WorldWideScience

Sample records for argayash cogeneration plant

  1. Performance evaluation of cogeneration power plants

    International Nuclear Information System (INIS)

    Bacone, M.

    2001-01-01

    The free market has changed the criteria for measuring the cogeneration plant performances. Further at the technical-economic parameters, are considered other connected at the profits of the power plant [it

  2. Cogeneration

    International Nuclear Information System (INIS)

    Derbentli, Taner

    2006-01-01

    Cogeneration is the combined production of power and heat. Cogeneration aims to utilize the waste heat of power plants. The waste heat may be utilized for process heating, district heating, drying and cooling. In this way the primary energy is utilized more efficiently. Furthermore due to use of lesser amounts of fuel, emissions and carbon dioxide production is reduced. This is important from the viewpoint of controlling global warming. Cogeneration is used worldwide in industry and in conjunction with district heating.The prime movers used for this purpose are gas turbines, Diesel or natural gas engines and steam power plants. There are several parameters used for characterizing cogeneration. First of all capacity shows the power produced by the cogeneration plant. Most of the cogeneration plants used in industry have capacities between 3 and 20 MW. However there are plants having capacities as large as 200 MW and capacities smaller than 1 MW. The latter are known as micro cogeneration plants. Power to heat ratio is another parameter characterizing cogeneration. It gives the ratio of power produced to heat produced in a cogeneration plant. For gas turbine plants this is around 0.6, for gas engines it is about 1. For steam power plants, power to heat ratio is smaller than 0.4. The total efficiency or fuel utilization efficiency is defined as the total useful output of the plant as power and heat to energy input as fuel. The higher this value, the better is the cogeneration application. In a well designed plant this value may be as high as eighty to ninety percent. Cogeneration started as self power production in Turkey to provide continuous and top quality electric power to industrial plants in the 1990s. Now approximately 20 % of the power production capacity of Turkey is provided by the cogeneration plants. Turkey imports most of its primary energy demand, therefore it is important to increase the use of cogeneration to reduce the demand. There are studies which

  3. Cogeneration plant noise: Environmental impacts and abatement

    International Nuclear Information System (INIS)

    De Renzio, M.; Ciocca, B.

    1991-01-01

    In Italy, ever increasing attention to environmental problems has led to legislation requiring cogeneration plant owners to perform environmental impact assessments in order to determine plant conformity with pollution laws. This paper, based on an in-depth analysis of physics fundamentals relevant to the nature and effects of noise, examines the principal sources of noise in industrial cogeneration plants and the intensity and range of the effects of this noise on the local environment. A review is then made of the different methods of noise pollution abatement (e.g., heat and corrosion resistant silencers for gas turbines, varying types and thicknesses of acoustic insulation placed in specific locations) that can be effectively applied to cogeneration plant equipment and housing

  4. GE will finance 614-MW cogeneration plant

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The General Electric Power Funding Corporation, a unit of GE Capital, will provide up to $870 million in construction and permanent financing, and letters of credit to Cogen Technologies of Houston, Texas. The agreement will fund the construction of a 614-megawatt (MW), combined-cycle cogeneration plant to be built in Linden, New Jersey, and for the purchase of gas properties. The plant will be owned by Cogen Technologies. The financing is one of the largest packages ever for a cogeneration plant, GE said

  5. Cogeneration plants in Italy: Licensing aspects

    International Nuclear Information System (INIS)

    Buscaglione, A.

    1991-01-01

    This paper focusses on administrative/bureaucratic problems relative to the licensing of cogeneration plants in Italy. The current stumbling block appears to lie in organizational difficulties relative to the coordination of various Government authorized safety committees responsible for the drafting up of suitable legislation governing cogeneration plant fire safety aspects. The author cites the possible environmental benefits in terms of air pollution abatement that could have been had with the timely start-up of a new 7 MW plant (in Lombardia) still awaiting its go-ahead authorization

  6. Procedure for cogeneration plant evaluation in Italy

    International Nuclear Information System (INIS)

    Bollettini, U.; Savelli, D.

    1992-01-01

    This paper develops a step-by-step approach to the evaluation of cogeneration plants for on-site power generation. The aim is to allow prospective cogeneration plant owners to build energy/cost efficient plants and to be able to make a proper assessment of eligible financial assistance which may be obtained through the provisions of energy conservation normatives and laws set up by the Italian National Energy Plan. The approach has three principal phases - the verification of the availability of the required human resources able to perform the plant evaluation (engineering, legal and business consultants), an energy/viability audit of any existing energy plant considered for retrofitting and, finally, the identification of the best technical/economic cogeneration alternative. The programmed set of evaluation tasks includes the determination of optimal contracts with ENEL (the Italian National Electricity Board), especially for the case of excess power to be ceded to the national grid, and the making of comparisons with reference cogeneration systems whose relative design/cost data are stored in existing computerized data bases

  7. Cogeneration plants: SNAM (Italy) initiatives and incentives

    International Nuclear Information System (INIS)

    Pipparelli, M.

    1991-01-01

    First, an overall picture is presented of the extension of the use of cogeneration by the Italian brick industry. The particular suitability and usefulness of this form of energy to the brick industry are pointed out. Then a look is given at the legal and financial incentives which have been built into the National Energy Plan to encourage on-site production by Italian industries. Finally, a review is made of initiatives made by SNAM (the Italian National Methane Distribution Society) to develop a favourable tariff structure for on-site power producers using methane as their energy source, as well as, of the Society's efforts to set up a cogeneration equipment consulting service which would provide advice on cogeneration plant design, operation and maintenance

  8. EXERGETIC ANALYSIS OF A COGENERATION POWER PLANT

    Directory of Open Access Journals (Sweden)

    Osvaldo Manuel Nuñez Bosch

    2016-07-01

    Full Text Available Cogeneration power plants connected to industrial processes have a direct impact on the overall efficiency of the plant and therefore on the economic results. Any modification to the thermal outline of these plants must first include an exergetic analysis to compare the benefits it can bring the new proposal. This research is performed to a cogeneration plant in operation with an installed electrical capacity of 24 MW and process heat demand of 190 MW, it shows a study made from the Second Law of Thermodynamics. Exergetic evaluation of each component of the plant was applied and similarly modified cogeneration scheme was evaluated. The results illustrate that the exergy losses and irreversibilities are completely different from one subsystem to another. In general, the total exergy destruction represented 70,7% from the primary fuel exergy. Steam generator was the subsystem with the highest irreversibility of the plant with 54%. It was demonstrated that the increase of the steam parameters lead to reduce exergy destruction and exergy efficiency elevation. The suppression of the reduction system and the adding of an extraction-condensing steam turbine produce the same effect and contribute to drop off the electrical consumption from the grid.

  9. Cogeneration steam turbine plant for district heating of Berovo (Macedonia)

    International Nuclear Information System (INIS)

    Armenski, Slave; Dimitrov, Konstantin

    2000-01-01

    A plant for combined heat and electric power production, for central heating of the town Berovo (Macedonia) is proposed. The common reason to use a co-generation unit is the energy efficiency and a significant reduction of environmental pollution. A coal dust fraction from B rik' - Berovo coal mine is the main energy resource for cogeneration steam turbine plant. The heat consumption of town Berovo is analyzed and determined. Based on the energy consumption of a whole power plant, e. i. the plant for combined and simultaneous production of power is proposed. All necessary facilities of cogeneration plant is examined and determined. For proposed cogeneration steam turbine power plant for combined heat and electric production it is determined: heat and electric capacity of the plant, annually heat and electrical quantity production and annually coal consumption, the total investment of the plant, the price of both heat and electric energy as well as the pay back period. (Authors)

  10. Analysis of carbon dioxide emission of gas fuelled cogeneration plant

    Science.gov (United States)

    Nordin, Adzuieen; Amin, M.; Majid, A.

    2013-12-01

    Gas turbines are widely used for power generation. In cogeneration system, the gas turbine generates electricity and the exhaust heat from the gas turbine is used to generate steam or chilled water. Besides enhancing the efficiency of the system, the process assists in reducing the emission of CO2 to the environment. This study analyzes the amount of CO2 emission by Universiti Teknologi Petronas gas fuelled cogeneration system using energy balance equations. The results indicate that the cogeneration system reduces the CO2 emission to the environment by 60%. This finding could encourage the power plant owners to install heat recovery systems to their respective plants.

  11. Current experience with central-station nuclear cogeneration plants

    International Nuclear Information System (INIS)

    1981-10-01

    In considering the potential of the HTGR for nuclear cogeneration, a logical element for investigation is the recent history of nuclear cogeneration experience. Little is found in recent literature; however, the twin nuclear cogeneration plant at Midland is nearing completion and this milestone will no doubt be the basis for a number of reports on the unique cogeneration facility and operating experiences with it. Less well known in the US is the Bruce Nuclear Power Development in Ontario, Canada. Originally designed to cogenerate steam for heavy water production, the Bruce facility is the focus of a major initiative to create an energy park on the shores of Lake Huron. To obtain an improved understanding of the status and implications of current nuclear cogeneration experience, GCRA representatives visited the Ontario Hydro offices in Toronto and subsequently toured the Midland site near Midland, Michigan. The primary purpose of this report is to summarize the results of those visits and to develop a series of conclusions regarding the implications for HTGR cogeneration concepts

  12. Environmental licensing issues for cogeneration plants

    International Nuclear Information System (INIS)

    Lipka, G.S.; Bibbo, R.V.

    1990-01-01

    The siting and licensing of cogeneration and independent power production (IPP) facilities is a complex process involving a number of interrelated engineering, economic, and environmental impact considerations. Important considerations for the siting and licensing of such facilities include air quality control and air quality impacts, water supply and wastewater disposal, and applicable noise criteria and noise impact considerations. Air quality control and air quality impact considerations for power generation facilities are commonly reviewed in the public forum, and most project developers are generally aware of the key air quality licensing issues. These issues include Best Available Control Technology (BACT) demonstration requirements, and air quality modeling requirements. BACT is a case-by-case determination, which causes uncertainty, in that developers have difficulty in projecting the cost of required control systems. Continuing developments in control technology may cause this problem to continue in the 1990's. Air quality modeling can be a problem in hilly terrain or within or near an urban environment, which could delay or preclude permitting of a new cogeneration or IPP facility in such locations. This paper discusses several environmental issues which are less frequently addressed than air quality issues, namely water/wastewater and noise. The design features of typical cogeneration and IPP facilities that affect water supply requirements, wastewater volumes, and noise emissions are discussed. Then, the site selection and impact review process are examined to identify typical constraints and trade-offs that can develop relative to water, wastewater, and noise issues. Trends in permit review requirements for water, wastewater, and noise are examined. Finally, innovative approaches that can be used to resolve potential development constraints for water, wastewater, and noise issues are discussed

  13. Operating experience with a flexible cogeneration plant in Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Wadman, B.

    1997-01-01

    Much has been written about the interesting gas turbine cogeneration Project in Fort Lupton, Colorado, U.S.A., as created and developed by the Thermo Cogeneration Partnership under the leadership of Paul Steinway, project general manager. The plant is based on five 40 MW-class gas turbine generator modules supplied by Stewart & Stevenson, who is also responsible for operation and maintenance of the plant through its operating arm, Stewart & Stevenson Operations, Inc. The plant, first placed into service in mid-1994 after only 18 months of construction, is of particular interest because it has to function with a wide degree of flexibility in load management, and it also uses one of the latest-design aeroderivative gas turbines, namely the GE LM6000. This article describes the plant design, equipment and operating experience thus far. 6 figs.

  14. Firing with wood chips in heating and cogeneration plants

    International Nuclear Information System (INIS)

    Kofman, P.D.

    1992-01-01

    The document was produced for use as detailed teaching material aimed at spreading information on the use of wood chips as fuel for heating and cogeneration plants. It includes information and articles on wood fuels generally, combustion values, chopping machines, suppliers, occupational health hazards connected with the handling of wood chips, measuring amounts, the selection of types, prices, ash, environmental aspects and information on the establishment of a wood-chip fired district heating plant. (AB)

  15. Thermoeconomic analysis of a power/water cogeneration plant

    International Nuclear Information System (INIS)

    Hamed, Osman A.; Al-Washmi, Hamed A.; Al-Otaibi, Holayil A.

    2006-01-01

    Cogeneration plants for simultaneous production of water and electricity are widely used in the Arabian Gulf region. They have proven to be more thermodynamically efficient and economically feasible than single purpose power generation and water production plants. Yet, there is no standard or universally applied methodology for determining unit cost of electric power generation and desalinated water production by dual purpose plants. A comprehensive literature survey to critically assess and evaluate different methods for cost application in power/water cogeneration plants is reported in this paper. Based on this analysis, an in-depth thermoeconomic study is carried out on a selected power/water cogeneration plant that employs a regenerative Rankine cycle. The system incorporates a boiler, back pressure turbine (supplying steam to two MSF distillers), a deaerator and two feed water heaters. The turbine generation is rated at 118 MW, while MSF distiller is rated at 7.7 MIGD at a top brine temperature of 105 deg. C. An appropriate costing procedure based on the available energy accounting method which divides benefits of the cogeneration configuration equitably between electricity generation and water production is used to determine the unit costs of electricity and water. Capital charges of common equipment such as the boiler, deaerator and feed water heaters as well as boiler fuel costs are distributed between power generated and desalinated water according to available energy consumption of the major subsystems. A detailed sensitivity analysis was performed to examine the impact of the variation of fuel cost, load and availability factors in addition to capital recovery factor on electricity and water production costs

  16. Cogeneration plant to be constructed using CFBC technology

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    A circulating fluidized bed (CFB) combustion technology will be used in a cogeneration plant to be constructed in western Pennsylvania by Air Products and Chemicals, Inc., of Allentown, Pennsylvania. The plant will burn bituminous waste coal in two CFB boilers. A 30-year supply of fuel for the plant will be obtained from a 30-million-ton waste coal pile adjacent to the site and from another smaller pile in the area. Ash resulting from the combustion process will be returned to the acidic waste coal piles to aid in their reclamation, Air Products said

  17. Small Nuclear Co-generation Plants Based on Shipbuilding Technology

    International Nuclear Information System (INIS)

    Vasyukov, V. I.; Veshnyakov, K. B.; Goryunov, E. V.; Zalugin, V. I.; Panov, Yu. K.; Polunichev, V. I.

    2002-01-01

    The development of nuclear cogeneration plants and power desalination complexes of relatively small power, using proven shipbuilding technology, becomes more and more attractive for solving the power supply problems of remote districts of the Extreme North and the Far East with small and medium power grids and for removing the shortage of fresh water in different world regions. The idea of transportation of the power unit with high degree of readiness to the place of its location with minimum construction and mounting activities at the site is very attractive. Compactness typical of RP based on shipbuilding technology allows to develop floating or ground-based plants at minimum use of water area and territory. Small construction scope at the site under conditions of minimum anthropogenic loads and high ecological indices are important arguments in favor of floating nuclear cogeneration plant based on ship power units against the alternative fossil sources. At present, the activities on floating nuclear cogeneration plant design, which is developed on the basis of floating power unit with two KLT-40S reactor plant, which is a modified option of standard KLT-40-type ship plant for icebreaker fleet in Russia are the most advanced. To date, a detailed design of reactor plant has been developed and approved, design activities on floating power unit are in the stage of completion, the site for its location has been selected and licensing by GAN, Russia, is in progress. Besides OKBM has developed some designs of nuclear cogeneration plants of different power on the basis of integral reactor plants, using the experience of transport and stationary power plants designing. Nuclear cogeneration plant investment analysis showed acceptable social and economical efficiency of the design that creates conditions for commercial construction of floating power units with KLT-40S reactor plan. At the same time the reduction of the design recovering terms, increase of budget income and

  18. Electric power plants in cogeneration: a promising potential even in France

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    Implantation of cogeneration power plants has increased in France since two years but stays below other countries such as northern Europe. Technical, economical, legal and financial aspects of cogeneration have been debated during the ''Euroforum'' seminar (June 14-16, 1995). The european association Cogen Europe, created in 1993 with the financial support of the SAVE european program, has analysed the barriers that restrain cogeneration development and their solutions. Advantages of cogeneration are undeniable at any scale (from small engines to huge industrial systems) if efficiency of energy used reaches 85%. Opinions of representatives from different industries implied in cogeneration technology are reported. (J.S.). 1 photo

  19. Modern fluidized bed combustion in Ostrava-Karvina cogeneration plants

    Energy Technology Data Exchange (ETDEWEB)

    Mazac, V. [Energoprojekt Praha, Ostrava (Czechoslovakia); Novacek, A. [Moravskoslezske teplamy, Ostrava (Czechoslovakia); Volny, J. [Templamy Karvina (Czechoslovakia)

    1995-12-01

    The contemporary situation of our environment claims the sensitive approach to solving effective conversion of energy. Limited supplies of noble fuels and their prices evoke the need to use new combustion technologies of accessible fuels in given region without negative ecological influences. Energoproject participates in the preparation of the two projects in Ostrava-Karvin{acute a} black coal field in Czech Republic. The most effective usage of fuel energy is the combined of electricity and heat. If this physical principle is supported by a pressurized fluidized bed combustion (PFBC) one obtains a high electricity/heat ratio integrated steam-gas cycle on the basis of solid fuel. Cogeneration plant Toebovice is the dominant source (600 MW{sub th}) of Ostrava district heating system (1100 MW{sub th}). The high utilization of the installed output and utilization of the clean, compact and efficient of the PFBC technology is the principal but not the single reason for the selection of the Toebovice power plant as the first cogeneration plant for installation of the PFBC in Czech Republic. The boiler will burn black coal from the neighboring coal basin.

  20. Studies on Steam Absorption Chillers Performance at a Cogeneration Plant

    Directory of Open Access Journals (Sweden)

    Abd Majid Mohd Amin

    2014-07-01

    Full Text Available Absorption chillers at cogeneration plants generate chilled water using steam supplied by heat recovery steam generators. The chillers can be of either single-effect or double effect configuration and the coefficient of performance (COP depends on the selection made. The COP varies from 0.7 to 1.2 depending on the types of chillers. Single effect chillers normally have COP in the range of 0.68 to 0.79. Double effect chillers COP are higher and can reach 1.2. However due to factors such as inappropriate operations and maintenance practices, COP could drop over a period of time. In this work the performances of double effect steam absorption chillers at a cogeneration plant were studied. The study revealed that during the period of eleven years of operation the COP of the chillers deteriorated from 1.25 to 0.6. Regression models on the operation data indicated that the state of deterioration was projected to persist. Hence, it would be recommended that the chillers be considered for replacement since they had already undergone a series of costly repairs.

  1. Tax treatment of cogeneration plants; Steuerliche Behandlung von Blockheizkraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Richter, Niklas; Haats, Jochen [Becker Buettner Held, Muenchen (Germany)

    2011-06-14

    In a BMF letter dated from 14th March, 2011 (IV D 2 - S 7124/07/10002), the fiscal authority has used the decision of the Federal Fiscal Court (Munich, Federal Republic of Germany) from 18th December, 2008 (V R 80/07) as an opportunity to pronounce a business activity, the pre-tax deduction and assessment basis of the free withdrawal in the operation of combined heat and power plants (CHP plants) and in particular of cogeneration (CHP). In addition to the VAT treatment, the income tax treatment of CHP as amended by Financial Management has changed due to the majority decision of the director of the income tax department of the federal and state governments in 2010.

  2. Study of a cogeneration plant for agro-food industry

    Energy Technology Data Exchange (ETDEWEB)

    Fantozzi, Francesco; Ferico, Sandro Diaconi; Desideri, Umberto [Universita di Perugia, Dipt. di Ingegneria Industriale, Perugia (Italy)

    2000-08-01

    A technical and economic feasibility study for a natural gas fueled cogeneration plant was conducted in an important Italian pasta and animal feed factory. The layout analysis pointed out three main divisions; in each division electric and thermal users were pointed out and their effective energy consumption and power demand rate was monitored. A technical feasibility analysis was then carried out to determine the type and scale of the possible Combined Heat and Power (CHP) plants focusing on Internal Combustion Engines (ICEs) and gas turbine based power plants. The actual energy costs were evaluated on the base of the energy bills for the biennium 1996-97 while the detailed economic feasibility analysis was conducted on the base of the offers received from manufacturers on the market. The results obtained show the possibility to have low payback periods and appealing internal rate of returns when investing on ICEs based CHP plants covering the entire electric demand and partially fulfilling the thermal needs of the factory. (Author)

  3. The operation of small cogeneration plants and short-term storage for district heating and public electric power

    DEFF Research Database (Denmark)

    Ilkjær, J; Petersen, P.M.; Qvale, Einar Bjørn

    1989-01-01

    A theoretical investigation of the economics of cogeneration supplemented by warm-water storage and subjected to a three-step price schedule for electricity, has been carried out. Some general guidelines can be derived, but no simple design rules, such as those for cogeneration plants operating...... of cogeneration plant size relative to the total heat demand in the geographical region supplied by the plant are shown...

  4. Energy cogeneration in urban sewage treatment plants; Cogeneracion energetica en depuradoras de aguas residuales urbanas

    Energy Technology Data Exchange (ETDEWEB)

    Cazurra Perez, T.

    1997-04-01

    The management of the sludge it produces is a decisive element in designing and urban waste water treatment plant. For a single plant, or several plants that are geographically close together heat-drying the sludge is a viable post-treatment for joint sludge productions of 18,000 tons per year which is the equivalent of a 40,000 m``3/day treatment flow. Energy cogeneration substantially cuts the cost of providing the heat required, enabling the total cost of drying the sludge to be reduced by 40% and creating additional economic benefits. This makes the thermal drying/cogeneration combination and attractive proposition. (Author)

  5. Feasibility study of a biomass-fired cogeneration plant Groningen, Netherlands

    International Nuclear Information System (INIS)

    Rijk, P.J.; Van Loo, S.; Webb, R.

    1996-06-01

    The feasibility of the title plant is determined for district heating and electricity supply of more than 1,000 houses in Groningen, Netherlands. Also attention is paid to the feasibility of such installations in a planned area of the city. Prices and supply of several biomass resources are dealt with: prunings of parks, public and private gardens, clean wood wastes, wood wastes from forests, wood from newly planted forests, specific energy crops (willows in high densities and short cycles). Prices are calculated, including transport to the gate of the premises where the cogeneration installations is situated. For the conversion attention is paid to both the feasibility of the use of a conventional cogeneration installation (by means of a steam turbine) and the use of a new conversion technique: combined cycle of a gasification installation and a cogeneration installation. 5 figs., 5 ills., 22 tabs., 1 appendix, 33 refs

  6. Evaluation of Redundancy for Power Generating Unit in a Cogeneration Power Plant

    Directory of Open Access Journals (Sweden)

    Reshid Meseret Nasir

    2014-07-01

    Full Text Available Redundancy system is very useful to enhance the performance and reliability of the power generation system of a cogeneration plant. However, the associated operating cost of redundancy system is very high. The common redundancies used in a cogeneration power plant are public utility and generator set. In order to select the best redundancy options which incurs minimum operating cost, it is required to evaluate the cost of different redundancy options. In this paper, net present value model (NPV is developed to evaluate the cost of redundancy considering availability and reliability of the cogeneration system. Two steps applied to evaluate the redundancy cost of the cogeneration system. The first step is predicting the number of failures and downtime hours using availability and reliability analysis because redundancy is frequently used when the system failed. The second step is evaluating the cost of redundancy using NPV model. The results indicate that the use of public utility as redundancy option is costly compared to generator set option for long period of time. The major operation cost of public utility is contributed by the maximum demand charge cost which is about 57.9% of the total cost of redundancy. The study will be useful as a guide for the cogeneration operation to evaluate and select the redundancy option.

  7. Flexibility and uncertainty in agribusiness projects: investing in a cogeneration plant.

    Directory of Open Access Journals (Sweden)

    Augusto Cesar Arenaro e Mello Dias

    2011-08-01

    Full Text Available Energy generation from biomass has become a source of increasing interest due to growing environmental concerns and the depletion of the world’s fossil fuel reserves. In this paper we analyze a sugar and ethanol producing plant in Brazil which has both the option to expand and to add a cogeneration unit to allow the sale of surplus energy, generated by burning sugar cane bagasse, where the existence of the second option is conditional to the exercise of the first option. We model sugar, ethanol, and electricity prices as geometric mean reverting processes and apply the real options approach to determine the value of these managerial flexibilities, considering that these options have three distinct underlying assets. The option to expand production is a function of the expected future prices of sugar and ethanol, while, on the other hand, the decision to invest in the cogeneration plant will depend on the future prices of energy. Both decisions are modeled as American Compound Options over their respective underlying assets. The model is then solved using the non-censored binomial mean reverting lattice proposed by Bastian-Pinto, Brandão, and Hahn (2010 using the software DPLTM. The results indicate that a significant value can be derived from the flexibility to choose the optimal timing of investment in both options: the investment in the cogeneration unit adds an amount equivalent to the value of the expanding sugar and ethanol production, and represents up to 44% of the project’s static NPV of R$ 195.9 million. We conclude that given that only half of the sugar cane crushing mills currently have cogeneration units installed and given the increasing demand for clean and renewable sources of energy, this may indicate there is a significant potential for investment and further development of bioelectricity cogeneration power plants, and even in the retrofit of older cogeneration units, and that government incentives have been effective in

  8. HTGR-GT closed-cycle gas turbine: a plant concept with inherent cogeneration (power plus heat production) capability

    International Nuclear Information System (INIS)

    McDonald, C.F.

    1980-04-01

    The high-grade sensible heat rejection characteristic of the high-temperature gas-cooled reactor-gas turbine (HTGR-GT) plant is ideally suited to cogeneration. Cogeneration in this nuclear closed-cycle plant could include (1) bottoming Rankine cycle, (2) hot water or process steam production, (3) desalination, and (4) urban and industrial district heating. This paper discusses the HTGR-GT plant thermodynamic cycles, design features, and potential applications for the cogeneration operation modes. This paper concludes that the HTGR-GT plant, which can potentially approach a 50% overall efficiency in a combined cycle mode, can significantly aid national energy goals, particularly resource conservation

  9. Cogeneration. Kraftvaerme

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    Existing and future technologies for cogeneration in the 1-100 MW ranges are reviewed. Efforts have been made to analyze performance and economy of the different plants in a uniform manner. The technologies presented are supposed to represent the normal status at the beginning of the next century. The economy of the plants have been analyzed through sensitivity analysis. Some main conclusions are: the competitiveness of cogeneration has been identified; the taxation principles for energy are of outmost importance; there is no need to await new technology for starting to build cogeneration plants. In a long perspective, R and D effort should be concentrated on combustion of solid fuels in diesel engines and gas turbines, and on molten carbonate fuel cells. (L.E.).

  10. Public health impact assessment of a proposed cogeneration plant in the Quebec city metropolitan area

    Energy Technology Data Exchange (ETDEWEB)

    Lajoie, P.; Bolduc, D.; Gauvin, D.; Guerrier, P.; Gauthier, R. [Quebec Public Health Center, Ste-Foy (Canada); Laflamme, P. [Laval Univ. (Canada). Dept. of Preventive Medicine

    1995-12-31

    In 1994, public hearings were held in Quebec city concerning a 120 megawatt (MW) gas cogeneration project that was to be coupled with an already existing pulp and paper mill in the downtown area. Cogeneration plants are often described as highly beneficial from the point of view of local environment. It is well known that the burning of natural gas emits far less sulfur dioxide (SO{sub 2}) and particulate matters (PM) than the combustion of oil or coal. The proposed plant would use high pressure vapour from a nearby incinerator plant and natural gas to produce low pressure vapor for the paper mill industry as well as electricity. The cogeneration plant would allow the paper mill to stop burning heavy oil. By using natural gas instead of heavy oil, the new cogeneration-paper mill complex (CPC) is expected to reinforce the recent trend and willingness towards improving downtown air quality. On the other hand, the CPC would emit more CO{sub 2}, due to the production of additional electricity. According to the Rio de Janeiro Agreement ratified in 1988, Canada is committed to stabilize its greenhouse gas emissions by the year 2000. Nevertheless, the cogeneration file is a new option considered by the Quebec Provincial Governement in its last energy triennal plan. However, it must be specified that the Province of Quebec contributes to less than 15 % of the total Canadian CO{sub 2} production although it represents more than 25 % of its population. Furthermore the maximum production of electricity by this file has been set to 250 MW. It is a very small fraction of the total production of electricity in Quebec, which is 200 TW

  11. Evaluation of a Cogeneration Plant with Integrated Fuel Factory; Integrerad braenslefabrik med kraftvaermeanlaeggning - en utvaerdering

    Energy Technology Data Exchange (ETDEWEB)

    Atterhem, Lars

    2002-12-01

    A feasibility study was carried out in 1993 by Skellefteaa Kraft AB, to analyse the technical and economical possibilities to build a new baseload district heating production plant. The conclusion from the study was that, as a first step, a new cogeneration plant, based on a circulating fluidised bed boiler, should be built. The commissioning of the cogeneration plant took place in autumn 1996. The plant was prepared for a future integration with a biofuel drying process for pellets production. During spring 1996 an investment decision was taken and the fuel factory was erected in may 1997. Vaermeforsk Service AB has financed this research project and the Swedish state energy program (Fabel) has contributed with 33,7 Million SEK to the financing of the recovery electric power generation part of the fuel factory. The aim with this research project has been to evaluate and compare the integrated cogeneration plant fuel factory concept with a conventional co-generation plant, specially when it comes to increased power generation. The fuel factory comprises of fuel feeding system, fuel dryer, steam converter from fuel moisture to low pressure process steam, low pressure condensing turbine, cooling water system, fuel pellets production and storage with ship loading plant in the harbour of Skellefteaa. The steam to the fuel factory is extracted from the cogeneration turbine at a pressure level between 12-26 bar and the extraction flow has then already generated power in the cogeneration turbine. Power is also generated in the low pressure condensing turbine of the fuel factory. The low pressure steam is generated with fuel moisture in the steam converter. During the first years of operation there has been both conventional commissioning problems but also technical problems related to the new process concept. The last are for example corrosion and erosion problems, fouling problems of heat exchangers, capacity and leakage problems. The performance goals of the fuel

  12. Analysis of combustion turbine inlet air cooling systems applied to an operating cogeneration power plant

    International Nuclear Information System (INIS)

    Chacartegui, R.; Jimenez-Espadafor, F.; Sanchez, D.; Sanchez, T.

    2008-01-01

    In this work, combustion turbine inlet air cooling (CTIAC) systems are analyzed from an economic outlook, their effects on the global performance parameters and the economic results of the power plant. The study has been carried out on a combined cogeneration system, composed of a General Electric PG 6541 gas turbine and a heat recovery steam generator. The work has been divided into three parts. First, a revision of the present CTIAC technologies is shown, their effects on power plant performance and evaluation of the associated investment and maintenance costs. In a second phase of the work, the cogeneration plant was modelled with the objective of evaluating the power increase and the effects on the generated steam and the thermal oil. The cogeneration power plant model was developed, departing from the recorded operational data of the plant in 2005 and the gas turbine model offered by General Electric, to take into consideration that, in 2000, the gas turbine had been remodelled and the original performance curves should be corrected. The final objective of this model was to express the power plant main variables as a function of the gas turbine intake temperature, pressure and relative humidity. Finally, this model was applied to analyze the economic interest of different intake cooling systems, in different operative ranges and with different cooling capacities

  13. Modelling the dynamics of the cogeneration power plant gas-air duct

    Directory of Open Access Journals (Sweden)

    Аnatoliy N. Bundyuk

    2014-12-01

    Full Text Available Introducing into wide practice the cogeneration power plants (or CHP is one of promising directions of the Ukrainian small-scale power engineering development. Thermal and electric energy generation using the same fuel kind can increase the overall plant efficiency. That makes it appropriate to use CHPs at compact residential areas, isolated industrial enterprises constituting one complex with staff housing area, at sports complexes, etc. The gas-air duct of the cogeneration power plant has been considered as an object of the diesel-generator shaft velocity control. The developed GAD mathematical model, served to analyze the CHP dynamic characteristics as acceleration curves obtained under different external disturbances in the MathWorks MATLAB environment. According to the electric power generation technology requirements a convenient transition process type has been selected, with subsequent identification of the diesel-generator shaft rotation speed control law.

  14. Starting the water treatment system of the 410-MW combined-cycle plant at the Krasnodar cogeneration station

    Science.gov (United States)

    Panteleev, A. A.; Zhadan, A. V.; Gromov, S. L.; Tropina, D. V.; Arkhipova, O. V.

    2012-07-01

    The process diagram of a water treatment plant constructed on the basis of integrated membrane technologies with the use of two-stage reverse osmosis for the PGU-410 power unit at the Krasnodar cogeneration station is presented.

  15. Thermoeconomic analysis of Biomass Integrated Gasification Gas Turbine Combined Cycle (BIG GT CC) cogeneration plant

    Energy Technology Data Exchange (ETDEWEB)

    Arrieta, Felipe Raul Ponce; Lora, Electo Silva [Escola Federal de Engenharia de Itajuba, MG (Brazil). Nucleo de Estudos de Sistemas Termicos]. E-mails: aponce@iem.efei.br; electo@iem.efei.br; Perez, Silvia Azucena Nebra de [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Energia]. E-mail: sanebra@fem. unicamp.br

    2000-07-01

    Using thermoeconomics as a tool to identify the location and magnitude of the real thermodynamic losses (energy waste, or exergy destruction and exergy losses) it is possible to assess the production costs of each product (electric power and heat) and the exergetic and exergoeconomic cost of each flow in a cogeneration plant to assist in decision-marketing procedures concerning to plant design, investment, operation and allocations of research funds. Thermo economic analysis of Biomass Integrated Gasification Gas Turbine Combined Cycle (BIG GT CC) cogeneration plant for its applications in sugar cane mills brings the following results: the global exergetic efficiency is low; the highest irreversibilities occur in the following equipment, by order: scrubber (38%), gas turbine (16%), dryer (12%), gasifier and HRSG (6%); due to the adopted cost distribution methodology, the unit exergetic cost of the heat (4,11) is lower than electricity (4,71); the lower market price of biomass is one of the most sensible parameter in the possible implementation of BIG-GT technology in sugar cane industry; the production costs are 31 US$/MWh and 32 US$/MWh for electricity and heat, respectively. The electricity cost is, after all, competitive with the actual market price. The electricity and heat costs are lower or almost equal than other values reported for actual Rankine cycle cogeneration plants. (author)

  16. Modeling and simulation of cogeneration nuclear power plant for seawater desalination

    Energy Technology Data Exchange (ETDEWEB)

    Asiedu-Boateng, P., E-mail: pierob79@yahoo.co.uk [Department of Nuclear Engineering and Material Science, School of Nuclear and Allied Sciences (SNAS), University of Ghana, P.O. Box AE1, Atomic Energy, Accra (Ghana); Akaho, E.H.K. [Department of Nuclear Engineering and Material Science, School of Nuclear and Allied Sciences (SNAS), University of Ghana, P.O. Box AE1, Atomic Energy, Accra (Ghana); Nyarko, B.J.B.; Yamoah, S. [National Nuclear Research Institute, Ghana Atomic Energy Commission, P.O. Box LG80, Legon (Ghana)

    2012-01-15

    Nuclear desalination of seawater remains a very viable option to solving the perennial fresh water shortage problem along the coast of Ghana especially as Ghana prepares to install the first nuclear power plant. There is, therefore, the need for research to be conducted into nuclear seawater desalination technology as part of the nuclear power program of Ghana so as to develop the needed human resources in Ghana. In this research, cycle analysis of the cogeneration nuclear power plant was conducted to determine its efficiency and desalination steam requirements. An analytical model of the thermo vapour compression (TVC) desalination process was also developed to investigate the effect of design and operating parameters on parameters controlling the cost of producing fresh water from TVC process. Steady state mass and energy balances as well as empirical correlations derived from experiments were used to model the TVC, which was coupled to a cogeneration nuclear power plant to supply the needed steam for the desalination. The model was developed on a computer code, using FORTRAN language. The results showed that the thermal performance of the TVC desalination process improves with the efficiency of the cogeneration nuclear power plant but decreases with increasing steam consumption rates.

  17. Cogeneration in air separation cryogenic plants; Cogeracao em plantas criogenicas de separacao de ar

    Energy Technology Data Exchange (ETDEWEB)

    Bastos, Walter N.; Orlando, Alcir F. [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica]. E-mails: wnovellob@openlink.com.br; afo@mec-puc-rio.br

    2000-07-01

    A thermal and economic study, carried on by using the first and second law of thermodynamics concepts demonstrated the economic feasibility of the cogeneration system, and proposed modifications to be done in the studied cryogenic plant, a typical T-240 NA MPL3 plant. The thermodynamic analysis showed that the second law efficiency of the processes could be improved, together with a 12% electric energy consumption reduction. Four cogeneration schemes were analyzed with both the first and second laws of thermodynamics and, then, the economic analysis was performed. Rankine, Brayton, Otto and Combined gas-steam basic cycles were used in this analysis.The combined gas-steam cycle was shown to be more economically feasible than others. Thermal and electric loads were well balanced, resulting in a higher second law efficiency. Although the initial investment for the modification was higher, the savings resulted to be higher, turning into a higher rate of return of the investment. (author)

  18. Scheduling of cogeneration plants considering electricity wheeling using enhanced immune algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Sungling Chen; Mingtong Tsay; Hongjey Gow [Cheng-Shiu Univ., Dept. of Electrical Engineering, Kaohsiung (Taiwan)

    2005-01-01

    A new method based on immune algorithm (IA) is presented to solve the scheduling of cogeneration plants in a deregulated market. The objective function includes fuel cost, population cost, and electricity wheeling cost, subjective to the use of mixed fuels, operational limits, emissions constraints, and transmission line flow constraints. Enhanced immune algorithm (EIA) is proposed by an improved crossover and mutation mechanism with a competition and auto-adjust scheme to avoid prematurity. Table lists with heuristic rules are also employed in the searching process to enhance the performance. EIA is also compared with the original IA. Test results verify that EIA can offer an efficient way for cogeneration plants to solve the problem of economic dispatch, environmental protection, and electricity wheeling. (Author)

  19. ASEAN grid-connected biomass residues fired cogeneration plants

    International Nuclear Information System (INIS)

    Adnan, M.F.; Alias, R.

    2006-01-01

    Energy supply is one of the major concerns in the world. With uncertainty in the main oil suppliers, the oil price is expected to remain high due to continuous demand from the world. Since oil is mostly used for electricity and transportation, its shortage would cause major disruptions in our daily activities. Thus to counter this scenario and faster depletion of fossil fuel resources, various measures have been taken to find alternative source of energy such as renewable energy. One of the renewable energy sources is from biomass residues which is aplenty particularly in ASEAN. Through one of the collaboration programme between ASEAN and EC which is The EC-ASEAN Cogeneration Programme, a number of Full-Scale Demonstration Projects (FSDP) using biomass residues have been commissioned and implemented successfully. Four of the FSDPs in Thailand and Malaysia are connected to the grid. These projects have been operating very well and since the fuel is commonly available in this ASEAN region, duplication should not be a problem. Thus, this paper would highlight the success stories in implementing biomass residues grid connected project while enhancing cooperation between ASEAN and EC. (Author)

  20. Efficiency Growth of Combined-cycle Cogeneration Plant with the Heat Supply System

    Directory of Open Access Journals (Sweden)

    Denysova Alla

    2015-08-01

    Full Text Available Energy efficiency of modern technologies of the combined production of heat and electricity and ways of energy saving on base of recycling secondary energy sources has been estimated. It is shown that the most effective for cogeneration are combined-cycle plants. The rational scheme of interaction of combined-cycle cogeneration plant with heat supply system has been offered. Theoretical bases of interaction of main installation with a contour of heat and hot water supply system has been developed. Numerical modeling of temperature parameters and the analysis of results of numerical modeling has been executed. The technology of increase of energy efficiency of installations on base of recycling heat is offered. Increase of effectiveness of system is achieved due to full use of heat and reduction of losses to environment. It is established, that the rational scheme of interaction of combined-cycle cogeneration plant with heat supply system allows increasing energy efficiency on 2 % that corresponds to economy of fuel 3 %.

  1. Comparative analysis of cogeneration power plants optimization based on stochastic method using superstructure and process simulator

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Leonardo Rodrigues de [Instituto Federal do Espirito Santo, Vitoria, ES (Brazil)], E-mail: leoaraujo@ifes.edu.br; Donatelli, Joao Luiz Marcon [Universidade Federal do Espirito Santo (UFES), Vitoria, ES (Brazil)], E-mail: joaoluiz@npd.ufes.br; Silva, Edmar Alino da Cruz [Instituto Tecnologico de Aeronautica (ITA/CTA), Sao Jose dos Campos, SP (Brazil); Azevedo, Joao Luiz F. [Instituto de Aeronautica e Espaco (CTA/IAE/ALA), Sao Jose dos Campos, SP (Brazil)

    2010-07-01

    Thermal systems are essential in facilities such as thermoelectric plants, cogeneration plants, refrigeration systems and air conditioning, among others, in which much of the energy consumed by humanity is processed. In a world with finite natural sources of fuels and growing energy demand, issues related with thermal system design, such as cost estimative, design complexity, environmental protection and optimization are becoming increasingly important. Therefore the need to understand the mechanisms that degrade energy, improve energy sources use, reduce environmental impacts and also reduce project, operation and maintenance costs. In recent years, a consistent development of procedures and techniques for computational design of thermal systems has occurred. In this context, the fundamental objective of this study is a performance comparative analysis of structural and parametric optimization of a cogeneration system using stochastic methods: genetic algorithm and simulated annealing. This research work uses a superstructure, modelled in a process simulator, IPSEpro of SimTech, in which the appropriate design case studied options are included. Accordingly, the cogeneration system optimal configuration is determined as a consequence of the optimization process, restricted within the configuration options included in the superstructure. The optimization routines are written in MsExcel Visual Basic, in order to work perfectly coupled to the simulator process. At the end of the optimization process, the system optimal configuration, given the characteristics of each specific problem, should be defined. (author)

  2. Evaluation of different hedging strategies for commodity price risks of industrial cogeneration plants

    International Nuclear Information System (INIS)

    Palzer, Andreas; Westner, Günther; Madlener, Reinhard

    2013-01-01

    In this paper, we design and evaluate eight different strategies for hedging commodity price risks of industrial cogeneration plants. Price developments are parameterized based on EEX data from 2008 to 2011. The probability distributions derived are used to determine the value-at-risk (VaR) of the individual strategies, which are in a final step combined in a mean-variance portfolio analysis for determining the most efficient hedging strategy. We find that the strategy adopted can have a marked influence on the remaining price risk. Quarter futures are found to be particularly well suited for reducing market price risk. In contrast, spot trading of CO 2 certificates is found to be preferable compared to forward market trading. Finally, portfolio optimization shows that a mix of various hedging strategies can further improve the profitability of a heat-based cogeneration plant. - Highlights: • Evaluation of commodity price risk hedging strategies for industrial cogeneration. • Value-at-risk analysis of eight different hedging strategies. • Mean-variance portfolio analysis for determining the optimal hedging strategy mix. • A mix of hedging strategies further improves profitability of heat-based CHP

  3. The choice of equipment mix and parameters for HTGR-based nuclear cogeneration plants

    International Nuclear Information System (INIS)

    Malevski, A.L.; Stoliarevski, A.Ya.; Vladimirov, V.T.; Larin, E.A.; Lesnykh, V.V.; Naumov, Yu.V.; Fedotov, I.L.

    1990-01-01

    Improvement of heat and electricity supply systems based on cogeneration is one of the high-priority problems in energy development of the USSR. Fossil fuel consumption for heat supply exceeds now its use for electricity production and amounts to about 30% of the total demands. District heating provides about 80 million t.c.e. of energy resources conserved annually and meets about 50% of heat consumption of the country, including about 30% due to cogeneration. The share of natural gas and liquid fuel in the fuel consumption for district heating is about 70%. The analysis of heat consumption dynamics in individual regions and industrial-urban agglomerations shows the necessity of constructing cogeneration plants with the total capacity of about 60 million kW till the year 2000. However, their construction causes some serious problems. The most important of them are provision of environmentally clean fuels for cogeneration plants and provision of clear air. The limited reserves of oil and natural gas and the growing expenditures on their production require more intensive introduction of nuclear energy in the national energy balance. Possible use of nuclear energy based on light-water reactors for substitution of deficient hydrocarbon fuels is limited by the physical, technical and economic factors and requirements of safety. Further development of nuclear energy in the USSR can be realized on a new technological base with construction of domestic reactors of increased and ultimate safety. The most promising reactors under design are high-temperature gas-cooled reactors (HTGR) of low and medium capacity with the intrinsic property of safety. HTGR of low (about 200-250 MW(th) in a steel vessel), medium (about 500 MW(th) in a steel-concrete vessel) and high (about 1000-2500 MW(th) in a prestressed concrete vessel) are now designed and studied in the country. At outlet helium temperature of 920-1020 K it is possible to create steam turbine installations producing both

  4. Implementation of a cogeneration plant for a food processing facility. A case study

    International Nuclear Information System (INIS)

    Bianco, Vincenzo; De Rosa, Mattia; Scarpa, Federico; Tagliafico, Luca A.

    2016-01-01

    Highlights: • CHP utilization is demonstrated to allow a reduction of primary energy consumption. • The consideration of various investment indexes leads to the determination of different optimal powers. • The choice of a specific investment index to evaluate a CHP is linked to the strategy of the company. - Abstract: The present work presents an investigation regarding the feasibility analysis of a cogeneration plant for a food processing facility with the aim to decrease the cost of energy supply. The monthly electricity and heat consumption profiles are analyzed, in order to understand the consumption profiles, as well as the costs of the current furniture of electricity and gas. Then, a detailed thermodynamic model of the cogeneration cycle is implemented and the investment costs are linked to the thermodynamic variables by means of cost functions. The optimal electricity power of the co-generator is determined with reference to various investment indexes. The analysis highlights that the optimal dimension varies according to the chosen indicator, therefore it is not possible to establish it univocally, but it depends on the financial/economic strategy of the company through the considered investment index.

  5. Load averaging system for co-generation plant; Jikayo hatsuden setsubi ni okeru fuka heijunka system

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Y. [Fuji Electric Co. Ltd., Tokyo (Japan)

    1995-07-30

    MAZDA Motor Corp. planed the construction of a 20.5MW co-generation plant in 1991 for responding to an increase in power demand due to expansion of the Hofu factory. On introduction of this co-generation plant, it was decided that the basic system would adopt the following. (1) A circulating fluidized bed boiler which can be operated by burning multiple kinds of fuels with minimum environmental pollution. (2) A heat accumulation system which can be operated through reception of a constant power from electric power company despite a sudden and wide range change in power demand. (3) A circulating-water exchange heat recovery system which recovers exhaust heat of the turbine plant as the hot water to be utilized for heating and air-conditioning of the factory mainly in winter. Power demand in MAZDA`s Hofu factory changes 15% per minute within a maximum range from 20MW to 8MW. This change is difficult to be followed even by an oil burning boiler excellent in load follow-up. The circulating Fluidized bed boiler employed this time is lower in the follow-up performance than the oil boiler. For the newly schemed plant, however, load averaging system named a heat accumulation system capable of responding fully to the above change has been developed. This co-generation plant satisfied the official inspection before commercial operation according the Ministerial Ordinance in 1993. Since then, with regard to the rapid load following, which was one of the initial targets, operation is now performed steadily. This paper introduces an outline of the system and operation conditions. 10 refs.

  6. Homogeneous groups of plants, development scenarios, and basic configurations on the cogeneration systems optimization from the alcohol sector

    International Nuclear Information System (INIS)

    Silva Walter, A.C. da; Bajay, S.V.; Carrillo, J.L.L.

    1990-01-01

    The evaluation of introducing or diffusing new technologies at a macro economic level using micro economic information can be carried out through the careful selection of a small number of homogeneous groups of plants from the point of view of the main technical parameters being considered. In this paper this concept is applied to the study of cogeneration in sugar and alcohol producing plants. The statistical techniques of Cluster Analysis, regressions and mean value testing are used. Basic cogeneration plant designs are proposed for alternatives development scenarios for this industrial branch. These scenarios are based upon differing assumptions about the expansion of alcohol market, use of surplus sugar cane bagasse as saleable commodity, as a fuel or raw material, and price expectations for the sale of surplus power from the cogeneration plants to the local grid. (author)

  7. Cogeneration in Southeast Asia: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Shakya, S.K. [EC-ASEAN COGEN Programme, Bangkok (Thailand)

    2002-10-01

    This article presents an overview of cogeneration in Brunei, Indonesia, Malaysia, the Philippines, Singapore, Thailand, Vietnam and Cambodia. The status of cogeneration technologies in Southeast Asia is examined, and details are given of some cogeneration projects such as the cogeneration scheme at a new sawmill and moulding factory in Malaysia, and the cogeneration plant at a large rice mill in Thailand. The potential for cogeneration in the region is assessed.

  8. Analysis of energy cogeneration incentive politics to a sodium-chlorine Brazilian chemical plant energy cogeneration; Analise de politicas de incentivo a cogeracao de energia numa planta quimica brasileira de soda-cloro

    Energy Technology Data Exchange (ETDEWEB)

    Bastos, J.B.V.; Borschiver, S. [Universidade Federal do Rio de Janeiro (CT/UFRJ), RJ (Brazil). Centro de Tecnologia], E-mail: suzana@eq.ufrj.br; Szklo, A.S. [Universidade Federal do Rio de Janeiro (PPE/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Planejamento Energetico], E-mail: szklo@ppe.ufrj.br; Andrade, M.H.S. [Braskem S.A., Rio de Janeiro, RJ (Brazil)], E-mail: marcio.andrade@braskem.com.br

    2010-07-01

    This paper evaluates, from a pont of view of investor and through the use of a simulator, the impact of incentive politics to the cogeneration, from the sugar cane bagasse, at a plant for production of sodium-chlorine.

  9. Techno-Economic Assessment of Redundancy Systems for a Cogeneration Plant

    Directory of Open Access Journals (Sweden)

    Majid Mohd Amin Abd

    2014-07-01

    Full Text Available The use of distributed power generation has advantage as well as disadvantage. One of the disadvantages is that the plant requires a dependable redundancy system to provide back up of power during failure of its power generation equipment. This paper presents a study on techno-economic assessment of redundancy systems for a cogeneration plant. Three redundancy systems were investigated; using public utility, generator set and gas turbine as back up during failures. Results from the analysis indicate that using public utility provides technical as well as economic advantages in comparison to using generator set or turbine as back up. However, the economic advantage of the public utility depends on the frequency of failures the plant will experience as well on the maximum demand charge. From the break even analysis of the understudied plant, if the number of failures exceeds 3 failures per year for the case of maximum demand charge of RM56.80, it is more economical to install a generator set as redundancy. The study will be useful for the co-generator operators to evaluate the feasibility of redundancy systems.

  10. Application and design of an economizer for waste heat recovery in a cogeneration plant

    Directory of Open Access Journals (Sweden)

    Martić Igor I.

    2016-01-01

    Full Text Available Energy increase cost has required its more effective use. However, many industrial heating processes generate waste energy. Use of waste-heat recovery systems decreases energy consumption. This paper presents case study of waste heat recovering of the exhaust flue gas in a 1415 kWe cogeneration plant. This waste heat can be recovered by installing an economizer to heat the condensed and fresh water in thermal degasification unit and reduce steam use for maintaining the temperature of 105˚C for oxygen removal. Design methodology of economizer is presented.

  11. Technical feasibility and economics of retrofitting an existing nuclear power plant to cogeneration for hot water district heating

    International Nuclear Information System (INIS)

    Kolb, J.O.; Bauman, H.F.; Jones, P.D.

    1984-04-01

    This report gives the results of a study of the hypothetical conversion of the Prairie Island Nuclear Plant of the Northern States Power Company to cogeneration operation to supply a future hot water district heating system load in the Twin Cities of Minneapolis-St. Paul. The conceptual design of the nuclear turbine retrofitted for cogeneration and of a hot water transmission system has been performed, and the capital investment and annual owning and operating costs have been estimated for thermal energy capacities of 600 and 1200 MW(t). Unit costs of thermal energy (in mid-1982 dollars/million Btu) have been estimated for cogenerated hot water at the plant gate and also for the most economic transmission system from Prairie Island to the Twin Cities. The economic results from the analysis of the Prairie Island plant and transmission route have been generalized for other transmission distances in other locations

  12. Technical feasibility and economics of retrofitting an existing nuclear power plant to cogeneration for hot water district heating

    Energy Technology Data Exchange (ETDEWEB)

    Kolb, J.O.; Bauman, H.F.; Jones, P.D.

    1984-04-01

    This report gives the results of a study of the hypothetical conversion of the Prairie Island Nuclear Plant of the Northern States Power Company to cogeneration operation to supply a future hot water district heating system load in the Twin Cities of Minneapolis-St. Paul. The conceptual design of the nuclear turbine retrofitted for cogeneration and of a hot water transmission system has been performed, and the capital investment and annual owning and operating costs have been estimated for thermal energy capacities of 600 and 1200 MW(t). Unit costs of thermal energy (in mid-1982 dollars/million Btu) have been estimated for cogenerated hot water at the plant gate and also for the most economic transmission system from Prairie Island to the Twin Cities. The economic results from the analysis of the Prairie Island plant and transmission route have been generalized for other transmission distances in other locations.

  13. Thermodynamic evaluation for cogeneration plant of a shopping center; Avaliacao termodinamica de uma planta cogerativa de um shopping center

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Gean C.S.; Torres, Ednildo A. [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil); Campos, Michel F. [PETROBRAS S.A., Salvador, BA (Brazil)

    2004-07-01

    Recent instability in the Brazilian electrical energy supply, together with the re-structuring of the power sector and government initiatives to increase natural gas participation in the system have led to discussion over the possibility of implementing cogeneration plants that utilize natural gas as an energy source in power generating for use in cooling and heating systems. Given this context, the use of cogeneration plants is an alternative for service sector companies (such as retail centers, universities, schools, and hospitals) that would like to implement with the goal of producing electricity and cooling for indoor environmental climate control. In this study, an energetic analysis (based on the first law of thermodynamics) and an exergetic analysis (based on the second law) were performed on two cogeneration plants. (author)

  14. Next Generation Nuclear Plant Project Evaluation of Siting a HTGR Co-generation Plant on an Operating Commercial Nuclear Power Plant Site

    International Nuclear Information System (INIS)

    Demick, L.E.

    2011-01-01

    This paper summarizes an evaluation by the Idaho National Laboratory (INL) Next Generation Nuclear Plant (NGNP) Project of siting a High Temperature Gas-cooled Reactor (HTGR) plant on an existing nuclear plant site that is located in an area of significant industrial activity. This is a co-generation application in which the HTGR Plant will be supplying steam and electricity to one or more of the nearby industrial plants.

  15. Next Generation Nuclear Plant Project Evaluation of Siting a HTGR Co-generation Plant on an Operating Commercial Nuclear Power Plant Site

    Energy Technology Data Exchange (ETDEWEB)

    L.E. Demick

    2011-10-01

    This paper summarizes an evaluation by the Idaho National Laboratory (INL) Next Generation Nuclear Plant (NGNP) Project of siting a High Temperature Gas-cooled Reactor (HTGR) plant on an existing nuclear plant site that is located in an area of significant industrial activity. This is a co-generation application in which the HTGR Plant will be supplying steam and electricity to one or more of the nearby industrial plants.

  16. Modelling the adoption of industrial cogeneration in Japan using manufacturing plant survey data

    International Nuclear Information System (INIS)

    Bonilla, David; Akisawa, Atsushi; Kashiwagi, Takao

    2003-01-01

    Electric power deregulation in Japan opens opportunity for further penetration of on-site generation (cogeneration) otherwise known as distributed generation. In the paper the authors present a survey on Japanese industrial plants to fill existing gaps for the assessment of modern cogeneration (combined heat and power, CHP). The objective of the paper is to empirically examine CHP systems based on cross-sectional binary models; second to review diffusion trends of CHP by system vintage during the 1980-2000 period in the manufacturing sector. The econometric results point that the probabilities of embracing this technology increase, in declining importance, with on-site power consumption, and steam demand, operational hours as well as with payback period, purchased power. For example the survey shows that the CHP is used for the purpose of exporting power rather than meeting the plant's own consumption. Some of our results are in line with those of Dismukes and Kleit (Resource Energy Econ. 21 (1999) 153) as well with Rose and Macdonald (Energy J. 12(12) (1991) 47). We also find that a unit increase in satisfaction with CHP will lead to a 54% in CHP capacity. We find significant evidence on the cost effectiveness of CHP under conservative assumptions. Regarding the influence of satisfaction and performance indicators for the several plants, the survey threw some unexpected evidence on the nature of CHP

  17. Modelling and simulation of cogeneration nuclear power plant for seawater desalination

    International Nuclear Information System (INIS)

    Asiedu-Boateng, P.

    2010-01-01

    Nuclear desalination of seawater remains a very viable option to solving the perennial fresh water shortage problem along the coast of Ghana especially as Ghana prepares to install the first nuclear power plant. There is, therefore, the need for research to be conducted into nuclear seawater desalination technology as part of the nuclear power programme of Ghana so as to develop the needed human resources in Ghana. In this research, cycle analysis of the cogeneration nuclear power plant was conducted to determine its efficiency and desalination steam requirements. An analytical model of the thermal vapour compression (TVC) desalination process was also developed to investigate the effect of designed and operating parameters controlling the cost of producing fresh water from TVC process. Steady state mass and energy balances as well as empirical correlations derived from experiments were used to model the TVC, which was coupled to a Nuclear Heating Reactor (NHR - 200) to supply the needed steam for the desalination. The model was developed into a computer code, NUCDES, written in FORTRAN95 programming language. The results show that the thermal performance ratio (P.R) of the TVC desalination process improves with efficiency of the cogeneration nuclear power plant but decreases with increasing steam consumption rates. The model can be used to conduct a parametric study of the single effect thermal vapour compression desalination process and also the potential to enhance Research and Development in nuclear desalination technology as well as develop future human resources in the field of nuclear desalination. (au)

  18. Identification of optimum steam extraction scheme for desalination plant on cogeneration purpose PWR type NPP

    International Nuclear Information System (INIS)

    Dedy Priambodo; Erlan Dewita; Sudi Ariyanto

    2011-01-01

    According to International Desalination Association 2009, there are 14,400 desalination installations in the world which produced 59.9 million m 3 per day and it was estimated to be increase continuously about 12,3% per year. Generally, fossil fuel has used as heat source which its combustion process will emit of CO 2 gas and another greenhouse gases. Increasing of fossil fuel utilization as energy process source, in : large scale desalination plant is not sustainable long-term option in term of environmental impact viewpoint. Nuclear Power Plant (NPP) is one of energy source which can produce large scale energy and it is also potential for cogeneration purposes which it produce electricity, as well as nuclear heat is also used for heat process, such as : desalination. Among all NPP type, PWR is the most utilized. In the heat utilization of PWR type NPP for desalination is needed a steam source selection of NPP secondary cycle. The exact selection of steam extraction point will be resulting an optimum cogeneration system to fulfil heat requirement for desalination by reduction of electricity as minimal as possible. Basically, there are 4 scheme scenario which are based on 2 steam extraction points, namely cross pipe and extraction line. Optimization is conducted by using Cycle Tempo Programme. Result of this study showed that third scheme of crossover pipe of steam extraction point is the best scheme with 1,039.1 MWe of power, 34.5 MWe of internal electricity needs and 149 MWe of power loss by cogeneration system and 1,004.6 MWe of transmission power. (author)

  19. Cogeneration and local authorities; Cogeneration et collectivites territoriales

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This conference is composed of 15 communications concerning cogeneration systems and applications in local communities. The main themes are: the regulation context and administrative procedures for cogeneration projects in France; legal aspects, risk covering, financing and sellback conditions for cogeneration systems; examples of cogeneration and tri-generation (with refrigeration energy) in different cities, airport, hospitals, campus, combined with the upgrading of district heating systems or municipal waste incineration plants. Impacts on energy savings and air pollution are also discussed

  20. Comparative exergoeconomic analysis of prime movers of cogeneration plants; Avaliacao exergoeconomica comparativa de acionadores primarios de plantas de cogeracao

    Energy Technology Data Exchange (ETDEWEB)

    Donatelli, Joao L.M. [Espirito Santo Univ., Vitoria, ES (Brazil). Dept. de Engenharia Mecanica]. E-mail: donatelli@lttc.com.ufrj.br; Vieira, Leonardo S.R. [Centro de Pesquisas de Energia Eletrica, Rio de Janeiro, RJ (Brazil). Area de Conhecimento de Materiais e Mecanica]. E-mail: lsrv@cepel.br; Cruz, Manuel E.C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica]. E-mail: manuel@serv.com.ufrj.br

    2000-07-01

    In this paper we apply exergoeconomic principles to perform a comparative analysis of the use of internal combustion engines or gas turbines as prime movers of cogeneration plants. A preliminary comparison of these movers can be obtained by analysing them individually, considering the complete utilization of the generated products rated on a common exergetic basis. However, when these movers are integrated in a cogeneration plant, it is necessary to perform a global system analysis, which will consider the coupling between generation capacity and demand, under the design conditions. The design of a cogeneration plant should, ideally, consider all the aspects that affect its performance. In this paper we take into account several aspects which are not normally collectively considered in similar analyses encountered in the literature. Specifically, the comparative procedure considers the electrical tariff on an hourly basis, the electrical and thermal load profiles, the influence of the environmental conditions on the performance of the prime movers, sizing and operation mode options to meet plant loads, part-load efficiency, different criteria for cost partitioning, and, finally, the effect of size on plant cost. Once the operating conditions of the cogeneration plant are defined, the procedure attributes costs to all the fluxes, allowing for the identification of the ranges of capacity where each mover is economically advantageous. We apply the procedure to the energetic supply analysis of a typical process of Brazilian shopping centers. (author)

  1. Integration of Biorefineries and Nuclear Cogeneration Power Plants - A Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Greene, Sherrell R [ORNL; Flanagan, George F [ORNL; Borole, Abhijeet P [ORNL

    2009-03-01

    Biomass-based ethanol and nuclear power are two viable elements in the path to U.S. energy independence. Numerous studies suggest nuclear power could provide a practical carbon-free heat source alternative for the production of biomass-based ethanol. In order for this coupling to occur, it is necessary to examine the interfacial requirements of both nuclear power plants and bioethanol refineries. This report describes the proposed characteristics of a small cogeneration nuclear power plant, a biochemical process-based cellulosic bioethanol refinery, and a thermochemical process-based cellulosic biorefinery. Systemic and interfacial issues relating to the co-location of either type of bioethanol facility with a nuclear power plant are presented and discussed. Results indicate future co-location efforts will require a new optimized energy strategy focused on overcoming the interfacial challenges identified in the report.

  2. Performance investigation of a cogeneration plant with the efficient and compact heat recovery system

    KAUST Repository

    Myat, Aung

    2011-10-03

    This paper presents the performance investigation of a cogeneration plant equipped with an efficient waste heat recovery system. The proposed cogeneration system produces four types of useful energy namely: (i) electricity, (ii) steam, (iii) cooling and (iv) dehumidification. The proposed plant comprises a Capstone C30 micro-turbine which generates 24 kW of electricity, a compact and efficient waste heat recovery system and a host of waste heat activated devices namely (i) a steam generator, (ii) an absorption chiller, (iii) an adsorption chiller and (iv) a multi-bed desiccant dehumidifier. The numerical analysis for the host of waste heat recovery system and thermally activated devices using FORTRAN power station linked to powerful IMSL library is performed to investigate the performance of the overall system. A set of experiments, both part load and full load, of micro-turbine is conducted to examine the electricity generation and the exhaust gas temperature. It is observed that energy utilization factor (EUF) could achieve as high as 70% while Fuel Energy Saving Ratio (FESR) is found to be 28%.

  3. Entropy generation minimization: A practical approach for performance evaluation of temperature cascaded co-generation plants

    KAUST Repository

    Myat, Aung

    2012-10-01

    We present a practical tool that employs entropy generation minimization (EGM) approach for an in-depth performance evaluation of a co-generation plant with a temperature-cascaded concept. Co-generation plant produces useful effect production sequentially, i.e., (i) electricity from the micro-turbines, (ii) low pressure steam at 250 °C or about 8-10 bars, (iii) cooling capacity of 4 refrigeration tones (Rtons) and (iv) dehumidification of outdoor air for air conditioned space. The main objective is to configure the most efficient configuration of producing power and heat. We employed entropy generation minimization (EGM) which reflects to minimize the dissipative losses and maximize the cycle efficiency of the individual thermally activated systems. The minimization of dissipative losses or EGM is performed in two steps namely, (i) adjusting heat source temperatures for the heat-fired cycles and (ii) the use of Genetic Algorithm (GA), to seek out the sensitivity of heat transfer areas, flow rates of working fluids, inlet temperatures of heat sources and coolant, etc., over the anticipated range of operation to achieve maximum efficiency. With EGM equipped with GA, we verified that the local minimization of entropy generation individually at each of the heat-activated processes would lead to the maximum efficiency of the system. © 2012.

