WorldWideScience

Sample records for arc delivery radiation

  1. Statistical quality control for volumetric modulated arc therapy (VMAT) delivery by using the machine's log data

    Science.gov (United States)

    Cheong, Kwang-Ho; Lee, Me-Yeon; Kang, Sei-Kwon; Yoon, Jai-Woong; Park, Soah; Hwang, Taejin; Kim, Haeyoung; Kim, Kyoung Ju; Han, Tae Jin; Bae, Hoonsik

    2015-07-01

    The aim of this study is to set up statistical quality control for monitoring the volumetric modulated arc therapy (VMAT) delivery error by using the machine's log data. Eclipse and a Clinac iX linac with the RapidArc system (Varian Medical Systems, Palo Alto, USA) are used for delivery of the VMAT plan. During the delivery of the RapidArc fields, the machine determines the delivered monitor units (MUs) and the gantry angle's position accuracy and the standard deviations of the MU ( σMU: dosimetric error) and the gantry angle ( σGA: geometric error) are displayed on the console monitor after completion of the RapidArc delivery. In the present study, first, the log data were analyzed to confirm its validity and usability; then, statistical process control (SPC) was applied to monitor the σMU and the σGA in a timely manner for all RapidArc fields: a total of 195 arc fields for 99 patients. The MU and the GA were determined twice for all fields, that is, first during the patient-specific plan QA and then again during the first treatment. The sMU and the σGA time series were quite stable irrespective of the treatment site; however, the sGA strongly depended on the gantry's rotation speed. The σGA of the RapidArc delivery for stereotactic body radiation therapy (SBRT) was smaller than that for the typical VMAT. Therefore, SPC was applied for SBRT cases and general cases respectively. Moreover, the accuracy of the potential meter of the gantry rotation is important because the σGA can change dramatically due to its condition. By applying SPC to the σMU and σGA, we could monitor the delivery error efficiently. However, the upper and the lower limits of SPC need to be determined carefully with full knowledge of the machine and log data.

  2. Effect of arc on radiation thermometry in welding process

    Institute of Scientific and Technical Information of China (English)

    李亮玉; 王燕; 武宝林

    2002-01-01

    The effect of arc on radiation thermometry is analyzed in a field close to the arc during the welding process, and the ratio of signal to noise and other factors are obtained for a small current arc .The method of the temperature measurement is feasible when the arc current is decreased to a smaller value in the welding process.

  3. Exposure assessment of aluminum arc welding radiation.

    Science.gov (United States)

    Peng, Chiung-yu; Lan, Cheng-hang; Juang, Yow-jer; Tsao, Ta-ho; Dai, Yu-tung; Liu, Hung-hsin; Chen, Chiou-jong

    2007-10-01

    The purpose of this study is to evaluate the non-ionizing radiation (NIR) exposure, especially optical radiation levels, and potential health hazard from aluminum arc welding processes based on the American Conference of Governmental Industrial Hygienists (ACGIH) method. The irradiance from the optical radiation emissions can be calculated with various biological effective parameters [i.e., S(lambda), B(lambda), R(lambda)] for NIR hazard assessments. The aluminum arc welding processing scatters bright light with NIR emission including ultraviolet radiation (UVR), visible, and infrared spectra. The UVR effective irradiance (Eeff) has a mean value of 1,100 microW cm at 100 cm distance from the arc spot. The maximum allowance time (tmax) is 2.79 s according to the ACGIH guideline. Blue-light hazard effective irradiance (EBlue) has a mean value of 1840 microW cm (300-700 nm) at 100 cm with a tmax of 5.45 s exposure allowance. Retinal thermal hazard effective calculation shows mean values of 320 mW cm(-2) sr(-1) and 25.4 mW (cm-2) (380-875 nm) for LRetina (spectral radiance) and ERetina (spectral irradiance), respectively. From this study, the NIR measurement from welding optical radiation emissions has been established to evaluate separate types of hazards to the eye and skin simultaneously. The NIR exposure assessment can be applied to other optical emissions from industrial sources. The data from welding assessment strongly suggest employees involved in aluminum welding processing must be fitted with appropriate personal protection devices such as masks and gloves to prevent serious injuries of the skin and eyes upon intense optical exposure.

  4. Dosimetric verification of RapidArc treatment delivery

    DEFF Research Database (Denmark)

    Korreman, Stine; Medin, Joakim; Kjaer-Kristoffersen, Flemming

    2009-01-01

    PURPOSE: Recently, Varian Medical Systems have announced the introduction of a new treatment technique, in which dose is delivered over a single gantry rotation with variable MLC positions, dose rate and gantry speed. In February 2008, a preclinical installation of the RapidArc beam delivery appr...

  5. Influence of metal vapour on arc temperatures in gas-metal arc welding: convection versus radiation

    Science.gov (United States)

    Murphy, Anthony B.

    2013-06-01

    The presence of metal vapour in gas-metal arc welding has been shown to have two strong effects on the arc plasma: a decrease in temperature throughout the arc, and the formation of a local temperature minimum near the arc axis. These effects have been attributed, on the basis of different computational models, to either the increased radiative emission associated with the presence of metal vapour in the arc plasma, or the influence of the metal vapour influx on convective flow in the arc. This question is investigated using a three-dimensional computational model in which the production and the transport of metal vapour are taken into account self-consistently. Parameters relevant to welding of thin sheets of aluminum are examined. For these conditions, it is found that the first effect (the decrease in temperature throughout the arc) is due to both the increased radiative emission and the influence of the metal vapour influx on flow. The second effect (the local temperature minimum, which in this case occurs just below the wire electrode) is a consequence of the influence of aluminum vapour produced from the wire electrode on flow in the arc. By examining published results and the energy balance in the plasma, it is shown that for welding of steel with higher arc currents, the increased radiative emission can lead to a local temperature minimum at a greater distance from the wire electrode.

  6. Ultraviolet radiation emitted by CO(2) arc welding.

    Science.gov (United States)

    Okuno, T; Ojima, J; Saito, H

    2001-10-01

    The arcs associated with arc welding emit high levels of ultraviolet radiation (UVR), and this often causes acute injuries in the workplace, particularly photokeratoconjunctivitis. It is important to know the level of UVR emitted by arc welding under various conditions, as this information will help in evaluating potential UVR hazards in welding workplaces and taking protective measures against it. In this study, the ACGIH effective irradiance for UVR was measured experimentally for CO(2) arc welding in order to evaluate its UVR hazards. A welding robot was used in the experiment in order to realize reproducible and consistent welding operations. The effective irradiance at 1 m from the arc was in the range 0.28-7.85 W/m(2) (28-785 microW/cm(2)) under the study conditions. The corresponding permissible exposure time per day is only 4-100 s, suggesting that UVR from CO(2) arc welding is actually hazardous for the eye and skin. It was found that the effective irradiance is inversely proportional to the square of the distance from the arc, is strongly dependent on the direction of emission from the arc with a maximum at 50-60 degrees from the plate surface, and tends to increase with welding current.

  7. Electromagnetic radiation generated by arcing in low density plasma

    Science.gov (United States)

    Vayner, Boris V.; Ferguson, Dale C.; Snyder, David B.; Doreswamy, C. V.

    1996-01-01

    An unavoidable step in the process of space exploration is to use high-power, very large spacecraft launched into Earth orbit. Obviously, the spacecraft will need powerful energy sources. Previous experience has shown that electrical discharges occur on the surfaces of a high-voltage array, and these discharges (arcs) are undesirable in many respects. Moreover, any high voltage conductor will interact with the surrounding plasma, and that interaction may result in electrical discharges between the conductor and plasma (or between two conductors with different potentials, for example, during docking and extravehicular activity). One very important aspect is the generation of electromagnetic radiation by arcing. To prevent the negative influence of electromagnetic noise on the operation of spacecraft systems, it seems necessary to determine the spectra and absolute levels of the radiation, and to determine limitations on the solar array bias voltage that depend on the parameters of LEO plasma and the technical requirements of the spacecraft equipment. This report describes the results of an experimental study and computer simulation of the electromagnetic radiation generated by arcing on spacecraft surfaces. A large set of high quality data was obtained during the Solar Array Module Plasma Interaction Experiment (SAMPIE, flight STS-62) and ground test. These data include the amplitudes of current, pulse forms, duration of each arc, and spectra of plasma waves. A theoretical explanation of the observed features is presented in this report too. The elaborated model allows us to determine the parameters of the electromagnetic noise for different frequency ranges, distances from the arcing site, and distinct kinds of plasma waves.

  8. Sensitivity of collapsed arc QA method for delivery errors in Volumetric Modulated Arc Therapy (VMAT)

    Science.gov (United States)

    Young, Tony; Xing, Aitang; Vial, Philp; Thwaites, David; Holloway, Lois; Arumugam, Sankar

    2015-01-01

    In this paper the sensitivity of an Electronic Portal Imaging Device (EPID) to detecting introduced Volumetric Arc Therapy (VMAT) treatment errors was studied using the Collapsed Arc method. Two clinical Head and Neck (H&N) and Prostate treatment plans had gantry dependent dose and MLC errors introduced to the plans. These plans were then delivered to an Elekta Synergy Linear Accelerator EPID and compared to the original treatment planning system Collapsed Arc dose matrix. With the Collapsed Arc technique the EPID was able to detect MLC errors down to 2mm and dose errors of down to 3% depending on the treatment plan complexity and gamma tolerance used.

  9. Statistical quality control for volumetric modulated arc therapy (VMAT) delivery using machine log data

    CERN Document Server

    Cheong, Kwang-Ho; Kang, Sei-Kwon; Yoon, Jai-Woong; Park, Soah; Hwang, Taejin; Kim, Haeyoung; Kim, Kyoung Ju; Han, Tae Jin; Bae, Hoonsik

    2015-01-01

    The aim of this study is to set up statistical quality control for monitoring of volumetric modulated arc therapy (VMAT) delivery error using machine log data. Eclipse and Clinac iX linac with the RapidArc system (Varian Medical Systems, Palo Alto, USA) is used for delivery of the VMAT plan. During the delivery of the RapidArc fields, the machine determines the delivered motor units (MUs) and gantry angle position accuracy and the standard deviations of MU (sigma_MU; dosimetric error) and gantry angle (sigma_GA; geometric error) are displayed on the console monitor after completion of the RapidArc delivery. In the present study, first, the log data was analyzed to confirm its validity and usability; then, statistical process control (SPC) was applied to monitor the sigma_MU and sigma_GA in a timely manner for all RapidArc fields: a total of 195 arc fields for 99 patients. The sigma_MU and sigma_GA were determined twice for all fields, that is, first during the patient-specific plan QA and then again during th...

  10. Radiation sterilization of new drug delivery systems.

    Science.gov (United States)

    Abuhanoğlu, Gürhan; Ozer, A Yekta

    2014-06-01

    Radiation sterilization has now become a commonly used method for sterilization of several active ingredients in drugs or drug delivery systems containing these substances. In this context, many applications have been performed on the human products that are required to be sterile, as well as on pharmaceutical products prepared to be developed. The new drug delivery systems designed to deliver the medication to the target tissue or organ, such as microspheres, nanospheres, microemulsion, and liposomal systems, have been sterilized by gamma (γ) and beta (β) rays, and more recently, by e-beam sterilization. In this review, the sterilization of new drug delivery systems was discussed other than conventional drug delivery systems by γ irradiation.

  11. Direct leaf trajectory optimization for volumetric modulated arc therapy planning with sliding window delivery

    CERN Document Server

    Papp, Dávid

    2013-01-01

    We propose a novel optimization model for volumetric modulated arc therapy (VMAT) planning that directly optimizes deliverable leaf trajectories in the treatment plan optimization problem, and eliminates the need for a separate arc-sequencing step. In this model, a 360-degree arc is divided into a given number of arc segments in which the leaves move unidirectionally. This facilitates an algorithm that determines the optimal piecewise linear leaf trajectories for each arc segment, which are deliverable in a given treatment time. Multi-leaf collimator (MLC) constraints, including maximum leaf speed and interdigitation, are accounted for explicitly. The algorithm is customized to allow for VMAT delivery using constant gantry speed and dose rate, however, the algorithm generalizes to variable gantry speed if beneficial. We demonstrate the method for three different tumor sites: a head-and-neck case, a prostate case, and a paraspinal case. For that purpose, we first obtain a reference plan for intensity modulated...

  12. Arc binary intensity modulated radiation therapy (AB IMRT)

    Science.gov (United States)

    Yang, Jun

    The state of the art Intensity Modulate Radiation Therapy (IMRT) has been one of the most significant breakthroughs in the cancer treatment in the past 30 years. There are two types of IMRT systems. The first system is the binary-based tomotherapy, represented by the Peacock (Nomos Corp) and Tomo unit (TomoTherapy Inc.), adopting specific binary collimator leafs to deliver intensity modulated radiation fields in a serial or helical fashion. The other uses the conventional dynamic multileaf collimator (MLC) to deliver intensity modulated fields through a number of gantry positions. The proposed Arc Binary IMRT attempts to deliver Tomo-like IMRT with conventional dynamic MLC and combines the advantages of the two types of IMRT techniques: (1) maximizing the number of pencil beams for better dose optimization, (2) enabling conventional linear accelerator with dynamic MLC to deliver Tomo-like IMRT. In order to deliver IMRT with conventional dynamic MLC in a binary fashion, the slice-by-slice treatment with limited slice thickness has been proposed in the thesis to accommodate the limited MLC traveling speed. Instead of moving the patient to subsequent treatment slices, the proposed method offsets MLC to carry out the whole treatment, slice by slice sequentially, thus avoid patient position error. By denoting one arc pencil beam set as a gene, genetic algorithm (GA) is used as the searching engine for the dose optimization process. The selection of GA parameters is a crucial step and has been studied in depth so that the optimization process will converge with reasonable speed. Several hypothetical and clinical cases have been tested with the proposed IMRT method. The comparison of the dose distribution with other commercially available IMRT systems demonstrates the clear advantage of the new method. The proposed Arc Binary Intensity Modulated Radiation Therapy is not only theoretically sound but practically feasible. The implementation of this method would expand the

  13. Multigroup Approximation of Radiation Transfer in SF6 Arc Plasmas

    Directory of Open Access Journals (Sweden)

    Milada Bartlova

    2013-01-01

    Full Text Available The first order of the method of spherical harmonics (P1-approximation has been used to evaluate the radiation properties of arc plasmas of various mixtures of SF6 and PTFE ((C2F4n, polytetrafluoroethylene in the temperature range (1000 ÷ 35 000 K and pressures from 0.5 to 5 MPa. Calculations have been performed for isothermal cylindrical plasma of various radii (0.01 ÷ 10 cm. The frequency dependence of the absorption coefficients has been handled using the Planck and Rosseland averaging methods for several frequency intervals. Results obtained using various means calculated for different choices of frequency intervals are discussed.

  14. SU-E-T-187: Feasibility Study of Stereotactic Liver Radiation Therapy Using Multiple Divided Partial Arcs in Volumetric Modulated Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Y; Ozawa, S; Tsegmed, U; Nakashima, T; Shintaro, T; Ochi, Y; Kawahara, D; Kimura, T; Nagata, Y [Hiroshima University, Hiroshima, Hiroshima (Japan)

    2014-06-01

    Purpose: To verify volumetric modulated arc therapy (VMAT) using flattening filter free (FFF) mode with jaw tracking (JT) feature for single breath hold as long as 15 s per arc in liver stereotactic body radiation therapy (SBRT) against intensity modulated radiation therapy (IMRT) FFF-JT. Methods: Ten hepatocellular carcinoma (HCC) cases were planned with 10 MV FFF using Pinnacle3 treatment planning system which delivered by TrueBeam to administer 48 Gy/ 4 fractions. Eight non-coplanar beams were assigned to IMRT using step-and-shoot technique. For VMAT, two or three non-coplanar partial arcs (up to 180 degrees) were further divided into subarcs with gantry rotation less than 80 degrees to limit delivery time within 15 s. Dose distributions were verified using OCTAVIUS II system and pass rates were evaluated using gamma analysis with criteria of 3%/3 mm at threshold of 5% to the maximum dose. The actual irradiation time was measured. Results: The VMAT-FFF-JT of partial-arcs with sub-divided arcs was able to produce a highly conformal plan as well as IMRT-FFF-JT. Isodose lines and DVH showed slight improvement in dosimetry when JT was employed for both IMRT and VMAT. Consequently, VMAT-FFF-JT was superior in reducing the dose to liver minus gross tumor volume. VMAT-FFF-JT has shorter total treatment time compared with 3D conformal radiation therapy (3D-CRT) FFF because the gantry was rotated simultaneously with the beam delivery in VMAT. Moreover, due to the small and regular shape of HCC, VMAT-FFF-JT offered less multileaf collimator motion, thus the interplay effect is expected to be reduced. The patient specific QA of IMRT and VMAT acquired the pass rates higher than 90%. Conclusion: VMAT-FFF-JT could be a promising technique for liver SBRT as the sub-divided arcs method was able to accommodate a single breath hold irradiation time of less than 15 s without deterioration of the dose distribution compared with IMRT-FFF-JT.

  15. Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer : a planning study

    NARCIS (Netherlands)

    Holt, Andrea; Van Gestel, Dirk; Arends, Mark P.; Korevaar, Erik W.; Schuring, Danny; Kunze-Busch, Martina C.; Louwe, Rob J. W.; van Vliet-Vroegindeweij, Corine

    2013-01-01

    Background: Compared to static beam Intensity-Modulated Radiation Therapy (IMRT), the main advantage of Volumetric Modulated Arc Therapy (VMAT) is a shortened delivery time, which leads to improved patient comfort and possibly smaller intra-fraction movements. This study aims at a treatment planner-

  16. Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study

    NARCIS (Netherlands)

    Holt, A.; Gestel, D. Van; Arends, M.P.; Korevaar, E.W.; Schuring, D.; Kunze-Busch, M.C.; Louwe, R.J.W.; Vliet-Vroegindeweij, C. van

    2013-01-01

    BACKGROUND: Compared to static beam Intensity-Modulated Radiation Therapy (IMRT), the main advantage of Volumetric Modulated Arc Therapy (VMAT) is a shortened delivery time, which leads to improved patient comfort and possibly smaller intra-fraction movements. This study aims at a treatment planner-

  17. Artificial Optical Radiation photobiological hazards in arc welding.

    Science.gov (United States)

    Gourzoulidis, G A; Achtipis, A; Topalis, F V; Kazasidis, M E; Pantelis, D; Markoulis, A; Kappas, C; Bourousis, C A

    2016-08-01

    Occupational Health and Safety (OHS) is associated with crucial social, economic, cultural and technical issues. A highly specialized OHS sector deals with the photobiological hazards from artificial optical radiation (AOR), which is divided into visible light, UV and IR emitted during various activities and which is legally covered by European Directive 2006/25/EC. Among the enormous amount of sources emitting AOR, the most important non-coherent ones to consider for health effects to the whole optical range, are arcs created during metal welding. This survey presents the effort to assess the complicated exposure limits of the Directive in the controlled environment of a welding laboratory. Sensors covering the UV and blue light range were set to measure typical welding procedures reproduced in the laboratory. Initial results, apart from apparently justifying the use of Personal Protective Equipment (PPE) due to even subsecond overexposures measured, also set the basis to evaluate PPE's properties and support an integrated risk assessment of the complex welding environment. These results can also improve workers' and employer's information and training about radiation hazards, which is a crucial OHS demand.

  18. A Theoretical Model of Arc Light Radiation Based on GTA Spectral Diagnosis

    Institute of Scientific and Technical Information of China (English)

    Chenming XU; Hongming GAO; Guangjun ZHANG; Lin WU

    2003-01-01

    An arc light radiation phenomenon in TIG welding process was studied through experiments and theoretical analysis.The arc spectra were acquired under a variety of welding parameters from 200 nm to 1000 nm wavelength rangein TIG. The influence of welding p

  19. Excited atoms in the free-burning Ar arc: treatment of the resonance radiation

    Science.gov (United States)

    Golubovskii, Yu; Kalanov, D.; Gortschakow, S.; Baeva, M.; Uhrlandt, D.

    2016-11-01

    The collisional-radiative model with an emphasis on the accurate treatment of the resonance radiation transport is developed and applied to the free-burning Ar arc plasma. This model allows for analysis of the influence of resonance radiation on the spatial density profiles of the atoms in different excited states. The comparison of the radial density profiles obtained using an effective transition probability approximation with the results of the accurate solution demonstrates the distinct impact of transport on the profiles and absolute densities of the excited atoms, especially in the arc fringes. The departures from the Saha-Boltzmann equilibrium distributions, caused by different radiative transitions, are analyzed. For the case of the DC arc, the local thermodynamic equilibrium (LTE) state holds close to the arc axis, while strong deviations from the equilibrium state on the periphery occur. In the intermediate radial positions the conditions of partial LTE are fulfilled.

  20. Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ashamalla, Hani; Tejwani, Ajay; Parameritis, Loannis; Swamy, Uma; Luo, Pei Ching; Guirguis, Adel; Lavaf, Amir [Weill Medical College of Cornell University, Brooklyn, NY (United States)

    2013-06-15

    Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Sixteen patients were studied. Prostate (PTV{sub P}), right pelvic (PTV{sub RtLN}) and left pelvic lymph nodes (PTV{sub LtLN}), and organs at risk were contoured. PTVP, PTV{sub RtLN}, and PTV{sub LtLN} received 50.40 Gy followed by a boost to PTV{sub B} of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose (D{sub MEAN}) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The D{sub MEAN} of bladder was within 2% of each other. The rectum D{sub MEAN} in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.

  1. Development of a novel ArcCHECK{sup Trade-Mark-Sign} insert for routine quality assurance of VMAT delivery including dose calculation with inhomogeneities

    Energy Technology Data Exchange (ETDEWEB)

    Fakir, H.; Gaede, S.; Mulligan, M.; Chen, J. Z. [Department of Physics, London Regional Cancer Program, London, Ontario N6A 4L6 (Canada)

    2012-07-15

    Purpose: To design a versatile, nonhomogeneous insert for the dose verification phantom ArcCHECK{sup Trade-Mark-Sign} (Sun Nuclear Corp., FL) and to demonstrate its usefulness for the verification of dose distributions in inhomogeneous media. As an example, we demonstrate it can be used clinically for routine quality assurance of two volumetric modulated arc therapy (VMAT) systems for lung stereotactic body radiation therapy (SBRT): SmartArc{sup Registered-Sign} (Pinnacle{sup 3}, Philips Radiation Oncology Systems, Fitchburg, WI) and RapidArc{sup Registered-Sign} (Eclipse{sup Trade-Mark-Sign }, Varian Medical Systems, Palo Alto, CA). Methods: The cylindrical detector array ArcCHECK{sup Trade-Mark-Sign} has a retractable homogeneous acrylic insert. In this work, we designed and manufactured a customized heterogeneous insert with densities that simulate soft tissue, lung, bone, and air. The insert offers several possible heterogeneity configurations and multiple locations for point dose measurements. SmartArc{sup Registered-Sign} and RapidArc{sup Registered-Sign} plans for lung SBRT were generated and copied to ArcCHECK{sup Trade-Mark-Sign} for each inhomogeneity configuration. Dose delivery was done on a Varian 2100 ix linac. The evaluation of dose distributions was based on gamma analysis of the diode measurements and point doses measurements at different positions near the inhomogeneities. Results: The insert was successfully manufactured and tested with different measurements of VMAT plans. Dose distributions measured with the homogeneous insert showed gamma passing rates similar to our clinical results ({approx}99%) for both treatment-planning systems. Using nonhomogeneous inserts decreased the passing rates by up to 3.6% in the examples studied. Overall, SmartArc{sup Registered-Sign} plans showed better gamma passing rates for nonhomogeneous measurements. The discrepancy between calculated and measured point doses was increased up to 6.5% for the nonhomogeneous

  2. Dosimetric and radiobiological comparison of Forward Tangent Intensity Modulated Radiation Therapy (FT-IMRT) and Volumetric Modulated Arc Therapy (VMAT) for early stage whole breast cancer

    Science.gov (United States)

    Moshiri Sedeh, Nader

    Intensity Modulated Radiation Therapy (IMRT) is a well-known type of external beam radiation therapy. The advancement in technology has had an inevitable influence in radiation oncology as well that has led to a newer and faster dose delivery technique called Volumetric Modulated Arc Therapy (VMAT). Since the presence of the VMAT modality in clinics in the late 2000, there have been many studies in order to compare the results of the VMAT modality with the current popular modality IMRT for various tumor sites in the body such as brain, prostate, head and neck, cervix and anal carcinoma. This is the first study to compare VMAT with IMRT for breast cancer. The results show that the RapidArc technique in Eclipse version 11 does not improve all aspects of the treatment plans for the breast cases automatically and easily, but it needs to be manipulated by extra techniques to create acceptable plans thus further research is needed.

  3. A Two-Flux Radiation Model for Helical Instability of Arcs

    Institute of Scientific and Technical Information of China (English)

    GONG Ye; ZHENG Shu; XU Xiang; ZOU Xiu; LIU Jin-Yuan; LIU Yue; WANG Xiao-Gang

    2005-01-01

    @@ A two-flux radiation model of the helical instability of arcs in axial magnetic field is presented. The temperature (and electrical conductivity) is approximated in a more realistic way (parabolic instead of flat profile) and a simplified term of radiation losses is included in the energy equation. The magnetohydrodynamic equations in an electrostatic approximation serve as the starting point of the theory. Using a linear time-dependent perturbation theory, the corresponding equations and an explicit analytic expression that corresponds to the term of radiation losses are derived in the presence of the radiation transfer energy, from which the marginal Maecker number and the growth rate of the helical instability can be given. It is found that, in comparison with the results without radiation, the arc stable area is reduced.

  4. Robotic Delivery of Complex Radiation Volumes for Small Animal Research.

    Science.gov (United States)

    Matinfar, Mohammad; Iordachita, Iulian; Wong, John; Kazanzides, Peter

    2010-07-15

    The Small Animal Radiation Research Platform (SARRP) is a novel and complete system capable of delivering multidirectional (focal), kilo-voltage radiation fields to targets in small animals under robotic control using cone-beam CT (CBCT) image guidance. The capability of the SARRP to deliver highly focused beams to multiple animal models provides new research opportunities that more realistically bridge laboratory research and clinical translation. This paper describes the design and operation of the SARRP for precise radiation delivery. Different delivery procedures are presented which enable the system to radiate through a series of points, representative of a complex shape. A particularly interesting case is shell dose irradiation, where the goal is to deliver a high dose of radiation to the shape surface, with minimal dose to the shape interior. The ability to deliver a dose shell allows mechanistic research of how a tumor interacts with its microenvironment to sustain its growth and lead to its resistance or recurrence.

  5. The influence of microwave radiation on transdermal delivery systems.

    Science.gov (United States)

    Moseley, H; Johnston, S; Allen, A

    1990-03-01

    It has been alleged that the exposure of a transdermal delivery system to leakage of microwave radiation from a domestic microwave oven can result in the user receiving a second-degree burn in the area of the patch. Several transdermal delivery systems were exposed to microwave radiation from an Electro Medical Supplies Microtron 200 microwave diathermy unit. Temperature rises of up to 2.2 degrees C were recorded at a maximum power density of 800 W/m2. These temperature rises were considered insignificant compared to that required to produce a burn. The exposure of transdermal delivery systems to a microwave diathermy field or lower level leakage radiation from a microwave oven is unlikely to cause direct thermal injury to the wearer.

  6. Collisional-Radiative Modeling of Free-Burning Arc Plasma in Argon

    Science.gov (United States)

    2013-06-01

    COLLISIONAL-RADIATIVE MODELING OF FREE-BURNING ARC PLASMA IN ARGON M. Baeva  , D. Uhrlandt, S. Gorchakov Leibniz Institute for Plasma...S) AND ADDRESS(ES) Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Strasse 2, 17489 Greifswald, Germany 8. PERFORMING

  7. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

    Energy Technology Data Exchange (ETDEWEB)

    Mail, Noor; Al-Ghamdi, S.; Saoudi, A. [Princess Norah Oncology Center, National Guard Health Affairs, Jeddah 21423, Saudi Arabia and King Abdullah International Medical Research Center, Jeddah 21423 (Saudi Arabia); Albarakati, Y.; Ahmad Khan, M.; Saeedi, F.; Safadi, N. [Princess Norah Oncology Center, National Guard Health Affairs, Jeddah 21423 (Saudi Arabia)

    2013-08-15

    Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined

  8. Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Scorsetti, Marta; Bignardi, Mario; Alongi, Filippo; Mancosu, Pietro; Navarria, Piera; Castiglioni, Simona; Pentimalli, Sara; Tozzi, Angelo (IRCCS Istituto Clinico Humanitas, Rozzano (Italy)), e-mail: pietro.mancosu@humanitas.it; Fogliata, Antonella; Cozzi, Luca (Oncology Inst. of Southern Switzerland, Bellinzona (Switzerland))

    2011-05-15

    Purpose. To report early clinical experience in stereotactic body radiation therapy (SBRT) delivered using volumetric intensity modulated arc therapy with RapidArc (RA) in patients with primary or metastatic tumours at abdominal sites. Material and methods. Thirty-seven consecutive patients were treated using RA. Of these, 16 had primary or metastatic liver tumours, nine had pancreatic cancer and 12 a nodal metastasis in the retro-peritoneum. Dose prescription varied from 45 to 75 Gy to the Clinical Target Volume in 3 to 6 fractions. The median follow-up was 12 months (6-22). Early local control and toxicity were investigated and reported. Results. Planning objectives on target volumes and organs at risk were met in most cases. Delivery time ranged from 2.8 +- 0.3 to 9.2 +- 2.4 minutes and pre-treatment plan verification resulted in a Gamma Agreement Index from 95.3 +- 3.8 to 98.3 +- 1.7%. At the time of analysis, local control (freedom from progression) at six months, was assessable in 24 of 37 patients and was achieved in 19 patients with a crude rate of 79.2%. Seven patients experienced treatment-related toxicity. Three patients experienced a mild and transient G1 enteritis and two showed a transient G1 liver damage. Two had late toxicity: one developed chronic enteritis causing G1 diarrhoea and G1 abdominal pain and one suffered at three months a G3 gastric bleeding. No patients experienced G4 acute toxicity. Conclusions. SBRT for abdominal targets delivered by means of RA resulted to be feasible with good early clinical results in terms of local control rate and acute toxicity profile. RA allowed to achieve required target coverage as well as to keep within normal tissue dose/volume constraints

  9. Comparative dosimetry of volumetric modulated arc therapy and limited-angle static intensity-modulated radiation therapy for early-stage larynx cancer

    Energy Technology Data Exchange (ETDEWEB)

    Riegel, Adam C.; Antone, Jeffrey [Department of Radiation Medicine, North Shore–LIJ Health System, New Hyde, Park, NY (United States); Schwartz, David L., E-mail: dschwartz3@nshs.edu [Department of Radiation Medicine, North Shore–LIJ Health System, New Hyde, Park, NY (United States); Hofstra–NSLIJ School of Medicine, Hempstead, NY (United States)

    2013-04-01

    To compare relative carotid and normal tissue sparing using volumetric-modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) for early-stage larynx cancer. Seven treatment plans were retrospectively created on 2 commercial treatment planning systems for 11 consecutive patients with T1-2N0 larynx cancer. Conventional plans consisted of opposed-wedged fields. IMRT planning used an anterior 3-field beam arrangement. Two VMAT plans were created, a full 360° arc and an anterior 180° arc. Given planning target volume (PTV) coverage of 95% total volume at 95% of 6300 cGy and maximum spinal cord dose below 2500 cGy, mean carotid artery dose was pushed as low as possible for each plan. Deliverability was assessed by comparing measured and planned planar dose with the gamma (γ) index. Full-arc planning provided the most effective carotid sparing but yielded the highest mean normal tissue dose (where normal tissue was defined as all soft tissue minus PTV). Static IMRT produced next-best carotid sparing with lower normal tissue dose. The anterior half-arc produced the highest carotid artery dose, in some cases comparable with conventional opposed fields. On the whole, carotid sparing was inversely related to normal tissue dose sparing. Mean γ indexes were much less than 1, consistent with accurate delivery of planned treatment. Full-arc VMAT yields greater carotid sparing than half-arc VMAT. Limited-angle IMRT remains a reasonable alternative to full-arc VMAT, given its ability to mediate the competing demands of carotid and normal tissue dose constraints. The respective clinical significance of carotid and normal tissue sparing will require prospective evaluation.

  10. Temperature rise induced in Si by continuous xenon arc lamp radiation

    Science.gov (United States)

    Lietoila, A.; Gold, R. B.; Gibbons, J. F.

    1982-02-01

    It is shown that practical beam annealing of silicon can be accomplished with a high intensity arc lamp. The use of a one-dimensional, steady-state solution for temperature is justified. The Kirchhoff transform is utilized to include the temperature dependence of the thermal conductivity. Surface temperatures produced by a xenon arc lamp are calculated for 300- and 375-μm thick silicon samples, using substrate temperatures of 350 and 500 °C. It is shown that substantial reduction of the radiation intensity required for a given surface temperature can be obtained by placing a quartz wafer between the silicon sample and the heat sink.

  11. Order Reduction of the Radiative Heat Transfer Model for the Simulation of Plasma Arcs

    CERN Document Server

    Fagiano, Lorenzo

    2015-01-01

    An approach to derive low-complexity models describing thermal radiation for the sake of simulating the behavior of electric arcs in switchgear systems is presented. The idea is to approximate the (high dimensional) full-order equations, modeling the propagation of the radiated intensity in space, with a model of much lower dimension, whose parameters are identified by means of nonlinear system identification techniques. The low-order model preserves the main structural aspects of the full-order one, and its parameters can be straightforwardly used in arc simulation tools based on computational fluid dynamics. In particular, the model parameters can be used together with the common approaches to resolve radiation in magnetohydrodynamic simulations, including the discrete-ordinate method, the P-N methods and photohydrodynamics. The proposed order reduction approach is able to systematically compute the partitioning of the electromagnetic spectrum in frequency bands, and the related absorption coefficients, tha...

  12. Feasibility study of a periodic arc compressor in the presence of coherent synchrotron radiation

    Science.gov (United States)

    Di Mitri, S.

    2016-01-01

    The advent of short electron bunches in high brightness linear accelerators has raised the awareness of the accelerator community to the degradation of the beam transverse emittance by coherent synchrotron radiation (CSR) emitted in magnetic bunch length compressors, transfer lines and turnaround arcs. Beam optics control has been proposed to mitigate that CSR effect. In this article, we enlarge on the existing literature by reviewing the validity of the linear optics approach in a periodic, achromatic arc compressor. We then study the dependence of the CSR-perturbed emittance to beam optics, mean energy, and bunch charge. The analytical findings are compared with particle tracking results. Practical considerations on CSR-induced energy loss and nonlinear particle dynamics are included. As a result, we identify the range of parameters that allows feasibility of an arc compressor for driving, for example, a free electron laser or a linear collider.

  13. Thermal radiation effect on the extinction properties of electric arcs in HV circuit breakers

    Directory of Open Access Journals (Sweden)

    Ziani Abderrahmane

    2009-01-01

    Full Text Available During the formation of the electric arc at the opening of a high voltage circuit breaker, the generated plasma will be the seat of a very important thermal exchange. Models founded only on conduction and convection thermal transfers don't reproduce the whole thermal exchanges that are governing the extinction process. This paper is devoted to the development of a model of the electric arc extinction in a high voltage circuit breaker taking in account the thermal radiation of the plasma, in addition to the conduction and convection phenomena. The Stefan-Boltzman equation is coupled with the heat equation, and both equations are solved simultaneously in order to follow the evolution of the arc voltage and the conductance of the thermal plasma. The obtained results are found in good agreement with experimental recordings.

  14. Feasibility study of a periodic arc compressor in the presence of coherent synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Di Mitri, S.

    2016-01-11

    The advent of short electron bunches in high brightness linear accelerators has raised the awareness of the accelerator community to the degradation of the beam transverse emittance by coherent synchrotron radiation (CSR) emitted in magnetic bunch length compressors, transfer lines and turnaround arcs. Beam optics control has been proposed to mitigate that CSR effect. In this article, we enlarge on the existing literature by reviewing the validity of the linear optics approach in a periodic, achromatic arc compressor. We then study the dependence of the CSR-perturbed emittance to beam optics, mean energy, and bunch charge. The analytical findings are compared with particle tracking results. Practical considerations on CSR-induced energy loss and nonlinear particle dynamics are included. As a result, we identify the range of parameters that allows feasibility of an arc compressor for driving, for example, a free electron laser or a linear collider.

  15. Influence of Welding Current and Focal Position on the Resonant Absorption of Laser Radiation in a TIG Welding Arc

    Science.gov (United States)

    Emde, B.; Huse, M.; Hermsdorf, J.; Kaierle, S.; Wesling, V.; Overmeyer, L.

    The work presents the influence of welding current and focal position on the resonant absorption of diode laser radiation in a TIG welding arc. The laser beam is guided perpendicular to the electrical arc to avoid an interaction with the electrodes. Laser power measurements have shown a reduction of the measured laser power up to 18% after passing the electrical arc. This reduction results from the interaction of argon shielding gas atoms and laser radiation at 810.4 nm and 811.5 nm. The interaction is strongly affected by the adjusted welding current and the adjustment of the laser beam and the electrical arc. Lowering the welding current or shifting the laser beam out of the centerline of the electrical arc reduces the ionization probability. An increased ionization is necessary to decrease the resistance of the electrical arc.

  16. An efficient Volumetric Arc Therapy treatment planning approach for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Jin [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY (United States); Bender, Edward [Department of Medical Physics, University of Wisconsin, Madison, WI (United States); Yaparpalvi, Ravindra; Kuo, Hsiang-Chi; Basavatia, Amar; Hong, Linda; Bodner, William; Garg, Madhur K.; Kalnicki, Shalom [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY (United States); Tomé, Wolfgang A., E-mail: wtome@montefiore.org [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY (United States); Department of Medical Physics, University of Wisconsin, Madison, WI (United States)

    2015-10-01

    An efficient and simple class solution is proposed for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT) planning using the Volumetric Arc Therapy (VMAT) delivery technique following the NRG Oncology protocol NRG-CC001 treatment planning guidelines. The whole-brain planning target volume (PTV) was subdivided into subplanning volumes that lie in plane and out of plane with the hippocampal-avoidance volume. To further improve VMAT treatment plans, a partial-field dual-arc technique was developed. Both the arcs were allowed to overlap on the in-plane subtarget volume, and in addition, one arc covered the superior out-of-plane sub-PTV, while the other covered the inferior out-of-plane subtarget volume. For all plans (n = 20), the NRG-CC001 protocol dose-volume criteria were met. Mean values of volumes for the hippocampus and the hippocampal-avoidance volume were 4.1 cm{sup 3} ± 1.0 cm{sup 3} and 28.52 cm{sup 3} ± 3.22 cm{sup 3}, respectively. For the PTV, the average values of D{sub 2%} and D{sub 98%} were 36.1 Gy ± 0.8 Gy and 26.2 Gy ± 0.6 Gy, respectively. The hippocampus D{sub 100%} mean value was 8.5 Gy ± 0.2 Gy and the maximum dose was 15.7 Gy ± 0.3 Gy. The corresponding plan quality indices were 0.30 ± 0.01 (homogeneity index), 0.94 ± 0.01 (target conformality), and 0.75 ± 0.02 (confirmation number). The median total monitor unit (MU) per fraction was 806 MU (interquartile range [IQR]: 792 to 818 MU) and the average beam total delivery time was 121.2 seconds (IQR: 120.6 to 121.35 seconds). All plans passed the gamma evaluation using the 5-mm, 4% criteria, with γ > 1 of not more than 9.1% data points for all fields. An efficient and simple planning class solution for HA-WBRT using VMAT has been developed that allows all protocol constraints of NRG-CC001 to be met.

  17. Radiative Interaction Between Driver and Driven Gases in an Arc-Driven Shock Tube

    Science.gov (United States)

    Bogdanoff, David W.; Park, Chul

    2001-01-01

    An electric-arc driven shock tube was operated with hydrogen as the driven gas and either hydrogen or helium as the driver gas. Electron density was measured behind the primary shock wave spectroscopically from the width of the Beta line of hydrogen. The measured electron density values were many times greater than the values calculated by the Rankine - Hugoniot relations. By accounting for the radiative transfer from the driver gas to the driven gas, the measured electron density values were numerically recreated.

  18. Simulation of Fault Arc Based on Different Radiation Models in a Closed Tank

    Science.gov (United States)

    Li, Mei; Zhang, Junpeng; Hu, Yang; Zhang, Hantian; Wu, Yifei

    2016-05-01

    This paper focuses on the simulation of a fault arc in a closed tank based on the magneto-hydrodynamic (MHD) method, in which a comparative study of three radiation models, including net emission coefficients (NEC), semi-empirical model based on NEC as well as the P1 model, is developed. The pressure rise calculated by the three radiation models are compared to the measured results. Particularly when the semi-empirical model is used, the effect of different boundary temperatures of the re-absorption layer in the semi-empirical model on pressure rise is concentrated on. The results show that the re-absorption effect in the low-temperature region affects radiation transfer of fault arcs evidently, and thus the internal pressure rise. Compared with the NEC model, P1 and the semi-empirical model with 0.7pressure rise of the fault arc, where is an adjusted parameter involving the boundary temperature of the re-absorption region in the semi-empirical model. supported by National Key Basic Research Program of China (973 Program) (No. 2015CB251002), National Natural Science Foundation of China (Nos. 51221005, 51177124), the Fundamental Research Funds for the Central Universities, the Program for New Century Excellent Talents in University and Shaanxi Province Natural Science Foundation of China (No. 2013JM-7010)

  19. Simulation of Fault Arc Based on Different Radiation Models in a Closed Tank

    Institute of Scientific and Technical Information of China (English)

    LI Mei; ZHANG Junpeng; HU Yang; ZHANG Hantian; WU Yifei

    2016-01-01

    This paper focuses on the simulation of a fault arc in a closed tank based on the magneto-hydrodynamic (MHD) method,in which a comparative study of three radiation models,including net emission coefficients (NEC),semi-empirical model based on NEC as well as the P1 model,is developed.The pressure rise calculated by the three radiation models are compared to the measured results.Particularly when the semi-empirical model is used,the effect of different boundary temperatures of the re-absorption layer in the semi-empirical model on pressure rise is concentrated on.The results show that the re-absorption effect in the low-temperature region affects radiation transfer of fault arcs evidently,and thus the internal pressure rise.Compared with the NEC model,P1 and the semi-empirical model with 0.7 < α < 0.83 are more suitable to calculate the pressure rise of the fault arc,where is an adjusted parameter involving the boundary temperature of the re-absorption region in the semi-empirical model.

  20. Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hae Youn; Seok, Jin Yong; Hong, Joo Wan; Chang, Nam Jun; Choi, Byeong Don; Park, Jin Hong [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Sangnam (Korea, Republic of)

    2015-06-15

    The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and R{sub 50%} was calculated to assess low dose spillage as per treatment plan. D{sub 50%} of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and R{sub 50%} on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum D{sub 50%} was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest

  1. Interaction of graphite and ablative materials with CO2-laser, carbon-arc, and xenon-arc radiation. M.S. Thesis - George Washington Univ., Washington, D. C.

    Science.gov (United States)

    Brewer, W. D.

    1975-01-01

    The behavior of graphite and several charring ablators in a variety of high radiative heat flux environments was studied in various radiative environments produced by a CO2 laser and a carbon arc facility. Graphite was also tested in xenon arc radiation. Tests were conducted in air nitrogen, helium, and a mixture of CO2 and nitrogen, simulating the Venus atmosphere. The experimental results are compared with theoretical results obtained with a one dimensional charring ablator analysis and a two dimensional subliming ablator analysis. Photomicroscopy showed no significant differences in appearance or microstructure of the charring ablators or graphite after testing in the three different facilities, indicating that the materials respond fundamentally the same to the radiation of different frequencies. The performance of phenolic nylon and graphite was satisfactorily predicted with existing analyses and published material property data.

  2. Hazard of ultraviolet radiation emitted in gas tungsten arc welding of aluminum alloys.

    Science.gov (United States)

    Nakashima, Hitoshi; Utsunomiya, Akihiro; Fujii, Nobuyuki; Okuno, Tsutomu

    2016-01-01

    Ultraviolet radiation (UVR) emitted during arc welding frequently causes keratoconjunctivitis and erythema. The extent of the hazard of UVR varies depending on the welding method and conditions. Therefore, it is important to identify the levels of UVR that are present under various conditions. In this study, we experimentally evaluated the hazard of UVR emitted in gas tungsten arc welding (GTAW) of aluminum alloys. The degree of hazard of UVR is measured by the effective irradiance defined in the American Conference of Governmental Industrial Hygienists guidelines. The effective irradiances measured in this study are in the range 0.10-0.91 mW/cm(2) at a distance of 500 mm from the welding arc. The maximum allowable exposure times corresponding to these levels are only 3.3-33 s/day. This demonstrates that unprotected exposure to UVR emitted by GTAW of aluminum alloys is quite hazardous in practice. In addition, we found the following properties of the hazard of UVR. (1) It is more hazardous at higher welding currents than at lower welding currents. (2) It is more hazardous when magnesium is included in the welding materials than when it is not. (3) The hazard depends on the direction of emission from the arc.

  3. Theoretical investigation of coherent synchrotron radiation induced microbunching instability in transport and recirculation arcs

    CERN Document Server

    Tsai, Cheng-Ying; Li, Rui; Tennant, Christopher

    2014-01-01

    The coherent synchrotron radiation (CSR) of a high brightness electron beam traversing a series of dipoles, such as recirculation or transport arcs, may lead to the microbunching instability. We extend and develop a semi-analytical approach of the CSR-induced microbunching instability for a general lattice, based on the previous formulation with 1-D CSR model [Phys. Rev. ST Accel. Beams 5, 064401 (2002)] and apply it to investigate the physical processes of microbunching amplification for two example transport arc lattices. We find that the microbunching instability in transport arcs has a distinguishing feature of multistage amplification (e.g, up to 6th stage for our example arcs in contrast to two stage amplification for a 3-dipole chicane). By further extending the concept of stage gain as proposed by Huang and Kim [Phys. Rev. ST Accel. Beams 5, 074401 (2002)], we developed a method to quantitatively characterize the microbunching amplification in terms of iterative or staged orders that allows the compar...

  4. Investigation in the use of plasma arc welding and alternative feedstock delivery method in additive manufacture

    Science.gov (United States)

    Alhuzaim, Abdullah F.

    The work conducted for this thesis was to investigate the use of plasma arc welding (PAW) and steel shot as a means of additive manufacturing. A robotic PAW system and automatic shot feeder were used to manufacture linear walls approximately 100 mm long by 7 mm wide and 20 mm tall. The walls were built, layer-by-layer, on plain carbon steel substrate by adding individual 2.5 mm diameter plain carbon steel shot. Each layer was built, shot-by-shot, using a pulse of arc current to form a molten pool on the deposit into which each shot was deposited and melted. The deposition rate, a measure of productivity, was approximately 50 g/hour. Three walls were built using the same conditions except for the deposit preheat temperature prior to adding each new layer. The deposit preheat temperature was controlled by allowing the deposit to cool after each layer for an amount of time called the inter-layer wait time. The walls were sectioned and grain size and hardness distribution were measured as a function of wall height. The results indicated that, for all specimens, deposit grain size increased and hardness decreased as wall height increased. Furthermore, average grain size decreased and hardness increased as interlayer wait time increased. An analytical heat flow model was developed to study the influence of interlayer wait time on deposit temperature and therefore grain size and hardness. The results of the model indicated that as wall height increased, the rate of deposit heat removal by conduction to the substrate decreased leading to a higher preheat temperature after a fixed interlayer wait time causing grain size to increase as wall height increased. However, the model results also show that as wall height increased, the deposit surface area from which heat energy is lost via convection and radiation increased. The model also demonstrated that the use of a means of forced convection to rapidly remove heat from the deposit could be an effective way to boost

  5. Change of electrical conductivity of Ar welding arc under resonant absorption of laser radiation

    Science.gov (United States)

    Kozakov, R.; Emde, B.; Pipa, A. V.; Huse, M.; Uhrlandt, D.; Hermsdorf, J.; Wesling, V.

    2015-03-01

    Experimental investigations of the impact of resonant laser absorption by a tungsten inert gas welding arc in argon are presented. The intensity increase of the arc’s radiation between the laser entrance height and the anode are observed, as well as the variation of arc voltage due to the presence of the laser beam. High-speed camera recordings from different directions combined with absolutely calibrated spectroscopic measurements allow the reconstruction of the three-dimensional emission coefficient profiles without the assumption of axial symmetry. The obtained data are evaluated within the framework of local thermodynamic equilibrium. The local increase in the temperature and conductivity due to the influence of the laser is determined. Changes in the electrical conductivity obtained from the optical measurements coincide well with the measured voltage drop, and show significant redistribution of the current density profile near the anode in particular.

  6. Conditions for coherent-synchrotron-radiation-induced microbunching suppression in multibend beam transport or recirculation arcs

    Science.gov (United States)

    Tsai, C.-Y.; Di Mitri, S.; Douglas, D.; Li, R.; Tennant, C.

    2017-02-01

    The coherent synchrotron radiation (CSR) of a high-brightness electron beam traversing a series of dipoles, such as transport or recirculation arcs, may result in beam phase space degradation. On one hand, CSR can perturb electron transverse motion in dispersive regions along the beam line and possibly cause emittance growth. On the other hand, the CSR effect on the longitudinal beam dynamics could result in microbunching instability. For transport arcs, several schemes have been proposed to suppress the CSR-induced emittance growth. Correspondingly, a few scenarios have been introduced to suppress CSR-induced microbunching instability, which however mostly aim for linac-based machines. In this paper we provide sufficient conditions for suppression of CSR-induced microbunching instability along transport or recirculation arcs. Examples are presented with the relevant microbunching analyses carried out by our developed semianalytical Vlasov solver [C.-Y. Tsai, D. Douglas, R. Li, and C. Tennant, Linear microbunching analysis for recirculation machines, Phys. Rev. ST Accel. Beams 19, 114401 (2016), 10.1103/PhysRevAccelBeams.19.114401]. The example lattices include low-energy (˜100 MeV ) and high-energy (˜1 GeV ) recirculation arcs, and medium-energy compressor arcs. Our studies show that lattices satisfying the proposed conditions indeed have microbunching gain suppressed. Beam current dependences of maximal CSR microbunching gains are also demonstrated, which should help outline a beam line design for different scales of nominal currents. We expect this analysis can shed light on the lattice design approach that aims to control the CSR-induced microbunching.

  7. Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jia-Fu [Department of Radiation Physics, Taichung Veterans General Hospital, Taichung, Taiwan (China); Yeh, Dah-Cherng [Department of General Surgery, Taichung Veterans General Hospital, Taichung, Taiwan (China); Yeh, Hui-Ling, E-mail: hlyeh@vghtc.gov.tw [Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung, Taiwan (China); Chang, Chen-Fa [Department of Radiation Physics, Taichung Veterans General Hospital, Taichung, Taiwan (China); Lin, Jin-Ching [Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung, Taiwan (China)

    2015-10-01

    To compare the dosimetric performance of 3 different treatment techniques: hybrid volumetric-modulated arc therapy (hybrid-VMAT), pure-VMAT, and fixed-field intensity-modulated radiation therapy (F-IMRT) for whole-breast irradiation of left-sided early breast cancer. The hybrid-VMAT treatment technique and 2 other treatment techniques—pure-VMAT and F-IMRT—were compared retrospectively in 10 patients with left-sided early breast cancer. The treatment plans of these patients were replanned using the same contours based on the original computed tomography (CT) data sets. Dosimetric parameters were calculated to evaluate plan quality. Total monitor units (MUs) and delivery time were also recorded and evaluated. The hybrid-VMAT plan generated the best results in dose coverage of the target and the dose uniformity inside the target (p < 0.0001 for conformal index [CI]; p = 0.0002 for homogeneity index [HI] of planning target volume [PTV]{sub 50.4} {sub Gy} and p < 0.0001 for HI of PTV{sub 62} {sub Gy}). Volumes of ipsilateral lung irradiated to doses of 20 Gy (V{sub 20} {sub Gy}) and 5 Gy (V{sub 5} {sub Gy}) by the hybrid-VMAT plan were significantly less than those of the F-IMRT and the pure-VMAT plans. The volume of ipsilateral lung irradiated to a dose of 5 Gy was significantly less using the hybrid-VMAT plan than that using the F-IMRT or the pure-VMAT plan. The total mean MUs for the hybrid-VMAT plan were significantly less than those for the F-IMRT or the pure-VMAT plan. The mean machine delivery time was 3.23 ± 0.29 minutes for the hybrid-VMAT plans, which is longer than that for the pure-VMAT plans but shorter than that for the F-IMRT plans. The hybrid-VMAT plan is feasible for whole-breast irradiation of left-sided early breast cancer.

  8. Accuracy of Dose Delivery in Multiple Breath-Hold Segmented Volumetric Modulated Arc Therapy: A Static Phantom Study

    Directory of Open Access Journals (Sweden)

    Kimiya Noto

    2014-01-01

    Full Text Available Purpose. Accuracy of dose delivery in multiple breath-hold segmented volumetric modulated arc therapy (VMAT was evaluated in comparison to noninterrupted VMAT using a static phantom. Material and Methods. Five VMAT plans were evaluated. A Synergy linear accelerator (Elekta AB, Stockholm, Sweden was employed. A VMAT delivery sequence was divided into multiple segments according to each of the predefined breath-hold periods (10, 15, 20, 30, and 40 seconds. The segmented VMAT delivery was compared to noninterrupted VMAT delivery in terms of the isocenter dose and pass rates of a dose difference of 1% with a dose threshold of 10% of the maximum dose on a central coronal plane using a two-dimensional dosimeter, MatriXX Evolution (IBA Dosimetry, Schwarzenbruck, Germany. Results. Means of the isocenter dose differences were 0.5%, 0.2%, 0.2%, 0.0%, and 0.0% for the beam-on-times between interrupts of 10, 15, 20, 30, and 40 seconds, respectively. Means of the pass rates were 85%, 99.9%, 100%, 100%, and 100% in the same order as the above. Conclusion. Our static phantom study indicated that the multiple breath-hold segmented VMAT maintains stable and accurate dose delivery when the beam-on-time between interrupts is 15 seconds or greater.

  9. The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery

    DEFF Research Database (Denmark)

    Falk, Marianne; Larsson, Tobias; Keall, Paul

    2012-01-01

    Purpose: Real-time dynamic multileaf collimator (MLC) tracking for management of intrafraction tumor motion can be challenging for highly modulated beams, as the leaves need to travel far to adjust for target motion perpendicular to the leaf travel direction. The plan modulation can be reduced...... on the dosimetric accuracy of MLC tracking delivery. Specifically, the possibility of predicting the accuracy of MLC tracking delivery based on the plan modulation was investigated. Methods: Inversely optimized arc radiotherapy plans were created on CT-data of three lung cancer patients. For each case, five plans...... with a single 358° arc were generated with LPC priorities of 0 (no LPC), 0.25, 0.5, 0.75, and 1 (highest possible LPC), respectively. All the plans had a prescribed dose of 2 Gy × 30, used 6 MV, a maximum dose rate of 600 MU/min and a collimator angle of 45° or 315°. To quantify the plan modulation, an average...

  10. Clinical application of RapidArc volumetric modulated arc therapy as a component in whole brain radiation therapy for poor prognostic, four or more multiple brain metastases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Heon; Lee, Kyu Chan; Choi, Jin Ho; Kim, Hye Young; Lee, Seok Ho; Sung, Ki Hoon; Kim, Yun Mi [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2012-06-15

    To determine feasibility of RapidArc in sequential or simultaneous integrated tumor boost in whole brain radiation therapy (WBRT) for poor prognostic patients with four or more brain metastases. Nine patients with multiple ({>=}4) brain metastases were analyzed. Three patients were classified as class II in recursive partitioning analysis and 6 were class III. The class III patients presented with hemiparesis, cognitive deficit, or apraxia. The ratio of tumor to whole brain volume was 0.8-7.9%. Six patients received 2-dimensional bilateral WBRT, (30 Gy/10- 12 fractions), followed by sequential RapidArc tumor boost (15-30 Gy/4-10 fractions). Three patients received RapidArc WBRT with simultaneous integrated boost to tumors (48-50 Gy) in 10-20 fractions. The median biologically effective dose to metastatic tumors was 68.1 Gy10 and 67.2 Gy10 and the median brain volume irradiated more than 100 Gy3 were 1.9% (24 cm3) and 0.8% (13 cm3) for each group. With less than 3 minutes of treatment time, RapidArc was easily applied to the patients with poor performance status. The follow-up period was 0.3-16.5 months. Tumor responses among the 6 patients who underwent follow-up magnetic resonance imaging were partial and stable in 3 and 3, respectively. Overall survival at 6 and 12 months were 66.7% and 41.7%, respectively. The local progression-free survival at 6 and 12 months were 100% and 62.5%, respectively. RapidArc as a component in whole brain radiation therapy for poor prognostic, multiple brain metastases is an effective and safe modality with easy application.

  11. Image-guided radiation therapy for treatment delivery and verification

    Science.gov (United States)

    Schubert, Leah Kayomi

    Target conformity and normal tissue sparing provided by modern radiation therapy techniques often result in steep dose gradients, which increase the need for more accurate patient setup and treatment delivery. Image guidance is starting to play a major role in determining the accuracy of treatment setup. A typical objective of image-guided radiation therapy (IGRT) is to minimize differences between planned and delivered treatment by imaging the patient prior to delivery. This step verifies and corrects for patient setup and is referred to as setup verification. This dissertation evaluates the efficacy of daily imaging for setup verification and investigates new uses of IGRT for potential improvements in treatment delivery. The necessity of daily imaging can first be determined by assessing differences in setup corrections between patient groups. Therefore, the first objective of this investigation was to evaluate the application of IGRT for setup verification by quantifying differences in patient positioning for several anatomical disease sites. Detailed analysis of setup corrections for brain, head and neck, lung, and prostate treatments is presented. In this analysis, large setup errors were observed for prostate treatments. Further assessment of prostate treatments was performed, and patient-specific causes of setup errors investigated. Setup corrections are applied via rigid shifts or rotations of the patient or machine, but anatomical deformations occur for which rigid shifts cannot correct. Fortunately, IGRT provides images on which anatomical changes occurring throughout the course of treatment can be detected. From those images, the efficacy of IGRT in ensuring accurate treatment delivery can be evaluated and improved by determining delivered doses and adapting the plan during treatment. The second objective of this dissertation was to explore new applications of IGRT to further improve treatment. By utilizing daily IGRT images, a retrospective analysis of

  12. A treatment-planning comparison of three beam arrangement strategies for stereotactic body radiation therapy for centrally located lung tumors using volumetric-modulated arc therapy

    OpenAIRE

    Ishii, Kentaro; Okada, Wataru; Ogino, Ryo; Kubo, Kazuki; Kishimoto, Shun; Nakahara, Ryuta; Kawamorita, Ryu; Ishii, Yoshie; Tada, Takuhito; Nakajima, Toshifumi

    2016-01-01

    The purpose of this study was to determine appropriate beam arrangement for volumetric-modulated arc therapy (VMAT)-based stereotactic body radiation therapy (SBRT) in the treatment of patients with centrally located lung tumors. Fifteen consecutive patients with centrally located lung tumors treated at our institution were enrolled. For each patient, three VMAT plans were generated using two coplanar partial arcs (CP VMAT), two non-coplanar partial arcs (NCP VMAT), and one coplanar full arc ...

  13. Automated analysis of images acquired with electronic portal imaging device during delivery of quality assurance plans for inversely optimized arc therapy

    DEFF Research Database (Denmark)

    Fredh, Anna; Korreman, Stine; Rosenschöld, Per Munck af

    2010-01-01

    This work presents an automated method for comprehensively analyzing EPID images acquired for quality assurance of RapidArc treatment delivery. In-house-developed software has been used for the analysis and long-term results from measurements on three linacs are presented.......This work presents an automated method for comprehensively analyzing EPID images acquired for quality assurance of RapidArc treatment delivery. In-house-developed software has been used for the analysis and long-term results from measurements on three linacs are presented....

  14. Performance of water and hybrid stabilized electric arcs: the impact of dependence of radiation losses and plasma density on pressure

    Science.gov (United States)

    Jeništa, J.; Bartlová, M.; Aubrecht, V.

    2006-10-01

    Processes in the worldwide unique type of thermal plasma generator with water vortex stabilization and combined stabilization of arc by argon flow and water vortex have been numerically studied. Two-dimensional axisymmetric numerical model assumes laminar and compressible plasma flow in the state of local thermodynamic equilibrium. The calculation domain includes the arc discharge area between the near-cathode region and the outlet nozzle of the plasma torch. Radiation losses from the arc are calculated by the partial characteristics method for atmospheric pressure water and argon-water discharges. Thermal, electrical and fluid-dynamic characteristics of such arcs have been studied for the range of currents 150÷600 A under the assumption that radiation losses and plasma density depend linearly on pressure. It was proved that, taking this dependence into account, plasma velocity decrease while power losses from the arc by radiation and radial conduction increase with current. Outlet plasma temperature as well as electric potential drop remain practically unchanged.

  15. Modeling and Simulation of Radiative Compressible Flows in Aerodynamic Heating Arc-Jet Facility

    Science.gov (United States)

    Bensassi, Khalil; Laguna, Alejandro A.; Lani, Andrea; Mansour, Nagi N.

    2016-01-01

    Numerical simulations of an arc heated flow inside NASA's 20 [MW] Aerodynamics heating facility (AHF) are performed in order to investigate the three-dimensional swirling flow and the current distribution inside the wind tunnel. The plasma is considered in Local Thermodynamics Equilibrium(LTE) and is composed of Air-Argon gas mixture. The governing equations are the Navier-Stokes equations that include source terms corresponding to Joule heating and radiative cooling. The former is obtained by solving an electric potential equation, while the latter is calculated using an innovative massively parallel ray-tracing algorithm. The fully coupled system is closed by the thermodynamics relations and transport properties which are obtained from Chapman-Enskog method. A novel strategy was developed in order to enable the flow solver and the radiation calculation to be preformed independently and simultaneously using a different number of processors. Drastic reduction in the computational cost was achieved using this strategy. Details on the numerical methods used for space discretization, time integration and ray-tracing algorithm will be presented. The effect of the radiative cooling on the dynamics of the flow will be investigated. The complete set of equations were implemented within the COOLFluiD Framework. Fig. 1 shows the geometry of the Anode and part of the constrictor of the Aerodynamics heating facility (AHF). Fig. 2 shows the velocity field distribution along (x-y) plane and the streamline in (z-y) plane.

  16. Effect of high power CO2 and Yb:YAG laser radiation on the characteristics of TIG arc in atmospherical pressure argon and helium

    Science.gov (United States)

    Wu, Shikai; Xiao, Rongshi

    2015-04-01

    The effects of laser radiation on the characteristics of the DC tungsten inert gas (TIG) arc were investigated by applying a high power slab CO2 laser and a Yb:YAG disc laser. Experiment results reveal that the arc voltage-current curve shifts downwards, the arc column expands, and the arc temperature rises while the high power CO2 laser beam vertically interacts with the TIG arc in argon. With the increase of the laser power, the voltage-current curve of the arc shifts downwards more significantly, and the closer the laser beam impingement on the arc to the cathode, the more the decrease in arc voltage. Moreover, the arc column expansion and the arc temperature rise occur mainly in the region between the laser beam incident position and the anode. However, the arc characteristics hardly change in the cases of the CO2 laser-helium arc and YAG laser-arc interactions. The reason is that the inverse Bremsstrahlung absorption coefficients are greatly different due to the different electron densities of the argon and helium arcs and the different wave lengths of CO2 and YAG lasers.

  17. Exploring the limits of spatial resolution in radiation dose delivery.

    Science.gov (United States)

    Otto, Karl; Clark, Brenda G; Huntzinger, Calvin

    2002-08-01

    Flexibility and complexity in patient treatment due to advances in radiotherapy techniques necessitates a simple method for evaluating spatial resolution capabilities of the dose delivery device. Our purpose in this investigation is to evaluate a model that describes the ability of a radiation therapy device to deliver a desired dose distribution. The model is based on linear systems theory and is analogous to methods used to describe resolution degradation in imaging systems. A qualitative analysis of spatial resolution degradation using the model is presented in the spatial and spatial frequency domains. The ability of the model to predict the effects of geometric dose conformity to treatment volumes is evaluated by varying multileaf collimator leaf width and magnitude of dose spreading. Dose distributions for three clinical treatment shapes, circular shapes of varying diameter and one intensity modulated shape are used in the evaluation. We show that the model accurately predicts the dependence of dose conformity on these parameters. The spatial resolution capabilities of different radiation therapy devices can be quantified using the model, providing a simple method for comparing different treatment machine characteristics. Also, as different treatment sites have different resolution requirements this model may be used to tailor machine characteristics to the specific site.

  18. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Katrina, E-mail: Trinabena23@gmail.com; Lenards, Nishele; Holson, Janice

    2016-04-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient's neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient's data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain.

  19. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    Directory of Open Access Journals (Sweden)

    Foroudi Farshad

    2012-07-01

    Full Text Available Abstract Background To compare 3 Dimensional Conformal radiotherapy (3D-CRT with Intensity Modulated Radiotherapy (IMRT with Volumetric-Modulated Arc Therapy (VMAT for bladder cancer. Methods Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Results Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293 for 3D-CRT; 824 (range 641–1083 for IMRT; and 403 (range 333–489 for VMAT (P  Conclusions VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.

  20. Cherenkov imaging during volumetric modulated arc therapy for real-time radiation beam tracking and treatment response monitoring

    Science.gov (United States)

    Andreozzi, Jacqueline M.; Zhang, Rongxiao; Glaser, Adam K.; Gladstone, David J.; Jarvis, Lesley A.; Pogue, Brian W.

    2016-03-01

    External beam radiotherapy utilizes high energy radiation to target cancer with dynamic, patient-specific treatment plans. The otherwise invisible radiation beam can be observed via the optical Cherenkov photons emitted from interaction between the high energy beam and tissue. Using a specialized camera-system, the Cherenkov emission can thus be used to track the radiation beam on the surface of the patient in real-time, even for complex cases such as volumetric modulated arc therapy (VMAT). Two patients undergoing VMAT of the head and neck were imaged and analyzed, and the viability of the system to provide clinical feedback was established.

  1. Trajectory Modulated Arc Therapy: A Fully Dynamic Delivery With Synchronized Couch and Gantry Motion Significantly Improves Dosimetric Indices Correlated With Poor Cosmesis in Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Jieming; Atwood, Todd; Eyben, Rie von; Fahimian, Benjamin; Chin, Erika; Horst, Kathleen [Department of Radiation Oncology, Stanford University, California (United States); Otto, Karl [Department of Physics, University of British Columbia, British Columbia (Canada); Hristov, Dimitre, E-mail: dimitre.hristov@stanford.edu [Department of Radiation Oncology, Stanford University, California (United States)

    2015-08-01

    Purpose: To develop planning and delivery capabilities for linear accelerator–based nonisocentric trajectory modulated arc therapy (TMAT) and to evaluate the benefit of TMAT for accelerated partial breast irradiation (APBI) with the patient in prone position. Methods and Materials: An optimization algorithm for volumetrically modulated arc therapy (VMAT) was generalized to allow for user-defined nonisocentric TMAT trajectories combining couch rotations and translations. After optimization, XML scripts were automatically generated to program and subsequently deliver the TMAT plans. For 10 breast patients in the prone position, TMAT and 6-field noncoplanar intensity modulated radiation therapy (IMRT) plans were generated under equivalent objectives and constraints. These plans were compared with regard to whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose. Results: For TMAT APBI, nonisocentric collision-free horizontal arcs with large angular span (251.5 ± 7.9°) were optimized and delivered with delivery time of ∼4.5 minutes. Percentage changes of whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose for TMAT relative to IMRT were −10.81% ± 6.91%, −27.81% ± 7.39%, −14.82% ± 9.67%, and 39.40% ± 10.53% (P≤.01). Conclusions: This is a first demonstration of end-to-end planning and delivery implementation of a fully dynamic APBI TMAT. Compared with IMRT, TMAT resulted in marked reduction of the breast tissue volume irradiated at high doses.

  2. Formation of Multicharged Metal Ions in Vacuum Arc Plasma Heated by Gyrotron Radiation%Formation of Multicharged Metal Ions in Vacuum Arc Plasma Heated by Gyrotron Radiation

    Institute of Scientific and Technical Information of China (English)

    G. Yu. YUSHKOV; K. P. SAVKIN; A. G. NIKOLAEV; E. M. OKS; A.V. VODOPYANOV; I. V. IZOTOV; D. A. MANSFELD

    2011-01-01

    A new method for the generation of high charged state metal ion beams is developed. This method is based on microwave heating of vacuum arc plasma in a magnetic trap under electron cyclotron resonance (ECR) conditions. Two gyrotrons for plasma heating were used, which were with the following parameters. The first is with a wave frequency of 37.5 GHz, a pulse duration of 1 ms and power of 100 kW, another is with 75 GHz, 0.15 ms and 400 kW. Two different magnetic traps were considered for vacuum arc plasma confinement. The first one is a simple mirror trap. Such system was already investigated and could provide high charge state ions. The second trap was with a cusp magnetic field configuration with native "minimum-B" field structure. Two different ways of metal plasma injection into the magnetic trap were used. The first one is an axial injection from an arc source located out of the trap, and the second is a radial injection from four arc sources mounted at the center of the trap. Both traps provide up to 200 eMA of ion beam current for platinum ions with highest charge state 10+. Ion beams were successfully extracted from the plasma and accelerated by a voltage of up to 20 kV.

