WorldWideScience

Sample records for arc delivery radiation

  1. Feasibility of a unified approach to intensity-modulated radiation therapy and volume-modulated arc therapy optimization and delivery

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Douglas A., E-mail: douglas.hoover@lhsc.on.ca; Chen, Jeff Z. [Department of Physics and Engineering, London Regional Cancer Program, London, Ontario N6A 4L6 (Canada); Department of Oncology, Western University, London, Ontario N6A 3K7 (Canada); Department of Medical Biophysics, Western University, London, Ontario N6A 3K7 (Canada); MacFarlane, Michael [Department of Physics and Engineering, London Regional Cancer Program, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, Western University, London, Ontario N6A 3K7 (Canada); Wong, Eugene [Department of Oncology, Western University, London, Ontario N6A 3K7 (Canada); Department of Medical Biophysics, Western University, London, Ontario N6A 3K7 (Canada); Department of Physics and Astronomy, Western University, London, Ontario N6A 3K7 (Canada); Battista, Jerry J. [Department of Physics and Engineering, London Regional Cancer Program, London, Ontario N6A 4L6 (Canada); Department of Oncology, Western University, London, Ontario N6A 3K7 (Canada); Department of Medical Biophysics, Western University, London, Ontario N6A 3K7 (Canada); Department of Physics and Astronomy, Western University, London, Ontario N6A 3K7 (Canada)

    2015-02-15

    Purpose: To study the feasibility of unified intensity-modulated arc therapy (UIMAT) which combines intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) optimization and delivery to produce superior radiation treatment plans, both in terms of dose distribution and efficiency of beam delivery when compared with either VMAT or IMRT alone. Methods: An inverse planning algorithm for UIMAT was prototyped within the PINNACLE treatment planning system (Philips Healthcare). The IMRT and VMAT deliveries are unified within the same arc, with IMRT being delivered at specific gantry angles within the arc. Optimized gantry angles for the IMRT and VMAT phases are assigned automatically by the inverse optimization algorithm. Optimization of the IMRT and VMAT phases is done simultaneously using a direct aperture optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using a unified optimization technique and compared with clinical IMRT or VMAT plans. Delivery verification was performed with an ArcCheck phantom (Sun Nuclear) on a Varian TrueBeam linear accelerator (Varian Medical Systems). Results: In this prototype implementation, the UIMAT plans offered the same target dose coverage while reducing mean doses to organs at risk by 8.4% for head-and-neck cases, 5.7% for lung cases, and 3.5% for prostate cases, compared with the VMAT or IMRT plans. In addition, UIMAT can be delivered with similar efficiency as VMAT. Conclusions: In this proof-of-concept work, a novel radiation therapy optimization and delivery technique that interlaces VMAT or IMRT delivery within the same arc has been demonstrated. Initial results show that unified VMAT/IMRT has the potential to be superior to either standard IMRT or VMAT.

  2. On the tradeoff between treatment time and plan quality in rotational arc radiation delivery

    CERN Document Server

    Craft, David

    2009-01-01

    A new delivery option for cancer centers equipped with linear accelerators fitted with multi-leaf collimators (MLC) -- i.e. centers which can perform intensity modulated radiation therapy (IMRT) -- is rotational delivery. In rotational delivery, the beam is on while the gantry is rotating and the MLC leaves are moving, thus treating the patient more efficiently (regarding time) than in IMRT. A consideration that should be examined when evaluating this new type of delivery method is the tradeoff between treatment plan quality and delivery time: what do we sacrifice in terms of plan quality by guaranteeing a 2 minute delivery, for example? In this paper we examine this question by studying a simplified 2D phantom where leaf and gantry motion are directly included in the optimization model. We formulate the model as a linear mixed integer program. Because of the difficulty in solving to optimality, we employ additional models which allow us to trap the true optimal solution between upper and lower bounds. The lo...

  3. Sci—Fri AM: Mountain — 05: Unified Optimization and Delivery of Intensity-modulated Radiation Therapy and Volume-modulated Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J; Hoover, D [Department of Oncology, Department of Medical Biophysics, London Health Science Centre, London, ON (Canada); MacFarlane, M [London Health Science Centre, London, ON (Canada); Wong, E [Department of Oncology, Department of Medical Biophysics, Department of Physics and Astronomy, University of Western Ontario (Canada)

    2014-08-15

    Purpose: To study the feasibility of a unified intensity-modulated arc therapy (UIMAT) that combines IMRT and VMAT optimization and delivery in order to produce efficient and superior radiation treatment plans. Methods: Inverse planning for UIMAT was prototyped on the Pinnacle treatment planning system (Philips Medical Systems). UIMAT integrates IMRT and VMAT delivery in the same arc where IMRT was delivered with gantry speed close to zero. Optimal gantry angles for the IMRT phases were selected automatically by the inverse optimization algorithm. Optimization of the VMAT phases and IMRT phases were done simultaneously using Pinnacle's direct machine parameter optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using our unified technique and compared with clinical VMAT or IMRT plans. Delivery verification was performed on an ArcCheck phantom (Sun Nuclear) and delivered in clinical mode on a Varian TrueBeam linear accelerator. Results: In this prototype implementation, compared to the VMAT or IMRT plans, with the plans normalized to the same dose coverage to the planning target volumes, the UIMAT plans produced improved OAR sparing for head and neck cases, while for lung and prostate cases, the dosimetric improvements for OARs were not as significant. In this proof-of-concept work, we demonstrated that a novel radiation therapy delivery technique combining VMAT and IMRT delivery in the same arc is feasible. Initial results showed UIMAT has the potential to be superior to either standard IMRT or VMAT.

  4. Target splitting non-coplanar RapidArc radiation therapy for a diffuse sebaceous carcinoma of the scalp: a novel delivery technique

    International Nuclear Information System (INIS)

    To compare conventional lateral photon-electron, fixed-beam intensity modulated radiation therapy (IMRT), coplanar and non-coplanar RapidArc for the treatment of a diffuse sebaceous gland carcinoma of the scalp. Comprehensive dosimetry comparisons were performed among 3D-CRT, IMRT and various RapidArc plans. Target coverage, conformity index (CI), homogeneity index (HI) and doses to organs at risk (OAR) were calculated. Monitor unites (MUs) and delivery time of each treatment were also recorded to evaluate the execution efficiency. The influence of target splitting technique and non-coplanar planning on plan quality was discussed. IMRT was superior to 3D-CRT concerning targets’ coverage at the sacrifice of larger irradiated brain volumes to low doses. CIs and HIs were better in coplanar RapidArc and non-coplanar RapidArc plans than 3D-CRT and IMRT. Best dose coverage and sparing of OARs were achieved in non-coplanar plans using target splitting technique. Treatment delivery time was longest in the IMRT plan and shortest in the coplanar RapidArc plan without target splitting. The 3%/3 mm gamma test pass rates were above 95% for all the plans. Target splitting technique and non-coplanar arcs are recommended for total scalp irradiation

  5. Temporal characterization and in vitro comparison of cell survival following the delivery of 3D-conformal, intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT)

    Science.gov (United States)

    McGarry, Conor K.; Butterworth, Karl T.; Trainor, Colman; O'Sullivan, Joe M.; Prise, Kevin M.; Hounsell, Alan R.

    2011-04-01

    A phantom was designed and implemented for the delivery of treatment plans to cells in vitro. Single beam, 3D-conformal radiotherapy (3D-CRT) plans, inverse planned five-field intensity-modulated radiation therapy (IMRT), nine-field IMRT, single-arc volumetric modulated arc therapy (VMAT) and dual-arc VMAT plans were created on a CT scan of the phantom to deliver 3 Gy to the cell layer and verified using a Farmer chamber, 2D ionization chamber array and gafchromic film. Each plan was delivered to a 2D ionization chamber array to assess the temporal characteristics of the plan including delivery time and 'cell's eye view' for the central ionization chamber. The effective fraction time, defined as the percentage of the fraction time where any dose is delivered to each point examined, was also assessed across 120 ionization chambers. Each plan was delivered to human prostate cancer DU-145 cells and normal primary AGO-1522b fibroblast cells. Uniform beams were delivered to each cell line with the delivery time varying from 0.5 to 20.54 min. Effective fraction time was found to increase with a decreasing number of beams or arcs. For a uniform beam delivery, AGO-1552b cells exhibited a statistically significant trend towards increased survival with increased delivery time. This trend was not repeated when the different modulated clinical delivery methods were used. Less sensitive DU-145 cells did not exhibit a significant trend towards increased survival with increased delivery time for either the uniform or clinical deliveries. These results confirm that dose rate effects are most prevalent in more radiosensitive cells. Cell survival data generated from uniform beam deliveries over a range of dose rates and delivery times may not always be accurate in predicting response to more complex delivery techniques, such as IMRT and VMAT.

  6. Radiation of long and high power arcs

    Science.gov (United States)

    Cressault, Y.; Bauchire, J. M.; Hong, D.; Rabat, H.; Riquel, G.; Sanchez, F.; Gleizes, A.

    2015-10-01

    The operators working on electrical installations of low, medium and high voltages can be accidentally exposed to short-circuit arcs ranging from a few kA to several tens of kA. To protect them from radiation, according to the exposure limits, we need to characterize the radiation emitted by the powerful arc. Therefore, we have developed a general experimental and numerical study in order to estimate the spectral irradiance received at a given distance from the arc. The experimental part was based on a very long arc (up to 2 m) with high ac current (between 4 and 40 kA rms, duration 100 ms) using 3 kinds of metallic contacts (copper, steel and aluminium). We measured the irradiance received 10m from the axis of the arc, and integrated on 4 spectral intervals corresponding to the UV, visible, IRA  +  B and IRC. The theoretical part consisted of calculating the radiance of isothermal plasmas in mixtures of air and metal vapour, integrated over the same spectral intervals as defined in the experiments. The comparison between the theoretical and experimental results has allowed the defining of three isothermal radiation sources whose combination leads to a spectral irradiation equivalent to the experimental one. Then the calculation allowed the deduction of the spectral description of the irradiance over all the wavelength range, between 200 nm and 20 μm. The final results indicate that the influence of metal is important in the visible and UVA ranges whereas the IR radiation is due to the air plasma and surrounding hot gas and fumes.

  7. Effect of arc on radiation thermometry in welding process

    Institute of Scientific and Technical Information of China (English)

    李亮玉; 王燕; 武宝林

    2002-01-01

    The effect of arc on radiation thermometry is analyzed in a field close to the arc during the welding process, and the ratio of signal to noise and other factors are obtained for a small current arc .The method of the temperature measurement is feasible when the arc current is decreased to a smaller value in the welding process.

  8. Exposure assessment of aluminum arc welding radiation.

    Science.gov (United States)

    Peng, Chiung-yu; Lan, Cheng-hang; Juang, Yow-jer; Tsao, Ta-ho; Dai, Yu-tung; Liu, Hung-hsin; Chen, Chiou-jong

    2007-10-01

    The purpose of this study is to evaluate the non-ionizing radiation (NIR) exposure, especially optical radiation levels, and potential health hazard from aluminum arc welding processes based on the American Conference of Governmental Industrial Hygienists (ACGIH) method. The irradiance from the optical radiation emissions can be calculated with various biological effective parameters [i.e., S(lambda), B(lambda), R(lambda)] for NIR hazard assessments. The aluminum arc welding processing scatters bright light with NIR emission including ultraviolet radiation (UVR), visible, and infrared spectra. The UVR effective irradiance (Eeff) has a mean value of 1,100 microW cm at 100 cm distance from the arc spot. The maximum allowance time (tmax) is 2.79 s according to the ACGIH guideline. Blue-light hazard effective irradiance (EBlue) has a mean value of 1840 microW cm (300-700 nm) at 100 cm with a tmax of 5.45 s exposure allowance. Retinal thermal hazard effective calculation shows mean values of 320 mW cm(-2) sr(-1) and 25.4 mW (cm-2) (380-875 nm) for LRetina (spectral radiance) and ERetina (spectral irradiance), respectively. From this study, the NIR measurement from welding optical radiation emissions has been established to evaluate separate types of hazards to the eye and skin simultaneously. The NIR exposure assessment can be applied to other optical emissions from industrial sources. The data from welding assessment strongly suggest employees involved in aluminum welding processing must be fitted with appropriate personal protection devices such as masks and gloves to prevent serious injuries of the skin and eyes upon intense optical exposure.

  9. Tumor cell survival dependence on helical tomotherapy, continuous arc and segmented dose delivery

    Science.gov (United States)

    Yang, Wensha; Wang, Li; Larner, James; Read, Paul; Benedict, Stan; Sheng, Ke

    2009-11-01

    The temporal pattern of radiation delivery has been shown to influence the tumor cell survival fractions for the same radiation dose. To study the effect more specifically for state of the art rotational radiation delivery modalities, 2 Gy of radiation dose was delivered to H460 lung carcinoma, PC3 prostate cancer cells and MCF-7 breast tumor cells by helical tomotherapy (HT), seven-field LINAC (7F), and continuous dose delivery (CDD) over 2 min that simulates volumetric rotational arc therapy. Cell survival was measured by the clonogenic assay. The number of viable H460 cell colonies was 23.2 ± 14.4% and 27.7 ± 15.6% lower when irradiated by CDD compared with HT and 7F, respectively, and the corresponding values were 36.8 ± 18.9% and 35.3 ± 18.9% lower for MCF7 cells (p < 0.01). The survival of PC3 was also lower when irradiated by CDD than by HT or 7F but the difference was not as significant (p = 0.06 and 0.04, respectively). The higher survival fraction from HT delivery was unexpected because 90% of the 2 Gy was delivered in less than 1 min at a significantly higher dose rate than the other two delivery techniques. The results suggest that continuous dose delivery at a constant dose rate results in superior in vitro tumor cell killing compared with prolonged, segmented or variable dose rate delivery.

  10. Tumor cell survival dependence on helical tomotherapy, continuous arc and segmented dose delivery

    Energy Technology Data Exchange (ETDEWEB)

    Yang Wensha; Wang Li; Larner, James; Read, Paul; Benedict, Stan; Sheng Ke [Department of Radiation Oncology, University of Virginia, VA (United States)], E-mail: ks2mc@virginia.edu

    2009-11-07

    The temporal pattern of radiation delivery has been shown to influence the tumor cell survival fractions for the same radiation dose. To study the effect more specifically for state of the art rotational radiation delivery modalities, 2 Gy of radiation dose was delivered to H460 lung carcinoma, PC3 prostate cancer cells and MCF-7 breast tumor cells by helical tomotherapy (HT), seven-field LINAC (7F), and continuous dose delivery (CDD) over 2 min that simulates volumetric rotational arc therapy. Cell survival was measured by the clonogenic assay. The number of viable H460 cell colonies was 23.2 {+-} 14.4% and 27.7 {+-} 15.6% lower when irradiated by CDD compared with HT and 7F, respectively, and the corresponding values were 36.8 {+-} 18.9% and 35.3 {+-} 18.9% lower for MCF7 cells (p < 0.01). The survival of PC3 was also lower when irradiated by CDD than by HT or 7F but the difference was not as significant (p = 0.06 and 0.04, respectively). The higher survival fraction from HT delivery was unexpected because 90% of the 2 Gy was delivered in less than 1 min at a significantly higher dose rate than the other two delivery techniques. The results suggest that continuous dose delivery at a constant dose rate results in superior in vitro tumor cell killing compared with prolonged, segmented or variable dose rate delivery.

  11. Influence of metal vapour on arc temperatures in gas-metal arc welding: convection versus radiation

    Science.gov (United States)

    Murphy, Anthony B.

    2013-06-01

    The presence of metal vapour in gas-metal arc welding has been shown to have two strong effects on the arc plasma: a decrease in temperature throughout the arc, and the formation of a local temperature minimum near the arc axis. These effects have been attributed, on the basis of different computational models, to either the increased radiative emission associated with the presence of metal vapour in the arc plasma, or the influence of the metal vapour influx on convective flow in the arc. This question is investigated using a three-dimensional computational model in which the production and the transport of metal vapour are taken into account self-consistently. Parameters relevant to welding of thin sheets of aluminum are examined. For these conditions, it is found that the first effect (the decrease in temperature throughout the arc) is due to both the increased radiative emission and the influence of the metal vapour influx on flow. The second effect (the local temperature minimum, which in this case occurs just below the wire electrode) is a consequence of the influence of aluminum vapour produced from the wire electrode on flow in the arc. By examining published results and the energy balance in the plasma, it is shown that for welding of steel with higher arc currents, the increased radiative emission can lead to a local temperature minimum at a greater distance from the wire electrode.

  12. Comparison of plan optimization for single and dual volumetric-modulated arc therapy versus intensity-modulated radiation therapy during post-mastectomy regional irradiation

    OpenAIRE

    Zhao, Li-Rong; ZHOU, YI-BING; Sun, Jian-Guo

    2016-01-01

    The aim of the present study was to investigate volumetric-modulated arc therapy (VMAT) with single arc (1ARC) and dual arc (2ARC), and intensity-modulated radiation therapy (IMRT), and to evaluate the quality and delivery efficiency of post-mastectomy regional irradiation. A total of 24 female patients who required post-mastectomy regional irradiation were enrolled into the current study, and 1ARC, 2ARC and IMRT plans were designed for each individual patient. The quality of these plans was ...

  13. Ultraviolet radiation emitted by CO(2) arc welding.

    Science.gov (United States)

    Okuno, T; Ojima, J; Saito, H

    2001-10-01

    The arcs associated with arc welding emit high levels of ultraviolet radiation (UVR), and this often causes acute injuries in the workplace, particularly photokeratoconjunctivitis. It is important to know the level of UVR emitted by arc welding under various conditions, as this information will help in evaluating potential UVR hazards in welding workplaces and taking protective measures against it. In this study, the ACGIH effective irradiance for UVR was measured experimentally for CO(2) arc welding in order to evaluate its UVR hazards. A welding robot was used in the experiment in order to realize reproducible and consistent welding operations. The effective irradiance at 1 m from the arc was in the range 0.28-7.85 W/m(2) (28-785 microW/cm(2)) under the study conditions. The corresponding permissible exposure time per day is only 4-100 s, suggesting that UVR from CO(2) arc welding is actually hazardous for the eye and skin. It was found that the effective irradiance is inversely proportional to the square of the distance from the arc, is strongly dependent on the direction of emission from the arc with a maximum at 50-60 degrees from the plate surface, and tends to increase with welding current.

  14. Feasibility of dose painting using volumetric modulated arc optimization and delivery

    DEFF Research Database (Denmark)

    Korreman, Stine; Ulrich, Silke; Bowen, Stephen;

    2010-01-01

    Dose painting strategies are limited by optimization algorithms in treatment planning systems and physical constraints of the beam delivery. We investigate dose conformity using the RapidArc optimizer and beam delivery technique. Furthermore, robustness of the plans with respect to positioning un...

  15. In-vitro investigation of out-of-field cell survival following the delivery of conformal, intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans

    International Nuclear Information System (INIS)

    The aim of this work is to determine the out-of-field survival of cells irradiated with either the primary field or scattered radiation in the presence and absence of intercellular communication following delivery of conformal, IMRT and VMAT treatment plans. Single beam, conformal, IMRT and VMAT plans were created to deliver 3 Gy to half the area of a T80 flask containing either DU-145 or AGO-1522 cells allowing intercellular communication between the in- and out-of-field cell populations. The same plans were delivered to a similar custom made phantom used to hold two T25 culture flasks, one flask in-field and one out-of-field to allow comparison of cell survival responses when intercellular communication is physically inhibited. Plans were created for the delivery of 8 Gy to the more radio-resistant DU-145 cells only in the presence and absence of intercellular communication. Cell survival was determined by clonogenic assay. In both cell lines, the out-of-field survival was not statistically different between delivery techniques for either cell line or dose. There was however, a statistically significant difference between survival out-of-field when intercellular communication was intact (single T80 culture flask) or inhibited (multiple T25 culture flasks) to in-field for all plans. No statistically significant difference was observed in-field with or without cellular communication to out-of-field for all plans. These data demonstrate out-of-field effects as important determinants of cell survival following exposure to modulated irradiation fields when cellular communication between differentially irradiated cell populations is present. This data is further evidence that refinement of existing radiobiological models to include indirect cell killing effects is required. (paper)

  16. In-vitro investigation of out-of-field cell survival following the delivery of conformal, intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans

    Science.gov (United States)

    McGarry, Conor K.; Butterworth, Karl T.; Trainor, Colman; McMahon, Stephen J.; O'Sullivan, Joe M.; Prise, Kevin M.; Hounsell, Alan R.

    2012-10-01

    The aim of this work is to determine the out-of-field survival of cells irradiated with either the primary field or scattered radiation in the presence and absence of intercellular communication following delivery of conformal, IMRT and VMAT treatment plans. Single beam, conformal, IMRT and VMAT plans were created to deliver 3 Gy to half the area of a T80 flask containing either DU-145 or AGO-1522 cells allowing intercellular communication between the in- and out-of-field cell populations. The same plans were delivered to a similar custom made phantom used to hold two T25 culture flasks, one flask in-field and one out-of-field to allow comparison of cell survival responses when intercellular communication is physically inhibited. Plans were created for the delivery of 8 Gy to the more radio-resistant DU-145 cells only in the presence and absence of intercellular communication. Cell survival was determined by clonogenic assay. In both cell lines, the out-of-field survival was not statistically different between delivery techniques for either cell line or dose. There was however, a statistically significant difference between survival out-of-field when intercellular communication was intact (single T80 culture flask) or inhibited (multiple T25 culture flasks) to in-field for all plans. No statistically significant difference was observed in-field with or without cellular communication to out-of-field for all plans. These data demonstrate out-of-field effects as important determinants of cell survival following exposure to modulated irradiation fields when cellular communication between differentially irradiated cell populations is present. This data is further evidence that refinement of existing radiobiological models to include indirect cell killing effects is required.

  17. Statistical quality control for volumetric modulated arc therapy (VMAT) delivery using machine log data

    CERN Document Server

    Cheong, Kwang-Ho; Kang, Sei-Kwon; Yoon, Jai-Woong; Park, Soah; Hwang, Taejin; Kim, Haeyoung; Kim, Kyoung Ju; Han, Tae Jin; Bae, Hoonsik

    2015-01-01

    The aim of this study is to set up statistical quality control for monitoring of volumetric modulated arc therapy (VMAT) delivery error using machine log data. Eclipse and Clinac iX linac with the RapidArc system (Varian Medical Systems, Palo Alto, USA) is used for delivery of the VMAT plan. During the delivery of the RapidArc fields, the machine determines the delivered motor units (MUs) and gantry angle position accuracy and the standard deviations of MU (sigma_MU; dosimetric error) and gantry angle (sigma_GA; geometric error) are displayed on the console monitor after completion of the RapidArc delivery. In the present study, first, the log data was analyzed to confirm its validity and usability; then, statistical process control (SPC) was applied to monitor the sigma_MU and sigma_GA in a timely manner for all RapidArc fields: a total of 195 arc fields for 99 patients. The sigma_MU and sigma_GA were determined twice for all fields, that is, first during the patient-specific plan QA and then again during th...

  18. Direct leaf trajectory optimization for volumetric modulated arc therapy planning with sliding window delivery

    CERN Document Server

    Papp, Dávid

    2013-01-01

    We propose a novel optimization model for volumetric modulated arc therapy (VMAT) planning that directly optimizes deliverable leaf trajectories in the treatment plan optimization problem, and eliminates the need for a separate arc-sequencing step. In this model, a 360-degree arc is divided into a given number of arc segments in which the leaves move unidirectionally. This facilitates an algorithm that determines the optimal piecewise linear leaf trajectories for each arc segment, which are deliverable in a given treatment time. Multi-leaf collimator (MLC) constraints, including maximum leaf speed and interdigitation, are accounted for explicitly. The algorithm is customized to allow for VMAT delivery using constant gantry speed and dose rate, however, the algorithm generalizes to variable gantry speed if beneficial. We demonstrate the method for three different tumor sites: a head-and-neck case, a prostate case, and a paraspinal case. For that purpose, we first obtain a reference plan for intensity modulated...

  19. Dosimetric verification of RapidArc treatment delivery

    DEFF Research Database (Denmark)

    Korreman, Stine; Medin, Joakim; Kjaer-Kristoffersen, Flemming

    2009-01-01

    . METHODS AND MATERIALS: Nine treatment plans were generated in the Eclipse version 8.5 including the RapidArc optimizer for H&N and prostate cases. The plans were delivered to the Scandidos Delta4 cylindrical diode array phantom. First, the measured dose distributions were compared with the calculated...

  20. Multigroup Approximation of Radiation Transfer in SF6 Arc Plasmas

    Directory of Open Access Journals (Sweden)

    Milada Bartlova

    2013-01-01

    Full Text Available The first order of the method of spherical harmonics (P1-approximation has been used to evaluate the radiation properties of arc plasmas of various mixtures of SF6 and PTFE ((C2F4n, polytetrafluoroethylene in the temperature range (1000 ÷ 35 000 K and pressures from 0.5 to 5 MPa. Calculations have been performed for isothermal cylindrical plasma of various radii (0.01 ÷ 10 cm. The frequency dependence of the absorption coefficients has been handled using the Planck and Rosseland averaging methods for several frequency intervals. Results obtained using various means calculated for different choices of frequency intervals are discussed.

  1. SU-E-T-187: Feasibility Study of Stereotactic Liver Radiation Therapy Using Multiple Divided Partial Arcs in Volumetric Modulated Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Y; Ozawa, S; Tsegmed, U; Nakashima, T; Shintaro, T; Ochi, Y; Kawahara, D; Kimura, T; Nagata, Y [Hiroshima University, Hiroshima, Hiroshima (Japan)

    2014-06-01

    Purpose: To verify volumetric modulated arc therapy (VMAT) using flattening filter free (FFF) mode with jaw tracking (JT) feature for single breath hold as long as 15 s per arc in liver stereotactic body radiation therapy (SBRT) against intensity modulated radiation therapy (IMRT) FFF-JT. Methods: Ten hepatocellular carcinoma (HCC) cases were planned with 10 MV FFF using Pinnacle3 treatment planning system which delivered by TrueBeam to administer 48 Gy/ 4 fractions. Eight non-coplanar beams were assigned to IMRT using step-and-shoot technique. For VMAT, two or three non-coplanar partial arcs (up to 180 degrees) were further divided into subarcs with gantry rotation less than 80 degrees to limit delivery time within 15 s. Dose distributions were verified using OCTAVIUS II system and pass rates were evaluated using gamma analysis with criteria of 3%/3 mm at threshold of 5% to the maximum dose. The actual irradiation time was measured. Results: The VMAT-FFF-JT of partial-arcs with sub-divided arcs was able to produce a highly conformal plan as well as IMRT-FFF-JT. Isodose lines and DVH showed slight improvement in dosimetry when JT was employed for both IMRT and VMAT. Consequently, VMAT-FFF-JT was superior in reducing the dose to liver minus gross tumor volume. VMAT-FFF-JT has shorter total treatment time compared with 3D conformal radiation therapy (3D-CRT) FFF because the gantry was rotated simultaneously with the beam delivery in VMAT. Moreover, due to the small and regular shape of HCC, VMAT-FFF-JT offered less multileaf collimator motion, thus the interplay effect is expected to be reduced. The patient specific QA of IMRT and VMAT acquired the pass rates higher than 90%. Conclusion: VMAT-FFF-JT could be a promising technique for liver SBRT as the sub-divided arcs method was able to accommodate a single breath hold irradiation time of less than 15 s without deterioration of the dose distribution compared with IMRT-FFF-JT.

  2. Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer : a planning study

    NARCIS (Netherlands)

    Holt, Andrea; Van Gestel, Dirk; Arends, Mark P.; Korevaar, Erik W.; Schuring, Danny; Kunze-Busch, Martina C.; Louwe, Rob J. W.; van Vliet-Vroegindeweij, Corine

    2013-01-01

    Background: Compared to static beam Intensity-Modulated Radiation Therapy (IMRT), the main advantage of Volumetric Modulated Arc Therapy (VMAT) is a shortened delivery time, which leads to improved patient comfort and possibly smaller intra-fraction movements. This study aims at a treatment planner-

  3. Dose calculation for hypofractionated volumetric-modulated arc therapy: approximating continuous arc delivery and tongue-and-groove modeling.

    Science.gov (United States)

    Yang, Jie; Tang, Grace; Zhang, Pengpeng; Hunt, Margie; Lim, Seng B; LoSasso, Thomas; Mageras, Gig

    2016-01-01

     Hypofractionated treatments generally increase the complexity of a treatment plan due to the more stringent constraints of normal tissues and target coverage. As a result, treatment plans contain more modulated MLC motions that may require extra efforts for accurate dose calculation. This study explores methods to minimize the differences between in-house dose calculation and actual delivery of hypofractionated volumetric-modulated arc therapy (VMAT), by focusing on arc approximation and tongue-and-groove (TG) modeling. For dose calculation, the continuous delivery arc is typically approximated by a series of static beams with an angular spacing of 2°. This causes significant error when there is large MLC movement from one beam to the next. While increasing the number of beams will minimize the dose error, calculation time will increase significantly. We propose a solution by inserting two additional apertures at each of the beam angle for dose calculation. These additional apertures were interpolated at two-thirds' degree before and after each beam. Effectively, there were a total of three MLC apertures at each beam angle, and the weighted average fluence from the three apertures was used for calculation. Because the number of beams was kept the same, calculation time was only increased by about 6%-8%. For a lung plan, areas of high local dose differences (> 4%) between film measurement and calculation with one aperture were significantly reduced in calculation with three apertures. Ion chamber measure-ment also showed similar results, where improvements were seen with calculations using additional apertures. Dose calculation accuracy was further improved for TG modeling by developing a sampling method for beam fluence matrix. Single ele-ment point sampling for fluence transmitted through MLC was used for our fluence matrix with 1 mm resolution. For Varian HDMLC, grid alignment can cause fluence sampling error. To correct this, transmission volume averaging was

  4. Artificial Optical Radiation photobiological hazards in arc welding.

    Science.gov (United States)

    Gourzoulidis, G A; Achtipis, A; Topalis, F V; Kazasidis, M E; Pantelis, D; Markoulis, A; Kappas, C; Bourousis, C A

    2016-08-01

    Occupational Health and Safety (OHS) is associated with crucial social, economic, cultural and technical issues. A highly specialized OHS sector deals with the photobiological hazards from artificial optical radiation (AOR), which is divided into visible light, UV and IR emitted during various activities and which is legally covered by European Directive 2006/25/EC. Among the enormous amount of sources emitting AOR, the most important non-coherent ones to consider for health effects to the whole optical range, are arcs created during metal welding. This survey presents the effort to assess the complicated exposure limits of the Directive in the controlled environment of a welding laboratory. Sensors covering the UV and blue light range were set to measure typical welding procedures reproduced in the laboratory. Initial results, apart from apparently justifying the use of Personal Protective Equipment (PPE) due to even subsecond overexposures measured, also set the basis to evaluate PPE's properties and support an integrated risk assessment of the complex welding environment. These results can also improve workers' and employer's information and training about radiation hazards, which is a crucial OHS demand.

  5. Artificial Optical Radiation photobiological hazards in arc welding.

    Science.gov (United States)

    Gourzoulidis, G A; Achtipis, A; Topalis, F V; Kazasidis, M E; Pantelis, D; Markoulis, A; Kappas, C; Bourousis, C A

    2016-08-01

    Occupational Health and Safety (OHS) is associated with crucial social, economic, cultural and technical issues. A highly specialized OHS sector deals with the photobiological hazards from artificial optical radiation (AOR), which is divided into visible light, UV and IR emitted during various activities and which is legally covered by European Directive 2006/25/EC. Among the enormous amount of sources emitting AOR, the most important non-coherent ones to consider for health effects to the whole optical range, are arcs created during metal welding. This survey presents the effort to assess the complicated exposure limits of the Directive in the controlled environment of a welding laboratory. Sensors covering the UV and blue light range were set to measure typical welding procedures reproduced in the laboratory. Initial results, apart from apparently justifying the use of Personal Protective Equipment (PPE) due to even subsecond overexposures measured, also set the basis to evaluate PPE's properties and support an integrated risk assessment of the complex welding environment. These results can also improve workers' and employer's information and training about radiation hazards, which is a crucial OHS demand. PMID:27422373

  6. Natural gamma-radiation in the Aeolian volcanic arc

    Energy Technology Data Exchange (ETDEWEB)

    Chiozzi, P.; Pasquale, V. E-mail: pasquale@dipteris.unige.it; Verdoya, M.; Minato, S

    2001-11-01

    Pulse-height distributions of {gamma}-rays, obtained with a field NaI(Tl) scintillation spectrometer in numerous sites of the Lipari and Vulcano islands (Aeolian volcanic arc, Italy), were measured to determine the U, Th and K concentrations of the bedrock and the relative values of the air absorbed dose rate. U is spatially related to both Th and K and the Th/U ratio is on average 3.1-3.5. The magmatic evolution is reflected by the concentration of the three radioelements, as they are more abundant within the more felsic units of the volcanic series. The higher values of U (15.7-20.0 ppm) coincide with higher Th (48.3-65.9 ppm) and K (4.9-6.1%) concentrations associated with rhyolitic rocks of the third cycle (<50 ky). The air absorbed dose rate varies from 20 to 470 nGy h{sup -1}. The highest values (>350 nGy h{sup -1}) are observed on outcrops of rhyolitic obsidian lava flows. The cosmic-ray contribution is also evaluated to estimate the total background radiation dose rate.

  7. Natural gamma-radiation in the Aeolian volcanic arc.

    Science.gov (United States)

    Chiozzi, P; Pasquale, V; Verdoya, M; Minato, S

    2001-11-01

    Pulse-height distributions of gamma-rays, obtained with a field NaI(Tl) scintillation spectrometer in numerous sites of the Lipari and Vulcano islands (Aeolian volcanic arc, Italy), were measured to determine the U, Th and K concentrations of the bedrock and the relative values of the air absorbed dose rate. U is spatially related to both Th and K and the Th/U ratio is on average 3.1-3.5. The magmatic evolution is reflected by the concentration of the three radioelements, as they are more abundant within the more felsic units of the volcanic series. The higher values of U (15.7-20.0 ppm) coincide with higher Th (48.3-65.9 ppm) and K (4.9-6.1%) concentrations associated with rhyolitic rocks of the third cycle ( 350 nGy h(-1)) are observed on outcrops of rhyolitic obsidian lava flows. The cosmic-ray contribution is also evaluated to estimate the total background radiation dose rate. PMID:11573810

  8. A Theoretical Model of Arc Light Radiation Based on GTA Spectral Diagnosis

    Institute of Scientific and Technical Information of China (English)

    Chenming XU; Hongming GAO; Guangjun ZHANG; Lin WU

    2003-01-01

    An arc light radiation phenomenon in TIG welding process was studied through experiments and theoretical analysis.The arc spectra were acquired under a variety of welding parameters from 200 nm to 1000 nm wavelength rangein TIG. The influence of welding p

  9. The role of radiation losses in high-pressure blasted electrical arcs

    International Nuclear Information System (INIS)

    The paper deals with experiments carried out on an arc heater where the electric arc is stabilised by flowing working gas. Measured quantities (especially arc current, voltage drop, gas flow rate, and energy loss) serve as input data for a mathematical model of the arc inside a cylindrical anode channel. Previously, the losses of cathode and anode spots were assumed to be negligible in comparison with the total loss. In the new sets of experiments, a modular structure of the arc heater has made it possible to separate the losses of anode and cathode from the energy losses of the arc itself. Furthermore, the losses caused by radial conduction have been introduced into the model. The most significant change of the model concerns the computation of radiation losses of the arc. In the original model, radiation losses were taken as a portion ε of the total input power. In the modified model, the radiation loss is expressed using a theoretically calculated net emission coefficient of argon (by V. Aubrecht and M. Bartlova). This approach is possible due to a more precise determination of the arc net energy loss which results in flatter radial temperature profiles. Axial distribution of energy loss for the original and modified model is given in figures.

  10. Development of a novel ArcCHECK{sup Trade-Mark-Sign} insert for routine quality assurance of VMAT delivery including dose calculation with inhomogeneities

    Energy Technology Data Exchange (ETDEWEB)

    Fakir, H.; Gaede, S.; Mulligan, M.; Chen, J. Z. [Department of Physics, London Regional Cancer Program, London, Ontario N6A 4L6 (Canada)

    2012-07-15

    Purpose: To design a versatile, nonhomogeneous insert for the dose verification phantom ArcCHECK{sup Trade-Mark-Sign} (Sun Nuclear Corp., FL) and to demonstrate its usefulness for the verification of dose distributions in inhomogeneous media. As an example, we demonstrate it can be used clinically for routine quality assurance of two volumetric modulated arc therapy (VMAT) systems for lung stereotactic body radiation therapy (SBRT): SmartArc{sup Registered-Sign} (Pinnacle{sup 3}, Philips Radiation Oncology Systems, Fitchburg, WI) and RapidArc{sup Registered-Sign} (Eclipse{sup Trade-Mark-Sign }, Varian Medical Systems, Palo Alto, CA). Methods: The cylindrical detector array ArcCHECK{sup Trade-Mark-Sign} has a retractable homogeneous acrylic insert. In this work, we designed and manufactured a customized heterogeneous insert with densities that simulate soft tissue, lung, bone, and air. The insert offers several possible heterogeneity configurations and multiple locations for point dose measurements. SmartArc{sup Registered-Sign} and RapidArc{sup Registered-Sign} plans for lung SBRT were generated and copied to ArcCHECK{sup Trade-Mark-Sign} for each inhomogeneity configuration. Dose delivery was done on a Varian 2100 ix linac. The evaluation of dose distributions was based on gamma analysis of the diode measurements and point doses measurements at different positions near the inhomogeneities. Results: The insert was successfully manufactured and tested with different measurements of VMAT plans. Dose distributions measured with the homogeneous insert showed gamma passing rates similar to our clinical results ({approx}99%) for both treatment-planning systems. Using nonhomogeneous inserts decreased the passing rates by up to 3.6% in the examples studied. Overall, SmartArc{sup Registered-Sign} plans showed better gamma passing rates for nonhomogeneous measurements. The discrepancy between calculated and measured point doses was increased up to 6.5% for the nonhomogeneous

  11. Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ashamalla, Hani; Tejwani, Ajay; Parameritis, Loannis; Swamy, Uma; Luo, Pei Ching; Guirguis, Adel; Lavaf, Amir [Weill Medical College of Cornell University, Brooklyn, NY (United States)

    2013-06-15

    Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Sixteen patients were studied. Prostate (PTV{sub P}), right pelvic (PTV{sub RtLN}) and left pelvic lymph nodes (PTV{sub LtLN}), and organs at risk were contoured. PTVP, PTV{sub RtLN}, and PTV{sub LtLN} received 50.40 Gy followed by a boost to PTV{sub B} of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose (D{sub MEAN}) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The D{sub MEAN} of bladder was within 2% of each other. The rectum D{sub MEAN} in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.

  12. Volumetric Modulated Arc Therapy for Spine Radiosurgery: Superior Treatment Planning and Delivery Compared to Static Beam Intensity Modulated Radiotherapy

    Directory of Open Access Journals (Sweden)

    Leor Zach

    2016-01-01

    Full Text Available Purpose. Spine stereotactic radiosurgery (SRS delivers an accurate and efficient high radiation dose to vertebral metastases in 1–5 fractions. We aimed to compare volumetric modulated arc therapy (VMAT to static beam intensity modulated radiotherapy (IMRT for spine SRS. Methods and Materials. Ten spine lesions of previously treated SRS patients were planned retrospectively using both IMRT and VMAT with a prescribed dose of 16 Gy to 100% of the planning target volume (PTV. The plans were compared for conformity, homogeneity, treatment delivery time, and safety (spinal cord dose. Results. All evaluated parameters favored the VMAT plan over the IMRT plans. Dmin in the IMRT was significantly lower than in the VMAT plan (7.65 Gy/10.88 Gy, p<0.001, the Dice Similarity Coefficient (DSC was found to be significantly better for the VMAT plans compared to the IMRT plans (0.77/0.58, resp., p  value<0.01, and an almost 50% reduction in the net treatment time was calculated for the VMAT compared to the IMRT plans (6.73 min/12.96 min, p<0.001. Conclusions. In our report, VMAT provides better conformity, homogeneity, and safety profile. The shorter treatment time is a major advantage and not only provides convenience to the painful patient but also contributes to the precision of this high dose radiation therapy.

  13. Plan comparison of volumetric-modulated arc therapy (RapidArc and conventional intensity-modulated radiation therapy (IMRT in anal canal cancer

    Directory of Open Access Journals (Sweden)

    Aillères Norbert

    2010-10-01

    Full Text Available Abstract Background To compare volumetric-modulated arc therapy (RapidArc plans with conventional intensity-modulated radiation therapy (IMRT plans in anal canal cancers. Methods Ten patients with anal canal carcinoma previously treated with IMRT in our institution were selected for this study. For each patient, three plans were generated with the planning CT scan: one using a fixed beam IMRT, and two plans using the RapidArc technique: a single (RA1 and a double (RA2 modulated arc therapy. The treatment plan was designed to deliver in one process with simultaneous integrated boost (SIB a dose of 59.4 Gy to the planning target volume (PTV2 based on the gross disease in a 1.8 Gy-daily fraction, 5 days a week. At the same time, the subclinical disease (PTV1 was planned to receive 49.5 Gy in a 1.5 Gy-daily fraction. Plans were normalized to 99% of the PTV2 that received 95% of the prescribed dose. Planning objectives were 95% of the PTV1 will receive 95% of the prescribed dose and no more than 2% of the PTV will receive more than 107%. Dose-volume histograms (DVH for the target volume and the organs at risk (bowel tract, bladder, iliac crests, femoral heads, genitalia/perineum, and healthy tissue were compared for these different techniques. Monitor units (MU and delivery treatment time were also reported. Results All plans achieved fulfilled objectives. Both IMRT and RA2 resulted in superior coverage of PTV than RA1 that was slightly inferior for conformity and homogeneity (p Conformity index (CI95% for the PTV2 was 1.15 ± 0.15 (RA2, 1.28 ± 0.22 (IMRT, and 1.79 ± 0.5 (RA1. Homogeneity (D5% - D95% for PTV2 was 3.21 ± 1.16 Gy (RA2, 2.98 ± 0.7 Gy (IMRT, and 4.3 ± 1.3 Gy (RA1. RapidArc showed to be superior to IMRT in terms of organ at risk sparing. For bowel tract, the mean dose was reduced of 4 Gy by RA2 compared to IMRT. Similar trends were observed for bladder, femoral heads, and genitalia. The DVH of iliac crests and healthy tissue resulted

  14. Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer

    International Nuclear Information System (INIS)

    To compare volumetric-modulated arc therapy (RapidArc) plans with conventional intensity-modulated radiation therapy (IMRT) plans in anal canal cancers. Ten patients with anal canal carcinoma previously treated with IMRT in our institution were selected for this study. For each patient, three plans were generated with the planning CT scan: one using a fixed beam IMRT, and two plans using the RapidArc technique: a single (RA1) and a double (RA2) modulated arc therapy. The treatment plan was designed to deliver in one process with simultaneous integrated boost (SIB) a dose of 59.4 Gy to the planning target volume (PTV2) based on the gross disease in a 1.8 Gy-daily fraction, 5 days a week. At the same time, the subclinical disease (PTV1) was planned to receive 49.5 Gy in a 1.5 Gy-daily fraction. Plans were normalized to 99% of the PTV2 that received 95% of the prescribed dose. Planning objectives were 95% of the PTV1 will receive 95% of the prescribed dose and no more than 2% of the PTV will receive more than 107%. Dose-volume histograms (DVH) for the target volume and the organs at risk (bowel tract, bladder, iliac crests, femoral heads, genitalia/perineum, and healthy tissue) were compared for these different techniques. Monitor units (MU) and delivery treatment time were also reported. All plans achieved fulfilled objectives. Both IMRT and RA2 resulted in superior coverage of PTV than RA1 that was slightly inferior for conformity and homogeneity (p < 0.05). Conformity index (CI95%) for the PTV2 was 1.15 ± 0.15 (RA2), 1.28 ± 0.22 (IMRT), and 1.79 ± 0.5 (RA1). Homogeneity (D5% - D95%) for PTV2 was 3.21 ± 1.16 Gy (RA2), 2.98 ± 0.7 Gy (IMRT), and 4.3 ± 1.3 Gy (RA1). RapidArc showed to be superior to IMRT in terms of organ at risk sparing. For bowel tract, the mean dose was reduced of 4 Gy by RA2 compared to IMRT. Similar trends were observed for bladder, femoral heads, and genitalia. The DVH of iliac crests and healthy tissue resulted in comparable sparing for

  15. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

    Energy Technology Data Exchange (ETDEWEB)

    Mail, Noor; Al-Ghamdi, S.; Saoudi, A. [Princess Norah Oncology Center, National Guard Health Affairs, Jeddah 21423, Saudi Arabia and King Abdullah International Medical Research Center, Jeddah 21423 (Saudi Arabia); Albarakati, Y.; Ahmad Khan, M.; Saeedi, F.; Safadi, N. [Princess Norah Oncology Center, National Guard Health Affairs, Jeddah 21423 (Saudi Arabia)

    2013-08-15

    Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined

  16. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

    International Nuclear Information System (INIS)

    Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined

  17. Proton Arc Reduces Range Uncertainty Effects and Improves Conformality Compared With Photon Volumetric Modulated Arc Therapy in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Seco, Joao, E-mail: jseco@partners.org [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Gu, Guan; Marcelos, Tiago; Kooy, Hanne; Willers, Henning [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2013-09-01

    Purpose: To describe, in a setting of non-small cell lung cancer (NSCLC), the theoretical dosimetric advantages of proton arc stereotactic body radiation therapy (SBRT) in which the beam penumbra of a rotating beam is used to reduce the impact of range uncertainties. Methods and Materials: Thirteen patients with early-stage NSCLC treated with proton SBRT underwent repeat planning with photon volumetric modulated arc therapy (Photon-VMAT) and an in-house-developed arc planning approach for both proton passive scattering (Passive-Arc) and intensity modulated proton therapy (IMPT-Arc). An arc was mimicked with a series of beams placed at 10° increments. Tumor and organ at risk doses were compared in the context of high- and low-dose regions, represented by volumes receiving >50% and <50% of the prescription dose, respectively. Results: In the high-dose region, conformality index values are 2.56, 1.91, 1.31, and 1.74, and homogeneity index values are 1.29, 1.22, 1.52, and 1.18, respectively, for 3 proton passive scattered beams, Passive-Arc, IMPT-Arc, and Photon-VMAT. Therefore, proton arc leads to a 30% reduction in the 95% isodose line volume to 3-beam proton plan, sparing surrounding organs, such as lung and chest wall. For chest wall, V30 is reduced from 21 cm{sup 3} (3 proton beams) to 11.5 cm{sup 3}, 12.9 cm{sup 3}, and 8.63 cm{sup 3} (P=.005) for Passive-Arc, IMPT-Arc, and Photon-VMAT, respectively. In the low-dose region, the mean lung dose and V20 of the ipsilateral lung are 5.01 Gy(relative biological effectiveness [RBE]), 4.38 Gy(RBE), 4.91 Gy(RBE), and 5.99 Gy(RBE) and 9.5%, 7.5%, 9.0%, and 10.0%, respectively, for 3-beam, Passive-Arc, IMPT-Arc, and Photon-VMAT, respectively. Conclusions: Stereotactic body radiation therapy with proton arc and Photon-VMAT generate significantly more conformal high-dose volumes than standard proton SBRT, without loss of coverage of the tumor and with significant sparing of nearby organs, such as chest wall. In addition

  18. Volumetric modulated arc therapy for lung stereotactic radiation therapy can achieve high local control rates

    International Nuclear Information System (INIS)

    The aim of this study was to report the outcome of primary or metastatic lung cancer patients undergoing volumetric modulated arc therapy for stereotactic body radiation therapy (VMAT-SBRT). From October 2010 to December 2013, consecutive 67 lung cancer patients received single-arc VMAT-SBRT using an Elekta-synergy system. All patients were treated with an abdominal compressor. The gross tumor volumes were contoured on 10 respiratory phases computed tomography (CT) datasets from 4-dimensional (4D) CT and merged into internal target volumes (ITVs). The planning target volume (PTV) margin was isotropically taken as 5 mm. Treatment was performed with a D95 prescription of 50 Gy (43 cases) or 55 Gy (12 cases) in 4 fractions for peripheral tumor or 56 Gy in 7 fractions (12 cases) for central tumor. Among the 67 patients, the median age was 73 years (range, 59–95 years). Of the patients, male was 72% and female 28%. The median Karnofsky performance status was 90-100% in 39 cases (58%) and 80-90% in 20 cases (30%). The median follow-up was 267 days (range, 40–1162 days). Tissue diagnosis was performed in 41 patients (61%). There were T1 primary lung tumor in 42 patients (T1a in 28 patients, T1b in 14 patients), T2 in 6 patients, three T3 in 3 patients, and metastatic lung tumor in 16 patients. The median mean lung dose was 6.87 Gy (range, 2.5-15 Gy). Six patients (9%) developed radiation pneumonitis required by steroid administration. Actuarial local control rate were 100% and 100% at 1 year, 92% and 75% at 2 years, and 92% and 75% at 3 years in primary and metastatic lung cancer, respectively (p = 0.59). Overall survival rate was 83% and 84% at 1 year, 76% and 53% at 2 years, and 46% and 20% at 3 years in primary and metastatic lung cancer, respectively (p = 0.12). Use of VMAT-based delivery of SBRT in primary in metastatic lung tumors demonstrates high local control rates and low risk of normal tissue complications

  19. A Two-Flux Radiation Model for Helical Instability of Arcs

    Institute of Scientific and Technical Information of China (English)

    GONG Ye; ZHENG Shu; XU Xiang; ZOU Xiu; LIU Jin-Yuan; LIU Yue; WANG Xiao-Gang

    2005-01-01

    @@ A two-flux radiation model of the helical instability of arcs in axial magnetic field is presented. The temperature (and electrical conductivity) is approximated in a more realistic way (parabolic instead of flat profile) and a simplified term of radiation losses is included in the energy equation. The magnetohydrodynamic equations in an electrostatic approximation serve as the starting point of the theory. Using a linear time-dependent perturbation theory, the corresponding equations and an explicit analytic expression that corresponds to the term of radiation losses are derived in the presence of the radiation transfer energy, from which the marginal Maecker number and the growth rate of the helical instability can be given. It is found that, in comparison with the results without radiation, the arc stable area is reduced.

  20. Robotic Delivery of Complex Radiation Volumes for Small Animal Research.

    Science.gov (United States)

    Matinfar, Mohammad; Iordachita, Iulian; Wong, John; Kazanzides, Peter

    2010-07-15

    The Small Animal Radiation Research Platform (SARRP) is a novel and complete system capable of delivering multidirectional (focal), kilo-voltage radiation fields to targets in small animals under robotic control using cone-beam CT (CBCT) image guidance. The capability of the SARRP to deliver highly focused beams to multiple animal models provides new research opportunities that more realistically bridge laboratory research and clinical translation. This paper describes the design and operation of the SARRP for precise radiation delivery. Different delivery procedures are presented which enable the system to radiate through a series of points, representative of a complex shape. A particularly interesting case is shell dose irradiation, where the goal is to deliver a high dose of radiation to the shape surface, with minimal dose to the shape interior. The ability to deliver a dose shell allows mechanistic research of how a tumor interacts with its microenvironment to sustain its growth and lead to its resistance or recurrence.

  1. Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results

    International Nuclear Information System (INIS)

    Purpose. To report early clinical experience in stereotactic body radiation therapy (SBRT) delivered using volumetric intensity modulated arc therapy with RapidArc (RA) in patients with primary or metastatic tumours at abdominal sites. Material and methods. Thirty-seven consecutive patients were treated using RA. Of these, 16 had primary or metastatic liver tumours, nine had pancreatic cancer and 12 a nodal metastasis in the retro-peritoneum. Dose prescription varied from 45 to 75 Gy to the Clinical Target Volume in 3 to 6 fractions. The median follow-up was 12 months (6-22). Early local control and toxicity were investigated and reported. Results. Planning objectives on target volumes and organs at risk were met in most cases. Delivery time ranged from 2.8 ± 0.3 to 9.2 ± 2.4 minutes and pre-treatment plan verification resulted in a Gamma Agreement Index from 95.3 ± 3.8 to 98.3 ± 1.7%. At the time of analysis, local control (freedom from progression) at six months, was assessable in 24 of 37 patients and was achieved in 19 patients with a crude rate of 79.2%. Seven patients experienced treatment-related toxicity. Three patients experienced a mild and transient G1 enteritis and two showed a transient G1 liver damage. Two had late toxicity: one developed chronic enteritis causing G1 diarrhoea and G1 abdominal pain and one suffered at three months a G3 gastric bleeding. No patients experienced G4 acute toxicity. Conclusions. SBRT for abdominal targets delivered by means of RA resulted to be feasible with good early clinical results in terms of local control rate and acute toxicity profile. RA allowed to achieve required target coverage as well as to keep within normal tissue dose/volume constraints

  2. Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Scorsetti, Marta; Bignardi, Mario; Alongi, Filippo; Mancosu, Pietro; Navarria, Piera; Castiglioni, Simona; Pentimalli, Sara; Tozzi, Angelo (IRCCS Istituto Clinico Humanitas, Rozzano (Italy)), e-mail: pietro.mancosu@humanitas.it; Fogliata, Antonella; Cozzi, Luca (Oncology Inst. of Southern Switzerland, Bellinzona (Switzerland))

    2011-05-15

    Purpose. To report early clinical experience in stereotactic body radiation therapy (SBRT) delivered using volumetric intensity modulated arc therapy with RapidArc (RA) in patients with primary or metastatic tumours at abdominal sites. Material and methods. Thirty-seven consecutive patients were treated using RA. Of these, 16 had primary or metastatic liver tumours, nine had pancreatic cancer and 12 a nodal metastasis in the retro-peritoneum. Dose prescription varied from 45 to 75 Gy to the Clinical Target Volume in 3 to 6 fractions. The median follow-up was 12 months (6-22). Early local control and toxicity were investigated and reported. Results. Planning objectives on target volumes and organs at risk were met in most cases. Delivery time ranged from 2.8 +- 0.3 to 9.2 +- 2.4 minutes and pre-treatment plan verification resulted in a Gamma Agreement Index from 95.3 +- 3.8 to 98.3 +- 1.7%. At the time of analysis, local control (freedom from progression) at six months, was assessable in 24 of 37 patients and was achieved in 19 patients with a crude rate of 79.2%. Seven patients experienced treatment-related toxicity. Three patients experienced a mild and transient G1 enteritis and two showed a transient G1 liver damage. Two had late toxicity: one developed chronic enteritis causing G1 diarrhoea and G1 abdominal pain and one suffered at three months a G3 gastric bleeding. No patients experienced G4 acute toxicity. Conclusions. SBRT for abdominal targets delivered by means of RA resulted to be feasible with good early clinical results in terms of local control rate and acute toxicity profile. RA allowed to achieve required target coverage as well as to keep within normal tissue dose/volume constraints

  3. Intelligent drug delivery systems obtained by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Martellini, Flavia; Higa, Olga Z.; Takacs, Erzsebet; Safranj, Agneza; Yoshida, Masaru; Katakai, Ryoichi; Carenza, Mario

    1998-06-01

    Radiation-induced polymerization of acryloyl-L-proline methyl ester, an {alpha}-aminoacid-containing monomer, in the presence of a crosslinking agent and a hydrophilic monomer gave rise to polymer hydrogels whose water content at equilibrium was found to decrease as the swelling temperature increased. Some hydrogel samples were obtained with entrapped acetaminophen, an analgesic and antipyretic drug. It was ascertained that the release of the drug was controlled by both the hydrophilicity of the polymer matrices and the environmental temperature.

  4. Intelligent drug delivery systems obtained by radiation

    Science.gov (United States)

    Martellini, Flavia; Higa, Olga Z.; Takacs, Erzsebet; Safranj, Agneza; Yoshida, Masaru; Katakai, Ryoichi; Carenza, Mario

    1998-06-01

    Radiation-induced polymerization of acryloyl-L-proline methyl ester, an α-aminoacid-containing monomer, in the presence of a crosslinking agent and a hydrophilic monomer gave rise to polymer hydrogels whose water content at equilibrium was found to decrease as the swelling temperature increased. Some hydrogel samples were obtained with entrapped acetaminophen, an analgesic and antipyretic drug. It was ascertained that the release of the drug was controlled by both the hydrophilicity of the polymer matrices and the environmental temperature.

  5. Order Reduction of the Radiative Heat Transfer Model for the Simulation of Plasma Arcs

    CERN Document Server

    Fagiano, Lorenzo

    2015-01-01

    An approach to derive low-complexity models describing thermal radiation for the sake of simulating the behavior of electric arcs in switchgear systems is presented. The idea is to approximate the (high dimensional) full-order equations, modeling the propagation of the radiated intensity in space, with a model of much lower dimension, whose parameters are identified by means of nonlinear system identification techniques. The low-order model preserves the main structural aspects of the full-order one, and its parameters can be straightforwardly used in arc simulation tools based on computational fluid dynamics. In particular, the model parameters can be used together with the common approaches to resolve radiation in magnetohydrodynamic simulations, including the discrete-ordinate method, the P-N methods and photohydrodynamics. The proposed order reduction approach is able to systematically compute the partitioning of the electromagnetic spectrum in frequency bands, and the related absorption coefficients, tha...

  6. Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer.

    Science.gov (United States)

    Lin, Jia-Fu; Yeh, Dah-Cherng; Yeh, Hui-Ling; Chang, Chen-Fa; Lin, Jin-Ching

    2015-01-01

    To compare the dosimetric performance of 3 different treatment techniques: hybrid volumetric-modulated arc therapy (hybrid-VMAT), pure-VMAT, and fixed-field intensity-modulated radiation therapy (F-IMRT) for whole-breast irradiation of left-sided early breast cancer. The hybrid-VMAT treatment technique and 2 other treatment techniques—pure-VMAT and F-IMRT—were compared retrospectively in 10 patients with left-sided early breast cancer. The treatment plans of these patients were replanned using the same contours based on the original computed tomography (CT) data sets. Dosimetric parameters were calculated to evaluate plan quality. Total monitor units (MUs) and delivery time were also recorded and evaluated. The hybrid-VMAT plan generated the best results in dose coverage of the target and the dose uniformity inside the target (p lung irradiated to doses of 20 Gy (V(20 Gy)) and 5 Gy (V(5 Gy)) by the hybrid-VMAT plan were significantly less than those of the F-IMRT and the pure-VMAT plans. The volume of ipsilateral lung irradiated to a dose of 5 Gy was significantly less using the hybrid-VMAT plan than that using the F-IMRT or the pure-VMAT plan. The total mean MUs for the hybrid-VMAT plan were significantly less than those for the F-IMRT or the pure-VMAT plan. The mean machine delivery time was 3.23 ± 0.29 minutes for the hybrid-VMAT plans, which is longer than that for the pure-VMAT plans but shorter than that for the F-IMRT plans. The hybrid-VMAT plan is feasible for whole-breast irradiation of left-sided early breast cancer. PMID:26116150

  7. Feasibility study of a periodic arc compressor in the presence of coherent synchrotron radiation

    Science.gov (United States)

    Di Mitri, S.

    2016-01-01

    The advent of short electron bunches in high brightness linear accelerators has raised the awareness of the accelerator community to the degradation of the beam transverse emittance by coherent synchrotron radiation (CSR) emitted in magnetic bunch length compressors, transfer lines and turnaround arcs. Beam optics control has been proposed to mitigate that CSR effect. In this article, we enlarge on the existing literature by reviewing the validity of the linear optics approach in a periodic, achromatic arc compressor. We then study the dependence of the CSR-perturbed emittance to beam optics, mean energy, and bunch charge. The analytical findings are compared with particle tracking results. Practical considerations on CSR-induced energy loss and nonlinear particle dynamics are included. As a result, we identify the range of parameters that allows feasibility of an arc compressor for driving, for example, a free electron laser or a linear collider.

  8. Influence of Welding Current and Focal Position on the Resonant Absorption of Laser Radiation in a TIG Welding Arc

    Science.gov (United States)

    Emde, B.; Huse, M.; Hermsdorf, J.; Kaierle, S.; Wesling, V.; Overmeyer, L.

    The work presents the influence of welding current and focal position on the resonant absorption of diode laser radiation in a TIG welding arc. The laser beam is guided perpendicular to the electrical arc to avoid an interaction with the electrodes. Laser power measurements have shown a reduction of the measured laser power up to 18% after passing the electrical arc. This reduction results from the interaction of argon shielding gas atoms and laser radiation at 810.4 nm and 811.5 nm. The interaction is strongly affected by the adjusted welding current and the adjustment of the laser beam and the electrical arc. Lowering the welding current or shifting the laser beam out of the centerline of the electrical arc reduces the ionization probability. An increased ionization is necessary to decrease the resistance of the electrical arc.

  9. An efficient Volumetric Arc Therapy treatment planning approach for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Jin [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY (United States); Bender, Edward [Department of Medical Physics, University of Wisconsin, Madison, WI (United States); Yaparpalvi, Ravindra; Kuo, Hsiang-Chi; Basavatia, Amar; Hong, Linda; Bodner, William; Garg, Madhur K.; Kalnicki, Shalom [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY (United States); Tomé, Wolfgang A., E-mail: wtome@montefiore.org [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY (United States); Department of Medical Physics, University of Wisconsin, Madison, WI (United States)

    2015-10-01

    An efficient and simple class solution is proposed for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT) planning using the Volumetric Arc Therapy (VMAT) delivery technique following the NRG Oncology protocol NRG-CC001 treatment planning guidelines. The whole-brain planning target volume (PTV) was subdivided into subplanning volumes that lie in plane and out of plane with the hippocampal-avoidance volume. To further improve VMAT treatment plans, a partial-field dual-arc technique was developed. Both the arcs were allowed to overlap on the in-plane subtarget volume, and in addition, one arc covered the superior out-of-plane sub-PTV, while the other covered the inferior out-of-plane subtarget volume. For all plans (n = 20), the NRG-CC001 protocol dose-volume criteria were met. Mean values of volumes for the hippocampus and the hippocampal-avoidance volume were 4.1 cm{sup 3} ± 1.0 cm{sup 3} and 28.52 cm{sup 3} ± 3.22 cm{sup 3}, respectively. For the PTV, the average values of D{sub 2%} and D{sub 98%} were 36.1 Gy ± 0.8 Gy and 26.2 Gy ± 0.6 Gy, respectively. The hippocampus D{sub 100%} mean value was 8.5 Gy ± 0.2 Gy and the maximum dose was 15.7 Gy ± 0.3 Gy. The corresponding plan quality indices were 0.30 ± 0.01 (homogeneity index), 0.94 ± 0.01 (target conformality), and 0.75 ± 0.02 (confirmation number). The median total monitor unit (MU) per fraction was 806 MU (interquartile range [IQR]: 792 to 818 MU) and the average beam total delivery time was 121.2 seconds (IQR: 120.6 to 121.35 seconds). All plans passed the gamma evaluation using the 5-mm, 4% criteria, with γ > 1 of not more than 9.1% data points for all fields. An efficient and simple planning class solution for HA-WBRT using VMAT has been developed that allows all protocol constraints of NRG-CC001 to be met.

  10. Investigation in the use of plasma arc welding and alternative feedstock delivery method in additive manufacture

    Science.gov (United States)

    Alhuzaim, Abdullah F.

    The work conducted for this thesis was to investigate the use of plasma arc welding (PAW) and steel shot as a means of additive manufacturing. A robotic PAW system and automatic shot feeder were used to manufacture linear walls approximately 100 mm long by 7 mm wide and 20 mm tall. The walls were built, layer-by-layer, on plain carbon steel substrate by adding individual 2.5 mm diameter plain carbon steel shot. Each layer was built, shot-by-shot, using a pulse of arc current to form a molten pool on the deposit into which each shot was deposited and melted. The deposition rate, a measure of productivity, was approximately 50 g/hour. Three walls were built using the same conditions except for the deposit preheat temperature prior to adding each new layer. The deposit preheat temperature was controlled by allowing the deposit to cool after each layer for an amount of time called the inter-layer wait time. The walls were sectioned and grain size and hardness distribution were measured as a function of wall height. The results indicated that, for all specimens, deposit grain size increased and hardness decreased as wall height increased. Furthermore, average grain size decreased and hardness increased as interlayer wait time increased. An analytical heat flow model was developed to study the influence of interlayer wait time on deposit temperature and therefore grain size and hardness. The results of the model indicated that as wall height increased, the rate of deposit heat removal by conduction to the substrate decreased leading to a higher preheat temperature after a fixed interlayer wait time causing grain size to increase as wall height increased. However, the model results also show that as wall height increased, the deposit surface area from which heat energy is lost via convection and radiation increased. The model also demonstrated that the use of a means of forced convection to rapidly remove heat from the deposit could be an effective way to boost

  11. Radiation shielding properties of concrete with electric arc furnace slag aggregates and steel shots

    International Nuclear Information System (INIS)

    Highlights: ► Industrial waste products were used to produce radiation shielding concrete. ► The mechanical and radiation shielding properties were evaluated. ► The developed concrete is cheaper and conserves the natural resources. - Abstract: Heavyweight concrete, prepared with a mixture of concrete and heavyweight aggregates or metallic components, is generally used for radiation shielding purposes. In the present study the radiation shielding properties of concrete prepared with electric arc furnace slag aggregates (EAFSAs) and steel shots, was investigated. The results indicated that concrete mixed with 50% EAFSA and 50% steel shots meets the weight and radiation requirements. The use of 50% EAFSA results in a decrease in the cost of concrete and also conserves a useful material, such as iron ore

  12. Simulation of Fault Arc Based on Different Radiation Models in a Closed Tank

    Science.gov (United States)

    Li, Mei; Zhang, Junpeng; Hu, Yang; Zhang, Hantian; Wu, Yifei

    2016-05-01

    This paper focuses on the simulation of a fault arc in a closed tank based on the magneto-hydrodynamic (MHD) method, in which a comparative study of three radiation models, including net emission coefficients (NEC), semi-empirical model based on NEC as well as the P1 model, is developed. The pressure rise calculated by the three radiation models are compared to the measured results. Particularly when the semi-empirical model is used, the effect of different boundary temperatures of the re-absorption layer in the semi-empirical model on pressure rise is concentrated on. The results show that the re-absorption effect in the low-temperature region affects radiation transfer of fault arcs evidently, and thus the internal pressure rise. Compared with the NEC model, P1 and the semi-empirical model with 0.7<α<0.83 are more suitable to calculate the pressure rise of the fault arc, where is an adjusted parameter involving the boundary temperature of the re-absorption region in the semi-empirical model. supported by National Key Basic Research Program of China (973 Program) (No. 2015CB251002), National Natural Science Foundation of China (Nos. 51221005, 51177124), the Fundamental Research Funds for the Central Universities, the Program for New Century Excellent Talents in University and Shaanxi Province Natural Science Foundation of China (No. 2013JM-7010)

  13. Simulation of Fault Arc Based on Different Radiation Models in a Closed Tank

    Institute of Scientific and Technical Information of China (English)

    LI Mei; ZHANG Junpeng; HU Yang; ZHANG Hantian; WU Yifei

    2016-01-01

    This paper focuses on the simulation of a fault arc in a closed tank based on the magneto-hydrodynamic (MHD) method,in which a comparative study of three radiation models,including net emission coefficients (NEC),semi-empirical model based on NEC as well as the P1 model,is developed.The pressure rise calculated by the three radiation models are compared to the measured results.Particularly when the semi-empirical model is used,the effect of different boundary temperatures of the re-absorption layer in the semi-empirical model on pressure rise is concentrated on.The results show that the re-absorption effect in the low-temperature region affects radiation transfer of fault arcs evidently,and thus the internal pressure rise.Compared with the NEC model,P1 and the semi-empirical model with 0.7 < α < 0.83 are more suitable to calculate the pressure rise of the fault arc,where is an adjusted parameter involving the boundary temperature of the re-absorption region in the semi-empirical model.

  14. Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hae Youn; Seok, Jin Yong; Hong, Joo Wan; Chang, Nam Jun; Choi, Byeong Don; Park, Jin Hong [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Sangnam (Korea, Republic of)

    2015-06-15

    The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and R{sub 50%} was calculated to assess low dose spillage as per treatment plan. D{sub 50%} of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and R{sub 50%} on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum D{sub 50%} was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest

  15. Accuracy of Dose Delivery in Multiple Breath-Hold Segmented Volumetric Modulated Arc Therapy: A Static Phantom Study

    Directory of Open Access Journals (Sweden)

    Kimiya Noto

    2014-01-01

    Full Text Available Purpose. Accuracy of dose delivery in multiple breath-hold segmented volumetric modulated arc therapy (VMAT was evaluated in comparison to noninterrupted VMAT using a static phantom. Material and Methods. Five VMAT plans were evaluated. A Synergy linear accelerator (Elekta AB, Stockholm, Sweden was employed. A VMAT delivery sequence was divided into multiple segments according to each of the predefined breath-hold periods (10, 15, 20, 30, and 40 seconds. The segmented VMAT delivery was compared to noninterrupted VMAT delivery in terms of the isocenter dose and pass rates of a dose difference of 1% with a dose threshold of 10% of the maximum dose on a central coronal plane using a two-dimensional dosimeter, MatriXX Evolution (IBA Dosimetry, Schwarzenbruck, Germany. Results. Means of the isocenter dose differences were 0.5%, 0.2%, 0.2%, 0.0%, and 0.0% for the beam-on-times between interrupts of 10, 15, 20, 30, and 40 seconds, respectively. Means of the pass rates were 85%, 99.9%, 100%, 100%, and 100% in the same order as the above. Conclusion. Our static phantom study indicated that the multiple breath-hold segmented VMAT maintains stable and accurate dose delivery when the beam-on-time between interrupts is 15 seconds or greater.

  16. Hazard of ultraviolet radiation emitted in gas tungsten arc welding of aluminum alloys.

    Science.gov (United States)

    Nakashima, Hitoshi; Utsunomiya, Akihiro; Fujii, Nobuyuki; Okuno, Tsutomu

    2016-03-28

    Ultraviolet radiation (UVR) emitted during arc welding frequently causes keratoconjunctivitis and erythema. The extent of the hazard of UVR varies depending on the welding method and conditions. Therefore, it is important to identify the levels of UVR that are present under various conditions. In this study, we experimentally evaluated the hazard of UVR emitted in gas tungsten arc welding (GTAW) of aluminum alloys. The degree of hazard of UVR is measured by the effective irradiance defined in the American Conference of Governmental Industrial Hygienists guidelines. The effective irradiances measured in this study are in the range 0.10-0.91 mW/cm(2) at a distance of 500 mm from the welding arc. The maximum allowable exposure times corresponding to these levels are only 3.3-33 s/day. This demonstrates that unprotected exposure to UVR emitted by GTAW of aluminum alloys is quite hazardous in practice. In addition, we found the following properties of the hazard of UVR. (1) It is more hazardous at higher welding currents than at lower welding currents. (2) It is more hazardous when magnesium is included in the welding materials than when it is not. (3) The hazard depends on the direction of emission from the arc. PMID:26632121

  17. Hazard of ultraviolet radiation emitted in gas tungsten arc welding of aluminum alloys.

    Science.gov (United States)

    Nakashima, Hitoshi; Utsunomiya, Akihiro; Fujii, Nobuyuki; Okuno, Tsutomu

    2016-01-01

    Ultraviolet radiation (UVR) emitted during arc welding frequently causes keratoconjunctivitis and erythema. The extent of the hazard of UVR varies depending on the welding method and conditions. Therefore, it is important to identify the levels of UVR that are present under various conditions. In this study, we experimentally evaluated the hazard of UVR emitted in gas tungsten arc welding (GTAW) of aluminum alloys. The degree of hazard of UVR is measured by the effective irradiance defined in the American Conference of Governmental Industrial Hygienists guidelines. The effective irradiances measured in this study are in the range 0.10-0.91 mW/cm(2) at a distance of 500 mm from the welding arc. The maximum allowable exposure times corresponding to these levels are only 3.3-33 s/day. This demonstrates that unprotected exposure to UVR emitted by GTAW of aluminum alloys is quite hazardous in practice. In addition, we found the following properties of the hazard of UVR. (1) It is more hazardous at higher welding currents than at lower welding currents. (2) It is more hazardous when magnesium is included in the welding materials than when it is not. (3) The hazard depends on the direction of emission from the arc.