  4. Equipment sizing in a coal-fired municipal heating plant modernisation project with support for renewable energy and cogeneration technologies

    International Nuclear Information System (INIS)

    Kalina, Jacek

    2014-01-01

    Highlights: • Sizing of biomass fired cogeneration block is performed for existing heating plant. • Mathematical model for cogeneration block optimisation is presented. • Impact of financial support mechanisms on optimal solution is discussed. • Influence of short term variations of prices and support intensity is presented. • Different design parameters are suggested by economic and technical quality indices. - Abstract: The paper presents results of design parameters optimisation of a wood chips fired steam boiler based heat and power block in a sample project of coal fired municipal heating plant modernisation. The project assumes the conversion of the heating plant into a dual fuel heat and power plant. The problem that is presented is selection of cogeneration block structure and thermodynamic parameters taking into account financial support mechanisms for cogeneration and renewable energy technologies. There are examined energy conversion and financial performances of the project. The results show that without the financial support the project is not profitable although it generates savings of primary energy of fossil fuels. If an administrative incentives are applied the optimal technical solution is different than suggested by energy conversion efficiency or fossil fuel savings. Financial calculations were performed for Polish marked conditions in the years 2011 and 2014 showing the impact of relatively short term variations of prices and support intensity on optimal plant design parameters

  5. Production of Bioethanol from Agricultural Wastes Using Residual Thermal Energy of a Cogeneration Plant in the Distillation Phase

    Directory of Open Access Journals (Sweden)

    Raffaela Cutzu

    2017-05-01

    Full Text Available Alcoholic fermentations were performed, adapting the technology to exploit the residual thermal energy (hot water at 83–85 °C of a cogeneration plant and to valorize agricultural wastes. Substrates were apple, kiwifruit, and peaches wastes; and corn threshing residue (CTR. Saccharomyces bayanus was chosen as starter yeast. The fruits, fresh or blanched, were mashed; CTR was gelatinized and liquefied by adding Liquozyme® SC DS (Novozymes, Dittingen, Switzerland; saccharification simultaneous to fermentation was carried out using the enzyme Spirizyme® Ultra (Novozymes, Dittingen, Switzerland. Lab-scale static fermentations were carried out at 28 °C and 35 °C, using raw fruits, blanched fruits and CTR, monitoring the ethanol production. The highest ethanol production was reached with CTR (10.22% (v/v and among fruits with apple (8.71% (v/v. Distillations at low temperatures and under vacuum, to exploit warm water from a cogeneration plant, were tested. Vacuum simple batch distillation by rotary evaporation at lab scale at 80 °C (heating bath and 200 mbar or 400 mbar allowed to recover 93.35% (v/v and 89.59% (v/v of ethanol, respectively. These results support a fermentation process coupled to a cogeneration plant, fed with apple wastes and with CTR when apple wastes are not available, where hot water from cogeneration plant is used in blanching and distillation phases. The scale up in a pilot plant was also carried out.

  6. North Plant co-generation project for South Davis County Sewer Improvement District

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, L.S. [Aqua Environmental Services, Inc., Bountiful, UT (United States)

    1993-12-31

    In the summer of 1988, the South Davis County Sewer Improvement District (SDCSID) learned of a grant/loan program being administered by the Utah State Department of Energy(DOE) for projects that demonstrate new and innovative ways of conserving energy or utilizing renewable energy sources. The SDCSID applied for and received from the DOE both a grant and a no-interest loan to finance half of the cost of a co-generation project at the North Wastewater Treatment Plant. This co-generation project utilizes methane gas, a by-product of the anaerobic digestion process, to generate both electricity and heat that is used at the plant. The SDCSID calculated that at the current anaerobic gas production rate, a 140 KW engine generator could be run almost 24 hours a day. Approximately 75% of the current electrical needs at the North Plant are supplied by the 140 KW engine generator. Also, all of the heat necessary to raise the temperature of the incoming sludge to 95{degrees}F, and to heat four large buildings is supplied from the heat recovery system of the engine. The system utilizes an induction type generator to supply electricity, which is somewhat simpler to design and less expensive to install than a synchronous type system. An induction system utilizes the Electrical Utility`s incoming power to excite the generator to correct the phase so that is can be used by the loads in the plant. In addition, the SDCSID installed a second identical engine generator as a back-up and to peak shave. Plant effluent is used to cool the engines instead of air-cooling through radiators.

  7. Cogeneration in the sugarcane industry - medium plants; A cogeracao no setor sucroalcooleiro - usinas de medio porte

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, Maria Cristina [Companhia Energetica de Sao Paulo (CESP), SP (Brazil)]. E-mail: epg@cesp.com.br; Ramos, Dorel Soares [Sao Paulo Univ., SP (Brazil). Escola Politecnica]. E-mail: dorelram@pea.usp.br

    2000-07-01

    This work aims at to analyze the re powering of medium sized sugar and alcohol plants located in the Southeast area of Sao Paulo State. Through a study case considering a standard unit that processes ten thousand tons of sugarcane per day, simulations were made using a mathematical model denominated Modelo de Despacho Hidrotermico, which supports the decision process for the expansion of electric energy offers. As a result of these simulations, it was possible to get the standard dispatch profile for such cogeneration plants, expressed by a medium capacity factor of 89%, demonstrating, therefore, the significant participation that these units can have in the energy context. Furthermore, a brief discussion about the energy price and capital return time is introduced, emphasizing the attractiveness of this kind of enterprise. (author)

  8. Thermodynamic and economic evaluation of a solar aided sugarcane bagasse cogeneration power plant

    International Nuclear Information System (INIS)

    Burin, Eduardo Konrad; Vogel, Tobias; Multhaupt, Sven; Thelen, Andre; Oeljeklaus, Gerd; Görner, Klaus; Bazzo, Edson

    2016-01-01

    This work evaluated the integration of Concentrated Solar Power (CSP) with a sugarcane bagasse cogeneration plant located in Campo Grande (Brazil). The plant is equipped with two 170 t/h capacity steam generators that provide steam at 67 bar/525 °C. Superheated steam is expanded in a backpressure and in a condensing-extraction turbine. The evaluated hybridization layouts were: (layout 1) solar feedwater pre-heating; (layout 2) saturated steam generation with solar energy and post superheating in biomass steam generators and (layout 3) superheated steam generation in parallel with biomass boilers. Linear Fresnel and parabolic trough were implemented in layouts 1 and 2, while solar tower in layout 3. The exportation of electricity to the grid was increased between 1.3% (layout 1/linear Fresnel) and 19.8% (layout 3) in comparison with base case. The levelized cost of additional electricity was accounted between 220 US$/MWh (layout 3) and 628 US$/MWh (layout 1/linear Fresnel). The key factor related to layout 3 was the improvement of solar field capacity factor due to the solar-only operation of this approach. These aspects demonstrate that the combination of solar and bagasse resources might be the key to turn CSP economically feasible in Brazil. - Highlights: • The integration of CSP and a sugarcane bagasse cogeneration plant was here evaluated. • Additional hours of operation during off-season were achieved due to hybridization. • The part load performance of plant was predicted as solar thermal load was increased. • The electricity exportation to the grid could be increased between 1.3 and 19.8%. • The LCOE of additional electricity produced was ranged between 220 and 628 US$/MWh.

  9. Reactor type choice and characteristics for a small nuclear heat and electricity co-generation plant

    International Nuclear Information System (INIS)

    Liu Kukui; Li Manchang; Tang Chuanbao

    1997-01-01

    In China heat supply consumes more than 70 percent of the primary energy resource, which makes for heavy traffic and transportation and produces a lot of polluting materials such as NO x , SO x and CO 2 because of use of the fossil fuel. The utilization of nuclear power into the heat and electricity co-generation plant contributes to the global environmental protection. The basic concept of the nuclear system is an integral type reactor with three circuits. The primary circuit equipment is enclosed in and linked up directly with reactor vessel. The third circuit produces steam for heat and electricity supply. This paper presents basic requirements, reactor type choice, design characteristics, economy for a nuclear co-generation plant and its future application. The choice of the main parameters and the main technological process is the key problem of the nuclear plant design. To make this paper clearer, take for example a double-reactor plant of 450 x 2MW thermal power. There are two sorts of main technological processes. One is a water-water-steam process. Another is water-steam-steam process. Compared the two sorts, the design which adopted the water-water-steam technological process has much more advantage. The system is simplified, the operation reliability is increased, the primary pressure reduces a lot, the temperature difference between the secondary and the third circuits becomes larger, so the size and capacity of the main components will be smaller, the scale and the cost of the building will be cut down. In this design, the secondary circuit pressure is the highest among that of the three circuits. So the primary circuit radioactivity can not leak into the third circuit in case of accidents. (author)

  10. Industrial cogeneration optimization program

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    The purpose of this program was to identify up to 10 good near-term opportunities for cogeneration in 5 major energy-consuming industries which produce food, textiles, paper, chemicals, and refined petroleum; select, characterize, and optimize cogeneration systems for these identified opportunities to achieve maximum energy savings for minimum investment using currently available components of cogenerating systems; and to identify technical, institutional, and regulatory obstacles hindering the use of industrial cogeneration systems. The analysis methods used and results obtained are described. Plants with fuel demands from 100,000 Btu/h to 3 x 10/sup 6/ Btu/h were considered. It was concluded that the major impediments to industrial cogeneration are financial, e.g., high capital investment and high charges by electric utilities during short-term cogeneration facility outages. In the plants considered an average energy savings from cogeneration of 15 to 18% compared to separate generation of process steam and electric power was calculated. On a national basis for the 5 industries considered, this extrapolates to saving 1.3 to 1.6 quads per yr or between 630,000 to 750,000 bbl/d of oil. Properly applied, federal activity can do much to realize a substantial fraction of this potential by lowering the barriers to cogeneration and by stimulating wider implementation of this technology. (LCL)

  11. Exergetic analysis of cogeneration plants through integration of internal combustion engine and process simulators

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Leonardo de Oliveira [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil)], E-mail: leonardo.carvalho@petrobras.com.br; Leiroz, Albino Kalab; Cruz, Manuel Ernani [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Mecanica], Emails: leiroz@mecanica.ufrj.br, manuel@mecanica.ufrj.br

    2010-07-01

    Internal combustion engines (ICEs) have been used in industry and power generation much before they were massively employed for transportation. Their high reliability, excellent power-to-weight ratio, and thermal efficiency have made them a competitive choice as main energy converters in small to medium sized power plants. Process simulators can model ICE powered energy plants with limited depth, due to the highly simplified ICE models used. Usually a better understanding of the global effects of different engine parameters is desirable, since the combustion process within the ICE is typically the main cause of exergy destruction in systems which utilize them. Dedicated commercial ICE simulators have reached such a degree of maturity, that they can adequately model a wide spectrum of phenomena that occur in ICEs. However, ICE simulators are unable to incorporate the remaining of power plant equipment and processes in their models. This paper presents and exploits the integration of an internal combustion engine simulator with a process simulator, so as to evaluate the construction of a fully coupled simulation platform to analyze the performance of ICE-based power plants. A simulation model of an actual cogeneration plant is used as a vehicle for application of the proposed computational methodology. The results show that by manipulating the engine mapping parameters, the overall efficiency of the plant can be improved. (author)

  12. Experiences from the Swedish programme - heavy water and natural uranium in the Aagesta cogeneration plant

    International Nuclear Information System (INIS)

    Oestman, Alvar

    2002-11-01

    A short review of the Swedish programme for nuclear power in the 50's and the 60's is given, and in particular a description of the operating experiences of the Aagesta nuclear cogeneration plant, producing district heating for the south Stockholm area (12 MW el and 68 MW heat ). The original Swedish nuclear programme was built on heavy water and natural uranium and had the objective to construct small nuclear plants in the vicinity of some 10 large cities in south and middle Sweden. Aagesta was the only full-scale plant to be built according to this programme, as Sweden adopted the light-water reactor policy and eventually constructed 12 large reactors at four sites. The report is based on the experiences of the author from his work at the Aagesta plant in the sixties. In an appendix, the experiences from Vattenfall (the Swedish electric utility which took over the operating responsibility for the Aagesta plant), of the plant operation is reviewed

  13. An integral reactor design concept for a nuclear co-generation plant

    International Nuclear Information System (INIS)

    Lee, D.J.; Kim, J.I.; Kim, K.K.; Chang, M.H.; Moon, K.S.

    1997-01-01

    An integral reactor concept for nuclear cogeneration plant is being developed at KAERI as an attempt to expand the peaceful utilization of well established commercial nuclear technology, and related industrial infrastructure such as desalination technology in Korea. Advanced technologies such as intrinsic and passive safety features are implemented in establishing the design concepts to enhance the safety and performance. Research and development including laboratory-scale tests are concurrently underway to evaluate the characteristics of various passive safety concepts and provide the proper technical data for the conceptual design. This paper describes the preliminary safety and design concepts of the advanced integral reactor. Salient features of the design are hexagonal core geometry, once-through helical steam generator, self-pressurizer, and seismic resistant fine control CEDMS, passive residual heat removal system, steam injector driven passive containment cooling system. (author)

  14. EARLY ENTRANCE CO-PRODUCTION PLANT - DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    International Nuclear Information System (INIS)

    Unknown

    2001-01-01

    Waste Processors Management Inc. (WMPI), along with its subcontractors entered into a cooperative agreement with the USDOE to assess the techno-economic viability of building an Early Entrance Co-Production Plant (EECP) in the US that produces ultra clean Fischer-Tropsch transportation fuels with either power or steam as the major co-product. The EECP will emphasize on reclaiming and gasifying low-cost coal waste and/or its mixture as the primary feedstocks. The project consists of three phases. Phase I objectives include conceptual development, technical assessment, feasibility design and economic evaluation of a Greenfield commercial co-production plant and a site specific demonstration EECP to be located adjacent to the existing WMPI Gilberton Power Station. There is very little foreseen design differences between the Greenfield commercial coproduction plant versus the EECP plant other than: The greenfield commercial plant will be a stand alone FT/power co-production plant, potentially larger in capacity to take full advantage of economy of scale, and to be located in either western Pennsylvania, West Virginia or Ohio, using bituminous coal waste (gob) and Pennsylvania No.8 coal or other comparable coal as the feedstock; The EECP plant, on the other hand, will be a nominal 5000 bpd plant, fully integrated into the Gilbertson Power Company's Cogeneration Plant to take advantage of the existing infrastructure to reduce cost and minimize project risk. The Gilberton EECP plant will be designed to use eastern Pennsylvania anthracite coal waste and/or its mixture as feedstock

  15. Optimal design of modular cogeneration plants for hospital facilities and robustness evaluation of the results

    International Nuclear Information System (INIS)

    Gimelli, A.; Muccillo, M.; Sannino, R.

    2017-01-01

    Highlights: • A specific methodology has been set up based on genetic optimization algorithm. • Results highlight a tradeoff between primary energy savings (TPES) and simple payback (SPB). • Optimized plant configurations show TPES exceeding 18% and SPB of approximately three years. • The study aims to identify the most stable plant solutions through the robust design optimization. • The research shows how a deterministic definition of the decision variables could lead to an overestimation of the results. - Abstract: The widespread adoption of combined heat and power generation is widely recognized as a strategic goal to achieve significant primary energy savings and lower carbon dioxide emissions. In this context, the purpose of this research is to evaluate the potential of cogeneration based on reciprocating gas engines for some Italian hospital buildings. Comparative analyses have been conducted based on the load profiles of two specific hospital facilities and through the study of the cogeneration system-user interaction. To this end, a specific methodology has been set up by coupling a specifically developed calculation algorithm to a genetic optimization algorithm, and a multi-objective approach has been adopted. The results from the optimization problem highlight a clear trade-off between total primary energy savings (TPES) and simple payback period (SPB). Optimized plant configurations and management strategies show TPES exceeding 18% for the reference hospital facilities and multi–gas engine solutions along with a minimum SPB of approximately three years, thereby justifying the European regulation promoting cogeneration. However, designing a CHP plant for a specific energetic, legislative or market scenario does not guarantee good performance when these scenarios change. For this reason, the proposed methodology has been enhanced in order to focus on some innovative aspects. In particular, this study proposes an uncommon and effective approach

  16. EARLY ENTRANCE CO-PRODUCTION PLANT - DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    International Nuclear Information System (INIS)

    Unknown

    2001-01-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors Texaco Power and Gasification, SASOL Technology Ltd., and Nexant Inc. entered into a Cooperative Agreement DE-FC26-00NT40693 with the US Department of Energy (DOE), National Energy Technology Laboratory (NETL) to assess the techno-economic viability of building an Early Entrance Co-Production Plant (EECP) in the US to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co-product. The EECP designs emphasize on recovery and gasification of low-cost coal waste (culm) from coal clean operations and will assess blends of the culm and coal or petroleum coke as feedstocks. The project is being carried out in three phases. Phase I involves definition of concept and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase II consists of an experimental testing program designed to validate the coal waste mixture gasification performance. Phase III involves updating the original EECP design, based on results from Phase II, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 BPD coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania

  17. Performance assessment of non-self-regulating controllers in a cogeneration power plant

    International Nuclear Information System (INIS)

    Howard, Rachelle; Cooper, Douglas J.

    2009-01-01

    This work details a novel method for assessing the performance of a PI (proportional-integral) feedback controller when the process displays non-self-regulating dynamic behavior. By applying an intuitive process control-based pattern recognition method to the autocorrelation function of the process measurement signal, the controller's disturbance rejection performance can automatically be categorized. Stochastic data collected over days or weeks is analyzed to compute an index descriptive of current controller performance. If the control response has drifted from a user-defined target value, the analysis further provides a guide for tuning adjustments to restore desired performance. Significant aspects of this approach are that no plant disruption or process knowledge is required for evaluation. Classic examples of non-self-regulating behavior include certain liquid level control loops and pressure control loops which are prevalent in cogeneration power plants. In this work, we detail how the performance assessment method was used to improve performance of such controllers in the University of Connecticut's power plant.

  18. Cogeneration in Australia. Situation and prospects

    International Nuclear Information System (INIS)

    1997-01-01

    This Research Paper is mainly concerned with the status and prospects for cogeneration in Australia. An introductory chapter reviews the fundamentals of cogeneration, covering both technical and institutional aspects. A range of technologies are employed in cogeneration: these technologies and their efficiency and environmental impact effects are discussed in Chapter 2. The economics of cogeneration are a major factor in the profitability of current and potential plants. Potential factors affecting cogeneration economics are discussed .The status of cogeneration in Australia is reviewed for each State and Territory, and includes a number of case studies of existing plants. Government (federal, state, territory) policies that have a significant impact on the attractiveness of cogeneration are reviewed. Finally, the future prospects for cogeneration in Australia, drawing on the preceding chapters and a review of estimated potentials for cogeneration in Australia are presented

  19. Benefits of compressor inlet air cooling for gas turbine cogeneration plants

    Energy Technology Data Exchange (ETDEWEB)

    De Lucia, M.; Lanfranchi, C. [Univ. di Firenze (Italy). Dept. di Energetica; Boggio, V. [CRIT S.r.l., Prato (Italy)

    1996-07-01

    Compressor inlet air cooling is an effective method for enhancing the performance of gas turbine plants. This paper presents a comparative analysis of different solutions for cooling the compressor inlet air for the LM6000 gas turbine in a cogeneration plant operated in base load. Absorption and evaporative cooling systems are considered and their performance and economic benefits compared for the dry low-NO{sub x} LM6000 version. Reference is made to two sites in Northern and Southern Italy, whose climate data series for modeling the variations in ambient temperature during the single day were used to account for the effects of climate in the simulation. The results confirmed the advantages of inlet air cooling systems. In particular, evaporative cooling proved to be cost effective, though capable of supplying only moderate cooling, while absorption systems have a higher cost but are also more versatile and powerful in base-load operation. An integration of the two systems proved to be able to give both maximum performance enhancement and net economic benefit.

  20. Dynamic Simulation and Exergo-Economic Optimization of a Hybrid Solar–Geothermal Cogeneration Plant

    Directory of Open Access Journals (Sweden)

    Francesco Calise

    2015-04-01

    Full Text Available This paper presents a dynamic simulation model and a parametric analysis of a solar-geothermal hybrid cogeneration plant based on an Organic Rankine Cycle (ORC powered by a medium-enthalpy geothermal resource and a Parabolic Trough Collector solar field. The fluid temperature supplying heat to the ORC varies continuously as a function of the solar irradiation, affecting both the electrical and thermal energies produced by the system. Thus, a dynamic simulation was performed. The ORC model, developed in Engineering Equation Solver, is based on zero-dimensional energy and mass balances and includes specific algorithms to evaluate the off-design system performance. The overall simulation model of the solar-geothermal cogenerative plant was implemented in the TRNSYS environment. Here, the ORC model is imported, whereas the models of the other components of the system are developed on the basis of literature data. Results are analyzed on different time bases presenting energetic, economic and exergetic performance data. Finally, a rigorous optimization has been performed to determine the set of system design/control parameters minimizing simple payback period and exergy destruction rate. The system is profitable when a significant amount of the heat produced is consumed. The highest irreversibilities are due to the solar field and to the heat exchangers.

  1. Experimental results and thermodynamic analysis of a natural gas small scale cogeneration plant for power and refrigeration purposes

    International Nuclear Information System (INIS)

    Bazzo, Edson; Nacif de Carvalho, Alvaro; Matelli, José Alexandre

    2013-01-01

    In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24 °C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at −5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. -- Highlights: • A small scale cogeneration plant for power and refrigeration is proposed and analyzed. • The plant is based on a microturbine and a modified absorption chiller. • The plant is analysed based on 1st and 2nd laws of thermodynamics. • Experimental results are found for different power and refrigeration conditions. • The plant proved to be technically feasible

  2. A decision support assessment of cogeneration plant for a community energy system in Korea

    International Nuclear Information System (INIS)

    Chung, Mo; Park, Chuhwan; Lee, Sukgyu; Park, Hwa-Choon; Im, Yong-Hoon; Chang, Youngho

    2012-01-01

    We have undertaken a case study of a Combined Heat and Power (CHP) plant applied to a mixture of buildings comprising residential premises, offices, hospitals, stores, and schools in Korea. We proposed five Plans for grouping buildings in the complex and estimated the annual 8760-hourly demands for electricity, cooling, heating, and hot water. For each Plan, we built about ten Scenarios for system construction. Then, we simulated the operation of the system to find the fuel consumption, electricity purchase, and heat recovery. Applying the local rates to the amounts of fuel and electricity, we estimated the operating costs. Combining the operating cost with the initial cost associated with the purchase and construction of the system, we calculated the payback periods for the scenarios. We found that the payback period can be as short as two years for smartly grouped buildings with a generator capacity of around 50% of the peak electricity demand. A progressive electricity rate that applies only to residential premises currently plays a key role in the economic merits. We recommend extending a sound progressive system to other types of building in Korea to promote distributed power production and enhance energy saving practices in general. - Highlights: ►We case-studied cogeneration plants for a residential complex in Korea. ►We estimated the annual 8760-hourly demands for electricity, heating, and cooling. ► We simulated the operation of CHP and estimated the fuel and electricity costs. ► We found payback periods that were shorter than two years for well-planned systems. ► A progressive electricity tariff plays a key role in the economic merits.

  3. Review of the cost estimate and schedule for the 2240-MWt high-temperature gas-cooled reactor steam-cycle/cogeneration lead plant

    International Nuclear Information System (INIS)

    1983-09-01

    This report documents Bechtel's review of the cost estimate and schedule for the 2240 MWt High Temperature Gas-Cooled Reactor Steam Cycle/Cogeneration (HTGR-SC/C) Lead Plant. The overall objective of the review is to verify that the 1982 update of the cost estimate and schedule for the Lead Plant are reasonable and consistent with current power plant experience

  4. Nuclear Co-Generating Plants for Powering and Heating to Cleaning the Warsaw's Environment

    International Nuclear Information System (INIS)

    Baurski, J.

    2010-01-01

    In 2009 the Polish Government made a decision to introduce nuclear power to Poland. Two nuclear power plants (NPPs) will be constructed nearly at the same time - the first unit should start operation in 2020, and by 2030 there should be about 6000 MWe added to the national electrical grid. The Commissioner of the Government was nominated to introduce the Polish Nuclear Power Program (PNPP). One of the four vertically integrated - the biggest energy company (PGE - the Polish Energy Group with headquarters in Warsaw) was appointed to prepare investments. These activities are planned in four stages: I. up to 31.12.2010 - The PNPP will be prepared and the program must then be accepted by the Government. II. 2011 - 2013 - Sites will be determined, and the contract for construction of the first NPP will be closed. III. 2014 - 2015 - Technical specifications will be prepared and accepted according the law. IV. 2016 - 2020 - The first NPP in Poland will be constructed. At present, the Government is receiving proposals from some regions of Poland asking that they be chosen for the NPP. One of the obvious locations for the NPP is a 40-kilometer vicinity of Warsaw (1.8 mln inhabitants). The need for both electric power and heat is increasing because of the rapidly growing town. It gives the extremely valuable chance for a very high thermodynamic efficiency of 80% in co-generation instead of 33% (max 36% for EPR-1600) for NPP generated electric power only. The Warsaw heating system has a capacity of 3950 MWt and is the biggest among EU countries. It is the third biggest in the world. Two NPPs, each of 2 x 1000 MWe could be built on the Vistula River up and down the town. In 2005, UE calculated losses caused by gas emissions at 24 mld eur, and the span of human lives was six months shorter in western countries and 8 months shorter in Poland. Warsaw's atmosphere is very polluted also because there are four heat and power generating plants: three coal and one oil -fired. In these

  5. A study for the optimal operating conditions of the gas turbine based combined cycle cogeneration power plant

    International Nuclear Information System (INIS)

    Cho, Young Bin; Sohn, Jeong Lak; Ro, Sung Tack

    2004-01-01

    The purpose of this study is to show the existence of optimal operation conditions for minimum fuel consumption of the gas turbine based combined cycle cogeneration power plant. Optimal operational condition means the optimal distribution of the power generated by each gas turbine and the heat generated by each HRSG. Total fuel consumption is calculated by the sum of the fuels for gas turbines and supplementary boiler. Fuel consumption is calculated by numerical methods of energy equations which contain the power generated from gas and steam turbines, the heat generated by HRSG and the heat extracted from high pressure steam turbine

  6. A technical analysis for cogeneration systems with potential applications in twelve California industrial plants. [energy saving heat-electricity utility systems

    Science.gov (United States)

    Moretti, V. C.; Davis, H. S.; Slonski, M. L.

    1978-01-01

    In a study sponsored by the State of California Energy Resources Conservation and Development Commission, 12 industrial plants in five utility districts were surveyed to assess the potential applications of the cogeneration of heat and electricity in California industry. Thermodynamic calculations were made for each plant in determining the energy required to meet the existing electrical and steam demands. The present systems were then compared to conceptual cogeneration systems specified for each plant. Overall energy savings were determined for the cogeneration applications. Steam and gas turbine topping cycle systems were considered as well as bottoming cycle systems. Types of industries studied were: pulp and paper, timber, cement, petroleum refining, enhanced oil recovery, foods processing, steel and glass

  7. Feasibility of the operation CFE`s conventional power plants for industrial cogeneration; Factibilidad de operar las centrales termoelectricas convencionales de la CFE para cogeneracion industrial

    Energy Technology Data Exchange (ETDEWEB)

    Buendia Dominguez, Eduardo H.; Acosta Torres, Rosa Aracely [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    An analysis is made on how cogeneration could help to maximize the power plant performance since thanks to cogeneration this type of power plants could utilize a part of the waste energy to be supplied to other processes. Also mention is made of the utilization of computer programs to help the design and the realization of functioning tests of this type of power plants. An economic evaluation is presented on the feasibility of operating this type of power plants as cogeneration units and it is concluded that the operation of fossil power plants in the cogeneration mode is not affected by the site where the power plant is located [Espanol] Se analiza como la cogeneracion podria ayudar a maximizar el rendimiento de las centrales termoelectricas ya que gracias a la cogeneracion este tipo de centrales podrian utilizar una parte de la energia desechada para suministrarla a otros procesos. Tambien se menciona la utilizacion de programas de computo para auxiliar en el diseno o realizacion de pruebas de funcionamiento sobre este tipo de plantas. Se presenta una evaluacion economica sobre la factibilidad de operar este tipo de plantas como unidades de cogeneracion y se concluye en que la operacion de centrales termoelectricas en modo de cogeneracion no se ve afectado por el sitio donde se encuentra la central

  8. Optimising the operation of an LNG import terminal (Zeebrugge) with an integrated cogeneration plant; Optimisation de l'exploitation d'un terminal importateur de GNL (Zeebrugge) lie a une unite de cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    Van de Walle, F.; Gerard, A. [Distrigas (Belgium)

    2000-07-01

    Distrigas (Belgium) is operating an LNG Terminal in Zeebrugge since 1987, receiving some 3.25 million tonnes of LNG per year (60 shiploads of 125,000 m{sup 3} LNG). This LNG import covers some 30 % of the total natural gas consumption in Belgium. Re-gasification from 1987 until 1996 was solely with high-efficiency submerged combustion LNG vaporizers (open rack seawater vaporizers were not an option because in the winter period sea water temperature in Zeebrugge is too low: 4 deg. C and below). In 1995/1996 a 40 MW gas turbine cogeneration plant with a 72.5 MW heat recovery unit of novel design (including a direct-contact condensing cooling tower and a 50 deg. C/15 deg. C hot water circuit) was installed and integrated with the existing submerged combustion vaporizers. To realize this project, Distrigas signed a so-called 'cogeneration partnership' with its electric power supplier Electrabel. Start-up and initial operation were implemented without any interruption in the operation of the terminal. This poster presentation describes this cogeneration plant, and the optimisation since its initial operation in early 1997. (authors)

  9. Using in-house expertise in negotiating power sales contracts for industrial cogeneration plants

    International Nuclear Information System (INIS)

    Yott, R.A.

    1992-01-01

    Energy has always been a strategic component of Air Products and Chemicals production costs. In fact, Air Products is among the top consumers of electricity and natural gas in the U.S. Consequently, Air Products has developed a multifaceted Corporate Energy Department. The advent of PURPA in 1978 and the success enjoyed by Air Products in selling industrial gases over the fence to industrial customers as a integral part of their manufacturing system led Air Products into the industrial cogeneration business. This paper briefly summarizes Air Products entry into the industrial cogeneration market and the role that Air Products Energy Department has played in making this new business focus a success. It highlights how Air Products has been able to transfer its in-house expertise in purchasing power to the marketing, bidding, contract negotiation and avoided cost forecasting functions so critical in the successful development of industrial cogeneration opportunities. At Air Products we believe our long association with the utility industry first as a cost-conscious customer and more recently as an electric energy supplier has enhanced our competitive position. The same success story could be repeated at your company if you know what to look for and are not afraid to expand the horizons and responsibilities of your energy department

  10. Economic viability study of micro-cogeneration plants at residential scale; Estudo de viabilidade economica de plantas de micro-cogeracao em escala residencial

    Energy Technology Data Exchange (ETDEWEB)

    Dutra, Jose Carlos Charamba; Ramalho e Soares, Ravi [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Michalewicz, Jacek Stanislaw [Centro Federal de Educacao Tecnologica de Pernambuco (CEFET-PE), Recife, RN (Brazil)

    2008-07-01

    This paper presents the results of a technical and economical feasibility study for the use of micro cogeneration systems in residential scale, using natural gas as an energy source. It was considered two micro-cogeneration systems to meet demand of some types of fictitious establishment of commercial and residential plants, each with its advantages and disadvantages. The first system has as a main driving machine a micro turbine with a nominal capacity of 30 kw, the second one uses a gas motor-generator, with nominal capacity of 35 kw. (author)

  11. Micro-size cogeneration plants and virtual power plants. New energy landscapes; Mikro-KWK und virtuelle Kraftwerke. Neue Energielandschaften

    Energy Technology Data Exchange (ETDEWEB)

    Roon, Serafin von [Forschungsstelle fuer Energiewirtschaft e.V., Muenchen (Germany)

    2009-07-01

    Combined heat and power generation is an established technology. With micro-size cogeneration units, the technology is now available to private single or multiple dwellings and for decentral power supply of residential blocks. With the right political boundary conditions and integrated into virtual power stations, this is an option for enhanced use of renewable energy sources and for decentral, flexible and climate-friendly heat and power generation in buildings. Economic efficiency analyses by experts, high utilisation rates, innovative developments of the manufacturers and a positive public image are all in favour of a great future for micro-size cogeneration units. (orig.)

  12. High performance steam development. Final report, Phase No. 3: 1500{degree}F steam plant for industrial cogeneration prototype development tests

    Energy Technology Data Exchange (ETDEWEB)

    Duffy, T.; Schneider, P.

    1996-01-01

    As a key part of DOE`s and industry`s R&D efforts to improve the efficiency, cost, and emissions of power generation, a prototype High Performance Steam System (HPSS) has been designed, built, and demonstrated. The world`s highest temperature ASME Section I coded power plant successfully completed over 100 hours of development tests at 1500{degrees}F and 1500 psig on a 56,000 pound per hour steam generator, control valve and topping turbine at an output power of 5500 hp. This development advances the HPSS to 400{degrees}F higher steam temperature than the current best technology being installed around the world. Higher cycle temperatures produce higher conversion efficiencies and since steam is used to produce the large majority of the world`s power, the authors expect HPSS developments will have a major impact on electric power production and cogeneration in the twenty-first century. Coal fueled steam plants now produce the majority of the United States electric power. Cogeneration and reduced costs and availability of natural gas have now made gas turbines using Heat Recovery Steam Generators (HRSG`s) and combined cycles for cogeneration and power generation the lowest cost producer of electric power in the United States. These gas fueled combined cycles also have major benefits in reducing emissions while reducing the cost of electricity. Development of HPSS technology can significantly improve the efficiency of cogeneration, steam plants, and combined cycles. Figure 2 is a TS diagram that shows the HPSS has twice the energy available from each pound of steam when expanding from 1500{degrees}F and 1500 psia to 165 psia (150 psig, a common cogeneration process steam pressure). This report describes the prototype component and system design, and results of the 100-hour laboratory tests. The next phase of the program consists of building up the steam turbine into a generator set, and installing the power plant at an industrial site for extended operation.

  13. Performance investigation of a novel water–power cogeneration plant (WPCP) based on humidification dehumidification (HDH) method

    International Nuclear Information System (INIS)

    He, W.F.; Han, D.; Xu, L.N.; Yue, C.; Pu, W.H.

    2016-01-01

    Highlights: • A novel water–power cogeneration plant (WPCP) is proposed. • Energy analysis of the proposed WPCP is achieved. • Comparison of the WPCP performance at different pressures is fulfilled. • Performance correlation between the HDH desalination and ORC power subsystems is revealed. - Abstract: Humidification dehumidification (HDH) technology was well applied to produce freshwater in the desalination system. However, besides the demand of freshwater, power is also required simultaneously in most situations. In the paper, a novel water–power cogeneration plant (WPCP) based on the HDH desalination system coupled with the organic Rankine cycle (ORC) is proposed. Energy analysis for the proposed combined system at different appointed operation parameters is achieved, and the corresponding performance correlation between the HDH desalination and ORC power system are revealed. It is verified that the production of freshwater and electricity can be gained synchronously in the suggested novel platform, and the performance of the whole system is really sensitive to the operation parameters of the HDH desalination system. It is found that after the regulation of the operation pressure, p, and the seawater temperature at the outlet of the seawater heater, T sw,2 , for the HDH desalination from p = 0.1 MPa, T sw,2 = 353.15 K to p = 0.3 MPa, T sw,2 = 383.15 K, a maximum elevation, 25.46 kg h −1 for the freshwater production, 4.17 kW for the electricity and 2% for the extended gained output ratio (EGOR) is obtained. Furthermore, owing to the asynchronism between the specific production and the final energy utilization efficiency, the balance should be optimized among the demand of the freshwater and power and the efficiency of the novel WPCP.

  14. A biofuel-based cogeneration plant in a natural gas expansion system: An energetic and economic assessment

    International Nuclear Information System (INIS)

    Badami, Marco; Modica, Stefano; Portoraro, Armando

    2017-01-01

    Highlights: • A Natural Gas Turbo Expander system with a rapeseed oil fueled CHP is studied. • The experimental data of the plant are considered in the analyses. • The energetic index of performance shows the attractiveness of the plant. • Incentives and fuel price volatility effects on economic profitability are analysed. - Abstract: The paper deals with an analysis of the energetic and economic performance of a City Gas Station (CGS) plant, made up of a rapeseed oil cogenerator coupled to a turbo-expansion system for the reduction of natural gas pressure, which is currently in operation in Italy. Although this kind of systems concept is well known, the plant can be considered unusual because the heat needed to pre-heat the gas before its expansion is obtained from a renewable source. The aim of the paper is to analyse the energetic efficiency of the plant and its economic viability, which is affected to a great extent by subsidizing energy policies and by the volatility of vegetable oil prices. All the evaluations have been based on a real set of experimental data.

  15. Modeling and optimization of a novel solar chimney cogeneration power plant combined with solid oxide electrolysis/fuel cell

    International Nuclear Information System (INIS)

    Joneydi Shariatzadeh, O.; Refahi, A.H.; Abolhassani, S.S.; Rahmani, M.

    2015-01-01

    Highlights: • Proposed a solar chimney cogeneration power plant combined with solid oxide fuel cell. • Conducted single-objective economic optimization of cycle by genetic algorithm. • Stored surplus hydrogen in season solarium to supply electricity in winter by SOFC. - Abstract: Using solar chimney in desert areas like El Paso city in Texas, USA, with high intensity solar radiation is efficient and environmental friendly. However, one of the main challenges in terms of using solar chimneys is poor electricity generation at night. In this paper, a new power plant plan is proposed which simultaneously generates heat and electricity using a solar chimney with solid oxide fuel cells and solid oxide electrolysis cells. In one hand, the solar chimney generates electricity by sunlight and supplies a part of demand. Then, additional electricity is generated through the high temperature electrolysis which produces hydrogen that is stored in tanks and converted into electricity by solid oxide fuel cells. After designing and modeling the cycle components, the economic aspect of this power plant is considered numerically by means of genetic algorithm. The results indicate that, 0.28 kg/s hydrogen is produced at the peak of the radiation. With such a hydrogen production rate, this system supplies 79.26% and 37.04% of the demand in summer and winter respectively in a district of El Paso city.

  16. EARLY ENTRANCE CO-PRODUCTION PLANT--DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    Energy Technology Data Exchange (ETDEWEB)

    John W. Rich

    2001-03-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors Texaco Power and Gasification (now ChevronTexaco), SASOL Technology Ltd., and Nexant Inc. entered into a Cooperative Agreement with the USDOE, National Energy Technology Laboratory (NETL) to assess the techno-economic viability of building an Early Entrance Co-Production Plant (EECP) in the US to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co--product. The EECP design includes recovery and gasification of low-cost coal waste (culm) from physical coal cleaning operations and will assess blends of the culm with coal or petroleum coke. The project has three phases: Phase 1 is the concept definition and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase 2 is an experimental testing program designed to validate the coal waste mixture gasification performance. Phase 3 updates the original EECP design based on results from Phase 2, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 barrel per day (BPD) coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania. The current report is WMPI's third quarterly technical progress report. It covers the period performance from October 1, 2001 through December 31, 2001.

  17. Numerical simulation of a cogeneration plant with micro gas turbine using computational tool EES; Simulacao numerica de uma planta de cogeracao com microturbina a gas natural utilizando ferramenta computacional EES

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Guilherme L.B. de; Oliveira, Andrezza C.C.T.; Dutra, Jose C.C. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2008-07-01

    Today, the cogeneration of energy has been widely disseminated and presents itself as a very viable alternative for energy savings, reducing CO2 emissions by conducting reuse energy. This study aims to develop a software for simulation, analysis and optimization of a cogeneration system that uses a natural gas turbine as a primary source. The data contained in the software were similar to existing data in a micro-cogeneration plant installed at UFPE and the results showed up in the standard presented by actual plant. We conclude that the software serves as a tool to pre-analysis of the plant of choice for cogeneration equipment to be installed as: pumps, heat exchangers, chillers, cooling towers. (author)

  18. Analysis of gas turbine cogeneration plants in Italy; Indagine sulla funzionalita` degli impianti di cogenerazione conturbina a gas operanti in Italia

    Energy Technology Data Exchange (ETDEWEB)

    Romani, Rino; Vignati, Sigfrido [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Energia

    1997-10-01

    The purpose of this study is to improve, by random analysis, the current knowledge about functional and running data of gas turbine cogeneration plants in Italy. The analysis consider simple and combined cycle gas turbines plant with electric power less 30.000 k W per unit and involves a sample of 44 units according to a randomized model consisting of 112 gas turbines. The collected data show different plant selection criteria, energy performances, reliability and availability values as well as maintenance costs. These data support some general suggestions and recommendations for a better selection and utilization of these plants.

  19. Cogeneration Systems; Sistemas de Cogeneracion

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez M, Manuel F; Huante P, Liborio; Romo M, Cesar A [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2006-07-01

    The present article deals on relevant aspects on the subject of cogeneration within the Mexican territorial limits. In the first place it is presented the role of Mexico in terms of its cogeneration potential, the type of service that has obtained from this predominant modality of cogeneration for self-supplying, the most propitious sectors to develop it, its legislations on the matter, the projects made for the implementation of cogeneration plants, as well as the existing cogeneration schemes for its respective optimization proposals. Without leaving out the analysis on the different types of evaluation on the efficiency of cogeneration systems and the aspects to consider for the election of a generation cycle. [Spanish] El presente articulo trata sobre aspectos relevantes en materia de cogeneracion dentro de los limites territoriales de la nacion mexicana. Se muestra en primer lugar el papel de Mexico en terminos de su potencial de cogeneracion, el tipo de servicio que ha obtenido de esta predominantemente (modalidad de cogeneracion para autoabastecimiento), los sectores mas propicios para desarrollarla, sus legislaciones al respecto, los proyectos realizados para la implementacion de plantas de cogeneracion, asi como los esquemas de cogeneracion existentes con sus respectivas propuestas de optimizacion. Sin dejar de lado el analisis sobre los distintos tipos de evaluacion de la eficiencia de sistemas de cogeneracion y los aspectos a considerar para la eleccion de un ciclo de generacion.

  20. Conversion of coal-fired power plants to cogeneration and combined-cycle thermal and economic effectiveness

    CERN Document Server

    Bartnik, Ryszard

    2014-01-01

    This book covers methodology, calculation procedures and tools to support enterprise planning for adapting power stations to cogeneration and combined-cycle forms. It examines the optimum selection of the structure of heat exchangers in a 370 MW power block.

  1. Methodology for the optimal design of an integrated first and second generation ethanol production plant combined with power cogeneration.

    Science.gov (United States)

    Bechara, Rami; Gomez, Adrien; Saint-Antonin, Valérie; Schweitzer, Jean-Marc; Maréchal, François

    2016-08-01

    The application of methodologies for the optimal design of integrated processes has seen increased interest in literature. This article builds on previous works and applies a systematic methodology to an integrated first and second generation ethanol production plant with power cogeneration. The methodology breaks into process simulation, heat integration, thermo-economic evaluation, exergy efficiency vs. capital costs, multi-variable, evolutionary optimization, and process selection via profitability maximization. Optimization generated Pareto solutions with exergy efficiency ranging between 39.2% and 44.4% and capital costs from 210M$ to 390M$. The Net Present Value was positive for only two scenarios and for low efficiency, low hydrolysis points. The minimum cellulosic ethanol selling price was sought to obtain a maximum NPV of zero for high efficiency, high hydrolysis alternatives. The obtained optimal configuration presented maximum exergy efficiency, hydrolyzed bagasse fraction, capital costs and ethanol production rate, and minimum cooling water consumption and power production rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Design of a modular cogeneration plant to supply residential buildings; Dimensionierung eines Blockheizkraftwerkes zur Versorgung einer Wohnsiedlung

    Energy Technology Data Exchange (ETDEWEB)

    Marquardt, R.

    2000-03-01

    Excel tables are presented for fast integral calculation of all energetic and monetary parameters required for calculating the economic efficiency of a cogeneration plant. The Excel programming is more detailed than the method of calculation specified in VDI 2067 in that it also provides potential energy savings,carbon dioxide reduction and exergetic calculations. Influencing parameters like technical data, energy consumption data, fuel properties, and the cost structure of electricity and heat supply can be freely chosen so as to enable maximum parameter variation and an analysis of their influence on the result. [German] Mit der vorliegenden Arbeit wurde ein Instrument in Form von Excel-Tabellen erstellt, das eine schnelle integrale Berechnung aller energetischen und monetaeren Ergebnisgroessen ermoeglicht, die beim Einsatz eines BHKW zur Versorgung einer Bedarfsstruktur im Vergleich zu einer konventionellen getrennten Energiebereitstellung von Interesse sind. Die Excel-Programmierung geht dabei ueber die Abbildung des in der VDI 2067 beschriebenen Berechnungsverfahrens hinaus und liefert neben der Berechnung der Waermebereitstellungskosten auch die Ermittlung von Energieeinspar-, CO{sub 2}-Minderungspotentialen sowie eine exergetische Betrachtung der Ergebnisse. Alle auf das Ergebnis einwirkende Parameter wie technische Anlagendaten, Energiebedarfswerte, Brennstoffeigenschaften, Kostenstruktur der Elektrizitaets- und Waermeversorgung u.a. sind prinzipiell frei waehlbar. So wurde sichergestellt, dass eine Variation verschiedener Parameter moeglich ist und deren Einfluss auf das Ergebnis analysiert werden kann. (orig.)

  3. Feasibility study on the St. Petersburg City heat and electric cogeneration plant No.2, etc. scrap and build project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of reducing greenhouse effect gas emissions in line with the Joint Implementation, a survey was made of the scrap and build project for the superannuated Central Heat Power Station in St. Petersburg City. The survey team visited the relevant sites twice during 1999. The team drafted an improvement plan afterwards and presented it to the Russian counterpart, LENENEGRO. Based on the discussions with LENENEGRO, it was determined that the proposed combined cycle cogeneration plant would contain three 67MW-class gas turbines, three heat recovery steam generators and one back pressure turbine to achieve the generation capacity of approximately 200MW and heat supply capacity of 200G cal/hr. The total investment required for this project is about 140 million dollars. The term of the construction work is estimated at 36 months. It is estimated that the implementation of the project will reduce 1,481,979 tons of CO2 per year, or a total of 40,013,434 tons in 27 years after the commencement of operation. In addition, the terminal power generation efficiency will be improved from the current 18.68% to 41%, which leads to an annual fuel saving of 546,301 tons of crude oil or its equivalent. (NEDO)

  4. A Geothermal Energy Supported Gas-steam Cogeneration Unit as a Possible Replacement for the Old Part of a Municipal CHP Plant (TEKO

    Directory of Open Access Journals (Sweden)

    L. Böszörményi

    2001-01-01

    Full Text Available The need for more intensive utilization of local renewable energy sources is indisputable. Under the current economic circumstances their competitiveness in comparison with fossil fuels is rather low, if we do not take into account environmental considerations. Integrating geothermal sources into combined heat and power production in a municipal CHP plant would be an excellent solution to this problem. This concept could lead to an innovative type of power plant - a gas-steam cycle based, geothermal energy supported cogeneration unit.

  5. Simulaton of the Avedøreværket Unit 1 Cogeneration Plant with DNA

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Houbak, Niels

    2003-01-01

    The simulator contest proposed for the ECOS 2003 conference has been solved using the DNA energy system simulator. The contest concerns the steam process of the Avedøreværket Unit 1 (AVV1) power plant. The plant is a 250 MWCHP plant with a maximum district heat production of 330 MJ/s. The plant has...... a net electric efficiency of 42% and a maximum energy utilization of 92%. In this paper it is demonstrated, that the DNA model of AVV1 can calculate the whole flow sheet balance at any load point, i.e., any possible combination of power production and district heat production. The paper also contains...

  6. Modeling and Control of Cogeneration Power Plants: A Hybrid System Approach

    NARCIS (Netherlands)

    G. Ferrari-Trecate (Giancarlo); E. Gallestey (Eduardo); P. Letizia (Paolo); M. Spedicato (Matteo); M. Morari (Manfred); M. Antoine (Marc)

    2004-01-01

    textabstractIn this paper the short term scheduling optimization of a combined cycle power plant is accomplished by exploiting hybrid systems, i.e. systems evolving according to continuous dynamics, discrete dynamics, and logic rules. Discrete features of a power plant are, for instance, the

  7. District heating system of Belgrade supplied from the co-generation plant 'Obrenovac' (Yugoslavia)

    International Nuclear Information System (INIS)

    Tomic, P.; Dobric, Z.; Studovic, M.

    2000-01-01

    The paper presents most relevant technical and economic features of the Project called 'System for supplying Belgrade with heat' (SDGB) from the thermal power plant 'Obrenovac', based on domestic coal and reconstruction of condensing power plant for combined generation of electricity and heat for the needs of municipal energy consumption. The system is designed for transport thermal energy, with capacity of 730 MJ/s from the Thermal Power Plant 'Nikola Tesla' / A to the existing heat plant 'Novi Beograd' based on the natural gas. The paper also gives the comparison of most important technical and economic features of 'SDGB' Project with the similar Project of District Heating System for supplying Prague with the thermal energy from Thermal Power Plant Melnik. (Author)

  8. Coal fired air turbine cogeneration

    Science.gov (United States)

    Foster-Pegg, R. W.

    Fuel options and generator configurations for installation of cogenerator equipment are reviewed, noting that the use of oil or gas may be precluded by cost or legislation within the lifetime of any cogeneration equipment yet to be installed. A coal fueled air turbine cogenerator plant is described, which uses external combustion in a limestone bed at atmospheric pressure and in which air tubes are sunk to gain heat for a gas turbine. The limestone in the 26 MW unit absorbs sulfur from the coal, and can be replaced by other sorbents depending on types of coal available and stringency of local environmental regulations. Low temperature combustion reduces NOx formation and release of alkali salts and corrosion. The air heat is exhausted through a heat recovery boiler to produce process steam, then can be refed into the combustion chamber to satisfy preheat requirements. All parts of the cogenerator are designed to withstand full combustion temperature (1500 F) in the event of air flow stoppage. Costs are compared with those of a coal fired boiler and purchased power, and it is shown that the increased capital requirements for cogenerator apparatus will yield a 2.8 year payback. Detailed flow charts, diagrams and costs schedules are included.

  9. Cogeneration techniques; Les techniques de cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-10-01

    This dossier about cogeneration techniques comprises 12 parts dealing successively with: the advantages of cogeneration (examples of installations, electrical and thermal efficiency); the combustion turbine (principle, performances, types); the alternative internal combustion engines (principle, types, rotation speed, comparative performances); the different configurations of cogeneration installations based on alternative engines and based on steam turbines (coal, heavy fuel and natural gas-fueled turbines); the environmental constraints of combustion turbines (pollutants, techniques of reduction of pollutant emissions); the environmental constraints of alternative internal combustion engines (gas and diesel engines); cogeneration and energy saving; the techniques of reduction of pollutant emissions (pollutants, unburnt hydrocarbons, primary and secondary (catalytic) techniques, post-combustion); the most-advanced configurations of cogeneration installations for enhanced performances (counter-pressure turbines, massive steam injection cycles, turbo-chargers); comparison between the performances of the different cogeneration techniques; the tri-generation technique (compression and absorption cycles). (J.S.)

  10. Cogeneration system simulation/optimization

    International Nuclear Information System (INIS)

    Puppa, B.A.; Chandrashekar, M.

    1992-01-01

    Companies are increasingly turning to computer software programs to improve and streamline the analysis o cogeneration systems. This paper introduces a computer program which originated with research at the University of Waterloo. The program can simulate and optimize any type of layout of cogeneration plant. An application of the program to a cogeneration feasibility study for a university campus is described. The Steam and Power Plant Optimization System (SAPPOS) is a PC software package which allows users to model any type of steam/power plant on a component-by-component basis. Individual energy/steam balances can be done quickly to model any scenario. A typical days per month cogeneration simulation can also be carried out to provide a detailed monthly cash flow and energy forecast. This paper reports that SAPPOS can be used for scoping, feasibility, and preliminary design work, along with financial studies, gas contract studies, and optimizing the operation of completed plants. In the feasibility study presented, SAPPOS is used to evaluate both diesel engine and gas turbine combined cycle options

  11. Fuel cost charged to desalters in co-generation power-desalting plants

    Energy Technology Data Exchange (ETDEWEB)

    Darwish, M.A. [Kuwait Univ. (Kuwait)

    1995-05-01

    In combined power-desalting plants, high available steam (at high pressure and temperature) is expanded first in a steam turbine (and thus produces work) before its extraction (from the turbine) as a heat source to the desalters. The amount of energy consumption charged to the predominantly used multi-stage flash (MSF) desalter in this combined heat and power plant is a question of great concern in the Gulf area. The following are among the methods used to answer this question: (i) the available energy of the heat supplied to the desalter; (ii) work loss from the lower pressure stages of the steam turbine due to steam extracted to the desalter; (iii) energy charged if a separate boiler was used to supply the desalter with its required heat; and (iv) the excess energy supplied to the combined power desalting plant as compared to a single purpose power plant producing the same power output. There would be a different rating method of the power producing process associated with any of the above mentioned charging methods. In this paper, the MSF desalting method and its power consumption are outlined, together with the rating method of the power-desalting plants and the energy charged to the desalter methods. These rating methods are applied to real cases of dual purpose plants working in Kuwait. (author)

  12. Integration of windpower using cogeneration plants under decreasing space heating consumption

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2004-01-01

    Energy systems are becoming increasingsly complex with many interdependencies between energy sources, various energy transformation technologies, energy carrieers and end-use energy systems. With the present technologies, a certain production on large-scale power plants is thus required to supply...... power that may be integrated into the electricity system. However, analyses reveal that even though this is an issue, the fuels savings from heat savings by far exceed the loss in utilisation of wind power....

  13. Production of thermal and electrical energy in the small and middle cogeneration gas electrical plants, v. 16(61)

    International Nuclear Information System (INIS)

    Vasilevski, Gotse; Krstevski, Gjorgje

    2008-01-01

    Production of thermal and electrical energy leads to numerous problems which need to be solved in the large energy systems. Some problems as consumption of predefined energy (electrical energy or thermal energy as hot water or steam) in time and space domain can be solved through the usage of cogeneration units with high efficiency parameters. (Author)

  14. Environmental analysis of a potential district heating network powered by a large-scale cogeneration plant.

    Science.gov (United States)

    Ravina, Marco; Panepinto, Deborah; Zanetti, Maria Chiara; Genon, Giuseppe

    2017-05-01

    Among the solutions for the achievement of environmental sustainability in the energy sector, district heating (DH) with combined heat and power (CHP) systems is increasingly being used. The Italian city of Turin is in a leading position in this field, having one of the largest DH networks in Europe. The aim of this work is the analysis of a further development of the network, addressed to reduce the presence of pollutants in a city that has long been subject to high concentration levels. The environmental compatibility of this intervention, especially in terms of nitrogen oxides (NO x ) and particulate matter (PM) emissions, is evaluated. The pollutants dispersion is estimated using the CALPUFF model. The forecasting scenario is created firstly by simulating the energy production of the main generation plants in response to the estimated heat demand, and secondly by investigating the amount and the dispersion of pollutants removed due to the elimination of the centralized residential heaters. The results show a future reduction in ground level average NO x concentration ranging between 0.2 and 4 μg/m 3 . The concentration of PM remains almost unchanged. Measures are then taken to lower the uncertainty in the simulation scenarios. This study provides important information on the effects of a change of the energy configuration on air quality in an urban area. The proposed methodological approach is comprehensive and repeatable.

  15. Meeting changing conditoins at the Rhode Island Medical Center cogeneration plant

    International Nuclear Information System (INIS)

    Galamaga, D.P.; Bowen, P.T.

    1993-01-01

    The Rhode Island Department of Mental Health, Retardation and Hospitals is one state department in Rhode Island whose basic function is to provide services to seriously disabled individuals throughout the state. Savings in operating expenses from the Rhode Island Medical Center Central Power Plant have accruded to provide operating funds for the major programs. Operating under a Director who reports to the Governor of Rhode Island, the Department has three major divisions, approximately 2500 employees, and a budget of 200 million dollars. Its operations extend throughout the state and the major focus for hospital or institutional levels of care reside in three major locations, the Dr. U.E. Zambarano Memorial Hospital in northern Rhode Island, the Dr. Joseph Ladd Center in southern Rhode Island, and the Rhode Island Medical Center in the middle of the state. Besides these institution-based operations, the Department sponsors a wide range of rehabilitative programming in the community other through direct operations of facilities such as group homes or through contracts with private non-profit providers of service

  16. Boehringer Ingelheim Promeco contemplates the benefits of cogeneration in its new plant; Boehringer Ingelheim Promeco contempla beneficios de la cogeneracion para su nueva planta

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Esparza, R. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Khouri Solis, A. [Boehringer Ingelheim Promeco, Mexico, D. F. (Mexico)

    1997-12-31

    This paper presents the results of the feasibility study performed in BOEHRINGER INGELHEIM PROMECO to determine the benefits that a cogeneration system could render in satisfying the energy demand of its plant currently being expanded. The results showed that in accordance with the operation mode of the already expanded plant, the highest benefits could be obtained of a cogeneration system with a capacity of 1,600 Kw that would partially satisfy the thermal and electrical demands of BOEHRINGER INGELHEIM PROMECO. [Espanol] El presente articulo presenta los resultados de factibilidad que se realizo en Boehringer Ingelheim Promeco para determinar los beneficios que podria rendir un sistema de cogeneracion al satisfacer las demandas energeticas de su planta actualmente en ampliacion. Los resultados mostraron que de acuerdo al modo de operacion de la planta ya ampliada, los beneficios mas altos se obtendrian de un sistema de cogeneracion con capacidad de 1,600 kW que satisfaria parcialmente las demandas termicas y electricas de Boehringer Ingelheim Promeco.

  17. Optimization of cogeneration thermal power units

    Science.gov (United States)

    Kler, A. M.; Marinchenko, A. Yu.; Potanina, Yu. M.

    2009-09-01

    We present a procedure for comparing the efficiencies of cogeneration thermal power units that takes variable conditions of their operation into account. A combined-cycle plant operating in accordance with the STIG cycle (i.e., with mixing of working fluids), a gas turbine unit equipped with a gas economizer, and a steam turbine unit equipped with a backpressure turbine are compared during their operation as part of a cogeneration station.

  18. Introduction to cogeneration; Introducao a cogeracao

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Luiz Augusto Horta; Martins, Andre Luiz Silva [Escola Federal de Engenharia de Itajuba, MG (Brazil)

    1997-07-01

    This work presents a general view of cogeneration. The paper approaches the development of cogeneration, technological aspects, the cogeneration in Brazil, economical aspects, performance of cogeneration systems, viability, costs, cogeneration potentials and technological trends.

  19. CDM potential of bagasse cogeneration in India

    International Nuclear Information System (INIS)

    Purohit, Pallav; Michaelowa, Axel

    2007-01-01

    So far, the cumulative capacity of renewable energy systems such as bagasse cogeneration in India is far below their theoretical potential despite government subsidy programmes. One of the major barriers is the high investment cost of these systems. The Clean Development Mechanism (CDM) provides industrialized countries with an incentive to invest in emission reduction projects in developing countries to achieve a reduction in CO 2 emissions at lowest cost that also promotes sustainable development in the host country. Bagasse cogeneration projects could be of interest under the CDM because they directly displace greenhouse gas emissions while contributing to sustainable rural development. This study assesses the maximum theoretical as well as the realistically achievable CDM potential of bagasse cogeneration in India. Our estimates indicate that there is a vast theoretical potential of CO 2 mitigation by the use of bagasse for power generation through cogeneration process in India. The preliminary results indicate that the annual gross potential availability of bagasse in India is more than 67 million tonnes (MT). The potential of electricity generation through bagasse cogeneration in India is estimated to be around 34 TWh i.e. about 5575 MW in terms of the plant capacity. The annual CER potential of bagasse cogeneration in India could theoretically reach 28 MT. Under more realistic assumptions about diffusion of bagasse cogeneration based on past experiences with the government-run programmes, annual CER volumes by 2012 could reach 20-26 million. The projections based on the past diffusion trend indicate that in India, even with highly favorable assumptions, the dissemination of bagasse cogeneration for power generation is not likely to reach its maximum estimated potential in another 20 years. CDM could help to achieve the maximum utilization potential more rapidly as compared to the current diffusion trend if supportive policies are introduced

  20. Cogeneration: Key feasibility analysis parameters

    International Nuclear Information System (INIS)

    Coslovi, S.; Zulian, A.

    1992-01-01

    This paper first reviews the essential requirements, in terms of scope, objectives and methods, of technical/economic feasibility analyses applied to cogeneration systems proposed for industrial plants in Italy. Attention is given to the influence on overall feasibility of the following factors: electric power and fuel costs, equipment coefficients of performance, operating schedules, maintenance costs, Italian Government taxes and financial and legal incentives. Through an examination of several feasibility studies that were done on cogeneration proposals relative to different industrial sectors, a sensitivity analysis is performed on the effects of varying the weights of different cost benefit analysis parameters. With the use of statistical analyses, standard deviations are then determined for key analysis parameters, and guidelines are suggested for analysis simplifications

  1. Cogeneration. Energy efficiency - Micro-cogeneration

    International Nuclear Information System (INIS)

    Boudellal, M.

    2010-01-01

    Depletion of natural resources and of non-renewable energy sources, pollution, greenhouse effect, increasing energy needs: energy efficiency is a major topic implying a better use of the available primary energies. In front of these challenges, cogeneration - i.e. the joint production of electricity and heat, and, at a local or individual scale, micro-cogeneration - can appear as interesting alternatives. This book presents in a detailed manner: the present day and future energy stakes; the different types of micro-cogeneration units (internal combustion engines, Stirling engine, fuel cell..), and the available models or the models at the design stage; the different usable fuels (natural gas, wood, biogas..); the optimization rules of a facility; the costs and amortizations; and some examples of facilities. (J.S.)

  2. Biomass cogeneration. A business assessment

    Energy Technology Data Exchange (ETDEWEB)

    Skelton, J.C.

    1981-11-01

    This guide serves as an overview of the biomass cogeneration area and provides direction for more detailed analysis. The business assessment is based in part on discussions with key officials from firms that have adopted biomass cogeneration systems and from organizations such as utilities, state and federal agencies, and banks that would be directly involved in a biomass cogeneration project. The guide is organized into five chapters: biomass cogeneration systems, biomass cogeneration business considerations, biomass cogeneration economics, biomass cogeneration project planning, and case studies.

  3. Analysis reports on the ecotoxicological evaluation of discharges of spent water at the cogeneration/central heating plants Alloeverket, Borgaas, Haendeloeverket, Moelnlycke, Saevenaes and Aelmhult; Analysrapporter avseende ekotoxikologisk bedoemning av utslaepp av utgaaende vatten vid Alloeverket, Borgaas, Haendeloeverket, Moelnlycke, Saevenaes och Aelmhult

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jonas; Axby, Fredrik; Persson, Maarten; Rossander, Annelie; Schultz, Emma; Svaerd, Sara [Carl Bro AB, Kristianstad (Sweden)

    2007-04-15

    The discharges to water at six biofuelled Swedish cogeneration/district heating plants are evaluated in light of the EU Water Framework Directive concerning ecotoxicological impacts. Ecotoxicological data for the 33 prioritized substances are also reviewed.

  4. Smart intermittency-friendly cogeneration: Techno-economic performance of innovative double storage concept for integrating compression heat pumps in distributed cogeneration

    DEFF Research Database (Denmark)

    Blarke, Morten

    2011-01-01

    plants may adapt their plant design and operational strategy to improve the co-existence between cogeneration and intermittent renewables. A novel intermittency-friendly and super-efficient concept in cogeneration is presented that involves integrating a high-pressure compression heat pump using heat...... cogeneration plants rather than central power plants are giving way for wind power in the electricity mix. Could intermittent renewables be a threat to the system-wide energy, economic and environmental benefits that distributed cogeneration have to offer? This paper investigates how existing cogeneration...... recovered from flue gasses as the only low-temperature heat source, furthermore applying an intermediate cold storage allowing for non-concurrent operation of heat pump and cogeneration unit. The novel concept is subject to a detailed techno-economic comparative modelling and analysis, hich finds...

  5. Cogeneration of electric power in the sugar and alcohol sectors: registration of the power plants in Sao Paulo, Brazil; Cogeracao de energia eletrica no setor sucroalcooleiro: cadastro das usinas em Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Gustavo Goncalves [Federacao das Industrias do Estado de Sao Paulo (FIESP), Sao Paulo, SP (Brazil); Moreira, Helemilton Rios; Silva, Edison da [Agencia Reguladora de Saneamento e Energia do Estado de Sao Paulo (ARSESP), SP (Brazil)

    2008-07-01

    One of the major difficult for the planning of co-generation industry of electricity from the sugar cane bagasse is the determination of their true potential. This question comes up, especially in the lack of information about the sugar and ethanol facilities, therefore for the study of potential, we can not just focus on the issue of the cane grinding, but also in technology, the configuration of the power plant and its capacity to export energy. This paper presents a proposal to minimize this difficulty, detailing a solution dedicated to the development of a database for the registration and monitoring of these plants, part of a series of actions regarding in the Understanding Protocol for the promotion of co-generation of bagasse, signed between FIESP and the Government of the State of Sao Paulo. (author)

  6. Cogeneration and North Carolina

    Energy Technology Data Exchange (ETDEWEB)

    Kohl, J. [ed.

    1979-01-01

    A separate abstract was prepared for each of 18 individual presentations. Appendices include lists of participants, speakers, and session chairmen plus California and North Carolina reports and legislation dealing with cogeneration.

  7. Cogeneration markets in Ontario

    International Nuclear Information System (INIS)

    Poredos, S.