  3. Arc Testing of a Mockup Cable in a Simulated Space Radiation Environment

    Science.gov (United States)

    Ferguson, D. C.; Schneider, T. A.; Vaughn, J. A.

    2007-01-01

    A mockup cable was irradiated with electrons of 25-100 keV energy in a vacuum chamber. The m'ockup cable consisted of insulated wires on a kapton substrate, overlaid with a metallized teonex shield. Voltages induced on the wires and shield by the electron beam during irradiation were monitored, and voltage changes were used, along with video, to detect arcs due to the charge built-up in the cable. The cable was also cooled with liquid nitrogen to very low temperatures, to simulate cables kept in the dark for long periods of time. Arcing was common at fluences typical of long space missions. Occasionally an arc would occur some time after the electron beam was turned off. The conductivity of the wires and shield was monitored as a function of temperature, and behaved as expected, with lower conductivities at lower temperatures. Arcs from the wires and shield to ground and from the wires to the shield were measured. Sympathetic arcs were also seen, wherein an arc from the shield to ground or from the wires to ground was followed in a short period of time by another arc of a different type. Implications of these results for real cables on long space missions will be discussed, and recommendations given for arc mitigation.

  4. TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Chin, E; Hoppe, R; Million, L; Loo, B; Koong, A; Xing, L; Hsu, A; Fahimian, B [Stanford University, Stanford, CA (United States); Otto, K [University of British Columbia, Vancouver, BC (Canada)

    2015-06-15

    Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated at 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment

  5. Simulating Proton Synchrotron Radiation in the Arcs of the LHC, HL-LHC, and FCC-hh

    CERN Document Server

    Guillermo Cantón, Gerardo; Zimmermann, Frank

    2016-01-01

    At high proton-beam energies, beam-induced synchrotron radiation is an important source of heating, of beam-related vacuum pressure increase, and of primary photoelectrons, which can give rise to an electron cloud. We use the Synrad3D code developed at Cornell to simulate the photon distributions in the arcs of the LHC, HL-LHC, and FCC-hh. Specifically, for the LHC we study the effect of the “sawtooth” chamber, for the HL-LHC the consequences of the ATS optics with large beta beating in the arcs, and for the FCC-hh the effect of a novel beam-screen design, with a long slit surrounded by a “folded” antechamber.

  6. Dosimetric effects of weight loss or gain during volumetric modulated arc therapy and intensity-modulated radiation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pair, Matthew L. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Du, Weiliang [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Rojas, Hector D.; Kanke, James E.; McGuire, Sean E.; Lee, Andrew K.; Kuban, Deborah A. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J., E-mail: rkudchad@mdanderson.org [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2013-10-01

    Weight loss or gain during the course of radiation therapy for prostate cancer can alter the planned dose to the target volumes and critical organs. Typically, source-to-surface distance (SSD) measurements are documented by therapists on a weekly basis to ensure that patients' exterior surface and isocenter-to-skin surface distances remain stable. The radiation oncology team then determines whether the patient has undergone a physical change sufficient to require a new treatment plan. The effect of weight change (SSD increase or decrease) on intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) dosimetry is not well known, and it is unclear when rescanning or replanning is needed. The purpose of this study was to determine the effects of weight change (SSD increase or decrease) on IMRT or VMAT dose delivery in patients with prostate cancer and to determine the SSD change threshold for replanning. Whether IMRT or VMAT provides better dose stability under weight change conditions was also determined. We generated clinical IMRT and VMAT prostate and seminal vesicle treatment plans for varying SSDs for 10 randomly selected patients with prostate cancer. The differences due to SSD change were quantified by a specific dose change for a specified volume of interest. The target mean dose, decreased or increased by 2.9% per 1-cm SSD decrease or increase in IMRT and by 3.6% in VMAT. If the SSD deviation is more than 1 cm, the radiation oncology team should determine whether to continue treatment without modifications, to adjust monitor units, or to resimulate and replan.

  7. The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance

    Directory of Open Access Journals (Sweden)

    Schreiner L

    2009-01-01

    Full Text Available The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guid-ed radiation therapy (IMRT and IGRT have been limited almost exclusively to linear accel-erators. Investigations of modern Cobalt-60 (Co-60 radiation delivery in the context of IMRT and IGRT have been very sparse, and have been limited mainly to computer-modeling and treatment-planning exercises. In this paper, we report on the results of experiments using a tomotherapy benchtop apparatus attached to a conventional Co-60 unit. We show that conformal dose delivery is possible and also that Co-60 can be used as the radiation source in megavoltage computed tomography imaging. These results complement our modeling studies of Co-60 tomotherapy and provide a strong motivation for continuing development of modern Cobalt-60 treatment devices.

  8. Epid cine acquisition mode for in vivo dosimetry in dynamic arc radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fidanzio, Andrea [U.O. di Fisica Sanitaria Policlinico A. Gemelli, Universita Cattolica S. Cuore, Rome (Italy)], E-mail: andrea.fidanzio@rm.unicatt.it; Mameli, Alessandra; Placidi, Elisa; Greco, Francesca [U.O. di Fisica Sanitaria Policlinico A. Gemelli, Universita Cattolica S. Cuore, Rome (Italy); Stimato, Gerardina; Gaudino, Diego; Ramella, Sara; D' Angelillo, Rolando; Cellini, Francesco; Trodella, Lucio [U.O. di Radioterapia, Universita Campus Bio-Medico, Rome (Italy); Cilla, Savino; Grimaldi, Luca; D' Onofrio, Guido [U.O. di Fisica Sanitaria, Centro di Ricerca e Formazione ad Alta Tecnologia nelle Scienze Biomediche dell' Universita Cattolica S. Cuore, Campobasso (Italy); Azario, Luigi; Piermattei, Angelo [Istituto di Fisica, Universita Cattolica del S. Cuore, Rome (Italy)

    2008-02-15

    In this paper the cine acquisition mode of an electronic portal imaging device (EPID) has been calibrated and tested to determine the in vivo dose for dynamic conformal arc radiation therapy (DCAT). The EPID cine acquisition mode, that allows a frame acquisition rate of one image every 1.66 s, was studied with a monitor unit rate equal to 100 UM/min. In these conditions good signal stability, {+-}1% (2SD) evaluated during three months, signal reproducibility within {+-}0.8% (2SD) and linearity with dose and dose rate within {+-}1% (2SD) were obtained. The transit signal, S{sub t}, (due to the transmitted beam below the phantom) measured by the EPID cine acquisition mode was used to determine, (i) a set of correlation functions, F(w,L), defined as the ratio between S{sub t} and the dose at half thickness, D{sub m}, measured in solid water phantoms of different thicknesses, w and with square fields of side L, (ii) a set of factors, f(d,L), that take into account the different X-ray scatter contribution from the phantom to the S{sub t} signal as a function of the variation, d, of the air gap between the phantom and the EPID. The reconstruction of the isocenter dose, D{sub iso}, for DCAT was obtained convolving the transit signal values, obtained at different gantry angles, with the respective reconstruction factors determined by a house-made software. The method was tested with cylindrical and anthropomorphic phantoms and the results show that the reconstructed D{sub iso} values can be obtained with an accuracy within {+-}2.5% in cylindrical phantom and within {+-}3.4% for anthropomorphic phantom. In conclusion, the transit dosimetry by EPID was assessed to be adequate to perform DCAT in vivo dosimetry, that is not realizable with the other traditional techniques. Moreover, the method proposed here could be implemented to supply in vivo dose values in real time.

  9. Impact of small MU/segment and dose rate on delivery accuracy of volumetric-modulated arc therapy (VMAT).

    Science.gov (United States)

    Huang, Long; Zhuang, Tingliang; Mastroianni, Anthony; Djemil, Toufik; Cui, Taoran; Xia, Ping

    2016-05-08

    Volumetric-modulated arc therapy (VMAT) plans may require more control points (or segments) than some of fixed-beam IMRT plans that are created with a limited number of segments. Increasing number of control points in a VMAT plan for a given prescription dose could create a large portion of the total number of segments with small number monitor units (MUs) per segment. The purpose of this study is to investigate the impact of the small number MU/segment on the delivery accuracy of VMAT delivered with various dose rates. Ten patient datasets were planned for hippocampus sparing for whole brain irradiation. For each dataset, two VMAT plans were created with maximum dose rates of 600 MU/min (the maximum field size of 21 × 40 cm2) and 1000 MU/min (the maximum field size of 15 × 15 cm2) for a daily dose of 3 Gy. Without reoptimization, the daily dose of these plans was purposely reduced to 1.5 Gy and 1.0 Gy while keeping the same total dose. Using the two dose rates and three different daily doses, six VMAT plans for each dataset were delivered to a physical phantom to investigate how the changes of dose rate and daily doses impact on delivery accuracy. Using the gamma index, we directly compared the delivered planar dose profiles with the reduced daily doses (1.5 Gy and 1.0 Gy) to the delivered planar dose at 3 Gy daily dose, delivered at dose rate of 600 MU/min and 1000 MU/min, respectively. The average numbers of segments with MU/segment ≤ 1 were 35 ± 8, 87 ± 6 for VMAT-600 1.5 Gy, VMAT-600 1 Gy plans, and 30 ± 7 and 42 ± 6 for VMAT-1000 1.5 Gy and VMAT-1000 1 Gy plans, respectively. When delivered at 600 MU/min dose rate, the average gamma index passing rates (1%/1 mm criteria) of comparing delivered 1.5 Gy VMAT planar dose profiles to 3.0 Gy VMAT delivered planar dose profiles was 98.28% ± 1.66%, and the average gamma index passing rate of comparing delivered 1.0 Gy VMAT planar dose to 3.0 Gy VMAT delivered planar dose was 83.75% ± 4.86%. If using 2%/2mm

  10. Total Body Irradiation using VMAT (RapidArc: A Planning Study of a novel treatment delivery method

    Directory of Open Access Journals (Sweden)

    Santam Chakraborty

    2015-01-01

    Full Text Available Purpose: To evaluate the feasibility of using volumetric modulated arc therapy (VMAT using RapidArc to deliver total body irradiation (TBI treatment. Methods: VMAT planning was performed a whole body computed tomography (CT data set using Rapid Arc. The planning target volumes included entire body trimmed to 3 mm below the skin. The organs at risk included the lungs and kidneys. A dose of 12 Gy in 10 fractions was prescribed to the target volume. The VMAT-TBI technique consisted of three isocentres and three overlapping arcs: the head and neck, the chest, and the pelvis. The plans were prescribed to ensure, at a minimum, 95% planning target volume dose coverage with the prescription dose (percentage of volume receiving dose of 12 Gy was 95% and maximum dose of 109.8%. Mean dose to lung was restricted at 8.6Gy. Results: The total body volume in the study was 15469cm3 and the PTV volume was 11322cm3. The mean dose to PTV was 104%. The homogeneity index was 0.09. Sparing of normal tissues with adequate coverage of skeletal bones was shown to be feasible with Rapid Arc. The study demonstrates that VMAT is feasible for TBI treatment. Unlike conventional TBI chest wall boost with electrons was not required. Conclusion: The technique for total body irradiation using RapidArc VMAT was found feasible and is undergoing further studies prior to clinical use.

  11. Hypofractionation does not increase radiation pneumonitis risk with modern conformal radiation delivery techniques

    DEFF Research Database (Denmark)

    Vogelius, Ivan R; Westerly, David C; Cannon, George M;

    2010-01-01

    To study the interaction between radiation dose distribution and hypofractionated radiotherapy with respect to the risk of radiation pneumonitis (RP) estimated from normal tissue complication probability (NTCP) models.......To study the interaction between radiation dose distribution and hypofractionated radiotherapy with respect to the risk of radiation pneumonitis (RP) estimated from normal tissue complication probability (NTCP) models....

  12. Which T category of nasopharyngeal carcinoma may benefit most from volumetric modulated arc therapy compared with step and shoot intensity modulated radiation therapy.

    Directory of Open Access Journals (Sweden)

    Ying Sun

    Full Text Available BACKGROUND: To compare volumetric modulated arc therapy (VMAT with conventional step and shoot intensity modulated radiation therapy (s-IMRT in nasopharyngeal carcinoma (NPC patients, and identify which T category patient gains the maximum benefit from VMAT. METHODS: Fifty-two patients that randomly selected from 205 patients received VMAT at a single center were retrospectively replanned with s-IMRT. For a fair comparison, the planning target volume (PTV coverage of the 2 plans was normalized to the same level. A standard planning constraint set was used; the constraints for the organs at risk (OARs were individually adapted. The calculated doses to the PTV and OARs were compared for s-IMRT and VMAT plans generated using the Monaco treatment planning system. RESULTS: VMAT and s-IMRT plans had similar PTV coverage and OAR sparing within all T categories. However, in stratified analysis, VMAT plans lead to better or similar sparing of the OARs in early T category patients; and lead to poorer sparing of the OARs in advanced T category patients (P<0.05. VMAT shows significant advantages for low dose burden (P<0.05 compared with s-IMRT. The delivery time per fraction for VMAT (424±64 s was shorter than s-IMRT (778 ± 126 s, p<0.01. CONCLUSIONS: VMAT provides similar dose coverage of the PTVs and similar/better normal tissue sparing in early T category NPC, and poorer OARs sparing in advanced T category NPC. And VMAT shows significant advantages for low dose burden and delivery time.

  13. Completeness of reporting of radiation therapy planning, dose, and delivery in veterinary radiation oncology manuscripts from 2005 to 2010.

    Science.gov (United States)

    Keyerleber, Michele A; McEntee, Margaret C; Farrelly, John; Podgorsak, Matthew

    2012-01-01

    Surrounding a shift toward evidence-based medicine and widespread adoption of reporting guidelines such as the Consolidated Standards of Reporting Trials (CONSORT) statement, there has been a growing body of literature evaluating the quality of reporting in human and veterinary medicine. These reviews have consistently demonstrated the presence of substantive deficiencies in completeness of reporting. The purpose of this study was to assess the current status of reporting in veterinary radiation oncology manuscripts in regards to treatment planning methods, dose, and delivery and to introduce a set of reporting guidelines to serve as a standard for future reporting. Forty-six veterinary radiation oncology manuscripts published between 2005 and 2010 were evaluated for reporting of 50 items pertaining to patient data, treatment planning, radiation dose, delivery of therapy, quality assurance, and adjunctive therapy. A mean of 40% of checklist items were reported in a given manuscript (range = 8-75%). Only 9/50 (18%) checklist items were reported in > or = 80% manuscripts. The completeness of reporting was best in regards to a statement of prescription radiation protocol (91-98% reported) and worst in regards to specification of absorbed dose within target volumes and surrounding normal tissues (0-6% reported). No manuscripts met the current International Commission of Radiation Units and Measurements (ICRU) dose specification recommendations. Incomplete reporting may stem from the predominance of retrospective manuscripts and the variability of protocols and equipment in veterinary radiation oncology. Adoption of reporting guidelines as outlined in this study is recommended to improve the quality of reporting in veterinary radiation oncology.

  14. Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

    Energy Technology Data Exchange (ETDEWEB)

    Feygelman, Vladimir; Zhang, Geoffrey; Hunt, Dylan; Opp, Daniel [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States); Stambaugh, Cassandra [Department of Physics, University of South Florida, Tampa, Florida 33612 (United States); Wolf, Theresa K. [Live Oak Technologies LLC, Kirkwood, Missouri 63122 (United States); Nelms, Benjamin E. [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States)

    2013-02-15

    Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT

  15. The effect of the target-organ geometric complexity on the choice of delivery between RapidArc and sliding-window IMRT for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kan, Monica W.K., E-mail: kanwkm@ha.org.hk [Department of Oncology, Princess Margaret Hospital, Hong Kong (Hong Kong); Department of Physics and Materials Science, City University of Hong Kong, Kowloon Tong, Hong Kong (Hong Kong); Leung, Lucullus H.T. [Department of Oncology, Princess Margaret Hospital, Hong Kong (Hong Kong); Yu, Peter K.N. [Department of Physics and Materials Science, City University of Hong Kong, Kowloon Tong, Hong Kong (Hong Kong)

    2013-10-01

    We attempted to assess the effect of target-organ geometric complexity on the plan quality of sliding-window intensity-modulated radiotherapy (IMRT), double-arc (RA2), and triple-arc (RA3) RapidArc volumetric-modulated arc radiotherapy for nasopharyngeal carcinoma (NPC). Plans for 9-field sliding-window IMRT, RA2, and RA3 were optimized for 36 patients with NPC ranging from T1 to T4 tumors. Initially the patients were divided into 2 groups, with group A representing the most simple early stage (T1 and T2) cases, whereas group B represented the more complex advanced cases (T3 and T4). Evaluation was performed based on target conformity, target dose homogeneity, organ-sparing capability, and delivery efficiency. Based on the plan quality results, a subgroup of advanced cases, group B2, representing the most demanding task was distinguished and reported separately from the rest of the group B cases, B1. Detailed analysis was performed on the anatomic features for each group of cases, so that planners can easily identify the differences between B1 and B2. For the group A cases, RA3 plans were superior to the IMRT plans in terms of organ sparing, whereas target conformity and dose homogeneity were similar. For the group B1 cases, the RA3 plans produced almost equivalent plan quality as the IMRT plans. For the group B2 cases, for most of which large target volumes were adjacent to (5 mm or less) and wrapping around the brain stem, RA2 and RA3 were inferior to the IMRT regarding both target dose homogeneity and conformity. RA2 plans were slightly inferior to IMRT and RA3 plans for most cases. The plan comparison results depend on the target to brain stem distances and the target sizes. The plan quality results together with the anatomic information may allow the evaluation of the 3 treatment options before actual planning.

  16. Delivery Parameter Variations and Early Clinical Outcomes of Volumetric Modulated Arc Therapy for 31 Prostate Cancer Patients: An Intercomparison of Three Treatment Planning Systems

    Directory of Open Access Journals (Sweden)

    Shinichi Tsutsumi

    2013-01-01

    Full Text Available We created volumetric modulated arc therapy (VMAT plans for 31 prostate cancer patients using one of three treatment planning systems (TPSs—ERGO++, Monaco, or Pinnacle—and then treated those patients. A dose of 74 Gy was prescribed to the planning target volume (PTV. The rectum, bladder, and femur were chosen as organs at risk (OARs with specified dose-volume constraints. Dose volume histograms (DVHs, the mean dose rate, the beam-on time, and early treatment outcomes were evaluated and compared. The DVHs calculated for the three TPSs were comparable. The mean dose rates and beam-on times for Ergo++, Monaco, and SmartArc were, respectively, 174.3 ± 17.7, 149.7 ± 8.4, and 185.8 ± 15.6 MU/min and 132.7 ± 8.4, 217.6 ± 13.1, and 127.5 ± 27.1 sec. During a follow-up period of 486.2 ± 289.9 days, local recurrence was not observed, but distant metastasis was observed in a single patient. Adverse events of grade 3 to grade 4 were not observed. The mean dose rate for Monaco was significantly lower than that for ERGO++ and SmartArc (P<0.0001, and the beam-on time for Monaco was significantly longer than that for ERGO++ and SmartArc (P<0.0001. Each TPS was successfully used for prostate VMAT planning without significant differences in early clinical outcomes despite significant TPS-specific delivery parameter variations.

  17. SU-E-P-14: Dosimetric Effects of Magnetic Field in MRI-Guided Radiation Therapy Delivery for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chen, G; Currey, A; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2015-06-15

    Purpose: MRI-guided radiation therapy (RT) delivery would be beneficial for breast irradiation. The electron return effect due to the presence of a transverse magnetic field (TMF) may cause dosimetric issues on dose on skin and at the lung-tissue interface. The purpose of this study is to investigate these issues. Methods: IMRT plans with tangential beams and VMAT plans with 200 degree arcs to cover ipsilateral breast were generated for 10 randomly selected breast cancer cases using a research planning system (Monaco, Elekta) utilizing Monte Carlo dose calculation with or without a TMF of 1.5 T. Plans were optimized to deliver uniform dose to the whole breast with an exclusion of 5 mm tissue under the skin (PTV-EVAL). All four plans for each patient were re-scaled to have the same PTV-EVAL volume to receive the same prescription dose. The skin is defined as the first 5 mm of ipsilateral-breast tissue, plus extensions in the surrounding region. Results: The presence of 1.5 T TMF resulted in (1)increased skin dose, with the mean and maximum skin dose increase of 5% and 9%, respectively; (2) similar dose homogeneity within the PTV-EVAL; (3) the slightly improved (3%) dose homogeneity in the whole breast; (4) Averages of 9 and 16% increases in V5 and V20, respectively, for ipsilateral lung; and (5) increased the mean heart dose by 34%. VMAT plans don’t improve whole breast dose uniformity as compared that to the tangential plans. Conclusion: The presence of transverse magnetic field in MRI-guided RT delivery for whole breast irradiation can Result in slightly improved dose homogeneity in the whole breast, increased dose to the ipsilateral lung, heart, and skin. Plan optimization with additional specific dose volume constraints may eliminate/reduce these dose increases. This work is partially supported by Elekta Inc.

  18. Direct Plan Comparison of RapidArc and CyberKnife for Spine Stereotactic Body Radiation Therapy

    CERN Document Server

    Choi, Young Eun; Song, Si Yeol; Choi, Eun Kyung; Ahn, Seung Do; Cho, Byungchul

    2015-01-01

    We compared the treatment planning performance of RapidArc (RA) vs. CyberKnife (CK) for spinal stereotactic body radiation therapy (SBRT). Ten patients with spinal lesions who had been treated with CK were re-planned with RA, which consisted of two complete arcs. Computed tomography (CT) and volumetric dose data of CK, generated using the Multiplan (Accuray) treatment planning system (TPS) and the Ray-Trace algorithm, were imported to Varian Eclipse TPS in Dicom format, and the data were compared with the RA plan using analytical anisotropic algorithm (AAA) dose calculation. The optimized dose priorities for both CK and RA plans were similar for all patients. The highest priority was to provide enough dose coverage to the planned target volume (PTV) while limiting the maximum dose to the spinal cord. Plan quality was evaluated with respect to PTV coverage, conformity index (CI), high-dose spillage, intermediate-dose spillage (R50% and D2cm), and maximum dose to the spinal cord, which are criteria recommended ...

  19. Recent Progress in Entry Radiation Measurements in the NASA Ames Electric ARC Shock Tube Facility

    Science.gov (United States)

    Cruden, Brett A.

    2012-01-01

    The Electric Arc Shock Tube (EAST) at NASA Ames Research Center is NASA's only working shock tube capable of obtaining conditions representative of entry in a multitude of planetary atmospheres. The facility is capable of mapping spectroscopic signatures of a wide range of planetary entries from the Vacuum Ultraviolet through Mid-Wave Infrared (120-5500 nm). This paper summarizes the tests performed in EAST for Earth, Mars and Venus entries since 2008, then focuses on a specific test case for CO2/N2 mixtures. In particular, the paper will focus on providing information for the proper interpretation of the EAST data.

  20. Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC leaves for volumetric modulated arc therapy (VMAT

    Directory of Open Access Journals (Sweden)

    Xu Zhengzheng

    2016-03-01

    Full Text Available This study is to report 1 the sensitivity of intensity modulated radiation therapy (IMRT QA method for clinical volumetric modulated arc therapy (VMAT plans with multi-leaf collimator (MLC leaf errors that will not trigger MLC interlock during beam delivery; 2 the effect of non-beam-hold MLC leaf errors on the quality of VMAT plan dose delivery.

  1. SU-E-T-338: Dosimetric Study of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) for Stereotactic Body Radiation Therapy (SBRT) in Early Stage Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I; Quinn, K; Seebach, A; Wang, H [OSF Saint Anthony Medical Center, Rockford, IL (United States); Yah, R [University of Illinois College of Medicine at Rockford, Rockford, IL (United States)

    2015-06-15

    Purpose: This study evaluates the dosimetric differences using volumetric modulated arc therapy (VMAT) in patients previously treated with intensity modulated radiation therapy IMRT for stereotactic body radiotherapy (SBRT) in early stage lung cancer. Methods: We evaluated 9 consecutive medically inoperable lung cancer patients at the start of the SBRT program who were treated with IMRT from November 2010 to October 2011. These patients were treated using 6 MV energy. The 9 cases were then re-planned with VMAT performed with arc therapy using 6 MV flattening filter free (FFF) energy with the same organs at risk (OARS) constraints. Data collected for the treatment plans included target coverage, beam on time, dose to OARS and gamma pass rate. Results: Five patients were T1N0 and four patients were T2N0 with all tumors less than 5 cm. The average GTV was 13.02 cm3 (0.83–40.87) and average PTV was 44.65 cm3 (14.06–118.08). The IMRT plans had a mean of 7.2 angles (6–9) and 5.4 minutes (3.6–11.1) per plan. The VMAT plans had a mean of 2.8 arcs (2–3) and 4.0 minutes (2.2–6.0) per plan. VMAT had slightly more target coverage than IMRT with average increase in D95 of 2.68% (1.24–5.73) and D99 of 3.65% (0.88–8.77). VMAT produced lower doses to all OARs. The largest reductions were in maximum doses to the spinal cord with an average reduction of 24.1%, esophagus with an average reduction of 22.1%, and lung with an average reduction in the V20 of 16.3% The mean gamma pass rate was 99.8% (99.2–100) at 3 mm and 3% for VMAT with comparable values for IMRT. Conclusion: These findings suggest that using VMAT for SBRT in early stage lung cancer is superior to IMRT in terms of dose coverage, OAR dose and a lower treatment delivery time with a similar gamma pass rate.

  2. TH-C-12A-09: Planning and Delivery of the Fully Dynamic Trajectory Modulated Arc Therapy: Application to Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Liang, J; Atwood, T; Fahimian, B; Chin, E; Hristov, D [Department of Radiation Oncology, Stanford University, CA (United States); Otto, K [Department of Physics, University of British Columbia, BC (Canada)

    2014-06-15

    Purpose: A novel trajectory modulated arc therapy (TMAT) system was developed that uses source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement. MLC motion and dose rate were fully optimized for dynamic beam delivery. This work presents a platform for planning deliverable TMAT on a collision free coronal trajectory and evaluates its benefit for accelerated partial breast irradiation (APBI) in a prone position. Methods: The TMAT algorithm was built on VMAT with modifications (physical properties on couch movement were defined) and enhancements (pencil beam dose calculation engine to support extended SSDs) to make it feasible for TMAT delivery. A Matlab software environment for TMAT optimization and dose calculation was created to allow any user specified motion axis. TMAT delivery was implemented on Varian TrueBeamTM STx via XML scripts. 10 prone breast irradiation cases were evaluated in VMAT and compared with a 6- field non-coplanar IMRT plan. Patient selection/exclusion criteria and structure contouring followed the guidelines of NSABP B-39/RTOG 0413 protocol. Results: TMAT delivery time was ∼4.5 minutes. 251.5°±7.88° of non-isocentric couch arc was achieved by the optimized trajectory with 180– 210 control points at 1°–2° couch increments. The improved dose distribution by TMAT was most clearly observed by the marked reduction in the volume of irradiated normal breast tissue in the high dose region. The ratios of the normal breast tissue volume receiving more than 50%, 80% and 100% of the prescription dose for TMAT versus IMRT were: V50%(TMAT/IMRT) = 78.38%±13.03%, V80%(TMAT/IMRT) = 44.19%±9.04% and V100% (TMAT/IMRT) = 9.96%±7.55%, all p≤0.01. Conclusion: The study is the first demonstration of planning and delivery implementation of a fully dynamic APBI TMAT system with continuous couch motion. TMAT achieved significantly improved dosimetry over noncoplanar IMRT on dose volume parameters

  3. WE-D-BRD-01: Innovation in Radiation Therapy Delivery: Advanced Digital Linac Features

    Energy Technology Data Exchange (ETDEWEB)

    Xing, L [Stanford University, Stanford, CA (United States); Wong, J [Johns Hopkins University, Baltimore, MD (United States); Li, R [Stanford University, Palo Alto, CA (United States)

    2014-06-15

    Last few years has witnessed significant advances in linac technology and therapeutic dose delivery method. Digital linacs equipped with high dose rate FFF beams have been clinically implemented in a number of hospitals. Gated VMAT is becoming increasingly popular in treating tumors affected by respiratory motion. This session is devoted to update the audience with these technical advances and to present our experience in clinically implementing the new linacs and dose delivery methods. Topics to be covered include, technical features of new generation of linacs from different vendors, dosimetric characteristics and clinical need for FFF-beam based IMRT and VMAT, respiration-gated VMAT, the concept and implementation of station parameter optimized radiation therapy (SPORT), beam level imaging and onboard image guidance tools. Emphasis will be on providing fundamental understanding of the new treatment delivery and image guidance strategies, control systems, and the associated dosimetric characteristics. Commissioning and acceptance experience on these new treatment delivery technologies will be reported. Clinical experience and challenges encountered during the process of implementation of the new treatment techniques and future applications of the systems will also be highlighted. Learning Objectives: Present background knowledge of emerging digital linacs and summarize their key geometric and dosimetric features. SPORT as an emerging radiation therapy modality specifically designed to take advantage of digital linacs. Discuss issues related to the acceptance and commissioning of the digital linacs and FFF beams. Describe clinical utility of the new generation of digital linacs and their future applications.

  4. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, David, E-mail: d-pasquier@o-lambret.fr [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Centre Galilee, Clinique de la Louviere, Lille (France); Cavillon, Fabrice [Universite Lille Nord de France, Lille (France); Faculte Libre de Medecine, Lille (France); Lacornerie, Thomas [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Touzeau, Claire [Centre Galilee, Clinique de la Louviere, Lille (France); Tresch, Emmanuelle [Unite de Methodologie et Biostatistique, Centre O. Lambret, Lille (France); Lartigau, Eric [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France)

    2013-02-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  5. Direct plan comparison of RapidArc and CyberKnife for spine stereotactic body radiation therapy

    Science.gov (United States)

    Choi, Young Eun; Kwak, Jungwon; Song, Si Yeol; Choi, Eun Kyung; Ahn, Seung Do; Cho, Byungchul

    2015-07-01

    We compared the treatment planning performance of RapidArc (RA) vs. CyberKnife (CK) for spinal stereotactic body radiation therapy (SBRT). Ten patients with spinal lesions who had been treated with CK were re-planned with RA, which consisted of two complete arcs. Computed tomography (CT) and volumetric dose data of CK, generated using the Multiplan (Accuray) treatment planning system (TPS) and the Ray-trace algorithm, were imported to Varian Eclipse TPS in Dicom format, and the data were compared with the RA plan by using an analytical anisotropic algorithm (AAA) dose calculation. The optimized dose priorities for both the CK and the RA plans were similar for all patients. The highest priority was to provide enough dose coverage to the planned target volume (PTV) while limiting the maximum dose to the spinal cord. Plan quality was evaluated with respect to PTV coverage, conformity index (CI), high-dose spillage, intermediate-dose spillage (R50% and D2cm), and maximum dose to the spinal cord, which are criteria recommended by the RTOG 0631 spine and 0915 lung SBRT protocols. The mean CI' SD values of the PTV were 1.11' 0.03 and 1.17' 0.10 for RA and CK ( p = 0.02), respectively. On average, the maximum dose delivered to the spinal cord in CK plans was approximately 11.6% higher than that in RA plans, and this difference was statistically significant ( p systems can create highly conformal volumetric dose distributions, the current study shows that RA demonstrates lower high- and intermediate-dose spillages than CK. Therefore, RA plans for spinal SBRT may be superior to CK plans.

  6. Delivery of 3-5 μm laser radiation by a hollow waveguide

    Science.gov (United States)

    Němec, M.; Jelínková, H.; Miyagi, M.; Iwai, K.; Doroshenko, M.

    2014-04-01

    Radiation delivery is required for various applications—mainly in medicine or industry. Due to the necessity of delivering IR, UV or powerful radiation, its transfer by hollow waveguides was investigated because standard glass fibers cause serious losses. Our special waveguide was based on a fused silica glass capillary tube with an inner silver layer and dielectric film (cyclic olefin polymer (COP)). Three lasers were designed and constructed as mid-infrared sources, namely Er:YAG (2.94 μm), Dy: PbGa2S4 (4.3 μm) and Fe:ZnSe (4.45 μm). The delivered spatial beam profile and transfer capability of 3-5 μm radiation by the COP/Ag hollow glass waveguide were characterized.

  7. Potential for Improved Intelligence Quotient Using Volumetric Modulated Arc Therapy Compared With Conventional 3-Dimensional Conformal Radiation for Whole-Ventricular Radiation in Children

    Energy Technology Data Exchange (ETDEWEB)

    Qi, X. Sharon, E-mail: xqi@mednet.ucla.edu [Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California (United States); Department of Radiation Oncology, University of Colorado Denver, Aurora, Colorado (United States); Stinauer, Michelle; Rogers, Brion [Department of Radiation Oncology, University of Colorado Denver, Aurora, Colorado (United States); Madden, Jennifer R. [Department of Neuro-Oncology, The Children' s Hospital, Aurora, Colorado (United States); Wilkening, Greta N. [Department of Pediatrics, The Children' s Hospital, Aurora, Colorado (United States); Liu, Arthur K. [Department of Radiation Oncology, University of Colorado Denver, Aurora, Colorado (United States)

    2012-12-01

    Purpose: To compare volumetric modulated arc therapy (VMAT) with 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of localized intracranial germinoma. We modeled the effect of the dosimetric differences on intelligence quotient (IQ). Method and Materials: Ten children with intracranial germinomas were used for planning. The prescription doses were 23.4 Gy to the ventricles followed by 21.6 Gy to the tumor located in the pineal region. For each child, a 3D-CRT and full arc VMAT was generated. Coverage of the target was assessed by computing a conformity index and heterogeneity index. We also generated VMAT plans with explicit temporal lobe sparing and with smaller ventricular margin expansions. Mean dose to the temporal lobe was used to estimate IQ 5 years after completion of radiation, using a patient age of 10 years. Results: Compared with the 3D-CRT plan, VMAT improved conformality (conformity index 1.10 vs 1.85), with slightly higher heterogeneity (heterogeneity index 1.09 vs 1.06). The averaged mean doses for left and right temporal lobes were 31.3 and 31.7 Gy, respectively, for VMAT plans and 37.7 and 37.6 Gy for 3D-CRT plans. This difference in mean temporal lobe dose resulted in an estimated IQ difference of 3.1 points at 5 years after radiation therapy. When the temporal lobes were explicitly included in the VMAT optimization, the mean temporal lobe dose was reduced 5.6-5.7 Gy, resulting in an estimated IQ difference of an additional 3 points. Reducing the ventricular margin from 1.5 cm to 0.5 cm decreased mean temporal lobe dose 11.4-13.1 Gy, corresponding to an estimated increase in IQ of 7 points. Conclusion: For treatment of children with intracranial pure germinomas, VMAT compared with 3D-CRT provides increased conformality and reduces doses to normal tissue. This may result in improvements in IQ in these children.

  8. Comparison of rapidArc and fixed field intensity-modulated radiation therapies for advanced nasopharyngeal carcinoma%晚期鼻咽癌RapidArc与固定野调强放疗的比较研究

    Institute of Scientific and Technical Information of China (English)

    庄名赞; 张拓丹; 彭逊; 陈志坚; 林志雄; 李德锐

    2013-01-01

      目的:近年RapidArc的临床应用已引起越来越多的关注,本研究比较RapidArc与固定野调强放射治疗(IMRT)两种放疗技术在晚期鼻咽癌治疗计划中的差异.方法:随机选取10例晚期鼻咽癌患者,采用RapidArc与IMRT两种技术进行计划设计与剂量验证,比较计划的靶区剂量、危及器官与正常组织剂量、机器跳数、治疗时间与剂量验证结果.结果:两种计划的剂量分布基本一致,均能提供足够的靶区剂量.RapidArc的PTVnx最小剂量,PTVnd、PTV60、喉、腮腺的平均剂量低于IMRT,PTV60的HI值高于 IMRT,机器跳数比 IMRT 减少约58%,治疗时间减少约70%.以3%/3mm 为界,RapidArc 验证的γ指数通过率为(98.75±0.50)%,IMRT的通过率为(98.86±0.67)%.结论:两种放疗技术均能够满足临床治疗需要,剂量验证结果能够较好的符合计划计算结果.RapidArc比IMRT有着更多的优势,不仅可以减少机器跳数,缩短治疗时间,而且可以减少喉、腮腺的受照剂量.%Objective: This study compares volumetric-modulated arc therapy (RapidArc) and fixed field intensity-modulated radiation therapy (IMRT) for advanced nasopharyngeal carcinoma. Methods: Ten advanced nasopharyngeal carcinoma patients were randomly selected for this study. Two treatment plans were completed for each patient, i.e., the RapidArc and IMRT schemes. Dosimetric verification was conducted for each scheme. The doses for the planning target volumes (PTVs), organs at risk (OARs), and normal tissues were compared. The technical delivery parameters, including monitor units (MUs), time of therapy, and results of dosimetric verification, were analyzed. Results: No significant differences were found in dose distribution between the two schemes. Both techniques delivered adequate doses for the PTVs. For RapidArc planning, the minimal dose of PTVnx, mean dose of PTVnd, PTV60, larynx, and parotid were lower compared with those of IMRT schemes, whereas the

  9. Preparation and Characterization of Bragg Fibers for Delivery of Laser Radiation at 1064 nm

    Directory of Open Access Journals (Sweden)

    V. Matejec

    2013-04-01

    Full Text Available Bragg fibers offer new performance for transmission of high laser energies over long distances. In this paper theoretical modeling, preparation and characterization of Bragg fibers for delivery laser radiation at 1064 nm are presented. Investigated Bragg fibers consist of the fiber core with a refractive index equal to that of silica which is surrounded by three pairs of circular layers. Each pair is composed of one layer with a high and one layer with a low refractive index and characterized by a refractive-index difference around 0.03. Propagation constants and radiation losses of the fundamental mode in such a structure were calculated on the basis of waveguide optics. Preforms of the Bragg fibers were prepared by the MCVD method using germanium dioxide, phosphorous pentoxide and fluorine as silica dopants. The fibers with a diameter of 170 m were drawn from the preforms. Refractive-index profiles, angular distributions of the output power and optical losses of the prepared fibers were measured. Results of testing the fibers for delivery radiation of a pulse Nd:YAG laser at 1064 nm are also shown.

  10. Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Rachit; Wild, Aaron T.; Ziegler, Mark A.; Hooker, Ted K.; Dah, Samson D.; Tran, Phuoc T.; Kang, Jun; Smith, Koren; Zeng, Jing [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Pawlik, Timothy M. [Department of Surgery, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States); Ford, Eric [Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Seattle, WA (United States); Herman, Joseph M., E-mail: jherma15@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins Hospital, 401N. Broadway, Weinberg Suite 1440, Baltimore, MD 21231 (United States)

    2013-10-01

    Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at

  11. Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Parodi, Katia, E-mail: Katia.parodi@physik.uni-muenchen.de [Faculty of Physics, Department of Medical Physics, Ludwig Maximilians University Munich, Munich 85748 (Germany)

    2015-12-15

    Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy

  12. Air core Bragg fibers for delivery of near-infrared laser radiation

    Science.gov (United States)

    Jelínek, Michal; Frank, Milan; Kubeček, Václav; Matějec, Vlastimil; Kašík, Ivan; Podrazký, Ondřej

    2014-12-01

    Optical fibers designed for high power laser radiation delivery represent important tools in medicine, solar systems, or industry. For such purposes several different types of glass optical fibers such as silica, sapphire, or chalcogenide ones as well as hollow-glass fibers, photonic crystal fibers and Bragg fibers have been investigated. Air-core Bragg fibers or photonic crystal fibers offer us the possibility of light transmission in a low dispersive material - air having a high damage threshold and small non-linear coefficient. However, preforms for drawing Bragg fibers can be fabricated by MCVD method similarly as preforms of standard silica fibers. In this paper we present fundamental characteristics of laboratory-designed and fabricated Bragg fibers with air cores intended for delivery of laser radiation at a wavelength range from 0.9 to 1.5 μm. Bragg fibers with different air core diameters of 5, 45 and 73 mm were prepared. The fiber core was surrounded by three pairs of circular Bragg layers. Each pair was composed of one layer with a high and one layer with a low refractive index with a contrast up to 0.03. Several laser sources emitting at 0.975, 1.06, and 1.55 μm were used as radiation sources. Attenuation coefficients, overall transmissions, bending losses, and spatial profiles of output beams from fibers were determined at these wavelengths. The lowest attenuation coefficient of 70 dB/km was determined for the 45 μm and 73 mm air-core fiber when radiation from a laser was launched into the fibers by using optical lenses. However, multimodal transmission has been observed in such condition. It has also been found that bending losses of such fibers are negligible for bending diameters higher than 15 mm.

  13. Dosimetric Comparison of Volumetric Modulated Arc Therapy, Static Field Intensity Modulated Radiation Therapy, and 3D Conformal Planning for the Treatment of a Right-Sided Reconstructed Chest Wall and Regional Nodal Case

    Directory of Open Access Journals (Sweden)

    Vishruta A. Dumane

    2014-01-01

    Full Text Available We compared 3D conformal planning, static field intensity modulated radiation therapy (IMRT, and volumetric modulated arc therapy (VMAT to investigate the suitable treatment plan and delivery method for a right-sided reconstructed chest wall and nodal case. The dose prescribed for the reconstructed chest wall and regional nodes was 50.4 Gy. Plans were compared for target coverage and doses of the lungs, heart, contralateral breast, and healthy tissue. All plans achieved acceptable coverage of the target and IMNs. The best right lung sparing achieved with 3D was a V20 Gy of 31.09%. Compared to it, VMAT reduced the same by 10.85% and improved the CI and HI over 3D by 18.75% and 2%, respectively. The ipsilateral lung V5 Gy to V20 Gy decreased with VMAT over IMRT by as high as 17.1%. The contralateral lung V5 Gy was also lowered with VMAT compared to IMRT by 16.22%. The MU and treatment beams were lowered with VMAT over IMRT by 30% and 10, respectively, decreasing the treatment time by >50%. VMAT was the treatment plan and delivery method of choice for this case due to a combination of improved lung sparing and reduced treatment time without compromising target coverage.

  14. Prostate Stereotactic Ablative Radiation Therapy Using Volumetric Modulated Arc Therapy to Dominant Intraprostatic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Louise J. [Department of Clinical Oncology, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); University of Leeds, Leeds (United Kingdom); Lilley, John; Thompson, Christopher M.; Cosgrove, Vivian [Department of Medical Physics, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); Mason, Josh [Department of Medical Physics, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); University of Leeds, Leeds (United Kingdom); Sykes, Jonathan [Department of Medical Physics, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); Franks, Kevin [Department of Clinical Oncology, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); Sebag-Montefiore, David [Department of Clinical Oncology, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom); University of Leeds, Leeds (United Kingdom); Henry, Ann M., E-mail: Ann.Henry@leedsth.nhs.uk [Department of Clinical Oncology, Leeds Cancer Centre, St. James' s University Hospital, Leeds (United Kingdom)

    2014-06-01

    Purpose: To investigate boosting dominant intraprostatic lesions (DILs) in the context of stereotactic ablative radiation therapy (SABR) and to examine the impact on tumor control probability (TCP) and normal tissue complication probability (NTCP). Methods and Materials: Ten prostate datasets were selected. DILs were defined using T2-weighted, dynamic contrast-enhanced and diffusion-weighted magnetic resonance imaging. Four plans were produced for each dataset: (1) no boost to DILs; (2) boost to DILs, no seminal vesicles in prescription; (3) boost to DILs, proximal seminal vesicles (proxSV) prescribed intermediate dose; and (4) boost to DILs, proxSV prescribed higher dose. The prostate planning target volume (PTV) prescription was 42.7 Gy in 7 fractions. DILs were initially prescribed 115% of the PTV{sub Prostate} prescription, and PTV{sub DIL} prescriptions were increased in 5% increments until organ-at-risk constraints were reached. TCP and NTCP calculations used the LQ-Poisson Marsden, and Lyman-Kutcher-Burman models respectively. Results: When treating the prostate alone, the median PTV{sub DIL} prescription was 125% (range: 110%-140%) of the PTV{sub Prostate} prescription. Median PTV{sub DIL} D50% was 55.1 Gy (range: 49.6-62.6 Gy). The same PTV{sub DIL} prescriptions and similar PTV{sub DIL} median doses were possible when including the proxSV within the prescription. TCP depended on prostate α/β ratio and was highest with an α/β ratio = 1.5 Gy, where the additional TCP benefit of DIL boosting was least. Rectal NTCP increased with DIL boosting and was considered unacceptably high in 5 cases, which, when replanned with an emphasis on reducing maximum dose to 0.5 cm{sup 3} of rectum (Dmax{sub 0.5cc}), as well as meeting existing constraints, resulted in considerable rectal NTCP reductions. Conclusions: Boosting DILs in the context of SABR is technically feasible but should be approached with caution. If this therapy is adopted, strict rectal

  15. Radiation dose delivery verification in the treatment of carcinoma-cervix

    Energy Technology Data Exchange (ETDEWEB)

    Shrotriya, D., E-mail: shrotriya2007@gmail.com; Srivastava, R. N. L. [Department of Radiotherapy, J.K. Cancer Institute Kanpur-208019 (India); Kumar, S. [Department of Physics, Christ Church College, Kanpur-208001 (India)

    2015-06-24

    The accurate dose delivery to the clinical target volume in radiotherapy can be affected by various pelvic tissues heterogeneities. An in-house heterogeneous woman pelvic phantom was designed and used to verify the consistency and computational capability of treatment planning system of radiation dose delivery in the treatment of cancer cervix. Oncentra 3D-TPS with collapsed cone convolution (CCC) dose calculation algorithm was used to generate AP/PA and box field technique plan. the radiation dose was delivered by Primus Linac (Siemens make) employing high energy 15 MV photon beam by isocenter technique. A PTW make, 0.125cc ionization chamber was used for direct measurements at various reference points in cervix, bladder and rectum. The study revealed that maximum variation between computed and measured dose at cervix reference point was 1% in both the techniques and 3% and 4% variation in AP/PA field and 5% and 4.5% in box technique at bladder and rectum points respectively.

  16. Radiation dose delivery verification in the treatment of carcinoma-cervix

    Science.gov (United States)

    Shrotriya, D.; Kumar, S.; Srivastava, R. N. L.

    2015-06-01

    The accurate dose delivery to the clinical target volume in radiotherapy can be affected by various pelvic tissues heterogeneities. An in-house heterogeneous woman pelvic phantom was designed and used to verify the consistency and computational capability of treatment planning system of radiation dose delivery in the treatment of cancer cervix. Oncentra 3D-TPS with collapsed cone convolution (CCC) dose calculation algorithm was used to generate AP/PA and box field technique plan. the radiation dose was delivered by Primus Linac (Siemens make) employing high energy 15 MV photon beam by isocenter technique. A PTW make, 0.125cc ionization chamber was used for direct measurements at various reference points in cervix, bladder and rectum. The study revealed that maximum variation between computed and measured dose at cervix reference point was 1% in both the techniques and 3% and 4% variation in AP/PA field and 5% and 4.5% in box technique at bladder and rectum points respectively.

  17. Dosimetric comparison of intensity modulated radiation, Proton beam therapy and proton arc therapy for para-aortic lymph node tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon [Dept. of Radiation Oncology, Konyang University Hospital. Daejeon (Korea, Republic of)

    2014-12-15

    To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, D{sub 30%}, D{sub 60%}, D{sub 90%}, V{sub 30%}, V{sub 60%}, V{sub 90}%, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

  18. Locally Targeted Delivery of a Micron-Size Radiation Therapy Source Using Temperature-Sensitive Hydrogel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yusung, E-mail: yusung-kim@uiowa.edu [Department of Radiation Oncology, The University of Iowa, Iowa City, Iowa (United States); Seol, Dong Rim [Department of Orthopaedic Surgery, The University of Iowa, Iowa City, Iowa (United States); Mohapatra, Sucheta [Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa (United States); Sunderland, John J. [Department of Radiology, The University of Iowa, Iowa City, Iowa (United States); Schultz, Michael K. [Department of Radiation Oncology, The University of Iowa, Iowa City, Iowa (United States); Department of Radiology, The University of Iowa, Iowa City, Iowa (United States); Domann, Frederick E. [Department of Radiation Oncology, The University of Iowa, Iowa City, Iowa (United States); Department of Surgery, The University of Iowa, Iowa City, Iowa (United States); Lim, Tae-Hong [Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa (United States)

    2014-04-01

    Purpose: To propose a novel radiation therapy (RT) delivery modality: locally targeted delivery of micron-size RT sources by using temperature-sensitive hydrogel (RT-GEL) as an injectable vehicle. Methods and Materials: Hydrogel is a water-like liquid at room temperature but gels at body temperature. Two US Food and Drug Administration-approved polymers were synthesized. Indium-111 (In-111) was used as the radioactive RT-GEL source. The release characteristics of In-111 from polymerized RT-GEL were evaluated. The injectability and efficacy of RT-GEL delivery to human breast tumor were tested using animal models with control datasets of RT-saline injection. As proof-of-concept studies, a total of 6 nude mice were tested by injecting 4 million tumor cells into their upper backs after a week of acclimatization. Three mice were injected with RT-GEL and 3 with RT-saline. Single-photon emission computed tomography (SPECT) and CT scans were performed on each mouse at 0, 24, and 48 h after injection. The efficacy of RT-GEL was determined by comparison with that of the control datasets by measuring kidney In-111 accumulation (mean nCi/cc), representing the distant diffusion of In-111. Results: RT-GEL was successfully injected into the tumor by using a 30-gauge needle. No difficulties due to polymerization of hydrogel during injection and intratumoral pressure were observed during RT-GEL injection. No back flow occurred for either RT-GEL or RT-saline. The residual tumor activities of In-111 were 49% at 24 h (44% at 48 h, respectively) for RT-GEL and 29% (22%, respectively) for RT-saline. Fused SPECT-CT images of RT-saline showed considerable kidney accumulation of In-111 (2886%, 261%, and 262% of RT-GEL at 0, 24, and 48 h, respectively). Conclusions: RT-GEL was successfully injected and showed much higher residual tumor activity: 170% (200%, respectively), than that of RT-saline at 24 h (48 h, respectively) after injection with a minimal accumulation of In-111 to the

  19. Patient-Specific Quality Assurance for the Delivery of {sup 60}Co Intensity Modulated Radiation Therapy Subject to a 0.35-T Lateral Magnetic Field

    Energy Technology Data Exchange (ETDEWEB)

    Li, H. Harold, E-mail: hli@radonc.wustl.edu; Rodriguez, Vivian L.; Green, Olga L.; Hu, Yanle; Kashani, Rojano; Wooten, H. Omar; Yang, Deshan; Mutic, Sasa

    2015-01-01

    Purpose: This work describes a patient-specific dosimetry quality assurance (QA) program for intensity modulated radiation therapy (IMRT) using ViewRay, the first commercial magnetic resonance imaging-guided RT device. Methods and Materials: The program consisted of: (1) a 1-dimensional multipoint ionization chamber measurement using a customized 15-cm{sup 3} cube-shaped phantom; (2) 2-dimensional (2D) radiographic film measurement using a 30- × 30- × 20-cm{sup 3} phantom with multiple inserted ionization chambers; (3) quasi-3D diode array (ArcCHECK) measurement with a centrally inserted ionization chamber; (4) 2D fluence verification using machine delivery log files; and (5) 3D Monte Carlo (MC) dose reconstruction with machine delivery files and phantom CT. Results: Ionization chamber measurements agreed well with treatment planning system (TPS)-computed doses in all phantom geometries where the mean ± SD difference was 0.0% ± 1.3% (n=102; range, −3.0%-2.9%). Film measurements also showed excellent agreement with the TPS-computed 2D dose distributions where the mean passing rate using 3% relative/3 mm gamma criteria was 94.6% ± 3.4% (n=30; range, 87.4%-100%). For ArcCHECK measurements, the mean ± SD passing rate using 3% relative/3 mm gamma criteria was 98.9% ± 1.1% (n=34; range, 95.8%-100%). 2D fluence maps with a resolution of 1 × 1 mm{sup 2} showed 100% passing rates for all plan deliveries (n=34). The MC reconstructed doses to the phantom agreed well with planned 3D doses where the mean passing rate using 3% absolute/3 mm gamma criteria was 99.0% ± 1.0% (n=18; range, 97.0%-100%), demonstrating the feasibility of evaluating the QA results in the patient geometry. Conclusions: We developed a dosimetry program for ViewRay's patient-specific IMRT QA. The methodology will be useful for other ViewRay users. The QA results presented here can assist the RT community to establish appropriate tolerance and action limits for View

  20. Development of hydrogels by radiation induced polymerization for use in slow drug delivery

    Science.gov (United States)

    Singh, Baljit; Bala, R.

    2014-10-01

    In the present work, in order to improve the drug release profile of indinavir sulfate, a potent inhibitor of HIV protease, controlled drug delivery systems in the form of hydrogels have been designed by a radiation graft polymerization method. These hydrogels have been prepared by using dietary fiber psyllium and binary monomers mixture of acrylamide (AAm) and 2-acrylamido-2-methylpropanesulfonic acid (AMPSA). These polymers have been characterized with cryo-SEMs, FTIR, XRD and swelling studies. The swelling of hydrogels has been determined in solution of different pH, temperature and [NaCl]. in vitro release studies of model drug indinavir sulfate in different pH have been carried out to determine the drug release mechanism. The release of dug occurred through non-Fickian mechanism.

  1. Organisational standards for the delivery of intensity-modulated radiation therapy in Ontario.

    Science.gov (United States)

    Whitton, A; Warde, P; Sharpe, M; Oliver, T K; Bak, K; Leszczynski, K; Etheridge, S; Fleming, K; Gutierrez, E; Favell, L; Green, E

    2009-04-01

    By minimising the effect of irradiation on surrounding tissue, intensity-modulated radiation therapy (IMRT) can deliver higher, more effective doses to the targeted tumour site, minimising treatment-related morbidity and possibly improving cancer control and cure. A multidisciplinary IMRT Expert Panel was convened to develop the organisational standards for the delivery of IMRT. The systematic literature search used MEDLINE, EMBASE, the Cochrane Database, the National Guidelines Clearing House and the Health Technology Assessment Database. An environmental scan of unpublished literature used the Google search engine to review the websites of key organisations, cancer agencies/centres and vendor sites in Canada, the USA, Australia and Europe. In total, 22 relevant guidance documents were identified; 12 from the published literature and 10 from the environmental scan. Professional and organisational standards for the provision of IMRT were developed through the analysis of this evidence and the consensus opinion of the IMRT Expert Panel. The resulting standards address the following domains: planning of new IMRT programmes, practice setting requirements, tools, devices and equipment requirements; professional training requirements; role of personnel; and requirements for quality assurance and safety. Here the IMRT Expert Panel offers organisational and professional standards for the delivery of IMRT, with the intent of promoting innovation, improving access and enhancing patient care.

  2. SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, V; Li, H; Yang, D; Kashani, R; Wooten, H; Mutic, S; Green, O [Washington University School of Medicine, St. Louis, MO (United States); Dempsey, J [ViewRay Incorporated, Oakwood Village, OH (United States)

    2014-06-01

    Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field.

  3. Pretargeting CD45 enhances the selective delivery of radiation to hematolymphoid tissues in nonhuman primates

    Energy Technology Data Exchange (ETDEWEB)

    Green, Damian J.; Pagel, John M.; Nemecek, Eneida R.; Lin, Yukang; Kenoyer, Aimee L.; Pantelias, Anastasia; Hamlin, Donald K.; Wilbur, D. S.; Fisher, Darrell R.; Rajendran, Joseph G.; Gopal, Ajay K.; Park, Steven I.; Press, Oliver W.

    2009-08-06

    Pretargeted radioimmunotherapy (PRIT) is designed to enhance the directed delivery of radionuclides to malignant cells. Through a series of studies in nineteen nonhuman primates (M. fascicularis) the potential therapeutic advantage of anti-CD45 PRIT was evaluated. Anti-CD45 PRIT demonstrated a significant improvement in target-to-normal organ ratios of absorbed radiation when compared to directly radiolabeled bivalent antibody (conventional radioimmunotherapy [RIT]). Radio-DOTA-biotin administered 48 hours after anti-CD45 streptavidin fusion protein (FP) [BC8 (scFv)4SA] produced markedly lower concentrations of radiation in non-target tissues when compared to conventional RIT. PRIT generated superior target:normal organ ratios in the blood, lung and liver (10.3:1, 18.9:1 and 9.9:1 respectively) when compared to the conventional RIT controls (2.6:1, 6.4:1 and 2.9:1 respectively). The FP demonstrated superior retention in target tissues relative to comparable directly radiolabeled bivalent anti-CD45 RIT. The time-point of administration of the second step radiolabeled ligand (radio-DOTA-biotin) significantly impacted the biodistribution of radioactivity in target tissues. Rapid clearance of the FP from the circulation rendered unnecessary the addition of a synthetic clearing agent in this model. These results support proceeding to anti-CD45 PRIT clinical trials for patients with both leukemia and lymphoma.

  4. Synthesis and characterization of psyllium-NVP based drug delivery system through radiation crosslinking polymerization

    Science.gov (United States)

    Singh, Baljit; Kumar, S.

    2008-08-01

    In order to develop the hydrogels meant for the drug delivery, we have prepared psyllium- N-vinylpyrrolidone (NVP) based hydrogels by radiation induced crosslinking. Polymers were characterized with SEMs, FTIR and swelling studies. Swelling of the hydrogels was studied as a function of monomer concentration, total radiation dose, temperature, pH and [NaCl] of the swelling medium. The swelling kinetics of the hydrogels and release dynamics of anticancer model drug (5-fluorouracil) from the hydrogels have been carried out for the evaluation of swelling and drug release mechanism. It has been observed that diffusion exponent ' n' have 0.8, 0.9, 0.8 and gel characteristics constant ' k' have 9.22 × 10 -3, 2.06 × 10 -3, 11.72 × 10 -3 values for the release of drug from the drug loaded hydrogels in distilled water, pH 2.2 buffer and pH 7.4 buffer, respectively. The present study shows that the release of drug from the hydrogels occurred through Non-Fickian diffusion mechanism.

  5. Synthesis and characterization of psyllium-NVP based drug delivery system through radiation crosslinking polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Baljit [Department of Chemistry, Himachal Pradesh University, Shimla 171005 (India)], E-mail: baljitsinghhpu@yahoo.com; Kumar, S. [Department of Chemistry, Himachal Pradesh University, Shimla 171005 (India)

    2008-08-15

    In order to develop the hydrogels meant for the drug delivery, we have prepared psyllium-N-vinylpyrrolidone (NVP) based hydrogels by radiation induced crosslinking. Polymers were characterized with SEMs, FTIR and swelling studies. Swelling of the hydrogels was studied as a function of monomer concentration, total radiation dose, temperature, pH and [NaCl] of the swelling medium. The swelling kinetics of the hydrogels and release dynamics of anticancer model drug (5-fluorouracil) from the hydrogels have been carried out for the evaluation of swelling and drug release mechanism. It has been observed that diffusion exponent 'n' have 0.8, 0.9, 0.8 and gel characteristics constant 'k' have 9.22 x 10{sup -3}, 2.06 x 10{sup -3}, 11.72 x 10{sup -3} values for the release of drug from the drug loaded hydrogels in distilled water, pH 2.2 buffer and pH 7.4 buffer, respectively. The present study shows that the release of drug from the hydrogels occurred through Non-Fickian diffusion mechanism.

  6. WE-EF-BRA-03: Catheter- Free Ablation with External Photon Radiation: Treatment Planning, Delivery Considerations, and Correlation of Effects with Delivered Dose

    Energy Technology Data Exchange (ETDEWEB)

    Deisher, A; Anderson, S; Cusma, J; Herman, M; Johnson, S; Lehmann, H; Packer, D; Parker, K; Song, L; Takami, M; Kruse, J [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: To plan, target, and calculate delivered dose in atrioventricular node (AVN) ablation with volume-modulated arc therapy (VMAT) in an intact porcine model. Methods: Seven pigs underwent AVN irradiation, with prescription doses ranging between 25 and 55Gy in a single fraction. Cardiac CT scans were acquired at expiration. Two physicians contoured AVN targets on 10 phases, providing estimates of target motion and inter-physician variability. Treatment planning was conducted on a static phase-averaged CT. The volume designated to receive prescription dose covered the full extent of AVN cardiac motion, expanded by 4mm for setup uncertainty. Optimization limited doses to risk structures according to single-fraction tumor treatment protocols. Orthogonal kV images were used to align bony anatomy at time of treatment. Localization was further refined with respiratory-gated cone-beam CT, and range of cardiac motion was verified under fluoroscopy. Beam delivery was respiratory-gated for expiration with a mean efficiency of 60%. Deformable registration of the 10 cardiac CT phases was used to calculate actual delivered dose for comparison to electro-anatomical and visually evident lesions. Results: The mean [minimum,maximum] amplitude of AVN cardiac motion was LR 2.9 [1.7,3.9]mm, AP 6.6 [4.4,10.4]mm, and SI 5.6 [2.0,9.9]mm. Incorporating cardiac motion into the dose calculation showed the volume receiving full dose was 40–80% of the volume indicated on the static planning image, although the contoured AVN target received full dose in all animals. Initial results suggest the dimensions of the electro-anatomical lesion are correlated with the 40Gy isodose volume. Conclusion: Image-guidance techniques allow for accurate and precise delivery of VMAT for catheter-free arrhythmia ablation. An arsenal of advanced radiation planning, dose optimization, and image-guided delivery techniques was employed to assess and mitigate effects of cardiac and respiratory motion

  7. Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial

    DEFF Research Database (Denmark)

    Colvill, Emma; Booth, Jeremy T; O'Brien, Ricky T;

    2015-01-01

    PURPOSE: To test the hypothesis that multileaf collimator (MLC) tracking improves the consistency between the planned and delivered dose compared with the dose without MLC tracking, in the setting of a prostate cancer volumetric modulated arc therapy trial. METHODS AND MATERIALS: Multileaf...... collimator tracking was implemented for 15 patients in a prostate cancer radiation therapy trial; in total, 513 treatment fractions were delivered. During each treatment fraction, the prostate trajectory and treatment MLC positions were collected. These data were used as input for dose reconstruction...

  8. SU-E-T-248: Near Real-Time Analysis of Radiation Delivery and Imaging, Accuracy to Ensure Patient Safety

    Energy Technology Data Exchange (ETDEWEB)

    Wijesooriya, K; Seitter, K; Desai, V; Read, P; Larner, J [University of Virginia Health Systems, Charlottesville, VA (United States)

    2014-06-01

    Purpose: To develop and optimize an effective software method for comparing planned to delivered control point machine parameters for all VARIAN TrueBeam treatments so as to permit (1) assessment of a large patient pool throughout their treatment course to quantify treatment technique specific systematic and random uncertainty of observables, (2) quantify the site specific daily imaging shifts required for target alignment, and (3) define tolerance levels for mechanical parameters and imaging parameters based on statistical analysis data gathered, and the dosimetric impact of variations. Methods: Treatment and imaging log files were directly compared to plan parameters for Eclipse and Pinnacle planned treatments via 3D, IMRT, control point, RapidArc, and electrons. Each control point from all beams/arcs (7984) for all fractions (1940) of all patients treated over six months were analyzed. At each control point gantry angle, collimator angle, couch angle, jaw positions, MLC positions, MU were compared. Additionally per-treatment isocenter shifts were calculated. Results were analyzed as a whole in treatment type subsets: IMRT, 3D, RapidArc; and in treatment site subsets: brain, chest/mediastinum, esophagus, H and N, lung, pelvis, prostate. Results: Daily imaging isocenter shifts from initial external tattoo alignment were dependent on the treatment site with < 0.5 cm translational shifts for H and N, Brain, and lung SBRT, while pelvis, esophagus shifts were ∼1 cm. Mechanical delivery parameters were within tolerance levels for all sub-beams. The largest variations were for RapidArc plans: gantry angle 0.11±0.12,collimator angle 0.00±0.00, jaw positions 0.48±0.26, MLC leaf positions 0.66±0.08, MU 0.14±0.34. Conclusion: Per-control point validation reveals deviations between planned and delivered parameters. If used in a near real-time error checking system, patient safety can be improved by equipping the treatment delivery system with additional forcing

  9. The geometric calibration of cone-beam imaging and delivery systems in radiation therapy

    CERN Document Server

    Matsinos, E; Kaissl, Wolfgang; Matsinos, Evangelos

    2006-01-01

    We propose a method to achieve the geometric calibration of cone-beam imaging and delivery systems in radiation therapy; our approach applies to devices where an X-ray source and a flat-panel detector, facing each other, move in circular orbits around the irradiated object. In order to extract the parameters of the geometry from the data, we use a light needle phantom which is easy to manufacture. A model with ten free parameters (spatial lengths and distortion angles) has been put forth to describe the geometry and the mechanical imperfections of the units being calibrated; a few additional parameters are introduced to account for residual effects (small effects which lie beyond our model). The values of the model parameters are determined from one complete scan of the needle phantom via a robust optimisation scheme. The application of this method to two sets of five counterclockwise (ccw) and five clockwise (cw) scans yielded consistent and reproducible results. A number of differences have been observed be...

  10. Radiation-Guided Peptide Delivery in a Mouse Model of Nasopharyngeal Carcinoma

    Directory of Open Access Journals (Sweden)

    Pei-cheng Lin

    2016-01-01

    Full Text Available Purpose. This study aimed to evaluate the characteristics of the HVGGSSV peptide, exploring radiation-guided delivery in a mouse model of nasopharyngeal carcinoma. Methods. Mice with CNE-1 nasopharyngeal carcinoma were assigned to two different groups treated with Cy7-NHS and Cy7-HVGGSSV, respectively. Meanwhile, each mouse received a single dose of 3 Gy radiation. Biological distribution of the recombinant peptide was assessed on an in vivo small animal imaging system. Results. The experimental group showed maximum fluorescence intensity in irradiated tumors treated with Cy7-labeled HVGGSSV, while untreated (0 Gy control tumors showed lower intensity levels. Fluorescence intensities of tumors in the right hind limbs of experimental animals were 7.84×107±1.13×107, 1.35×108±2.66×107, 4.05×108±1.75×107, 5.57×108±3.47×107, and 9.26×107±1.73×107 photons/s/cm2 higher compared with left hind limb values at 1, 2, 15, 24, and 48 h, respectively. Fluorescence intensities of tumor in the right hind limbs of the experimental group were 1.66×108±1.71×107, 1.51×108±3.23×107, 5.38×108±1.96×107, 5.89×108±3.57×107, and 1.62×108±1.69×107 photons/s/cm2 higher compared with control group values at 1, 2, 15, 24, and 48 h, respectively. Fluorescence was not specifically distributed in the control group. Compared with low fluorescence intensity in the heart, lungs, and tumors, high fluorescence distribution was found in the liver and kidney at 48 h. Conclusions. HVGGSSV was selectively bound to irradiated nasopharyngeal carcinoma, acting as a targeting transport carrier for radiation-guided drugs that are mainly metabolized in the kidney and liver.

  11. Radiation-Guided Peptide Delivery in a Mouse Model of Nasopharyngeal Carcinoma

    Science.gov (United States)

    Lin, Pei-cheng; He, Jun-yan; Le, Yu-yin; Du, Kai-xin; Zhu, Wei-feng; Peng, Qing-qin; Dong, Ya-ping

    2016-01-01

    Purpose. This study aimed to evaluate the characteristics of the HVGGSSV peptide, exploring radiation-guided delivery in a mouse model of nasopharyngeal carcinoma. Methods. Mice with CNE-1 nasopharyngeal carcinoma were assigned to two different groups treated with Cy7-NHS and Cy7-HVGGSSV, respectively. Meanwhile, each mouse received a single dose of 3 Gy radiation. Biological distribution of the recombinant peptide was assessed on an in vivo small animal imaging system. Results. The experimental group showed maximum fluorescence intensity in irradiated tumors treated with Cy7-labeled HVGGSSV, while untreated (0 Gy) control tumors showed lower intensity levels. Fluorescence intensities of tumors in the right hind limbs of experimental animals were 7.84 × 107 ± 1.13 × 107, 1.35 × 108 ± 2.66 × 107, 4.05 × 108 ± 1.75 × 107, 5.57 × 108 ± 3.47 × 107, and 9.26 × 107 ± 1.73 × 107 photons/s/cm2 higher compared with left hind limb values at 1, 2, 15, 24, and 48 h, respectively. Fluorescence intensities of tumor in the right hind limbs of the experimental group were 1.66 × 108 ± 1.71 × 107, 1.51 × 108 ± 3.23 × 107, 5.38 × 108 ± 1.96 × 107, 5.89 × 108 ± 3.57 × 107, and 1.62 × 108 ± 1.69 × 107 photons/s/cm2 higher compared with control group values at 1, 2, 15, 24, and 48 h, respectively. Fluorescence was not specifically distributed in the control group. Compared with low fluorescence intensity in the heart, lungs, and tumors, high fluorescence distribution was found in the liver and kidney at 48 h. Conclusions. HVGGSSV was selectively bound to irradiated nasopharyngeal carcinoma, acting as a targeting transport carrier for radiation-guided drugs that are mainly metabolized in the kidney and liver.

