock distance can be influenced by applying a strong magnetic field. The experiments are performed using a strong permanent magnet installed inside a probe body with a spherical, coated probe head. Former investigations showed strong influence on the bow shock geometry but also on the inflow plasma jet. Several boundary conditions have been varied to eva...

  20. Bronchial asthma control after argon plasma coagulation turbinectomy in patients with chronic rhinitis

    OpenAIRE

    Jura-Szołtys, Edyta; Ficek, Rafał; Ficek, Joanna; Markowski, Jarosław; Chudek, Jerzy

    2013-01-01

    Bronchial asthma is frequently accompanied by chronic rhinitis. It has been observed that effective treatment of rhinitis may reduce asthma symptoms. The aim of the study was the evaluation of the control of bronchial asthma symptoms in patients with chronic rhinitis after argon plasma coagulation turbinectomy (APCt). The effect of APCt was assessed in 47 adults with drug-resistant chronic rhinitis and bronchial asthma 3-month post-procedure. Changes of asthma symptoms were scored using Asthm...

  1. The lead-liquid argon sampling calorimeter of the SLD detector

    Energy Technology Data Exchange (ETDEWEB)

    Axen, D.; Bougerolle, S.; Sobie, R. (Univ. British Columbia, Vancouver, BC (Canada)); Eigen, G.; De Jongh, F.; Hitlin, D.; Kelsey, M.; Klein, M.; Mincer, A.; Wisniewski, W.; Wolf, R. (California Inst. of Technology, Pasadena, CA (United States)); Arroyo, C.; Au, Y.; Baltay, C.; Bolton, T.; Bazarko, A.; Camilleri, L.; Hyatt, E.; Manly, S.; Rabinowitz, S.; Rowson, P.C.; Seligman, S.; Shaevitz, M.H.; Smith, S.; Steiner, R.V. (Columbia Univ., Nevis Lab., Irvington, NY (United States)); Abt, I.; Alzofon, D.; Arnett, D.; Barrera, F.; Bell, R.; Bes, S.C.; Bogart, J.; Breidenbach, M.; Candia, A.; Claus, R.; Cutler, H.; Davis, R.; Dubois, R.; Foss, M.; Fox, J.; Fox, M.; Gioumousis, A.; Grebenyuk, A.; Haller, G.; Hamilton, V.; Hodgson, J.; Huffer, M.; Junk, T.; Kim, P.; Labs, J.; Neal, H.; Nelson, D.; Nordby, M.; Paffrath, L.; Putallaz, G.; Rogers, H.; Russell, J.J.; Saez, P.; Seward, P.; Sherden, D.; Skarpaas, K.; Schindler, R.H.; Waite, A.P.; Watt, R. (Stanford Linear Accelerator Center, CA

    1993-05-01

    The lead-liquid argon sampling calorimeter of the SLD detector is one of the largest detectors employing cryogenic liquids now in operation. This paper details the design and performance considerations, the mechanical and cryogenic systems, the absorber design and tower segmentation, the data acquisition electronics, and the control systems of the detector. The initial operational performance of the device is discussed. Detailed resolution studies will be presented in a later paper. (orig.).

  2. Increased Efficiency in SI Engine with Air Replaced by Oxygen in Argon Mixture

    Energy Technology Data Exchange (ETDEWEB)

    Killingsworth, N J; Rapp, V H; Flowers, D L; Aceves, S M; Chen, J; Dibble, R

    2010-01-13

    Basic engine thermodynamics predicts that spark ignited engine efficiency is a function of both the compression ratio of the engine and the specific heat ratio of the working fluid. In practice the compression ratio of the engine is often limited due to knock. Both higher specific heat ratio and higher compression ratio lead to higher end gas temperatures and increase the likelihood of knock. In actual engine cycles, heat transfer losses increase at higher compression ratios and limit efficiency even when the knock limit is not reached. In this paper we investigate the role of both the compression ratio and the specific heat ratio on engine efficiency by conducting experiments comparing operation of a single-cylinder variable-compression-ratio engine with both hydrogen-air and hydrogen-oxygen-argon mixtures. For low load operation it is found that the hydrogen-oxygen-argon mixtures result in higher indicated thermal efficiencies. Peak efficiency for the hydrogen-oxygen-argon mixtures is found at compression ratio 5.5 whereas for the hydrogen-air mixture with an equivalence ratio of 0.24 the peak efficiency is found at compression ratio 13. We apply a three-zone model to help explain the effects of specific heat ratio and compression ratio on efficiency. Operation with hydrogen-oxygen-argon mixtures at low loads is more efficient because the lower compression ratio results in a substantially larger portion of the gas to reside in the adiabatic core rather than in the boundary layer and in the crevices, leading to less heat transfer and more complete combustion.

  3. Investigation of transfer ionization processes in the collision of partially stripped carbon ions on Argon

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The ratios of the cross section of the transfer-ionization to the single-electron-capture of Argon induced by Cq+ (q=1,2,3) ions are measured by means of position sensitive and time-of-flight techniques. Our experimental results are compared with the data of Heq+ (q=1,2)-Ar of DuBois. A qualitative interpretation is presented based on the Classical-Over-Barrier Model of Bohr.

  4. A measurement of E/. pi. for a fast lead liquid argon calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Makowiecki, D.; Gordon, H.A.; Ma, H.; Murtagh, M.; Radeka, V.; Rahm, D.; Rescia, S. (Brookhaven National Lab., Upton, NY (United States)); Abrams, G.S.; Groom, D.E.; Kirsten, F.; Levi, M.; Siegrist, J. (Lawrence Berkeley Lab., CA (United States)); Amako, K.; Inaba, O.; Kondo, T. (National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)); Baden, A.R.; Fong, D.; Hadley, N.; Kunori, S.; Skuja, A. (Maryland U

    1990-01-01

    The NA34 (HELIOS) calorimeter has measured e/{pi} {congruent} 1.1 in a uranium/liquid argon calorimeter with a shaping time of 135 nsec. Lead may be a viable alternative, but e/{pi} must first be measured at fast shaping times in lead. We re preparing to measure e/{pi} at momenta ranging from 0.5 to 20 GeV/c and with shaping times of 50, 100 and 150 nsec.

  5. A measurement of E/{pi} for a fast lead liquid argon calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Makowiecki, D.; Gordon, H.A.; Ma, H.; Murtagh, M.; Radeka, V.; Rahm, D.; Rescia, S. [Brookhaven National Lab., Upton, NY (United States); Abrams, G.S.; Groom, D.E.; Kirsten, F.; Levi, M.; Siegrist, J. [Lawrence Berkeley Lab., CA (United States); Amako, K.; Inaba, O.; Kondo, T. [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Baden, A.R.; Fong, D.; Hadley, N.; Kunori, S.; Skuja, A. [Maryland Univ., College Park, MD (United States); Bowen, T.; Forden, G.; Jenkins, E.; Johns, K.; Rutherfoord, J.; Shupe, M. [Arizona Univ., Tucson, AZ (United States); Burnett, T.; Cook, V.; Davisson, R.; Mockett, P.; Rothberg, J.; Williams, R.W. [Washington Univ., Seattle, WA (United States); Cremaldi, L.; Reidy, J.; Summers, D. [Mississippi Univ., University, MS (United States); DiGiacomo, N. [Martin Marietta Aerospace, Denver, CO (United States). Astronautics Group; Draper, P.; Ferbel, T.; Lobkowicz, F. [Rochester Univ., NY (United States); Faust, J.; Hauptman, J.; Pang, M. [Iowa State Univ. of Science and Technology, Ames, IA (United States); Gabriel, T.A. [Oak Ridge National Lab., TN (United States); Hagopian, V.; Womersley, J. [Florida State Univ., Tallahassee, FL (United States); Handler, T. [Tennessee Univ., Knoxville, TN (United States); Hitlin, D. [California Inst. of Tech., Pasadena, CA (United States); Mulholland, G.T. [Fermi National Accelerator Lab., Batavia, IL (United States); Watanabe, Y. [Tokyo Inst. of Tech. (Japan); Weerts, H. [Michigan State Univ., East Lansing, MI (United States)

    1990-12-31

    The NA34 (HELIOS) calorimeter has measured e/{pi} {congruent} 1.1 in a uranium/liquid argon calorimeter with a shaping time of 135 nsec. Lead may be a viable alternative, but e/{pi} must first be measured at fast shaping times in lead. We re preparing to measure e/{pi} at momenta ranging from 0.5 to 20 GeV/c and with shaping times of 50, 100 and 150 nsec.

  6. Influence of gas discharge parameters on emissions from a dielectric barrier discharge excited argon excimer lamp

    OpenAIRE

    Mike Collier; Erich Rohwer; Timo Stehmann; Hubertus M. von Bergmann; Dumisani J. Hlatywayo; Peter Baricholo

    2011-01-01

    A dielectric barrier discharge excited neutral argon (Ar I) excimer lamp has been developed and characterised. The aim of this study was to develop an excimer lamp operating at atmospheric pressure that can replace mercury lamps and vacuum equipment used in the sterilisation of medical equipment and in the food industry. The effects of discharge gas pressure, flow rate, excitation frequency and pulse width on the intensity of the Ar I vacuum ultraviolet (VUV) emission at 126 nm and near infra...

  7. Liquid Argon Calorimeters Operation and Data Quality During the 2015 Proton Run

    CERN Document Server

    Camincher, Clement; The ATLAS collaboration

    2016-01-01

    In 2015 ATLAS operated with an excellent efficiency, recording an integrated luminosity of 3.9fb^{-1} at \\sqrt{s} = 13 TeV. The Liquid Argon (LAr) Calorimeter contributed to this effort by operating with a good data quality efficiency of 99.4% . This poster highlights the overall status, performances and data quality of the LAr Calorimeters during the first year of Run-2 operations.

  8. Performance Of A Liquid Argon Time Projection Chamber Exposed To The WANF Neutrino Beam

    CERN Document Server

    Arneodo, F; Bonesini, M; Borio di Tigliole, A; Boschetti, B; Bueno, A; Calligarich, E; Casagrande, F; Cavalli, D; Cavanna, F; Cennini, P; Centro, Sandro; Cesana, E; Cline, D; Curioni, A; De Mitri, I; De Vecchi, C; Dolfini, R; Ferrari, A; Ghezzi, A; Guglielmi, A; Kisiel, J; Mannocchi, G; Martinez de la Ossa, A; Matthey, C; Mauri, F; Montanari, C; Navas, S; Negri, P; Nicoletto, Marino; Otwinowski, S; Paganoni, M; Palamara, O; Pepato, Adriano; Periale, L; Piano Mortari, G; Picchi, P; Pietropaolo, F; Puccini, A; Pullia, A; Ragazzi, S; Rancati, T; Rappoldi, A; Raselli, G L; Redaelli, N; Rondio, E; Rubbia, André; Rubbia, Carlo; Sala, P R; Sergiampietri, F; Sobczyk, J; Suzuki, S; Tabarelli de Fatis, T; Terrani, M; Terranova, F; Tonazzo, A; Ventura, Sandro; Vignoli, C; Wang, H; Zalewska A

    2006-01-01

    We present the results of the first exposure of a Liquid Argon TPC to a multi-GeV neutrino beam. The data have been collected with a 50 liters ICARUS-like chamber located between the CHORUS and NOMAD experiments at the CERN West Area Neutrino Facility (WANF). We discuss both the instrumental performance of the detector and its capability to identify and reconstruct low multiplicity neutrino interactions.

  9. Relativistic configuration-interaction calculation of $K\\alpha$ transition energies in beryllium-like argon

    CERN Document Server

    Yerokhin, V A; Fritzsche, S

    2014-01-01

    Relativistic configuration-interaction calculations have been performed for the energy levels of the low-lying and core-excited states of beryllium-like argon, Ar$^{14+}$. These calculations include the one-loop QED effects as obtained by two different methods, the screening-potential approach as well as the model QED operator approach. The calculations are supplemented by a systematic estimation of uncertainties of theoretical predictions.

  10. Measurement of neutrino interactions in gaseous argon with T2K

    CERN Document Server

    ,

    2016-01-01

    The T2K near-detector, ND280, employs three large argon gas TPCs (Time Projection Chambers) for particle tracking and identification. The gas inside the TPCs can be used as an active target to study the neutrino interactions in great detail. The low density of the gas leads to very low track energy thresholds, allowing the reconstruction of very low momentum tracks, e.g. protons with kinetic energies down to $\\mathcal{O}$(1 MeV). Since different nuclear interaction models vary considerably in their predictions of those low momentum track multiplicities, this makes neutrino interactions on gases a powerful probe to test those models. The TPCs operate with an argon-based gas mixture (95% by volume) and have been exposed to the T2K neutrino beam since the beginning of the experiment in 2010. Due to the low total mass of the gas, neutrino argon interactions happen only rarely, compared to the surrounding scintillator-based detectors. We expect about 600 such events in the recorded data so far (about 200 in the fi...

  11. Photoelectron yield in the prototype of the liquid argon detector for CDEX-10

    CERN Document Server

    Chen, Qing-Hao; Cheng, Jian-Ping; Kang, Ke-Jun; Li, Yuan-Jing; Lin, Shin-Ted; Tang, Chang-Jian; Xing, Hao-Yang; Yu, Xun-Zhen; Zeng, Ming

    2015-01-01

    The China Dark Matter Experiment (CDEX) is a low background experiment at China Jinping Underground Laboratory (CJPL) designed to directly detect dark matter with a high-purity germanium (HPGe) detector. In the second phase CDEX-10 with 10 kg germanium array detector system, the liquid argon (LAr) anti-Compton active shielding and cooling system is proposed. For purpose of studying the properties of LAr detector, a prototype with an active volume of 7 liters of liquid argon was built and operated. The photoelectron yields, as a critically important parameter for the LAr detector, have been measured to be 0.051-0.079 p.e./keV for 662 keV gamma lines at different positions. The good agreement between the experimental and simulation results has provided a quite reasonable understanding and determination of the important parameters such as the Surviving Fraction of the $Ar_{2}^{*}$ excimers, the absorption length for 128 nm photons in liquid argon, the reflectivity of Teflon and so on.

  12. Waves generated in the vicinity of an argon plasma gun in the ionosphere

    Science.gov (United States)

    Cahill, L. J., Jr.; Arnoldy, R. L.; Lysak, R. L.; Peria, W.; Lynch, K. A.

    1993-01-01

    Wave and particle observations were made in the close vicinity of an argon plasma gun carned to over 600 km altitude on a sounding rocket. The gun was carned on a subpayload, separated from the main payload early in the flight. Twelve-second argon ion ejections were energized alternately with a peak energy of 100 or 200 eV. They produced waves, with multiple harmonics, in the range of ion cyclotron waves, 10 to 1000 Hz at rocket altitudes. Many of these waves could not be identified as corresponding to the cyclotron frequencies of any of the ions, argon or ambient, known to be present. In addition, the wave frequencies were observed to rise and fall and to change abruptly during a 12-s gun operation. The wave amplitudes, near a few hundred Hertz, were of the order of O. 1 V/m. Some of the waves may be ion-ion hybrid waves. Changes in ion populations were observed at the main payload and at the subpayload during gun operations. A gun-related, field-aligned, electron population also appeared.

  13. Performance of bare high-purity germanium detectors in liquid argon for the GERDA experiment

    CERN Document Server

    Heider, Marik Barnabé; Chkvorets, Oleg; Di Vacri, Assunta; Gusev, Konstantin; Schönert, Stefan; Shirchenko, Mark

    2008-01-01

    The GERmanium Detector Array, GERDA, will search for neutrinoless double beta decay in 76Ge at the National Gran Sasso Laboratory of the INFN. Bare high-purity germanium detectors enriched in 76Ge will be submerged in liquid argon serving simultaneously as a shield against external radioactivity and as a cooling medium. In GERDA Phase-I, reprocessed enriched-Ge detectors, which were previously operated by the Heidelberg-Moscow and IGEX collaborations, will be redeployed. Before operating the enriched detectors, tests are performed with non-enriched bare HPGe detectors in the GERDA underground Detector Laboratory to test the Phase-I detector assembly, the detector handling protocols, the refurbishment technology and to study the long-term stability in liquid argon. The leakage currents in liquid argon and liquid nitrogen have been extensively studied under varying gamma irradiation conditions. In total three non-enriched high-purity p-type prototype germanium detectors have been operated successfully. The dete...

  14. LArGe - Active background suppression using argon scintillation for the GERDA $0\

    CERN Document Server

    Agostini, M; Budjáš, D; Cattadori, C; Gangapshev, A; Gusev, K; Heisel, M; Junker, M; Klimenko, A; Lubashevskiy, A; Pelczar, K; Schönert, S; Smolnikov, A; Zuzel, G

    2015-01-01

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for future application in the GERDA experiment. Similar to GERDA, LArGe operates bare germanium detectors submersed into liquid argon (1 m$^3$, 1.4 tons), which in addition is instrumented with photomultipliers to detect argon scintillation light. The scintillation signals are used in anti-coincidence with the germanium detectors to effectively suppress background events that deposit energy in the liquid argon. The background suppression efficiency was studied in combination with a pulse shape discrimination (PSD) technique using a BEGe detector for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times $10^3$ have been achieved. First background data of LArGe with a coaxial HPGe detector (without PSD) yield a background index of (0.12$-$4.6)$\\cdot 10^{-2}$ cts/(keV$\\cdot$kg$\\cdot$y) (90% C.L.), which is at the level of GERDA Phase I. Fu...

  15. Impact of an atmospheric argon plasma jet on a dielectric surface and desorption of organic molecules

    Science.gov (United States)

    Damany, Xavier; Pasquiers, Stéphane; Blin-Simiand, Nicole; Bauville, Gérard; Bournonville, Blandine; Fleury, Michel; Jeanney, Pascal; Santos Sousa, João

    2016-08-01

    The propagation of a DC-pulsed argon plasma jet through the surrounding ambient air, and its interaction with an ungrounded glass plate placed on the jet trajectory, was studied by means of fast imaging. The surface plays an important role in the spatio-temporal characteristics of the plasma. Indeed, for an argon jet propagating perpendicularly to the surface, the plasma jet structure changes from filamentary to diffuse when the distance between the nozzle of the capillary tube and the surface is short (≤10 mm). Changing the angle between the capillary tube and the glass plate, and varying the gas flow rate strongly affects the spatial extension of the plasma that develops on the surface. This surface plasma propagates while the plasma in the argon jet is maintained with the same luminous intensity. Finally, this plasma jet shows interesting characteristics for desorption of low volatile organic molecules such as bibenzyl. A maximum removal of bibenzyl is located at the intersection area between the jet axis and the glass surface, and some of the initially deposited molecules are found intact in gas phase. Contribution to the topical issue "6th Central European Symposium on Plasma Chemistry (CESPC-6)", edited by Nicolas Gherardi, Ester Marotta and Cristina Paradisi

  16. Ab initio calculations of many-body interactions for compressed solid argon.

    Science.gov (United States)

    Tian, Chunling; Liu, Fusheng; Cai, Lingcang; Yuan, Hongkuan; Chen, Hong; Zhong, Mingmin

    2015-11-01

    An investigation on many-body effects of solid argon at high pressure was conducted based on a many-body expansion of interaction energy. The three- and four-body terms in the expansion were calculated using the coupled-cluster method with single, double, and noniterative triple theory and incremental method, in which the configurations of argon trimers and tetramers were chosen as the same as those in the actual lattice. The four-body interactions in compressed solid argon were estimated for the first time, and the three-body interaction ab initio calculations were extended to a small distance. It shows that the four-body contribution is repulsive at high densities and effectively cancels the three-body lattice energy. The dimer potential plus three-body interaction can well reproduce the measurements of equation of state at pressure approximately lower than ∼60 GPa, when including the four-body effects extends the agreement up to the maximum experimental pressure of 114 GPa. PMID:26547175

  17. CAPTAIN-Minerνa. Neutrino-Argon Scattering in a Medium-Energy Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Mauger, Christopher M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-29

    The NuMI facility at Fermilab is currently providing an extremely intense beam of neutrinos for the NOνA, MINERνA and MINOS+ experiments. By installing the 5-ton CAPTAIN liquid argon TPC in front of the MINERνA detector in the NuMI beamline and combining the data from the CAPTAIN, MINERνA and MINOS+ detectors, a broad program of few-GeV neutrino cross section measurements on argon can be pursued. These measurements will be extremely helpful for future oscillation experiments. By directly comparing the cross sections on argon to MINERνA’s scintillator (CH) target, a new level of precision can be achieved in the measurements of the effects of the nucleus on neutrino interactions. These effects are of interest to not only the particle physics but also the nuclear physics community. This document describes in detail the physics goals of the CAPTAIN-MINERνA experiment, in addition to a first estimate of the technical resources required to install, commission and operate the CAPTAIN detector in front of the MINERVA detector.

  18. Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature

    CERN Document Server

    Acciarri, R; Boffelli, F; Cambiaghi, M; Canci, N; Cavanna, F; Cocco, A G; Di Pompeo, F; Fiorillo, G; Galbiati, C; Grandi, L; Kryczynski, P; Meng, G; Montanari, C; Palamara, O; Pandola, L; Perfetto, F; Mortari, G B Piano; Pietropaolo, F; Raselli, G L; Rossella, M; Rubbia, C; Segreto, E; Szelc, A M; Triossi, A; Ventura, S; Vignoli, C; Zani, A

    2011-01-01

    Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photo multiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these testes the Hamamatsu PMTs showed superb performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detec...