    1993-01-01

    Cogeneration offers a key strategy which supports global competitiveness for Ontario businesses, encourages energy efficiency and environmental protection, and offers natural gas utilities and producers stable long-term incremental markets. By supporting cogeneration projects, electric utilities will benefit from increased flexibility. Natural gas is the fuel of choice for cogeneration, which can in most cases be easily integrated into existing operations. In Ontario, electric demand grew along with the gross domestic product until 1990, but has decreased with the recent economic recession. The provincial utility Ontario Hydro is resizing itself to stabilize total rate increases of 30% over the last three years and supporting reduction of its high debt load. Rate increases are supposed to be limited but this may be difficult to achieve without further cost-cutting measures. Cogeneration opportunities exist with many institutional and industrial customers who are trying to remain globally competitive by cutting operating costs. In general, cogeneration can save 20% or more of total annual energy costs. Due to excess capacity, Ontario Hydro is not willing to purchase electric power, thus only electric load displacement projects are valid at this time. This will reduce overall savings due to economies of scale. In southwestern Ontario, Union Gas Ltd. has been successful in developing 40 MW of electric displacement projects, providing a total load of 5 billion ft 3 of natural gas (50% of which is incremental). Over 3,000 MW of technical cogeneration potential is estimated to exist in the Union Gas franchise area

  8. Global environment and cogeneration

    International Nuclear Information System (INIS)

    Miyahara, Atsushi

    1992-01-01

    The environment problems on global scale have been highlighted in addition to the local problems due to the rapid increase of population, the increase of energy demand and so on. The global environment summit was held in Brazil. Now, global environment problems are the problems for mankind, and their importance seems to increase toward 21st century. In such circumstances, cogeneration can reduce carbon dioxide emission in addition to energy conservation, therefore, attention has been paid as the countermeasure for global environment. The background of global environment problems is explained. As to the effectiveness of cogeneration for global environment, the suitability of city gas to environment, energy conservation, the reduction of carbon dioxide and nitrogen oxides emission are discussed. As for the state of spread of cogeneration, as of March, 1992, those of 2250 MW in terms of power generation capacity have been installed in Japan. It is forecast that cogeneration will increase hereafter. As the future systems of cogeneration, city and industry energy center conception, industrial repowering, multiple house cogeneration and fuel cells are described. (K.I.)

  9. Thermal-economic analysis of cogeneration systems

    International Nuclear Information System (INIS)

    Walter, A.C.S.; Bajay, S.V.

    1992-01-01

    Approximately 80 countries produce sugar, and fortuitously alcohol, from sugar cane. In all these countries the cogeneration technology of steam turbines is utilized, although almost always inefficient. The greater potential of cogeneration in Brazil is in sugar and alcohol sector, because of the use of sugar cane bagasse as combustible. This work applies the techniques of simulation and economic analysis to different configuration of plants, to determine power generation and associated costs of each alternative. The application of the same procedure at operating condition of several configurations in transient system permits the determination of production profile of exceeding during one day. (C.M.)

  10. Intermittency-friendly and high-efficiency cogeneration

    DEFF Research Database (Denmark)

    Blarke, Morten; Dotzauer, Erik

    2011-01-01

    This paper develops, implements, and applies a mathematical model for economic unit dispatch for a novel cogeneration concept (CHP-HP-FG-CS (CHP with compression heat pump and cold storage using flue gas heat)) that increases the plant’s operational flexibility. The CHP-HP-FG-CS concept is a high......-temperature heat source, and an intermediate cold thermal storage allowing for non-concurrent operation of the cogeneration unit and the heat pump unit. The model is applied for a paradigmatic case study that shows how the integration of a heat pump affects the operational strategy of a cogeneration plant......-efficiency and widely applicable option in distributed cogeneration better supporting the co-existence between cogenerators and intermittent renewables in the energy system. The concept involves integrating an efficient high-temperature compression heat pump that uses only waste heat recovered from flue gases as low...

  11. Industrial Cogeneration Optimization Program: A summary of two studies

    Science.gov (United States)

    1981-08-01

    Two industrial cogeneration optimization programs were performed to examine the economic and energy saving impacts of adding cogeneration to site specific plants in the chemical, food, pulp and paper, petroleum refining, and textile industries. Industrial cogeneration is reviewed. The two parallel ICOP studies are described. The five industrial sectors are also described, followed by highlights of each of the site specific case studies. Steam turbine cogeneration systems fired by coal or alternative fuels are generally the most attractive in terms of economic performance and oil/gas savings potential. Of the 15 cogeneration systems selected as optimum in the ICOP studies, 11 were coal or wood fired steam turbines. By contrast, gas turbines, combined cycles, and diesel engines, which are limited to oil or gas firing, are usually less economical.

  12. External financing of projects on cogeneration

    International Nuclear Information System (INIS)

    Contreras Olmedo, D.

    1993-01-01

    The Spanish Institute for Energy Saving and Diversification (IDAE), provides technical advisement and economical support to those industries requiring an improvement in the energy efficiency of their production chain. This paper focusses on administrative procedures to get external financing as one way to undertake the construction of cogeneration plants. Relationships among user, promoter and financier should be developed according to the outlined procedures. (Author)

  13. Feasibility study for new ecolabels according to ISO 14024 (type I) within the product group: small cogeneration plants; Machbarkeitsstudie fuer neue Umweltzeichen in Anlehnung an ISO 14024 (Type I) fuer die Produktgruppe: Kleine Blockheizkraftwerk-Module

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E.; Hirschl, B.; Kaliske, J. [Institut fuer Oekologische Wirtschaftsforschung (IOEW) gGmbH, Berlin (Germany); Reese, I.; Grimpe, T. [Hamburg Gas Consult (HGC) GmbH (Germany)

    2000-11-02

    This study is a feasibility study according to ISO 14024. It deals with the question whether an ecolabel is suitable for small cogeneration plants and how concrete criteria for an ecolabel on cogeneration plants could be specified. The study began with a comprehensive market analysis in order to identify possible plants for which an ecolabel would make sense. In the main part of the study, the environmental relevance of the chosen plants was analysed. For this analysis, plant manufacturers were interviewed and a comparison between cogeneration plants and heating plants was carried out. On the basis of this analysis, it was possible to derive a number of criteria which were presented and discussed in an expert talk by various company representatives and experts in this field. As a result of the expert talk and the investigation process as a whole, the introduction of an ecolabel for small cogeneration plants can be recommended. The proposed certification principles comprise requirements regarding the compliance with directives, efficient energy use (electrical and overall efficiency factor under partial load and nominal load, mentioning the plant's supplementary energy consumption), emission values for CO, NO{sub x}, dust and organic substances, sound emissions, the offer of maintenance contracts, plant take back obligations, as well as requirements with regard to the operating instructions. The transcription of the label is proposed as 'Ecolabel. because energy-efficient'. Besides cogeneration plants based on engines, the study also focused on small stationary fuel cells. They are currently in the development phase and are tested within the scope of several field studies. Compared to conventional heating plants and cogeneration plants powered by engines, this new technology promises clear ecological advantages and constitutes a future alternative to engine powered equivalents. Faced by the current state of development and the limited quality of the

  14. The cogeneration as an alternative of conservation of energy or increased productivity in industrial asphalt plants; A cogeracao como alternativa de conservacao de energia ou aumento da produtividade industrial em usinas de asfalto

    Energy Technology Data Exchange (ETDEWEB)

    Mello, Liodoro de [Universidade Federal de Itajuba (UNIFEI), Santos, SP (Brazil)], Email: mellostopa@pop.com.br; Souza, Marcelo de Oliveira e [Centrais Eletricas Brasileira S.A - ELETROBRAS, Brasilia, DF (Brazil); Mello, Eliane Stopa de

    2006-07-01

    The paper presents a detailed study on the implantation of the combined and simultaneous generation of usable energy (cogeneration) in industrial units that provide support for the flow of wealth to the country, across roads and highways, as is the case of plant Asphalt EMPAV. The study, by the sensitivity analysis of economic and financial, completed in 2004, showed the feasibility of cogeneration system for the company. The fact is that this study would not have been exhaustively discussed, otherwise would be institutional actions towards improving the completion of work. In order to resume this discussion in this article was concerned to measure the monetary losses, especially energy, during the period 2004-2006 the production of asphalt for the conventional way.

  15. Cogeneration in the former Soviet Union

    International Nuclear Information System (INIS)

    Horak, W.C.

    1997-01-01

    The former Soviet Union made a major commitment to Cogeneration. The scale and nature of this commitment created a system conceptually different from Cogeneration in the west. The differences were both in scale, in political commitment, and in socio economic impact. This paper addresses some of the largest scale Cogeneration programs, the technology, and the residual impact of these programs. The integration of the Cogeneration and nuclear programs is a key focus of the paper. Soviet designed nuclear power plants were designed to produce both electricity and heat for residential and industrial uses. Energy systems used to implement this design approach are discussed. The significant dependence on these units for heat created an urgent need for continued operation during the winter. Electricity and heat are also produced in nuclear weapons production facilities, as well as power plants. The Soviets also had designed, and initiated construction of a number of nuclear power plants open-quotes ATETsclose quotes optimized for production of heat as well as electricity. These were canceled

  16. The California cogeneration success story

    International Nuclear Information System (INIS)

    Neiggemann, M.F.

    1992-01-01

    This chapter describes the involvement of Southern California Gas Company(SoCalGas) in the promotion and demonstration of the benefits of cogeneration in California. The topics covered in this chapter are market strategy, cogeneration program objectives, cogeneration program, incentive cofunding, special gas rate, special service priority, special gas pressure and main options, advertising, promotional brochures and handbooks, technical support, program accomplishments, cogeneration outlook, and reasons for success of the program

  17. The cogeneration market in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Watabe, Masaki [Cogeneration Research Society of Japan, Tokyo (Japan). Research Dept.

    1997-09-01

    Conventional power generation is only around 35% efficient at demand side in Japan. Cogeneration increases the overall energy efficiency up to 85%. Other merits of cogeneration are energy saving, improvement of the environment, greenhouse gas emission (CO{sub 2}) can be reduced. The energy conditions in Japan are overviewed and the trends for cogeneration - both commercial and industrial - are evaluated. Finally, statutory regulations regarding cogeneration systems are considered. (R.P.)

  18. Energetic, exergetic, thermoeconomic and environmental analysis of various systems for the cogeneration of biogas produced by an urban wastewater treatment plant UWTP

    Energy Technology Data Exchange (ETDEWEB)

    Coble, J.J. [Nebrija Univ., Madrid (Spain). Industrial Engineering Dept.; Contreras, A. [Industrial Engineering College, Madrid (Spain). Chemistry Dept.

    2010-07-01

    General awareness that the world's energy resources are limited has meant that it is increasingly important to examine energy-saving devices and fuels more closely, in order to use our limited available resources in a more sustainable manner. With this in mind, we studied biogas from a UWTP, because it is a renewable fuel with a neutral contribution to CO2 emissions. We compared two technologies for using biogas as an energy source: cogeneration using either motor-generators or phosphoric acid fuel cells. The comparison was made from the energetic, exergetic, thermo-economic and environmental points of view, internalizing all the costs involved in each case. We used data supplied by the UWTP at the City of Madrid Plant Nursery, which uses motor-generators, and the UWTPs in Portland, Oregon, and in Red Hook, New York, which use a phosphoric acid fuel cell. The joint work carried out has been divided into three parts for publication purposes, and we present here the first of these, which refers to the energy analysis. (orig.)

  19. Cogeneration feasibility study in the Gulf States Utilities service area

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    Sites in the Gulf States Utilities service are considered for cogeneration feasibility studies. The sources of steam considered for the Orange, Texas and Geismar, Lake Charles, and North Baton Rouge, Louisiana sites include oil, coal, HTGR steamers, consolidated nuclear steam system, atmospheric fluidized-bed coal combustion, and coal gasification. Concepts concerning cogeneration fuel systems were categorized by technical applicability as: current technology (pulverized coal-fired boilers and fuel oil-fired boilers), advanced technology under development (HTGR steamers and the CNSS), and advanced technology for future development (atmospheric fluidized-bed boilers and coal gasification). In addition to providing data on cogeneration plant generally useful in the US, the study determined the technical and economic feasibility of steam and electric power cogeneration using coal and nuclear fuels for localized industrial complexes. Details on site selection, plant descriptions, cost estimates, economic analysis, and plant schedule and implementation. (MCW)

  20. Grid connected integrated community energy system. Phase II: final stage 2 report. Outline specifications of cogeneration plant

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-22

    Specifications are presented for major components of the dual-purpose power plant to be located on the University of Minnesota campus. This power plant will supply steam and electric power to a proposed grid-connected Integrated Community Energy System. The capital costs and capital budget for the power plant and specifications for auxiliary equipment, such as the interconnecting heat tunnel, are included. (LCL)

  1. Grid connected integrated community energy system. Phase II: final stage 2 report. Outline specifications of cogeneration plant; continued

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-22

    Specifications are presented for the electrical equipment, site preparation, building construction and mechanical systems for a dual-purpose power plant to be located on the University of Minnesota campus. This power plant will supply steam and electrical power to a grid-connected Integrated Community Energy System. (LCL)

  2. Grid connected integrated community energy system. Phase II: final stage 2 report. Preliminary design of cogeneration plant

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-22

    The preliminary design of a dual-purpose power plant to be located on the University of Minnesota is described. This coal-fired plant will produce steam and electric power for a grid-connected Integrated Community Energy System. (LCL)

  3. Industrial cogeneration optimization program. Final report, September 1979

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Jerry; McWhinney, Jr., Robert T.

    1980-01-01

    This study program is part of the DOE Integrated Industry Cogeneration Program to optimize, evaluate, and demonstrate cogeneration systems, with direct participation of the industries most affected. One objective is to characterize five major energy-intensive industries with respect to their energy-use profiles. The industries are: petroleum refining and related industries, textile mill products, paper and allied products, chemicals and allied products, and food and kindred products. Another objective is to select optimum cogeneration systems for site-specific reference case plants in terms of maximum energy savings subject to given return on investment hurdle rates. Analyses were made that define the range of optimal cogeneration systems for each reference-case plant considering technology applicability, economic factors, and energy savings by type of fuel. This study also provides guidance to other parts of the program through information developed with regard to component development requirements, institutional and regulatory barriers, as well as fuel use and environmental considerations. (MCW)

  4. The Use of Spark Ignition Engine in Domestic Cogeneration

    Directory of Open Access Journals (Sweden)

    Feiza Memet

    2009-10-01

    Full Text Available Cogeneration plants are strongly sustained by EU energy policies, one of the best beneficiary of this technology being residential buildings. This paper focus on spark ignition engine as a cogeneration application in order to supply energy for domestic consumers. Are considered two aspects of this solution: the energetic aspect and the environmental one. The energetic aspect deals with the energetic ratios, while the environmental aspect refers to the nitrogen oxide and carbon monoxide emissions.

  5. Technical overview of cogeneration: the hardware, the industries, the potential development

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    Because the by-product heat from a power-conversion process is captured for productive use in a cogeneration system, instead of exhausted to the environment as it is in a conventional power plant, cogeneration represents an important energy-conservation technique. By cogenerating, an industrial plant can save the fuel that would have been needed to produce the amount of heat captured. Recognizing the significant energy-savings potential offered by cogeneration, DOE has undertaken a major R, D, and D program to investigate and promote cogeneration in industry. Resource Planning Associates, Inc. (RPA), has been working to accomplish four of the program's objectives: (1) survey current, near state-of-the-art, and future cogeneration equipment, and identify any gaps or deficiencies; (2) characterize the energy requirements of the manufacturing sectors of five of the country's most energy-intensive industries - chemical, petroleum refining, paper and pulp, textiles, and food; (3) identify principal targets for, and barriers to, the increased market development of cogeneration systems; and (4) estimate the potential maximum and the probable energy savings that could be achieved in the five selected industries through cogeneration. In investigating cogeneration hardware, three specific technologies - steam turbines, gas turbines, and diesel engines - were emphasized. It is estimated that the widespread application of cogeneration technology in the five industries studied could result in a maximum potential savings of 2.4 million barrels of oil equivalent per day (or a maximum incremental capacity of 140,000 MWe) by 1985.

  6. Novel, cost-effective configurations of combined power plants for small-scale cogeneration from biomass: Feasibility study and performance optimization

    International Nuclear Information System (INIS)

    Amirante, Riccardo; Tamburrano, Paolo

    2015-01-01

    Highlights: • A cheap small combined cycle for cogeneration from biomass is proposed. • An optimization procedure is utilized to explore its potential. • Two configurations employing two different heat exchangers are considered. • The maximum electrical efficiency is 25%, the maximum overall efficiency is 70%. • The operation in load following mode is effective for both configurations. - Abstract: The aim of this paper is to demonstrate that, thanks to recent advances in designing micro steam expanders and gas to gas heat exchangers, the use of small combined cycles for simultaneous generation of heat and power from the external combustion of solid biomass and low quality biofuels is feasible. In particular, a novel typology of combined cycle that has the potential both to be cost-effective and to achieve a high level of efficiency is presented. In the small combined cycle proposed, a commercially available micro-steam turbine is utilized as the steam expander of the bottoming cycle, while the conventional microturbine of the topping cycle is replaced by a cheaper automotive turbocharger. The feasibility, reliability and availability of the required mechanical and thermal components are thoroughly investigated. In order to explore the potential of such a novel typology of power plant, an optimization procedure, based on a genetic algorithm combined with a computing code, is utilized to analyze the trade-off between the maximization of the electrical efficiency and the maximization of the thermal efficiency. Two design optimizations are performed: the first one makes use of the innovative “Immersed Particle Heat Exchanger”, whilst a nickel alloy heat exchanger is used in the other one. After selecting the optimum combination of the design parameters, the operation in load following mode is also assessed for both configurations

  7. Process heat cogeneration using a high temperature reactor

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Gustavo, E-mail: gustavoalonso3@gmail.com [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca s/n, Ocoyoacac, Edo. De Mexico 52750 (Mexico); Instituto Politécnico Nacional, Unidad Profesional Adolfo Lopez Mateos, Ed. 9, Lindavista, D.F. 07300 (Mexico); Ramirez, Ramon [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca s/n, Ocoyoacac, Edo. De Mexico 52750 (Mexico); Valle, Edmundo del [Instituto Politécnico Nacional, Unidad Profesional Adolfo Lopez Mateos, Ed. 9, Lindavista, D.F. 07300 (Mexico); Castillo, Rogelio [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca s/n, Ocoyoacac, Edo. De Mexico 52750 (Mexico)

    2014-12-15

    Highlights: • HTR feasibility for process heat cogeneration is assessed. • A cogeneration coupling for HTR is proposed and process heat cost is evaluated. • A CCGT process heat cogeneration set up is also assessed. • Technical comparison between both sources of cogeneration is performed. • Economical competitiveness of the HTR for process heat cogeneration is analyzed. - Abstract: High temperature nuclear reactors offer the possibility to generate process heat that could be used in the oil industry, particularly in refineries for gasoline production. These technologies are still under development and none of them has shown how this can be possible and what will be the penalty in electricity generation to have this additional product and if the cost of this subproduct will be competitive with other alternatives. The current study assesses the likeliness of generating process heat from Pebble Bed Modular Reactor to be used for a refinery showing different plant balances and alternatives to produce and use that process heat. An actual practical example is presented to demonstrate the cogeneration viability using the fact that the PBMR is a modular small reactor where the cycle configuration to transport the heat of the reactor to the process plant plays an important role in the cycle efficiency and in the plant economics. The results of this study show that the PBMR would be most competitive when capital discount rates are low (5%), carbon prices are high (>30 US$/ton), and competing natural gas prices are at least 8 US$/mmBTU.

  8. INVESTIGATION OF SYSTEM EFFICIENCY OF EXPANSION OF EXISTING COGENERATING POWER PLANTS IN THE POWER SYSTEM OF MOLDOVA

    Directory of Open Access Journals (Sweden)

    Postolaty V.

    2012-08-01

    Full Text Available The paper considers the energy modes of Moldova at the introduction of new facilities at the existing heating plants. Its influence on the change in the intra-and inter-system power flows and the amount of power losses in power systems of Moldova and Ukraine in parallel operation is studied as well.

  9. Co-generation project for the Combined Cycle Power Plant President Juarez Rosarito and a reverse osmosis desalting plant; Proyecto de cogeneracion para la planta de ciclo combinado Presidente Juarez Rosarito y una planta desaladora de osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Beltran Mora, Hector; Espindola Hernandez, Salvador [Universidad NAcional Autonoma de Mexico (UNAM), Mexico, D.F. (Mexico)

    2006-11-15

    In this work a technical and economical analysis of the installation of a reverse osmosis desalting plant connected to a power station that uses the combined cycle technology under a co-generation scheme is presented: production of electricity and water. The operation program of the desalting power station will be determined by the demand of energy of the combined cycle power station; the proposal is that the desalting plant operates in the hours of low load of the power station and shuts down at the peak hours of electrical energy demand. So that this study is representative, the demand curves of electric energy of the units of combined cycle of Central President Juarez Rosarito of the Comision Federal de Electricidad (CFE) have been taken and updated the data of the reverse osmosis desalting plants that are available at the moment in the market. As basis of the study the level costs will be determined so much as the electrical energy generated by the power station of combined cycle, operating inside and outside of a co-generation scheme and the costs made level for the water produced by the reverse osmosis plant under two assumptions: the first one is buying the electrical energy from CFE and the second one considering that the CFE is the owner of the desalting plant and therefore the cost of electrical energy to desalting the plant is zero. This work shows the economic impacts on the costs of the generation of electrical energy and on those of the desalted water in a co-generation scheme. The results shown in this study can be considered for the future planning in the construction of desalting plants to supply of water in the Northwestern zones of the country where serious problems of water shortage exist. [Spanish] En este trabajo se presenta un analisis tecnico y economico de la instalacion de una planta desaladora de osmosis inversa acoplada a una central de generacion de energia electrica que utiliza la tecnologia de ciclo combinado bajo un esquema de

  10. Optimal Design of Cogeneration Systems in Industrial Plants Combined with District Heating/Cooling and Underground Thermal Energy Storage

    Directory of Open Access Journals (Sweden)

    Vincenzo Dovì

    2011-12-01

    Full Text Available Combined heat and power (CHP systems in both power stations and large plants are becoming one of the most important tools for reducing energy requirements and consequently the overall carbon footprint of fundamental industrial activities. While power stations employ topping cycles where the heat rejected from the cycle is supplied to domestic and industrial consumers, the plants that produce surplus heat can utilise bottoming cycles to generate electrical power. Traditionally the waste heat available at high temperatures was used to generate electrical power, whereas energy at lower temperatures was either released to the environment or used for commercial or domestic heating. However the introduction of new engines, such as the ones using the organic Rankine cycle, capable of employing condensing temperatures very close to the ambient temperature, has made the generation of electrical power at low temperatures also convenient. On the other hand, district heating is becoming more and more significant since it has been extended to include cooling in the warm months and underground storage of thermal energy to cope with variable demand. These developments imply that electric power generation and district heating/cooling may become alternative and not complementary solutions for waste energy of industrial plants. Therefore the overall energy management requires the introduction of an optimisation algorithm to select the best strategy. In this paper we propose an algorithm for the minimisation of a suitable cost function, for any given variable heat demand from commercial and domestic users, with respect to all independent variables, i.e., temperatures and flowrates of warm fluid streams leaving the plants and volume and nature of underground storage. The results of the preliminary process integration analysis based on pinch technology are used in this algorithm to provide bounds on the values of temperatures.

  11. Effect of sags and shorts at electric network interruptions in cogeneration industrial plants; Efecto de los huecos de tension en plantas industriales con cogeneraciones

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Cander, J.; Bonfil, C. [Iberdrola (Spain); Fuster, V.; Catalan, S.

    1995-08-01

    At he moment the number of cogeneration facilities in the east region of Spain is rapidly increasing. The results concerning the behaviour and the problems that appear with sags and short at electric network interruptions are studied. It concludes the need of the substation protection system reconsideration to avoid the negative effects produced. 4 refs.

  12. Reviving manufacturing with a federal cogeneration policy

    International Nuclear Information System (INIS)

    Brown, Marilyn A.; Cox, Matt; Baer, Paul

    2013-01-01

    Improving the energy economics of manufacturing is essential to revitalizing the industrial base of advanced economies. This paper evaluates ex-ante a federal policy option aimed at promoting industrial cogeneration—the production of heat and electricity in a single energy-efficient process. Detailed analysis using the National Energy Modeling System (NEMS) and spreadsheet calculations suggest that industrial cogeneration could meet 18% of U.S. electricity requirements by 2035, compared with its current 8.9% market share. Substituting less efficient utility-scale power plants with cogeneration systems would produce numerous economic and environmental benefits, but would also create an assortment of losers and winners. Multiple perspectives to benefit/cost analysis are therefore valuable. Our results indicate that the federal cogeneration policy would be highly favorable to manufacturers and the public sector, cutting energy bills, generating billions of dollars in electricity sales, making producers more competitive, and reducing pollution. Most traditional utilities, on the other hand, would lose revenues unless their rate recovery procedures are adjusted to prevent the loss of profits due to customer owned generation and the erosion of utility sales. From a public policy perspective, deadweight losses would be introduced by market-distorting federal incentives (ranging annually from $30 to $150 million), but these losses are much smaller than the estimated net social benefits of the federal cogeneration policy. - Highlights: ► Industrial cogeneration could meet 18% of US electricity demand by 2035, vs. 8.9% today. ► The policy would be highly favorable to manufacturers and the public. ► Traditional electric utilities would likely lose revenues. ► Deadweight loss would be introduced by tax incentives. ► The policy’s net social benefits would be much larger.

  13. Cogeneration: A marketing opportunity for pipelines

    International Nuclear Information System (INIS)

    Ulrich, J.S.

    1992-01-01

    This chapter describes the marketing of dual-purpose power plants by pipeline companies as a long term marketing strategy for natural gas. The author uses case studies to help evaluate a company's attitude toward development of a market for cogeneration facilities. The chapter focuses on strategies for developing markets in the industrial sector and identifying customer groups that are likely to respond in like manner to a marketing strategy

  14. Intraday trade is the answer for cogeneration

    International Nuclear Information System (INIS)

    Lomme, J.J.

    2006-01-01

    It is possible for operators of small cogeneration plants to sell electricity on the day-ahead market of the Amsterdam Power Exchange (APX) or through the unbalance market of the Dutch power transmission operator TenneT. However, it is difficult for them to take part in the market. The solution could be a so-called intraday-market, in which electricity trade can be a continuous process, but the question is who will start such a market [nl

  15. Fossil fuel savings, carbon emission reduction and economic attractiveness of medium-scale integrated biomass gasification combined cycle cogeneration plants

    Directory of Open Access Journals (Sweden)

    Kalina Jacek

    2012-01-01

    Full Text Available The paper theoretically investigates the system made up of fluidized bed gasifier, SGT-100 gas turbine and bottoming steam cycle. Different configurations of the combined cycle plant are examined. A comparison is made between systems with producer gas (PG and natural gas (NG fired turbine. Supplementary firing of the PG in a heat recovery steam generator is also taken into account. The performance of the gas turbine is investigated using in-house built Engineering Equation Solver model. Steam cycle is modeled using GateCycleTM simulation software. The results are compared in terms of electric energy generation efficiency, CO2 emission and fossil fuel energy savings. Finally there is performed an economic analysis of a sample project. The results show relatively good performance in the both alternative configurations at different rates of supplementary firing. Furthermore, positive values of economic indices were obtained. [Acknowledgements. This work was carried out within the frame of research project no. N N513 004036, titled: Analysis and optimization of distributed energy conversion plants integrated with gasification of biomass. The project is financed by the Polish Ministry of Science.

  16. System Statement of Tasks of Calculating and Providing the Reliability of Heating Cogeneration Plants in Power Systems

    Science.gov (United States)

    Biryuk, V. V.; Tsapkova, A. B.; Larin, E. A.; Livshiz, M. Y.; Sheludko, L. P.

    2018-01-01

    A set of mathematical models for calculating the reliability indexes of structurally complex multifunctional combined installations in heat and power supply systems was developed. Reliability of energy supply is considered as required condition for the creation and operation of heat and power supply systems. The optimal value of the power supply system coefficient F is based on an economic assessment of the consumers’ loss caused by the under-supply of electric power and additional system expences for the creation and operation of an emergency capacity reserve. Rationing of RI of the industrial heat supply is based on the use of concept of technological margin of safety of technological processes. The definition of rationed RI values of heat supply of communal consumers is based on the air temperature level iside the heated premises. The complex allows solving a number of practical tasks for providing reliability of heat supply for consumers. A probabilistic model is developed for calculating the reliability indexes of combined multipurpose heat and power plants in heat-and-power supply systems. The complex of models and calculation programs can be used to solve a wide range of specific tasks of optimization of schemes and parameters of combined heat and power plants and systems, as well as determining the efficiency of various redundance methods to ensure specified reliability of power supply.

  17. The cogeneration in France; La cogeneration en France

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Since the years 90 many measures have been decided by the government in favor of the cogeneration, to implement a juridical, fiscal, technical and economical framework. After a presentation of the three main channels and the advantages of the cogeneration, the author presents these measures. (A.L.B.)

  18. Diesel engine cogeneration plants in the context of integration of renewable energy sources in power supply; Dieselmotor-Kraft-Waerme-Kopplungsanlagen im Kontext der Integration Erneuerbarer Energien in die Energieversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Sievers, John

    2010-10-29

    The aim of this thesis is to investigate and assess future options, potentials, strengths and weaknesses of cogeneration of heat and power. This is carried out against the background of global climate change and the integration of an increasing share of fluctuating renewable energies in power generation considering the necessity of guaranteeing a reliable, efficient, sustainable and cost effective power supply. It is assumed that the transition process to an entirely renewable energy-based electricity generation in Germany will considerably depend on the integration of wind energy because of its economic competitiveness, environmental friendliness and potential. However, power generation using wind energy fluctuates quite considerably. Diesel motors are here investigated as a decentralized integration instrument. Thanks to their great flexibility, high efficiency and relatively low nominal capacity, they perfectly meet the requirements for the simultaneous decentralized use of heat. Boundary conditions of Diesel motor combined heat and power plants (CHP) are analyzed and described in this work, different models for wind energy integration are elaborated, and these models are used for several variations to simulate the balance of wind energy by cogeneration. In this context, environmental impacts are discussed. Common assessment methods on environmental impacts of CHP distort the results. The so-called output method is developed and described, by which the final assessment of environmental impacts is not implicitly mixed - as is commonly the case - with the calculation of environmental impacts. This output method is used to compare CHP generation with other energy conversion processes within the context of power generation including insulation of buildings, the use of different fuels and different applications for cogeneration. This work clearly demonstrates that while bio fuel resources can be optimally used for power generation, cogenerated electricity could also

  19. Experimental energetic analysis of gas natural-powered fuel cell cogeneration plant; Analise energetica experimental de uma planta de co-geracao com celulas a combustivel e gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Furtado, Jose G.M.; Lopes, Francisco C.; Silva Junior, Fernando R.; Soares, Guilherme F.W.; Serra, Eduardo T. [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil)

    2008-07-01

    Power systems based on fuel cells have been considered for residential and commercial applications in energy Distributed Generation (DG) market as these systems can minimize their acquisition, installation and operation high costs. In this work we present an experimental analysis of a power generation system formed by a 5 kW proton exchange membrane fuel cell unit and a natural gas reformer (fuel processor) for hydrogen production, of the CEPEL's Fuel Cell Laboratory. It was determined the electrical performance of the cogeneration system in function of the design and operational power plant parameters. Additionally, it was verified the influence of the activation conditions of the fuel cell electrocatalytic system on the system performance. It also appeared that the use of hydrogen produced from the natural gas catalytic reforming provided the system operation in excellent electrothermal stability conditions resulting in increase of the energy conversion efficiency and of the economy of the cogeneration power plant. The maximum electrical efficiency achieved was around 38% and in all power range unit operated with average potential per single fuel cell higher than 0.60 V. (author)

  20. Proceedings of the 7th cogeneration and independent power congress, natural gas purchasing '92, HVAC controls and energy conservation '92, 1992 indoor air quality congress

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This book is covered under the following topics: Cogeneration and IPP Market Developments; Natural Gas Marketing and Deliverability Strategies; Identifying the Sources of IAQ Problems; User-Owner Cogeneration Systems; Strategies for International Power Development; Strategic Fuel Purchasing; Cogeneration and utility Power Plant Compliance Issues; New HVAC Design Trends; IAQ Practical solutions: Case Studies

  1. The alarming future for cogeneration

    International Nuclear Information System (INIS)

    Koevoet, H.

    2000-01-01

    Low prices and uncertainty in pricing of energy, higher costs for investment and expensive fuels are the most important reasons why the growth of cogeneration capacity in the Netherlands stagnates. The liberalization of the energy market appears to be the malefactor. A brief overview is given of the ECN (Netherlands Energy Research Foundation) report 'Toekomst warmtekrachtkoppeling' (Future of cogeneration)

  2. Cogeneration technologies, optimisation and implementation

    CERN Document Server

    Frangopoulos, Christos A

    2017-01-01

    Cogeneration refers to the use of a power station to deliver two or more useful forms of energy, for example, to generate electricity and heat at the same time. This book provides an integrated treatment of cogeneration, including a tour of the available technologies and their features, and how these systems can be analysed and optimised.

  3. Overview of high temperature reactor activities relevant for cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    Bogusch, Edgar; Brinkmann, Gerd; Hittner, Dominique [AREVA NP GmbH, Erlangen (Germany)

    2013-07-01

    The HTR offers a great potential for cogeneration of heat and electricity to supply conventional process plants thus reducing the emission of greenhouse gases. The modular design and the flexibility to adapt to the customer's needs in terms of thermal/electrical power and temperature, in addition to its inherent safety features makes the HTR a promising candidate for cogeneration applications. The coupling to a conventional process plant has to be designed to meet the requirements of power and temperature demand, the distance between the nuclear and the conventional plant and its safety requirements. Several countries such as China, the US, Japan and Korea are investigating the use of an HTR for cogeneration. The European Commission is supporting relevant activities through funding of related projects. (orig.)

  4. Optimal planning and economic evaluation of cogeneration system

    International Nuclear Information System (INIS)

    Oh, Si-Doek; Lee, Ho-Jun; Jung, Jung-Yeul; Kwak, Ho-Young

    2007-01-01

    Cogeneration plants, which simultaneously produce electricity and heat energy, have been introduced increasingly for commercial and domestic applications in Korea because of their energy efficiency. The optimal plant configuration of a specific commercial building can be determined by selecting the sizes and the number of cogeneration systems and the auxiliary equipment based on the annual demands of electricity, heating and cooling. In this study, a mixed-integer, linear programming, utilizing the branch and bound algorithm was used to obtain the optimal solution. Both the optimal configuration system equipment and the optimal operational mode were determined based on the annual cost method for the installation of a cogeneration system to a hospital and a group of apartments in Seoul, Korea. In addition, the economic evaluation for the optimal cogeneration system depending on the fuel tariff system was calculated. A short payback period and higher internal rate of return on the initial investment were found to be essential for the adoption of cogeneration plants to hospitals and apartments

  5. Optimal planning and economic evaluation of cogeneration system

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Si-Doek; Lee, Ho-Jun [Hyosung Corporation, Bangbae B/D, 1006-2, Bangbae-Dong, Seocho-Ku, Seoul 137-850 (Korea); Jung, Jung-Yeul; Kwak, Ho-Young [Mechanical Engineering Department, Chung-Ang University, 221, Huksuk-Dong, Dongjak-Gu, Seoul 156-756 (Korea)

    2007-05-15

    Cogeneration plants, which simultaneously produce electricity and heat energy, have been introduced increasingly for commercial and domestic applications in Korea because of their energy efficiency. The optimal plant configuration of a specific commercial building can be determined by selecting the sizes and the number of cogeneration systems and the auxiliary equipment based on the annual demands of electricity, heating and cooling. In this study, a mixed-integer, linear programming, utilizing the branch and bound algorithm was used to obtain the optimal solution. Both the optimal configuration system equipment and the optimal operational mode were determined based on the annual cost method for the installation of a cogeneration system to a hospital and a group of apartments in Seoul, Korea. In addition, the economic evaluation for the optimal cogeneration system depending on the fuel tariff system was calculated. A short payback period and higher internal rate of return on the initial investment were found to be essential for the adoption of cogeneration plants to hospitals and apartments. (author)

  6. Conventional and cogeneration costs

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Two areas must be addressed in the preparation of any feasibility analysis. First is the identification of all cost components, and second is the development of actual cost estimates. In this chapter, the individual cost components are identified and reviewed. Each of them should be considered in the conduct of any feasibility study, for it is the depth to which they are analyzed that is the most significant contributor to the cost of the analysis. The discussion reviews both the operating and the capital cost considerations of cogeneration economics

  7. Micro cogeneration in residential scale; Bancada de sistema de cogeracao de pequeno porte

    Energy Technology Data Exchange (ETDEWEB)

    Dutra, Jose Carlos Charamba; Primo, Ana Rosa Mendes; Magnani, Fabio Santana; Henriquez, Jorge R. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Moura, Newton Reis de; Campos, Michel Fabianski [PETROBRAS, Rio de Janeiro, RJ (Brazil); Zimmerle, Sergio Ricardo T.S. [Companhia Pernambucana de Gas (COPERGAS), Recife, PE (Brazil)

    2004-07-01

    Cogeneration is very important to spread the use of natural gas in Brazil. Most of the existing cogeneration plants are of considerable size, as used in industries or commercial centers. Places with low demand on electrical or thermal energy (e.g. small industries, blocs of houses, etc.) could also benefit of cogeneration, but there is no available data about micro-cogeneration in Brazil. In order to verify the technical and economical viability of small size systems of cogeneration, FINEP/PETROBRAS/COPERGAS financed a project of micro-cogeneration at the Federal University of Pernambuco (UFPE), involving experiments on a micro turbine and a generator group, both with 30 kW power. The laboratory is also composed by two heat exchangers to regenerate the heat from the micro-turbine and generator group, a single effect absorption chiller, with 10 TR capacity, two thermal storage tanks (for hot and cold water) and a compression split of 5 TR. Data to build performance curves of the equipment will be stored and analyzed, in order to build their performance curves, allowing the overall cogeneration efficiency to be found. Most probable situations of thermal and electric power demands will be simulated. The aim of the simulations is to achieve the optimal situation for micro-cogeneration, which will offer the best efficiency, the lowest cost for buying the equipment and the lowest operational cost. A software was also developed, which optimizes micro-cogeneration systems. (author)

  8. Evaluation of diurnal thermal energy storage combined with cogeneration systems

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaram, S.; Brown, D.R.; Drost, M.K.

    1992-11-01

    This report describes the results of an evaluation of thermal energy storage (TES) integrated with simple gas turbine cogeneration systems. The TES system captures and stores thermal energy from the gas turbine exhaust for immediate or future generation of process heat. Integrating thermal energy storage with conventional cogeneration equipment increases the initial cost of the combined system; but, by decoupling electric power and process heat production, the system offers the following two significant advantages: (1) Electric power can be generated on demand, irrespective of the process heat load profile, thus increasing the value of the power produced; (2) Although supplementary firing could be used to serve independently varying electric and process heat loads, this approach is inefficient. Integrating TES with cogeneration can serve the two independent loads while firing all fuel in the gas turbine. The study evaluated the cost of power produced by cogeneration and cogeneration/TES systems designed to serve a fixed process steam load. The value of the process steam was set at the levelized cost estimated for the steam from a conventional stand-alone boiler. Power costs for combustion turbine and combined-cycle power plants were also calculated for comparison. The results indicated that peak power production costs for the cogeneration/TES systems were between 25% and 40% lower than peak power costs estimated for a combustion turbine and between 15% and 35% lower than peak power costs estimated for a combined-cycle plant. The ranges reflect differences in the daily power production schedule and process steam pressure/temperature assumptions for the cases evaluated. Further cost reductions may result from optimization of current cogeneration/TES system designs and improvement in TES technology through future research and development.

  9. Evaluation of diurnal thermal energy storage combined with cogeneration systems

    Science.gov (United States)

    Somasundaram, S.; Brown, D. R.; Drost, M. K.

    1992-11-01

    This report describes the results of an evaluation of thermal energy storage (TES) integrated with simple gas turbine cogeneration systems. The TES system captures and stores thermal energy from the gas turbine exhaust for immediate or future generation of process heat. Integrating thermal energy storage with conventional cogeneration equipment increases the initial cost of the combined system; but, by decoupling electric power and process heat production, the system offers the following significant advantages: (1) electric power can be generated on demand, irrespective of the process heat load profile, thus increasing the value of the power produced; (2) although supplementary firing could be used to serve independently varying electric and process heat loads, this approach is inefficient. Integrating TES with cogeneration can serve the two independent loads while firing all fuel in the gas turbine. The study evaluated the cost of power produced by cogeneration and cogeneration/TES systems designed to serve a fixed process steam load. The value of the process steam was set at the levelized cost estimated for the steam from a conventional stand-alone boiler. Power costs for combustion turbine and combined-cycle power plants were also calculated for comparison. The results indicated that peak power production costs for the cogeneration/TES systems were between 25 and 40 percent lower than peak power costs estimated for a combustion turbine and between 15 and 35 percent lower than peak power costs estimated for a combined-cycle plant. The ranges reflect differences in the daily power production schedule and process steam pressure/temperature assumptions for the cases evaluated. Further cost reductions may result from optimization of current cogeneration/TES system designs and improvement in TES technology through future research and development.

  10. Incentives for cogeneration in Italy: Logic and implementation

    International Nuclear Information System (INIS)

    Tomassetti, G.

    1992-01-01

    Within the framework of legal and financial incentives made possible through Italian legislation on cogeneration plants for on-site power generation, this paper reviews the planning criteria that went into the formulation of the incentives and the response obtained from small, medium and large industrial firms. The discussion takes into account the following aspects: the optimal timing of retrofits, national energy conservation and environmental policy objectives, energy surcharges, benefits to consumers as compared with those for energy producers, benefits from incentives as a function of cogeneration plant size, and the technical complexity of application requirements for prospective applicants

  11. Gas turbine modular helium reactor in cogeneration

    International Nuclear Information System (INIS)

    Leon de los Santos, G.

    2009-10-01

    This work carries out the thermal evaluation from the conversion of nuclear energy to electric power and process heat, through to implement an outline gas turbine modular helium reactor in cogeneration. Modeling and simulating with software Thermo flex of Thermo flow the performance parameters, based on a nuclear power plant constituted by an helium cooled reactor and helium gas turbine with three compression stages, two of inter cooling and one regeneration stage; more four heat recovery process, generating two pressure levels of overheat vapor, a pressure level of saturated vapor and one of hot water, with energetic characteristics to be able to give supply to a very wide gamma of industrial processes. Obtaining a relationship heat electricity of 0.52 and efficiency of net cogeneration of 54.28%, 70.2 MW net electric, 36.6 MW net thermal with 35% of condensed return to 30 C; for a supplied power by reactor of 196.7 MW; and with conditions in advanced gas turbine of 850 C and 7.06 Mpa, assembly in a shaft, inter cooling and heat recovery in cogeneration. (Author)

  12. Implementation of energy efficiency programs using cogeneration based on internal combustion engines

    Directory of Open Access Journals (Sweden)

    Minciuc Eduard

    2017-07-01

    Full Text Available The paper presents an analysis of implementation of CHP plants based on internal combustion engines at different industrial companies. The authors have presented general aspects regarding utilization of internal combustion engines for cogeneration. There have been presented different possibilities of classification of internal combustion engines. Further on authors have presented different possibilities for increasing the efficiency of internal combustion engines, including: supercharging compression ratio increase, advanced heat recuperation for combined production of heat and power. There have also been presented different measures for increasing energy efficiency on site, including measures for CHP plant and internal combustion engines and measures for other auxiliary equipment and measures for technological equipment. In the second part of the paper authors have presented three case studies of utilization of internal combustion engines at a cogeneration plant for different industrial companies: cogeneration plant at a company from pharmaceutical sector, cogeneration plant at a beer production company and cogeneration plant at a company of electrical insulation materials. The results of the analysis led to following conclusions: implementation of cogeneration solutions based on internal combustion engines lead to significant financial savings, implementation of cogeneration solutions based on internal combustion engines can also lead to reducing environmental impact, it ensures higher global energy production efficiency and higher power efficiency compared to National Power System and to separate power and heat generation, it can lead to increased safety in energy supply of the company, it can also increase the reliability of power supply in cases of National Power Grid faults.

  13. High-temperature gas-cooled reactor steam cycle/cogeneration application study update

    International Nuclear Information System (INIS)

    1981-09-01

    Since publication of a report on the application of a High Temperature Gas-Cooled Reactor Steam Cycle/Cogeneration (HTGR-SC/C) plant in December of 1980, progress has continued on application related activities. In particular, a reference plant and an application identification effort has been performed, a variable cogeneration cycle balance-of-plant design was developed and an updated economic analysis was prepared. A reference HTGR-SC/C plant size of 2240 MW(t) was selected, primarily on the basis of 2240 MW(t) being in the mid-range of anticipated application needs and the availability of the design data from the 2240 MW(t) Steam Cycle/Electric generation plant design. A variable cogeneration cycle plant design was developed having the capability of operating at a range of process steam loads between the reference design load (full cogeneration) and the no process steam load condition

  14. DDACE cogeneration systems : 10 case studies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    DDACE Power Systems are experts in green energy power generation and provide solutions that deal with waste and industrial by-products. The company develops practical energy solutions that address environmental and financial concerns facing both industrial and municipal customers. The following 10 case studies are examples of the installations that DDACE Power Systems have completed in recent years: (1) a combined heat and emergency power installation on the roof of a 19 storey apartment building on Bloor Street in Toronto, Ontario. The cogeneration package provides electricity and heat to the entire building, replacing an old diesel generator, (2) a combined heat and emergency power installation at the Villa Colombo extended care facility in Vaughan, Ontario. The cogeneration system provides heat and power to the building, as well as emergency power, (3) emergency standby power with demand response capabilities at Sobeys Distribution Warehouse in Vaughan, Ontario. The primary purpose of the 2.4 MW low emission, natural gas fuelled emergency standby generator is to provide emergency power to the building in the event of a grid failure, (4) a dual fuel combined heat and power installation at the Queensway Carleton Hospital in Ottawa, Ontario that provides electricity, hot water and steam to all areas of the hospital, (5) a tri-generation installation at the Ontario Police College in Aylmer, Ontario which provides power and heat to the building as well as emergency power in the event of a grid failure. An absorption chiller provides cooling in the summer and an exhaust emission control system reduces NOx emissions, (6) a biomass gasification installation at Nexterra Energy in Kamloops, British Columbia. The 239 kW generator is fueled by synthesis gas, (7) biogas utilization at Fepro Farms in Cobden, Ontario for treatment of the facility's waste products. The biogas plant uses cow manure, as well as fats, oil and grease from restaurants to produce electricity and

  15. The Optimal Operation Criteria for a Gas Turbine Cogeneration System

    Directory of Open Access Journals (Sweden)

    Atsushi Akisawa

    2009-04-01

    Full Text Available The study demonstrated the optimal operation criteria of a gas turbine cogeneration system based on the analytical solution of a linear programming model. The optimal operation criteria gave the combination of equipment to supply electricity and steam with the minimum energy cost using the energy prices and the performance of equipment. By the comparison with a detailed optimization result of an existing cogeneration plant, it was shown that the optimal operation criteria successfully provided a direction for the system operation under the condition where the electric power output of the gas turbine was less than the capacity

  16. Cogeneration of electricity from biomass in India

    International Nuclear Information System (INIS)

    Bhargava, H.

    1997-01-01

    India, which is the largest sugarcane producer in the world and which has chronic severe power deficits, has excellent business opportunities in over 400 sugar mills for cogeneration of exportable electrical energy from bagasse. The current potential is between 2,500 and 3,000 MW of capacity. Individual plant size will range from 10 to 80 MW. The opportunities take the form of turnkey projects for promoter sugar mills, as well as for setting up facilities on BOOT (Build, Own, Operate and Transfer), BOO (Build, Own and Operate) or BOLT (Build, Own, Lease and Transfer) concepts. (author)

  17. Benefit Analysis of Emergency Standby System Promoted to Cogeneration System

    Directory of Open Access Journals (Sweden)

    Shyi-Wen Wang

    2016-07-01

    Full Text Available Benefit analysis of emergency standby system combined with absorption chiller promoted to cogeneration system is introduced. Economic evaluations of such upgraded projects play a major part in the decisions made by investors. Time-of-use rate structure, fuel cost and system constraints are taken into account in the evaluation. Therefore, the problem is formulated as a mixed-integer programming problem. Using two-stage methodology and modified mixed-integer programming technique, a novel algorithm is developed and introduced here to solve the nonlinear optimization problem. The net present value (NPV method is used to evaluate the annual benefits and years of payback for the cogeneration system. The results indicate that upgrading standby generators to cogeneration systems is profitable and should be encouraged, especially for those utilities with insufficient spinning reserves, and moreover, for those having difficulty constructing new power plants.

  18. About the gasification of untreated scrap and waste wood in fluidized bed reactor for use in decentralized gas engine-cogeneration plants; Zur Vergasung von Rest- und Abfallholz in Wirbelschichtreaktoren fuer dezentrale Energieversorgungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Tepper, H.

    2005-10-20

    This dissertation examines the thermochemical conversion (gasification) of untreated scrap and waste wood in combustible gases for use in decentralized gas engine-cogeneration plants of low output (1 to 10 MW fuel power). A general section goes into the basics of the energetic utilization of solid biomass, the subprocesses of thermochemical conversion being described in more detail. Special attention is given to the processes and state of the art of biomass gasification in decentralized plants. A theoretical section analyzes the gasification models for solid biomass presented in the literature. Based on this analysis, a simplified kinetic model is derived for the gasification of untreated scrap and waste wood with air in bubbling fluidized bed reactors. It includes a fluid mechanic analysis of the fluidized bed based on HILLIGARDT, an empirical pyrolysis model and a global kinetic approach to the main chemical reaction taken from the literature. An experimental section describes the tests of the gasification of forest scrap wood in a semi-industrial fluidized bed gasification test plant with 150 kW fuel power and presents the significant test results. The gasification model derived is applied to check the test plant's standard settings and compare them with measured values. Furthermore, the model is employed to explain basic reaction paths and zones and to perform concluding parameter simulations. (orig.)

  19. Cogeneration opportunities in the maritime provinces

    International Nuclear Information System (INIS)

    MacPherson, S.W.

    1999-01-01

    With the arrival of natural gas in New Brunswick in November 1999, the province will be faced with new power generation development opportunities in four different categories of power projects. These include industrial self generation (including cogeneration), merchant power plants, power projects to replace aging facilities, and power projects to help meet future environmental needs. New Brunswick's competitive advantage in harnessing the power generation development opportunities lies in the fact that it is close to major electricity markets in Quebec and New England. It also has many available generation sites. The province's many pulp and paper plants with large process steam needs are also ideal candidates for cogeneration. Some of the major competitive advantages of natural gas over coal are its lower operation and maintenance costs, it is thermally more efficient, produces lower emissions to the environment and prices are competitive. One of the suggestions in New Brunswick Power's new restructuring proposal is to unbundle electricity service in the province into generation and transmission and distribution services. Three gas-fired projects have already been proposed for the province. The 284 MW Bayside Power Project at the Courtenay Bay Generating Station is the most advanced

  20. Stepping on the gas for district heating in Germany. Gas and steam turbines for cogeneration; Gas geben fuer Fernwaerme in Deutschland. Gas- und Dampfturbinen fuer die KWK

    Energy Technology Data Exchange (ETDEWEB)

    Bohtz, Christian [Alstom Power, Baden (Switzerland). Marketing and Product Management Gas Business

    2011-07-15

    Measured by its intensive efforts to lower CO{sub 2} emissions Germany is one of the leading countries in the EU. One contribution to this end is to be had from cogeneration. As a provider of cogeneration plants Alstom is working to improve the fuel efficiency as well as the overall efficiency and flexibility of its products. The author explains the technology of gas-fired cogeneration plants and gives three examples of their use.

  1. Mini/micro cogeneration, basis for installation. Dimensioning, accounting and potential. Project report 1; Mini/mikrokraftvarme, forudsaetninger for installation. Dimensionering, afregningsforhold og potentiale. Projektrapport 1

    Energy Technology Data Exchange (ETDEWEB)

    Wit, J. de; Iskov, H.

    2005-11-15

    Cogeneration is quite spread in Denmark. Approx. 50 % of the power supply and 80 % of the district heating supply come from cogeneration. Combined heat and power is produced on both centralized (large) plants and decentralized plants. Decentralized combined heat and power plants (typically based on natural gas) use gas motors or gas turbines for power and heat production. Cogeneration of heat and power saves primary fuels and a directly derived effect from cogeneration is CO{sub 2} emission reduction. If fuels with higher specific CO{sub 2} emission than natural gas (e.g. coal, oil) are substituted, additional CO{sub 2} reduction can be reached. (BA)

  2. Cogeneration for small SAGD projects

    Energy Technology Data Exchange (ETDEWEB)

    Albion, Stuart [AMEC BDR Limited (United Kingdom)

    2011-07-01

    As many SAGD projects are being developed in remote locations, the supply of a steady source of power to them becomes an important question. Connecting these remote facilities to a grid can often be difficult and costly. This presentation, by AMEC BDR Limited, promotes the use of cogeneration in small SAGD projects. Cogeneration is the generation of two forms of energy from one fuel source. In this particular case, the energy forms would be electricity and heat. In many SAGD projects, a gas turbine system is used to generate the electricity, while a heat recovery system is utilized to generate steam. The use of cogeneration systems in SAGD projects, as opposed to using separate heat and electricity systems, has the potential to significantly reduce the amount of energy lost, the amount of emissions and power costs, in addition to ensuring that there is a reliable supply of steam and electricity.

  3. Experiences Applying Cogeneration Policies in Europe

    International Nuclear Information System (INIS)

    Marin Nortes, M.

    1997-01-01

    This paper starts by giving overview of the development of cogeneration in the European Union. The percentage of electricity produced by cogeneration is about 10%. The difference among the countries are however very big, ranging from 40% in Denmark to 2% in France. This is because the development of cogeneration in a country depends on a number of different factors. Political and regulatory factors are of a major importance. This paper tries to show this and to examinate a number of cogeneration policies in some countries in Europe. In each case, the reasons why or why not cogeneration has been successful will be analysed. (author)

  4. First and second law analysis of diesel engine powered cogeneration systems

    International Nuclear Information System (INIS)

    Abusoglu, Aysegul; Kanoglu, Mehmet

    2008-01-01

    In this article, the thermodynamic analysis of the existing diesel engine cogeneration system is performed. All necessary data are obtained from the actual diesel engine cogeneration plant located at Gaziantep, Turkey. The exergy analysis is aimed to evaluate the exergy destruction in each component as well as the exergetic efficiencies. The thermodynamic performance of a 25.32 MW electricity and 8.1 tons/h steam capacity diesel engine cogeneration system at full load conditions is analyzed. The thermal efficiency of the overall plant is found to be 44.2% and the exergetic efficiency is 40.7%. The exergy balance equations developed in this paper may also be utilized in the exergoeconomic analysis to estimate the production costs depending on various input costs in a diesel cogeneration system

  5. Cogeneration: A new opportunity for energy production market

    International Nuclear Information System (INIS)

    Minghetti, E.

    1997-03-01

    Cogeneration or Combined Heat and Power (CHP) is an advantageous technique based on the simultaneous utilisation of electricity and heat produced. For this purpose existing energetic technologies are used. Cogeneration is based on the thermodynamics principle that producing electricity by combustion process means, at the same time, producing waste heat that can be useful utilised. Three main advantages can be lay out in a cogeneration plant: 1. High efficiency (the global efficiency is often around 80-90%). 2. Economic profit (pay back time is usually not longer than 2-4 years). 3. Low pollutant emissions (as a consequence of the high efficiency less fuel is burned for generating the same quantity of electricity). In this report are analysed various aspects of cogeneration (technical and economical) and the conditions influencing is development. Some figures on the european and national situation are also given. Finally are presented the research and development activities carried out by Italian National Agency for new Technology Energy and the Environment Energy Department to improve the efficiency and the competitiveness of this technology

  6. Micro cogeneration - rich-methane gasifier and micro gas turbine

    Directory of Open Access Journals (Sweden)

    Król Danuta

    2017-01-01

    Full Text Available The study presents a concept of integration a gasifier system with distributed generation of electricity and heat cogeneration system based on a gas microturbine. The gas generator is supplied by the RDF fuel from waste and biomass fuel Bio-CONOx. In the scale considered, the cogeneration system is designed to produce 30kWe of electricity and approx. 50kW of heat. Important perspective directions of technology development are: (i the possibility of gas microturbine to cooperate with the gasifier (up to date, in such systems were used, and continue to apply only piston engines, (ii the production of syngas in the gasifier (for efficient cogeneration in the composition of which there is a high content of methane (CH4 = 18%-22%. In the first step of possible commercialization a mathematical model to simulate single shaft gas turbine cogeneration plant has been developed. In conceptual design is application of microturbine as the prime mover of Combined Heat and Power (CHP system but with especial emphasis on possible use of a low calorific gas attainable from presented in details a gasifier unit. To support the calculations for preliminary design analysis, a computer program is developed in EES software environment.

  7. Cogeneration and the regulatory framework of energy law; Kraft-Waerme-Kopplung und der energiewirtschaftliche Ordnungsrahmen

    Energy Technology Data Exchange (ETDEWEB)

    Cornehl, Angelika Bettina

    2009-06-15

    The present publication shows that the existing regulatory framework poses numerous impediments to cogeneration plants. This holds especially for industrial operators, but also for municipalities. It has prevented cogeneration from developing its full potential both as an element of competition and as a relief for the environment. Unlike industrial cogeneration plants, those serving the public energy supply at least enjoy the privilege of regional monopoly rights. In today's liberalised electricity market, however, this can be a burden for existing municipal plants which were installed under territorial protection and in many cases have incurred high cost levels and become inflexible and lacking in entrepreneurial spirit as a result. On account of its tendency to promote optimal resource input and efficiency, competition promises positive impulses for the use of cogeneration in small-scale heat grids, where high fuel efficiency matters more. A reform of the competition regime in the power economy would eliminate numerous impediments, particularly for industrial cogeneration operators. Good hopes for the future of cogeneration in a liberalised electricity and gas market are also nurtured by cooperative supply concepts and, within the large domain of services, opportunities held out by special contracting offers.

  8. An economic analysis of small-scale cogeneration using forest biomass and sawmill residuals in northern Ontario

    International Nuclear Information System (INIS)

    Beke, N.L.

    1994-01-01

    The economic feasibility of using biomass for cogeneration in northern Ontario was investigated and the institutional factors that may affect establishment and operation of cogeneration facilities were determined. Two fuel sources for a cogeneration plant were evaluated: forest materials and sawmill residuals. To establish and operate a cogeneration plant, the policies of the Ontario Ministry of Natural Resources and Ontario Hydro needed to be analyzed. Some of the benefits of using sawmill residuals for cogeneration were identified and an inventory of sawmill residuals was compiled. The welfare effects of three pricing schemes for non-utility generated electricity are described using a neoclassical welfare model. This model is further extended to include the effects of subsidizing public utilities and using biomass to generate electricity. A competitive market for electricity generation and relating pricing structure was also examined. The results of the capital budget for the cogeneration facility indicated that by using sawmill residuals and chipped forest biomass as fuel for cogeneration, internal rates of return would be 22.7% and 8.7% and net present values would be $8,659,870 and $1,867,822, respectively. This implied that using sawmill residuals for cogeneration fuel would be both profitable and would help to reduce possible harmful effects that current dumping practices may have on the surrounding ecosystem. 84 refs., 17 figs., 14 tabs

  9. The performance of residential micro-cogeneration coupled with thermal and electrical storage

    Science.gov (United States)

    Kopf, John

    Over 80% of residential secondary energy consumption in Canada and Ontario is used for space and water heating. The peak electricity demands resulting from residential energy consumption increase the reliance on fossil-fuel generation stations. Distributed energy resources can help to decrease the reliance on central generation stations. Presently, distributed energy resources such as solar photovoltaic, wind and bio-mass generation are subsidized in Ontario. Micro-cogeneration is an emerging technology that can be implemented as a distributed energy resource within residential or commercial buildings. Micro-cogeneration has the potential to reduce a building's energy consumption by simultaneously generating thermal and electrical power on-site. The coupling of a micro-cogeneration device with electrical storage can improve the system's ability to reduce peak electricity demands. The performance potential of micro-cogeneration devices has yet to be fully realized. This research addresses the performance of a residential micro-cogeneration device and it's ability to meet peak occupant electrical loads when coupled with electrical storage. An integrated building energy model was developed of a residential micro-cogeneration system: the house, the micro-cogeneration device, all balance of plant and space heating components, a thermal storage device, an electrical storage device, as well as the occupant electrical and hot water demands. This model simulated the performance of a micro-cogeneration device coupled to an electrical storage system within a Canadian household. A customized controller was created in ESP-r to examine the impact of various system control strategies. The economic performance of the system was assessed from the perspective of a local energy distribution company and an end-user under hypothetical electricity export purchase price scenarios. It was found that with certain control strategies the micro-cogeneration system was able to improve the

  10. On-site co-generation: cost savings in view

    Energy Technology Data Exchange (ETDEWEB)

    Granson, E.

    2004-03-31

    The technical and economic aspects of cogeneration are explained with examples from Alberta and British Columbia. One of the examples is the cogeneration of steam and electricity at the ATCO/EPCOR/NOVA power plant in Joffre, Alberta, which generates enough electricity, steam and heat to supply the whole ethylene and polyethylene plant; it also boosts the provincial grid by four per cent. Another good example cited is TransCanada Pipelines' Carseland, Alberta, operation, which generates 80 MW of electricity, along with about 120 tonnes/hr of steam for Agrium's adjacent Carseland Nitrogen Operation. The electricity is generated by two GE LM6000 PD combustion turbines using natural gas as fuel. Each turbine is equipped with a Heat Recovery Steam Generator (HRSG), which captures the gas turbine exhaust heat to raise steam. The high pressure, superheated steam is sent to the Agrium facility for use by the company's nitrogen operation. Dow Chemical Canada Inc also has a power and utilities combined-cycle cogeneration plant at its Fort Saskatchewan site. By utilizing a steam turbine down the line, Dow Chemicals' Fort Saskatchewan operations are able to achieve at least an 80 per cent thermal efficiency rating for the overall process, or about a 10 to 20 per cent gain on alternate designs. The Dow Canada plant operates three GE gas turbines and two steam turbines for a total rated capacity of 300 MW of power. Cogeneration is not limited to turbines fuelled by natural gas; pulp and paper mills throughout Western Canada use wood residue as fuel to produce steam and the hot water required by the mills. Methane gas is another source of fuel being put to use in the Vancouver Landfill Cogeneration Facility at Delta, BC, which, using three Caterpillar 3532 engines, generates 5.6 MW of electricity and 6.7 MW of thermal energy. The electricity is sold to BC Hydro, while the thermal energy is used by the CanAgro greenhouses. In addition to the substantial

  11. Fort Hood solar cogeneration facility conceptual design study

    Energy Technology Data Exchange (ETDEWEB)

    1981-05-01

    A study is done on the application of a tower-focus solar cogeneration facility at the US Fort Hood Army Base in Killeen, Texas. Solar-heated molten salt is to provide the steam for electricity and for room heating, room cooling, and domestic hot water. The proposed solar cogeneration system is expected to save the equivalent of approximately 10,500 barrels of fuel oil per year and to involve low development risks. The site and existing plant are described, including the climate and plant performance. The selection of the site-specific configuration is discussed, including: candidate system configurations; technology assessments, including risk assessments of system development, receiver fluids, and receiver configurations; system sizing; and the results of trade studies leading to the selection of the preferred system configuration. (LEW)

  12. Comparative economic evaluation of environmental impact of different cogeneration technologies

    International Nuclear Information System (INIS)

    Patrascu, Roxana; Athanasovici, Victor; Raducanu, Cristian; Minciuc, Eduard; Bitir-Istrate, Ioan

    2004-01-01

    Cogeneration is one of the most powerful technologies for reduction of environmental pollution along with renewable energies. At the Kyoto Conference cogeneration has been identified as being the most important measure for reducing emissions of greenhouse effect gases. It has also been mentioned that cogeneration has a potential of reducing pollution with about 180 million tones per year. In order to promote new cogeneration technologies and evaluate the existing ones it is necessary to know and to be able to quantify in economical terms the environmental issues. When comparing different cogeneration technologies: steam turbine (TA), gas turbine (TG), internal combustion engine (MT), in order to choose the best one, the final decision implies an economic factor, which is even more important if it includes the environmental issues. The environmental impact of different cogeneration technologies is quantified using different criteria: depletion of non-renewable natural resources, eutrofisation, greenhouse effect, acidification etc. Environmental analysis using these criteria can be made using the 'impact with impact' methodology or the global one. The results of such an analysis cannot be quantified economically directly. Therefore there is a need of internalisation of ecological effects within the costs of produced energy: electricity and heat. In the energy production sector the externalizations represent the indirect effects on the environment. They can be materialised within different types of environmental impact: - Different buildings of mines, power plants etc; - Fuel losses during transportation and processing; - Effect of emissions in the air, water and soil. Introduction of the environmental impact costs in the energy price is called internalisation and it can be made using the direct and indirect methods. The paper discusses aspects regarding the emissions of cogeneration systems, the eco-taxes - method of 'internalisation' of environmental

  13. The Qualification of Electricity Production in High Efficiency Cogeneration for the Access to the Support Scheme through Green Certificates

    Directory of Open Access Journals (Sweden)

    Atanasoae P.

    2017-12-01

    Full Text Available The promotion of high efficiency cogeneration is a priority of the European Union, given the potential benefits of cogeneration relating to primary energy savings, avoiding network losses and reducing emissions of greenhouse gases. The paper presents the manner of determining the amount of electricity generated in high efficiency cogeneration for access to the support scheme through green certificates. The support scheme for the promotion of cogeneration is based on useful heat demand and primary energy savings compared with separate production of electricity and heat. We examine a cogeneration heat and power plant with ORC technology and biomass fuel, which have the technical characteristics in the nominal conditions of 1.3 MWe (electrical power and 5.4 MWth (thermal power. We also propose an algorithm for determining the useful heat, who takes into account the operational requirements of the analysed CHP unit.

  14. Process integration methodology for natural gas-fueled heat pumps and cogeneration systems

    Science.gov (United States)

    Rossiter, Alan P.

    1988-11-01

    A process integration methodology was developed for analyzing industrial processes, identifying those that will benefit from natural gas fueled heat pumps and cogeneration system as well as novel, process-specific opportunities for further equipment improvements, including performance targets. The development included the writing of software to assist in implementing the methodology and application of the procedures in studies using both literature data and plant operating data. These highlighted potential applications for gas fueled heat pumps in ethylene processes and liquor distilling plants, and slightly less attractive opportunities in a number of other plants. Many of the processes studied showed excellent potentials for cogeneration applications.

