WorldWideScience

Sample records for argon chlorides

  1. Uranium (III) precipitation in molten chloride by wet argon sparging

    Science.gov (United States)

    Vigier, Jean-François; Laplace, Annabelle; Renard, Catherine; Miguirditchian, Manuel; Abraham, Francis

    2016-06-01

    In the context of pyrochemical processes for nuclear fuel treatment, the precipitation of uranium (III) in molten salt LiCl-CaCl2 (30-70 mol%) at 705 °C is studied. First, this molten chloride is characterized with the determination of the water dissociation constant. With a value of 10-4.0, the salt has oxoacid properties. Then, the uranium (III) precipitation using wet argon sparging is studied. The salt is prepared using UCl3 precursor. At the end of the precipitation, the salt is totally free of solubilized uranium. The main part is converted into UO2 powder but some uranium is lost during the process due to the volatility of uranium chloride. The main impurity of the resulting powder is calcium. The consequences of oxidative and reductive conditions on precipitation are studied. Finally, coprecipitation of uranium (III) and neodymium (III) is studied, showing a higher sensitivity of uranium (III) than neodymium (III) to precipitation.

  2. Surface modification of poly (vinyl chloride) by long-distance and direct argon RF plasma

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper reports the effects of long- distance and direct argon radio frequency (RF) plasma surface treatment on polyvinyl chloride (PVC) films in terms of changes in surface wettability and surface chemistry. The surface properties are characterized by the water contact angle measurement, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The mechanism is further analyzed and the role of all kinds of active species, e.g. electrons, ions and free radicals involved in plasma surface modification is further evaluated. Results show that the long-distance and direct RF plasma treatments modify the PVC surface in morphology and composition, and both modifications cause surface oxidation of PVC films, in the forming of functional groups enhancing polymer wettability. The effect of the long-distance argon RF plasma is more notable. This suggests that long-distance argon RF plasma could restrain the ion and electron eroding effect and enhance free radical reaction.

  3. Sulphate analysis in uranium leach iron(III) chloride solutions by inductively coupled argon plasma spectrometry

    International Nuclear Information System (INIS)

    Inductively coupled Argon Plasma Spectrometry is used for the indirect determination of sulphate in iron(III) chloride leach solution of Elliot Lake uranium ores via addition of a known amount of barium ions and analyzing for excess of barium. The ore contains ∼ 7 wt% pyrite, FeS2, as the major mineral which oxidizes to generate sulphate during leaching with Fe(III). The effects of pH, the concentrations of Fe(III) and chloride ions and for presence of ethanol in the test samples on the accuracy of analysis are studied. It is found that unlike the Rhodizonate method, removal of iron(III) from or addition of ethanol to the test sample prior to analysis are not required. Linear calibration curves are obtained. (author)

  4. Surface Modification of Poly Vinyl Chloride (PVC) Using Low Pressure Argon and Oxygen Plasma

    International Nuclear Information System (INIS)

    In this study, commercial poly vinyl chloride (PVC) films were treated by oxygen and argon plasmas in a cylindrical glass tube which was surrounded by a DC variable magnetic field, with different sample positions in the plasma reactor and also different exposure durations. Effects of the plasma treatment on the hydrophilic properties of the films were studied by measuring the water drop contact angle on the surface of the samples. The surface topography of the untreated and plasma treated films was analyzed and compared by atomic force microscopy (AFM). The optical characteristic changes in treated samples were investigated using reflective spectrophotometry. Also, the chemical changes which appeared on the surface of the samples were investigated using Fourier transform infrared spectroscopy (FTIR). The results show that the plasma treated PVC becomes more hydrophilic with an enhanced wettability. A sharp decrease in the water contact angle may also be a consequence of the surface texturization. The aging effect on wettability of the samples was also investigated. The results show that the effect of oxygen plasma on the surface properties of the samples is more pronounced compared with that of argon plasma.

  5. Argon plasma coagulation

    Directory of Open Access Journals (Sweden)

    Zenker, Matthias

    2008-03-01

    Full Text Available Argon Plasma Coagulation (APC is an application of gas discharges in argon in electrosurgery, which is increasingly used especially in endoscopy. The major application fields are haemostasis, tissue devitalization and tissue reduction.This review describes the physics and technology of electrosurgery and APC. Some characteristics of the argon discharge are shown and discussed, and thermal effects in biological tissue are described. Subsequently, examples of medical applications are given.

  6. Lunar exospheric argon modeling

    Science.gov (United States)

    Grava, Cesare; Chaufray, J.-Y.; Retherford, K. D.; Gladstone, G. R.; Greathouse, T. K.; Hurley, D. M.; Hodges, R. R.; Bayless, A. J.; Cook, J. C.; Stern, S. A.

    2015-07-01

    Argon is one of the few known constituents of the lunar exosphere. The surface-based mass spectrometer Lunar Atmosphere Composition Experiment (LACE) deployed during the Apollo 17 mission first detected argon, and its study is among the subjects of the Lunar Reconnaissance Orbiter (LRO) Lyman Alpha Mapping Project (LAMP) and Lunar Atmospheric and Dust Environment Explorer (LADEE) mission investigations. We performed a detailed Monte Carlo simulation of neutral atomic argon that we use to better understand its transport and storage across the lunar surface. We took into account several loss processes: ionization by solar photons, charge-exchange with solar protons, and cold trapping as computed by recent LRO/Lunar Orbiter Laser Altimeter (LOLA) mapping of Permanently Shaded Regions (PSRs). Recycling of photo-ions and solar radiation acceleration are also considered. We report that (i) contrary to previous assumptions, charge exchange is a loss process as efficient as photo-ionization, (ii) the PSR cold-trapping flux is comparable to the ionization flux (photo-ionization and charge-exchange), and (iii) solar radiation pressure has negligible effect on the argon density, as expected. We determine that the release of 2.6 × 1028 atoms on top of a pre-existing argon exosphere is required to explain the maximum amount of argon measured by LACE. The total number of atoms (1.0 × 1029) corresponds to ∼6700 kg of argon, 30% of which (∼1900 kg) may be stored in the cold traps after 120 days in the absence of space weathering processes. The required population is consistent with the amount of argon that can be released during a High Frequency Teleseismic (HFT) Event, i.e. a big, rare and localized moonquake, although we show that LACE could not distinguish between a localized and a global event. The density of argon measured at the time of LACE appears to have originated from no less than four such episodic events. Finally, we show that the extent of the PSRs that trap

  7. Depleted Argon from Underground Sources

    International Nuclear Information System (INIS)

    Argon is a strong scintillator and an ideal target for Dark Matter detection; however 39Ar contamination in atmospheric argon from cosmic ray interactions limits the size of liquid argon dark matter detectors due to pile-up. Argon from deep underground is depleted in 39Ar due to the cosmic ray shielding of the earth. In Cortez, Colorado, a CO2 well has been discovered to contain approximately 600 ppm of argon as a contamination in the CO2. We first concentrate the argon locally to 3% in an Ar, N2, and He mixture, from the CO2 through chromatographic gas separation, and then the N2 and He will be removed by continuous distillation to purify the argon. We have collected 26 kg of argon from the CO2 facility and a cryogenic distillation column is under construction at Fermilab to further purify the argon.

  8. Argon in action

    CERN Multimedia

    Corinne Pralavorio

    2015-01-01

    Over the past few days, the SPS has been accelerating argon ions, which have started to be sent to the NA61/SHINE experiment. This operating mode, using a new type of ion, required a number of modifications to the accelerator.   Picture 1: a “super-cycle” of the SPS, featuring a proton cycle for the LHC, followed by an argon ion cycle for the North Area. Today, the accelerators are once again juggling particles and even performing completely new tricks. The SPS is supplying beams of argon ions for the first time, at energies never before achieved for this type of beam. They are destined for the NA61/SHINE experiment (see box) located in the North Area, which began receiving the beams on 11 February. Argon ions have a relatively large mass, as they consist of 40 nucleons, so they can be used in a similar way to lead ions. The main difficulty in accelerating them lies in the SPS, where the variation in acceleration frequency is limited. “The SPS was designed for a...

  9. Thermophysical properties of argon

    Energy Technology Data Exchange (ETDEWEB)

    Jaques, A.

    1988-02-01

    The entire report consists of tables of thermodynamic properties (including sound velocity, thermal conductivity and diffusivity, Prandtl number, density) of argon at 86 to 400/degree/K, in the form of isobars over 0.9 to 100 bars. (DLC)

  10. The Argon Geochronology Experiment (AGE)

    Science.gov (United States)

    Swindle, T. D.; Bode, R.; Fennema, A.; Chutjian, A.; MacAskill, J. A.; Darrach, M. R.; Clegg, S. M.; Wiens, R. C.; Cremers, D.

    2006-01-01

    This viewgraph presentation reviews the Argon Geochronology Experiment (AGE). Potassium-Argon dating is shown along with cosmic ray dating exposure. The contents include a flow diagram of the Argon Geochronology Experiment, and schematic diagrams of the mass spectrometer vacuum system, sample manipulation mechanism, mineral heater oven, and the quadrupole ion trap mass spectrometer. The Laser-Induced Breakdown Spectroscopy (LIBS) Operation with elemental abundances is also described.

  11. Liquid argon neutrino detectors

    CERN Document Server

    Battistoni, G

    2001-01-01

    The liquid argon imaging technique, as proposed for the ICARUS detector, offers the possibility to perform complementary and simultaneous measurements of neutrinos, as those of CERN to Gran Sasso beam (CNGS) and those from cosmic ray events. For the currently allowed values of the Super-Kamiokande results, the combination of both CNGS and atmospheric data will provide a precise determination of the oscillation parameters. Since one can observe and unambiguously identify nu /sub e/, nu /sub mu / and nu /sub tau / components, this technology allows to explore the full (3*3) mixing matrix. The same class of detector can be proposed for high precision measurements at a neutrino factory. (3 refs).

  12. Argon Welding Inside A Workpiece

    Science.gov (United States)

    Morgan, Gene E.

    1988-01-01

    Canopies convert large hollow workpiece into inert-gas welding chamber. Large manifold serves welding chamber for attachment of liner parts in argon atmosphere. Every crevice, opening and passageway provided with argon-rich environment. Weld defects and oxidation dramatically reduced; also welding time reduced.

  13. Dechlorinating reaction of organic chlorides

    International Nuclear Information System (INIS)

    Dechlorination has been examined by the reaction between iron, aluminum powder or CaO and organic chlorides such as C2HCl3 and CH2Cl2. Progress of the reaction was analyzed with mass spectrometer. The reaction between iron and organic chloride was rapidly occurred at the temperature between 350 and 440degC in an atmosphere of argon. Above 380degC, more than 99.5% of C2HCl3 was decomposed within approximately 100 minutes. At 440degC, approximately 60% of C2HCl3 was decomposed by the reaction with aluminium powder within approximately 100 minutes. At 440degC, reaction between C2HCl3 and CaO powder were occurred rapidly in an atmosphere of argon to form CaCl2 and free carbon. Also in an atmosphere of air, nearly the same result was obtained. In this reaction, CaCl2, CO and CO2 were formed. CH2Cl2 was also decomposed by the reaction with iron at the temperature between 380 and 440degC. In the reaction, FeCl2, carbon and hydrogen were formed. CH3+ and CH4 were observed during the dechlorinating reaction of CH2Cl2. Variation in particle size of iron powder such as 100, 150 and 250 mesh did not affect the reaction rate. (author)

  14. Broadband Chirped-Pulse Fourier Transform Microwave Spectroscopy and Molecular Structure of the ARGON-{ {(Z)}}-1-CHLORO-2-FLUOROETHYLENE Complex

    Science.gov (United States)

    Marshall, Mark D.; Leung, Helen O.

    2012-06-01

    A chirped-pulse Fourier transform microwave spectrometer is used to obtain the 6--18 GHz rotational spectrum of the gas-phase complex formed between argon and (Z)-1-chloro-2-fluoroethylene. Both the 35Cl and 37Cl isotopologues are observed in natural abundance, and analysis of these spectra provides predictions for both singly-substituted 13C species with sufficient precision to allow their observation with minimal searching using the more sensitive narrow band Balle-Flygare cavity technique. The non-planar structure of the complex is similar to previously observed argon-fluoroethylene complexes with the argon atom closer to the fluorine than to the chlorine. In contrast to the argon-vinyl chloride and argon-cis-1,2-difluoroethylene complexes, tunneling of the argon atom between the two equivalent, non-planar geometries is not observed.

  15. Microwave Argon Plasma Torch

    Science.gov (United States)

    Felizardo, Edgar; Pencheva, Mariana; Benova, Evgenia; Dias, Fransisco; Tatarova, Elena

    2009-10-01

    A theoretical and experimental investigation of a microwave (2.45 GHz) Argon plasma torch driven by a surface wave is presented. The theoretical model couples in a self-consistent way the wave electrodynamics and the electron and heavy particle kinetics. The set of coupled equations includes: Maxwell's equations, the electron Boltzmann equation, including electron-electron collisions, and the particle balance equations for electrons, excited atoms (4s, 4p, 3d, 5s, 5p, 4d, 6s), and atomic (Ar^+) and molecular ions (Ar2^+). The input parameters of the model are: gas pressure (760 Torr), plasma radius (R = 0.75 cm), dielectric permittivity (ɛd = 4.0) and tube thickness (d = 0.15 cm) as well as the measured axial profile of the gas temperature (3500 K - 1500 K). The latter was determined from measurements of the rotational temperature of the OH molecular band in the range 306 - 315 nm. Phase and amplitude sensitive recording provides the data for the axial wavenumber and wave attenuation coefficient. The wavenumber decreases along the generated plasma torch. The electron density (Ne) axial profile as determined from measurements of Hβ Stark broadening is in agreement with the theoretical one.

  16. The Liquid Argon Purity Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Adamowski, M.; Carls, B.; Dvorak, E.; Hahn, A.; Jaskierny, W.; Johnson, C.; Jostlein, H.; Kendziora, C.; Lockwitz, S.; Pahlka, B.; Plunkett, R.; Pordes, S.; Rebel, B.; Schmitt, R.; Stancari, M.; Tope, T.; Voirin, E.; Yang, T.

    2014-07-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  17. Electrical conductivity of compressed argon

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, R. [Univ. Regensburg (Germany); Windl, W.; Collins, L.; Kress, J.; Kwon, I. [Los Alamos National Lab., NM (United States)

    1997-10-01

    The authors report calculations of the electrical conductivity of solid argon as a function of compression within the density functional local density approximation formulation for a norm-conserving pseudopotential using both electron-phonon coupling and molecular dynamics techniques.

  18. Testing a liquid Argon calorimeter

    CERN Multimedia

    1976-01-01

    Physicists from Karlsruhe test a liquid argon calorimeter in the neutral beam b16 at the PS. The calorimeter was meant to supply some neutral particles identification at the Split-Field Magnet Facility for R416.

  19. The Liquid Argon Purity Demonstrator

    CERN Document Server

    Adamowski, M; Dvorak, E; Hahn, A; Jaskierny, W; Johnson, C; Jostlein, H; Kendziora, C; Lockwitz, S; Pahlka, B; Plunkett, R; Pordes, S; Rebel, B; Schmitt, R; Stancari, M; Tope, T; Voirin, E; Yang, T

    2014-01-01

    The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

  20. Fano factor in pure argon

    International Nuclear Information System (INIS)

    The Fano factor for 5.3 MeV alpha particles in pure argon has been measured with a gridded ionization chamber and estimated to be 0.20 (+0.01-0.02). The obtained value is consistent with the theoretical value if the contribution of elastic nuclear collisions to the Fano factor is taken into the consideration. There is no appreciable difference between the values for pure argon and for a gas mixture of Ar (10%)CH4 obtained in the previous measurement. (orig.)

  1. Binocular indirect argon laser photocoagulator.

    OpenAIRE

    Mizuno, K

    1981-01-01

    The binocular indirect argon laser photocoagulator was newly designed to enable visualisation of the entire fundus during panretinal laser photocoagulation and to treat retinal tears immediately after buckling procedures of the sclera. The lamp housing of the binocular ophthalmoscope was remodelled and adjusted so that the laser beam and illuminating light are coaxial after leaving the ophthalmoscope. The blocking filter was permanently fixed in the eye-pieces to lighten the weight of the oph...

  2. Liquid Argon Barrel Cryostat Arrived

    CERN Multimedia

    Pailler, P

    Last week the first of three cryostats for the ATLAS liquid argon calorimeter arrived at CERN. It had travelled for 46 days over several thousand kilometers from Japan to CERN. During three years it has been fabricated by Kawasaki Heavy Industries Ltd. at Harima, close to Kobe, under contract from Brookhaven National Laboratory (BNL) of the U.S.. This cryostat consists of two concentric cylinders made of aluminium: the outer vacuum vessel with a diameter of 5.5 m and a length of 7 m, and the inner cold vessel which will contain the electromagnetic barrel calorimeter immersed in liquid argon. The total weight will be 270 tons including the detectors and the liquid argon. The cryostat is now located in building 180 where it will be equipped with 64 feed-throughs which serve for the passage of 122,880 electrical lines which will carry the signals of the calorimeter. After integration of the calorimeter, the solenoidal magnet of ATLAS will be integrated in the vacuum vessel. A final cold test of the cryostat inc...

  3. The scintillation of liquid argon

    CERN Document Server

    Heindl, T; Hofmann, M; Krücken, R; Oberauer, L; Potzel, W; Wieser, J; Ulrich, A

    2015-01-01

    A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd excimer continuum. Various additional emission features were found. The time structure of the light emission has been measured for a set of well defined wavelength positions. The results help to interpret literature data in the context of liquid rare gas detectors in which the wavelength information is lost due to the use of wavelength shifters.

  4. Chloride ingress prediction

    DEFF Research Database (Denmark)

    Frederiksen, Jens Mejer; Geiker, Mette Rica

    Prediction of chloride ingress into concrete is an important part of durability design of reinforced concrete structures exposed to chloride containing environment. This paper presents the state-of-the art: an analytical model which describes chloride profiles in concrete as function of depth and...... makes physical sense for the design engineer, i.e. the achieved chloride diffusion coefficients at 1 year and 100 years, D1 and D100 respectively, and the corresponding achieved chloride concentrations at the exposed concrete surface, C1 and C100. Data from field exposure supports the assumption of time...... dependent surface chloride concentrations and the diffusion coefficients. Model parameters for Portland cement concretes with and without silica fume and fly ash in marine atmospheric and submerged South Scandinavian environment are suggested in a companion paper based on 10 years field exposure data....

  5. Chloride ingress prediction

    DEFF Research Database (Denmark)

    Frederiksen, Jens Mejer; Geiker, Mette Rica

    Prediction of chloride ingress into concrete is an important part of durability design of reinforced concrete structures exposed to chloride containing environment. This paper presents experimentally based design parameters for Portland cement concretes with and without silica fume and fly ash in...... marine atmospheric and submersed South Scandinavian environment. The design parameters are based on sequential measurements of 86 chloride profiles taken over ten years from 13 different types of concrete. The design parameters provide the input for an analytical model for chloride profiles as function...

  6. Transition probabilities for argon I

    International Nuclear Information System (INIS)

    Transition probabilities for ArI lines have been calculated on the basis of the (j,k)-coupling scheme for more than 16000 spectral lines belonging to the transition arrays 4s-np (n=4 to n=9), 5s-np (n=5 to n=9), 6s-np (n=6 to n=9), 7s-np (n=8 to n=9), 4p-ns (n=5 to n=10), 5p-ns (n=6 to n=9), 6p-ns (n=7 to n=8), 4p-nd (n=3 to n=9), 5p-nd (n=4 to n=9), 3d-np (n=5 to n=9), 4d-np (n=6 to n=9), 5d-np (n=7 to n=9), 3d-nf (n=4 to n=9), 4d-nf (n=4 to n=9), 5d-nf (n=5 to n=9), 4f-nd (n=5 to n=9) 5f-nd (n=6 to n=9), 4f-ng (n=5 to n=9), 5f-ng (n=6 to n=9). Inso far as values by other authors exist, comparison is made with these values. It turns out that the results obtained in (j,k)-coupling are close to those obtained in intermediate coupling except for intercombination lines. For high principal and/or orbital quantum numbers the transition probabilities for a multiplet approach those of the corresponding transitions in atomic hydrogen. The calculated values are applied to construct a simplified argon-atom model, which reflects the real transition properties and which allows simplified but realistic non-equilibrium calculations for argon plasmas which deviate from local thermodynamic equilibrium (LTE)

  7. Chloride ingress prediction

    DEFF Research Database (Denmark)

    Frederiksen, Jens Mejer; Geiker, Mette Rica

    2008-01-01

    Prediction of chloride ingress into concrete is an important part of durability design of reinforced concrete structures exposed to chloride containing environment. This paper presents experimentally based design parameters for Portland cement concretes with and without silica fume and fly ash in...

  8. The isolation of beryllium and mercury from lithium chloride solution by means of gas extraction

    International Nuclear Information System (INIS)

    The possibility and optimal conditions of beryllium and mercury extraction using acetylacetone (HAA) from lithium chloride solution by argon blowing through the solution are determined. Dependences of extraction degrees and distribution coefficients on different parameters of liquid phase: initial pH value, lithium chloride concentration and initial content of HAA, are presented. The degree of beryllium extraction reaches the maximum at liquid phase pH of 4.4-5.25 and concentration of lithium chloride of 8.5 mol/l. Distribution coefficient changes in inverse proportion to the extraction degree

  9. Argon-39 Background in DUNE Photon Detectors

    Science.gov (United States)

    Sinev, Gleb; DUNE Collaboration

    2016-03-01

    The Deep Underground Neutrino Experiment (DUNE) is a 40-kt liquid argon detector that will be constructed 5000 ft underground in the Sanford Underground Research Facility in order to study neutrino and proton decay physics. Instrumenting liquid argon with photon detectors to record scintillation in addition to the ionization signal can significantly improve time and energy resolution of the experiment. Argon produces light with wavelength of 128 nm. The reference design for the photon detectors includes acrylic bars covered in wavelength shifter, where the scintillation light can be captured and reemitted with longer wavelengths, then detected using silicon photomultipliers. Radiological backgrounds may noticeably deteriorate the photon detection system performance, especially for low-energy interactions. A particularly important background comes from argon-39 decays, because argon-39 is present in natural argon that will be used in DUNE and the background rate increases with the size of the experiment. The effect of the argon-39 background has been studied and is presented in this talk.

  10. Emissive spectra of shock-heated argon

    International Nuclear Information System (INIS)

    To study the radiant properties of argon under weak shock compression, an aluminum target filled with gaseous argon at ambient states was impacted by a tungsten alloy projectile which was launched from a two-stage light gun to 2.00 km/s. The radiant signals of single shock-compressed argon were recorded by a six-channel pyrometer and oscilloscopes, which varied with time linearly for the five channels from 405 nm to 700 nm and exponentially for the channel 800 nm, and the corresponding velocity of shock wave was determined to be 4.10 ± 0.09 km/s. By the present experiment, it has been shown that the absorbability of the shock-heated argon is low for visual light and the optical depths of argon gas turn from thin to thick as wavelengths gradually increase. The time-resolved spectra in the rising-front of the radiant signal in the re-shocked argon were recorded by means of an OMA, and strong emissive spectrum bands near 450 nm light-wave length but no linear spectrum were found. The emissive spectrum properties of shock-compression argon were qualitatively explained by the state parameters and ionization degree

  11. Argon plasma irradiation of polypropylene

    International Nuclear Information System (INIS)

    Polypropylene samples were exposed to argon plasma discharge and the changes of the PP surface properties were studied by different methods. Surface wettability was derived from contact angle measured by standard goniometry and chemical structure of the plasma modified PP was studied using X-ray photoelectron spectroscopy (XPS) and by Rutherford backscattering spectroscopy (RBS), surface morphology and roughness of samples using AFM. Zeta potential of pristine and modified PP was determined with the SurPASS. The presence of incorporated oxygen in the PP surface layer, about 60 nm thick, was observed in RBS spectra. Oxygen concentration is a decreasing function of the depth. With progressing aging time the oxygen concentration on the PP surface decreases. Plasma treatment results in a rapid decrease of the contact angle, which increases again with increasing aging time. In XPS measurement the oxygen containing structures, created by the plasma treatment, were found on the very surface of the modified PP and the zeta potential being changed too. The significant difference in zeta potential between pristine and plasma treated PP clearly indicates that the plasma treatment leads to a more hydrophilic PP surface.

  12. Chloride ingress prediction

    DEFF Research Database (Denmark)

    Frederiksen, Jens Mejer; Geiker, Mette Rica

    2008-01-01

    makes physical sense for the design engineer, i.e. the achieved chloride diffusion coefficients at 1 year and 100 years, D1 and D100 respectively, and the corresponding achieved chloride concentrations at the exposed concrete surface, C1 and C100. Data from field exposure supports the assumption of time...... dependent surface chloride concentrations and the diffusion coefficients. Model parameters for Portland cement concretes with and without silica fume and fly ash in marine atmospheric and submerged South Scandinavian environment are suggested in a companion paper based on 10 years field exposure data....

  13. Status and perspecitves of liquid argon calorimeters

    International Nuclear Information System (INIS)

    The status of liquid argon calorimeters is reviewed, and experience obtained with these devices is described. Future perspectives of the liquid ionization chamber technique in calorimetry are also discussed. (orig.)

  14. Clinical periodontics with the argon laser

    Science.gov (United States)

    Finkbeiner, R. L.

    1995-04-01

    The argon laser has proven to be a valuable tool for the thermodynamic debridement of the periodontal lesion, incisions and tissue fusion. Illustrations of clinical applications and discussion of laser parameters will be provided.

  15. Liquid argon neutrals detector (LAND) for PEP

    International Nuclear Information System (INIS)

    The physical effects limiting the gamma energy resolution of a liquid argon calorimeter without passive converter plates is discussed. An example of such a detector based on the General User's Magnet designed at this Summer Study is given

  16. Opacity of Shock-Generated Argon Plasmas

    Institute of Scientific and Technical Information of China (English)

    王藩侯; 陈敬平; 周显明; 李西军; 经福谦; 孟续军; 孙永盛

    2001-01-01

    Argon plasmas with uniform density and temperature are generated by a planar shock wave through argon gas. The opacities of argon plasma, covering the thermodynamic states at temperatures of 1.4-2.2eV and in densities of 0.0083- 0.015 g/cm3, are investigated by measuring the emitted radiance versus time at several visible wavelengths. Comparison of the measured opacities with those calculated demonstrates that the average atom model can be used well to describe the essential transport behaviour of photons in argon plasma under the abovementioned thermodynamic condition. A simplified and self-consistent method to deduce the reflectivity R(λ) at the baseplate surface is applied. It demonstrates that the values of R(λ) are all around 0.4 in the experiments, which are basically in agreement with those given by Erskine previously (1994 J. Quant. Spectrosc. Radiat.Transfer 51 97).

  17. 21 CFR 868.1075 - Argon gas analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Argon gas analyzer. 868.1075 Section 868.1075 Food... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1075 Argon gas analyzer. (a) Identification. An argon gas analyzer is a device intended to measure the concentration of argon in a gas mixture to aid...

  18. Negative corona current pulses in argon and in mixture argon with SF6

    International Nuclear Information System (INIS)

    Waveforms of the first negative current pulses in a short negative point-to plane gap in pure argon and argon with SF6 admixture have been investigated with a nanosecond time resolution at a gas pressure 50 kPa as a function of applied gap voltage and content of SF6 in the mixture. We have made an attempt to explain the differences in the discharge development in pure argon and in argon with admixture of SF6 based on the observed changes of the pulse shape. The experimental results obtained will be discussed in context with existing computer simulation models (Authors)

  19. Measurements on scintillation light from liquid argon

    International Nuclear Information System (INIS)

    It is shown that an argon calorimeter can operate as a scintillation detector, provided that xenon is added. With the addition of 170 ppm xenon a light yield of 70% has been obtained. In addition the light yield is determined under influence of an electric field, from differently ionising particles and by the use of aluminium mirrors acting as light guides. Finally first measurements with a photomultiplier working at liquid argon temperatures are reported. (orig.)

  20. Potassium-argon/argon-40-argon-39 geochronology of Cenozoic alkali basalts from the South China Sea

    Institute of Scientific and Technical Information of China (English)

    YAN Quanshu; SHI Xuefa; YANG Yaomin; WANG Kunshan

    2008-01-01

    Based on the isotopic chronologic results of Cenozoic alkali basalts from the South China Sea,the characteristics of volcanic activi-ty of the South China Sea after spreading were studied.The potassium - argon ages of eight alkali basalt samples from the South China Sea,and the argon - argon ages of two samples among them are reported.Apparent ages of the whole rock are 3.80 to 7.91 Ma with an average value of 5.43 Ma (potassium- argon,whole rock),and there is little difference among samples at the same location,e.g.,4.76~5.78 Ma for location S04-12.The argon - argon ages for the two samples are 6.06 and 4.71 Ma,which lie within the age scope of potassium - argon method.The dating results indicate that rock-forming age is from late Miocene to Pli-ocene,which is consistent with erupting event for alkali basalts from adjacent regions of the South China Sea.Volcanic activities occur after the cessation of spreading of the South China Sea,which are controlled by lithospheric fault and the spreading center formed during the spreading period of the South China Sea.These dating results,combined with geochemical characteristics of these basalts,the published chronological data for the South China Sea and its adjacent regions,and the updated geophysical data near Hainan Island,suggest that after the cessation of spreading of the South China Sea,there occur widely distributing magmatic activities which primarily is alkali basalt,and the volcanic activity continues to Quaternary.The activity may be relative to Hainan mantle plume originated from core/mantle boundary.

  1. Shock tube study of ionization rates of NaCl-contaminated argon

    Science.gov (United States)

    Schneider, K.-P.; Park, C.

    1975-01-01

    Electron density, electron temperature, and concentration of excited sodium atoms are measured in the weakly ionized regime behind a shock wave in impure argon in a shock tube using microwave techniques and spectrally resolved radiometry. Evidence is presented to show that an apparent increase in the rate of ionization is due to electron detachment of negative chlorine ions produced from sodium chloride vapor contained as an impurity. To be consistent with this chemical model, rate coefficients are found in the temperature range between 5500 and 8600 K for the dissociation of NaCl into an ion pair, dissociation of NaCl into a neutral pair, and electron detachment of a negative chlorine ion. Electron temperature is lower than heavy-particle temperature by roughly 1000 K. The electron-argon impact-ionization rate coefficient is a weak function of electron temperature in contradiction to expectation.

  2. Argon Collection And Purification For Proliferation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Achey, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hunter, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-09

    In order to determine whether a seismic event was a declared/undeclared underground nuclear weapon test, environmental samples must be taken and analyzed for signatures that are unique to a nuclear explosion. These signatures are either particles or gases. Particle samples are routinely taken and analyzed under the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) verification regime as well as by individual countries. Gas samples are analyzed for signature gases, especially radioactive xenon. Underground nuclear tests also produce radioactive argon, but that signature is not well monitored. A radioactive argon signature, along with other signatures, can more conclusively determine whether an event was a nuclear test. This project has developed capabilities for collecting and purifying argon samples for ultra-low-background proportional counting. SRNL has developed a continuous gas enrichment system that produces an output stream containing 97% argon from whole air using adsorbent separation technology (the flow diagram for the system is shown in the figure). The vacuum swing adsorption (VSA) enrichment system is easily scalable to produce ten liters or more of 97% argon within twelve hours. A gas chromatographic separation using a column of modified hydrogen mordenite molecular sieve has been developed that can further purify the sample to better than 99% purity after separation from the helium carrier gas. The combination of these concentration and purification systems has the capability of being used for a field-deployable system for collecting argon samples suitable for ultra-low-background proportional counting for detecting nuclear detonations under the On-Site Inspection program of the CTBTO verification regime. The technology also has applications for the bulk argon separation from air for industrial purposes such as the semi-conductor industry.

  3. Kinetic and experimental study of argon and argon--nitrogen mixtures excited by fission fragments

    International Nuclear Information System (INIS)

    Optical emission from argon and argon-nitrogen mixtures excited by fission fragments are studied in an effort to better understand the fission fragment energy deposition into the gas. A model of the energy flow in the gas is developed and compared with the experimental results

  4. Argon activation analysis, application to dating by the potassium-argon method

    International Nuclear Information System (INIS)

    Activation analysis using radiogenic argon-40 has been applied to rock-dating by the K-Ar method. The argon is extracted from the sample, purified, activated to saturation in a flux of 2 X 1013 neutrons/cm2 sec-1 and measured by gamma spectroscopy. The sensitivity obtained is such that it is possible to measure amounts of argon corresponding to age of a few thousand years only. However since it has not been possible to measure the amount of pollution of radiogenic argon by atmospheric argon with any accuracy, the measurable age limit is in fact of the order of MY. The method has been applied to basalts from the Mont-Dore region. The results obtained are in fairly good agreement with geological, stratigraphic and paleomagnetic data. (author)

  5. Mass transport in aqueous zinc chloride-potassium chloride electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Leaist, D.G.

    1986-09-01

    Conductimetric and diaphragm cell techniques have been used to measure ternary diffusion coefficients for aqueous zinc chloride-potassium chloride solutions at 25/sup 0/C. At low concentrations where Zn/sup 2 +/ is the major zinc-transporting species, the diffusion-induced electric field along zinc chloride concentration gradients drives large co-current flows of potassium chloride. In concentrated solutions where a large proportion of zinc diffusses as anionic ZnCl/sub 3//sup -/ and ZnCl/sub 4//sup 2 -/ complexes, flow of zinc chloride generates counterflow of potassium chloride. If a sharp zinc chloride is formed in an otherwise uniform solution of potassium chloride, coupled diffusion can concentrate potassium ions within the diffusion boundary. Equations are developed to predict multicomponent transport coefficients for zinc chloride in supporting electrolytes.

  6. Attenuation of vacuum ultraviolet light in liquid argon

    CERN Document Server

    Neumeier, A; Oberauer, L; Potzel, W; Schönert, S; Dandl, T; Heindl, T; Ulrich, A; Wieser, J

    2015-01-01

    The transmission of liquid argon has been measured, wavelength resolved, for a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation length is presented for pure argon. It is shown that no universal wavelength independent attenuation length can be assigned to liquid argon for its own fluorescence light due to the interplay between the wavelength dependent emission and absorption. A decreasing transmission is observed below 130 nm in both chemically cleaned and distilled liquid argon and assigned to absorption by the analogue of the first argon excimer continuum. For not perfectly cleaned argon a strong influence of impurities on the transmission is observed. Two strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm width, respectively, are assigned to traces of xenon in argon. A broad absorption region below 180 nm is found for unpurified argon and tentatively attributed to the presence of water in the argon sample.

  7. Rietveld refinement of CdSe phases annealed under argon atmosphere

    Science.gov (United States)

    Mesquita, A. F.; Bernardes-Silva, A. C.; Porto, A. O.; de Lima, G. M.; de Miranda-Pinto, C. O. B.; Delgado, J. M.; de Chalbaud, L. M.; Lameiras, F. S.; Paniago, R.

    2005-10-01

    Hexagonal and cubic cadmium selenide were prepared from a chemical route by using cadmium chloride and potassium selenium hydride obtained from reaction of selenium powder and potassium boron hydride. The product obtained was thermally treated under argon flux at 300, 500 and 600 °C for 2 h and characterized by X-ray photoelectron spectroscopy and X-ray diffraction. The X-ray diffraction data were refined by Rietveld method and the structural parameters were determined for the phases of each annealed samples. At 300 °C five phases were identified: Cubic and hexagonal cadmium selenides and the contaminants: Potassium chloride, boron oxide and cadmium boron oxide. At 500 and 600 °C only the hexagonal cadmium selenide phase was identified besides the other above mentioned contaminant.

  8. Chloride removal from vitrification offgas

    International Nuclear Information System (INIS)

    This study identified and investigated techniques of selectively purging chlorides from the low-level waste (LLW) vitrification process with the purge stream acceptable for burial on the Hanford Site. Chlorides will be present in high concentration in several individual feeds to the LLW Vitrification Plant. The chlorides are highly volatile in combustion type melters and are readily absorbed by wet scrubbing of the melter offgas. The Tank Waste Remediation System (TWRS) process flow sheets show that the resulting chloride rich scrub solution is recycled back to the melter. The chlorides must be purged from the recycle loop to prevent the buildup of excessively high chloride concentrations

  9. Scintillation efficiency of liquid argon in low energy neutron-argon scattering

    International Nuclear Information System (INIS)

    Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the response of the detector at low energy. We report the results obtained with a small liquid argon cell using a monoenergetic neutron beam produced by a deuterium-deuterium fusion source. The light yield relative to electrons was measured for six argon recoil energies between 11 and 120 keV at zero electric drift field

  10. Contraction ionization waves in the argon contracted discharge

    International Nuclear Information System (INIS)

    An investigation of ionization waves in the argon contracted discharge and a definition of their arising propagation mechanism accounting for the specificity of elementary pocesses characteristic of argon are presented. (author)

  11. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...

  12. Antiapoptotic activity of argon and xenon.

    Science.gov (United States)

    Spaggiari, Sabrina; Kepp, Oliver; Rello-Varona, Santiago; Chaba, Kariman; Adjemian, Sandy; Pype, Jan; Galluzzi, Lorenzo; Lemaire, Marc; Kroemer, Guido

    2013-08-15

    Although chemically non-reactive, inert noble gases may influence multiple physiological and pathological processes via hitherto uncharacterized physical effects. Here we report a cell-based detection system for assessing the effects of pre-defined gas mixtures on the induction of apoptotic cell death. In this setting, the conventional atmosphere for cell culture was substituted with gas combinations, including the same amount of oxygen (20%) and carbon dioxide (5%) but 75% helium, neon, argon, krypton, or xenon instead of nitrogen. The replacement of nitrogen with noble gases per se had no effects on the viability of cultured human osteosarcoma cells in vitro. Conversely, argon and xenon (but not helium, neon, and krypton) significantly limited cell loss induced by the broad-spectrum tyrosine kinase inhibitor staurosporine, the DNA-damaging agent mitoxantrone and several mitochondrial toxins. Such cytoprotective effects were coupled to the maintenance of mitochondrial integrity, as demonstrated by means of a mitochondrial transmembrane potential-sensitive dye and by assessing the release of cytochrome c into the cytosol. In line with this notion, argon and xenon inhibited the apoptotic activation of caspase-3, as determined by immunofluorescence microscopy coupled to automated image analysis. The antiapoptotic activity of argon and xenon may explain their clinically relevant cytoprotective effects. PMID:23907115

  13. Argon-ion contamination of the plasmasphere

    International Nuclear Information System (INIS)

    This paper applies present observational and analytic knowledge on effects of plasma beam interaction wth the magnetosphere to the plasmasphere contamination problem of the argon ion engine exhaust expected to be deposited in the magnetosphere during the construction phase of the Satellite Power System. Effects of plasmasphere, ionosphere, and radiation belt modifications are discussed

  14. Near-infrared scintillation of liquid argon

    Science.gov (United States)

    Alexander, T.; Escobar, C. O.; Lippincott, W. H.; Rubinov, P.

    2016-03-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 μm motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  15. Silicon compounds of neon and argon

    Czech Academy of Sciences Publication Activity Database

    Roithová, J.; Schröder, Detlef

    -, č. 46 (2009), s. 8788-8790. ISSN 1433-7851 R&D Projects: GA ČR GA203/09/1223 Grant ostatní: ERC(XE) Adg HORIZOMS Institutional research plan: CEZ:AV0Z40550506 Keywords : argon * bond formation * dications * neon Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 11.829, year: 2009

  16. Argon Laser Treatment of Strawberry Hemangioma in Infancy

    OpenAIRE

    Achauer, Bruce M.; Vander Kam, Victoria M.

    1985-01-01

    Argon laser therapy is effective for removing port-wine stains and for reducing cutaneous vascular and pigmented lesions. Strawberry hemangiomas, being much thicker lesions than port-wine stains, were considered not appropriate for argon laser treatment. Using argon laser therapy in 13 cases of strawberry hemangioma, we achieved poor to dramatic results.

  17. [Degradation of succinylcholine chloride].

    Science.gov (United States)

    Németh, G; Török, I; Paál, T

    1993-05-01

    Quantitative thin-layer chormatographic method has been developed for the investigation of the degradation of injection formulations containing succinylcholinium chloride. The method is based on the denistometric determination of the main degradation product, choline at 430 nm after visualization with iodine vapour. The stability of the injection was investigated under various storage conditions and it has been stated that considerable decomposition takes place during as short a period as one week. PMID:8362654

  18. Argon laser irradiation of the otolithic organ

    Energy Technology Data Exchange (ETDEWEB)

    Okuno, T.; Nomura, Y.; Young, Y.H.; Hara, M. (Univ. of Tokyo (Japan))

    1990-12-01

    An argon laser was used to irradiate the otolithic organs of guinea pigs and cynomolgus monkeys. After stapedectomy, the argon laser (1.5 W x 0.5 sec/shot) irradiated the utricle or saccule without touching the sensory organs. The stapes was replaced over the oval window after irradiation. The animals used for acute observation were killed immediately for morphologic studies; those used for long-term observation were kept alive for 2, 4, or 10 weeks. Acute observation revealed that sensory and supporting cells were elevated from the basement membrane only in the irradiated area. No rupture of the membranous labyrinth was observed. Long-term observation revealed that the otolith of the macula utriculi had disappeared in 2-week specimens. The entire macula utricili had disappeared in 10-week specimens. No morphologic changes were observed in cochlea, semicircular canals, or membranous labyrinth. The saccule showed similar changes.

  19. Explanation of the memory effect in argon

    Directory of Open Access Journals (Sweden)

    Marković Vidosav

    2005-01-01

    Full Text Available Memory effect - the long time variation of the electrical breakdown time delay on the relaxation time td (τ was observed in argon 24 hours after relaxation times and explained by the long-lived metastable states remaining from the preceding glow. However, the quenching processes reducing the effective lifetime of metastable states several orders of magnitude below that relevant for the time scale of observation were neglected. By applying approximate gas phase models it was found that the early afterglow kinetics up to hundreds of milliseconds is dominated by the decay of molecular argon ions Ar2+ and the approximate value of their ambipolar diffusion coefficient is determined. After that, nitrogen atoms present as impurities and recombined on the cathode surface and/or field emission determine the breakdown time delay down to the cosmic rays and natural radioactivity level.

  20. Flow Parameters of Argon plasma Discharge

    International Nuclear Information System (INIS)

    Owing to the viscosity, the plasma will be adhering to the inner surface of the outer electrode and outer surface of the inner one. As result that the discharge will be eroding the walls of coaxial system. The thickness of the boundary layer near the walls has been estimated at different positions from the breech of coaxial plasma gun. It is found that the thickness of layer 0.008 cm at the end of inner electrode (17 cm). A coaxial plasma gun device is operated in argon gas at ambient pressure 0.6 Torr and discharge voltage about 10 KV. The electron temperature of argon discharge has been determined by using spectroscopic technique. It is found that kTe=3.4 eV. By knowing the thickness of the boundary layer, the density can be determined. The Reynolds number R=105 and Mach number M=5 i.e. the flow is compressible and hypersonic

  1. ATLAS liquid argon calorimeter back end electronics

    CERN Document Server

    Bán, J; Bellachia, F; Blondel, A; Böttcher, S; Clark, A; Colas, Jacques; Díaz-Gómez, M; Dinkespiler, B; Efthymiopoulos, I; Escalier, M; Fayard, Lo; Gara, A; He, Y; Henry-Coüannier, F; Hubaut, F; Ionescu, G; Karev, A; Kurchaninov, L; Lafaye, R; Laforge, B; La Marra, D; Laplace, S; Le Dortz, O; Léger, A; Liu, T; Martin, D; Matricon, P; Moneta, L; Monnier, E; Oberlack, H; Parsons, J A; Pernecker, S; Perrot, G; Poggioli, L; Prast, J; Przysiezniak, H; Repetti, B; Rosselet, L; Riu, I; Schwemling, P; Simion, S; Sippach, W; Strässner, A; Stroynowski, R; Tisserant, S; Unal, G; Wilkens, H; Wingerter-Seez, I; Xiang, A; Yang, J; Ye, J

    2007-01-01

    The Liquid Argon calorimeters play a central role in the ATLAS (A Toroidal LHC Apparatus) experiment. The environment at the Large Hadron Collider (LHC) imposes strong constraints on the detectors readout systems. In order to achieve very high precision measurements, the detector signals are processed at various stages before reaching the Data Acquisition system (DAQ). Signals from the calorimeter cells are received by on-detector Front End Boards (FEB), which sample the incoming pulse every 25ns and digitize it at a trigger rate of up to 75~kHz. Off-detector Read Out Driver (ROD) boards further process the data and send reconstructed quantities to the DAQ while also monitoring the data quality. In this paper, the ATLAS Liquid Argon electronics chain is described first, followed by a detailed description of the off-detector readout system. Finally, the tests performed on the system are summarized.

  2. Current and future liquid argon neutrino experiments

    International Nuclear Information System (INIS)

    The liquid argon time projection chamber (LArTPC) detector technology provides an opportunity for precision neutrino oscillation measurements, neutrino cross section measurements, and searches for rare processes, such as SuperNova neutrino detection. These proceedings review current and future LArTPC neutrino experiments. Particular focus is paid to the ICARUS, MicroBooNE, LAr1, 2-LArTPC at CERN-SPS, LBNE, and 100 kton at Okinoshima experiments

  3. Liquid argon imaging a novel detection technology

    CERN Document Server

    Rubbia, Carlo

    2002-01-01

    Ionisation electrons may drift over large distances (meters) in a volume of highly purified liquid argon (O2 equivalent less than 0.1 ppb!) under the action of an electric field. With an appropriate readout system (i.e. a set of fine pitch wire grids) we have realised a massive, continuously sensitive 'bubble chamber' with multiple readouts of the same, small charge (a minimum ionising track segment, 2 mm long, yields • 10000 electrons). We have developed this technology since 1987, initially with small laboratory devices and later with progressively larger and more sophisticated detectors, the latest being the T600 module (740 ton of liquid Argon), which has been operated in Pavia, as a step toward the ICARUS programme in the Gran Sasso Laboratory (LNGS). With cloning of T600 we aim at a 3000 ton detector by 2005. Argon is a medium with density 1.4 g/cm3, similar in characteristics to the heavy freon used in the famous Gargamelle. With wire pitches of 2-3 mm, it provides an extremely high spatial re...

  4. Distribution and Abundance of Mars' Atmospheric Argon

    Science.gov (United States)

    Sprague, A. L.; Boynton, W. V.; Kerry, K. E.; Nelli, Steven; Murphy, Jim; Reedy, R. C.; Metzger, A. E.; Hunten, D. M.; Janes, K. D.; Crombie, M. K.

    2005-01-01

    One and one half Mars years (MY 26 and 27) of atmospheric Argon measurements are described and studied in the context of understanding how Argon, a minor constituent of Mars atmosphere that does not condense at Mars temperatures, can be used to study martian circulation and dynamics. Argon data are from the 2001 Mars Odyssey Gamma Subsystem (GS) of the suite of three instruments comprising the Gamma Ray Spectrometer (GRS). A comprehensive data analysis including gamma-ray production and attenuation by the atmosphere is included. Of particular interest is the enhanced abundance of Ar over the observed Ar abundance at lower latitudes at south (up to a factor of 10) and north (up to a factor of 4) polar regions during winter. Calibration of the measurements to actual Ar abundance is possible because GS measurements cover the same latitude and season as measurements made by the gas chromatograph mass spectrometer (GCMS) on Viking Landers 1 and 2 (VL1 and VL2). [2].

  5. Development of a low-cost inductively coupled argon plasma

    International Nuclear Information System (INIS)

    The aim of this investigation is to drastically reduce running costs of an inductively coupled plasma. This is done by reducing the argon consumption from 20 l/min to about 1 l/min. First, a sample introduction system operating on 0.1 l/min of carrier argon is described. This system ensures a high ratio of plasma argon and carrier argon even at the low total argon consumptions intended. Next, the developed low consumption plasma is presented. In the proposed design, air is blown perpendicularly against the outside of the torch. A different coil has been developed to make air-cooling efficient. Preliminary data on coupling efficiency for the air-cooled plasma are presented. A similarly low argon consumption has been achieved with water as an external coolant medium. It is concluded that a cheaper alternative to the current ICP has become available. (Auth.)

  6. Direct WIMP Detection Using Scintillation Time Discrimination in Liquid Argon

    OpenAIRE

    Boulay, M. G.; Hime, A.

    2004-01-01

    Discrimination between electron and nuclear recoil events in a liquid argon scintillation detector has been demonstrated with simulations by using the differences in the scintillation photon time distribution between these classes of events. A discrimination power greater than 10^{8} is predicted for a liquid argon experiment with a 10 keV threshold, which would mitigate electron and gamma-ray backgrounds, including beta decays of 39-Ar and 42-Ar in atmospheric argon. A dark matter search usi...

  7. Effects of Nitrogen contamination in liquid Argon

    Science.gov (United States)

    Acciarri, R.; Antonello, M.; Baibussinov, B.; Baldo-Ceolin, M.; Benetti, P.; Calaprice, F.; Calligarich, E.; Cambiaghi, M.; Canci, N.; Carbonara, F.; Cavanna, F.; Centro, S.; Cocco, A. G.; Di Pompeo, F.; Fiorillo, G.; Galbiati, C.; Gallo, V.; Grandi, L.; Meng, G.; Modena, I.; Montanari, C.; Palamara, O.; Pandola, L.; Piano Mortari, G. B.; Pietropaolo, F.; Raselli, G. L.; Roncadelli, M.; Rossella, M.; Rubbia, C.; Segreto, E.; Szelc, A. M.; Ventura, S.; Vignoli, C.

    2010-06-01

    A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. The purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from ~ 10-1 ppm up to ~ 103 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (γ-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. Direct PMT signal acquisition exploiting high time resolution by fast waveform recording allowed high precision extraction of the main characteristics of the scintillation light emission in contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable starting from Script O(1 ppm) of Nitrogen concentrations. The rate constant of the quenching process induced by Nitrogen in liquid Ar has been found to be kQ(N2) = 0.11 ± 0.01 μs-1ppm-1, consistent with a previous measurement of this quantity but with significant improvement in precision. On the other hand, no evidence for absorption by N2 impurities has been found up to the higher concentrations here explored.

  8. HARP: high pressure argon readout for calorimeters

    International Nuclear Information System (INIS)

    Steel tubes of approximately 8 mm O.D., filled with Argon gas to approx.200 bar, are considered as the active element for a charge collecting sampling calorimeter readout system. The tubes are permanently sealed and operated in the ion chamber mode, with the charge collection on a one-millimeter concentric anode. We present the motivation for such a device, including Monte Carlo predictions of performance. The method of construction and signal collection are discussed, with initial results on leakage and ageing of the filling gas. A prototype electromagnetic calorimeter is described

  9. Argon isotope fractionation induced by stepwise heating

    Science.gov (United States)

    Trieloff, Mario; Falter, Martina; Buikin, Alexei I.; Korochantseva, Ekaterina V.; Jessberger, Elmar K.; Altherr, Rainer

    2005-03-01

    Noble gas isotopes are widely used to elucidate the history of the rocks in which they have been trapped, either from distinct reservoirs or by accumulation following radioactive decay. To extract noble gases from their host rocks, stepwise heating is the most commonly used technique to deconvolve isotopically different components, e.g., atmospheric, in situ radiogenic, or excess radiogenic from mantle or crustal reservoirs. The accurate determination of the isotopic composition of these different components is of crucial importance, e.g., for ages obtained by 40Ar- 39Ar stepheating plateaus. However, diffusion theory-based model calculations predict that the stepwise thermal extraction process from mineral phases induces isotope fractionation and, hence, adulterates the original composition. Such effects are largely unconsidered, as they are small and a compelling experimental observation is lacking. We report the first unequivocal evidence for significant mass fractionation of argon isotopes during thermal extraction, observed on shungite, a carbon-rich Precambrian sedimentary rock. The degree of fractionation, as monitored by 38Ar/ 36Ar and 40Ar/ 36Ar ratios, very well agrees with theoretical predictions assuming an inverse square root dependence of diffusion coefficient and atomic mass, resulting in easier extraction of lighter isotopes. Hence, subatmospheric 40Ar/ 36Ar ratios obtained for argon extracted at low temperatures may not represent paleoatmospheric argon. Shungite argon resembles modern atmospheric composition, but constraints on the timing of trapping appear difficult to obtain, as shungites are multicomponent systems. In 40Ar- 39Ar stepwise heating, the isotope fractionation effect could cause systematic underestimations of plateau ages, between 0.15 and 0.4% depending on age, or considerably higher if samples contain appreciable atmospheric Ar. The magnitude of this effect is similar to the presently achieved uncertainties of this increasingly

  10. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  11. Near-infrared scintillation of liquid argon

    CERN Document Server

    Alexander, T; Lippincott, W H; Rubinov, P

    2016-01-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  12. Attosecond Time-Resolved Autoionization of Argon

    International Nuclear Information System (INIS)

    Autoionization of argon atoms was studied experimentally by transient absorption spectroscopy with isolated attosecond pulses. The peak position, intensity, linewidth, and shape of the 3s3p6np 1P Fano resonance series (26.6-29.2 eV) were modified by intense few-cycle near infrared laser pulses, while the delay between the attosecond pulse and the laser pulse was changed by a few femtoseconds. Numerical simulations revealed that the experimentally observed splitting of the 3s3p64p 1P line is caused by the coupling between two short-lived highly excited states in the strong laser field.