  12. Impact of prolonged fraction dose-delivery time modeling intensity-modulated radiation therapy on hepatocellular carcinoma cell killing

    Institute of Scientific and Technical Information of China (English)

    Xiao-Kang Zheng; Long-Hua Chen; Xiao Yan; Hong-Mei Wang

    2005-01-01

    AIM: To explore the impact of prolonged fraction dosedelivery time modeling intensity-modulated radiation therapy (IMRT) on cell killing of human hepatocellular carcinoma (HCC) HepG2 and Hep3B cell lines.METHODS: The radiobiological characteristics of human HCC HepG2 and Hep3b cell lines were studied with standard clonogenic assays, using standard linear-quadratic model and incomplete repair model to fit the dose-survival curves. The identical methods were also employed to investigate the biological effectiveness of irradiation protocols modeling clinical conventional fractionated external beam radiotherapy (EBRT, fraction delivery time 3 min) and IMRT with different prolonged fraction delivery time (15, 30, and 45 min). The differences of cell surviving fraction irradiated with different fraction delivery time were tested with paired t-test. Factors determining the impact of prolonged fraction delivery time on cell killing were analyzed.RESULTS: The α/β and repair half-time (T1/2) of HepG2and Hep3b were 3.1 and 7.4 Gy, and 22 and 19 min respectively. The surviving fraction of HepG2 irradiated modeling IMRT with different fraction delivery time was significantly higher than irradiated modeling EBRT and the cell survival increased more pronouncedly with the fraction delivery time prolonged from 15 to 45 min,while no significant differences of cell survival in Hep3b were found between different fraction delivery time protocols.CONCLUSION: The prolonged fraction delivery time modeling IMRT significantly decreased the cell killing in HepG2 but not in Hep3b. The capability of sub-lethal damage repair was the predominant factor determining the cell killing decrease. These effects, if confirmed by clinical studies, should be considered in designing IMRT treatments for HCC.

  13. Pilot Study of the Delivery of Microcollimated Pars Plana External Beam Radiation in Porcine Eyes: 270-Day Analysis

    Directory of Open Access Journals (Sweden)

    Rishi P. Singh

    2012-01-01

    Full Text Available Objective. To determine the dose response and toxicity threshold of micro-collimated X-rays delivered to porcine maculae by a stereotactic radiosurgical system after 270 days. Methods. Twelve eyes of six Yucatan mini-swine were randomized to receive up to 90 Gy to the retina, using an office-based trans-pars plana delivery system. To determine the safety profile of this radiation delivery, ophthalmic examination, fundus photography, fluorescein angiography (FA, and spectral domain optical coherence tomography (SD-OCT were obtained at multiple time points up to 270 days post treatment. Results. No abnormalities were noted on external examination. Cataracts were noted in 4 of 12 eyes. Dose and time-dependent changes were noted on fundus examination, FA, ICG and SD-OCT. No significant abnormalities were seen in the control, 16 Gy or 24 Gy groups using any modality. Histopathology revealed a dose response effect with no discernable lesions in the 16 Gy group. Conclusion. The X-ray delivery system precisely targets the porcine retina in vivo with little effect on surrounding structures. No ophthalmic or intracranial adverse effects were noted at clinically relevant doses at 270 days following radiation delivery.

  14. Treatment planning for volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bedford, James L. [Joint Department of Physics, Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

    2009-11-15

    Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

  15. Cathodic arcs

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre

    2003-10-29

    Cathodic arc plasma deposition has become the technology of choice for hard, wear and corrosion resistant coatings for a variety of applications. The history, basic physics of cathodic arc operation, the infamous macroparticle problem and common filter solutions, and emerging high-tech applications are briefly reviewed. Cathodic arc plasmas standout due to their high degree of ionization, with important consequences for film nucleation, growth, and efficient utilization of substrate bias. Industrial processes often use cathodic arc plasma in reactive mode. In contrast, the science of arcs has focused on the case of vacuum arcs. Future research directions include closing the knowledge gap for reactive mode, large area coating, linear sources and filters, metal plasma immersion process, with application in high-tech and biomedical fields.

  16. Cathodic arcs

    OpenAIRE

    Anders, Andre

    2003-01-01

    Cathodic arc plasma deposition has become the technology of choice for hard, wear and corrosion resistant coatings for a variety of applications. The history, basic physics of cathodic arc operation, the infamous macroparticle problem and common filter solutions, and emerging high-tech applications are briefly reviewed. Cathodic arc plasmas stand out due to their high degree of ionization, with important consequences for film nucleation, growth, and efficient utilization of substrate bia...

  17. SU-E-T-633: Preparation and Planning of a VMAT Multi - Arc Radiation Therapy Technique for Full Scalp Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, C; Bardock, A; Berkelaar, S; Gillund, D; McGee, K; Mohamed, I; Lapointe, C [British Columbia Cancer Agency, Kelowna, BC (Canada)

    2015-06-15

    Purpose: The target volume for angiosarcoma of the scalp encompasses the entire scalp. Full scalp radiotherapy (FSRT) requires careful design of required bolus, immobilization and marking of the field before the patient CT is acquired. A VMAT multi-arc technique was designed to deliver FSRT for a patient with angiosarcoma of the scalp to a dose of 6000cGy in 25 fractions. Methods: A custom bolus helmet was fabricated from a 0.5 cm thick sheet of aquaplast material, which was molded to the patient’s head. With the bolus helmet in place the patient was then positioned supine on a H&N immobilization board. A custom vaclock bag positioned on a standard headrest and a thermoplastic mask were used to immobilize the patient. Additional bolus to cover the remaining treatment area was attached to the mask. We acquired two CT scans of the patient’s head, one in treatment position and an additional scan without the immobilization mask with wires marking the treatment area that the oncologist had delineated on the patient’s skin. The second scan was registered to the first and used to define the treatment CTV. A four-arc VMAT treatment planned using Varian-Eclipse was optimized to cover the skin with a PTV margin while sparing the brain and limiting the dose to the optic apparatus and lacrimal glands. Daily treatment setup was verified using anterior and lateral kV on-board-imaging. To verify the treated dose, TLDs were positioned on the patient’s scalp during one fraction. Results: With full dose coverage to the PTV, the mean dose to the brain was less than 24 Gy. The dose measured by the TLDs (mean difference 1%, standard deviation 4%)showed excellent agreement with the treatment planning calculation. Conclusion: FSRT delivered with a bolus helmet and a VMAT multi-arc technique can be accurately delivered with high dose uniformity and conformality.

  18. Whole abdomen radiation therapy in ovarian cancers: a comparison between fixed beam and volumetric arc based intensity modulation

    Directory of Open Access Journals (Sweden)

    Clivio Alessandro

    2010-11-01

    Full Text Available Abstract Purpose A study was performed to assess dosimetric characteristics of volumetric modulated arcs (RapidArc, RA and fixed field intensity modulated therapy (IMRT for Whole Abdomen Radiotherapy (WAR after ovarian cancer. Methods and Materials Plans for IMRT and RA were optimised for 5 patients prescribing 25 Gy to the whole abdomen (PTV_WAR and 45 Gy to the pelvis and pelvic nodes (PTV_Pelvis with Simultaneous Integrated Boost (SIB technique. Plans were investigated for 6 MV (RA6, IMRT6 and 15 MV (RA15, IMRT15 photons. Objectives were: for both PTVs V90% > 95%, for PTV_Pelvis: Dmax Results IMRT and RapidArc resulted comparable for target coverage. For PTV_WAR, V90% was 99.8 ± 0.2% and 93.4 ± 7.3% for IMRT6 and IMRT15, and 98.4 ± 1.7 and 98.6 ± 0.9% for RA6 and RA15. Target coverage resulted improved for PTV_Pelvis. Dose homogeneity resulted slightly improved by RA (Uniformity was defined as U5-95% = D5%-D95%/Dmean. U5-95% for PTV_WAR was 0.34 ± 0.05 and 0.32 ± 0.06 (IMRT6 and IMRT15, 0.30 ± 0.03 and 0.26 ± 0.04 (RA6 and RA15; for PTV_Pelvis, it resulted equal to 0.1 for all techniques. For organs at risk, small differences were observed between the techniques. MU resulted 3130 ± 221 (IMRT6, 2841 ± 318 (IMRT15, 538 ± 29 (RA6, 635 ± 139 (RA15; the average measured treatment time was 18.0 ± 0.8 and 17.4 ± 2.2 minutes (IMRT6 and IMRT15 and 4.8 ± 0.2 (RA6 and RA15. GAIIMRT6 = 97.3 ± 2.6%, GAIIMRT15 = 94.4 ± 2.1%, GAIRA6 = 98.7 ± 1.0% and GAIRA15 = 95.7 ± 3.7%. Conclusion RapidArc showed to be a solution to WAR treatments offering good dosimetric features with significant logistic improvements compared to IMRT.

  19. SU-E-T-426: Feasibility of Stereotactic Body Radiation Therapy (SBRT) Treatment of Pancreatic Cancer Using Volumetric Modulated Arc Therapy (VMAT) with Active Breathing Control (ABC)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y; Jackson, J; Davies, G; Herman, J; Forbang, R Teboh [John Hopkins University, Baltimore, MD (United States)

    2015-06-15

    Purpose: SBRT shows excellent tumor control and toxicity rates for patients with locally advanced pancreatic cancer (PCA). Herein, we evaluate the feasibility of using VMAT with ABC for PCA SBRT. Methods: Nine PCA patients previously treated via SBRT utilizing 11-beam step-and-shoot IMRT technique in our center were retrospectively identified, among whom eight patients received 3300cGy in 5 fractions while one received 3000cGy in 5 fractions. A VMAT plan was generated on each patient’s planning CT in Pinnacle v9.8 on Elekta Synergy following the same PCA SBRT clinical protocol. Three partial arcs (182°–300°, 300°-60°, and 60°-180°) with 2°/4° control-point spacing were used. The dosimetric difference between the VMAT and the original IMRT plans was analyzed. IMRT QA was performed for the VMAT plans using MapCheck2 in MapPHAN and the total delivery time was recorded. To mimic the treatment situation with ABC, where patients hold their breath for 20–30 seconds, the delivery was intentionally interrupted every 20–30 seconds. For each plan, the QA was performed with and without beam interruption. Gamma analysis (2%/2mm) was used to compare the planned and measured doses. Results: All VMAT plans with 2mm dose grid passed the clinic protocol with similar PTV coverage and OARs sparing, where PTV V-RxDose was 92.7±2.1% (VMAT) vs. 92.1±2.6% (IMRT), and proximal stomach V15Gy was 3.60±2.69 cc (VMAT) vs. 4.80±3.13 cc (IMRT). The mean total MU and delivery time of the VMAT plans were 2453.8±531.1 MU and 282.1±56.0 seconds. The gamma passing rates of absolute dose were 94.9±3.4% and 94.5±4.0% for delivery without and with interruption respectively, suggesting the dosimetry of VMAT delivery with ABC for SBRT won’t be compromised. Conclusion: This study suggests that PCA SBRT using VMAT with ABC is a feasible technique without compromising plan dosimetry. The combination of VMAT with ABC will potentially reduce the SBRT treatment time.

  20. Chronic exposure to the ultraviolet radiation levels from arc welding does not result in obvious damage to the human corneal endothelium.

    Science.gov (United States)

    Oblak, Emil; Doughty, Michael J

    2002-11-01

    Occupational exposure of the cornea to ultraviolet radiation (UVR, e.g. in welding) is a well-known cause of 'arc eye' (photo-keratoconjunctivitis), but has also been considered to be a risk for the development of alterations in the size (polymegethism) and shape (pleomorphism) of the deeper-lying human corneal endothelial cells. Human data are however limited and so a further study was undertaken, with a control group. Non-contact specular micrographs of the central region of the corneal endothelium were obtained from 40 white males aged between 32 and 63 years; 20 were arc welders with an average of 25 +/- 7 years job experience, while the others were office workers (n = 20). All the welders reported occupational exposure to UVR (i.e. welders 'flashes') and up to 3 times per year. None of the subjects had a history of contact lens wear, major eye disease or surgery. The endothelial image was scanned, projected onto an overlay and cell border marking carried out in a masked fashion. The overlay was independently analysed, by a customised semi-automated method, providing cell-border-adjusted data on cell areas and cell shape (sides) on 124 to 260 cells per image. The endothelial cell density (ECD) values were also calculated from individual cell area values. All corneas appeared to be healthy, and showed no fluorescein staining indicating damage to the surface epithelium. Central corneal thickness values were normal at 0.531 +/- 0.031 (mean +/- SD) and 0.527 +/- 0.036 mm in the welders and non-welders respectively. All endothelia appeared healthy, with no evidence of cell oedema. The group-mean endothelial cell area was 393 +/- 35 and 392 +/- 21 microm2, ECD values were 2855 +/- 224 cells mm(-2) and 2852 +/- 210 cells mm(-2), while the percentages of 6-sided cells were 60 +/- 5.2 and 59 +/- 4.1% respectively. Cell area distributions were statistically identical (p > or = 0.8), and cell area-side relationships were marginally, but not statistically different. This

  1. Welding arc radiation hazard and protection%电弧焊弧光幅射的危害与防护

    Institute of Scientific and Technical Information of China (English)

    欧泽兵

    2011-01-01

    在分析焊接产生的紫外线、可见光和红外线辐射特点及其危害的基础上,依据标准要求提出防护装备的使用要求以及通过培训以提高焊接操作者自我防护意识的建议,从而最大限度地减少焊接弧光对焊接操作者的危害.%The paper presents suggestion on welding hazards protection based on characteristics of UV.IR,visible lights and related standards.To minimize welding arc hazards via improving welders' safety consciousness by hazards analysis and protection training.

  2. SU-E-T-625: Potential for Reduced Radiation Induced Toxicity for the Treatment of Inoperable Non-Small-Cell Lung Cancer Using RapidArc Planning

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, D; Sood, S; Badkul, R; Jiang, H; Saleh, H; Wang, F [University of Kansas Hospital, Kansas City, KS (United States)

    2015-06-15

    Purpose: To investigate the feasibility of using RapidArc (RA) treatment planning to reduce irradiation volume of normal lung and other organs at risk (OARs) in the treatment of inoperable non-small-cell lung cancer (NSCLC) patients. Methods: A retrospective treatment planning and delivery study was performed to compare target coverage and the volumes of the normal lung, spinal cord, heart and esophagus on 4D-CT scan above their dose tolerances delivered by RA vs. IMRT for ten inoperable NSCLC patients (Stage I-IIIB). RA plans consisted of either one-full or two-partial co-planar arcs used to treat 95% of the planning target volume (PTV) with 6MV beam to a prescription of 66Gy in 33 fractions. IMRT plans were generated using 5–7 co-planar fields with 6MV beam. PTV coverage, dose-volume histograms, homogeneity/conformity indices (CI), total number of monitor units(MUs), beam-on time and delivery accuracy were compared between the two treatment plans. Results: Similar target coverage was obtained between the two techniques. RA (CI=1.02) provided more conformal plans without loss of homogeneity compared to IMRT plans (CI=1.12). Compared to IMRT, RA achieved a significant median dose reduction in V10 (3%), V20 (8%), and mean lung dose (3%) on average, respectively. On average, V5 was comparable between the two treatment plans. RA reduced mean esophagus (6%), mean heart (18%), and maximum spinal cord dose (7%), on average, respectively. Total number of MUs and beam-on time were each reduced almost by a factor of 2 when compared to IMRT-patient comfort, reduced intra-fraction-motion and leakage dose. The average IMRT and RA QA pass rate was about 98% for both types of plans for 3%/3mm criterion. Conclusion: Compared to IMRT plans, RA provided not only comparable target coverage, but also improved conformity, treatment time, and significant reduction in irradiation of OARs. This may potentially allow for target dose escalation without increase in normal tissue toxicity.

  3. Arc Plasma Torch Modeling

    CERN Document Server

    Trelles, J P; Vardelle, A; Heberlein, J V R

    2013-01-01

    Arc plasma torches are the primary components of various industrial thermal plasma processes involving plasma spraying, metal cutting and welding, thermal plasma CVD, metal melting and remelting, waste treatment and gas production. They are relatively simple devices whose operation implies intricate thermal, chemical, electrical, and fluid dynamics phenomena. Modeling may be used as a means to better understand the physical processes involved in their operation. This paper presents an overview of the main aspects involved in the modeling of DC arc plasma torches: the mathematical models including thermodynamic and chemical non-equilibrium models, turbulent and radiative transport, thermodynamic and transport property calculation, boundary conditions and arc reattachment models. It focuses on the conventional plasma torches used for plasma spraying that include a hot-cathode and a nozzle anode.

  4. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer.

    Science.gov (United States)

    Martin, Jeffrey M; Handorf, Elizabeth A; Price, Robert A; Cherian, George; Buyyounouski, Mark K; Chen, David Y; Kutikov, Alexander; Johnson, Matthew E; Ma, Chung-Ming Charlie; Horwitz, Eric M

    2015-01-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

  5. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Jeffrey M. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Handorf, Elizabeth A. [Department of Biostatistics, Fox Chase Cancer Center, Philadelphia, PA (United States); Price, Robert A.; Cherian, George [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Buyyounouski, Mark K. [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Chen, David Y.; Kutikov, Alexander [Department of Urologic Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Johnson, Matthew E.; Ma, Chung-Ming Charlie [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Horwitz, Eric M., E-mail: eric.horwitz@fccc.edu [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-10-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

  6. A preliminary area survey of neutron radiation levels associated with the NASA variable energy cyclotron horizontal neutron delivery system

    Science.gov (United States)

    Roberts, W. K.; Leonard, R. F.

    1976-01-01

    The 25 MeV deuteron beam from the NASA variable energy cyclotron incident on a thick beryllium target will deliver a tissue neutron dose rate of 2.14 rad micron A-min at a source to skin distance of 125 cm. A neutron survey of the existing hallways with various shielding configurations made during operating of the horizontal neutron delivery system indicates that minimal amounts of additional neutron shielding material are required to provide a low level radiation environment within a self-contained neutron therapy control station. Measurements also indicate that the primary neutron distribution delivered by a planned vertical delivery system will be minimally perturbed by neutrons backscattered from the floor.

  7. Adaptive Liver Stereotactic Body Radiation Therapy: Automated Daily Plan Reoptimization Prevents Dose Delivery Degradation Caused by Anatomy Deformations

    Energy Technology Data Exchange (ETDEWEB)

    Leinders, Suzanne M. [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Delft University of Technology, Delft (Netherlands); Breedveld, Sebastiaan; Méndez Romero, Alejandra [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Schaart, Dennis [Delft University of Technology, Delft (Netherlands); Seppenwoolde, Yvette, E-mail: y.seppenwoolde@erasmusmc.nl [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands); Heijmen, Ben J.M. [Erasmus Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands)

    2013-12-01

    Purpose: To investigate how dose distributions for liver stereotactic body radiation therapy (SBRT) can be improved by using automated, daily plan reoptimization to account for anatomy deformations, compared with setup corrections only. Methods and Materials: For 12 tumors, 3 strategies for dose delivery were simulated. In the first strategy, computed tomography scans made before each treatment fraction were used only for patient repositioning before dose delivery for correction of detected tumor setup errors. In adaptive second and third strategies, in addition to the isocenter shift, intensity modulated radiation therapy beam profiles were reoptimized or both intensity profiles and beam orientations were reoptimized, respectively. All optimizations were performed with a recently published algorithm for automated, multicriteria optimization of both beam profiles and beam angles. Results: In 6 of 12 cases, violations of organs at risk (ie, heart, stomach, kidney) constraints of 1 to 6 Gy in single fractions occurred in cases of tumor repositioning only. By using the adaptive strategies, these could be avoided (<1 Gy). For 1 case, this needed adaptation by slightly underdosing the planning target volume. For 2 cases with restricted tumor dose in the planning phase to avoid organ-at-risk constraint violations, fraction doses could be increased by 1 and 2 Gy because of more favorable anatomy. Daily reoptimization of both beam profiles and beam angles (third strategy) performed slightly better than reoptimization of profiles only, but the latter required only a few minutes of computation time, whereas full reoptimization took several hours. Conclusions: This simulation study demonstrated that replanning based on daily acquired computed tomography scans can improve liver stereotactic body radiation therapy dose delivery.

  8. Volumetric intensity modulated arc therapy in lung cancer: Current literature review

    Directory of Open Access Journals (Sweden)

    Suresh B Rana

    2013-01-01

    Full Text Available The volumetric intensity modulated arc therapy (VMAT is a novel radiation technique that delivers a highly conformal radiation dose to the target by allowing the simultaneous variation of gantry rotation speed, dose rate and multiple-leaf collimators leaf positions. The aim of this study was to review the current literature on two VMAT systems, RapidArc and SmartArc with main focus on planning studies of lung cancer. A systematic review of available data was conducted using MEDLINE/PubMed with the keywords ′′lung′′ and "VMAT". The published data show that VMAT techniques have clear superiority over three-dimensional conformal radiation therapy with regard to improving dose conformity and sparing of organs at risks (OARs. The data indicates that for lung tumor VMAT and intensity modulated radiation therapy (IMRT provide equivalent dose homogeneity, dose conformity and target volume coverage; however, contradictory results were obtained in terms of OARs sparing. The major advantages of VMAT over IMRT are the reduction in the number of monitor units and faster treatment delivery times without compromising the quality of the treatment plans. Moreover, faster delivery time is more patient-friendly and it minimizes intra-fractional patient motion allowing treatment volumes stay within their respective treatment margins. Current literature data shows that VMAT can be a good option to treat lung cancer; however, data on clinical trials are still lacking. The clinical trials are essential to confirm the safety and efficacy of VMAT techniques.

  9. Arc Statistics

    CERN Document Server

    Meneghetti, M; Dahle, H; Limousin, M

    2013-01-01

    The existence of an arc statistics problem was at the center of a strong debate in the last fifteen years. With the aim to clarify if the optical depth for giant gravitational arcs by galaxy clusters in the so called concordance model is compatible with observations, several studies were carried out which helped to significantly improve our knowledge of strong lensing clusters, unveiling their extremely complex internal structure. In particular, the abundance and the frequency of strong lensing events like gravitational arcs turned out to be a potentially very powerful tool to trace the structure formation. However, given the limited size of observational and theoretical data-sets, the power of arc statistics as a cosmological tool has been only minimally exploited so far. On the other hand, the last years were characterized by significant advancements in the field, and several cluster surveys that are ongoing or planned for the near future seem to have the potential to make arc statistics a competitive cosmo...

  10. Impact of dose rate on accuracy of intensity modulated radiation therapy plan delivery using the pretreatment portal dosimetry quality assurance and setting up the workflow at hospital levels

    OpenAIRE

    Karunakaran Kaviarasu; N Arunai Nambi Raj; K Krishna Murthy; A Ananda Giri Babu; Bhaskar Laxman Durga Prasad

    2015-01-01

    The aim of this study was to examine the impact of dose rate on accuracy of intensity modulated radiation therapy (IMRT) plan delivery by comparing the gamma agreement between the calculated and measured portal doses by pretreatment quality assurance (QA) using electronic portal imaging device dosimetry and creating a workflow for the pretreatment IMRT QA at hospital levels. As the improvement in gamma agreement leads to increase in the quality of IMRT treatment delivery, gamma evaluation was...

  11. Effect of acoustic field parameters on arc acoustic binding during ultrasonic wave-assisted arc welding.

    Science.gov (United States)

    Xie, Weifeng; Fan, Chenglei; Yang, Chunli; Lin, Sanbao

    2016-03-01

    As a newly developed arc welding method, power ultrasound has been successfully introduced into arc and weld pool during ultrasonic wave-assisted arc welding process. The advanced process for molten metals can be realized by utilizing additional ultrasonic field. Under the action of the acoustic wave, the plasma arc as weld heat source is regulated and its characteristics make an obvious change. Compared with the conventional arc, the ultrasonic wave-assisted arc plasma is bound significantly and becomes brighter. To reveal the dependence of the acoustic binding force on acoustic field parameters, a two-dimensional acoustic field model for ultrasonic wave-assisted arc welding device is established. The influences of the radiator height, the central pore radius, the radiator radius, and curvature radius or depth of concave radiator surface are discussed using the boundary element method. Then the authors analyze the resonant mode by this relationship curve between acoustic radiation power and radiator height. Furthermore, the best acoustic binding ability is obtained by optimizing the geometric parameters of acoustic radiator. In addition, three concave radiator surfaces including spherical cap surface, paraboloid of revolution, and rotating single curved surface are investigated systematically. Finally, both the calculation and experiment suggest that, to obtain the best acoustic binding ability, the ultrasonic wave-assisted arc welding setup should be operated under the first resonant mode using a radiator with a spherical cap surface, a small central pore, a large section radius and an appropriate curvature radius.

  12. SU-E-T-568: Improving Normal Brain Sparing with Increasing Number of Arc Beams for Volume Modulated Arc Beam Radiosurgery of Multiple Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Hossain, S; Hildebrand, K; Ahmad, S [University of Oklahoma Health Science Center, Oklahoma City, OK (United States); Larson, D; Ma, L [University of California San Francisco, San Francisco, CA (United States); Sahgal, A [University of Toronto, Toronto, Ontario (Canada)

    2014-06-01

    Purpose: Intensity modulated arc beams have been newly reported for treating multiple brain metastases. The purpose of this study was to determine the variations in the normal brain doses with increasing number of arc beams for multiple brain metastases treatments via the TrueBeam Rapidarc system (Varian Oncology, Palo Alto, CA). Methods: A patient case with 12 metastatic brain lesions previously treated on the Leksell Gamma Knife Perfexion (GK) was used for the study. All lesions and organs at risk were contoured by a senior radiation oncologist and treatment plans for a subset of 3, 6, 9 and all 12 targets were developed for the TrueBeam Rapidarc system via 3 to 7 intensity modulated arc-beams with each target covered by at least 99% of the prescribed dose of 20 Gy. The peripheral normal brain isodose volumes as well as the total beam-on time were analyzed with increasing number of arc beams for these targets. Results: All intensisty modulated arc-beam plans produced efficient treatment delivery with the beam-on time averaging 0.6–1.5 min per lesion at an output of 1200 MU/min. With increasing number of arc beams, the peripheral normal brain isodose volumes such as the 12-Gy isodose line enclosed normal brain tissue volumes were on average decreased by 6%, 11%, 18%, and 28% for the 3-, 6-, 9-, 12-target treatment plans respectively. The lowest normal brain isodose volumes were consistently found for the 7-arc treatment plans for all the cases. Conclusion: With nearly identical beam-on times, the peripheral normal brain dose was notably decreased when the total number of intensity modulated arc beams was increased when treating multiple brain metastases. Dr Sahgal and Dr Ma are currently serving on the board of international society of stereotactic radiosurgery.

  13. A Treatment Planning and Acute Toxicity Comparison of Two Pelvic Nodal Volume Delineation Techniques and Delivery Comparison of Intensity-Modulated Radiotherapy Versus Volumetric Modulated Arc Therapy for Hypofractionated High-Risk Prostate Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Myrehaug, Sten [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada); Chan, Gordon [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Craig, Tim [Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada); Weinberg, Vivian [Biostatistics Core, Helen Diller Family Comprehensive Cancer Center, University of California San Francisco, San Francisco, CA (United States); Cheng, Chun [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Roach, Mack [Department of Radiation Oncology, University of California San Francisco, San Francisco, CA (United States); Cheung, Patrick [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Sahgal, Arjun, E-mail: arjun.sahgal@sunnybrook.ca [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada)

    2012-03-15

    Purpose: To perform a comparison of two pelvic lymph node volume delineation strategies used in intensity-modulated radiotherapy (IMRT) for high risk prostate cancer and to determine the role of volumetric modulated arc therapy (VMAT). Methods and Materials: Eighteen consecutive patients accrued to an ongoing clinical trial were identified according to either the nodal contouring strategy as described based on lymphotropic nanoparticle-enhanced magnetic resonance imaging technology (9 patients) or the current Radiation Therapy Oncology Group (RTOG) consensus guidelines (9 patients). Radiation consisted of 45 Gy to prostate, seminal vesicles, and lymph nodes, with a simultaneous integrated boost to the prostate alone, to a total dose of 67.5 Gy delivered in 25 fractions. Prospective acute genitourinary and gastrointestinal toxicities were compared at baseline, during radiotherapy, and 3 months after radiotherapy. Each patient was retrospectively replanned using the opposite method of nodal contouring, and plans were normalized for dosimetric comparison. VMAT plans were also generated according to the RTOG method for comparison. Results: RTOG plans resulted in a significantly lower rate of genitourinary frequency 3 months after treatment. The dosimetric comparison showed that the RTOG plans resulted in both favorable planning target volume (PTV) coverage and lower organs at risk (OARs) and integral (ID) doses. VMAT required two to three arcs to achieve adequate treatment plans, we did not observe consistent dosimetric benefits to either the PTV or the OARs, and a higher ID was observed. However, treatment times were significantly shorter with VMAT. Conclusion: The RTOG guidelines for pelvic nodal volume delineation results in favorable dosimetry and acceptable acute toxicities for both the target and OARs. We are unable to conclude that VMAT provides a benefit compared with IMRT.

  14. Fabrication and in vitro characterization of gadolinium-based nanoclusters for simultaneous drug delivery and radiation enhancement

    Science.gov (United States)

    Yoo, Shannon S.; Guo, Linghong; Sun, Xuejun; Shaw, Andrew R.; Yuan, Zhipeng; Löbenberg, Raimar; Roa, Wilson H.

    2016-09-01

    We report the synthesis of a gadolinium hydroxide (Gd(OH)3) nanorod based doxorubicin (Dox) delivery system that can enhance both magnetic resonance imaging contrast and radiation sensitivity. A simple and cost effective wet-chemical method was utilized in the presence of manganese (Mn) ions and Dox to produce the Gd(OH)3:Mn·Dox nanocluster structure. The Gd(OH)3:Mn·Dox nanocluster was composed of Mn-doped Gd(OH)3 nanorods arranged in parallel with Dox as a linker molecule between the adjacent nanorods. No other studies have utilized Dox as both the linker and therapeutic molecule in a nanostructure to date. The Gd(OH)3 nanorod is reported to have no significant cellular or in vivo toxicity, which makes it an ideal base material for this biomedical application. The Gd(OH)3:Mn·Dox nanocluster exhibited paramagnetic behavior and was stable in a colloidal solution. The nanocluster also enabled high Dox loading capacity and specifically released Dox in a sustained and pH-dependent manner. The positively charged Gd(OH)3:Mn·Dox nanoclusters were readily internalized into MDA-MB-231 breast cancer cells via endocytosis, which resulted in intracellular release of Dox. The released Dox in cells was effective in conferring cytotoxicity and inhibiting proliferation of cancer cells. Furthermore, a synergistic anticancer effect could be observed with radiation treatment. Overall, the Gd(OH)3:Mn·Dox nanocluster drug delivery system described herein may have potential utility in clinics as a multifunctional theranostic nanoparticle with combined benefits in both diagnosis and therapy in the management of cancer.

  15. A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Mi Sook; Yoon, In Ha; Hong, Dong Gi; Back, Geum Mun [Dept. of Radiation Oncology, ASAN Medical Center, Seoul (Korea, Republic of)

    2015-06-15

    Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. The treatment plans for five patients, being treated on TrueBeam STx(Varian™, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Average value of CI, HI and PCI for PTV was 1.381±0.028, 1.096±0.016, 0.944±0.473 in VMAT and 1.381± 0.042, 1.136±0.042, 1.534±0.465 in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  16. Quality keeping and upgrading technique on delivery of raw fodder and so forth by using radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Ryoei; Tanaka, Osamu; Uegaki, Ryuichi; Ando, Sada; Akiyama, Fumiaki; Yamada, Akio [National Grassland Research Inst., Nishinasuno, Tochigi (Japan)

    1998-02-01

    As most of aerobic bacteria, anaerobic spore bacteria, molds and yeasts died owing to 8 to 16 kGy of {gamma}-ray irradiation, it was found that butyric acid fermentation and aerobic putrefaction in silage did not form. As the lactobacilli bringing good fermentation quality died as well at such radiation dose, on a case of a mixed silage using the dregs, in which lactic acid was present, quality of its fermentation was good. And, many informations on changes in fatty quality and yeast activity in the silage formed by irradiation could also be obtained. As the dregs had a large difference in physical and chemical components, quality after preparation of the silage was not uniform. Materials suitable for {gamma}-ray irradiation and radiation dose suitable for each material was found to be clarified. (G.K.)

  17. Design of a Solar Greenhouse with Energy Delivery by the Conversion of Near Infrared Radiation - Part 1 Optics and PV-cells

    NARCIS (Netherlands)

    Sonneveld, Piet; Swinkels, Gert-Jan; Bot, G.P.A.

    2009-01-01

    In this paper the design and development of a new type of greenhouse with an integrated filter for reflecting near infrared radiation (NIR) and a solar energy delivery system is described. Especially the optical parts as the spectral selective film, the properties of the circular reflector and the e

  18. Measurement of an Electric Arc Spectra

    OpenAIRE

    Šimek, D.

    2015-01-01

    Article is focused on electric arc spectroscopy diagnostics related to electric low voltage apparatuses. The first attempts of spectroscopy measurements are dealt with. An example of radiation spectra of the electric arc burning between copper electrodes is presented. The problems connected with the measurements are discussed.

  19. TAT-Mediated Delivery of Tousled Protein to Salivary Glands Protects Against Radiation-Induced Hypofunction

    Energy Technology Data Exchange (ETDEWEB)

    Sunavala-Dossabhoy, Gulshan, E-mail: gsunav@lsuhsc.edu [Department of Biochemistry and Molecular Biology, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Palaniyandi, Senthilnathan; Richardson, Charles; De Benedetti, Arrigo [Department of Biochemistry and Molecular Biology, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Schrott, Lisa [Department of Pharmacology, Toxicology, and Neuroscience, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Caldito, Gloria [Department of Bioinformatics and Computational Biology, Louisiana State University Health Sciences Center, Shreveport, LA (United States)

    2012-09-01

    Purpose: Patients treated with radiotherapy for head-and-neck cancer invariably suffer its deleterious side effect, xerostomia. Salivary hypofunction ensuing from the irreversible destruction of glands is the most common and debilitating oral complication affecting patients undergoing regional radiotherapy. Given that the current management of xerostomia is palliative and ineffective, efforts are now directed toward preventive measures to preserve gland function. The human homolog of Tousled protein, TLK1B, facilitates chromatin remodeling at DNA repair sites and improves cell survival against ionizing radiation (IR). Therefore, we wanted to determine whether a direct transfer of TLK1B protein to rat salivary glands could protect against IR-induced salivary hypofunction. Methods: The cell-permeable TAT-TLK1B fusion protein was generated. Rat acinar cell line and rat salivary glands were pretreated with TAT peptide or TAT-TLK1B before IR. The acinar cell survival in vitro and salivary function in vivo were assessed after radiation. Results: We demonstrated that rat acinar cells transduced with TAT-TLK1B were more resistant to radiation (D{sub 0} = 4.13 {+-} 1.0 Gy; {alpha}/{beta} = 0 Gy) compared with cells transduced with the TAT peptide (D{sub 0} = 4.91 {+-} 1.0 Gy; {alpha}/{beta} = 20.2 Gy). Correspondingly, retroductal instillation of TAT-TLK1B in rat submandibular glands better preserved salivary flow after IR (89%) compared with animals pretreated with Opti-MEM or TAT peptide (31% and 39%, respectively; p < 0.01). Conclusions: The results demonstrate that a direct transfer of TLK1B protein to the salivary glands effectively attenuates radiation-mediated gland dysfunction. Prophylactic TLK1B-protein therapy could benefit patients undergoing radiotherapy for head-and-neck cancer.

  20. Development of novel hydrogels by modification of sterculia gum through radiation cross-linking polymerization for use in drug delivery

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Baljit [Department of Chemistry, Himachal Pradesh University, Shimla - 171005 (India)], E-mail: baljitsinghhpu@yahoo.com; Vashishtha, Manu [Department of Chemistry, Himachal Pradesh University, Shimla - 171005 (India)

    2008-05-15

    In order to modify the sterculia gum polysaccharide, to develop the hydrogels meant for the drug delivery, we have prepared sterculia gum, 2-hydroxyethylmethacrylate (HEMA) and acrylic acid (AAc) based hydrogels by radiation-induced crosslinking polymerization. Polymeric networks (hydrogels) thus formed were characterized with SEMs, FTIR,TGA and swelling studies which were carried out as a function monomers concentration, radiation dose, amount of sterculia contents in the polymer matrix and nature of the swelling medium. This paper discusses the swelling kinetics of the hydrogels and release dynamics of anti-diarrhea model drug ornidazole from the hydrogels to evaluation of swelling and drug release mechanism. Diffusion exponent 'n' have 0.73, 0.56 and 0.61 values and gel characteristic constant 'k' have 1.28 x 10{sup -2}, 2.95 x 10{sup -2} and 2.14 x 10{sup -2} values in distilled water, pH 2.2 buffer and pH 7.4 buffer. The release of drug from the polymer matrix occurred through non-Fickian diffusion mechanism. The values for the late time diffusion coefficients have been lower than the values of initial and average diffusion coefficients. It reflects that in the initial stages rate of release of drug from polymer matrix was higher as compared to the late stages, it means after certain time the drug release occurred in controlled manner.

  1. Hollow polycarbonate waveguides with inner Cu coatings for delivery of terahertz radiation.

    Science.gov (United States)

    Harrington, James; George, Roshan; Pedersen, Pal; Mueller, Eric

    2004-10-18

    Terahertz (THz) radiation has important applications in spectroscopy, imaging, and space science. Fiber optics for the THz region have been limited to rigid hollow metallic waveguides or short lengths of solid-core transparent dielectrics such as sapphire and plastic. We have fabricated flexible, hollow polycarbonate waveguides with interior Cu coatings for broadband THz transmission using simple liquid-phase chemistry techniques. The losses for these hollow-core guides were measured using a tunable, cw single-mode far IR laser. The losses for the best guides were found to be less than four dB/m and the single mode of the laser was preserved for the smaller bore waveguides.

  2. Potential for reduced radiation-induced toxicity using intensity-modulated arc therapy for whole-brain radiotherapy with hippocampal sparing.

    Science.gov (United States)

    Pokhrel, Damodar; Sood, Sumit; Lominska, Christopher; Kumar, Pravesh; Badkul, Rajeev; Jiang, Hongyu; Wang, Fen

    2015-09-08

    The purpose of this study was to retrospectively investigate the accuracy, plan quality, and efficiency of using intensity-modulated arc therapy (IMAT) for whole brain radiotherapy (WBRT) patients with sparing not only the hippocampus (following RTOG 0933 compliance criteria) but also other organs at risk (OARs). A total of 10 patients previously treated with nonconformal opposed laterals whole-brain radiotherapy (NC-WBRT) were retrospectively replanned for hippocampal sparing using IMAT treatment planning. The hippocampus was volumetrically contoured on fused diagnostic T1-weighted MRI with planning CT images and hippocampus avoidance zone (HAZ) was generated using a 5 mm uniform margin around the hippocampus. Both hippocampi were defined as one paired organ. Whole brain tissue minus HAZ was defined as the whole-brain planning target volume (WB-PTV). Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5 mm leaf width at isocenter) and 6 MV beam for a prescription dose of 30 Gy in 10 fractions following RTOG 0933 dosimetric criteria. Two full coplanar arcs with orbits avoidance sectors were used. In addition to RTOG criteria, doses to other organs at risk (OARs), such as parotid glands, cochlea, external/middle ear canals, skin, scalp, optic pathways, brainstem, and eyes/lens, were also evaluated. Subsequently, dose delivery efficiency and accuracy of each IMAT plan was assessed by delivering quality assurance (QA) plans with a MapCHECK device, recording actual beam-on time and measuring planed vs. measured dose agreement using a gamma index. On IMAT plans, following RTOG 0933 dosimetric criteria, the maximum dose to WB-PTV, mean WB-PTV D2%, and mean WB-PTV D98% were 34.9 ± 0.3 Gy, 33.2 ± 0.4 Gy, and 26.0± 0.4Gy, respectively. Accordingly, WB-PTV received the prescription dose of 30Gy and mean V30 was 90.5% ± 0.5%. The D100%, and

  3. Electrode Evaporation Effects on Air Arc Behavior

    Institute of Scientific and Technical Information of China (English)

    LI Xingwen; CHEN Degui; LI Rui; WU Yi; NIU Chunping

    2008-01-01

    A numerical study of the effects of copper and silver vapours on the air arc behavior is performed. The commercial software FLUENT is adapted and modified to develop a two-dimensional magneto-hydrodynamic (MHD) models of arc with the thermodynamic properties and transport coefficients, net emission coefficient for the radiation model of 99% ai-1% Cu, 99% air-1% Ag, and pure air, respectively. The simulation result demonstrates that vaporization of the electrode material may cool the arc center region and reduce the arc velocity. The effects of Ag vapour are stronger compared to those of Cu vapour.

  4. Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC) leaves for volumetric modulated arc therapy (VMAT)

    OpenAIRE

    2016-01-01

    Background This study is to report 1) the sensitivity of intensity modulated radiation therapy (IMRT) QA method for clinical volumetric modulated arc therapy (VMAT) plans with multi-leaf collimator (MLC) leaf errors that will not trigger MLC interlock during beam delivery; 2) the effect of non-beam-hold MLC leaf errors on the quality of VMAT plan dose delivery. Materials and methods. Eleven VMAT plans were selected and modified using an in-house developed software. For each control point of a...

  5. Radiation-grafting of acrylamide onto silicone rubber films for diclofenac delivery

    Science.gov (United States)

    Magaña, Hector; Palomino, Kenia; Cornejo-Bravo, Jose M.; Alvarez-Lorenzo, Carmen; Concheiro, Angel; Bucio, Emilio

    2015-02-01

    This work focuses on the pre-irradiation grafting of acrylamide (AAm) onto silicone rubber films (SR) and evaluates the effect of gamma-ray radiation conditions on the grafting yield, which in turn may influence the performance of the grafted materials as components of drug-eluting devices. Pristine and modified SR were characterized using FTIR-ATR, DSC, TGA, swelling, and water contact angle analysis in order to elucidate the effects of AAm grafting onto SR. Grafted films with content in AAm ranging from 0.81% to 22.20% showed excellent cytocompatibility against fibroblasts, and capability to uptake the anti-inflammatory drug diclofenac. Amount of drug loaded directly correlated with the grafting degree of the films. Drug release studies were performed at pH 7.4 and 37 °C (physiological conditions). Most grafted films released the drug in a sustained way for at least three hours.

  6. Rapid Arc, helical tomotherapy, sliding window intensity modulated radiotherapy and three dimensional conformal radiation for localized prostate cancer: A dosimetric comparison

    Directory of Open Access Journals (Sweden)

    Rajesh A Kinhikar

    2014-01-01

    Full Text Available Objective: The objective of this study was to investigate the potential role of RapidArc (RA compared with helical tomotherapy (HT, sliding window intensity modulated radiotherapy (SW IMRT and three-dimensional conformal radiation therapy (3D CRT for localized prostate cancer. Materials and Methods: Prescription doses ranged from 60 Gy to planning target volume (PTV and 66.25 Gy for clinical target volume prostate (CTV-P over 25-30 fractions. PTV and CTV-P coverage were evaluated by conformity index (CI and homogeneity index (HI. Organ sparing comparison was done with mean doses to rectum and bladder. Results: CI 95 were 1.0 ± 0.01 (RA, 0.99 ± 0.01 (HT, 0.97 ± 0.02 (IMRT, 0.98 ± 0.02 (3D CRT for PTV and 1.0 ± 0.00 (RA, HT, SW IMRT and 3D CRT for CTV-P. HI was 0.11 ± 0.03 (RA, 0.16 ± 0.08 (HT, 0.12 ± 0.03 (IMRT, 0.06 ± 0.01 (3D CRT for PTV and 0.03 ± 0.00 (RA, 0.05 ± 0.01 (HT, 0.03 ± 0.01 (SW IMRT and 3D CRT for CTV-P. Mean dose to bladder were 23.68 ± 13.23 Gy (RA, 24.55 ± 12.51 Gy (HT, 19.82 ± 11.61 Gy (IMRT and 23.56 ± 12.81 Gy (3D CRT, whereas mean dose to rectum was 36.85 ± 12.92 Gy (RA, 33.18 ± 11.12 Gy (HT, IMRT and 38.67 ± 12.84 Gy (3D CRT. Conclusion: All studied intensity-modulated techniques yield treatment plans of significantly improved quality when compared with 3D CRT, with HT providing best organs at risk sparing and RA being the most efficient treatment option, reducing treatment time to 1.45-3.7 min and monitor unit to <400 for a 2 Gy fraction.

  7. SU-E-T-618: Plan Robustness Study of Volumetric-Modulated Arc Therapy Vs. Intensity-Modulated Radiation Therapy for Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, W; Patel, S; Shen, J; Harrington, D; Stoker, J; Ding, X; Hu, Y; Wong, W; Halyard, M; Schild, S; Ezzell, G; Bues, M [Mayo Clinic Arizona, Phoenix, AZ (United States)

    2015-06-15

    Purpose: Lack of plan robustness may contribute to local failure in volumetric-modulated arc therapy (VMAT) to treat head and neck (H&N) cancer. Thus we compared plan robustness of VMAT with intensity-modulated radiation therapy (IMRT). Methods: VMAT and IMRT plans were created for 9 H&N cancer patients. For each plan, six new perturbed dose distributions were computed — one each for ± 3mm setup deviations along the S-I, A-P and L-R directions. We used three robustness quantification tools: (1) worst-case analysis (WCA); (2) dose-volume histograms (DVHs) band (DVHB); and (3) root-mean-square-dose deviation (RMSD) volume histogram (DDVH). DDVH represents the relative volume (y) on the vertical axis and the RMSD (x) on the horizontal axis. Similar to DVH, this means that y% of the volume of the indicated structure has the RMSD at least x Gy[RBE].The width from the first two methods at different target DVH indices (such as D95 and D5) and the area under the DDVH curves (AUC) for the target were used to indicate plan robustness. In these robustness quantification tools, the smaller the value, the more robust the plan is. Plan robustness evaluation metrics were compared using Wilcoxon test. Results: DVHB showed the width at D95 from IMRT to be larger than from VMAT (unit Gy) [1.59 vs 1.18 (p=0.49)], while the width at D5 from IMRT was found to be slightly larger than from VMAT [0.59 vs 0.54 (p=0.84)]. WCA showed similar results [D95: 3.28 vs 3.00 (p=0.56); D5: 1.68 vs 1.95 (p=0.23)]. DDVH showed the AUC from IMRT to be slightly smaller than from VMAT [1.13 vs 1.15 (p=0.43)]. Conclusion: VMAT plan robustness is comparable to IMRT plan robustness. The plan robustness conclusions from WCA and DVHB are DVH parameter dependent. On the other hand DDVH captures the overall effect of uncertainties on the dose to a volume of interest. NIH/NCI K25CA168984; Eagles Cancer Research Career Development; The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research Mayo ASU Seed

  8. Leakage-Penumbra effect in intensity modulated radiation therapy step-and-shoot dose delivery

    Institute of Scientific and Technical Information of China (English)

    Grigor N Grigorov; James CL Chow

    2016-01-01

    AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected prostate IMRT plans were studied. The IMRT plans were delivered by a Varian 21 EX linear accelerator equipped with a 120-leaf multileaf collimator(MLC). For each treatment plan created by the Pinnacle3 treatment planning system,a 3-dimensional LP dose distribution generated by 5 coplanar photon beams,starting from 0o with equal separation of 72 o,was investigated. For each photon beam used in the stepand-shoot IMRT plans,the first beam segment was set to have the largest area in the MLC leaf-sequencing,and was equal to the planning target volume(PTV). The overshoot effect(OSE) and the segment positional errors were measured using a solid water phantom with Kodak(TL and X-OMAT V) radiographic films. Film dosimetric analysis and calibration were carried out using a film scanner(Vidar VXR-16). The LP dose profiles were determined by eliminating the OSE and segment positional errors with specific individual irradiations. RESULTS: A non-uniformly distributed leaf LP dose ranging from 3% to 5% of the beam dose was measured in clinical IMRT beams. An overdose at the gap between neighboring segments,represented as dose peaks of up to 10% of the total BP,was measured. The LP effect increased the dose to the PTV and surrounding critical tissues. In addition,the effectdepends on the number of beams and segments for each beam. Segment positional error was less than the maximum tolerance of 1 mm under a dose rate of 600 monitor units per minute in the treatment plans. The OSE varying with the dose rate was observed in all photon beams,and the effect increased from 1 to 1.3 Gy per treatment of the rectal intersection. As the dosimetric impacts from the LP effect and OSE may increase the rectal post-radiation effects,a correction of LP was proposed and demonstrated for

  9. A fully electronic intensity-modulated radiation therapy quality assurance (IMRT QA) process implemented in a network comprised of independent treatment planning, record and verify, and delivery systems:

    OpenAIRE

    2010-01-01

    Background The purpose of this study is to implement an electronic method to perform and analyze intensity-modulated radiation therapy quality assurance (IMRT QA) using an aSi megavoltage electronic portal imaging device in a network comprised of independent treatment planning, record and verify (R&V), and delivery systems. Methods A verification plan was generated in the treatment planning system using the actual treatment plan of a patient. After exporting the treatment fields to the R&V sy...

  10. SU-E-T-810: Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Non-Small-Cell Lung Cancer with Simultaneously Integrated Boost Radiation Therapy: A Planning Comparison Study

    Energy Technology Data Exchange (ETDEWEB)

    Liu, T; Chen, J; Zhang, G; Sun, T [Shandong Tumor Hospital, Jinan, Shandong (China)

    2015-06-15

    Purpose: To compare and analyze the characteristics of intensity-modulated arc therapy(IMAT) versus fixed-gantry intensity-modulated radiotherapy(IMRT) in treatment of non-small-cell lung cancer. Methods: Twelve patients treated in our radiotherapy center were selected for this study. The patient subsequently underwent 4D-CT simulation.Margins of 5mm and 10mm were added to the ITV to generate the CTV and PTV respectively. Three treatment plans (IMRT,one single arc (RA1),double arcs (RA2))were generated with Eclipse ver.8.6 planning systems. Using a dose level of 75Gy in 15fractions to the ITV,60Gy in 15fractions to the CTV and 45Gy in 15fractions to the PTV respectively. The target and normol tissue volumes were compared,as were the dosimetry parameters. Results: There were no significant differences in CI of ITV,PTV,HI of ITV,CTV and PTV, V5,V10,V15,V20,V25,V30,V45,V50 of total-lung and mean lung dose (all p>0.05). However, the differences were significant in terms of CI of CTV,V5 of B-P (all p<0.05). On the MU, IMRT=1540MU,RA1=1006 MU and RA2=1096 MU. (F=12.00,P=0.000).On the treatment time, IMRT= 13.5min,RA1= 1.5min,and RA2=2.5 min (F= 30.11,P=0.000 ). Conclusion: IMAT is equal to IMRT in dosimetril evaluation. Due to much less Mu and delivery time,IMAT is an ideal technique in treating patients by reduceing the uncomfortable influnce which could effect the treatment.

  11. Simulation of the Effects of Several Factors on Arc Plasma Behavior in Low Voltage Circuit Breaker

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Taking into account the properties of the arc plasma and the electromagnetic, heat and radiative phenomena, commercial computational fluid dynamics software PHOENICS has been adapted and modified to develop the three-dimensional magneto-hydrodynamic (MHD)model of arc in a low voltage circuit breaker. The effects of the arc ignition location, venting size and gassing material on arc behavior have been investigated. The analysis of the results show that the arc velocity accelerates with the increase in the distance between arc ignition location and of the venting size, and the existence of the gassing material is beneficial to improving the arc voltage and reducing the arc temperature.

  12. Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: retrospective physician surveys including chart reviews at numerous centers.

    Science.gov (United States)

    Gossman, Michael S; Wilkinson, Jeffrey D; Mallick, Avishek

    2014-01-01

    In a 2-part study, we first examined the results of 71 surveyed physicians who provided responses on how they address the management of patients who maintained either a pacemaker or a defibrillator during radiation treatment. Second, a case review study is presented involving 112 medical records reviewed at 18 institutions to determine whether there was a change in the radiation prescription for the treatment of the target cancer, the method of radiation delivery, or the method of radiation image acquisition. Statistics are provided to illustrate the level of administrative policy; the level of communication between radiation oncologists and heart specialists; American Joint Committee on Cancer (AJCC) staging and classification; National Comprehensive Cancer Network (NCCN) guidelines; tumor site; patient׳s sex; patient׳s age; device type; manufacturer; live monitoring; and the reported decisions for planning, delivery, and imaging. This survey revealed that 37% of patient treatments were considered for some sort of change in this regard, whereas 59% of patients were treated without regard to these alternatives when available. Only 3% of all patients were identified with an observable change in the functionality of the device or patient status in comparison with 96% of patients with normal behavior and operating devices. Documented changes in the patient׳s medical record included 1 device exhibiting failure at 0.3-Gy dose, 1 device exhibiting increased sensor rate during dose delivery, 1 patient having an irregular heartbeat leading to device reprogramming, and 1 patient complained of twinging in the chest wall that resulted in a respiratory arrest. Although policies and procedures should directly involve the qualified medical physicist for technical supervision, their sufficient involvement was typically not requested by most respondents. No treatment options were denied to any patient based on AJCC staging, classification, or NCCN practice standards.

  13. Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: Retrospective physician surveys including chart reviews at numerous centers

    Energy Technology Data Exchange (ETDEWEB)

    Gossman, Michael S., E-mail: MGossman@TSRCC.com [Regulation Directive Medical Physics, Russell, KY (United States); Wilkinson, Jeffrey D. [Medtronic, Inc., Mounds View, MN (United States); Mallick, Avishek [Department of Mathematics, Marshall University, Huntington, WV (United States)

    2014-01-01

    In a 2-part study, we first examined the results of 71 surveyed physicians who provided responses on how they address the management of patients who maintained either a pacemaker or a defibrillator during radiation treatment. Second, a case review study is presented involving 112 medical records reviewed at 18 institutions to determine whether there was a change in the radiation prescription for the treatment of the target cancer, the method of radiation delivery, or the method of radiation image acquisition. Statistics are provided to illustrate the level of administrative policy; the level of communication between radiation oncologists and heart specialists; American Joint Committee on Cancer (AJCC) staging and classification; National Comprehensive Cancer Network (NCCN) guidelines; tumor site; patient's sex; patient's age; device type; manufacturer; live monitoring; and the reported decisions for planning, delivery, and imaging. This survey revealed that 37% of patient treatments were considered for some sort of change in this regard, whereas 59% of patients were treated without regard to these alternatives when available. Only 3% of all patients were identified with an observable change in the functionality of the device or patient status in comparison with 96% of patients with normal behavior and operating devices. Documented changes in the patient's medical record included 1 device exhibiting failure at 0.3-Gy dose, 1 device exhibiting increased sensor rate during dose delivery, 1 patient having an irregular heartbeat leading to device reprogramming, and 1 patient complained of twinging in the chest wall that resulted in a respiratory arrest. Although policies and procedures should directly involve the qualified medical physicist for technical supervision, their sufficient involvement was typically not requested by most respondents. No treatment options were denied to any patient based on AJCC staging, classification, or NCCN practice standards.

  14. Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT.

    Science.gov (United States)

    McCurdy, B M C; Greer, P B

    2009-07-01

    Dosimetric properties of an amorphous-silicon electronic portal imaging device (EPID) operated in a real-time acquisition mode were investigated. This mode will be essential for time-resolved dose verification of dynamic (sliding window) intensity modulated radiation therapy (IMRT) and intensity modulated arc radiation therapy (arc-IMRT). The EPID was used in continuous acquisition mode (i.e., "cine" mode) where individual sequential image frames are acquired in real time. The properties studied include dose linearity, reproducibility of response, and image stability. Results of using the continuous acquisition mode with several example treatments including dynamic IMRT, arc treatment, and single-arc-IMRT are compared to results using the well-studied integrated acquisition mode (i.e., "frame averaging" or "IMRT" mode). Real-time EPID response was also compared to real-time ion-chamber data for selected points in the deliveries. The example treatment deliveries in both continuous and integrated acquisition modes were converted to arbitrary EPID dose units via a calibration field. The summation of all acquired continuous mode images was compared using percentage dose difference to the single image acquired in the integrated mode using in-field pixels only (defined as those pixels > 10% of maximum, in-field signal). Using the continuous acquisition mode, the EPID response was not linear with dose. It was found that the continuous mode dose response corresponded approximately to dropping one image per acquisition session. Reproducibility of EPID response to low monitor units (MUs) was found to be poor but greatly improved with increasing MU. Open field profiles were found to be stable in the cross-plane direction but required several frames to become stable in the in-plane direction. However, both of these issues are clinically insignificant due to arc-IMRT deliveries requiring relatively large monitor units (> 100 MU). Analysis of the five IMRT, arc, and arc

  15. Non-coplanar volumetric-modulated arc therapy (VMAT) for craniopharyngiomas reduces radiation doses to the bilateral hippocampus: A planning study comparing dynamic conformal arc therapy, coplanar VMAT, and non-coplanar VMAT

    OpenAIRE

    Uto, Megumi; Mizowaki, Takashi; OGURA, KENGO; Hiraoka, Masahiro

    2016-01-01

    Background Recent studies suggest that radiation-induced injuries to the hippocampus play important roles in compromising neurocognitive functioning for patients with brain tumors and it could be important to spare the hippocampus using modern planning methods for patients with craniopharyngiomas. As bilateral hippocampus are located on the same level as the planning target volume (PTV) in patients with craniopharyngioma, it seems possible to reduce doses to hippocampus using non-coplanar bea...

  16. Gas arc constriction for plasma arc welding

    Science.gov (United States)

    McGee, William F. (Inventor); Rybicki, Daniel J. (Inventor)

    1994-01-01

    A welding torch for plasma arc welding apparatus has an inert gas applied circumferentially about the arc column externally of the constricting nozzle so as to apply a constricting force on the arc after it has exited the nozzle orifice and downstream of the auxiliary shielding gas. The constricting inert gas is supplied to a plenum chamber about the body of the torch and exits through a series of circumferentially disposed orifices in an annular wall forming a closure at the forward end of the constricting gas plenum chamber. The constricting force of the circumferential gas flow about the arc concentrates and focuses the arc column into a more narrow and dense column of energy after exiting the nozzle orifice so that the arc better retains its energy density prior to contacting the workpiece.

  17. Industry-relevant magnetron sputtering and cathodic arc ultra-high vacuum deposition system for in situ x-ray diffraction studies of thin film growth using high energy synchrotron radiation.

    Science.gov (United States)

    Schroeder, J L; Thomson, W; Howard, B; Schell, N; Näslund, L-Å; Rogström, L; Johansson-Jõesaar, M P; Ghafoor, N; Odén, M; Nothnagel, E; Shepard, A; Greer, J; Birch, J

    2015-09-01

    We present an industry-relevant, large-scale, ultra-high vacuum (UHV) magnetron sputtering and cathodic arc deposition system purposefully designed for time-resolved in situ thin film deposition/annealing studies using high-energy (>50 keV), high photon flux (>10(12) ph/s) synchrotron radiation. The high photon flux, combined with a fast-acquisition-time (<1 s) two-dimensional (2D) detector, permits time-resolved in situ structural analysis of thin film formation processes. The high-energy synchrotron-radiation based x-rays result in small scattering angles (<11°), allowing large areas of reciprocal space to be imaged with a 2D detector. The system has been designed for use on the 1-tonne, ultra-high load, high-resolution hexapod at the P07 High Energy Materials Science beamline at PETRA III at the Deutsches Elektronen-Synchrotron in Hamburg, Germany. The deposition system includes standard features of a typical UHV deposition system plus a range of special features suited for synchrotron radiation studies and industry-relevant processes. We openly encourage the materials research community to contact us for collaborative opportunities using this unique and versatile scientific instrument.

  18. Sky Radiometers on Stand for Downwelling Radiation

    Data.gov (United States)

    Oak Ridge National Laboratory — The Sky Radiation (SKYRAD) collection of radiometers provides each Atmospheric Radiation and Cloud Station (ARCS) with continuous measurements of broadband shortwave...

  19. SU-E-T-62: A Preliminary Experience of Using EPID Transit Dosimetry for Monitoring Daily Dose Variations in Radiation Treatment Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Yao, R; Chisela, W [Columbus Regional Healthcare, Columbus, GA (United States)

    2015-06-15

    Purpose: To investigate the use of EPID transit dosimetry for monitoring daily dose variations in radiation treatment delivery. Methods: A patient with head and neck cancer treated using nine field IMRT beams was used in this study. The prescription was 45 Gy in 25 fractions. A KV CBCT was acquired before each treatment on a Varian NTX linear accelerator. Integrated images using MV EPID were acquired for each treatment beam. Planning CT images, treatment plan, and daily integrated images were imported into a commercial QA software Dosimetry Check (v4r4 Math Resolutions, LLC, Columbia, MD) to calculate 3D dose of the day assuming 25 fractions treatment. Planning CT images were deformed and registered to each daily CBCT using Varian SmartAdapt (v11.MR2). ROIs were then propagated from planning CT to daily CBCT. The correlation between maximum, average dose of ROIs and ROI volume, center of mass shift, Dice Similarity Coefficient (DSC) were investigated. Results: Not all parameters investigated showed strong correlations. For PTV and CTV, the average dose has inverse correlation with their volume change (correlation coefficient −0.52, −0.50, respectively) and DSC (−0.59, −0.59, respectively). The average dose of right parotid has correlation with its volume change (0.56). The maximum dose of spinal cord has correlation with the center of mass superior-inferior shift (0.52) and inverse correlation with the center of mass anterior-posterior shift (−0.73). Conclusion: Transit dosimetry using EPID images collected during treatment delivery offers great potential to monitor daily dose variations due to patient anatomy change, motion, and setup errors in radiation treatment delivery. It can provide a patient-specific QA tool valuable for adaptive radiation therapy. Further work is needed to validate the technique.

  20. Water-vortex-stabilized electric arc: III. Radial energy transport, determination of water-vapour-boundary and arc performance

    Science.gov (United States)

    Jenista, Jirí

    2003-12-01

    This paper is concerned with numerical modelling of an electric arc stabilized by a water vortex. The two-dimensional axisymmetric model presented includes the arc discharge area between the cathode and the outlet nozzle of the water plasma torch. The aims of the numerical simulations are: (1) to assess the influence of radial position of the water-vapour-boundary in the discharge chamber on arc performance and overall radial energy transport within the arc; (2) to determine the most probable mass flow rates and radii of the water-vapour-boundary in the discharge chamber for a prescribed current; (3) to demonstrate arc performance for two radiation models involved; and (4) to estimate validity of local thermodynamic equilibrium (LTE) conditions within the arc column. The rate of evaporation of water is calculated from the conduction and radiation heat fluxes at the water vapour surface for the specified mass flow rate. The behaviour of such an arc has been studied for a range of current 300-600 A. It is shown that changes of bulk magnitudes of different terms in the momentum and energy equations within the arc column as a function of arc radius enable us to reveal transitions of temperature and velocity fields from one steady state to a qualitatively different one. The best fit between experiment and numerical simulation for all currents exists for the mean arc radius ~3.3 mm. Deviations from LTE within the arc column are estimated with the criteria for kinetic equilibrium and spatial temperature gradients.

  1. Process characteristics of fibre-laser-assisted plasma arc welding

    Energy Technology Data Exchange (ETDEWEB)

    Mahrle, A; Schnick, M; Rose, S; Demuth, C; Beyer, E; Fuessel, U, E-mail: achim.mahrle@iws.fraunhofer.de [Dresden University of Technology, Institute of Surface and Manufacturing Technology, PO Box, D-01062 Dresden (Germany)

    2011-08-31

    Experimental and theoretical investigations on fibre-laser-assisted plasma arc welding (LAPW) were performed. Welding experiments were carried out on aluminium and steel sheets. In the case of a highly focused laser beam and a separate arrangement of plasma torch and laser beam, high-speed video recordings of the plasma arc and corresponding measurements of the time-dependent arc voltage revealed differences in the process behaviour for both materials. In the case of aluminium welding, a sharp decline in arc voltage and stabilization and guiding of the anodic arc root was observed whereas in steel welding the arc voltage was slightly increased after the laser beam was switched on. However, significant improvement of the melting efficiency with the combined action of plasma arc and laser beam was achieved for both types of material. Theoretical results of additional numerical simulations of the arc behaviour suggest that the properties of the arc plasma are mainly influenced not by a direct interaction with the laser radiation but by the laser-induced evaporation of metal. Arc stabilization with increased current densities is predicted for moderate rates of evaporated metal only whereas metal vapour rates above a certain threshold causes a destabilization of the arc and reduced current densities along the arc axis.

  2. Investigation of dose homogeneity for loose helical tomotherapy delivery in the context of breath-hold radiation therapy

    Science.gov (United States)

    Kim, Bryan; Kron, Tomas; Battista, Jerry; Van Dyk, Jake

    2005-05-01

    Loose helical delivery is a potential solution to account for respiration-driven tumour motion in helical tomotherapy (HT). In this approach, a treatment is divided into a set of interlaced 'loose' helices commencing at different gantry angles. Each loose helix covers the entire target length in one gantry rotation during a single breath-hold. The dosimetric characteristics of loose helical delivery were investigated by delivering a 6 MV photon beam in a HT-like manner. Multiple scenarios of conventional 'tight' HT and loose helical deliveries were modelled in treatment planning software, and carried out experimentally with Kodak EDR2 film. The advantage of loose helical delivery lies in its ability to produce a more homogeneous dose distribution by eliminating the 'thread' effect—an inherent characteristic of HT, which results in dose modulations away from the axis of gantry rotation. However, loose helical delivery was also subjected to undesirable dose modulations in the direction of couch motion (termed 'beating' effect), when the ratio between the number of beam projections per gantry rotation (n) and pitch factor (p) was a non-integer. The magnitude of dose modulations decreased with an increasing n/p ratio. The results suggest that for the current HT unit (n = 51), dose modulations could be kept under 5% by selecting a pitch factor smaller than 7. A pitch factor of this magnitude should be able to treat a target up to 30 cm in length. Loose helical delivery should increase the total session time only by a factor of 2, while the planning time should stay the same since the total number of beam projections remains unchanged. Considering its dosimetric advantage and clinical practicality, loose helical delivery is a promising solution for the future HT treatments of respiration-driven targets.

  3. Volumetric-modulated arc therapy (VMAT versus 3D-conformal radiation therapy in supra-diaphragmatic Hodgkin’s Lymphoma with mediastinal involvement: A dosimetric comparison

    Directory of Open Access Journals (Sweden)

    Christine Higby

    2016-09-01

    Conclusions: VMAT is a valuable technique for treatment of large mediastinal HL. VMAT spares the lung and heart compared to 3DCRT using ISRT in select HL cases. VMAT allows dose escalation for post-chemotherapy residual disease with minimal dose to OARs. VMAT low radiation dose (V5 to the normal tissues, and the increased integral dose should be considered.

  4. Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs

    Energy Technology Data Exchange (ETDEWEB)

    Audet, Chantal; Poffenbarger, Brett A.; Chang, Pauling; Jackson, Paul S.; Lundahl, Robert E.; Ryu, Stephen I.; Ray, Gordon R. [Radiation Oncology Department, Palo Alto Medical Foundation, Palo Alto, California 94301 (United States); Neurosurgery Department, Palo Alto Medical Foundation, Palo Alto, California 94301 (United States); Radiation Oncology Department, Palo Alto Medical Foundation, Palo Alto, California 94301 (United States); Neurosurgery Department, Palo Alto Medical Foundation, Palo Alto, California 94301 (United States); Radiation Oncology Department, Palo Alto Medical Foundation, Palo Alto, California 94301 (United States)

    2011-11-15

    Purpose: To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. Methods: Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multiple metastases patients were planned (Eclipse RapidArc AAA algorithm, v8.6.15) using VMAT (1-6 noncoplanar arcs), dynamic conformal arc (DCA, {approx}4 arcs), and IMRT (nine static fields). All plans were evaluated according to a conformity index (CI), healthy brain tissue doses and volumes, and the dose to organs at risk. A 2D dose distribution was measured (Varian Novalis Tx, HD120 MLC, 1000 MU/min, 6 MV beam) for the {approx}4 arc VMAT treatment plans using calibrated film dosimetry. Results: The CI (0-1 best) average for all plans was best for {approx}4 noncoplanar arc VMAT at 0.86 compared with {approx}0.78 for IMRT and a single arc VMAT and 0.68 for DCA. The volumes of healthy brain receiving 50% of the prescribed target coverage dose or more (V{sub 50%}) were lowest for the four arc VMAT [RA(4)] and DCA plans. The average ratio of the V{sub 50%} for the other plans to the RA(4) V{sub 50%} were 1.9 for a single noncoplanar arc VMAT [RA(1nc)], 1.4 for single full coplanar arc VMAT [RA(1f)] and 1.3 for IMRT. The V{sub 50%} improved significantly for single isocenter multiple metastases plan when two noncoplanar VMAT arcs were added to a full single coplanar one. The maximum dose to 5 cc of the outer 1 cm rim of healthy brain which one may want to keep below nonconsequential doses of 300-400 cGy, was 2-3 times greater for IMRT, RA(1nc) and RA(1f) plans compared with the multiple noncoplanar arc DCA and RA(4) techniques. Organs at risk near (0-4 mm) to targets were best spared by (i) single noncoplanar arcs when the targets are lateral to the organ at risk and (ii) by skewed nonvertical planes of IMRT fields when the targets are not lateral to the

  5. Effect of cathode model on arc attachment for short high-intensity arc on a refractory cathode

    Science.gov (United States)

    Javidi Shirvan, Alireza; Choquet, Isabelle; Nilsson, Håkan

    2016-12-01

    Various models coupling the refractory cathode, the cathode sheath and the arc at atmospheric pressure exist. They assume a homogeneous cathode with a uniform physical state, and differ by the cathode layer and the plasma arc model. However even the most advanced of these models still fail in predicting the extent of the arc attachment when applied to short high-intensity arcs such as gas tungsten arcs. Cathodes operating in these conditions present a non-uniform physical state. A model taking into account the first level of this non-homogeneity is proposed based on physical criteria. Calculations are done for 5 mm argon arcs with a thoriated tungsten cathode. The results obtained show that radiative heating and cooling of the cathode surface are of the same order. They also show that cathode inhomogeneity has a significant effect on the arc attachment, the arc temperature and pressure. When changing the arc current (100 A, 200 A) the proposed model allows predicting trends observed experimentally that cannot be captured by the homogeneous cathode model unless restricting a priori the size of the arc attachment. The cathode physics is thus an important element to include to obtain a comprehensive and predictive arc model.