  15. Follow-up of availability for cogeneration- and heating plants - a joint platform of experiences; Uppfoeljning av tillgaenglighet inom vaerme- och kraftvaermeverk - en branschgemensam plattform av erfarenheter

    Energy Technology Data Exchange (ETDEWEB)

    Hedberg, Mats; Sfiris, George [Vattenfall Utveckling AB, Stockholm (Sweden); Andersson, Sven-Olof; Pettersson, Lasse [Vattenfall Energisystem AB, Stockholm (Sweden)

    2000-01-01

    The report before is a co-operation between Vattenfall Utveckling AB and Vattenfall Energisystem AB. Together with five biomass fueled heat plants or combined heat and power plants a database of operating experience from the operating seasons 1997-98 was built up. The plants that have contributed to the project are Haesselby Kraftvaermeverk, Naessjoe Kraftvaermeverk, Motala Vaermeverk, Kraftvaermeverket Heden 2 in Karlstad and Flintraennans Fjaerrvaermecentral in Malmoe. Even though all plants are biomass fueled, they still represent different techniques and sizes. With support of the data program TGU (Till Gaenglighets Uppfoeljning = Availability Follow-up) all faults that have an effect on the availability performance are registered by the staff on each plant. The data has been sent to Vattenfall where all fault events have been translated from the locally used terms to a common system standard according to the German KKS (Kraftwerk-Kennenzeichensystem). The data has been entered into a joint Microsoft Access database where all fault events from all plants can be saved and compared. The database also presents various search and report possibilities. The overall goal with this project was to create a platform to be able to structurally analyze unavailability and thereby on the long run increase the profitability for the owners of the plants. Even if the contents of the database still not are sufficient to draw any general conclusions from, the goals have been met. In spite of the fact that there have been problems in the course of the project, a functioning working routine has been prepared. If more plants will join in the second stage of the project, surely more valuable experiences will be brought back to the owners of the plants. The report period include all 1997 and 1998 (for Flintraennan and Motala only 1998). The observation period was 51,312 hours counted as calendar time, excluding revision periods. During that time a total of 201 faults have occurred

  16. Thermoeconomic analysis of electricity cogeneration of sugarcane origin

    International Nuclear Information System (INIS)

    Coelho, S.T.; Oliveira, S.J.R. de; Zylbersztajn, D.

    1997-01-01

    Most Brazilian sugar/alcohol industries are energy self-sufficient and, in the State of Sao Paulo, some of them even export electricity surplus to local utilities. However, despite the huge potential of electricity surplus to be generated, there are still difficulties to be solved. One of the main problems is the sale price of electricity. Despite the advantages of sugarcane-origin electricity both for the electric sector and alcohol industries, they do not agree about the sale price and most industries are not interested in selling electricity, considering the price offered by local utilities too low. This paper evaluates the cost of the electricity surplus for real plants, using thermoeconomic analysis. Different cogeneration systems are considered and the corresponding electricity costs are evaluated and compared to the current electricity marginal cost of Southeast Brazil. From obtained results, mechanisms are proposed to improve the existing cogeneration program, aiming to accomplish its initial objectives. (author)

  17. Exergoeconomic analysis of small-scale biomass steam cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Sotomonte, Cesar Adolfo; Lora, Electo Eduardo Silva [Universidade Federal de Itajuba, MG (Brazil)], e-mails: c.rodriguez32@unifei.edu.br, electo@unifei.edu.br; Venturini, Osvaldo Jose; Escobar, Jose Carlos [Universidad Federal de Itajuba, MG (Brazil)], e-mail: osvaldo@unifei.edu.br

    2010-07-01

    The principal objective of this work is to develop a calculation process, based on the second law of thermodynamics, for evaluating the thermoeconomic potential of a small steam cogeneration plant using waste from pulp processing and/or sawmills as fuel. Four different configurations are presented and assessed. The exergetic efficiency of the cycles that use condensing turbines is found to be around 11%, which has almost 3 percent higher efficiency than cycles with back pressure turbines. The thermoeconomic equations used in this paper estimated the production costs varying the fuel price. The main results show that present cost of technologies in a small-scale steam cycle cogeneration do not justify the implementation of more efficient systems for biomass prices less than 100 R$/t. (author)

  18. Performance optimization of a gas turbine-based cogeneration system

    Science.gov (United States)

    Yilmaz, Tamer

    2006-06-01

    In this paper an exergy optimization has been carried out for a cogeneration plant consisting of a gas turbine, which is operated in a Brayton cycle, and a heat recovery steam generator (HRSG). In the analysis, objective functions of the total produced exergy and exergy efficiency have been defined as functions of the design parameters of the gas turbine and the HRSG. An equivalent temperature is defined as a new approach to model the exergy rate of heat transfer from the HRSG. The optimum design parameters of the cogeneration cycle at maximum exergy are determined and the effects of these parameters on exergetic performance are investigated. Some practical mathematical relations are also derived to find the optimum values of the adiabatic temperature ratio for given extreme temperatures and consumer temperature.

  19. Analysis of cogeneration in the present energy framework

    International Nuclear Information System (INIS)

    Conde Lazaro, E.; Ramos Millan, A.; Reina Peral, P.

    2006-01-01

    In this paper, a general vision of cogeneration penetration in the European Union is shown; after this, a case study is included, evaluating as a function of two factors (electricity and emission allowance prices) the suitability of installing, for an industry with a determined thermal demand, two different options. The first one is a gas turbine cogeneration plant generating steam through a heat recovery steam generator (HRSG). The second one consists of installing a natural gas boiler for steam production covering the electricity demand from the grid. The CO 2 emissions from both options are compared regarding different kinds of generation mixes from the electricity grid in the case of using the industrial boiler; taking into account the advantages of using biomass in relation to emissions, a last comparison has been carried out considering a biomass boiler instead of the natural gas boiler. (author)

  20. Large-scale integration of off-shore wind power and regulation strategies of cogeneration plants in the Danish electricity system

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2005-01-01

    The article analyses how the amount of a small-scale CHP plants and heat pumps and the regulation strategies of these affect the quantity of off-shore wind power that may be integrated into Danish electricity supply......The article analyses how the amount of a small-scale CHP plants and heat pumps and the regulation strategies of these affect the quantity of off-shore wind power that may be integrated into Danish electricity supply...

  1. A basic analysis of cogeneration economics

    NARCIS (Netherlands)

    Collet, P.J.

    1989-01-01

    The economics of small scale gas turbine based cogeneration systems are analyzed on the basis of avoided costs for an electric utility exploiting such systems. This concerns a theoretical study in which the cogeneration system as a means for electricity generation is assumed to supplant the building

  2. Cogeneration development and market potential in China

    Energy Technology Data Exchange (ETDEWEB)

    Yang, F.; Levine, M.D.; Naeb, J. [Lawrence Berkeley Lab., CA (United States); Xin, D. [State Planning Commission of China, Beijing, BJ (China). Energy Research Inst.

    1996-05-01

    China`s energy production is largely dependent on coal. China currently ranks third in global CO{sub 2} emissions, and rapid economic expansion is expected to raise emission levels even further in the coming decades. Cogeneration provides a cost-effective way of both utilizing limited energy resources and minimizing the environmental impacts from use of fossil fuels. However, in the last 10 years state investments for cogeneration projects in China have dropped by a factor of 4. This has prompted this study. Along with this in-depth analysis of China`s cogeneration policies and investment allocation is the speculation that advanced US technology and capital can assist in the continued growth of the cogeneration industry. This study provides the most current information available on cogeneration development and market potential in China.

  3. Management decisions for cogeneration: executive summary

    Energy Technology Data Exchange (ETDEWEB)

    Radcliffe, R.R.; Tabors, R.D.

    1982-07-01

    This report summarizes two interdependent studies which explore the underlying factors in the decision by private, private non-profit, and public sector facility owners to invest in cogeneration technology. They employ factor analysis techniques to explain the decision to invest and discriminant analysis to group the survey respondents into non-cogenerators and potential cogenerators. Data for both studies come from a survey of commercial, industrial, and institutional electric energy consumers who used more than 750 kW demand in any one month of 1981 for a selected electric utility in the Boston area. There were 129 usable responses to the survey of 32.2% of the population. The studies reported here confirm that a number of factors other than purely economic considerations may prevent use of cogeneration technology at the present time. These factors include: uncertainty caused by regulatory action; desire for energy self sufficiency by the organization; financial flexibility; experience with electricity cogeneration or self generation; and capital budget planning methods. These studies provide a ranking of the factors involved in the cogeneration decision explaining most variance to least variance. However, the ranking of factors provides no measure of the importance of these factors in the decision to adopt or not adopt cogeneration technology. The results of these studies can be used to provide a rough estimate of capacity (kW) and energy (kWh) available from potential cogenerators in this electric utility service territory and the probability that a facility can be a cogenerator. These studies project a maximum potential of 106 MW and 559,000 MWH of cogenerated electrical energy in the utility service territory between 1982 and 2002.

  4. Case history study of cogeneration facility at Southeast Missouri State University, Cape Girardeau, Missouri

    Energy Technology Data Exchange (ETDEWEB)

    1977-09-01

    The Southeast Missouri State University total energy plant, its fuel, control, production, operation, and maintenance are examined. A financial analysis looks at comparative operating costs for central heating (case 1), stand along (case 2), and cogeneration (case 3). Finally an evaluation of the performance of the plant indicates continuation of operation with some modifications.

  5. Multi-criteria optimization of a district cogeneration plant integrating a solid oxide fuel cell-gas turbine combined cycle, heat pumps and chillers

    Energy Technology Data Exchange (ETDEWEB)

    Burer, M.; Favrat, D. [Swiss Federal Institute of Technology, Lausanne (Switzerland). Institute of Energy Science; Tanaka, K. [UMIST, Tyndall Centre, Manchester (United Kingdom); Yamada, K. [Shinshu University, Nagano (Japan). Department of Fine Materials Engineering

    2003-05-01

    A simultaneous optimization of the design and operation of a district heating, cooling and power generation plant supplying a small stock of residential buildings has been undertaken with regards to cost and CO{sub 2} emissions. The simulation of the plant considers a superstructure including a solid oxide fuel cell-gas turbine combined cycle, a compression heat pump, a compression chiller and/or an absorption chiller and an additional gas boiler. The Pareto-frontier obtained as the global solution of the optimization problem delivers the minimal CO{sub 2} emission rates, achievable with the technology considered for a given accepted investment, or respectively the minimal cost associated with a given emission abatement commitment. (author)

  6. Development of high-strength concrete mix designs in support of the prestressed concrete reactor vessel design for a HTGR steam cycle/cogeneration plant

    International Nuclear Information System (INIS)

    Naus, D.J.; Oland, C.B.

    1985-01-01

    Design optimization studies indicate that a significant reduction in the size of the PCRV for a 2240 MW(t) HTGR plant can be effected through utilization of high-strength concrete in conjunction with large capacity prestressing systems. A three-phase test program to develop and evaluate high-strength concretes (>63.4 MPa) is described. Results obtained under Phase I of the investigation related to materials selection-evaluation and mix design development are presented. 3 refs., 4 figs

  7. Influence of biomass cofiring on the optimal coefficient of the cogeneration share in a district heating system

    Directory of Open Access Journals (Sweden)

    Ziębik Andrzej

    2014-03-01

    Full Text Available The paper presents a modified algorithm for choosing the optimal coefficient of the share of cogeneration in district heating systems taking into account additional benefits concerning the promotion of highefficiency cogeneration and biomass cofiring. The optimal coefficient of the share of cogeneration depends first of all on the share of the heat required for preparing the hot tap water. The final result of investigations is an empirical equation describing the influence of the ratio of the heat flux for the production of hot tap water to the maximum flux for space heating and ventilation, as well as the share of chemical energy of biomass in the fuel mixture on the optimal value of the share of cogeneration in district heating systems. The approach presented in the paper may be applied both in back-pressure combined heat and power (CHP plants and in extraction-condensing CHP plants.

  8. Optimal energy exchange of an industrial cogeneration in a day-ahead electricity market

    International Nuclear Information System (INIS)

    Yusta, J.M.; De Oliveira-De Jesus, P.M.; Khodr, H.M.

    2008-01-01

    This paper addresses an optimal strategy for the daily energy exchange of a 22-MW combined-cycle cogeneration plant of an industrial factory operating in a liberalized electricity market. The optimization problem is formulated as a Mixed-Integer Linear Programming Problem (MILP) that maximizes the profit from energy exchange of the cogeneration, and is subject to the technical constraints and the industrial demand profile. The integer variables are associated with export or import of electricity whereas the real variables relate to the power output of gas and steam turbines, and to the electricity purchased from or sold to the market. The proposal is applied to a real cogeneration plant in Spain where the detailed cost function of the process is obtained. The problem is solved using a large-scale commercial package and the results are discussed and compared with different predefined scheduling strategies. (author)

  9. Feasibility study for retrofitting biogas cogeneration systems to district heating in South Korea.

    Science.gov (United States)

    Chung, Mo; Park, Hwa-Choon

    2015-08-01

    A feasibility study was performed to assess the technical and economic merits of retrofitting biogas-based cogeneration systems to district heating networks. Three district heating plants were selected as candidates for accommodating heat recovery from nearby waste treatment stations, where a massive amount of biogas can be produced on a regular basis. The scenario involves constructing cogeneration systems in each waste treatment station and producing electricity and heat. The amounts of biogas production for each station are estimated based on the monthly treatment capacities surveyed over the most recent years. Heat produced by the cogeneration system is first consumed on site by the waste treatment system to keep the operating temperature at a proper level. If surplus heat is available, it will be transported to the nearest district heating plant. The year-round operation of the cogeneration system was simulated to estimate the electricity and heat production. We considered cost associated with the installation of the cogeneration system and piping as initial investments. Profits from selling electricity and recovering heat are counted as income, while costs associated with buying biogas are expenses. Simple payback periods of 2-10 years were projected under the current economic conditions of South Korea. We found that most of the proposed scenarios can contribute to both energy savings and environmental protection. © The Author(s) 2015.

  10. Tax issues in structuring effective cogeneration vehicles

    International Nuclear Information System (INIS)

    Ebel, S.R.

    1999-01-01

    An overview of the Canadian income tax laws that apply to cogeneration projects was presented. Certain tax considerations could be taken into account in deciding upon ownership and financing structures for cogeneration projects, particularly those that qualify for class 43.1 capital cost allowance treatment. The tax treatment of project revenues and expenses were described. The paper also reviewed the 1999 federal budget proposals regarding the manufacturing and processing tax credit, the capital cost allowance system applicable to cogeneration assets and the treatment of the Canadian renewable conservation expense

  11. HTTR demonstration program for nuclear cogeneration of hydrogen and electricity

    International Nuclear Information System (INIS)

    Sato, Hiroyuki; Sumita, Junya; Terada, Atsuhiko; Ohashi, Hirofumi; Yan, Xing L.; Nishihara, Tetsuo; Tachibana, Yukio; Inagaki, Yoshiyuki

    2015-01-01

    Japan Atomic Energy Agency initiated a High Temperature Engineering Test Reactor (HTTR) demonstration program in accordance with recommendations of a task force established by Ministry of Education, Culture, Sports, Science and Technology according to the Strategic Energy Plan as of April 2014. The demonstration program is designed to complete helium gas turbine and hydrogen production system technologies aiming at commercial plant deployment in 2030s. The program begins with coupling a helium gas turbine in the secondary loop of the HTTR and expands by adding the H 2 plant to a tertiary loop to enable hydrogen cogeneration. Safety standards for coupling the helium gas turbine and H 2 plant to the nuclear reactor will be established through safety review in licensing. A system design and its control method are planned to be validated with a series of test operations using the HTTR-GT/H 2 plant. This paper explains the outline of HTTR demonstration program with a plant concept of the heat application system directed at establishing an HTGR cogeneration system with 950°C reactor outlet temperature for production of power and hydrogen as recommended by the task force. Commercial deployment strategy including a development plan for the helium gas turbine is also presented. (author)

  12. System analysis of CO{sub 2} sequestration from biomass cogeneration plants (Bio-CHP-CCS). Technology, economic efficiency, sustainability; Systemanalyse der CO{sub 2}-Sequestrierung aus Biomasse-Heizkraftwerken (Bio-KWK-CCS). Technik, Wirtschaftlichkeit, Nachhaltigkeit

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Claus

    2014-10-15

    In the present work a system analysis is carried out to determine the extent to which a combination of the three areas of energetic biomass use, combined heat and power (CHP) and CO{sub 2} sequestration (CCS - Carbon Capture and Storage) is fundamentally possible and meaningful. The term ''CO{sub 2} sequestration'' refers to the process chain from CO{sub 2} capture, CO{sub 2} transport and CO{sub 2} storage. While the use of biomass in combined heat and power plants is a common practice, CO{sub 2} sequestration (based on fossil fuels) is at the research and development stage. A combination of CCS with biomass has so far been little studied, a combination with combined heat and power plants has not been investigated at all. The two technologies for the energetic use of biomass and cogeneration represent fixed variables in the energy system of the future in the planning of the German federal government. According to the lead scenario of the Federal Ministry of the Environment, electricity generation from biomass is to be almost doubled from 2008 to 2020. At the same time, the heat generated in cogeneration is to be trebled [cf. Nitsch and Wenzel, 2009, p. 10]. At the same time, the CCS technology is to be used in half of all German coal-fired power plants until 2030 [cf. Krassuki et al., 2009, p. 17]. The combination of biomass and CCS also represents an option which is conceivable for the German federal policy [cf. Bundestag, 2008b, p. 4]. In addition, the CCS technology will provide very good export opportunities for the German economy in the future [cf. Federal Government, 2010, p. 20]. The combination of biomass combined heat and power plants with CCS offers the interesting opportunity to actively remove CO{sub 2} from the atmosphere as a future climate protection instrument by means of CO{sub 2} neutrality. Therefore, in the energy concept of the German federal government called for a storage project for industrial or biogenic CO{sub 2

  13. Thermal energy storage for cogeneration applications

    Energy Technology Data Exchange (ETDEWEB)

    Drost, M.K.; Antoniak, Z.I.

    1992-04-01

    Cogeneration is playing an increasingly important role in providing energy efficient power generation and thermal energy for space heating and industrial process heat applications. However, the range of applications for cogeneration could be further increased if the generation of electricity could be coupled from the generation of process heat. Thermal energy storage (TES) can decouple power generation from the production of process heat, allowing the production of dispatchable power while fully utilizing the thermal energy available from the prime mover. The Pacific Northwest Laboratory (PNL) leads the US Department of Energy`s Thermal Energy Storage Program. The program focuses on developing TES for daily cycling (diurnal storage), annual cycling (seasonal storage), and utility applications (utility thermal energy storage (UTES)). Several of these technologies can be used in a cogeneration facility. This paper discusses TES concepts relevant to cogeneration and describes the current status of these TES systems.

  14. Thermal energy storage for cogeneration applications

    Energy Technology Data Exchange (ETDEWEB)

    Drost, M.K.; Antoniak, Z.I.

    1992-04-01

    Cogeneration is playing an increasingly important role in providing energy efficient power generation and thermal energy for space heating and industrial process heat applications. However, the range of applications for cogeneration could be further increased if the generation of electricity could be coupled from the generation of process heat. Thermal energy storage (TES) can decouple power generation from the production of process heat, allowing the production of dispatchable power while fully utilizing the thermal energy available from the prime mover. The Pacific Northwest Laboratory (PNL) leads the US Department of Energy's Thermal Energy Storage Program. The program focuses on developing TES for daily cycling (diurnal storage), annual cycling (seasonal storage), and utility applications (utility thermal energy storage (UTES)). Several of these technologies can be used in a cogeneration facility. This paper discusses TES concepts relevant to cogeneration and describes the current status of these TES systems.

  15. 'BACO' code: Cogeneration cycles heat balance

    International Nuclear Information System (INIS)

    Huelamo Martinez, E.; Conesa Lopez, P.; Garcia Kilroy, P.

    1993-01-01

    This paper presents a code, developed by Empresarios Agrupados, sponsored by OCIDE, CSE and ENHER, that, with Electrical Utilities as final users, allows to make combined and cogeneration cycles technical-economical studies. (author)

  16. Simulation of power- and cogeneration plants. Comparison of software for thermodynamic process calculation; Modellierung von Kraft- und Heizkraftwerken. Vergleich von Software zur thermodynamischen Prozessrechnung

    Energy Technology Data Exchange (ETDEWEB)

    Giglmayr, E.

    2001-07-01

    Great demands related to the quick availability of the energy generated and to the ecological operating mode of existing power plants are today being made on the public and private utility companies because of the liberalisation of the electricity market and the ever-increasing environmental conditions and constraints imposed upon them. Over the past thirty years, numeric studies of the operating behaviour beyond the design point, repowering studies and efforts to optimise and dimension new plants in the most precise way possible have entailed the development of a wide range of methods of analysis and solution algorithms. The application of these methods and algorithms is supported by a variety of commercially available simulation programmes designed for the thermodynamic process calculation with their graphical user interfaces. From several small-scale studies carried out over the past years it has emerged, however, that many of these programmes do not meet all requirements for the calculation of power plant cycles. The aim of this study was to explore in detail and evaluate 16 commercially available programmes offered by vendors from 7 different countries. Essentially, the method for comparing the performance of these programmes was the utility value analysis. Since the requirements to be met by the programmes differ widely, no generally valid ranking or recommendation can be given. However, the programme Quick Select developed in the course of this PhD-thesis in order to cope with the great variety of data, offers the potential user the possibility to establish a ranking of the programmes according to his/her own requirements. This ranking does not reflect differences in quality but priorities according to the individual requirements. With the additional remarks and detailed information given by Quick Select on the software analysed, the programme provides comprehensive support in choosing a software suited to the individual demands. In the second part of this

  17. Analysis of possible energy efficiency increasing of the cogeneration process in EL-TO Zagreb

    International Nuclear Information System (INIS)

    Stanisa, B.; Krivak, B.

    1996-01-01

    In the erection planing of new generation capacity, besides the profitability, there is need to taken in account the rational consumption of primary energy, and the environmental protection. The main rules could have cogenerations of the heat and power. In power plant EL-TO Zagreb there are analysed generating capacity of the cogeneration process. There is considered reconstruction and revitalisation's of existing generating units, and erections of new one, all in the purpose to meet the growing heat demand. The district heating system is considered from the point as opportunity in energy saving capacity in the cogeneration of heat and power. For the amount of the energy saved there is need for less primary energy to be consumed, and this in finally means that for the some energy demands it has the some effect as the natural energy resources are expanded. (author)

  18. Energy and cost saving results for advanced technology systems from the Cogeneration Technology Alternatives Study (CTAS)

    Science.gov (United States)

    Sagerman, G. D.; Barna, G. J.; Burns, R. K.

    1979-01-01

    An overview of the organization and methodology of the Cogeneration Technology Alternatives Study is presented. The objectives of the study were to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the future and to assess the advantages of advanced technology systems compared to those systems commercially available today. Advanced systems studied include steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics. Steam turbines, open cycle gas turbines, combined cycles, and diesel engines were also analyzed in versions typical of today's commercially available technology to provide a base against which to measure the advanced systems. Cogeneration applications in the major energy consuming manufacturing industries were considered. Results of the study in terms of plant level energy savings, annual energy cost savings and economic attractiveness are presented for the various energy conversion systems considered.

  19. State Support for Promotion of Electrical Energy Produced in High Efficiency Cogeneration in Romania

    Directory of Open Access Journals (Sweden)

    Mushatescu V.

    2016-12-01

    Full Text Available Romania accumulated a useful experience in supporting high efficient cogeneration through a bonus type scheme. Spreading this experience to other countries that can choose a similar support scheme could lead to important savings and better results in developing this efficient tool. This state aid is operational, targeted to new investments stimulation for cogeneration technologies and replacement or existing plants rehabilitation. Present paper focuses on the results of support scheme after five years of its application: increase of number of producers who benefit of this aid, raising of general efficiency of high efficient cogeneration, important savings of primary energy and CO2 emissions avoided. On the other hand, use of this scheme showed a number of problems (to which this paper proposes adequate solutions on institutional/administrative, investition, technical, economical-financial and social frameworks that influences beneficiaries and/or financiers of state aid.

  20. Termoacu Cogeneration: gas, power and oil; Cogeracao Termoacu: gas, energia e oleo

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Geraldo Jose; Gomes, Cicero Sena Moreira [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2004-07-01

    This paper describes the evolution of a project that involves cogeneration of power and steam for continuous injection in oil wells in the fields of Alto do Rodrigues and Estreito, in Rio Grande do Norte, Brazil. The project combines a PETROBRAS intention for recovering heavy oil in that area with partners intention of generating power to connect in a critical point of the Brazilian Electric System. PETROBRAS studies began in the nineties, when oil wells in that area became old end showed the necessity of some oil recovery technology. In 1999, PETROBRAS and Guaraniana made a partnership for implementation of Termoacu Combined Cycle, that would begin operation as a cogeneration plant for thirteen years, and as combined cycle from that point. The profile of steam injection has been adapted to a new one to comply with the powe r capacity of the Plant, and will operate eight years as a cogeneration plant , four years as a combined cycle with cogeneration and after twelve years as a complete combined cycle with 500 MW of capacity. The project integrates a gas pipeline, a Thermal Power Plant, a Transmission Line to connect to the grid and a Steam Pipeline for steam injection at Estreito and Alto do Rodrigues fields. (author)

  1. COGENERATION IN AIR SEPARATION CRIOGENIC PLANTS

    OpenAIRE

    WALTER NOVELLO BASTOS

    1999-01-01

    Diante da crise energética e de mercado a Cogeração se apresenta oportuna tanto para a produção de energias elétrica e térmica quanto para a redução dos custos operacionais de produção de uma empresa. Um sistema de cogeração integrado e adaptado ao processo de uma Planta Criogênica de Separação de Ar, que tem a energia elétrica como insumo básico, pois o ar não tem custo, pode se mostrar viável, com considerável redução nos custos operacionais da planta. Um estudo termoeconômico, englob...

  2. Cogeneration cycles applied to desalination in the Arab World: state of the art

    International Nuclear Information System (INIS)

    Yassin, Jamal Saleh

    2006-01-01

    This paper presents a review of cogeneration cycles applied to water desalination in most of the Arab countries. The scarcity of fresh water resources in many countries around the world, and in particular Gulf countries and north African countries such as Libya and Tunisia forced the local authorities to establish many desalination plants to compensate the water shortage. Some plants are conventional for desalination processes only and others are with cogeneration cycle. The high performance of cogeneration cycles encouraged establishing combined power and desalination plants. The present study is intended to provide an overview of cogeneration cycles in conjunction with desalination technologies under the two main resources of energy, fossils and renewables. Thermal technologies, which utilize fossil resource constitute the mainstay of large-scale desalination in the Arab countries and enjoy a relatively important position worldwide. While the technologies which utilize renewable resources such as solar are getting more attention year by year and still under research and almost for small units.(Author)

  3. CANDU co-generation opportunities

    International Nuclear Information System (INIS)

    Meneley, D.A.; Duffey, R.B.; Pendergast, D.R.

    2000-01-01

    Modern technology makes use of natural energy 'wealth' (uranium) to produce useful energy 'currency' (electricity) that can be used to society's benefit. This energy currency can be further applied to help solve a difficult problem faced by mankind. Within the next few years we must reduce our use of the same fuels which have made many countries wealthy - fossil fuels. Fortunately, electricity can be called upon to produce another currency, namely hydrogen, which has some distinct advantages. Unlike electricity, hydrogen can be stored and can be recovered for later use as fuel. It also is extremely useful in chemical processes and refining. To achieve the objective of reducing greenhouse gas emissions hydrogen must, of course, be produced using a method which does not emit such gases. This paper summarizes four larger studies carried out in Canada in the past few years. From these results we conclude that there are several significant opportunities to use nuclear fission for various co-generation technologies that can lead to more appropriate use of energy resources and to reduced emissions. (author)

  4. Combined cycles and cogeneration with natural gas and alternative fuels

    International Nuclear Information System (INIS)

    Gusso, R.

    1992-01-01

    Since 1985 there has been a sharp increase world-wide in the sales of gas turbines. The main reasons for this are: the improved designs allowing better gas turbine and, thus, combined cycle efficiencies; the good fuel use indices in the the case of cogeneration; the versatility of the gas turbines even with poly-fuel plants; greatly limited exhaust emissions; and lower manufacturing costs and delivery times with respect to conventional plants. This paper after a brief discussion on the evolution in gas turbine applications in the world and in Italy, assesses their use and environmental impacts with fuels other than natural gas. The paper then reviews Italian efforts to develop power plants incorporating combined cycles and the gasification of coal, residual, and other low calorific value fuels

  5. GTHTR300 cost reduction through design upgrade and cogeneration

    International Nuclear Information System (INIS)

    Yan, Xing L.; Sato, Hiroyuki; Kamiji, Yu; Imai, Yoshiyuki; Terada, Atsuhiko; Tachibana, Yukio; Kunitomi, Kazuhiko

    2014-01-01

    Japan Atomic Energy Agency began design and development of the Gas Turbine High Temperature Reactor of 300MWe nominal output (GTHTR300) in 2001. The reactor baseline design completed three years later was based on 850°C core outlet temperature and a direct cycle gas turbine balance of plant. It attained 45.6% net power generation efficiency and 3.5US¢/KWh cost of electricity. The cost was estimated 20% lower than LWR. The latest design upgrade has incorporated several major technological advances made in the past ten years to both reactor and balance of plant. As described in this paper, these advances have enabled raising the design basis reactor core outlet temperature to 950°C and increasing power generating efficiency by nearly 5% point. Further implementation of seawater desalination cogeneration is made through employing a newly-proposed multi-stage flash process. Through efficient waste heat recovery of the reactor gas turbine power conversion cycle, a large cost credit is obtained against the conventionally produced water prices. Together, the design upgrade and the cogeneration are shown to reduce the GTHTR300 cost of electricity to under 2.7 US¢/KWh. (author)

  6. Evaluation of potential for cogeneration of electricity and process heat in North Carolina. Final report, June 1, 1978-May 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    The objective of this study was to enable North Carolina to more efficiently utilize available energy than would be possible without additional cogeneration. Effective use of cogeneration can ease the requirement for utility capital and power plant sites and, by reducing fuel usage, can lead to less environmental damage. The study used the National Emissions Data System data bank and the North Carolina Boiler Registry to identify potential candidates for cogeneration and to then ascertain the magnitude of the potential in existing, new, and expanded facilities as a function of cogeneration impediment elimination. The survey uncovered 372 MW of operable cogeneration capacity in North Carolina in 15 plants. An estimate of the potential for expansion of cogeneration by firms presently operating in North Carolina amounted to 130 MW. This estimate was based on current conditions of fuel costs, electricity rates, standby charges, and investment tax credit. Much information is provided concerning industry and utilities in North Carolina, fuel usage by industry, and barriers to cogeneration. Recommendations are summarized.

  7. Electrification influence on cane crushers in the performance of a energy cogeneration plant of the sugar and alcohol sector; Influencia da eletrificacao de moendas no desempenho de uma planta de cogeracao de energia do setor sucroalcooleiro

    Energy Technology Data Exchange (ETDEWEB)

    Fiomari, Marcelo C. [Destilaria Pioneiros, Sud Mennucci, SP (Brazil)]. E-mail: marcelo.fiomari@pioneiros.com; Mashiba, Marcos H.S.; Beneduzzi, Anderson H.; Lima, Rodrigo S.; Dib, Fernando H.; Ramos, Ricardo A.V. [UNESP, Ilha Solteira, SP (Brazil). Faculdade de Engenharia. Dept. de Engenharia Mecanica]. E-mails: mashiba@dem.feis.unesp.br; ahbeneduzzi@dem.feis.unesp.br; rlima@dem.feis.unesp.br; fhdib@aluno.feis.unesp.br; ramos@dem.feis.unesp.br

    2006-07-01

    This paper performs a thermodynamic evaluation on the project of cogeneration energy system of the Destilaria Pioneiros. The first considered configuration is the resultant of the expansion process performed with the PROINFA support, which consisted in the substitution of the old boilers by one boiler producing steam to a more elevated process of pressure and temperature, and the single stage counter pressure turbines designed for self consumption electric power by a multiple stage extraction-condensation turbine for generation of electricity excess for commercialization.

  8. Extra cogeneration step seen boosting output 20%

    Energy Technology Data Exchange (ETDEWEB)

    Burton, P.

    1984-10-08

    Cogenerators can now buy a prototype 6.5 MW, pre-packaged cogeneration system that incorporates an added step to its cycle to reduce fuel use by 21%. Larger, custom-designed systems will be on the market in 1985. Fayette Manufacturing Co. will offer the Kalina Cycle system at a discount price of $8.2 million (1200/kW) until the systems are competitive with conventional units. The system varies from conventional cogeneration systems by adding a distillation step, which permits the use of two fluids for the turbine steam and operates at a higher thermodynamic efficiency, with boiling occuring at high temperature and low pressure. Although theoretically correct, DOE will withhold judgment on the system's efficiency until the first installation is operating.

  9. Thermoeconomic and exegetic analysis of a cogeneration proposal by using natural gas in breweries; Analise termoeconomica e exergetica de uma proposta de cogeracao usando gas natural em cervejarias

    Energy Technology Data Exchange (ETDEWEB)

    Gallego, Antonio Garrido; Martins, Gilberto [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara do Oeste, SP (Brazil). Faculdade de Engenharia Mecanica e de Producao]. E-mail: agallego@unimep.br; gmartins@unimep.br; Nebra, Silvia Azucena [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica]. E-mail: sanebra@fem.unicamp.br

    2000-07-01

    In this work the thermo economic method is used for analysis of the cost distribution in a cogeneration power plant proposed for a brewery in the Campinas - state of Sao Paulo, Brazil. The thermal process energy demands were considered for beer production in 1997. The proposed cogeneration system consists of two gas turbines with recovering boiler and ammonium compression cooling system. The present power generation configuration and the cogeneration proposed performance were simulated in a monthly basis, considering the month steam and refrigeration requests. The gas turbines were simulated considering the nominal load and the energy surplus sold to the concessionaire.

  10. Transient behaviour of small HTR for cogeneration

    International Nuclear Information System (INIS)

    Verkerk, E.C.; Van Heek, A.I.

    2000-01-01

    The Dutch market for combined generation of heat and power identifies a unit size of 40 MW thermal for the conceptual design of a nuclear cogeneration plant. The ACACIA system provides 14 MWe electricity combined with 17 t/h of high temperature steam (220 deg C, 10 bar) with a pebble-bed high temperature reactor directly coupled with a helium compressor and a helium turbine. The design of this small CHP unit that is used for industrial applications is mainly based on a pre-feasibility study in 1996, performed by a joint working group of five Dutch organisations, in which technical feasibility was shown. Thermal hydraulic and reactor physics analyses show favourable control characteristics during normal operation and a benign response to loss of helium coolant and loss of flow conditions. Throughout the response on these highly infrequent conditions, ample margin exists between the highest fuel temperatures and the temperature above which fuel degradation will occur. To come to quantitative statements about the ACACIA transient behaviour, a calculational coupling between the high temperature reactor core analysis code package PANTHER/DIREKT and the thermal hydraulic code RELAP5 for the energy conversion system has been made. This coupling offers a more realistic simulation of the entire system, since it removes the necessity of forcing boundary conditions on the simulation models at the data transfer points. In this paper, the models used for the dynamic components of the energy conversion system are described, and the results of the calculation for two operational transients in order to demonstrate the effects of the interaction between reactor core and its energy conversion system are shown. Several transient cases that are representative as operational transients for an HTR will be discussed, including one representing a load rejection case that shows the functioning of the control system, in particular the bypass valve. Another transient is a load following

  11. Micro-cogeneration with fuel cells

    Science.gov (United States)

    Patsch, Marek; Čierny, Jaroslav

    2014-08-01

    The article is aimed at perspective and fast developing field of micro-cogeneration with small performance. Fuel cell application which uses natural gas as a fuel is high sophisticated technology of combined produce of heat and electric power. The aim of article is analysis of operation parameters of micro-cogeneration unit with fuel cell which as a fuel uses natural gas. The device is installed in University of Zilina laboratory. Measured parameters were electric input and output, thermal energy and electric, thermal and overall efficiency.

  12. Potable water cogeneration using nuclear power

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, G. [Instituto Nacional de Investigaciones Nucleares, Estado de Mexico (Mexico); Instituto Politecnico Nacional, Escuela Superior de Fisica y Matematicas, D.F. (Mexico); Ramirez, J.R. [Instituto Nacional de Investigaciones Nucleares, Estado de Mexico (Mexico); Valle, E. del [Instituto Politecnico Nacional, Escuela Superior de Fisica y Matematicas, D.F. (Mexico)

    2014-07-01

    Mexico is a country with a diversity of conditions; the Peninsula of Baja California is a semi-arid region with a demand of potable water and electricity where small nuclear power can be used. This part of the country has a low density population, a high pressure over the water resources in the region, and their needs of electricity are small. The SMART reactor will be assessed as co-generator for this region; where five different scenarios of cogeneration of electricity and potable water production are considered, the levelized cost of electricity and potable water are obtained to assess their competitiveness. (author)

  13. District heating/cogeneration application studies for the Minneapolis-St Paul area. Executive summary; overall feasibility and economic viability for a district heating/new cogeneration system in Minneapolis-St. Paul

    Energy Technology Data Exchange (ETDEWEB)

    Margen, P.; Larsson, K.; Cronholm, L.A.; Marklund, J.E.

    1979-08-01

    A study was undertaken to determine the feasibility of introducing a large-scale, hot-water, district-heating system for the Minneapolis-St. Paul area. The analysis was based on modern European hot-water district-heating concepts in which cogeneration power plants supply the base-load thermal energy. Heat would be supplied from converted turbines of existing coal-fired power plants in Minneapolis and St. Paul. Toward the end of the 20-year development period, one or two new cogeneration units would be required. Thus, the district-heating system could use low-grade heat from either coal-fired or nuclear cogeneration power stations to replace the space-heating fuels currently used - natural gas and distillate oil. The following conclusions can be drawn: the concept is technically feasible, it has great value for fuel conservation, and with appropriate financing the system is economically viable.

  14. A simulation model for Carson Ice Co-Generation Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, N.K.W.; Elmasri, M. [Thermoflow, Inc., Wellesley, MA (United States); Brownell, G. [SMUD, Sacramento, CA (United States)

    1995-12-31

    The paper describes a software system to simulate the performance of the Carson Ice Co-gen Facility operated by the Carson Energy Group. This 100 MW plant consists of a cogeneration combined cycle and a simple cycle unit powered by LM6000 gas turbine generators. Features of the system include inlet heating/absorption chilling for the gas turbines, supplementary firing capability, and a broad range of steam turbine extractions and admissions. The software enables the operator to model complex operating scenarios. It predicts technical and economic performance under a wide range of conditions, taking into account various equipment constraints and operation preferences. For any set of user-specified operating inputs, the corresponding heat and mass balance diagrams as well as economic figures may be viewed virtually instantaneously. Interactive plots of plant heat rate, incremental heat rate, operating income, and other parameters reveal issues and trade-offs involved in performance and economic optimization.

  15. Cogeneration technology alternatives study. Volume 6: Computer data

    Science.gov (United States)

    1980-01-01

    The potential technical capabilities of energy conversion systems in the 1985 - 2000 time period were defined with emphasis on systems using coal, coal-derived fuels or alternate fuels. Industrial process data developed for the large energy consuming industries serve as a framework for the cogeneration applications. Ground rules for the study were established and other necessary equipment (balance-of-plant) was defined. This combination of technical information, energy conversion system data ground rules, industrial process information and balance-of-plant characteristics was analyzed to evaluate energy consumption, capital and operating costs and emissions. Data in the form of computer printouts developed for 3000 energy conversion system-industrial process combinations are presented.

  16. Co-generation potentials of municipal solid waste landfills in Serbia

    Directory of Open Access Journals (Sweden)

    Bošković Goran B.

    2016-01-01

    Full Text Available Waste management in the Republic of Serbia is based on landfilling. As a result of such year-long practice, a huge number of municipal waste landfills has been created where landfill gas has been generated. Landfill gas, which is essentially methane (50-55% and carbon dioxide (40-45% (both GHGs, has a great environmental impact which can be reduced by using landfill gas in cogeneration plants to produce energy. The aim of this paper is to determine economic and environmental benefits from such energy production. For that purpose, the database of cogeneration potentials (CP of 51 landfills in the Republic of Serbia (RS was created. Amount of landfill gas generated at each municipal landfill was calculated by applying a first order decay equation which requires the data about solid waste production and composition and about some landfill characteristics. For all landfills, which have over 100,000 m3 each, a techno-economic analysis about building a CHP plant was conducted. The results have shown, that the total investment in 14 CHP plants with payback period of less than 7 years amounts € 11,721,288. The total nominal power of these plants is 7 MW of electrical power and 7.9 MW of thermal power, and an average payback period is about 61 months. In addition, using landfill biogas as energy source in proposed plants would reduce methane emission for 161,000 tons of CO2 equivalent per year. [Projekat Ministarstva nauke Republike Srbije, br. III 42013: Research of cogeneration potential of municipal and industrial energy power plant in Republic of Serbia and opportunities for rehabilitation of existing and construction of new cogeneration plants

  17. Waste-to-Energy Cogeneration Project, Centennial Park

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Clay; Mandon, Jim; DeGiulio, Thomas; Baker, Ryan

    2014-04-29

    The Waste-to-Energy Cogeneration Project at Centennial Park has allowed methane from the closed Centennial landfill to export excess power into the the local utility’s electric grid for resale. This project is part of a greater brownfield reclamation project to the benefit of the residents of Munster and the general public. Installation of a gas-to-electric generator and waste-heat conversion unit take methane byproduct and convert it into electricity at the rate of about 103,500 Mwh/year for resale to the local utility. The sale of the electricity will be used to reduce operating budgets by covering the expenses for streetlights and utility bills. The benefits of such a project are not simply financial. Munster’s Waste-to Energy Cogeneration Project at Centennial Park will reduce the community’s carbon footprint in an amount equivalent to removing 1,100 cars from our roads, conserving enough electricity to power 720 homes, planting 1,200 acres of trees, or recycling 2,000 tons of waste instead of sending it to a landfill.

  18. Energy conservation through the implementation of cogeneration and grid interconnection

    International Nuclear Information System (INIS)

    Dashash, M. A.

    2007-01-01

    With increasing awareness of energy conservation and environmental protection, the Arab World is moving to further improve energy conversion efficiency. The equivalent of over 2.7 MM bbl is being daily burnt to fuel the thermal power plants that represent 92% of the total Arab power generation. This adds up to close to one billion barrels annually. At a conservative 30$ per barrel, this represents a daily cost of over $81 Million. This paper will introduce two strategies with the ultimate objective to cut-off up to half of the current fuel consumption. Firstly, Cogeneration Technology is able to improve thermal efficiency from the current average of less than 25% to up to 80%. Just 1% improvement in power plant thermal efficiency represents 3 million $/day in fuel cost savings. In addition, a well-designed and operated cogeneration plant will: - Reduce unfriendly emissions by burning less fuel as a result of higher thermal efficiency, - Increase the decentralization of electrical generation, - Improve the reliability of electricity supply. As an example, the Kingdom of Saudi Arabia's experience of implementing cogeneration will be presented, in particular within its hydrocarbon facilities and desalination plants. This will include the existing facilities and the planned and on-going projects. Secondly, by interconnecting the power networks of all the adjacent Arab countries, the following benefits could be reached: - Reduce generation reserves and enhance the system reliability, - Improve the economic efficiency of the electricity power systems, - Provide power exchange and strengthen the supply reliability, - Adopt technological development and use the best modern technologies. At least two factors plead for this direction. On one hand, the four-hour time zone difference from Eastern to Western Arab World makes it easy to exchange power. On the other hand, this will help to reduce the reserve capacity and save on corresponding Capital investment, fuel, and O and M

  19. 10 CFR 503.37 - Cogeneration.

    Science.gov (United States)

    2010-01-01

    ... is to use distillate oil. It will have a capacity of 50 MW, an average annual heat rate of 7600 BTU/KWHR, and be operated at a capacity factor of 90%. The annual fuel consumption is therefore calculated... Cogeneration. The following table may be used to determine eligibility for a permanent exemption based on oil...

  20. Feasibility study on the co-generation of ethylene and electricity through oxidative coupling of methane

    International Nuclear Information System (INIS)

    Hugill, J.A.; Tillemans, F.W.A.; Dijkstra, J.W.; Spoelstra, S.

    2005-01-01

    Ethylene is the most important base chemical in the petrochemical industry. One alternative route for the production of ethylene is from natural gas via oxidative coupling of methane. So far the process is economically unfeasible. However, recent studies suggest that this may be overcome by producing not only ethylene but also electricity, using the heat from the very exothermic coupling reaction.In this work we have compared this co-generation scheme with a scheme in which ethylene (106kt/y) and electricity (44MW) are generated separately by conventional processes in the Netherlands. It was concluded that: Energy savings are probably not significant. CO 2 emissions are reduced significantly. Also, since the CO 2 is obtained as a pure by-product, it may be feasible to reduce these emissions to zero. Costs: co-generation has a rather low profitability, lower than that of the conventional scheme. Furthermore, a number of alternatives to improve the co-generation scheme have been examined. The most promising (long-term) alternative to the fluidised-bed reactor for the oxidative coupling of methane is an oxygen-permeable membrane reactor, which by eliminating the need for an oxygen plant could give significant improvements in terms of energy efficiency, CO 2 emissions, and costs. This could make the co-generation scheme a viable option

  1. FBC utilization prospects in decentralized cogeneration units in Caucasus region countries

    Directory of Open Access Journals (Sweden)

    Skodras George

    2003-01-01

    Full Text Available Great differences are encountered among Caucasus region countries with respect to energy resources reserves and economic conditions. Thermal power plants consist of obsolete and inefficient units, while the Soviet-type large heating systems in the area collapsed after 1992 and their reconstruction is considered uneconomic. Renovation needs of the power and heat sector, and the potential of Fluidised Bed Combustion implementations in decentralized cogeneration units were investigated, since operating oil and gas power plants exhibit high fuel consumption, low efficiency and poor environmental performance. Results showed significant prospects of Fluidised Bed Combustion utilization in decentralized cogeneration units in the Caucausus region heat and power sector. Their introduction constitutes an economically attractive way to cover power and heat demands and promotes utilization of domestic energy resources in all of three countries, provided that financial difficulties could be confronted.

  2. Natural gas cogeneration in the residential sector; La cogeneration au gaz naturel en residentiel

    Energy Technology Data Exchange (ETDEWEB)

    Lancelot, C.; Gaudin, S. [Gaz de France, GDF, Dir. de la Recherche, 75 - Paris (France)

    2000-07-01

    The natural gas cogeneration offer is now available and operational in the industrial sector. It is based on technologies of piston engines and gas turbines. Currently, this offer is sufficiently diversified, so much from the point of view of the range of powers available (from 1 MW to more than 40 MW electric) that number of manufacturers. In order to widen the cogeneration market in France to the markets of the commercial and residential sectors, Gaz De France has undertaken a technical economic study to validate the potential of those markets. This study led to work on the assembly of a french die to cogeneration packages of low power (less than 1 MW electric). This step has emerged at the beginning of 1999 with the launching of a commercial offer of cogeneration packages. In margin to this work Gaz De France Research division also initiated a study in order to evaluate the offer of micro cogeneration, products delivering an electric output lower than 10 kW. (authors)

  3. System specification for Fort Hood Solar Cogeneration Facility

    Energy Technology Data Exchange (ETDEWEB)

    1981-05-01

    The characteristics and design and environmental requirements are specified for a solar cogeneration facility at the Fort Hood Army Base in Killeen, Texas. Characteristics of the system and major elements are described, and applicable standards, codes, laws and regulations are listed. Performance requirements for the total system and for each individual subsystem are presented. Survival requirements are given for various environmental extremes, with consideration given to lightning protection and effects of direct or adjacent lightning strikes. Air quality control standards are briefly mentioned. The facility operates in two principal modes: energy collection and energy utilization. The plant is capable of operating in either mode independently or in both modes simultaneously. The system is also operational in transitional and standby/inactive modes. (LEW)

  4. Case study of McCormick place cogeneration project

    Energy Technology Data Exchange (ETDEWEB)

    Overstreet, E.L.

    1994-12-31

    In the authors business of providing district energy services, competition is the key to his being able to have a positive impact on the environment, business stability, and economic activity. In the district energy industry, the competitive options are for property owners to continue to self generate energy to meet their needs, purchase energy from a company that utilizes electricity during off-peak hours to produce chilled water or take advantage of a total solution of purchasing tri-generation energy from Trigen-Peoples District Energy Company. Tri-generation is an innovative technology which involves the simultaneous production of steam, chilled water, and electricity. The McCormick Place cogeneration project calls for producing steam and chilled water (co-) for use by the Metropolitan Pier and Exposition Authority (MPEA). The plant will produce electricity (tri-) to run the production equipment.

  5. Case study of McCormick place cogeneration project

    International Nuclear Information System (INIS)

    Overstreet, E.L.

    1994-01-01

    In the authors business of providing district energy services, competition is the key to his being able to have a positive impact on the environment, business stability, and economic activity. In the district energy industry, the competitive options are for property owners to continue to self generate energy to meet their needs, purchase energy from a company that utilizes electricity during off-peak hours to produce chilled water or take advantage of a total solution of purchasing tri-generation energy from Trigen-Peoples District Energy Company. Tri-generation is an innovative technology which involves the simultaneous production of steam, chilled water, and electricity. The McCormick Place cogeneration project calls for producing steam and chilled water (co-) for use by the Metropolitan Pier and Exposition Authority (MPEA). The plant will produce electricity (tri-) to run the production equipment

  6. Independent power and cogeneration in Ontario's new competitive electricity market

    International Nuclear Information System (INIS)

    Barnstable, A.G.

    1999-01-01

    The factors influencing the initial market pricing in the early years of Ontario's new electricity market were discussed with particular insight on the potential for near term development of independent power and cogeneration. The major factors influencing prices include: (1) no increase in retail prices, (2) financial restructuring of Ontario Hydro, (3) the Market Power Mitigation Agreement, (4) tighter power plant emissions standards, and (5) an electricity supply and demand balance. Generation competition is not expected to influence market pricing in the early years of the new electricity market. Prices will instead reflect the restructuring decisions of the Ontario government. The decision to have Ontario Power Generation Inc. (OPGI) as a single generator for Ontario Hydro's generation assets will ensure that average spot market pricing in the early market years will be close to a 3.8 c/kWh revenue cap

  7. Gas turbine in cogeneration in a petrochemical industry; Turbina e gas em cogeracao numa industria petroquimica

    Energy Technology Data Exchange (ETDEWEB)

    Andreyevich, Svetislav Tomas [FINEGER S.A. Engenheiros Associados (Brazil)

    1994-12-31

    A feasibility study with technical and economical analyses about a new gas turbine, operating in a cogeneration process at a petrochemical plant, is developed comparative evaluations were made between various kinds of gas turbine, considering two different sceneries. The economic evaluation includes investments, financing, maintenance and operational costs, direct and indirect costs and tariffs. Energy and mass balances for each are also presented. 24 figs.

  8. Methodological specifics of the study of micro HPP based on internal combustion engines with air cooling and cogeneration

    Science.gov (United States)

    Shchinnikov, P. A.; Tomilov, V. G.; Sinelnikov, D. S.

    2017-01-01

    The article considers some aspects of the research methodology of micro heat power plants based on internal combustion engines with air cooling and cogeneration based on energy balance equations and the laws of heat transfer. The research is conducted for such a setup based on the Hitachi internal combustion engine with 2.4 kW capacity. It has shown the efficiency of cogeneration use in the form of useful heat flow from air, cooling the cylinder head, with its further heating by utilizing the heat of flue gases in an additional plate heat exchanger. It has been shown that the cogeneration can save fuel costs 3-10 times compared with heat guns, depending on the duration of the setup use.

  9. Qualifying cogeneration in Texas and Louisiana

    International Nuclear Information System (INIS)

    Jenkins, S.C.; Cabe, R.; Stauffaeher, J.J.

    1992-01-01

    This paper reports that cogeneration of electricity and useful thermal energy by industrials along the Gulf Coast grew significantly more rapidly than in other parts of the country during and immediately following World War II as a result of the concentration of chemical and plastics processing facilities there. In 1982, Texas passed its version of PURPA, the Public Utility Regulatory Act (PURA) and designated those non-utility generators from which public utilities must purchase electricity as Qualifying Cogenerators. In 1991, there were nearly 7,500 MW of QF power generated for inside-the-fence use or firm capacity sale to utilities, with the two largest utilities in Texas purchasing over half that amount

  10. Electricity and heat production by biomass cogeneration

    Science.gov (United States)

    Marčič, Simon; Marčič, Milan

    2017-07-01

    In Slovenia, approximately 2 % of electricity is generated using cogeneration systems. Industrial and district heating networks ensure the growth of such technology. Today, many existing systems are outdated, providing myriad opportunities for reconstruction. One concept for the development of households and industry envisages the construction of several small biomass units and the application of natural gas as a fuel with a relatively extensive distribution network. This concept has good development potential in Slovenia. Forests cover 56 % of the surface area in Slovenia, which has, as a result, a lot of waste wood to be turned into biomass. Biomass is an important fuel in Slovenia. Biomass is gasified in a gasifier, and the wood gas obtained is used to power the gas engine. This paper describes a biomass cogeneration system as the first of this type in Slovenia, located in Ruše.

  11. Experience feedback from nuclear cogeneration - 15369

    International Nuclear Information System (INIS)

    Auriault, C.; Fuetterer, M.A.; Baudrand, O.

    2015-01-01

    A consortium of 20 companies currently runs the NC2I-R (Nuclear Cogeneration Industrial Initiative - Research) project as part of the European Union's 7. Framework Programme. The project supports the development of an industrial initiative to demonstrate nuclear cogeneration of heat and power as an effective low-carbon technology for industrial market applications. As part of this project, operational feedback was collected from previous, existing and planned nuclear cogeneration projects in a number of countries with the aim of identifying a most complete set of boundary conditions which led to successful projects in the past. Stakeholders consulted include in particular utilities and end users. The scope encompassed technical and non-technical information (organizational structure, financial aspects, public relations, etc.) and specifically experience in licensing gained from these projects. The information was collected by a questionnaire and additional face-to-face interviews. The questionnaire was formulated to cover 9 categories of in total 56 questions for 36 identified projects: Motivation and initiative, Role of key players, Organizational structure, Technical aspects, Safety and licensing, Financial aspects, Timing, Public relations, General experience feedback. From the 36 identified projects worldwide, 23 from 10 countries have provided feedback on a variety of applications such as district heating, seawater desalination, paper and pulp industry, petrochemical industry, coal gasification or salt processing. This is a surprisingly positive response considering that several of these projects date back to the 1980's and many of them were performed outside Europe. This paper summarizes and analyzes the received information and deduces from there which boundary conditions are favorable for the construction of new nuclear cogeneration projects. (authors)

  12. Cogeneration. Section 2: Products and services

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This is a directory of suppliers of products and services in the area of cogeneration. The subheadings of this directory include developers and owner operators, system packagers, manufacturers of prime movers, equipment manufacturers, instruments and controls manufacturing, consulting services, appraisal and valuation, computer services, environmental services, feasibility services, hydrology, marketing, measurements, meteorology, regulatory and licensing, research, testing, training and personnel, engineering and construction, operations and maintenance, and insurance, financial and legal services

  13. The French stock of cogeneration equipment at 31 December 1997; Le parc francais des equipements de cogeneration au 31/12/1997

    Energy Technology Data Exchange (ETDEWEB)

    Secretariat d' Etat a l' Industrie [ed.] [Direction generale de l' energie et des matieres premieres, Secretariat d' Etat a l' Industrie, Paris (France)

    1999-07-01

    This study carried out by the General Direction for energy and raw materials of the State Secretariat for Industry of France presents the situation of the French stock of equipment for cogeneration extant at 31 December 1997. Industry, where the situation is rather well-known, and heating units in residential or service sector, as well as the heating grids and refuse-fueled plants are considered. The cogeneration of heat and motive power, often transformed in electricity, is recognized as privileged a way of sparing primary energy as long as it can be installed on sites where the simultaneous demand of heat and electricity (or motive power) is justified. The cogeneration stock as recorded at 31 December 1997 equals 940 units with 3,600 MW electric and 1,900 MW thermal total power. Their annual energy output is 11.6 TWh electricity and 44 TWh heat. The corresponding fuel consumption is 72 TWh or 6.2 Mtep. Other additional 90 units with 530 MW total electric are now under way. This equipment consists of 330 steam turbines, 105 combustion turbines and 505 heat engines. The stock is foreseen to grow significantly between 1998 and 2000. The reports gives details for each type of equipment as regarding the energy consumption, electric power (from < 1 MW to > 10 MW), age (from 4 month and less to 20 years and more), yield (from < 65% to {>=} 85%) and sector of application (industry, services, district heating, energy and water sector, agriculture). The equipment the installation of which is in progress in industry, service sector, district and grid heating, and in agriculture amounts 30, 17, 46 and 7, respectively. Responses to an inquiry concerning the equipment used in industry for cogeneration of heat/force in industry and energy sector, district and grid heating and service and agriculture are finally commented.

  14. Implementation of gas district cooling and cogeneration systems in Malaysia; Mise en oeuvre de systemes de gas district cooling et de cogeneration en Malaisie

    Energy Technology Data Exchange (ETDEWEB)

    Haron, S. [Gas District Cooling, M, Sdn Bhd (Malaysia)

    2000-07-01

    With its energy demand in the early 1990's growing at a high rate due to the country's strong economic growth, Malaysia studied various options to improve the efficiency of its energy use. Since its natural gas reserves are almost four times that of its crude oil reserves, efforts were therefore centered on seeking ways to boost the use of natural gas to mitigate the growing domestic energy need. PETRONAS, the national oil company, subsequently studied and chose the District Cooling System using natural gas as the primary source of fuel. The Kuala Lumpur City Center development, which houses the PETRONAS Twin Towers, was subsequently chosen as the first project to use the Gas District Cooling (GDC) System. To acquire the technology and implement this project, PETRONAS created a new subsidiary, Gas District Cooling (Malaysia) Sendirian Berhad (GDC(M)). In the process of improving the plant's efficiency, GDC(M) discovered that the GDC system's efficiency and project economics would be significantly enhanced if its is coupled to a Cogeneration system. Having proven the success of the GDC/Cogeneration system, GDC(M) embarked on a campaign to aggressively promote and seek new opportunities to implement the system, both in Malaysia-and abroad. Apart from enhancing efficiency of energy use, and providing better project economics, the GDC/Cogeneration system also is environment friendly. Today, the GDC/Cogeneration systems is the system of choice for several important developments in Malaysia, which also includes the country's prestigious projects such as the Kuala Lumpur International Airport and the New Federal Government Administrative Center in Putrajaya. (author)

  15. Geothermal GW cogeneration system GEOCOGEN

    Energy Technology Data Exchange (ETDEWEB)

    Grob, Gustav R.

    2010-09-15

    GEOCOGEN is the GW zero pollution, no risk solution to replace nuclear and fossil fuelled power plants. It can be built near the energy consumption centers, is invisible and produces electricity and heat at a fraction of the cost of any other the energy mix options. It is a break through deep well geothermal energy technology lasting forever driving also millions of electric vehicles.

  16. Cogeneration applications of biomass gasifier/gas turbine technologies in the cane sugar and alcohol industries

    International Nuclear Information System (INIS)

    Ogden, J.M.; Williams, R.H.; Fulmer, M.E.

    1994-01-01

    Biomass integrated gasifier/gas turbine (BIG/GT) technologies for cogeneration or stand-alone power applications hold forth the promise of being able to produce electricity at lower cost in many instances than most alternatives, including large central-station, coal-fired, steam-electric power plants with fuel gas desulphurization, nuclear power plants, and hydroelectricity power plants. BIG/GT technologies offer environmental benefits as well, including the potential for zero net carbon dioxide emissions, if the biomass feedstock is grown renewably. (author). 77 refs., 9 figs., 16 tabs

  17. Potential of the HTGR hydrogen cogeneration system in Japan

    International Nuclear Information System (INIS)

    Nishihara, Tetsuo; Mouri, Tomoaki; Kunitomi, Kazuhiko

    2007-01-01

    A high temperature gas cooled reactor (HTGR) is one of the next generation nuclear systems. The HTGR hydrogen cogeneration system can produce not only electricity but also hydrogen. Then it has a potential to supply massive low-cost hydrogen without greenhouse gas emission for the future hydrogen society. Japan Atomic Energy Agency (JAEA) has been carried out the design study of the HTGR hydrogen cogeneration system (GTHTR300C). The thermal power of the reactor is 600 MW. The hydrogen production plant utilizes 370 MW and can supply 52,000 m 3 /h (0.4 Bm 3 /y) of hydrogen. Present industrial hydrogen production capacity in Japan is about 18 Bm 3 /y and it will decrease by 15 Bm 3 /y in 2030 due to the aging facilities. On the other hand, the hydrogen demand for fuel cell vehicle (FCV) in 2030 is estimated at 15 Bm 3 /y at a maximum. Since the hydrogen supply may be short after 2030, the additional hydrogen should be produced by clean hydrogen process to reduce greenhouse gas emission. This hydrogen shortage is a potential market for the GTHTR300C. The hydrogen production cost of GTHTR300C is estimated at 20.5 JPY/Nm 3 which has an economic competitiveness against other industrial hydrogen production processes. 38 units of the GTHTR300C can supply a half of this shortage which accounts for the 33% of hydrogen demand for FCV in 2100. According to the increase of hydrogen demand, the GTHTR300C should be constructed after 2030. (author)

  18. 1992 National census for district heating, cooling and cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-01

    District energy systems are a major part of the energy use and delivery infrastructure of the United States. With nearly 6,000 operating systems currently in place, district energy represents approximately 800 billion BTU per hour of installed thermal production capacity, and provides over 1.1 quadrillion BTU of energy annually -- about 1.3% of all energy used in the US each year. Delivered through more that 20,000 miles of pipe, this energy is used to heat and cool almost 12 billion square feet of enclosed space in buildings that serve a diverse range of office, education, health care, military, industrial and residential needs. This Census is intended to provide a better understanding of the character and extent of district heating, cooling and cogeneration in the United States. It defines a district energy system as: Any system that provides thermal energy (steam, hot water, or chilled water) for space heating, space cooling, or process uses from a central plant, and that distributes the energy to two or more buildings through a network of pipes. If electricity is produced, the system is a cogenerating facility. The Census was conducted through surveys administered to the memberships of eleven national associations and agencies that collectively represent the great majority of the nation`s district energy system operators. Responses received from these surveys account for about 11% of all district systems in the United States. Data in this report is organized and presented within six user sectors selected to illustrate the significance of district energy in institutional, community and utility settings. Projections estimate the full extent of district energy systems in each sector.

  19. Conceptual design study of a coal gasification combined-cycle powerplant for industrial cogeneration

    Science.gov (United States)

    Bloomfield, H. S.; Nelson, S. G.; Straight, H. F.; Subramaniam, T. K.; Winklepleck, R. G.

    1981-01-01

    A conceptual design study was conducted to assess technical feasibility, environmental characteristics, and economics of coal gasification. The feasibility of a coal gasification combined cycle cogeneration powerplant was examined in response to energy needs and to national policy aimed at decreasing dependence on oil and natural gas. The powerplant provides the steam heating and baseload electrical requirements while serving as a prototype for industrial cogeneration and a modular building block for utility applications. The following topics are discussed: (1) screening of candidate gasification, sulfur removal and power conversion components; (2) definition of a reference system; (3) quantification of plant emissions and waste streams; (4) estimates of capital and operating costs; and (5) a procurement and construction schedule. It is concluded that the proposed powerplant is technically feasible and environmentally superior.

  20. The performance of a temperature cascaded cogeneration system producing steam, cooling and dehumidification

    KAUST Repository

    Myat, Aung

    2013-02-01

    This paper discusses the performance of a temperature-cascaded cogeneration plant (TCCP), equipped with an efficient waste heat recovery system. The TCCP, also called a cogeneration system, produces four types of useful energy-namely, (i) electricity, (ii) steam, (iii) cooling and (iv) dehumidification-by utilizing single fuel source. The TCCP comprises a Capstone C-30 micro-turbine that generates nominal capacity of 26 kW of electricity, a compact and efficient waste heat recovery system and a host of waste-heat-activated devices, namely (i) a steam generator, (ii) an absorption chiller, (iii) an adsorption chiller and (iv) a multi-bed desiccant dehumidifier. The performance analysis was conducted under different operation conditions such as different exhaust gas temperatures. It was observed that energy utilization factor could be as high as 70% while fuel energy saving ratio was found to be 28%. © 2013 Desalination Publications.

  1. A Belgian margarine manufacturer is testing the green cogeneration; Un margarinier belge experimente la cogeneration verte

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2006-01-15

    Aigremont, an independent Belgian margarine manufacturer, is exploiting a 'green cogeneration' unit fueled with vegetal and animal fats. This unit generates 770 kW electrical power which is injected into the power grid and the same quantity of thermal power which is consumed by the fabrication process. Short paper. (J.S.)

  2. Cogeneration: a win-win option for Cadbury Nigeria

    International Nuclear Information System (INIS)

    Dayo, Felix; Bogunjoko, S.B.; Sobanwa, A.C.

