WorldWideScience

Sample records for aqueous solution properties

  1. Thermodynamic properties of potassium chloride aqueous solutions

    Science.gov (United States)

    Zezin, Denis; Driesner, Thomas

    2017-04-01

    Potassium chloride is a ubiquitous salt in natural fluids, being the second most abundant dissolved salt in many geological aqueous solutions after sodium chloride. It is a simple solute and strong electrolyte easily dissociating in water, however the thermodynamic properties of KCl aqueous solutions were never correlated with sufficient accuracy for a wide range of physicochemical conditions. In this communication we propose a set of parameters for a Pitzer-type model which allows calculation of all necessary thermodynamic properties of KCl solution, namely excess Gibbs free energy and derived activity coefficient, apparent molar enthalpy, heat capacity and volume, as well as osmotic coefficient and activity of water in solutions. The system KCl-water is one of the best studied aqueous systems containing electrolytes. Although extensive experimental data were collected for thermodynamic properties of these solutions over the years, the accurate volumetric data became available only recently, thus making possible a complete thermodynamic formulation including a pressure dependence of excess Gibbs free energy and derived properties of the KCl-water liquids. Our proposed model is intended for calculation of major thermodynamic properties of KCl aqueous solutions at temperatures ranging from freezing point of a solution to 623 K, pressures ranging from saturated water vapor up to 150 MPa, and concentrations up to the salt saturation. This parameterized model will be further implemented in geochemical software packages and can facilitate the calculation of aqueous equilibrium for reactive transport codes.

  2. Thermodynamic properties of aqueous solutions with citrate ions. Compressibility studies in aqueous solutions of citric acid

    International Nuclear Information System (INIS)

    Apelblat, Alexander; Korin, Eli; Manzurola, Emanuel

    2013-01-01

    Highlights: • Over a wide range of concentrations and temperatures sound velocities were measured in aqueous solutions of citric acid. • Compressibility properties of citric acid solutions are thermodynamically characterized. • Changes in the structure of water when citric acid is dissolved are discussed. -- Abstract: Sound velocities in aqueous solutions of citric acid were measured from 15 °C to 50 °C in 5 °C intervals, within the 0.1 mol · kg −1 to 5.0 mol · kg −1 concentration range. These sound velocities served to evaluate the isentropic and isothermal compressibilities, the apparent molar compressibilities, the isochoric thermal pressure coefficients, changes of the cubic expansion coefficients with pressure at constant temperature, the changes of heat capacities with volume and hydration numbers of citric acid in aqueous solutions

  3. OPTICAL PROPERTIES OF CARBAMIDE AQUEOUS SOLUTIONS

    Directory of Open Access Journals (Sweden)

    E. V. Avramenko

    2016-03-01

    Full Text Available Subject of Research. The paper presents the results of measurements of refractometric properties (refractive index n, its temperature factor dn/dt and the ultraviolet spectral absorption in carbonic acid diamide aqueous solutions (carbamide depending on solid residue mass fraction md = 0-50 % and on temperaturet = 10-70 °C.Method of Research. Laboratory methods ofliquid-phase medium refractometry and ultraviolet spectrophotometry were applied for the research. We carried out computational modeling of electronic states spectrum for the carbonic acid diamide molecule and theoretical calculation of the fundamental electronic absorption of the molecule in the ultraviolet wavelenght region.Main Results. We have established that the solution concentration md has a nonlinear character and may be represented by the quadratic polynomial with the error Δn= ± 0,0005. We have shown the refractive indexdependence on temperature n(t changes in linear fashion att = 10-70 °C.At that, the inclination of lines n(t increases at the increase of md; so, the temperature factor dn/dt may be approximated by the quadratic polynomial. Transmission spectra of solutions in the spectral region λ= 225-760 nm have no special features except for the sharp edge in the short-wavelength region; the fundamental electronic absorptionis responsible for it. We have established that dispersion dependences of the refraction index n(λ;md in aqueous solutions of carbamide at λ= 360-760 nm and at md = 0-50 % may be calculated with the satisfactory error without additional adjustable parameters from the ultraviolet absorption data in terms of the one-dimentional oscillator Lorentz model.PracticalRelevance. Representedmeasurements of carbonic acid diamide aqueous solutions optical properties may be applied for the adjustment and calibration of commercial refractometers at processing lines of the AdBlue reagent manufacture for the selective catalytic reduction (SCR of motor transport

  4. Method for Non-Invasive Determination of Chemical Properties of Aqueous Solutions

    Science.gov (United States)

    Todd, Paul W. (Inventor); Jones, Alan (Inventor); Thomas, Nathan A. (Inventor)

    2016-01-01

    A method for non-invasively determining a chemical property of an aqueous solution is provided. The method provides the steps of providing a colored solute having a light absorbance spectrum and transmitting light through the colored solute at two different wavelengths. The method further provides the steps of measuring light absorbance of the colored solute at the two different transmitted light wavelengths, and comparing the light absorbance of the colored solute at the two different wavelengths to determine a chemical property of an aqueous solution.

  5. Thermophysical property characterization of aqueous amino acid salt solution containing serine

    International Nuclear Information System (INIS)

    Navarro, Shanille S.; Leron, Rhoda B.; Soriano, Allan N.; Li, Meng-Hui

    2014-01-01

    Highlights: • Thermophysical properties of aqueous potassium and sodium salt solutions of serine were studied. • Density, viscosity, refractive index and electrolytic conductivity of the solution were measured. • The concentrations of amino acid salt ranges from x 1 = 0.009 to 0.07. • The temperature range studied was (298.15 to 343.15) K. • The measured data were represented satisfactorily by using the applied correlations. - Abstract: Thermophysical property characterization of aqueous potassium and sodium salt solutions containing serine was conducted in this study; specifically the system’s density, refractive index, electrical conductivity, and viscosity. Measurements were obtained over a temperature range of (298.15 to 343.15) K and at normal atmospheric pressure. Composition range from x 1 = 0.009 to 0.07 for aqueous potassium and sodium salt solutions containing serine was used. The sensitivity of the system’s thermophysical properties on temperature and composition variation were discussed and correlated based on the equations proposed for room temperature ionic liquids. The density, viscosity, and refractive index measurements of the aqueous systems were found to decrease as the temperature increases at fixed concentration and the values increase as the salt concentration increases (water composition decreases) at fixed temperature. Whereas, a different trend was observed for the electrical conductivity data; at fixed concentration, the conductivity values increase as the temperature increases and at fixed temperature, its value generally increases as the salt concentration increases but only to a certain level (specific concentration) wherein the conductivity of the solution starts to decrease when the concentration of the salt is further increased. Calculation results show that the applied models were satisfactory in representing the measured properties in the aqueous amino acid salt solution containing serine

  6. Volumetric and calorimetric properties of aqueous ionene solutions.

    Science.gov (United States)

    Lukšič, Miha; Hribar-Lee, Barbara

    2017-02-01

    The volumetric (partial and apparent molar volumes) and calorimetric properties (apparent heat capacities) of aqueous cationic polyelectrolyte solutions - ionenes - were studied using the oscillating tube densitometer and differential scanning calorimeter. The polyion's charge density and the counterion properties were considered as variables. The special attention was put to evaluate the contribution of electrostatic and hydrophobic effects to the properties studied. The contribution of the CH 2 group of the polyion's backbone to molar volumes and heat capacities was estimated. Synergistic effect between polyion and counterions was found.

  7. Examination of rheological properties of aqueous solutions of sodium caseinate

    OpenAIRE

    Jolanta Gawałek; Piotr Wesołowski

    2012-01-01

    Application of sodium caseinate as a functional additive in manufacturing processes requires production of its concentrated aqueous solutions which, in industrial conditions, presents a number of difficulties. In order to develop an effective and optimal industrial process of mixing – manufacturing a concentrated solution of sodium caseinate, it is essential to know rheological properties in a definite range of concentrations changing in the course of the dissolving process. The materia...

  8. Electronic Properties of Functional Biomolecules at Metal/Aqueous Solution Interfaces

    DEFF Research Database (Denmark)

    Zhang, Jingdong; Chi, Qijin; Kuznetsov, A.M.

    2002-01-01

    in electronic properties and stochastic single-molecule features and can be probed by new methods which approach the single-molecule level. Olle of these is in situ scanning tunneling microscopy (STM) in which single-molecule electronic properties directly in aqueous solution are probed. In situ STM combined...... with physical electrochemistry, single-crystal electrodes, and spectroscopic methods is now a new dimension in interfacial bioelectrochemistry. We overview first same approaches to spectroscopic single-molecule imaging, including fluorescence spectroscopy, chemical reaction dynamics, atomic force microscopy...

  9. Molecular dynamics simulations of the dielectric properties of fructose aqueous solutions

    International Nuclear Information System (INIS)

    Sonoda, Milton T; Dolores Elola, M; Skaf, Munir S

    2016-01-01

    The static dielectric permittivity and dielectric relaxation properties of fructose aqueous solutions of different concentrations ranging from 1.0 to 4.0 mol l −1 are investigated by means of molecular dynamics simulations. The contributions from intra- and interspecies molecular correlations were computed individually for both the static and frequency-dependent dielectric properties, and the results were compared with the available experimental data. Simulation results in the time- and frequency-domains were analyzed and indicate that the presence of fructose has little effect on the position of the fast, high-frequency (>500 cm −1 ) components of the dielectric response spectrum. The low-frequency (<0.1 cm −1 ) components, however, are markedly influenced by sugar concentration. Our analysis indicates that fructose–fructose and fructose–water interactions strongly affect the rotational-diffusion regime of molecular motions in the solutions. Increasing fructose concentration not only enhances sugar–sugar and sugar-water low frequency contributions to the dielectric loss spectrum but also slows down the reorientational dynamics of water molecules. These results are consistent with previous computer simulations carried out for other disaccharide aqueous solutions. (paper)

  10. Diffusion of aqueous solutions of ionic, zwitterionic, and polar solutes

    Science.gov (United States)

    Teng, Xiaojing; Huang, Qi; Dharmawardhana, Chamila Chathuranga; Ichiye, Toshiko

    2018-06-01

    The properties of aqueous solutions of ionic, zwitterionic, and polar solutes are of interest to many fields. For instance, one of the many anomalous properties of aqueous solutions is the behavior of water diffusion in different monovalent salt solutions. In addition, solutes can affect the stabilities of macromolecules such as proteins in aqueous solution. Here, the diffusivities of aqueous solutions of sodium chloride, potassium chloride, tri-methylamine oxide (TMAO), urea, and TMAO-urea are examined in molecular dynamics simulations. The decrease in the diffusivity of water with the concentration of simple ions and urea can be described by a simple model in which the water molecules hydrogen bonded to the solutes are considered to diffuse at the same rate as the solutes, while the remainder of the water molecules are considered to be bulk and diffuse at almost the same rate as pure water. On the other hand, the decrease in the diffusivity of water with the concentration of TMAO is apparently affected by a decrease in the diffusion rate of the bulk water molecules in addition to the decrease due to the water molecules hydrogen bonded to TMAO. In other words, TMAO enhances the viscosity of water, while urea barely affects it. Overall, this separation of water molecules into those that are hydrogen bonded to solute and those that are bulk can provide a useful means of understanding the short- and long-range effects of solutes on water.

  11. Effect of temperature on the behavior of surface properties of alcohols in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Carmen M. [Facultad de Ciencias, Universidad Nacional de Colombia, Bogota (Colombia)], E-mail: cmromeroi@unal.edu.co; Jimenez, Eulogio [Facultade de Ciencias, Universidade da Coruna (Spain); Suarez, Felipe [Facultad de Ciencias, Universidad Nacional de Colombia, Bogota (Colombia)

    2009-04-15

    The influence of temperature on the behavior of surface properties of aqueous solutions has often been used to obtain information about solute structural effects on water. In this work, we present experimental results for surface tension of aqueous solutions of n-pentanol, n-hexanol, n-heptanol, and n-octanol at T = (283.15, 288.15, 293.15, 298.15, 303.15, and 308.15) K at several concentrations. The results were used to evaluate the limiting experimental slopes of surface tension with respect to mole fraction and the hydrophobicity constant of the Connors model at each temperature. The thermodynamic behavior of aqueous alcohol solutions is discussed in terms of the effect of the hydrocarbon chain on water structure. The temperature dependence of the limiting slopes of surface tension with respect to mole fraction, as well as the hydrophobicity constant derived from surface measurements, is interpreted in terms of alcohol hydration.

  12. Effect of temperature on the behavior of surface properties of alcohols in aqueous solution

    International Nuclear Information System (INIS)

    Romero, Carmen M.; Jimenez, Eulogio; Suarez, Felipe

    2009-01-01

    The influence of temperature on the behavior of surface properties of aqueous solutions has often been used to obtain information about solute structural effects on water. In this work, we present experimental results for surface tension of aqueous solutions of n-pentanol, n-hexanol, n-heptanol, and n-octanol at T = (283.15, 288.15, 293.15, 298.15, 303.15, and 308.15) K at several concentrations. The results were used to evaluate the limiting experimental slopes of surface tension with respect to mole fraction and the hydrophobicity constant of the Connors model at each temperature. The thermodynamic behavior of aqueous alcohol solutions is discussed in terms of the effect of the hydrocarbon chain on water structure. The temperature dependence of the limiting slopes of surface tension with respect to mole fraction, as well as the hydrophobicity constant derived from surface measurements, is interpreted in terms of alcohol hydration

  13. Effect of alkyl chain length and temperature on the thermodynamic properties of ionic liquids 1-alkyl-3-methylimidazolium bromide in aqueous and non-aqueous solutions at different temperatures

    International Nuclear Information System (INIS)

    Sadeghi, Rahmat; Shekaari, Hemayat; Hosseini, Rahim

    2009-01-01

    The alkyl chain length of 1-alkyl-3-methylimidazolium bromide ([Rmim][Br], R = propyl (C 3 ), hexyl (C 6 ), heptyl (C 7 ), and octyl (C 8 )) was varied to prepare a series of room-temperature ionic liquids (RTILs), and experimental measurements of density and speed of sound at different temperatures ranging from (288.15 to 308.15) K for their aqueous and methanolic solutions in the dilute concentration region (0.01 to 0.30) mol . kg -1 were taken. The values of the compressibilities, expansivity and apparent molar properties for [C n mim][Br] in aqueous and methanolic solutions were determined at the investigated temperatures. The obtained apparent molar volumes and apparent molar isentropic compressibilities were fitted to the Redlich-Mayer and the Pitzer's equations from which the corresponding infinite dilution molar properties were obtained. The values of the infinite dilution molar properties were used to obtain some information about solute-solvent and solute-solute interactions. The thermodynamic properties of investigated ionic liquids in aqueous solutions have been compared with those in methanolic solutions. Also, the comparison between thermodynamic properties of investigated solutions and those of electrolyte solutions, polymer solutions, cationic surfactant solutions and tetraalkylammonium salt solutions have been made

  14. Effect of alkyl chain length and temperature on the thermodynamic properties of ionic liquids 1-alkyl-3-methylimidazolium bromide in aqueous and non-aqueous solutions at different temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, Rahmat [Department of Chemistry, University of Kurdistan, Sanandaj (Iran, Islamic Republic of)], E-mail: rahsadeghi@yahoo.com; Shekaari, Hemayat [Department of Chemistry, Faculty of Science, University of Mohaghegh Ardabili, Ardabil (Iran, Islamic Republic of); Hosseini, Rahim [Department of Chemistry, University of Kurdistan, Sanandaj (Iran, Islamic Republic of)

    2009-02-15

    The alkyl chain length of 1-alkyl-3-methylimidazolium bromide ([Rmim][Br], R = propyl (C{sub 3}), hexyl (C{sub 6}), heptyl (C{sub 7}), and octyl (C{sub 8})) was varied to prepare a series of room-temperature ionic liquids (RTILs), and experimental measurements of density and speed of sound at different temperatures ranging from (288.15 to 308.15) K for their aqueous and methanolic solutions in the dilute concentration region (0.01 to 0.30) mol . kg{sup -1} were taken. The values of the compressibilities, expansivity and apparent molar properties for [C{sub n}mim][Br] in aqueous and methanolic solutions were determined at the investigated temperatures. The obtained apparent molar volumes and apparent molar isentropic compressibilities were fitted to the Redlich-Mayer and the Pitzer's equations from which the corresponding infinite dilution molar properties were obtained. The values of the infinite dilution molar properties were used to obtain some information about solute-solvent and solute-solute interactions. The thermodynamic properties of investigated ionic liquids in aqueous solutions have been compared with those in methanolic solutions. Also, the comparison between thermodynamic properties of investigated solutions and those of electrolyte solutions, polymer solutions, cationic surfactant solutions and tetraalkylammonium salt solutions have been made.

  15. Volumetric properties of itaconic acid aqueous solutions

    International Nuclear Information System (INIS)

    Nisenbaum, Alexander; Apelblat, Alexander; Manzurola, Emanuel

    2012-01-01

    Highlights: ► Densities of itaconic acid aqueous solutions in a wide range of concentrations and temperatures. ► The apparent molar volumes and the cubic expansion coefficients. ► The derivatives of isobaric heat capacities with respect to pressure. ► Changes in the structure of water when itaconic acid is dissolved. - Abstract: Densities of itaconic acid aqueous solutions were measured at 5 K intervals from T = (278.15 to 343.15) K. From the determined densities, the apparent molar volumes, the cubic expansion coefficients and the second derivatives of volume with respect to temperature which are interrelated with the derivatives of isobaric heat capacities with respect to pressure were evaluated. These derivatives were qualitatively correlated with the changes in the structure of water when itaconic acid is dissolved in it.

  16. Thermophysical Properties of Aqueous Solutions Used as Secondary Working Fluids

    OpenAIRE

    Melinder, Åke

    2007-01-01

    Secondary working fluids (secondary refrigerants, heat transfer fluids, antifreezes, brines) have long been used in various indirect re-frigeration and heat pump systems. Aqueous solutions (water solu-tions) have long been used as single phase (liquid only) secondary working fluids for cooling in supermarkets, ice rinks, heat recovery systems, heat pumps and other applications. However, aqueous solutions are increasingly used also for freezers in supermarkets and other applications in low tem...

  17. Environment-Friendly Post-Treatment of PEDOT-Tos Films by Aqueous Vitamin C Solutions for Tuning of Thermoelectric Properties

    Science.gov (United States)

    Khan, Ezaz Hasan; Thota, Sammaiah; Wang, Yiwen; Li, Lian; Wilusz, Eugene; Osgood, Richard; Kumar, Jayant

    2018-04-01

    Aqueous vitamin C solution has been used as an environment-friendly reducing agent for tuning the thermoelectric properties of p-toluenesulfonate-doped poly(3,4-ethylenedioxythiophene) (PEDOT-Tos) films. The de-doping of the PEDOT-Tos films by aqueous vitamin C solutions led to a decrease in the electrical conductivity of the films. The measured ultraviolet-visible-near-infrared and x-ray photoelectron spectra clearly indicated the reduction in the oxidation level from 37 to 23% when the PEDOT-Tos films were treated with 5% (w/v) aqueous vitamin C solutions. An increase in the Seebeck coefficient was measured, resulting in an increase in the figure-of-merit (ZT). A 42% increase in ZT was determined for the 5% aqueous vitamin C solution-treated PEDOT-Tos films with respect to that of the untreated films.

  18. Formation and disappearance of superoxide radicals in aqueous solutions

    International Nuclear Information System (INIS)

    Allen, A.O.; Bielski, B.H.J.

    1980-01-01

    A literature review of superoxide radicals in aqueous solutions is presented covering the following: history; methods of formation of aqueous HO 2 /HO 2 - by radiolysis and photolysis, electrolysis, mixing nonaqueous solutions into water, chemical reactions, enzymatic generation of O 2 - , and photosensitization; and properties of HO 2 /O 2 - in aqueous solution, which cover spontaneous dismutation rates, pk and absorption spectra, catalyzed dismutation, thermodynamics and the so-called Haber-Weiss Reaction

  19. Thermodynamic properties of aqueous hydroxyurea solutions

    International Nuclear Information System (INIS)

    Kumar, Shekhar; Sinha, Pranay Kumar; Kamachi Mudali, U.; Natarajan, R.

    2011-01-01

    Hydroxyurea is a novel reductant for uranium-plutonium separation in PUREX process. Little information on its thermophysical properties is available in published literature. In this work, its contributions to aqueous density, apparent molal volume, vapour pressure and thermodynamic water activity values, derived from in-house experiments, are reported. (author)

  20. Luminescence properties of tetravalent uranium in aqueous solution

    International Nuclear Information System (INIS)

    Kirishima, A.; Kimura, T.; Nagaishi, R.; Tochiyama, O.

    2004-01-01

    The luminescence spectra of U 4+ in aqueous solutions were observed in the UV-VIS region at ambient and liquid nitrogen temperatures. The excitation spectrum indicates that the luminescence is arising from the deexcitation of a 5f electron at the 1 S 0 level and no other emissions of U 4+ in aqueous solutions were detected for other f-f transitions. All the luminescence peaks were assigned to the transitions from 1 S 0 to lower 5f levels. To estimate the luminescence lifetime, luminescence decay curves were measured using time-resolved laser-induced fluorescence spectroscopy. At room temperature, the decay curve indicated that the lifetime was shorter than 20 ns. On the other hand, the frozen sample of U 4+ in aqueous solution at liquid nitrogen temperature showed the same emission spectrum as at room temperature and its lifetime was 149 ns in H 2 O system and 198 ns in D 2 O system. The longer lifetime at liquid nitrogen temperature made it possible to measure the spectrum of U 4+ at the concentration as low as 10 -6 M. The difference in the anion species (ClO 4 - , Cl - , SO 4 2- ) affected the structure of the emission spectrum to some extent. (orig.)

  1. Thermal and volumetric properties of complex aqueous electrolyte solutions using the Pitzer formalism - The PhreeSCALE code

    Science.gov (United States)

    Lach, Adeline; Boulahya, Faïza; André, Laurent; Lassin, Arnault; Azaroual, Mohamed; Serin, Jean-Paul; Cézac, Pierre

    2016-07-01

    The thermal and volumetric properties of complex aqueous solutions are described according to the Pitzer equation, explicitly taking into account the speciation in the aqueous solutions. The thermal properties are the apparent relative molar enthalpy (Lϕ) and the apparent molar heat capacity (Cp,ϕ). The volumetric property is the apparent molar volume (Vϕ). Equations describing these properties are obtained from the temperature or pressure derivatives of the excess Gibbs energy and make it possible to calculate the dilution enthalpy (∆HD), the heat capacity (cp) and the density (ρ) of aqueous solutions up to high concentrations. Their implementation in PHREEQC V.3 (Parkhurst and Appelo, 2013) is described and has led to a new numerical tool, called PhreeSCALE. It was tested first, using a set of parameters (specific interaction parameters and standard properties) from the literature for two binary systems (Na2SO4-H2O and MgSO4-H2O), for the quaternary K-Na-Cl-SO4 system (heat capacity only) and for the Na-K-Ca-Mg-Cl-SO4-HCO3 system (density only). The results obtained with PhreeSCALE are in agreement with the literature data when the same standard solution heat capacity (Cp0) and volume (V0) values are used. For further applications of this improved computation tool, these standard solution properties were calculated independently, using the Helgeson-Kirkham-Flowers (HKF) equations. By using this kind of approach, most of the Pitzer interaction parameters coming from literature become obsolete since they are not coherent with the standard properties calculated according to the HKF formalism. Consequently a new set of interaction parameters must be determined. This approach was successfully applied to the Na2SO4-H2O and MgSO4-H2O binary systems, providing a new set of optimized interaction parameters, consistent with the standard solution properties derived from the HKF equations.

  2. Photochemical properties of Ysub(t) base in aqueous solution

    International Nuclear Information System (INIS)

    Paszyc, S.; Rafalska, M.

    1979-01-01

    Photoreactivity of Ysub(t) base (I) has been studied in aqueous solution (pH-6) saturated with oxygen. Two photoproducts (II,III), resulting from irradiation at lambda = 253.7 nm and lambda >= 290 nm were isolated and their structures determined. The quantum yield for Ysub(t) base disappearance (rho dis) is 0.002 (lambda = 313 nm). It was shown that dye- sensitised photo-oxidation of Ysub(t) base in aqueous solution occurs according to a Type I mechanism as well as with participation of singlet state oxygen. Quantum yields, fluorescence decay times and phosphorescence of Ysub(t) base have also been determined. (author)

  3. Formation of magnetite (Fe3O4)in aqueous media and properties of the interface magnetite/solution

    International Nuclear Information System (INIS)

    Regazzoni, A.E.

    1984-01-01

    The formation of Fe 3 O 4 particles in aqueous media and the properties of the Fe 3 O 4 /aqueous solution interface are studied. This system is of particular interest in nuclear reactor chemistry, since Fe 3 O 4 was identified as the main component of the corrosion products of nuclear power plants cooled with pressurized water, of the Atucha I and II, and Embalse type. Four methods for the synthesis of Fe 3 O 4 are described: a) controlled oxidation of Fe(OH) 2 in the presence of NaNO 3 at 25 deg C; b) controlled oxidation of Fe(OH) 2 in the presence of NaNO 3 and N 2 H 4 and at 100 deg C; c) alkalinization of a F 2+ and Fe 3+ solutions at 80 deg C; d) simultaneous oxidation and alkalinization of a Fe 2+ . The interfacial properties of Fe 3 O 4 particles suspended in aqueous solutions of indifferent electrolytes are described. These properties are essential for the activity transport associated with the corrosion products. Finally, the adsorption of H 3 BO 3 , Hsub(n)PO 4 sup(n-3) and n Co(II) in the Fe 3 O 4 /solution interface at 30 deg C. It is concluded that the adsorbed species are chemically bonded to surface metal ions. (M.E.L.) [es

  4. Dielectric properties of binary solutions a data handbook

    CERN Document Server

    Akhadov, Y Y

    1980-01-01

    Dielectric Properties of Binary Solutions focuses on the investigation of the dielectric properties of solutions, as well as the molecular interactions and mechanisms of molecular processes that occur in liquids. The book first discusses the fundamental formulas describing the dielectric properties of liquids and dielectric data for binary systems of non-aqueous solutions. Topics include permittivity and dielectric dispersion parameters of non-aqueous solutions of organic and inorganic compounds. The text also tackles dielectric data for binary systems of aqueous solutions, including permittiv

  5. Physico-chemical properties of aqueous drug solutions: From the basic thermodynamics to the advanced experimental and simulation results.

    Science.gov (United States)

    Bellich, Barbara; Gamini, Amelia; Brady, John W; Cesàro, Attilio

    2018-04-05

    The physical chemical properties of aqueous solutions of model compounds are illustrated in relation to hydration and solubility issues by using three perspectives: thermodynamic, spectroscopic and molecular dynamics simulations. The thermodynamic survey of the fundamental backgrounds of concentration dependence and experimental solubility results show some peculiar behavior of aqueous solutions with several types of similar solutes. Secondly, the use of a variety of experimental spectroscopic devices, operating under different experimental conditions of dimension and frequency, has produced a large amount of structural and dynamic data on aqueous solutions showing the richness of the information produced, depending on where and how the experiment is carried out. Finally, the use of molecular dynamics computational work is presented to highlight how the different types of solute functional groups and surface topologies organize adjacent water molecules differently. The highly valuable contribution of computer simulation studies in providing molecular explanations for experimental deductions, either of a thermodynamic or spectroscopic nature, is shown to have changed the current knowledge of many aqueous solution processes. While this paper is intended to provide a collective view on the latest literature results, still the presentation aims at a tutorial explanation of the potentials of the three methodologies in the field of aqueous solutions of pharmaceutical molecules. Copyright © 2018. Published by Elsevier B.V.

  6. LASERS, ACTIVE MEDIA: The aqueous-polyelectrolyte dye solution as an active laser medium

    Science.gov (United States)

    Akimov, A. I.; Saletskii, A. M.

    2000-11-01

    The spectral, luminescent, and lasing properties of aqueous solutions of a cationic dye rhodamine 6G with additions of anion polyelectrolytes — polyacrylic and polymethacrylic acids — are studied. It is found that the energy and spectral properties of lasing of these solutions depend on the ratio of concentrations of polyelectrolyte and molecules. It is also found that the lasing parameters of aqueous-polyelectrolyte dye solutions can be controlled by changing the structure of the molecular system. The variation in the structure of aqueous-polyelectrolyte dye solutions of rhodamine 6G resulted in an almost five-fold increase in the lasing efficiency compared to that in aqueous dye solutions.

  7. Aqueous solutions of ionic liquids: microscopic assembly

    NARCIS (Netherlands)

    Vicent-Luna, J.M.; Dubbeldam, D.; Gómez-Álvarez, P.; Calero, S.

    2016-01-01

    Aqueous solutions of ionic liquids are of special interest, due to the distinctive properties of ionic liquids, in particular, their amphiphilic character. A better understanding of the structure-property relationships of such systems is hence desirable. One of the crucial molecular-level

  8. Effect of sodium tetraborate (borax) on the thermal properties of frozen aqueous sugar and polyol solutions.

    Science.gov (United States)

    Izutsu, Ken-ichi; Rimando, Annie; Aoyagi, Nobuo; Kojima, Shigeo

    2003-06-01

    The effect of sodium tetraborate (Na(2)B(4)O(7), borax) on the thermal property of frozen aqueous sugar and polyol solutions was studied through thermal analysis. Addition of borax raised the thermal transition temperature (glass transition temperature of maximally freeze-concentrated solutes; T(g)') of frozen sucrose solutions depending on the borax/sucrose concentration ratios. Changes in the T(g)' of frozen mono- and disaccharide solutions suggested various forms of complexes, including those of a borate ion and two saccharide molecules. Borax exerted the maximum effect to raise the oligosaccharide and dextran T(g)'s at borax/saccharide molar ratios of approximately 1-2 (maltose and maltooligosaccharides), 2 (dextran 1060), 5 (dextran 4900), and 10 (dextran 10200). Further addition of borax lowered T(g)'s of the saccharide solutions. Borax also raised T(g) and T(g)' temperatures of frozen aqueous glycerol solutions. The decreased solute mobility in frozen solutions by the borate-polyol complexes suggested higher collapse temperature in the freeze-drying process and improved stability of biological systems in frozen solutions.

  9. Volumetric properties of l-alanine, and l-valine in aqueous sucrose solutions at T=(288.15 and 308.15) K

    International Nuclear Information System (INIS)

    Pal, Amalendu; Kumar, Suresh

    2005-01-01

    Densities of l-alanine, and l-valine have been measured at T=(288.15 and 308.15) K in aqueous sucrose solutions ranging from pure water to 25 mass% of sucrose. From these densities, apparent molar volumes (V φ ) and limiting partial molar volumes (V φ 0 ) of each amino acid in various aqueous sucrose solutions have been evaluated. These data were combined with the earlier reported V φ 0 values of l-alanine, and l-valine in aqueous sucrose solutions at T=298.15 K to calculate the (-bar V φ 0 /-bar T) P values. The partial molar properties of transfer (ΔV φ 0 ) from water to aqueous sucrose solutions at infinite dilution has been calculated. Transfer parameters have been interpreted in terms of solute-cosolute interactions on the basis of a cosphere overlap model. Pair and triplet interaction coefficients have also been calculated from transfer volume data

  10. Preliminary study on lithium-salt aqueous solution blanket

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Naruse, Yuji; Yamaoka, Mitsuaki; Ohara, Atsushi; Ono, Kiyoshi; Kobayashi, Shigetada.

    1992-06-01

    Aqueous solution blanket using lithium salts such as LiNO 3 and LiOH have been studied in the US-TIBER program and ITER conceptual design activity. In the JAERI/LANL collaboration program for the joint operation of TSTA (Tritium Systems Test Assembly), preliminary design work of blanket tritium system for lithium ceramic blanket, aqueous solution blanket and liquid metal blanket, have been performed to investigate technical feasibility of tritium demonstration tests using the TSTA. Detail study of the aqueous solution blanket concept have not been performed in the Japanese fusion program, so that this study was carried out to investigate features of its concept and to evaluated its technical problems. The following are the major items studied in the present work: (i) Neutronics of tritium breeding ratio and shielding performance Lithium concentration, Li-60 enrichment, beryllium or lead, composition of structural material/beryllium/solution, heavy water, different lithium-salts (ii) Physicochemical properties of salts Solubility, corrosion characteristics and compatibility with structural materials, radiolysis (iii) Estimation of radiolysis in ITER aqueous solution blanket. (author)

  11. Preformulation study of methazolamide for topical ophthalmic delivery: physicochemical properties and degradation kinetics in aqueous solutions.

    Science.gov (United States)

    Jiang, Sunmin; Wang, Fengzhen; Zhu, Shuning; Zhang, Xiumei; Guo, Zhigang; Li, Rui; Xu, Qunwei

    2013-05-20

    Methazolamide (MTZ) is an anti-glaucoma drug. The present paper aims to characterize the physicochemical properties and degradation kinetics of MTZ to provide a basis for topical ophthalmic delivery. With the increase in pH (pH 5.5-8.0) of aqueous solution, the solubility of the compound increased while the partition coefficient (Ko/w) which was estimated in the system n-octanol/aqueous solution decreased. The degradation of MTZ in aqueous solution followed pseudo-first-order kinetic. The degradation rate kpH is the rate in the absence of buffer catalysis. Plotting the natural logarithm of kpH versus the corresponding pH value gave a V-shaped pH-rate profile with a maximum stability at pH 5.0. The degradation rate constants as a function of the temperature obeyed the Arrhenius equation (R(2)=0.9995 at pH 7.0 and R(2)=0.9955 at pH 9.0, respectively). A decrease in ionic strength and buffer concentration displayed a stabilizing effect on MTZ. Buffer species also influenced the MTZ hydrolysis. Phosphate buffer system was more catalytic than tris and borate buffer systems. In brief, it is important to consider the physicochemical properties and the stability of MTZ during formulation. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. NIR spectroscopic properties of aqueous acids solutions.

    Science.gov (United States)

    Omar, Ahmad Fairuz; Atan, Hanafi; Matjafri, Mohd Zubir

    2012-06-15

    Acid content is one of the important quality attributes in determining the maturity index of agricultural product, particularly fruits. Despite the fact that much research on the measurement of acidity in fruits through non-destructive spectroscopy analysis at NIR wavelengths between 700 to 1,000 nm has been conducted, the same response towards individual acids is not well known. This paper presents NIR spectroscopy analysis on aqueous citric, tartaric, malic and oxalic solutions through quantitative analysis by selecting a set of wavelengths that can best be used to measure the pH of the solutions. The aquaphotomics study of the acid solutions has generated R² above 0.9 for the measurement of all acids. The most important wavelengths for pH are located at 918-925 nm and 990-996 nm, while at 975 nm for water.

  13. A thermodynamic model for aqueous solutions of liquid-like density

    Energy Technology Data Exchange (ETDEWEB)

    Pitzer, K.S.

    1987-06-01

    The paper describes a model for the prediction of the thermodynamic properties of multicomponent aqueous solutions and discusses its applications. The model was initially developed for solutions near room temperature, but has been found to be applicable to aqueous systems up to 300/sup 0/C or slightly higher. A liquid-like density and relatively small compressibility are assumed. A typical application is the prediction of the equilibrium between an aqueous phase (brine) and one or more solid phases (minerals). (ACR)

  14. Measurement of properties of a lithium bromide aqueous solution for the determination of the concentration for a prototype absorption machine

    International Nuclear Information System (INIS)

    Labra, L.; Juárez-Romero, D.; Siqueiros, J.; Coronas, A.; Salavera, D.

    2017-01-01

    Highlights: • Determination of concentration of absorption mixture for absorption heat transformers. • Measurement of physical properties for heat transformer assessment. • Comparative behavior of Electric conductivity, Refractive index, and density of LiBr-H_2O. - Abstract: An electrolyte solution of Lithium Bromide (LiBr) water was chosen for study because of its wide use in prototype absorption machines. The LiBr must be operated close to the temperature and mass fraction at which lithium bromide achieves the highest efficiency. For the purpose of establishing the concentration in a prototype absorption machines, measurements were made of the properties that vary with temperature and concentration. The selected properties are electrical conductivity, density, refractive indexes and sound velocity. The resulting measured properties values were compared with some values found in previous works. The properties of aqueous lithium bromide solutions were measured at the concentration range of 45–65% of LiBr and temperatures range of 20–80 °C. Semi-empirical correlations that determine the properties of lithium bromide are also proposed. The methods for measuring the properties of aqueous solutions were considered taking into account their reliability, simplicity and sampling time.

  15. Synthesis and Rheological Properties of an Associative Star Polymer in Aqueous Solutions

    DEFF Research Database (Denmark)

    Hietala, Sami; Mononen, Pekka; Strandman, Satu

    2007-01-01

    synthesised by atom transfer radical. polymerization (ATRP) was found to fonn hydrogels at room temperature at polymer concentrations. Cp, over 22 gIL due to the interpolymer drophobic association of the PS blocks. Increasing Cp leads to stronger elastic networks at room temperature that show a gel......Rheological properties of aqueous solutions and hydrogels fonned by an amphiphiIic star block copolymer poly(acrylic acid)-blockpolystyrene (PAAS4-b-PS6)4. were investigated as a function of the polymer concentration (Cp), temperature, and added saIt concentration. The water-soluble polymer......-to-solution transition with increasing temperature. Increase of ionic strength decreases the moduli compared with the pure hydrogel but did not affect the gel-sol transition temperature significantly. Small-angle X-ray experiments showed two distinct scattering correlation peaks for samples above the gelling Cp, which...

  16. Assembly of DNA Architectures in a Non-Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Thomas J. Proctor

    2012-08-01

    Full Text Available In the present work, the procedures for the creation of self-assembled DNA nanostructures in aqueous and non-aqueous media are described. DNA-Surfactant complex formation renders the DNA soluble in organic solvents offering an exciting way to bridge the transition of DNA origami materials electronics applications. The DNA retains its structural features, and these unique geometries provide an interesting candidate for future electronics and nanofabrication applications with potential for new properties. The DNA architectures were first assembled under aqueous conditions, and then characterized in solution (using circular dichroism (CD spectroscopy and on the surface (using atomic force microscopy (AFM. Following aqueous assembly, the DNA nanostructures were transitioned to a non-aqueous environment, where butanol was chosen for optical compatibility and thermal properties. The retention of DNA hierarchical structure and thermal stability in non-aqueous conditions were confirmed via CD spectroscopy. The formation and characterization of these higher order DNA-surfactant complexes is described in this paper.

  17. Influence of starch origin on rheological properties of concentrated aqueous solutions

    Directory of Open Access Journals (Sweden)

    Stojanović Željko P.

    2011-01-01

    Full Text Available The rheological properties of corn and potato starch concentrated aqueous solutions were investigated at 25ºC. The starches were previously dispersed in water and the solutions were obtained by heating of dispersions at 115-120ºC for 20 minutes. The solutions of potato starch were transparent, while the corn starch solutions were opalescent. The results of dynamic mechanical measurements showed that the values of viscosity, h, storage modulus, G′, and loss modulus, G″, of the corn starch solutions increased with the storage time. This phenomenon was not observed for the potato starch solutions. It was assumed that the increase of h, G′ and G″ is the result of starch solutions retrogradation. The potato starch solutions retrogradation did not occur probably because of the phosphates presence. The viscosity of 2 mass % corn starch solution is less than the viscosity of 2 mass % potato starch solution. By increasing the concentration of corn starch solution the gel with elastic behavior was formed. The corn starch solutions formed gel as early as at 4 mass % concentration, while potato starch solutions achieved the gel state at the concentration of 5 mass %. The value of exponent m (G′ and G″ µ wm during the transition of potato starch solutions to gel is 0.414, which gives the fractal dimensions for corn starch of 2.10. The obtained value of fractal dimension corresponds to slow aggregation. The corn starch solutions with the starch concentrations higher than 4 mass % form weak gels. For these solutions the values of modulus in rubber plateau were determined. It was found that the modulus in rubber plateau increased with the concentration by the exponent of 4.36. Such high exponent value was obtained in the case when the tridimensional network is formed, i.e. when supermolecular structures like associates or crystal domains are formed.

  18. Analysis and modeling of alkali halide aqueous solutions

    DEFF Research Database (Denmark)

    Kim, Sun Hyung; Anantpinijwatna, Amata; Kang, Jeong Won

    2016-01-01

    on calculations for various electrolyte properties of alkali halide aqueous solutions such as mean ionic activity coefficients, osmotic coefficients, and salt solubilities. The model covers highly nonideal electrolyte systems such as lithium chloride, lithium bromide and lithium iodide, that is, systems...

  19. Lanthanide complexation in aqueous solutions

    International Nuclear Information System (INIS)

    Choppin, G.R.

    1984-01-01

    The lanthanide elements form an extended series of cations with the same charge, slightly varying radii and useful magnetic and spectroscopic properties. Their use in technology is growing rapidly as their properties are more fully explored. The lanthanides also offer scientists valuable and often unique probes for investigating a variety of chemical and physical phenomena. This review has attempted to call attention to these latter uses without trying to provide a thorough discussion of all the relevant literature. Hopefully, awareness of the more interesting facets of present studies of lanthanide complexes in aqueous solution will spur even more advances in the use of these elements. (Auth.)

  20. Photophysical properties of betaxanthins: Vulgaxanthin I in aqueous and alcoholic solutions

    Energy Technology Data Exchange (ETDEWEB)

    Wendel, Monika [Quantum Electronics Laboratory, Faculty of Physics, Adam Mickiewicz University in Poznan, Umultowska 85, Poznan 61-614 (Poland); Szot, Dominika; Starzak, Karolina; Tuwalska, Dorota [Faculty of Chemical Engineering and Technology, Institute C-1, Section of Analytical Chemistry, Cracow University of Technology, Warszawska 24, Cracow 31-155 (Poland); Gapinski, Jacek [Molecular Biophysics Department, Faculty of Physics, Adam Mickiewicz University in Poznan, Umultowska 85, Poznan 61-614 (Poland); Naskrecki, Ryszard [Quantum Electronics Laboratory, Faculty of Physics, Adam Mickiewicz University in Poznan, Umultowska 85, Poznan 61-614 (Poland); Prukala, Dorota; Sikorski, Marek [Faculty of Chemistry, Adam Mickiewicz University in Poznan, Umultowska 89b, Poznan 61-614 (Poland); Wybraniec, Slawomir [Faculty of Chemical Engineering and Technology, Institute C-1, Section of Analytical Chemistry, Cracow University of Technology, Warszawska 24, Cracow 31-155 (Poland); Burdzinski, Gotard, E-mail: gotardb@amu.edu.pl [Quantum Electronics Laboratory, Faculty of Physics, Adam Mickiewicz University in Poznan, Umultowska 85, Poznan 61-614 (Poland)

    2015-11-15

    Betaxanthins are yellow pigments present in Caryophyllales plants and some higher fungi. We characterize photophysical properties of vulgaxanthin I and extracts of Amanita muscaria L. Vulgaxanthin I photoexcitation at λ{sub exc}=476 nm leads to the S{sub 1} excited state with the S{sub 1}→S{sub n} absorption bands at ca. 390 and 920 nm in both aqueous and alcoholic solutions. The S{sub 1} state lifetimes (2.9 and 37 ps in water) imply that vulgaxanthin I exists in two stereoisomeric forms. An increase in the solvent viscosity extends the S{sub 1} lifetimes and fluorescence quantum yields, probably due to hindered internal rotations in the dye. Internal conversion is the major S{sub 1} state deactivation path, with fluorescence being a minor channel, and S{sub 1}→T{sub 1} intersystem crossing not observed. Betaxanthins extracted from A. muscaria L. have similar properties. Efficient dissipation of the absorbed light energy as heat supports the postulate of photoprotective role of betaxanthins in vivo. - Highlights: • Betaxanthin S{sub 1} state deactivation mechanism is mainly radiationless. • S{sub 1} state shows absorption band with maxima at about 390 nm and 920 nm. • Solvent viscosity affects S{sub 1} state lifetime and fluorescence quantum yield. • Addition of potassium iodide to solution enhances ISC in betaxanthin.

  1. Volumetric properties of aqueous solutions of glutaric acid

    International Nuclear Information System (INIS)

    Ben-Hamo, Meyrav; Apelblat, Alexander; Manzurola, Emanuel

    2007-01-01

    Densities of aqueous solutions with molalities up to 6 mol . kg -1 were determined at 5 K temperature intervals, from T = 288.15 K to T = 333.15 K. Densities served to evaluate the apparent molar volumes, V 2,φ (m, T), the cubic expansion coefficients, α(m, T), and the changes of isobaric heat capacities with respect to pressure, (∂C P /∂P) T,m . They were qualitatively correlated with the changes in the structure of water when glutaric acid is dissolved in it

  2. The influence of surface modification, coating agents and pH value of aqueous solutions on physical properties of magnetite nanoparticles investigated by ESR method

    Energy Technology Data Exchange (ETDEWEB)

    Dobosz, Bernadeta, E-mail: benia@amu.edu.pl [Medical Physics Division, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland); Krzyminiewski, Ryszard [Medical Physics Division, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland); Kurczewska, Joanna; Schroeder, Grzegorz [Faculty of Chemistry, Adam Mickiewicz University, Umultowska 89B, 61-614 Poznań (Poland)

    2017-05-01

    The article presents the results of electron spin resonance (ESR) studies for aqueous solutions of functionalized superparamagnetic iron(II,III) oxide nanoparticles. The samples studied differed in type of organic ligands at the magnetite surface, type of coating agent and pH value of aqueous solutions. The ESR spectra of the samples were obtained at room temperature and at 230 K. The field cooling (FC) experiment was performed for selected samples, and the effective anisotropy field (H{sub K2}) and the first order magnetocrystalline anisotropy constant (K{sub 1}) was calculated. The process of the nanoparticles diffusion in different environments (human blood, human serum) forced by an inhomogeneous magnetic field was monitored and their interactions with different solvents have been discussed. It has been shown that ESR method is useful to observe the impact of organic ligands at the magnetite surface, type of coating agent and pH value of aqueous solutions on the properties of iron(II,III) oxide nanoparticles. - Highlights: • The influence of different organic ligands, coatings and pH values of aqueous solutions on the physical properties of the magnetite nanoparticles studied by ESR method. • Nanoparticles diffusion forced by inhomogeneous magnetic field monitored by ESR and explained. • A narrow line separated in ESR spectra by CREM. • The influence of different coatings and pH values of aqueous solutions on ESR spectra of TEMPO attached to the magnetite core.

  3. Volumetric properties of aqueous solutions of glutaric acid

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Hamo, Meyrav [Department of Chemical Engineering, Ben Gurion University of the Negev, P.O. Box 653, Beer Sheva 84105 (Israel); Apelblat, Alexander [Department of Chemical Engineering, Ben Gurion University of the Negev, P.O. Box 653, Beer Sheva 84105 (Israel)]. E-mail: apelblat@bgu.ac.il; Manzurola, Emanuel [Department of Chemical Engineering, Ben Gurion University of the Negev, P.O. Box 653, Beer Sheva 84105 (Israel)

    2007-07-15

    Densities of aqueous solutions with molalities up to 6 mol . kg{sup -1} were determined at 5 K temperature intervals, from T = 288.15 K to T = 333.15 K. Densities served to evaluate the apparent molar volumes, V {sub 2,{phi}}(m, T), the cubic expansion coefficients, {alpha}(m, T), and the changes of isobaric heat capacities with respect to pressure, ({partial_derivative}C {sub P}/{partial_derivative}P) {sub T,m}. They were qualitatively correlated with the changes in the structure of water when glutaric acid is dissolved in it.

  4. Sound velocity in potassium hydroxide aqueous solution

    International Nuclear Information System (INIS)

    Tsapuryan, Kh.D.; Aleksandrov, A.A.; Kochetkov, A.I.

    1992-01-01

    Measurements of ultrasonic velocities in potassium hydroxide aqueous solutions are carried out within the frames of studies on improvement of water chemistry in NPP cooling systems. Method of echo pulses superposition with acoustic path length of 41.447 mm is used for measurements. The measurements are performed at 2.6 MHz frequency. Complex temperature dependence of ultrasonic velocity is determined. Ultrasonic velocity dependence on pressure is close to linear one. The formula for calculation of thermodynamic properties of the studied solutions on the basis of experimental data obtained is proposed

  5. Self-assembly of block copolymer micelles: synthesis via reversible addition-fragmentation chain transfer polymerization and aqueous solution properties.

    Science.gov (United States)

    Mya, Khine Y; Lin, Esther M J; Gudipati, Chakravarthy S; Gose, Halima B A S; He, Chaobin

    2010-07-22

    Poly(hexafluorobutyl methacrylate) (PHFBMA) homopolymer was synthesized by reversible addition-fragmentation chain transfer (RAFT)-mediated living radical polymerization in the presence of cyano-2-propyl dithiobenzoate (CPDB) RAFT agent. A block copolymer of PHFBMA-poly(propylene glycol acrylate) (PHFBMA-b-PPGA) with dangling poly(propylene glycol) (PPG) side chains was then synthesized by using CPDB-terminated PHFBMA as a macro-RAFT agent. The amphiphilic properties and self-assembly of PHFBMA-b-PPGA block copolymer in aqueous solution were investigated by dynamic and static light scattering (DLS and SLS) studies, in combination with fluorescence spectroscopy and transmission electron microscopy (TEM). Although PPG shows moderately hydrophilic character, the formation of nanosize polymeric micelles was confirmed by fluorescence and TEM studies. The low value of the critical aggregation concentration exhibited that the tendency for the formation of copolymer aggregates in aqueous solution was very high due to the strong hydrophobicity of the PHFBMA(145)-b-PPGA(33) block copolymer. The combination of DLS and SLS measurements revealed the existence of micellar aggregates in aqueous solution with an association number of approximately 40 +/- 7 for block copolymer micelles. It was also found in TEM observation that there are 40-50 micelles accumulated into one aggregate and these micelles are loosely packed inside the aggregate.

  6. Volumetric property of glycine, L-serine, L-alanine and L-proline in aqueous solutions of 1-phenylpiperazinium tetrafluoroborate

    International Nuclear Information System (INIS)

    Xie, Hujun; Zhao, Lijiang; Liu, Chengcheng; Cao, Yifan; Lu, Xiaoxing; Lei, Qunfang; Fang, Wenjun

    2016-01-01

    Highlights: • Volumetric property of four amino acids in aqueous solutions of [Phpi][BF_4] were measured. • The standard partial molar volume, transparent partial molar volume and hydration number were calculated. • [Phpi][BF_4] interacts strongly with four kinds of amino acids. • Hydrophilic–hydrophobic and hydrophobic–hydrophobic interactions play the dominant roles in ternary systems. • The ternary systems are generated via multiple hydrogen bond interactions. - Abstract: The densities of aqueous solutions of glycine, L-serine, L-alanine, L-proline with the ionic liquid (IL), 1-phenylpiperazinium tetrafluoroborate ([Phpi][BF_4]) at the IL concentrations of (0.025, 0.055 and 0.100) mol·kg"−"1 have been measured at the temperatures of (298.15, 303.15 and 308.15) K. On the basis of the experimental results, the apparent molar volume (V_Φ), standard partial molar volume (V_Φ"0), transfer partial molar volume (Δ_t_rV_Φ"0) and hydration number (n_H) have been calculated. The hydrophilic–hydrophilic, hydrophobic–hydrophilic and hydrophobic–hydrophobic interactions are involved in the studied systems of {[Phpi][BF_4] + amino acids + H_2O. These volumetric parameters can help to understand the mixing effects and other complex biological processes between amino acids and ionic liquid aqueous solution.

  7. Quenching characteristics of bathocuproinedisulfonic acid, disodium salt in aqueous solution and copper sulfate plating solution

    Science.gov (United States)

    Koga, Toshiaki; Hirakawa, Chieko; Takeshita, Michinori; Terasaki, Nao

    2018-04-01

    Bathocuproinedisulfonic acid, disodium salt (BCS) is generally used to detect Cu(I) through a color reaction. We newly found BCS fluorescence in the visible blue region in an aqueous solution. However, the fluorescence mechanism of BCS is not well known, so we should investigate its fundamental information. We confirmed that the characteristics of fluorescence are highly dependent on the molecular concentration and solvent properties. In particular, owing to the presence of the copper compound, the fluorescence intensity extremely decreases. By fluorescence quenching, we observed that a copper compound concentration of 10-6 mol/L or less could easily be measured in an aqueous solution. We also observed BCS fluorescence in copper sulfate plating solution and the possibility of detecting monovalent copper by fluorescence reabsorption.

  8. Structure of water and the thermodynamics of aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Nemethy, G.

    1970-10-26

    This report represents the summary of a series of lectures held at the Istituto Superiore di Sanita, Laboratori di Fisica, from 18 September to 26 October 1970. The topics discussed were: Intermolecular forces, the individual water molecule and the hydrogen bond, the structures of the solid phases of water, experimental information on the strucuture of liquid water, theoretical models of water structure, experimental properties and theoretical models of aqueous solutions of nonpolar solutes, polar solutes, and electrolytes, the conformational stability of biological macromolecules.

  9. [Enhancement effect of double-beam laser processed aqueous solution on ICP emission spectrum].

    Science.gov (United States)

    Chen, Jin-zhong; Xu, Li-jing; Su, Hong-xin; Li, Xu; Wang, Shu-fang

    2015-01-01

    In order to change the physical properties of aqueous solution and improve the radiation intensity of the ICP emission spectrum, the effects of different laser power density and irradiation time on the surface tension and viscosity of aqueous solution were investigated by using near infrared laser at 976 nm and CO2 laser at 10. 6 µm to irradiate aqueous solution orthogonally, then the enhancement of ICP spectral intensity with processed solution was discussed. The results showed that the surface tension and viscosity of aqueous solution reduced by 42. 13% and 14. 03% compared with the untreated, and the atomization efficiency increased by 51.26% at the laser power density 0. 265 7 W . cm-2 of 976 nm and 0. 206 9 W . cm-2 of CO2 laser with 40 min irradiation time. With the optimized aqueous solution introduced into the ICP source, the spectral line intensity of sample elements As, Cd, Cr, Hg and Pb was enhanced by 46.29%, 94. 65%, 30. 76%, 33.07% and 94. 58% compared to the untreated aqueous solution, while the signal-to-background ratio increased by 43. 84%, 85. 35%, 28. 71%, 34. 37% and 90. 91%, respectively. Plasma temperature and electron density also increased by 5. 94% and 1. 18% respectively. It is obvious that the method of double-beam laser orthogonal irradiation on solution can reduce the surface tension and viscosity of aqueous solution significantly, and raise the radiationintensity of ICP source, and will provide a better condition for detecting the trace heavy metal elements in water samples.

  10. MWCNTs/Cellulose Hydrogels Prepared from NaOH/Urea Aqueous Solution with Improved Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Yingpu Zhang

    2015-01-01

    Full Text Available Novel high strength composite hydrogels were designed and synthesized by introducing multiwalled carbon nanotubes (MWCNTs into cellulose/NaOH/urea aqueous solution and then cross-linked by epichlorohydrin. MWCNTs were used to modify the matrix of cellulose. The structure and morphology of the hydrogels were characterized by Fourier transform infrared (FT-IR spectroscopy, high resolution transmission electron microscopy (HR-TEM, and scanning electron microscopy (SEM. The results from swelling testing revealed that the equilibrium swelling ratio of hydrogels decreased with the increment of MWCNTs content. Thermogravimetric analysis (TGA and dynamic mechanical analysis (DMA results demonstrated that the introduction of MWCNT into cellulose hydrogel networks remarkably improved both thermal and mechanical properties of the composite hydrogels. The preparation of MWCNTs modifiedcellulose-based composites with improved mechanical properties was the first important step towards the development of advanced functional materials.

  11. Characteristics of regenerated nanocellulosic fibers from cellulose dissolution in aqueous solutions for wood fiber/polypropylene composites

    Science.gov (United States)

    Sangyeob Lee; Hui Pan; Chung Y. Hse; Alfred R. Gunasekaran; Todd F. Shupe

    2014-01-01

    The effects of aqueous solutions were evaluated on the properties of regenerated cellulosic nanofibers prepared from pure cellulose fibers in various formulations of aqueous solutions. Thermoplastic composites were prepared with reinforcement of the regenerated cellulosic nanofibers. The regenerated cellulosic fibers from cellulosic woody biomass were obtained from...