  6. TH-C-12A-04: Dosimetric Evaluation of a Modulated Arc Technique for Total Body Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Tsiamas, P; Czerminska, M; Makrigiorgos, G; Karen, M; Zygmanski, P [Brigham and Women' s Hospital/ Dana-Farber Institute/ Harvard Medical School, Boston, MA (United States)

    2014-06-15

    Purpose: A simplified Total Body Irradiation (TBI) was developed to work with minimal requirements in a compact linac room without custom motorized TBI couch. Results were compared to our existing fixed-gantry double 4 MV linac TBI system with prone patient and simultaneous AP/PA irradiation. Methods: Modulated arc irradiates patient positioned in prone/supine positions along the craniocaudal axis. A simplified inverse planning method developed to optimize dose rate as a function of gantry angle for various patient sizes without the need of graphical 3D treatment planning system. This method can be easily adapted and used with minimal resources. Fixed maximum field size (40×40 cm2) is used to decrease radiation delivery time. Dose rate as a function of gantry angle is optimized to result in uniform dose inside rectangular phantoms of various sizes and a custom VMAT DICOM plans were generated using a DICOM editor tool. Monte Carlo simulations, film and ionization chamber dosimetry for various setups were used to derive and test an extended SSD beam model based on PDD/OAR profiles for Varian 6EX/ TX. Measurements were obtained using solid water phantoms. Dose rate modulation function was determined for various size patients (100cm − 200cm). Depending on the size of the patient arc range varied from 100° to 120°. Results: A PDD/OAR based beam model for modulated arc TBI therapy was developed. Lateral dose profiles produced were similar to profiles of our existing TBI facility. Calculated delivery time and full arc depended on the size of the patient (∼8min/ 100° − 10min/ 120°, 100 cGy). Dose heterogeneity varied by about ±5% − ±10% depending on the patient size and distance to the surface (buildup region). Conclusion: TBI using simplified modulated arc along craniocaudal axis of different size patients positioned on the floor can be achieved without graphical / inverse 3D planning.

  7. Volumetric Modulated Arc Therapy vs. IMRT for the Treatment of Distal Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Van Benthuysen, Liam, E-mail: liam.vanbenthuysen@roswellpark.org; Hales, Lee; Podgorsak, Matthew B.

    2011-01-01

    Several studies have demonstrated that volumetric modulated arc therapy (VMAT) has the ability to reduce monitor units and treatment time when compared with intensity-modulated radiation therapy (IMRT). This study aims to demonstrate that VMAT is able to provide adequate organs at risk (OAR) sparing and planning target volume (PTV) coverage for adenocarcinoma of the distal esophagus while reducing monitor units and treatment time. Fourteen patients having been treated previously for esophageal cancer were planned using both VMAT and IMRT techniques. Dosimetric quality was evaluated based on doses to several OARs, as well as coverage of the PTV. Treatment times were assessed by recording the number of monitor units required for dose delivery. Body V{sub 5} was also recorded to evaluate the increased volume of healthy tissue irradiated to low doses. Dosimetric differences in OAR sparing between VMAT and IMRT were comparable. PTV coverage was similar for the 2 techniques but it was found that IMRT was capable of delivering a slightly more homogenous dose distribution. Of the 14 patients, 12 were treated with a single arc and 2 were treated with a double arc. Single-arc plans reduced monitor units by 42% when compared with the IMRT plans. Double-arc plans reduced monitor units by 67% when compared with IMRT. The V{sub 5} for the body was found to be 18% greater for VMAT than for IMRT. VMAT has the capability to decrease treatment times over IMRT while still providing similar OAR sparing and PTV coverage. Although there will be a smaller risk of patient movement during VMAT treatments, this advantage comes at the cost of delivering small doses to a greater volume of the patient.

  8. Volumetric modulated arc therapy vs. IMRT for the treatment of distal esophageal cancer.

    Science.gov (United States)

    Van Benthuysen, Liam; Hales, Lee; Podgorsak, Matthew B

    2011-01-01

    Several studies have demonstrated that volumetric modulated arc therapy (VMAT) has the ability to reduce monitor units and treatment time when compared with intensity-modulated radiation therapy (IMRT). This study aims to demonstrate that VMAT is able to provide adequate organs at risk (OAR) sparing and planning target volume (PTV) coverage for adenocarcinoma of the distal esophagus while reducing monitor units and treatment time. Fourteen patients having been treated previously for esophageal cancer were planned using both VMAT and IMRT techniques. Dosimetric quality was evaluated based on doses to several OARs, as well as coverage of the PTV. Treatment times were assessed by recording the number of monitor units required for dose delivery. Body V(5) was also recorded to evaluate the increased volume of healthy tissue irradiated to low doses. Dosimetric differences in OAR sparing between VMAT and IMRT were comparable. PTV coverage was similar for the 2 techniques but it was found that IMRT was capable of delivering a slightly more homogenous dose distribution. Of the 14 patients, 12 were treated with a single arc and 2 were treated with a double arc. Single-arc plans reduced monitor units by 42% when compared with the IMRT plans. Double-arc plans reduced monitor units by 67% when compared with IMRT. The V(5) for the body was found to be 18% greater for VMAT than for IMRT. VMAT has the capability to decrease treatment times over IMRT while still providing similar OAR sparing and PTV coverage. Although there will be a smaller risk of patient movement during VMAT treatments, this advantage comes at the cost of delivering small doses to a greater volume of the patient.

  9. Wire + Arc Additive Manufacturing

    OpenAIRE

    Williams, Stewart W.; Martina, Filomeno; Addison, Adrian C.; Ding, Jialuo; Pardal, Goncalo; Colegrove, Paul A.

    2016-01-01

    Depositing large components (>10 kg) in titanium, aluminium, steel and other metals is possible using Wire + Arc Additive Manufacturing. This technology adopts arc welding tools and wire as feedstock for additive manufacturing purposes. High deposition rates, low material and equipment costs, and good structural integrity make Wire+Arc Additive Manufacturing a suitable candidate for replacing the current method of manufacturing from solid billets or large forgings, especially with regards to ...

  10. Evaluation the implementation of volumetric modulated arc therapy QA in the radiation therapy treatment according to various factors by using the portal dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hyeon; Bae, Sun Myung; Seo, Dong Rin; Kang, Tae Young; Baek, Geum Mun [Dept. of Radiation Oncology, ASAN Medical Center, Seoul (Korea, Republic of)

    2015-12-15

    The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Test was used for TrueBeam STx{sup TM} (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  11. Phase I-II study of hypofractionated simultaneous integrated boost using volumetric modulated arc therapy for adjuvant radiation therapy in breast cancer patients: a report of feasibility and early toxicity results in the first 50 treatments

    Directory of Open Access Journals (Sweden)

    Scorsetti Marta

    2012-08-01

    Full Text Available Abstract Background To report results in terms of feasibility and early toxicity of hypofractionated simultaneous integrated boost (SIB approach with Volumetric Modulated Arc Therapy (VMAT as adjuvant treatment after breast-conserving surgery. Methods Between September 2010 and May 2011, 50 consecutive patients presenting early-stage breast cancer were submitted to adjuvant radiotherapy with SIB-VMAT approach using RapidArc in our Institution (Istituto Clinico Humanitas ICH. Three out of 50 patients were irradiated bilaterally (53 tumours in 50 patients. All patients were enrolled in a phase I-II trial approved by the ICH ethical committee. All 50 patients enrolled in the study underwent VMAT-SIB technique to irradiate the whole breast with concomitant boost irradiation of the tumor bed. Doses to whole breast and surgical bed were 40.5 Gy and 48 Gy respectively, delivered in 15 fractions over 3 weeks. Skin toxicities were recorded during and after treatment according to RTOG acute radiation morbidity scoring criteria with a median follow-up of 12 months (range 8–16. Cosmetic outcomes were assessed as excellent/good or fair/poor. Results The median age of the population was 68 years (range 36–88. According to AJCC staging system, 38 breast lesions were classified as pT1, and 15 as pT2; 49 cases were assessed as N0 and 4 as N1. The maximum acute skin toxicity by the end of treatment was Grade 0 in 20/50 patients, Grade 1 in 32/50, Grade 2 in 0 and Grade 3 in 1/50 (one of the 3 cases of bilateral breast irradiation. No Grade 4 toxicities were observed. All Grade 1 toxicities had resolved within 3 weeks. No significant differences in cosmetic scores on baseline assessment vs. 3 months and 6 months after the treatment were observed: all patients were scored as excellent/good (50/50 compared with baseline; no fair/poor judgment was recorded. No other toxicities or local failures were recorded during follow-up. Conclusions The 3

  12. Welding arc plasma physics

    Science.gov (United States)

    Cain, Bruce L.

    1990-01-01

    The problems of weld quality control and weld process dependability continue to be relevant issues in modern metal welding technology. These become especially important for NASA missions which may require the assembly or repair of larger orbiting platforms using automatic welding techniques. To extend present welding technologies for such applications, NASA/MSFC's Materials and Processes Lab is developing physical models of the arc welding process with the goal of providing both a basis for improved design of weld control systems, and a better understanding of how arc welding variables influence final weld properties. The physics of the plasma arc discharge is reasonably well established in terms of transport processes occurring in the arc column itself, although recourse to sophisticated numerical treatments is normally required to obtain quantitative results. Unfortunately the rigor of these numerical computations often obscures the physics of the underlying model due to its inherent complexity. In contrast, this work has focused on a relatively simple physical model of the arc discharge to describe the gross features observed in welding arcs. Emphasis was placed of deriving analytic expressions for the voltage along the arc axis as a function of known or measurable arc parameters. The model retains the essential physics for a straight polarity, diffusion dominated free burning arc in argon, with major simplifications of collisionless sheaths and simple energy balances at the electrodes.

  13. Single Arc VMAT of H&N cancer

    DEFF Research Database (Denmark)

    Bertelsen, Anders

      Background: A few radiation treatment planning systems are currently able to plan volumetric modulated arc therapy (VMAT). The VMAT algorithm in Pinnacle3 TM is called SmartArc. The capability of SmartArc to generate complex treatment plans for the head and neck (H&N) region was tested...... - when corrected for offset in output - satisfied a gamma criterion of 3mm and 3% of 2Gy compared to 99.7±0.1% for IMRT.   Conclusion: SmartArc generated single arc VMAT plans with improved target coverage and sparing of OARs compared to IMRT. The conformity was increased by VMAT compared to IMRT...... reducing high dose volumes in normal tissues. The VMAT plans used fewer MUs compared to the IMRT plans and reduced the treatment time by approximately 40% compared to IMRT. Both IMRT and VMAT radiation treatment plans delivered on an Elekta Synergy accelerator produced clinically acceptable geometric dose...

  14. SU-E-T-309: Dosimetric Comparison of Simultaneous Integrated Boost Treatment Plan Between Intensity Modulated Radiotherapies (IMRTs), Dual Arc Volumetric Modulated Arc Therapy (DA-VMAT) and Single Arc Volumetric Modulated Arc Therapy (SA-VMAT) for Nasopharyngeal Carcinoma (NPC)

    Energy Technology Data Exchange (ETDEWEB)

    Sivakumar, R; Janardhan, N; Bhavani, P; Surendran, J; Saranganathan, B; Ibrahim, S; Jhonson, B; Madhuri, B [Omega Hospitals, Hyderabad, Telangana (India); Anuradha, C [Vit University, Vellore, Tamil Nadu (India)

    2015-06-15

    Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 in 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered

  15. Synchrotron radiation small- and wide- angle scattering study of dispergation of Equoral, a novel drug delivery system with cyclosporine A.

    Science.gov (United States)

    Uhríková, D; Andrýsek, T; Funari, S S; Balgavý, P

    2004-08-01

    Equoral oral solution is a novel drug delivery system for cyclosporine consisting mainly of non-ionic surfactants, polyglycerol esters and polyoxyethylated fatty acids aggregates, and gives microdispersions in the aqueous enviroment. To simulate dispergation, Equoral was mixed with varying amounts of water. Changes in the structure of the prepared aggregates were studied using synchrotron x-ray small- and wide-angle scattering. A lamellar phase is the most probable structure, arising spontaneously after dispergation of Equoral in the region of 30-70 wt% H2O.

  16. Radiation-induced second primary cancer risks from modern external beam radiotherapy for early prostate cancer: impact of stereotactic ablative radiotherapy (SABR), volumetric modulated arc therapy (VMAT) and flattening filter free (FFF) radiotherapy

    Science.gov (United States)

    Murray, Louise J.; Thompson, Christopher M.; Lilley, John; Cosgrove, Vivian; Franks, Kevin; Sebag-Montefiore, David; Henry, Ann M.

    2015-02-01

    Risks of radiation-induced second primary cancer following prostate radiotherapy using 3D-conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), flattening filter free (FFF) and stereotactic ablative radiotherapy (SABR) were evaluated. Prostate plans were created using 10 MV 3D-CRT (78 Gy in 39 fractions) and 6 MV 5-field IMRT (78 Gy in 39 fractions), VMAT (78 Gy in 39 fractions, with standard flattened and energy-matched FFF beams) and SABR (42.7 Gy in 7 fractions with standard flattened and energy-matched FFF beams). Dose-volume histograms from pelvic planning CT scans of three prostate patients, each planned using all 6 techniques, were used to calculate organ equivalent doses (OED) and excess absolute risks (EAR) of second rectal and bladder cancers, and pelvic bone and soft tissue sarcomas, using mechanistic, bell-shaped and plateau models. For organs distant to the treatment field, chamber measurements recorded in an anthropomorphic phantom were used to calculate OEDs and EARs using a linear model. Ratios of OED give relative radiation-induced second cancer risks. SABR resulted in lower second cancer risks at all sites relative to 3D-CRT. FFF resulted in lower second cancer risks in out-of-field tissues relative to equivalent flattened techniques, with increasing impact in organs at greater distances from the field. For example, FFF reduced second cancer risk by up to 20% in the stomach and up to 56% in the brain, relative to the equivalent flattened technique. Relative to 10 MV 3D-CRT, 6 MV IMRT or VMAT with flattening filter increased second cancer risks in several out-of-field organs, by up to 26% and 55%, respectively. For all techniques, EARs were consistently low. The observed large relative differences between techniques, in absolute terms, were very low, highlighting the importance of considering absolute risks alongside the corresponding relative risks, since when absolute

  17. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    Science.gov (United States)

    Kim, Yon-Lae; Chung, Jin-Beom; Kim, Jae-Sung; Lee, Jeong-Woo; Choi, Kyoung-Sik

    2014-04-01

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ%≤1, γ avg <0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  18. Volumetric modulated arc therapy versus step-and-shoot intensity modulated radiation therapy in the treatment of large nerve perineural spread to the skull base: a comparative dosimetric planning study

    Energy Technology Data Exchange (ETDEWEB)

    Gorayski, Peter; Fitzgerald, Rhys; Barry, Tamara [Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Queensland (Australia); Burmeister, Elizabeth [Nursing Practice Development Unit, Princess Alexandra Hospital and Research Centre for Clinical and Community Practice Innovation, Griffith University, Brisbane, Queensland (Australia); Foote, Matthew [Department of Radiation Oncology, Princess Alexandra Hospital, Woolloongabba, Queensland (Australia); Diamantina Institute, University of Queensland, Brisbane, Queensland (Australia)

    2014-06-15

    Cutaneous squamous cell carcinoma with large nerve perineural (LNPN) infiltration of the base of skull is a radiotherapeutic challenge given the complex target volumes to nearby organs at risk (OAR). A comparative planning study was undertaken to evaluate dosimetric differences between volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) in the treatment of LNPN. Five consecutive patients previously treated with IMRT for LNPN were selected. VMAT plans were generated for each case using the same planning target volumes (PTV), dose prescriptions and OAR constraints as IMRT. Comparative parameters used to assess target volume coverage, conformity and homogeneity included V95 of the PTV (volume encompassed by the 95% isodose), conformity index (CI) and homogeneity index (HI). In addition, OAR maximum point doses, V20, V30, non-target tissue (NTT) point max doses, NTT volume above reference dose, monitor units (MU) were compared. IMRT and VMAT plans generated were comparable for CI (P = 0.12) and HI (P = 0.89). VMAT plans achieved better V95 (P = < 0.001) and reduced V20 and V30 by 652 cubic centimetres (cc) (28.5%) and 425.7 cc (29.1%), respectively. VMAT increased MU delivered by 18% without a corresponding increase in NTT dose. Compared with IMRT plans for LNPN, VMAT achieved comparable HI and CI.

  19. WSTF electrical arc projects

    Science.gov (United States)

    Linley, Larry

    1994-09-01

    The objectives of these projects include the following: validate method used to screen wire insulation with arc tracking characteristics; determine damage resistance to arc as a function of source voltage and insulation thickness; investigate propagation characteristics of Kapton at low voltages; and investigate pyrolytic properties of polyimide insulated (Kapton) wire for low voltage (less than 35 VDC) applications. Supporting diagrams and tables are presented.

  20. Hollow glass and plastic waveguides for the delivery of Er:YAG and CO2 laser radiation

    Science.gov (United States)

    Harrington, James A.; Rabii, Christopher D.; Dobin, Derek E.; Haan, David J.

    1998-01-01

    Hollow glass waveguides are an attractive fiber delivery system for both the 3 micrometers Er:YAG and 10.6 micrometers CO2 lasers. The losses for these waveguides are as low as 0.2 dB/m at CO2 laser wavelengths for guides with a 700 micrometers bore. At the shorter wavelengths of the Er:YAG laser the losses are higher than those predicted theoretically. This is shown to be a result of surface roughness of the inner coatings. These hollow guides are found to have losses which change little with time or cyclic flexure. A new version of these guides made from polycarbonate tubing is described and the losses for these guides are shown to compare favorably with those for the glass guides.

  1. The time-dependent prize-collecting arc routing problem

    DEFF Research Database (Denmark)

    Black, Dan; Eglese, Richard; Wøhlk, Sanne

    2013-01-01

    A new problem is introduced named the Time-Dependent Prize-Collecting Arc Routing Problem (TD-PARP). It is particularly relevant to situations where a transport manager has to choose between a number of full truck load pick-ups and deliveries on a road network where travel times change with the t......A new problem is introduced named the Time-Dependent Prize-Collecting Arc Routing Problem (TD-PARP). It is particularly relevant to situations where a transport manager has to choose between a number of full truck load pick-ups and deliveries on a road network where travel times change...

  2. Circular-Arc Cartograms

    CERN Document Server

    Kämper, Jan-Hinrich; Nöllenburg, Martin

    2011-01-01

    We present a new circular-arc cartogram model in which countries are drawn with circular arcs instead of straight-line segments. Given a geographic map and values associated with each country in the map, the cartogram is a new map in which the areas of the countries represent the corresponding values. In the circular-arc cartogram model straight-line segments can be replaced with circular arcs in order to achieve the desired areas, while the corners of the polygons defining each country remain fixed. The countries in circular-arc cartograms have the aesthetically pleasing appearance of clouds or snowflakes, depending on whether their edges are bent outwards or inwards. This makes is easy to determine whether a country has grown or shrunk, just by its overall shape. We show that determining whether a given map and area-values can be realized with a circular-arc cartogram is an NP-hard problem. Next we describe a heuristic method for constructing circular-arc cartograms, which uses a max-flow computation on the...

  3. Influence of collimator rotation on dose distribution and delivery in intensity modulated radiation therapy for parotid cancer

    Directory of Open Access Journals (Sweden)

    Seema Sharma

    2015-01-01

    Full Text Available Purpose: To evaluate the influence of collimator rotation in IMRT planning with respect to the target coverage and dose to critical structures. In addition, the delivery efficiency of desired fluence with collimator rotation is assessed.Methods: The computed tomography (CT datasets of 5 patients with parotid cancer were employed for this study. Dynamic IMRT plans were generated with a dose prescription of 60 Gy in 30 fractions. IMRT plans were generated with five unilateral fields using 6MV X-rays. Four different plans were generated for each patient by keeping the collimator angle at 0, 30, 60, and 90 degree. All plans were analyzed using dose volume histogram. Conformity index (CI and heterogeneity index (HI were calculated. The total monitor units (MU required to deliver one fraction were noted and compared. To verify the delivery efficiency; the measured fluence on IBA I’mRT MatriXX ionization chamber array detector was compared with the TPS dose plan with 2D gamma evaluation.Results: There is not much difference in the PTV Dmax and Dmean with respect to the different collimator angles. The PTV coverage is best at collimator angle of 0 degree. A slight reduction in CI was observed with plans at other collimator angles as compared to 0 degree. The HI values were almost similar for plans with collimator angle 0, 30, and 60 degree. The plan with 90 degree collimator showed a slightly higher heterogeneity for the PTV. A slight reduction in the average Dmax to spinal cord was observed for the plan with collimator angle 30 degree as compared to other angles whereas maximum value of Dmax to spinal cord was at collimator angle 60 degree. No clinically relevant difference was observed among the plans with respect to brainstem and mandible Dmax. An increase in average of oral cavity Dmax and Dmean was observed for collimator angle 60 and 90 degree as compared to collimator angle 0 and 30 degree. Not much difference was observed with respect to Dmax

  4. Water-vortex-stabilized electric arc: III. Radial energy transport, determination of water-vapour-boundary and arc performance

    Energy Technology Data Exchange (ETDEWEB)

    Jenista, Jiri [Institute of Plasma Physics ASCR, Za Slovankou 3, PO Box 17, Prague 8, 182 21 (Czech Republic)

    2003-12-07

    This paper is concerned with numerical modelling of an electric arc stabilized by a water vortex. The two-dimensional axisymmetric model presented includes the arc discharge area between the cathode and the outlet nozzle of the water plasma torch. The aims of the numerical simulations are: (1) to assess the influence of radial position of the water-vapour-boundary in the discharge chamber on arc performance and overall radial energy transport within the arc; (2) to determine the most probable mass flow rates and radii of the water-vapour-boundary in the discharge chamber for a prescribed current; (3) to demonstrate arc performance for two radiation models involved; and (4) to estimate validity of local thermodynamic equilibrium (LTE) conditions within the arc column. The rate of evaporation of water is calculated from the conduction and radiation heat fluxes at the water vapour surface for the specified mass flow rate. The behaviour of such an arc has been studied for a range of current 300-600 A. It is shown that changes of bulk magnitudes of different terms in the momentum and energy equations within the arc column as a function of arc radius enable us to reveal transitions of temperature and velocity fields from one steady state to a qualitatively different one. The best fit between experiment and numerical simulation for all currents exists for the mean arc radius {approx} 3.3 mm. Deviations from LTE within the arc column are estimated with the criteria for kinetic equilibrium and spatial temperature gradients.

  5. Filtered cathodic arc source

    Science.gov (United States)

    Falabella, Steven; Sanders, David M.

    1994-01-01

    A continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45.degree. to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles.

  6. Pulsed plasma arc cladding

    Institute of Scientific and Technical Information of China (English)

    龙; 白钢; 李振民; 张赋升; 杨思乾

    2004-01-01

    A prototype of Pulsed Plasma Arc Cladding system was developed, in which single power source supplies both transferred plasma arc (TPA) and non-transferred plasma arc (N-TPA). Both plasmas work in turn in a high frequency controlled by an IGBT connecting nozzle and workpiece. The working frequency of IGBT ranges from 50 ~ 7000Hz, in which the plasmas can work in turn smoothly. Higher than 500 Hz of working frequency is suggested for promotion of cladding quality and protection of IGBT. Drag phenomenon of TPA intensifies as the frequency goes up, which tends to increase the current proportion of TPA and suppress N-TPA. The occupation ratio of IGBT can be regulated from 5% ~ 95%, which balances the power supplies of both plasmas. An occupation ratio higher than 50% gives adequate proportion of arc current for N-TPA to preheat powder.

  7. SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Omari, E; Noid, G; Ehlers, C; Erickson, B; Quiroz, F; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States); Cooper, D; Lachaine, M [Elekta Inc., Stockholm (Sweden)

    2015-06-15

    Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by

  8. A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer

    DEFF Research Database (Denmark)

    Gasic, Daniel; Ohlhues, Lars; Brodin, N. Patrik

    2014-01-01

    BACKGROUND: Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time c...

  9. Theory of Parabolic Arcs in Interstellar Scintillation Spectra

    CERN Document Server

    Cordes, J M; Stinebring, D R; Coles, W A; Cordes, James M.; Rickett, Barney J.; Stinebring, Daniel R.; Coles, William A.

    2004-01-01

    Our theory relates the secondary spectrum, the 2D power spectrum of the radio dynamic spectrum, to the scattered pulsar image in a thin scattering screen geometry. Recently discovered parabolic arcs in secondary spectra are generic features for media that scatter radiation at angles much larger than the rms scattering angle. Each point in the secondary spectrum maps particular values of differential arrival-time delay and fringe rate (or differential Doppler frequency) between pairs of components in the scattered image. Arcs correspond to a parabolic relation between these quantities through their common dependence on the angle of arrival of scattered components. Arcs appear even without consideration of the dispersive nature of the plasma. Arcs are more prominent in media with negligible inner scale and with shallow wavenumber spectra, such as the Kolmogorov spectrum, and when the scattered image is elongated along the velocity direction. The arc phenomenon can be used, therefore, to constrain the inner scal...

  10. Single Arc VMAT of H&N cancer

    DEFF Research Database (Denmark)

    Bertelsen, Anders

      Background: A few radiation treatment planning systems are currently able to plan volumetric modulated arc therapy (VMAT). The VMAT algorithm in Pinnacle3 TM is called SmartArc. The capability of SmartArc to generate complex treatment plans for the head and neck (H&N) region was tested...... Target Volumes (PTV). The patients were re-planned with VMAT using the SmartArc algorithm in Pinnacle3TM 8.9c (research version). A constraint for the re-planning was to use only one single arc to create deliverable plans. The objectives were to achieve identical or better target coverage and sparing...... of the organs at risk (OAR) using VMAT compared to IMRT. The comparison was made by evaluating of 1) dose-volume histograms (DVHs) of PTVs and OARs, 2) monitor units, 3) treatment time, and 4) treatment accuracy as delivered on Elekta Synergy accelerators   Results: Preliminary results based on 11 patients...

  11. Designing tragacanth gum based sterile hydrogel by radiation method for use in drug delivery and wound dressing applications.

    Science.gov (United States)

    Singh, Baljit; Varshney, Lalit; Francis, Sanju; Rajneesh

    2016-07-01

    Present article discusses synthesis and characterization of the sterile and pure hydrogel wound dressings which were prepared through radiation method by using polyvinyl alcohol (PVA), tragacanth gum (TG) and sodium alginate (SA). The polymer films were characterized by SEM, Cryo-SEM, FTIR, solid state C(13) NMR and XRD, TGA, and DSC. Some important biological properties such as O2 permeability, water vapor transmission rate, microbial permeability, haemolysis, thrombogenic behavior, antioxidant activity, bio-adhesion and mechanical properties were also studied. The hydrogel film showed thrombogenicity (82.43±1.54%), haemolysis (0.83±0.09%), oxygen permeability (6.433±0.058mg/L) and water vapor permeability (197.39±25.34g/m(2)/day). Hydrogel films were found biocompatible and impermeable to microbes. The release of antibiotic drug moxifloxacin occurred through non-Fickian mechanism and release profile was best fitted in Hixson-Crowell model for drug release. Overall, these results indicate the suitability of these hydrogels in wound dressing applications.

  12. Optimal partial-arcs in VMAT treatment planning

    CERN Document Server

    Wala, Jeremiah; Chen, Wei; Craft, David

    2012-01-01

    Purpose: To improve the delivery efficiency of VMAT by extending the recently published VMAT treatment planning algorithm vmerge to automatically generate optimal partial-arc plans. Methods and materials: A high-quality initial plan is created by solving a convex multicriteria optimization problem using 180 equi-spaced beams. This initial plan is used to form a set of dose constraints, and a set of partial-arc plans is created by searching the space of all possible partial-arc plans that satisfy these constraints. For each partial-arc, an iterative fluence map merging and sequencing algorithm (vmerge) is used to improve the delivery efficiency. Merging continues as long as the dose quality is maintained above a user-defined threshold. The final plan is selected as the partial arc with the lowest treatment time. The complete algorithm is called pmerge. Results: Partial-arc plans are created using pmerge for a lung, liver and prostate case, with final treatment times of 127, 245 and 147 seconds. Treatment times...

  13. Commissioning and first clinical application of mARC treatment

    Energy Technology Data Exchange (ETDEWEB)

    Dzierma, Yvonne; Nuesken, Frank G.; Kremp, Stephanie; Palm, Jan; Licht, Norbert P.; Ruebe, Christian [Universitaetsklinikum des Saarlandes, Klinik fuer Strahlentherapie und Radioonkologie, Homburg, Saarland (Germany)

    2014-11-15

    The modulated arc (mARC) technique has recently been introduced for Siemens ARTISTE linear accelerators. We present the first experiences with the commissioning of the system and first patient treatments. Treatment planning and delivery are presented for the Prowess Panther treatment planning system or, alternatively, an in-house code. Dosimetric verification is performed both by point dose measurements and in 3D dose distribution. Depending on the target volume, one or two arcs can be used to create highly conformal plans. Dosimetric verification of the converted mARC plans with step-and-shoot plans shows deviations below 1 % in absolute point dose; in the 3D dose distribution, over 95 % of the points pass the 3D gamma criteria (3 % deviation in local dose and 3 mm distance to agreement for doses > 20 % of the maximum). Patient specific verification of the mARC dose distribution with the calculations has a similar pass rate. Treatment times range between 2 and 5 min for a single arc. To our knowledge, this is the first report of clinical application of the mARC technique. The mARC offers the possibility to save significant amounts of time, with single-arc treatments of only a few minutes achieving comparable dose distribution to IMRT plans taking up to twice as long. (orig.) [German] Die mARC (modulated arc) Technik wurde vor kurzen fuer Siemens ARTISTE Linearbeschleuniger eingefuehrt. Wir zeigen die ersten Erfahrungen mit der Kommissionierung des Systems sowie die ersten Patientenbestrahlungen. Bestrahlungsplanung und Behandlung werden fuer das Prowess Panther Bestrahlungsplanungssystem oder alternativ in einer in-house-Loesung praesentiert. Die dosimetrische Verifikation wurde sowohl mit Punktmessungen als auch fuer die 3D-Dosisverteilung durchgefuehrt. Je nach Zielvolumen koennen mit einem oder zwei Boegen hochkonformale Plaene erzeugt werden. Die dosimetrische Verifikation konvertierter mARC-Plaene gegen step-and-shoot-Plaene weicht in absoluter Dosis um

  14. The Effect of Flattening Filter Free on Three-dimensional Conformal Radiation Therapy (3D-CRT), Intensity-Modulated Radiation Therapy (IMRT), and Volumetric Modulated Arc Therapy (VMAT) Plans for Metastatic Brain Tumors from Non-small Cell Lung Cancer.

    Science.gov (United States)

    Shi, Li-Wan; Lai, You-Qun; Lin, Qin; Ha, Hui-Ming; Fu, Li-Rong

    2015-07-01

    Flattening filter free (FFF) may affect outcome measures of radiotherapy. The objective of this study is to compare the dosimetric parameters in three types of radiotherapy plans, three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT), with or without the flattening filter (FF), developed for the treatment of metastatic brain tumors from non-small cell lung cancer (NSCLC). From July 2013 to October 2013, 3D-CRT, IMRT, and VMAT treatment plans were designed using 6 MV and 10 MV, with and without FF, for 10 patients with brain metastasis from NSCLC. The evaluation of the treatment plans included homogeneity index (HI), conformity index (CI), monitor units (MU), mean dose (Dmean), treatment time, and the influence of FFF on volumes. There was no difference in CI or HI between FFF and FF models with 3D-CRT, IMRT, and VMAT plans. At 6 MV, a lower Dmean was seen in the FFF model of 3D-CRT and in the VMAT plan at 10 MV. In the IMRT 6 MV, IMRT 10 MV, and VMAT 10 MV plans, higher MUs were seen in the FFF models. FFF treatments are similar in quality to FF plans, generally lead to more monitor units, and are associated with shorter treatment times. FFF plans ranked by the order of superiority in terms of a time advantage are VMAT, 3D-CRT, and IMRT.

  15. Enhancement of survival of 9L gliosarcoma bearing rats following intracerebral delivery of drugs in combination with microbeam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Regnard, Pierrick [Biomedical Facility, 6, Rue Jules Horowitz, ESRF, BP220, F 38043 Grenoble (France); Braeuer-Krisch, Elke [Biomedical Beamline, ESRF, BP220, F 38043 Grenoble (France); Tropres, Irene [IFR1, Universite Joseph Fourier, 3T MRI unit, CHU A Michallon, BP217, F 38043 Grenoble (France); Keyrilaeinen, Jani; Bravin, Alberto [Biomedical Beamline, ESRF, BP220, F 38043 Grenoble (France); Le Duc, Geraldine [Biomedical Facility, 6, Rue Jules Horowitz, ESRF, BP220, F 38043 Grenoble (France)], E-mail: leduc@esrf.fr

    2008-12-15

    Microbeam radiation therapy (MRT) is a form of radiosurgery first dedicated to the treatment of brain tumors. It uses arrays of synchrotron generated X-rays microbeams of very high doses (typically 625 Gy). Microbeams are typically few micrometers large (25 {mu}m) and few hundred micrometers spaced (200 {mu}m). Previous experiments have shown that despite a good tumor eradication rate (5/11), a 100-{mu}m spacing unidirectional irradiation (skin dose 625 Gy, width 25 {mu}m) was too invasive for normal tissue. On the contrary, a 200-{mu}m spacing unidirectional irradiation preserved healthy tissue with a low tumor eradication rate (2/32). The purpose of this study was to enhance the potential of the 200 {mu}m spacing irradiation protocol. After diagnosis of the tumor by MRI, 9L tumor-bearing rats were laterally irradiated with 51 microbeams (625 Gy, 25 {mu}m, 200 {mu}m) 14 days after implantation. Three drugs (Gd-DTPA, CisPt, temozolomide) were tested, after intratumoral injection at the theoretical center of the tumor. Control rats displayed a median survival time of 19 days. There was no significant difference between drug-treated rats and control group. Irradiated animals showed an increase in life span (ILS) of 60.5%. Interestingly, the ILS increased to 131.6% and 1/6 rat survived more than 1 year in case of MRT combined with gadolinium injection. These results showed that the synergy between gadolinium injection (acting as a dose enhancer) and MRT improved significantly the life span of tumor bearing rats (more than a factor 2)

  16. Accelerated hypofractionated adjuvant whole breast radiation with simultaneous integrated boost using volumetric modulated arc therapy for early breast cancer: A phase I/II dosimetric and clinical feasibility study from a tertiary cancer care centre of India

    Directory of Open Access Journals (Sweden)

    Dodul Mondal

    2017-03-01

    Mini abstract: Simultaneous integrated boost with accelerated hypofractionated whole breast radiotherapy using Volumetric Modulated Arc Therapy is a novel approach. Patient selection and technical considerations are of paramount importance. The present study describes successful implementation of this approach.

  17. Modeling of Arc Force in Plasma Arc Welding

    Institute of Scientific and Technical Information of China (English)

    GAO Zhonglin; HU Shengsun; YIN Fengliang; WANG Rui

    2008-01-01

    A three. dimensional mathematical model for the transferred-type argon arc was developed to describe arc force on the anode surface. The software ANSYS was employed to solve the model. The model includes a part of torch and tungsten electrode to achieve m ore reasonable results. The arc temperature and flow fields were derived. And the influences of welding parameters on arc force were also studied. The simulated results show that arc pressure at the anode are dependent on the welding current, plasma gas flow rate and electrode neck-in, while not sensitive to arc length.

  18. Early clinical experience of radiotherapy of prostate cancer with volumetric modulated arc therapy

    Directory of Open Access Journals (Sweden)

    Valli Mariacarla

    2010-06-01

    Full Text Available Abstract Background To report about initial clinical experience in radiation treatment of carcinoma of prostate with volumetric modulated arcs with the RapidArc (RA technology. Methods Forty-five patients with a median age of 72 ± 3, affected by prostate carcinoma (T1c: 22 patients, T2a-b: 17 patients, T3a-b: 6 patients. N0: 43 patients, N1-Nx: 2 patients, all M0, with initial PSA of 10.0 ± 3.0 ng/mL, were treated with RapidArc in a feasibility study. All patients were treated with single arc using 6MV photons. Dose prescription ranged between 76 (7 patients and 78 Gy (38 patients in 2Gy/fraction. Plan quality was assessed by means of Dose Volume Histogram (DVH analysis. Technical parameters of arcs and pre-treatment quality assurance results (Gamma Agreement Index, GAI are reported to describe delivery features. Early toxicity was scored (according to the Common Terminology Criteria of Adverse Effects scale, CTCAE, scale at the end of treatment together with biochemical outcome (PSA. Results From DVH data, target coverage was fulfilling planning objectives: V95% was in average higher than 98% and V107%~0.0% (D2%~104.0% in average. Homogeneity D5%-D95% ranged between 6.2 ± 1.0% to 6.7 ± 1.3%. For rectum, all planning objectives were largely met (e.g. V70Gy = 10.7 ± 5.5% against an objective of 2% = 79.4 ± 1.2Gy against an objective of 80.0Gy. Maximum dose to femurs was D2% = 36.7 ± 5.4Gy against an objective of 47Gy. Monitor Units resulted: MU/Gy = 239 ± 37. Average beam on time was 1.24 ± 0.0 minutes. Pre-treatment GAI resulted in 98.1 ± 1.1%. Clinical data were recorded as PSA at 6 weeks after RT, with median values of 0.4 ± 0.4 ng/mL. Concerning acute toxicity, no patient showed grade 2-3 rectal toxicity; 5/42 (12% patients experienced grade 2 dysuria; 18/41 (44% patients preserved complete or partial erectile function. Conclusion RapidArc proved to be a safe, qualitative and advantageous treatment modality for prostate cancer.

  19. Skin dose differences between intensity-modulated radiation therapy and volumetric-modulated arc therapy and between boost and integrated treatment regimens for treating head and neck and other cancer sites in patients

    Energy Technology Data Exchange (ETDEWEB)

    Penoncello, Gregory P.; Ding, George X., E-mail: george.ding@vanderbilt.edu

    2016-04-01

    The purpose of this study was (1) to evaluate dose to skin between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques for target sites in the head and neck, pelvis, and brain and (2) to determine if the treatment dose and fractionation regimen affect the skin dose between traditional sequential boost and integrated boost regimens for patients with head and neck cancer. A total of 19 patients and 48 plans were evaluated. The Eclipse (v11) treatment planning system was used to plan therapy in 9 patients with head and neck cancer, 5 patients with prostate cancer, and 5 patients with brain cancer with VMAT and static-field IMRT. The mean skin dose and the maximum dose to a contiguous volume of 2 cm{sup 3} for head and neck plans and brain plans and a contiguous volume of 5 cm{sup 3} for pelvis plans were compared for each treatment technique. Of the 9 patients with head and neck cancer, 3 underwent an integrated boost regimen. One integrated boost plan was replanned with IMRT and VMAT using a traditional boost regimen. For target sites located in the head and neck, VMAT reduced the mean dose and contiguous hot spot most noticeably in the shoulder region by 5.6% and 5.4%, respectively. When using an integrated boost regimen, the contiguous hot spot skin dose in the shoulder was larger on average than a traditional boost pattern by 26.5% and the mean skin dose was larger by 1.7%. VMAT techniques largely decrease the contiguous hot spot in the skin in the pelvis by an average of 36% compared with IMRT. For the same target coverage, VMAT can reduce the skin dose in all the regions of the body, but more noticeably in the shoulders in patients with head and neck and pelvis cancer. We also found that using integrated boost regimens in patients with head and neck cancer leads to higher shoulder skin doses compared with traditional boost regimens.

  20. ARc Welding (Industrial Processing Series).

    Science.gov (United States)

    ARC WELDING , *BIBLIOGRAPHIES), (*ARC WELDS, BIBLIOGRAPHIES), ALUMINUM ALLOYS, TITANIUM ALLOYS, CHROMIUM ALLOYS, METAL PLATES, SPOT WELDING , STEEL...INERT GAS WELDING , MARAGING STEELS, MICROSTRUCTURE, HEAT RESISTANT ALLOYS, HEAT RESISTANT METALS, WELDABILITY, MECHANICAL PROPERTIES, MOLYBDENUM ALLOYS, NICKEL ALLOYS, RESISTANCE WELDING

  1. Arc Heated Scramjet Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Arc Heated Scramjet Test Facility is an arc heated facility which simulates the true enthalpy of flight over the Mach number range of about 4.7 to 8 for free-jet...

  2. Clinical utility of RapidArcTM radiotherapy technology

    Directory of Open Access Journals (Sweden)

    Infusino E

    2015-11-01

    Full Text Available Erminia Infusino Department of Radiotherapy, Campus Bio-Medico University Hospital, Rome, Italy Abstract: RapidArcTM is a radiation technique that delivers highly conformal dose distributions through the complete rotation (360° and speed variation of the linear accelerator gantry. This technique, called volumetric modulated arc therapy (VMAT, compared with conventional radiotherapy techniques, can achieve high-target volume coverage and sparing damage to normal tissues. RapidArc delivers precise dose distribution and conformity similar to or greater than intensity-modulated radiation therapy in a short time, generally a few minutes, to which image-guided radiation therapy is added. RapidArc has become a currently used technology in many centers, which use RapidArc technology to treat a large number of patients. Large and small hospitals use it to treat the most challenging cases, but more and more frequently for the most common cancers. The clinical use of RapidArc and VMAT technology is constantly growing. At present, a limited number of clinical data are published, mostly concerning planning and feasibility studies. Clinical outcome data are increasing for a few tumor sites, even if only a little. The purpose of this work is to discuss the current status of VMAT techniques in clinical use through a review of the published data of planning systems and clinical outcomes in several tumor sites. The study consisted of a systematic review based on analysis of manuscripts retrieved from the PubMed, BioMed Central, and Scopus databases by searching for the keywords "RapidArc", "Volumetric modulated arc radiotherapy", and "Intensity-modulated radiotherapy". Keywords: IMRT, VMAT, SBRT, SRS, treatment planning software 

  3. Accelerated partial breast irradiation: Using the CyberKnife as the radiation delivery platform in the treatment of early breast cancer

    Directory of Open Access Journals (Sweden)

    Sandra eVermeulen

    2011-11-01

    Full Text Available We evaluate the CyberKnife (Accuray, Incorporated, Sunnyvale, CA for non-invasive delivery of accelerated partial breast irradiation (APBI in early breast cancer patients. Between 6/2009 and 5/2011, 9 patients were treated with CyberKnife APBI. Normal tissue constraints were imposed as outlined in the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 (NSABP/RTOG Protocol (Vicini and White, 2007. Patients received a total dose of 30 Gy in 5 fractions (group 1, n=2 or 34 Gy in 10 fractions (group 2, n=7 delivered to the planning treatment volume (PTV defined as the clinical target volume (CTV + 2 mm. The CTV was defined as either the lumpectomy cavity plus 10 mm (n=2 or 15 mm (n=7. The cavity was defined by a T2-weighted non-contrast breast MRI fused to a planning non-contrast thoracic CT. The CyberKnife Synchrony system tracked gold fiducials sutured into the cavity wall during lumpectomy. Treatments started 4-5 weeks after lumpectomy. The mean PTV was 100 cm3 (range, 92-108 cm3 and 105 cm3 (range, 49-241 cm3 and the mean PTV isodose prescription line was 70% for groups 1 and 2, respectively. The mean percent of whole breast reference volume receiving 100% and 50% of the dose (V100 and V50 for group 1 was 11% (range, 8-13% and 23% (range, 16-30% and for group 2 was 11% (range, 7-14% and 26% (range, 21- 35.0% , respectively. At a median 7 months follow-up (range, 4-26 months, no acute toxicities were seen. Acute cosmetic outcomes were excellent or good in all patients; for those patients with more than 12 months follow-up the late cosmesis outcomes were excellent or good. In conclusion, the lack of observable acute side effects and current excellent/good cosmetic outcomes is promising. We believe this suggests the CyberKnife is a suitable non-invasive radiation platform for delivering APBI with achievable normal tissue constraints.

  4. ALICE-ARC integration

    DEFF Research Database (Denmark)

    Anderlik, Csaba; Gregersen, Anders Rhod; Kleist, Josva;

    2008-01-01

    Data Grid Facility (NDGF). In this paper we will present our approach to integrate AliEn and ARC, in the sense that ALICE data management and job processing can be carried out on the NDGF infrastructure, using the client tools available in AliEn. The interoperation has two aspects, one is the data...

  5. Thermal Arc Spray Overview

    Science.gov (United States)

    Hafiz Abd Malek, Muhamad; Hayati Saad, Nor; Kiyai Abas, Sunhaji; Mohd Shah, Noriyati

    2013-06-01

    Usage of protective coating for corrosion protection was on highly demand during the past decade; and thermal spray coating played a major part during that time. In recent years, the thermal arc spray coating becomes a popular coating. Many big players in oil and gas such as PETRONAS, EXXON MOBIL and SHELL in Malaysia tend to use the coating on steel structure as a corrosion protection. Further developments in coating processes, the devices, and raw materials have led to expansion of functional coatings and applications scope from conventional coating to specialized industries. It is widely used because of its ability to withstand high process temperature, offer advantages in efficiency, lower cost and acts as a corrosion protection. Previous research also indicated that the thermal arc spray offers better coating properties compared to other methods of spray. This paper reviews some critical area of thermal spray coating by discussing the process/parameter of thermal arc spray technology and quality control of coating. Coating performance against corrosion, wear and special characteristic of coating are also described. The field application of arc spray technology are demonstrated and reviewed.

  6. Variable polarity arc welding

    Science.gov (United States)

    Bayless, E. O., Jr.

    1991-01-01

    Technological advances generate within themselves dissatisfactions that lead to further advances in a process. A series of advances in welding technology which culminated in the Variable Polarity Plasma Arc (VPPA) Welding Process and an advance instituted to overcome the latest dissatisfactions with the process: automated VPPA welding are described briefly.

  7. Gas tungsten arc welder

    Science.gov (United States)

    Christiansen, D.W.; Brown, W.F.

    A welder for automated closure of fuel pins by a gas tungsten arc process in which a rotating length of cladding is positioned adjacent a welding electrode in a sealed enclosure. An independently movable axial grinder is provided in the enclosure for refurbishing the used electrode between welds.

  8. Motion of polar cap arcs

    Science.gov (United States)

    Hosokawa, K.; Moen, J. I.; Shiokawa, K.; Otsuka, Y.

    2011-01-01

    A statistics of motion of polar cap arcs is conducted by using 5 years of optical data from an all-sky imager at Resolute Bay, Canada (74.73°N, 265.07°E). We identified 743 arcs by using an automated arc detection algorithm and statistically examined their moving velocities as estimated by the method of Hosokawa et al. (2006). The number of the arcs studied is about 5 times larger than that in the previous statistics of polar cap arcs by Valladares et al. (1994); thus, we could expect to obtain more statistically significant results. Polar cap arcs are found to fall into two distinct categories: the By-dependent and By-independent arcs. The motion of the former arcs follows the rule reported by Valladares et al. (1994), who showed that stable polar cap arcs move in the direction of the interplanetary magnetic field (IMF) By. About two thirds of the arcs during northward IMF conditions belong to this category. The latter arcs always move poleward irrespective of the sign of the IMF By, which possibly correspond to the poleward moving arcs in the morning side reported by Shiokawa et al. (1997). At least one third of the arcs belong to this category. The By-dependent arcs tend to move faster when the magnitude of the IMF By is larger, suggesting that the transport of open flux by lobe reconnection from one polar cap compartment to the other controls their motion. In contrast, the speed of the By-independent arcs does not correlate with the magnitude of the By. The motions of both the By-dependent and By-independent arcs are most probably caused by the magnetospheric convection. Convection in the region of By-dependent arcs is affected by the IMF By, which indicates that their sources may be on open field lines or in the closed magnetosphere adjacent to the open-closed boundary, whereas By-independent arcs seem to be well on closed field lines. Hence, the magnetospheric source of the two types of arc may be different. This implies that the mechanisms causing the

  9. Numerical Modeling of Electric Arcs with Water Vortex and Hybrid Stabilizations

    Science.gov (United States)

    Jeništa, J.; Bartlová, M.; Aubrecht, V.

    2008-02-01

    In this paper we deal with numerical investigation of properties and processes occurring in the electric arcs with tangential stabilization of electric arc by water vortex (Gerdien arc) and with the combined stabilization of arc by axial gas flow and water vortex. The net emission coefficient and the partial characteristics method for radiation loss from these arcs are employed. Results carried out for the water arc for 150-600 A proved that typical outlet velocities are 0.7-8 km s-1, temperatures 14 000 K-26 000 K, the voltage drop 110-200 V, the pressure drop 0.02-0.4 atm. and the Mach numbers range from 0.1 to 0.8. The partial characteristics model gives a lower value of radiation loss from the arc than the net emission model, implying higher outlet velocities and temperatures, closer to experimental values. The hybrid arc exhibits higher outlet velocities under the practically unchanged plasma enthalpy compared to Gerdien arc. The contribution of O2, H2 and OH molecular bands to the amount of reabsorbed radiation has been also discussed. Comparison between present calculation and available experiments carried out at the Institute shows a good agreement.

  10. ALICE - ARC integration

    DEFF Research Database (Denmark)

    Anderlik, Csaba; Gregersen, Anders Rhod; Kleist, Josva;

    AliEn or Alice Environment is the Gridware developed and used within the ALICE collaboration for storing and processing data in a distributed manner. ARC (Advanced Resource Connector) is the Grid middleware deployed across the Nordic countries and gluing together the resources within the Nordic...... Data Grid Facility (NDGF). In this paper we will present our approach to integrate AliEn and ARC, in the sense that ALICE data management and job processing can be carried out on the NDGF infrastructure, using the client tools available in AliEn. The interoperation has two aspects, one is the data...... management part and the second the job management aspect. The first aspect was solved by using dCache across NDGF to handle data. dCache provides support for several data management tools (among them for xrootd the tools used by AliEn) using the so called "doors". Therefore, we will concentrate on the second...

  11. Modeling rf breakdown arcs

    CERN Document Server

    Insepov, Zeke; Huang, Dazhang; Mahalingam, Sudhakar; Veitzer, Seth

    2010-01-01

    We describe breakdown in 805 MHz rf accelerator cavities in terms of a number of mechanisms. We devide the breakdown process into three stages: (1) we model surface failure using molecular dynamics of fracture caused by electrostatic tensile stress, (2) we model the ionization of neutrals responsible for plasma initiation and plasma growth using a particle in cell code, and (3) we model surface damage by assuming a process similar to unipolar arcing. Although unipolar arcs are strictly defined with equipotential boundaries, we find that the cold, dense plasma in contact with the surface produces very small Debye lengths and very high electric fields over a large area. These high fields produce strong erosion mechanisms, primarily self sputtering, compatible with the crater formation that we see. Results from the plasma simulation are included as a guide to experimental verification of this model.

  12. Polymer matrices obtained by ionizing radiation for using in controlled drug delivery systems; Matrizes polimericas obtidas mediante radiacao ionizante para sua utilizacao como sistemas de liberacao controlada de farmacos

    Energy Technology Data Exchange (ETDEWEB)

    Martellini, Flavia

    1998-07-01

    Two kinds of controlled drug delivery system were obtained by gamma radiation induced polymerization. One of the system was obtained from an acrylic derivative of acetaminophen (40-hydroxyacetanilide), by copolymerization of 4-(acryloyloxy) acetanilide and N,N-dimethylacrylamide (DMAA) in dimethylformamide solution with 0,16 kGy/h dose rate and 54 Gy dose. The values of reactivity rate, r-D{sub MAA} = 0,31 {+-} 0,02 e r{sub AOA} -0,07 {+-} 0,12, were determined by Fineman-Ross method. The acetaminophen hydrolysis was carried out in alkaline and enzymatic (trypsin) media. Another kind of drug delivery system studied was solvent controlled type, being the drug immobilized in the hydrogel,. The hydrogels prepared by radiation polymerization of acryloyl-L-propine methylester (A-Pro-OMe) with 10 Gy dose, showed thermosensible property, swelling or shrinking in water with decreased or increased temperatures. The hydrogels were obtained with different crosslink density, trimethylolpropane trimethacrylate, and the monomers N, N-dimethyl acrylamide (DMAA) and 2-cyanoethyl acrylate to study the influence of the composition in the drug delivery rate. It was verified that the porous size besides being a characteristic of the matrix composition, it was also temperature dependent (thermosensible). The analgesic drug acetaminophen was immobilized by entrapment and by physical adsorption into the hydrogels matrices for 'in vitro' study. The insulin was immobilized by adsorption for 'in vivo' study. (author)

  13. The ARCS radial collimator

    OpenAIRE

    Stone M.B.; Niedziela J.L.; Overbay M.A.; Abernathy D.L.

    2015-01-01

    We have designed, installed, and commissioned a scattered beam radial collimator for use at the ARCS Wide Angular Range Chopper Spectrometer at the Spallation Neutron Source. The collimator has been designed to work effectively for thermal and epithermal neutrons and with a range of sample environments. Other design considerations include the accommodation of working within a high vacuum environment and having the ability to quickly install and remove the collimator from the scattered beam. W...

  14. Circular arc structures

    KAUST Repository

    Bo, Pengbo

    2011-07-01

    The most important guiding principle in computational methods for freeform architecture is the balance between cost efficiency on the one hand, and adherence to the design intent on the other. Key issues are the simplicity of supporting and connecting elements as well as repetition of costly parts. This paper proposes so-called circular arc structures as a means to faithfully realize freeform designs without giving up smooth appearance. In contrast to non-smooth meshes with straight edges where geometric complexity is concentrated in the nodes, we stay with smooth surfaces and rather distribute complexity in a uniform way by allowing edges in the shape of circular arcs. We are able to achieve the simplest possible shape of nodes without interfering with known panel optimization algorithms. We study remarkable special cases of circular arc structures which possess simple supporting elements or repetitive edges, we present the first global approximation method for principal patches, and we show an extension to volumetric structures for truly threedimensional designs. © 2011 ACM.

  15. Modeling treatment couches in the Pinnacle treatment planning system: Especially important for arc therapy.

    Science.gov (United States)

    Duggar, William Neil; Nguyen, Alex; Stanford, Jason; Morris, Bart; Yang, Claus C

    2016-01-01

    This study is to demonstrate the importance and a method of properly modeling the treatment couch for dose calculation in patient treatment using arc therapy. The 2 treatment couch tops-Aktina AK550 and Elekta iBEAM evo-of Elekta LINACs were scanned using Philips Brilliance Big Bore CT Simulator. Various parts of the couch tops were contoured, and their densities were measured and recorded on the Pinnacle treatment planning system (TPS) using the established computed tomography density table. These contours were saved as organ models to be placed beneath the patient during planning. Relative attenuation measurements were performed following procedures outlined by TG-176 as well as absolute dose comparison of static fields of 10 × 10 cm(2) that were delivered through the couch tops with that calculated in the TPS with the couch models. A total of 10 random arc therapy treatment plans (5 volumetric-modulated arc therapy [VMAT] and 5 stereotactic body radiation therapy [SBRT]), using 24 beams, were selected for this study. All selected plans were calculated with and without couch modeling. Each beam was evaluated using the Delta(4) dosimetry system (Delta(4)). The Student t-test was used to determine statistical significance. Independent reviews were exploited as per the Imaging and Radiation Oncology Core head and neck credentialing phantom. The selected plans were calculated on the actual patient anatomies with and without couch modeling to determine potential clinical effects. Large relative beam attenuations were noted dependent on which part of the couch top beams were passing through. Substantial improvements were also noted for static fields both calculated with the TPS and delivered physically when the couch models were included in the calculation. A statistically significant increase in agreement was noted for dose difference, distance to agreement, and γ-analysis with the Delta(4) on VMAT and SBRT plans. A credentialing review showed improvement in

  16. Planning study of flattening filter free beams for volumetric modulated arc therapy in squamous cell carcinoma of the scalp.

    Directory of Open Access Journals (Sweden)

    Youqun Lai

    Full Text Available Flattening filter free (FFF beams show the potential for a higher dose rate and lower peripheral dose. We investigated the planning study of FFF beams with their role for volumetric modulated arc therapy (VMAT in squamous cell carcinoma of the scalp.One patient with squamous cell carcinoma which had involvement of entire scalp was subjected to VMAT using TrueBeam linear accelerator. As it was a rare skin malignancy, CT data of 7 patients with brain tumors were also included in this study, and their entire scalps were outlined as target volumes. Three VMAT plans were employed with RapidArc form: two half-field full-arcs VMAT using 6 MV standard beams (HFF-VMAT-FF, eight half-field quarter-arcs VMAT using 6 MV standard beams (HFQ-VMAT-FF, and HFQ-VMAT using FFF beams (HFQ-VMAT-FFF. Prescribed dose was 25 × 2 Gy (50 Gy. Plan quality and efficiency were assessed for all plans.There were no statistically significant differences among the three VMAT plans in target volume coverage, conformity, and homogeneity. For HFQ-VMAT-FF plans, there was a significant decrease by 12.6% in the mean dose to the brain compared with HFF-VMAT-FF. By the use of FFF beams, the mean dose to brain in HFQ-VMAT-FFF plans was further decreased by 7.4% compared with HFQ-VMAT-FF. Beam delivery times were similar for each technique.The HFQ-VMAT-FF plans showed the superiority in dose distributions compared with HFF-VMAT-FF. HFQ-VMAT-FFF plans might provide further normal tissue sparing, particularly in the brain, showing their potential for radiation therapy in squamous cell carcinoma of the scalp.

  17. Comparative analysis of volumetric-modulated arc therapy and intensity-modulated radiotherapy for base of tongue cancer

    Directory of Open Access Journals (Sweden)

    L Nithya

    2014-01-01

    Full Text Available The aim of this study was to compare the various dosimetric parameters of dynamic multileaf collimator (MLC intensity modulated radiation therapy (IMRT plans with volumetric modulated arc therapy (VMAT plans for base of tongue cases. All plans were done in Monaco planning system for Elekta synergy linear accelerator with 80 MLC. IMRT plans were planned with nine stationary beams, and VMAT plans were done for 360° arc with single arc or dual arc. The dose to the planning target volumes (PTV for 70, 63, and 56 Gy was compared. The dose to 95, 98, and 50% volume of PTV were analyzed. The homogeneity index (HI and the conformity index (CI of the PTV 70 were also analyzed. IMRT and VMAT plan showed similar dose coverage, HI, and CI. Maximum dose and dose to 1-cc volume of spinal cord, planning risk volume (PRV cord, and brain stem were compared. IMRT plan and VMAT plan showed similar results except for the 1 cc of PRV cord that received slightly higher dose in VMAT plan. Mean dose and dose to 50% volume of right and left parotid glands were analyzed. VMAT plan gave better sparing of parotid glands than IMRT. In normal tissue dose analyses VMAT was better than IMRT. The number of monitor units (MU required for delivering the good quality of the plan and the time required to deliver the plan for IMRT and VMAT were compared. The number of MUs for VMAT was higher than that of IMRT plans. However, the delivery time was reduced by a factor of two for VMAT compared with IMRT. VMAT plans yielded good quality of the plan compared with IMRT, resulting in reduced treatment time and improved efficiency for base of tongue cases.

  18. Arc-preserving subsequences of arc-annotated sequences

    CERN Document Server

    Popov, Vladimir Yu

    2011-01-01

    Arc-annotated sequences are useful in representing the structural information of RNA and protein sequences. The longest arc-preserving common subsequence problem has been introduced as a framework for studying the similarity of arc-annotated sequences. In this paper, we consider arc-annotated sequences with various arc structures. We consider the longest arc preserving common subsequence problem. In particular, we show that the decision version of the 1-{\\sc fragment LAPCS(crossing,chain)} and the decision version of the 0-{\\sc diagonal LAPCS(crossing,chain)} are {\\bf NP}-complete for some fixed alphabet $\\Sigma$ such that $|\\Sigma| = 2$. Also we show that if $|\\Sigma| = 1$, then the decision version of the 1-{\\sc fragment LAPCS(unlimited, plain)} and the decision version of the 0-{\\sc diagonal LAPCS(unlimited, plain)} are {\\bf NP}-complete.

  19. SU-E-T-136: Dosimetric Robustness of a Magnetic Resonance Imaging Guided Radiation Therapy (MR-IGRT) System

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, V; Green, O; Wooten, H; Kashani, R; Mutic, S; Li, H [Washington University School of Medicine, St. Louis, MO (United States); Dempsey, J [View Ray Incorporated, Oakwood Village, OH (United States)

    2014-06-01

    Purpose: To test the radiation delivery robustness of the first MR-IGRT system using a commercial cylindrical diode array detector (ArcCHECK) and an ionization thimble chamber (Exradin A18). Methods: The MR-IGRT system is composed of three evenly spaced Co-60 sources on a rotating gantry located between two magnet halves. The collimator for each source consists of 30 doubly-focused leaf pairs that allow the system to deliver both conformal and intensity modulated (IMRT) treatment plans. The system's delivery robustness was tested over a span of 6 months from September 2013 through February 2014. This was achieved by repeatedly delivering 10 patient plans. These plans consisted of 2 conformal prostates, 2 IMRT prostates, 2 IMRT head and neck, 2 IMRT breast, 1 IMRT pancreas, and 1 IMRT bladder. The plans were generated with the system's treatment planning software. Once the plans were generated, quality assurance plans were created on a digital ArcCHECK dataset. The ArcCHECK used for testing was specially designed to be MR-compatible by moving the power supply outside of the magnetic field. The A18 ionization chamber was placed in a custom plastic plug insert in the center of the ArcCHECK. Gamma analysis was used with the ArcCHECK for relative dose evaluating both 3%/3mm and 2%/2mm. Absolute point dose was compared between ion chamber measurement and treatment plan. Results: The ArcCHECK passing rate remained constant over the 6 month period. The average passing rate for 3%/3mm and 2%/2mm analysis was 98.6% ± 0.7 and 88.8% ± 2.9, respectively. The ion chamber measurements showed little variation with an average percent difference between planned dose verses measured dose of 0.9% ± 0.7. Conclusion: Minimal differences were noted in the delivery of the 10 patient plans. Over a period that included acceptance testing, commissioning, and clinical deliveries, the MR-IGRT system remained consistent in radiation delivery.

  20. Forceps Delivery

    Science.gov (United States)

    ... delivery. If your health care provider does an episiotomy — an incision in the tissue between the vagina ... the tissue between your vagina and your anus (episiotomy) to help ease the delivery of your baby. ...

  1. Accuracy of one algorithm used to modify a planned DVH with data from actual dose delivery.

    Science.gov (United States)

    Ma, Tianjun; Podgorsak, Matthew B; Kumaraswamy, Lalith K

    2016-09-08

    Detection and accurate quantification of treatment delivery errors is important in radiation therapy. This study aims to evaluate the accuracy of DVH based QA in quantifying delivery errors. Eighteen previously treated VMAT plans (prostate, H&N, and brain) were randomly chosen for this study. Conventional IMRT delivery QA was done with the ArcCHECK diode detector for error-free plans and plans with the following modifications: 1) induced monitor unit differences up to ± 3.0%, 2) control point deletion (3, 5, and 8 control points were deleted for each arc), and 3) gantry angle shift (2° uniform shift clockwise and counterclockwise). 2D and 3D distance-to-agreement (DTA) analyses were performed for all plans with SNC Patient software and 3DVH software, respectively. Subsequently, accuracy of the reconstructed DVH curves and DVH parameters in 3DVH software were analyzed for all selected cases using the plans in the Eclipse treatment planning system as standard. 3D DTA analysis for error-induced plans generally gave high pass rates, whereas the 2D evaluation seemed to be more sensitive to detecting delivery errors. The average differences for DVH parameters between each pair of Eclipse recalculation and 3DVH prediction were within 2% for all three types of error-induced treatment plans. This illustrates that 3DVH accurately quantifies delivery errors in terms of actual dose delivered to the patients. 2D DTA analysis should be routinely used for clinical evaluation. Any concerns or dose discrepancies should be further analyzed through DVH-based QA for clinically relevant results and confirmation of a conventional passing-rate-based QA.

  2. Heat Transfer Analysis for Industrial AC Electric Arc Furnace

    Institute of Scientific and Technical Information of China (English)

    (U)nal (C)amdali; Murat Tun(c)

    2005-01-01

    The heat transfer analysis was performed for an AC electric arc furnace (EAF). Heat losses by conduction, convection and radiation from outer surface, roof, bottom and electrodes of EAF were determined in detail. Some suggestions about decreasing heat losses were presented.

  3. Hybrid laser-arc welding

    DEFF Research Database (Denmark)

    Hybrid laser-arc welding (HLAW) is a combination of laser welding with arc welding that overcomes many of the shortfalls of both processes. This important book gives a comprehensive account of hybrid laser-arc welding technology and applications. The first part of the book reviews...... the characteristics of the process, including the properties of joints produced by hybrid laser-arc welding and ways of assessing weld quality. Part II discusses applications of the process to such metals as magnesium alloys, aluminium and steel as well as the use of hybrid laser-arc welding in such sectors as ship...... building and the automotive industry. With its distinguished editor and international team of contributors, Hybrid laser-arc welding, will be a valuable source of reference for all those using this important welding technology. Professor Flemming Ove Olsen works in the Department of Manufacturing...

  4. The ARCS radial collimator

    Directory of Open Access Journals (Sweden)

    Stone M.B.

    2015-01-01

    Full Text Available We have designed, installed, and commissioned a scattered beam radial collimator for use at the ARCS Wide Angular Range Chopper Spectrometer at the Spallation Neutron Source. The collimator has been designed to work effectively for thermal and epithermal neutrons and with a range of sample environments. Other design considerations include the accommodation of working within a high vacuum environment and having the ability to quickly install and remove the collimator from the scattered beam. We present here characterization of the collimator's performance and methodologies for its effective use.

  5. The ARCS radial collimator

    Science.gov (United States)

    Stone, M. B.; Niedziela, J. L.; Overbay, M. A.; Abernathy, D. L.

    2015-01-01

    We have designed, installed, and commissioned a scattered beam radial collimator for use at the ARCS Wide Angular Range Chopper Spectrometer at the Spallation Neutron Source. The collimator has been designed to work effectively for thermal and epithermal neutrons and with a range of sample environments. Other design considerations include the accommodation of working within a high vacuum environment and having the ability to quickly install and remove the collimator from the scattered beam. We present here characterization of the collimator's performance and methodologies for its effective use.

  6. Optical diagnostics of a gliding arc.

    Science.gov (United States)

    Sun, Z W; Zhu, J J; Li, Z S; Aldén, M; Leipold, F; Salewski, M; Kusano, Y

    2013-03-11

    Dynamic processes in a gliding arc plasma generated between two diverging electrodes in ambient air driven by 31.25 kHz AC voltage were investigated using spatially and temporally resolved optical techniques. The life cycles of the gliding arc were tracked in fast movies using a high-speed camera with framing rates of tens to hundreds of kHz, showing details of ignition, motion, pulsation, short-cutting, and extinction of the plasma column. The ignition of a new discharge occurs before the extinction of the previous discharge. The developed, moving plasma column often short-cuts its current path triggered by Townsend breakdown between the two legs of the gliding arc. The emission from the plasma column is shown to pulsate at a frequency of 62.5 kHz, i.e., twice the frequency of the AC power supply. Optical emission spectra of the plasma radiation show the presence of excited N2, NO and OH radicals generated in the plasma and the dependence of their relative intensities on both the distance relative to the electrodes and the phase of the driving AC power. Planar laser-induced fluorescence of the ground-state OH radicals shows high intensity outside the plasma column rather than in the center suggesting that ground-state OH is not formed in the plasma column but in its vicinity.

  7. Correlation methods in cutting arcs

    Energy Technology Data Exchange (ETDEWEB)

    Prevosto, L; Kelly, H, E-mail: prevosto@waycom.com.ar [Grupo de Descargas Electricas, Departamento Ing. Electromecanica, Universidad Tecnologica Nacional, Regional Venado Tuerto, Laprida 651, Venado Tuerto (2600), Santa Fe (Argentina)

    2011-05-01

    The present work applies similarity theory to the plasma emanating from transferred arc, gas-vortex stabilized plasma cutting torches, to analyze the existing correlation between the arc temperature and the physical parameters of such torches. It has been found that the enthalpy number significantly influence the temperature of the electric arc. The obtained correlation shows an average deviation of 3% from the temperature data points. Such correlation can be used, for instance, to predict changes in the peak value of the arc temperature at the nozzle exit of a geometrically similar cutting torch due to changes in its operation parameters.

  8. Capacitated arc routing problem and its extensions in waste collection

    Energy Technology Data Exchange (ETDEWEB)

    Fadzli, Mohammad; Najwa, Nurul [Institut Matematik Kejuruteraan, Universiti Malaysia Perlis, Kampus Pauh Putra, 02600 Arau, Perlis (Malaysia); Luis, Martino [Othman Yeop Abdullah Graduate School of Business, Universiti Utara Malaysia, 06010 Sintok, Kedah (Malaysia)

    2015-05-15

    Capacitated arc routing problem (CARP) is the youngest generation of graph theory that focuses on solving the edge/arc routing for optimality. Since many years, operational research devoted to CARP counterpart, known as vehicle routing problem (VRP), which does not fit to several real cases such like waste collection problem and road maintenance. In this paper, we highlighted several extensions of capacitated arc routing problem (CARP) that represents the real-life problem of vehicle operation in waste collection. By purpose, CARP is designed to find a set of routes for vehicles that satisfies all pre-setting constraints in such that all vehicles must start and end at a depot, service a set of demands on edges (or arcs) exactly once without exceeding the capacity, thus the total fleet cost is minimized. We also addressed the differentiation between CARP and VRP in waste collection. Several issues have been discussed including stochastic demands and time window problems in order to show the complexity and importance of CARP in the related industry. A mathematical model of CARP and its new version is presented by considering several factors such like delivery cost, lateness penalty and delivery time.