    2001-01-01

    Like most developing countries, Nigeria is looking to cogeneration as a sustainable and reliable means of overcoming its present unreliable supply of energy. The article focuses on the efforts of the food company Cadbury Nigeria which uses cogeneration for all its steam and power requirements within its own factory. The Company recently decided to upgrade further by switching from liquid fossil fuels to natural gas. Diagrams show the existing system as well as the systems for cogeneration with natural gas. Some of the obstacles to be overcome to improve the viability of cogeneration in developing countries are listed. It is hoped that the outcome of the COP6 meeting to be held in April 2001 will offer encouragement for cogeneration

  3. Cogeneration: a win-win option for Cadbury Nigeria

    Energy Technology Data Exchange (ETDEWEB)

    Dayo, Felix [Triple ' E' Systems Associates Ltd. (Nigeria); Bogunjoko, S.B.; Sobanwa, A.C. [Cadbury Nigeria plc. (Nigeria)

    2001-02-01

    Like most developing countries, Nigeria is looking to cogeneration as a sustainable and reliable means of overcoming its present unreliable supply of energy. The article focuses on the efforts of the food company Cadbury Nigeria which uses cogeneration for all its steam and power requirements within its own factory. The Company recently decided to upgrade further by switching from liquid fossil fuels to natural gas. Diagrams show the existing system as well as the systems for cogeneration with natural gas. Some of the obstacles to be overcome to improve the viability of cogeneration in developing countries are listed. It is hoped that the outcome of the COP6 meeting to be held in April 2001 will offer encouragement for cogeneration.

  4. An HTR cogeneration system for industrial applications

    International Nuclear Information System (INIS)

    Haverkate, B.R.W.; Heek, A.I. van; Kikstra, J.F.

    2001-01-01

    Because of its favourable characteristics of safety and simplicity the high-temperature reactor (HTR) could become a competitive heat source for a cogeneration unit. The Netherlands is a world leading country in the field of cogeneration. As nuclear energy remains an option for the medium and long term in this country, systems for nuclear cogeneration should be explored and developed. Hence, ECN Nuclear Research is developing a conceptual design of an HTR for Combined generation of Heat and Power (CHP) for the industry in and outside the Netherlands. The design of this small CHP-unit for industrial applications is mainly based on a pre-feasibility study in 1996, performed by a joint working group of five Dutch organisations, in which technical feasibility was shown. The concept that was subject of this study, INCOGEN, used a 40 MW thermal pebble bed HTR and produced a maximum amount of electricity plus low temperature heat. The system has been improved to produce industrial quality heat, and has been renamed ACACIA. The output of this installation is 14 MW electricity and 17 tonnes of steam per hour, with a pressure of 10 bar and a temperature of 220 deg. C. The economic characteristics of this installation turned out to be much more favourable using modern data. The research work for this installation is embedded in a programme that has links to the major HTR projects in the world. Accordingly ECN participates in several IAEA Co-ordinated Research Programmes (CRPs). Besides this, ECN is involved in the South African PBMR-project. Finally, ECN participates in the European Concerted Action on Innovative HTR. (author)

  5. Efficient Use of Cogeneration and Fuel Diversification

    Science.gov (United States)

    Kunickis, M.; Balodis, M.; Sarma, U.; Cers, A.; Linkevics, O.

    2015-12-01

    Energy policy of the European Community is implemented by setting various goals in directives and developing support mechanisms to achieve them. However, very often these policies and legislation come into contradiction with each other, for example Directive 2009/28/EC on the promotion of the use of energy from renewable sources and Directive 2012/27/EU on energy efficiency, repealing Directive 2004/8/EC on the promotion of cogeneration based on a useful heat demand. In this paper, the authors attempt to assess the potential conflicts between policy political objectives to increase the share of high-efficiency co-generation and renewable energy sources (RES), based on the example of Riga district heating system (DHS). If a new heat source using biomass is built on the right bank of Riga DHS to increase the share of RES, the society could overpay for additional heat production capacities, such as a decrease in the loading of existing generating units, thereby contributing to an inefficient use of existing capacity. As a result, the following negative consequences may arise: 1) a decrease in primary energy savings (PES) from high-efficiency cogeneration in Riga DHS, 2) an increase in greenhouse gas (GHG) emissions in the Baltic region, 3) the worsening security situation of electricity supply in the Latvian power system, 4) an increase in the electricity market price in the Lithuanian and Latvian price areas of Nord Pool power exchange. Within the framework of the research, calculations of PES and GHG emission volumes have been performed for the existing situation and for the situation with heat source, using biomass. The effect of construction of biomass heat source on power capacity balances and Nord Pool electricity prices has been evaluated.

  6. Cogeneration: Effects of environmental laws and regulations

    International Nuclear Information System (INIS)

    Dean, J.E.

    1994-01-01

    The new list of environmental regulations caused by the 1990 Clean Air Act Amendments and the expected effects of other environmental and related regulation on American industry is truly staggering. The author's brief overview is limited to the effects on utility customer power generation. In his opinion, the regulations favor the use of clean burning waste materials to generate steam and electricity. The environmental requirements for all industry are expected to tighten significantly. Some of the issues of interest are: timing; clean burning power generation; future projected issues (5 years or more); waste power cogeneration; and Internal Revenue guidelines

  7. Allocating resources and products in multi-hybrid multi-cogeneration: What fractions of heat and power are renewable in hybrid fossil-solar CHP?

    International Nuclear Information System (INIS)

    Beretta, Gian Paolo; Iora, Paolo; Ghoniem, Ahmed F.

    2014-01-01

    A general method for the allocation of resources and products in multi-resource/multi-product facilities is developed with particular reference to the important two-resource/two-product case of hybrid fossil and solar/heat and power cogeneration. For a realistic case study, we show how the method allows to assess what fractions of the power and heat should be considered as produced from the solar resource and hence identified as renewable. In the present scenario where the hybridization of fossil power plants by solar-integration is gaining increasing attention, such assessment is of great importance in the fair and balanced development of local energy policies based on granting incentives to renewables resources. The paper extends to the case of two-resource/two-product hybrid cogeneration, as well as to general multi-resource/multi-generation, three of the allocation methods already available for single-resource/two-product cogeneration and for two-resource/single-product hybrid facilities, namely, the ExRR (Exergy-based Reversible-Reference) method, the SRSPR (Single Resource Separate Production Reference) method, and the STALPR (Self-Tuned-Average-Local-Productions-Reference) method. For the case study considered we show that, unless the SRSPR reference efficiencies are constantly updated, the differences between the STALPR and SRSPR methods become important as hybrid and cogeneration plants take up large shares of the local energy production portfolio. - Highlights: • How much of the heat and power in hybrid solar-fossil cogeneration are renewable? • We define and compare three allocation methods for hybrid cogeneration. • Classical and exergy allocation are based on prescribed reference efficiencies. • Adaptive allocation is based on the actual average efficiencies in the local area. • Differences among methods grow as hybrid CHP (heat and power cogeneration) gains large market fractions

  8. Energy and cost savings results for advanced technology systems from the Cogeneration Technology Alternatives Study /CTAS/

    Science.gov (United States)

    Sagerman, G. D.; Barna, G. J.; Burns, R. K.

    1979-01-01

    The Cogeneration Technology Alternatives Study (CTAS), a program undertaken to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the 1985-2000 time period, is described, and preliminary results are presented. Two cogeneration options are included in the analysis: a topping application, in which fuel is input to the energy conversion system which generates electricity and waste heat from the conversion system is used to provide heat to the process, and a bottoming application, in which fuel is burned to provide high temperature process heat and waste heat from the process is used as thermal input to the energy conversion system which generates energy. Steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics are examined. Expected plant level energy savings, annual energy cost savings, and other results of the economic analysis are given, and the sensitivity of these results to the assumptions concerning fuel prices, price of purchased electricity and the potential effects of regional energy use characteristics is discussed.

  9. High temperature cogeneration with thermionic burners

    Science.gov (United States)

    Fitzpatrick, G. O.; Britt, E. J.; Dick, R. S.

    The thermionic cogeneration combustor was conceived to meet industrial requirements for high-temperature direct heat, typically in the form of gas at temperatures from 800 to 1900 K, while at the same time supplying electricity. The thermionic combustor is entirely self-contained, with heat from the combustion region absorbed by the emitters of thermionic converters to be converted to electric power and the high-temperature reject heat from the converters used to preheat the air used for combustion. Depending on the temperature of the process gas produced, energy savings of around 10% with respect to that used to produce the same amount of electricity and heat without cogeneration are possible with present technology, and savings of up to 20% may be possible with advanced converters. Possible thermionic combustor designs currently under investigation include a configuration in which heat is collected by heat pipes lining the periphery of the combustion region, and a fire-tube converter in which combustion occurs within the cylindrical emitter of each converter. Preliminary component tests of these designs have been encouraging.

  10. Transposition of the EU cogeneration directive: A vision for Portugal

    International Nuclear Information System (INIS)

    Moreira, Nuno Afonso; Monteiro, Eliseu; Ferreira, Sergio

    2007-01-01

    The potential for new, small-scale and micro-cogeneration installations in Portugal is very considerable due to the number of potential host buildings. In this work, we discuss the legal framework of the Portuguese energy market, and some modifications to accommodate the Directive, 2004/8/EC are stressed. A practical case of cogeneration is also presented, showing the application of the Annex III (b) and (c) of the Cogeneration Directive. The practical case presented shows that micro CHP can be considered highly efficient, with parameters calculated with the Directive rules. Two main improvements in Portugal's energy policy are important: improvement on the permission to access grid system and improvement on support mechanisms indexing it to PES. The Cogeneration Directive transposition is an excellent opportunity to induce a less restrictive framework for the installation of new cogeneration systems, reducing the technological barriers, namely allowing medium-voltage connection with the grid, and improving the revenues provided from these small cogeneration systems. These modifications can improve significantly the number of potential hosts for small-scale cogeneration systems. (author)

  11. Community Design Parameters and the Performance of Residential Cogeneration Systems

    Directory of Open Access Journals (Sweden)

    Hazem Rashed-Ali

    2012-11-01

    Full Text Available The integration of cogeneration systems in residential and mixed-use communities has the potential of reducing their energy demand and harmful emissions and can thus play asignificant role in increasing their environmental sustainability. This study investigated the impact of selected planning and architectural design parameters on the environmental and economic performances of centralized cogeneration systems integrated into residential communities in U.S.cold climates. Parameters investigated include: 1 density, 2 use mix, 3 street configuration, 4 housing typology, 5 envelope and building systems’ efficiencies, and 6 passive solar energyutilization. The study integrated several simulation tools into a procedure to assess the impact of each design parameter on the cogeneration system performance. This assessment procedure included: developing a base-line model representing typical design characteristics of U.S. residential communities; assessing the cogeneration system’s performance within this model using three performance indicators: percentage of reduction in primary energy use, percentage of reduction in CO2 emissions; and internal rate of return; assessing the impact of each parameter on the system performance through developing 46 design variations of the base-line model representing potential changes in each parameter and calculating the three indicators for each variation; and finally, using a multi-attribute decision analysis methodology to evaluate the relative impact of each parameter on the cogeneration system performance. The study results show that planning parameters had a higher impact on the cogeneration system performance than architectural ones. Also, a significant correlation was found between design characteristics identified as favorable for the cogeneration system performance and those of sustainable residential communities. These include high densities, high use mix, interconnected street networks, and mixing of

  12. Cogeneration Technology Alternatives Study (CTAS). Volume 3: Industrial processes

    Science.gov (United States)

    Palmer, W. B.; Gerlaugh, H. E.; Priestley, R. R.

    1980-01-01

    Cogenerating electric power and process heat in single energy conversion systems rather than separately in utility plants and in process boilers is examined in terms of cost savings. The use of various advanced energy conversion systems are examined and compared with each other and with current technology systems for their savings in fuel energy, costs, and emissions in individual plants and on a national level. About fifty industrial processes from the target energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. An attempt was made to use consistent assumptions and a consistent set of ground rules specified by NASA for determining performance and cost. Data and narrative descriptions of the industrial processes are given.

  13. Bio-mass utilization in high pressure cogeneration boiler

    Science.gov (United States)

    Koundinya, Sandeep; Maria Ambrose Raj, Y.; Sreeram, K.; Divakar Shetty A., S.

    2017-07-01

    Coal is widely used all over the world in almost all power plants. The dependence on coal has increased enormously as the demand for electricity has reached its peak. Coal being a non-renewable source is depleting fast. We being the engineers, it's our duty to conserve the natural resources and optimize the coal consumption. In this project, we have tried to optimize the bio-mass utilization in high pressure cogeneration boiler. The project was carried in Seshasayee Paper and Boards Limited, erode related to Boiler No:10 operating at steam pressure of 105 kscg and temperature of 510°C. Available bio-mass fuels in and around the mill premises are bagasse, bagasse pith, cane trash and chipper dust. In this project, we have found out the coal equivalent replacement by the above bio-mass fuel(s) to facilitate deciding on the optimized quantity of coal that can be replaced by biomass without modifying the existing design of the plant. The dominant fuel (coal) which could be displaced with the substitute biomass fuel had been individually (biomass) analyzed.

  14. Selected aspects of cogeneration technology in distributed energy applications

    Science.gov (United States)

    Zuchora, Konrad

    2017-08-01

    The paper presents an opinion on the use of distributed cogeneration technologies in the power industry. It offers worked out experiences and views on the idea of using renewable energy sources in the conventional power industry. The effects of the work done are analysed arguments concerning the use of cogeneration and renewable energy sources in the micropower industry, and developed ways of the functioning of the distributed energy generation system. The publication presents conclusions and simulation results of the criterial work of a micropower system containing in its structure renewable energy sources and a cogeneration unit.

  15. Analysis of the natural gas utilization for energy cogeneration in a sugar and alcohol plant; Analise da utilizacao de gas natural para cogeracao de energia em uma usina de acucar e alcool

    Energy Technology Data Exchange (ETDEWEB)

    Uchoa, Thales B.; Campitelli, Flavio M.; Mashiba, Marcos H.S.; Dib, Fernando H.; Maia, Cassio R.M.; Ramos, Ricardo A.V. [UNESP, Ilha Solteira, SP (Brazil). Faculdade de Engenharia. Dept. de Engenharia Mecanica]. E-mails: thales@dem.feis.unesp.br; fmcampitelli@dem.feis.unesp.br; mashiba@dem.feis.unesp.br; fhdib@aluno.feis.unesp.br; cassio@dem.feis.unesp.br; ramos@dem.feis.unesp.br

    2006-07-01

    This article analyses the possibility of using natural gas as complementary fuel in sugar cane and alcohol plants, nearby the gas pipeline, for increasing the energy quantity for commercialization, and also for allowing the operation during the whole year. A thermodynamical study is done and the technical and economic viability is performed for various configurations involving the modification of the traditional plants existent in that plant for allowing the combined use of gas.

  16. EFFECTS OF IMPLEMENTATION OF CO-GENERATION IN THE DISTRICT HEATING SYSTEM OF THE FACULTY OF MECHANICAL ENGINEERING IN NIŠ

    Directory of Open Access Journals (Sweden)

    Mladen M Stojiljković

    2010-01-01

    Full Text Available Implementation of co-generation of thermal and electrical energy in district heating systems often results with higher overall energy efficiency of the systems, primary energy savings and environmental benefits. Financial results depend on number of parameters, some of which are very difficult to predict. After introduction of feed-in tariffs for generation of electrical energy in Serbia, better conditions for implementation of co-generation are created, although in district heating systems barriers are still present. In this paper, possibilities and effects of implementation of natural gas fired co-generation engines are examined and presented for the boiler house that is a part of the district heating system owned and operated by the Faculty of Mechanical Engineering in Niš. At the moment, in this boiler house only thermal energy is produced. The boilers are natural gas fired and often operate in low part load regimes. The plant is working only during the heating season. For estimation of effects of implementation of co-generation, referent values are taken from literature or are based on the results of measurements performed on site. Results are presented in the form of primary energy savings and greenhouse gasses emission reduction potentials. Financial aspects are also considered and triangle of costs is shown.

  17. Applying a non-intrusive energy-management system to economic dispatch for a cogeneration system and power utility

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hsueh-Hsien [Dept. of Electrical Engineering, Chung Yuan Christian University, Taoyuan (China); Dept. of Electronic Engineering, Jin Wen University of Science and Technology, Taipei (China); Yang, Hong-Tzer [Dept. of Electrical Engineering, National Cheng Kung University, Tainan (China)

    2009-11-15

    Non-intrusive energy-management (NIEM) techniques are based on energy signatures. While such approaches lack transient energy signatures, the reliability and accuracy of recognition results cannot be determined. By using neural networks (NNs) in combination with turn-on transient energy analysis, this study attempts to identify load demands and improve recognition accuracy of NIEM results. Case studies are presented that apply various methods to compare training algorithms and classifiers in terms of artificial neural networks (ANN) due to various factors that determine whether a network is being used for pattern recognition. Additionally, in combination with electromagnetic transient program (EMTP) simulations, calculating the turn-on transient energy facilitate load can lead to identification and a significant improvement in the accuracy of NIEM results. Analysis results indicate that an NIEM system can effectively manage energy demands within economic dispatch for a cogeneration system and power utility. Additionally, a new method based on genetic algorithms (GAs) is used to develop a novel operational strategy of economic dispatch for a cogeneration system in a regulated market and approach the global optimum with typical environmental constraints for a cogeneration plant. Economic dispatch results indicate that the NIEM system based on energy demands can estimate accurately the energy contribution from the cogeneration system and power utility, and further reduce air pollution. Moreover, applying the NIEM system for economic dispatch can markedly reduce computational time and power costs. (author)

  18. Cogeneration: A new opportunity for energy production market; La cogenerazione: Una nuova opportunita` per il mercato della produzione di energia

    Energy Technology Data Exchange (ETDEWEB)

    Minghetti, E. [ENEA, Centro Ricerche Casaccia, Rome (Italy)

    1997-03-01

    Cogeneration or Combined Heat and Power (CHP) is an advantageous technique based on the simultaneous utilisation of electricity and heat produced. For this purpose existing energetic technologies are used. Cogeneration is based on the thermodynamics principle that producing electricity by combustion process means, at the same time, producing waste heat that can be useful utilised. Three main advantages can be lay out in a cogeneration plant: 1. High efficiency (the global efficiency is often around 80-90%). 2. Economic profit (pay back time is usually not longer than 2-4 years). 3. Low pollutant emissions (as a consequence of the high efficiency less fuel is burned for generating the same quantity of electricity). In this report are analysed various aspects of cogeneration (technical and economical) and the conditions influencing is development. Some figures on the european and national situation are also given. Finally are presented the research and development activities carried out by Italian National Agency for new Technology Energy and the Environment Energy Department to improve the efficiency and the competitiveness of this technology.

  19. Vacuum evaporation treatment of digestate: full exploitation of cogeneration heat to process the whole digestate production.

    Science.gov (United States)

    Guercini, S; Castelli, G; Rumor, C

    2014-01-01

    Vacuum evaporation represents an interesting and innovative solution for managing animal waste surpluses in areas with high livestock density. To reduce operational costs, a key factor is the availability of an inexpensive source of heat, such as that coming from an anaerobic digestion (AD) plant. The aim of this study was to test vacuum evaporation for the treatment of cattle slurry digestate focusing on heat exploitation. Tests were performed with a pilot plant fed with the digestate from a full-scale AD plant. The results were used to evaluate if and how cogeneration heat can support both the AD plant and the subsequent evaporation of the whole daily digestate production in a full-scale plant. The concentrate obtained (12% total solids) represents 40-50% of the influent. The heat requirement is 0.44 kWh/kg condensate. Heat power availability exceeding the needs of the digestor ranges from 325 (in winter) to 585 kW (in summer) versus the 382 kW required for processing the whole digestate production. To by-pass fluctuations, we propose to use the heat coming from the cogenerator directly in the evaporator, tempering the digestor with the latent heat of distillation vapor.

  20. Urban Integrated Industrial Cogeneration Systems Analysis. Phase II final report

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    Through the Urban Integrated Industrial Cogeneration Systems Analysis (UIICSA), the City of Chicago embarked upon an ambitious effort to identify the measure the overall industrial cogeneration market in the city and to evaluate in detail the most promising market opportunities. This report discusses the background of the work completed during Phase II of the UIICSA and presents the results of economic feasibility studies conducted for three potential cogeneration sites in Chicago. Phase II focused on the feasibility of cogeneration at the three most promising sites: the Stockyards and Calumet industrial areas, and the Ford City commercial/industrial complex. Each feasibility case study considered the energy load requirements of the existing facilities at the site and the potential for attracting and serving new growth in the area. Alternative fuels and technologies, and ownership and financing options were also incorporated into the case studies. Finally, site specific considerations such as development incentives, zoning and building code restrictions and environmental requirements were investigated.

  1. Thermodynamic study of residual heat from a high temperature nuclear reactor to analyze its viability in cogeneration processes

    International Nuclear Information System (INIS)

    Santillan R, A.; Valle H, J.; Escalante, J. A.

    2015-09-01

    In this paper the thermodynamic study of a nuclear power plant of high temperature at gas turbine (GTHTR300) is presented for estimating the exploitable waste heat in a process of desalination of seawater. One of the most studied and viable sustainable energy for the production of electricity, without the emission of greenhouse gases, is the nuclear energy. The fourth generation nuclear power plants have greater advantages than those currently installed plants; these advantages have to do with security, increased efficiencies and feasibility to be coupled to electrical cogeneration processes. In this paper the thermodynamic study of a nuclear power plant type GTHTR300 is realized, which is selected by greater efficiencies and have optimal conditions for use in electrical cogeneration processes due to high operating temperatures, which are between 700 and 950 degrees Celsius. The aim of the study is to determine the heat losses and the work done at each stage of the system, determining where they are the greatest losses and analyzing in that processes can be taken advantage. Based on the study was appointed that most of the energy losses are in form of heat in the coolers and usually this is emitted into the atmosphere without being used. From the results a process of desalination of seawater as electrical cogeneration process is proposed. This paper contains a brief description of the operation of the nuclear power plant, focusing on operation conditions and thermodynamic characteristics for the implementation of electrical cogeneration process, a thermodynamic analysis based on mass and energy balance was developed. The results allow quantifying the losses of thermal energy and determining the optimal section for coupling of the reactor with the desalination process, seeking to have a great overall efficiency. (Author)

  2. Klickitat Cogeneration Project: Final environmental assessment

    International Nuclear Information System (INIS)

    1994-09-01

    To meet BPA's contractual obligation to supply electrical power to its customers, BPA proposes to acquire power generated by Klickitat Cogeneration Project. BPA has prepared an environmental assessment evaluating the proposed project. Based on the EA analysis, BPA's proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 for the following reasons: (1)it will not have a significant impact land use, upland vegetation, wetlands, water quality, geology, soils, public health and safety, visual quality, historical and cultural resources, recreation and socioeconomics, and (2) impacts to fisheries, wildlife resources, air quality, and noise will be temporary, minor, or sufficiently offset by mitigation. Therefore, the preparation of an environmental impact statement is not required and BPA is issuing this FONSI (Finding of No Significant Impact)

  3. Klickitat Cogeneration Project : Final Environmental Assessment.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration; Klickitat Energy Partners

    1994-09-01

    To meet BPA`s contractual obligation to supply electrical power to its customers, BPA proposes to acquire power generated by Klickitat Cogeneration Project. BPA has prepared an environmental assessment evaluating the proposed project. Based on the EA analysis, BPA`s proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 for the following reasons: (1)it will not have a significant impact land use, upland vegetation, wetlands, water quality, geology, soils, public health and safety, visual quality, historical and cultural resources, recreation and socioeconomics, and (2) impacts to fisheries, wildlife resources, air quality, and noise will be temporary, minor, or sufficiently offset by mitigation. Therefore, the preparation of an environmental impact statement is not required and BPA is issuing this FONSI (Finding of No Significant Impact).

  4. Cogeneration, renewables and reducing greenhouse gas emissions

    International Nuclear Information System (INIS)

    Naughten, B.; Dlugosz, J.

    1996-01-01

    The MENSA model is used to assess the potential role of cogeneration and selected new renewable energy technologies in cost-effectively reducing Greenhouse gas emissions. The model framework for analyzing these issues is introduced, together with an account of relevant aspects of its application. In the discussion of selected new renewable energy technologies, it is shown how microeconomic reform may encourage these technologies and fuels, and thereby reduce sector wide carbon dioxide emissions. Policy scenarios modelled are described and the simulation results are presented. Certain interventions in microeconomic reform may result in economic benefits while also reducing emissions: no regrets' opportunities. Some renewable energy technologies are also shown to be cost-effective in the event that targets and timetables for reducing Greenhouse gas emissions are imposed. However, ad hoc interventions in support of particular renewables options are unlikely to be consistent with a least cost approach to achieving environmental objectives. (author). 5 tabs., 5 figs., 21 refs

  5. Cogeneration steam turbines from Siemens: New solutions

    Science.gov (United States)

    Kasilov, V. F.; Kholodkov, S. V.

    2017-03-01

    The Enhanced Platform system intended for the design and manufacture of Siemens AG turbines is presented. It combines organizational and production measures allowing the production of various types of steam-turbine units with a power of up to 250 MWel from standard components. The Enhanced Platform designs feature higher efficiency, improved reliability, better flexibility, longer overhaul intervals, and lower production costs. The design features of SST-700 and SST-900 steam turbines are outlined. The SST-700 turbine is used in backpressure steam-turbine units (STU) or as a high-pressure cylinder in a two-cylinder condensing turbine with steam reheat. The design of an SST-700 single-cylinder turbine with a casing without horizontal split featuring better flexibility of the turbine unit is presented. An SST-900 turbine can be used as a combined IP and LP cylinder (IPLPC) in steam-turbine or combined-cycle power units with steam reheat. The arrangements of a turbine unit based on a combination of SST-700 and SST-900 turbines or SST-500 and SST-800 turbines are presented. Examples of this combination include, respectively, PGU-410 combinedcycle units (CCU) with a condensing turbine and PGU-420 CCUs with a cogeneration turbine. The main equipment items of a PGU-410 CCU comprise an SGT5-4000F gas-turbine unit (GTU) and STU consisting of SST-700 and SST-900RH steam turbines. The steam-turbine section of a PGU-420 cogeneration power unit has a single-shaft turbine unit with two SST-800 turbines and one SST-500 turbine giving a power output of N el. STU = 150 MW under condensing conditions.

  6. The role of cogeneration systems in sustainability of energy

    International Nuclear Information System (INIS)

    Çakir, Uğur; Çomakli, Kemal; Yüksel, Fikret

    2012-01-01

    Highlights: ► Energy source on the world is tending to run out day by day while the energy need of humanity is increasing simultaneously. ► There are two ways to overcome this problem; one of them is renewable energy sources like solar or wind energy systems. ► The other way is like cogeneration systems. ► Cogeneration system is one of the ways to save the energy and use the energy efficiently. ► A case study is made for a hospital to present the sustainability aspects of cogeneration systems. - Abstract: Cogeneration system (CHP) is one of the ways to save the energy and use the energy efficiently. When compared to separate fossil-fired generation of heat and electricity, CHP may result in a consistent energy conservation (usually ranging from 10% to 30%) while the avoided CO 2 emissions are, as a first approximation, similar to the amount of energy saving. In terms of sustainability, one of the primary considerations is energy efficiency. Sustainable energy is considered as a kind of energy which is renewable and continuous, meaning that the use of such energy can potentially be kept up well into the future without causing harmful repercussions for future generations. In this study, environmental benefits and sustainability aspects of cogeneration systems and importance of those systems to the use of sustainable energy are underlined. To support this idea, first we have referred some scientific studies previously made on cogeneration systems and then we have used our own case study. The case study made on gas engined cogeneration system was applied for a hospital to show the sustainability aspects of cogeneration systems.

  7. Cogeneration and taxation in a liberalised Nordic power market

    International Nuclear Information System (INIS)

    Jess Olsen, O.; Munksgaard, J.

    1997-01-01

    This report is about the impact of the liberalisation of the Nordic power market on cogeneration of heat and power. Special attention is given to the effects on competition of the entirely different tax regimes in the Nordic countries. Some of the main questions answered in this study are: Which cogeneration technologies are able to compete on a liberalised power market? What are the consequences of different tax structures in the four countries for cross-border competition? Which principles should be applied if a common Nordic tax structure is to be developed? The following countries are included in the study: Denmark, Finland, Norway and Sweden. Today, cogeneration provides a larger contribution to the energy supply in the Nordic countries than elsewhere in the world. Our analysis demonstrates that most cogeneration technologies can compete with the power-only technologies. This is the case with respect to both long- and short-term marginal costs. The main exception is the very expensive straw-fired cogeneration technology. The analysis is extended to include the effects of the existing tax regimes (in 1996) in Denmark, Finland and Sweden as well as of the combines energy/CO 2 -tax that was proposed in 1992 by the European Commission. Each of the four tax regimes preserve the competitiveness of cogeneration within its own regime, i.e. if a given cogeneration technology is competitive without taxes it will remain so in a closed market when either Danish, Finnish, Swedish or European taxes are added. The implication of this is that the same cogeneration technology will be exposed to very different conditions in an open power market with cross-border competition, if the present tax regimes in the Nordic countries are allowed to continue. (EG) Also published in Danish. 15 refs

  8. Cogeneration – development and prospect in Polish energy sector

    Directory of Open Access Journals (Sweden)

    Matuszewska Dominika

    2017-01-01

    Full Text Available Next 10-15 years are crucial for condition of Polish energy sector in light of challenges arising mainly from increasing demand for electric energy, need of reducing greenhouse gases emissions and shutdowns of old units. In this situation cogeneration can be one of the most rational way to meet those circumstances. This paper analyzes present development of cogeneration in Poland and its prospect for future.

  9. Sustainability assessment of cogeneration sector development in Croatia

    International Nuclear Information System (INIS)

    Liposcak, Marko; Afgan, Naim H.; Duic, Neven; Graca Carvalho, Maria da

    2006-01-01

    The effective and rational energy generation and supply is one of the main presumptions of sustainable development. Combined heat and power production, or co-generation, has clear environmental advantages by increasing energy efficiency and decreasing carbon emissions. However, higher investment cost and more complicated design and maintenance sometimes-present disadvantages from the economical viability point of view. As in the case of most of economies in transition in Central and Eastern Europe, Croatia has a strong but not very efficient co-generation sector, delivering 12% of the final energy consumption. District heating systems in the country's capital Zagreb and in city of Osijek represent the large share of the overall co-generation capacity. Besides district heating, co-generation in industry sector is also relatively well developed. The paper presents an attempt to assess the sustainability of Croatian co-generation sector future development. The sustainability assessment requires multi-criteria assessment of specific scenarios to be taken into consideration. In this respect three scenarios of Croatian co-generation sector future development are taken into consideration and for each of them environmental, social and economic sustainability indicators are defined and calculated. The assessment of complex relationships between environmental, social and economic aspects of the system is based on the multi-criteria decision-making procedure. The sustainability assessment is based on the General Sustainability Index rating for different cases reflecting different criteria and their priority. The method of sustainability assessment is applied to the Croatian co-generation sector contributing to the evaluation of different strategies and definition of a foundation for policy related to the sustainable future cogeneration sector development

  10. Modelling of a chemisorption refrigeration and power cogeneration system

    International Nuclear Information System (INIS)

    Bao, Huashan; Wang, Yaodong; Roskilly, Anthony Paul

    2014-01-01

    Highlights: • An adsorption cogeneration was proposed and simulated for cooling and electricity. • A dynamic model was built and studied to demonstrate the variability of the system. • A dynamic model included the complex coupling of thermodynamic and chemical kinetic. • Mutual constrains between main components and optimisation methods were discussed. • The highest theoretical COP and exergy efficiency of cogeneration is 0.57 and 0.62. - Abstract: The present work for the first time explores the possibility of a small-scale cogeneration unit by combining solid–gas chemisorption refrigeration cycle and a scroll expander. The innovation in this work is the capability of producing refrigeration and electricity continuously and simultaneously without aggravating the energy scarcity and environmental impact. Individual modelling for each component, which has been validated by experimental data, was firstly investigated in order to identify the proper operation condition for the cogeneration mode achieving 1000 W power output. Subsequently, with the integrated modelling of two components the cogeneration performance was studied to demonstrate the viability of this concept. However, because of the mutual constraint between the chemisorption and the expansion when they link in series, the power output of the cogeneration mode was only around one third of the original expectation under the same condition identified in the individual modelling. Methods of improving the global performance including the selection of reactive mediums were also discussed and would be of referable value for the future practical investigation

  11. Inquiry on the valorisation of heat produced by methanization with co-generation in France. Energy and territory: Valorisation of heat produced by methanization

    International Nuclear Information System (INIS)

    Bazin, Florian; David, Laura; Heuraux, Thalie; Jeziorny, Thibaud; Massazza, Michael; Mosse, Noemie; Nguyen Dai, Kim Yen; Pruvost, Paul; Regimbart, Amelie; Rogee, Pierre-Emmanuel; Roy, Samuel; Segret, Emilien

    2014-01-01

    A leaflet first proposes graphs which illustrate the valorisation of heat produced by methanization with co-generation in France: material and methods, farm characterisation, plant sources, valorisation modes. The second document proposes detailed and discussed presentations of the various involved processes. Contributions address methanization as a whole, valorisation of heat produced by co-generation through heating of agricultural and domestic buildings or through digestate dehydration, digestate hygienisation, and other types of valorisation such as fodder drying, cereal drying, wood drying, compost drying, fabrication of rape seed, greenhouse crops, cultures of micro algae, and mushroom farming

  12. Fiscal 1999 report on basic research for promotion of joint implementation programs. Heat and power plant reconstruction project for Yuzhmash Company co-generating plant, Donepropetrovsk City, the Ukraine; 1999 nendo Donepropetrovsk shi Yuzhmansh sha Heat and Power Plant Reconstruction Project chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This project complies with the COP3 (Third Session of the Conference of the Parties to the United Nations Framework Convention on Climate Change) protocol. To be newly installed are three gas turbine power generators (rating: 26MW, main fuel: natural gas), three waste heat recovery boilers (additionally fired boilers, 2-pressure natural circulation type), and one 40MW water circulation type mixed pressure steam turbine power generator (including a bleeder for co-generation). Greenhouse gases will be reduced by 242,424 tons/year in terms of CO2. The project will cost 9-billion yen in total, with improvement on cost performance expected to be 37,000 yen/ton/year in terms of CO2 and 1,500 yen/ton/25 years. Profitability is assessed using EIRR (economic internal rate of return) when the exchange rate is set at 4.91 UHA/US dollar (as of February 2000). Provided that the emission trading rate in US dollar/ton in CO2 is 0.0, 5.00, 14.0, or 60.00, the economic rate of return will be 7.363, 8.112, 9.399, or 15.155%, respectively. To realize an internal rate of return of 15% which the project wants to achieve, the emission trading rate needs to be 60 US dollars/ton in CO2 or higher. (NEDO)

  13. Modification of Musil-Marecki costs division method applied to cogeneration of heat power (CHP) systems with extraction-condensing turbo-sets

    International Nuclear Information System (INIS)

    Szafran, R.

    1992-01-01

    The method of costs division in cogeneration of heat and power is presented. This is a modification of the ''economic costs division''called Musil-Marecki method applied to heat and power plants with extraction-condensing turbo-sets. Calculated examples show the place of this method on the background of other costs division methods. (author) 5 refs, 4 figs

  14. The Design and Commissioning of a Micro-cogeneration Testing Facility

    Science.gov (United States)

    Boucher, Evan

    The simultaneous production of heat and electricity onsite to serve residential loads can potentially yield a reduction in operating costs, primary energy use and related emissions over traditional technologies which meet these loads separately. Proper sizing and operation of units along with their required buffering and auxiliary systems are critical to the realization of both economical and environmental performance objectives. Further research is required to develop strategies to integrate micro-cogeneration technologies into Canadian residences as issues related to device type, capacity, design of balance of plant components, and controls remain largely unresolved. Building performance simulation is a highly flexible, and time-efficient method to systematically explore and evaluate different design options; however, the validity of the conclusions resulting from simulation based studies are dependent on the accuracy and reliability of the models employed. In order to support ongoing research relating to micro-cogeneration technologies through simulation based activities, a facility capable of subjecting units to controlled electrical and thermal loading was designed and commissioned to collect performance data suitable for device-specific model calibration. The facility can also be configured to provide realistic thermal and electrical loading to complete micro-cogeneration systems including thermal storage and auxiliary heating to evaluate the performance of complete systems. It provides a platform to experimentally investigate appropriate configurations to integrate units into residences through variations in the balance of plant components and control strategies. This thesis describes the design of the facility including its hardware, instrumentation, data acquisition and controls systems. Also described are experiments that were conducted during the commissioning phase to assess system level performance, to identify and correct hardware integration issues

  15. Supercritical biodiesel production and power cogeneration: technical and economic feasibilities.

    Science.gov (United States)

    Deshpande, A; Anitescu, G; Rice, P A; Tavlarides, L L

    2010-03-01

    An integrated supercritical fluid technology with power cogeneration to produce biodiesel fuels, with no need for the costly separations involved with the conventional technology, is proposed, documented for technical and economic feasibility, and preliminarily designed. The core of the integrated system consists of the transesterification of various triglyceride sources (e.g., vegetable oils and animal fats) with supercritical methanol/ethanol. Part of the reaction products can be combusted by a diesel power generator integrated in the system which, in turn, provides the power needed to pressurize the system and the heat of the exhaust gases necessary in the transesterification step. The latter energy demand can also be satisfied by a fired heater, especially for higher plant capacities. Different versions of this system can be implemented based on the main target of the technology: biodiesel production or diesel engine applications, including power generation. The process options considered for biodiesel fuel production estimate break-even processing costs of biodiesel as low as $0.26/gal ($0.07/L) with a diesel power generator and $0.35/gal ($0.09/L) with a fired heater for a plant capacity of 15,000 gal/day (56,775 L/day). Both are significantly lower than the current processing costs of approximately $0.51/gal ($0.13/L) of biodiesel produced by conventional catalytic methods. A retail cost of biodiesel produced by the proposed method is likely to be competitive with the prices of diesel fuels. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  16. Life cycle energy use and GHG emission assessment of coal-based SNG and power cogeneration technology in China

    International Nuclear Information System (INIS)

    Li, Sheng; Gao, Lin; Jin, Hongguang

    2016-01-01

    Highlights: • Life cycle energy use and GHG emissions are assessed for SNG and power cogeneration. • A model based on a Chinese domestic database is developed for evaluation. • Cogeneration shows lower GHG emissions than coal-power pathway. • Cogeneration has lower life cycle energy use than supercritical coal-power pathway. • Cogeneration is a good option to implement China’s clean coal technologies. - Abstract: Life cycle energy use and GHG emissions are assessed for coal-based synthetic natural gas (SNG) and power cogeneration/polygenereation (PG) technology and its competitive alternatives. Four main SNG applications are considered, including electricity generation, steam production, SNG vehicle and battery electric vehicle (BEV). Analyses show that if SNG is produced from a single product plant, the lower limits of its life cycle energy use and GHG emissions can be comparable to the average levels of coal-power and coal-BEV pathways, but are still higher than supercritical and ultra supercritical (USC) coal-power and coal-BEV pathways. If SNG is coproduced from a PG plant, when it is used for power generation, steam production, and driving BEV car, the life cycle energy uses for PG based pathways are typically lower than supercritical coal-power pathways, but are still 1.6–2.4% higher than USC coal-power pathways, and the average life cycle GHG emissions are lower than those of all coal-power pathways including USC units. If SNG is used to drive vehicle car, the life cycle energy use and GHG emissions of PG-SNGV-power pathway are both much higher than all combined coal-BEV and coal-power pathways, due to much higher energy consumption in a SNG driven car than in a BEV car. The coal-based SNG and power cogeneration technology shows comparable or better energy and environmental performances when compared to other coal-based alternatives, and is a good option to implement China’s clean coal technologies.

  17. Electricity Cogenerator from Hydrogen and Biogas

    Science.gov (United States)

    Pinate, W.; Chinnasa, P.; Dangphonthong, D.

    2017-09-01

    This research studied about electricity cogenerator from Hydrogen and Biogas and the factors that cause that effecting Hydrogen from Aluminium which was a cylindrical feature. By using a catalyst was NaOH and CaO, it was reacted in distilled water with percentage of Aluminium: the catalyst (NaOH and CaO) and brought to mix with Biogas afterwards, that have been led to electricity from generator 1 kilowatt. The research outcomes were concentration of solutions that caused amount and percent of maximum Hydrogen was to at 10 % wt and 64.73 % which rate of flowing of constant gas 0.56 litter/minute as temperature 97 degree Celsius. After that led Hydrogen was mixed by Biogas next, conducted to electricity from generator and levelled the voltage of generator at 220 Volt. There after the measure of electricity current and found electricity charge would be constant at 3.1 Ampere. And rate of Biogas flowing and Hydrogen, the result was the generator used Biogas rate of flowing was highest 9 litter/minute and the lowest 7.5 litter/minute, which had rate of flowing around 8.2 litter/minute. Total Biogas was used around 493.2 litter or about 0.493 m3 and Hydrogen had rate of flowing was highest 2.5 litter/minute.

  18. Natural gas purchasing for cogeneration projects

    International Nuclear Information System (INIS)

    Kubacki, J. Jr.

    1992-01-01

    This paper reports on the primary cost component for most gas-fired cogeneration or on-site power projects, cost of natural gas. Often gas comprises 50 to 65% of total project costs over the life of the project. Thus it is very important to focus on natural gas sourcing, pricing, transportation and storage. This important task should not be blindly delegated to a gas supplier. The end user must develop a gas strategy that results in the most cost-effective burnertip price. Long-term natural gas supplies are usually source from the three major producing regions: Mod-Continent, Gulf Coast, and Western Canada. A well-reasoned gas strategy must include: determination of transportation and distribution options from the project site to potential gas sources (including direct interconnection of the project to interstate pipelines); acquisition of competitive gas bids from suppliers in appropriate regions; negotiation of potential discounts from interstate pipelines and local distribution companies (LDCs); fine-tuning project economics by, for example, using storage to maximize transportation load factor; and pricing mechanisms that meet economic parameters of the project. This paper uses a hypothetical project in the Midwest to examine the major factors in devising a cost-effective natural gas sourcing

  19. Optimal planning of gas turbine cogeneration system based on linear programming. Paper no. IGEC-1-ID09

    International Nuclear Information System (INIS)

    Oh, S.-D.; Kwak, H.-Y.

    2005-01-01

    An optimal planning for gas turbine cogeneration system has been studied. The planning problem considered in this study is to determine the optimal configuration of the system equipments and optimal operational policy of the system when the annual energy demands of electric power, heat and cooling are given a priori. The main benefit of the optimal planning is to minimize operational costs and to save energy by efficient energy utilization. A mixed-integer linear programming and the branch and bound algorithm have been adopted to obtain the optimal solution. Both the optimal configuration of the system equipments and the optimal operation policy has been obtained based on annual cost method. The planning method employed here may be applied to the planning problem of the cogeneration plant to any specific building or hotel. (author)

  20. Methodology for the economic evaluation of cogeneration/desalination options: A user's manual

    International Nuclear Information System (INIS)

    1997-01-01

    The Methodology for the Economic Evaluation of Cogeneration/Desalination Options is suitable for economic evaluations and screening analyses of various desalination and energy source options. The methodology, based on the spreadsheet, includes simplified models of several types of nuclear/fossil power plants, nuclear/fossil heat sources, and both distillation and membrane desalination plants. Current cost and performance data have already been incorporated so that the spreadsheet can be quickly adapted to analyze a large variety of options with very little new input data required. The spreadsheet output includes the levelized cost of water and power, breakdowns of cost components, energy consumption and net saleable power for each selected option. Specific power plants can be modeled by adjustment of input data including design power, power cycle parameters and costs

  1. Preliminary study of nuclear power cogeneration system using gas turbine process

    Energy Technology Data Exchange (ETDEWEB)

    Fumizawa, Motoo; Inaba, Yoshitomo; Hishida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Ogawa, Masuro; Ogata, Kann; Yamada, Seiya

    1995-12-01

    The Nuclear power generation plant (NPGP) releases smaller amount of carbon dioxide than the fossil power plant for the generation of the unit electrical power. Thus, the NPGP is expected to contribute resolving the ecological problems. It is important to investigate the nuclear power cogeneration system using gas turbine process from the view point that it is better to produce electricity in high thermal efficiency from the high temperature energy. We carried out, in the current preliminary study, the survey and selection of the candidate cycles, then conducted the evaluation of cycle efficiency, the selection of R and D items to be solved for the decision of the optimum cycle. Following this, we evaluated nuclear heat application for intermediate and low temperature level released from gas turbine process and overall efficiency of cogeneration system. As a result, it was clarified that overall efficiency of the direct regenerative cycle was the highest in low temperature region below 200degC, and that of the direct regenerative inter cooling cycle was the highest in middle and high temperature region. (author).

  2. Performance simulation of a basic combined cycle cogeneration system. Paper no. IGEC-1-ID20

    International Nuclear Information System (INIS)

    Law, B.; Reddy, B.V.

    2005-01-01

    Combined cycle power plants with a gas turbine topping cycle and a steam turbine bottoming cycle are being employed for power generation. It would be advantageous if they are used to produce power and process heat in cogeneration mode, from the same fuel source. The objective of the present work is to analyze and simulate a natural gas fired combined cycle cogeneration (CCC) unit and to investigate the effect of different operating conditions, with the goal of improving the plant performance and efficiency. In the present work, two units are examined, a basic unit and a unit with supplementary firing. The operating conditions investigated include, pressure ratio, gas turbine inlet temperature, component efficiencies and process heat load variation. The preliminary results indicate that a CCC unit should be designed to operate with the highest possible pressure ratio in order to optimize performance. It is established that a CCC unit should employ gas turbines that operate at the maximum allowable temperature. This will optimize the system performance and increase all of the outputs of the system. Supplementary firing is an attractive option for industries with varying process heat load requirements. (author)

  3. Low power cogeneration prototype system; Prototipo de sistema de co-geracao de pequena potencia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Sara M.; Martins, Jose A.S.; Camara, Paulo R.; Cortes, Breno P.; Neves, Elierton E. [Centro de Tecnologias do Gas (CTGAS), Natal, RN (Brazil); F. Filho, Roberto; Campos, Michel F. [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2004-07-01

    The fuels from oil and natural gas play an important role, not only in the sector of primary energy, but also in almost all the other sectors of the economy, due to its imbrication as insum of these. The use of the natural gas will have great expansion in Brazil, motivated for the Government decision to increase the participation of this fuel in the Brazilian energy matrix from 4% to 12% up to 2010. Then, it's so important the investment in new technologies and also the improvement. In order to reach the objective related to increase the consumption of natural gas in the energy matrix, and to propose solutions to attend the electric requirements, of heat and refrigeration, using natural gas as primary power plant, the Center of Gas Technologies; CTGAS, in partnership with PETROBRAS and the Fockink Group, has developed the first modular system of generation and co-generation of energy by natural gas of low power, of easy installation and shipment with the characteristics techniques to take care of to companies or industrial sectors that consummate this band of power. The equipment generates 35 kW/55 kVA of electric energy, 7TR (Ton of Refrigeration) of energy for refrigeration and posses the ability to heat 2200 l/h of water in the temperature of 85 deg C. The equipment will be able to produce electric and thermal energy simultaneously, from an only fuel, the natural gas. The main objective of this work is to present the main phases of development of the archetype, functions techniques of the co-generator and its field of performance in the market of systems for generation and co-generation of energy by natural gas of low power. (author)

  4. Guide to the effective use of cogeneration and fuel cell (Akita Prefecture); Cogeneration nenryo denchi katsuyo guide (Akitaken)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    General cogeneration and fuel cells are separately described in this guidebook. There is a view that a fuel cell is a highly efficient energy system in which both electric power and heat are effectively utilized, and it regards the fuel cell as representative of one of the utilization modes of cogeneration. Following this view, a fuel cell is given a position in parallel with general cogeneration. This guidebook expects that it will be read at private businesses and factories and various public departments within the prefecture where the introduction and utilization of general cogeneration and fuel cells are under study, and describes the procedures to follow when using the energy systems and names the offices to which the readers should refer as need arises. It also expects that people at large in the prefecture who are interested in general cogeneration and fuel cells will be among the readers, and various information is stated for them outlining the energy systems, explaining their merits, and mentioning cases of their application in the past. (NEDO)

  5. Examination on small-sized cogeneration HTGR for developing countries

    International Nuclear Information System (INIS)

    Sakaba, Nariaki; Tachibana, Yukio; Shimakawa, Satoshi; Ohashi, Hirofumi; Sato, Hiroyuki; Yan, Xing; Murakami, Tomoyuki; Ohashi, Kazutaka; Nakagawa, Shigeaki; Goto, Minoru; Ueta, Shohei; Mozumi, Yasuhiro; Imai, Yoshiyuki; Tanaka, Nobuyuki; Okuda, Hiroyuki; Iwatsuki, Jin; Kubo, Shinji; Takada, Shoji; Nishihara, Tetsuo; Kunitomi, Kazuhiko

    2008-03-01

    The small-sized and safe cogeneration High Temperature Gas-cooled Reactor (HTGR) that can be used not only for electric power generation but also for hydrogen production and district heating is considered one of the most promising nuclear reactors for developing countries where sufficient infrastructure such as power grids is not provided. Thus, the small-sized cogeneration HTGR, named High Temperature Reactor 50-Cogeneration (HTR50C), was studied assuming that it should be constructed in developing countries. Specification, equipment configuration, etc. of the HTR50C were determined, and economical evaluation was made. As a result, it was shown that the HTR50C is economically competitive with small-sized light water reactors. (author)

  6. Twin cities institutional issues study cogenerated hot water district heating

    Energy Technology Data Exchange (ETDEWEB)

    Sundberg, R. E.; Leas, R.; Kolb, J. O.

    1979-01-01

    Community district heating, utilizing hot water produced through electrical/thermal cogeneration, is seen as an integral part of Minnesota's Energy Policy and Conservation Plan. Several studies have been conducted which consider the technical and institutional issues affecting implementation of cogenerated district heating in the Minneapolis and St. Paul Metropolitan Area. The state of the technical art of cogenerated hot water district heating is assumed to be transferable from European experience. Institutional questions relating to such factors as the form of ownership, financing, operation, regulation, and product marketability cannot be transferred from the European experience, and have been the subject of an extensive investigation. The form and function of the Institutional Issues Study, and some of the preliminary conclusions and recommendations resulting from the study are discussed.

  7. Texasgulf solar cogeneration program. Mid-term topical report

    Energy Technology Data Exchange (ETDEWEB)

    1981-02-01

    The status of technical activities of the Texasgulf Solar Cogeneration Program at the Comanche Creek Sulfur Mine is described. The program efforts reported focus on preparation of a system specification, selection of a site-specific configuration, conceptual design, and facility performance. Trade-off studies performed to select the site-specific cogeneration facility configuration that would be the basis for the conceptual design efforts are described. Study areas included solar system size, thermal energy storage, and field piping. The conceptual design status is described for the various subsystems of the Comanche Creek cogeneration facility. The subsystems include the collector, receiver, master control, fossil energy, energy storage, superheat boiler, electric power generation, and process heat subsystems. Computer models for insolation and performance are also briefly discussed. Appended is the system specification. (LEW)

  8. Residential cogeneration systems: review of the current technology

    International Nuclear Information System (INIS)

    Onovwiona, H.I.; Ugursal, V.I.

    2006-01-01

    There is a growing potential for the use of micro-cogeneration systems in the residential sector because they have the ability to produce both useful thermal energy and electricity from a single source of fuel such as oil or natural gas. In cogeneration systems, the efficiency of energy conversion increases to over 80% as compared to an average of 30-35% for conventional fossil fuel fired electricity generation systems. This increase in energy efficiency can result in lower costs and reduction in greenhouse gas emissions when compared to the conventional methods of generating heat and electricity separately. Cogeneration systems and equipment suitable for residential and small-scale commercial applications like hospitals, hotels or institutional buildings are available, and many new systems are under development. These products are used or aimed for meeting the electrical and thermal demands of a building for space and domestic hot water heating, and potentially, absorption cooling. The aim of this paper is to provide an up-to-date review of the various cogeneration technologies suitable for residential applications. The paper considers the various technologies available and under development for residential, i.e. single-family ( e ) and multi-family (10-30kW t ) applications, with focus on single-family applications. Technologies suitable for residential cogeneration systems include reciprocating internal combustion engine, micro-turbine, fuel cell, and reciprocating external combustion Stirling engine based cogeneration systems. The paper discusses the state of development and the performance, environmental benefits, and costs of these technologies. (author)

  9. Coadunation of technologies: Cogeneration and thermal energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaram, S.; Drost, M. K.; Brown, D. R.; Antoniak, Z. A.

    1993-09-01

    Cogeneration is playing an increasingly important role in providing an independent and on-site high-efficiency source of power generation and thermal energy for space heating and cooling, as well as industrial process heat applications. However, the range of applications of cogeneration technology could be further extended if the generation of electricity could be decoupled from the generation of thermal energy for process use or space conditioning. The technology of thermal energy storage (TES) provides just such a decoupling that allows for the production of dispatchable power while fully utilizing the thermal energy available from the prime mover of the cogeneration system. The thermal energy from the prime mover exhaust can be stored either as sensible heat or as latent heat and used during peak demand periods to produce electric power or process steam/hot water. However, the additional materials and equipment necessary for a TES system will add to the capital as well as maintenance costs. Therefore, the economic benefits of adding TES to a conventional cogeneration system would have to outweigh the increased costs of the combined system. This paper addresses some of the TES systems that are readily applicable to be combined with cogeneration systems, as well as provide an update on the current status of these TES systems. TES allows a cogeneration facility to (1) provide dispatchable electric power while providing a constant thermal load, and (2) increase peak capacity by providing economical cooling of the combustion turbine inlet air. The particular systems addressed are high-temperature diurnal TES, and TES for cooling the combustion turbine inlet air.

  10. Fuel strategies for natural gas fired cogeneration and IPP projects

    International Nuclear Information System (INIS)

    Gottlieb, J.W.

    1992-01-01

    This paper as published is the outline of a presentation on managing the risk of varying fuel costs as part of a successful fuel strategy for natural gas fired cogeneration and Independent Power Producer (IPP) projects. So long as the fuel cost that electric utilities recover from their ratepayers differs from the fuel costs incurred by IPP and Qualifying Facility (QF) plant operators, the largest variable cost risk of any QF or IPP will continue to be the cost of fuel. Managing that risk is the mission of any successful fuel procurement strategy. Unfortunately, a quick review of the last 20 years in the oil and gas industry reveals dramatic and substantial changes in price and fuel availability that few, if any, industry experts could have predicted in 1971. Recognizing that the fuel cost risk to a QF or IPP investor also spans a 20 year period, the typical term of a QF or IPP power purchase contract, a successful fuel procurement strategy must consider and address the likelihood of future changes. Due to federal and state regulatory changes made from 1978 to 1989, the current structure of the oil and gas industry appears to provide end-users with the tools to improve the manageability of fuel cost risks. QF and IPP developers can choose the type of service they desire and can negotiate most of the contractual elements of that service. Until electric utilities are allowed to flow through their rates the fuel costs incurred by QFs and IPPs, a thorough analysis of the available fuel procurement options prior to development of a QF or IPP will continue to be absolutely necessary

  11. Cogeneration handbook for the food processing industry. [Contains glossary

    Energy Technology Data Exchange (ETDEWEB)

    Eakin, D.E.; Fassbender, L.L.; Garrett-Price, B.A.; Moore, N.L.; Fasbender, A.G.; Gorges, H.A.

    1984-03-01

    The decision of whether to cogenerate involves several considerations, including technical, economic, environmental, legal, and regulatory issues. Each of these issues is addressed separately in this handbook. In addition, a chapter is included on preparing a three-phase work statement, which is needed to guide the design of a cogeneration system. In addition, an annotated bibliography and a glossary of terminology are provided. Appendix A provides an energy-use profile of the food processing industry. Appendices B through O provide specific information that will be called out in subsequent chapters.

  12. Cogeneration handbook for the petroleum refining industry. [Contains glossary

    Energy Technology Data Exchange (ETDEWEB)

    Fassbender, L.L.; Garrett-Price, B.A.; Moore, N.L.; Fassbender, A.G.; Eakin, D.E.; Gorges, H.A.

    1984-03-01

    The decision of whether to cogenerate involves several considerations, including technical, economic, environmental, legal, and regulatory issues. Each of these issues is addressed separately in this handbook. In addition, a chapter is included on preparing a three-phase work statement, which is needed to guide the design of a cogeneration system. In addition, an annotated bibliography and a glossary of terminology are provided. Appendix A provides an energy-use profile of the petroleum refining industry. Appendices B through O provide specific information that will be called out in subsequent chapters.

  13. Cogeneration using small sized series connected units: Feasibility study

    International Nuclear Information System (INIS)

    Tondelli, F.; Bergamini, G.

    1992-01-01

    This paper evidences the technical/economic feasibility of the use of methane fuelled modular cogeneration systems based on small series connected Otto or Diesel cycle engines delivering from 20 to 90 kW of power. Ample reference is made to the successful application of modular cogeneration systems to supply low temperature thermal energy to hospitals, hotels, food processing firms, etc., in Italy. The cost benefit analysis covers many aspects: design, manufacturing, operation, performance, maintenance and safety. Suggestions are also made as to optimum contractual arrangements for equipment service and maintenance, as well as, for the exchange of power with local utilities

  14. Cogeneration handbook for the pulp and paper industry. [Contains glossary

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, E.A.; Moore, N.L.; Fassbender, L.L.; Garrett-Price, B.A.; Fassbender, A.G.; Eakin, D.E.; Gorges, H.A.

    1984-03-01

    The decision of whether to cogenerate involves several considerations, including technical, economic, environmental, legal, and regulatory issues. Each of these issues is addressed separately in this handbook. In addition, a chapter is included on preparing a three-phase work statement, which is needed to guide the design of a cogeneration system. In addition, an annotated bibliography and a glossary of terminology are provided. Appendix A provides an energy-use profile of the pulp and paper industry. Appendices B and O provide specific information that will be called out in subsequent chapters.

  15. A new dynamism for the cogeneration of 2000 - from the medium to the mini-cogeneration; Une nouvelle dynamique pour la cogeneration en l'an 2000 - de la moyenne vers le mini-cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    In the framework of the Eco-Industries 2000 meeting, the ATEE organized a colloquium on the medium and mini-cogeneration market. This book presents the fourteen papers proposed at this colloquium bringing information on the cogeneration technology for the medium and mini-systems. The state of the art concerning the turbines and examples of dual systems (heating and warm water) are provided. Some economical aspects are also presented with the international and national market, the contracts management with EDF and the investments. (A.L.B.)

  16. Cogeneration in large processing power stations; Cogeneracion en grandes centrales de proceso

    Energy Technology Data Exchange (ETDEWEB)

    Munoz, Jose Manuel [Observatorio Ciudadano de la Energia A. C., (Mexico)

    2004-06-15

    In this communication it is spoken of the cogeneration in large processing power stations with or without electricity surplus, the characteristics of combined cycle power plants and a comparative analysis in a graph entitled Sale price of electricity in combined cycle and cogeneration power plants. The industrial plants, such as refineries, petrochemical, breweries, paper mills and cellulose plants, among others, with steam necessities for their processes, have the technical and economical conditions to cogenerate, that is, to produce steam and electricity simultaneously. In fact, many of such facilities that exist at the moment in any country, count on cogeneration equipment that allows them to obtain their electricity at a very low cost, taking advantage of the existence steam generators that anyway are indispensable to satisfy their demand. In Mexico, given the existing legal frame, the public services of electricity as well as the oil industry are activities of obligatory character for the State. For these reasons, the subject should be part of the agenda of planning of this power sector. The opportunities to which we are referring to, are valid for the small industries, but from the point of view of the national interest, they are more important for the large size facilities and in that rank, the most numerous are indeed in PEMEX, whereas large energy surplus and capacity would result into cogenerations in refineries and petrochemical facilities and they would be of a high value, precisely for the electricity public service, that is, for the Comision Federal de Electricidad (CFE). [Spanish] En esta ponencia se habla de la cogeneracion en grandes centrales de proceso con o sin excedentes de electricidad, las caracteristicas de plantas de ciclo combinado y se muestra el analisis comparativo en una grafica titulada precio de venta de electricidad en plantas de ciclo combinado y de cogeneracion. Las plantas industriales, tales como refinerias, petroquimicas

  17. The natural gas for electric energy production and other industrial inputs by using cogeneration; O gas natural na producao de energia eletrica e outros insumos industriais atraves da cogeracao

    Energy Technology Data Exchange (ETDEWEB)

    Mariotoni, Carlos Alberto [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil]. E-mail: cam@fec.unicamp.br

    2002-07-01

    This paper discusses the benefits of using natural gas in the cogeneration plants for electric power generation, and others inputs used in the different industrial sectors. Afterwards the end of the state monopoly on electrical energy generation, the cogeneration systems have been stimulated. The construction of the Brazil-Bolivia gas pipeline gives the real possibility of utilization of natural gas as an effective energy alternative what can help to minimize the industrial energy blackout, mainly in the pipeline neighbourhood. This work also presents both the economic and technical advantages of using natural gas at existing industrial plants in the region of Jundiai city at the State of Sao Paulo. (author)

  18. Gaz de France and cogeneration: a story which goes on; Gaz de France et la cogeneration: une histoire qui se poursuit

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-15

    This document presents the principle of natural gas cogeneration (gas turbine and gas engine) and gives a general overview of the cogeneration market in France since 1991 and up to 2001 (development factors, results). The perspectives and opportunities of cogeneration are analyzed with respect to the development of new technologies like fuel cells (principle, advantages and future) and to the future energy markets. Follows a compilation and an analysis of French regulation texts about cogeneration systems, their connection to the power grid, and the tariffs of electricity re-purchase by Electricite de France (EdF). (J.S.)

  19. Innovative coupling of cogeneration units with fire tube boilers: thermo-fluid dynamics of the fire tubes

    Science.gov (United States)

    Cioccolanti, L.; Arteconi, A.; Bartolini, C. M.; Polonara, F.

    2017-11-01

    Nowadays the thermal energy demand in the industrial sector is usually satisfied by means of fire tube boilers while electricity is supplied from the grid. Alternatively cogeneration units could be adopted for thermal and electrical energy self-production, whilst installing boilers only as back-up units. However, even when cogeneration is profitable, it is not widespread because industries are usually unwilling to accept cogeneration plants for reliability and high investment costs issues. In this work a system aimed at overcoming the above mentioned market difficulties is proposed. It consists of an innovative coupling of a combined heat and power unit with a modified fire tube boiler. In particular, a CFD analysis was carried out by the authors in order to address the most critical aspects related with the coupling of the two systems. More precisely, the following aspects were evaluated in detail: (i) pressure losses of the exhausts going from the prime mover to the boiler due to the sudden cross-section area variations; (ii) thermal power recoverable from the exhausts in the tubes of the boiler; (iii) dependence of the system on the final users’ specification.

  20. Comparative Study of Electric Energy Storages and Thermal Energy Auxiliaries for Improving Wind Power Integration in the Cogeneration System

    Directory of Open Access Journals (Sweden)

    Yanjuan Yu

    2018-01-01

    Full Text Available In regards to the cogeneration system in Northern China, mainly supported by combined heat and power (CHP plants, it usually offers limited operation flexibility due to the joint production of electric and thermal power. For that large-scale wind farms included in the cogeneration system, a large amount of wind energy may have to be wasted. To solve this issue, the utilization of the electric energy storages and the thermal energy auxiliaries are recommended, including pumped hydro storage (PHS, compressed air energy storage (CAES, hydrogen-based energy storage (HES, heat storage (HS, electric boilers (EB, and heat pumps (HP. This paper proposes a general evaluation method to compare the performance of these six different approaches for promoting wind power integration. In consideration of saving coal consumption, reducing CO2 emissions, and increasing investment cost, the comprehensive benefit is defined as the evaluation index. Specifically, a wind-thermal conflicting expression (WTCE is put forward to simplify the formulation of the comprehensive benefit. Further, according to the cogeneration system of the West Inner Mongolia (WIM power grid, a test system is modelled to perform the comparison of the six different approaches. The results show that introducing the electric energy storages and the thermal energy auxiliaries can both contribute to facilitating wind power integration, and the HP can provide the best comprehensive benefit.

  1. National district-heating program: generic city district-heating and cooling system from cogeneration retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Davis, H.; Grammel, S.; Kuzanek, J.; Levine, E.

    1981-02-01

    A study, designed to aid in evaluating the feasibility of a district heating and cooling system that uses heat supplied by existing electric generating plants retrofitted for cogeneration, is presented. Based on thermal demands of a metropolitan area, the District Heating and Cooling System (DHCS) model estimates the cost of the retrofit. Environmental impact and the potential for scarce-fuel savings also are assessed by this model. The computer program used is the District Heating Strategy Model (DHSM). Section 2 identifies metropolitan demand sectors and describes the data acquisition method. Section 3 defines thermal energy supply sources and shows how each is located. Program output is summarized in terms of financial data, electrical and thermal loads, and a ranking of existing power plants. Section 4 assesses air pollutant emissions and DHCS fuel-use requirements. Finally, Sec. 5 considers the economics of the DHCS and its costs vs benefits.

  2. 78 FR 43198 - Watson Cogeneration Company; Notice of Filing

    Science.gov (United States)

    2013-07-19

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. TX13-1-000] Watson... Commission's (Commission) Regulations, 18 CFR 36.1, Watson Cogeneration Company filed an application... physical interconnection to the Watson facility; (2) direct SCE and California Independent System Operator...

  3. Diffusion paths for micro cogeneration using hydrogen in the Netherlands

    NARCIS (Netherlands)

    Taanman, M.; Groot, A.de; Kemp, R.; Verspagen, B.

    2008-01-01

    We estimate the diffusion of micro cogeneration systems (MiCoGen) using hydrogen produced from natural gas in the Netherlands for the 2000-2050 period on the basis of economical factors. The diffusion is important for the transition to a hydrogen economy based on renewables, with natural gas paving

  4. Financial gap calculations for existing cogeneration 2008

    International Nuclear Information System (INIS)

    Hers, S.J.; Wetzels, W.; Seebregts, A.J.; Van der Welle, A.J.