  12. Osmotic potential calculations of inorganic and organic aqueous solutions over wide solute concentration levels and temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Cochrane, T. T., E-mail: agteca@hotmail.com [AGTECA S.A., 230 Oceanbeach Road, Mount Maunganui, Tauranga 3116 (New Zealand); Cochrane, T. A., E-mail: tom.cochrane@canterbury.ac.nz [Department of Civil and Natural Resources Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140 (New Zealand)

    2016-01-15

    Purpose: To demonstrate that the authors’ new “aqueous solution vs pure water” equation to calculate osmotic potential may be used to calculate the osmotic potentials of inorganic and organic aqueous solutions over wide ranges of solute concentrations and temperatures. Currently, the osmotic potentials of solutions used for medical purposes are calculated from equations based on the thermodynamics of the gas laws which are only accurate at low temperature and solute concentration levels. Some solutions used in medicine may need their osmotic potentials calculated more accurately to take into account solute concentrations and temperatures. Methods: The authors experimented with their new equation for calculating the osmotic potentials of inorganic and organic aqueous solutions up to and beyond body temperatures by adjusting three of its factors; (a) the volume property of pure water, (b) the number of “free” water molecules per unit volume of solution, “N{sub f},” and (c) the “t” factor expressing the cooperative structural relaxation time of pure water at given temperatures. Adequate information on the volume property of pure water at different temperatures is available in the literature. However, as little information on the relative densities of inorganic and organic solutions, respectively, at varying temperatures needed to calculate N{sub f} was available, provisional equations were formulated to approximate values. Those values together with tentative t values for different temperatures chosen from values calculated by different workers were substituted into the authors’ equation to demonstrate how osmotic potentials could be estimated over temperatures up to and beyond bodily temperatures. Results: The provisional equations formulated to calculate N{sub f}, the number of free water molecules per unit volume of inorganic and organic solute solutions, respectively, over wide concentration ranges compared well with the calculations of N{sub f

  13. Osmotic potential calculations of inorganic and organic aqueous solutions over wide solute concentration levels and temperatures

    International Nuclear Information System (INIS)

    Cochrane, T. T.; Cochrane, T. A.

    2016-01-01

    Purpose: To demonstrate that the authors’ new “aqueous solution vs pure water” equation to calculate osmotic potential may be used to calculate the osmotic potentials of inorganic and organic aqueous solutions over wide ranges of solute concentrations and temperatures. Currently, the osmotic potentials of solutions used for medical purposes are calculated from equations based on the thermodynamics of the gas laws which are only accurate at low temperature and solute concentration levels. Some solutions used in medicine may need their osmotic potentials calculated more accurately to take into account solute concentrations and temperatures. Methods: The authors experimented with their new equation for calculating the osmotic potentials of inorganic and organic aqueous solutions up to and beyond body temperatures by adjusting three of its factors; (a) the volume property of pure water, (b) the number of “free” water molecules per unit volume of solution, “N f ,” and (c) the “t” factor expressing the cooperative structural relaxation time of pure water at given temperatures. Adequate information on the volume property of pure water at different temperatures is available in the literature. However, as little information on the relative densities of inorganic and organic solutions, respectively, at varying temperatures needed to calculate N f was available, provisional equations were formulated to approximate values. Those values together with tentative t values for different temperatures chosen from values calculated by different workers were substituted into the authors’ equation to demonstrate how osmotic potentials could be estimated over temperatures up to and beyond bodily temperatures. Results: The provisional equations formulated to calculate N f , the number of free water molecules per unit volume of inorganic and organic solute solutions, respectively, over wide concentration ranges compared well with the calculations of N f using recorded

  14. Montmorillonite surface properties and sorption characteristics for heavy metal removal from aqueous solutions

    International Nuclear Information System (INIS)

    Ijagbemi, Christianah Olakitan; Baek, Mi-Hwa; Kim, Dong-Su

    2009-01-01

    Surface properties of montmorillonite (MMT) and its adsorption characteristics for heavy metals have been investigated with nickel and copper as sorbate from aqueous solutions. Employing the potentiometric and mass titration techniques in batch experimental methods, the point of zero charge (PZC) and point of zero net proton charge (PZNPC) of MMT edges at different ionic strengths present pH PZC and pH PZNPC to be 3.4 ± 0.2. A crossing point was observed for the proton adsorption vs. pH curves at different ionic strengths of KCl electrolyte and in investigating MMT remediation potentialities as sorbent for heavy metals polluted waters, the effects of heavy metal concentration, pH, MMT dosage, reaction time and temperature for Cu 2+ and Ni 2+ uptake were studied. The sorption of metal ions by MMT was pH dependent and the adsorption kinetics revealed sorption rate could be well fitted by the pseudo-second-order rate model. The data according to mass transfer and intraparticle diffusion models confirmed diffusion of solutes inside the clay particles as the rate-controlling step and more important for the adsorption rate than the external mass transfer. Adsorption isotherms showed that the uptake of Cu 2+ and Ni 2+ could be described by the Langmuir model and from calculations on thermodynamic parameters, the positive ΔG o values at different temperatures suggest that the sorption of both metal ions were non-spontaneous. Change in enthalpy (ΔH o ) for Ni 2+ and Cu 2+ were 28.9 and 13.27 kJ/mol K respectively, hence an endothermic diffusion process, as ion uptake increased with increase in temperature. Values of ΔS o indicate low randomness at the solid/solution interface during the uptake of both Cu 2+ and Ni 2+ by MMT. Montmorillonite has a considerable potential for the removal of heavy metal cationic species from aqueous solution and wastewater.

  15. Study of the physicochemical properties of the interface between titanium dioxide and various aqueous solutions

    International Nuclear Information System (INIS)

    Mazilier, C.

    1988-01-01

    The aim of this work is the study of ion exchange capacity of titanium dioxide in view of high temperature water purification and radioactive effluent processing because of its resistance to heat and radiations. Titanium dioxide is obtained by alkaline hydrolysis of an aqueous solution of Ti (IV) and is characterized by analytical physical chemistry methods. Interface between Ti0 2 and simple aqueous solutions (electrolytes) is more particularly studied by potentiometry [fr

  16. Physical Properties and Thermal Decomposition of Aqueous Solutions of 2-Amino-2-hydroxymethyl-1, 3-propanediol (AHPD)

    Science.gov (United States)

    Murshid, Ghulam; Shariff, Azmi Mohd; Lau, K. K.; Bustam, Mohammad Azmi; Ahmad, Faizan

    2011-10-01

    Physical properties such as density, viscosity, refractive index, surface tension, and thermal stability of 2-amino-2-hydroxymethyl-1,3-propanediol (AHPD) were experimentally measured. All the experimental measurements were made over a wide range of temperatures from (298.15 to 333.15) K and AHPD concentrations of (1, 7, 13, 19, and 25) mass%. An overall decrease in all the measured physical properties was observed with increasing temperature. The experimental results are presented as a function of temperature and AHPD mass fraction. All the measured physical properties were correlated as a function of temperature. Thermal decomposition of pure and aqueous solutions of AHPD was investigated using a thermo-gravimetric analyzer (TGA) at a heating rate of 10 K · min-1.

  17. Fluorescence of aqueous solutions of commercial humic products

    Science.gov (United States)

    Gosteva, O. Yu.; Izosimov, A. A.; Patsaeva, S. V.; Yuzhakov, V. I.; Yakimenko, O. S.

    2012-01-01

    We have studied the spectral luminescence characteristics of aqueous solutions of humic products obtained from different raw material sources, and their behavior as the excitation wavelength increases from 270 nm to 355 nm. We have identified differences in the spectral properties of industrial humic products from coalified materials, lignin-containing organic waste, and humic products from plant raw material (peat, sapropel, vermicompost). We have shown that humic products from plant raw material have spectral properties closer to those for humic substances in natural water or soil than humic products from coalified materials.

  18. Radiation-induced nitration of organic compounds in aqueous solutions

    International Nuclear Information System (INIS)

    Ershov, B.G.; Gordeev, A.V.; Bykov, G.L.; Moisy, P.

    2012-01-01

    Radiolysis in aqueous nitrate and acetic acid solutions and nitrate/nitric acid and phenol was studied. The radiolysis of these solutes occurs with circle NO 2 radical, which is the active nitrating agent. Accumulation of nitromethane and nitrite was determined during γ-irradiation of aqueous solutions containing acetic and nitrate solutions. Irradiation of aqueous phenol-nitrate/nitric acid solutions results in the formation of 2- and 4-nitrophenols.

  19. Radiation-induced nitration of organic compounds in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Ershov, B.G.; Gordeev, A.V.; Bykov, G.L. [Russian Academy of Sciences, Moscow (Russian Federation). Frumkin Inst. of Physical Chemistry and Electrochemistry; Moisy, P. [CEA, Bagnols sur Ceze (France). Nuclear Energy Div.

    2012-07-01

    Radiolysis in aqueous nitrate and acetic acid solutions and nitrate/nitric acid and phenol was studied. The radiolysis of these solutes occurs with {sup circle} NO{sup 2} radical, which is the active nitrating agent. Accumulation of nitromethane and nitrite was determined during {gamma}-irradiation of aqueous solutions containing acetic and nitrate solutions. Irradiation of aqueous phenol-nitrate/nitric acid solutions results in the formation of 2- and 4-nitrophenols.

  20. The immiscible aqueous solutions of alkyl phosphates. Study for the purpose of uranium extraction from phosphoric acid solutions

    International Nuclear Information System (INIS)

    Mauborgne, Bernard

    1979-01-01

    Systems of immiscible aqueous solutions composed by a phase rich in mineral salt and by another phase almost totally containing an organic salt, have been studied for years, with quaternary ammonium salts with an organic cation. The objective of this research is to study systems symmetric to the previous ones, i.e. with organic anions such as alkyl phosphates, and then to try to understand mechanisms of extraction of metals in these environments. Based on properties of immiscible aqueous solutions, an original three-phase process of liquid-liquid extraction has been developed, and is used to separate uranium in phosphoric acids with better performance than the existing industrial processes [fr

  1. Optical and photophysical properties of the chlorin-type photosensitizer photolon in aqueous solutions of different acidities

    Science.gov (United States)

    Bagrov, I. V.; Belousova, I. M.; Dadeko, A. V.; Krisko, T. K.; Kriukova, E. V.; Martynenko, I. V.; Savchenko, M. R.

    2017-09-01

    Photolon is a modern compound for fluorescence diagnostics and photodynamic therapy, which was relatively recently introduced into clinical practice. In the present work, we study its electronic-absorption spectra, fluorescence spectra (excited at different visible wavelengths), and fluorescence quantum yields. The characteristics are studied in aqueous solutions with pH 6.0-7.5 and compared under identical conditions with the corresponding characteristics of other chlorin- or porphyrin-type compounds (Photoditazin, Radachlorin, Dimegin) for photodynamic diagnostics and therapy. It is shown that the studied properties of Photolon are very close to those of Photoditazin and Radachlorin. At the same time, chlorin products are found to be more effective than Dimegin at pH 7.5, which is close to the pH of blood, while Dimegin is the most effective in solutions with lower pH, for example, in distilled water.

  2. Preparation and characterization of novel PVDF nanofiltration membranes with hydrophilic property for filtration of dye aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Nikooe, Naeme, E-mail: naeme.nikooe@stu.um.ac.ir; Saljoughi, Ehsan, E-mail: saljoughi@um.ac.ir

    2017-08-15

    Highlights: • Preparation of novel PVDF nanofiltration membranes with noticeable hydrophilicity. • Simultaneous achievement of hydrophilicity and dye removal via addition of Brij-58. • In situ modification and stability of hydrophilic property via addition of Brij-58. - Abstract: In the present research, for the first time PVDF/Brij-58 blend nanofiltration membranes with remarkable performance in filtration of dye aqueous solution were prepared via immersion precipitation. A noticeable improvement in water permeation and fouling resistance of the PVDF membranes was achieved by using Brij-58 surfactant as a hydrophilic additive. Scanning electron microscopy (SEM), fourier transform infrared spectroscopy (FT-IR) and water contact angle were applied for the investigation of membrane morphology, detection of the surface chemical composition and relative hydrophilicity/hydrophobicity, respectively. The membrane performance was studied and compared by determination of pure water flux (PWF) and filtration of synthetic reactive dye aqueous solutions as well as bovine serum albumin (BSA) as foulant model. It was found out that addition of 4 wt.% Brij-58 to the casting solution results in formation of membrane with remarkable hydrophilicity and fouling resistance (contact angle of 46° and flux recovery ratio (FRR) = 90%), higher porosity and consequently noticeable PWF (31.2 L/m{sup 2} h) and recognized dye rejection value (90%) in comparison with the pristine PVDF nanofiltration membrane. Addition of Brij-58 surfactant to the casting solution resulted in formation of NF membrane with higher hydrophilicity and permeability as well as higher dye rejection value in comparison with the addition of PEG 400 additive.

  3. Influence of Monomer Concentration on the Morphologies and Electrochemical Properties of PEDOT, PANI, and PPy Prepared from Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Shalini Kulandaivalu

    2016-01-01

    Full Text Available Poly(3,4-ethylenedioxyhiophene (PEDOT, polyaniline (PANI, and polypyrrole (PPy were prepared on indium tin oxide (ITO substrate via potentiostatic from aqueous solutions containing monomer and lithium perchlorate. The concentration of monomers was varied between 1 and 10 mM. The effects of monomer concentration on the polymers formation were investigated and compared by using Fourier transform infrared spectroscopy (FTIR, Raman spectroscopy, scanning electron microscopy (SEM, cyclic voltammetry (CV, and electrochemical impedance spectroscopy (EIS measurements. FTIR and Raman spectra showed no changes in the peaks upon the increment of the concentration. Based on the SEM images, the increment in monomer concentration gives significant effect on morphologies and eventually affects the electrochemical properties. PEDOT electrodeposited from 10 mM solution showed excellent electrochemical properties with the highest specific capacitance value of 12.8 mF/cm2.

  4. Influence of H/D isotope substitution on physicochemical properties of aqueous solutions of urea and thiourea

    International Nuclear Information System (INIS)

    Jelinska-Kazimierczuk, M.; Szydlowski, J.

    2001-01-01

    The influence of the H/D isotope substitution on excess volumes, partial molar volumes, viscosity and ultrasound speed in aqueous solutions of urea and thiourea are studied at 20 o C. The excess volume of the solutions studied is relatively small - however, it is negative in urea and positive in thiourea solutions. On the other hand, the deuteration affects the excess volume in both solutions in the same way: deuterated systems show smaller deviation from additivity than regular ones. The speed of sound in the systems studied increases monotonously with concentration , but its isotope effect decreases as the concentration increases. The curves of viscosity are monotonous too, but isotope effect of kinematic viscosity is practically the same in the whole concentration range studied. The present results for urea and thiourea aqueous solutions are compared with those previously obtained for amide- water systems. (author)

  5. 21 CFR 524.1200b - Kanamycin ophthalmic aqueous solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Kanamycin ophthalmic aqueous solution. 524.1200b... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1200b Kanamycin ophthalmic aqueous solution. (a) Specifications. The drug, which is in an aqueous...

  6. Cobalt separation present in aqueous solution using shell tamarind as bio sorbent

    International Nuclear Information System (INIS)

    Hernandez L, J.

    2014-01-01

    In this work a new carbonaceous material is presented with improved adsorption properties obtained by a heart treatment about 5 min from the shell tamarind. It was found that the samples obtained carbonaceous adsorbents are effective in removing Co 2+ (41 mg / g) ions in aqueous solutions. These samples were prepared from tamarind shell, urea, ammonium nitrate and water. The solution was subjected to a combustion process at different temperatures. Carbonaceous samples prepared in this manner were characterized by X-ray diffraction, infrared spectroscopy, scanning electron microscopy (Sem) and surface area measurements by Physisorption of N 2 . Changes in structure, morphology and texture were studied. The results show that this material is of great importance to the applications of adsorption of metal ions. The measurements of specific surface area (Bet) were 2.35 to 203.76 m 2 g -1 with pore diameters between 2.31 and 15.63 nm, indicating that the samples obtained are predominantly meso porous. The combustion process of the solution proved to be advantageous to improve the textural properties of the tamarind shell. The obtained carbonaceous material plays an important role in adsorption to remove cobalt in aqueous solutions. (Author)

  7. Electrogenerated chemiluminescence induced by sequential hot electron and hole injection into aqueous electrolyte solution

    Energy Technology Data Exchange (ETDEWEB)

    Salminen, Kalle; Kuosmanen, Päivi; Pusa, Matti [Aalto University, Department of Chemistry, Laboratory of Analytical Chemistry, P.O. Box 16100, FI-00076 Aalto (Finland); Kulmala, Oskari [University of Helsinki, Department of Physics, P.O. Box 64, FI-00014 (Finland); Håkansson, Markus [Aalto University, Department of Chemistry, Laboratory of Analytical Chemistry, P.O. Box 16100, FI-00076 Aalto (Finland); Kulmala, Sakari, E-mail: sakari.kulmala@aalto.fi [Aalto University, Department of Chemistry, Laboratory of Analytical Chemistry, P.O. Box 16100, FI-00076 Aalto (Finland)

    2016-03-17

    Hole injection into aqueous electrolyte solution is proposed to occur when oxide-coated aluminum electrode is anodically pulse-polarized by a voltage pulse train containing sufficiently high-voltage anodic pulses. The effects of anodic pulses are studied by using an aromatic Tb(III) chelate as a probe known to produce intensive hot electron-induced electrochemiluminescence (HECL) with plain cathodic pulses and preoxidized electrodes. The presently studied system allows injection of hot electrons and holes successively into aqueous electrolyte solutions and can be utilized in detecting electrochemiluminescent labels in fully aqueous solutions, and actually, the system is suggested to be quite close to a pulse radiolysis system providing hydrated electrons and hydroxyl radicals as the primary radicals in aqueous solution without the problems and hazards of ionizing radiation. The analytical power of the present excitation waveforms are that they allow detection of electrochemiluminescent labels at very low detection limits in bioaffinity assays such as in immunoassays or DNA probe assays. The two important properties of the present waveforms are: (i) they provide in situ oxidation of the electrode surface resulting in the desired oxide film thickness and (ii) they can provide one-electron oxidants for the system by hole injection either via F- and F{sup +}-center band of the oxide or by direct hole injection to valence band of water at highly anodic pulse amplitudes. - Highlights: • Hot electrons injected into aqueous electrolyte solution. • Generation of hydrated electrons. • Hole injection into aqueous electrolyte solution. • Generation of hydroxyl radicals.

  8. Surface micro-dissolve method of imparting self-cleaning property to cotton fabrics in NaOH/urea aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Tao; Hu, Ruimin; Zhao, Zhenyun [College of Textile & Garment, Southwest University, 400716, Chongqing (China); Liu, Yiping [College of Textile & Garment, Southwest University, 400716, Chongqing (China); Chongqing Engineering Research Center of Biomaterial Fiber and Modern Textile, 400716, Chongqing (China); Lu, Ming, E-mail: lumingswu@163.com [College of Textile & Garment, Southwest University, 400716, Chongqing (China); Chongqing Engineering Research Center of Biomaterial Fiber and Modern Textile, 400716, Chongqing (China)

    2017-04-01

    Highlights: • A novel micro-dissolved process was carried out to embedding commercial titanium dioxide nanoparticles into cotton fabric with NaOH/urea aqueous solution. • X-ray diffraction pattern of modified fabrics shown that the cellulose structure of modified fabrics had not changed. • Modified cotton fabrics demonstrated favourable photocatalytic self-cleaning performance while tensile strength and whiteness of treated fabrics also expressed an increasement slightly. - Abstract: A simple and economical micro-dissolved process of embedding titanium dioxide (TiO{sub 2}) nanoparticles into surface zone of cotton fabrics was developed. TiO{sub 2} was coated on cotton fabrics in 7% wt NaOH/12% wt urea aqueous solution at low temperature. Photocatalytic efficiency of cotton fabrics treated with TiO{sub 2} nanoparticles was studied upon measuring the photocatalytic decoloration of Rhodamine B (RhB) under ultraviolet irradiation. Self-cleaning property of cotton fabric coated with TiO{sub 2} was evaluated with color depth of samples (K/S value). The treated fabrics were characterized using scanning electron microscopy (SEM), energy dispersive spectrometer (EDS), Fourier transform infrared spectroscopy (FITR), tensile strength, stiffness and whiteness. The results indicated, TiO{sub 2} nanoparticles could be embedded on the surface layer of cotton fabrics throuth surface micro-dissolve method. Treated cotton fabrics possessed distinct photocatalytic efficiency and self-cleaning properties. Tensile strength and whiteness of modified cotton fabrics appeared moderately increasement.

  9. Sulfonated methyl esters of fatty acids in aqueous solutions: Interfacial and micellar properties.

    Science.gov (United States)

    Danov, Krassimir D; Stanimirova, Rumyana D; Kralchevsky, Peter A; Basheva, Elka S; Ivanova, Veronika I; Petkov, Jordan T

    2015-11-01

    The interest to sulfonated methyl esters of fatty acids (SME) has been growing during the last decade, because these surfactants are considered as an environmentally friendly and renewable alternative of the linear alkyl-benzene sulfonates (LAS). Here, we present a quantitative study on the properties of aqueous SME solutions, and especially on their surface tension isotherms, critical micelle concentration (CMC) and its dependence on the concentration of added NaCl. It is demonstrated that the CMC of an ionic surfactant determined by electrical conductivity is insensitive to the presence of a small nonionic admixture, so that the CMC values determined by conductivity represent the CMC of the pure surfactant. Using SME as an example, we have demonstrated the application of a new and powerful method for determining the physicochemical parameters of the pure ionic surfactant by theoretical data analysis ("computer purification") if the used surfactant sample contains nonionic admixtures, which are present as a rule. This method involves fits of the experimental data for surface tension and conductivity by a physicochemical model based on a system of mass-balance, chemical-equilibrium and electric-double-layer equations, which allows us to determine the adsorption and micellization parameters of C12-, C14-, C16- and C18-SME, as well the fraction of nonionic admixtures (if any). Having determined these parameters, we can further predict the interfacial and micellization properties of the surfactant solutions, such as surface tension, adsorption, degree of counterion binding, and surface electric potential at every surfactant, salt and co-surfactant concentrations. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Effect of temperature and ionic strength on volumetric and acoustic properties of solutions of urea alkyl derivatives in aqueous NaCl

    International Nuclear Information System (INIS)

    Krakowiak, Joanna; Wawer, Jarosław

    2015-01-01

    Highlights: • Urea and its alkyl derivatives in aqueous NaCl solutions were studied. • The density and the speed of sound were measured for presented systems. • The strongest impact of NaCl on obtained quantities is noticed for apparent molar compression. • Bigger hydrophobic character of the solute results in bigger changes of calculated quantities with concentration. • The geometry of the solute is a crucial condition for hydrophobic hydration to happen. - Abstract: The present work was undertaken to study volumetric and acoustic properties for diluted solutions of tetramethylurea in pure water and for urea, n-propylurea, n-butylurea and tetramethylurea in 0.5 or 1 mol · dm −3 aqueous solutions of sodium chloride. This paper presents measured values of densities and sound velocities at T = (288.15, 298.15 and 308.15) K. From these data the apparent molar volumes, V Φ , adiabatic compressibilities, κ S , and apparent molar adiabatic compressions, K S,Φ , were obtained. The values of apparent molar volumes for infinite dilution and limited apparent adiabatic compressions were calculated from extrapolation of the concentration dependence. Further, the corresponding transfer data as well as hydration number of urea and its derivatives in the studied systems were estimated. The obtained parameters are discussed in terms of various solute-solvent and solute-cosolute interactions

  11. Influence of coal properties on mercury uptake from aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Lakatos, J.; Brown, S.D.; Snape, C.E. [Miskolc University, Miskolc-Egyetemvaros (Hungary). Research Inst. of Applied Chemistry

    1999-10-01

    The uptake of mercury (II) from aqueous solution by a range of coals has been studied and the results have been compared to those for a number of other sorbents, including commercial active carbons and cation-exchange resins. At pH 5 in a buffer medium, the capacities for mercury removal of the low-rank coals and the oxidized bituminous coals investigated are comparable to those of the other sorbents tested. For the lignites investigated, a high content of organic sulfur does not markedly affect the capacity for mercury uptake in relatively neutral and low chloride media, owing to redox reactions being the most likely mechanism involved. However, in highly acidic solutions, the capacities for mercury uptake are considerably greater for the high-sulfur coals investigated than for their low-sulfur counterparts due to chelation being the major sorption process involved. 36 refs., 4 figs., 7 tabs.

  12. Aqueous polyethylene oxide solutions

    International Nuclear Information System (INIS)

    Breen, J.

    1987-01-01

    A number of aspects concerning the reorientation of polymer, water and ion hydration complexes have been studied in aqueous solution of polyethylene oxide (PEO). The polymer dynamics are investigated by 1 H-PEO and 13 C-PEO nuclear relaxation experiments. 162 refs.; 30 figs.; 19 tabs

  13. Diffusion coefficients of paracetamol in aqueous solutions

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Barros, Marisa C.F.; Veríssimo, Luís M.P.; Santos, Cecilia I.A.V.; Cabral, Ana M.T.D.P.V.; Gaspar, Gualter D.; Esteso, Miguel A.

    2012-01-01

    Highlights: ► Mutual diffusion coefficients of paracetamol in aqueous dilute solutions. ► Influence of the thermodynamic factors on the variation of their mutual diffusion coefficients. ► Estimation of the mutual limiting diffusion coefficients of the molecular, D m 0 , and ionized forms, D ± 0 , of this drug. - Abstract: Binary mutual diffusion coefficients measured by the Taylor dispersion method, for aqueous solutions of paracetamol (PA) at concentrations from (0.001 to 0.050) mol·dm −3 at T = 298.15 K, are reported. From the Nernst–Hartley equation and our experimental results, the limiting diffusion coefficient of this drug and its thermodynamic factors are estimated, thereby contributing in this way to a better understanding of the structure of such systems and of their thermodynamic behaviour in aqueous solution at different concentrations.

  14. Surface and adsorptive properties of Moringa oleifera bark for removal of V(V) from aqueous solutions.

    Science.gov (United States)

    Mnisi, Robert Londi; Ndibewu, Peter Papoh

    2017-11-04

    The bark of Moringa oleifera, a cheap and readily available natural biopolymeric resource material, found to significantly reduce coliform load and turbidity in contaminated water is investigated in this paper. Its surface and adsorptive properties are investigated to explore its adsorptive potential in removing V(V) from aqueous solutions. Surface properties were investigated using FTIR, HRSEM/EDS, IC, and BET-N 2 adsorption techniques. Adsorptive properties were investigated by optimizing adsorption parameters such as pH, temperature, initial metal concentration, and adsorbent dosage, using V(V) as an adsorbate. The adsorption-desorption isotherms are typical of type II with a H3 hysteresis loop and is characteristic of a largely macroporous material. Bottle ink pores are observed, which can provide good accessibility of the active sites, even though the internal BET surface area is typically low (1.79 g/m 2 ). Solution pH significantly influences the adsorptive potential of the material. The low surface area negatively impacts on the adsorption capacity, but is compensated for by the exchangeable anions (Cl - , F - , PO 4 3- , NO 3 - , and SO 4 2- ) and cations (Ca 2+ , K + , Mg 2+ , and Al 3+ ) at the surface and the accessibility of the active sites. Adsorption isotherm modeling show that the surface is largely heterogeneous with complex multiple sites and adsorption is not limited to monolayer.

  15. Investigating self-assembly and metal nanoclusters in aqueous di-block copolymers solutions

    CERN Document Server

    Lo Celso, F; Triolo, R; Triolo, A; Strunz, P; Bronstein, L; Zwanziger, J; Lin, J S

    2002-01-01

    Self-assembling properties of di-block copolymers/ surfactant hybrids in aqueous solution can be exploited to obtain metal nanoparticles stable dispersion. Results will be presented here for polystyrene-block-poly(ethylene oxide) solutions. A SANS structural investigation has been performed over different molecular weights of both hydrophilic and hydrophobic block, by varying temperature and concentration of the copolymer. A SAXS characterization of micellar systems containing Pt nanoparticles is reported. (orig.)

  16. Hydrogen production by sodium borohydride in NaOH aqueous solution

    Science.gov (United States)

    Wang, Q.; Zhang, L. F.; Zhao, Z. G.

    2018-01-01

    The kinetics of hydrolysis reaction of NaBH4 in NaOH aqueous solution is studied. The influence of pH of the NaOH aqueous solution on the rate of hydrogen production and the hydrogen production efficiency are studied for the hydrolysis reaction of NaBH4. The results show that the activation energy of hydrolysis reaction of NaBH4 increased with the increase of the initial pH of NaOH aqueous solution.With the increasing of the initial pH of NaOH aqueous solution, the rate of hydrogen production and hydrogen production efficiency of NaBH4 hydrolysis decrease.

  17. Knudsen thermogravimetry approach to the thermodynamics of aqueous solutions

    International Nuclear Information System (INIS)

    Schiraldi, Alberto; Signorelli, Marco; Fessas, Dimitrios

    2013-01-01

    Highlights: ► Knudsen cells were designed to replace standard TG pans for desorption experiments. ► The Knudsen effusion data allow determination of water activity of aqueous solutions. ► This methods can replace the traditional isopiestic approach for aqueous solutions. ► The Gibbs–Duhem relationship was used to fit the experimental data. -- Abstract: The use of isothermal TGA with Knudsen-like cells allows determination of the thermodynamic activity of water, a W . The typical experiment implies a slow dehydration of the aqueous solution at constant temperature in dynamic vacuum conditions. The method is alternative to the classical isopiestic approach and offers the advantage of a continuous record on increasing the solute concentration. These data can be directly treated according to the classical thermodynamic relationships drawn from the Gibbs–Duhem expression to evaluate the activity and osmotic coefficient of the aqueous solutions of electrolytes and non-electrolytes, and, in the case of electrolytes, allow determination of solubility of the solute. Discrepancies with respect to the literature data are observed when the viscosity of the systems becomes too high, as in the case of sugars with a very large solubility. Such a mismatch may however be accounted for either slowing the dehydration rate with use of a narrower Knudsen orifice, or correcting the experimental a W with a calibration curve. The same approach can be applied to non-aqueous solutions

  18. Volumetric, ultrasonic and viscometric studies of solute–solute and solute–solvent interactions of l-threonine in aqueous-sucrose solutions at different temperatures

    International Nuclear Information System (INIS)

    Nain, Anil Kumar; Pal, Renu; Neetu

    2013-01-01

    Highlights: • The study reports density, ultrasonic speed and viscosity data of l-threonine in aqueous-sucrose solutions. • The study elucidates interactions of l-threonine with sucrose in aqueous media. • Provides data to estimate physicochemical properties of proteins in these media. • Correlates physicochemical properties of l-threonine with its behaviour in aqueous-sucrose solutions. -- Abstract: Densities, ρ of solutions of l-threonine in aqueous-sucrose solvents 5%, 10%, 15%, and 20% of sucrose, w/w in water at T = (293.15, 298.15, 303.15, 308.15, 313.15, and 318.15) K; and ultrasonic speeds, u and viscosities, η of these solutions at 298.15, 303.15, 308.15, 313.15, and 318.15 K were measured at atmospheric pressure. From these experimental results, the apparent molar volume, V ϕ , limiting apparent molar volume, V ϕ ∘ and the slope, S v , apparent molar compressibility, K s,ϕ , limiting apparent molar compressibility, K s,ϕ ∘ and the slope, S k , transfer volume, V ϕ,tr ∘ , transfer compressibility, K s,ϕ,tr ∘ , limiting apparent molar expansivity, E ϕ ∘ , Hepler’s constant, (∂ 2 V ϕ ∘ /dT 2 ), Falkenhagen coefficient, A, Jones–Dole coefficient, B and hydration number, n H have been calculated. The results have been interpreted in terms of solute–solvent and solute–solute interactions in these systems. The Gibbs energies of activation of viscous flow per mole of solvent, Δμ 1 ∘number sign and per mole of solute, Δμ 2 ∘number sign were also calculated and discussed in terms of transition state theory. It has been observed that there exist strong solute–solvent interactions in these systems and these interactions increase with increase in sucrose concentration in solution

  19. The characterization methods for colloids in aqueous solutions

    International Nuclear Information System (INIS)

    Vuorinen, U.; Kumpulainen, H.

    1993-11-01

    This literature review deals with characterization methods for colloids in aqueous solutions and in groundwater. The basis for the review has been the needs of nuclear waste disposal studies and methods applicable in such studies. The methods considered include non-destructive laserspectroscopic methods (e.g. TRLFS, LPAS, PALS), several separation methods (e.g. ultrafiltration, dialysis, electrophoresis, field-flow-fractionation) and also some surface analytical methods, as well as some other methods giving additional information on formation and migration properties of colloids. (au.) (71 refs., 13 figs., 3 tabs.)

  20. Photoluminescence of hydrophilic silicon nanocrystals in aqueous solutions

    International Nuclear Information System (INIS)

    Prtljaga, Nikola; D'Amato, Elvira; Pitanti, Alessandro; Guider, Romain; Froner, Elena; Larcheri, Silvia; Scarpa, Marina; Pavesi, Lorenzo

    2011-01-01

    Stable aqueous solutions of undecylenic-acid-grafted silicon nanocrystals (Si-nc) were prepared. The time evolution of the photoluminescence properties of these hydrophilic silicon nanocrystals has been followed on different timescales (hours and days). On a short timescale (hours), Si-nc tend to agglomerate while the PL lineshape and intensity are stable. Agglomeration can be reduced by using suitable surfactants. On a long timescale (days), oxidation of Si-nc occurs even in the presence of surfactants. These two observations render Si-nc very useful as a labeling agent for biosensing.

  1. Photoluminescence of hydrophilic silicon nanocrystals in aqueous solutions

    Science.gov (United States)

    Prtljaga, Nikola; D'Amato, Elvira; Pitanti, Alessandro; Guider, Romain; Froner, Elena; Larcheri, Silvia; Scarpa, Marina; Pavesi, Lorenzo

    2011-05-01

    Stable aqueous solutions of undecylenic-acid-grafted silicon nanocrystals (Si-nc) were prepared. The time evolution of the photoluminescence properties of these hydrophilic silicon nanocrystals has been followed on different timescales (hours and days). On a short timescale (hours), Si-nc tend to agglomerate while the PL lineshape and intensity are stable. Agglomeration can be reduced by using suitable surfactants. On a long timescale (days), oxidation of Si-nc occurs even in the presence of surfactants. These two observations render Si-nc very useful as a labeling agent for biosensing.

  2. Photoluminescence of hydrophilic silicon nanocrystals in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Prtljaga, Nikola; D' Amato, Elvira; Pitanti, Alessandro; Guider, Romain; Froner, Elena; Larcheri, Silvia; Scarpa, Marina; Pavesi, Lorenzo, E-mail: nikolap@science.unitn.it [Department of Physics, University of Trento, Via Sommarive 14, I-38123 Trento (Italy)

    2011-05-27

    Stable aqueous solutions of undecylenic-acid-grafted silicon nanocrystals (Si-nc) were prepared. The time evolution of the photoluminescence properties of these hydrophilic silicon nanocrystals has been followed on different timescales (hours and days). On a short timescale (hours), Si-nc tend to agglomerate while the PL lineshape and intensity are stable. Agglomeration can be reduced by using suitable surfactants. On a long timescale (days), oxidation of Si-nc occurs even in the presence of surfactants. These two observations render Si-nc very useful as a labeling agent for biosensing.

  3. Polymers for enhanced oil recovery : A paradigm for structure-property relationship in aqueous solution

    NARCIS (Netherlands)

    Wever, D. A. Z.; Picchioni, F.; Broekhuis, A. A.

    Recent developments in the field of water-soluble polymers aimed at enhancing the aqueous solution viscosity are reviewed. Classic and novel associating water-soluble polymers for enhanced oil recovery (EOR) applications are discussed along with their limitations. Particular emphasis is placed on

  4. Dielectric dispersion, relaxation dynamics and thermodynamic studies of Beta-Alanine in aqueous solutions using picoseconds time domain reflectometry

    Science.gov (United States)

    Vinoth, K.; Ganesh, T.; Senthilkumar, P.; Sylvester, M. Maria; Karunakaran, D. J. S. Anand; Hudge, Praveen; Kumbharkhane, A. C.

    2017-09-01

    The aqueous solution of beta-alanine characterised and studied by their dispersive dielectric properties and relaxation process in the frequency domain of 10×106 Hz to 30×109 Hz with varying concentration in mole fractions and temperatures. The molecular interaction and dielectric parameters are discussed in terms of counter-ion concentration theory. The static permittivity (ε0), high frequency dielectric permittivity (ε∞) and excess dielectric parameters are accomplished by frequency depended physical properties and relaxation time (τ). Molecular orientation, ordering and correlation factors are reported as confirmation of intermolecular interactions. Ionic conductivity and thermo dynamical properties are concluded with the behaviour of the mixture constituents. Solute-solvent, solute-solute interaction, structure making and breaking abilities of the solute in aqueous medium are interpreted. Fourier Transform Infrared (FTIR) spectra of beta- alanine single crystal and liquid state have been studied. The 13C Nuclear Magnetic Resonance (NMR) spectral studies give the signature for resonating frequencies and chemical shifts of beta-alanine.

  5. Radiolysis of aqueous solutions of insulin. [. gamma. rays

    Energy Technology Data Exchange (ETDEWEB)

    Foitik, A [Ceskoslovenska Akademie Ved, Prague. Ustav Fyzikalni Chemie a Elektrochemie J. Heyrovskeho; Kopoldova, J [Ceskoslovenska Akademie Ved, Prague. Isotopova Laborator Biologickych Ustavu

    1976-08-01

    The effect of ionizing radiation on diluted aqueous solutions of insulin is analyzed. The rate of decrease in its level (the loss of polarographic activity) is described by a first-order kinetic equation. The results lead to the concept of a direct effect on macromolecules in 'excited volumes'. The amount of inactivated molecules (i.e., the yield) in this volume is proportional to the solute concentration. In diluted aqueous solutions indirect radiation effects also take place. The paper evaluates these effects.

  6. Assorted interactions of amino acids prevailing in aqueous vitamin C solutions probed by physicochemical and ab-initio contrivances

    Science.gov (United States)

    Das, Koyeli; Roy, Milan Chandra; Rajbanshi, Biplab; Roy, Mahendra Nath

    2017-11-01

    Qualitative and quantitative analysis of molecular interaction prevailing in tyrosine and tryptophan in aqueous solution of vitamin C have been probed by thermophysical properties. The apparent molar volume (ϕV), viscosity B-coefficient, molal refraction (RM) of tyrosine and tryptophan have been studied in aqueous vitamin C solutions at diverse temperatures via Masson equation which deduced solute-solvent and solute-solute interactions, respectively. Spectroscopic study along with physicochemical and computational techniques provides lots of interesting and highly significant insights of the model biological systems. The overall results established strong solute-solvent interactions between studied amino acids and vitamin C mixture in the ternary solutions.

  7. Conductivity and electrochemical stability of concentrated aqueous choline chloride solutions

    Science.gov (United States)

    Grishina, E. P.; Kudryakova, N. O.

    2017-10-01

    The conductivity and electrochemical stability of choline chloride (ChCl) solutions with water contents ranging from 20 to 39 wt % are studied. Exposing ChCl to moist ambient air yields a highly concentrated aqueous solution that, as an electrolyte, exhibits the properties and variations in conductivity with temperature and concentration characteristic of other similar systems. Its electrochemical stability window, determined by cyclic voltammetry, is comparable to that of ChCl-based deep eutectic solvents (DESs). Products of the electrolysis of ChCl‒H2O mixtures seem to be less toxic than those of Reline, Ethaline, and Maline.

  8. Enthalpy of dilution and volumetric properties of N-glycylglycine in aqueous xylitol solutions at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Liu Min, E-mail: panpanliumin@163.co [College of Chemistry and Chemical Engineering, Liao Cheng University, Liaocheng, Shandong 252059 (China); Wang Lili; Li Guangqian; Dong Lina; Sun Dezhi [College of Chemistry and Chemical Engineering, Liao Cheng University, Liaocheng, Shandong 252059 (China); Zhu Lanying [College of Life Science and Bioengineering, Liao Cheng University, Liaocheng, Shandong 252059 (China); Di Youying [College of Chemistry and Chemical Engineering, Liao Cheng University, Liaocheng, Shandong 252059 (China)

    2011-06-15

    Highlights: Enthalpies of dilution of N-glycylglycine in aqueous xylitol solutions were determined at 298.15 K. The homogeneous enthalpic interaction coefficients were calculated. Apparent molar volumes of the ternary systems were calculated from the data of densities. Limiting partial molar volumes and limiting partial molar volumes of transfer were deduced. - Abstract: The enthalpy of dilution of N-glycylglycine ({Delta}{sub dil}H{sub m}) in aqueous xylitol solutions has been determined by means of flow-mix isothermal microcalorimetry at the temperature of 298.15 K. The homogeneous enthalpic interaction coefficients (h{sub 2}, h{sub 3}, and h{sub 4}) which characterize the interactions of examined N-glycylglycine in aqueous xylitol solutions have been calculated according to the excess enthalpy concept based on the values of dilution enthalpy. It has been found that the enthalpic pair interaction coefficients (h{sub 2}) in the systems investigated are negative and become less negative as the molality of xylitol increases. Values of the density ({rho}) of the ternary homogeneous systems were also measured with a quartz vibrating-tube densimeter at the temperature of 298.15 K. The values of the apparent molar volume (V{sub {phi}}) of the ternary systems were calculated from the data of density, which have been used to deduce limiting partial molar volumes of N-glycylglycine (V{sub {phi}}{sup o}) and limiting partial molar volumes of transfer ({Delta}{sub trs}V{sub {phi}}{sup o}) from water to aqueous xylitol solutions at different concentrations. The results have been discussed based on solute-solute interactions and solvation effects.

  9. Enthalpy of dilution and volumetric properties of N-glycylglycine in aqueous xylitol solutions at T = 298.15 K

    International Nuclear Information System (INIS)

    Liu Min; Wang Lili; Li Guangqian; Dong Lina; Sun Dezhi; Zhu Lanying; Di Youying

    2011-01-01

    Highlights: → Enthalpies of dilution of N-glycylglycine in aqueous xylitol solutions were determined at 298.15 K. → The homogeneous enthalpic interaction coefficients were calculated. → Apparent molar volumes of the ternary systems were calculated from the data of densities. → Limiting partial molar volumes and limiting partial molar volumes of transfer were deduced. - Abstract: The enthalpy of dilution of N-glycylglycine (Δ dil H m ) in aqueous xylitol solutions has been determined by means of flow-mix isothermal microcalorimetry at the temperature of 298.15 K. The homogeneous enthalpic interaction coefficients (h 2 , h 3 , and h 4 ) which characterize the interactions of examined N-glycylglycine in aqueous xylitol solutions have been calculated according to the excess enthalpy concept based on the values of dilution enthalpy. It has been found that the enthalpic pair interaction coefficients (h 2 ) in the systems investigated are negative and become less negative as the molality of xylitol increases. Values of the density (ρ) of the ternary homogeneous systems were also measured with a quartz vibrating-tube densimeter at the temperature of 298.15 K. The values of the apparent molar volume (V φ ) of the ternary systems were calculated from the data of density, which have been used to deduce limiting partial molar volumes of N-glycylglycine (V φ o ) and limiting partial molar volumes of transfer (Δ trs V φ o ) from water to aqueous xylitol solutions at different concentrations. The results have been discussed based on solute-solute interactions and solvation effects.

  10. Pulse electrodeposition of Pt and Pt–Ru methanol-oxidation nanocatalysts onto carbon nanotubes in citric acid aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Huei-Yu [Department of Engineering and System Science, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC (China); Hsieh, Chien-Kuo [Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan, ROC (China); Tsai, Ming-Chi; Wei, Yu-Hsuan; Yeh, Tsung-Kuang [Department of Engineering and System Science, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC (China); Tsai, Chuen-Horng, E-mail: tsai@aec.gov.tw [Department of Engineering and System Science, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC (China)

    2015-06-01

    In this study, platinum nanoparticle/carbon nanotube (Pt NP/CNT) and platinum–ruthenium nanoparticle (Pt–Ru NP/CNT) hybrid nanocatalysts were prepared by the pulse-electrodeposition method in different aqueous solutions containing citric acid (CA) or sulfuric acid (SA). The electrocatalytic properties of the Pt NP/CNT and Pt–Ru NP/CNT electrodes prepared using different aqueous solutions were investigated for methanol oxidation. The results show that the electrochemical mass activities of these hybrid nanocatalysts prepared in the CA aqueous solution were increased by factors of 1.46 and 2.77 for Pt NPs and Pt–Ru NPs, respectively, compared with those prepared in SA aqueous solutions using the same procedure. These increased mass activities are attributed to the CA playing dual roles as both a stabilizing agent and a particle size reducing agent in the aqueous solutions. The approach developed in this work enables further reductions in the particle sizes of noble-metal nanocatalysts. - Highlights: • Pulse-electrodeposition of Pt or Pt–Ru nanoparticles on carbon nanotubes • Carbon nanotubes used as a catalyst-supporting material • Citric acid used as reducing agent in the aqueous electrodeposition solutions • Electrochemical activity for methanol oxidation improved by a factor of 1.46 to 2.77.

  11. Adsorption and recovery of lead(II) from aqueous solutions by immobilized Pseudomonas Aeruginosa PU21 beads

    International Nuclear Information System (INIS)

    Lin, C.-C.; Lai, Y.-T.

    2006-01-01

    In this study, immobilized Pseudomonas aeruginosa PU21 beads were used as an adsorbent for lead(II). Different weight percentages of chitosan were added to polyethylene glycol (PEG, 0.5 wt.% in aqueous solution) and alginate (18 wt.% in aqueous solution), and then blended or cross-linked using different concentrations of epichlorohydrin (ECH) to prepare beads of different sizes and increased mechanical strength. Before blending or cross-linking, different weight percentages of P. aeruginosa PU21 were added to increase lead(II) adsorption. Subsequently the optimized bead composition (concentration of ECH, percentages of chitosan and P. aeruginosa PU21) and the optimum adsorption conditions (agitation rate and pH in the aqueous solution) were ascertained. Finally, the optimized beads adsorbing lead(II) were regenerated by 0.1 M aqueous HCl solutions and the most effective desorption agitation rate was ascertained. The results indicate that the reuse of immobilized P. aeruginosa PU21 beads was feasible. In addition, the equilibrium adsorption, kinetics, changes in the thermodynamic properties of adsorption of lead(II) on optimized beads were also investigated

  12. Uranium (VI) complexing by macrocyclic or chelating ligands in aqueous solutions stability, formation kinetics, polarographic properties

    International Nuclear Information System (INIS)

    Brighli, M.

    1984-07-01

    Stability of chelates (with EDTA,N,N ethylenediamine diacetic acid EDDA nitrilotriacetic acid NTA and iminodiacetic acid) of UO 2 2+ and UO 4 species of uranium VI is studied in aqueous solution (NaClO 4 3M at 25 deg celcius). Structure in solution are proposed and discussed for mononuclear species. Only complexing kinetics (formation and acid hydrolysis) of UO 4 with EDDA and NTA are studied by spectrophotometry (other reactions are too fast). Besides UO 2 2+ complexes are formed with crown ethers I5C5 and I8C6 in aqueous solution (TEA ClO 4 M/10 at 25 deg celcius. Complexes are probably stabilized by solvation. Results are confirmed by voltametry and reduction mechanisms of UO 2 2+ and its complexes on mercury drop are proposed. 143 refs [fr

  13. Synthesis of 1,3-Dimethylimidazolium Chloride and Volumetric Property Investigations of Its Aqueous Solution

    Science.gov (United States)

    Dong, L.; Zheng, D. X.; Wei, Z.; Wu, X. H.

    2009-10-01

    By investigating the vapor pressure of the solvent and the affinity between ionic liquids (ILs) and the solvent, it is proposed that 1,3-dimethylimidazolium chloride ([Mmim]Cl) has the potential to be used as a novel absorbent species with the absorption cycle working fluid. Adopting a high-pressure reaction kettle, the method of gas-liquid phase reaction was used to synthesize [Mmim]Cl under the conditions of 348.15 K and 0.7 MPa. The densities of [Mmim]Cl aqueous solutions were measured for mass fractions in the range from 20% to 90% at 293.15 K, 298.15 K, 303.15 K, 308.15 K, 313.15 K, and 318.15 K with a digital vibrating-tube densimeter. The excess volume, the apparent molar volume, the partial molar volume, and the apparent molar expansibility of this system were investigated, and the influences of variations of the cation and anion on the density of several IL aqueous solutions are discussed.

  14. Acetic acid extraction from aqueous solutions using fatty acids

    NARCIS (Netherlands)

    IJmker, H.M.; Gramblicka, M.; Kersten, Sascha R.A.; van der Ham, Aloysius G.J.; Schuur, Boelo

    2014-01-01

    A major challenge for production of acetic acid via bio-based routes is cost-effective concentration and purification of the acetic acid from the aqueous solutions, for which liquid–liquid extraction is a possible method. A main challenge in extraction of acetic acid from dilute aqueous solutions is

  15. Apparent molal volumes of HMT and TATD in aqueous solutions around the temperature of maximum density of water

    International Nuclear Information System (INIS)

    Clavijo Penagos, J.A.; Blanco, L.H.

    2012-01-01

    Highlights: ►V φ for HMT and TATD in aqueous solutions around the temperature of maximum density of water are reported. ► V φ is linear in m form m = 0.025 for all the aqueous solutions investigated. ► Variation of V ¯ 2 ∞ with T obeys a second grade polynomial trend. ► The solutes are classified as structure breakers according to Hepler’s criterion. - Abstract: Apparent molal volumes V φ have been determined from density measurements for several aqueous solutions of 1,3,5,7-tetraazatricyclo[3.3.1.1(3,7)]decane (HMT) and 1,3,6,8-tetraazatricyclo[4.4.1.1(3,8)]dodecane (TATD) at T = (275.15, 275.65, 276.15, 276.65, 277.15, 277.65 and 278.15) K as function of composition. The infinite dilution partial molar volumes of solutes in aqueous solution are evaluated through extrapolation. Interactions of the solutes with water are discussed in terms of the effect of the temperature on the volumetric properties and the structure of the solutes. The results are interpreted in terms of water structure-breaking or structure forming character of the solutes.

  16. Photolysis of Periodate and Periodic Acid in Aqueous Solution

    DEFF Research Database (Denmark)

    Sehested, Knud; Kläning, U. K.

    1978-01-01

    The photochemistry of periodate and periodic acid in aqueous solution was studied (i) by quantum yield measurements at low light intensity (ii) by flash photolysis, and (iii) by photolysis of glassy samples at 77 K. The photochemical studies were supplemented with pulse radiolysis studies...... of aqueous periodate solutions and with kinetic studies using stopped-flow technique. In strongly alkaline solution the photodecomposition of periodate proceeds via formation of O– and IVI. At pH solution O3 P is formed in a small...

  17. Chemistry in high temperature aqueous solutions application to the power industry

    International Nuclear Information System (INIS)

    Cohen, P.

    1990-01-01

    The power industry utilizes water (aqueous solutions) for two main functions: as a medium for heat transfer and transport and as a thermodynamic working fluid. These functions are performed in systems fabricated from a wide variety of materials, over a wide range of thermal and hydraulic conditions, and at medium temperatures and densities which determine the significant chemical properties. The major chemical interest is in the concentrated solutions derived from the dilute working fluid at selected sites defined by the physical arrangement and temperature and in their consequential effects on heat transfer and corrosion. Examples of these sites for typical fossil fired and nuclear steam generating equipment are described, as well as the extent and limit of the concentration process. The history of steam power plant water chemistry is discussed from the point of view of the chemical processes involved. The period covered is from the 1920s to the present state of the art, which is a major application of the subject of this symposium--chemistry in high temperature aqueous solution

  18. Measurements of thermodynamic and optical properties of selected aqueous organic and organic-inorganic mixtures of atmospheric relevance.

    Science.gov (United States)

    Lienhard, Daniel M; Bones, David L; Zuend, Andreas; Krieger, Ulrich K; Reid, Jonathan P; Peter, Thomas

    2012-10-11

    Atmospheric aerosol particles can exhibit liquid solution concentrations supersaturated with respect to the dissolved organic and inorganic species and supercooled with respect to ice. In this study, thermodynamic and optical properties of sub- and supersaturated aqueous solutions of atmospheric interest are presented. The density, refractive index, water activity, ice melting temperatures, and homogeneous ice freezing temperatures of binary aqueous solutions containing L(+)-tartaric acid, tannic acid, and levoglucosan and ternary aqueous solutions containing levoglucosan and one of the salts NH(4)HSO(4), (NH(4))(2)SO(4), and NH(4)NO(3) have been measured in the supersaturated concentration range for the first time. In addition, the density and refractive index of binary aqueous citric acid and raffinose solutions and the glass transition temperatures of binary aqueous L(+)-tartaric acid and levoglucosan solutions have been measured. The data presented here are derived from experiments on single levitated microdroplets and bulk solutions and should find application in thermodynamic and atmospheric aerosol models as well as in food science applications.

  19. Effect of temperature on solvation behaviour of diclofenac sodium salt in aqueous glycine and L-proline solutions

    International Nuclear Information System (INIS)

    Ryshetti, Suresh; Gardas, Ramesh L; Tangeda, Savitha Jyostna

    2015-01-01

    Highlights: • Solvation behaviour of diclofenac drug studied in aqueous solutions. • Density and speed of sound of drug in aq. glycine and L-proline are measured. • Hydrophobic nature of diclofenac sodium salt is studied. • Effect of temperature on solvation of diclofenac sodium salt is analysed. - Abstract: Apparent molar volume (V 2,ϕ ) and apparent molar isentropic compressibility (K s,2,ϕ ) of diclofenac sodium salt (DSS) drug within the concentration range of (0.001 to 0.008) mol · kg −1 in (0.01, 0.03 and 0.05) mol · kg −1 aqueous glycine and L-proline solutions are computed from the experimental density (ρ) and speed of sound (u) values at T = (293.15 to 313.15) K and atmospheric pressure. Derived parameters such as partial molar properties, transfer partial molar properties, hydration numbers and Hepler’s constant are computed from the data of V 2,ϕ and K s,2,ϕ . These parameters have been used to understand the effect of temperature on interactions between DSS drug and aqueous glycine/L-proline solution. Furthermore, the structure making and breaking ability of DSS drug in probed solutions are analysed at experimental conditions

  20. Method of precipitating uranium from an aqueous solution and/or sediment

    Science.gov (United States)

    Tokunaga, Tetsu K; Kim, Yongman; Wan, Jiamin

    2013-08-20

    A method for precipitating uranium from an aqueous solution and/or sediment comprising uranium and/or vanadium is presented. The method includes precipitating uranium as a uranyl vanadate through mixing an aqueous solution and/or sediment comprising uranium and/or vanadium and a solution comprising a monovalent or divalent cation to form the corresponding cation uranyl vanadate precipitate. The method also provides a pathway for extraction of uranium and vanadium from an aqueous solution and/or sediment.

  1. Physical chemistry of the interface between oxide and aqueous solution

    International Nuclear Information System (INIS)

    Jolivet, J.P.

    1997-01-01

    The behavior and properties of small oxide particles in aqueous suspension are dominated by the physico-chemistry of their surface. It is electrostatically charged and strongly solvated. The origin of the surface charge is discussed through the MUSIC model [Hiemstra 1996], allowing to estimate the acid-base behavior of surface oxygen atoms. The stability of aqueous dispersions of particles is analysed following the DLVO model, with a special attention on the hydration layers allowing the peptization of flocs. Different adsorption mechanisms of metal cations are presented in terms of coordination chemistry (outer- and inner-sphere complexes) emphasizing the coordinating ability of the surface towards metal complexes in solution. The anion adsorption is also studied in relation with some interesting consequences on spinel iron oxide nano-particles. (author)

  2. Study of free acidity determinations in aqueous solution

    International Nuclear Information System (INIS)

    Kergreis, A.