  9. Capacitated arc routing problem and its extensions in waste collection

    Science.gov (United States)

    Fadzli, Mohammad; Najwa, Nurul; Luis, Martino

    2015-05-01

    Capacitated arc routing problem (CARP) is the youngest generation of graph theory that focuses on solving the edge/arc routing for optimality. Since many years, operational research devoted to CARP counterpart, known as vehicle routing problem (VRP), which does not fit to several real cases such like waste collection problem and road maintenance. In this paper, we highlighted several extensions of capacitated arc routing problem (CARP) that represents the real-life problem of vehicle operation in waste collection. By purpose, CARP is designed to find a set of routes for vehicles that satisfies all pre-setting constraints in such that all vehicles must start and end at a depot, service a set of demands on edges (or arcs) exactly once without exceeding the capacity, thus the total fleet cost is minimized. We also addressed the differentiation between CARP and VRP in waste collection. Several issues have been discussed including stochastic demands and time window problems in order to show the complexity and importance of CARP in the related industry. A mathematical model of CARP and its new version is presented by considering several factors such like delivery cost, lateness penalty and delivery time.

  10. Searching standard parameters for volumetric modulated arc therapy (VMAT of prostate cancer

    Directory of Open Access Journals (Sweden)

    Treutwein Marius

    2012-07-01

    Full Text Available Abstract Background Since December 2009 a new VMAT planning system tool is available in Oncentra® MasterPlan v3.3 (Nucletron B.V.. The purpose of this study was to work out standard parameters for the optimization of prostate cancer. Methods For ten patients with localized prostate cancer plans for simultaneous integrated boost were optimized, varying systematically the number of arcs, collimator angle, the maximum delivery time, and the gantry spacing. Homogeneity in clinical target volume, minimum dose in planning target volume, median dose in the organs at risk, maximum dose in the posterior part of the rectum, and number of monitor units were evaluated using student’s test for statistical analysis. Measurements were performed with a 2D-array, taking the delivery time, and compared to the calculation by the gamma method. Results Plans with collimator 45° were superior to plans with collimator 0°. Single arc resulted in higher minimum dose in the planning target volume, but also higher dose values to the organs at risk, requiring less monitor units per fraction dose than dual arc. Single arc needs a higher value (per arc for the maximum delivery time parameter than dual arc, but as only one arc is needed, the measured delivery time was shorter and stayed below 2.5 min versus 3 to 5 min. Balancing plan quality, dosimetric results and calculation time, a gantry spacing of 4° led to optimal results. Conclusion A set of parameters has been found which can be used as standard for volumetric modulated arc therapy planning of prostate cancer.

  11. Comparison of hybrid volumetric modulated arc therapy (VMAT technique and double arc VMAT technique in the treatment of prostate cancer

    Directory of Open Access Journals (Sweden)

    Amaloo Christopher

    2015-09-01

    Full Text Available Background. Volumetric modulated arc therapy (VMAT has quickly become accepted as standard of care for the treatment of prostate cancer based on studies showing it is able to provide faster delivery with adequate target coverage and reduced monitor units while maintaining organ at risk (OAR sparing. This study aims to demonstrate the potential to increase dose conformality with increased planner control and OAR sparing using a hybrid treatment technique compared to VMAT.

  12. Alternating-Polarity Arc Welding

    Science.gov (United States)

    Schwinghamer, R. J.

    1987-01-01

    Brief reversing polarity of welding current greatly improves quality of welds. NASA technical memorandum recounts progress in art of variable-polarity plasma-arc (VPPA) welding, with emphasis on welding of aluminum-alloy tanks. VPPA welders offer important advantages over conventional single-polarity gas/tungsten arc welders.

  13. 摆位稳健性对IMRT与VMAT剂量学影响研究%Effects of positioning robustness on dosimetry for intensity-modulated radiation therapy and volumetric modulated arc therapy

    Institute of Scientific and Technical Information of China (English)

    张彪; 贾鹏飞; 汤乐民

    2016-01-01

    目的 比较摆位稳健性对头颈部肿瘤IMRT与VMAT剂量分布的影响程度,评价两者对图像引导需求.方法 纳入30例IMRT鼻咽癌患者按临床上剂量要求设计VMAT计划,AAA法计算剂量.每患者两计划分别沿原始x、y、z轴各移动等中心±1.0、±3.0、±5.0 mm模拟左右、上下、前后方向摆位误差对剂量分布影响,分析60个参考计划与1080个再计划DVH参数.配对t检验差异.结果 误差为1mm时,GTV D98、CTV D95、HI、PGTV V95平均偏差<0.5%;误差为3mm时,GTV与CTV剂量平均变化<1.0%,且VMAT高于IMRT(GTV D98,P=0.00;CTV D95,P=0.00),PGTV剂量偏差要大,IMRT与VAMT中PGTVnx与PGTVndV 95平均偏差分别为[1.64%比1.95%(P=0.01)]、[1.73%比2.63%(P=0.00)].误差增大各指标偏差变大,且VMAT高于IMRT(GTV D98,P=0.00;CTV D95,P=0.00;CTV HI,P=0.00;PGTV V95,P=0.01).相比靶区,脊髓、脑干Dmax变化更大,但1MRT与VMAT间差异不明显.结论 误差较小时(<3mm),IMRT与VMAT计划均较稳健.VMAT对摆位误差更敏感,主要体现在靶区剂量,随摆位误差增加两者间差异变大.建议行VMAT患者增加图像引导频次.%Objective To compare the effects of positioning robustness on dose distribution between intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for head and neck tumor,and to evaluate their needs for image-based guidance.Methods Thirty patients with nasopharyngeal carcinoma undergoing IMRT were enrolled as subjects.The VMAT plans were designed according to the clinical dosimetric requirements and the dose calculation was made by the AAA method.For the two plans in each patient,the isocenters were shifted by ±1.0,±3.0,and ±5.0 mm along the original x,y,and z axes to simulate the impacts of positioning errors in left-right (LR),superior-inferior (SI),and anterior-posterior (AP) directions,respectively,on dose distribution.The dose-volume histogram parameters were analyzed in 60 references and 1080

  14. Identification of GMAW dynamic process of arc welding robot based on radiation temperature measurement%基于辐射测温的弧焊机器人GMAW动态过程辨识

    Institute of Scientific and Technical Information of China (English)

    岳建锋; 李亮玉

    2007-01-01

    研究弧焊机器人GMAW(Gas Metal Arc Welding,熔化极气体弧焊)动态过程,采用比色测温仪对温度场特定点温度进行采集,采用面积法对送丝速度和测温点温度之间的模型进行了辨识.仿真结果表明,该模型准确地反映了输入输出的关系,仿真数据与实验数据的均方差仅为3%.

  15. Characteristics of Arcs Between Porous Carbon Electrodes

    OpenAIRE

    Carvou, Erwann; Le Garrec, Jean-Luc; Mitchell, Brian

    2013-01-01

    International audience; Arcs between carbon electrodes present some specific differences compared with metallic arcs. The arc voltage is higher, but does not attain a stable value displaying large fluctuations. Indeed, the arcs are produced by the direct sublimation of the electrodes, without passing through a molten phase. The arc production is also facilitated by both circuit breaking and electric field breakdown. In this paper, arcing has been examined under various conditions (voltage, cu...

  16. An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery

    Science.gov (United States)

    Davies, G. A.; Clowes, P.; Bedford, J. L.; Evans, P. M.; Webb, S.; Poludniowski, G.

    2013-07-01

    An algorithm for dynamic multileaf-collimator (dMLC) tracking of a target performing a known a priori, rigid-body motion during volumetric modulated arc therapy (VMAT), has been experimentally validated and applied to investigate the potential of the Agility (Elekta AB, Stockholm, Sweden) multileaf-collimator (MLC) for use in motion-compensated VMAT delivery. For five VMAT patients, dosimetric measurements were performed using the Delta4 radiation detector (ScandiDos, Uppsala, Sweden) and the accuracy of dMLC tracking was evaluated using a gamma-analysis, with threshold levels of 3% for dose and 3 mm for distance-to-agreement. For a motion trajectory with components in two orthogonal directions, the mean gamma-analysis pass rate without tracking was found to be 58.0%, 59.0% and 60.9% and was increased to 89.1%, 88.3% and 93.1% with MLC tracking, for time periods of motion of 4 s, 6 s and 10 s respectively. Simulations were performed to compare the efficiency of the Agility MLC with the MLCi MLC when used for motion-compensated VMAT delivery for the same treatment plans and motion trajectories. Delivery time increases from a static-tumour to dMLC-tracking VMAT delivery were observed in the range 0%-20% for the Agility, and 0%-57% with the MLCi, indicating that the increased leaf speed of the Agility MLC is beneficial for MLC tracking during lung radiotherapy.

  17. The dose delivery effect of the different Beam ON interval in FFF SBRT: TrueBEAM

    Science.gov (United States)

    Tawonwong, T.; Suriyapee, S.; Oonsiri, S.; Sanghangthum, T.; Oonsiri, P.

    2016-03-01

    The purpose of this study is to determine the dose delivery effect of the different Beam ON interval in Flattening Filter Free Stereotactic Body Radiation Therapy (FFF-SBRT). The three 10MV-FFF SBRT plans (2 half rotating Rapid Arc, 9 to10 Gray/Fraction) were selected and irradiated in three different intervals (100%, 50% and 25%) using the RPM gating system. The plan verification was performed by the ArcCHECK for gamma analysis and the ionization chamber for point dose measurement. The dose delivery time of each interval were observed. For gamma analysis (2%&2mm criteria), the average percent pass of all plans for 100%, 50% and 25% intervals were 86.1±3.3%, 86.0±3.0% and 86.1±3.3%, respectively. For point dose measurement, the average ratios of each interval to the treatment planning were 1.012±0.015, 1.011±0.014 and 1.011±0.013 for 100%, 50% and 25% interval, respectively. The average dose delivery time was increasing from 74.3±5.0 second for 100% interval to 154.3±12.6 and 347.9±20.3 second for 50% and 25% interval, respectively. The same quality of the dose delivery from different Beam ON intervals in FFF-SBRT by TrueBEAM was illustrated. While the 100% interval represents the breath-hold treatment technique, the differences for the free-breathing using RPM gating system can be treated confidently.

  18. Arc Interference Behavior during Twin Wire Gas Metal Arc Welding Process

    Directory of Open Access Journals (Sweden)

    Dingjian Ye

    2013-01-01

    Full Text Available In order to study arc interference behavior during twin wire gas metal arc welding process, the synchronous acquisition system has been established to acquire instantaneous information of arc profile including dynamic arc length variation as well as relative voltage and current signals. The results show that after trailing arc (T-arc is added to the middle arc (M-arc in a stable welding process, the current of M arc remains unchanged while the agitation increases; the voltage of M arc has an obvious increase; the shape of M arc changes, with increasing width, length, and area; the transfer frequency of M arc droplet increases and the droplet itself becomes smaller. The wire extension length of twin arc turns out to be shorter than that of single arc welding.

  19. Controllability of arc jet from arc horns with slits. Slit tsuki arc horn no arc jet seigyo tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Sunabe, K.; Inaba, T.; Fukagawa, H. (Central Research Institute of Electric Power Industry, Tokyo (Japan)); Kito, Y. (Nagoya University, Nagoya (Japan))

    1993-09-20

    To improve the corona discharge characteristics, test preparation was made of hollow rod form horns with slits for the overhead power transmission line use. Two types of horn electrode were prepared. The first horn electrode is of a hollow hemisphere fitted with and divided by slits on its tip. The second horn electrode is the first one which is further fitted with rod form electrode at the center of its tip. In experiment, relation was obtained between the deflection angle of arc jet and arc current, electrode diameter, etc., through an observation of arc jet by high speed camera. Melting loss of electrode was also made clear. The following knowledge was obtained: For the first horn electrode, the deflection angle can be limited to a narrow range by a division with slits, e.g., within 30 degrees under the condition of 5kA in arc current, 4 in number of sectors and 200mm in diameter. For the second horn electrode, the deflection angle can be limited to within 20 degrees under the condition of 5kA in arc current and 4 in number of sectors. The arc current is also limited to below 5kA by an addition of 50mm diameter central electrode. As a conclusion for the first electrode, the arc jet control characteristics excels in the stronger arc current range than 5kA, while for the second electrode, they are effective in the weaker arc current range than 5kA. 6 refs., 19 figs., 1 tab.

  20. Arc spot grouping: An entanglement of arc spot cells

    Energy Technology Data Exchange (ETDEWEB)

    Kajita, Shin, E-mail: kajita.shin@nagoya-u.jp [EcoTopia Science Institute, Nagoya University, Nagoya 464-8603 (Japan); Hwangbo, Dogyun; Ohno, Noriyasu [Graduate School of Engineering, Nagoya University, Nagoya 464-8603 (Japan); Tsventoukh, Mikhail M. [Lebedev Physical Institute, Russian Academy of Sciences, Moscow 119991 (Russian Federation); Barengolts, Sergey A. [Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow 119991 (Russian Federation)

    2014-12-21

    In recent experiments, clear transitions in velocity and trail width of an arc spot initiated on nanostructured tungsten were observed on the boundary of the thick and thin nanostructured layer regions. The velocity of arc spot was significantly decreased on the thick nanostructured region. It was suggested that the grouping decreased the velocity of arc spot. In this study, we try to explain the phenomena using a simple random walk model that has properties of directionality and self-avoidance. And grouping feature was added by installing an attractive force between spot cells with dealing with multi-spots. It was revealed that an entanglement of arc spot cells decreased the spot velocity, and spot cells tend to stamp at the same location many times.

  1. Flexible delivery of Er:YAG radiation at 2.94 µm with negative curvature silica glass fibers: a new solution for minimally invasive surgical procedures.

    Science.gov (United States)

    Urich, A; Maier, R R J; Yu, Fei; Knight, J C; Hand, D P; Shephard, J D

    2013-02-01

    We present the delivery of high energy microsecond pulses through a hollow-core negative-curvature fiber at 2.94 µm. The energy densities delivered far exceed those required for biological tissue manipulation and are of the order of 2300 J/cm(2). Tissue ablation was demonstrated on hard and soft tissue in dry and aqueous conditions with no detrimental effects to the fiber or catastrophic damage to the end facets. The energy is guided in a well confined single mode allowing for a small and controllable focused spot delivered flexibly to the point of operation. Hence, a mechanically and chemically robust alternative to the existing Er:YAG delivery systems is proposed which paves the way for new routes for minimally invasive surgical laser procedures.

  2. Convergent evolution of the arginine deiminase pathway: the ArcD and ArcE arginine/ornithine exchangers.

    Science.gov (United States)

    Noens, Elke E E; Lolkema, Juke S

    2017-02-01

    The arginine deiminase (ADI) pathway converts L-arginine into L-ornithine and yields 1 mol of ATP per mol of L-arginine consumed. The L-arginine/L-ornithine exchanger in the pathway takes up L-arginine and excretes L-ornithine from the cytoplasm. Analysis of the genomes of 1281 bacterial species revealed the presence of 124 arc gene clusters encoding the pathway. About half of the clusters contained the gene encoding the well-studied L-arginine/L-ornithine exchanger ArcD, while the other half contained a gene, termed here arcE, encoding a membrane protein that is not a homolog of ArcD. The arcE gene product of Streptococcus pneumoniae was shown to take up L-arginine and L-ornithine with affinities of 0.6 and 1 μmol/L, respectively, and to catalyze metabolic energy-independent, electroneutral exchange. ArcE of S. pneumoniae could replace ArcD in the ADI pathway of Lactococcus lactis and provided the cells with a growth advantage. In contrast to ArcD, ArcE catalyzed translocation of the pathway intermediate L-citrulline with high efficiency. A short version of the ADI pathway is proposed for L-citrulline catabolism and the presence of the evolutionary unrelated arcD and arcE genes in different organisms is discussed in the context of the evolution of the ADI pathway.

  3. Investigation on the arc light spectrum in GTA welding

    Directory of Open Access Journals (Sweden)

    M.S. Węglowski

    2007-01-01

    Full Text Available Purpose: In the paper there are presented results of the influence of welding parameters on spectral intensity ofthe welding arc in the range of 340÷860 nm. The main goal was checking whether the visible radiation of thearc provides information which might prove to be useful in monitoring of the welding process, similarly as thesignals recorded in the electric circuit of the welding arc.Design/methodology/approach: The experimental station was designed and build. A spectrophotometer, in thevisible spectral range of 340 nm to 860 nm, was used. The investigations were conducted on the automated GTAwelding station. For each welding parameter the arc light spectrum was measuredFindings: Research results presented in this paper indicate that the welding arc radiation contains a number ofinformation concerning the course of the welding process. That signal is much more sensitive to the changes ofwelding conditions and should be used as a tool for monitoring of the TIG welding processResearch limitations/implications: The fiber spectrophotometer in the visible spectral range of 340 nm to860 nm is an expensive instrument and that fore it can be used only as a complementary tool in monitoring ofwelding processes.Practical implications: The gained experience allows directing farther research on the welding arc radiationphenomenon and the possibilities of using this signal for on-line monitoring of the welding process onautomated and robotized stands.This sensing system will be particularly attractive for welded structures manufacturing industry because it couldsignificantly reduce the cost for post weld analysis and repairsOriginality/value: Three fitting functions: Lorentz, Gauss and Voight were investigated as a means to simulatethe spectrum distribution. The mathematical-physical model of the arc light emission and neural networkswere compared

  4. On arc efficiency in gas tungsten arc welding

    Directory of Open Access Journals (Sweden)

    Nils Stenbacka

    2013-12-01

    Full Text Available The aim of this study was to review the literature on published arc efficiency values for GTAW and, if possible, propose a narrower band. Articles between the years 1955 - 2011 have been found. Published arc efficiency values for GTAW DCEN show to lie on a wide range, between 0.36 to 0.90. Only a few studies covered DCEP - direct current electrode positive and AC current. Specific information about the reproducibility in calorimetric studies as well as in modeling and simulation studies (considering that both random and systematic errors are small was scarce. An estimate of the average arc efficiency value for GTAW DCEN indicates that it should be about 0.77. It indicates anyway that the GTAW process with DCEN is an efficient welding method. The arc efficiency is reduced when the arc length is increased. On the other hand, there are conflicting results in the literature as to the influence of arc current and travel speed.

  5. Arc of opportunity.

    Science.gov (United States)

    Delaney, Adam Vai

    2011-07-01

    Born in Port Moresby, Papua New Guinea, the author had a 20 year career in diplomacy, political affairs, and development policy analysis at the Pacific Islands Forum, the United Nations in New York; the Prime Minister's Department in Papua New Guinea (PNG) and in the Foreign Ministry of PNG. He has also been involved in theatre for over a decade in PNG, and participated in a three-month program at the Eugene O'Neill Theatre Center in Connecticut, USA. He is currently the Business Development Manager at the Torres Strait Regional Authority (Commonwealth) on Thursday Island. Since 1975 the Australian government's overseas development policy has supported various sectoral programs in its neighbouring countries, in particular Papua New Guinea and the Solomon Islands. The "creative" field has not been prominent in this strategy. While natural resources and the sports sectors have gained much greater attention, in terms of being viable international commercial enterprises, the arts, have remained stagnant. In this paper the need for joint programs genuinely supporting "wellbeing" and promoting social enterprise throughout the "arc of opportunity" is described to harness Melanesian creativity to compete successfully in world-markets, starting with penetration of the largest economy at its door-step: Australia.

  6. Dust in the arcs of Methone and Anthe

    Science.gov (United States)

    Sun, Kai-Lung; Seiß, Martin; Hedman, M. M.; Spahn, Frank

    2017-03-01

    Methone and Anthe are two tiny moons (with diameter value in simulations is about an order of magnitude smaller. Plausible explanations for the difference include millimeter-sized particles as additional source and the uncertainties of impactor flux Fimp and the yields Y. The longitudinal extension of the Methone/Anthe arc in our simulation is 10.8°/15°, consistent with observations and theory (Hedman et al., 2009). Our results also show the lifetime distributions of particles and the heliotropic behavior of dust introduced by solar radiation pressure (Hedman et al., 2010a). The lifetimes of arc particles, defined by the time particles stay in the semi-major axes close to the source moons, are also related to particle size. Smaller ones (< 5 μm) do not stay in the arc and instead migrate outward under the influence of plasma drag. Larger grains can stay in arc in the timescale of 100 years until they leave the arcs or collide with the source moons.

  7. Water-vortex stabilized electric arc: I. Numerical model

    Science.gov (United States)

    Jenista, Jirí

    1999-11-01

    A numerical model for an electric arc stabilized by a water vortex has been proposed. The two-dimensional axisymmetric model includes the discharge area between the cathode and the orifice of the arc chamber. The production of water plasma, i.e. the rate of evaporation of a water wall, is taken either from experiments or is determined numerically by fitting of the outlet plasma parameters to the experimental ones. The computer results concern thermal, fluid dynamic and electrical characteristics of such arcs for the currents 300, 400, 500 and 600 A. It is found, for example, that the role of thermal diffusion within the discharge increases with current. The power losses from the arc due to radial conduction and radiation represent around 50% of the input power. Rotation of the plasma column due to the induced tangential velocity component has negligible effect on the overall arc performance. The calculated velocities, pressure drops and electrical potentials are in good agreement with experiments carried out on the water plasma torch PAL-160 operating at our Institute.

  8. STUDY ON THE PRESSURE IN PLASMA ARC

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The axial pressure in plasma arc is measured under different conditions. The effects of the parameters, such as welding current, plasma gas flow rate, electrode setback and arc length, on the pressure in plasma arc are investigated and quantitative analyzed to explain the relationship between the quality of weld and the matching of parameters in plasma arc welding process.

  9. SU-E-T-262: Development of An In-House Forward Planning System for Conformal Arc Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Eldib, A [Fox Chase Cancer Center, Philadelphia, PA (United States); Department of Physics, AlAzhar University, Cairo (Egypt); Chibani, O; Jin, L; Li, J; Chen, L; Lin, T; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Lin, M [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: Conformal radiotherapy with forward planning has many practical advantages (e.g., more uniform target dose) and has been used routinely for stereotactic body radiation therapy (SBRT) and other conventional treatment. This study investigates a forward-planning approach for conformal arc therapy and a dedicated treatment planning system (TPS) for a newly designed cobalt 60 machine with a ring type gantry and a multileaf collimator (MLC). Methods: Conformal arcs were modeled with continuous delivery of treatment fields conformal to the target cross-section. Treatment plans were further optimized by weighting or offsetting beams based on the target-critical structure relationship. CT and structure data of seven previous SBRT patients treated at our center were used for plan evaluation. An in-house forward planning tool was developed to aid the forward planning process. A graphical user interface (GUI) was designed with interactive and automatic adjustment between beam gantry angle and the beam weight. Dose distributions were calculated using our in-house Monte Carlo based TPS. Dose contributions from individual beam angles were summed together with different weight factors, which were continuously optimized until the pre-set dose conformity goal was met. Results: We were able to achieve target coverage and critical structure sparing to meet the required clinical criteria in all studied cases. It should be mentioned that those cases were selected having critical structures not proximal to the target. However, this was usually the case in the majority of SBRT cases especially those involving lung targets. The developed GUI tool was very useful in the forward treatment planning process. Conclusion: Conformal arcs can be used successfully on the new Cobalt 60 modality for the treatment of a sizeable fraction of cancer patients, which can be efficiently planned with our simple forward planning approach.

  10. [Arc spectrum diagnostic and heat coupling mechanism analysis of double wire pulsed MIG welding].

    Science.gov (United States)

    Liu, Yong-qiang; Li, Huan; Yang, Li-jun; Zheng, Kai; Gao, Ying

    2015-01-01

    A double wire pulsed MIG welding test system was built in the present paper, in order to analyze the heat-coupling mechanism of double wire pulsed MIG welding, and study are temperature field. Spectroscopic technique was used in diagnostic analysis of the are, plasma radiation was collected by using hollow probe method to obtain the arc plasma optical signal The electron temperature of double wire pulsed MIG welding arc plasma was calculated by using Boltzmann diagram method, the electron temperature distribution was obtained, a comprehensive analysis of the arc was conducted combined with the high speed camera technology and acquisition means of electricity signal. The innovation of this paper is the combination of high-speed camera image information of are and optical signal of arc plasma to analyze the coupling mechanism for dual arc, and a more intuitive analysis for are temperature field was conducted. The test results showed that a push-pull output was achieved and droplet transfer mode was a drop in a pulse in the welding process; Two arcs attracted each other under the action of a magnetic field, and shifted to the center of the arc in welding process, so a new heat center was formed at the geometric center of the double arc, and flowing up phenomenon occurred on the arc; Dual arc electronic temperature showed an inverted V-shaped distribution overall, and at the geometric center of the double arc, the arc electron temperature at 3 mm off the workpiece surface was the highest, which was 16,887.66 K, about 4,900 K higher than the lowest temperature 11,963.63 K.

  11. Drug delivery system prepared by ionizing radiation of the N,N-dimethyl acrylamide with acryloyloxy-acetanilide copolymerization; Sistema de liberacao de droga obtido via radiacao ionizante pela copolimerizacao do N,N-dimetilacrilamida com 4-acriloiloxiacetanilida

    Energy Technology Data Exchange (ETDEWEB)

    Martellini, Flavia; Higa, Olga Z. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Queiroz, Alvaro A.A. de [Escola Federal de Engenharia de Itajuba, MG (Brazil); Rodighiero, Paolo [Universidade de Padova (Italy). Inst. de Ciencias Farmaceuticas

    1995-12-31

    Radiation induced polymerization has been used in biomaterials used in systems which such as drug delivery (DDS). This work describes the copolymerization of the monomers by gamma rays N,N-dimethyl acrylamide (DMAA) and acryloyloxy-acetanilide (AOA) for the immobilization of paracetamol, an analgesic and anti thermic drug. Dimethylformamide solutions were used in two concentrations of DMAA and AOA (F{sub DMAA/AOA} = 0,85/015 and 0,70/0,30, where F = molar fraction in the monomer feed). The samples were irradiated in the dose range of 30-800 Gy. The copolymer poly(DMAA-co-AOA) characterization was carried out by FTIR and {sup 1}HRMN. The hydrolysis was studied considering the formation of sodium salts of 4-hydroxy acetanilide at different times of treatment using colorimetric assay. (author). 6 refs., 5 figs.

  12. Stereotactic body radiation therapy for liver metastasis-Case report and review of the literature. The role of patient preparation, treatment planning and its delivery

    Directory of Open Access Journals (Sweden)

    Marta Adamczyk

    2014-01-01

    Results: The conventional 3-dimensional conformal plan, which fulfilled all dose constraints for target and organs at risk, was accepted for the treatment. Almost for all performed patient position verifications, on-line evaluated results were kept under 5 mm. Conclusions: The analysis presents the possible way of treating patients with liver metastasis. The SBRT treatment prepared and verified according our protocol can be implemented in clinical practice for a vast majority of such patients. The literature validation of our liver SBRT protocol showed that it has the potential for ensuring the effective and patient-friendly delivery.

  13. Fabrication of graphene from graphite by a thermal assisted vacuum arc discharge system

    Science.gov (United States)

    Cheng, Guo-Wei; Chu, Kevin; Chen, Jeng Shiung; Tsai, Jeff T. H.

    2017-04-01

    In this study, graphene was fabricated on copper foils using a high temperature furnace embedded in a vacuum arc discharge method. Combining the advantages of chemical vapor deposition and vacuum arc discharge, single-layer graphene can be fabricated at 600 °C base temperature from the mini furnace embedded with a fast heating via the photon radiation from the vacuum arc to 1100 °C on the substrates' surface. The optimal fabrication condition was determined through a series of experiments on ambient pressure, processing time, arc currents, and the cooling process. Observations by scanning electron microscopy, Raman spectroscopy, and optical microscopy showed that the main products were single-layer graphene, which has a uniform thickness across the entire substrate. The results demonstrated that the combination of a vacuum arc with a thermal method that uses graphite as a carbon source provides a low-cost and straight forward method to synthesize graphene films for graphene-based applications.

  14. A comparison of measurement techniques for quality assurance of RapidArc treatment plans

    Science.gov (United States)

    Konieczny, Jeff

    A new form of intensity modulated radiation therapy (IMRT) using the Varian RapidArc® treatment system has the potential to improve cancer treatments by delivering comparable dose distributions as TomoTherapy ®1 at a rate that is 5 to 15 times faster 2. The goal of this thesis was to compare the sensitivity of an electronic portal imaging device (EPID), film, and the ArcCheck™ device as tools for evaluation of IMRT treatments. To accomplish this, we introduced systematic errors in MLC leaf position and perform theoretical and experimental evaluations. The comparisons were made by analyzing changes in the gamma function as systematic MLC gap errors were introduced into the patient treatment plan. To study this, dynamic prostate Rapidarc™ plans were developed in Eclipse™ using the RANDO anthropomorphic phantom. After the plans were developed, the files were exported in DICOM-RT (Digital Imaging and Communications in Medicine — Radiation Therapy) format, and a program was written to modify the MLC leaf position. The files were imported back into Eclipse and recalculated using simulated film, EPID, and ArcCheck phantoms. Before measuring the plans with the devices, each instrument was calibrated and repeatability tests were performed to determine the variation in a single plan. After the delivery of the same plan eight times, film was found to have the largest variation in average gamma of 0.31 ± 0.13. When the setup was not moved in between measurements, the ArcCheck and EPID had significantly smaller variations in average gamma of 0.10 ± 0.04 and 0.07 ± 0.03 respectively. When the setup was moved and realigned in between measurements, the average gamma variation was found to be 0.22 ± 0.10 and 0.11 ± 0.05 for the ArcCheck and EPID. As a result of the higher variation, it was decided that testing should be performed without moving the detector during the course of the measurements. Film, unfortunately, had to be changed in between tests, which resulted

  15. Laser guided and stabilized gas metal arc welding processes (LGS-GMA)

    Science.gov (United States)

    Hermsdorf, Jörg; Barroi, Alexander; Kaierle, Stefan; Overmeyer, Ludger

    2013-05-01

    The demands of the industry are cheap and fast production of highly sophisticated parts without compromises in product quality. To realize this requirement, we have developed a laser guided and stabilized gas metal arc process (LGS-GMA welding). The new welding process is based on a gas metal arc process using low power laser radiation for stabilization. The laser stabilization of gas metal arcs welding is applied to joint welding and cladding. With only 400 W laser power and a focal spot of 1.6 mm the laser radiation is mainly interacting with the arc plasma in order to guide and stabilize it. In joint welding up to 100% increase in welding speed is possible, at equal penetration depth. The guidance effect also enables the process to weld in challenging situations like different sheet thicknesses. Used for cladding, the enhanced process stability allows low penetration depth with dilutions of only 3%. Coatings with up to 63 HRC were achieved.

  16. Computational Model Of Fiber Optic, Arc Fusion Splicing; Experimental Comparison

    Science.gov (United States)

    Ruffin, Paul; Frost, Walter; Long, Wayne

    1989-02-01

    Acknowledgement: The assistance and support of the MICOM Army Missile Command is gratefully appreciated. An analytical tool to investigate the arc fusion splicing of optical fibers is developed. The physical model incorporates heat transfer and thermal, visco elastic strain. The heat transfer equations governing radiation, conduction and convection during arc heating are formulated. The radiation heat flux impinging on the fiber optics is modeled based on reported experimental analysis of a generic type arc discharge. The fusion process considers deformation of the fiber due to thermal, viscous and elastic strain. A Maxwell stress-strain relationship is assumed. The model assumes an initial gap at the beginning of the arc which is closed by a press-stroke during the heating cycle. All physical properties of the fused silica glass fibers are considered as functions of temperature based on available experimental data. A computer algorithm has been developed to solve the system of governing equations and parametric studies carried out. An experiment using a FSM-20 arc fusion splicer manufactured by Fujikura Ltd. was carried out to provide experimental verification of the analytical model. In the experiment a continuous fiber was positioned in the arc and cyclic heating and cooling was carried out. One end of the fiber was clamped and the other was free to move. The fiber was heated for 6 seconds and cooled for 3 minutes for several cycles. At the end of each cooling process, photographs of the deformation of the fiber were taken. The results showed that the fiber necked down on the free end and buldged up on the fixed end. With repeated heating and cooling cycles, the optical fiber eventually necked down to the point that it melted in two. The analytical model was run for the conditions of the experiment. Comparisons of the predicted deformation of the optical fiber with those measured is given. The analytical model displays all of the physical phenomenon of fiber

  17. Single arc volumetric-modulated arc therapy is sufficient for nasopharyngeal carcinoma: a dosimetric comparison with dual arc VMAT and dynamic MLC and step-and-shoot intensity-modulated radiotherapy

    OpenAIRE

    NING, ZHONG-HUA; Mu, Jin-Ming; Jin, Jian-Xue; Li, Xiao-Dong; LI, QI-LIN; GU, WEN-DONG; Huang, Jin; Han, Yang; PEI, HONG-LEI

    2013-01-01

    Background The performance of single arc VMAT (VMAT1) for nasopharyngeal carcinoma (NPC) on the Axesse linac has not been well described in previous studies. The purpose of this study is to assess the feasibility of VMAT1 for NPC by comparing the dosimetry, delivery efficiency, and accuracy with dual arc VMAT (VMAT2), dynamic MLC intensity-modulated radiotherapy (dIMRT), and step-and-shoot intensity-modulated radiotherapy (ssIMRT). Methods Twenty consecutive patients with non-metastatic NPC w...

  18. The Time-Dependent Multiple-Vehicle Prize-Collecting Arc Routing Problem

    DEFF Research Database (Denmark)

    Black, Daniel; Eglese, Richard; Wøhlk, Sanne

    2015-01-01

    In this paper, we introduce a multi vehicle version of the Time-Dependent Prize-Collecting Arc Routing Problem (TD-MPARP). It is inspired by a situation where a transport manager has to choose between a number of full truck load pick-ups and deliveries to be performed by a fleet of vehicles. Real...

  19. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Science.gov (United States)

    Salter, Bill J.; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-01

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min-1) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  20. Dosimetric comparison between volumetric modulated arc therapy and fixed-gantry dynamic intensity modulated radiation therapy for rectal cancer radiotherapy%直肠癌旋转容积调强与固定野动态调强的剂量学比较

    Institute of Scientific and Technical Information of China (English)

    花威; 李军; 谭飞; 陈婷婷; 汪步海

    2012-01-01

    目的:比较旋转容积调强(VMAT)与固定野动态调强(dIMRT)在直肠癌放疗计划中的剂量学差异.方法:8例直肠癌患者利用瓦里安计划系统(Eclipse 8.6)分别进行VMAT和dIMRT放射治疗计划设计.利用剂量体积直方图来比较两种计划中靶区和危及器官的剂量学差异.结果:与dIMRT相比,VMAT靶区适合度指数(CI)、靶区剂量均匀性指数(HI)均更接近1,Dmin为(43.403±0.486)Gy,更接近处方剂量,差异有统计学意义,P<0.05.在VMAT计划中小肠的D30%、D50%和Dmean分别为(25.918±1.216)、(22.340士3.784)和(23.547±2.863) Gy,低于dIMRT计划的(28.073±3.114)、(24.172±2.540)和(25.257±1.374) Gy,P值分别为0.00、0.01和0.00;膀胱的D30%为(35.380±2.734) Gy,较dIMRT的(30.123±2.209) Gy偏高,P=0.00,但仍远低于剂量限值;股骨头的D5%和Dmean分别为(31.344±3.556)和(20.179±3.017) Gy,显著高于dIMRT计划的(26.731±2.828)和(17.459±3.279) Gy,P值均为0.00.VMAT总MU减少52.7%,治疗时间仅为dIMRT的1/4.结论:VMAT计划可以达到或优于dIMRT计划的靶区剂量分布,能更好地降低部分危及器官的受照剂量,并且具有较少总MU、总治疗时间的优势,减少了治疗中不确定性因素的影响及患者不适感.%OBJECTIVE: To compare the dosimetric difference between volumetric modulated arc therapy(VMAT) and fixed-gantry dynamic intensity modulated radiation therapy(dIMRT) for rectal cancer. METHODS: VMAT and dlM-RT treatment plans of 8 rectal cancer cases were generated by Vrian Eclipse ver8. 6 treatment planning systerm. Dose volume histograms were used to compare the target volume and organs at risks. RESULTS: Compared to dIMRT,conformity index(CI) and homogeneity index(HI) of VMAT closer to one. Dmin of VMAT was (43. 403 ± 0. 486) Gy,closer to prescription dose. There were significant differences in CI,HI and Dmin(P<0. 05). The small intestinal's D30% ,D50% and Dmean were larger in dIMRT than those in VAMT(P values were

  1. Water-vortex stabilized electric arc: II. Effect of non-uniform evaporation of water

    Science.gov (United States)

    Jenista, Jirí

    1999-11-01

    The paper deals with a numerical model of an electric arc stabilized by a water vortex. The axisymmetric model involves the area between the cathode and the output nozzle of the arc. The rate of evaporation of water (production of water plasma) is determined from radial conduction and radiation heat fluxes near the water-water-vapour phase transition. The influence of non-uniform evaporation rate along the discharge coordinate on the outlet arc parameters is studied for the currents 300 and 600 A. It is found from calculations that part of the power spent on evaporation is in the range 1.4-3.1% of the total input power. The dominant source of power losses from the arc is plasma radiation, which exceeds conduction losses by a factor of two to four. Since the majority of the arc discharge is nearly thermally fully-developed, the effect of non-uniformity of evaporation on the overall arc performance is minor. The calculated arc outlet characteristics are in good agreement with our data published previously, as well as with experiments carried out on the water plasma torch operating at our Institute.

  2. High pressure neon arc lamp

    Science.gov (United States)

    Sze, Robert C.; Bigio, Irving J.

    2003-07-15

    A high pressure neon arc lamp and method of using the same for photodynamic therapies is provided. The high pressure neon arc lamp includes a housing that encloses a quantity of neon gas pressurized to about 500 Torr to about 22,000 Torr. At each end of the housing the lamp is connected by electrodes and wires to a pulse generator. The pulse generator generates an initial pulse voltage to breakdown the impedance of the neon gas. Then the pulse generator delivers a current through the neon gas to create an electrical arc that emits light having wavelengths from about 620 nanometers to about 645 nanometers. A method for activating a photosensitizer is provided. Initially, a photosensitizer is administered to a patient and allowed time to be absorbed into target cells. Then the high pressure neon arc lamp is used to illuminate the target cells with red light having wavelengths from about 620 nanometers to about 645 nanometers. The red light activates the photosensitizers to start a chain reaction that may involve oxygen free radicals to destroy the target cells. In this manner, a high pressure neon arc lamp that is inexpensive and efficiently generates red light useful in photodynamic therapy is provided.

  3. SU-E-T-789: Validation of 3DVH Accuracy On Quantifying Delivery Errors Based On Clinical Relevant DVH Metrics

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T; Kumaraswamy, L [Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Detection of treatment delivery errors is important in radiation therapy. However, accurate quantification of delivery errors is also of great importance. This study aims to evaluate the 3DVH software’s ability to accurately quantify delivery errors. Methods: Three VMAT plans (prostate, H&N and brain) were randomly chosen for this study. First, we evaluated whether delivery errors could be detected by gamma evaluation. Conventional per-beam IMRT QA was performed with the ArcCHECK diode detector for the original plans and for the following modified plans: (1) induced dose difference error up to ±4.0% and (2) control point (CP) deletion (3 to 10 CPs were deleted) (3) gantry angle shift error (3 degree uniformly shift). 2D and 3D gamma evaluation were performed for all plans through SNC Patient and 3DVH, respectively. Subsequently, we investigated the accuracy of 3DVH analysis for all cases. This part evaluated, using the Eclipse TPS plans as standard, whether 3DVH accurately can model the changes in clinically relevant metrics caused by the delivery errors. Results: 2D evaluation seemed to be more sensitive to delivery errors. The average differences between ECLIPSE predicted and 3DVH results for each pair of specific DVH constraints were within 2% for all three types of error-induced treatment plans, illustrating the fact that 3DVH is fairly accurate in quantifying the delivery errors. Another interesting observation was that even though the gamma pass rates for the error plans are high, the DVHs showed significant differences between original plan and error-induced plans in both Eclipse and 3DVH analysis. Conclusion: The 3DVH software is shown to accurately quantify the error in delivered dose based on clinically relevant DVH metrics, where a conventional gamma based pre-treatment QA might not necessarily detect.

  4. Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device

    Directory of Open Access Journals (Sweden)

    Rowshanfarzad P

    2015-11-01

    Full Text Available Pejman Rowshanfarzad,1 Peter Häring,2 Hans L Riis,3 Sune J Zimmermann,3 Martin A Ebert1,4 1School of Physics, The University of Western Australia, Crawley, WA, Australia; 2German Cancer Research Center (DKFZ, Medical Physics in Radiation Oncology, Heidelberg, Germany; 3Radiofysisk Laboratorium, Odense University Hospital, Odense C, Denmark; 4Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia Background: In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evaluating machine-related errors in treatments. Methods: The EPID sag, gantry sag, changes in source-to-detector distance (SDD, EPID and collimator skewness, EPID tilt, and the sag in leaf bank assembly due to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with five ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of image data. Three Siemens linacs were investigated. Results: The average EPID sag was within 1 mm for all tested linacs. Two machines showed >1 mm gantry sag. Changes in the SDD values were within 7.5 mm. EPID skewness and tilt values were <1° in all machines. The maximum sag in leaf bank assembly was <1 mm. Conclusion: The method and software developed in this study provide a simple tool for effective investigation of the behavior of Siemens linac components with gantry rotation. Such a comprehensive study has been performed for the first time on Siemens machines. Keywords: linac, Siemens, arc, sag, EPID, gantry

  5. Is high–dose rate RapidArc-based radiosurgery dosimetrically advantageous for the treatment of intracranial tumors?

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Bo; Yang, Yong, E-mail: yangy2@upmc.edu; Li, Xiang; Li, Tianfang; Heron, Dwight E.; Saiful Huq, M.

    2015-04-01

    In linac-based stereotactic radiosurgery (SRS) and radiotherapy (SRT), circular cone(s) or conformal arc(s) are conventionally used to treat intracranial lesions. However, when the target is in close proximity to critical structures, it is frequently quite challenging to generate a quality plan using these techniques. In this study, we investigated the dosimetric characteristics of using high–dose rate RapidArc (RA) technique for radiosurgical treatment of intracranial lesions. A total of 10 intracranial SRS/SRT cases previously planned using dynamic conformal arc (DCA) or cone-based techniques have been included in this study. For each case, 3 treatment plans were generated: (1) a DCA plan with multiple noncoplanar arcs, (2) a high–dose rate RA plan with arcs oriented the same as DCA (multiple-arc RA), and 3) a high–dose rate RA plan with a single coplanar arc (single-arc RA). All treatment plans were generated under the same prescription and similar critical structure dose limits. Plan quality for different plans was evaluated by comparing various dosimetric parameters such as target coverage, conformity index (CI), homogeneity index (HI), critical structures, and normal brain tissue doses as well as beam delivery time. With similar critical structure sparing, high–dose rate RA plans can achieve much better target coverage, dose conformity, and dose homogeneity than the DCA plans can. Plan quality indices CI and HI, for the DCA, multiple-arc RA, and single-arc RA techniques, were measured as 1.67 ± 0.39, 1.32 ± 0.28, and 1.38 ± 0.30 and 1.24 ± 0.11, 1.10 ± 0.04, and 1.12 ± 0.07, respectively. Normal brain tissue dose (V{sub 12} {sub Gy}) was found to be similar for DCA and multiple-arc RA plans but much larger for the single-arc RA plans. Beam delivery was similar for DCA and multiple-arc RA plans but shorter with single-arc RA plans. Multiple-arc RA SRS/SRT can provide better treatment plans than conventional DCA plans, especially for complex cases.

  6. Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

    Institute of Scientific and Technical Information of China (English)

    Suresh Rana; ChihYao Cheng

    2013-01-01

    The volumetric modulated arc therapy (VMAT) technique, in the form of RapidArc, is widely used to treat prostate cancer. The full-single arc (f-SA) technique in RapidArc planning for prostate cancer treatment provides efficient treatment, but it also delivers a higher radiation dose to the rectum. This study aimed to compare the dosimetric results from the new partial-single arc (p-SA) technique with those from the f-SA technique in RapidArc planning for prostate cancer treatment. In this study, 10 patients with low-risk prostate cancer were selected. For each patient, two sets of RapidArc plans (f-SA and p-SA) were created in the Eclipse treatment planning system. The f-SA plan was created using one ful arc, and the p-SA plan was created using planning parameters identical to those of the f-SA plan but with anterior and posterior avoidance sectors. Various dosimetric parameters of the f-SA and p-SA plans were evaluated and compared for the same target coverage and identical plan optimization parameters. The f-SA and p-SA plans showed an average difference of ±1% for the doses to the planning target volume (PTV), and there were no clear differences in dose homogeneity or plan conformity. In comparison to the f-SA technique, the p-SA technique reduced the doses to the rectum by approximately 6.1% to 21.2%, to the bladder by approximately 10.3%to 29.5%, and to the penile bulb by approximately 2.2%. In contrast, the dose to the femoral heads, the integral dose, and the number of monitor units were higher in the p-SA plans by approximately 34.4%, 7.7%, and 9.2%, respectively. In conclusion, it is feasible to use the p-SA technique for RapidArc planning for prostate cancer treatment. For the same PTV coverage and identical plan optimization parameters, the p-SA technique is better in sparing the rectum and bladder without compromising plan conformity or target homogeneity when compared to the f-SA technique.

  7. Variable dose rate single-arc IMAT delivered with a constant dose rate and variable angular spacing.

    Science.gov (United States)

    Tang, Grace; Earl, Matthew A; Yu, Cedric X

    2009-11-07

    Single-arc intensity-modulated arc therapy (IMAT) has gained worldwide interest in both research and clinical implementation due to its superior plan quality and delivery efficiency. Single-arc IMAT techniques such as the Varian RapidArc deliver conformal dose distributions to the target in one single gantry rotation, resulting in a delivery time in the order of 2 min. The segments in these techniques are evenly distributed within an arc and are allowed to have different monitor unit (MU) weightings. Therefore, a variable dose-rate (VDR) is required for delivery. Because the VDR requirement complicates the control hardware and software of the linear accelerators (linacs) and prevents most existing linacs from delivering IMAT, we propose an alternative planning approach for IMAT using constant dose-rate (CDR) delivery with variable angular spacing. We prove the equivalence by converting VDR-optimized RapidArc plans to CDR plans, where the evenly spaced beams in the VDR plan are redistributed to uneven spacing such that the segments with larger MU weighting occupy a greater angular interval. To minimize perturbation in the optimized dose distribution, the angular deviation of the segments was restricted to single gantry sweep as in the VDR plans but each sector was delivered with a different value of CDR. For four patient cases, including two head-and-neck, one brain and one prostate, all CDR plans developed with the variable spacing scheme produced similar dose distributions to the original VDR plans. For plans with complex angular MU distributions, the number of sectors increased up to four in the CDR plans in order to maintain the original plan quality. Since each sector was delivered with a different dose rate, extra mode-up time (xMOT) was needed between the transitions of the successive sectors during delivery. On average, the delivery times of the CDR plans were approximately less than 1 min longer than the treatment times of the VDR plans, with an average of

  8. Ideas on DC-DC Converters for Delivery of Low Voltage and High Currents for the SLHC / ILC Detector Electronics in Magnetic field and Radiation environments

    CERN Document Server

    Dhawan, Satish; Neal, H; Sumner, R; Weber, M; Weber, R

    2007-01-01

    For more efficient power transport to the electronics embedded inside large colliding beam detectors, we explore the feasibility of supplying 48 Volts DC and using local DCDC conversion to 2 V (or lower, depending upon on the lithography of the embedded electronics) using switch mode regulators located very close to the front end electronics. These devices will be exposed to high radiation and high magnetic fields, 10 – 100 Mrads and 2 - 4 Tesla at the SLHC, and 20 Krads and 6 Tesla at the ILC.

  9. Quality assurance methodology for Varian RapidArc treatment plans.

    Science.gov (United States)

    Iftimia, Ileana; Cirino, Eileen T; Xiong, Li; Mower, Herbert W

    2010-09-01

    With the commercial introduction of the Varian RapidArc, a new modality for treatment planning and delivery, the need has arisen for consistent and efficient techniques for performing patient-specific quality assurance (QA) tests. In this paper we present our methodology for a RapidArc treatment plan QA procedure. For our measurements we used a 2D diode array (MapCHECK) embedded at 5 cm water equivalent depth in MapPHAN 5 phantom and an Exradin A16 ion chamber placed in six different positions in a cylindrical homogeneous phantom (QUASAR). We also checked the MUs for the RapidArc plans by using independent software (RadCalc). The agreement between Eclipse calculations and MapCHECK/MapPHAN5 measurements was evaluated using both absolute distance-to-agreement (DTA) and gamma index with 10% dose threshold (TH), 3% dose difference (DD), and 3 mm DTA. The average agreement was 94.4% for the DTA approach and 96.3% for the gamma index approach. In high-dose areas, the discrepancy between calculations and ion chamber measurements using the QUASAR phantom was within 4.5% for prostate cases. For the RadCalc calculations, we used the average SSD along the arc; however, for some patients the agreement for the MUs obtained with RadCalc versus Eclipse was inadequate (discrepancy > 5%). In these cases, the plan was divided into partial arc plans so that RadCalc could perform a better estimation of the MUs. The discrepancy was further reduced to within ~4% using this approach. Regardless of the variation in prescribed dose and location of the treated areas, we obtained very good results for all patients studied in this paper.

  10. Gas Tungsten Arc Welding and Plasma Arc Cutting. Teacher Edition.

    Science.gov (United States)

    Fortney, Clarence; And Others

    This welding curriculum guide treats two topics in detail: the care of tungsten electrodes and the entire concept of contamination control and the hafnium electrode and its importance in dual-air cutting systems that use compressed shop air for plasma arc cutting activities. The guide contains three units of instruction that cover the following…

  11. Dosimetric comparison of different multileaf collimators in volumetric modulated arc therapy for malignant pleural mesothelioma

    Institute of Scientific and Technical Information of China (English)

    Fuli Zhang; Jun Hou; Jianping Chen; Huayong Jiang; Weidong Xu; Yadi Wang; Junmao Gao; Qingzhi Liu; Na Lu; Diandian Chen; Bo Yao

    2015-01-01

    Objective The aiom of the study was to compare the impacts of two types of multileaf col imators (MLC) [standard MLC with a width of 10 mm (sMLC) and micro-MLC with a width of 5 mm (mMLC)] on volumetric modulated arc therapy (VMAT) planning for malignant pleural mesothelioma. Methods VMAT for ten patients with inoperable malignant pleural mesotheliomas was retrospectively planned with the sMLC and mMLC. Histogram-based dose-volume parameters of the planning target vol-ume (PTV) [conformity index (CI) and homogeneous index (HI)] and organs-at-risk were compared for VMAT plans with sMLC (sMLC-VMAT) and mMLC (mMLC-VMAT). Results The mMLC-VMAT plans were more ef icient (average delivery time: 2.67±1.49 min) than the sMLC-VMAT plans (average delivery time: 4.21 ± 2.03 min; P 0.05). In addition, significant dose sparing in the fraction of the ipsilateral lung volume receiving > 20 Gy (V20; 54.72 ± 27.08 vs 58.52 ± 29.30) and > 30 Gy (V30; 42.74 ± 27.86 vs 46.86 ± 31.49) radiation, respectively, was observed for the mMLC plans (P < 0.05). Conclusion Comparing sMLC-VMAT and mMLC-VMAT not only demonstrated the higher ef iciency and better optimal target coverage of mMLC-VMAT, but also considerably improved the dose sparing of the ipsilateral lung in the VMAT plans for malignant pleural mesothelioma.

  12. Contouring Guidelines for the Axillary Lymph Nodes for the Delivery of Radiation Therapy in Breast Cancer: Evaluation of the RTOG Breast Cancer Atlas

    Energy Technology Data Exchange (ETDEWEB)

    Gentile, Michelle S. [Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center of Northwestern University, Chicago, Illinois (United States); Usman, Asad A.; Neuschler, Erin I. [Department of Radiology, Robert H. Lurie Comprehensive Cancer Center of Northwestern University, Chicago, Illinois (United States); Sathiaseelan, Vythialinga; Hayes, John P. [Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center of Northwestern University, Chicago, Illinois (United States); Small, William, E-mail: WMSMALL@lumc.edu [Department of Radiation Oncology, Loyola University, Chicago, Illinois (United States)

    2015-10-01

    Purpose: The purpose of this study was to identify the axillary lymph nodes on pretreatment diagnostic computed tomography (CT) of the chest to determine their position relative to the anatomic axillary borders as defined by the Radiation Therapy Oncology Group (RTOG) breast cancer atlas for radiation therapy planning. Methods and Materials: Pretreatment diagnostic CT chest scans available for 30 breast cancer patients with clinically involved lymph nodes were fused with simulation CT. Contouring of axillary levels I, II, and III according to the RTOG guidelines was performed. Measurements were made from the area of distal tumor to the anatomic borders in 6 dimensions for each level. Results: Of the 30 patients, 100%, 93%, and 37% had clinical involvement of levels I, II, and III, respectively. The mean number of lymph nodes dissected was 13.6. The mean size of the largest lymph node was 2.4 cm. Extracapsular extension was seen in 23% of patients. In 97% of patients, an aspect of the involved lymph node lay outside of the anatomic border of a level. In 80% and 83% of patients, tumor extension was seen outside the cranial (1.78 ± 1.0 cm; range, 0.28-3.58 cm) and anterior (1.27 ± 0.92 cm; range, 0.24-3.58 cm) borders of level I, respectively. In 80% of patients, tumor extension was seen outside the caudal border of level II (1.36 ± 1.0 cm, range, 0.27-3.86 cm), and 0% to 33% of patients had tumor extension outside the remaining borders of all levels. Conclusions: To cover 95% of lymph nodes at the cranial and anterior borders of level I, an additional clinical target volume margin of 3.78 cm and 3.11 cm, respectively, is necessary. The RTOG guidelines may be insufficient for coverage of axillary disease in patients with clinical nodal involvement who are undergoing neoadjuvant chemotherapy, incomplete axillary dissection, or treatment with intensity modulated radiation therapy. In patients with pretreatment diagnostic CT chest scans, fusion with

  13. Dust in the arcs of Methone and Anthe

    CERN Document Server

    Sun, Kai-Lung; Spahn, Frank

    2015-01-01

    Methone and Anthe are two tiny moons (with diameter $<3$ km) in the inner part of Saturn's E ring. Both moons are embedded in an arc of dust particles. To understand the amount of micron-sized dust and their spatial distribution in these arcs, we model the source, dynamical evolution, and sinks of these dust in the arc. We assume hypervelocity impacts of micrometeoroids on the moons as source of these dust (Hedman et al., 2009), the so called impact-ejecta process (Krivov et al., 2003; Spahn et al., 2006). After ejecting and escaping from the moons, these micron-sized particles are subject to several perturbing forces, including gravitational perturbation from Mimas, oblateness of Saturn, Lorentz force, solar radiation pressure, and plasma drag. Particles can be either confined in the arcs due to corotational resonance with Mimas, as their source moons (Spitale et al., 2006; Cooper et al., 2008; Hedman et al., 2009), or pushed outward by plasma drag. Particle sinks are recollisions with the source moon, co...

  14. Peritoneal macrophages mediated delivery of chitosan/siRNA nanoparticle to the lesion site in a murine radiation-induced fibrosis model

    DEFF Research Database (Denmark)

    Nawroth, Isabel; Alsner, Jan; Deleuran, B.W.

    2013-01-01

    the uptake of chitosan/fluorescently labeled siRNA nanoparticles by peritoneal macrophages and their subsequent migration to the inflamed tissue in the RIF model. Results. We observed strong accumulation of the fluorescent signal in the lesion site of the irradiated leg up to 24 hours using the optical...... imaging system. We further confirm by immunohistochemical staining that Cy3 labeled siRNA resides in macrophages of the irradiated leg. Conclusion. We provide a proof-of-concept for host macrophage trafficking towards the inflamed region in a murine RIF model, which thereby suggests that the chitosan......Background. Radiation-induced fibrosis (RIF) is a dose-limiting complication of cancer radiotherapy and causes serious problems, i.e. restricted tissue flexibility, pain, ulceration or necrosis. Recently, we have successfully treated RIF in a mouse model by intraperitoneal administration...

  15. Skin delivery of epigallocatechin-3-gallate (EGCG) and hyaluronic acid loaded nano-transfersomes for antioxidant and anti-aging effects in UV radiation induced skin damage.

    Science.gov (United States)

    Avadhani, Kiran S; Manikkath, Jyothsna; Tiwari, Mradul; Chandrasekhar, Misra; Godavarthi, Ashok; Vidya, Shimoga M; Hariharapura, Raghu C; Kalthur, Guruprasad; Udupa, Nayanabhirama; Mutalik, Srinivas

    2017-11-01

    The present work attempts to develop and statistically optimize transfersomes containing EGCG and hyaluronic acid to synergize the UV radiation-protective ability of both compounds, along with imparting antioxidant and anti-aging effects. Transfersomes were prepared by thin film hydration technique, using soy phosphatidylcholine and sodium cholate, combined with high-pressure homogenization. They were characterized with respect to size, polydispersity index, zeta potential, morphology, entrapment efficiency, Fourier Transform Infrared Spectroscopy (FTIR), Differential Scanning Calorimetry (DSC), X-ray Diffraction (XRD), in vitro antioxidant activity and ex vivo skin permeation studies. Cell viability, lipid peroxidation, intracellular ROS levels and expression of MMPs (2 and 9) were determined in human keratinocyte cell lines (HaCaT). The composition of the transfersomes was statistically optimized by Design of Experiments using Box-Behnken design with four factors at three levels. The optimized transfersome formulation showed vesicle size, polydispersity index and zeta potential of 101.2 ± 6.0 nm, 0.245 ± 0.069 and -44.8 ± 5.24 mV, respectively. FTIR and DSC showed no interaction between EGCG and the selected excipients. XRD results revealed no form conversion of EGCG in its transfersomal form. The optimized transfersomes were found to increase the cell viability and reduce the lipid peroxidation, intracellular ROS and expression of MMPs in HaCaT cells. The optimized transfersomal formulation of EGCG and HA exhibited considerably higher skin permeation and deposition of EGCG than that observed with plain EGCG. The results underline the potential application of the developed transfersomes in sunscreen cream/lotions for improvement of UV radiation-protection along with deriving antioxidant and anti-aging effects.

  16. Hooded arc ion-source

    CERN Multimedia

    1972-01-01

    The positioning system for the hooded arc ion-source, shown prior to mounting, consists of four excentric shafts to locate the ion-source and central electrodes. It will be placed on the axis of the SC and introduced into the vacuum tank via the air locks visible in the foreground.

  17. Vacuum Gas Tungsten Arc Welding

    Science.gov (United States)

    Weeks, J. L.; Todd, D. T.; Wooten, J. R.

    1997-01-01

    A two-year program investigated vacuum gas tungsten arc welding (VGTAW) as a method to modify or improve the weldability of normally difficult-to-weld materials. After a vacuum chamber and GTAW power supply were modified, several difficult-to-weld materials were studied and key parameters developed. Finally, Incoloy 903 weld overlays were produced without microfissures.

  18. Rotating Drive for Electrical-Arc Machining

    Science.gov (United States)

    Fransen, C. D.

    1986-01-01

    Rotating drive improves quality of holes made by electrical-arc machining. Mechanism (Uni-tek, rotary head, or equivalent) attached to electrical-arc system. Drive rotates electrode as though it were mechanical drill, while an arc disintegrates metal in workpiece, thereby creating hole. Rotating electrode method often used in electric-discharge machining. NASA innovation is application of technique to electrical-arc machining.

  19. STRUVE arc and EUPOS® stations

    Science.gov (United States)

    Lasmane, Ieva; Kaminskis, Janis; Balodis, Janis; Haritonova, Diana

    2013-04-01

    The Struve Geodetic Arc was developed in Years 1816 to 1855, 200 years ago. Historic information on the points of the Struve Geodetic Arc are included in the UNESCO World Heritage list in 2005. Nevertheless, the sites of many points are still not identified nor included in the data bases nowadays. Originally STRUVE arc consisted of 258 main triangles with 265 triangulation points. Currently 34 of the original station points are identified and included in the in the UNESCO World Heritage list. identified original measurement points of the Meridian Arc are located in Sweden (7 points), Norway (15), Finland (83), Russia (1), Estonia (22), Latvia (16), Lithuania (18), Belorussia (28), Ukraine (59) and Moldova (27). In Year 2002 was initiated another large coverage project - European Position Determination System "EUPOS®". Currently there are about 400 continuously operating GNSS (Global Navigation Satellite Systems) stations covering EU countries Estonia, Latvia, Lithuania, Poland, Czech Republic, Slovakia, Hungary, Bulgaria, Romania and East European countries Ukraine and Moldavia. EUPOS® network is a ground based GNSS augmentation system widely used for geodesy, land surveying, geophysics and navigation. It gives the opportunity for fast and accurate position determination never available before. It is an honorable task to use the EUPOS® system for research of the Struve triangulation former sites. Projects with Struve arc can popularize geodesy, geo-information and its meaning in nowadays GIS and GNSS systems. Struve Arc and its points is unique cooperation cross-border object which deserve special attention because of their natural beauty and historical value for mankind. GNSS in geodesy discovers a powerful tool for the verification and validation of the height values of geodetic leveling benchmarks established historically almost 200 years ago. The differential GNSS and RTK methods appear very useful to identify vertical displacement of landscape by means of

  20. SU-E-T-105: An FMEA Survey of Intensity Modulated Radiation Therapy (IMRT) Step and Shoot Dose Delivery Failure Modes

    Energy Technology Data Exchange (ETDEWEB)

    Faught, J Tonigan; Johnson, J; Stingo, F; Kry, S; Court, L; Balter, P; Followill, D [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To assess the perception of TG-142 tolerance level dose delivery failures in IMRT and the application of FMEA process to this specific aspect of IMRT. Methods: An online survey was distributed to medical physicists worldwide that briefly described 11 different failure modes (FMs) covered by basic quality assurance in step- and-shoot IMRT at or near TG-142 tolerance criteria levels. For each FM, respondents estimated the worst case H&N patient percent dose error and FMEA scores for Occurrence, Detectability, and Severity. Demographic data was also collected. Results: 181 individual and three group responses were submitted. 84% were from North America. Most (76%) individual respondents performed at least 80% clinical work and 92% were nationally certified. Respondent medical physics experience ranged from 2.5–45 years (average 18 years). 52% of individual respondents were at least somewhat familiar with FMEA, while 17% were not familiar. Several IMRT techniques, treatment planning systems and linear accelerator manufacturers were represented. All FMs received widely varying scores ranging from 1–10 for occurrence, at least 1–9 for detectability, and at least 1–7 for severity. Ranking FMs by RPN scores also resulted in large variability, with each FM being ranked both most risky (1st ) and least risky (11th) by different respondents. On average MLC modeling had the highest RPN scores. Individual estimated percent dose errors and severity scores positively correlated (p<0.10) for each FM as expected. No universal correlations were found between the demographic information collected and scoring, percent dose errors, or ranking. Conclusion: FMs investigated overall were evaluated as low to medium risk, with average RPNs less than 110. The ranking of 11 FMs was not agreed upon by the community. Large variability in FMEA scoring may be caused by individual interpretation and/or experience, thus reflecting the subjective nature of the FMEA tool.

  1. MO-E-BRB-04: Real-Time Exit-Fluence Delivery Validation

    Energy Technology Data Exchange (ETDEWEB)

    Siebers, J. [University of Virginia Health System (United States)

    2015-06-15

    Recent high profile reports of technical failures and human errors causing severe radiation- induced injuries and deaths come in support of the sustained efforts to ensure patient safety in the delivery of radiation treatments. In addition, highly conformal radiation therapies and escalated fraction doses mandate increased and sustained accuracy of the entire radiotherapy process. Consequently, and as a Result of AAPM and ASTRO led efforts patient specific quality assurance for specialized radiation treatments such as IMRT, SRS/SBRT and Arc Therapy had become a three-tier process: Pre-treatment, during treatment, and post treatment patient specific QA. Traditional patient QA consists of pre-treatment data transfer integrity dosimetric verifications and during-treatment geometric verifications. However, as treatment adaptation becomes closer to deployment in the clinics, during treatment validation via exit detectors had become a realistic QA option, permitting plan assessment in near real time. Post-treatment, machine logs allow comparisons of a range of mechanical parameters. A combination of these techniques could be used in evaluating inter-fraction, and intra-fraction delivery over a long time period such as an year, to evaluate the significant errors per site, per treatment technique. This type of data mining over longer periods of time provides the potential to recognize suboptimal radiation treatments, while allowing to identify systematic, possibly significant errors. This would allow creation of a data base of realized errors, small and large in dosimetry that could be for process or equipment improvement. This educational symposium will describe and review patient QA techniques, results, and strategies for patient specific quality assurance. Learning Objectives: review the goals of pre-treatment QA for various specialized procedures review methods and means for pre-treatment QA, limitations and tolerances review the scenarios where Varian/Tomo Log files

  2. Magnification Bias in Gravitational Arc Statistics

    Energy Technology Data Exchange (ETDEWEB)

    Caminha, G. B. [Rio de Janeiro, CBPF; Estrada, J. [Fermilab; Makler, M. [Rio de Janeiro, CBPF

    2013-08-29

    The statistics of gravitational arcs in galaxy clusters is a powerful probe of cluster structure and may provide complementary cosmological constraints. Despite recent progresses, discrepancies still remain among modelling and observations of arc abundance, specially regarding the redshift distribution of strong lensing clusters. Besides, fast "semi-analytic" methods still have to incorporate the success obtained with simulations. In this paper we discuss the contribution of the magnification in gravitational arc statistics. Although lensing conserves surface brightness, the magnification increases the signal-to-noise ratio of the arcs, enhancing their detectability. We present an approach to include this and other observational effects in semi-analytic calculations for arc statistics. The cross section for arc formation ({\\sigma}) is computed through a semi-analytic method based on the ratio of the eigenvalues of the magnification tensor. Using this approach we obtained the scaling of {\\sigma} with respect to the magnification, and other parameters, allowing for a fast computation of the cross section. We apply this method to evaluate the expected number of arcs per cluster using an elliptical Navarro--Frenk--White matter distribution. Our results show that the magnification has a strong effect on the arc abundance, enhancing the fraction of arcs, moving the peak of the arc fraction to higher redshifts, and softening its decrease at high redshifts. We argue that the effect of magnification should be included in arc statistics modelling and that it could help to reconcile arcs statistics predictions with the observational data.

  3. Laboratory experiments on arc deflection and instability

    Energy Technology Data Exchange (ETDEWEB)

    Zweben, S.; Karasik, M.

    2000-03-21

    This article describes experiments on arc deflection instability carried out during the past few years at the Princeton University Plasma Physics Laboratory (PPPL). The approach has been that of plasma physicists interested in arcs, but they believe these results may be useful to engineers who are responsible for controlling arc behavior in large electric steel furnaces.

  4. Making Conductive Polymers By Arc Tracking

    Science.gov (United States)

    Daech, Alfred F.

    1992-01-01

    Experimental technique for fabrication of electrically conductive polymeric filaments based on arc tracking, in which electrical arc creates conductive carbon track in material that initially was insulator. Electrically conductive polymeric structures made by arc tracking aligned along wire on which formed. Alignment particularly suited to high conductivity and desirable in materials intended for testing as candidate superconductors.

  5. Thermal analysis of an arc heater electrode with a rotating arc foot

    Science.gov (United States)

    Milos, Frank S.; Shepard, Charles E.

    1993-01-01

    A smoothly rotating arc foot and an arc foot that jumps between multiple sticking points were analyzed using analytic formulations and numerical solution procedures. For each case the temperature distribution for a copper electrode was obtained for the plausible range of operating conditions. It is shown that the smoothly rotating arc foot is an extremely safe mode of operation, whereas the jumping arc foot produces excessively high electrode surface temperatures which are not greatly alleviated by increasing the average rotational frequency of the arc foot. It is suggested to eliminate arc-foot rotation and rely on the distribution of fixed electrodes with stationary arc attachment to avoid electrode failure at high current.