  19. Results of argon laser exposure of capillary hemangiomas of infancy--preliminary report.

    Science.gov (United States)

    Apfelberg, D B; Greene, R A; Maser, M R; Lash, H; Rivers, J L; Laub, D R

    1981-02-01

    Argon laser photocoagulation of capillary hemangiomas of infancy ("strawberry marks") has been described in three cases. Treatment in the first case was necessitated by repeated alarming hemorrhage. The second case was treated totally and resulted in immediate induced resolution of the hemangioma, which preceded (by 9 months) the spontaneous involution of an untreated control comparison area and resulted in virtually complete blanching without secondary deformity. The third case demonstrated the laser's ability to stop rapid growth immediately. Spontaneous involution then ensued naturally and was complete 12 months later. It should be emphasized that the argon laser is not recommended for the routine treatment of a normally spontaneously involuting hemangioma. Each case must be examined and the usual indications for intervention should be present. The argon laser has demonstrated the ability to coagulate vascular lesions such as port wine hemangiomas and telangiectasias and can be expected to have a similar favorable effect on the aggressive, rapidly expanding juvenile hemangioma, although further clinical documentation clearly remains to be demonstrated. PMID:7465667

  20. The ICARUS T600 Liquid Argon Detector Operation in the Underground Gran Sasso Laboratory

    CERN Document Server

    Vignoli, C

    2014-01-01

    The ICARUS T600 Module is the largest liquid argon detector (760 t LAr mass) ever realized to study neutrino oscill ations and matter stability in the deep underground Gran Sasso Laboratory. One of t he key elements for the detector performance is the liquid argon purity: residual electronegative compounds in argon have to be kept as low as 0.1 part s per billion all over the detector run. The T600 Module design was finalized by the ICARUS Collaboration after years of R&D studies that brought to the viable and scalable industrial solutions necessary for sized experiments with severe safety prescriptions for the underground operation . We present the T600 Module successful commissioning and the 3-years efficient, stable and continuous operation with extraordinary LAr purity, high performance and zero dead time data taking . This result demonstrates for the first time the feasibility of activation and long-term run in safe conditions of sized cryogenic detectors even in a confined underground location and r...

  1. A preliminary report on methods of measuring and reducing Argon-41 production by a TRIGA reactor

    International Nuclear Information System (INIS)

    Methods to accurately determine and techniques to reduce the Argon-41 released from the one-megawatt Geological Survey TRIGA Reactor facility have been developed. Knowledge of the composition of the exhaust-gas effluent is of prime importance to the U.S. Geological Survey in minimizing all radioactive releases to the environment. The counting systems and control measures have enabled the Geological Survey TRIGA Reactor staff to reduce the amount of Argon-41 released from the facility by a factor of two, with no reduction in operation level of the reactor. The counting system has also enabled the staff to categorize the principal sources of Argon-41. Under normal conditions, a fully-loaded rotating-specimen rack is by far the largest contributor. With the current counting system, 10-7 microcuries per cubic centimeter can be detected in the exhaust stack. It is intended to further improve this system to increase both the sensitivity and the reliability. The sensitivity is expected to be increased by utilizing a larger counting volume. To improve the reliability, it is planned to fabricate a loop parallel to the exhaust system, eliminating the need for a separate pump. (author)

  2. Investigation of argon ion sputtering on the secondary electron emission from gold samples

    Science.gov (United States)

    Yang, Jing; Cui, Wanzhao; Li, Yun; Xie, Guibai; Zhang, Na; Wang, Rui; Hu, Tiancun; Zhang, Hongtai

    2016-09-01

    Secondary electron (SE) yield, δ, is a very sensitive surface property. The values of δ often are not consistent for even identical materials. The influence of surface changes on the SE yield was investigated experimentally in this article. Argon ion sputtering was used to remove the contamination from the surface. Surface composition was monitored by X-ray photoelectron spectroscopy (XPS) and surface topography was scanned by scanning electron microscope (SEM) and atomic force microscope (AFM) before and after every sputtering. It was found that argon sputtering can remove contamination and roughen the surface. An "equivalent work function" is presented in this thesis to establish the relationship between SE yield and surface properties. Argon ion sputtering of 1.5keV leads to a significant increase of so called "work function" (from 3.7 eV to 6.0 eV), and a decrease of SE yield (from 2.01 to 1.54). These results provided a new insight into the influence of surface changes on the SE emission.

  3. Calibration of liquid argon and neon detectors with $^{83}Kr^m$

    CERN Document Server

    Lippincott, W H; Gastler, D; Kastens, L W; Kearns, E; McKinsey, D N; Nikkel, J A

    2009-01-01

    We report results from tests of $^{83}$Kr$^{\\mathrm{m}}$, as a calibration source in liquid argon and liquid neon. $^{83}$Kr$^{\\mathrm{m}}$ atoms are produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\\mathrm{m}}$ scintillation peak at 41.5 keV appears in both liquids when filling our detector through a piece of zeolite coated with $^{83}$Rb. Based on this scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a resolution of 6% ($\\sigma$/E) and 3.0 photoelectrons/keV in liquid neon with a resolution of 19% ($\\sigma$/E). The observed peak intensity subsequently decays with the $^{83}$Kr$^{\\mathrm{m}}$ half-life after stopping the fill, and we find evidence that the spatial location of $^{83}$Kr$^{\\mathrm{m}}$ atoms in the chamber can be resolved. $^{83}$Kr$^{\\mathrm{m}}$ will be a useful calibration source for liquid argon and neon dark matter and solar neutrino detectors.

  4. Modifying the properties of fluorinated amorphous films using argon by filtered cathodic vacuum arc

    Science.gov (United States)

    Lin, Yu-Hung; Syue, Yang-Chih; Lin, Hong-Da; Chen, Uei-Shin; Chang, Yee-Shyi; Chen, Jiann-Ruey; Shih, Han C.

    2008-12-01

    Fluorine-doped amorphous carbon (a-C:F) films were deposited using a 90°-bend magnetic filtered cathodic arc plasma system with CF 4 as a precursor and the addition of argon gas. The microstructure, composition and chemical bonding nature of the a-C:F films were investigated by Raman scattering spectroscopy and X-ray photoelectron spectroscopy. The surface morphology and roughness of a-C:F films were observed through an atomic force microscope. Hardness was measured by nano-indentation. Water contact angles were measured by the sessile drop method. The fluorine content of the films increases with the argon flux. Because of the increase of the fluorine content in the films, the film surface becomes rougher; the hardness decreases, and the contact angle increases from 76.2° to 87.8°. This work demonstrates that an appropriate amount of the admitted argon to the plasma would promote the doping of the films with fluorine, and influences the properties of the a-C:F films.

  5. A correction to Birks' Law in liquid argon ionization chamber simulations for highly ionizing particles

    Energy Technology Data Exchange (ETDEWEB)

    Burdin, Sergey [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Horbatsch, Marko [Department of Physics and Astronomy, York University, Toronto, ON, M3J 1P3 (Canada); Taylor, Wendy, E-mail: taylorw@yorku.ca [Department of Physics and Astronomy, York University, Toronto, ON, M3J 1P3 (Canada)

    2012-02-01

    We present a study of the performance of Birks' Law in liquid argon ionization chamber simulations as applied to highly ionizing particles, such as particles with multiple electric charges or with magnetic charge. We used Birks' Law to model recombination effects in a GEANT4 simulation of heavy ions in a liquid argon calorimeter. We then compared the simulation to published heavy-ion data to extract a highly ionizing particle correction to Birks' Law.

  6. A G/NARRLI Effort. Measuring the Ionization Yield of Low-Energy Nuclear Recoils in Liquid Argon

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Tenzing Henry Yatish [Univ. of California, Berkeley, CA (United States)

    2014-01-01

    Liquid argon has long been used for particle detection due to its attractive drift properties, ample abundance, and reasonable density. The response of liquid argon to lowenergy O(102 -1044 eV) interactions is, however, largely unexplored. Weakly interacting massive particles such as neutrinos and hypothetical dark-matter particles (WIMPs) are predicted to coherently scatter on atomic nuclei, leaving only an isolated low-energy nuclear recoil as evidence. The response of liquid argon to low-energy nuclear recoils must be studied to determine the sensitivity of liquid argon based detectors to these unobserved interactions. Detectors sensitive to coherent neutrino-nucleus scattering may be used to monitor nuclear reactors from a distance, to detect neutrinos from supernova, and to test the predicted behavior of neutrinos. Additionally, direct detection of hypothetical weakly interacting dark matter would be a large step toward understanding the substance that accounts for nearly 27% of the universe. In this dissertation I discuss a small dual-phase (liquid-gas) argon proportional scintillation counter built to study the low-energy regime and several novel calibration and characterization techniques developed to study the response of liquid argon to low-energy O(102 -104 eV) interactions.

  7. The effect of argon laser irradiation on demineralization resistance of human enamel adjacent to orthodontic brackets: an in vitro study.

    Science.gov (United States)

    Noel, Lloyd; Rebellato, Joe; Sheats, Rose D

    2003-06-01

    Argon lasers, because of their significant timesavings over conventional curing lights, have been investigated for use in bonding orthodontic brackets. They are also being investigated for their ability to confer demineralization resistance on enamel, which is of great interest in orthodontics. A two-part in vitro study on 86 human posterior teeth was conducted to determine the effects of a five-second argon laser exposure on shear bond strength and to evaluate the effects of a five- and 10-second argon laser exposure (250 mW) on demineralization of enamel surrounding orthodontic brackets after exposure to an artificial caries bath. Brackets cured with the argon laser for five seconds yielded mean bond strengths similar to those attained with a 40-second conventional light-cured control (n = 13 per group, 20.4 vs 17.8 MPa). Brackets cured with the argon laser for 10 seconds resulted in significantly lower mean lesion depth when compared with a visible light control (n = 20 per group, 107.8 vs 137.2 microm, P = .038). There were no statistically significant differences in lesion depth between the five-second argon laser and the visible light control groups. Overall, there was a 15% and 22% reduction in lesion depths for the five- and 10-second group, respectively. Poor correlations were found between the clinical appearance of decalcifications and their lesion depth. Argon lasers used for bonding orthodontic brackets would save a significant amount of chair time while possibly conferring demineralization resistance upon the enamel. PMID:12828433

  8. The investigation of argon diffusion in phlogopite under high pressure conditions

    Science.gov (United States)

    Yudin, Denis; Korzhova, Sophia; Travin, Alexey; Zhimulev, Egor; Murzintsev, Nikolay; Moroz, Tatiana

    2014-05-01

    The present study deals with assessment of pressure effect on the mechanism of bleeding an argon from mica at high temperatures and pressures. The influence of pressure on the diffusion of argon in crustal conditions is not significant (Harrison et al., 2009), while in the mantle conditions, should be significant. The authors suggest that the findings will help to better understand the behavior of K/Ar isotopic system in mica under the lower crust and mantle, including xenoliths transport by kimberlite melt. The experiment was made by using high-pressure spacer "split-sphere" (BARS - 300). Phlogopite from veins cutting metamorphic rocks from the Sludyanka number 2 quarry was used as a testing material. Inclusions of other minerals were not found in the original phlogopite crystal. Chemical composition of phlogopite is homogeneous. 8 experiments was made at a constant pressure of 30 kbar and different temperature and duration: 20 degrees Celsius, 20 minutes; 700 degrees Celsius, 20 minutes; 800 degrees Celsius, 10 minutes; 800 degrees Celsius, 20 minutes; 800 degrees Celsius, 30 minutes; 900 degrees Celsius, 20 minutes; 1000 degrees Celsius, 20 minutes; 1100 degrees Celsius, 20 minutes. According the results of SEM-observation, there is no signs of recrystallization and solid state transformations and melting of phlogopite. It's chemical composition is identical to that of the original phlogopite. Diffractograms of phlogopites after the experiments are similar to the diffractograms of the original phlogopites. Research results of IR spectroscopy, together with the results of SEM and microprobe analysis suggest that phlogopite dehydroxylation in the temperature range T = 700-900 degrees Celsius was negligible. Numerical simulation of the behavior of radiogenic argon in phlogopite at high temperatures and pressure was performed using «Diffarg» software finite differences algorithm, based on the mechanism of bulk thermally activated diffusion (Wheeler, 1996). The

  9. The influence of C2H2 and dust formation on the time dependence of metastable argon density in pulsed plasmas

    OpenAIRE

    Stefanovic, Ilija; Sadeghi, Nader; Winter, Jörg

    2010-01-01

    Abstract Diode laser absorption at 772.38 nm is used to measure the time resolved density of Ar*(3 P 2) metastable atoms in a capacitively coupled radio-frequency (RF) discharge running in argon/acetylene mixture at 0.1 mbar. The RF power is pulsed at 100 Hz and the density of Ar*(3 P 2) atoms in the 5 ms ON time and in the afterglow are recorded. Different plasma conditions, namely: 1) pure argon, 2) argon + 7% acetylene before powder formation, 3) argon + 7% acetylene after dust particle...

  10. Development of large area nanostructured silicon-hydrogen alloy material with improved stability for solar cell application by argon dilution method

    Science.gov (United States)

    Dey, Arka; Das, Mrinmay; Datta, Joydeep; Jana, Rajkumar; Dhar, Joydeep; Sil, Sayantan; Biswas, Debasish; Banerjee, Chandan; Ray, Partha Pratim

    2016-07-01

    Here we have presented the results of large area (30 × 30 cm2) silicon-hydrogen alloy material and solar cell by argon dilution method. As an alternative to hydrogen dilution, argon dilution method has been applied to develop single junction solar cell with appreciable stability. Optimization of deposition conditions revealed that 95% argon dilution gives a nanostructured material with improved transport property and less light induced degradation. The minority carrier diffusion length (L d ) and mobility-lifetime (μτ) product of the material with 95% argon dilution degrades least after light soaking. Also the density of states (DOS) below conduction level reveals that this material is less defective. Solar cell with this argon diluted material has been fabricated with all the layers deposited by argon dilution method. Finally we have compared the argon diluted solar cell results with the optimized hydrogen diluted solar cell. Light soaking study proves that it is possible to develop stable solar cell on large area by argon dilution method and that the degradation of argon diluted solar cell is less than that of hydrogen diluted one. [Figure not available: see fulltext.

  11. The Trigger Readout Electronics for the Phase-I Upgrade of the ATLAS Liquid Argon Calorimeters

    CERN Document Server

    Xu, Hao; The ATLAS collaboration

    2016-01-01

    For the Phase-I luminosity upgrade of the LHC a higher granularity trigger readout of the ATLAS Liquid Argon (LAr) Calorimeters is foreseen to enhance the trigger feature extraction and background rejection. The new readout system digitizes the detector signals, grouped into 34000 so-called Super Cells, with 12bit precision at 40MHz and transfers the data on optical links to the digital processing system, which computes the Super Cell transverse energies. In this paper, development and test results of the new readout system are presented.

  12. Atomic and ionic spectrum lines below 2000A: hydrogen through argon

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, R.L.

    1982-10-01

    A critical tabulation of observed spectral lines below 2000 angstroms has been prepared from the published literature up to July 1978. It is intended principally as an aid to those physicists and astronomers who deal with the spectra of highly stripped atoms. This report includes the first 18 elements, from hydrogen (including deuterium) through argon. The tabulation is divided into two main sections: the spectrum lines by spectrum, and a finding list. The entries for each element give the ionization species, ground state term, and ionization potential, as well as the best values of vacuum wavelength, intensity, and classification. A list of the pertinent references is appended at the end.

  13. Enhanced resolution in Argon and Neon spectra using a Super-Resolution algorithm

    CERN Document Server

    Hoyos-Campo, L M; Capella, A

    2016-01-01

    This paper presents the principles and application of a super-resolution (SR) technique aimed to obtain high resolution spectra obtained from the optogalvanic effect in Neon and Argon discharges over the 413-423 nm wavelength range. By applying the super-resolution algorithm to the experimental data, a surprising 70-fold reduction of the linewidth is achieved allowing to resolve prior indistinguishable peaks. In addition to this, the limits on the applicability of this powerful mathematical technique, mainly the signal to noise ratio of the original spectra, as well as the potential applications of the SR algorithm in other spectroscopic applications are discussed upon.

  14. Surface modification of ultra-high molecular weight polyethylene (UHMWPE) by argon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Liu Hengjun; Pei Yanan [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Xie Dong [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); School of Physical Science and Technology, Southwest Jiaotong University, Chengdu 610031 (China); Deng Xingrui [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Leng, Y.X., E-mail: yxleng@263.net [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Jin Yong, E-mail: jyct@163.com [Interventional Therapy Department, The Second Affiliated Hospital, Soochow University, Suzhou 215004 (China); Huang Nan [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China)

    2010-04-01

    In this work, argon (Ar) plasma generated by microwave electron cyclotron resonance (MWECR) has been used to modify the UHMWPE in order to increase the wear resistance. The results showed that the wettability, anti-scratch and wear resistance of UHMWPE treated by the Ar plasma had been improved, comparing with native UHMWPE. The FTIR and XPS spectra indicated the improvement of wettability should come from the oxygen based functional groups generated on the surface of UHMWPE. The improvement of anti-scratch and wear resistance may come from the enhancement of crosslinking of UHMWPE by Ar plasma treatment.

  15. Emission Spectroscopy of OH Radical in Water-Argon Arc Plasma Jet

    OpenAIRE

    Alan Mašláni; Viktor Sember

    2014-01-01

    Emission spectra of OH radical are studied in the plasma jet generated by a plasma torch with hybrid water-argon stabilization. Plasma jet is located in a chamber with pressures 4 kPa and 10 kPa. In spite of high temperatures of produced plasma, OH spectra are observed in a large area of the jet. OH spectra are used to obtain rotational temperatures from the Boltzmann plots of resolved rotational lines. Due to line-of-sight integration of radiation, interpretation of the temperatures is not s...

  16. Argon 4s and 4p Excited States Atomic Data Applied in ARC-JET Modeling

    Directory of Open Access Journals (Sweden)

    K. Katsonis

    2011-01-01

    Full Text Available Evaluated atomic data concerning the 4s and 4p configurations of Ar I are averaged in order to simplify their use in various cases of Ar plasma modeling and diagnostics. These data are used here to model a low-power arcjet, running with Argon at low pressure. In so doing, they are explicitly introduced in the chemical processes included in a fluid Navier-Stokes type code, allowing for evaluation of the spectroscopically measurable level populations and of the electronic temperatures. The characteristics of the model are described and the main processes are discussed in view of the results of the calculations.

  17. WA105: a large-scale demonstrator of the Liquid Argon double phase TPC

    Science.gov (United States)

    Tonazzo, A.; WA105 Collaboration

    2016-05-01

    The physics case for a large underground detector devoted to neutrino oscillation measurements, nucleon decay and astrophysics is compelling. A time projection chamber based on the dual-phase liquid Argon technique is an extremely attractive option, allowing for long drift distances, low energy threshold and high readout granularity. It has been extensively studied in the LAGUNA-LBNO Design Study and is one of the two designs foreseen for the modules of the DUNE detector in the US. The WA105 experiment envisages the construction of a large scale prototype at CERN, to validate technical solutions and perform physics studies with charged particle beams.

  18. Differential cross sections for the electron-impact near-threshold electronic excitation of argon

    Energy Technology Data Exchange (ETDEWEB)

    Mondal, S; Lower, J; Buckman, S; McEachran, R P [Centre for Antimatter-Matter Studies, Australian National University, Canberra ACT 0200 (Australia); Garcia, G, E-mail: Suhendu.mondal@anu.edu.a [Instituto de Fisica Fundamental, CSIC, Serrano 113-bis, 28006, Madrid (Germany)

    2009-11-01

    Absolute accurate differential cross section data are presented for the excitation of the 3p{sup 5}4s state in argon by electron impact. The study focuses on the near-threshold region, where previous studies have revealed persistent disparities between measurement and theory. The time-of-flight (TOF) technique is employed, allowing scattered electrons to be measured over a broad range of energies with constant transmission, thereby eliminating a potential source of error in relating relative intensities of elastic and inelastic transitions inherent to other techniques. The experimental results are compared to new relativistic distorted-wave (RDW) calculations as well as to previous experimental and theoretical studies.

  19. Possibilities of removing lead from industrial Cu-Pb-Fe alloy with of argon barbortage

    OpenAIRE

    B. Oleksiak

    2009-01-01

    In this article results of research on removal of the lead from industrial Cu-Pb-Fe alloy by means of argon barbotage are presented. The examinations was performed on an industrial alloy from the “Glogow II” Copperworks. As a basic research equipment a pipe resistance furnace enabling heating of a sample up to 1773 K temperature was used. All researches were conducted at 1473 K, 1523 K, 1573 K temperature and with gas flow 5,55×10-6, 6,94×10-6, 8,33×10-6, 9,72×10-6 m3/s.