  18. Theoretical investigation of coherent synchrotron radiation induced microbunching instability in transport and recirculation arcs

    CERN Document Server

    Tsai, Cheng-Ying; Li, Rui; Tennant, Christopher

    2014-01-01

    The coherent synchrotron radiation (CSR) of a high brightness electron beam traversing a series of dipoles, such as recirculation or transport arcs, may lead to the microbunching instability. We extend and develop a semi-analytical approach of the CSR-induced microbunching instability for a general lattice, based on the previous formulation with 1-D CSR model [Phys. Rev. ST Accel. Beams 5, 064401 (2002)] and apply it to investigate the physical processes of microbunching amplification for two example transport arc lattices. We find that the microbunching instability in transport arcs has a distinguishing feature of multistage amplification (e.g, up to 6th stage for our example arcs in contrast to two stage amplification for a 3-dipole chicane). By further extending the concept of stage gain as proposed by Huang and Kim [Phys. Rev. ST Accel. Beams 5, 074401 (2002)], we developed a method to quantitatively characterize the microbunching amplification in terms of iterative or staged orders that allows the compar...

  19. Change of electrical conductivity of Ar welding arc under resonant absorption of laser radiation

    Science.gov (United States)

    Kozakov, R.; Emde, B.; Pipa, A. V.; Huse, M.; Uhrlandt, D.; Hermsdorf, J.; Wesling, V.

    2015-03-01

    Experimental investigations of the impact of resonant laser absorption by a tungsten inert gas welding arc in argon are presented. The intensity increase of the arc’s radiation between the laser entrance height and the anode are observed, as well as the variation of arc voltage due to the presence of the laser beam. High-speed camera recordings from different directions combined with absolutely calibrated spectroscopic measurements allow the reconstruction of the three-dimensional emission coefficient profiles without the assumption of axial symmetry. The obtained data are evaluated within the framework of local thermodynamic equilibrium. The local increase in the temperature and conductivity due to the influence of the laser is determined. Changes in the electrical conductivity obtained from the optical measurements coincide well with the measured voltage drop, and show significant redistribution of the current density profile near the anode in particular.

  20. Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jia-Fu [Department of Radiation Physics, Taichung Veterans General Hospital, Taichung, Taiwan (China); Yeh, Dah-Cherng [Department of General Surgery, Taichung Veterans General Hospital, Taichung, Taiwan (China); Yeh, Hui-Ling, E-mail: hlyeh@vghtc.gov.tw [Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung, Taiwan (China); Chang, Chen-Fa [Department of Radiation Physics, Taichung Veterans General Hospital, Taichung, Taiwan (China); Lin, Jin-Ching [Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung, Taiwan (China)

    2015-10-01

    To compare the dosimetric performance of 3 different treatment techniques: hybrid volumetric-modulated arc therapy (hybrid-VMAT), pure-VMAT, and fixed-field intensity-modulated radiation therapy (F-IMRT) for whole-breast irradiation of left-sided early breast cancer. The hybrid-VMAT treatment technique and 2 other treatment techniques—pure-VMAT and F-IMRT—were compared retrospectively in 10 patients with left-sided early breast cancer. The treatment plans of these patients were replanned using the same contours based on the original computed tomography (CT) data sets. Dosimetric parameters were calculated to evaluate plan quality. Total monitor units (MUs) and delivery time were also recorded and evaluated. The hybrid-VMAT plan generated the best results in dose coverage of the target and the dose uniformity inside the target (p < 0.0001 for conformal index [CI]; p = 0.0002 for homogeneity index [HI] of planning target volume [PTV]{sub 50.4} {sub Gy} and p < 0.0001 for HI of PTV{sub 62} {sub Gy}). Volumes of ipsilateral lung irradiated to doses of 20 Gy (V{sub 20} {sub Gy}) and 5 Gy (V{sub 5} {sub Gy}) by the hybrid-VMAT plan were significantly less than those of the F-IMRT and the pure-VMAT plans. The volume of ipsilateral lung irradiated to a dose of 5 Gy was significantly less using the hybrid-VMAT plan than that using the F-IMRT or the pure-VMAT plan. The total mean MUs for the hybrid-VMAT plan were significantly less than those for the F-IMRT or the pure-VMAT plan. The mean machine delivery time was 3.23 ± 0.29 minutes for the hybrid-VMAT plans, which is longer than that for the pure-VMAT plans but shorter than that for the F-IMRT plans. The hybrid-VMAT plan is feasible for whole-breast irradiation of left-sided early breast cancer.

  1. The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery

    Energy Technology Data Exchange (ETDEWEB)

    Falk, Marianne; Larsson, Tobias; Keall, Paul; Chul Cho, Byung; Aznar, Marianne; Korreman, Stine; Poulsen, Per; Munck af Rosenschoeld, Per [Radiation Medicine Research Center, Department of Radiation Oncology - 3994, Rigshospitalet, Blegdamsvej 9, DK - 2100 Copenhagen (Denmark) and Niels Bohr Institute, University of Copenhagen (Denmark); Radiation Medicine Research Center, Department of Radiation Oncology, Rigshospitalet, Copenhagen University Hospital (Denmark); Radiation Physics Laboratory, Sydney Medical School, University of Sydney (Australia); Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Radiation Medicine Research Center, Department of Radiation Oncology, Rigshospitalet, Copenhagen University Hospital, Denmark and Niels Bohr Institute, University of Copenhagen (Denmark); Radiation Medicine Research Center, Department of Radiation Oncology, Rigshospitalet, Copenhagen University Hospital (Denmark); Niels Bohr Institute, University of Copenhagen (Denmark) and Department of Science, Systems and Models, Roskilde University (Denmark); Department of Oncology, Aarhus University Hospital (Denmark); Radiation Medicine Research Center, Department of Radiation Oncology, Rigshospitalet, Copenhagen University Hospital (Denmark) and Niels Bohr Institute, University of Copenhagen (Denmark)

    2012-03-15

    Purpose: Real-time dynamic multileaf collimator (MLC) tracking for management of intrafraction tumor motion can be challenging for highly modulated beams, as the leaves need to travel far to adjust for target motion perpendicular to the leaf travel direction. The plan modulation can be reduced by using a leaf position constraint (LPC) that reduces the difference in the position of adjacent MLC leaves in the plan. The purpose of this study was to investigate the impact of the LPC on the quality of inversely optimized arc radiotherapy plans and the effect of the MLC motion pattern on the dosimetric accuracy of MLC tracking delivery. Specifically, the possibility of predicting the accuracy of MLC tracking delivery based on the plan modulation was investigated. Methods: Inversely optimized arc radiotherapy plans were created on CT-data of three lung cancer patients. For each case, five plans with a single 358 deg. arc were generated with LPC priorities of 0 (no LPC), 0.25, 0.5, 0.75, and 1 (highest possible LPC), respectively. All the plans had a prescribed dose of 2 Gy x 30, used 6 MV, a maximum dose rate of 600 MU/min and a collimator angle of 45 deg. or 315 deg. To quantify the plan modulation, an average adjacent leaf distance (ALD) was calculated by averaging the mean adjacent leaf distance for each control point. The linear relationship between the plan quality [i.e., the calculated dose distributions and the number of monitor units (MU)] and the LPC was investigated, and the linear regression coefficient as well as a two tailed confidence level of 95% was used in the evaluation. The effect of the plan modulation on the performance of MLC tracking was tested by delivering the plans to a cylindrical diode array phantom moving with sinusoidal motion in the superior-inferior direction with a peak-to-peak displacement of 2 cm and a cycle time of 6 s. The delivery was adjusted to the target motion using MLC tracking, guided in real-time by an infrared optical system

  2. Clinical application of RapidArc volumetric modulated arc therapy as a component in whole brain radiation therapy for poor prognostic, four or more multiple brain metastases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Heon; Lee, Kyu Chan; Choi, Jin Ho; Kim, Hye Young; Lee, Seok Ho; Sung, Ki Hoon; Kim, Yun Mi [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2012-06-15

    To determine feasibility of RapidArc in sequential or simultaneous integrated tumor boost in whole brain radiation therapy (WBRT) for poor prognostic patients with four or more brain metastases. Nine patients with multiple ({>=}4) brain metastases were analyzed. Three patients were classified as class II in recursive partitioning analysis and 6 were class III. The class III patients presented with hemiparesis, cognitive deficit, or apraxia. The ratio of tumor to whole brain volume was 0.8-7.9%. Six patients received 2-dimensional bilateral WBRT, (30 Gy/10- 12 fractions), followed by sequential RapidArc tumor boost (15-30 Gy/4-10 fractions). Three patients received RapidArc WBRT with simultaneous integrated boost to tumors (48-50 Gy) in 10-20 fractions. The median biologically effective dose to metastatic tumors was 68.1 Gy10 and 67.2 Gy10 and the median brain volume irradiated more than 100 Gy3 were 1.9% (24 cm3) and 0.8% (13 cm3) for each group. With less than 3 minutes of treatment time, RapidArc was easily applied to the patients with poor performance status. The follow-up period was 0.3-16.5 months. Tumor responses among the 6 patients who underwent follow-up magnetic resonance imaging were partial and stable in 3 and 3, respectively. Overall survival at 6 and 12 months were 66.7% and 41.7%, respectively. The local progression-free survival at 6 and 12 months were 100% and 62.5%, respectively. RapidArc as a component in whole brain radiation therapy for poor prognostic, multiple brain metastases is an effective and safe modality with easy application.

  3. Image-guided radiation therapy for treatment delivery and verification

    Science.gov (United States)

    Schubert, Leah Kayomi

    Target conformity and normal tissue sparing provided by modern radiation therapy techniques often result in steep dose gradients, which increase the need for more accurate patient setup and treatment delivery. Image guidance is starting to play a major role in determining the accuracy of treatment setup. A typical objective of image-guided radiation therapy (IGRT) is to minimize differences between planned and delivered treatment by imaging the patient prior to delivery. This step verifies and corrects for patient setup and is referred to as setup verification. This dissertation evaluates the efficacy of daily imaging for setup verification and investigates new uses of IGRT for potential improvements in treatment delivery. The necessity of daily imaging can first be determined by assessing differences in setup corrections between patient groups. Therefore, the first objective of this investigation was to evaluate the application of IGRT for setup verification by quantifying differences in patient positioning for several anatomical disease sites. Detailed analysis of setup corrections for brain, head and neck, lung, and prostate treatments is presented. In this analysis, large setup errors were observed for prostate treatments. Further assessment of prostate treatments was performed, and patient-specific causes of setup errors investigated. Setup corrections are applied via rigid shifts or rotations of the patient or machine, but anatomical deformations occur for which rigid shifts cannot correct. Fortunately, IGRT provides images on which anatomical changes occurring throughout the course of treatment can be detected. From those images, the efficacy of IGRT in ensuring accurate treatment delivery can be evaluated and improved by determining delivered doses and adapting the plan during treatment. The second objective of this dissertation was to explore new applications of IGRT to further improve treatment. By utilizing daily IGRT images, a retrospective analysis of

  4. Developing system for delivery of optical radiation in medicobiological researches

    Science.gov (United States)

    Loschenov, Victor B.; Taraz, Majid

    2004-06-01

    Methods of optical diagnostics and methods of photodynamic therapy are actively used in medico-biological researches. The system for delivery of optical radiation is one of the key methods in these researches. Usually these systems use flexible optical fibers with diameters from 200 to 1000 micron. Two types of systems for delivery are subdivided, first for diagnostic researches, second for therapeutic procedures. Existing diagnostic catheters, which have most widely applied in medicine, have bifurcated with diameter of the tip equal 1.8 mm. These devices, which are called fiber-optical catheters, satisfy the majority endoscopes researches. However, till now the problem of optical-diagnostics inside tissue is not soled. Especially it is important at diagnostics of a mammary gland, livers, thyroid glands tumor, tumor of a brain and some other studies connected with punctures. In these cases, it is necessary that diameter of fiber-optical catheters be less than one millimeter. This work is devoted to the development of these catheters. Also in clinical procedures such as photodynamic therapy (PDT) and interstitial laser photocoagulation (ILP), cylindrical light diffusing tips are rapidly becoming a popular device for the administration of the desired light dose for the illumination of hollow organs, such as bronchus, trachea and oesophagus. This work is devoted to the development of these catheters.

  5. Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation—A comparison with traditional techniques

    International Nuclear Information System (INIS)

    Craniospinal irradiation (CSI) poses a challenging planning process because of the complex target volume. Traditional 3D conformal CSI does not spare any critical organs, resulting in toxicity in patients. Here the dosimetric advantages of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are compared with classic conformal planning in adults for both cranial and spine fields to develop a clinically feasible technique that is both effective and efficient. Ten adult patients treated with CSI were retrospectively identified. For the cranial fields, 5-field IMRT and dual 356° VMAT arcs were compared with opposed lateral 3D conformal radiotherapy (3D-CRT) fields. For the spine fields, traditional posterior-anterior (PA) PA fields were compared with isocentric 5-field IMRT plans and single 200° VMAT arcs. Two adult patients have been treated using this IMRT technique to date and extensive quality assurance, especially for the junction regions, was performed. For the cranial fields, the IMRT technique had the highest planned target volume (PTV) maximum and was the least efficient, whereas the VMAT technique provided the greatest parotid sparing with better efficiency. 3D-CRT provided the most efficient delivery but with the highest parotid dose. For the spine fields, VMAT provided the best PTV coverage but had the highest mean dose to all organs at risk (OAR). 3D-CRT had the highest PTV and OAR maximum doses but was the most efficient. IMRT provides the greatest OAR sparing but the longest delivery time. For those patients with unresectable disease that can benefit from a higher, definitive dose, 3D-CRT–opposed laterals are the most clinically feasible technique for cranial fields and for spine fields. Although inefficient, the IMRT technique is the most clinically feasible because of the increased mean OAR dose with the VMAT technique. Quality assurance of the beams, especially the junction regions, is essential

  6. Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation—A comparison with traditional techniques

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Shen, Xinglei; Yu, Yan; Xiao, Ying; Shi, Wenyin [Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Biswas, Tithi [Department of Radiation Oncology, Brody School of Medicine, East Carolina University, Greenville, NC (United States); Werner-Wasik, Maria; Harrison, Amy S. [Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2013-04-01

    Craniospinal irradiation (CSI) poses a challenging planning process because of the complex target volume. Traditional 3D conformal CSI does not spare any critical organs, resulting in toxicity in patients. Here the dosimetric advantages of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are compared with classic conformal planning in adults for both cranial and spine fields to develop a clinically feasible technique that is both effective and efficient. Ten adult patients treated with CSI were retrospectively identified. For the cranial fields, 5-field IMRT and dual 356° VMAT arcs were compared with opposed lateral 3D conformal radiotherapy (3D-CRT) fields. For the spine fields, traditional posterior-anterior (PA) PA fields were compared with isocentric 5-field IMRT plans and single 200° VMAT arcs. Two adult patients have been treated using this IMRT technique to date and extensive quality assurance, especially for the junction regions, was performed. For the cranial fields, the IMRT technique had the highest planned target volume (PTV) maximum and was the least efficient, whereas the VMAT technique provided the greatest parotid sparing with better efficiency. 3D-CRT provided the most efficient delivery but with the highest parotid dose. For the spine fields, VMAT provided the best PTV coverage but had the highest mean dose to all organs at risk (OAR). 3D-CRT had the highest PTV and OAR maximum doses but was the most efficient. IMRT provides the greatest OAR sparing but the longest delivery time. For those patients with unresectable disease that can benefit from a higher, definitive dose, 3D-CRT–opposed laterals are the most clinically feasible technique for cranial fields and for spine fields. Although inefficient, the IMRT technique is the most clinically feasible because of the increased mean OAR dose with the VMAT technique. Quality assurance of the beams, especially the junction regions, is essential.

  7. Modeling and Simulation of Radiative Compressible Flows in Aerodynamic Heating Arc-Jet Facility

    Science.gov (United States)

    Bensassi, Khalil; Laguna, Alejandro A.; Lani, Andrea; Mansour, Nagi N.

    2016-01-01

    Numerical simulations of an arc heated flow inside NASA's 20 [MW] Aerodynamics heating facility (AHF) are performed in order to investigate the three-dimensional swirling flow and the current distribution inside the wind tunnel. The plasma is considered in Local Thermodynamics Equilibrium(LTE) and is composed of Air-Argon gas mixture. The governing equations are the Navier-Stokes equations that include source terms corresponding to Joule heating and radiative cooling. The former is obtained by solving an electric potential equation, while the latter is calculated using an innovative massively parallel ray-tracing algorithm. The fully coupled system is closed by the thermodynamics relations and transport properties which are obtained from Chapman-Enskog method. A novel strategy was developed in order to enable the flow solver and the radiation calculation to be preformed independently and simultaneously using a different number of processors. Drastic reduction in the computational cost was achieved using this strategy. Details on the numerical methods used for space discretization, time integration and ray-tracing algorithm will be presented. The effect of the radiative cooling on the dynamics of the flow will be investigated. The complete set of equations were implemented within the COOLFluiD Framework. Fig. 1 shows the geometry of the Anode and part of the constrictor of the Aerodynamics heating facility (AHF). Fig. 2 shows the velocity field distribution along (x-y) plane and the streamline in (z-y) plane.

  8. Geometric Verification of Dynamic Wave Arc Delivery With the Vero System Using Orthogonal X-ray Fluoroscopic Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Burghelea, Manuela, E-mail: manuela.buleteanu@yahoo.com [Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels (Belgium); Faculty of Physics, Babes Bolyai University, Cluj-Napoca (Romania); R& D Radiosurgery, BrainLAB AG, Munich (Germany); Verellen, Dirk; Poels, Kenneth; Gevaert, Thierry [Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels (Belgium); Depuydt, Tom [Department of Radiation Oncology, University Hospitals Leuven, Leuven (Belgium); Tournel, Koen [Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels (Belgium); Hung, Cecilia [R& D Radiosurgery, BrainLAB AG, Munich (Germany); Simon, Viorica; Hiraoka, Masahiro [Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan); Ridder, Mark de [Department of Radiotherapy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels (Belgium)

    2015-07-15

    Purpose: The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry–ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. Methods and Materials: A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation was calculated as the maximum 3-dimensional distance between the CP and the closest DetPositions. Results: In the CP versus DetPositions comparison, an overall mean G/R deviation of 0.13°/0.16° ± 0.16°/0.16° was obtained, with a maximum G/R deviation of 0.6°/0.2°. For the LogActed versus DetPositions evaluation, the overall mean deviation was 0.08°/0.15° ± 0.10°/0.10° with a maximum G/R of 0.3°/0.4°. The largest decoupled deviations registered for gantry and ring were 0.6° and 0.4° respectively. No directional dependence was observed between clockwise and counterclockwise rotations. Doubling the dose resulted in a double number of detected points around each CP, and an angular deviation reduction in all cases. Conclusions: An independent geometric quality assurance approach was developed for DWA delivery verification and was successfully applied on diverse trajectories. Results showed that the Vero system is capable of following complex

  9. Trajectory Modulated Arc Therapy: A Fully Dynamic Delivery With Synchronized Couch and Gantry Motion Significantly Improves Dosimetric Indices Correlated With Poor Cosmesis in Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Jieming; Atwood, Todd; Eyben, Rie von; Fahimian, Benjamin; Chin, Erika; Horst, Kathleen [Department of Radiation Oncology, Stanford University, California (United States); Otto, Karl [Department of Physics, University of British Columbia, British Columbia (Canada); Hristov, Dimitre, E-mail: dimitre.hristov@stanford.edu [Department of Radiation Oncology, Stanford University, California (United States)

    2015-08-01

    Purpose: To develop planning and delivery capabilities for linear accelerator–based nonisocentric trajectory modulated arc therapy (TMAT) and to evaluate the benefit of TMAT for accelerated partial breast irradiation (APBI) with the patient in prone position. Methods and Materials: An optimization algorithm for volumetrically modulated arc therapy (VMAT) was generalized to allow for user-defined nonisocentric TMAT trajectories combining couch rotations and translations. After optimization, XML scripts were automatically generated to program and subsequently deliver the TMAT plans. For 10 breast patients in the prone position, TMAT and 6-field noncoplanar intensity modulated radiation therapy (IMRT) plans were generated under equivalent objectives and constraints. These plans were compared with regard to whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose. Results: For TMAT APBI, nonisocentric collision-free horizontal arcs with large angular span (251.5 ± 7.9°) were optimized and delivered with delivery time of ∼4.5 minutes. Percentage changes of whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose for TMAT relative to IMRT were −10.81% ± 6.91%, −27.81% ± 7.39%, −14.82% ± 9.67%, and 39.40% ± 10.53% (P≤.01). Conclusions: This is a first demonstration of end-to-end planning and delivery implementation of a fully dynamic APBI TMAT. Compared with IMRT, TMAT resulted in marked reduction of the breast tissue volume irradiated at high doses.

  10. Application of modified dynamic conformal arc (MDCA) technique on liver stereotactic body radiation therapy (SBRT) planning following RTOG 0438 guideline

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Chengyu, E-mail: shicy1974@yahoo.com; Chen, Yong; Fang, Deborah; Iannuzzi, Christopher

    2015-04-01

    Liver stereotactic body radiation therapy (SBRT) is a feasible treatment method for the nonoperable, patient with early-stage liver cancer. Treatment planning for the SBRT is very important and has to consider the simulation accuracy, planning time, treatment efficiency effects etc. The modified dynamic conformal arc (MDCA) technique is a 3-dimensional conformal arc planning method, which has been proposed for liver SBRT planning at our center. In this study, we compared the MDCA technique with the RapidArc technique in terms of planning target volume (PTV) coverage and sparing of organs at risk (OARs). The results show that the MDCA technique has comparable plan quality to RapidArc considering PTV coverage, hot spots, heterogeneity index, and effective liver volume. For the 5 PTVs studied among 4 patients, the MDCA plan, when compared with the RapidArc plan, showed 9% more hot spots, more heterogeneity effect, more sparing of OARs, and lower liver effective volume. The monitor unit (MU) number for the MDCA plan is much lower than for the RapidArc plans. The MDCA plan has the advantages of less planning time, no-collision treatment, and a lower MU number.

  11. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study.

    Science.gov (United States)

    Lee, Katrina; Lenards, Nishele; Holson, Janice

    2016-01-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient׳s neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient׳s data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain. PMID:26235550

  12. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    Directory of Open Access Journals (Sweden)

    Foroudi Farshad

    2012-07-01

    Full Text Available Abstract Background To compare 3 Dimensional Conformal radiotherapy (3D-CRT with Intensity Modulated Radiotherapy (IMRT with Volumetric-Modulated Arc Therapy (VMAT for bladder cancer. Methods Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Results Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293 for 3D-CRT; 824 (range 641–1083 for IMRT; and 403 (range 333–489 for VMAT (P  Conclusions VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.

  13. The Use of Medical Images in Planning and Delivery of Radiation Therapy

    OpenAIRE

    Kalet, Ira J; Austin-Seymour, Mary M.

    1997-01-01

    The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast to diagnostic radiology, where the focus is on interpretation of the images to decide if disease is present, radiation therapy quantifies the extent of the region to be treated, and relates it to the proposed treatment using a quantitative modeling system called a radiation treatment planning (RTP...

  14. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    International Nuclear Information System (INIS)

    To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293) for 3D-CRT; 824 (range 641–1083) for IMRT; and 403 (range 333–489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01–3:09) for 3D-CRT; 4:39 (range 3:41–6:40) for IMRT; and 1:14 (range 1:13–1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum. VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours

  15. Cherenkov imaging during volumetric modulated arc therapy for real-time radiation beam tracking and treatment response monitoring

    Science.gov (United States)

    Andreozzi, Jacqueline M.; Zhang, Rongxiao; Glaser, Adam K.; Gladstone, David J.; Jarvis, Lesley A.; Pogue, Brian W.

    2016-03-01

    External beam radiotherapy utilizes high energy radiation to target cancer with dynamic, patient-specific treatment plans. The otherwise invisible radiation beam can be observed via the optical Cherenkov photons emitted from interaction between the high energy beam and tissue. Using a specialized camera-system, the Cherenkov emission can thus be used to track the radiation beam on the surface of the patient in real-time, even for complex cases such as volumetric modulated arc therapy (VMAT). Two patients undergoing VMAT of the head and neck were imaged and analyzed, and the viability of the system to provide clinical feedback was established.

  16. Formation of Multicharged Metal Ions in Vacuum Arc Plasma Heated by Gyrotron Radiation%Formation of Multicharged Metal Ions in Vacuum Arc Plasma Heated by Gyrotron Radiation

    Institute of Scientific and Technical Information of China (English)

    G. Yu. YUSHKOV; K. P. SAVKIN; A. G. NIKOLAEV; E. M. OKS; A.V. VODOPYANOV; I. V. IZOTOV; D. A. MANSFELD

    2011-01-01

    A new method for the generation of high charged state metal ion beams is developed. This method is based on microwave heating of vacuum arc plasma in a magnetic trap under electron cyclotron resonance (ECR) conditions. Two gyrotrons for plasma heating were used, which were with the following parameters. The first is with a wave frequency of 37.5 GHz, a pulse duration of 1 ms and power of 100 kW, another is with 75 GHz, 0.15 ms and 400 kW. Two different magnetic traps were considered for vacuum arc plasma confinement. The first one is a simple mirror trap. Such system was already investigated and could provide high charge state ions. The second trap was with a cusp magnetic field configuration with native "minimum-B" field structure. Two different ways of metal plasma injection into the magnetic trap were used. The first one is an axial injection from an arc source located out of the trap, and the second is a radial injection from four arc sources mounted at the center of the trap. Both traps provide up to 200 eMA of ion beam current for platinum ions with highest charge state 10+. Ion beams were successfully extracted from the plasma and accelerated by a voltage of up to 20 kV.

  17. Experimental measurements and Monte Carlo simulations for dosimetric evaluations of intrafraction motion for gated and ungated intensity modulated arc therapy deliveries

    Science.gov (United States)

    Oliver, Mike; Gladwish, Adam; Staruch, Robert; Craig, Jeff; Gaede, Stewart; Chen, Jeff; Wong, Eugene

    2008-11-01

    Respiratory gated radiation therapy allows for a smaller margin expansion for the planning target volume (PTV) to account for respiratory induced motion and is emerging as a common method to treat lung and liver tumors. We investigated the dosimetric effect of free motion and gated delivery for intensity modulated arc therapy (IMAT) with experimental measurements and Monte Carlo simulations. The impact of PTV margin and duty cycle for gated delivery is studied with Monte Carlo simulations. A motion phantom is used for this study. Two sets of contours were drawn on the mid-inspiration CT scan of this motion phantom. For each set of contours, an IMAT plan to be delivered with constant dose rate was created. The plans were generated on a CT scan of the phantom in the static condition with 3 mm PTV margin and applied to the motion phantom under four conditions: static, full superior-inferior (SI) motion (A = 1 cm, T = 4 s) and gating conditions (25% and 50% duty cycles) with full SI motion. A 6 by 15 cm piece of radiographic film was placed in the sagittal plane of the phantom and then irradiated under all measurement conditions. Film calibration was performed with a step-wedge method to convert optical density to dose. Gated IMAT delivery was first validated in 2D by comparing static film with that from gating and full motion. A previously verified simulation tool for IMRT that takes the log files from the multileaf collimator (MLC) controller and the gating system were adapted to simulate the delivered IMAT treatment for full 3D dosimetric analysis. The IMAT simulations were validated against the 2D film measurements. The resultant IMAT simulations were evaluated with dose criteria, dose-volume histograms and 3D gamma analysis. We validated gated IMAT deliveries when we compared the static film with the one from gating using 25% duty cycle using 2D gamma analysis. Within experimental and setup uncertainties, film measurements agreed with their corresponding simulated

  18. Reducing the low-dose lung radiation for central lung tumors by restricting the IMRT beams and arc arrangement.

    Science.gov (United States)

    Rosca, Florin; Kirk, Michael; Soto, Daniel; Sall, Walter; McIntyre, James

    2012-01-01

    To compare the extent to which 7 different radiotherapy planning techniques for mediastinal lung targets reduces the lung volume receiving low doses of radiation. Thirteen non-small cell lung cancer patients with targets, including the mediastinal nodes, were identified. Treatment plans were generated to both 60- and 74-Gy prescription doses using 7 different planning techniques: conformal, hybrid conformal/intensity-modulated radiation treatment (IMRT), 7 equidistant IMRT beams, 2 restricted beam IMRT plans, a full (360°) modulated arc, and a restricted modulated arc plan. All plans were optimized to reduce total lung V5, V10, and V20 volumes, while meeting normal tissue and target coverage constraints. The mean values for the 13 patients are calculated for V5, V10, V20, V(ave), V0-20, and mean lung dose (MLD) lung parameters. For the 74-Gy prescription dose, the mean lung V10 was 42.7, 43.6, 48.2, 56.6, 57, 55.8, and 54.1% for the restricted ±36° IMRT, restricted modulated arc, restricted ±45° IMRT, full modulated arc, hybrid conformal/IMRT, equidistant IMRT, and conformal plans, respectively. A similar lung sparing hierarchy was found for the 60-Gy prescription dose. For the treatment of central lung targets, the ±36° restricted IMRT and restricted modulated arc planning techniques are superior in lowering the lung volume treated to low dose, as well as in minimizing MLD, followed by the ±45° restricted IMRT plan. All planning techniques that allow the use of lateral or lateral/oblique beams result in spreading the low dose over a higher lung volume. The area under the lung dose-volume histogram curve below 20 Gy, V0-20, is proposed as an alternative to individual V(dose) parameters, both as a measure of lung sparing and as a parameter to be minimized during IMRT optimization. PMID:22189028

  19. Simulating Proton Synchrotron Radiation in the Arcs of the LHC, HL-LHC, and FCC-hh

    CERN Document Server

    Canton, Gerardo Guillermo; Zimmermann, Frank

    2016-01-01

    At high proton-beam energies, beam-induced synchrotron radiation is an important source of heating, of beam-related vacuum pressure increase, and of primary photoelectrons, which can give rise to an electron cloud. We use the Synrad3D code developed at Cornell to simulate the photon distributions in the arcs of the LHC, HL-LHC, and FCC-hh. Specifically, for the LHC we study the effect of the “sawtooth” chamber, for the HL-LHC the consequences of the ATS optics with large beta beating in the arcs, and for the FCC-hh the effect of a novel beam-screen design, with a long slit surrounded by a “folded” antechamber.

  20. Dosimetric effects of weight loss or gain during volumetric modulated arc therapy and intensity-modulated radiation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pair, Matthew L. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Du, Weiliang [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Rojas, Hector D.; Kanke, James E.; McGuire, Sean E.; Lee, Andrew K.; Kuban, Deborah A. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J., E-mail: rkudchad@mdanderson.org [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2013-10-01

    Weight loss or gain during the course of radiation therapy for prostate cancer can alter the planned dose to the target volumes and critical organs. Typically, source-to-surface distance (SSD) measurements are documented by therapists on a weekly basis to ensure that patients' exterior surface and isocenter-to-skin surface distances remain stable. The radiation oncology team then determines whether the patient has undergone a physical change sufficient to require a new treatment plan. The effect of weight change (SSD increase or decrease) on intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) dosimetry is not well known, and it is unclear when rescanning or replanning is needed. The purpose of this study was to determine the effects of weight change (SSD increase or decrease) on IMRT or VMAT dose delivery in patients with prostate cancer and to determine the SSD change threshold for replanning. Whether IMRT or VMAT provides better dose stability under weight change conditions was also determined. We generated clinical IMRT and VMAT prostate and seminal vesicle treatment plans for varying SSDs for 10 randomly selected patients with prostate cancer. The differences due to SSD change were quantified by a specific dose change for a specified volume of interest. The target mean dose, decreased or increased by 2.9% per 1-cm SSD decrease or increase in IMRT and by 3.6% in VMAT. If the SSD deviation is more than 1 cm, the radiation oncology team should determine whether to continue treatment without modifications, to adjust monitor units, or to resimulate and replan.

  1. Reducing the low-dose lung radiation for central lung tumors by restricting the IMRT beams and arc arrangement

    Energy Technology Data Exchange (ETDEWEB)

    Rosca, Florin, E-mail: frosca@partners.org [Department of Radiation Oncology, Mass General/North Shore, Danvers, MA (United States); Kirk, Michael; Soto, Daniel; Sall, Walter; McIntyre, James [Department of Radiation Oncology, Mass General/North Shore, Danvers, MA (United States)

    2012-10-01

    To compare the extent to which 7 different radiotherapy planning techniques for mediastinal lung targets reduces the lung volume receiving low doses of radiation. Thirteen non-small cell lung cancer patients with targets, including the mediastinal nodes, were identified. Treatment plans were generated to both 60- and 74-Gy prescription doses using 7 different planning techniques: conformal, hybrid conformal/intensity-modulated radiation treatment (IMRT), 7 equidistant IMRT beams, 2 restricted beam IMRT plans, a full (360 Degree-Sign ) modulated arc, and a restricted modulated arc plan. All plans were optimized to reduce total lung V5, V10, and V20 volumes, while meeting normal tissue and target coverage constraints. The mean values for the 13 patients are calculated for V5, V10, V20, V{sub ave}, V0-20, and mean lung dose (MLD) lung parameters. For the 74-Gy prescription dose, the mean lung V10 was 42.7, 43.6, 48.2, 56.6, 57, 55.8, and 54.1% for the restricted {+-}36 Degree-Sign IMRT, restricted modulated arc, restricted {+-}45 Degree-Sign IMRT, full modulated arc, hybrid conformal/IMRT, equidistant IMRT, and conformal plans, respectively. A similar lung sparing hierarchy was found for the 60-Gy prescription dose. For the treatment of central lung targets, the {+-}36 Degree-Sign restricted IMRT and restricted modulated arc planning techniques are superior in lowering the lung volume treated to low dose, as well as in minimizing MLD, followed by the {+-}45 Degree-Sign restricted IMRT plan. All planning techniques that allow the use of lateral or lateral/oblique beams result in spreading the low dose over a higher lung volume. The area under the lung dose-volume histogram curve below 20 Gy, V0-20, is proposed as an alternative to individual V{sub dose} parameters, both as a measure of lung sparing and as a parameter to be minimized during IMRT optimization.

  2. Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

    Energy Technology Data Exchange (ETDEWEB)

    Feygelman, Vladimir; Zhang, Geoffrey; Hunt, Dylan; Opp, Daniel [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States); Stambaugh, Cassandra [Department of Physics, University of South Florida, Tampa, Florida 33612 (United States); Wolf, Theresa K. [Live Oak Technologies LLC, Kirkwood, Missouri 63122 (United States); Nelms, Benjamin E. [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States)

    2013-02-15

    Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT

  3. SU-E-T-62: Cardiac Toxicity in Dynamic Conformal Arc Therapy, Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy of Lung Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Ming, X; Zhang, Y [Tianjin University, Tianjin (China); Yale University, New Haven, CT, US (United States); Feng, Y [Tianjin University, Tianjin (China); Zhou, L [West China Hospital, Sichuan (China); Yale University, New Haven, CT, US (United States); Deng, J [Yale University, New Haven, CT, US (United States)

    2014-06-01

    Purpose: The cardiac toxicity for lung cancer patients, each treated with dynamic conformal arc therapy (DAT), intensity-modulated radiation therapy (IMRT), or volumetric modulated arc therapy (VMAT) is investigated. Methods: 120 lung patients were selected for this study: 25 treated with DAT, 50 with IMRT and 45 with VMAT. For comparison, all plans were generated in the same treatment planning system, normalized such that the 100% isodose lines encompassed 95% of planning target volume. The plan quality was evaluated in terms of homogeneity index (HI) and 95% conformity index (%95 CI) for target dose coverage and mean dose, maximum dose, V{sub 30} Gy as well as V{sub 5} Gy for cardiac toxicity analysis. Results: When all the plans were analyzed, the VMAT plans offered the best target coverage with 95% CI = 0.992 and HI = 1.23. The DAT plans provided the best heart sparing with mean heart dose = 2.3Gy and maximum dose = 11.6Gy, as compared to 5.7 Gy and 31.1 Gy by IMRT as well as 4.6 Gy and 30.9 Gy by VMAT. The mean V30Gy and V5Gy of the heart in the DAT plans were up to 11.7% lower in comparison to the IMRT and VMAT plans. When the tumor volume was considered, the VMAT plans spared up to 70.9% more doses to the heart when the equivalent diameter of the tumor was larger than 4cm. Yet the maximum dose to the heart was reduced the most in the DAT plans with up to 139.8% less than that of the other two plans. Conclusion: Overall, the VMAT plans achieved the best target coverage among the three treatment modalities, and would spare the heart the most for the larger tumors. The DAT plans appeared advantageous in delivering the least maximum dose to the heart as compared to the IMRT and VMAT plans.

  4. Impacts Of Radiatively-Active Aerosols On Mars’ Current Climate: Simulation Results With The NASA ARC Mars GCM

    Science.gov (United States)

    Hollingsworth, Jeffery L.; Kahre, M. A.; Haberle, R. M.; Montmessin, F.; Herin, B.; Laamoumi, F.; Wilson, R. J.; Schaeffer, J.

    2010-10-01

    Recent upgrades to the NASA Ames Research Center (ARC) Mars general circulation model (GCM) include a fundamentally new and modernized radiative transfer package which permits radiative effects and interactions of suspended atmospheric aerosols (e.g., water ice clouds, water vapor, dust, and their mutual interactions) to influence the net diabatic heating rate within the atmosphere. Such aerosols are critically important in determining the nature of atmospheric thermal structure and hence the overall climate of the planet. Our Mars GCM simulations indicate that radiatively-active water ice clouds profoundly affect the seasonal and annual mean climate in a variety of ways. In particular, preliminary results suggest that the bulk thermal structure and resultant (i.e., balanced) circulation patterns are strongly modified near the surface and aloft. Generally speaking, we find a bulk warming of the atmosphere in upper layers, a cooling of the atmosphere in the lower and near-surface regions, and, increases in the mean pole-to-equator temperature contrasts (i.e., stronger mean polar vortices). A variety of results from our baseline and control simulations (i.e., where the radiative/physical effects are examined in isolation and when combined) will be presented. Comparisons with MGS/TES and MRO/MCS measurements indicate better agreement between the model's simulated climate compared to that observed. Using a state-of-the-art Mars GCM, these results highlight important effects radiatively-active aerosols have on physical and dynamical processes active in the current climate of Mars.

  5. Radiation dose in radiotherapy from prescription to delivery

    International Nuclear Information System (INIS)

    Cancer incidence is increasing in developed as well as in developing countries. Cancer may be expected to become a prominent problem and this will result in public pressure for higher priorities on cancer care. In some relatively advanced developing countries radiation therapy is applied in about 50% of all detected cancer cases. Approximately half of these treatments have curative intent. Surgery and radiotherapy applied individually or combined result in the cure of about 40% of all patients. The application of chemotherapy alone has curative effects only on a small percentage of cancer patients. It is encouraging to note that the results achieved by radiation therapy show continuous improvement. This can be traced back to a number of developments: increased knowledge regarding tumour and normal tissue response to radiation, early diagnosis with improved tumour localisation, improved dosimetry and dose planning. The introduction of modern equipment has been crucial in these developments and makes possible a more accurate target delineation, better treatment planning resulting in irradiation of the Planning Target Volume (PTV) with a highly uniform dose and, simultaneously, a reduction in dose to healthy tissues outside the PTV. Experience shows that high quality radiotherapy can only be achieved if its conducted by a skilled team working closely together with good communication between various categories of staff. Therefore, seminars and training courses covering all aspects of radiotherapy and dosimetry are of great importance and should be held regionally or nationally on a regular basis. Refs, figs, tabs

  6. Hypofractionation does not increase radiation pneumonitis risk with modern conformal radiation delivery techniques

    DEFF Research Database (Denmark)

    Vogelius, Ivan R; Westerly, David C; Cannon, George M;

    2010-01-01

    To study the interaction between radiation dose distribution and hypofractionated radiotherapy with respect to the risk of radiation pneumonitis (RP) estimated from normal tissue complication probability (NTCP) models.......To study the interaction between radiation dose distribution and hypofractionated radiotherapy with respect to the risk of radiation pneumonitis (RP) estimated from normal tissue complication probability (NTCP) models....

  7. TH-C-12A-09: Planning and Delivery of the Fully Dynamic Trajectory Modulated Arc Therapy: Application to Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Liang, J; Atwood, T; Fahimian, B; Chin, E; Hristov, D [Department of Radiation Oncology, Stanford University, CA (United States); Otto, K [Department of Physics, University of British Columbia, BC (Canada)

    2014-06-15

    Purpose: A novel trajectory modulated arc therapy (TMAT) system was developed that uses source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement. MLC motion and dose rate were fully optimized for dynamic beam delivery. This work presents a platform for planning deliverable TMAT on a collision free coronal trajectory and evaluates its benefit for accelerated partial breast irradiation (APBI) in a prone position. Methods: The TMAT algorithm was built on VMAT with modifications (physical properties on couch movement were defined) and enhancements (pencil beam dose calculation engine to support extended SSDs) to make it feasible for TMAT delivery. A Matlab software environment for TMAT optimization and dose calculation was created to allow any user specified motion axis. TMAT delivery was implemented on Varian TrueBeamTM STx via XML scripts. 10 prone breast irradiation cases were evaluated in VMAT and compared with a 6- field non-coplanar IMRT plan. Patient selection/exclusion criteria and structure contouring followed the guidelines of NSABP B-39/RTOG 0413 protocol. Results: TMAT delivery time was ∼4.5 minutes. 251.5°±7.88° of non-isocentric couch arc was achieved by the optimized trajectory with 180– 210 control points at 1°–2° couch increments. The improved dose distribution by TMAT was most clearly observed by the marked reduction in the volume of irradiated normal breast tissue in the high dose region. The ratios of the normal breast tissue volume receiving more than 50%, 80% and 100% of the prescription dose for TMAT versus IMRT were: V50%(TMAT/IMRT) = 78.38%±13.03%, V80%(TMAT/IMRT) = 44.19%±9.04% and V100% (TMAT/IMRT) = 9.96%±7.55%, all p≤0.01. Conclusion: The study is the first demonstration of planning and delivery implementation of a fully dynamic APBI TMAT system with continuous couch motion. TMAT achieved significantly improved dosimetry over noncoplanar IMRT on dose volume parameters

  8. SU-E-P-14: Dosimetric Effects of Magnetic Field in MRI-Guided Radiation Therapy Delivery for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chen, G; Currey, A; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2015-06-15

    Purpose: MRI-guided radiation therapy (RT) delivery would be beneficial for breast irradiation. The electron return effect due to the presence of a transverse magnetic field (TMF) may cause dosimetric issues on dose on skin and at the lung-tissue interface. The purpose of this study is to investigate these issues. Methods: IMRT plans with tangential beams and VMAT plans with 200 degree arcs to cover ipsilateral breast were generated for 10 randomly selected breast cancer cases using a research planning system (Monaco, Elekta) utilizing Monte Carlo dose calculation with or without a TMF of 1.5 T. Plans were optimized to deliver uniform dose to the whole breast with an exclusion of 5 mm tissue under the skin (PTV-EVAL). All four plans for each patient were re-scaled to have the same PTV-EVAL volume to receive the same prescription dose. The skin is defined as the first 5 mm of ipsilateral-breast tissue, plus extensions in the surrounding region. Results: The presence of 1.5 T TMF resulted in (1)increased skin dose, with the mean and maximum skin dose increase of 5% and 9%, respectively; (2) similar dose homogeneity within the PTV-EVAL; (3) the slightly improved (3%) dose homogeneity in the whole breast; (4) Averages of 9 and 16% increases in V5 and V20, respectively, for ipsilateral lung; and (5) increased the mean heart dose by 34%. VMAT plans don’t improve whole breast dose uniformity as compared that to the tangential plans. Conclusion: The presence of transverse magnetic field in MRI-guided RT delivery for whole breast irradiation can Result in slightly improved dose homogeneity in the whole breast, increased dose to the ipsilateral lung, heart, and skin. Plan optimization with additional specific dose volume constraints may eliminate/reduce these dose increases. This work is partially supported by Elekta Inc.

  9. Radiation synthesis of stimuli-responsive hydrogels and the application to intelligent drug delivery systems

    International Nuclear Information System (INIS)

    Radiation-prepared synthetic and natural polyelectrolyte and polyampholite hydrogels were applied to the intelligent drug delivery systems (DDS). The intelligent membranes and chips were prepared by nano-porous fabrication with Eximalaser and ion-beam irradiations and the coating of stimuli-responsive hydrogels. This coating was efficiently carried out by curing processing with conveyer system. Computer programming control of intelligent drug releases was studied for the design of DDS chips to carry out the multiple drug delivery in response to multiple environmental changes. (author)

  10. Direct Plan Comparison of RapidArc and CyberKnife for Spine Stereotactic Body Radiation Therapy

    CERN Document Server

    Choi, Young Eun; Song, Si Yeol; Choi, Eun Kyung; Ahn, Seung Do; Cho, Byungchul

    2015-01-01

    We compared the treatment planning performance of RapidArc (RA) vs. CyberKnife (CK) for spinal stereotactic body radiation therapy (SBRT). Ten patients with spinal lesions who had been treated with CK were re-planned with RA, which consisted of two complete arcs. Computed tomography (CT) and volumetric dose data of CK, generated using the Multiplan (Accuray) treatment planning system (TPS) and the Ray-Trace algorithm, were imported to Varian Eclipse TPS in Dicom format, and the data were compared with the RA plan using analytical anisotropic algorithm (AAA) dose calculation. The optimized dose priorities for both CK and RA plans were similar for all patients. The highest priority was to provide enough dose coverage to the planned target volume (PTV) while limiting the maximum dose to the spinal cord. Plan quality was evaluated with respect to PTV coverage, conformity index (CI), high-dose spillage, intermediate-dose spillage (R50% and D2cm), and maximum dose to the spinal cord, which are criteria recommended ...

  11. Intensity-modulated radiation therapy for pancreatic and prostate cancer using pulsed low–dose rate delivery techniques

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jie; Lang, Jinyi; Wang, Pei; Kang, Shengwei [Department of Radiation Oncology, Sichuan Cancer Hospital, Chengdu (China); Lin, Mu-han; Chen, Xiaoming [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Chen, Fu; Guo, Ming [Department of Radiation Oncology, Eye Ear Nose and Throat Hospital of Fudan University, Shanghai (China); Chen, Lili [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Ma, Chang-Ming Charlie, E-mail: charlie.ma@fccc.edu [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States)

    2014-01-01

    Reirradiation of patients who were previously treated with radiotherapy is vastly challenging. Pulsed low–dose rate (PLDR) external beam radiotherapy has the potential to reduce normal tissue toxicities while providing significant tumor control for recurrent cancers. This work investigates treatment planning techniques for intensity-modulated radiation therapy (IMRT)-based PLDR treatment of various sites, including cases with pancreatic and prostate cancer. A total of 20 patients with clinical recurrence were selected for this study, including 10 cases with pancreatic cancer and 10 with prostate cancer. Large variations in the target volume were included to test the ability of IMRT using the existing treatment planning system and optimization algorithm to deliver uniform doses in individual gantry angles/fields for PLDR treatments. Treatment plans were generated with 10 gantry angles using the step-and-shoot IMRT delivery technique, which can be delivered in 3-minute intervals to achieve an effective low dose rate of 6.7 cGy/min. Instead of dose constraints on critical structures, ring structures were mainly used in PLDR-IMRT optimization. In this study, the PLDR-IMRT plans were compared with the PLDR-3-dimensional conformal radiation therapy (3DCRT) plans and the PLDR-RapidArc plans. For the 10 cases with pancreatic cancer that were investigated, the mean planning target volume (PTV) dose for each gantry angle in the PLDR-IMRT plans ranged from 17.6 to 22.4 cGy. The maximum doses ranged between 22.9 and 34.8 cGy. The minimum doses ranged from 8.2 to 17.5 cGy. For the 10 cases with prostate cancer that were investigated, the mean PTV doses for individual gantry angles ranged from 18.8 to 22.6 cGy. The maximum doses per gantry angle were between 24.0 and 34.7 cGy. The minimum doses per gantry angle ranged from 4.4 to 17.4 cGy. A significant reduction in the organ at risk (OAR) dose was observed with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT

  12. Radiation dose in radiotherapy from prescription to delivery

    International Nuclear Information System (INIS)

    It is a known fact that an increasing percentage of the population in developed as well as developing countries contract cancer. However, in some advanced countries the cancer mortality rate is no longer increasing, which can be attributed to an improvement in therapy. In some developing countries radiation therapy is currently applied in 50-60% of all cancer cases. About half of these treatments are with curative aims. Surgery and radiotherapy applied individually or concurrently result in the cure of about 40-50% of all patients. In addition, the application of chemotherapy has curative effects on small percentage of cancer cases. Radiotherapy is also an excellent palliative agent and often prolongs and enhances the quality of life of a patient. In some countries, resources are too scarce to secure adequate treatments. When this happens, it is of great importance that they learn to utilize the available resources in the most effective way. One of the aims of this seminar is to deal with this issue. Refs, figs and tabs

  13. WE-D-BRD-01: Innovation in Radiation Therapy Delivery: Advanced Digital Linac Features

    Energy Technology Data Exchange (ETDEWEB)

    Xing, L [Stanford University, Stanford, CA (United States); Wong, J [Johns Hopkins University, Baltimore, MD (United States); Li, R [Stanford University, Palo Alto, CA (United States)

    2014-06-15

    Last few years has witnessed significant advances in linac technology and therapeutic dose delivery method. Digital linacs equipped with high dose rate FFF beams have been clinically implemented in a number of hospitals. Gated VMAT is becoming increasingly popular in treating tumors affected by respiratory motion. This session is devoted to update the audience with these technical advances and to present our experience in clinically implementing the new linacs and dose delivery methods. Topics to be covered include, technical features of new generation of linacs from different vendors, dosimetric characteristics and clinical need for FFF-beam based IMRT and VMAT, respiration-gated VMAT, the concept and implementation of station parameter optimized radiation therapy (SPORT), beam level imaging and onboard image guidance tools. Emphasis will be on providing fundamental understanding of the new treatment delivery and image guidance strategies, control systems, and the associated dosimetric characteristics. Commissioning and acceptance experience on these new treatment delivery technologies will be reported. Clinical experience and challenges encountered during the process of implementation of the new treatment techniques and future applications of the systems will also be highlighted. Learning Objectives: Present background knowledge of emerging digital linacs and summarize their key geometric and dosimetric features. SPORT as an emerging radiation therapy modality specifically designed to take advantage of digital linacs. Discuss issues related to the acceptance and commissioning of the digital linacs and FFF beams. Describe clinical utility of the new generation of digital linacs and their future applications.

  14. Gene therapy delivery of endostatin enhances the treatment efficacy of radiation

    International Nuclear Information System (INIS)

    Background and purpose: To evaluate whether sustained expression of mouse endostatin by adeno-associated virus (AAV)-mediated gene transfer can enhance the treatment efficacy of ionizing radiation. Materials and methods: Mouse endostatin was cloned into recombinant AAV (rAAV) under the control of CMV β-actin promoter. Recombinant mouse endostatin expressed via AAV gene transfer was tested for biological activity in endothelial cells. The impact of elevated serum levels of endostatin on tumor-induced angiogenesis was evaluated using an in vivo angiogenesis assay. The anti-tumor efficacy of combining rAAV-mediated endostatin delivery with radiation was evaluated in a human colorectal tumor model (HT29). Results: Recombinant mouse endostatin expressed through an AAV vector (rAAV-mEndo) inhibited endothelial cell proliferation (by 40-45%) and migration (by 22-33%). Intramuscular injection of rAAV-mEndo (1x109 i.u.) led to a sustained serum endostatin level of ∼500 ng/ml. Compared to control animals this endostatin level was sufficient to inhibit tumor cell-induced vessel formation (37 vs. 28.5, P3, 21 vs. 34.5 days, P3 (radiation, 34 days; endostatin plus radiation, 50 days, P<0.05). Conclusion: The delivery of endostatin via rAAV vectors may provide an effective means of enhancing the anti-tumor efficacy of radiation therapy

  15. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, David, E-mail: d-pasquier@o-lambret.fr [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Centre Galilee, Clinique de la Louviere, Lille (France); Cavillon, Fabrice [Universite Lille Nord de France, Lille (France); Faculte Libre de Medecine, Lille (France); Lacornerie, Thomas [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Touzeau, Claire [Centre Galilee, Clinique de la Louviere, Lille (France); Tresch, Emmanuelle [Unite de Methodologie et Biostatistique, Centre O. Lambret, Lille (France); Lartigau, Eric [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France)

    2013-02-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  16. Delivery of 3-5 μm laser radiation by a hollow waveguide

    Science.gov (United States)

    Němec, M.; Jelínková, H.; Miyagi, M.; Iwai, K.; Doroshenko, M.

    2014-04-01

    Radiation delivery is required for various applications—mainly in medicine or industry. Due to the necessity of delivering IR, UV or powerful radiation, its transfer by hollow waveguides was investigated because standard glass fibers cause serious losses. Our special waveguide was based on a fused silica glass capillary tube with an inner silver layer and dielectric film (cyclic olefin polymer (COP)). Three lasers were designed and constructed as mid-infrared sources, namely Er:YAG (2.94 μm), Dy: PbGa2S4 (4.3 μm) and Fe:ZnSe (4.45 μm). The delivered spatial beam profile and transfer capability of 3-5 μm radiation by the COP/Ag hollow glass waveguide were characterized.

  17. Polymer matrices obtained by ionizing radiation for using in controlled drug delivery systems

    International Nuclear Information System (INIS)

    Two kinds of controlled drug delivery system were obtained by gamma radiation induced polymerization. One of the system was obtained from an acrylic derivative of acetaminophen (40-hydroxyacetanilide), by copolymerization of 4-(acryloyloxy) acetanilide and N,N-dimethylacrylamide (DMAA) in dimethylformamide solution with 0,16 kGy/h dose rate and 54 Gy dose. The values of reactivity rate, r-DMAA = 0,31 ± 0,02 e rAOA -0,07 ± 0,12, were determined by Fineman-Ross method. The acetaminophen hydrolysis was carried out in alkaline and enzymatic (trypsin) media. Another kind of drug delivery system studied was solvent controlled type, being the drug immobilized in the hydrogel,. The hydrogels prepared by radiation polymerization of acryloyl-L-propine methylester (A-Pro-OMe) with 10 Gy dose, showed thermosensible property, swelling or shrinking in water with decreased or increased temperatures. The hydrogels were obtained with different crosslink density, trimethylolpropane trimethacrylate, and the monomers N, N-dimethyl acrylamide (DMAA) and 2-cyanoethyl acrylate to study the influence of the composition in the drug delivery rate. It was verified that the porous size besides being a characteristic of the matrix composition, it was also temperature dependent (thermosensible). The analgesic drug acetaminophen was immobilized by entrapment and by physical adsorption into the hydrogels matrices for 'in vitro' study. The insulin was immobilized by adsorption for 'in vivo' study. (author)

  18. Comparison of rapidArc and fixed field intensity-modulated radiation therapies for advanced nasopharyngeal carcinoma%晚期鼻咽癌RapidArc与固定野调强放疗的比较研究

    Institute of Scientific and Technical Information of China (English)

    庄名赞; 张拓丹; 彭逊; 陈志坚; 林志雄; 李德锐

    2013-01-01

      目的:近年RapidArc的临床应用已引起越来越多的关注,本研究比较RapidArc与固定野调强放射治疗(IMRT)两种放疗技术在晚期鼻咽癌治疗计划中的差异.方法:随机选取10例晚期鼻咽癌患者,采用RapidArc与IMRT两种技术进行计划设计与剂量验证,比较计划的靶区剂量、危及器官与正常组织剂量、机器跳数、治疗时间与剂量验证结果.结果:两种计划的剂量分布基本一致,均能提供足够的靶区剂量.RapidArc的PTVnx最小剂量,PTVnd、PTV60、喉、腮腺的平均剂量低于IMRT,PTV60的HI值高于 IMRT,机器跳数比 IMRT 减少约58%,治疗时间减少约70%.以3%/3mm 为界,RapidArc 验证的γ指数通过率为(98.75±0.50)%,IMRT的通过率为(98.86±0.67)%.结论:两种放疗技术均能够满足临床治疗需要,剂量验证结果能够较好的符合计划计算结果.RapidArc比IMRT有着更多的优势,不仅可以减少机器跳数,缩短治疗时间,而且可以减少喉、腮腺的受照剂量.%Objective: This study compares volumetric-modulated arc therapy (RapidArc) and fixed field intensity-modulated radiation therapy (IMRT) for advanced nasopharyngeal carcinoma. Methods: Ten advanced nasopharyngeal carcinoma patients were randomly selected for this study. Two treatment plans were completed for each patient, i.e., the RapidArc and IMRT schemes. Dosimetric verification was conducted for each scheme. The doses for the planning target volumes (PTVs), organs at risk (OARs), and normal tissues were compared. The technical delivery parameters, including monitor units (MUs), time of therapy, and results of dosimetric verification, were analyzed. Results: No significant differences were found in dose distribution between the two schemes. Both techniques delivered adequate doses for the PTVs. For RapidArc planning, the minimal dose of PTVnx, mean dose of PTVnd, PTV60, larynx, and parotid were lower compared with those of IMRT schemes, whereas the

  19. The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery

    DEFF Research Database (Denmark)

    Falk, Marianne; Larsson, Tobias; Keall, P.;

    2012-01-01

    parameters did not depend significantly on the LPC (p ≥ 0.066), whereas the ALD depended significantly on the LPC (p gamma index failure rate depended significantly on the ALD, weighted to the percentage of the beam delivered in each control point of the plan (ALDw) when MLC tracking was used...... with a single 358° arc were generated with LPC priorities of 0 (no LPC), 0.25, 0.5, 0.75, and 1 (highest possible LPC), respectively. All the plans had a prescribed dose of 2 Gy × 30, used 6 MV, a maximum dose rate of 600 MU/min and a collimator angle of 45° or 315°. To quantify the plan modulation, an average...... adjacent leaf distance (ALD) was calculated by averaging the mean adjacent leaf distance for each control point. The linear relationship between the plan quality [i.e., the calculated dose distributions and the number of monitor units (MU)] and the LPC was investigated, and the linear regression...

  20. SU-E-T-624: Quantitative Evaluation of 2D Versus 3D Dosimetry for Stereotactic Volumetric Modulated Arc Delivery Using COMPASS

    Energy Technology Data Exchange (ETDEWEB)

    Vikraman, S; Karrthick, K; Rajesh, T; Sambasivaselli, R; Senniandanvar, V; Kataria, T [Medanta The Medicity, Gurgaon, Haryana (India); Manigandan, D [Sri Siddhivinayak Ganapathi Cancer hospital, Miraj, Maharastra (India); Karthikeyan, N [St Johns Medical College, Bangalore, Karnataka (India); Muthukumaran, M [Apollo Super Speciality Hospital, Chennai, Tamil Nadu (India)

    2014-06-15

    Purpose: The purpose of this study was to evaluate quantitatively 2D versus 3D dosimetry for stereotactic volumetric modulated arc delivery using COMPASS with 2D array. Methods: Twenty-five patients CT images and RT structures of different sites like brain, head and neck, thorax, abdomen and spine were taken from Multiplan planning system for this study. All these patients underwent radical stereotactic treatment in Cyberknife. For each patient, linac based VMAT stereotactic plans were generated in Monaco TPS v 3.1 using Elekta Beam Modulator MLC. Dose prescription was in the range of 5-20Gy/fraction.TPS calculated VMAT plan delivery accuracy was quantitatively evaluated with COMPASS measured dose and calculated dose based on DVH metrics. In order to ascertain the potential of COMPASS 3D dosimetry for stereotactic plan delivery, 2D fluence verification was performed with MatriXX using Multicube. Results: For each site, D{sub 9} {sub 5} was achieved with 100% of prescription dose with maximum 0.05SD. Conformity index (CI) was observed closer to 1.15 in all cases. Maximum deviation of 2.62 % was observed for D{sub 9} {sub 5} when compared TPS versus COMPASS measured. Considerable deviations were observed in head and neck cases compare to other sites. The maximum mean and standard deviation for D{sub 9} {sub 5}, average target dose and average gamma were -0.78±1.72, -1.10±1.373 and 0.39±0.086 respectively. Numbers of pixels passing 2D fluence verification were observed as a mean of 99.36% ±0.455 SD with 3% dose difference and 3mm DTA. For critical organs in head and neck cases, significant dose differences were observed in 3D dosimetry while the target doses were matched well within limit in both 2D and 3D dosimetry. Conclusion: The quantitative evaluations of 2D versus 3D dosimetry for stereotactic volumetric modulated plans showed the potential of highlighting the delivery errors. This study reveals that COMPASS 3D dosimetry is an effective tool for patient

  1. Drug delivery observation of hydrophobe ferrofluid and magnetite nanoparticals by SPring-8 synchrotron radiation.

    Science.gov (United States)

    Ju, D Y; Bian, P; Kumazawa, T; Nakano, M; Matsuura, H; Umetani, K; Komdo, T; Uozumi, Y; Makino, K; Noda, N; Koide, K; Akutsu, M; Masuyama, K

    2011-10-01

    In this study, the composite magnetic nanoparticles of coated SiO nano film with about 8 nm size and high saturation magnetization value, were synthesized by liquid phase precipitation method. The magnetic nanoparticles can be dispersed in various liquid media, widely known as magnetic fluids or ferrofluids with both magnetic and liquid properties. The materials been collected great interests and more and more attentions to focus into Drug Delivery System (DDS) as a new technology in this paper. We use the composite nanoparticles to disperse H2O and inject the solutions into rat's in-vivo organs. And, in the experiments by using a strong photon beam of SPring-8 Synchrotron Radiation facility, the distribution stat and the effects of magnetic field as well as drug delivery behaviour of nanoparticles in the rat' kidney are verified by the in-vivo observations. PMID:22400252

  2. Preparation and Characterization of Bragg Fibers for Delivery of Laser Radiation at 1064 nm

    Directory of Open Access Journals (Sweden)

    V. Matejec

    2013-04-01

    Full Text Available Bragg fibers offer new performance for transmission of high laser energies over long distances. In this paper theoretical modeling, preparation and characterization of Bragg fibers for delivery laser radiation at 1064 nm are presented. Investigated Bragg fibers consist of the fiber core with a refractive index equal to that of silica which is surrounded by three pairs of circular layers. Each pair is composed of one layer with a high and one layer with a low refractive index and characterized by a refractive-index difference around 0.03. Propagation constants and radiation losses of the fundamental mode in such a structure were calculated on the basis of waveguide optics. Preforms of the Bragg fibers were prepared by the MCVD method using germanium dioxide, phosphorous pentoxide and fluorine as silica dopants. The fibers with a diameter of 170 m were drawn from the preforms. Refractive-index profiles, angular distributions of the output power and optical losses of the prepared fibers were measured. Results of testing the fibers for delivery radiation of a pulse Nd:YAG laser at 1064 nm are also shown.

  3. Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring.

    Science.gov (United States)

    Parodi, Katia

    2015-12-01

    Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy

  4. Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Parodi, Katia, E-mail: Katia.parodi@physik.uni-muenchen.de [Faculty of Physics, Department of Medical Physics, Ludwig Maximilians University Munich, Munich 85748 (Germany)

    2015-12-15

    Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy

  5. Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Rachit; Wild, Aaron T.; Ziegler, Mark A.; Hooker, Ted K.; Dah, Samson D.; Tran, Phuoc T.; Kang, Jun; Smith, Koren; Zeng, Jing [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Pawlik, Timothy M. [Department of Surgery, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Ford, Eric [Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Seattle, WA (United States); Herman, Joseph M., E-mail: jherma15@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States)

    2013-10-01

    Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at

  6. Dosimetric Comparison of Volumetric Modulated Arc Therapy, Static Field Intensity Modulated Radiation Therapy, and 3D Conformal Planning for the Treatment of a Right-Sided Reconstructed Chest Wall and Regional Nodal Case

    Directory of Open Access Journals (Sweden)

    Vishruta A. Dumane

    2014-01-01

    Full Text Available We compared 3D conformal planning, static field intensity modulated radiation therapy (IMRT, and volumetric modulated arc therapy (VMAT to investigate the suitable treatment plan and delivery method for a right-sided reconstructed chest wall and nodal case. The dose prescribed for the reconstructed chest wall and regional nodes was 50.4 Gy. Plans were compared for target coverage and doses of the lungs, heart, contralateral breast, and healthy tissue. All plans achieved acceptable coverage of the target and IMNs. The best right lung sparing achieved with 3D was a V20 Gy of 31.09%. Compared to it, VMAT reduced the same by 10.85% and improved the CI and HI over 3D by 18.75% and 2%, respectively. The ipsilateral lung V5 Gy to V20 Gy decreased with VMAT over IMRT by as high as 17.1%. The contralateral lung V5 Gy was also lowered with VMAT compared to IMRT by 16.22%. The MU and treatment beams were lowered with VMAT over IMRT by 30% and 10, respectively, decreasing the treatment time by >50%. VMAT was the treatment plan and delivery method of choice for this case due to a combination of improved lung sparing and reduced treatment time without compromising target coverage.

  7. Analysis of dose distribution in organs at risk in patients with prostate cancer treated with the intensity-modulated radiation therapy and arc technique.

    Science.gov (United States)

    Biegała, Michał; Hydzik, Adam

    2016-01-01

    This study describes a comparative analysis of treatment plans in 48 patients with prostate cancer treated with ionizing radiation. Each patient was subjected to the intensity-modulated radiation therapy (IMRT) and arc technique. In each treatment plan, the organs at risk were assessed: the urinary bladder, rectum and heads of the femur, as well as the volume of normal tissue. The following features were compared: treatment time, conformity indices for the planning target volume, mean doses and standard deviation in organs at risk, and organ volumes for each particular dose. The treatment period in the arc technique is 13.7% shorter than in the IMRT technique. Comparing the results of the IMRT and arc techniques (arc vs. IMRT), the mean values were 29.21 ± 12.91 Gy versus 28.36 ± 13.79 Gy for the bladder, 20.36 ± 3.16 Gy versus 18.17 ± 5.11 Gy for the right femoral head, and 18.98 ± 3.28 Gy versus 16.67 ± 5.15 Gy for the left femoral head. For the rectum, lower values were obtained after application of the arc technique, not the IMRT technique: 35.84 ± 12.28 Gy versus 35.90 ± 13.05 Gy. The results indicate that the applied therapy has a statistically significant influence on the volume for a particular dose with regard to the urinary bladder. It is advisable to apply the IMRT technique to patients who need the femur heads and urinary bladder protected by exposing them to low irradiation doses. PMID:27651567

  8. Radiation dose delivery verification in the treatment of carcinoma-cervix

    Energy Technology Data Exchange (ETDEWEB)

    Shrotriya, D., E-mail: shrotriya2007@gmail.com; Srivastava, R. N. L. [Department of Radiotherapy, J.K. Cancer Institute Kanpur-208019 (India); Kumar, S. [Department of Physics, Christ Church College, Kanpur-208001 (India)

    2015-06-24

    The accurate dose delivery to the clinical target volume in radiotherapy can be affected by various pelvic tissues heterogeneities. An in-house heterogeneous woman pelvic phantom was designed and used to verify the consistency and computational capability of treatment planning system of radiation dose delivery in the treatment of cancer cervix. Oncentra 3D-TPS with collapsed cone convolution (CCC) dose calculation algorithm was used to generate AP/PA and box field technique plan. the radiation dose was delivered by Primus Linac (Siemens make) employing high energy 15 MV photon beam by isocenter technique. A PTW make, 0.125cc ionization chamber was used for direct measurements at various reference points in cervix, bladder and rectum. The study revealed that maximum variation between computed and measured dose at cervix reference point was 1% in both the techniques and 3% and 4% variation in AP/PA field and 5% and 4.5% in box technique at bladder and rectum points respectively.

  9. Radiation dose delivery verification in the treatment of carcinoma-cervix

    Science.gov (United States)

    Shrotriya, D.; Kumar, S.; Srivastava, R. N. L.

    2015-06-01

    The accurate dose delivery to the clinical target volume in radiotherapy can be affected by various pelvic tissues heterogeneities. An in-house heterogeneous woman pelvic phantom was designed and used to verify the consistency and computational capability of treatment planning system of radiation dose delivery in the treatment of cancer cervix. Oncentra 3D-TPS with collapsed cone convolution (CCC) dose calculation algorithm was used to generate AP/PA and box field technique plan. the radiation dose was delivered by Primus Linac (Siemens make) employing high energy 15 MV photon beam by isocenter technique. A PTW make, 0.125cc ionization chamber was used for direct measurements at various reference points in cervix, bladder and rectum. The study revealed that maximum variation between computed and measured dose at cervix reference point was 1% in both the techniques and 3% and 4% variation in AP/PA field and 5% and 4.5% in box technique at bladder and rectum points respectively.