  13. Valyl benzyl ester chloride

    Directory of Open Access Journals (Sweden)

    Grzegorz Dutkiewicz

    2010-02-01

    Full Text Available In the title compound (systematic name: 1-benzyloxy-3-methyl-1-oxobutan-2-aminium chloride, C12H18NO2+·Cl−, the ester group is approximately planar, with a maximum deviation of 0.040 (2 Å from the least-squares plane, and makes a dihedral angle of 28.92 (16° with the phenyl ring. The crystal structure is organized by N—H...Cl hydrogen bonds which join the two components into a chain along the b axis. Pairs of chains arranged antiparallel are interconnected by further N—H...Cl hydrogen bonds, forming eight-membered rings. Similar packing modes have been observed in a number of amino acid ester halides with a short unit-cell parameter of ca 5.5 Å along the direction in which the chains run.

  14. Argon Purification Studies and a Novel Liquid Argon Re-circulation System

    CERN Document Server

    Mavrokoridis, K; Coleman, J; Lightfoot, P K; McCauley, N; McCormick, K J; Touramanis, C

    2011-01-01

    Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a comprehensive study of the effects of electronegative impurity on gaseous and liquid argon scintillation light, an analysis of the efficacy of various purification chemicals, as well as the Liverpool LAr setup, which utilises a novel re-circulation purification system. Of the impurities tested - Air, O_2, H_2O, N_2 and CO_2 in the range of between 0.01 ppm to 1000 ppm - H_2O was found to have the most profound effect on gaseous argon scintillation light, and N_2 was found to have the least. Additionally, a correlation between the slow component decay time and the total energy deposited with 0.01 ppm - 100 ppm O_2 contamination levels in liquid argon has been established. The superiority of molecular sieves over anhydrous complexes at absorbing Ar gas, N_2 gas and H_2O vapou...

  15. ARGON RECOIL ION ELECTRON CAPTURE FROM NEUTRAL ARGON AND HELIUM STUDIED BY TIME RESOLVED V.U.V. SPECTROSCOPY

    OpenAIRE

    Lesteven-Vaisse, I.; Chantepie, M.; Folkmann, F.; Lecler, D.; Ben Sitel, A.

    1989-01-01

    Electron capture phenomena in recoil ion V.U.V. spectroscopy are tested through the evolution of the observed argon spectrum by introduction of helium in addition to argon in the collision chamber. Taking into account these mixed gas data by the time-differential method and using decay time analysis, an improved analysis of argon recoil ion V.U.V. radiation is presented.

  16. Argon laser-welded arteriovenous anastomoses.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; White, G; Lyons, R; Fujitani, R; Klein, S R; Uitto, J

    1987-11-01

    This study compared the healing of laser-welded and sutured canine femoral arteriovenous anastomoses. Arteriovenous fistulas 2 cm in length were created bilaterally in the femoral vessels of 10 dogs and were studied at 1 (n = 2), 2 (n = 2), 4 (n = 3), and 8 (n = 3) weeks. In each animal, one anastomosis (control) was closed with running 6-0 polypropylene sutures, and the contralateral anastomosis (experimental) was sealed with an argon laser (0.5 watt, 4 minutes of exposure, 1830 J/cm2/1 cm length of anastomosis). At removal all experimental anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 4 weeks revealed that laser-welded anastomoses had less inflammatory response and almost normal collagen and elastin reorientation. At 8 weeks sutured anastomoses had significant intimal hyperplasia whereas laser repairs had normal luminal architecture. Tensile strength and collagen production, measured by the synthesis of hydroxyproline and the steady-state levels of type I and type III procollagen messenger ribonucleic acids, at the anastomoses and in adjacent vein and artery specimens were similar in sutured and laser-welded repairs at 2, 4, and 8 weeks. We conclude that argon laser welding of anastomoses is an acceptable alternative to suture techniques, with the advantage of improved healing without foreign body response and possible diminished intimal hyperplasia at the anastomotic line. PMID:3312648

  17. Electron scattering and transport in liquid argon

    International Nuclear Information System (INIS)

    The transport of excess electrons in liquid argon driven out of equilibrium by an applied electric field is revisited using a multi-term solution of Boltzmann’s equation together with ab initio liquid phase cross-sections calculated using the Dirac-Fock scattering equations. The calculation of liquid phase cross-sections extends previous treatments to consider multipole polarisabilities and a non-local treatment of exchange, while the accuracy of the electron-argon potential is validated through comparison of the calculated gas phase cross-sections with experiment. The results presented highlight the inadequacy of local treatments of exchange that are commonly used in liquid and cluster phase cross-section calculations. The multi-term Boltzmann equation framework accounting for coherent scattering enables the inclusion of the full anisotropy in the differential cross-section arising from the interaction and the structure factor, without an a priori assumption of quasi-isotropy in the velocity distribution function. The model, which contains no free parameters and accounts for both coherent scattering and liquid phase screening effects, was found to reproduce well the experimental drift velocities and characteristic energies

  18. Pollution of liquid argon after neutron irradiation

    CERN Document Server

    Andrieux, M L; Collot, J; de Saintignon, P; Ferrari, A; Hostachy, J Y; Hoummada, A; Martin, P; Merkel, B; Puzo, P; Sauvage, D; Wielers, M

    2001-01-01

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem. (17 refs).

  19. Pollution of liquid argon after neutron irradiation

    International Nuclear Information System (INIS)

    The purpose of the neutron facility installed at SARA is to investigate the behavior of various materials to be used in the ATLAS liquid argon calorimeter, when submitted to fast neutron radiation. The samples are placed in a liquid argon cryostat a few cm away from the neutron source. Various pieces of the electromagnetic calorimeter have been tested in order to evaluate the rate of pollution of the liquid and consequently the possible signal loss in energy measurements. The average fluence was equivalent to the maximum expected in the calorimeter in about 10 years. The most striking feature of the results is that the pollution is not due to oxygen, at least for most of it. Using a particular value of the absorption length derived from these data, a simulation was carried out and the energy signal loss in the calorimeter could be predicted. Within the limits of our present knowledge, the conclusion is that damages due to this pollution will not be a problem

  20. Ion-beam excitation of liquid argon

    CERN Document Server

    Hofmann, M; Heindl, T; Neumeier, A; Oberauer, L; Potzel, W; Roth, S; Schönert, S; Wieser, J; Ulrich, A

    2015-01-01

    The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions, were used to excite liquid argon. Only minor differences were observed in the wavelength-spectra obtained with the different incident particles. Light emission in the wavelength range of the third excimer continuum was found to be strongly suppressed in the liquid phase. In time-resolved measurements, the time structure of the scintillation light can be directly attributed to wavelength in our studies, as no wavelength shifter has been used. These measurements confirm that the singlet-to-triplet intensity ratio in the second excimer continuum range is a useful parameter for particle discrimination, which can also be employed in wavelength-integrated measurements as long as the sensitivity of the detector system does not rise steeply for wavelengths longer than 190 nm. Using ou...

  1. Nitrogen Removal from Molten Steel under Argon DC Glow Plasma

    Institute of Scientific and Technical Information of China (English)

    SUN Ming-shan; DING Wei-zhong; LU Xiong-gang

    2005-01-01

    Under argon DC glow plasma, the nitrogen removal from molten steel was studied. The experimental result showed that nitrogen mass percent could be reduced to 0.000 8%. The change of polarity had no impact on nitrogen removal when the nitrogen mass percent was low. The mechanism of denitrogenation of molten steel under argon DC glow plasma was discussed.

  2. WARP: a double phase argon programme for dark matter detection

    International Nuclear Information System (INIS)

    WARP (Wimp ARgon Programme) is a double phase Argon detector for Dark Matter search under construction at Laboratori Nazionali del Gran Sasso. We present recent results obtained operating a prototype with a sensitive mass of 2.3 litres deep underground

  3. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.;

    1981-01-01

    By means of the Rutherford-backscattering method, the stopping cross section of solid argon has been measured for 0.5–3 MeV helium ions to an accuracy of not, vert, similar3%. The results agree within the experimental accuracies with our earlier measurements for gaseous argon over the energy region...

  4. Sodium chloride, potassium chloride, and virulence in Listeria monocytogenes.

    OpenAIRE

    MYERS, E. R.; Dallmier, A W; Martin, S E

    1993-01-01

    Virulence, as determined in a mouse model, and the virulence factor activities of catalase, superoxide dismutase, and listeriolysin O were examined in a parental strain (10403S) and in a nonhemolytic mutant strain (DP-L224) of Listeria monocytogenes. The cells were propagated in media containing various concentrations of sodium chloride or potassium chloride. Strains 10403S and DP-L224 exhibited significant increases in catalase activity and listeriolysin O activity when grown in medium conta...

  5. Commissioning of the ATLAS liquid argon calorimeters

    CERN Document Server

    Rezaie, Erfan

    ATLAS, a multi-purpose detector built at the LHC at CERN, requires an extensive commissioning campaign to be ready for proton-proton collisions. In this work, we focus on the commissioning of the liquid Argon (LAr) calorimeters, with emphasis on commissioning with cosmic rays. First we outline one phase of the commissioning work, which involves testing of the front-end electronics of the two endcap calorimeters. We then describe two cosmic ray generators as input to a Monte-Carlo simulation of cosmic rays in ATLAS, and compare their results. Finally, we explain a technique developed for this work which uses information from the Tile calorimeters to predict the timing of cosmic rays within the LAr calorimeters, because cosmic rays occur randomly in time whereas the electronics are clocked at [Special characters omitted.] . The results from this analysis tool are compared to default tools, using both simulated and real cosmic ray data in the calorimeters.

  6. Neutron Inelastic Scattering Study of Liquid Argon

    International Nuclear Information System (INIS)

    The inelastic scattering functions for liquid argon have been measured at 85.2 K. The coherent scattering function was obtained from a measurement on pure A-36 and the incoherent function was derived from the result obtained from the A-36 sample and the result obtained from a mixture of A-36 and A-40 for which the scattering is predominantly incoherent. The data, which are presented as smooth scattering functions at constant values of the wave vector transfer in the range 10 - 44/nm, are corrected for multiple scattering contributions and for resolution effects. Such corrections are shown to be essential in the derivation of reliable scattering functions from neutron scattering data. The incoherent data are compared to recent molecular dynamics results and the mean square displacement as a function of time is derived. The coherent data are compared to molecular dynamics results and also, briefly, to some recent theoretical models

  7. Large vessel sealing with the argon laser.

    Science.gov (United States)

    White, R A; Kopchok, G; Donayre, C; Lyons, R; White, G; Klein, S R; Pizzurro, D; Abergel, R P; Dwyer, R M; Uitto, J

    1987-01-01

    This study compared the histology, biochemistry, and tensile strength of laser-welded and sutured canine venotomies, arteriotomies, and arteriovenous fistulas. Twelve animals had bilateral femoral vessels studied, with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralateral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks (four animals for each type of repair), and were evaluated histologically by hematoxylin and eosin, elastin, and trichrome stains; biochemically by the formation of [3H]hydroxyproline as an index of collagen synthesis; and mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms, or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welding may be an alternative to sutures for repair of large-diameter venotomies, arteriotomies, and arteriovenous fistulas, as healing is comparable to that seen with suture repairs up to 4 weeks postoperatively. PMID:3306233

  8. Vascular Welding Using The Argon Laser

    Science.gov (United States)

    White, Rodney A.; Donayre, Carlos; Kopchok, George; White, Geoffrey; Abergel, R. Patrick; Lyons, Richard; Klein, Stanley; Dwyer, Richard; Uitto, Jouni

    1987-03-01

    This study compared the histology, biochemistry, and tensile strength of laser welded and sutured canine venotomies, arteriotomies and arteriovenous fistulas. Bilateral femoral, carotid or jugular vessels were studied with one repair (control) closed with interrupted 6-0 polypropylene sutures, and the contralatral repair (experimental) welded with the argon laser. Specimens were examined at weekly intervals from 1 to 4 weeks for each type of repair and evaluated histologically by hematoxylineosin, elastin and trichrome stains, biochemically by the formation of [3H] hyaroxyproline as an index of collagen synthesis, ana mechanically by tensile strength determinations. At removal, all experimental closures were patent without hematomas, aneurysms or luminal dilatation. Histologic and biochemical examination and tensile strength determinations suggest that laser welaing may be an alternative to sutures for repair of large diameter venotomies, arteriotomies and arteriovenous fistulas, as they heal comparable to suture repairs up to 4 weeks postoperatively.

  9. Ideas for future liquid Argon detectors

    International Nuclear Information System (INIS)

    We outline a strategy for future experiments on neutrino and astroparticle physics based on the use, at different detector mass scales (100 ton and 100 kton), of the liquid Argon Time Projection Chamber (LAr TPC) technique. The LAr TPC technology has great potentials for both cases with large degree of interplay between the two applications and a strong synergy. The ICARUS R and D programme has demonstrated that the technology is mature and that one can built a large (∼ 1 kton) LAr TPC. We believe that one can conceive and design a very large mass LAr TPC with a mass of 100 kton by employing a monolithic technology based on the use of industrial, large volume cryogenic tankers developed by the petro-chemical industry. We show a potential implementation of a large LAr TPC detector. Such a detector would be an ideal match for a Superbeam[New J. Phys. 4 (2002) 88 [arXiv:hep-ph/0208047

  10. Liquid-argon cylindrical pulsed ionization chamber

    International Nuclear Information System (INIS)

    A liquid-argon cylindrical ionization chamber with a working volume of 200 cm2 is described. The chamber anode is made of stainless steel in the form of a hollow cylinder 30 mm in diameter and 140 mm in length. A beryllium bronze wire in diameter of 0.1 mm and at a spacing of 1 mm is used for winding the chamber screen grid. The chamber cathode is a brass thin-walled cylinder having an internal diameter of 56 mm and a height of 156 mm. The cathode-grid gap is 10 mm, the cathode-case gap is 2 mm. A 0.5 l cooling bath filled with liquid nitrogen is used to refrigirate the chamber. The chamber is evacuated to about 10-5 mm Hg. The total concentration of electronegative impurities in argon does not exceed 6x10-9. Dependences of the chamber counting and amplitude responses, on the cathode voltage under irradiation with γ-quanta at energies of 0.898 MeV and 1.836 MeV are given. The value of the energy resolution was evaluated by differentiating the high-energy edge of the Compton spectrum. The total width at a peak half-height constitutes 5% for an electron energy of 1.612 MeV. To achieve better resolution of the chamber it is necessary to reduce preamplifier noises by three times, to increase the working gap of the chamber and decrease the grid-anode gap

  11. Formation of argon-boron bonds in the reactions of BFn+/2+ cations with neutral argon

    Czech Academy of Sciences Publication Activity Database

    Levee, L.; Calogero, C.; Barbieri, E.; Byrne, S.; Donahue, C.; Eisenberg, M.; Hattenbach, S.; Le, J.; Capitani, J. F.; Roithová, J.; Schröder, Detlef

    2012-01-01

    Roč. 323, 1 Jun (2012), s. 2-7. ISSN 1387-3806 R&D Projects: GA ČR GA203/09/1223 Grant ostatní: European Research Council(XE) AdG HORIZOMS Institutional support: RVO:61388963 Keywords : argon compound * boron fluoride * dication * gas phase reactivity * mass spectrometry * neon compound Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.142, year: 2012

  12. Chloride channels in stroke

    Institute of Scientific and Technical Information of China (English)

    Ya-ping ZHANG; Hao ZHANG; Dayue Darrel DUAN

    2013-01-01

    Vascular remodeling of cerebral arterioles,including proliferation,migration,and apoptosis of vascular smooth muscle cells (VSMCs),is the major cause of changes in the cross-sectional area and diameter of the arteries and sudden interruption of blood flow or hemorrhage in the brain,ie,stroke.Accumulating evidence strongly supports an important role for chloride (Clˉ) channels in vascular remodeling and stroke.At least three Clˉ channel genes are expressed in VSMCs:1) the TMEM16A (or Ano1),which may encode the calcium-activated Clˉ channels (CACCs); 2) the CLC-3 Clˉ channel and Clˉ/H+ antiporter,which is closely related to the volume-regulated Clˉ channels (VRCCs); and 3) the cystic fibrosis transmembrane conductance regulator (CFTR),which encodes the PKA-and PKC-activated Clˉ channels.Activation of the CACCs by agonist-induced increase in intracellular Ca2+ causes membrane depolarization,vasoconstriction,and inhibition of VSMC proliferation.Activation of VRCCs by cell volume increase or membrane stretch promotes the production of reactive oxygen species,induces proliferation and inhibits apoptosis of VSMCs.Activation of CFTR inhibits oxidative stress and may prevent the development of hypertension.In addition,Clˉ current mediated by gammaaminobutyric acid (GABA) receptor has also been implicated a role in ischemic neuron death.This review focuses on the functional roles of Clˉ channels in the development of stroke and provides a perspective on the future directions for research and the potential to develop Clˉ channels as new targets for the prevention and treatment of stroke.

  13. The effect of storage in damp air and damp argon on pond water contaminated CAGR fuel cladding steels

    International Nuclear Information System (INIS)

    Retention of the mechanical integrity of fuel element assemblies during dry storage forms part of the strategy for any dry-store and is important for the ease of eventual reprocessing or disposal. This report describes a number of corrosion experiments which have been carried out on coupons of unirradiated CAGR fuel cladding steel which have been contaminated with simulated pond water. Two potential dry-store problem areas have been addressed. First is the possibility of failure of the dry-store mild steel container, allowing damp air to replace the nominally dry argon cover gas. Second is the possibility of water-logged failed fuel being inadvertently containerised giving rise to a humid argon atmosphere within the dry-store container. Specimens of niobium stabilised and titanium nitride strengthened CAGR fuel cladding steels in virgin, pre-oxidised and laboratory sensitised states have been exposed at temperatures of 1500C and 4000C, to air saturated with water at 100C and to argon saturated at 250C. Most specimens were contaminated with simulated pond water deposits containing chloride anion concentrations up to 10 ppm. No deleterious effects were observed either gravimetrically or metallographically after exposures between 10039 hours and 13152 hours. However, the absence of stress and radiation in these experiments means that caution should be exercised in applying the results to situations in which those conditions are present. (author)

  14. Argon laser induced changes to the carbonate content of enamel

    Energy Technology Data Exchange (ETDEWEB)

    Ziglo, M.J. [Orthodontic Graduate Program, Faculty of Medicine and Dentistry, University of Alberta, Private Practice, Regina, Saskatchewan (Canada); Nelson, A.E., E-mail: aenelson@dow.com [Department of Chemical and Materials Engineering, Faculty of Engineering, University of Alberta (Canada); Heo, G.; Major, P.W. [Orthodontic Graduate Program, Faculty of Medicine and Dentistry, University of Alberta (Canada)

    2009-05-15

    Argon laser irradiation can be used to cure orthodontic brackets onto teeth in significantly less time than conventional curing lights. In addition, it has been shown that the argon laser seems to impart a demineralization resistance to the enamel. The purpose of this study was to use surface science techniques to ascertain if this demineralization resistance is possibly a result of a decrease in the carbonate content of enamel. Eleven mandibular third molars previously scheduled for extraction were collected and used in the present study. The teeth were sectioned in two and randomly assigned to either the argon laser (457-502 nm; 250 mW cm{sup -2}) or the control (no treatment) group. The sections assigned to the argon laser group were cured for 10 s and analyzed. To exaggerate any potential changes the experimental sections were then exposed to a further 110 s of argon laser irradiation. Surface analysis was performed using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results showed no statistically significant change in the carbonate content of enamel after argon laser irradiation (p > 0.05). Thus, it is suggested that any demineralization resistance imparted to the enamel surface by argon laser irradiation is not due to alterations in carbonate content.

  15. Argon laser induced changes to the carbonate content of enamel

    International Nuclear Information System (INIS)

    Argon laser irradiation can be used to cure orthodontic brackets onto teeth in significantly less time than conventional curing lights. In addition, it has been shown that the argon laser seems to impart a demineralization resistance to the enamel. The purpose of this study was to use surface science techniques to ascertain if this demineralization resistance is possibly a result of a decrease in the carbonate content of enamel. Eleven mandibular third molars previously scheduled for extraction were collected and used in the present study. The teeth were sectioned in two and randomly assigned to either the argon laser (457-502 nm; 250 mW cm-2) or the control (no treatment) group. The sections assigned to the argon laser group were cured for 10 s and analyzed. To exaggerate any potential changes the experimental sections were then exposed to a further 110 s of argon laser irradiation. Surface analysis was performed using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The results showed no statistically significant change in the carbonate content of enamel after argon laser irradiation (p > 0.05). Thus, it is suggested that any demineralization resistance imparted to the enamel surface by argon laser irradiation is not due to alterations in carbonate content.

  16. LArGe - A liquid argon scintillation veto for GERDA

    OpenAIRE

    Heisel, M.(Max-Planck-Institut für Kernphysik, Heidelberg, Germany)

    2011-01-01

    LArGe is a Gerda low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the Gerda experiment. Gerda searches for the neutrinoless double-beta decay in 76Ge, by operating naked germanium detectors submersed into 65 m3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used...

  17. Practical reactor production of {sup 41}Ar from argon clathrate

    Energy Technology Data Exchange (ETDEWEB)

    Mercer, J.R. E-mail: jmercer@pharmacy.ualberta.ca; Duke, M.J.M.; McQuarrie, S.A

    2000-06-01

    The radionuclide {sup 41}Ar has many ideal properties as a gas flow tracer. However, the modest cross-section of {sup 40}Ar for thermal neutron activation makes preparation of suitable activities of {sup 41}Ar technically difficult particularly for low flux reactors. Argon can however be trapped in a molecular complex called a clathrate that can then be irradiated. We prepared argon clathrate and explored its irradiation and stability characteristics. Argon clathrate can be used to provide gigabecquerel quantities of {sup 41}Ar even with low power reactors.

  18. Membrane separation processes for argon plasma gas recovery

    OpenAIRE

    Harlacher, Thomas

    2014-01-01

    A mixture of argon and hydrogen is used as plasma gas in a thermal plasma synthesis for the production of silicon carbide. Next to argon and hydrogen, the exhaust gas of the ceramic synthesis contains carbon monoxide. Since argon is an expensive gas, the plasma gas needs to be recycled. For this purpose, the carbon monoxide has to be removed from the exhaust gas. The applicability of a membrane based gas separation process for this separation task was investigated in this study. A process rou...

  19. Stopping Power of Solid Argon for Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Grauersen, O.; Hansen, Jens Leonhart; Sørensen, H.

    1981-01-01

    By means of the Rutherford-backscattering method, the stopping cross section of solid argon has been measured for 0.5–3 MeV helium ions to an accuracy of not, vert, similar3%. The results agree within the experimental accuracies with our earlier measurements for gaseous argon over the energy region...... studied. This proves that the gas/solid difference for argon predicted in recent stopping-power tabulations is significantly overestimated. With high-order Z1 correction terms included in the theoretical description, calculated shell corrections based on the Lindhard-Scharff model are in good agreement...

  20. Technical Note: Could benzalkonium chloride be a suitable alternative to mercuric chloride for preservation of seawater samples?

    Directory of Open Access Journals (Sweden)

    J. Gloël

    2015-08-01

    Full Text Available Instrumental equipment unsuitable or unavailable for fieldwork as well as lack of ship space can necessitate the preservation of seawater samples prior to analysis in a shore-based laboratory. Mercuric chloride (HgCl2 is routinely used for such preservation, but its handling and subsequent disposal incur significant risks and expense. Benzalkonium chloride (BAC has been used previously for freshwater samples. Here, we assess BAC as a less hazardous alternative microbial inhibitor for marine samples prior to the measurement of oxygen-to-argon (O2/Ar ratios, as used for the determination of plankton net community production. BAC at a concentration of 50 mg dm−3 inhibited microbial activity for at least three days in seawater with chlorophyll a (Chl a concentrations up to 1 mg m−3, possibly longer when Chl a concentrations were lower. BAC concentrations of 100 and 200 mg dm−3 were no more effective than 50 mg dm−3. With fewer risks to human health and the environment, and no requirement for expensive waste disposal, BAC could be a viable alternative to HgCl2 for short-term preservation of seawater samples, but is not a replacement for HgCl2 in the case of oxygen triple isotope analysis, which requires storage over weeks to months. In any event, further tests on a case-by-case basis should be undertaken if use of BAC was considered, since its inhibitory activity may depend on concentration and composition of the microbial community.

  1. Technical note: Could benzalkonium chloride be a suitable alternative to mercuric chloride for preservation of seawater samples?

    Science.gov (United States)

    Gloël, J.; Robinson, C.; Tilstone, G. H.; Tarran, G.; Kaiser, J.

    2015-12-01

    Instrumental equipment unsuitable or unavailable for fieldwork as well as lack of ship space can necessitate the preservation of seawater samples prior to analysis in a shore-based laboratory. Mercuric chloride (HgCl2) is routinely used for such preservation, but its handling and subsequent disposal incur environmental risks and significant expense. There is therefore a strong motivation to find less hazardous alternatives. Benzalkonium chloride (BAC) has been used previously as microbial inhibitor for freshwater samples. Here, we assess the use of BAC for marine samples prior to the measurement of oxygen-to-argon (O2 / Ar) ratios, as used for the determination of biological net community production. BAC at a concentration of 50 mg dm-3 inhibited microbial activity for at least 3 days in samples tested with chlorophyll a (Chl a) concentrations up to 1 mg m-3. BAC concentrations of 100 and 200 mg dm-3 were no more effective than 50 mg dm-3. With fewer risks to human health and the environment, and no requirement for expensive waste disposal, BAC could be a viable alternative to HgCl2 for short-term preservation of seawater samples, but is not a replacement for HgCl2 in the case of oxygen triple isotope analysis, which requires storage over weeks to months. In any event, further tests on a case-by-case basis should be undertaken if use of BAC was considered, since its inhibitory activity may depend on concentration and composition of the microbial community.

  2. Argon laser treatment of urethral stricture and vesical neck contracture.

    Science.gov (United States)

    Adkins, W C

    1988-01-01

    The physical characteristics of the argon laser wavelength allow a precise incision with excellent hemostasis and negligible heating of adjacent tissues resulting in less scarring. These qualities are used to advantage in the treatment of strictures. The argon laser was used to perform 13 internal urethrotomies and ten vesical neck incisions. The operative method used is similar to optical internal urethrotomy. The argon probe incises hemostatically, reducing the need for extensive fulguration of tissues at the operative site and thereby reducing the tendency for more scar tissue to form and compromise the operation. The same hemostasis reduces the need for postoperative indwelling urethral catheterization. Utility of the argon device in most instances allows treatment to be conducted on an outpatient basis without general anesthesia and without use of postoperative urethral catheters, yielding an effective, cost-saving therapy. PMID:3210887

  3. Evidence of electric breakdown induced by bubbles in liquid argon

    CERN Document Server

    Bay, F; Murphy, S; Resnati, F; Rubbia, A; Sergiampietri, F; Wu, S

    2014-01-01

    We report on the results of a high voltage test in liquid argon in order to measure its dielectric rigidity. Under stable conditions and below the boiling point, liquid argon was found to sustain a uniform electric field of 100 kV/cm, applied in a region of 20 cm$^2$ area across 1 cm thick gap. When the liquid is boiling, breakdowns may occur at electric fields as low as 40 kV/cm. This test is one of the R&D efforts towards the Giant Liquid Argon Charge Imaging ExpeRiment (GLACIER) as proposed Liquid Argon Time Projection Chamber (LAr TPC) for the LBNO observatory for neutrino physics, astrophysics and nucleon decay searches.

  4. Excitation temperatures of atmospheric argon in dielectric barrier discharges

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yu; Wen Xiaohui; Yang Weihong [CAS Key Laboratory of Basic Plasma Physics and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2007-08-15

    A method for the determination of excitation temperatures based on optical emission spectroscopy and Fermi-Dirac distribution was set up and experiments were performed on atmospheric argon dielectric barrier discharges. Local thermodynamic equilibrium was proved to exist in the discharge and the validity of Boltzmann distribution is discussed. The main aim of this paper is to obtain the temperatures of atmospheric Ar II as a function of the discharge voltage, discharge frequency, argon flow rate and the argon fraction. It was found that the excitation temperatures are in the range 3800-4950 K. Besides, an increase in the argon flow rate resulting in a slight growth of the temperature and the add-in of air leading to the decrease in temperature was observed.

  5. The Effects of Dissolved Methane upon Liquid Argon Scintillation Light

    CERN Document Server

    Jones, B J P; Back, H O; Collin, G; Conrad, J M; Greene, A; Katori, T; Pordes, S; Toups, M

    2013-01-01

    In this paper we report on measurements of the effects of dissolved methane upon argon scintillation light. We monitor the light yield from an alpha source held 20 cm from a cryogenic photomultiplier tube (PMT) assembly as methane is injected into a high-purity liquid argon volume. We observe significant suppression of the scintillation light yield by dissolved methane at the 10 part per billion (ppb) level. By examining the late scintillation light time constant, we determine that this loss is caused by an absorption process and also see some evidence of methane-induced scintillation quenching at higher concentrations (50-100 ppb). Using a second PMT assembly we look for visible re-emission features from the dissolved methane which have been reported in gas-phase argon methane mixtures, and we find no evidence of visible re-emission from liquid-phase argon methane mixtures at concentrations between 10 ppb and 0.1%.

  6. The ATLAS Liquid Argon Calorimeter Construction, Integration, Commissioning

    CERN Document Server

    Aleksa, Martin

    2006-01-01

    The ATLAS liquid argon (LAr) calorimeter system consists of an electromagnetic barrel calorimeter and two end caps with electromagnetic, hadronic and forward calorimeters. The liquid argon sampling technique, with an accordion geometry was chosen for the barrel electromagnetic calorimeter (EMB) and adapted to the end cap (EMEC). The hadronic end cap calorimeter (HEC) uses a copper-liquid argon sampling technique with flat plate geometry and is subdivided in depth in two wheels per end-cap. Finally, the forward calorimeter (FCAL) is composed of three modules employing cylindrical electrodes with thin liquid argon gaps. The construction of the full calorimeter system is complete since mid-2004. Production modules constructed in the home institutes were integrated into wheels at CERN in 2003-2004, and inserted into the three cryostats. They passed their first complete cold test before the lowering into the ATLAS cavern. Results of quality checks (e.g. electrical, mechanical, ...) performed on all the 190304 read...

  7. Size Determination of Argon Clusters from a Rayleigh Scattering Experiment

    Institute of Scientific and Technical Information of China (English)

    LEI An-Le; ZHAI Hua-Jin; LIU Bing-Chen; LI Zhong; NI Guo-Yuan; XU Zhi-Zhan

    2000-01-01

    Argon clusters are produced in the process of adiabatic expansion of a high backing pressure gas into vacuum through a nozzle. The cluster size is determined by a Rayleigh scattering measurement. The scattered signal measured is proportional to the 2.78th power of gas stagnation pressure. The average cluster sizes vary from 100 to more than 12000 atoms/cluster with the argon gas backing pressures ranging between 3 to 45 atm.

  8. A purity monitoring system for liquid argon calorimeters

    International Nuclear Information System (INIS)

    For liquid argon calorimeters electronegative impurities dissolved in the medium degrade the detector response and deteriorate the energy resolution, especially at high energies. A concept for a purity monitoring system for liquid argon calorimeters has been developed and is presented here. Special combined monitors of 241Am- and 207Bi-cells are used to monitor the concentration of impurities. The working principle as well as results from test measurements are discussed

  9. Studies of Electron Avalanche Behavior in Liquid Argon

    OpenAIRE

    Kim, J.G.; Dardin, S. M.; Jackson, K.H.; Kadel, R. W.(Lawrence Berkeley National Laboratory and University of California, 94720, Berkeley, California, USA); Kadyk, J. A.; Peskov, V.; Wenzel, W. A.

    2002-01-01

    Electron avalanching in liquid argon is being studied as a function of voltage, pressure, radiation intensity, and the concentrations of certain additives, especially xenon. The avalanches produced in an intense electric field at the tip of a tungsten needle are initiated by ionization from a moveable americium (241Am) gamma ray source. Photons from xenon excimers are detected as photomultiplier signals in coincidence with the current pulse from the needle. In pure liquid argon the avalanche ...

  10. Pulse shape discrimination studies in a liquid Argon scintillation detector

    OpenAIRE

    Pollmann, T.

    2007-01-01

    Liquid rare gases have been gaining popularity as detector media in rare event searches, especially dark matter experiments, and one factor driving their adoption is the possibility to recognise different types of ionizing radiation by the pulse shapes they evoke. This work on pulse shape discrimination in a liquid argon scintillation detector was done in the framework of the GERDA experiment, where liquid argon scintillation signals may be used for background suppression purposes. Liquid arg...

  11. RF-ARGON PLASMA INDUCED SURFACE MODIFICATION OF PAPER

    OpenAIRE

    HALIL TURGUT SAHIN

    2008-01-01

    The radio frequency (RF) argon plasma induced surface modification of paper revealed novel surface characteristics and substantially changed surface topography. It was found that RF-argon glow discharge affects surface properties resulting in photo-degradation and chain-scission mechanism on paper network structure. High-power and extended treatment time caused increasing elemental carbon, while decreasing the oxygen concentration on paper surface. However, increased hydroxyls and the creatio...

  12. Chloride in vesicular trafficking and function.

    Science.gov (United States)

    Stauber, Tobias; Jentsch, Thomas J

    2013-01-01

    Luminal acidification is of pivotal importance for the physiology of the secretory and endocytic pathways and its diverse trafficking events. Acidification by the proton-pumping V-ATPase requires charge compensation by counterion currents that are commonly attributed to chloride. The molecular identification of intracellular chloride transporters and the improvement of methodologies for measuring intraorganellar pH and chloride have facilitated the investigation of the physiology of vesicular chloride transport. New data question the requirement of chloride for pH regulation of various organelles and furthermore ascribe functions to chloride that are beyond merely electrically shunting the proton pump. This review surveys the currently established and proposed intracellular chloride transporters and gives an overview of membrane-trafficking steps that are affected by the perturbation of chloride transport. Finally, potential mechanisms of membrane-trafficking modulation by chloride are discussed and put into the context of organellar ion homeostasis in general. PMID:23092411

  13. Stability of succinylcholine chloride injection.

    Science.gov (United States)

    Schmutz, C W; Mühlebach, S F

    1991-03-01

    The stability of succinylcholine chloride injection prepared by a hospital pharmacy was studied under a wide variety of conditions. Batches of succinylcholine chloride injection 10 mg/mL containing sodium chloride, methyl-4-hydroxybenzoate, hydrochloric acid, and water were prepared. Samples were tested for the effect of initial pH (3.0 and 4.2) and sterilization (steam treatment at 100 degrees C for 30 minutes and 121 degrees C for 20 minutes) on stability after three weeks; long-term stability under refrigeration (12, 17, and 23 months of storage at 4 degrees C); and the effect of storage temperature (4-6 degrees C, 20-26 degrees C, 35 degrees C, and 70 degrees C) and light exposure at various intervals up to 12 months. Samples were analyzed by thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC). Unlike heating at 121 degrees C, heating at 100 degrees C produced no significant loss of succinylcholine chloride, independent of the initial pH. Succinylcholine chloride was hydrolyzed only minimally over 23 months if the solution was stored at 4-6 degrees C. A 10% loss of drug content occurred if solutions were kept at 20-26 degrees C for five months, at 35 degrees C for one month, or at 70 degrees C for one day. Initial degradation was slowed if the solution was protected from light. The assessments by TLC proved to be more sensitive than the HPLC measurements. Succinylcholine chloride injection sterilized at 100 degrees C for 30 minutes can be stored for up to five months at room temperature if protected from light. The preparation is stable for at least two years under refrigeration. PMID:2028996

  14. Chloride binding of cement-based materials subjected to external chloride environment - A review

    OpenAIRE

    Yuan, Q.; Shi, C; Schutter, G. de; Audenaert, K.; Deng, D.

    2009-01-01

    This paper reviews the chloride binding of cement-based materials subjected to external chloride environments. Chloride ion exist either in the pore solution, chemically bound to the hydration products, or physically held to the surface of the hydration products. Chloride binding of cement-based material is very complicated and influenced by many factors, such as chloride concentration, cement composition, hydroxyl concentration, cation of chloride salt, temperature, supplementary cementing m...

  15. Energy resolution for α-particles in doped liquid argon

    International Nuclear Information System (INIS)

    The report describes experiments on the effect of allene doped in liquid argon. In the case of doped argon, a large amount of charge is obtained even at low electric fields and the measured charge increases with the field gradually. This can be explained as follows; part of deposited energy which does not form charge in pure argon contributes to charge signal in doped argon through scintillation photons which ionize allene molecules. The main factors determining the energy resolution for α-particles are considered to be (1) fluctuation in the number of produced ion-electron pairs as expressed by the Fano factor, (2) fluctuation in recombination process, (3) fluctuation in photoionization, (4) fluctuation due to the condition of radioactive source and surface of electrodes, (5) fluctuation in geometrical efficiency due to the range and emission angle of α-particles in liquid argon, and (6) electronic noise of amplifier. The factors (1) and (3) can be neglected because of a large number of associated electrons or photons. In pure liquid argon, the factor (2) may be a cause of bad resolution since the fraction of the produced ion-electron paris which do not recombine is small and the photoionization process never occurs for photons emitted through recombination. (N.K.)

  16. Power Consideration for Pulsed Discharges in Potassium Seeded Argon

    Institute of Scientific and Technical Information of China (English)

    XIA Sheng-Guo; HE Jun-Jia; LIU Ke-Fu

    2007-01-01

    Minimization of energy consumed in plasma generation is critical for applications, in which a large volume of plasmas is needed. We suggest that a high electron density atmospheric pressure plasmas can be generated by pulsed discharges in potassium seeded argon at an elevated temperature with a very small power input. The ionization efficiency and power budget of pulsed discharges in such plasmas are analytically studied. The results show that ionization efficiency of argon, especially at small reduced electric field E/N (the ratio of the electric field to the gas number density), is improved effectively in the presence of small amount of potassium additives. Power input of pulsed discharge to sustain a prescribed average level of ionization in potassium seeded argon is three orders of magnitude lower than that in pure argon. Further, unlike in pure argon, it is found that very short high-voltage pulses with very high repetition rates are unnecessary in potassium seeded argon. A pulse with 100ns of pulse duration, 5kHz of repetition rate, and 2Td (1 Td = 1 ×10-21 Vm2) of E/N is enough to sustain an electron density of 10l9m-3 in 1 atm 1500 K Ar+0.1% K mixture, with a very small power input of about 0.08 × 104 W/m3.

  17. Electron densities and energies of a guided argon streamer in argon and air environments

    International Nuclear Information System (INIS)

    In this study we report the temporally and spatially resolved electron densities and mean energies of a guided argon streamer in ambient argon and air obtained by Thomson laser scattering. The plasma is driven by a positive monopolar 3.5 kV pulse, with a pulse width of 500 ns and a frequency of 5 kHz which is synchronized with the high repetition rate laser system. This configuration enables us to use the spatial and temporal stability of the guided streamer to accumulate a multitude of laser/plasma shots by a triple grating spectrometer equipped with an ICCD camera and to determine the electron parameters. We found a strong initial ne-overshoot with a maximum of 7 × 1019 m−3 and a mean electron energy of 4.5 eV. This maximum is followed by a fast decay toward the streamer channel. Moreover, a 2D distribution of the electron density is obtained which exhibits a peculiar mushroom-like shape of the streamer head with a diameter significantly larger than that of the emission profile. A correlation of the width of the streamer head with the expected pre-ionization channel is found. (paper)

  18. 1,5-Diaminotetrazolium chloride

    Directory of Open Access Journals (Sweden)

    Ling-Qiao Meng

    2010-04-01

    Full Text Available The title compound, CH5N6+·Cl−, crystallized with two indepedent 1,5-diaminotetrazolium cations and two independent chloride anions in the asymmetric unit. In the crystal, there are a number of N—H...Cl hydrogen-bonding interactions, which generate a three-dimensional network.

  19. New argon-argon (40Ar/39Ar) radiometric age dates from selected subsurface basalt flows at the Idaho National Laboratory, Idaho

    Science.gov (United States)

    Hodges, Mary K.; Turrin, Brent D.; Champion, Duane E.; Swisher, Carl C., III

    2015-01-01

    In 2011, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collected samples for 12 new argon-argon radiometric ages from eastern Snake River Plain olivine tholeiite basalt flows in the subsurface at the Idaho National Laboratory. The core samples were collected from flows that had previously published paleomagnetic data. Samples were sent to Rutgers University for argon-argon radiometric dating analyses.

  20. Evolution of Martian atmospheric argon: Implications for sources of volatiles

    Science.gov (United States)

    Hutchins, Kevin S.; Jakosky, Bruce M.

    We have examined processes affecting isotopes of argon (36Ar, 38Ar, 40Ar) in order to determine important atmospheric sources and sinks. Our simple model for argon evolution incorporates production of radiogenic argon in the mantle, outgassing of all argon species by extrusive and intrusive volcanism, and loss to space by knock-on sputtering above the exobase. Sputtering has been shown previously to be an important loss process for atmospheric species, especially isotopes of noble gases, which have few other mechanisms of escape. The integrated evolution of argon (36Ar, 38Ar, and 40Ar, respectively) is modeled in terms of these variables: (1) the planetary concentration of potassium, (2) the fraction of juvenile argon released catastrophically during the first 600 Myr., (3) potential variation in the time-history of sputtering loss from that suggested by Luhmann et al. [1992], and (4) the volume of total outgassing to the surface as compared to outgassing contributed by volcanic release. Our results indicate that Mars has lost between 85-95% of 36Ar and 70-88% of outgassed 40Ar. Due to this substantial loss, the planet must have outgassed the equivalent of between 10 and 100 times the total volume of gases released by extrusive and intrusive volcanics. This indicates that volcanic outgassing, alone, is insufficient to explain the present-day abundances of 36Ar and 40Ar in the Martian atmosphere. Similar calculations for 20Ne suggest outgassed volumes of between 100 and 1800 times in excess of that due to volcanism. This results in a distinct Ne/Ar elemental fractionation, with a preference for outgassing argon, of the order of 10 to 17. Although the results must be evaluated within the model uncertainties, the results are compelling in that they unequivocally show the existence of additional sources of atmospheric volatiles and helps define a means to identify them.

  1. Progress of Carbonation in Chloride Contaminated Concretes

    OpenAIRE

    Wang, Yaocheng; Basheer, P.A.M.; Nanukuttan, S; Bai, Y.

    2016-01-01

    Concretes used in marine environment are generally under the cyclic effect of CO2 and chloride ions (Cl-). To date, the influence of carbonation on ingress of chloride ions in concretes has been widely studied; in comparison, study on the influence of Cl- on the progress of carbonation is limited. During the study, concretes were exposed to independent and combined mechanisms of carbonation and chloride ingress regimes. Profiles of apparent pH and chloride concentration were used to indicate ...

  2. Chloride sublimation of gold-arsenic concentrates

    International Nuclear Information System (INIS)

    Present article is devoted to chloride sublimation of gold-arsenic concentrates. The results of studies of chloride sublimation of gold-arsenic comprising concentrates of Chore deposit of Tajikistan are considered. It is found that by application sodium chloride for gold-arsenic comprising concentrates it is possible to extract gold and silver from flotation concentrates.

  3. 21 CFR 582.5446 - Manganese chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Manganese chloride. 582.5446 Section 582.5446 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5446 Manganese chloride. (a) Product. Manganese chloride. (b) Conditions of use....

  4. Characterisation of GERDA Phase-I detectors in liquid argon

    International Nuclear Information System (INIS)

    GERDA will search for neutrinoless double beta decay in 76Ge by submerging bare enriched HPGe detectors in liquid argon. In GERDA Phase-I, reprocessed enriched-Ge detectors, which were previously operated by the Heidelberg-Moscow and IGEX collaborations, and reprocessed natural-Ge detectors from Genius-TF, will be redeployed. We have tested the operation and performance of bare HPGe detectors in liquid nitrogen and in liquid argon over more than three years with three non-enriched p-type prototype detectors. The detector handling and mounting procedures have been defined and the Phase-I detector technology, the low-mass assembly and the long-term stability in liquid argon have been tested successfully. The Phase-I detectors were reprocessed by Canberra Semiconductor NV, Olen, according to their standard technology but without the evaporation of a passivation layer. After their reprocessing, the detectors have been mounted in their low-mass holders and their characterisation in liquid argon performed. The leakage current, the counting characteristics and the efficiency of the detectors have been measured. The testing of the detectors was carried out in the liquid argon test stand of the GERDA underground Detector Laboratory (GDL) at LNGS. The detectors are now stored underground under vacuum until their operation in GERDA.

  5. Argon-40: Excess in submarine pillow basalts from Kilauea Volcano, Hawaii

    Science.gov (United States)

    Brent, Dalrymple G.; Moore, J.G.

    1968-01-01

    Submarine pillow basalts from Kilauea Volcano contain excess radiogenic argon-40 and give anomalously high potassium-argon ages. Glassy rims of pillows show a systematic increase in radiogenic argon-40 with depth, and a pillow from a depth of 2590 meters shows a decrease in radiogenic argon-40 inward from the pillow rim. The data indicate that the amount of excess radiogenic argon-40 is a direct function of both hydrostatic pressure and rate of cooling, and that many submarine basalts are not suitable for potassium-argon dating.

  6. Metastable argon beam source using a surface wave sustained plasma

    International Nuclear Information System (INIS)

    A new source of metastable argon atoms in the thermal energy range is reported. The source is based on expanding a plasma sustained by electromagnetic surface waves in a quartz tube through a converging nozzle and extracting a beam from the supersonic free-expansion jet. The beam was characterized by time-of-flight measurements which yielded the absolute intensity and velocity distribution of the argon metastables. The source produced a maximum intensity of 6.2x1014 metastables per second per steradian, the highest time-averaged intensity of thermal argon metastables of any source reported to date. A simple picture of an expanding plasma in a recombination regime is used to explain the dependence of the metastable intensity on absorbed power

  7. On the electric breakdown in liquid argon at centimeter scale

    Science.gov (United States)

    Auger, M.; Blatter, A.; Ereditato, A.; Goeldi, D.; Janos, S.; Kreslo, I.; Luethi, M.; von Rohr, C. Rudolf; Strauss, T.; Weber, M. S.

    2016-03-01

    We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  8. Pressure regulation in the dry-boxes. Argon purification

    International Nuclear Information System (INIS)

    Each dry-box is equipped with an autonomous installation for circulation and purification of argon and for pressure regulation. This installation consists essentially of a ballast tank, a compressor and two valves electromagnetically controlled by a contact manometer. The compressor and the valves are enclosed in the tank to form a system as compact as possible. The argon is purified by passing it over a furnace filled with titanium-zirconium turnings brought to about 800 deg. C, branching off the main system. With this set-up as well as the automatic maintenance of a constant depression in the box, a quality of argon is obtained whose oxygen contact is undetectable by the manganous hydroxide method. (author)

  9. Bacteria Inactivation Using DBD Plasma Jet in Atmospheric Pressure Argon

    International Nuclear Information System (INIS)

    A coaxial dielectric barrier discharge plasma jet was designed, which can be operated in atmospheric pressure argon under an intermediate frequency sinusoidal resonant power supply, and an atmospheric pressure glow-like discharge was achieved. Two kinds of typical bacteria, i.e., the Staphylococcus aureus (S. aureus) and Escherichia coil (E. coil), were employed to study the bacterial inactivation mechanism by means of the non-thermal plasma. The killing log value (KLV) of S. aureus reached up to 5.38 with a treatment time of 90 s and that of E. coil up to 5.36 with 60 s, respectively. According to the argon emission spectra of the plasma jet and the scanning electron microscope (SEM) images of the two bacteria before and after the plasma treatment, it is concluded that the reactive species in the argon plasma played a major role in the bacterial inactivation, while the heat, electric field and UV photons had little effect. (plasma technology)

  10. Energy resolution studies of liquid argon ionization detectors

    International Nuclear Information System (INIS)

    A gridded ionization chamber was used to study the energy resolution in liquid argon with electrons from a 207Bi radioactive source. Argon was purified in the gas phase with a simple and reliable system, capable of reducing the impurity level below 1 ppb O2 equivalent, as inferred by a pulse shape analysis of the ionization signals. The electron spectrum was measured at different drift fields, up to 10.9 KV/cm. At this maximum field, a total energy resolution of 32 keV (fwhm), corresponding to a noise-subtracted energy resolution of 26 keV (fwhm), was obtained for the 976 keV conversion electron line. This value is the best reported so far in liquid argon but is still a factor of seven worse than the theoretical limit set by the Fano factor. The reasons for this discrepancy are discussed. (orig.)

  11. Attenuation measurements of vacuum ultraviolet light in liquid argon revisited

    CERN Document Server

    Neumeier, A; Himpsl, A; Hofmann, M; Oberauer, L; Potzel, W; Schönert, S; Ulrich, A

    2015-01-01

    The attenuation of vacuum ultraviolet light in liquid argon in the context of its application in large liquid noble gas detectors has been studied. Compared to a previous publication several technical issues concerning transmission measurements in general are addressed and several systematic effects were quantitatively measured. Wavelength-resolved transmission measurements have been performed from the vacuum ultraviolet to the near-infrared region. On the current level of sensitivity with a length of the optical path of 11.6 cm, no xenon-related absorption effects could be observed, and pure liquid argon is fully transparent down to the short wavelength cut-off of the experimental setup at 118 nm. A lower limit for the attenuation length of pure liquid argon for its own scintillation light has been estimated to be 1.10 m based on a very conservative approach.

  12. On the Electric Breakdown in Liquid Argon at Centimeter Scale

    CERN Document Server

    Auger, M; Ereditato, A; Goeldi, D; Janos, S; Kreslo, I; Luethi, M; von Rohr, C Rudolf; Strauss, T; Weber, M S

    2015-01-01

    We present a study on the dependence of electric breakdown discharge parameters on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

  13. Liquid Argon Calorimetry with LHC-Performance Specifications

    CERN Multimedia

    2002-01-01

    % RD-3 Liquid Argon Calorimetry with LHC-Performance Specifications \\\\ \\\\Good electromagnetic and hadronic calorimetry will play a central role in an LHC detector. Among the techniques used so far, or under development, the liquid argon sampling calorimetry offers high radiation resistence, good energy resolution (electromagnetic and hadronic), excellent calibration stability and response uniformity. Its rate capabilities, however, do not yet match the requirements for LHC. \\\\ \\\\The aim of this proposal is to improve the technique in such a way that high granularity, good hermiticity and adequate rate capabilities are obtained, without compromising the above mentioned properties. To reach this goal, we propose to use a novel structure, the $^{\\prime\\prime}$accordion$^{\\prime\\prime}$, coupled to fast preamplifiers working at liquid argon temperature. Converter and readout electrodes are no longer planar and perpendicular to particles, as usual, but instead they are wiggled around a plane containing particles. ...

  14. Laser propagation and energy absorption by an argon spark

    OpenAIRE

    Bindhu, C V; Harilal, S S; Tillack, M. S.; Najmabadi, F; Gaeris, A C

    2003-01-01

    The laser propagation and energy absorption of an argon spark induced by a laser at different pressures is investigated. 8 ns pulses from a frequency-doubled Q-switched Nd:YAG laser are used to create the spark. The pressure of the argon is varied from 1 atm to 10 Torr. Significant energy absorption by the plasma is observed at high pressures (>100 Torr) while there is negligible absorption when the pressure is lower than 50 Torr. The plasma kernel showed distinct behavior with respect to las...