  20. Removal of lead from the industrial and synthetic Cu-Pb-Fe alloy with argon barbotage

    OpenAIRE

    B. Oleksiak; G. Siwiec

    2012-01-01

    Results of research on removal of lead from synthetic and industrial Cu-Pb-Fe alloy with argon barbotage are presented. For examinations was taken a synthetic alloy and industrial alloy coming “Glogow II” Copperworks. As basic research equipment was used a pipe resistance furnace enabling heating of samples up to 1 473 K. Examinations were made in 2 test series. The 1 series was performed on the synthetic alloy, while in 2 series was used an industrial alloy. All series were conducted at 1 47...

  1. A CMOS current preamplifier and shaper with 50Ω line driver for liquid argon preshower

    International Nuclear Information System (INIS)

    In the field of liquid argon calorimetry for the LHC detector program, a CMOS ''current conveyor'' preamplifier was cold preshower. It is an improved version of the ICON circuit which had been formerly designed by the RD2 collaboration. This paper also presents a CMOS linear output buffer, featuring a dynamic range close to ±2V on a 50Ω load, for a 21 mW power dissipation at 77K. Furthermore a biquadratic 7 MHz bandpass filter was developed, based on a high speed rail to rail CMOS operational amplifier. It is meant to be the filter placed at the output of the ICON preamplifier

  2. A New Type of Porous Plug for Blowing Argon in the VHD

    Institute of Scientific and Technical Information of China (English)

    XUShi-zheng; YANGYong; 等

    1995-01-01

    In the process of VHD,argon is blown into the molten steel throuht the porous plugs which are mounted in the ladle bottom.A new type of porous corundum plug has been developed for the VHD secondary refining ladle furnace in Fushun Steel Works ,It is found that when the mean grain size of corundum articles decreases from 760 μm tp 650μm ,the physical properties and service life of the plug are the same as that of importedone ,and can be normally used in the VHD process.

  3. Extreme ultraviolet spectroscopy of highly charged argon ions at the Berlin EBIT

    Energy Technology Data Exchange (ETDEWEB)

    Biedermann, C; Radtke, R; Fussmann, G; Allen, F I [Institut fuer Physik der Humboldt-Universitaet zu Berlin, Lehrstuhl Plasmaphysik, Newtonstrass 15, 12489 Berlin and Max-Planck-Institut fuer Plasmaphysik, EURATOM Association (Germany)

    2007-06-15

    Extreme ultraviolet radiation from highly charged argon was investigated at the Berlin Electron Beam Ion Trap with a 2 m grazing incidence spectrometer. Lines in the wavelength range 150 to 660 A originating from C-like Ar{sup 12+}to Li-like Ar{sup 15+}ions have been identified and are compared with database information from solar line lists and predictions. Line ratios for the observed resonance, intercombination and forbidden lines offer important diagnostic capabilities for low density, hot plasmas.

  4. High enthalpy, hypervelocity flows of air and argon in an expansion tube

    Science.gov (United States)

    Neely, A. J; Stalker, R. J.; Paull, A.

    1991-01-01

    An expansion tube with a free piston driver has been used to generate quasi-steady hypersonic flows in argon and air at flow velocities in excess of 9 km/s. Irregular test flow unsteadiness has limited the performance of previous expansion tubes, and it has been found that this can be avoided by attention to the interaction between the test gas accelerating expansion and the contact surface in the primary shock tube. Test section measurements of pitot pressure, static pressure and flat plate heat transfer are reported. An approximate analytical theory has been developed for predicting the velocities achieved in the unsteady expansion of the ionizing or dissociating test gas.

  5. Surface modification of ultra-high molecular weight polyethylene (UHMWPE) by argon plasma

    International Nuclear Information System (INIS)

    In this work, argon (Ar) plasma generated by microwave electron cyclotron resonance (MWECR) has been used to modify the UHMWPE in order to increase the wear resistance. The results showed that the wettability, anti-scratch and wear resistance of UHMWPE treated by the Ar plasma had been improved, comparing with native UHMWPE. The FTIR and XPS spectra indicated the improvement of wettability should come from the oxygen based functional groups generated on the surface of UHMWPE. The improvement of anti-scratch and wear resistance may come from the enhancement of crosslinking of UHMWPE by Ar plasma treatment.

  6. Ionization of Water Clusters is Mediated by Exciton Energy Transfer from Argon Clusters

    Energy Technology Data Exchange (ETDEWEB)

    Golan, Amir; Ahmed, Musahid

    2012-01-25

    The exciton energy deposited in an argon cluster, (Arn ,< n=20>) using VUV radiation is transferred to softly ionize doped water clusters, ((H2O)n, n=1-9) leading to the formation of non-fragmented clusters. Following the initial excitation, electronic energy is channeled to ionize the doped water cluster while evaporating the Ar shell, allowing identification of fragmented and complete water cluster ions. Examination of the photoionization efficiency curve shows that cluster evaporation from excitons located above 12.6 eV are not enough to cool the energized water cluster ion, and leads to their dissociation to (H2O)n-2H+ (protonated) clusters.

  7. Low-energy structure in the ionization of argon:Comparison of experiment with theory

    Institute of Scientific and Technical Information of China (English)

    Feng Li-Qiang; Chu Tian-Shu; Wang Li

    2013-01-01

    The above-threshold ionization of argon in an intense 70-fs,400-nm linearly polarized laser pulse has been investigated by the velocity map imaging techniques,combined with an attosecond-resolution quantum wave packet dynamics method.There is a quantitative agreement in all dominant features between the experiment and the theory.Moreover,a peak-splitting phenomenon in the first energy peak has been observed at high pulse intensity.Further,through the theoretical analysis,an ac Stark splitting with evident resonant and nonresonant ionization pathways has been found to be the physical reason for the experimental observations.

  8. Electron Temperature Control in Inductively Coupled Nitrogen Plasmas by Adding Argon/Helium

    Institute of Scientific and Technical Information of China (English)

    康正德; 蒲以康

    2002-01-01

    A new technique, adding argon or helium into nitrogen plasma, has been used to regulate the electron temperature in an inductively coupled plasma. The electron temperature is determined by analysing the intensity ratio of two nitrogen spectrum lines. The results show that, when the total pressure is 0.7Pa, the electron temperature increases with the increase of the He partial pressure in He/N2 plasma, but the electron temperature decreases with the increase of the Ar partial pressure in Ar/N2 plasma. The regulation effect of electron temperature is weaker in higher pressure N2/He plasma of 2.6Pa.

  9. Radiation hard micro-coaxial cables for the ATLAS liquid argon calorimeters

    CERN Document Server

    Bonivento, W; Imbert, P; de La Taille, C

    2000-01-01

    The ATLAS collaboration has chosen for the electromagnetic barrel calorimeter and for all the end-cap calorimeters a sampling technique, with liquid argon as the active medium. The read-out electronics and the calibration pulsers are located in boxes outside the cryostats housing the detectors. Signals are transmitted between the detectors and the electronic boxes through custom-designed micro- coaxial cables, which are the subject of this paper. These cables have to satisfy very stringent tolerances in terms of signal transmission, dimensions and radiation hardness. Following a successful pre-series production, these cables have been selected for equipping the ATLAS calorimeter. (16 refs).

  10. High precision wavelength measurements of QED-sensitive forbidden transitions in highly charged argon ions.

    Science.gov (United States)

    Draganić, I; Crespo López-Urrutia, J R; DuBois, R; Fritzsche, S; Shabaev, V M; Orts, R Soria; Tupitsyn, I I; Zou, Y; Ullrich, J

    2003-10-31

    We present the results of an experimental study of magnetic dipole (M1) transitions in highly charged argon ions (Ar X, Ar XI, Ar XIV, Ar XV) in the visible spectral range using an electron beam ion trap. Their wavelengths were determined with, for highly charged ions, unprecedented accuracy up to the sub-ppm level and compared with theoretical calculations. The QED contributions, calculated in this Letter, are found to be 4 orders of magnitude larger than the experimental error and are absolutely indispensable to bring theory and experiment to a good agreement. This method shows great potential for the study of QED effects in relativistic few-electron systems.

  11. Nitrogen/argon diluted acetylene and ethylene blue flames under infrared CO2 laser irradiation

    OpenAIRE

    Pikhitsa, Peter V.; Daegyu Kim; Mansoo Choi

    2011-01-01

    We investigated changes in emission spectra from nitrogen/argon diluted laminar diffusion acetylene and ethylene blue flames irradiated by a powerful cw infrared CO2 laser. The changes in the radical emission bands can be interpreted as an indication of laser-induced decomposition of ethylene (for laser absorbing C2H4 fuel) and of laser-absorbing intermediates (for non-absorbing C2H2 fuel). The results indicate that released active hydrogen plays an important role in addition/abstraction reac...

  12. Development of ATLAS Liquid Argon Calorimeter Read-out Electronics for the HL-LHC

    CERN Document Server

    Newcomer, Mitchel; The ATLAS collaboration

    2015-01-01

    The high-luminosity phase of the Large Hadron Collider will provide a 5-7 times greater instantaneous and total luminosities than assumed in the original design of the ATLAS Liquid Argon Calorimeters and their read-out system. An improved trigger system with higher acceptance rate and longer latency and a better radiation tolerance require an upgrade of the read-out electronics. Concepts for the future read-out of the 183.000 calorimeter channels at 40-80 MHz and 16 bit dynamic range, and the development of radiation tolerant, low noise, low power and high-bandwidth electronic components will be presented.

  13. The Effect of the Argon Carrier Gas in the Multiphoton Dissociation-Ionization of Tetracene

    OpenAIRE

    Carmen Cisneros; Ignacio ÃÂlvarez; Alfonso Guerrero; Alejandro San Román; Juan Carlos Poveda

    2008-01-01

    The multiphoton dissociation-ionization of tetracene at 355 nm using 6.5 nanosecond laser pulses, with and without argon as a carrier gas (CG), has been studied and compared. Ion fragments were analyzed in a time-of-flight mass spectrometer and separated according to their mass-to-charge ratio (m/z). The results show that the dynamic of photodissociation at ~1010 W⋅cm-2 intensities is strongly influenced by the CG. The suppression of fragmentation channels primarily those relating to the...

  14. A cryogenic monitor system for the Liquid Argon Calorimeter in the SLD detector

    Energy Technology Data Exchange (ETDEWEB)

    Fox, M.J.; Fox, J.D.

    1988-10-01

    This paper describes the monitoring electronics system design for the Liquid Argon Calorimeter (LAC) portion of the SLD detector. This system measures temperatures and liquid levels inside the LAC cryostat and transfers the results over a fiber-optic serial link to an external monitoring computer. System requirements, unique design constraints, and detailed analog, digital and software designs are presented. Fault tolerance and the requirement for a single design to work in several different operating environments are discussed. 4 refs., 3 figs., 1 tab.

  15. A cryogenic monitor system for the Liquid Argon Calorimeter in the SLD detector

    International Nuclear Information System (INIS)

    This paper describes the monitoring electronics system design for the Liquid Argon Calorimeter (LAC) portion of the SLD detector. This system measures temperatures and liquid levels inside the LAC cryostat and transfers the results over a fiber-optic serial link to an external monitoring computer. System requirements, unique design constraints, and detailed analog, digital and software designs are presented. Fault tolerance and the requirement for a single design to work in several different operating environments are discussed. 4 refs., 3 figs., 1 tab

  16. Nitrogen/argon diluted acetylene and ethylene blue flames under infrared CO2 laser irradiation

    Directory of Open Access Journals (Sweden)

    Peter V. Pikhitsa

    2011-09-01

    Full Text Available We investigated changes in emission spectra from nitrogen/argon diluted laminar diffusion acetylene and ethylene blue flames irradiated by a powerful cw infrared CO2 laser. The changes in the radical emission bands can be interpreted as an indication of laser-induced decomposition of ethylene (for laser absorbing C2H4 fuel and of laser-absorbing intermediates (for non-absorbing C2H2 fuel. The results indicate that released active hydrogen plays an important role in addition/abstraction reactions without any participation of oxygen.

  17. Effect of neutral gas heating in argon radio frequency inductively coupled plasma

    International Nuclear Information System (INIS)

    Heating of neutral gas in inductively coupled plasma (ICP) is known to result in neutral gas depletion. In this work, this effect is considered in the simulation of the magnetic field distribution of a 13.56 MHz planar coil ICP. Measured electron temperatures and densities at argon pressures of 0.03, 0.07 and 0.2 mbar were used in the simulation whilst neutral gas temperatures were heuristically fitted. The simulated results showed reasonable agreement with the measured magnetic field profile. (author)

  18. Preparation of a primary argon beam for the CERN fixed target physics.

    Science.gov (United States)

    Küchler, D; O'Neil, M; Scrivens, R; Thomae, R

    2014-02-01

    The fixed target experiment NA61 in the North Area of the Super Proton Synchrotron is studying phase transitions in strongly interacting matter. Up to now they used the primary beams available from the CERN accelerator complex (protons and lead ions) or fragmented beams created from the primary lead ion beam. To explore a wider range of energies and densities a request was made to provide primary argon and xenon beams. This paper describes the results of the setting up and 10 week test run of the Ar(11+) beam from the 14.5 GHz ECR ion source and the linear accelerator (Linac3) at CERN.

  19. Nuclear recoil correction to the g factor of boron-like argon

    CERN Document Server

    Shchepetnov, Arseniy A; Volotka, Andrey V; Shabaev, Vladimir M; Tupitsyn, Ilya I; Plunien, Guenter

    2014-01-01

    The nuclear recoil effect to the g factor of boron-like ions is investigated. The one-photon-exchange correction to the nuclear recoil effect is calculated in the non-relativistic approximation for the nuclear recoil operator and in the Breit approximation for the interelectronic-interaction operator. The screening potential is employed to estimate the higher-order contributions. The updated g-factor values are presented for the ground 2P_1/2 and first excited 2P_3/2 states of B-like argon 40^Ar^13+, which are presently being measured by the ARTEMIS group at GSI.

  20. Two-photon excitation/ionization of the 1s-shell of the argon atom

    CERN Document Server

    Novikov, S A

    2002-01-01

    The absolute values and the shape of the two-photon excitation/ionization cross section of the 1s-shell of the argon atom are calculated with inclusion of the many-particle effects, i.e., the relaxation of the atomic residue in the field of the vacancies created, and the decay of the vacancies into the channels of Auger and (or) radiative types. The wavefunctions of the one-particle states are calculated in non-relativistic approximation. The calculations are performed for both linear and circular polarization of the laser beam.

  1. Two-photon excitation/ionization of the 1s-shell of the argon atom

    International Nuclear Information System (INIS)

    The absolute values and the shape of the two-photon excitation/ionization cross section of the 1s-shell of the argon atom are calculated with inclusion of the many-particle effects, i.e., the relaxation of the atomic residue in the field of the vacancies created, and the decay of the vacancies into the channels of Auger and (or) radiative types. The wavefunctions of the one-particle states are calculated in non-relativistic approximation. The calculations are performed for both linear and circular polarization of the laser beam.

  2. Ionization of Argon n=2 (Ar+9 to Ar+16) by a 'relativistic' laser field

    International Nuclear Information System (INIS)

    The high field photoionization cross sections for the (n=2) shell of argon were measured with pulsed 800 nm radiation (27±5 fs duration) at an intensity of 1.5x1019 W/cm2±1x1019 W/cm2. The pondermotive energy for an electron at these field intensities is approximately 1 MeV. The best agreement with a calculated AC tunneling model was at an intensity of 0.6x1019 W/cm2. The difference between experimental and calculated relative charge state yields is less than an order of magnitude for Ar+9 to Ar+14 and Ar+16

  3. Observation of the fcc-to-hcp transition in ensembles of argon nanoclusters.

    Science.gov (United States)

    Krainyukova, N V; Boltnev, R E; Bernard, E P; Khmelenko, V V; Lee, D M; Kiryukhin, V

    2012-12-14

    Macroscopic ensembles of weakly interacting argon nanoclusters are studied using x-ray diffraction in low vacuum. As the clusters grow by fusion with increasing temperature, their structure transforms from essentially face-centered cubic (fcc) to hexagonal close packed as the cluster size approaches ~10(5) atoms. The transformation involves intermediate orthorhombic phases. These data confirm extant theoretical predictions. They also indicate that growth kinetics and spatial constraints might play an important role in the formation of the fcc structure of bulk rare-gas solids, which still remains puzzling.

  4. R&D Argon Detector at Ash River (RADAR) - Letter of Intent

    CERN Document Server

    Adamson, P; Guzowski, P; Habig, A; Holin, A; Huang, J; Kordosky, M; Kreymer, A E; Lang, K; Marshak, M; Mehdiyev, R; Miller, W H; Naples, D; Nichol, R J; Patterson, R B; Sousa, A; Thomas, J; Whitehead, L H

    2013-01-01

    The RADAR project proposes to deploy a 6 kton liquid argon TPC at the NOvA Far Detector building in Ash River, Minnesota, and expose it to the NuMI beam during NOvA running. It will significantly add to the physics capabilities of the NOvA program while providing LBNE with an R&D program based on full-scale TPC module assemblies. RADAR offers an excellent opportunity to improve the full Homestake LBNE project in physics reach, timeline, costs, and fostering international partnership. The anticipated duration of the project's construction is 5 years, with running happening between 2018 and 2023.

  5. Calculation of the thermodynamic parameters and the degree of ionization of argon at sonoluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Borisenok, V. A., E-mail: vaborisenok@mephi.ru; Medvedev, A. B. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Sarov Physical-Technical Institute (Russian Federation)

    2015-12-15

    The results of the numerical simulation of the behavior of a system consisting a spherical bubble filled with gaseous argon and surrounded by water under the impact of an external periodic pressure are presented. It is shown that, under typical conditions for the experimental investigation of single-bubble sonoluminescence in such a system, conditions are created for its thermal ionization near the time instant of the maximum compression in the gas. This proves one of the main provisions of the polarization model of sonoluminescence.

  6. LArGe: active background suppression using argon scintillation for the Gerda 0ν β β -experiment

    Science.gov (United States)

    Agostini, M.; Barnabé-Heider, M.; Budjáš, D.; Cattadori, C.; Gangapshev, A.; Gusev, K.; Heisel, M.; Junker, M.; Klimenko, A.; Lubashevskiy, A.; Pelczar, K.; Schönert, S.; Smolnikov, A.; Zuzel, G.

    2015-10-01

    LArGe is a Gerda low-background test facility to study novel background suppression methods in a low-background environment, for future application in the Gerda experiment. Similar to Gerda, LArGe operates bare germanium detectors submersed into liquid argon (1 m^3, 1.4 tons), which in addition is instrumented with photomultipliers to detect argon scintillation light. The scintillation signals are used in anti-coincidence with the germanium detectors to effectively suppress background events that deposit energy in the liquid argon. The background suppression efficiency was studied in combination with a pulse shape discrimination (PSD) technique using a BEGe detector for various sources, which represent characteristic backgrounds to Gerda. Suppression factors of a few times 10^3 have been achieved. First background data of LArGe with a coaxial HPGe detector (without PSD) yield a background index of (0.12-4.6)× 10^{-2} cts/(keV kg year) (90 % C.L.), which is at the level of Gerda Phase I. Furthermore, for the first time we monitor the natural ^{42}Ar abundance (parallel to Gerda), and have indication for the 2ν β β -decay in natural germanium. These results show the effectivity of an active liquid argon veto in an ultra-low background environment. As a consequence, the implementation of a liquid argon veto in Gerda Phase II is pursued.

  7. LArGe: active background suppression using argon scintillation for the GERDA 0νββ-experiment

    International Nuclear Information System (INIS)

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for future application in the GERDA experiment. Similar to GERDA, LArGe operates bare germanium detectors submersed into liquid argon (1 m3, 1.4tons), which in addition is instrumented with photomultipliers to detect argon scintillation light. The scintillation signals are used in anti-coincidence with the germanium detectors to effectively suppress background events that deposit energy in the liquid argon. The background suppression efficiency was studied in combination with a pulse shape discrimination (PSD) technique using a BEGe detector for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 103 have been achieved. First background data of LArGe with a coaxial HPGe detector (without PSD) yield a background index of (0.12 - 4.6) x 10-2 cts/(keV kg year) (90 % C.L.), which is at the level of GERDA Phase I. Furthermore, for the first time we monitor the natural 42Ar abundance (parallel to GERDA), and have indication for the 2νββ-decay in natural germanium. These results show the effectivity of an active liquid argon veto in an ultra-low background environment. As a consequence, the implementation of a liquid argon veto in GERDA Phase II is pursued. (orig.)

  8. Effects of argon ion irradiation on nucleation and growth of silver nanoparticles in a soda-glass matrix

    Directory of Open Access Journals (Sweden)

    P. Gangopadhyay

    2011-09-01

    Full Text Available The present article explores an experimental study for nucleation and non-equilibrium growth of silver nanoparticles in a soda-glass matrix. Ion-irradiation induced recoiling of silver atoms with argon ions (at energy 100 keV facilitates nucleation as well as growth of the silver nanoparticles in the soda-glass matrix. Small growth of the silver nanoparticles in the soda-glass matrix has been experimentally observed after the irradiation with higher fluences of the argon ions. Role of the argon ions for the evolution of the silver nanoparticles in the soda-glass matrix has been elucidated in the present report. With increase of the argon-ion fluences, while slight athermal growth of the silver nanoparticles has been estimated, drastic increase in the optical responses and Rutherford backscattering (RBS yields of the silver nanoparticles have been observed in the sample with the maximum fluences. Possible correlations of increase of argon-ion fluences and the observed experimental results (optical and RBS, in particular have been explained in this article. Although it has been demonstrated using the silver metal film on a soda-glass substrate as a model example, the non-equilibrium approach of nucleation and ion-beam controlled growth of metal nanoparticles in a matrix should be applicable to other immiscible systems as well.