  10. Prostate Stereotactic Ablative Radiation Therapy Using Volumetric Modulated Arc Therapy to Dominant Intraprostatic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Louise J. [Department of Clinical Oncology, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); University of Leeds, Leeds (United Kingdom); Lilley, John; Thompson, Christopher M.; Cosgrove, Vivian [Department of Medical Physics, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); Mason, Josh [Department of Medical Physics, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); University of Leeds, Leeds (United Kingdom); Sykes, Jonathan [Department of Medical Physics, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); Franks, Kevin [Department of Clinical Oncology, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); Sebag-Montefiore, David [Department of Clinical Oncology, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); University of Leeds, Leeds (United Kingdom); Henry, Ann M., E-mail: Ann.Henry@leedsth.nhs.uk [Department of Clinical Oncology, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom)

    2014-06-01

    Purpose: To investigate boosting dominant intraprostatic lesions (DILs) in the context of stereotactic ablative radiation therapy (SABR) and to examine the impact on tumor control probability (TCP) and normal tissue complication probability (NTCP). Methods and Materials: Ten prostate datasets were selected. DILs were defined using T2-weighted, dynamic contrast-enhanced and diffusion-weighted magnetic resonance imaging. Four plans were produced for each dataset: (1) no boost to DILs; (2) boost to DILs, no seminal vesicles in prescription; (3) boost to DILs, proximal seminal vesicles (proxSV) prescribed intermediate dose; and (4) boost to DILs, proxSV prescribed higher dose. The prostate planning target volume (PTV) prescription was 42.7 Gy in 7 fractions. DILs were initially prescribed 115% of the PTV{sub Prostate} prescription, and PTV{sub DIL} prescriptions were increased in 5% increments until organ-at-risk constraints were reached. TCP and NTCP calculations used the LQ-Poisson Marsden, and Lyman-Kutcher-Burman models respectively. Results: When treating the prostate alone, the median PTV{sub DIL} prescription was 125% (range: 110%-140%) of the PTV{sub Prostate} prescription. Median PTV{sub DIL} D50% was 55.1 Gy (range: 49.6-62.6 Gy). The same PTV{sub DIL} prescriptions and similar PTV{sub DIL} median doses were possible when including the proxSV within the prescription. TCP depended on prostate α/β ratio and was highest with an α/β ratio = 1.5 Gy, where the additional TCP benefit of DIL boosting was least. Rectal NTCP increased with DIL boosting and was considered unacceptably high in 5 cases, which, when replanned with an emphasis on reducing maximum dose to 0.5 cm{sup 3} of rectum (Dmax{sub 0.5cc}), as well as meeting existing constraints, resulted in considerable rectal NTCP reductions. Conclusions: Boosting DILs in the context of SABR is technically feasible but should be approached with caution. If this therapy is adopted, strict rectal

  11. The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targets

    Energy Technology Data Exchange (ETDEWEB)

    Roa, Dante E., E-mail: droa@uci.edu [Department of Radiation Oncology, Chao Family Comprehensive Cancer Center, University of California, Irvine-Medical Center, Orange, CA (United States); Schiffner, Daniel C.; Zhang Juying; Dietrich, Salam N.; Kuo, Jeffrey V.; Wong, Jason; Ramsinghani, Nilam S.; Al-Ghazi, Muthana S.A.L. [Department of Radiation Oncology, Chao Family Comprehensive Cancer Center, University of California, Irvine-Medical Center, Orange, CA (United States)

    2012-10-01

    Twenty-three targets in 16 patients treated with stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT) were analyzed in terms of dosimetric homogeneity, target conformity, organ-at-risk (OAR) sparing, monitor unit (MU) usage, and beam-on time per fraction using RapidArc volumetric-modulated arc therapy (VMAT) vs. multifield sliding-window intensity-modulated radiation therapy (IMRT). Patients underwent computed tomography simulation with site-specific immobilization. Magnetic resonance imaging fusion and optical tracking were incorporated as clinically indicated. Treatment planning was performed using Eclipse v8.6 to generate sliding-window IMRT and 1-arc and 2-arc RapidArc plans. Dosimetric parameters used for target analysis were RTOG conformity index (CI{sub RTOG}), homogeneity index (HI{sub RTOG}), inverse Paddick Conformity Index (PCI), D{sub mean} and D5-D95. OAR sparing was analyzed in terms of D{sub max} and D{sub mean}. Treatment delivery was evaluated based on measured beam-on times delivered on a Varian Trilogy linear accelerator and recorded MU values. Dosimetric conformity, homogeneity, and OAR sparing were comparable between IMRT, 1-arc RapidArc and 2-arc RapidArc plans. Mean beam-on times {+-} SD for IMRT and 1-arc and 2-arc treatments were 10.5 {+-} 7.3, 2.6 {+-} 1.6, and 3.0 {+-} 1.1 minutes, respectively. Mean MUs were 3041, 1774, and 1676 for IMRT, 1-, and 2-arc plans, respectively. Although dosimetric conformity, homogeneity, and OAR sparing were similar between these techniques, SRS and SBRT fractions treated with RapidArc were delivered with substantially less beam-on time and fewer MUs than IMRT. The rapid delivery of SRS and SBRT with RapidArc improved workflow on the linac with these otherwise time-consuming treatments and limited the potential for intrafraction organ and patient motion, which can cause significant dosimetric errors. These clinically important advantages make image-guided RapidArc useful in the delivery

  12. Dosimetric comparison of intensity modulated radiation, Proton beam therapy and proton arc therapy for para-aortic lymph node tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon [Dept. of Radiation Oncology, Konyang University Hospital. Daejeon (Korea, Republic of)

    2014-12-15

    To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, D{sub 30%}, D{sub 60%}, D{sub 90%}, V{sub 30%}, V{sub 60%}, V{sub 90}%, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

  13. Locally Targeted Delivery of a Micron-Size Radiation Therapy Source Using Temperature-Sensitive Hydrogel

    International Nuclear Information System (INIS)

    Purpose: To propose a novel radiation therapy (RT) delivery modality: locally targeted delivery of micron-size RT sources by using temperature-sensitive hydrogel (RT-GEL) as an injectable vehicle. Methods and Materials: Hydrogel is a water-like liquid at room temperature but gels at body temperature. Two US Food and Drug Administration-approved polymers were synthesized. Indium-111 (In-111) was used as the radioactive RT-GEL source. The release characteristics of In-111 from polymerized RT-GEL were evaluated. The injectability and efficacy of RT-GEL delivery to human breast tumor were tested using animal models with control datasets of RT-saline injection. As proof-of-concept studies, a total of 6 nude mice were tested by injecting 4 million tumor cells into their upper backs after a week of acclimatization. Three mice were injected with RT-GEL and 3 with RT-saline. Single-photon emission computed tomography (SPECT) and CT scans were performed on each mouse at 0, 24, and 48 h after injection. The efficacy of RT-GEL was determined by comparison with that of the control datasets by measuring kidney In-111 accumulation (mean nCi/cc), representing the distant diffusion of In-111. Results: RT-GEL was successfully injected into the tumor by using a 30-gauge needle. No difficulties due to polymerization of hydrogel during injection and intratumoral pressure were observed during RT-GEL injection. No back flow occurred for either RT-GEL or RT-saline. The residual tumor activities of In-111 were 49% at 24 h (44% at 48 h, respectively) for RT-GEL and 29% (22%, respectively) for RT-saline. Fused SPECT-CT images of RT-saline showed considerable kidney accumulation of In-111 (2886%, 261%, and 262% of RT-GEL at 0, 24, and 48 h, respectively). Conclusions: RT-GEL was successfully injected and showed much higher residual tumor activity: 170% (200%, respectively), than that of RT-saline at 24 h (48 h, respectively) after injection with a minimal accumulation of In-111 to the

  14. SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

    International Nuclear Information System (INIS)

    Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field

  15. Failure Mode and Effect Analysis for Delivery of Lung Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Purpose: To improve the quality and safety of our practice of stereotactic body radiation therapy (SBRT), we analyzed the process following the failure mode and effects analysis (FMEA) method. Methods: The FMEA was performed by a multidisciplinary team. For each step in the SBRT delivery process, a potential failure occurrence was derived and three factors were assessed: the probability of each occurrence, the severity if the event occurs, and the probability of detection by the treatment team. A rank of 1 to 10 was assigned to each factor, and then the multiplied ranks yielded the relative risks (risk priority numbers). The failure modes with the highest risk priority numbers were then considered to implement process improvement measures. Results: A total of 28 occurrences were derived, of which nine events scored with significantly high risk priority numbers. The risk priority numbers of the highest ranked events ranged from 20 to 80. These included transcription errors of the stereotactic coordinates and machine failures. Conclusion: Several areas of our SBRT delivery were reconsidered in terms of process improvement, and safety measures, including treatment checklists and a surgical time-out, were added for our practice of gantry-based image-guided SBRT. This study serves as a guide for other users of SBRT to perform FMEA of their own practice.

  16. Organisational standards for the delivery of intensity-modulated radiation therapy in Ontario.

    Science.gov (United States)

    Whitton, A; Warde, P; Sharpe, M; Oliver, T K; Bak, K; Leszczynski, K; Etheridge, S; Fleming, K; Gutierrez, E; Favell, L; Green, E

    2009-04-01

    By minimising the effect of irradiation on surrounding tissue, intensity-modulated radiation therapy (IMRT) can deliver higher, more effective doses to the targeted tumour site, minimising treatment-related morbidity and possibly improving cancer control and cure. A multidisciplinary IMRT Expert Panel was convened to develop the organisational standards for the delivery of IMRT. The systematic literature search used MEDLINE, EMBASE, the Cochrane Database, the National Guidelines Clearing House and the Health Technology Assessment Database. An environmental scan of unpublished literature used the Google search engine to review the websites of key organisations, cancer agencies/centres and vendor sites in Canada, the USA, Australia and Europe. In total, 22 relevant guidance documents were identified; 12 from the published literature and 10 from the environmental scan. Professional and organisational standards for the provision of IMRT were developed through the analysis of this evidence and the consensus opinion of the IMRT Expert Panel. The resulting standards address the following domains: planning of new IMRT programmes, practice setting requirements, tools, devices and equipment requirements; professional training requirements; role of personnel; and requirements for quality assurance and safety. Here the IMRT Expert Panel offers organisational and professional standards for the delivery of IMRT, with the intent of promoting innovation, improving access and enhancing patient care.

  17. Treatment planning study comparing proton therapy, RapidArc and intensity modulated radiation therapy for a synchronous bilateral lung cancer case

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-03-01

    Full Text Available Purpose: The main purpose of this study is to perform a treatment planning study on a synchronous bilateral non-small cell lung cancer case using three treatment modalities: uniform scanning proton therapy, RapidArc, and intensity modulated radiation therapy (IMRT. Methods: The maximum intensity projection (MIP images obtained from the 4 dimensional-computed tomography (4DCT scans were used for delineation of tumor volumes in the left and right lungs. The average 4D-CT was used for the treatment planning among all three modalities with identical patient contouring and treatment planning goal. A proton therapy plan was generated in XiO treatment planning system (TPS using 2 fields for each target. For a comparative purpose, IMRT and RapidArc plans were generated in Eclipse TPS. Treatment plans were generated for a total dose of 74 CGE or Gy prescribed to each planning target volume (PTV (left and right with 2 CGE or Gy per fraction. In IMRT and RapidArc plans, normalization was done based on PTV coverage values in proton plans. Results: The mean PTV dose deviation from the prescription dose was lower in proton plan (within 3.4%, but higher in IMRT (6.5% to 11.3% and RapidArc (3.8% to 11.5% plans. Proton therapy produced lower mean dose to the total lung, heart, and esophagus when compared to IMRT and RapidArc. The relative volume of the total lung receiving 20, 10, and 5 CGE or Gy (V20, V10, and V5, respectively were lower using proton therapy than using IMRT, with absolute differences of 9.71%, 22.88%, and 39.04%, respectively. The absolute differences in the V20, V10, and V5 between proton and RapidArc plans were 4.84%, 19.16%, and 36.8%, respectively, with proton therapy producing lower dosimetric values. Conclusion: Based on the results presented in this case study, uniform scanning proton therapy has a dosimetric advantage over both IMRT and RapidArc for a synchronous bi-lateral NSCLC, especially for the normal lung tissue, heart, and

  18. Treatment planning study comparing proton therapy, RapidArc and intensity modulated radiation therapy for a synchronous bilateral lung cancer case

    OpenAIRE

    Suresh Rana; Shyam Pokharel; Yuanshui Zheng; Li Zhao; Dina Risalvato; Carlos Vargas; Nancy Cersonsky

    2014-01-01

    Purpose: The main purpose of this study is to perform a treatment planning study on a synchronous bilateral non-small cell lung cancer case using three treatment modalities: uniform scanning proton therapy, RapidArc, and intensity modulated radiation therapy (IMRT). Methods: The maximum intensity projection (MIP) images obtained from the 4 dimensional-computed tomography (4DCT) scans were used for delineation of tumor volumes in the left and right lungs. The average 4D-CT was used for the tre...

  19. The Impact of Advanced Technologies on Treatment Deviations in Radiation Treatment Delivery

    International Nuclear Information System (INIS)

    Purpose: To assess the impact of new technologies on deviation rates in radiation therapy (RT). Methods and Materials: Treatment delivery deviations in RT were prospectively monitored during a time of technology upgrade. In January 2003, our department had three accelerators, none with 'modern' technologies (e.g., without multileaf collimators [MLC]). In 2003 to 2004, we upgraded to five new accelerators, four with MLC, and associated advanced capabilities. The deviation rates among patients treated on 'high-technology' versus 'low-technology' machines (defined as those with vs. without MLC) were compared over time using the two-tailed Fisher's exact test. Results: In 2003, there was no significant difference between the deviation rate in the 'high-technology' versus 'low-technology' groups (0.16% vs. 0.11%, p = 0.45). In 2005 to 2006, the deviation rate for the 'high-technology' groups was lower than the 'low-technology' (0.083% vs. 0.21%, p = 0.009). This difference was caused by a decline in deviations on the 'high-technology' machines over time (p = 0.053), as well as an unexpected trend toward an increase in deviations over time on the 'low-technology' machines (p = 0.15). Conclusions: Advances in RT delivery systems appear to reduce the rate of treatment deviations. Deviation rates on 'high-technology' machines with MLC decline over time, suggesting a learning curve after the introduction of new technologies. Associated with the adoption of 'high-technology' was an unexpected increase in the deviation rate with 'low-technology' approaches, which may reflect an over-reliance on tools inherent to 'high-technology' machines. With the introduction of new technologies, continued diligence is needed to ensure that staff remain proficient with 'low-technology' approaches

  20. Sci—Sat AM: Stereo — 03: Dosmetric evaluation of single versus multi-arc VMAT for lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Karan, T; Taremi, M; Comsa, D [Southlake Regional Health Centre, Newmarket, Ontario (Canada); Radiation Medicine Program, University of Toronto, Toronto, Ontatio (Canada); Allibhai, Z; Ryan, M; Le, K [Southlake Regional Health Centre, Newmarket, Ontario (Canada)

    2014-08-15

    Five non-small cell lung cancer patients previously treated with stereotactic body radiation therapy using the VMAT (volumetric modulated arc therapy) technique were selected for this retrospective study. Plans were re-optimized using Pinnacle treatment planning system (v9.0, Philips Medical), with the basis for comparison a two-arc plan involving a 360° arc in addition to a 90° arc with a couch kick. Additionally a single 360° arc was optimized for comparison, as well as a partial arc covering ∼230°, avoiding the contralateral lung. All plans met target coverage criteria as dictated by RTOG0236. Plans were evaluated based on conformity, sparing of organs at risk and practical considerations of delivery. Conformity was best in the two-arc plan; however the decrease seen in one- and partial arc plans was not statistically significant as tested by the Wilcoxon rank sum test. The partial-arc plan resulted in the lowest esophagus and trachea dose and the highest heart dose, however none of the plans exceeded organ at risk tolerances for lung SBRT. Partial arcs resulted in plans with slightly cooler dose distributions, a decrease in low dose spillage and an overall lower mean lung dose. The decrease in treatment time was on average 36 and 40 seconds for single and partial arcs, respectively, with partial arcs requiring the lowest number of MUs. The slight decrease in conformity seen in one-arc plans is offset by an increase in efficiency (optimization and treatment time, MUs) making the implementation of a single or partial-arc treatment technique clinically desirable.

  1. SU-E-T-248: Near Real-Time Analysis of Radiation Delivery and Imaging, Accuracy to Ensure Patient Safety

    Energy Technology Data Exchange (ETDEWEB)

    Wijesooriya, K; Seitter, K; Desai, V; Read, P; Larner, J [University of Virginia Health Systems, Charlottesville, VA (United States)

    2014-06-01

    Purpose: To develop and optimize an effective software method for comparing planned to delivered control point machine parameters for all VARIAN TrueBeam treatments so as to permit (1) assessment of a large patient pool throughout their treatment course to quantify treatment technique specific systematic and random uncertainty of observables, (2) quantify the site specific daily imaging shifts required for target alignment, and (3) define tolerance levels for mechanical parameters and imaging parameters based on statistical analysis data gathered, and the dosimetric impact of variations. Methods: Treatment and imaging log files were directly compared to plan parameters for Eclipse and Pinnacle planned treatments via 3D, IMRT, control point, RapidArc, and electrons. Each control point from all beams/arcs (7984) for all fractions (1940) of all patients treated over six months were analyzed. At each control point gantry angle, collimator angle, couch angle, jaw positions, MLC positions, MU were compared. Additionally per-treatment isocenter shifts were calculated. Results were analyzed as a whole in treatment type subsets: IMRT, 3D, RapidArc; and in treatment site subsets: brain, chest/mediastinum, esophagus, H and N, lung, pelvis, prostate. Results: Daily imaging isocenter shifts from initial external tattoo alignment were dependent on the treatment site with < 0.5 cm translational shifts for H and N, Brain, and lung SBRT, while pelvis, esophagus shifts were ∼1 cm. Mechanical delivery parameters were within tolerance levels for all sub-beams. The largest variations were for RapidArc plans: gantry angle 0.11±0.12,collimator angle 0.00±0.00, jaw positions 0.48±0.26, MLC leaf positions 0.66±0.08, MU 0.14±0.34. Conclusion: Per-control point validation reveals deviations between planned and delivered parameters. If used in a near real-time error checking system, patient safety can be improved by equipping the treatment delivery system with additional forcing

  2. Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial

    DEFF Research Database (Denmark)

    Colvill, Emma; Booth, Jeremy T; O'Brien, Ricky T;

    2015-01-01

    PURPOSE: To test the hypothesis that multileaf collimator (MLC) tracking improves the consistency between the planned and delivered dose compared with the dose without MLC tracking, in the setting of a prostate cancer volumetric modulated arc therapy trial. METHODS AND MATERIALS: Multileaf...... collimator tracking was implemented for 15 patients in a prostate cancer radiation therapy trial; in total, 513 treatment fractions were delivered. During each treatment fraction, the prostate trajectory and treatment MLC positions were collected. These data were used as input for dose reconstruction...

  3. A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer

    DEFF Research Database (Denmark)

    Gasic, Daniel; Ohlhues, Lars; Brodin, N. Patrik;

    2014-01-01

    plans with the same target dose coverage and doses to organs at risk as STD-VMAT plans. Target dose homogeneity tended to be somewhat inferior for FFF-VMAT for the larger targets......BACKGROUND: Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time...... compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that the treatment plan quality is comparable while the treatment delivery time of volumetric modulated arc therapy (VMAT) is considerably shorter using FFF beams, especially for stereotactic treatments...

  4. Treatment planning for volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bedford, James L. [Joint Department of Physics, Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

    2009-11-15

    Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

  5. The geometric calibration of cone-beam imaging and delivery systems in radiation therapy

    CERN Document Server

    Matsinos, E; Kaissl, Wolfgang; Matsinos, Evangelos

    2006-01-01

    We propose a method to achieve the geometric calibration of cone-beam imaging and delivery systems in radiation therapy; our approach applies to devices where an X-ray source and a flat-panel detector, facing each other, move in circular orbits around the irradiated object. In order to extract the parameters of the geometry from the data, we use a light needle phantom which is easy to manufacture. A model with ten free parameters (spatial lengths and distortion angles) has been put forth to describe the geometry and the mechanical imperfections of the units being calibrated; a few additional parameters are introduced to account for residual effects (small effects which lie beyond our model). The values of the model parameters are determined from one complete scan of the needle phantom via a robust optimisation scheme. The application of this method to two sets of five counterclockwise (ccw) and five clockwise (cw) scans yielded consistent and reproducible results. A number of differences have been observed be...

  6. Impact of prolonged fraction dose-delivery time modeling intensity-modulated radiation therapy on hepatocellular carcinoma cell killing

    Institute of Scientific and Technical Information of China (English)

    Xiao-Kang Zheng; Long-Hua Chen; Xiao Yan; Hong-Mei Wang

    2005-01-01

    AIM: To explore the impact of prolonged fraction dosedelivery time modeling intensity-modulated radiation therapy (IMRT) on cell killing of human hepatocellular carcinoma (HCC) HepG2 and Hep3B cell lines.METHODS: The radiobiological characteristics of human HCC HepG2 and Hep3b cell lines were studied with standard clonogenic assays, using standard linear-quadratic model and incomplete repair model to fit the dose-survival curves. The identical methods were also employed to investigate the biological effectiveness of irradiation protocols modeling clinical conventional fractionated external beam radiotherapy (EBRT, fraction delivery time 3 min) and IMRT with different prolonged fraction delivery time (15, 30, and 45 min). The differences of cell surviving fraction irradiated with different fraction delivery time were tested with paired t-test. Factors determining the impact of prolonged fraction delivery time on cell killing were analyzed.RESULTS: The α/β and repair half-time (T1/2) of HepG2and Hep3b were 3.1 and 7.4 Gy, and 22 and 19 min respectively. The surviving fraction of HepG2 irradiated modeling IMRT with different fraction delivery time was significantly higher than irradiated modeling EBRT and the cell survival increased more pronouncedly with the fraction delivery time prolonged from 15 to 45 min,while no significant differences of cell survival in Hep3b were found between different fraction delivery time protocols.CONCLUSION: The prolonged fraction delivery time modeling IMRT significantly decreased the cell killing in HepG2 but not in Hep3b. The capability of sub-lethal damage repair was the predominant factor determining the cell killing decrease. These effects, if confirmed by clinical studies, should be considered in designing IMRT treatments for HCC.

  7. Radiation-Guided Peptide Delivery in a Mouse Model of Nasopharyngeal Carcinoma

    Directory of Open Access Journals (Sweden)

    Pei-cheng Lin

    2016-01-01

    Full Text Available Purpose. This study aimed to evaluate the characteristics of the HVGGSSV peptide, exploring radiation-guided delivery in a mouse model of nasopharyngeal carcinoma. Methods. Mice with CNE-1 nasopharyngeal carcinoma were assigned to two different groups treated with Cy7-NHS and Cy7-HVGGSSV, respectively. Meanwhile, each mouse received a single dose of 3 Gy radiation. Biological distribution of the recombinant peptide was assessed on an in vivo small animal imaging system. Results. The experimental group showed maximum fluorescence intensity in irradiated tumors treated with Cy7-labeled HVGGSSV, while untreated (0 Gy control tumors showed lower intensity levels. Fluorescence intensities of tumors in the right hind limbs of experimental animals were 7.84×107±1.13×107, 1.35×108±2.66×107, 4.05×108±1.75×107, 5.57×108±3.47×107, and 9.26×107±1.73×107 photons/s/cm2 higher compared with left hind limb values at 1, 2, 15, 24, and 48 h, respectively. Fluorescence intensities of tumor in the right hind limbs of the experimental group were 1.66×108±1.71×107, 1.51×108±3.23×107, 5.38×108±1.96×107, 5.89×108±3.57×107, and 1.62×108±1.69×107 photons/s/cm2 higher compared with control group values at 1, 2, 15, 24, and 48 h, respectively. Fluorescence was not specifically distributed in the control group. Compared with low fluorescence intensity in the heart, lungs, and tumors, high fluorescence distribution was found in the liver and kidney at 48 h. Conclusions. HVGGSSV was selectively bound to irradiated nasopharyngeal carcinoma, acting as a targeting transport carrier for radiation-guided drugs that are mainly metabolized in the kidney and liver.

  8. Radiation-Guided Peptide Delivery in a Mouse Model of Nasopharyngeal Carcinoma

    Science.gov (United States)

    Lin, Pei-cheng; He, Jun-yan; Le, Yu-yin; Du, Kai-xin; Zhu, Wei-feng; Peng, Qing-qin; Dong, Ya-ping

    2016-01-01

    Purpose. This study aimed to evaluate the characteristics of the HVGGSSV peptide, exploring radiation-guided delivery in a mouse model of nasopharyngeal carcinoma. Methods. Mice with CNE-1 nasopharyngeal carcinoma were assigned to two different groups treated with Cy7-NHS and Cy7-HVGGSSV, respectively. Meanwhile, each mouse received a single dose of 3 Gy radiation. Biological distribution of the recombinant peptide was assessed on an in vivo small animal imaging system. Results. The experimental group showed maximum fluorescence intensity in irradiated tumors treated with Cy7-labeled HVGGSSV, while untreated (0 Gy) control tumors showed lower intensity levels. Fluorescence intensities of tumors in the right hind limbs of experimental animals were 7.84 × 107 ± 1.13 × 107, 1.35 × 108 ± 2.66 × 107, 4.05 × 108 ± 1.75 × 107, 5.57 × 108 ± 3.47 × 107, and 9.26 × 107 ± 1.73 × 107 photons/s/cm2 higher compared with left hind limb values at 1, 2, 15, 24, and 48 h, respectively. Fluorescence intensities of tumor in the right hind limbs of the experimental group were 1.66 × 108 ± 1.71 × 107, 1.51 × 108 ± 3.23 × 107, 5.38 × 108 ± 1.96 × 107, 5.89 × 108 ± 3.57 × 107, and 1.62 × 108 ± 1.69 × 107 photons/s/cm2 higher compared with control group values at 1, 2, 15, 24, and 48 h, respectively. Fluorescence was not specifically distributed in the control group. Compared with low fluorescence intensity in the heart, lungs, and tumors, high fluorescence distribution was found in the liver and kidney at 48 h. Conclusions. HVGGSSV was selectively bound to irradiated nasopharyngeal carcinoma, acting as a targeting transport carrier for radiation-guided drugs that are mainly metabolized in the kidney and liver.

  9. Pilot Study of the Delivery of Microcollimated Pars Plana External Beam Radiation in Porcine Eyes: 270-Day Analysis

    Directory of Open Access Journals (Sweden)

    Rishi P. Singh

    2012-01-01

    Full Text Available Objective. To determine the dose response and toxicity threshold of micro-collimated X-rays delivered to porcine maculae by a stereotactic radiosurgical system after 270 days. Methods. Twelve eyes of six Yucatan mini-swine were randomized to receive up to 90 Gy to the retina, using an office-based trans-pars plana delivery system. To determine the safety profile of this radiation delivery, ophthalmic examination, fundus photography, fluorescein angiography (FA, and spectral domain optical coherence tomography (SD-OCT were obtained at multiple time points up to 270 days post treatment. Results. No abnormalities were noted on external examination. Cataracts were noted in 4 of 12 eyes. Dose and time-dependent changes were noted on fundus examination, FA, ICG and SD-OCT. No significant abnormalities were seen in the control, 16 Gy or 24 Gy groups using any modality. Histopathology revealed a dose response effect with no discernable lesions in the 16 Gy group. Conclusion. The X-ray delivery system precisely targets the porcine retina in vivo with little effect on surrounding structures. No ophthalmic or intracranial adverse effects were noted at clinically relevant doses at 270 days following radiation delivery.

  10. Whole abdomen radiation therapy in ovarian cancers: a comparison between fixed beam and volumetric arc based intensity modulation

    Directory of Open Access Journals (Sweden)

    Clivio Alessandro

    2010-11-01

    Full Text Available Abstract Purpose A study was performed to assess dosimetric characteristics of volumetric modulated arcs (RapidArc, RA and fixed field intensity modulated therapy (IMRT for Whole Abdomen Radiotherapy (WAR after ovarian cancer. Methods and Materials Plans for IMRT and RA were optimised for 5 patients prescribing 25 Gy to the whole abdomen (PTV_WAR and 45 Gy to the pelvis and pelvic nodes (PTV_Pelvis with Simultaneous Integrated Boost (SIB technique. Plans were investigated for 6 MV (RA6, IMRT6 and 15 MV (RA15, IMRT15 photons. Objectives were: for both PTVs V90% > 95%, for PTV_Pelvis: Dmax Results IMRT and RapidArc resulted comparable for target coverage. For PTV_WAR, V90% was 99.8 ± 0.2% and 93.4 ± 7.3% for IMRT6 and IMRT15, and 98.4 ± 1.7 and 98.6 ± 0.9% for RA6 and RA15. Target coverage resulted improved for PTV_Pelvis. Dose homogeneity resulted slightly improved by RA (Uniformity was defined as U5-95% = D5%-D95%/Dmean. U5-95% for PTV_WAR was 0.34 ± 0.05 and 0.32 ± 0.06 (IMRT6 and IMRT15, 0.30 ± 0.03 and 0.26 ± 0.04 (RA6 and RA15; for PTV_Pelvis, it resulted equal to 0.1 for all techniques. For organs at risk, small differences were observed between the techniques. MU resulted 3130 ± 221 (IMRT6, 2841 ± 318 (IMRT15, 538 ± 29 (RA6, 635 ± 139 (RA15; the average measured treatment time was 18.0 ± 0.8 and 17.4 ± 2.2 minutes (IMRT6 and IMRT15 and 4.8 ± 0.2 (RA6 and RA15. GAIIMRT6 = 97.3 ± 2.6%, GAIIMRT15 = 94.4 ± 2.1%, GAIRA6 = 98.7 ± 1.0% and GAIRA15 = 95.7 ± 3.7%. Conclusion RapidArc showed to be a solution to WAR treatments offering good dosimetric features with significant logistic improvements compared to IMRT.

  11. Chronic exposure to the ultraviolet radiation levels from arc welding does not result in obvious damage to the human corneal endothelium.

    Science.gov (United States)

    Oblak, Emil; Doughty, Michael J

    2002-11-01

    Occupational exposure of the cornea to ultraviolet radiation (UVR, e.g. in welding) is a well-known cause of 'arc eye' (photo-keratoconjunctivitis), but has also been considered to be a risk for the development of alterations in the size (polymegethism) and shape (pleomorphism) of the deeper-lying human corneal endothelial cells. Human data are however limited and so a further study was undertaken, with a control group. Non-contact specular micrographs of the central region of the corneal endothelium were obtained from 40 white males aged between 32 and 63 years; 20 were arc welders with an average of 25 +/- 7 years job experience, while the others were office workers (n = 20). All the welders reported occupational exposure to UVR (i.e. welders 'flashes') and up to 3 times per year. None of the subjects had a history of contact lens wear, major eye disease or surgery. The endothelial image was scanned, projected onto an overlay and cell border marking carried out in a masked fashion. The overlay was independently analysed, by a customised semi-automated method, providing cell-border-adjusted data on cell areas and cell shape (sides) on 124 to 260 cells per image. The endothelial cell density (ECD) values were also calculated from individual cell area values. All corneas appeared to be healthy, and showed no fluorescein staining indicating damage to the surface epithelium. Central corneal thickness values were normal at 0.531 +/- 0.031 (mean +/- SD) and 0.527 +/- 0.036 mm in the welders and non-welders respectively. All endothelia appeared healthy, with no evidence of cell oedema. The group-mean endothelial cell area was 393 +/- 35 and 392 +/- 21 microm2, ECD values were 2855 +/- 224 cells mm(-2) and 2852 +/- 210 cells mm(-2), while the percentages of 6-sided cells were 60 +/- 5.2 and 59 +/- 4.1% respectively. Cell area distributions were statistically identical (p > or = 0.8), and cell area-side relationships were marginally, but not statistically different. This

  12. Arc Plasma Torch Modeling

    CERN Document Server

    Trelles, J P; Vardelle, A; Heberlein, J V R

    2013-01-01

    Arc plasma torches are the primary components of various industrial thermal plasma processes involving plasma spraying, metal cutting and welding, thermal plasma CVD, metal melting and remelting, waste treatment and gas production. They are relatively simple devices whose operation implies intricate thermal, chemical, electrical, and fluid dynamics phenomena. Modeling may be used as a means to better understand the physical processes involved in their operation. This paper presents an overview of the main aspects involved in the modeling of DC arc plasma torches: the mathematical models including thermodynamic and chemical non-equilibrium models, turbulent and radiative transport, thermodynamic and transport property calculation, boundary conditions and arc reattachment models. It focuses on the conventional plasma torches used for plasma spraying that include a hot-cathode and a nozzle anode.

  13. Welding arc radiation hazard and protection%电弧焊弧光幅射的危害与防护

    Institute of Scientific and Technical Information of China (English)

    欧泽兵

    2011-01-01

    在分析焊接产生的紫外线、可见光和红外线辐射特点及其危害的基础上,依据标准要求提出防护装备的使用要求以及通过培训以提高焊接操作者自我防护意识的建议,从而最大限度地减少焊接弧光对焊接操作者的危害.%The paper presents suggestion on welding hazards protection based on characteristics of UV.IR,visible lights and related standards.To minimize welding arc hazards via improving welders' safety consciousness by hazards analysis and protection training.

  14. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer.

    Science.gov (United States)

    Martin, Jeffrey M; Handorf, Elizabeth A; Price, Robert A; Cherian, George; Buyyounouski, Mark K; Chen, David Y; Kutikov, Alexander; Johnson, Matthew E; Ma, Chung-Ming Charlie; Horwitz, Eric M

    2015-01-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

  15. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Jeffrey M. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Handorf, Elizabeth A. [Department of Biostatistics, Fox Chase Cancer Center, Philadelphia, PA (United States); Price, Robert A.; Cherian, George [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Buyyounouski, Mark K. [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Chen, David Y.; Kutikov, Alexander [Department of Urologic Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Johnson, Matthew E.; Ma, Chung-Ming Charlie [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Horwitz, Eric M., E-mail: eric.horwitz@fccc.edu [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-10-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

  16. Adaptive Liver Stereotactic Body Radiation Therapy: Automated Daily Plan Reoptimization Prevents Dose Delivery Degradation Caused by Anatomy Deformations

    Energy Technology Data Exchange (ETDEWEB)

    Leinders, Suzanne M. [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Delft University of Technology, Delft (Netherlands); Breedveld, Sebastiaan; Méndez Romero, Alejandra [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Schaart, Dennis [Delft University of Technology, Delft (Netherlands); Seppenwoolde, Yvette, E-mail: y.seppenwoolde@erasmusmc.nl [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Heijmen, Ben J.M. [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands)

    2013-12-01

    Purpose: To investigate how dose distributions for liver stereotactic body radiation therapy (SBRT) can be improved by using automated, daily plan reoptimization to account for anatomy deformations, compared with setup corrections only. Methods and Materials: For 12 tumors, 3 strategies for dose delivery were simulated. In the first strategy, computed tomography scans made before each treatment fraction were used only for patient repositioning before dose delivery for correction of detected tumor setup errors. In adaptive second and third strategies, in addition to the isocenter shift, intensity modulated radiation therapy beam profiles were reoptimized or both intensity profiles and beam orientations were reoptimized, respectively. All optimizations were performed with a recently published algorithm for automated, multicriteria optimization of both beam profiles and beam angles. Results: In 6 of 12 cases, violations of organs at risk (ie, heart, stomach, kidney) constraints of 1 to 6 Gy in single fractions occurred in cases of tumor repositioning only. By using the adaptive strategies, these could be avoided (<1 Gy). For 1 case, this needed adaptation by slightly underdosing the planning target volume. For 2 cases with restricted tumor dose in the planning phase to avoid organ-at-risk constraint violations, fraction doses could be increased by 1 and 2 Gy because of more favorable anatomy. Daily reoptimization of both beam profiles and beam angles (third strategy) performed slightly better than reoptimization of profiles only, but the latter required only a few minutes of computation time, whereas full reoptimization took several hours. Conclusions: This simulation study demonstrated that replanning based on daily acquired computed tomography scans can improve liver stereotactic body radiation therapy dose delivery.

  17. Arc Statistics

    CERN Document Server

    Meneghetti, M; Dahle, H; Limousin, M

    2013-01-01

    The existence of an arc statistics problem was at the center of a strong debate in the last fifteen years. With the aim to clarify if the optical depth for giant gravitational arcs by galaxy clusters in the so called concordance model is compatible with observations, several studies were carried out which helped to significantly improve our knowledge of strong lensing clusters, unveiling their extremely complex internal structure. In particular, the abundance and the frequency of strong lensing events like gravitational arcs turned out to be a potentially very powerful tool to trace the structure formation. However, given the limited size of observational and theoretical data-sets, the power of arc statistics as a cosmological tool has been only minimally exploited so far. On the other hand, the last years were characterized by significant advancements in the field, and several cluster surveys that are ongoing or planned for the near future seem to have the potential to make arc statistics a competitive cosmo...

  18. Modeling Arcs

    CERN Document Server

    Insepov, Zeke; Veitzer, Seth; Mahalingam, Sudhakar

    2011-01-01

    Although vacuum arcs were first identified over 110 years ago, they are not yet well understood. We have since developed a model of breakdown and gradient limits that tries to explain, in a self-consistent way: arc triggering, plasma initiation, plasma evolution, surface damage and gra- dient limits. We use simple PIC codes for modeling plasmas, molecular dynamics for modeling surface breakdown, and surface damage, and mesoscale surface thermodynamics and finite element electrostatic codes for to evaluate surface properties. Since any given experiment seems to have more variables than data points, we have tried to consider a wide variety of arcing (rf structures, e beam welding, laser ablation, etc.) to help constrain the problem, and concentrate on common mechanisms. While the mechanisms can be comparatively simple, modeling can be challenging.

  19. Volumetric intensity modulated arc therapy in lung cancer: Current literature review

    Directory of Open Access Journals (Sweden)

    Suresh B Rana

    2013-01-01

    Full Text Available The volumetric intensity modulated arc therapy (VMAT is a novel radiation technique that delivers a highly conformal radiation dose to the target by allowing the simultaneous variation of gantry rotation speed, dose rate and multiple-leaf collimators leaf positions. The aim of this study was to review the current literature on two VMAT systems, RapidArc and SmartArc with main focus on planning studies of lung cancer. A systematic review of available data was conducted using MEDLINE/PubMed with the keywords ′′lung′′ and "VMAT". The published data show that VMAT techniques have clear superiority over three-dimensional conformal radiation therapy with regard to improving dose conformity and sparing of organs at risks (OARs. The data indicates that for lung tumor VMAT and intensity modulated radiation therapy (IMRT provide equivalent dose homogeneity, dose conformity and target volume coverage; however, contradictory results were obtained in terms of OARs sparing. The major advantages of VMAT over IMRT are the reduction in the number of monitor units and faster treatment delivery times without compromising the quality of the treatment plans. Moreover, faster delivery time is more patient-friendly and it minimizes intra-fractional patient motion allowing treatment volumes stay within their respective treatment margins. Current literature data shows that VMAT can be a good option to treat lung cancer; however, data on clinical trials are still lacking. The clinical trials are essential to confirm the safety and efficacy of VMAT techniques.

  20. A retrospective planning analysis comparing intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) using two optimization algorithms for the treatment of early-stage prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Elith, Craig A [British Columbia Cancer Agency, Fraser Valley Centre, Surrey, BC (Canada); School of Health Sciences, University of Newcastle, Newcastle, NSW (Australia); Dempsey, Shane E; Warren-Forward, Helen M [School of Health Sciences, University of Newcastle, Newcastle, NSW (Australia); British Columbia Cancer Agency, Fraser Valley Centre, Surrey, BC (Canada)

    2013-09-15

    The primary aim of this study is to compare intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) for the radical treatment of prostate cancer using version 10.0 (v10.0) of Varian Medical Systems, RapidArc radiation oncology system. Particular focus was placed on plan quality and the implications on departmental resources. The secondary objective was to compare the results in v10.0 to the preceding version 8.6 (v8.6). Twenty prostate cancer cases were retrospectively planned using v10.0 of Varian's Eclipse and RapidArc software. Three planning techniques were performed: a 5-field IMRT, VMAT using one arc (VMAT-1A), and VMAT with two arcs (VMAT-2A). Plan quality was assessed by examining homogeneity, conformity, the number of monitor units (MUs) utilized, and dose to the organs at risk (OAR). Resource implications were assessed by examining planning and treatment times. The results obtained using v10.0 were also compared to those previously reported by our group for v8.6. In v10.0, each technique was able to produce a dose distribution that achieved the departmental planning guidelines. The IMRT plans were produced faster than VMAT plans and displayed improved homogeneity. The VMAT plans provided better conformity to the target volume, improved dose to the OAR, and required fewer MUs. Treatments using VMAT-1A were significantly faster than both IMRT and VMAT-2A. Comparison between versions 8.6 and 10.0 revealed that in the newer version, VMAT planning was significantly faster and the quality of the VMAT dose distributions produced were of a better quality. VMAT (v10.0) using one or two arcs provides an acceptable alternative to IMRT for the treatment of prostate cancer. VMAT-1A has the greatest impact on reducing treatment time.

  1. A retrospective planning analysis comparing intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) using two optimization algorithms for the treatment of early-stage prostate cancer

    International Nuclear Information System (INIS)

    The primary aim of this study is to compare intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) for the radical treatment of prostate cancer using version 10.0 (v10.0) of Varian Medical Systems, RapidArc radiation oncology system. Particular focus was placed on plan quality and the implications on departmental resources. The secondary objective was to compare the results in v10.0 to the preceding version 8.6 (v8.6). Twenty prostate cancer cases were retrospectively planned using v10.0 of Varian's Eclipse and RapidArc software. Three planning techniques were performed: a 5-field IMRT, VMAT using one arc (VMAT-1A), and VMAT with two arcs (VMAT-2A). Plan quality was assessed by examining homogeneity, conformity, the number of monitor units (MUs) utilized, and dose to the organs at risk (OAR). Resource implications were assessed by examining planning and treatment times. The results obtained using v10.0 were also compared to those previously reported by our group for v8.6. In v10.0, each technique was able to produce a dose distribution that achieved the departmental planning guidelines. The IMRT plans were produced faster than VMAT plans and displayed improved homogeneity. The VMAT plans provided better conformity to the target volume, improved dose to the OAR, and required fewer MUs. Treatments using VMAT-1A were significantly faster than both IMRT and VMAT-2A. Comparison between versions 8.6 and 10.0 revealed that in the newer version, VMAT planning was significantly faster and the quality of the VMAT dose distributions produced were of a better quality. VMAT (v10.0) using one or two arcs provides an acceptable alternative to IMRT for the treatment of prostate cancer. VMAT-1A has the greatest impact on reducing treatment time

  2. Impact of dose rate on accuracy of intensity modulated radiation therapy plan delivery using the pretreatment portal dosimetry quality assurance and setting up the workflow at hospital levels

    OpenAIRE

    Karunakaran Kaviarasu; N Arunai Nambi Raj; Krishna Murthy, K.; A Ananda Giri Babu; Bhaskar Laxman Durga Prasad

    2015-01-01

    The aim of this study was to examine the impact of dose rate on accuracy of intensity modulated radiation therapy (IMRT) plan delivery by comparing the gamma agreement between the calculated and measured portal doses by pretreatment quality assurance (QA) using electronic portal imaging device dosimetry and creating a workflow for the pretreatment IMRT QA at hospital levels. As the improvement in gamma agreement leads to increase in the quality of IMRT treatment delivery, gamma evaluation was...

  3. Effect of acoustic field parameters on arc acoustic binding during ultrasonic wave-assisted arc welding.

    Science.gov (United States)

    Xie, Weifeng; Fan, Chenglei; Yang, Chunli; Lin, Sanbao

    2016-03-01

    As a newly developed arc welding method, power ultrasound has been successfully introduced into arc and weld pool during ultrasonic wave-assisted arc welding process. The advanced process for molten metals can be realized by utilizing additional ultrasonic field. Under the action of the acoustic wave, the plasma arc as weld heat source is regulated and its characteristics make an obvious change. Compared with the conventional arc, the ultrasonic wave-assisted arc plasma is bound significantly and becomes brighter. To reveal the dependence of the acoustic binding force on acoustic field parameters, a two-dimensional acoustic field model for ultrasonic wave-assisted arc welding device is established. The influences of the radiator height, the central pore radius, the radiator radius, and curvature radius or depth of concave radiator surface are discussed using the boundary element method. Then the authors analyze the resonant mode by this relationship curve between acoustic radiation power and radiator height. Furthermore, the best acoustic binding ability is obtained by optimizing the geometric parameters of acoustic radiator. In addition, three concave radiator surfaces including spherical cap surface, paraboloid of revolution, and rotating single curved surface are investigated systematically. Finally, both the calculation and experiment suggest that, to obtain the best acoustic binding ability, the ultrasonic wave-assisted arc welding setup should be operated under the first resonant mode using a radiator with a spherical cap surface, a small central pore, a large section radius and an appropriate curvature radius. PMID:26558995

  4. Effect of acoustic field parameters on arc acoustic binding during ultrasonic wave-assisted arc welding.

    Science.gov (United States)

    Xie, Weifeng; Fan, Chenglei; Yang, Chunli; Lin, Sanbao

    2016-03-01

    As a newly developed arc welding method, power ultrasound has been successfully introduced into arc and weld pool during ultrasonic wave-assisted arc welding process. The advanced process for molten metals can be realized by utilizing additional ultrasonic field. Under the action of the acoustic wave, the plasma arc as weld heat source is regulated and its characteristics make an obvious change. Compared with the conventional arc, the ultrasonic wave-assisted arc plasma is bound significantly and becomes brighter. To reveal the dependence of the acoustic binding force on acoustic field parameters, a two-dimensional acoustic field model for ultrasonic wave-assisted arc welding device is established. The influences of the radiator height, the central pore radius, the radiator radius, and curvature radius or depth of concave radiator surface are discussed using the boundary element method. Then the authors analyze the resonant mode by this relationship curve between acoustic radiation power and radiator height. Furthermore, the best acoustic binding ability is obtained by optimizing the geometric parameters of acoustic radiator. In addition, three concave radiator surfaces including spherical cap surface, paraboloid of revolution, and rotating single curved surface are investigated systematically. Finally, both the calculation and experiment suggest that, to obtain the best acoustic binding ability, the ultrasonic wave-assisted arc welding setup should be operated under the first resonant mode using a radiator with a spherical cap surface, a small central pore, a large section radius and an appropriate curvature radius.

  5. Radiotherapy for unresectable sinonasal cancers: Dosimetric comparison of intensity modulated radiation therapy with coplanar and non-coplanar volumetric modulated arc therapy

    International Nuclear Information System (INIS)

    Background and purpose: To compare volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) plans for treatment of unresectable paranasal sinuses cancers (PNSCs) with different clinical presentations. Material and methods: Four patients treated for primary target volume only (group 1), four requiring elective nodal irradiation (group 2) and four with positive nodes in macroscopic disease (group 3) were selected. For each patient were generated 7 fields IMRT, coplanar VMAT (c-VMAT) and non-coplanar VMAT (nc-VMAT) treatment plans. Total doses were 70 Gy and 54 Gy to high dose planning target volume (HD-PTV) and low-dose-PTV, respectively. Dose–volume histogram, conformity and homogeneity index (CI and HI), and monitor units (MUs) per Gy were evaluated. Results: VMAT provided significantly better target coverage, in terms of V100% (Volume encompassed by the isodose 100%), than IMRT, in particular when nc-VMAT was used. In general, organ at risk sparing is similar with the three approaches, although nc-VMAT can allow a statistically significant reduction of dose to contralateral parotid gland and cochlea for all three groups. Conclusions: VMAT can offer significant improvement of treatment for all unresectable PNSCs over existing IMRT techniques. In particular, nc-VMAT may be a further advantage for those patients with sinonasal cancers and involvement of the nodes in whom large volumes and complex/irregular shape have to be irradiated, even if clinical benefits should be established in the future

  6. SU-E-T-568: Improving Normal Brain Sparing with Increasing Number of Arc Beams for Volume Modulated Arc Beam Radiosurgery of Multiple Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Hossain, S; Hildebrand, K; Ahmad, S [University of Oklahoma Health Science Center, Oklahoma City, OK (United States); Larson, D; Ma, L [University of California San Francisco, San Francisco, CA (United States); Sahgal, A [University of Toronto, Toronto, Ontario (Canada)

    2014-06-01

    Purpose: Intensity modulated arc beams have been newly reported for treating multiple brain metastases. The purpose of this study was to determine the variations in the normal brain doses with increasing number of arc beams for multiple brain metastases treatments via the TrueBeam Rapidarc system (Varian Oncology, Palo Alto, CA). Methods: A patient case with 12 metastatic brain lesions previously treated on the Leksell Gamma Knife Perfexion (GK) was used for the study. All lesions and organs at risk were contoured by a senior radiation oncologist and treatment plans for a subset of 3, 6, 9 and all 12 targets were developed for the TrueBeam Rapidarc system via 3 to 7 intensity modulated arc-beams with each target covered by at least 99% of the prescribed dose of 20 Gy. The peripheral normal brain isodose volumes as well as the total beam-on time were analyzed with increasing number of arc beams for these targets. Results: All intensisty modulated arc-beam plans produced efficient treatment delivery with the beam-on time averaging 0.6–1.5 min per lesion at an output of 1200 MU/min. With increasing number of arc beams, the peripheral normal brain isodose volumes such as the 12-Gy isodose line enclosed normal brain tissue volumes were on average decreased by 6%, 11%, 18%, and 28% for the 3-, 6-, 9-, 12-target treatment plans respectively. The lowest normal brain isodose volumes were consistently found for the 7-arc treatment plans for all the cases. Conclusion: With nearly identical beam-on times, the peripheral normal brain dose was notably decreased when the total number of intensity modulated arc beams was increased when treating multiple brain metastases. Dr Sahgal and Dr Ma are currently serving on the board of international society of stereotactic radiosurgery.

  7. A Treatment Planning and Acute Toxicity Comparison of Two Pelvic Nodal Volume Delineation Techniques and Delivery Comparison of Intensity-Modulated Radiotherapy Versus Volumetric Modulated Arc Therapy for Hypofractionated High-Risk Prostate Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Myrehaug, Sten [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada); Chan, Gordon [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Craig, Tim [Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada); Weinberg, Vivian [Biostatistics Core, Helen Diller Family Comprehensive Cancer Center, University of California San Francisco, San Francisco, CA (United States); Cheng, Chun [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Roach, Mack [Department of Radiation Oncology, University of California San Francisco, San Francisco, CA (United States); Cheung, Patrick [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Sahgal, Arjun, E-mail: arjun.sahgal@sunnybrook.ca [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada)

    2012-03-15

    Purpose: To perform a comparison of two pelvic lymph node volume delineation strategies used in intensity-modulated radiotherapy (IMRT) for high risk prostate cancer and to determine the role of volumetric modulated arc therapy (VMAT). Methods and Materials: Eighteen consecutive patients accrued to an ongoing clinical trial were identified according to either the nodal contouring strategy as described based on lymphotropic nanoparticle-enhanced magnetic resonance imaging technology (9 patients) or the current Radiation Therapy Oncology Group (RTOG) consensus guidelines (9 patients). Radiation consisted of 45 Gy to prostate, seminal vesicles, and lymph nodes, with a simultaneous integrated boost to the prostate alone, to a total dose of 67.5 Gy delivered in 25 fractions. Prospective acute genitourinary and gastrointestinal toxicities were compared at baseline, during radiotherapy, and 3 months after radiotherapy. Each patient was retrospectively replanned using the opposite method of nodal contouring, and plans were normalized for dosimetric comparison. VMAT plans were also generated according to the RTOG method for comparison. Results: RTOG plans resulted in a significantly lower rate of genitourinary frequency 3 months after treatment. The dosimetric comparison showed that the RTOG plans resulted in both favorable planning target volume (PTV) coverage and lower organs at risk (OARs) and integral (ID) doses. VMAT required two to three arcs to achieve adequate treatment plans, we did not observe consistent dosimetric benefits to either the PTV or the OARs, and a higher ID was observed. However, treatment times were significantly shorter with VMAT. Conclusion: The RTOG guidelines for pelvic nodal volume delineation results in favorable dosimetry and acceptable acute toxicities for both the target and OARs. We are unable to conclude that VMAT provides a benefit compared with IMRT.

  8. Use of portal radiography to increase accuracy of dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Port films were acquired for all radiation therapy patients (n = 132) treated over a thirteen month period to 1) assist in initial treatment field set-up on Day 1, 2) for quality assurance with a second port film taken on Day 7 of radiation therapy, and 3) as a means to document the radiation treatment field as a part of the patients permanent medical record. Port films were used for both patients treated with a definitive course of radiation (n = 97 patients), and those treated palliatively (n = 35 patients). The portal radiographs were valuable in terms of the initial set-up, and to correct for any positioning or other errors at the time of the one week recheck. Changes were made, based on the initial port film on Day 1, in 53 % and 57% of treatment fields for palliative and definitive radiation patients, respectively. The changes made in both definitively and palliatively irradiated patients were usually in field position, an increase in field size to include all of the tumor, or a decrease in field size to spare normal tissue. Fewer changes were necessary based on the Day 7 recheck port films, but these day-7 rechecks are recommended for quality control. Based on the high frequency of changes introduced because of the initial port film findings, it is recommended. that port films be incorporated on a routine basis in veterinary radiation therapy

  9. Interval From Imaging to Treatment Delivery in the Radiation Surgery Age: How Long Is Too Long?

    Energy Technology Data Exchange (ETDEWEB)

    Seymour, Zachary A., E-mail: seymourz@radonc.ucsf.edu [Department of Radiation Oncology, University of California at San Francisco, San Francisco, California (United States); Fogh, Shannon E.; Westcott, Sarah K.; Braunstein, Steve [Department of Radiation Oncology, University of California at San Francisco, San Francisco, California (United States); Larson, David A. [Department of Radiation Oncology, University of California at San Francisco, San Francisco, California (United States); Department of Neurological Surgery, University of California at San Francisco, San Francisco, California (United States); Barani, Igor J.; Nakamura, Jean; Sneed, Penny K. [Department of Radiation Oncology, University of California at San Francisco, San Francisco, California (United States)

    2015-09-01

    Purpose: The purpose of this study was to evaluate workflow and patient outcomes related to frameless stereotactic radiation surgery (SRS) for brain metastases. Methods and Materials: We reviewed all treatment demographics, clinical outcomes, and workflow timing, including time from magnetic resonance imaging (MRI), computed tomography (CT) simulation, insurance authorization, and consultation to the start of SRS for brain metastases. Results: A total of 82 patients with 151 brain metastases treated with SRS were evaluated. The median times from consultation, insurance authorization, CT simulation, and MRI for treatment planning were 15, 7, 6, and 11 days to SRS. Local freedom from progression (LFFP) was lower in metastases with MRI ≥14 days before treatment (P=.0003, log rank). The 6- and 12-month LFFP rate were 95% and 75% for metastasis with interval of <14 days from MRI to treatment compared to 56% and 34% for metastases with MRI ≥14 days before treatment. On multivariate analysis, LFFP remained significantly lower for lesions with MRI ≥14 days at SRS (P=.002, Cox proportional hazards; hazard ratio: 3.4, 95% confidence interval: 1.6-7.3). Conclusions: Delay from MRI to SRS treatment delivery for brain metastases appears to reduce local control. Future studies should monitor the timing from imaging acquisition to treatment delivery. Our experience suggests that the time from MRI to treatment should be <14 days.

  10. Fabrication and in vitro characterization of gadolinium-based nanoclusters for simultaneous drug delivery and radiation enhancement

    Science.gov (United States)

    Yoo, Shannon S.; Guo, Linghong; Sun, Xuejun; Shaw, Andrew R.; Yuan, Zhipeng; Löbenberg, Raimar; Roa, Wilson H.

    2016-09-01

    We report the synthesis of a gadolinium hydroxide (Gd(OH)3) nanorod based doxorubicin (Dox) delivery system that can enhance both magnetic resonance imaging contrast and radiation sensitivity. A simple and cost effective wet-chemical method was utilized in the presence of manganese (Mn) ions and Dox to produce the Gd(OH)3:Mn·Dox nanocluster structure. The Gd(OH)3:Mn·Dox nanocluster was composed of Mn-doped Gd(OH)3 nanorods arranged in parallel with Dox as a linker molecule between the adjacent nanorods. No other studies have utilized Dox as both the linker and therapeutic molecule in a nanostructure to date. The Gd(OH)3 nanorod is reported to have no significant cellular or in vivo toxicity, which makes it an ideal base material for this biomedical application. The Gd(OH)3:Mn·Dox nanocluster exhibited paramagnetic behavior and was stable in a colloidal solution. The nanocluster also enabled high Dox loading capacity and specifically released Dox in a sustained and pH-dependent manner. The positively charged Gd(OH)3:Mn·Dox nanoclusters were readily internalized into MDA-MB-231 breast cancer cells via endocytosis, which resulted in intracellular release of Dox. The released Dox in cells was effective in conferring cytotoxicity and inhibiting proliferation of cancer cells. Furthermore, a synergistic anticancer effect could be observed with radiation treatment. Overall, the Gd(OH)3:Mn·Dox nanocluster drug delivery system described herein may have potential utility in clinics as a multifunctional theranostic nanoparticle with combined benefits in both diagnosis and therapy in the management of cancer.

  11. Fabrication and in vitro characterization of gadolinium-based nanoclusters for simultaneous drug delivery and radiation enhancement.

    Science.gov (United States)

    Yoo, Shannon S; Guo, Linghong; Sun, Xuejun; Shaw, Andrew R; Yuan, Zhipeng; Löbenberg, Raimar; Roa, Wilson H

    2016-09-23

    We report the synthesis of a gadolinium hydroxide (Gd(OH)3) nanorod based doxorubicin (Dox) delivery system that can enhance both magnetic resonance imaging contrast and radiation sensitivity. A simple and cost effective wet-chemical method was utilized in the presence of manganese (Mn) ions and Dox to produce the Gd(OH)3:Mn·Dox nanocluster structure. The Gd(OH)3:Mn·Dox nanocluster was composed of Mn-doped Gd(OH)3 nanorods arranged in parallel with Dox as a linker molecule between the adjacent nanorods. No other studies have utilized Dox as both the linker and therapeutic molecule in a nanostructure to date. The Gd(OH)3 nanorod is reported to have no significant cellular or in vivo toxicity, which makes it an ideal base material for this biomedical application. The Gd(OH)3:Mn·Dox nanocluster exhibited paramagnetic behavior and was stable in a colloidal solution. The nanocluster also enabled high Dox loading capacity and specifically released Dox in a sustained and pH-dependent manner. The positively charged Gd(OH)3:Mn·Dox nanoclusters were readily internalized into MDA-MB-231 breast cancer cells via endocytosis, which resulted in intracellular release of Dox. The released Dox in cells was effective in conferring cytotoxicity and inhibiting proliferation of cancer cells. Furthermore, a synergistic anticancer effect could be observed with radiation treatment. Overall, the Gd(OH)3:Mn·Dox nanocluster drug delivery system described herein may have potential utility in clinics as a multifunctional theranostic nanoparticle with combined benefits in both diagnosis and therapy in the management of cancer. PMID:27533280

  12. In Vivo Delivery of Tinospora cordifolia Root Extract Preventing Radiation-Induced Dystrophies in Mice Ovaries.

    Science.gov (United States)

    Sharma, Riddhi

    2015-01-01

    Unconscious and unplanned radiation exposures are a severe threat to gonads particularly ovaries. The present study aims at finding radioprotective effect of Tinospora cordifolia (Willd.) Miers root extract (TCRE) in ovaries. Swiss albino mice were divided into four groups: Group 1 served as "normal" and is administered double distilled water and Group 2 is given TCRE with optimum dosage selected as 75 mg/mice. Group 3 serving the purpose of "irradiated control" were exposed to 2.5 Gy gamma radiation. Group 4 (experimental) were administered optimum dosage of TCRE with prior exposure to 2.5 Gy gamma radiation. Follicle cell counts were scored at autopsy intervals of 24 hrs, 3 days, 7 days, 15 days, and 30 days after gamma irradiation. To understand the mechanism of radioprotection, lipid peroxidation (LPO) and glutathione (GSH) levels were also measured in all groups. TCRE supplementation rendered significant protection to ovaries by restoring follicle counts; it also reduced LPO levels and increased GSH levels in ovaries. It implies that TCRE administration protects ovaries against radiation exposure. PMID:26357520

  13. In Vivo Delivery of Tinospora cordifolia Root Extract Preventing Radiation-Induced Dystrophies in Mice Ovaries

    Directory of Open Access Journals (Sweden)

    Riddhi Sharma

    2015-01-01

    Full Text Available Unconscious and unplanned radiation exposures are a severe threat to gonads particularly ovaries. The present study aims at finding radioprotective effect of Tinospora cordifolia (Willd. Miers root extract (TCRE in ovaries. Swiss albino mice were divided into four groups: Group 1 served as “normal” and is administered double distilled water and Group 2 is given TCRE with optimum dosage selected as 75 mg/mice. Group 3 serving the purpose of “irradiated control” were exposed to 2.5 Gy gamma radiation. Group 4 (experimental were administered optimum dosage of TCRE with prior exposure to 2.5 Gy gamma radiation. Follicle cell counts were scored at autopsy intervals of 24 hrs, 3 days, 7 days, 15 days, and 30 days after gamma irradiation. To understand the mechanism of radioprotection, lipid peroxidation (LPO and glutathione (GSH levels were also measured in all groups. TCRE supplementation rendered significant protection to ovaries by restoring follicle counts; it also reduced LPO levels and increased GSH levels in ovaries. It implies that TCRE administration protects ovaries against radiation exposure.

  14. Contactless and non-invasive delivery of micro-particles lying on a non-customized rigid surface by using acoustic radiation force.

    Science.gov (United States)

    Meng, Jianxin; Mei, Deqing; Jia, Kun; Fan, Zongwei; Yang, Keji

    2014-07-01

    In the existing acoustic micro-particle delivery methods, the micro-particles always lie and slide on the surface of platform in the whole delivery process. To avoid the damage and contamination of micro-particles caused by the sliding motion, this paper deals with a novel approach to trap micro-particles from non-customized rigid surfaces and freely manipulate them. The delivery process contains three procedures: detaching, transporting, and landing. Hence, the micro-particles no longer lie on the surface, but are levitated in the fluid, during the long range transporting procedure. It is very meaningful especially for the fragile and easily contaminated targets. To quantitatively analyze the delivery process, a theoretical model to calculate the acoustic radiation force exerting upon a micro-particle near the boundary in half space is built. An experimental device is also developed to validate the delivery method. A 100 μm diameter micro-silica bead adopted as the delivery target is detached from the upper surface of an aluminum platform and levitated in the fluid. Then, it is transported along the designated path with high precision in horizontal plane. The maximum deviation is only about 3.3 μm. During the horizontal transportation, the levitation of the micro-silica bead is stable, the maximum fluctuation is less than 1 μm. The proposed method may extend the application of acoustic radiation force and provide a promising tool for microstructure or cell manipulation. PMID:24568691

  15. Fractionated stereotactic radiotherapy of benign skull-base tumors: a dosimetric comparison of volumetric modulated arc therapy with Rapidarc® versus non-coplanar dynamic arcs

    International Nuclear Information System (INIS)

    Benign tumors of the skull base are a challenge when delivering radiotherapy. An appropriate choice of radiation technique may significantly improve the patient’s outcomes. Our study aimed to compare the dosimetric results of fractionated stereotactic radiotherapy between non-coplanar dynamic arcs and coplanar volumetric modulated arctherapy (Rapidarc®). Thirteen patients treated with Novalis TX® were analysed: six vestibular schwannomas, four pituitary adenomas and three meningioma. Two treatment plans were created for each case: dynamic arcs (4–5 non coplanar arcs) and Rapidarc® (2 coplanar arcs). All tumors were >3 cm and accessible to both techniques. Patients had a stereotactic facemask (Brainlab) and were daily repositioned by Exactrac®. GTV and CTV were contoured according to tumor type. A 1-mm margin was added to the CTV to obtain PTV. Radiation doses were 52.2–54 Gy, using 1.8 Gy per fraction. Treatment time was faster with Rapidarc®. The mean PTV V95 % was 98.8 for Rapidarc® and 95.9 % for DA (p = 0.09). Homogeneity index was better with Rapidarc®: 0.06 vs. 0.09 (p = 0.01). Higher conformity index values were obtained with Rapidarc®: 75.2 vs. 67.9 % (p = 0.04). The volume of healthy brain that received a high dose (V90 %) was 0.7 % using Rapidarc® vs. 1.4 % with dynamic arcs (p = 0.05). Rapidarc® and dynamic arcs gave, respectively, a mean D40 % of 10.5 vs. 18.1 Gy (p = 0.005) for the hippocampus and a Dmean of 25.4 vs. 35.3 Gy (p = 0.008) for the ipsilateral cochlea. Low-dose delivery with Rapidarc® and dynamic arcs were, respectively, 184 vs. 166 cm3 for V20 Gy (p = 0.14) and 1265 vs. 1056 cm3 for V5 Gy (p = 0.67). Fractionated stereotactic radiotherapy using Rapidarc® for large benign tumors of the skull base provided target volume coverage that was at least equal to that of dynamics arcs, with better conformity and homogeneity and faster treatment time. Rapidarc® also offered better sparing of the ipsilateral cochlea and hippocampus

  16. Design of a Solar Greenhouse with energy Delivery by the Conversion of Near Infrared Radiation. Part 1. Optics and PV-Cells

    NARCIS (Netherlands)

    Sonneveld, P.J.; Swinkels, G.L.A.M.; Bot, G.P.A.

    2009-01-01

    In this paper the design and development of a new type of greenhouse with an integrated filter for reflecting near infrared radiation (NIR) and a solar energy delivery system is described. Especially the optical parts as the spectral selective film, the properties of the circular reflector and the e

  17. Design of a Solar Greenhouse with Energy Delivery by the Conversion of Near Infrared Radiation - Part 1 Optics and PV-cells

    NARCIS (Netherlands)

    Sonneveld, Piet; Swinkels, Gert-Jan; Bot, G.P.A.

    2009-01-01

    In this paper the design and development of a new type of greenhouse with an integrated filter for reflecting near infrared radiation (NIR) and a solar energy delivery system is described. Especially the optical parts as the spectral selective film, the properties of the circular reflector and the e

  18. Quality keeping and upgrading technique on delivery of raw fodder and so forth by using radiation

    International Nuclear Information System (INIS)

    As most of aerobic bacteria, anaerobic spore bacteria, molds and yeasts died owing to 8 to 16 kGy of γ-ray irradiation, it was found that butyric acid fermentation and aerobic putrefaction in silage did not form. As the lactobacilli bringing good fermentation quality died as well at such radiation dose, on a case of a mixed silage using the dregs, in which lactic acid was present, quality of its fermentation was good. And, many informations on changes in fatty quality and yeast activity in the silage formed by irradiation could also be obtained. As the dregs had a large difference in physical and chemical components, quality after preparation of the silage was not uniform. Materials suitable for γ-ray irradiation and radiation dose suitable for each material was found to be clarified. (G.K.)

  19. Quality keeping and upgrading technique on delivery of raw fodder and so forth by using radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Ryoei; Tanaka, Osamu; Uegaki, Ryuichi; Ando, Sada; Akiyama, Fumiaki; Yamada, Akio [National Grassland Research Inst., Nishinasuno, Tochigi (Japan)

    1998-02-01

    As most of aerobic bacteria, anaerobic spore bacteria, molds and yeasts died owing to 8 to 16 kGy of {gamma}-ray irradiation, it was found that butyric acid fermentation and aerobic putrefaction in silage did not form. As the lactobacilli bringing good fermentation quality died as well at such radiation dose, on a case of a mixed silage using the dregs, in which lactic acid was present, quality of its fermentation was good. And, many informations on changes in fatty quality and yeast activity in the silage formed by irradiation could also be obtained. As the dregs had a large difference in physical and chemical components, quality after preparation of the silage was not uniform. Materials suitable for {gamma}-ray irradiation and radiation dose suitable for each material was found to be clarified. (G.K.)

  20. TAT-Mediated Delivery of Tousled Protein to Salivary Glands Protects Against Radiation-Induced Hypofunction

    Energy Technology Data Exchange (ETDEWEB)

    Sunavala-Dossabhoy, Gulshan, E-mail: gsunav@lsuhsc.edu [Department of Biochemistry and Molecular Biology, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Palaniyandi, Senthilnathan; Richardson, Charles; De Benedetti, Arrigo [Department of Biochemistry and Molecular Biology, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Schrott, Lisa [Department of Pharmacology, Toxicology, and Neuroscience, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Caldito, Gloria [Department of Bioinformatics and Computational Biology, Louisiana State University Health Sciences Center, Shreveport, LA (United States)

    2012-09-01

    Purpose: Patients treated with radiotherapy for head-and-neck cancer invariably suffer its deleterious side effect, xerostomia. Salivary hypofunction ensuing from the irreversible destruction of glands is the most common and debilitating oral complication affecting patients undergoing regional radiotherapy. Given that the current management of xerostomia is palliative and ineffective, efforts are now directed toward preventive measures to preserve gland function. The human homolog of Tousled protein, TLK1B, facilitates chromatin remodeling at DNA repair sites and improves cell survival against ionizing radiation (IR). Therefore, we wanted to determine whether a direct transfer of TLK1B protein to rat salivary glands could protect against IR-induced salivary hypofunction. Methods: The cell-permeable TAT-TLK1B fusion protein was generated. Rat acinar cell line and rat salivary glands were pretreated with TAT peptide or TAT-TLK1B before IR. The acinar cell survival in vitro and salivary function in vivo were assessed after radiation. Results: We demonstrated that rat acinar cells transduced with TAT-TLK1B were more resistant to radiation (D{sub 0} = 4.13 {+-} 1.0 Gy; {alpha}/{beta} = 0 Gy) compared with cells transduced with the TAT peptide (D{sub 0} = 4.91 {+-} 1.0 Gy; {alpha}/{beta} = 20.2 Gy). Correspondingly, retroductal instillation of TAT-TLK1B in rat submandibular glands better preserved salivary flow after IR (89%) compared with animals pretreated with Opti-MEM or TAT peptide (31% and 39%, respectively; p < 0.01). Conclusions: The results demonstrate that a direct transfer of TLK1B protein to the salivary glands effectively attenuates radiation-mediated gland dysfunction. Prophylactic TLK1B-protein therapy could benefit patients undergoing radiotherapy for head-and-neck cancer.

  1. A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Mi Sook; Yoon, In Ha; Hong, Dong Gi; Back, Geum Mun [Dept. of Radiation Oncology, ASAN Medical Center, Seoul (Korea, Republic of)

    2015-06-15

    Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. The treatment plans for five patients, being treated on TrueBeam STx(Varian™, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Average value of CI, HI and PCI for PTV was 1.381±0.028, 1.096±0.016, 0.944±0.473 in VMAT and 1.381± 0.042, 1.136±0.042, 1.534±0.465 in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  2. Electrode Evaporation Effects on Air Arc Behavior

    Institute of Scientific and Technical Information of China (English)

    LI Xingwen; CHEN Degui; LI Rui; WU Yi; NIU Chunping

    2008-01-01

    A numerical study of the effects of copper and silver vapours on the air arc behavior is performed. The commercial software FLUENT is adapted and modified to develop a two-dimensional magneto-hydrodynamic (MHD) models of arc with the thermodynamic properties and transport coefficients, net emission coefficient for the radiation model of 99% ai-1% Cu, 99% air-1% Ag, and pure air, respectively. The simulation result demonstrates that vaporization of the electrode material may cool the arc center region and reduce the arc velocity. The effects of Ag vapour are stronger compared to those of Cu vapour.

  3. In Vivo Delivery of Tinospora cordifolia Root Extract Preventing Radiation-Induced Dystrophies in Mice Ovaries

    OpenAIRE

    Riddhi Sharma

    2015-01-01

    Unconscious and unplanned radiation exposures are a severe threat to gonads particularly ovaries. The present study aims at finding radioprotective effect of Tinospora cordifolia (Willd.) Miers root extract (TCRE) in ovaries. Swiss albino mice were divided into four groups: Group 1 served as “normal” and is administered double distilled water and Group 2 is given TCRE with optimum dosage selected as 75 mg/mice. Group 3 serving the purpose of “irradiated control” were exposed to 2.5 Gy gamma r...

  4. Radiation-grafting of acrylamide onto silicone rubber films for diclofenac delivery

    Science.gov (United States)

    Magaña, Hector; Palomino, Kenia; Cornejo-Bravo, Jose M.; Alvarez-Lorenzo, Carmen; Concheiro, Angel; Bucio, Emilio

    2015-02-01

    This work focuses on the pre-irradiation grafting of acrylamide (AAm) onto silicone rubber films (SR) and evaluates the effect of gamma-ray radiation conditions on the grafting yield, which in turn may influence the performance of the grafted materials as components of drug-eluting devices. Pristine and modified SR were characterized using FTIR-ATR, DSC, TGA, swelling, and water contact angle analysis in order to elucidate the effects of AAm grafting onto SR. Grafted films with content in AAm ranging from 0.81% to 22.20% showed excellent cytocompatibility against fibroblasts, and capability to uptake the anti-inflammatory drug diclofenac. Amount of drug loaded directly correlated with the grafting degree of the films. Drug release studies were performed at pH 7.4 and 37 °C (physiological conditions). Most grafted films released the drug in a sustained way for at least three hours.