    1966-04-01

    The object of this work is the study of the principal methods which can be applied to the measurement of 'free' acidity. In the first part, we define the various types of acidity which can exist in aqueous solution; then, after having studied some hydrolysis reactions, we compare the value of the neutralisation pH of the hydrated cation and that of the precipitation of the hydroxide. In the second part we have started to study the determination of the acidity of an aqueous solution. After having rapidly considered the 'total' acidity determination, we deal with the problem of the 'free' acidity titration. We have considered in particular certain methods: extrapolation of the equivalent point, colorimetric titrations with or without a complexing agent, and finally the use of ion-exchange resins with mixed aqueous and solvent solutions. (author) [fr

  3. Study on the acid-base surface property of the magnetite graphene oxide and its usage for the removal of radiostrontium from aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H.; Li, J.X.; Zhang, S.W.; Ren, X.M.; Sun, Y.B.; Wen, T.; Wang, X.K. [Chinese Academy of Sciences, Hefei (China). Key Laboratory of Novel Thin Film Solar Cells

    2013-07-01

    Acid-base titrations of magnetite/graphene oxide (M/GO) and Sr(II) adsorption onto M/GO were operated to investigate surface properties of M/GO and surface complexation bonding interactions between Sr(II) and M/GO. Experimental results showed that Sr(II) adsorption onto M/GO was facilitated by a high pH value and a low ionic strength. Modeling results exhaustively explained the changes of adsorption morphological at different pH and ionic strengths. Thermodynamic parameters ({Delta}H , {Delta}S , and {Delta}G ) calculated from the adsorption isotherms showed the adsorption of Sr(II) onto M/GO composite was an endothermic and spontaneous process. M/GO could be separated by magnetic separation from aqueous solution in large scale. The adsorption performance suggests M/GO could be a promising adsorbent material for the preconcentration and separation of radiostrontium from aqueous solution in radionuclide pollution cleanup. (orig.)

  4. Principles of interactions in non-aqueous electrolyte solutions

    NARCIS (Netherlands)

    Lyklema, J.

    2013-01-01

    In this paper a review is presented on the molecular interactions in non-aqueous media of low dielectric permittivity. Qualitative and quantitative distinctions with aqueous solutions are emphasized. The reviewed themes include dispersion forces, dissociation and association equilibria,

  5. Arsenic (III Adsorption Using Palladium Nanoparticles from Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Farzaneh Arsiya

    2017-07-01

    Full Text Available The presence of Arsenic in drinking water is the greatest threat to health effects especially in water. The purpose of this study is application of green palladium nanoparticles for removal of trivalent Arsenic from aqueous solutions and also the impact of some factors such as retention time, pH, concentration of palladium nanoparticles and Arsenic concentrations was studied. The values for Arsenic removal from aqueous solutions were measured by furnace atomic adsorption spectrometry (Conter AA700. In the study, Langmuir and Freundlich isotherm models and pseudo-second order kinetic model were studied. The results of  optimization is shown that 0.5 g of nanoparticles can removed %99.8 of Arsenic with initial concentration of  0.5 g/l, in 5 minutes at pH=4. Langmuir model, Freundlich model (R2=0.94 and pseudo-second order kinetic model (R2=0.99 shown high correlation for removing of Arsenic from aqueous solutions. It was found, palladium nanoparticles can be used as an efficient method to remove Arsenic from aqueous solutions in a short time.

  6. Electronic-property dependent interactions between tetracycline and graphene nanomaterials in aqueous solution.

    Science.gov (United States)

    He, Lin; Liu, Fei-Fei; Zhao, Mengyao; Qi, Zhen; Sun, Xuefei; Afzal, Muhammad Zaheer; Sun, Xiaomin; Li, Yanhui; Hao, Jingcheng; Wang, Shuguang

    2018-04-01

    Understanding the interactions between graphene nanomaterials (GNMs) and antibiotics in aqueous solution is critical to both the engineering applications of GNMs and the assessment of their potential impact on the fate and transport of antibiotics in the aquatic environment. In this study, adsorption of one common antibiotic, tetracycline, by graphene oxide (GO) and reduced graphene oxide (RGO) was examined with multi-walled carbon nanotubes (MWCNTs) and graphite as comparison. The results showed that the tetracycline adsorption capacity by the four selected carbonaceous materials on the unit mass basis followed an order of GO>RGO>MWCNTs>graphite. Upon normalization by surface area, graphite, RGO and MWCNTs had almost the same high tetracycline adsorption affinity while GO exhibited the lowest. We proposed π-electron-property dependent interaction mechanisms to explain the observed different adsorption behaviors. Density functional theory (DFT) calculations suggested that the oxygen-containing functional groups on GO surface reduced its π-electron-donating ability, and thus decreased the π-based interactions between tetracycline and GO surface. Comparison of adsorption efficiency at different pH indicated that electrostatic interaction also played an important role in tetracycline-GO interactions. Site energy analysis confirmed a highly heterogeneous distribution of the binding sites and strong tetracycline binding affinity of GO surface. Copyright © 2017. Published by Elsevier B.V.

  7. Ultrafast dynamics of hydrogen bond exchange in aqueous ionic solutions.

    Science.gov (United States)

    Park, Sungnam; Odelius, Michael; Gaffney, Kelly J

    2009-06-04

    The structural and dynamical properties of aqueous ionic solutions influence a wide range of natural and biological processes. In these solutions, water has the opportunity to form hydrogen bonds with other water molecules and anions. Knowing the time scale with which these configurations interconvert represents a key factor to understanding the influence of molecular scale heterogeneity on chemical events in aqueous ionic solutions. We have used ultrafast IR spectroscopy and Car-Parrinello molecular dynamics (CPMD) simulations to investigate the hydrogen bond (H-bond) structural dynamics in aqueous 6 M sodium perchlorate (NaClO4) solution. We have measured the H-bond exchange dynamics between spectrally distinct water-water and water-anion H-bond configurations with 2DIR spectroscopy and the orientational relaxation dynamics of water molecules in different H-bond configurations with polarization-selective IR pump-probe experiments. The experimental H-bond exchange time correlates strongly with the experimental orientational relaxation time of water molecules. This agrees with prior observations in water and aqueous halide solutions, and has been interpreted within the context of an orientational jump model for the H-bond exchange. The CPMD simulations performed on aqueous 6 M NaClO4 solution clearly demonstrate that water molecules organize into two radially and angularly distinct structural subshells within the first solvation shell of the perchlorate anion, with one subshell possessing the majority of the water molecules that donate H-bonds to perchlorate anions and the other subshell possessing predominantly water molecules that donate two H-bonds to other water molecules. Due to the high ionic concentration used in the simulations, essentially all water molecules reside in the first ionic solvation shells. The CPMD simulations also demonstrate that the molecular exchange between these two structurally distinct subshells proceeds more slowly than the H

  8. Three strategies to stabilise nearly monodispersed silver nanoparticles in aqueous solution

    Science.gov (United States)

    Stevenson, Amadeus PZ; Blanco Bea, Duani; Civit, Sergi; Antoranz Contera, Sonia; Iglesias Cerveto, Alberto; Trigueros, Sonia

    2012-02-01

    Silver nanoparticles are extensively used due to their chemical and physical properties and promising applications in areas such as medicine and electronics. Controlled synthesis of silver nanoparticles remains a major challenge due to the difficulty in producing long-term stable particles of the same size and shape in aqueous solution. To address this problem, we examine three strategies to stabilise aqueous solutions of 15 nm citrate-reduced silver nanoparticles using organic polymeric capping, bimetallic core-shell and bimetallic alloying. Our results show that these strategies drastically improve nanoparticle stability by distinct mechanisms. Additionally, we report a new role of polymer functionalisation in preventing further uncontrolled nanoparticle growth. For bimetallic nanoparticles, we attribute the presence of a higher valence metal on the surface of the nanoparticle as one of the key factors for improving their long-term stability. Stable silver-based nanoparticles, free of organic solvents, will have great potential for accelerating further environmental and nanotoxicity studies. PACS: 81.07.-b; 81.16.Be; 82.70.Dd.

  9. Removal of patulin from aqueous solutions by propylthiol functionalized SBA-15

    Energy Technology Data Exchange (ETDEWEB)

    Appell, Michael, E-mail: michael.appell@ars.usda.gov [Bacterial Foodborne Pathogens and Mycology Research Unit, United States Department of Agriculture, Agricultural Research Service, National Center for Agricultural Utilization Research, 1815 N. University St., Peoria, IL 61604 (United States); Jackson, Michael A.; Dombrink-Kurtzman, Mary Ann [Renewable Product Technology Research Unit, United States Department of Agriculture, Agricultural Research Service, National Center for Agricultural Utilization Research, 1815 N. University St., Peoria, IL 61604 (United States)

    2011-03-15

    Propylthiol functionalized SBA-15 silica was investigated to detoxify aqueous solutions contaminated with the regulated mycotoxin patulin. Micelle templated silicas with a specific pore size were synthetically modified to possess propylthiol groups, a functional group known to form Michael reaction products with the conjugated double bond system of patulin. BET surface area analysis indicated the propylthiol functionalized SBA-15 possesses channels with the pore size of 5.4 nm and a surface area of 345 m{sup 2} g{sup -1}. Elemental analysis indicates the silicon/sulfur ratio to be 10:1, inferring one propylthiol substituent for every ten silica residues. The propylthiol modified SBA-15 was effective at significantly reducing high levels of patulin from aqueous solutions (pH 7.0) in batch sorption assays at room temperature. The material was less effective at lower pH; however heating low pH solutions and apple juice to 60 deg, C in the presence of propylthiol functionalized SBA-15 significantly reduced the levels of patulin in contaminated samples. Composite molecular models developed by semi-empirical PM3 and empirical force field methods support patulin permeation through the mesoporous channels of propylthiol functionalized SBA-15. Density functional study at the B3LYP/6-31G(d,p) level predicts the proposed patulin adducts formed by reaction with the thiol residues exhibit less electrophilic properties than patulin. It is demonstrated the use of propylthiol functionalized SBA-15 is a viable approach to reduce patulin levels in aqueous solutions, including contaminated apple juice.

  10. Removal of patulin from aqueous solutions by propylthiol functionalized SBA-15

    International Nuclear Information System (INIS)

    Appell, Michael; Jackson, Michael A.; Dombrink-Kurtzman, Mary Ann

    2011-01-01

    Propylthiol functionalized SBA-15 silica was investigated to detoxify aqueous solutions contaminated with the regulated mycotoxin patulin. Micelle templated silicas with a specific pore size were synthetically modified to possess propylthiol groups, a functional group known to form Michael reaction products with the conjugated double bond system of patulin. BET surface area analysis indicated the propylthiol functionalized SBA-15 possesses channels with the pore size of 5.4 nm and a surface area of 345 m 2 g -1 . Elemental analysis indicates the silicon/sulfur ratio to be 10:1, inferring one propylthiol substituent for every ten silica residues. The propylthiol modified SBA-15 was effective at significantly reducing high levels of patulin from aqueous solutions (pH 7.0) in batch sorption assays at room temperature. The material was less effective at lower pH; however heating low pH solutions and apple juice to 60 deg, C in the presence of propylthiol functionalized SBA-15 significantly reduced the levels of patulin in contaminated samples. Composite molecular models developed by semi-empirical PM3 and empirical force field methods support patulin permeation through the mesoporous channels of propylthiol functionalized SBA-15. Density functional study at the B3LYP/6-31G(d,p) level predicts the proposed patulin adducts formed by reaction with the thiol residues exhibit less electrophilic properties than patulin. It is demonstrated the use of propylthiol functionalized SBA-15 is a viable approach to reduce patulin levels in aqueous solutions, including contaminated apple juice.

  11. Rheological Properties of Aqueous Nanometric Alumina Suspensions

    Energy Technology Data Exchange (ETDEWEB)

    Li, Chuanping [Iowa State Univ., Ames, IA (United States)

    2004-01-01

    Colloidal processing is an effective and reliable approach in the fabrication of the advanced ceramic products. Successful colloidal processing of fine ceramic powders requires accurate control of the rheological properties. The accurate control relies on the understanding the influences of various colloidal parameters on the rheological properties. Almost all research done on the rheology paid less attention to the interactions of particle and solvent. However, the interactions of the particles are usually built up through the media in which the particles are suspended. Therefore, interactions of the particle with the media, the adsorbed layers on the particle surface, and chemical and physical properties of media themselves must influence the rheology of the suspension, especially for the dense suspensions containing nanosized particles. Relatively little research work has been reported in this area. This thesis addresses the rheological properties of nanometric alumina aqueous suspensions, and paying more attention to the interactions between particle and solvent, which in turn influence the particle-particle interactions. Dense nanometric alumina aqueous suspensions with low viscosity were achieved by environmentally-benign fructose additives. The rheology of nanometric alumina aqueous suspensions and its variation with the particle volume fraction and concentration of fructose were explored by rheometry. The adsorptions of solute (fructose) and solvent (water) on the nanometric alumina particle surfaces were measured and analyzed by TG/DSC, TOC, and NMR techniques. The mobility of water molecules in the suspensions and its variation with particle volume fractions and fructose additive were determined by the 17O NMR relaxation method. The interactions between the nanometric alumina particles in water and fructose solutions were investigated by AFM. The results indicated that a large number of water layers were physically bound on the particles

  12. Reverse osmosis separation of radium from dilute aqueous solutions

    International Nuclear Information System (INIS)

    Subramanian, K.S.; Sastri, V.S.

    1980-01-01

    Porous cellulose acetate membranes obtained from Osmonics Inc. were characterized in terms of pure water permeability constant, solute transport parameter, and mass transfer coefficient with aqueous sodium chloride solution as the reference system. Reverse osmosis separation behavior of radium-226 as nitrate, chloride, and sulfate salts was studied. Reverse osmosis method of removing radium-226 from aqueous solutions has been compared with other methods, and it has been shown to be one of the best methods for alleviating radium contamination problems

  13. Aqueous solutions of proline and NaCl studied by differential scanning calorimetry at subzero temperatures

    DEFF Research Database (Denmark)

    Rasmussen, Peter Have; Jørgensen, Bo; Nielsen, Jette

    1997-01-01

    The hydration properties of proline are studied by differential scanning calorimetry (DSC) in aqueous solutions during freezing to -60 degrees C and subsequent heating to +20 degrees C. The concentration of proline in the freeze concentrated solution was estimated to approximately 50 wt% (w/w) in...... plants and insects living under water stress conditions is discussed. (C) 1997 Elsevier Science B.V....

  14. Aqueous solutions/nuclear glasses interactions

    International Nuclear Information System (INIS)

    Delage, F.; Advocat, T.; Vernaz, E.; Crovisier, J.L.

    1991-01-01

    Interactions results of the borosilicate glass used in radioactive wastes confinement and aqueous solutions at various temperature and PH show that for the glass components: - the release rate evolution follows an Arrhenius law, - in acid PH, there is a selective dissolution, - in basic PH, there is a stoechiometric dissolution [fr

  15. Study on corrosion of carbon steel in DEA aqueous solutions

    Science.gov (United States)

    Yang, Jun Han; Xie, Jia Lin; Zhang, Li

    2018-02-01

    Corrosion of carbon steel in the CO2 capture process using diethanolamine (DEA) aqueous solutions was investigated. The effects of the mass concentrations of DEA, solution temperature and CO2 loading on the corrosion rate of carbon steel were demonstrated. The experimental results provided comprehensive information on the appropriate concentration range of DEA aqueous solutions under which low corrosion of carbon steel can be achieved.

  16. Enthalpies of Dissolution of Crystalline Naproxen Sodium in Water and Potassium Hydroxide Aqueous Solutions at 298 K

    Science.gov (United States)

    Lytkin, A. I.; Chernikov, V. V.; Krutova, O. N.; Bychkova, S. A.; Volkov, A. V.; Skvortsov, I. A.

    2018-03-01

    The enthalpies of dissolution of crystalline naproxen sodium in water and aqueous solutions of KOH at 298.15 K are measured by direct calorimetric means in a wide range of concentrations. The acid-base properties of naproxen sodium at ionic strength I 0 and I = 0.1 (KNO3) and a temperature of 298.15 K are studied by spectrophotometric means. The concentration and thermodynamic dissociation constants are determined. The standard enthalpies of the formation of naproxen sodium and the products of its dissociation in aqueous solution are calculated.

  17. Investigation of ionizing radiation effect on albumin aqueous solutions

    International Nuclear Information System (INIS)

    Sizikov, A.M.; Adeeva, L.N.; Ogryzkova, I.F.

    1986-01-01

    Gamma radiation effect on 0.1-0.5%-albumin aqueous solutions has been investigated; variations of viscosity and optical density of solutions at pH medium different values and completeness of protein separation owing to radiation coagulation have been determined. It is shown that due to radiation coagulation it is possible to quantitatively separate albumin from irradiated aqueous solutions. The albumin coagulation is caused by OH radicals the action of which on albumin macromolecules results in destruction of intramolecular bonds and albumin conformation transformations

  18. Zwitterionic polyacrylamides: synthesis, study of their properties in aqueous solution, study of their adsorption on clay particles; Derives zwitterioniques du polyacrylamide. Synthese et etude des proprietes en solution aqueuse et de l'adsorption sur argile

    Energy Technology Data Exchange (ETDEWEB)

    Carrette, P.L.

    1998-12-10

    Some zwitterionic polyacrylamides have been prepared and studied in aqueous solution. They are neutral polymers, whose charges are on the same lateral group: the positive charge is a quaternary ammonium and the negative charge is a phosphonate or a sulfonate group. Such poly-betaines have a zero net charge on a wide range of pH. They are prepared in salt-free aqueous solution by radical copolymerization of acrylamide with 3-[3-acrylamide-(propyl)dimethyl-ammonio] propane ethyl phosphate or 3-[3-acrylamide-(propyl)dimethyl-ammonio] propane sulfonate. The study has been restricted to copolymers with 1 to 10 % zwitterionic units and weight average molar masses between 1 and 2.10{sup 6} g/mol. The reactivity ratios have been determined. Their properties in solution and their adsorption on clay particles have been compared to the properties of polyacrylamide and partly hydrolyzed polyacrylamide. The use of the later polymers in petroleum industry is limited by the decrease of viscosity in presence of electrolytes, the precipitation with multi-valent cations and an important sensibility to the hydrolysis at basic pH and/or at high temperature. The rheological properties of zwitterionic polymers are controlled by electrostatic attractive forces between charges of opposite signs. Their viscosity increases as a function of ionic strength: the salts screen these attractive forces, increasing in this way the hydrodynamic volume (anti-polyelectrolyte behaviour). At high shear rates, their viscosity decreases less than in the case of usual polyacrylamide. Moreover, their resistance to hydrolysis is better and the precipitation by calcium salts is avoided unlike others charged polymers such as partly hydrolyzed polyacrylamides. Finally, their adsorption on clay particles (montmorillonite) is always twice higher than polyacrylamide adsorption whatever the salinity and the nature of salt (NaCl or KCl). In conclusion, even with small rates the incorporation of zwitterionic units in

  19. Aqueous pathways dominate permeation of solutes across Pisum sativum seed coats and mediate solute transport via diffusion and bulk flow of water.

    Science.gov (United States)

    Niemann, Sylvia; Burghardt, Markus; Popp, Christian; Riederer, Markus

    2013-05-01

    The permeability of seed coats to solutes either of biological or anthropogenic origin plays a major role in germination, seedling growth and seed treatment by pesticides. An experimental set-up was designed for investigating the mechanisms of seed coat permeation, which allows steady-state experiments with isolated seed coats of Pisum sativum. Permeances were measured for a set of organic model compounds with different physicochemical properties and sizes. The results show that narrow aqueous pathways dominate the diffusion of solutes across pea seed coats, as indicated by a correlation of permeances with the molecular sizes of the compounds instead of their lipophilicity. Further indicators for an aqueous pathway are small size selectivity and a small effect of temperature on permeation. The application of an osmotic water potential gradient across isolated seed coats leads to an increase in solute transfer, indicating that the aqueous pathways form a water-filled continuum across the seed coat allowing the bulk flow of water. Thus, the uptake of organic solutes across pea testae has two components: (1) by diffusion and (2) by bulk water inflow, which, however, is relevant only during imbibition. © 2012 Blackwell Publishing Ltd.

  20. Are nanoscale ion aggregates present in aqueous solutions of guanidinium salts?

    Science.gov (United States)

    Hunger, Johannes; Niedermayer, Stefan; Buchner, Richard; Hefter, Glenn

    2010-11-04

    A detailed investigation using broadband dielectric relaxation spectroscopy (DRS) has been made of the aqueous solutions of guanidinium chloride and carbonate, GdmCl(aq) and Gdm₂CO₃(aq), at 25 °C. The spectra indicate that Gdm(+) ions, C(NH₂)₃(+), do not bind strongly to water nor are they hydrophobically hydrated; rather they appear to have a most unusual ability to dissolve in water without altering its dynamics. Although DRS is particularly sensitive to the presence of ion pairs, only weak ion pairing was detected in Gdm₂CO₃(aq) solutions and none at all in GdmCl(aq). Surprisingly, no evidence was found for the existence of the higher order homo- and heteroionic nanoscale aggregates that have been identified in recent years by Mason and co-workers using molecular dynamics simulations and neutron diffraction. Possible reasons for this discrepancy are discussed. The present DR spectra and other solution properties of GdmCl(aq) and Gdm₂CO₃(aq), such as apparent molar volumes and electrical conductivities, are shown to have strong similarities to those of the corresponding Na+ salts. However, such solutions also differ remarkably from their Na(+) analogues (and all other simple electrolytes in aqueous solution) in that their average water relaxation times correlate strongly with their bulk viscosities. The biological implications of the present results are briefly discussed.

  1. Predicting accurate absolute binding energies in aqueous solution

    DEFF Research Database (Denmark)

    Jensen, Jan Halborg

    2015-01-01

    Recent predictions of absolute binding free energies of host-guest complexes in aqueous solution using electronic structure theory have been encouraging for some systems, while other systems remain problematic. In this paper I summarize some of the many factors that could easily contribute 1-3 kcal......-represented by continuum models. While I focus on binding free energies in aqueous solution the approach also applies (with minor adjustments) to any free energy difference such as conformational or reaction free energy differences or activation free energies in any solvent....

  2. Effects of mannose, fructose, and fucose on the structure, stability, and hydration of lysozyme in aqueous solution

    DEFF Research Database (Denmark)

    Rahim, Abdoul; Peters, Günther H.J.; Jalkanen, Karl J.

    2013-01-01

    The bio-protective properties of monosaccharaides, namely mannose, fructose and fucose, on the stability and dynamical properties of the NMR determined hen egg-white lysozyme structure have been investigated by means of molecular dynamics simulations at room temperature in aqueous solution and in...... of the solvent and sugar distributions around lysozyme was used to investigate the interfacial solvent and sugar structure near the protein surface.......The bio-protective properties of monosaccharaides, namely mannose, fructose and fucose, on the stability and dynamical properties of the NMR determined hen egg-white lysozyme structure have been investigated by means of molecular dynamics simulations at room temperature in aqueous solution and in 7...... and 13 wt % concentrations of the three sugars. Results are discussed in the framework of the bio-protective phenomena. The three sugars show similar bio-protective behaviours at room temperature (300 K) in the concentration range studied as shown by the small RMSDs of the resulting MD structures from...

  3. A new force field including charge directionality for TMAO in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Usui, Kota; Nagata, Yuki, E-mail: sulpizi@uni-mainz.de, E-mail: nagata@mpip-mainz.mpg.de; Hunger, Johannes; Bonn, Mischa [Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz (Germany); Sulpizi, Marialore, E-mail: sulpizi@uni-mainz.de, E-mail: nagata@mpip-mainz.mpg.de [Johannes Gutenberg University Mainz, Staudingerweg 7, 55099 Mainz (Germany)

    2016-08-14

    We propose a new force field for trimethylamine N-oxide (TMAO), which is designed to reproduce the long-lived and highly directional hydrogen bond between the TMAO oxygen (O{sub TMAO}) atom and surrounding water molecules. Based on the data obtained by ab initio molecular dynamics simulations, we introduce three dummy sites around O{sub TMAO} to mimic the O{sub TMAO} lone pairs and we migrate the negative charge on the O{sub TMAO} to the dummy sites. The force field model developed here improves both structural and dynamical properties of aqueous TMAO solutions. Moreover, it reproduces the experimentally observed dependence of viscosity upon increasing TMAO concentration quantitatively. The simple procedure of the force field construction makes it easy to implement in molecular dynamics simulation packages and makes it compatible with the existing biomolecular force fields. This paves the path for further investigation of protein-TMAO interaction in aqueous solutions.

  4. A new force field including charge directionality for TMAO in aqueous solution

    International Nuclear Information System (INIS)

    Usui, Kota; Nagata, Yuki; Hunger, Johannes; Bonn, Mischa; Sulpizi, Marialore

    2016-01-01

    We propose a new force field for trimethylamine N-oxide (TMAO), which is designed to reproduce the long-lived and highly directional hydrogen bond between the TMAO oxygen (O TMAO ) atom and surrounding water molecules. Based on the data obtained by ab initio molecular dynamics simulations, we introduce three dummy sites around O TMAO to mimic the O TMAO lone pairs and we migrate the negative charge on the O TMAO to the dummy sites. The force field model developed here improves both structural and dynamical properties of aqueous TMAO solutions. Moreover, it reproduces the experimentally observed dependence of viscosity upon increasing TMAO concentration quantitatively. The simple procedure of the force field construction makes it easy to implement in molecular dynamics simulation packages and makes it compatible with the existing biomolecular force fields. This paves the path for further investigation of protein-TMAO interaction in aqueous solutions.

  5. Photoluminescent properties of Y2O3:Eu3+ phosphors prepared via urea precipitation in non-aqueous solution

    International Nuclear Information System (INIS)

    Sun, Y.; Qi, L.; Lee, M.; Lee, B.I.; Samuels, W.D.; Exarhos, G.J.

    2004-01-01

    Europium-doped yttrium oxide phosphors were obtained by firing precursors prepared by urea precipitation in ethanol and ethylenediamine. The precipitation in non-aqueous solution was carried out in an autoclave at 150 deg. C to allow the decomposition of urea. The photoluminescent intensities of the phosphors prepared in ethanol and ethylenediamine increased by about 30% compared to that of the phosphor prepared by the conventional urea homogeneous precipitation in aqueous solution. Amorphous carbonates and amorphous hydroxides/carbonates mixtures were identified as precursors from ethanol and ethylenediamine, respectively. The morphology and particle size were studied by SEM and dynamic laser scattering method

  6. Sorption of a phenols mixture in aqueous solution with activated carbon

    International Nuclear Information System (INIS)

    Mejia M, D.

    2004-01-01

    The constant population growth and the quick industrialization have caused severe damages to our natural aquifer resources for a great variety of organic and inorganic pollutants. Among these they are those phenol compounds that are highly toxic, resistant (to the degradation chemistry) and poorly biodegradable. The phenolic compounds is used in a great variety of industries, like it is the production of resins, nylon, plastifiers, anti-oxidants, oil additives, drugs, pesticides, colorants, explosives, disinfectants and others. The disseminated discharges or effluents coming from the industrial processes toward lakes and rivers are causing a growing adverse effect in the environment, as well as a risk for the health. Numerous studies exist on the phenols removal and phenols substituted for very varied techniques, among them they are the adsorption in activated carbon. This finishes it has been used successfully for the treatment of residual waters municipal and industrial and of drinking waters and it is considered as the best technique available to eliminate organic compounds not biodegradable and toxic present in aqueous solution (US EPA, 1991). However a little information exists on studies carried out in aqueous systems with more of a phenolic compound. The activated carbon is broadly used as adsorbent due to its superficial properties in the so much treatment of water as of aqueous wastes, adsorbent for the removal of organic pollutants. The main objective of this work is the adsorption of a aqueous mixture of phenol-4 chloro phenol of different concentrations in activated carbon of mineral origin of different meshes and to diminish with it their presence in water. The experiments were carried out for lots, in normal conditions of temperature and pressure. The experimental results show that the removal capacity depends so much of the superficial properties of the sorbent like of the physical properties and chemical of the sorbate. The isotherms were carried

  7. Antimony removal from aqueous solutions using Zirconium hydroxide

    International Nuclear Information System (INIS)

    Petrescu, D.; Velciu, L.; Bucur, C.

    2016-01-01

    In this paper it is presented an experimental test for non-radioactive antimony removal from aqueous solutions using zirconium hydroxide powder. Also, it was studied how the temperature and pH influences antimony adsorption onto zirconium hydroxide surface. After the adsorption, solutions were filtered on Cellulose Mixed Ester Membrane with 0.2 μm pore size to remove the zirconium powder and then the aqueous solutions were sent to Inductively Coupled Plasma Optic Emission Spectrometry (ICP-OES) for quantitative analysis of Sb. Zirconium hydroxide powders were examined by optical microscopy. For the solutions that were tested at pH 4.5 and 10.2 the antimony concentration dropped below the detection limit of ICP-OES device, proof of antimony adsorption on zirconium hydroxide. Also, for the other tested solutions which had pH=12 the antimony concentration reduced with 77% and 80%. The temperature had no influence upon adsorption mechanism. (authors)

  8. Status of determining transuranic nuclides speciation in aqueous solution with laser spectrometry

    International Nuclear Information System (INIS)

    Wang Bo; Liu Dejun; Yao Jun; Chen Xi; Long Haoqi; Zeng Jishu; Su Xiguang; Fan Xianhua

    2007-01-01

    The knowledge about speciation of transuranic nuclides in aqueous solution is a basis for understanding the chemical and migration behavior of transuranic nuclides in aqueous solution. The speciation of transuranic nuclides with trace concentration is complicated in near neutral aqueous solutions, including change of oxidation state, complexation and colloid generation, etc. The concentrations of transuranium in near neutral aqueous solution usually below the sensitivity range of method such as conventional absorption spectroscopy. The radioactive analysis method has a very low detection limits for radionuclides, however, it wouldn' t allow the direct measurement of the transuranic species. In contrast with these methods, laser spectroscopy is an ideal method with high sensitivity, and non-contact and non-destructive for determining the speciation of transuranic nuclides. This paper summarizes the status and application of LIPAS (Laser-induced Photoacoustic Spectrometry), LIBD (Laser-induced Breakdown Detection) and TRLFS (Time-resolved Laser Fluorescence Spectrometry) to determine the speciation of transuranic nuclides with trace concentration in aqueous solutions. (authors)

  9. Process for the recovery of alkali metal salts from aqueous solutions thereof

    International Nuclear Information System (INIS)

    Vitner, J.

    1984-01-01

    In an integrated process for the recovery of alkakli metal phenates and carboxylates from aqueous solutions thereof, the aqueous solution is spray dried and the drying gas stream is contacted with an aqueous alkali metal salt solution which dissolves the particles of the alkali metal salt that were entrained in the drying gas stream. The salt-free inert gas stream is then dried, heated, and returned to the spray dryer

  10. Influence of formulation and processing variables on properties of itraconazole nanoparticles made by advanced evaporative precipitation into aqueous solution.

    Science.gov (United States)

    Bosselmann, Stephanie; Nagao, Masao; Chow, Keat T; Williams, Robert O

    2012-09-01

    Nanoparticles, of the poorly water-soluble drug, itraconazole (ITZ), were produced by the Advanced Evaporative Precipitation into Aqueous Solution process (Advanced EPAS). This process combines emulsion templating and EPAS processing to provide improved control over the size distribution of precipitated particles. Specifically, oil-in-water emulsions containing the drug and suitable stabilizers are sprayed into a heated aqueous solution to induce precipitation of the drug in form of nanoparticles. The influence of processing parameters (temperature and volume of the heated aqueous solution; type of nozzle) and formulation aspects (stabilizer concentrations; total solid concentrations) on the size of suspended ITZ particles, as determined by laser diffraction, was investigated. Furthermore, freeze-dried ITZ nanoparticles were evaluated regarding their morphology, crystallinity, redispersibility, and dissolution behavior. Results indicate that a robust precipitation process was developed such that size distribution of dispersed nanoparticles was shown to be largely independent across the different processing and formulation parameters. Freeze-drying of colloidal dispersions resulted in micron-sized agglomerates composed of spherical, sub-300-nm particles characterized by reduced crystallinity and high ITZ potencies of up to 94% (w/w). The use of sucrose prevented particle agglomeration and resulted in powders that were readily reconstituted and reached high and sustained supersaturation levels upon dissolution in aqueous media.

  11. Evolution of ZnS Nanoparticles via Facile CTAB Aqueous Micellar Solution Route: A Study on Controlling Parameters

    Directory of Open Access Journals (Sweden)

    Gradzielski Michael

    2008-01-01

    Full Text Available Abstract Synthesis of semiconductor nanoparticles with new photophysical properties is an area of special interest. Here, we report synthesis of ZnS nanoparticles in aqueous micellar solution of Cetyltrimethylammonium bromide (CTAB. The size of ZnS nanodispersions in aqueous micellar solution has been calculated using UV-vis spectroscopy, XRD, SAXS, and TEM measurements. The nanoparticles are found to be polydispersed in the size range 6–15 nm. Surface passivation by surfactant molecules has been studied using FTIR and fluorescence spectroscopy. The nanoparticles have been better stabilized using CTAB concentration above 1 mM. Furthermore, room temperature absorption and fluorescence emission of powdered ZnS nanoparticles after redispersion in water have also been investigated and compared with that in aqueous micellar solution. Time-dependent absorption behavior reveals that the formation of ZnS nanoparticles depends on CTAB concentration and was complete within 25 min.

  12. An accurate coarse-grained model for chitosan polysaccharides in aqueous solution.

    Directory of Open Access Journals (Sweden)

    Levan Tsereteli

    Full Text Available Computational models can provide detailed information about molecular conformations and interactions in solution, which is currently inaccessible by other means in many cases. Here we describe an efficient and precise coarse-grained model for long polysaccharides in aqueous solution at different physico-chemical conditions such as pH and ionic strength. The Model is carefully constructed based on all-atom simulations of small saccharides and metadynamics sampling of the dihedral angles in the glycosidic links, which represent the most flexible degrees of freedom of the polysaccharides. The model is validated against experimental data for Chitosan molecules in solution with various degree of deacetylation, and is shown to closely reproduce the available experimental data. For long polymers, subtle differences of the free energy maps of the glycosidic links are found to significantly affect the measurable polymer properties. Therefore, for titratable monomers the free energy maps of the corresponding links are updated according to the current charge of the monomers. We then characterize the microscopic and mesoscopic structural properties of large chitosan polysaccharides in solution for a wide range of solvent pH and ionic strength, and investigate the effect of polymer length and degree and pattern of deacetylation on the polymer properties.

  13. An accurate coarse-grained model for chitosan polysaccharides in aqueous solution.

    Science.gov (United States)

    Tsereteli, Levan; Grafmüller, Andrea

    2017-01-01

    Computational models can provide detailed information about molecular conformations and interactions in solution, which is currently inaccessible by other means in many cases. Here we describe an efficient and precise coarse-grained model for long polysaccharides in aqueous solution at different physico-chemical conditions such as pH and ionic strength. The Model is carefully constructed based on all-atom simulations of small saccharides and metadynamics sampling of the dihedral angles in the glycosidic links, which represent the most flexible degrees of freedom of the polysaccharides. The model is validated against experimental data for Chitosan molecules in solution with various degree of deacetylation, and is shown to closely reproduce the available experimental data. For long polymers, subtle differences of the free energy maps of the glycosidic links are found to significantly affect the measurable polymer properties. Therefore, for titratable monomers the free energy maps of the corresponding links are updated according to the current charge of the monomers. We then characterize the microscopic and mesoscopic structural properties of large chitosan polysaccharides in solution for a wide range of solvent pH and ionic strength, and investigate the effect of polymer length and degree and pattern of deacetylation on the polymer properties.

  14. The effect of physiologic aqueous solutions on the perovskite material lead-lanthanum-zirconium titanate (PLZT)

    Science.gov (United States)

    Foster, William J.; Meen, James K.; Fox, Donald A.

    2016-01-01

    Context Perovskite compounds, including Lead-Lanthanum-Zirconium Titanate (PLZT), have wide technological application because of their unique physical properties. The use of PLZT in neuro-prosthetic systems, such as retinal implants, have been discussed in a number of publications. Since inorganic lead is a retinotoxic compound that produces retinal degeneration, the long-term stability of PLZT in aqueous biological solutions must be determined. Objective We evaluated the stability and effects of prolonged immersion of a PLZT-coated crystal in a buffered balanced salt solution. Materials and Methods Scanning Electron Microscopy and Electron Dispersive Spectroscopy (EDS) using a JEOL JSM 5410 microscope equipped with EDS were utilized to evaluate the samples before and after prolonged immersion. Results We found that lead and other constituents of PLZT leached into the surrounding aqueous medium. Discussion By comparing the unit cell of PLZT with that of CaTiO3, which has been found to react with aqueous fluids, Lead is in the same site in PLZT as Ca is in CaTiO3. It is thus reasonable that PLZT will react with aqueous solutions. Conclusion The results suggest that PLZT must either be coated with a protective layer or is not appropriate for long-term in vivo or in vitro biological applications. PMID:22697294

  15. Dissolution of lignin in green urea aqueous solution

    Science.gov (United States)

    Wang, Jingyu; Li, Ying; Qiu, Xueqing; Liu, Di; Yang, Dongjie; Liu, Weifeng; Qian, Yong

    2017-12-01

    The dissolution problem is the main obstacle for the value-added modification and depolymerization of industrial lignin. Here, a green urea aqueous solution for complete dissolution of various lignin is presented and the dissolution mechanism is analyzed by AFM, DLS and NMR. The results show that the molecular interaction of lignin decreases from 32.3 mN/m in pure water to 11.3 mN/m in urea aqueous solution. The immobility of 1H NMR spectra and the shift of 17O NMR spectra of urea in different lignin/urea solutions indicate that the oxygen of carbonyl in urea and the hydrogen of hydroxyl in lignin form new hydrogen bonds and break the original hydrogen bonds among lignin molecules. The shift of 1H NMR spectra of lignin and the decrease of interactions in model compound polystyrene indicate that urea also breaks the π-π interactions between aromatic rings of lignin. Lignin dissolved in urea aqueous has good antioxidant activity and it can scavenge at least 63% free radicals in 16 min.

  16. Adsorption of nicotine on different zeolite types, from aqueous solutions

    Directory of Open Access Journals (Sweden)

    Stošić Dušan K.

    2007-01-01

    Full Text Available The plant alkaloid, nicotine, is a strongly toxic heterocyclic compound: the lethal dose for an adult human being (40-60 mg is importantly lower in comparison with the other known poisons such as arsenic or strychni­ne. Cigarettes represent "the most toxic and addictive form of nicotine". Besides the negative effects of nicotine on public health produced by self-administration, recently another potentially very dangerous effect has been recognized: because of its miscibility with water, nicotine can be found in industrial wastewaters, and consequently, in groundwater. Therefore, the problem of nicotine removal from aqueous solutions has became an interesting topic. In this work, the removal of nicotine has been probed by adsorption on solid materials. Adsorption of nicotine on different zeolites (clinoptilolite, ZSM-5 and β zeolite and on activated carbon was investigated from aqueous solutions, at 298 K. The obtained results are presented as adsorption isotherms: the amount of adsorbed nicotine as a function of equilibrium concentration. These data were obtained from the residual amount of nicotine in the aqueous phase, by the use of UV spectroscopy. The highest amounts of adsorbed nicotine was found for activated carbon and p zeolite (~ mmol·g-1. The attempt to modify the adsorption properties of ZSM-5 zeolite has been also done: ZSM-5 was modified by ion-exchange with VIII group metal (Cu2+ and Fe3+. In addition, the adsorption of nicotine on ZSM-5 zeolite with different Si/Al ratios has been done. It has been noticed that ion-exchange did not improve the adsorption possibilities, while the adsorption was importantly lower in the case of higher silicon content in ZMS-5 structure. 13C NMR spectra were collected for suspensions formed of solid adsorbent and aqueous solution of nicotine; in this way, the part of nicotine molecule which is most probably connected with the adsorbent was recognized.

  17. Rate Constants for Reactions of Radiation-Produced Transients in Aqueous Solutions of Actinides

    International Nuclear Information System (INIS)

    Gordon, S.; Sullivan, J.C.; Ross, A.B.

    1986-01-01

    Rate constants have been critically compiled for reactions of ions of the actinides Am, Cf, Cm, Np, Pu, Th, and U, as well as the element Tc, in different oxidation states with various chemical species in aqueous solution. The reactants include products of the radiolysis of water (hydrated electrons, hydrogen atoms, hydroxyl radicals, hydrogen peroxide) and transient species derived from other solutes (e.g., carbonate radical). The data are useful in the estimation of migration properties of actinides, which are relevant to waste management studies

  18. A Concise Equation of State for Aqueous Solutions of Electrolytes Incorporating Thermodynamic Laws and Entropy

    Directory of Open Access Journals (Sweden)

    Raji Heyrovská

    2004-03-01

    Full Text Available Abstract: Recently, the author suggested a simple and composite equation of state by incorporating fundamental thermodynamic properties like heat capacities into her earlier concise equation of state for gases based on free volume and molecular association / dissociation. This work brings new results for aqueous solutions, based on the analogy of the equation of state for gases and solutions over wide ranges of pressures (for gases and concentrations (for solutions. The definitions of entropy and heat energy through the equation of state for gases, also holds for solutions.

  19. Adsorption of and acidic dye from aqueous solution by surfactant modified bentonite

    International Nuclear Information System (INIS)

    Bouberka, Z.; Khenifi, A.; Belkaid, N.; Ait Mahamed, H.; Haddou, B.; Derriche, Z.

    2009-01-01

    The aim of this paper is to study the adsorption of an acidic dye S. Y. 4 GL (i.e: Supranol yellow 4GL) from aqueous solution on inorgano-organo clay. Bentonite is a kind of natural clay with good exchanging ability. By exchanging its inter lamellar cations with Cetyltrimethylammonium bromide (CTAB) and hydroxy aluminic or chromium poly cations, the properties of natural bentonite can be greatly improved. (Author)

  20. Superhydrophobic copper surfaces fabricated by fatty acid soaps in aqueous solution for excellent corrosion resistance

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Wenlong; Hu, Yuanyuan; Bao, Wenda; Xie, Xiaoyu; Liu, Yiran; Song, Aixin, E-mail: songaixin@sdu.edu.cn; Hao, Jingcheng

    2017-03-31

    Highlights: • The superhydrophobic property can be realized in a much quicker process (7.5 min) in aqueous solution than in ethanol. • The fabrication process of superhydrophobic metal surfaces greatly increases the safety in industrial manufacture in commercial scale. • The superhydrophobic copper surfaces show excellent corrosion resistance. - Abstract: A simple and safe one-step immersion method was developed to obtain the stable superhydrophobic copper surfaces with excellent corrosion resistance ability using fatty acids in water-medium instead of ethanol. An organic alkali, N,N-dimethylcyclohexylamine (DMCHA), was chosen to solve the poor solubility of fatty acids in water and the high Krafft point of carboxylate salts with inorganic counterions. The superhydrophobic property can be realized in a much quicker process (7.5 min) in aqueous solution than in ethanol (more than 2 d), which is universally feasible for the fabrication of superhydrophobic metal surfaces in industry scale, thereby greatly increasing the safety in industrial manufacture.

  1. Photoluminescence Spectroscopy of Rhodamine 800 Aqueous Solution and Dye-Doped Polymer Thin-Film: Concentration and Solvent Effects

    Science.gov (United States)

    Le, Khai Q.; Dang, Ngo Hai

    2018-05-01

    This paper investigates solvent and concentration effects on photoluminescence (PL) or fluorescence properties of Rhodamine 800 (Rho800) dyes formed in aqueous solution and polymer thin-film. Various commonly used organic solvents including ethanol, methanol and cyclopentanol were studied at a constant dye concentration. There were small changes in the PL spectra for the different solvents in terms of PL intensity and peak wavelength. The highest PL intensity was observed for cyclopentanol and the lowest for ethanol. The longest peak wavelength was found in cyclopentanol (716 nm) and the shortest in methanol (708 nm). Dissolving the dye powder in the methanol solvent and varying the dye concentration in aqueous solution from the high concentrated solution to highly dilute states, the wavelength tunability was observed between about 700 nm in the dilute state and 730 nm at high concentration. Such a large shift may be attributed to the formation of dye aggregates. Rho800 dye-doped polyvinyl alcohol (PVA) polymer thin-film was further investigated. The PL intensity of the dye in the form of thin-film is lower than that of the aqueous solution form whereas the peak wavelength is redshifted due to the presence of PVA. This paper, to our best knowledge, reports the first study of spectroscopic properties of Rho800 dyes in various forms and provides useful guidelines for production of controllable organic luminescence sources.

  2. Volumetric properties of glucose in aqueous HCI solutions at temperatures from 278.15 to 318.15 K

    Institute of Scientific and Technical Information of China (English)

    ZHUO Kelei; ZHANG Qiufen; XUAN Xiaopeng; ZHANG Hucheng; WANG Jianji

    2007-01-01

    Densities have been measured for Glucose+HC1 +Water at 10-degree intervals from 278.15 to 318.15 K.The apparent molar volumes (Vφ,G) and standard partial molar volumes (V0φ,G) for Glucose in aqueous solution of 0.2,0.4,0.7,1.1,1.6,2.1 mol.kg-1 HCI have been calculated as well as volumetric interaction parameters (VEG) for Glucose-HC1 in water and standard partial molar expansion coefficients ((e)V0φ,G/(e)T)p.Results show that (1) the apparent molar volume for Glucose in aqueous HC1 solutions increases lineally with increasing molality of Glucose and HC1; (2) V0φ,Gfor Glucose in aqueous HC1 solutions increases lineally with increasing molality of HC1; (3) the volumetric interaction parameters for Glucose-HC1 pair in water are small positive and vary slightly with temperature; (4) the relation between V0φ,G and temperature exists as V0φ,G =α0+α1(T-273.15 K)2/3;(5)values of((e)V0φ,G/(e)T)p are positive and increase as temperatures rise,and at given temperatures decrease slightly with increasing molalities of HC1,indicating that the hydration of glucose decreases with increasing temperature and molality of HCI.These phenomena are interpreted successfully by the structure interaction model.

  3. γ-Irradiation-induced radiolysis of inulin in aqueous solutions

    International Nuclear Information System (INIS)

    Tsyba, I.A.; Revina, A.A.; Shostenko, A.G.

    1997-01-01

    Radiochemical transformations of inulin in aqueous solutions, in air, in the presence of inert gases, helium, nitrogen and in nitrous oxide exposed to various doses of 60 Co γ-irradiation were investigated. It was shown that interactions in inulin with OH radicals are principally responsible for radiolytic decomposition of inulin. The data on radiolysis of more simple model systems were used to make available decomposition spectra of γ-irradiated aerated aqueous solution of inulin. 9 refs., 6 figs

  4. Graph Theory and Ion and Molecular Aggregation in Aqueous Solutions

    Science.gov (United States)

    Choi, Jun-Ho; Lee, Hochan; Choi, Hyung Ran; Cho, Minhaeng

    2018-04-01

    In molecular and cellular biology, dissolved ions and molecules have decisive effects on chemical and biological reactions, conformational stabilities, and functions of small to large biomolecules. Despite major efforts, the current state of understanding of the effects of specific ions, osmolytes, and bioprotecting sugars on the structure and dynamics of water H-bonding networks and proteins is not yet satisfactory. Recently, to gain deeper insight into this subject, we studied various aggregation processes of ions and molecules in high-concentration salt, osmolyte, and sugar solutions with time-resolved vibrational spectroscopy and molecular dynamics simulation methods. It turns out that ions (or solute molecules) have a strong propensity to self-assemble into large and polydisperse aggregates that affect both local and long-range water H-bonding structures. In particular, we have shown that graph-theoretical approaches can be used to elucidate morphological characteristics of large aggregates in various aqueous salt, osmolyte, and sugar solutions. When ion and molecular aggregates in such aqueous solutions are treated as graphs, a variety of graph-theoretical properties, such as graph spectrum, degree distribution, clustering coefficient, minimum path length, and graph entropy, can be directly calculated by considering an ensemble of configurations taken from molecular dynamics trajectories. Here we show percolating behavior exhibited by ion and molecular aggregates upon increase in solute concentration in high solute concentrations and discuss compelling evidence of the isomorphic relation between percolation transitions of ion and molecular aggregates and water H-bonding networks. We anticipate that the combination of graph theory and molecular dynamics simulation methods will be of exceptional use in achieving a deeper understanding of the fundamental physical chemistry of dissolution and in describing the interplay between the self-aggregation of solute

  5. Graph Theory and Ion and Molecular Aggregation in Aqueous Solutions.

    Science.gov (United States)

    Choi, Jun-Ho; Lee, Hochan; Choi, Hyung Ran; Cho, Minhaeng

    2018-04-20

    In molecular and cellular biology, dissolved ions and molecules have decisive effects on chemical and biological reactions, conformational stabilities, and functions of small to large biomolecules. Despite major efforts, the current state of understanding of the effects of specific ions, osmolytes, and bioprotecting sugars on the structure and dynamics of water H-bonding networks and proteins is not yet satisfactory. Recently, to gain deeper insight into this subject, we studied various aggregation processes of ions and molecules in high-concentration salt, osmolyte, and sugar solutions with time-resolved vibrational spectroscopy and molecular dynamics simulation methods. It turns out that ions (or solute molecules) have a strong propensity to self-assemble into large and polydisperse aggregates that affect both local and long-range water H-bonding structures. In particular, we have shown that graph-theoretical approaches can be used to elucidate morphological characteristics of large aggregates in various aqueous salt, osmolyte, and sugar solutions. When ion and molecular aggregates in such aqueous solutions are treated as graphs, a variety of graph-theoretical properties, such as graph spectrum, degree distribution, clustering coefficient, minimum path length, and graph entropy, can be directly calculated by considering an ensemble of configurations taken from molecular dynamics trajectories. Here we show percolating behavior exhibited by ion and molecular aggregates upon increase in solute concentration in high solute concentrations and discuss compelling evidence of the isomorphic relation between percolation transitions of ion and molecular aggregates and water H-bonding networks. We anticipate that the combination of graph theory and molecular dynamics simulation methods will be of exceptional use in achieving a deeper understanding of the fundamental physical chemistry of dissolution and in describing the interplay between the self-aggregation of solute

  6. Speciation analysis on Eu(3) in aqueous solution using laser-induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Hotokezaka, H.; Tanaka, S.; Nagasaki, S.

    2001-01-01

    Investigation of the chemical behaviour of lanthanides and actinides in the geosphere is important for the safety assessment of high-level radioactive waste disposal. However, determination of speciation for lanthanides and actinides is difficult, because it is too hard to distinguish between metal ion and colloidal metal in aqueous solution. Laser-induced breakdown spectroscopy (LIBS) can detect both ions and microparticles of metals in aqueous solution, especially, high sensitive to microparticles. In this study, we analysed Eu(III) ion and Eu 2 O 3 particle in aqueous solution by LIBS, and measured the hydrolysis behaviour of Eu(III) in aqueous solution. Furthermore, we tried to detect the plasma emission of Eu(III) ions sorbed on TiO 2 particles, and also tried to observe the adsorption behaviour of Eu(III) ions onto TiO 2 particles in aqueous solution. (authors)

  7. Colloidal copper in aqueous solutions: radiation-chemical reduction, mechanism of formation and properties

    International Nuclear Information System (INIS)

    Ershov, B.G.

    1994-01-01

    Colloidal copper was obtained upon γ-irradiation of aqueous solutions of divalent copper perchlorate in the presence of alcohol and polyethyleneimine (PEI). The sols were in the form of spherical particles 4 nm in diameter, which were promptly oxidized by oxygen or other oxidants. The copper ions were reduced on the surface of silver sols. The optical parameters of the obtained bimetallic particles were studied. The copper ions led to the broadening and shift of the absorption bands of the silver sols to the UV region

  8. EXTRACTION OF URANYL NITRATE FROM AQUEOUS SOLUTIONS

    Science.gov (United States)

    Furman, N.H.; Mundy, R.J.

    1957-12-10

    An improvement in the process is described for extracting aqueous uranyl nitrate solutions with an organic solvent such as ether. It has been found that the organic phase will extract a larger quantity of uranyl nitrate if the aqueous phase contains in addition to the uranyl nitrate, a quantity of some other soluble nitrate to act as a salting out agent. Mentioned as suitable are the nitrates of lithium, calcium, zinc, bivalent copper, and trivalent iron.

  9. An Evaluation of Four Electrolyte Models for the Prediction of Thermodynamic Properties of Aqueous Electrolyte Solutions

    Directory of Open Access Journals (Sweden)

    Kamalodin Momeni

    2017-04-01

    Full Text Available In this work, the performance of four electrolyte models for prediction the osmotic and activity coefficients of different aqueous salt solutions at 298 K, atmospheric pressure and in a wide range of concentrations are evaluated. In two of these models, (electrolyte Non-Random Two-Liquid e-NRTL and Mean Spherical Approximation-Non-Random Two-Liquid MSA-NRTL, association between ions of opposite charges for simplification purposes is ignored and in the other two ones, (Associative Mean Spherical Approximation-Non-Random Two-Liquid AMSA-NRTL and Binding Mean Spherical Approximation BiMSA association and solvation effects are considered. The predictions of these four models for the osmotic and activity coefficients of electrolyte solutions at 298 K and atmospheric pressure are compared with the experimental data reported in the literature. This comparison includes, 28 different aqueous salt solutions including thio-cyanates, perchlorates, nitrates, hydroxides, quaternary ammonium salts and others. The results show, the performance of models that consider association effects are better than others especially for higher salt concentrations. However, the best performance belongs to BiMSA model which has some parameters with physical meaning.

  10. Solution properties and taste behavior of lactose monohydrate in aqueous ascorbic acid solutions at different temperatures: Volumetric and rheological approach.

    Science.gov (United States)

    Sarkar, Abhijit; Sinha, Biswajit

    2016-11-15

    The densities and viscosities of lactose monohydrate in aqueous ascorbic acid solutions with several molal concentrations m=(0.00-0.08)molkg(-1) of ascorbic acid were determined at T=(298.15-318.15)K and pressure p=101kPa. Using experimental data apparent molar volume (ϕV), standard partial molar volume (ϕV(0)), the slope (SV(∗)), apparent specific volumes (ϕVsp), standard isobaric partial molar expansibility (ϕE(0)) and its temperature dependence [Formula: see text] the viscosity B-coefficient and solvation number (Sn) were determined. Viscosity B-coefficients were further employed to obtain the free energies of activation of viscous flow per mole of the solvents (Δμ1(0≠)) and of the solute (Δμ2(0≠)). Effects of molality, solute structure and temperature and taste behavior were analyzed in terms of solute-solute and solute-solvent interactions; results revealed that the solutions are characterized predominantly by solute-solvent interactions and lactose monohydrate behaves as a long-range structure maker. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Effect of textural and chemical characteristics of activated carbons on phenol adsorption in aqueous solutions

    OpenAIRE

    Vargas Diana P.; Giraldo Liliana; Moreno-Piraján Juan Carlos

    2017-01-01

    The effect of textural and chemical properties such as: surface area, pore volume and chemical groups content of the granular activated carbon and monoliths on phenol adsorption in aqueous solutions was studied. Granular activated carbon and monolith samples were produced by chemical activation. They were characterized by using N2 adsorption at 77 K, CO2 adsorption at 273 K, Boehm Titrations and immersion calorimetry in phenol solutions. Microporous materials with different pore size distribu...

  12. Extraction of americium from acid aqueous solutions by diethyl-2-hexyl-pyro-phosphoric acid

    International Nuclear Information System (INIS)

    Guillaume, Bernard

    1971-02-01

    After having outlined the interesting properties of americium and the difficulties of its recovery, the author reports the study of the mechanism of extraction of americium from acid aqueous solutions by using the diethyl-2hexyl-pyro-phosphoric acid. Several aspects are thus discussed: influence of concentration of H 2 DEHPP, influence of the acidity of the aqueous phase, saturation of extracting agent, influence of the diluting agent, complexing of americium, influence of other cations. In a second part, the author reports the application to the recovery of americium from effluents, and discusses the obtained results

  13. Incorporating Pitzer equations in a new thermodynamic model for the prediction of acid gases solubility in aqueous alkanolamine solutions

    NARCIS (Netherlands)

    Alhseinat, E.; Mota Martinez, M.; Peters, C.J.; Banat, F.

    2014-01-01

    In gas sweetening, acid gases such as CO2 and/or H2S are usually removed by "chemical" absorption through aqueous amine solutions such as N-Methyldiethanolamine (MDEA) solution. Reliable prediction of equilibrium properties (vapor–liquid equilibrium and species distribution) is needed for a rigorous

  14. Supercooling of aqueous dimethylsulfoxide solution at normal and high pressures: Evidence for the coexistence of phase-separated aqueous dimethylsulfoxide solutions of different water structures

    Science.gov (United States)

    Kanno, H.; Kajiwara, K.; Miyata, K.