  9. Effects of metastable species in helium and argon atmospheric pressure plasma jets (APPJs) on inactivation of periodontopathogenic bacteria

    Science.gov (United States)

    Yoon, Sung-Young; Kim, Kyoung-Hwa; Seol, Yang-Jo; Kim, Su-Jeong; Bae, Byeongjun; Huh, Sung-Ryul; Kim, Gon-Ho

    2016-05-01

    The helium and argon have been widely used as discharge gases in atmospheric pressure plasma jets (APPJs) for bacteria inactivation. The APPJs show apparent different in bullet propagation speed and bacteria inactivation rate apparently vary with discharge gas species. This work shows that these two distinctive features of APPJs can be linked through one factor, the metastable energy level. The effects of helium and argon metastable species on APPJ discharge mechanism for reactive oxygen nitrogen species (RONS) generation in APPJs are investigated by experiments and numerical estimation. The discharge mechanism is investigated by using the bullet velocity from the electric field which is obtained with laser induced fluorescence (LIF) measurement. The measured electric field also applied on the estimation of RONS generation, as electron energy source term in numerical particle reaction. The estimated RONS number is verified by comparing NO and OH densities to the inactivation rate of periodontitis bacteria. The characteristic time for bacteria inactivation of the helium-APPJ was found to be 1.63 min., which is significantly less than that of the argon-APPJ, 12.1 min. In argon-APPJ, the argon metastable preserve the energy due to the lack of the Penning ionization. Thus the surface temperature increase is significantly higher than helium-APPJ case. It implies that the metastable energy plays important role in both of APPJ bullet propagation and bacteria inactivation mechanism.

  10. LArGe: active background suppression using argon scintillation for the GERDA 0νββ-experiment

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, M.; Budjas, D.; Schoenert, S. [Technische Universitaet Muenchen, Munich (Germany); Barnabe-Heider, M. [Technische Universitaet Muenchen, Munich (Germany); Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Cattadori, C. [Universita degli Studi di Milano, Milan (Italy); INFN, Milan (Italy); Gangapshev, A. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Institut for Nuclear Research, Moscow (Russian Federation); Gusev, K. [Technische Universitaet Muenchen, Munich (Germany); Joint Institut for Nuclear Research, Dubna (Russian Federation); National Research Center Kurchatov Institut, Moscow (Russian Federation); Heisel, M.; Smolnikov, A. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Junker, M. [Laboratori Nazionali del Gran Sasso, Assergi (Italy); Klimenko, A.; Lubashevskiy, A. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Joint Institut for Nuclear Research, Dubna (Russian Federation); Pelczar, K. [Jagellonian University, Cracow (Poland); Zuzel, G. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Jagellonian University, Cracow (Poland)

    2015-10-15

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for future application in the GERDA experiment. Similar to GERDA, LArGe operates bare germanium detectors submersed into liquid argon (1 m{sup 3}, 1.4tons), which in addition is instrumented with photomultipliers to detect argon scintillation light. The scintillation signals are used in anti-coincidence with the germanium detectors to effectively suppress background events that deposit energy in the liquid argon. The background suppression efficiency was studied in combination with a pulse shape discrimination (PSD) technique using a BEGe detector for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe with a coaxial HPGe detector (without PSD) yield a background index of (0.12 - 4.6) x 10{sup -2} cts/(keV kg year) (90 % C.L.), which is at the level of GERDA Phase I. Furthermore, for the first time we monitor the natural {sup 42}Ar abundance (parallel to GERDA), and have indication for the 2νββ-decay in natural germanium. These results show the effectivity of an active liquid argon veto in an ultra-low background environment. As a consequence, the implementation of a liquid argon veto in GERDA Phase II is pursued. (orig.)

  11. Theoretical investigation of the effect of hydrogen addition on the formation and properties of soliton in direct current argon plasma

    International Nuclear Information System (INIS)

    In this study the effect of hydrogen addition on the formation and properties of soliton in direct-current (DC) argon plasma is theoretically investigated. By coupling fluid equations with Poisons equation for such multi-component plasma, the Mach number and amplitude of the soliton are determined following pseudo potential method. Addition of hydrogen in argon discharge leads to the decrease of electron, Ar+ ion density while a reverse trend was observed for ArH+ and hydrogen like ions. It was found that presence of hydrogen like ions in argon plasma affects the formation of soliton with its amplitude significantly decreases as concentration of hydrogen increases. On the other hand, increase in ion to electron temperature ratios of the lighter ions in the discharge also has a significant influence on the amplitude and formation of soliton. The inverse relation between solitons width and amplitude is found to be consistent for the entire range of study

  12. Pulsed microwave-driven argon plasma jet with distinctive plume patterns resonantly excited by surface plasmon polaritons

    Institute of Scientific and Technical Information of China (English)

    陈兆权; 殷志祥; 夏广庆; 洪伶俐; 胡业林; 刘明海; 胡希伟

    2015-01-01

    Atmospheric lower-power pulsed microwave argon cold plasma jets are obtained by using coaxial transmission line resonators in ambient air. The plasma jet plumes are generated at the end of a metal wire placed in the middle of the dielec-tric tubes. The electromagnetic model analyses and simulation results suggest that the discharges are excited resonantly by the enhanced electric field of surface plasmon polaritons. Moreover, for conquering the defect of atmospheric argon filamentation discharges excited by 2.45-GHz continued microwave, the distinctive patterns of the plasma jet plumes can be maintained by applying different gas flow rates of argon gas, frequencies of pulsed modulator, duty cycles of pulsed microwave, peak values of input microwave power, and even by using different materials of dielectric tubes. In addition, the emission spectrum, the plume temperature, and other plasma parameters are measured, which shows that the proposed pulsed microwave plasma jets can be adjusted for plasma biomedical applications.

  13. Effects of swift argon-ion irradiation on the proton-exchanged LiNbO3 crystal

    Institute of Scientific and Technical Information of China (English)

    Huang Qing; Liu Peng; Liu Tao; Guo Sha-Sha; Wang Xue-Lin

    2012-01-01

    A proton-exchanged LiNbO3 crystal was subjected to 70-MeV argon-ion irradiation.The lattice damage was investigated by the Rutherford backscattering and channeling technique.It was found that the lattice disorder induced by the proton exchange process was partially recovered and the proton-exchanged layer was broadened.It indicated that the lithium ions underneath the initial proton-exchanged layer migrated to the surface during the swift argon-ion irradiation and supplemented the lack of lithium ions in the initial proton-exchanged layer.This effect was ascribed to the great electronic energy deposition and relaxation.The swift argon-ion irradiation induced an increase in extraordinary refractive index and formed another waveguide structure beneath the proton-exchanged waveguide.

  14. Irradiation effects of argon ion on a plate-type Raney nickel catalyst

    International Nuclear Information System (INIS)

    The present paper deals with restoration of the catalytic activity of Raney nickel deactivated by heat treatment (1), electrochemical oxidation (2) slow oxidation in water by dissolved oxygen (3) and quick oxidation in air (4). The plate-type Raney nickel catalyst used in this experiment is convenient for this particular ion-bombarding technique. The fine powder catalyst usually used could not be applied to this technique. The catalysts deactivated by the methods (2, 3) were activated by means of radio frequency diode sputtering system. An ordinary nickel plate and Raney nickel catalyst heated at high temperature (method 1) or burned in air (method 4) could not be activated by argon ion bombardment, because of the strong Ni-Ni and Ni-O bonds. The appearance of activity in Raney nickel catalyst generally results from amorphous nickel structure, when aluminum is leached from Ni-Al alloy. Activity restoration of catalyst by argon ion bombardment is satisfactly explained on the basis of the same reason. (author)

  15. The ATLAS Liquid Argon Electromagnetic EndCap Calorimeter Construction and tests

    CERN Document Server

    Rodier, S; Del Peso, J

    2003-01-01

    This thesis has been carried out within the ATLAS collaboration. ATLAS is one of the two multipurpose experiments approved for data taking at the Large Hadron Collider (LHC) at CERN. The main goals of this experiment are, to find the Higgs boson, the missing piece in the otherwise so succesful Standard Model of Particle Physics, and to look for physics beyond the Standard Model up to a scale of 1TeV. For this purpose, electromagnetic (EM) calorimetry play a key role. The ATLAS Collaboration has chosen a Liquid Argon (LAr) option with lead as passive material. The liquid Argon Calorimeter is divided into two main subdetectors, the barrel and the end caps (EC). The design and construction of the LAr EM EC calorimeter is the responsability of the groups at Centre de Physique de Marseille (CPPM) and the Universidad Autonoma de Madrid (UAM)following the guideline developed by the research and development working, group 3 for LHC detectors (RD3). The sharing of responsabilities is such that CPPM provides spacers an...

  16. Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

    Science.gov (United States)

    Amaudruz, P.-A.; Batygov, M.; Beltran, B.; Boudjemline, K.; Boulay, M. G.; Cai, B.; Caldwell, T.; Chen, M.; Chouinard, R.; Cleveland, B. T.; Contreras, D.; Dering, K.; Duncan, F.; Ford, R.; Gagnon, R.; Giuliani, F.; Gold, M.; Golovko, V. V.; Gorel, P.; Graham, K.; Grant, D. R.; Hakobyan, R.; Hallin, A. L.; Harvey, P.; Hearns, C.; Jillings, C. J.; Kuźniak, M.; Lawson, I.; Li, O.; Lidgard, J.; Liimatainen, P.; Lippincott, W. H.; Mathew, R.; McDonald, A. B.; McElroy, T.; McFarlane, K.; McKinsey, D.; Muir, A.; Nantais, C.; Nicolics, K.; Nikkel, J.; Noble, T.; O'Dwyer, E.; Olsen, K. S.; Ouellet, C.; Pasuthip, P.; Pollmann, T.; Rau, W.; Retiere, F.; Ronquest, M.; Skensved, P.; Sonley, T.; Tang, J.; Vázquez-Jáuregui, E.; Veloce, L.; Ward, M.

    2015-03-01

    The DEAP-1 7 kg single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the DEAP-3600 Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination, and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them. The 222 Rn decay rate in the liquid argon was measured to be between 16 and 26 μBq kg-1. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.

  17. Preliminary Experimental Investigation on MHD Power Generation Using Seeded Supersonic Argon Flow as Working Fluid

    Institute of Scientific and Technical Information of China (English)

    LI Yiwen; LI Yinghong; LU Haoyu; ZHU Tao; ZHANG Bailing; CHEN Feng; ZHAO Xiaohu

    2011-01-01

    This paper presents a preliminary experimental investigation on magnetohydrodynamic (MHD) power generation using seeded supersonic argon flow as working fluid.Helium and argon are used as driver and driven gas respectively in a shock tunnel.Equilibrium contact surface operating mode is used to obtain high temperature gas,and the conductivity is obtained by adding seed K2CO3 powder into the driven section.Under the conditions of nozzle inlet total pressure being 0.32 MPa,total temperature 6 504 K,magnetic field density about 0.5 T and nozzle outlet velocity 1 959 m/s,induction voltage and short-circuit current of the segmentation MHD power generation channel are measured,and the experimental results agree with theoretical calculations; the average conductivity is about 20 S/m calculated from characteristics of voltage and current.When load factor is 0.5,the maximum power density of the MHD power generation channel reaches 4.797 1 MW/m3,and the maximum enthalpy extraction rate is 0.34%.Finally,the principle and method of indirect testing for gas state parameters are derived and analyzed.

  18. Installation of the Liquid Argon Calorimater Barrel in the ATLAS Experimental Cavern

    CERN Multimedia

    Vandoni, G.

    On the 27th of October, the Liquid Argon Barrel cryostat was transported from Building 180 to point 1. The next day, the Barrel was lowered into the cavern, and was placed on jacks close to its final position inside the completed lower half of the Tile calorimeter. After a day of precise adjustment, it was resting within a few millimetres of its nominal final position, waiting for the upper half of the Tile calorimeter to be installed. Tight requests had been issued by the Liquid Argon collaboration for the whole transport. It was foreseen that the cryostat should not see any acceleration larger than 0.15g along its axis, 0.08g transversally and 0.3g in the vertical direction. In addition, no acceleration higher than 0.03g (or even 0.003g for permanent oscillation) would be allowed at 20Hz, to avoid the risk of damaging the absorbers at this spontaneous vibration frequency. The difficulty would arise when coping these demands with the tortuous route, its slopes and curbs, vibration transmission from the engi...

  19. Plasma characteristics of argon glow discharge produced by AC power supply operating at low frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Kongpiboolkid, Watcharapon; Mongkolnavin, Rattachat [Department of Physics, Facuty of Science, Chulalongkorn University, Bangkok (Thailand); Plasma Technology and Nuclear Fusion Research Unit, Chulalongkorn University, Bangkok (Thailand)

    2015-04-24

    Non-thermal properties of Argon glow discharge operating with various operating pressures were measured and presented in this work. The Argon plasma is produced by a parallel conducting electrodes coupling with a high voltage AC power supply. The power supply can generate high AC voltage at various frequencies. The frequencies for the operation are in the range of a few kHz. The system is capable of generating electric field between the two metal electrodes discharge system. The characteristics of plasma produced were measured by optical emission spectroscopy (OES) technique where electron temperature (T{sub e}) and electron number density (n{sub e}) can be determined by line intensity ratio method. The value of electron number density was then determined from the Saha-Eggert equation. Our results show that the electron number density of the discharge obtained is of the order of 10{sup −17} − 10{sup −18} m{sup −3} where the electron temperature is between 1.00−2.00 eV for various operating frequencies used which are in good agreement with similar results published earlier.

  20. Status of the Atlas Liquid Argon Calorimeter and its Performance after two years of LHC operation

    CERN Document Server

    AperioBella, L; The ATLAS collaboration

    2012-01-01

    The ATLAS experiment is designed to study the proton-proton collisions produced at the Large Hadron Collider(LHC) at CERN. Liquid argon sampling calorimeters are used for all electromagnetic calorimetry covering the pseudo-rapidity region up to 3.2, as well as for hadronic calorimetry. The most forward part (pseudo-rapidity region 3.1-4.9) contains a electromagnetic section and two hadronic wheels. The electromagnetic calorimeters use lead as passive material and are characterized by an accordion geometry that allows a fast and uniform azimuthal response without any gap. Copper and tungsten were chosen as passive material for the hadronic calorimetry; whereas a classic plate geometry was adopted at large polar angles, an innovative one based on cylindrical electrodes with thin argon gaps was designed for the coverage at low angles, where the particles flow is higher. All detectors are housed in three cryostats kept at 87 K. After installation in 2004-2006, the calorimeters were extensively commissioned over t...

  1. Nitrogen and argon radiopurity investigations for the Borexino and GERDA experiments

    International Nuclear Information System (INIS)

    Borexino will look for low energy solar neutrinos while GERDA is designed to search for neutrinoless double beta decay of 76Ge. Radioactive noble gases of atmospheric origin present as traces in nitrogen or argon can significantly contribute to the background in these experiments. The most important are 39Ar, 85Kr and 222Rn. Nitrogen is used in Borexino for scintillator purification and blanketing, LAr will serve in GERDA as a passive/active shield and as a cooling medium for the Ge crystals. Concentrations of 39Ar, 85Kr and 222Rn in nitrogen must be below 0.5, 0.2 and 7 μBq/m3 (STP), respectively. Rn concentration in the argon used in GERDA should be below 0.5 μBq/m3 (STP). We found such extremely pure nitrogen on the market and simulated experimentally the supply chain between a supplier and a customer in order to prove that it is possible to keep the purity under control. We discuss the obtained results and applied measurement techniques. Results of Ar purification tests from 222Rn, its oncentration measurements in a gas of different quality are also shown and compared with those obtained for nitrogen. Rn emanation from storage tanks is also discussed. (orig.)

  2. A liquid argon scintillation veto for GERDA and LArGe

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Bare germanium detectors are operated in a cryostat with 65 m3 of liquid argon (LAr). It has been demonstrated in the LArGe test facility, that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, that simultaneously deposit energy in LAr (LAr veto). Suppression factors up to 103 have been achieved for individual sources. Based on these results, Gerda pursues several options for the light instrumentation of LAr, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Qββ at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. Our main design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed. Their expected performance and progress of development is reported. In addition, results of the LArGe test facility are presented, along with the design criteria that follow for light instrumentation in Gerda.

  3. Pulse shape analysis of enriched BEGe detectors in vacuum cryostat and liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Victoria [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    The Gerda experiment searches for the lepton number violating neutrinoless double beta (0νββ) decay of {sup 76}Ge. Germanium diodes of BEGe type (Canberra, Belgium) made from isotopically modified material have been procured for Phase II of Gerda. They will improve the sensitivity of the experiment by additional target mass, improved energy resolution and enhanced pulse shape discrimination (PSD) against background events. The PSD efficiencies of the new enriched BEGe detectors were studied in vacuum cryostats as part of the characterization campaign at the HADES underground laboratory. For a deeper understanding of the pulse shape performance of the enriched BEGe detectors, detailed {sup 241}Am surface scans were performed. Unexpectedly high position-dependence of the pulse shape parameter Amplitude-over-Energy was found for some of the detectors. With further investigation this effect was traced to surface charge effects specific to the operational configuration of the detectors inside the vacuum cryostats. The standard behavior is restored when they are operated in liquid argon in the configuration intended for Gerda Phase II. Finally, five of the enriched BEGe diodes were installed in the Gerda liquid argon cryostat prior to the full upgrade. They show a good performance and are able to reject efficiently multi-site-events as well as β- and α-particles.

  4. An experimental study of atmospheric pressure dielectric barrier discharge (DBD) in argon

    Energy Technology Data Exchange (ETDEWEB)

    Subedi, D. P. [Department of Natural Sciences, School of Science, Kathmandu University, Dhulikhel (Nepal); Tyata, R. B. [Department of Natural Sciences, School of Science, Kathmandu University, Dhulikhel, Nepal and Department of Electrical, Khwopa College of Engineering, Libali-2, Bhaktapur (Nepal); Shrestha, R. [Department of Natural Sciences, School of Science, Kathmandu University, Dhulikhel, Nepal and Department of Physics, Basu College, Kalighat, Byasi, Bhaktapur (Nepal); Wong, C. S. [Plasma Technology Research Centre, Physics Department, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2014-03-05

    In this paper, experimental results on atmospheric pressure argon dielectric barrier discharge (DBD) have been presented. The discharge was generated using a high voltage (0 to 20 kV) power supply operating at frequency of 10 to 30 kHz and was studied by means of electrical and optical measurements. A homogeneous and steady discharge was observed between the electrodes with gap spacing from 1 mm to 3 mm and with a dielectric barrier of thickness 1.5 mm while argon gas is fed at a controlled flow rate of 2liter per min. The electron temperature (T{sub e}) and electron density (n{sub e}) of the plasma have been determined by means of optical emission spectroscopy. Our results show that the electron density is of the order of 10{sup 16} cm{sup −3} while the electron temperature is estimated to be ∼ 1 eV. The homogeneity and non-thermal nature of the discharge were utilized in the investigation of the change in wettabilty of a polymer sample subjected to the treatment by the discharge. Contact angle analysis showed that the discharge was effective in improving the wettability of low density Polyethylene (LDPE) polymer sample after the treatment.

  5. Equilibrium properties of transition-metal ion-argon clusters via simulated annealing

    Science.gov (United States)

    Asher, Robert L.; Micha, David A.; Brucat, Philip J.

    1992-01-01

    The geometrical structures of M(+) (Ar)n ions, with n = 1-14, have been studied by the minimization of a many-body potential surface with a simulated annealing procedure. The minimization method is justified for finite systems through the use of an information theory approach. It is carried out for eight potential-energy surfaces constructed with two- and three-body terms parametrized from experimental data and ab initio results. The potentials should be representative of clusters of argon atoms with first-row transition-metal monocations of varying size. The calculated geometries for M(+) = Co(+) and V(+) possess radial shells with small (ca. 4-8) first-shell coordination number. The inclusion of an ion-induced-dipole-ion-induced-dipole interaction between argon atoms raises the energy and generally lowers the symmetry of the cluster by promoting incomplete shell closure. Rotational constants as well as electric dipole and quadrupole moments are quoted for the Co(+) (Ar)n and V(+) (Ar)n predicted structures.

  6. Upgrade of the Trigger Readout System of the ATLAS Liquid Argon Calorimeters

    CERN Document Server

    Marino, CP; The ATLAS collaboration

    2014-01-01

    The ATLAS detector was designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to $10^{34} \\rm{cm}^{-2} \\rm{s}^{-1}$. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region $|\\eta|$ < 3.2, and for hadronic calorimetry in the region from $|\\eta|=$1.5 to $|\\eta|=$4.9. The ATLAS Liquid Argon (LAr) calorimeters produce a total of 182,486 signals which are digitized and processed by the front-end and back-end electronics at every triggered event. In addition, the front-end electronics sums analog signals to provide coarsely grained energy sums, called trigger towers, to the first-level trigger system, which is optimized for nominal LHC luminosities. In 2018, an instantaneous luminosity of 2-3 $\\times 10^{34} \\rm{cm}^{-2} \\rm{s}^{-1}$ is expected, far beyond the nominal one for which the detector was designed. In order to cope with this increased trigger rate,...