  5. Arc saw development report

    International Nuclear Information System (INIS)

    The arc saw is one of the key components of the Contaminated Equipment Volume Reduction (CEVR) Program. This report describes the progress of the arc saw from its inception to its current developmental status. History of the arc saw and early contributors are discussed. Particular features of the arc saw and their advantages for CEVR are detailed. Development of the arc saw including theory of operation, pertinent experimental results, plans for the large arc saw and advanced control systems are covered. Associated topics such as potential applications for the arc saw and other arc saw installations in the world is also touched upon

  6. Rapid Arc, helical tomotherapy, sliding window intensity modulated radiotherapy and three dimensional conformal radiation for localized prostate cancer: A dosimetric comparison

    Directory of Open Access Journals (Sweden)

    Rajesh A Kinhikar

    2014-01-01

    Full Text Available Objective: The objective of this study was to investigate the potential role of RapidArc (RA compared with helical tomotherapy (HT, sliding window intensity modulated radiotherapy (SW IMRT and three-dimensional conformal radiation therapy (3D CRT for localized prostate cancer. Materials and Methods: Prescription doses ranged from 60 Gy to planning target volume (PTV and 66.25 Gy for clinical target volume prostate (CTV-P over 25-30 fractions. PTV and CTV-P coverage were evaluated by conformity index (CI and homogeneity index (HI. Organ sparing comparison was done with mean doses to rectum and bladder. Results: CI 95 were 1.0 ± 0.01 (RA, 0.99 ± 0.01 (HT, 0.97 ± 0.02 (IMRT, 0.98 ± 0.02 (3D CRT for PTV and 1.0 ± 0.00 (RA, HT, SW IMRT and 3D CRT for CTV-P. HI was 0.11 ± 0.03 (RA, 0.16 ± 0.08 (HT, 0.12 ± 0.03 (IMRT, 0.06 ± 0.01 (3D CRT for PTV and 0.03 ± 0.00 (RA, 0.05 ± 0.01 (HT, 0.03 ± 0.01 (SW IMRT and 3D CRT for CTV-P. Mean dose to bladder were 23.68 ± 13.23 Gy (RA, 24.55 ± 12.51 Gy (HT, 19.82 ± 11.61 Gy (IMRT and 23.56 ± 12.81 Gy (3D CRT, whereas mean dose to rectum was 36.85 ± 12.92 Gy (RA, 33.18 ± 11.12 Gy (HT, IMRT and 38.67 ± 12.84 Gy (3D CRT. Conclusion: All studied intensity-modulated techniques yield treatment plans of significantly improved quality when compared with 3D CRT, with HT providing best organs at risk sparing and RA being the most efficient treatment option, reducing treatment time to 1.45-3.7 min and monitor unit to <400 for a 2 Gy fraction.

  7. Air and silica core Bragg fibers for radiation delivery in the wavelength range 0.6-1.5 μ m

    Science.gov (United States)

    Frank, Milan; Jelínek, Michal; Kubeček, Václav; Kašík, Ivan; Podrazký, Ondřej; Matějec, Vlastimil

    2016-09-01

    This paper presents fundamental characteristics of laboratory designed and fabricated Bragg fibers with air and silica cores at wavelengths of 632, 975, 1064 and 1550 nm. Fibers with the 26- μ m-silica core and 5- or 73- μ m-air cores in diameters and claddings of 3 pairs of Bragg layers were prepared from one preform. The overall transmittance, attenuation coefficients, coupling losses, bending losses, and damage-intensity thresholds were determined using four continuous-wave laser sources with the maximum output power of 300 mW and a pulsed 9 ns laser with the maximum output energy up to 1 mJ. The lowest attenuation coefficient of about 70 dB/km was determined at 1064 nm with the 73- μ m-air-core Bragg fiber. All fibers have been found to exhibit negligible bending losses down to the bending diameters of 5 cm. In comparison with the conventional gradient optical fiber, all the prepared Bragg fibers have approximately six times higher damage intensity threshold of about 30 GWcm-2 and therefore they are very suitable for high power laser radiation delivery.

  8. Simulation of the Effects of Several Factors on Arc Plasma Behavior in Low Voltage Circuit Breaker

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Taking into account the properties of the arc plasma and the electromagnetic, heat and radiative phenomena, commercial computational fluid dynamics software PHOENICS has been adapted and modified to develop the three-dimensional magneto-hydrodynamic (MHD)model of arc in a low voltage circuit breaker. The effects of the arc ignition location, venting size and gassing material on arc behavior have been investigated. The analysis of the results show that the arc velocity accelerates with the increase in the distance between arc ignition location and of the venting size, and the existence of the gassing material is beneficial to improving the arc voltage and reducing the arc temperature.

  9. Aerosol delivery of beclin1 enhanced the anti-tumor effect of radiation in the lungs of K-rasLA1 mice

    International Nuclear Information System (INIS)

    Radiotherapy alone has several limitations for treating lung cancer. Inhalation, a non-invasive approach for direct delivery of therapeutic agents to the lung, may help to enhance the therapeutic efficacy of radiation. Up-regulating beclin1, known as a tumor suppressor gene that plays a major role in autophagy, may sensitize tumors and lead to tumor regression in lungs of K-rasLA1 lung cancer model mice. To minimize the side-effects of radiotherapy, fractionated exposures (five times, 24-h interval) with low dose (2 Gy) of radiation to the restricted area (thorax, 2 cm) were conducted. After sensitizing the lungs with radiation, beclin1, complexed with a nano-sized biodegradable poly (ester amine), was prepared and delivered into the murine lung via aerosol three times/week for four weeks. In a histopathological analysis, animals treated with beclin1 and radiation showed highly significant tumor regression and low progression to adenocarcinoma. An increase in the number of autophagic vacuoles and secondary lysosomes was detected. Dissociation of beclin1-bcl2 stimulated autophagy activation and showed a synergistic anti-tumor effect by inhibiting the Akt-mTOR pathway, cell proliferation and angiogenesis. The combination of radiation with non-invasive aerosol delivery of beclin1 may provide a prospect for developing novel therapy regimens applicable in clinics. (author)

  10. Dosimetry study on conformal radiation therapy, intensity modulated radiation therapy and intensity modulated arc radiotherapy in middle thoracic esophageal cancer%胸中段食管癌三维适形放疗、调强放疗及旋转调强放疗的剂量学研究

    Institute of Scientific and Technical Information of China (English)

    孙尧; 刘希军; 刘同海; 于甬华; 尹勇

    2013-01-01

    Objective To compare the dosimetry of three different radiation therapy plans [threedimensional conformal radiation therapy (3DCRT),intensity modulated radiation therapy (IMRT),intensity modulated arc radiotherapy (IMAT)].Methods Selected 15 cases with middle thoracic esophageal cancer,Varian Eclipse 8.6 planning systems were designed with 3DCRT,IMRT,IMAT,3DCRT using 5-8 coplanar radiation fields,IMRT using 7 coplanar radiation fields,IMAT using 2 radians.Three planned dose difference were compared.Results Compared with 3DCRT,IMRT and IMAT were better with heterogeneity index (HI),conformality index (CI),VPTV 95 %,V5,V20,V35 of total lung,and V30 of heart (t =2.531,P< 0.05).There was no statistically significant difference for the V10,V15,V25,V30 mean dose of total lung,the mean dose of heart,the maximum dose of spinal cord,and the minimum dose of PTV among the three plans (t =1.325,P >0.05).Conclusion IMAT and IMRT are similar in the middle thoracic esophageal cancer radiotherapy target volume dose coverage and organs at risk protection,they are better than 3DCRT.IMAT in the monitor units and delivery time are less than IMRT.%目的 研究胸中段食管癌三维适形放疗(3DCRT)、调强放疗(IMRT)、旋转调强放疗(IMAT)3种放疗计划的剂量差异.方法 选取胸中段食管癌患者15例,以Varian Eclipse 8.6计划系统分别设计3DCRT、IMRT、IMAT 3种放疗计划,其中3DCRT采用5~8个共面射野,IMRT采用7个共面射野,IMAT采用2个弧度.比较3种计划的剂量学差异.结果 IMRT、IMRT的靶区均匀指数(HI)、适形指数(CI)、95%计划靶体积(PTV)体积剂量均优于3DCRT,全肺V5、V20、V35、心脏V30受照剂量低于3DCRT(t=2.531,P< 0.05),而在全肺V10、V15、V25、V30、全肺平均、心脏平均、脊髓Dmax剂量之间三者的差异均无统计学意义(t=1.325,P>0.05).结论 IMAT与IMRT在胸中段食管癌放疗靶区体积剂量覆盖和危及器官保护方面相似,二者均优于3DCRT.IMAT

  11. Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Colvill, Emma [Radiation Physics Laboratory, University of Sydney, Sydney, NSW (Australia); Northern Sydney Cancer Centre, Royal North Shore Hospital, St. Leonards, NSW (Australia); Booth, Jeremy T. [Northern Sydney Cancer Centre, Royal North Shore Hospital, St. Leonards, NSW (Australia); School of Physics, University of Sydney, Sydney, NSW (Australia); O' Brien, Ricky T. [Radiation Physics Laboratory, University of Sydney, Sydney, NSW (Australia); Eade, Thomas N.; Kneebone, Andrew B. [Northern Sydney Cancer Centre, Royal North Shore Hospital, St. Leonards, NSW (Australia); Poulsen, Per R. [Aarhus University Hospital, Aarhus (Denmark); Keall, Paul J., E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, University of Sydney, Sydney, NSW (Australia)

    2015-08-01

    Purpose: To test the hypothesis that multileaf collimator (MLC) tracking improves the consistency between the planned and delivered dose compared with the dose without MLC tracking, in the setting of a prostate cancer volumetric modulated arc therapy trial. Methods and Materials: Multileaf collimator tracking was implemented for 15 patients in a prostate cancer radiation therapy trial; in total, 513 treatment fractions were delivered. During each treatment fraction, the prostate trajectory and treatment MLC positions were collected. These data were used as input for dose reconstruction (multiple isocenter shift method) to calculate the treated dose (with MLC tracking) and the dose that would have been delivered had MLC tracking not been applied (without MLC tracking). The percentage difference from planned for target and normal tissue dose-volume points were calculated. The hypothesis was tested for each dose-volume value via analysis of variance using the F test. Results: Of the 513 fractions delivered, 475 (93%) were suitable for analysis. The mean difference and standard deviation between the planned and treated MLC tracking doses and the planned and without-MLC tracking doses for all 475 fractions were, respectively, PTV D{sub 99%} −0.8% ± 1.1% versus −2.1% ± 2.7%; CTV D{sub 99%} −0.6% ± 0.8% versus −0.6% ± 1.1%; rectum V{sub 65%} 1.6% ± 7.9% versus −1.2% ± 18%; and bladder V{sub 65%} 0.5% ± 4.4% versus −0.0% ± 9.2% (P<.001 for all dose-volume results). Conclusion: This study shows that MLC tracking improves the consistency between the planned and delivered doses compared with the modeled doses without MLC tracking. The implications of this finding are potentially improved patient outcomes, as well as more reliable dose-volume data for radiobiological parameter determination.

  12. Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: retrospective physician surveys including chart reviews at numerous centers.

    Science.gov (United States)

    Gossman, Michael S; Wilkinson, Jeffrey D; Mallick, Avishek

    2014-01-01

    In a 2-part study, we first examined the results of 71 surveyed physicians who provided responses on how they address the management of patients who maintained either a pacemaker or a defibrillator during radiation treatment. Second, a case review study is presented involving 112 medical records reviewed at 18 institutions to determine whether there was a change in the radiation prescription for the treatment of the target cancer, the method of radiation delivery, or the method of radiation image acquisition. Statistics are provided to illustrate the level of administrative policy; the level of communication between radiation oncologists and heart specialists; American Joint Committee on Cancer (AJCC) staging and classification; National Comprehensive Cancer Network (NCCN) guidelines; tumor site; patient׳s sex; patient׳s age; device type; manufacturer; live monitoring; and the reported decisions for planning, delivery, and imaging. This survey revealed that 37% of patient treatments were considered for some sort of change in this regard, whereas 59% of patients were treated without regard to these alternatives when available. Only 3% of all patients were identified with an observable change in the functionality of the device or patient status in comparison with 96% of patients with normal behavior and operating devices. Documented changes in the patient׳s medical record included 1 device exhibiting failure at 0.3-Gy dose, 1 device exhibiting increased sensor rate during dose delivery, 1 patient having an irregular heartbeat leading to device reprogramming, and 1 patient complained of twinging in the chest wall that resulted in a respiratory arrest. Although policies and procedures should directly involve the qualified medical physicist for technical supervision, their sufficient involvement was typically not requested by most respondents. No treatment options were denied to any patient based on AJCC staging, classification, or NCCN practice standards.

  13. Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: Retrospective physician surveys including chart reviews at numerous centers

    Energy Technology Data Exchange (ETDEWEB)

    Gossman, Michael S., E-mail: MGossman@TSRCC.com [Regulation Directive Medical Physics, Russell, KY (United States); Wilkinson, Jeffrey D. [Medtronic, Inc., Mounds View, MN (United States); Mallick, Avishek [Department of Mathematics, Marshall University, Huntington, WV (United States)

    2014-01-01

    In a 2-part study, we first examined the results of 71 surveyed physicians who provided responses on how they address the management of patients who maintained either a pacemaker or a defibrillator during radiation treatment. Second, a case review study is presented involving 112 medical records reviewed at 18 institutions to determine whether there was a change in the radiation prescription for the treatment of the target cancer, the method of radiation delivery, or the method of radiation image acquisition. Statistics are provided to illustrate the level of administrative policy; the level of communication between radiation oncologists and heart specialists; American Joint Committee on Cancer (AJCC) staging and classification; National Comprehensive Cancer Network (NCCN) guidelines; tumor site; patient's sex; patient's age; device type; manufacturer; live monitoring; and the reported decisions for planning, delivery, and imaging. This survey revealed that 37% of patient treatments were considered for some sort of change in this regard, whereas 59% of patients were treated without regard to these alternatives when available. Only 3% of all patients were identified with an observable change in the functionality of the device or patient status in comparison with 96% of patients with normal behavior and operating devices. Documented changes in the patient's medical record included 1 device exhibiting failure at 0.3-Gy dose, 1 device exhibiting increased sensor rate during dose delivery, 1 patient having an irregular heartbeat leading to device reprogramming, and 1 patient complained of twinging in the chest wall that resulted in a respiratory arrest. Although policies and procedures should directly involve the qualified medical physicist for technical supervision, their sufficient involvement was typically not requested by most respondents. No treatment options were denied to any patient based on AJCC staging, classification, or NCCN practice standards.

  14. Gas arc constriction for plasma arc welding

    Science.gov (United States)

    McGee, William F. (Inventor); Rybicki, Daniel J. (Inventor)

    1994-01-01

    A welding torch for plasma arc welding apparatus has an inert gas applied circumferentially about the arc column externally of the constricting nozzle so as to apply a constricting force on the arc after it has exited the nozzle orifice and downstream of the auxiliary shielding gas. The constricting inert gas is supplied to a plenum chamber about the body of the torch and exits through a series of circumferentially disposed orifices in an annular wall forming a closure at the forward end of the constricting gas plenum chamber. The constricting force of the circumferential gas flow about the arc concentrates and focuses the arc column into a more narrow and dense column of energy after exiting the nozzle orifice so that the arc better retains its energy density prior to contacting the workpiece.

  15. Rotating arc spark plug

    Science.gov (United States)

    Whealton, John H.; Tsai, Chin-Chi

    2003-05-27

    A spark plug device includes a structure for modification of an arc, the modification including arc rotation. The spark plug can be used in a combustion engine to reduce emissions and/or improve fuel economy. A method for operating a spark plug and a combustion engine having the spark plug device includes the step of modifying an arc, the modifying including rotating the arc.

  16. Numerical investigations of arc behaviour in gas metal arc welding using ANSYS CFX

    Science.gov (United States)

    Schnick, M.; Fuessel, U.; Hertel, M.; Spille-Kohoff, A.; Murphy, A. B.

    2011-06-01

    Current numerical models of gas metal arc welding (GMAW) are trying to combine magnetohydrodynamics (MHD) models of the arc and volume of fluid (VoF) models of metal transfer. They neglect vaporization and assume an argon atmosphere for the arc region, as it is common practice for models of gas tungsten arc welding. These models predict temperatures above 20 000 K and a temperature distribution similar to tungsten inert gas (TIG) arcs. However, current spectroscopic temperature measurements in GMAW arcs demonstrate much lower arc temperatures. In contrast to TIG arcs they found a central local minimum of the radial temperature distribution. The paper presents a GMAW arc model that considers metal vapour and which is in a very good agreement with experimentally observed temperatures. Furthermore, the model is able to predict the local central minimum in the radial temperature and the radial electric current density distributions for the first time. The axially symmetric model of the welding torch, the work piece, the wire and the arc (fluid domain) implements MHD as well as turbulent mixing and thermal demixing of metal vapour in argon. The mass fraction of iron vapour obtained from the simulation shows an accumulation in the arc core and another accumulation on the fringes of the arc at 2000 to 5000 K. The demixing effects lead to very low concentrations of iron between these two regions. Sensitive analyses demonstrate the influence of the transport and radiation properties of metal vapour, and the evaporation rate relative to the wire feed. Finally the model predictions are compared with the measuring results of Zielińska et al.

  17. Industry-relevant magnetron sputtering and cathodic arc ultra-high vacuum deposition system for in situ x-ray diffraction studies of thin film growth using high energy synchrotron radiation.

    Science.gov (United States)

    Schroeder, J L; Thomson, W; Howard, B; Schell, N; Näslund, L-Å; Rogström, L; Johansson-Jõesaar, M P; Ghafoor, N; Odén, M; Nothnagel, E; Shepard, A; Greer, J; Birch, J

    2015-09-01

    We present an industry-relevant, large-scale, ultra-high vacuum (UHV) magnetron sputtering and cathodic arc deposition system purposefully designed for time-resolved in situ thin film deposition/annealing studies using high-energy (>50 keV), high photon flux (>10(12) ph/s) synchrotron radiation. The high photon flux, combined with a fast-acquisition-time (<1 s) two-dimensional (2D) detector, permits time-resolved in situ structural analysis of thin film formation processes. The high-energy synchrotron-radiation based x-rays result in small scattering angles (<11°), allowing large areas of reciprocal space to be imaged with a 2D detector. The system has been designed for use on the 1-tonne, ultra-high load, high-resolution hexapod at the P07 High Energy Materials Science beamline at PETRA III at the Deutsches Elektronen-Synchrotron in Hamburg, Germany. The deposition system includes standard features of a typical UHV deposition system plus a range of special features suited for synchrotron radiation studies and industry-relevant processes. We openly encourage the materials research community to contact us for collaborative opportunities using this unique and versatile scientific instrument.

  18. Investigation of dose homogeneity for loose helical tomotherapy delivery in the context of breath-hold radiation therapy

    Science.gov (United States)

    Kim, Bryan; Kron, Tomas; Battista, Jerry; Van Dyk, Jake

    2005-05-01

    Loose helical delivery is a potential solution to account for respiration-driven tumour motion in helical tomotherapy (HT). In this approach, a treatment is divided into a set of interlaced 'loose' helices commencing at different gantry angles. Each loose helix covers the entire target length in one gantry rotation during a single breath-hold. The dosimetric characteristics of loose helical delivery were investigated by delivering a 6 MV photon beam in a HT-like manner. Multiple scenarios of conventional 'tight' HT and loose helical deliveries were modelled in treatment planning software, and carried out experimentally with Kodak EDR2 film. The advantage of loose helical delivery lies in its ability to produce a more homogeneous dose distribution by eliminating the 'thread' effect—an inherent characteristic of HT, which results in dose modulations away from the axis of gantry rotation. However, loose helical delivery was also subjected to undesirable dose modulations in the direction of couch motion (termed 'beating' effect), when the ratio between the number of beam projections per gantry rotation (n) and pitch factor (p) was a non-integer. The magnitude of dose modulations decreased with an increasing n/p ratio. The results suggest that for the current HT unit (n = 51), dose modulations could be kept under 5% by selecting a pitch factor smaller than 7. A pitch factor of this magnitude should be able to treat a target up to 30 cm in length. Loose helical delivery should increase the total session time only by a factor of 2, while the planning time should stay the same since the total number of beam projections remains unchanged. Considering its dosimetric advantage and clinical practicality, loose helical delivery is a promising solution for the future HT treatments of respiration-driven targets.

  19. Policy, development and delivery of education and training programmes in radiation protection: a crucial contribution to the safe use of ionising radiation

    International Nuclear Information System (INIS)

    Need for radiation protection knowledge, skills and competences: Today’s situation - Over past years: decrease in number of high-level competences in radiation protection. However, increased attention to RP is needed: more technologies (and more frequently used) rely on ionizing radiation. Actions: Fill the gap - Increase awareness that knowledge of RP science and adequate skills are important (at all levels in medical, industry, research, …). Prepare for future needs - Support of young students and professionals in their need to gain and maintain high level radiation protection competences. Attract new people: Provide adequate E and T - Develop good infrastructure for education and training: → to combat the decline in expertise; → to assure high level of future RP knowledge and skills; → Overall safe use of ionizing radiation

  20. Peek Arc Consistency

    CERN Document Server

    Bodirsky, Manuel

    2008-01-01

    This paper studies peek arc consistency, a reasoning technique that extends the well-known arc consistency technique for constraint satisfaction. In contrast to other more costly extensions of arc consistency that have been studied in the literature, peek arc consistency requires only linear space and quadratic time and can be parallelized in a straightforward way such that it runs in linear time with a linear number of processors. We demonstrate that for various constraint languages, peek arc consistency gives a polynomial-time decision procedure for the constraint satisfaction problem. We also present an algebraic characterization of those constraint languages that can be solved by peek arc consistency, and study the robustness of the algorithm.

  1. Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA)

    International Nuclear Information System (INIS)

    Purpose: To propose single-isocenter dynamic conformal arcs (SIDCA), a novel technique for radiosurgery of multiple brain metastases, and to compare SIDCA with volumetric modulated arc therapy (VMAT) and multiple-isocenter dynamic conformal arcs (MIDCA) for plan quality. Methods and materials: SIDCA, MIDCA, and VMAT plans were created on 6 patients with 3–5 metastases. Plans were evaluated using Radiation Therapy Oncology Group conformity index (RCI), Paddick conformity index (PCI), gradient index (GI), volumes that received more than 100% (V100%), 50% (V50%), 25% (V25%) and 10% (V10%) of prescription dose, total monitor units (MUs), and delivery time (DT). Results: SIDCA achieved conformal plans (RCI = 1.38 ± 0.12, PCI = 0.72 ± 0.06) with steep dose fall-off (GI = 3.97 ± 0.51). MIDCA plans had comparable plan quality and MUs as SIDCA, but 52% longer DT. The VMAT plans had better conformity (RCI = 1.15 ± 0.09, p < 0.01 and PCI = 0.86 ± 0.06, p < 0.01) than SIDCA, worse GI (4.34 ± 0.46, p < 0.01), higher V25% (p = 0.05) and V10% (p = 0.02), 49% less MUs and 46% shorter DT. Conclusions: All three techniques achieved conformal plans with steep dose fall-off from targets. SIDCA plans had similar plan quality as MIDCA but more efficient to delivery. SIDCA plans had lower peripheral dose spread than VMAT; VMAT plans had better conformity and faster delivery time than SIDCA

  2. Wire + Arc Additive Manufacturing

    OpenAIRE

    Williams, Stewart W.; Martina, Filomeno; Addison, Adrian C.; Ding, Jialuo; Pardal, Goncalo; Colegrove, Paul A.

    2016-01-01

    Depositing large components (>10 kg) in titanium, aluminium, steel and other metals is possible using Wire + Arc Additive Manufacturing. This technology adopts arc welding tools and wire as feedstock for additive manufacturing purposes. High deposition rates, low material and equipment costs, and good structural integrity make Wire+Arc Additive Manufacturing a suitable candidate for replacing the current method of manufacturing from solid billets or large forgings, especially with regards to ...

  3. Welding arc plasma physics

    Science.gov (United States)

    Cain, Bruce L.

    1990-01-01

    The problems of weld quality control and weld process dependability continue to be relevant issues in modern metal welding technology. These become especially important for NASA missions which may require the assembly or repair of larger orbiting platforms using automatic welding techniques. To extend present welding technologies for such applications, NASA/MSFC's Materials and Processes Lab is developing physical models of the arc welding process with the goal of providing both a basis for improved design of weld control systems, and a better understanding of how arc welding variables influence final weld properties. The physics of the plasma arc discharge is reasonably well established in terms of transport processes occurring in the arc column itself, although recourse to sophisticated numerical treatments is normally required to obtain quantitative results. Unfortunately the rigor of these numerical computations often obscures the physics of the underlying model due to its inherent complexity. In contrast, this work has focused on a relatively simple physical model of the arc discharge to describe the gross features observed in welding arcs. Emphasis was placed of deriving analytic expressions for the voltage along the arc axis as a function of known or measurable arc parameters. The model retains the essential physics for a straight polarity, diffusion dominated free burning arc in argon, with major simplifications of collisionless sheaths and simple energy balances at the electrodes.

  4. Evaluation the implementation of volumetric modulated arc therapy QA in the radiation therapy treatment according to various factors by using the portal dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hyeon; Bae, Sun Myung; Seo, Dong Rin; Kang, Tae Young; Baek, Geum Mun [Dept. of Radiation Oncology, ASAN Medical Center, Seoul (Korea, Republic of)

    2015-12-15

    The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Test was used for TrueBeam STx{sup TM} (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  5. Use of FDG-PET to guide dose prescription heterogeneity in stereotactic body radiation therapy for lung cancers with volumetric modulated arc therapy: a feasibility study

    International Nuclear Information System (INIS)

    The aim of this study was to assess if FDG-PET could guide dose prescription heterogeneity and decrease arbitrary location of hotspots in SBRT. For three patients with stage I lung cancer, a CT-simulation and a FDG-PET were registered to define respectively the PTVCT and the biological target volume (BTV). Two plans involving volumetric modulated arc therapy (VMAT) and simultaneous integrated boost (SIB) were calculated. The first plan delivered 4 × 12 Gy within the PTVCT and the second plan, with SIB, 4 × 12 Gy and 13.8 Gy (115% of the prescribed dose) within the PTVCT and the BTV respectively. The Dmax-PTVCT had to be inferior to 60 Gy (125% of the prescribed dose). Plans were evaluated through the D95%, D99% and Dmax-PTVCT, the D2 cm, the R50% and R100% and the dice similarity coefficient (DSC) between the isodose 115% and BTV. DSC allows verifying the location of the 115% isodose (ideal value = 1). The mean PTVCT and BTV were 36.7 (±12.5) and 6.5 (±2.2) cm3 respectively. Both plans led to similar target coverage, same doses to the OARs and equivalent fall-off of the dose outside the PTVCT. On the other hand, the location of hotspots, evaluated through the DSC, was improved for the SIB plans with a mean DSC of 0.31 and 0.45 for the first and the second plans respectively. Use of PET to decrease arbitrary location of hotspots is feasible with VMAT and SIB for lung cancer

  6. Calculation of radiative corrections to virtual compton scattering - absolute measurement of the energy of Jefferson Lab. electron beam (hall A) by a magnetic method: arc project

    International Nuclear Information System (INIS)

    This thesis presents the radiative corrections to the virtual compton scattering and the magnetic method adopted in the Hall A at Jefferson Laboratory, to measure the electrons beam energy with an accuracy of 104. The virtual compton scattering experiments allow the access to the generalised polarizabilities of the protons. The extraction of these polarizabilities is obtained by the experimental and theoretical cross sections comparison. That's why the systematic errors and the radiative effects of the experiments have to be controlled very seriously. In this scope, a whole calculation of the internal radiative corrections has been realised in the framework of the quantum electrodynamic. The method of the dimensional regularisation has been used to the treatment of the ultraviolet and infra-red divergences. The absolute measure method of the energy, takes into account the magnetic deviation, made up of eight identical dipoles. The energy is determined from the deviation angle calculation of the beam and the measure of the magnetic field integral along the deviation

  7. Phase I-II study of hypofractionated simultaneous integrated boost using volumetric modulated arc therapy for adjuvant radiation therapy in breast cancer patients: a report of feasibility and early toxicity results in the first 50 treatments

    International Nuclear Information System (INIS)

    To report results in terms of feasibility and early toxicity of hypofractionated simultaneous integrated boost (SIB) approach with Volumetric Modulated Arc Therapy (VMAT) as adjuvant treatment after breast-conserving surgery. Between September 2010 and May 2011, 50 consecutive patients presenting early-stage breast cancer were submitted to adjuvant radiotherapy with SIB-VMAT approach using RapidArc in our Institution (Istituto Clinico Humanitas ICH). Three out of 50 patients were irradiated bilaterally (53 tumours in 50 patients). All patients were enrolled in a phase I-II trial approved by the ICH ethical committee. All 50 patients enrolled in the study underwent VMAT-SIB technique to irradiate the whole breast with concomitant boost irradiation of the tumor bed. Doses to whole breast and surgical bed were 40.5 Gy and 48 Gy respectively, delivered in 15 fractions over 3 weeks. Skin toxicities were recorded during and after treatment according to RTOG acute radiation morbidity scoring criteria with a median follow-up of 12 months (range 8–16). Cosmetic outcomes were assessed as excellent/good or fair/poor. The median age of the population was 68 years (range 36–88). According to AJCC staging system, 38 breast lesions were classified as pT1, and 15 as pT2; 49 cases were assessed as N0 and 4 as N1. The maximum acute skin toxicity by the end of treatment was Grade 0 in 20/50 patients, Grade 1 in 32/50, Grade 2 in 0 and Grade 3 in 1/50 (one of the 3 cases of bilateral breast irradiation). No Grade 4 toxicities were observed. All Grade 1 toxicities had resolved within 3 weeks. No significant differences in cosmetic scores on baseline assessment vs. 3 months and 6 months after the treatment were observed: all patients were scored as excellent/good (50/50) compared with baseline; no fair/poor judgment was recorded. No other toxicities or local failures were recorded during follow-up. The 3-week course of postoperative radiation using VMAT with SIB showed to be

  8. Feasibility of single-isocenter, multi-arc non-coplanar volumetric modulated arc therapy for multiple brain tumors using a linear accelerator with a 160-leaf multileaf collimator: a phantom study

    OpenAIRE

    Iwai, Yoshio; Ozawa, Shuichi; Ageishi, Tatsuya; Pellegrini, Roberto; Yoda, Kiyoshi

    2014-01-01

    The feasibility of single isocenter, multi-arc non-coplanar volumetric modulated arc therapy (VMAT) for multiple brain tumors was studied using an Elekta Synergy linear accelerator with an Agility multileaf collimator and a Monaco treatment planning system. Two VMAT radiosurgery plans consisting of a full arc and three half arcs were created with a prescribed dose of 20 Gy in a single fraction. After dose delivery to a phantom, ionization chambers and radiochromic films were used for dose mea...

  9. Daily Orthogonal Kilovoltage Imaging Using a Gantry-Mounted On-Board Imaging System Results in a Reduction in Radiation Therapy Delivery Errors

    International Nuclear Information System (INIS)

    Purpose: To determine whether the use of routine image guided radiation therapy (IGRT) using pretreatment on-board imaging (OBI) with orthogonal kilovoltage X-rays reduces treatment delivery errors. Methods and Materials: A retrospective review of documented treatment delivery errors from 2003 to 2009 was performed. Following implementation of IGRT in 2007, patients received daily OBI with orthogonal kV X-rays prior to treatment. The frequency of errors in the pre- and post-IGRT time frames was compared. Treatment errors (TEs) were classified as IGRT-preventable or non-IGRT-preventable. Results: A total of 71,260 treatment fractions were delivered to 2764 patients. A total of 135 (0.19%) TEs occurred in 39 (1.4%) patients (3.2% in 2003, 1.1% in 2004, 2.5% in 2005, 2% in 2006, 0.86% in 2007, 0.24% in 2008, and 0.22% in 2009). In 2007, the TE rate decreased by >50% and has remained low (P = .00007, compared to before 2007). Errors were classified as being potentially preventable with IGRT (e.g., incorrect site, patient, or isocenter) vs. not. No patients had any IGRT-preventable TEs from 2007 to 2009, whereas there were 9 from 2003 to 2006 (1 in 2003, 2 in 2004, 2 in 2005, and 4 in 2006; P = .0058) before the implementation of IGRT. Conclusions: IGRT implementation has a patient safety benefit with a significant reduction in treatment delivery errors. As such, we recommend the use of IGRT in routine practice to complement existing quality assurance measures.

  10. The time-dependent prize-collecting arc routing problem

    DEFF Research Database (Denmark)

    Black, Dan; Eglese, Richard; Wøhlk, Sanne

    2013-01-01

    A new problem is introduced named the Time-Dependent Prize-Collecting Arc Routing Problem (TD-PARP). It is particularly relevant to situations where a transport manager has to choose between a number of full truck load pick-ups and deliveries on a road network where travel times change with the t......A new problem is introduced named the Time-Dependent Prize-Collecting Arc Routing Problem (TD-PARP). It is particularly relevant to situations where a transport manager has to choose between a number of full truck load pick-ups and deliveries on a road network where travel times change...

  11. Arc deflection model and arc direction control for DC arc furnace

    Institute of Scientific and Technical Information of China (English)

    Liping Wei; Huang Zhou; Huade Li; Yuanhang Zhou

    2004-01-01

    Based on the analysis of three-dimensional power conductor for DC arc furnace, the electric arc deflection model was set up and the control system of the arc direction was configured. According to the bus bar distribution at the bottom electrodes cooled by water, the arc direction control principle and its configuration were described. The simulation results show that the control system can restrain the electric arc deflection and control the arc direction.

  12. Volumetric modulated arc therapy versus step-and-shoot intensity modulated radiation therapy in the treatment of large nerve perineural spread to the skull base: a comparative dosimetric planning study

    Energy Technology Data Exchange (ETDEWEB)

    Gorayski, Peter; Fitzgerald, Rhys; Barry, Tamara [Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Queensland (Australia); Burmeister, Elizabeth [Nursing Practice Development Unit, Princess Alexandra Hospital and Research Centre for Clinical and Community Practice Innovation, Griffith University, Brisbane, Queensland (Australia); Foote, Matthew [Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Queensland (Australia); Diamantina Institute, University of Queensland, Brisbane, Queensland (Australia)

    2014-06-15

    Cutaneous squamous cell carcinoma with large nerve perineural (LNPN) infiltration of the base of skull is a radiotherapeutic challenge given the complex target volumes to nearby organs at risk (OAR). A comparative planning study was undertaken to evaluate dosimetric differences between volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) in the treatment of LNPN. Five consecutive patients previously treated with IMRT for LNPN were selected. VMAT plans were generated for each case using the same planning target volumes (PTV), dose prescriptions and OAR constraints as IMRT. Comparative parameters used to assess target volume coverage, conformity and homogeneity included V95 of the PTV (volume encompassed by the 95% isodose), conformity index (CI) and homogeneity index (HI). In addition, OAR maximum point doses, V20, V30, non-target tissue (NTT) point max doses, NTT volume above reference dose, monitor units (MU) were compared. IMRT and VMAT plans generated were comparable for CI (P = 0.12) and HI (P = 0.89). VMAT plans achieved better V95 (P = < 0.001) and reduced V20 and V30 by 652 cubic centimetres (cc) (28.5%) and 425.7 cc (29.1%), respectively. VMAT increased MU delivered by 18% without a corresponding increase in NTT dose. Compared with IMRT plans for LNPN, VMAT achieved comparable HI and CI.

  13. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ%≤1, γavg < 0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  14. Volumetric modulated arc therapy versus step-and-shoot intensity modulated radiation therapy in the treatment of large nerve perineural spread to the skull base: a comparative dosimetric planning study

    International Nuclear Information System (INIS)

    Cutaneous squamous cell carcinoma with large nerve perineural (LNPN) infiltration of the base of skull is a radiotherapeutic challenge given the complex target volumes to nearby organs at risk (OAR). A comparative planning study was undertaken to evaluate dosimetric differences between volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) in the treatment of LNPN. Five consecutive patients previously treated with IMRT for LNPN were selected. VMAT plans were generated for each case using the same planning target volumes (PTV), dose prescriptions and OAR constraints as IMRT. Comparative parameters used to assess target volume coverage, conformity and homogeneity included V95 of the PTV (volume encompassed by the 95% isodose), conformity index (CI) and homogeneity index (HI). In addition, OAR maximum point doses, V20, V30, non-target tissue (NTT) point max doses, NTT volume above reference dose, monitor units (MU) were compared. IMRT and VMAT plans generated were comparable for CI (P = 0.12) and HI (P = 0.89). VMAT plans achieved better V95 (P = < 0.001) and reduced V20 and V30 by 652 cubic centimetres (cc) (28.5%) and 425.7 cc (29.1%), respectively. VMAT increased MU delivered by 18% without a corresponding increase in NTT dose. Compared with IMRT plans for LNPN, VMAT achieved comparable HI and CI

  15. Tokamak ARC damage

    International Nuclear Information System (INIS)

    Tokamak fusion reactors will have large plasma currents of approximately 10 MA with hundreds of megajoules stored in the magnetic fields. When a major plasma instability occurs, the disruption of the plasma current induces voltage in the adjacent conducting structures, giving rise to large transient currents. The induced voltages may be sufficiently high to cause arcing across sector gaps or from one protruding component to another. This report reviews a tokamak arcing scenario and provides guidelines for designing tokamaks to minimize the possibility of arc damage

  16. Radiation-induced second primary cancer risks from modern external beam radiotherapy for early prostate cancer: impact of stereotactic ablative radiotherapy (SABR), volumetric modulated arc therapy (VMAT) and flattening filter free (FFF) radiotherapy

    Science.gov (United States)

    Murray, Louise J.; Thompson, Christopher M.; Lilley, John; Cosgrove, Vivian; Franks, Kevin; Sebag-Montefiore, David; Henry, Ann M.

    2015-02-01

    Risks of radiation-induced second primary cancer following prostate radiotherapy using 3D-conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), flattening filter free (FFF) and stereotactic ablative radiotherapy (SABR) were evaluated. Prostate plans were created using 10 MV 3D-CRT (78 Gy in 39 fractions) and 6 MV 5-field IMRT (78 Gy in 39 fractions), VMAT (78 Gy in 39 fractions, with standard flattened and energy-matched FFF beams) and SABR (42.7 Gy in 7 fractions with standard flattened and energy-matched FFF beams). Dose-volume histograms from pelvic planning CT scans of three prostate patients, each planned using all 6 techniques, were used to calculate organ equivalent doses (OED) and excess absolute risks (EAR) of second rectal and bladder cancers, and pelvic bone and soft tissue sarcomas, using mechanistic, bell-shaped and plateau models. For organs distant to the treatment field, chamber measurements recorded in an anthropomorphic phantom were used to calculate OEDs and EARs using a linear model. Ratios of OED give relative radiation-induced second cancer risks. SABR resulted in lower second cancer risks at all sites relative to 3D-CRT. FFF resulted in lower second cancer risks in out-of-field tissues relative to equivalent flattened techniques, with increasing impact in organs at greater distances from the field. For example, FFF reduced second cancer risk by up to 20% in the stomach and up to 56% in the brain, relative to the equivalent flattened technique. Relative to 10 MV 3D-CRT, 6 MV IMRT or VMAT with flattening filter increased second cancer risks in several out-of-field organs, by up to 26% and 55%, respectively. For all techniques, EARs were consistently low. The observed large relative differences between techniques, in absolute terms, were very low, highlighting the importance of considering absolute risks alongside the corresponding relative risks, since when absolute

  17. Dynamic electron arc radiotherapy (DEAR): a feasibility study

    International Nuclear Information System (INIS)

    Compared to other radiation therapy modalities, clinical electron beam therapy has remained practically unchanged for the past few decades even though electron beams with multiple energies are widely available on most linacs. In this paper, we present the concept of dynamic electron arc radiotherapy (DEAR), a new conformal electron therapy technique with synchronized couch motion. DEAR utilizes combination of gantry rotation, couch motion, and dose rate modulation to achieve desirable dose distributions in patient. The electron applicator is kept to minimize scatter and maintain narrow penumbra. The couch motion is synchronized with the gantry rotation to avoid collision between patient and the electron cone. In this study, we investigate the feasibility of DEAR delivery and demonstrate the potential of DEAR to improve dose distributions on simple cylindrical phantoms. DEAR was delivered on Varian's TrueBeam linac in Research Mode. In conjunction with the recorded trajectory log files, mechanical motion accuracies and dose rate modulation precision were analyzed. Experimental and calculated dose distributions were investigated for different energies (6 and 9 MeV) and cut-out sizes (1×10 cm2 and 3×10 cm2 for a 15×15 cm2 applicator). Our findings show that DEAR delivery is feasible and has the potential to deliver radiation dose with high accuracy (root mean square error, or RMSE of <0.1 MU, <0.1° gantry, and <0.1 cm couch positions) and good dose rate precision (1.6 MU min−1). Dose homogeneity within ±2% in large and curved targets can be achieved while maintaining penumbra comparable to a standard electron beam on a flat surface. Further, DEAR does not require fabrication of patient-specific shields. These benefits make DEAR a promising technique for conformal radiotherapy of superficial tumors. (paper)

  18. Single Arc Volumetric Modulated Arc Therapy of head and neck cancer

    DEFF Research Database (Denmark)

    Bertelsen, Anders; Hansen, Christian Rønn; Johansen, Jørgen;

    2010-01-01

    BACKGROUND: The quality of Volumetric Modulated Arc Therapy (VMAT) plans is highly dependent on the performance of the optimization algorithm used. Recently new algorithms have become available which are capable of generating VMAT plans for Elekta accelerators. The VMAT algorithm in Pinnacle...... is named SmartArc and its capability to generate treatment plans for head and neck cancer was tested. METHODS: Twenty-five patients with oropharyngeal or hypopharyngeal carcinoma, previously treated with IMRT by means of Pinnacle and Elekta accelerators, were replanned with single arc VMAT. The VMAT...... planning objectives were to achieve clinical target coverage and sparing of the organs at risk (OAR). Comparison with the original clinically used IMRT was made by evaluating (1) dose-volume histograms (DVHs) for PTVs, (2) DVHs for OARs, (3) delivery time and monitor units (MU), and (4) treatment accuracy...

  19. Hydration characteristics of water in radiation polymerized hema-co- ionomeric controlled drug delivery matrices: a DSC study

    International Nuclear Information System (INIS)

    The changes in the bulk (freezable) and bound (non-freezable) water contents of radiation polymerized (2-hydroxy ethyl methacrylate) (PHEMA) containing two different types of ionomers have been studied by differential scanning calorimetry (DSC). It was found that introduction of 5-10% of acrylic acid into PHEMA matrix affects mainly the bulk water content whereas introduction of sodium para styrene sulphonate affects both types of water significantly. (author)

  20. ALICE - ARC integration

    OpenAIRE

    Anderlik, Csaba; Gregersen, Anders Rhod; Kleist, Josva; Peters, Andreas; Siaz, Pablo

    2007-01-01

    AliEn or Alice Environment is the Gridware developed and used within the ALICE collaboration for storing and processing data in a distributed manner. ARC (Advanced Resource Connector) is the Grid middleware deployed across the Nordic countries and gluing together the resources within the Nordic Data Grid Facility (NDGF). In this paper we will present our approach to integrate AliEn and ARC, in the sense that ALICE data management and job processing can be carried out on the NDGF infrastructur...

  1. Optimal partial-arcs in VMAT treatment planning

    CERN Document Server

    Wala, Jeremiah; Chen, Wei; Craft, David

    2012-01-01

    Purpose: To improve the delivery efficiency of VMAT by extending the recently published VMAT treatment planning algorithm vmerge to automatically generate optimal partial-arc plans. Methods and materials: A high-quality initial plan is created by solving a convex multicriteria optimization problem using 180 equi-spaced beams. This initial plan is used to form a set of dose constraints, and a set of partial-arc plans is created by searching the space of all possible partial-arc plans that satisfy these constraints. For each partial-arc, an iterative fluence map merging and sequencing algorithm (vmerge) is used to improve the delivery efficiency. Merging continues as long as the dose quality is maintained above a user-defined threshold. The final plan is selected as the partial arc with the lowest treatment time. The complete algorithm is called pmerge. Results: Partial-arc plans are created using pmerge for a lung, liver and prostate case, with final treatment times of 127, 245 and 147 seconds. Treatment times...

  2. Radiation

    International Nuclear Information System (INIS)

    The basic facts about radiation are explained, along with some simple and natural ways of combating its ill-effects, based on ancient healing wisdom as well as the latest biochemical and technological research. Details are also given of the diet that saved thousands of lives in Nagasaki after the Atomic bomb attack. Special comment is made on the use of radiation for food processing. (U.K.)

  3. Commissioning and quality assurance of Dynamic WaveArc irradiation.

    Science.gov (United States)

    Sato, Sayaka; Miyabe, Yuki; Takahashi, Kunio; Yamada, Masahiro; Nakamura, Mitsuhiro; Ishihara, Yoshitomo; Yokota, Kenji; Kaneko, Shuji; Mizowaki, Takashi; Monzen, Hajime; Hiraoka, Masahiro

    2015-01-01

    A novel three-dimensional unicursal irradiation technique "Dynamic WaveArc" (DWA), which employs simultaneous and continuous gantry and O-ring rotation during dose delivery, has been implemented in Vero4DRT. The purposes of this study were to develop a commissioning and quality assurance procedure for DWA irradiation, and to assess the accuracy of the mechanical motion and dosimetric control of Vero4DRT. To determine the mechanical accuracy and the dose accuracy with DWA irradiation, 21 verification test patterns with various gantry and ring rotational directions and speeds were generated. These patterns were irradiated while recording the irradiation log data. The differences in gantry position, ring position, and accumulated MU (EG, ER, and EMU, respectively) between the planned and actual values in the log at each time point were evaluated. Furthermore, the doses delivered were measured using an ionization chamber and spherical phantom. The constancy of radiation output during DWA irradiation was examined by comparison with static beam irradiation. The mean absolute error (MAE) of EG and ER were within 0.1° and the maximum error was within 0.2°. The MAE of EMU was within 0.7 MU, and maximum error was 2.7 MU. Errors of accumulated MU were observed only around control points, changing gantry, and ring velocity. The gantry rotational range, in which EMU was greater than or equal to 2.0 MU, was not greater than 3.2%. It was confirmed that the extent of the large differences in accumulated MU was negligibly small during the entire irradiation range. The variation of relative output value for DWA irradiation was within 0.2%, and this was equivalent to conventional arc irradiation with a rotating gantry. In conclusion, a verification procedure for DWA irradiation was designed and implemented. The results demonstrated that Vero4DRT has adequate mechanical accuracy and beam output constancy during gantry and ring rotation. PMID:26103177

  4. Flexible delivery of Er:YAG radiation at 2.94 μm with novel hollow-core silica glass fibres: demonstration of tissue ablation

    Science.gov (United States)

    Urich, Artur; Maier, Robert R. J.; Knight, Jonathan C.; Yu, Fei; Hand, Duncan P.; Shephard, Jonathan D.

    2013-03-01

    In this work we present the delivery of high energy Er:YAG laser pulses operating at 2.94 μm through a hollow-core negative curvature fibre (HC-NCF) and a hollow-core photonic crystal fibre (HC-PCF) and their use for the ablation of biological tissue. In HC-NCF fibres, which have been developed recently, the laser radiation is confined in a hollow core and by an anti-resonant or reflection principle (also known as ARROW). Both fibres are made of fused silica which has high mechanical and chemical durability, is bio-inert and results in a fibre with the flexibility that lends itself to easy handling and minimally invasive procedures. The HC-NCF structure consists of only one ring of capillaries around a realtively large core, followed by a protecting outer layer, hence the preform is relatively easy to build compared to traditional HC-PCF. The measured attenuation at 2.94 μm is 0.06 dB/m for the HC-NCF and 1.2 dB/m for the HC-PCF. Both fibres have a single mode output beam profile which can be advantageous for surgical applications as the beam profile is maintained during fibre movement. We demonstrate delivery of high energy pulses through both fibres, well above the thresholds needed for the ablation of biological tissue in non-contact and contact mode. Delivered energy densities reached > 750 J/cm-2 after 10 m of HC-NCF and > 3400 J/cm2 through a 44 cm HC-PCF.

  5. SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Omari, E; Noid, G; Ehlers, C; Erickson, B; Quiroz, F; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States); Cooper, D; Lachaine, M [Elekta Inc., Stockholm (Sweden)

    2015-06-15

    Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by

  6. Theory of Parabolic Arcs in Interstellar Scintillation Spectra

    CERN Document Server

    Cordes, J M; Stinebring, D R; Coles, W A; Cordes, James M.; Rickett, Barney J.; Stinebring, Daniel R.; Coles, William A.

    2004-01-01

    Our theory relates the secondary spectrum, the 2D power spectrum of the radio dynamic spectrum, to the scattered pulsar image in a thin scattering screen geometry. Recently discovered parabolic arcs in secondary spectra are generic features for media that scatter radiation at angles much larger than the rms scattering angle. Each point in the secondary spectrum maps particular values of differential arrival-time delay and fringe rate (or differential Doppler frequency) between pairs of components in the scattered image. Arcs correspond to a parabolic relation between these quantities through their common dependence on the angle of arrival of scattered components. Arcs appear even without consideration of the dispersive nature of the plasma. Arcs are more prominent in media with negligible inner scale and with shallow wavenumber spectra, such as the Kolmogorov spectrum, and when the scattered image is elongated along the velocity direction. The arc phenomenon can be used, therefore, to constrain the inner scal...

  7. Modeling of Arc Force in Plasma Arc Welding

    Institute of Scientific and Technical Information of China (English)

    GAO Zhonglin; HU Shengsun; YIN Fengliang; WANG Rui

    2008-01-01

    A three. dimensional mathematical model for the transferred-type argon arc was developed to describe arc force on the anode surface. The software ANSYS was employed to solve the model. The model includes a part of torch and tungsten electrode to achieve m ore reasonable results. The arc temperature and flow fields were derived. And the influences of welding parameters on arc force were also studied. The simulated results show that arc pressure at the anode are dependent on the welding current, plasma gas flow rate and electrode neck-in, while not sensitive to arc length.

  8. ALICE-ARC integration

    International Nuclear Information System (INIS)

    AliEn or Alice Environment is the Grid middleware developed and used within the ALICE collaboration for storing and processing data in a distributed manner. ARC (Advanced Resource Connector) is the Grid middleware deployed across the Nordic countries and gluing together the resources within the Nordic Data Grid Facility (NDGF). In this paper we will present our approach to integrate AliEn and ARC, in the sense that ALICE data management and job processing can be carried out on the NDGF infrastructure, using the client tools available in AliEn. The inter-operation has two aspects, one is the data management part and the second the job management aspect. The first aspect was solved by using dCache across NDGF to handle data. Therefore, we will concentrate on the second part. Solving it, was somewhat cumbersome, mainly due to the different computing models employed by AliEn and ARC. AliEN uses an Agent based pull model while ARC handles jobs through the more 'traditional' push model. The solution comes as a module implementing the functionalities necessary to achieve AliEn job submission and management to ARC enabled sites

  9. Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer.

    Science.gov (United States)

    Balderson, Michael; Brown, Derek; Johnson, Patricia; Kirkby, Charles

    2016-01-01

    The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic-based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT. PMID:27067229

  10. MODELING PARAMETERS OF ARC OF ELECTRIC ARC FURNACE

    Directory of Open Access Journals (Sweden)

    R.N. Khrestin

    2015-08-01

    Full Text Available Purpose. The aim is to build a mathematical model of the electric arc of arc furnace (EAF. The model should clearly show the relationship between the main parameters of the arc. These parameters determine the properties of the arc and the possibility of optimization of melting mode. Methodology. We have built a fairly simple model of the arc, which satisfies the above requirements. The model is designed for the analysis of electromagnetic processes arc of varying length. We have compared the results obtained when testing the model with the results obtained on actual furnaces. Results. During melting in real chipboard under the influence of changes in temperature changes its properties arc plasma. The proposed model takes into account these changes. Adjusting the length of the arc is the main way to regulate the mode of smelting chipboard. The arc length is controlled by the movement of the drive electrode. The model reflects the dynamic changes in the parameters of the arc when changing her length. We got the dynamic current-voltage characteristics (CVC of the arc for the different stages of melting. We got the arc voltage waveform and identified criteria by which possible identified stage of smelting. Originality. In contrast to the previously known models, this model clearly shows the relationship between the main parameters of the arc EAF: arc voltage Ud, amperage arc id and length arc d. Comparison of the simulation results and experimental data obtained from real particleboard showed the adequacy of the constructed model. It was found that character of change of magnitude Md, helps determine the stage of melting. Practical value. It turned out that the model can be used to simulate smelting in EAF any capacity. Thus, when designing the system of control mechanism for moving the electrode, the model takes into account changes in the parameters of the arc and it can significantly reduce electrode material consumption and energy consumption

  11. Early clinical experience of radiotherapy of prostate cancer with volumetric modulated arc therapy

    Directory of Open Access Journals (Sweden)

    Valli Mariacarla

    2010-06-01

    Full Text Available Abstract Background To report about initial clinical experience in radiation treatment of carcinoma of prostate with volumetric modulated arcs with the RapidArc (RA technology. Methods Forty-five patients with a median age of 72 ± 3, affected by prostate carcinoma (T1c: 22 patients, T2a-b: 17 patients, T3a-b: 6 patients. N0: 43 patients, N1-Nx: 2 patients, all M0, with initial PSA of 10.0 ± 3.0 ng/mL, were treated with RapidArc in a feasibility study. All patients were treated with single arc using 6MV photons. Dose prescription ranged between 76 (7 patients and 78 Gy (38 patients in 2Gy/fraction. Plan quality was assessed by means of Dose Volume Histogram (DVH analysis. Technical parameters of arcs and pre-treatment quality assurance results (Gamma Agreement Index, GAI are reported to describe delivery features. Early toxicity was scored (according to the Common Terminology Criteria of Adverse Effects scale, CTCAE, scale at the end of treatment together with biochemical outcome (PSA. Results From DVH data, target coverage was fulfilling planning objectives: V95% was in average higher than 98% and V107%~0.0% (D2%~104.0% in average. Homogeneity D5%-D95% ranged between 6.2 ± 1.0% to 6.7 ± 1.3%. For rectum, all planning objectives were largely met (e.g. V70Gy = 10.7 ± 5.5% against an objective of 2% = 79.4 ± 1.2Gy against an objective of 80.0Gy. Maximum dose to femurs was D2% = 36.7 ± 5.4Gy against an objective of 47Gy. Monitor Units resulted: MU/Gy = 239 ± 37. Average beam on time was 1.24 ± 0.0 minutes. Pre-treatment GAI resulted in 98.1 ± 1.1%. Clinical data were recorded as PSA at 6 weeks after RT, with median values of 0.4 ± 0.4 ng/mL. Concerning acute toxicity, no patient showed grade 2-3 rectal toxicity; 5/42 (12% patients experienced grade 2 dysuria; 18/41 (44% patients preserved complete or partial erectile function. Conclusion RapidArc proved to be a safe, qualitative and advantageous treatment modality for prostate cancer.

  12. Designing tragacanth gum based sterile hydrogel by radiation method for use in drug delivery and wound dressing applications.

    Science.gov (United States)

    Singh, Baljit; Varshney, Lalit; Francis, Sanju; Rajneesh

    2016-07-01

    Present article discusses synthesis and characterization of the sterile and pure hydrogel wound dressings which were prepared through radiation method by using polyvinyl alcohol (PVA), tragacanth gum (TG) and sodium alginate (SA). The polymer films were characterized by SEM, Cryo-SEM, FTIR, solid state C(13) NMR and XRD, TGA, and DSC. Some important biological properties such as O2 permeability, water vapor transmission rate, microbial permeability, haemolysis, thrombogenic behavior, antioxidant activity, bio-adhesion and mechanical properties were also studied. The hydrogel film showed thrombogenicity (82.43±1.54%), haemolysis (0.83±0.09%), oxygen permeability (6.433±0.058mg/L) and water vapor permeability (197.39±25.34g/m(2)/day). Hydrogel films were found biocompatible and impermeable to microbes. The release of antibiotic drug moxifloxacin occurred through non-Fickian mechanism and release profile was best fitted in Hixson-Crowell model for drug release. Overall, these results indicate the suitability of these hydrogels in wound dressing applications. PMID:27020943

  13. Detailed analysis of multi-leaf collimator movement during radiation delivery using an in-house-developed program

    International Nuclear Information System (INIS)

    Multi-leaf collimators (MLCs) are used to modulate intensity during intensity modulated radiation therapy (IMRT). Evaluation of MLC movement in IMRT is important, since the accuracy of MLC movements affects the dose distribution. This evaluation is conventionally performed using an attached Dynalog File Viewer (DFV). However, due to its being an overall evaluation, it is not possible to discover significant errors. In this study, we developed software that permits easy analysis of MLC movements that can be used to retrospectively evaluate MLC movement during irradiation. We also evaluated the usefulness of our in-house program and confirmed its potential for use in clinical scenarios. We created a program that can read MLC logfiles using Visual Basic 6.0 and visualize the temporal changes and movements of the MLC. To evaluate our in-house program's efficacy in analyzing dynamic MLC-QA (quality assurance), we compared the numerical results yielded by our in-house program and the DFV. The results showed that our in-house program was able to reveal errors below the error root mean square (RMS) values obtained using the DFV. Using irregular surface compensator (ISC) irradiation conditions in a clinical context, we compared our in-house program with the DFV and, using RMS analysis, identified cases that showed excessive error. Our in-house program can also be used to investigate whether unacceptable errors are present, as well as their cause, when using the MLC, as it allows easy real-time observation and evaluation of MLC movements. An additional benefit is that collecting the MLC logfile during actual treatment also allows it to be evaluated retrospectively after continuous MLC operation. (author)

  14. The Effect of Flattening Filter Free on Three-dimensional Conformal Radiation Therapy (3D-CRT), Intensity-Modulated Radiation Therapy (IMRT), and Volumetric Modulated Arc Therapy (VMAT) Plans for Metastatic Brain Tumors from Non-small Cell Lung Cancer.

    Science.gov (United States)

    Shi, Li-Wan; Lai, You-Qun; Lin, Qin; Ha, Hui-Ming; Fu, Li-Rong

    2015-07-01

    Flattening filter free (FFF) may affect outcome measures of radiotherapy. The objective of this study is to compare the dosimetric parameters in three types of radiotherapy plans, three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT), with or without the flattening filter (FF), developed for the treatment of metastatic brain tumors from non-small cell lung cancer (NSCLC). From July 2013 to October 2013, 3D-CRT, IMRT, and VMAT treatment plans were designed using 6 MV and 10 MV, with and without FF, for 10 patients with brain metastasis from NSCLC. The evaluation of the treatment plans included homogeneity index (HI), conformity index (CI), monitor units (MU), mean dose (Dmean), treatment time, and the influence of FFF on volumes. There was no difference in CI or HI between FFF and FF models with 3D-CRT, IMRT, and VMAT plans. At 6 MV, a lower Dmean was seen in the FFF model of 3D-CRT and in the VMAT plan at 10 MV. In the IMRT 6 MV, IMRT 10 MV, and VMAT 10 MV plans, higher MUs were seen in the FFF models. FFF treatments are similar in quality to FF plans, generally lead to more monitor units, and are associated with shorter treatment times. FFF plans ranked by the order of superiority in terms of a time advantage are VMAT, 3D-CRT, and IMRT. PMID:26011493

  15. The Effect of Flattening Filter Free on Three-dimensional Conformal Radiation Therapy (3D-CRT), Intensity-Modulated Radiation Therapy (IMRT), and Volumetric Modulated Arc Therapy (VMAT) Plans for Metastatic Brain Tumors from Non-small Cell Lung Cancer.

    Science.gov (United States)

    Shi, Li-Wan; Lai, You-Qun; Lin, Qin; Ha, Hui-Ming; Fu, Li-Rong

    2015-07-01

    Flattening filter free (FFF) may affect outcome measures of radiotherapy. The objective of this study is to compare the dosimetric parameters in three types of radiotherapy plans, three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT), with or without the flattening filter (FF), developed for the treatment of metastatic brain tumors from non-small cell lung cancer (NSCLC). From July 2013 to October 2013, 3D-CRT, IMRT, and VMAT treatment plans were designed using 6 MV and 10 MV, with and without FF, for 10 patients with brain metastasis from NSCLC. The evaluation of the treatment plans included homogeneity index (HI), conformity index (CI), monitor units (MU), mean dose (Dmean), treatment time, and the influence of FFF on volumes. There was no difference in CI or HI between FFF and FF models with 3D-CRT, IMRT, and VMAT plans. At 6 MV, a lower Dmean was seen in the FFF model of 3D-CRT and in the VMAT plan at 10 MV. In the IMRT 6 MV, IMRT 10 MV, and VMAT 10 MV plans, higher MUs were seen in the FFF models. FFF treatments are similar in quality to FF plans, generally lead to more monitor units, and are associated with shorter treatment times. FFF plans ranked by the order of superiority in terms of a time advantage are VMAT, 3D-CRT, and IMRT.

  16. Thermal Arc Spray Overview

    Science.gov (United States)

    Hafiz Abd Malek, Muhamad; Hayati Saad, Nor; Kiyai Abas, Sunhaji; Mohd Shah, Noriyati

    2013-06-01

    Usage of protective coating for corrosion protection was on highly demand during the past decade; and thermal spray coating played a major part during that time. In recent years, the thermal arc spray coating becomes a popular coating. Many big players in oil and gas such as PETRONAS, EXXON MOBIL and SHELL in Malaysia tend to use the coating on steel structure as a corrosion protection. Further developments in coating processes, the devices, and raw materials have led to expansion of functional coatings and applications scope from conventional coating to specialized industries. It is widely used because of its ability to withstand high process temperature, offer advantages in efficiency, lower cost and acts as a corrosion protection. Previous research also indicated that the thermal arc spray offers better coating properties compared to other methods of spray. This paper reviews some critical area of thermal spray coating by discussing the process/parameter of thermal arc spray technology and quality control of coating. Coating performance against corrosion, wear and special characteristic of coating are also described. The field application of arc spray technology are demonstrated and reviewed.

  17. ALICE: ARC integration

    CERN Document Server

    Anderlik, C; Kleist, J; Peters, A; Saiz, P

    2008-01-01

    AliEn or Alice Environment is the Grid middleware developed and used within the ALICE collaboration for storing and processing data in a distributed manner. ARC (Advanced Resource Connector) is the Grid middleware deployed across the Nordic countries and gluing together the resources within the Nordic Data Grid Facility (NDGF). In this paper we will present our approach to integrate AliEn and ARC, in the sense that ALICE data management and job processing can be carried out on the NDGF infrastructure, using the client tools available in AliEn. The inter-operation has two aspects, one is the data management part and the second the job management aspect. The first aspect was solved by using dCache across NDGF to handle data. Therefore, we will concentrate on the second part. Solving it, was somewhat cumbersome, mainly due to the different computing models employed by AliEn and ARC. AliEN uses an Agent based pull model while ARC handles jobs through the more 'traditional' push model. The solution comes as a modu...

  18. Optimal set of grid size and angular increment for practical dose calculation using the dynamic conformal arc technique: a systematic evaluation of the dosimetric effects in lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    To recommend the optimal plan parameter set of grid size and angular increment for dose calculations in treatment planning for lung stereotactic body radiation therapy (SBRT) using dynamic conformal arc therapy (DCAT) considering both accuracy and computational efficiency. Dose variations with varying grid sizes (2, 3, and 4 mm) and angular increments (2°, 4°, 6°, and 10°) were analyzed in a thorax phantom for 3 spherical target volumes and in 9 patient cases. A 2-mm grid size and 2° angular increment are assumed sufficient to serve as reference values. The dosimetric effect was evaluated using dose–volume histograms, monitor units (MUs), and dose to organs at risk (OARs) for a definite volume corresponding to the dose–volume constraint in lung SBRT. The times required for dose calculations using each parameter set were compared for clinical practicality. Larger grid sizes caused a dose increase to the structures and required higher MUs to achieve the target coverage. The discrete beam arrangements at each angular increment led to over- and under-estimated OARs doses due to the undulating dose distribution. When a 2° angular increment was used in both studies, a 4-mm grid size changed the dose variation by up to 3–4% (50 cGy) for the heart and the spinal cord, while a 3-mm grid size produced a dose difference of <1% (12 cGy) in all tested OARs. When a 3-mm grid size was employed, angular increments of 6° and 10° caused maximum dose variations of 3% (23 cGy) and 10% (61 cGy) in the spinal cord, respectively, while a 4° increment resulted in a dose difference of <1% (8 cGy) in all cases except for that of one patient. The 3-mm grid size and 4° angular increment enabled a 78% savings in computation time without making any critical sacrifices to dose accuracy. A parameter set with a 3-mm grid size and a 4° angular increment is found to be appropriate for predicting patient dose distributions with a dose difference below 1% while reducing the

  19. Accelerated partial breast irradiation: Using the CyberKnife as the radiation delivery platform in the treatment of early breast cancer

    Directory of Open Access Journals (Sweden)

    Sandra eVermeulen

    2011-11-01

    Full Text Available We evaluate the CyberKnife (Accuray, Incorporated, Sunnyvale, CA for non-invasive delivery of accelerated partial breast irradiation (APBI in early breast cancer patients. Between 6/2009 and 5/2011, 9 patients were treated with CyberKnife APBI. Normal tissue constraints were imposed as outlined in the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 (NSABP/RTOG Protocol (Vicini and White, 2007. Patients received a total dose of 30 Gy in 5 fractions (group 1, n=2 or 34 Gy in 10 fractions (group 2, n=7 delivered to the planning treatment volume (PTV defined as the clinical target volume (CTV + 2 mm. The CTV was defined as either the lumpectomy cavity plus 10 mm (n=2 or 15 mm (n=7. The cavity was defined by a T2-weighted non-contrast breast MRI fused to a planning non-contrast thoracic CT. The CyberKnife Synchrony system tracked gold fiducials sutured into the cavity wall during lumpectomy. Treatments started 4-5 weeks after lumpectomy. The mean PTV was 100 cm3 (range, 92-108 cm3 and 105 cm3 (range, 49-241 cm3 and the mean PTV isodose prescription line was 70% for groups 1 and 2, respectively. The mean percent of whole breast reference volume receiving 100% and 50% of the dose (V100 and V50 for group 1 was 11% (range, 8-13% and 23% (range, 16-30% and for group 2 was 11% (range, 7-14% and 26% (range, 21- 35.0% , respectively. At a median 7 months follow-up (range, 4-26 months, no acute toxicities were seen. Acute cosmetic outcomes were excellent or good in all patients; for those patients with more than 12 months follow-up the late cosmesis outcomes were excellent or good. In conclusion, the lack of observable acute side effects and current excellent/good cosmetic outcomes is promising. We believe this suggests the CyberKnife is a suitable non-invasive radiation platform for delivering APBI with achievable normal tissue constraints.

  20. Semicircular Rashba arc spin polarizer

    Energy Technology Data Exchange (ETDEWEB)

    Bin Siu, Zhuo, E-mail: a0018876@nus.edu.sg [NUS Graduate School for Integrative Sciences and Engineering, National University of Singapore, Singapore 117456 (Singapore); Advanced Concepts and Nanotechnology, Data Storage Institute, DSI Building, 5 Engineering Drive 1 (Off Kent Ridge Crescent, NUS), Singapore 117608 (Singapore); Jalil, Mansoor B. A. [NUS Graduate School for Integrative Sciences and Engineering, National University of Singapore, Singapore 117456 (Singapore); Ghee Tan, Seng [Advanced Concepts and Nanotechnology, Data Storage Institute, DSI Building, 5 Engineering Drive 1 (Off Kent Ridge Crescent, NUS), Singapore 117608 (Singapore)

    2014-05-07

    In this work, we study the generation of spin polarized currents using curved arcs of finite widths, in which the Rashba spin orbit interaction (RSOI) is present. Compared to the 1-dimensional RSOI arcs with zero widths studied previously, the finite width presents charge carriers with another degree of freedom along the transverse width of the arc, in addition to the longitudinal degree of freedom along the circumference of the arc. The asymmetry in the transverse direction due to the difference in the inner and outer radii of the arc breaks the antisymmetry of the longitudinal spin z current in a straight RSOI segment. This property can be exploited to generate spin z polarized current output from the RSOI arc by a spin unpolarized current input. The sign of the spin current can be manipulated by varying the arc dimensions.

  1. ALICE-ARC integration

    DEFF Research Database (Denmark)

    Anderlik, Csaba; Gregersen, Anders Rhod; Kleist, Josva;

    2008-01-01

    Data Grid Facility (NDGF). In this paper we will present our approach to integrate AliEn and ARC, in the sense that ALICE data management and job processing can be carried out on the NDGF infrastructure, using the client tools available in AliEn. The interoperation has two aspects, one is the data......AliEn or Alice Environment is the Gridware developed and used within the ALICE collaboration for storing and processing data in a distributed manner. ARC (Advanced Resource Connector) is the Grid middleware deployed across the Nordic countries and gluing together the resources within the Nordic...... management part and the second the job management aspect. The first aspect was solved by using dCache across NDGF to handle data. dCache provides support for several data management tools (among them for xrootd the tools used by AliEn) using the so called "doors". Therefore, we will concentrate on the second...

  2. ALICE - ARC integration

    DEFF Research Database (Denmark)

    Anderlik, Csaba; Gregersen, Anders Rhod; Kleist, Josva;

    Data Grid Facility (NDGF). In this paper we will present our approach to integrate AliEn and ARC, in the sense that ALICE data management and job processing can be carried out on the NDGF infrastructure, using the client tools available in AliEn. The interoperation has two aspects, one is the data......AliEn or Alice Environment is the Gridware developed and used within the ALICE collaboration for storing and processing data in a distributed manner. ARC (Advanced Resource Connector) is the Grid middleware deployed across the Nordic countries and gluing together the resources within the Nordic...... management part and the second the job management aspect. The first aspect was solved by using dCache across NDGF to handle data. dCache provides support for several data management tools (among them for xrootd the tools used by AliEn) using the so called "doors". Therefore, we will concentrate on the second...

  3. Vacuum Arc Ion Sources

    OpenAIRE

    Brown, I.

    2014-01-01

    The vacuum arc ion source has evolved into a more or less standard laboratory tool for the production of high-current beams of metal ions, and is now used in a number of different embodiments at many laboratories around the world. Applications include primarily ion implantation for material surface modification research, and good performance has been obtained for the injection of high-current beams of heavy-metal ions, in particular uranium, into particle accelerators. As the use of the sourc...

  4. Circular arc structures

    KAUST Repository

    Bo, Pengbo

    2011-07-01

    The most important guiding principle in computational methods for freeform architecture is the balance between cost efficiency on the one hand, and adherence to the design intent on the other. Key issues are the simplicity of supporting and connecting elements as well as repetition of costly parts. This paper proposes so-called circular arc structures as a means to faithfully realize freeform designs without giving up smooth appearance. In contrast to non-smooth meshes with straight edges where geometric complexity is concentrated in the nodes, we stay with smooth surfaces and rather distribute complexity in a uniform way by allowing edges in the shape of circular arcs. We are able to achieve the simplest possible shape of nodes without interfering with known panel optimization algorithms. We study remarkable special cases of circular arc structures which possess simple supporting elements or repetitive edges, we present the first global approximation method for principal patches, and we show an extension to volumetric structures for truly threedimensional designs. © 2011 ACM.