    2010-05-01

    Supercooling behavior of aqueous dimethylsulfoxide (DMSO) solution was investigated as a function of DMSO concentration and at high pressures. A linear relationship was observed for TH (homogeneous ice nucleation temperature) and Tm (melting temperature) for the supercooling of aqueous DMSO solution at normal pressure. Analysis of the DTA (differential thermal analysis) traces for homogeneous ice crystallization in the bottom region of the TH curve for a DMSO solution of R =20 (R: moles of water/moles of DMSO) at high pressures supported the contention that the second critical point (SCP) of liquid water should exist at Pc2=˜200 MPa and at Tc2pressure of SCP, Tc2: temperature of SCP). The presence of two TH peaks for DMSO solutions (R =15, 12, and 10) suggests that phase separation occurs in aqueous DMSO solution (R ≤15) at high pressures and low temperatures (pressure dependence of the two TH curves for DMSO solutions of R =10 and 12 indicates that the two phase-separated components in the DMSO solution of R =10 have different liquid water structures [LDL-like and HDL-like structures (LDL: low-density liquid water, HDL: high-density liquid water)] in the pressure range of 120-230 MPa.

  15. Self-aggregation of liquids from biomass in aqueous solution

    International Nuclear Information System (INIS)

    Lomba, Laura; Giner, Beatriz; Zuriaga, Estefanía; Moya, Juana; Lafuente, Carlos

    2013-01-01

    Highlights: • Aggregation behaviour of liquids from biomass in aqueous solution has been studied. • Standard Gibbs free energies of aggregation have been calculated. • Solubility in water of these compounds has been determined. • Critical aggregation concentration decreases as the solubility in water does. -- Abstract: Aggregation of several chemicals from biomass: furfural derived compounds (furfural, 5-methylfurfural, furfuryl alcohol and tetrahydrofurfuryl alcohol), lactate derived compounds (methyl lactate, ethyl lactate and butyl lactate), acrylate derived compound (methyl acrylate) and levulinate compounds (methyl levulinate, ethyl levulinate and butyl levulinate) in aqueous solution has been characterised at T = 298.15 K through density, ρ, speed of sound, u, and isentropic compressibilities, κ S , measurements. In addition the standard Gibbs free energies of aggregation have been also calculated. Furthermore, in order to deepen insight the behaviour of these chemicals in aqueous solution, the solubility of these compounds has been measured at T = 298.15 K

  16. Formation and properties of radiocolloids in aqueous solution - a literature survey

    International Nuclear Information System (INIS)

    Olofsson, U.; Allard, B.; Andersson, K.; Torstenfelt, B.

    1981-06-01

    The sorption of radionuclides on various rocks and minerals has been studied within many national waste programs as a means of predicting the migration behaviour of radionuclides that might be released from e.g. an underground repository for radioactive waste. One major objection against the conclusions that can be drawn from laboratory sorption studies is that the possibility of a formation of small fractions of highly mobile particulates are usually not considered. The elements, present in spent nuclear fuel, which are most likely to form colloid species would be hydrolyzable elements like the actinides and possibly Sr as well as Pb and Cu representing the encapsulation material. Moreover the radionuclides would be present in aqueous solutions in very low concentrations and under these conditions other phenomena occurs than at macroconcentrations. This literature survey is meant to be a basis for further studies on the formation and transport of radiocolloids in the groundwater-rock environment. The colloids will probably not be retarded by the same mechanisms as dissolved species in true solution, but may in some cases migrate with the same velocity as the groundwater. (Auth.)

  17. Preparation and tribological properties of inclusion complex of β-cyclodextrin/dialkyl pentasulfide as additive in PEG-600 aqueous solution

    International Nuclear Information System (INIS)

    Guan, Jiju; Xu, Xuefeng; Li, Gan; Peng, Wei

    2014-01-01

    The inclusion complex of β-cyclodextrin (β-CD) and dialkyl pentasulfide (DPS), in which DPS was incorporated into β-CD cavities, was prepared by a co-precipitation method. The tribological properties of the complex used as lubricant additive in PEG 600 aqueous solution were investigated by a four-ball tester. The complex exhibited better tribological properties than β-CD under different loads, and also showed better anti-friction performance than DPS in the latter half of the test duration. The tribological action mechanism of the complex on a steel surface was studied according to the X-ray photoelectron spectroscopy (XPS) analyses. The β-CD molecules of the complexes were decomposed into various molecular fragments and the DPS molecules were released under the friction condition. It revealed that thiolate and ferrous sulfide (FeS) films formed by DPS played a major role, and iron alkoxide and carbon deposition films formed by the friction fragments of β-CD mainly exhibited anti-friction property on FeS-to-FeS interface. The interactions among different films led to the formation of a mixed boundary lubrication film.

  18. Zeolites as alcohol adsorbents from aqueous solutions

    Directory of Open Access Journals (Sweden)

    Cekova Blagica

    2006-01-01

    Full Text Available The potential usage of zeolites as adsorbents for the removal of organic molecules from water was investigated in a series of experiments with aqueous solutions of lower alcohols. This could represent a simple solution to the problem of cleaning up industrial wastewater as well as recovering valuable chemicals at relatively low costs. Adsorption isotherms of the Langmuir type were applied, and calculations showed that the amount of propanol adsorbed on silicalite corresponded to approximately 70% of the pore volume. The adsorption process is simple, and recovery of the more concentrated products is easily done by heat treatment and/or at lowered pressures. Adsorption experiments with aqueous acetone showed that silicalite had approximately the same adsorption capacity for acetone as for n-propanol. Heats of adsorption were determined calorimetrically.

  19. Bromfenac ophthalmic solution 0.09 %: human aqueous humor concentration detected by high-performance liquid chromatography.

    Science.gov (United States)

    Macrì, Angelo; Vagge, Aldo; Salis, Annalisa; Fucile, Carmen; Marini, Valeria; Martelli, Antonietta; Giuffrida, Sebastiano; Iester, Michele; Damonte, Gianluca; Mattioli, Francesca

    2017-04-01

    The purpose of this study was to evaluate the aqueous humor concentrations of bromfenac ophthalmic solution 0.09 % in patients undergoing phacoemulsification. Patients requiring cataract extraction received one drop (50 µL) of bromfenac 0.09 % solution in the eye to be operated, before bedtime the day before surgery or the morning of the surgery. The last administration was recorded. At the time of paracentesis, an aqueous humor sample was collected with a 30-gauge needle attached to a TB syringe and was later analyzed by high-performance liquid chromatography for drug concentration. 188 treated volunteers and 48 control, untreated, subjects were included in the study. The mean aqueous concentration of bromfenac in the treated group was 37.60 ± 68.86 and 0 nM (nmol/L) in the control group (p < 0.0001). Correlation coefficient in bromfenac group between time elapsed from instillation and drug concentration was -0.16 (p not significant). Bromfenac showed properties of good penetration and stable concentration in aqueous humor up to about 12 h after instillation.

  20. Ligand adsorption on an activated carbon for the removal of chromate ions from aqueous solutions.

    Science.gov (United States)

    García-Martín, J; López-Garzón, R; Godino-Salido, M Luz; Gutiérrez-Valero, M Dolores; Arranz-Mascarós, P; Cuesta, R; Carrasco-Marín, F

    2005-07-19

    The results presented in this work are related to the design of a guideline to develop specific properties at the surface of an activated carbon (AC). For this, two model aromatic compounds have been synthesized and their electrolytic behavior in aqueous solutions was studied by a potentiometric method. The textural characteristics of the activated carbon were determined by porosimetry methods. The nature of oxygen-carrying functions and the acid-base behavior of the AC surface were characterized by TPD and potentiometric titration methods, respectively. The adsorption and desorption equilibria of the aromatic compounds on activated carbon were measured in aqueous solutions, and the hysteresis between adsorption and desorption, which reveals irreversible adsorption, was discussed on the basis of the frontier orbital theory. HOMO and LUMO orbitals of the adsorbent and adsorbates were calculated, and irreversible adsorption was attributed to the small energy difference between HOMO and LUMO of the aromatic adsorbates and the adsorbent. Adsorption equilibria of K2CrO4 in aqueous solution on the AC alone and on the AC-aromatic ligand adsorbents, respectively, prove the efficient development of specific chemical functions at the carbon surface provided by the adsorbed aromatic compounds.

  1. Radiation chemistry of aqueous solutions of acetonitrile and propionitrile

    International Nuclear Information System (INIS)

    Shushtarian, M.J.

    1975-01-01

    The radiation chemistry of water and aqueous solutions is a branch of radiation chemistry dealing with chemical changes in water and aqueous solutions induced by high energy radiations. High energy radiations of interest in radiation chemistry are short-wave electromagnetic radiations (X- and γ-rays) and fast charged particles (α- and β-particles, electrons, deuterons and fission fragments). The energy of the particles and photons bringing about chemical reactions in the field of modern radiation chemistry is much higher than that of photons causing photochemical reactions

  2. In situ observation of sol-gel transition of agarose aqueous solution by fluorescence measurement.

    Science.gov (United States)

    Wang, Zheng; Yang, Kun; Li, Haining; Yuan, Chaosheng; Zhu, Xiang; Huang, Haijun; Wang, Yongqiang; Su, Lei; Fang, Yapeng

    2018-06-01

    Sol-gel transition behavior of agarose aqueous solution was investigated by using rheology and fluorescence measurement. On heating, the storage modulus G' decreased gradually, then deviated abruptly at the temperature of about 65°C, and finally decreased slowly again. For fluorescence measurement, the phase transition point kept almost at the temperature of 65°C, which was consistent with that in rheology measurement. Upon compression, it was indicated that the fluorescence lifetime for the probe in the agarose aqueous solution showed a dramatic change in the vicinity of the phase transition point. T vs. P phase diagram of agarose aqueous solution was constructed, which showed that the melting point was an increasing function of pressure. Based on the phase diagram, the agarose gels were prepared by cooling under atmospheric pressure and the pressure of 300MPa, respectively. From the result of the recovered samples studied by optical rheometry, it was found that agarose gel prepared under high pressure had a higher elasticity and lower viscosity index, compared with that under atmospheric pressure. It could be speculated that such kinds of properties might be attributed to the smaller pore size during gelation under high pressure. Copyright © 2018. Published by Elsevier B.V.

  3. Radiolysis of Aqueous Toluene Solutions

    International Nuclear Information System (INIS)

    Christensen, H.C.; Gustafson, R.

    1971-04-01

    Aqueous toluene solutions have been irradiated with Co γ-rays. In unbuffered solutions the various cresol isomers are formed in a total yield of 0.45, 0.87 and 0.94 molecules/100 eV absorbed energy in argon-, N 2 O- and air - saturated solutions, respectively. The yields are reduced in acid (pH 3) solutions (G 0.14, 0.14 and 0.52, respectively) but the reduction is compensated by the formation of 1,2-di-phenylethane in yields of 0.49 and 1.60 in argon- and N 2 O-saturated solutions, respectively. Benzyl radicals are formed through an acid catalysed water elimination reaction from the initially formed hydroxymethylcyclohexadienyl radical. Phenyltolylmethanes, dimethylbiphenyls and partly reduced dimers are also formed during the radiolysis. Hydrogen is formed in the same yield as the molecular yield, g(H 2 ). Xylene isomers and benzene are formed in trace quantities. The most remarkable effects of the addition of Fe(III) ions to deaerated acid toluene solutions are the formation of benzyl alcohol and benzaldehyde and an increase in the yield of 1,2-diphenylethane

  4. Formation and transformations of radicals in frozen aqueous solutions of components of nucleic acids and H3PO4

    International Nuclear Information System (INIS)

    Minkhadzhidinova, D.R.; Chefranova, O.A.; Sharpatyj, V.A.

    1977-01-01

    Radiolysis of frozen aqueous solutions of 6-16 M H 3 PO 4 and 5 M NaH 2 PO 4 was studied, as well as radiolysis of these systems in the presence of nitrous bases and glucose. In aqueous solutions of H 3 PO 4 and NaH 2 PO 4 irradiated at 77 K, two groups of radicals formed as a result of interaction of the oxidative component of radiolysis of water with phosphate ions were identified. Their photolytic properties were studied. Primary products of radiolysis of the nitrous bases in phosphoric- acid solutions are anion- and cation-radicals. The molal absorption coefficients of the particles were determined

  5. Free radicals generated by radiolysis of aqueous solutions

    International Nuclear Information System (INIS)

    Schwarz, H.A.

    1981-01-01

    The free radicals produced in the radiolysis of aqueous solutions span the range of redox potentials from -2.9 to +2.65 volts. The identity and nature of these radicals were discussed. Most of the discussion was results obtained with low LET radiation sources ( 60 Co gamma radiation or electron accelerators). Water radiolysis provides the synthesis of many radicals and radical ions in aqueous solution. The primary radicals, e/sub aq/ - H, OH, are well characterized. The radical population can be made to be 90% pure OH (or O - ) if N 2 O solutions are irradiated, the remaining 10% being H atoms. 55% of the radicals can be converted to H atoms in acid solution or in neutral phosphate solutions(e/sub aq/ - reacts with H 2 PO 4- to produce H). The remaining 45% (OH radicals) are difficult to convert to H by reaction with H 2 , due to the slow rate of the reaction. About 100 atmospheres of H 2 are required to do the conversion in less than 10 - 6 sec. 3 figures, 3 tables. (DP)

  6. Hydrogen-bonded structure in highly concentrated aqueous LiBr solutions

    International Nuclear Information System (INIS)

    Imano, Masahiro; Kameda, Yasuo; Usuki, Takeshi; Uemura, Osamu

    2001-01-01

    Neutron diffraction measurements were carried out for H/D isotopically substituted aqueous 10, 25 and 33 mol% LiBr solutions in order to obtain structural information on the intermolecular hydrogen bonds among water molecules in highly concentrated aqueous solutions. Observed scattering cross sections for D 2 O (99.9 % D), 0 H 2 O(35.9 % D) and 0-2 H 2 O(68.0 % D) solutions were combined to deduce partial structure factors, a HH (Q), a XH (Q) and a XX (Q) (X: O, Br and Li). The least squares fitting analysis was applied to the observed partial structure factors to determine the nearest neighbor interatomic distance, root-mean-square amplitude and coordination number. Intermolecular distances, r OH =1.91(1) A, r HH =2.38(1) A and r OO =3.02(1) A, between the nearest neighbor water molecules, were obtained for the 10 mol% LiBr solution. On the other hand, the intermolecular O···H interaction was found to almost disappear in concentrated 25 and 33 mol% LiBr solutions. The result implies that the hydrogen-bonded network is completely broken in highly concentrated aqueous LiBr solutions. (author)

  7. Peroxide coordination of tellurium in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Mikhaylov, Alexey A.; Medvedev, Alexander G. [Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Moscow (Russian Federation); The Casali Center of Applied Chemistry, The Institute of Chemistry, The Hebrew University of Jerusalem (Israel); Churakov, Andrei V.; Grishanov, Dmitry A.; Prikhodchenko, Petr V. [Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Moscow (Russian Federation); Lev, Ovadia [The Casali Center of Applied Chemistry, The Institute of Chemistry, The Hebrew University of Jerusalem (Israel)

    2016-02-15

    Tellurium-peroxo complexes in aqueous solutions have never been reported. In this work, ammonium peroxotellurates (NH{sub 4}){sub 4}Te{sub 2}(μ-OO){sub 2}(μ-O)O{sub 4}(OH){sub 2} (1) and (NH{sub 4}){sub 5}Te{sub 2}(μ-OO){sub 2}(μ-O)O{sub 5}(OH).1.28 H{sub 2}O.0.72 H{sub 2}O{sub 2} (2) were isolated from 5 % hydrogen peroxide aqueous solutions of ammonium tellurate and characterized by single-crystal and powder X-ray diffraction analysis, by Raman spectroscopy and thermal analysis. The crystal structure of 1 comprises ammonium cations and a symmetric binuclear peroxotellurate anion [Te{sub 2}(μ-OO){sub 2}(μ-O)O{sub 4}(OH){sub 2}]{sup 4-}. The structure of 2 consists of an unsymmetrical [Te{sub 2}(μ-OO){sub 2}(μ-O)O{sub 5}(OH)]{sup 5-} anion, ammonium cations, hydrogen peroxide, and water. Peroxotellurate anions in both 1 and 2 contain a binuclear Te{sub 2}(μ-OO){sub 2}(μ-O) fragment with one μ-oxo- and two μ-peroxo bridging groups. {sup 125}Te NMR spectroscopic analysis shows that the peroxo bridged bitellurate anions are the dominant species in solution, with 3-40 %wt H{sub 2}O{sub 2} and for pH values above 9. DFT calculations of the peroxotellurate anion confirm its higher thermodynamic stability compared with those of the oxotellurate analogues. This is the first direct evidence for tellurium-peroxide coordination in any aqueous system and the first report of inorganic tellurium-peroxo complexes. General features common to all reported p-block element peroxides could be discerned by the characterization of aqueous and crystalline peroxotellurates. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Production of Plutonium Metal from Aqueous Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Orth, D.A.

    2003-01-16

    The primary separation of plutonium from irradiated uranium by the Purex solvent extraction process at the Savannah River Plant produces a dilute plutonium solution containing residual fission products and uranium. A cation exchange process is used for concentration and further decontamination of the plutonium, as the first step in the final preparation of metal. This paper discusses the production of plutonium metal from the aqueous solutions.

  9. Water Evaporation from Acoustically Levitated Aqueous Solution Droplets.

    Science.gov (United States)

    Combe, Nicole A; Donaldson, D James

    2017-09-28

    We present a systematic study of the effect of solutes on the evaporation rate of acoustically levitated aqueous solution droplets by suspending individual droplets in a zero-relative humidity environment and measuring their size as a function of time. The ratios of the early time evaporation rates of six simple salts (NaCl, NaBr, NaNO 3 , KCl, MgCl 2 , CaCl 2 ) and malonic acid to that of water are in excellent agreement with predictions made by modifying the Maxwell equation to include the time-dependent water activity of the evaporating aqueous salt solution droplets. However, the early time evaporation rates of three ammonium salt solutions (NH 4 Cl, NH 4 NO 3 , (NH 4 ) 2 SO 4 ) are not significantly different from the evaporation rate of pure water. This finding is in accord with a previous report that ammonium sulfate does not depress the evaporation rate of its solutions, despite reducing its water vapor pressure, perhaps due to specific surface effects. At longer evaporation times, as the droplets approach crystallization, all but one (MgCl 2 ) of the solution evaporation rates are well described by the modified Maxwell equation.

  10. Hemoglobin bioconjugates with surface-protected gold nanoparticles in aqueous media: The stability depends on solution pH and protein properties.

    Science.gov (United States)

    Del Caño, Rafael; Mateus, Lucia; Sánchez-Obrero, Guadalupe; Sevilla, José Manuel; Madueño, Rafael; Blázquez, Manuel; Pineda, Teresa

    2017-11-01

    The identification of the factors that dictate the formation and physicochemical properties of protein-nanomaterial bioconjugates are important to understand their behavior in biological systems. The present work deals with the formation and characterization of bioconjugates made of the protein hemoglobin (Hb) and gold nanoparticles (AuNP) capped with three different molecular layers (citrate anions (c), 6-mercaptopurine (MP) and ω-mercaptoundecanoic acid (MUA)). The main focus is on the behavior of the bioconjugates in aqueous buffered solutions in a wide pH range. The stability of the bioconjugates have been studied by UV-visible spectroscopy by following the changes in the localized surface resonance plasmon band (LSRP), Dynamic light scattering (DLS) and zeta-potential pH titrations. It has been found that they are stable in neutral and alkaline solutions and, at pH lower than the protein isoelectric point, aggregation takes place. Although the surface chemical properties of the AuNPs confer different properties in respect to colloidal stability, once the bioconjugates are formed their properties are dictated by the Hb protein corona. The protein secondary structure, as analyzed by Attenuated total reflectance infrared (ATR-IR) spectroscopy, seems to be maintained under the conditions of colloidal stability but some small changes in protein conformation take place when the bioconjugates aggregate. These findings highlight the importance to keep the protein structure upon interaction with nanomaterials to drive the stability of the bioconjugates. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. EXTRACTION OF MONOAZO DYES BY HYDROPHILIC EXTRACTANTS FROM AQUEOUS SOLUTIONS

    Directory of Open Access Journals (Sweden)

    Y. I. Korenman

    2012-01-01

    Full Text Available The extraction of mono azo dyes E102, E122, E110, E124, E129 from aqueous solutions with hydrophilic solvents (alcohols, esters, ketones and polymers (poly-N-vinylamides, polyethylene glycol was studied. The main regularities of extraction are established. The distribution coefficients and degree of extraction of dyes was estimate. The influence of the nature of solvents and polymers on the extraction of dyes from aqueous solutions are established.

  12. Fabrication of Amperometric Glucose Sensor Using Glucose Oxidase-Cellulose Nanofiber Aqueous Solution.

    Science.gov (United States)

    Yasuzawa, Mikito; Omura, Yuya; Hiura, Kentaro; Li, Jiang; Fuchiwaki, Yusuke; Tanaka, Masato

    2015-01-01

    Cellulose nanofiber aqueous solution, which remained virtually transparent for more than one week, was prepared by using the clear upper layer of diluted cellulose nanofiber solution produced by wet jet milling. Glucose oxidase (GOx) was easily dissolved in this solution and GOx-immobilized electrode was easily fabricated by simple repetitious drops of GOx-cellulose solution on the surface of a platinum-iridium electrode. Glucose sensor properties of the obtained electrodes were examined in phosphate buffer solution of pH 7.4 at 40°C. The obtained electrode provided a glucose sensor response with significantly high response speed and good linear relationship between glucose concentration and response current. After an initial decrease of response sensitivity for a few days, relatively constant sensitivity was obtained for about 20 days. Nevertheless, the influence of electroactive compounds such as ascorbic acid, uric acid and acetoaminophen were not negletable.

  13. Effect of sodium phosphate salts on the thermodynamic properties of aqueous solutions of poly(ethylene oxide) 6000 at different temperatures

    International Nuclear Information System (INIS)

    Sadeghi, Rahmat; Hosseini, Rahim; Jamehbozorg, Bahman

    2008-01-01

    Precise density, sound velocity, water activity, and phase diagram measurements have been carried out on polyethylene oxide (PEO) in aqueous solutions of sodium di-hydrogen phosphate, di-sodium hydrogen phosphate, and tri-sodium phosphate over a range of temperatures at atmospheric pressure. The experimental density and sound velocity data are used to calculate the apparent specific volume and isentropic compressibility as a function of temperature and concentration. It was found that both of the apparent specific volume and isentropic compressibility of PEO in aqueous solutions increase by increasing temperature and charge on the anion of electrolytes. The results show that the slope of constant water activity lines increased with increasing the temperature and charge on the anion of electrolytes and the vapour pressure depression for an aqueous (PEO + sodium phosphate) system is more than the sum of those for the corresponding binary solutions. Furthermore, the effect of temperature and type of anion of salt on the salting-out effect of polyethylene oxide by sodium phosphate salts has been studied

  14. Effect of sodium phosphate salts on the thermodynamic properties of aqueous solutions of poly(ethylene oxide) 6000 at different temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, Rahmat [Department of Chemistry, University of Kurdistan, Sanandaj (Iran, Islamic Republic of)], E-mail: rahsadeghi@yahoo.com; Hosseini, Rahim; Jamehbozorg, Bahman [Department of Chemistry, University of Kurdistan, Sanandaj (Iran, Islamic Republic of)

    2008-09-15

    Precise density, sound velocity, water activity, and phase diagram measurements have been carried out on polyethylene oxide (PEO) in aqueous solutions of sodium di-hydrogen phosphate, di-sodium hydrogen phosphate, and tri-sodium phosphate over a range of temperatures at atmospheric pressure. The experimental density and sound velocity data are used to calculate the apparent specific volume and isentropic compressibility as a function of temperature and concentration. It was found that both of the apparent specific volume and isentropic compressibility of PEO in aqueous solutions increase by increasing temperature and charge on the anion of electrolytes. The results show that the slope of constant water activity lines increased with increasing the temperature and charge on the anion of electrolytes and the vapour pressure depression for an aqueous (PEO + sodium phosphate) system is more than the sum of those for the corresponding binary solutions. Furthermore, the effect of temperature and type of anion of salt on the salting-out effect of polyethylene oxide by sodium phosphate salts has been studied.

  15. Recoil halogen reactions in liquid and frozen aqueous solutions of biomolecules

    International Nuclear Information System (INIS)

    Arsenault, L.J.; Blotcky, A.J.; Firouzbakht, M.L.; Rack, E.P.; Nebraska Univ., Omaha

    1982-01-01

    Reactions of recoil 38 Cl, 80 Br and 128 I have been studied in crystalline systems of 5-halouracil, 5-halo-2'-deoxyuridine and 5-halouridine as well as liquid and frozen aqueous solutions of these halogenated biomolecules. In all systems expect crystalline 5-iuodouracil the major product was the radio-labelled halide ion. There was no evidence for other halogen inorganic species. The major labelled organic product was the parent molecule. A recoil atom tracer technique was developed to acquire site information of the biomolecule solutes in the liquid and frozen aqueous systems. For all liquid and frozen aqueous systems, the halogenated biomolecules tended to aggregate. For liquid systems, the tendency for aggregation diminished as the solute concentration approached zero, where the probable state of the solute approached a monomolecular dispersion. Unlike the liquid state, the frozen ice lattice demonstated a ''caging effect'' for the solute aggregates which resulted in constant product yields over the whole concentration range. (orig.)

  16. γ-radiation induced tetracycline removal in an aqueous solution

    International Nuclear Information System (INIS)

    Zhou Fei; Guo Zhaobing; Zhang Chaozhi; Lin Mingyue; Wu Menglong; Zhao Yongfu

    2012-01-01

    Degradation effect of tetracycline (TC) by γ-radiation was investigated in an aqueous solution. The effects of initial concentrations of TC, pH values, combining with H 2 O 2 or CH 3 OH on degradation of TC were studied. Results showed that TC can be effectively degradated by γ-irradiation in an aqueous solution. Degradation of TC could be remarkably improved both in acid solution and alkaline solution, especially when pH value was 9.0. In addition, H 2 O 2 could gently promote degradation of TC induced by γ-radiation. While, CH 3 OH markedly restrained degradation of TC induced by γ-radiation. The degradation mechanism of TC was supposed by results of quantum chemical calculations and LC-MS. Results proved that degradation of TC induced by γ-radiation was mainly ascribed to · OH oxidation. (authors)

  17. Heavy metal removal from aqueous solutions by sorption using ...

    African Journals Online (AJOL)

    Heavy metal removal from aqueous solutions by sorption using natural clays from Burkina Faso. ... The high alkaline pH in one of the samples is attributable to the presence of ... The point of zero charge (pHpzc) values of the clays, as determined by ... significant contributions to the removal of metal ions in aqueous systems.

  18. Complex chemistry of Np(V) in aqueous solutions

    International Nuclear Information System (INIS)

    Inoue, Yasushi

    1989-01-01

    Despite the importance of Np(V) in both the nuclear chemical engineering and the actinoid chemistry, little work has been performed on the complex chemistry of Np(V) in aqueous solutions, since Np(V) reacts less readily with various ligands. The author has directed his effort to understand the chemical behavior of Np(V) in aqueous solutions, especially the determination of the stability constants of Np(V) complexes with various ligands. A part of the results obtained so far is presented in the following order. (1) The synergistic extraction of Np(V) as a method for studying the complex chemistry of Np(V): TTA-MTOA(methyltrioctylammonium chloride), TTA-phen and TTA-TOPO. (2) The determination of the stability constants of Np(V) complexes with 22 organic- and 5 inorganic ligands by means of the solvent extraction. (3) The distribution of the chemical species of Np(V) in solutions under various conditions

  19. Flotation separation of hafnium(IV) from aqueous solutions

    International Nuclear Information System (INIS)

    Downey, D.M.; Narick, C.N.; Cohen, T.A.

    1985-01-01

    A simple, rapid method for the separation of hafnium from aqueous solutions was investigated using sup(175+181)Hf tracer. Cationic hafnium complex ions were floated from dilute acid solutions with sodium lauryl sulfate (SLS) and anionic hafnium complexes were floated from basic and oxalic acid solutions with hexadecyltrimethyl ammonium bromide (HTMAB). The conditions necessary for quantitative recovery of the metal and mechanisms of flotation are described. (author)

  20. Treatment of infectious skin defects or ulcers with electrolyzed strong acid aqueous solution.

    Science.gov (United States)

    Sekiya, S; Ohmori, K; Harii, K

    1997-01-01

    A chronic ulcer with an infection such as methicillin-resistant Staphylococcus aureus is hard to heal. Plastic and reconstructive surgeons often encounter such chronic ulcers that are resistant to surgical or various conservative treatments. We applied conservative treatment using an electrolyzed strong acid aqueous solution and obtained satisfactory results. The lesion was washed with the solution or soaked in a bowl of the solution for approximately 20 min twice a day. Fresh electrolyzed strong acid aqueous solution is unstable and should be stored in a cool, dark site in a sealed bottle. It should be used within a week after it has been produced. Here we report on 15 cases of infectious ulcers that were treated by electrolyzed strong acid aqueous solution. Of these cases, 7 patients were healed, 3 were granulated, and in 5, infection subsided. In most cases the lesion became less reddish and less edematous. Discharge or foul odor from the lesion was decreased. Electrolyzed strong acid aqueous solution was especially effective for treating a chronic refractory ulcer combined with diabetes melitus or peripheral circulatory insufficiency. This clinically applied therapy of electrolyzed strong acid aqueous solution was found to be effective so that this new therapeutic technique for ulcer treatment can now be conveniently utilized.

  1. Radiolysis of Aqueous Toluene Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, H C; Gustafson, R

    1971-04-15

    Aqueous toluene solutions have been irradiated with Co gamma-rays. In unbuffered solutions the various cresol isomers are formed in a total yield of 0.45, 0.87 and 0.94 molecules/100 eV absorbed energy in argon-, N{sub 2}O- and air - saturated solutions, respectively. The yields are reduced in acid (pH 3) solutions (G = 0.14, 0.14 and 0.52, respectively) but the reduction is compensated by the formation of 1,2-di-phenylethane in yields of 0.49 and 1.60 in argon- and N{sub 2}O-saturated solutions, respectively. Benzyl radicals are formed through an acid catalysed water elimination reaction from the initially formed hydroxymethylcyclohexadienyl radical. Phenyltolylmethanes, dimethylbiphenyls and partly reduced dimers are also formed during the radiolysis. Hydrogen is formed in the same yield as the molecular yield, g(H{sub 2}). Xylene isomers and benzene are formed in trace quantities. The most remarkable effects of the addition of Fe(III) ions to deaerated acid toluene solutions are the formation of benzyl alcohol and benzaldehyde and an increase in the yield of 1,2-diphenylethane

  2. High-performance magnetic carbon materials in dye removal from aqueous solutions

    International Nuclear Information System (INIS)

    Gao, Xiaoming; Zhang, Yu; Dai, Yuan; Fu, Feng

    2016-01-01

    To obtain a novel adsorbent with excellent adsorption capacity and convenient magnetic separation property, magnetic activated semi-coke was prepared by KOH activation method and further modified by FeCl 3 . The surface morphology, physical structure, chemical properties and textural characteristics of unmodified semi-coke, KOH-modified semi-coke and magnetic activated semi-coke were characterized by scanning electron microscopy, X-ray powder diffraction, N 2 adsorption-desorption measurement, and electronic differential system. The adsorption characteristics of the magnetic activated semi-coke were explored for the removal of methyl orang (MO), methylene blue (MB), congo red (CR), acid fuchsin (AF), and rhodamine B (RB) from aqueous solution. The effects of adsorption parameters, including adsorbent dosage, pH and contact time, were investigated by comparing the adsorption properties of the magnetic activated semi-coke to RB. The result showed that the magnetic activated semi-coke displayed excellent dispersion, convenient separation and high adsorption capacity. The adsorption experiment data indicated that the pseudosecond order model and the Langmuir model could well explain the adsorption processes of RB on the magnetic activated semi-coke, and the maximum adsorption capacity (q m ) was 526.32 mg/g. The values of thermodynamic parameters (ΔG°, ΔH° and ΔS°) indicated that the adsorption process depended on the temperature of the aqueous phase, and it was spontaneous and exothermic in nature. As the addition of the magnetic activated semi-coke, the color of the solution significantly faded. Subsequently, fast aggregation of the magnetic activated semi-coke from their homogeneous dispersion in the presence of an external magnetic field could be happened. So, the magnetic activated semi-coke displayed excellent dispersion, convenient separation and high adsorption capacity. - Graphical abstract: As the addition of the magnetic activated semi-coke, the color

  3. Effects of Radiosterilization on Sealed Aqueous Solutions

    International Nuclear Information System (INIS)

    Pandula, E.L.; Farkas, E.; Rácz, I.

    1967-01-01

    For aqueous solutions sensitive to heat,and in connection with the use of plastic ampoules, the need for applying radiosterilization is growing. Studying the possibilities of radiosterilization, experiments were made with the following: 0.1% atropine, 1.0% morphine, and 2% lidocain in aqueous solutions. The aim of the work was to establish whether the active ingredients of the injections suffer decomposition or not, to study the factors influencing the degradation and, furthermore, to make attempts to prevent decomposition. The samples were irradiated by 420 Ci 60 Co γ-radiation source. The applied doses were 1 to 2.5 Mrad, with a 10 4 to 2.5 x 10 5 rad/h dose intensity. After irradiation the change in colour, pH-value, concentration and UV-spectra were studied. Changes of the last three types were found. Studying the factors influencing decomposition it has been found that the degree of degradation was increased by the increase of radiation dose, increase of concentration, decrease of dose intensity, and increase of oxygen content in the atmosphere over the solution. Attempts were made to prevent degradation. Solutions were prepared with sulphite, ascorbic acid, and AET, and some measure of success was achieved, especially with the sulphite addition. (author)

  4. GEOSURF: a computer program for modeling adsorption on mineral surfaces from aqueous solution

    Science.gov (United States)

    Sahai, Nita; Sverjensky, Dimitri A.

    1998-11-01

    A new program, GEOSURF, has been developed for calculating aqueous and surface speciation consistent with the triple-layer model of surface complexation. GEOSURF is an extension of the original programs MINEQL, MICROQL and HYDRAQL. We present, here, the basic algorithm of GEOSURF along with a description of the new features implemented. GEOSURF is linked to internally consistent data bases for surface species (SURFK.DAT) and for aqueous species (AQSOL.DAT). SURFK.DAT contains properties of minerals such as site densities, and equilibrium constants for adsorption of aqueous protons and electrolyte ions on a variety of oxides and hydroxides. The Helgeson, Kirkham and Flowers version of the extended Debye-Huckel Equation for 1:1 electrolytes is implemented for calculating aqueous activity coefficients. This permits the calculation of speciation at ionic strengths greater than 0.5 M. The activity of water is computed explicitly from the osmotic coefficient of the solution, and the total amount of electrolyte cation (or anion) is adjusted to satisfy the electroneutrality condition. Finally, the use of standard symbols for chemical species rather than species identification numbers is included to facilitate use of the program. One of the main limitations of GEOSURF is that aqueous and surface speciation can only be calculated at fixed pH and at fixed concentration of total adsorbate. Thus, the program cannot perform reaction-path calculations: it cannot determine whether or not a solution is over- or under-saturated with respect to one or more solid phases. To check the proper running of GEOSURF, we have compared results generated by GEOSURF with those from two other programs, HYDRAQL and EQ3. The Davies equation and the "bdot" equation, respectively, are used in the latter two programs for calculating aqueous activity coefficients. An example of the model fit to experimental data for rutile in 0.001 M-2.0 M NaNO 3 is included.

  5. Measuring and modeling aqueous electrolyte/amino-acid solutions with ePC-SAFT

    International Nuclear Information System (INIS)

    Held, Christoph; Reschke, Thomas; Müller, Rainer; Kunz, Werner; Sadowski, Gabriele

    2014-01-01

    Highlights: • Amino-acid solubilities and osmotic coefficients in ternary solutions containing one amino acids and one salt measured. • Weak salt influence on amino-acid solubilities except for salts containing Mg [2+] or NO 3 [−] (salting-in behavior). • Osmotic coefficients dominated by the solute with the highest molality. • Amino-acid solubilities and osmotic coefficients predicted reasonably with ePC-SAFT with deviations of 3.7% and 9.3%. • Predictions based on pure-component parameters for ions and amino acids using no ion/amino-acid fitting parameters. -- Abstract: In this work thermodynamic properties of electrolyte/amino acid/water solutions were measured and modeled. Osmotic coefficients at 298.15 K were measured by means of vapor-pressure osmometry. Amino-acid solubility at 298.15 K was determined gravimetrically. Considered aqueous systems contained one of the four amino acids: glycine, L-/DL-alanine, L-/DL-valine, and L-proline up to the respective amino-acid solubility limit and one of 13 salts composed of the ions Li + , Na + , K + , NH 4 + , Cl − , Br − , I − , NO 3 − , and SO 4 2− at salt molalities of 0.5, 1.0, and 3.0 mol · kg −1 , respectively. The data show that the salt influence is more pronounced on osmotic coefficients than on amino-acid solubility. The electrolyte Perturbed-Chain Statistical Association Theory (ePC-SAFT) was applied to model thermodynamic properties in aqueous electrolyte/amino-acid solutions. In previous works, this model had been applied to binary salt/water and binary amino acid/water systems. Without fitting any additional parameters, osmotic coefficients and amino-acid solubility in the ternary electrolyte/amino acid/water systems could be predicted with overall deviations of 3.7% and 9.3%, respectively, compared to the experimental data

  6. Benzimidazole acrylonitriles as multifunctional push-pull chromophores: Spectral characterisation, protonation equilibria and nanoaggregation in aqueous solutions

    Science.gov (United States)

    Horak, Ema; Vianello, Robert; Hranjec, Marijana; Krištafor, Svjetlana; Zamola, Grace Karminski; Steinberg, Ivana Murković

    2017-05-01

    Heterocyclic donor-π-acceptor molecular systems based on an N,N-dimethylamino phenylacrylonitrile benzimidazole skeleton have been characterised and are proposed for potential use in sensing applications. The benzimidazole moiety introduces a broad spectrum of useful multifunctional properties to the system including electron accepting ability, pH sensitivity and compatibility with biomolecules. The photophysical characterisation of the prototropic forms of these chromophores has been carried out in both solution and on immobilisation in polymer films. The experimental results are further supported by computational determination of pKa values. It is noticed that compound 3 forms nanoaggregates in aqueous solutions with aggregation-induced emission (AIE) at 600 nm. All the systems demonstrate spectral pH sensitivity in acidic media which shifts towards near-neutral values upon immobilisation in polymer films or upon aggregation in an aqueous environment (compound 3). The structure-property relationships of these functional chromophores, involving their spectral characteristics, acid-base equilibria, pKa values and aggregation effects have been determined. Potential applications of the molecules as pH and biomolecular sensors are proposed based on their pH sensitivity and AIE properties.

  7. Uranyl fluoride luminescence in acidic aqueous solutions

    International Nuclear Information System (INIS)

    Beitz, J.V.; Williams, C.W.

    1996-01-01

    Luminescence emission spectra and decay rates are reported for uranyl species in acidic aqueous solutions containing HF or added NaF. The longest luminescence lifetime, 0.269 ± 0.006 ms, was observed from uranyl in 1 M HF + 1 M HClO 4 at 296 K and decreased with increasing temperature. Based on a luminescence dynamics model that assumes equilibrium among electronically excited uranyl fluoride species and free fluoride ion, this long lived uranyl luminescence in aqueous solution is attributed primarily to UO 2 F 2 . Studies on the effect of added LiNO 3 or Na 2 WO 4 ·2H 2 O showed relatively weak quenching of uranyl fluoride luminescence which suggests that high sensitivity determination of the UF 6 content of WF 6 gas should be feasible via uranyl luminescence analysis of hydrolyzed gas samples of impure WF 6

  8. The effect of physiologic aqueous solutions on the perovskite material lead-lanthanum-zirconium titanate (PLZT): potential retinotoxicity.

    Science.gov (United States)

    Foster, William J; Meen, James K; Fox, Donald A

    2013-03-01

    Perovskite compounds, including lead-lanthanum-zirconium titanate (PLZT), have wide technological application because of their unique physical properties. The use of PLZT in neuro-prosthetic systems, such as retinal implants, has been discussed in a number of publications. Since inorganic lead is a retinotoxic compound that produces retinal degeneration, the long-term stability of PLZT in aqueous biological solutions must be determined. We evaluated the stability and effects of prolonged immersion of a PLZT-coated crystal in a buffered balanced salt solution. Scanning Electron Microscopy and Electron Dispersive Spectroscopy (EDS) using a JEOL JSM 5410 microscope equipped with EDS were utilized to evaluate the samples before and after prolonged immersion. We found that lead and other constituents of PLZT leached into the surrounding aqueous medium. By comparing the unit cell of PLZT with that of CaTiO(3), which has been found to react with aqueous fluids, Lead is in the same site in PLZT as Ca is in CaTiO(3). It is thus reasonable that PLZT will react with aqueous solutions. The results suggest that PLZT must either be coated with a protective layer or is not appropriate for long-term in vivo or in vitro biological applications.

  9. Properties of aqueous dispersion of chitosan and chondroitin sulfate complex derived from aquatic organisms

    Directory of Open Access Journals (Sweden)

    Novikov V. Yu.

    2016-09-01

    Full Text Available Investigation of production of chondroitin sulfate, chitosan and polyelectrolyte complexes based on them received from the local marine raw materials is relevant from the point of view of developing a comprehensive waste-free technology for natural raw materials processing. The objects of study are chitosan derived from the shell of the Kamchatka crab Paralithodes camtschaticus and chondroitin sulfate derived from cartilage of salmon Salmon salar. To determine the surface tension of polyelectrolyte complex solutions and dispersions the Wilhelmy method has been used, the effective radius of particle dispersion has been calculated by light scattering, measurements of effective viscosity have been carried out under shear deformation. The conditions of formation, surface and rheological properties of the chitosan and chondroitin sulfate complex extracted from aquatic organisms in the Barents Sea have been studied. Obtaining conditions and molar ratios of these polyelectrolytes in which the aqueous dispersion of the complex remains stable for a long time have been established. It has been found that by addition of chondroitin sulfate solution to chitosan solution in molar ratios of 1 : 3; 1 : 6 the dispersion of the polyelectrolyte complex stable for 2 to 3 days has been formed. The polyelectrolyte complex dispersions behave as non-Newtonian pseudoplastic liquid. When the molar ratio of the mixed solution is 1 : 1 (regardless of the sequence of mixing suspension of the polyelectrolyte complex has been formed, then there is precipitation. Equilibrium surface tension of the aqueous dispersion of the polyelectrolyte complex is higher than that of solutions of chondroitin sulfate and chitosan. The effective radius of particles in the complex dispersion has been determined. The effective radius of the particles in the complex dispersion depends on the molar ratio of chondroitin sulfate : chitosan. A qualitative scheme of formation of polyelectrolyte

  10. Surface tension and related thermodynamic quantities of aqueous electrolyte solutions

    CERN Document Server

    Matubayasi, Norihiro

    2013-01-01

    Surface tension provides a thermodynamic avenue for analyzing systems in equilibrium and formulating phenomenological explanations for the behavior of constituent molecules in the surface region. While there are extensive experimental observations and established ideas regarding desorption of ions from the surfaces of aqueous salt solutions, a more successful discussion of the theory has recently emerged, which allows the quantitative calculation of the distribution of ions in the surface region. Surface Tension and Related Thermodynamic Quantities of Aqueous Electrolyte Solutions provides a d

  11. Adsorption of lead from aqueous solutions by poly (methyl methacrylate)

    International Nuclear Information System (INIS)

    Din, M.; Hussain, R.

    1992-01-01

    The adsorption capability of commercially manufactured poly (methyl methacrylate) for lead in aqueous medium has been investigated. Percent adsorption and distribution coefficient values have been determined in relation to the shaking time, amount of adsorbent, pH effects and concentration of lead in the solution. The experimental results are compatible with Freundlich type of adsorption behavior. It is discernible from the experimental results that poly (methyl methacrylate) can be used for the removal of lead from slightly acidic aqueous solutions. (author)

  12. Removal of dexamethasone from aqueous solution and hospital wastewater by electrocoagulation

    International Nuclear Information System (INIS)

    Arsand, Daniel R.; Kümmerer, Klaus; Martins, Ayrton F.

    2013-01-01

    This study is concerned with the removal of the anti-inflammatory dexamethasone from aqueous solution and hospital wastewater by electrocoagulation. The variation of the toxicity during the electrocoagulation was also studied through experiments that were designed and optimized by means of response surface methodology. The coagulation efficiency was evaluated by measuring the dexamethasone concentration by high performance liquid chromatography coupled to a diode array detector. In addition, variation was evaluated through a Vibrio fischeri test. The results showed an increase in the removal of dexamethasone (up to 38.1%) with a rise of the current applied and a decrease of the inter-electrode distance, in aqueous solutions. The application to hospital effluent showed similar results for the removal of dexamethasone. The main effect of the electrocoagulation was that it removed colloids and reduced the organic load of the hospital wastewater. Regarding the current applied, the calculated energy efficiency was 100%. Without pH adjustment of the aqueous solution or hospital wastewater, the residual aluminum concentration always remained lower than 10 mg L −1 , and, with adjustment (to pH 6.5), lower than 0.30 mg L −1 , at the final stage. No toxicity variation was observed during the electrocoagulation process in aqueous solution, either in the presence or absence of dexamethasone. - Highlights: ► Removal of DEX and organic load from aqueous solution and hospital wastewater by EC ► Evaluation of the toxicity during the removal of DEX by EC ► Suggestion of the EC process as a pretreatment for subsequent processes

  13. Removal of dexamethasone from aqueous solution and hospital wastewater by electrocoagulation

    Energy Technology Data Exchange (ETDEWEB)

    Arsand, Daniel R., E-mail: danielarsand@pelotas.ifsul.edu.br [Chemistry Department, Federal University of Santa Maria, RS (Brazil); Kümmerer, Klaus, E-mail: klaus.kuemmerer@leuphana.de [Institute for Environmental Chemistry, Leuphana University Lüneburg (Germany); Martins, Ayrton F., E-mail: martins@quimica.ufsm.br [Chemistry Department, Federal University of Santa Maria, RS (Brazil)

    2013-01-15

    This study is concerned with the removal of the anti-inflammatory dexamethasone from aqueous solution and hospital wastewater by electrocoagulation. The variation of the toxicity during the electrocoagulation was also studied through experiments that were designed and optimized by means of response surface methodology. The coagulation efficiency was evaluated by measuring the dexamethasone concentration by high performance liquid chromatography coupled to a diode array detector. In addition, variation was evaluated through a Vibrio fischeri test. The results showed an increase in the removal of dexamethasone (up to 38.1%) with a rise of the current applied and a decrease of the inter-electrode distance, in aqueous solutions. The application to hospital effluent showed similar results for the removal of dexamethasone. The main effect of the electrocoagulation was that it removed colloids and reduced the organic load of the hospital wastewater. Regarding the current applied, the calculated energy efficiency was 100%. Without pH adjustment of the aqueous solution or hospital wastewater, the residual aluminum concentration always remained lower than 10 mg L{sup −1}, and, with adjustment (to pH 6.5), lower than 0.30 mg L{sup −1}, at the final stage. No toxicity variation was observed during the electrocoagulation process in aqueous solution, either in the presence or absence of dexamethasone. - Highlights: ► Removal of DEX and organic load from aqueous solution and hospital wastewater by EC ► Evaluation of the toxicity during the removal of DEX by EC ► Suggestion of the EC process as a pretreatment for subsequent processes.

  14. Flotation separation of hafnium(IV) from aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Downey, D.M.; Narick, C.N.; Cohen, T.A.

    1985-09-01

    A simple, rapid method for the separation of hafnium from aqueous solutions was investigated using sup(175 + 181)Hf tracer. Cationic hafnium complex ions were floated from dilute acid solutions with sodium lauryl sulfate (SLS) and anionic hafnium complexes were floated from basic and oxalic acid solutions with hexadecyltrimethyl ammonium bromide (HTMAB). The conditions necessary for quantitative recovery of the metal and mechanisms of flotation are described. (author). 21 refs.; 5 figs.

  15. On NO3-H2O interactions in aqueous solutions and at interfaces

    International Nuclear Information System (INIS)

    Dang, Liem X.; Chang, Tsun-Mei; Roeselova, Martina; Garrett, Bruce C.; Tobias, Douglas J.

    2006-01-01

    Constrained molecular dynamics technique was employed to investigate the transport of a nitrate ion across the water liquid/vapor interface. We developed the nitrate ion-water polarizable potential capable of describing well the solvation properties of the hydrated nitrate ion. The computed free energy profile for the transfer of the nitrate ion across the air/water interface increases monotonically as the nitrate ion approaches the Gibbs dividing surface from the bulk liquid side. The computed density profiles of 1M KNO3 salt solution slab indicate that the nitrate and potassium ions are both found below the aqueous interface. Upon analyzing the results, we can conclude that the probability of finding the nitrate anion at the aqueous interface is quite small

  16. Preparation and characterization of novel PVDF nanofiltration membranes with hydrophilic property for filtration of dye aqueous solution

    Science.gov (United States)

    Nikooe, Naeme; Saljoughi, Ehsan

    2017-08-01

    In the present research, for the first time PVDF/Brij-58 blend nanofiltration membranes with remarkable performance in filtration of dye aqueous solution were prepared via immersion precipitation. A noticeable improvement in water permeation and fouling resistance of the PVDF membranes was achieved by using Brij-58 surfactant as a hydrophilic additive. Scanning electron microscopy (SEM), fourier transform infrared spectroscopy (FT-IR) and water contact angle were applied for the investigation of membrane morphology, detection of the surface chemical composition and relative hydrophilicity/hydrophobicity, respectively. The membrane performance was studied and compared by determination of pure water flux (PWF) and filtration of synthetic reactive dye aqueous solutions as well as bovine serum albumin (BSA) as foulant model. It was found out that addition of 4 wt.% Brij-58 to the casting solution results in formation of membrane with remarkable hydrophilicity and fouling resistance (contact angle of 46° and flux recovery ratio (FRR) = 90%), higher porosity and consequently noticeable PWF (31.2 L/m2 h) and recognized dye rejection value (90%) in comparison with the pristine PVDF nanofiltration membrane. Addition of Brij-58 surfactant to the casting solution resulted in formation of NF membrane with higher hydrophilicity and permeability as well as higher dye rejection value in comparison with the addition of PEG 400 additive.

  17. Spinning of Fibers from Aqueous Solutions

    Science.gov (United States)

    2003-08-01

    recombinant silk product BioSteel . Publications, patents and presentations 1. Arcidiacono, S., et al., Purification and characterization of recombinant...ABSTRACT Previous funding supporting this research focused primarily on development of the aqueous-based method for processing silk into spin solutions. Much...of this effort consisted of production of recombinant silk protein in bacterial and yeast expression systems. In spite of the small quantities

  18. In Situ Structural Characterization of Ferric Iron Dimers in Aqueous Solutions

    DEFF Research Database (Denmark)

    Zhu, Mengqiang; Puls, Brendan W.; Frandsen, Cathrine

    2013-01-01

    The structure of ferric iron (Fe3+) dimers in aqueous solutions has long been debated. In this work, we have determined the dimer structure in situ in aqueous solutions using extended X-ray absorption fine structure (EXAFS) spectroscopy. An Fe K-edge EXAFS analysis of 0.2 M ferric nitrate solutions...... at pH 1.28–1.81 identified a Fe–Fe distance at ∼3.6 Å, strongly indicating that the dimers take the μ-oxo form. The EXAFS analysis also indicates two short Fe–O bonds at ∼1.80 Å and ten long Fe–O bonds at ∼2.08 Å, consistent with the μ-oxo dimer structure. The scattering from the Fe–Fe paths interferes...... confirmed by Mössbauer analyses of analogous quick frozen solutions. This work also explores the electronic structure and the relative stability of the μ-oxo dimer in a comparison to the dihydroxo dimer using density function theory (DFT) calculations. The identification of such dimers in aqueous solutions...

  19. Thermochemical study of aqueous solutions of lithium diclofenac at 293.15-318.15 K

    Science.gov (United States)

    Manin, N. G.; Perlovich, G. L.; Fini, A.

    2013-04-01

    The enthalpies of solution and dilution of aqueous solutions of lithium diclofenac (LiDC) are measured in the concentration range of 0.002-0.047 m at 293.15, 298.15, 308.15, and 318.5 K using an isoperibolic calorimeter. The heat capacity of solid LiDC in the temperature range of 273.15-373.15 K is determined using a DSC 204 F1 Phoenix differential scanning calorimeter (NETZSCH, Germany). The virial coefficients of the enthalpy characteristics of a water-LiDC solution are derived in terms of the Pitzer model to calculate a wide range of thermodynamic properties of both the solution and its components. Changes in these characteristics as a function of concentration and temperature are discussed.

  20. Photoproduction of hydroxyl radicals in aqueous solution with algae under high-pressure mercury lamp.

    Science.gov (United States)

    Liu, Xianli; Wu, Feng; Deng, Nansheng

    2004-01-01

    Photoproduction of hydroxyl radicals (*OH) could be induced in aqueous solution with algae (Nitzschia hantzschiana, etc.) and (or not) Fe3+ under high-pressure mercury lamp with an exposure time of 4 h. *OH was determined by HPLC using benzene as a probe. The photoproduction of *OH increased with increasing algae concentration. Fe3+ could enhance the photoproduction of *OH in aqueous solution with algae. The results showed that the photoproduction of *OH in algal solution with Fe3+ was greater than that in algal solution without Fe3+. The light intensity and pH affected the photoproduction of *OH in aqueous solution with algae with/without Fe3+. The photoproduction of *OH in aqueous solution with algae and Fe3+ under 250 W was greater than that under 125 W HPML. The photoproduction of *OH in algal solution (pH ranged from 4.0 to 7.0) with (or not) Fe3+ at pH 4 was the greatest.

  1. Pulse radiolysis of anthraquinone dye aqueous solution

    International Nuclear Information System (INIS)

    Perkowski, J.; Gebicki, J.L.; Lubis, R.; Mayer, J.

    1988-01-01

    Pulse radiolysis of argon flushed aqueous solutions of 10 -5 -10 -4 mol dm -3 anthraquinone dye (C.I. Acid Blue 62) gives rise to the transients originated from the reactions of e - aq , OH and H. The rate constants of these reactions are determined. (author)

  2. Separation of Co2+ present in aqueous solution on calcium carbonate

    International Nuclear Information System (INIS)

    Garcia A, E.; Granados C, F.

    2008-01-01

    The CaCO 3 was synthesized by precipitation method and characterized using SEM, EDS, TGA and IR. It was studied the adsorption behavior of Co 2+ present in aqueous solution on the synthesized material by experiments batch type at room temperature. Was found that removal of cobalt ions was greater than 40% indicating that this material can be used to remove Co 2+ present in aqueous solution. (Author)

  3. Uranium in aqueous solutions by colorimetry

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The method covers the quantitative determination of uranium in known volumes of aqueous solutions that contain radioactive nuclides. These solutions arise from processing of irradiated nuclear fuel and from laboratory studies on irradiated uranium. The method is applicable to solutions containing a minimum of 30 μg of uranium per sample although as little as 0.5 μg can be detected but with lower precision. Highest precision is obtained with 50 to 75 μg of uranium in the test sample. Dilutions must be made at concentrations above 750 μg/ml. The method includes a discussion of photometers and photometric practice, apparatus, reagents, cell matching, preparation of standard curves, calibration by the method of internal standards, procedure, calculation, and precision

  4. Enthalpies of dilution of aqueous Li{sub 2}B{sub 4}O{sub 7} solutions at 298.15K and application of ion-interaction model

    Energy Technology Data Exchange (ETDEWEB)

    Yin Guoyin [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China); Graduate School of Chinese Academy of Sciences, Beijing 100039 (China); Yao Yan [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China) and Graduate School of Chinese Academy of Sciences, Beijing 100039 (China)]. E-mail: yaoy@isl.ac.cn; Jiao Baojuan [Department of Chemistry, Northwest University, Xi' an 710069 (China); Chen Sanping [Department of Chemistry, Northwest University, Xi' an 710069 (China); Gao Shengli [Department of Chemistry, Northwest University, Xi' an 710069 (China)

    2005-09-15

    The enthalpies of dilution have been measured for aqueous Li{sub 2}B{sub 4}O{sub 7} solutions from 0.0212 to 2.1530molkg{sup -1} at 298.15K. The relative apparent molar enthalpies, L{sub {phi}}, and relative partial molar enthalpies of the solvent and solute, L-bar{sub 1} and L-bar{sub 2} were calculated. The thermodynamic properties of the complex aqueous solutions were represented with a modified Pitzer ion-interaction model.