  7. Upgrade of the Trigger Readout System of the ATLAS Liquid Argon Calorimeters

    CERN Document Server

    Marino, CP; The ATLAS collaboration

    2013-01-01

    The ATLAS detector was designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to 10^34 cm^-2 s^-1. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region |eta|<3.2, and for hadronic calorimetry in the region from |eta|=1.5 to |eta|=4.9. The ATLAS Liquid Argon (LAr) calorimeters produce a total of 182,486 signals which are digitizedand processed by the front-end and back-end electronics at every triggered event. In addition, the front-end electronics sums analog signals to provide coarsely grained energy sums, called trigger towers, to the first-level trigger system, which is optimized for nominal LHC luminosities. In 2018, an instantaneous luminosity of 2-3 x 10^34 cm^-2 s^-1 is expected, far beyond the nominal one for which the detector was designed. In order to cope with this increased trigger rate, an improved spatial granularity of the trigger primi...

  8. Photoablation of ocular melanoma with a high-powered argon endolaser.

    Science.gov (United States)

    Jaffe, G J; Mieler, W F; Burke, J M; Williams, G A

    1989-01-01

    We studied the use of a 15-W argon blue-green laser in the treatment of choroidal melanoma in a rabbit model. Greene melanoma cells were used to produce 2- to 4-mm thick tumors posteriorly in the suprachoroidal space in pigmented rabbits. Endophotocoagulation delivered through a 600-micron fiberoptic probe was performed to ablate the tumor tissue and a surrounding margin of normal tissue. A vitreous cutter was used simultaneously to remove liberated necrotic debris. The effect of the laser on tumor and normal ocular tissue was evaluated by light microscopy and the extent of the proliferative response by tritiated thymidine radioautography. Application of 100 to 400 pulses of laser energy using treatment parameters of 12 to 14 W of power and 0.1-s pulses resulted in complete ablation of melanoma tissue, overlying retina, and choroid. There was no substantial intraoperative or postoperative hemorrhage. Material liberated during the laser treatment was found to be nonviable. The effect of the laser on tissue appeared localized to within approximately 1.25 mm of the margin of the central lesion. The high-energy argon laser seems to offer a means of effectively ablating melanoma tissue via an internal resection approach. PMID:2910269

  9. Alternating-gradient focusing of the benzonitrile-argon van der Waals complex.

    Science.gov (United States)

    Putzke, Stephan; Filsinger, Frank; Küpper, Jochen; Meijer, Gerard

    2012-09-14

    We report on the focusing and guiding of the van der Waals complex formed between benzonitrile molecules (C(6)H(5)CN) and argon atoms in a cold molecular beam using an ac electric quadrupole guide. The distribution of quantum states in the guided beam is non-thermal, because the transmission efficiency depends on the state-dependent effective dipole moment in the applied electric fields. At a specific ac frequency, however, the excitation spectrum can be described by a thermal distribution at a rotational temperature of 0.8 K. From the observed transmission characteristics and a combination of trajectory and Stark-energy calculations we conclude that the permanent electric dipole moment of benzonitrile remains unchanged upon the attachment of the argon atom to within ±5%. By exploiting the different dipole-moment-to-mass ([micro sign]/m) ratios of the complex and the benzonitrile monomer, transmission can be selectively suppressed for or, in the limit of 0 K rotational temperature, restricted to the complex. PMID:22979862

  10. Alternating-Gradient Focusing of the Benzonitrile-Argon Van der Waals Complex

    CERN Document Server

    Putzke, Stephan; Küpper, Jochen; Meijer, Gerard

    2012-01-01

    We report on the focusing and guiding of the van der Waals complex formed between benzonitrile molecules (C$_6$H$_5$CN) and argon atoms in a cold molecular beam using an ac electric quadrupole guide. The distribution of quantum states in the guided beam is non-thermal, because the transmission efficiency depends on the state-dependent effective dipole moment in the applied electric fields. At a specific ac frequency, however, the excitation spectrum can be described by a thermal distribution at a rotational temperature of 0.8 K. From the observed transmission characteristics and a combination of trajectory and Stark-energy calculations we conclude that the permanent electric dipole moment of benzonitrile remains unchanged upon the attachment of the argon atom to within \\pm5%. By exploiting the different dipole-moment-to-mass (\\mu/m) ratios of the complex and the benzonitrile monomer, transmission can be selectively suppressed for or, in the limit of 0 K rotational temperature, restricted to the complex.

  11. On the Role of Metastable Argon in Cold Atmospheric Pressure Plasma Jets with Shielding Gas Device

    Science.gov (United States)

    Schmidt-Bleker, Ansgar; Winter, Jorn; Sousa, Joao Santos; Puech, Vincent; Weltmann, Klaus-Dieter; Reuter, Stephan; ZIK plasmatis at the INP Greifswald e. V. Team; Laboratoire de Physique des Gaz et des Plasmas (LPGP), CNRS; Université Paris-Sud Team

    2014-10-01

    Shielding gas devices are a valuable tool for controlling the reactive species output of Cold Atmospheric Pressure Plasma (CAPP) Jets for biomedical applications. In this work we investigate the effect of different shielding gas compositions using a CAPP jet (kinpen) operated with argon. As shielding gas various mixtures of N2 and O2 are used. Metastable argon (Ar*) has been quantified using laser absorption spectroscopy and was identified as an important energy carrier in the CAPP jets effluent. The Ar* excitation dynamics was studied using phase resolve optical emission spectroscopy. Based on these findings a kinetic model for the gas phase chemistry has been developed that uses the Ar* density and dynamics as input and yields densities of O3, NO2, HNO2, HNO3, N2O5, H2O2 and N2O produced by the CAPP jet for different shielding gas compositions. The results are in good agreement with Fourier-Transform Infrared Spectroscopy measurements on these species. Authors gratefully acknowledge the funding by German Federal Ministry of Education a Research (BMBF) (Grant # 03Z2DN12).

  12. The monitoring and data quality assessment of the ATLAS liquid argon calorimeter

    CERN Document Server

    Simard, O

    2014-01-01

    The ATLAS experiment is designed to study the proton-proton ($pp$) collisions produced at the Large Hadron Collider (LHC) at CERN. Liquid argon (LAr) sampling calorimeters are used for all electromagnetic calorimetry in the pseudo-rapidity region $|\\eta|< 3.2$, as well as for hadronic calorimetry in the range $1.5 < |\\eta| < 4.9$. The electromagnetic calorimeters use lead as passive material and are characterized by an accordion geometry that allows a fast and uniform response without azimuthal gaps. Copper and tungsten were chosen as passive material for the hadronic calorimetry; while a classic parallel-plate geometry was adopted at large polar angles, an innovative design based on cylindrical electrodes with thin liquid argon gaps is employed at low angles, where the particle flux is higher. All detectors are housed in three cryostats maintained at about 88.5~K. The 182,468 cells are read out via front-end boards housed in on-detector crates that also contain monitoring, calibration, trigger and t...

  13. The monitoring and data quality assessment of the ATLAS liquid argon calorimeter

    CERN Document Server

    Simard, O; The ATLAS collaboration

    2014-01-01

    The ATLAS experiment is designed to study the proton-proton collisions produced at the Large Hadron Collider (LHC) at CERN. Liquid argon (LAr) sampling calorimeters are used for all electromagnetic calorimetry in the pseudo-rapidity region |η|< 3.2, as well as for hadronic calorimetry in the range 1.5<|η|<4.9. The electromagnetic calorimeters use lead as passive material and are characterized by an accordion geometry that allows a fast and uniform response without azimuthal gaps. Copper and tungsten were chosen as passive material for the hadronic calorimetry; while a classic parallel-plate geometry was adopted at large polar angles, an innovative design based on cylindrical electrodes with thin liquid argon gaps is employed for the coverage at low angles, where the particle flux is higher. All detectors are housed in three cryostats maintained at about 88.5K. The approximately 200K cells are read out via front-end boards housed in on-detector crates that also contain monitoring, calibration, trigg...

  14. Risk assessment of a cold argon plasma jet in respect to its mutagenicity.

    Science.gov (United States)

    Wende, K; Bekeschus, S; Schmidt, A; Jatsch, L; Hasse, S; Weltmann, K D; Masur, K; von Woedtke, T

    2016-03-01

    Cold atmospheric pressure plasmas represent a favorable option for the treatment of heat sensitive materials and human or animal tissue. Beneficial effects have been documented in a variety of medical conditions, e.g., in the treatment of chronic wounds. It is assumed that the main mechanism of the plasma's efficacy is mediated by a stimulating dissipation of energy via radiation and/or chemical energy. Although no evidence on undesired side effects of a plasma treatment has yet been presented, skepticism toward the safety of the exposure to plasma is present. However, only little data regarding the mutagenic potential of this new treatment option is available. Accordingly, we investigated the mutagenic potential of an argon plasma jet (kinpen) using different testing systems in accordance with ISO norms and multiple cell lines: a HPRT1 mutation assay, a micronucleus formation assay, and a colony formation assay. Moderate plasma treatment up to 180 s did not increase genotoxicity in any assay or cell type investigated. We conclude that treatment with the argon plasma jet kinpen did not display a mutagenic potential under the test conditions applied and may from this perspective be regarded as safe for the use in biomedical applications.

  15. Upgrade of the Trigger System of the ATLAS Liquid Argon calorimeters

    CERN Document Server

    Kanaya, N; The ATLAS collaboration

    2014-01-01

    The ATLAS detector was designed and build to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to 1034 cm^-2s^-1. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region |η| <3.2, and for hadronic calorimetry in the region from |η| = 1.5 to |η| = 4.9. The ATLAS Liquid Argon (LAr) calorimeters produce a total of 182,486 signals, which are digitized and processed by the front-end and back-end electronics for each triggered event. In addition, the front-end electronics sums analog signals to provide coarse-grained energy sums, called trigger towers, to the first-level trigger system, which is optimized for nominal LHC luminosities. In 2019, instantaneous luminosities of (2-3)×1034 cm^-2s^-1 are expected, far beyond that for which the detector was designed. In order to cope with this increased trigger rate, an improved spatial granularity of the trigger primitives is pro...

  16. Upgrade of the Trigger System of the ATLAS Liquid Argon calorimeters

    CERN Document Server

    Kanaya, N; The ATLAS collaboration

    2014-01-01

    ATLAS detector was designed and build to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to 1034 cm-2s-1. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region |η| <3.2, and for hadronic calorimetry in the region from |η| = 1.5 to |η| = 4.9. The ATLAS Liquid Argon (LAr) calorimeters produce a total of 182,486 signals, which are digitized and processed by the front-end and back-end electronics for each triggered event. In addition, the front-end electronics sums analog signals to provide coarse-grained energy sums, called trigger towers, to the first-level trigger system, which is optimized for nominal LHC luminosities. In 2020, instantaneous luminosities of (2-3)×1034 cm-2s-1 are expected, far beyond that for which the detector was designed. In order to cope with this increased trigger rate, an improved spatial granularity of the trigger primitives is proposed, t...

  17. ATLAS Liquid Argon Endcap Calorimeter R and D for sLHC

    CERN Document Server

    Schacht, P; The ATLAS collaboration

    2009-01-01

    The performance of the ATLAS liquid argon endcap has been studied for luminosities as expected for the operation at sLHC. The increase of integrated luminosity by a factor of ten has serious consequences for the signal reconstruction, radiation hardness requirements and operation of the forward liquid argon calorimeters. The response has been studied with small modules of the type as built for ATLAS in a very high intensity beam at IHEP/Protvino. The highest intensity obtained was well above the level of energy impact expected for ATLAS at sLHC. The signal processing of the ATLAS Hadronic Endcap Calorimeters employs the concept of 'active pads' which keeps the detector capacities at the input of the amplifiers small and thereby achieves a fast rise time of the signal. This concept is realized using highly integrated amplifier and summing chips in GaAs technology. With an increase of luminosity by a factor of ten the safety factor for the radiation hardness is essentially eliminated. Therefore new more radiati...

  18. ATLAS Liquid Argon Endcap Calorimeter R and D for sLHC

    CERN Document Server

    Schacht, P; The ATLAS collaboration

    2009-01-01

    The performance of the ATLAS liquid argon endcap has been studied for luminosities as expected for the operation at sLHC. The increase of integrated luminosity by a factor of ten has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the forward liquid argon calorimeters. The response has been studied with small modules of the type as built for ATLAS in a very high intensity beam at IHEP/Protvino. The highest intensity obtained was well above the level of energy impact expected for ATLAS at sLHC. The signal processing of the ATLAS Hadronic Endcap Calorimeter employs the concept of 'active pads' which keeps the detector capacities at the input of the amplifiers small and thereby achieves a fast rise time of the signal. This concept is realized using highly integrated amplifier and summing chips in GaAs technology. With an increase of luminosity by a factor of ten the safety factor for the radiation hardness is essentially eliminated. Therefore new more radiati...

  19. Long-term spatio-temporal evolution of the dust distribution in dusty argon rf plasmas

    Science.gov (United States)

    Killer, Carsten; Greiner, Franko; Groth, Sebastian; Tadsen, Benjamin; Melzer, André

    2016-10-01

    The 3D dust distribution in dense dust clouds confined in argon rf plasmas is measured by a computed tomography (CT) technique based on the extinction of visible light. On the one hand, clouds of micron-sized particles were created by injecting standardized plastic particles into the plasma. On the other hand, sub-micron sized dust with well-defined properties is grown in situ in an argon acetylene mixture. Once created, both kinds of dust clouds decay in the course of minutes to hours. This decay is monitored by CT measurements. It is revealed that micro-dust clouds feature a drastic change of the dust distribution due to a size reduction of the dust. Dust clouds of sub-micron particles, in contrast, show a strong variation of the overall dust density while the relative dust distribution remains nearly unchanged. The evolution of the overall dust density is subject to two effects: the loss of particles due to an imperfect confinement and the reduction of the dust size via etching.

  20. Radiating plasma species density distribution in EUV-induced plasma in argon: a spatiotemporal experimental study

    Science.gov (United States)

    van der Horst, R. M.; Beckers, J.; Osorio, E. A.; van de Ven, T. H. M.; Banine, V. Y.

    2015-12-01

    In this contribution we experimentally study temporally and spatially resolved radiating plasma species density distribution in plasma induced by irradiating a low pressure argon gas with high energy photons with a wavelength of 13.5 nm, i.e. extreme ultraviolet (EUV). This is done by recording the optical emission spatially and temporally resolved by an iCCD camera as a function of the argon gas pressure. Our experimental results show that the emission intensity, i.e. density of radiating plasma species, depends quadratically on the gas pressure. The linear term is due to photoionization and simultaneous excitation by EUV photons, the quadratic term due to electron impact excitation by electrons generated by photoionization. The decay of radiating plasma species can be divided into two phases. At time scales shorter than 10 μs (first phase), the decay is governed by radiative decay of radiating plasma species. At longer time scales (second phase, >10 μs), the decay is dominated by diffusion and subsequent de-excitation at the wall. The experimental decay and expansion during this phase corresponds well with a simplified diffusion model. In order to gain more insight in this exotic type of plasma, we compare the electron density from previous measurements with the results obtained here.

  1. A Demonstration of Light Guides for Light Detection in Liquid Argon TPCs

    Science.gov (United States)

    Ignarra, C. M.

    Liquid Argon (LAr) Time Projection Chambers (TPCs) are a developing technology that is becoming a popular choice for neutrino and dark matter experiments due to the low cost of the LAr as a target material and the high signal effciency and background rejection that these detectors can achieve. When excited by a passing charged particle created in a neutrino interaction, argon produces scintillation light at 128 nm. Several types of systems exist for detecting this light. Most involve shifting the wavelength of the light using Tetraphenyl Butadiene (TPB), resulting in visible light which is detected by a PMT.I will discuss our work on a new system under development for light detection in LAr which uses acrylic lightguides. The lightguides are coated with a thin film consisting of TPB embedded in polystyrene. This system could provide a solution to some of the issues associated with scaling existing systems for a larger future LAr detector. Though we are only in the preliminary stages of this R&D, we have shown that the results are already suffcient for triggering.

  2. Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping

    Science.gov (United States)

    Wahl, C. G.; Bernard, E. P.; Lippincott, W. H.; Nikkel, J. A.; Shin, Y.; McKinsey, D. N.

    2014-06-01

    Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in light or signal yield, energy resolution, and particle discrimination. In this study, we investigate the detector response for xenon dopant concentrations from 9 ± 5 ppm to 1100 ± 500 ppm xenon (by weight) in 6 steps. The 3.14-liter detector uses tetraphenyl butadiene (TPB) wavelength shifter with dual photomultiplier tubes and is operated in single-phase mode. Gamma-ray-interaction signal yield of 4.0 ± 0.1 photoelectrons/keV improved to 5.0 ± 0.1 photoelectrons/keV with dopant. Energy resolution at 662 keV improved from (4.4 ± 0.2)% (σ) to (3.5 ± 0.2)% (σ) with dopant. Pulse-shape discrimination performance degraded greatly at the first addition of dopant, slightly improved with additional additions, then rapidly improved near the end of our dopant range, with performance becoming slightly better than pure argon at the highest tested dopant concentration. Some evidence of reduced neutron scintillation efficiency with increasing dopant concentration was observed. Finally, the waveform shape outside the TPB region is discussed, suggesting that the contribution to the waveform from xenon-produced light is primarily in the last portion of the slow component.

  3. Characterization of CdZnTe after argon ion beam bombardment

    Energy Technology Data Exchange (ETDEWEB)

    Bensalah, H., E-mail: hakima.bensalah@uam.es [Departamento de Fisica de Materiales, Laboratorio de Crecimiento de Cristales, Facultad de Ciencias, Universidad Autonoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Hortelano, V. [GdS-Optronlab Group, Departamento Fisica Materia Condensada, Universidad de Valladolid, Edificio I-D, Paseo de Belen 1, 47011 Valladolid (Spain); Plaza, J.L. [Departamento de Fisica de Materiales, Laboratorio de Crecimiento de Cristales, Facultad de Ciencias, Universidad Autonoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Martinez, O. [GdS-Optronlab Group, Departamento Fisica Materia Condensada, Universidad de Valladolid, Edificio I-D, Paseo de Belen 1, 47011 Valladolid (Spain); Crocco, J.; Zheng, Q.; Carcelen, V.; Dieguez, E. [Departamento de Fisica de Materiales, Laboratorio de Crecimiento de Cristales, Facultad de Ciencias, Universidad Autonoma de Madrid, Cantoblanco, 28049 Madrid (Spain)

    2012-12-05

    Highlights: Black-Right-Pointing-Pointer After argon irradiation using low fluence, the defects on surface were removed. Black-Right-Pointing-Pointer The PL intensity increases after irradiation. This increase should be related to the improved quality of the CdZnTe surfaces. Black-Right-Pointing-Pointer Irradiation process lead to an elimination of Te precipitates from the surfaces of the CdZnTe samples. - Abstract: The objective of this work is to analyze the effects of argon ion irradiation process on the structure and distribution of Te inclusions in Cd{sub 1-x}Zn{sub x}Te crystals. The samples were treated with different ion fluences ranging from 2 to 8 Multiplication-Sign 10{sup 17} cm{sup -2}. The state of the samples before and after irradiation were studied by Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), Cathodoluminescence, Photoluminescence, and micro-Raman spectroscopy. The effect of the irradiation on the surface of the samples was clearly observed by SEM or AFM. Even for small fluences a removal of polishing scratches on the sample surfaces was observed. Likely correlated to this effect, an important enhancement in the luminescence intensity of the irradiated samples was observed. An aggregation effect of the Te inclusions seems to occur due to the Ar bombardment, which are also eliminated from the surfaces for the highest ion fluences used.

  4. Particle-in-Cell Modeling of Magnetized Argon Plasma Flow Through Small Mechanical Apertures

    Energy Technology Data Exchange (ETDEWEB)

    Adam B. Sefkow and Samuel A. Cohen

    2009-04-09

    Motivated by observations of supersonic argon-ion flow generated by linear helicon-heated plasma devices, a three-dimensional particle-in-cell (PIC) code is used to study whether stationary electrostatic layers form near mechanical apertures intersecting the flow of magnetized plasma. By self-consistently evaluating the temporal evolution of the plasma in the vicinity of the aperture, the PIC simulations characterize the roles of the imposed aperture and applied magnetic field on ion acceleration. The PIC model includes ionization of a background neutral-argon population by thermal and superthermal electrons, the latter found upstream of the aperture. Near the aperture, a transition from a collisional to a collisionless regime occurs. Perturbations of density and potential, with mm wavelengths and consistent with ion acoustic waves, propagate axially. An ion acceleration region of length ~ 200-300 λD,e forms at the location of the aperture and is found to be an electrostatic double layer, with axially-separated regions of net positive and negative charge. Reducing the aperture diameter or increasing its length increases the double layer strength.