  15. Modelling of a supersonic ICP argon-hydrogen expansion

    International Nuclear Information System (INIS)

    An expanding argon-hydrogen plasma is investigated by means of simulations. The model is a hydrodynamical model specific for plasma expansions, taking into account the conservation laws of mass, momentum and energy. The code includes the Rankine-Hugoniot relations to calculate shock jump conditions. Results are shown for the expansion from an inductively coupled plasma (ICP) with a separated Laval nozzle. The expansion discussed here is a 'weakly' under-expanding argon-hydrogen plasma. The results from the ICP expansion are verified with probe measurements

  16. Oxygen removal from tantalum and niobium in an argon atmosphere

    International Nuclear Information System (INIS)

    The rate of oxygen removal from tantalum and niobium has been determined as a function of argon pressure (0-760 Torr) at temperatures from 1900 to 24000C. The reduction of the reaction rate v depends only on the argon pressure and can be given by a factor α = v/v0. The following formulae are obtained for α: Ta: α = (1 + 0.15psub(Ar)sup(0.9))-1, Nb: α = (1 + 0.5psub(Ar)sup(0.9))-1.

  17. Photoionization in liquid argon doped with trimethylamine or triethylamine

    International Nuclear Information System (INIS)

    Ionization yields for alpha particles and 1 MeV electrons in liquid argon doped with trimethylamine and with triethylamine have been measured. In both liquids, a collected charge larger than Anderson's results is observed for alpha particles although that for electrons is similar to Anderson's value. By using a new equation for the collected charge, the photoionization quantum efficiencies for scintillation light in liquid argon are estimated to be 0.35+-0.05 for trimethylamine and greater than 0.23+-0.03 for triethylamine. (orig.)

  18. Superconductivity of compressed solid argon from first principles

    Science.gov (United States)

    Ishikawa, Takahiro; Asano, Masamichi; Suzuki, Naoshi; Shimizu, Katsuya

    2015-02-01

    We present first-principles calculations on the superconductivity of solid argon under high pressure. Solid argon is found to take the double hexagonal close-packed structure in pressure range from 420 to 690 GPa, where an insulator-to-metal transition occurs at around 590 GPa. The crystal structure transforms into the hexagonal close-packed structure at 690 GPa and into the face-centered cubic structure at 2300 GPa. The superconducting critical temperature is gradually increased with the successive phase transitions and reaches the maximum value of 12 K at 2600 GPa due to the enhancement of the Fermi surface nesting.

  19. Attosecond-correlated dynamics of two electrons in argon

    Indian Academy of Sciences (India)

    V Sharma; N Camus; B Fischer; M Kremer; A Rudenko; B Bergues; M Kuebel; N G Johnson; M F Kling; T Pfeifer; J Ullrich; R Moshammer

    2014-01-01

    In this work we explored strong field-induced decay of doubly excited transient Coulomb complex Ar** → Ar2++2. We measured the correlated two-electron emission as a function of carrier envelop phase (CEP) of 6 fs pulses in the non-sequential double ionization (NSDI) of argon. Classical model calculations suggest that the intermediate doubly excited Coulomb complex loses memory of its formation dynamics. We estimated the ionization time difference between the two electrons from NSDI of argon and it is 200 ± 100 as (N Camus et al, Phys. Rev. Lett. 108, 073003 (2012)).

  20. The ATLAS liquid argon electromagnetic calorimeter construction status

    CERN Document Server

    Jérémie, A

    2004-01-01

    The construction and assembly of the ATLAS liquid argon electromagnetic calorimeter was described. The calorimeter was built with accordion geometry composed of lead absorbers, liquid argon as ionizing medium and highly granular readout electrodes. The calorimeter was composed of the Barrel and the End-cap, both preceded by presampler sectors to ensure complete recovery of the energy resolution. The detection of cabling errors and testing of the whole calibration chain was done by sending a pulse through the calibration circuit with single readout. (Edited abstract) 3 Refs.

  1. The Erosion of Frozen Argon by Swift Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Graversen, O.; Hansen, Jens Leonhart; Sørensen, H.

    The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore unequivo......The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore...

  2. Measurement of Longitudinal Electron Diffusion in Liquid Argon

    CERN Document Server

    Li, Yichen; Thorn, Craig; Qian, Xin; Diwan, Milind; Joshi, Jyoti; Kettell, Steve; Morse, William; Rao, Triveni; Stewart, Jim; Tang, Wei; Viren, Brett

    2015-01-01

    We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data analysis are described. Our results, which are consistent with previous measurements in the region between 100 to 350 V/cm [1] , are systematically higher than the prediction of Atrazhev-Timoshkin[2], and represent the world's best measurement in the region between 350 to 2000 V/cm. The quantum efficiency of the gold photocathode, the drift velocity and longitudinal diffusion coefficients in gas argon are also presented.

  3. Neutron diffraction study of aluminum chloride imidazolium chloride molten salts

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, S. [Nisshin Steel Co. Ltd., Tokyo (Japan); Saboungi, M.L.; Suzuya, K. [Argonne National Lab., IL (United States); Koura, N. [Tokyo University of Science, Tokyo (Japan). Faculty of Science and Technology

    1994-02-01

    The structure of molten mixtures of (AlCl{sub 3}){sub x}(1-ethyl-3-methylimidazolium chloride){sub 1-x} was investigated by neutron diffraction techniques for x=0.46, 0.50, 0.60 and 0.67. Results derived from earlier ab initio molecular orbital (6-31G* basis set) computations for AlCl{sub 4}{sup {minus}}, Al{sub 2}Cl{sub 7}{sup {minus}}, and EMI{sup +} were used to calculate the diffraction patterns; the calculated contributions of each species are thus obtained and overall results are in good agreement with measurements.

  4. Uranium-liquid argon calorimetry: preliminary results from the DO tests

    International Nuclear Information System (INIS)

    The motivations for using uranium and liquid argon in sampling calorimetry are reviewed and the pros and cons of the technique are discussed. Preliminary results of the DO uranium-liquid argon test program are presented. 9 refs., 7 figs

  5. Synthesis of Zirconium Lower Chlorides

    International Nuclear Information System (INIS)

    This research is accurately related to the Halox concept of research reactor spent fuel element treatment.The aim of this project is to work the conditioning through selected chlorination of the element that make the spent fuel element. This research studied the physical chemistry conditions which produce formation of the lower zirconium chlorides through the reaction between metallic Zr and gaseous ZrCl4 in a silica reactor.This work focused special attention in the analysis and confrontation of the published results among the different authors in order to reveal coincidences and contradictions.Experimental section consisted in a set of synthesis with different reaction conditions and reactor design. After reaction were analyzed the products on Zr shavings and the deposit growth on wall reactor.The products were strongly dependent of reactor design. It was observed that as the distance between Zr and wall reactor increased greater was tendency to lower chlorides formation.In reactors with small distance the reaction follows other way without formation of lower chlorides.Analysis on deposit growth on reactor showed that may be formed to a mixture of SixZry intermetallics and zirconium oxides.Presence of oxygen in Zr and Zr-Si compounds on wall reactor reveals that there is an interaction between quartz and reactants.This interaction is in gaseous phase because contamination is observed in experiences where Zr was not in contact with reactor.Finally, it was made a global analysis of all experiences and a possible mechanism that interprets reaction ways is proposed

  6. Optical emission spectroscopy of argon and hydrogen-containing plasmas

    Science.gov (United States)

    Siepa, Sarah; Danko, Stephan; Tsankov, Tsanko V.; Mussenbrock, Thomas; Czarnetzki, Uwe

    2015-09-01

    Optical emission spectroscopy (OES) on neutral argon is applied to investigate argon, hydrogen and hydrogen-silane plasmas. The spectra are analyzed using an extensive collisional-radiative model (CRM), from which the electron density and the electron temperature (or mean energy) can be calculated. The CRM also yields insight into the importance of different excited species and kinetic processes. The OES measurements are performed on pure argon plasmas at intermediate pressure. Besides, hydrogen and hydrogen-silane plasmas are investigated using argon as a trace gas. Especially for the gas mixture discharges, CRMs for low and high pressure differ substantially. The commonly used line-ratio technique is found to lose its sensitivity for gas mixture discharges at higher pressure. A solution using absolutely calibrated line intensities is proposed. The effect of radiation trapping and the shape of the electron energy distribution function on the results are discussed in detail, as they have been found to significantly influence the results. This work was supported by the Ruhr University Research School PLUS, funded by Germany's Excellence Initiative [DFG GSC 98/3].

  7. High-frequency electrodeless lamps in argon-mercury mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Denisova, N [Institute of Theoretical and Applied Mechanics, Novosibirsk (Russian Federation); Revalde, G [Institute of Atomic Physics and Spectroscopy, University of Latvia, Raina blvd. 19, Riga (Latvia); Skudra, A [Institute of Atomic Physics and Spectroscopy, University of Latvia, Raina blvd. 19, Riga (Latvia); Zissis, G [CPAT, University Toulouse 3, 118 rte de Narbonne, 31062 Toulouse (France); Zorina, N [Institute of Atomic Physics and Spectroscopy, University of Latvia, Raina blvd. 19, Riga (Latvia)

    2005-09-07

    In this paper, numerical and experimental investigations of high-frequency (HF) electrodeless lamps in argon-mercury mixtures are performed. The intensities of the mercury spectral lines having wavelengths {lambda} = 404.66, 435.83, 546.07 nm (7{sup 3}S{sub 1}-6{sup 3}P{sub 0,1,2}) and the resonance line {lambda} = 253.7 nm (6{sup 3} P{sub 1}-6{sup 1}S{sub 0}) are measured at a wide range of mercury pressures, varying the HF generator current and argon filling pressure. A stationary self-consistent model of HF electrodeless discharge lamp is developed including kinetics of the excited mercury and argon atomic states. Based on the developed model, the radiation characteristics of the discharge plasma are calculated. Numerical simulation of the line intensities behaviour in dependence on the mercury pressure, HF generator current and argon filling pressure is performed. The model results are in qualitative agreement with the experimental data. The calculations of the relative intensities of the visible triplet lines 7{sup 3}S{sub 1}-6{sup 3}P{sub 0,1,2} are presented for the first time in this paper.

  8. Measurement of the argon plasma temperature by use of pyrometer

    International Nuclear Information System (INIS)

    The author describes in detail how to use pyrometer to measure the plasma temperature. The temperatures of shock-generated argon plasmas are given in the present work. Measured results of temperature-pressure curve are compared with calculated results using Saha-Debye-Huckel model, which are in good agreement

  9. LArGe. A liquid argon scintillation veto for GERDA

    International Nuclear Information System (INIS)

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in 76Ge, by operating naked germanium detectors submersed into 65 m3 of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m3 (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 103 have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10-2 cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural 42Ar abundance (in parallel to Gerda), and have indication for the 2νββ-decay in natural germanium. (orig.)

  10. Study of Liquid Argon Dopants for LHC Hadron Calorimetry

    CERN Multimedia

    2002-01-01

    Hadron calorimetry based on the Liquid Argon Ionisation Chamber technique is one of the choice techniques for LHC-experimentation. A systematic study of the effect of selected dopants on Liquid Argon (LAr) will be carried out with the aim to achieve an improvement on: \\item (i)~``Fast Liquid Argon'' search and study of dopants to increase the drift velocity. It has been already shown that CH&sub4. added at a fraction of one percent increases the drift velocity by a factor of two or more. \\item (ii)~``Compensated Liquid Argon'' search and study of dopants to increase the response to densely ionising particles, resulting in improved compensation, such as photosensitive dopants. \\end{enumerate}\\\\ \\\\ Monitoring of the parameters involved in understanding the response of a calorimeter is essential. In case of doped LAr, the charge yield, the non-saturated drift velocity and the electron lifetime in the liquid should be precisely and simultaneously monitored as they all vary with the level of dopant concentrati...

  11. Aging tests of ethylene contaminated argon/ethane

    International Nuclear Information System (INIS)

    We report on aging tests of argon/ethane gas with a minor (1800 ppM) component of ethylene. The measurements were first conducted with the addition of alcohol to test the suppression of aging by this additive, with exposure up to ∼1.5 C/cm. Tests have included: a proportional tube with ethanol, another with isopropyl alcohol, and for comparison a tube has also been run with ethanol and argon/ethane from CDF's old (ethylene-free) ethane supply. The aging test with ethanol showed no difference between the ethylene-free and the ethylene tube. Furthermore, raw aging rates of argon/ethane and argon/ethane/ethylene were measured by exposing tubes without the addition of alcohol to about 0.1 C/cm. Again, no significant difference was observed. In conclusion, we see no evidence that ethylene contamination up to 1800 ppM has any adverse effect on wire aging. However, this level of ethylene does seem to significantly suppress the gas gain

  12. The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning

    International Nuclear Information System (INIS)

    The ATLAS liquid argon (LAr) calorimeter system consists of an electromagnetic barrel calorimeter and two end caps with electromagnetic, hadronic and forward calorimeters. The liquid argon sampling technique, with an accordion geometry was chosen for the barrel electromagnetic calorimeter (EMB) and adapted to the end cap (EMEC). The hadronic end cap calorimeter (HEC) uses a copper-liquid argon sampling technique with flat plate geometry and is subdivided in depth in two wheels per end-cap. Finally, the forward calorimeter (FCAL) is composed of three modules employing cylindrical electrodes with thin liquid argon gaps.The construction of the full calorimeter system is complete since mid-2004. Production modules constructed in the home institutes were integrated into wheels at CERN in 2003-2004, and inserted into the three cryostats. They passed their first complete cold test before the lowering into the ATLAS cavern. Results of quality checks (e.g. electrical, mechanical, ...) performed on all the 190304 read-out channels after cool down will be reported. End 2004 the ATLAS barrel electromagnetic (EM) calorimeter was installed in the ATLAS cavern and since summer 2005 the front-end electronics are being connected and tested. Results of this first commissioning phase will be shown to demonstrate the high standards of quality control for our detectors

  13. Investigation of non-equilibrium argon and hydrogen plasmas

    International Nuclear Information System (INIS)

    Theoretical and experimental investigations are made into non-equilibrium argon and hydrogen partially-ionized plasmas characteristic of glow-discharge devices such as thyratrons and discharge tubes. For an argon plasma, the development and use of a collisional-radiative, steady-state, three-energy-level model is presented, and experimental measurements on pulsed argon plasmas are briefly mentioned. Two different theoretical argon plasma models are discussed; the first is numerically solved using a non-Maxwellian electron distribution function, while the second is solved analytically, including atom-atom inelastic collisions, assuming Maxwellian electron and atom distribution functions. For a hydrogen plasma, experimental measurements using fluorescence and laser-induced fluorescence have been made in a modified hydrogen thyratron over a wide current density range (from 100 to 8000 A/cm2) for the atomic hydrogen population densities n = 2,3,4. A pronounced rise in the atomic hydrogen excited state populations is observed after the end of the current pulse. A new method to measure the time-resolved electron density was developed and results are presented

  14. X ray diagnostics of the argon filled dense plasma focus

    International Nuclear Information System (INIS)

    An experimental investigation has been conducted to use a Dense Plasma Focus Machine as a prospected high intensity pulsed x ray source. The argon was chosen for the plasma discharge. An effort to reach the highest x ray intensity emission has been made. Although it has not yet been possible to operate with as high energy in argon as in hydrogen, the argon focus provides an intensified ''point source'' of x ray. Based on the diagnostic data and the characteristic difference between argon and hydrogen, a theoretical model of the shock wave was proposed. The x ray energy spectrum of the focus was determined by a crystal spectrometer. Analyzing this spectrum, one can obtain a combined radiation from a 3 keV thermal plasma and a 48 keV electron beam bombarding the center electrode. The polarization of the x ray was measured at a direction perpendicular to the DPF axis. The change of the polarization with time indicated that the plasma impinged radially and then followed by an axial flow. The correlation of the x ray signal with the voltage signal showed that the plasma resistance was rising after the density reached its maximum, and associated the increase of the resistivity as a result of ion-acoustic instability

  15. Scattering of Slow Metastable Argon Atoms by Dielectric Nanospheres

    Science.gov (United States)

    Baudon, J.; Hamamda, M.; Grucker, J.; Perales, F.; Dutier, G.; Ducloy, M.; Bocvarski, V.

    2009-11-01

    The elastic scattering at low energy of metastable argon atoms with internal angular momentum J = 0 and 2 by dielectric nanospheres is investigated. The differential cross sections are calculated for both isotropic and anisotropic interactions. A polarization effect is clearly evidenced. The possible use of a metastable atom beam as a probe of an ensemble of nanospheres deposited on a passive substrate is examined.

  16. LArGe. A liquid argon scintillation veto for GERDA

    Energy Technology Data Exchange (ETDEWEB)

    Heisel, Mark

    2011-04-13

    LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for possible applications in the GERDA experiment. GERDA searches for the neutrinoless double-beta decay in {sup 76}Ge, by operating naked germanium detectors submersed into 65 m{sup 3} of liquid argon. Similarly, LArGe runs Ge-detectors in 1 m{sup 3} (1.4 tons) of liquid argon, which in addition is instrumented with photomultipliers to detect argon scintillation light. The light is used in anti-coincidence with the germanium detectors, to effectively suppress background events that deposit energy in the liquid argon. This work adresses the design, construction, and commissioning of LArGe. The background suppression efficiency has been studied in combination with a pulse shape discrimination (PSD) technique for various sources, which represent characteristic backgrounds to GERDA. Suppression factors of a few times 10{sup 3} have been achieved. First background data of LArGe (without PSD) yield a background index of (0.12-4.6).10{sup -2} cts/(keV.kg.y) (90% c.l.), which is at the level of the Gerda phase I design goal. Furthermore, for the first time we measure the natural {sup 42}Ar abundance (in parallel to Gerda), and have indication for the 2{nu}{beta}{beta}-decay in natural germanium. (orig.)

  17. Design of capsules capable of argon-filling

    International Nuclear Information System (INIS)

    The possibility of the use of polycarbosilane capsules as fuel container in inertial confinement fusion experiments was analyzed in the paper. Primary study indicates that the polycarbosilane capsules can be filled with argon by means of diffusion and possess reasonable retention time for deuterium. (author)

  18. Laser-induced vibrational dynamics of ozone in solid argon

    DEFF Research Database (Denmark)

    Hansen, Flemming Yssing; Amstrup, B.; Henriksen, Niels Engholm

    We consider the vibrational dynamics, induced by an intense infrared laser pulse, in an ozone molecule with isotopic substitution, that is, (OOO)-O-16-O-16-O-18 and compare the dynamics in the gas phase and in solid ar on. not perturbed by argon on a time-scale of a few picoseconds and selective...

  19. Experimental and numerical study of high intensity argon cluster beams

    International Nuclear Information System (INIS)

    Experimental and numerical investigations of expansion of argon with homogeneous condensation in supersonic conical nozzle and in free jet behind it were carried out. Optimal parameters (stagnation pressure, nozzle-skimmer distance) for the formation of cluster beam with maximum intensity were determined. Two available models for nonequilibrium nucleation were tested. The numerical results are in satisfactory agreement with the measured data

  20. Thermal decomposition of yttrium(III) valerate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Tang, Xiao; Pallewatta, Pallewatta G A P; Watenphul, A.; Zimmermann, M. v.

    2014-01-01

    The thermal decomposition of yttrium(III) valerate (Y(C4H9CO2)3) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction, in-situ synchrotron diffraction and hot-stage microscopy as well as room temperature optical microscopy. Melting...

  1. Turbulence and transport in a magnetized argon plasma

    International Nuclear Information System (INIS)

    An experimental study on turbulence and transport in the highly ionized argon plasma of a hollow cathode discharge is described. In order to determine the plasma parameters three standard diagnostics have been used, whilst two diagnostics have been developed to study the plasma turbulence. (Auth.)

  2. Study of a microwave discharge in argon/helium mixtures

    International Nuclear Information System (INIS)

    A discharge created by a surface wave in Argon-Helium mixture is studied. First, the helium influence on plasma parameters has been studied (electron density, electric field, effective collision frequency, etc...), then, on excitation processes in the discharge. Relations between plasma lines, electron density and electric field have been established

  3. Thermophysical properties of multi-shock compressed dense argon.

    Science.gov (United States)

    Chen, Q F; Zheng, J; Gu, Y J; Chen, Y L; Cai, L C; Shen, Z J

    2014-02-21

    In contrast to the single shock compression state that can be obtained directly via experimental measurements, the multi-shock compression states, however, have to be calculated with the aid of theoretical models. In order to determine experimentally the multiple shock states, a diagnostic approach with the Doppler pins system (DPS) and the pyrometer was used to probe multiple shocks in dense argon plasmas. Plasma was generated by a shock reverberation technique. The shock was produced using the flyer plate impact accelerated up to ∼6.1 km/s by a two-stage light gas gun and introduced into the plenum argon gas sample, which was pre-compressed from the environmental pressure to about 20 MPa. The time-resolved optical radiation histories were determined using a multi-wavelength channel optical transience radiance pyrometer. Simultaneously, the particle velocity profiles of the LiF window was measured with multi-DPS. The states of multi-shock compression argon plasma were determined from the measured shock velocities combining the particle velocity profiles. We performed the experiments on dense argon plasmas to determine the principal Hugonoit up to 21 GPa, the re-shock pressure up to 73 GPa, and the maximum measure pressure of the fourth shock up to 158 GPa. The results are used to validate the existing self-consistent variational theory model in the partial ionization region and create new theoretical models. PMID:24559345

  4. Thermal decomposition of yttrium(III) hexanoate in argon

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Suarez Guevara, Maria Josefina; Attique, Fahmida;

    2015-01-01

    The thermal decomposition of yttrium(III) hexanoate (Y(C5H11CO2)3)·xH2O in argon was studied by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction at a laboratory Cu-tube source and in-situ experiments at a synchrotron radiation source as well as hot...

  5. The role of metastable atoms in argon-diluted silane radiofrequency plasmas

    OpenAIRE

    Sansonnens, L.; Howling, A.A.; Hollenstein, C.; Dorier, J. L.; Kroll, U.

    2008-01-01

    The evolution of the argon metastable states density has been studied by absorption spectroscopy in power-modulated plasmas of argon and a mixture of 4% silane in argon. A small concentration of silane suppresses the argon metastable states density by molecular quenching. This molecular quenching adds to the electronic collisional dissociation to increase the silane dissociation rate as compared with pure silane plasmas. Using time-resolved emission spectroscopy, the role of metastable states...

  6. Potassium-Argon ages on mesozoic tholeutic dike Swarm in Rio Grande do Norte, Brazil

    International Nuclear Information System (INIS)

    Potassium-argon ages are reported for samples from four localities which represent three laterally separated Mesozoic tholeitic dikes in Precambrian oF Rio Grande do Norte, Brazil. The ages for the dikes are between 167 Ma and 130 Ma. It is shown that most of the ages determined are minimum ages due to argon losses. The methodological approach to identify argon losses is described. Ecess argon cannot be of significant influence on the ages found. (author)

  7. Conversion of an atomic to a molecular argon ion and low pressure argon relaxation

    Science.gov (United States)

    M, N. Stankov; A, P. Jovanović; V, Lj Marković; S, N. Stamenković

    2016-01-01

    The dominant process in relaxation of DC glow discharge between two plane parallel electrodes in argon at pressure 200 Pa is analyzed by measuring the breakdown time delay and by analytical and numerical models. By using the approximate analytical model it is found that the relaxation in a range from 20 to 60 ms in afterglow is dominated by ions, produced by atomic-to-molecular conversion of Ar+ ions in the first several milliseconds after the cessation of the discharge. This conversion is confirmed by the presence of double-Gaussian distribution for the formative time delay, as well as conversion maxima in a set of memory curves measured in different conditions. Finally, the numerical one-dimensional (1D) model for determining the number densities of dominant particles in stationary DC glow discharge and two-dimensional (2D) model for the relaxation are used to confirm the previous assumptions and to determine the corresponding collision and transport coefficients of dominant species and processes. Project supported by the Ministry of Education, Science and Technological Development of the Republic of Serbia (Grant No. ON171025).

  8. Argon metastable dynamics and lifetimes in a direct current microdischarge

    Science.gov (United States)

    Stefanović, Ilija; Kuschel, Thomas; Schröter, Sandra; Böke, Marc

    2014-09-01

    In this paper we study the properties of a pulsed dc microdischarge with the continuous flow of argon. Argon metastable lifetimes are measured by tunable diode laser absorption spectroscopy (TDLAS) and are compared with calculated values which yield information about excitation and de-excitation processes. By increasing the gas flow-rate about 5 times from 10 to 50 sccm, the Arm lifetime increases from 1 to 5 μs due to the reduction of metastable quenching with gas impurities. Optical emission spectroscopy reveals nitrogen and water molecules as the main gas impurities. The estimated N2 density [N2] = 0.1% is too low to explain the measured metastable lifetimes. Water impurity was found to be the main de-excitation source of argon metastable atoms due to high quenching coefficients. The water impurity level of [H2O] = 0.15% to 1% is sufficient to bring calculated metastable lifetimes in line with experiments. The maximum value of water content in the discharge compared to the argon atoms is estimated to approximately 6%, due to the large surface to volume ratio of the microdischarge. The current pulse releases the water molecules from the electrode surface and they are either re-adsorbed in the time between 0.4 ms for [H2O] = 1% and 2.6 ms for [H2O] = 0.15% or pumped out of the discharge with the speed equal to the gas flow-rate. Depending on its partial pressure, the water impurity re-adsorption time is of the order of magnitude or less then the argon gas residence time.

  9. Observations of acoustic-wave-induced superluminescence in an argon plasma

    International Nuclear Information System (INIS)

    It is shown that in an argon discharge plasma it is possible to obtain overpopulation of certain electronic levels of atomic argon under the influence of acoustic waves. When the specified threshold is exceeded, then a superluminescence (in the form of light flashes) from the overpopulated electronic levels of atomic argon is observed

  10. 21 CFR 874.4490 - Argon laser for otology, rhinology, and laryngology.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Argon laser for otology, rhinology, and laryngology. 874.4490 Section 874.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Argon laser for otology, rhinology, and laryngology. (a) Identification. The argon laser device for...

  11. Cooper hydrometallurgy and extraction from chloride media

    International Nuclear Information System (INIS)

    The development of copper hydrometallurgy is presented and various processes proposed for copper recovery from sulphide concentrates are discussed. Leaching, extraction and stripping are considered, including reagents and processes. The extraction of copper from chloride solutions is discussed. Various extractants are presented and their use for copper transfer from chloride solutions to the organic phase and back to chloride and to sulphate solutions is discussed. (author) 4 refs

  12. Method of processing chloride waste

    International Nuclear Information System (INIS)

    In a method of applying molten salt electrolysis to chloride wastes discharged from a electrolytic refining step of a dry reprocessing step for spent fuels, and removed with transuranium elements of long half-decaying time, metals capable of alloying with alkali and alkaline earth metals under melting by electrolysis are used as a cathode material, and an electrolytic temperature is made higher than the melting point of salts in a molten salt electrolysis bath, to recover Li, Ca and Na as alloys with the cathode material in a first electrolysis step. Then, the electrolytic temperature is made higher than the melting point of the chloride salts remained in the bath after the electrolysis step described above by using the cathode material, to recover Ba, Rb, Sr and Cs of nuclear fission products also as alloys with the cathode material in a second electrolysis step. Accordingly, the amount of wastes formed can be reduced, and the wastes contain no heat generating nuclear fission elements. (T.M.)

  13. Green process to recover magnesium chloride from residue solution of potassium chloride production plant

    Institute of Scientific and Technical Information of China (English)

    Lin WANG; Yunliang HE; Yanfei WANG; Ying BAO; Jingkang WANG

    2008-01-01

    The green process to recover magnesium chlor-ide from the residue solution of a potassium chloride pro-duction plant, which comes from the leach solution of a potash mine in Laos, is designed and optimized. The res-idue solution contains magnesium chloride above 25 wt-%, potassium chloride and sodium chloride together below 5 wt-% and a few other ions such as Br-, SO2-4and Ca2+. The recovery process contains two steps: the previous impurity removal operation and the two-stage evapora-tion-cooling crystallization procedure to produce magnes-ium chloride. The crystallized impurity carnallite obtained from the first step is recycled to the potassium chloride plant to recover the potassium salt. The developed process is a zero discharge one and thus fulfills the requirements for green chemical industrial production. The produced magnesium chloride is up to industrial criteria.

  14. Factors influencing chloride deposition in a coastal hilly area and application to chloride deposition mapping

    OpenAIRE

    H. Guan; Love, A. J.; C. T. Simmons; Makhnin, O.; A. S. Kayaalp

    2010-01-01

    Chloride is commonly used as an environmental tracer for studying water flow and solute transport in the environment. It is especially useful for estimating groundwater recharge based on the commonly used chloride mass balance (CMB) method. Strong spatial variability in chloride deposition in coastal areas is one difficulty encountered in appropriately applying the method. A high-resolution bulk chloride deposition map in the coastal region is thus needed. The aim of this study is to construc...

  15. Factors influencing chloride deposition in a coastal hilly area and application to chloride deposition mapping

    OpenAIRE

    H. Guan; Love, A. J.; C. T. Simmons; Makhnin, O.; A. S. Kayaalp

    2010-01-01

    Chloride is commonly used as an environmental tracer for studying water flow and solute transport in the environment. It is especially useful for estimating groundwater recharge based on the commonly used chloride mass balance (CMB) method. Strong spatial variability in chloride deposition in coastal areas is one difficulty encountered in appropriately applying the method. A high-resolution bulk chloride deposition map in the coastal region is thus needed. The aim of this st...

  16. Method to determine argon metastable number density and plasma electron temperature from spectral emission originating from four 4p argon levels

    CERN Document Server

    Mariotti, Davide; Sasaki, Takeshi; Koshizaki, Naoto; 10.1063/1.2390631

    2010-01-01

    A simple model and method is proposed here to determine argon metastable number densities and electron temperature with the assumption of a Maxwell-Boltzmann electron energy distribution. This method is based on the availability of experimental relative emission intensities of only four argon lines that originate from any of the 4p argon levels. The proposed model has a relatively wide range of validity for laboratory plasmas that contain argon gas and can be a valuable tool for the emerging field of atmospheric microplasmas, for which diagnostics is still limited.

  17. EFFECTS OF ARGON ON THE PROPERTIES OF RF SPUTTERED AMORPHOUS SILICON

    OpenAIRE

    Shao-Qi, Peng; Qai, Yu; Xian, Zhang; Jing, Ye

    1981-01-01

    The Effects of argon on the properties of rf sputtered amorphous silicon film have been investigated. As the sputtering argon pressure is increased from 2 to 20 mTorr, the content of argon in the amorphous silicon film increases apparently (Argon/Silicon : from 10-2 to 5 x 10-2). The other properties measured as a function of argon pressure PAr show that as the PAr is increased, the photoconductivity, resistivity (300K), conductivity activation energy and optical gap increase also, while the ...

  18. First Commissioning of a Cryogenic Distillation Column for Low Radioactivity Underground Argon

    CERN Document Server

    Back, Henning O; Alton, Andrew; Condon, Christopher; de Haas, Ernst; Galbiati, Cristiano; Goretti, Augusto; Hohmann, Tristan; Ianni, Andrea; Kendziora, Cary; Loer, Ben; Montanari, David; Mosteiro, Pablo; Pordes, Stephen

    2012-01-01

    We report on the performance and commissioning of a cryogenic distillation column for low radioactivity underground argon at Fermi National Accelerator Laboratory. The distillation column is designed to accept a mixture of argon, helium, and nitrogen and return pure argon with a nitrogen contamination less than 10 ppm. In the first commissioning, we were able to run the distillation column in a continuous mode and produce argon that is 99.9% pure. After running in a batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The efficiency of collecting the argon from the gas mixture was between 70% and 81%, at an argon production rate of 0.84-0.98 kg/day.

  19. Electrochemical Chloride extraction using external electrodes?

    DEFF Research Database (Denmark)

    Ottosen, Lisbeth M.; Pedersen, Anne Juul

    cathode. However, some unwanted side effects can occur, including alkali-silica reaction and in some cases hydrogen embrittlement. It is also suggested also to use electrochemical chloride extraction in a preventive way in constructions where chloride induced corrosion is likely to be a problem after a...

  20. Chloride binding site of neurotransmitter sodium symporters

    DEFF Research Database (Denmark)

    Kantcheva, Adriana Krassimirova; Quick, Matthias; Shi, Lei;

    2013-01-01

    Neurotransmitter:sodium symporters (NSSs) play a critical role in signaling by reuptake of neurotransmitters. Eukaryotic NSSs are chloride-dependent, whereas prokaryotic NSS homologs like LeuT are chloride-independent but contain an acidic residue (Glu290 in LeuT) at a site where eukaryotic NSSs...

  1. Chloride ingress in cement paste and mortar

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede; Hansen, Per Freiesleben; Coats, Alison M.; Glasser, Fred P.

    1999-01-01

    In this paper chloride ingress in cement paste and mortar is followed by electron probe microanalysis. The influence of several paste and exposure parameters on chloride ingress are examined (e.g., water-cement ratio, silica fume addition, exposure time, and temperature), The measurements are...

  2. Chloride ingress in cement paste and mortar

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede; Hansen, Per Freiesleben; Coats, Alison M.;

    1999-01-01

    modelled on Fick's law modified by a term for chloride binding. Inclusion of chloride binding significantly improves the profile shape of the modelled ingress profiles. The presence of fine aggregate and formation of interfacial transition zones at paste-aggregate boundaries does not significantly affect...

  3. Reliability-Based Planning of Chloride Measurements

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Engelund, S.

    1996-01-01

    on measurements of the chloride content obtained from the given structure. In the present paper optimal planning of measurements of the chloride content in reinforced concrete structures is considered. It is shown how optimal experimental plans can be obtained using FORM-analysis. Bayesian statistics...

  4. Properties of silver chloride track detectors

    International Nuclear Information System (INIS)

    The experiments on preparation of silver chloride track detectors and their properties are described. The results of X-ray structural analysis and data on sensitivity to charged particles and actinic light of silver chloride crystals, doped with several elements, are presented. (orig.)

  5. [Experience with argon laser in urological diseases (author's transl)].

    Science.gov (United States)

    Rothauge, C F; Nöske, H D; Kraushaar, J

    1981-09-01

    The application of the Argon laser in urology has proved to be effective in resecting recurrent, exophytic urothelial tumors of the bladder up to the size of a raspberry. In cases of wide spread bladder tumors we only perform a radiation of the resected area as local recurrence prophylaxis following transurethral resection. The urethroscopic Argon laser irradiation makes laser urethrotomy and evaporisation of urethral strictures possible. Furthermore, a curative and conservative treatment of urethral tumors is possible in combination with chemotherapy. The same applies for the penis carcinoma. Urethral ruptures are also successfully treated by urethroscopic laser recanalization. A determination of the ureteral submucosal course, which may allow a prognosis about the probable maturation, is possible in cases of cystoureteral reflux with the help of laser diaphanoscopy. PMID:7197839

  6. Development of cryogenic installations for large liquid argon neutrino detectors

    CERN Document Server

    Adamowski, M; Geynisman, M; Hentschel, S; Montanari, D; Nessi, M; Norris, B

    2015-01-01

    A proposal for a very large liquid argon (68,000 kg) based neutrino detector is being studied. To validate the design principles and the detector technology, and to gain experience in the development of the cryostats and the cryogenic systems needed for such large experiments, several smaller scale installations will be developed and implemented, at Fermilab and CERN. The cryogenic systems for these installations will be developed, constructed, installed and commissioned by an international engineering team. These installations shall bring the required cooling power under specific conditions to the experiments for the initial cool-down and the long term operation, and shall also guarantee the correct distribution of the cooling power within the cryostats to ensure a homogeneous temperature distribution within the cryostat itself. The cryogenic systems shall also include gaseous and liquid phase argon purification devices to be used to reach and maintain the very stringent purity requirements needed for these...

  7. Measurement of longitudinal electron diffusion in liquid argon

    Science.gov (United States)

    Li, Yichen; Tsang, Thomas; Thorn, Craig; Qian, Xin; Diwan, Milind; Joshi, Jyoti; Kettell, Steve; Morse, William; Rao, Triveni; Stewart, James; Tang, Wei; Viren, Brett

    2016-04-01

    We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data analysis are described. In the region between 100 and 350 V/cm, our results show a discrepancy with the previous measurement [1]. In the region between 350 and 2000 V/cm, our results represent the world's best measurement. Over the entire measured electric field range, our results are systematically higher than the calculation of Atrazhev-Timoshkin [2]. The quantum efficiency of the gold photocathode, the drift velocity and longitudinal diffusion coefficients in gas argon are also presented.

  8. Evaporation and condensation at a liquid surface. I. Argon

    Science.gov (United States)

    Yasuoka, Kenji; Matsumoto, Mitsuhiro; Kataoka, Yosuke

    1994-11-01

    Molecular dynamics computer simulations were carried out to investigate the dynamics of evaporation and condensation for argon at the temperature of 80 and 100 K. From the decrease of the survival probability of vapor molecules, the ratio of self reflection to collision is estimated to be 12%-15%, only weakly dependent on the temperature. This suggests that argon vapor molecules are in the condition of almost complete capture, and the condensation is considered to be a barrierless process. The total ratio of reflection which is evaluated with the flux correlation of condensation and evaporation is 20% at both temperature. The difference between these two ratios of reflection is ascribed to a phenomenon that vapor molecules colliding with the surface drive out other liquid molecules. This molecule exchange at the surface is as important as the self-reflection, and the conventional picture of condensation as a unimolecular chemical reaction is not appropriate.

  9. Trimming a Metallic Biliary Stent Using an Argon Plasma Coagulator

    International Nuclear Information System (INIS)

    Background. Distal migration is one of the common complications after insertion of a covered metallic stent. Stent repositioning or removal is not always possible in every patient. Therefore, trimming using an argon plasma coagulator (APC) may be a good alternative method to solve this problem. Methods. Metallic stent trimming by APC was performed in 2 patients with biliary Wallstent migration and in another patient with esophageal Ultraflex stent migration. The power setting was 60-100 watts with an argon flow of 0.8 l/min. Observations. The procedure was successfully performed and all distal parts of the stents were removed. No significant collateral damage to the nearby mucosa was observed. Conclusions. In a patient with a distally migrated metallic stent, trimming of the stent is possible by means of an APC. This new method may be applicable to other sites of metallic stent migration

  10. Narrow spectral width laser diode for metastable argon atoms pumping

    Science.gov (United States)

    Gao, Jun; Li, Bin; Wang, Xinbing; Zuo, Duluo

    2016-03-01

    Diode laser pump source with narrow emitting spectrum for optically pumped metastable rare gas laser (OPRGL) of argon was achieved by employing a complex external cavity coupled with volume Bragg grating (VBG). A commercially available c-mount laser diode with rated power of 6 W was used and studied in both the free running mode and VBG external cavity. The maximum output power of 3.9 W with FWHM less than 25 pm and peak wavelength locked around 811.53 nm was obtained from the VBG external cavity laser diode. Precise control of VBG temperature enabled fine tuning of the emission wavelength over a range of 450 pm. Future researches on OPRGL of argon will benefit from it.

  11. Scintillation time dependence and pulse shape discrimination in liquid argon

    International Nuclear Information System (INIS)

    Using a single-phase liquid argon detector with a signal yield of 4.85 photoelectrons per keV of electronic-equivalent recoil energy (keVee), we measure the scintillation time dependence of both electronic and nuclear recoils in liquid argon down to 5 keVee. We develop two methods of pulse shape discrimination to distinguish between electronic and nuclear recoils. Using one of these methods, we measure a background- and statistics-limited level of electronic recoil contamination to be 7.6x10-7 between 52 and 110 keV of nuclear recoil energy (keVr) for a nuclear recoil acceptance of 50% with no nuclear recoil-like events above 62 keVr. Finally, we develop a maximum likelihood method of pulse shape discrimination based on the measured scintillation time dependence

  12. Demonstration of a Lightguide Detector for Liquid Argon TPCs

    CERN Document Server

    Bugel, L; Ignarra, C; Jones, B J P; Katori, T; Smidt, T; Tanaka, H -K

    2011-01-01

    We report demonstration of light detection in liquid argon using an acrylic lightguide detector system. This opens the opportunity for development of an inexpensive, large-area light collection system for large liquid argon time projection chambers. The guides are constructed of acrylic, with TPB embedded in a surface coating with a matching index of refraction. We study the response to early scintillation light produced by a 5.3 MeV alpha. We measure coating responses from 7 to 8 PE on average, compared to an ideal expectation of 10 PE on average. We estimate the attenuation length of light along the lightguide bar to be greater than 0.5 m. The coating response and the attenuation length can be improved; we show, however, that these results are already sufficient for triggering in a large detector.

  13. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  14. The Erosion of Frozen Argon by Swift Helium Ions

    DEFF Research Database (Denmark)

    Besenbacher, F.; Bøttiger, Jørgen; Graversen, O.;

    1981-01-01

    The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore unequivo......The temperature, energy, and thickness dependence of the erosion rates of frozen argon films when irradiated with 0.1–3 MeV helium ions have been measured. The erosion yields Y are much too high to be explained by the concentional collisional cascade-sputtering theory and are furthermore...... unequivocally associated with electronic processes generated by the bombarding particle. In the present energy region, it is found that Y scales approximately as the electronic stopping power squared, depends on the charge state of the incoming helium ions, and perhaps more important, is independent of the...

  15. Readiness of the ATLAS Liquid Argon Calorimeter for LHC Collisions

    CERN Document Server

    Aad, G; Abdallah, J; Abdelalim, A A; Abdesselam, A; Abdinov, O; Abi, B; Abolins, M; Abramowicz, H; Abreu, H; Acharya, B S; Adams, D L; Addy, T N; Adelman, J; Adorisio, C; Adragna, P; Adye, T; Aefsky, S; Aguilar-Saavedra, J A; Aharrouche, M; Ahlen, S P; Ahles, F; Ahmad, A; Ahmed, H; Ahsan, M; Aielli, G; Akdogan, T; Åkesson, T P A; Akimoto, G; Akimov, A V; Aktas, A; Alam, M S; Alam, M A; Albert, J; Albrand, S; Aleksa, M; Aleksandrov, I N; Alessandria, F; Alexa, C; Alexander, G; Alexandre, G; Alexopoulos, T; Alhroob, M; Aliev, M; Alimonti, G; Alison, J; Aliyev, M; Allport, P P; Allwood-Spiers, S E; Almond, J; Aloisio, A; Alon, R; Alonso, A; Alviggi, M G; Amako, K; Amelung, C; Ammosov, V V; Amorim, A; Amorós, G; Amram, N; Anastopoulos, C; Andeen, T; Anders, C F; Anderson, K J; Andreazza, A; Andrei, V; Anduaga, X S; Angerami, A; Anghinolfi, F; Anjos, N; Antonaki, A; Antonelli, M; Antonelli, S; Antunovic, B; Anulli, F; Aoun, S; Arabidze, G; Aracena, I; Arai, Y; Arce, A T H; Archambault, J P; Arfaoui, S; Arguin, J-F; Argyropoulos, T; Arik, E; Arik, M; Armbruster, A J; Arnaez, O; Arnault, C; Artamonov, A; Arutinov, D; Asai, M; Asai, S; Asfandiyarov, R; Ask, S; Åsman, B; Asner, D; Asquith, L; Assamagan, K; Astbury, A; Astvatsatourov, A; Atoian, G; Auerbach, B; Auge, E; Augsten, K; Aurousseau, M; Austin, N; Avolio, G; Avramidou, R; Axen, D; Ay, C; Azuelos, G; Azuma, Y; Baak, M A; Baccaglioni, G; Bacci, C; Bach, A; Bachacou, H; Bachas, K; Backes, M; Badescu, E; Bagnaia, P; Bai, Y; Bailey, D C; Bain, T; Baines, J T; Baker, O K; Baker, M D; Baltasar Dos Santos Pedrosa, F; Banas, E; Banerjee, P; Banerjee, S; Banfi, D; Bangert, A; Bansal, V; Baranov, S P; Baranov, S; Barashkou, A; Barber, T; Barberio, E L; Barberis, D; Barbero, M; Bardin, D Y; Barillari, T; Barisonzi, M; Barklow, T; Barlow, N; Barnett, B M; Barnett, R M; Baron, S; Baroncelli, A; Barr, A J; Barreiro, F; BarreiroGuimarães da Costa, J; Barrillon, P; Barros, N; Bartoldus, R; Bartsch, D; Bastos, J; Bates, R L; Bathe, S; Batkova, L; Batley, J R; Battaglia, A; Battistin, M; Bauer, F; Bawa, H S; Bazalova, M; Beare, B; Beau, T; Beauchemin, P H; Beccherle, R; Becerici, N; Bechtle, P; Beck, G A; Beck, H P; Beckingham, M; Becks, K H; Bedajanek, I; Beddall, A J; Beddall, A; Bednár, P; Bednyakov, V A; Bee, C; Begel, M; Behar Harpaz, S; Behera, P K; Beimforde, M; Belanger-Champagne, C; Bell, P J; Bell, W H; Bella, G; Bellagamba, L; Bellina, F; Bellomo, M; Belloni, A; Belotskiy, K; Beltramello, O; Ben Ami, S; Benary, O; Benchekroun, D; Bendel, M; Benedict, B H; Benekos, N; Benhammou, Y; Benincasa, G P; Benjamin, D P; Benoit, M; Bensinger, J R; Benslama, K; Bentvelsen, S; Beretta, M; Berge, D; Bergeaas Kuutmann, E; Berger, N; Berghaus, F; Berglund, E; Beringer, J; Bernardet, K; Bernat, P; Bernhard, R; Bernius, C; Berry, T; Bertin, A; Besson, N; Bethke, S; Bianchi, R M; Bianco, M; Biebel, O; Biesiada, J; Biglietti, M; Bilokon, H; Bindi, M; Binet, S; Bingul, A; Bini, C; Biscarat, C; Bitenc, U; Black, K M; Blair, R E; Blanchard, J-B; Blanchot, G; Blocker, C; Blocki, J; Blondel, A; Blum, W; Blumenschein, U; Bobbink, G J; Bocci, A; Boehler, M; Boek, J; Boelaert, N; Böser, S; Bogaerts, J A; Bogouch, A; Bohm, C; Bohm, J; Boisvert, V; Bold, T; Boldea, V; Boldyrev, A; Bondarenko, V G; Bondioli, M; Boonekamp, M; Booth, J R A; Bordoni, S; Borer, C; Borisov, A; Borissov, G; Borjanovic, I; Borroni, S; Bos, K; Boscherini, D; Bosman, M; Bosteels, M; Boterenbrood, H; Bouchami, J; Boudreau, J; Bouhova-Thacker, E V; Boulahouache, C; Bourdarios, C; Boyd, J; Boyko, I R; Bozovic-Jelisavcic, I; Bracinik, J; Braem, A; Branchini, P; Brandenburg, G W; Brandt, A; Brandt, G; Brandt, O; Bratzler, U; Brau, B; Brau, J E; Braun, H M; Brelier, B; Bremer, J; Brenner, R; Bressler, S; Breton, D; Brett, N D; Britton, D; Brochu, F M; Brock, I; Brock, R; Brodbeck, T J; Brodet, E; Broggi, F; Bromberg, C; Brooijmans, G; Brooks, W K; Brown, G; Brubaker, E; Bruckman de Renstrom, P A; Bruncko, D; Bruneliere, R; Brunet, S; Bruni, A; Bruni, G; Bruschi, M; Buanes, T; Bucci, F; Buchanan, J; Buchholz, P; Buckley, A G; Budagov, I A; Budick, B; Büscher, V; Bugge, L; Bulekov, O; Bunse, M; Buran, T; Burckhart, H; Burdin, S; Burgess, T; Burke, S; Busato, E; Bussey, P; Buszello, C P; Butin, F; Butler, B; Butler, J M; Buttar, C M; Butterworth, J M; Byatt, T; Caballero, J; Cabrera Urbán, S; Caforio, D; Cakir, O; Calafiura, P; Calderini, G; Calfayan, P; Calkins, R; Caloba, L P; Caloi, R; Calvet, D; Camarri, P; Cambiaghi, M; Cameron, D; Campabadal-Segura, F; Campana, S; Campanelli, M; Canale, V; Canelli, F; Canepa, A; Cantero, J; Capasso, L; Capeans-Garrido, M D M; Caprini, I; Caprini, M; Capua, M; Caputo, R; Caracinha, D; Caramarcu, C; Cardarelli, R; Carli, T; Carlino, G; Carminati, L; Caron, B; Caron, S; Carrillo Montoya, G D; Carron Montero, S; Carter, A A; Carter, J R

    2010-01-01

    The ATLAS liquid argon calorimeter has been operating continuously since August 2006. At this time, only part of the calorimeter was readout, but since the beginning of 2008, all calorimeter cells have been connected to the ATLAS readout system in preparation for LHC collisions. This paper gives an overview of the liquid argon calorimeter performance measured in situ with random triggers, calibration data, cosmic muons, and LHC beam splash events. Results on the detector operation, timing performance, electronics noise, and gain stability are presented. High energy deposits from radiative cosmic muons and beam splash events allow to check the intrinsic constant term of the energy resolution. The uniformity of the electromagnetic barrel calorimeter response along eta (averaged over phi) is measured at the percent level using minimum ionizing cosmic muons. Finally, studies of electromagnetic showers from radiative muons have been used to cross-check the Monte Carlo simulation. The performance results obtained u...

  16. Diffusion behavior of chloride ions in concrete

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, T.; Gjoerv, O.E. [Norwegian Univ. of Science and Technology, Trondheim (Norway). Div. of Building Materials

    1996-06-01

    In the present paper, an analysis of the diffusion behavior of chloride ions in concrete is presented. In concentrated electrolytic aqueous solutions such as seawater or that typically used in laboratory experiments, the effect of ionic interaction may significantly reduce the chemical potential and thus the driving force of the diffusing species. Because of different drift velocities of the cations and chloride ions in the solution, the lagging motion of the cations will also retard the drift velocity of the chlorides. In addition, both the electrical double layer forming on the solid surface and the chemical binding may significantly interfere with the transport of the chloride ions. As a result, the diffusion behavior of the chloride ions in concrete is a more complex and complicated transport process than what can be described by Fick`s law of diffusion.

  17. Simple chloride sensors for continuous groundwater monitoring

    DEFF Research Database (Denmark)

    Thorn, Paul; Mortensen, John

    2012-01-01

    The development of chloride sensors which can be used for continuous, on-line monitoring of groundwater could be very valuable in the management of our coastal water resources. However, sensor stability, drift, and durability all need to be addressed in order for the sensors to be used in continu......The development of chloride sensors which can be used for continuous, on-line monitoring of groundwater could be very valuable in the management of our coastal water resources. However, sensor stability, drift, and durability all need to be addressed in order for the sensors to be used...... sensor remained responsive even at low chloride concentrations, where the conductivity electrode was no longer responding to changing chloride levels. With the results, it is believed that the simple chloride sensor could be used for continuous monitoring of groundwater quality....

  18. Electron Neutrino Classification in Liquid Argon Time Projection Chamber Detector

    OpenAIRE

    Płoński, Piotr; Stefan, Dorota; Sulej, Robert; Zaremba, Krzysztof

    2015-01-01

    Neutrinos are one of the least known elementary particles. The detection of neutrinos is an extremely difficult task since they are affected only by weak sub-atomic force or gravity. Therefore large detectors are constructed to reveal neutrino's properties. Among them the Liquid Argon Time Projection Chamber (LAr-TPC) detectors provide excellent imaging and particle identification ability for studying neutrinos. The computerized methods for automatic reconstruction and identification of parti...

  19. Unified set of atomic transition probabilities for neutral argon

    OpenAIRE

    Wiese, W.; Brault, J.; Danzmann, K.; Helbig, V.; de Kock, M

    1989-01-01

    The atomic transition probabilities and radiative lifetimes of neutral argon have been the subject of numerous experiments and calculations, but the results exhibit many discrepancies and inconsistencies. We present a unified set of atomic transition probabilities, which is consistent with essentially all recent results, albeit sometimes only after critical reanalysis. The data consistency and scale confirmation has been achieved in two ways. (i) We have carried out some lifetime–branching-ra...

  20. Operational performance of a large liquid argon photon calorimeter

    International Nuclear Information System (INIS)

    We describe the performance of a large (0.9x1.4 m2) liquid argon photon calorimeter in high energy experiments at Fermilab. Resolutions for π0 and electron showers, obtained under data-taking conditions, are compared with electron-beam calibration results. Exceptional spatial and time resolutions have been achieved for isolated showers (sigmasub(x,y)0 data up to 180 GeV are presented. (orig.)

  1. Changes in colour contrast sensitivity associated with operating argon lasers.

    OpenAIRE

    Gündüz, K; Arden, G B

    1989-01-01

    A new test of colour vision using computer graphics has been used to obtain quantitative estimates of colour contrast sensitivity in ophthalmologists before and after they have treated patients by argon laser retinal photocoagulation. The colour vision of all subjects is normal when tested with the 100-hue test and HRR (Hardy, Rittler, Rand) plates, but colour contrast sensitivity measured along a tritan colour confusion line is selectively impaired after a treatment session. No such change o...