    2008-05-01

    The Dutch SDE (abbreviation for the renewable energy incentive) subsidy scheme promotes the reduction of CO2 emissions which results from the use of Combined Heat and Power (CHP) plants. This report calculates the profitability of operation of existing CHP plants. This information can be used for decision making on the SDE subsidy for existing CHP plants in 2008 [nl

  5. New purchasing conditions for the electricity produced by cogeneration; Nouvelles conditions d`achat de l`electricite produite par cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    Pierret, Ch.

    1998-12-31

    This short note summarizes the new conditions of electricity purchase as stipulated in the contracts passed between Electricite de France (EdF) and the independent companies exploiting cogeneration units. These new conditions should allow the continuation of the development of cogeneration units in a power market progressively opened to competition. (J.S.)

  6. Integration of heat treatment of wood with cogeneration production and district heating; Vaermebehandling av trae integrerad med kraftvaermeproduktion och fjaerrvaerme

    Energy Technology Data Exchange (ETDEWEB)

    Delin, Lennart; Essen, Henrik (AaF, Stockholm (Sweden))

    2011-05-15

    Heat treatment of wood changes the properties of wood so that the moisture uptake is reduced and the wood movements are reduced at variations in the ambient air humidity. The wood gets an increased resistance to rot and can therefore replace impregnated wood in certain applications. Heat treated wood is however not suitable for direct contact with soil. The strength is also reduced by heat treatment, so it is not recommended for supporting constructions. No additives whatsoever are used in the treatment, so the heat treated wood is very advantageous from an environmental point of view. The wood is dried completely at the heat treatment and heated to about 200 deg C. The question has hence been put, if it is advantageous to collocate a heat treatment plant with district heating or a power cogeneration plant. The aim of the study is to assess the value of such a collocation. Existing heat treatment plants are both few and small and the calculations have hence been made for how a large plant could be designed. A market study is included to assess the market for this type of plants. This shows that the present market for heat treated wood is very small. A full scale treatment plant of the type discussed in this study could probably not be built, since even single plants of this size would require a too large part of the market. The potential to replace impregnated wood is on the other hand very large. The cost for large scale heat treatment should be significantly lower than for impregnated wood and the cost for handling hazardous waste (which impregnated wood is classified as) is also removed. There should therefore be a potential for a future much larger volume of heat treated wood. The study shows that the energetic profit of collocation of a heat treatment plant for wood with district heating or power cogeneration plants is of lower importance. Maximally about 0.5 MSEK/year can be saved for a 25 000 m3/year plant. The initial drying of all sawn lumber has much more

  7. Cogeneration in greenhouses dropping down?; Warmtekracht in de glastuinbouw verder onderuit?

    Energy Technology Data Exchange (ETDEWEB)

    Schlatmann, S. [Cogen Projects, Utrecht (Netherlands)

    2003-02-01

    Several energy companies are currently reorganising their gas engine parks. This is drastically reducing the installed gas engine generating capacity in greenhouse market gardening. The remaining plants are operating fewer hours. The new incentive program for co-generation of heat and power that the Ministry for Economic Affairs wants to launch is not exactly improving matters. How did it get to this point. [Dutch] Verschillende energiebedrijven saneren op dit moment hun gasmotorenpark. Hierdoor neemt het opgesteld vermogen aan gasmotoren in de glastuinbouwsector flink af. Installaties die blijven staan maken minder draaiuren. De nieuwe stimuleringsregeling voor warmtekracht die het ministerie van Economische Zaken wil invoeren, maakt de situatie er niet beter op. Hoe heeft het zover kunnen komen.

  8. Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: Fallacies and counterexamples

    International Nuclear Information System (INIS)

    Shaaban, M.; Azit, A.H.; Nor, K.M.

    2011-01-01

    Despite the abundance of natural gas reserves in Malaysia coupled with serious government thrusts to promote cogeneration, its (cogeneration) development pace lags far off expectations. There are widespread fallacies among potential cogeneration developers and concerned professionals that cogeneration is uncompetitive in Malaysia due to existing policies of subsidized gas prices and grid-connection charges. This paper exposes these fallacies through counterexamples of practical cogeneration system design and evaluation of some segments of the industrial and service sectors in Peninsular Malaysia. The electrical and thermal characteristics of the cogeneration were modeled based on heat rate characteristics at partial loading patterns. A hierarchical mathematical programming approach that uses mixed-integer nonlinear optimization and dynamic programming principle, if necessary, is employed to determine the optimal size of cogeneration and its related auxiliary equipment as well as the optimal operation schedule. Financial assessment is integrated at a later stage to assess the economic viability of the system. Analyses of the cogeneration potential for several facilities of miscellaneous activities were carried out using various gas and electricity prices. Results obtained consistently rebuff the perpetuated fallacies and confirm that there is no real barrier to cogeneration development in Malaysia under current policies of gas prices and electricity tariffs. - Highlights: → Mixed-integer nonlinear programming and dynamic programming are used in the design. → Various loading levels are modeled and hourly operation schedule is determined. → Standby electricity charge has a minimal impact on cogeneration feasibility. → Gas and electricity prices are interrelated and affect cogeneration investment. → Under existing policies, there is no barrier to cogeneration adoption in Malaysia.

  9. Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: Fallacies and counterexamples

    Energy Technology Data Exchange (ETDEWEB)

    Shaaban, M., E-mail: m.shaaban@fke.utm.my [Centre of Electrical Energy Systems, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Johor Bahru (Malaysia); Azit, A.H. [Tenaga Nasional Berhad, Wisma TNB, Jalan Timur, 46200 Petaling Jaya, Selangor (Malaysia); Nor, K.M. [Centre of Electrical Energy Systems, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Johor Bahru (Malaysia)

    2011-09-15

    Despite the abundance of natural gas reserves in Malaysia coupled with serious government thrusts to promote cogeneration, its (cogeneration) development pace lags far off expectations. There are widespread fallacies among potential cogeneration developers and concerned professionals that cogeneration is uncompetitive in Malaysia due to existing policies of subsidized gas prices and grid-connection charges. This paper exposes these fallacies through counterexamples of practical cogeneration system design and evaluation of some segments of the industrial and service sectors in Peninsular Malaysia. The electrical and thermal characteristics of the cogeneration were modeled based on heat rate characteristics at partial loading patterns. A hierarchical mathematical programming approach that uses mixed-integer nonlinear optimization and dynamic programming principle, if necessary, is employed to determine the optimal size of cogeneration and its related auxiliary equipment as well as the optimal operation schedule. Financial assessment is integrated at a later stage to assess the economic viability of the system. Analyses of the cogeneration potential for several facilities of miscellaneous activities were carried out using various gas and electricity prices. Results obtained consistently rebuff the perpetuated fallacies and confirm that there is no real barrier to cogeneration development in Malaysia under current policies of gas prices and electricity tariffs. - Highlights: > Mixed-integer nonlinear programming and dynamic programming are used in the design. > Various loading levels are modeled and hourly operation schedule is determined. > Standby electricity charge has a minimal impact on cogeneration feasibility. > Gas and electricity prices are interrelated and affect cogeneration investment. > Under existing policies, there is no barrier to cogeneration adoption in Malaysia.

  10. Reviews on Fuel Cell Technology for Valuable Chemicals and Energy Co-Generation

    OpenAIRE

    Wisitsree Wiyaratn

    2010-01-01

    This paper provides a review of co-generation process in fuel cell type reactor to produce valuable chemical compounds along with electricity. The chemicals and energy co-generation processes have been shown to be a promising alternative to conventional reactors and conventional fuel cells with pure water as a byproduct. This paper reviews researches on chemicals and energy co-generation technologies of three types of promising fuel cell i.e. solid oxide fuel cell (SOFC), alkaline fuel cell (...

  11. EVALUATION OF ENERGY COGENERATION FROM SUGAR CANE BAGASSE

    Directory of Open Access Journals (Sweden)

    Hanserth Abreu Elizundia

    2016-01-01

    Full Text Available In this paper were simulated and evaluated five alternatives of cogeneration scheme that promote a higher production of thermal and electrical energies as well as its right management. The first three alternatives are directed to increasing the boiler pressure and a change of steam turbines which are the extraction-condensation type, and then the fourth alternative proposed a boiler change to implement a bubbling fluidized bed and finally in the fifth alternative a scheme of biomass gasification is analyzed. All scheme were analyzed energetic and exergetically. The five cogeneration alternatives were simulated in ASPEN PLUS; they showed that the largest surplus bagasse and electricity are obtained with the scheme of a biomass gasification and the worst results in these parameters were obtained in the alternative that function in low pressure and temperature parameters

  12. District heating and co-generation in Slovenia

    International Nuclear Information System (INIS)

    Hrovatin, Franc; Pecaric, Marko; Perovic, Olgica

    2000-01-01

    Recent development of district heating systems, gasification and co-generation processes in local communities in Slovenia as well as current status, potentials, possibilities and plans for further development in this sphere are presented. The current status presents energy production, distribution and use in district heating systems and in local gas distribution networks. An analysis of the energy and power generated and distributed in district power systems, made with regard to the size of the system, fuel used, type of consumers and the way of production, is given. Growth in different areas of local power systems in the period of last years is included. Potentials in the sphere of electrical energy and heat co-generation were assessed. Some possibilities and experience in heat energy storage are given and trends and plans for further development are introduced. (Authors)

  13. Cogeneration for the Rouen hospital; La cogenerationau CHU de Rouen

    Energy Technology Data Exchange (ETDEWEB)

    Bartolucci, P. [CHU, Hopital Charles Nicolle de Rouen, 76 (France)

    1996-07-01

    In order to decrease the annual costs of heat and electric power at the Rouen hospital (France), a cogeneration system has been studied, using gas turbines or gas engines (fuel oil is excluded for environmental reasons). Electric power needs being larger than thermal needs, gas motors were preferred. The technical specifications of the equipment are described and annual power consumptions and generations (sellback to the national grid) are evaluated. An economic analysis is presented together with the technical drawings of the system

  14. Cost of electricity from small scale co-generation of electricity and heat

    Energy Technology Data Exchange (ETDEWEB)

    Kjellstroem, Bjoern

    2012-07-15

    There is an increasing interest in Sweden for using also small heat loads for cogeneration of electricity and heat. Increased use of small CHP-plants with heat supply capacities from a few 100 kW(h) up to 10 MW(h) cannot change the structure of the electricity supply system significantly, but could give an important contribution of 2 - 6 TWh(e) annually. The objective of this study was to clarify under what conditions electricity can be generated in small wood fired CHP-plants in Sweden at costs that can compete with those for plants using fossil fuels or nuclear energy. The capacity range studied was 2 - 10 MW(h). The results should facilitate decisions about the meaningfulness of considering CHP as an option when new heat supply systems for small communities or sawmills are planned. At the price for green certificates in Sweden, 250 - 300 SEK/MWh(e), generation costs in small wood fired CHP-plants should be below about 775 SEK/MWh(e) to compete with new nuclear power plants and below about 925 SEK/MWh(e) to compete with generation using fossil fuels.

  15. Biomass cogeneration: industry response for energy security and environmental consideration

    International Nuclear Information System (INIS)

    Bacareza-Pacudan, L.; Lacrosse, L.; Pennington, M.; Dale Gonzales, A.

    1999-01-01

    Biomass occurs in abundance in the highly agricultural-based countries of South-East Asia. If these are processed in the wood and agro-processing industries, large volumes of residues are generated. The residue are potential sources of energy which the industries can tap through the use of cogeneration systems, in order to meet their own thermal and electrical requirements. This will reduce the industry's dependence on power from the grid and thus increase their own self-sufficiency in terms of energy. Biomass cogeneration brings the environmental, as well as economic benefits to the industries. It makes use of clean and energy-efficient technologies and utilises biomass as fuels which cause less environment al pollution and the greenhouse effect, as against the use of fossil fuels. A particular mill that embarks on biomass cogeneration is also able to realise, among others, income from the export of excess electricity to the grid. Biomass residue if not used for other purposes have negative values as they need to be disposed of. They can, however, be profit-generating as well. (Author)

  16. Investigations on an oriented cooling design for thermoelectric cogenerations

    International Nuclear Information System (INIS)

    Zheng, X F; Yan, Y Y; Liu, C X

    2012-01-01

    In thermoelectric application, it is widely known that the material limitation has still been the chief barrier of lifting its application to a higher level. Continuous efforts are extensively being made in developing novel material structures and constructions for thermoelectric modules with higher conversion efficiency. However, the overall system efficiency, which is one of the major parameters that most of the engineer and users care about, is not only ruled by the properties of applied thermoelectric materials, but also decided by the design of heat exchangers used on both sides of thermoelectric modules. Focusing on the cooling capacity and hydraulic characteristics of heat exchanger, this paper introduces an oriented cooling method for the domestic thermoelectric cogeneration, which delivers system efficiency up to 80%. This purpose-oriented cooling plate is designed for thermoelectric cogeneration for the residential houses installed with boiler or other heating facilities with a considerable amount of unused heat. The design enables Thermoelectric Cogeneration System (TCS) to be flexibly integrated into the existing hydraulic system. The mathematical model for the cooling plate has been established for a well understanding at the theoretical level. The performance of cooling plate has been investigated in a series of experimental studies which have been conducted under different coolant inlet velocity and temperature. The economic operating zone in which a good system performance could be achieved has been discussed and identified for the current configuration.

  17. Benefices environnementaux de la cogeneration d'energie en milieu hospitalier et cas de l'Hopital de Moncton

    Science.gov (United States)

    Kone, Diakalia

    The present study aimed at assessing the environmental benefits of power management practices based on cogeneration in the particular industrial sector of hospitals and healthcare. Cogeneration power systems, also known as "Combined Heat and Power" (CHP) or Cogen, supply on-site electricity and heat from a single fuel source (natural gas in general). While the efficiency of conventional plants to produce power and heat separately is limited to about 30%, the efficiency of a CHP plant is close to 80% and can reach up to 90% in some applications (Borbely et Kreider, 2001). One of the distinctive features of hospitals is their continuous demand for both type of energy (electricity and heat), which makes them good candidate for cogeneration. However, in North America at the present time, less than 5% of hospitals run on CHP. Most are being supplied with electricity by conventional power plants, run by specialized companies, and use on-site boiler(s) to generate heat. Energy spending can reach up to 3% of an hospital's annual operational budget. There are also environmental impacts related to current energy supply and use in hospitals. For instance, the burning of fossil fuels releases greenhouse gases (GHG), which contribute to human health problems and climate change. The first objective of the study was to outline the main benefits and challenges faced by hospitals that aim at becoming their own energy co-generator, in comparison to having power and heat produced separately. Our second objective was to assess prospectively (proactively) the environmental impacts of a cogeneration plant that is being planned, but not yet operated, in a Canadian hospital. The methodology was based on literature reviews and on a case study, namely that of The Moncton Hospital (TMH)/L'Hopital de Moncton, Moncton, New Brunswick, Canada. This hospital is considered a large hospital with 375 beds and a major and expanding ambulatory care service. It is also in the process of developing a 1

  18. Impact of support schemes and barriers in Europe on the evolution of cogeneration

    International Nuclear Information System (INIS)

    Moya, José Antonio

    2013-01-01

    This paper analyses the effectiveness of different support measures to promote cogeneration in the European Union. The analysis looks into the average progress of cogeneration between two different periods. The economic effect of the support measures in each country is quantified with the help of a cost–benefit analysis carried out by the Cogeneration Observatory and Dissemination Europe (CODE) project. The scope of this study is necessarily affected by the need to limit the number of projects and support measures. However, there is no evidence of a relationship between the economic advantage offered by support measures and the deployment of cogeneration in the Member States. The study considers the effect of different barriers (reported by the Member States) on the promotion of cogeneration. The individual analyses of the barriers differ widely in quality and depth. When some barriers are reported, there is an increase of the variability of the penetration of cogeneration. This counter-intuitive fact leads us to conclude that there is a lack of consistency in the barriers reported, and a clear need for consistent reporting on barriers. The possible effect of competition between measures supporting combined heat and power and renewable energy sources is also analysed. - Highlights: • Support measures to promote cogeneration are analysed. • The growth of cogeneration in European countries is not aligned with the measures in place. • None of the reported barriers for cogeneration can be considered a clear show-stopper. • The variation in the development of cogeneration when some barriers are reported raises questions about the reporting. • Countries with a high share of cogeneration are sensitive to the continuity or discontinuity of support

  19. The performance investigation of a temperature cascaded cogeneration system equipped with adsorption desalination unit

    KAUST Repository

    Myat, Aung

    2013-02-01

    This paper presents the performance investigation of a temperature cascaded cogeneration plant, shortly in TCCP, equipped with an efficient waste heat recovery system. The TCCP or cogeneration system produces four types of useful energy namely (i) electricity, (ii) steam, (iii) cooling, and (iv) dehumidification and distilled water by utilizing single energy source. The TCCP comprises a Capstone C30 micro-turbine that generates nominal capacity of 26 kW of electricity, a compact and efficient waste heat recovery system and a host of waste heatactivated devices namely (i) a steam generator, (ii) an absorption chiller, (iii) an adsorption desalination system, and (iv) a multi-bed desiccant dehumidifier. The analysis is performed under different operation conditions such as heat source temperatures, flow rates of heat transfer fluids and chilled water inlet temperatures. The only single heat source for TCCP is obtained from exhaust gas of micro-turbine and it is channeled to a series of waste heat recovery heat exchangers to steam and hot water at different temperatures. Hot water produced by such a compact heat exchangers is the driving heat source to produce steam of 15 kg/h, cooling of 2 Rton, dehumidification of 2 Rton, and distilled water of 0.7 m3/day. A set of experiments, both part load and full load, of micro-turbine is conducted to examine the electricity generation and the exhaust gas temperature. It is observed that energy utilization factor could achieve as high as 70% while fuel energy saving ratio is found to be 28%. © 2013 Desalination Publications. All rights reserved.

  20. Technical-Economic Evaluation of a Cogeneration Unit Considering Carbon Emission Savings

    Directory of Open Access Journals (Sweden)

    Ana Christina Ferreira

    2014-06-01

    Full Text Available The support of combined heat and power production systems has gained policy attention, because these are often considered to be less polluting and more efficient than conventional energy conversion systems. As a consequence, the potential market for these energy systems that contribute to reduce greenhouse gas emissions and to enhance energy security on a national level, is shifting from large-scale existing units to small and micro-size emerging technologies. This paper presents a numerical model based on a cost-benefit analysis used to design an optimal cogeneration system for a small-scale building application, considering the Portuguese context and the comparison with the harmonized efficiency reference values for the separate production of electricity and useful heat. The model includes the identification of the objective function terms (i.e., the elements involved in the financial analysis across the system lifetime and the economic evaluation of costs and benefits of the combined heat and power production system. The economic viability of cogeneration systems significantly depends on system technology, client energy requirements and support schemes implemented in the respective countries. A strategic approach is necessary to adequately embed the new technology as a feasible solution in terms of investment and operational costs. Only by matching the energy supply to the needs and expectations of the energy users, it will be possible to improve the market competitiveness of these alternative power production plants. The optimal solution disclosed a positive annual worth, which is higher if the carbon emission savings are monetized. In addition, the optimal system represents a more efficient way to produce useful heat and electricity (i.e. a positive primary energy saving and to reduce gas emissions. A cost-benefit analysis can be applied for the techno-economic evaluation of a CHP system by assessing the monetary socio-environmental costs

  1. Thermodynamic and economic optimization of a solar-powered Stirling engine for micro-cogeneration purposes

    International Nuclear Information System (INIS)

    Ferreira, Ana C.; Nunes, Manuel L.; Teixeira, José C.F.; Martins, Luís A.S.B.; Teixeira, Senhorinha F.C.F.

    2016-01-01

    Micro-cogeneration systems are a promising technology for improving the energy efficiency near the end user, allowing the optimal use of the primary energy sources and significant reductions in carbon emissions. Its use, still incipient, has a great potential for applications in the residential sector. This study aims to develop a methodology for the thermal-economic optimization of micro cogeneration units using Stirling engine as prime mover and concentrated solar energy as the heat source. The thermal-economic optimization was formulated considering the maximization of the annual worth from the system operation, subjected to the nonlinear thermodynamic and economic constraints. The physical model includes the limitations in the heat transfer processes and losses due to the pumping effects and the costing methodology was defined considering a purchase cost equation representative of each system component. Geometric and operational parameters were selected as decision variables. Numerical simulations were developed in MatLab ® programming language and the Generalized Pattern Search optimization algorithm with MADSPositiveBasis2N was used in the determination of the optimal solution. A positive annual worth for the defined input simulation conditions and the economic analysis disclosed a system, economically attractive, with a payback period of approximately 10 years. - Highlights: • Application of optimization methods to model a renewable powered Stirling engine. • The aim is to optimize design of each plant-component for the best economical outcome. • The objective function is the maximization of annual worth of micro-CHP system. • The optimal solution is sensitive to electricity feed-in-tariffs and fuel prices fluctuations. • The optimal solution is economically attractive, with a payback period of ≈10 years.

  2. Dynamics of decentralization: The case of micro cogeneration diffusion in Germany

    International Nuclear Information System (INIS)

    Praetorius, Barbara; Schneider, Lambert

    2005-01-01

    Micro cogeneration is the simultaneous generation of heat and electricity in small units; it is expected to allow for a higher energy efficiency than separate generation. For Germany, the potential of micro cogeneration has been estimated with about 3 GW. Introduced in a larger scale and as part of a general move towards distributed generation, micro cogeneration may contribute to substantial structural changes on electricity and heat markets. We start with an assessment of existing micro cogeneration technologies, including reciprocating engines, Stirling engines and fuel cells, and describe their characteristics and state of development. Based on a model to calculate costs of micro cogeneration operation, we examine their economic feasibility in Germany in a number of typical applications from an operator's and a societal perspective. On this basis, we explore the actual dynamics of its diffusion in Germany. We analyze the interests, attitudes and strategies of actors concerned with implementing micro cogeneration, such as network operators, appliance industry, gas and electricity suppliers, etc. We explore the impacts of their (diverging) interests and strategies and mirror them with the economic potential and institutional setting for micro cogeneration with respect to competition, grid access and transaction costs. We conclude with assessing barriers for and measures to facilitate the diffusion of micro cogeneration in Germany

  3. Combined cycles and cogeneration with natural gas and alternative fuels; Cicli combinati e cogenerazione con gas naturale e combustibili alternativi

    Energy Technology Data Exchange (ETDEWEB)

    Gusso, R. [Turbotecnica SpA, Florence (Italy)

    1992-12-31

    Since 1985 there has been a sharp increase world-wide in the sales of gas turbines. The main reasons for this are: the improved designs allowing better gas turbine and, thus, combined cycle efficiencies; the good fuel use indices in the the case of cogeneration; the versatility of the gas turbines even with poly-fuel plants; greatly limited exhaust emissions; and lower manufacturing costs and delivery times with respect to conventional plants. This paper after a brief discussion on the evolution in gas turbine applications in the world and in Italy, assesses their use and environmental impacts with fuels other than natural gas. The paper then reviews Italian efforts to develop power plants incorporating combined cycles and the gasification of coal, residual, and other low calorific value fuels.

  4. Modeling and Experimental Study of a Small Scale Olive Pomace Gasifier for Cogeneration: Energy and Profitability Analysis

    Directory of Open Access Journals (Sweden)

    Domenico Borello

    2017-11-01

    Full Text Available A thermodynamic model of a combined heat and power (CHP plant, fed by syngas produced by dry olive pomace gasification is here presented. An experimental study is carried out to inform the proposed model. The plant is designed to produce electric power (200 kWel and hot-water by using a cogenerative micro gas turbine (micro GT. Before being released, exhausts are used to dry the biomass from 50% to 17% wb. The ChemCad software is used to model the gasification process, and input data to inform the model are taken from experimental tests. The micro GT and cogeneration sections are modeled assuming data from existing commercial plants. The paper analyzes the whole conversion process from wet biomass to heat and power production, reporting energy balances and costs analysis. The investment profitability is assessed in light of the Italian regulations, which include feed-in-tariffs for biomass based electricity generation.

  5. Development of a thermal scheme for a cogeneration combined-cycle unit with an SVBR-100 reactor

    Science.gov (United States)

    Kasilov, V. F.; Dudolin, A. A.; Krasheninnikov, S. M.

    2017-02-01

    At present, the prospects for development of district heating that can increase the effectiveness of nuclear power stations (NPS), cut down their payback period, and improve protection of the environment against harmful emissions are being examined in the nuclear power industry of Russia. It is noted that the efficiency of nuclear cogeneration power stations (NCPS) is drastically affected by the expenses for heat networks and heat losses during transportation of a heat carrier through them, since NPSs are usually located far away from urban area boundaries as required for radiation safety of the population. The prospects for using cogeneration power units with small or medium power reactors at NPSs, including combined-cycle units and their performance indices, are described. The developed thermal scheme of a cogeneration combined-cycle unit (CCU) with an SBVR-100 nuclear reactor (NCCU) is presented. This NCCU should use a GE 6FA gasturbine unit (GTU) and a steam-turbine unit (STU) with a two-stage district heating plant. Saturated steam from the nuclear reactor is superheated in a heat-recovery steam generator (HRSG) to 560-580°C so that a separator-superheater can be excluded from the thermal cycle of the turbine unit. In addition, supplemental fuel firing in HRSG is examined. NCCU effectiveness indices are given as a function of the ambient air temperature. Results of calculations of the thermal cycle performance under condensing operating conditions indicate that the gross electric efficiency η el NCCU gr of = 48% and N el NCCU gr = 345 MW can be achieved. This efficiency is at maximum for NCCU with an SVBR-100 reactor. The conclusion is made that the cost of NCCU installed kW should be estimated, and the issue associated with NCCUs siting with reference to urban area boundaries must be solved.

  6. Thermal design and technical economical and environmental analyses of a hydrogen fired multi-objective cogeneration system

    International Nuclear Information System (INIS)

    Durmaz, A; Yilmazoglu, M. Z.; Pasoglu, A.

    2007-01-01

    Approximately 85% of rapidly increasing world energy demand is supplied by fossil fuels. Extreme usage of fossil fuels causes serious global warming and environmental problems in form of air, soil and water pollutions. The period, in which fossil fuel reserves are decreasing, energy costs are increasing rapidly and new energy sources and technologies do not exist on the horizon, can be called as the expensive and critical energy period. Hydrogen becomes a matter of primary importance as a candidate energy source and carrier in the critical energy period and beyond to solve the energy and environmental problems radically. In this respect, the main obstacle for the use of hydrogen is the high cost of hydrogen production, which is expected to be decreased in the feature. The aim of this study is to examine how hydrogen energy will be able to be integrated with the existing energy substructure with technical and economical dimensions. In this sense, a multi objective hydrogen fired gas turbine cogeneration system is designed and optimized. Technical and economical analyses depending on the load conditions and different hydrogen production cost are carried out. It is possible that the co-generated heat is to be marketed for residence and industrial plants in the surrounding at or under market prices. The produced electricity however can only be sold to the public grid at a high unit support price which is only obtainable in case of the development of new energy technologies. This price should however be kept within the nowadays supportable energy price range. The main mechanism to be used during the design stage of the system to achieve this goal is to decrease the amortization and operational costs which lead to decrease investment and fuel costs and to increase the system load factor and co-generated heat revenues

  7. Economic evaluation of externally fired gas turbine cycles for small-scale biomass cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    Anheden, Marie [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Chemical Engineering and Technology

    2001-01-01

    In this conceptual study, externally fired gas turbine (EFGT) cycles in combination with a biomass-fueled, atmospheric circulating fluidized bed (CFB) furnace are investigated for small scale heat and power production ({approx} 8 MW fuel input). Three cycle configurations are considered: closed cycle, with nitrogen, helium, and a helium/carbon dioxide mixture as working fluids; open cycle operating in parallel to the CFB system; and open cycle with a series connection to the CFB system. Intercooling, postcooling, and recuperation are employed with the goal of maximizing efficiency. Aside from a thermodynamic performance analysis, the study includes an economic analysis of both the closed and open externally fired gas turbine configurations, and comparisons are made with existing and emerging alternatives for small-scale biomass cogeneration. Simulation results show that thermodynamic performance varies slightly between the different configurations and working fluids, with electrical efficiencies of 31-38% (LHV) and total efficiency of 85-106% (LHV). The economic evaluation shows that the turbomachinery and the CFB furnace dominate the total plant cost, with each contributing about 1/3 of the total installed equipment cost. The specific capital cost for installation in Sweden in 1998 currency is calculated as 26-31 kSEK/kW{sub e} which is equivalent to 3 200-3 900 USD/kW{sub e} or 2 700-3 300 EUR/kW{sub e} .The cost of electricity, COE, is estimated to 590-670 SEK/MWh{sub e} (equivalent to 73-84 USD/MWh{sub e} or 62-71 EUR/MWh{sub e}) for 4 000 full load hours per year in a cogeneration application. Comparing the economic results for the externally fired gas turbine cycles in a slightly larger scale (40-50 MW{sub f}) to the economics of conventional biomass fired steam turbine cycles shows that the cost of electricity for the two plant configurations are roughly the same with a COE of 300-350 SEK/MWh{sub e}. It is believed that the economic performance of the EFGT

  8. Succeeding in the grafting of a cogeneration system to an old space heating installation; Reussir la greffe d'une cogeneration sur une installation ancienne

    Energy Technology Data Exchange (ETDEWEB)

    Desjardins, C.

    2003-05-01

    Substantial energy savings can be made in the tertiary sector thanks to the implementation of cogeneration systems. The 'grafting' of a cogeneration system to an existing space heating installation requires to take some precautions which are explained in this technical article using a real example. In particular, it shows why, despite some visible improvements, some installations can suffer from a lack of performance. (J.S.)

  9. Alternatives to electrical cogeneration: The direct application of steam engines

    International Nuclear Information System (INIS)

    Phillips, W.C.

    1993-01-01

    Although small to medium sized industrial facilities are aware of electrical cogeneration, often they are too small for it to be economically justifiable. The direct application of steam turbine power to equipment formerly powered by electric motors, can allow them to use steam capacity to reduce electrical demand and consumption, bypassing cogeneration. Cogeneration converts the heat energy of steam into circular mechanical motion and then converts the circular mechanical motion into electricity. Each conversion entails a loss of energy due to friction and other conversion losses. A substantial amount of the generated electricity is then converted back into circular motion with electric motors, again incurring energy losses. Directly applying the mechanical motion of turbines eliminates both the motion-to-electricity (generator) and the electricity-to-motion (motor) conversion losses. Excess steam capacity during the summer is not unusual for facilities that use steam to provide winter heating. Similarly, most of these facilities experience a large electrical demand peak during the cooling season due to the electricity needed to operate centrifugal chillers. Steam capacity via a turbine to power the chillers can allow the boilers to operate at a higher loading while reducing electrical consumption and demand precisely those periods when demand reduction is most needed. In facilities where the steam generating capacity is sufficient, air compressors provide an appropriate year-round application for turbine power. This paper is the result of an on-going project by the Energy Division, State of North Carolina, Department of Economic and Community Development, in conjunction with the University of North Carolina at Charlotte. The objective of this project is to educate the operating engineers and managers of small to medium sized manufacturing facilities on the technical application and economic justification of steam turbine power

  10. The cogeneration and small power production manual. 3rd edition

    International Nuclear Information System (INIS)

    Spiewak, S.A.

    1990-01-01

    This book is divided into six sections covering regulations, environmental issues, engineering, contract, financing, and taxes. The edition adds a comprehensive 80-page chapter outlining how to prepare for electric power shortages, including details on rate structure, tariff negotiation, contract-based rates, partial requirement service, supplementary, backup, and interruptible rates, and retail sale of electric power. The engineering section covers optimum cogeneration system design, operational considerations, and energy efficiency. Combustion turbines, diesel engines, gas engines, rotary engines, steam turbines, and electric generators are covered in detail

  11. FY1998 survey on preparation of data collection related to new energy technology development (cogeneration); 1998 nendo shin energy gijutsu kaihatsu kankei data shu sakusei chosa (cogeneration) chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    New energy technologies have had the subsidy institutions established in association with advancement of the technologies, and such introduction promoting measures developed as the introduction assistance and advisory project. To promote this development more effectively, it is necessary that different data related to new energies are put into order comprehensively and systematically to be retained as the basic data. Therefore, this paper collects and puts into order the latest published data on cogeneration from among other new energy technology areas, with main regard to system listing, specific introduction examples, subsidy institutions, and how other countries are working on the technologies. Hydroelectric power generation uses up head energy of water by installing power plants along a river from higher location to lower location. Similarly the cogeneration is a kind of multi-stage energy utilization (cascade utilization) system that uses up energy serially from as high oil and natural gas combustion temperature as 1,500 degrees C or higher down to temperature levels used for hot water supply and air conditioning as low as 45 to 50 degrees C. It generates electric power by using a thermal engine, and utilizes waste heat effectively. (NEDO)

  12. Feasibility study of the consolidated nuclear steam system for cogeneration of process steam and electric power for a large oil refinery

    International Nuclear Information System (INIS)

    1982-09-01

    This report evaluates the technical and economic feasibility of a two-unit (1243 MWt each) consolidated nuclear steam system (CNSS), and introduces the integrated light water reactor (ILWR) concept for the supply of process steam and electric power to a typical large oil refinery. The results of the economic analysis are compared to those of a two-unit (1170 MWt each) high temperature gas-cooled reactor (HTGR) plant, of a two-unit (1280 MWt each) conventional coal-fired plant, and of the continued operation of existing oil/natural gas fired cogeneration facilities

  13. Financial considerations affecting implementation of a large multiparty cogeneration project

    Energy Technology Data Exchange (ETDEWEB)

    1979-04-01

    The report identifies problems inhibiting large scale multiparty cogeneration development and suggests means to reconcile the parties' differing interests. The analytical approach adopted for structuring ownership arrangements for a cogeneration project, once engineering studies confirm that the requisite technical advantages exist, is to attempt to resolve three specific issues: (1) identification of the potential participants (industrial customers, the electric utility serving the area, equipment vendors and erectors, design and engineering firms, fuel suppliers and transporters, passive investors, governmental interests, insurance carriers, and others); (2) selection of one or more of the three principal roles which each participant may play: (a) purchaser of project output, (b) provider of other commitments to support financing of the project, and (c) investor in the project; and (3) as to those participants taking an ownership role in the project, deciding whether one participant will act as sole owner or, if joint ownership is selected, deciding which of two structural formats they prefer: (a) an undivided interest approach in which each participant is responsible for and bears the full burden of providing its proportionate share of funding for the project; or (b) a project-entity approach in which each participant owns an interest in a newly organized entity which in turn owns project assets, thereby making the funding of the project the common responsibility of all of the participants.

  14. Desalination of seawater with nuclear power reactors in cogeneration

    International Nuclear Information System (INIS)

    Flores E, R.M.

    2004-01-01

    The growing demand for energy and hydraulic resources for satisfy the domestic, industrial, agricultural activities, etc. has wakened up the interest to carry out concerning investigations to study the diverse technologies guided to increase the available hydraulic resources, as well as to the search of alternatives of electric power generation, economic and socially profitable. In this sense the possible use of the nuclear energy is examined in cogeneration to obtain electricity and drinkable water for desalination of seawater. The technologies are analysed involved in the nuclear cogeneration (desalination technology, nuclear and desalination-nuclear joining) available in the world. At the same time it is exemplified the coupling of a nuclear reactor and a process of hybrid desalination that today in day the adult offers and economic advantages. Finally, the nuclear desalination is presented as a technical and economically viable solution in regions where necessities of drinkable water are had for the urban, agricultural consumption and industrial in great scale and that for local situations it is possible to satisfy it desalinating seawater. (Author)

  15. Impact of cogeneration on integrated resource planning of Turkey

    International Nuclear Information System (INIS)

    Atikol, U.; Gueven, H.

    2003-01-01

    In most developing countries, difficulties in finding sector-specific data on heat rate and power demands make energy planning a hard task. In some countries, although this data is available, it may be four or five years old. In the present work, a new low-cost method is proposed for developing countries aiming at obtaining such data for the industrial sector quickly. Fifty-two textile factories were selected for a survey to represent the industrial sector. The data were processed and used to generate two scenarios of cogeneration applications in the industrial sector; one sized according to the electrical load of the factories, and the other one according to the thermal load. The costs and primary energy requirements of these programs were compared with that of the nuclear alternative. It was found that the most energy efficient and economical option for Turkey was the cogeneration program, the equipment sizing of which was based on the process heat demand of the industrial sector. Turkey would not only save US$ 72.6-billion by deferring the nuclear program, but it will also reduce the total primary energy demand by 11% in 2020

  16. The results of feasibility study of co-generation NPP with innovative VK-300 simplified boiling water reactor

    International Nuclear Information System (INIS)

    Kuznetsov, Yu. N.; Gabaraev, B. A.

    2004-01-01

    The co-generation nuclear power plant (CNPP) producing electricity and district-heating heat is planned to be constructed in Archangelsk Region of Russia. Following the Letter of Intent signed by Governor of Archangelsk region and by Minister of the Russian Federation for atomic energy the feasibility study of the Project has been done. The NPP will be based on the four co-generation nuclear power units with the Russian VK-300 SBWR. The innovative passive VK-300 reactor facility has been designed on the basis of well-established nuclear technologies, proven major components, the operating experience of the prototype VK-50 reactor in RIAR, Dimitrovgrad, and the experience in designing such reactors as SBWR (GE) and SWR-1000 (Siemens). The CNPP's total power is planned to be 1000 MW(e) and district-heating heat production capacity 1600 Gcal /h. A detailed description of the results of the feasibility study is presented in the report. The results of the feasibility study have shown that the Archangelsk CGNP is feasible in terms of engineering, economics and production.(author)

  17. Cogeneration of Electricity and Potable Water Using The International Reactor Innovative And Secure (IRIS) Design

    International Nuclear Information System (INIS)

    Ingersoll, D.T.; Binder, J.L.; Kostin, V.I.; Panov, Y.K.; Polunichev, V.; Ricotti, M.E.; Conti, D.; Alonso, G.

    2004-01-01

    The worldwide demand for potable water has been steadily growing and is projected to accelerate, driven by a continued population growth and industrialization of emerging countries. This growth is reflected in a recent market survey by the World Resources Institute, which shows a doubling in the installed capacity of seawater desalination plants every ten years. The production of desalinated water is energy intensive, requiring approximately 3-6 kWh/m3 of produced desalted water. At current U.S. water use rates, a dedicated 1000 MW power plant for every one million people would be required to meet our water needs with desalted water. Nuclear energy plants are attractive for large scale desalination application. The thermal energy produced in a nuclear plant can provide both electricity and desalted water without the production of greenhouse gases. A particularly attractive option for nuclear desalination is to couple a desalination plant with an advanced, modular, passively safe reactor design. The use of small-to-medium sized nuclear power plants allows for countries with smaller electrical grid needs and infrastructure to add new electrical and water capacity in more appropriate increments and allows countries to consider siting plants at a broader number of distributed locations. To meet these needs, a modified version of the International Reactor Innovative and Secure (IRIS) nuclear power plant design has been developed for the cogeneration of electricity and desalted water. The modular, passively safe features of IRIS make it especially well adapted for this application. Furthermore, several design features of the IRIS reactor will ensure a safe and reliable source of energy and water even for countries with limited nuclear power experience and infrastructure. The IRIS-D design utilizes low-quality steam extracted from the low-pressure turbine to boil seawater in a multi-effect distillation desalination plant. The desalination plant is based on the horizontal

  18. BP Cherry Point Cogeneration Project, Draft Environmental Impact Statement

    Energy Technology Data Exchange (ETDEWEB)

    N/A

    2003-09-19

    BP West Coast Products, LLC (BP or the Applicant) proposes to construct and operate a nominal 720-megawatt (MW), natural-gas-fired, combined-cycle cogeneration facility next to the existing BP Cherry Point Refinery in Whatcom County, Washington. The Applicant also owns and operates the refinery, but the cogeneration facility and the refinery would be operated as separate business units. The cogeneration facility and its ancillary infrastructure would provide steam and 85 MW of electricity to meet the operating needs of the refinery and 635 MW of electrical power for local and regional consumption. The proposed cogeneration facility would be located between Ferndale and Blaine in northwestern Whatcom County, Washington. The Canadian border is approximately 8 miles north of the proposed project site. The Washington State Energy Facility Site Evaluation Council (EFSEC) has jurisdiction over the evaluation of major energy facilities including the proposed project. As such, EFSEC will recommend approval or denial of the proposed cogeneration facility to the governor of Washington after an environmental review. On June 3, 2002, the Applicant filed an Application for Site Certification (ASC No. 2002-01) with EFSEC in accordance with Washington Administrative Code (WAC) 463-42. On April 22, 2003, the Applicant submitted an amended ASC that included, among other things, a change from air to water cooling. With the submission of the ASC and in accordance with the State Environmental Policy Act (SEPA) (WAC 463-47), EFSEC is evaluating the siting of the proposed project and conducting an environmental review with this Environmental Impact Statement (EIS). Because the proposed project requires federal agency approvals and permits, this EIS is intended to meet the requirements under both SEPA and the National Environmental Policy Act (NEPA). The Bonneville Power Administration (Bonneville) and U.S. Army Corps of Engineers (Corps) also will use this EIS as part of their

  19. INNOVATIVE HYBRID GAS/ELECTRIC CHILLER COGENERATION

    Energy Technology Data Exchange (ETDEWEB)

    Todd Kollross; Mike Connolly

    2004-06-30

    Engine-driven chillers are quickly gaining popularity in the market place (increased from 7,000 tons in 1994 to greater than 50,000 tons in 1998) due to their high efficiency, electric peak shaving capability, and overall low operating cost. The product offers attractive economics (5 year pay back or less) in many applications, based on areas cooling requirements and electric pricing structure. When heat is recovered and utilized from the engine, the energy resource efficiency of a natural gas engine-driven chiller is higher than all competing products. As deregulation proceeds, real time pricing rate structures promise high peak demand electric rates, but low off-peak electric rates. An emerging trend with commercial building owners and managers who require air conditioning today is to reduce their operating costs by installing hybrid chiller systems that combine gas and electric units. Hybrid systems not only reduce peak electric demand charges, but also allow customers to level their energy load profiles and select the most economical energy source, gas or electricity, from hour to hour. Until recently, however, all hybrid systems incorporated one or more gas-powered chillers (engine driven and/or absorption) and one or more conventional electric units. Typically, the cooling capacity of hybrid chiller plants ranges from the hundreds to thousands of refrigeration tons, with multiple chillers affording the user a choice of cooling systems. But this flexibility is less of an option for building operators who have limited room for equipment. To address this technology gap, a hybrid chiller was developed by Alturdyne that combines a gas engine, an electric motor and a refrigeration compressor within a single package. However, this product had not been designed to realize the full features and benefits possible by combining an engine, motor/generator and compressor. The purpose of this project is to develop a new hybrid chiller that can (1) reduce end-user energy

  20. Design, parametrization, and pole placement of stabilizing output feedback compensators via injective cogenerator quotient signal modules.

    Science.gov (United States)

    Blumthaler, Ingrid; Oberst, Ulrich

    2012-03-01

    Control design belongs to the most important and difficult tasks of control engineering and has therefore been treated by many prominent researchers and in many textbooks, the systems being generally described by their transfer matrices or by Rosenbrock equations and more recently also as behaviors. Our approach to controller design uses, in addition to the ideas of our predecessors on coprime factorizations of transfer matrices and on the parametrization of stabilizing compensators, a new mathematical technique which enables simpler design and also new theorems in spite of the many outstanding results of the literature: (1) We use an injective cogenerator signal module ℱ over the polynomial algebra [Formula: see text] (F an infinite field), a saturated multiplicatively closed set T of stable polynomials and its quotient ring [Formula: see text] of stable rational functions. This enables the simultaneous treatment of continuous and discrete systems and of all notions of stability, called T-stability. We investigate stabilizing control design by output feedback of input/output (IO) behaviors and study the full feedback IO behavior, especially its autonomous part and not only its transfer matrix. (2) The new technique is characterized by the permanent application of the injective cogenerator quotient signal module [Formula: see text] and of quotient behaviors [Formula: see text] of [Formula: see text]-behaviors B. (3) For the control tasks of tracking, disturbance rejection, model matching, and decoupling and not necessarily proper plants we derive necessary and sufficient conditions for the existence of proper stabilizing compensators with proper and stable closed loop behaviors, parametrize all such compensators as IO behaviors and not only their transfer matrices and give new algorithms for their construction. Moreover we solve the problem of pole placement or spectral assignability for the complete feedback behavior. The properness of the full feedback behavior

  1. District heating and cogeneration in the EU-28: Current situation, potential and proposed energy strategy for its generalisation

    Directory of Open Access Journals (Sweden)

    Enrique Rosales-Asensio

    2016-10-01

    Full Text Available Yearly, EU-28 conventional thermal generating plants reject a greater amount of energy than what ultimately is utilised by residential and commercial loads for heating and hot water. If this waste heat were to be used through district heating networks, given a previous energy valorisation, there would be a noticeable decrease in imported fossil fuels for heating. As a consequence, benefits in the form of an energy efficiency increase, an energy security improvement, and a minimisation of emitted greenhouse gases would occur. Given that it is not expected for heat demand to decrease significantly in the medium term, district heating networks show the greatest potential for the development of cogeneration. However, to make this happen, some barriers that are far from being technological but are mostly institutional and financial need to be removed. The purpose of this review is to provide information on the potential of using waste heat from conventional thermal power plants (subsequently converted into cogeneration plants in district heating networks located in the EU-28. For this, a preliminary assessment is conducted in order to show an estimate of the cost of adopting an energy strategy in which district heating networks are a major player of the energy mix. From this assessment, it is possible to see that even though the energy strategy proposed in this paper, which is based on a dramatic increase in the joint use of district heating networks and cogeneration, is capital-intensive and would require an annual investment of roughly 300 billion euros, its adoption would result in a reduction of yearly fuel expenses in the order of 100 billion euros and a shortening of about 15% of the total final energy consumption, which makes it of paramount interest as an enabler of the legal basis of the “Secure, Clean and Efficient Energy” future enacted by the EU-28 Horizon 2020.

  2. Methods of Assessing the Efficiency of Cogeneration of Electricity and Heat

    Directory of Open Access Journals (Sweden)

    Postolaty V.M.

    2015-12-01

    Full Text Available A method that allows calculating the primary energy savings of fuel cogeneration of electricity and heat as compared to separate methods produce the same amount of these types of energy. An analytic expression relating the energy consumption of fuel for production of electricity and heat, taking into account the efficiency with the technologies of production of electricity and heat separately, and the total efficiency when these types of energy are in cogeneration. The results are illustrated by the example. Basing on these results it is recommended to amend the Law on thermal energy and cogeneration of electricity and heat concerning the methodologies for calculating performance of these types of energy cogeneration.

  3. Development of a Robust, Highly Efficient Oxygen-Carbon Monoxide Cogeneration System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This small business innovation research is intended to develop a long-life, highly efficient O2-CO cogeneration system to support NASA's endeavors to pursue...

  4. Development of a Robust, Highly Efficient Oxygen-Carbon Monoxide Cogeneration System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This small business innovation research is intended to develop a long-life, highly efficient O2-CO cogeneration system to support NASA's endeavors to pursue...

  5. Micro-cogeneration units based on Stirling engine for heating and their real operation

    Science.gov (United States)

    Čierny, Jaroslav; Patsch, Marek

    2014-08-01

    This article was deal with micro-cogeneration units based on Stirling engine. We watched problematic of real working Stirling engine. The article also contain hookup of unit constructed at University of Zilina.

  6. Development of a Robust, Highly Efficient Oxygen-Carbon Monoxide Cogeneration System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This small business innovation research is intended to develop a long-life, highly efficient O2-CO cogeneration system to support NASA's endeavors to pursue...

  7. Comparison of Integrated Gasifier-Combined Cycle and AFB-steam turbine systems for industrial cogeneration

    Science.gov (United States)

    Nainiger, J. J.; Abbott, J. M.; Burns, R. K.

    1981-01-01

    In the cogeneration technology alternatives study (CTAS) a number of advanced coal fired systems were examined and systems using a integrated coal gasifier IGCC or a fluid bed combustor AFB were found to yield attractive cogeneration results in industrial cogeneration applications. A range of site requirements and cogeneration sizing strategies using ground rules based on CTAS were used in comparing an IGCC and an AFB. The effect of time variations in site requirements and the sensitivity to fuel and electricity price assumptions are examined. The economic alternatives of industrial or utility ownership are also considered. The results indicate that the IGCC system has potentially higher fuel and emission savings and could be an attractive option for utility ownership. The AFB steam turbine system has a potentially higher return on investment and could be attractive assuming industrial ownership.

  8. Thermodynamic study of residual heat from a high temperature nuclear reactor to analyze its viability in cogeneration processes; Estudio termodinamico del calor residual de un reactor nuclear de alta temperatura para analizar su viabilidad en procesos de cogeneracion

    Energy Technology Data Exchange (ETDEWEB)

    Santillan R, A.; Valle H, J.; Escalante, J. A., E-mail: santillanaura@gmail.com [Universidad Politecnica Metropolitana de Hidalgo, Boulevard acceso a Tolcayuca 1009, Ex-Hacienda San Javier, 43860 Tolcayuca, Hidalgo (Mexico)

    2015-09-15

    In this paper the thermodynamic study of a nuclear power plant of high temperature at gas turbine (GTHTR300) is presented for estimating the exploitable waste heat in a process of desalination of seawater. One of the most studied and viable sustainable energy for the production of electricity, without the emission of greenhouse gases, is the nuclear energy. The fourth generation nuclear power plants have greater advantages than those currently installed plants; these advantages have to do with security, increased efficiencies and feasibility to be coupled to electrical cogeneration processes. In this paper the thermodynamic study of a nuclear power plant type GTHTR300 is realized, which is selected by greater efficiencies and have optimal conditions for use in electrical cogeneration processes due to high operating temperatures, which are between 700 and 950 degrees Celsius. The aim of the study is to determine the heat losses and the work done at each stage of the system, determining where they are the greatest losses and analyzing in that processes can be taken advantage. Based on the study was appointed that most of the energy losses are in form of heat in the coolers and usually this is emitted into the atmosphere without being used. From the results a process of desalination of seawater as electrical cogeneration process is proposed. This paper contains a brief description of the operation of the nuclear power plant, focusing on operation conditions and thermodynamic characteristics for the implementation of electrical cogeneration process, a thermodynamic analysis based on mass and energy balance was developed. The results allow quantifying the losses of thermal energy and determining the optimal section for coupling of the reactor with the desalination process, seeking to have a great overall efficiency. (Author)

  9. Project considerations and design of systems for wheeling cogenerated power

    Energy Technology Data Exchange (ETDEWEB)

    Tessmer, R.G. Jr.; Boyle, J.R.; Fish, J.H. III; Martin, W.A.

    1994-08-01

    Wheeling electric power, the transmission of electricity not owned by an electric utility over its transmission lines, is a term not generally recognized outside the electric utility industry. Investigation of the term`s origin is intriguing. For centuries, wheel has been used to describe an entire machine, not just individual wheels within a machine. Thus we have waterwheel, spinning wheel, potter`s wheel and, for an automobile, wheels. Wheel as a verb connotes transmission or modification of forces and motion in machinery. With the advent of an understanding of electricity, use of the word wheel was extended to be transmission of electric power as well as mechanical power. Today, use of the term wheeling electric power is restricted to utility transmission of power that it doesn`t own. Cogeneration refers to simultaneous production of electric and thermal power from an energy source. This is more efficient than separate production of electricity and thermal power and, in many instances, less expensive.

  10. How to calculate avoided costs in a cogeneration cycle

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, H.

    1985-09-01

    When calculating the value of heat recovered from engine exhaust in a cogeneration cycle, some energy managers and engineers use the 3413 standard of evaluation: that is, that 3413 Btu of recovered engine exhaust heat has a financial value equivalent to the cost of one kilowatt hour of utility-purchased electricity. The standard establishing 3413 Btu as the equivalent of one kilowatt hour is valid where the heat output from a 1000-watt electric resistance heater is used to add 3413 Btu from electric resistance heat to 23.70 pounds of water in one hour. The temperature of that amount of water will, in one hour, increase 144/sup 0/F (3413/23.70 = 144). To avoid the latent heat range, the starting temperature of the water must not be greater than 67/sup 0/F at sea level. Unless the 3413 standard is understood, it can lead to expensive mistakes in projected avoided costs.

  11. Advanced coal-fueled industrial cogeneration gas turbine system

    Energy Technology Data Exchange (ETDEWEB)

    LeCren, R.T.; Cowell, L.H.; Galica, M.A.; Stephenson, M.D.; Wen, C.S.

    1991-07-01

    Advances in coal-fueled gas turbine technology over the past few years, together with recent DOE-METC sponsored studies, have served to provide new optimism that the problems demonstrated in the past can be economically resolved and that the coal-fueled gas turbine can ultimately be the preferred system in appropriate market application sectors. The objective of the Solar/METC program is to prove the technical, economic, and environmental feasibility of a coal-fired gas turbine for cogeneration applications through tests of a Centaur Type H engine system operated on coal fuel throughout the engine design operating range. The five-year program consists of three phases, namely: (1) system description; (2) component development; (3) prototype system verification. A successful conclusion to the program will initiate a continuation of the commercialization plan through extended field demonstration runs.

  12. Utilization of cogenerated power and heat in market gardens. Anvendelse af kraftvarme i gartnerier; Rapport 2. Effektudjaevning. Del 1: Graenser for flowvariationer i nettet. Anvendelse af nettet som buffer

    Energy Technology Data Exchange (ETDEWEB)

    1987-11-01

    The overall aim was to discover special problems related to heat and power supplies to the market gardening industry, to achieve optimization of the cogeneration plants providing heat to individual market gardens, and to promote the use of cogeneration plants throughout this industry. In greenhouses especially, outside weather conditions, and the special demands of plant and vegetable growth, strongly influence the amount, and variations in the amount, of heat needed from outside sources, and the aim of this project was to work towards an adjustment of flow variations within the distribution network. Flow gradients were also examined in addition to possible speed of adjustments in the flow. Various methods of levelling variations in consumption by the control of inlet temperature were investigated (using the piping system as a ''buffer''). Data on measurements of the flow to market garden buildings in Selleberg (Denmark) were analysed in order to record typical flow variations for this type of consumer. Methods and results of these analyses are presented. It was concluded that the special consumption patterns related to horticulture do not give significant pressure loads in the network. But there are resulting greater demands on the regulation of the system's pumps and adjustment of production at the cogeneration plant. (AB).

  13. Metamorphoses of cogeneration-based district heating in Romania: A case study

    International Nuclear Information System (INIS)

    Iacobescu, Flavius; Badescu, Viorel

    2011-01-01

    The paper presents the birth and evolution of the cogeneration-based district heating (DH) system in a medium size city in Romania (Targoviste). The evolution of the industrialization degree was the main factor which controlled the population growth and led to a continuous reconfiguration of the DH system. The DH system assisted by cogeneration emerged as a solution in a certain phase of the demographic development of the city. The political and social changes occurring in Romania after 1990 have had important negative consequences on the DH systems in small towns. In Targoviste the DH system survived but in 2001 the solution based on cogeneration became economically inefficient, due to the low technical quality of the existing equipment and the low gas prices, to the procedure of setting the DH tariffs and the service cost at consumer's level and to some bureaucratic problems. Energy policy measures taken at national and local levels in 2003 and 2005 led to the re-establishment of the cogeneration-based district heating in 2005. However, a different technical solution has been adopted. Details about the present (2009) cogeneration-based DH system in Targoviste are presented together with several technical and economical indicators. The main conclusion is that by a proper amendment of the technical solutions, cogeneration could be a viable solution for DH even in case of abrupt social and demographic changes, such as those occurring in Romania after 1990. - Research Highlights: →Birth and evolution of the cogeneration-based district heating system in a medium size city. →The industrialization degree is the main factor which controlled the reconfiguration of the district heating system. →Each stage of the evolution of district heating system has been a technological leap. →Cogeneration is a solution for district heating even in case of abrupt social changes.

  14. The marginal costs like reference for the decision of electric energy cogeneration in Brazil

    International Nuclear Information System (INIS)

    Silva, D.B. da; Eduardo, J.H.B.P.

    1987-01-01

    The electric cogeneration question, in a form of optimal utilization of high quality chemical energy in some industrial processes, or a form of employment of any others feedstocks, can be discussed on economics view, with the marginal costs reference, actually in implantation in Brazilian Electrical Sector. In this article, some ideas are presented about the mentioned discussion, in the Brazilian Electric Sector ambient, including analysis of laws and proposed directions for its modifications, looking for the cogeneration activity development in Brazil. (author)

  15. Report on the installations of cogeneration under obligation to buy; Rapport sur les installations de cogeneration sous obligation d'achat

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-01-15

    Facing the problem of the climatic change and the increase of the fossil energies prices, the government policy of the cogeneration development follows many objectives. Among these objectives it is necessary of implement a new tariff of obligation to buy of the electricity from cogeneration and allow the existing installations to reaffirm their obligation to buy contract. The first part of this report defines the necessary conditions to better use the ecological and economical interest of the natural gas cogeneration and shows that these conditions are not favorable in France. The second part preconizes to modify the actual tariff device in order to maintain the existing park to 2015 in acceptable economical and ecological conditions. (A.L.B.)

  16. Evaluating Interventions in the U.S. Electricity System: Assessments of Energy Efficiency, Renewable Energy, and Small-Scale Cogeneration

    Science.gov (United States)

    Siler-Evans, Kyle

    There is growing interest in reducing the environmental and human-health impacts resulting from electricity generation. Renewable energy, energy efficiency, and energy conservation are all commonly suggested solutions. Such interventions may provide health and environmental benefits by displacing emissions from conventional power plants. However, the generation mix varies considerably from region to region and emissions vary by the type and age of a generator. Thus, the benefits of an intervention will depend on the specific generators that are displaced, which vary depending on the timing and location of the intervention. Marginal emissions factors (MEFs) give a consistent measure of the avoided emissions per megawatt-hour of displaced electricity, which can be used to evaluate the change in emissions resulting from a variety of interventions. This thesis presents the first systematic calculation of MEFs for the U.S. electricity system. Using regressions of hourly generation and emissions data from 2006 through 2011, I estimate regional MEFs for CO2, NO x, and SO2, as well as the share of marginal generation from coal-, gas-, and oil-fired generators. This work highlights significant regional differences in the emissions benefits of displacing a unit of electricity: compared to the West, displacing one megawatt-hour of electricity in the Midwest is expected to avoid roughly 70% more CO2, 12 times more SO 2, and 3 times more NOx emissions. I go on to explore regional variations in the performance of wind turbines and solar panels, where performance is measured relative to three objectives: energy production, avoided CO2 emissions, and avoided health and environmental damages from criteria pollutants. For 22 regions of the United States, I use regressions of historic emissions and generation data to estimate marginal impact factors, a measure of the avoided health and environmental damages per megawatt-hour of displaced electricity. Marginal impact factors are used

  17. Dynamic performance assessment of a residential building-integrated cogeneration system under different boundary conditions. Part II: Environmental and economic analyses

    International Nuclear Information System (INIS)

    Rosato, Antonio; Sibilio, Sergio; Scorpio, Michelangelo

    2014-01-01

    Highlights: • A building-integrated micro-cogeneration system was dynamically simulated. • Simulation data were analyzed from both environmental and economic point of views. • The proposed system was compared with a conventional supply system. • The proposed system reduces the environmental impact under heat-led operation. • The proposed system reduces the operating costs whatever the control logic is. - Abstract: This work examines the performance of a residential building-integrated micro-cogeneration system during the winter by means of a whole building simulation software. The cogeneration unit was coupled with a multi-family house composed of three floors, compliant with the transmittance values of both walls and windows suggested by the Italian Law; a stratified combined tank for both heating purposes and domestic hot water production was also used for storing heat. Simulations were performed considering the transient nature of the building and occupant driven loads as well as the part-load characteristics of the cogeneration unit. This system was described in detail and analyzed from an energy point of view in the companion paper. In this paper the simulation results were evaluated in terms of both carbon dioxide equivalent emissions and operating costs; detailed analyses were performed in order to estimate the influence of the most significant boundary conditions on both environmental and economic performance of the proposed system: in particular, three volumes of the hot water storage, four climatic zones corresponding to four Italian cities, two electric demand profiles, as well as two control strategies micro-cogeneration unit were considered. The assessment of environmental impact was performed by using the standard emission factors approach, neglecting the effects of local pollutants. The operating costs due to both natural gas and electric energy consumption were evaluated in detail, whereas both the capital and maintenance costs were

  18. Experimental and numerical analysis of the combustor for a cogeneration system based on the aluminum/water reaction

    International Nuclear Information System (INIS)

    Milani, Massimo; Montorsi, Luca; Paltrinieri, Fabrizio; Stefani, Matteo

    2014-01-01

    Highlights: • Aluminum reaction with water is studied as a technology for hydrogen production. • A test rig is developed for the analysis of aluminum/water reaction. • The system is the core component of a cogeneration plant for hydrogen/power production. • The interaction of liquid aluminum jet and water steam stream is investigated. • The main capabilities of the injection system are assessed. - Abstract: The paper focuses on the design of the experimental apparatus aimed at analyzing the performance of the combustion chamber of a cogeneration system based on the reaction of liquid aluminum and water steam. The cogeneration system exploits the heat released by the oxidation of aluminum with water for super-heating the vapor of a steam cycle and simultaneously producing hydrogen. The only by-product is alumina, which in a closed loop can be recycled back and transformed again into aluminum. Therefore, aluminum is used as an energy carrier to transport the energy from the alumina reduction plant to the location of the proposed system. The water is also used in a closed loop since the amount of water produced employing the hydrogen obtained by the proposed system corresponds to the oxidizing water for the Al/H 2 O reaction. This study investigates the combustor where the liquid aluminum–steam reaction takes place. In particular, the design of the combustion chamber and the interaction between the liquid aluminum jet and the water steam flow are evaluated using a numerical and an experimental approach. The test rig is specifically designed for the analysis of the liquid aluminum injection in a slightly super-heated steam stream. The first experiments are carried out to verify the correct behavior of the test rig. Thermography is employed to qualitatively assess the steam entrainment of the liquid aluminum jet. Finally, the experimental measurements are compared with the multi-dimension multi-phase flow simulations in order to estimate the influence of

  19. The electricity cogeneration in sugar mills and alcohol and the reduction of emissions of greenhouse gases

    International Nuclear Information System (INIS)

    Valdés Delgado, Antonio

    2015-01-01

    Electric power in Cuba currently produces -in high proportion- plants employing fossil fuel. The price of fossil fuels and the negative influence on the environment by emissions of greenhouse gases, has indicated the need to develop other energy sources. Biomass sugarcane provides ample opportunities to produce this energy with positive economic and environmental results. The technological process for the production of sugar requires the use of mechanical energy, low power consumption compared to thermal energy requirements and their use at low pressures determine the possibility of implementing a cogeneration system of mechanical, thermal and electrical energy. The power consumption for the driving equipment of a factory is about 15-30 kw-kr / ton rod. The amount of electrical energy generated in a sugar cane factory is sufficient to meet their own needs, being able to obtain an additional amount for supply to the public network and meet the needs of other productions as is alcohol. Agricultural crop residues (RAC) and sugarcane bagasse and a liquid fuel: alcohol and gaseous fuel: different energy possibilities derived from the sugar industry reflected in the disposal of solid fuels such as is the biogas. The preparation of solid, liquid and gaseous fuels from sugar and alcohol production avoids the use of fossil fuels such as gasoline and fuel oil and gas enables not be sent into the atmosphere that impact on the greenhouse effect. (full text)

  20. Steam generation unit in a simple version of biomass based small cogeneration unit

    Directory of Open Access Journals (Sweden)

    Sornek Krzysztof

    2014-01-01

    Full Text Available The organic Rankine cycle (ORC is a very promising process for the conversion of low or medium temperature heat to electricity in small and micro scale biomass powered systems. Classic ORC is analogous to Clausius–Rankine cycle in a steam power plant, but instead of water it uses low boiling, organic working fluids. Seeking energy and economical optimization of biomass-based ORC systems, we have proposed some modifications e.g. in low boiling fluid circuit construction. Due to the fact that the operation of a micro steam turbine is rather inefficient from the technical and economic point of view, a specially modified air compressor can be used as a steam piston engine. Such engine should be designed to work at low pressure of the working medium. Studies regarding the first version of the prototype installation were focused on the confirmation of applicability of a straw boiler in the prototype ORC power system. The results of the previous studies and the studies described in the paper (on the new cogeneration unit confirmed the high potential of the developed solution. Of course, many further studies have to be carried out.

  1. Fuel cell technology for cogeneration systems. Symposium. Proceedings; Brennstoffzellen - Technologie fuer Blockheizkraftwerke. Symposium. Dokumentation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This proceedings volume contains 11 papers on the following subject: Competence network 'Fuel Cells' in Nordrhein-Westfalen (D. Stolten, Juelich Research Center); Fuel cells in stationary applications (B. Hoehlein, Juelich Research Center); Functional principles of energy conversion in fuel cells (W. Schnurnberger, DLR); Low-temperature fuel cells AFC, PEMFC, PAFC (M. Waidhas, Siemens); High-temperature fuel cells - SOFC, MCFC (D. Stolten); Power plant options - natural gas, hydrogen, etc. (R. Wurster, Ludwig-Boelkow-Systemtechnik); Fuel cell supply (A. Heizel, ISE); Hydrogen-fuelled cogeneration units (G. Gummert Hamburg Gas Consult); SOFC high-temperature fuel cells for domestic power supply (R. Diethelm, Sulzer-Hexis); PEFC low-temperature fuel cells for domestic power supply (K. Klinder, Vaillant); Fuel cells, a chance for local utilities (B. Vogel, WINGAS). [German] Dieser Tagungsband enthaelt 11 Beitraege zu folgenden Themen: Kompetenznetzwerk Brennstoffzelle in NRW (D. Stolten, Forschungszentrum Juelich); Brennstoffzellen in der stationaeren Anwendung (B. Hoehlein, Forschungszentrum Juelich); Funktionsprinzipien der Energieumwandlung in Brennstoffzellen (W. Schnurnberger, DLR); Niedertemperaturbrennstoffzellen - AFC, PEMFC, PAFC (M. Waidhas, Siemens); Hochtemperaturbrennstoffzellen - SOFC, MCFC (D. Stolten); Kraftstoffoptionen- Erdgas, Wasserstoff u.a. (R. Wurster, Ludwig-Boelkow-Systemtechnik); Brennstoffbereitstellung (A. Heinzel, ISE); Wasserstoffbetriebene BHKW (G. Gummert Hamburg Gas Consult); Hochtemperaturbrennstoffzelle SOFC fuer die Hausenergieversorgung (R. Diethelm, Sulzer-Hexis); Niedertemperaturbrennstoffzelle PEFC fuer die Hausenergieversorgung (K. Klinder, Vaillant); Brennstoffzelle als Chance fuer lokale EVUs (B. Vogel, WINGAS).