  5. Operating Instructions for the Cryogenics in the Liquid Argon Detector at CIEMAT

    International Nuclear Information System (INIS)

    Ciemat has wide experience in designing and developing gaseous particle detectors. It has taken part in the building of experiments for CERN accelerators, constructing shares of the muon chambers for L3 experiment in LEP and CMS experiment in LHC. Recently, new concepts for particle detectors have been developed, as a natural evolution from the ones built at Ciemat. These new radiation detectors use liquefied noble gases as active media. A testing system for these kind of liquefied argon detectors has been built at Ciemat, and includes a supporting cryogenic system for the liquefaction and maintenance of the liquid argon needed for operating the detector. This document describes the technical features of this cryogenic system. Besides the documentation of the cryogenic system, this technical report can be of help for the management and upgrading of the detector. As well as an introduction, the report includes the following chapters: The second one is a description of the cryogenics and gas systems. The third chapter shows the controlling electronics. The fourth chapter deals with the important topic that is security, its systems and protocols. The fifth describes the cryogenic operations possible in this equipment. The report is completed with diagrams, schemes, pictures and tables for the easier management of the setup. (Author)

  6. a Liquid Argon Time Projection Chamber for the Solar Neutrino Problem

    Science.gov (United States)

    Cheng, Mao-Tung

    The construction and successful test of a large liquid argon time projection chamber prototype detector is presented. This effort is a part of the ICARUS project which is aimed at the development of new detector techniques to uncover the very rare events like proton decay and solar neutrinos. The construction and test of this detector has been carried out at CERN from 1989 until the present time. The charge lifetime measured is 3.19 +/- 0.13 ms. We also report on a precision measurement of lifetime by a laser monitoring chamber and the operation of the recirculation system essential to keeping liquid for a long time. We show that a liquid argon detector is very well suited to study mass-enhanced neutrino oscillation (MSW effect) from the Sun by detecting simultaneous two modes of reaction. Ratio of two modes provides a model independent probe of neutrino oscillation, free of deviations from different solar models. Contour plots are presented at various threshold energies.

  7. Study of a contracted glow in low-frequency plasma-jet discharges operating with argon

    Energy Technology Data Exchange (ETDEWEB)

    Minotti, F.; Giuliani, L.; Xaubet, M.; Grondona, D. [Departamento de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires, C1428EHA, Buenos Aires, Argentina and Instituto de Física del Plasma (INFIP), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Universidad de Buenos Aires - UBA, C1428EHA, Buenos Aires (Argentina)

    2015-11-15

    In this work, we present an experimental and theoretical study of a low frequency, atmospheric plasma-jet discharge in argon. The discharge has the characteristics of a contracted glow with a current channel of submillimeter diameter and a relatively high voltage cathode layer. In order to interpret the measurements, we consider the separate modeling of each region of the discharge: main channel and cathode layer, which must then be properly matched together. The main current channel was modeled, extending a previous work, as similar to an arc in which joule heating is balanced by lateral heat conduction, without thermal equilibrium between electrons and heavy species. The cathode layer model, on the other hand, includes the emission of secondary electrons by ion impact and by additional mechanisms, of which we considered emission due to collision of atoms excited at metastable levels, and field-enhanced thermionic emission (Schottky effect). The comparison of model and experiment indicates that the discharge can be effectively sustained in its contracted form by the secondary electrons emitted by collision of excited argon atoms, whereas thermionic emission is by far insufficient to provide the necessary electrons.

  8. ATLAS Liquid Argon Calorimeter Performance in Run 1 and Run 2

    CERN Document Server

    Kuwertz, Emma Sian; The ATLAS collaboration

    2016-01-01

    The ATLAS detector was designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to $10^{34}$ cm$^{−2}$ s$^{−1}$ . Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudo-rapidity region $\\eta < 3.2$, and for hadronic calorimetry in the region from $\\eta = 1.5$ to $\\eta = 4.9$. In the first LHC run a total luminosity of $27$ fb$^{−1}$ has been collected at center-of-mass energies of 7-8 TeV. Following a period of detector consolidation during a long shutdown, Run-2 started in 2015 with approximately $3.9$ fb$^{-1}$ of data at a center-of-mass energy of 13 TeV recorded in this year. The well calibrated and highly granular Liquid Argon Calorimeter achieved its design values both in energy measurement as well as in direction resolution, which was a main ingredient for the successful discovery of a Higgs boson in the di-photon decay channel. This contribution will give ...

  9. First steps towards the reaction kinetics of HMDSO in an atmospheric pressure plasma jet in argon

    Science.gov (United States)

    Loffhagen, Detlef; Becker, Markus M.; Foest, Rüdiger; Schäfer, Jan; Sigeneger, Florian

    2014-10-01

    Hexamethyldisiloxane (HMDSO) is a silicon-organic compound which is often used as precursor for thin-film deposition by means of plasma polymerization because of its high deposition rate and low toxicity. To improve the physical understanding of the deposition processes, fundamental investigations have been performed to clarify the plasma-chemical reaction pathways of HMDSO and their effect on the composition and structure of the deposited film. The current contribution represents the main primary and secondary plasma-chemical processes and their reaction products in the effluent region of an argon plasma jet at atmospheric pressure. The importance of the different collision processes of electrons and heavy particles are discussed. Results of numerical modelling of the plasma jet and the Ar-HMDSO reaction kinetics indicate that the fragmentation of HMDSO is mainly initiated by collisions with molecular argon ions, while Penning ionization processes play a minor role for the reaction kinetics in the effluent region of the jet. The work has been supported by the German Research Foundation (DFG) under Grant LO 623/3-1.

  10. Investigation of forbidden transitions in argon ions. [in laboratory plasma for solar corona simulation

    Science.gov (United States)

    Jalufka, N. W.

    1976-01-01

    An attempt has been made to observe the visible forbidden argon coronal lines at 553.6 nm (Ar X), 691.7 nm (Ar XI), 847.6 nm (Ar XIII), and 441.2 nm (Ar XIV) in a deuterium-argon plasma produced in a large theta pinch. The electron temperature (250 eV) and the electron density (5 by 10 to the 16th power per cu cm) were measured by Thomson scattering of ruby laser radiation. This temperature is adequate to produce ionization stages up to Ar XIV, as was verified by photographic observation of Ar XIV lines. No line corresponding to the coronal lines was observed from the high-temperature plasma, but lines with wavelengths very nearly identical to those of two of the forbidden transitions were observed; these lines were due to allowed transitions of Ar II in a cooler portion of the plasma. Calculation of rate coefficients in the Coulomb-Born approximation shows that for laboratory experiments, electron collisions are much more important than radiative decay in depopulating the upper state of the forbidden lines.

  11. An experimental study of atmospheric pressure dielectric barrier discharge (DBD) in argon

    International Nuclear Information System (INIS)

    In this paper, experimental results on atmospheric pressure argon dielectric barrier discharge (DBD) have been presented. The discharge was generated using a high voltage (0 to 20 kV) power supply operating at frequency of 10 to 30 kHz and was studied by means of electrical and optical measurements. A homogeneous and steady discharge was observed between the electrodes with gap spacing from 1 mm to 3 mm and with a dielectric barrier of thickness 1.5 mm while argon gas is fed at a controlled flow rate of 2liter per min. The electron temperature (Te) and electron density (ne) of the plasma have been determined by means of optical emission spectroscopy. Our results show that the electron density is of the order of 1016 cm−3 while the electron temperature is estimated to be ∼ 1 eV. The homogeneity and non-thermal nature of the discharge were utilized in the investigation of the change in wettabilty of a polymer sample subjected to the treatment by the discharge. Contact angle analysis showed that the discharge was effective in improving the wettability of low density Polyethylene (LDPE) polymer sample after the treatment

  12. An experimental study of atmospheric pressure dielectric barrier discharge (DBD) in argon

    Science.gov (United States)

    Subedi, D. P.; Tyata, R. B.; Shrestha, R.; Wong, C. S.

    2014-03-01

    In this paper, experimental results on atmospheric pressure argon dielectric barrier discharge (DBD) have been presented. The discharge was generated using a high voltage (0 to 20 kV) power supply operating at frequency of 10 to 30 kHz and was studied by means of electrical and optical measurements. A homogeneous and steady discharge was observed between the electrodes with gap spacing from 1 mm to 3 mm and with a dielectric barrier of thickness 1.5 mm while argon gas is fed at a controlled flow rate of 2liter per min. The electron temperature (Te) and electron density (ne) of the plasma have been determined by means of optical emission spectroscopy. Our results show that the electron density is of the order of 1016 cm-3 while the electron temperature is estimated to be ˜ 1 eV. The homogeneity and non-thermal nature of the discharge were utilized in the investigation of the change in wettabilty of a polymer sample subjected to the treatment by the discharge. Contact angle analysis showed that the discharge was effective in improving the wettability of low density Polyethylene (LDPE) polymer sample after the treatment.

  13. Cryotherapy of employing Argon/Helium assisted with TACE in treating unresectable primary liver carcinoma

    International Nuclear Information System (INIS)

    Objective: To investigate the effect of cryotherapy of employing Argon/Helium assisted with TACE for the unresectable primary liver carcinoma. Methods: 124 cases with primary liver carcinoma were randomly divided into two groups: 60 cases were treated by TACE and cryotherapy; the other 64 cases were simply done by TACE as control. In general, TACE was undertaken once a month and altogether three times for a course. Cryotherapy was undergone 1-3 times for a course. Results: The total effective rates (CR + PR) were 45.3% for the control group and 68.3% for the combined therapy group, with an obvious difference between the two groups, 0.5, 1, 1.5 years survival rate were 81.3%, 62.5%, 43.8% respectively in the control group; 93.3%, 83.3%, 63.3% respectively for the combined group. There was an obvious difference between the two groups of 1, 1.5 years of survival rates. Conclusions: Cryotherapy of employing Argon/Helium assisted with TACE for the unresectable primary liver carcinoma is feasible with raising the effective rate and prolonging survival time. (authors)

  14. Investigation of the thermal and photochemical reactions of ozone with styrene in argon and krypton matrices

    Science.gov (United States)

    Coleman, Bridgett E.; Ault, Bruce S.

    2012-09-01

    The matrix isolation technique, combined with infrared spectroscopy and twin jet codeposition, has been used to characterize intermediates formed during the ozonolysis of styrene. Absorptions assigned to early intermediates grew in after warming the matrix from 19 K to 68 K in the twin jet krypton matrix experiments. A number of these absorptions have been assigned to the primary ozonide, formaldehyde-O-oxide Criegee intermediate, and secondary ozonide of styrene, transient species not previously observed for this system. In contrast, the room temperature reaction of ozone with styrene led to the observation of "late," stable products of this ozonolysis reaction. These product absorptions were observed after merged jet deposition, followed by cryogenic trapping in solid argon. Irradiation with λ ⩾ 220 nm of merged and twin jet argon matrices involving ozone led to O atom production and subsequent reaction with styrene. Identification of intermediates formed during the ozonolysis of styrene was further supported by 18O isotopic labeling experiments as well as theoretical density functional calculations at the B3LYP/6-311G++(d,2p) level.

  15. Second-Order Born Effect in Single Ionization of Argon by Electron Impact

    Institute of Scientific and Technical Information of China (English)

    WANG Yang; ZHOU Ya-Jun; JIAO Li-Guang

    2012-01-01

    We extend the standard distorted wave Born approximation (DWBA) to include the second-order Born amplitude in order to describe the multiple interactions between a projectile and an atomic target. Both the first- and second-order DWBA models are used to calculate triply differential cross sections (TDCS) of coplanar (e,2e) on atomic argon with the scattered electron energy fixed at 500 eV, the scattering angle at 6° and the ejected electron energies at 37, 74 and 205 eV. Overall agreements with experimental measurements have been obtained in shape, and the second-order DWBA model improves the calculations as expected, especially for recoil peak of TDCS.%We extend the standard distorted wave Born approximation (DWBA ) to include the second-order Born amplitude in order to describe the multiple interactions between a projectile and an atomic target.Both the first- and secondorder DWBA models are used to calculate triply differential cross sections (TDCS) of coplanar (e,2e) on atomic argon with the scattered electron energy fixed at 500eV,the scattering angle at 6° and the ejected electron energies at 37,74 and 205 e V.Overall agreements with experimental measurements have been obtained in shape,and the second-order DWBA model improves the calculations as expected,especially for recoil peak of TDCS.

  16. The effect of potassium addition on plasma parameters in argon dc plasma arc

    Energy Technology Data Exchange (ETDEWEB)

    Rankovic, D; Kuzmanovic, M [Faculty of Physical Chemistry, University of Belgrade, PO Box 137, 11000 Belgrade (Serbia); Savovic, J; Pavlovic, M S; Stoiljkovic, M; Momcilovic, M, E-mail: dragan@ffh.bg.ac.r [Laboratory of Physical Chemistry, Institute Vinca, University of Belgrade, PO Box 522, 11001 Belgrade (Serbia)

    2010-08-25

    The effect of potassium addition on the radial distribution of temperature and electron number density in a U-shaped direct current (dc) argon plasma operating at different arc currents has been studied by optical emission spectroscopic techniques and the power interruption method. Spatially resolved electron number densities (n{sub e}) have been determined from measured radial profiles of Balmer-H{sub {beta}} spectral line. The obtained electron number densities have been used for thermodynamic temperature (T{sub LTE}) evaluation with the assumption that the arc plasma is in a state of local thermodynamic equilibrium. The excitation temperatures (T{sub exc}) have been determined from the absolute integral emissivity of the argon line at 430.01 nm. For heavy particle temperature (T{sub h}) evaluations we have used a power interruption method. The obtained results have shown that an addition of KCl decreases both electron number density and temperature of the arc column. The magnitude of such an influence on plasma parameters increases with an increase in the KCl concentration and decreases with an increase in the arc current.

  17. Resource Review Board Celebrates the Magnet and Liquid Argon Barrel Tests in Hall 180

    CERN Multimedia

    Jenni, P.

    2004-01-01

    Address by the Director-General, R. Aymar, in front of the barrel cryostat. On 25th October 2004 many RRB delegates and guests, ATLAS National Contact Physicists, and colleagues from far and from CERN working on the Liquid Argon calorimeter and the magnet system were gathering in Hall 180 to celebrate the major milestones reached during the past months in this hall: the successful cold tests of the first barrel toroid coil, of the solenoid, and of the barrel Liquid Argon calorimeter. About 250 people spent a relaxing evening after the speeches by the Director-General R. Aymar and by the spokesperson who gave the following address: 'It is a great pleasure for me to welcome you all here in Hall 180 in the name of the ATLAS Collaboration! With a few words I would like to recall why we are actually here today to share, what I hope, is a relaxed and joyful moment. To concentrate it all in one sentence I could say: To thank cordially all the main actors for the enormous work accomplished here over many years,...

  18. Argon and nitrogen beams influencing membrane permeate fluxes and microbial growth

    Energy Technology Data Exchange (ETDEWEB)

    Wanichapichart, P., E-mail: pikul.v@psu.ac.t [Membrane Science and Technology Research Center, Department of Physics, Prince of Songkla University (Thailand); NANOTEC Center of Excellence at Prince of Songkla University, Prince of Songkla University (Thailand); Taweepreeda, W. [Membrane Science and Technology Research Center, Polymer Science Programme, Prince of Songkla University (Thailand); NANOTEC Center of Excellence at Prince of Songkla University, Prince of Songkla University (Thailand); Choomgan, P. [Membrane Science and Technology Research Center, Department of Physics, Prince of Songkla University (Thailand); Yu, L.D. [Fast Neutron Research Facility, Department of Physics, Chiang Mai University (Thailand)

    2010-03-15

    Porous cellulose and dense chitosan membranes were bombarded with argon and nitrogen-ion beams using two energy levels, 30 and 120 keV, of the same fluency of 5x10{sup 14} ions/cm{sup 2} for a comparison study. The results revealed that both beam types reduced the hydraulic permeability of the membranes. Using a NaCl solution of 4000 ppm concentration as feed, the ability to reject salt of dense chitosan membrane was reduced only if it was pretreated with 120 keV nitrogen-ion beams. A Fourier Transform Infrared Spectroscopy study showed that molecular weight of chitosan was possibly decreased after the bombardment with 120 keV beams. The analysis of the cellulose membranes revealed that a dense structure was created without affecting the OH functional groups. This study found that only chitosan membranes possessed an anti-fungi property if being implanted with positive charges of nitrogen or argon ions of 120 keV.

  19. Argon laser iridoplasty : A primary mode of therapy in primary angle closure glaucoma

    Directory of Open Access Journals (Sweden)

    Agarwal H

    1991-01-01

    Full Text Available Argon laser iridoplasty was performed in 40 eyes of 33 patients of primary angle closure glaucoma. There were 12 male and 21 female patients. The mean ages of the male and female patients were 51 years and 48.4 years respectively. Forty eyes were divided into two groups. Group I consisted of ten eyes of subacute angle closure glaucoma and group II included thirty eyes of chronic angle closure glaucoma. Argon laser iridoplasty was performed with Coherent 9000 model using laser settings of spot size 200 micron, duration 0.2 second and power 0.7 watt. A total of 80 spots were applied over 360 degree circumference. The intraocular pressure control (below 22 mm Hg was achieved after iridoplasty in all the eyes (100% in group I, where as in group II the intraocular pressure was controlled in 70% eyes. The follow up period varied from 3 months to one year with a mean of eight months. The success rate with iridoplasty was directly related to the extent of peripheral anterior synechiae, optic disc cupping and presence of visual field changes.

  20. Generation of uniform atmospheric pressure argon glow plasma by dielectric barrier discharge

    Indian Academy of Sciences (India)

    Raju Bhai Tyata; Deepak Prasad Subedi; Rajendra Shrestha; Chiow San Wong

    2013-03-01

    In this paper, atmospheric pressure glow discharges (APGD) in argon generated in parallel plate dielectric barrier discharge system is investigated by means of electrical and optical measurements. Using a high voltage (0–20 kV) power supply operating at 10–30 kHz, homogeneous and steady APGD has been observed between the electrodes with gap spacing from 0.5 mm to 2 mm and with a dielectric barrier of thickness 2 mm while argon gas is fed at a controlled flow rate of 11/min. The electron temperature and electron density of the plasma are determined by means of optical emission spectroscopy. Our results show that the electron density of the discharge obtained is of the order of 1016 cm-3 while the electron temperature is estimated to be 0.65 eV. The important result is that electron density determined from the line intensity ratio method and stark broadening method are in very good agreement. The Lissajous figure is used to estimate the energy deposited to the glow discharge. It is found that the energy deposited to the discharge is in the range of 20 to 25 $\\$J with a discharge voltage of 1.85 kV. The energy deposited to the discharge is observed to be higher at smaller gas spacing. The glow discharge plasma is tested to be effective in reducing the hydrophobicity of polyethylene film significantly.

  1. Spectroscopic assessment of argon gas discharge induced radiolysis of aqueous adenine and thymine

    International Nuclear Information System (INIS)

    Ionizing radiation influences life profoundly for it can modify genetic materials. It is a long-standing task to investigate the interaction between energetic particles and DNA together with its components such as nucleotides, nucleosides and bases so as to predict and assess the potential biological effects. In this study, argon gas discharge was employed to produce energetic ions and electrons. The gas discharge caused the radiolysis of aqueous bases and the involved reactions were analyzed by means of spectroscopic tools including UV-vis absorption, fluorescence and Fourier transformation infrared (FTIR) spectroscopy, also assisted by liquid chromatography/mass spectrometry (LC/MS). It was found that the discharge resulted in the adenine-derived lesions such as 4,6-diamino-5-formamidopyrimidine, 8-OH-Ade and 2-OH-Ade in the radiolysis of aqueous adenine, as well as the thymine-derived lesions such as thymine glycol, 5-hydroxy-6-hydrothymine and/or 6-hydroxy-5-hydrothymine, 5-hydroxymethyluracil and 5-formyluracil in the radiolysis of aqueous thymine. The study of radio-sensitivity showed that adenine was more resistant to the discharge. The mechanisms of the involved reactions were studied in detail, confirming that the hydroxyl radical played a dominant role. - Highlights: → Effective new way to study radiolysis of bases via a home-made argon discharge apparatus. → Quantitative analysis of base radiolysis employing spectroscopic tools combined with HPLC/MS. Discovery of different radiolysis effect compared with other forms of ionizing radiations.