  2. Influence of argon pollution on the weld surface morphology

    OpenAIRE

    Krolczyk, G.M.; Nieslony, P.; Krolczyk, J.B.; I. Samardzic; Legutko, S.; S. Hloch; Barrans, Simon; Maruda, R.W.

    2015-01-01

    In this paper the surfaces of butt welded joints in steel tubes were analyzed using an optical 3D measurement system to determine the morphology and topographic parameters. It was established that pollution of the argon shield gas with oxygen did not influence the width of the heat-affected zone. However, the composition of the shield gas significantly influenced the surface asymmetry, Ssk, and its inclination Sku. The measurement of these parameters enabled the selection of a ...

  3. Experimental Investigation of Low Pressure Audio Frequency Discharge in Argon

    International Nuclear Information System (INIS)

    Experimental data obtained on audio frequency (100–10000 Hz) discharge in argon at four pressures 50, 60, 70, and 80 mTorr are presented. The data show significant changes of the discharge current waveform with frequency. These changes seem to be associated with the glow discharge profile and colour. An empirical model based on the assumption of a frequency-dependent breakdown voltage is used to describe the experimental data

  4. STATUS OF THE ATLAS LIQUID ARGON CALORIMETER AND ITS PERFORMANCE

    CERN Document Server

    Berillari, T; The ATLAS collaboration

    2011-01-01

    The liquid argon (LAr) calorimeters are used in ATLAS for all electromagnetic and for hadron calorimetry. The LAr calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic, hadronic and forward calorimeters. The latest status of the detector as well as problems and solutions addressed during the last years will be presented. Aspects of operation of a large detector over a long time period will be summarized and selected topics showing the performance of the detector will be shown.

  5. Thermal decomposition of lanthanum(III) butyrate in argon atmosphere

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Yue, Zhao; Xiao, Tang;

    2013-01-01

    The thermal decomposition of La(C3H7CO2)3·xH2O (x≈0.82) was studied in argon during heating at 5K/min. After the loss of bound H2O, the anhydrous butyrate presents at 135°C a phase transition to a mesophase, which turns to an isotropic liquid at 180°C. The decomposition of the anhydrous butyrate ...

  6. Argon laser photocoagulation of cyclodialysis clefts after cataract surgery

    International Nuclear Information System (INIS)

    Three patients with cyclodialysis clefts, hypotony and hypotonic retinopathy subsequent to cataract surgery were treated with argon laser photocoagulation. The hypotony was reversed in each patient and their visual acuity was normalized. Laser photocoagulation is a noninvasive treatment that can be repeated easily and safely. The complications of the treatment are minor. A hypertensive episode commonly occurs in the early postoperative period. (au) 8 refs

  7. Spectroscopy of Argon Excited in an Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Trabert, E

    2005-04-18

    Argon is one of the gases best investigated and most widely used in plasma discharge devices for a multitude of applications that range from wavelength reference standards to controlled fusion experiments. Reviewing atomic physics and spectroscopic problems in various ionization stages of Ar, the past use and future options of employing an electron beam ion trap (EBIT) for better and more complete Ar data in the x-ray, EUV and visible spectral ranges are discussed.

  8. Spectroscopic Investigations of Air Entrainment into an Argon Plasma Jet

    Czech Academy of Sciences Publication Activity Database

    Hlína, Jan; Něnička, Václav; Šlechta, Jiří; Krejčí, Luděk; Dolínek, Vladimír; Sopuch, Pavel

    Vol. 3. Orléans : GREMI, CNRS/University of Orléans, 2001 - (Bouchoule, A.; Pouvesle, J.), s. 1107-1110 [INTERNATIONAL SYMPOSIUM ON PLASMA CHEMISTRY /15./. Orléans (FR), 09.07.2001-13.07.2001] R&D Projects: GA AV ČR IAA1057001; GA ČR GA202/99/0389 Keywords : nitrogen molecular bands * dependence of nitrogen radiations on the argon flow rate Subject RIV: BL - Plasma and Gas Discharge Physics

  9. Two dimensional condensation of argon adsorbed on lamellar halides

    International Nuclear Information System (INIS)

    Lamellar halides such as NiCl2, FeCl2, NiBr2, MnBr2, MgBr2, CdBr2, CoI2, FeI2, MnI2, CaI2 and PbI2 were sublimed in a rapid stream of dry nitrogen. The adsorption of argon on such materials shows stepped isotherms which reveal two dimensional condensations. From sets of isotherms the Helmholtz free energy, the internal energy and the entropy of the successive layers are determined. From the entropy of the first layer the role of the potential relief of the adsorbent surface on the structure of the adsorbed layer may be determined while the Helmholtz free energy reveals how the ionic character of the adsorbent governs the attractive force of adsorption. The study of the second third and fourth layers shows that their growth follows quite a different behaviour depending on whether the Van der Waals diameter of argon is greater or smaller than the distance between adjacent anions on the crystal surface. A proposition is made to account for the difference in the critical temperatures of the first and second dense layers in terms of the vibrationnal state of their respective substrate. The occurence for the maximum critical temperature observed of corresponding to a triangular layer 3% more expanded than the (111) plane of solid argon is discussed

  10. A liquid argon scintillation veto for the Gerda experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Bare germanium detectors are operated in a cryostat with 65 m{sup 3} of liquid argon (LAr). To reach the aspired background index of ≤10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). A light instrumentation of LAr installed in the LArGe test facility has demonstrated that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. Based on these results, Gerda pursues several options for the light instrumentation, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Q{sub ββ} at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. The design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed, together with their expected performance from Monte Carlo simulations. In addition, the progress of development is reported, along with the design criteria for light instrumentation in Gerda.

  11. A liquid argon scintillation veto for the Gerda experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Bare germanium detectors are operated in a cryostat with 65 m3 of liquid argon (LAr). To reach the aspired background index of ≤10-3 cts/(keV.kg.yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). A light instrumentation of LAr installed in the LArGe test facility has demonstrated that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. Based on these results, Gerda pursues several options for the light instrumentation, which have to be compatible with the stringent radiopurity requirements of the experiment and should provide a significant suppression of the background in the region of interest around Qββ at 2039 keV. This talk gives an account of the competing design options under investigation in the Gerda collaboration. The design options using photomultiplier tubes (PMT) and silicon photomultipliers (SiPM) are discussed, together with their expected performance from Monte Carlo simulations. In addition, the progress of development is reported, along with the design criteria for light instrumentation in Gerda.

  12. Demonstration and comparison of photomultiplier tubes at liquid Argon temperature

    International Nuclear Information System (INIS)

    Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photomultiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics K.K. Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R and D program of the WArP Collaboration. During these tests the Hamamatsu PMTs showed excellent performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.

  13. Electron density measurements of high pressure argon surface wave plasmas

    International Nuclear Information System (INIS)

    The electron density of an argon standing surface wave plasma has been measured from Stark broadening of the hydrogen H/sub beta/ (4861A) line. The experimental setup, consisting of two coaxial cavities, was similar to that reported by Rogers and Asmussen. The plasma was generated by 45 watts per cavity of CW, 2.54 GHz microwave power in a 6 mm O.D. (4 mm I.D.) quartz tube. Experimental argon gas pressure varied from 50 torr to over one atmosphere. Small amounts (1-5%) of hydrogen added to the argon plasma were found to shorten the plasma by as much as 80%. Thus, the Stark measurements were made using trace amounts of hydrogen. The line width of H/sub beta/ was measured with a 1 meter Czerny-Turner grating spectrometer. The Stark broadening measurements revealed that the electron density is between 1013 and 1014 electrons/cc for a pressure range of 50 to 1000 torr. These measurements agree very well with the electron density determined from the wavelength of standing surface waves. The volume of the plasma was also measured photographically and average plasma power densities (absorbed power in the plasma divided by the plasma volume) was calculated

  14. MARLEY: Model of Argon Reaction Low Energy Yields

    Science.gov (United States)

    Gardiner, Steven; Bilton, Kyle; Grant, Christopher; Pantic, Emilija; Svoboda, Robert

    2015-10-01

    Core-collapse supernovae are sources of tremendous numbers of neutrinos with energies of up to about 50 MeV. In recent years, there has been growing interest in building detectors that are sensitive to supernova neutrinos. Such detectors can provide information about the initial stages of stellar collapse, early warning signals for light emission from supernovae, and opportunities to study neutrino oscillation physics over astronomical distances. In an effort to enable supernova neutrino detection in next-generation experiments like DUNE, the CAPTAIN collaboration plans to make the first direct measurement of cross sections for neutrino interactions on argon in the supernova energy regime. To help predict neutrino event signatures in the CAPTAIN liquid argon time projection chamber (LArTPC), we have developed a first-of-its-kind Monte Carlo event generator called MARLEY (Model of Argon Reaction Low Energy Yields). This generator attempts to model the complicated nuclear structure dependence of low-energy neutrino-nucleus reactions in sufficient detail for use in LArTPC simulations. In this talk we present some preliminary results calculated using MARLEY and discuss how the current version of the generator may be improved and expanded.

  15. Isotopic fractionation of argon during stepwise release from shungite

    International Nuclear Information System (INIS)

    In previous attempts to determine the 40Ar/36Ar ratio in the ancient atmosphere, the only direct measurement yielding a value below the atmospheric value of today is for argon released at low temperatures from a pre-Cambrian shungite, an amorphous carbon mineral The present work confirms a low value for 40Ar/36Ar in gas released from a type I shungite at low temperatures. But quantitative scrutiny of the accompanying 38AR/36Ar ratios and the enhanced ratio of 40Ar/36Ar for the fractions released at high temperatures shows convincingly that the effect seen here is an artifact of the stepwise heating and the argon diffusion mobilized thereby. The low 40Ar/36Ar previously obtained is very likely from the same cause rather than reflecting the isotopic composition of the pre-Cambrian atmosphere. The vitreous character of and the sharp, conchoidal fractures seen in the specimens of type I shungite suggest that the substance may exhibit simple volume diffusion over macroscopic dimensions as glasses do. If so, the diffusion parameters (D infinitely = 3 x 10-4 cm2/s and E = 11 kcal/mole) obtained from the data imply rapid exchange with the atmosphere for any argon initially trapped in centimenter-thick veins of the material. (orig.)

  16. Isotopic fractionation of argon during stepwise release from shungite

    Science.gov (United States)

    Rison, W.

    1980-05-01

    It is noted that in previous attempts to determine the Ar-40/Ar-36 ratio in the ancient atmosphere, the only direct measurement yielding a value below the atmospheric value of today is for argon released at low temperatures from a pre-Cambrian shungite. In the present work, a low value for Ar-40/Ar-36 in gas released from a type I shungite at low temperatures is confirmed. Attention is given to a study of the accompanying Ar-38/Ar-36 ratios and the enhanced ratio of Ar-40/Ar-36 for the fractions released at high temperatures which shows that the effect observed is a result of the stepwise heating and the argon diffusion mobilized thereby. It is suggested that the low Ar-40/Ar-36 obtained in the past is from the same source rather than reflecting the isotropic composition of the pre-Cambrian atmosphere, and that the type I shungite may exhibit simple volume diffusion over macroscopic dimensions as glasses do. It is concluded that if this is so, the diffusion parameters obtained from the data would imply rapid exchange with the atmosphere for any argon initially trapped in the veins of the material.

  17. ARAPUCA a new device for liquid argon scintillation light detection

    International Nuclear Information System (INIS)

    We present a totally innovative device for the detection of liquid argon scintillation light, that has been named ARAPUCA (Argon R and D Advanced Program at UniCAmp). It is composed of a passive light collector and of active devices. The latters are standard SiPMs that operate at liquid argon temperature, while the passive collector is based on a new technology, never explored in this field before. It is a photon trap, that allows to collect light with extremely high efficiency. The total detection efficiency of the device can be tuned by modifying the ratio between the area of the active devices (SiPM) and the area of the optical window. For example, it will allow to reach a detection efficiency at the level of 1% on a surface of 50 × 50 cm2 with an active coverage of 2 × 2 cm2 (two/three large area SiPM). It is also a cheap device, since the major part of its cost is represented by the active devices. For these reason this appears to be the ideal device for scintillation light detection in large Time Projection Chambers. With appropriate modifications it can be used also in next generation Dark Matter detectors

  18. Demonstration and comparison of photomultiplier tubes at liquid Argon temperature

    Science.gov (United States)

    Acciarri, R.; Antonello, M.; Boffelli, F.; Cambiaghi, M.; Canci, N.; Cavanna, F.; Cocco, A. G.; Deniskina, N.; Di Pompeo, F.; Fiorillo, G.; Galbiati, C.; Grandi, L.; Kryczynski, P.; Meng, G.; Montanari, C.; Palamara, O.; Pandola, L.; Perfetto, F.; Piano Mortari, G. B.; Pietropaolo, F.; Raselli, G. L.; Rubbia, C.; Segreto, E.; Szelc, A. M.; Triossi, A.; Ventura, S.; Vignoli, C.; Zani, A.

    2012-01-01

    Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photomultiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics K.K. Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these tests the Hamamatsu PMTs showed excellent performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.

  19. Metal clusters on supported argon layers; Metallcluster auf dielektrischen Substraten

    Energy Technology Data Exchange (ETDEWEB)

    Faber, Bernhard

    2011-10-21

    The deposition of small sodium clusters on supported Ar(001)-surfaces is simulated. Theoretical description is achieved by a hierarchical model consisting of time-dependent DFT and molecular dynamics. The valence electrons of the sodium atoms are considered by Kohn-Sham-Scheme with self interaction correction. The interaction of argon atoms and sodium ions is described by atom-atom potentials whereas the coupling to the QM electrons is done by local pseudo-potentials. A decisive part of the model is the dynamical polarizability of the rare-gas atoms. The optional metal support is considered by the method of image charges. The influence of the forces caused by image charges and the influence of the number of argon monolayers on structure, optical response and deposition dynamics of Na{sub 6} and Na{sub 8} is investigated. There is very little influence on cluster structure and only a small shift of the cluster perpendicular to the surface. Concerning optical response the position of the Mie plasmon peak stays robust whereas the details of spectral fragmentation react very sensitively to changes. The forces caused by image charges of the metal support play only a little role with the dynamics of deposition while the thickness of the argon surface strongly influences the dissipation. (orig.)

  20. Status of the ATLAS Liquid Argon Calorimeter and its Performance

    CERN Document Server

    Barillari, T; The ATLAS collaboration

    2011-01-01

    The ATLAS experiment is designed to study the proton-proton collisions produced at the LHC with a centre-of-mass energy of 14 TeV. Liquid argon (LAr) sampling calorimeters are used in ATLAS for all electromagnetic calorimetry covering the pseudorapidity region |eta|<3.2, as well as for hadronic calorimetry from |eta|=1.4 to |eta|=4.8. The calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic (EMEC), hadronic (HEC) and forward (FCAL) calorimeters. The lead-liquid argon sampling technique with an accordion geometry was chosen for the barrel electromagnetic calorimeter (EMB) and adapted to the endcap (EMEC). This geometry allows a uniform acceptance over the whole azimuthal range without any gap. The hadronic endcap calorimeter (HEC) uses a copper-liquid argon sampling technique with plate geometry and is subdivided into two wheels in depth per end-cap. Finally, the forward calorimeter (FCAL) is composed of three modules featuring cylindrical electrodes ...

  1. ARAPUCA a new device for liquid argon scintillation light detection

    Science.gov (United States)

    Machado, A. A.; Segreto, E.

    2016-02-01

    We present a totally innovative device for the detection of liquid argon scintillation light, that has been named ARAPUCA (Argon R&D Advanced Program at UniCAmp). It is composed of a passive light collector and of active devices. The latters are standard SiPMs that operate at liquid argon temperature, while the passive collector is based on a new technology, never explored in this field before. It is a photon trap, that allows to collect light with extremely high efficiency. The total detection efficiency of the device can be tuned by modifying the ratio between the area of the active devices (SiPM) and the area of the optical window. For example, it will allow to reach a detection efficiency at the level of 1% on a surface of 50 × 50 cm2 with an active coverage of 2 × 2 cm2 (two/three large area SiPM). It is also a cheap device, since the major part of its cost is represented by the active devices. For these reason this appears to be the ideal device for scintillation light detection in large Time Projection Chambers. With appropriate modifications it can be used also in next generation Dark Matter detectors.

  2. Membrane chloride transport measured using a chloride-sensitive fluorescent probe

    International Nuclear Information System (INIS)

    Transport of chloride across cell membranes through exchange, cotransport, or conductive pathways is a subject of great biological importance. Current methods of measurement are restricted in their sensitivity, time resolution, and applicability. A new transport measurement technique has been developed on the basis of the fluorescence quenching by chloride of the dye 6-methoxy-N-(3-sulfopropyl)quinolinium (SPQ). SPQ fluorescence quenching by chloride is rapid and sensitive, with a greater than 50% decrease in fluorescence at 10 mM chloride. SPQ fluorescence is not altered by other physiological anions or by pH and can be used to measure both neutral and conductive transport processes. The high water solubility and membrane permeability properties of SPQ make it ideal for use in both membrane vesicles and cells. Chloride transport determined with SPQ was validated by measurement of erythrocyte chloride/anion exchange and membrane vesicle chloride conductance using 35SO4 uptake

  3. Roles of argon seeding in energy confinement and pedestal structure in JT-60U

    International Nuclear Information System (INIS)

    The mechanism of improving energy confinement with argon seeding at high density has been investigated in JT-60U. Better confinement is sustained at high density by argon seeding accompanied by higher core and pedestal temperatures. The electron density profiles become flatter with increasing density in conventional H-mode plasmas, whereas peaked density profiles are maintained with argon seeding. Density peaking and dilution effects lower the pedestal density at a given averaged density. The pedestal density in the argon seeded plasmas, which is lower than that in plasmas with deuterium puff, enables the pedestal temperature to be higher, whereas the increase in the pedestal pressure with argon seeding is small. High pedestal temperature is a boundary condition for high core temperature through profile stiffness, which leads to better confinement with argon seeding. The density peaking is a key factor of sustaining better confinement in argon seeded H-mode plasmas. The radiative loss power density is predominantly enhanced in the edge region by argon puff. The role of argon seeding in the pedestal characteristics has also been examined. The pedestal width becomes larger continuously with edge collisionality, but is nearly independent of the presence of argon seeding. (paper)

  4. Argon-41 production and evolution at the Oregon State University TRIGA Reactor (OSTR)

    International Nuclear Information System (INIS)

    In this study, argon-41 concentrations were measured at various locations within the reactor facility to assess the accuracy of models used to predict argon-41 evolution from the reactor tank, and to determine the relationship between argon gas evolution from the tank and subsequent argon-41 concentrations throughout the reactor room. In particular, argon-41 was measured directly above the reactor tank with the reactor tank lids closed, at other accessible locations on the reactor top with the tank lids both closed and open, and at several locations on the first floor of the reactor room. These measured concentrations were then compared to values calculated using a modified argon-41 production and evolution model for TRIGA reactor tanks and ventilation values applicable to the OSTR facility. The modified model was based in part on earlier TRIGA models for argon-41 production and release, but added features which improved the agreement between predicted and measured values. The approximate dose equivalent rate due to the presence of argon-41 in reactor room air was calculated for several different locations inside the OSTR facility. These dose rates were determined using the argon-41 concentration measured at each specific location, and were subsequently converted to a predicted quarterly dose equivalent for each location based on the reactor's operating history. The predicted quarterly dose equivalent values were then compared to quarterly doses measured by film badges deployed as dose-integrating area radiation monitors at the locations of interest. The results indicate that the modified production and evolution model is able to predict argon-41 concentrations to within a factor of ten when compared to the measured data. Quarterly dose equivalents calculated from the measured argon-41 concentrations and the reactor's operating history seemed consistent with results obtained from the integrating area radiation monitors. Given the argon-41 concentrations measured

  5. Chloride Transport in Undersea Concrete Tunnel

    Directory of Open Access Journals (Sweden)

    Yuanzhu Zhang

    2016-01-01

    Full Text Available Based on water penetration in unsaturated concrete of underwater tunnel, a diffusion-advection theoretical model of chloride in undersea concrete tunnel was proposed. The basic parameters including porosity, saturated hydraulic conductivity, chloride diffusion coefficient, initial water saturation, and moisture retention function of concrete specimens with two water-binder ratios were determined through lab-scale experiments. The variation of chloride concentration with pressuring time, location, solution concentration, initial saturation, hydraulic pressure, and water-binder ratio was investigated through chloride transport tests under external water pressure. In addition, the change and distribution of chloride concentration of isothermal horizontal flow were numerically analyzed using TOUGH2 software. The results show that chloride transport in unsaturated concrete under external water pressure is a combined effect of diffusion and advection instead of diffusion. Chloride concentration increased with increasing solution concentration for diffusion and increased with an increase in water pressure and a decrease in initial saturation for advection. The dominant driving force converted with time and saturation. When predicting the service life of undersea concrete tunnel, it is suggested that advection is taken into consideration; otherwise the durability tends to be unsafe.

  6. Shelf life of unrefrigerated succinylcholine chloride injection.

    Science.gov (United States)

    Boehm, J J; Dutton, D M; Poust, R I

    1984-02-01

    The shelf life of succinylcholine chloride injection at several pH values when stored at room temperature was evaluated. Solutions containing 20 mg/ml of succinylcholine chloride were stored at 25 and 40 degrees C. The reaction was studied at pH values ranging from 3.0 to 4.5. At two-week intervals, the solutions were assayed by high-pressure liquid chromatography. The initial amount of succinylcholine chloride in all samples was 100.1 +/- 2.37% of label claim. Hydrolysis of succinylcholine chloride in unbuffered solutions followed apparent zero-order kinetics. The pH range of maximum stability was found to be from 3.75 to 4.50. Succinylcholine chloride decomposed at a considerably higher rate at 40 degrees C. Allowing for the effects of pH adjustment during manufacture and degradation during shipping, losses of 7.0% and 9.0% potency can be expected after storage at 25 degrees C for four and six weeks, respectively. Succinylcholine Chloride Injection, USP, should be stored in the refrigerator; if unbuffered succinylcholine chloride injection complying with USP pH limits must be stored at room temperature, it should not be kept for longer than four weeks. PMID:6702837

  7. Factors influencing chloride deposition in a coastal hilly area and application to chloride deposition mapping

    Directory of Open Access Journals (Sweden)

    H. Guan

    2010-05-01

    Full Text Available Chloride is commonly used as an environmental tracer for studying water flow and solute transport in the environment. It is especially useful for estimating groundwater recharge based on the commonly used chloride mass balance (CMB method. Strong spatial variability in chloride deposition in coastal areas is one difficulty encountered in appropriately applying the method. A high-resolution bulk chloride deposition map in the coastal region is thus needed. The aim of this study is to construct a chloride deposition map in the Mount Lofty Ranges (MLR, a coastal hilly area of approximately 9000 km2 spatial extent in South Australia. We examined geographic (related to coastal distance, orographic, and atmospheric factors that may influence chloride deposition, using partial correlation and regression analyses. The results indicate that coastal distance, elevation, as well as terrain aspect and slope, appear to be significant factors controlling chloride deposition in the study area. Coastal distance accounts for 70% of spatial variability in bulk chloride deposition, with elevation, terrain aspect and slope an additional 15%. The results are incorporated into a de-trended residual kriging model (ASOADeK to produce a 1 km×1 km resolution bulk chloride deposition and concentration maps. The average uncertainty of the deposition map is about 20–30% in the western MLR, and 40–50% in the eastern MLR. The maps will form a useful basis for examining catchment chloride balance for the CMB application in the study area.

  8. Chloride substitution in sodium borohydride

    Science.gov (United States)

    Ravnsbæk, Dorthe B.; Rude, Line H.; Jensen, Torben R.

    2011-07-01

    The dissolution of sodium chloride and sodium borohydride into each other resulting in formation of solid solutions of composition Na(BH 4) 1- xCl x is studied. The dissolution reaction is facilitated by two methods: ball milling or combination of ball milling and annealing at 300 °C for three days of NaBH 4-NaCl samples in molar ratios of 0.5:0.5 and 0.75:0.25. The degree of dissolution is studied by Rietveld refinement of synchrotron radiation powder X-ray diffraction (SR-PXD) data. The results show that dissolution of 10 mol% NaCl into NaBH 4, forming Na(BH 4) 0.9Cl 0.1, takes place during ball milling. A higher degree of dissolution of NaCl in NaBH 4 is obtained by annealing resulting in solid solutions containing up to 57 mol% NaCl, i.e. Na(BH 4) 0.43Cl 0.57. In addition, annealing results in dissolution of 10-20 mol% NaBH 4 into NaCl. The mechanism of the dissolution during annealing and the decomposition pathway of the solid solutions are studied by in situ SR-PXD. Furthermore, the stability upon hydrogen release and uptake were studied by Sieverts measurements.

  9. Amperometric Sensor for Detection of Chloride Ions

    OpenAIRE

    Rene Kizek; Petr Babula; Jaromir Hubalek; Vojtech Adam; Libuse Trnkova

    2008-01-01

    Chloride ion sensing is important in many fields such as clinical diagnosis, environmental monitoring and industrial applications. We have measured chloride ions at a carbon paste electrode (CPE) and at a CPE modified with solid AgNO3, a solution of AgNO3 and/or solid silver particles. Detection limits (3 S/N) for chloride ions were 100 μM, 100 μM and 10 μM for solid AgNO3, solution of AgNO3 and/or solid silver particles, respectively. The CPE modified with silver particles is the mo...

  10. Binary Nucleation of Water and Sodium Chloride

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Thomas [Institute of Thermomechanics ASCR, Prague, Czech Republic; Marsik, Frantisek [Institute of Thermomechanics ASCR, Prague, Czech Republic; Palmer, Donald [ORNL

    2005-01-01

    Nucleation processes in the binary water-sodium chloride system are investigated in the sense of the classical nucleation theory (CNT). The CNT is modified to be able to handle the electrolytic nature of the system and is employed to investigate the acceleration of the nucleation process due to the presence of sodium chloride in the steam. This phenomenon, frequently observed in the Wilson zone of steam turbines, is called early condensation. Therefore, the nucleation rates of the water-sodium chloride mixture are of key importance in the power cycle industry.

  11. The molecular interfacial structure and plasticizer migration behavior of "green" plasticized poly(vinyl chloride).

    Science.gov (United States)

    Zhang, Xiaoxian; Li, Yaoxin; Hankett, Jeanne M; Chen, Zhan

    2015-02-14

    Tributyl acetyl citrate (TBAC), a widely-used "green" plasticizer, has been extensively applied in products for daily use. In this paper, a variety of analytical tools including sum frequency generation vibrational spectroscopy (SFG), coherent anti-Stokes Raman spectroscopy (CARS), contact angle goniometry (CA), and Fourier transform infrared spectroscopy (FTIR) were applied together to investigate the molecular structures of TBAC plasticized poly(vinyl chloride) (PVC) and the migration behavior of TBAC from PVC-TBAC mixtures into water. We comprehensively examine the effects of oxygen and argon plasma treatments on the surface structures of PVC-TBAC thin films containing various bulk percentages of plasticizers and the leaching behavior of TBAC into water. It was found that TBAC is a relatively stable PVC plasticizer compared to traditional non-covalent plasticizers but is also surface active. Oxygen plasma treatment increased the hydrophilicity of TBAC-PVC surfaces, but did not enhance TBAC leaching. However, argon plasma treatment greatly enhanced the leaching of TBAC molecules from PVC plastics to water. Based on our observations, we believe that oxygen plasma treatment could be applied to TBAC plasticized PVC products to enhance surface hydrophilicity for improving the biocompatibility and antibacterial properties of PVC products. The structural information obtained in this study will ultimately facilitate a molecular level understanding of plasticized polymers, aiding in the design of PVC materials with improved properties. PMID:25579625

  12. Catastrophic event modeling. [lithium thionyl chloride batteries

    Science.gov (United States)

    Frank, H. A.

    1981-01-01

    A mathematical model for the catastrophic failures (venting or explosion of the cell) in lithium thionyl chloride batteries is presented. The phenomenology of the various processes leading to cell failure is reviewed.

  13. Monoclonal antibodies to the apical chloride channel in Necturus gallbladder inhibit the chloride conductance.

    OpenAIRE

    Finn, A L; Tsai, L M; Falk, R J

    1989-01-01

    Monoclonal antibodies raised by injecting Necturus gallbladder cells into mice were tested for their ability to inhibit the apical chloride conductance induced by elevation of cellular cAMP. Five of these monoclonal antibodies bound to the apical cells, as shown by indirect immunofluorescence microscopy, and inhibited the chloride conductance; one antibody that bound only to subepithelial smooth muscle, by indirect immunofluorescence microscopy, showed no inhibition of chloride transport. The...

  14. Factors influencing chloride deposition in a coastal hilly area and application to chloride deposition mapping

    OpenAIRE

    H. Guan; Love, A. J.; C. T. Simmons; A. S. Kayaalp

    2009-01-01

    Chloride is commonly used as an environmental tracer for studying water flow and solute transport in the environment. It is especially useful for estimating groundwater recharge based on the commonly used chloride mass balance (CMB) method. Strong spatial variability in chloride deposition in coastal areas is one difficulty encountered in appropriately applying the CMB approach. Furthermore, intensive vegetation clearance for agriculture, for example during the European settlement in many...

  15. Telomerization of Vinyl Chloride with Chloroform Initiated by Ferrous Chloride-Dimethylacetamide under Ultrasonic Conditions

    Directory of Open Access Journals (Sweden)

    Hua Qian

    2015-01-01

    Full Text Available Telomerization of vinyl chloride with chloroform was investigated using ferrous chloride-dimethylacetamide system, and 42.1% yield, more than four times the one reported before, was achieved. The addition of ultrasound further improved the reaction and yield was raised to 51.9% with trace byproducts at highly reduced reaction time and temperature. Ferrous chloride-dimethylacetamide under ultrasonic irradiation acts as a very efficient catalyst system for the 1 : 1 telomerization.

  16. Comparative effects of argon green and krypton red laser photocoagulation for patients with diabetic exudative maculopathy.

    OpenAIRE

    Khairallah, M; Brahim, R; Allagui, M.; Chachia, N

    1996-01-01

    AIMS/BACKGROUND: Focal treatment of diabetic macular oedema is usually done using a haemoglobin absorbing wave-length, such as argon green laser. This study aimed to compare photocoagulation with argon green (514 nm) and krypton red (647 nm), which is poorly absorbed by haemoglobin, in the focal treatment of patients with diabetic exudative maculopathy. METHODS: A total of 151 eyes of 78 outpatients were assigned randomly to receive either argon green (n = 79) or krypton red (n = 72) laser tr...

  17. Emission properties of an atmospheric pressure argon plasma jet excited by barrier discharge

    International Nuclear Information System (INIS)

    An atmospheric-pressure argon plasma jet is initiated by the barrier discharge in a capillary, through which argon was flown. The spectral composition of radiation emitted by the jet in the atmosphere and its variation in the space are analyzed in detail. The jet radiation spectrum is shown to be predominantly formed by spectral transitions of argon and oxygen atoms, by electron-vibrational transitions of the first positive system of nitrogen molecules N2, and by transitions of hydroxyl radical OH

  18. The effects of argon in the bioenergetics of the hamster and the rat

    Science.gov (United States)

    Tempel, G. E.; Musacchia, X. J.

    1974-01-01

    Oxygen consumption was examined in hamsters and rats exposed to normoxic mixtures of argon at 1 atm. In fasted and nonfasted animals, no marked change in O2 utilization was detectable at 22 C. However, at 7 C a significant decrease in oxygen consumption was observed where the animals were exposed in argon. The data are interpreted in terms of the greater thermal conductivity of nitrogen. The study was prompted by conflicting reports on the metabolic effects of argon and helium.

  19. The kinetics of the hydrogen chloride oxidation

    Directory of Open Access Journals (Sweden)

    Gonzalez Martinez Isai

    2013-01-01

    Full Text Available Hydrogen chloride (HCl oxidation has been investigated on technical membrane electrode assemblies in a cyclone flow cell. Influence of Nafion loading, temperature and hydrogen chloride mole fraction in the gas phase has been studied. The apparent kinetic parameters like reaction order with respect to HCl, Tafel slope and activation energy have been determined from polarization data. The apparent kinetic parameters suggest that the recombination of adsorbed Cl intermediate is the rate determining step.

  20. Estimating the chloride transport in cement paste

    OpenAIRE

    Princigallo, A.

    2012-01-01

    A method was developed to measure the diffusion coefficient of chloride ions in cement paste based on an analytical solution to Fick’s 2nd law in a cylindrical coordinate system. This natural method yielded diffusivity results within as little as a month. Testing time was reduced by exploiting the three-dimensional inward flux in the specimen. In an attempt to determine the saturation concentration, dense portland cement pastes were exposed to a concentrated chloride solution. The method prov...

  1. Argon Laser Photoablation for Treating Benign Pigmented Conjunctival Nevi

    Science.gov (United States)

    Alsharif, Abdulrahman M.; Al-Gehedan, Saeed M.; Alasbali, Tariq; Alkuraya, Hisham S.; Lotfy, Nancy M.; Khandekar, Rajiv

    2016-01-01

    Purpose: To evaluate the outcomes of argon laser photoablation of benign conjunctival pigmented nevi with different clinical presentations. Patients and Methods: This interventional case series was conducted between July 2014 and January 2015. Patients presenting with benign conjunctival nevi were included. Data were collected on the clinical features at presentation, argon laser photoablation, and follow-up at 8 and 24 weeks. Postoperative photography allowed recording of the success of each case and the overall success rate. Complete removal of conjunctival pigments was considered an absolute success. Partial pigmentation requiring repeat laser treatment was considered a qualified success. Results: There were 14 eyes (four right eyes and ten left eyes) with benign pigmented conjunctival nevi. There were three males and eight females in the study sample. The median age was 36 (25% percentile: 26 years). Three patients had bilateral lesions. The nevi were located temporally in nine eyes, nasally in three eyes, and on the inferior bulbar conjunctiva in two eyes. The mean horizontal and vertical diameters of nevi were 5 ± 2 mm and 4 ± 2.7 mm, respectively. The mean follow-up period was 5 months. Following laser treatment, no eyes had subconjunctival hemorrhage, infection, scarring, neovascularization, recurrence, or corneal damage. The absolute success rate of laser ablation was 79%. Three eyes with elevated nevi had one to three sessions of laser ablation resulting in a qualified success rate of 100%. Conclusions: Argon laser ablation was a safe and effective treatment for the treatment of selective benign pigmented conjunctival nevi in Arab patients. PMID:27555708

  2. Sodium aerosol formation in an argon flow over hot sodium

    International Nuclear Information System (INIS)

    Vapour evaporation, which partly forms aerosol, occurs when a cold gas flows over a hot liquid. A previous well-mixed model is extended to predict the final vapour plus aerosol content of such a flow in terms of its initial and final temperatures. The predictions are compared to results of the Copacabana II experiment in which argon passed over a sodium pool. Agreement is obtained for the final sodium density at moderate flow rates, and physical reasons are given as to why deviations occur at low and high flow rates. (author)

  3. Performance of the TGT liquid argon calorimeter and trigger system

    International Nuclear Information System (INIS)

    A novel concept of a liquid argon calorimeter, the 'Thin Gap Turbine' (TGT) calorimeter, is presented. A TGT test module, equipped with specially developed cold front-end electronics in radiation hard GaAs technology, has been operated in a particle beam. Results on its performance are given. A 40 MHz FADC system with a 'circular data store' and standalone readout and playback capability has been developed to test the properties of the TGT detector for trigger purposes. Results on trigger efficiency, response and energy resolution are given. 12 refs., 21 figs., 6 tabs

  4. Optical fiber read-out for liquid argon scintillation light

    CERN Document Server

    Csáthy, J Janicskó; Kratz, J; Schönert, S; Wiesinger, Ch

    2016-01-01

    In this paper we describe the performance of a light detector for Ar scintillation light made of wavelength-shifting (WLS) fibers connected to Silicon-Photomultipliers (SiPM). The setup was conceived to be used as anti-Compton veto for high purity germanium (HPGe) detectors operated directly in liquid Argon (LAr). Background suppression efficiencies for different radioactive sources were measured in a test cryostat with about 800 kg LAr. This work was part of the R\\&D effort for the GERDA experiment.

  5. HARP: high-pressure argon readout for calorimeters

    International Nuclear Information System (INIS)

    Steel tubes of approximately 8 mm O.D., filled with Argon gas to approx. 200 bar, are considered as the active element for a charge collecting sampling calorimeter readout system. The tubes are permanently sealed and operated in the ion chamber mode, with the charge collection on a one-millimeter concentric anode. We present the motivation for such a device, including Monte Carlo predictions of performance. The method of construction and signal collection are discussed, with initial results on leakage and ageing of the filling gas. A prototype electromagnetic calorimeter is described

  6. Modeling of an argon cascaded arc plasma by ANSYS FLUENT

    International Nuclear Information System (INIS)

    In this work, an argon cascaded arc plasma is simulated by the business software ANSYS FLUENT. In fact, thus plasma is a high temperature arc (plasma window) with an average temperature of 12000 °C, which can be used as a medium between high pressure and vacuum mainly due to its characteristics of high temperature. According to the simulating results, the temperature can reach as high as 11500 °C which is in great agreement with that of other reports about plasma window.

  7. Diffusion coefficient of metal vapours into rare gases. Mercury - argon

    International Nuclear Information System (INIS)

    The source information is present as well as the results of analysis and integration of data on mutual diffusion coefficient (MDC) of mercury - argon mixture at Hg concentration → 0 in 300-2500 K temperature range. Reference data on MDC for metal - inert gas binary mixtures obtained on the base of complex analysis of various information, as it exemplified by Hg-Ar pair, can be used as a part of metrological support at calibration of devices for determination MDC of gas - metal vapors

  8. Searching for dark matter with single phase liquid argon

    Science.gov (United States)

    Caldwell, Thomas S., Jr.

    The first hint that we fail to understand the nature of a large fraction of the gravitating matter in the universe came from Fritz Zwicky's measurements of the velocity distribution of the Coma cluster in 1933. Using the Virial theorem, Zwicky found that galaxies in the cluster were orbiting far too fast to remain gravitationally bound when their mass was estimated by the brightness of the visible matter. This led to the postulation that some form of non-luminous dark matter is present in galaxies comprising a large fraction of the galactic mass. The nature of this dark matter remains yet unknown over 80 years after Zwicky's measurements despite the efforts of many experiments. Dark matter is widely believed to be a beyond the Standard Model particle which brings the dark matter problem into the realm of particle physics. Supersymmetry is one widely explored extension of the Standard model, from which particles meeting the constraints on dark matter properties can naturally arise. These particles are generically termed weakly interacting massive particles (WIMPs), and are a currently favored dark matter candidate. A variety of experimental efforts are underway aimed towards direct detection of dark matter through observation of rare scattering of WIMPs in terrestrial detectors. Single phase liquid argon detectors are an appealing WIMP detection technique due to the scintillation properties of liquid argon and the scalability of the single phase approach. The MiniCLEAN dark matter detector is a single phase liquid argon scintillation scintillation detector with a 500 kg active mass. The modular design offers 4pi coverage with 92 optical cassettes, each containing TPB coated acrylic and a cryogenic photomultiplier tube. The MiniCLEAN detector has recently completed construction at SNOLAB. The detector is currently being commissioned, and will soon begin operation with the liquid argon target. Utilizing advanced pulse-shape discrimination techniques, MiniCLEAN will

  9. Penning transfer in argon-based gas mixtures

    CERN Document Server

    Sahin, O; Tapan, I; Ozmutlu, E N

    2010-01-01

    Penning transfers, a group of processes by which excitation energy is used to ionise the gas, increase the gas gain in some detectors. Both the probability that such transfers occur and the mechanism by which the transfer takes place, vary with the gas composition and pressure. With a view to developing a microscopic electron transport model that takes Penning transfers into account, we use this dependence to identify the transfer mechanisms at play. We do this for a number of argon-based gas mixtures, using gain curves from the literature.

  10. The main properties of microwave argon plasma at atmospheric pressure

    International Nuclear Information System (INIS)

    Plasma torch sustained by surface wave at atmospheric pressure is theoretically studied by means of 1D model. A steady-state Boltzmann equation in an effective field approximation coupled with a collisional-radiative model for high-pressure argon discharge is numerically solved together with Maxwell's equations for an azimuthally symmetric TM surface wave. The axial dependences of the electrons, excited atoms, atomic and molecular ions densities as well as the electron temperature, the mean power per electron and the effective electron-neutral collision frequency are determined. A strong dependence of the plasma properties on the discharge conditions and the gas temperature is obtained.

  11. Study of a Novel Concept for a Liquid Argon Calorimeter \

    CERN Multimedia

    2002-01-01

    % RD33 \\\\ \\\\ The development of a fast, highly granular and compact electromagnetic liquid argon calorimeter prototype is proposed as a generic R\\&D project for a novel concept of calorimetry in proton-proton and electron-positron collider detectors: the $^{\\prime$Thin Gap Turbine$^{\\prime}$ (TGT). The TGT calorimeter has a modular construction, is flexible in its longitudinal and transverse granularity, and offers a uniform energy response and resolution, independent of the production angle of incident particles. An important aspect of the project is the development of fast, radiation-hard front-end electronics which is operating in the cold.

  12. Intracavity frequency doubling in a wide-aperture argon laser

    International Nuclear Information System (INIS)

    The four-mirror cavity with a BBO crystal for frequency doubling in a wide-aperture argon laser is optimised. The dependences of the second-harmonic power on the displacement of a focusing mirror, the displacement of the crystal, and the discharge current are measured. These dependences are in good agreement with calculations. After optimisation, ∼1 W of UV laser radiation at 244 nm was obtained with the conversion efficiency twice as large as that for the known similar lasers. It is shown that the increase in the efficiency was achieved mainly due to the increase in the discharge-tube aperture. (nonlinear optical phenomena)

  13. High intensity, argon ion laser-jet photochemistry

    Science.gov (United States)

    Wilson, R. Marshall; Schnapp, Karlyn A.; Hannemann, Klaus; Ho, Douglas M.; Memarian, Hamid R.; Azadnia, Ardeshir; Pinhas, Allan R.; Figley, Timothy M.

    A new technique for the study of high intensity solution photochemistry has been developed. With this laser-jet technique, a high velocity microjet is irradiated with the focussed output of an argon ion laser. Under these extremely high intensity conditions, photochemically generated transient species with suitable absorption properties are excited further and produce relatively large amounts of photoproducts which are not observed under low intensity conditions. The application of this laser-jet technique in the study of the photochemistry of radicals, biradicals, photoenols and the higher excited states of carbonyl and polycyclic aromatic compounds is described.

  14. The main properties of microwave argon plasma at atmospheric pressure

    Science.gov (United States)

    Benova, E.; Pencheva, M.

    2010-01-01

    Plasma torch sustained by surface wave at atmospheric pressure is theoretically studied by means of 1D model. A steady-state Boltzmann equation in an effective field approximation coupled with a collisional-radiative model for high-pressure argon discharge is numerically solved together with Maxwell's equations for an azimuthally symmetric TM surface wave. The axial dependences of the electrons, excited atoms, atomic and molecular ions densities as well as the electron temperature, the mean power per electron and the effective electron-neutral collision frequency are determined. A strong dependence of the plasma properties on the discharge conditions and the gas temperature is obtained.

  15. The main properties of microwave argon plasma at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Benova, E; Pencheva, M, E-mail: benova_phys@deo.uni-sofia.b [Department for Language Teaching and International Students, University of Sofia, 27 Kosta Loulchev Street, BG-1111 Sofia (Bulgaria)

    2010-01-01

    Plasma torch sustained by surface wave at atmospheric pressure is theoretically studied by means of 1D model. A steady-state Boltzmann equation in an effective field approximation coupled with a collisional-radiative model for high-pressure argon discharge is numerically solved together with Maxwell's equations for an azimuthally symmetric TM surface wave. The axial dependences of the electrons, excited atoms, atomic and molecular ions densities as well as the electron temperature, the mean power per electron and the effective electron-neutral collision frequency are determined. A strong dependence of the plasma properties on the discharge conditions and the gas temperature is obtained.

  16. Laser-induced vibrational dynamics of ozone in solid argon

    DEFF Research Database (Denmark)

    Hansen, Flemming Yssing; Amstrup, B.; Henriksen, Niels Engholm

    1997-01-01

    We consider the vibrational dynamics, induced by an intense infrared laser pulse, in an ozone molecule with isotopic substitution, that is, (OOO)-O-16-O-16-O-18 and compare the dynamics in the gas phase and in solid ar on. not perturbed by argon on a time-scale of a few picoseconds and selective...... bond-breaking in the molecule should be possible following the same laser control scheme as suggested in the gas phase. (C) 1997 Elsevier Science B.V....

  17. Electron transport in argon in crossed electric and magnetic fields

    Science.gov (United States)

    Ness; Makabe

    2000-09-01

    An investigation of electron transport in argon in the presence of crossed electric and magnetic fields is carried out over a wide range of values of electric and magnetic field strengths. Values of mean energy, ionization rate, drift velocity, and diffusion tensor are reported here. Two unexpected phenomena arise; for certain values of electric and magnetic field we find regions where the swarm mean energy decreases with increasing electric fields for a fixed magnetic field and regions where swarm mean energy increases with increasing magnetic field for a fixed electric field. PMID:11088933

  18. Ionization coefficients for argon in a micro-discharge

    International Nuclear Information System (INIS)

    Ionization coefficients are measured for electrons in a dc micro-discharge in argon from optical emission profiles. The micro-discharge is operated in the Townsend regime between two parallel-plate electrodes. Axial profiles of emission are obtained with sufficient resolution to provide spatial ionization coefficients. The measured coefficients agree very well with the data obtained from other sources, indicating the operation of the discharge in the Townsend regime and also that Townsend mechanisms do not need extension to describe such discharges. (paper)

  19. Kinetic modeling of the Townsend breakdown in argon

    Science.gov (United States)

    Macheret, S. O.; Shneider, M. N.

    2013-10-01

    Kinetic modeling of the Townsend breakdown in argon was performed in the "forward-back" approximation. The kinetic model was found to adequately describe the left branch of the Paschen curve, and the important role of ionization by fast ions and atoms near the cathode, as well as the increase in secondary emission coefficient in strong electric fields described in the literature, was confirmed. The modeling also showed that the electron energy distribution function develops a beam of high-energy electrons and that the runaway effect, i.e., the monotonic increase of the mean electron energy with the distance from the cathode, occurs at the left branch of the Paschen curve.

  20. Ionization coefficients for argon in a micro-discharge

    Science.gov (United States)

    Kuschel, Thomas; Stefanović, Ilija; Malović, Gordana; Marić, Dragana; Petrović, Zoran Lj

    2013-08-01

    Ionization coefficients are measured for electrons in a dc micro-discharge in argon from optical emission profiles. The micro-discharge is operated in the Townsend regime between two parallel-plate electrodes. Axial profiles of emission are obtained with sufficient resolution to provide spatial ionization coefficients. The measured coefficients agree very well with the data obtained from other sources, indicating the operation of the discharge in the Townsend regime and also that Townsend mechanisms do not need extension to describe such discharges.

  1. Argon Analyses of Lherzolic Shergottites Y984028 and Y000097

    Science.gov (United States)

    Park, J.; Nyquist, L. E.; Bogard, D. D.; Garrison, D. H.; Shih, C.-Y.; Mikouchi, T.; Misawa, K.

    2010-01-01

    Antarctic Martian meteorites Yamato (Y) 984028 and Y000027/47/97 have similar textures, mineralogy, chemistry, and isotopic composition and are possibly paired. We analyzed the argon isotopic composition of Y984028 whole rock (WR) and pyroxene mineral separates (Px) in order to evaluate their trapped Ar components and compare with Y000097 Ar data. WR and Px yield an apparent Ar-39-Ar-40 age spectra of roughly 2 Ga, much older than the crystallization age determined by other isotopic techniques. Sm-Nd and Rb-Sr ages for Y984028 are approximately 170 Ma. This discrepancy is likely the byproduct of several coexisting Ar components, such as radiogenic 40Ar*, cosmogenic Ar, and trapped Ar from the multiple minerals, as well as multiple source origins. Similarly, the reported Ar-39-Ar-40 age of Y000097 is approximately 260 Ma with a Rb-Sr age of 147+/- 28 Ma and a Sm-Nd age of 152 +/- 13 Ma [4]. Apparently Ar-Ar ages of both Y984028 and Y000097 show trapped Ar components. Stepwise temperature extractions of Ar from Y984028 Px show several Arcomponents released at different temperatures. For example, intermediate temperature data (800-1100 C) are nominally consistent with the Sm-Nd and Rb-Sr radiometric ages (approximately 170 Ma) with an approximately Martian atmosphere trapped Ar composition with a Ar-40-Ar-36 ratio of approximately 1800. Based on K/Ca distribution, we know that Ar-39 at both lower and intermediate temperatures is primarily derived from plagioclase and olivine. Argon released during higher temperature extractions (1200-1500 C), however, differs significantly. The thermal profile of argon released from Martian meteorites is complicated by multiple sources, such as Martian atmosphere, Martian mantle, inherited Ar, terrestrial atmosphere, cosmogenic Ar. Obviously, Ar release at higher temperatures from Px should contain little terrestrial atmospheric component. Likewise, Xe-129/Xe-132 from high temperature extractions (1200-1800 C) gives a value above that

  2. Above threshold ionization of Argon atoms by multicolor XUV radiation

    International Nuclear Information System (INIS)

    We analyse theoretically the Argon photoelectron spectra produced by strong and extreme ultraviolet radiation of six colors: from the 11th to the 16th harmonics of ω0 (800nm). In particular we concentrate in the range of the spectra where absorption of two photons occurs. The combination of photons of different frequencies results in eleven peaks that are separated by ω0. We point out that their relative intensities are very sensitive to the laser pulse parameters and target description. We also compare the theoretical description with experimental results finding good qualitative agreement

  3. Charges recombination in α particle tracks in argon

    International Nuclear Information System (INIS)

    The creation and evolution of (neutral) excited states and ionized states in α particle tracks in high pressure argon are studied. The main features of recently published experimental results on the recombination luminescence can be explained and a track model is proposed. Details are given on the track radius, on the electrons thermallization, and on collisions between electrons and triplet excited states. The most important result is that at high pressure and high electron and ion densities a collective electron-ion recombination is possible, that is more efficient that the well known dissociative recombination

  4. Activation of copper by nitrogen and argon beams

    Energy Technology Data Exchange (ETDEWEB)

    Chetvertkova, Vera [IAP, Goethe-University, Frankfurt am Main (Germany); GSI Darmstadt (Germany); Mustafin, Edil; Strasik, Ivan [GSI Darmstadt (Germany); Belousov, Anton [TU Darmstadt (Germany); Latysheva, Ludmila; Sobolevsky, Nikolai [INR RAS, Moscow (Russian Federation); Ratzinger, Ulrich [IAP, Goethe-University, Frankfurt am Main (Germany)

    2012-07-01

    Monte Carlo transport codes are widely used for various purposes in nuclear physics, radiation protection, medical applications, accelerator design etc. Code verification by experiments is needed to be sure that the codes give accurate results. New data on the activation of copper by a nitrogen beam of 500 MeV/u is presented and compared with FLUKA and SHIELD simulation results. The activation of copper by a nitrogen beam is compared to activation by an argon beam and respective simulations. This gives a chance to see the accuracy of the codes at different projectile masses. Correspondences and discrepancies of calculations and experiments are discussed.

  5. Electron drift velocity in argon-methane mixture

    International Nuclear Information System (INIS)

    Described are the results of a series of measurements of electron drift velocity taken with samples of chemically pure grade gas mixture of Ar-10% CH4 (N2222O<2 ppm). The measured drift velocity is plotted as a function of the ratio of electric field to pressure in the range from 0.05 to 0.8 V/cmxtorr. The measurements are reproducible only to within 4%. The results of numerical calculations employing the well-established argon elastic and methane elastic and inelastic cross sections are also included. The disagreement from the present experimental results, and from those obtained elsewhere, is rather puzzling

  6. Study of a novel electromagnetic liquid argon calorimeter TGT

    International Nuclear Information System (INIS)

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a test beam exposure. 15 refs., 16 figs., 2 tabs

  7. Effect of Chloride Type on Penetration of Chloride Ions in Concrete

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The influence of chloride type on the diffusivity of chloride ions in concrete was studied by experiment. The result shows that the glectric resistance of concrete and the chloride diffusion coefficient are influenced by chloride type. For the same water/cement ratio (W/C), the diffusion coefficient D in KCl solution is larger than that in NaCl solution; however, the concrete resistance in KCl solution is smaller than that in NaCl solution. The experimental result is analyzed with theory of diffusion.