  2. Opportunities for the operation of the Comision Federal de Electricidad`s fossil fuel power plant stations eventually to be retired as cogeneration units; Oportunidades de operar las centrales termoelectricas de la Comision Federal de Electricidad, eventualmente retirables como unidades de cogeneracion

    Energy Technology Data Exchange (ETDEWEB)

    Buendia Dominguez, E. H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Merlos Rueda, R. M. [Programa de Ahorro de Energia para el Sector Electrico, Mexico, D. F. (Mexico)

    1995-12-31

    The Programa de Ahorro de Energia para el Sector Electrico (PAESE) (Program for Energy Conservation for the Electric Sector) in collaboration with the Instituto de Investigaciones Electricas (IIE), decided to evaluate technically and economically the possibilities of operating the Comision Federal de Electricidad`s Thermoelectric Power Stations (TPS), eventually to be retired as cogeneration units in supplying thermal energy to industry. The study was focussed to the Monterrey and San Jeronimo Power Stations, determining in a first stage, the optimum radius for handling and transporting steam and/or hot water and so to define the industries that potentially could obtain heat energy from the TPS, in this stage the thermal needs of the evaluated industries were determined (pressure, temperature and flow). In a second stage, the different arrangements to be made to operate the selected TPS, so as to be in position of satisfying such thermal energy demands were evaluated. This paper presents the results of this study. [Espanol] El Programa de Ahorro de Energia para el Sector Electrico (PAESE), en colaboracion con el Instituto de Investigaciones Electricas, decidieron evaluar tecnica y economicamente las posibilidades de operar las centrales termoelectricas (CT`s) de la Comision Federal de Electricidad, eventualmente retirables, como unidades de cogeneracion al ofrecer calor a la industria. El estudio se enfoco en las centrales de Monterrey y San Jeronimo, determinado en una primera etapa el radio optimo para el manejo y transporte de vapor y/o agua caliente y asi definir a las industrias que potencialmente podrian recibir calor de las CT`s, en esta etapa se determinaron las necesidades termicas de las industrias evaluadas (presion, temperatura y flujo). En una segunda etapa se evaluo los diferentes arreglos para operar las CT`s seleccionadas para que pudieran satisfacer dichas demandas termicas. En este trabajo se presentaron los resultados de dicho estudio.

  3. Technical and economic analysis of a gas turbine/absorption cycle cogeneration system in the Brazilian Amazon; Analise tecnico-economica da cogeracao utilizando turbina a gas e ciclo de refrigeracao por absorcao na Amazonia

    Energy Technology Data Exchange (ETDEWEB)

    Sales, Leandro da Silva; Carvalho, Ricardo Dias Martins de; Venturini, Osvaldo Jose [Universidade Federal de Itajuba (UNIFEI), MG (Brazil)], e-mail: leandro8746@hotmail.com, e-mail: martins@unifei.edu.br, e-mail: osvaldo@unifei.edu.br

    2006-07-01

    The generation and distribution of electricity in the Brazilian Amazon are faced with a number of difficulties, spanning from management aspects to technical issues. These are thermal power plants and the high costs of fuel (including distribution) and maintenance make them unprofitable, often requiring government subsidies. On the other hand, there is a shortage of ice for food preservation in the Amazonian market. In this context, cogeneration could help improve the plants overall efficiency and reduce costs. The proposed paper carries out a technical and economic analysis of a gas turbine and absorption refrigeration cycle cogeneration system supposed located along the Coari-Manaus natural gas pipeline. Actual electricity demand, ice consumption, and weather data for one of the cities to be served by the pipeline are used in the analysis. The gas turbine operation was simulated using Gate Cycle software; the exhaust gases temperature and flow rate output were in turn used for the simulation of a single stage aqua-ammonia refrigeration (AAR) cycle employing Cycle Tempo software. The thermodynamic simulation of the AAR cycle made it possible to determine the optimal temperature at the generator outlet in order to maximize the refrigeration capacity. For the economic analysis, the electricity and ice production costs were carefully determined and local market sales values for both were used. Then, assuming electrical parity and an electricity demand profile typical of the region the annual plant profit was determined. On the assumption that the cogeneration plant could be exempted from the ICMS tax throughout the investment recovery time, the payback period was 7.8 and 6.9 years for capacity factors of 0.572 and 0.614, respectively. In case there is no ICMS tax exemption, the payback period is 13.0 years, making the cogeneration investment not viable economically. (author)

  4. Decision making in cogeneration systems of electric energy: a case study in the sugar-alcohol sector from Mato Grosso do Sul, Brazil; Tomada de decisao em sistemas de cogeracao de energia eletrica: um estudo de caso do setor sucroalcooleiro de Mato Grosso do Sul

    Energy Technology Data Exchange (ETDEWEB)

    Silva, P.P. [Agencia Estadual de Regulacao de Servicos Publicos de Mato Grosso do Sul (AGEPAN), Campo Grande, MS (Brazil); Ortega, J.M. [Universidade Federal de Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil)

    2009-07-01

    This paper presents a tool to determine the influence of the regulatory aspects in the decision making related to the power surpluses production by cogeneration, from the sugar cane bagasse in the sugar and alcohol plants in the state of Mato Grosso do Sul, Brazil. The tool was developed from the identification, within the regulatory aspects, of the determinant conditions (interest variables) applied to the modelling of the cogeneration system in a computational environment. The applied technique was the System Dynamic, implemented through the software Powersim. It were identified and understood the various causal relations of the events related to the power cogeneration and applied in the dynamic simulation of the business, and of the interactive processes that influence its viability. The obtained simulation using the tool allowed the identification, of various investment scenarios, and the main influences of the regulatory aspects in the decision making of the investor.

  5. Local sharing of cogeneration energy through individually prioritized controls for increased on-site energy utilization

    International Nuclear Information System (INIS)

    Hirvonen, Janne; Kayo, Genku; Hasan, Ala; Sirén, Kai

    2014-01-01

    Highlights: • Sharing of surplus heat and electricity produced by CHP plants in different types of buildings. • Individually prioritized control of CHP plants with direct local sharing and minimal storage capacity. • Energy sharing reduced primary energy consumption by 1–9% with biogas. • Excess energy minimized by thermal tracking. - Abstract: All over the world, including Japan, there are targets to decrease building energy consumption and increase renewable energy utilization. Combined heat and power (CHP) plants increase energy efficiency and are becoming popular in Japan. CHP plants produce both heat and power simultaneously, but there is not always a need for both. A cluster of several different buildings can increase total efficiency and reduce primary energy (PE) consumption by sharing excess heat and electricity between neighboring buildings. If the generated energy comes from renewable sources, energy sharing makes it easier to reach the net zero energy balance. By adjusting CHP sizes and operation patterns, the wasted heat and primary energy consumption can be minimized. Energy sharing has been explored in situations with identical buildings and centrally administered energy systems before, but not with different building types with separate systems. In this study, a cluster of Japanese office and residential buildings were combined to allow heat and electricity sharing based on cogeneration, using individually prioritized control (IPC) systems. TRNSYS simulation was used to match energy generation with pregenerated demand profiles. Absorption cooling was utilized to increase the benefits of local heat generation. Different CHP operation modes and plant sizes were tested. The benefit of surplus energy sharing depends on the CHP capacities and the fuel type. When using biogas, larger CHP plants provided lower total primary energy consumption, in the most extreme case lowering it by 71%, compared to the conventional case. Using natural gas

  6. Comparative evaluation of hybrid systems of natural gas cogeneration and sugar cane bagasse; Avaliacao comparativa de sistemas hibridos de cogeracao a gas natutral e bagaco de cana

    Energy Technology Data Exchange (ETDEWEB)

    Zamboni, Leonardo Moneci; Tribess, Arlindo [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: leonardo.zamboni@poli.usp.br; atribess@usp.br

    2006-07-01

    The consumption of electricity in Brazil and mainly in the State of Sao Paulo is increasing gradually. On the other hand, the hydraulic potential is practically exhausted and the government has no resources for such new investments. One solution is the construction of thermo electrical plants with the use of the natural gas and sugar cane bagasse. The natural gas has the advantage of being available in great amount and less pollutant. And the sugar cane bagasse, besides being a by-product of low value, does not cause a global pollution. The work consists of the determination of the best option considering criterion of minimum cost for kWh of energy produced. For such, thermo economic analysis with electricity and steam production costs evaluation in exergetic basis, was accomplished. In the evaluations the consumption of natural gas and the costs of the sugar cane bagasse were varied. The results show that the cogeneration plant with combined cycle using natural gas and burning sugar cane bagasse in the recovery boiler presents the smallest cost of electricity and steam generation (even not being the cycle with larger exergetic efficiency). On the other hand, for a natural gas cost of 140 US$/t and a cost of sugar cane bagasse superior to 10,50 US$/t the cogeneration plant with combined cycle using only natural gas (and, therefore not burning or gasifying sugar cane bagasse) presented the smallest cost of electricity and steam generation. (author)

  7. Cost-benefit analysis for combined heat and power plant

    International Nuclear Information System (INIS)

    Sazdovski, Ace; Fushtikj, Vangel

    2004-01-01

    The paper presents a methodology and practical application of Cost-Benefit Analysis for Combined Heat and Power Plant (Cogeneration facility). Methodology include up-to-date and real data for cogeneration plant in accordance with the trends ill development of the CHP technology. As a case study a CHP plant that could be built-up in Republic of Macedonia is analyzed. The main economic parameters for project evaluation, such as NPV and IRR are calculated for a number of possible scenarios. The analyze present the economic outputs that could be used as a decision for CHP project acceptance for investment. (Author)

  8. DENINT power plant cost benefit analysis code: Analysis of methane fuelled power plant/district heating system

    International Nuclear Information System (INIS)

    Cincotti, V.; D'Andrea, A.

    1989-07-01

    The DENINT power plant cost benefit analysis code takes into consideration, not only power production costs at the generator terminals, but also, in the case of cogeneration, the costs of the fuel supply and heat and power distribution systems which depend greatly on the location of the plant. The code is able to allow comparisons of alternatives with varying annual operation hours, fuel cost increases, and different types of fossil fuels and production systems. For illustrative purposes, this paper examines two methane fired cogeneration plant/district heating alternatives

  9. Higher-capacity lithium ion battery chemistries for improved residential energy storage with micro-cogeneration

    International Nuclear Information System (INIS)

    Darcovich, K.; Henquin, E.R.; Kenney, B.; Davidson, I.J.; Saldanha, N.; Beausoleil-Morrison, I.

    2013-01-01

    Highlights: • Characterized two novel high capacity electrode materials for Li-ion batteries. • A numerical discharge model was run to characterize Li-ion cell behavior. • Engineering model of Li-ion battery pack developed from cell fundamentals. • ESP-r model integrated micro-cogeneration and high capacity Li-ion storage. • Higher capacity batteries shown to improve micro-cogeneration systems. - Abstract: Combined heat and power on a residential scale, also known as micro-cogeneration, is currently gaining traction as an energy savings practice. The configuration of micro-cogeneration systems is highly variable, as local climate, energy supply, energy market and the feasibility of including renewable type components such as wind turbines or photovoltaic panels are all factors. Large-scale lithium ion batteries for electrical storage in this context can provide cost savings, operational flexibility, and reduced stress on the distribution grid as well as a degree of contingency for installations relying upon unsteady renewables. Concurrently, significant advances in component materials used to make lithium ion cells offer performance improvements in terms of power output, energy capacity, robustness and longevity, thereby enhancing their prospective utility in residential micro-cogeneration installations. The present study evaluates annual residential energy use for a typical Canadian home connected to the electrical grid, equipped with a micro-cogeneration system consisting of a Stirling engine for supplying heat and power, coupled with a nominal 2 kW/6 kW h lithium ion battery. Two novel battery cathode chemistries, one a new Li–NCA material, the other a high voltage Ni-doped lithium manganate, are compared in the residential micro-cogeneration context with a system equipped with the presently conventional LiMn 2 O 4 spinel-type battery

  10. Distributed cogeneration for commercial buildings: Can we make the economics work?

    International Nuclear Information System (INIS)

    Siler-Evans, Kyle; Morgan, M. Granger; Azevedo, Inês Lima

    2012-01-01

    Although the benefits of distributed cogeneration are widely cited, adoption has been slow in the United States. Adoption could be encouraged by making cogeneration more economically attractive, either by increasing the expected returns or decreasing the risks of such investments. We evaluate the expected returns from demand response, capacity markets, regulation markets, accelerated depreciation, pricing CO 2 emissions, and net metering. We find that (1) there is an incentive to overcommit in the capacity market due to lenient non-response penalties, (2) there is significant revenue potential in the regulation market, though demand-side resources are yet to participate, (3) a price on CO 2 emissions will make cogeneration more attractive relative to conventional, utility-supplied energy, and (4) accelerated depreciation is an easy and effective mechanism for improving the economics of cogeneration. We go on to argue that uncertainty in fuel and electricity prices present a significant risk to cogeneration projects, and we evaluate the effectiveness of feed-in tariffs at mitigating these risks. We find that guaranteeing a fixed electricity payment is not effective. A two-part feed-in tariff, with an annual capacity payment and an energy payment that adjusts with fuel costs, can eliminate energy-price risks. - Highlights: ► A case study is used to evaluate strategies for improving the economics of cogeneration. ► Strategies include demand response, capacity and regulation markets, net metering. ► Volatile energy prices present a significant risk to cogeneration projects. ► We explore mitigating energy-price risks with feed-in tariffs.

  11. ANTARES application for cogeneration: oil recovery from bitumen and upgrading

    Energy Technology Data Exchange (ETDEWEB)

    Lecomte, Michel [FRAMATOME ANP SAS (France); Gosset, Jerome [Ecole des Mines de Paris (France); Younsi, Houria [ENSEM, Nancy (France)

    2006-07-01

    Full text of publication follows: High Temperature Reactors have raised a lot of interest in the past few years because of their specific passive safety characteristics and their potential for high energy conversion efficiency. While most works emphasize the electricity production, HTRs have unique and broad range capabilities in process heat production. Recent interest for their very high temperature capabilities emphasize their use for hydrogen production through advanced high temperature processes, whether electrolytic or chemical. These are in the development stage for long term availability. Meanwhile, HTRs are quite capable to bring highly efficient cogeneration processes to fruition in a short term for low and medium temperature needs. ANTARES, the AREVA HTR development program, is based on an 850 deg. C nuclear heat source linked to a combined cycle power conversion system which brings high efficiency, over 46 %, in its electricity production version without any major new development except an Intermediate Heat exchanger (IHX)[1]. Description of the actual work A particular feature of this design is to be readily adaptable to low and medium process heat delivery, up to 550 deg. C, while still producing a significant amount of electricity. This design is therefore particularly amenable to cogeneration of process heat and electricity. The present paper describes industrial heat delivered at 100 Bar and 310 deg. C together with electricity. Such process heat production is typical of the needs for bitumen recovery from oil sands using the SAGD process. In order to optimize the process, heat must be removed from the cycle at the best location. The computer program THERMOPTIM, developed at the Ecole des Mines de Paris [2], has been designed specifically for that purpose and has been used to calculate the new performance and to help locate the process heat extraction points. Results With such optimization, up to 80% of the nuclear heat is converted into useful

  12. Cost-benefit analysis for the installation of cogeneration CSP technology in Cyprus

    Directory of Open Access Journals (Sweden)

    Andreas Poullikkas

    2013-12-01

    Full Text Available The purpose of this work is to investigate whether the installation of an innovative cogeneration of electricity and desalinated water (DSW with concentrated solar power (CSP technology in Cyprus is economically feasible. The study takes into account the following generating technologies, (a CSP-DSW technology 4 MWe, (b CSP-DSW technology 10 MWe, (c CSP-DSW technology 25 MWe and (d CSP-DSW technology 50 MWe with or without CO2 trading for two different cases of electricity purchasing tariff. For all above cases the electricity unit cost or benefit before tax, as well as internal rate of return (IRR and payback period (PBP are calculated. The results indicate that the electricity unit cost or benefit for both cases of electricity purchasing tariff are decreased or increased with the increase of the capacity factor and the capacity size of the plant. Also, the additional benefit due to the CO2 ETS price of 10 €/tCO2 for all scenarios is 0.8 €c/kWh. Specifically, for the electricity purchasing tariff of 26 €c/kWh case, the investment in CSP-DSW technology for every capacity size is very attractive, since, the CSP-DSW scenarios have high after tax IRR and low PBP. Despite the lower electricity unit cost benefit in the case of electricity purchasing tariff of 12.83 €c/kWh compared to that of the 26 €c/kWh case, which in some cases there is cost and not benefit, for CSP-DSW plants of 25 MWe and 50 MWe, the investment in this technology is still attractive.

  13. System of lower cogeneration in the cement industry; Sistema de cogeneracion inferior en la industria del cemento

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes, H.; Vazquez, A; Ambriz, J. J.; Fosado, A.; Cedillo, D.; Sanchez, R. [Universidad Autonoma Metropolitana-Iztapalapa (Mexico)

    1999-07-01

    In this paper present work, the design of a cogeneration system was made, taking advantage of the waste thermal flows in a cement manufacturing industry. The costs by concept of energy sources in the cement industry represent between 30 and 60% of the production costs, reason why any diminution in its consumption, will be reflected considerably in the productivity of the company. In order to determine the available capacity of waste energy and to establish the dimension of the cogeneration system it was decided to initially conduct balances of matter and energy of a cement production train. For the evaluation and numerical simulation a case study of a national plant was taken. The analysis takes only into account the rotary kiln, the pre roaster, the gas cooler or conditioner, the cooler of clinker and the separators or dust recuperators. In this study the electrical mills nor the systems that operate all over the plant have been taken in consideration. The results show that in general a high potential of co-generation exists since in some cases the heat losses can reach up to a 50% of the calorific energy input. The capacity of electrical generation by means of a steam turbine when taking advantage of a fraction (in the order of 60%) the residual heat, can be between 200 and 300 watts per kilogram of clinker produced. In conclusion, when recovering by means of appropriate heat exchangers for each one of the mentioned equipment the wasted energy and a network of heat interchange optimized by means of modern technologies an important part of the electrical energy that a cement mill uses can be generated. The method used has been very attractive and with the possibility of applying it to any cement mill and thus evaluate the potentials of energy co-generation. [Spanish] En el presente trabajo, se realizo el diseno de un sistema de cogeneracion aprovechando las corrientes termicas de desecho en una industria de fabricacion de cemento. Los costos por concepto de

  14. Restructuring and regulating district heating and cogeneration in transition economies

    International Nuclear Information System (INIS)

    Brendow, Klaus

    2004-01-01

    In summer 2004, the World Energy Council published a Study on 'Regulating district heating and cogeneration in central and eastern Europe'2, prepared by representatives from eleven economies in transition and two Nordic countries. The Task Force analysed twelve regulatory issues, country-by-country, on all internationally comparable basis. Regulatory progress on the road to more efficient, profitable, competitive and service-oriented heat supplies was described. Common concerns were identified: the need for independence of the regulator from policy and industry, improved coordination between central and local regulators and between environmental and energy authorities, access to grids, and a 'fair' sharing of CHP benefits among heat and electricity generation. Looking forward, the Task Force advocated a continued dialogue between decision makers, regulators, regulated industries and customers on: 1)the internalisation of DH/CHP benefits; 2)the future reduction of the density of regulation; 3) Joint implementation; 4)the compensation for public service obligations; 5)the elimination of old debt and stranded investments; 6) DH/CHP taxation; 7)privatisation; 8)the integration of DH/CHP in urban planning. A concluding WEC workshop in Moscow in March 2004 addressed recommendations to policy makers('Moscow Statement'). (Author)

  15. Co-Generation and Renewables: Solutions for a Low-Carbon Energy Future

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    Co-generation and renewables: solutions for a low-carbon energy future shows that powerful synergies exist when co-generation and renewables work together. The report documents, for the first time, some of the little-known complementary aspects of the two technologies. It also re-emphasises the stand-alone benefits of each technology. Thus, decision makers can use the report as a 'one-stop shop' when they need credible information on co-generation, renewables and the possible synergies between the two. It also provides answers to policy makers' questions about the potential energy and environmental benefits of an increased policy commitment to both co-generation and renewables. Secure, reliable, affordable and clean energy supplies are fundamental to economic and social stability and development. Energy and environmental decision-makers are faced with major challenges that require action now in order to ensure a more sustainable future. More efficient use of, and cleaner primary energy sources can help to achieve this goal. Co-generation -- also known as combined heat and power (CHP) -- represents a proven, cost-effective and energy-efficient solution for delivering electricity and heat. Renewable sources provide clean and secure fuels for producing electricity and heat.

  16. The impact of small scale cogeneration on the gas demand at distribution level

    International Nuclear Information System (INIS)

    Vandewalle, J.; D’haeseleer, W.

    2014-01-01

    Highlights: • Impact on the gas network of a massive implementation of cogeneration. • Distributed energy resources in a smart grid environment. • Optimisation of cogeneration scheduling. - Abstract: Smart grids are often regarded as an important step towards the future energy system. Combined heat and power (CHP) or cogeneration has several advantages in the context of the smart grid, which include the efficient use of primary energy and the reduction of electrical losses through transmission. However, the role of the gas network is often overlooked in this context. Therefore, this work presents an analysis of the impact of a massive implementation of small scale (micro) cogeneration units on the gas demand at distribution level. This work shows that using generic information in the simulations overestimates the impact of CHP. Furthermore, the importance of the thermal storage tank capacity on the impact on the gas demand is shown. Larger storage tanks lead to lower gas demand peaks and hence a lower impact on the gas distribution network. It is also shown that the use of an economically led controller leads to similar results compared to classical heat led control. Finally, it results that a low sell back tariff for electricity increases the impact of cogeneration on the gas demand peak

  17. Feasibility of a medium-size central cogenerated energy facility, energy management memorandum

    Science.gov (United States)

    Porter, R. W.

    1982-09-01

    The thermal-economic feasibility was studied of a medium-size central cogenerated energy facility designed to serve five varied industries. Generation options included one dual-fuel diesel and one gas turbine, both with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired-boiler cases, also low-sulphur coal and municipal refuse. The fired-boiler cogeneration systems employed back-pressure steam turbines. For coal and refuse, the option of steam only without cogeneration was also assessed. The refuse-fired cases utilized modular incinerators. The options provided for a wide range of steam and electrical capacities. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which could be displaced was assumed sold to Commonwealth Edison Company under PURPA (Public Utility Regulator Policies Act). The facility was assumed operated by a mutually owned corporation formed by the cogenerated power users. The economic analysis was predicted on currently applicable energy-investment tax credits and accelerated depreciation for a January 1985 startup date. Based on 100% equity financing, the results indicated that the best alternative was the modular-incinerator cogeneration system.

  18. Optimal design of a cogeneration system for typical hospitals in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Azit, A.H.; Nor, K.M. [Technological Univ. of Malaysia, Kuala Lumpur (Malaysia)

    2008-07-01

    Cogeneration systems produce electricity and heat at decentralized locations. They are efficient energy conversion systems that offer many benefit, including savings in energy consumption. They are very effective compared to centralized bulk generation, particularly if they are located near the load. As such, they are well suited for use in hospitals that have significant thermal loads. However, in order to derive maximum benefits, cogeneration systems must be optimally sized. This paper presented a study of a cogeneration system for a typical hospital buildings in Malaysia. A mixed integer non-linear optimization technique was used to size the system. A Newton Raphson and Conjugate method was used in the optimization process. The optimization technique simulated the cogeneration system along with a thermal storage system. In particular, a cogeneration system for a 5 MW and 2 MW maximum demand hospital facility was simulated using non linear mixed integer optimization programming. Five different capacities of gas turbine generators were used in the simulation to determine the optimal size. The optimization results showed that optimum energy savings and efficiency could be achieved with the right generation output. The optimization used thermal storage to help improve thermal load matching in order to improve the overall efficiency. 7 refs., 3 tabs., 4 figs.

  19. Heat and current coming from the Lengwil TG veneering plant; Chaleur et courant provenant de l'usine de placage de Lengwil TG

    Energy Technology Data Exchange (ETDEWEB)

    Keel, A.

    1998-07-01

    With the recent cogeneration installation of the Lengwil TG veneering plant, the firm Schmid-Holzenergie-Contracting AG showed the possibility to produce current from wood (coupling strength-heat or cogeneration). The implemented installation is described with a special interest in the example of contracting: situations where the operating is different from the energy consumer. In this example the wastes wood of the veneering plant are recovered to feed the energy production system. (A.L.B.)

  20. Public utilities regulatory policy act: Actual versus avoided costs of purchased cogenerated electricity

    International Nuclear Information System (INIS)

    Wilkinson, P.L.; McDowell, B.P.

    1992-01-01

    This chapter examines the actual cost of cogenerated electricity relative to the respective 'avoided costs' as set by the state regulatory commissions, and the cost of other utility purchased power. The chapter is based on 87 cogeneration facilities which have filed for qualifying status under PURPA (QFs). These 87 facilities, located throughout the US, have a combined capacity of nearly 5,700 megawatts - about one-fourth of the total filed with the Federal Energy Regulatory Commission (FERC), and a much higher proportion of the capacity on line today. It should be noted that this chapter focuses on the avoided cost rate as established by the individual state PUCs relative to the rate paid for cogenerated electricity. No attempt was made to determine whether or not the avoided cost rates established accurately reflect the 'true' avoided cost of the individual utilities

  1. Performance assessment of a micro-cogeneration system under realistic operating conditions

    International Nuclear Information System (INIS)

    Rosato, Antonio; Sibilio, Sergio

    2013-01-01

    Highlights: • Performances of a micro-cogeneration system have been experimentally evaluated. • Cogenerator performances have been compared with those of a traditional system. • Measured data have been analyzed from both energy and exergy points of view. - Abstract: The European Parliament stated that high-efficiency cogeneration is a Community priority given the potential benefits of cogeneration with regard to saving primary energy and reducing emissions. According to this position, the performance of many micro-cogeneration systems have been assessed from an energy and environmental point of view. However, in the most part of cases, the assessments have been performed by using technical data from manufacturers and/or experimental results measured during steady-state operation, without considering the inefficiencies related to the transient periods; in addition, few works have been devoted to analyze the system operation from an exergy-based point of view. In this paper the electric load-following operation of an internal combustion engine based micro-cogeneration unit with 6.0 kW as nominal electric output has been experimentally investigated in electric load-following operation during a 24 h dynamic test with the application of a realistic daily load profile representing the Italian domestic non-HVAC electric demand for a multi-family house of five dwellings. The measured data have been compared with those that would be associated with servicing the building with electricity from the central electric grid and heat from a natural gas fired boiler from an energy, exergy and environmental points of view

  2. Achieving emissions reduction through oil sands cogeneration in Alberta’s deregulated electricity market

    International Nuclear Information System (INIS)

    Ouellette, A.; Rowe, A.; Sopinka, A.; Wild, P.

    2014-01-01

    The province of Alberta faces the challenge of balancing its commitment to reduce CO 2 emissions and the growth of its energy-intensive oil sands industry. Currently, these operations rely on the Alberta electricity system and on-site generation to satisfy their steam and electricity requirements. Most of the on-site generation units produce steam and electricity through the process of cogeneration. It is unclear to what extent new and existing operations will continue to develop cogeneration units or rely on electricity from the Alberta grid to meet their energy requirements in the near future. This study explores the potential for reductions in fuel usage and CO 2 emissions by increasing the penetration of oil sands cogeneration in the provincial generation mixture. EnergyPLAN is used to perform scenario analyses on Alberta’s electricity system in 2030 with a focus on transmission conditions to the oil sands region. The results show that up to 15–24% of CO 2 reductions prescribed by the 2008 Alberta Climate Strategy are possible. Furthermore, the policy implications of these scenarios within a deregulated market are discussed. - Highlights: • High levels of cogeneration in the oil sands significantly reduce the total fuel usage and CO 2 emissions for the province. • Beyond a certain threshold, the emissions reduction intensity per MW of cogeneration installed is reduced. • The cost difference between scenarios is not significant. • Policy which gives an advantage to a particular technology goes against the ideology of a deregulated market. • Alberta will need significant improvements to its transmission system in order for oil sands cogeneration to persist

  3. Decentralized cogeneration - A solution for Romania? RAEF experience

    International Nuclear Information System (INIS)

    Binig, Alexandru-Valeriu

    2004-01-01

    deficit should be covered using indigenous power generation sources. One could conclude, correlated with the previous discussion on financing investment, that most of the private capital is expected in the power and heat generation sector. New injection points might necessitate network reinforcement (implying additional costs and delays), may have to pass a complicated and lengthy authorizations process, etc. In conclusion, realisation of 'greenfield' large projects is likely to be cumbersome and delayed due mainly to issues related to connection to the grid. But also fuel supply issues, cooling water access, impact on communities, add to the serious siting problems for new greenfield power generation projects. A psychological impact on private investor's appetite is also given by the continuation of erection of Cernavoda 2, (3?) nuclear units, as these are modern, safe, and optimal at dispatching. In conclusion, in Romania, at present, one cannot identify large private power generation projects in advanced development phase. A solution could be decentralized power generation. Combined with covering a heat demand, it leads to distributed cogeneration. It is an EU and worldwide trend. The above, combined with the overall analysis of the experience in Romania and worldwide allow drawing the following conclusions: - Decentralised generation (cogeneration) is a solution to be considered for Romania and for the region; - The national energy strategy must consider it; - Resources should be allocated to it (not necessarily financial), thus contributing to sustainable development; - It must be promoted by appropriate legislative, regulatory fiscal, etc framework; - Periodic exchange of experience among different actors is decisive for avoiding wasting resources; - this is mainly the purpose of the present article; - Private initiative is the main driver and must be encouraged for promoting efficiency and sustainability; - The solution chosen yields better risk management while

  4. European energy policy and the potential impact of HTR and nuclear cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    Fütterer, Michael A., E-mail: michael.fuetterer@ec.europa.eu [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755ZG Petten (Netherlands); Carlsson, Johan [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755ZG Petten (Netherlands); Groot, Sander de [Nuclear Research and consultancy Group, NL-1755ZG Petten (Netherlands); Deffrennes, Marc [European Commission, DG ENER, L-2530 Luxembourg (Luxembourg); Bredimas, Alexandre [LGI Consulting, 13 rue Marivaux, F-75002 Paris (France)

    2014-05-01

    This paper first provides an update on the current state of play and the potential future role of nuclear energy in Europe. It then describes the EU energy policy tools in the area of nuclear technology. It explains the three-tier strategy of the European nuclear technology platform and its demonstration initiatives, here specifically for nuclear cogeneration and HTR. The paper closes with an outlook on the boundary conditions at which HTR can become attractive for nuclear cogeneration, not only from an energy policy viewpoint but also economically.

  5. European energy policy and the potential impact of HTR and nuclear cogeneration

    International Nuclear Information System (INIS)

    Fütterer, Michael A.; Carlsson, Johan; Groot, Sander de; Deffrennes, Marc; Bredimas, Alexandre

    2014-01-01

    This paper first provides an update on the current state of play and the potential future role of nuclear energy in Europe. It then describes the EU energy policy tools in the area of nuclear technology. It explains the three-tier strategy of the European nuclear technology platform and its demonstration initiatives, here specifically for nuclear cogeneration and HTR. The paper closes with an outlook on the boundary conditions at which HTR can become attractive for nuclear cogeneration, not only from an energy policy viewpoint but also economically

  6. Cogeneration through small and medium sized gas turbines in Italy: Marketing survey

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, A.; Schieppati, P.

    1992-12-01

    In Italy, the use of cogeneration systems by private industrial concerns has greatly increased in the early 90's. The successful technological development of highly efficient low and medium sized gas turbines and the successful application of cogenerated power to a number of industrial processes, favourable legislation and financial incentives on the part of the Italian Government, especially interested in promoting energy conservation and the use of natural gas as an alternative to petroleum, as well as, fast payback periods for such investments are amongst the major regions for the growing demand for this type of power system alternative in Italy.

  7. What is the future for gas cogeneration in the French context?

    International Nuclear Information System (INIS)

    Ades, D.

    1996-01-01

    The first part of this work is devoted to the institutional environment which hold the cogeneration success in France. Cogeneration is indeed a future technology but is under-exploited in France. The future communal lines and the conclusions of the study group, suggested to the Cabinet of the European Union in 1995, should meanwhile cope with some difficulties for its development in France. The second part deals more particularly with the customers listening and with their expectations towards the energy suppliers. (O.M.)

  8. Thermal Efficiency of Cogeneration Units with Multi-Stage Reheating for Russian Municipal Heating Systems

    Directory of Open Access Journals (Sweden)

    Evgeny Lisin

    2016-04-01

    Full Text Available This paper explores the layout of an optimum process for supplying heat to Russian municipal heating systems operating in a market environment. We analyze and compare the standard cogeneration unit design with two-stage reheating of service water coming from controlled extraction locations and layouts that employ three in-line reheaters with heat the supply controlled by a rotary diaphragm and qualitative/quantitative methods (so-called “uncontrolled extraction”. Cogeneration unit designs are benchmarked in terms of their thermal efficiency expressed as a fuel consumption rate. The specific fuel consumption rate on electricity production is viewed as a key parameter of thermal efficiency.

  9. Thermionic cogeneration burner assessment study. Third quarterly technical progress report, April-June, 1983

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    The specific tasks of this study are to mathematically model the thermionic cogeneration burner, experimentally confirm the projected energy flows in a thermal mock-up, make a cost estimate of the burner, including manufacturing, installation and maintenance, review industries in general and determine what groups of industries would be able to use the electrical power generated in the process, select one or more industries out of those for an in-depth study, including determination of the performance required for a thermionic cogeneration system to be competitive in that industry. Progress is reported. (WHK)

  10. Development of residential PEFC cogeneration systems at Osaka Gas

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Osamu; Echigo, Mitsuaki; Shinke, Norihisa; Tabata, Takeshi [Osaka Gas Ltd., Kyoto (Japan)

    2001-07-01

    The outline of residential PEFC cogeneration system development at Osaka Gas is described in this presentation. The developments of CO preferential oxidation catalyst, fuel processor, and the evaluation study of MEA are explained in detail. Osaka Gas has developed CO preferential oxidation catalyst, which can reduce the concentration of CO in the reformed gas below 1 ppm at the O{sub 2}/CO of 1.5. The durability of the catalyst for more than 10,000 hours has also been confirmed. A fuel processor in which desulfurization, steam reforming, CO shift conversion and CO removal reactors are integrated has also been developed. Catalysts, the durability of which have been verified for more than 50,000 hours, were employed in the reactors for desulfurization, steam reforming and CO shift conversion, and newly developed catalyst mentioned above was employed for the CO preferential oxidation reactor. The initial performance of the fuel processor has been established. The thermal efficiency of 77% has been accomplished under the condition of S/C: 2.5, O{sub 2}/CO: 1.5 and the utilization rate of fuel at the cell stack (Uf): 80%. And further, the durability for more than 1000 hours was confirmed. Durability of MEAs manufactured by Japan Gore-Tex and 3M have been evaluated. Small degradation rate of ca. 2 mV 11,000 h was found at the current density of 300 mAcm{sup -2}, Uf of 60% and the temperature of 70 {sup o}C. The tolerance of anode for CO has also been investigated, and had confirmed that the decline of cell performance could be negligible when the concentration of CO was less than 10 ppm. (author)

  11. Development of a Novel Efficient Solid-Oxide Hybrid for Co-generation of Hydrogen and Electricity Using Nearby Resources for Local Application

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Greg, G.; Virkar, Anil, V.; Bandopadhyay, Sukumar; Thangamani, Nithyanantham; Anderson, Harlan, U.; Brow, Richard, K.

    2009-06-30

    Developing safe, reliable, cost-effective, and efficient hydrogen-electricity co-generation systems is an important step in the quest for national energy security and minimized reliance on foreign oil. This project aimed to, through materials research, develop a cost-effective advanced technology cogenerating hydrogen and electricity directly from distributed natural gas and/or coal-derived fuels. This advanced technology was built upon a novel hybrid module composed of solid-oxide fuel-assisted electrolysis cells (SOFECs) and solid-oxide fuel cells (SOFCs), both of which were in planar, anode-supported designs. A SOFEC is an electrochemical device, in which an oxidizable fuel and steam are fed to the anode and cathode, respectively. Steam on the cathode is split into oxygen ions that are transported through an oxygen ion-conducting electrolyte (i.e. YSZ) to oxidize the anode fuel. The dissociated hydrogen and residual steam are exhausted from the SOFEC cathode and then separated by condensation of the steam to produce pure hydrogen. The rationale was that in such an approach fuel provides a chemical potential replacing the external power conventionally used to drive electrolysis cells (i.e. solid oxide electrolysis cells). A SOFC is similar to the SOFEC by replacing cathode steam with air for power generation. To fulfill the cogeneration objective, a hybrid module comprising reversible SOFEC stacks and SOFC stacks was designed that planar SOFECs and SOFCs were manifolded in such a way that the anodes of both the SOFCs and the SOFECs were fed the same fuel, (i.e. natural gas or coal-derived fuel). Hydrogen was produced by SOFECs and electricity was generated by SOFCs within the same hybrid system. A stand-alone 5 kW system comprising three SOFEC-SOFC hybrid modules and three dedicated SOFC stacks, balance-of-plant components (including a tailgas-fired steam generator and tailgas-fired process heaters), and electronic controls was designed, though an overall

  12. An investigation of the techno-economic impact of internal combustion engine based cogeneration systems on the energy requirements and greenhouse gas emissions of the Canadian housing stock

    International Nuclear Information System (INIS)

    Asaee, S. Rasoul; Ugursal, V. Ismet; Beausoleil-Morrison, Ian

    2015-01-01

    This study provides a techno-economic evaluation of retrofitting internal combustion engine (ICE) based cogeneration systems in the Canadian housing stock (CHS). The study was conducted using the Canadian Hybrid Residential End-Use Energy and GHG Emissions Model (CHREM). CHREM includes close to 17,000 unique house files that are statistically representative of the Canadian housing stock. The cogeneration system performance was evaluated using a high resolution integrated building performance simulation software. It is assumed that the ICE cogeneration system is retrofitted into all houses that currently use a central space heating system and have a suitable basement or crawl space. The GHG emission intensity factor associated with marginal electricity generation in each province is used to estimate the annual GHG emissions reduction due to the cogeneration system retrofit. The results show that cogeneration retrofit yields 13% energy savings in the CHS. While the annual GHG emissions would increase in some provinces due to cogeneration retrofits, the total GHG emissions of the CHS would be reduced by 35%. The economic analysis indicates that ICE cogeneration system retrofits may provide an economically feasible opportunity to approach net/nearly zero energy status for existing Canadian houses. - Highlights: • Techno-economic evaluation ICE cogeneration systems for Canadian housing is reported. • ICE cogeneration retrofit could yield 13% annual energy savings in Canadian housing. • Annual GHG emissions of Canadian housing could decrease by 35% with ICE cogeneration. • But, in some provinces, GHG emissions would increase as a result of ICE cogeneration

  13. Feasibility analysis of installing a natural gas cogeneration system in a slaughterhouse; Analise da viabilidade da implantacao de um sistema de cogeracao de energia a gas natural em um frigorifico

    Energy Technology Data Exchange (ETDEWEB)

    Takaki, Alessandro Tomio; Dib, Fernando Henrique; Campitelli, Flavio Moreti; Romao Junior, Ricardo Agudo; Ramos, Ricardo Alan Verdu [Universidade Estadual Paulista (NUPLEN/UNESP), Ilha Solteira, SP (Brazil). Dept. de Engenharia Mecanica. Nucleo de Planejamento Energetico, Geracao e Cogeracao de Energia], Email: nuplen@dem.feis.unesp.br

    2006-07-01

    In this work the analysis of the viability of implantation of a natural gas cogeneration system in a bovine slaughterhouse is carried out. Among the studied configurations there are the current plant and the modified plant that allow the use of natural gas. For evaluation of the performance, energetic and exegetic analyses for each one of the configurations are carried out. It's also accomplished a thermo economic analysis that makes possible to evaluate the reflexes of the investment and combustible on the composition of the cost of products. (author)

  14. An object-oriented computational model for combined cycle cogeneration analysis; Um modelo computacional para analise de ciclos combinados para projetos de sistemas de cogeracao

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alexandre M. da; Balestieri, Jose A.P.; Magalhaes Filho, Paulo [UNESP, Guaratingueta, SP (Brazil). Escola de Engenharia. Dept. de Energia]. E-mails: amarcial@uol.com.br; perella@feg.unesp.br; pfilho@feg.unesp.br

    2000-07-01

    This paper presents the use of computational resources in a simulation procedure to predict the performance of combined cycle cogeneration systems in which energetic analysis is used in the modeling. Thermal demand of a consuming process are used as the main entrance data and, associated to the performance characteristics of each component of the system, it is evaluated the influence of some parameters of the system such as thermal efficiency and global efficiency. The computational language is Visual Basic for Applications associated to an electronic sheet. Two combined cycle cogeneration schemes are pre-defined: one is composed of a gas turbine, heat recovery steam generator and a back pressure steam turbine with one extraction, in which both are connected to the different pressure level process plant; the other scheme has a difference a two extraction-condensing steam turbine instead of the back pressure one. Some illustrative graphics are generated for allowing comparison of the appraised systems. The strategy of the system simulation is obtained by carefully linking the information of various components according to the flow diagrams. (author)

  15. Evaluation of avoided carbon dioxide emissions in cogeneration projects; Evaluacion de las emisiones evitadas de bioxido de carbono en proyectos de cogeneracion

    Energy Technology Data Exchange (ETDEWEB)

    Flores Zamudio, Jesus Antonio; Fernandez Montiel, Manuel Francisco; Alcaraz Calderon, Agustin Moises [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: jesus.flores@iie.org.mx; mffm@iie.org.mx; malcaraz@iie.org.mx

    2010-11-15

    In this paper, presents a methodology of how to calculate the emissions of CO{sub 2} (Carbon Dioxide) in cogeneration of plants for evaluate future cases with the type of fuel and fuel flow used in the plant. The methodology was in spreadsheets developed a series of stoichiometric balances. The methodology was done for three types of fossil fuels: solid, liquid and gas. The analysis is made only to the percentages of the items contained in the fuel flow automatically used and results in the combustion products in tons per hour. This method was compared with the results obtained in the software Thermoflow Inc. (Used in Gerencia de Procesos Termicos of Instituto de Investigaciones Electricas for evaluate various process systems that produce energy power) using different cogeneration systems, that is to say about the technology used emissions compared according to the amount of excess air for each type of technology and at one point before the gas cleaning systems. The results can be evaluated for emissions avoided through the fuel type used and developing a cogeneration plant compared to a conventional plant. [Spanish] En este articulo, se presenta una metodologia de como calcular las emisiones de CO{sub 2} (Bioxido de carbono) en plantas de cogeneracion, para evaluar casos a futuro por medio del tipo de combustible y flujo de combustible a utilizar en la planta. La metodologia se realizo en hojas de calculo, donde se desarrollaron una serie de balances estequiometricos. La metodologia se hizo para tres tipos de combustibles fosiles: solido, liquido y gas. El analisis se realiza con solo dar los porcentajes de los elementos que contiene el combustible y el flujo a utilizarse y automaticamente da como resultado los productos de la combustion en toneladas por hora. Esta metodologia se comparo con los resultados obtenidos en el software Thermoflow Inc. (Empleado en la Gerencia de Procesos Termicos del Instituto de Investigaciones Electricas para evaluar diversos

  16. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and

  17. Cogeneration : A Regulatory Guide to Leasing, Permitting, and Licensing in Idaho, Montana, Oregon, and Washington.

    Energy Technology Data Exchange (ETDEWEB)

    Deshaye, Joyce; Bloomquist, R. Gordon

    1992-12-01

    This guidebook focuses on cogeneration development. It is one of a series of four guidebooks recently prepared to introduce the energy developer to the federal, state and local agencies that regulate energy facilities in Idaho, Montana, Oregon, and Washington (the Bonneville Power Administration Service Territory). It was prepared specifically to help cogeneration developers obtain the permits, licenses and approvals necessary to construct and operate a cogeneration facility. The regulations, agencies and policies described herein are subject to change. Changes are likely to occur whenever energy or a project becomes a political issue, a state legislature meets, a preexisting popular or valuable land use is thought threatened, elected and appointed officials change, and new directions are imposed on states and local governments by the federal government. Accordingly, cogeneration developers should verify and continuously monitor the status of laws and rules that might affect their plans. Developers are cautioned that the regulations described herein may only be a starting point on the road to obtaining all the necessary permits.

  18. Assessing the economic feasibility of flexible integrated gasification Co-generation facilities

    NARCIS (Netherlands)

    Meerman, J.C.; Ramírez Ramírez, C.A.; Turkenburg, W.C.; Faaij, A.P.C.

    2011-01-01

    This paper evaluated the economic effects of introducing flexibility to state-of-the-art integrated gasification co-generation (IGCG) facilities equipped with CO2 capture. In a previous paper the technical and energetic performances of these flexible IG-CG facilities were evaluated. This paper

  19. Reviews on Fuel Cell Technology for Valuable Chemicals and Energy Co-Generation

    Directory of Open Access Journals (Sweden)

    Wisitsree Wiyaratn

    2010-07-01

    Full Text Available This paper provides a review of co-generation process in fuel cell type reactor to produce valuable chemical compounds along with electricity. The chemicals and energy co-generation processes have been shown to be a promising alternative to conventional reactors and conventional fuel cells with pure water as a byproduct. This paper reviews researches on chemicals and energy co-generation technologies of three types of promising fuel cell i.e. solid oxide fuel cell (SOFC, alkaline fuel cell (AFC, and proton exchange membrane fuel cell (PEMFC. In addition, the research studies on applications of SOFCs, AFCs, and PEMFCs with chemical production (i.e. nitric oxide, formaldehyde, sulfur oxide, C2 hydrocarbons, alcohols, syngas and hydrogen peroxide were also given. Although, it appears that chemicals and energy co-generation processes have potential to succeed in commercial applications, the development of cheaper catalyst materials with longer stability ,and understanding in thermodynamic are still challenging to improve the overall system performance and enable to use in commercial market.

  20. Assesment of Emerging Renewable Energy-based Cogeneration Systems for nZEB Residential Buildings

    DEFF Research Database (Denmark)

    Carmo, Carolina; Dumont, Olivier; Nielsen, Mads Pagh

    2016-01-01

    Net Zero Energy Buildings (nZEB) imply reduced consumption by means of good insulation, passive strategies and highly efficient energy supply systems. Among others, micro cogeneration systems are considered as one of the system solutions with the highest potential to enable nZEB. These systems en...

  1. Life cycle inventory of electricity cogeneration from bagasse in the South African sugar industry

    CSIR Research Space (South Africa)

    Mashoko, L

    2013-01-01

    Full Text Available methodology. This study develops the life cycle inventories for bagasse power production in South Africa. The life cycle inventory can help to evaluate the environmental impacts of the cogeneration throughout the life cycle. The data for this inventory stage...

  2. Improvement of the cogeneration facilities, considering the aspects of financial risks

    International Nuclear Information System (INIS)

    Santos, A.H.M.; Nogueira, L.A.H.; Costa Bortoni, E. da

    1992-01-01

    This paper proposes a methodology to include the tools of the Portfolio Theory in the design of the cogeneration facilities. So, the effects of the risk on the return can be take in account. A computer program was developed to simulate the impacts of the thermal and mechanical (or electrical) loads on energy surplus and the potential risk. (C.M.)

  3. Assessment of Emerging Renewable Energy-based Cogeneration Systemsfor nZEB Residential Buildings

    DEFF Research Database (Denmark)

    Carmo, Carolina; Dumont, Olivier; Nielsen, Mads P.

    2016-01-01

    thermal reversible heat pump /organic Rankine cycle (HP/ORC) and cogeneration solar Thermoelectric generators (TEG).This paper aims to give an overview of the state-of-the-art developments, discuss the fundamental and technical challenges facing commercial adoption and prospects of these technologies...

  4. Experiment on the use of a new source of renewable primary energy in Romania for rendering more efficient cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    Gheorghiu, Ioan Dan; Dragos, Gligor; Carabulea, A.; Popper, Laurentiu; Ungureanu, Ion

    2007-07-01

    The fuel renewing in the coal-running power plants, has been ordered by the competitive market mandatory prices of energy. The compliance with this restriction claims the decrease of fuels share to the energy cost from 75% to 35% by using a new type of fuel (corn) with a heat value ober 4,000 Kcal/Kg, compared with that of the coal, 1700 Kcal/Kg. This renewal applied to Romania, Oradea power plant has resulted in the following performances: reducing to half of the co-generation power costs, the thermal power produced from energy savings can heat, annually, 2.10{sup 6} apartments, the reconfiguration of human resource by the conversion of miners to corn-cultivating farmers, completely environment pollution diminishing the ash resulted from corn combustion, is a performing fertilizer for the cultivated corn. The technical-economic parameters, applied in this particular case to the experiment, show that the capital formation rate increases to 1.5 lei revenue/1 invested leu and the probable resources can be recovered, easily, from the annual resulted profits. (auth)

  5. Cogeneration and District Heating. Best Practices for Municipalities

    International Nuclear Information System (INIS)

    Nuorkivi, A.; Constantinescu, T.

    2005-01-01

    District heating (DH) and cogeneration of heat power (CHP) are well known technologies in the energy business and are often included in municipal policies as well. Some of the major benefits of DH and CHP are less known and the barriers faced by further development of DH and CHP are substantial. The main barriers are institutional. Municipalities can play a powerful role in facilitating local DH and CHP development in order to achieve the economic and environmental benefits of DH and CHP. This report is produced to assist municipalities in promoting efficient and environmental beneficial DH and CHP. The focus of the report is on the economies in transition, where the institutional barriers are acute. The report addresses the issues of organisational framework, price regulation and financing, energy demand, rehabilitation of DH systems and benchmarking of DH and CHP. The municipality may influence the DH development by a number of means. The most important means, discussed in the various chapters of the report, are: (1) City planning impacts on the heat load density. A high density is an important factor for the economics of DH and city planning may promote DH in areas with high density and individual heating modes in the areas with low density; (2) Managing the building stock owned by the municipality to join the DH system and paying for the heating services; (3) Setting strategic goals for the District Heating Enterprise (DHE), which they usually own, regarding the quality and the costs of heating. The DHE shall be given sufficient resources to work towards such goals; (4) Providing guarantees for financing DH rehabilitation and development. The DHE may not have access to commercial credits without municipal guarantees; and, (5) Supporting the DHE management by giving operational independence, supervising the management performance regularly and encouraging the co-operation with other DHEs and equipment manufacturers. Examples provided in the report of

  6. Tetra-combined cogeneration system. Exergy and thermo economic evaluation; Sistema tetra combinado de cogeracao. Avaliacao exergetica e termoeconomica

    Energy Technology Data Exchange (ETDEWEB)

    Arriola, Domingo Wilson Garagatti [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: wgarriol@usp.br; Oliveira Junior, Silvio de [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil)]. E-mail: olivsilj@ipt.br

    2000-07-01

    This paper presents the description and the exergy and thermo economic evaluation of a new cogeneration system, called tetra-combined cogeneration system, that generates electricity and chilled water (for air conditioning purposes) and eventually steam. This system is composed of a gas turbine, a heat recovery steam generator, a condensation/extraction steam turbine and a hybrid absorption/steam ejection chiller. The exergy and thermo economic performance (exergy based costs of electricity, steam and chilled water production) of this system is compared with the performances of conventional cogeneration systems, pointing out the advantages and disadvantages of this new system. (author)

  7. Tetra-combined cogeneration system. Exergy and thermoeconomic evaluation; Sistema tetra combinado de cogeracao. Avaliacao exergetica e termoeconomica

    Energy Technology Data Exchange (ETDEWEB)

    Arriola, Domingo Wilson Garagatti [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: wgarriol@usp.br; Oliveira Junior, Silvio de [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil)]. E-mail: olivsilj@ipt.br

    2000-07-01

    The description and the exergy and thermo economic evaluation of a new cogeneration system, called tetra-combined cogeneration system, that generates electricity and chilled water (for air conditioning purposes) and eventually steam is presented. This system is composed of a gas turbine, a heat recovery steam generator, a condensation/extraction steam turbine and a hybrid absorption/steam ejection chiller.The exergy and thermo economic performance (exergy based costs of electricity, steam and chilled water production) of this system is compared with the performances of conventional cogeneration systems, pointing out the advantages and disadvantages of this new system. (author)

  8. Techno-economic assessment and optimization of Stirling engine micro-cogeneration systems in residential buildings

    International Nuclear Information System (INIS)

    Alanne, Kari; Soederholm, Niklas; Siren, Kai; Beausoleil-Morrison, Ian

    2010-01-01

    Micro-cogeneration offers numerous potential advantages for the supply of energy to residential buildings in the sense of improved energy efficiency and reduced environmental burdens. To realize these benefits, however, such systems must reduce energy costs, primary energy consumption, and CO 2 emissions relative to conventional heating systems. In this paper, we search for optimized strategies for the integration of a Stirling engine-based micro-cogeneration system in residential buildings by comparing the performance of various system configurations and operational strategies with that of a reference system, i.e. hydronic heating and a low temperature gas boiler in standard and passive house constructions located in different climates. The IDA-ICE whole-building simulation program is employed with the Stirling engine micro-cogeneration model that was developed by IEA/ECBCS Annex 42. In this way the dynamic effects of micro-cogeneration devices, such as warm-ups and shutdowns, are accounted for. This study contributes to the research by addressing hourly changes in the fuel mix used for central electricity generation and the utilization of thermal exhaust through heat recovery. Our results suggest that an optimally operated micro-cogeneration system encompassing heat recovery and appropriate thermal storage would result in a 3-5% decrease in primary energy consumption and CO 2 emissions when compared to a conventional hydronic heating system. Moreover, this configuration is capable of delivering annual savings in all the combinations of electricity and fuel price between 0.05 and 0.15 Euro kW h -1 . As can be expected, these results are sensitive to the electrical energy supply mix, building type, and climate.

  9. Mini-cogeneration in the flower bulb industry. Use of cogeneration in the cultivation and hot bed of tulip and hyacinth; Mini-wkk in de bloembollensector. Toepassing van wkk bij teelt en broei van tulp en hyacint

    Energy Technology Data Exchange (ETDEWEB)

    De Visser, I.; Koolwijk, E. [Cogen Projects, Driebergen-Rijsenburg (Netherlands)

    2008-06-15

    This study shows that by deploying cogeneration, energy savings can be realized in the flower bulb industry. Use of cogeneration at medium-sized to large flower bulb companies is interesting from the viewpoint of finance. [Dutch] Uit de studie blijkt dat met de toepassing van WKK energiebesparing gerealiseerd kan worden in de bollensector. Op de middelgrote tot grote bollenbedrijven is de toepassing van WKK uit financieel oogpunt interessant.

  10. Rational use of energy and cogeneration in Argentina; Uso racional de la energia y la cogeneracion en Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Sosa, M.I. [Universidad Nacional de La Plata (GECCU/UNLP), Buenos Aires (Argentina). Fac. de Ingenieria. Sistemas de Generacion de Energia, Cogeneracion, Ciclos Combinados, Uso Racional de la Energia], E-mail: misosa@ing.unlp.edu.ar

    2009-07-01

    In this paper we discuss the energy situation in Argentina and indicates possibilities for the implementation of cogeneration projects in the industrial sector, which would include energy generated by a centralized system, without additional consumption of primary resources. We discuss the physical potential of cogeneration and regulatory barriers that do not assist in its implementation. Mentioned government measures on rational and efficient use of energy.

  11. Guideline for implementing Co-generation based on biomass waste from Thai industries

    Energy Technology Data Exchange (ETDEWEB)

    Lybaek, R.

    2005-07-01

    Due to the large-scale industrial development in Thailand the consumption of energy - primarily based on fossil fuels - has increased enormously, even though the economic growth has slowed down since the economic crisis in 1997. It is, therefore, important to reduce the environmental impact of this energy consumption, which can be achieved by energy conservation, higher efficiency in the production of energy, or by the use of different kinds of renewable energy. This thesis seeks to develop new strategies for the use of waste heat as a part of the industrial process heat, which can be supplied to industries by a district-heating network. By substituting process heat - produced by electricity or by boilers using fossil fuel in individual industries - with process heat, produced by a co-generation plant - using the industries own biomass waste as fuel - process heat can be supplied to industries participating in a small scale district heating network. Thus, an Industrial Materials Network can be created, which is environmentally as well as economically beneficial for both industry and society. On the basis of a case study of the industrial area, Navanakorn Industrial Promotion Zone in Thailand, such initiatives for efficient materials and energy uses have been conducted and proved successful, and industries - as well as local and national governmental agencies, NGOs and branch organizations etc. - have shown interest in supporting the implementation of such scheme. In this thesis, a Guideline for large-scale implementation of Industrial Materials Network in Thailand was developed. By following a series of actions, the Guideline defines the initiatives that must be taken in order to ensure correct implementation. Chronologically, the emphasis of the Guideline is on pointing to relevant stakeholders who can pursue the implementation, and then appropriate areas and types of industries for Industrial Materials Network implementation. Thereafter, guidance for the

  12. Study of technical and economic feasibility of a cogeneration system in the tertiary sector; Estudo de viabilidade tecnica-economica de um sistema de cogeracao no setor terciario

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Rodolffo Aquino de; Rocha, Carlos Roberto; Bortoni, Edson da Costa [Universidade Federal de Itajuba (EXCEN/UNIFEI), MG (Brazil). Centro de Excelencia em Eficiencia Energetica

    2008-07-01

    This study aims to examine the technical feasibility and financial cost for a cogeneration system in a company in the tertiary sector. For this, was studied the electromechanical and thermal characteristics of a shopping center, as well as the technologies associated with the proposed cogeneration system. From the modeling of electric and thermal loads it was determined the system of operation for the system and the possible surplus energy generated. For the analysis of economic viability compare operating costs without cogeneration and with the alternative of cogeneration chosen. Among the calculations are the costs of investment and operation of the system. Was encountered the attractiveness of a cogeneration system, which uses natural gas as fuel for alternative engines and, in turn, reject heat to the absorption chillers. The idealized cogeneration system was also evaluated positively with a view to qualification required for participation in policies to encourage the rational use of energy resources. (author)

  13. Design of the measurements validation procedure and the expert system architecture for a cogeneration internal combustion engine

    International Nuclear Information System (INIS)

    Barelli, L.; Bidini, G.

    2005-01-01

    A research activity has been initiated to study the development of a diagnostic methodology, for the optimization of energy efficiency and the maximization of the operational time in those conditions, based on artificial intelligence (AI) techniques such as artificial neural network (ANN) and fuzzy logic. The diagnostic procedure, developed specifically for the cogeneration plant located at the Engineering Department of the University of Perugia, must be characterized by a modular architecture to obtain a flexible architecture applicable to different systems. The first part of the study deals with the identifying the principal modules and the corresponding variables necessary to evaluate the module 'health state'. Also the consequent upgrade of the monitoring system is described in this paper. Moreover it describes the structure proposed for the diagnostic procedure, consisting of a procedure for measurement validation and a fuzzy logic-based inference system. The first reveals the presence of abnormal conditions and localizes their source distinguishing between system failure and instrumentation malfunctions. The second provides an evaluation of module health state and the classification of the failures which have possibly occurred. The procedure was implemented in C++

  14. Cogeneration Technology Alternatives Study (CTAS). Volume 6: Computer data. Part 1: Coal-fired nocogeneration process boiler, section A

    Science.gov (United States)

    Knightly, W. F.

    1980-01-01

    Various advanced energy conversion systems (ECS) are compared with each other and with current technology systems for their savings in fuel energy, costs, and emissions in individual plants and on a national level. About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidates which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on-site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented for coal fired process boilers. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented.

  15. Use of biogas for cogeneration of heat and electricity for local application: performance evaluation of an engine power generator and a sludge thermal dryer.

    Science.gov (United States)

    Lobato, L C S; Chernicharo, C A L; Pujatti, F J P; Martins, O M; Melo, G C B; Recio, A A R

    2013-01-01

    A small unit of cogeneration of energy and heat was tested at the Centre for Research and Training on Sanitation UFMG/COPASA - CePTS, located at the Arrudas Sewage Treatment Plant, in Belo Horizonte, Minas Gerais, Brazil. The unit consisted of an engine power generator adapted to run on biogas, a thermal dryer prototype and other peripherals (compressor, biogas storage tank, air blower, etc.). The heat from engine power generator exhaust gases was directed towards the thermal dryer prototype to dry the sludge and disinfect it. The results showed that the experimental apparatus is self-sufficient in electricity, even producing a surplus, available for other uses. The tests of drying and disinfection of sludge lasted 7 h, leading to an increase in solids content from 4 to 8% (50% reduction in sludge volume). Although the drying of sludge was not possible (only thickening was achieved), the disinfection process proved very effective, enabling the complete inactivation of helminth eggs.

  16. Cogeneration from Poultry Industry Wastes -- Part II: Economic Analysis

    DEFF Research Database (Denmark)

    Bianchi, M.; Cherubini, F.; Pascale, A. D.

    2003-01-01

    The availability of wet biomass as waste from a lot of industrial processes, from agriculture and farms and the need to meet the environmental standards force to investigate all options in order to dispose this waste. The possible treatments usually strongly depend on the biomass characteristics......, namely water content, density, organic content, heating value, etc. In particular some of these wastes can be burnt in special plants, using them as energy supply for different processes. The study carried out with this paper is concerned with the promising tilization of the organic wastes from...... an existing poultry industry as fuel. Different plant configurations have been considered in order to make use of the oil and of the meat and bone meal, which are the by-products of the chicken cooking process. In particular, the process plant can be integrated with an energy supply plant which can consist...

  17. Cogeneration projects in PEMEX refining; Proyectos de cogeneracion en PEMEX Refinacion

    Energy Technology Data Exchange (ETDEWEB)

    Becerra O' Leary, Jose [Petroleos Mexicanos (Mexico)

    2006-10-15

    Mexican Petroleum proposes the electric power cogeneration, the energy consumption and rationalization as well as the operative performance improvement. This is the reason Pemex refining considers the cogeneration projects development possibility related with the Refining National System to supply the six refineries with steam and electric power. And also the energy auto-supply to other Pemex refining, using the liquid and solid residuals as fuels for petroleum refining. [Spanish] Petroleos Mexicanos propone la Cogeneracion de energia electrica, el aprovechamiento y la racionalizacion del consumo de energia, asi como el mejoramiento del desempeno operativo, por lo cual Pemex Refinacion plantea la posibilidad del desarrollo de proyectos de Cogeneracion asociados a las refinerias del Sistema Nacional de Refinacion, para abastecer de vapor y energia electrica a cada una de las seis refinerias, asi como el autoabastecimiento de energia a otras instalaciones de Pemex Refinacion, utilizando como combustibles los residuales liquidos y solidos de la refinacion del petroleo.

  18. High-efficiency Gas Cogeneration – an Assessment of the Support Mechanism

    Directory of Open Access Journals (Sweden)

    Maciej Sołtysik

    2015-09-01

    Full Text Available The development of a single European energy market implies the need to harmonise national laws and the directions of the sector’s growth to EU determinants. One of these elements was the introduction of a system to support the development of high-efficiency cogeneration, including gas cogeneration. Several years of the mechanisms’ performance allows for analysis of the advisability and correctness of the support model format, and assessment of its impact on the sub-sector’s development and the cost of its operation. Against the background of the support system introduction origins, the paper presents results of volumetric and price analyses, trends, and assessment of the balance of property rights and of the mechanism’s effectiveness.

  19. Cogeneration of heat and power in Crete - Greece from olive tree byproducts and residues

    Energy Technology Data Exchange (ETDEWEB)

    Vourdoubas, J. (TEI of Crete, Chania (Greece), Dept. of Natural Resources and Environment), e-mail: gboyrd@tee.gr

    2010-07-01

    Olive tree byproducts and residues are used mainly in Crete for heat production, but not for power generation. The most of Olive Kernel wood is currently used for heat generation without any standardization, but the most of olive tree brushes are not used for energy production. Therefore, a lot of solid biomass in Crete, which is not used at the moment, can be exploited in the future for generation of heat and power or for cogeneration of them. Olive tree byproducts and residues can be used with burning, but, because of the mild climate of the island, the cogenerated heat can be efficiently used only during the winter. Also, the possibility of tri-generation exists since the produced heat can be used for cooling generation with absorption chillers. The availability of Olive Kernel wood in Crete is estimated at the moment at 110,000 tn / year and of Olive tree brushes at 380,000 tn / year. (orig.)

  20. Greenhouse gas emission for co-generation installation - reduction and selling

    International Nuclear Information System (INIS)

    Manev, S.; Stankov, N.; Asenov, A.