  5. Arc-preserving subsequences of arc-annotated sequences

    CERN Document Server

    Popov, Vladimir Yu

    2011-01-01

    Arc-annotated sequences are useful in representing the structural information of RNA and protein sequences. The longest arc-preserving common subsequence problem has been introduced as a framework for studying the similarity of arc-annotated sequences. In this paper, we consider arc-annotated sequences with various arc structures. We consider the longest arc preserving common subsequence problem. In particular, we show that the decision version of the 1-{\\sc fragment LAPCS(crossing,chain)} and the decision version of the 0-{\\sc diagonal LAPCS(crossing,chain)} are {\\bf NP}-complete for some fixed alphabet $\\Sigma$ such that $|\\Sigma| = 2$. Also we show that if $|\\Sigma| = 1$, then the decision version of the 1-{\\sc fragment LAPCS(unlimited, plain)} and the decision version of the 0-{\\sc diagonal LAPCS(unlimited, plain)} are {\\bf NP}-complete.

  6. Modeling treatment couches in the Pinnacle treatment planning system: Especially important for arc therapy.

    Science.gov (United States)

    Duggar, William Neil; Nguyen, Alex; Stanford, Jason; Morris, Bart; Yang, Claus C

    2016-01-01

    This study is to demonstrate the importance and a method of properly modeling the treatment couch for dose calculation in patient treatment using arc therapy. The 2 treatment couch tops-Aktina AK550 and Elekta iBEAM evo-of Elekta LINACs were scanned using Philips Brilliance Big Bore CT Simulator. Various parts of the couch tops were contoured, and their densities were measured and recorded on the Pinnacle treatment planning system (TPS) using the established computed tomography density table. These contours were saved as organ models to be placed beneath the patient during planning. Relative attenuation measurements were performed following procedures outlined by TG-176 as well as absolute dose comparison of static fields of 10 × 10 cm(2) that were delivered through the couch tops with that calculated in the TPS with the couch models. A total of 10 random arc therapy treatment plans (5 volumetric-modulated arc therapy [VMAT] and 5 stereotactic body radiation therapy [SBRT]), using 24 beams, were selected for this study. All selected plans were calculated with and without couch modeling. Each beam was evaluated using the Delta(4) dosimetry system (Delta(4)). The Student t-test was used to determine statistical significance. Independent reviews were exploited as per the Imaging and Radiation Oncology Core head and neck credentialing phantom. The selected plans were calculated on the actual patient anatomies with and without couch modeling to determine potential clinical effects. Large relative beam attenuations were noted dependent on which part of the couch top beams were passing through. Substantial improvements were also noted for static fields both calculated with the TPS and delivered physically when the couch models were included in the calculation. A statistically significant increase in agreement was noted for dose difference, distance to agreement, and γ-analysis with the Delta(4) on VMAT and SBRT plans. A credentialing review showed improvement in

  7. Comparative analysis of volumetric-modulated arc therapy and intensity-modulated radiotherapy for base of tongue cancer

    Directory of Open Access Journals (Sweden)

    L Nithya

    2014-01-01

    Full Text Available The aim of this study was to compare the various dosimetric parameters of dynamic multileaf collimator (MLC intensity modulated radiation therapy (IMRT plans with volumetric modulated arc therapy (VMAT plans for base of tongue cases. All plans were done in Monaco planning system for Elekta synergy linear accelerator with 80 MLC. IMRT plans were planned with nine stationary beams, and VMAT plans were done for 360° arc with single arc or dual arc. The dose to the planning target volumes (PTV for 70, 63, and 56 Gy was compared. The dose to 95, 98, and 50% volume of PTV were analyzed. The homogeneity index (HI and the conformity index (CI of the PTV 70 were also analyzed. IMRT and VMAT plan showed similar dose coverage, HI, and CI. Maximum dose and dose to 1-cc volume of spinal cord, planning risk volume (PRV cord, and brain stem were compared. IMRT plan and VMAT plan showed similar results except for the 1 cc of PRV cord that received slightly higher dose in VMAT plan. Mean dose and dose to 50% volume of right and left parotid glands were analyzed. VMAT plan gave better sparing of parotid glands than IMRT. In normal tissue dose analyses VMAT was better than IMRT. The number of monitor units (MU required for delivering the good quality of the plan and the time required to deliver the plan for IMRT and VMAT were compared. The number of MUs for VMAT was higher than that of IMRT plans. However, the delivery time was reduced by a factor of two for VMAT compared with IMRT. VMAT plans yielded good quality of the plan compared with IMRT, resulting in reduced treatment time and improved efficiency for base of tongue cases.

  8. Polymer matrices obtained by ionizing radiation for using in controlled drug delivery systems; Matrizes polimericas obtidas mediante radiacao ionizante para sua utilizacao como sistemas de liberacao controlada de farmacos

    Energy Technology Data Exchange (ETDEWEB)

    Martellini, Flavia

    1998-07-01

    Two kinds of controlled drug delivery system were obtained by gamma radiation induced polymerization. One of the system was obtained from an acrylic derivative of acetaminophen (40-hydroxyacetanilide), by copolymerization of 4-(acryloyloxy) acetanilide and N,N-dimethylacrylamide (DMAA) in dimethylformamide solution with 0,16 kGy/h dose rate and 54 Gy dose. The values of reactivity rate, r-D{sub MAA} = 0,31 {+-} 0,02 e r{sub AOA} -0,07 {+-} 0,12, were determined by Fineman-Ross method. The acetaminophen hydrolysis was carried out in alkaline and enzymatic (trypsin) media. Another kind of drug delivery system studied was solvent controlled type, being the drug immobilized in the hydrogel,. The hydrogels prepared by radiation polymerization of acryloyl-L-propine methylester (A-Pro-OMe) with 10 Gy dose, showed thermosensible property, swelling or shrinking in water with decreased or increased temperatures. The hydrogels were obtained with different crosslink density, trimethylolpropane trimethacrylate, and the monomers N, N-dimethyl acrylamide (DMAA) and 2-cyanoethyl acrylate to study the influence of the composition in the drug delivery rate. It was verified that the porous size besides being a characteristic of the matrix composition, it was also temperature dependent (thermosensible). The analgesic drug acetaminophen was immobilized by entrapment and by physical adsorption into the hydrogels matrices for 'in vitro' study. The insulin was immobilized by adsorption for 'in vivo' study. (author)

  9. Single Arc VMAT of H&N cancer

    DEFF Research Database (Denmark)

    Bertelsen, Anders

      Background: A few radiation treatment planning systems are currently able to plan volumetric modulated arc therapy (VMAT). The VMAT algorithm in Pinnacle3 TM is called SmartArc. The capability of SmartArc to generate complex treatment plans for the head and neck (H&N) region was tested.......   Materials and Methods:  This retrospective planning study includes patients with oropharyngeal or hypopharyngeal cancer previously treated with IMRT by utilization of the Pinnacle3TM treatment planning system and Elekta Synergy accelerators. Doses between 50Gy and 68Gy were prescribed to individual Planning...... reducing high dose volumes in normal tissues. The VMAT plans used fewer MUs compared to the IMRT plans and reduced the treatment time by approximately 40% compared to IMRT. Both IMRT and VMAT radiation treatment plans delivered on an Elekta Synergy accelerator produced clinically acceptable geometric dose...

  10. Hybrid laser-arc welding

    DEFF Research Database (Denmark)

    Hybrid laser-arc welding (HLAW) is a combination of laser welding with arc welding that overcomes many of the shortfalls of both processes. This important book gives a comprehensive account of hybrid laser-arc welding technology and applications. The first part of the book reviews...... the characteristics of the process, including the properties of joints produced by hybrid laser-arc welding and ways of assessing weld quality. Part II discusses applications of the process to such metals as magnesium alloys, aluminium and steel as well as the use of hybrid laser-arc welding in such sectors as ship...... building and the automotive industry. With its distinguished editor and international team of contributors, Hybrid laser-arc welding, will be a valuable source of reference for all those using this important welding technology. Professor Flemming Ove Olsen works in the Department of Manufacturing...

  11. SU-E-T-136: Dosimetric Robustness of a Magnetic Resonance Imaging Guided Radiation Therapy (MR-IGRT) System

    International Nuclear Information System (INIS)

    Purpose: To test the radiation delivery robustness of the first MR-IGRT system using a commercial cylindrical diode array detector (ArcCHECK) and an ionization thimble chamber (Exradin A18). Methods: The MR-IGRT system is composed of three evenly spaced Co-60 sources on a rotating gantry located between two magnet halves. The collimator for each source consists of 30 doubly-focused leaf pairs that allow the system to deliver both conformal and intensity modulated (IMRT) treatment plans. The system's delivery robustness was tested over a span of 6 months from September 2013 through February 2014. This was achieved by repeatedly delivering 10 patient plans. These plans consisted of 2 conformal prostates, 2 IMRT prostates, 2 IMRT head and neck, 2 IMRT breast, 1 IMRT pancreas, and 1 IMRT bladder. The plans were generated with the system's treatment planning software. Once the plans were generated, quality assurance plans were created on a digital ArcCHECK dataset. The ArcCHECK used for testing was specially designed to be MR-compatible by moving the power supply outside of the magnetic field. The A18 ionization chamber was placed in a custom plastic plug insert in the center of the ArcCHECK. Gamma analysis was used with the ArcCHECK for relative dose evaluating both 3%/3mm and 2%/2mm. Absolute point dose was compared between ion chamber measurement and treatment plan. Results: The ArcCHECK passing rate remained constant over the 6 month period. The average passing rate for 3%/3mm and 2%/2mm analysis was 98.6% ± 0.7 and 88.8% ± 2.9, respectively. The ion chamber measurements showed little variation with an average percent difference between planned dose verses measured dose of 0.9% ± 0.7. Conclusion: Minimal differences were noted in the delivery of the 10 patient plans. Over a period that included acceptance testing, commissioning, and clinical deliveries, the MR-IGRT system remained consistent in radiation delivery

  12. Capacitated arc routing problem and its extensions in waste collection

    Energy Technology Data Exchange (ETDEWEB)

    Fadzli, Mohammad; Najwa, Nurul [Institut Matematik Kejuruteraan, Universiti Malaysia Perlis, Kampus Pauh Putra, 02600 Arau, Perlis (Malaysia); Luis, Martino [Othman Yeop Abdullah Graduate School of Business, Universiti Utara Malaysia, 06010 Sintok, Kedah (Malaysia)

    2015-05-15

    Capacitated arc routing problem (CARP) is the youngest generation of graph theory that focuses on solving the edge/arc routing for optimality. Since many years, operational research devoted to CARP counterpart, known as vehicle routing problem (VRP), which does not fit to several real cases such like waste collection problem and road maintenance. In this paper, we highlighted several extensions of capacitated arc routing problem (CARP) that represents the real-life problem of vehicle operation in waste collection. By purpose, CARP is designed to find a set of routes for vehicles that satisfies all pre-setting constraints in such that all vehicles must start and end at a depot, service a set of demands on edges (or arcs) exactly once without exceeding the capacity, thus the total fleet cost is minimized. We also addressed the differentiation between CARP and VRP in waste collection. Several issues have been discussed including stochastic demands and time window problems in order to show the complexity and importance of CARP in the related industry. A mathematical model of CARP and its new version is presented by considering several factors such like delivery cost, lateness penalty and delivery time.

  13. Capacitated arc routing problem and its extensions in waste collection

    Science.gov (United States)

    Fadzli, Mohammad; Najwa, Nurul; Luis, Martino

    2015-05-01

    Capacitated arc routing problem (CARP) is the youngest generation of graph theory that focuses on solving the edge/arc routing for optimality. Since many years, operational research devoted to CARP counterpart, known as vehicle routing problem (VRP), which does not fit to several real cases such like waste collection problem and road maintenance. In this paper, we highlighted several extensions of capacitated arc routing problem (CARP) that represents the real-life problem of vehicle operation in waste collection. By purpose, CARP is designed to find a set of routes for vehicles that satisfies all pre-setting constraints in such that all vehicles must start and end at a depot, service a set of demands on edges (or arcs) exactly once without exceeding the capacity, thus the total fleet cost is minimized. We also addressed the differentiation between CARP and VRP in waste collection. Several issues have been discussed including stochastic demands and time window problems in order to show the complexity and importance of CARP in the related industry. A mathematical model of CARP and its new version is presented by considering several factors such like delivery cost, lateness penalty and delivery time.

  14. Heat Transfer Analysis for Industrial AC Electric Arc Furnace

    Institute of Scientific and Technical Information of China (English)

    (U)nal (C)amdali; Murat Tun(c)

    2005-01-01

    The heat transfer analysis was performed for an AC electric arc furnace (EAF). Heat losses by conduction, convection and radiation from outer surface, roof, bottom and electrodes of EAF were determined in detail. Some suggestions about decreasing heat losses were presented.

  15. Volumetric Modulated Arc Therapy vs. c-IMRT for the Treatment of Upper Thoracic Esophageal Cancer

    OpenAIRE

    Wu-Zhe Zhang; Tian-Tian Zhai; Jia-Yang Lu; Jian-Zhou Chen; Zhi-Jian Chen; De-Rui Li; Chuang-Zhen Chen

    2015-01-01

    Objective To compare plans using volumetric-modulated arc therapy (VMAT) with conventional sliding window intensity-modulated radiation therapy (c-IMRT) to treat upper thoracic esophageal cancer (EC). Methods CT datasets of 11 patients with upper thoracic EC were identified. Four plans were generated for each patient: c-IMRT with 5 fields (5F) and VMAT with a single arc (1A), two arcs (2A), or three arcs (3A). The prescribed doses were 64 Gy/32 F for the primary tumor (PTV64). The dose-volume...

  16. Volumetric modulated arc therapy for nasopharyngeal carcinoma: A dosimetric comparison with TomoTherapy and step-and-shoot IMRT

    International Nuclear Information System (INIS)

    Purpose: Volumetric modulated arc therapy (VMAT), a novel technique, employs a linear accelerator to conduct dynamic modulation rotation radiotherapy. The goal of this study was to compare VMAT with helical tomotherapy (HT) and step-and-shoot intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) patients with regard to the sparing effect on organs at risk (OARs), dosimetric quality, and efficiency of delivery. Materials and methods: Twenty patients with NPC treated by HT were re-planned by VMAT (two arcs) and IMRT (7–9 fields) for dosimetric comparison. The target area received three dose levels (70, 60, and 54 Gy) in 33 fractions using simultaneous integrated boosts technique. The Philips Pinnacle Planning System 9.0 was adopted to design VMAT, using SmartArc as the planning algorithm. For a fair comparison, the planning target volume (PTV) coverage of the 3 plans was normalized to the same level. Dosimetric comparisons between VMAT, HT, and IMRT plans were analyzed to evaluate (1) coverage, homogeneity, and conformity of PTV, (2) sparing of OARs, (3) delivery time, and (4) monitor units (MUs). Results: The VMAT, HT, and IMRT plans had similar PTV coverage with an average of 96%. There was no significant difference between VMAT and HT in homogeneity, while the homogeneity indices of VMAT (1.06) and HT (1.06) were better than IMRT plans (1.07, p < 0.05). HT plans provided a better conformity index (1.17) than VMAT (1.28, p = 0.01) and IMRT (1.36, p = 0.02). When compared with IMRT, VMAT and HT had a better sparing effect on brain stem and spinal cord (p < 0.05). The effect of parotid sparing was similar between VMAT (mean = 26.3 Gy) and HT (mean = 27.5 Gy), but better than IMRT (mean = 31.3 Gy, p < 0.01). The delivery time per fraction for VMAT (5.7 min) were much lower than for HT (9.5 min, p < 0.01) and IMRT (9.2 min, p < 0.01). Conclusions: Our results indicate that VMAT provides better sparing of normal tissue, homogeneity, and

  17. Fast approximate delivery of fluence maps: the VMAT case

    OpenAIRE

    Balvert, Marleen; Craft, David

    2016-01-01

    In this article we provide a method to generate the trade-off between delivery time and fluence map matching quality for volumetric modulated arc therapy (VMAT). At the heart of our method lies a mathematical programming model that, for a given duration of delivery, optimizes leaf trajectories and dose rates such that the desired fluence map is reproduced as well as possible. This model was presented for the single map case in a companion paper (Fast approximate delivery of fluence maps: the ...

  18. Of Eggs and Arcs

    Science.gov (United States)

    Burns, Joseph A.; Thomas, P. C.; Helfenstein, P.; Tiscareno, M. S.; Hedman, M. M.; Agarwal, M.

    2012-10-01

    New scenarios for the origins of Saturn’s rings/interior moons have directed scientific attention to the region just exterior to Saturn’s main rings. Four satellites (Aegaeon = Ae; Anthe = An; Methone = Me; Pallene = Pa) discovered by the Cassini mission on either side of Mimas’s orbit perhaps comprise a distinct class of ring-moon. They are tiny (R = 0.3-2.5 km); three (AeAnMe) are trapped in co-rotation resonances with Mimas and reside within ring-arcs; and at least two (MePa) have remarkably regular shapes. Images with pixel scales as fine as 27 m taken in May 2012 reveal Methone to be ovoid within 10 m (from sub-pixel limb detection) and devoid of any craters (>130 m) across its 9 km2 of surface; Pallene and even tiny Aegaeon have similar appearances in lesser-quality images. Numerical simulations demonstrate that particles comprising the surrounding ring-arcs populate the same resonances as their embedded moons; escape speeds from the moons are bodies. In this environment, the moons’ shapes are smooth equipotentials; electrostatic effects may also determine how grains settle to surfaces. Considering these shapes to represent equipotential surfaces for rotating, tidally distorted, homogeneous bodies, we infer mean satellite densities of 250+/-60 (Pa), 310+/-30 (Me), and 540+/-120 (Ae) kg m-3. About half of Methone’s leading hemisphere is covered by a sharply bounded, lemon-shaped, relatively dark region, having a form reminiscent of Mimas’s thermal anomaly (Howett et al. 2011). Its (601 nm) albedo is 13% lower than the bounding brighter material. An irregularly shaped, even-darker (by 4%) blotch straddles the apex of the moon’s motion. Impacts with circum-planetary meteoroids and plasma are likely responsible for these features.

  19. Use of volumetric-modulated arc therapy for treatment of Hodgkin lymphoma

    International Nuclear Information System (INIS)

    To evaluate volumetric-modulated arc therapy (VMAT) for treatment of Hodgkin lymphoma (HL) in patients where conventional radiotherapy was not deliverable. A planning computed tomography (CT) scan was acquired for a twelve-year-old boy with Stage IIIB nodular sclerosing HL postchemotherapy with positive positron emission tomography scan. VMAT was used for Phase 1 (19.8 Gy in 11 fractions) and Phase 2 (10.8 Gy in 6 fractions) treatment plans. Single anticlockwise arc plans were constructed using SmartArc (Philips Radiation Oncology Systems, Fitchburg, WI) with control points spaced at 4°. The inverse-planning objectives were to uniformly irradiate the planning target volume (PTV) with the prescription dose while keeping the volume of lung receiving greater than 20 Gy (V20Gy) to less than 30% and minimize the dose to the other adjacent organs at risk (OAR). Pretreatment verification was conducted and the treatment delivery was on an MLCi Synergy linear accelerator (Elekta Ltd, Crawley, UK). The planning results were retrospectively confirmed in a further 4 patients using a single PTV with a prescribed dose of 19.8 Gy in 11 fractions. Acceptable dose coverage and homogeneity were achieved for both Phase 1 and 2 plans while keeping the lung V20Gy at 22.5% for the composite plan. The beam-on times for Phase 1 and Phase 2 plans were 109 and 200 seconds, respectively, and the total monitor units were 337.2 MU and 292.5 MU, respectively. The percentage of measured dose points within 3% and 3 mm for Phase 1 and Phase 2 were 92% and 98%, respectively. Both plans were delivered successfully. The retrospective planning study showed that VMAT improved PTV dose uniformity and reduced the irradiated volume of heart and lung, although the volume of lung irradiated to low doses increased. Two-phased VMAT offers an attractive option for large volume sites, such as HL, giving a high level of target coverage and significant OAR sparing together with efficient delivery

  20. Use of volumetric-modulated arc therapy for treatment of Hodgkin lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young K., E-mail: Young.Lee@rmh.nhs.uk [Joint Department of Physics, Royal Marsden NHS Foundation Trust, Sutton, Surrey (United Kingdom); Bedford, James L. [Joint Department of Physics, Royal Marsden NHS Foundation Trust, Sutton, Surrey (United Kingdom); Taj, Mary [Paediatric Oncology, Royal Marsden NHS Foundation Trust, Sutton, Surrey (United Kingdom); Saran, Frank H. [Radiotherapy Department, Royal Marsden NHS Foundation Trust, Sutton, Surrey (United Kingdom)

    2013-01-01

    To evaluate volumetric-modulated arc therapy (VMAT) for treatment of Hodgkin lymphoma (HL) in patients where conventional radiotherapy was not deliverable. A planning computed tomography (CT) scan was acquired for a twelve-year-old boy with Stage IIIB nodular sclerosing HL postchemotherapy with positive positron emission tomography scan. VMAT was used for Phase 1 (19.8 Gy in 11 fractions) and Phase 2 (10.8 Gy in 6 fractions) treatment plans. Single anticlockwise arc plans were constructed using SmartArc (Philips Radiation Oncology Systems, Fitchburg, WI) with control points spaced at 4°. The inverse-planning objectives were to uniformly irradiate the planning target volume (PTV) with the prescription dose while keeping the volume of lung receiving greater than 20 Gy (V{sub 20} {sub Gy}) to less than 30% and minimize the dose to the other adjacent organs at risk (OAR). Pretreatment verification was conducted and the treatment delivery was on an MLCi Synergy linear accelerator (Elekta Ltd, Crawley, UK). The planning results were retrospectively confirmed in a further 4 patients using a single PTV with a prescribed dose of 19.8 Gy in 11 fractions. Acceptable dose coverage and homogeneity were achieved for both Phase 1 and 2 plans while keeping the lung V{sub 20} {sub Gy} at 22.5% for the composite plan. The beam-on times for Phase 1 and Phase 2 plans were 109 and 200 seconds, respectively, and the total monitor units were 337.2 MU and 292.5 MU, respectively. The percentage of measured dose points within 3% and 3 mm for Phase 1 and Phase 2 were 92% and 98%, respectively. Both plans were delivered successfully. The retrospective planning study showed that VMAT improved PTV dose uniformity and reduced the irradiated volume of heart and lung, although the volume of lung irradiated to low doses increased. Two-phased VMAT offers an attractive option for large volume sites, such as HL, giving a high level of target coverage and significant OAR sparing together with

  1. The dose delivery effect of the different Beam ON interval in FFF SBRT: TrueBEAM

    Science.gov (United States)

    Tawonwong, T.; Suriyapee, S.; Oonsiri, S.; Sanghangthum, T.; Oonsiri, P.

    2016-03-01

    The purpose of this study is to determine the dose delivery effect of the different Beam ON interval in Flattening Filter Free Stereotactic Body Radiation Therapy (FFF-SBRT). The three 10MV-FFF SBRT plans (2 half rotating Rapid Arc, 9 to10 Gray/Fraction) were selected and irradiated in three different intervals (100%, 50% and 25%) using the RPM gating system. The plan verification was performed by the ArcCHECK for gamma analysis and the ionization chamber for point dose measurement. The dose delivery time of each interval were observed. For gamma analysis (2%&2mm criteria), the average percent pass of all plans for 100%, 50% and 25% intervals were 86.1±3.3%, 86.0±3.0% and 86.1±3.3%, respectively. For point dose measurement, the average ratios of each interval to the treatment planning were 1.012±0.015, 1.011±0.014 and 1.011±0.013 for 100%, 50% and 25% interval, respectively. The average dose delivery time was increasing from 74.3±5.0 second for 100% interval to 154.3±12.6 and 347.9±20.3 second for 50% and 25% interval, respectively. The same quality of the dose delivery from different Beam ON intervals in FFF-SBRT by TrueBEAM was illustrated. While the 100% interval represents the breath-hold treatment technique, the differences for the free-breathing using RPM gating system can be treated confidently.

  2. Arc Interference Behavior during Twin Wire Gas Metal Arc Welding Process

    Directory of Open Access Journals (Sweden)

    Dingjian Ye

    2013-01-01

    Full Text Available In order to study arc interference behavior during twin wire gas metal arc welding process, the synchronous acquisition system has been established to acquire instantaneous information of arc profile including dynamic arc length variation as well as relative voltage and current signals. The results show that after trailing arc (T-arc is added to the middle arc (M-arc in a stable welding process, the current of M arc remains unchanged while the agitation increases; the voltage of M arc has an obvious increase; the shape of M arc changes, with increasing width, length, and area; the transfer frequency of M arc droplet increases and the droplet itself becomes smaller. The wire extension length of twin arc turns out to be shorter than that of single arc welding.

  3. Identification of GMAW dynamic process of arc welding robot based on radiation temperature measurement%基于辐射测温的弧焊机器人GMAW动态过程辨识

    Institute of Scientific and Technical Information of China (English)

    岳建锋; 李亮玉

    2007-01-01

    研究弧焊机器人GMAW(Gas Metal Arc Welding,熔化极气体弧焊)动态过程,采用比色测温仪对温度场特定点温度进行采集,采用面积法对送丝速度和测温点温度之间的模型进行了辨识.仿真结果表明,该模型准确地反映了输入输出的关系,仿真数据与实验数据的均方差仅为3%.

  4. On arc efficiency in gas tungsten arc welding

    Directory of Open Access Journals (Sweden)

    Nils Stenbacka

    2013-12-01

    Full Text Available The aim of this study was to review the literature on published arc efficiency values for GTAW and, if possible, propose a narrower band. Articles between the years 1955 - 2011 have been found. Published arc efficiency values for GTAW DCEN show to lie on a wide range, between 0.36 to 0.90. Only a few studies covered DCEP - direct current electrode positive and AC current. Specific information about the reproducibility in calorimetric studies as well as in modeling and simulation studies (considering that both random and systematic errors are small was scarce. An estimate of the average arc efficiency value for GTAW DCEN indicates that it should be about 0.77. It indicates anyway that the GTAW process with DCEN is an efficient welding method. The arc efficiency is reduced when the arc length is increased. On the other hand, there are conflicting results in the literature as to the influence of arc current and travel speed.

  5. Arc of opportunity.

    Science.gov (United States)

    Delaney, Adam Vai

    2011-07-01

    Born in Port Moresby, Papua New Guinea, the author had a 20 year career in diplomacy, political affairs, and development policy analysis at the Pacific Islands Forum, the United Nations in New York; the Prime Minister's Department in Papua New Guinea (PNG) and in the Foreign Ministry of PNG. He has also been involved in theatre for over a decade in PNG, and participated in a three-month program at the Eugene O'Neill Theatre Center in Connecticut, USA. He is currently the Business Development Manager at the Torres Strait Regional Authority (Commonwealth) on Thursday Island. Since 1975 the Australian government's overseas development policy has supported various sectoral programs in its neighbouring countries, in particular Papua New Guinea and the Solomon Islands. The "creative" field has not been prominent in this strategy. While natural resources and the sports sectors have gained much greater attention, in terms of being viable international commercial enterprises, the arts, have remained stagnant. In this paper the need for joint programs genuinely supporting "wellbeing" and promoting social enterprise throughout the "arc of opportunity" is described to harness Melanesian creativity to compete successfully in world-markets, starting with penetration of the largest economy at its door-step: Australia.

  6. Investigation on the arc light spectrum in GTA welding

    Directory of Open Access Journals (Sweden)

    M.S. Węglowski

    2007-01-01

    Full Text Available Purpose: In the paper there are presented results of the influence of welding parameters on spectral intensity ofthe welding arc in the range of 340÷860 nm. The main goal was checking whether the visible radiation of thearc provides information which might prove to be useful in monitoring of the welding process, similarly as thesignals recorded in the electric circuit of the welding arc.Design/methodology/approach: The experimental station was designed and build. A spectrophotometer, in thevisible spectral range of 340 nm to 860 nm, was used. The investigations were conducted on the automated GTAwelding station. For each welding parameter the arc light spectrum was measuredFindings: Research results presented in this paper indicate that the welding arc radiation contains a number ofinformation concerning the course of the welding process. That signal is much more sensitive to the changes ofwelding conditions and should be used as a tool for monitoring of the TIG welding processResearch limitations/implications: The fiber spectrophotometer in the visible spectral range of 340 nm to860 nm is an expensive instrument and that fore it can be used only as a complementary tool in monitoring ofwelding processes.Practical implications: The gained experience allows directing farther research on the welding arc radiationphenomenon and the possibilities of using this signal for on-line monitoring of the welding process onautomated and robotized stands.This sensing system will be particularly attractive for welded structures manufacturing industry because it couldsignificantly reduce the cost for post weld analysis and repairsOriginality/value: Three fitting functions: Lorentz, Gauss and Voight were investigated as a means to simulatethe spectrum distribution. The mathematical-physical model of the arc light emission and neural networkswere compared

  7. STUDY ON THE PRESSURE IN PLASMA ARC

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The axial pressure in plasma arc is measured under different conditions. The effects of the parameters, such as welding current, plasma gas flow rate, electrode setback and arc length, on the pressure in plasma arc are investigated and quantitative analyzed to explain the relationship between the quality of weld and the matching of parameters in plasma arc welding process.

  8. [Arc spectrum diagnostic and heat coupling mechanism analysis of double wire pulsed MIG welding].

    Science.gov (United States)

    Liu, Yong-qiang; Li, Huan; Yang, Li-jun; Zheng, Kai; Gao, Ying

    2015-01-01

    A double wire pulsed MIG welding test system was built in the present paper, in order to analyze the heat-coupling mechanism of double wire pulsed MIG welding, and study are temperature field. Spectroscopic technique was used in diagnostic analysis of the are, plasma radiation was collected by using hollow probe method to obtain the arc plasma optical signal The electron temperature of double wire pulsed MIG welding arc plasma was calculated by using Boltzmann diagram method, the electron temperature distribution was obtained, a comprehensive analysis of the arc was conducted combined with the high speed camera technology and acquisition means of electricity signal. The innovation of this paper is the combination of high-speed camera image information of are and optical signal of arc plasma to analyze the coupling mechanism for dual arc, and a more intuitive analysis for are temperature field was conducted. The test results showed that a push-pull output was achieved and droplet transfer mode was a drop in a pulse in the welding process; Two arcs attracted each other under the action of a magnetic field, and shifted to the center of the arc in welding process, so a new heat center was formed at the geometric center of the double arc, and flowing up phenomenon occurred on the arc; Dual arc electronic temperature showed an inverted V-shaped distribution overall, and at the geometric center of the double arc, the arc electron temperature at 3 mm off the workpiece surface was the highest, which was 16,887.66 K, about 4,900 K higher than the lowest temperature 11,963.63 K.

  9. Helical tomotherapy quality assurance with ArcCHECK

    International Nuclear Information System (INIS)

    To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an A1SL ion chamber inserted in the central holder. The ArcCHECK was positioned 10 cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquid and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by ∼2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient

  10. Computational Analysis of Shock Layer Emission Measurements in an Arc-Jet Facility

    Science.gov (United States)

    Gokcen, Tahir; Park, Chung S.; Newfield, Mark E.; Fletcher, Douglas G.

    1998-01-01

    This paper reports computational analysis of radiation emission experiments in a high enthalpy arc-jet wind tunnel at NASA Ames Research Center. Recently, as part of ongoing arc-jet characterization work, spectroscopic radiation emission experiments have been conducted at the 20 MW NASA Ames arc-jet facility. The emission measurements were obtained from the arc-jet freestream and from a shock layer formed in front of flatfaced models. Analysis of these data is expected to provide valuable information about the thermodynamic state of the gas in the arc-jet freestream and in the shock layer as well as thermochemical equilibration processes behind the shock in arc-jet flows. Knowledge of the thermodynamic state of the gas in arc-jet test flows and especially within the shock layer is essential to interpret the heat transfer measurements such as in surface catalysis experiments. The present work is a continuation of previous work and focuses on analysis of the emission data obtained at relatively low-pressure conditions for which the arc-jet shock layer is expected to be in thermal and chemical nonequilibrium. Building blocks of the present computational analysis are: (1) simulation of nonequilibrium expanding flow in the converging-diverging conical nozzle and supersonic jet; (2) simulation of nonequilibrium shock layer formed in front of the flat-faced cylinder model; and (3) prediction of line-of-sight radiation from the computed flowfield. For computations of the nonequilibrium flow in the conical nozzle and shock layer, multi-temperature nonequilibrium codes with the axisymmetric formulation are used. For computations of line-of-sight radiation. a nonequilibrium radiation code (NEQAIR) is used to predict emission spectra from the computed flowfield. Computed line-of-sight averaged flow properties such as vibrational and rotational temperatures, species number densities within the shock layer will be compared with those deduced from the experimental spectra

  11. TRANSDERMAL DRUG DELIVERY: A TECHNICAL WRITEUP

    Directory of Open Access Journals (Sweden)

    Vandana Yadav

    2012-02-01

    Full Text Available Transdermal drug delivery is another system which provides controlled and continuous delivery of the drug through the skin into the systemic circulation. Topical application which involves drug transport to viable epidermal and/or dermal tissues of the skin for local therapeutic effect while a very major fraction of drug is transported into the systemic blood circulation. Transdermal route provides many advantages over conventional oral and invasive methods of drug delivery such as avoids first pass metabolism, improve patient compliance, maintance steady state plasma concentration. This article provides an overview of skin permeation pathways, types of transdermal drug delivery system, methods of preparation with different methods of evaluation, and the recent advancement in transdermal drug delivery, which includes Transfersomes, Magnetophoresis, Controlled Heat Aided Drug Delivery System, Laser Radiation, Medicated Tattoos, Laser radiation.

  12. The Time-Dependent Multiple-Vehicle Prize-Collecting Arc Routing Problem

    DEFF Research Database (Denmark)

    Black, Daniel; Eglese, Richard; Wøhlk, Sanne

    2015-01-01

    In this paper, we introduce a multi vehicle version of the Time-Dependent Prize-Collecting Arc Routing Problem (TD-MPARP). It is inspired by a situation where a transport manager has to choose between a number of full truck load pick-ups and deliveries to be performed by a fleet of vehicles. Real...

  13. Stereotactic body radiation therapy for liver metastasis-Case report and review of the literature. The role of patient preparation, treatment planning and its delivery

    Directory of Open Access Journals (Sweden)

    Marta Adamczyk

    2014-01-01

    Results: The conventional 3-dimensional conformal plan, which fulfilled all dose constraints for target and organs at risk, was accepted for the treatment. Almost for all performed patient position verifications, on-line evaluated results were kept under 5 mm. Conclusions: The analysis presents the possible way of treating patients with liver metastasis. The SBRT treatment prepared and verified according our protocol can be implemented in clinical practice for a vast majority of such patients. The literature validation of our liver SBRT protocol showed that it has the potential for ensuring the effective and patient-friendly delivery.

  14. Drug delivery system prepared by ionizing radiation of the N,N-dimethyl acrylamide with acryloyloxy-acetanilide copolymerization; Sistema de liberacao de droga obtido via radiacao ionizante pela copolimerizacao do N,N-dimetilacrilamida com 4-acriloiloxiacetanilida

    Energy Technology Data Exchange (ETDEWEB)

    Martellini, Flavia; Higa, Olga Z. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Queiroz, Alvaro A.A. de [Escola Federal de Engenharia de Itajuba, MG (Brazil); Rodighiero, Paolo [Universidade de Padova (Italy). Inst. de Ciencias Farmaceuticas

    1995-12-31

    Radiation induced polymerization has been used in biomaterials used in systems which such as drug delivery (DDS). This work describes the copolymerization of the monomers by gamma rays N,N-dimethyl acrylamide (DMAA) and acryloyloxy-acetanilide (AOA) for the immobilization of paracetamol, an analgesic and anti thermic drug. Dimethylformamide solutions were used in two concentrations of DMAA and AOA (F{sub DMAA/AOA} = 0,85/015 and 0,70/0,30, where F = molar fraction in the monomer feed). The samples were irradiated in the dose range of 30-800 Gy. The copolymer poly(DMAA-co-AOA) characterization was carried out by FTIR and {sup 1}HRMN. The hydrolysis was studied considering the formation of sodium salts of 4-hydroxy acetanilide at different times of treatment using colorimetric assay. (author). 6 refs., 5 figs.

  15. Arc modelling in SF6 circuit breakers

    International Nuclear Information System (INIS)

    The paper presents the work done by an operator, EDF and two manufacturers to improve the physical models and numerical methods used to simulate the behavior of the plasma and cold gas around it in a breaking chamber of the HV SF6 circuit breaker, during the high-current phase. This work concerns flow phenomena, in particular incorporating compressibility and the study of turbulence, the coupling between these flow phenomena and electromagnetic phenomena, and finally, radiation - which plays an essential role in energy transfer during the high-current phase. For this latter aspect, emission but also absorption were proven to play a major role, and the two were introduced into the models. The paper presents the models developed and the results obtained with them for simulation of two circuit breaker mock-ups (a double-pressure circuit breaker mock-up and a self-expanding and rotating arc circuit breaker mock-up). (author)

  16. Laser guided and stabilized gas metal arc welding processes (LGS-GMA)

    Science.gov (United States)

    Hermsdorf, Jörg; Barroi, Alexander; Kaierle, Stefan; Overmeyer, Ludger

    2013-05-01

    The demands of the industry are cheap and fast production of highly sophisticated parts without compromises in product quality. To realize this requirement, we have developed a laser guided and stabilized gas metal arc process (LGS-GMA welding). The new welding process is based on a gas metal arc process using low power laser radiation for stabilization. The laser stabilization of gas metal arcs welding is applied to joint welding and cladding. With only 400 W laser power and a focal spot of 1.6 mm the laser radiation is mainly interacting with the arc plasma in order to guide and stabilize it. In joint welding up to 100% increase in welding speed is possible, at equal penetration depth. The guidance effect also enables the process to weld in challenging situations like different sheet thicknesses. Used for cladding, the enhanced process stability allows low penetration depth with dilutions of only 3%. Coatings with up to 63 HRC were achieved.

  17. High pressure neon arc lamp

    Science.gov (United States)

    Sze, Robert C.; Bigio, Irving J.

    2003-07-15

    A high pressure neon arc lamp and method of using the same for photodynamic therapies is provided. The high pressure neon arc lamp includes a housing that encloses a quantity of neon gas pressurized to about 500 Torr to about 22,000 Torr. At each end of the housing the lamp is connected by electrodes and wires to a pulse generator. The pulse generator generates an initial pulse voltage to breakdown the impedance of the neon gas. Then the pulse generator delivers a current through the neon gas to create an electrical arc that emits light having wavelengths from about 620 nanometers to about 645 nanometers. A method for activating a photosensitizer is provided. Initially, a photosensitizer is administered to a patient and allowed time to be absorbed into target cells. Then the high pressure neon arc lamp is used to illuminate the target cells with red light having wavelengths from about 620 nanometers to about 645 nanometers. The red light activates the photosensitizers to start a chain reaction that may involve oxygen free radicals to destroy the target cells. In this manner, a high pressure neon arc lamp that is inexpensive and efficiently generates red light useful in photodynamic therapy is provided.

  18. The Banda Arc subduction enigma

    Science.gov (United States)

    Spakman, Wim; Hall, Robert

    2010-05-01

    The spectacularly curved Banda arc comprises young oceanic crust enclosed by a volcanic inner arc, outer arc islands, and a trough parallel to the Australian continental margin. Seismicity defines a spoon-shaped lithospheric fold in the upper mantle for which there are two contrasting explanations: deformation of a single subducted slab, or two different slabs subducted from north and south. We show that the Banda arc resulted from subduction of a single slab. Based on geology and seismic tomography, we argue that the arc formed since 15 Ma by subduction of a Jurassic oceanic embayment within the Australian plate. Viewed in an Atlantic-Indian hotspot reference frame, the stationary E-W striking Java trench propagated ESE into the Banda embayment by hinge rollback. Extension of the upper plate formed oceanic crust in the present Banda Sea between stretched continental crust of Australian origin. Slab morphology depends primarily on the geometry of the continental margin enclosing the embayment. Our model explains the first order tectonic development of the Banda region and links slab deformation to absolute plate motion.

  19. The ARC-EN-CIEL FEL Proposal

    CERN Document Server

    Couprie, M E

    2005-01-01

    ARC-EN-CIEL (Accelerator-Radiation for Enhanced Coherent Intense Extended Light), the French project of a fourth generation light source aims at providing the user community with coherent femtosecond light pulses covering from UV to soft X ray. It is based on a CW 1 GeV superconducting linear accelerator delivering high charge, subpicosecond, low emittance electron bunches with a high repetition rate. The FEL is based on in the injection of High Harmonics in Gases in a High Gain Harmonic Generation scheme, leading to a rather compact solution. The produced radiation extending down to 0.8 nm with the Non Linear Harmonic reproduces the good longitudinal and transverse coherence of the harmonics in gas. Optional beam loops are foreseen to increase the beam current or the energy. They will accommodate fs synchrotron radiation sources in the IR, VUV and X ray ranges and a FEL oscillator in the 10 nm range. An important synergy is expected between accelerator and laser communities. Indeed, electron plasma accelerat...

  20. Is high–dose rate RapidArc-based radiosurgery dosimetrically advantageous for the treatment of intracranial tumors?

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Bo; Yang, Yong, E-mail: yangy2@upmc.edu; Li, Xiang; Li, Tianfang; Heron, Dwight E.; Saiful Huq, M.

    2015-04-01

    In linac-based stereotactic radiosurgery (SRS) and radiotherapy (SRT), circular cone(s) or conformal arc(s) are conventionally used to treat intracranial lesions. However, when the target is in close proximity to critical structures, it is frequently quite challenging to generate a quality plan using these techniques. In this study, we investigated the dosimetric characteristics of using high–dose rate RapidArc (RA) technique for radiosurgical treatment of intracranial lesions. A total of 10 intracranial SRS/SRT cases previously planned using dynamic conformal arc (DCA) or cone-based techniques have been included in this study. For each case, 3 treatment plans were generated: (1) a DCA plan with multiple noncoplanar arcs, (2) a high–dose rate RA plan with arcs oriented the same as DCA (multiple-arc RA), and 3) a high–dose rate RA plan with a single coplanar arc (single-arc RA). All treatment plans were generated under the same prescription and similar critical structure dose limits. Plan quality for different plans was evaluated by comparing various dosimetric parameters such as target coverage, conformity index (CI), homogeneity index (HI), critical structures, and normal brain tissue doses as well as beam delivery time. With similar critical structure sparing, high–dose rate RA plans can achieve much better target coverage, dose conformity, and dose homogeneity than the DCA plans can. Plan quality indices CI and HI, for the DCA, multiple-arc RA, and single-arc RA techniques, were measured as 1.67 ± 0.39, 1.32 ± 0.28, and 1.38 ± 0.30 and 1.24 ± 0.11, 1.10 ± 0.04, and 1.12 ± 0.07, respectively. Normal brain tissue dose (V{sub 12} {sub Gy}) was found to be similar for DCA and multiple-arc RA plans but much larger for the single-arc RA plans. Beam delivery was similar for DCA and multiple-arc RA plans but shorter with single-arc RA plans. Multiple-arc RA SRS/SRT can provide better treatment plans than conventional DCA plans, especially for complex cases.

  1. Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy

    DEFF Research Database (Denmark)

    Pommer, T.; Falk, Marianne; Poulsen, Per Rugaard;

    2013-01-01

    This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the ta...

  2. Analysis of Fault Arc in High-Speed Switch Applied in Hybrid Circuit Breaker

    Science.gov (United States)

    Wu, Yifei; Ren, Zhigang; Feng, Ying; Li, Mei; Zhang, Hantian

    2016-03-01

    The behavior of fault arc in a high-speed switch (HSS) has been studied theoretically and experimentally. A simplified HSS setup is designed to support this work. A two-dimensional arc model is developed to analyze the characteristics of fault arc based on magnetic-hydrodynamic (MHD) theory. The advantage of such a model is that the thermal transfer coefficient can be determined by depending on the numerical method alone. The influence of net emission coefficients (NEC) radiation model and P1 model on fault arc is analyzed in detail. Results show that NEC model predicts more radiation energy and less pressure rise without the re-absorption effect considered. As a consequence, P1 model is more suitable to calculate the pressure rise caused by fault arc. Finally, the pressure rise during longer arcing time for different arc currents is predicted. supported by National Key Basic Research Program of China (973 Program) (No. 2015CB251001), National Natural Science Foundation of China (Nos. 51221005, 51177124, 51377128, 51323012), the Science and Technology Project Funds of the Grid State Corporation SGSNKYOOKJJS1501564 and Shaanxi Province Natural Science Foundation of China (No. 2013JM-7010)

  3. Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

    Institute of Scientific and Technical Information of China (English)

    Suresh Rana; ChihYao Cheng

    2013-01-01

    The volumetric modulated arc therapy (VMAT) technique, in the form of RapidArc, is widely used to treat prostate cancer. The full-single arc (f-SA) technique in RapidArc planning for prostate cancer treatment provides efficient treatment, but it also delivers a higher radiation dose to the rectum. This study aimed to compare the dosimetric results from the new partial-single arc (p-SA) technique with those from the f-SA technique in RapidArc planning for prostate cancer treatment. In this study, 10 patients with low-risk prostate cancer were selected. For each patient, two sets of RapidArc plans (f-SA and p-SA) were created in the Eclipse treatment planning system. The f-SA plan was created using one ful arc, and the p-SA plan was created using planning parameters identical to those of the f-SA plan but with anterior and posterior avoidance sectors. Various dosimetric parameters of the f-SA and p-SA plans were evaluated and compared for the same target coverage and identical plan optimization parameters. The f-SA and p-SA plans showed an average difference of ±1% for the doses to the planning target volume (PTV), and there were no clear differences in dose homogeneity or plan conformity. In comparison to the f-SA technique, the p-SA technique reduced the doses to the rectum by approximately 6.1% to 21.2%, to the bladder by approximately 10.3%to 29.5%, and to the penile bulb by approximately 2.2%. In contrast, the dose to the femoral heads, the integral dose, and the number of monitor units were higher in the p-SA plans by approximately 34.4%, 7.7%, and 9.2%, respectively. In conclusion, it is feasible to use the p-SA technique for RapidArc planning for prostate cancer treatment. For the same PTV coverage and identical plan optimization parameters, the p-SA technique is better in sparing the rectum and bladder without compromising plan conformity or target homogeneity when compared to the f-SA technique.

  4. Modelling of gas-metal arc welding taking into account metal vapour

    Energy Technology Data Exchange (ETDEWEB)

    Schnick, M; Fuessel, U; Hertel, M; Haessler, M [Institute of Surface and Manufacturing Technology, Technische Universitaet Dresden, D-01062 Dresden (Germany); Spille-Kohoff, A [CFX Berlin Software GmbH, Karl-Marx-Allee 90, 10243 Berlin (Germany); Murphy, A B [CSIRO Materials Science and Engineering, PO Box 218, Lindfield NSW 2070 (Australia)

    2010-11-03

    The most advanced numerical models of gas-metal arc welding (GMAW) neglect vaporization of metal, and assume an argon atmosphere for the arc region, as is also common practice for models of gas-tungsten arc welding (GTAW). These models predict temperatures above 20 000 K and a temperature distribution similar to GTAW arcs. However, spectroscopic temperature measurements in GMAW arcs demonstrate much lower arc temperatures. In contrast to measurements of GTAW arcs, they have shown the presence of a central local minimum of the radial temperature distribution. This paper presents a GMAW model that takes into account metal vapour and that is able to predict the local central minimum in the radial distributions of temperature and electric current density. The influence of different values for the net radiative emission coefficient of iron vapour, which vary by up to a factor of hundred, is examined. It is shown that these net emission coefficients cause differences in the magnitudes, but not in the overall trends, of the radial distribution of temperature and current density. Further, the influence of the metal vaporization rate is investigated. We present evidence that, for higher vaporization rates, the central flow velocity inside the arc is decreased and can even change direction so that it is directed from the workpiece towards the wire, although the outer plasma flow is still directed towards the workpiece. In support of this thesis, we have attempted to reproduce the measurements of Zielinska et al for spray-transfer mode GMAW numerically, and have obtained reasonable agreement.

  5. Minor arcs for Goldbach's problem

    OpenAIRE

    Helfgott, H. A.

    2012-01-01

    The ternary Goldbach conjecture states that every odd number n>=7 is the sum of three primes. The estimation of sums of the form \\sum_{p\\leq x} e(\\alpha p), \\alpha = a/q + O(1/q^2), has been a central part of the main approach to the conjecture since (Vinogradov, 1937). Previous work required q or x to be too large to make a proof of the conjecture for all n feasible. The present paper gives new bounds on minor arcs and the tails of major arcs. This is part of the author's proof of the ternar...

  6. Unzipping of the volcano arc, Japan

    Science.gov (United States)

    Stern, R.J.; Smoot, N.C.; Rubin, M.

    1984-01-01

    A working hypothesis for the recent evolution of the southern Volcano Arc, Japan, is presented which calls upon a northward-progressing sundering of the arc in response to a northward-propagating back-arc basin extensional regime. This model appears to explain several localized and recent changes in the tectonic and magrnatic evolution of the Volcano Arc. Most important among these changes is the unusual composition of Iwo Jima volcanic rocks. This contrasts with normal arc tholeiites typical of the rest of the Izu-Volcano-Mariana and other primitive arcs in having alkaline tendencies, high concentrations of light REE and other incompatible elements, and relatively high silica contents. In spite of such fractionated characteristics, these lavas appear to be very early manifestations of a new volcanic and tectonic cycle in the southern Volcano Arc. These alkaline characteristics and indications of strong regional uplift are consistent with the recent development of an early stage of inter-arc basin rifting in the southern Volcano Arc. New bathymetric data are presented in support of this model which indicate: 1. (1) structural elements of the Mariana Trough extend north to the southern Volcano Arc. 2. (2) both the Mariana Trough and frontal arc shoal rapidly northwards as the Volcano Arc is approached. 3. (3) rugged bathymetry associated with the rifted Mariana Trough is replaced just south of Iwo Jima by the development of a huge dome (50-75 km diameter) centered around Iwo Jima. Such uplifted domes are the immediate precursors of rifts in other environments, and it appears that a similar situation may now exist in the southern Volcano Arc. The present distribution of unrifted Volcano Arc to the north and rifted Mariana Arc to the south is interpreted not as a stable tectonic configuration but as representing a tectonic "snapshot" of an arc in the process of being rifted to form a back-arc basin. ?? 1984.

  7. Peritoneal macrophages mediated delivery of chitosan/siRNA nanoparticle to the lesion site in a murine radiation-induced fibrosis model

    DEFF Research Database (Denmark)

    Nawroth, Isabel; Alsner, Jan; Deleuran, B.W.;

    2013-01-01

    Background. Radiation-induced fibrosis (RIF) is a dose-limiting complication of cancer radiotherapy and causes serious problems, i.e. restricted tissue flexibility, pain, ulceration or necrosis. Recently, we have successfully treated RIF in a mouse model by intraperitoneal administration of chito......Background. Radiation-induced fibrosis (RIF) is a dose-limiting complication of cancer radiotherapy and causes serious problems, i.e. restricted tissue flexibility, pain, ulceration or necrosis. Recently, we have successfully treated RIF in a mouse model by intraperitoneal administration...... of chitosan/siRNA nanoparticles directed towards silencing TNF alpha in local macrophage populations, but the mechanism for the therapeutic effect at the lesion site remains unclear. Methods. Using the same murine RIF model we utilized an optical imaging technique and fluorescence microscopy to investigate...

  8. Dosimetric comparison between volumetric modulated arc therapy and fixed-gantry dynamic intensity modulated radiation therapy for rectal cancer radiotherapy%直肠癌旋转容积调强与固定野动态调强的剂量学比较

    Institute of Scientific and Technical Information of China (English)

    花威; 李军; 谭飞; 陈婷婷; 汪步海

    2012-01-01

    目的:比较旋转容积调强(VMAT)与固定野动态调强(dIMRT)在直肠癌放疗计划中的剂量学差异.方法:8例直肠癌患者利用瓦里安计划系统(Eclipse 8.6)分别进行VMAT和dIMRT放射治疗计划设计.利用剂量体积直方图来比较两种计划中靶区和危及器官的剂量学差异.结果:与dIMRT相比,VMAT靶区适合度指数(CI)、靶区剂量均匀性指数(HI)均更接近1,Dmin为(43.403±0.486)Gy,更接近处方剂量,差异有统计学意义,P<0.05.在VMAT计划中小肠的D30%、D50%和Dmean分别为(25.918±1.216)、(22.340士3.784)和(23.547±2.863) Gy,低于dIMRT计划的(28.073±3.114)、(24.172±2.540)和(25.257±1.374) Gy,P值分别为0.00、0.01和0.00;膀胱的D30%为(35.380±2.734) Gy,较dIMRT的(30.123±2.209) Gy偏高,P=0.00,但仍远低于剂量限值;股骨头的D5%和Dmean分别为(31.344±3.556)和(20.179±3.017) Gy,显著高于dIMRT计划的(26.731±2.828)和(17.459±3.279) Gy,P值均为0.00.VMAT总MU减少52.7%,治疗时间仅为dIMRT的1/4.结论:VMAT计划可以达到或优于dIMRT计划的靶区剂量分布,能更好地降低部分危及器官的受照剂量,并且具有较少总MU、总治疗时间的优势,减少了治疗中不确定性因素的影响及患者不适感.%OBJECTIVE: To compare the dosimetric difference between volumetric modulated arc therapy(VMAT) and fixed-gantry dynamic intensity modulated radiation therapy(dIMRT) for rectal cancer. METHODS: VMAT and dlM-RT treatment plans of 8 rectal cancer cases were generated by Vrian Eclipse ver8. 6 treatment planning systerm. Dose volume histograms were used to compare the target volume and organs at risks. RESULTS: Compared to dIMRT,conformity index(CI) and homogeneity index(HI) of VMAT closer to one. Dmin of VMAT was (43. 403 ± 0. 486) Gy,closer to prescription dose. There were significant differences in CI,HI and Dmin(P<0. 05). The small intestinal's D30% ,D50% and Dmean were larger in dIMRT than those in VAMT(P values were

  9. Dosimetric comparison of different multileaf collimators in volumetric modulated arc therapy for malignant pleural mesothelioma

    Institute of Scientific and Technical Information of China (English)

    Fuli Zhang; Jun Hou; Jianping Chen; Huayong Jiang; Weidong Xu; Yadi Wang; Junmao Gao; Qingzhi Liu; Na Lu; Diandian Chen; Bo Yao

    2015-01-01

    Objective The aiom of the study was to compare the impacts of two types of multileaf col imators (MLC) [standard MLC with a width of 10 mm (sMLC) and micro-MLC with a width of 5 mm (mMLC)] on volumetric modulated arc therapy (VMAT) planning for malignant pleural mesothelioma. Methods VMAT for ten patients with inoperable malignant pleural mesotheliomas was retrospectively planned with the sMLC and mMLC. Histogram-based dose-volume parameters of the planning target vol-ume (PTV) [conformity index (CI) and homogeneous index (HI)] and organs-at-risk were compared for VMAT plans with sMLC (sMLC-VMAT) and mMLC (mMLC-VMAT). Results The mMLC-VMAT plans were more ef icient (average delivery time: 2.67±1.49 min) than the sMLC-VMAT plans (average delivery time: 4.21 ± 2.03 min; P 0.05). In addition, significant dose sparing in the fraction of the ipsilateral lung volume receiving > 20 Gy (V20; 54.72 ± 27.08 vs 58.52 ± 29.30) and > 30 Gy (V30; 42.74 ± 27.86 vs 46.86 ± 31.49) radiation, respectively, was observed for the mMLC plans (P < 0.05). Conclusion Comparing sMLC-VMAT and mMLC-VMAT not only demonstrated the higher ef iciency and better optimal target coverage of mMLC-VMAT, but also considerably improved the dose sparing of the ipsilateral lung in the VMAT plans for malignant pleural mesothelioma.

  10. Hooded arc ion-source

    CERN Multimedia

    1972-01-01

    The positioning system for the hooded arc ion-source, shown prior to mounting, consists of four excentric shafts to locate the ion-source and central electrodes. It will be placed on the axis of the SC and introduced into the vacuum tank via the air locks visible in the foreground.

  11. Craniospinal irradiation using Rapid Arc

    Energy Technology Data Exchange (ETDEWEB)

    Fandino, J. M.; Silva, M. C.; Marino, A.; Candal, A.; Diaz, I.; Fernandez, C.; Gesto, C.; Izquierdo, P.; Losada, C.; Poncet, M.; Soto, M.; Triana, G.

    2013-07-01

    Cranio-Spinal Irradiation is technically very challenging, historically field edge matching is needed because of the mechanical limitations of standard linear accelerators. The purpose of this study is to assess the Volumetric Arc Therapy as a competitive technique for Cranio-Spinal Irradiation compared to the conventional 3D Conformal Radiotherapy technique. (Author)

  12. STRUVE arc and EUPOS® stations

    Science.gov (United States)

    Lasmane, Ieva; Kaminskis, Janis; Balodis, Janis; Haritonova, Diana

    2013-04-01

    The Struve Geodetic Arc was developed in Years 1816 to 1855, 200 years ago. Historic information on the points of the Struve Geodetic Arc are included in the UNESCO World Heritage list in 2005. Nevertheless, the sites of many points are still not identified nor included in the data bases nowadays. Originally STRUVE arc consisted of 258 main triangles with 265 triangulation points. Currently 34 of the original station points are identified and included in the in the UNESCO World Heritage list. identified original measurement points of the Meridian Arc are located in Sweden (7 points), Norway (15), Finland (83), Russia (1), Estonia (22), Latvia (16), Lithuania (18), Belorussia (28), Ukraine (59) and Moldova (27). In Year 2002 was initiated another large coverage project - European Position Determination System "EUPOS®". Currently there are about 400 continuously operating GNSS (Global Navigation Satellite Systems) stations covering EU countries Estonia, Latvia, Lithuania, Poland, Czech Republic, Slovakia, Hungary, Bulgaria, Romania and East European countries Ukraine and Moldavia. EUPOS® network is a ground based GNSS augmentation system widely used for geodesy, land surveying, geophysics and navigation. It gives the opportunity for fast and accurate position determination never available before. It is an honorable task to use the EUPOS® system for research of the Struve triangulation former sites. Projects with Struve arc can popularize geodesy, geo-information and its meaning in nowadays GIS and GNSS systems. Struve Arc and its points is unique cooperation cross-border object which deserve special attention because of their natural beauty and historical value for mankind. GNSS in geodesy discovers a powerful tool for the verification and validation of the height values of geodetic leveling benchmarks established historically almost 200 years ago. The differential GNSS and RTK methods appear very useful to identify vertical displacement of landscape by means of

  13. Dust in the arcs of Methone and Anthe

    CERN Document Server

    Sun, Kai-Lung; Spahn, Frank

    2015-01-01

    Methone and Anthe are two tiny moons (with diameter $<3$ km) in the inner part of Saturn's E ring. Both moons are embedded in an arc of dust particles. To understand the amount of micron-sized dust and their spatial distribution in these arcs, we model the source, dynamical evolution, and sinks of these dust in the arc. We assume hypervelocity impacts of micrometeoroids on the moons as source of these dust (Hedman et al., 2009), the so called impact-ejecta process (Krivov et al., 2003; Spahn et al., 2006). After ejecting and escaping from the moons, these micron-sized particles are subject to several perturbing forces, including gravitational perturbation from Mimas, oblateness of Saturn, Lorentz force, solar radiation pressure, and plasma drag. Particles can be either confined in the arcs due to corotational resonance with Mimas, as their source moons (Spitale et al., 2006; Cooper et al., 2008; Hedman et al., 2009), or pushed outward by plasma drag. Particle sinks are recollisions with the source moon, co...

  14. Ideas on DC-DC Converters for Delivery of Low Voltage and High Currents for the SLHC / ILC Detector Electronics in Magnetic field and Radiation environments

    CERN Document Server

    Dhawan, Satish; Neal, H; Sumner, R; Weber, M; Weber, R

    2007-01-01

    For more efficient power transport to the electronics embedded inside large colliding beam detectors, we explore the feasibility of supplying 48 Volts DC and using local DCDC conversion to 2 V (or lower, depending upon on the lithography of the embedded electronics) using switch mode regulators located very close to the front end electronics. These devices will be exposed to high radiation and high magnetic fields, 10 – 100 Mrads and 2 - 4 Tesla at the SLHC, and 20 Krads and 6 Tesla at the ILC.

  15. Intracerebral delivery of 5-iodo-2'-deoxyuridine in combination with synchrotron stereotactic radiation for the therapy of the F98 glioma.

    OpenAIRE

    Rousseau, Julia; Adam, Jean-François; Deman, Pierre; Wu, Ting Di; Guerquin-Kern, Jean-Luc; Gouget, Barbara; Barth, Rolf,; Estève, François; Elleaume, Hélène

    2009-01-01

    Iodine-enhanced synchrotron stereotactic radiotherapy takes advantage of the radiation dose-enhancement produced by high-Z elements when irradiated with mono-energetic beams of synchrotron X-rays. In this study it has been investigated whether therapeutic efficacy could be improved using a thymidine analogue, 5-iodo-2'-deoxyuridine (IUdR), as a radiosentizing agent. IUdR was administered intracerebrally over six days to F98 glioma-bearing rats using Alzet osmotic pumps, beginning seven days a...

  16. Dead cells in melanoma tumors provide abundant antigen for targeted delivery of ionizing radiation by a mAb to melanin

    OpenAIRE

    Dadachova, Ekaterina; Nosanchuk, Joshua D.; Shi, Li; Schweitzer, Andrew D.; Frenkel, Annie; Nosanchuk, Jerome S.; Casadevall, Arturo

    2004-01-01

    Melanoma is a cancer with a rising incidence, and metastatic disease is almost always lethal. We investigated the feasibility of targeting melanin, an intracellular melanocyte pigment, to deliver cytotoxic radiation to human melanoma cells in vivo by using a melanin-binding mAb (6D2). Nude mice bearing MNT1 pigmented human melanoma tumors were treated with mAb 6D2 labeled with 1.5 mCi (1 Ci = 37 GBq) of the β-emitter 188-Rhenium (188Re) and manifested inhibition of tumor growth and prolonged ...

  17. Making Conductive Polymers By Arc Tracking

    Science.gov (United States)

    Daech, Alfred F.

    1992-01-01

    Experimental technique for fabrication of electrically conductive polymeric filaments based on arc tracking, in which electrical arc creates conductive carbon track in material that initially was insulator. Electrically conductive polymeric structures made by arc tracking aligned along wire on which formed. Alignment particularly suited to high conductivity and desirable in materials intended for testing as candidate superconductors.

  18. Dosimetry Comparison between Volumetric Modulated Arc Therapy with RapidArc and Fixed Field Dynamic IMRT for Local-Regionally Advanced Nasopharyngeal Carcinoma

    Institute of Scientific and Technical Information of China (English)

    Bao-min Zheng; Xiao-xia Dong; Hao Wu; You-jia Duan; Shu-kui Han; Yan Sun

    2011-01-01

    Objective:A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC).Methods:The CT scan data sets of 20 patients of locally advanced NPC were selected randomly.The plans were managed using volumetric modulated arc with RapidArc and fixed nine-field coplanar dynamic intensity-modulated radiotherapy (IMRT) for these patients.The dosimetry of the planning target volumes (PTV),the organs at risk (OARs) and the healthy tissue were evaluated.The dose prescription was set to 70 Gy to the primary tumor and 60 Gy to the clinical target volumes (CTV) in 33 fractions.Each fraction applied daily,five fractions per week.The monitor unit (MU) values and the delivery time were scored to evaluate the expected treatment efficiency.Results:Both techniques had reached clinical treatment's requirement.The mean dose (Dmean),maximum dose (Dmax) and minimum dose (Dmin) in RapidArc and fixed field IMRT for PTV were 68.4±0.6 Gy,74.8±0.9 Gy and 56.8±1.1 Gy; and 67.6±0.6 Gy,73.8±0.4 Gy and 57.5±0.6 Gy (P<0.05),respectively.Homogeneity index was 78.85±1.29 in RapidArc and 80.34±0.54 (P<0.05) in IMRT.The conformity index (CI:95%) was 0.78±0.01 for both techniques (P>0.05).Compared to IMRT,RapidArc allowed a reduction of Dmean to the brain stem,mandible and optic nerves of 14.1% (P<0.05),5.6% (P<0.05) and 12.2% (P<0.05),respectively.For the healthy tissue and the whole absorbed dose,Dmean of RapidArc was reduced by 3.6% (P<0.05),and 3.7% (P<0.05),respectively.The Dmean to the parotids,the spinal cord and the lens had no statistical difference among them.The mean MU values of RapidArc and IMRT were 550 and 1,379.The mean treatment time of RapidArc and IMRT was 165 s and 447 s.Compared to IMRT,the delivery time and the MU values of RapidArc were reduced by 63% and 60%,respectively.Conclusion:For locally advanced NPC,both RapidArc and IMRT reached

  19. Premature delivery

    Directory of Open Access Journals (Sweden)

    Bernardita Donoso Bernales

    2012-09-01

    Full Text Available Preterm delivery is the single most important cause of perinatal morbidity and mortality. In Chile, preterm births have increased in the past decade, although neonatal morbidity and mortality attributable to it shows a downward trend, thanks to improvements in neonatal care of premature babies, rather than the success of obstetric preventive and therapeutic strategies. This article describes clinical entities, disease processes and conditions that constitute predisposing factors of preterm birth, as well as an outline for the prevention and clinical management of women at risk of preterm birth.

  20. Contouring Guidelines for the Axillary Lymph Nodes for the Delivery of Radiation Therapy in Breast Cancer: Evaluation of the RTOG Breast Cancer Atlas

    Energy Technology Data Exchange (ETDEWEB)

    Gentile, Michelle S. [Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center of Northwestern University, Chicago, Illinois (United States); Usman, Asad A.; Neuschler, Erin I. [Department of Radiology, Robert H. Lurie Comprehensive Cancer Center of Northwestern University, Chicago, Illinois (United States); Sathiaseelan, Vythialinga; Hayes, John P. [Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center of Northwestern University, Chicago, Illinois (United States); Small, William, E-mail: WMSMALL@lumc.edu [Department of Radiation Oncology, Loyola University, Chicago, Illinois (United States)

    2015-10-01

    Purpose: The purpose of this study was to identify the axillary lymph nodes on pretreatment diagnostic computed tomography (CT) of the chest to determine their position relative to the anatomic axillary borders as defined by the Radiation Therapy Oncology Group (RTOG) breast cancer atlas for radiation therapy planning. Methods and Materials: Pretreatment diagnostic CT chest scans available for 30 breast cancer patients with clinically involved lymph nodes were fused with simulation CT. Contouring of axillary levels I, II, and III according to the RTOG guidelines was performed. Measurements were made from the area of distal tumor to the anatomic borders in 6 dimensions for each level. Results: Of the 30 patients, 100%, 93%, and 37% had clinical involvement of levels I, II, and III, respectively. The mean number of lymph nodes dissected was 13.6. The mean size of the largest lymph node was 2.4 cm. Extracapsular extension was seen in 23% of patients. In 97% of patients, an aspect of the involved lymph node lay outside of the anatomic border of a level. In 80% and 83% of patients, tumor extension was seen outside the cranial (1.78 ± 1.0 cm; range, 0.28-3.58 cm) and anterior (1.27 ± 0.92 cm; range, 0.24-3.58 cm) borders of level I, respectively. In 80% of patients, tumor extension was seen outside the caudal border of level II (1.36 ± 1.0 cm, range, 0.27-3.86 cm), and 0% to 33% of patients had tumor extension outside the remaining borders of all levels. Conclusions: To cover 95% of lymph nodes at the cranial and anterior borders of level I, an additional clinical target volume margin of 3.78 cm and 3.11 cm, respectively, is necessary. The RTOG guidelines may be insufficient for coverage of axillary disease in patients with clinical nodal involvement who are undergoing neoadjuvant chemotherapy, incomplete axillary dissection, or treatment with intensity modulated radiation therapy. In patients with pretreatment diagnostic CT chest scans, fusion with

  1. Tectonomagmatism in continental arcs: evidence from the Sark arc complex

    Science.gov (United States)

    Gibbons, Wes; Moreno, Teresa

    2002-07-01

    The island of Sark (Channel Islands, UK) exposes syntectonic plutons and country rock gneisses within a Precambrian (Cadomian) continental arc. This Sark arc complex records sequential pulses of magmatism over a period of 7 Ma (ca. 616-609 Ma). The earliest intrusion (ca. 616 Ma) was a composite sill that shows an ultramafic base overlain by a magma-mingled net vein complex subsequently deformed at near-solidus temperatures into the amphibolitic and tonalitic Tintageu banded gneisses. The deformation was synchronous with D 2 deformation of the paragneissic envelope, with both intrusion and country rock showing flat, top-to-the-south LS fabrics. Later plutonism injected three homogeneous quartz diorite-granodiorite sheets: the Creux-Moulin pluton (150-250 m; ca. 614 Ma), the Little Sark pluton (>700 m; 611 Ma), and the Northern pluton (>500 m; 609 Ma). Similar but thinner sheets in the south (Derrible-Hogsback-Dixcart) and west (Port es Saies-Brecqhou) are interpreted as offshoots from the Creux-Moulin pluton and Little Sark pluton, respectively. All these plutons show the same LS fabric seen in the older gneisses, with rare magmatic fabrics and common solid state fabrics recording syntectonic crystallisation and cooling. The cooling rate increased rapidly with decreasing crystallisation age: >9 Ma for the oldest intrusion to cool to lower amphibolite conditions, 7-8 Ma for the Creux Moulin pluton, 5-6 Ma for the Little Sark pluton, and 10 -14 s -1) that focussed extensional deformation into the Sark area. The increased rates of extension allowed ingress of the subsequent quartz diorite-granodiorite sheets, although strain rate slowly declined as the whole complex cooled during exhumation. The regional architecture of syntectonic Cadomian arc complexes includes flat-lying "Sark-type" and steep "Guernsey-type" domains produced synchronously in shear zone networks induced by oblique subduction: a pattern seen in other continental arcs such as that running from Alaska

  2. A modular approach to intensity-modulated arc therapy optimization with noncoplanar trajectories

    Science.gov (United States)

    Papp, Dávid; Bortfeld, Thomas; Unkelbach, Jan

    2015-07-01

    Utilizing noncoplanar beam angles in volumetric modulated arc therapy (VMAT) has the potential to combine the benefits of arc therapy, such as short treatment times, with the benefits of noncoplanar intensity modulated radiotherapy (IMRT) plans, such as improved organ sparing. Recently, vendors introduced treatment machines that allow for simultaneous couch and gantry motion during beam delivery to make noncoplanar VMAT treatments possible. Our aim is to provide a reliable optimization method for noncoplanar isocentric arc therapy plan optimization. The proposed solution is modular in the sense that it can incorporate different existing beam angle selection and coplanar arc therapy optimization methods. Treatment planning is performed in three steps. First, a number of promising noncoplanar beam directions are selected using an iterative beam selection heuristic; these beams serve as anchor points of the arc therapy trajectory. In the second step, continuous gantry/couch angle trajectories are optimized using a simple combinatorial optimization model to define a beam trajectory that efficiently visits each of the anchor points. Treatment time is controlled by limiting the time the beam needs to trace the prescribed trajectory. In the third and final step, an optimal arc therapy plan is found along the prescribed beam trajectory. In principle any existing arc therapy optimization method could be incorporated into this step; for this work we use a sliding window VMAT algorithm. The approach is demonstrated using two particularly challenging cases. The first one is a lung SBRT patient whose planning goals could not be satisfied with fewer than nine noncoplanar IMRT fields when the patient was treated in the clinic. The second one is a brain tumor patient, where the target volume overlaps with the optic nerves and the chiasm and it is directly adjacent to the brainstem. Both cases illustrate that the large number of angles utilized by isocentric noncoplanar VMAT plans

  3. Simulation of Magnetically Dispersed Arc Plasma

    Institute of Scientific and Technical Information of China (English)

    白冰; 查俊; 张晓宁; 王城; 夏维东

    2012-01-01

    Magnetically dispersed arc plasma exhibits typically dispersed uniform arc column as well as diffusive cathode root and diffusive anode root. In this paper magnetically dispersed arc plasma coupled with solid cathode is numerically simulated by the simplified cathode sheath model of LOWKE . The numerical simulation results in argon show that the maximum value of arc root current density on the cathode surface is 3.5×10^7 A/m^2), and the maximum value of energy flux on the cathode surface is 3× 10^7 J/m^2, both values are less than the average values of a contracted arc, respectively.