  8. 49 CFR 179.102-17 - Hydrogen chloride, refrigerated liquid.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Hydrogen chloride, refrigerated liquid. 179.102-17...) § 179.102-17 Hydrogen chloride, refrigerated liquid. Each tank car used to transport hydrogen chloride... on or after March 16, 2009 used for the transportation of hydrogen chloride, refrigerated...

  9. 21 CFR 178.3290 - Chromic chloride complexes.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Chromic chloride complexes. 178.3290 Section 178... SANITIZERS Certain Adjuvants and Production Aids § 178.3290 Chromic chloride complexes. Myristo chromic chloride complex and stearato chromic chloride complex may be safely used as release agents in the...

  10. Factors influencing chloride deposition in a coastal hilly area and application to chloride deposition mapping

    Directory of Open Access Journals (Sweden)

    H. Guan

    2009-09-01

    Full Text Available Chloride is commonly used as an environmental tracer for studying water flow and solute transport in the environment. It is especially useful for estimating groundwater recharge based on the commonly used chloride mass balance (CMB method. Strong spatial variability in chloride deposition in coastal areas is one difficulty encountered in appropriately applying the CMB approach. Furthermore, intensive vegetation clearance for agriculture, for example during the European settlement in many coastal areas of Australia, may have perturbed catchment chloride balance conditions for appropriate use in CMB applications. In order to deal with these issues, a high resolution chloride deposition map in the coastal region is needed. In this study, we examined geographic, orographic, and atmospheric factors influencing chloride deposition in the Mount Lofty Ranges (MLR, a coastal hilly area of approximately 9000 km2 spatial extent in South Australia, using partial correlation and regression analyses. The results indicate that coastal distance, and terrain aspect and slope are two most significant factors controlling chloride deposition. Coastal distance accounts for 65% spatial variability in chloride deposition, with terrain aspect and slope for 8%. The deposition gradient is about 0.08 gm-2 year-1 km-1 as one progresses inland. The results are incorporated into a published de-trended residual kriging approach (ASOADeK to produce a 1 km×1 km resolution annual chloride deposition map and a bulk precipitation chloride concentration map. The average uncertainty of the deposition map is about 30% in the western MLR, and over 50% in the eastern MLR. The maps will form a very useful basis for examining catchment chloride balances for use in the CMB application in the study area.

  11. Measurements of the ratio between the transverse diffusion coefficient and the mobility for argon ions in argon

    International Nuclear Information System (INIS)

    The ratio DT/μ between the transverse diffusion coefficient and the mobility for 40Ar+ ions in argon has been determined from directly measured transverse current density distribution profiles of mass-analysed ions, as a function of the ratio E/n0 between the electric field and the gas number density in the interval 50≤E/n0≤4000 Td, at gas temperature T=294 K using a variable-length drift tube mass spectrometer. The error (two standard deviations) in the results is believed to be less than ±4% for E/n0o-values. (author)

  12. A liquid argon scintillation veto for the GERDA experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment to search for the neutrinoless double beta decay of 76Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10-3 cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  13. A liquid argon scintillation veto for the GERDA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Results of Phase I have been published in summer 2013. Currently Gerda is being upgraded to a second phase. To reach the aspired background index of ≤ 10{sup -3} cts/(keV . kg . yr) for Phase II active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. This talk focusses on the light instrumentation which is being installed in GERDA. Photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) are combined to maximize the photoelectron-yield with respect to various background sources. Monte Carlo simulations have been performed to optimize the design for background suppression and low self-induced background. First results of the prototypes and the progress of installation are reported.

  14. Compilation of electron collision excitation cross sections for neutro argon

    International Nuclear Information System (INIS)

    The present work presents a compilation and critical analysis of the available data on electron collision excitation cross sections for neutral Argon levels. This study includes: 1.- A detailed description in intermediate coupling for all the levels belonging the 20 configurations 3p''5 ns(n=4 to 12), np(n=4 to 8) and nd(n=3 to 8) of neutral Argon. 2.- Calculation of the electron collision excitation cross sections in Born and Born-Oppenheimer-Ochkur approximations for all the levels in the 14 configurations 3p''5 ns(n=4 to 7), np(n=4 to 7) and nd(n=3 to 8). 3.- Comparison and discussion of the compiled data. These are the experimental and theoretical values available from the literature, and those from this work. 4.- Analysis of the regularities and systematic behaviors in order to determine which values can be considered more reliable. It is show that the concept of one electron cross section results quite useful for this purpose. In some cases it has been possible to obtain in this way approximate analytical expressions interpolating the experimental data. 5.- All the experimental and theoretical values studied are graphically presented and compared. 6.- The last part of the work includes a listing of several general purpose programs for Atomic Physics calculations developed for this work. (Author)

  15. Model of a stationary microwave argon discharge at atmospheric pressure

    International Nuclear Information System (INIS)

    The many applications of microwave gas discharges at atmospheric pressure in various fields of science, technology and medicine require an adequate model of these discharges. Such a model is based on the electromagnetic wave's propagation properties and on the elementary processes in the discharge bulk. In contrast to the microwave discharges at low-gas pressures, where many elementary processes might be ignored because of their negligible contribution to the electron and heavy particle's balance equations, for such discharges at atmospheric pressure the consideration of a large number of collisional processes is mandatory. For the build of a successful discharge-column model one needs three important quantities, notably the power θ necessary for sustaining an electron - ion pair, electron - neutral collision frequency for momentum transfer ven, and gas temperature Tg. The first two key parameters are obtained by a collisional-radiative model of the argon at atmospheric pressure, while the microwave frequency ω/2π = 2.45 GHz, plasma column radius R, gas pressure p and gas temperature Tg are fixed external parameters determined by the experimental conditions. Here, we present a model of a capillary argon microwave plasma column with a length L ≅ 14 cm, sustained by wave power of 110 W - the model yields the longitudinal distributions of the plasma density, expended wave power, wave electric field magnitude, and complex wave number

  16. Analysis of microdischarges in asymmetric dielectric barrier discharges in argon

    International Nuclear Information System (INIS)

    Theoretical and experimental studies of two different discharge modes in asymmetric dielectric barrier discharges in argon at atmospheric pressure have been performed. The first mode appears to be the well-known filamentary microdischarge with non-striated positive column whereas the second mode is characterized by discharge instabilities and the appearance of striations. Both experiment and model calculations predict a transition from the first mode to the second mode when the applied voltage amplitude is increased above approximately 2 kV. The reliability of the employed fluid model is confirmed by comparison of the current–voltage characteristics obtained by model calculations and measurements for different applied voltage amplitudes. The results of the model calculations point out that in the second discharge mode the ionization of excited argon atoms prevents the total recombination of charge carriers between two subsequent discharge events. This leads to the occurrence of the memory from one discharge to the following one, which plays an important role in mode transition. (paper)

  17. Model of a stationary microwave argon discharge at atmospheric pressure

    Science.gov (United States)

    Zhelyazkov, I.; Pencheva, M.; Benova, E.

    2008-03-01

    The many applications of microwave gas discharges at atmospheric pressure in various fields of science, technology and medicine require an adequate model of these discharges. Such a model is based on the electromagnetic wave's propagation properties and on the elementary processes in the discharge bulk. In contrast to the microwave discharges at low-gas pressures, where many elementary processes might be ignored because of their negligible contribution to the electron and heavy particle's balance equations, for such discharges at atmospheric pressure the consideration of a large number of collisional processes is mandatory. For the build of a successful discharge-column model one needs three important quantities, notably the power θ necessary for sustaining an electron—ion pair, electron—neutral collision frequency for momentum transfer ven, and gas temperature Tg. The first two key parameters are obtained by a collisional-radiative model of the argon at atmospheric pressure, while the microwave frequency ω/2π = 2.45 GHz, plasma column radius R, gas pressure p and gas temperature Tg are fixed external parameters determined by the experimental conditions. Here, we present a model of a capillary argon microwave plasma column with a length L ≈ 14 cm, sustained by wave power of 110 W—the model yields the longitudinal distributions of the plasma density, expended wave power, wave electric field magnitude, and complex wave number.

  18. Liquid argon scintillation read-out with silicon devices

    International Nuclear Information System (INIS)

    Silicon photosensors represent a viable alternative to standard photomultipliers in fields such as communications and medical imaging. We explored the interesting possibility of using these sensors in combination with liquid argon (LAr) for astroparticle physics applications such as neutrino, dark matter and double beta decay experiments. In fact, silicon photosensors have detection efficiencies comparable with those of the highest performance PMTs and can be manufactured with high level of radiopurity. In particular within the on-going R and D activity of the SILENT project (Low background and low noise techniques for double beta decay physics funded by ASPERA) a large area SiPM (Silicon PhotoMultiplier - Hamamatsu S11828-3344M - 1.7 cm2 area) has been installed in a LAr scintillation chamber of 0.5 liters volume together with a cryogenic photomultiplier tube (Hamamatsu R11065) used as a reference. The liquid argon chamber has been exposed to many gamma sources of different energies and single photoelectron response and light yield for the SiPM and PMT have been measured and compared. In this contribution the results of the tests, and the ongoing R and D to optimize the SiPM for cryogenic and for ultralow background applications, are reported, as well as the possible application in the GERDA experiment on Double Beta Decay Searches of 76Ge

  19. Elastic properties of liquid and solid argon in nanopores.

    Science.gov (United States)

    Schappert, Klaus; Pelster, Rolf

    2013-10-16

    We have measured sorption isotherms and determined the intrinsic longitudinal elastic modulus β(Ar,ads) of nanoconfined material via ultrasonic measurements combined with a special effective medium analysis. In the liquid regime the adsorbate only contributes to the measured effective properties when the pores are completely filled and the modulus is bulklike. At partial fillings its contribution is cancelled out by the high compressibility of the vapour phase. In contrast, at lower temperatures frozen argon as well as underlying liquid surface layers cause a linear increase of the effective longitudinal modulus upon filling. During sorption the contribution of the liquid surface layers near the pore wall β(Ar,surf) increases with the thickness of the solid layers reaching the bulk value β(Ar,liquid) only in the limit of complete pore filling. We interpret this effect as due to the gradual stiffening of the solid argon membrane. The measurements and their analysis show that longitudinal ultrasonic waves are well suited to the study of the elastic properties and liquid-solid phase transitions in porous systems. This method should also help to detect the influence of nanoconfinement on elastic properties in further research. PMID:24057946

  20. Liquid argon scintillation read-out with silicon devices

    Science.gov (United States)

    Canci, N.; Cattadori, C.; D'Incecco, M.; Lehnert, B.; Machado, A. A.; Riboldi, S.; Sablone, D.; Segreto, E.; Vignoli, C.

    2013-10-01

    Silicon photosensors represent a viable alternative to standard photomultipliers in fields such as communications and medical imaging. We explored the interesting possibility of using these sensors in combination with liquid argon (LAr) for astroparticle physics applications such as neutrino, dark matter and double beta decay experiments. In fact, silicon photosensors have detection efficiencies comparable with those of the highest performance PMTs and can be manufactured with high level of radiopurity. In particular within the on-going R&D activity of the SILENT project (Low background and low noise techniques for double beta decay physics funded by ASPERA) a large area SiPM (Silicon PhotoMultiplier - Hamamatsu S11828-3344M - 1.7 cm2 area) has been installed in a LAr scintillation chamber of 0.5 liters volume together with a cryogenic photomultiplier tube (Hamamatsu R11065) used as a reference. The liquid argon chamber has been exposed to many gamma sources of different energies and single photoelectron response and light yield for the SiPM and PMT have been measured and compared. In this contribution the results of the tests, and the ongoing R&D to optimize the SiPM for cryogenic and for ultralow background applications, are reported, as well as the possible application in the GERDA experiment on Double Beta Decay Searches of 76Ge.

  1. Investigation of a Mercury-Argon Hot Cathode Discharge

    Science.gov (United States)

    Wamsley, Robert Charles

    Classical absorption and laser induced fluorescence (LIF) experiments are used to investigate processes in the cathode region of a Hg-Ar hot cathode discharge. The absorption and LIF measurements are used to test the qualitative understanding and develop a quantitative model of a hot cathode discharge. The main contribution of this thesis is a model of the negative glow region that demonstrates the importance of Penning ionization to the ionization balance in the negative glow. We modeled the excited argon balance equation using a Monte Carlo simulation. In this simulation we used the trapped radiative decay rate of the resonance levels and the Penning ionization rate as the dominant loss terms in the balance equation. The simulated data is compared to and found to agree with absolute excited argon densities measured in a classical absorption experiment. We found the primary production rate per unit volume of excited Ar atoms in the simulation is sharply peaked near the cathode hot spot. We used the ion production rate from this simulation and a Green's function solution to the ambipolar diffusion equation to calculate the contribution of Penning ionization to the total ion density. We compared the results of this calculation to our experimental values of the Hg ^+ densities in the negative glow. We found that Penning ionization is an important and possibly the dominant ionization process in the negative glow.

  2. Argon laser trabeculoplasty as primary therapy in open angle glaucoma

    International Nuclear Information System (INIS)

    To determine the effect of Argon Laser Trabeculoplasty (ALT) as a primary mode of therapy in reducing the intraocular Pressure (IOP) of patients diagnosed with Primary Open Angle Glaucoma (POAG). A total of 35 eyes of 35 patients with the gender distribution of 27 men and 8 women who were newly diagnosed with POAG, were included in this study. Mean age of the patients was 55.2 years with the range of 32 to 76 years. All of them were treated with argon laser trabeculoplasty as a primary mode of therapy. Intra ocular pressure was measured objectively using Goldman applanation tonometer, pre-and-post laser therapy. The pre-laser mean IOP was 27.63 mmHg (range 21-40 mmHg). The post-laser mean IOP measured at 6 months follow up was 15.5 mmHg (range 11 - 33 mmHg) with mean decrease of 12.1 mmHg. The decrease in IOP was seen in 32 eyes (95%) with no change observed in 3 (5%) eyes. The result shows a marked decline in IOP in patients with POAG who underwent ALT as a primary mode of treatment. Further studies with large sample size and longer follow-up will help in making future recommendations. (author)

  3. Dating of mineral samples through activation analysis of argon

    International Nuclear Information System (INIS)

    Mass Spectrometry has been the usual method to determine Ar concentrations in mineral samples for dating them through the 40Ar/40K ratio. This technique has been replaced since 1966 by measurement of 40Ar/39Ar ratio, after artificial production of 39Ar from the 39K(n,p)39Ar reaction produced in the fast neutron flux of a nuclear reactor. This method requires the fusion of the sample by incremental heating until reaching a temperature of 1000 deg C in order to get the total release of both argon isotopes. In principle, it should be possible to determine the 40Ar/40K ratio by activation analysis in an easier, non-destructive way, but it presents the following drawbacks: manufacture of argon standards; usual low ratio peak/Compton distribution for both peaks: 1.29 Mev and 1.52 Mev (41Ar and 42K respectively), since potassium minerals are usually very rich in sodium, manganese and chlorine; reaction 41K(n,p)41Ar induced by fast neutrons present in the thermal flux; and possible contamination of the samples and standards with atmospheric 40Ar(99.6% of elementary Ar, whose proportion in the atmosphere at sea level is 0.93%). This paper describes how these problems may be solved, also determining the limits of Ar and K concentration related to Compton distribution, in our experimental conditions. (author) 5 refs.; 1 tab

  4. Some transport properties in plasmas containing argon and fluorine

    Directory of Open Access Journals (Sweden)

    Novaković R.N.V.

    2003-01-01

    Full Text Available In this paper some results of numerical evaluation of transport coefficients in plasmas in the mixtures of argon and fluorine are presented. These transport characteristics are given in the function of the temperature for low pressures ranging from 0,1 kPa to 1,0 kPa and for low temperatures between 500 K and 5 000 K in argon plasmas with 20% and 30% of the fluorine added. It is assumed that the system is kept under constant pressure and that a corresponding state of local thermodynamical equilibrium (LTE is attained in it. The equilibrium plasma composition, necessary for the evaluations, was determined on the ground of the Saha equations for ionization processes and the law of mass action for the thermal dissociation of F2, combined with the charge conservation relation and the assumption that the pressure remained constant in the course of temperature variations. The ionization energy lowering, required in conjunction with the Saha equations, was obtained with the aid of a modified expression for the plasma Debye radius proposed previously. A previously derived expression for the modified Debye radius, offering the possibility to treat the plasmas considered as weakly non-ideal in the whole temperature range, is used. The cut-off at the Landau length rather than of the smallest of ionic radii is introduced. This alteration in the evaluation procedure brings different considerable changes in the final numerical results for the all relevant quantities.

  5. Local effects of ECRH on argon transport at ASDEX upgrade

    International Nuclear Information System (INIS)

    Future deuterium-tritium magnetically confined fusion power plants will most probably rely an high-Z Plasma Facing Components (PFCs) such as tungsten. This choice is determined by the necessity of low erosion of the first wall materials (to guarantee a long lifetime of the wall components) and by the need to avoid the too high tritium wall retention of typical carbon based PFCs. The experience gathered at the ASDEX Upgrade (AUG) tokamak has demonstrated the possibility of reliable and high performance plasma operation with a full tungsten-coated first wall. The observed accumulation of tungsten which can lead to excessive radiation losses is mitigated with the use of Electron Cyclotron Resonance Heating (ECRH). Although this impurity control method is routinely performed at AUG, the underlying physics principles are still not clear. This thesis aims an providing further knowledge an the effects of ECRH an the transport of impurities inside the core plasma. The transport of argon has been therefore investigated in-depth in purely ECR heated L-mode (low-confinement) discharges. Studies an impurity transport in centrally ECR heated nitrogen-seeded H-mode (high-confinement) discharges have also been performed. To this scope, a new crystal X-ray spectrometer of the Johann type has been installed an AUG for argon concentration and ion temperature measurements. New methods for the experimental determination of the total argon density through the integrated use of this diagnostic and of the Soft X-Ray (SXR) diode arrays have been developed. This gives the possibility of evaluating the full profiles of the argon transport coefficients from the linear flux-gradient dependency of local argon density. In comparison to classical χ2-minimization methods, the approach proposed here delivers transport coefficients intrinsically independent of the modelling of periodic relaxation mechanisms such as those Lied to sawtooth MHD (Magneto-Hydro-Dynamic) activity. Moreover, the good

  6. Inhibition of nitrite-induced toxicity in channel catfish by calcium chloride and sodium chloride

    Science.gov (United States)

    Tommasso J.R., Wright, M. I.; Simco, B.A.; Davis, K.B.

    1980-01-01

    Environmental chloride has been shown to inhibit methemoglobin formation in fish, thereby offering a protective effect against nitrite toxicity. Channel catfish (Ictalurus punctatus) were simultaneously exposed to various environmental nitrite and chloride levels (as either CaCl2 or NaCl) in dechlorinated tap water (40 mg/L total hardness, 47 mg/L alkalinity, 4 mg/L chloride, pH = 6.9-7.1, and temperature 21-24°C). Methemoglobin levels in fish simultaneously exposed to 2.5 mg/L nitrite and up to 30 mg/L chloride as either CaCl2 or NaCl were similar but significantly lower than in unprotected fish. Exposure to 10 mg/L nitrite and 60 mg/L chloride resulted in methemoglobin levels similar to those of the controls; most unprotected fish died. Fish exposed to 10 mg/L nitrite had significantly lower methemoglobin levels when protected with 15.0 mg/L chloride as CaCl2 than with NaCl. Fish exposed to nitrite in the presence of 60 mg/L chloride (as either CaCl2 or NaCl) had similar 24-h LC50 values that were significantly elevated above those obtained in the absence of chloride. Calcium had little effect on tolerance to nitrite toxicity in channel catfish in contrast to its large effect reported in steelhead trout (Salmo gairdneri).

  7. Amine and Titanium (IV Chloride, Boron (III Chloride or Zirconium (IV Chloride-Promoted Baylis-Hillman Reactions

    Directory of Open Access Journals (Sweden)

    Shi-Cong Cui

    2001-10-01

    Full Text Available The Baylis-Hillman reactions of various aryl aldehydes with methyl vinyl ketone at temperatures below -20oC using Lewis acids such as titanium (IV chloride, boron (III chloride or zirconium (IV chloride in the presence of a catalytic amount of selected amines used as a Lewis bases afford the chlorinated compounds 1 as the major product in very high yields. Acrylonitrile can also undergo the same reaction to give the corresponding chlorinated product in moderate yield. A plausible reaction mechanism is proposed. However, if the reaction was carried out at room temperature (ca. 20oC, then the Z-configuration of the elimination product 3, derived from 1, was formed as the major product.

  8. Failure analysis of primary argon storage tanks for fast breeder test reactor (FBTR) at Reactor Research Centre, Kalpakkam [Paper IIIA-e

    International Nuclear Information System (INIS)

    An attempt is made to bring out the details of the 'Failure Analysis' carried out on the four numbers of primary argon storage tanks made from AISI type 304L stainless steel for FBTR Project, after receipt at site. After inspection at site before erection, it was found that all the four tanks had suffered severe pitting and crevice corrosion on the inside surface. The study revealed that the corrosion from inside was caused by the presence of crevices formed due to weld spatters and excess or non-uniform penetration of weld beads along with the service water with a high chloride content, which had not been drained out fully, after the hydrostatic testing at the manufacture's shop. The water had remained in these tanks for about 12 months which caused the damage. Due to the severity of the corrosion attack, all the four tanks were rejected, new tanks were fabricated with modification suiting the requirement and since erected. (author)

  9. Hydrolysis of ferric chloride in solution

    International Nuclear Information System (INIS)

    The Detox trademark process uses concentrated ferric chloride and small amounts of catalysts to oxidize organic compounds. It is under consideration for oxidizing transuranic organic wastes. Although the solution is reused extensively, at some point it will reach the acceptable limit of radioactivity or maximum solubility of the radioisotopes. This solution could be cemented, but the volume would be increased substantially because of the poor compatibility of chlorides and cement. A process has been developed that recovers the chloride ions as HCl and either minimizes the volume of radioactive waste or permits recycling of the radioactive chlorides. The process involves a two-step hydrolysis at atmospheric pressure, or preferably under a slight vacuum, and relatively low temperature, about 200 degrees C. During the first step of the process, hydrolysis occurs according to the reaction below: FeCl3liquid + H2O → FeOClsolid + 2 HClgas During the second step, the hot, solid, iron oxychloride is sprayed with water or placed in contact with steam, and hydrolysis proceeds to the iron oxide according to the following reaction: 2 FeOClsolid + H2O → Fe2O3solid + 2 HClgas. The iron oxide, which contains radioisotopes, can then be disposed of by cementation or encapsulation. Alternately, these chlorides can be washed off of the solids and can then either be recycled or disposed of in some other way

  10. Chloride equilibrium potential in salamander cones

    Directory of Open Access Journals (Sweden)

    Bryson Eric J

    2004-12-01

    Full Text Available Abstract Background GABAergic inhibition and effects of intracellular chloride ions on calcium channel activity have been proposed to regulate neurotransmission from photoreceptors. To assess the impact of these and other chloride-dependent mechanisms on release from cones, the chloride equilibrium potential (ECl was determined in red-sensitive, large single cones from the tiger salamander retinal slice. Results Whole cell recordings were done using gramicidin perforated patch techniques to maintain endogenous Cl- levels. Membrane potentials were corrected for liquid junction potentials. Cone resting potentials were found to average -46 mV. To measure ECl, we applied long depolarizing steps to activate the calcium-activated chloride current (ICl(Ca and then determined the reversal potential for the current component that was inhibited by the Cl- channel blocker, niflumic acid. With this method, ECl was found to average -46 mV. In a complementary approach, we used a Cl-sensitive dye, MEQ, to measure the Cl- flux produced by depolarization with elevated concentrations of K+. The membrane potentials produced by the various high K+ solutions were measured in separate current clamp experiments. Consistent with electrophysiological experiments, MEQ fluorescence measurements indicated that ECl was below -36 mV. Conclusions The results of this study indicate that ECl is close to the dark resting potential. This will minimize the impact of chloride-dependent presynaptic mechanisms in cone terminals involving GABAa receptors, glutamate transporters and ICl(Ca.

  11. Study of electron recombination in liquid argon with the ICARUS TPC

    International Nuclear Information System (INIS)

    Electron recombination in liquid argon (LAr) is studied by means of charged particle tracks collected in various ICARUS liquid argon TPC prototypes. The dependence of the recombination on the particle stopping power has been fitted with a Birks functional dependence. The simulation of the process of electron recombination in Monte Carlo calculations is discussed. A quantitative comparison with previously published data is carried out

  12. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    International Nuclear Information System (INIS)

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images

  13. First measurement of the ionization yield of nuclear recoils in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, T. [Univ. of California, Berkeley, CA (United States). Dept. of Nuclear Engineering; Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Sangiorgio, Samuele [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Bernstein, A. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Foxe, Michael P. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Pennsylvania State Univ., University Park, PA (United States). Dept. of Mechanical and Nuclear Engineering; Hagmann, Chris [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Jovanovic, Igor [Pennsylvania State Univ., University Park, PA (United States). Dept. of Mechanical and Nuclear Engineering; Kazkaz, K. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Mozin, Vladimir V. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Norman, E. B. [Univ. of California, Berkeley, CA (United States). Dept. of Nuclear Engineering; Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Pereverzev, S. V. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Rebassoo, Finn O. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Sorensen, Peter F. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)

    2014-05-01

    Liquid phase argon has long been used as a target medium for particle detection via scintillation light. Recently there has been considerable interest in direct detection of both hypothetical darkmatter particles and coherent elastic neutrino nucleus scattering. These as-yet unobserved neutral particle interactions are expected to result in a recoiling argon atom O(keV), generally referred to in the literature as a nuclear recoil. This prompts the question of the available electromagnetic signal in a liquid argon detector. In this Letter we report the first measurement of the ionization yield (Qy), detected electrons per unit energy, resulting from nuclear recoils in liquid argon, measured at 6.7 keV. This is also the lowest energy measurement of nuclear recoils in liquid argon.

  14. Effect of argon addition on plasma parameters and dust charging in hydrogen plasma

    International Nuclear Information System (INIS)

    Experimental results on effect of adding argon gas to hydrogen plasma in a multi-cusp dusty plasma device are reported. Addition of argon modifies plasma density, electron temperature, degree of hydrogen dissociation, dust current as well as dust charge. From the dust charging profile, it is observed that the dust current and dust charge decrease significantly up to 40% addition of argon flow rate in hydrogen plasma. But beyond 40% of argon flow rate, the changes in dust current and dust charge are insignificant. Results show that the addition of argon to hydrogen plasma in a dusty plasma device can be used as a tool to control the dust charging in a low pressure dusty plasma.

  15. Characteristics of atmospheric-pressure, radio-frequency glow discharges operated with argon added ethanol

    Science.gov (United States)

    Sun, Wen-Ting; Li, Guo; Li, He-Ping; Bao, Cheng-Yu; Wang, Hua-Bo; Zeng, Shi; Gao, Xing; Luo, Hui-Ying

    2007-06-01

    Rf, atmospheric-pressure glow discharge (APGD) plasmas with bare metal electrodes have promising prospects in the fields of plasma-aided etching, thin film deposition, disinfection and sterilization, etc. In this paper, the discharge characteristics are presented for the rf APGD plasmas generated with pure argon or argon-ethanol mixture as the plasma-forming gas and using water-cooled, bare copper electrodes. The experimental results show that the breakdown voltage can be reduced significantly when a small amount of ethanol is added into argon, probably due to the fact that the Penning ionization process is involved, and a pure α-mode discharge can be produced more easily with the help of ethanol. The uniformity of the rf APGDs of pure argon or argon-ethanol mixtures using bare metallic electrodes is identified with the aid of the intensified charge coupled device images.

  16. First measurements with ARGONTUBE, a 5 m long drift Liquid Argon TPC

    International Nuclear Information System (INIS)

    The Liquid Argon Time Projection Chamber (LAr TPC) technique is a promising technology for future neutrino detectors. At LHEP of the University of Bern (Switzerland), an R and D program towards large detectors are on-going. The main goal is to show the feasibility of long drift paths over many meters. Therefore, a liquid Argon TPC with 5 m of drift distance was constructed. Many other aspects of the liquid Argon TPC technology are also investigated, such as a new device to generate high voltage in liquid Argon (Greinacher circuit), a recirculation filtering system and the multi-photon ionization of liquid Argon with a UV laser. Two detectors are built: a medium size prototype for specific detector technology studies, and ARGONTUBE, a 5 m long device

  17. Influence of longitudinal argon flow on DC glow discharge at atmospheric pressure

    Science.gov (United States)

    Zhu, Sha; Jiang, Weiman; Tang, Jie; Xu, Yonggang; Wang, Yishan; Zhao, Wei; Duan, Yixiang

    2016-05-01

    A one-dimensional self-consistent fluid model was employed to investigate the influence of longitudinal argon flow on the DC glow discharge at atmospheric pressure. It is found that the charges exhibit distinct dynamic behaviors at different argon flow velocities, accompanied by a considerable change in the discharge structure. The positive argon flow allows for the reduction of charge densities in the positive column and negative glow regions, and even leads to the disappearance of negative glow. The negative argon flow gives rise to the enhancement of charge densities in the positive column and negative glow regions. These observations are attributed to the fact that the gas flow convection influences the transport of charges through different manners by comparing the argon flow velocity with the ion drift velocity. The findings are important for improving the chemical activity and work efficiency of the plasma source by controlling the gas flow in practical applications.

  18. Combining sulfate electrowinning with chloride leaching

    Science.gov (United States)

    Fletcher, A. W.; Sudderth, R. B.; Olafson, S. M.

    1991-08-01

    Although the chloride leaching of copper sulfide concentrates has proved highly efficient, electrowinning from chloride solutions presents many difficulties, notably in cell design and the handling of the powder product. Sulfate electrowinning,on the other hand, continues to improve and has played a significant part in the widespread adoption of the solvent extraction-electrowinning process for copper recovery from low-grade ores. It has been found that the two steps can be combined by introducing a novel solvent extraction process after chloride leaching. This article presents the results of laboratory tests to prove the feasibility of this approach and discusses how it can be integrated into a commercially viable flow sheet.

  19. Electron Neutrino Classification in Liquid Argon Time Projection Chamber Detector

    CERN Document Server

    Płoński, Piotr; Sulej, Robert; Zaremba, Krzysztof

    2015-01-01

    Neutrinos are one of the least known elementary particles. The detection of neutrinos is an extremely difficult task since they are affected only by weak sub-atomic force or gravity. Therefore large detectors are constructed to reveal neutrino's properties. Among them the Liquid Argon Time Projection Chamber (LAr-TPC) detectors provide excellent imaging and particle identification ability for studying neutrinos. The computerized methods for automatic reconstruction and identification of particles are needed to fully exploit the potential of the LAr-TPC technique. Herein, the novel method for electron neutrino classification is presented. The method constructs a feature descriptor from images of observed event. It characterizes the signal distribution propagated from vertex of interest, where the particle interacts with the detector medium. The classifier is learned with a constructed feature descriptor to decide whether the images represent the electron neutrino or cascade produced by photons. The proposed ap...

  20. Image Segmentation in Liquid Argon Time Projection Chamber Detector

    CERN Document Server

    Płoński, Piotr; Sulej, Robert; Zaremba, Krzysztof

    2015-01-01

    The Liquid Argon Time Projection Chamber (LAr-TPC) detectors provide excellent imaging and particle identification ability for studying neutrinos. An efficient and automatic reconstruction procedures are required to exploit potential of this imaging technology. Herein, a novel method for segmentation of images from LAr-TPC detectors is presented. The proposed approach computes a feature descriptor for each pixel in the image, which characterizes amplitude distribution in pixel and its neighbourhood. The supervised classifier is employed to distinguish between pixels representing particle's track and noise. The classifier is trained and evaluated on the hand-labeled dataset. The proposed approach can be a preprocessing step for reconstructing algorithms working directly on detector images.

  1. A Thermodynamic Model for Argon Plasma Kernel Formation

    Directory of Open Access Journals (Sweden)

    James Keck

    2010-11-01

    Full Text Available Plasma kernel formation of argon is studied experimentally and theoretically. The experiments have been performed in a constant volume cylindrical vessel located in a shadowgraph system. The experiments have been done in constant pressure. The energy of plasma is supplied by an ignition system through two electrodes located in the vessel. The experiments have been done with two different spark energies to study the effect of input energy on kernel growth and its properties. A thermodynamic model employing mass and energy balance was developed to predict the experimental data. The agreement between experiments and model prediction is very good. The effect of various parameters such as initial temperature, initial radius of the kernel, and the radiation energy loss have been investigated and it has been concluded that initial condition is very important on formation and expansion of the kernel.

  2. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    Science.gov (United States)

    Efthymiopoulos, Ilias

    2001-04-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs.

  3. Fluorescence Spectrum of SiO in an Argon Matrix

    Science.gov (United States)

    Scullman, R.; Hormes, J.; Schroeder, W.; Wiggenhauser, H.

    1987-04-01

    Fluorescence from SiO matrix isolated in argon has been investigated in the wavelength region 120-300 nm. Fluorescence emission spectra from the valence states, A1Π, E1Σ+ and G1Π, revealed that nearly all radiation comes from one channel at 305 nm, which was analysed as originating from the b3Π-X1Σ+ transition. Contrary to the A1Π and G1Π states, the E1Σ+ state also decays radiatively, although weakly, through two other channels situated in the vicinity of 305 nm. These two channels were believed to originate from the a3Σ+-X1Σ+ and e3Σ--X1Σ+ transitions.

  4. The ATLAS liquid Argon calorimeters read-out system

    CERN Document Server

    Blondel, A; Fayard, L; La Marra, D; Léger, A; Matricon, P; Perrot, G; Poggioli, L; Prast, J; Riu, I; Simion, S

    2004-01-01

    The calorimetry of the ATLAS experiment takes advantage of different detectors based on the liquid Argon (LAr) technology. Signals from the LAr calorimeters are processed by various stages before being delivered to the Data Acquisition system. The calorimeter cell signals are received by the front-end boards, which digitize a predetermined number of samples of the bipolar waveform and sends them to the Read-Out Driver (ROD) boards. The ROD board receives triggered data from 1028 calorimeter cells, and determines the precise energy and timing of the signals by processing the discrete samplings of the pulse. In addition, it formats the digital stream for the following elements of the DAQ chain, and performs monitoring. The architecture and functionality of the ATLAS LAr ROD board are discussed, along with the final design of the Processing Unit boards housing the Digital Signal Processors (DSP). (9 refs).

  5. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    CERN Document Server

    Efthymiopoulos, I

    2001-01-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs. (3 refs).

  6. Photodegradation Mechanisms of Tetraphenyl Butadiene Coatings for Liquid Argon Detectors

    CERN Document Server

    Jones, B J P; Conrad, J M; Pla-Dalmau, A

    2013-01-01

    We report on studies of degradation mechanisms of tetraphenyl butadiene (TPB) coatings of the type used in neutrino and dark matter liquid argon experiments. Using gas chromatography coupled to mass spectrometry we have detected the ultraviolet-blocking impurity benzophenone (BP). We monitored the drop in performance and increase of benzophenone concentration in TPB plates with exposure to ultraviolet (UV) light, and demonstrate the correlation between these two variables. Based on the presence and initially exponential increase in the concentration of benzophenone observed, we propose that TPB degradation is a free radical-mediated photooxidation reaction, which is subsequently confirmed by displaying delayed degradation using a free radical inhibitor. Finally we show that the performance of wavelength-shifting coatings of the type envisioned for the LBNE experiment can be improved by 10-20%, with significantly delayed UV degradation, by using a 20% admixture of 4-tert-Butylcatechol.

  7. Photodegradation mechanisms of tetraphenyl butadiene coatings for liquid argon detectors

    Science.gov (United States)

    Jones, B. J. P.; VanGemert, J. K.; Conrad, J. M.; Pla-Dalmau, A.

    2013-01-01

    We report on studies of degradation mechanisms of tetraphenyl butadiene (TPB) coatings of the type used in neutrino and dark matter liquid argon experiments. Using gas chromatography coupled to mass spectrometry we have detected the ultraviolet-blocking impurity benzophenone. We monitored the drop in performance and increase of benzophenone concentration in TPB plates with exposure to ultraviolet (UV) light, and demonstrate the correlation between these two variables. Based on the presence and initially exponential increase in the concentration of benzophenone observed, we propose that TPB degradation is a free radical-mediated photooxidation reaction, which is subsequently confirmed by displaying delayed degradation using a free radical inhibitor. Finally we show that the performance of wavelength-shifting coatings of the type envisioned for the LBNE experiment can be improved by 10-20%, with significantly delayed UV degradation, by using a 20% admixture of 4-tert-Butylcatechol.

  8. Liquid Argon Cryogenic Detector Calibration by Inelastic Scattering of Neutrons

    CERN Document Server

    Polosatkin, Sergey; Dolgov, Alexander

    2014-01-01

    A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron generator. Features of kinematics of inelastic scattering cause sufficient (forty times) increase in count rate of useful events relative to traditional scheme exploited elastic scattering with the same recoil energy and compatible energy resolution. The benefits of the proposed scheme of calibration most well implemented with the use of tagged neutron generator as a neutron source that allows to eliminate background originated from casual coincidence of signals on cryogenic detector and additional detector of scattered neutrons.

  9. Characterization of SF6/Argon Plasmas for Microelectronics Applications; TOPICAL

    International Nuclear Information System (INIS)

    This report documents measurements in inductively driven plasmas containing SF(sub 6)/Argon gas mixtures. The data in this report is presented in a series of appendices with a minimum of interpretation. During the course of this work we investigated: the electron and negative ion density using microwave interferometry and laser photodetachment; the optical emission; plasma species using mass spectrometry, and the ion energy distributions at the surface of the rf biased electrode in several configurations. The goal of this work was to assemble a consistent set of data to understand the important chemical mechanisms in SF(sub 6) based processing of materials and to validate models of the gas and surface processes

  10. Argon luminescence bands between 1600 A and 2900 A

    International Nuclear Information System (INIS)

    It is proposed that the luminescence bands observed in high pressure argon between 1600A and 2900A are due to transitions involving excited states, Ar2+, of the molecular ion, Ar2+: the initial state is a bound state having a 2S-2S0 ion-atom asymptote and the final states two of the first set of molecular ion states which dissociate to the ion-atom pair 2P-1S0. This assumption accounts for most known experimental data on this emission bands. The competition between the radiative transitions and the quenching collisions between the excited-ions and electrons in α particle tracks has been studied experimentally and is discussed in terms of the present hypothesis. A comparison is also made between the neutralisation of excited and ground state molecular ions

  11. Low energy scattering in an argon and methane system

    International Nuclear Information System (INIS)

    The theory for an argon-methane scattering system and several calculations in both the close coupling and coupled states schemes are presented. The problem is reduced to the irreducible A, E, and T representations and calculations in all these symmetries are performed and combined. Methane is treated as a rigid rotor. Two interaction potentials are employed and both contain an angle dependent term. Compound state resonances in this system are studied extensively and characterized. Close coupling and coupled states cross sections are compared in calculations with both interaction potentials and in the A and E representations. Coupled states cross sections in all three representations are presented over a range of energies from 25 to 90 MeV

  12. Nanotextured Shrink Wrap Superhydrophobic Surfaces by Argon Plasma Etching

    Directory of Open Access Journals (Sweden)

    Jolie M. Nokes

    2016-03-01

    Full Text Available We present a rapid, simple, and scalable approach to achieve superhydrophobic (SH substrates directly in commodity shrink wrap film utilizing Argon (Ar plasma. Ar plasma treatment creates a stiff skin layer on the surface of the shrink film. When the film shrinks, the mismatch in stiffness between the stiff skin layer and bulk shrink film causes the formation of multiscale hierarchical wrinkles with nano-textured features. Scanning electron microscopy (SEM images confirm the presence of these biomimetic structures. Contact angle (CA and contact angle hysteresis (CAH measurements, respectively, defined as values greater than 150° and less than 10°, verified the SH nature of the substrates. Furthermore, we demonstrate the ability to reliably pattern hydrophilic regions onto the SH substrates, allowing precise capture and detection of proteins in urine. Finally, we achieved self-driven microfluidics via patterning contrasting superhydrophilic microchannels on the SH Ar substrates to induce flow for biosensing.

  13. Attosecond Coherent Control of Single and Double Photoionization in Argon.

    Science.gov (United States)

    Hogle, C W; Tong, X M; Martin, L; Murnane, M M; Kapteyn, H C; Ranitovic, P

    2015-10-23

    Ultrafast high harmonic beams provide new opportunities for coherently controlling excitation and ionization processes in atoms, molecules, and materials on attosecond time scales by employing multiphoton two-pathway electron-wave-packet quantum interferences. Here we use spectrally tailored and frequency tuned vacuum and extreme ultraviolet harmonic combs, together with two phase-locked infrared laser fields, to show how the total single and double photoionization yields of argon can be coherently modulated by controlling the relative phases of both optical and electronic-wave-packet quantum interferences. This Letter is the first to apply quantum control techniques to double photoionization, which is a fundamental process where a single, high-energy photon ionizes two electrons simultaneously from an atom. PMID:26551112

  14. Dynamic resonances and tunnelling in the multiphoton ionization of argon

    International Nuclear Information System (INIS)

    We present results of wavepacket simulations for multiphoton ionization in argon. A single active electron model is applied to estimate the single-electron ionization rates and photoelectron energy distributions for λ = 390 nm light with intensities up to I = 2 x 1014 W cm-2. The multiphoton ionization rates are compared with R-matrix Floquet calculations and found to be in very good agreement. The photoelectron energy distribution is used to study the nature of ionization at the higher intensities. Our results are consistent with recent calculations and experiments which show the imprint of the tunnelling process in the multiphoton regime. For few-cycle intense pulses, we find that the strong modulation of intensity and increased bandwidth leads to dynamic mixing of the 3d and 5s resonances.

  15. The liquid argon TPC for the ICARUS experiment

    CERN Document Server

    Arneodo, F

    1997-01-01

    The ICARUS project aims at the realisation of a large liquid argon TPC to be run at the Underground Laboratories of Gran Sasso in Italy. An intense R&D; activity has put on firm grounds this new detector technology and experimentally confirmed its feasibility on a few ton scale. Based on these solid achievements, the collaboration is now confident of being able to build and safely operate a multi-kton detector. The reseach program of the experiment involves the systematic study of a wide spectrum of physical phenomena covering many orders of magnitude in the energy deposited in the detector: from the few MeV of solar neutrino interactions, to the about one GeV of the proton decay and atmospheric neutrinos, up to the higher energies of neutrinos from accelerators.

  16. Large area liquid argon detectors for interrogation systems

    International Nuclear Information System (INIS)

    Measurements of the efficiency, pulse shape, and energy and time resolution of liquid argon (LAr) detectors are presented. Liquefied noble gas-based (LNbG) detectors have been developed for the detection of dark matter and neutrinoless double-beta decay. However, the same qualities that make LNbG detectors ideal for these applications, namely their size, cost, efficiency, pulse shape discrimination and resolution, make them promising for portal screening and the detection of Special Nuclear Materials (SNM). Two 18-liter prototype detectors were designed, fabricated, and tested, one with pure LAr and the other doped with liquid Xe (LArXe). The LArXe detector presented the better time and energy resolution of 3.3 ns and 20% at 662 KeV, respectively. The total efficiency of the detector was measured to be 35% with 4.5% of the total photons detected in the photopeak.

  17. Response Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter

    CERN Document Server

    Aharrouche, M; Di Ciaccio, L; El Kacimi, M; Gaumer, O; Gouanère, M; Goujdami, D; Lafaye, R; Laplace, S; Le Maner, C; Neukermans, L; Perrodo, P; Poggioli, L; Prieur, D; Przysiezniak, H; Sauvage, G; Wingerter-Seez, I; Zitoun, R; Lanni, F; Lü, L; Ma, H; Rajagopalan, S; Takai, H; Belymam, A; Benchekroun, D; Hakimi, M; Hoummada, A; Gao, Y; Stroynowsk, R; Aleksa, M; Carli, T; Fassnacht, P; Gianotti, F; Hervás, L; Lampl, W; Collot, J; Hostachy, J Y; Ledroit-Guillon, F; Malek, F; Martin, P; Viret, S; Leltchouk, M; Parsons, J A; Simion, S; Barreiro, F; Del Peso, J; Labarga, L; Oliver, C; Rodier, S; Barrillon, P; Benchouk, C; Djama, F; Hubaut, F; Monnier, E; Pralavorio, P; Sauvage, D; Serfon, C; Tisserant, S; Tóth, J; Banfi, D; Carminati, L; Cavalli, D; Costa, G; Delmastro, M; Fanti, M; Mandell, L; Mazzanti, M; Tartarelli, F; Kotov, K; Maslennikov, A; Pospelov, G; Tikhonov, Yu; Bourdarios, C; Fayard, L; Fournier, D; Iconomidou-Fayard, L; Kado, M; Parrour, G; Puzo, P; Rousseau, D; Sacco, R; Serin, L; Unal, G; Zerwas, D; Dekhissi, B; Derkaoui, J; EL Kharrim, A; Maaroufi, F; Cleland, W; Lacour, D; Laforge, B; Nikolic-Audit, I; Schwemling, Ph; Ghazlane, H; Cherkaoui El Moursli, R; Idrissi Fakhr-Eddine, A; Boonekamp, M; Kerschen, N; Mansoulié, B; Meyer, P; Schwindlingy, J; Lund-Jensen, B

    2007-01-01

    The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.

  18. Kinetic modeling of the Townsend breakdown in argon

    Energy Technology Data Exchange (ETDEWEB)

    Macheret, S. O.; Shneider, M. N. [Department of Mechanical and Aerospace Engineering, Princeton University, D-414 Engineering Quadrangle, Princeton, New Jersey 08544 (United States)

    2013-10-15

    Kinetic modeling of the Townsend breakdown in argon was performed in the “forward-back” approximation. The kinetic model was found to adequately describe the left branch of the Paschen curve, and the important role of ionization by fast ions and atoms near the cathode, as well as the increase in secondary emission coefficient in strong electric fields described in the literature, was confirmed. The modeling also showed that the electron energy distribution function develops a beam of high-energy electrons and that the runaway effect, i.e., the monotonic increase of the mean electron energy with the distance from the cathode, occurs at the left branch of the Paschen curve.

  19. Pulsed electron beam propagation in argon and nitrogen gas mixture

    International Nuclear Information System (INIS)

    The paper presents the results of current measurements for the electron beam, propagating inside a drift tube filled in with a gas mixture (Ar and N2). The experiments were performed using the TEA-500 pulsed electron accelerator. The main characteristics of electron beam were as follows: 60 ns pulse duration, up to 200 J energy, and 5 cm diameter. The electron beam propagated inside the drift tube assembled of three sections. Gas pressures inside the drift tube were 760 ± 3, 300 ± 3, and 50 ± 1 Torr. The studies were performed in argon, nitrogen, and their mixtures of 33%, 50%, and 66% volume concentrations, respectively

  20. Low-energy ion implantation: Large mass fractionation of argon

    Science.gov (United States)

    Ponganis, K. V.; Graf, TH.; Marti, K.

    1993-01-01

    The isotropic signatures of noble gases in the atmospheres of the Earth and other planets are considerably evolved when compared to signatures observed in the solar wind. The mechanisms driving the evolution of planetary volatiles from original compositions in the solar accretion disk are currently poorly understood. Modeling of noble-gas compositional histories requires knowledge of fractionating processes that may have operated through the evolutionary stages. Since these gases are chemically inert, information on noble-gas fractionation processes can be used as probes. The importance of understanding these processes extends well beyond 'noble-gas planetology.' Trapped argon acquired by low-energy implantation (approximately less than 100 eV) into solids is strongly mass fractionated (approximately greater than or equal to 3 percent/amu). This has potential implications for the origin and evolution of terrestrial planet atmospheres.

  1. Primary argon laser trabeculoplasty in the treatment of glaucoma

    International Nuclear Information System (INIS)

    During the last ten years, argon laser trabeculoplasty has been shown to be a very useful tool in the treatment of glaucoma when medical therapy has failed. In the present study laser was used as primary therapy in 27 patients with newly detected glaucoma. Pretreatment with topical timolol gave an immediate pressure drop in all eyes, and the dreaded actue pressure rise after laser treatment was avoided. Upon follow-up examination after two years, more than half the patients had an intraocular pressure below 21 mm Hg without additional therapy. Primary laser trabeculoplasty was found to be a safe and time-saving procedure. Expenses and complications associated with medical therapy are reduced. Many patients may avoid lifelong daily instillation of eye drops. 11 refs., 2 tabs

  2. Development of membrane cryostats for large liquid argon neutrino detectors

    CERN Document Server

    Montanari, D; Gendotti, A; Geynisman, M; Hentschel, S; Loew, T; Mladenov, D; Montanari, C; Murphy, S; Nessi, M; Norris, B; Noto, F; Rubbia, A; Sharma, R; Smargianaki, D; Stewart, J; Vignoli, C; Wilson, P; Wu, S

    2015-01-01

    A new collaboration is being formed to develop a multi-kiloton Long-Baseline neutrino experiment that will be located at the Surf Underground Research Facility (SURF) in Lead, SD. In the present design, the detector will be located inside cryostats filled with 68,400 ton of ultrapure liquid argon (less than 100 parts per trillion of oxygen equivalent contamination). To qualify the membrane technology for future very large-scale and underground implementations, a strong prototyping effort is ongoing: several smaller detectors of growing size with associated cryostats and cryogenic systems will be designed and built at Fermilab and CERN. They will take physics data and test different detector elements, filtration systems, design options and installation procedures. In addition, a 35 ton prototype is already operational at Fermilab and will take data with single-phase detector in early 2016. After the prototyping phase, the multi-kton detector will be constructed. After commissioning, it will detect and study ne...

  3. Electron-ion recombination study in argon at atmospheric pressure

    International Nuclear Information System (INIS)

    This study deals with a wall-stabilized arc burning in argon at atmospheric pressure. A transient mode is obtained using a fast thyristor connected to the electrodes, which short-circuits the discharge. By means of two wavelengths laser interferometry and spectroscopy measurements we have determined the temporal changes of the electron density, ground state atom density and excited atom density. We have shown that, when the electric field is suppressed, the electron temperature rapidly decreases to the gas temperature before changing electron and atom densities. This phenomenon is applied to determine the gas temperature and to evaluate the role played by ionization in electron density balance. The coefficients of ambipolar diffusion, ionization and recombination and an apparent recombination coefficient are determined versus electron temperature and compared with theoretical values

  4. Grid pattern Argon Laser photocoagulation for diabetic diffuse macular edema

    Directory of Open Access Journals (Sweden)

    Karkhane R

    1998-05-01

    Full Text Available Purpose: to determine the effect of Grid pattern laser photocoagulation on diabetic diffuse macular edema with assessment of visual outcome. Patients & Methods: The author reviewed the medical records of 84 eyes of 62 patients with diabetic diffuse macular edema treated with Grid pattern green Argon laser photocoagulation in Farabi Eye Hospital between the years 1992-1995, the follow-up period was 16-48 months (average 24.55±6.42, median 28 mounths. Results: Visual acuity was improved in 11.9%; unchanged in 65.4% and worsened in 22.7% of eyes. Conclusion: In assessing long-term visual outcome, Grid laser photocoagulation is an effective modality in maintaining or improving visual acuity.

  5. Photodegradation mechanisms of tetraphenyl butadiene coatings for liquid argon detectors

    International Nuclear Information System (INIS)

    We report on studies of degradation mechanisms of tetraphenyl butadiene (TPB) coatings of the type used in neutrino and dark matter liquid argon experiments. Using gas chromatography coupled to mass spectrometry we have detected the ultraviolet-blocking impurity benzophenone. We monitored the drop in performance and increase of benzophenone concentration in TPB plates with exposure to ultraviolet (UV) light, and demonstrate the correlation between these two variables. Based on the presence and initially exponential increase in the concentration of benzophenone observed, we propose that TPB degradation is a free radical-mediated photooxidation reaction, which is subsequently confirmed by displaying delayed degradation using a free radical inhibitor. Finally we show that the performance of wavelength-shifting coatings of the type envisioned for the LBNE experiment can be improved by 10-20%, with significantly delayed UV degradation, by using a 20% admixture of 4-tert-Butylcatechol.

  6. Alkali metal and ammonium chlorides in water and heavy water (binary systems)

    CERN Document Server

    Cohen-Adad, R

    1991-01-01

    This volume surveys the data available in the literature for solid-fluid solubility equilibria plus selected solid-liquid-vapour equilibria, for binary systems containing alkali and ammonium chlorides in water or heavy water. Solubilities covered are lithium chloride, sodium chloride, potassium chloride, rubidium chloride, caesium chloride and ammonium chloride in water and heavy water.

  7. Hydrogenation of Tasmanian alginite in the presence of tin (II) chloride and zinc chloride

    Energy Technology Data Exchange (ETDEWEB)

    Russell, N.J.