  5. Acoustic and volumetric properties of betaine hydrochloride drug in aqueous D(+)-glucose and sucrose solutions

    International Nuclear Information System (INIS)

    Ryshetti, Suresh; Gupta, Akash; Tangeda, Savitha Jyostna; Gardas, Ramesh L.

    2014-01-01

    Highlights: • Density and speed of sound are measured for B.HCl drug in aq. D(+)-glucose and sucrose. • Solvation behavior of B.HCl drug studied in aqueous D(+)-glucose and sucrose. • Cosphere overlap model is used to understand the transfer partial molar volume. • Hepler’s constant indicated structure making ability of B.HCl drug in studied systems. - Abstract: The densities (ρ) and speeds of sound (u) of betaine hydrochloride (B.HCl) drug (0.01 to 0.06) mol · kg −1 in (0.10, 0.20 and 0.30) mol · kg −1 aqueous D(+)-glucose and sucrose solutions are reported as a function of temperature at T = (293.15 to 313.15) K and atmospheric pressure. The values of density (ρ) and speed of sound (u) are obtained with high precision. These values have been used to estimate the apparent molar volume (V 2,ϕ ), partial molar volume (V 2 ∞ ), transfer partial molar volume (Δ t V 2 ∞ ), apparent molar isentropic compressibility (K s,2,ϕ ), partial molar isentropic compressibility (K s,2 ∞ ), transfer partial molar compressibility (Δ t K s,2 ∞ ), hydration number (N H ), partial molar expansion (E 2 ∞ ) and Hepler’s constant (∂ 2 V 2 ∞ /∂T 2 ) P . Furthermore, pair (V AB and K AB ) and triplet (V ABB and K ABB ) interaction coefficients have been computed from the values of Δ t V 2 ∞ and Δ t K s,2 ∞ . The co-sphere overlap model is used to understand the values of Δ t V 2 ∞ and Δ t K s,2 ∞ . The positive values of (∂ 2 V 2 ∞ /∂T 2 ) P indicate structure making ability of betaine hydrochloride in aqueous D(+)-glucose and sucrose solutions at the temperatures and compositions investigated

  6. Adsorption properties of Congo Red from aqueous solution onto surfactant-modified montmorillonite

    International Nuclear Information System (INIS)

    Wang Li; Wang Aiqin

    2008-01-01

    A series of surfactant-modified montmorillonites (MMT) were prepared using octyltrimethylammonium bromide (OTAB), dodecyltrimethylammonium bromide (DTAB), cetyltrimethylammonium bromide (CTAB) and stearyltrimethylammonium bromide (STAB), and the organification of MMT was proved by Fourier transform infrared (FTIR) spectroscopy, X-ray diffraction (XRD), scanning electron micrographic (SEM) and transmission electron microscope (TEM). The adsorption of Congo Red (CR) anionic dye from aqueous solution onto surfactant-modified MMT was carried out. Compared with MMT, the adsorption capacity of surfactant-modified MMT for CR was greatly enhanced and MMT modified with CTAB (2.0 CEC) exhibited the higher adsorption capacity. The effects of pH value of the dye solution, adsorption temperature, adsorption time and the initial dye concentration on the adsorption capacity of CR on CTAB-MMT have been investigated. The results showed that the adsorption kinetic of CR on CTAB-MMT could be best described by the pseudo-second-order model and that the adsorption isotherm of CR was in good agreement with the Langmuir equation. The IR spectra and SEM analysis also revealed that the adsorption of CTAB-MMT was a chemical adsorption process between CTAB and the NH 2 , -N=N- and SO 3 groups of CR

  7. Effect of acidic aqueous solution on chemical and physical properties of polyamide NF membranes

    Science.gov (United States)

    Jun, Byung-Moon; Kim, Su Hwan; Kwak, Sang Kyu; Kwon, Young-Nam

    2018-06-01

    This work was systematically investigated the effects of acidic aqueous solution (15 wt% sulfuric acid as model wastewater from smelting process) on the physical and chemical properties of commercially available nanofiltration (NF) polyamide membranes, using piperazine (PIP)-based NE40/70 membranes and m-phenylene diamine (MPD)-based NE90 membrane. Surface properties of the membranes were studied before and after exposure to strong acid using various analytical tools: Scanning Electron Microscopy (SEM), Attenuated Total Reflectance-Fourier Transform Infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS), contact angle analyzer, and electrophoretic light scattering spectrophotometer. The characterization and permeation results showed piperazine-based NE40/70 membranes have relatively lower acid-resistance than MPD-based NE90 membrane. Furthermore, density functional theory (DFT) calculation was also conducted to reveal the different acid-tolerances between the piperazine-based and MPD-based polyamide membranes. The easiest protonation was found to be the protonation of oxygen in piperazine-based monomer, and the N-protonation of the monomer had the lowest energy barrier in the rate determining step (RDS). The calculations were well compatible with the surface characterization results. In addition, the energy barrier in RDS is highly correlated with the twist angle (τD), which determines the delocalization of electrons between the carbonyl πCO bond and nitrogen lone pair, and the tendency of the twist angle was also maintained in longer molecules (dimer and trimer). This study clearly explained why the semi-aromatic membrane (NE40/70) is chemically less stable than the aromatic membrane (NE90) given the surface characterizations and DFT calculation results.

  8. Adsorption of Polycyclic Aromatic Hydrocarbons (PAHS from Aqueous Solutions on Different Sorbents

    Directory of Open Access Journals (Sweden)

    Smol Marzena

    2014-12-01

    Full Text Available This paper presents the results of the possibility and effectiveness of PAHs removal from a model aqueous solution, during the sorption on the selected sorbents. Six PAHs (naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene listed by EPA for the analysis in the environmental samples were determined. Model aqueous solution was prepared with RESTEK 610 mix PAHs standard. After the sorption process, decrease in the concentration of individual hydrocarbons was observed. The removal percentage was dependent on the type of sorbent (quartz sand, mineral sorbent, activated carbon. The highest efficiency (98.1% was observed for activated carbon.. The results shows that the sorption processes can be used in aqueous solutions treatment procedures.

  9. Application of Activated Carbon for Removal of Arsenic Ions from Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    R. Ansari

    2007-01-01

    Full Text Available The activated carbon (AC was used for removal of As(III and As(V ions from aqueous solutions. Sorption experiments were conducted using both batch and column systems. The effect of some important parameters on sorption of these by AC was studied. It was found that among the different factors affecting sorption capacity and efficiency in removal of arsenic from aqueous solutions, the effect of pH and the oxidation state were the most prominent. The optimum pH values for removal of As(III and As(V from aqueous solutions using AC was found 12 and 3 respectively. Impregnation of AC with sulphur contain organic dyes, it is possible to improve As(III uptake considerably.

  10. Molybdenum: the element and aqueous solution chemistry

    International Nuclear Information System (INIS)

    Sykes, A.G.

    1987-01-01

    This chapter on the chemistry of the coordination compounds of molybdenum concentrates on the element itself, its recovery from ores and its use in the manufacture of steels. Most of the chapter is devoted to the aqueous solution chemistry of molybdenum in oxidation states II, III and IV. (UK)

  11. Sorption of Pb2+ from Aqueous Solution unto Modified Rice Husk: Isotherms Studies

    Directory of Open Access Journals (Sweden)

    A. O. Dada

    2013-01-01

    Full Text Available Investigation of the sorption potential of rice husk, an agricultural waste, as an adsorbent was carried out. The rice husk was modified with orthophosphoric acid and was used for adsorption of lead (II ions (Pb2+ from aqueous solution. Physicochemical properties of the modified rice husk were determined. Equilibrium sorption data were confirmed with Langmuir, Freundlich and Temkin adsorption isotherms. On the basis of adsorption isotherm graphs, R2 values were determined to be 0.995, 0.916, and 0.797 for Langmuir, Temkin, and Freundlich isotherms, respectively, indicating that the data fitted well into the adsorption isotherms, but Langmuir isotherm is a better model. The maximum monolayer coverage from Langmuir studies, Qmax=138.89 mg/g, Langmuir isotherm constant, KL=0.699 L/mg, and the separation factor, RL=1.41×10−2 at 100 mg/L of lead(II ions indicating that the sorption process, was favourable. The suitability of modified rice husk as an adsorbent for the removal of lead ions from aqueous solution and its potential for pollution control is established.

  12. Synthesis of sub-millimeter calcite from aqueous solution

    Science.gov (United States)

    Reimi, M. A.; Morrison, J. M.; Burns, P. C.

    2011-12-01

    A novel aqueous synthesis that leads to the formation of calcite (CaCO3) crystals, up to 500μm in diameter, will be used to facilitate the study of contaminant transport in aqueous environmental systems. Existing processes tend to be complicated and often yield nanometer-sized or amorphous CaCO3. The synthesis method presented here, which involves slow mixing of concentrated solutions of CaCl2 ¬and (NH4)2CO3, produces single crystals of rhombohedral calcite in 2 to 4 days. Variations on the experimental method, including changes in pH and solution concentration, were explored to optimize the synthesis. Scanning Electron Microscope images show the differences in size and purity observed when the crystals are grown at pH values ranging from 2 to 6. The crystals grown from solutions of pH 2 were large (up to 500 micrometers in diameter) with minimal polycrystalline calcium carbonate, while crystals grown from solutions with pH values beyond 4 were smaller (up to 100 micrometers in diameter) with significant polycrystalline calcium carbonate. The synthesis method, materials characterization, and use in future actinide contaminant studies will be discussed.

  13. The structure and diffusion behaviour of the neurotransmitter γ-aminobutyric acid (GABA) in neutral aqueous solutions

    International Nuclear Information System (INIS)

    Rodrigo, M.M.; Esteso, M.A.; Barros, M.F.; Verissimo, L.M.P.; Romero, C.M.; Suarez, A.F.; Ramos, M.L.; Valente, A.J.M.; Burrows, H.D.; Ribeiro, A.C.F.

    2017-01-01

    Highlights: • Diffusion coefficients and densities of binary aqueous solutions of γ-aminobutyric acid (GABA). • Dependence on both shape and size of GABA on its diffusion. • Interactions intramolecular and the solute-water interactions in these systems. - Abstract: GABA (γ-aminobutyric acid) is a non-protein amino acid with important physiological properties, and with considerable relevance to the food and pharmaceutical industries. Particular interest has focused on its role as an inhibitory neurotransmitter in the mammalian cerebral cortex. In this paper, we report density and mutual diffusion coefficients of GABA in non-buffered aqueous solutions (0.001–0.100) mol·dm −3 at 298.15 K. Under these conditions, 1 H and 13 C NMR spectroscopy and pH measurements show that it is present predominantly as a monomeric zwitterionic species. Diffusion coefficients have been computed assuming that this behaves as the binary system GABA/water. From density and intermolecular diffusion coefficients measurements, the molar volume, hydrodynamic radii, R h , diffusion coefficients at infinitesimal concentration, D 0 , activity coefficients and the thermodynamic factors, F T , have been estimated. Within experimental error, the hydrodynamic volume calculated from this is identical to the molar volume obtained from density measurements. From the NMR spectra and literature data, it is suggested that this amino acid diffuses in aqueous solution as a curved, coil-like hydrated zwitterionic entity.

  14. Solvation behaviour of biologically active compounds in aqueous solutions of antibacterial drug amoxicillin at different temperatures

    International Nuclear Information System (INIS)

    Singla, Meenu; Kumar, Harsh; Jindal, Rajeev

    2014-01-01

    Highlights: • Densities and speeds of sound of amino acids in aqueous amoxicillin solutions. • Partial molar volumes and compressibility of transfer. • Group contribution have been calculated. • (Ion + hydrophilic) and (hydrophilic + hydrophilic) interactions are present. • Pair-wise interactions are dominant in the mixtures. - Abstract: The interactions of glycine (Gly), L-alanine (Ala), L-valine (Val) and L-Leucine (Leu) with drug amoxicillin (AMX) as a function of temperature have been investigated by combination of volumetric and acoustic measurements. Densities and speeds of sound of amino acids in aqueous solutions of amoxicillin have been measured at T = (305.15, 310.15 and 315.15) K and atmospheric pressure. The apparent molar volume (V ϕ ), the partial molar volume (V ϕ 0 ) and standard partial molar volumes of transfer (ΔV ϕ 0 ) for amino acids from water to aqueous amoxicillin solutions have been calculated from density data. Group contributions of amino acids to partial molar volume were determined. Partial molar isentropic compression (κ ϕ,s ) and partial molar isentropic compression of transfer (Δκ ϕ,S 0 ) have been calculated from speed of sound data. The pair and triplet interaction coefficient have been calculated from both the properties. The results have been explained based on competing patterns of interactions of co-solvents and the solute

  15. Erbium(III) in aqueous solution: an ab initio molecular dynamics study.

    Science.gov (United States)

    Canaval, Lorenz R; Sakwarathorn, Theerathad; Rode, Bernd M; Messner, Christoph B; Lutz, Oliver M D; Bonn, Günther K

    2013-12-05

    Structural and dynamical properties of the erbium(III) ion in water have been obtained by means of ab initio quantum mechanical charge field molecular dynamics (QMCF-MD) simulations for the ground state and an excited state. The quality of the simulations has been monitored by recording UV/vis and Raman spectra of dilute solutions of ErCl3 and Er(NO3)3 in water and by comparison with EXAFS data from literature. Slight deviations between these data can be mainly attributed to relativistic effects, which are not sufficiently considered by the methodological framework. In both simulations, a mixture of coordination numbers eight and nine and a ligand exchange on the picosecond range are observed. The strength of the Er-ligand bond is considerably lower than that of trivalent transition metal ions but higher than that for La(III) and Ce(III) in aqueous solution. The main difference between ground state and excited state is the ligand exchange rate of the first shell. The second hydration shell is stable in both cases but with significantly different properties.

  16. Molecular dispersion energy parameters for alkali and halide ions in aqueous solution

    International Nuclear Information System (INIS)

    Reiser, S.; Deublein, S.; Hasse, H.; Vrabec, J.

    2014-01-01

    Thermodynamic properties of aqueous solutions containing alkali and halide ions are determined by molecular simulation. The following ions are studied: Li + , Na + , K + , Rb + , Cs + , F − , Cl − , Br − , and I − . The employed ion force fields consist of one Lennard-Jones (LJ) site and one concentric point charge with a magnitude of ±1 e. The SPC/E model is used for water. The LJ size parameter of the ion models is taken from Deublein et al. [J. Chem. Phys. 136, 084501 (2012)], while the LJ energy parameter is determined in the present study based on experimental self-diffusion coefficient data of the alkali cations and the halide anions in aqueous solutions as well as the position of the first maximum of the radial distribution function of water around the ions. On the basis of these force field parameters, the electric conductivity, the hydration dynamics of water molecules around the ions, and the enthalpy of hydration is predicted. Considering a wide range of salinity, this study is conducted at temperatures of 293.15 and 298.15 K and a pressure of 1 bar

  17. Removal of 4-Chlorophenol from Aqueous Solutions Using Graphene Oxide Nanoporous Adsorbent

    Directory of Open Access Journals (Sweden)

    akbar eslami

    2015-03-01

    Full Text Available In this study, graphene oxide was used as a nanostructured adsorbent with properties supposedly better than other common adsorbents to remove 4-chlorophenol from aqueous solutions. For this purpose, graphene oxide was initially synthesized using the Hummer's method and x-ray diffraction and scanning electron microscopy were employed to identify its morphology and structure. The variables involved in the absorption process (including 4-chlorophenol initial concentration, adsorbent dosage, and pH were investigated based on the one-factor-at-a-time method. Eventually, the data were confirmed against the Langmuir and Freundlich isotherms. It was found that the adsorption process reached equilibrium in 20 minutes. A dosage of 0.4 g/L graphene oxide at pH=8 brought about 90% removal of 10 mg/L 4-chlorophenol within 5 minutes. The adsorption isotherm was described well by the Langmuir isotherm model and the values for R2 and RL were recorded as 0.99 for and 0.34, respectively. Being a low cost and highly efficient process, the adsorption process using graphene oxide adsorbent may be recommended for the reduction and elimination of pollutants in the environment, especially those in aqueous solutions.

  18. High density liquid structure enhancement in glass forming aqueous solution of LiCl

    Science.gov (United States)

    Camisasca, G.; De Marzio, M.; Rovere, M.; Gallo, P.

    2018-06-01

    We investigate using molecular dynamics simulations the dynamical and structural properties of LiCl:6H2O aqueous solution upon supercooling. This ionic solution is a glass forming liquid of relevant interest in connection with the study of the anomalies of supercooled water. The LiCl:6H2O solution is easily supercooled and the liquid state can be maintained over a large decreasing temperature range. We performed simulations from ambient to 200 K in order to investigate how the presence of the salt modifies the behavior of supercooled water. The study of the relaxation time of the self-density correlation function shows that the system follows the prediction of the mode coupling theory and behaves like a fragile liquid in all the range explored. The analysis of the changes in the water structure induced by the salt shows that while the salt preserves the water hydrogen bonds in the system, it strongly affects the tetrahedral hydrogen bond network. Following the interpretation of the anomalies of water in terms of a two-state model, the modifications of the oxygen radial distribution function and the angular distribution function of the hydrogen bonds in water indicate that LiCl has the role of enhancing the high density liquid component of water with respect to the low density component. This is in agreement with recent experiments on aqueous ionic solutions.

  19. Measuring the density and viscosity of H2S-loaded aqueous methyldiethanolamine solution

    International Nuclear Information System (INIS)

    Shokouhi, Mohammad; Ahmadi, Reza

    2016-01-01

    Highlights: • Measurement solubility of H 2 S in 46.78 mass% MDEA aqueous solutions. • Measurement density of H 2 S loaded of MDEA aqueous solution. • Measurement viscosity of H 2 S loaded of MDEA aqueous solution. • Correlation of the density and viscosity of H 2 S loaded of MDEA aqueous solution using modified setchenow equation. - Abstract: The density and viscosity of H 2 S-loaded aqueous 46.78 mass% methyldiethanolamine solution were experimentally measured accompanied with the solubility of H 2 S at temperatures (313.15, 328.15 and 343.15) K, pressures from vapor pressure of fresh solution up to 1.0 MPa and loadings up to 1.00 mol of H 2 S per 1 mol of amine. All experimental trials have been carried out using the new setup developed in our laboratory. It was observed that both density and viscosity of mixtures decrease by increasing temperature and density increase by increasing acid gas solubility (loading) by about 4.7%, whereas viscosity has a complicated behavior with H 2 S solubility. Viscosity decreases by increasing acid gas solubility (loading) at 313.15 K by about 20.6% and at 328.15 K by about 15.0%, but it is comparable at 343.15 K in terms of H 2 S solubility. Finally, the experimental density and viscosity data correlated using Modified Setchenow equation.

  20. Effect of gamma irradiation on viscosity of aqueous solutions of some natural polymers

    International Nuclear Information System (INIS)

    Nguyen Tan Man; Truong Thi Hanh; Le Quang Luan; Le Hai; Nguyen Quoc Hien

    2000-01-01

    Effect of gamma irradiation on viscosity of aqueous solution of alginate and carbon xylmethyl cellulose (CMC) irradiated in solid state has been carried out. the viscosity of aqueous solution of alginate and CMC decreased remarkably with increasing dose and the viscosity of 2% solution of above polymers irradiated at 50 kGy was about 100 times lower than the original one. (author)

  1. XPS study of the passive layers formed on lead in aqueous nitrate solutions

    International Nuclear Information System (INIS)

    Uchida, Miho; Okuwaki, Akitsugu

    1997-01-01

    The analysis of the lead surface immersed in aqueous nitrate solutions by X-ray photoelectron spectroscopy (XPS) shows the formation of passive oxide layer containing nitrogen compound. The oxide layer formed on the lead surface in aqueous ammonium nitrate solution was hydrolyzed and cracked. (author)

  2. Effect of pH on the corrosion behaviour of SUS321 in the ammonia aqueous solution

    International Nuclear Information System (INIS)

    Park, Sang Yoon; Jeong, Y. H.; Baek, J. H.; Choi, B. K.; Lee, M. H.; Choi, B. S.; Yoon, J. H.; Lee, D. J.

    2003-02-01

    The corrosion characteristics of SUS321 for pressure vessel of SMART in pure water, ammonia aqueous solutions of pH 8.5 ∼ 11.5 at 300 .deg. C were evaluated by using static autoclaves. SUS321 specimen in the high temperature ammonia aqueous solution has weight gain or loss by the 4 reactions. And it depends on the refreshing period of the aqueous solution. So additional experiments by recirculating loop system were required to evaluate the corrosion behaviour of SUS321 in the ammonia aqueous solution

  3. Inorganic nanoparticles for transfection of mammalian cells and removal of viruses from aqueous solutions.

    Science.gov (United States)

    Link, Nils; Brunner, Tobias J; Dreesen, Imke A J; Stark, Wendelin J; Fussenegger, Martin

    2007-12-01

    Owing to their small size, synthetic nanoparticles show unprecedented biophysical and biochemical properties which may foster novel advances in life-science research. Using flame-spray synthesis technology we have produced non-coated aluminum-, calcium-, cerium-, and zirconium-derived inorganic metal oxide nanoparticles which not only exhibit high affinity for nucleic acids, but can sequester such compounds from aqueous solution. This non-covalent DNA-binding capacity was successfully used to transiently transfect a variety of mammalian cells including human, reaching transfection efficiencies which compared favorably with classic calcium phosphate precipitation (CaP) procedures and lipofection. In this straightforward protocol, transfection was enabled by simply mixing nanoparticles with DNA in solution prior to addition to the target cell population. Transiently transfected cells showed higher production levels of the human secreted glycoprotein SEAP compared to isogenic populations transfected with established technologies. Inorganic metal oxide nanoparticles also showed a high binding capacity to human-pathogenic viruses including adenovirus, adeno-associated virus and human immunodeficiency virus type 1 and were able to clear these pathogens from aqueous solutions. The DNA transfection and viral clearance capacities of inorganic metal oxide nanoparticles may provide cost-effective biopharmaceutical manufacturing and water treatment in developing countries.

  4. Pitting corrosion of zirconium in aqueous solution

    International Nuclear Information System (INIS)

    El Shayeb, H.A.; Abd El Wahab, F.M.; Abd Elk Meguid, E.A.

    1994-01-01

    The open circuit potentials of the Zr electrode are followed as a function of time in various aqueous solutions till attainment of steady state values.The results are discussed on the basis of oxide film thickening and repair. Pitting corrosion of Zr was examined in chloride solutions using the potentiodynamic technique. The effect of some inorganic and organic additives was also investigated for inhibiting the pitting corrosion of Zr and the relative performance is presented and discussed. (author). 21 refs., 6 figs., 1 tab

  5. Stabilizers of edaravone aqueous solution and their action mechanisms. 2. Glutathione

    OpenAIRE

    Tanaka, Masahiko; Motomiya, Satsuki; Fujisawa, Akio; Yamamoto, Yorihiro

    2017-01-01

    Edaravone (3-methyl-1-phenyl-2-pyrazolin-5-one) has garnered attention since its approval for amyotrophic lateral sclerosis in Japan (2015) and the United States (2017). Edaravone is administered intravenously, and as such, is distributed in the form of an aqueous solution. However, aqueous solutions of edaravone are very unstable because they present as edaravone anions, which become edaravone radicals when the anion donates an electron to free radicals including oxygen. In this study, gluta...

  6. Kinetics of the decomposition and the estimation of the stability of 10% aqueous and non-aqueous hydrogen peroxide solutions

    Directory of Open Access Journals (Sweden)

    Zun Maria

    2014-12-01

    Full Text Available In this study, the stability of 10% hydrogen peroxide aqueous and non-aqueous solutions with the addition of 6% (w/w of urea was evaluated. The solutions were stored at 20°C, 30°C and 40°C, and the decomposition of hydrogen peroxide proceeded according to first-order kinetics. With the addition of the urea in the solutions, the decomposition rate constant increased and the activation energy decreased. The temperature of storage also affected the decomposition of substance, however, 10% hydrogen peroxide solutions prepared in PEG-300, and stabilized with the addition of 6% (w/w of urea had the best constancy.

  7. Fluoresence quenching of riboflavin in aqueous solution by methionin and cystein

    International Nuclear Information System (INIS)

    Droessler, P.; Holzer, W.; Penzkofer, A.; Hegemann, P.

    2003-01-01

    The fluorescence quantum distributions, fluorescence quantum yields, and fluorescence lifetimes of riboflavin in methanol, DMSO, water, and aqueous solutions of the sulphur atom containing amino acids methionin and cystein have been determined. In methanol, DMSO, and water (pH=4-8) only dynamic fluorescence reduction due to intersystem crossing and internal conversion is observed. In aqueous methionin solutions of pH=5.25-9 a pH independent static and dynamic fluorescence quenching occurs probably due to riboflavin anion-methionin cation pair formation. In aqueous cystein solutions (pH range from 4.15 to 9) the fluorescence quenching increases with rising pH due to cystein thiolate formation. The cystein thiol form present at low pH does not react with neutral riboflavin. Cystein thiolate present at high pH seems to react with neutral riboflavin causing riboflavin deprotonation (anion formation) by cystein thiolate reduction to the cystein thiol form

  8. Effect of the hydrophilic block length on the surface-active and micellar thermodynamic properties of oxyethylene-oxybutylene diblock copolymers in aqueous solution

    International Nuclear Information System (INIS)

    Khan, A.; Usman, M.; Siddiq, M.; Fatima, G.; Harrison, W.

    2009-01-01

    The effect of hydrophilic block length on the surface and micellar thermodynamic properties of aqueous solution of E/sub 40/B/sub 8/, E/sub 80/B/sub 8/ and E/sub 120/B/sub 8/ diblock copolymers, were studied by surface tension measurements over a wide concentration and temperature range; where E stands for an oxyethylene unit and B for an oxybutylene unit. Like conventional surfactants, two breaks (change in the slope) were observed in the surface tension vs logarithm of concentration curve for all the three copolymers. Surface tension measurements were used to estimate surface excess concentrations (r m), area per molecule at air/water interface a and thermodynamic parameters for all adsorption of the pre-micellar region in the temperature range 20 to 50 degree C. Likewise the critical micelle concentration, CMC and thermodynamic parameters for micellization were also calculated for the post-micellar solutions at all temperatures. For comparison the thermodynamic parameters of adsorption and micellization are discussed in detail. The impact of varying E-block length and temperature on all calculated parameters are also discussed. This study shows the importance of hydrophobic-hydrophilic-balance (HHB) of copolymers on various surface and micellar properties. (author)

  9. Eosin Removal Properties of Organo-Local Clay from Aqueous Solution

    OpenAIRE

    Rawan Al-Faze; Fethi Kooli

    2014-01-01

    Local clay from Al-Madinah Al-Munawwarah was modified by a solution of cetyltrimethylammonium bromide (C16TMABr) at different initial concentrations. The organoclays were characterized by PXRD, TGA, FTIR and N2 adsorption isotherms. The ability of these samples to remove the dye eosin is evaluated. The removal properties of organoclays were dependent on the content of C16TMA cations, the initial concentrations of eosin, temperature of the removal process, the mass of the used organoclays. T...

  10. Photocatalytic degradation properties of α-Fe2O3 nanoparticles for dibutyl phthalate in aqueous solution system

    Science.gov (United States)

    Liu, Yue; Sun, Nan; Hu, Jianshe; Li, Song; Qin, Gaowu

    2018-04-01

    The phthalate ester compounds in industrial wastewater, as kinds of environmental toxic organic pollutants, may interfere with the body's endocrine system, resulting in great harm to humans. In this work, the photocatalytic degradation properties of dibutyl phthalate (DBP) were investigated using α-Fe2O3 nanoparticles and H2O2 in aqueous solution system. The optimal parameters and mechanism of degradation were discussed by changing the morphology and usage amount of catalysts, the dosage of H2O2, pH value and the initial concentration of DBP. Hollow α-Fe2O3 nanoparticles showed the highest degradation efficiency when 30 mg of catalyst and 50 µl of H2O2 were used in the DBP solution with the initial concentration of 13 mg l-1 at pH = 6.5. When the reaction time was 90 min, DBP was degraded 93% for the above optimal parameters. The photocatalytic degradation mechanism of DBP was studied by the gas chromatography-mass spectrometry technique. The result showed that the main degradation intermediates of DBP were ortho-phthalate monobutyl ester, methyl benzoic acid, benzoic acid, benzaldehyde, and heptyl aldehyde when the reaction time was 2 h. DBP and its intermediates were almost completely degraded to CO2 and H2O in 12 h in the α-Fe2O3/ H2O2/UV system.

  11. Removal of Nickel from Aqueous Solution by Hard-Shell Pistachios

    Directory of Open Access Journals (Sweden)

    Shayan Shamohammadi

    2013-08-01

    Full Text Available Nickel is one of the heavy metals which commonly can be found in industrial wastewater. Many studies have been done on agricultural waste for the removal of nickel from aqueous solutions. The purpose of this study is to identify hard-shell pistachios as a local attraction for removal of nickel from aqueous solution. Nickel adsorption isotherm models are studied using shell pistachios. Pistachio shell was chosen which its particle size is between 800-600 microns. The stock solution of nickel ions was prepared mixing nickel nitrate with distilled water. The results showed that the maximum absorption efficiency occurs (73.3% at pH=8. Also, it was shown that with increasing adsorbent dose, equilibrium time decreased within constant concentration. Examination of uptake isotherm models showed that models of Freundlich, BET, Radke-Praunitz, Redlich-Peterson and Sips describe data in 97% level of confidence well,  however Freundlich and Sips isotherm models has the lowest error factor 0.10597 and 0/10598 respectively and the highest correlation coefficient (0.9785. Comparison of adsorbent capacity within removal of nickel from aqueous solution shows that Pistachio shell with special absorbent surface of 1.7 m2/g and uptake capacity of 0.3984 mg/g is proper than adsorbents of Kaolinite, Bagasse, sludge-ash.

  12. Molecular mechanism of the viscosity of aqueous glucose solutions

    Science.gov (United States)

    Bulavin, L. A.; Zabashta, Yu. F.; Khlopov, A. M.; Khorol'skii, A. V.

    2017-01-01

    Experimental relations are obtained for the viscosity of aqueous glucose solutions in the temperature range of 10-80°C and concentration range 0.01-2.5%. It is found that the concentration dependence of fluidity is linear when the concentration is higher than a certain value and varies at different temperatures. The existence of such a dependence indicates that the mobilities of solvent and solute molecules are independent of the concentration of solutions. This assumption is used to construct a theoretical model, in which the structure of an aqueous glucose solution is presented as a combination of two weakly interacting networks formed by hydrogen bonds between water molecules and between glucose molecules. Theoretical relations are obtained using this model of network solution structure for the concentration and temperature dependence of solution viscosity. Experimental data are used to calculate the activation energies for water ( U w = 3.0 × 10-20 J) and glucose molecules ( U g = 2.8 × 10-20 J). It is shown that the viscosity of a solution in such a network structure is governed by the Brownian motion of solitons along the chains of hydrogen bonds. The weak interaction between networks results in the contributions to solution fluidity made by the motion of solitons in both of them being almost independent.

  13. Ion from Aqueous Solution using Magnetite, Activated Carbon

    African Journals Online (AJOL)

    ADOWIE PERE

    Thermodynamic studies on Adsorption of lead (II) Ion from Aqueous Solution using. Magnetite ... process industries and agricultural activities, which tends to ... osmosis. These processes are however, not economically feasible for small scale industries .... Freundlich coefficient. ..... from binary component system, Beni-suef.

  14. Simultaneous determination of nitric acid and uranium concentrations in aqueous solution from measurements of electrical conductivity, density, and temperature

    International Nuclear Information System (INIS)

    Spencer, B.B.

    1991-01-01

    Nuclear fuel reprocessing plants handle aqueous solutions of nitric acid and uranium in large quantities. Automatic control of process operations requires reliable measurements of these solutes concentration, but this is difficult to directly measure. Physical properties such as solution density and electrical conductivity vary with solute concentration and temperature. Conductivity, density and temperature can be measured accurately with relatively simple and inexpensive devices. These properties can be used to determine solute concentrations will good correlations. This paper provides the appropriate correlations for solutions containing 2 to 6 Molar (M) nitric acid and 0 to 300 g/L uranium metal at temperatures from 25--90 degrees C. The equations are most accurate below 5 M nitric acid, due to a broad maximum in the conductivity curve at 6 M. 12 refs., 9 figs., 6 tabs

  15. Photoionization of rhodamine dyes adsorbed at the aqueous solution surfaces investigated by synchrotron radiation

    International Nuclear Information System (INIS)

    Seno, Koichiro; Ishioka, Toshio; Harata, Akira; Hatano, Yoshihiko

    2002-01-01

    Photoionization spectroscopy using synchrotron radiation as a photon source was applied to the aqueous solution surfaces of rhodamine B (RhB), rhodamine 6G (Rh6G), and rhodamine 101 (Rh101) with their concentration of 0-100 μmol dm -3 . Synchrotron radiation was irradiated upon the solution surface between two electrodes in the photon energy range of 4-7 eV, and photoionization current was measured by a pico-ammeter. The photocurrent for each of the rhodamine aqueous solution surface showed an increase with the photon energy above a threshold photon energy. The photoionization threshold of RhB at the aqueous solution surface was 5.6 eV, which was smaller than that in the gas phase. The intensity of photoionization current of Rh6G was smaller than that of RhB or Rh101. Photoionization processes and the state of Rhodamine dye molecules at the aqueous solution surface were discussed in connection with results of surface tension measurements. (author)

  16. Removal of radium from aqueous sulphate solutions

    International Nuclear Information System (INIS)

    Weir, D.R.; Masters, J.T.; Neven, M.

    1983-01-01

    Radium is often present in ores and an aqueous solution associated with the ore may consequently contain dissolved radium. It is frequently necessary to remove radium from such solutions to reduce the total radium content to a prescribed low level before the solution can be returned to the environment. The present invention is based on the discovery that the total radium content can be reduced to a satisfactory level within a reasonable time by adding a soluble barium salt to a radium-containing sulphate solution which also contains dissolved magnesium at a pH not greater than about 0 to precipitate radium as barium radium sulphate, raising the pH to at least 11 to precipitate an insoluble magnesium compound which collects the barium radium sulphate precipitate, and separating substantially all of the precipitates from the solution

  17. Hydrate phase equilibria of CO2+N2+aqueous solution of THF, TBAB or TBAF system

    DEFF Research Database (Denmark)

    Sfaxi, Imen Ben Attouche; Durand, Isabelle; Lugo, Rafael

    2014-01-01

    We report hydrate dissociation conditions of CO2 (15 and 30mol%)+N2 (85 and 70mol%) in the presence of aqueous solutions of THF, TBAB or TBAF. The concentrations of TBAB and TBAF in the aqueous solutions are 5wt% and 9wt% while THF concentration in aqueous solution is 3mol%. Two different experim...

  18. Recrystallization of freezable bound water in aqueous solutions of medium concentrations

    Institute of Scientific and Technical Information of China (English)

    赵立山; 潘礼庆; 纪爱玲; 曹则贤; 王强

    2016-01-01

    For aqueous solutions with freezable bound water, vitrification and recrystallization are mingled, which brings diffi-culty to application and misleads the interpretation of relevant experiments. Here, we report a quantification scheme for the freezable bound water based on the water-content dependence of glass transition temperature, by which also the concentra-tion range for the solutions that may undergo recrystallization finds a clear definition. Furthermore, we find that depending on the amount of the freezable bound water, different temperature protocols should be devised to achieve a complete recrys-tallization. Our results may be helpful for understanding the dynamics of supercooled aqueous solutions and for improving their manipulation in various industries.

  19. Orientational order and dynamics of water in bulk and in aqueous solutions of uranyl ions

    International Nuclear Information System (INIS)

    Chopra, Manish; Choudhury, Niharendu

    2014-01-01

    Molecular dynamics simulations in canonical ensemble of aqueous solutions of uranyl nitrate and bulk water at ambient condition have been carried out to investigate orientational order and dynamics of water. The orientational distributions of water around a central water molecule in bulk water and around a uranyl ion in an aqueous uranyl solution have been calculated. Orientational dynamics of water in bulk and in aqueous uranyl nitrate solution have also been analysed. (author)

  20. Removal of Murexide from Aqueous Solution Using Pomegranate bark as adsorbent

    International Nuclear Information System (INIS)

    Ishaq, M.I.; Shakirullah, M.; Ahmad, I.; Sultan, S.; Saeed, K.

    2012-01-01

    The adsorption of Murexide from aqueous solution onto the Pomegranate bark was investigated at room temperature. The morphological study presented that the HNO/sub 3/ treatment increased the surface roughness of the adsorbent. EDX studies show that the untreated Pomegranate bark had carbon content (52 wt %) and oxygen content (44 wt %) while in the case of HNO/sub 3/ treated pomegranate bark, the carbon quantity decreased (42 wt %) and oxygen quantity (52 wt %) increased. The results showed that the adsorption of Murexide dye from aqueous solution was increased as increased the adsorption time and then equilibrium was reached after 30 min of adsorption time. The HNO/sub 3/ treated Pomegranate bark adsorbed high quantity of Murexide (1.7 mg/g) as compared to untreated Pomegranate bark (0.73 mg/g), which might be due to increased surface roughness. The adsorption of Murexide was also studied at different pH, which presented that low pH was favorable for the removal of color material from aqueous solution. (author)

  1. Interactions of dipeptides with Triton X-100 in aqueous solution: A volumetric and spectroscopic study

    International Nuclear Information System (INIS)

    Yan, Zhenning; Wu, Shuangyan; Pan, Qi; Geng, Rui; Gu, Bixin; Wang, Jianji

    2014-01-01

    Highlights: • The values of V 2,ϕ o and Δ t V° are positive. • Interactions of Triton X-100 with charged and polar groups of dipeptides dominate. • Addition of dipeptide in water decreases the c cmc and the aggregation number of Triton X-100. • The affinity between dipeptide and Triton X-100 micelle increases with the increase in the length of alkyl chain of peptides. • Triton X-100 interacts with dipeptides more weakly than SDS. -- Abstract: The interactions of dipeptides with Triton X-100 in aqueous solution have been investigated by means of density, fluorescence spectroscopy and UV–vis spectroscopy. The standard partial molar volume (V 2,ϕ o ), standard partial molar volume of transfer for dipeptide from water to aqueous Triton X-100 solution (Δ t V o ) and partial molar expansibility (E ϕ o ) have been calculated from density data. Fluorescence spectroscopy was used to estimate the critical micellar concentration (c cmc ) and micelle aggregation number of Triton X-100 in aqueous dipeptide solutions. Effects of temperature and hydrocarbon chain length of dipeptides on the volumetric properties of dipeptide and critical micelle concentration (c cmc ) of Triton X-100 were examined. The pyrene fluorescence spectra were also used to study the change of micropolarity produced by the interactions of Triton X-100 with dipeptides. From the results of UV–vis absorption spectra, the binding constant between dipeptide and Triton X-100 above the c cmc was determined. The results have been interpreted in terms of solute–solvent interactions and structural changes in the mixed solutions

  2. Implementation of equilibrium aqueous speciation and solubility (EQ3 type) calculations into Cantera for electrolyte solutions.

    Energy Technology Data Exchange (ETDEWEB)

    Moffat, Harry K.; Jove-Colon, Carlos F.

    2009-06-01

    In this report, we summarize our work on developing a production level capability for modeling brine thermodynamic properties using the open-source code Cantera. This implementation into Cantera allows for the application of chemical thermodynamics to describe the interactions between a solid and an electrolyte solution at chemical equilibrium. The formulations to evaluate the thermodynamic properties of electrolytes are based on Pitzer's model to calculate molality-based activity coefficients using a real equation-of-state (EoS) for water. In addition, the thermodynamic properties of solutes at elevated temperature and pressures are computed using the revised Helgeson-Kirkham-Flowers (HKF) EoS for ionic and neutral aqueous species. The thermodynamic data parameters for the Pitzer formulation and HKF EoS are from the thermodynamic database compilation developed for the Yucca Mountain Project (YMP) used with the computer code EQ3/6. We describe the adopted equations and their implementation within Cantera and also provide several validated examples relevant to the calculations of extensive properties of electrolyte solutions.

  3. Physicochemical Properties of Amino Acids in Aqueous Caffeine Solution at 25, 30, 35 and 40 ℃

    Institute of Scientific and Technical Information of China (English)

    ALI A.; SABIR S.; SHAHJAHAN; HYDER S.

    2006-01-01

    Density, viscosity, and refractive index, for glycine, DL-alanine, L-serine and DL-valine have been determined in aqueous solution of 0.05 mol/kg caffeine as a function of amino acid (AA) concentration at 25, 30, 35, and 40 ℃.The density data have been used to compute apparent molar volume. The partial molar volume (limiting apparent molar volume) was obtained by applying the Masson's equation. The viscosity data have been analyzed by means of Jones-Dole equation. The values of Falkenhagen coefficient and Jones-Dole coefficient thus obtained are used to interpret the solute-solute and solute-solvent interactions, respectively. Hydration number was also computed. The transition-state theory was applied to obtain the activation parameters of viscous flow, I.e., free energy of activation per mole of solvent, and solute. The enthalpy and entropy of activation of viscous flow were computed for the system. Refractive index was used to calculate molar refractivity of the mixtures. The results have been interpreted in the lightof various interactions occurring between the components of the mixtures under applied experimental conditions.

  4. Photolysis of imidacloprid in aqueous solution

    International Nuclear Information System (INIS)

    Moza, P.N.; Hustert, K.; Feicht, E.; Kettrup, A.

    1998-01-01

    The photolysis of the insecticide imidacloprid in aqueous solution has been examined. Irradiation at 290 nm resulted in 90 % substrate transformation in 4 h. The degradation approximately followed first order kinetics; the rate constant is 1.6 × 10 −4 s −1 and half-life 1.2 h. 6-Chloronicotinaldehyde, N-methylnicotinacidamide, 1-(6-chloronicotinyl)imidazolidone and 6-chloro-3-pyridyl-methylethylendiamine were the main photoproducts identified by CG-MS analysis. (author)

  5. Radiation-induced nitration of organic compounds in aqueous solutions

    International Nuclear Information System (INIS)

    Ershov, B.G.; Gordeev, A.V.; Bykov, G.L.

    2009-01-01

    Radiation-induced nitration of organic compounds in aqueous solutions was studied. It was found that γ-irradiation of solutions containing acetic and nitric acid and/or their salts gives nitromethane. Dependences of the product yield on the absorbed dose and the contents of components were established. The mechanism of radiation nitration involving radicals is discussed. (author)

  6. On mechanism of chlorophos radiation-chemical decomposition in aqueous solutions

    International Nuclear Information System (INIS)

    Danilin, D.I.; Shubin, V.N.

    1992-01-01

    Quantitative indices of chlorophos decomposition in a aqueous solution and in solutions with a number of additions are studied. Chlorine ions and substances containing the carbonyl group are found among the products of gamma-irradiation of low-concentration chlorophos solutions. The data supporting the running of radiation destructive reactions of reduction nature rather than oxidation type, are presented

  7. The synthesis of nucleotide in the aqueous solution induced by low energy ions

    International Nuclear Information System (INIS)

    Shi Huaibin; Shao Chunlin; Wang Xiangqin; Yu Zengliang

    2000-08-01

    A new apparatus was designed to induce reactions in aqueous solution by introducing low energy ions into the aqueous solution, this apparatus overcome the defaults of the old ones which demanded vacuum and made it possible to study the action among solutions, it also expanded the ion implantation biology. The role of low energy ions was introduced into the study of the origin of life, primitive earth conditions were imitated to study prior-life synthesis of nucleotide by introducing low energy ions into aqueous solution, low energy N + was implanted into adenine supersaturation solution including D-ribose and NH 4 H 2 PO 4 , it was confirmed that 5'-AMP was gained by HPLC analysis of the products. In comparison with other methods in this field, this one is simpler and nearer to the primitive earth conditions, thus it provided a new try for the studying of the origin of life

  8. A New Efficient Analytical Method for Picolinate Ion Measurements in Complex Aqueous Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Parazols, M.; Dodi, A. [CEA Cadarache, Lab Anal Radiochim and Chim, DEN, F-13108 St Paul Les Durance (France)

    2010-07-01

    This study focuses on the development of a new simple but sensitive, fast and quantitative liquid chromatography method for picolinate ion measurement in high ionic strength aqueous solutions. It involves cation separation over a chromatographic CS16 column using methane sulfonic acid as a mobile phase and detection by UV absorbance (254 nm). The CS16 column is a high-capacity stationary phase exhibiting both cation exchange and RP properties. It allows interaction with picolinate ions which are in their zwitterionic form at the pH of the mobile phase (1.3-1.7). Analysis is performed in 30 min with a detection limit of about 0.05 {mu}M and a quantification limit of about 0.15 {mu}M. Moreover, this analytical technique has been tested efficiently on complex aqueous samples from an effluent treatment facility. (authors)

  9. Density, speed of sound, viscosity and refractive index properties of aqueous solutions of vitamins B1.HCl and B6.HCl at temperatures (278.15, 288.15, and 298.15) K

    International Nuclear Information System (INIS)

    Dhondge, Sudhakar S.; Deshmukh, Dinesh W.; Paliwal, Lalitmohan J.

    2013-01-01

    Highlights: ► Study of aqueous solutions of vitamins B 1 .HCl and B 6 .HCl at different temperatures has been presented. ► These are important vitamins. ► Different interactions among solute and solvents have been investigated. ► The results are interpreted in terms of water structure making and breaking effects due to cations. -- Abstract: The experimental values of density (ρ), speed of sound (u), absolute viscosity (η) and refractive index (n D ) properties are reported for aqueous solutions of thiamine hydrochloride (vitamin B 1 .HCl) and pyridoxine hydrochloride (vitamin B 6 .HCl) within the concentration range (0.01 to 0.55) mol ⋅ kg −1 at three different temperatures, viz. T/K = 278.15, 288.15, and 298.15. Using experimental data, different derived parameters such as the apparent molar volume of solute (ϕ V ), isentropic compressibility of solution (β S ), apparent molar isentropic compressibility of solute (ϕ KS ) and relative viscosity of solution (η r ) have been computed. The limiting values of apparent molar volume (ϕ V 0 ) and apparent molar isentropic compressibility (ϕ KS 0 ) have been obtained. The limiting apparent molar expansivity (ϕ E 0 ) of solute, coefficient of thermal expansion (α ∗ ) and hydration numbers (n h ) of above vitamins in the aqueous medium have also been estimated. The experimental values of relative viscosity are used to calculate the Jones–Dole equation viscosity A and B coefficients for the hydrochlorides. The temperature coefficients of B i.e. (dB/dT) for these solutes have been used to study water structure making and breaking effects due to cations. Further, a discussion is made on the basis of solute–solute and solute–solvent interactions

  10. Volumetric properties of MES, MOPS, MOPSO, and MOBS in water and in aqueous electrolyte solutions

    International Nuclear Information System (INIS)

    Taha, Mohamed; Lee, Ming-Jer

    2010-01-01

    4-Morpholineethanesulfonic acid (MES), 4-morpholinepropanesulfonic acid (MOPS), 3-morpholino-2-hydroxypropanesulfonic acid (MOPSO), and 4-(N-morpholino)butanesulfonic acid (MOBS), are useful for pH control as standard buffers in the physiological region of 5.5-6.7 for MES, 6.5-7.9 for MOPS, 6.2-7.6 for MOPSO, and 6.9-8.3 for MOBS, respectively. On the basis of density measurements at 298.15 K, the apparent molar volumes, V φ , of the above-mentioned buffers in water and in (0.05, 0.16, and 0.25) mol kg -1 aqueous solutions of NaCl, KCl, KBr, and CH 3 COOK have been calculated. The partial molar volumes at infinite dilution, V φ o , obtained from V φ , have been used to calculate the volume of transfer, Δ tr V φ o , from water to aqueous electrolyte solutions. It was found that both V φ o and Δ tr V φ o vary linearly with increasing the number of carbon atoms in the alkyl group side chain of the zwitterionic buffers. These linear correlations have been utilized to estimate the contributions of the zwitterionic end group (morpholinium ion, -SO 3 - ) and -CH 2 - group to V φ o and Δ tr V φ o . The values of V φ o and Δ tr V φ o for some functional group contributions of the zwittierionic buffers with salts have also been reported.

  11. KINETICS OF THE HYDROXYPROPYLATION OF POTATO STARCH IN AQUEOUS-SOLUTION

    NARCIS (Netherlands)

    LAMMERS, G; STAMHUIS, EJ; BEENACKERS, AACM

    Kinetic results are presented for the hydroxypropylation of Potato starch with methyloxirane in aqueous solution. Reaction temperatures were varied from 303 to 362 K. Sodium hydroxide was used as a catalyst. The overall conversion rate of methyloxirane in alkaline starch solution is determined by

  12. Morphology control of brushite prepared by aqueous solution synthesis

    Directory of Open Access Journals (Sweden)

    T. Toshima

    2014-03-01

    Full Text Available Dicalcium phosphate dihydrate (DCPD, CaHPO4·2H2O, also known as brushite, is one of the important bioceramics due to not only diseases factors such as kidney stone and plaque formation but also purpose as fluoride insolubilization material. It is used medicinally to supply calcium, and is of interest for its unique properties in biological and pathological mineralization. It is important to control the crystal morphology of brushite since its chemical reactivity depends strongly on its surface properties; thus, its morphology is a key issue for its applications as a functional material or precursor for other bioceramics. Here, we report the effects of the initial pH and the Ca and phosphate ion concentrations on the morphology of DCPD particles during aqueous solution synthesis. Crystal morphologies were analyzed by scanning electron microscopy and X-ray diffraction. The morphology phase diagram of DCPD crystallization revealed that increasing the initial pH and/or ion concentration transformed DCPD morphology from petal-like into plate-like structures.

  13. Removal of radium from aqueous solutions using adsorbent produced from coconut coir pith

    International Nuclear Information System (INIS)

    Zalina Laili; Muhamat Omar; Mohd Zaidi Ibrahim; Esther Phillip; Mohd Abdul Wahab Yusof; Hassan, A.

    2008-08-01

    A study was conducted to evaluate the potential use of the coconut coir pith as an adsorbent for the removal of radium from aqueous solutions. Experiments to establish adsorptions as a function of pH and contact time were carried out. The results showed that radium adsorption are dependent upon pH and contact time of coconut coir pith with aqueous solutions. 70-80% of radium were adsorbed in the neutral to alkaline pH range. The amount of radium adsorbed also increased with contact time, reaching an optimum after 250 min. Thus, it can be concluded that the coconut coir pith has the potential to be used as an adsorbent in radium removal from aqueous solutions. (Author)

  14. Densities concentrations of aqueous of uranyl nitrate solutions

    International Nuclear Information System (INIS)

    Rodrigo Otero, A.; Rodriguez Hernandez, B.; Fernandez Rodriguez, L.

    1966-01-01

    The ratio density-concentration of aqueous uranyl nitrate solutions expressed as U 3 O 8 grams/liter, U grams/liter and hexahydrate uranyl nitrate weight percent at different temperatures, are established. Experimental values are graphically correlated and compared whit some published data. (Author) 2 refs

  15. Volumetric and viscometric studies of some drugs in aqueous solutions at different temperatures

    International Nuclear Information System (INIS)

    Dhondge, Sudhakar S.; Zodape, Sangesh P.; Parwate, Dilip V.

    2012-01-01

    Highlights: ► Study of aqueous solutions of biologically important compounds has been reported. ► MH is used for treating type II diabetes, RH is in treatment of peptic ulcer and TH is used to treat severe pain. ► All the compounds act as structure makers by volumetric studies. ► MH and RH act as weak structure breakers and TH acts as a weak structure maker by viscometric studies. - Abstract: Density and viscosity measurements are reported for aqueous solutions of the drugs like Metformin hydrochloride (MH), Ranitidine hydrochloride (RH) and Tramadol hydrochloride (TH) at different temperatures T = (288.15, 298.15, and 308.15) K within the concentration range (0 to 0.15) mol · kg −1 . The density and viscosity data are used to obtain apparent molar volume of solute (φ V ) and relative viscosity (η r ) of aqueous solutions at different temperatures. The limiting apparent molar volume of solute (φ V 0 ), limiting apparent molar expansivity (φ E 0 ), thermal expansion coefficient (α ∗ ), hydration number (n h ), Jones–Dole equation viscosity A and B coefficients, experimental slope (S V ) at different temperatures, and temperature coefficient of Bi.e.(dB/dT) at T = 298.15 K were also obtained. The results obtained have been interpreted in terms of solute–solvent and solute–solute interactions and structure making/breaking ability of solute in the aqueous solution.

  16. Comparative study of the physicochemical properties of aqueous solutions of the hydrocarbon and fluorocarbon surfactants and their ternary mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Szymczyk, Katarzyna, E-mail: katarzyna.szymczyk@poczta.umcs.lublin.pl

    2014-03-03

    Highlights: • Acoustic properties of hydrocarbon and fluorocarbon surfactants were studied. • Auerbach’s relation is not proper for mixtures with fluorocarbon surfactants. • Values of the hydration number decreases at concentrations higher than CMC. • FSO100 and its mixtures are the strongest chaotropes. - Abstract: Speed of sound and density of aqueous solutions of hydrocarbon p-(1,1,3,3-tetramethylbutyl) phenoxypoly(ethyleneglycols) (Triton X-100 (TX100), Triton X-165 (TX165)) and fluorocarbon (Zonyl FSN-100 (FSN100), Zonyl FSO-100 (FSO100)) surfactants as well as their ternary mixtures were measured at 293 K. Taking into account these values and the literature data of the surface tension and viscosity of the studied systems, the values of the isentropic compressibility, apparent specific adiabatic compressibility, hydration number, apparent specific volume and Jones Dole’s A and B-coefficients were determined. For the systems containing FSO100 also the values of dB/dT were determined on the basis of the values of viscosity measured at different temperatures. Next, the calculated thermodynamic properties have been discussed in the term of intermolecular interactions between the components of the mixtures.

  17. Removal of Copper(II) Ions in Aqueous Solutions Using Tannin-Rich Plants as Natural Bio-Adsorbents

    Science.gov (United States)

    Paksamut, J.; Boonsong, P.

    2018-03-01

    In this study, the purpose of our interest is to investigatethe adsorption behavior of copper (II) ions in aqueous solution using some tannin-rich plants as natural bio-adsorbents such as mangosteen peels (Garciniamangostana L.), cassava leaves (Manihotesculenta Crantz) and Thai copper pod leaves (Sennasiamea (Lam.)) as powder form in different dosage of adsorbent plant materials.The adsorption capacities at different pH of solution and contact time were performed.All the experiments in this studywere chosen at room temperature by batch technique. From the experimental results showed that cassava leaves gave better adsorbent properties than mangosteen peels and Thai copper pod leaves. The increasing dosage of all adsorbents and contact time have been found to increase adsorption capacities. In this respect, the adsorption capacities depend crucially on the adsorbents and contact time. The optimum pH of copper (II) ions adsorption was pH4. According to this work, it was observed that bioadsorbent materials from tannin-rich plants could be used to remove copper (II) ions from aqueous solutions.

  18. Adsorption behaviors of trivalent actinides and lanthanides on pyridine resin in lithium chloride aqueous solution

    International Nuclear Information System (INIS)

    Tatsuya Suzuki

    2013-01-01

    The adsorption behaviors of trivalent actinides and lanthanides on pyridine resin in lithium chloride aqueous solution were investigated. The adsorbed amounts of lanthanides and the degree of mutual separation of lanthanides increased with an increase in the concentration of lithium chloride in aqueous solution. The group separation of the trivalent actinides and lanthanides was observed. This separation phenomenon is similar in a hydrochloric acid solution. However, the adsorption behavior of lanthanides in lithium chloride is different from their behavior in a hydrochloric acid solution. This fact shows that the adsorption mechanisms of lanthanides in a lithium chloride aqueous solution and in a hydrochloric acid solution are different; the adsorption mechanisms are attributed to the ion exchange in a hydrochloric acid solution, and to the complex formation with pyridine group in a lithium chloride solution. (author)

  19. Dermal absorption of a dilute aqueous solution of malathion

    Directory of Open Access Journals (Sweden)

    Scharf John

    2008-01-01

    Full Text Available Malathion is an organophosphate pesticide commonly used on field crops, fruit trees, livestock, agriculture, and for mosquito and medfly control. Aerial applications can result in solubilized malathion in swimming pools and other recreational waters that may come into contact with human skin. To evaluate the human skin absorption of malathion for the assessment of risk associated with human exposures to aqueous solutions, human volunteers were selected and exposed to aqueous solutions of malathion. Participants submerged their arms and hands in twenty liters of dilute malathion solution in either a stagnant or stirred state. The "disappearance method" was applied by measuring malathion concentrations in the water before and after human exposure for various periods of time. No measurable skin absorption was detected in 42% of the participants; the remaining 58% of participants measured minimal absorbed doses of malathion. Analyzing these results through the Hazard Index model for recreational swimmer and bather exposure levels typically measured in contaminated swimming pools and surface waters after bait application indicated that these exposures are an order of magnitude less than a minimal dose known to result in a measurable change in acetylcholinesterase activity. It is concluded that exposure to aqueous malathion in recreational waters following aerial bait applications is not appreciably absorbed, does not result in an effective dose, and therefore is not a public health hazard.