  6. Dosimetry Comparison between Volumetric Modulated Arc Therapy with RapidArc and Fixed Field Dynamic IMRT for Local-Regionally Advanced Nasopharyngeal Carcinoma

    Institute of Scientific and Technical Information of China (English)

    Bao-min Zheng; Xiao-xia Dong; Hao Wu; You-jia Duan; Shu-kui Han; Yan Sun

    2011-01-01

    Objective:A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC).Methods:The CT scan data sets of 20 patients of locally advanced NPC were selected randomly.The plans were managed using volumetric modulated arc with RapidArc and fixed nine-field coplanar dynamic intensity-modulated radiotherapy (IMRT) for these patients.The dosimetry of the planning target volumes (PTV),the organs at risk (OARs) and the healthy tissue were evaluated.The dose prescription was set to 70 Gy to the primary tumor and 60 Gy to the clinical target volumes (CTV) in 33 fractions.Each fraction applied daily,five fractions per week.The monitor unit (MU) values and the delivery time were scored to evaluate the expected treatment efficiency.Results:Both techniques had reached clinical treatment's requirement.The mean dose (Dmean),maximum dose (Dmax) and minimum dose (Dmin) in RapidArc and fixed field IMRT for PTV were 68.4±0.6 Gy,74.8±0.9 Gy and 56.8±1.1 Gy; and 67.6±0.6 Gy,73.8±0.4 Gy and 57.5±0.6 Gy (P<0.05),respectively.Homogeneity index was 78.85±1.29 in RapidArc and 80.34±0.54 (P<0.05) in IMRT.The conformity index (CI:95%) was 0.78±0.01 for both techniques (P>0.05).Compared to IMRT,RapidArc allowed a reduction of Dmean to the brain stem,mandible and optic nerves of 14.1% (P<0.05),5.6% (P<0.05) and 12.2% (P<0.05),respectively.For the healthy tissue and the whole absorbed dose,Dmean of RapidArc was reduced by 3.6% (P<0.05),and 3.7% (P<0.05),respectively.The Dmean to the parotids,the spinal cord and the lens had no statistical difference among them.The mean MU values of RapidArc and IMRT were 550 and 1,379.The mean treatment time of RapidArc and IMRT was 165 s and 447 s.Compared to IMRT,the delivery time and the MU values of RapidArc were reduced by 63% and 60%,respectively.Conclusion:For locally advanced NPC,both RapidArc and IMRT reached

  7. Tectonomagmatism in continental arcs: evidence from the Sark arc complex

    Science.gov (United States)

    Gibbons, Wes; Moreno, Teresa

    2002-07-01

    The island of Sark (Channel Islands, UK) exposes syntectonic plutons and country rock gneisses within a Precambrian (Cadomian) continental arc. This Sark arc complex records sequential pulses of magmatism over a period of 7 Ma (ca. 616-609 Ma). The earliest intrusion (ca. 616 Ma) was a composite sill that shows an ultramafic base overlain by a magma-mingled net vein complex subsequently deformed at near-solidus temperatures into the amphibolitic and tonalitic Tintageu banded gneisses. The deformation was synchronous with D 2 deformation of the paragneissic envelope, with both intrusion and country rock showing flat, top-to-the-south LS fabrics. Later plutonism injected three homogeneous quartz diorite-granodiorite sheets: the Creux-Moulin pluton (150-250 m; ca. 614 Ma), the Little Sark pluton (>700 m; 611 Ma), and the Northern pluton (>500 m; 609 Ma). Similar but thinner sheets in the south (Derrible-Hogsback-Dixcart) and west (Port es Saies-Brecqhou) are interpreted as offshoots from the Creux-Moulin pluton and Little Sark pluton, respectively. All these plutons show the same LS fabric seen in the older gneisses, with rare magmatic fabrics and common solid state fabrics recording syntectonic crystallisation and cooling. The cooling rate increased rapidly with decreasing crystallisation age: >9 Ma for the oldest intrusion to cool to lower amphibolite conditions, 7-8 Ma for the Creux Moulin pluton, 5-6 Ma for the Little Sark pluton, and 10 -14 s -1) that focussed extensional deformation into the Sark area. The increased rates of extension allowed ingress of the subsequent quartz diorite-granodiorite sheets, although strain rate slowly declined as the whole complex cooled during exhumation. The regional architecture of syntectonic Cadomian arc complexes includes flat-lying "Sark-type" and steep "Guernsey-type" domains produced synchronously in shear zone networks induced by oblique subduction: a pattern seen in other continental arcs such as that running from Alaska

  8. Diagnosis of TIG welding based on ultraviolet radiation

    Institute of Scientific and Technical Information of China (English)

    Li Zhiyong; Gu Xiaoyan; Wang Bao

    2009-01-01

    Through collecting the radiation of tungsten inert gas (TIG) welding arc, the radiation distribution in ultraviolet zone is analyzed in order to study the variation rule of ultraviolet radiation versus welding condition. The explanation for the variation is also provided bused on spectral radiation theory of arc light. Furthermore, through analysis of disturbanee factors, the integral intensity signal of radiation in ultraviolet zone is applied for diagnosis of welding process. The spectral signal of ultraviolet radiation can reflect the disturbance factors and welding conditions, which can be used for online diagnosis of welding process.

  9. Multistage CSR microbunching gain development in transport or recirculation arcs

    CERN Document Server

    Tsai, Cheng-Ying; Li, Rui; Tennant, Chris

    2015-01-01

    Coherent synchrotron radiation (CSR) induced microbunching instability has been one of the most challenging issues in the design of modern accelerators. A linear Vlasov solver has been developed [1] and applied to investigate the physical processes of microbunching gain amplification for several example lattices [2]. In this paper, by further extending the concept of stage gain as proposed by Huang and Kim [3], we develop a method to characterize the microbunching development in terms of stage orders that allow the quantitative comparison of optics impacts on microbunching gain for different lattices. We find that the microbunching instability in our demonstrated arcs has a distinguishing feature of multistage amplification (e.g, up to 6th stage amplification for our example transport arcs, in contrast to two-stage amplification for a typical 4-dipole bunch compressor chicane). We also try to connect lattice optics pattern with the obtained stage gain functions by a physical interpretation. This Vlasov analys...

  10. TH-C-12A-01: Develop a Patient-Specific QA Program for Radiation Therapy with On-Board MRI

    Energy Technology Data Exchange (ETDEWEB)

    Li, H; Rodriguez, V; Green, O; Hu, Y; Kashani, R; Wooten, H; Yang, D; Mutic, S [Washington University in St Louis, St Louis, MO (United States)

    2014-06-15

    Purpose: This work describes development of the first patient-specific quality assurance (QA) program for magnetic resonance imaging guided radiation therapy (MR-IGRT). Methods: The program consisted of following components: 1) multipoint ionization chamber (IC) measurement using a 15 cm3 cubic phantom, 2) 2D stacked radiographic film dosimetry using a 30×30×20 cm3 phantom with multiple inserted ICs, 3) 3D ArcCHECK measurement with a centrally inserted IC, 4) machine delivery file verification, 5) 3D Monte-Carlo dose re-calculation with machine delivery file and phantom CT, 6) 2-head mode delivery validation in case of a malfunctioning head, and 7) independent beam-on time calculation for non-IMRT fields. Both ADCL calibrated ICs and ArcCHECK were MRI compatible. Experimental data were analyzed for the first 10 patients treated at our institution. Results: The customized phantoms allowed measuring multiple points with ICs in one delivery. Absolute IC measurements were all within 3% in all phantom geometry/shape/material combinations. Despite known uncertainty associated with film dosimetry, passing rates greater than 90% were achieved in both absolute and composite modes using TG-129 criteria. Due to the simultaneous irradiation by three radiation sources, ArcCHECK was used as a 3D relative dosimeter with angular and energy dependences uncorrected. 95–100% passing rates were obtained and the centrally inserted IC measurement assured that the overall dose normalization was within 3%. Machine delivery file verification and MC recalculated dose to the phantom results showed 98–100% passing rates, providing opportunity of moving from gamma passing rates to patient DVHbased QA metrics. Same results were obtained for the 2-head delivery mode. Manual beam-on time calculation for non-IMRT fields showed better than 5% agreement. Conclusion: We have successfully developed the first MRIGRT patient specific QA program by adopting experimental and computational dosimetry

  11. A Contribution to Arc Length Discussion

    Directory of Open Access Journals (Sweden)

    Stephan Egerland

    2015-09-01

    Full Text Available Abstract An investigation was raising the question: "What does 'arc length' mean?" Actually, it is considered expressing a kind of natural relationship between arc voltage and arc column shape. Statements such as "The higher the voltage the longer the arc" or "The arc voltage proves approximately proportional to the arc length", are frequently noticed in this conjunction. However, the author suggests that there is no general possibility of describing 'arc length' over the whole welding process range. Instances are represented in this paper, showing both theoretical attempts of definition and practical observations. This paper intends to contribute to a serious discussion of something trivial, indeed very well-known or used among welding experts, but actually yet hardly understood, at least as when it comes to closer examination

  12. Hendee's radiation therapy physics

    CERN Document Server

    Pawlicki, Todd; Starkschall, George

    2016-01-01

    The publication of this fourth edition, more than ten years on from the publication of Radiation Therapy Physics third edition, provides a comprehensive and valuable update to the educational offerings in this field. Led by a new team of highly esteemed authors, building on Dr Hendee’s tradition, Hendee’s Radiation Therapy Physics offers a succinctly written, fully modernised update. Radiation physics has undergone many changes in the past ten years: intensity-modulated radiation therapy (IMRT) has become a routine method of radiation treatment delivery, digital imaging has replaced film-screen imaging for localization and verification, image-guided radiation therapy (IGRT) is frequently used, in many centers proton therapy has become a viable mode of radiation therapy, new approaches have been introduced to radiation therapy quality assurance and safety that focus more on process analysis rather than specific performance testing, and the explosion in patient-and machine-related data has necessitated an ...

  13. SU-E-T-539: Fixed Versus Variable Optimization Points in Combined-Mode Modulated Arc Therapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Kainz, K; Prah, D; Ahunbay, E; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2014-06-01

    Purpose: A novel modulated arc therapy technique, mARC, enables superposition of step-and-shoot IMRT segments upon a subset of the optimization points (OPs) of a continuous-arc delivery. We compare two approaches to mARC planning: one with the number of OPs fixed throughout optimization, and another where the planning system determines the number of OPs in the final plan, subject to an upper limit defined at the outset. Methods: Fixed-OP mARC planning was performed for representative cases using Panther v. 5.01 (Prowess, Inc.), while variable-OP mARC planning used Monaco v. 5.00 (Elekta, Inc.). All Monaco planning used an upper limit of 91 OPs; those OPs with minimal MU were removed during optimization. Plans were delivered, and delivery times recorded, on a Siemens Artiste accelerator using a flat 6MV beam with 300 MU/min rate. Dose distributions measured using ArcCheck (Sun Nuclear Corporation, Inc.) were compared with the plan calculation; the two were deemed consistent if they agreed to within 3.5% in absolute dose and 3.5 mm in distance-to-agreement among > 95% of the diodes within the direct beam. Results: Example cases included a prostate and a head-and-neck planned with a single arc and fraction doses of 1.8 and 2.0 Gy, respectively. Aside from slightly more uniform target dose for the variable-OP plans, the DVHs for the two techniques were similar. For the fixed-OP technique, the number of OPs was 38 and 39, and the delivery time was 228 and 259 seconds, respectively, for the prostate and head-and-neck cases. For the final variable-OP plans, there were 91 and 85 OPs, and the delivery time was 296 and 440 seconds, correspondingly longer than for fixed-OP. Conclusion: For mARC, both the fixed-OP and variable-OP approaches produced comparable-quality plans whose delivery was successfully verified. To keep delivery time per fraction short, a fixed-OP planning approach is preferred.

  14. Planning for mARC treatments with the Eclipse treatment planning system.

    Science.gov (United States)

    Sarkar, Vikren; Huang, Long; Rassiah-Szegedi, Prema; Zhao, Hui; Huang, Jessica; Szegedi, Martin; Salter, Bill J

    2015-03-08

    While modulated arc (mARC) capabilities have been available on Siemens linear accelerators for almost two years now, there was, until recently, only one treatment planning system capable of planning these treatments. The Eclipse treatment planning system now offers a module that can plan for mARC treatments. The purpose of this work was to test the module to determine whether it is capable of creating clinically acceptable plans. A total of 23 plans were created for various clinical sites and all plans delivered without anomaly. The average 3%/3 mm gamma pass rate for the plans was 98.0%, with a standard deviation of 1.7%. For a total of 14 plans, an equivalent static gantry IMRT plan was also created to compare delivery time. In all but two cases, the mARC plans delivered significantly faster than the static gantry plan. We have confirmed the successful creation of mARC plans that are deliverable with high fidelity on an ARTISTE linear accelerator, thus demonstrating the successful implementation of the Eclipse mARC module.

  15. Zircon Recycling in Arc Intrusions

    Science.gov (United States)

    Miller, J.; Barth, A.; Matzel, J.; Wooden, J.; Burgess, S.

    2008-12-01

    Recycling of zircon has been well established in arc intrusions and arc volcanoes, but a better understanding of where and how zircons are recycled can help illuminate how arc magma systems are constructed. To that end, we are conducting age, trace element (including Ti-in-zircon temperatures; TzrnTi) and isotopic studies of zircons from the Late Cretaceous (95-85 Ma) Tuolumne Intrusive Suite (TIS) in the Sierra Nevada Batholith (CA). Within the TIS zircons inherited from ancient basement sources and/or distinctly older host rocks are uncommon, but recycled zircon antecrysts from earlier periods of TIS-related magmatism are common and conspicuous in the inner and two most voluminous units of the TIS, the Half Dome and Cathedral Peak Granodiorites. All TIS units have low bulk Zr ([Zr]825°C), [Zr] in the TIS is a factor of 2 to 3 lower than saturation values. Low [Zr] in TIS rocks might be attributed to a very limited supply of zircon in the source, by disequilibrium melting and rapid melt extraction [1], by melting reactions involving formation of other phases that can incorporate appreciable Zr [2], or by removal of zircon at an earlier stage of magma evolution. Based on a preliminary compilation of literature data, low [Zr] is common to Late Cretaceous N.A. Cordilleran granodioritic/tonalitic intrusions (typically Tzrnsat [3]. A corollary is that slightly older zircon antecrysts that are common in the inner units of the TIS could be considered inherited if they are derived from remelting of slightly older intrusions. Remelting at such low temperatures in the arc would require a source of external water. Refs: [1] Sawyer, J.Pet 32:701-738; [2] Fraser et al, Geology 25:607-610; [3] Harrison et al, Geology 35:635- 638

  16. Reverse-Contrast Imaging and Targeted Radiation Therapy of Advanced Pancreatic Cancer Models

    Energy Technology Data Exchange (ETDEWEB)

    Thorek, Daniel L.J., E-mail: dthorek1@jhmi.edu [Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, The Johns Hopkins School of Medicine, Baltimore, MD (United States); Kramer, Robin M. [Tri-Institutional Training Program in Laboratory Animal Medicine and Science, Memorial Sloan-Kettering Cancer Center (MSKCC), Weill Cornell Medical College, The Rockefeller University, New York, NY (United States); Chen, Qing; Jeong, Jeho; Lupu, Mihaela E. [Department of Medical Physics, MSKCC, New York, NY (United States); Lee, Alycia M.; Moynahan, Mary E.; Lowery, Maeve [Department of Medicine, MSKCC, New York, NY (United States); Ulmert, David [Molecular Pharmacology and Chemistry Program, MSKCC, New York, NY (United States); Department of Surgery (Urology), Skåne University Hospital, Malmö (Sweden); Zanzonico, Pat; Deasy, Joseph O.; Humm, John L. [Department of Medical Physics, MSKCC, New York, NY (United States); Russell, James, E-mail: russellj@mskcc.org [Department of Medical Physics, MSKCC, New York, NY (United States)

    2015-10-01

    Purpose: To evaluate the feasibility of delivering experimental radiation therapy to tumors in the mouse pancreas. Imaging and treatment were performed using combined CT (computed tomography)/orthovoltage treatment with a rotating gantry. Methods and Materials: After intraperitoneal administration of radiopaque iodinated contrast, abdominal organ delineation was performed by x-ray CT. With this technique we delineated the pancreas and both orthotopic xenografts and genetically engineered disease. Computed tomographic imaging was validated by comparison with magnetic resonance imaging. Therapeutic radiation was delivered via a 1-cm diameter field. Selective x-ray radiation therapy of the noninvasively defined orthotopic mass was confirmed using γH2AX staining. Mice could tolerate a dose of 15 Gy when the field was centered on the pancreas tail, and treatment was delivered as a continuous 360° arc. This strategy was then used for radiation therapy planning for selective delivery of therapeutic x-ray radiation therapy to orthotopic tumors. Results: Tumor growth delay after 15 Gy was monitored, using CT and ultrasound to determine the tumor volume at various times after treatment. Our strategy enables the use of clinical radiation oncology approaches to treat experimental tumors in the pancreas of small animals for the first time. We demonstrate that delivery of 15 Gy from a rotating gantry minimizes background healthy tissue damage and significantly retards tumor growth. Conclusions: This advance permits evaluation of radiation planning and dosing parameters. Accurate noninvasive longitudinal imaging and monitoring of tumor progression and therapeutic response in preclinical models is now possible and can be expected to more effectively evaluate pancreatic cancer disease and therapeutic response.

  17. Premature delivery

    Directory of Open Access Journals (Sweden)

    Bernardita Donoso Bernales

    2012-09-01

    Full Text Available Preterm delivery is the single most important cause of perinatal morbidity and mortality. In Chile, preterm births have increased in the past decade, although neonatal morbidity and mortality attributable to it shows a downward trend, thanks to improvements in neonatal care of premature babies, rather than the success of obstetric preventive and therapeutic strategies. This article describes clinical entities, disease processes and conditions that constitute predisposing factors of preterm birth, as well as an outline for the prevention and clinical management of women at risk of preterm birth.

  18. Estimation of internal organ motion-induced variance in radiation dose in non-gated radiotherapy

    Science.gov (United States)

    Zhou, Sumin; Zhu, Xiaofeng; Zhang, Mutian; Zheng, Dandan; Lei, Yu; Li, Sicong; Bennion, Nathan; Verma, Vivek; Zhen, Weining; Enke, Charles

    2016-12-01

    In the delivery of non-gated radiotherapy (RT), owing to intra-fraction organ motion, a certain degree of RT dose uncertainty is present. Herein, we propose a novel mathematical algorithm to estimate the mean and variance of RT dose that is delivered without gating. These parameters are specific to individual internal organ motion, dependent on individual treatment plans, and relevant to the RT delivery process. This algorithm uses images from a patient’s 4D simulation study to model the actual patient internal organ motion during RT delivery. All necessary dose rate calculations are performed in fixed patient internal organ motion states. The analytical and deterministic formulae of mean and variance in dose from non-gated RT were derived directly via statistical averaging of the calculated dose rate over possible random internal organ motion initial phases, and did not require constructing relevant histograms. All results are expressed in dose rate Fourier transform coefficients for computational efficiency. Exact solutions are provided to simplified, yet still clinically relevant, cases. Results from a volumetric-modulated arc therapy (VMAT) patient case are also presented. The results obtained from our mathematical algorithm can aid clinical decisions by providing information regarding both mean and variance of radiation dose to non-gated patients prior to RT delivery.

  19. H_2O and CO_2 in magmas from the Mariana arc and back arc systems

    OpenAIRE

    Newman, Sally; Stolper, Edward; STERN, Robert

    2000-01-01

    We examined the H2O and CO2 contents of glasses from lavas and xenoliths from the Mariana arc system, an intraoceanic convergent margin in the western Pacific, which contains an active volcanic arc, an actively spreading back arc basin, and active behind-the-arc cross-chain volcanoes. Samples include (1) glass rims from Mariana arc, Mariana trough, and cross-chain submarine lavas; (2) glass inclusions in arc and trough phenocrysts; and (3) glass inclusions from a gabbro + anorthosite xenolith...

  20. Arc Root Attachment on the Anode Surface of Arc Plasma Torch Observed with a Novel Method

    Institute of Scientific and Technical Information of China (English)

    PAN Wen-Xia; LI Teng; MENG Xian; CHEN Xi; WU Cheng-Kang

    2005-01-01

    @@ The arc-root attachment on the anode surface of a dc non-transferred arc plasma torch has been successfullyobserved using a novel approach. A specially designed copper mirror with a boron nitride film coated on itssurface central-region is employed to avoid the effect of intensive light emitted from the arc column upon theobservation of weakly luminous arc root. It is found that the arc-root attachment is diffusive on the anode surfaceof the argon plasma torch, while constricted arc roots often occur when hydrogen or nitrogen is added into argonas the plasma-forming gas.

  1. Reappraisal of the Arc-Arc Collision in Taiwan

    Directory of Open Access Journals (Sweden)

    Tetsuzo Seno and Yoshiaki Kawanishi

    2009-01-01

    Full Text Available Al though it is evident that Taiwan has been formed by the collision of the west-facing Luzon arc with the Eurasian continental mar gin, _ main a lot of enigmas in this collision. The major ones are: (1 a trans form fault presently connecting the Manila and Ryukyu Trenches in the Philippine Sea _ Eurasia relative motion direction is missing, and in stead, the Ryukyu Trench ex tends near off shore E. Tai wan, (2 the western edge of the intermediate-depth seismicity associated with We pro pose a new model of the collision in Tai wan to re solve these enigmas, assuming that the southern Ryukyu forearc was mi grating to the south west with respect to Eurasia for the past several m.y. and the Luzon arc has been colliding with this actively migrating Ryukyu forearc. The northern most Luzon arc is divided into two parts by the NNW line directing along the Philippine Sea - Ryukyu forearc motion from its initial intersection point with the Ryukyu Trench; the part west of this line has been obducted on the Ryukyu forearc-Eurasian mar gin, producing the collision orogen in Taiwan, and the part east of it has been subducted beneath the Ryukyu forearc. This evolutionary scenario resolves enigmas (1 and (2 kinematically. This model also predicts that the South China Sea slab has to be torn by the west ward component of the motion of the subducting Philippine Sea slab to Eurasia. This would have brought large lateral compression in the shallow portion of the Philippine Sea slab at its western border, which might lead to buck ling of the slab causing the ob served undulated gravity anomaly.

  2. Synchrotron radiation and biomedical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Luccio, A.

    1986-08-01

    In this lecture we describe the characteristics of Synchrotron radiation as a source of X rays. We discuss the properties of SR arc sources, wigglers, undulators and the use of backscattering of laser light. Applications to angiography, X ray microscopy and tomography are reviewed. 16 refs., 23 figs.

  3. The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy

    NARCIS (Netherlands)

    Mans, Anton; Schuring, Danny; Arends, Mark P.; Vugts, Cornelia A. J. M.; Wolthaus, Jochem W. H.; Lotz, Heidi T.; Admiraal, Marjan; Louwe, Rob J. W.; Ollers, Michel C.; van de Kamer, Jeroen B.

    2016-01-01

    In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, ine

  4. The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy

    Directory of Open Access Journals (Sweden)

    Fogliata Antonella

    2008-09-01

    Full Text Available Abstract Background To expand and test the dosimetric procedure, known as GLAaS, for amorphous silicon detectors to the RapidArc intensity modulated arc delivery with Varian infrastructures and to test the RapidArc dosimetric reliability between calculation and delivery. Methods The GLAaS algorithm was applied and tested on a set of RapidArc fields at both low (6 MV and high (18 MV beam energies with a PV-aS1000 detector. Pilot tests for short arcs were performed on a 6 MV beam associated to a PV-aS500. RapidArc is a novel planning and delivery method in the category of intensity modulated arc therapies aiming to deliver highly modulated plans with variable MLC shapes, dose rate and gantry speed during rotation. Tests were repeated for entire (360 degrees gantry rotations on composite dose plans and for short partial arcs (of ~6 or 12 degrees to assess GLAaS and RapidArc mutual relationships on global and fine delivery scales. The gamma index concept of Low and the Modulation Index concept of Webb were applied to compare quantitatively TPS dose matrices and dose converted PV images. Results The Gamma Agreement Index computed for a Distance to Agreement of 3 mm and a Dose Difference (ΔD of 3% was, as mean ± 1 SD, 96.7 ± 1.2% at 6 MV and 94.9 ± 1.3% at 18 MV, over the field area. These findings deteriorated slightly is ΔD was reduced to 2% (93.4 ± 3.2% and 90.1 ± 3.1%, respectively and improved with ΔD = 4% (98.3 ± 0.8% and 97.3 ± 0.9%, respectively. For all tests a grid of 1 mm and the AAA photon dose calculation algorithm were applied. The spatial resolution of the PV-aS1000 is 0.392 mm/pxl. The Modulation Index for calculations resulted 17.0 ± 3.2 at 6 MV and 15.3 ± 2.7 at 18 MV while the corresponding data for measurements were: 18.5 ± 3.7 and 17.5 ± 3.7. Partial arcs findings were (for ΔD = 3%: GAI = 96.7 ± 0.9% for 6° rotations and 98.0 ± 1.1% for 12° rotations. Conclusion The GLAaS method can be considered as a valid

  5. Programming ArcGIS with Python cookbook

    CERN Document Server

    Pimpler, Eric

    2015-01-01

    Programming ArcGIS with Python Cookbook, Second Edition, is written for GIS professionals who wish to revolutionize their ArcGIS workflow with Python. Whether you are new to ArcGIS or a seasoned professional, you almost certainly spend time each day performing various geoprocessing tasks. This book will teach you how to use the Python programming language to automate these geoprocessing tasks and make you a more efficient and effective GIS professional.

  6. Miniaturized cathodic arc plasma source

    Science.gov (United States)

    Anders, Andre; MacGill, Robert A.

    2003-04-15

    A cathodic arc plasma source has an anode formed of a plurality of spaced baffles which extend beyond the active cathode surface of the cathode. With the open baffle structure of the anode, most macroparticles pass through the gaps between the baffles and reflect off the baffles out of the plasma stream that enters a filter. Thus the anode not only has an electrical function but serves as a prefilter. The cathode has a small diameter, e.g. a rod of about 1/4 inch (6.25 mm) diameter. Thus the plasma source output is well localized, even with cathode spot movement which is limited in area, so that it effectively couples into a miniaturized filter. With a small area cathode, the material eroded from the cathode needs to be replaced to maintain plasma production. Therefore, the source includes a cathode advancement or feed mechanism coupled to cathode rod. The cathode also requires a cooling mechanism. The movable cathode rod is housed in a cooled metal shield or tube which serves as both a current conductor, thus reducing ohmic heat produced in the cathode, and as the heat sink for heat generated at or near the cathode. Cooling of the cathode housing tube is done by contact with coolant at a place remote from the active cathode surface. The source is operated in pulsed mode at relatively high currents, about 1 kA. The high arc current can also be used to operate the magnetic filter. A cathodic arc plasma deposition system using this source can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.

  7. Boxicity of Circular Arc Graphs

    OpenAIRE

    Bhowmick, Diptendu; Chandran, L. Sunil

    2008-01-01

    A $k$-dimensional box is the cartesian product $R_1 \\times R_2 \\times ... \\times R_k$ where each $R_i$ is a closed interval on the real line. The {\\it boxicity} of a graph $G$, denoted as $box(G)$, is the minimum integer $k$ such that $G$ can be represented as the intersection graph of a collection of $k$-dimensional boxes: that is two vertices are adjacent if and only if their corresponding boxes intersect. A circular arc graph is a graph that can be represented as the intersection graph of ...

  8. The Team Orienteering Arc Routing Problem

    OpenAIRE

    Archetti, Claudia; Speranza, M. Grazia; Corberan, Angel; Sanchís Llopis, José María; Plana, Isaac

    2014-01-01

    The team orienteering arc routing problem (TOARP) is the extension to the arc routing setting of the team orienteering problem. In the TOARP, in addition to a possible set of regular customers that have to be serviced, another set of potential customers is available. Each customer is associated with an arc of a directed graph. Each potential customer has a profit that is collected when it is serviced, that is, when the associated arc is traversed. A fleet of vehicles with a given maximum trav...

  9. Class `E` protective headwear: electric arc exposure

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.

    1997-04-01

    A series of tests were conducted using electric arcs under laboratory conditions to determine what, if any, damages can be inflicted upon class `E` hard hats. Ten hard hats were subjected to different levels of arc exposure to see if the hat would ignite, melt, drip, stick to the head, etc. It was noted that there is no standard on hard hat exposure to an electric arc. It was recommended that the CSA committee revise the protective headwear standard to include a requirement for flame/arc resistance, including specification of pass/fail criteria. 1 tab., 3 figs.

  10. Metals purification by improved vacuum arc remelting

    Science.gov (United States)

    Zanner, Frank J.; Williamson, Rodney L.; Smith, Mark F.

    1994-12-13

    The invention relates to improved apparatuses and methods for remelting metal alloys in furnaces, particularly consumable electrode vacuum arc furnaces. Excited reactive gas is injected into a stationary furnace arc zone, thus accelerating the reduction reactions which purify the metal being melted. Additionally, a cooled condensation surface is disposed within the furnace to reduce the partial pressure of water in the furnace, which also fosters the reduction reactions which result in a purer produced ingot. Methods and means are provided for maintaining the stationary arc zone, thereby reducing the opportunity for contaminants evaporated from the arc zone to be reintroduced into the produced ingot.

  11. Feedback Linearization Based Arc Length Control for Gas Metal Arc Welding

    DEFF Research Database (Denmark)

    Thomsen, Jesper Sandberg

    2005-01-01

    In this paper a feedback linearization based arc length controller for gas metal arc welding (GMAW) is described. A nonlinear model describing the dynamic arc length is transformed into a system where nonlinearities can be cancelled by a nonlinear state feedback control part, and thus, leaving only...

  12. JEMMRLA - Electron Model of a Muon RLA with Multi-pass Arcs

    Energy Technology Data Exchange (ETDEWEB)

    Bogacz, Slawomir Alex; Krafft, Geoffrey A.; Morozov, Vasiliy S.; Roblin, Yves R.

    2013-06-01

    We propose a demonstration experiment for a new concept of a 'dogbone' RLA with multi-pass return arcs -- JEMMRLA (Jlab Electron Model of Muon RLA). Such an RLA with linear-field multi-pass arcs was introduced for rapid acceleration of muons for the next generation of Muon Facilities. It allows for efficient use of expensive RF while the multi-pass arc design based on linear combined-function magnets exhibits a number of advantages over separate-arc or pulsed-arc designs. Here we describe a test of this concept by scaling a GeV scale muon design for electrons. Scaling muon momenta by the muon-to-electron mass ratio leads to a scheme, in which a 4.5 MeV electron beam is injected in the middle of a 3 MeV/pass linac with two double-pass return arcs and is accelerated to 18 MeV in 4.5 passes. All spatial dimensions including the orbit distortion are scaled by a factor of 7.5, which arises from scaling the 200 MHz muon RF to a readily available 1.5 GHz. The hardware requirements are not very demanding making it straightforward to implement. Such an RLA may have applications going beyond muon acceleration: in medical isotope production, radiation cancer therapy and homeland security.

  13. Electrical and thermal finite element modeling of arc faults in photovoltaic bypass diodes.

    Energy Technology Data Exchange (ETDEWEB)

    Bower, Ward Isaac; Quintana, Michael A.; Johnson, Jay

    2012-01-01

    Arc faults in photovoltaic (PV) modules have caused multiple rooftop fires. The arc generates a high-temperature plasma that ignites surrounding materials and subsequently spreads the fire to the building structure. While there are many possible locations in PV systems and PV modules where arcs could initiate, bypass diodes have been suspected of triggering arc faults in some modules. In order to understand the electrical and thermal phenomena associated with these events, a finite element model of a busbar and diode was created. Thermoelectrical simulations found Joule and internal diode heating from normal operation would not normally cause bypass diode or solder failures. However, if corrosion increased the contact resistance in the solder connection between the busbar and the diode leads, enough voltage potentially would be established to arc across micron-scale electrode gaps. Lastly, an analytical arc radiation model based on observed data was employed to predicted polymer ignition times. The model predicted polymer materials in the adjacent area of the diode and junction box ignite in less than 0.1 seconds.

  14. ATLAS DDM integration in ARC

    DEFF Research Database (Denmark)

    Behrmann, Gerd; Cameron, David; Ellert, Mattias;

    2008-01-01

    The Nordic Data Grid Facility (NDGF) consists of Grid resources running ARC middleware in Denmark, Finland, Norway and Sweden. These resources serve many virtual organisations and contribute a large fraction of total worldwide resources for the ATLAS experiment, whose data is distributed and mana......The Nordic Data Grid Facility (NDGF) consists of Grid resources running ARC middleware in Denmark, Finland, Norway and Sweden. These resources serve many virtual organisations and contribute a large fraction of total worldwide resources for the ATLAS experiment, whose data is distributed...... and managed by the DQ2 software. Managing ATLAS data within NDGF and between NDGF and other Grids used by ATLAS (the Enabling Grids for E-sciencE Grid and the Open Science Grid) presents a unique challenge for several reasons. Firstly, the entry point for data, the Tier 1 centre, is physically distributed...... outside the worker node environment. Also, the service used for cataloging the location of data files is different from otherGrids but must still be useable by DQ2 and ATLAS users to locate data within NDGF. This paper presents in detail how we solve these issues to allow seamless access worldwide to data...

  15. Detecting stellar-wind bubbles through infrared arcs in H ii regions

    Science.gov (United States)

    Mackey, Jonathan; Haworth, Thomas J.; Gvaramadze, Vasilii V.; Mohamed, Shazrene; Langer, Norbert; Harries, Tim J.

    2016-02-01

    Mid-infrared arcs of dust emission are often seen near ionizing stars within H ii regions. A possible explanations for these arcs is that they could show the outer edges of asymmetric stellar wind bubbles. We use two-dimensional, radiation-hydrodynamics simulations of wind bubbles within H ii regions around individual stars to predict the infrared emission properties of the dust within the H ii region. We assume that dust and gas are dynamically well-coupled and that dust properties (composition, size distribution) are the same in the H ii region as outside it, and that the wind bubble contains no dust. We post-process the simulations to make synthetic intensity maps at infrared wavebands using the torus code. We find that the outer edge of a wind bubble emits brightly at 24 μm through starlight absorbed by dust grains and re-radiated thermally in the infrared. This produces a bright arc of emission for slowly moving stars that have asymmetric wind bubbles, even for cases where there is no bow shock or any corresponding feature in tracers of gas emission. The 24 μm intensity decreases exponentially from the arc with increasing distance from the star because the dust temperature decreases with distance. The size distribution and composition of the dust grains has quantitative but not qualitative effects on our results. Despite the simplifications of our model, we find good qualitative agreement with observations of the H ii region RCW 120, and can provide physical explanations for any quantitative differences. Our model produces an infrared arc with the same shape and size as the arc around CD -38°11636 in RCW 120, and with comparable brightness. This suggests that infrared arcs around O stars in H ii regions may be revealing the extent of stellar wind bubbles, although we have not excluded other explanations.

  16. Sensoring fusion data from the optic and acoustic emissions of electric arcs in the GMAW-S process for welding quality assessment.

    Science.gov (United States)

    Alfaro, Sadek Crisóstomo Absi; Cayo, Eber Huanca

    2012-01-01

    The present study shows the relationship between welding quality and optical-acoustic emissions from electric arcs, during welding runs, in the GMAW-S process. Bead on plate welding tests was carried out with pre-set parameters chosen from manufacturing standards. During the welding runs interferences were induced on the welding path using paint, grease or gas faults. In each welding run arc voltage, welding current, infrared and acoustic emission values were acquired and parameters such as arc power, acoustic peaks rate and infrared radiation rate computed. Data fusion algorithms were developed by assessing known welding quality parameters from arc emissions. These algorithms have showed better responses when they are based on more than just one sensor. Finally, it was concluded that there is a close relation between arc emissions and quality in welding and it can be measured from arc emissions sensing and data fusion algorithms.

  17. Sensoring Fusion Data from the Optic and Acoustic Emissions of Electric Arcs in the GMAW-S Process for Welding Quality Assessment

    Directory of Open Access Journals (Sweden)

    Eber Huanca Cayo

    2012-05-01

    Full Text Available The present study shows the relationship between welding quality and optical-acoustic emissions from electric arcs, during welding runs, in the GMAW-S process. Bead on plate welding tests was carried out with pre-set parameters chosen from manufacturing standards. During the welding runs interferences were induced on the welding path using paint, grease or gas faults. In each welding run arc voltage, welding current, infrared and acoustic emission values were acquired and parameters such as arc power, acoustic peaks rate and infrared radiation rate computed. Data fusion algorithms were developed by assessing known welding quality parameters from arc emissions. These algorithms have showed better responses when they are based on more than just one sensor. Finally, it was concluded that there is a close relation between arc emissions and quality in welding and it can be measured from arc emissions sensing and data fusion algorithms.

  18. SU-E-J-81: Interplay Effect in Non-Gated Dynamic Treatment Delivery of a Lung Phantom with Simulated Respiratory Motion

    Energy Technology Data Exchange (ETDEWEB)

    Desai, V; Fagerstrom, J; Bayliss, A; Kissick, M [University of Wisconsin, Madison, WI (United States)

    2014-06-01

    Purpose: To quantify the interplay effect in non-gated VMAT external beam delivery using realistic, clinically relevant 3D motion in an anthropomorphic lung phantom, and to determine if adding margins is sufficient to account for motion or if gating is required in all cases. Methods: A 4D motion stage was used to move a Virtual Water (VW) lung target containing a piece of radiochromic EBT3 film in an anthropomorphic chest phantom. A five-arc stereotactic body radiation therapy (SBRT) treatment was planned using a CT scan of the phantom in its stationary position, using planning parameters chosen to push the optimizer to achieve a highly-modulated plan. Two scenarios were delivered using a Varian TrueBeam: the first was delivered with the phantom and target both stationary and the second was delivered with the phantom stationary but the target moving in a realistic, irregular 3D elliptical pattern. A single piece of 4×4 cm{sup 2} film was used per fraction, located in the central coronal plane of the target. Film was calibrated on a 6 MV beam with dose values from 0.20 to 20 Gy. Results: Preliminary test films were analyzed in ImageJ and MatLab software. Dose maps were calculated on a central region of interest (ROI) delineated on both the motion-induced and stationary films. Both static and dynamic film dose maps agreed with planning values within acceptable uncertainty. Conclusion: Including a large number of arcs in a clinically realistic SBRT treatment could reduce the effect of motion interplay due to averaging. Because all clinics do not employ multiple arcs for SBRT lung treatments, it is still important to consider the effects of motion on treatment delivery. Further analysis on the treatment films, as well as a broader investigation other planning parameters, will be conducted.

  19. Optical diagnostics of a gliding arc

    DEFF Research Database (Denmark)

    Sun, Z.W.; Zhu, J.J.; Li, Z.S.;

    2013-01-01

    Dynamic processes in a gliding arc plasma generated between two diverging electrodes in ambient air driven by 31.25 kHz AC voltage were investigated using spatially and temporally resolved optical techniques. The life cycles of the gliding arc were tracked in fast movies using a high-speed camera...

  20. Modeling and Simulation of Low Voltage Arcs

    NARCIS (Netherlands)

    Ghezzi, L.; Balestrero, A.

    2010-01-01

    Modeling and Simulation of Low Voltage Arcs is an attempt to improve the physical understanding, mathematical modeling and numerical simulation of the electric arcs that are found during current interruptions in low voltage circuit breakers. An empirical description is gained by refined electrical m

  1. Implementing RapidArc into clinical routine

    DEFF Research Database (Denmark)

    Van Esch, Ann; Huyskens, Dominique P; Behrens, Claus F;

    2011-01-01

    With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto...

  2. The structure and singularities of arc complexes

    DEFF Research Database (Denmark)

    Penner, Robert

    A classical combinatorial fact is that the simplicial complex consisting of disjointly embedded chords in a convex planar polygon is a sphere. For any surface F with non-empty boundary, there is an analogous complex Arc(F) consisting of suitable equivalence classes of arcs in F connecting its bou...

  3. Characterization of Micro-arc Oxidized Titanium

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The observation of the sparkling discharges during the micro-arc oxidation process in KOH aqueous electrolyte was achieved. The change of surface morphology was progressively observed and a plausible pore formation mechanism is proposed. Cell proliferation and ALP activity of micro-arc oxidized titanium was evaluated by human body derived osteoblasts and slightly better than those of blasted surface.

  4. The next-generation ARC middleware

    DEFF Research Database (Denmark)

    Appleton, O.; Cameron, D.; Cernak, J.

    2010-01-01

    The Advanced Resource Connector (ARC) is a light-weight, non-intrusive, simple yet powerful Grid middleware capable of connecting highly heterogeneous computing and storage resources. ARC aims at providing general purpose, flexible, collaborative computing environments suitable for a range of use...

  5. Fast approximate delivery of fluence maps: the VMAT case

    CERN Document Server

    Balvert, Marleen

    2016-01-01

    In this article we provide a method to generate the trade-off between delivery time and fluence map matching quality for volumetric modulated arc therapy (VMAT). At the heart of our method lies a mathematical programming model that, for a given duration of delivery, optimizes leaf trajectories and dose rates such that the desired fluence map is reproduced as well as possible. This model was presented for the single map case in a companion paper (Fast approximate delivery of fluence maps: the single map case). The resulting large-scale, non-convex optimization problem was solved using a heuristic approach. The single-map approach cannot directly be applied to the full arc case due to the large increase in model size, the issue of allocating delivery times to each of the arc segments, and the fact that the ending leaf positions for one map will be the starting leaf positions for the next map. In this article the method proposed in \\cite{dm1} is extended to solve the full map treatment planning problem. We test ...

  6. Application of a new dosimetry formalism to volumetric modulated arc therapy (VMAT).

    Science.gov (United States)

    Rosser, Karen E; Bedford, James L

    2009-12-07

    Volumetric modulated arc therapy (VMAT) offers a challenge to classical dosimetry protocols as the beams are dynamic in orientation and aperture shape and may include small apertures. The aim of this paper is to apply a formalism to VMAT beams that has recently been published by the International Atomic Energy Agency (IAEA) working party to improve the dosimetry for small and non-standard fields. We investigated three possible fields and assessed their suitability as plan class specific reference (pcsr) fields. The factors in the new dosimetry formalism were investigated: the conversion of dose to water from the conventional reference field to the pcsr and then from the pcsr to a treatment plan, using a PTW semiflex chamber, two Farmer chambers and an electron diode. Finally, the dose was compared for Alanine, the new formalism and calculated using Pinnacle(3) (Philips Radiation Oncology Systems) for two typical clinical VMAT beams. Correction factors between the reference field and the pcsr determined with Alanine range from 0.1% to 2.3% for the three pcsr fields. Dose to water measured using the calibrated ionization chambers is less than 2% different to the dose calculated by Pinnacle(3). VMAT planning and delivery procedures have been successfully implemented and a new dosimetry protocol has been investigated for this new technique. Calibration factors for pcsr fields are found to be up to 2.3% different when using the new formalism, compared to using a standard dosimetry protocol. Using the calibration factors determined in the pcsr fields, the ionization chambers and electron diode agree to within 1% with Alanine dosimetry for two clinical VMAT plans. Good agreements between calculations and measurements are found for these two plans when the new formalism is used.

  7. Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy

    Science.gov (United States)

    Pommer, Tobias; Falk, Marianne; Poulsen, Per R.; Keall, Paul J.; O’Brien, Ricky T.; Petersen, Peter Meidahl; Rosenschöld, Per Munck af

    2013-01-01

    This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode arrays was used for dosimetry. A motion platform reproduced six patient-derived prostate motion traces, with the average displacement ranging from 1.0 to 8.9 mm during the first 75 seconds. A research DMLC tracking system was used for real-time motion compensation with optical monitoring for position input. The gamma index was used for evaluation, with measurements with a static phantom or the planned dose as reference, using 2% and 2 mm gamma criteria. The average pass rate with DMLC tracking was 99.9% (range 98.7–100%, measurement as reference), whereas the pass rate for untracked deliveries decreased distinctly as the average displacement increased, with an average pass rate of 61.3% (range 32.7–99.3%). Dose-volume histograms showed that DMLC tracking maintained the planned dose distributions in the presence of motion whereas traces with > 3 mm average displacement caused clear plan degradation for untracked deliveries. The dose to the rectum and bladder had an evident dependence on the motion direction and amplitude for untracked deliveries, and the dose to the rectum was slightly increased for IPL boosted plans compared to conventional plans for anterior motion with large amplitude. In conclusion, optimization using a leaf

  8. Numerical Study on Arc Plasma Behavior During Arc Commutation Process in Direct Current Circuit Breaker

    Institute of Scientific and Technical Information of China (English)

    杨飞; 马瑞光; 吴翊; 孙昊; 纽春萍; 荣命哲

    2012-01-01

    This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker (DCCB) contact system. A three-dimensional magneto-hydrodynamic (MHD) model of air arc plasma in the contact system of a DCCB is developed, based on commercial software FLUENT. Coupled electromagnetic and gas dynamic interactions are considered as usual, and a thin layer of nonlinear electrical resistance elements is used to represent the voltage drop of plasma sheath and the formation of new arc root. The distributions of pressure, temperature, gas flow and current density of arc plasma in arc region are calculated. The simulation results indicate that the pressure distribution related to the contact system has a strong effect on the arc commutation process, arising from the change of electrical conductivity in the arc root region. In DCCB contact system, the pressure of arc root region will be concentrated and higher if the space above the moving contact is enclosed, which is not good for arc root commutation. However, when the region is opened, the pressure distribution would be lower and more evenly, which is favorable for the arc root commutation.

  9. Gliding arc triggered microwave plasma arc at atmospheric pressure for coal gasification application

    Science.gov (United States)

    Jain, Vishal; Visani, A.; Patil, C.; Patel, B. K.; Sharma, P. K.; John, P. I.; Nema, S. K.

    2014-08-01

    Plasma torch is device that efficiently converts electrical energy in to thermal energy for various high temperature applications. The conventional plasma torch comprises of consumable electrodes namely anode and cathode electrodes. The replacement of these electrodes is a complex process owing to its cooling and process shut down requirements. However, microwave plasma arc is electrode-less plasma arc system that is an alternative method to conventional arc technology for generating plasma arc. In this technique, microwave power is efficiently coupled to generate plasma arc by using the property of polar molecule to absorb microwave power. The absorption of microwave power is in form of losses due to intermolecular friction and high collisions between the molecules. This is an efficient method because all microwave power can be absorbed by plasma arc. The main feature of microwave plasma arc is its large uniform high temperature column which is not possible with conventional arc discharge methods. Such type of plasma discharge is very useful in applications where sufficient residence time for treat materials is required. Microwave arc does not require any consumable electrodes and hence, it can be operated continuously that makes it very useful for hazardous effluent treatment applications. Further, microwave cannot ionize neutral particles at atmospheric pressure and hence, a gliding arc is initiated between two thin electrodes in the cavity by applying very low power high voltage (3kV) AC source. In this report, the method for generating microwave arc of 1kW power using commercial microwave oven is elaborated.

  10. Investigation of Metal Puff Z pinch Based on Multichannel Vacuum Arcs

    Science.gov (United States)

    Rousskikh, A. G.; Oreshkin, V. I.; Zhigalin, A. S.; Chaikovsky, S. A.; Baksht, R. B.; Mitrofanov, K. N.

    2015-11-01

    The performance of a metal double puff Z-pinch system has been studied experimentally. In this type of system, the outer and inner cylindrical shells were produced by ten plasma guns. Each gun initiates a vacuum arc operating between aluminum electrodes. The net current of the guns was 80 kA. The arc-produced plasma shells were compressed by using a 450-kA, 450-ns driver, and as a result, a plasma column 0.2 cm in diameter was formed. The power of the Al K-line radiation emitted by the plasma for 7 ns was 800 MW/cm.

  11. Arc burst pattern analysis fault detection system

    Science.gov (United States)

    Russell, B. Don (Inventor); Aucoin, B. Michael (Inventor); Benner, Carl L. (Inventor)

    1997-01-01

    A method and apparatus are provided for detecting an arcing fault on a power line carrying a load current. Parameters indicative of power flow and possible fault events on the line, such as voltage and load current, are monitored and analyzed for an arc burst pattern exhibited by arcing faults in a power system. These arcing faults are detected by identifying bursts of each half-cycle of the fundamental current. Bursts occurring at or near a voltage peak indicate arcing on that phase. Once a faulted phase line is identified, a comparison of the current and voltage reveals whether the fault is located in a downstream direction of power flow toward customers, or upstream toward a generation station. If the fault is located downstream, the line is de-energized, and if located upstream, the line may remain energized to prevent unnecessary power outages.

  12. Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique

    Directory of Open Access Journals (Sweden)

    Zhang Geoffrey G

    2011-11-01

    Full Text Available Abstract Purpose Frequently, three-dimensional (3D conformal beams are used in lung cancer stereotactic body radiotherapy (SBRT. Recently, volumetric modulated arc therapy (VMAT was introduced as a new treatment modality. VMAT techniques shorten delivery time, reducing the possibility of intrafraction target motion. However dose distributions can be quite different from standard 3D therapy. This study quantifies those differences, with focus on VMAT plans using unflattened photon beams. Methods A total of 15 lung cancer patients previously treated with 3D or VMAT SBRT were randomly selected. For each patient, non-coplanar 3D, coplanar and non-coplanar VMAT and flattening filter free VMAT (FFF-VMAT plans were generated to meet the same objectives with 50 Gy covering 95% of the PTV. Two dynamic arcs were used in each VMAT plan. The couch was set at ± 5° to the 0° straight position for the two non-coplanar arcs. Pinnacle version 9.0 (Philips Radiation Oncology, Fitchburg WI treatment planning system with VMAT capabilities was used. We analyzed the conformity index (CI, which is the ratio of the total volume receiving at least the prescription dose to the target volume receiving at least the prescription dose; the conformity number (CN which is the ratio of the target coverage to CI; and the gradient index (GI which is the ratio of the volume of 50% of the prescription isodose to the volume of the prescription isodose; as well as the V20, V5, and mean lung dose (MLD. Paired non-parametric analysis of variance tests with post-tests were performed to examine the statistical significance of the differences of the dosimetric indices. Results Dosimetric indices CI, CN and MLD all show statistically significant improvement for all studied VMAT techniques compared with 3D plans (p Conclusion Besides the advantage of faster delivery times, VMAT plans demonstrated better conformity to target, sharper dose fall-off in normal tissues and lower dose to

  13. INTERPOLATION WITH RESTRICTED ARC LENGTH

    Institute of Scientific and Technical Information of China (English)

    Petar Petrov

    2003-01-01

    For given data (ti,yi), I= 0,1,…,n,0 = t0 <t1 <…<tn = 1we study constrained interpolation problem of Favard type inf{‖f"‖∞|f∈W2∞[0,1],f(ti)=yi,i=0,…,n,l(f;[0,1])≤l0}, wherel(f";[0,1])=∫1 0 / 1+f'2(x)dx is the arc length off in [0,1]. We prove the existence of a solution f* of the above problem, that is a quadratic spline with a second derivative f"* , which coincides with one of the constants - ‖f"*‖∞,0,‖f"*‖∞ between every two consecutive knots. Thus, we extend a result ofKarlin concerning Favard problem, to the case of restricted length interpolation.

  14. Computer simulation to arc spraying

    Institute of Scientific and Technical Information of China (English)

    梁志芳; 李午申; 王迎娜

    2004-01-01

    The arc spraying process is divided into two stages: the first stage is atomization-spraying stream (ASS) and the second one is spraying deposition (SD). Then study status is described of both stages' physical model and corresponding controlling-equation. Based on the analysis of study status, the conclusion as follows is got. The heat and mass transfer models with two or three dimensions in ASS stage should be established to far deeply analyses the dynamical and thermal behavior of the overheat droplet. The statistics law of overheated droplets should be further studied by connecting simulation with experiments. More proper validation experiments should be designed for flattening simulation to modify the models in SD stage.

  15. ATLAS DDM integration in ARC

    DEFF Research Database (Denmark)

    Behrmann, Gerd; Cameron, David; Ellert, Mattias;

    The Nordic Data Grid Facility (NDGF) consists of Grid resources running ARC middleware in Scandinavia and other countries. These resources serve many virtual organisations and contribute a large fraction of total worldwide resources for the ATLAS experiment, whose data is distributed and managed...... by the DQ2 software. Managing ATLAS data within NDGF and between NDGF and other Grids used by ATLAS (the LHC Computing Grid and the Open Science Grid) presents a unique challenge for several reasons. Firstly, the entry point for data, the Tier 1 centre, is physically distributed among heterogeneous...... environment. Also, the service used for cataloging the location of data files is different from other Grids but must still be useable by DQ2 and ATLAS users to locate data within NDGF. This paper presents in detail how we solve these issues to allow seamless access worldwide to data within NDGF....

  16. Characteristics of acoustic-controlled arc in ultrasonic wave-assisted arc%超声复合电弧声调控特性研究

    Institute of Scientific and Technical Information of China (English)

    谢伟峰; 范成磊; 杨春利; 林三宝; 张玉岐

    2015-01-01

    As a new welding method, ultrasound has been successfully introduced into the pool during ultrasonic wave-assisted arc welding process. However, the interaction mechanism between the ultrasound and the arc plasma is not clear, thus preventing the new technique from engineering applications. In this paper, the characteristic of arc regulation by external ultrasonic field is investigated based on the experimental data and the corresponding theory. In order to figure out the characteristics of arc, the arc images obtained by high-speed camera are processed. Compared with the conventional welding arc, ultrasonic wave-assisted arc is more contracted and becomes brighter, the high-temperature region in an arc column greatly expands, and there are internal particle agglomerations shaking up and down at a constant frequency. The arc shape varies with ultrasound excitation current and the height of ultrasonic radiator. In the vicinity of the resonance point, the straight-degree of the arc is the strongest and the ripple frequency is also the largest. Results show that the purpose of using external ultrasound field to regulate the thermal plasma has basically achieved. Analyzing the acoustic pressure wave equation for the neutral component shows that the spatial distribution of acoustic wave can be generated in the arc and its intensity is proportional to the local amplitude of acoustic waves. Acoustic pressure field can be calculated based on the dependence of the electron temperature and density on time and space. In addition to the action of acoustic field within the arc, the arc plasma is also controlled by the acoustic field structure. A two-cylinder model incorporating boundary element method is developed, establishing a relationship between the binding capability and the geometric parameters of an ultrasonic radiator with reference to wavelength. This model is successful in predicting resonant modes of the acoustic field and explaining the influences of the ultrasonic

  17. Analysis of arc emission spectra of stainless steel electric arc furnace slag affected by fluctuating arc voltage.

    Science.gov (United States)

    Aula, Matti; Mäkinen, Ari; Fabritius, Timo

    2014-01-01

    Control of chromium oxidation in the electric arc furnace (EAF) is a significant problem in stainless steel production due to variations of the chemical compositions in the EAF charge. One potential method to control chromium oxidation is to analyze the emission spectrum of the electric arc in order to find indicators of rising chromium content in slag. The purpose of this study was to determine if slag composition can be gained by utilizing electric arc emission spectra in the laboratory environment, despite electric arc voltage fluctuations and varying slag composition. The purpose of inducing voltage fluctuation was to simulate changes in the industrial EAF process. The slag samples were obtained from Outokumpu Stainless Oy Tornio Works, and three different arc currents were used. The correlation analysis showed that the emission spectra offer numerous peak ratios with high correlations to the X-ray fluorescence-measured slag CrO(x)/FeO(x) and MnO/SiO2 ratios. These ratios are useful in determining if the reduction agents have been depleted in the EAF. The results suggest that analysis of laboratory-scale electric arc emission spectra is suitable for indicating the high CrO(x) or MnO content of the slag despite the arc fluctuations. Reliable analysis of other slag components was not successful.

  18. Development of a fiber-optic laser delivery system capable of delivering 213 and 266 nm pulsed Nd:YAG laser radiation for tissue ablation in a fluid environment.

    Science.gov (United States)

    Miller, Joe; Yu, Xiao-Bo; Yu, Paula K; Cringle, Stephen J; Yu, Dao-Yi

    2011-02-20

    Ultraviolet (UV) lasers have the capability to precisely remove tissue via ablation; however, due to strong absorption of the applicable portion the UV spectrum, their surgical use is currently limited to extraocular applications at the air/tissue boundary. Here we report the development and characterization of a fiber-optic laser delivery system capable of outputting high-fluence UV laser pulses to internal tissue surfaces. The system has been developed with a view to intraocular surgical applications and has been demonstrated to ablate ocular tissue at the fluid/tissue boundary. The fifth (213 nm) and fourth(266 nm) harmonics of a Nd:YAG laser were launched into optical fibers using a hollow glass taper to concentrate the beam. Standard and modified silica/silica optical fibers were used, all commercially available. The available energy and fluence as a function of optical fiber length was evaluated and maximized. The maximum fluence available to ablate tissue was affected by the wavelength dependence of the fiber transmission; this maximum fluence was greater for 266 nm pulses (8.4 J/cm2) than for 213 nm pulses (1.4 J/cm2). The type of silica/silica optical fiber used did not affect the transmission efficiency of 266 nm pulses, but transmission of 213 nm pulses was significantly greater through modified silica/silica optical fiber. The optical fiber transmission efficiency of 213 nm pulses decreased as a function of number of pulses transmitted, whereas the transmission efficiency of 266 nm radiation was unchanged. Single pulses have been used to ablate fresh porcine ocular tissue. In summary, we report a method for delivering the fifth (213 nm) and fourth (266 nm) harmonics of a Nd:YAG laser to the surface of immersed tissue, the reliability and stability of the system has been characterized, and proof of concept via tissue ablation of porcine ocular tissue demonstrates the potential for the intraocular surgical application of this

  19. Validation of Pinnacle treatment planning system for use with Novalis delivery unit.

    Science.gov (United States)

    Faygelman, Vladimir; Hunt, Dylan; Walker, Luke; Mueller, Richard; Demarco, Mary Lou; Dilling, Thomas; Stevens, Craig; Zhang, Geoffrey

    2010-06-15

    For an institution that already owns the licenses, it is economically advantageous and technically feasible to use Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI) with the BrainLab Novalis delivery system (BrainLAB A.G., Heimstetten, Germany). This takes advantage of the improved accuracy of the convolution algorithm in the presence of heterogeneities compared with the pencil beam calculation, which is particularly significant for lung SBRT treatments. The reference patient positioning DRRs still have to be generated by the BrainLab software from the CT images and isocenter coordinates transferred from Pinnacle. We validated this process with the end-to-end hidden target test, which showed an isocenter positioning error within one standard deviation from the previously established mean value. The Novalis treatment table attenuation is substantial (up to 6.2% for a beam directed straight up and up to 8.4% for oblique incidence) and has to be accounted for in calculations. A simple single-contour treatment table model was developed, resulting in mean differences between the measured and calculated attenuation factors of 0.0%-0.2%, depending on the field size. The maximum difference for a single incidence angle is 1.1%. The BrainLab micro-MLC (mMLC) leaf tip, although not geometrically round, can be represented in Pinnacle by an arch with satisfactory dosimetric accuracy. Subsequently, step-and-shoot (direct machine parameter optimization) IMRT dosimetric agreement is excellent. VMAT (called "SmartArc" in Pinnacle) treatments with constant gantry speed and dose rate are feasible without any modifications to the accelerator. Due to the 3 mm-wide mMLC leaves, the use of a 2 mm calculation grid is recommended. When dual arcs are used for the more complex cases, the overall dosimetric agreement for the SmartArc plans compares favorably with the previously reported results for other implementations of VMAT: gamma(3%,3mm) for absolute dose obtained with the

  20. Towards a theory for Neptune's arc rings

    Science.gov (United States)

    Goldreich, P.; Tremaine, S.; Borderies, N.

    1986-01-01

    It is proposed that the incomplete rings of Neptune consist of a number of short arcs centered on the corotation resonances of a single satellite. The satellite must have a radius of the order of 100 km or more and move on an inclined orbit. Corotation resonances are located at potential maxima. Thus, mechanical energy dissipated by interparticle collisions must be continually replenished to prevent the arcs from spreading. It is shown that each corotation resonance is associated with a nearby Lindblad resonance, which excites the ring particles' orbital eccentricity, thus supplying the energy required to maintain the arc. The ultimate energy reservoir is the satellite's orbital energy. Therefore, interaction with the arcs damps the satellite's orbital inclination. The self-gravity of the arcs limits their contraction and enforces a relation between arc length and mass. The estimated arc masses are so small, of the order of 10 to the 16th g, that the satellite's orbital inclination suffers negligible decay over the age of the solar system. The inferred surface mass densities are comparable to those found in the major rings of Saturn and Uranus.

  1. Contribution For Arc Temperature Affected By Current Increment Ratio At Peak Current In Pulsed Arc

    Science.gov (United States)

    Kano, Ryota; Mitubori, Hironori; Iwao, Toru

    2015-11-01

    Tungsten Inert Gas (TIG) Welding is one of the high quality welding. However, parameters of the pulsed arc welding are many and complicated. if the welding parameters are not appropriate, the welding pool shape becomes wide and shallow.the convection of driving force contributes to the welding pool shape. However, in the case of changing current waveform as the pulse high frequency TIG welding, the arc temperature does not follow the change of the current. Other result of the calculation, in particular, the arc temperature at the reaching time of peak current is based on these considerations. Thus, the accurate measurement of the temperature at the time is required. Therefore, the objective of this research is the elucidation of contribution for arc temperature affected by current increment ratio at peak current in pulsed arc. It should obtain a detail knowledge of the welding model in pulsed arc. The temperature in the case of increment of the peak current from the base current is measured by using spectroscopy. As a result, when the arc current increases from 100 A to 150 A at 120 ms, the transient response of the temperature didn't occur during increasing current. Thus, during the current rise, it has been verified by measuring. Therefore, the contribution for arc temperature affected by current increment ratio at peak current in pulsed arc was elucidated in order to obtain more knowledge of welding model of pulsed arc.

  2. Reconstruction of Late Cretaceous Magmatic Arcs in the Northern Andes: Single Versus Multiple Arc Systems

    Science.gov (United States)

    Cardona, A.; Jaramillo, J. S.; Leon, S.; Hincapie, S.; Mejia, D.; Patino, A. M.; Vanegas, J.; Zapata, S.; Valencia, V.; Jimenez, G.; Monsalve, G.

    2014-12-01

    Although magmatic rocks are major tracers of the geological evolution of convergent margins, pre-collisional events such as subduction erosion, collisional thrusting or late collisional strike slip segmentation may difficult the recognizing of multiple arc systems and therefore the existence of paleogeographic scenarios with multiple subduction systems. New field, U-Pb geochronology and whole rock geochemistry constraints from the northwestern segment of the Central Cordillera in the states of Antioquia and Caldas (Colombia) are used to understand the nature of the Late Cretaceous arc magmatism and evaluate the existence of single or multiple Pacific and Caribbean arc systems in the growth of the Northwestern Andes. The new results integrated with additional field and published information is used to suggest the existence of at least three different magmatic arcs. (1) An Eastern Continental arc built within a well defined Permian to Triassic continental crust that record a protracted 90-70 Ma magmatic evolution, (2) a 90-80 arc formed within attenuated continental crust and associated oceanic crust, (3) 90-88 Ma arc formed over a Late Cretaceous plateau crust. The eastern arcs were formed as part of double eastern vergent subduction system, where the most outboard arc represent a fringing arc formed over detached fragments of continental crust, whereas the easternmost continental arc growth by the closure an subduction of and older and broad Triassic to Early Jurassic back-arc ocean. Its closure also end up in ophiolite emplacement. The third allochtonous oceanic arc was formed over the Caribbean plateau crust and was accreted to the continental margin in the Late Cretaceous. Ongoing paleomagnetic, deformational, gravimetric and basin analysis will be integrate to test this model and understand the complex Late Cretaceous tectonic evolution of the Northern Andes.

  3. The Global Array of Primitve Arc Melts

    Science.gov (United States)

    Schmidt, M. W.; Jagoutz, O. E.

    2015-12-01

    A longstanding question concerns the nature of the melts forming in the subarc mantle and giving rise to arc magmatism. The global array of primitive arc melts (1180 volcanic rocks in 25 arcs extracted from the georoc database, calculated to be in equilibrium with mantle olivine) yields five principal melt types: calc-alkaline basalts and high-Mg andesites, tholeiitic basalts and high-Mg andesites, and shoshonitic or alkaline arc melts; many arcs have more than one type. Primitive calc-alkaline basalts occur in 11 arcs but most strikingly, 8 continental arcs (incl. Aleutians, Cascades, Japan, Mexico, Kamtschatka) have a continuous range of calc-alkaline basalts to high-Mg andesites with mostly 48-58 wt% SiO2. In each arc, these are spatially congruent, trace element patterns overlap, and major elements form a continuum. Their Ca-Mg-Si systematics suggests saturation in olivine+opx+cpx. We hence interpret the large majority of high-Mg andesites as derived from primitive calc-alkaline basalts through fractionation and reaction in the shallower mantle. Removal of anhydrous mantle phases at lower pressures increases SiO2 and H2O-contents while Mg# and Ni remain buffered to mantle values. Primitive tholeiitic basalts (Cascades, Kermadec, Marianas, Izu-Bonin, Japan, Palau, Sunda) have a much lesser subduction signal (e.g. in LILE) than the calc-alkaline suite. These tholeiites have been interpreted to form through decompression melting, but also characterize young intraoceanic arcs. In the two continental arcs with both tholeiitic and calc-alkaline primitive basalts (clearly distinct in trace patterns), there is no clear spatial segregation (Casacades, Japan). Three intraoceanic arcs (Marianas, Izu-Bonin, Tonga) have primitive tholeiitic, highly depleted high-Mg andesites (boninites) with HFSE and HREE slightly above primitive mantle values. These deviate in majors from the array formed by the basalts and calc-alkaline andesites suggesting that only these formed from a

  4. Formation of the G-ring arc

    Science.gov (United States)

    Araujo, N. C. S.; Vieira Neto, E.; Foryta, D. W.

    2016-09-01

    Since 2004, the images obtained by the Cassini spacecraft's on-board cameras have revealed the existence of several small satellites in the Saturn system. Some of these small satellites are embedded in arcs of particles. While these satellites and their arcs are known to be in corotation resonances with Mimas, their origin remains unknown. This work investigates one possible process for capturing bodies into a corotation resonance, which involves increasing the eccentricity of a perturbing body. Therefore, through numerical simulations and analytical studies, we show a scenario in which the excitation of Mimas's eccentricity could capture particles in a corotation resonance. This is a possible explanation for the origin of the arcs.

  5. Formation of the G-ring arc

    CERN Document Server

    Araujo, N C S; Foryta, D W

    2016-01-01

    Since 2004, the images obtained by Cassini spacecraft's on-board cameras have revealed the existence of several small satellites in the Saturn system. Some of these small satellites are embedded in arcs of particles. While these satellites and their arcs are known to be in corotation resonances with Mimas, their origin remains unknown. This work investigates one possible process for capturing bodies into a corotation resonance, which involves raising the eccentricity of a perturbing body. Therefore, through numerical simulations and analytical studies, we show a scenario that the excitation of Mimas' eccentricity could capture particles in a corotation resonance and given a possible explanation for the origin for the arcs.

  6. Cathodic Vacuum Arc Plasma of Thallium

    OpenAIRE

    Yushkov, Georgy Yu.; Anders, Andre

    2006-01-01

    Thallium arc plasma was investigated in a vacuum arc ion source. As expected from previous consideration of cathode materials in the Periodic Table of the Elements, thallium plasma shows lead-like behavior. Its mean ion charge state exceeds 2.0 immediately after arc triggering, reaches the predicted 1.60 and 1.45 after about 100 microsec and 150 microsec, respectively. The most likely ion velocity is initially 8000 m/s and decays to 6500 m/s and 6200 m/s after 100 microsec and 150 micros...

  7. Linear volcanic segments in the Sunda Arc, Indonesia: Implications for arc lithosphere control upon volcano distribution

    Science.gov (United States)

    Macpherson, C. G.; Pacey, A.; McCaffrey, K. J.

    2012-12-01

    The overall curvature of many subduction zones is immediately apparent and the term island arc betrays the common assumption that subduction zone magmatism occurs in curved zones. This assumption can be expressed by approximating island arcs as segments of small circles on the surface of a sphere. Such treatments predict that the location of arc volcanoes is related to their vertical separation from the slab (in fact, the depth to seismicity in the slab) and require that the primary control on the locus of magmatism lies either within the subducted slab or the mantle wedge that separates the subducted and overriding lithospheric plates. The concept of curved arcs ignores longstanding observations that magmatism in many subduction systems occurs as segments of linearly arranged volcanic centres. Further evidence for this distribution comes from the close relationship between magmatism and large scale, arc-parallel fabrics in some arcs. Similarly, exposures of deep arc crust or mantle often reveal elongation of magmatic intrusions sub-parallel to the inferred trend of the arc. The Sunda Arc forms the Indonesian islands from Sumatra to Alor and provides an important test for models of volcano distribution for several reasons. First, Sunda has hosted abundant historic volcanic activity. Second, with the notable exception of Krakatau, every volcano in the arc is subaerial from base to cone and, therefore, can be readily identified where there is a suitable extent of local mapping that can be used to ground-truth satellite imagery. Third, there are significant changes in the stress regime along the length of the arc, allowing the influence of the upper plate to be evaluated by comparison of different arc segments. Finally, much of the Sunda Arc has proved difficult to accommodate in models that try to relate volcano distribution to the depth to the subducted slab. We apply an objective line-fitting protocol; the Hough Transform, to explore the distribution of volcanoes

  8. Study on image acquisition in 3-D sensor system of arc welding pool surface shape using grating projection

    Science.gov (United States)

    Ai, Xiaopu; Liu, Nansheng; Wei, Yiqing; Hu, Xian; Wei, Sheng; Liu, Xiaorui

    2009-11-01

    Detecting 3-D information on welding pool surface shape is difficult due to the arc light interference, high temperature radiation and pool surface specular reflection. The characteristics of mirror like reflection on pool of liquid surface are studied. Besides the way to obtain clear information-rich image of the pool area is discussed under the strong arc light. Because of the strong arc light above the pool will affect the imaging of the relatively weaker laser stripes seriously, we need to choose a suitable shooting angle and shooting distance to achieve well image. According to all these factors, the optimal combination of the sensing structure parameters in theory is deduced. Based on this work, a vision detecting of arc welding pool surface topography system was putted up in our laboratory, also actual measurement was carried out to obtain more clear images of deformation laser stripes in welding pool. This will provide the three-dimensional reconstruction a strong support.