    1981-10-01

    A Mersey River (Tasmanian) algnite concentrate was heated (3 Cmin$SUP$-$SUP$1 to temperatures of 200-480 C in a small capacity, high-pressure, single-cell differential thermal analysis, batch autoclave under nitrogen or hydrogen (initial pressure 9.8 MPa) with or without 10 wt% zinc chloride or tin (II) chloride. An organic solvent (vehicle) was not used in these experiments. Although there is an almost complete conversion of alginite to gaseous and liquid products between 425 and 450 C, the compositions of the autoclave gas samples, the yields and compositions of the hexane-soluble material derived from the autoclave products, and the optical properties of the hexane-soluble residues, reflect the experimental conditions, in particular the influence of the metal chlorides. Principal phases of hydrogen uptake by alginite occur at different temperatures in a hydrogen atmosphere depending on the presence and nature of the metal chloride. The autoclave gas compositions reveal a clear distinction between the uncatalysed and catalysed experiments. The hydrocarbon gas ratios permit a distinction to be made between catalytic (carbonium ion mechanism) reactions and thermal (free radical mechanism) reactions; at higher temperatures the latter are dominant, even in the catalysed experiments. The metal chlorides lower the organic sulphur and nitrogen contents of the hexane-soluble material; zinc chloride being more effective than tin (II) chloride. Incident light fluorescence microscopy suggests that zinc chloride and tin (II) chloride give rise to different hydrogenation reactions between 300 and 425 C. Incident light fluorescence microscopy is a most useful method of studying the petrography of alignite in the hexane-insoluble residues. (28 refs.)

  8. Atmospheric dispersion of argon-41 from anuclear research reactor: measurement and modeling of plume geometry and gamma radiation field

    DEFF Research Database (Denmark)

    Lauritzen, Bent; Astrup, Poul; Drews, Martin; Jørgensen, Hans; Mikkelsen, Torben; Thykier-Nielsen, Søren; Aage, Helle Karina; Korsbech, Uffe C C; Bargholz, Kim; Rojas-Palma, Carlos; Van Ammel, Raf

    2003-01-01

    An atmospheric dispersion experiment was conducted using a visible tracer along with the routine release of argon-41 from the BR1 research reactor in Mol, Belgium. Simultaneous measurements of plume geometry and radiation fields for argon-41 decay were performed as well as measurements of the argon...

  9. Method for preparation of melts of alkali metal chlorides with highly volatile polyvalent metal chlorides

    International Nuclear Information System (INIS)

    A method for production of alkali metal (Cs, Rb, K) chloride melts with highly volatile polyvalent metal chlorides is suggested. The method consists, in saturation of alkali metal chlorides, preheated to the melting point, by volatile component vapours (titanium tetrachloride, molybdenum or tantalum pentachloride) in proportion, corresponding to the composition reguired. The saturation is realized in an evacuated vessel with two heating areas for 1-1.5 h. After gradual levelling of temperature in both areas the product is rapidly cooled. 1 fig.; 1 tab

  10. Determination of the number densities of argon metastables in argon-hydrogen plasma by absorption and self-absorption methods

    Energy Technology Data Exchange (ETDEWEB)

    Gavare, Z [Institute of Atomic Physics and Spectroscopy, University of Latvia, Skunu str. 4, Riga LV -1050 (Latvia); Goett, D [Institute for Low Temperature Plasma Physics, 17489 Greifswald (Germany); Pipa, A V [Institute for Low Temperature Plasma Physics, 17489 Greifswald (Germany); Roepcke, J [Institute for Low Temperature Plasma Physics, 17489 Greifswald (Germany); Skudra, A [Institute of Atomic Physics and Spectroscopy, University of Latvia, Skunu str. 4, Riga LV -1050 (Latvia)

    2006-08-15

    The number densities of Ar 3s{sup 2}3p{sup 5}4s levels have been measured by means of two methods: a self-absorption method with a mirror behind the discharge vessel and an absorption method with a high-frequency electrodeless discharge lamp. Concentrations ranging from 6 x 10{sup 7}-4 x 10{sup 9} cm{sup -3} were obtained for the Ar 3s{sup 2}3p{sup 5}4s levels, depending on the argon content (10-100% Ar) in Ar/H{sub 2} microwave plasma. The populations of various sublevels of measured resonant and metastable states coincide within the experimental errors. It was observed that values from measurements of both methods are in good agreement.

  11. Oral cadmium chloride intoxication in mice

    DEFF Research Database (Denmark)

    Andersen, O; Nielsen, J B; Svendsen, P

    1988-01-01

    Diethyldithiocarbamate (DDC) is known to alleviate acute toxicity due to injection of cadmium salts. However, when cadmium chloride was administered by the oral route, DDC enhanced rather than alleviated the acute toxicity; both oral and intraperitoneal (i.p.) administration of DDC had this effec...

  12. Liquid crystalline critical dynamics in decylammonium chloride

    CERN Document Server

    Lee, K W; Lee, C E; Kang, K H; Rhee, C; Kang, J K

    1999-01-01

    Collective chain dynamics and phase transitions in a model biomembrane, decylammonium chloride (C sub 1 sub 0 H sub 2 sub 1 NH sub 3 Cl), were studied by means of proton nuclear magnetic resonance. Our measurements sensitively reflect the critical dynamics associated with the smectic C to smectic A transition of the lipid bilayer.

  13. Liquid crystalline critical dynamics in decylammonium chloride

    International Nuclear Information System (INIS)

    Collective chain dynamics and phase transitions in a model biomembrane, decylammonium chloride (C10H21NH3Cl), were studied by means of proton nuclear magnetic resonance. Our measurements sensitively reflect the critical dynamics associated with the smectic C to smectic A transition of the lipid bilayer

  14. Chloride diffusion in partially saturated cementitious material

    DEFF Research Database (Denmark)

    Nielsen, Erik Pram; Geiker, Mette Rica

    2003-01-01

    The paper proposes a combined application of composite theory and Powers' model for microstructural development for the estimation of the diffusion coefficient as a function of the moisture content of a defect-free cementitious material. Measurements of chloride diffusion in mortar samples (440 kg...

  15. 75 FR 19657 - Barium Chloride From China

    Science.gov (United States)

    2010-04-15

    ... Commission found that the domestic interested party group response to its notice of institution (74 FR 31757... COMMISSION Barium Chloride From China AGENCY: United States International Trade Commission. ACTION: Notice of Commission determination to conduct a full five-year review concerning the antidumping duty order on...

  16. 75 FR 20625 - Barium Chloride From China

    Science.gov (United States)

    2010-04-20

    ... established a schedule for the conduct of this review (74 FR 62587, November 30, 2010). Subsequently, counsel... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Barium Chloride From China AGENCY: United States International Trade Commission. ACTION:...

  17. Chloride concentration affects soil microbial community

    Czech Academy of Sciences Publication Activity Database

    Gryndler, Milan; Rohlenová, Jana; Kopecký, Jan; Matucha, Miroslav

    2008-01-01

    Roč. 71, č. 7 (2008), s. 1401-1408. ISSN 0045-6535 R&D Projects: GA ČR GA526/05/0636 Institutional research plan: CEZ:AV0Z50200510; CEZ:AV0Z50380511 Keywords : soil chloride * terminal restriction fragments * soil microorganisms Subject RIV: EE - Microbiology, Virology Impact factor: 3.054, year: 2008

  18. Determination of chloride in uranium solutions

    Energy Technology Data Exchange (ETDEWEB)

    Danse, A.; Stoch, H.; Steele, T.W.

    1967-05-15

    Thiocyanate is first removed by precipitation with a small excess of a copper solution, and the cations are removed by passing the filtrate through a cation-exchange resin. The chloride is determined in the eluate by a potentiometric titration in which silver nitrate solution is used.

  19. Amperometric Sensor for Detection of Chloride Ions

    Directory of Open Access Journals (Sweden)

    Rene Kizek

    2008-09-01

    Full Text Available Chloride ion sensing is important in many fields such as clinical diagnosis, environmental monitoring and industrial applications. We have measured chloride ions at a carbon paste electrode (CPE and at a CPE modified with solid AgNO3, a solution of AgNO3 and/or solid silver particles. Detection limits (3 S/N for chloride ions were 100 μM, 100 μM and 10 μM for solid AgNO3, solution of AgNO3 and/or solid silver particles, respectively. The CPE modified with silver particles is the most sensitive to the presence chloride ions. After that we approached to the miniaturization of the whole electrochemical instrument. Measurements were carried out on miniaturized instrument consisting of a potentiostat with dimensions 35 × 166 × 125 mm, screen printed electrodes, a peristaltic pump and a PC with control software. Under the most suitable experimental conditions (Britton-Robinson buffer, pH 1.8 and working electrode potential 550 mV we estimated the limit of detection (3 S/N as 500 nM.

  20. Polyvinyl chloride filled with bismuth oxychloride powder

    Czech Academy of Sciences Publication Activity Database

    Polášková, M.; Sedláček, T.; Kharlamov, Alexander; Pivokonský, Radek; Saha, P.

    Larnaca : Polymer Processing Society, 2009, s. 242. [Polymer Processing Society Europe/Africa Regional Meeting. Larnaca (GR), 18.10.2009-21.10.2009] Institutional research plan: CEZ:AV0Z20600510 Keywords : olyvinyl chloride * bismuth oxychloride * radiopaque agents Subject RIV: BK - Fluid Dynamics

  1. Regulated trafficking of the CFTR chloride channel

    NARCIS (Netherlands)

    Braakman, L.J.; Kleizen, B.; Jonge, H.R. de

    2000-01-01

    The cystic fibrosis transmembrane conductance regulator (CFTR), the ABC transporter encoded by the cystic fibrosis gene, is localized in the apical membrane of epithelial cells where it functions as a cyclic AMP-regulated chloride channel and as a regulator of other ion channels and transporters. Wh

  2. Binary nucleation of water and sodium chloride

    Czech Academy of Sciences Publication Activity Database

    Němec, Tomáš; Maršík, František; Palmer, A.

    2006-01-01

    Roč. 124, č. 4 (2006), 0445091-0445096. ISSN 0021-9606 R&D Projects: GA ČR(CZ) GA101/05/2536 Institutional research plan: CEZ:AV0Z20760514 Keywords : binary nucleation * sodium chloride * water Subject RIV: BJ - Thermodynamics Impact factor: 3.166, year: 2006

  3. 21 CFR 184.1446 - Manganese chloride.

    Science.gov (United States)

    2010-04-01

    ..., and crystallized. (b) The ingredient meets the specifications of the Food Chemicals Codex, 3d Ed... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Manganese chloride. 184.1446 Section 184.1446 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD...

  4. A dual type gridded ionization chamber as purity monitor of liquid argon

    International Nuclear Information System (INIS)

    The liquid argon time projection chamber (LATPC) is currently developed for detecting solar neutrons or proton decays. A dual type gripped ionization chamber with different drift distances of liberated electrons is constructed to measure the purity of liquid argon. A purification system of gaseous argon for LATPC with a drift space of about 150 cm is also constructed. The performances of both the dual type gripped ionization chamber and the purifier are tested seeking to develop a large scale LATPC. It is demonstrated that the attenuation length of electrons and also the impurity level in liquid argon can be well determined in the dual type gripped ionization chamber. In the case of the purifier, there still remains unknown low-level impurities in purified liquid argon. The results are compared with UCI data which were obtained with liquid argon mixed with water vapor. the same tendency is found in the attenuation length of their data as in the present results. This seems to suggest the dominant impurity remaining in the purifier is still water. The present apparatus was previously tested with liquid argon purified by other purification system of Ti-Ba getters. The attenuation length obtained by those tests was almost 100 cm. (N.K.)

  5. Hydrolysis of ferric chloride in solution

    Energy Technology Data Exchange (ETDEWEB)

    Lussiez, G.; Beckstead, L.

    1996-11-01

    The Detox{trademark} process uses concentrated ferric chloride and small amounts of catalysts to oxidize organic compounds. It is under consideration for oxidizing transuranic organic wastes. Although the solution is reused extensively, at some point it will reach the acceptable limit of radioactivity or maximum solubility of the radioisotopes. This solution could be cemented, but the volume would be increased substantially because of the poor compatibility of chlorides and cement. A process has been developed that recovers the chloride ions as HCl and either minimizes the volume of radioactive waste or permits recycling of the radioactive chlorides. The process involves a two-step hydrolysis at atmospheric pressure, or preferably under a slight vacuum, and relatively low temperature, about 200{degrees}C. During the first step of the process, hydrolysis occurs according to the reaction below: FeCl{sub 3 liquid} + H{sub 2}O {r_arrow} FeOCl{sub solid} + 2 HCl{sub gas} During the second step, the hot, solid, iron oxychloride is sprayed with water or placed in contact with steam, and hydrolysis proceeds to the iron oxide according to the following reaction: 2 FeOCl{sub solid} + H{sub 2}O {r_arrow} Fe{sub 2}O{sub 3 solid} + 2 HCl{sub gas}. The iron oxide, which contains radioisotopes, can then be disposed of by cementation or encapsulation. Alternately, these chlorides can be washed off of the solids and can then either be recycled or disposed of in some other way.

  6. Argon Kα measurement on DIII endash D by Ross filters technique (abstract)

    International Nuclear Information System (INIS)

    Techniques to reduce the heat flux to the divertor plates in tokamak power plants and the consequent erosion of, and subsequent damage to the divertor target plates include the injection of impurities such as argon, that can dissipate the energy (through radiative or collisional processes) before it reaches the target plates. An important issue with this type of scheme is poisoning of the plasma core by the impurities introduced in the divertor region. Subsequently, there is a desire to measure the profiles of the injected impurities in the core. X-ray Ross filters with an effective narrow band pass centered on the argon Kα line at 3.2 keV, have been installed on two of the existing x-ray arrays on DIII endash D in order to help determine the argon concentration profiles. Emissivity profiles of the Kα lines and the emissivity profiles for the argon enhanced continuum can be inferred from the inverted filtered x-ray brightness signals if Te, ne, and Ar18+ profiles are known. The MIST code is used to couple the filtered x-ray signals to the time dependent measurements of Te and ne. Further, the Ar16+ profiles measured by charge transfer spectroscopy, are used as a constraint on the MIST code runs to calculate Ar18+ profiles and unfold the argon emissivity profiles. A discussion of the Ross filters, the DIII endash D argon data, and the data analysis scheme for inferring argon emissivity profiles will be discussed. Estimates of the total argon concentration in the core determined from this technique in DIII endash D argon puff experiments will be presented. copyright 1999 American Institute of Physics

  7. Viscosity and density tables of sodium chloride solutions

    Energy Technology Data Exchange (ETDEWEB)

    Fair, J.A.; Ozbek, H. (comps.)

    1977-04-01

    A file is presented containing tabulated data extracted from the scientific literature on the density and viscosity of aqueous sodium chloride solutions. Also included is a bibliography of the properties of aqueous sodium chloride solutions. (MHR)

  8. Design Principles and Operational Results of the Cryogenic System for the ATLAS Liquid Argon Calorimeter

    CERN Document Server

    Fabre, C; Chalifour, M; Gonidec, G; Passardi, Giorgio; Petit, P; Pezzetti, M; Wicek, F

    2009-01-01

    The ATLAS liquid argon calorimeter housed in three independent cryostats containing a total argon volume of about 78 m3 has been installed in the underground cavern. The three detectors have been cooled down following stringent temperature gradient limits and have been filled with liquid argon. The cryostats are now in a stable condition for periods going up to almost two years. The temperature uniformity within each of the three detector volumes is found to be within 70 mK rms, while the temperature stability stays below 5 mK rms.

  9. Changes in a surface of polycrystalline aluminum upon bombardment with argon ions

    Science.gov (United States)

    Ashkhotov, O. G.; Ashkhotova, I. B.; Bliev, A. P.; Magkoev, T. T.; Krymshokalova, D. A.

    2014-10-01

    The interaction between argon ions and a natural oxide layer of polycrystalline aluminum is studied via Auger electron (AE) and electron energy loss (EEL) spectroscopy. It is found that bombardment with argon ions whose energy is lower than the Al2O3 sputtering threshold results in the accumulation of bombarding ions in interstitial surface voids, thus forming a supersaturated solid solution of target atoms and bombarding ions of argon and nitrogen entrapped by the ion beam from the residual gas of the working chamber of the spectrometer.

  10. Effect of secondary emission on the afterglow of argon with negatively charged dust particles

    International Nuclear Information System (INIS)

    A theoretical model for an argon/dusty plasma afterglow in presence of nano-sized dust particles with large density is developed. According to the model, in the plasma afterglow the electrons are generated in metastable collisions and in the secondary emission by collisions of ions with electrodes. By using the model and experimental time-dependencies for metastable density and electrode bias, the time-dependencies for electron density in argon/dusty plasma afterglow are calculated. The effect of secondary emission on electron generation in argon/dusty plasma afterglow is analyzed.

  11. The production of regular pyramids on argon ion bombarded surfaces of copper crystals

    International Nuclear Information System (INIS)

    Argon ion bombardment of poly-crystalline copper is shown to produce pyramid covered surfaces on grains having orientation in particular high index direction. Single crystals cut in similar direction also show pyramid covered surfaces when bombarded with 40 keV argon ions. Evidence is presented to show that the dominant parameter contributing to pyramid production is crystallographic, rather than impurity-induced as proposed in earlier works. The pyramids are of such regular size, shape and spacing that light is selectively absorbed and for 40 keV argon ion bombardment, only light of red colour is reflected from an initially plane surface. (Auth.)

  12. Cryopumping hydrogen isotope mixtures in MFTF-B with and without argon adsorbent

    International Nuclear Information System (INIS)

    Mixtures of hydrogen isotopes, primarily deuterium (D2), protium-deuterium (HD), and protium (H2) must be pumped by the vacuum system in the Mirror Fusion Test Facility at Lawrence Livermore National Laboratory. In this study, we used argon as an adsorbent for cryopumping these isotopes at 4.2 K and found that deuterium will displace already adsorbed protium. Thus, when we pump mixtures of the two, sufficient argon must be supplied to adsorb both species. We also found that without argon, deuterium will cryptrap protium in accord with Raoult's law

  13. Development of a Laser Probe for Argon Isotope Studies.

    Science.gov (United States)

    McConville, Paul

    Available from UMI in association with The British Library. The first objective of this study was to develop a laser outgassing facility for argon isotope studies. Apart from the laser and construction of the laser sample port, existing vacuum and mass spectrometer systems were used. Laser performance and optimum operating conditions were investigated. The second objective was test and evaluate the laser extraction technique by studies of simple geological samples. Previous laser ^{40} Ar-^{39}Ar dating studies by other workers had not systematically established the basis or characteristics of the method. Results from laser and complementary stepped heating studies of the ^{40}Ar-^ {39}Ar dating standard hornblende, hb3gr; a phlogopite sample from the Palabora (Phalaborwa) Complex; and biotites in a thin section of the Hamlet Bjerg granite from East Greenland, verified that: (1) Laser extraction reproduced within experimental error the stepped heating ^{40}Ar-^ {39}Ar and K-Ar ages of simple samples. (2) The precision of the technique i.e. the amount of sample required to give reliable ages, was limited in the present experiments largely by the level of the blanks and backgrounds to 10-100 ug samples. (3) Sample outgassing appeared to be limited to the order of 10 um outside the physical size of the laser pit, consistent with other estimates of the spatial definition in the literature. This could be understood by thermal diffusion and the length of the laser pulse. (4) The efficiency of the laser pulse in melting and outgassing mineral samples was shown to be dependent on silicate latent heats and mineral absorption at the laser wavelength. In addition, the ^{40} Ar-^{39}Ar age of the geologically significant Palabora Complex was determined as (2053 +/- 5) Ma. Excess argon led to a discrepancy between the laser and stepped heating ages of biotite and muscovite, (405 +/- 5) Ma, and laser ages of feldspars (510 +/- 20) Ma in the Hamlet Bjerg granite. This illustrated

  14. Removal of iron contaminant from zirconium chloride solution

    International Nuclear Information System (INIS)

    This patent describes a process for eliminating iron contaminant from an aqueous zirconium chloride solution that has been contaminated with FeCl3 in a plant in which zirconium and hafnium chloride solutions are separated by a main MINK solvent extraction system and the FeCl3 is normally removed from the zirconium chloride solution by a secondary MINK solvent extraction system

  15. Kinetics of Vinyl Chloride Polymerization with Mixture of Initiators

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Kinetic models for the rate constants of vinyl chloride polymerization in the presence of initiator mixtures were proposed. They may be used to design the initiator recipes for the vinyl chloride polymerization with uniform rate at different temperatures at which various grades of poly(vinyl chloride) will be prepared.

  16. Revised Model of Chloride Diffusion in Concrete Bridge by Considering Complex Action of Load and Chloride Binding Capacity

    OpenAIRE

    Xiang, Yiqiang; Guo, DongMei

    2014-01-01

    Coastal concrete bridges will suffer from deterioration of RC structural performance and resistance attenuation because of the chloride penetration and other environment factors. This article discusses current different chloride diffusion models and puts forward the revised model of chloride diffusion in concrete bridge by considering the complex action of load influence and chloride-binding capacity. Comparison of numerical predicted values and relative experimental tests show the presented ...

  17. Dynamic range compression in a liquid argon calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Cleland, W.E. [Univ. of Pittsburgh, PA (United States); Lissauer, D.; Radeka, V.; Rescia, S.; Takai, H. [Brookhaven National Lab., Upton, NY (United States); Wingerter-Seez, I. [LAPP, Annecy-le-Vieux (France)

    1996-12-31

    The anticipated range of particle energies at the LHC, coupled with the need for precision, low noise calorimetry makes severe demands on the dynamic range of the calorimeter readout. A common approach to this problem is to use shapers with two or more gain scales. In this paper, the authors describe their experience with a new approach in which a preamplifier with dynamic gain compression is used. An unavoidable consequence of dynamic gain adjustment is that the peaking time of the shaper output signal becomes amplitude dependent. The authors have carried out a test of such a readout system in the RD3 calorimeter, a liquid argon device with accordion geometry. The calibration system is used to determine both the gain of the individual channels as well as to map the shape of the waveform as a function of signal amplitude. A new procedure for waveform analysis, in which the fitted parameters describe the impulse response of the system, permits a straightforward translation of the calibration waveform to the waveform generated by a particle crossing the ionization gap. They find that the linearity and resolution of the calorimeter is equivalent to that obtained with linear preamplifiers, up to an energy of 200 GeV.

  18. Interaction of an argon plasma jet with a silicon wafer

    Science.gov (United States)

    Engelhardt, Max; Pothiraja, Ramasamy; Kartaschew, Konstantin; Bibinov, Nikita; Havenith, Martina; Awakowicz, Peter

    2016-04-01

    A filamentary discharge is ignited in an argon plasma jet under atmospheric pressure conditions. The gas discharge is characterized with voltage-current measurements, optical emission spectroscopy and an ICCD-camera with a high temporal resolution down to 10 ns. In the effluent of the plasma jet, filaments come into contact with the surface of a silicon wafer and modify it, namely etching traces are produced and microcrystals are deposited. These traces are studied with optical and electron microscopes. The material of the deposited microcrystals and the surface modifications of the silicon wafer are analyzed with Raman microspectroscopy. Amorphous silicon is found within the etching traces. The largest part of the deposited microcrystals are composed of nitratine (NaNO3) and some of them are calcite (CaCO3). Analyzing the possible reasons for the silicon wafer modifications we come to the conclusion that plasmoids, which are produced near the substrate surface by interaction with ionization waves, are a plausible explanation for the observed surface modifications of the silicon wafer.

  19. State-selective radiative recombination cross sections of argon ions

    International Nuclear Information System (INIS)

    The n-, (n,l)- and fine-structure level state-selective radiative recombinations (RR) cross sections of argon ions Ar18+,Ar13+,Ar7+ and Ar+ are obtained with the semi-classical Kramer formula, the relativistic self-consistent field (RSCF) method and the relativistic configuration interaction (RCI) method. It is found that for the highly charged ions with few electrons, the cross sections calculated with these three methods are in good agreement with each other. But as the number of electrons increases, the Kramer formula deviates from the RSCF and RCI results. For instance, when the energy of the incident electron is larger than 100 eV, the n-state selective cross sections of Ar7+ calculated from the Kramer formula are underestimated for more than 50%. The RSCF results are in general agreement with the RCI results. However, for the low charged ions, a clear distinction appears due to the strong configuration interaction, especially near the Cooper minimum. The n-resolved (n≤10) and total Maxwellian averaged rate coefficients are calculated, and the analytic fitting parameters are also provided. -- Highlights: ► The RR cross sections of Ar18+, Ar13+, Ar7+ and Ar+ are obtained. ► The Kramer formula, the relativistic self-consistent field and RCI methods are used. ► Results from three methods are compared with each other.

  20. Scintillation Light from Cosmic-Ray Muons in Liquid Argon

    CERN Document Server

    Whittington, Denver

    2014-01-01

    This paper reports the results of the first experiment to directly measure the properties of the scintillation light generated by minimum ionizing cosmic-ray muons in liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches, as well as for particle identification. The experiment was carried out at the TallBo facility at Fermilab using prototype light guides and electronics developed for the Long-Baseline Neutrino Experiment. Analysis of the time-resolved structure of the scintillation light from cosmic-ray muons gives $\\langle \\tau_{\\text{T}}\\rangle = 1.43 \\pm 0.04~\\text{(stat.)} \\pm 0.007~\\text{(sys.)}~\\mu$s for the triplet light decay time constant. The ratio of singlet to triplet light measured using surface-coated light guides is $R = 0.39 \\pm 0.01~\\text{(stat.)} \\pm 0.008~\\text{(sys.)}$. There is some evidence that this value is not consistent with $R$ for minimum ionizing electrons. However, the value for $...

  1. Single nucleon heavy ion transfer reactions on argon isotopes

    International Nuclear Information System (INIS)

    Single nucleon transfer reactions, both pickup and stripping, on all three stable isotopes of argon - 36Ar, 38Ar and 40Ar - have been studied using a 11B projectile at a laboratory energy of 116 MeV. Using a gas target, the forward angle reaction cross-sections were measured with a telescope of silicon surface barrier detectors. The shape of the differential cross-section is discussed in terms of a semiclassical reaction analysis. An exact finite range DWBA code has been used to extract the spectroscopic factors of the strongly populated states and the spectroscopic factors are compared with those obtained using light ion transfer reactions. The excitation energies and spectroscopic factors of levels in nuclei in the mass range A=35-41 are modelled using various effective shell model interactions. Both a complete sd shell space and a space incorporating parts of the sd and fp shells have been used. The results of a phenomenological modified surface delta interaction are compared with those of interactions based on the realistic interaction matrix elements of Kuo. (author)

  2. Methane from benzene in argon dielectric barrier discharge

    International Nuclear Information System (INIS)

    Highlights: ► Efficient on-line conversion of benzene to methane at room temperature. ► Absence of other H-atom donor suggests new type of chemistry. ► For parent loss > 90%, methane yield was ∼40% of limit due to H-atom availability. ► Surface moisture contributed ·OH radical for trace phenolic products’ formation. ► This method may emerge as an exploitable tactic for pollutants’ usable alterations. -- Abstract: A first-time account of direct, on-line, instantaneous and efficient chemical conversion of gas phase benzene to methane in argon Dielectric Barrier Discharge (DBD) is presented. In the absence of another overt hydrogen-donating source, potency of analogous parents toward methane generation is found to follow the order: benzene > toluene > p-xylene. Simultaneous production of trace amounts of phenolic surface deposits suggest (a) prompt decomposition of the parent molecules, including a large fraction yielding atomic transients (H-atom), (b) continuous and appropriate recombination of such parts, and (c) trace moisture in parent contributing ·OH radicals and additional H-atoms, which suitably react with the unreacted fraction of the parent, and also other intermediates. Results highlight Ar DBD to be a simple and exploitable technology for transforming undesirable hazardous aromatics to usable/useful low molecular weight open-chain products following the principles of green chemistry and engineering

  3. Accurate calculations of bound rovibrational states for argon trimer

    Energy Technology Data Exchange (ETDEWEB)

    Brandon, Drew; Poirier, Bill [Department of Chemistry and Biochemistry, and Department of Physics, Texas Tech University, Box 41061, Lubbock, Texas 79409-1061 (United States)

    2014-07-21

    This work presents a comprehensive quantum dynamics calculation of the bound rovibrational eigenstates of argon trimer (Ar{sub 3}), using the ScalIT suite of parallel codes. The Ar{sub 3} rovibrational energy levels are computed to a very high level of accuracy (10{sup −3} cm{sup −1} or better), and up to the highest rotational and vibrational excitations for which bound states exist. For many of these rovibrational states, wavefunctions are also computed. Rare gas clusters such as Ar{sub 3} are interesting because the interatomic interactions manifest through long-range van der Waals forces, rather than through covalent chemical bonding. As a consequence, they exhibit strong Coriolis coupling between the rotational and vibrational degrees of freedom, as well as highly delocalized states, all of which renders accurate quantum dynamical calculation difficult. Moreover, with its (comparatively) deep potential well and heavy masses, Ar{sub 3} is an especially challenging rare gas trimer case. There are a great many rovibrational eigenstates to compute, and a very high density of states. Consequently, very few previous rovibrational state calculations for Ar{sub 3} may be found in the current literature—and only for the lowest-lying rotational excitations.

  4. Coherent set of electron cross sections for argon

    Science.gov (United States)

    Alves, L. L.; Ferreira, C. M.

    2011-10-01

    This paper presents a coherent set of electron impact cross sections for argon (elastic momentum-transfer, inelastic for the excitation of 37 levels Ar(4s,4p,3d,5p,4d,6s) and ionization), which was recently uploaded onto the LXcat IST-Lisbon database. The cross section set was validated by comparing calculated swarm parameters (electron mobility and characteristic energy) and rate coefficients (Townsend ionization coefficient and direct + cascade excitation coefficients to the 4s and 4p states) with available experimental data, for E / N = 10-4 - 100 Td and Tg = 300, 77 K. The validation procedure involves the solution to the homogeneous two-term electron Boltzmann equation, resorting to three different solvers: (i) IST-Lisbon's (ii) BOLSIG+ (v1.2) with LXcat; (iii) BOLSIG+ (v1.23). The results obtained with these solvers are compared to evidence the importance of certain numerical features related with both the energy-grid (number of points, grid-type and maximum energy value) and the interpolation scheme adopted for the cross sections. In particular, the latter can cause a 6% variation on the values of swarm parameters at intermediate E/Ns.

  5. An update of argon inelastic cross sections for plasma discharges

    International Nuclear Information System (INIS)

    This paper proposes a coherent set of electron impact inelastic cross sections for argon, based on recent experimental measurements. The updated set is validated by comparing calculated swarm parameters and rate coefficients (obtained by solving the two-term approximation electron Boltzmann equation) with available experimental data. This validation procedure is usually adopted when the cross section set is to be later used in plasma discharge modelling. Simulation results for the electron drift velocity and characteristic energy are in very good agreement with experimental values of these quantities. Calculations, using cross section sets proposed by different authors, of the total (direct + cascade) excitation coefficients to the 4s and 4p states, and of the Townsend ionization coefficient, show that the present set ensures the best overall agreement with measured values. The agreement is particularly good for the excitation coefficient to metastable 4s'[1/2]0 and the Townsend ionization coefficient, which are probably the most relevant electron macroscopic coefficients in the modelling of discharge plasmas

  6. Accurate calculations of bound rovibrational states for argon trimer

    International Nuclear Information System (INIS)

    This work presents a comprehensive quantum dynamics calculation of the bound rovibrational eigenstates of argon trimer (Ar3), using the ScalIT suite of parallel codes. The Ar3 rovibrational energy levels are computed to a very high level of accuracy (10−3 cm−1 or better), and up to the highest rotational and vibrational excitations for which bound states exist. For many of these rovibrational states, wavefunctions are also computed. Rare gas clusters such as Ar3 are interesting because the interatomic interactions manifest through long-range van der Waals forces, rather than through covalent chemical bonding. As a consequence, they exhibit strong Coriolis coupling between the rotational and vibrational degrees of freedom, as well as highly delocalized states, all of which renders accurate quantum dynamical calculation difficult. Moreover, with its (comparatively) deep potential well and heavy masses, Ar3 is an especially challenging rare gas trimer case. There are a great many rovibrational eigenstates to compute, and a very high density of states. Consequently, very few previous rovibrational state calculations for Ar3 may be found in the current literature—and only for the lowest-lying rotational excitations

  7. Imaging of hydrogen halides photochemistry on argon and ice nanoparticles

    International Nuclear Information System (INIS)

    The photodissociation dynamics of HX (X = Cl, Br) molecules deposited on large ArN and (H2O)N, N¯≈ 102–103, clusters is investigated at 193 nm using velocity map imaging of H and Cl photofragments. In addition, time-of-flight mass spectrometry after electron ionization complemented by pickup cross section measurements provide information about the composition and structure of the clusters. The hydrogen halides coagulate efficiently to generate smaller (HX)n clusters on ArN upon multiple pickup conditions. This implies a high mobility of HX molecules on argon. On the other hand, the molecules remain isolated on (H2O)N. The photodissociation on ArN leads to strong H-fragment caging manifested by the fragment intensity peaking sharply at zero kinetic energy. Some of the Cl-fragments from HCl photodissociation on ArN are also caged, while some of the fragments escape the cluster directly without losing their kinetic energy. The images of H-fragments from HX on (H2O)N also exhibit a strong central intensity, however, with a different kinetic energy distribution which originates from different processes: the HX acidic dissociation followed by H3O neutral hydronium radical formation after the UV excitation, and the slow H-fragments stem from subsequent decay of the H3O. The corresponding Cl-cofragment from the photoexcitation of the HCl·(H2O)N is trapped in the ice nanoparticle

  8. Electronics calibration board for the ATLAS liquid argon calorimeters

    International Nuclear Information System (INIS)

    To calibrate the energy response of the ATLAS liquid argon calorimeter, an electronics calibration board has been designed; it delivers a signal whose shape is close to the calorimeter ionization current signal with amplitude up to 100 mA in 50 Ω with 16 bit dynamic range. The amplitude of this signal is designed to be uniform over all calorimeters channels, stable in time and with an integral linearity much better that the electronics readout. The various R and D phases and most of the difficulties met are discussed and illustrated by many measurements. The custom design circuits are described and the layout of the ATLAS calibration board presented. The procedure used to qualify the boards is explained and the performance obtained illustrated: a dynamic range up to 3 TeV in three energy scales with an integral linearity better than 0.1% in each of them, a response uniformity better than 0.2% and a stability better than 0.1%. The performance of the board is well within the ATLAS requirements. Finally, in situ measurements done on the ATLAS calorimeter are shown to validate these performances

  9. Final report on demonstration of movable Argon-37

    International Nuclear Information System (INIS)

    A prototype of Movable Argon-37 Rapid Detection System for the mission of on-site inspection under the CTBT was developed. In order to demonstrate the performance and its feasibility for OSI, the demonstration of MARDS-I was held. In the period of the demonstration, the specification and technical capability of MARDS-I was demonstrated by four experiments: experiment on vehicle transportation in rugged countryside; experiment on rapid separation, purification and measurement of simulating samples; experiment on rapid separation, purification and measurement of underground samples; the effectiveness of sampling process. these experimental results are certified scientifically by gas chromatograph analysis in laboratory. the results show that the MDC of the system is less than 1 Bq/m3 that meet the practical requirements of OSI in field for detecting 1 kt underground nuclear explosion during a period of several months after the explosion. MARDS-I is movable, rapid and in small size. Otherwise, there is still room for further improvement of the system, e.g. reliability enhancement, reduction of the MDC, upgrading automation of system. (authors)

  10. Summary of the liquid argon calorimeter hermeticity working group

    International Nuclear Information System (INIS)

    The cryogenic nature, and hence the need to provide thermal insulation, of liquid argon calorimeters is known to pose serious problems for precise measurements of missing transverse energy, a key signature for new physics at the SSC. This problem is exacerbated by the central detector requirement of access to both sides of the detector. The original DiGiacomo et al. design sought to satisfy this access requirement and still minimize the effect of electromagnetic showers by protruding the end cap calorimeter into the central volume. This design was compared with two design variations by using a parameterization of hadronic and electromagnetic showers assuming no transverse width. These authors concluded that a flat head End Cap design was preferable to the original design for both electromagnetic and hadronic showers. The practical design advantages of this method was further demonstrated by the conclusions that instrumented calorimeter volumes which are not thick enough to absorb most of an electromagnetic shower before a dead volume enhance the resolution degradation. This means, for instance, that calorimeter modules should have their large eta edge on the front face beveled to decrease the effect of the structural washers separating the calorimeter module bays

  11. Argon defect complexes in low energy Ar irradiated molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    van Veen, A.; Buters, W.T.M.; van der Kolk, G.J.; Caspers, L.M. (Interuniversitair Reactor Instituut, Delft (Netherlands)); Armstrong, T.R. (Victoria Univ., Wellington (New Zealand). Dept. of Physics)

    1982-03-15

    Thermal desorption spectrometry has been used to study the defects created in Mo irradiated along the <110> direction with Ar ions ranging in energy from 0.1 to 2 keV. In addition to monitoring the release of the implanted Ar, additional information has been obtained by decoration of the defects with low energy helium and subsequent monitoring of the helium release. The studies show evidence that the Ar can be trapped in both substitutional sites and in a configuration in which the Ar is associated with vacancies (ArVsub(n), n >= 2). Most of the Ar implanted at high energy is released at approx. equal to 1500 K by thermal vacancy assisted diffusion. Argon trapped closer to the surface is released at lower temperatures via at least three different surface related release mechanisms. Additional results are presented on the interaction of self interstitial atoms (introduced by 100 eV Xe bombardment) with the Ar defects. Substitutional Ar is found to convert to interstitial Ar which seems to be mobile at room temperature. The Ar-vacancy complexes are found to be reduced to substitutional Ar. The results of atomistic calculations of the release mechanisms will also be presented.

  12. ECR Plasma Sterilisation, Argon and Nitrogen Treated Plasma

    Science.gov (United States)

    Helhel, Selcuk; Oksuz, Lutfi; Cerezci, Osman; Rad, Abbas Y.

    2004-09-01

    ECR type plasma system was built to produce plasma in axial direction. Plasma was initiated in a specially designed Nickel - Chrome cylindrical vacuum tube which is being driven through dielectric window by 2.45GHz commercial magnetron source. Tube is also surrounded by a coil driving 150ADC to generate approximately 875Gauss magnetic field at the center. Langmuir probe and ICCD for optical spectrometry were used to characterize internal parameters like electron density, electron temperature and different characteristics of the plasma. Bacillus Subtilis var nigar, bacillus Stearothermophilus, bacillus pumilus E601, Escherichia coli and staphylococcus aureus type bacteria were selected as a reference. Each is resistant for different actions while the Bacilus cereus is the most resistant bacteria for microwave interaction. This study presents the effect of system on used bacteria. Those are gram positive and gram negative bacteria that refers to structure of cell wall. The sterilization efficacy of Argon type ECR plasma was found to be over 99, 5% in Staphylococcus aureus, Staphylococcus epidermidis, Bacillus subtilis (vegetative cell), Bacillus cereus (vegetative cell), Bacillus pumilus and Escherichia coli. System response type is less than 2 minutes.

  13. Surface Chemistry of Polymers Physical Adsorption of Nitrogen, Argon, Sulfur Dioxide and Neopentane on Polyvinylidene Fluoride

    OpenAIRE

    Houriet, Jean-Philippe; Ghiste, Patrick; Stoeckli, Fritz

    2007-01-01

    The adsorption of nitrogen, argon, sulfur dioxide and neopentane on polyvinylidene fluoride has been measured by static methods and by gas-solid chromatography. The polymer has a homogeneous surface of low energy, which is not significantly affected by heating.

  14. Photofragmentation and photoabsorption cross sections for mass selected argon cluster ions, n = 3 to 108

    International Nuclear Information System (INIS)

    A tandem time-of-flight mass spectrometer is used to measure photofragmentation mass spectra and optical absorption spectra of mass selected argon cluster ions in the n=3 to 108 atoms per cluster range. (orig.)

  15. Influence of oxygen traces on an atmospheric-pressure radio-frequency capacitive argon plasma discharge

    International Nuclear Information System (INIS)

    An atmospheric-pressure capacitive discharge source driven by radio-frequency power supply at 13.56 MHz has been developed experimentally that is capable of producing a homogeneous and cold glow discharge in O2/Ar. With respect to the influence of oxygen component when diluted into argon plasma discharge on the discharge characteristics, the measurements of the electrical parameters (impedance, phase angle, resistance, and reactance) are made systematically and the densities of the metastable and resonant state of argon are determined by means of optical emission spectroscopy (OES). It is shown that the admixture of oxygen into argon plasma not only changes the electric characteristics but also alters the optical emission spectra greatly due to strong interaction between the oxygen content and the argon in the plasma environment.

  16. Liquid argon pollution tests of ATLAS detector materials at the IBR-2 reactor in Dubna

    CERN Document Server

    Leroy, C; Golubyh, S M; Kukhtin, V; Merkulovm L; Minashkin, V F; Golikov, V V; Kulagin, E N; Luschikov, V; Golovanov, L B; Borzunov, Yu T; Chumakov, V; Tsvinev, A P; Shalyugin, A N

    2002-01-01

    aA cold irradiation test facility operated at the IBR-2 reactor of JINR, Dubna, is used to investigate the behaviour under neutron and gamma irradiations of samples of materials and equipments to be used in the ATLAS forward (FCAL) and the hadronic end cap (HEC) liquid argon calorimeters. The samples under study are immersed in a liquid argon cryostat and exposed to fast neutron (E/sub n/ >or= 100 keV) fluences of about 10/sup 16/ n cm/sup -2/ equivalent to the neutron fluence accumulated in FCAL during ten years of LHC operation. An alpha -cell is used to check for possible outgassing due to irradiation of the samples immersed in liquid argon and to monitor the liquid argon purity. The results of various irradiation tests performed at this facility are reported. (6 refs).

  17. Formation and characterization of magnesium bisozonide and carbonyl complexes in solid argon.

    Science.gov (United States)

    Wang, Guanjun; Gong, Yu; Zhang, Qingqing; Zhou, Mingfei

    2010-10-14

    The reactions of magnesium atoms with dioxygen and dioxygen/carbon monoxide mixture have been investigated by matrix isolation infrared absorption spectroscopy. Magnesium atoms react with dioxygen in solid argon to form the inserted MgO(2) molecules under UV excitation, which were previously characterized. Annealing allows the dioxygen molecules to diffuse and to react with MgO(2) and form the magnesium bisozonide complex, Mg(O(3))(2), which is proposed to be coordinated by two argon atoms in solid argon matrix. The Mg(O(3))(2)(Ar)(2) complex is characterized to have two equivalent side-on bonded ozonide ligands with a D(2h) symmetry. The coordinated argon atoms can be replaced by carbon monoxide to give the magnesium bisozonide dicarbonyl complex, Mg(O(3))(2)(CO)(2), a neutral magnesium carbonyl complex with CO binding to the Mg(2+) center. PMID:20857987

  18. SEM investigation of surface blistering for argon ion bombarded amorphous alloys

    International Nuclear Information System (INIS)

    Surface blistering of the amorphous alloys Co70.2Fe3.9Nb3.9Si14B8 and Co66Fe4.5V2.25Ni2.25Si10B15 due to argon ion bombardment at energies of 150, 195 and 300 keV has been observed with a scanning electron microscope (SEM). The critical dose for onset of blistering and the blister diameter are determined and found to increase with increasing projectile energy. Above about 195 keV, blisters and rupture of blisters are the predominant surface damage phenomena. However, at 150 keV, there is no evidence of cracked blisters. The effects are interpreted in terms of argon agglomeration, building-up of the critical argon pressure, and argon releasing from near-surface regions

  19. Energy resolution for 1 MeV electrons in liquid argon doped with allene

    International Nuclear Information System (INIS)

    The energy spectrum of conversion electrons (976 keV) from 207Bi has been measured by an ionization chamber filled with pure or allene-doped liquid argon. The collected charge in allene-doped liquid argon was increased compared to that in pure liquid argon. The resolution was not improved by doping liquid argon with allene in high electric fields, but it was improved in low fiels. This indicates that the recombination process is not a main cause of the observed resolutions. The best resolution was about 30 keV which is the same as the best value obtained so far. This is several times worse than the theoretical ultimate value based on the Fano factor. (orig.)

  20. Surface modification of polypropylene using argon plasma: Statistical optimization of the process variables

    International Nuclear Information System (INIS)

    Low pressure plasma treatment using radiofrequency (rf) discharge of argon gas was employed to improve the hydrophilicity of polypropylene. The effects of argon plasma on the wettability, surface chemistry and surface morphology of polypropylene were studied using static contact angle measurements, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and atomic force microscopy (AFM). Increase in surface energy of polypropylene was observed as a result of argon plasma treatment. SEM and AFM images revealed the increased surface roughness. A set of identified process variables (rf power, pressure, argon flow rate and time) were used in this study and were optimized using central composite design (CCD) of response surface methodology (RSM). A statistical model was developed to represent the surface energy in terms of the process variables mentioned above. Accuracy of the model was verified and found to be high.

  1. An Experimental Study of the Electrical Conductivity of an Argon Plasma with an Ionizing Additive

    International Nuclear Information System (INIS)

    The electrical conductivity of a weakly ionized argon plasma in a direct current arc was determined experimentally. The paper describes the experimental rig, which consists of an arc heater giving an argon stream with a temperature of 1000-2000°K and a measuring section. An experimental method is proposed for varying the ratio between the contaminated and neutral components of the plasma over a wide range by introducing an easily ionizable seed. Measurements were carried out at temperatures of 4000-5000°K for contaminated particle concentrations in the range 1013-1015 cm-3. The experimental data were used to study the validity of different approximations of the Chapman-Cowling theory as applied to calculating the electric conductivity of a weakly ionized argon plasma. It is shown that the fourth approximation of the theory is unsatisfactory for calculating the electrical conductivity of an argon plasma in the range of contaminated particle concentrations concerned. (author)

  2. Lead Pipe Scale Analysis Using Broad-Beam Argon Ion Milling to Elucidate Drinking Water Corrosion

    Science.gov (United States)

    Herein, we compared the characterization of lead pipe scale removed from a drinking water distribution system using two different cross section methods (conventional polishing and argon ion beam etching). The pipe scale solids were analyzed using scanning electron microscopy (SEM...

  3. Performance of semiconducting oxide based hydrogen sensor for argon cover gas in engineering scale sodium facility

    International Nuclear Information System (INIS)

    Highlights: • Testing of tin oxide based sensor for trace levels of hydrogen in argon. • These experiments were carried out in engineering scale sodium facilities. • For identification of leak in the steam generator section of fast reactor. • Instantaneous sensing of down to 5 vppm of hydrogen in argon. • Sensing is equivalent to a few tens of milligrams (10−2 g) of water leak into 106 g of sodium. - Abstract: Tin oxide based thin film sensors were tested for low levels of hydrogen in argon cover gas over sodium system in engineering scale facility. The sensor responded to down to 5 volume parts per million (vppm) level of hydrogen in argon and was possible to detect up to 100 vppm reliably. The sensor response was corroborated with the output of thermal conductivity detector (TCD) based system

  4. Spectroscopic characterization of a radio-frequency argon plasma jet discharge in ambient air

    Science.gov (United States)

    Cullen, P. J.; Milosavljević, V.

    2015-06-01

    This study includes a detailed experimental investigation of the spatial and temporal spectroscopic emission of an argon plasma jet discharge. The study is carried out in ambient air and quenching by inflowing air species is considered. The optical emission spectroscopy of neutral atomic spectral lines and molecular bands, over a range of plasma process parameters, is investigated. Wavelength-resolved argon optical emission profiles are used to monitor the electron energy distribution function and the density of argon metastable atoms. The experimental data indicates that the argon flow rate, in a confined open-air plasma discharge, limits the impact of molecular oxygen in the creation of oxygen radicals. The absolute calibrated emission spectra facilitate the possibility of standardization of the so-called plasma dose.

  5. Pose Measurement Performance of the Argon Relative Navigation Sensor Suite in Simulated Flight Conditions

    Science.gov (United States)

    Galante, Joseph M.; Eepoel, John Van; Strube, Matt; Gill, Nat; Gonzalez, Marcelo; Hyslop, Andrew; Patrick, Bryan

    2012-01-01

    Argon is a flight-ready sensor suite with two visual cameras, a flash LIDAR, an on- board flight computer, and associated electronics. Argon was designed to provide sensing capabilities for relative navigation during proximity, rendezvous, and docking operations between spacecraft. A rigorous ground test campaign assessed the performance capability of the Argon navigation suite to measure the relative pose of high-fidelity satellite mock-ups during a variety of simulated rendezvous and proximity maneuvers facilitated by robot manipulators in a variety of lighting conditions representative of the orbital environment. A brief description of the Argon suite and test setup are given as well as an analysis of the performance of the system in simulated proximity and rendezvous operations.

  6. STABILISATION OF SILTY CLAY SOIL USING CHLORIDE

    Directory of Open Access Journals (Sweden)

    TAMADHER T. ABOOD

    2007-04-01

    Full Text Available The object of this paper is to investigate the effect of adding different chloride compounds including (NaCl, MgCl2, CaCl2 on the engineering properties of silty clay soil. Various amounts of salts (2%, 4%, and 8% were added to the soil to study the effect of salts on the compaction characteristics, consistency limits and compressive strength. The main findings of this study were that the increase in the percentage of each of the chloride compounds increased the maximum dry density and decrease the optimum moisture content. The liquid limit, plastic limit and plasticity index decreased with the increase in salt content. The unconfinedcompressive strength increased as the salt content increased.

  7. BARRIER PROPERTIES OF VINYLIDENE CHLORIDE COPOLYMERS

    Institute of Scientific and Technical Information of China (English)

    LI Yuesheng; WENG Zhixue; HUANG Zhiming; PAN Zuren

    1996-01-01

    The permeability coefficients of a series of copolymers of vinylidene chloride (VDC)with methyl acrylate (MA), butyl acrylate (BA) or vinyl chloride (VC) (as comonomer)to oxygen and carbon dioxide have been measured at 1.0 MPa and 30℃, while those to water vapor have been measured at 30℃ and 100% relative humidity. All the copolymers are semicrystalline. VDC/MA copolymers have lower melting temperature compared with VDC/BA copolymers, while that melting temperature of VDC/VC copolymer is higher than that of VDC/acrylate copolymers with the same VDC content. The barrier property of the copolymers is predominantly controlled by crystallite, free volume fraction, and cohesive energy. The permeability coefficients of VDC/MA copolymers to oxygen, carbon dioxide, and water vapor were successfully correlated with the ratio of free volume to cohesive energy.

  8. Chloride migration in concrete with superabsorbent polymers

    DEFF Research Database (Denmark)

    Hasholt, Marianne Tange; Jensen, Ole Mejlhede

    2015-01-01

    Superabsorbent polymers (SAP) can be used as a means for internal curing of concrete. In the present study, the development of transport properties of concrete with SAP is investigated. The chloride migration coefficient according to NT BUILD 492 is used as a measure of this. Twenty concrete...... mixtures are tested 7, 14, and 28 days after casting. The development of degree of hydration is followed for 20 corresponding paste mixtures. Both when SAP is added with extra water to compensate the SAP water absorption in fresh concrete and without extra water, the internal curing water held by SAP may...... contribute to increase the degree of hydration. No matter if SAP is added with or without extra water, it appears that the so-called gel space ratio can be used as a key parameter to link age and mixture proportions (water-to-cement ratio and SAP dosage) to the resulting chloride migration coefficient; the...