  20. The role of water in cholinium carboxylate ionic liquid’s aqueous solutions

    International Nuclear Information System (INIS)

    Patinha, David J.S.; Tomé, Liliana C.; Garcia, Helga; Ferreira, Rui; Pereira, Cristina Silva; Rebelo, Luís Paulo N.; Marrucho, Isabel M.

    2015-01-01

    Highlights: • Densities and viscosities of aqueous solutions of cholinium carboxylate ionic liquids. • 1 H NMR experiments were used to probe nanoscale organization of ionic liquids in water. • Different nanoscale organization in water for the 3 ionic liquids. - Abstract: Binary systems composed of water and cholinium carboxylate ionic liquids, namely cholinium lactate ([Ch][Lac]), cholinium propanoate ([Ch][Prop]) and cholinium malonate ([Ch][Mal]) were studied from the neat ionic liquid to very diluted aqueous solutions. Densities and viscosities were measured and atypical behaviors were observed, such as the increasing density of the binary [Ch][Prop] + H 2 O mixtures with increasing water content. In order to get molecular level insights on the IL + H 2 O solvation schemes, 1 H NMR studies were performed. Large deviations were obtained in the aniońs resonances when compared to those of the cation suggesting that water interacts preferentially with the anion counter-part of the ionic liquid. The increasing density of [Ch][Prop] + H 2 O system with increasing water content can be related to the orientation of the alkyl chains, as a result of their nanoscale organization. This behavior was confirmed through the study of the thermophysical properties of [Ch][Hex] + H 2 O mixtures, where this phenomenon is known to occur

  1. Removal of Phenol in Aqueous Solution Using Kaolin Mineral Clay

    International Nuclear Information System (INIS)

    Sayed, M.S.

    2008-01-01

    Kaolin clay were tested for phenol removal as toxic liquid waste from aqueous waste water. Several experimental conditions such as weight and particle size of clay were investigated to study batch kinetic techniques, also the ph and concentration of the phenol solution were carried out. The stability of the Langmuir adsorption model of the equilibrium data were studied for phenol sorbent clay system. Infrared spectra, thermogravimetric and differential thermal analysis techniques were used to characterize the behavior of kaolin clay and kaolin clay saturated with phenol. The results obtained showed that kaolin clay could be used successfully as an efficient sorbent material to remove phenol from aqueous solution

  2. Solidification of radioactive aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Aikawa, Hideaki; Kato, Kiyoshi; Wadachi, Yoshiki

    1970-09-07

    A process for solidifying a radioactive waste solution is provided, using as a solidifying agent a mixture of calcined gypsum and burnt vermiculite. The quantity ratio of the mixture is preferred to be 1:1 by volume. The quantity of impregnation is 1/2 of the volume of the total quantity of the solidifying agent. In embodiments, 10 liters of plutonium waste solution was mixed with a mixture of 1:1 calcined gypsum and burnt vermiculite contained in a 20-liter cylindrical steel container lined with asphalt. The plutonium waste solution from the laboratory was neutralized with a caustic soda aqueous solution to prevent explosion due to the nitration of organic compounds. The neutralization is not always necessary. A market available dental gypsum was calcined at 400 to 500/sup 0/C and a vermiculite from Illinois was burnt at 1,100/sup 0/C to prepare the agents. The time required for the impregnation with 10 liters of plutonium solution was four minutes. After impregnation, the temperature rose to 40/sup 0/C within 30 minutes to one hour. Next, it was cooled to room temperature by standing for 3-4 hours. Solidification time was about 1 hour. The Japan Atomic Energy Research Insitute had treated and disposed about 1,000 tons of plutonium waste by this process as of August 19, 1970.

  3. Preparation of fluorescent polyaniline nanoparticles in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Kleber G. B. [Universidade Federal de Pernambuco, Departamento de Engenharia Mecanica (Brazil); Melo, Etelino F. de [Universidade Federal de Pernambuco, Departamento de Quimica Fundamental (Brazil); Andrade, Cesar A. S. [Universidade Federal de Pernambuco, Departamento de Bioquimica (Brazil); Melo, Celso P. de, E-mail: celso@df.ufpe.br [Universidade Federal de Pernambuco, Departamento de Fisica (Brazil)

    2013-01-15

    We report the synthesis of stable polyaniline nanoparticles (PANI{sub N}Ps) based on the chemical oxidative polymerization of aniline in aqueous solutions of surfactants. Surfactants of three different types-cationic (dodecyltrimethylammonium bromide-DTAB), anionic (sodium dodecyl sulfate-SDS), and non-ionic (Triton X-405-TX-405)-were used. The resulting PANI{sub N}Ps{sub s}urfactant samples were characterized through UV-Vis, fluorescence and Fourier transform infrared spectroscopies, and scanning electronic microscopy (SEM). We have verified that the color of the PANI{sub N}Ps{sub s}urfactant dispersions is affected by a change in the pH of the solution. The PANI-NPs{sub s}urfactant colloidal suspensions in aqueous solution present a surprising high fluorescence quantum yield value (ranging from 1.9 Multiplication-Sign 10{sup -3} to 6.9 Multiplication-Sign 10{sup -3}) that can be controlled as a function of the pH, a fact that we associate to the corresponding protonation degree of the PANI polymeric chains. We suggest that these fluorescent nanocomposites can find important technological applications in different areas such as organic light emitting devices, biosensors, and pigments for coatings.

  4. Preparation of fluorescent polyaniline nanoparticles in aqueous solutions

    International Nuclear Information System (INIS)

    Alves, Kleber G. B.; Melo, Etelino F. de; Andrade, César A. S.; Melo, Celso P. de

    2013-01-01

    We report the synthesis of stable polyaniline nanoparticles (PANI N Ps) based on the chemical oxidative polymerization of aniline in aqueous solutions of surfactants. Surfactants of three different types—cationic (dodecyltrimethylammonium bromide—DTAB), anionic (sodium dodecyl sulfate—SDS), and non-ionic (Triton X-405–TX-405)—were used. The resulting PANI N Ps s urfactant samples were characterized through UV–Vis, fluorescence and Fourier transform infrared spectroscopies, and scanning electronic microscopy (SEM). We have verified that the color of the PANI N Ps s urfactant dispersions is affected by a change in the pH of the solution. The PANI-NPs s urfactant colloidal suspensions in aqueous solution present a surprising high fluorescence quantum yield value (ranging from 1.9 × 10 −3 to 6.9 × 10 −3 ) that can be controlled as a function of the pH, a fact that we associate to the corresponding protonation degree of the PANI polymeric chains. We suggest that these fluorescent nanocomposites can find important technological applications in different areas such as organic light emitting devices, biosensors, and pigments for coatings.

  5. Sorption of ochratoxin A from aqueous solutions using β-cyclodextrin-polyurethane polymer.

    Science.gov (United States)

    Appell, Michael; Jackson, Michael A

    2012-02-01

    The ability of a cyclodextrin-polyurethane polymer to remove ochratoxin A from aqueous solutions was examined by batch rebinding assays. The results from the aqueous binding studies were fit to two parameter models to gain insight into the interaction of ochratoxin A with the nanosponge material. The ochratoxin A sorption data fit well to the heterogeneous Freundlich isotherm model. The polymer was less effective at binding ochratoxin A in high pH buffer (9.5) under conditions where ochratoxin A exists predominantly in the dianionic state. Batch rebinding assays in red wine indicate the polymer is able to remove significant levels of ochratoxin A from spiked solutions between 1-10 μg·L(-1). These results suggest cyclodextrin nanosponge materials are suitable to reduce levels of ochratoxin A from spiked aqueous solutions and red wine samples.

  6. Study of colloidal properties of natural and Al-pillared smectite and removal of copper ions from an aqueous solution.

    Science.gov (United States)

    Sartor, Lucas Resmini; de Azevedo, Antonio Carlos; Andrade, Gabriel Ramatis Pugliese

    2015-01-01

    In this study, an Al-pillared smectite was synthesized and changes in its colloidal properties were investigated. The pillaring solution was prepared by mixing 0.4 mol L(-1) NaOH and 0.2 mol L(-1) AlCl3.6H2O solutions. Intercalated clays were heated to obtain the pillared clay, and X-ray diffractometry (XRD), X-ray fluorescence (XRF), Fourier transform infrared (FTIR) spectroscopy and N2 sorption/desorption isotherms analysis were done to characterize the changes in clay properties. Moreover, adsorption experiments were carried out in order to evaluate the capacity of the pillared clays to remove Cu2+ from an aqueous solution and to characterize the interaction between adsorbent and adsorbate. The results indicate that the natural clay has a basal spacing of 1.26 nm, whereas the pillared clays reached 1.78 nm (500°C) and 1.80 nm (350°C) after calcination. XRF analysis revealed an increase in the Al3+ in the pillared clay as compared to the natural clay. The surface area and pore volume (micro and mesoporous) were higher for the pillared clays. Experimental data from the adsorption experiment were fit to Langmuir and Freundlich and Temkin adsorption models, and the former one was the best fit (highest r2 value) for all the clays and lower standard deviation (Δg%) for the natural clay. On the other hand, the Temkin model exhibited Δg% value lower for the pillared clays. Thermodynamics parameters demonstrate that the Cu2+ adsorption process is spontaneous for all the clays, but with higher values for the pillared materials. In addition, application of the Dubinin-Radushkevich model revealed that the bond between the metal and the clay are weak, characterizing a physisorption.

  7. Extended UNIQUAC model for thermodynamic modeling of CO2 absorption in aqueous alkanolamine solutions

    DEFF Research Database (Denmark)

    Faramarzi, Leila; Kontogeorgis, Georgios; Thomsen, Kaj

    2009-01-01

    The extended UNIQUAC model [K. Thomsen, R Rasmussen, Chem. Eng. Sci. 54 (1999) 1787-1802] was applied to the thermodynamic representation of carbon dioxide absorption in aqueous monoethanolamine (MEA), methyldiethanolamine (MDEA) and varied strength mixtures of the two alkanolamines (MEA-MDEA). F......The extended UNIQUAC model [K. Thomsen, R Rasmussen, Chem. Eng. Sci. 54 (1999) 1787-1802] was applied to the thermodynamic representation of carbon dioxide absorption in aqueous monoethanolamine (MEA), methyldiethanolamine (MDEA) and varied strength mixtures of the two alkanolamines (MEA......) are included in the parameter estimation process. The previously unavailable standard state properties of the alkanolamine ions appearing in this work, i.e. MEA protonate, MEA carbamate and MDEA protonate are determined. The concentration of the species in both MEA and MDEA solutions containing CO2...

  8. Removal of Hexavalent Chromium from Aqueous Solutions using ...

    African Journals Online (AJOL)

    The hexavalent chromium exists in aquatic media as water soluble complex anions and persist. These are concentrated in industrial waste water especially from the tannery industries and release of effluents from industries adversely affects the environment. The removal of heavy metals from aqueous solutions is carried ...

  9. Forced Spreading of Aqueous Solutions on Zwitterionic Sulfobetaine Surfaces for Rapid Evaporation and Solute Separation.

    Science.gov (United States)

    Wu, Cyuan-Jhang; Singh, Vickramjeet; Sheng, Yu-Jane; Tsao, Heng-Kwong

    2017-08-01

    Solute separation of aqueous mixtures is mainly dominated by water vaporization. The evaporation rate of an aqueous drop grows with increasing the liquid-gas interfacial area. The spontaneous spreading behavior of a water droplet on a total wetting surface provides huge liquid-gas interfacial area per unit volume; however, it is halted by the self-pinning phenomenon upon addition of nonvolatile solutes. In this work, it is shown that the solute-induced self-pinning can be overcome by gravity, leading to anisotropic spreading much faster than isotropic spreading. The evaporation rate of anisotropic spreading on a zwitterionic sulfobetaine surface is 25 times larger as that on a poly(methyl methacrylate) surface. Dramatic enhancement of evaporation is demonstrated by simultaneous formation of fog atop liquid film. During anisotropic spreading, the solutes are quickly precipitated out within 30 s, showing the rapid solute-water separation. After repeated spreading process for the dye-containing solution, the mean concentration of the collection is doubled, revealing the concentration efficiency as high as 100%. Gravity-enhanced spreading on total wetting surfaces at room temperature is easy to scale-up with less energy consumption, and thus it has great potentials for the applications of solute separation and concentration.

  10. PMMA-g-OEtOx Graft Copolymers: Influence of Grafting Degree and Side Chain Length on the Conformation in Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Irina Muljajew

    2018-03-01

    Full Text Available Depending on the degree of grafting (DG and the side chain degree of polymerization (DP, graft copolymers may feature properties similar to statistical copolymers or to block copolymers. This issue is approached by studying aqueous solutions of PMMA-g-OEtOx graft copolymers comprising a hydrophobic poly(methyl methacrylate (PMMA backbone and hydrophilic oligo(2-ethyl-2-oxazoline (OEtOx side chains. The graft copolymers were synthesized via reversible addition-fragmentation chain transfer (RAFT copolymerization of methyl methacrylate (MMA and OEtOx-methacrylate macromonomers of varying DP. All aqueous solutions of PMMA-g-OEtOx (9% ≤ DG ≤ 34%; 5 ≤ side chain DP ≤ 24 revealed lower critical solution temperature behavior. The graft copolymer architecture significantly influenced the aggregation behavior, the conformation in aqueous solution and the coil to globule transition, as verified by means of turbidimetry, dynamic light scattering, nuclear magnetic resonance spectroscopy, and analytical ultracentrifugation. The aggregation behavior of graft copolymers with a side chain DP of 5 was significantly affected by small variations of the DG, occasionally forming mesoglobules above the cloud point temperature (Tcp, which was around human body temperature. On the other hand, PMMA-g-OEtOx with elongated side chains assembled into well-defined structures below the Tcp (apparent aggregation number (Nagg = 10 that were able to solubilize Disperse Orange 3. The thermoresponsive behavior of aqueous solutions thus resembled that of micelles comprising a poly(2-ethyl-2-oxazoline (PEtOx shell (Tcp > 60 °C.

  11. Aqueous solution of basic fuchsin as food irradiation dosimeter

    International Nuclear Information System (INIS)

    Khan, H.M.; Naz, S.

    2006-01-01

    Dosimetric characterization of aqueous solution of basic fuchsin has been studied spectrophotometrically for the possible application in the low-dose food irradiation dosimetry. Absorption spectra of unirradiated and irradiated solutions were determined and decrease in the absorption with the radiation dose was noted down. Radiation-induced bleaching of the dye was measured at wavelengths of maximum absorption λ max (540nm) as well as 510, 460 and 400 nm wavelengths. At all these wavelengths, the decrease in the absorbance of the dosimeter was linear with respect to the absorbed dose from 0.05 to 0.6 kGy. The stability of dosimetric solution during the post-irradiation storage in the dark at room temperature showed that after initial bleaching during first eight days, the response was almost stable for about 34 days. The effect of different light and temperature conditions also showed that the response gradually decreased during the storage period of 34 days, which shows that the basic fuchsin dye is photosensitive as well as thermally sensitive. The possibility of using aqueous solution of basic fuchsin as food irradiation dosimeter will be discussed. (authors)

  12. Adsorption of Cu 2+ , As 3+ and Cd 2+ ions from aqueous solution ...

    African Journals Online (AJOL)

    The adsorption of Cu2+, Cd2+ and As3+ ions on eggshell from aqueous solution was studied under batch conditions at 30, 40, 50 and 60oC and concentrations of 10, 20, 30, 60 and 80 mg/l. The partition coefficient for the ions between aqueous solution and chicken eggshell increased with time and with increase in the ...

  13. Experimental measurements of U24Py nanocluster behavior in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, Shannon L.; Szymanowski, Jennifer E.S.; Fein, Jeremy B. [Univ. of Notre Dame, IN (United States). Department of Civil and Environmental Engineering and Earth Sciences; Dembowski, Mateusz [Univ. of Notre Dame, IN (United States). Department of Chemistry and Biochemistry; Burns, Peter C. [Univ. of Notre Dame, IN (United States). Department of Civil and Environmental Engineering and Earth Sciences; Univ. of Notre Dame, IN (United States). Department of Chemistry and Biochemistry

    2016-07-01

    Uranyl peroxide nanoclusters may impact the mobility and partitioning of uranium at contaminated sites and could be used in the isolation of uranium during the reprocessing of nuclear waste. Their behavior in aqueous systems must be better understood to predict the environmental fate of uranyl peroxide nanoclusters and for their use in engineered systems. The aqueous stability of only one uranyl peroxide nanocluster, U60 (K{sub 16}Li{sub 44}[UO{sub 2}(O{sub 2})OH]{sub 60}), has been studied to date [Flynn, S. L., Szymanowski, J. E. S., Gao, Y., Liu, T., Burns, P. C., Fein, J. B.: Experimental measurements of U60 nanocluster stability in aqueous solution. Geochemica et Cosmochimica Acta 156, 94-105 (2015)]. In this study, we measured the aqueous stability of a second uranyl peroxide nanocluster, U24Py (Na{sub 30}[(UO{sub 2}){sub 24}(O{sub 2}){sub 24}(HP{sub 2}O{sub 7}){sub 6}(H{sub 2}P{sub 2}O{sub 7}){sub 6}]), in batch systems as a function of time, pH, and nanocluster concentration, and then compared the aqueous behavior of U24Py to U60 to determine whether the size and morphology differences result in differences in their aqueous behaviors. Systems containing U24Py nanoclusters took over 30 days to achieve steady-state concentrations of monomeric U, Na, and P, illustrating slower reaction kinetics than parallel U60 systems. Furthermore, U24Py exhibited lower stability in solution than U60, with an average of 72% of the total mass in each nanocluster suspension being associated with the U24Py nanocluster, whereas 97% was associated with the U60 nanocluster in parallel experiments [Flynn, S. L., Szymanowski, J. E. S., Gao, Y., Liu, T., Burns, P. C., Fein, J. B.: Experimental measurements of U60 nanocluster stability in aqueous solution. Geochemica et Cosmochimica Acta 156, 94-105 (2015)]. The measurements from the batch experiments were used to calculate ion activity product (IAP) values for the reaction between the U24Py nanocluster and its constituent monomeric

  14. Removal of boron from aqueous solution using cryptocrystalline magnesite

    CSIR Research Space (South Africa)

    Masindi, Vhahangwele

    2016-05-01

    Full Text Available of Water Reuse and Desalination Removal of boron from aqueous solution using cryptocrystalline magnesite Vhahangwele Masindi and Mugera W. Gitari Abstract The present study aimed to evaluate the efficiency of using cryptocrystalline magnesite...

  15. Theoretical approach to the destruction or sterilization of drugs in aqueous solution

    International Nuclear Information System (INIS)

    Slegers, Catherine; Tilquin, Bernard

    2005-01-01

    Two novel applications in the radiation processing of aqueous solutions of drugs are the sterilization of injectable drugs and the decontamination of hospital wastewaters by ionizing radiation. The parameters influencing the destruction of the drug in aqueous solutions are studied with a computer simulation program. This theoretical approach has revealed that the dose rate is the most important parameter that can be easily varied in order to optimize the destruction or the protection of the drug

  16. Study of the Conformational State of Non-Cross-Linked and Cross-Linked Poly(alkylmethyldiallylammonium chlorides) in Aqueous Solution by Fluorescence Probing

    NARCIS (Netherlands)

    Wang, Guang-Jia; Engberts, Jan B.F.N.

    The aggregation behaviour of novel non-cross-linked and cross-linked poly(alkylmethyldiallylammonium chlorides) in aqueous solutions has been investigated by fluorescence spectroscopy using pyrene as a probe. These copolymers were found to exhibit similar aggregate properties as the corresponding

  17. Aqueous solution dispersement of carbon nanotubes

    Science.gov (United States)

    Kim, Jae-Woo (Inventor); Park, Cheol (Inventor); Choi, Sang H. (Inventor); Lillehei, Peter T. (Inventor); Harrison, Joycelyn S. (Inventor)

    2011-01-01

    Carbon nanotubes (CNTs) are dispersed in an aqueous buffer solution consisting of at least 50 weight percent water and a remainder weight percent that includes a buffer material. The buffer material has a molecular structure defined by a first end, a second end, and a middle disposed between the first and second ends. The first end is a cyclic ring with nitrogen and oxygen heteroatomes, the middle is a hydrophobic alkyl chain, and the second end is a charged group.

  18. Experimental measurements of U60 nanocluster stability in aqueous solution

    Science.gov (United States)

    Flynn, Shannon L.; Szymanowski, Jennifer E. S.; Gao, Yunyi; Liu, Tianbo; Burns, Peter C.; Fein, Jeremy B.

    2015-05-01

    In this study, the aqueous behavior of isolated U60 nanoclusters (K16Li25[UO2(O2)OH]60)-19 was studied under several pH conditions and nanocluster concentrations to determine if the nanoclusters exhibit solid phase buffering behavior or if they exhibit behavior more like aqueous complexes. U60 is a cage cluster consisting of 60 (UO2)(O2)2(OH)2 uranyl polyhedral which share OH and O2 groups with their neighboring uranyl polyhedral, resulting in negatively charged cage clusters whose charge is at least partially offset by K+ and Li+ in the aqueous phase. Batch experiments to monitor nanocluster stability were conducted for 16 days at pH 7.5, 8.0 and 8.5 at nanocluster suspension concentrations of 1.4, 2.8 and 6.0 g/L. The aqueous concentrations of U, Li, and K, determined after 10 kDa molecular weight filtration, achieved steady-state with the nanoclusters within 24 h. The steady-state aqueous U, Li, and K concentrations were independent of solution pH, however they increased with increasing nanocluster concentration, indicating that the nanoclusters do not buffer the aqueous activities as a bulk solid phase would, but exhibit behavior that is more characteristic of dissolved aqueous complexes. The ion activity product (I.A.P.) value was calculated using two approaches: (1) treating the nanoclusters as a solid phase with an activity of one, and (2) treating the nanoclusters as aqueous complexes with a non-unit activity equal to their concentration in solution. The I.A.P. values that were calculated with non-unit activity for the nanoclusters exhibited significantly less variation as a function of nanocluster concentration compared to the I.A.P. values calculated with a nanocluster activity of one. The results yield a calculated log dissociation constant for the U60 nanoclusters of 9.2 + 0.2/-0.3 (1σ). Our findings provide a better understanding of the thermodynamic stability and behavior of U60 nanoclusters in aqueous systems, and can be used to estimate the

  19. Effect of pressure on the solution structure and hydrogen bond properties of aqueous N-methylacetamide

    International Nuclear Information System (INIS)

    Sarma, Rahul; Paul, Sandip

    2012-01-01

    Highlights: ► NMA molecules are associated mostly through their hydrophobic methyl groups. ► High pressure reduces association propensity causing dispersion of these moieties. ► Orientational polarization of vicinal water molecules near O and H atoms of NMA. ► NMA prefers to be a H-bond acceptor rather than a donor in interaction with water. ► Energy of these hydrogen bonds reduces slightly at high pressure. -- Abstract: Effects of high pressure on hydrophobic and hydrogen bonding interactions are investigated by employing molecular dynamics (MD) simulations of aqueous N-methylacetamide (NMA) solutions. Such systems are of interest mainly because high pressure causes protein denaturation and NMA is a computationally effective model to understand the atomic-level picture of pressure-induced structural transitions of protein. Simulations are performed for five different pressure values ranging from 1 atm to 8000 atm. We find that NMA molecules are associated mostly through their hydrophobic methyl groups and high pressure reduces this association propensity, causing dispersion of these moieties. At high pressure, structural void decreases and the packing efficiency of water molecules around NMA molecules increases. Hydrogen bond properties calculations show favorable NMA–NMA hydrogen bonds as compared to those of NMA–water hydrogen bonds and preference of NMA to be a hydrogen bond acceptor rather than a donor in interaction with water.

  20. Actinide removal from aqueous solution with activated magnetite

    International Nuclear Information System (INIS)

    Kochen, R.L.; Thomas, R.L.

    1987-01-01

    An actinide aqueous waste treatment process using activated magnetite has been developed at Rocky Flats. The use and effectiveness of various magnetites in lowering actinide concentrations in aqueous solution are described. Experiments indicate that magnetite particle size and pretreatment (activation of the magnetite surface with hydroxyl ions greatly influence the effective use of magnetite as an actinide adsorbent. With respect to actinide removal, Ba(OH) 2 -activated magnetite was more effective over a broader pH range than was NaOH-activated magnetite. About 50% less Ba(OH) 2 -activated magnetite was required to lower plutonium concentration from 10 -4 to 10 -8 g/l. 7 refs., 8 tabs

  1. Degradation of Para-Phenylenediamine in Aqueous Solution by ...

    African Journals Online (AJOL)

    In this research Photo-Fenton Oxidation of Para-Phenylenediamine (PPD) in aqueous solution by UV/Fenton's reagent (Fe2+ and H2O2) was investigated. ... lower concentration of Phenylenediamines and UV-C assisted photo-Fenton showed that the photo-Fenton process was very effective than the normal Fenton process ...

  2. Radiolysis of Aqueous Benzene Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, H

    1964-05-15

    Aerated and deaerated aqueous solutions of benzene have been irradiated with {sup 60}Co {gamma}-rays. The products of radiolysis in deaerated, unbuffered or acid, solutions were phenol, biphenyl, hydrogen and in acid solutions also hydrogen peroxide with the following yields: G(phenol) = 0. 37 (0. 37), G(biphenyl) = 1.3 (1.7), G(H{sub 2}) = 0.44 (0. 43) and G(H{sub 2}O{sub 2}) = 0 (0.60), the figures in brackets giving the results for acid solutions. The results are shown to agree with the conclusion that k(e{sup -}{sub aq} + H{sub 2}O{sub 2}) >> k(H + H{sub 2}O{sub 2}). Furthermore, the results indicate that a competition takes place between the reactions: 2 C{sub 6}H{sub 6}OH {center_dot} -> dimer -> biphenyl. C{sub 6}H{sub 7} {center_dot} + C{sub 6}H{sub 6}OH {center_dot} -> dimer -> biphenyl. The yields in aerated, unbuffered or acid, solutions were: G(phenol) = 2.1 (2.3), G(biphenyl) = 0 (0), and G(H{sub 2}O{sub 2}) = 2.2 (3.1), the figures in brackets being valid for acid solutions. The ratio k(H + C{sub 6}H{sub 6})/k(H + O{sub 2}) was 1.4x10{sup -2}. The results indicate that peroxides, or more probably hydroperoxides, take part in the reactions. After the addition of Fe{sup 2+} or Fe{sup 3+} to aerated acid solutions G(phenol) was increased to 6.6 and 3.4 respectively. Oxygen was consumed more rapidly in the presence of Fe. Reaction mechanisms are discussed.

  3. Corrosion resistance of amorphous and crystalline Pd40Ni40P20 alloys in aqueous solutions

    DEFF Research Database (Denmark)

    Wu, Y.F.; Chiang, Wen-Chi; Chu, J.

    2006-01-01

    The corrosion behaviors of amorphous and crystalline Pd40Ni40P20 alloys in various aqueous solutions are reported in this paper. The corrosion resistance of crystalline (annealed) Pd40Ni40P20 is better than that of amorphous Pd40Ni40P20 in various corrosive solutions, due to crystalline Pd40Ni40P20...... and mainly consists of inert Pd5P2, NI3P, Ni2Pd2P and noble Pd phases. These inert and noble properties result in a higher corrosion resistance in crystalline Pd40Ni40P20....

  4. Stabilizers of edaravone aqueous solution and their action mechanisms. 1. Sodium bisulfite

    OpenAIRE

    Tanaka, Masahiko; Sugimura, Natsuhiko; Fujisawa, Akio; Yamamoto, Yorihiro

    2017-01-01

    Edaravone (3-methyl-1-phenyl-2-pyrazolin-5-one) has been used as a free radical scavenging drug for the treatment of acute ischemic stroke in Japan since 2001. Edaravone is given to patients intravenously; therefore, it is distributed in the form of an aqueous solution. However, aqueous solutions of edaravone are very unstable because it is present as edaravone anion, which is capable of transferring an electron to free radicals including oxygen, and becomes edaravone radical. We observed the...

  5. Degradation of alachlor in aqueous solution by using hydrodynamic cavitation.

    Science.gov (United States)

    Wang, Xikui; Zhang, Yong

    2009-01-15

    The degradation of alachlor aqueous solution by using hydrodynamic cavitation was systematically investigated. It was found that alachlor in aqueous solution can be deomposed with swirling jet-induced cavitation. The degradation can be described by a pseudo-first-order kinetics and the degradation rate was found to be 4.90x10(-2)min(-1). The effects of operating parameters such as fluid pressure, solution temperature, initial concentration of alachlor and medium pH on the degradation rates of alachlor were also discussed. The results showed that the degradation rates of alachlor increased with increasing pressure and decreased with increasing initial concentration. An optimum temperature of 40 degrees C existed for the degradation rate of alachlor and the degradation rate was also found to be slightly depend on medium pH. Many degradation products formed during the process, and some of them were qualitatively identified by GC-MS.

  6. The effect of gamma irradiation on rice protein aqueous solution

    Science.gov (United States)

    Baccaro, Stefania; Bal, Oya; Cemmi, Alessia; Di Sarcina, Ilaria

    2018-05-01

    The use of proteins as natural biopolymers are sensibly increasing in several application fields such as food industry, packaging and environment protection. In particular, rice proteins (RP) present good nutritional, hypoallergenic and healthful properties very interesting for human consumption. Since ionizing radiation can be successfully applied on protein containing systems involved in different industrial processes, this work aims to determine the effect of gamma radiation on 5 wt%-7.5 wt% RP aqueous solutions in a wide range of absorbed doses up to around 40 kGy. The changes of RP secondary and tertiary structures and their chemical composition were followed by UV-VIS absorbance spectroscopy, luminescence analysis and pH measurements. The experimental data showed the occurrence of the unfolding of RP chains with the increase of the absorbed dose and the formation of new molecules, due to the reaction among tryptophane and tyrosine amino acids and the radical species induced by gamma radiation. The results are also confirmed by the modification of the pH values measured for the irradiated solutions.

  7. Solubility and viscosity for CO_2 capture process using MEA promoted DEAE aqueous solution

    International Nuclear Information System (INIS)

    Fu, Dong; Wang, LeMeng; Zhang, Pan; Mi, ChenLu

    2016-01-01

    Highlights: • Solubility of CO_2 in MEA promoted DEAE aqueous solution was measured. • Mass fraction and temperature dependences of solubility were illustrated. • Viscosities of carbonated MEA–DEAE solutions were measured and calculated. • Temperature, mass fraction and CO_2 loading dependences of viscosity were illustrated. - Abstract: The saturated solubility of CO_2 in monoethanolamine (MEA) promoted 2-diethylaminoethanol (DEAE) aqueous solution was investigated at temperatures ranging from (303.2 to 323.2) K. The mass fraction and temperature dependences of the saturated solubility and CO_2 loading are illustrated. The viscosities of both CO_2-unloaded and CO_2-loaded DEAE–MEA aqueous solutions were measured and then calculated by using the Weiland equation. The effects of temperature, mass fraction and CO_2 loading on viscosities are demonstrated.

  8. Radiation resistance of organic azo dyes in aqueous solutions

    International Nuclear Information System (INIS)

    Khabarov, V.N.; Kozlov, L.L.

    1987-01-01

    The resistance to the action of the ionizing radiation of aqueous and aqueous-alcoholic solutions of organic mono- and diazo dyes was studied. The radiation chemical yield of decolorization of the dye, determined from the kinetic decolorization curves served as a quantitative criterion of the radiation resistance. The influence of pH, addition of ethanol, hydroquinone, thiourea, glucose and oxygen on the radiation resistance of the azo dyes was studied. An attempt was made to relate the efficiency of radiation decolorization to the chemical nature of the dye

  9. DETERMINING PARAMETERS OF THE DIELECTRIC FUNCTION OF A SUBSTANCE IN AQUEOUS SOLUTION BY SELF-REFERENCED REFLECTION THZ SPECTROSCOPY

    DEFF Research Database (Denmark)

    2008-01-01

    Method and apparatus for determining dielectric function of liquid solutions and thereby concentrations of substances in aqueous solution or the volatile/non-volatile nature of the liquid by self-referenced reflection THz spectroscopy. Having the aqueous solution in any container with a window al....... The invention is particularly useful for determining alcohol (ethanol) content in aqueous solution containing other substances and particles....

  10. An introduction to radiation induced degradation of biological molecules in aqueous solutions

    International Nuclear Information System (INIS)

    Lal, Manohar

    1991-01-01

    Radiation chemistry of aqueous systems is the chemistry of H, OH, e aq - , H 3 O + and H 2 O * formed when a solute in aqueous solutions is exposed to ionising radiation. The pulse radiolysis technique has helped in the production, the detection and understanding of the reactions of primary species with solutes. A great deal of data on radiation biochemical studies e.g. degradation of DNA, its constituents and their protection, radiation protection and sensitisation, generation of superoxide ion and their reactions has already been reported but a great deal still needs to be done for the understanding of radiation biology. (author). 12 refs

  11. Ammonia complexes of metals in aqueous solutions with high concentrations of ammonia

    International Nuclear Information System (INIS)

    Padar, T.G.; Novikov, L.K.; Stupko, T.V.; Isaev, I.D.; Pashkov, G.L.; Mironov, V.E.

    1991-01-01

    Potentiometric method, glass electrodes and Bierrum function were used to study the formation of ammonia complexes of magnesium, calcium, cadmium, zinc, copper(2) and silver in 2.0 mol/dm 3 aqueous solutions of ammonia nitrate with 0-18 mol/dm 3 ammonia concentrations at 25.0 deg C. Step constants of stability of studied complexes were calculated and their compositions were determined with account of nonideal character of aqueous-salt solutions with ammonia concentrations above 1.0 mol/dm 3 . Values of correction effects on salting out ammonia action for Bierrum function in solutions with 1.0-18 mol/dm 3 ammonia concentrations were found

  12. Efficient removal of Co(II) from aqueous solution by titanate sodium nanotubes

    Institute of Scientific and Technical Information of China (English)

    Dong-Mei Li; Ning Liu; Fei-Ze Li; Jia-Li Liao; Ji-Jun Yang; Bing Li; Yun-Ming Chen; Yuan-You Yang; Jin-Song Zhang; Jun Tang

    2016-01-01

    In this paper, a novel material for Co(II) adsorption, titanate sodium nanotubes (Na2Ti2O5-NTs) were synthesized and characterized, and then they were used to remove Co(II) from aqueous solution and compared with titanic acid nanotubes (H2Ti2O5-NTs) and potassium hexatitanate whiskers (K2Ti6O13). The results showed that the adsorption of Co(II) on the materials was dependent on pH values and was a spontaneous, endothermic process. Specifically, Na2Ti2O5-NTs exhibited much more efficient ability to adsorb Co(II) from aqueous solution, with the maximum adsorption capacity of 85.25 mg/g. Furthermore, Na2Ti2O5-NTs could selectively adsorb Co(II) from aque-ous solution containing coexisting ions (Na+, K+, Mg2+, and Ca2+). The results suggested that Na2Ti2O5-NTs were potential effective adsorbents for removal of Co(II) or cobalt-60 from wastewater.

  13. A thermodynamic study of glucose and related oligomers in aqueous solution: Vapor pressures and enthalpies of mixing

    DEFF Research Database (Denmark)

    Cooke, S.A.; Jonsdottir, Svava Osk; Westh, Peter

    2002-01-01

    Vapor pressures above aqueous solutions of glucose and maltose at both 298.06 K and 317.99 K and vapor pressures above aqueous solutions of cellobiose, maltotriose, maltotetraose, and maltopentaose at 317.99 K have been measured. The excess enthalpies have been recorded for all of the above-menti...... in aqueous solution. This so-called transference principle is found to be of interest in furthering the discussion concerning the applicability of lattice-based models for solution theory....

  14. Hg(II) removal from aqueous solutions by bacillus subtilis biomass

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xue Song; Li, Fei Yan; He, Wen; Miao, Hua Hua [Department of Chemical Engineering, Huaihai Institute of Technology, Lianyungang (China)

    2010-01-15

    The biosorption of Hg(II) from aqueous solutions using Bacillus subtilis biomass was investigated in this study. The adsorbent was characterized by FTIR. Various factors including solution pH, initial concentration of Hg(II), contact time, reaction temperature and ionic strength were taken into account and promising results were obtained. An initial solution pH of 5.0 was most favorable for Hg(II) removal. The kinetic data was also analyzed using pseudo first order and pseudo second order equations. The results suggested that Hg(II) bioadsorption was best represented by the pseudo second order equation. Freundlich, Langmuir and Langmuir-Freundlich isotherms for the present systems were analyzed. The most satisfactory interpretation for the equilibrium data at different temperatures was given by the Langmuir-Freundlich isotherm. The effect of ionic strength on bioadsorption was significant. Bacillus subtilis biomass could serve as low cost adsorbent to remove Hg(II) from aqueous solutions, especially at lower concentrations of Hg(II) (<20 mg Hg/L). (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  15. Deacidification of oils and fats of biological origine by aqueous solutions of tertiary amines*

    Directory of Open Access Journals (Sweden)

    Peter Siegfried

    2001-01-01

    Full Text Available Deacidification of triacylglycerols by extraction is investigated using aqueous solutions of amines as extractants. Tertiary amines with boiling points ranging between 100° and 170°C, such as 2-methylamino-diethanol, 2-dimethylamino-ethanol, 4-methylmorpholine, 1-dimethylamino-2-propanol etc. were found to be suitable substances. Especially the deacidification by aqueous solutions of 2-dimethylamino-ethanol (DMAE was amply investigated as it is used as an active agent in remedies. Amazingly gelatinous soap stocks are not formed, when the concentration of DMAE exceeds 20% if the free fatty acid content of the oil is below 15%. Two liquid phases are formed in systems composed of triacylglyceroles and aqueous solutions containing 20 to 80% DMAE. Palm oil containing 4.3 wt.% free fatty acids was mixed with an equal amount of an aqueous solution of 30 wt.% DMAE at 60°C. In equilibrium an extract containing 86 wt.% free fatty acids (solvents deducted and a raffinate of 0.09 wt.% free fatty acids are obtained. Loss of neutral oil being 0.7 wt.%.

  16. Radiolysis of anthraquinone dyes in aqueous solutions

    International Nuclear Information System (INIS)

    Vysotskaya, N.A.; Bortun, L.N.; Ogurtsov, N.A.; Migdalovich, E.A.; Revina, A.A.; Volodko, V.V.; AN SSSR, Moscow. Inst. Ehlektrokhimii)

    1986-01-01

    The commercial anthraquinone dyes (Dark Blue, Light Blue, Green) in aqueous solutions were shown to be decoloured and degrade under the action of ionizing radiation. The degree of decolouration and degradation of aromatic rings was found to increase in presence of oxygen. Hydroxyl radicals were shown to play the key role in the degradation of the dyes under irradiation. The radiolysis intermediate products were studied using the pulse radiolysis technique. (author)

  17. Ion spatial distributions at the liquid-vapor interface of aqueous potassium fluoride solutions

    Energy Technology Data Exchange (ETDEWEB)

    Brown, M A; D' Auria, R; Kuo, I W; Krisch, M J; Starr, D E; Bluhm, H; Tobias, D J; Hemminger, J C

    2008-04-23

    X-ray photoemission spectroscopy operating under ambient pressure conditions is used to probe ion distributions throughout the interfacial region of a free-flowing aqueous liquid micro-jet of 6 M potassium fluoride. Varying the energy of the ejected photoelectrons by carrying out experiments as a function of x-ray wavelength measures the composition of the aqueous-vapor interfacial region at various depths. The F{sup -} to K{sup +} atomic ratio is equal to unity throughout the interfacial region to a depth of 2 nm. The experimental ion profiles are compared with the results of a classical molecular dynamics simulation of a 6 M aqueous KF solution employing polarizable potentials. The experimental results are in qualitative agreement with the simulations when integrated over an exponentially decaying probe depth characteristic of an APPES experiment. First principles molecular dynamics simulations have been used to calculate the potential of mean force for moving a fluoride anion across the air-water interface. The results show that the fluoride anion is repelled from the interface, and this is consistent with the depletion of F{sup -} at the interface revealed by the APPES experiment and polarizable force field-based molecular dynamics simulation. Together, the APPES and MD simulation data provide a detailed description of the aqueous-vapor interface of alkali fluoride systems. This work offers the first direct observation of the ion distribution at a potassium fluoride aqueous solution interface. The current experimental results are compared to those previously obtained for saturated solutions of KBr and KI to underscore the strong difference in surface propensity between soft/large and hard/small halide ions in aqueous solution.

  18. Opto-electrochemical spectroscopy of metals in aqueous solutions

    International Nuclear Information System (INIS)

    Habib, K.

    2016-01-01

    In the present investigation, holographic interferometry was utilized for the first time to determine the rate change of the electrical resistance of aluminium samples during the initial stage of anodisation processes in aqueous solution. In fact, because the resistance values in this investigation were obtained by holographic interferometry, electromagnetic method rather than electronic method, the abrupt rate change of the resistance was called electrical resistance–emission spectroscopy. The anodisation process of the aluminium samples was carried out by electrochemical impedance spectroscopy (EIS) in different sulphuric acid concentrations (1.0%–2.5% H 2 SO 4 ) at room temperature. In the meantime, the real time holographic interferometry was used to determine the difference between the electrical resistance of two subsequent values, dR, as a function of the elapsed time of the EIS experiment for the aluminium samples in 1.0%, 1.5%, 2.0%, and 2.5% H 2 SO 4 solutions. The electrical resistance–emission spectra of the present investigation represent a detailed picture of not only the rate change of the electrical resistance throughout the anodisation processes but also the spectra represent the rate change of the growth of the oxide films on the aluminium samples in different solutions. As a result, a new spectrometer was developed based on the combination of the holographic interferometry and electrochemical impedance spectroscopy for studying in situ the electrochemical behavior of metals in aqueous solutions.

  19. Extraction of hafnium with chelating agents from aqueous-alcoholic solutions

    International Nuclear Information System (INIS)

    Hala, J.; Prihoda, J.

    1975-01-01

    The extraction was studied of hafnium into solutions of N-benzoyl-N-phenylhydroxylamine, 2-thenoyltrifluoroacetone and di-n-butylphosphoric acid in benzene, toluene, chloroform and tetrachloromethane from aqueous alcoholic solutions with a formal acidity of 2M-HClO 4 . Methyl-, ethyl-, n- and isopropyl- and tert-butyl alcohol were used as organic components in the mixed aqueous-organic phase. In the extraction into N-benzoyl-N-phenylhydroxylamine the presence of the alcohols resulted in synergic effects analogous to the previously described extraction by substituted benzoylpyrazolone. With the other two extractants, the effect of the alcohols was antagonistic, due to the interaction of alcohol or water with the reagent in the organic phase, and to the decrease in the reagent distribution constant. (author)

  20. Origin of supercharging in electrospray ionization of noncovalent complexes from aqueous solution.

    Science.gov (United States)

    Sterling, Harry J; Williams, Evan R

    2009-10-01

    The use of m-nitrobenzyl alcohol (m-NBA) to enhance charging of noncovalent complexes formed by electrospray ionization from aqueous solutions was investigated. Addition of up to 1% m-NBA can result in a significant increase in the average charging of complexes, ranging from approximately 13% for the homo-heptamer of NtrC4-RC (317 kDa; maximum charge state increases from 42+ to 44+) to approximately 49% for myoglobin (17.6 kDa; maximum charge state increases from 9+ to 16+). Charge state distributions of larger complexes obtained from heated solutions to which no m-NBA was added are remarkably similar to those containing small amounts of m-NBA. Dissociation of the complexes through identical channels both upon addition of higher concentrations of m-NBA and heating is observed. These results indicate that the enhanced charging upon addition of m-NBA to aqueous electrospray solutions is a result of droplet heating owing to the high boiling point of m-NBA, which results in a change in the higher-order structure and/or dissociation of the complexes. For monomeric proteins and small complexes, the enhancement of charging is lower for heated aqueous solutions than from solutions with m-NBA because rapid folding of proteins from heated solutions that do not contain m-NBA can occur after the electrospray droplet is formed and is evaporatively cooled.

  1. Lignocellulosic Composites Prepared Utilizing Aqueous Alkaline/Urea Solutions with Cold Temperatures

    Directory of Open Access Journals (Sweden)

    Brent Tisserat

    2018-01-01

    Full Text Available Lignocellulosic composites (LCs were fabricated by partially dissolving cotton to create a matrix that was reinforced with osage orange wood (OOW particles and/or blue agave fibers (AF. LCs were composed of 15–35% cotton matrix and 65–85% OWW/AF reinforcement. The matrix was produced by soaking cotton wool in a cold aqueous alkaline/urea solvent and was stirred for 15 minutes at 350 rpm to create a viscous gel. The gel was then reinforced with lignocellulosic components, mixed, and then pressed into a panel mold. LC panels were soaked in water to remove the aqueous solvent and then oven dried to obtain the final LC product. Several factors involved in the preparation of these LCs were examined including reaction temperatures (−5 to −15°C, matrix concentration (15–35% cotton, aqueous solvent volume (45–105 ml/panel, and the effectiveness of employing various aqueous solvent formulations. The mechanical properties of LCs were determined and reported. Conversion of the cotton into a suitable viscous gel was critical in order to obtain LCs that exhibited high mechanical properties. LCs with the highest mechanical properties were obtained when the cotton wools were subjected to a 4.6% LiOH/15% urea solvent at −12.5°C using an aqueous solvent volume of 60 ml/panel. Cotton wool subjected to excessive cold alkaline solvents volumes resulted in irreversible cellulose breakdown and a resultant LC that exhibited poor mechanical properties.

  2. Experimental data of biomaterial derived from Malva sylvestris and charcoal tablet powder for Hg2+ removal from aqueous solutions

    Directory of Open Access Journals (Sweden)

    Alireza Rahbar

    2016-09-01

    Full Text Available In this experimental data article, a novel biomaterial was provided from Malva sylvestris and characterized its properties using various instrumental techniques. The operating parameters consisted of pH and adsorbent dose on Hg2+ adsorption from aqueous solution using M. sylvestris powder (MSP were compared with charcoal tablet powder (CTP, a medicinal drug. The data acquired showed that M. sylvestris is a viable and very promising alternative adsorbent for Hg2+ removal from aqueous solutions. The experimental data suggest that the MSP is a potential adsorbent to use in medicine for treatment of poisoning with heavy metals; however, the application in animal models is a necessary step before the eventual application of MSP in situations involving humans. Keywords: Adsorption, Biomaterial, Hg2+ ion, Malva sylvestris, Charcoal tablet

  3. [Extraction of lambda-cyhalothrin from aqueous dioxan solutions].

    Science.gov (United States)

    Shormanov, V K; Chigareva, E N; Belousova, O V

    2011-01-01

    The results of extraction of lambda-cigalotrin from dioxan aqueous solutions by hydrophobic organic solvents are presented. It is shown that the degree of extraction depends on the nature of the extractant, the water to dioxan ratio, and saturation of the water-dioxan layer with the electrolyte. The highest efficiency of lambda-cigalotrin extraction was achieved using chlorophorm as a solvent under desalination conditions. The extraction factor was calculated necessary to obtain the desired amount of lambda-cigalotrin from the water-dioxan solution (4:1) with the help of the extractants being used.

  4. NMR study of thermoresponsive block copolymer in aqueous solution

    Czech Academy of Sciences Publication Activity Database

    Spěváček, Jiří; Konefal, Rafal; Čadová, Eva

    2016-01-01

    Roč. 217, č. 12 (2016), s. 1370-1375 ISSN 1022-1352 R&D Projects: GA ČR(CZ) GA15-13853S Institutional support: RVO:61389013 Keywords : aqueous solutions * NMR * NOESY Subject RIV: CD - Macromolecular Chemistry Impact factor: 2.500, year: 2016

  5. DETERMINATION OF CHLORHEXIDINE IN SALIVA AND IN AQUEOUS-SOLUTIONS

    NARCIS (Netherlands)

    de Vries, J.; Ruben, J; Arends, J.

    1991-01-01

    A new method is presented for the determination of chlorhexidine in centrifuged saliva and in aqueous solutions by means of fluorescence spectroscopy. The method relies on complex formation between chlorhexidine and eosin. The fluorescence value of the chlorhexidine-eosin system decreases with

  6. Thermodynamic behavior of erythritol in aqueous solutions and in gelatine gels and its quantification

    International Nuclear Information System (INIS)

    Tyapkova, Oxana; Bader-Mittermaier, Stephanie; Schweiggert-Weisz, Ute

    2013-01-01

    Highlights: • Differential scanning calorimetry as a method to determine erythritol crystallization. • Determination of crystallization using solution enthalpy. • Erythritol crystallization influenced by area of air–water-interfaces. • DSC method is applicable for both aqueous solutions and gels. • Adaption of DSC method to other, more complex food matrices is possible. - Abstract: As crystallization of erythritol can cause a sandy mouth-feel in sugar-free products, strategies to avoid crystallization or adaption of food formulation should be elucidated. However, until now erythritol crystallization was only quantified in aqueous solutions, but not in model food systems. Differential scanning calorimetry (DSC) is a simple method for the quantification of phase transition in various systems. However, no methods for the quantification of crystallization from aqueous systems based on DSC have been published until now. In the present study DSC was found to be suitable for the quantification of crystallization using supersaturated aqueous solutions of erythritol and erythritol containing gelatine gels for the first time. The developed method was validated by comparing the crystallization values determined by gravimetric measurement of erythritol crystals and the values obtained by DSC. No significant differences (p < 0.05) have been obtained between the results of the two methods if an appropriate design of measurements was applied. Additionally, the method was adapted to gelatine gels to elucidate the transferability to model food systems. Hence, the method is suitable for quantification of the amount of erythritol crystals present in aqueous solutions and gels, respectively

  7. Physical Property Modeling of Concentrated Cesium Eluate Solutions, Part I - Derivation of Models

    Energy Technology Data Exchange (ETDEWEB)

    Choi, A.S.; Pierce, R. A.; Edwards, T. B.; Calloway, T. B.

    2005-09-15

    Major analytes projected to be present in the Hanford Waste Treatment Plant cesium ion-exchange eluate solutions were identified from the available analytical data collected during radioactive bench-scale runs, and a test matrix of cesium eluate solutions was designed within the bounding concentrations of those analytes. A computer model simulating the semi-batch evaporation of cesium eluate solutions was run in conjunction with a multi-electrolyte aqueous system database to calculate the physical properties of each test matrix solution concentrated to the target endpoints of 80% and 100% saturation. The calculated physical properties were analyzed statistically and fitted into mathematical expressions for the bulk solubility, density, viscosity, heat capacity and volume reduction factor as a function of temperature and concentration of each major analyte in the eluate feed. The R{sup 2} of the resulting physical property models ranged from 0.89 to 0.99.

  8. The radiolytic reduction of mercuric chloride in aqueous sugar solutions

    International Nuclear Information System (INIS)

    Johnston, F.J.

    1991-01-01

    The reduction of HgCl 2 has been measured in Co-60 γ-irradiated aqueous glucose, fructose and sucrose solutions. G-values for reduction, G(R), are substantially greater than 6 molecules per 100 eV in all systems from 1% by weight sugar to greater than 50%. Chain reduction occurs in glucose and fructose solutions with maximum G(R) values of 18-20 molecules per 100 eV occurring at 24% (1.0 M) sugar. The results are consistent with a mechanism in which HgCl radicals react with the organic solute to produce chain propagating free radicals. A dose rate independence of the chain length, after a brief ''induction'' period, is explained in terms of a chain termination by the incorporation of HgCl in growing Hg 2 Cl 2 particles. Reduction of Ag(I) and Cu(II) in aqueous sucrose and fructose systems took place with G(R) < 6 indicating the absence of reaction chains in these cases. (author)

  9. Corrosion behavior of a superduplex stainless steel in chloride aqueous solution

    Science.gov (United States)

    Dabalà, Manuele; Calliari, Irene; Variola, Alessandra

    2004-04-01

    Super duplex stainless steels (SDSS) have been widely used as structural materials for chemical plants (especially in those engaged in phosphoric acid production), in the hydrometallurgy industries, and as materials for offshore applications due to their excellent corrosion resistance in chloride environments, compared with other commercial types of ferritic stainless steels. These alloys also possess superior weldability and better mechanical properties than austenitic stainless steels. However, due to their two-phase structure, the nature of which is very dependent on their composition and thermal history, the behavior of SDSS regarding localized corrosion appears difficult to predict, especially in chloride environments. To improve their final properties, the effect of the partition of the alloying elements between the two phases, and the composition and microstructure of each phase are the key to understanding the localized corrosion phenomena of SDSS. This paper concerns the effects of the SDSS microstructure and heat treatment on the SDSS corrosion resistance in aqueous solutions, containing different amounts of NaCl at room temperature.

  10. Selective separation of furfural and hydroxymethylfurfural from an aqueous solution using a supported hydrophobic deep eutectic solvent liquid membrane.

    Science.gov (United States)

    Dietz, Carin H J T; Kroon, Maaike C; Di Stefano, Michela; van Sint Annaland, Martin; Gallucci, Fausto

    2017-12-14

    For the first time, 12 different supported deep eutectic solvent (DES) liquid membranes were prepared and characterized. These membranes consist of a polymeric support impregnated with a hydrophobic DES. First, the different membranes were characterized and their stability in water and air was determined. Subsequently, the supported DES liquid membranes were applied for the recovery of furfural (FF) and hydroxymethylfurfural (HMF) from aqueous solutions. The effects of substrate properties (e.g. pore size), DES properties (e.g. viscosity) and concentrations of FF and HMF in the feed phase on the observed diffusivities and permeabilities were assessed. It was found that the addition of DES enhances the transport of FF and HMF through the polymeric membrane support. In particular, the use of the DES consisting of thymol + lidocaine (in the molar ratio 2 : 1) impregnated in a polyethylene support resulted in enhanced transport for both FF and HMF, and is most interesting for (in situ) isolation of FF and HMF from aqueous solutions, e.g. in biorefinery processes.

  11. The vapour pressure of water as a function of solute concentration above aqueous solutions of fructose, sucrose, raffinose, erythritol, xylitol, and sorbitol

    DEFF Research Database (Denmark)

    Cooke, S.A.; Jonsdottir, Svava Osk; Westh, Peter

    2002-01-01

    The vapour pressure of water above an aqueous solution of sucrose at T = 298.06 K has been measured for 9 sucrose mole fractions up to 0.12. Vapour pressure measurements have also been made on aqueous solutions of meso-erythritol, xylitol, sorbitol, fructose, and raffinose at T = 317.99 K...

  12. Pinning of phase separation of aqueous solution of hydroxypropylmethylcellulose by gelation

    Science.gov (United States)

    Kita, Rio; Kaku, Takeshi; Kubota, Kenji; Dobashi, Toshiaki

    1999-08-01

    Opalescence of the aqueous solution of hydroxypropylmethylcellulose (HPMC) induced by heating has been studied in terms of the phase diagram and the phase separation dynamics. The cloud point curve and the sol-to-gel transition curve intersected with each other at about 55 °C. Just above the cloud-point curve at which the spinodal curve has its minimum, a ring-like scattering pattern appeared corresponding to the spinodal decomposition. Temporal growth of the scattering function in the course of phase separation was studied by a time-resolved light scattering technique. The gelation pinned the phase separation (spinodal decomposition) of the aqueous HPMC solution.

  13. Biosorption of nickel (II) ions from aqueous solutions by tapioca peel ...

    African Journals Online (AJOL)

    Tapioca peel, waste from native tapioca starch industry in Thailand, was used for the biosorption of nickel from aqueous solution. The experimental parameter focuses on the influence of contact time, solution pH, initial concentration and temperature using batch experiments. The results indicated that the biosorption ...