  9. Effects of arc-ultrasonic on pores distribution and tensile property in TIG welding joints of MGH956 alloy

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Qiang, E-mail: zhuqiang@ujs.edu.cn [School of Material Science and Engineering, Jiangsu University, Zhenjiang (China); Lei, Yu-cheng [School of Material Science and Engineering, Jiangsu University, Zhenjiang (China); State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin (China); Wang, Yunlong; Huang, Wei; Xiao, Bo; Ye, Yi-min [School of Material Science and Engineering, Jiangsu University, Zhenjiang (China)

    2014-12-15

    MGH956, a kind of oxide dispersion strengthened (ODS) alloy, which is considered as candidate structural material for advanced nuclear systems because of its excellent radiation resistance and high-temperature capability. However, pores in fusion welding joints seriously reduced the quality and performance of the joint and structure. Arc-ultrasonic technology was applied in this research in order to prevent pores and improve tensile strength. The results showed that the excitation current of arc-ultrasonic has great effect on the pores distribution and tensile property. When it is increased to 20 A or 30 A, few pores are in the joint and the tensile strength (about 550 MPa) is also improved. When the arc-ultrasonic frequency decreased from 60 kHz to 30 kHz, bubbles floated outside more easily, the tensile strength is increased to about 543 MPa. But arc-ultrasonic has little influence on weld joints microhardness change.

  10. Prostate treatments, 1MRT o RapidArc; Tratamiento de prostata, IMART o RapidArc?

    Energy Technology Data Exchange (ETDEWEB)

    Castro novais, J.; Ruiz Maqueda, S.; Pardo Perez, E.; Molina Lopez, M. Y.; Cerro Penalver, E.

    2015-07-01

    Techniques that modulate the dose (as IMRT or RapidArcTM) improve dose homogeneity within the target volume decreasing the dose in healthy organs. The aim of this work is to study the dosimetric differences in prostate radiotherapy treatments with IMRT and RapidArcTM. The results of the 109 patients studied show that plans to RapidArcTM have better coverage, compliance and dose gradient outside the target volume. (Author)

  11. Coagulation of carbon nanoparticles in the acoustic field in the vicinity of the arc discharge

    Science.gov (United States)

    Shneider, Mikhail

    2016-09-01

    An arc discharge produced in a background inert gase between graphite electrodes is one of the popular methods of nanoparticle synthesis. Nanoparticles and microscopic soot particles are produced in the peripheral region of arc. Intensive soot generation significantly reduces the efficiency of the arc as the technological process for production of fullerenes and other nanoparticles. Experimental studies have shown that exposure of peripheral region of the arc to intense ultrasound leads to a noticeable increase in the efficiency of the nanoparticle synthesis and reduces the soot yield (see, e.g.), because ultrasound causes coagulation of soot particles and decrease of their concentration without affecting the nanoparticles. The paper presents theoretical study of the threshold for the ultrasound intensity required for the coagulation as a function of particle sizes and charge, and background gas parameters. The charge acquired in a thermionic emission, as a result of particles heating by radiation from the arc, is calculated self-consistently. I would like to thank Dr. Yevgeny Raitses, Dr. Igor Kaganovich, and Mr. James Mitrani for their interest in this work and fruitful discussions. This work was supported by the U.S. Department of Energy, Office of Science, Basic Energy Sciences, Materials Sciences and Engineering Division.

  12. Optical emission from a small scale model electric arc furnace in 250-600 nm region.

    Science.gov (United States)

    Mäkinen, A; Niskanen, J; Tikkala, H; Aksela, H

    2013-04-01

    Optical emission spectroscopy has been for long proposed for monitoring and studying industrial steel making processes. Whereas the radiative decay of thermal excitations is always taking place in high temperatures needed in steel production, one of the most promising environment for such studies are electric arc furnaces, creating plasma in excited electronic states that relax with intense characteristic emission in the optical regime. Unfortunately, large industrial scale electric arc furnaces also present a challenging environment for optical emission studies and application of the method is not straightforward. To study the usability of optical emission spectroscopy in real electric arc furnaces, we have developed a laboratory scale DC electric arc furnace presented in this paper. With the setup, optical emission spectra of Fe, Cr, Cr2O3, Ni, SiO2, Al2O3, CaO, and MgO were recorded in the wavelength range 250-600 nm and the results were analyzed with the help of reference data. The work demonstrates that using characteristic optical emission, obtaining in situ chemical information from oscillating plasma of electric arc furnaces is indeed possible. In spite of complications, the method could possibly be applied to industrial scale steel making process in order to improve its efficiency.

  13. Seward, Alaska 3 arc-second DEM

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 3 arc-second Seward Alaska Elevation Grid provides bathymetric data in ASCII raster format of 2.67-second resolution in geographic coordinates. This grid is...

  14. Observation of gliding arc surface treatment

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Zhu, Jiajian; Ehn, A.

    2015-01-01

    . Water contact angle measurements indicate that the treatment uniformity improves significantly when the AC gliding arc is tilted to the polymer surface. Thickness reduction of the gas boundary layer, explaining the improvement of surface treatment, by the ultrasonic irradiation was directly observed......An alternating current (AC) gliding arc can be conveniently operated at atmospheric pressure and efficiently elongated into the ambient air by an air flow and thus is useful for surface modification. A high speed camera was used to capture dynamics of the AC gliding arc in the presence of polymer...... surfaces. A gap was observed between the polymer surface and the luminous region of the plasma column, indicating the existence of a gas boundary layer. The thickness of the gas boundary layer is smaller at higher gas flow-rates or with ultrasonic irradiation to the AC gliding arc and the polymer surface...

  15. Laboratory arc furnace features interchangeable hearths

    Science.gov (United States)

    Armstrong, J. L.; Kruger, O. L.

    1967-01-01

    Laboratory arc furnace using rapidly interchangeable hearths gains considerable versatility in casting so that buttons or special shaped castings can be produced. It features a sight glass for observation.

  16. Arc tracks on nanostructured surfaces after microbreakdowns

    Science.gov (United States)

    Sinelnikov, D.; Bulgadaryan, D.; Hwangbo, D.; Kajita, S.; Kolodko, D.; Kurnaev, V.; Ohno, N.

    2016-09-01

    Studying of initial steps of unipolar arc ignition process is important for reduction of probability of arcing between the plasma and the wall in thermonuclear devices. Tungsten nano-fuzz surface formed by helium plasma irradiation at high fluences and temperatures is a perfect material for arc ignition. Snowflake-like craters were detected on the fuzzy surfaces after short micro-breakdowns. Such sort of craters have not been observed before on any other metallic surfaces. These specific traces are formed due to unique properties of the fuzz structure. The nano-fuzz could be easily melted and vaporized by micro-breakdown current, due to its porosity and bad thermal conductivity, and formation of low conducting metallic vapour under the cathode spot causes discharge movement to the nearest place. Thus, even low current arc can easily move and leave traces, which could be easily observed by a secondary electron microscope.

  17. Seward, Alaska 1 arc-second DEM

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 1 arc-second Seward Alaska Elevation Grid provides bathymetric data in ASCII raster format of .89-second resolution in geographic coordinates. This grid is...

  18. Resistance Characteristics of Arc in Long Air Gap

    Institute of Scientific and Technical Information of China (English)

    YU Zhanqing; YU Junjie; ZENG Rong; CHEN He; PENG Xiang

    2013-01-01

    Arc resistance is an important parameter for characterizing long arcs in air,and its laboratory testing is of importance for accurate arc modeling of electromagnetic transient caused by short circuit fault.Therefore,we constructed an experimental system to study the characteristics of long AC arc in air.Driven by currents of 10 kA or 40 kA (root mean square value),the system produces arcs with different initial lengths of 1 m,2 m and 4 m,and the movement of the arcs are captured by a high-speed camera.After performing experiments using the system,we carried out analysis and comparisons of the arc resistance of arcs with different lengths and different currents,as well as a study of the relationship between the macro-morphology and the resistance of the arcs.Conclusions were drawn from the experimental results:the arc voltage had obvious saturation characteristics; the arc resistance increased with the increase of arc length and the decrease of current; the arcs bended or extended significantly in time and the peak arc voltage within a single cycle increased correspondingly; the arcs had voltage and current in the same phase.In the end,a formula of arc resistance based on the experiment results is derived.

  19. Palaeomagnetic constraints on the geodynamic evolution of the Gibraltar Arc

    NARCIS (Netherlands)

    Krijgsman, W.; Garces, M.

    2004-01-01

    Subduction zone roll-back was recently put forward as a convincing model to explain the geometry and evolution of the Gibraltar Arc. For other subduction-related arc systems of the Mediterranean, such as the Calabrian Arc and the Hellenic Arc, palaeomagnetic rotation data from Neogene extensional ba

  20. 49 CFR 195.226 - Welding: Arc burns.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding: Arc burns. 195.226 Section 195.226 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Construction § 195.226 Welding: Arc burns. (a) Each arc burn must be repaired. (b) An arc burn...

  1. Basins in ARC-continental collisions

    Science.gov (United States)

    Draut, Amy E.; Clift, Peter D.; Busby, Cathy; Azor, Antonio

    2012-01-01

    Arc-continent collisions occur commonly in the plate-tectonic cycle and result in rapidly formed and rapidly collapsing orogens, often spanning just 5-15 My. Growth of continental masses through arc-continent collision is widely thought to be a major process governing the structural and geochemical evolution of the continental crust over geologic time. Collisions of intra-oceanic arcs with passive continental margins (a situation in which the arc, on the upper plate, faces the continent) involve a substantially different geometry than collisions of intra-oceanic arcs with active continental margins (a situation requiring more than one convergence zone and in which the arc, on the lower plate, backs into the continent), with variable preservation potential for basins in each case. Substantial differences also occur between trench and forearc evolution in tectonically erosive versus tectonically accreting margins, both before and after collision. We examine the evolution of trenches, trench-slope basins, forearc basins, intra-arc basins, and backarc basins during arc-continent collision. The preservation potential of trench-slope basins is low; in collision they are rapidly uplifted and eroded, and at erosive margins they are progressively destroyed by subduction erosion. Post-collisional preservation of trench sediment and trench-slope basins is biased toward margins that were tectonically accreting for a substantial length of time before collision. Forearc basins in erosive margins are usually floored by strong lithosphere and may survive collision with a passive margin, sometimes continuing sedimentation throughout collision and orogeny. The low flexural rigidity of intra-arc basins makes them deep and, if preserved, potentially long records of arc and collisional tectonism. Backarc basins, in contrast, are typically subducted and their sediment either lost or preserved only as fragments in melange sequences. A substantial proportion of the sediment derived from

  2. Arcing flow phenomena; Visualisation des ecoulements en presence d'un arc de coupure

    Energy Technology Data Exchange (ETDEWEB)

    Rachard, H.; Mottet, C. [Schneider Electric, Centre de Recherches A2, 75 - Paris (France)

    2002-06-01

    Optical diagnostic techniques have been used for studying electric arcing phenomena at Schneider Electric for many years now, and are integrated in new-product development practice. Studies have so far focused on electric arc behaviour, but today we are especially interested in studying the interaction of an electric arc with its immediate environment, i.e. gaseous medium and neighbouring materials. This article starts by discussing the specificities of electric arcs in low-voltage circuit-breakers, then goes on to examine diagnostic methods for viewing the physical phenomena of interest. After setting out and analysing the results obtained, we conclude with details on planned upgrades targeting enhanced diagnostic performance. (author)

  3. Rapid magmatic processes accompany arc-continent collision: the Western Bismarck arc, Papua New Guinea

    Science.gov (United States)

    Cunningham, Heather; Gill, Jim; Turner, Simon; Caulfield, John; Edwards, Louise; Day, Simon

    2012-11-01

    New U-Th-Ra, major and trace element, and Sr-Nd-Pb isotope data are presented for young lavas from the New Britain and Western Bismarck arcs in Papua New Guinea. New Britain is an oceanic arc, whereas the latter is the site of an arc-continent collision. Building on a recent study of the Manus Basin, contrasts between the two arcs are used to evaluate the processes and timescales of magma generation accompanying arc-continent collision and possible slab detachment. All three suites share many attributes characteristic of arc lavas that can be ascribed to the addition of a regionally uniform subduction component derived from the subducting altered oceanic crust and sediment followed by dynamic melting of the modified mantle. However, the Western Bismarck arc lavas diverge from the Pb isotope mixing array formed by the New Britain and the Manus Basin lavas toward elevated 208Pb/204Pb. We interpret this to reflect a second and subsequent addition of sediment melt at crustal depth during collision. 238U and 226Ra excesses are preserved in all of the lavas and are greatest in the Western Bismarck arc. High-Mg andesites with high Sr/Y ratios in the westernmost arc are attributed to recent shallow mantle flux melting at the slab edge. Data for two historical rhyolites are also presented. Although these rhyolites formed in quite different tectonic settings and display different geochemical and isotopic compositions, both formed from mafic parents within millennia.

  4. 早期原发纵隔B细胞淋巴瘤静态IMRT和VMAT计划比较%Comparison of static intensity-modulated radiation therapy and volumetric modulated arc therapy in early-stage primary mediastinal B-cell lymphoma

    Institute of Scientific and Technical Information of China (English)

    徐利明; 刘清峰; 王清鑫; 戴建荣; 李晔雄; 康明磊; 江波; 房辉; 金晶; 王维虎; 王淑莲; 刘跃平; 宋永文

    2015-01-01

    Objective To compare target dosimetric distribution and normal tissue radiation between different static intensity⁃modulated radiation therapy ( IMRT) plans and volumetric modulated arc therapy ( VMAT) and to identify the best IMRT plan for patients with primary mediastinal B⁃cell lymphoma ( PMBCL) . Methods A total of 16 patients ( 8 males and 8 females) with early⁃stage ( Ann⁃Arbor stageⅠ) PMBCL were enrolled in this study,with doses of 45 Gy for primary gross tumor volume ( PGTV) and 40 Gy for planning target volume (PTV).Four plans were designed for each patient,consisting of static IMRT (5F⁃IMRT,7F⁃IMRT,9F⁃IMRT) and VMAT,and the target dosimetric distribution,normal tissue radiation dose,and efficiency of each plan were evaluated. The difference of dose was analyzed by analysis of variance. Results The mean conformity index ( CI) and homogeneity index ( HI) for PGTV in 5F⁃,7F⁃,9F⁃IMRT and VMAT were 1. 01 and 1. 10, 1. 01 and 1. 10, 1. 01 and 1. 10, and 1. 01 and 1. 11 ( P= 0. 963 and 0. 843) ,respectively,while these two indices for PTV were 1. 04 and 1. 22,1. 03 and 1. 19,1. 03 and 1. 17, and 1. 08 and 1. 14( P=0. 964 and 0. 969) ,respectively. The parameters of volume and dose were similar on normal tissue ( P= 0. 192⁃1. 000 ) . The treatment time and number of monitor units in 9F⁃IMRT were significantly higher than those in other static IMRT plans and VMAT ( P=0. 000,0. 000) ,and among these plans,VMAT had the lowest number of monitor units ( 13 345. 0 MU) and the shortest treatment time ( 5. 9 min) . Conclusions The target volume coverage of 7F⁃and 9F⁃IMRT is better than that of 5F⁃IMRT and VMAT.For early⁃stage PMBCL,VMAT is not superior to IMRT in terms of dosimetry,especially with a larger area of low⁃dose radiation to the breast,but it is highly efficient in practice.%目的:通过比较不同静态IMRT和VMAT计划靶区剂量分布与正常组织照射情况,以明确原发纵隔B细胞淋巴瘤( PMBCL)

  5. Study on Ceramic Cutting by Plasma Arc

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Engineering ceramics are typical difficult-to-machine materials because of high hardness and brittleness. PAC (Plasma Arc Cutting) is a very important thermal cutting process and has been successfully used in cutting stainless steel and other difficult-to-machine alloys. PAC's application in cutting ceramics, however, is still limited because the most ceramics are not good electronic conducts, and transferred plasma arc cannot be produced between cathode and work-piece. So we presented a method of plasma ...

  6. High current multicharged metal ion source using high power gyrotron heating of vacuum arc plasma.

    Science.gov (United States)

    Vodopyanov, A V; Golubev, S V; Khizhnyak, V I; Mansfeld, D A; Nikolaev, A G; Oks, E M; Savkin, K P; Vizir, A V; Yushkov, G Yu

    2008-02-01

    A high current, multi charged, metal ion source using electron heating of vacuum arc plasma by high power gyrotron radiation has been developed. The plasma is confined in a simple mirror trap with peak magnetic field in the plug up to 2.5 T, mirror ratio of 3-5, and length variable from 15 to 20 cm. Plasma formed by a cathodic vacuum arc is injected into the trap either (i) axially using a compact vacuum arc plasma gun located on axis outside the mirror trap region or (ii) radially using four plasma guns surrounding the trap at midplane. Microwave heating of the mirror-confined, vacuum arc plasma is accomplished by gyrotron microwave radiation of frequency 75 GHz, power up to 200 kW, and pulse duration up to 150 micros, leading to additional stripping of metal ions by electron impact. Pulsed beams of platinum ions with charge state up to 10+, a mean charge state over 6+, and total (all charge states) beam current of a few hundred milliamperes have been formed.

  7. Electric arc furnace models for flicker study

    Directory of Open Access Journals (Sweden)

    Catalina González Castaño

    2016-06-01

    Full Text Available Objective: The aim of this paper is to evaluate voltage fluctuations or flicker of two electric arc furnace models through comparison with real data.Method: The first proposed model is founded on the energy conservation principle, which generates a non-linear differential equation modelling the electric arc voltage – current characteristics. Voltage fluctuations are generated using a chaotic circuit that modulates the amplitude of arc voltage. The second model is based on the empirical relationship between the arc diameter or length as well as voltage and electrical current on the arc. Voltage fluctuations are considered adding a random signal in the arc length. Both models are implemented in PSCADTM.Results: The results of both models are compared with real data taken at the most critical stage of the operation of the furnace, and they show that the model based on energy conservation has a lower average mean square error in the voltages and currents 5.6 V and 1.7 kA against 27,2 V y 3.38 kA obtained with the second model.Conclusions: Both models consider the nonlinearity and random behavior present in this type of load, validating their inclusion in computer models of electric power systems.

  8. Magnesium isotope geochemistry in arc volcanism

    Science.gov (United States)

    Teng, Fang-Zhen; Hu, Yan; Chauvel, Catherine

    2016-06-01

    Incorporation of subducted slab in arc volcanism plays an important role in producing the geochemical and isotopic variations in arc lavas. The mechanism and process by which the slab materials are incorporated, however, are still uncertain. Here, we report, to our knowledge, the first set of Mg isotopic data for a suite of arc lava samples from Martinique Island in the Lesser Antilles arc, which displays one of the most extreme geochemical and isotopic ranges, although the origin of this variability is still highly debated. We find the δ26Mg of the Martinique Island lavas varies from -0.25 to -0.10, in contrast to the narrow range that characterizes the mantle (-0.25 ± 0.04, 2 SD). These high δ26Mg values suggest the incorporation of isotopically heavy Mg from the subducted slab. The large contrast in MgO content between peridotite, basalt, and sediment makes direct mixing between sediment and peridotite, or assimilation by arc crust sediment, unlikely to be the main mechanism to modify Mg isotopes. Instead, the heavy Mg isotopic signature of the Martinique arc lavas requires that the overall composition of the mantle wedge is buffered and modified by the preferential addition of heavy Mg isotopes from fluids released from the altered subducted slab during fluid-mantle interaction. This, in turn, suggests transfer of a large amount of fluid-mobile elements from the subducting slab to the mantle wedge and makes Mg isotopes an excellent tracer of deep fluid migration.

  9. Magnesium isotope geochemistry in arc volcanism.

    Science.gov (United States)

    Teng, Fang-Zhen; Hu, Yan; Chauvel, Catherine

    2016-06-28

    Incorporation of subducted slab in arc volcanism plays an important role in producing the geochemical and isotopic variations in arc lavas. The mechanism and process by which the slab materials are incorporated, however, are still uncertain. Here, we report, to our knowledge, the first set of Mg isotopic data for a suite of arc lava samples from Martinique Island in the Lesser Antilles arc, which displays one of the most extreme geochemical and isotopic ranges, although the origin of this variability is still highly debated. We find the δ(26)Mg of the Martinique Island lavas varies from -0.25 to -0.10, in contrast to the narrow range that characterizes the mantle (-0.25 ± 0.04, 2 SD). These high δ(26)Mg values suggest the incorporation of isotopically heavy Mg from the subducted slab. The large contrast in MgO content between peridotite, basalt, and sediment makes direct mixing between sediment and peridotite, or assimilation by arc crust sediment, unlikely to be the main mechanism to modify Mg isotopes. Instead, the heavy Mg isotopic signature of the Martinique arc lavas requires that the overall composition of the mantle wedge is buffered and modified by the preferential addition of heavy Mg isotopes from fluids released from the altered subducted slab during fluid-mantle interaction. This, in turn, suggests transfer of a large amount of fluid-mobile elements from the subducting slab to the mantle wedge and makes Mg isotopes an excellent tracer of deep fluid migration.

  10. Recent ARC developments: Through modularity to interoperability

    Energy Technology Data Exchange (ETDEWEB)

    Smirnova, O; Cameron, D; Ellert, M; Groenager, M; Johansson, D; Kleist, J [NDGF, Kastruplundsgade 22, DK-2770 Kastrup (Denmark); Dobe, P; Joenemo, J; Konya, B [Lund University, Experimental High Energy Physics, Institute of Physics, Box 118, SE-22100 Lund (Sweden); Fraagaat, T; Konstantinov, A; Nilsen, J K; Saada, F Ould; Qiang, W; Read, A [University of Oslo, Department of Physics, P. O. Box 1048, Blindern, N-0316 Oslo (Norway); Kocan, M [Pavol Jozef Safarik University, Faculty of Science, Jesenna 5, SK-04000 Kosice (Slovakia); Marton, I; Nagy, Zs [NIIF/HUNGARNET, Victor Hugo 18-22, H-1132 Budapest (Hungary); Moeller, S [University of Luebeck, Inst. Of Neuro- and Bioinformatics, Ratzeburger Allee 160, D-23538 Luebeck (Germany); Mohn, B, E-mail: oxana.smirnova@hep.lu.s [Uppsala University, Department of Physics and Astronomy, Div. of Nuclear and Particle Physics, Box 535, SE-75121 Uppsala (Sweden)

    2010-04-01

    The Advanced Resource Connector (ARC) middleware introduced by NorduGrid is one of the basic Grid solutions used by scientists worldwide. While being well-proven in daily use by a wide variety of scientific applications at large-scale infrastructures like the Nordic DataGrid Facility (NDGF) and smaller scale projects, production ARC of today is still largely based on conventional Grid technologies and custom interfaces introduced a decade ago. In order to guarantee sustainability, true cross-system portability and standards-compliance based interoperability, the ARC community undertakes a massive effort of implementing modular Web Service (WS) approach into the middleware. With support from the EU KnowARC project, new components were introduced and the existing key ARC services got extended with WS technology based standard-compliant interfaces following a service-oriented architecture. Such components include the hosting environment framework, the resource-coupled execution service, the re-engineered client library, the self-healing storage solution and the peer-to-peer information system, to name a few. Gradual introduction of these new services and client tools into the production middleware releases is carried out together with NDGF and thus ensures a smooth transition to the next generation Grid middleware. Standard interfaces and modularity of the new component design are essential for ARC contributions to the planned Universal Middleware Distribution of the European Grid Initiative.

  11. New method for capturing arc of moving on switching apparatus

    Institute of Scientific and Technical Information of China (English)

    LIU Jiao-min; WANG Jing-hong

    2007-01-01

    The switching arc that occurs in contact gap when contact of low voltage apparatus closes or breaks in electric circuit is harmful to the contacts, insulation, and reliability of electrical gear because of its very high temperature. As arcing time is very short in switching gear, it is very difficult to observe arc phenomena directly for researchers. Therefore, visualization of switching arc is important for understanding arc phenomena, to analyze the arc features, and to improve the design and reliability of switching gear. Based on analyzing the visualization methods proposed by researchers, a new switching arc capturing approach is introduced in this paper. Arc image acquisition, and image processing techniques were studied. A switching arc image acquisition and visual simulation software based on high speed CCD camera hard ware system was designed and implemented to yield enhanced arc image with good visual effect.

  12. Formation of metal oxides by cathodic arc deposition

    Energy Technology Data Exchange (ETDEWEB)

    Anders, S.; Anders, A.; Rubin, M.; Wang, Z.; Raoux, S.; Kong, F.; Brown, I.G.

    1995-03-01

    Metal oxide thin films are of interest for a number of applications. Cathodic arc deposition, an established, industrially applied technique for formation of nitrides (e.g. TiN), can also be used for metal oxide thin film formation. A cathodic arc plasma source with desired cathode material is operated in an oxygen atmosphere, and metal oxides of various stoichiometric composition can be formed on different substrates. We report here on a series of experiments on metal oxide formation by cathodic arc deposition for different applications. Black copper oxide has been deposited on ALS components to increase the radiative heat transfer between the parts. Various metal oxides such as tungsten oxide, niobium oxide, nickel oxide and vanadium oxide have been deposited on ITO glass to form electrochromic films for window applications. Tantalum oxide films are of interest for replacing polymer electrolytes. Optical waveguide structures can be formed by refractive index variation using oxide multilayers. We have synthesized multilayers of Al{sub 2}O{sub 3}/Y{sub 2}O{sub 3}/AI{sub 2}O{sub 3}/Si as possible basic structures for passive optoelectronic integrated circuits, and Al{sub 2-x}Er{sub x}O{sub 3} thin films with a variable Er concentration which is a potential component layer for the production of active optoelectronic integrated devices such as amplifiers or lasers at a wavelength of 1.53 {mu}m. Aluminum and chromium oxide films have been deposited on a number of substrates to impart improved corrosion resistance at high temperature. Titanium sub-oxides which are electrically conductive and corrosion resistant and stable in a number of aggressive environments have been deposited on various substrates. These sub-oxides are of great interest for use in electrochemical cells.

  13. Making and breaking an Island arc: a new perspective from the Oligocene Kyushu-Palau arc

    Science.gov (United States)

    Ishizuka, O.; Taylor, R. N.; Yuasa, M.; Ohara, Y.

    2010-12-01

    The Kyushu-Palau Ridge (KPR) is a 2000km long remnant island arc that is separated from the active Izu-Bonin-Mariana (IBM) arc system by a series of spreading and rift basins. In this study we present 40Ar/39Ar ages and geochemical data for new samples taken from the entire length of the Kyushu-Palau arc. As such, this data provides the first comprehensive evaluation of temporal and spatial changes that are present in an Eocene-Oligocene island arc. Kyushu-Palau arc geochemistry is evaluated alongside new data from the conjugate arc which is stranded within the IBM fore-arc. Boninitic magmatism gave way to transitional arc suites including high-Mg andesites at c. 45 Ma (Ishizuka et al., 2006). After the transitional 45-41 Ma period, a mature arc system developed through the Eocene-Oligocene time: This volcanism is now preserved as the KPR. Dating results from 33 sites indicate that the KPR was active between 25 and 43 Ma, but the majority of the exposed volcanism occurred in the final phase of this arc, between 25 and 27 Ma. Unlike the IBM, the KPR has only limited systematic along-arc trends and does not include any of the strongly HIMU lavas found to the south of Izu-Bonin. Two components found along the KPR are found to have geochemistry that suggests an origin in the supra-subduction mantle rather than from the descending ocean crust. Firstly, in the south of the arc, EM-2-like lavas are present where the West Philippine Basin was in the final stages of spreading. Secondly, EM-1-like lavas are present in a restricted section of the arc, suggesting a localised heterogeneity. Subduction flux beneath the KPR generally imparted a Pb isotope vector towards low Δ8/4 (19). This is a similar trend to the Eocene/Oligocene lavas found on the eastern side of the basins which split the arc at 25Ma. Another geochemical heterogeneity is found at the KPR-Daito Ridge intersection where arc magmatism occurred on pre-existing Daito Ridge crust: a Cretaceous remnant arc

  14. eDelivery

    Data.gov (United States)

    US Agency for International Development — eDelivery provides the electronic packaging and delivery of closed and complete OPM investigation files to government agencies, including USAID, in a secure manner....

  15. Direct probing of anode arc root dynamics and voltage instability in a dc non-transferred arc plasma jet

    Science.gov (United States)

    Ghorui, S.; Tiwari, N.; Meher, K. C.; Jan, A.; Bhat, A.; Sahasrabudhe, S. N.

    2015-12-01

    The transient dynamics of the anode arc root in a dc non-transferred arc plasma torch is captured through fast photography and directly correlated with the associated voltage instability for the first time. The coexistence of multiple arc roots, the transition to a single arc root, root formation and extinction are investigated for the steady, takeover and re-strike modes of the arc. Contrary to the usual concept, the emerging plasma jet of a dc non-transferred arc plasma torch is found to carry current. An unusually long self-propelled arc plasma jet, a consequence of the phenomenon, is demonstrated.

  16. Initiation of extended arc discharge in ICF reactor dense atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Kislev, H.

    1986-01-01

    Reduced density plasma channels are essential for LIB transport from external diodes to an ICF pellet centered in the 2-4 MPa superheated steamfilled cavity of the Heavy Water ICF Reactor. Forming such channels by ohmic heating requires the initiation of straight arc discharges along each beamline. The goal of this thesis is to evaluate the threshold beamline preionization and applied electric field for arc initiation. The capability of several preionizers to produce a straight preionized trail is evaluated through a ten-group Boltzmann equation solver. Electron densities around 10/sup 17/ m/sup -3/ could be maintained in the trail by monojoule output external preionizers. Trail preionization through the co-application of UV and CO/sub 2/ lasers appears to be the most promising technique. UV laser preionization of NO(a/sup 4/..pi..) formed in the fireball shows also good prospective. The large divergence of soft x-ray sources reduces their attractivity. The E/N dependent electron transport properties are used to construct the first streamer model capable of evaluating the steady state streamer wave shape. The streamers-induced highly ionized filament transition into a multi-kA carrying plasma channel is simulated by a modified radiation-MHD one-dimensional code.

  17. Evaluation of volumetric modulated arc therapy (VMAT with Oncentra MasterPlan® for the treatment of head and neck cancer

    Directory of Open Access Journals (Sweden)

    Koelbl Oliver

    2010-11-01

    Full Text Available Abstract Background Several comparison studies have shown the capability of VMAT to achieve similar or better plan quality as IMRT, while reducing the treatment time. The experience of VMAT in a multi vendor environment is limited. We compared the plan quality and performance of VMAT to IMRT and we investigate the effects of varying various user-selectable parameters. Methods IMRT, single arc VMAT and dual arc VMAT were compared for four different head-and-neck tumors. For VMAT, the effect of varying gantry angle spacing and treatment time on the plan quality was investigated. A comparison of monitor units and treatment time was performed. Results IMRT and dual arc VMAT achieved a similar plan quality, while single arc could not provide an acceptable plan quality. Increasing the number of control points does not improve the plan quality. Dual arc VMAT delivery time is about 30% of IMRT delivery time. Conclusions Dual arc VMAT is a fast and accurate technique for the treatment of head and neck cancer. It applies similar number of MUs as IMRT, but the treatment time is strongly reduced, maintaining similar or better dose conformity to the PTV and OAR sparing.

  18. 4' and 24' Shock Tubes - Electric Arc Shock Tube Facililty N-229 (East) The facility is used to

    Science.gov (United States)

    1978-01-01

    4' and 24' Shock Tubes - Electric Arc Shock Tube Facililty N-229 (East) The facility is used to investigate the effects of radiation and ionization during outer planetary entries as well as for air-blast simualtion which requires the strongest possible shock generation in air at loadings of 1 atm or greater.

  19. Volumetric modulated arc therapy and breath-hold in image-guided locoregional left-sided breast irradiation

    NARCIS (Netherlands)

    Osman, S.O.; Hol, S.; Poortmans, P.M.P.; Essers, M.

    2014-01-01

    PURPOSE: To investigate the effects of using volumetric modulated arc therapy (VMAT) and/or voluntary moderate deep inspiration breath-hold (vmDIBH) in the radiation therapy (RT) of left-sided breast cancer including the regional lymph nodes. MATERIALS AND METHODS: For 13 patients, four treatment co

  20. SU-E-T-508: End to End Testing of a Prototype Eclipse Module for Planning Modulated Arc Therapy On the Siemens Platform

    Energy Technology Data Exchange (ETDEWEB)

    Huang, L [Huntsman Cancer Hospital, Salt Lake City, UT (United States); Sarkar, V [University of Utah Hospitals, Salt Lake City, UT (United States); Spiessens, S [Varian Medical Systems France, Buc Cedex (France); Rassiah-Szegedi, P; Huang, Y; Salter, B [University Utah, Salt Lake City, UT (United States); Zhao, H [University of Utah, Salt Lake City, UT (United States); Szegedi, M [Huntsman Cancer Hospital, The University of Utah, Salt Lake City, UT (United States)

    2014-06-01

    Purpose: The latest clinical implementation of the Siemens Artiste linac allows for delivery of modulated arcs (mARC) using full-field flattening filter free (FFF) photon beams. The maximum doserate of 2000 MU/min is well suited for high dose treatments such as SBRT. We tested and report on the performance of a prototype Eclipse TPS module supporting mARC capability on the Artiste platform. Method: our spine SBRT patients originally treated with 12/13 field static-gantry IMRT (SGIMRT) were chosen for this study. These plans were designed to satisfy RTOG0631 guidelines with a prescription of 16Gy in a single fraction. The cases were re-planned as mARC plans in the prototype Eclipse module using the 7MV FFF beam and required to satisfy RTOG0631 requirements. All plans were transferred from Eclipse, delivered on a Siemens Artiste linac and dose-validated using the Delta4 system. Results: All treatment plans were straightforwardly developed, in timely fashion, without challenge or inefficiency using the prototype module. Due to the limited number of segments in a single arc, mARC plans required 2-3 full arcs to yield plan quality comparable to SGIMRT plans containing over 250 total segments. The average (3%/3mm) gamma pass-rate for all arcs was 98.5±1.1%, thus demonstrating both excellent dose prediction by the AAA dose algorithm and excellent delivery fidelity. Mean delivery times for the mARC plans(10.5±1.7min) were 50-70% lower than the SGIMRT plans(26±2min), with both delivered at 2000 MU/min. Conclusion: A prototype Eclipse module capable of planning for Burst Mode modulated arc delivery on the Artiste platform has been tested and found to perform efficiently and accurately for treatment plan development and delivered-dose prediction. Further investigation of more treatment sites is being carried out and data will be presented.

  1. Effects of process parameters on arc shape and penetration in twin-wire indirect arc welding

    Institute of Scientific and Technical Information of China (English)

    Shun-shan ZHANG; Mei-qing CAO; Dong-ting WU; Zeng-da ZOU

    2009-01-01

    In this study, the effects of variable parameters on arc shape and depth of penetration in twin-wire indirect arc gas shielded welding were investigated. The variation of arc shape caused by changes of the parameters was recorded by a high-speed camera,and the depths of penetration of specimen were measured after bead welding by an optical microscope. Experiments indicated that proper parameters give birth to a concentrated and compressed welcimg arc, which Would increase the depth of penetration as the incensement of the arc foice Several pnncipal parameters including toe distance ot twin wires intersecting point to base metal,the included angle,and the content of shielding gas were determined. The arc turned more concentrated and the depth of penetration increased obviously as the welding current increased,the arc turned brighter while unobvlous change of penetration occurred as the arc voltage increased,and the deepest penetration was obtained when the welding speed was 10.5 mm/s..

  2. The variable polarity plasma arc welding process: Characteristics and performance

    Science.gov (United States)

    Hung, R. J.; Zhu, G. J.

    1991-01-01

    Significant advantages of the Variable Polarity Plasma Arc (VPPA) Welding Process include faster welding, fewer repairs, less joint preparation, reduced weldment distortion, and absence of porosity. The power distribution was analyzed for an argon plasma gas flow constituting the fluid in the VPPA Welding Process. The major heat loss at the torch nozzle is convective heat transfer; in the space between the outlet of the nozzle and the workpiece; radiative heat transfer; and in the keyhole in the workpiece, convective heat transfer. The power absorbed at the workpiece produces the molten puddle that solidifies into the weld bead. Crown and root widths, and crown and root heights of the weld bead are predicted. The basis is provided for an algorithm for automatic control of VPPA welding machine parameters to obtain desired weld bead dimensions.

  3. Radiation Protection

    Science.gov (United States)

    ... EPA United States Environmental Protection Agency Search Search Radiation Protection Share Facebook Twitter Google+ Pinterest Contact Us Radiation Protection Document Library View and download EPA radiation ...

  4. GUI for studying the parameters influence of the electric arc model for a three-phase electric arc furnace

    Science.gov (United States)

    Ghiormez, L.; Prostean, O.; Panoiu, M.; Panoiu, C.

    2017-01-01

    This paper presents an analysis regarding the modeling of the behavior for a three-phase electric arc furnace installation. Therefore, a block diagram is implemented in Simulink that represents the modeling of the entire electric arc furnace installation. This block diagram contains also the modeling of the electric arc which is the element that makes the electric arc furnace behaving as a nonlinear load. The values for the model parameters of the electric arc furnace installation are like the ones from the real installation taken into consideration. Other model parameters are the electric arc model ones. In order to study the influence of the parameters of the electric arc models, it is developed a Matlab program that contains the graphical user interfaces. These interfaces make connection with the models of the electric arc implemented in Simulink. The interfaces allow the user to modify parameters for each of the electric arc model. Current and voltage of the electric arc are the variables taken into account to study the influence of the parameters on the electric arc models. Waveforms for voltage and current of the electric arc are illustrated when a parameter of the model is modified in order to analyze the importance of this parameter on the electric arc model. Also, for each of the models is presented the voltage-current characteristic of the electric arc because this characteristic gives information about the behavior of the electric arc furnace installation.

  5. On Possible Arc Inception on Low Voltage Solar Array

    Science.gov (United States)

    Vayner, Boris

    2015-01-01

    Recent analysis of spacecraft failures during the period of 1990-2013 demonstrated clearly that electrostatic discharges caused more than 8 percent of all registered failures and anomalies, and comprised the most costly losses (25 percent) for operating companies and agencies. The electrostatic discharges on spacecraft surfaces are the results of differential charging above some critical (threshold) voltages. The mechanisms of differential charging are well known, and various methods have been developed to prevent a generation of significant electric fields in areas of triple junctions. For example, low bus voltages in Low Earth Orbit plasma environment and slightly conducting layer over cover-glass (ITO) in Geosynchronous Orbit surroundings are believed to be quite reliable measures to prevent discharges on respective surfaces. In most cases, the vulnerable elements of spacecraft (solar arrays, diode boards, etc.) go through comprehensive ground tests in vacuum chambers. However, tests articles contain the miniscule fragments of spacecraft components such as 10-30 solar cells of many thousands deployed on spacecraft in orbit. This is one reason why manufacturing defects may not be revealed in ground tests but expose themselves in arcing on array surface in space. The other reason for ineffectiveness of discharge preventive measures is aging of all materials in harsh orbital environments. The expected life time of modern spacecraft varies within the range of five-fifteen years, and thermal cycling, radiation damages, and mechanical stresses can result in surface erosion on conductive layers and microscopic cracks in cover-glass sheets and adhesive films. These possible damages may cause significant increases in local electric field strengths and subsequent discharges. The primary discharges may or may not be detrimental to spacecraft operation, but they can produce the necessary conditions for sustained arcs initiation. Multiple measures were developed to prevent

  6. Method to reduce arc blow during DC arc welding of pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Espina-Hernandez, J. H.; Rueda-Morales, G.L.; Caleyo, F.; Hallen, J. M. [Instituto Politecnico Nacional, Mexico, (Mexico); Lopez-Montenegro, A.; Perz-Baruch, E. [Pemex Exploracion y Produccion, Tabasco, (Mexico)

    2010-07-01

    Steel pipelines are huge ferromagnetic structures and can be easily subjected to arc blow during the DC arc welding process. The development of methods to avoid arc blow during pipeline DC arc welding is a major objective in the pipeline industry. This study developed a simple procedure to compensate the residual magnetic field in the groove during DC arc welding. A Gaussmeter was used to perform magnetic flux density measurements in pipelines in southern Mexico. These data were used to perform magnetic finite element simulations using FEMM. Different variables were studied such as the residual magnetic field in the groove or the position of the coil with respect to the groove. An empirical predictive equation was developed from these trials to compensate for the residual magnetic field. A new method of compensating for the residual magnetic field in the groove by selecting the number of coil turns and the position of the coil with respect to the groove was established.

  7. Overview of ArcGIS Engine Controls%ArcGIS Engine控件综述

    Institute of Scientific and Technical Information of China (English)

    刘磊

    2010-01-01

    ArcGIS Engine是ESRI公司发布的嵌入式地理信息系统软件开发包.基于ArcGIS Engine开发的应用程序一般有3类:独立非可视化应用程序、独立可视化应用程序和嵌入式应用程序,由于ArcGIS Engine提供了一套可复用、跨平台、设计良好的ArcGIS控件,因此利用控件开发可视化的GIS应用程序是一种常用的开发方式.重点探讨了ArcGIS Engine自带控件的功能、使用方法以及与伙伴控件之间的联系机制.

  8. Research of Arc Chamber Optimization Techniques Based on Flow Field and Arc Joint Simulation

    Science.gov (United States)

    Zhong, Jianying; Guo, Yujing; Zhang, Hao

    2016-03-01

    The preliminary design of an arc chamber in the 550 kV SF6 circuit breaker was proposed in accordance with the technical requirements and design experience. The structural optimization was carried out according to the no-load flow field simulation results and verified by no-load pressure measurement. Based on load simulation results such as temperature field variation at the arc area and the tendency of post arc current under different recovery voltage, the second optimal design was completed and its correctness was certificated by a breaking test. Results demonstrate that the interrupting capacity of an arc chamber can be evaluated by the comparison of the gas medium recovery speed and post arc current growth rate.

  9. Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines

    Science.gov (United States)

    Cong, Haoxi; Li, Qingmin; Xing, Jinyuan; Li, Jinsong; Chen, Qiang

    2015-06-01

    The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low-voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines. supported by National Natural Science Foundation of China (Nos. 51277061 and 51420105011)

  10. Gas Arcs in Comet Hyakutake: Revisited

    Science.gov (United States)

    Combi, M. R.; Harris, W. M.; Kabin, K.

    2000-10-01

    The recent break-up of the nucleus of Comet LINEAR S4 demonstrates that fragmentation is an important cometary process and that it is not a rare phenomenon. Comet Hyakutake (1996 B2) underwent an outburst of gas production on March 21, 1996. Subsequent to the outburst, fragments, or condensations as they have been called, were observed moving tailward from the position of the nucleus. Arc-shaped structures were seen in images of gas species (OH, CN and C2) providing clear evidence of production of gas from cometary nucleus debris also tailward of the nucleus. We have already (Harris et al. 1997, Science 277, 676) described observations taken with the WIYN telescope consisting of a 6-hour time sequence of images on March 26, 1996 of CN and dust continuum and a single OH image showing that the arc, and by inference it's source, was generally moving tailward with the visible condensations. The entire OH arc was reproduced using a kinetic Direct Simulation Monte Carlo (DSMC) calculation for water and all its photodissociation products. DSMC is suited to this physical environment that is in transition from fluid conditions in the inner coma to free-expansion in the outer coma. Our model asuming a string of fragments within the apex of the arc (i.e., the intersection of the arc and the tailward sun-comet line) reproduced the arc. Here we present a more extensive parameter study of the arc using DSMC and a solution of the standard perfect-fluid Euler equations. We find that a secondary source just behind the apex of the arc can reproduce the OH arc, but the location of the source must be much closer to the apex than indicated by solutions of the Navier-Stokes equations (NSE) (Rodionov et al. 1998, Icarus 136, 232). We find that we must use unrealistically large collision cross sections to reproduce the NSE results, and that the NSE results are not substantially different from a simpler Euler equation approach. This work has been supported by NASA Planetary Atmospheres

  11. The geochemistry and petrogenesis of the Paleoproterozoic Green Mountain arc: A composite(?), bimodal, oceanic, fringing arc

    Science.gov (United States)

    Jones, D.S.; Barnes, C.G.; Premo, W.R.; Snoke, A.W.

    2011-01-01

    The inferred subduction affinity of the ~1780-Ma Green Mountain arc, a dominantly bimodal igneous terrane (together with immature marine and volcaniclastic sedimentary rocks) accreted to the southern margin of the Wyoming province, is integral to arc-accretion models of the Paleoproterozoic growth of southern Laurentia. Conversely, the dominantly bimodal nature of many putative arc-related igneous suites throughout southern Laurentia, including the Green Mountain arc, has also been used to support models of growth by extension of pre-existing crust. We report new geochemical and isotopic data from ~1780-Ma gabbroic and granodioritic to tonalitic rocks of the Big Creek Gneiss, interpreted as consanguineous with previously studied metavolcanic rocks of the Green Mountain Formation.The ~1780-Ma Big Creek Gneiss mafic rocks show clear geochemical signatures of a subduction origin and provide no supporting evidence for extensional tectonism. The ~1780-Ma Big Creek Gneiss felsic rocks are attributed to partial melting of mafic and/or mixed lower-crustal material. The bimodal nature of the suite results from the combination of arc basalts and felsic crustal melts. The lack of andesite is consistent with the observed tholeiitic differentiation trend of the mafic magmas. The lower e{open}Nd(1780Ma) values for the felsic rocks vs. the mafic rocks suggest that the unexposed lower crust of the arc may be older than the arc and that Trans-Hudson- or Penokean-aged rocks possibly form the substratum of the arc. Our results reinforce previous interpretations that arc-related magmatism played a key role in the Paleoproterozoic crustal growth of southern Laurentia, but also support the possibility of unexposed older crust as basement to the arcs. ?? 2011 Elsevier B.V.

  12. BASIC THEORY AND METHOD OF WELDING ARC SPECTRAL INFORMATION

    Institute of Scientific and Technical Information of China (English)

    Li Junyue; Li Zhiyong; Li Huan; Xue Haitao

    2004-01-01

    Arc spectral information is a rising information source which can solve many problems that can not be done with arc electric information and other arc information.It is of important significance to develop automatic control technique of welding process.The basic theory and methods on it play an important role in expounding and applying arc spectral information.Using concerned equation in plasma physics and spectrum theory,a system of equations including 12 equations which serve as basic theory of arc spectral information is set up.Through analyzing of the 12 equations,a basic view that arc spectral information is the reflection of arc state and state variation,and is the most abundant information resource reflecting welding arc process is drawn.Furthermore,based on the basic theory,the basic methods of test and control of arc spectral information and points out some applications of it are discussesed.

  13. Arc Conductance and Flow Velocity Affected by Transient Recovery Voltage

    Science.gov (United States)

    Fukuoka, Reo; Ishikawa, Yuya; Ono, Seisui; Sato, Ken; Yamamoto, Shinji; Iwao, Toru

    2016-09-01

    Recently, the stable supply of electric power is indispensable. The GCB (Gas Circuit Breaker) can prevent the spread of the fault current. However, it should have the reliability more. Therefore the GCB has been researched for performance improvement of the arc interruption of abnormal fault current without the fail. Therefore, it is important to prevent the breakdown such as the re-ignition and thermal re-ignition of arc after the arc interruption. It is necessary to reduce the arc conductance in order to prevent the re-ignition of arc. The arc conductance is derived from the temperature distribution and the volume of the arc. The temperature distribution of the arc is formed by convection. In this research, the arc conductance and flow velocity affected by transient recovery voltage are elucidated. The flow rate and temperature distribution of the arc is calculated with changing transient recovery voltage. In addition, the arc conductance is calculated in order to know the extinguish arc ability. As a result, when the transient recovery voltage increases, the probability of re-ignition increases. Therefore, the arc temperature and the arc conductance were increased.

  14. Colloidal drug delivery systems in vaccine delivery.

    Science.gov (United States)

    Beg, Sarwar; Samad, Abdus; Nazish, Iram; Sultana, Ruksar; Rahman, Mahfoozur; Ahmad, Md Zaki; Akbar, Md

    2013-01-01

    Vaccines play a vital role in the field of community medicine to combat against several diseases of human existence. Vaccines primarily trigger the acquired immune system to develop long-lasting immunity against pathogens. Conventional approaches for vaccine delivery lacks potential to target a particular antigen to develop acquired immunity by specific antibodies. Recent advancements in vaccine delivery showed that inclusion of adjuvants in vaccine formulations or delivery of them in a carrier helps in achieving desired targeting ability, reducing the immunogenicity and significant augmentation in the immune response. Colloidal carriers (liposomes, niosomes, microspheres, proteosomes, virosomes and virus like particles (VLPs), antigen cochleates, dendrimers and carbon nanotubes) have been widely explored for vaccine delivery. Further, surface engineering of these carriers with ligands, functional moieties and monoclonal antibodies tend to enhance the immune recognition potential of vaccines by differentiation of antigen specific memory T-cells. The current review, therefore, provides an updated account on the recent advancements in various colloidal delivery systems in vaccine delivery, outlining the mechanism of immune response initiated by them along with potential applications and marketed instances in an explicit manner.

  15. Radiation sickness

    Science.gov (United States)

    ... radiation. There are two basic types of radiation: ionizing and nonionizing. Nonionizing radiation comes in the form of light, radio waves, microwaves and radar. This kind of radiation usually ...

  16. Radiation enteritis

    Science.gov (United States)

    Radiation enteropathy; Radiation-induced small bowel injury; Post-radiation enteritis ... Radiation therapy uses high-powered x-rays, particles, or radioactive seeds to kill cancer cells. The therapy ...

  17. Radiation Therapy

    Science.gov (United States)

    ... the area is stitched shut. Another treatment, called proton-beam radiation therapy , focuses the radiation on the ... after radiation treatment ends. Sore mouth and tooth decay. If you received radiation therapy to the head ...

  18. Application of AAPM TG 119 to volumetric arc therapy (VMAT).

    Science.gov (United States)

    Mynampati, Dinesh Kumar; Yaparpalvi, Ravindra; Hong, Linda; Kuo, Hsiang-Chi; Mah, Dennis

    2012-09-06

    The purpose of this study was to create AAPM TG 119 benchmark plans for volumetric arc therapy (VMAT) and to compare VMAT plans with IMRT plan data. AAPM TG 119 proposes a set of test clinical cases for testing the accuracy of IMRT planning and delivery system. For these test cases, we generated two treatment plans, the first plan using 7-9 static dMLC IMRT fields and a second plan utilizing one- or two-arc VMAT technique. Dose optimization and calculations performed using 6 MV photons and Eclipse treatment planning system. Dose prescription and planning objectives were set according to the TG 119 goals. Plans were scored based on TG 119 planning objectives. Treatment plans were compared using conformity index (CI) for reference dose and homogeneity index (HI) (for D(5)-D(95)). For test cases prostate, head-and-neck, C-shape and multitarget prescription dose are 75.6 Gy, 50.4 Gy, 50 Gy and 50 Gy, respectively. VMAT dose distributions were comparable to dMLC IMRT plans. Our planning results matched TG 119 planning results. For treatment plans studied, conformity indices ranged from 1.05-1.23 (IMRT) and 1.04-1.23 (VMAT). Homogeneity indices ranged from 4.6%-11.0% (IMRT) and 4.6%-10.5% (VMAT). The ratio of total monitor units necessary for dMLC IMRT to that of VMAT was in the range of 1.1-2.0. AAPM TG 119 test cases are useful to generate VMAT benchmark plans. At preclinical implementation stage, plan comparison of VMAT and IMRT plans of AAPM TG 119 test case allowed us to understand basic capabilities of VMAT technique.

  19. Characterization of a high current pulsed arc using optical emission spectroscopy

    Science.gov (United States)

    Sousa Martins, R.; Zaepffel, C.; Chemartin, L.; Lalande, Ph; Soufiani, A.

    2016-10-01

    In this paper, we present the investigation realized on an experimental setup that simulates an arc column subjected to the transient phase of a lightning current waveform in laboratory conditions. Optical emission spectroscopy is employed to assess space- and time-resolved properties of this high current pulsed arc. Different current peak levels are utilised in this work, ranging from 10 kA to 100 kA, with a peak time around 15 µs. Ionic lines of nitrogen and oxygen are used to determine the radial profiles of temperature and electron density of the arc channel over time from 2 µs to 36 µs. A combination of 192 N II and O II lines is considered in the calculation of the bound-bound contribution of the absorption coefficient of the plasma channel. Calculations of the optical thickness showed that self-absorption of these ionic lines in the arc column is important. To obtain temperature and electron density profiles in the arc, we solved the radiative transfer equation across the channel under an axisymmetric assumption and considering the channel formed by uniform concentric layers. For the 100 kA current peak level, the temperature reaches more than 38 000 K and the electron density reaches 5  ×  1018 cm-3. The pressure inside the channel is calculated using the air plasma composition at local thermodynamic equilibrium, and reaches 45 bar. The results are discussed and utilised to estimate the electrical conductivity of the arc channel.

  20. Dosimetric study of volumetric-modulated arc radiotherapy and fixed field-intensity modulated radiation therapy for cervix ne-oplasms%宫颈癌容积调强与固定野动态调强放疗技术的剂量学比较

    Institute of Scientific and Technical Information of China (English)

    康梅; 权循凤; 李兵兵; 吴莉莉

    2016-01-01

    Objective To compare the dosimetric and organ at risk dose differences of volumetric modulated arc therapy( VMAT) , seven-fixed field intensity-modulated radiation therapy(7-IMRT) and nine-fixed field intensity-modulated radiation therapy(9-IMRT) for cer-vix cancer treated with the definitive whole pelvic radiotherapy. Methods CT images of twelve patients treated with three plans of VMAT,7-IMRT and 9-IMRT techniques were compared in terms of parameters of target,organ at risk( OAR) ,conformity index( HI) and conformity in-dex( CI) . The MUs were scored to measure the expected treatment efficiency. Results All the three plans could achieve the clinically ac-ceptable target coverage. The VMAT plans were the best,while 7-IMRT was the worst in HI and CI of targets. VMAT imposed least doses to the bladder at dose level of 30 Gy,the rectum at the dose level of 30 and 50 Gy. VMAT was the same least on femoral head the volume re-ceived 20 Gy(P<0. 05). Compared with 9-IMRT,7-IMRT showed compared volume of bladder at dose level of 30 Gy,and reduced the vol-ume of femoral head at 20 Gy. The MUs of VMAT plans(757. 69 ± 137. 04) were significantly less than those of 7-IMRT plans(802. 65 ± 183. 85) and 9-IMRT plans(1102. 31 ± 190. 07). Conclusion Three types of plans can achieve the clinical dosimetric demands and protect the OARs. VMAT has the best performance on CI and HI,and decrease the volume of the high-dose area in OARs. VMAT plans have fewer MUs and significantly improve the treatment efficiency regarding total MUs.%目的 比较旋转容积调强技术(VMAT)、固定7野(7-IMRT)及9野动态调强技术(9-IMRT)在宫颈癌根治性放疗中的剂量学参数.方法 选取12例接受根治性放疗的宫颈癌患者,对同一CT图像分别进行二弧VMAT、7野IMRT及9野IMRT计划设计,比较3种放疗计划的靶区剂量和危及器官的剂量学差异、靶区剂量适形度、均匀性以及加速器跳数.结果 VMAT、7-IMRT和9-IMRT计划的靶区剂量均

  1. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Energy Technology Data Exchange (ETDEWEB)

    Salter, Bill J; Sarkar, Vikren; Wang, Brian; Szegedi, Martin; Rassiah-Szegedi, Prema [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States); Shukla, Himanshu, E-mail: bill.salter@hci.utah.edu [Oncology Care Systems Group, Siemens Medical Solutions (USA), 4040 Nelson Avenue, Concord, CA (United States)

    2011-04-07

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min{sup -1}) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  2. Arc-welding robot. 2; Yosetsu robot

    Energy Technology Data Exchange (ETDEWEB)

    Nishikawa, S. [Yaskawa Electric Corp., Kitakyushu (Japan)

    1995-02-01

    This is an introductory lecture on the selection and handling of arc-welding robot and was explained easily in Q and A style. This is the second of its series and extraction examples of Q and A are Q: type of stations for setting works, A: fixed, slide, inversion, rotary types and their combination, Q: station type for constructing a highly universal system for a wide variety of works, A: a highly universal robot was realized owing to external shaft control function. Recently, one robot can control a maximum of 21 shafts to cope with a variety of works, Q: off-line teaching for arc-welding robot, A: yes. It is available but does not spread as much as for spot since arc welding requires a high tracing accuracy. 12 figs.

  3. Circular arc snakes and kinematic surface generation

    KAUST Repository

    Barton, Michael

    2013-05-01

    We discuss the theory, discretization, and numerics of curves which are evolving such that part of their shape, or at least their curvature as a function of arc length, remains unchanged. The discretization of a curve as a smooth sequence of circular arcs is well suited for such purposes, and allows us to reduce evolution of curves to the evolution of a control point collection in a certain finite-dimensional shape space. We approach this evolution by a 2-step process: linearized evolution via optimized velocity fields, followed by optimization in order to exactly fulfill all geometric side conditions. We give applications to freeform architecture, including "rationalization" of a surface by congruent arcs, form finding and, most interestingly, non-static architecture. © 2013 The Author(s) Computer Graphics Forum © 2013 The Eurographics Association and Blackwell Publishing Ltd.

  4. ArcForm - A multimodal notation

    DEFF Research Database (Denmark)

    Allsopp, Benjamin Brink

    ArcForm (AF) is a visual notation based on a new graph-like network structure. It supports a unique approach to labeling arcs and nodes to allow diverse and grammatically normal English (or other natural language) sentences to be embedded in the network (Allsopp, 2013). In doing this AF combines ...... as a notational foundation for e-learning platforms (Allsopp 2015). We will explore a prototype supporting basic interaction with the landscape and consider how it can benefit from virtual reality, online social curating and the block chain....... of individual nodes and arcs will allow us to create new perspectives on the underlying information. This presentation will use multiple visual examples to show how AF achieves its many affordances. We will discuss how it has been used in education research (Misfeldt 2016) and how it could be used...

  5. Radiation dosimetry.

    OpenAIRE

    Cameron, J

    1991-01-01

    This article summarizes the basic facts about the measurement of ionizing radiation, usually referred to as radiation dosimetry. The article defines the common radiation quantities and units; gives typical levels of natural radiation and medical exposures; and describes the most important biological effects of radiation and the methods used to measure radiation. Finally, a proposal is made for a new radiation risk unit to make radiation risks more understandable to nonspecialists.

  6. TU-CD-304-03: Dosimetric Verification and Preliminary Comparison of Dynamic Wave Arc for SBRT Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Burghelea, M [UZ BRUSSEL, Brussels (Belgium); BRAINLAB AG, Munich (Germany); Babes Bolyai University, Cluj-Napoca (Romania); Poels, K; Gevaert, T; Tournel, K; Dhont, J; De Ridder, M; Verellen, D [UZ BRUSSEL, Brussels (Belgium); Hung, C [BRAINLAB AG, Munich (Germany); Eriksson, K [RAYSEARCH LABORATORIES AB, Stockholm (Sweden); Simon, V [Babes Bolyai University, Cluj-Napoca (Romania)

    2015-06-15

    Purpose: To evaluate the potential dosimetric benefits and verify the delivery accuracy of Dynamic Wave Arc, a novel treatment delivery approach for the Vero SBRT system. Methods: Dynamic Wave Arc (DWA) combines simultaneous movement of gantry/ring with inverse planning optimization, resulting in an uninterrupted non-coplanar arc delivery technique. Thirteen SBRT complex cases previously treated with 8–10 conformal static beams (CRT) were evaluated in this study. Eight primary centrally-located NSCLC (prescription dose 4×12Gy or 8×7.5Gy) and five oligometastatic cases (2×2 lesions, 10×5Gy) were selected. DWA and coplanar VMAT plans, partially with dual arcs, were generated for each patient using identical objective functions for target volumes and OARs on the same TPS (RayStation, RaySearch Laboratories). Dosimetric differences and delivery time among these three planning schemes were evaluated. The DWA delivery accuracy was assessed using the Delta4 diode array phantom (ScandiDos AB). The gamma analysis was performed with the 3%/3mm dose and distance-to-agreement criteria. Results: The target conformity for CRT, VMAT and DWA were 0.95±0.07, 0.96±0.04 and 0.97±0.04, while the low dose spillage gradient were 5.52±1.36, 5.44±1.11, and 5.09±0.98 respectively. Overall, the bronchus, esophagus and spinal cord maximum doses were similar between VMAT and DWA, but highly reduced compared with CRT. For the lung cases, the mean dose and V20Gy were lower for the arc techniques compares with CRT, while for the liver cases, the mean dose and the V30Gy presented slightly higher values. The average delivery time of VMAT and DWA were 2.46±1.10 min and 4.25±1.67 min, VMAT presenting shorter treatment time in all cases. The DWA dosimetric verification presented an average gamma index passing rate of 95.73±1.54% (range 94.2%–99.8%). Conclusion: Our preliminary data indicated that the DWA is deliverable with clinically acceptable accuracy and has the potential to

  7. Magnesium isotope geochemistry in arc volcanism

    Science.gov (United States)

    Teng, Fang-Zhen; Hu, Yan

    2016-01-01

    Incorporation of subducted slab in arc volcanism plays an important role in producing the geochemical and isotopic variations in arc lavas. The mechanism and process by which the slab materials are incorporated, however, are still uncertain. Here, we report, to our knowledge, the first set of Mg isotopic data for a suite of arc lava samples from Martinique Island in the Lesser Antilles arc, which displays one of the most extreme geochemical and isotopic ranges, although the origin of this variability is still highly debated. We find the δ26Mg of the Martinique Island lavas varies from −0.25 to −0.10, in contrast to the narrow range that characterizes the mantle (−0.25 ± 0.04, 2 SD). These high δ26Mg values suggest the incorporation of isotopically heavy Mg from the subducted slab. The large contrast in MgO content between peridotite, basalt, and sediment makes direct mixing between sediment and peridotite, or assimilation by arc crust sediment, unlikely to be the main mechanism to modify Mg isotopes. Instead, the heavy Mg isotopic signature of the Martinique arc lavas requires that the overall composition of the mantle wedge is buffered and modified by the preferential addition of heavy Mg isotopes from fluids released from the altered subducted slab during fluid−mantle interaction. This, in turn, suggests transfer of a large amount of fluid-mobile elements from the subducting slab to the mantle wedge and makes Mg isotopes an excellent tracer of deep fluid migration. PMID:27303032

  8. On the Trail of Joan of Arc

    Directory of Open Access Journals (Sweden)

    Linda Joyce Forristal

    2013-12-01

    Full Text Available The year 2012 marked the 600th anniversary of the birthday of Joan of Arc (Fr., Jeanne d’Arc (1412–1431. Tributes to this national heroine can be found all over France. There are literally countless statues, streets and restaurants named after her and many sites dedicated to her life. However, despite widespread social and mechanical reproduction and cultural naming in relation to the Maid of Orléans, there is no official network or integrated signage in France to promote cultural heritage tourism to the numerous Joan of Arc sites and festivals, even though her life and death, by any measure, were seminal events in the country’s history. Unfortunately, the pilgrim who wants to follow or intersect with Joan of Arc’s trail through France, for cultural, historical or religious reasons, must do so without much help. Using Actor Network Theory and Site Sacralization Theory as framing devices, this paper explores human actors and tangible and intangible non-human factors that may have contributed to the lack of a unified tourism product despite the existence of an adequate Joan of Arc tourismscape. Insights gleaned from this research include Joan’s conflicted status as both/either saint and/or patriot, the existence of no cooperation or linkage between Joan of Arc sites, and cautious French tourism development policies. Several possible scenarios are suggested as suitable means to help implement or foster the creation of an on-the-ground or virtual Joan of Arc trail or tour.

  9. Plasma distribution of cathodic ARC deposition system

    Energy Technology Data Exchange (ETDEWEB)

    Anders, S.; Raoux, S.; Krishnan, K.; MacGill, R.A.; Brown, I.G. [Lawrence Berkeley National Lab., CA (United States)

    1996-08-01

    The plasma distribution using a cathodic arc plasma source with and without magnetic macroparticle filter has been determined by depositing on a transparent plastic substrate and measuring the film absorption. It was found that the width of the distribution depends on the arc current, and it also depends on the cathode material which leads to a spatial separation of the elements when an alloy cathode is used. By applying a magnetic multicusp field near the exit of the magnetic filter, it was possible to modify the plasma distribution and obtain a flat plasma profile with a constant and homogeneous elemental distribution.

  10. Ion source based on the cathodic arc

    Science.gov (United States)

    Sanders, David M.; Falabella, Steven

    1994-01-01

    A cylindrically symmetric arc source to produce a ring of ions which leave the surface of the arc target radially and are reflected by electrostatic fields present in the source to a point of use, such as a part to be coated. An array of electrically isolated rings positioned in the source serves the dual purpose of minimizing bouncing of macroparticles and providing electrical insulation to maximize the electric field gradients within the source. The source also includes a series of baffles which function as a filtering or trapping mechanism for any macroparticles.

  11. Architectural Surfaces and Structures from Circular Arcs

    KAUST Repository

    Shi, Ling

    2013-12-01

    In recent decades, the popularity of freeform shapes in contemporary architecture poses new challenges to digital design. One of them is the process of rationalization, i.e. to make freeform skins or structures affordable to manufacture, which draws the most attention from geometry researchers. In this thesis, we aim to realize this process with simple geometric primitives, circular arcs. We investigate architectural surfaces and structures consisting of circular arcs. Our focus is lying on how to employ them nicely and repetitively in architectural design, in order to decrease the cost in manufacturing. Firstly, we study Darboux cyclides, which are algebraic surfaces of order ≤ 4. We provide a computational tool to identify all families of circles on a given cyclide based on the spherical model of M ̈obius geometry. Practical ways to design cyclide patches that pass through certain inputs are presented. In particular, certain triples of circle families on Darboux cyclides may be suitably arranged as 3-webs. We provide a complete classification of all possible 3-webs of circles on Darboux cyclides. We then investigate the circular arc snakes, which are smooth sequences of circu- lar arcs. We evolve the snakes such that their curvature, as a function of arc length, remains unchanged. The evolution of snakes is utilized to approximate given surfaces by circular arcs or to generated freeform shapes, and it is realized by a 2-step pro- cess. More interestingly, certain 6-arc snake with boundary constraints can produce a smooth self motion, which can be employed to build flexible structures. Another challenging topic is approximating smooth freeform skins with simple panels. We contribute to this problem area by approximating a negatively-curved 5 surface with a smooth union of rational bilinear patches. We provide a proof for vertex consistency of hyperbolic nets using the CAGD approach of the rational B ́ezier form. Moreover, we use Darboux transformations for the

  12. Arcing Model of a Disconnector and its Effect on VFTO

    Science.gov (United States)

    Lin, Xin; Wang, Na; Xu, Jianyuan

    2013-07-01

    In the computational process of very fast transient over-voltage (VFTO), it is essential to find an accurate model for a gas insulated substation. The arcing model of the disconnector is particularly important. The general arcing model is not able to give a good description of the arc development process. In this paper, based on the physical process of arcing and existing arc models (the exponential time-varying resistance model and the segmental arcing models), a dynamic arcing model is proposed, which is divided into two stages before and after the zero crossing. The dynamic arcing model combines hyperbola time-varying resistance and the Mayr model to describe the dynamic process of arcing. The present paper creates an arc model blockset upon the Matlab/Simulink software platform. Moreover for a specific 1100 kV station, VFTO is simulated in detail based on different arcing models. It is demonstrated that the dynamic arcing model can describe the physical arc process precisely and is useful for improving the accuracy of VFTO simulations.

  13. A Monte Carlo tool for evaluating VMAT and DIMRT treatment deliveries including planar detectors

    Science.gov (United States)

    Asuni, G.; van Beek, T. A.; Venkataraman, S.; Popescu, I. A.; McCurdy, B. M. C.

    2013-06-01

    The aim of this work is to describe and validate a new general research tool that performs Monte Carlo (MC) simulations for volumetric modulated arc therapy (VMAT) and dynamic intensity modulated radiation therapy (DIMRT), simultaneously tracking dose deposition in both the patient CT geometry and an arbitrary planar detector system. The tool is generalized to handle either entrance or exit detectors and provides the simulated dose for the individual control-points of the time-dependent VMAT and DIMRT deliveries. The MC simulation tool was developed with the EGSnrc radiation transport. For the individual control point simulation, we rotate the patient/phantom volume only (i.e. independent of the gantry and planar detector geometries) using the gantry angle in the treatment planning system (TPS) DICOM RP file such that each control point has its own unique phantom file. After MC simulation, we obtained the total dose to the phantom by summing dose contributions for all control points. Scored dose to the sensitive layer of the planar detector is available for each control point. To validate the tool, three clinical treatment plans were used including VMAT plans for a prostate case and a head-and-neck case, and a DIMRT plan for a head-and-neck case. An electronic portal imaging device operated in ‘movie’ mode was used with the VMAT plans delivered to cylindrical and anthropomorphic phantoms to validate the code using an exit detector. The DIMRT plan was delivered to a novel transmission detector, to validate the code using an entrance detector. The total MC 3D absolute doses in patient/phantom were compared with the TPS doses, while 2D MC doses were compared with planar detector doses for all individual control points, using the gamma evaluation test with 3%/3 mm criteria. The MC 3D absolute doses demonstrated excellent agreement with the TPS doses for all the tested plans, with about 95% of voxels having γ 90% of percentage pixels with γ <1. We found that over

  14. Project delivery system (PDS)

    CERN Document Server

    2001-01-01

    As business environments become increasingly competitive, companies seek more comprehensive solutions to the delivery of their projects. "Project Delivery System: Fourth Edition" describes the process-driven project delivery systems which incorporates the best practices from Total Quality and is aligned with the Project Management Institute and ISO Quality Standards is the means by which projects are consistently and efficiently planned, executed and completed to the satisfaction of clients and customers.