  4. A mechanism that triggers double arcing during plasma arc cutting

    Energy Technology Data Exchange (ETDEWEB)

    Nemchinsky, Valerian, E-mail: nemchinsky@bellsouth.ne [Keiser University, Fort Lauderdale, FL 33309 (United States)

    2009-10-21

    Double arcing (DA) is a phenomenon when a transferred arc, flowing inside an electrically insulated nozzle, breaks into two separate arcs: one that connects the cathode and the nozzle and another that connects the nozzle and a work-piece. It is a commonly accepted opinion that the reason for DA is high voltage drop in the plasma inside the nozzle. However, the specific mechanism that triggers the DA development is not clear. In this paper, we propose such a mechanism. Dielectric films deposited inside the nozzle's orifice play the key role in this mechanism. These films are charged by ion current from plasma. A strong electric field is created inside the film and at the boundary of the film and clean metal of the nozzle. This gives rise to a thermo-field electron emission from the clean metal that borders the film. Emitted electrons are accelerated at the voltage drop between the nozzle and plasma. These electrons produce extra ions, which in turn move back to the film and additionally charge it. This sequence of events leads to explosive instability if the voltage drop inside the nozzle is high enough. Experiments to check the proposed mechanism are suggested.

  5. High-dose radiotherapy in inoperable nonsmall cell lung cancer: comparison of volumetric modulated arc therapy, dynamic IMRT and 3D conformal radiotherapy.

    Science.gov (United States)

    Bree, Ingrid de; van Hinsberg, Mariëlle G E; van Veelen, Lieneke R

    2012-01-01

    Conformal 3D radiotherapy (3D-CRT) combined with chemotherapy for inoperable non-small cell lung cancer (NSCLC) to the preferable high dose is often not achievable because of dose-limiting organs. This reduces the probability of regional tumor control. Therefore, the surplus value of using intensity-modulated radiation therapy (IMRT) techniques, specifically volumetric modulated arc therapy (RapidArc [RA]) and dynamic IMRT (d-IMRT) has been investigated. RA and d-IMRT plans were compared with 3D-CRT treatment plans for 20 patients eligible for concurrent high-dose chemoradiotherapy, in whom a dose of 60 Gy was not achievable. Comparison of dose delivery in the target volume and organs at risk was carried out by evaluating 3D dose distributions and dose-volume histograms. Quality of the dose distribution was assessed using the inhomogeneity and conformity index. For most patients, a higher dose to the target volume can be delivered using RA or d-IMRT; in 15% of the patients a dose ≥60 Gy was possible. Both IMRT techniques result in a better conformity of the dose (p < 0.001). There are no significant differences in homogeneity of dose in the target volume. IMRT techniques for NSCLC patients allow higher dose to the target volume, thus improving regional tumor control. PMID:22459649

  6. High-dose radiotherapy in inoperable nonsmall cell lung cancer: Comparison of volumetric modulated arc therapy, dynamic IMRT and 3D conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bree, Ingrid de, E-mail: i.de.bree@zrti.nl [Zeeuws Radiotherapeutisch Instituut, Vlissingen (Netherlands); Hinsberg, Marieelle G.E. van; Veelen, Lieneke R. van [Zeeuws Radiotherapeutisch Instituut, Vlissingen (Netherlands)

    2012-01-01

    Conformal 3D radiotherapy (3D-CRT) combined with chemotherapy for inoperable non-small cell lung cancer (NSCLC) to the preferable high dose is often not achievable because of dose-limiting organs. This reduces the probability of regional tumor control. Therefore, the surplus value of using intensity-modulated radiation therapy (IMRT) techniques, specifically volumetric modulated arc therapy (RapidArc [RA]) and dynamic IMRT (d-IMRT) has been investigated. RA and d-IMRT plans were compared with 3D-CRT treatment plans for 20 patients eligible for concurrent high-dose chemoradiotherapy, in whom a dose of 60 Gy was not achievable. Comparison of dose delivery in the target volume and organs at risk was carried out by evaluating 3D dose distributions and dose-volume histograms. Quality of the dose distribution was assessed using the inhomogeneity and conformity index. For most patients, a higher dose to the target volume can be delivered using RA or d-IMRT; in 15% of the patients a dose {>=}60 Gy was possible. Both IMRT techniques result in a better conformity of the dose (p < 0.001). There are no significant differences in homogeneity of dose in the target volume. IMRT techniques for NSCLC patients allow higher dose to the target volume, thus improving regional tumor control.

  7. High-dose radiotherapy in inoperable nonsmall cell lung cancer: Comparison of volumetric modulated arc therapy, dynamic IMRT and 3D conformal radiotherapy

    International Nuclear Information System (INIS)

    Conformal 3D radiotherapy (3D-CRT) combined with chemotherapy for inoperable non–small cell lung cancer (NSCLC) to the preferable high dose is often not achievable because of dose-limiting organs. This reduces the probability of regional tumor control. Therefore, the surplus value of using intensity-modulated radiation therapy (IMRT) techniques, specifically volumetric modulated arc therapy (RapidArc [RA]) and dynamic IMRT (d-IMRT) has been investigated. RA and d-IMRT plans were compared with 3D-CRT treatment plans for 20 patients eligible for concurrent high-dose chemoradiotherapy, in whom a dose of 60 Gy was not achievable. Comparison of dose delivery in the target volume and organs at risk was carried out by evaluating 3D dose distributions and dose-volume histograms. Quality of the dose distribution was assessed using the inhomogeneity and conformity index. For most patients, a higher dose to the target volume can be delivered using RA or d-IMRT; in 15% of the patients a dose ≥60 Gy was possible. Both IMRT techniques result in a better conformity of the dose (p < 0.001). There are no significant differences in homogeneity of dose in the target volume. IMRT techniques for NSCLC patients allow higher dose to the target volume, thus improving regional tumor control.

  8. Multistage CSR microbunching gain development in transport or recirculation arcs

    CERN Document Server

    Tsai, Cheng-Ying; Li, Rui; Tennant, Chris

    2015-01-01

    Coherent synchrotron radiation (CSR) induced microbunching instability has been one of the most challenging issues in the design of modern accelerators. A linear Vlasov solver has been developed [1] and applied to investigate the physical processes of microbunching gain amplification for several example lattices [2]. In this paper, by further extending the concept of stage gain as proposed by Huang and Kim [3], we develop a method to characterize the microbunching development in terms of stage orders that allow the quantitative comparison of optics impacts on microbunching gain for different lattices. We find that the microbunching instability in our demonstrated arcs has a distinguishing feature of multistage amplification (e.g, up to 6th stage amplification for our example transport arcs, in contrast to two-stage amplification for a typical 4-dipole bunch compressor chicane). We also try to connect lattice optics pattern with the obtained stage gain functions by a physical interpretation. This Vlasov analys...

  9. Zircon Recycling in Arc Intrusions

    Science.gov (United States)

    Miller, J.; Barth, A.; Matzel, J.; Wooden, J.; Burgess, S.

    2008-12-01

    Recycling of zircon has been well established in arc intrusions and arc volcanoes, but a better understanding of where and how zircons are recycled can help illuminate how arc magma systems are constructed. To that end, we are conducting age, trace element (including Ti-in-zircon temperatures; TzrnTi) and isotopic studies of zircons from the Late Cretaceous (95-85 Ma) Tuolumne Intrusive Suite (TIS) in the Sierra Nevada Batholith (CA). Within the TIS zircons inherited from ancient basement sources and/or distinctly older host rocks are uncommon, but recycled zircon antecrysts from earlier periods of TIS-related magmatism are common and conspicuous in the inner and two most voluminous units of the TIS, the Half Dome and Cathedral Peak Granodiorites. All TIS units have low bulk Zr ([Zr]825°C), [Zr] in the TIS is a factor of 2 to 3 lower than saturation values. Low [Zr] in TIS rocks might be attributed to a very limited supply of zircon in the source, by disequilibrium melting and rapid melt extraction [1], by melting reactions involving formation of other phases that can incorporate appreciable Zr [2], or by removal of zircon at an earlier stage of magma evolution. Based on a preliminary compilation of literature data, low [Zr] is common to Late Cretaceous N.A. Cordilleran granodioritic/tonalitic intrusions (typically Tzrnsat [3]. A corollary is that slightly older zircon antecrysts that are common in the inner units of the TIS could be considered inherited if they are derived from remelting of slightly older intrusions. Remelting at such low temperatures in the arc would require a source of external water. Refs: [1] Sawyer, J.Pet 32:701-738; [2] Fraser et al, Geology 25:607-610; [3] Harrison et al, Geology 35:635- 638

  10. Minor arcs for Goldbach's problem

    CERN Document Server

    Helfgott, H A

    2012-01-01

    The ternary Goldbach conjecture states that every odd number $n\\geq 7$ is the sum of three primes. The estimation of sums of the form $\\sum_{p\\leq x} e(\\alpha p)$, $\\alpha = a/q + O(1/q^2)$, has been a central part of the main approach to the conjecture since (Vinogradov, 1937). Previous work required $q$ or $x$ to be too large to make a proof of the conjecture for all $n$ feasible. The present paper gives new bounds on minor arcs and the tails of major arcs. For $q\\geq 4\\cdot 10^6$, these bounds are of the strength needed to solve the ternary Goldbach conjecture. Only the range $q\\in \\lbrack 10^5, 4\\cdot 10^6\\rbrack$ remains to be checked, possibly by brute force, before the conjecture is proven for all $n$. The new bounds are due to several qualitative improvements. In particular, this paper presents a general method for reducing the cost of Vaughan's identity, as well as a way to exploit the tails of minor arcs in the context of the large sieve.

  11. A comparison of liver protection among 3-D conformal radiotherapy, intensity-modulated radiotherapy and RapidArc for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    The analysis was designed to compare dosimetric parameters among 3-D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and RapidArc (RA) to identify which can achieve the lowest risk of radiation-induced liver disease (RILD) for hepatocellular carcinoma (HCC). Twenty patients with HCC were enrolled in this study. Dosimetric values for 3DCRT, IMRT, and RA were calculated for total dose of 50 Gy/25f. The percentage of the normal liver volume receiving >40, >30, >20, >10, and >5 Gy (V40, V30, V20, V10 and V5) were evaluated to determine liver toxicity. V5, V10, V20, V30 and Dmean of liver were compared as predicting parameters for RILD. Other parameters included the conformal index (CI), homogeneity index (HI), and hot spot (V110%) for the planned target volume (PTV) as well as the monitor units (MUs) for plan efficiency, the mean dose (Dmean) for the organs at risk (OARs) and the maximal dose at 1% volume (D1%) for the spinal cord. The Dmean of IMRT was higher than 3DCRT (p = 0.045). For V5, there was a significant difference: RA > IMRT >3DCRT (p <0.05). 3DCRT had a lower V10 and higher V20, V30 values for liver than RA (p <0.05). RA and IMRT achieved significantly better CI and lower V110% values than 3DCRT (p <0.05). RA had better HI, lower MUs and shorter delivery time than 3DCRT or IMRT (p <0.05). For right lobe tumors, RapidArc may have the lowest risk of RILD with the lowest V20 and V30 compared with 3DCRT or IMRT. For diameters of tumors >8 cm in our study, the value of Dmean for 3DCRT was lower than IMRT or RapidArc. This may indicate that 3DCRT is more suitable for larger tumors

  12. Application of Steenbeck's minimum principle for three-dimensional modelling of DC arc plasma torches

    International Nuclear Information System (INIS)

    In this paper, physical/mathematical models for the three-dimensional, quasi-steady modelling of the plasma flow and heat transfer inside a non-transferred DC arc plasma torch are described in detail. The Steenbeck's minimum principle (Finkelnburg W and Maecker H 1956 Electric arcs and thermal plasmas Encyclopedia of Physics vol XXII (Berlin: Springer)) is employed to determine the axial position of the anode arc-root at the anode surface. This principle postulates a minimum arc voltage for a given arc current, working gas flow rate, and torch configuration. The modelling results show that the temperature and flow fields inside the DC non-transferred arc plasma torch show significant three-dimensional features. The predicted anode arc-root attachment position and the arc shape by employing Steenbeck's minimum principle are reasonably consistent with experimental observations. The thermal efficiency and the torch power distribution are also calculated in this paper. The results show that the thermal efficiency of the torch always ranges from 30% to 45%, i.e. more than half of the total power input is taken away by the cathode and anode cooling water. The special heat transfer mechanisms at the plasma-anode interface, such as electron condensation, electron enthalpy and radiative heat transfer from the bulk plasma to the anode inner surface, are taken into account in this paper. The calculated results show that besides convective heat transfer, the contributions of electron condensation, electron enthalpy and radiation to the anode heat transfer are also important (∼30% for parameter range of interest in this paper). Additional effects, such as the non-local thermodynamic equilibrium plasma state near the electrodes, the transient phenomena, etc, need to be considered in future physical/mathematical models, including corresponding measurements

  13. TH-C-12A-01: Develop a Patient-Specific QA Program for Radiation Therapy with On-Board MRI

    International Nuclear Information System (INIS)

    Purpose: This work describes development of the first patient-specific quality assurance (QA) program for magnetic resonance imaging guided radiation therapy (MR-IGRT). Methods: The program consisted of following components: 1) multipoint ionization chamber (IC) measurement using a 15 cm3 cubic phantom, 2) 2D stacked radiographic film dosimetry using a 30×30×20 cm3 phantom with multiple inserted ICs, 3) 3D ArcCHECK measurement with a centrally inserted IC, 4) machine delivery file verification, 5) 3D Monte-Carlo dose re-calculation with machine delivery file and phantom CT, 6) 2-head mode delivery validation in case of a malfunctioning head, and 7) independent beam-on time calculation for non-IMRT fields. Both ADCL calibrated ICs and ArcCHECK were MRI compatible. Experimental data were analyzed for the first 10 patients treated at our institution. Results: The customized phantoms allowed measuring multiple points with ICs in one delivery. Absolute IC measurements were all within 3% in all phantom geometry/shape/material combinations. Despite known uncertainty associated with film dosimetry, passing rates greater than 90% were achieved in both absolute and composite modes using TG-129 criteria. Due to the simultaneous irradiation by three radiation sources, ArcCHECK was used as a 3D relative dosimeter with angular and energy dependences uncorrected. 95–100% passing rates were obtained and the centrally inserted IC measurement assured that the overall dose normalization was within 3%. Machine delivery file verification and MC recalculated dose to the phantom results showed 98–100% passing rates, providing opportunity of moving from gamma passing rates to patient DVHbased QA metrics. Same results were obtained for the 2-head delivery mode. Manual beam-on time calculation for non-IMRT fields showed better than 5% agreement. Conclusion: We have successfully developed the first MRIGRT patient specific QA program by adopting experimental and computational dosimetry

  14. Arc Root Attachment on the Anode Surface of Arc Plasma Torch Observed with a Novel Method

    Institute of Scientific and Technical Information of China (English)

    PAN Wen-Xia; LI Teng; MENG Xian; CHEN Xi; WU Cheng-Kang

    2005-01-01

    @@ The arc-root attachment on the anode surface of a dc non-transferred arc plasma torch has been successfullyobserved using a novel approach. A specially designed copper mirror with a boron nitride film coated on itssurface central-region is employed to avoid the effect of intensive light emitted from the arc column upon theobservation of weakly luminous arc root. It is found that the arc-root attachment is diffusive on the anode surfaceof the argon plasma torch, while constricted arc roots often occur when hydrogen or nitrogen is added into argonas the plasma-forming gas.

  15. Reappraisal of the Arc-Arc Collision in Taiwan

    Directory of Open Access Journals (Sweden)

    Tetsuzo Seno and Yoshiaki Kawanishi

    2009-01-01

    Full Text Available Al though it is evident that Taiwan has been formed by the collision of the west-facing Luzon arc with the Eurasian continental mar gin, _ main a lot of enigmas in this collision. The major ones are: (1 a trans form fault presently connecting the Manila and Ryukyu Trenches in the Philippine Sea _ Eurasia relative motion direction is missing, and in stead, the Ryukyu Trench ex tends near off shore E. Tai wan, (2 the western edge of the intermediate-depth seismicity associated with We pro pose a new model of the collision in Tai wan to re solve these enigmas, assuming that the southern Ryukyu forearc was mi grating to the south west with respect to Eurasia for the past several m.y. and the Luzon arc has been colliding with this actively migrating Ryukyu forearc. The northern most Luzon arc is divided into two parts by the NNW line directing along the Philippine Sea - Ryukyu forearc motion from its initial intersection point with the Ryukyu Trench; the part west of this line has been obducted on the Ryukyu forearc-Eurasian mar gin, producing the collision orogen in Taiwan, and the part east of it has been subducted beneath the Ryukyu forearc. This evolutionary scenario resolves enigmas (1 and (2 kinematically. This model also predicts that the South China Sea slab has to be torn by the west ward component of the motion of the subducting Philippine Sea slab to Eurasia. This would have brought large lateral compression in the shallow portion of the Philippine Sea slab at its western border, which might lead to buck ling of the slab causing the ob served undulated gravity anomaly.

  16. SU-E-J-269: Assessing the Precision of Dose Delivery in CBCT-Guided Stereotactic Body Radiation Therapy for Lung and Soft Tissue Metastatic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Parsai, S; Dalhart, A; Chen, C; Parsai, E; Pearson, D; Sperling, N; Reddy, K [University of Toledo Medical Center, Toledo, OH (United States)

    2014-06-01

    Purpose: Ensuring reproducibility of target localization is critical to accurate stereotactic body radiation treatment (SBRT) for lung and soft tissue metastatic lesions. To characterize interfraction variability in set-up and evaluate PTV margins utilized for SBRT, daily CBCTs were used to calculate delivered target and OAR doses compared to those expected from planning. Methods: CBCT images obtained prior to each fraction of SBRT for a lung and thyroid metastatic lesion were evaluated. The target CTV/ITV and OARs on each of 8 CBCT data sets were contoured. Using MIM fusion software and Pinnacle{sup 3} RTP system, delivered dose distribution was reconstructed on each CBCT, utilizing translational shifts performed prior to treatment. Actual delivered vs. expected doses received by target CTV/ITV and adjacent critical structures were compared to characterize accuracy of pre-treatment translational shifts and PTV margins. Results: The planned CTV/ITV D95% and V100% were 4595cGy and 91.47% for the lung lesion, and 3010cGy and 96.34% for the thyroid lesion. Based on CBCT analysis, actual mean D95% and V100% for lung ITV were 4542±344.4cGy and 91.54±3.45%; actual mean D95% and V100% for thyroid metastasis CTV were 3005±25.98cGy and 95.20±2.522%. For the lung lesion, ipsilateral lung V20, heart V32 (cc) and spinal cord (.03 cc) max were 110.15cc, 3.33cc, and 1680cGy vs. 110.27±14.79cc, 6.74±3.76cc, and 1711±46.56cGy for planned vs. delivered doses, respectively. For the thyroid metastatic lesion, esophagus V18, trachea (.03 cc) max, and spinal cord (.03 cc) max were 0.35cc, 2555cGy, and 850cGy vs. 0.16±0.13cc, 2147±367cGy, and 838±45cGy for planned vs. delivered treatments, respectively. Conclusion: Minimal variability in SBRT target lesion dose delivered based on pre-treatment CBCT-based translational shifts suggests tighter PTV margins may be considered to further decrease dose to surrounding critical structures. Guidelines for optimal target alignment during

  17. The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy

    International Nuclear Information System (INIS)

    To expand and test the dosimetric procedure, known as GLAaS, for amorphous silicon detectors to the RapidArc intensity modulated arc delivery with Varian infrastructures and to test the RapidArc dosimetric reliability between calculation and delivery. The GLAaS algorithm was applied and tested on a set of RapidArc fields at both low (6 MV) and high (18 MV) beam energies with a PV-aS1000 detector. Pilot tests for short arcs were performed on a 6 MV beam associated to a PV-aS500. RapidArc is a novel planning and delivery method in the category of intensity modulated arc therapies aiming to deliver highly modulated plans with variable MLC shapes, dose rate and gantry speed during rotation. Tests were repeated for entire (360 degrees) gantry rotations on composite dose plans and for short partial arcs (of ~6 or 12 degrees) to assess GLAaS and RapidArc mutual relationships on global and fine delivery scales. The gamma index concept of Low and the Modulation Index concept of Webb were applied to compare quantitatively TPS dose matrices and dose converted PV images. The Gamma Agreement Index computed for a Distance to Agreement of 3 mm and a Dose Difference (ΔD) of 3% was, as mean ± 1 SD, 96.7 ± 1.2% at 6 MV and 94.9 ± 1.3% at 18 MV, over the field area. These findings deteriorated slightly is ΔD was reduced to 2% (93.4 ± 3.2% and 90.1 ± 3.1%, respectively) and improved with ΔD = 4% (98.3 ± 0.8% and 97.3 ± 0.9%, respectively). For all tests a grid of 1 mm and the AAA photon dose calculation algorithm were applied. The spatial resolution of the PV-aS1000 is 0.392 mm/pxl. The Modulation Index for calculations resulted 17.0 ± 3.2 at 6 MV and 15.3 ± 2.7 at 18 MV while the corresponding data for measurements were: 18.5 ± 3.7 and 17.5 ± 3.7. Partial arcs findings were (for ΔD = 3%): GAI = 96.7 ± 0.9% for 6° rotations and 98.0 ± 1.1% for 12° rotations. The GLAaS method can be considered as a valid Quality Assurance tool for the verification of RapidArc fields

  18. The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy

    Directory of Open Access Journals (Sweden)

    Fogliata Antonella

    2008-09-01

    Full Text Available Abstract Background To expand and test the dosimetric procedure, known as GLAaS, for amorphous silicon detectors to the RapidArc intensity modulated arc delivery with Varian infrastructures and to test the RapidArc dosimetric reliability between calculation and delivery. Methods The GLAaS algorithm was applied and tested on a set of RapidArc fields at both low (6 MV and high (18 MV beam energies with a PV-aS1000 detector. Pilot tests for short arcs were performed on a 6 MV beam associated to a PV-aS500. RapidArc is a novel planning and delivery method in the category of intensity modulated arc therapies aiming to deliver highly modulated plans with variable MLC shapes, dose rate and gantry speed during rotation. Tests were repeated for entire (360 degrees gantry rotations on composite dose plans and for short partial arcs (of ~6 or 12 degrees to assess GLAaS and RapidArc mutual relationships on global and fine delivery scales. The gamma index concept of Low and the Modulation Index concept of Webb were applied to compare quantitatively TPS dose matrices and dose converted PV images. Results The Gamma Agreement Index computed for a Distance to Agreement of 3 mm and a Dose Difference (ΔD of 3% was, as mean ± 1 SD, 96.7 ± 1.2% at 6 MV and 94.9 ± 1.3% at 18 MV, over the field area. These findings deteriorated slightly is ΔD was reduced to 2% (93.4 ± 3.2% and 90.1 ± 3.1%, respectively and improved with ΔD = 4% (98.3 ± 0.8% and 97.3 ± 0.9%, respectively. For all tests a grid of 1 mm and the AAA photon dose calculation algorithm were applied. The spatial resolution of the PV-aS1000 is 0.392 mm/pxl. The Modulation Index for calculations resulted 17.0 ± 3.2 at 6 MV and 15.3 ± 2.7 at 18 MV while the corresponding data for measurements were: 18.5 ± 3.7 and 17.5 ± 3.7. Partial arcs findings were (for ΔD = 3%: GAI = 96.7 ± 0.9% for 6° rotations and 98.0 ± 1.1% for 12° rotations. Conclusion The GLAaS method can be considered as a valid

  19. Magnification Bias in Gravitational Arc Statistics

    CERN Document Server

    Caminha, G B; Makler, M; Mollerach, S; Roulet, E

    2013-01-01

    The statistics of arcs in galaxy clusters is a powerful probe of the inner parts of cluster structure and may provide complementary cosmological constraints. Although progresses involving simulations at the image level have improved the agreement among modelling and observations of arc abundance, there are still discrepancies regarding the redshift distribution of strong lensing clusters. Besides, fast "semi-analytic" methods still have to incorporate the success obtained with simulations. In this paper we discuss the contribution of magnification in gravitational arc statistics. Although lensing conserves surface brightness, the magnification (\\mu) increases the signal-to-noise ratio of the arcs in the images, enhancing their detectability. We present an approach to include this and other observational effects in semi-analytic calculations for arc statistics. The cross section for arc formation (\\sigma) is computed through a semi-analytic method based on the eigenvalue ratio of the magnification tensor. Usin...

  20. FASTER MUSE CSP ARC CONSISTENCY ALGORITHMS

    OpenAIRE

    Harper, Mary P.; White, Christopher M.; Helzerman, Randall A.; Hockema, Stephen A.

    1997-01-01

    MUSE CSP (Multiply SEgmented Constraint Satisfaction Problem) [5, 61 is an extension to the constraint satisfaction problem (CSP) which is especially useful for problems that segment into riultiple instances of CSP that share variables. In Belzerman and Harper [6], the concepts of MUSE node, arc, and path consistency were defined and algorithms for MUSE arc consistency, MUSE AC-1, and MUSE path consistency were developed. MUSE AC-1 is similar to the CSP arc consistency algorithm AC-4 [ l j ] ...

  1. Programming ArcGIS with Python cookbook

    CERN Document Server

    Pimpler, Eric

    2015-01-01

    Programming ArcGIS with Python Cookbook, Second Edition, is written for GIS professionals who wish to revolutionize their ArcGIS workflow with Python. Whether you are new to ArcGIS or a seasoned professional, you almost certainly spend time each day performing various geoprocessing tasks. This book will teach you how to use the Python programming language to automate these geoprocessing tasks and make you a more efficient and effective GIS professional.

  2. Effect of Gravity on Arc Shape in GTA Welding-for Low Electric Arc Current

    Institute of Scientific and Technical Information of China (English)

    Hidetoshi FUJII; Yosuke SUMI; Manabu TANAKA; Kiyoshi NOGI

    2003-01-01

    Gas tungsten arc (GTA) welding was performed both in a microgravity environment and in a terrestrial environment,and the arc shapes in both environments were compared. A microgravity condition was obtained using the free fallsystem at the Japan Microgravi

  3. Diffuse and spot mode of cathode arc attachments in an atmospheric magnetically rotating argon arc

    International Nuclear Information System (INIS)

    A model including the cathode, near-cathode region, and arc column was constructed. Specifically, a thermal perturbation layer at the arc fringe was calculated in order to couple sheath/presheath modelling with typical arc column modelling. Comparative investigation of two modes of attachment of a dc (100, 150, 200 A) atmospheric-pressure arc in argon to a thermionic cathode made of pure tungsten was conducted. Computational data revealed that there exists two modes of arc discharge: the spot mode, which has an obvious cathode surface temperature peak in the arc attachment centre; and the diffuse mode, which has a flat cathode surface temperature distribution and a larger arc attachment area. The modelling results of the arc attachment agree with previous experimental observations for the diffuse mode. A further 3D simulation is obviously needed to investigate the non-axisymmetrical features, especially for the spot mode. (paper)

  4. Major arcs for Goldbach's problem

    OpenAIRE

    Helfgott, H. A.

    2013-01-01

    The ternary Goldbach conjecture states that every odd number $n\\geq 7$ is the sum of three primes. The estimation of the Fourier series $\\sum_{p\\leq x} e(\\alpha p)$ and related sums has been central to the study of the problem since Hardy and Littlewood (1923). Here we show how to estimate such Fourier series for $\\alpha$ in the so-called major arcs, i.e., for $\\alpha$ close to a rational of small denominator. This is part of the author's proof of the ternary Goldbach conjecture. In contrast ...

  5. Generalized hyperfocused arcs in $PG(2,p)$

    OpenAIRE

    Blokhuis, A Aart; Marino, G.; Mazzocca, F.

    2013-01-01

    A {\\em generalized hyperfocused arc} $\\mathcal H $ in $PG(2,q)$ is an arc of size $k$ with the property that the $k(k-1)/2$ secants can be blocked by a set of $k-1$ points not belonging to the arc. We show that if $q$ is a prime and $\\mathcal H$ is a generalized hyperfocused arc of size $k$, then $k=1,2$ or 4. Interestingly, this problem is also related to the (strong) cylinder conjecture [Ball S.: The polynomial method in Galois geometries, in Current research topics in Galois geometry, Chap...

  6. Stability of alternating current gliding arcs

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Salewski, Mirko; Leipold, Frank;

    2014-01-01

    A gliding arc is a quenched plasma that can be operated as a non-thermal plasma at atmospheric pressure and that is thus suitable for large-scale plasma surface treatment. For its practical industrial use the discharge should be extended stably in ambient air. A simple analytical calculation based...... on Ohm’s law indicates that the critical length of alternating current (AC) gliding arc discharge columns can be larger than that of a corresponding direct current (DC) gliding arc. This finding is supported by previously published images of AC and DC gliding arcs. Furthermore, the analysis shows...

  7. The Abundance of Large Arcs From CLASH

    Science.gov (United States)

    Xu, Bingxiao; Postman, Marc; Meneghetti, Massimo; Coe, Dan A.; Clash Team

    2015-01-01

    We have developed an automated arc-finding algorithm to perform a rigorous comparison of the observed and simulated abundance of large lensed background galaxies (a.k.a arcs). We use images from the CLASH program to derive our observed arc abundance. Simulated CLASH images are created by performing ray tracing through mock clusters generated by the N-body simulation calibrated tool -- MOKA, and N-body/hydrodynamic simulations -- MUSIC, over the same mass and redshift range as the CLASH X-ray selected sample. We derive a lensing efficiency of 15 ± 3 arcs per cluster for the X-ray selected CLASH sample and 4 ± 2 arcs per cluster for the simulated sample. The marginally significant difference (3.0 σ) between the results for the observations and the simulations can be explained by the systematically smaller area with magnification larger than 3 (by a factor of ˜4) in both MOKA and MUSIC mass models relative to those derived from the CLASH data. Accounting for this difference brings the observed and simulated arc statistics into full agreement. We find that the source redshift distribution does not have big impact on the arc abundance but the arc abundance is very sensitive to the concentration of the dark matter halos. Our results suggest that the solution to the "arc statistics problem" lies primarily in matching the cluster dark matter distribution.

  8. Metals purification by improved vacuum arc remelting

    Science.gov (United States)

    Zanner, Frank J.; Williamson, Rodney L.; Smith, Mark F.

    1994-12-13

    The invention relates to improved apparatuses and methods for remelting metal alloys in furnaces, particularly consumable electrode vacuum arc furnaces. Excited reactive gas is injected into a stationary furnace arc zone, thus accelerating the reduction reactions which purify the metal being melted. Additionally, a cooled condensation surface is disposed within the furnace to reduce the partial pressure of water in the furnace, which also fosters the reduction reactions which result in a purer produced ingot. Methods and means are provided for maintaining the stationary arc zone, thereby reducing the opportunity for contaminants evaporated from the arc zone to be reintroduced into the produced ingot.

  9. MO-C-BRD-01: SBRT I: Overview of Simulation, Planning, and Delivery

    International Nuclear Information System (INIS)

    SBRT is having a dramatic impact on radiation therapy of early-stage, locally advanced cancers. Treatment planning of SBRT is characterized by precise target volume delineation, highly conformal dose distribution, sharp dose gradient outside the target volume, and meticulous tumor motion management. Stringent dose volume constraints of SBRT require the treatment planning to be highly personalized. Not only the complete patient's medical information (anatomy, tumor size/shape/location/motion, breathing pattern, health status) should be taken into consideration during planning, but also a wide range of factors including imaging techniques (imaging modality, breathing control, immobilization, patient position, etc.), treatment planning techniques (3D-conformal, dynamic conformal arcs, IMRT, VMAT, etc.), image guidance techniques (CBCT, orthogonal X-Ray, fiducial marker tracking, fluoroscopy, etc.), and delivery techniques (FFF, gating, tracking, etc.). In addition, potential pitfalls may exist in SBRT techniques and processes, such as target volume error in 4DCT and image registration error in image guidance. How to manage these affecting factors to achieve optimal, personalized SBRT treatment plans remains a great challenge. In this proposal, we will review technologies, share experiences, and discuss strategies concerning SBRT simulation, planning, and delivery. Learning Objectives: Understand requirements and challenges of SBRT treatment planning Discuss information-driven strategies of developing optimal SBRT plans Discuss practical considerations and potential pitfalls of SBRT treatment planning

  10. Unstable behavior of anodic arc discharge for synthesis of nanomaterials

    Science.gov (United States)

    Gershman, Sophia; Raitses, Yevgeny

    2016-09-01

    A short carbon arc operating with a high ablation rate of the graphite anode exhibits a combined motion of the arc and the arc attachment to the anode. A characteristic time scale of this motion is in a 10‑3 s range. The arc exhibits a negative differential resistance before the arc motion occurs. Thermal processes in the arc plasma region interacting with the ablating anode are considered as possible causes of this unstable arc behavior. It is also hypothesized that the arc motion could potentially cause mixing of the various nanoparticles synthesized in the arc in the high ablation regime.

  11. The risk of cataract in relation to metal arc welding

    DEFF Research Database (Denmark)

    Slagor, Rebekka Michaelsen; La Cour, Morten; Bonde, Jens Peter

    2016-01-01

    .95–1.21] and the adjusted HR was 1.08 (95% CI 0.95–1.22). Age and diabetes were as expected strong risk factors. Conclusion: We found no increased risk of developing cataract among Danish metal welders who worked with arc welding from 1950–1985. This may be attributed to the effectiveness of personal safety equipment.......Objectives: There are indications that solar ultraviolet radiation (UVR) increases the risk of cataract, but there is only circumstantial evidence that metal welding, an important occupational source of UVR exposure, is a risk factor. The objective of this study is to unravel if metal welding...

  12. Diagnosis of TIG welding based on ultraviolet radiation

    Institute of Scientific and Technical Information of China (English)

    Li Zhiyong; Gu Xiaoyan; Wang Bao

    2009-01-01

    Through collecting the radiation of tungsten inert gas (TIG) welding arc, the radiation distribution in ultraviolet zone is analyzed in order to study the variation rule of ultraviolet radiation versus welding condition. The explanation for the variation is also provided bused on spectral radiation theory of arc light. Furthermore, through analysis of disturbanee factors, the integral intensity signal of radiation in ultraviolet zone is applied for diagnosis of welding process. The spectral signal of ultraviolet radiation can reflect the disturbance factors and welding conditions, which can be used for online diagnosis of welding process.

  13. A comparison of the seismic structure of oceanic island arc crust and continental accreted arc terranes

    Science.gov (United States)

    Calvert, A. J.

    2015-12-01

    Amalgamation of island arcs and their accretion to pre-existing continents is considered to have been one of the primary mechanisms of continental growth over the last 3 Ga, with arc terranes identified within Late Archean, Proterozoic, and Phanerozoic continental crust. Crustal-scale seismic refraction surveys can provide P wave velocity models that can be used as a proxy for crustal composition, and although they indicate some velocity variation in accreted arcs, these terranes have significantly lower velocities, and are hence significantly more felsic, than modern island arcs. Modern oceanic arcs exhibit significant variations in crustal thickness, from as little as 10 km in the Bonin arc to 35 km in the Aleutian and northern Izu arcs. Although globally island arcs appear to have a mafic composition, intermediate composition crust is inferred in central America and parts of the Izu arc. The absence of a sharp velocity contrast at the Moho appears to be a first order characteristic of island arc crust, and indicates the existence of a broad crust-mantle transition zone. Multichannel seismic reflection surveys complement refraction surveys by revealing structures associated with variations in density and seismic velocity at the scale of a few hundred meters or less to depths of 60 km or more. Surveys from the Mariana and Aleutian arcs show that modern middle and lower arc crust is mostly non-reflective, but reflections are observed from depths 5-25 km below the refraction Moho suggesting the localized presence of arc roots that may comprise gabbro, garnet gabbro, and pyroxenite within a broad transition from mafic lower crust to ultramafic mantle. Such reflective, high velocity roots are likely separated from the overlying arc crust prior to, or during arc-continent collision, and seismic reflections within accreted arc crust document the collisional process and final crustal architecture.

  14. Micro-arcing and arc erosion minimization using a DC hybrid switching device

    OpenAIRE

    Swingler, J.; McBride, J. W.

    2008-01-01

    Hybrid switching devices utilize the advantages of both conventional electrical contacts and solid state electronics to minimize arcing during opening and closing operations. This can result in higher reliability and reduces the need for high cost specialist contact materials. The hybrid switch does not eliminate arcing completely, due to the inductive nature of circuits; micro-arcing is known to occur. An experimental dc hybrid switching device is introduced which minimizes arcing for 42 ...

  15. Targeted Drug Delivery in Pancreatic Cancer

    Science.gov (United States)

    Yu, Xianjun; Zhang, Yuqing; Chen, Changyi; Yao, Qizhi; Li, Min

    2009-01-01

    Effective drug delivery in pancreatic cancer treatment remains a major challenge. Because of the high resistance to chemo and radiation therapy, the overall survival rate for pancreatic cancer is extremely low. Recent advances in drug delivery systems hold great promise for improving cancer therapy. Using liposomes, nanoparticles, and carbon nanotubes to deliver cancer drugs and other therapeutic agents such as siRNA, suicide gene, oncolytic virus, small molecule inhibitor and antibody has been a success in recent pre-clinical trials. However, how to improve the specificity and stability of the delivered drug using ligand or antibody directed delivery represent a major problem. Therefore, developing novel, specific, tumor-targeted drug delivery systems is urgently needed for this terrible disease. This review summarizes the current progress on targeted drug delivery in pancreatic cancer, and provides important information on potential therapeutic targets for pancreatic cancer treatment. PMID:19853645

  16. Reverse-Contrast Imaging and Targeted Radiation Therapy of Advanced Pancreatic Cancer Models

    Energy Technology Data Exchange (ETDEWEB)

    Thorek, Daniel L.J., E-mail: dthorek1@jhmi.edu [Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, The Johns Hopkins School of Medicine, Baltimore, MD (United States); Kramer, Robin M. [Tri-Institutional Training Program in Laboratory Animal Medicine and Science, Memorial Sloan-Kettering Cancer Center (MSKCC), Weill Cornell Medical College, The Rockefeller University, New York, NY (United States); Chen, Qing; Jeong, Jeho; Lupu, Mihaela E. [Department of Medical Physics, MSKCC, New York, NY (United States); Lee, Alycia M.; Moynahan, Mary E.; Lowery, Maeve [Department of Medicine, MSKCC, New York, NY (United States); Ulmert, David [Molecular Pharmacology and Chemistry Program, MSKCC, New York, NY (United States); Department of Surgery (Urology), Skåne University Hospital, Malmö (Sweden); Zanzonico, Pat; Deasy, Joseph O.; Humm, John L. [Department of Medical Physics, MSKCC, New York, NY (United States); Russell, James, E-mail: russellj@mskcc.org [Department of Medical Physics, MSKCC, New York, NY (United States)

    2015-10-01

    Purpose: To evaluate the feasibility of delivering experimental radiation therapy to tumors in the mouse pancreas. Imaging and treatment were performed using combined CT (computed tomography)/orthovoltage treatment with a rotating gantry. Methods and Materials: After intraperitoneal administration of radiopaque iodinated contrast, abdominal organ delineation was performed by x-ray CT. With this technique we delineated the pancreas and both orthotopic xenografts and genetically engineered disease. Computed tomographic imaging was validated by comparison with magnetic resonance imaging. Therapeutic radiation was delivered via a 1-cm diameter field. Selective x-ray radiation therapy of the noninvasively defined orthotopic mass was confirmed using γH2AX staining. Mice could tolerate a dose of 15 Gy when the field was centered on the pancreas tail, and treatment was delivered as a continuous 360° arc. This strategy was then used for radiation therapy planning for selective delivery of therapeutic x-ray radiation therapy to orthotopic tumors. Results: Tumor growth delay after 15 Gy was monitored, using CT and ultrasound to determine the tumor volume at various times after treatment. Our strategy enables the use of clinical radiation oncology approaches to treat experimental tumors in the pancreas of small animals for the first time. We demonstrate that delivery of 15 Gy from a rotating gantry minimizes background healthy tissue damage and significantly retards tumor growth. Conclusions: This advance permits evaluation of radiation planning and dosing parameters. Accurate noninvasive longitudinal imaging and monitoring of tumor progression and therapeutic response in preclinical models is now possible and can be expected to more effectively evaluate pancreatic cancer disease and therapeutic response.

  17. Reverse-Contrast Imaging and Targeted Radiation Therapy of Advanced Pancreatic Cancer Models

    International Nuclear Information System (INIS)

    Purpose: To evaluate the feasibility of delivering experimental radiation therapy to tumors in the mouse pancreas. Imaging and treatment were performed using combined CT (computed tomography)/orthovoltage treatment with a rotating gantry. Methods and Materials: After intraperitoneal administration of radiopaque iodinated contrast, abdominal organ delineation was performed by x-ray CT. With this technique we delineated the pancreas and both orthotopic xenografts and genetically engineered disease. Computed tomographic imaging was validated by comparison with magnetic resonance imaging. Therapeutic radiation was delivered via a 1-cm diameter field. Selective x-ray radiation therapy of the noninvasively defined orthotopic mass was confirmed using γH2AX staining. Mice could tolerate a dose of 15 Gy when the field was centered on the pancreas tail, and treatment was delivered as a continuous 360° arc. This strategy was then used for radiation therapy planning for selective delivery of therapeutic x-ray radiation therapy to orthotopic tumors. Results: Tumor growth delay after 15 Gy was monitored, using CT and ultrasound to determine the tumor volume at various times after treatment. Our strategy enables the use of clinical radiation oncology approaches to treat experimental tumors in the pancreas of small animals for the first time. We demonstrate that delivery of 15 Gy from a rotating gantry minimizes background healthy tissue damage and significantly retards tumor growth. Conclusions: This advance permits evaluation of radiation planning and dosing parameters. Accurate noninvasive longitudinal imaging and monitoring of tumor progression and therapeutic response in preclinical models is now possible and can be expected to more effectively evaluate pancreatic cancer disease and therapeutic response

  18. Feedback Linearization Based Arc Length Control for Gas Metal Arc Welding

    DEFF Research Database (Denmark)

    Thomsen, Jesper Sandberg

    2005-01-01

    In this paper a feedback linearization based arc length controller for gas metal arc welding (GMAW) is described. A nonlinear model describing the dynamic arc length is transformed into a system where nonlinearities can be cancelled by a nonlinear state feedback control part, and thus, leaving only...

  19. Fast approximate delivery of fluence maps: the VMAT case

    CERN Document Server

    Balvert, Marleen

    2016-01-01

    In this article we provide a method to generate the trade-off between delivery time and fluence map matching quality for volumetric modulated arc therapy (VMAT). At the heart of our method lies a mathematical programming model that, for a given duration of delivery, optimizes leaf trajectories and dose rates such that the desired fluence map is reproduced as well as possible. This model was presented for the single map case in a companion paper (Fast approximate delivery of fluence maps: the single map case). The resulting large-scale, non-convex optimization problem was solved using a heuristic approach. The single-map approach cannot directly be applied to the full arc case due to the large increase in model size, the issue of allocating delivery times to each of the arc segments, and the fact that the ending leaf positions for one map will be the starting leaf positions for the next map. In this article the method proposed in \\cite{dm1} is extended to solve the full map treatment planning problem. We test ...

  20. An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments

    OpenAIRE

    Rowshanfarzad, Pejman; McGarry, Conor; Barnes, Michael P.; Sabet, Mahsheed; Ebert, Martin A

    2014-01-01

    Background]In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of ensuring the accuracy of linac mechanical performance. Methods The Varian EPID sag, gantry sag, chang...

  1. Increasing the arc efficiency by the removal of arc electromagnetic blowing in electric arc furnaces: I. Effect of electromagnetic blowing and the slag height on the arc efficiency in an electric arc furnace

    Science.gov (United States)

    Makarov, A. N.; Sokolov, A. Yu.; Lugovoi, Yu. A.

    2012-06-01

    The effect of electromagnetic blowing and the slag layer height on the arc efficiency is analytically studied. An arc is blown from under an electrode toward the furnace walls under an electromagnetic force. The arc efficiency of a 100-t high-power electric arc furnace changes from 0.47 to 0.76 when the slag height increases from 0 to 550 mm.

  2. Electrical and thermal finite element modeling of arc faults in photovoltaic bypass diodes.

    Energy Technology Data Exchange (ETDEWEB)

    Bower, Ward Isaac; Quintana, Michael A.; Johnson, Jay

    2012-01-01

    Arc faults in photovoltaic (PV) modules have caused multiple rooftop fires. The arc generates a high-temperature plasma that ignites surrounding materials and subsequently spreads the fire to the building structure. While there are many possible locations in PV systems and PV modules where arcs could initiate, bypass diodes have been suspected of triggering arc faults in some modules. In order to understand the electrical and thermal phenomena associated with these events, a finite element model of a busbar and diode was created. Thermoelectrical simulations found Joule and internal diode heating from normal operation would not normally cause bypass diode or solder failures. However, if corrosion increased the contact resistance in the solder connection between the busbar and the diode leads, enough voltage potentially would be established to arc across micron-scale electrode gaps. Lastly, an analytical arc radiation model based on observed data was employed to predicted polymer ignition times. The model predicted polymer materials in the adjacent area of the diode and junction box ignite in less than 0.1 seconds.

  3. JEMMRLA - Electron Model of a Muon RLA with Multi-pass Arcs

    Energy Technology Data Exchange (ETDEWEB)

    Bogacz, Slawomir Alex; Krafft, Geoffrey A.; Morozov, Vasiliy S.; Roblin, Yves R.

    2013-06-01

    We propose a demonstration experiment for a new concept of a 'dogbone' RLA with multi-pass return arcs -- JEMMRLA (Jlab Electron Model of Muon RLA). Such an RLA with linear-field multi-pass arcs was introduced for rapid acceleration of muons for the next generation of Muon Facilities. It allows for efficient use of expensive RF while the multi-pass arc design based on linear combined-function magnets exhibits a number of advantages over separate-arc or pulsed-arc designs. Here we describe a test of this concept by scaling a GeV scale muon design for electrons. Scaling muon momenta by the muon-to-electron mass ratio leads to a scheme, in which a 4.5 MeV electron beam is injected in the middle of a 3 MeV/pass linac with two double-pass return arcs and is accelerated to 18 MeV in 4.5 passes. All spatial dimensions including the orbit distortion are scaled by a factor of 7.5, which arises from scaling the 200 MHz muon RF to a readily available 1.5 GHz. The hardware requirements are not very demanding making it straightforward to implement. Such an RLA may have applications going beyond muon acceleration: in medical isotope production, radiation cancer therapy and homeland security.

  4. Detecting stellar-wind bubbles through infrared arcs in H ii regions

    Science.gov (United States)

    Mackey, Jonathan; Haworth, Thomas J.; Gvaramadze, Vasilii V.; Mohamed, Shazrene; Langer, Norbert; Harries, Tim J.

    2016-02-01

    Mid-infrared arcs of dust emission are often seen near ionizing stars within H ii regions. A possible explanations for these arcs is that they could show the outer edges of asymmetric stellar wind bubbles. We use two-dimensional, radiation-hydrodynamics simulations of wind bubbles within H ii regions around individual stars to predict the infrared emission properties of the dust within the H ii region. We assume that dust and gas are dynamically well-coupled and that dust properties (composition, size distribution) are the same in the H ii region as outside it, and that the wind bubble contains no dust. We post-process the simulations to make synthetic intensity maps at infrared wavebands using the torus code. We find that the outer edge of a wind bubble emits brightly at 24 μm through starlight absorbed by dust grains and re-radiated thermally in the infrared. This produces a bright arc of emission for slowly moving stars that have asymmetric wind bubbles, even for cases where there is no bow shock or any corresponding feature in tracers of gas emission. The 24 μm intensity decreases exponentially from the arc with increasing distance from the star because the dust temperature decreases with distance. The size distribution and composition of the dust grains has quantitative but not qualitative effects on our results. Despite the simplifications of our model, we find good qualitative agreement with observations of the H ii region RCW 120, and can provide physical explanations for any quantitative differences. Our model produces an infrared arc with the same shape and size as the arc around CD -38°11636 in RCW 120, and with comparable brightness. This suggests that infrared arcs around O stars in H ii regions may be revealing the extent of stellar wind bubbles, although we have not excluded other explanations.

  5. Sensoring Fusion Data from the Optic and Acoustic Emissions of Electric Arcs in the GMAW-S Process for Welding Quality Assessment

    Directory of Open Access Journals (Sweden)

    Eber Huanca Cayo

    2012-05-01

    Full Text Available The present study shows the relationship between welding quality and optical-acoustic emissions from electric arcs, during welding runs, in the GMAW-S process. Bead on plate welding tests was carried out with pre-set parameters chosen from manufacturing standards. During the welding runs interferences were induced on the welding path using paint, grease or gas faults. In each welding run arc voltage, welding current, infrared and acoustic emission values were acquired and parameters such as arc power, acoustic peaks rate and infrared radiation rate computed. Data fusion algorithms were developed by assessing known welding quality parameters from arc emissions. These algorithms have showed better responses when they are based on more than just one sensor. Finally, it was concluded that there is a close relation between arc emissions and quality in welding and it can be measured from arc emissions sensing and data fusion algorithms.

  6. Sensoring fusion data from the optic and acoustic emissions of electric arcs in the GMAW-S process for welding quality assessment.

    Science.gov (United States)

    Alfaro, Sadek Crisóstomo Absi; Cayo, Eber Huanca

    2012-01-01

    The present study shows the relationship between welding quality and optical-acoustic emissions from electric arcs, during welding runs, in the GMAW-S process. Bead on plate welding tests was carried out with pre-set parameters chosen from manufacturing standards. During the welding runs interferences were induced on the welding path using paint, grease or gas faults. In each welding run arc voltage, welding current, infrared and acoustic emission values were acquired and parameters such as arc power, acoustic peaks rate and infrared radiation rate computed. Data fusion algorithms were developed by assessing known welding quality parameters from arc emissions. These algorithms have showed better responses when they are based on more than just one sensor. Finally, it was concluded that there is a close relation between arc emissions and quality in welding and it can be measured from arc emissions sensing and data fusion algorithms.

  7. Risk assessment of metal vapor arcing

    Science.gov (United States)

    Hill, Monika C. (Inventor); Leidecker, Henning W. (Inventor)

    2009-01-01

    A method for assessing metal vapor arcing risk for a component is provided. The method comprises acquiring a current variable value associated with an operation of the component; comparing the current variable value with a threshold value for the variable; evaluating compared variable data to determine the metal vapor arcing risk in the component; and generating a risk assessment status for the component.

  8. Characterization of Micro-arc Oxidized Titanium

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The observation of the sparkling discharges during the micro-arc oxidation process in KOH aqueous electrolyte was achieved. The change of surface morphology was progressively observed and a plausible pore formation mechanism is proposed. Cell proliferation and ALP activity of micro-arc oxidized titanium was evaluated by human body derived osteoblasts and slightly better than those of blasted surface.

  9. The next-generation ARC middleware

    DEFF Research Database (Denmark)

    Appleton, O.; Cameron, D.; Cernak, J.;

    2010-01-01

    The Advanced Resource Connector (ARC) is a light-weight, non-intrusive, simple yet powerful Grid middleware capable of connecting highly heterogeneous computing and storage resources. ARC aims at providing general purpose, flexible, collaborative computing environments suitable for a range of use...

  10. Plasma Arc Augmented CO2 laser welding

    DEFF Research Database (Denmark)

    Bagger, Claus; Andersen, Mikkel; Frederiksen, Niels;

    2001-01-01

    In order to reduce the hardness of laser beam welded 2.13 mm medium strength steel CMn 250, a plasma arc has been used simultaneously with a 2.6 kW CO2 laser source. In a number of systematic laboratory tests, the plasma arc current, plasma gas flow and distance to the laser source were varied wi...

  11. Implementing RapidArc into clinical routine

    DEFF Research Database (Denmark)

    Van Esch, Ann; Huyskens, Dominique P; Behrens, Claus F;

    2011-01-01

    With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) I...

  12. Numerical Study on Arc Plasma Behavior During Arc Commutation Process in Direct Current Circuit Breaker

    Institute of Scientific and Technical Information of China (English)

    杨飞; 马瑞光; 吴翊; 孙昊; 纽春萍; 荣命哲

    2012-01-01

    This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker (DCCB) contact system. A three-dimensional magneto-hydrodynamic (MHD) model of air arc plasma in the contact system of a DCCB is developed, based on commercial software FLUENT. Coupled electromagnetic and gas dynamic interactions are considered as usual, and a thin layer of nonlinear electrical resistance elements is used to represent the voltage drop of plasma sheath and the formation of new arc root. The distributions of pressure, temperature, gas flow and current density of arc plasma in arc region are calculated. The simulation results indicate that the pressure distribution related to the contact system has a strong effect on the arc commutation process, arising from the change of electrical conductivity in the arc root region. In DCCB contact system, the pressure of arc root region will be concentrated and higher if the space above the moving contact is enclosed, which is not good for arc root commutation. However, when the region is opened, the pressure distribution would be lower and more evenly, which is favorable for the arc root commutation.

  13. Sensor Control of Robot Arc Welding

    Science.gov (United States)

    Sias, F. R., Jr.

    1983-01-01

    The potential for using computer vision as sensory feedback for robot gas-tungsten arc welding is investigated. The basic parameters that must be controlled while directing the movement of an arc welding torch are defined. The actions of a human welder are examined to aid in determining the sensory information that would permit a robot to make reproducible high strength welds. Special constraints imposed by both robot hardware and software are considered. Several sensory modalities that would potentially improve weld quality are examined. Special emphasis is directed to the use of computer vision for controlling gas-tungsten arc welding. Vendors of available automated seam tracking arc welding systems and of computer vision systems are surveyed. An assessment is made of the state of the art and the problems that must be solved in order to apply computer vision to robot controlled arc welding on the Space Shuttle Main Engine.

  14. Arc flash hazard analysis and mitigation

    CERN Document Server

    Das, J C

    2012-01-01

    "All the aspects of arc flash hazard calculations and their mitigation have been covered. Knowledge of electrical power systems up to undergraduate level is assumed. The calculations of short-circuits, protective relaying and varied electrical system configurations in industrial power systems are addressed. Protection systems address differential relays, arc flash sensing relays, protective relaying coordination, current transformer operation and saturation and applications to major electrical equipments from the arc flash considerations. Current technologies and strategies for arc flash mitigation have been covered. A new algorithm for the calculation of arc flash hazard accounting for the decaying nature of the short-circuit currents is included. There are many practical examples and study cases. Review questions and references follow each chapter"--

  15. Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy

    Science.gov (United States)

    Pommer, Tobias; Falk, Marianne; Poulsen, Per R.; Keall, Paul J.; O’Brien, Ricky T.; Petersen, Peter Meidahl; Rosenschöld, Per Munck af

    2013-01-01

    This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode arrays was used for dosimetry. A motion platform reproduced six patient-derived prostate motion traces, with the average displacement ranging from 1.0 to 8.9 mm during the first 75 seconds. A research DMLC tracking system was used for real-time motion compensation with optical monitoring for position input. The gamma index was used for evaluation, with measurements with a static phantom or the planned dose as reference, using 2% and 2 mm gamma criteria. The average pass rate with DMLC tracking was 99.9% (range 98.7–100%, measurement as reference), whereas the pass rate for untracked deliveries decreased distinctly as the average displacement increased, with an average pass rate of 61.3% (range 32.7–99.3%). Dose-volume histograms showed that DMLC tracking maintained the planned dose distributions in the presence of motion whereas traces with > 3 mm average displacement caused clear plan degradation for untracked deliveries. The dose to the rectum and bladder had an evident dependence on the motion direction and amplitude for untracked deliveries, and the dose to the rectum was slightly increased for IPL boosted plans compared to conventional plans for anterior motion with large amplitude. In conclusion, optimization using a leaf

  16. Computer simulation to arc spraying

    Institute of Scientific and Technical Information of China (English)

    梁志芳; 李午申; 王迎娜

    2004-01-01

    The arc spraying process is divided into two stages: the first stage is atomization-spraying stream (ASS) and the second one is spraying deposition (SD). Then study status is described of both stages' physical model and corresponding controlling-equation. Based on the analysis of study status, the conclusion as follows is got. The heat and mass transfer models with two or three dimensions in ASS stage should be established to far deeply analyses the dynamical and thermal behavior of the overheat droplet. The statistics law of overheated droplets should be further studied by connecting simulation with experiments. More proper validation experiments should be designed for flattening simulation to modify the models in SD stage.

  17. ATLAS DDM integration in ARC

    DEFF Research Database (Denmark)

    Behrmann, Gerd; Cameron, David; Ellert, Mattias;

    The Nordic Data Grid Facility (NDGF) consists of Grid resources running ARC middleware in Scandinavia and other countries. These resources serve many virtual organisations and contribute a large fraction of total worldwide resources for the ATLAS experiment, whose data is distributed and managed...... by the DQ2 software. Managing ATLAS data within NDGF and between NDGF and other Grids used by ATLAS (the LHC Computing Grid and the Open Science Grid) presents a unique challenge for several reasons. Firstly, the entry point for data, the Tier 1 centre, is physically distributed among heterogeneous...... resources in several countries and yet must present a single access point for all data stored within the centre. The middleware framework used in NDGF differs significantly from other Grids, specifically in the way that all data movement and registration is performed by services outside the worker node...

  18. ATLAS DDM integration in ARC

    DEFF Research Database (Denmark)

    Behrmann, Gerd; Cameron, David; Ellert, Mattias;

    2008-01-01

    The Nordic Data Grid Facility (NDGF) consists of Grid resources running ARC middleware in Denmark, Finland, Norway and Sweden. These resources serve many virtual organisations and contribute a large fraction of total worldwide resources for the ATLAS experiment, whose data is distributed...... and managed by the DQ2 software. Managing ATLAS data within NDGF and between NDGF and other Grids used by ATLAS (the Enabling Grids for E-sciencE Grid and the Open Science Grid) presents a unique challenge for several reasons. Firstly, the entry point for data, the Tier 1 centre, is physically distributed...... among heterogeneous resources in several countries and yet must present a single access point for all data stored within the centre. The middleware framework used in NDGF differs significantly from other Grids, specifically in the way that all data movement and registration is performed by services...

  19. Plasma arc welding weld imaging

    Science.gov (United States)

    Rybicki, Daniel J. (Inventor); Mcgee, William F. (Inventor)

    1994-01-01

    A welding torch for plasma arc welding apparatus has a transparent shield cup disposed about the constricting nozzle, the cup including a small outwardly extending polished lip. A guide tube extends externally of the torch and has a free end adjacent to the lip. First and second optical fiber bundle assemblies are supported within the guide tube. Light from a strobe light is transmitted along one of the assemblies to the free end and through the lip onto the weld site. A lens is positioned in the guide tube adjacent to the second assembly and focuses images of the weld site onto the end of the fiber bundle of the second assembly and these images are transmitted along the second assembly to a video camera so that the weld site may be viewed continuously for monitoring the welding process.

  20. INTERPOLATION WITH RESTRICTED ARC LENGTH

    Institute of Scientific and Technical Information of China (English)

    Petar Petrov

    2003-01-01

    For given data (ti,yi), I= 0,1,…,n,0 = t0 <t1 <…<tn = 1we study constrained interpolation problem of Favard type inf{‖f"‖∞|f∈W2∞[0,1],f(ti)=yi,i=0,…,n,l(f;[0,1])≤l0}, wherel(f";[0,1])=∫1 0 / 1+f'2(x)dx is the arc length off in [0,1]. We prove the existence of a solution f* of the above problem, that is a quadratic spline with a second derivative f"* , which coincides with one of the constants - ‖f"*‖∞,0,‖f"*‖∞ between every two consecutive knots. Thus, we extend a result ofKarlin concerning Favard problem, to the case of restricted length interpolation.

  1. Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique

    International Nuclear Information System (INIS)

    Frequently, three-dimensional (3D) conformal beams are used in lung cancer stereotactic body radiotherapy (SBRT). Recently, volumetric modulated arc therapy (VMAT) was introduced as a new treatment modality. VMAT techniques shorten delivery time, reducing the possibility of intrafraction target motion. However dose distributions can be quite different from standard 3D therapy. This study quantifies those differences, with focus on VMAT plans using unflattened photon beams. A total of 15 lung cancer patients previously treated with 3D or VMAT SBRT were randomly selected. For each patient, non-coplanar 3D, coplanar and non-coplanar VMAT and flattening filter free VMAT (FFF-VMAT) plans were generated to meet the same objectives with 50 Gy covering 95% of the PTV. Two dynamic arcs were used in each VMAT plan. The couch was set at ± 5° to the 0° straight position for the two non-coplanar arcs. Pinnacle version 9.0 (Philips Radiation Oncology, Fitchburg WI) treatment planning system with VMAT capabilities was used. We analyzed the conformity index (CI), which is the ratio of the total volume receiving at least the prescription dose to the target volume receiving at least the prescription dose; the conformity number (CN) which is the ratio of the target coverage to CI; and the gradient index (GI) which is the ratio of the volume of 50% of the prescription isodose to the volume of the prescription isodose; as well as the V20, V5, and mean lung dose (MLD). Paired non-parametric analysis of variance tests with post-tests were performed to examine the statistical significance of the differences of the dosimetric indices. Dosimetric indices CI, CN and MLD all show statistically significant improvement for all studied VMAT techniques compared with 3D plans (p < 0.05). V5 and V20 show statistically significant improvement for the FFF-VMAT plans compared with 3D (p < 0.001). GI is improved for the FFF-VMAT and the non-coplanar VMAT plans (p < 0.01 and p < 0.05 respectively

  2. Analysis of arc emission spectra of stainless steel electric arc furnace slag affected by fluctuating arc voltage.

    Science.gov (United States)

    Aula, Matti; Mäkinen, Ari; Fabritius, Timo

    2014-01-01

    Control of chromium oxidation in the electric arc furnace (EAF) is a significant problem in stainless steel production due to variations of the chemical compositions in the EAF charge. One potential method to control chromium oxidation is to analyze the emission spectrum of the electric arc in order to find indicators of rising chromium content in slag. The purpose of this study was to determine if slag composition can be gained by utilizing electric arc emission spectra in the laboratory environment, despite electric arc voltage fluctuations and varying slag composition. The purpose of inducing voltage fluctuation was to simulate changes in the industrial EAF process. The slag samples were obtained from Outokumpu Stainless Oy Tornio Works, and three different arc currents were used. The correlation analysis showed that the emission spectra offer numerous peak ratios with high correlations to the X-ray fluorescence-measured slag CrO(x)/FeO(x) and MnO/SiO2 ratios. These ratios are useful in determining if the reduction agents have been depleted in the EAF. The results suggest that analysis of laboratory-scale electric arc emission spectra is suitable for indicating the high CrO(x) or MnO content of the slag despite the arc fluctuations. Reliable analysis of other slag components was not successful.

  3. Measurement of cathode surface temperature using the method of CCD imaging in arc discharge

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    A two-wavelength pyrometry device using ordinary array CCD (charge coupled device) to collect the radiation data in the horizontal and vertical directions has been developed for measuring the cathode surface temperature during the arc discharge. Analyses of experimental results show that the device can make the measurement of the cathode surface temperature feasible. The cathode surface temperatures measured are lower than the melting point of tungsten (3653 K), and the arc current, cathode diameter, and the cathode length are the main influencing factors of the cathode surface temperature.

  4. Investigation of Metal Puff Z pinch Based on Multichannel Vacuum Arcs

    Science.gov (United States)

    Rousskikh, A. G.; Oreshkin, V. I.; Zhigalin, A. S.; Chaikovsky, S. A.; Baksht, R. B.; Mitrofanov, K. N.

    2015-11-01

    The performance of a metal double puff Z-pinch system has been studied experimentally. In this type of system, the outer and inner cylindrical shells were produced by ten plasma guns. Each gun initiates a vacuum arc operating between aluminum electrodes. The net current of the guns was 80 kA. The arc-produced plasma shells were compressed by using a 450-kA, 450-ns driver, and as a result, a plasma column 0.2 cm in diameter was formed. The power of the Al K-line radiation emitted by the plasma for 7 ns was 800 MW/cm.

  5. Synchrotron radiation and biomedical imaging

    International Nuclear Information System (INIS)

    In this lecture we describe the characteristics of Synchrotron radiation as a source of X rays. We discuss the properties of SR arc sources, wigglers, undulators and the use of backscattering of laser light. Applications to angiography, X ray microscopy and tomography are reviewed. 16 refs., 23 figs

  6. Characteristics of acoustic-controlled arc in ultrasonic wave-assisted arc%超声复合电弧声调控特性研究

    Institute of Scientific and Technical Information of China (English)

    谢伟峰; 范成磊; 杨春利; 林三宝; 张玉岐

    2015-01-01

    As a new welding method, ultrasound has been successfully introduced into the pool during ultrasonic wave-assisted arc welding process. However, the interaction mechanism between the ultrasound and the arc plasma is not clear, thus preventing the new technique from engineering applications. In this paper, the characteristic of arc regulation by external ultrasonic field is investigated based on the experimental data and the corresponding theory. In order to figure out the characteristics of arc, the arc images obtained by high-speed camera are processed. Compared with the conventional welding arc, ultrasonic wave-assisted arc is more contracted and becomes brighter, the high-temperature region in an arc column greatly expands, and there are internal particle agglomerations shaking up and down at a constant frequency. The arc shape varies with ultrasound excitation current and the height of ultrasonic radiator. In the vicinity of the resonance point, the straight-degree of the arc is the strongest and the ripple frequency is also the largest. Results show that the purpose of using external ultrasound field to regulate the thermal plasma has basically achieved. Analyzing the acoustic pressure wave equation for the neutral component shows that the spatial distribution of acoustic wave can be generated in the arc and its intensity is proportional to the local amplitude of acoustic waves. Acoustic pressure field can be calculated based on the dependence of the electron temperature and density on time and space. In addition to the action of acoustic field within the arc, the arc plasma is also controlled by the acoustic field structure. A two-cylinder model incorporating boundary element method is developed, establishing a relationship between the binding capability and the geometric parameters of an ultrasonic radiator with reference to wavelength. This model is successful in predicting resonant modes of the acoustic field and explaining the influences of the ultrasonic

  7. Intrafractional 3D localization using kilovoltage digital tomosynthesis for sliding-window intensity modulated radiation therapy.

    Science.gov (United States)

    Zhang, Pengpeng; Hunt, Margie; Pham, Hai; Tang, Grace; Mageras, Gig

    2015-09-01

    To implement novel imaging sequences integrated into intensity modulated radiation therapy (IMRT) and determine 3D positions for intrafractional patient motion monitoring and management.In one method, we converted a static gantry IMRT beam into a series of arcs in which dose index and multileaf collimator positions for all control points were unchanged, but gantry angles were modified to oscillate ± 3° around the original angle. Kilovoltage (kV) projections were acquired continuously throughout delivery and reconstructed to provide a series of 6° arc digital tomosynthesis (DTS) images which served to evaluate the in-plane positions of embedded-fiducials/vertebral-body. To obtain out-of-plane positions via triangulation, a 20° gantry rotation with beam hold-off was inserted during delivery to produce a pair of 6° DTS images separated by 14°. In a second method, the gantry remained stationary, but both kV source and detector moved over a 15° longitudinal arc using pitch and translational adjustment of the robotic arms. Evaluation of localization accuracy in an anthropomorphic Rando phantom during simulated intrafractional motion used programmed couch translations from customized scripts. Purpose-built software was used to reconstruct DTS images, register them to reference template images and calculate 3D fiducial positions.No significant dose difference (<0.5%) was found between the original and converted IMRT beams. For a typical hypofractionated spine treatment, 200 single DTS (6° arc) and 10 paired DTS (20° arc) images were acquired for each IMRT beam, providing in-plane and out-of-plane monitoring every 1.6 and 34.5 s, respectively. Mean ± standard deviation error in predicted position was -0.3 ± 0.2 mm, -0.1 ± 0.1 mm in-plane, and 0.2 ± 0.4 mm out-of-plane with rotational gantry, 0.8 ± 0.1 mm, -0.7 ± 0.3 mm in-plane and 1.1 ± 0.1 mm out-of-plane with translational source/detector.Acquiring 3D fiducial positions from kV-DTS during fixed gantry

  8. Acoustic characteristics of electric arc furnaces

    Science.gov (United States)

    Cherednichenko, V. S.; Bikeev, R. A.; Cherednichenko, A. V.; Ognev, A. M.

    2016-06-01

    A mathematical model is constructed to describe the appearance and development of the noise characteristics of superpower electric arc furnaces. The noise formation is shown to be related to the pulsation of the axial plasma flows in arc discharges because of the electrodynamic pressure oscillations caused by the interaction of the self-magnetic field with the current passing in an arc. The pressure in the arc axis changes at a frequency of 100 Hz at the maximum operating pressure of 66 kPa for an arc current of 80 kA. The main ac arc sound frequencies are multiples of 100 Hz, which is supported in the practice of operation of electric arc furnaces. The sound intensity in the furnace laboratory reaches 160 dB and is decreased to 115-120 dB in the working furnace area due to shielding by the furnace jacket, the molten metal, and the molten slag. The appropriateness of increasing the hermetic sealing of electric furnaces and creating furnaces operating at low currents and high transformer voltages is corroborated.

  9. Reconstruction of Late Cretaceous Magmatic Arcs in the Northern Andes: Single Versus Multiple Arc Systems

    Science.gov (United States)

    Cardona, A.; Jaramillo, J. S.; Leon, S.; Hincapie, S.; Mejia, D.; Patino, A. M.; Vanegas, J.; Zapata, S.; Valencia, V.; Jimenez, G.; Monsalve, G.