  9. Vacuum ultraviolet argon excimer laser excited by optical-field-induced ionized electrons produced in an argon-filled hollow fiber

    Science.gov (United States)

    Kubodera, Shoichi; Kaku, Masanori; Katto, Masahito

    2011-10-01

    Short-wavelength lasers in the vacuum ultraviolet (VUV) spectral region between 100 and 200 nm have not yet been developed to the same degree as visible and infrared lasers. We have demonstrated the production of argon excimers via an optical-field-induced ionization (OFI) process by using a high-intensity infrared laser. We here report optical amplification of argon excimers at the wavelength of 126 nm by producing an extended OFI plasma inside an argon-filled hollow fiber with an inner diameter of 250 microns with a length of 5.0 cm. A gain-length product of 4.3 through the use of single-pass amplification with VUV optics was observed, indicating a small signal gain coefficient of 0.86 cm-1 with an uncertainty of 0.03. It was found that the hollow fiber served to extend the OFI plasma length and to guide the excitation of the infrared laser and the produced VUV emissions at 126 nm, but did not affect the OFI plasma conditions to produce argon excimer molecules. Short-wavelength lasers in the vacuum ultraviolet (VUV) spectral region between 100 and 200 nm have not yet been developed to the same degree as visible and infrared lasers. We have demonstrated the production of argon excimers via an optical-field-induced ionization (OFI) process by using a high-intensity infrared laser. We here report optical amplification of argon excimers at the wavelength of 126 nm by producing an extended OFI plasma inside an argon-filled hollow fiber with an inner diameter of 250 microns with a length of 5.0 cm. A gain-length product of 4.3 through the use of single-pass amplification with VUV optics was observed, indicating a small signal gain coefficient of 0.86 cm-1 with an uncertainty of 0.03. It was found that the hollow fiber served to extend the OFI plasma length and to guide the excitation of the infrared laser and the produced VUV emissions at 126 nm, but did not affect the OFI plasma conditions to produce argon excimer molecules. Part of this work has been supported by

  10. Influence of chloride admixtures on cement matrix durability

    International Nuclear Information System (INIS)

    The influence of various inorganic salts, as chloride admixtures to Portland cement, on the mechanical properties and the durability of the matrix has been studied. The salts used in this study are chromium, nickel and cadmium chlorides. Improved compressive strength values are obtained which have been correlated to the stable metal hydroxide formation in high pH environment. Under static water conditions at 500C, hydrolyzed chloride ions exhibit adverse effects on the matrix durability through rapid release of calcium as calcium chloride in the initial period of leaching. On the contrary, enhanced matrix durability is obtained on long term leaching in the case of cement containing chromium chloride

  11. Acylation of Toluene with Isobutyryl Chloride

    Czech Academy of Sciences Publication Activity Database

    Čejka, Jiří; Klisáková, Jana; Žilková, Naděžda; Červený, L.

    Cape Town, 2004 - ( Steen van, E.), s. 2717-2723 ISBN 0-958-46636-X. [International Zeolite Conference /14./. Cape Town (ZA), 25.04.2004-30.04.2004] R&D Projects: GA ČR GA203/03/0804 Institutional research plan: CEZ:AV0Z4040901 Keywords : acylation of toluene * isobutyryl chloride * zeolites Subject RIV: CF - Physical ; Theoretical Chemistry

  12. Chloride migration in concrete with superabsorbent polymers

    OpenAIRE

    Hasholt, Marianne Tange; Jensen, Ole Mejlhede

    2015-01-01

    Superabsorbent polymers (SAP) can be used as a means for internal curing of concrete. In the present study, the development of transport properties of concrete with SAP is investigated. The chloride migration coefficient according to NT BUILD 492 is used as a measure of this. Twenty concrete mixtures aretested 7, 14, and 28 days after casting. The development of degree of hydration is followed for 20 corresponding paste mixtures.Both when SAP is added with extra water to compensate the SAP wa...

  13. Gasometric titration for dimethylaluminum chloride analysis.

    Science.gov (United States)

    Wang, Lin; Maligres, Peter; Eckenroad, Kyle; Simmons, Bryon

    2016-06-01

    A gasometric titration method was developed to quantitate active alkylaluminum content in dimethylaluminum chloride solution to perform the stoichiometry calculation for the reaction charge. The procedure was reproducible with good precision, and the results showed good correlation with ICP-MS method. The gasometric titration is a simple, inexpensive alternative to analysis via ICP-MS which provides more selective analysis of methylaluminum species without the need for inertion. PMID:27017569

  14. A Duplex Stainless Steel for Chloride Environments

    Science.gov (United States)

    Sridhar, N.; Kolts, J.; Flasche, L. H.

    1985-03-01

    This paper examines the effects of microstructural changes on the corrosion, stress corrosion cracking and corrosion fatigue resistance of a duplex stainless steel to chloride environments. The microstructural changes can be precipitation of phases such as sigma and carbides, or changes in the distribution of austenite and ferrite. The former can be important in hot forming operations while the latter is important in welding. The methods of minimizing these deleterious effects can sometimes be different from those used for austenitic stainless steel.

  15. Electrodeposition of Zinc from Chloride Solution

    OpenAIRE

    NAIK, Yanjerappa Arthoba; VENKATESHA, Thimmappa Venkatarangaiah

    2002-01-01

    The electroplating of zinc is carried out in the presence of 3,4,5-Trimethoxy benzaldehyde from a chloride bath. The bath constituents are optimized through Hull cell experiments. Operating parameters such as pH, temperature, and current density are also optimized. The current efficiency and throwing power are measured at different current densities. Polarization study is carried out under galvanostatic conditions. Corrosion resistance test indicated good protection of steel by the ...

  16. Electrochemical behaviours of scandium in chloride melts

    International Nuclear Information System (INIS)

    Electrochemical behaviour of scandium(3) ions in an eutectic melt of NaCl-KCl-CsCl at 810-850 K is studied by cyclic voltammetry and chronoamperometry. The process of cathodic reduction of scandium complex ions in chloride melts is found to proceed according to the scheme: Sc(3) → Sc(0) and to be controlled by the rate of ScCl63- complex dissociation

  17. (tert-Butyl(2-hydroxyethylammonium chloride

    Directory of Open Access Journals (Sweden)

    Cintya Valerio-Cárdenas

    2014-07-01

    Full Text Available In the cation of the title molecular salt, C6H16NO+·Cl−, the N—C—C—O torsion angle is 176.5 (2°. In the crystal, the cations and chloride ions are linked by N—H...O and O—H...O hydrogen bonds, generating a two-dimensional network parallel to (100.

  18. Manganese laser using manganese chloride as lasant

    Science.gov (United States)

    Chen, C. J.

    1974-01-01

    A manganese vapor laser utilizing manganese chloride as a lasant has been observed and investigated. Lasing is attained by means of two consecutive electrical discharges. The maximum laser output is obtained at a vapor pressure of about 3 torr, a temperature of 680 C, and a time delay between electrical discharges of 150 microsec. The maximum energy density is 1.3 microjoule per cu cm.

  19. Results from the Bo Liquid Argon Scintillation Test Stand at Fermilab

    International Nuclear Information System (INIS)

    In these proceedings I discuss results from the Bo test stand at the Proton Assembly Building, Fermilab. This test stand has been used to characterize elements of the MicroBooNE optical system as well as to perform studies of processes affecting argon scintillation light such as scintillation quenching and optical absorption by impurities. I review in detail a recent measurement of the absorption of liquid argon scintillation light by dissolved nitrogen at the part-per-million level

  20. Effects of uranium bombardment by 20-40 KeV argon ions, Annex 2

    International Nuclear Information System (INIS)

    This paper shows the results of argon ions interaction with the polycrystal natural uranium. Thin foil of uranium about 200 μ was bombarded by 20-40 KeV argon ions. Coefficients of cathode scattering δ and secondary electrons emission γ were measured, during the process A+ →U. The foil was then studied by transmission method and method of single step replica using an electron microscope

  1. Effect of Ginkgo biloba on the lesions induced by retinal argon laser photocoagulation in rabbits

    International Nuclear Information System (INIS)

    In rabbits, retinal argon laser photocoagulation disrupts the arrangement of cell layers and produces interstitial edema. Photochemical and thermal energy is released with production of free oxygenated radicals that are responsible for destruction of cell membranes. Retinal argon laser photocoagulation in rabbits was used as a pharmacologic model to evaluate the protective effect of EGB 761 against membrane lesions and edema. As a strong free radicals scavengers, EGB 761 confirms its protective action on cells membranes and its anti-edema effect

  2. The clock and control system for the ATLAS Liquid Argon Calorimeter Phase-I upgrade

    International Nuclear Information System (INIS)

    A Liquid-argon Trigger Digitizer Board (LTDB) is being developed to upgrade the ATLAS Liquid Argon Calorimeter Phase-I trigger electronics. The LTDB located at the front end needs to obtain the clock signals and be configured and monitored remotely from the back end. A clock and control system is being developed for the LTDB and the major functions of the system have been evaluated. The design and evaluation of the clock and control system are presented in this paper

  3. Benchmarking TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    OpenAIRE

    Baptista, B.; Bugel, L.; Chiu, C; Conrad, J. M.; Ignarra, C. M.; Jones, B. J. P.; Katori, T.; Mufson, S.

    2012-01-01

    Scintillation light from liquid argon is produced at 128 nm and thus must be shifted to visible wavelengths in light detection systems used for Liquid Argon Time Projection Chambers (LArTPCs). To date, designs have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we show that the response of lightguides coated with TPB in a UV Transmitting (UV...

  4. TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    CERN Document Server

    Ignarra, C M

    2013-01-01

    Light detection systems in Liquid Argon Time Projection Chambers (LArTPCs) require the detection of the 128 nm light produced during argon scintillation. Most detectors use Tetraphenyl Butadiene (TPB) to shift the wavelength of the light into a range visible to Photomultiplier Tubes (PMTs). These proceedings summarize characterizations of light-guides coated with a matrix of TPB in UV transmitting acrylic which are more compact than existing LArTPC light collection systems.

  5. TPB-coated light guides for liquid argon TPC light detection systems

    Science.gov (United States)

    Ignarra, C. M.

    2013-10-01

    Light detection systems in Liquid Argon Time Projection Chambers (LArTPCs) require the detection of the 128 nm light produced during argon scintillation. Most detectors use Tetraphenyl Butadiene (TPB) to shift the wavelength of the light into a range visible to Photomultiplier Tubes (PMTs). These proceedings summarize characterizations of light-guides coated with a matrix of TPB in UV transmitting acrylic which are more compact than existing LArTPC light collection systems.

  6. Energy resolution for alpha particles in liquid argon doped with allene

    International Nuclear Information System (INIS)

    The charge response of liquid argon doped with small quantities of allene (C3H4) to α-particles has been studied. The addition of allene increased the amount of collected charge through photoionization and greatly improved the energy resolution of the incident α-particles. The noise subtracted resolution was 1.4% FWHM at the best with 4 ppm allene doped liquid argon. (orig.)

  7. Effect of Ginkgo biloba on the lesions induced by retinal argon laser photocoagulation in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Clairambault, P.; Pairault, C.; Droy-Lefaix, M.T.; Magnier, B.; Magnier, M.

    1986-01-09

    In rabbits, retinal argon laser photocoagulation disrupts the arrangement of cell layers and produces interstitial edema. Photochemical and thermal energy is released with production of free oxygenated radicals that are responsible for destruction of cell membranes. Retinal argon laser photocoagulation in rabbits was used as a pharmacologic model to evaluate the protective effect of EGB 761 against membrane lesions and edema. As a strong free radicals scavengers, EGB 761 confirms its protective action on cells membranes and its anti-edema effect.

  8. A correction to Birks' Law in liquid argon ionization chamber simulations for highly ionizing particles

    International Nuclear Information System (INIS)

    We present a study of the performance of Birks' Law in liquid argon ionization chamber simulations as applied to highly ionizing particles, such as particles with multiple electric charges or with magnetic charge. We used Birks' Law to model recombination effects in a GEANT4 simulation of heavy ions in a liquid argon calorimeter. We then compared the simulation to published heavy-ion data to extract a highly ionizing particle correction to Birks' Law.

  9. An experimental investigation of the dissociative ionization process of argon cluster ions induced by electron impact

    International Nuclear Information System (INIS)

    Utilizing the Cold Target Recoil Ions Momentum Spectrometer (COLTRIMS), dissociative ionization of argon cluster was experimentally investigated by electron impact. The recoil ions produced both in the pure ionization process and the dissociative ionization channels are measured with collision energies from 100 and 1000 eV. The ratios of the dimer ions from pure ionization (Ar2P+) and the dimer ions from small cluster dissociation (Ar+2D) to the atomic argon ion (Ar+) in different stagnation pressures were obtained.

  10. Configurational Entropy,Diffusivity and Potential Energy Landscape in Liquid Argon

    Institute of Scientific and Technical Information of China (English)

    DUAN Yong-Ping; MA Cong-Xiao; LI Jia-Yun; LI Cong; WANG Dan; LI Mei-Li; SUN Min-Hua

    2009-01-01

    The configurational entropy, diffusion coefficient, dynamics and thermodynamics fragility indices of liquid argon are calculated using molecular dynamics simulations at two densities. The relationship between dynamics and thermodynamics properties is studied. The diffusion coefficient depends linearly on configurational entropy, which is consistent with the hypothesis of Adam-Gibbs. The consistence of dynamics and thermodynamics fragility indices demonstrates that dynamical behaviour is governed by thermodynamics behaviour in glass transition of liquid argon.

  11. Spectroscopic Characterization of a Radio-Frequency Argon Plasma Jet Discharge in Ambient Air

    OpenAIRE

    Cullen, Patrick; Milosavljevic, Vladimir

    2015-01-01

    This study includes a detailed experimental investigation of the spatial and temporal spectroscopic emission of an argon plasma jet discharge. The study is carried out in ambient air and quenching by inflowing air species is considered. The optical emission spectroscopy of neutral atomic spectral lines and molecular bands, over a range of plasma process parameters, is investigated. Wavelength-resolved argon optical emission profiles are used to monitor the electron energy distribution functio...

  12. LArGe: Background suppression using liquid argon (LAr) scintillation for 0$\

    CERN Document Server

    Marco, M D; Schönert, S

    2007-01-01

    Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK Heidelberg are reported. The liquid argon--germanium system (LArGe) is operated as a 4$\\pi$ anti-Compton spectrometer to suppress backgrounds in the HPGe. This R&D is carried out in the framework of the GERDA experiment which searches for 0$\

  13. Chloride Channel Myotonia: Study of Five Cases

    Directory of Open Access Journals (Sweden)

    M Ghofrani

    2002-09-01

    Full Text Available Chloride channel Myotonia is a form of channelopathy, and Myotonia is its manifestation. Myotonia may be defined as delayed relaxation of skeletal muscle after its contraction. Decreased chloride conductance across the transverse tubular system, renders the muscle membrane hyper-excitable and leads to repetitive firing, creating Myotonia. Myotonia congenital is another name for chloride channel Myotonia. Myotonia congenital appears in autosomal dominant type called Thomson disease, autosomal recessive type called Becker disease, and a type with sporadic occurrence. Symptoms appear in the first or second decade of life. Repeated muscle contraction, the so called warm up, result in resolution of the Myotonia stiffness. Muscle stiffness and hypertrophy is another finding at physical examination. In this study we report on 5 patients, which had clinical and electrical signs of Myotonia. Muscle hypertrophy and warm up phenomena were present in all cases. CPK measurement of all cases were normal. 2 patients underwent muscle biopsy that showed only atrophy and increased central nuclei. In three cases autosomal recessive inheritance (Becker, in one case autosomal dominant inheritance (Thomsen and in one case sporadic occurrence was suggested. With respect to successful results of carbamazepine therapy in 4 patients, and being excellent in one of them, we suggest carbamazepine for the first choice of Myotonia treatment.

  14. An autopsy case of zinc chloride poisoning.

    Science.gov (United States)

    Kondo, Takeshi; Takahashi, Motonori; Watanabe, Seiya; Ebina, Masatomo; Mizu, Daisuke; Ariyoshi, Koichi; Asano, Migiwa; Nagasaki, Yasushi; Ueno, Yasuhiro

    2016-07-01

    Ingestion of large amounts of zinc chloride causes corrosive gastroenteritis with vomiting, abdominal pain, and diarrhea. Some individuals experience shock after ingesting large amounts of zinc chloride, resulting in fatality. Here, we present the results of an administrative autopsy performed on a 70-year-old man who ingested zinc chloride solution and died. After drinking the solution, he developed vomiting, abdominal pain, and diarrhea, and called for an ambulance. Except for tachycardia, his vital signs were stable at presentation. However, he developed hypotension and severe metabolic acidosis and died. The patient's blood zinc concentration on arrival was high at 3030μg/dL. Liver cirrhosis with cloudy yellow ascites was observed, however, there were no clear findings of gastrointestinal perforation. The gastric mucosa was gray-brown, with sclerosis present in all gastric wall layers. Zinc staining was strongly positive in all layers. There was almost no postmortem degeneration of the gastric mucosal epithelium, and hypercontracture of the smooth muscle layer was observed. Measurement of the zinc concentration in the organs revealed the highest concentration in the gastric mucosa, followed by the pancreas and spleen. Clinically, corrosive gastroenteritis was the cause of death. However, although autopsy revealed solidification in the esophagus and gastric mucosa, there were no findings in the small or large intestine. Therefore, metabolic acidosis resulting from organ damage was the direct cause of death. PMID:27497327

  15. Potassium chloride production by microcline chlorination

    International Nuclear Information System (INIS)

    Highlights: • Use of chlorination for the KCl production. • The reagents used were microcline, hydromagnesite and chlorine. • Isothermal and non-isothermal assays were performed in Cl2–N2 mixture. • The chlorination generated KCl at 700 °C. • The chlorination products promote KCl formation. - Abstract: The potassium chloride is one of the most important fertilizers used in agriculture. The current demand of this salt makes interesting the study of potassium chloride production from unconventional potassium resources. In this work the potassium chloride production by chlorination of microcline was investigated. The starting reagents were microcline, hydromagnesite and chlorine. Non-isothermal and isothermal chlorination assays were carried out in a thermogravimetric device adapted to work in corrosive atmospheres. The temperature effect on potassium extraction and the phase transformations produced during chlorination of microcline were studied. The reagents and reaction products were analyzed by X-ray fluorescence (XRF) and X-ray diffraction (XRD). The experimental results indicated that by chlorination of microcline an important extraction of potassium in the temperature range from 800 to 900 °C was produced. Moreover, at 800 °C the forsterite, enstatite and magnesium aluminate spinel phases were generated

  16. Microwave spectrum and structure of nitrosyl chloride

    International Nuclear Information System (INIS)

    The microwave spectra of 15N isotopic species of nitrosyl chloride, 15NO35Cl and 15NO37Cl, have been assigned between 8 and 26 GHz, and the following rotational constants have been obtained: A = 81600 MHz, B = 5693.80 MHz, and C = 5322.44 MHz for 15NO35Cl, A = 81520 MHz, B = 5556.07 MHz, and C = 5201.56 MHz for 15NO37Cl. The microwave spectra of the normal species of nitrosyl chloride as well as the 37Cl species and the 18O species have already been measured by Millen et al. (1961). An analysis of both the rotational constants obtained in this study and the constants by Millen et al. has given the following bond lengths and angle as the complete r sub(s) structural parameters of nitrosyl chloride. r(N-O) = 1.143 +- 0.006 A, r(N-Cl) = 1.973 +- 0.003 A, and 0 +- 0.50. The nuclear quadrupole coupling constants in the N-Cl bond axis system of 15NO35Cl are X sub(zz) = -57.8 MHz and eta = -0.311. (author)

  17. Boldine action against the stannous chloride effect.

    Science.gov (United States)

    Reiniger, I W; Ribeiro da Silva, C; Felzenszwalb, I; de Mattos, J C; de Oliveira, J F; da Silva Dantas, F J; Bezerra, R J; Caldeira-de-Araújo, A; Bernardo-Filho, M

    1999-12-15

    Peumus boldus extract has been used in popular medicine in the treatment of biliar litiase, hepatic insufficiency and liver congestion. Its effects are associated to the substance boldine that is present in its extract. In the present work, we evaluated the influence of boldine both in: (i) the structural conformation of a plasmid pUC 9.1 through gel electrophoresis analysis; and in (ii) the survival of the strain of Escherichia coli AB1157 submitted to reactive oxygen species (ROS), generated by a Fenton like reaction, induced by stannous chloride. Our results show a reduction of the lethal effect induced by stannous chloride on the survival of the E. coli culture in the presence of boldine. The supercoiled form of the plasmid is not modified by stannous chloride in the presence of boldine. We suggest that the protection induced by boldine could be explained by its anti-oxidant mechanism. In this way, the boldine could be reacting with stannous ions, protecting them against the oxidation and, consequently, avoiding the generation of ROS. PMID:10624900

  18. Potassium chloride production by microcline chlorination

    Energy Technology Data Exchange (ETDEWEB)

    Orosco, Pablo, E-mail: porosco@unsl.edu.ar [Instituto de Investigaciones en Tecnología Química (INTEQUI), Chacabuco y Pedernera, San Luis (Argentina); Facultad de Química, Bioquímica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, San Luis (Argentina); Ruiz, María del Carmen [Instituto de Investigaciones en Tecnología Química (INTEQUI), Chacabuco y Pedernera, San Luis (Argentina)

    2015-08-10

    Highlights: • Use of chlorination for the KCl production. • The reagents used were microcline, hydromagnesite and chlorine. • Isothermal and non-isothermal assays were performed in Cl{sub 2}–N{sub 2} mixture. • The chlorination generated KCl at 700 °C. • The chlorination products promote KCl formation. - Abstract: The potassium chloride is one of the most important fertilizers used in agriculture. The current demand of this salt makes interesting the study of potassium chloride production from unconventional potassium resources. In this work the potassium chloride production by chlorination of microcline was investigated. The starting reagents were microcline, hydromagnesite and chlorine. Non-isothermal and isothermal chlorination assays were carried out in a thermogravimetric device adapted to work in corrosive atmospheres. The temperature effect on potassium extraction and the phase transformations produced during chlorination of microcline were studied. The reagents and reaction products were analyzed by X-ray fluorescence (XRF) and X-ray diffraction (XRD). The experimental results indicated that by chlorination of microcline an important extraction of potassium in the temperature range from 800 to 900 °C was produced. Moreover, at 800 °C the forsterite, enstatite and magnesium aluminate spinel phases were generated.

  19. Solubility of sodium chloride in superheated steam

    International Nuclear Information System (INIS)

    The solubility of sodium chloride in superheated steam was investigated in laboratory-scale experiments up to 20 MPa and 475 C. These experiments were carried out using a dynamic method where deionized steam was passed through a packed bed of salt crystals in a 500 mL Hastelloy autoclave. The residence time of the steam in the salt bed was sufficient to saturate the steam with the salt. The steam samples were cooled and analyzed by ion chromatography. Correlations based on temperature and density were selected to describe the solubility of sodium chloride in superheated steam. The density dependence is much stronger than the temperature dependence. By using these correlations, it is possible to estimate the solubility of salt in steam at lower densities than those used in the experiments. Enthalpy-entropy diagrams are given that show the steam expansion line in turbines, including curves for constant concentration of sodium chloride solubility in steam. These can be used to analyze where in the steam cycle this salt may deposit. (orig.)

  20. Discovery of photospheric argon in very hot central stars of planetary nebulae and white dwarfs

    CERN Document Server

    Werner, K; Kruk, J W

    2007-01-01

    We report the first discovery of argon in hot evolved stars and white dwarfs. We have identified the ArVII 1063.55A line in some of the hottest known (Teff=95000-110000 K) central stars of planetary nebulae and (pre-) white dwarfs of various spectral type. We determine the argon abundance and compare it to theoretical predictions from stellar evolution theory as well as from diffusion calculations. We analyze high-resolution spectra taken with the Far Ultraviolet Spectroscopic Explorer. We use non-LTE line-blanketed model atmospheres and perform line-formation calculations to compute synthetic argon line profiles. We find a solar argon abundance in the H-rich central star NGC1360 and in the H-deficient PG1159 star PG1424+535. This confirms stellar evolution modeling that predicts that the argon abundance remains almost unaffected by nucleosynthesis. For the DAO-type central star NGC7293 and the hot DA white dwarfs PG0948+534 and REJ1738+669 we find argon abundances that are up to three orders of magnitude sma...

  1. Numerical study of breakdown pattern induced by an intense microwave under nitrogen and argon gases

    Science.gov (United States)

    Takahashi, Masayuki; Ohnishi, Naofumi

    2016-07-01

    Filamentary plasma induced by microwave beam irradiation was reproduced in nitrogen and argon by combining fluid or particle plasma models with electromagnetic wave propagation. Transport coefficients used in the fluid model are estimated from particle simulation to maintain consistency of the breakdown structure between the fluid and particle models. A discrete structure was obtained using the one-dimensional (1D) fluid model, because a standing wave is generated in front of the plasma when the incident microwave beam is reflected by the overcritical plasma, which agrees with the breakdown structure obtained using the 1D particle model. A 2D plasma filament was also reproduced using the fluid model in nitrogen and argon. Reflection of the incident microwave in argon becomes stronger than that in nitrogen because of the denser argon plasma. Change in filament shape is induced in argon because the electric field is deformed at the plasma tip owing to stronger wave reflection from the neighboring filament. The propagation speed of the plasma front becomes larger in argon breakdown because of the larger ionization frequency and the larger diffusion coefficient.

  2. Effect of Argon Laser on Enamel Demineralization around Orthodontic Brackets: An In Vitro Study

    Science.gov (United States)

    Miresmaeili, Amirfarhang; Etrati Khosroshahi, Mohammad; Motahary, Pouya; Rezaei-Soufi, Loghman; Mahjub, Hossein; Dadashi, Maryam; Farhadian, Nasrin

    2014-01-01

    Objective This study was designed to evaluate the effect of argon laser irradiation on development and progress of enamel demineralization around orthodontic brackets. Materials and Methods: Fifty caries-free, intact human premolars were randomly assigned to one of the following five equal groups: Groups 1 (control) and 2: The brackets were bonded using conventional halogen light for 40s and argon laser for 10s, respectively. Teeth in group 3 were lased with argon laser for 10s before bracket bonding with halogen light. Group 4 was the same as group 3 except that brackets were also bonded with argon laser. In group 5 samples were bonded conventionally, immersed in an artificial caries solution for two days and then irradiated for 10s with argon laser. All samples were subjected to demineralization by artificial caries solution for 10 days. After bracket removal, samples were buccolingually sectioned and evaluated by polarized light microscopy. Decalcified lesion depth in each section was measured by a trained examiner in a blind fashion. Data were analyzed in SPSS 14 using one-way ANOVA and Tukey’s HSD post hoc test. Results: The control group showed the greatest mean lesion depth while group 5 revealed the lowest. The laser-treated groups had significantly lower mean lesion depth compared with the control group (P<0.05) except for group 4 (P=0.192). Conclusion: Argon laser irradiation for 10s before or during bracket bonding can increase caries resistance of intact and demineralized enamel. PMID:25584052

  3. Low radioactivity argon dark matter search results from the DarkSide-50 experiment

    CERN Document Server

    Agnes, P; Albuquerque, I F M; Alexander, T; Alton, A K; Arisaka, K; Back, H O; Baldin, B; Biery, K; Bonfini, G; Bossa, M; Bottino, B; Brigatti, A; Brodsky, J; Budano, F; Bussino, S; Cadeddu, M; Cadonati, L; Cadoni, M; Calaprice, F; Canci, N; Candela, A; Cao, H; Cariello, M; Carlini, M; Catalanotti, S; Cavalcante, P; Chepurnov, A; Cocco, A G; Covone, G; Crippa, L; D'Angelo, D; D'Incecco, M; Davini, S; De Cecco, S; De Deo, M; De Vincenzi, M; Derbin, A; Devoto, 25 A; Di Eusanio, F; Di Pietro, G; Edkins, E; Empl, A; Fan, A; Fiorillo, G; Fomenko, K; Forster, G; Franco, D; Gabriele, F; Galbiati, C; Giganti, C; Goretti, A M; Granato, F; Grandi, L; Gromov, M; Guan, M; Guardincerri, Y; Hackett, B R; Herner, K; Hungerford, E V; Ianni, Al; Ianni, An; James, I; Jollet, C; Keeter, K; Kendziora, C L; Kobychev, V; Koh, G; Korablev, D; Korga, G; Kubankin, A; Li, X; Lissia, M; Lombardi, P; Luitz, S; Ma, Y; Machulin, I N; Mandarano, A; Mari, S M; Maricic, J; Marini, L; Martoff, C J; Meregaglia, A; Meyers, P D; Miletic, T; Milincic, R; Montanari, D; Monte, A; Montuschi, M; Monzani, M; Mosteiro, P; Mount, B J; Muratova, V N; Musico, P; Napolitano, J; Nelson, A; Odrowski, S; Orsini, M; Ortica, F; Pagani, L; Pallavicini, M; Pantic, E; Parmeggiano, S; Pelczar, K; Pelliccia, N; Perasso, S; Pocar, A; Pordes, S; Pugachev, D A; Qian, H; Randle, K; Ranucci, G; Razeto, A; Reinhold, B; Renshaw, A L; Romani, A; Rossi, B; Rossi, N; Rountree, D; Sablone, D; Saggese, P; Saldanha, R; Sands, W; Sangiorgio, S; Savarese, C; Segreto, E; Semenov, D A; Shields, E; Singh, P N; Skorokhvatov, M D; Smallcomb, M; Smirnov, O; Sotnikov, A; Stanford, C; Suvorov, Y; Tartaglia, R; Tatarowicz, J; Testera, G; Tonazzo, A; Trinchese, P; Unzhakov, E V; Vishneva, A; Vogelaar, B; Wada, M; Walker, S; Wang, H; Wang, Y; Watson, A W; Westerdale, S; Wilhelmi, J; Wojcik, M M; Xiang, X; Xu, J; Yang, C; Yoo, J; Zavatarelli, S; Zec, A; Zhong, W; Zhu, C; Zuzel, G

    2015-01-01

    The DarkSide-50 dark matter search reports the first results obtained using a target of low-radioactivity argon extracted from underground sources. The experiment is located at the Laboratori Nazionali del Gran Sasso and uses a two-phase time projection chamber as a detector. A total of 155 kg of low radioactivity argon has been obtained, and we have determined that underground argon is depleted in Ar-39 by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. The underground argon was also found to contain (2.05 +- 0.13) mBq/kg of Kr-85. We found no evidence for dark matter in the form of WIMPs in 70.9 live-days of data with a fiducial mass of (36.9 +- 0.6) kg. When combined with our preceding search with an atmospheric argon target, we set a 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2 ) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2 ).

  4. Surface treatment of para-aramid fiber by argon dielectric barrier discharge plasma at atmospheric pressure

    International Nuclear Information System (INIS)

    Highlights: ► We use DBD technique to modify the surface of Kelvar29 fibers. ► The changed parameters include treated power, time and argon flux. ► There exists an optimum experimental condition of plasma treatment. ► Adhesion and wettability properties of fibers are improved through plasma treatment. - Abstract: This paper is focused on influence of argon dielectric barrier discharge (DBD) plasma on the adhesive performance and wettability of para-aramid fibers and three parameters including treated power, exposure time and argon flux were detected. The interfacial shear strength (IFSS) was greatly increased by 28% with 300 W, 60 s, 2 L min−1 argon flux plasma treatment. The content of oxygen atom and oxygen-containing polar functional groups were enhanced after the argon plasma treated, so as the surface roughness, which contributed to the improvement of surface wettability and the decrease of contact angle with water. However, long-time exposure, exorbitant power or overlarge argon flux could partly destroy the prior effects of the treatment and damage the mechanical properties of fibers to some degree.

  5. Results from the first use of low radioactivity argon in a dark matter search

    Science.gov (United States)

    Agnes, P.; Agostino, L.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Arisaka, K.; Back, H. O.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadonati, L.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cocco, A. G.; Covone, G.; Crippa, L.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Vincenzi, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giganti, C.; Goretti, A. M.; Granato, F.; Grandi, L.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; James, I.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Lombardi, P.; Luitz, S.; Ma, Y.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Miletic, T.; Milincic, R.; Montanari, D.; Monte, A.; Montuschi, M.; Monzani, M.; Mosteiro, P.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Nelson, A.; Odrowski, S.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Perasso, S.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Savarese, C.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Vishneva, A.; Vogelaar, B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wilhelmi, J.; Wojcik, M. M.; Xiang, X.; Xu, J.; Yang, C.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhong, W.; Zhu, C.; Zuzel, G.; DarkSide Collaboration

    2016-04-01

    Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using a two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain 39Ar at a level reduced by a factor (1.4 ±0.2 )×103 relative to atmospheric argon. We report a background-free null result from (2616 ±43 ) kg d of data, accumulated over 70.9 live days. When combined with our previous search using an atmospheric argon, the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section, based on zero events found in the WIMP search regions, is 2.0 ×10-44 cm2 (8.6 ×10-44 cm2 , 8.0 ×10-43 cm2 ) for a WIMP mass of 100 GeV /c2 (1 TeV /c2 , 10 TeV /c2 ).

  6. Results from the first use of low radioactivity argon in a dark matter search

    Energy Technology Data Exchange (ETDEWEB)

    Agnes, P. [Universite Paris Diderot (France). et al.

    2016-04-08

    Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 103 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10-44 cm2 (8.6 x 10-44 cm2, 8.0 x 10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2 , 10 TeV/c2).

  7. The Accelerated Test of Chloride Permeability of Concrete

    Institute of Scientific and Technical Information of China (English)

    TAN Ke-feng; ODD E Gjφrv

    2003-01-01

    The availability of accelerated chloride permeability test and the effect of w/c ratio, incorporation of silica fume, maximum aggregate size and aggregate type on the chloride permeability were studied. The mathematic analysis certifies that there is a linear relationship between accelerated test and natural diffusion. Test results show that the chloride permeability of concrete increases as w/c ratio increases whilst a limited amount of replacement of cement with silica fume, the chloride permeability decreases dramatically. The maximum aggregate size in the range of 8 to 25 mm seems also affect chloride permeability but with a much less significant level. The chloride permeability of silica fume lightweight aggregate concrete is very low, especially the concrete made with dry lightweight concrete. The chloride permeability can be evaluated by this accelerated test method.

  8. Relation between chloride exchange diffusion and a conductive chloride pathway across the isolated skin of the toad (Bufo bufo)

    DEFF Research Database (Denmark)

    Kristensen, P; Larsen, Erik Hviid

    1978-01-01

    Substitution of chloride in the outside bathing medium of the toad skin with bromide, iodide, nitrate and sulphate leads to a reduction in the apparent exchange diffusion of chloride across this tissue, and also to a reduction of the chloride current recorded during hyperpolarization. A series of...... systems could be explained as secondary effects due to a primary interaction with the sodium transport mechanisms. A correlation was found between the clamping current recorded during hyperpolarization and the efflux of chloride under short circuit conditions with chloride Ringer's on both sides. On the...

  9. Scintillation light from cosmic-ray muons in liquid argon

    Science.gov (United States)

    Whittington, D.; Mufson, S.; Howard, B.

    2016-05-01

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a composite model. Both models find τT = 1.52 μs for the decay time constant of the Ar2* triplet state. These models also show that the identification of the ``early'' light fraction in the phenomenological model, FE ≈ 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS ≈ 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value ~0.3 found by dark matter and double β-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  10. Argon-ion charge distributions following near-threshold ionization

    International Nuclear Information System (INIS)

    When an atom is photoionized in an inner shell, there are two mechanisms by which the remaining electron cortege relaxes to fill the vacancy: x-ray emission and radiationless Auger and Coster-Kronig transitions. In the former, the inner-shell hole moves to a less tightly bound orbital without increasing the number of atomic vacancies. In Auger processes, however, the energy liberated by transfer of a less-tightly-bound electron to the inner-shell vacancy is transferred to another electron which is ejected into the continuum. In this case, the charge on the residual ion increases by one. Through a series of radiative and non-radiative processes, the initial vacancy bubbles up until all vacancies arrive at the outermost shell. Due to the many possible routes by which this may occur, there can be a broad distribution of residual ion charge states characteristic of the decay of a single inner-shell vacancy. Because so many processes can contribute to each charge state, it is difficult to determine the effect of each by examining the total ion charge distribution; the total-ion charge distribution represents an average over many effects. To overcome this limitation, the author has recently measured argon-ion production as a function of both photon energy and Auger decay channel following photoionization of K-shell electrons with highly monochromatic synchrotron radiation. When measured differential in decay channel, the ion charge distributions are greatly simplified. Analysis, in progress, of these simplified distributions will permit extraction of information about relative decay rates and shakeoff effects that is obscured in the single spectra

  11. Scintillation light from cosmic-ray muons in liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Whittington, Denver Wade [Indiana Univ., Bloomington, IN (United States). Physics Dept.; Mufson, S. [Indiana Univ., Bloomington, IN (United States). Astronomy Dept.; Howard, B. [Indiana Univ., Bloomington, IN (United States). Physics Dept.

    2016-05-01

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a physically-motivated model. Both models find tT = 1:52 ms for the decay time constant of the Ar 2 triplet state. These models also show that the identification of the “early” light fraction in the phenomenological model, FE 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value 0.3 found by dark matter and double b-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  12. Imaging of hydrogen halides photochemistry on argon and ice nanoparticles.

    Science.gov (United States)

    Poterya, V; Lengyel, J; Pysanenko, A; Svrčková, P; Fárník, M

    2014-08-21

    The photodissociation dynamics of HX (X = Cl, Br) molecules deposited on large ArN and (H2O)N, N̄ ≈ 10(2)-10(3), clusters is investigated at 193 nm using velocity map imaging of H and Cl photofragments. In addition, time-of-flight mass spectrometry after electron ionization complemented by pickup cross section measurements provide information about the composition and structure of the clusters. The hydrogen halides coagulate efficiently to generate smaller (HX)n clusters on ArN upon multiple pickup conditions. This implies a high mobility of HX molecules on argon. On the other hand, the molecules remain isolated on (H2O)N. The photodissociation on ArN leads to strong H-fragment caging manifested by the fragment intensity peaking sharply at zero kinetic energy. Some of the Cl-fragments from HCl photodissociation on ArN are also caged, while some of the fragments escape the cluster directly without losing their kinetic energy. The images of H-fragments from HX on (H2O)N also exhibit a strong central intensity, however, with a different kinetic energy distribution which originates from different processes: the HX acidic dissociation followed by H3O neutral hydronium radical formation after the UV excitation, and the slow H-fragments stem from subsequent decay of the H3O. The corresponding Cl-cofragment from the photoexcitation of the HCl·(H2O)N is trapped in the ice nanoparticle. PMID:25149788

  13. Modelling steel’s homogenization during argon purging

    Directory of Open Access Journals (Sweden)

    J. Pieprzyca

    2012-12-01

    Full Text Available Purpose: One of the primary tasks that put the steel producers to the test is to reduce production costs while maintaining high quality. This objective is achieved among others through the optimization of conducted technological processes. Commonly used technology of steel homogenization with inert gases is an important stage in the production of steel in which that objective can be accomplished.Design/methodology/approach: Tests of hydrodynamic processes occurring during the steel blowing with inert gases process directly in industrial conditions is very difficult or impossible. Therefore, as the primary research method physical modelling was used. In order to carry out the tests described in the article a physical model of the station for the argon purging was used that is working at the VSB-TU, Department of Metallurgy and Foundry in Ostrava.Findings: As a result the study provided values for the investigated process and determined the appropriate location of the gas-permeable fittings in steelmaking ladle’s bottom plug. This allows to obtain the required conditions for the steel mixing in the entire volume of ladle’s workspace.Research limitations/implications: Tests presented in the article were carried out in the VSB-TU in Ostrava. Due to this fact some research limitations occurs that applies to localization and physical model’s specific construction. Therefore, as a result of cooperation between VSB-TU in Ostrava and the Silesian University of Technology will be carried out the construction of the new research station in Katowice.Practical implications: The results of the research constitute the basis to make changes that will allow the optimization to so far used purge of steel technology.Originality/value: The results presented in the article are addressed to the steel producers and it allows to optimize on-going steel homogenization process that takes place in the ladle

  14. Argon entrainment into liquid sodium in fast breeder reactor

    International Nuclear Information System (INIS)

    Highlights: ► In the present work, different types of entrainment mechanisms have been studied. ► Onset of entrainment could be characterized with turbulent intensities. ► For vortex type entrainment, a correlation has been proposed. - Abstract: Gas entrainment in pool type sodium cooled fast breeder reactors has been a subject of great interest for a quite long time now. The issue of entrainment of argon cover gas in LMFBR's is being addressed by fundamental studies. Present work focuses on characterization of onset of shear type entrainment and liquid fall type entrainment based on mean velocity and turbulent kinetic energy at liquid surface. Study also includes characterization of onset of vortex type entrainment based on mean velocities (time averaged) in the outlet pipe. Experiments were carried out to characterize shear type entrainment in stirred tank with different impeller geometries with air–water and xylene–water systems. Onset of liquid fall type entrainment was studied with cylindrical tank with a nozzle whose input angle varied. Mean and r.m.s. velocity profiles near the liquid surface were measured with the help of ultrasonic velocity profiler (UVP). The results are compared with other literature. It is observed that the onset of entrainment can be characterized by the turbulent kinetic energy near the free liquid surface. Re-submergence angle was measured and r.m.s. velocities found to be in the same range as in case of shear type of entrainment. Cylindrical tank with tangential inlet and bottom outlet was used to study onset of vortex formation. Effect of different parameters like outlet diameter, tank diameter and liquid height in the tank on critical velocity was studied and correlation has been proposed.

  15. Inhaled 45–50% argon augments hypothermic brain protection in a piglet model of perinatal asphyxia

    Science.gov (United States)

    Broad, Kevin D.; Fierens, Igor; Fleiss, Bobbi; Rocha-Ferreira, Eridan; Ezzati, Mojgan; Hassell, Jane; Alonso-Alconada, Daniel; Bainbridge, Alan; Kawano, Go; Ma, Daqing; Tachtsidis, Ilias; Gressens, Pierre; Golay, Xavier; Sanders, Robert D.; Robertson, Nicola J.

    2016-01-01

    Cooling to 33.5 °C in babies with neonatal encephalopathy significantly reduces death and disability, however additional therapies are needed to maximize brain protection. Following hypoxia–ischemia we assessed whether inhaled 45–50% Argon from 2–26 h augmented hypothermia neuroprotection in a neonatal piglet model, using MRS and aEEG, which predict outcome in babies with neonatal encephalopathy, and immunohistochemistry. Following cerebral hypoxia–ischemia, 20 Newborn male Large White piglets < 40 h were randomized to: (i) Cooling (33 °C) from 2–26 h (n = 10); or (ii) Cooling and inhaled 45–50% Argon (Cooling + Argon) from 2–26 h (n = 8). Whole-brain phosphorus-31 and regional proton MRS were acquired at baseline, 24 and 48 h after hypoxia–ischemia. EEG was monitored. At 48 h after hypoxia–ischemia, cell death (TUNEL) was evaluated over 7 brain regions. There were no differences in body weight, duration of hypoxia–ischemia or insult severity; throughout the study there were no differences in heart rate, arterial blood pressure, blood biochemistry and inotrope support. Two piglets in the Cooling + Argon group were excluded. Comparing Cooling + Argon with Cooling there was preservation of whole-brain MRS ATP and PCr/Pi at 48 h after hypoxia–ischemia (p < 0.001 for both) and lower 1H MRS lactate/N acetyl aspartate in white (p = 0.03 and 0.04) but not gray matter at 24 and 48 h. EEG background recovery was faster (p < 0.01) with Cooling + Argon. An overall difference between average cell-death of Cooling versus Cooling + Argon was observed (p < 0.01); estimated cells per mm2 were 23.9 points lower (95% C.I. 7.3–40.5) for the Cooling + Argon versus Cooling. Inhaled 45–50% Argon from 2–26 h augmented hypothermic protection at 48 h after hypoxia–ischemia shown by improved brain energy metabolism on MRS, faster EEG recovery and reduced cell death on TUNEL. Argon may provide a cheap and practical therapy

  16. Influence of Additive Gas on Electrical and Optical Characteristics of Non-equilibrium Atmospheric Pressure Argon Plasma Jet

    International Nuclear Information System (INIS)

    Electrical and optical properties of an argon plasma jet were characterized. In particular, effects of an additive gas, namely nitrogen or oxygen, on these properties were studied in detail. The plasma jet was found to be of a glow-like discharge, which scarcely changed upon the injection of an additive gas, either directly or through a glass capillary. Optical emission spectroscopy characterization revealed that excited argon atoms were the predominant active species in this plasma jet. Metastable argon atoms were highly quenched, and N2(C3Πu) became the main energy carrier following nitrogen injection. When oxygen was added to the afterglow zone through a glass capillary, no significant quenching effect was observed and the number of oxygen atoms decreased with the increase in oxygen concentration. Finally, to demonstrate an application of this plasma jet, a high-density polyethylene surface was treated with argon, argon/nitrogen, and argon/oxygen plasmas.

  17. Molecular mechanisms of carcinogenesis by vinyl chloride.

    Science.gov (United States)

    Dogliotti, Eugenia

    2006-01-01

    In 1974 vinyl chloride (VC), a gas used in the plastics industry, was shown to be a human carcinogen, inducing a very rare type of tumor, angiosarcoma of the liver. The same type of tumor was induced in rodents exposed to VC thus providing an excellent model for mechanistic studies. Here, we review the numerous studies on the mechanism of action of VC with particular emphasis on the DNA products induced by this strong alkylating agent. In particular, the genotoxicity, repair mechanisms, in vivo formation and tumor mutation spectra by etheno-adducts will be analysed and possible approaches for future research suggested. PMID:17033136

  18. Solidification of supercooled molten zinc chloride

    Czech Academy of Sciences Publication Activity Database

    Rodová, Miroslava; Cihlář, Antonín; Nitsch, Karel

    Bratislava: x, 2005 - (Koman, M.; Mikloš, D.), s. 5-9 ISBN 80-89088-42-2. [Development of Materials Science in Research and Education - DMS -RE 2005 /15./. Kežmarské Žĺaby (SK), 05.09.2005-09.09.2005] R&D Projects: GA ČR(CZ) GA202/03/0428 Institutional research plan: CEZ:AV0Z10100521 Keywords : molten zinc chloride * thermal analysis * crystallization * glass formation Subject RIV: BM - Solid Matter Physics ; Magnetism

  19. Benzalkonium Chloride Intoxication Mimicking Herpes Zoster Encephalitis

    Directory of Open Access Journals (Sweden)

    Ekrem Güler

    2011-06-01

    Full Text Available Benzalkonium chloride (BAC is a frequently used disinfectant and its most well-known side effect is contact dermatitis. In this report, two children who had vesicular dermatitis, headache, lethargy, fever and encephalopathy mimicking Herpes zoster encephalitis were presented. Their consciousness level improved on the second day. From the medical history it was understood that the mother had applied 20% BAC solution to the scalps of two children. The aim of the presentation of this report is to draw attention to the fact that BAC application to the scalp for treating pediculosis capitis may resemble the herpes encephalitis clinical picture.

  20. The excitation structure in a micro-hollow cathode discharge in the normal regime at medium argon pressure

    OpenAIRE

    C. Lazzaroni; Chabert, P.; A. Rousseau(MSSL, Surrey, United Kingdom); Sadeghi, N.

    2010-01-01

    Abstract A microplasma is generated in the microhole (400 ?m diameter) of a molybdenum-aluminamolybdenum sandwich (MHCD type) at medium pressure (30-200 Torr) in pure argon. Imaging and emission spectroscopy have been used to study the light emission mechanisms in the microdischarge. We find that emission intensities of both argon atom and argon ion lines present sharp peaks located near the cathode, and that the position of these peaks moves toward the cathode with increasing gas pressure...

  1. Preparation of the first electrolytic plutonium and of uranium from fused chlorides

    International Nuclear Information System (INIS)

    The production at Los Alamos of the first electrolytic plutonium is described. Because it was scarce, it was initially prepared on a 50 mg scale. The electrolyte consisted of PuCl3 dissolved in a ternary eutectic o BaCl2-KCl-NaCl and was operated at 6600C. The technique involved the electrolysis of as little as 0.1 cm3 of fused salt in a glass cell to produce liquid metal. Subsequently, a few successful 1g electrolyses were carried out with a maximum recovery of 75% of the plutonium content of the bath. It was found that the plutonium trichloride had to be dry and relatively low in oxygen and was, therefore, best prepared by dry methods. Electrolyses were performed under purified argon or hydrogen using tungsten or graphite anodes. The metallic product was pure and was used for early development of methods for cleaning, etching, and plating plutonium. Uranium was used for finding and testing techniques before plutonium became available. Acceptable deposits could not be obtained from UCl4 dissolved in the ternary chloride eutectic, but were produced when UCl3 was substituted for the tetrachloride. At about 6500C, the uranium was deposited in the form of solid, dendriti crystals. These were, in general purer than the starting materials and were readily converted to massive metal

  2. Chloride regulates afferent arteriolar contraction in response to depolarization

    DEFF Research Database (Denmark)

    Hansen, P B; Jensen, B L; Skott, O

    1998-01-01

    afferent arterioles. In 70% of vessels examined, K+-induced contraction was abolished by acute substitution of bath chloride. Consecutive addition of Cl- (30, 60, 80, 100, 110, and 117 mmol/L) restored the sensitivity to K+, and half-maximal response was observed at 82 mmol/L chloride. The calcium channel...... results show that K+-induced contraction of smooth muscle cells in the afferent arteriole is highly sensitive to chloride, whereas neurotransmitter release and ensuing contraction is not dependent on chloride. Thus, there are different activation pathways for depolarizing vasoconstrictors and for the......-Renal vascular reactivity is influenced by the level of dietary salt intake. Recent in vitro data suggest that afferent arteriolar contractility is modulated by extracellular chloride. In the present study, we assessed the influence of chloride on K+-induced contraction in isolated perfused rabbit...

  3. Chloride Ingress in Concrete Cracks under Cyclic Loading

    DEFF Research Database (Denmark)

    Küter, André; Geiker, Mette Rica; Olesen, John Forbes;

    2005-01-01

    increasing focus on the need for modeling the ingress of chloride into cracked concrete. Present models quantify chloride ingress in static cracks only, although several structural applications display dynamic loading conditions in an environment containing chlorides, e.g. marine structures and car parks....... Preliminary investigations have been undertaken to quantify the effect of dynamic load application on the chloride ingress into concrete cracks. Specimens were designed allowing ingress of a chloride solution into a single crack of a saturated unreinforced mortar beam. One set of specimens was subjected to a...... load frequency of ten applications per minute and a second set to one application per hour simulating static cracks, however limiting the ingress hampering effects of autogenous healing and a possible dense precipitation on the crack faces. The averaged chloride exposure interval of the crack faces was...

  4. Anodic Behavior of Alloy 22 in Calcium Chloride and in Calcium Chloride Plus Calcium Nitrate Brines

    Energy Technology Data Exchange (ETDEWEB)

    Evans, K J; Day, S D; Ilevbare, G O; Whalen, M T; King, K J; Hust, G A; Wong, L L; Estill, J C; Rebak, R B

    2003-05-13

    Alloy 22 (UNS N60622) is a nickel-based alloy, which is extensively used in aggressive industrial applications, especially due to its resistance to localized corrosion and stress corrosion cracking in high chloride environments. The purpose of this work was to characterize the anodic behavior of Alloy 22 in concentrated calcium chloride (CaCl{sub 2}) brines and to evaluate the inhibitive effect of nitrate, especially to localized corrosion. Standard electrochemical tests such as polarization resistance and cyclic polarization were used. Results show that the corrosion potential of Alloy 22 was approximately -360 mV in the silver-silver chloride (SSC) scale and independent of the tested temperature. Cyclic polarization tests showed that Alloy 22 was mainly susceptible to localized attack in 5 M CaCl{sub 2} at 75 C and higher temperatures. The addition of nitrate in a molar ratio of chloride to nitrate equal to 10 increased the onset of localized corrosion to approximately 105 C. The addition of nitrate to the solution also decreased the uniform corrosion rate and the passive current of the alloy.

  5. Argon gas concentration effects on nanostructured molybdenum nitride layer growth using 100 Hz pulsed dc glow discharge

    Science.gov (United States)

    Ikhlaq, U.; Ahmad, R.; Saleem, S.; Shah, M. S.; Umm-i-Kalsoom; Khan, N.; Khalid, N.

    2012-08-01

    The effect of argon concentration (10%-40%) on the surface properties of molybdenum is studied in nitrogen-argon mixture using 100 Hz pulsed dc glow discharge. The analysis is carried out by using X-ray diffractometer (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and Vickers microhardness tester to investigate surface properties of the nitrided samples. XRD results exhibit the formation of molybdenum nitrides. Crystallite size analysis and SEM morphology confirm the growth of nanostructured molybdenum nitride layers. Moreover, significant increase in surface hardness (by a factor of about two times) is found when the sample is treated for 30% argon in nitrogen-argon mixed plasma.

  6. Interactions between chloride ingress and carbonation in cementitious materials

    OpenAIRE

    SAILLIO, Mickael; BARBERON, Fabien; BAROGHEL BOUNY, Véronique; GEGOUT, Philippe; PLATRET, Gérard; D'ESPINOSE DE LA CAILLERIE, JB

    2011-01-01

    Carbonation and chloride attacks are the major causes of reinforced concrete (RC) structure deterioration by initiation of steel rebar corrosion. These attacks are usually studied separately in the literature. Chloride-induced corrosion takes place mainly in marine environment or in the case of contact with deicing salts, while carbonation is systematically present in all RC structures at a variable degree. Since carbonation leads to significant microstructure changes, the effect of chloride ...