  15. Simulation of the Process of Arc Energy-Effect in High Voltage Auto-Expansion SF6 Circuit Breaker

    Institute of Scientific and Technical Information of China (English)

    Rong Mingzhe; Yang Qian; Fan Chunduo

    2005-01-01

    A new magnetic hydro-dynamics (MHD) model of arc in H.V. auto-expansion SF6circuit breaker that takes into consideration nozzle ablation due to both radiation and thermal conduction is presented in this paper. The effect of PTFE (polytetrafluorethylene) vapor is considered in the mass, momentum and energy conservation equations of the constructed model. Then,the gas flow fields with and without conduction considered are simulated. By comparing the aforementioned two results, it is indicated that the arc's maximal temperature with conduction considered is 90 percent of that without considering conduction.

  16. Early clinical experience with volumetric modulated arc therapy in head and neck cancer patients

    Directory of Open Access Journals (Sweden)

    Cozzi Luca

    2010-10-01

    Full Text Available Abstract Background To report about early clinical experience in radiation treatment of head and neck cancer of different sites and histology by volumetric modulated arcs with the RapidArc technology. Methods During 2009, 45 patients were treated at Istituto Clinico Humanitas with RapidArc (28 males and 17 females, median age 65 years. Of these, 78% received concomitant chemotherapy. Thirty-six patients were treated as exclusive curative intent (group A, three as postoperative curative intent (group B and six with sinonasal tumours (group C. Dose prescription was at Planning Target Volumes (PTV with simultaneous integrated boost: 54.45Gy and 69.96Gy in 33 fractions (group A; 54.45Gy and 66Gy in 33 fractions (group B and 55Gy in 25 fractions (group C. Results Concerning planning optimization strategies and constraints, as per PTV coverage, for all groups, D98% > 95% and V95% > 99%. As regards organs at risk, all planning objectives were respected, and this was correlated with observed acute toxicity rates. Only 28% of patients experienced G3 mucositis, 14% G3 dermitis 44% had G2 dysphagia. Nobody required feeding tubes to be placed during treatment. Acute toxicity is also related to chemotherapy. Two patients interrupted the course of radiotherapy because of a quick worsening of general clinical condition. Conclusions These preliminary results stated that volumetric modulated arc therapy in locally advanced head and neck cancers is feasible and effective, with acceptable toxicities.

  17. Semitransparent curtains for control of optical radiation hazards

    Science.gov (United States)

    Sliney, D. H.; Moss, C. E.; Miller, C. G.; Stephens, J. B.

    1981-01-01

    The purposes and functions of semitransparent eye protective curtains are analyzed. Based upon this analysis, functional requirements are developed, and design requirements are specified for optimum curtains to be used with open arc welding and arc cutting processes. Such curtains also protect against other high intensity broad-spectral-band sources such as compact arc lamps. The requirements for filtering out hazardous UV radiation and blue light must be balanced against the need for transparency in the visible spectrum and the need for reduced glare. Infrared attenuation is shown to be of very little importance.

  18. How near, how far? Adaptive radiation in mammals and birds on various islands

    NARCIS (Netherlands)

    Hoek Ostende, van den L.W.; Locatelli, E.; Meijer, H.J.M.

    2011-01-01

    Many factors control radiations on islands, but some general patterns do emerge. Bird radiations are mostly found on oceanic archipelagos far from the continental coast line. Mammal radiations are mostly know from island arcs, which are somewhat easier to reach though still isolated enough to allow

  19. PNW River Reach Files -- 1:100k Watercourses (arcs)

    Data.gov (United States)

    Pacific States Marine Fisheries Commission — This feature class includes the ARC features from the 2001 version of the PNW River Reach files Arc/INFO coverage. Separate, companion feature classes are also...

  20. Modeling Vacuum Arcs On Spacecraft Solar Panel Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Spacecraft charging and subsequent vacuum arcing poses a significant threat to satellites in LEO and GEO plasma conditions. Localized arc discharges can cause a...

  1. Obtaining Solutions to Radiation-And Plasma Induced FAilure Modes From Physics

    Science.gov (United States)

    Frederickson, A.

    1998-01-01

    A number of performance-limiting spacecraft problems will be qualitatively discussed: Spacecraft Charging, Deep Dielectric Charging, Solar Cell Arcing, Antenna Sparking, High Voltage Power Shorts, Radiation-induced Defects in Semiconductors, and Degradation of Electronic Devices.

  2. Soundness of Timed-Arc Workflow Nets

    DEFF Research Database (Denmark)

    Mateo, Jose Antonio; Srba, Jiri; Sørensen, Mathias Grund

    2014-01-01

    Analysis of workflow processes with quantitative aspects like timing is of interest in numerous time-critical applications. We suggest a workflow model based on timed-arc Petri nets and study the foundational problems of soundness and strong (time-bounded) soundness. We explore the decidability o...

  3. ArcAid Interactive Archery Assistant

    Directory of Open Access Journals (Sweden)

    Jeroen Vervaeke

    2015-12-01

    Full Text Available This paper describes the design process of a bow aiming system, called ArcAid, which is an interactive archery assistant. The main goal of ArcAid is to introduce a way for beginner Robin Hoods to learn the art of archery to its fullest. In order to achieve this goal, our smartphone-based design focuses on a fun and interactive learning process that gives constant feedback to the user on how to hit a certain goal. A SPIKE high- end laser sensor is used for the distance measurement and the smartphone’s accelerometer is used to define the angle of inclination. To measure the force on the arrow and the displacement of the string, a flex sensor is attached upon one of the arcs of the bow. All sensor data is processed in an Arduino Nano microprocessor and feedback to the user is given by a dedicated smartphone app. In this paper, we mainly focus on the construction, mechanics and electronics of the ArcAid bow and on the design of the mobile app, which is the game controller. Furthermore, we briefly discuss some future development ideas.

  4. Remote electrical arc suppression by laser filamentation

    CERN Document Server

    Schubert, Elise; Kasparian, Jérôme; Wolf, Jean-Pierre

    2015-01-01

    We investigate the interaction of narrow plasma channels formed in the filamentation of ultrashort laser pulses, with a DC high voltage. The laser filaments prevent electrical arcs by triggering corona that neutralize the high-voltage electrodes. This phenomenon, due to the electric field modulation and free electron release around the filament, opens new prospects to lightning and over-voltage mitigation.

  5. Hypergravity effects on glide arc plasma

    NARCIS (Netherlands)

    Šperka, J.; Souček, P.; van Loon, J.J.W.A.; Dowson, A.; Schwarz, C.; Krause, J.; Kroesen, G.; Kudrle, V.

    2013-01-01

    The behaviour of a special type of electric discharge - the gliding arc plasma - has been investigated in hypergravity (1g-18g) using the Large Diameter Centrifuge (LDC) at ESA/ESTEC. The discharge voltage and current together with the videosignal from a fast camera have been recorded during the exp

  6. Arc discharge sliding over a conducting surface

    NARCIS (Netherlands)

    Goor, van F.A.; Mitko, S.V.; Ochkin, V.N.; Paramonov, A.P.; Witteman, W.J.

    1997-01-01

    Results of experimental and theoretical studies of the arc discharge which slides over the surface of a conductor are reported. Experiments were performed in air and argon ambients at various pressures. It is found that the velocity of the discharge plasma front depends linearly on the strength of t

  7. Stability of alternating current gliding arcs

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Salewski, Mirko; Leipold, Frank;

    2014-01-01

    that the critical length can be increased by increasing the AC frequency, decreasing the serial resistance and lowering the gas flow rate. The predicted dependence of gas flow rate on the arc length is experimentally demonstrated. The gap width is varied to study an optimal electrode design, since the extended non...

  8. First NIF ARC target shot results

    Science.gov (United States)

    Chen, Hui; di Nicola, P.; Hermann, M.; Kalantar, D.; Martinez, D.; Tommasini, R.; NIF ARC Team

    2015-11-01

    The commissioning of the Advanced Radiographic Capability (ARC) laser system in the National Ignition Facility (NIF) is currently in progress. ARC laser is designed to ultimately provide eight beamlets with pulse duration adjustable from 1 to 50 ps, and energies up to 1.7 kJ per beamlet. ARC will add critical capability for the NIF facility for creating precision x-ray backlighters needed for many current NIF ICF and HED experiments. ARC can also produce MeV electrons and protons for new science experiment on NIF. In the initial set of experiments, 4 of the 8 beamlets are being commissioned up to 1 kJ per beam at 30 ps pulse length using foil and wire targets. X-ray energy distribution, spot size and pulse duration are measured using various diagnostics. This talk will describe the shot setup and results. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  9. Gas tungsten arc welder with electrode grinder

    Science.gov (United States)

    Christiansen, David W.; Brown, William F.

    1984-01-01

    A welder for automated closure of fuel pins by a gas tungsten arc process in which a rotating length of cladding is positioned adjacent a welding electrode in a sealed enclosure. An independently movable axial grinder is provided in the enclosure for refurbishing the used electrode between welds.

  10. Roadmap for the ARC Grid Middleware

    DEFF Research Database (Denmark)

    Kleist, Josva; Eerola, Paula; Ekelöf, Tord

    2006-01-01

    The Advanced Resource Connector (ARC) or the NorduGrid middleware is an open source software solution enabling production quality computational and data Grids, with special emphasis on scalability, stability, reliability and performance. Since its first release in May 2002, the middleware is depl...

  11. Nonlinear Study of Industrial Arc Spring Dampers

    DEFF Research Database (Denmark)

    Lahriri, Said; Santos, Ilmar; Hartmann, Henning

    2011-01-01

    The objective of this paper is to present a numerical approach for analyzing parameter excited vibrations on a gas compressor, induced by the nonlinear characteristic of the arc spring feature of certain designs of squeeze film dampers, SFDs. The behavior of the journal is studied in preparation ...

  12. Dosimetric study on the volumetric modulated arc therapy in the radiotherapy of esophageal cancer%容积调强技术在食管癌放疗中的剂量学研究

    Institute of Scientific and Technical Information of China (English)

    余建荣; 古定标; 李珍; 郭纪慈

    2016-01-01

    目的:研究旋转容积调强VMAT与固定野调强IMRT在食管癌放疗中的剂量学差异。方法2014年6月~2015年8月入组食管癌患者30例。用瓦利安Eclipse10.0计划系统分别设计单弧VMAT(Arc1)、双弧VMAT(Arc2)、和9野IMRT计划。比较三组计划在平均剂量体积直方图、靶区剂量覆盖率、危及器官和正常组织保护等方面的剂量学差异,并比较三组计划的总机器跳数(MU)和治疗时间。结果 VMAT(Arc2)靶区剂量分布均匀性(HI)和矩形度(CI)较其他两种要好(P<0.05)。危及器官方面:VMAT(Arc1)与VMAT(Arc2)比较,VMAT(Arc2)对双肺、脊髓Dmax保护优于VMAT(Arc1);VMAT(Arc2)、与IMRT 9野比较,VMAT(Arc2)对心脏Dmean、脊髓Dmax保护优于IMRT 9野;治疗时间方面:VMAT(Arc1)时间最短,需时90s,VMAT(Arc2)所需时间190~200s,IMRT 9野平均所需时间680s。结论 VMAT(Arc1)、VMAT(Arc2)、与IMRT 9野三种计划都满足临床要求。对于瓦利安Eclipse10.0计划系统VMAT(Arc2)临床使用上较普遍。%ObjectiveTo explore the dosimetric differences between volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) in the radiotherapy of esophageal cancer. Methods30 patients with esophageal cancers during June 2014 and August 2015 were recruited. The single arc VMAT (Arc 1) plan, double arc VMAT (Arc2) plan, and IMRT 9 fields plan were designed by Varian Eclipse 10.0 planning system. The dosimetric differences of average dose volume histogram, target section dose distribution, organ damage, and normal tissue protections of the three plans were compared. The total monitor unit (MU) numbers and treatment time of the three plans were compared.ResultsThe homogeneity index (HI) and conformal index (CI) of VMAT (Arc2) plan were better than the other two plans (P<0.05). In terms of organ damage, the VMAT (Arc2) plan's Dmax protections of

  13. Supersonic Vortex Gerdien Arc with Magnetic Thermal Insulation

    Science.gov (United States)

    Winterberg, F.

    1988-02-01

    Temperatures up to ~ 5 x 104 oK have been obtained with water vortex Gerdien arcs, and temperatures of ~ 105oK have been reached in hydrogen plasma arcs with magnetic thermal insulation through an externally applied strong magnetic field. It is suggested that a further increase in arc temperatures up to 106oK can conceivably be attained by a combination of both techniques, using a Gerdien arc with a supersonic hydrogen gas vortex.

  14. H2O and CO2 in magmas from the Mariana arc and back arc systems

    Science.gov (United States)

    Newman, Sally; Stolper, Edward; Stern, Robert

    2000-05-01

    We examined the H2O and CO2 contents of glasses from lavas and xenoliths from the Mariana arc system, an intraoceanic convergent margin in the western Pacific, which contains an active volcanic arc, an actively spreading back arc basin, and active behind-the-arc cross-chain volcanoes. Samples include (1) glass rims from Mariana arc, Mariana trough, and cross-chain submarine lavas; (2) glass inclusions in arc and trough phenocrysts; and (3) glass inclusions from a gabbro + anorthosite xenolith from Agrigan (Mariana arc). Glass rims of submarine arc lavas contain 0.3-1.9 wt % H2O, and CO2 is below detection limits. Where they could be compared, glass inclusions in arc phenocrysts contain more H2O than their host glasses; most arc glasses and phenocryst inclusions contain no detectable CO2, with the exception of those from a North Hiyoshi shoshonite, which contains 400-600 ppm. The glass inclusions from the Agrigan xenolith contain 4-6% H2O, and CO2 is below the detection limit. Glasses from the cross-chain lavas are similar to those from the arc: H2O contents are 1.4-1.7 wt %, and CO2 is below detection limits. Volatile contents in Mariana trough lava glass rims are variable: 0.2-2.8 wt % H2O and 0-300 ppm CO2. Glass inclusions from trough phenocrysts have water contents similar to the host glass, but they can contain up to 875 ppm CO2. Volatile contents of melt inclusions from trough and arc lavas and from the xenolith imply minimum depths of crystallization of ~1-8 km. H2O and CO2 contents of Mariana trough glasses are negatively correlated, indicating saturation of the erupting magma with a CO2-H2O vapor at the pressure of eruption (~400 bars for these samples), with the vapor ranging from nearly pure CO2 at the CO2-rich end of the glass array to nearly pure H2O at the H2O-rich end. Degassing of these magmas on ascent and eruption leads to significant loss of CO2 (thereby masking preeruptive CO2 contents) but minimal disturbance of preeruptive H2O contents. For

  15. Anatomy of Intra-Oceanic Arc Systems

    Science.gov (United States)

    Stern, R. J.

    2007-12-01

    Intra-oceanic arc systems (IOAS) are ultimately embedded in orogenic belts and added to the continental crust. Reconstructing fossil IOASs in collision zones requires understanding the salient features of a typical IOAS. IOASs have the relative dimensions of tagliatelle (flat) pasta: much wider (~250 km) than thick (10-30 km), much longer (1000's of km) than wide. IOASs begin to form when subduction begins, either spontaneously (SNSZ) or by forced convergence (INSZ). For SNSZ, IOASs start as broad zones of seafloor spreading associated with subsidence of the adjacent lithosphere, whereas INSZ IOASs are built on trapped crust. IOAS magmatism manifests the evolution of its subduction zone and indirectly the breadth of the subducted ocean. Two stages in SNSZ IOAS magmato-tectonic evolution exist: infancy and maturity. Infancy lasts 5-10 Ma and results in broad zones of seafloor spreading of tholeiite/boninite; this becomes forearc for the mature IOAS and is emplaced as ophiolite during collision (subduction zone failure). Arc maturity begins with true subduction, as the subducted slab reaches depths ~130 km, focusing magmatism to begin building the magmatic arc ~200km away from the trench and allowing the forearc to cool and hydrate. Mature magmatic arcs mostly yield low-K tholeiitic and medium-K calc-alkaline magmas. Magmatic focusing begins crustal thickening beneath the magmatic arc, at ~500m/Ma for the Izu-Bonin-Mariana IOAS. No systematic compositional evolution to more LIL-enriched primitive magmas occurs once IOAS maturity is reached, except when upper plate stress regime (BAB formation, strike- slip faulting) or the nature of subducted material (more/different sediments, young oceanic crust) changes. Thickening is accompanied by processing of crust beneath the magmatic arc, with progressive differentiation into upper volcanic, middle tonalitic, and lower mafic layers, producing an increasingly effective density filter for magma ascent. Crustal layer formation

  16. The arc arises: The links between volcanic output, arc evolution and melt composition

    Science.gov (United States)

    Brandl, Philipp A.; Hamada, Morihisa; Arculus, Richard J.; Johnson, Kyle; Marsaglia, Kathleen M.; Savov, Ivan P.; Ishizuka, Osamu; Li, He

    2017-03-01

    Subduction initiation is a key process for global plate tectonics. Individual lithologies developed during subduction initiation and arc inception have been identified in the trench wall of the Izu-Bonin-Mariana (IBM) island arc but a continuous record of this process has not previously been described. Here, we present results from International Ocean Discovery Program Expedition 351 that drilled a single site west of the Kyushu-Palau Ridge (KPR), a chain of extinct stratovolcanoes that represents the proto-IBM island arc, active for ∼25 Ma following subduction initiation. Site U1438 recovered 150 m of oceanic igneous basement and ∼1450 m of overlying sediments. The lower 1300 m of these sediments comprise volcaniclastic gravity-flow deposits shed from the evolving KPR arc front. We separated fresh magmatic minerals from Site U1438 sediments, and analyzed 304 glass (formerly melt) inclusions, hosted by clinopyroxene and plagioclase. Compositions of glass inclusions preserve a temporal magmatic record of the juvenile island arc, complementary to the predominant mid-Miocene to recent activity determined from tephra layers recovered by drilling in the IBM forearc. The glass inclusions record the progressive transition of melt compositions dominated by an early 'calc-alkalic', high-Mg andesitic stage to a younger tholeiitic stage over a time period of 11 Ma. High-precision trace element analytical data record a simultaneously increasing influence of a deep subduction component (e.g., increase in Th vs. Nb, light rare earth element enrichment) and a more fertile mantle source (reflected in increased high field strength element abundances). This compositional change is accompanied by increased deposition rates of volcaniclastic sediments reflecting magmatic output and maturity of the arc. We conclude the 'calc-alkalic' stage of arc evolution may endure as long as mantle wedge sources are not mostly advected away from the zones of arc magma generation, or the rate of

  17. Electric-arc synthesis of soot with high content of higher fullerenes in parallel arc

    Science.gov (United States)

    Dutlov, A. E.; Nekrasov, V. M.; Sergeev, A. G.; Bubnov, V. P.; Kareev, I. E.

    2016-12-01

    Soot with a relatively high content of higher fullerenes (C76, C78, C80, C82, C84, C86, etc.) is synthesized in a parallel arc upon evaporation of pure carbon electrodes. The content of higher fullerenes in soot extract amounts to 13.8 wt % when two electrodes are simultaneously burnt in electric-arc reactor. Such a content is comparable with the content obtained upon evaporation of composite graphite electrodes with potassium carbonate impurity.

  18. Bulk arc strain, crustal thickening, magma emplacement, and mass balances in the Mesozoic Sierra Nevada arc

    Science.gov (United States)

    Cao, Wenrong; Paterson, Scott; Saleeby, Jason; Zalunardo, Sean

    2016-03-01

    Quantifying crustal deformation is important for evaluating mass balance, material transfer, and the interplay between tectonism and magmatism in continental arcs. We present a dataset of >650 finite strain analyses compiled from published works and our own studies with associated structural, geochronologic, and geobarometric information in central and southern Sierra Nevada, California, to quantify the arc crust deformation. Our results show that Mesozoic tectonism results in 65% arc-perpendicular bulk crust shortening under a more or less plane strain condition. Mesozoic arc magmatism replaced ∼80% of this actively deforming arc crust with plutons requiring significantly greater crustal thickening. We suggest that by ∼85 Ma, the arc crust thickness was ∼80 km with a 30-km-thick arc root, resulting in a ∼5 km elevation. Most tectonic shortening and magma emplacement must be accommodated by downward displacements of crustal materials into growing crustal roots at the estimated downward transfer rate of 2-13 km/Myr. The downward transfer of crustal materials must occur in active magma channels, or in "escape channels" in between solidified plutons that decrease in size with time and depth resulting in an increase in the intensity of constrictional strain with depth. We argue that both tectonism and magmatism control the thickness of the crust and surface elevation with slight modification by surface erosion. The downward transported crustal materials initially fertilize the MASH zone thus enhancing to the generation of additional magmas. As the crustal root grows it may potentially pinch out and cool the mantle wedge and thus cause reduction of arc magmatism.

  19. Evaluation of the clinical usefulness of modulated Arc treatment

    CERN Document Server

    Lee, Young Kyu; Kim, Yeon Sil; Choi, Byung Ock; Nam, Sang Hee; Park, Hyeong Wook; Kim, Shin Wook; Shin, Hun Joo; Lee, Jae Choon; Kim, Ji Na; Park, Sung Kwang; Kim, Jin Young; Kang, Young-Nam

    2015-01-01

    The purpose of this study is to evaluate the clinical usefulness of modulated arc (mARC) treatment techniques. The mARC treatment plans of the non-small cell lung cancer (NSCLC) patients were performed in order to verify the clinical usefulness of mARC. A pre study was conducted to find the most competent plan condition of mARC treatment and the usefulness of mARC treatment plan was evaluated by comparing it with the other Arc treatment plans such as Tomotherapy and RapidArc. In the case of mARC, the optimal condition for the mARC plan was determined by comparing the dosimetric performance of the mARC plans with the use of various parameters. The various parameters includes the photon energies (6 MV, 10 MV), optimization point angle (6{\\deg}-10{\\deg} intervals), and total segment number (36-59 segment). The best dosimetric performance of mARC was observed at 10 MV photon energy and the point angle 6 degree, and 59 segments. The each treatment plans of three different techniques were compared with the followin...

  20. Unstable Behavior of Anodic Arc Discharge for Synthesis of Nanomaterials

    Science.gov (United States)

    Gershman, Sophia; Raitses, Yevgeny

    2016-09-01

    Fast imaging and electrical current measurements reveal unstable behavior of the carbon arc discharge for synthesis of nanomaterials. The arc column and the arc attachment region to the anode move in a somewhat sporadic way with a characteristic time in a 10-3 sec range. The arc exhibits a negative differential resistance before the arc motion occurs. A physical mechanism is proposed based on the thermal processes in the arc plasma region interacting with the ablating anode which leads to the shift of the arc to a new anode region. According to the transient heat transfer analysis, the time needed to heat a new anode region is also in a 10-3 sec range. For a 0.6 cm diameter anode used in our experiments, this time yields a frequency of about 200-300 Hz, comparable to the measured frequency of the arc motion. The voltage and current measurements show oscillations with a similar characteristic frequency. The thermal model is indirectly supported by the measured negative differential resistance of the arc discharge during arc oscillations. The observed unstable behavior of the arc may be responsible for the mixing of the flow of nanoparticles during the synthesis of nanoparticles leading to poor selectivity typical for the arc synthesis. The work was supported by US DOE under Contract No. DE-AC02-09CH11466.

  1. 多发脑转移癌容积弧形调强与适形调强的剂量学对比研究%Comparative study of dosimetry between volumetric-modulated arc therapy and intensity-modulated radiation therapy for brain metastases

    Institute of Scientific and Technical Information of China (English)

    龙斌; 谢悦; 蒋勇; 李淑杰; 邱大; 王颖

    2015-01-01

    Objective To compare volumetric‐modulated arc therapy(VMAT) with intensity‐modulated radiation therapy (IMRT) for brain metastases with regard to the dosimetric character .Methods Sixty patients who were diagnosed with brain me‐tastases were included in this study .The target area received two dose levels using late addition amount technique ,WBRT (30 Gy/10 F) with following addition (20 Gy/10 F) to 59 Gy .For a fair comparison ,VMAT and IMRT treatment plans were respectively designed for every patient with the same dosimetric constraints .Dosimetric comparisons between VMAT and IMRT plans were ana‐lyzed to evaluate :target coverage and homogeneity ,conformity of PTV ;sparing of OARs ;monitor units (MUs) .Results Two treatment plans all reached the treatment need .When compared with IMRT ,there was no significant difference in Dmean of eyeball , len ,optic never ,visual chiasma ,parotid ,brain stem ,and external auditory canal of VMAT (P>0 .05) .The Dmax of eyeball ,len ,pa‐rotid ,and external auditory canal of VMAT were lower than that in IMRT group (P<0 .05) .The VMAT group has the less MUs (P=0 .017) and less treatment time .Conclusion VMAT can reach the big‐dose radiotherapy need on brain metastases clinically . There are no significant diffference between VMAT and IMRT on Dmax ,Dmean ,CI ,and HI .The Dmax of eyeball ,len ,parotid ,and external auditory canal of VMAT were lower than that in IMRT group .The VMAT can reduce the radiotherapy time .%目的:探讨多发脑转移癌在治疗中容积弧形调强放疗(VMAT)与适形调强放疗(IMRT)的剂量学特点。方法选择60例确诊的多发脑转移癌患者纳入本研究。所有患者均采用全脑放疗加肿瘤靶区后期加量技术给予处方剂量,全脑放疗30 Gy/10F ,病灶加量20 Gy/10F至生物学剂量59 Gy。每例患者采用同样的剂量学条件限制,分别进行两弧容积弧形调强计划与调强计划设计。通过其剂量学分析评估:

  2. Optimal planning strategy among various arc arrangements for prostate stereotactic body radiotherapy with volumetric modulated arc therapy technique

    Directory of Open Access Journals (Sweden)

    Kang Sang Won

    2017-03-01

    Full Text Available The aim of this study was to determine the optimal strategy among various arc arrangements in prostate plans of stereotactic body radiotherapy with volumetric modulated arc therapy (SBRT-VMAT.

  3. The physics of radiation therapy

    CERN Document Server

    Khan, Faiz M

    2009-01-01

    Dr. Khan's classic textbook on radiation oncology physics is now in its thoroughly revised and updated Fourth Edition. It provides the entire radiation therapy team—radiation oncologists, medical physicists, dosimetrists, and radiation therapists—with a thorough understanding of the physics and practical clinical applications of advanced radiation therapy technologies, including 3D-CRT, stereotactic radiotherapy, HDR, IMRT, IGRT, and proton beam therapy. These technologies are discussed along with the physical concepts underlying treatment planning, treatment delivery, and dosimetry. This Fourth Edition includes brand-new chapters on image-guided radiation therapy (IGRT) and proton beam therapy. Other chapters have been revised to incorporate the most recent developments in the field. This edition also features more than 100 full-color illustrations throughout.

  4. Effects of radiative transfer modelling on the dynamics of a propagating electrical discharge

    Energy Technology Data Exchange (ETDEWEB)

    Kahhali, Nicolas; Riviere, Philippe; Perrin, Marie-Yvonne; Soufiani, Anouar [Laboratoire EM2C, CNRS UPR 288, Ecole Centrale Paris, 92295 Chatenay-Malabry Cedex (France); Gonnet, Jean-Paul, E-mail: Anouar.Soufiani@em2c.ecp.f [Schneider Electric, Power Business, LV Arc Breaking-Modeling and Expertise Site 38 EQI Eybens, 38050 Grenoble Cedex 9 (France)

    2010-10-27

    A radiative transfer methodology is developed for the modelling of coupled radiation, hydrodynamic and electromagnetic phenomena in unsteady air plasma flows. Absorption spectra are discretized according to the distribution functions of the absorption coefficients resulting from different types of radiative transitions, and this spectral model is combined with the differential P{sub 1} approximation which is shown to predict quite accurately radiative source terms. The study of a propagating electrical arc in a 2D channel shows that radiative transfer modelling significantly affects the shape of the plasma and its dynamics. In particular, when compared with the results from the net emission coefficient method, the arc velocity is found to increase due to radiation absorption in the arc boundaries.

  5. Interaction of ARC and Daxx: A Novel Endogenous Target to Preserve Motor Function and Cell Loss after Focal Brain Ischemia in Mice

    Science.gov (United States)

    Donath, Stefan; An, Junfeng; Lee, Sabrina Lin Lin; Gertz, Karen; Datwyler, Anna Lena; Harms, Ulrike; Müller, Susanne; Farr, Tracy Deanne; Füchtemeier, Martina; Lättig-Tünnemann, Gisela; Lips, Janet; Foddis, Marco; Mosch, Larissa; Bernard, René; Grittner, Ulrike; Balkaya, Mustafa; Kronenberg, Golo; Dirnagl, Ulrich; Endres, Matthias

    2016-01-01

    The aim of this study was to explore the signaling and neuroprotective effect of transactivator of transcription (TAT) protein transduction of the apoptosis repressor with CARD (ARC) in in vitro and in vivo models of cerebral ischemia in mice. In mice, transient focal cerebral ischemia reduced endogenous ARC protein in neurons in the ischemic striatum at early reperfusion time points, and in primary neuronal cultures, RNA interference resulted in greater neuronal susceptibility to oxygen glucose deprivation (OGD). TAT.ARC protein delivery led to a dose-dependent better survival after OGD. Infarct sizes 72 h after 60 min middle cerebral artery occlusion (MCAo) were on average 30 ± 8% (mean ± SD; p = 0.005; T2-weighted MRI) smaller in TAT.ARC-treated mice (1 μg intraventricularly during MCAo) compared with controls. TAT.ARC-treated mice showed better performance in the pole test compared with TAT.β-Gal-treated controls. Importantly, post-stroke treatment (3 h after MCAo) was still effective in affording reduced lesion volume by 20 ± 7% (mean ± SD; p < 0.05) and better functional outcome compared with controls. Delayed treatment in mice subjected to 30 min MCAo led to sustained neuroprotection and functional behavior benefits for at least 28 d. Functionally, TAT.ARC treatment inhibited DAXX–ASK1–JNK signaling in the ischemic brain. ARC interacts with DAXX in a CARD-dependent manner to block DAXX trafficking and ASK1–JNK activation. Our work identifies for the first time ARC–DAXX binding to block ASK1–JNK activation as an ARC-specific endogenous mechanism that interferes with neuronal cell death and ischemic brain injury. Delayed delivery of TAT.ARC may present a promising target for stroke therapy. SIGNIFICANCE STATEMENT Up to now, the only successful pharmacological target of human ischemic stroke is thrombolysis. Neuroprotective pharmacological strategies are needed to accompany therapies aiming to achieve reperfusion. We describe that apoptosis

  6. Detecting stellar-wind bubbles through infrared arcs in HII regions

    CERN Document Server

    Mackey, Jonathan; Gvaramadze, Vasilii V; Mohamed, Shazrene; Langer, Norbert; Harries, Tim J

    2015-01-01

    Mid-infrared arcs of dust emission are often seen near ionizing stars within HII regions. A possible explanations for these arcs is that they could show the outer edges of asymmetric stellar wind bubbles. We use two-dimensional, radiation-hydrodynamics simulations of wind bubbles within HII regions around individual stars to predict the infrared emission properties of the dust within the HII region. We assume that dust and gas are dynamically well-coupled and that dust properties (composition, size distribution) are the same in the HII region as outside it, and that the wind bubble contains no dust. We post-process the simulations to make synthetic intensity maps at infrared wavebands using the TORUS code. We find that the outer edge of a wind bubble emits brightly at 24um through starlight absorbed by dust grains and re-radiated thermally in the infrared. This produces a bright arc of emission for slowly moving stars that have asymmetric wind bubbles, even for cases where there is no bow shock or any corresp...

  7. Global Delivery Models

    DEFF Research Database (Denmark)

    Manning, Stephan; Larsen, Marcus M.; Bharati, Pratyush

    2013-01-01

    This article examines antecedents and performance implications of global delivery models (GDMs) in global business services. GDMs require geographically distributed operations to exploit both proximity to clients and time-zone spread for efficient service delivery. We propose and empirically show...... digitalized services, time zones increasingly affect....

  8. Prediction of preterm delivery

    NARCIS (Netherlands)

    Wilms, F.F.

    2014-01-01

    Preterm delivery is in quantity and in severity an important issue in the obstetric care in the Western world. There is considerable knowledge on maternal and obstetric risk factors of preterm delivery. Of the women presenting with preterm labor, the majority is pregnant with a male fetus and in Cau

  9. Nanofocusing of electromagnetic radiation

    DEFF Research Database (Denmark)

    Gramotnev, D. K.; Bozhevolnyi, Sergey I.

    2014-01-01

    Nanofocusing of electromagnetic radiation, that is, reducing the cross sections of propagating optical modes far beyond the diffraction limit in dielectric media, can be achieved in tapered metal-dielectric waveguides that support surface plasmon-polariton modes. Although the main principles...... of nanofocusing were formulated over a decade ago, a deep theoretical understanding and conclusive experimental verification were achieved only a few years ago. These advances have spawned a variety of new important technological possibilities for the efficient delivery, control and manipulation of optical...... radiation on the nanoscale. Here, we present the underlying physical principles of radiation nanofocusing in metallic nanostructures, overview recent progress and major developments, and consider future directions and potential applications of this subfield of nano-optics....

  10. Driven Motion and Instability of an Atmospheric Pressure Arc

    Energy Technology Data Exchange (ETDEWEB)

    Max Karasik

    1999-12-01

    Atmospheric pressure arcs are used extensively in applications such as welding and metallurgy. However, comparatively little is known of the physics of such arcs in external magnetic fields and the mechanisms of the instabilities present. In order to address questions of equilibrium and stability of such arcs, an experimental arc furnace is constructed and operated in air with graphite cathode and steel anode at currents 100-250 A. The arc is diagnosed with a gated intensified camera and a collimated photodiode array, as well as fast voltage and current probes.

  11. THE PERIODIC CAPACITATED ARC ROUTING PROBLEM LINEAR PROGRAMMING MODEL,METAHEURISTIC AND LOWER BOUNDS

    Institute of Scientific and Technical Information of China (English)

    Feng CHU; Nacima LABADI; Christian PRINS

    2004-01-01

    The Periodic Capacitated Arc Routing Problem (PCARP) generalizes the well known NP-hard Capacitated Arc Routing Problem (CARP) by extending the single period to multi-period horizon.The Capacitated Arc Routing Problem (CARP) is defined on an undirected network in which a fleet of identical vehicles is based at a depot node. A subset of edges, called tasks, must be serviced by a vehicle. The CARP consists of determining a set of feasible vehicle trips that minimizes the total cost of traversed edges. The PCARP involves the assignment of tasks to periods and the determination of vehicles trips in each period, to minimize the total cost on the whole horizon. This new problem arises in various real life applications such as waste collection, mail delivery, etc. In this paper, a new linear programming model and preliminary lower bounds based on graph transformation are proposed. A meta-heuristic approach - Scatter Search (SS) is developed for the PCARP and evaluated on a large variety of instances.

  12. Radiation Therapy

    Science.gov (United States)

    Radiation therapy is a cancer treatment. It uses high doses of radiation to kill cancer cells and stop them from ... half of all cancer patients receive it. The radiation may be external, from special machines, or internal, ...

  13. On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery.

    Science.gov (United States)

    Pokhrel, Damodar; Sood, Sumit; McClinton, Christopher; Shen, Xinglei; Badkul, Rajeev; Jiang, Hongyu; Mallory, Matthew; Mitchell, Mellissa; Wang, Fen; Lominska, Christopher

    2017-01-01

    To retrospectively evaluate quality, efficiency, and delivery accuracy of volumetric-modulated arc therapy (VMAT) plans for single-fraction treatment of thoracic vertebral metastases using image-guided stereotactic body radiosurgery (SBRS) after RTOG 0631 dosimetric compliance criteria. After obtaining credentialing for MD Anderson spine phantom irradiation validation, 10 previously treated patients with thoracic vertebral metastases with noncoplanar hybrid arcs using 1 to 2 3D-conformal partial arcs plus 7 to 9 intensity-modulated radiation therapy beams were retrospectively re-optimized with VMAT using 3 full coplanar arcs. Tumors were located between T2 and T12. Contrast-enhanced T1/T2-weighted magnetic resonance images were coregistered with planning computed tomography and planning target volumes (PTV) were between 14.4 and 230.1cc (median = 38.0cc). Prescription dose was 16Gy in 1 fraction with 6MV beams at Novalis-TX linear accelerator consisting of micro multileaf collimators. Each plan was assessed for target coverage using conformality index, the conformation number, the ratio of the volume receiving 50% of the prescription dose over PTV, R50%, homogeneity index (HI), and PTV_1600 coverage per RTOG 0631 requirements. Organs-at-risk doses were evaluated for maximum doses to spinal cord (D0.03cc, D0.35cc), partial spinal cord (D10%), esophagus (D0.03cc and D5cc), heart (D0.03cc and D15cc), and lung (V5, V10, and maximum dose to 1000cc of lung). Dose delivery efficiency and accuracy of each VMAT-SBRS plan were assessed using quality assurance (QA) plan on MapCHECK device. Total beam-on time was recorded during QA procedure, and a clinical gamma index (2%/2mm and 3%/3mm) was used to compare agreement between planned and measured doses. All 10 VMAT-SBRS plans met RTOG 0631 dosimetric requirements for PTV coverage. The plans demonstrated highly conformal and homogenous coverage of the vertebral PTV with mean HI, conformality index, conformation number, and R50

  14. Radiation dosimetry

    CERN Document Server

    Hine, Gerald J; Hine, Gerald J

    1956-01-01

    Radiation Dosimetry focuses on the advancements, processes, technologies, techniques, and principles involved in radiation dosimetry, including counters and calibration and standardization techniques. The selection first offers information on radiation units and the theory of ionization dosimetry and interaction of radiation with matter. Topics include quantities derivable from roentgens, determination of dose in roentgens, ionization dosimetry of high-energy photons and corpuscular radiations, and heavy charged particles. The text then examines the biological and medical effects of radiation,

  15. Series and parallel arc-fault circuit interrupter tests.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean; Fresquez, Armando J.; Gudgel, Bob; Meares, Andrew

    2013-07-01

    While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by opening the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.

  16. BASIC THEORY AND APPLICATIONS OF WELDING ARC SPECTRAL INFORMATION

    Institute of Scientific and Technical Information of China (English)

    LI Junyue; XUE Haitao; LI Huan; SONG Yonglun

    2007-01-01

    Welding arc spectral information is a rising welding Information source. In some occasion, it can reflect many physical phenomena of welding process and solve many problems that cannot be done with arc electric information, acoustic information and other arc information. It is of important significance in developing automatic control technique of welding process and other similar process. Many years study work on welding arc spectral information of the anthor are discussed from three aspects of theory, method and application. Basic theory, view and testing methods of welding arc spectral information has been put forward. In application aspects, many applied examples, for example, monitoring of harmful gases in arc (such as hydrogen and nitrogen) with the method of welding arc spectral information; welding arc spectral imaging of thc welding pool which is used in automatic seam tracking; controlling of welding droplet transfer with welding arc spectral information and so on, are introduced. Especially, the successful application in real time controlling of welding droplet transfer in pulsed GMAW is introduced too. These application examples show that the welding arc spectral information has great applied significance and development potentialities. These content will play an important role in applying and spreading welding arc spectral information technology.

  17. NTWV-based sensing keyhole dimension in plasma arc welding

    Institute of Scientific and Technical Information of China (English)

    Jia Chuanbao; Wu Chuansong; Zhang Yuming

    2008-01-01

    During stable keyhole plasma arc welding, the pilot arc and the transferred arc exist at the meantime, and the arcs can be considered as a composition of two parts inside and outside the nozzle, respectively. Under the mechanical constriction and thermal contraction effects, the inside arc has certain arc length, electron density and arc profile etc. Inducing constant tungsten-to-nozzle voltage. However, the arc outside the nozzle diverges at about 5 degrees and has certain characteristics similar to the free arcs. The nozzle-to-workpiece voltage (NTWV) depends mainly on the length of the arc, which gets bigger as increasing of the weld penetration and keyhole size. The NTWV sensor is developed for monitoring NTWV in real time. The welding experiments are designed to get different penetrations and keyhole sizes. It is found that as the weld penetration and the keyhole size increase, NTWV also increases linearly. The NTWV signals can be used as the feedback variable in automatic control of keyhole plasma arc welding.

  18. Trends In Materials Processing With Laser Radiation

    Science.gov (United States)

    Herziger, G.; Kreutz, E. W.

    1989-04-01

    The objectives of reactive chemical and nonreactive thermal processing with laser radiation are outlined giving indication that processing with laser radiation is governed by a hierarchy of time constants originating from photon-matter interaction, phase transition dynamics, laser source excitation fluctuations,, and optical feedback in combination with the influence of beam delivery systems, processing/shielding gas flow configurations, robotics, production lines and environment. The minimization of losses by heat flow, reflection and transmission and the stringent need for quality assurance require as first approach the control of processing, which is mainly due to the capability of laser radiation source. The current status of laser radiation sources is reported giving information on the state of the art of processing with laser radiation in combination with subsequent demonstration of future trends and developments with respect to radiation sources, beam delivery, beam shaping, materials, processing and quality assurance.

  19. Trends in materials processsing with laser radiation

    Science.gov (United States)

    Herziger, Gerd; Kreutz, Ernst W.

    1989-03-01

    The objectives of reactive chemical and nonreactive thermal processing with laser radiation are outlined giving indication that processing with laser radiation is governed by a hierarchy of time constants originating from photon-matter interaction, phase transition dynamics, laser source excitation fluctuations, and optical feedback in combination with the influence of beam delivery systems, processing/shielding gas flow configurations, robotics, production lines and environment. The minimization of losses by heat flow, reflection and transmission and the stringent need for quality assurance require as first approach the control of processing, which is mainly due to the capability of laser radiation source. The current status of laser radiation sources is reported giving information on the state of the art of processing with laser radiation in combination with subsequent demonstration of future trends and developments with respect to radiation sources, beam delivery, beam shaping, materials, processing and quality assurance.

  20. Minimum-fuel rocket trajectories involving intermediate-thrust arcs

    Science.gov (United States)

    Breakwell, J. V.; Dixon, J. F.

    1975-01-01

    The optimal trajectories in the neighborhood of an optimal intermediate-thrust arc are investigated for the minimum-fuel orbit rendezvous problem with fixed specific impulse. Since such an arc is singular, the thrust acceleration magnitude being the singular control component, a second-variation analysis leads to the identification of a field of neighboring, singular arcs in a state space of dimension four rather than six, provided that a suitable Jacobi condition is met. A given neighboring initial six-dimensional state vector does not generally lie on a neighboring singular arc, and junction onto the appropriate singular arc must be accomplished by a short period of strong variations in the acceleration. The neighboring singular arc meets the final condition in 4 dimensions, rather than 6 dimensions, and rendezvous must be completed by another, terminal short period of strong variations in the acceleration. Implications for midcourse guidance near a singular arc are discussed.

  1. Discharge Characteristics of DC Arc Water Plasma for Environmental Applications

    Institute of Scientific and Technical Information of China (English)

    LI Tianming; Sooseok CHOI; Takayuki WATANABE

    2012-01-01

    A water plasma was generated by DC arc discharge with a hafnium embedded rodtype cathode and a nozzle-type anode. The discharge characteristics were examined by changing the operation parameter of the arc current. The dynamic behavior of the arc discharge led to significant fluctuations in the arc voltage and its frequency. Analyses of the high speed image and the arc voltage waveform showed that the arc discharge was in the restrike mode and its frequency varied within several tens of kilohertz according to the operating conditions. The larger thermal plasma volume was generated by the higher flow from the forming steam with a higher restrike frequency in the higher arc current conditions. In addition, the characteristics of the water plasma jet were investigated by means of optical emission spectroscopy to identify the abundant radicals required in an efficient waste treatment process.

  2. SU-E-T-538: Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, R; Zhan, L; Osei, E [Grand River Hospital, Kitchener, ON (Canada)

    2015-06-15

    Purpose: Dose distributions of RapidArc Plan can be quite different from standard 3D conformal radiation therapy. SBRT plans can be optimized with high conformity or mimic the 3D conformal treatment planning with very high dose in the center of the tumor. This study quantifies the dosimetric differences among 3D conformal plan; flattened beam and FFF beam RapidArc Plans for lung SBRT. Methods: Five lung cancer patients treated with 3D non-coplanar SBRT were randomly selected. All the patients were CT scanned with 4DCT to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. The prescription dose was 48 Gy in 4 fractions. The PTV coverage was optimized by two groups of objective function: one with high conformity, another mimicking 3D conformal dose distribution with high dose in the center of PTV. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using four full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. Results: All the RapidArc plans with flattened beam and FFF beam had similar results for the PTV and OARs. For the high conformity optimization group, The DVH of PTV exhibited a steep dose fall-off outside the PTV compared to the 3D non-coplanar plan. However, for the group mimicking the 3D conformal target dose distribution, although the PTV is very similar to the 3D conformal plan, the ITV coverage is better than 3D conformal plan. Conclusion: Due to excellent clinical experiences of 3D conformal SBRT treatment, the Rapid Arc optimization mimicking 3D conformal planning may be suggested for clinical use.

  3. Numerical modeling of transferred arc melting bath heating; Modelisation numerique du chauffage de bains par arc transfere

    Energy Technology Data Exchange (ETDEWEB)

    Bouvier, A. [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches; Trenty, L.; Guillot, J.B. [Ecole Centrale de Paris, Laboratoire EM2C. CNRS, 92 - Chatenay-Malabry (France); Delalondre, C. [Electricite de France (EDF), 78 - Chatou (France). Direction des Etudes et Recherches

    1997-12-31

    This paper presents the modeling of a transferred electric arc inside a bath of melted metal. After a recall of the context of the study, the problem of the modeling, which involves magnetohydrodynamic coupling inside the arc and the bath, is described. The equations that govern the phenomena inside the arc and the bath are recalled and the approach used for the modeling of the anode region of the arc is explained using a 1-D sub-model. The conditions of connection between arc and bath calculations are explained and calculation results obtained with a 200 kW laboratory furnace geometry are presented. (J.S.) 8 refs.

  4. Plasma Arc Augmented CO2 laser welding

    DEFF Research Database (Denmark)

    Bagger, Claus; Andersen, Mikkel; Frederiksen, Niels

    2001-01-01

    In order to reduce the hardness of laser beam welded 2.13 mm medium strength steel CMn 250, a plasma arc has been used simultaneously with a 2.6 kW CO2 laser source. In a number of systematic laboratory tests, the plasma arc current, plasma gas flow and distance to the laser source were varied...... with all laser parameters fixed. The welds were quality assessed and hardness measured transversely to the welding direction in the top, middle and root of the seam. In the seams welded by laser alone, hardness values between 275 and 304 HV1 were measured, about the double of the base material, 150 HV1...

  5. Examining properties of arc sprayed nanostructured coatings

    Directory of Open Access Journals (Sweden)

    A. Czupryński

    2016-04-01

    Full Text Available The article presents the results of examining properties of arc sprayed coating obtained with nano-alloy on the iron matrix with a high amount of fine carbide precipitates sprayed on non-alloyed steel plates intended for high temperature operation. Powder metal cored wire EnDOtec DO*390N 1,6 mm diameter, was used to produce, dense, very high abrasion and erosion resistant coatings approx. 1,0 mm thick. Nano-material coatings characterization was done to determine abrasion resistance, erosion resistance, adhesion strength, hardness as well as metallographic examinations. Results have proved high properties of arc sprayed nano-material coatings and have shown promising industrial applications.

  6. A pulsed cathodic arc spacecraft propulsion system

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, P R C; Bilek, M M M; Tarrant, R N; McKenzie, D R [School of Physics, University of Sydney, NSW 2006 Australia (Australia)

    2009-11-15

    We investigate the use of a centre-triggered cathodic arc as a spacecraft propulsion system that uses an inert solid as a source of plasma. The cathodic vacuum arc produces almost fully ionized plasma with a high exhaust velocity (>10{sup 4} m s{sup -1}), giving a specific impulse competitive with other plasma or ion thrusters. A centre trigger design is employed that enables efficient use of cathode material and a high pulse-to-pulse repeatability. We compare three anode geometries, two pulse current profiles and two pulse durations for their effects on impulse generation, energy and cathode material usage efficiency. Impulse measurement is achieved through the use of a free-swinging pendulum target constructed from a polymer material. Measurements show that impulse is accurately controlled by varying cathode current. The cylindrical anode gave the highest energy efficiency. Cathode usage is optimized by choosing a sawtooth current profile. There is no requirement for an exhaust charge neutralization system.

  7. Hybrid Arc Cell Studies: Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Berg J. S.

    2012-09-28

    I report on the status, at the end of FY12, of the studies of an arc cell for a hybrid synchrotron accelerating from 375 GeV/c to 750 GeV/c in momentum. Garren produced a complete lattice that gives a good outline of the structure of a hybrid synchrotron lattice. It is, however, lacking in some details: it does not maintain a constant time of flight, it lacks chromaticity correction, its cell structure is not ideal for removing aberrations from chromaticity correction, and it probably needs more space between magnets. I have begun studying cell structures for the arc cells to optimize the lattice performance and cost. I present some preliminary results for two magnets per half cell. I then discuss difficulties encountered, some preliminary attempts at resolving them, and the future plans for this work.

  8. Filtered cathodic arc deposition apparatus and method

    Science.gov (United States)

    Krauss, Alan R.

    1999-01-01

    A filtered cathodic arc deposition method and apparatus for the production of highly dense, wear resistant coatings which are free from macro particles. The filtered cathodic arc deposition apparatus includes a cross shaped vacuum chamber which houses a cathode target having an evaporable surface comprised of the coating material, means for generating a stream of plasma, means for generating a transverse magnetic field, and a macro particle deflector. The transverse magnetic field bends the generated stream of plasma in the direction of a substrate. Macro particles are effectively filtered from the stream of plasma by traveling, unaffected by the transverse magnetic field, along the initial path of the plasma stream to a macro particle deflector. The macro particle deflector has a preformed surface which deflects macro particles away from the substrate.

  9. Passive Visual Sensing in Automatic Arc Welding

    DEFF Research Database (Denmark)

    Liu, Jinchao

    For decades much work has been devoted to the research and development of automatic arc welding systems. However, it has remained a challenging problem. Besides the very complex arc welding process itself, the lack of ability to precisely sense the welding process, including the seam geometry...... industrial solutions for seam detection such as using laser scanners suer from several limitations. For instance, it must be positioned some distance ahead to the molten pool and may cause problem when dealing with shiny surfaces. Existing techniques for weld pool sensing mostly rely on auxiliary light...... on the weld pool and the nearby seam as the feedback to adjust the welding torch and/or welding parameters. It is an attractive idea from both academic and industrial point of view to develop a vision system without using any auxiliary light sources which can nevertheless extract relevant information. However...

  10. The singing arc: the oldest memristor?

    CERN Document Server

    Ginoux, Jean-Marc

    2014-01-01

    On April 30th 2008, the journal Nature announced that the missing circuit element, postulated thirty-seven years before by Professor Leon O. Chua has been found. Thus, after the capacitor, the resistor and the inductor, the existence of a fourth fundamental element of electronic circuits called "memristor" was established. In order to point out the importance of such a discovery, the aim of this article is first to propose an overview of the manner with which the three others have been invented during the past centuries. Then, a comparison between the main properties of the singing arc, i.e. a forerunner device of the triode used in Wireless Telegraphy, and that of the memristor will enable to state that the singing arc could be considered as the oldest memristor.

  11. Global Delivery Models

    DEFF Research Database (Denmark)

    Manning, Stephan; Møller Larsen, Marcus; Bharati, Pratyush

    We investigate antecedents and contingencies of location configurations supporting global delivery models (GDMs) in global outsourcing. GDMs are a new form of IT-enabled client-specific investment promoting services provision integration with clients by exploiting client proximity and time......-zone spread allowing for 24/7 service delivery and access to resources. Based on comprehensive data we show that providers are likely to establish GDM configurations when clients value access to globally distributed talent pools and speed of service delivery, and in particular when services are highly...... commoditized. Findings imply that coordination across time zones increasingly affects international operations in business-to-business and born-global industries....

  12. Laser-induced incandescence (LII) diagnostic for in situ monitoring of nanoparticle synthesis in a high-pressure arc discharge

    Science.gov (United States)

    Yatom, Shurik; Vekselman, Vladislav; Mitrani, James; Stratton, Brentley; Raitses, Yevgeny; LaboratoryPlasma Nanosynthesis Team

    2016-10-01

    A DC arc discharge is commonly used for synthesis of carbon nanoparticles, including buckyballs, carbon nanotubes, and graphene flakes. In this work we show the first results of nanoparticles monitored during the arc discharge. The graphite electrode is vaporized by high current (60 A) in a buffer Helium gas leading to nanoparticle synthesis in a low temperature plasma. The arc was shown to oscillate, which can possibly influence the nano-synthesis. To visualize the nanoparticles in-situ we employ the LII technique. The nanoparticles with radii >50 nm, emerging from the arc area are heated with a short laser pulse and incandesce. The resulting radiation is captured with an ICCD camera, showing the location of the generated nanoparticles. The images of incandescence are studied together with temporally synchronized fast-framing imaging of C2 emission, to connect the dynamics of arc instabilities, C2 molecules concentration and nanoparticles. The time-resolved incandescence signal is analyzed with combination of ex-situ measurements of the synthesized nanoparticles and LII modeling, to provide the size distribution of produced nanoparticles. This work was supported by US Department of Energy, Office of Science, Basic Energy Sciences, Materials Sciences and Engineering Division.

  13. Next generation high productivity submerged arc welding

    OpenAIRE

    LANGENOJA, MARKUS; Öhrvall Karlsson, Vincent

    2012-01-01

    The task of designing concepts for the next generation of submerged arc welding heads was given by ESAB. ESAB is a global company manufacturing welding equipment for a wide span of industries and uses. In October 2011, ESAB introduced a new technology called Integrated Cold Electrode™, abbreviated and trademarked as ICE™. ICE™ is a technique which utilizes three electrodes in a highly productive and stable process. The current state of the ICE™ technique focuses on welding thick plates with c...

  14. PSYCHOSOMATIC "ARC" IN THE PSYCHOTHERAPEUTIC PRACTICE

    OpenAIRE

    Ivanka Boncheva

    2012-01-01

    The psychoneuroimmunology, the new brain science and the endocrinology today show a lot of results, with which symptoms are better to understand. The psychotherapeutic practice shows the ways to influence them by encoding the levels of bounding between the physical symptom and the psychological condition. The aim of the study was to show the encoding of the psychosomatic arc within a real psychotherapeutic contact. 59 psychotherapeutic cases are followed. 33 of them were with somatoform disor...

  15. Volumetric modulated arc therapy for carotid sparing in the management of early glottic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Suk; Lee, Sol Min; Kim, Gwi Eon [Dept. of Radiation Oncology, Jeju National University Hospital, Jeju National University School of Medicine, Jeju (Korea, Republic of); Lee, Jae Gi; Park, Jong In; Sung, Won Mo [Program in Biomedical Radiation Sciences, Dept. of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of)

    2016-03-15

    Radiotherapy of the neck is known to cause carotid artery stenosis. We compared the carotid artery dose received between volumetric modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (IMRT) plans in patients with early glottic cancer. Twenty-one early glottic cancer patients who previously underwent definitive radiotherapy were selected for this study. For each patient, double arc VMAT, 8-field IMRT, 3-dimensional conformal radiotherapy (3DCRT), and lateral parallel-opposed photon field radiotherapy (LPRT) plans were created. The 3DCRT plan was generated using lateral parallel-opposed photon fields plus an anterior photon field. VMAT and IMRT treatment plan optimization was performed under standardized conditions to obtain adequate target volume coverage and spare the carotid artery. Dose-volume specifications for the VMAT, IMRT, 3DCRT, and LPRT plans were calculated with radiotherapy planning system. Monitor units (MUs) and delivery time were measured to evaluate treatment efficiency. Target volume coverage and homogeneity results were comparable between VMAT and IMRT; however, VMAT was superior to IMRT for carotid artery dose sparing. The mean dose to the carotid arteries in double arc VMAT was reduced by 6.8% compared to fixed-field IMRT (p < 0.001). The MUs for VMAT and IMRT were not significantly different (p = 0.089). VMAT allowed an approximately two-fold reduction in treatment delivery time in comparison to IMRT (3 to 5 minutes vs. 5 to 10 minutes). VMAT resulted in a lower carotid artery dose compared to conventional fixed-field IMRT, and maintained good target coverage in patients with early glottic cancer.

  16. Radiation Therapy for Early Stage Lung Cancer

    OpenAIRE

    Parashar, Bhupesh; Arora, Shruthi; Wernicke, A. Gabriella

    2013-01-01

    Radiation therapy for early stage lung cancer is a promising modality. It has been traditionally used in patients not considered candidates for standard surgical resection. However, its role has been changing rapidly since the introduction of new and advanced technology, especially in tumor tracking, image guidance, and radiation delivery. Stereotactic radiation therapy is one such advancement that has shown excellent local control rates and promising survival in early stage lung cancer. In a...

  17. Arc-Induced Long Period Fiber Gratings

    Directory of Open Access Journals (Sweden)

    Gaspar Rego

    2016-01-01

    Full Text Available Long period fiber gratings produced by the electric arc technique have found an increasing interest by the scientific community due to their ease to fabricate, virtually enabling the inscription in any kind of fiber, low cost, and flexibility. In 2005 we have presented the first review on this subject. Since then, important achievements have been reached such as the identification of the mechanisms responsible for gratings formation, the type of symmetry, the conditions to increase fabrication reproducibility, and their inscription in the turning points with grating periods below 200 μm. Several interesting applications in the sensing area, including those sensors working in reflection, have been demonstrated and others are expected, namely, related to the monitoring of extreme temperatures, cryogenic and high temperatures, and high sensitivity refractometric sensors resulting from combining arc-induced gratings in the turning points and the deposition of thin films in the transition region. Therefore, due to its pertinence, in this paper we review the main achievements obtained concerning arc-induced long period fiber gratings, with special focus on the past ten years.

  18. Spiraling Fermi arcs in Weyl materials

    Science.gov (United States)

    Li, Songci; Andreev, Anton

    In Weyl materials the valence and conduction electron bands touch at an even number of isolated points in the Brillouin zone. In the vicinity of these points the electron dispersion is linear and may be described by the massless Dirac equation. This results in nontrivial topology of Berry connection curvature. One of its consequences is the existence of peculiar surface electron states whose Fermi surfaces form arcs connecting projections of the Weyl points onto the surface plane. Band bending near the boundary of the crystal also produces surface states. We show that in Weyl materials band bending near the crystal surface gives rise to spiral structure of energy surfaces of arc states. The corresponding Fermi surface has the shape of a spiral that winds about the projection of the Weyl point onto the surface plane. The direction of the winding is determined by the helicity of the Weyl point and the sign of the band bending potential. For close valleys arc state morphology may be understood in terms of avoided crossing of oppositely winding spirals. This work is supported by the U.S. Department of Energy Office of Science, Basic Energy Sciences under Award Number DE-FG02-07ER46452.

  19. GlidArc-assisted processing of biogas

    Energy Technology Data Exchange (ETDEWEB)

    Czernichowski, A.; Wesolowska, K. (ECP, La Ferte St Aubin (France)), Email: echph@wanadoo.fr

    2009-07-01

    Power generation or chemical applications of biogas can be difficult when CH{sub 4} content is too low and / or in the presence of sulphur compounds. We therefore propose two reformers based on electric discharges (GlidArc) that strike directly either in a poor biogas or in waste CO{sub 2} + H{sub 2}S mixture generated during biogas cleaning. Direct application of GlidArc discharges to the poor biogas enhances its flammability through a partial conversion of CH{sub 4} + CO{sub 2} into hydrogen and carbon monoxide (synthesis gas). Any level of sulphur (and other impurities) is accepted. Roughly 40 % of injected electric power is transferred into upgraded biogas as its additional chemical enthalpy. A few percent of resultant H{sub 2} and CO inside the biogas makes it more flammable, and therefore better to fuel an engine or gas turbine. As a result of biogas purification via amines-washing technologies, one gets concentrated pollutants in CO{sub 2} matrix. Instead of classical neutralisation, we propose H{sub 2}Svalorisation through the SulfArc process converting all H{sub 2}S into additional amounts of synthesis gas, while neutral elemental sulphur is removed from the system. Generated syngas can be injected into the main biogas flow to enhance its flammability. (orig.)

  20. Longitudinal development of a substorm brightening arc

    Directory of Open Access Journals (Sweden)

    K. Shiokawa

    2009-05-01

    Full Text Available We present simultaneous THEMIS-ground observations of longitudinal (eastward extension of a substorm initial-brightening arc at Gillam (magnetic latitude: 65.6° at 08:13 UT on 10 January 2008. The speed of the eastward arc extension was ~2.7 km/s. The extension took place very close to the footprints of the longitudinally separated THEMIS E and D satellites at ~12 RE. The THEMIS satellites observed field dipolarization, weak earthward flow, and pressure increase, which propagated eastward from E to D at a speed of ~50 km/s. The THEMIS A satellite, located at 1.6 RE earthward of THEMIS E, observed fluctuating magnetic field during and after the dipolarization. The THEMIS E/D observations suggest that the longitudinal extension of the brightening arc at substorm onset is caused by earthward flow braking processes which produce field dipolarization and pressure increase propagating in longitude in the near-earth plasma sheet.

  1. Arc melter demonstration baseline test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process.

  2. Radiobiological risk estimates of adverse events and secondary cancer for proton and photon radiation therapy of pediatric medulloblastoma

    DEFF Research Database (Denmark)

    Brodin, N Patrik; Munck af Rosenschöld, Per Martin; Aznar, Marianne C;

    2011-01-01

    The aim of this model study was to estimate and compare the risk of radiation-induced adverse late effects in pediatric patients with medulloblastoma (MB) treated with either three-dimensional conformal radiotherapy (3D CRT), inversely-optimized arc therapy (RapidArc(®) (RA)) or spot-scanned inte...

  3. 4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung.

    Science.gov (United States)

    Chin, E; Loewen, S K; Nichol, A; Otto, K

    2013-02-21

    Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting treatment plans synchronize the delivery of each beam aperture to a specific phase of target motion. Stereotactic body radiation therapy treatment plans for 4D VMAT, gated VMAT, and 3D VMAT were generated on three patients with non-small cell lung cancer. Tumour motion ranged from 1.4-3.4 cm. The dose and fractionation scheme was 48 Gy in four fractions. A B-spline transformation model registered the 4D CT images. 4D dose volume histograms (4D DVH) were calculated from total dose accumulated at the maximum exhalation. For the majority of OARs, gated VMAT achieved the most radiation sparing but treatment times were 77-148% longer than 3D VMAT. 4D VMAT plan qualities were comparable to gated VMAT, but treatment times were only 11-25% longer than 3D VMAT. 4D VMAT's improvement of healthy tissue sparing can allow for further dose escalation. Future study could potentially adapt 4D VMAT to irregular patient breathing patterns.

  4. SU-E-T-64: A Programmable Moving Insert for the ArcCHECK Phantom for Dose Verification of Respiratory-Gated VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Gaede, S; Jordan, K [London Regional Cancer Program, London, ON (United Kingdom); Western University, London, ON (United Kingdom); Young, H [University of Waterloo, Waterloo, ON (Canada); Mulligan, M [London Regional Cancer Program, London, ON (United Kingdom)

    2015-06-15

    Purpose: To present a customized programmable moving insert for the ArcCHECK™ phantom that can, in a single delivery, check both entrance dosimetry, while simultaneously verifying the delivery of respiratory-gated VMAT. Methods: The cylindrical motion phantom uses a computer-controlled stepping motor to move an insert inside a stationery sleeve. Insert motion is programmable and can include rotational motion in addition to linear motion along the axis of the cylinder. The sleeve fits securely in the bore of the ArcCHECK™. Interchangeable inserts, including an A1SL chamber, optically-stimulated luminescence dosimeters, radiochromic film, or 3D gels, allow this combination to be used for commissioning, routine quality assurance, and patient-specific dosimetric verification of respiratory-gated VMAT. Before clinical implementation, the effect of a moving insert on the ArcCHECK™ measurements was considered. First, the measured dose to the ArcCHECK™ containing multiple inserts in the static position was compared to the calculated dose during multiple VMAT treatment deliveries. Then, dose was measured under both sinusoidal and real-patient motion conditions to determine any effect of the moving inserts on the ArcCHECK™ measurements. Finally, dose was measured during gated VMAT delivery to the same inserts under the same motion conditions to examine any effect of various beam “on-and-off” and dose rate ramp “up-and-down”. Multiple comparisons between measured and calculated dose to different inserts were also considered. Results: The pass rate for the static delivery exceeded 98% for all measurements (3%/3mm), suggesting a valid setup for entrance dosimetry. The pass rate was not altered for any measurement delivered under motion conditions. A similar Result was observed under gated VMAT conditions, including agreement of measured and calculated dose to the various inserts. Conclusion: Incorporating a programmable moving insert within the Arc

  5. SU-C-BRB-05: Investigation of Conformal Arc Therapy Utilizing Newly Designed Cobalt 60 Machine

    Energy Technology Data Exchange (ETDEWEB)

    Eldib, A [Fox Chase Cancer Center, Philadelphia, PA (United States); Department of Physics, AlAzhar University, Cairo (Egypt); Chibani, O; Jin, L; Li, J; Veltchev, I; Price, R; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal)

    2015-06-15

    Purpose: A new modernized design for cobalt 60 (Co-60) machines is being developed with a ring type gantry. In this study we investigate the beneficial outcome of the new design for conformal arc therapy for various clinical sites. The new modality was evaluated based on isodose distributions and dose volume histograms as compared to 6MV photon beams from conventional linear accelerators. Methods: Computed tomographic images of seven different SBRT patients were selected from our patient database. All of these cases were previously planned on the Eclipse treatment planning system. New plans for these patients were generated with a modified conformal arc technique using both 6MV and Co-60 beams. The conformal arc was created by the delivery of treatment fields conformal to the target cross-section at every 5 or 10 degrees. The field shape was modified or turned off when it initially passed through a critical structure. Monte Carlo codes, MCBEAM and MCPLAN, were used for the machine head simulation and phantom/patient dose calculation, respectively. In the new Co-60 machine design, the source-to-isocenter distance was 60cm and the treatment head included the Co-60 source, primary collimator, jaws and MLC. Results: For all cases investigated, conformal arc plans utilizing Co-60 beams achieved similar conformity (mean conformity index=1.19) comparing to 6MV photon beams. Isodose distributions were tailored similarly around the PTV; both Co-60 and 6MV plans met our clinical acceptance criteria for the target coverage, and the maximum and minimum target doses. The DVH for the Co-60 plans showed slightly lower doses to the critical structures although the differences were small in most cases. Conclusion: There were no significant dosimetric differences between 6MV and Co-60 plans. Our results confirmed that this new Co-60 design could be a cost-effective machine for advanced radiotherapy due to its low cost, low maintenance and high up time.

  6. Arc Facilities Manager (ArcFM)-ARC/INFO的功能强大的公用事业应用程序%Arc Facilities Manager(ArcFM)-A Powerful ARC/INFO-Based Application for

    Institute of Scientific and Technical Information of China (English)

    陆朝晖; 赵小红; 朱晓岷

    2000-01-01

    市场经济条件下公用事业面临新的挑战,地理信息系统(GIS)有助于公用事业有效管理公用设施,从而在竞争中获得优势.围绕ESRI公司的ArcFM软件,从它的结构、性能和功能等几方面,阐述了公用事业管理系统的一种解决方案.

  7. Delivery by Cesarean Section

    Science.gov (United States)

    ... Español Text Size Email Print Share Delivery by Cesarean Section Page Content Article Body More than one mother in three gives birth by Cesarean section in the United States (it is also called ...

  8. Transdermal delivery of proteins.

    Science.gov (United States)

    Kalluri, Haripriya; Banga, Ajay K

    2011-03-01

    Transdermal delivery of peptides and proteins avoids the disadvantages associated with the invasive parenteral route of administration and other alternative routes such as the pulmonary and nasal routes. Since proteins have a large size and are hydrophilic in nature, they cannot permeate passively across the skin due to the stratum corneum which allows the transport of only small lipophilic drug molecules. Enhancement techniques such as chemical enhancers, iontophoresis, microneedles, electroporation, sonophoresis, thermal ablation, laser ablation, radiofrequency ablation and noninvasive jet injectors aid in the delivery of proteins by overcoming the skin barrier in different ways. In this review, these enhancement techniques that can enable the transdermal delivery of proteins are discussed, including a discussion of mechanisms, sterility requirements, and commercial development of products. Combination of enhancement techniques may result in a synergistic effect allowing increased protein delivery and these are also discussed.

  9. Arc Jet Facility Test Condition Predictions Using the ADSI Code

    Science.gov (United States)

    Palmer, Grant; Prabhu, Dinesh; Terrazas-Salinas, Imelda

    2015-01-01

    The Aerothermal Design Space Interpolation (ADSI) tool is used to interpolate databases of previously computed computational fluid dynamic solutions for test articles in a NASA Ames arc jet facility. The arc jet databases are generated using an Navier-Stokes flow solver using previously determined best practices. The arc jet mass flow rates and arc currents used to discretize the database are chosen to span the operating conditions possible in the arc jet, and are