  14. Removal of fluoride ions from aqueous solution by waste mud

    International Nuclear Information System (INIS)

    Kemer, Baris; Ozdes, Duygu; Gundogdu, Ali; Bulut, Volkan N.; Duran, Celal; Soylak, Mustafa

    2009-01-01

    The present study was carried out to assess the ability of original waste mud (o-WM) and different types of activated waste mud which are acid-activated (a-WM) and precipitated waste mud (p-WM), in order to remove excess of fluoride from aqueous solution by using batch technique. The p-WM exhibited greater performance than the others. Adsorption studies were conducted as a function of pH, contact time, initial fluoride concentration, adsorbent concentration, temperature, etc. Studies were also performed to understand the effect of some co-existing ions present in aqueous solutions. Adsorption process was found to be almost independent of pH for all types of waste mud. Among the kinetic models tested for p-WM, pseudo-second-order model fitted the kinetic data well with a perfect correlation coefficient value of 1.00. It was found that the adequate time for the adsorption equilibrium of fluoride was only 1 h. Thermodynamic parameters including the Gibbs free energy (ΔG o ), enthalpy (ΔH o ), and entropy (ΔS o ) revealed that adsorption of fluoride ions on the p-WM was feasible, spontaneous and endothermic in the temperature range of 0-40 deg. C. Experimental data showed a good fit with the Langmuir and Freundlich adsorption isotherm models. Results of this study demonstrated the effectiveness and feasibility of WM for removal of fluoride ions from aqueous solution.

  15. Spectral characteristics and colloidal properties of chlorophyll a{prime} in aqueous methanol

    Energy Technology Data Exchange (ETDEWEB)

    Oba, Toru [Ritsumeikan Univ., Kusatsu (Japan); Mimuro, Mamoru [National Inst. for Basic Biology, Okazaki (Japan); Wang, Z.Y.; Nozawa, Tsunenori [Tohoku Univ., Sendai (Japan); Yoshida, Shoichiro; Watanabe, Tadashi [Univ. of Tokyo (Japan)

    1997-04-17

    The `phase behavior` of chlorophyll a` (Chl a`, C13{sup 2}-epimer of Chl a) dissolved in aqueous methanol was examined in terms of the composition of the solvent. The study aimed at elucidating the property of Chl a`, the exotic pigment found in a photosynthetic reaction center complex, as well as at clarifying the nature of the Chl aggregation in aqueous media. Visible absorption, circular dichroism (CD), fluorescence and resonance Raman spectroscopies, dynamic light-scattering measurements, and electron microscopy were utilized. Chl a` formed either of two types of colloids depending on the solvent composition. The one formed over a wide methanol volume percentage (ca. 73-30%) commonly possessed a single microscopic structural unit that yielded the double-peaked absorption (ca. 690 and 715 nm) accompanied by a symmetric dispersed-type CD spectrum. Increasing methanol concentration within this solvent composition range enhanced the size of the colloid and finally caused critical opalescence, which was reminiscent of the critical behavior of the aqueous solution of nonionic surfactants. These findings indicate that the microscopic structure of the Chl a` aggregate was independent of the size and shape of the colloid. The difference between the aggregation behaviors of Chl a and a` suggests a narrower choice of possible molecular arrangements in the Chl a` aggregate as an inherent property of the pigment. 37 refs., 11 figs.

  16. Phytodegradation potential of bisphenolA from aqueous solution by Azolla Filiculoides.

    Science.gov (United States)

    Zazouli, Mohammad Ali; Mahdavi, Yousef; Bazrafshan, Edris; Balarak, Davoud

    2014-01-01

    Many organic hazardous pollutants such as bisphenolA (BPA) which are toxic and not easily biodegradable can concerns for environmental pollution worldwide. The objective of this study was to examine whether Azolla Filiculoides is able to remove BPA from aqueous solutions. In this study, the Azolla with different biomass (0.3, 0.6, 0.9, 1.2 g) has been cultured in solution that was contained 5, 10, 25 and 50 ppm BPA. Samples were collected every 2 days from all of containers. The analytical determination of BPA was performed by using of DR4000 uv-visible at λmax = 276 nm. The results indicated that Azolla has high ability to remove BPA from aqueous solutions. The BPA removal was 60-90%. The removal efficiency is increasing with decreasing of BPA concentration and increasing of biomass amount and vice versa. The removal efficiency was more than 90% when BPA concentration was 5 ppm and amount of biomass was 0.9gr. It is concluded that Azolla able remove BPA by Phytodegradation from the aqueous solutions. Since conventional methods of BPA removal need to high cost and energy, phytoremediation by Azolla as a natural treatment system can decrease those issues and it can be a useful and beneficial method to removal of BPA.

  17. Aqueous solutions of acidic ionic liquids for enhanced stability of polyoxometalate-carbon supercapacitor electrodes

    Science.gov (United States)

    Hu, Chenchen; Zhao, Enbo; Nitta, Naoki; Magasinski, Alexandre; Berdichevsky, Gene; Yushin, Gleb

    2016-09-01

    Nanocomposites based on polyoxometalates (POMs) nanoconfined in microporous carbons have been synthesized and used as electrodes for supercapacitors. The addition of the pseudocapacitance from highly reversible redox reaction of POMs to the electric double-layer capacitance of carbon lead to an increase in specific capacitance of ∼90% at 1 mV s-1. However, high solubility of POM in traditional aqueous electrolytes leads to rapid capacity fading. Here we demonstrate that the use of aqueous solutions of protic ionic liquids (P-IL) as electrolyte instead of aqueous sulfuric acid solutions offers an opportunity to significantly improve POM cycling stability. Virtually no degradation in capacitance was observed in POM-based positive electrode after 10,000 cycles in an asymmetric capacitor with P-IL aqueous electrolyte. As such, POM-based carbon composites may now present a viable solution for enhancing energy density of electrical double layer capacitors (EDLC) based on pure carbon electrodes.

  18. Removal of phosphate and nitrate from aqueous solution using ...

    African Journals Online (AJOL)

    The aim of the present study was the removal of phosphate and nitrate by sodium alginate seagrass (Cymodocea rotundata) beads from aqueous solutions. The adsorption characteristics of phosphate and nitrate on the seagrass beads were optimized under different operational parameters like adsorbent dosage, initial ...

  19. Thermodynamics of dilute aqueous solutions of imidazolium based ionic liquids

    International Nuclear Information System (INIS)

    Singh, Tejwant; Kumar, Arvind

    2011-01-01

    Research highlights: → The thermodynamic behaviour of aqueous imidazolium ILs has been investigated. → Volumetric and ultrasonic results indicated the hydrophobic hydration of ILs. → Viscometric studies revealed studied ionic liquids as water-structure makers. → Hydration number increased with increase in alkyl chain length of the cation. - Abstract: Experimental measurements of density ρ, speed of sound u, and viscosity η of aqueous solutions of various 1-alkyl-3-methylimidazolium based ionic liquid (IL) solutions have been performed in dilute concentration regime at 298.15 K to get insight into hydration behaviour of ILs. The investigated ILs are based on 1-alkyl-3-methylimidazolium cation, [C n mim] having [BF 4 ] - , [Cl] - , [C 1 OSO 3 ] - , and [C 8 OSO 3 ] - as anions where n = 4 or 8. Several thermodynamic parameters like apparent molar volume φ V , isentropic compressibility β s , and viscosity B-coefficients have been derived from experimental data. Limiting value of apparent molar volume has been discussed in terms of intrinsic molar volume (V int ) molar electrostriction volume (V elec ), molar disordered (V dis ), and cage volume (V cage ). Viscosity B-coefficients have been used to quantify the kosmotropic or chaotropic nature of ILs. Hydration number of ILs obtained using elctrostriction volume, isentropic compressibility, viscosity, and differential scanning calorimetry have been found to be comparative within the experimental error. The hydrophobic hydration has found to play an important role in hydration of ILs as compared to hydration due to hydrogen bonding and electrostriction. Limiting molar properties, hydration numbers, and B-coefficients have been discussed in terms of alkyl chain length of cation or nature of anion.

  20. Acidities of Water and Methanol in Aqueous Solution and DMSO

    Science.gov (United States)

    Gao, Daqing

    2009-01-01

    The relative acidities of water and methanol have been a nagging issue. In gas phase, methanol is more acidic than water by 36.0 kJ/mol; however, in aqueous solution, the acidities of methanol and water are almost identical. The acidity of an acid in solution is determined by both the intrinsic gas-phase ionization Gibbs energy and the solvent…

  1. Enthalpies of the dissolution and dilution of aqueous solutions of rubidium and cesium diclofenac at 293.15-318.15 K

    Science.gov (United States)

    Manin, N. G.; Perlovich, G. L.; Fini, A.

    2014-03-01

    Enthalpies of the dissolution and dilution of aqueous solutions of rubidium and cesium diclofenac (RbDC and CsDC) are measured at 293.15, 298.15, 308.15, and 318.15 K at concentrations of water of less than 0.1 mol/kg. The heat capacity of RbDC and CsDC crystal salts is determined. Changes in the thermodynamic properties of both a solution and its components vs. concentration and temperature is considered. An increase in the endothermicity of the dissolution of RbDC and CsDC with a rise in temperature is noted. It is shown that the dissolution of both RbDC and CsDC electrolytes in water is determined by the contribution from entropy. It is shown that in aqueous solutions of RbDC and CsDC, the degree of binding of water molecules is higher than in pure water at temperatures below 303.15 K.

  2. Tuning the optical properties of carbon nanotube solutions using amphiphilic self-assembly

    Science.gov (United States)

    Arnold, Michael S.; Stupp, Samuel I.; Hersam, Mark C.

    2003-07-01

    Recently it has been shown that aqueous solutions of sodium dodecyl sulfate (SDS) encapsulated and polymer wrapped single-walled carbon nanotubes (SWNTs) fluoresce in the near infrared (NIR) in the regime of the E11 van Hove transitions for semiconducting SWNTs. For bundled SWNTs, fluorescence is observed to be quenched along with a shift and broadening of the absorbance spectrum. Here, we study two other commercially available surfactants, BRIJ-97 and Triton-X-100, by analysis of carbon nanotube fluorescence and absorptivity in the NIR. It is found that changing the surfactant alters the corresponding optical properties of the solubilized carbon nanotubes. The NIR absorbance spectra of BRIJ-97 and Triton-X-100 carbon nanotube solutions are also compared with the absorbance spectrum of NaCl destabilized SDS-SWNT solutions. By controlling the amount of NaCl added to an aqueous solution of SDS-SWNTs, the optical absorbance spectrum can be made to match that of BRIJ-97 and Triton-X-100 solutions. Lastly, a correlation is drawn between the amount of shift in the absorbance spectrum and the fluorescence intensity, independent of surfactant used. This shift and decrease in fluorescence intensity may be due to carbon nanotube bundling.

  3. Adsorption of Pb(II) ions from aqueous solution using lignin from ...

    African Journals Online (AJOL)

    The adsorption of lead(II) ions from aqueous solution onto alkali lignin extracted from Hagenia abyssinica was investigated by electrochemical methods. The effect of solution pH, lignin dosage and contact time were investigated at room temperature in a batch system. Adsorption equilibrium was approached within 80 min.

  4. KDP Aqueous Solution-in-Oil Microemulsion for Ultra-Precision Chemical-Mechanical Polishing of KDP Crystal

    Directory of Open Access Journals (Sweden)

    Hui Dong

    2017-03-01

    Full Text Available A novel functional KH2PO4 (KDP aqueous solution-in-oil (KDP aq/O microemulsion system for KDP crystal ultra-precision chemical-mechanical polishing (CMP was prepared. The system, which consisted of decanol, Triton X-100, and KH2PO4 aqueous solution, was available at room temperature. The functional KDP aq/O microemulsion system was systematically studied and applied as polishing solution to KDP CMP technology. In this study, a controlled deliquescent mechanism was proposed for KDP polishing with the KDP aq/O microemulsion. KDP aqueous solution, the chemical etchant in the polishing process, was caged into the micelles in the microemulsion, leading to a limitation of the reaction between the KDP crystal and KDP aqueous solution only if the microemulsion was deformed under the effect of the external force. Based on the interface reaction dynamics, KDP aqueous solutions with different concentrations (cKDP were applied to replace water in the traditional water-in-oil (W/O microemulsion. The practicability of the controlled deliquescent mechanism was proved by the decreasing material removal rate (MRR with the increasing of the cKDP. As a result, the corrosion pits on the KDP surface were avoided to some degree. Moreover, the roughnesses of KDP with KDP aq/O microemulsion (cKDP was changed from 10 mM to 100 mM as polishing solutions were smaller than that with the W/O microemulsion. The smallest surface root-mean-square roughness of 1.5 nm was obtained at a 30 mmol/L KDP aq solution, because of the most appropriate deliquescent rate and MRR.

  5. Fast heavy-ion radiation damage of glycine in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Nomura, Shinji [Department of Nuclear Engineering, Kyoto University, Kyoto 615-8530 (Japan); Tsuchida, Hidetsugu, E-mail: tsuchida@nucleng.kyoto-u.ac.jp [Department of Nuclear Engineering, Kyoto University, Kyoto 615-8530 (Japan); Quantum Science and Engineering Center, Kyoto University, Uji 611-0011 (Japan); Furuya, Ryosuke [Department of Nuclear Engineering, Kyoto University, Kyoto 615-8530 (Japan); Majima, Takuya; Itoh, Akio [Department of Nuclear Engineering, Kyoto University, Kyoto 615-8530 (Japan); Quantum Science and Engineering Center, Kyoto University, Uji 611-0011 (Japan)

    2016-12-15

    Fast heavy-ion radiolysis of biomolecules in aqueous solution is investigated for an atomistic understanding of radiation damage to normal cells during heavy-particle beam therapy. The smallest amino acid glycine was used as a model biomaterial. Microjets of aqueous glycine solutions under vacuum were irradiated with 4.0-MeV carbon ions corresponding to energies in the Bragg peak region. To understand the effects of the water environment on molecular damage, the yield of glycine dissociation was measured by secondary ion mass spectroscopy. The yield was significantly reduced relative to gas-phase glycine targets. This implies that the numerous water molecules surrounding a single glycine molecule act as a buffer that suppresses dissociation. This is an environmental effect similar to that observed for other biomolecular cluster targets.

  6. Electronic structure tautomerism, and mechanism of H-D exchange in imidazole aqueous solutions

    International Nuclear Information System (INIS)

    Borisov, Yu.A.; Vorob'eva, N.P.; Abronin, I.A.; Kolomiets, A.F.

    1988-01-01

    The imidazole electronic structure in a gaseous phase is studied taking into account the influence of solvation effects in aqueous solutions. Possible mechanisms of tautomeric transformations and H-D exchange reactions with water molecules are discussed. Using the quantum chemistry methods, it is shown that the intramolecular mechanism of imidazole isomerization in the gaseous phase and the aqueous solution is unprofitable, and the intermolecular mechanism can proceed through the stage of protonated and carbene form formation

  7. Adsorption of ammonium dinitramide (ADN) from aqueous solutions. 1. Adsorption on powdered activated charcoal.

    Science.gov (United States)

    Santhosh, G; Venkatachalam, S; Ninan, K N; Sadhana, R; Alwan, S; Abarna, V; Joseph, M A

    2003-03-17

    Investigations on the adsorption of ammonium dinitramide (NH(4)N(NO(2))(2)) (ADN) from aqueous solutions on powdered activated charcoal (PAC) were carried out in order to find out an effective and easier method of separating ADN from aqueous solutions. The effectiveness of PAC in the selective adsorption of ADN from aqueous solutions of ADN (ADN-F) and ADN in presence of sulfate (SO(4)(2-)) and nitrate (NO(3)(-)) ions (ADN-PS) was examined and compared using batch and column methods. The adsorption process follows both Langmuir and Freundlich adsorption isotherms and the isotherm parameters for the models were determined. The observed data favor the formation of monolayer adsorption. The adsorption capacities were found to be 63.3, 119, 105.3 and 82 mg of ADN per g of PAC for ADN-F (batch), ADN-PS (batch), ADN-F (column) and ADN-PS (column), respectively. Break-through curves for ADN-F and ADN-PS were obtained for the optimization of separation of ADN from aqueous solutions. Elution curves were generated for the desorption of ADN from PAC using hot water as eluent. Copyright 2003 Elsevier Science B.V.

  8. Biosorptive removal of cobalt (II) ions from aqueous solution by ...

    African Journals Online (AJOL)

    hope&shola

    2010-11-29

    Nov 29, 2010 ... chemical reaction, decay, adsorption and biodegradation. The presence of ... sted coffee (Dakiky et al., 2002), waste tea (Ahluwalia and Goyal, 2005) ..... green removal from aqueous solution by citric acid modified rice straw.

  9. Adsorption of Chromium from Aqueous Solution Using Polyaniline

    Directory of Open Access Journals (Sweden)

    Majid Riahi Samani

    2011-10-01

    Full Text Available New group of polymers have been synthesized that are conductive of electricity so they are called conducting polymers. One of the most conducting polymers is "polyaniline". In the present study, polyaniline was synthesized by oxidizing aniline monomer under strongly acidic conditions using potassium iodate as an initiator of oxidative polymerization. Synthesized polyaniline as a powder used as an adsorbent to remove chromium from aqueous solution. Experiments were conducted in batch mode with variables such as amount of polyaniline, chromium solution pH and adsorbtion isotherms. Due to presence of Cr (III in solution after using polyaniline, removal mechanism is the combination of surface adsorption and reduction. It seems that polyaniline reduces the Cr(VI to Cr(III and adsorbs the Cr(III and a part of remaining  Cr(VI. It is well known that nitrogen atom in compounds of amine derivative makes co-ordinate bond with positive charge of metals due to the presence of electron in sp3 orbital of nitrogen. The majority of total chromium removal  occurred at 30minute for polyaniline  and the optimum  time for  hexavalent chromium  removal was about 5 min. Polyaniline has the maximum total cheomiume removal at pH, 3-9. The maximum hexavalent chromium removal occurred at acidic pH for polyanilines. The equilibrium adsorption data for polyaniline fitted both Freundlich’s and Langmuir’s isotherms. This research shows that polyaniline can be used as an adsorbent  for removal chromium from aqueous solution.

  10. Synthesis of 5'-CMP and 5'-dCMP in aqueous solution induced by low energy ions implantation

    International Nuclear Information System (INIS)

    Shi Huaibin; Shao Chunlin; Wang Xiangqin; Yu Zengliang

    2001-01-01

    Low energy N + ions produced by N 2 are accelerated and then introduced into aqueous solution to induce chemical reactions. This process avoids the need of a vacuum chamber and makes it possible to investigate the actions of low energy ions in aqueous solution. In order to explore prebiotic synthesis of nucleotide via reaction between low energy ions and aqueous solution under the primitive earth conditions, low energy N + is implanted into aqueous solution containing cytosine, D-ribose, D-2-deoxyribose and NH 4 H 2 PO 4 . It is confirmed that 5'-CMP and 5'-dCMP are produced by HPLC and 1 H-NMR analyses. The relation between yields of 5'-CMP and 5'-dCMP and irradiation time has been obtained

  11. A green process for recovery of 1-propanol/2-propanol from their aqueous solutions: Experimental and MD simulation studies

    International Nuclear Information System (INIS)

    Gupta, Bhupender S.; Taha, Mohamed; Lee, Ming-Jer

    2017-01-01

    Highlights: • A green conceptual design for separating propanols from their aqueous solutions is proposed. • TRIS is biocompatible and non-volatile and can be used as an auxiliary agent for the separation. • Isobaric VLE data for 1-propanol/2-propanol + water + TRIS were measured at 101.3 kPa. • The azeotropic compositions are significantly shifted in the presence of TRIS. • Intermolecular interactions were studied with fluorescence, COSMO-RS, and MD simulation. - Abstract: In the present study, we have found that a common and relatively inexpensive biological buffer tris(hydroxymethyl)aminomethane (TRIS) is potentially applicable to shift the azeotrope compositions of aqueous solutions of 1-propanol and 2-propanol. By taking the advantage of our findings, we are proposing a green process for the recovery of these organics from their respective aqueous solutions. In order to confirm the effect of TRIS buffer on vapor–liquid equilibrium behavior of the aqueous propanol systems, we measured the isobaric vapor–liquid equilibrium (VLE) data at 101.3 kPa for the 1-proponol + water + TRIS and 2-propanol + water + TRIS systems over the azeotropic range with various concentrations of TRIS (0.02, 0.04, 0.08, and 0.12 in mole fraction). The binary interaction parameters were obtained for TRIS with water, TRIS with 1-propanol, and TRIS with 2-propanol by correlating the new VLE data with the NRTL model. The isobaric VLE properties for the investigated propanol + water mixtures in the presence of various concentrations of TRIS were also predicted with the conductor-like screening model COSMO-RS. Based on the predicted excess molar enthalpies (H E m ) from the COSMO-RS, the interactions between all constituent pairs of molecules were estimated. To explore the mechanism of TRIS-based separation of 1-propanol/2-propanol from their aqueous solutions, the interactions between different pairs of molecules were also investigated by using fluorescence analysis and

  12. Study of Bovine Serum Albumin Solubility in Aqueous Solutions by Intrinsic Viscosity Measurements

    Directory of Open Access Journals (Sweden)

    Martin Alberto Masuelli

    2013-01-01

    Full Text Available The behavior of bovine serum albumin (BSA in water is scarcely studied, and the thermodynamic properties arising from the experimental measurements have not been reported. Intrinsic viscosity measurements are very useful in assessing the interaction between the solute and solvent. This work discussed in a simple determination of the enthalpy of BSA in aqueous solution when the concentration ranges from 0.2 to 36.71% wt. and the temperature from 35 to 40°C. The relationship between the concentration and intrinsic viscosity is determined according to the method of Huggins. The temperature increase reduces the ratio between inherent viscosity and concentration (ηi/c. This is reflected in the Van't Hoff curve. Furthermore, this work proposes hydrodynamic cohesion value as an indicator of the degree of affinity of protein with water and thermodynamic implications in conformational changes.

  13. Electrocoagulation-Adsorption to Remove Anionic and Cationic Dyes from Aqueous Solution by PV-Energy

    OpenAIRE

    Castañeda-Díaz, J.; Pavón-Silva, T.; Gutiérrez-Segura, E.; Colín-Cruz, A.

    2017-01-01

    The cationic dye malachite green (MG) and the anionic dye Remazol yellow (RY) were removed from aqueous solutions using electrocoagulation-adsorption processes. Batch and continuous electrocoagulation procedures were performed and compared. Carbonaceous materials obtained from industrial sewage sludge and commercial activated carbons were used to adsorb dyes from aqueous solutions in column systems with a 96–98% removal efficiency. The continuous electrocoagulation-adsorption system was more ...

  14. The coacervation of aqueous solutions of tetraalkylammonium halides

    International Nuclear Information System (INIS)

    Mugnier de Trobriand, Anne.

    1979-09-01

    The coacervation of aqueous solutions of tatraalkylammonium halides in the presence of not of inorganic halides and acids has been studied, considering thermodynamic and spectroscopic aspects. The importance of dispersion forces as well as forces resulting from hydrophobic hydration has been assessed. The analogy between these systems and anionic ion exchange resins has been shown especially for Uranium VI extraction [fr

  15. Structure and dynamics of aqueous solution of uranyl ions

    International Nuclear Information System (INIS)

    Chopra, Manish; Choudhury, Niharendu

    2014-01-01

    The present work describes a molecular dynamics simulation study of structure and dynamics of aqueous solution of uranyl ions in water. Structural properties of the system in terms of radial distribution functions and dynamical characteristics as obtained through velocity autocorrelation function and mean square displacements have been analyzed. The results for radial distribution functions show the oxygen of water to form the first solvation shell at 2.4 Å around the uranium atom, whereas the hydrogen atoms of water are distributed around the uranium atom with the major peak at around 3.0 Å. Analyses of transport behaviors of ions and water through MSD indicates that the diffusion of the uranyl ion is much less as compared to that of the water molecules. It is also observed that the dynamical behavior of water molecules gets modified due to the presence of uranyl ion. The effect of increase in concentration of uranyl ions on the structure and dynamics of water molecules is also studied

  16. Mutual diffusion of sodium hyaluranate in aqueous solutions

    International Nuclear Information System (INIS)

    Veríssimo, Luís M.P.; Valada, Teresa I.C.; Sobral, Abilio J.F.N.; Azevedo, Eduarda E.F.G.; Azevedo, Maria L.G.; Ribeiro, Ana C.F.

    2014-01-01

    Highlights: • Binary diffusion coefficients for the systems containing sodium hyaluronate. • Influence of the aggregation on diffusion of the sodium hyaluronate in the aqueous media. • Estimation of the thermodynamic and mobility factors from mutual diffusion. -- Abstract: The Taylor dispersion technique has been used for measuring mutual diffusion coefficients of sodium hyaluronate in aqueous solutions at T = 298.15 K, and concentrations ranging from (0.00 to 0.50) g · dm −3 . The results are interpreted on the basis of Nernst, and Onsager and Fuoss theoretical equations. From the diffusion coefficient at infinitesimal concentration, the limiting ionic conductivity and the tracer diffusion coefficient of hyaluronate ion were estimated. These studies have been complemented by molecular mechanics calculations

  17. Characterization of aqueous solution of cresol red as food irradiation dosimeter

    International Nuclear Information System (INIS)

    Khan, H.M.; Tabassum, S.; Wahid, M.S.

    2009-01-01

    Dilute aqueous solution of cresol red has been evaluated spectrophotometrically as possible gamma rays dosimeter. A 0.10 mM solution of cresol red was irradiated by gamma rays using a cobalt-60 radiation source. The absorbance spectra of the unirradiated and irradiated solutions were recorded using double beam scanning spectrophotometer. The absorbance of the solution before and after irradiation was measured at 434 nm (λ max ) as well as at other wavelengths (415, 448 and 470 nm). Various parameters, such as Absorbance (A), ΔA, %A, -log A and log A o /A i were plotted against radiation dose, in order to check the response of cresol red solution and its possible use as chemical dosimeter. The response plots of A, ΔA, and %A versus absorbed dose showed that the solution can be used as a radiation dosimeter in a dose range up to 0.82 kGy. Using response plots of -log A and log A o /A i , the useful dose range can be extended up to 1.65 kGy; which are useful dose ranges for food irradiation applications. Stability studies of cresol red solution at different light and temperature conditions for pre- and post-irradiated storage of the dosimetric solutions suggested that aqueous solution of cresol red is highly stable in dark, under fluorescence light and at room temperature up to 150 days (author)

  18. Cast iron deterioration with time in various aqueous salt solutions

    Indian Academy of Sciences (India)

    Unknown

    various aqueous salt solutions have been carried out using total immersion test ... circuit potential, Icorr, Tafel slopes, corrosion rate, have been calculated by standard methods. ..... Rao B V S 1980 in Maintenance for reliability (Bombay: Media.

  19. On reactions of polymerization of p-element hydroxides in aqueous solutions

    International Nuclear Information System (INIS)

    Tikavyj, V.F.; Lesnikovich, A.I.

    1978-01-01

    The tendency of p-element hydroxides towards polymerization in aqueous solutions has been considered with respect to their location in the Periodic Table. Stable hydroxides of d-elements are practically all polymerized; among s-elements only berillium and magnesium hydroxides polymerize as the least dissociated ones. Hydroxides of the elements located to the right of the 4 Group and above the 5-th Period do not polymerize in aqueous solutions. The structure and tendency towards polymerization of In, Te, and I compounds have been studied. The tendency to polymerization of all hydroxides of p-elements located below the 4-th Period is explained from the standpoint of electron structure and the simplest thermodynamic analysis (entropy, enthalpy)

  20. Biosorption of strontium ions from aqueous solution using Ca-alginate biopolymer beads

    International Nuclear Information System (INIS)

    Goek, C.; Aytas, S.; Gerstmann, U.

    2009-01-01

    Biosorption of strontium ions from aqueous solution onto calcium alginate biopolymer beads was investigated in a batch system. Ca-alginate biopolymer beads were prepared from Na-alginate via cross-linking with divalent calcium ions according to the egg box model. Optimum biosorption conditions were determined as a function of initial solution pH, initial Sr concentration, contact time, biomass dosage and temperature. Langmuir, Freundlich and Dubinin-Radushkevich (D-R) models were applied to describe the biosorption isotherm of Sr ions by Ca-alginate biopolymer beads. The thermodynamic parameters (ΔH, ΔS, ΔG) for Sr sorption onto biosorbent were also determined from the temperature dependence. The results indicate that this biosorbent has a good potential for removal of Sr ions from dilute aqueous solution.

  1. A novel method for determining the solubility of small molecules in aqueous media and polymer solvent systems using solution calorimetry.

    Science.gov (United States)

    Fadda, Hala M; Chen, Xin; Aburub, Aktham; Mishra, Dinesh; Pinal, Rodolfo

    2014-07-01

    To explore the application of solution calorimetry for measuring drug solubility in experimentally challenging situations while providing additional information on the physical properties of the solute material. A semi-adiabatic solution calorimeter was used to measure the heat of dissolution of prednisolone and chlorpropamide in aqueous solvents and of griseofulvin and ritonavir in viscous solutions containing polyvinylpyrrolidone and N-ethylpyrrolidone. Dissolution end point was clearly ascertained when heat generation stopped. The heat of solution was a linear function of dissolved mass for all drugs (solution of 9.8 ± 0.8, 28.8 ± 0.6, 45.7 ± 1.6 and 159.8 ± 20.1 J/g were obtained for griseofulvin, ritonavir, prednisolone and chlorpropamide, respectively. Saturation was identifiable by a plateau in the heat signal and the crossing of the two linear segments corresponds to the solubility limit. The solubilities of prednisolone and chlopropamide in water by the calorimetric method were 0.23 and 0.158 mg/mL, respectively, in agreement with the shake-flask/HPLC-UV determined values of 0.212 ± 0.013 and 0.169 ± 0.015 mg/mL, respectively. For the higher solubility and high viscosity systems of griseofulvin and ritonavir in NEP/PVP mixtures, respectively, solubility values of 65 and 594 mg/g, respectively, were obtained. Solution calorimetry offers a reliable method for measuring drug solubility in organic and aqueous solvents. The approach is complementary to the traditional shake-flask method, providing information on the solid properties of the solute. For highly viscous solutions, the calorimetric approach is advantageous.

  2. Thermodynamic study of the adsorption of chromium ions from aqueous solution on waste corn cobs material

    Directory of Open Access Journals (Sweden)

    Rafael A. Fonseca-Correa

    2014-12-01

    Full Text Available The paper shows the results of a study obtaining activated carbon from corn cobs and determining its use as an adsorbent for the removal of Cr3+ from aqueous solutions. The finely ground precursor was subjected to pyrolysis at 600 and 900 °C in a nitrogen atmosphere and chemical activation with H2O2 and HNO3. The effects of pyrolysis conditions and activation method on the physicochemical properties of the materials obtained were tested. The samples were characterised chemically and texturally. Were obtained microporous activated carbons of well-developed surface area varying from 337 to 1213 m2/g and exhibited differences acid-base character of the surface. The results obtained shows that a suitable good option of the activation procedure for corncobs permits the production of economic adsorbents with high sorption capacity for Cr3+ from aqueous solutions. A detailed study of immersion calorimetry was performed with carbons prepared from corn cobs to establish possible relationships with these materials between the enthalpies of immersion and textural and chemical parameters.

  3. Transitions in aqueous solutions of sucrose at subzero temperatures

    Czech Academy of Sciences Publication Activity Database

    Sikora, Antonín; Dupanov, V. O.; Kratochvíl, Jaroslav; Zámečník, J.

    2007-01-01

    Roč. 46, č. 1 (2007), s. 71-85 ISSN 0022-2348 R&D Projects: GA ČR(CZ) GA522/04/0384 Institutional research plan: CEZ:AV0Z40500505 Keywords : aqueous sucrose solutions * subzero temperature * glass transitions Subject RIV: BJ - Thermodynamics Impact factor: 0.809, year: 2007

  4. Absorption capacity and viscosity for CO_2 capture process using high concentrated PZ-DEAE aqueous solution

    International Nuclear Information System (INIS)

    Fu, Dong; Wang, LeMeng; Mi, ChenLu; Zhang, Pan

    2016-01-01

    Highlights: • Absorption of CO_2 in high concentrated DEAE-PZ aqueous solutions were measured. • Viscosities of CO_2-unloaded and CO_2-loaded DEAE-PZ aqueous solutions were measured. • Weiland equation was used to calculate the viscosities. • Effects of temperature, concentration and CO_2 loading on viscosity were demonstrated. - Abstract: The absorption capacity of CO_2 in piperazine (PZ) promoted 2-diethylaminoethanol (DEAE) aqueous solution was measured. The viscosities of both CO_2-unloaded and CO_2-loaded PZ-DEAE aqueous solutions were measured and then modelled. The temperatures ranged from 303.2 K to 323.2 K. The mass fraction of PZ and DEAE respectively ranged from 0 to 0.075 and 0.3 to 0.5. The temperature and concentration dependences of absorption capacity were determined. The effects of temperature, mass fraction and CO_2 loading on viscosities are demonstrated.

  5. Effect of hydrophilic additives on volumetric and viscosity properties of amino acids in aqueous solutions at T = (283.15 to 333.15) K

    International Nuclear Information System (INIS)

    Sastry, Nandhibatla V.; Valand, Pinakin H.; Macwan, Pradip M.

    2012-01-01

    Highlights: ► Densities and viscosities of amino acids in aqueous additive solutions at different temperatures. ► Side chain partial molar volumes, V ¯ 2,tr ∘ and transfer volumes ΔV tr ∘ were calculated. ► Temperature effect on volumetric functions and B-coefficients were analyzed. ► Hydrophobic side chains facilitate the solute–solute interactions and hydrophobic hydration. - Abstract: Apparent molar volumes and partial molar volumes at infinite dilution, V ¯ 2 ∘ for amino acids (glycine, L-valine, L-leucine, L-phenylalanine, and L-aspargine) aqueous solutions in sucrose (0.05 to 0.2 (w/w)), urea (0.05), 2,3-butane diol (0.05) and 2-butoxyethanol (0.05) as additives have been calculated from the experimental densities at T = (283.15 to 233.15) K. Limiting partial molar expansibilities, E 2 ∘ , side chain partial molar volumes, V ¯ 2,tr ∘ and transfer volumes (from water to aqueous additive environment), ΔV tr ∘ for both the amino acids and their side chains have also been calculated. Relative viscosities for same systems were also calculated over the same temperature range and were analyzed in terms of Jones–Dole equation to calculate B-coefficients. The analysis of volumetric functions and B-coefficients suggests that the solute–co-solute interactions are more favored at elevated temperatures and in presence of high concentration of sucrose. Otherwise the hydrophobic side chains facilitate the solute–solute interactions and also time induced hydrophobic hydration in the bulk water.

  6. Separation of cesium from aqueous solutions using alkylated tetraaryl borates

    International Nuclear Information System (INIS)

    Feldmaier, F.

    1991-01-01

    The water solubility of cesium tetraaryl borates was lowered by introducing hydrophobic aliphatic side chains into corresponding acid-resistant fluorosubstituted tetraaryl borates. This improved cesium spearability both in precipitation and in extraction from aqueous solutions. (orig.) [de

  7. (CI 42053) from an aqueous solution using Azadirachta indica leaf

    African Journals Online (AJOL)

    STORAGESEVER

    2008-11-05

    Nov 5, 2008 ... ... 42053) from an aqueous solution using Azadirachta indica leaf powder as a low- ... and biodegradable effective adsorbents. They were ob- tained from ... pesticide. The trees are also known as an air purifier. The medicinal.

  8. Cation exchange properties of zeolites in hyper alkaline aqueous media.

    Science.gov (United States)

    Van Tendeloo, Leen; de Blochouse, Benny; Dom, Dirk; Vancluysen, Jacqueline; Snellings, Ruben; Martens, Johan A; Kirschhock, Christine E A; Maes, André; Breynaert, Eric

    2015-02-03

    Construction of multibarrier concrete based waste disposal sites and management of alkaline mine drainage water requires cation exchangers combining excellent sorption properties with a high stability and predictable performance in hyper alkaline media. Though highly selective organic cation exchange resins have been developed for most pollutants, they can serve as a growth medium for bacterial proliferation, impairing their long-term stability and introducing unpredictable parameters into the evolution of the system. Zeolites represent a family of inorganic cation exchangers, which naturally occur in hyper alkaline conditions and cannot serve as an electron donor or carbon source for microbial proliferation. Despite their successful application as industrial cation exchangers under near neutral conditions, their performance in hyper alkaline, saline water remains highly undocumented. Using Cs(+) as a benchmark element, this study aims to assess the long-term cation exchange performance of zeolites in concrete derived aqueous solutions. Comparison of their exchange properties in alkaline media with data obtained in near neutral solutions demonstrated that the cation exchange selectivity remains unaffected by the increased hydroxyl concentration; the cation exchange capacity did however show an unexpected increase in hyper alkaline media.

  9. Recovery of Ionic Liquids from aqueous solution by Nanofiltration

    OpenAIRE

    Fernández Dámaso, José Francisco

    2011-01-01

    The T-SAR methodology was combined with membrane characterization methods. An application of the combined approach was demonstrated with two commercial nanofiltration membranes and it was possible to successfully predict their performance for the recovery of ionic liquids from aqueous solution. Using model solutions of Pyr16 (CF3SO2)2N, it could be evidenced the formation of a new phase of ionic liquid during the concentration process. In this case, 66% of the ionic liquid was separated and t...

  10. Inhibition of the solid state transformation of carbamazepine in aqueous solution: impact of polymeric properties.

    Science.gov (United States)

    Gift, Alan D; Hettenbaugh, Jacob A; Quandahl, Rachel A; Mapes, Madison

    2017-11-06

    The effects of polymers on the anhydrate-to-hydrate transformation of carbamazepine (CBZ) was investigated. The three types of polymers studied were polyvinylpyrrolidone (PVP), polyvinyl alcohol (PVA) and substituted celluloses which included hydroxypropyl methylcellulose (HPMC) and methylcellulose (MC). Anhydrous CBZ was added to dilute aqueous polymer solutions and Raman spectroscopy measurements were collected to monitor the kinetics of the solution-mediated transformation to CBZ dihydrate. Polymers exhibiting the greatest inhibition were able to reduce the growth phase of the solution-mediated transformation and change the habit of the hydrate crystal indicating polymer adsorption to the hydrate crystal surface as the mechanism of inhibition. The results of the various polymers showed that short chain substituted celluloses (HPMC and MC) inhibited the CBZ transformation to a much greater extent than longer chains. The same trend was observed for PVP and PVA, but to a lesser extent. These chain length effects were attributed to changes in polymer confirmation when adsorbed on the crystal surface. Additionally, decreasing the percentage of hydroxyl groups on the PVA polymer backbone reduced the ability of the polymer to inhibit the transformation and changing the degree of substitutions of methyl and hydroxypropyl groups on the cellulosic polymer backbone had no effect on the transformation.

  11. Long-term results of treatment with diquafosol ophthalmic solution for aqueous-deficient dry eye.

    Science.gov (United States)

    Koh, Shizuka; Ikeda, Chikako; Takai, Yoshihiro; Watanabe, Hitoshi; Maeda, Naoyuki; Nishida, Kohji

    2013-09-01

    To evaluate the preliminary long-term efficacy of diquafosol ophthalmic solution for aqueous-deficient dry eye. Fifteen patients with mild-to-moderate aqueous-deficient dry eye were enrolled. After a washout period, the patients were treated with 3 % diquafosol ophthalmic solution for 6 months. We assessed 12 subjective dry eye symptoms, corneal and conjunctival staining with fluorescein, tear film break-up time (BUT), lower tear meniscus height measured with anterior-segment optical coherence tomography, Schirmer's testing, and adverse reactions at baseline and 1, 3, and 6 months after the start of treatment. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining, BUT, and tear meniscus height at 1 month and maintained the effectiveness for 6 months. Conjunctival staining significantly improved 3 and 6 months after treatment. No significant adverse reactions developed. Prolonged use of diquafosol ophthalmic solution for 6 months produced significant improvement both subjectively (dry eye symptom score) and objectively (ocular staining score and tear function tests) for aqueous-deficient dry eye.

  12. Glass-to-cryogenic-liquid transitions in aqueous solutions suggested by crack healing.

    Science.gov (United States)

    Kim, Chae Un; Tate, Mark W; Gruner, Sol M

    2015-09-22

    Observation of theorized glass-to-liquid transitions between low-density amorphous (LDA) and high-density amorphous (HDA) water states had been stymied by rapid crystallization below the homogeneous water nucleation temperature (∼235 K at 0.1 MPa). We report optical and X-ray observations suggestive of glass-to-liquid transitions in these states. Crack healing, indicative of liquid, occurs when LDA ice transforms to cubic ice at 160 K, and when HDA ice transforms to the LDA state at temperatures as low as 120 K. X-ray diffraction study of the HDA to LDA transition clearly shows the characteristics of a first-order transition. Study of the glass-to-liquid transitions in nanoconfined aqueous solutions shows them to be independent of the solute concentrations, suggesting that they represent an intrinsic property of water. These findings support theories that LDA and HDA ice are thermodynamically distinct and that they are continuously connected to two different liquid states of water.

  13. Glass-to-cryogenic-liquid transitions in aqueous solutions suggested by crack healing

    Science.gov (United States)

    Kim, Chae Un; Tate, Mark W.; Gruner, Sol M.

    2015-01-01

    Observation of theorized glass-to-liquid transitions between low-density amorphous (LDA) and high-density amorphous (HDA) water states had been stymied by rapid crystallization below the homogeneous water nucleation temperature (∼235 K at 0.1 MPa). We report optical and X-ray observations suggestive of glass-to-liquid transitions in these states. Crack healing, indicative of liquid, occurs when LDA ice transforms to cubic ice at 160 K, and when HDA ice transforms to the LDA state at temperatures as low as 120 K. X-ray diffraction study of the HDA to LDA transition clearly shows the characteristics of a first-order transition. Study of the glass-to-liquid transitions in nanoconfined aqueous solutions shows them to be independent of the solute concentrations, suggesting that they represent an intrinsic property of water. These findings support theories that LDA and HDA ice are thermodynamically distinct and that they are continuously connected to two different liquid states of water. PMID:26351671

  14. Sorption Potentials of Waste Tyre for Some Heavy Metals (Pb Cd in Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Austin Kanayo ASIAGWU

    2009-07-01

    Full Text Available An investigation into the adsorption potential of activated and inactivated waste tyre powders for some heavy metals (Pb2+ and Cd2+ in their aqueous solution has been studied. The result indicated that inactivated waste tyre is a good non-conventional adsorbent for the removal of Cd from aqueous solution. A total of 93.3% of Cadmium contents was removed. The inactivated waste type proved a good adsorbent for the removal of Pb2+ 5g of 500mm activated tyre removed over 86.66% of Pb2+ from solution.

  15. ISOCHORIC HEAT CAPACITY OF 1% AQUEOUS SOLUTION OF MAGNESIUM CHLORIDE

    Directory of Open Access Journals (Sweden)

    V. I. Dvoryanchikov

    2016-01-01

    Full Text Available Aim. The aim is to conduct an experimental study of isochoric heat capacity of 1% aqueous solution of magnesium chloride along the phase boundary curve.Method. In order to determine the isochoric heat capacity at the phase boundary curve we used the adiabatic calorimeter of KH. I. Amirkhanov.Results. Results of the study of the isochoric heat capacity depending on the temperature are given in tables and figures; the findings are compared with those of other researchers. When evaluating a complex system, we ought not to evaluate its effectiveness on the basis of only one criterion, even a very important, in this case must take into account the requirements of the technical, economic, environmental and of other natures.Conclusions. When solving optimization problems of efficiency in geothermal energy it is necessary to take into account the fact of the temperature dependence of the heat and density. The temperature dependence of the density and heat capacity in the calculations significantly affect the value of the efficiency criterion to be taken into account, otherwise the calculation error can be up to 20%. The data obtained from the isochoric heat capacity of aqueous solutions of magnesium chloride is compared with the data for water and aqueous solutions of NaCl and NaOH, obtained previously, which may be represented as a model of geothermal and sea water.

  16. Removal of fluoride ions from aqueous solution by waste mud

    Energy Technology Data Exchange (ETDEWEB)

    Kemer, Baris; Ozdes, Duygu; Gundogdu, Ali; Bulut, Volkan N.; Duran, Celal [Karadeniz Technical University, Faculty of Arts and Sciences, Department of Chemistry, 61080 Trabzon (Turkey); Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr [Erciyes University, Faculty of Arts and Sciences, Department of Chemistry, 38039 Kayseri (Turkey)

    2009-09-15

    The present study was carried out to assess the ability of original waste mud (o-WM) and different types of activated waste mud which are acid-activated (a-WM) and precipitated waste mud (p-WM), in order to remove excess of fluoride from aqueous solution by using batch technique. The p-WM exhibited greater performance than the others. Adsorption studies were conducted as a function of pH, contact time, initial fluoride concentration, adsorbent concentration, temperature, etc. Studies were also performed to understand the effect of some co-existing ions present in aqueous solutions. Adsorption process was found to be almost independent of pH for all types of waste mud. Among the kinetic models tested for p-WM, pseudo-second-order model fitted the kinetic data well with a perfect correlation coefficient value of 1.00. It was found that the adequate time for the adsorption equilibrium of fluoride was only 1 h. Thermodynamic parameters including the Gibbs free energy ({Delta}G{sup o}), enthalpy ({Delta}H{sup o}), and entropy ({Delta}S{sup o}) revealed that adsorption of fluoride ions on the p-WM was feasible, spontaneous and endothermic in the temperature range of 0-40 deg. C. Experimental data showed a good fit with the Langmuir and Freundlich adsorption isotherm models. Results of this study demonstrated the effectiveness and feasibility of WM for removal of fluoride ions from aqueous solution.

  17. Preferential adsorption of uranium ions in aqueous solutions by polymers

    International Nuclear Information System (INIS)

    Sakuragi, Masako; Ichimura, Kunihiro; Fujishige, Shoei; Kato, Masao

    1981-01-01

    Amidoxime fiber and triazine fiber were prepared by chemical modification of commercially available polyacrylonitril fiber. It was found that the Amidoxime fiber is efficient to adsorb uranium ions in the artificial sea water. The efficiency of the preferential adsorption decreases by treatment the material with an acid-or an alkaline-solution. The triazine fiber adsorbs uranium ions only in aqueous solutions of such uranyl acetate, in the absence of other ions. In the artificial sea water, it adsorbs other ions instead of uranium. The preferential adsorption of uranium ions was further investigated with a series of polystyrenesulfonamides. Among the polystyrene derivatives, those having carboxyl groups, derived from imino diacetic acid (PSt-Imi), β-alanine (PSt-Ala), glycine (PSt-Gly), and sarcosine (PSt-Sar) were qualified for further discussion. However, it was found that the amount of adsorption of uranium ions by PSt-Imi decreases with increasing the volume of the artificial sea water and/or the duration of the treatment. Taking into account the facts, the preferential adsorption of uranium ions by PSt-Imi in aqueous solution was discussed in detail. (author)

  18. Removal of Cholera Toxin from Aqueous Solution by Probiotic Bacteria

    Directory of Open Access Journals (Sweden)

    Jussi A. O. Meriluoto

    2012-06-01

    Full Text Available Cholera remains a serious health problem, especially in developing countries where basic hygiene standards are not met. The symptoms of cholera are caused by cholera toxin, an enterotoxin, which is produced by the bacterium Vibrio cholerae. We have recently shown that human probiotic bacteria are capable of removing cyanobacterial toxins from aqueous solutions. In the present study we investigate the ability of the human probiotic bacteria, Lactobacillus rhamnosus strain GG (ATCC 53103 and Bifidobacterium longum 46 (DSM 14583, to remove cholera toxin from solution in vitro. Lactobacillus rhamnosus strain GG and Bifidobacterium longum 46 were able to remove 68% and 59% of cholera toxin from aqueous solutions during 18 h of incubation at 37 °C, respectively. The effect was dependent on bacterial concentration and L. rhamnosus GG was more effective at lower bacterial concentrations. No significant effect on cholera toxin concentration was observed when nonviable bacteria or bacterial supernatant was used.

  19. Enzyme stabilization by glass-derived silicates in glass-exposed aqueous solutions

    Science.gov (United States)

    Ives, J.A.; Moffett, J.R.; Arun, P.; Lam, D.; Todorov, T.I.; Brothers, A.B.; Anick, D.J.; Centeno, J.; Namboodiri, M.A.A.; Jonas, W.B.

    2010-01-01

    Objectives: To analyze the solutes leaching from glass containers into aqueous solutions, and to show that these solutes have enzyme activity stabilizing effects in very dilute solutions. Methods: Enzyme assays with acetylcholine esterase were used to analyze serially succussed and diluted (SSD) solutions prepared in glass and plastic containers. Aqueous SSD preparations starting with various solutes, or water alone, were prepared under several conditions, and tested for their solute content and their ability to affect enzyme stability in dilute solution. Results: We confirm that water acts to dissolve constituents from glass vials, and show that the solutes derived from the glass have effects on enzymes in the resultant solutions. Enzyme assays demonstrated that enzyme stability in purified and deionized water was enhanced in SSD solutions that were prepared in glass containers, but not those prepared in plastic. The increased enzyme stability could be mimicked in a dose-dependent manner by the addition of silicates to the purified, deionized water that enzymes were dissolved in. Elemental analyses of SSD water preparations made in glass vials showed that boron, silicon, and sodium were present at micromolar concentrations. Conclusions: These results show that silicates and other solutes are present at micromolar levels in all glass-exposed solutions, whether pharmaceutical or homeopathic in nature. Even though silicates are known to have biological activity at higher concentrations, the silicate concentrations we measured in homeopathic preparations were too low to account for any purported in vivo efficacy, but could potentially influence in vitro biological assays reporting homeopathic effects. ?? 2009 The Faculty of Homeopathy.

  20. Comparison Study On Sunlight Or Gamma Radiation Aging Resistance Of Poly (Vinyl Pyrrolidone) Aqueous Solution With PVP Nanogel

    International Nuclear Information System (INIS)

    Doan Binh; Pham Thu Hong; Nguyen Nguyet Dieu; Nguyen Thanh Duoc

    2011-01-01

    Comparison study on sunlight or gamma-radiation aging resistance of poly (vinyl pyrrolidone) (PVP) aqueous solution with PVP nanogel at 0.5% was carried out. Sunlight or gamma- radiation aging resistance of PVP aqueous solution and nanogel was evaluated on the basis of their intrinsic viscosity, UV-VIS absorbance, weight averaged molecular weight (M w ). The PVP aqueous solution and nanogel exposed to sunlight in the storage duration of 3 months and to gamma radiation at absorbed doses of 0, 15, 30, 50 kGy were used for this study. Furthermore, the stability of PVP nanogel and of PVP aqueous solution was also studied on the change of their intrinsic viscosity, UV-VIS absorbance, weight averaged molecular weight, particle size distribution and coil size. The experimental results were shown that the aging resistance of PVP nanogel was higher than that of PVP aqueous solution when exposed to gamma radiation or sunlight. (author)

  1. from an aqueous solution using Azadirachta indica leaf powder

    African Journals Online (AJOL)

    Azadirachta indica (neem) leaf powder was used as an adsorbent for the removal of textile dye from aqueous solution. The adsorption of dye on A. indica was found to be dependent on contact time, dye concentration and amount of adsorbent. Spectrophotometric technique was used for the measurement of concentration of ...

  2. A DFT/TDDFT study of the structural and spectroscopic properties of Al(III) complexes with 4-nitrocatechol in acidic aqueous solution

    International Nuclear Information System (INIS)

    Cornard, Jean-Paul; Lapouge, Christine; Merlin, Jean-Claude

    2007-01-01

    The complexation of 4-nitrocatechol in aqueous solution at pH 5 has been studied by molecular spectroscopy combined with quantum chemical calculations. In these physico-chemical conditions, the formation of the two complexes [4ncatAl(H 2 O) 4 ] + and [(4ncat) 2 Al(H 2 O) 2 ] - has been highlighted. The electronic absorption spectra of the 1:1 and 1:2 complexes of Al(III) with 4-nitrocatechol have been computed using the time-dependent density functional theory and the polarizable continuum model. It turns out that the 6-311+G(d,p) basis set provides a good agreement between experimental and theoretical absorption spectra. This good agreement has allowed the determination of the preferential conformation of the 1:2 complex in aqueous solution. A complete assignment of the UV-Vis absorption and Raman spectra of the complexes has been proposed

  3. Adsorption of tannic acid from aqueous solution onto surfactant-modified zeolite

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jianwei, E-mail: jwlin@shou.edu.cn [College of Marine Science, Shanghai Ocean University, No. 999 Hucheng Huan Road, Pudong District, Shanghai 201306 (China); Zhan, Yanhui; Zhu, Zhiliang [State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092 (China); Xing, Yunqing [College of Marine Science, Shanghai Ocean University, No. 999 Hucheng Huan Road, Pudong District, Shanghai 201306 (China)

    2011-10-15

    Graphical abstract: Surfactant-modified zeolites (SMZs) with various loadings of cetylpyridinium bromide (CPB) were used as adsorbents to remove tannic acid (TA) from aqueous solution. Highlights: {yields} Surfactant modified zeolites (SMZs) have a good tannic acid (TA) adsorption capacity. {yields} Adsorption capacity for SMZ with bilayer was relatively high at solution pH 3.5-7.0. {yields} Adsorption was well described by pseudo-second-order kinetic model. {yields} Adsorption fitted well with Langmuir, Redlich-Peterson and Sips isotherm models. {yields} Coexisting Cu(II) in aqueous solution resulted in markedly enhanced TA adsorption. - Abstract: Surfactant-modified zeolites (SMZs) with various loadings of cetylpyridinium bromide (CPB) were used as adsorbents to remove tannic acid (TA) from aqueous solution. The TA adsorption efficiencies for natural zeolite and various SMZs were compared. SMZ presented higher TA adsorption efficiency than natural zeolite, and SMZ with higher loading amount of CPB exhibited higher TA adsorption efficiency. The adsorption of TA onto SMZ as a function of contact time, initial adsorbate concentration, temperature, ionic strength, coexisting Cu(II) and solution pH was investigated. The adsorbents before and after adsorption were characterized by X-ray diffraction (XRD), field emission scanning electron microscope (FE-SEM), thermogravimetric analysis (TGA), and Fourier transform infrared (FT-IR) spectroscopy. The adsorption kinetics of TA onto SMZ with CPB bilayer coverage (SMZ-CBC) followed a pseudo-second-order model. The equilibrium adsorption data of TA onto SMZ-CBC were well represented by Langmuir, Redlich-Peterson and Sips isotherm models. The calculated thermodynamic parameters indicated that TA adsorption onto SMZ-CBC was spontaneous and exothermic. The TA adsorption capacity for SMZ-CBC slightly decreased with increasing ionic strength but significantly increased with increasing Cu(II) concentration. The TA adsorption

  4. Rapid synthesis of CdSe nanocrystals in aqueous solution at room ...

    Indian Academy of Sciences (India)

    Administrator

    Water-soluble thioglycolic acid-capped CdSe nanocrystals (NCs) were prepared in aqueous solu- tion at room temperature. We investigated the ... NCs dispersed in buffer solution (pH = 4⋅0). FTIR spectra were recorded on a ... the theory of acid-base equilibrium, the initial pH value of original solution determines the ...