    2014-12-01

    Although magmatic rocks are major tracers of the geological evolution of convergent margins, pre-collisional events such as subduction erosion, collisional thrusting or late collisional strike slip segmentation may difficult the recognizing of multiple arc systems and therefore the existence of paleogeographic scenarios with multiple subduction systems. New field, U-Pb geochronology and whole rock geochemistry constraints from the northwestern segment of the Central Cordillera in the states of Antioquia and Caldas (Colombia) are used to understand the nature of the Late Cretaceous arc magmatism and evaluate the existence of single or multiple Pacific and Caribbean arc systems in the growth of the Northwestern Andes. The new results integrated with additional field and published information is used to suggest the existence of at least three different magmatic arcs. (1) An Eastern Continental arc built within a well defined Permian to Triassic continental crust that record a protracted 90-70 Ma magmatic evolution, (2) a 90-80 arc formed within attenuated continental crust and associated oceanic crust, (3) 90-88 Ma arc formed over a Late Cretaceous plateau crust. The eastern arcs were formed as part of double eastern vergent subduction system, where the most outboard arc represent a fringing arc formed over detached fragments of continental crust, whereas the easternmost continental arc growth by the closure an subduction of and older and broad Triassic to Early Jurassic back-arc ocean. Its closure also end up in ophiolite emplacement. The third allochtonous oceanic arc was formed over the Caribbean plateau crust and was accreted to the continental margin in the Late Cretaceous. Ongoing paleomagnetic, deformational, gravimetric and basin analysis will be integrate to test this model and understand the complex Late Cretaceous tectonic evolution of the Northern Andes.

  10. Arcing and rf signal generation during target irradiation by a high-energy, pulsed neutral particle beam

    International Nuclear Information System (INIS)

    We present a theory describing the dynamics of arc discharges in bulk dielectric materials on board space-based vehicles. Such ''punch-through'' arcs can occur in target satellites irradiated by high-energy (250 MeV), pulsed (100 mA x 10 ms) neutral particle beams. We treat the arc as a capacitively limited avalanche current in the target dielectric material, and we find expressions for the arc duration, charge transport, currents, and discharge energy. These quantities are adjusted to be consistent with known scaling laws for the area of charge depleted by the arc. After a brief account of the statistical distribution of voltages at which the arc starts and stops, we calculate the signal strength and frequency spectrum of the electromagnetic radiation broadcast by the arc. We find that arcs from thick (/similar to/1 cm) targets can generate rf signals detectable up to 1000 km from the target, bu a radio receiver operating at frequency 80 MHz, bandwidth 100 kHz, and detection threshold -105 dBm. These thick-target arc signals are 10 to 20 dB above ambient noise at the receiver, and they provide target hit assessment if the signal spectrum can be sampled at several frequencies in the nominal range 30-200 MHz. Thin-target (/similar to/1 mm) arc signals are much weaker, but when they are detecable in conjunction with thick-target signals, target discrimination is possible by comparing the signal frequency spectra. 24 refs., 12 figs

  11. Comparing four volumetric modulated arc therapy beam arrangements for the treatment of early-stage prostate cancer

    International Nuclear Information System (INIS)

    This study compared four different volumetric modulated arc therapy (VMAT) beam arrangements for the treatment of early-stage prostate cancer examining plan quality and the impact on a radiotherapy department's resources. Twenty prostate cases were retrospectively planned using four VMAT beam arrangements (1) a partial arc (PA), (2) one arc (1A), (3) one arc plus a partial arc (1A + PA) and (4) two arcs (2A). The quality of the dose distributions generated were compared by examining the overall plan quality, the homogeneity and conformity to the planning target volume (PTV), the number of monitor units and the dose delivered to the organs at risk. Departmental resources were considered by recording the planning time and beam delivery time. Each technique produced a plan of similar quality that was considered adequate for treatment; though some differences were noted. The 1A, 1A + PA and 2A plans demonstrated a better conformity to the PTV which correlated to improved sparing of the rectum in the 60–70 Gy range for the 1A + PA and 2A techniques. The time needed to generate the plans was different for each technique ranging from 13.1 min for 1A + PA to 17.8 min for 1A. The PA beam delivery time was fastest with a mean time of 0.9 min. Beam-on times then increased with an increase in the number of arcs up to an average of 2.2 min for the 2A technique. Which VMAT technique is best suited for clinical implementation for the treatment of prostate cancer may be dictated by the individual patient and the availability of departmental resources

  12. Modeling Multi-Arc Spraying Systems

    Science.gov (United States)

    Bobzin, K.; Öte, M.

    2016-06-01

    The use of plasma as energy source in thermal spraying enables among others the processing of feed stock materials with very high melting temperatures as coating materials. New generation multi-arc plasma spraying systems are widely spread and promise several advantages in comparison to the conventional single-arc systems. Numerical modeling of multi-arc plasma spraying offers the possibility to increase the understanding about this process. This study focuses on the numerical modeling of three-cathode spraying systems, introducing the recent activities in this field and discussing the numerical aspects which influence the prediction power of the models.

  13. Formation of the G-ring arc

    Science.gov (United States)

    Araujo, N. C. S.; Vieira Neto, E.; Foryta, D. W.

    2016-09-01

    Since 2004, the images obtained by the Cassini spacecraft's on-board cameras have revealed the existence of several small satellites in the Saturn system. Some of these small satellites are embedded in arcs of particles. While these satellites and their arcs are known to be in corotation resonances with Mimas, their origin remains unknown. This work investigates one possible process for capturing bodies into a corotation resonance, which involves increasing the eccentricity of a perturbing body. Therefore, through numerical simulations and analytical studies, we show a scenario in which the excitation of Mimas's eccentricity could capture particles in a corotation resonance. This is a possible explanation for the origin of the arcs.

  14. Formation of the G-ring arc

    CERN Document Server

    Araujo, N C S; Foryta, D W

    2016-01-01

    Since 2004, the images obtained by Cassini spacecraft's on-board cameras have revealed the existence of several small satellites in the Saturn system. Some of these small satellites are embedded in arcs of particles. While these satellites and their arcs are known to be in corotation resonances with Mimas, their origin remains unknown. This work investigates one possible process for capturing bodies into a corotation resonance, which involves raising the eccentricity of a perturbing body. Therefore, through numerical simulations and analytical studies, we show a scenario that the excitation of Mimas' eccentricity could capture particles in a corotation resonance and given a possible explanation for the origin for the arcs.

  15. Arc saw and its application to decommissioning

    International Nuclear Information System (INIS)

    The arc saw is a toothless, circular saw that cuts by arc erosion. A model was built to study the arc saw's usefulness in cutting up radioactively contaminated metal scrap. It was chosen because it cuts with very little contact to the work piece and because cutting is not affected by material hardness. After installation of several improvements it was found it could cut almost any combination of metals and that clamping or fixturing requirements were minimum. Cutting proceeds rapidly and efficiently. 10 figures

  16. Fractionated stereotactic radiotherapy of benign skull-base tumors: a dosimetric comparison of volumetric modulated arc therapy with Rapidarc® versus non-coplanar dynamic arcs

    OpenAIRE

    Martin, Fanny; Magnier, Florian; Berger, Lucie; Miroir, Jessica; Chautard, Emmanuel; Verrelle, Pierre; Lapeyre, Michel; Biau, Julian

    2016-01-01

    Background Benign tumors of the skull base are a challenge when delivering radiotherapy. An appropriate choice of radiation technique may significantly improve the patient’s outcomes. Our study aimed to compare the dosimetric results of fractionated stereotactic radiotherapy between non-coplanar dynamic arcs and coplanar volumetric modulated arctherapy (Rapidarc®). Methods Thirteen patients treated with Novalis TX® were analysed: six vestibular schwannomas, four pituitary adenomas and three m...

  17. Linear volcanic segments in the Sunda Arc, Indonesia: Implications for arc lithosphere control upon volcano distribution

    Science.gov (United States)

    Macpherson, C. G.; Pacey, A.; McCaffrey, K. J.

    2012-12-01

    The overall curvature of many subduction zones is immediately apparent and the term island arc betrays the common assumption that subduction zone magmatism occurs in curved zones. This assumption can be expressed by approximating island arcs as segments of small circles on the surface of a sphere. Such treatments predict that the location of arc volcanoes is related to their vertical separation from the slab (in fact, the depth to seismicity in the slab) and require that the primary control on the locus of magmatism lies either within the subducted slab or the mantle wedge that separates the subducted and overriding lithospheric plates. The concept of curved arcs ignores longstanding observations that magmatism in many subduction systems occurs as segments of linearly arranged volcanic centres. Further evidence for this distribution comes from the close relationship between magmatism and large scale, arc-parallel fabrics in some arcs. Similarly, exposures of deep arc crust or mantle often reveal elongation of magmatic intrusions sub-parallel to the inferred trend of the arc. The Sunda Arc forms the Indonesian islands from Sumatra to Alor and provides an important test for models of volcano distribution for several reasons. First, Sunda has hosted abundant historic volcanic activity. Second, with the notable exception of Krakatau, every volcano in the arc is subaerial from base to cone and, therefore, can be readily identified where there is a suitable extent of local mapping that can be used to ground-truth satellite imagery. Third, there are significant changes in the stress regime along the length of the arc, allowing the influence of the upper plate to be evaluated by comparison of different arc segments. Finally, much of the Sunda Arc has proved difficult to accommodate in models that try to relate volcano distribution to the depth to the subducted slab. We apply an objective line-fitting protocol; the Hough Transform, to explore the distribution of volcanoes

  18. Numerical predictions of railgun performance including the effects of ablation and arc drag

    Science.gov (United States)

    Schnurr, N. M.; Kerrisk, J. F.; Parker, J. V.

    Thermal radiation from plasma armatures in railguns may cause vaporization and partial ionization of the rail and insulator materials. This causes an increase in mass of the arc, which has an adverse effect on projectile velocity. Viscous drag on the arc also has a deleterious effect, particularly at high velocities. These loss mechanisms are modeled in the Los Alamos Railgun Estimator code. Simulations were performed and numerical results were compared with experimental data for a wide range of tests performed at the Los Alamos and Lawrence Livermore National Laboratories, the Ling Temco Vought Aerospace and Defense Company, and the Center for Electromechanics at the University of Texas at Austin. The effects of ablation and arc drag on railgun performance are discussed. Parametric studies illustrate the effects of some design parameters on projectile velocity and launcher efficiency. Some strategies for reducing the effects of ablation are proposed.

  19. Dynamics of vaporization and dissociation during transient surface heating, with application to vacuum arcs

    International Nuclear Information System (INIS)

    This report describes a model of vaporization and dissociation occurring as a result of intense heating over a localized area of a material surface. The balance of heat between the input power and losses due to vaporization, as well as radiation and conduction in the material, are considered. The model includes the effect of binary mass diffusion and changes of surface stoichiometry for multiple component materials. Effects of vapor recondensation are included. The model is then applied to the description of spot heating on a vacuum arc anode through the use of a simple power feedback model. Comparison of surface temperature measurements to model predictions are used to parametrically describe the arc behavior. Finally, extensive parametric analyses showing the effect of material property variations on the arc behavior are described

  20. Poster — Thur Eve — 39: Feasibility of Commissioning HybridArc with the Delta 4 two plane diode phantom: comparisons with Gafchromic Film

    Energy Technology Data Exchange (ETDEWEB)

    Bojechko, C. [University of Calgary, Department of Physics and Astronomy, Tom Baker Cancer Center, Calgary AB (Canada); Ploquin, N. [University of Calgary, Department of Physics and Astronomy, Tom Baker Cancer Center, Calgary AB (Canada); University of Calgary, Department of Oncology, Tom Baker Cancer Center, Calgary AB (Canada); Hudson, A. [University of Calgary, Department of Oncology, Tom Baker Cancer Center, Calgary AB (Canada); Sayous, Y. [Université Paul Sabotier Toulouse (France)

    2014-08-15

    HybridArc is a relatively novel radiation therapy technique which combines optimized dynamic conformai arcs (DCA) and intensity modulated radiation therapy (IMRT). HybridArc has possible dosimetry and efficiency advantages over stand alone DCA and IMRT treatments and can be readily implemented on any linac capable of DCA and IMRT, giving strong motivation to commission the modality. The Delta4 phantom (Scandidos, Uppsala, Sweden) has been used for IMRT and VMAT clinical dosimetric verification making it a candidate for HybridArc commissioning. However the HybridArc modality makes use of several non co-planar arcs which creates setup issues due to the geometry of the Delta4, resulting in possible phantom gantry collisions for plans with non-zero couch angles. An analysis was done determining the feasibility of using the Delta4 fixed at 0° couch angle compared with results obtained using Gafchromic ETB2 film (Ashland, Covington Kentucky) in an anthropomorphic phantom at the planned couch angles. A gamma index analysis of the measured and planned dose distributions was done using Delta4 and DoseLab Pro (Mobius Medical Systems, Houston Texas) software. For both arc and IMRT sub-fields there is reasonable correlation between the gamma index found from the Delta4 and Gafchromic film. All results show the feasibility of using the Delta4 for HybridArc commissioning.

  1. eDelivery

    Data.gov (United States)

    US Agency for International Development — eDelivery provides the electronic packaging and delivery of closed and complete OPM investigation files to government agencies, including USAID, in a secure manner....

  2. NEW DRUG DELIVERY SYSTEM

    OpenAIRE

    Sarkar Biresh K; Jain Devananda; Banerjee Angshu

    2011-01-01

    Incorporating an existing medicine into a new drug delivery system can significantly improve its performance in terms of efficacy, safety, and improved patient compliance. The need for delivering drugs to patients efficiently and with fewer side effects has prompted pharmaceutical companies to engage in the development of new drug delivery systems. Today, drug delivery companies are engaged in the development of multiple platform technologies for controlled release, delivery of large molecule...

  3. Prostate treatments, 1MRT o RapidArc; Tratamiento de prostata, IMART o RapidArc?

    Energy Technology Data Exchange (ETDEWEB)

    Castro novais, J.; Ruiz Maqueda, S.; Pardo Perez, E.; Molina Lopez, M. Y.; Cerro Penalver, E.

    2015-07-01

    Techniques that modulate the dose (as IMRT or RapidArcTM) improve dose homogeneity within the target volume decreasing the dose in healthy organs. The aim of this work is to study the dosimetric differences in prostate radiotherapy treatments with IMRT and RapidArcTM. The results of the 109 patients studied show that plans to RapidArcTM have better coverage, compliance and dose gradient outside the target volume. (Author)

  4. Stretched arc discharge in produced water.

    Science.gov (United States)

    Cho, Y I; Wright, K C; Kim, H S; Cho, D J; Rabinovich, A; Fridman, A

    2015-01-01

    The objective of the present study was to investigate the feasibility of stretching an arc discharge in produced water to increase the volume of produced water treated by plasma. Produced water is the wastewater generated by hydraulic fracturing of shale during the production phase in shale-oil or shale-gas exploration. The electric conductivity of produced water is in the range of 50-200 mS/cm, which provides both a challenge and opportunity for the application of plasmas. Stretching of an arc discharge in produced water was accomplished using a ground electrode and two high-voltage electrodes: one positioned close to the ground electrode and the other positioned farther away from the ground. The benefit of stretching the arc is that the contact between the arc and water is significantly increased, resulting in more efficient plasma treatment in both performance and energy cost. PMID:25638080

  5. Observation of gliding arc surface treatment

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Zhu, Jiajian; Ehn, A.;

    2015-01-01

    . Water contact angle measurements indicate that the treatment uniformity improves significantly when the AC gliding arc is tilted to the polymer surface. Thickness reduction of the gas boundary layer, explaining the improvement of surface treatment, by the ultrasonic irradiation was directly observed for......An alternating current (AC) gliding arc can be conveniently operated at atmospheric pressure and efficiently elongated into the ambient air by an air flow and thus is useful for surface modification. A high speed camera was used to capture dynamics of the AC gliding arc in the presence of polymer...... surfaces. A gap was observed between the polymer surface and the luminous region of the plasma column, indicating the existence of a gas boundary layer. The thickness of the gas boundary layer is smaller at higher gas flow-rates or with ultrasonic irradiation to the AC gliding arc and the polymer surface...

  6. Sitka, Alaska 1 arc-second DEM

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Sitka, Alaska Elevation Grid provides bathymetric data in ASCII raster format of 1 arc-second resolution in geographic coordinates. This grid is strictly for...

  7. Seward, Alaska 1 arc-second DEM

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 1 arc-second Seward Alaska Elevation Grid provides bathymetric data in ASCII raster format of .89-second resolution in geographic coordinates. This grid is...

  8. 49 CFR 195.226 - Welding: Arc burns.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding: Arc burns. 195.226 Section 195.226 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Construction § 195.226 Welding: Arc burns. (a) Each arc burn must be repaired. (b) An arc burn...

  9. Arc distribution during the vacuum arc remelting of Ti-6Al-4V

    Energy Technology Data Exchange (ETDEWEB)

    Woodside, Charles Rigel [U.S. DOE; King, Paul E. [U.S. DOE; Nordlund, Chris [ATI Albany Operations

    2013-01-01

    Currently, the temporal distribution of electric arcs across the ingot during vacuum arc remelting (VAR) is not a known or monitored process parameter. Previous studies indicate that the distribution of arcs can be neither diffuse nor axisymmetric about the center of the furnace. Correct accounting for the heat flux, electric current flux, and mass flux into the ingot is critical to achieving realistic solidification models of the VAR process. The National Energy Technology Laboratory has developed an arc position measurement system capable of locating arcs and determining the arc distribution within an industrial VAR furnace. The system is based on noninvasive magnetic field measurements and a VAR specific form of the Biot–Savart law. The system was installed on a coaxial industrial VAR furnace at ATI Albany Operations in Albany, OR. This article reports on the different arc distributions observed during production of Ti-6Al-4V. It is shown that several characteristic arc distribution modes can develop. This behavior is not apparent in the existing signals used to control the furnace, indicating the measurement system is providing new information. It is also shown that the different arc distribution modes observed may impact local solidification times, particularly at the side wall.

  10. Heat flow in the Lesser Antilles island arc and adjacent back arc Grenada basin

    OpenAIRE

    Manga, Michael; Hornbach, Matthew J.; Friant, Anne Le; Ishizuka, Osamu; Stroncik, Nicole; Adachi, Tatsuya; Aljahdali, Mohammed; Boudon, Georges; Breitkreuz, Christoph; Fraass, Andrew; Fujinawa, Akihiko; Hatfield, Robert; Jutzeler, Martin; Kataoka, Kyoko; Lafuerza, Sara

    2012-01-01

    Using temperature gradients measured in 10 holes at 6 sites, we generate the first high fidelity heat flow measurements from Integrated Ocean Drilling Program drill holes across the northern and central Lesser Antilles arc and back arc Grenada basin. The implied heat flow, after correcting for bathymetry and sedimentation effects, ranges from about 0.1 W/m2 on the crest of the arc, midway between the volcanic islands of Montserrat and Guadeloupe, to 15 km from the crest in the back arc direct...

  11. Spectral characteristics of arc plasma during laser-arc double-sided welding for aluminum alloy

    Institute of Scientific and Technical Information of China (English)

    Kezhao Zhang; Zhenglong Lei; Xianglong Wang; Yanbin Chen; Yaobang Zhao

    2015-01-01

    In laser-arc double-sided welding,the spectral characteristics of the arc plasma are calculated and analyzed by spectroscopic diagnosis.The results show that,compared with conventional tungsten inert gas (TIG) welding,the introduction of a laser changes the physical characteristics of the arc plasma regardless of whether laser plasma penetration takes place,and that the influence of the laser mainly affects the near-anode region of the arc.When the laser power is relatively low,the arc column tends to compress,and the arc spectral characteristics show no significant difference.When the arc root constricts,compared with pure TIG arc,the electron density increases by ~2.7 times and the electron temperature decreases by ~3000 K.When the arc column expands,the intensities of spectral lines of both the metal and Ar atoms are the strongest.But it is also observed that the electron density reduces,whereas there is no obvious decrease of electron temperature.

  12. Overtwisted open books from sobering arcs

    OpenAIRE

    Goodman, Noah

    2004-01-01

    We study open books on three manifolds which are compatible with an overtwisted contact structure. We show that the existence of certain arcs, called sobering arcs, is a sufficient condition for an open book to be overtwisted, and is necessary up to stabilization by positive Hopf-bands. Using these techniques we prove that some open books arising as the boundary of symplectic configurations are overtwisted, answering a question of Gay in Algebr. Geom. Topol. 3 (2003) 569--586.

  13. Hybrid Laser-Arc Welding Tanks Steels

    Science.gov (United States)

    Turichin, G.; Tsibulskiy, I.; Kuznetsov, M.; Akhmetov, A.; Klimova-Korsmik, O.

    2016-04-01

    The results investigate hybrid laser-arc welding of high strength steels using design responsible metallic construction and the highest strength body of vehicles. Welds from modern high strength steels grade Hardox 400, Hardox 450, Armox 600T and AB were created. High power fiber laser LS-15 with output 15 kW and arc rectifier VDU - 1500 DC were used in the experiment. Results of the metallographic research and mechanical tests are presented.

  14. Multi-color detection of gravitational arcs

    OpenAIRE

    Maturi, Matteo; Mizera, Sebastian; Seidel, Gregor

    2013-01-01

    Strong gravitational lensing provides fundamental insights into the understanding of the dark matter distribution in massive galaxies, galaxy clusters and the background cosmology. Despite their importance, the number of gravitational arcs discovered so far is small. The urge for more complete, large samples and unbiased methods of selecting candidates is rising. A number of methods for the automatic detection of arcs have been proposed in the literature, but large amounts of spurious detecti...

  15. A dosimetric phantom study of dose accuracy and build-up effects using IMRT and RapidArc in stereotactic irradiation of lung tumours

    OpenAIRE

    Seppala Jan; Suilamo Sami; Kulmala Jarmo; Mali Pekka; Minn Heikki

    2012-01-01

    Abstract Background and purpose Stereotactic lung radiotherapy (SLRT) has emerged as a curative treatment for medically inoperable patients with early-stage non-small cell lung cancer (NSCLC) and the use of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc treatments (VMAT) have been proposed as the best practical approaches for the delivery of SLRT. However, a large number of narrow field shapes are needed in the dose delivery of intensity-modulated techniques and the prob...

  16. Comparative study on pulsed arc discharge and pulsed corona like discharge in water

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Y.; Yan, H.; Zhang, Z.; Li, S.; Yan, K. [Zhejiang Univ., Hangzhou (China). Industrial Ecology and Environment Research Inst.

    2010-07-01

    Electric discharge in water generates intense UV radiation, shockwaves, and active radicals. The technology of pulsed discharge in water has broad applications in marine services, medical treatment and environmental pollution control. This study compared pulsed arc discharge and pulsed corona like discharge using a homemade all solid-state pulsed power system. Voltage and current waveforms, light emission and shockwave strength were detected simultaneously to calculate energy partition of both kinds of pulsed discharge. The differences in current, light emission and shockwave strength were presented. The study showed that energy injection into plasma of pulsed arc discharge varies with the breakdown time, while pulsed corona like discharge has a stable energy injection. A time lag between the application of voltage and breakdown was observed in both pulsed arc discharge and pulsed corona like discharge. The peak current and the light emission of the pulsed arc discharge was much bigger than the pulsed corona discharge, but the difference of shockwave strength was not as obvious. It was concluded that the pulsed arc discharge is more suitable for treating waste water and disinfecting drinking water because of its stronger UV light emission. In marine service, pulsed corona like discharge is more suitable because of its comparative shockwave strength and its stable discharge process. 11 refs., 1 tab., 7 figs.

  17. Optical emission from a small scale model electric arc furnace in 250-600 nm region

    Science.gov (United States)

    Mäkinen, A.; Niskanen, J.; Tikkala, H.; Aksela, H.

    2013-04-01

    Optical emission spectroscopy has been for long proposed for monitoring and studying industrial steel making processes. Whereas the radiative decay of thermal excitations is always taking place in high temperatures needed in steel production, one of the most promising environment for such studies are electric arc furnaces, creating plasma in excited electronic states that relax with intense characteristic emission in the optical regime. Unfortunately, large industrial scale electric arc furnaces also present a challenging environment for optical emission studies and application of the method is not straightforward. To study the usability of optical emission spectroscopy in real electric arc furnaces, we have developed a laboratory scale DC electric arc furnace presented in this paper. With the setup, optical emission spectra of Fe, Cr, Cr2O3, Ni, SiO2, Al2O3, CaO, and MgO were recorded in the wavelength range 250-600 nm and the results were analyzed with the help of reference data. The work demonstrates that using characteristic optical emission, obtaining in situ chemical information from oscillating plasma of electric arc furnaces is indeed possible. In spite of complications, the method could possibly be applied to industrial scale steel making process in order to improve its efficiency.

  18. Electric arc furnace models for flicker study

    Directory of Open Access Journals (Sweden)

    Catalina González Castaño

    2016-06-01

    Full Text Available Objective: The aim of this paper is to evaluate voltage fluctuations or flicker of two electric arc furnace models through comparison with real data.Method: The first proposed model is founded on the energy conservation principle, which generates a non-linear differential equation modelling the electric arc voltage – current characteristics. Voltage fluctuations are generated using a chaotic circuit that modulates the amplitude of arc voltage. The second model is based on the empirical relationship between the arc diameter or length as well as voltage and electrical current on the arc. Voltage fluctuations are considered adding a random signal in the arc length. Both models are implemented in PSCADTM.Results: The results of both models are compared with real data taken at the most critical stage of the operation of the furnace, and they show that the model based on energy conservation has a lower average mean square error in the voltages and currents 5.6 V and 1.7 kA against 27,2 V y 3.38 kA obtained with the second model.Conclusions: Both models consider the nonlinearity and random behavior present in this type of load, validating their inclusion in computer models of electric power systems.

  19. Recent ARC developments: Through modularity to interoperability

    Energy Technology Data Exchange (ETDEWEB)

    Smirnova, O; Cameron, D; Ellert, M; Groenager, M; Johansson, D; Kleist, J [NDGF, Kastruplundsgade 22, DK-2770 Kastrup (Denmark); Dobe, P; Joenemo, J; Konya, B [Lund University, Experimental High Energy Physics, Institute of Physics, Box 118, SE-22100 Lund (Sweden); Fraagaat, T; Konstantinov, A; Nilsen, J K; Saada, F Ould; Qiang, W; Read, A [University of Oslo, Department of Physics, P. O. Box 1048, Blindern, N-0316 Oslo (Norway); Kocan, M [Pavol Jozef Safarik University, Faculty of Science, Jesenna 5, SK-04000 Kosice (Slovakia); Marton, I; Nagy, Zs [NIIF/HUNGARNET, Victor Hugo 18-22, H-1132 Budapest (Hungary); Moeller, S [University of Luebeck, Inst. Of Neuro- and Bioinformatics, Ratzeburger Allee 160, D-23538 Luebeck (Germany); Mohn, B, E-mail: oxana.smirnova@hep.lu.s [Uppsala University, Department of Physics and Astronomy, Div. of Nuclear and Particle Physics, Box 535, SE-75121 Uppsala (Sweden)

    2010-04-01

    The Advanced Resource Connector (ARC) middleware introduced by NorduGrid is one of the basic Grid solutions used by scientists worldwide. While being well-proven in daily use by a wide variety of scientific applications at large-scale infrastructures like the Nordic DataGrid Facility (NDGF) and smaller scale projects, production ARC of today is still largely based on conventional Grid technologies and custom interfaces introduced a decade ago. In order to guarantee sustainability, true cross-system portability and standards-compliance based interoperability, the ARC community undertakes a massive effort of implementing modular Web Service (WS) approach into the middleware. With support from the EU KnowARC project, new components were introduced and the existing key ARC services got extended with WS technology based standard-compliant interfaces following a service-oriented architecture. Such components include the hosting environment framework, the resource-coupled execution service, the re-engineered client library, the self-healing storage solution and the peer-to-peer information system, to name a few. Gradual introduction of these new services and client tools into the production middleware releases is carried out together with NDGF and thus ensures a smooth transition to the next generation Grid middleware. Standard interfaces and modularity of the new component design are essential for ARC contributions to the planned Universal Middleware Distribution of the European Grid Initiative.

  20. Recent ARC developments: Through modularity to interoperability

    International Nuclear Information System (INIS)

    The Advanced Resource Connector (ARC) middleware introduced by NorduGrid is one of the basic Grid solutions used by scientists worldwide. While being well-proven in daily use by a wide variety of scientific applications at large-scale infrastructures like the Nordic DataGrid Facility (NDGF) and smaller scale projects, production ARC of today is still largely based on conventional Grid technologies and custom interfaces introduced a decade ago. In order to guarantee sustainability, true cross-system portability and standards-compliance based interoperability, the ARC community undertakes a massive effort of implementing modular Web Service (WS) approach into the middleware. With support from the EU KnowARC project, new components were introduced and the existing key ARC services got extended with WS technology based standard-compliant interfaces following a service-oriented architecture. Such components include the hosting environment framework, the resource-coupled execution service, the re-engineered client library, the self-healing storage solution and the peer-to-peer information system, to name a few. Gradual introduction of these new services and client tools into the production middleware releases is carried out together with NDGF and thus ensures a smooth transition to the next generation Grid middleware. Standard interfaces and modularity of the new component design are essential for ARC contributions to the planned Universal Middleware Distribution of the European Grid Initiative.

  1. New method for capturing arc of moving on switching apparatus

    Institute of Scientific and Technical Information of China (English)

    LIU Jiao-min; WANG Jing-hong

    2007-01-01

    The switching arc that occurs in contact gap when contact of low voltage apparatus closes or breaks in electric circuit is harmful to the contacts, insulation, and reliability of electrical gear because of its very high temperature. As arcing time is very short in switching gear, it is very difficult to observe arc phenomena directly for researchers. Therefore, visualization of switching arc is important for understanding arc phenomena, to analyze the arc features, and to improve the design and reliability of switching gear. Based on analyzing the visualization methods proposed by researchers, a new switching arc capturing approach is introduced in this paper. Arc image acquisition, and image processing techniques were studied. A switching arc image acquisition and visual simulation software based on high speed CCD camera hard ware system was designed and implemented to yield enhanced arc image with good visual effect.

  2. NEW DRUG DELIVERY SYSTEM

    Directory of Open Access Journals (Sweden)

    Sarkar Biresh K

    2011-05-01

    Full Text Available Incorporating an existing medicine into a new drug delivery system can significantly improve its performance in terms of efficacy, safety, and improved patient compliance. The need for delivering drugs to patients efficiently and with fewer side effects has prompted pharmaceutical companies to engage in the development of new drug delivery systems. Today, drug delivery companies are engaged in the development of multiple platform technologies for controlled release, delivery of large molecules, liposome, taste-masking, oral fast- dispersing dosage forms, technology for in- soluble drugs, and delivery of drugs through intranasal, pulmonary, transdermal, vaginal, colon, and transmucosal routes.

  3. Analysis of Emission Spectra from Arc-jet Shock Layer Flows

    Science.gov (United States)

    Gokcen, T.; Park, C. S.; Newfield, M. E.; Fletcher, D. G.; Langhoff, Stephen R. (Technical Monitor)

    1997-01-01

    This paper reports computational comparisons with experimental studies of a nonequilibrium blunt body shock layer in a high enthalpy arc-jet wind tunnel at NASA Ames Research Center. The primary objective of this work is to investigate the existence of a thermochemical equilibrium region in the shock layer. The existence of such an equilibrium region is of interest for following reasons: (1) to understand the equilibration process behind the shock in an arc-jet flow environment; (2) to interpret measured surface heat transfer data for purpose of determining surface catalytic efficiency, and (3) to determine the total enthalpy from the spectroscopic measurements. The paper will present an analysis of the experimental data obtained in the arc-jet wind tunnel. Experimental data includes measurements of emission spectra of radiation emanating from a shock layer formed in front of a 6-inch flat-faced cylinder. The measurements, obtained using a two dimensional CCD camera mounted on a spectrograph, provide spatially resolved spectra along the stagnation streamline of the model. Computational analysis includes simulation of nonequilibrium flow in the arc-jet facility (flow in the conical nozzle and shock layer in front of a flat-faced cylinder) using 2-D/axisymmetric Navier-Stokes codes and prediction of the radiation spectra from the axisymmetric flowfield using NEQAIR radiation code. Various line-of-sight averaged flow properties such as vibrational and rotational temperatures, species number densities within the shock layer are deduced from the experimental spectra. Comparison of the computed and experimental line-of-sight averaged flow properties provides assessment of thermochemical equilibration processes in an arc-jet shock layer.

  4. Vacuum arc under axial magnetic fields: experimental and simulation research

    International Nuclear Information System (INIS)

    Axial magnetic field (AMF) technology is a most important control method of vacuum arc, particularly for high-current vacuum arcs in vacuum interrupters. In this paper, a review of the state of current research on vacuum arcs under AMF is presented. The major aspects of vacuum arc in an AMF such as arc voltage, the motion of cathode spots, and anode activities are discussed, and the most recent progress both of experimental and simulation research is presented. (topical review)

  5. Direct probing of anode arc root dynamics and voltage instability in a dc non-transferred arc plasma jet

    Science.gov (United States)

    Ghorui, S.; Tiwari, N.; Meher, K. C.; Jan, A.; Bhat, A.; Sahasrabudhe, S. N.

    2015-12-01

    The transient dynamics of the anode arc root in a dc non-transferred arc plasma torch is captured through fast photography and directly correlated with the associated voltage instability for the first time. The coexistence of multiple arc roots, the transition to a single arc root, root formation and extinction are investigated for the steady, takeover and re-strike modes of the arc. Contrary to the usual concept, the emerging plasma jet of a dc non-transferred arc plasma torch is found to carry current. An unusually long self-propelled arc plasma jet, a consequence of the phenomenon, is demonstrated.

  6. Active Extraction of Near-field Thermal Radiation

    Science.gov (United States)

    Ding, Ding; Kim, Taeyong; Minnich, Austin

    Radiative heat transport between materials supporting surface-phonon polaritons is greatly enhanced when the materials are placed at sub-wavelength separation as a result of the contribution of near-field surface modes. However, the enhancement is limited to small separations due to the evanescent decay of the surface waves. In this work, we propose and numerically demonstrate an active radiative cooling (ARC) scheme to extract these modes to the far-field. Our approach exploits the monochromatic nature of near-field thermal radiation to drive a transition in a laser gain medium, which, when coupled with external optical pumping, allows the resonant surface mode to be emitted into the far-field. We also provide further insights into our ARC scheme by applying the theoretical framework used for laser cooling of solids (LCS) to ARC. We show that LCS and ARC can be described with the same mathematical formalism by replacing the electron-phonon coupling parameter in LCS with the electron-photon coupling parameter in ARC. Using this framework, we examine the predictions of the formalism for LCS and ARC using realistic parameters and find that ARC can achieve higher efficiency and extracted power over a wide range of conditions. Our study demonstrates a new approach to manipulate near-field thermal radiation for thermal management.

  7. Initiation of extended arc discharge in ICF reactor dense atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Kislev, H.

    1986-01-01

    Reduced density plasma channels are essential for LIB transport from external diodes to an ICF pellet centered in the 2-4 MPa superheated steamfilled cavity of the Heavy Water ICF Reactor. Forming such channels by ohmic heating requires the initiation of straight arc discharges along each beamline. The goal of this thesis is to evaluate the threshold beamline preionization and applied electric field for arc initiation. The capability of several preionizers to produce a straight preionized trail is evaluated through a ten-group Boltzmann equation solver. Electron densities around 10/sup 17/ m/sup -3/ could be maintained in the trail by monojoule output external preionizers. Trail preionization through the co-application of UV and CO/sub 2/ lasers appears to be the most promising technique. UV laser preionization of NO(a/sup 4/..pi..) formed in the fireball shows also good prospective. The large divergence of soft x-ray sources reduces their attractivity. The E/N dependent electron transport properties are used to construct the first streamer model capable of evaluating the steady state streamer wave shape. The streamers-induced highly ionized filament transition into a multi-kA carrying plasma channel is simulated by a modified radiation-MHD one-dimensional code.

  8. Episodicity in back-arc tectonic regimes

    Science.gov (United States)

    Clark, Stuart R.; Stegman, Dave; Müller, R. Dietmar

    2008-12-01

    The evolution of back-arc basins is tied to the development of the dynamics of the subduction system they are a part of. We present a study of back-arc basins and model their development by implementing 3D time-dependant computer models of subduction including an overriding plate. We define three types of episodicity: pseudo-, quasi- and hyper-episodicity, and find evidence of these in nature. Observations of back-arc basin ages, histories of spreading, quiescence and compression in the overriding plate give us an understanding of the time-development of these subduction zones and back-arc basins. Across the globe today, a number of trenches are advancing—the Izu-Bonin Trench, the Mariana Trench, the Japan Trench, the Java-Sunda Trench and the central portion of the Peru-Chile Trench (the Andes subduction zone). The Izu-Bonin, Mariana and Japan all have established back-arc basins, while the others have documented episodes of spreading, quiescence, compression or a combination of these. The combination of advancing and retreating trench motion places these subduction zones in the category of hyper-episodicity. Quasi-episodicity, in which the back-arc shifts between phases of rifting, spreading and quiescence, is the dominant form of episodic back-arc development in the present. We find this type of episodicity in models for which the system is dynamically consistent—that we have allowed the subducting plate's velocity to be determined by the sinking slabs' buoyancy. Quasi- and hyper-episodicity are only found in subduction zones with relatively high subducting plate velocities, between 6 and 9 cm/year. Finally, those subduction zones for which the subducting plate is moving slowly, such as in the Mediterranean or the Scotia Sea, experience only pseudo-episodicity, where the spreading moves linearly towards the trench but often does so in discrete ridge-jump events.

  9. Towards Understanding the Sunda and Banda Arcs

    Science.gov (United States)

    Hall, R.

    2014-12-01

    The present change from oceanic subduction beneath the Sunda Arc to arc-continent collision east of Sumba is merely the latest stage in a complex collision history that began more than 20 million years ago. Understanding present-day tectonics requires restoring the pre-collisional margins and unravelling the history of the entire Sunda-Banda Arc, not just a segment centred on Sumba. Seismic tomography displays a single folded slab beneath the Banda Arc around which mantle has flowed. Above this is a wide actively deforming zone of complex geology. Australian crust was first added to the Sunda margin in the Cretaceous. Early Miocene closure of the oceanic gap north of Australia led to further additions of continental crust during collision of the Sula Spur. Few microcontinental fragments were sliced from New Guinea as commonly interpreted. Most are parts of the Sula Spur fragmented by extension and strike-slip faulting during development of subduction zones and rollback into the Banda embayment. Many metamorphic 'basement' rocks are significantly younger than expected. They were metamorphosed during multiple episodes of extension which also exhumed the sub-lithospheric mantle, melted the deep continental crust, created new ocean basins, and dispersed continental crust throughout the inner and outer arc, and forearc, so that in places Australian crust is colliding with Australian crust. Thus, many of the arc volcanoes are built on continental not oceanic crust, and sediment eroded from recently emergent islands is compositionally different to subducted sediment that contributed to arc magmas. The published literature is inadequate. New fieldwork and data are required, particularly in remote areas, with integration of information from a variety of sources (e.g. industry seismic and multibeam bathymetry, remotely acquired imagery) and sub-disciplines (e.g. geochronology, geochemistry, seismology, modelling). No single methodology can provide a complete solution.

  10. arcControlTower: the System for Atlas Production and Analysis on ARC

    Science.gov (United States)

    Filipčič, Andrej; ATLAS Collaboration

    2011-12-01

    PanDA, the Atlas management and distribution system for production and analysis jobs on EGEE and OSG clusters, is based on pilot jobs to increase the throughput and stability of the job execution on grid. The ARC middleware uses a specific approach which tightly connects the job requirements with cluster capabilities like resource usage, software availability and caching of input files. The pilot concept renders the ARC features useless. The arcControlTower is the job submission system which merges the pilot benefits and ARC advantages. It takes the pilot payload from the panda server and submits the jobs to the Nordugrid ARC clusters as regular jobs, with all the job resources known in advance. All the pilot communication with the PanDA server is done by the arcControlTower, so it plays the role of a pilot factory and the pilot itself. There are several advantages to this approach: no grid middleware is needed on the worker nodes, the fair-share between the production and user jobs is tuned with the arcControlTower load parameters, the jobs can be controlled by ARC client tools. The system could be extended to other submission systems using central distribution.

  11. arcControlTower: the System for Atlas Production and Analysis on ARC

    International Nuclear Information System (INIS)

    PanDA, the Atlas management and distribution system for production and analysis jobs on EGEE and OSG clusters, is based on pilot jobs to increase the throughput and stability of the job execution on grid. The ARC middleware uses a specific approach which tightly connects the job requirements with cluster capabilities like resource usage, software availability and caching of input files. The pilot concept renders the ARC features useless. The arcControlTower is the job submission system which merges the pilot benefits and ARC advantages. It takes the pilot payload from the panda server and submits the jobs to the Nordugrid ARC clusters as regular jobs, with all the job resources known in advance. All the pilot communication with the PanDA server is done by the arcControlTower, so it plays the role of a pilot factory and the pilot itself. There are several advantages to this approach: no grid middleware is needed on the worker nodes, the fair-share between the production and user jobs is tuned with the arcControlTower load parameters, the jobs can be controlled by ARC client tools. The system could be extended to other submission systems using central distribution.

  12. Effect of arc distance on temperature field and weld shape during double-sided arc welding

    Institute of Scientific and Technical Information of China (English)

    ZHANG Guangjun; ZHANG Huajun; GAO Hongming; WU Lin

    2009-01-01

    A new high efficiency welding method, double-sided double arc welding with double powers (DSAW-D), is developed for thick plate of low alloy high strength steel in this study. It is well known that the thermal cycles have an important influence on the microstructure, shape, stress, distortion and mechanical property. The DSA W-D method can control the tempernture field on a wide range by regulating the distance between two arcs, improve the rnicrostructure and prevent hot and cold cracking of high strength steel. But at present, the effect of arc distance on the temperature field and shape is not clear. Therefore, the paper researches the effect of arc distance on the temperature field and weld pool during DSA W-D using finite element method. The transient temperature field of different arc distance in DSAW-D is calculated.To verify the numerical results, the temperature is measured by the thermo-couple and the calculated results agree approximately with experimental data. Farther, the thermal property and mutual effect of double-sided arcs are investigated. The temperature distributions and weld pool profile at different arc distances are obtained. The results show that arc distance is a very important factor to affect the heat process.

  13. Effects of process parameters on arc shape and penetration in twin-wire indirect arc welding

    Institute of Scientific and Technical Information of China (English)

    Shun-shan ZHANG; Mei-qing CAO; Dong-ting WU; Zeng-da ZOU

    2009-01-01

    In this study, the effects of variable parameters on arc shape and depth of penetration in twin-wire indirect arc gas shielded welding were investigated. The variation of arc shape caused by changes of the parameters was recorded by a high-speed camera,and the depths of penetration of specimen were measured after bead welding by an optical microscope. Experiments indicated that proper parameters give birth to a concentrated and compressed welcimg arc, which Would increase the depth of penetration as the incensement of the arc foice Several pnncipal parameters including toe distance ot twin wires intersecting point to base metal,the included angle,and the content of shielding gas were determined. The arc turned more concentrated and the depth of penetration increased obviously as the welding current increased,the arc turned brighter while unobvlous change of penetration occurred as the arc voltage increased,and the deepest penetration was obtained when the welding speed was 10.5 mm/s..

  14. A lower bound for the node, edge, and arc routing problem

    DEFF Research Database (Denmark)

    Bach, Lukas; Hasle, Geir; Wøhlk, Sanne

    2013-01-01

    The Node, Edge, and Arc Routing Problem (NEARP) was defined by Prins and Bouchenoua in 2004, although similar problems have been studied before. This problem, also called the Mixed Capacitated General Routing Problem (MCGRP), generalizes the classical Capacitated Vehicle Routing Problem (CVRP......), the Capacitated Arc Routing Problem (CARP), and the General Routing Problem. It captures important aspects of real-life routing problems that were not adequately modeled in previous Vehicle Routing Problem (VRP) variants. The authors also proposed a memetic algorithm procedure and defined a set of test instances...... the CBMix benchmark. The first is based on well-known CARP instances; the second consists of real life cases of newspaper delivery routing. We provide numerical results in the form of lower and best known upper bounds for all instances of all three benchmarks. For three of the instances, the gap between...

  15. Overview of ArcGIS Engine Controls%ArcGIS Engine控件综述

    Institute of Scientific and Technical Information of China (English)

    刘磊

    2010-01-01

    ArcGIS Engine是ESRI公司发布的嵌入式地理信息系统软件开发包.基于ArcGIS Engine开发的应用程序一般有3类:独立非可视化应用程序、独立可视化应用程序和嵌入式应用程序,由于ArcGIS Engine提供了一套可复用、跨平台、设计良好的ArcGIS控件,因此利用控件开发可视化的GIS应用程序是一种常用的开发方式.重点探讨了ArcGIS Engine自带控件的功能、使用方法以及与伙伴控件之间的联系机制.

  16. Method to reduce arc blow during DC arc welding of pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Espina-Hernandez, J. H.; Rueda-Morales, G.L.; Caleyo, F.; Hallen, J. M. [Instituto Politecnico Nacional, Mexico, (Mexico); Lopez-Montenegro, A.; Perz-Baruch, E. [Pemex Exploracion y Produccion, Tabasco, (Mexico)

    2010-07-01

    Steel pipelines are huge ferromagnetic structures and can be easily subjected to arc blow during the DC arc welding process. The development of methods to avoid arc blow during pipeline DC arc welding is a major objective in the pipeline industry. This study developed a simple procedure to compensate the residual magnetic field in the groove during DC arc welding. A Gaussmeter was used to perform magnetic flux density measurements in pipelines in southern Mexico. These data were used to perform magnetic finite element simulations using FEMM. Different variables were studied such as the residual magnetic field in the groove or the position of the coil with respect to the groove. An empirical predictive equation was developed from these trials to compensate for the residual magnetic field. A new method of compensating for the residual magnetic field in the groove by selecting the number of coil turns and the position of the coil with respect to the groove was established.

  17. Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines

    Science.gov (United States)

    Cong, Haoxi; Li, Qingmin; Xing, Jinyuan; Li, Jinsong; Chen, Qiang

    2015-06-01

    The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low-voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines. supported by National Natural Science Foundation of China (Nos. 51277061 and 51420105011)

  18. The geochemistry and petrogenesis of the Paleoproterozoic Green Mountain arc: A composite(?), bimodal, oceanic, fringing arc

    Science.gov (United States)

    Jones, D.S.; Barnes, C.G.; Premo, W.R.; Snoke, A.W.

    2011-01-01

    The inferred subduction affinity of the ~1780-Ma Green Mountain arc, a dominantly bimodal igneous terrane (together with immature marine and volcaniclastic sedimentary rocks) accreted to the southern margin of the Wyoming province, is integral to arc-accretion models of the Paleoproterozoic growth of southern Laurentia. Conversely, the dominantly bimodal nature of many putative arc-related igneous suites throughout southern Laurentia, including the Green Mountain arc, has also been used to support models of growth by extension of pre-existing crust. We report new geochemical and isotopic data from ~1780-Ma gabbroic and granodioritic to tonalitic rocks of the Big Creek Gneiss, interpreted as consanguineous with previously studied metavolcanic rocks of the Green Mountain Formation.The ~1780-Ma Big Creek Gneiss mafic rocks show clear geochemical signatures of a subduction origin and provide no supporting evidence for extensional tectonism. The ~1780-Ma Big Creek Gneiss felsic rocks are attributed to partial melting of mafic and/or mixed lower-crustal material. The bimodal nature of the suite results from the combination of arc basalts and felsic crustal melts. The lack of andesite is consistent with the observed tholeiitic differentiation trend of the mafic magmas. The lower e{open}Nd(1780Ma) values for the felsic rocks vs. the mafic rocks suggest that the unexposed lower crust of the arc may be older than the arc and that Trans-Hudson- or Penokean-aged rocks possibly form the substratum of the arc. Our results reinforce previous interpretations that arc-related magmatism played a key role in the Paleoproterozoic crustal growth of southern Laurentia, but also support the possibility of unexposed older crust as basement to the arcs. ?? 2011 Elsevier B.V.

  19. BASIC THEORY AND METHOD OF WELDING ARC SPECTRAL INFORMATION

    Institute of Scientific and Technical Information of China (English)

    Li Junyue; Li Zhiyong; Li Huan; Xue Haitao

    2004-01-01

    Arc spectral information is a rising information source which can solve many problems that can not be done with arc electric information and other arc information.It is of important significance to develop automatic control technique of welding process.The basic theory and methods on it play an important role in expounding and applying arc spectral information.Using concerned equation in plasma physics and spectrum theory,a system of equations including 12 equations which serve as basic theory of arc spectral information is set up.Through analyzing of the 12 equations,a basic view that arc spectral information is the reflection of arc state and state variation,and is the most abundant information resource reflecting welding arc process is drawn.Furthermore,based on the basic theory,the basic methods of test and control of arc spectral information and points out some applications of it are discussesed.

  20. Arc modelling in SF{sub 6} circuit breakers

    Energy Technology Data Exchange (ETDEWEB)

    Verite, J.C. [Electricite de France, Clamart (France). Derection des Etudes et Recherches; Boucher, T.; Comte, A. [Electricite de France, Moret sur Loing (France). Direction des Etudes et Recherches; Delalondre, C. [Electricite de France, Chatou (France). Direction des Etudes et Recherches; Robin-Jouan, P.; Serres, E.; Texier, V. [GEC Alsthom, Villeurbanne (France). Direction Technique Haute et Moyenne Tension; Barrault, M.; Chevrier, P.; Fievet, C. [CEA Centre d`Etudes Nucleaires de Grenoble, 38 (France). Merlin Gerin

    1995-06-01

    The paper presents the work done by an operator, EDF and two manufacturers to improve the physical models and numerical methods used to simulate the behavior of the plasma and cold gas around it in a breaking chamber of the HV SF6 circuit breaker, during the high-current phase. This work concerns flow phenomena, in particular incorporating compressibility and the study of turbulence, the coupling between these flow phenomena and electromagnetic phenomena, and finally, radiation - which plays an essential role in energy transfer during the high-current phase. For this latter aspect, emission but also absorption were proven to play a major role, and the two were introduced into the models. The paper presents the models developed and the results obtained with them for simulation of two circuit breaker mock-ups (a double-pressure circuit breaker mock-up and a self-expanding and rotating arc circuit breaker mock-up). (author) 10 refs.

  1. Volumetric modulated arc therapy and breath-hold in image-guided locoregional left-sided breast irradiation

    NARCIS (Netherlands)

    Osman, S.O.; Hol, S.; Poortmans, P.M.P.; Essers, M.

    2014-01-01

    PURPOSE: To investigate the effects of using volumetric modulated arc therapy (VMAT) and/or voluntary moderate deep inspiration breath-hold (vmDIBH) in the radiation therapy (RT) of left-sided breast cancer including the regional lymph nodes. MATERIALS AND METHODS: For 13 patients, four treatment co

  2. Health care delivery systems.

    OpenAIRE

    Stevens, F; Zee, J. van der

    2007-01-01

    A health care delivery system is the organized response of a society to the health problems of its inhabitants. Societies choose from alternative health care delivery models and, in doing so, they organize and set goals and priorities in such a way that the actions of different actors are effective, meaningful, and socially accepted. From a sociological point of view, the analysis of health care delivery systems implies recognition of their distinct history over time, their specific values an...

  3. Project delivery system (PDS)

    CERN Document Server

    2001-01-01

    As business environments become increasingly competitive, companies seek more comprehensive solutions to the delivery of their projects. "Project Delivery System: Fourth Edition" describes the process-driven project delivery systems which incorporates the best practices from Total Quality and is aligned with the Project Management Institute and ISO Quality Standards is the means by which projects are consistently and efficiently planned, executed and completed to the satisfaction of clients and customers.

  4. Volumetric-modulated arc therapy planning using multicriteria optimization for localized prostate cancer.

    Science.gov (United States)

    Ghandour, Sarah; Matzinger, Oscar; Pachoud, Marc

    2015-01-01

    The purpose of this work is to evaluate the volumetric-modulated arc therapy (VMAT) multicriteria optimization (MCO) algorithm clinically available in the RayStation treatment planning system (TPS) and its ability to reduce treatment planning time while providing high dosimetric plan quality. Nine patients with localized prostate cancer who were previously treated with 78 Gy in 39 fractions using VMAT plans and rayArc system based on the direct machine parameter optimization (DMPO) algorithm were selected and replanned using the VMAT-MCO system. First, the dosimetric quality of the plans was evaluated using multiple conformity metrics that account for target coverage and sparing of healthy tissue, used in our departmental clinical protocols. The conformity and homogeneity index, number of monitor units, and treatment planning time for both modalities were assessed. Next, the effects of the technical plan parameters, such as constraint leaf motion CLM (cm/°) and maximum arc delivery time T (s), on the accuracy of delivered dose were evaluated using quality assurance passing rates (QAs) measured using the Delta4 phantom from ScandiDos. For the dosimetric plan's quality analysis, the results show that the VMAT-MCO system provides plans comparable to the rayArc system with no statistical difference for V95% (p < 0.01), D1% (p < 0.01), CI (p < 0.01), and HI (p < 0.01) of the PTV, bladder (p < 0.01), and rectum (p < 0.01) constraints, except for the femoral heads and healthy tissues, for which a dose reduction was observed using MCO compared with rayArc (p < 0.01). The technical parameter study showed that a combination of CLM equal to 0.5 cm/degree and a maximum delivery time of 72 s allowed the accurate delivery of the VMAT-MCO plan on the Elekta Versa HD linear accelerator. Planning evaluation and dosimetric measurements showed that VMAT-MCO can be used clinically with the advantage of enhanced planning process efficiency by reducing the treatment planning time

  5. Feasibility of single-isocenter, multi-arc non-coplanar volumetric modulated arc therapy for multiple brain tumors using a linear accelerator with a 160-leaf multileaf collimator: a phantom study.

    Science.gov (United States)

    Iwai, Yoshio; Ozawa, Shuichi; Ageishi, Tatsuya; Pellegrini, Roberto; Yoda, Kiyoshi

    2014-09-01

    The feasibility of single isocenter, multi-arc non-coplanar volumetric modulated arc therapy (VMAT) for multiple brain tumors was studied using an Elekta Synergy linear accelerator with an Agility multileaf collimator and a Monaco treatment planning system. Two VMAT radiosurgery plans consisting of a full arc and three half arcs were created with a prescribed dose of 20 Gy in a single fraction. After dose delivery to a phantom, ionization chambers and radiochromic films were used for dose measurement. The first VMAT radiosurgery plan had nine targets inside the phantom, and the doses were measured by the chambers at two different points and by the films on three sagittal and three coronal planes. The differences between the calculated dose and the dose measured by a Farmer ionization chamber and a pinpoint ionization chamber were radiosurgery plan was based on a clinical 14 brain metastases. Differences between calculated and film-measured doses were evaluated on two sagittal planes. The average pass rates of the gamma indices on the planes under each of 3%/3 mm and 2%/2 mm criteria were 97.8% and 88.8%, respectively. It was confirmed that single-isocenter, non-coplanar multi-arc VMAT radiosurgery for multiple brain metastases was feasible using Elekta Synergy with Agility and Monaco treatment planning systems. It was further shown that film dosimetry was accurately performed for a dose of up to nearly 25 Gy. PMID:24944266

  6. Circular arc snakes and kinematic surface generation

    KAUST Repository

    Barton, Michael

    2013-05-01

    We discuss the theory, discretization, and numerics of curves which are evolving such that part of their shape, or at least their curvature as a function of arc length, remains unchanged. The discretization of a curve as a smooth sequence of circular arcs is well suited for such purposes, and allows us to reduce evolution of curves to the evolution of a control point collection in a certain finite-dimensional shape space. We approach this evolution by a 2-step process: linearized evolution via optimized velocity fields, followed by optimization in order to exactly fulfill all geometric side conditions. We give applications to freeform architecture, including "rationalization" of a surface by congruent arcs, form finding and, most interestingly, non-static architecture. © 2013 The Author(s) Computer Graphics Forum © 2013 The Eurographics Association and Blackwell Publishing Ltd.

  7. Magnesium isotope geochemistry in arc volcanism.

    Science.gov (United States)

    Teng, Fang-Zhen; Hu, Yan; Chauvel, Catherine

    2016-06-28

    Incorporation of subducted slab in arc volcanism plays an important role in producing the geochemical and isotopic variations in arc lavas. The mechanism and process by which the slab materials are incorporated, however, are still uncertain. Here, we report, to our knowledge, the first set of Mg isotopic data for a suite of arc lava samples from Martinique Island in the Lesser Antilles arc, which displays one of the most extreme geochemical and isotopic ranges, although the origin of this variability is still highly debated. We find the δ(26)Mg of the Martinique Island lavas varies from -0.25 to -0.10, in contrast to the narrow range that characterizes the mantle (-0.25 ± 0.04, 2 SD). These high δ(26)Mg values suggest the incorporation of isotopically heavy Mg from the subducted slab. The large contrast in MgO content between peridotite, basalt, and sediment makes direct mixing between sediment and peridotite, or assimilation by arc crust sediment, unlikely to be the main mechanism to modify Mg isotopes. Instead, the heavy Mg isotopic signature of the Martinique arc lavas requires that the overall composition of the mantle wedge is buffered and modified by the preferential addition of heavy Mg isotopes from fluids released from the altered subducted slab during fluid-mantle interaction. This, in turn, suggests transfer of a large amount of fluid-mobile elements from the subducting slab to the mantle wedge and makes Mg isotopes an excellent tracer of deep fluid migration. PMID:27303032

  8. Magnesium isotope geochemistry in arc volcanism

    Science.gov (United States)

    Teng, Fang-Zhen; Hu, Yan

    2016-01-01

    Incorporation of subducted slab in arc volcanism plays an important role in producing the geochemical and isotopic variations in arc lavas. The mechanism and process by which the slab materials are incorporated, however, are still uncertain. Here, we report, to our knowledge, the first set of Mg isotopic data for a suite of arc lava samples from Martinique Island in the Lesser Antilles arc, which displays one of the most extreme geochemical and isotopic ranges, although the origin of this variability is still highly debated. We find the δ26Mg of the Martinique Island lavas varies from −0.25 to −0.10, in contrast to the narrow range that characterizes the mantle (−0.25 ± 0.04, 2 SD). These high δ26Mg values suggest the incorporation of isotopically heavy Mg from the subducted slab. The large contrast in MgO content between peridotite, basalt, and sediment makes direct mixing between sediment and peridotite, or assimilation by arc crust sediment, unlikely to be the main mechanism to modify Mg isotopes. Instead, the heavy Mg isotopic signature of the Martinique arc lavas requires that the overall composition of the mantle wedge is buffered and modified by the preferential addition of heavy Mg isotopes from fluids released from the altered subducted slab during fluid−mantle interaction. This, in turn, suggests transfer of a large amount of fluid-mobile elements from the subducting slab to the mantle wedge and makes Mg isotopes an excellent tracer of deep fluid migration. PMID:27303032

  9. On the Trail of Joan of Arc

    Directory of Open Access Journals (Sweden)

    Linda Joyce Forristal

    2013-12-01

    Full Text Available The year 2012 marked the 600th anniversary of the birthday of Joan of Arc (Fr., Jeanne d’Arc (1412–1431. Tributes to this national heroine can be found all over France. There are literally countless statues, streets and restaurants named after her and many sites dedicated to her life. However, despite widespread social and mechanical reproduction and cultural naming in relation to the Maid of Orléans, there is no official network or integrated signage in France to promote cultural heritage tourism to the numerous Joan of Arc sites and festivals, even though her life and death, by any measure, were seminal events in the country’s history. Unfortunately, the pilgrim who wants to follow or intersect with Joan of Arc’s trail through France, for cultural, historical or religious reasons, must do so without much help. Using Actor Network Theory and Site Sacralization Theory as framing devices, this paper explores human actors and tangible and intangible non-human factors that may have contributed to the lack of a unified tourism product despite the existence of an adequate Joan of Arc tourismscape. Insights gleaned from this research include Joan’s conflicted status as both/either saint and/or patriot, the existence of no cooperation or linkage between Joan of Arc sites, and cautious French tourism development policies. Several possible scenarios are suggested as suitable means to help implement or foster the creation of an on-the-ground or virtual Joan of Arc trail or tour.

  10. Characterization of a high current pulsed arc using optical emission spectroscopy

    Science.gov (United States)

    Sousa Martins, R.; Zaepffel, C.; Chemartin, L.; Lalande, Ph; Soufiani, A.

    2016-10-01

    In this paper, we present the investigation realized on an experimental setup that simulates an arc column subjected to the transient phase of a lightning current waveform in laboratory conditions. Optical emission spectroscopy is employed to assess space- and time-resolved properties of this high current pulsed arc. Different current peak levels are utilised in this work, ranging from 10 kA to 100 kA, with a peak time around 15 µs. Ionic lines of nitrogen and oxygen are used to determine the radial profiles of temperature and electron density of the arc channel over time from 2 µs to 36 µs. A combination of 192 N II and O II lines is considered in the calculation of the bound-bound contribution of the absorption coefficient of the plasma channel. Calculations of the optical thickness showed that self-absorption of these ionic lines in the arc column is important. To obtain temperature and electron density profiles in the arc, we solved the radiative transfer equation across the channel under an axisymmetric assumption and considering the channel formed by uniform concentric layers. For the 100 kA current peak level, the temperature reaches more than 38 000 K and the electron density reaches 5  ×  1018 cm-3. The pressure inside the channel is calculated using the air plasma composition at local thermodynamic equilibrium, and reaches 45 bar. The results are discussed and utilised to estimate the electrical conductivity of the arc channel.

  11. arcControlTower: the System for Atlas Production and Analysis on ARC

    CERN Document Server

    Filipcic, A; The ATLAS collaboration

    2011-01-01

    PanDA, the Atlas management and distribution system for production and analysis jobs on EGEE and OSG clusters, is based on pilot jobs to increase the throughput and stability of the job execution on grid. The ARC middleware uses specific approach which tightly connects the job requirements with cluster capabilities like resource usage, software availability and caching of input files. The pilot concept renders the ARC features useless. The arcControlTower is the job submission system which merges the pilot benefits and ARC advantages. It takes the pilot payload from the panda server and submits the jobs to the Nordugrid ARC clusters as regular jobs, with all the job resources known in advance. All the pilot communication with the PanDA server is done by the arcControlTower, so it plays the role of a pilot factory and the pilot itself. There are several advantages to this approach: no grid middleware is needed on the worker nodes, the fair-share between the production and user jobs is tuned with the arcControl...

  12. A numerical simulation of ablation controlled arcs

    Energy Technology Data Exchange (ETDEWEB)

    Godin, D.; Trepanier, J.Y. [Ecole Polytechnique, Dept. of Mechanical Engineering, Montreal, PQ (Canada); Eby, S.D. [Ecole Polytechnique, Centre de Recherche en Calcul Applique, Montreal, PQ (Canada); Robin-Jouan, P. [GEC-Alsthom T and D, Villeurbanne, (France)

    1998-09-01

    An approach to model the ablation phenomenon of ablation controlled arcs using computational fluid dynamics was presented. Ablation controlled arcs are found in high voltage electrical equipment such as fuses and circuit-breakers. A qualitative prediction of the ablation level is critical from an industrial point of view because deliberate use of ablation is made to increase the pressure in a circuit-breaker chamber to allow for an efficient extinction when the current returns to zero. The numerical model was validated by comparing results of published experimental data. 7 refs., 10 figs.

  13. ArcAid interactive archery assistant

    OpenAIRE

    Jeroen Vervaeke; Jente Ameye; Sievert van Esch; Jelle Saldien; Steven Verstockt

    2015-01-01

    This paper describes the design process of a bow aiming system, called ArcAid, which is an interactive archery assistant. The main goal of ArcAid is to introduce a way for beginner Robin Hoods to learn the art of archery to its fullest. In order to achieve this goal, our smartphone-based design focuses on a fun and interactive learning process that gives constant feedback to the user on how to hit a certain goal. A SPIKE high- end laser sensor is used for the distance measurement and the smar...

  14. Electric-arc steam plasma generator

    Science.gov (United States)

    Anshakov, A. S.; Urbakh, E. K.; Radko, S. I.; Urbakh, A. E.; Faleev, V. A.

    2015-01-01

    Investigation results on the arc plasmatorch for water-steam heating are presented. The construction arrangement of steam plasma generator with copper electrodes of the stepped geometry was firstly implemented. The energy characteristics of plasmatorch and erosion of electrodes reflect the features of their behavior at arc glow in the plasma-forming environment of steam. The results of numerical study of the thermal state of the composite copper-steel electrodes had a significant influence on optimization of anode water-cooling aimed at improvement of its operation life.

  15. Architectural Surfaces and Structures from Circular Arcs

    KAUST Repository

    Shi, Ling

    2013-12-01

    In recent decades, the popularity of freeform shapes in contemporary architecture poses new challenges to digital design. One of them is the process of rationalization, i.e. to make freeform skins or structures affordable to manufacture, which draws the most attention from geometry researchers. In this thesis, we aim to realize this process with simple geometric primitives, circular arcs. We investigate architectural surfaces and structures consisting of circular arcs. Our focus is lying on how to employ them nicely and repetitively in architectural design, in order to decrease the cost in manufacturing. Firstly, we study Darboux cyclides, which are algebraic surfaces of order ≤ 4. We provide a computational tool to identify all families of circles on a given cyclide based on the spherical model of M ̈obius geometry. Practical ways to design cyclide patches that pass through certain inputs are presented. In particular, certain triples of circle families on Darboux cyclides may be suitably arranged as 3-webs. We provide a complete classification of all possible 3-webs of circles on Darboux cyclides. We then investigate the circular arc snakes, which are smooth sequences of circu- lar arcs. We evolve the snakes such that their curvature, as a function of arc length, remains unchanged. The evolution of snakes is utilized to approximate given surfaces by circular arcs or to generated freeform shapes, and it is realized by a 2-step pro- cess. More interestingly, certain 6-arc snake with boundary constraints can produce a smooth self motion, which can be employed to build flexible structures. Another challenging topic is approximating smooth freeform skins with simple panels. We contribute to this problem area by approximating a negatively-curved 5 surface with a smooth union of rational bilinear patches. We provide a proof for vertex consistency of hyperbolic nets using the CAGD approach of the rational B ́ezier form. Moreover, we use Darboux transformations for the

  16. Dynamic Arc-Flags in Road Networks

    OpenAIRE

    D 'angelo, Gianlorenzo; Frigioni, Daniele; Vitale, Camillo

    2011-01-01

    International audience In this work we introduce a new data structure, named Road-Signs, which allows us to efficiently update the Arc-Flags of a graph in a dynamic scenario. Road-Signs can be used to compute Arc-Flags, can be efficiently updated and do not require large space consumption for many real-world graphs like, e.g., graphs arising from road networks. In detail, we define an algorithm to preprocess Road-Signs and an algorithm to update them each time that a weight increase operat...

  17. Plasma distribution of cathodic ARC deposition system

    Energy Technology Data Exchange (ETDEWEB)

    Anders, S.; Raoux, S.; Krishnan, K.; MacGill, R.A.; Brown, I.G. [Lawrence Berkeley National Lab., CA (United States)

    1996-08-01

    The plasma distribution using a cathodic arc plasma source with and without magnetic macroparticle filter has been determined by depositing on a transparent plastic substrate and measuring the film absorption. It was found that the width of the distribution depends on the arc current, and it also depends on the cathode material which leads to a spatial separation of the elements when an alloy cathode is used. By applying a magnetic multicusp field near the exit of the magnetic filter, it was possible to modify the plasma distribution and obtain a flat plasma profile with a constant and homogeneous elemental distribution.

  18. Small Universal Petri Nets with Inhibitor Arcs

    OpenAIRE

    Ivanov, Sergiu; Pelz, Elisabeth; Verlan, Sergey

    2013-01-01

    We investigate the problem of construction of small-size universal Petri nets with inhibitor arcs. We consider four descriptional complexity parameters: the number of places, transitions, inhibitor arcs, and the maximal degree of a transition, each of which we try to minimize. We give six constructions having the following values of parameters (listed in the above order): $(30,34,13,3)$, $(14, 31, 51, 8)$, $(11, 31, 79, 11)$, $(21,25,13,5)$, $(67, 64, 8, 3)$, $(58, 55, 8, 5)$ that improve the...

  19. Arcing Model of a Disconnector and its Effect on VFTO

    International Nuclear Information System (INIS)

    In the computational process of very fast transient over-voltage (VFTO), it is essential to find an accurate model for a gas insulated substation. The arcing model of the disconnector is particularly important. The general arcing model is not able to give a good description of the arc development process. In this paper, based on the physical process of arcing and existing arc models (the exponential time-varying resistance model and the segmental arcing models), a dynamic arcing model is proposed, which is divided into two stages before and after the zero crossing. The dynamic arcing model combines hyperbola time-varying resistance and the Mayr model to describe the dynamic process of arcing. The present paper creates an arc model blockset upon the Matlab/Simulink software platform. Moreover for a specific 1100 kV station, VFTO is simulated in detail based on different arcing models. It is demonstrated that the dynamic arcing model can describe the physical arc process precisely and is useful for improving the accuracy of VFTO simulations

  20. Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool

    International Nuclear Information System (INIS)

    Purpose: The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. Methods: The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. Results: The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. Conclusions: Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.

  1. Prediction of preterm delivery

    NARCIS (Netherlands)

    F.F. Wilms

    2014-01-01

    Preterm delivery is in quantity and in severity an important issue in the obstetric care in the Western world. There is considerable knowledge on maternal and obstetric risk factors of preterm delivery. Of the women presenting with preterm labor, the majority is pregnant with a male fetus and in Cau

  2. Health care delivery systems.

    NARCIS (Netherlands)

    Stevens, F.; Zee, J. van der

    2007-01-01

    A health care delivery system is the organized response of a society to the health problems of its inhabitants. Societies choose from alternative health care delivery models and, in doing so, they organize and set goals and priorities in such a way that the actions of different actors are effective,

  3. Modeling Vacuum Arcs On Spacecraft Solar Panel Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Spacecraft charging and subsequent vacuum arcing poses a significant threat to satellites in LEO and GEO plasma conditions. Localized arc discharges can cause a...

  4. PNW River Reach Files -- 1:100k Watercourses (arcs)

    Data.gov (United States)

    Pacific States Marine Fisheries Commission — This feature class includes the ARC features from the 2001 version of the PNW River Reach files Arc/INFO coverage. Separate, companion feature classes are also...

  5. Rejuvenating Allen's Arc with the Geometric Mean.

    Science.gov (United States)

    Phillips, William A.

    1994-01-01

    Contends that, despite ongoing criticism, Allen's arc elasticity formula remains entrenched in the microeconomics principles curriculum. Reviews the evolution and continuing scrutiny of the formula. Argues that the use of the geometric mean offers pedagogical advantages over the traditional arithmetic mean approach. (CFR)

  6. Roadmap for the ARC Grid Middleware

    DEFF Research Database (Denmark)

    Kleist, Josva; Eerola, Paula; Ekelöf, Tord;

    2006-01-01

    The Advanced Resource Connector (ARC) or the NorduGrid middleware is an open source software solution enabling production quality computational and data Grids, with special emphasis on scalability, stability, reliability and performance. Since its first release in May 2002, the middleware is depl...

  7. Collection of arc welding process data

    Directory of Open Access Journals (Sweden)

    K. Luksa

    2006-04-01

    Full Text Available Purpose: The aim of the research was to examine the possibility of detecting welding imperfections by recording the instant values of welding parameters. The microprocessor controlled system for real-time collection and display of welding parameters was designed, implemented and tested.Design/methodology/approach: The system records up to 4 digital or analog signals collected from welding process and displays their run on the LCD display. To disturb the welding process artificial disturbances were introduced.Findings: The occurrence of some welding imperfections is followed by changes of the welding parameters. In this case they can be revealed by the analysis of the instant values of the welding parameters.Research limitations/implications: In the paper results of monitoring manual metal arc welding and gas metal arc welding are presented.Practical implications: Monitoring of gas metal arc welding is a good tool for evaluation of the quality of weld. All introduced, artificial disturbances of the welding process destabilize the welding arc and produce changes in the instant values of the welding parameters.Originality/value: The paper presents a modern microprocessor controlled system for real-time collection and display of welding parameters. Results of tests show that simple statistical approach to welding parameters can help in evaluation of weld quality.