  2. Spectroscopic assessment of argon gas discharge induced radiolysis of aqueous adenine and thymine

    Energy Technology Data Exchange (ETDEWEB)

    Su Xi [Key Laboratory of Ion Beam Bio-engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, P.O. Box 1138, Shushanhu Road 350, Hefei 230031 (China); Huang Qing, E-mail: huangq@ipp.ac.cn [Key Laboratory of Ion Beam Bio-engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, P.O. Box 1138, Shushanhu Road 350, Hefei 230031 (China); Dang Bingrong [Institute of Modern Physics, Chinese Academy of Sciences, 509 Nanchang Road, Lanzhou 730000 (China); Wang Xiangqin; Yu Zengliang [Key Laboratory of Ion Beam Bio-engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, P.O. Box 1138, Shushanhu Road 350, Hefei 230031 (China)

    2011-12-15

    Ionizing radiation influences life profoundly for it can modify genetic materials. It is a long-standing task to investigate the interaction between energetic particles and DNA together with its components such as nucleotides, nucleosides and bases so as to predict and assess the potential biological effects. In this study, argon gas discharge was employed to produce energetic ions and electrons. The gas discharge caused the radiolysis of aqueous bases and the involved reactions were analyzed by means of spectroscopic tools including UV-vis absorption, fluorescence and Fourier transformation infrared (FTIR) spectroscopy, also assisted by liquid chromatography/mass spectrometry (LC/MS). It was found that the discharge resulted in the adenine-derived lesions such as 4,6-diamino-5-formamidopyrimidine, 8-OH-Ade and 2-OH-Ade in the radiolysis of aqueous adenine, as well as the thymine-derived lesions such as thymine glycol, 5-hydroxy-6-hydrothymine and/or 6-hydroxy-5-hydrothymine, 5-hydroxymethyluracil and 5-formyluracil in the radiolysis of aqueous thymine. The study of radio-sensitivity showed that adenine was more resistant to the discharge. The mechanisms of the involved reactions were studied in detail, confirming that the hydroxyl radical played a dominant role. - Highlights: > Effective new way to study radiolysis of bases via a home-made argon discharge apparatus. > Quantitative analysis of base radiolysis employing spectroscopic tools combined with HPLC/MS. > Discovery of different radiolysis effect compared with other forms of ionizing radiations.

  3. Monitoring Liquid Argon Time Projection Chambers With A Raspberry Pi Camera

    Science.gov (United States)

    Patteson, Crystal

    2016-03-01

    The MicroBooNE detector is the first of three liquid argon (LAr) time projection chambers (TPCs) that are central to the short-baseline neutrino program at Fermilab. These chambers consist of thousands of stainless steel or beryllium-copper sense wires that detect ionization electrons produced when neutrinos interact with liquid argon nuclei inside the detector. The wires are several hundred microns in diameter to several meters in length. The construction of such LAr TPCs often takes place in an assembly hall, which is different from the detector hall where the experiment will operate, as was the case with MicroBooNE. Since in situ access to the chamber and its wires in the beamline enclosure can be limited, we investigate the possibility of using a Raspberry Pi single-board computer connected to a low-cost camera installed inside the cryostat as a cost-efficient way to verify the integrity of the wires after transport. We also highlight other benefits of this monitoring device implemented in MicroBooNE, including detector hall surveillance and verification of the status of LED indicators on detector electronics. The author would like to thank Dr. Matthew Toups for his encouragement and guidance on this research project.

  4. Neuroprotective effects of Argon are mediated via an ERK-1/2 dependent regulation of heme-oxygenase-1 in retinal ganglion cells.

    Science.gov (United States)

    Ulbrich, Felix; Kaufmann, Kai B; Coburn, Mark; Lagrèze, Wolf Alexander; Roesslein, Martin; Biermann, Julia; Buerkle, Hartmut; Loop, Torsten; Goebel, Ulrich

    2015-08-01

    Retinal ischemia and reperfusion injuries (R-IRI) damage neuronal tissue permanently. Recently, we demonstrated that Argon exerts anti-apoptotic and protective properties. The molecular mechanism remains unclear. We hypothesized that Argon inhalation exert neuroprotective effects in rats retinal ganglion cells (RGC) via an ERK-1/2 dependent regulation of heat-shock proteins. Inhalation of Argon (75 Vol%) was performed after R-IRI on the rats' left eyes for 1 h immediately or with delay. Retinal tissue was harvested after 24 h to analyze mRNA and protein expression of heat-shock proteins -70, -90 and heme-oxygenase-1, mitogen-activated protein kinases (p38, JNK, ERK-1/2) and histological changes. To analyze ERK dependent effects, the ERK inhibitor PD98059 was applicated prior to Argon inhalation. RGC count was analyzed 7 days after injury. Statistics were performed using anova. Argon significantly reduced the R-IRI-affected heat-shock protein expression (p ERK-1/2 expression (p ERK-1/2 before Argon inhalation resulted in significantly lower vital RGCs (p ERK-1/2 activation in Müller cells. We conclude, that Argon treatment protects R-IRI-induced apoptotic loss of RGC via an ERK-1/2 dependent regulation of heme-oxygenase-1. We proposed the following possible mechanism for Argon-mediated neuroprotection: Argon exerts its protective effects via an induction of an ERK with subsequent suppression of the heat shock response. In conclusion, ischemia and reperfusion injuries and subsequent neuronal apoptosis are attenuated. These novel findings may open up new opportunities for Argon as a therapeutic option, especially since Argon is not toxic.

  5. Argon laser phototherapy of human malignancies using rhodamine-123 as a new laser dye: The intracellular role of oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Castro, D.J.; Saxton, R.E.; Markley, J.; Foote, C.S.; Fetterman, H.R.; Castro, D.J.; Ward, P.H. (Univ. of California, Los Angeles (USA))

    1990-08-01

    Recent studies demonstrated that the cationic, mitochondrial-specific dye Rhodamine-123 (Rh-123), is an efficient tumor photosensitizer for Argon laser treatment of human cancer cells both in vitro and in tumors grown as xenografts in athymic mice. To demonstrate the photodynamic mechanism of action of this reaction, the intracellular role of oxygen and temperature changes in treated cells have to be defined. In the current study, a large panel of human tumor cell lines of diverse histologic origin were tested for in vitro sensitivity to Rh-123 and the Argon laser (514.5 nm) in oxygen, deuterium oxide (D2O), and nitrogen (N2) environment. Tumor cells in suspension were first sensitized to Rh-123 (1 or 20 micrograms/ml for 1 hour), cooled on ice to 4 degrees C, and then exposed to the Argon laser (delta T = 14 +/- 1 degree C). Cell proliferation measured by (3H)-thymidine uptake 24 hours after sensitization with Rh-123 and laser treatment was significantly decreased in tumor cells kept in oxygen and D2O atmospheres. No decrease in DNA synthesis was seen in Rh-123 and laser treated cells kept in an N2 environment. Control tumor cells treated with Rh-123 or the Argon laser separately did not show any decreased (3H)-thymidine uptake in oxygen, D2O or N2 environment. These results provide evidence of a photodynamic process since Rh-123 sensitization and Argon laser activation occur at nonthermal levels of energy and are oxygen dependent. The high effectiveness of this technique of photodynamic therapy with the Argon laser, and low toxicity of Rh-123 could make its clinical use very attractive for the treatment of superficial malignancies.

  6. Effects of argon enriched low-oxygen atmospheres and of high-oxygen atmospheres on the kinetics of polyphenoloxidase (PPO).

    Science.gov (United States)

    O'Beirne, David; Murphy, Eileen; Ni Eidhin, Deirdre

    2011-01-01

    The reported benefits of enrichment of air atmospheres with argon or oxygen for control of enzymatic browning were investigated by determining the effects of these atmospheres on PPO kinetics. Kinetics of purified apple PPO and a commercially available mushroom PPO were studied in an in vitro model system. Enrichment with argon produced greater inhibitory effects than the current industry practice of enrichment with nitrogen. Km(app) values (mM) for apple PPO in 3%O(2)/97%Ar, 3%O(2)/97%N(2), and air, were 133, 87, and 48, respectively. The data indicate that inhibition by both gases is competitive, and also support the hypothesis that the greater inhibitory effect of argon was proportional to the size of the Van der Waals radius of argon against nitrogen (1.91 Å against 1.54 Å). Much smaller inhibitory effects were observed in the presence of 80% O(2) (Km(app) 57 mM), and the nature of this inhibition was less clear. The results suggest that the benefits of argon enrichment may be relatively small, and may require critical enzyme, substrate, and gas levels to be successful. However, these benefits may be exploitable commercially in some fresh-cut products, and may allow less anoxic atmospheres to be used. Practical Application: Control of enzymatic browning without sulfites continues to be a challenge in some fresh-cut products. While sporadic benefits of these atmospheres in control of enzymatic browning have been reported, results have been inconsistent in commercial practice. The results suggest that the benefits of argon enrichment may be relatively small, and may require critical enzyme, substrate, and gas levels to be successful. However, these benefits may be exploitable commercially in some fresh-cut products, and allow less anoxic atmospheres to be used.

  7. Surface activation of polyethylene with an argon atmospheric pressure plasma jet: Influence of applied power and flow rate

    Science.gov (United States)

    Van Deynse, A.; Cools, P.; Leys, C.; De Geyter, N.; Morent, R.

    2015-02-01

    Atmospheric pressure plasma technology offers attractive perspectives to alter the surface properties of polymers. Within this context, the surface modification of polyethylene (LDPE) by an argon atmospheric pressure plasma jet (APPJ) is profoundly investigated in this work. The influence of two different parameters (applied power and argon flow rate) on the plasma jet characteristics and the LDPE surface properties is examined in detail. In a first step, the APPJ is electrically and visually characterized and visual inspection of the afterglow clearly shows that mainly a variation in argon flow rate can result in a changing afterglow length. A maximum afterglow length is obtained at an argon flow rate of 1-1.25 slm, while higher gas flows result in turbulence leading to a shorter afterglow. Secondly, the surface modification of LDPE is examined using different analyzing techniques namely water contact angle (WCA) measurements for the wettability, X-ray photoelectron spectroscopy (XPS) for the chemical composition and atomic force microscopy (AFM) for the surface morphology determination. WCA measurements show that by increasing the applied power the wettability of the LDPE increases. Increasing the argon flow rate up to 1.25 slm gives a decrease in WCA value or in other words an increased wettability. From 1.25 slm on, an increase in argon flow rate during plasma treatment decreases the LDPE wettability as can be concluded from the increased WCA values. An increased wettability can be explained by the incorporation of oxygen moieties. By increasing the discharge power, the concentrations of all oxygen containing groups such as Csbnd O, Cdbnd O and Osbnd Cdbnd O increase. Increasing the flow rate up to 1.25 slm results mainly in an increase in Osbnd Cdbnd O groups. However, from a flow rate of 1.25 slm on, the concentration of all oxygen groups again decreases. Based on these results, the appropriate settings for an efficient plasma treatment can easily be selected.

  8. A new concept of y-ray telescope. LArGO: Liquid Argon Gamma-ray Observatory

    OpenAIRE

    Caliandro, Giuseppe Andrea; Rossi, Biagio; Longo, Francesco; Fiorillo, Giuliana; Labanti, Claudio; Sanchez, Federico; Lux, Thorsten

    2013-01-01

    LArGO (Liquid Argon Gamma-ray Observatory) consists of a new design for a $\\gamma$-ray telescope, which exploits the idea of using a Liquid Argon Time Projection Chamber (LAr-TPC) as tracker-converter. Particle tracking in LAr-TPC can efficiently starts since the primary photon vertex. Indeed, while in the present space telescopes the incident photon converts in a tungsten foil, which is a passive material, in a LAr-TPC this conversion happens in LAr itself, which is fully active. In this pro...

  9. Surface activation of polyethylene with an argon atmospheric pressure plasma jet: Influence of applied power and flow rate

    Energy Technology Data Exchange (ETDEWEB)

    Van Deynse, A., E-mail: Annick.VanDeynse@ugent.be [Department Industrial Technology and Construction, Faculty of Engineering & Architecture, Ghent University, Valentin Vaerwyckweg 1, 9000 Ghent (Belgium); Cools, P., E-mail: Pieter.Cools@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); Leys, C., E-mail: Christophe.Leys@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); De Geyter, N., E-mail: Nathalie.DeGeyter@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium); Morent, R., E-mail: Rino.Morent@ugent.be [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering & Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000 Ghent (Belgium)

    2015-02-15

    Highlights: • Surface modification of polyethylene by an argon atmospheric pressure plasma jet. • Investigation of the influence of the applied power and argon flow rate. • Turbulence in the gas flow leads to a shorter afterglow. • Turbulence in the gas flow results in a lower wettability of the polyethylene. • Increasing the applied power increases the wettability of the polyethylene. - Abstract: Atmospheric pressure plasma technology offers attractive perspectives to alter the surface properties of polymers. Within this context, the surface modification of polyethylene (LDPE) by an argon atmospheric pressure plasma jet (APPJ) is profoundly investigated in this work. The influence of two different parameters (applied power and argon flow rate) on the plasma jet characteristics and the LDPE surface properties is examined in detail. In a first step, the APPJ is electrically and visually characterized and visual inspection of the afterglow clearly shows that mainly a variation in argon flow rate can result in a changing afterglow length. A maximum afterglow length is obtained at an argon flow rate of 1–1.25 slm, while higher gas flows result in turbulence leading to a shorter afterglow. Secondly, the surface modification of LDPE is examined using different analyzing techniques namely water contact angle (WCA) measurements for the wettability, X-ray photoelectron spectroscopy (XPS) for the chemical composition and atomic force microscopy (AFM) for the surface morphology determination. WCA measurements show that by increasing the applied power the wettability of the LDPE increases. Increasing the argon flow rate up to 1.25 slm gives a decrease in WCA value or in other words an increased wettability. From 1.25 slm on, an increase in argon flow rate during plasma treatment decreases the LDPE wettability as can be concluded from the increased WCA values. An increased wettability can be explained by the incorporation of oxygen moieties. By increasing the

  10. Development of an anti-Compton veto for HPGe detectors operated in liquid argon using Silicon Photo-Multipliers

    CERN Document Server

    Janicskó-Csáthy, József; Liu, Xiang; Majorovits, Béla; Caldwell, Allen

    2010-01-01

    A proof of concept detector is presented for scintillation light detection in liquid argon using Silicon Photo-Multipliers. The aim of the work is to build an anti-Compton veto for germanium detectors operated directly in liquid argon like in the GERDA experiment. Properties of the Multi-Pixel Photon Counter (MPPC) are studied at cryogenic temperatures. To increase the light collection efficiency of the MPPCs wavelength shifting fibers were used. A veto efficiency comparable to a similar setup with a Photo-Multiplier Tube was achieved.

  11. Surface activation of polyethylene with an argon atmospheric pressure plasma jet: Influence of applied power and flow rate

    International Nuclear Information System (INIS)

    Highlights: • Surface modification of polyethylene by an argon atmospheric pressure plasma jet. • Investigation of the influence of the applied power and argon flow rate. • Turbulence in the gas flow leads to a shorter afterglow. • Turbulence in the gas flow results in a lower wettability of the polyethylene. • Increasing the applied power increases the wettability of the polyethylene. - Abstract: Atmospheric pressure plasma technology offers attractive perspectives to alter the surface properties of polymers. Within this context, the surface modification of polyethylene (LDPE) by an argon atmospheric pressure plasma jet (APPJ) is profoundly investigated in this work. The influence of two different parameters (applied power and argon flow rate) on the plasma jet characteristics and the LDPE surface properties is examined in detail. In a first step, the APPJ is electrically and visually characterized and visual inspection of the afterglow clearly shows that mainly a variation in argon flow rate can result in a changing afterglow length. A maximum afterglow length is obtained at an argon flow rate of 1–1.25 slm, while higher gas flows result in turbulence leading to a shorter afterglow. Secondly, the surface modification of LDPE is examined using different analyzing techniques namely water contact angle (WCA) measurements for the wettability, X-ray photoelectron spectroscopy (XPS) for the chemical composition and atomic force microscopy (AFM) for the surface morphology determination. WCA measurements show that by increasing the applied power the wettability of the LDPE increases. Increasing the argon flow rate up to 1.25 slm gives a decrease in WCA value or in other words an increased wettability. From 1.25 slm on, an increase in argon flow rate during plasma treatment decreases the LDPE wettability as can be concluded from the increased WCA values. An increased wettability can be explained by the incorporation of oxygen moieties. By increasing the

  12. Theoretical calculation of triple differential cross sections of 3s orbital of argon in coplanar symmetric (e, 2e) reaction

    Institute of Scientific and Technical Information of China (English)

    Wu Xing-Ju; Chen Xiang-Jun; Shan Xu; Chen Li-Qing; Xu Ke-Zun

    2004-01-01

    The triple differential cross section for the low-energy electron impact ionization of inner-valence 3s orbital of argon has been calculated using the modified distorted wave Born approximation in coplanar symmetric energy-sharing geometry. Satisfactory agreement between theory and experiment is achieved when the polarization and post-collisional interaction (PCI) are included in the calculations. It is shown that the polarization and PCI effects play a very important role in the case of argon at low incident energies.

  13. Status of the ArDM Experiment: First results from gaseous argon operation in deep underground environment

    CERN Document Server

    Badertscher, A; Bourgeois, N; Cantini, C; Daniel, M; Degunda, U; DiLuise, S; Epprecht, L; Gendotti, A; Horikawa, S; Knecht, L; Lussi, D; Maire, G; Montes, B; Murphy, S; Natterer, G; Nikolics, K; Nguyen, K; Periale, L; Ravat, S; Resnati, F; Romero, L; Rubbia, A; Santorelli, R; Sergiampietri, F; Sgalaberna, D; Viant, T; Wu, S

    2013-01-01

    The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper, we describe the status of the installation and present first results on data collected in gas phase.

  14. Morphology and characteristics of laser-induced aluminum plasma in argon and in air: A comparative study

    Science.gov (United States)

    Bai, Xueshi; Cao, Fan; Motto-Ros, Vincent; Ma, Qianli; Chen, Yanping; Yu, Jin

    2015-11-01

    In laser-induced breakdown spectroscopy (LIBS), ablation takes place in general in an ambient gas of the atmospheric pressure, often in air but also in noble gas such as argon or helium. The use of noble gas is known to significantly improve the performance of the technique. We investigate in this work the morphology and the characteristics of induced plasma in argon and in air. The purpose is to understand the mechanism of the analytical performance improvement by the use of argon ambient with respective to air ambient and the dependence on the other experimental parameters such as the laser fluence. The observation of plasma morphology in different ambient gases provides also information for better design of the detection system which optimizes the signal collection according to the used ambient gases. More specifically, the expansion of the plasma induced on an aluminum target with nanosecond infrared (1064 nm) laser pulse in two ambient gases, argon and the atmospheric air, has been studied with spectroscopic imaging at short delays and with emission spectroscopy at longer delays. With relatively low ablation laser fluence (65 J/cm2), similar morphologies have been observed in argon and in air over the early stage of plasma expansion, while diagnostics at longer delay shows stronger emission, higher electron density and temperature for plasma induced in argon. With higher ablation laser fluence (160 J/cm2) however, different expansion behaviors have been observed, with a stagnating aluminum vapor near the target surface in air while a propagating plume away from the target in argon. The craters left on the target surface show as well corresponding difference: in air, the crater is very shallow with a target surface chaotically affected by the laser pulse, indicating an effective re-deposition of the ablated material back to the crater; while in Ar a deeper crater is observed, indicating an efficient mass removal by laser ablation. At longer delays, a brighter

  15. Enhanced Field Emission from Argon Plasma-Treated Ultra-sharp α-Fe2O3Nanoflakes

    Directory of Open Access Journals (Sweden)

    Zhang JX

    2009-01-01

    Full Text Available Abstract Hematite nanoflakes have been synthesized by a simple heat oxide method and further treated by Argon plasmas. The effects of Argon plasma on the morphology and crystal structures of nanoflakes were investigated. Significant enhancement of field-induced electron emission from the plasma-treated nanoflakes was observed. The transmission electron microscopy investigation shows that the plasma treatment effectively removes amorphous coating and creates plenty of sub-tips at the surface of the nanoflakes, which are believed to contribute the enhancement of emission. This work suggests that plasma treatment technique could be a direct means to improve field-emission properties of nanostructures.

  16. Argon protects against hypoxic-ischemic brain injury in neonatal rats through activation of nuclear factor (erythroid-derived 2)-like 2

    Science.gov (United States)

    Zhao, Hailin; Mitchell, Sian; Ciechanowicz, Sarah; Savage, Sinead; Wang, Tianlong; Ji, Xunming; Ma, Daqing

    2016-01-01

    Perinatal hypoxic ischaemic encephalopathy (HIE) has a high mortality rate with neuropsychological impairment. This study investigated the neuroprotective effects of argon against neonatal hypoxic-ischaemic brain injury. In vitro cortical neuronal cell cultures derived from rat foetuses were subjected to an oxygen and glucose deprivation (OGD) challenge for 90 minutes and then exposed to 70% argon or nitrogen with 5% carbon dioxide and balanced with oxygen for 2 hours. In vivo, seven-day-old rats were subjected to unilateral common carotid artery ligation followed by hypoxic (8% oxygen balanced with nitrogen) insult for 90 minutes. They were exposed to 70% argon or nitrogen balanced with oxygen for 2 hours. In vitro, argon treatment of cortical neuronal cultures resulted in a significant increase of p-mTOR and Nuclear factor (erythroid-derived 2)-like 2(Nrf2) and protection against OGD challenge. Inhibition of m-TOR through Rapamycin or Nrf2 through siRNA abolished argon-mediated cyto-protection. In vivo, argon exposure significantly enhanced Nrf2 and its down-stream effector NAD(P)H Dehydrogenase, Quinone 1(NQO1) and superoxide dismutase 1(SOD1). Oxidative stress, neuroinflammation and neuronal cell death were significantly decreased and brain infarction was markedly reduced. Blocking PI-3K through wortmannin or ERK1/2 through U0126 attenuated argon-mediated neuroprotection. These data provide a new molecular mechanism for the potential application of argon as a neuroprotectant in HIE. PMID:27016422

  17. Geochemistry on mantle-derived volatiles in natural gases from eastern China oil/gas provinces (I )——Helium, argon and hydrocarbons in mantle volatiles

    Institute of Scientific and Technical Information of China (English)

    徐永昌; 沈平; 陶明信; 刘文汇

    1997-01-01

    Researches on helium, argon, carbon dioxide and methane are very significant in studies of mantle substance characteristics and mantle evolution. A < -shaped pattern of the isotope composition distribution of helium and argon sourced from the mantle and the crust, abundance distribution, isotopic composition and reservoir formation of carbon dioxide, and mantle-sourced methane are discussed.