  7. Surface Chloride Concentration of Concrete under Shallow Immersion Conditions

    OpenAIRE

    Jun Liu; Kaifeng Tang; Dong Pan; Zongru Lei; Weilun Wang; Feng Xing

    2014-01-01

    Deposition of chloride ions in the surface layer of concrete is investigated in this study. In real concrete structure, chloride ions from the service environment can penetrate into concrete and deposit in the surface layer, to form the boundary condition for further diffusion towards the interior. The deposit amount of chloride ions in the surface layer is normally a function of time, rather than a constant. In the experimental investigation, concrete specimens with different mix proportions...

  8. Improved TPB-coated light guides for liquid argon TPC light detection systems

    International Nuclear Information System (INIS)

    Scintillation light produced in liquid argon (LAr) must be shifted from 128 nm to visible wavelengths in light detection systems used for liquid argon time-projection chambers (LArTPCs). To date, LArTPC light collection systems have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we report on light guides with improved attenuation lengths above 100 cm when measured in air. This is an important step in the development of meter-scale light guides for future LArTPCs. Improvements come from using a new acrylic-based coating, diamond-polished cast UV transmitting acrylic bars, and a hand-dipping technique to coat the bars. We discuss a model for connecting bar response in air to response in liquid argon and compare this to data taken in liquid argon. The good agreement between the prediction of the model and the measured response in liquid argon demonstrates that characterization in air is sufficient for quality control of bar production. This model can be used in simulations of light guides for future experiments

  9. Improved TPB-coated light guides for liquid argon TPC light detection systems

    Science.gov (United States)

    Moss, Z.; Bugel, L.; Collin, G.; Conrad, J. M.; Jones, B. J. P.; Moon, J.; Toups, M.; Wongjirad, T.

    2015-08-01

    Scintillation light produced in liquid argon (LAr) must be shifted from 128 nm to visible wavelengths in light detection systems used for liquid argon time-projection chambers (LArTPCs). To date, LArTPC light collection systems have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we report on light guides with improved attenuation lengths above 100 cm when measured in air. This is an important step in the development of meter-scale light guides for future LArTPCs. Improvements come from using a new acrylic-based coating, diamond-polished cast UV transmitting acrylic bars, and a hand-dipping technique to coat the bars. We discuss a model for connecting bar response in air to response in liquid argon and compare this to data taken in liquid argon. The good agreement between the prediction of the model and the measured response in liquid argon demonstrates that characterization in air is sufficient for quality control of bar production. This model can be used in simulations of light guides for future experiments.

  10. Fast-imaging and spectroscopic analysis of atmospheric argon streamers for large gap arc breakdown

    Science.gov (United States)

    Pachuilo, Michael; Stefani, Francis; Bengtson, Roger; Raja, Laxminarayan

    2014-10-01

    A non-equilibrium plasma source has been developed to assist in the low-voltage arc breakdown of large electrode gaps. The source consists of a dielectric embedded wire helically wound around a confining cylindrical quartz chamber. Annular electrodes cap the ends of the quartz chamber. An argon feed gas is used to provide a uniform environment and exhausts to ambient atmospheric conditions. A negative polarity 50 kV trigger pulse is applied to the embedded trigger wire to initiate the arc breakdown. Application of the trigger pulse produces a localized coronal discharges along the inner surface of the quartz tube. The corona provides seed electrons through which streamers propagate from one of the main discharge electrode along the quartz surface until it reaches the opposite electrode to bridge the gap. Once the gap is bridged a spark over occurs and robust arc discharge is formed in the chamber volume. Fast imaging of the streamer propagation establishes its velocity in the range of ~ 100 km/s. Spectroscopy of the streamer discharge in atmospheric argon has been conducted and electron temperature and number density estimated from a collision radiative model. Argon spectrum is dominated by neutral argon lines in the 650--950 nm range, and singly ionized argon lines are observed in the ultra-violet to near UV (300--400 nm). Research was performed in connection with AFOSR Contract FA9550-11-1-0062.

  11. N,N-Dimethyldehydroabietylammonium chloride ethanol monosolvate

    Directory of Open Access Journals (Sweden)

    Xiu-Zhi Huang

    2013-06-01

    Full Text Available The title compound {systematic name: 1-[(1R,4aS,10aR-7-isopropyl-1,4a-dimethyl-1,2,3,4,4a,9,10,10a-octahydrophenanthren-1-yl]-N,N-dimethylmethanaminium chloride ethanol monosolvate}, C22H36N+·Cl−·C2H6O, was synthesized from dehydroabietylamine by N-methylation with formaldehyde/formic acid and transformation into the hydrochloride. The dehydroabietyl moiety exhibits the usual conformation with the two cyclohexane rings in chair and half-chair conformations and a trans-ring junction. The crystal structure is built up from columns of the dehydroabietyl moieties stacked along the a axis. These columns are held together by the chloride ions via N—H...Cl and C—H...Cl interactions, which establish a two-dimensional network parallel to (010. The ethanol solvent molecules are located between the columns and anchored via O—H...Cl hydrogen bonds.

  12. Radiolytic preparation of anhydrous tin (2) chloride

    Science.gov (United States)

    Philipp, W. H.; Marsik, S. J.

    1973-01-01

    Anhydrous tin (2) chloride (SnCl2) is prepared by radiolysis with high energy electrons of a tin (4) chloride (SnCl4) solution in heptane. The SnCl4 is reduced to insoluble SNCl2. The energy yield, G(SnCl2), molecules of SnCl2, produced per 100 eV, increases with SnCl4 concentration from 1.6 at 0.15 M SnCl4 to 3.1 at 3.0 M SnCl4. Other parameters such as temperature total dose and beam current have little influence on G(SnCl2). The method may be used to prepare other metal halides if the higher valence, more covalent metal halide is soluble in aliphatic hydrocarbons and the lower more ionic metal halide is insoluble. The reaction mechanism is discussed; the radiolysis of both heptane and SnCl4 is involved. At high SnCl4 concentration G(SnCl2) appears to be limited by the yield of SnC13 radicals.

  13. Synthesis and structure characterization of diethyldiallylammonium chloride

    Institute of Scientific and Technical Information of China (English)

    刘立华; 龚竹青; 郑雅杰

    2003-01-01

    The unsaturated quaternary ammonium salt diethyldiallylammonium chloride(DEDAAC) was synthesized in a two-step synthetic method. The influences of the adding method of raw materials and temperature on the yields of diethylallylamine (DEAA), and drying and temperature on the synthesis of DEDAAC were investigated. The content of in-process product DEAA was determined by non-aqueous titration. The structure of product DEDAAC was identified with IR, 1 H NMR and elemental analysis. The results show that adding allyl chloride and sodium hydroxide alternately can increase the yield of DEAA and decrease by-products. In further synthesizing of DEDAAC from DEAA, the step of drying DEAA is very necessary. When DEAA is dried by solid sodium hydroxide, good columnar crystals with a high purity(mp 199.5-201.0 ℃) are obtained; when DEAA is undried or the content of water in DEAA is above 20%, only platelets with bad quality are obtained even without crystals. The suitable synthesis conditions for DEAA and DEDAAC are 35 ℃, 6 h and 40 ℃, 36 h, respectively, and their yields are 69.7% and 67.3%, respectively.

  14. Cobalt electrodeposition using urea and choline chloride

    International Nuclear Information System (INIS)

    The electrochemical behavior of Co(II) in urea-choline chloride-CoCl2 melt was investigated by cyclic voltammetry at 373 K. The results show that the reaction of Co(II) to Co is irreversible and it proceeds via a one-step two electrons transfer process. The diffusion coefficient of Co(II) was estimated to be 1.7 × 10−6 cm2 s−1 at 373 K. Electrodeposition of cobalt was studied at different cathodic potentials (-0.80 to -0.95 V) and at different temperatures (353 to 383 K) in eutectic mixture of choline chloride and urea (1:2 molar ratio). The deposits were characterized using scanning electron microscope (SEM), energy-dispersive spectroscopy (EDS), and X-ray diffraction (XRD). SEM images show that uniform, dense, and compact deposits were obtained at -0.80 V within a temperature range of 353 K to 373 K. EDS and XRD analysis confirm that high-purity metallic Co deposits were obtained

  15. The electrodeposition of lead from chloride electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Wright, A.

    1986-11-28

    At low current densities, lead was deposited onto a lead substrate as a fine powder that did not adhere well to the substrate. At higher current densities dendritic growth occurred. Lead does not adhere to a graphite substrate and, since copper and titanium substrates require higher cell voltages than lead substrates, these three substrates were rejected. The temperature of the electrolyte must be maintained above 69/sup 0/C to avoid the precipitation of lead chloride in the cell. Optimum current efficiencies at the anode and cathode were obtained at 80/sup 0/C, and no improvement in the morphology of the deposit was observed at higher temperatures. A combination of Quebracho extract and cuprous ions achieved the greatest improvement in the morphology of the deposit, while maintaining high current efficiencies at the anode and cathode. However, when the deposition time was increased, dendritic growth was much in evidence. A compact, adherent deposit of lead could not be obtained from chloride electrolytes. 22 refs., 21 figs., 11 tabs.

  16. Open cycle lithium chloride cooling system

    Science.gov (United States)

    Lenz, T. G.; Loef, G. O. G.; Iyer, R.; Wenger, J.

    1983-05-01

    A lithium chloride open cycle absorption chiller has been designed, built and tested. Solution reconcentration takes place in a small counter current packed column supplied with solar heated air. Removal of noncondensable gases that enter the chiller dissolved in the strong solution and the make-up refrigerant streams is accomplished by a liquid-jet ejector and a small vacuum pump. Cooling capacities approaching 1.4 tons and COP levels of 0.58 have been achieved at non-optimum operating conditions. Test results from preliminary system operation suggest that mass transfer processes in both the packed column reconcentrator and the absorber are controlled by concentration gradients in the lithium chloride solution. Liquid phase controlled mass transfer dictates an operating strategy different from the previously assumed gas phase controlled process to obtain maximum rates of evaporation in the packed column. Determination of optimal operating conditions leading to decreased electrical power consumption and improved cooling capacity and coefficient of performance will require further analysis and testing.

  17. Fault locator of an allyl chloride plant

    Directory of Open Access Journals (Sweden)

    Savković-Stevanović Jelenka B.

    2004-01-01

    Full Text Available Process safety analysis, which includes qualitative fault event identification, the relative frequency and event probability functions, as well as consequence analysis, was performed on an allye chloride plant. An event tree for fault diagnosis and cognitive reliability analysis, as well as a troubleshooting system, were developed. Fuzzy inductive reasoning illustrated the advantages compared to crisp inductive reasoning. A qualitative model forecast the future behavior of the system in the case of accident detection and then compared it with the actual measured data. A cognitive model including qualitative and quantitative information by fuzzy logic of the incident scenario was derived as a fault locator for an ally! chloride plant. The obtained results showed the successful application of cognitive dispersion modeling to process safety analysis. A fuzzy inductive reasoner illustrated good performance to discriminate between different types of malfunctions. This fault locator allowed risk analysis and the construction of a fault tolerant system. This study is the first report in the literature showing the cognitive reliability analysis method.

  18. Estimation of trace chloride in nuclear grade sodium

    International Nuclear Information System (INIS)

    The author represents a method to determinate trace levels of chloride in sodium coolant in a fast neutron reactor. Vacuum distillation is used for separating chloride from sodium matrix. After separation, matrix interference from sodium salts is eliminated and a large sample amount can be taken for analysing chloride. In contrast with other similar mercuric thiocyanate colorimetric method in China, this method minimizes a glaring blank of colorimetric solution and determining influence of temperature. Therefore, it increases the precision in analysing chloride. The results of the research demonstrate that when a level of chloride in sodium is less than 1 μg/g, the precision is 37% (n = 10). The recoveries of chloride in high pure sodium demonstrate that when 15-30 μg/g of chloride is added in sodium, the recovery is 97.8%-98.6% and when 4μg/g of chloride is added, then the average recovery is 99.2%. And the relative standard deviation is 16.2% (n =7). It is demonstrated that a monitoring requirement of chloride can be satisfied with this method in coolant of sodium in a fast neutron reactor

  19. Interpretation of postmortem vitreous concentrations of sodium and chloride.

    Science.gov (United States)

    Zilg, B; Alkass, K; Berg, S; Druid, H

    2016-06-01

    Vitreous fluid can be used to analyze sodium and chloride levels in deceased persons, but it remains unclear to what extent such results can be used to diagnose antemortem sodium or chloride imbalances. In this study we present vitreous sodium and chloride levels from more than 3000 cases. We show that vitreous sodium and chloride levels both decrease with approximately 2.2mmol/L per day after death. Since potassium is a well-established marker for postmortem interval (PMI) and easily can be analyzed along with sodium and chloride, we have correlated sodium and chloride levels with the potassium levels and present postmortem reference ranges relative the potassium levels. We found that virtually all cases outside the reference range show signs of antemortem hypo- or hypernatremia. Vitreous sodium or chloride levels can be the only means to diagnose cases of water or salt intoxication, beer potomania or dehydration. We further show that postmortem vitreous sodium and chloride strongly correlate and in practice can be used interchangeably if analysis of one of the ions fails. It has been suggested that vitreous sodium and chloride levels can be used to diagnose drowning or to distinguish saltwater from freshwater drowning. Our results show that in cases of freshwater drowning, vitreous sodium levels are decreased, but that this mainly is an effect of postmortem diffusion between the eye and surrounding water rather than due to the drowning process, since the decrease in sodium levels correlates with immersion time. PMID:27105154

  20. Durability of cracked fibre reinforced concrete structures exposed to chlorides

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place; Ekman, Tom; Hansen, Kurt Kielsgaard

    Durability studies are carried out by subjecting FRC-beams to combined mechanical and environmental load. Mechanical load is obtained by exposing beams to 4-point bending until a predefined crack width is reached, using a newly developed test setup. Exposure to a concentrated chloride solution is...... used as environmental load. The chloride penetration is characterized both qualitatively (UV-test) and quantitatively (chloride profile) and by microscopy. The test programme involves three different concrete qualities. Both steel fibres and polypropylene fibres are used in the concrete beams as well...... as main reinforcement. The effect of the cracks, the fibres and the concrete quality on the chloride penetration is studied....

  1. Catalytic Conversion of Cellulose to Levulinic Acid by Metal Chlorides

    Directory of Open Access Journals (Sweden)

    Beixiao Zhang

    2010-08-01

    Full Text Available The catalytic performance of various metal chlorides in the conversion of cellulose to levulinic acid in liquid water at high temperatures was investigated. The effects of reaction parameters on the yield of levulinic acid were also explored. The results showed that alkali and alkaline earth metal chlorides were not effective in conversion of cellulose, while transition metal chlorides, especially CrCl3, FeCl3 and CuCl2 and a group IIIA metal chloride (AlCl3, exhibited high catalytic activity. The catalytic performance was correlated with the acidity of the reaction system due to the addition of the metal chlorides, but more dependent on the type of metal chloride. Among those metal chlorides, chromium chloride was found to be exceptionally effective for the conversion of cellulose to levulinic acid, affording an optimum yield of 67 mol % after a reaction time of 180 min, at 200 °C, with a catalyst dosage of 0.02 M and substrate concentration of 50 wt %. Chromium metal, most of which was present in its oxide form in the solid sample and only a small part in solution as Cr3+ ion, can be easily separated from the resulting product mixture and recycled. Finally, a plausible reaction scheme for the chromium chloride catalyzed conversion of cellulose in water was proposed.

  2. Platinum uptake from chloride solutions using biosorbents

    Directory of Open Access Journals (Sweden)

    Mehmet Hakan Morcali

    2013-04-01

    Full Text Available Present work investigates platinum uptake from synthetically prepared, dilute platinum-bearing solutions using biomass residues, i.e. pistachio nut shell and rice husk, which are abundant in Turkey, and provides a comparison between these two biosorbents. Effects of the different uptake parameters, sorbent dosage, contact time, temperature and pH of solution on platinum uptake (% were studied in detail on a batch sorption. Before the pistachio nut shell was activated, platinum uptake (% was poor compared to the rice husk. However, after the pistachio nut shell was activated at 1000 °C under an argon atmosphere, the platinum uptake (% increased two-fold. The pistachio nut shell (original and activated and rice husk were shown to be better than commercially available activated carbon in terms of adsorption capacity. These two sorbents have also been characterized by FTIR and SEM. Adsorption equilibrium data best complied with the Langmuir isotherm model. Maximum adsorption capacities, Qmax, at 25 °C were found to be 38.31 and 42.02 mg.g- 1for the activated pistachio nut shell and rice husk, respectively. Thermodynamic calculations using the measured ∆H°, ∆S° and ∆G° values indicate that the uptake process was spontaneous and endothermic. The experimental data were shown to be fit the pseudo-second-order kinetic model.

  3. Spectroscopic Characterization of Post-Cluster Argon Plasmas During the Blast Wave Expansion

    International Nuclear Information System (INIS)

    In this work we present temperature diagnostics of an expanding laser-produced argon plasma. A short-pulse (35fs) laser with an intensity of I = 1017W/cm2 deposits ∼ 100 mJ of energy into argon clusters. This generates a hot plasma filament that develops into a cylindrically expanding shock. We develop spectral diagnostics for the temperatures of the argon plasma in the shock region and the preionized region ahead of the shock. A collisional-radiative model is applied to explore line intensity ratios derived from Ar II - Ar IV spectra that are sensitive to temperatures in a few eV range. The results of hydrodynamic simulations are employed to derive a time dependent radiative transport calculation that generates the theoretical emission spectra from the expanding plasma

  4. The WArP Experiment: A Double-Phase Argon Detector for Dark Matter Searches

    International Nuclear Information System (INIS)

    Cryogenic noble liquids emerged in the previous decade as one of the best media to perform WIMP dark matter searches, in particular due to the possibility to scale detector volumes to multiton sizes. The WArP experiment was then developed as one of the first to implement the idea of coupling Argon in liquid and gas phase, in order to discriminate β/γ-interactions from nuclear recoils and then achieve reliable background rejection. Since its construction, other projects spawned, employing Argon and Xenon and following its steps. The WArP 100l detector was assembled in 2008 at the Gran Sasso National Laboratories (LNGS), as the final step of a years-long R&D programme, aimed at characterising the technology of Argon in double phase for dark matter detection. Though it never actually performed a physics run, a technical run was taken in 2011, to characterise the detector response

  5. Compatibility of the argon and KTP lasers with middle ear implants.

    Science.gov (United States)

    Wanamaker, H H; Silverstein, H

    1993-06-01

    Visible-spectrum lasers (argon, KTP) are becoming common tools in otology. Concern over transmission of disease by homograft tissue has focused attention on synthetic materials such as Silastic, Polycel, hydroxylapatite, and Teflon. This study sought to determine the effects of argon and KTP lasers on materials used in stapes and chronic ear surgery. Silastic sheeting, hydroxylapatite and polycel total ossicular replacement prostheses (TORPs) and partial ossicular replacement prostheses (PORPs), and platinum wire/Teflon stapes prostheses were exposed to argon and KTP laser energy at clinical power settings. Effects of the two lasers were similar. The presence of pigment (char or blood) was necessary to produce any effect. Silastic transmitted energy to underlying material. Hydroxylapatite cracked and shattered. Polycel vaporized and melted, as did Teflon. Clinical implications of these interactions on primary and revision otologic surgeries will be discussed. PMID:8388975

  6. Negative corona in silane-argon-hydrogen mixtures at low pressures

    International Nuclear Information System (INIS)

    Current pulses have been measured in negative corona discharges in argon-hydrogen and silane-argon-hydrogen mixtures near the Paschen minimum. It was found that the current pulses appear only on the right branch of the Paschen curve and have shapes similar to those of subnormal oscillations in dc discharges between parallel-plane electrodes. The effects of gas temperature and negative ions on the current pulse shape and size are examined. It appears that a small admixture of silane into an argon-hydrogen discharge results in a more pronounced ion-ion phase and doubles the pulse repetition frequency, while an increase in gas temperature acts in exactly the opposite way. The implications of these results on theories of current pulse formation are discussed

  7. Operation of a GERDA phase I prototype detector in liquid argon and nitrogen

    International Nuclear Information System (INIS)

    A GERDA phase I prototype detector, consisting of a bare non-enriched high-purity (HP) p-type germanium diode mounted in a low mass holder has been operated both in liquid nitrogen and liquid argon. Because of its high density, liquid argon has been selected as cryogenic liquid and shield for GERDA experiment. The testing of this detector assembly has been carried out in the underground detector laboratory at LNGS, and at the detector manufacturer. The best resolution achieved is 2.2 keV FWHM at 1.332 MeV, which is the same as the resolution measured in a standard test cryostat. The long-term measurements with the prototype detector are performed in liquid argon. Up to now, 38 thermal cycles have been carried out with this detector. The operations, measurements and results of the prototype detector testing are summarized. (orig.)

  8. A novel diagnostic for time-resolved spectroscopic argon and lithium density measurements

    International Nuclear Information System (INIS)

    A new diagnostic technique for determining neutral gas and metal vapor densities over a wide pressure range with high time resolution is described. A compact, current-stabilized hollow cathode/anode discharge is use to ionize the gas and/or trace impurity to be analyzed. We report proof-of-principle operation of the diagnostic in a well characterized argon discharge in the pressure range 6.7-265 Pa. The intensity ratio of neutral and singly ionized argon lines (I ArI/I ArII) is shown to increase monotonically with the neutral argon density. In a second experiment, absolute neutral lithium vapor densities have been measured using this diagnostic

  9. Enhancement of the EUV emission of a metallic capillary discharge operated with argon ambient gas

    Energy Technology Data Exchange (ETDEWEB)

    Chan, L. S., E-mail: lschan1982@yahoo.com; Tan, D., E-mail: lschan1982@yahoo.com; Saboohi, S., E-mail: lschan1982@yahoo.com; Yap, S. L., E-mail: lschan1982@yahoo.com; Wong, C. S., E-mail: lschan1982@yahoo.com [Plasma Technology Research Centre, Physics Department, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2014-03-05

    In this work, the metallic capillary discharge is operated with two different ambients: air and argon. In the experiments reported here, the chamber is first evacuated to 10{sup −5} mbar. The discharge is initiated by the transient hollow cathode effect generated electron beam, with either air ambient or argon ambient at 10{sup −4} mbar. The bombardment of electron beam at the tip of the stainless steel anode gives rise to a metallic vapor, which is injected into the capillary and initiates the main discharge through the capillary. The EUV emission is measured for different discharge voltages for both conditions and compared. It is found that the metallic capillary discharge with argon ambientis able to produce higher EUV energy compared to that with air ambient.

  10. The effects of accelerated heavy nuclei of neon and argon on mammalian cells in culture

    International Nuclear Information System (INIS)

    The survival of human T-1 kidney cells in high-energy neon (400MeV/nucleon) and argon (500MeV/nucleon) beams has been studied at the Berkeley Bevalac. Cells were plated in monolayers on glass and studied at different residual-range values. The survival curves depend on LET and on particle velocity. The effectiveness of the beams increases as the range decreases, except for argon beams with very low range values, where the effectiveness decreases again. The 'oxygen effect' is high at high particle energies (2.6 for neon and 2.4 for argon); it decreases to values between 1.1 and 1.3 near the Bragg peak. (author)

  11. Molecular dynamics simulation of an argon cluster filled inside carbon nanotubes

    International Nuclear Information System (INIS)

    The effects of the diameters of single-walled carbon nanotubes (SWCNTs) (7.83 Å to 27.40 Å) and temperature (20 K–45 K) on the equilibrium structure of an argon cluster are systematically studied by molecular dynamics simulation with consideration of the SWCNTs to be fixed. Since the diameters of SWCNTs with different chiralities increase when temperature is fixed at 20 K, the equilibrium structures of the argon cluster transform from monoatomic chains to helical and then to multishell coaxial cylinders. Chirality has almost no noticeable influence on these cylindrosymmetric structures. The effects of temperature and a non-equilibrium sudden heating process on the structures of argon clusters in SWCNTs are also studied by molecular dynamics simulation. (condensed matter: structural, mechanical, and thermal properties)

  12. Synodic and semiannual oscillations of argon-40 in the lunar exosphere

    Science.gov (United States)

    Hodges, R. Richard; Mahaffy, Paul R.

    2016-01-01

    The neutral mass spectrometer on the Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft collected a trove of exospheric data, including a set of high-quality measurements of radiogenic 40Ar over a period of 142 days. Data synthesis studies, using well-established exosphere simulation tools, show that the LADEE argon data are consistent with an exosphere-regolith interaction that is dominated by adsorption and that the desorption process generates the Armand distribution of exit velocities. The synthesis work has uncovered an apparent semiannual oscillation of argon that is consistent with temporal sequestration in the seasonal cold traps created at the poles by the obliquity of the Moon. In addition, the LADEE data provide new insight into the pristine nature of lunar regolith, its spatially varying sorption properties, and the influence of sorption processes on the synodic oscillation of the argon exosphere.

  13. Atomistic Simulation of Properties of Ultra-thin Layer of Liquid Argon Compressed Between Diamond Surfaces

    Directory of Open Access Journals (Sweden)

    A.V. Khomenko

    2016-03-01

    Full Text Available Using the method of classical molecular dynamics we investigate the properties of ultrathin film of liquid argon, which consists of one or two layers of molecules and is confined by two atomically smooth crystalline diamond surfaces. The aim of the research is validating the use of rigid surfaces and one of the available models of the argon molecule. We study the behavior of the equilibrium and dynamic characteristics of the system. It is shown that at increasing external load the transition of film in the solid-like state occurs, which is indicated by the behavior of the velocity autocorrelation function of argon molecules, reduction of the magnitude of the diffusion coefficient and the shear viscosity increase. The organization of molecules in layers and the presence of their in-plane ordering are revealed. The dependences of the kinetic friction force on time and load are obtained. The results are compared with experimental data.

  14. Theoretical and experimental comparisons of Gamble 2 argon gas puff experiments

    International Nuclear Information System (INIS)

    A one-dimensional radiative MHD analysis of an imploding argon gas puff plasma is performed. The calculations are set up to approximate the conditions of a series of argon gas puff experiments that were carried out on the NRL Gamble II generator. Annular gas puffs (2.5 cm diameter) are imploded with a 1.2-MA peak driving current for different initial argon mass loadings. Comparisons are made with the experimental results for implosion times, K, L-shell x-ray emission, and energy coupled from the generator to the plasma load. The purpose of these calculations is to provide a foundation from which a variety of physical phenomena which influence the power and total energy of the x-ray emission can be analyzed. Comparisons with similar experimental and theoretical results for aluminum plasmas are discussed

  15. Atomistic-Continuum Hybrid Simulation of Heat Transfer between Argon Flow and Copper Plates

    CERN Document Server

    Mao, Yijin; Chen, C L

    2016-01-01

    A simulation work aiming to study heat transfer coefficient between argon fluid flow and copper plate is carried out based on atomistic-continuum hybrid method. Navier-Stokes equations for continuum domain are solved through the Pressure Implicit with Splitting of Operators (PISO) algorithm, and the atom evolution in molecular domain is solved through the Verlet algorithm. The solver is validated by solving Couette flow and heat conduction problems. With both momentum and energy coupling method applied, simulations on convection of argon flows between two parallel plates are performed. The top plate is kept as a constant velocity and has higher temperature, while the lower one, which is modeled with FCC copper lattices, is also fixed but has lower temperature. It is found that, heat transfer between argon fluid flow and copper plate in this situation is much higher than that at macroscopic when the flow is fully developed.

  16. Lattice gas model for fragmentation from argon on scandium to gold on gold

    CERN Document Server

    Das-Gupta, S; Gupta, Subal Das; Pan, Jicai

    1995-01-01

    The recent fragmentation data for central collisions of Gold on Gold are even qualitatively different from those for central collisions of Argon on Scandium. The latter can be fitted with a lattice gas model calculation. Effort is made to understand why the model fails for Gold on Gold. The calculation suggests that the large Coulomb interaction which is operative for the larger system is responsible for this discrepancy. This is demonstrated by mapping the lattice gas model to a molecular dynamics calculation for disassembly. This mapping is quite faithful for Argon on Scandium but deviates strongly for Gold on Gold. The molecular dynamics calculation for disassembly reproduces the characteristics of the fragmentation data for both Gold on Gold and Argon on Scandium.

  17. Argon: Systematic Review on Neuro- and Organoprotective Properties of an “Inert” Gas

    Directory of Open Access Journals (Sweden)

    Anke Höllig

    2014-10-01

    Full Text Available Argon belongs to the group of noble gases, which are regarded as chemically inert. Astonishingly some of these gases exert biological properties and during the last decades more and more reports demonstrated neuroprotective and organoprotective effects. Recent studies predominately use in vivo or in vitro models for ischemic pathologies to investigate the effect of argon treatment. Promising data has been published concerning pathologies like cerebral ischemia, traumatic brain injury and hypoxic ischemic encephalopathy. However, models applied and administration of the therapeutic gas vary. Here we provide a systematic review to summarize the available data on argon’s neuro- and organoprotective effects and discuss its possible mechanism of action. We aim to provide a summary to allow further studies with a more homogeneous setting to investigate possible clinical applications of argon.

  18. Studies with a liquid argon time projection chamber. Addressing technological challenges of large-scale detectors

    International Nuclear Information System (INIS)

    Michael Schenk evaluates new technologies and methods, such as cryogenic read-out electronics and a UV laser system, developed to optimise the performance of large liquid argon time projection chambers (LArTPC). Amongst others, the author studies the uniformity of the electric field produced by a Greinacher high-voltage generator operating at cryogenic temperatures, measures the linear energy transfer (LET) of muons and the longitudinal diffusion coefficient of electrons in liquid argon. The results are obtained by analysing events induced by cosmic-ray muons and UV laser beams. The studies are carried out with ARGONTUBE, a prototype LArTPC in operation at the University of Bern, Switzerland, designed to investigate the feasibility of drift distances of up to five metres for electrons in liquid argon.

  19. Ionic Wind Phenomenon and Charge Carrier Mobility in Very High Density Argon Corona Discharge Plasma

    Science.gov (United States)

    Nur, M.; Bonifaci, N.; Denat, A.

    2014-04-01

    Wind ions phenomenon has been observed in the high density argon corona discharge plasma. Corona discharge plasma was produced by point to plane electrodes and high voltage DC. Light emission from the recombination process was observed visually. The light emission proper follow the electric field lines that occur between point and plane electrodes. By using saturation current, the mobilities of non-thermal electrons and ions have been obtained in argon gas and liquid with variation of density from 2,5 1021 to 2 1022 cm-3. In the case of ions, we found that the behaviour of the apparent mobility inversely proportional to the density or follow the Langevin variation law. For non-thermal electron, mobility decreases and approximately follows a variation of Langevin type until the density <= 0,25 the critical density of argon.

  20. Atmospheric Pressure Cold Argon/Oxygen Plasma Jet Assisted by Preionization of Syringe Needle Electrode

    International Nuclear Information System (INIS)

    An atmospheric pressure nonequilibrium argon/oxygen plasma jet assisted by the preionization of syringe needle electrode discharge is reported. With the syringe needle plasma as its pre-ionization source, the hybrid barrier-jet was shown to generate uniform discharge with a lower breakdown voltage and a relatively low gas temperature varying from 390 K to 440 K, even when the vol.% oxygen in argon was up to 6%. Utilizing the actinometry method, the concentration of atomic oxygen was estimated to be about in an orders of magnitude of 1017 cm-3. The argon/oxygen plasma jet was then employed to clean out heat transfer oil, with a maximum cleaning rate of 0.1 mm/s achieved.

  1. Operation of a high purity germanium crystal in liquid argon as a Compton suppressed radiation spectrometer

    CERN Document Server

    Orrell, J L; Amsbaugh, J F; Doe, P J; Hossbach, T W; Orrell, John L.; Aalseth, Craig E.; Amsbaugh, John F.; Doe, Peter J.; Hossbach, Todd W.

    2007-01-01

    A high purity germanium crystal was operated in liquid argon as a Compton suppressed radiation spectrometer. Spectroscopic quality resolution of less than 1% of the full-width half maximum of full energy deposition peaks was demonstrated. The construction of the small apparatus used to obtain these results is reported. The design concept is to use the liquid argon bath to both cool the germanium crystal to operating temperatures and act as a scintillating veto. The scintillation light from the liquid argon can veto cosmic-rays, external primordial radiation, and gamma radiation that does not fully deposit within the germanium crystal. This technique was investigated for its potential impact on ultra-low background gamma-ray spectroscopy. This work is based on a concept initially developed for future germanium-based neutrinoless double-beta decay experiments.

  2. Effect of application of ammonium chloride and calcium chloride on alfalfa cation-anion content and yield.

    Science.gov (United States)

    Goff, J P; Brummer, E C; Henning, S J; Doorenbos, R K; Horst, R L

    2007-11-01

    A major factor predisposing the cow to periparturient hypocalcemia, or milk fever, is being fed a prepartum ration with a high dietary cation-anion difference (DCAD). The DCAD can be favorably altered to prevent milk fever by decreasing K and Na or increasing Cl and S in forages for cows in late gestation. The objective of this study was to test the hypothesis that application of Cl to alfalfa could increase Cl in forage, thereby lowering DCAD. We conducted a field experiment at 2 Iowa locations in which established plots of alfalfa were treated in April 2001 with 0, 56, 112, or 168 kg of Cl/ha using ammonium chloride, calcium chloride, or a mix of the 2 sources with equal amounts of chloride coming from each source. Plots were harvested 4 times in 2001 and once in 2002 and plant tissue analyzed for mineral composition. Applying chloride from either source once in the spring resulted in increased plant chloride content over all 4 cuttings for that year. Averaged across both locations, chloride levels were elevated from 0.52% in control plots to 0.77, 0.87, and 0.89% Cl in plots treated with 56, 112, and 168 kg of Cl/ha, respectively. Chloride application had no effect on plant potassium, sodium, calcium, magnesium, or phosphorus. These results suggest chloride application can elevate chloride content and lower DCAD values of alfalfa, and also maintain crop yield. PMID:17954756

  3. THE COMPATIBILITY OF BLENDS OF POLY(VINYL CHLORIDE) OR CHLORINATED POLY(VINYL CHLORIDE) WITH POLY(METHYL METHACRYLATE)

    Institute of Scientific and Technical Information of China (English)

    WANG Qingguo; CHENG Rongshi

    1988-01-01

    IR spectral shifts of carbonyl vibrational absorption for ethyl acetate, which acts analogically as the structural unit of poly(methyl methacrylate), in cyclohexane, chloroform, chlorinated paraffins, poly(vinyl chloride) and chlorinated poly(vinyl chloride) were measured. The results suggest that there are specific interactions between the carbonyl groups and the chlorinated hydrocarbons which could be responsible for the apparent compatibility of poly(vinyl chloride) -poly(methyl methacrylate) and chlorinated poly(vinyl chloride) -poly(methyl methacrylate) blends. Additionally, the effects of the preparation mode of blend films on phase separation and observed compatibility are discussed.

  4. Performance of the Electronic Readout of the ATLAS Liquid Argon Calorimeters

    CERN Document Server

    Abreu, H; Aleksa, M; Aperio Bella, L; Archambault, JP; Arfaoui, S; Arnaez, O; Auge, E; Aurousseau, M; Bahinipati, S; Ban, J; Banfi, D; Barajas, A; Barillari, T; Bazan, A; Bellachia, F; Beloborodova, O; Benchekroun, D; Benslama, K; Berger, N; Berghaus, F; Bernat, P; Bernier, R; Besson, N; Binet, S; Blanchard, JB; Blondel, A; Bobrovnikov, V; Bohner, O; Boonekamp, M; Bordoni, S; Bouchel, M; Bourdarios, C; Bozzone, A; Braun, HM; Breton, D; Brettel, H; Brooijmans, G; Caputo, R; Carli, T; Carminati, L; Caughron, S; Cavalleri, P; Cavalli, D; Chareyre, E; Chase, RL; Chekulaev, SV; Chen, H; Cheplakov, A; Chiche, R; Citterio, M; Cojocaru, C; Colas, J; Collard, C; Collot, J; Consonni, M; Cooke, M; Copic, K; Costa, GC; Courneyea, L; Cuisy, D; Cwienk, WD; Damazio, D; Dannheim, D; De Cecco, S; De La Broise, X; De La Taille, C; de Vivie, JB; Debennerot, B; Delagnes, E; Delmastro, M; Derue, F; Dhaliwal, S; Di Ciaccio, L; Doan, O; Dudziak, F; Duflot, L; Dumont-Dayot, N; Dzahini, D; Elles, S; Ertel, E; Escalier, M; Etienvre, AI; Falleau, I; Fanti, M; Farooque, T; Favre, P; Fayard, Louis; Fent, J; Ferencei, J; Fischer, A; Fournier, D; Fournier, L; Fras, M; Froeschl, R; Gadfort, T; Gallin-Martel, ML; Gibson, A; Gillberg, D; Gingrich, DM; Göpfert, T; Goodson, J; Gouighri, M; Goy, C; Grassi, V; Gray, J; Guillemin, T; Guo, B; Habring, J; Handel, C; Heelan, L; Heintz, H; Helary, L; Henrot-Versille, S; Hervas, L; Hobbs, J; Hoffman, J; Hostachy, JY; Hoummada, A; Hrivnac, J; Hrynova, T; Hubaut, F; Huber, J; Iconomidou-Fayard, L; Iengo, P; Imbert, P; Ishmukhametov, R; Jantsch, A; Javadov, N; Jezequel, S; Jimenez Belenguer, M; Ju, XY; Kado, M; Kalinowski, A; Kar, D; Karev, A; Katsanos, I; Kazarinov, M; Kerschen, N; Kierstead, J; Kim, MS; Kiryunin, A; Kladiva, E; Knecht, N; Kobel, M; Koletsou, I; König, S; Krieger, P; Kukhtin, V; Kuna, M; Kurchaninov, L; Labbe, J; Lacour, D; Ladygin, E; Lafaye, R; Laforge, B; Lamarra, D; Lampl, W; Lanni, F; Laplace, S; Laskus, H; Le Coguie, A; Le Dortz, O; Le Maner, C; Lechowski, M; Lee, SC; Lefebvre, M; Leonhardt, K; Lethiec, L; Leveque, J; Liang, Z; Liu, C; Liu, T; Liu, Y; Loch, P; Lu, J; Ma, H; Mader, W; Majewski, S; Makovec, N; Makowiecki, D; Mandelli, L; Mangeard, PS; Mansoulie, B; Marchand, JF; Marchiori, G; Martin, D; Martin-Chassard, G; Martin dit Latour, B; Marzin, A; Maslennikov, A; Massol, N; Matricon, P; Maximov, D; Mazzanti, M; McCarthy, T; McPherson, R; Menke, S; Meyer, JP; Ming, Y; Monnier, E; Mooshofer, P; Neganov, A; Niedercorn, F; Nikolic-Audit, I; Nugent, IM; Oakham, G; Oberlack, H; Ocariz, J; Odier, J; Oram, CJ; Orlov, I; Orr, R; Parsons, JA; Peleganchuk, S; Penson, A; Perini, L; Perrodo, P; Perrot, G; Perus, A; Petit, E; Pisarev, I; Plamondon, M; Poffenberger, P; Poggioli, L; Pospelov, G; Pralavorio, P; Prast, J; Prudent, X; Przysiezniak, H; Puzo, P; Quentin, M; Radeka, V; Rajagopalan, S; Rauter, E; Reimann, O; Rescia, S; Resende, B; Richer, JP; Ridel, M; Rios, R; Roos, L; Rosenbaum, G; Rosenzweig, H; Rossetto, O; Roudil, W; Rousseau, D; Ruan, X; Rudert, A; Rusakovich, N; Rusquart, P; Rutherfoord, J; Sauvage, G; Savine, A; Schaarschmidt, J; Schacht, P; Schaffer, A; Schram, M; Schwemling, P; Seguin Moreau, N; Seifert, F; Serin, L; Seuster, R; Shalyugin, A; Shupe, M; Simion, S; Sinervo, P; Sippach, W; Skovpen, K; Sliwa, R; Soukharev, A; Spano, F; Stavina, P; Straessner, A; Strizenec, P; Stroynowski, R; Talyshev, A; Tapprogge, S; Tarrade, F; Tartarelli, GF; Teuscher, R; Tikhonov, Yu; Tocut, V; Tompkins, D; Thompson, P; Tisserant, S; Todorov, T; Tomasz, F; Trincaz-Duvoid, S; Trinh, Thi N; Trochet, S; Trocme, B; Tschann-Grimm, K; Tsionou, D; Ueno, R; Unal, G; Urbaniec, D; Usov, Y; Voss, K; Veillet, JJ; Vincter, M; Vogt, S; Weng, Z; Whalen, K; Wicek, F; Wilkens, H; Wingerter-Seez, I; Wulf, E; Yang, Z; Ye, J; Yuan, L; Yurkewicz, A; Zarzhitsky, P; Zerwas, D; Zhang, H; Zhang, L; Zhou, N; Zimmer, J; Zitoun, R; Zivkovic, L

    2010-01-01

    The ATLAS detector has been designed for operation at the Large Hadron Collider at CERN. ATLAS includes electromagnetic and hadronic liquid argon calorimeters, with almost 200,000 channels of data that must be sampled at the LHC bunch crossing frequency of 40 MHz. The calorimeter electronics calibration and readout are performed by custom electronics developed specifically for these purposes. This paper describes the system performance of the ATLAS liquid argon calibration and readout electronics, including noise, energy and time resolution, and long term stability, with data taken mainly from full-system calibration runs performed after installation of the system in the ATLAS detector hall at CERN.

  5. Transport coefficients of helium-argon mixture based on ab initio potential.

    Science.gov (United States)

    Sharipov, Felix; Benites, Victor J

    2015-10-21

    The viscosity, thermal conductivity, diffusion coefficient, and thermal diffusion factor of helium-argon mixtures are calculated for a wide range of temperature and for various mole fractions up to the 12th order of the Sonine polynomial expansion with an ab initio intermolecular potential. The calculated values for these transport coefficients are compared with other data available in the open literature. The comparison shows that the obtained transport coefficients of helium-argon mixture have the best accuracy for the moment. PMID:26493894

  6. The ArDM, a ton-scale liquid argon experiment for direct dark matter detection

    International Nuclear Information System (INIS)

    Full text: The ArDM is a 1-ton liquid argon based experiment which aims at the direct detection of Weakly Interacting Massive Particles (WIMPs). The detector is sensitive to the small signals of scintillation light and the ionization charge independently. The sufficient discrimination between nuclear recoils and the background is possible by the ratio of scintillation to ionization and by the different time structure of the scintillation. In the present time the experiment is under construction at CERN. The detector was recently tested being fully filled with Liquid Argon. Promising results on the light yield and on the detector performance were obtained. (author)

  7. Research of On-line Analytical Method of Trace Oxygen and Water in Argon

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Metal sodium has an active chemical quality. When it is used as a coolant in a fast neutron reactor, it must be protected by a cover gas argon for safety operation of the reactor. But oxygen and water in argon can produce chemical reaction with sodium. Then sodium hydroxide, sodium oxide and hydrogen can be produced. This will be harmful to the safety operation of reactor. The purpose of controlling a level of impurity in the cover gas is for controlling a level of impurity in sodium. The research is to find an on-line determining method and a sampling system to monitor

  8. Liquid Argon Pollution Tests of the ATLAS Detector Materials at IBR-2 Reactor in Dubna

    CERN Document Server

    Leroy, C; Cheplakov, A P; Chumakov, V; Golikov, V; Golovanov, L B; Golubyh, S M; Kukhtin, V; Kulagin, E; Luschikov, V; Minashkin, V F; Shalyugin, A N; Tsvinev, A P

    1999-01-01

    A cold test facility has been in operation since October 1998 at the IBR-2 reactor of JINR, Dubna. During four measurement campaigns, various samples of the ATLAS forward (FCAL) and hadronic end cap (HEC) calorimeter materials have been exposed to a fast neutron ($E_n \\geq 100$ keV) fluence of about 10$^{16}$~n~cm$^{-2}$. The samples were immersed in a liquid argon cryostat, and an $\\alpha$-cell has been used as purity monitor. Results of the liquid argon pollution study obtained during these measurement campaigns are presented.

  9. Irradiation tests of ATLAS liquid argon forward calorimeter (FCAL) electronics components

    CERN Document Server

    Leroy, C; Golikov, V; Golubyh, S M; Kukhtin, V; Kulagin, E; Luschikov, V; Merkulov, L; Minashkin, V F; Shalyugin, A N

    2002-01-01

    FCAL resistors, capacitors, and transformers together with capacitors and sintimid disks of the purity monitor have been irradiated in liquid argon to study their possible lead to argon pollution at a maximal neutron fluence of 1016 n cm-2 at the IBR-2 reactor of JINR, Dubna. The results of charge collection measurements before and after irradiation are reported. Electrical measurement on these FCAL capacitors, resistors and transformers were also performed after irradiation. In general, the results of resistance, capacitance, impedance, leakage current and high voltage breakdown measurements after irradiation show minor changes of value only for some parameters from nominal values or values measured before irradiation.

  10. The Discovery of Argon in Comet C/1995 O1 (Hale-Bopp)

    CERN Document Server

    Stern, S A; Festou, M C; Parker, J W; A'Hearn, M F; Wilkinson, E; Gladstone, G R

    2000-01-01

    On 30.14 March 1997 we observed the EUV spectrum of the bright comet C/1995 O1 (Hale-Bopp) at the time of its perihelion, using our EUVS sounding rocket telescope/spectrometer. The spectra reveal the presence H Ly beta, O+, and, most notably, Argon. Modelling of the retrieved Ar production rates indicates that comet Hale-Bopp is enriched in Ar relative to cosmogonic expectations. This in turn indicates that Hale-Bopp's deep interior has never been exposed to the 35-40 K temperatures necessary to deplete the comet's primordial argon supply.

  11. Heat Transfer During Evaporation of Cesium From Graphite Surface in an Argon Environment

    Directory of Open Access Journals (Sweden)

    Bespala Evgeny

    2016-01-01

    Full Text Available The article focuses on discussion of problem of graphite radioactive waste formation and accumulation. It is shown that irradiated nuclear graphite being inalienable part of uranium-graphite reactor may contain fission and activation products. Much attention is given to the process of formation of radioactive cesium on the graphite element surface. It is described a process of plasma decontamination of irradiated graphite in inert argon atmosphere. Quasi-one mathematical model is offered, it describes heat transfer process in graphite-cesium-argon system. Article shows results of calculation of temperature field inside the unit cell. Authors determined the factors which influence on temperature change.

  12. Liquid argon pollution tests of the ATLAS detector materials at IBR-2 reactor in Dubna

    International Nuclear Information System (INIS)

    A cold test facility has been in operation since October 1998 at the IBR-2 reactor of JINR, Dubna. During four measurement campaigns, various samples of the ATLAS forward (FCAL) and hadronic end-cap (HEC) calorimeter materials have been exposed to a fast neutron (En ≥ 100 keV) fluence of about 1016 cm-2. The samples were immersed in a liquid argon cryostat, and an α cell has been used as a purity monitor. Results of the liquid argon pollution study obtained during these measurement campaigns are presented

  13. Physiological responses of Vigna radiata L. to nitrogen and argon+ laser irradiation - Short Communication

    International Nuclear Information System (INIS)

    The effect of nitrogen laser (337.1 nm) and argon+ laser (514.5 nm) irradiation on physiological responses in the green gram seedlings was studied. The shoot and root lengths and fresh and dry weights of the seedlings increased with 30 min exposure to nitrogen laser and 5 min exposure to Argon+ laser. Protein content was maximum with 20 min exposure to N laser and 5 min exposure to Ar+ laser, while DNA and RNA contents were maximum at 5 min exposure with both the laser treatments

  14. The clock distribution system for the ATLAS Liquid Argon Calorimeter Phase-I Upgrade Demonstrator

    International Nuclear Information System (INIS)

    A prototype Liquid-argon Trigger Digitizer Board (LTDB), called the LTDB Demonstrator, has been developed to demonstrate the functions of the ATLAS Liquid Argon Calorimeter Phase-I trigger electronics upgrade. Forty Analog-to-Digital converters and four FPGAs with embedded multi-gigabit-transceivers on each Demonstrator need high quality clocks. A clock distribution system based on commercial components has been developed for the Demonstrator. The design of the clock distribution system is presented. The performance of the clock distribution system has been evaluated. The components used in the clock distribution system have been qualified to meet radiation tolerance requirements of the Demonstrator

  15. Pulse Compression by Filamentation in Argon with an Acoustic Optical Programmable Dispersive Filter for Predispersion Compensation

    Institute of Scientific and Technical Information of China (English)

    CHEN Xiao-Wei; JIANG Yong-Liang; LENG Yu-Xin; LIU Jun; GE Xiao-Chun; LI Ru-Xin; XU Zhi-Zhan

    2006-01-01

    @@ We have experimentally demonstrated pulses 0.4 mJ in duration smaller than 12 fs with an excellent spatial beam profile by self-guided propagation in argon. The original 52fs pulses from the chirped pulsed amplification laser system are first precompressed to 32 fs by inserting an acoustic optical programmable dispersive filter instrument into the laser system for spectrum reshaping and dispersion compensation, and the pulse spectrum is subsequently broadened by filamentation in an argon cell. By using chirped mirrors for post-dispersion compensation, the pulses are successfully compressed to smaller than 12fs.

  16. Application of argon laser LAK-1 for therapy in selected blood vessel diseases

    Science.gov (United States)

    Szymanczyk, Jacek; Golebiowska, Aleksandra; Michalska, I.; Nowakowski, Wlodzimierz

    1995-03-01

    Argon laser was applied in 172 patients with various vascular disorders and epidermal nevi. The best therapeutical results were obtained in facial telangiectasia and in cavernous hemangiomas, in which there was a complete or almost complete regression. In capillary facial hemangiomas in 49 patients (79%) clearing of 50% to 75% was obtained, and in epidermal nevi the full regression was in 4 (44%) of the cases, and 50% regression in 4 (44%). In telangiectasia of the lower limbs the results were not satisfactory. We stress that cavernous, and capillary hemangiomas, as well as facial telangiectasia are an indication for the argon laser therapy.

  17. A 20-Liter Test Stand with Gas Purification for Liquid Argon Research

    CERN Document Server

    Li, Yichen; Tang, Wei; Joshi, Jyoti; Qian, Xin; Diwan, Milind; Kettell, Steve; Morse, William; Rao, Triveni; Stewart, James; Tsang, Thomas; Zhang, Lige

    2016-01-01

    We describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). This system utilizes a simple, cost-effective gas argon (GAr) purification to achieve ultra-high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. A gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.

  18. Argon plasma-assisted PDMS–LTCC bonding technique for microsystem applications

    International Nuclear Information System (INIS)

    A method for transparent polymer (polydimethylosiloxane, PDMS) to glass-covered low-temperature co-fired ceramics (LTCC) using microwave argon plasma is reported in this paper. Changes in the composition of both materials before and after plasma treatment are investigated with x-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy-attenuated total reflection and contact angle measurements. The results obtained for PDMS and glass-covered LTCC modified with argon plasma are compared with previously reported results received for oxygen plasma. Moreover, a comparison of adhesion between PDMS and glass-covered LTCC bonded together using Ar and O2 plasma is made using a material testing machine

  19. Experimental Measurement for Shock Velocity-Mass Velocity Relationship of Liquid Argon Up to 46 GPa

    Institute of Scientific and Technical Information of China (English)

    孟川民; 施尚春; 董石; 杨向东; 谭华; 经福谦

    2003-01-01

    Shock properties of liquid argon were measured in the shock pressure up to 46 GPa by employing the two-stage light gas gun. Liquid nitrogen was used as coolant liquid. The cryogenic target system has been improved to compare with the previous work. Shock velocities were measured with self-shorting electrical probes. Impactor velocities were measured with an electrical-magnetic induction system. Mass velocities were obtained by mean of shock impedance matching method. The experimental data shows that the slope of experimental Hugoniot curve of liquid argon begins to decrease above 30 GPa.

  20. Calculation of ion energy distributions of argon excimer ions generated in helicon plasma

    Institute of Scientific and Technical Information of China (English)

    Fang Tong-Zhen; Jiang Nan; Wang Long

    2005-01-01

    A program is developed to calculate the ion energy distributions (IEDs) of Ar2+ making use of a simplified kinetic model with a combination of Monte Carlo method. Several coefficients are used to realize good match between the calculated and measured results. Some important assumptions are confirmed: argon excimer ions have short lifetime,hence they are formed in a short range before the collecting electrode. The excimer ions that encounter collisions will be discarded because they turn to other ion species after they collide with argon atoms. From the calculated results some plasma parameters such as the cross section or neutral density in discharge could be evaluated.