  8. Arc spraying solderable tabs to glass

    Science.gov (United States)

    Lindmayer, J.

    1981-01-01

    Tabs suitable for electrical or mechanical connections in solar cells and integrated circuits are made by spraying technique. Solder wets copper, copper bonds to aluminum, and aluminum adheres to glass. Arc spraying is automated and integrated with encapsulation, eliminating hand tabbing, improving reliability, and reducing cost.

  9. ArcAid Interactive Archery Assistant

    Directory of Open Access Journals (Sweden)

    Jeroen Vervaeke

    2015-12-01

    Full Text Available This paper describes the design process of a bow aiming system, called ArcAid, which is an interactive archery assistant. The main goal of ArcAid is to introduce a way for beginner Robin Hoods to learn the art of archery to its fullest. In order to achieve this goal, our smartphone-based design focuses on a fun and interactive learning process that gives constant feedback to the user on how to hit a certain goal. A SPIKE high- end laser sensor is used for the distance measurement and the smartphone’s accelerometer is used to define the angle of inclination. To measure the force on the arrow and the displacement of the string, a flex sensor is attached upon one of the arcs of the bow. All sensor data is processed in an Arduino Nano microprocessor and feedback to the user is given by a dedicated smartphone app. In this paper, we mainly focus on the construction, mechanics and electronics of the ArcAid bow and on the design of the mobile app, which is the game controller. Furthermore, we briefly discuss some future development ideas.

  10. Secondary arc description on satellite solar generators

    OpenAIRE

    Crispel, Pierre; Degond, Pierre; Vignal, Marie-Helene; Roussel, Jean-Francois; Amorim, Emmanuel; Payan, Denis; Cho, Mengu

    2005-01-01

    In this paper, we propose a quasi-neutral model with non-vanishing current describing the expansion of a plasma in an inter-cellular gap on a satellite solar array. Moreover, an electric arc cathode spot model is proposed in order to give suitable boundary conditions for the expansion model.

  11. Nonlinear Study of Industrial Arc Spring Dampers

    DEFF Research Database (Denmark)

    Lahriri, Said; Santos, Ilmar; Hartmann, Henning

    2011-01-01

    The objective of this paper is to present a numerical approach for analyzing parameter excited vibrations on a gas compressor, induced by the nonlinear characteristic of the arc spring feature of certain designs of squeeze film dampers, SFDs. The behavior of the journal is studied in preparation ...

  12. An approach for optimizing arc welding applications

    International Nuclear Information System (INIS)

    The dynamic and transport mechanisms involved in the arc plasma and the weld pool of arc welding operations are numerous and strongly coupled. They produce a medium the magnitudes of which exhibit rapid time variations and very marked gradients which make any experimental analysis complex in this disrupted environment. In this work, we study the TIG and MIG processes. An experimental platform was developed to allow synchronized measurement of various physical quantities associated with welding (process parameters, temperatures, clamping forces, metal transfer, etc.). Numerical libraries dedicated to applied studies in arc welding are developed. They enable the treatment of a large flow of data (signals, images) with a systematic and global method. The advantages of this approach for the enrichment of numerical simulation and arc process control are shown in different situations. Finally, this experimental approach is used in the context of the chosen application to obtain rich measurements to describe the dynamic behavior of the weld pool in P-GMAW. Dimensional analysis of these experimental measurements allows to identify the predominant mechanisms involved and to determine experimentally the characteristic times associated. This type of approach includes better description of the behavior of a macro-drop of molten metal or the phenomena occurring in the humping instabilities. (author)

  13. PyroArc novel Waste-to-energy technology

    International Nuclear Information System (INIS)

    There is a growing interest in using solid waste as a raw material in the production of gas and materials. A new proprietary technology - called PyroArc - utilizes a wide range of waste fractions combined with a reduction of almost the entire volume. The process employs high temperature plasma technology developed by ScanArc. The Norwegian based enterprise, EnviroArc Technologies AS, has the exclusive rights to use PyroArc technology. (author)

  14. Multiple Ionization Of Metal Ions By ECR Heating Of Electrons In Vacuum Arc Plasmas

    Science.gov (United States)

    Vodopyanov, A. V.; Golubev, S. V.; Mansfeld, D. A.; Nikolaev, A. G.; Oks, E. M.; Razin, S. V.; Savkin, K. P.

    2005-03-01

    A joint research and development effort has been initiated, whose ultimate goal is the enhancement the mean ion charge states in vacuum arc metal plasmas by a combination of a vacuum arc discharge and an electron cyclotron resonance (ECR) heating. Metal plasma was generated by a special vacuum arc mini-gun and injected into mirror magnetic trap. Plasma was pumped by high frequency gyrotron-generated microwave radiation (frequency 37.5 GHz, max power 100 kW, pulse duration 1.5 ms). Using of powerful microwaves makes it possible to sustain sufficient temperature of electrons needed for multiple ionizations at high plasma density (more then 1013 cm-3). Parameter of multiple ionization efficiency Neτi, where Ne is plasma density, τi, is ion lifetime, in such a case could reach rather high value ˜109 cm-3-s. In our situation τi = Ltrap/Vi, where Ltrap is trap length, Vi is plasma gun flow velocity. The results have demonstrated substantial multiple ionization of metal ions (including metals with high melting temperature). For a metal (lead, platinum) plasma, ECR heating shifted the average ion charge up to 5+. Further increase of the ion charge states will be attained by increasing the vacuum arc plasma density and optimizing the ECR heating conditions.

  15. Influence of the ionosphere on the altitude of discrete auroral arcs

    Directory of Open Access Journals (Sweden)

    C. S. Deehr

    2005-03-01

    Full Text Available The altitude of the maximum luminosity of single, discrete auroral arcs was measured by photometric triangulation from two stations (College and Fort Yukon, Alaska located 226km apart on nearly the same magnetic meridian. The average height of the evening aurora decreases smoothly with increasing solar depression angle (sda from 160km near 12° sda to 100km after 18° sda. The average height remains constant until around 12° sda in the morning. This diurnal variation is similar to that of the electron density in the F region of the ionosphere. Thus, the behavior is consistent with the concept that the mean auroral electron energy increases as the ionospheric conductivity decreases due to ionospheric recombination in the evening twilight. However, the mean electron energy decreases in magnitude at dawn when the solar ionizing radiation returns and the electron density in the F region increases. The magnetospheric acceleration mechanism associated with discrete auroral arcs thus appears to be inversely proportional to the ionospheric conductivity, because the time variation of the acceleration mechanism coincides with the local F region electron density and not with any obvious magnetospheric process. Previous auroral altitude observations, using similar triangulation methods, showed that the altitude of discrete auroral arcs increases as a function of latitude. When these data are corrected for the twilight effect, the dependence of altitude on latitude disappears. Thus, the average altitude of discrete auroral arcs and, by inference the magnetospheric auroral electron acceleration mechanism, is significantly influenced by the initial ionospheric conductance.

  16. Anatomy of Intra-Oceanic Arc Systems

    Science.gov (United States)

    Stern, R. J.

    2007-12-01

    Intra-oceanic arc systems (IOAS) are ultimately embedded in orogenic belts and added to the continental crust. Reconstructing fossil IOASs in collision zones requires understanding the salient features of a typical IOAS. IOASs have the relative dimensions of tagliatelle (flat) pasta: much wider (~250 km) than thick (10-30 km), much longer (1000's of km) than wide. IOASs begin to form when subduction begins, either spontaneously (SNSZ) or by forced convergence (INSZ). For SNSZ, IOASs start as broad zones of seafloor spreading associated with subsidence of the adjacent lithosphere, whereas INSZ IOASs are built on trapped crust. IOAS magmatism manifests the evolution of its subduction zone and indirectly the breadth of the subducted ocean. Two stages in SNSZ IOAS magmato-tectonic evolution exist: infancy and maturity. Infancy lasts 5-10 Ma and results in broad zones of seafloor spreading of tholeiite/boninite; this becomes forearc for the mature IOAS and is emplaced as ophiolite during collision (subduction zone failure). Arc maturity begins with true subduction, as the subducted slab reaches depths ~130 km, focusing magmatism to begin building the magmatic arc ~200km away from the trench and allowing the forearc to cool and hydrate. Mature magmatic arcs mostly yield low-K tholeiitic and medium-K calc-alkaline magmas. Magmatic focusing begins crustal thickening beneath the magmatic arc, at ~500m/Ma for the Izu-Bonin-Mariana IOAS. No systematic compositional evolution to more LIL-enriched primitive magmas occurs once IOAS maturity is reached, except when upper plate stress regime (BAB formation, strike- slip faulting) or the nature of subducted material (more/different sediments, young oceanic crust) changes. Thickening is accompanied by processing of crust beneath the magmatic arc, with progressive differentiation into upper volcanic, middle tonalitic, and lower mafic layers, producing an increasingly effective density filter for magma ascent. Crustal layer formation

  17. Simulation of the Process of Arc Energy-Effect in High Voltage Auto-Expansion SF6 Circuit Breaker

    Institute of Scientific and Technical Information of China (English)

    Rong Mingzhe; Yang Qian; Fan Chunduo

    2005-01-01

    A new magnetic hydro-dynamics (MHD) model of arc in H.V. auto-expansion SF6circuit breaker that takes into consideration nozzle ablation due to both radiation and thermal conduction is presented in this paper. The effect of PTFE (polytetrafluorethylene) vapor is considered in the mass, momentum and energy conservation equations of the constructed model. Then,the gas flow fields with and without conduction considered are simulated. By comparing the aforementioned two results, it is indicated that the arc's maximal temperature with conduction considered is 90 percent of that without considering conduction.

  18. Bulk arc strain, crustal thickening, magma emplacement, and mass balances in the Mesozoic Sierra Nevada arc

    Science.gov (United States)

    Cao, Wenrong; Paterson, Scott; Saleeby, Jason; Zalunardo, Sean

    2016-03-01

    Quantifying crustal deformation is important for evaluating mass balance, material transfer, and the interplay between tectonism and magmatism in continental arcs. We present a dataset of >650 finite strain analyses compiled from published works and our own studies with associated structural, geochronologic, and geobarometric information in central and southern Sierra Nevada, California, to quantify the arc crust deformation. Our results show that Mesozoic tectonism results in 65% arc-perpendicular bulk crust shortening under a more or less plane strain condition. Mesozoic arc magmatism replaced ∼80% of this actively deforming arc crust with plutons requiring significantly greater crustal thickening. We suggest that by ∼85 Ma, the arc crust thickness was ∼80 km with a 30-km-thick arc root, resulting in a ∼5 km elevation. Most tectonic shortening and magma emplacement must be accommodated by downward displacements of crustal materials into growing crustal roots at the estimated downward transfer rate of 2-13 km/Myr. The downward transfer of crustal materials must occur in active magma channels, or in "escape channels" in between solidified plutons that decrease in size with time and depth resulting in an increase in the intensity of constrictional strain with depth. We argue that both tectonism and magmatism control the thickness of the crust and surface elevation with slight modification by surface erosion. The downward transported crustal materials initially fertilize the MASH zone thus enhancing to the generation of additional magmas. As the crustal root grows it may potentially pinch out and cool the mantle wedge and thus cause reduction of arc magmatism.

  19. Evaluation of the clinical usefulness of modulated Arc treatment

    CERN Document Server

    Lee, Young Kyu; Kim, Yeon Sil; Choi, Byung Ock; Nam, Sang Hee; Park, Hyeong Wook; Kim, Shin Wook; Shin, Hun Joo; Lee, Jae Choon; Kim, Ji Na; Park, Sung Kwang; Kim, Jin Young; Kang, Young-Nam

    2015-01-01

    The purpose of this study is to evaluate the clinical usefulness of modulated arc (mARC) treatment techniques. The mARC treatment plans of the non-small cell lung cancer (NSCLC) patients were performed in order to verify the clinical usefulness of mARC. A pre study was conducted to find the most competent plan condition of mARC treatment and the usefulness of mARC treatment plan was evaluated by comparing it with the other Arc treatment plans such as Tomotherapy and RapidArc. In the case of mARC, the optimal condition for the mARC plan was determined by comparing the dosimetric performance of the mARC plans with the use of various parameters. The various parameters includes the photon energies (6 MV, 10 MV), optimization point angle (6{\\deg}-10{\\deg} intervals), and total segment number (36-59 segment). The best dosimetric performance of mARC was observed at 10 MV photon energy and the point angle 6 degree, and 59 segments. The each treatment plans of three different techniques were compared with the followin...

  20. Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy

    International Nuclear Information System (INIS)

    Purpose: To develop a method for dose reconstruction by incorporating the interplay effect between aperture modulation and target motion, and to assess the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy (VMAT). Methods and Materials: Clinical VMAT plans were delivered with the TrueBeam linac for 8 patients with prostate cancer. The real-time target motion during dose delivery was determined based on the 2-dimensional fiducial localization using an onboard electronic portal imaging device. The target shift in each image was correlated with the control point with the same gantry angle in the VMAT plan. An in-house-developed Monte Carlo simulation tool was used to calculate the 3-dimensional dose distribution for each control point individually, taking into account the corresponding real-time target motion (assuming a nondeformable target with no rotation). The delivered target dose was then estimated by accumulating the dose from all control points in the plan. On the basis of this information, dose–volume histograms and 3-dimensional dose distributions were calculated to assess their degradation from the planned dose caused by target motion. Thirty-two prostate motion trajectories were analyzed. Results: The minimum dose to 0.03 cm3 of the gross tumor volume (D0.03cc) was only slightly degraded after taking motion into account, with a minimum value of 94.1% of the planned dose among all patients and fractions. However, the gross tumor volume receiving prescription dose (V100%) could be largely affected by motion, dropping below 60% in 1 trajectory. We did not observe a correlation between motion magnitude and dose degradation. Conclusions: Prostate motion degrades the delivered dose to the target in an unpredictable way, although its effect is reduced over multiple fractions, and for most patients the degradation is small. Patients with greater prostate motion or those treated with stereotactic body radiation therapy would

  1. TRANSDERMAL DRUG DELIVERY SYSTEM: REVIEW

    OpenAIRE

    Vishvakarama Prabhakar; Agarwal Shivendra; Sharma Ritika; Saurabh Sharma

    2012-01-01

    Various new technologies have been developed for the transdermal delivery of some important drugs. Today about 74% of drugs are taken orally and are found not to be as effective as desired. To improve such characters transdermal drug delivery system was emerged. Drug delivery through the skin to achieve a systemic effect of a drug is commonly known as transdermal drug delivery and differs from traditional topical drug delivery. Transdermal drug delivery systems (TDDS) are dosage forms involve...

  2. The investigation of carbon nitride films prepared at various arc currents by vacuum cathode arc method

    International Nuclear Information System (INIS)

    The carbon nitride films have been prepared in the arc currents range of 20-60 A at the Ar/N2 atmosphere of 50/400 sccm by the vacuum cathode arc deposition method. The properties of the films were characterized by x-ray photoelectron spectroscopy, Raman spectroscopy, Fourier transform infrared spectroscopy and nanoindentation. The N concentration showed a maximum of 35 at% at 20 A and decreased gradually with the arc currents. The films below 40 A consisted of linear polymeric-like component and sp2 graphitic cluster. With the increasing of the arc current from 20 to 40 A, the ID/IG rose and the photoluminescence (PL) fell gradually, which resulted from the development of the sp2 graphitic phase and the decrease of the polymeric-like phase. As a result, the CC bonds increased and sp3CN and sp2CN decreased. Above 40 A, with the increasing of arc currents, ID/IG fell and the PL increased gradually, which reflected the decreasing of sp2 graphitic phase and the modification of C and N atoms in sp2 cluster. The CC bonds and sp3CN fell and the sp2CN rose. The nanohardness of films showed increasing tendency with the arc currents. The variation of the relative ratio and the average energy of N-containing species and C-containing species at the atmosphere would be responsible for the change in the properties of films. (author)

  3. Numerical investigation of the double-arcing phenomenon in a cutting arc torch

    Energy Technology Data Exchange (ETDEWEB)

    Mancinelli, B. R., E-mail: bmancinelli@frvt.utn.edu.ar [Grupo de Descargas Eléctricas, Departamento Ingeniería Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651 (2600) Venado Tuerto, Santa Fe (Argentina); Minotti, F. O.; Kelly, H. [Grupo de Descargas Eléctricas, Departamento Ingeniería Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651 (2600) Venado Tuerto, Santa Fe (Argentina); Instituto de Física del Plasma (CONICET), Departamento de Física, Facultad de Ciencias Exactas y Naturales (UBA) Ciudad Universitaria Pab. I, 1428 Buenos Aires (Argentina); Prevosto, L. [Instituto de Física del Plasma (CONICET), Departamento de Física, Facultad de Ciencias Exactas y Naturales (UBA) Ciudad Universitaria Pab. I, 1428 Buenos Aires (Argentina)

    2014-07-14

    A numerical investigation of the double-arcing phenomenon in a cutting arc torch is reported. The dynamics of the double-arcing were simulated by using a two-dimensional model of the gas breakdown development in the space-charge layer contiguous to the nozzle of a cutting arc torch operated with oxygen. The kinetic scheme includes ionization of heavy particles by electron impact, electron attachment, electron detachment, electron–ion recombination, and ion–ion recombination. Complementary measurements during double-arcing phenomena were also conducted. A marked rise of the nozzle voltage was found. The numerical results showed that the dynamics of a cathode spot at the exit of the nozzle inner surface play a key role in the raising of the nozzle voltage, which in turn allows more electrons to return to the wall at the nozzle inlet. The return flow of electrons thus closes the current loop of the double-arcing. The increase in the (floating) nozzle voltage is due to the fact that the increased electron emission at the spot is mainly compensated by the displacement current (the ions do not play a relevant role due to its low-mobility) until that the stationary state is achieved and the electron return flow fully-compensates the electron emission at the spot. A fairly good agreement was found between the model and the experiment for a spot emission current growth rate of the order of 7 × 10{sup 4} A/s.

  4. arcControlTower, the System for Atlas Production and Analysis on ARC

    CERN Document Server

    Filipcic, A; The ATLAS collaboration

    2010-01-01

    Abstract content Panda, the Atlas management and distribution system for production and analysis jobs on EGEE and OSG clusters, is based on pilot jobs to increase the throughput and stability of the job execution on grid. The ARC middleware uses specific approach which tightly connects the job requirements with cluster capabilities like resource usage, software availability and caching of input files. The pilot concept renders the ARC features useless. The arcControlTower is the job submission system which merges the pilot benefits and ARC advantages. It takes the pilot payload from the panda server and submits the jobs to the Nordugrid ARC clusters as regular jobs, with all the resources known in advance. All the pilot communication with the panda server is done by the arcControlTower, so it plays the role of a pilot factory and the pilot itself. There are several advantages to this approach: no grid middleware is needed on the worker nodes, the fair-share between the production and user jobs is tuned with t...

  5. Dosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcsDosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcs.

    Science.gov (United States)

    Liu, Haisong; Li, Jun; Pappas, Evangelos; Andrews, David; Evans, James; Werner-Wasik, Maria; Yu, Yan; Dicker, Adam; Shi, Wenyin

    2016-01-01

    An automatic brain-metastases planning (ABMP) software has been installed in our institution. It is dedicated for treating multiple brain metastases with radiosurgery on linear accelerators (linacs) using a single-setup isocenter with noncoplanar dynamic conformal arcs. This study is to validate the calculated absolute dose and dose distribution of ABMP. Three types of measurements were performed to validate the planning software: 1, dual micro ion chambers were used with an acrylic phantom to measure the absolute dose; 2, a 3D cylindrical phantom with dual diode array was used to evaluate 2D dose distribution and point dose for smaller targets; and 3, a 3D pseudo-in vivo patient-specific phantom filled with polymer gels was used to evaluate the accuracy of 3D dose distribution and radia-tion delivery. Micro chamber measurement of two targets (volumes of 1.2 cc and 0.9 cc, respectively) showed that the percentage differences of the absolute dose at both targets were less than 1%. Averaged GI passing rate of five different plans measured with the diode array phantom was above 98%, using criteria of 3% dose difference, 1 mm distance to agreement (DTA), and 10% low-dose threshold. 3D gel phantom measurement results demonstrated a 3D displacement of nine targets of 0.7 ± 0.4 mm (range 0.2 ~ 1.1 mm). The averaged two-dimensional (2D) GI passing rate for several region of interests (ROI) on axial slices that encompass each one of the nine targets was above 98% (5% dose difference, 2 mm DTA, and 10% low-dose threshold). Measured D95, the minimum dose that covers 95% of the target volume, of the nine targets was 0.7% less than the calculated D95. Three different types of dosimetric verification methods were used and proved the dose calculation of the new automatic brain metastases planning (ABMP) software was clinical acceptable. The 3D pseudo-in vivo patient-specific gel phantom test also served as an end-to-end test for validating not only the dose calculation, but the

  6. Global Delivery Models

    DEFF Research Database (Denmark)

    Manning, Stephan; Møller Larsen, Marcus; Bharati, Pratyush

    We investigate antecedents and contingencies of location configurations supporting global delivery models (GDMs) in global outsourcing. GDMs are a new form of IT-enabled client-specific investment promoting services provision integration with clients by exploiting client proximity and time......-zone spread allowing for 24/7 service delivery and access to resources. Based on comprehensive data we show that providers are likely to establish GDM configurations when clients value access to globally distributed talent pools and speed of service delivery, and in particular when services are highly...

  7. Global Delivery Models

    DEFF Research Database (Denmark)

    Manning, Stephan; Larsen, Marcus M.; Bharati, Pratyush

    2013-01-01

    This article examines antecedents and performance implications of global delivery models (GDMs) in global business services. GDMs require geographically distributed operations to exploit both proximity to clients and time-zone spread for efficient service delivery. We propose and empirically show...... that service providers who differentiate based on speed of service delivery are likely to set up GDM structures, and that these structures positively affect deal renewal rates if speed is important for clients in selecting vendors. Findings imply that, as co-location becomes less necessary for providing...... digitalized services, time zones increasingly affect....

  8. THE PERIODIC CAPACITATED ARC ROUTING PROBLEM LINEAR PROGRAMMING MODEL,METAHEURISTIC AND LOWER BOUNDS

    Institute of Scientific and Technical Information of China (English)

    Feng CHU; Nacima LABADI; Christian PRINS

    2004-01-01

    The Periodic Capacitated Arc Routing Problem (PCARP) generalizes the well known NP-hard Capacitated Arc Routing Problem (CARP) by extending the single period to multi-period horizon.The Capacitated Arc Routing Problem (CARP) is defined on an undirected network in which a fleet of identical vehicles is based at a depot node. A subset of edges, called tasks, must be serviced by a vehicle. The CARP consists of determining a set of feasible vehicle trips that minimizes the total cost of traversed edges. The PCARP involves the assignment of tasks to periods and the determination of vehicles trips in each period, to minimize the total cost on the whole horizon. This new problem arises in various real life applications such as waste collection, mail delivery, etc. In this paper, a new linear programming model and preliminary lower bounds based on graph transformation are proposed. A meta-heuristic approach - Scatter Search (SS) is developed for the PCARP and evaluated on a large variety of instances.

  9. Detecting stellar-wind bubbles through infrared arcs in HII regions

    CERN Document Server

    Mackey, Jonathan; Gvaramadze, Vasilii V; Mohamed, Shazrene; Langer, Norbert; Harries, Tim J

    2015-01-01

    Mid-infrared arcs of dust emission are often seen near ionizing stars within HII regions. A possible explanations for these arcs is that they could show the outer edges of asymmetric stellar wind bubbles. We use two-dimensional, radiation-hydrodynamics simulations of wind bubbles within HII regions around individual stars to predict the infrared emission properties of the dust within the HII region. We assume that dust and gas are dynamically well-coupled and that dust properties (composition, size distribution) are the same in the HII region as outside it, and that the wind bubble contains no dust. We post-process the simulations to make synthetic intensity maps at infrared wavebands using the TORUS code. We find that the outer edge of a wind bubble emits brightly at 24um through starlight absorbed by dust grains and re-radiated thermally in the infrared. This produces a bright arc of emission for slowly moving stars that have asymmetric wind bubbles, even for cases where there is no bow shock or any corresp...

  10. Driven Motion and Instability of an Atmospheric Pressure Arc

    Energy Technology Data Exchange (ETDEWEB)

    Max Karasik

    1999-12-01

    Atmospheric pressure arcs are used extensively in applications such as welding and metallurgy. However, comparatively little is known of the physics of such arcs in external magnetic fields and the mechanisms of the instabilities present. In order to address questions of equilibrium and stability of such arcs, an experimental arc furnace is constructed and operated in air with graphite cathode and steel anode at currents 100-250 A. The arc is diagnosed with a gated intensified camera and a collimated photodiode array, as well as fast voltage and current probes.

  11. Driven Motion and Instability of an Atmospheric Pressure Arc

    International Nuclear Information System (INIS)

    Atmospheric pressure arcs are used extensively in applications such as welding and metallurgy. However, comparatively little is known of the physics of such arcs in external magnetic fields and the mechanisms of the instabilities present. In order to address questions of equilibrium and stability of such arcs, an experimental arc furnace is constructed and operated in air with graphite cathode and steel anode at currents 100-250 A. The arc is diagnosed with a gated intensified camera and a collimated photodiode array, as well as fast voltage and current probes

  12. Intensity-Modulated Arc Therapy for Pediatric Posterior Fossa Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Beltran, Chris, E-mail: chris.beltran@stjude.org [Department of Radiological Sciences, St. Jude Children' s Research Hospital, Memphis, TN (United States); Gray, Jonathan; Merchant, Thomas E. [Department of Radiological Sciences, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2012-02-01

    Purpose: To compare intensity-modulated arc therapy (IMAT) to noncoplanar intensity-modulated radiation therapy (IMRT) in the treatment of pediatric posterior fossa tumors. Methods and Materials: Nine pediatric patients with posterior fossa tumors, mean age 9 years (range, 6-15 years), treated using IMRT were chosen for this comparative planning study because of their tumor location. Each patient's treatment was replanned to receive 54 Gy to the planning target volume (PTV) using five different methods: eight-field noncoplanar IMRT, single coplanar IMAT, double coplanar IMAT, single noncoplanar IMAT, and double noncoplanar IMAT. For each method, the dose to 95% of the PTV was held constant, and the doses to surrounding critical structures were minimized. The different plans were compared based on conformity, total linear accelerator dose monitor units, and dose to surrounding normal tissues, including the entire body, whole brain, temporal lobes, brainstem, and cochleae. Results: The doses to the target and critical structures for the various IMAT methods were not statistically different in comparison with the noncoplanar IMRT plan, with the following exceptions: the cochlear doses were higher and whole brain dose was lower for coplanar IMAT plans; the cochleae and temporal lobe doses were lower and conformity increased for noncoplanar IMAT plans. The advantage of the noncoplanar IMAT plan was enhanced by doubling the treatment arc. Conclusion: Noncoplanar IMAT results in superior treatment plans when compared to noncoplanar IMRT for the treatment of posterior fossa tumors. IMAT should be considered alongside IMRT when treatment of this site is indicated.

  13. Integrated primary flight display: the sky arc

    Science.gov (United States)

    Voulgaris, Theodore J.; Metalis, Sam A.; Mobley, R. S.

    1995-05-01

    Flight instrument interpretability has been a key piloting issue because it is directly related to operator performance and inversely related to operator error. To improve interpretability we have developed the Sky Arc, a new symbology initially developed for attitude control, particularly for a helmet-mounted display. It consists of an integrated set of graphic symbols which vary in a continuous, analog fashion with changing flight parameters. The Sky Arc currently integrates, pitch, roll, heading, air speed, and terrain avoidance. The display can be integrated into a head down display, a head up display, or a helmet mounted display. In this preliminary study the usability of the Sky Arc as an attitude indicator was compared to a conventional head-up display pitch ladder symbology. The test involved six test subject pilots and a medium-fidelity simulator. The pilots were asked to fully recover from a series of unusual attitude conditions that were presented on the simulator. The time taken to recover and the correctness of the recovery procedure served as the objective evaluation measures. A Likert-type rating scale and open-ended subject matter expert opinions served as the subjective measures of evaluation. To examine whether there was a relationship between usability of the attitude indicator and difficulty of the unusual attitude, the workload levels involved in performing the unusual attitude recoveries were grouped into three levels, low, medium, and high. At each workload level there were four conditions, for a total of 12 different conditions. Each pilot was asked to recovery twice from each condition, for a total of 24 unusual attitude recovery trials. The test trials were counterbalanced and displayed in a prearranged order. No differences due to difficulty of the unusual attitude were detected. Overall, the study revealed that the Sky Arc led to generally faster recoveries than did the standard display, as well as higher subjective preference ratings

  14. Quasi-VMAT in high-grade glioma radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fadda, G.; Massazza, G.; Zucca, S.; Durzu, S.; Meleddu, G.; Possanzini, M.; Farace, P. [Regional Oncological Hospital, Cagliari (Italy). Dept. of Radio-Oncology

    2013-05-15

    Purpose: To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession. Patients and methods: This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2-3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1-3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose < 54 Gy) for a virtual OAR in the form of a 0.5 cm ring around the PTV was investigated. Results: The qVMAT method gave rise to significantly improved PTV{sub 95%} and conformity index (CI) values in comparison to 3D-CRT (PTV{sub 95%} = 90.7 % vs. 82.0 %; CI = 0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV{sub 95%} = 94.4 %, CI = 0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV{sub 95%} = 88.5 % and 92.3 %, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT. Conclusion: These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example

  15. Quasi-VMAT in high-grade glioma radiation therapy

    International Nuclear Information System (INIS)

    Purpose: To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession. Patients and methods: This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2-3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1-3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose 95% and conformity index (CI) values in comparison to 3D-CRT (PTV95% = 90.7 % vs. 82.0 %; CI = 0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV95% = 94.4 %, CI = 0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV95% = 88.5 % and 92.3 %, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT. Conclusion: These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example, which have limited departmental resources and are not equipped with systems capable of VMAT delivery. (orig.)

  16. Project Delivery Methods.

    Science.gov (United States)

    Dolan, Thomas G.

    2003-01-01

    Describes project delivery methods that are replacing the traditional Design/Bid/Build linear approach to the management, design, and construction of new facilities. These variations can enhance construction management and teamwork. (SLD)

  17. BASIC THEORY AND APPLICATIONS OF WELDING ARC SPECTRAL INFORMATION

    Institute of Scientific and Technical Information of China (English)

    LI Junyue; XUE Haitao; LI Huan; SONG Yonglun

    2007-01-01

    Welding arc spectral information is a rising welding Information source. In some occasion, it can reflect many physical phenomena of welding process and solve many problems that cannot be done with arc electric information, acoustic information and other arc information. It is of important significance in developing automatic control technique of welding process and other similar process. Many years study work on welding arc spectral information of the anthor are discussed from three aspects of theory, method and application. Basic theory, view and testing methods of welding arc spectral information has been put forward. In application aspects, many applied examples, for example, monitoring of harmful gases in arc (such as hydrogen and nitrogen) with the method of welding arc spectral information; welding arc spectral imaging of thc welding pool which is used in automatic seam tracking; controlling of welding droplet transfer with welding arc spectral information and so on, are introduced. Especially, the successful application in real time controlling of welding droplet transfer in pulsed GMAW is introduced too. These application examples show that the welding arc spectral information has great applied significance and development potentialities. These content will play an important role in applying and spreading welding arc spectral information technology.

  18. Series and parallel arc-fault circuit interrupter tests.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean; Fresquez, Armando J.; Gudgel, Bob; Meares, Andrew

    2013-07-01

    While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by opening the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.

  19. Dual Torch Plasma Arc Furnace for Medical Waste Treatment

    Institute of Scientific and Technical Information of China (English)

    LIU Bin; M.KIKUCHI; LI Heping; T.IWAO; T.INABA

    2007-01-01

    In this paper,characteristics of a dual torch plasma arc used for hazardous waste treatment and operated at atmospheric pressure are studied,and also compared with those of the multi-torch plasma arc and the single torch plasma arc.The dual torch plasma arc is generated between the cathode and anode with argon as the working gas.The temperature distributions of the plasma arc are measured using a spectroscope and line pair method with the assumption of local thermodynamic equilibrium (LTE) for the DC arc current I = 100 A and argon flow rate Q = 15 slpm.The measurements show that the temperatures of the dual torch arc plasma in the regions near the cathode,the anode and the center point are 10,000 K,11,000 K and 9,000 K,respectively.And the high temperature region of the multi torch plasma arc is of double or much wider size than that of a conventional dual torch plasma arc and single plasma torch.Based on the preceding studies,a dual torch plasma arc furnace is developed in this study.The measured gas temperature at the center region of the argon arc is about 11,000 K for the case of I = 200 A and Q = 30 slpm operated in atmosphere.

  20. NTWV-based sensing keyhole dimension in plasma arc welding

    Institute of Scientific and Technical Information of China (English)

    Jia Chuanbao; Wu Chuansong; Zhang Yuming

    2008-01-01

    During stable keyhole plasma arc welding, the pilot arc and the transferred arc exist at the meantime, and the arcs can be considered as a composition of two parts inside and outside the nozzle, respectively. Under the mechanical constriction and thermal contraction effects, the inside arc has certain arc length, electron density and arc profile etc. Inducing constant tungsten-to-nozzle voltage. However, the arc outside the nozzle diverges at about 5 degrees and has certain characteristics similar to the free arcs. The nozzle-to-workpiece voltage (NTWV) depends mainly on the length of the arc, which gets bigger as increasing of the weld penetration and keyhole size. The NTWV sensor is developed for monitoring NTWV in real time. The welding experiments are designed to get different penetrations and keyhole sizes. It is found that as the weld penetration and the keyhole size increase, NTWV also increases linearly. The NTWV signals can be used as the feedback variable in automatic control of keyhole plasma arc welding.

  1. Discharge Characteristics of DC Arc Water Plasma for Environmental Applications

    Institute of Scientific and Technical Information of China (English)

    LI Tianming; Sooseok CHOI; Takayuki WATANABE

    2012-01-01

    A water plasma was generated by DC arc discharge with a hafnium embedded rodtype cathode and a nozzle-type anode. The discharge characteristics were examined by changing the operation parameter of the arc current. The dynamic behavior of the arc discharge led to significant fluctuations in the arc voltage and its frequency. Analyses of the high speed image and the arc voltage waveform showed that the arc discharge was in the restrike mode and its frequency varied within several tens of kilohertz according to the operating conditions. The larger thermal plasma volume was generated by the higher flow from the forming steam with a higher restrike frequency in the higher arc current conditions. In addition, the characteristics of the water plasma jet were investigated by means of optical emission spectroscopy to identify the abundant radicals required in an efficient waste treatment process.

  2. Radiation enteritis

    Science.gov (United States)

    ... enteropathy; Radiation-induced small bowel injury; Post-radiation enteritis ... often are no good treatments for chronic radiation enteritis that is more severe. Medicines such as cholestyramine, ...

  3. [Transdermal Delivery of NSAIDs].

    Science.gov (United States)

    Nakajima, Takehisa; Makino, Kimiko

    2015-11-01

    Skin has been studied as administration site of drug for its systemic effects, since systemic therapeutic agents can be delivered for long time with a controlled ratio, escaping from the first pass effect by liver by the transdermal delivery, which can decrease the dosage form. The low permeability of drug molecules through stratum corneum has been the limiting factor for developing transdermal delivery system of therapeutic agents. To enhance the permeability of drug molecules, many studies have been reported. PMID:26689064

  4. Comparative study of dosimetry between volumetric-modulated arc therapy and intensity-modulated radiation therapy for brain metastases%多发脑转移癌容积弧形调强与适形调强的剂量学对比研究

    Institute of Scientific and Technical Information of China (English)

    龙斌; 谢悦; 蒋勇; 李淑杰; 邱大; 王颖

    2015-01-01

    Objective To compare volumetric‐modulated arc therapy(VMAT) with intensity‐modulated radiation therapy (IMRT) for brain metastases with regard to the dosimetric character .Methods Sixty patients who were diagnosed with brain me‐tastases were included in this study .The target area received two dose levels using late addition amount technique ,WBRT (30 Gy/10 F) with following addition (20 Gy/10 F) to 59 Gy .For a fair comparison ,VMAT and IMRT treatment plans were respectively designed for every patient with the same dosimetric constraints .Dosimetric comparisons between VMAT and IMRT plans were ana‐lyzed to evaluate :target coverage and homogeneity ,conformity of PTV ;sparing of OARs ;monitor units (MUs) .Results Two treatment plans all reached the treatment need .When compared with IMRT ,there was no significant difference in Dmean of eyeball , len ,optic never ,visual chiasma ,parotid ,brain stem ,and external auditory canal of VMAT (P>0 .05) .The Dmax of eyeball ,len ,pa‐rotid ,and external auditory canal of VMAT were lower than that in IMRT group (P<0 .05) .The VMAT group has the less MUs (P=0 .017) and less treatment time .Conclusion VMAT can reach the big‐dose radiotherapy need on brain metastases clinically . There are no significant diffference between VMAT and IMRT on Dmax ,Dmean ,CI ,and HI .The Dmax of eyeball ,len ,parotid ,and external auditory canal of VMAT were lower than that in IMRT group .The VMAT can reduce the radiotherapy time .%目的:探讨多发脑转移癌在治疗中容积弧形调强放疗(VMAT)与适形调强放疗(IMRT)的剂量学特点。方法选择60例确诊的多发脑转移癌患者纳入本研究。所有患者均采用全脑放疗加肿瘤靶区后期加量技术给予处方剂量,全脑放疗30 Gy/10F ,病灶加量20 Gy/10F至生物学剂量59 Gy。每例患者采用同样的剂量学条件限制,分别进行两弧容积弧形调强计划与调强计划设计。通过其剂量学分析评估:

  5. CAUDAL BRAINSTEM DELIVERY OF GHRELIN INDUCES FOS EXPRESSION IN THE NUCLEUS OF THE SOLITARY TRACT, BUT NOT IN THE ARCUATE OR PARAVENTRICULAR NUCLEI OF THE HYPOTHALAMUS

    OpenAIRE

    Faulconbridge, Lucy F.; Grill, Harvey J.; Kaplan, Joel M.; Daniels, Derek

    2008-01-01

    Ghrelin increases food intake when injected into either the forebrain or hindbrain ventricles. Brain areas activated by ghrelin after forebrain delivery have been examined using Fos immunohistochemistry and include the hypothalamic arcuate (Arc) and paraventricular (PVN) nuclei, and the nucleus of the solitary tract (NTS) in the medulla. It is not clear, however, if ghrelin applied directly to the hindbrain activates forebrain structures. Therefore, we examined Fos expression in the Arc, PVN,...

  6. Numerical modeling of transferred arc melting bath heating; Modelisation numerique du chauffage de bains par arc transfere

    Energy Technology Data Exchange (ETDEWEB)

    Bouvier, A. [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches; Trenty, L.; Guillot, J.B. [Ecole Centrale de Paris, Laboratoire EM2C. CNRS, 92 - Chatenay-Malabry (France); Delalondre, C. [Electricite de France (EDF), 78 - Chatou (France). Direction des Etudes et Recherches

    1997-12-31

    This paper presents the modeling of a transferred electric arc inside a bath of melted metal. After a recall of the context of the study, the problem of the modeling, which involves magnetohydrodynamic coupling inside the arc and the bath, is described. The equations that govern the phenomena inside the arc and the bath are recalled and the approach used for the modeling of the anode region of the arc is explained using a 1-D sub-model. The conditions of connection between arc and bath calculations are explained and calculation results obtained with a 200 kW laboratory furnace geometry are presented. (J.S.) 8 refs.

  7. Review on the characteristics of radiation detectors for dosimetry and imaging

    Science.gov (United States)

    Seco, Joao; Clasie, Ben; Partridge, Mike

    2014-10-01

    The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been transformed by the implementation of multi-slice CT and digital x-ray imaging systems, with silver halide films now largely obsolete for many applications. Nuclear medicine has benefited from more sensitive, faster and higher-resolution detectors delivering ever-higher SPECT and PET image quality. PET/MR systems have been enabled by the development of gamma ray detectors that can operate in high magnetic fields. These huge advances in imaging have enabled equally impressive steps forward in radiotherapy delivery accuracy, with 4DCT, PET and MRI routinely used in treatment planning and online image guidance provided by cone-beam CT. The challenge of ensuring safe, accurate and precise delivery of highly complex radiation fields has also both driven and benefited from advances in radiation detectors. Detector systems have been developed for the measurement of electron, intensity-modulated and modulated arc x-ray, proton and ion beams, and around brachytherapy sources based on a very wide range of technologies. The types of measurement performed are equally wide, encompassing commissioning and quality assurance, reference dosimetry, in vivo dosimetry and personal and environmental monitoring. In this article, we briefly introduce the general physical characteristics and properties that are commonly used to describe the behaviour and performance of both discrete and imaging detectors. The physical principles of operation of calorimeters; ionization and charge detectors; semiconductor, luminescent, scintillating and chemical detectors; and radiochromic and radiographic films are then reviewed and their principle applications discussed. Finally, a general

  8. Media effects on nanobrass arc fabrications

    International Nuclear Information System (INIS)

    Brass rods (3 mm x 30 mm) are directly converted into brass nanoparticles through a modified arc method, at 100 A, and in five different media. The X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDX), and scanning electron microscopy (SEM) data show strong dependence of nanoparticle sizes and their compositions on the media employed. In distilled water, both nanobrass (30 nm) and nano-Cu/ZnO (18 nm) are produced in comparable quantities. In gaseous nitrogen merely nanobrass (49 nm) is observed, in a high yield. In contrast, a very low yield of nanoproduct(s) is encountered in liquid nitrogen. In the open air, nanobrass (75 nm) is formed along with traces of ZnO. In ethylene glycol, nanobrass (108 nm) is formed as the major product along with a nanoalloy of CuZn5 (25 nm). Among these, distilled water proved to be the medium of choice for the arc synthesis of nanobrass

  9. The singing arc: the oldest memristor?

    CERN Document Server

    Ginoux, Jean-Marc

    2014-01-01

    On April 30th 2008, the journal Nature announced that the missing circuit element, postulated thirty-seven years before by Professor Leon O. Chua has been found. Thus, after the capacitor, the resistor and the inductor, the existence of a fourth fundamental element of electronic circuits called "memristor" was established. In order to point out the importance of such a discovery, the aim of this article is first to propose an overview of the manner with which the three others have been invented during the past centuries. Then, a comparison between the main properties of the singing arc, i.e. a forerunner device of the triode used in Wireless Telegraphy, and that of the memristor will enable to state that the singing arc could be considered as the oldest memristor.

  10. Submerged arc welding of heavy plate

    Science.gov (United States)

    Wilson, R. A.

    1972-01-01

    The submerged arc process is particularly suitable for heavy plate welding because of its ability to combine very high deposit rates along with excellent quality. It does these things without the smoke and spatter often accompanying other processes. It is available today in several forms that are pointed to the fabricators of heavy sections with long, short or round about welds. Tandem arc full automatic equipment is particularly suitable for those long heavy welds where speed and deposit rate are of the first order. An attachment called long stick-out which makes use of the IR drop on long electrode extensions can be included on this equipment to increase deposition rates 50% or more.

  11. Passive Visual Sensing in Automatic Arc Welding

    DEFF Research Database (Denmark)

    Liu, Jinchao

    the interference of the extremely strong arc light and controlling the exposure time of the camera on the y to capture dierent images for seam tracking and weld pool sensing. From the software side, we have designed a passive seam detection algorithm based on robust estimation techniques which can detect the seam......-circuit moment. The essence is that deformable models can be immune to spurious edges caused by strong arc light and/or re ection from the seam by incorporating prior information on regions and boundaries. The main ndings are organized and presented in this dissertation....... industrial solutions for seam detection such as using laser scanners suer from several limitations. For instance, it must be positioned some distance ahead to the molten pool and may cause problem when dealing with shiny surfaces. Existing techniques for weld pool sensing mostly rely on auxiliary light...

  12. A pulsed cathodic arc spacecraft propulsion system

    Science.gov (United States)

    Neumann, P. R. C.; Bilek, M. M. M.; Tarrant, R. N.; McKenzie, D. R.

    2009-11-01

    We investigate the use of a centre-triggered cathodic arc as a spacecraft propulsion system that uses an inert solid as a source of plasma. The cathodic vacuum arc produces almost fully ionized plasma with a high exhaust velocity (>104 m s-1), giving a specific impulse competitive with other plasma or ion thrusters. A centre trigger design is employed that enables efficient use of cathode material and a high pulse-to-pulse repeatability. We compare three anode geometries, two pulse current profiles and two pulse durations for their effects on impulse generation, energy and cathode material usage efficiency. Impulse measurement is achieved through the use of a free-swinging pendulum target constructed from a polymer material. Measurements show that impulse is accurately controlled by varying cathode current. The cylindrical anode gave the highest energy efficiency. Cathode usage is optimized by choosing a sawtooth current profile. There is no requirement for an exhaust charge neutralization system.

  13. Semitransparent curtains for control of optical radiation hazards

    Science.gov (United States)

    Sliney, D. H.; Moss, C. E.; Miller, C. G.; Stephens, J. B.

    1981-01-01

    The purposes and functions of semitransparent eye protective curtains are analyzed. Based upon this analysis, functional requirements are developed, and design requirements are specified for optimum curtains to be used with open arc welding and arc cutting processes. Such curtains also protect against other high intensity broad-spectral-band sources such as compact arc lamps. The requirements for filtering out hazardous UV radiation and blue light must be balanced against the need for transparency in the visible spectrum and the need for reduced glare. Infrared attenuation is shown to be of very little importance.

  14. Double plasma arc in a graphite tube - application of discharge atmospheres

    International Nuclear Information System (INIS)

    With a view to safety and economic efficiency element-specific limits are required for permissible impurities in reactor graphite. This leads to the necessity of developing suitable methods of analysis. Emission spectroscopy has proved to be a method of analysis featuring a high detection capability and offering the possibility of determining several elements simultaneously. A prolongation of the particle residence time in the plasma (and, thus, an increase in radiation intensity) was the objective when developing a novel spectrochemical source of excitation. The method uses two d.c. arcs burning in a horizontally arranged graphite tube. The double plasma arc in a graphite tube has proved to be an excellent source of excitation for the analysis of powder and solutions. (orig./IHOE)

  15. Volumetric modulated arc therapy for carotid sparing in the management of early glottic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Suk; Lee, Sol Min; Kim, Gwi Eon [Dept. of Radiation Oncology, Jeju National University Hospital, Jeju National University School of Medicine, Jeju (Korea, Republic of); Lee, Jae Gi; Park, Jong In; Sung, Won Mo [Program in Biomedical Radiation Sciences, Dept. of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of)

    2016-03-15

    Radiotherapy of the neck is known to cause carotid artery stenosis. We compared the carotid artery dose received between volumetric modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (IMRT) plans in patients with early glottic cancer. Twenty-one early glottic cancer patients who previously underwent definitive radiotherapy were selected for this study. For each patient, double arc VMAT, 8-field IMRT, 3-dimensional conformal radiotherapy (3DCRT), and lateral parallel-opposed photon field radiotherapy (LPRT) plans were created. The 3DCRT plan was generated using lateral parallel-opposed photon fields plus an anterior photon field. VMAT and IMRT treatment plan optimization was performed under standardized conditions to obtain adequate target volume coverage and spare the carotid artery. Dose-volume specifications for the VMAT, IMRT, 3DCRT, and LPRT plans were calculated with radiotherapy planning system. Monitor units (MUs) and delivery time were measured to evaluate treatment efficiency. Target volume coverage and homogeneity results were comparable between VMAT and IMRT; however, VMAT was superior to IMRT for carotid artery dose sparing. The mean dose to the carotid arteries in double arc VMAT was reduced by 6.8% compared to fixed-field IMRT (p < 0.001). The MUs for VMAT and IMRT were not significantly different (p = 0.089). VMAT allowed an approximately two-fold reduction in treatment delivery time in comparison to IMRT (3 to 5 minutes vs. 5 to 10 minutes). VMAT resulted in a lower carotid artery dose compared to conventional fixed-field IMRT, and maintained good target coverage in patients with early glottic cancer.

  16. Arc inhibitors for lower hybrid waveguide arrays

    International Nuclear Information System (INIS)

    The discontinuity at the mouth of a phased array between waveguide fields and plasma fields gives rise to strong, localized electric fields at the septa, especially if the array is excited asymetrically. Methods are suggested for modifying these fields to reduce the possibility of arcing. Probe measurements of the fields near the septa show that small but significant reductions of the local fields are possible and might raise the maximum power handling capability of an array

  17. Adaptive Gas Metal Arc (GMA) Welder

    Science.gov (United States)

    Nachev, G.; Petkov, B.; Blagoev, L.; Tsankarski, I.

    1984-02-01

    Unlike NC machine-tools, where the tool path is primary and the product shape results from it, in arc welding the product is primary, and the welder - human or robot - has to contend with poor fitups, bad preparations, inexact positionning etc. All this means one thing - adaptivity. The axtent to which this is reasonable is discussed, and then a research project, conducted at IICR with the aim to create an adaptive GMA robot, is presented.

  18. HPF Implementation of ARC3D

    Science.gov (United States)

    Frumkin, Michael; Yan, Jerry

    1999-01-01

    We present an HPF (High Performance Fortran) implementation of ARC3D code along with the profiling and performance data on SGI Origin 2000. Advantages and limitations of HPF as a parallel programming language for CFD applications are discussed. For achieving good performance results we used the data distributions optimized for implementation of implicit and explicit operators of the solver and boundary conditions. We compare the results with MPI and directive based implementations.

  19. Multi-colour detection of gravitational arcs

    Science.gov (United States)

    Maturi, Matteo; Mizera, Sebastian; Seidel, Gregor

    2014-07-01

    Strong gravitational lensing provides fundamental insights into the understanding of the dark matter distribution in massive galaxies, galaxy clusters, and the background cosmology. Despite their importance, few gravitational arcs have been discovered so far. The urge for more complete, large samples and unbiased methods of selecting candidates increases. Several methods for the automatic detection of arcs have been proposed in the literature, but large amounts of spurious detections retrieved by these methods force observers to visually inspect thousands of candidates per square degree to clean the samples. This approach is largely subjective and requires a huge amount of checking by eye, especially considering the actual and upcoming wide-field surveys, which will cover thousands of square degrees. In this paper we study the statistical properties of the colours of gravitational arcs detected in the 37 deg2 of the CFHTLS-Archive-Research Survey (CARS). Most of them lie in a relatively small region of the (g' - r', r' - i') colour-colour diagram. To explain this property, we provide a model that includes the lensing optical depth expected in a ΛCDM cosmology that, in combination with the sources' redshift distribution of a given survey, in our case CARS, peaks for sources at redshift z ~ 1. By furthermore modelling the colours derived from the spectral energy distribution of the galaxies that dominate the population at that redshift, the model reproduces the observed colours well. By taking advantage of the colour selection suggested by both data and model, we automatically detected 24 objects out of 90 detected by eye checking. Compared with the single-band arcfinder, this multi-band filtering returns a sample complete to 83% and a contamination reduced by a factor of ~6.5. New gravitational arc candidates are also proposed.

  20. Maintaining Arc Consistency with Multiple Residues

    OpenAIRE

    Lecoutre, Christophe; Likitvivatanavong, Chavalit; Shannon, Scott; Yap, Roland; Zhang, Yuanlin

    2008-01-01

    International audience Exploiting residual supports (or residues) has proved to be one of the most cost-effective approaches for Maintaining Arc Consistency during search (MAC). While MAC based on optimal AC algorithm may have better theoretical time complexity in some cases, in practice the overhead for maintaining required data structure during search outweighs the benefit, not to mention themore complicated implementation. Implementing MAC with residues, on the other hand, is trivial. I...

  1. Obtaining Solutions to Radiation-And Plasma Induced FAilure Modes From Physics

    Science.gov (United States)

    Frederickson, A.

    1998-01-01

    A number of performance-limiting spacecraft problems will be qualitatively discussed: Spacecraft Charging, Deep Dielectric Charging, Solar Cell Arcing, Antenna Sparking, High Voltage Power Shorts, Radiation-induced Defects in Semiconductors, and Degradation of Electronic Devices.

  2. SU-E-T-538: Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, R; Zhan, L; Osei, E [Grand River Hospital, Kitchener, ON (Canada)

    2015-06-15

    Purpose: Dose distributions of RapidArc Plan can be quite different from standard 3D conformal radiation therapy. SBRT plans can be optimized with high conformity or mimic the 3D conformal treatment planning with very high dose in the center of the tumor. This study quantifies the dosimetric differences among 3D conformal plan; flattened beam and FFF beam RapidArc Plans for lung SBRT. Methods: Five lung cancer patients treated with 3D non-coplanar SBRT were randomly selected. All the patients were CT scanned with 4DCT to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. The prescription dose was 48 Gy in 4 fractions. The PTV coverage was optimized by two groups of objective function: one with high conformity, another mimicking 3D conformal dose distribution with high dose in the center of PTV. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using four full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. Results: All the RapidArc plans with flattened beam and FFF beam had similar results for the PTV and OARs. For the high conformity optimization group, The DVH of PTV exhibited a steep dose fall-off outside the PTV compared to the 3D non-coplanar plan. However, for the group mimicking the 3D conformal target dose distribution, although the PTV is very similar to the 3D conformal plan, the ITV coverage is better than 3D conformal plan. Conclusion: Due to excellent clinical experiences of 3D conformal SBRT treatment, the Rapid Arc optimization mimicking 3D conformal planning may be suggested for clinical use.

  3. Spiraling Fermi arcs in Weyl materials

    Science.gov (United States)

    Li, Songci; Andreev, Anton

    In Weyl materials the valence and conduction electron bands touch at an even number of isolated points in the Brillouin zone. In the vicinity of these points the electron dispersion is linear and may be described by the massless Dirac equation. This results in nontrivial topology of Berry connection curvature. One of its consequences is the existence of peculiar surface electron states whose Fermi surfaces form arcs connecting projections of the Weyl points onto the surface plane. Band bending near the boundary of the crystal also produces surface states. We show that in Weyl materials band bending near the crystal surface gives rise to spiral structure of energy surfaces of arc states. The corresponding Fermi surface has the shape of a spiral that winds about the projection of the Weyl point onto the surface plane. The direction of the winding is determined by the helicity of the Weyl point and the sign of the band bending potential. For close valleys arc state morphology may be understood in terms of avoided crossing of oppositely winding spirals. This work is supported by the U.S. Department of Energy Office of Science, Basic Energy Sciences under Award Number DE-FG02-07ER46452.

  4. GlidArc-assisted processing of biogas

    Energy Technology Data Exchange (ETDEWEB)

    Czernichowski, A.; Wesolowska, K. (ECP, La Ferte St Aubin (France)), Email: echph@wanadoo.fr

    2009-07-01

    Power generation or chemical applications of biogas can be difficult when CH{sub 4} content is too low and / or in the presence of sulphur compounds. We therefore propose two reformers based on electric discharges (GlidArc) that strike directly either in a poor biogas or in waste CO{sub 2} + H{sub 2}S mixture generated during biogas cleaning. Direct application of GlidArc discharges to the poor biogas enhances its flammability through a partial conversion of CH{sub 4} + CO{sub 2} into hydrogen and carbon monoxide (synthesis gas). Any level of sulphur (and other impurities) is accepted. Roughly 40 % of injected electric power is transferred into upgraded biogas as its additional chemical enthalpy. A few percent of resultant H{sub 2} and CO inside the biogas makes it more flammable, and therefore better to fuel an engine or gas turbine. As a result of biogas purification via amines-washing technologies, one gets concentrated pollutants in CO{sub 2} matrix. Instead of classical neutralisation, we propose H{sub 2}Svalorisation through the SulfArc process converting all H{sub 2}S into additional amounts of synthesis gas, while neutral elemental sulphur is removed from the system. Generated syngas can be injected into the main biogas flow to enhance its flammability. (orig.)

  5. Arc melter demonstration baseline test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process.

  6. Arc melter demonstration baseline test results

    International Nuclear Information System (INIS)

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process

  7. SU-C-BRB-05: Investigation of Conformal Arc Therapy Utilizing Newly Designed Cobalt 60 Machine

    Energy Technology Data Exchange (ETDEWEB)

    Eldib, A [Fox Chase Cancer Center, Philadelphia, PA (United States); Department of Physics, AlAzhar University, Cairo (Egypt); Chibani, O; Jin, L; Li, J; Veltchev, I; Price, R; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal)

    2015-06-15

    Purpose: A new modernized design for cobalt 60 (Co-60) machines is being developed with a ring type gantry. In this study we investigate the beneficial outcome of the new design for conformal arc therapy for various clinical sites. The new modality was evaluated based on isodose distributions and dose volume histograms as compared to 6MV photon beams from conventional linear accelerators. Methods: Computed tomographic images of seven different SBRT patients were selected from our patient database. All of these cases were previously planned on the Eclipse treatment planning system. New plans for these patients were generated with a modified conformal arc technique using both 6MV and Co-60 beams. The conformal arc was created by the delivery of treatment fields conformal to the target cross-section at every 5 or 10 degrees. The field shape was modified or turned off when it initially passed through a critical structure. Monte Carlo codes, MCBEAM and MCPLAN, were used for the machine head simulation and phantom/patient dose calculation, respectively. In the new Co-60 machine design, the source-to-isocenter distance was 60cm and the treatment head included the Co-60 source, primary collimator, jaws and MLC. Results: For all cases investigated, conformal arc plans utilizing Co-60 beams achieved similar conformity (mean conformity index=1.19) comparing to 6MV photon beams. Isodose distributions were tailored similarly around the PTV; both Co-60 and 6MV plans met our clinical acceptance criteria for the target coverage, and the maximum and minimum target doses. The DVH for the Co-60 plans showed slightly lower doses to the critical structures although the differences were small in most cases. Conclusion: There were no significant dosimetric differences between 6MV and Co-60 plans. Our results confirmed that this new Co-60 design could be a cost-effective machine for advanced radiotherapy due to its low cost, low maintenance and high up time.

  8. Stud arc welding in a magnetic field – Investigation of the influences on the arc motion

    International Nuclear Information System (INIS)

    Stud arc welding is widely used in the construction industry. For welding of studs with a diameter larger than 14 mm a ceramic ferrule is usually necessary in order to protect the weld pool. Disadvantages of using such a ferrule are that more metal is molten than necessary for a high quality welded joint and that the ferrule is a consumable generally thrown away after the welding operation. Investigations show that the ferrule can be omitted when the welding is carried out in a radially symmetric magnetic field within a shielding gas atmosphere. Due to the Lorentz force the arc is laterally shifted so that a very uniform and controlled melting of the stud contact surface as well as of the work piece can be achieved. In this paper a simplified physical model is presented describing how the parameters welding current, flux density of the magnetic field, radius of the arc and mass density of the shielding gas influence the velocity of the arc motion. The resulting equation is subsequently verified by comparing it to optical measurements of the arc motion. The proposed model can be used to optimize the required field distribution for the magnetic field stud welding process

  9. Stud arc welding in a magnetic field - Investigation of the influences on the arc motion

    Science.gov (United States)

    Hartz-Behrend, K.; Marqués, J. L.; Forster, G.; Jenicek, A.; Müller, M.; Cramer, H.; Jilg, A.; Soyer, H.; Schein, J.

    2014-11-01

    Stud arc welding is widely used in the construction industry. For welding of studs with a diameter larger than 14 mm a ceramic ferrule is usually necessary in order to protect the weld pool. Disadvantages of using such a ferrule are that more metal is molten than necessary for a high quality welded joint and that the ferrule is a consumable generally thrown away after the welding operation. Investigations show that the ferrule can be omitted when the welding is carried out in a radially symmetric magnetic field within a shielding gas atmosphere. Due to the Lorentz force the arc is laterally shifted so that a very uniform and controlled melting of the stud contact surface as well as of the work piece can be achieved. In this paper a simplified physical model is presented describing how the parameters welding current, flux density of the magnetic field, radius of the arc and mass density of the shielding gas influence the velocity of the arc motion. The resulting equation is subsequently verified by comparing it to optical measurements of the arc motion. The proposed model can be used to optimize the required field distribution for the magnetic field stud welding process.

  10. Feasibility study of volumetric modulated arc therapy for the treatment of retroperitoneal sarcomas

    International Nuclear Information System (INIS)

    Radiotherapy for retroperitoneal sarcomas remains controversial and a technical challenge considering the threshold of contiguous critical organs tolerance. We performed consecutive RapidArc dosimetric plans in preoperative or postoperative setting. A dosimetric study was carried out from six preoperative (group A) and four postoperative (group B) CT-scans, performed in 7 patients. Prescribed dose was 45 and 50 Gy for groups A and B, respectively. The planning target volume (PTV) was defined as the clinical target volume (CTV) plus 5 mm. The CTV encompassed the gross tumor volume (GTV) plus 10 mm or the tumoral bed. The dosimetric plans were optimized on a RapidArc Eclipse console using the progressive resolution algorithm, PRO version 8.8. Normalization method allowed the coverage of 99% of the PTV by 95% of the dose. Mean PTV were 2318.5 ± 2223.9 cc [range 348-6198 cc] and 698.3 ± 216.6 cc [range 463 -933 cc] for groups A and B, respectively. Plans were optimized for single arcs in group B and for single or two arcs in group A. The contralateral kidney volume receiving 5 Gy (V5Gy) was 21.5 ± 23.3% [range 0-55%] and 3.1 ± 2.6% [range 0-7.3%] for groups A and B, respectively. The mean dose received by 1% of the kidney (D1%) was 5.6 ± 2.4 Gy [range 3.6 -7.6 Gy] for group A and 5.4 ± 0.7 Gy [range 4.3-6 Gy] for group B. The volume of small bowel excluding the PTV (small bowel-PTV) that received 40 Gy and 30 Gy (V40Gy and V30Gy) in group A were 7.5 ± 4.4% [range 5.4-14.1%] and 18.5 ± 7.1% [range 10-30.4%], respectively. In group B, small bowel-PTV V40Gy and V30Gy were 4.7 ± 3.3% [range 3.3-8%] and 21.6 ± 7.5% [range 9.4-30%] respectively. In a second step, we treated two patients in the postoperative group. Treatment time delivery with one arc was 74 seconds. No severe acute toxicity was observed. RapidArc technology for retroperitoneal sarcomas showed acceptable dosimetric results in preoperative or postoperative clinical situation. From the first treated

  11. Large seismic faults in the Hellenic arc

    Directory of Open Access Journals (Sweden)

    B. S. Papazachos

    1996-06-01

    Full Text Available Using information concerning reliable fault plane solutions, spatial distribution of strong earthquakes (Ms³ 6.0 as well as sea bottom and coastal topography, properties of the seismic faults (orientation, dimension, type of faulting were determined in seven shallow (h < 40 km seismogenic regions along the convex part of thc Hellenic arc (Hellenic trench and in four seismogenic regions of intermediate depth earthquakes (h = 40-100 km along the concave part of this arc. Except for the northwesternmost part of the Hellenic trench, where the strike-slip Cephalonia transform fault dominates, all other faults along this trench are low angle thrust faults. III thc western part of the trench (Zante-west Crete faults strike NW-SE and dip NE, while in its eastern part (east Crete-Rhodos faults strike WNW-ESE and dip NNE. Such system of faulting can be attributed to an overthrust of the Aegean lithosphere on the eastern Mediterranean lithosphere. The longest of these faults (L = 300 km is that which produced the largest known shallow earthquake in the Mediterranean area (21 July 365, Ms = 8.3 which is located near the southwestern coast of Crete. The second longest such fault (L = l 70 km is that which produced a large earthquake (December 1303, Ms = 8.0 in the easternmost part of the trench (east of Rhodos island. Both earthquakes were associated with gigantic tsunamis which caused extensive damage in the coast of many Eastern Mediterranean countries. Seismic faults of the intermediate depth earthquakes in the shallow part of the Benioff zone (h = 40- 100 km are of strike-slip type, with a thrust component. The orientations of these faults vary along the concave part of the arc in accordance with a subduction of remnants of all old lithospheric slab from the convex side (Mediterranean to the concave side (Aegean of thc Hellenic arc. The longest of these faults (L = 220 km is that which produced the largest known intermediate depth earthquake in the

  12. A synthetic diamond diode in volumetric modulated arc therapy dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Zani, Margherita; Bucciolini, Marta; Casati, Marta; Talamonti, Cinzia [Dipartimento di Scienze biomediche, sperimentali e cliniche, Università degli Studi di Firenze - Azienza Ospedaliero Universitaria Careggi, Largo Brambilla 3, I-50134 Firenze (Italy); Marinelli, Marco; Prestopino, Giuseppe; Tonnetti, Alessia; Verona-Rinati, Gianluca [INFN-Dipartimento di Ingegneria Industriale, Università di Roma “Tor Vergata”, Via del Politecnico 1, I-00133 Roma (Italy)

    2013-09-15

    Purpose: The aim of this work is to investigate the behavior of a single crystal diamond diode (SCDD) for volumetric modulated arc therapy (VMAT) dose verifications. This delivery technique is one of the most severe test of a dosimeter performance due to the modulation of the dose rate achieved by simultaneously changing the velocity of the gantry and the position of the collimator leaves. The performed measurements with VMAT photon beams can therefore contribute to an overall global validation of the device to be used in dose distribution verifications.Methods: The SCDD response to 6 MVRX has been tested and compared with reference ionization chambers and treatment planning system (TPS) calculations in different experiments: (a) measurements of output factors for small field sizes (square fields of side ranging between 8 mm and 104 mm) by SCDD and A1SL ionization chamber; (b) angular dependence evaluation of the entire experimental set-up by SCDD, A1SL, and Farmer ionization chambers; and (c) acquisition of dose profiles for a VMAT treatment of a pulmonary disease in latero-lateral and gantry-target directions by SCDD and A1SL ionization chamber.Results: The output factors measured by SCDD favorably compare with the ones obtained by A1SL, whose response is affected by the lack of charged particle equilibrium and by averaging effect when small fields are involved. From the experiment on angular dependence, a good agreement is observed among the diamond diode, the ion chambers, and the TPS. In VMAT profiles, the absorbed doses measured by SCDD and A1SL compare well with the TPS calculated ones. An overall better agreement is observed in the case of the diamond dosimeter, which is also showing a better accuracy in terms of distance to agreement in the high gradient regions.Conclusions: Synthetic diamond diodes, whose performance were previously studied for conformal and IMRT radiotherapy techniques, were found to be suitable detectors also for dosimetric measurements

  13. SU-E-T-542: Comparison of Stereotactic Radiosurgery (SRS) of Brain Lesions Using Gamma Knife, VMAT, IMRT, and Conformal Arcs

    Energy Technology Data Exchange (ETDEWEB)

    Li, S; Charpentier, P; Chan, P; Neicu, T; Miyamoto, C [Temple University Hospital, Phila., PA (United States)

    2014-06-01

    Purpose: To compare dose distributions in stereotactic radiation surgery of brain lesions using gamma Knife, VMAT, conformal arcs, and IMRT in order to provide an optimal treatment. Methods: Dose distributions from single shot of 4C model of Gamma Knife at the helmet collimation sizes of 4, 8, 14, and 18 mm in diameter were compared with full arcs with the square shapes of 4×4 (or 5×5), 8×8 (or 10×10), and spherical shapes of 16 or 20 mm in diameter using EDR3 films in the same gamma knife QA phantom. Plans for ten SRS cases with single and multiple lesions were created in gamma knife plans and Pinnacle plans. The external beam plans had enlarged field size by 2-mm and used single conformal full circle arc for solitary lesion and none coplanar arcs/beams for multiple lesions. Coverage, conformity index, dose to critical organs, and integral dose to the brain and nearby critical structures were compared on all plans. Structures and dose matrices were registered in a Velocity deformable image registration system. Results: Single full circle arc from Elekta beam-modulate MLC (4-mm leaf thickness) and agility MLC (5-mm leaf thickness) have larger penumbra and less flatness than that of Gamma Knife single shot. None-coplanar arcs or beams were required to achieve similar dose distribution. In general, Gamma Knife plans provided significant less integral dose than that of linac-based plans. Benefits of IMRT and VMAT versus gamma Knife and conformal arcs were not significant. Conclusion: Our dose measurement and treatment planning evaluation clearly demonstrated dose distribution differences amount current popular SRS modalities for small solitary and multiple brain lesions. The trend of using MLC shape beams or arcs to replace conventional cones should be revisited in order to keep lower integral dose if the late correlates with some radiation-induced side effects. Pilot grant from Elekta LLC.

  14. Fast Arc-Annotated Subsequence Matching in Linear Space

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li

    2010-01-01

    An arc-annotated string is a string of characters, called bases, augmented with a set; of pairs, called arcs, each connecting two bases. Given arc-annotated strings P and Q the arc-preserving subsequence problem is to determine if P can be obtained from Q by deleting bases from Q. Whenever a base...... is deleted any arc with an endpoint in that base is also deleted. Arc-annotated strings where the arcs are "nested" are a natural model of RNA molecules that captures both the primary and secondary structure of these. The arc-preserving subsequence problem for nested arc-annotated strings is basic primitive...... the previous time bound while significantly reducing the space from a quadratic term to linear. This is essential to process large RNA molecules where the space is a likely to be a bottleneck. To obtain our result we introduce several novel ideas which may be of independent interest for related problems on arc-annotated...

  15. Characteristics of Atmospheric Pressure Rotating Gliding Arc Plasmas

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hao; ZHU Fengsen; TU Xin; BO Zheng; CEN Kefa; LI Xiaodong

    2016-01-01

    In this work,a novel direct current (DC) atmospheric pressure rotating gliding arc (RGA) plasma reactor has been developed for plasma-assisted chemical reactions.The influence of the gas composition and the gas flow rate on the arc dynamic behaviour and the formation of reactive species in the N2 and air gliding arc plasmas has been investigated by means of electrical signals,high speed photography,and optical emission spectroscopic diagnostics.Compared to conventional gliding arc reactors with knife-shaped electrodes which generally require a high flow rate (e.g.,10-20 L/min) to maintain a long arc length and reasonable plasma discharge zone,in this RGA system,a lower gas flow rate (e.g.,2 L/min) can also generate a larger effective plasma reaction zone with a longer arc length for chemical reactions.Two different motion patterns can be clearly observed in the N2 and air RGA plasmas.The time-resolved arc voltage signals show that three different arc dynamic modes,the arc restrike mode,takeover mode,and combined modes,can be clearly identified in the RGA plasmas.The occurrence of different motion and arc dynamic modes is strongly dependent on the composition of the working gas and gas flow rate.

  16. Characteristics of Atmospheric Pressure Rotating Gliding Arc Plasmas

    Science.gov (United States)

    Zhang, Hao; Zhu, Fengsen; Tu, Xin; Bo, Zheng; Cen, Kefa; Li, Xiaodong

    2016-05-01

    In this work, a novel direct current (DC) atmospheric pressure rotating gliding arc (RGA) plasma reactor has been developed for plasma-assisted chemical reactions. The influence of the gas composition and the gas flow rate on the arc dynamic behaviour and the formation of reactive species in the N2 and air gliding arc plasmas has been investigated by means of electrical signals, high speed photography, and optical emission spectroscopic diagnostics. Compared to conventional gliding arc reactors with knife-shaped electrodes which generally require a high flow rate (e.g., 10-20 L/min) to maintain a long arc length and reasonable plasma discharge zone, in this RGA system, a lower gas flow rate (e.g., 2 L/min) can also generate a larger effective plasma reaction zone with a longer arc length for chemical reactions. Two different motio