  18. Experimental behaviour of a argon plasma, which is passed by a high current intensity, with different magnetic field configurations; Comportamiento experimental de un plasma de argon en diferentes configuraciones de campo magnetico y a elevadas corrientes

    Energy Technology Data Exchange (ETDEWEB)

    Lozano, J.

    1964-07-01

    In a lineal discharge, the longitudinal and azimuthal magnetic fields produced by the current through the tube and the returning conductors, which have 4 different forms, are determined with a magnetic probe, which has a radial and longitudinal displacement. The plasma is produced discharging a 135{mu}F and 9 KV capacitor bank through Argon at 10{sup -}1 Torr. (Author) 5 refs.

  19. Investigating the Mutagenicity of a Cold Argon-Plasma Jet in an HET-MN Model

    Science.gov (United States)

    Bender, Claudia; Benkhai, Hicham; Sckell, Axel; Below, Harald; Stope, Matthias B.; Kramer, Axel

    2016-01-01

    Objective So-called cold physical plasmas for biomedical applications generate reactive oxygen and nitrogen species and the latter can trigger DNA damage at high concentrations. Therefore, the mutagenic risks of a certified atmospheric pressure argon plasma jet (kINPen MED) and its predecessor model (kINPen 09) were assessed. Methods Inner egg membranes of fertilized chicken eggs received a single treatment with either the kINPen 09 (1.5, 2.0, or 2.5 min) or the kINPen MED (3, 4, 5, or 10 min). After three days of incubation, blood smears (panoptic May-Grünwald-Giemsa stain) were performed, and 1000 erythrocytes per egg were evaluated for the presence of polychromatic and normochromic nuclear staining as well as nuclear aberrations and binucleated cells (hen’s egg test for micronuclei induction, HET-MN). At the same time, the embryo mortality was documented. For each experiment, positive controls (cyclophosphamide and methotrexate) and negative controls (NaCl-solution, argon gas) were included. Additionally, the antioxidant potential of the blood plasma was assessed by ascorbic acid oxidation assay after treatment. Results For both plasma sources, there was no evidence of genotoxicity, although at the longest plasma exposure time of 10 min the mortality of the embryos exceeded 40%. The antioxidant potential in the egg’s blood plasma was not significantly reduced immediately (p = 0.32) or 1 h (p = 0.19) post exposure to cold plasma. Conclusion The longest plasma treatment time with the kINPen MED was 5–10 fold above the recommended limit for treatment of chronic wounds in clinics. We did not find mutagenic effects for any plasma treatment time using the either kINPen 09 or kINPen MED. The data provided with the current study seem to confirm the lack of a genotoxic potential suggesting that a veterinary or clinical application of these argon plasma jets does not pose mutagenic risks. PMID:27584003

  20. Toward Improvements in Inter-laboratory Calibration of Argon Isotope Measurements

    Science.gov (United States)

    Hemming, S. R.; Deino, A. L.; Heizler, M. T.; Hodges, K. V.; McIntosh, W. C.; Renne, P. R.; Swisher, C. C., III; Turrin, B. D.; Van Soest, M. C.

    2015-12-01

    It is important to continue to develop strategies to improve our ability to compare results between laboratories chronometers. The U-Pb community has significantly reduced inter-laboratory biases with the application of a community tracer solution and the distribution of synthetic zircon solutions. Inevitably sample selection and processing and even biases in interpretations will still lead to some disagreements in the assignment of ages. Accordingly natural samples that are shared will be important for achievement of the highest levels of agreement. Analogous improvements in quality and inter-laboratory agreement of analytical aspects of Ar-Ar can be achieved through development of synthetic age standards in gas canisters with multiple pipettes to deliver various controlled amounts of argon to the mass spectrometer. A preliminary proof-of concept comes from the inter-laboratory calibration experiment for the 40Ar/39Ar community. This portable Argon Pipette Intercalibration System (APIS) consists of three 2.7 L canisters each equipped with three pipettes of 0.1, 0.2 and 0.4 cc volumes. The currently traveling APIS has the three canisters filled with air and 40Ar*/39Ar of 1.73 and canister 2 has a 40Ar*/39Ar of 40.98 (~ Alder Creek and Fish Canyon in the same irradiation). With these pipettes it is possible to combine them to provide 0.1, 0.2, 0.3 (0.1+0.2), 0.4, 0.5 (0.1+0.4), 0.6 (0.2+0.4), and 0.7 (0.1+0.2+0.4) cc. The configuration allows a simple test for inter-laboratory biases and for volume/pressure dependent mass fractionation on the measured ratios for a gas with a single argon isotope composition. Although not yet tested, it is also possible to mix gas from any one of the three canisters in proportions of these increments, allowing even more tightly controlled calibration of measurements. We suggest that ultimately each EARTHTIME lab should be equipped with such a system permanently, with a community plan for a traveling system to periodically repeat the

  1. Electronic relaxation dynamics of a metal atom deposited on argon cluster

    International Nuclear Information System (INIS)

    This thesis is a study on the interaction between electronically excited atomic states and a non-reactive environment. We have theoretically and experimentally studied situations where a metal atom (Ba or K) is placed in a finite size environment (argon cluster). The presence of the medium affects the electronic levels of the atom. On the other side, the excitation of the atom induces a relaxation dynamics of the electronic energy through the deformation of the cluster. The experimental part of this work focuses on two aspects: the spectroscopy and the dynamics. In both cases a first laser electronically excites the metal atom and the second ionizes the excited system. The observable is the photoelectron spectrum recorded after photoionization and possibly information on the photoion which are also produced. This pump/probe technique, with also two lasers, provide the ultrafast dynamic when the lasers pulses used are of ultrashort (60 fs). The use of nanosecond lasers leads to resonance spectroscopic measurement, unresolved temporally, which give information on the position of the energy levels of the studied system. From a theoretical point-of-view, the excited states of M-Arn were calculated at the ab initio level, using large core pseudo-potential to limit the active electrons of the metal to valence electrons. The study of alkali metals (potassium) is especially well adapted to this method since only one electron is active. The ab-initio calculation and a Monte-Carlo simulation where coupled to optimize the geometry of the KArn (n = 1-10) cluster when K is in the ground state of the neutral and the ion, or excited in the 4p or 5s state. Calculations were also conducted in collaboration with B. Gervais (CIMAP, Caen) on KArn clusters having several tens of argon atoms. Absorption spectra were also calculated. From an experimental point-of-view, we were able to characterize the excited states of potassium and barium perturbed by the clusters. In both cases a

  2. Heart rate variability of human in hypoxic oxygen-argon environment

    Science.gov (United States)

    Khayrullina, Rezeda; Smoleevskiy, Alexandr; Bubeev, Yuri

    Human adaptive capacity, reliability and stability in extreme environments depend primarily on the individual resistance to stresses, includes both innate and acquired components. We have conducted studies in six healthy subjects - men aged between 24 to 42 years who psychophysiological indicators acterizing the severity of stress reactions studied directly during an emergency situation, before and after it. The subjects were in a hypoxic oxygen-argon atmosphere 10 days. Cardiovascular system is one of the first to respond to stressful reaction. The method of heart rate variability (HRV) allows us to estimate balance of sympathetic and parasympathetic parts of vegetative nervous system. In the course of the baseline study it was found that resting heart rate (HR) in the examined individuals is within normal limits. During the experiment in all subjects there was a trend towards more frequent heartbeat. Each subject at one stage or another stay in a hypoxic oxygen-argon environment heart rate go beyond the group norm, but the extent and duration of these abnormalities were significantly different. Marked increase in middle heart rate during of subjects experiment, fluctuating within a wide range (from 2.3% to 29.1%). Marked increase in middle heart rate during of subjects experiment, fluctuating within a wide range (from 2.3% to 29.1%). This suggests that the ability to adapt to living in the investigated gas environment have marked individual differences. SDNN (mean square deviation of all R-R intervals) is the integral indicator of the total effect of the sinus node to the sympathetic and parasympathetic parts of vegetative nervous system, as well as indicating the higher functional reserves of the cardiovascular systems. Increase in heart rate in the majority of subject was accompanied by an increase in individual SDNN. This suggests that the parasympathetic system is able to balance the increase in activity of the sympathetic system, and functional reserves are

  3. A method to suppress dielectric breakdowns in liquid argon ionization detectors for cathode to ground distances of several millimeters

    OpenAIRE

    Auger, Martin; Ereditato, Antonio; Göldi, Damian; Janos, Stefan; Kreslo, Igor; Lüthi, Matthias; Rudolf von Rohr, Christoph; Strauss, Thomas; Tolba, Tamer; Weber, Michael

    2014-01-01

    We present a method to reach electric field intensity as high as 400 kV/cm in liquid argon for cathode-ground distances of several millimeters. This can be achieved by suppressing field emission from the cathode, overcoming limitations that we reported earlier.

  4. Infrared spectra and electronic structure calculations for NN complexes with U, UN, and NUN in solid argon, neon, and nitrogen.

    Science.gov (United States)

    Andrews, Lester; Wang, Xuefeng; Gong, Yu; Kushto, Gary P; Vlaisavljevich, Bess; Gagliardi, Laura

    2014-07-17

    Reactions of laser-ablated U atoms with N2 molecules upon codeposition in excess argon or neon at 4 K gave intense NUN and weak UN absorptions. Annealing produced progressions of new absorptions for the UN2(N2)1,2,3,4,5 and UN(N2)1,2,3,4,5,6 complexes. The neon-to-argon matrix shift decreases with increasing NN ligation and therefore the number of noble gas atoms left in the primary coordination sphere around the NUN molecule. Small matrix shifts are observed when the secondary coordination layers around the primary UN2(N2)1,2,3,4,5 and UN(N2)1,2,3,4,5,6 complexes are changed from neon-to-argon to nitrogen. Electronic structure, energy, and frequency calculations provide support for the identification of these complexes and the characterization of the N≡U≡N and U≡N core molecules as terminal uranium nitrides. Codeposition of U with pure nitrogen produced the saturated U(NN)7 complex, which UV irradiation converted to the NUN(NN)5 complex with slightly lower frequencies than found in solid argon.

  5. Introduction of sulfate groups on poly(ethylene) surfaces by argon plasma immobilization of sodium alkyl sulfates

    NARCIS (Netherlands)

    Lens, J.P.; Terlingen, J.G.A.; Engbers, G.H.M.; Feijen, J.

    1998-01-01

    Sulfate groups were introduced at the surface of poly(ethylene) (PE) samples. This was accomplished by immobilizing a precoated layer of either sodium 10-undecene sulfate (S11(:)) or sodium dodecane sulfate (SDS) on the polymeric surface by means of an argon plasma treatment. For this purpose, S11(:

  6. On the effect of treating poly(acrylic acid) with argon and tetrafluoromethane plasmas: Kinetics and degradation mechanism

    NARCIS (Netherlands)

    Terlingen, Johannes G.A.; Takens, Gijsbert A.J.; Gaag, van der Frederik J.; Hoffman, Allan S.; Feijen, Jan

    1994-01-01

    Poly(acrylic acid) (PAAc) films were treated with either an argon or a tetrafluoromethane (CF4) plasma and subsequently analyzed with X-ray photoelectron spectroscopy (XPS). PAAc films were decarboxylated during both types of plasma treatments. In addition, during the CF4 plasma treatment, the PAAc

  7. Hybrid modeling of a capacitively coupled radio frequency glow discharge in argon: Combined Monte Carlo and fluid model

    NARCIS (Netherlands)

    Bogaerts, A.; Gijbels, R.; W. Goedheer,

    1999-01-01

    A hybrid model has been developed for a capacitively coupled rf glow discharge in argon, employed as a spectroscopic source in the field of analytical chemistry. The cell is a rather small cylinder with a very small rf-powered electrode (only 5 mm in diameter). The typical working conditions applied

  8. Comparison between integral equation method and molecular dynamics simulation for three-body forces: Application to supercritical argon

    NARCIS (Netherlands)

    Bomont, Jean-Marc; Bretonnet, Jean-Louis; Hoef, van der Martin A.

    2001-01-01

    The prediction of the structural and thermodynamic properties of supercritical argon has been carried out by two independent routes: semianalytical calculations and numerical simulations. The first one is based on the hybridized mean spherical approximation (HMSA) conjugated with an effective pair p

  9. The influence of the EUV spectrum on plasma induced by EUV radiation in argon and hydrogen gas

    Science.gov (United States)

    van der Horst, R. M.; Osorio, E. A.; Banine, V. Y.; Beckers, J.

    2016-02-01

    Plasmas induced by EUV radiation are scarcely investigated, although they are unique since they are created without any discharge. These plasmas are also of interest from an applicational point of view, since they are related to the lifetime of optics in EUV lithography tools. In order to assess this impact, it is essential to characterize and understand EUV-induced plasma. In this contribution the influence of the background gas (argon and hydrogen) in the lithography tool and the spectrum of the illumination source on the electron density of EUV-induced plasma is investigated using microwave cavity resonance spectroscopy. The experimental results showed that out-of-band radiation (>20 nm) is the main contributor to EUV-induced plasma in both argon and hydrogen. In hydrogen, this contribution is relatively more important than in argon due to the stronger wavelength dependence of the photoionization cross section of hydrogen than of argon. Furthermore, the production of electrons by out-of-band radiation lasts longer than the production by in-band radiation (10-20 nm) due to the longer temporal width of out-of-band radiation. Finally, the obtained results correspond reasonably well with estimates from a simplified absorption model.

  10. An allene-doped liquid argon ionization chamber for Ar and Ca ions at around 100 MeV/n

    CERN Document Server

    Yunoki, A; Fukuda, N; Kase, M; Kato, T; Kikuchi, J; Masuda, K; Niimura, M; Okada, H; Ozaki, K; Piao, Y; Shibamura, E; Tanaka, M; Tanihata, I; Terasawa, K

    1999-01-01

    An allene-doped liquid argon ionization chamber with 48 mmx48 mmx40 mm sensitive volume has been constructed for precise energy measurement of heavy ions at around 100 MeV/n. An energy resolution of 0.6%-0.7% (FWHM) was achieved for Ca and Ar ions both at 78 MeV/n. (author)

  11. The Relationship between Balancing Reactions and Reaction Lifetimes: A Consideration of the Potassium-Argon Radiometric Method for Dating Minerals

    Science.gov (United States)

    Howard, William A.

    2005-01-01

    A detailed examination of a commonly accepted practice in geology offers an example of how to stimulate critical thinking, teaches students how to read reactions, and challenges students to formulate better experiments for determining mineral ages more accurately. A demonstration of a Potassium-Argon radiometric method for dating minerals is…

  12. In vitro and in vivo microbial adhesion and growth on argon plasma-treated silicone rubber voice prostheses

    NARCIS (Netherlands)

    Everaert, EPJM; Van de Belt-Gritter, B; Van der Mei, HC; Busscher, HJ; Verkerke, GJ; Dijk, F; Mahieu, HF; Reitsma, A

    1998-01-01

    Patients who undergo a total laryngectomy usually receive a silicone rubber voice prosthesis for voice rehabilitation. Unfortunately, biofilm formation on the esophageal side of voice prostheses limits their lifetime to 3-4 mon on average. The effects of repeated argon plasma treatment of medical gr

  13. Giant Liquid Argon Observatory for Proton Decay, Neutrino Astrophysics and CP-violation in the Lepton Sector (GLACIER)

    CERN Document Server

    Badertscher, A; Degunda, U; Epprecht, L; Horikawa, S; Knecht, L; Lazzaro, C; Lussi, D; Marchionni, A; Natterer, G; Otiougova, P; Resnati, F; Rubbia, A; Strabel, C; Ulbricht, J; Viant, T

    2010-01-01

    GLACIER (Giant Liquid Argon Charge Imaging ExpeRiment) is a large underground observatory for proton decay search, neutrino astrophysics and CP-violation studies in the lepton sector. Possible underground sites are studied within the FP7 LAGUNA project (Europe) and along the JPARC neutrino beam in collaboration with KEK (Japan). The concept is scalable to very large masses.

  14. Structural and Thermodynamic Properties of the Argon Dimer: A Computational Chemistry Exercise in Quantum and Statistical Mechanics

    Science.gov (United States)

    Halpern, Arthur M.

    2010-01-01

    Using readily available computational applications and resources, students can construct a high-level ab initio potential energy surface (PES) for the argon dimer. From this information, they can obtain detailed molecular constants of the dimer, including its dissociation energy, which compare well with experimental determinations. Using both…

  15. Possible wave formation and martensitic transformation of iron particles in copper single crystals during argon ion bombardment

    DEFF Research Database (Denmark)

    Thölén, Anders Ragnar; Li, Chang-Hai; Easterling, K.E.

    1983-01-01

    Thin single crystal copper specimens (thickness ~250 nm) containing coherent iron particles (diameter 40–50 nm) have been bombarded with argon ions (5, 80, and 330 keV). During this process some of the iron particles transform to martensite. The transformation was observed near the exposed surface...

  16. Performance and emission characteristics of the thermal barrier coated SI engine by adding argon inert gas to intake mixture

    Directory of Open Access Journals (Sweden)

    T. Karthikeya Sharma

    2015-11-01

    Full Text Available Dilution of the intake air of the SI engine with the inert gases is one of the emission control techniques like exhaust gas recirculation, water injection into combustion chamber and cyclic variability, without scarifying power output and/or thermal efficiency (TE. This paper investigates the effects of using argon (Ar gas to mitigate the spark ignition engine intake air to enhance the performance and cut down the emissions mainly nitrogen oxides. The input variables of this study include the compression ratio, stroke length, and engine speed and argon concentration. Output parameters like TE, volumetric efficiency, heat release rates, brake power, exhaust gas temperature and emissions of NOx, CO2 and CO were studied in a thermal barrier coated SI engine, under variable argon concentrations. Results of this study showed that the inclusion of Argon to the input air of the thermal barrier coated SI engine has significantly improved the emission characteristics and engine’s performance within the range studied.

  17. Study of Thermal Conductivity of Hydrogen-argon Mixture at Different Temperatures for Thermal Insulation Pipes in Petroleum Industry

    Institute of Scientific and Technical Information of China (English)

    ZHOU Cheng-long; XU Yong-xiang; SHENG Hong-zhi

    2014-01-01

    In this paper, through the study of thermal conductivity of hydrogen- argon mixture at different temperatures for thermal insulation pipes in petroleum industry, a good method for determining the thermal conductivity of other gas mixture at different temperatures has been provided.

  18. The ATLAS liquid argon calorimeter high-voltage system: commissioning, optimisation and LHC relative luminosity measurement

    International Nuclear Information System (INIS)

    The main goals of the ATLAS scientific programme are the observation or exclusion of physics beyond the Standard Model (SM), as well as the measurement of production cross-sections of SM processes. In order to do so, it is important to measure the luminosity at the interaction point with great precision. The ATLAS luminosity is extracted using several detectors with varying efficiencies and acceptances. Different methods, such as inclusive - or coincidence - event counting and calorimeter integrated current measurements, are calibrated and cross-compared to provide the most accurate luminosity determination. In order to provide more cross-checks and a better control on the systematic uncertainties, an independent measurement using the liquid argon (LAr) forward calorimeter (FCal), based on the readout current of its high-voltage system, has been developed. This document describes how the LAr calorimeter high-voltage system has been installed and commissioned, as well as its application to a relative luminosity determination. (author)

  19. Measurements of ion mobility in argon and neon based gas mixtures

    CERN Document Server

    Deisting, Alexander; Szabo, Alexander; Vranic, Danilo

    2016-01-01

    As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run$\\,3$ with a substantial space charge density of positive ions in the drift volume. In order to properly simulate such space charges, knowledge of the ion mobility $K$ is necessary. To this end, a small gaseous detector was constructed and the ion mobility of various gas mixtures was measured. To validate the corresponding signal analysis, simulations were performed. Results are shown for several argon and neon based mixtures with different $\\textrm{CO}_2$ fractions. A decrease of $K$ was measured for increasing water content.

  20. Some metals determination in beers by atomic emission spectrometry of induced argon plasma

    International Nuclear Information System (INIS)

    It was made the identification and determination of metals in brazilian bottled and canned beer, using atomic emission spectrometry with d.c. are and argon coupled plasma excitation sources. The elements Co, Cr, Cu, Fe, Pb and Zn were determined in beer samples, after treatment with HNO sub(3) conc. /H sub(2) O sub(2) (30%). In the determination of Co, Cr, Cu, Pb and Zn and alternative method using HNO sub(3) conc. /O sub(3) was proved be useful. The results obtained for Co, Cr, Cu, Fe, Pb and Zn were below the limits established by brazilian legislation, showing the good quality of the beer concerning the metals. The results of this work were requested by the previous Ministerio do Meio Ambiente e Urbanismo in order to contribute to review the brazilian legislation in foods and beverages about metals contents. (author)