    2005-01-01

    According to Kyoto protocol countries which have the availability to buy green house gas emissions from other countries could be made by means of realization of investment project. In this article the authors review the necessary scope of work which have to be done in order particular project for co-generation installation to be realized, according the requirement and their own experience in this field

  1. Solar Cogeneration of Electricity and Hot Water at DoD Installations

    Science.gov (United States)

    2014-06-01

    be designed to provide a minimum of 30% of the facility’s hot water demand by solar water heating. Waste heat harvesting , integrated co-generation...water demand by solar water heating. Waste heat harvesting , integrated co-generation systems, or a combination thereof may be used in lieu of solar...field operations team are summarized below for the demonstration installations. Port Hueneme • Early morning fog and cloud cover at Port Hueneme

  2. Thermodynamic Investigation of a Shared Cogeneration System with Electrical Cars for Northern Europe Climate

    OpenAIRE

    Vialetto, Giulio; Noro, Marco; Rokni, Masoud

    2017-01-01

    Transition to alternative energy systems is indicated by EU Commission as a suitable path to energy efficiency and energy saving in the next years. The aims are to decrease greenhouses gases emissions, relevance of fossil fuels in energy production and energy dependence on extra-EU countries. These goals can be achieved increasing renewable energy sources and/or efficiency on energy production processes. In this paper an innovative micro-cogeneration system for household application is presen...

  3. Experimental study on a resorption system for power and refrigeration cogeneration

    International Nuclear Information System (INIS)

    Jiang, L.; Wang, L.W.; Liu, C.Z.; Wang, R.Z.

    2016-01-01

    Energy conversion technologies, especially for power generation and refrigeration technologies driven by the low temperature heat, are gathering the momentum recently. This paper presents a novel resorption system for electricity and refrigeration cogeneraion. Compared with adsorption refrigeration system, resorption refrigeration is characterized as safety and simple structure since there is no ammonia liquid in the system. The cogeneration system is mainly composed of three HTS (high temperature salt) unit beds; three LTS (low temperature salts) unit beds, one expander, three ammonia valves, two oil valves, four water valves and connection pipes. Chemical working pair of MnCl 2 –CaCl 2 –NH 3 is selected. Since scroll expander is suitable for small type power generation system, it is chosen for expansion process. 4.8 kg MnCl 2 and 3.9 kg CaCl 2 impregnated in expanded natural graphite treated with sulfuric acid (ENG-TSA) are filled in the cogeneration system. Experimental results show that maximum cooling power 2.98 kW is able to be obtained while maximum shaft power is about 253 W with 82.3 W average value. The cogeneration system can be utilized for the heat source temperature lower than 170 °C. Total energy efficiency increases from 0.293 to 0.417 then decreases to 0.407 while exergy efficiency increases from 0.12 to 0.16. - Highlights: • A resorption system for power and refrigeration cogeneration is established and investigated. • ENG-TSA as the additive improves the heat and mass performance of composite adsorbent. • The highest shaft power and refrigeration power are 253 W and 2.98 kW, respectively. • Total energy efficiency of the system increases from 0.293 to 0.417 then decreases to 0.407.

  4. High efficiency cogeneration in sugar industry: opportunities, obstacles and possible solutions

    International Nuclear Information System (INIS)

    Govinda Rao, R.

    1994-01-01

    The main objective of this paper is to highlight the feasibility of bagasse based cogeneration systems within the framework of the existing laws and policies of the government, and to encourage the private sector and others to come forth to make good use of an extremely good investment climate. The feasible options worked out are based on financing from banks and other financial institutions at market rates. The other major objective is to establish the impediments to implement these projects. (author)

  5. 3D Analytical Model for a Tubular Linear Induction Generator in a Stirling Cogeneration System

    OpenAIRE

    Francois , Pierre; Garcia Burel , Isabelle; BEN AHMED , Hamid; Prevond , Laurent; Multon , Bernard

    2007-01-01

    International audience; This article sets forth a 3D analytical model of a tubular linear induction generator. In the intended application, the slot and edge effects as well as induced current penetration phenomena within the solid mover cannot be overlooked. Moreover, generator optimization within the present context of cogeneration has necessitated a systemic strategy. Reliance upon an analytical modeling approach that incorporates the array of typically-neglected phenomena has proven essen...

  6. Co-generation and reality Potential in Mexico; Potencial de cogeneracion y realidad en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Comision Nacional para el Ahorro de Energia (CONAE) (Mexico)

    2005-07-01

    This document deals with the Mexican use of co-generation -the efficient use of the energy- through the support offered by the Comision Nacional para el Ahorro de Energia (CONAE), since this is the agency in charge of fomenting the efficient use of energy by means of actions coordinated with diverse dependencies and organizations of the Administracion Publica Federal and with the governments of the federal entities as well as municipalities, social and private sectors. Among the subjects to be dealt are quality of the electrical and thermal energy, types of fuels that can be used in the co-generation project, the present situation of the co-generation in Mexico and the conditions for their development. [Spanish] Este documento analiza el uso de la cogeneracion en Mexico es decir, el uso eficiente de la energia a traves del apoyo que brinda la Comision Nacional para el Ahorro de Energia (CONAE) ya que es el organo encargado de fomentar la eficiencia en el uso de la energia mediante acciones coordinadas con las diversas dependencias y entidades de la Administracion Publica Federal y con los gobiernos de las entidades federativas y los municipios y, a traves de acciones concertadas, con los sectores social y privado. Se trataran temas como calidad de la energia electrica y termica, los tipos de combustibles que pueden utilizarse en el proyecto de cogeneracion, la situacion actual de la cogeneracion en Mexico y las ccondiciones para su desarrollo.

  7. Analysis of economic feasibility of sale of surplus electricity in cogeneration: case study

    International Nuclear Information System (INIS)

    Fodra, Marcelo; Esperancini, Maura Seiko Tsutsui

    2010-01-01

    The production of energy in large quantity and at competitive prices is crucial for economic development, which allied to the environmental question, has incentivated the use of renewable sources of energy. One of the most promising sources of renewable energy is the cogeneration from the residues of cane. Currently, the scenario for this kind of energy production is not consolidated, as production prices are not stable, inducing a risky situation for the environment. This work was aimed to study the economic viability of installing a main site for cogeneration of electricity, in a regional sugarcane factory located in the central region of Sao Paulo state that currently uses residues of sugar cane as fuel. The risk factor that was taken into consideration was the price paid for the MWh sold to the Chamber of Commerce of Electricity. The Monte Carlo Method was used to assess the risk factors for the analysis, by using of New Present Value (NPV), in a scenario that uses 20% of the initial investment made by the energy dealer. After the simulations were finished, considering the conditions used in this work, the project tends to be not feasible, as the behavior of the prices of cogenerated MWh are not sufficient for paying the initial investment and the operational costs. (author)

  8. Partners assume risks, lower finance costs of delayed coker-cogeneration project in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Alveal, E.D. [Petrox SA Refineria de Petroleo, Concepcion (Chile); Karpenski, M.J. [Foster Wheeler Power Systems Inc., Clinton, NJ (United States)

    1997-03-31

    Foster Wheeler Power Systems Inc., and its partners--Petrox SA Refineria de Petroleo and Empresa Nacional de Petroleo (ENAP), the Chilean national oil company--closed on the financing of Petropower Energia Limitada, a $237 million financed combination delayed coker-cogeneration facility. The facility is now under construction adjacent to Petrox`s 84,000 b/d Talcahuano refinery, near Concepcion. In addition to the low interest rate of 7.36%--only 170 basis points over the 10 year US Treasury yield--the project was rated investment-grade by Standard and Poor`s. The Petropower project also has the distinction of having the longest term--18 years--for any project financing in Latin America. The project is unique in other ways: it is the Republic of Chile`s first public/private partnership and also the first project to combine petroleum coking technology with cogeneration technology in a single project financing. The paper discusses risk assumption, the Petropower project, organization, delayed coker facility, hydrotreater unit, cogeneration facility, environmental assessment, Chile`s changing market, and project benefit.

  9. A mathematical model for the dynamic simulation of low size cogeneration gas turbines within smart microgrids

    International Nuclear Information System (INIS)

    Bracco, Stefano; Delfino, Federico

    2017-01-01

    Microturbines represent a suitable technology to be adopted in smart microgrids since they are characterized by affordable capital and maintenance costs, high reliability and flexibility, and low environmental impact; moreover, they can be fed by fossil fuels or biofuels. They can operate in cogeneration and trigeneration mode, thus permitting to attain high global efficiency values of the energy conversion system from primary energy to electrical and thermal energy; from the electrical point of view, microturbines can operate connected to the distribution grid but also in islanded mode, thus enabling their use in remote areas without electrification. The paper describes the mathematical model that has been developed to simulate in off-design and transient conditions the operation of a 65 kW el cogeneration microturbine installed within a smart microgrid. The dynamic simulation model is characterized by a flexible architecture that permits to simulate other different size single-shaft microturbines. The paper reports the main equations of the model, focusing on the architecture of the simulator and the microturbine control system; furthermore the most significant results derived from the validation phase are reported too, referring to the microturbine installed in the Smart Polygeneration Microgrid of the Savona Campus at the University of Genoa in Italy. - Highlights: • Dynamic simulation model of a cogeneration microturbine. • Off-design and transient performances of the microturbine. • Simulator validated on the Smart Polygeneration Microgrid at the Savona Campus.

  10. Feed-in tariff and market electricity price comparison. The case of cogeneration units in Croatia

    International Nuclear Information System (INIS)

    Uran, Vedran; Krajcar, Slavko

    2009-01-01

    In August 2007, the Government of the Republic of Croatia instituted a feed-in tariff system, requiring the Croatian Electricity Market Operator (HROTE) to off-take the electricity produced from renewable energy sources or cogeneration units fueled by natural gas. Analysis of the off-take electricity price range, which depends on the net electrical output and electricity market trends, indicates that it is more cost effective for cogeneration units greater than 1 MW to sell their electricity on the exchange market. This was confirmed by developing a mathematical model to calculate the cost-effectiveness ratio of a cogeneration unit. This ratio represents the relation between the profit spread, i.e. the difference between the profit generated from selling the electricity on the exchange market and the profit made from dispatching the electricity to HROTE, as well as the total investment costs. The model can be applied for changes in certain parameters, such as the net electrical output, volatility and spot electricity price. The Monte Carlo method is used to obtain the most probable cost-effectiveness ratio and average future electricity price. Together with these two economic parameters and market price analysis, it is possible to calculate and calibrate an acceptable off-take electricity price. (author)

  11. Achieving the economic potential for industrial cogeneration in Ontario: A financial perspective on electric utility policy

    International Nuclear Information System (INIS)

    Diemer, S.G.; Cain, S.R.

    1993-01-01

    The impact of private vs public ownership regimes on the magnitude of achievable industrial cogeneration capacity in Ontario is assessed. Estimates of technical and economic potential are presented for several industrial subsectors and heat demand categories, showing that nearly all of the technically feasible 7,600 MW is also economically efficient given a value of power of at least 4 cents/kWh in 1991 dollars. Using financial data and investment criteria specific to the two forms of ownership, the project evaluation model points to a significantly larger quantum of financial (achievable) potential with public rather than private development of industrial cogeneration. At avoided costs and associated buyback rates of 4 and 5 cents/kWh, the achievable cogeneration capacities are ca 2,400 and 7,600 MW under public ownership and 132 and 3,000 MW under private ownership. Ratepayer savings are significant: the full economic potential can be achieved through public ownership at a buyback rate of 5 cents/kWh; under private ownership, a comparable capacity requires a 6 cents buyback rate, reflecting additional ratepayer costs of nearly $600 million annually. 1 fig., 4 tabs

  12. Cogeneration from poultry industry wastes: Indirectly fired gas turbine application

    International Nuclear Information System (INIS)

    Bianchi, M.; Cherubini, F.; De Pascale, A.; Peretto, A.; Elmegaard, B.

    2006-01-01

    The availability of wet biomass as waste from a lot of industrial processes, from agriculture and farms and the need to meet the environmental standards force to investigate all options in order to dispose this waste. The possible treatments usually strongly depend on biomass characteristics, namely water content, density, organic content, heating value, etc. In particular, some of these wastes can be burnt in special plants, using them as energy supply for different processes. The study carried out with this paper is concerned with the promising utilization of the organic wastes from an existing poultry industry as fuel. Different plant configurations have been considered in order to make use of the oil and of the meat and bone meal, which are the by-products of the chicken cooking process. In particular, the process plant can be integrated with an energy supply plant, which can consist of an indirectly fired gas turbine. Moreover, a steam turbine plant or a simplified system for the supply of the only technological steam are investigated and compared. Thermodynamic and economic analysis have been carried out for the examined configurations in order to outline the basic differences in terms of energy savings/production and of return of the investments

  13. Cogeneration technology alternatives study. Volume 2: Industrial process characteristics

    Science.gov (United States)

    1980-01-01

    Information and data for 26 industrial processes are presented. The following information is given for each process: (1) a description of the process including the annual energy consumption and product production and plant capacity; (2) the energy requirements of the process for each unit of production and the detailed data concerning electrical energy requirements and also hot water, steam, and direct fired thermal requirements; (3) anticipated trends affecting energy requirements with new process or production technologies; and (4) representative plant data including capacity and projected requirements through the year 2000.

  14. Auxiliary services for petrochemistry. Cogeneration, thermocompression, steam distribution networks

    International Nuclear Information System (INIS)

    Vergerio, G.; Bruzzi, V.

    1999-01-01

    The article gives some guidelines for the choice of the most suitable energy vectors distributed in petrochemical plants and refineries for auxiliary services and for processes (mainly distillation). Conclusions are summed up in a diagram showing the most suitable heat sources and sinks for the various temperature ranges [it

  15. Analysis of electric power cogeneration using sugar cane bagasse; Uma analise da cogeracao de energia eletrica usando bagaco de cana-de-acucar

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Anna Cristina Barbosa Dias de

    1997-07-01

    Brazil impels its economy again. A development expected in 80 and 90 years it is real. This growth demands new technologies, new researches and bases that bear that growth. Electric power is in these bases, but Brazil is not ready for that. Electric power cogeneration possibility appears, using sugar cane bagasse. Alcohol and sugar plants have already that practice working with a low generation volume. With some investment this volume can be increased, adding about 10% to national energetic matrix. The aim of this work is to present a short time alternative for national electric matrix. It shows the energetic situation of the country, some experiences already implanted in some countries around the world and some options for equipment improvement used in alcohol and sugar plants. It is shown alternatives sources of electric power generation studied on Brazil, as well as the planning of National Energetic Program of ELETROBRAS. It analyses, in details, sugar cane bagasse use, which is used in Sao Paulo plants to generate electric power. Possible systems and troubles for its implantation in sugar and alcohol plants are discussed. (author)

  16. Cogenerational sources of energies and their allocating problem

    Directory of Open Access Journals (Sweden)

    Badida Miroslav

    1997-12-01

    Full Text Available Energy production in industrial communities consume a main part of primary raw materials and it is one of the sources of ecologicall impact. Electric power plants and warm produce plants are mostly important investment – consuming establishments with a long time of return, what stress along with the economical, predictional, logistical and environmental decision making aspect of their allocating. Already input of the mentioned aspects along with the price movement after the energy depression motivate a formation of new conception of combinated so-called items, which are able to use the energetic potential of fuels with a higher concurrent efficiency and, on the other hand, can reduce ecologic impacts of fossil combustion.

  17. Optimization cogeneration and use of biogas; Optimalisatie WKK en Biogasbenutting

    Energy Technology Data Exchange (ETDEWEB)

    Clevering-Loeffen, P.; Klaassens, N.; Schelleman, F.; Geraats, B.

    2011-12-15

    The Dutch local water authorities are producing biogas via sludge digestion installations, which is usually deployed in a CHP installation that produces energy for the sewage water treatment plant. However, new energy techniques are entering the market (ORC, fuel cell) while energy policy supports the production of green gas. Various studies have examined the sustainability and feasibility of these routes. This report examines the different options. It answers questions such as: (1) How can the operational management of CHP installations in sewage water treatment plants be improved; and (2) What is the most favorable route for biogas utilization in sewage water treatment plants [Dutch] De waterschappen in Nederland produceren biogas via slibvergistingsinstallaties, meestal benut in een WKK die elektriciteit voor de RWZI (rioolwaterzuiveringsinstallatie) produceert. Er komen echter nieuwe energietechnieken op de markt (ORC, brandstofcel) terwijl er vanuit het energiebeleid de productie van groen gas wordt gestimuleerd. In diverse studies zijn de duurzaamheid en de haalbaarheid van deze routes onderzocht. In dit rapport worden de verschillende mogelijkheden onderzocht. De vraagstelling voor deze studie is: (1)Hoe kan de bedrijfsvoering van WKK's bij RWZI's worden verbeterd; en (2) Wat is de meest gunstige route voor biogasbenutting bij RWZI's.

  18. Power generation options. Rehabilitation for life extension and cogeneration

    International Nuclear Information System (INIS)

    1993-01-01

    The first step in evaluating a life extension or upgrading project is to determine the project's economic benefit to the utility. A screening study should be performed for as many candidate plants as are available; two of the most useful screening tools for rapid economic analysis of life extension possibilities are: Present Worth Revenue Requirements (PWRR) Analysis, and Life Cycle Cost (LCC) Analysis. (Examples of both methods are discussed). PWRR analysis considers only the expenses associated with operation of a plant or electrical system, and the revenue required to meet those expenses. The total revenue that may be received from the system is not considered in the analysis. The estimated costs for a base case (usually no rehabilitation or life extension) is compared to the operating costs of various alternatives, calculated over an operating life span of several years, and reduced to a Present Worth value, usually for the year in which the study started. If the PWRR of any alternative is estimated to be less than the base case, then an investment in the alternative plant equal to or less than this differential is a preferred economic choice. PWRR analysis is useful if future systems development and future gross revenue to the utility is difficult to estimate; it is also useful when comparing like technologies when differences in fuel supply and fuel cost are minimal

  19. THE BREAKEVEN POINT GIVEN LIMIT COST USING BIOMASS CHP PLANT

    Directory of Open Access Journals (Sweden)

    Paula VOICU

    2015-06-01

    Full Text Available Biomass is a renewable source, non-fossil, from which can be obtained fuels, which can be used in power generation systems. The main difference of fossil fuels is the availability biomass in nature and that it is in continue "reproduction". The use its enable the use of materials that could be destined destruction, as a source of energy "renewable", though result with many ecological values. In this paper we will study, applying a calculation model in view optimal sizing of the cogeneration plant based on biomass, biomass cost limit for the net present value is zero. It will consider that in cogeneration systems and in heating peak systems using biomass. After applying the mathematical model for limit value of biomass cost will determine the nominal optimal coefficient of cogeneration, for which discounted net revenue value is zero. Optimal sizing of CHP plants based on using biomass will be given by optimum coefficient of cogeneration determined following the application of the proposed mathematical model.

  20. Theoretical analysis of the optimal configuration of co-generation systems and competitiveness of heating/cooling technologies

    Energy Technology Data Exchange (ETDEWEB)

    Akisawa, Atsushi; Miyazaki, Takahiko [Tokyo University of Agriculture and Technology, Institute of Symbiotic Science and Technology, 2-24-16 Nakacho, Koganei-shi, Tokyo 184-8588 (Japan); Kashiwagi, Takao [Tokyo Institute of Technology, Integrated Research Institute, 2-12-1 O-okayama, Meguro-ku, Tokyo 152-8550 (Japan)

    2010-10-15

    This study aims at exploiting optimal configurations of technologies combined with co-generation theoretically based on a linear optimization model. With the objective function defining primary energy consumption to be minimized, optimal solutions are derived analytically. They describe the technological configurations as well as associated conditions depending on their final energy demand. An interesting finding is that the essential parameters to determine the configurations are heat, cooling and steam demands normalized by power demand. The optimal solutions are also applied to investigate the competitiveness of co-generation related technologies. The optimal solutions yield critical conditions theoretically, which is useful to understand the priority of the technologies. A sensitivity analysis numerically indicates that absorption chillers can be superior to compression chillers even though the former has lower COP than the latter. Actual data of various types of co-generation are also examined to show the practical competitiveness. (author)

  1. Sustainable energy planning with efficient office buildings and cogeneration plants in Frankfurt am Main.

    Science.gov (United States)

    Friedel, Wendelin; Neumann, Werner

    2004-06-01

    Sustainable development of a city not only is determined through the amount of protected areas, but it is also an important task to integrate sustainable development in urban energy planning. In the last 10 years, many new areas for offices and residential buildings have been developed in Frankfurt am Main. In this context, the municipality has taken over a new role as organizer for the integrated energy planning. This article gives an overview of the achievements.

  2. Simulations of thermal-hydraulic processes in heat exchangers- station of the cogeneration power plant

    Energy Technology Data Exchange (ETDEWEB)

    Studovic, M.; Stevanovic, V.; Ilic, M.; Nedeljkovic, S. [Faculty of Mechanical Engineering of Belgrade (Croatia)

    1995-12-31

    Design of the long district heating system to Belgrade (base load 580 MJ/s) from Thermal Power Station `Nikola Tesla A`, 30 km southwest from the present gas/oil burning boilers in New Belgrade, is being conducted. The mathematical model and computer code named TRP are developed for the prediction of the design basis parameters of heat exchangers station, as well as for selection of protection devices and formulation of operating procedures. Numerical simulations of heat exchangers station are performed for various transient conditions: up-set and abnormal. Physical model of multi-pass, shell and tube heat exchanger in the station represented is by unique steam volume, and with space discretised nodes both for water volume and tube walls. Heat transfer regimes on steam and water side, as well as hydraulic calculation were performed in accordance with TEMA standards for transient conditions on both sides, and for each node on water side. Mathematical model is based on balance equations: mass and energy for lumped parameters on steam side, and energy balances for tube walls and water in each node. Water mass balance is taken as boundary/initial condition or as specified control function. The physical model is proposed for (s) heat exchangers in the station and (n) water and wall volumes. Therefore, the mathematical model consists of 2ns+2, non-linear differential equations, including equations of state for water, steam and tube material, and constitutive equations for heat transfer on steam and water side, solved by the Runge-Kutt method. Five scenarios of heat exchangers station behavior have been simulated with the TRP code and obtained results are presented. (author)

  3. Cogeneration approach for near shore internal combustion power plants applied to seawater desalination

    Energy Technology Data Exchange (ETDEWEB)

    Hung, T.C.; Shai, M.S. [I-Shou Univ., Dept. of Mechanical Engineering, Ta-Hsu Hsiang (Taiwan); Pei, B.S. [Tsing-Hua Univ., Dept. of Engineering and System Sciences, Tsing-Hua (Taiwan)

    2003-05-01

    The present study utilizes the waste heat streams, jacket water and exhaust gas from a diesel engine as the heat source for desalination of seawater. The seawater is preheated to a saturated state, and then, throttling and heat exchange processes are alternately employed for generation of fresh water. The exit brine is eventually crystallized to salt via the wind. In the evaluation, the temperature differences among the stages of the evaporator significantly influence the generation rate of fresh water. Accompanying the use of plastic heat exchangers, the brine related dirt problem could be avoided. The appropriate arrangement of the waste heat utilization could not only omit installation of the warm water discharge system but also prevent damage to the underwater ecology. The study successfully shows the feasibility of application of waste heat from combustion engines in the desalination of seawater. (Author)

  4. Cogeneration and Small Power Production Quarterly Report to the California Public Utilities Commission Fourth Quarter 1983

    Energy Technology Data Exchange (ETDEWEB)

    None

    1983-01-01

    At the end of 1983, the number of signed contracts and letter agreements for cogeneration and small power production projects was 305, with a total estimated nominal capacity of 2,389 MW. Of these totals, 202 projects, capable of producing 566 MW, are operational (Table A). A map indicating the location of operational facilities under contract with PG and E is provided as Figure A. Developers of cogeneration, solid waste, or biomass projects had signed 101 contracts with a potential of 1,408 MW. In total, 106 contracts and letter agreements had been signed with projects capable of producing 1,479 MW. PG and E also had under active discussion 29 cogeneration projects that could generate a total of 402 MW to 444 MW, and 13 solid waste or biomass projects with a potential of 84 MW to 89 MW. One contract had been signed for a geothermal project, capable of producing 80 MW. There were 7 solar projects with signed contracts and a potential of 37 MW, as well as 3 solar projects under active discussion for 31 MW. Wind farm projects under contract numbered 28, with a generating capability of 618 MW. Also, discussions were being conducted with 14 wind farm projects, totaling 365 MW. There were 100 wind projects of 100 kW or less with signed contracts and a potential of 1 MW, as well as 8 other small wind projects under active discussion. There were 59 hydroelectric projects with signed contracts and a potential of 146 MW, as well as 72 projects under active discussion for 169 MW. In addition, there were 31 hydroelectric projects, with a nominal capacity of 185 MW, that PG and E was planning to construct. Table B displays the above information. In tabular form, in Appendix A, are status reports of the projects as of December 31, 1983.

  5. Cogeneration and Small Power Production Quarterly Report to the California Public Utilities Commission First Quarter 1984

    Energy Technology Data Exchange (ETDEWEB)

    None

    1984-01-01

    At the end of the First Quarter of 1984, the number of signed contracts and letter agreements for cogeneration and small power production projects was 322, with a total estimated nominal capacity of 2,643 MW. Of these totals, 215 projects, capable of producing 640 MW, are operational. A map indicating the location of operational facilities under contract with PG and E is provided. Developers of cogeneration, solid waste, or biomass projects had signed 110 contracts with a potential of 1,467 MW. In total, 114 contracts and letter agreements had been signed with projects capable of producing 1,508 MW. PG and E also had under active discussion 35 cogeneration projects that could generate a total of 425 MW to 467 MW, and 11 solid waste or biomass projects with a potential of 94 MW to 114 MW. One contract had been signed for a geothermal project, capable of producing 80 MW. There were 7 solar projects with signed contracts and a potential of 37 MW, as well as 5 solar projects under active discussion for 31 MW. Wind farm projects under contract numbered 32, with a generating capability of 848 MW. Also, discussions were being conducted with 18 wind farm projects, totaling 490 MW. There were 101 wind projects of 100 kW or less with signed contracts and a potential of 1 MW, as well as 6 other small wind projects under active discussion. There were 64 hydroelectric projects with signed contracts and a potential of 148 MW, as well as 75 projects under active discussion for 316 MW. In addition, there were 31 hydroelectric projects, with a nominal capacity of 187 MW, that Pg and E was planning to construct.

  6. Analysis of an optimal resorption cogeneration using mass and heat recovery processes

    International Nuclear Information System (INIS)

    Lu, Yiji; Wang, Yaodong; Bao, Huashan; Yuan, Ye; Wang, Liwei; Roskilly, Anthony Paul

    2015-01-01

    Highlights: • Resorption cogeneration for electricity and refrigeration generation. • Mass and heat recovery to further improve the performance. • The first and second law analysis. - Abstract: This paper presents an optimised resorption cogeneration using mass and heat recovery to improve the performance of a novel resorption cogeneration fist proposed by Wang et al. This system combines ammonia-resorption technology and expansion machine into one loop, which is able to generate refrigeration and electricity from low-grade heat sources such as solar energy and industrial waste heat. Two sets of resorption cycle are designed to overcome the intermittent performance of the chemisorption and produce continuous/simultaneous refrigeration and electricity. In this paper, twelve resorption working pairs of salt complex candidates are analysed by the first law analysis using Engineering Equation Solver (EES). The optimal resorption working pairs from the twelve candidates under the driven temperature from 100 °C to 300 °C are identified. By applying heat/mass recovery, the coefficient of performance (COP) improvement is increased by 38% when the high temperature salt (HTS) is NiCl 2 and by 35% when the HTS is MnCl 2 . On the other hand, the energy efficiency of electricity has also been improved from 8% to 12% with the help of heat/mass recovery. The second law analysis has also been applied to investigate the exergy utilisation and identify the key components/processes. The highest second law efficiency is achieved as high as 41% by the resorption working pair BaCl 2 –MnCl 2 under the heat source temperature at 110 °C.

  7. Performance assessment of cogeneration and trigeneration systems for small scale applications

    International Nuclear Information System (INIS)

    Angrisani, Giovanni; Akisawa, Atsushi; Marrasso, Elisa; Roselli, Carlo; Sasso, Maurizio

    2016-01-01

    Highlights: • Indices and methods to assess the performance of polygeneration systems. • Index to evaluate the economic feasibility of trigeneration system is introduced. • Thermo-economic analysis is performed considering three commercial cogenerators. • Sensitivity analysis varying reference electric efficiency for European Countries. • Sensitivity analysis varying environmental and economic parameters. - Abstract: Cogeneration and trigeneration systems can contribute to the reduction of primary energy consumption and greenhouse gas emissions in residential and tertiary sectors, by reducing fossil fuels demand and grid losses with respect to conventional systems. To evaluate the performance of these systems, several indices and assessment methodologies can be used, due to the high complexity of such systems, which can consist of several energy conversion devices and can perform bidirectional interactions with external electric and thermal grids. In this paper, a review of the available indices and methodologies to assess the performances of polygeneration systems is provided. An index (TSS tri ) aimed to assess the economic feasibility of a trigeneration system is also introduced and discussed. This activity started in the framework of the International Energy Agency Annex 54 project (“Integration of Micro-Generation and Related Energy Technologies in Buildings”), where research groups shared their expertise about methods applied in each Country to evaluate the performance of polygeneration systems. It was concluded that a thermo-economic analysis comparing the performance of a polygeneration system with those of a reference benchmark scenario, is a very suitable assessment method. Some of the reviewed methodologies are then applied to small scale commercial cogenerators. The sensitivity analysis is performed considering different reference average values of electric efficiency, unitary natural gas and electricity prices, and emission factors for

  8. Advanced cogeneration and absorption chillers potential for service to Navy bases. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.; Butcher, T.A.; Leigh, R.W.; McDonald, R.J.; Pierce, B.L.

    1996-04-01

    The US military uses millions of Btu`s of thermal energy to heat, cool and deliver process thermal energy to buildings on military bases, much of which is transmitted through a pipeline system incorporating thousands of miles of pipe. Much of this pipeline system is in disrepair and is nearing the end of its useful life, and the boilers which supply it are old and often inefficient. In 1993, Brookhaven National Laboratory (BNL) proposed to SERDP a three-year effort to develop advanced systems of coupled diesel cogenerators and absorption chillers which would be particularly useful in providing a continuation of the services now provided by increasingly antiquated district systems. In mid-February, 1995, BNL learned that all subsequent funding for our program had been canceled. BNL staff continued to develop the Program Plan and to adhere to the requirements of the Execution Plan, but began to look for ways in which the work could be made relevant to Navy and DoD energy needs even without the extensive development plan formerly envisioned. The entire program was therefore re-oriented to look for ways in which small scale cogeneration and absorption chilling technologies, available through procurement rather than development, could provide some solutions to the problem of deteriorated district heating systems. The result is, we believe, a striking new approach to the provision of building services on military bases: in many cases, serious study should be made of the possibility that the old district heating system should be removed or abandoned, and small-scale cogenerators and absorption chillers should be installed in each building. In the remainder of this Summary, we develop the rationale behind this concept and summarize our findings concerning the conditions under which this course of action would be advisable and the economic benefits which will accrue if it is followed. The details are developed in the succeeding sections of the report.

  9. Combined cogeneration equipment containing gas turbine using low sulphur heavy stock as fuel

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, Goro; Ishiki, Katsuhiko

    1988-03-10

    This paper describes the combined cogeneration in Chemical and Plastics Co. Madras (India) which uses low sulphur heavy stock (LSHS) as a fuel. By the combined cogeneration of gas turbine and boiler steam turbine power generation, the exhaust from the steam turbine is supplied to the factory as a process steam. This equipment has a capacity of 4835 kW in overall generation power and 23.5 tons/hrs. in steam evaporation. The gas turbine system is equipped with an axial-flow, 11 step compressor, an axial flow, 4 step turbine, and a single-can back flow combustor fixed to the intermediate casing. The temperature of the exhaust from the gas turbine is 542/sup 0/C. Low quality LSHS when burned exerts no influence on the service life of the turbine blades. The boiler is a horizontal bent pipe, forced circulation type, and the steam turbine is a back pressure control type. The fuel is treated with a horizontal, two drum, electrostatic separator to which a demulsifier is supplied, to be separated into oil and water. As to the vanadium salts contained in the fuels, a chemical liquid containing MgO as a major ingredient is added to the fuel prior to the combustion. Thereby, the melting temperature of the vanadium oxide is enhanced, which serves for prevention of the melting and adhesion of the vanadium oxide to the gas turbine. LSHS is a residual oil produced by the ordinary pressure distillation of India-produced crude oil, has a sulphur content of 1.75%, and is solid at room temperature. Attention should be paid to clogging of the pipings. The overall efficiency is 80%. The combined cogeneration can be coordinated with load variations of 10 - 20%. (12 figs, 1 tab)

  10. 250 MW single train CFB cogeneration facility. Annual report, October 1993--September 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-01

    This Technical Progress Report (Draft) is submitted pursuant to the Terms and Conditions of Cooperative Agreement No. DE-FC21-90MC27403 between the Department of Energy (Morgantown Energy Technology Center) and York County Energy Partners, L.P. a wholly owned project company of Air Products and Chemicals, Inc. covering the period from January 1994 to the present for the York County Energy Partners CFB Cogeneration Project. The Technical Progress Report summarizes the work performed during the most recent year of the Cooperative Agreement including technical and scientific results.

  11. Cogeneration and Small Power Production Quarterly Report to the California Public Utilities Commission. Second Quarter 1984

    Energy Technology Data Exchange (ETDEWEB)

    None

    1984-01-01

    At the end of the Second Quarter of 1984, the number of signed contracts and letter agreements for cogeneration and small power production projects was 334, with total estimated nominal capacity of 2,876 MW. Of these totals, 232 projects, capable of producing 678 MW, are operational (Table A). A map indicating the location of operational facilities under contract with PG and E is provided as Figure A. Developers of cogeneration projects had signed 80 contracts with a potential of 1,161 MW. Thirty-three contracts had been signed for solid waste/biomass projects for a total of 298 MW. In total, 118 contracts and letter agreements had been signed with cogeneration, solid waste, and biomass projects capable of producing 1,545 MW. PG and E also had under active discussion 46 cogeneration projects that could generate a total of 688 MW to 770 MW, and 13 solid waste or biomass projects with a potential of 119 MW to 139 MW. One contract had been signed for a geothermal project, capable of producing 80 MW. Two geothermal projects were under active discussion for a total of 2 MW. There were 8 solar projects with signed contracts and a potential of 37 MW, as well as 4 solar projects under active discussion for 31 MW. Wind farm projects under contract numbered 34, with a generating capability of 1,042 MW, Also, discussions were being conducted with 23 wind farm projects, totaling 597 MW. There were 100 wind projects of 100 kW or less with signed contracts and a potential of 1 MW, as well as 7 other small wind projects under active discussion. There were 71 hydroelectric projects with signed contracts and a potential of 151 MW, as well as 76 projects under active discussion for 505 MW. In addition, there were 18 hydroelectric projects, with a nominal capacity of 193 MW, that PG and E was planning to construct. Table B displays the above information. Appendix A displays in tabular form the status reports of the projects as of June 30, 1984.

  12. Cogeneration and beyond: The need and opportunity for high efficiency, renewable community energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Gleason, T.C.J.

    1992-06-01

    The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.

  13. Cogeneration and beyond: The need and opportunity for high efficiency, renewable community energy systems

    International Nuclear Information System (INIS)

    Gleason, T.C.J.

    1992-06-01

    The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems

  14. Optimal design of a solar-hybrid cogeneration cycle using Cuckoo Search algorithm

    International Nuclear Information System (INIS)

    Khoshgoftar Manesh, M.H.; Ameryan, M.

    2016-01-01

    Highlights: • Effective time-saving procedure. • Using simple parallel computing exergoeconomic optimization. • Optimum design of solar-hybrid cogeneration cycle based on the Cuckoo Search. • Appears effective in optimizing thermodynamic cycles. - Abstract: In this paper optimum design of solar-hybrid cogeneration cycle based on the Cuckoo Search (CS) algorithm is presented. The CS is one of the recently developed population based algorithms inspired by the behavior of some cuckoo species together via the Levy flight behavior of some birds and fruit flies. Moreover, solar power tower technology is practical for utilization in conventional fossil fired power cycles, in part because it can achieve temperatures as high as 1000 °C. An exergoeconomic optimization is reported here of a solar-hybrid cogeneration cycle. Modifications are applied to the well-known the prescribed simple cogeneration (CGAM) problem through hybridization by appropriate heliostat field design around the power tower to meet the plant’s annual demand. The hybrid cycle is optimized utilizing a CS and compared with the results of the Genetic Algorithm (GA) in Matlab toolbox. Considering exergy efficiency and product cost as objective functions, and principal variables as decision variables, the optimum point is determined. The corresponding optimum decision variables are set as inputs of the system and the technical results are a 48% reduction in fuel consumption which leads to a corresponding decrease in CO 2 emissions and a considerable decrease in chemical exergy destruction as the main source of irreversibility. In the analyses, the net power generated is fixed at 30 MW with a marginal deviation in order to compare the results with the conventional cycle. Despite the technical advantages of this scheme, the total product cost rises significantly (by about 87%), which is an expected economic outcome. Effective time-saving procedure using simple parallel computing, as well as utilizing

  15. Anatomy of a cogeneration deal : natural gas contracts and regulatory issues

    International Nuclear Information System (INIS)

    Brett, J.T.

    1999-01-01

    The special features of gas contracts for cogeneration projects were discussed. It was recommended that a gas power purchase contract should be entered early in a project development cycle to justify requests for new pipeline facilities. Issues regarding buyer's commitments, market prices, and volumes were also discussed. In the event of failure to deliver, the contract should include provisions which would make it possible to source gas elsewhere, terminate the contract or seek damages. This paper also discussed various pricing provisions in a gas commodity contract, security of supplies, gas transportation arrangements, regulatory considerations, outstanding issues, and IMO (independent market operator) requirements

  16. Nuclear reactor PBMR and cogeneration; Reactor nuclear PBMR y cogeneracion

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez S, J. R.; Alonso V, G., E-mail: ramon.ramirez@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    In recent years the nuclear reactor designs for the electricity generation have increased their costs, so that at the moment costs are managed of around the 5000 US D for installed kw, reason for which a big nuclear plant requires of investments of the order of billions of dollars, the designed reactors as modular of low power seek to lighten the initial investment of a big reactor dividing the power in parts and dividing in modules the components to lower the production costs, this way it can begin to build a module and finished this to build other, differing the long term investment, getting less risk therefore in the investment. On the other hand the reactors of low power can be very useful in regions where is difficult to have access to the electric net being able to take advantage of the thermal energy of the reactor to feed other processes like the water desalination or the vapor generation for the processes industry like the petrochemical, or even more the possible hydrogen production to be used as fuel. In this work the possibility to generate vapor of high quality for the petrochemical industry is described using a spheres bed reactor of high temperature. (Author)

  17. JV 38-APPLICATION OF COFIRING AND COGENERATION FOR SOUTH DAKOTA SOYBEAN PROCESSORS

    Energy Technology Data Exchange (ETDEWEB)

    Darren D. Schmidt

    2002-11-01

    Cogeneration of heat and electricity is being considered by the South Dakota Soybean Processors for its facility in Volga, South Dakota, and a new facility to be located in Brewster, Minnesota. The Energy & Environmental Research Center has completed a feasibility study, with 40% funding provided from the U.S. Department of Energy's Jointly Sponsored Research Program to determine the potential application of firing biomass fuels combined with coal and comparative economics of natural gas-fired turbines. Various biomass fuels are available at each location. The most promising options based on availability are as follows. The economic impact of firing 25% biomass with coal can increase return on investment by 0.5 to 1.5 years when compared to firing natural gas. The results of the comparative economics suggest that a fluidized-bed cogeneration system will have the best economic performance. Installation for the Brewster site is recommended based on natural gas prices not dropping below a $4.00/MMBtu annual average delivered cost. Installation at the Volga site is only recommended if natural gas prices substantially increase to $5.00/MMBtu on average. A 1- to 2-year time frame will be needed for permitting and equipment procurement.

  18. Cogeneration in Mexico: Weaknesses, Threats, strengths and opportunities; Cogeneracion en Mexico: Debilidades, amenazas, fortalezas y oportunidades

    Energy Technology Data Exchange (ETDEWEB)

    Elizalde Baltierra, Alberto; Garcia Pelaez, Juan [Programa Universitario de Energia, UNAM (Mexico)

    1997-07-01

    In this paper the strategies are formulated and evaluated, taking into account the internal and external aspects of the cogeneration in Mexico that foment their development in the medium term (two or four years). In the formulation of strategies a matrix DAFO (Weaknesses, Threats, Strengths and Opportunities) is employed and in the evaluation is applied the procedure of analytical hierarchical structuring. The future on the cogeneration in the next years will depend on diverse factors, among which can be mentioned: the legal frame; the financial situation of the interested companies; the outsourcing of financing; the prices of the electricity and fuels, as well as their availability, among others. [Spanish] En este trabajo se formulan y evaluan estrategias que, tomando en cuenta los aspectos internos y externos de la cogeneracion en Mexico, fomenten su desarrollo en el mediano plazo (dos o cuatro anos). En la formulacion de estrategias se emplea la matriz DAFO (Debilidades, Amenazas, Fortalezas y Oportunidades) y en la evaluacion se aplica el procedimiento de jerarquizacion analitica. El futuro de la cogeneracion en los proximos anos dependera de diversos factores, entre los que se pueden mencionar: el marco legal; la situacion financiera de las empresas interesadas; las fuentes externas de financiamiento; los precios de la electricidad y de los combustibles, asi como su disponibilidad, entre otros.

  19. Thermodynamic Investigation of a Shared Cogeneration System with Electrical Cars for Northern Europe Climate

    Directory of Open Access Journals (Sweden)

    Giulio Vialetto

    2017-12-01

    Full Text Available Transition to alternative energy systems is indicated by EU Commission as a suitable path to energy efficiency and energy saving in the next years. The aims are to decrease greenhouses gases emissions, relevance of fossil fuels in energy production and energy dependence on extra-EU countries. These goals can be achieved increasing renewable energy sources and/or efficiency on energy production processes. In this paper an innovative micro-cogeneration system for household application is presented: it covers heating, domestic hot water and electricity demands for a residential user. Solid oxide fuel cells, heat pump and Stirling engine are utilised as a system to achieve high energy conversion efficiency. A transition from traditional petrol cars to electric mobility is also considered and simulated here. Different types of fuel are considered to demonstrate the high versatility of the simulated cogeneration system by changing the pre-reformer of the fuel cell. Thermodynamic analysis is performed to prove high efficiency with the different fuels.

  20. Development and implementation of a 600-MW natural gas cogeneration project - a financial case history

    International Nuclear Information System (INIS)

    Quinn, N.K.; Sherrill, R.L.

    1992-01-01

    In February 1990, General Electric Capital Corporation (GECC), through its wholly owned subsidiary, General Electric Power Funding Corporation (GEPFC), provided a number of commitments to a partnership (the Partnership) formed by a company that develops, owns, and operates cogeneration facilities to fund the development, construction, and permanent debt and equity financing of a 614 megawatt (M) cogeneration facility (the Project) to be located near a large refinery in the northeastern United States. The Project is unusual both for the magnitude of its natural gas requirements and for its contractual configuration. The Project's entire transportation needs and a substantial portion of its gas requirements will be met by a joint venture between two local gas distribution companies (the Joint Venture), one of which is a large gas-consuming utility in the eastern United States. The Project's power purchase customer, (the Utility Host), is another very large gas-consuming utility. Thus, the fuel cost recovery of the Project is determined by the Utility Host's gas costs while its actual bill for fuel will be heavily influenced by the Joint Venture's gas commodity and transportation costs. Therefore, in appraising the credit quality of the Project's proposed fuel supply arrangements, the key issue to be answered is: Are the Project's natural gas supply and transportation arrangements compatible with the fuel cost recovery provisions of the power sales agreement with the Utility Host? If so, then the sensitivity of the Project's financing to adverse gas price movements would be minimized

  1. Nova Scotia electricity market : frameworks for renewable energy contracting and cogeneration contracting : discussion document

    International Nuclear Information System (INIS)

    2006-01-01

    The recent Electricity Marketplace Governance Committee of Nova Scotia report issued a number of recommendations regarding renewable and cogeneration sales to retail consumers, as well as recommendations for top-up, spill rates and back-up rates to complement the operation of independent generating facilities. This discussion paper examined issues which need to be addressed in order to implement the recommendations. The discussion paper also included recommendations relating to the purchase of cogeneration output by the Nova Scotia Power Inc. (NSPI) under long term power purchase agreements. The aim of the paper was to provide a basis for the further discussion of issues in preparation for the development of future rules and regulations. The first part of the document identified ways for buyers and sellers to arrange contracts, as well as issues that need to be addressed at the institutional level to enable arrangements. Options for financial contracts and physical contracts were reviewed.The second part of the document examined pricing issues in the context of both financial and physical contract arrangements. Resolutions for both sets of options were proposed. Energy pricing principles were reviewed, as well as various pricing options and issues related to the analysis of price requirements. It was concluded that in order to support the safe, reliable and economic supply of electricity, the design of the electricity market should enable maximum flexibility in contractual arrangements and facilitate competition in ways that do not harm other parties

  2. Thermodynamic analysis and experimental investigation of a Solo V161 Stirling cogeneration unit

    International Nuclear Information System (INIS)

    Rogdakis, E.D.; Antonakos, G.D.; Koronaki, I.P.

    2012-01-01

    In order to investigate the Stirling engine implementation technology, a Solo Stirling Engine V161 cogeneration module has been installed at the Laboratory of Applied Thermodynamics of National Technical University of Athens. A special thermodynamic analysis of the engine's performance has been conducted introducing and utilizing specially designed computing codes along with the thermal balance study of the unit. Measurements were conducted under different operational conditions concerning various heat load stages of the engine, working pressure, as well as electric power production. Analysis of the experimental results has shown that the overall performance of the Stirling unit proved very promising and quite adequate for various areal applications, equally competing with other CHP systems. The performance of the unit experienced significant stability all over the operating range. The power stand ratio 0.35 differentiates Stirling cogeneration units from others that use diverging technologies significantly. The energy savings using a Stirling CHP unit, in respect to the concurrent use of a thermal and an electrical system at the same equivalent power has revealed 36.8%. -- Highlights: ► Thermodynamic analysis of an a-type Stirling engine. ► Development of generated electrical and thermal power of the m-CHP Solo Stirling Unit to engine's load comparison. ► Stirling m-CHP until heat balance analysis. ► Evaluation of the Solo Stirling V161 unit efficiency.

  3. Cogeneration of hydrogen and methane from glucose to improve energy conversion efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Binfei; Cheng, Jun; Zhou, Junhu; Song, Wenlu; Cen, Kefa [State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027 (China)

    2008-10-15

    In order to reutilize the residual solutions derived from hydrogen production and increase the energy conversion efficiency, a novel process of cogenerating hydrogen and methane from glucose using a two-phase anaerobic fermentation process was proposed and investigated. The effects of substrate concentration, weight ratio of inoculation to substrate, pH value and nutrient medium on hydrogen production were studied. The maximum specific hydrogen yield is 2.75 mol H{sub 2}/mol glucose when the initial glucose concentration is 1%, the weight ratio of inoculation to substrate is 2:1 and the pH value is 6. The residual solutions derived from hydrogen production were reused to produce methane by methanogen in another reactor. The maximum specific methane yield is 2.13 mol CH{sub 4}/mol glucose when the reutilization rates of ethanol, acetic acid, butyric acid, valeric acid, and caproic acid are all above 90%. The cogeneration process can dramatically increase the energy conversion efficiency from 23% (hydrogen only production) to 82%. (author)

  4. Opportunities for saving energy by means of cogeneration in Vegetales's Cannery of Sancti Spiritus.

    Directory of Open Access Journals (Sweden)

    Arturo Alberto Clemente Corujo

    2010-09-01

    Full Text Available This work analyzes the viability to install a system of cogeneration and to save energy at Vegetales's Cannery. The type of more convenient arrangement according to the conditions of the industry was defined. The magnitude of necessary investment, the equipment required, and also the additional quantity of diesel were determined for the correct operation of the project. It was considered the steam production and the consumptions of combustible oil and the electricity in the year 2008. As a primary motor was each engine Volvo of 3 existent generating sets. A minimal time of 4 daily hours during 300 days was calculated to work annually and they analyzed the necessary investments for expected benefits. The economic evaluation has as possitive results: a VAN of $192 646,89's and 36 %'s TIR. The cogeneration scheme more convenient is with Topping cycle. The necessary investment is about $144 000 and for having profitability it is necessary to work the same amount of hours from 6 to 10 p.m. that in the rest of a day.

  5. The economic potential of bagasse cogeneration as CDM projects in Indonesia

    International Nuclear Information System (INIS)

    Restuti, Dewi; Michaelowa, Axel

    2007-01-01

    Surplus bagasse in Indonesian sugar mills is potential for grid-connected electricity-generating projects under Clean Development Mechanism (CDM) scheme. In addition, it is further perceived to considerably support the efforts to address prevailing crises in domestic sugar industry and power generation sector. This paper aims at analyzing the economic potential of bagasse cogeneration as CDM projects in Indonesia with the main deliverables of total emission reductions per year and Certified Emission Reduction (CER) earnings. The analysis was made by following the applicable methodologies and based on publicly available data from official and other sources on the websites. The results show that with the electricity displacement potential at 260,253 MWh, Indonesia could generate Greenhouse Gas (GHG) emission reductions as much as 240,774 (large scale) or 198,177 tCO 2 (small scale) per annum from the recently-employed low efficiency cogeneration leading to the earnings of about US$1.36 or 1.12 million, respectively. Out of 6 regional grids where the electricity from the project activities can be grid-connected, the primary emission reductions potentials are encountered in Java-Bali and Southern Sumatera grids. Additionally, various barriers in technical, institutional, financial, and other aspects have been identified as the justifications to pass the additionality test

  6. Final report of phase 2 'Mini-cogeneration in the flower bulb industry'; Eindrapportage Fase 2 'Mini-WKK in de bloembollensector'

    Energy Technology Data Exchange (ETDEWEB)

    Koolwijk, E. [Cogen Projects, Driebergen-Rijsenburg (Netherlands); Smailbegovic, N. [SenterNovem, Utrecht (Netherlands)

    2009-09-15

    Phase 2 of the project 'mini-cogeneration in the flower bulb industry' is the sequel to the report 'mini-cogeneration in the flower bulb industry. Use of cogeneration in the cultivation and hot bed of tulip and hyacinth', Addressing the incentivisation of the use of cogeneration in the sector and working toward realizing a number of demonstration projects. To this end it is necessary that potential investors are given insight in the feasibility of cogeneration at their business and that their enthusiasm is kindled for the use of cogeneration. This was done by disseminating information in the flower bulb industry about the opportunities of cogeneration and by informing growers about technique, economy and points of interest. [Dutch] Fase 2 van het project 'Mini- WKK in de bloembollensector' is een vervolg op het rapport 'Mini-wkk in de bloembollensector. Toepassing van wkk bij teelt en broei van tulp en hyacint' en richt zich op het stimuleren van de toepassing van WKK in de sector en toewerken naar realisatie van een aantal demonstratieprojecten. Daartoe is het noodzakelijk dat potentiele investeerders inzicht krijgen over de haalbaarheid van WKK op hun bedrijf en geenthousiasmeerd worden voor het gebruik van WKK. Dit is gedaan door informatie in de bollensector te verspreiden over de mogelijkheden van WKK en telers te informeren over techniek, economie en aandachtspunten.

  7. Potential benefits of thermal energy storage in the proposed Twin Cities district heating-cogeneration system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, C.F.

    1979-10-01

    A new, large, cogeneration-district heating system has been proposed for the Twin Cities area, using hot water in a closed-loop system. The proposed system, as described by Studsvik Energiteknik AB of Sweden, does not employ thermal energy storage (TES). Four cases have been developed, describing system configurations which would employ TES, to evaluate the potential benefits of incorporating annual-cycle TES into the Twin Cities system. The potential benefits are found to be substantial, confirming results of earlier, generic studies of aquifer TES. The reference (Studsvik) system employs oil-fired boilers to supplement cogenerated heat, for handling peak loads and providing standby reserve. TES can serve the same function, with net energy savings in spite of heat losses during storage, by making it possible to operate the cogeneration equipment at higher capacity factors. Coal replaces oil as the fuel consumed. Energy savings of the reference system are impressive; energy savings with TES are 2 to 22% better. Capital cost requirements for boilers, cogeneration equipment, and pipelines are reduced by $66 to $258 million. The breakeven capital cost of TES is estimated to range from $43 to $76 per kilowatt peak thermal input to or withdrawal from aquifer TES. A factor in evaluating the breakeven operating cost of TES is the $14 to $31 million per year saving in cost of fuel. Abatement of air pollution and thermal pollution are concomitant benefits.

  8. Impact assessment of intermediate processes of steelmaking in electricity cogeneration of steel mill companies//Evaluación del impacto de los procesos intermedios de la producción de acero en la cogeneración de electricidad de la industria siderúrgica

    Directory of Open Access Journals (Sweden)

    Eder Quental-de-Araújo

    2015-09-01

    production of intermediate processes in cogeneration. It was noted that some processes such as coke oven, blast furnace and steelmaking have a direct relationship between increased production and cogeneration capacity, but in other cases such as sinter plant and rolling mill the increase of production causes a decrease in the availability of fuels for thermoelectric power plant. Keywords: steel mill, forecast, cogeneration, process gases, intermediate processes.

  9. The HTScroll project - Innovative cogeneration system with a high-temperature turbine; Projet HTScroll. Nouveau systeme de cogeneration a turbine spirale haute temperature - Rapport final

    Energy Technology Data Exchange (ETDEWEB)

    Kane, M.; Cretegny, D.; Maquet, J. [ENEFTECH Innovation SA, Swiss Federal Institute of Technology EPFL, Laboratoire d' Energetique Industrielle LENI, EPFL Science Park PSE, Lausanne (Switzerland); Favrat, D. [Swiss Federal Institute of Technology EPFL, Lausanne (Switzerland)

    2009-10-15

    This final report for the Swiss Federal Office of Energy (SFOE) proposes an alternative for micro-cogeneration based on a scroll expander to produce electricity from relatively low-temperature heat sources (less than 250 {sup o}C), thus allowing the use of renewable energy resources such as biomass, solar thermal and geothermal energy. The authors note that such a system could produce cost-effective 'green' electricity as well as heat (near 60 {sup o}C) for space heating and domestic hot-water preparation. The design and validation of a new concept for a double-stage scroll expander ('HT-Scroll') operating at high and low pressures and high temperatures is discussed. Design, modelling and construction of a 5 kW unit have been carried out. The organic fluid Rankine Cycle concept is described, the modelling of the turbine, its construction and tests carried out are discussed. Problems encountered and future work are noted.

  10. Study on the Effect of a Cogeneration System Capacity on its CO2 Emissions

    Science.gov (United States)

    Fonseca, J. G. S., Jr.; Asano, Hitoshi; Fujii, Terushige; Hirasawa, Shigeki

    With the global warming problem aggravating and subsequent implementation of the Kyoto Protocol, CO2 emissions are becoming an important factor when verifying the usability of cogeneration systems. Considering this, the purpose of this work is to study the effect of the capacity of a cogeneration system on its CO2 emissions under two kinds of operation strategies: one focused on exergetic efficiency and another on running cost. The system meets the demand pattern typical of a hospital in Japan, operating during one year with an average heat-to-power ratio of 1.3. The main equipments of the cogeneration system are: a gas turbine with waste heat boiler, a main boiler and an auxiliary steam turbine. Each of these equipments was characterized with partial load models, and the turbine efficiencies at full load changed according to the system capacity. Still, it was assumed that eventual surplus of electricity generated could be sold. The main results showed that for any of the capacities simulated, an exergetic efficiency-focused operational strategy always resulted in higher CO2 emissions reduction when compared to the running cost-focused strategy. Furthermore, the amount of reduction in emissions decreased when the system capacity decreased, reaching a value of 1.6% when the system capacity was 33% of the maximum electricity demand with a heat-to-power ratio of 4.1. When the system operated focused on running cost, the economic savings increased with the capacity and reached 42% for a system capacity of 80% of maximum electricity demand and with a heat-to-power ratio of 2.3. In such conditions however, there was an increase in emissions of 8.5%. Still for the same capacity, an exergetic efficiency operation strategy presented the best balance between cost and emissions, generating economic savings of 29% with a decrease in CO2 emissions of 7.1%. The results found showed the importance of an exergy-focused operational strategy and also indicated that lower capacities

  11. Evaluation of the environmental sustainability of different waste-to-energy plant configurations.

    Science.gov (United States)

    Lombardi, Lidia; Carnevale, Ennio A

    2018-03-01

    Residual municipal solid waste (MSW) has an average lower heating value higher than 10GJ/Mg in the EU, and can be recovered in modern Waste-to-Energy (WtE) plants, producing combined heat and power (CHP) and reaching high levels of energy recovery. CHP is pinpointed as the best technique for energy recovery from waste. However, in some cases, heat recovery is not technically feasible - due to the absence of a thermal user (industrial plant or district heating) in the vicinity of the WtE plant - and power production remains the sole possibility. In these cases, there are some challenges involved in increasing the energy performance as much as possible. High energy recovery efficiency values are very important for the environmental sustainability of WtE plants. The more electricity and heat is produced, the better the saving of natural resources that can be achieved. Within this frame, the aim of this work is to carry out an environmental assessment, through Life Cycle Assessment, of an MSW WtE plant, considering different sizes and operated in different ways, from power production only to full cogeneration. The main assumption is that the electric conversion efficiency increases as the plant size increases, introducing technical improvements thanks to the economies of scale. Impact assessment results were calculated using ReCiPe 2008 methods. The climate change indicator is positive when the WtE plant is operated in power production only mode, with values decreasing for the increasing size. Values for the climate change are negative when cogeneration is applied, requiring increasing cogeneration ratios for decreasing size. Similarly, the fossil fuel depletion indicator benefits from increase of both the plant size and the cogeneration rate, but it is always negative, meaning that the residual MSW burning with energy recovery always provides a saving of fossil primary energy. Other indicator values are in general negative and are also beneficially affected by

  12. Analysis of engineering cycles power, refrigerating and gas liquefaction plant

    CERN Document Server

    Haywood, R W

    1991-01-01

    Extensively revised, updated and expanded, the fourth edition of this popular text provides a rigorous analytical treatment of modern energy conversion plant. Notable for both its theoretical and practical treatment of conventional and nuclear power plant, and its studies of refrigerating and gas-liquefaction plant. This fourth edition now includes material on topics of increasing concern in the fields of energy 'saving' and reduction of environmental pollution. This increased coverage deals specifically with the following areas: CHP (cogeneration) plant, studies of both gas and coal burning p

  13. Life cycle assessment of an intensive sewage treatment plant in Barcelona (Spain) with focus on energy aspects.

    Science.gov (United States)

    Bravo, L; Ferrer, I

    2011-01-01

    Life Cycle Assessment was used to evaluate environmental impacts associated to a full-scale wastewater treatment plant (WWTP) in Barcelona Metropolitan Area, with a treatment capacity of 2 million population equivalent, focussing on energy aspects and resources consumption. The wastewater line includes conventional pre-treatment, primary settler, activated sludge with nitrogen removal, and tertiary treatment; and the sludge line consists of thickening, anaerobic digestion, cogeneration, dewatering and thermal drying. Real site data were preferably included in the inventory. Environmental impacts of the resulting impact categories were determined by the CLM 2 baseline method. According to the results, the combustion of natural gas in the cogeneration engine is responsible for the main impact on Climate Change and Depletion of Abiotic Resources, while the combustion of biogas in the cogeneration unit accounts for a minor part. The results suggest that the environmental performance of the WWTP would be enhanced by increasing biogas production through improved anaerobic digestion of sewage sludge.

  14. Future Energy Benchmark for Desalination: is it Better to have a Power (electricity) Plant with ro or Med/msf?

    Science.gov (United States)

    Shahzad, Muhammad Wakil; Ng, Kim Choon; Thu, Kyaw

    2016-06-01

    Power and desalination cogeneration plants are common in many water scared courtiers. Designers and planners for cogeneration face tough challenges in deciding the options:- Is it better to operate a power plant (PP) with the reverse osmosis (i.e., PP+RO) or the thermally-driven multi-effect distillation/multi-stage flashed (PP+MED/MSF) methods. From literature, the RO methods are known to be energy efficient whilst the MED/MSF are known to have excellent thermodynamic synergies as only low pressure and temperature steam are used. Not with-standing the challenges of severe feed seawater of the Gulf, such as the frequent harmful algae blooms (HABs) and high silt contents, this presentation presents a quantitative analyses using the exergy and energetic approaches in evaluating the performances of a real cogeneration plant that was recently proposed in the eastern part of Saudi Arabia. We demonstrate that the process choice of PP+RO versus PP+MED depends on the inherent efficiencies of individual process method which is closely related to innovative process design. In this connection, a method of primary fuel cost apportionment for a co-generation plant with a MED desalination is presented. We show that an energy approach, that captures the quality of expanding steam, is a better method over the conventional work output (energetic) and the energy method seems to be over-penalizing a thermally-driven MED by as much as 22% in the operating cost of water.

  15. Future Energy Benchmark for Desalination: Is it Better to have a Power (Electricity) Plant With RO or MED/MSF?

    KAUST Repository

    Shahzad, Muhammad Wakil

    2016-06-23

    Power and desalination cogeneration plants are common in many water scared courtiers. Designers and planners for cogeneration face tough challenges in deciding the options:- Is it better to operate a power plant (PP) with the reverse osmosis (i.e., PP+RO) or the thermally-driven multi-effect distillation/multi-stage flashed ( PP+MED/MSF) methods. From literature, the RO methods are known to be energy efficient whilst the MED/MSF are known to have excellent thermodynamic synergies as only low pressure and temperature steam are used. Not with-standing the challenges of severe feed seawater of the Gulf, such as the frequent harmful algae blooms (HABs) and high silt contents, this presentation presents a quantitative analyses using the exergy and energetic approaches in evaluating the performances of a real cogeneration plant that was recently proposed in the eastern part of Saudi Arabia. We demonstrate that the process choice of PP+RO versus PP+MED depends on the inherent efficiencies of individual process method which is closely related to innovative process design. In this connection, a method of primary fuel cost apportionment for a co-generation plant with a MED desalination is presented. We show that an energy approach, that captures the quality of expanding steam, is a better method over the conventional work output (energetic) and the energy method seems to be over-penalizing a thermally-driven MED by as much as 22% in the operating cost of water.

  16. Selection of optimal reheat temperature in heat recovery boiler at combined heat and power plant with GT-topping

    Directory of Open Access Journals (Sweden)

    Romashova Olga

    2017-01-01

    Full Text Available Calculations to determine optimum value of steam reheat temperature in relation to the cycle arrangement of steam turbine power plant with gas turbine topping are conducted in this paper. Operation of T-250-240 turbine unit in cogeneration mode has been considered during steam reheat displacement from steam boiler to heat recovery boiler.

  17. District heating and cooling system for communities through power plant retrofit and distribution network. Final report, Phase I

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    The technical and economic feasibility of retrofitting thermal power plants in Minnesota to accommodate both heat and power generation for district heating was examined and is discussed. Three communities were identified as viable sites for co-generation district heating. (LCL)

  18. Thermodynamic investigation of a shared cogeneration system with electrical cars for northern Europe climate

    DEFF Research Database (Denmark)

    Vialetto, Giulio; Noro, Marco; Rokni, Masoud

    2017-01-01

    Transition to alternative energy systems is indicated by EU Commission as a suitable path to energy efficiency and energy saving in the next years. The aims are to decrease greenhouses gases emissions, relevance of fossil fuels in energy production and energy dependence on extra-EU countries....... These goals can be achieved increasing renewable energy sources and/or efficiency on energy production processes. In this paper an innovative micro-cogeneration system for household application is presented: it covers heating, domestic hot water and electricity demands for a residential user. Solid oxide fuel...... cells, heat pump and Stirling engine are utilised as a system to achieve high energy conversion efficiency. A transition from traditional petrol cars to electric mobility is also considered and simulated here. Different types of fuel are considered to demonstrate the high versatility of the simulated...

  19. A New Cogeneration Residential System Based on Solid Oxide Fuel Cells for a Northern European Climate

    DEFF Research Database (Denmark)

    Vialetto, Giulio; Rokni, Masoud

    2015-01-01

    Energy saving is an open point in most European countries where energy policies are oriented to reduce the use of fossil fuels, greenhouses emissions and energy independence and to increase the use of renewable energies. In the last several years, new technologies have been developed, and some...... of them received subsidies to increase installation and reduce cost. This article presents an innovative cogeneration system based on a solid oxide fuel cell (SOFC) system and heat pump for household applications with a focus on primary energy and economic savings using electric equivalent load parameter...... are performed under different strategies at a resort located in a northern European climate (Denmark) to cover electricity, space heating and domestic hot water (DHW) demands. The results of these simulations are analyzed with thermodynamic and techno-economic benchmarks, considering different economic...

  20. Conceptual engineering of cogeneration and trigeneration systems in applications to the tertiary sector

    International Nuclear Information System (INIS)

    Roque Díaz, Pablo R.; Rubio González, Ángel M.; Rubio Rodríguez, Manuel A.

    2017-01-01

    The present work constitutes a proposal of procedures of conceptual engineering in the studies of preinvestment in systems of combined heating, cooling and power, CHP, CCHP, cogeneration or trigeneration, applied to the tertiary sector. These procedures are regulated in the Decree Law 237/2015, in general form as regulation for investment processes, without dealing with the characteristic issues of this kind of projects, relative to the peculiar fact that in them the feasibility directly depends upon thermodynamic concepts as well as to the precepts of the economy, so it is more rational to apply the Thermoeconomics methods, in particular the theories of the exergy and exergoeconomic costs and the corresponding modeling and optimizing methods for this type of systems. The proposals are illustrated with a real case study which, as a project, is still in the phase of preliminary studies. (author)