  5. Protective effects of vitamin glycosides on γ-radiation and H2O2-induced decomposition of thymine in aqueous solutions

    International Nuclear Information System (INIS)

    Shadyro, O.; Lagutin, P.; Edimecheva, I.; Brinkevich, S.; Kagiya, Tsutomu

    2008-01-01

    Effects of ascorbic acid (AA), ascorbic acid glycoside (AAG) and α-tocopherol monoglycoside (TMG) on radiation- and H 2 O 2 -induced decomposition of thymine in aqueous solutions were investigated. Of the three compounds studied, AAG was found to possess the most marked protector properties. An explanation of this phenomenon has been given in terms of differences in molecular structures of AA and AAG, as well as properties of radical adducts formed during their interaction with OH radicals. (author)

  6. Effect of liquid oil additive on lithium-ion battery ceramic composite separator prepared with an aqueous coating solution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Woo [Division of Advanced Materials Engineering, Kongju National University, 1223–24, Cheonan-daero, Cheonan, Chungnam, 31080 (Korea, Republic of); Ryou, Myung-Hyun [Department of Chemical & Biological Engineering, Hanbat National University, 125, Dongseodaero, Yuseong-gu, Daejeon, 34158 (Korea, Republic of); Lee, Yong Min, E-mail: yongmin.lee@hanbat.ac.kr [Department of Chemical & Biological Engineering, Hanbat National University, 125, Dongseodaero, Yuseong-gu, Daejeon, 34158 (Korea, Republic of); Cho, Kuk Young, E-mail: kycho@hanyang.ac.kr [Department of Materials Science and Chemical Engineering, Hanyang University, 55, Hanyangdaehak-ro, Sangrok-gu, Ansan, Gyeonggi-do, 15588 (Korea, Republic of)

    2016-08-05

    Ceramic composite separators (CCSs) play a critical role in ensuring safety for lithium-ion batteries (LIBs), especially for mid- and large-sized devices. However, production of CCSs using organic solvents has some cost and environmental concerns. An aqueous process for fabricating CCSs is attractive because of its cost-effectiveness and environmental-friendliness because organic solvents are not used. The success of an aqueous coating system for LIBs is dependent upon minimizing moisture content, as moisture has a negatively impact on LIB performance. In this study, CCSs were fabricated using an aqueous coating solution containing Al{sub 2}O{sub 3} and an acrylic binder. Compared with polyethylene (PE) separators, CCSs coated with an aqueous coating solution showed improved thermal stability, electrolyte uptake, puncture strength, ionic conductivity, and rate capability. In addition, our new approach of introducing a small amount of an oily liquid to the aqueous coating solution reduced the water adsorption by 11.7% compared with coatings that do not contain the oily liquid additive. - Highlights: • Ceramic composite separator is fabricated using aqueous coating process. • Coated separator showed enhanced mechanical and thermal stability. • Liquid oil additive in coating solution reduce moisture reabsorption of separator. • Oil additive in aqueous coating solution does not deteriorate LIB performance.

  7. Group additivity calculations of the thermodynamic properties of unfolded proteins in aqueous solution: a critical comparison of peptide-based and HKF models.

    Science.gov (United States)

    Hakin, A W; Hedwig, G R

    2001-02-15

    A recent paper in this journal [Amend and Helgeson, Biophys. Chem. 84 (2000) 105] presented a new group additivity model to calculate various thermodynamic properties of unfolded proteins in aqueous solution. The parameters given for the revised Helgeson-Kirkham-Flowers (HKF) equations of state for all the constituent groups of unfolded proteins can be used, in principle, to calculate the partial molar heat capacity, C(o)p.2, and volume, V2(0), at infinite dilution of any polypeptide. Calculations of the values of C(o)p.2 and V2(0) for several polypeptides have been carried out to test the predictive utility of the HKF group additivity model. The results obtained are in very poor agreement with experimental data, and also with results calculated using a peptide-based group additivity model. A critical assessment of these two additivity models is presented.

  8. An Exact Method to Determine the Conductivity of Aqueous Solutions in Acid-Base Titrations

    Directory of Open Access Journals (Sweden)

    Norma Rodríguez-Laguna

    2015-01-01

    Full Text Available Several works in the literature show that it is possible to establish the analytic equations to estimate the volume V of a strong base or a strong acid (Vb and Va, resp. being added to a solution of a substance or a mix of substances during an acid-base titration, as well as the equations to estimate the first derivative of the titration plot dpH/dV, and algebraic expressions to determine the buffer β capacity with dilution βdil. This treatment allows establishing the conditions of thermodynamic equilibria for all species within a system containing a mix of species from one or from various polyacid systems. The present work shows that it is possible to determine exactly the electric conductivity of aqueous solutions for these Brønsted acid-base titrations, because the functional relation between this property and the composition of the system in equilibrium is well known; this is achieved using the equivalent conductivity λi values of each of the ions present in a given system. The model employed for the present work confirms the experimental outcomes with the H2SO4, B(OH3, CH3COOH, and H3PO4 aqueous solutions’ titration.

  9. Gamma-radiolysis of aqueous solutions of methyl orange and chrysoidine

    International Nuclear Information System (INIS)

    Khabarov, V.N.; Kozlov, L.L.; Panchenkov, G.M.

    1980-01-01

    Radiation-chemical bleaching of azo dyes of methyl orange and chrysoidine in aqueous and aqueous-alcoholic solutions under the effect of γ-radiation of 60 Co is studied. The effect of different additions and pH value of medium upon radiolysis of azo dyes is investigated. Radiation-chemical yields of the bleaching are determined. Quantitative connection between the initial yields of water radiolysis products and radiation yields of the bleaching of azo dyes is established. On the basis of the results obtained the most probable mechanism of methyl orange and chrysoidine bleaching is suggested

  10. Electrochemical reactions of uranyl(VI) complexes in aqueous solution, non-aqueous solvents, and ionic liquids

    International Nuclear Information System (INIS)

    Ikeda, Yasuhisa

    2006-01-01

    Author's recent experimental results on the chemistry of U(V) in aqueous solution, non-aqueous solvents, and ionic solvents by cyclic voltametry are described. The U(V) was produced by electrochemical reduction of uranyl U(VI) ions or complexes such as carbonates, DMF(N, N-dimethylformamide), DMSO(dimethylsulfoxide), acetylacetonato, and other organic polydental ligands. The produced U(V) complexes were studied by spectrophotometry using optical-transmission thin-layer electrode. The U(V) complexes in non-aqueous solvents were found to be rather stable, they undergo ligand-dissociation reaction but not disproportionation reaction. The structure and electronic spectra as well as IR spectra of the complexes were studied. The present method was further developed to study the behavior of U(V) complexes in ionic liquids as molten salts, e.g., alkaline metals chlorides. Thus, the present research contributes to understanding the chemistry of 5fl system. Application to such nuclear technology as spent fuel reprocessing is discussed. (S. Ohno)

  11. The partial molar heat capacity, expansion, isentropic, and isothermal compressions of thymidine in aqueous solution at T = 298.15 K

    International Nuclear Information System (INIS)

    Hedwig, Gavin R.; Jameson, Geoffrey B.; Hoiland, Harald

    2011-01-01

    Highlights: → Solution densities and sound speeds were measured for aqueous solutions of thymidine. → Partial molar volumetric properties at infinite dilution and T = 298.15 K were derived. → The partial molar isentropic and isothermal compressions are of opposite signs. → The partial molar heat capacity for thymidine at infinite dilution was determined. - Abstract: Solution densities have been determined for aqueous solutions of thymidine at T = (288.15, 298.15, 303.15, and 313.15) K. The partial molar volumes at infinite dilution, V 2 0 , obtained from the density data were used to derive the partial molar isobaric expansion at infinite dilution for thymidine at T = 298.15 K, E 2 0 {E 2 0 =(∂V 2 0 /∂T) p }. The partial molar heat capacity at infinite dilution for thymidine, C p,2 0 , at T = 298.15 K has also been determined. Sound speeds have been measured for aqueous solutions of thymidine at T = 298.15 K. The partial molar isentropic compression at infinite dilution, K S,2 0 , and the partial molar isothermal compression at infinite dilution, K T,2 0 {K T,2 0 =-(∂V 2 0 /∂P) T }, have been derived from the sound speed data. The V 2 0 , E 2 0 , C p,2 0 , and K S,2 0 results for thymidine are critically compared with those available from the literature.

  12. Removal of uranium from aqueous solution by a low cost and high-efficient adsorbent

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yun-Hai [State Key Laboratory Breeding Base of Nuclear Resources and Environment (East China Institute of Technology), Ministry of Education, Nanchang, 330013 (China); Key Laboratory of Radioactive Geology and Exploration Technology Fundamental Science for National Defense, East China Institute of Technology, Fuzhou, 344000 (China); Chemistry, Biological and Materials Sciences Department, East China Institute of Technology, Fuzhou, 344000 (China); Wang, You-Qun [Key Laboratory of Radioactive Geology and Exploration Technology Fundamental Science for National Defense, East China Institute of Technology, Fuzhou, 344000 (China); Chemistry, Biological and Materials Sciences Department, East China Institute of Technology, Fuzhou, 344000 (China); Zhang, Zhi-Bin, E-mail: zhangnjut@163.com [State Key Laboratory Breeding Base of Nuclear Resources and Environment (East China Institute of Technology), Ministry of Education, Nanchang, 330013 (China); Key Laboratory of Radioactive Geology and Exploration Technology Fundamental Science for National Defense, East China Institute of Technology, Fuzhou, 344000 (China); Chemistry, Biological and Materials Sciences Department, East China Institute of Technology, Fuzhou, 344000 (China); Cao, Xiao-Hong; Nie, Wen-Bin; Li, Qin [Key Laboratory of Radioactive Geology and Exploration Technology Fundamental Science for National Defense, East China Institute of Technology, Fuzhou, 344000 (China); Chemistry, Biological and Materials Sciences Department, East China Institute of Technology, Fuzhou, 344000 (China); Hua, Rong [State Key Laboratory Breeding Base of Nuclear Resources and Environment (East China Institute of Technology), Ministry of Education, Nanchang, 330013 (China); Key Laboratory of Radioactive Geology and Exploration Technology Fundamental Science for National Defense, East China Institute of Technology, Fuzhou, 344000 (China); Chemistry, Biological and Materials Sciences Department, East China Institute of Technology, Fuzhou, 344000 (China)

    2013-05-15

    In this study, a low-cost and high-efficient carbonaceous adsorbent (HTC-COOH) with carboxylic groups was developed for U(VI) removal from aqueous solution compared with the pristine hydrothermal carbon (HTC). The structure and chemical properties of resultant adsorbents were characterized by Scanning electron microscope (SEM), N{sub 2} adsorption–desorption, Fourier transform-infrared spectra (FT-IR) and acid–base titration. The key factors (solution pH, contact time, initial U(VI) concentrations and temperature) affected the adsorption of U(VI) on adsorbents were investigated using batch experiments. The adsorption of U(VI) on HTC and HTC-COOH was pH-dependent, and increased with temperature and initial ion concentration. The adsorption equilibrium of U(VI) on adsorbents was well defined by the Langmuir isothermal equation, and the monolayer adsorption capacity of HTC-COOH was found to be 205.8 mg/g. The kinetics of adsorption was very in accordance with the pseudo-second-order rate model. The adsorption processes of U(VI) on HTC and HTC-COOH were endothermic and spontaneous in nature according to the thermodynamics of adsorption. Furthermore, HTC-COOH could selectively adsorption of U(VI) in aqueous solution containing co-existing ions (Mg{sup 2+}, Co{sup 2+}, Ni{sup 2+}, Zn{sup 2+} and Mn{sup 2+}). From the results of the experiments, it is found that the HTC-COOH is a potential adsorbent for effective removal of U(VI) from polluted water.

  13. Removal of uranium from aqueous solution by a low cost and high-efficient adsorbent

    Science.gov (United States)

    Liu, Yun-Hai; Wang, You-Qun; Zhang, Zhi-Bin; Cao, Xiao-Hong; Nie, Wen-Bin; Li, Qin; Hua, Rong

    2013-05-01

    In this study, a low-cost and high-efficient carbonaceous adsorbent (HTC-COOH) with carboxylic groups was developed for U(VI) removal from aqueous solution compared with the pristine hydrothermal carbon (HTC). The structure and chemical properties of resultant adsorbents were characterized by Scanning electron microscope (SEM), N2 adsorption-desorption, Fourier transform-infrared spectra (FT-IR) and acid-base titration. The key factors (solution pH, contact time, initial U(VI) concentrations and temperature) affected the adsorption of U(VI) on adsorbents were investigated using batch experiments. The adsorption of U(VI) on HTC and HTC-COOH was pH-dependent, and increased with temperature and initial ion concentration. The adsorption equilibrium of U(VI) on adsorbents was well defined by the Langmuir isothermal equation, and the monolayer adsorption capacity of HTC-COOH was found to be 205.8 mg/g. The kinetics of adsorption was very in accordance with the pseudo-second-order rate model. The adsorption processes of U(VI) on HTC and HTC-COOH were endothermic and spontaneous in nature according to the thermodynamics of adsorption. Furthermore, HTC-COOH could selectively adsorption of U(VI) in aqueous solution containing co-existing ions (Mg2+, Co2+, Ni2+, Zn2+ and Mn2+). From the results of the experiments, it is found that the HTC-COOH is a potential adsorbent for effective removal of U(VI) from polluted water.

  14. WHATIF-AQ, Geochem Speciation and Saturation of Aqueous Solution

    International Nuclear Information System (INIS)

    Nielsen, Ole John; Jensen, Bror Skytte

    1988-01-01

    1 - Description of program or function: WHATIF-AQ is part of a family of programs for calculations of geochemistry in the near-field of radioactive waste with temperature gradients. The program calculates speciation and saturation indices for an aqueous solution at temperatures in the range 0 - 125 degrees C. The chemical equilibrium is determined by solving a set of nonlinear equations consisting of the equilibrium constant and mass balance constraints. 2 - Method of solution: The set of equations is solved using a generalized Newton-Raphson technique

  15. Comparative analysis of the effect of pretreating aspen wood with aqueous and aqueous-organic solutions of sulfuric and nitric acid on its reactivity during enzymatic hydrolysis

    DEFF Research Database (Denmark)

    Dotsenko, Gleb; Osipov, D. O.; Zorov, I. N.

    2016-01-01

    The effect of aspen wood pretreatment methods with the use of both aqueous solutions of sulfuric and nitric acids and aqueous-organic solutions (ethanol, butanol) of sulfuric acid (organosolv) on the limiting degree of conversion of this type of raw material into simple sugars during enzymatic...

  16. Biosorption of mercury from aqueous solutions using highly characterised peats

    Directory of Open Access Journals (Sweden)

    A.M. Rizzuti

    2015-02-01

    Full Text Available This research investigated the biosorption of mercury from aqueous solutions by six highly characterised peats. Samples of the peats were tested both in unaltered condition and after being treated with hydrochloric acid (HCl to free up any occupied exchange sites. Other variables tested were sample dose, contact time, mixing temperature, and the concentration and pH of the mercury solution. Desorption studies were also performed, and tests were done to determine whether the peats could be re-used for mercury biosorption. The results indicate that all six peat types biosorb mercury from aqueous solutions extremely well (92−100 % removal and that their mercury removal capacities are not significantly affected by manipulation of the various factors tested. The factor that had the greatest impact on the mercury removal capacities of the peats was the pH of the mercury solution. The optimal mercury solution pH for mercury removal was in the range 5−7 for four of the peats and in the range 2−3 for the other two. The desorption results indicate that it may be possible to recover up to 41 % of the removed mercury. All of the peat types tested can be repeatedly re-used for additional mercury biosorption cycles. Hence, their disposal should not become a hazardous waste problem.

  17. Thermodynamics of dilute aqueous solutions of imidazolium based ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Tejwant [Salt and Marine Chemicals Division, Central Salt and Marine Chemicals Research Institute, Council of Scientific and Industrial Research (CSIR), G.B. Marg, Bhavnagar 364002 (India); Kumar, Arvind, E-mail: arvind@csmcri.or [Salt and Marine Chemicals Division, Central Salt and Marine Chemicals Research Institute, Council of Scientific and Industrial Research (CSIR), G.B. Marg, Bhavnagar 364002 (India)

    2011-06-15

    Research highlights: The thermodynamic behaviour of aqueous imidazolium ILs has been investigated. Volumetric and ultrasonic results indicated the hydrophobic hydration of ILs. Viscometric studies revealed studied ionic liquids as water-structure makers. Hydration number increased with increase in alkyl chain length of the cation. - Abstract: Experimental measurements of density {rho}, speed of sound u, and viscosity {eta} of aqueous solutions of various 1-alkyl-3-methylimidazolium based ionic liquid (IL) solutions have been performed in dilute concentration regime at 298.15 K to get insight into hydration behaviour of ILs. The investigated ILs are based on 1-alkyl-3-methylimidazolium cation, [C{sub n}mim] having [BF{sub 4}]{sup -}, [Cl]{sup -}, [C{sub 1}OSO{sub 3}]{sup -}, and [C{sub 8}OSO{sub 3}]{sup -} as anions where n = 4 or 8. Several thermodynamic parameters like apparent molar volume {phi}{sub V}, isentropic compressibility {beta}{sub s}, and viscosity B-coefficients have been derived from experimental data. Limiting value of apparent molar volume has been discussed in terms of intrinsic molar volume (V{sub int}) molar electrostriction volume (V{sub elec}), molar disordered (V{sub dis}), and cage volume (V{sub cage}). Viscosity B-coefficients have been used to quantify the kosmotropic or chaotropic nature of ILs. Hydration number of ILs obtained using elctrostriction volume, isentropic compressibility, viscosity, and differential scanning calorimetry have been found to be comparative within the experimental error. The hydrophobic hydration has found to play an important role in hydration of ILs as compared to hydration due to hydrogen bonding and electrostriction. Limiting molar properties, hydration numbers, and B-coefficients have been discussed in terms of alkyl chain length of cation or nature of anion.

  18. Thermal properties and physicochemical behavior in aqueous solution of pyrene-labeled poly(ethylene glycol-polylactide conjugate

    Directory of Open Access Journals (Sweden)

    Chen WL

    2015-04-01

    Full Text Available Wei-Lin Chen,1,2 Yun-Fen Peng,1,3 Sheng-Kuo Chiang,1 Ming-Hsi Huang1–3 1National Institute of Infectious Diseases and Vaccinology, National Health Research Institutes, Miaoli, Taiwan; 2Graduate Institute of Life Sciences, National Defense Medical Center, Taipei, Taiwan; 3PhD Program in Tissue Engineering and Regenerative Medicine, National Chung Hsing University, Taichung, Taiwan Abstract: A fluorescence-labeled bioresorbable polymer was prepared by a coupling reaction of poly(ethylene glycol-polylactide (PEG-PLA with carboxyl pyrene, using N,N’-diisopropylcarbodiimide/1-hydroxy-7-azabenzotriazole (DIC/HOAt as a coupling agent and 4-dimethylaminopyridine (DMAP as a catalyst. The obtained copolymer, termed PEG-PLA-pyrene, was characterized using various analytical techniques, such as gel permeation chromatography (GPC, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS, proton nuclear magnetic resonance (1H-NMR, infrared spectroscopy (IR, differential scanning calorimetry (DSC, and thermogravimetric analysis (TGA, to identify the molecular structure and to monitor the thermal property changes before and after the reaction. The presence of a pyrene moiety at the end of polylactide (PLA did not alter the crystallization ability of the poly(ethylene glycol (PEG blocks, indicating that the conjugate preserved the inherent thermal properties of PEG-PLA. However, the presence of PEG-PLA blocks strongly reduced the melting of pyrene, indicating that the thermal characteristics were sensitive to PEG-PLA incorporation. Regarding the physicochemical behavior in aqueous solution, a higher concentration of PEG-PLA-pyrene resulted in a higher ultraviolet-visible (UV-vis absorbance and fluorescence emission intensity. This is of great interest for the use of this conjugate as a fluorescence probe to study the in vivo distribution as well as the internalization and intracellular localization of polymeric micelles

  19. Polysaccharide-thickened aqueous fluoride solutions for rapid destruction of the nerve agent VX. Introducing the opportunity for extensive decontamination scenarios.

    Science.gov (United States)

    Elias, Shlomi; Saphier, Sigal; Columbus, Ishay; Zafrani, Yossi

    2014-01-01

    Among the chemical warfare agents, the extremely toxic nerve agent VX (O-ethyl S-2-(diisopropylamino)ethyl methylphosphonothioate) is a target of high importance in the development of decontamination methods, due to its indefinite persistence on common environmental surfaces. Liquid decontaminants are mostly characterized by high corrosivity, usually offer poor coverage, and tend to flow and accumulate in low areas. Therefore, the development of a noncorrosive decontaminant, sufficiently viscous to resist dripping from the contaminated surface, is necessary. In the present paper we studied different polysaccharides-thickened fluoride aqueous solutions as noncorrosive decontaminants for rapid and efficient VX degradation to the nontoxic product EMPA (ethyl methylphosphonic acid). Polysaccharides are environmentally benign, natural, and inexpensive. Other known decontaminants cannot be thickened by polysaccharides, due to the sensitivity of the latter toward basic or oxidizing agents. We found that the efficiency of VX degradation in these viscous solutions in terms of kinetics and product identity is similar to that of KF aqueous solutions. Guar gum (1.5 wt %) with 4 wt % KF was chosen for further evaluation. The benign nature, rheological properties, adhering capabilities to different surfaces, and decontamination from a porous matrix were examined. This formulation showed promising properties for implementation as a spray decontaminant for common and sensitive environmental surfaces.

  20. Pulse radiolysis of pyridine and methylpyridines in aqueous solutions

    DEFF Research Database (Denmark)

    Solar, S.; Getoff, N.; Sehested, K.

    1993-01-01

    The radicals formed from pyridine, 3-methylpyridine, 3,5-dimethylpyridine, 2,6-dimethylpyridine and 2,4,6-trimethylpyridine by attack of H, e(aq)-, OH and O.- in aqueous solutions were investigated by pulse radiolysis in the pH-range 1-13.8. The UV-vis. absorption spectra as well as the formation...

  1. Accurate Description of Calcium Solvation in Concentrated Aqueous Solutions

    Czech Academy of Sciences Publication Activity Database

    Kohagen, Miriam; Mason, Philip E.; Jungwirth, Pavel

    2014-01-01

    Roč. 118, č. 28 (2014), s. 7902-7909 ISSN 1520-6106 R&D Projects: GA ČR GBP208/12/G016; GA MŠk LH12001 Institutional support: RVO:61388963 Keywords : calcium chloride * aqueous solution * molecular dynamics * neutron scattering Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.302, year: 2014

  2. OSMOTIC COEFFICIENTS, SOLUBILITIES, AND DELIQUESCENCE RELATIONS IN MIXED AQUEOUS SALT SOLUTIONS AT ELEVATED TEMPERATURE

    International Nuclear Information System (INIS)

    M.S. Gruszkiewicz; D.A. Palmer

    2006-01-01

    While thermodynamic properties of pure aqueous electrolytes are relatively well known at ambient temperature, there are far fewer data for binary systems extending to elevated temperatures and high concentrations. There is no general theoretically sound basis for prediction of the temperature dependence of ionic activities, and consequently temperature extrapolations based on ambient temperature data and empirical equations are uncertain and require empirical verification. Thermodynamic properties of mixed brines in a wide range of concentrations would enhance the understanding and precise modeling of the effects of deliquescence of initially dry solids in humid air in geological environments and in modeling the composition of waters during heating, cooling, evaporation or condensation processes. These conditions are of interest in the analysis of waters on metal surfaces at the proposed radioactive waste repository at Yucca Mountain, Nevada. The results obtained in this project will be useful for modeling the long-term evolution of the chemical environment, and this in turn is useful for the analysis of the corrosion of waste packages. In particular, there are few reliable experimental data available on the relationship between relative humidity and composition that reveals the eutonic points of the mixtures and the mixture deliquescence RH. The deliquescence RH for multicomponent mixtures is lower than that of pure component or binary solutions, but is not easy to predict quantitatively since the solutions are highly nonideal. In this work we used the ORNL low-temperature and high-temperature isopiestic facilities, capable of precise measurements of vapor pressure between ambient temperature and 250 C for determination of not only osmotic coefficients, but also solubilities and deliquescence points of aqueous mixed solutions in a range of temperatures. In addition to standard solutions of CaCl 2 , LiCl, and NaCl used as references, precise direct

  3. Absorption and recovery of n-hexane in aqueous solutions of fluorocarbon surfactants.

    Science.gov (United States)

    Xiao, Xiao; Yan, Bo; Fu, Jiamo; Xiao, Xianming

    2015-11-01

    n-Hexane is widely used in industrial production as an organic solvent. As an industrial exhaust gas, the contribution of n-hexane to air pollution and damage to human health are attracting increasing attention. In the present study, aqueous solutions of two fluorocarbon surfactants (FSN100 and FSO100) were investigated for their properties of solubilization and dynamic absorption of n-hexane, as well as their capacity for regeneration and n-hexane recovery by thermal distillation. The results show that the two fluorocarbon surfactants enhance dissolution and absorption of n-hexane, and their effectiveness is closely related to their concentrations in solution. For low concentration solutions (0.01%-0.30%), the partition coefficient decreases dramatically and the saturation capacity increases significantly with increasing concentration, but the changes for both are more modest when the concentration is over 0.30%. The FSO100 solution presents a smaller partition coefficient and a greater saturation capacity than the FSN100 solution at the same concentration, indicating a stronger solubilization for n-hexane. Thermal distillation is a feasible method to recover n-hexane from these absorption solutions, and to regenerate them. With 90sec heating at 80-85°C, the recovery of n-hexane ranges between 81% and 85%, and the regenerated absorption solution maintains its original performance during reuse. This study provides basic information on two fluorocarbon surfactants for application in the treatment of industrial n-hexane waste gases. Copyright © 2015. Published by Elsevier B.V.

  4. Pulse radiolysis studies of iron(I) in aqueous solutions

    International Nuclear Information System (INIS)

    Nenadovic, M.T.; Micic, O.I.; Muk, A.A.

    1980-01-01

    The absorption spectrum and decay kinetics of the products of the reactions of iron(II) ions with hydrated electrons and hydrogen atoms have been studied in aqueous solution using pulse-radiolysis techniques. Iron(I) is formed by reaction with hydrated electrons and its absorption spectrum is reported and discussed. The formation of molecular hydrogen by reaction of Fe + with water is suppressed by other solutes present in the solutions. In acidic solutions containing [SO 4 ] 2- , the intermediates formed in the reaction with H atoms decay by a first-order process and produce molecular hydrogen, but the rate of their decay does not depend only on the oxonium ion concentration but also on intermolecular rearrangement in the [FeSO 4 -H] complex. (author)

  5. Cytosine modifications after gamma irradiation in aerated aqueous solution of Escherichia coli DNA

    International Nuclear Information System (INIS)

    Polverelli, M.

    1983-04-01

    After gamma irradiation of cytosine in aerated aqueous solution and utilization of various spectrometric methods (mass spectrometry, proton nuclear magnetic resonance and infrared spectrometry) about ten new radiolysis products were identified. The formation of N-glycolylbiuret in H 2 18 O aqueous solution of irradiated cytosine at pH 4,5 indicated that the preferred 18 OH hydroxyl radical attack was at C-5. The formation of trans 1-carbamoyl-4,5 dihydroxyimidazolidin-2 oxo which is the major product after cytosine pyrimidine ring rearrangement took place preferentially at neutral pH, while N-glycolylbiuret predominated at pH 4,5. The deamination pathway was predominant when cytosine was irradiated at acidic pH values (pH 2 ) or in copper complexes. The development of a new acid hydrolysis method using fluorhydric acid stabilized in pyridine made easier the evaluation of cytosine modifications after gamma irradiation in aerated aqueous solution of E. Coli DNA- 14 C-2 cytosine. This hydrolytic agent removed the modified bases from the polynucleotidic chain. A difference was found between the proportion of radiolytic products removed by acid hydrolysis and by irradiation of the free base in solution [fr

  6. Comparison of cytotoxicity in vitro and irritation in vivo for aqueous and oily solutions of surfactants.

    Science.gov (United States)

    Czajkowska-Kośnik, Anna; Wolska, Eliza; Chorążewicz, Juliusz; Sznitowska, Małgorzata

    2015-01-01

    The in vivo model on rabbit eyes and the in vitro cytotoxicity on fibroblasts were used to compare irritation effect of aqueous and oily (Miglyol 812) solutions of surfactants. Tween 20, Tween 80 and Cremophor EL were tested in different concentrations (0.1, 1 or 5%) and the in vitro test demonstrated that surfactants in oil are less cytotoxic than in aqueous solutions. In the in vivo study, the aqueous solutions of surfactants were characterized as non-irritant while small changes in conjunctiva were observed after application the oily solutions of surfactants and the preparations were classified as slightly irritant, however this effect was similar when Miglyol was applied alone. In conclusion, it is reported that the MTT assay does not correlate well with the Draize scores.

  7. Characterization of aqueous solution of cresol red as food irradiation dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Khan, H M; Tabassum, S; Wahid, M S [Peshawar University, Peshawar (Pakistan). Radiation Chemistry Laboratory, National Centre of Excellence in Physical Chemistry

    2009-06-15

    Dilute aqueous solution of cresol red has been evaluated spectrophotometrically as possible gamma rays dosimeter. A 0.10 mM solution of cresol red was irradiated by gamma rays using a cobalt-60 radiation source. The absorbance spectra of the unirradiated and irradiated solutions were recorded using double beam scanning spectrophotometer. The absorbance of the solution before and after irradiation was measured at 434 nm ({lambda}{sub max}) as well as at other wavelengths (415, 448 and 470 nm). Various parameters, such as Absorbance (A), {delta}A, %A, -log A and log A{sub o}/A{sub i} were plotted against radiation dose, in order to check the response of cresol red solution and its possible use as chemical dosimeter. The response plots of A, {delta}A, and %A versus absorbed dose showed that the solution can be used as a radiation dosimeter in a dose range up to 0.82 kGy. Using response plots of -log A and log A{sub o}/A{sub i}, the useful dose range can be extended up to 1.65 kGy; which are useful dose ranges for food irradiation applications. Stability studies of cresol red solution at different light and temperature conditions for pre- and post-irradiated storage of the dosimetric solutions suggested that aqueous solution of cresol red is highly stable in dark, under fluorescence light and at room temperature up to 150 days (author)

  8. The study of CO2 absorption intensification using porous media material in aqueous AMP solution

    Directory of Open Access Journals (Sweden)

    Min Xiao

    2018-03-01

    Full Text Available In this work, the performance of CO2 absorption into aqueous 2-amino-2-methyl-propanol (AMP solution was investigated by measuring the amount of CO2 in the liquid phase during CO2 absorption process to identify initial CO2 absorption rate. Then, the porous media material named as MCM41 was introduced into the amine solution to test its influence on CO2 absorption. It was found that MCM41 increased initial CO2 absorption rate and enhanced CO2 absorption process. The physico-chemical properties of MCM41 were characterized in terms of specific surface area, average pore diameter, total pore volume and chemical properties, the amount of acidic sites and the Brϕnsted/Lewis (B/L acid sites ratio. Results showed that MCM41 was a type of Lewis acid catalyst with large specific surface area and pore volume. In addition, the pKa of AMP solution with and without MCM41 was obtained using acid titration technology to help understand the effect brought by MCM41. A mechanism illustrating how MCM41 increases the CO2 absorption rate of the AMP solution was proposed and demonstrated that MCM41 is a potential material for enhancing CO2 absorption.

  9. The salting-out effect and phase separation in aqueous solutions of tri-sodium citrate and 1-butyl-3-methylimidazolium bromide

    International Nuclear Information System (INIS)

    Sadeghi, Rahmat; Golabiazar, Roonak; Shekaari, Hemayat

    2010-01-01

    The aim of this work is to obtain further evidence about the salting-out effect produced by the addition of tri-sodium citrate to aqueous solutions of water miscible ionic liquid 1-butyl-3-methylimidazolium bromide ([C 4 mim][Br]) by evaluating the effect of tri-sodium citrate on the thermodynamic properties of aqueous solutions of this ionic liquid. Experimental measurements of density and sound velocity at different temperatures ranging from (288.15 to 308.15) K, the refractive index at 308.15 K and the liquid-liquid phase diagram at different temperatures ranging from (288.15 to 338.15) K for aqueous solutions containing 1-butyl-3-methylimidazolium bromide ([C 4 mim][Br]) and tri-sodium citrate (Na 3 Cit) are taken. The apparent molar volume of transfer of [C 4 mim][Br] from water to aqueous solutions of Na 3 Cit have positive values and it increases by increasing salt molality. Although at high IL molality, the apparent molar isentropic compressibility shows similar behaviour with that of the apparent molar volume. However at low concentrations of IL, the apparent molar isentropic compressibility of transfer of [C 4 mim][Br] from water to aqueous solutions of Na 3 Cit have negative values. The effects of temperature and the addition of Na 3 Cit and [C 4 mim][Br] on the liquid-liquid phase diagram of the investigated system have been studied. It was found that an increase in temperature caused the expansion of the one-phase region. The presence of Na 3 Cit triggers a salting-out effect, leading to significant upward shifts of the liquid-liquid de-mixing temperatures of the system. The effect of temperature on the phase-forming ability in the system investigated has been studied based on a salting-out coefficient obtained from fitting the binodal values to a Setschenow-type equation for each temperature. Based on cloud point values, the energetics of the clouding process have been estimated and it was found that both of entropy and enthalpy are the driving forces

  10. Removal of cadmium from aqueous solution using marine green algae, Ulva lactuca

    Directory of Open Access Journals (Sweden)

    Mohamed M. Ghoneim

    2014-01-01

    Full Text Available The present study aimed to evaluate the efficiency of marine algae for removal of metals from the aqueous solution. The green alga, Ulva lactuca, collected from the intertidal zone of the Suez Bay, northern part of the Red Sea was used to reduce cadmium levels from the aqueous solutions. The biosorption mechanisms of Cd2+ ions onto the algal tissues were examined using various analytical techniques: Fourier-transform infrared spectroscopy (FT-IR and Scanning electron microscopy (SEM. Results indicated that at the optimum pH value of 5.5; about 0.1 g of U. lactuca was enough to remove 99.2% of 10 mg L−1 Cd2+ at 30 °C in the aqueous solutions. The equilibrium data were well fitted with the Langmuir and Freundlich isotherms. The monolayer adsorption capacity was 29.1 mg g−1. The calculated RL and ‘n’ values have proved the favorability of cadmium adsorption onto U. lactuca. The desorption test revealed that HCl was the best for the elution of metals from the tested alga. In conclusion, the seaweed U. lactuca was the favorable alternative of cadmium removal from water.

  11. The blue complexes of U in aqueous solutions

    International Nuclear Information System (INIS)

    Musikas, C.

    1976-01-01

    Mixed-valence uranium complexes were synthesized. Hydrolysis of hexavalent U leads to anionic species soluble in aqueous solutions when the UO 2 ++ ions are neutralized by tetraalkylammonium hydroxides. These complexes are polynuclear and the size and interatomic distances found for the polyanions are those of macromolecules. By hydrazine of these complexes, solutions were obtained and their absorption spectra studied. The spectra of U(VI) and U(V) ions are observed, together with new bands attributable to a charge transfer. It may be concluded that the blue complexes of uranium are type II composite-valence complexes for which the delocalization coefficient α can be calculated [fr

  12. Quantitative Method for the Detection of Triethyl Phosphate in Aqueous Solutions

    National Research Council Canada - National Science Library

    Bagalawis, Rosa

    2003-01-01

    ...) at the parts per million level in aqueous solution. TEP was used as a chemical agent simulant to evaluate the penetration characteristics of clothing, gloves, boots and items of personal equipment...

  13. The kinetics of dye formation by pulse radiolysis of pararosaniline cyanide in aqueous or organic solution

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Holcman, J.; Sehested, K.; Kosanic, M.M.

    1979-11-01

    The radiation-induced conversion of the leucocyanide of pararosaniline dye to the highly colored salt-isomer of the dye in acidic aqueous solution (wavelength of maximum absorption lambda sub(max)=540 nm) or polar organic solution (lambda sub(max)=550 nm), takes place in two separate processes. The first is very fast (within 3 s -1 to 10 6 s -1 , as the acidity or concentration of an oxidizing agent increases. In oxygen-free acidic aqueous or organic solutions (argon saturated) there is an unstable transient species (lambdasub(max)=380 nm). When using O 2 or N 2 O-saturated aqueous or organic solution, there is no intermediate absorption band at 380 nm, but the slow process of dye formation at 540 or 550 nm is still sequential to the initial fast process having somewhat faster kinetics than in Ar-saturated solution. (author)

  14. Removal of lead from aqueous solution on glutamate intercalated layered double hydroxide

    Directory of Open Access Journals (Sweden)

    Shen Yanming

    2017-05-01

    Full Text Available Glutamate intercalated Mg–Al layered double hydroxide (LDH was prepared by co-precipitation and the removal of Pb2+ in the aqueous solution was investigated. The prepared samples were characterized by XRD, FT-IR and SEM. It was shown that glutamate can intercalate into the interlayer space of Mg–Al LDH. The glutamate intercalated Mg–Al LDH can effectively adsorb Pb2+ in the aqueous solution with an adsorption capacity of 68.49 mg g−1. The adsorption of Pb2+ on glutamate intercalated Mg–Al LDH fitted the pseudo-second-order kinetics model and the isotherm can be well defined by Langmuir model.

  15. Comparative study on heat pipe performance using aqueous solutions of alcohols

    Energy Technology Data Exchange (ETDEWEB)

    Senthilkumar, R.; Vaidyanathan, S.; Sivaraman, B. [Annamalai University, Department of Mechanical Engineering, Annamalai Nagar, Tamil Nadu (India)

    2012-12-15

    This paper deals with the performance characterization of heat pipes using an aqueous solution of long chain alcohols like n-Butanol, n-Pentanol, n-Hexanol and n-Heptanol as working mediums. These solutions are called as self-rewetting fluids, since these fluid mixtures possess a non-linear dependence of the surface tension with temperature. A cylindrical heat pipe made up of copper with two layers of wrapped screen is used as a wick material and partially filled with the self-rewetting fluid water mixture and tested for its heat transport capability like thermal efficiency and thermal resistance at different inclinations and input power levels. A number of tests have been performed with heat pipes, filled with various aqueous solutions of alcohols with a concentration of 2 ml/l in de-ionized water (DI water) on volume basis. The results obtained for heat pipes using self rewetting fluids show improved performances, when compared to DI water heat pipes. (orig.)

  16. Study of free acidity determinations in aqueous solution; Etude des dosages d'acidite libre en solution aqueuse

    Energy Technology Data Exchange (ETDEWEB)

    Kergreis, A [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1966-04-01

    The object of this work is the study of the principal methods which can be applied to the measurement of 'free' acidity. In the first part, we define the various types of acidity which can exist in aqueous solution; then, after having studied some hydrolysis reactions, we compare the value of the neutralisation pH of the hydrated cation and that of the precipitation of the hydroxide. In the second part we have started to study the determination of the acidity of an aqueous solution. After having rapidly considered the 'total' acidity determination, we deal with the problem of the 'free' acidity titration. We have considered in particular certain methods: extrapolation of the equivalent point, colorimetric titrations with or without a complexing agent, and finally the use of ion-exchange resins with mixed aqueous and solvent solutions. (author) [French] Le but de ce travail est l'etude des principales methodes de determination de l'acidite 'libre'. Dans une premiere partie nous avons defini les differentes sortes d'acidites pouvant exister en solution aqueuse, puis apres avoir etudie quelques reactions d'hydrolyse, nous avons compare la valeur de pH de neutralisation du cation hydrate et celle de precipitation de l'hydroxyde. Dans la seconde partie nous avons aborde l'etuce des dosages de l'acidite d'une solution aqueuse. Apres avoir envisage assez rapidement la determination de l'acidite 'totale', nous traitons du probleme du titrage de l'acidite 'libre'. Nous avons porte notre attention sur certaines methodes: extrapolation du point equivalent, titrimetrie colorimetrique avec ou sans complexant, et enfin utilisation des resines echangeuses d'ions en milieu aqueux et solvant mixte.

  17. Theoretical calculations of the thermodynamic stability of ionic substitutions in hydroxyapatite under an aqueous solution environment

    International Nuclear Information System (INIS)

    Matsunaga, Katsuyuki; Murata, Hidenobu; Shitara, Kazuki

    2010-01-01

    Defect formation energies in materials generally depend on chemical potentials determined by a chemical equilibrium condition. In particular, an aqueous solution environment is important for biomaterials such as hydroxyapatite studied here. Therefore, a methodology to obtain ionic chemical potentials under chemical equilibrium between solid and aqueous solution was introduced, and was applied to substitutional divalent cations formed via ion exchange with Ca 2+ in hydroxyapatite. The calculated ranking of the stability of substitutional cations in HAp was in good agreement with the experimentally observed trend. The present theoretical approach would be useful to explore the thermodynamic stability of defects in materials subjected to an aqueous solution environment.

  18. Effective adsorption and collection of cesium from aqueous solution using graphene oxide grown on porous alumina

    Science.gov (United States)

    Entani, Shiro; Honda, Mitsunori; Shimoyama, Iwao; Li, Songtian; Naramoto, Hiroshi; Yaita, Tsuyoshi; Sakai, Seiji

    2018-04-01

    Graphene oxide (GO) with a large surface area was synthesized by the direct growth of GO on porous alumina using chemical vapor deposition to study the Cs adsorption mechanism in aqueous solutions. Electronic structure analysis employing in situ near-edge X-ray absorption fine structure spectroscopy and X-ray photoelectron spectroscopy measurements clarifies the Cs atoms bond via oxygen functional groups on GO in the aqueous solution. The Cs adsorption capacity was found to be as high as 650-850 mg g-1, which indicates that the GO/porous alumina acts as an effective adsorbent with high adsorption efficiency for radioactive nuclides in aqueous solutions.

  19. Behavior of supercooled aqueous solutions stemming from hidden liquid-liquid transition in water.

    Science.gov (United States)

    Biddle, John W; Holten, Vincent; Anisimov, Mikhail A

    2014-08-21

    A popular hypothesis that explains the anomalies of supercooled water is the existence of a metastable liquid-liquid transition hidden below the line of homogeneous nucleation. If this transition exists and if it is terminated by a critical point, the addition of a solute should generate a line of liquid-liquid critical points emanating from the critical point of pure metastable water. We have analyzed thermodynamic consequences of this scenario. In particular, we consider the behavior of two systems, H2O-NaCl and H2O-glycerol. We find the behavior of the heat capacity in supercooled aqueous solutions of NaCl, as reported by Archer and Carter [J. Phys. Chem. B 104, 8563 (2000)], to be consistent with the presence of the metastable liquid-liquid transition. We elucidate the non-conserved nature of the order parameter (extent of "reaction" between two alternative structures of water) and the consequences of its coupling with conserved properties (density and concentration). We also show how the shape of the critical line in a solution controls the difference in concentration of the coexisting liquid phases.

  20. Relaxation of the silver/silver iodide electrode in aqueous solution

    NARCIS (Netherlands)

    Peverelli, K.J.

    1979-01-01

    The aim of this study is to detect and characterize relaxation processes on silver/silver iodide electrodes in aqueous electrolyte solution. The information obtained is to be used for an estimation of the consequences of similar processes on colloidal AgI

  1. Radiation dechlorination of PCE in aqueous solutions under various conditions

    International Nuclear Information System (INIS)

    Mucka, V.; Lizalova, B.; Pospisil, M.; Silber, R.; Polakova, D.

    2002-01-01

    Complete text of publication follows. Radiation technology of water purification from chlorinated compounds seems to be one of the promising method (Getoff, 1996), analogously as it was shown (Mueka et al., 2000) with radiation degradation of polychlorinated biphenyls (PCBs). A systematic study of dechlorination of tetrachloroethylene (PCE) in aqueous solutions (initial concentrations ranging from 9.2 x 10 -6 to 2.5 x 10 -4 mol dm -3 ), initiated by γ-rays of 60 Co or by accelerated electrons (EB, 4.5 MeV) in presence of various modifiers (atmospheric oxygen, N 2 O-oxide, HCO 3 - - and NO 3 - - ions as well as various pH-values), was the aim of this paper. The studies showed that both actual concentration c of PCE and radiation yield G(Cl - ) decreased rapidly with increasing dose up to the dose of 2 kGy and the degree of dechlorination raised sharply in this dose-interval. The dechlorination was slightly promoted by atmospheric oxygen. Similarly, a promotion effect was detected in the case of the PCE-solutions saturated, prior to their irradiation, with the N 2 O-oxide. On the other hand, a presence of NO 3 - - or HCO 3 - -ions in irradiated samples led to an inhibiting effect. The inhibiting effect increased markedly with increasing concentration of both at above-mentioned ions up to the concentration of about 100 mg dm -3 . A pronounced inhibition of γ-radiation dechlorination of PCE was observed in alkaline aqueous solutions. The results obtained in this paper support the idea that the radiation dechlorination of PCE in aqueous solutions proceeds via an oxidative mechanism in which the γ-irradiation was found to be more effective than the EB-irradiation

  2. Hybrid Silk Fibers Dry-Spun from Regenerated Silk Fibroin/Graphene Oxide Aqueous Solutions.

    Science.gov (United States)

    Zhang, Chao; Zhang, Yaopeng; Shao, Huili; Hu, Xuechao

    2016-02-10

    Regenerated silk fibroin (RSF)/graphene oxide (GO) hybrid silk fibers were dry-spun from a mixed dope of GO suspension and RSF aqueous solution. It was observed that the presence of GO greatly affect the viscosity of RSF solution. The RSF/GO hybrid fibers showed from FTIR result lower β-sheet content compared to that of pure RSF fibers. The result of synchrotron radiation wide-angle X-ray diffraction showed that the addition of GO confined the crystallization of silk fibroin (SF) leading to the decrease of crystallinity, smaller crystallite size, and new formation of interphase zones in the artificial silks. Synchrotron radiation small-angle X-ray scattering also proved that GO sheets in the hybrid silks and blended solutions were coated with a certain thickness of interphase zones due to the complex interaction between the two components. A low addition of GO, together with the mesophase zones formed between GO and RSF, enhanced the mechanical properties of hybrid fibers. The highest breaking stress of the hybrid fibers reached 435.5 ± 71.6 MPa, 23% improvement in comparison to that of degummed silk and 72% larger than that of pure RSF silk fiber. The hybrid RSF/GO materials with good biocompatibility and enhanced mechanical properties may have potential applications in tissue engineering, bioelectronic devices, or energy storage.

  3. True atomic-scale imaging of a spinel Li{sub 4}Ti{sub 5}O{sub 12}(111) surface in aqueous solution by frequency-modulation atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kitta, Mitsunori, E-mail: m-kitta@aist.go.jp; Kohyama, Masanori [Research Institute for Ubiquitous Energy Devices, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan); Onishi, Hiroshi [Department of Chemistry, Graduate School of Science, Kobe University 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan)

    2014-09-15

    Spinel-type lithium titanium oxide (LTO; Li{sub 4}Ti{sub 5}O{sub 12}) is a negative electrode material for lithium-ion batteries. Revealing the atomic-scale surface structure of LTO in liquid is highly necessary to investigate its surface properties in practical environments. Here, we reveal an atomic-scale image of the LTO(111) surface in LiCl aqueous solution using frequency-modulation atomic force microscopy. Atomically flat terraces and single steps having heights of multiples of 0.5 nm were observed in the aqueous solution. Hexagonal bright spots separated by 0.6 nm were also observed on the flat terrace part, corresponding to the atomistic contrast observed in the ultrahigh vacuum condition, which suggests that the basic atomic structure of the LTO(111) surface is retained without dramatic reconstruction even in the aqueous solution.

  4. The Pd-catalyzed hydrodechlorination of chlorophenols in aqueous solutions under mild conditions: A promising approach to practical use in wastewater

    International Nuclear Information System (INIS)

    Xia Chuanhai; Liu Ying; Zhou Shiwei; Yang Cuiyun; Liu Sujing; Xu Jie; Yu Junbao; Chen Jiping; Liang Xinmiao

    2009-01-01

    Catalytic hydrotreating of chlorophenols was carried out in water with Pd/C at 25 deg. C under atmospheric pressure. 1.0% (w/w) monocholophenols was completely dechlorinated within 60 min. Phenol, cyclohexanone and cyclohexanol were formed. In contrast to the dechlorination of monochlorophenols, the hydrogenation reaction of polychlorinated phenols became difficult and reaction rates were strongly dependent upon the number of the chlorine atoms. The solvent property had a considerably important influence on the dechlorination reaction. Water as a solvent showed more advantages than organic solvents. It was much easier to be hydrodechlorinated for chlorophenols in aqueous solutions. However, the presence of THF, dioxane, DMSO or DMF in water was disadvantageous to the reaction and easily to cause Pd/C deactivation. Additionally, when different halogenated organic compounds were present in aqueous solution, the dehalogenation reaction was the competitive hydrogenation process.

  5. The Pd-catalyzed hydrodechlorination of chlorophenols in aqueous solutions under mild conditions: A promising approach to practical use in wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Xia Chuanhai, E-mail: chuanhaixia@gmail.com [Yantai Institute of Coastal Zone Research for Sustainable Development, CAS, Yantai 264003 (China); Liu Ying; Zhou Shiwei; Yang Cuiyun; Liu Sujing [Yantai Institute of Coastal Zone Research for Sustainable Development, CAS, Yantai 264003 (China); Xu Jie [Dalian Institute of Chemical Physics, CAS, Dalian, 116021 (China); Yu Junbao [Yantai Institute of Coastal Zone Research for Sustainable Development, CAS, Yantai 264003 (China); Chen Jiping; Liang Xinmiao [Dalian Institute of Chemical Physics, CAS, Dalian, 116021 (China)

    2009-09-30

    Catalytic hydrotreating of chlorophenols was carried out in water with Pd/C at 25 deg. C under atmospheric pressure. 1.0% (w/w) monocholophenols was completely dechlorinated within 60 min. Phenol, cyclohexanone and cyclohexanol were formed. In contrast to the dechlorination of monochlorophenols, the hydrogenation reaction of polychlorinated phenols became difficult and reaction rates were strongly dependent upon the number of the chlorine atoms. The solvent property had a considerably important influence on the dechlorination reaction. Water as a solvent showed more advantages than organic solvents. It was much easier to be hydrodechlorinated for chlorophenols in aqueous solutions. However, the presence of THF, dioxane, DMSO or DMF in water was disadvantageous to the reaction and easily to cause Pd/C deactivation. Additionally, when different halogenated organic compounds were present in aqueous solution, the dehalogenation reaction was the competitive hydrogenation process.

  6. Rates of Decomposition of N-Chloramine Disinfectant Compounds in Aqueous Solutions

    International Nuclear Information System (INIS)

    EI-Bellihi, E.E.

    2009-01-01

    The effect of temperature, ph, and salt effects on the decomposition kinetics of hydrolysis of N-chloramine disinfectant compounds [chloramine-B, chloramine-T, N-chlorosuccinimide (NCS), and 1,3-dichloro-5,5-dimethyl hydantoin (DCDMH or Halane)] in aqueous solutions was studied. The results should that the hydrolytic stability of CB and CT is greater than that of NCS and halane. Using CT, which is practical in use for its long contact times, reduced its initial concentration in aqueous solution from 100 ppm to about 20 ppm after a period of 6 months. The study also showed that the rate of hydrolysis of NCS is almost independent on the H + ions concentration. On the other hand, the rates of hydrolysis of CB and CT depend strongly on the hydrogen ion (H + ) concentration where the kinetic of the reaction changes from zero-order to a first order. The thermodynamic parameters of activation were calculated and showed that the entropies of activation have large negative values due to the increase in electrostriction and in a loss of freedom of the solvent water molecules associated with the separation of ions in the transition state. A linear compensation between ΔH and ΔS suggests that in the pure aqueous solutions, the reaction mechanism is almost the same for all the chloramine compounds under investigation

  7. Correlation and Prediction of Thermal Properties and Phase Behaviour for a Class of Aqueous Electrolyte Systems

    DEFF Research Database (Denmark)

    Thomsen, Kaj; Rasmussen, Peter; Gani, Rafiqul

    1996-01-01

    An extended UNIQUAC model is used to describe phase behaviour (VLE, SLE) and thermal properties (heat of mixing, heat capacity) for aqueous solutions containing ions like (Na+, K+, H+) (Cl-, NO3-, SO42-, OH-, CO3-). A linear temperature dependence of the binary interaction parameters allows good...... agreement with experimental data in the temperature range 0-110 degrees C. Copyright (C) 1996 Elsevier Science Ltd...

  8. Improvement of mechanical properties of hydrogel by irradiation of polymers in aqueous solution with κ-carrageenan

    International Nuclear Information System (INIS)

    Makuuchi, K.; Yoshii, F.; Zhai, M.

    2000-01-01

    Predominate radiation reaction of κ-carrageenan (KC) hydrogel is the main chain scission of KC. The gel strength of KC hydrogel decreased with increasing irradiation dose. However, KC was found to enhances the radiation crosslinking of synthetic water-soluble polymer (SWSP) such as poly(ethylene oxide) (PEO) and poly(N-vinylpyrolidone) (PVP) in aqueous solution. The gel strength of SWSP hydrogel increased with increasing dose when KC was blended. Probably the radiation degraded KC radicals are recombined with radicals of PVP and PEO. The hydrogel thus prepared absorbs huge amounts of water due to the presence of strong hydrophilic -OSO 3 - groups in KC. (author)

  9. Improvement of mechanical properties of hydrogel by irradiation of polymers in aqueous solution with {kappa}-carrageenan

    Energy Technology Data Exchange (ETDEWEB)

    Makuuchi, K.; Yoshii, F. [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Aranilla, C.T. [Philippine Nuclear Research Institute, Diliman, Quezon (Philippines); Zhai, M. [Department of Technical Physics, Peking Univ., Beijing (China)

    2000-03-01

    Predominate radiation reaction of {kappa}-carrageenan (KC) hydrogel is the main chain scission of KC. The gel strength of KC hydrogel decreased with increasing irradiation dose. However, KC was found to enhances the radiation crosslinking of synthetic water-soluble polymer (SWSP) such as poly(ethylene oxide) (PEO) and poly(N-vinylpyrolidone) (PVP) in aqueous solution. The gel strength of SWSP hydrogel increased with increasing dose when KC was blended. Probably the radiation degraded KC radicals are recombined with radicals of PVP and PEO. The hydrogel thus prepared absorbs huge amounts of water due to the presence of strong hydrophilic -OSO{sub 3}{sup -} groups in KC. (author)

  10. Surface properties of aqueous amino acid solutions II. Leucine-leucine hydrochloride and leucine-sodium leucinate mixtures.

    Science.gov (United States)

    Matubayasi, Norihiro; Matsuyama, Shohei; Akizuki, Ryosuke

    2005-08-15

    To understand the distinction between the effects of zwitterionic, anionic, and cationic l-leucine upon adsorption and lateral interactions at air/water surface, the surface tensions of aqueous solutions of l-leucine-l-leucine hydrochloride and l-leucine-sodium l-leucinate mixtures were measured as a function of concentration and composition at 25 degrees C. The surface activity decreases in the order l-leucine >l-leucine hydrochloride > sodium l-leucinate. Both l-leucine hydrochloride and sodium l-leucinate form gaseous adsorbed films through the experimentally accessible concentration range, while the adsorbed film of zwitterionic l-leucine shows a transition between gaseous and expanded film.

  11. Chemical metallization of KMPR photoresist polymer in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Zeb, Gul [MiQro Innovation Collaborative Centre (C2MI), 45, boul. de l' Aéroport, Bromont, QC, J2L 1S8 (Canada); Mining & Materials Engineering, McGill University, 3610,University Street, Montreal, QC, H3A 0C5 (Canada); Duong, Xuan Truong [Department of Mechanical Engineering, Ecole polytechnique de Montréal, Montréal, QC, H3C 3T5 (Canada); Thai Nguyen University of Technology, 3-2 Street, Thai Nguyen City (Viet Nam); Vu, Ngoc Pi; Phan, Quang The; Nguyen, Duc Tuong; Ly, Viet Anh [Thai Nguyen University of Technology, 3-2 Street, Thai Nguyen City (Viet Nam); Salimy, Siamak [ePeer Review LLC, 145 Pine Haven Shores Rd, Suite 1000-X, Shelburne, VT 05482 (United States); Le, Xuan Tuan, E-mail: xuantuan.le@teledyne.com [MiQro Innovation Collaborative Centre (C2MI), 45, boul. de l' Aéroport, Bromont, QC, J2L 1S8 (Canada); Thai Nguyen University of Technology, 3-2 Street, Thai Nguyen City (Viet Nam)

    2017-06-15

    Highlights: • Electroless deposition of Ni-B film on KMPR photoresist polymer insulator with excellent adhesion has been achieved. • This metallization has been carried out in aqueous solutions at low temperature. • Polyamine palladium complexes grafts serve as seeds for the electroless plating on KMPR. • This electroless metallization process is simple, industrially feasible, chromium-free and environment-friendly. - Abstract: While conventional methods for preparing thin films of metals and metallic alloys on insulating substrates in the field of microelectromechanical systems (MEMS) include vapor deposition techniques, we demonstrate here that electroless deposition can be considered as an alternate efficient approach to metallize the surface of insulating substrates, such as KMPR epoxy photoresist polymer. In comparison with the physical and chemical vapor deposition methods, which are well-established for metallization of photoresist polymers, our electroless nickel plating requires only immersing the substrates into aqueous solutions in open air at low temperatures. Thin films of nickel alloy have been deposited electrolessly on KMPR surface, through a cost-effective and environmental chromium-free process, mediated through direct grafting of amine palladium complexes in aqueous medium. This covalent organic coating provides excellent adhesion between KMPR and the nickel film and allows better control of the palladium catalyst content. Covalent grafting and characterization of the deposited nickel film have been carried out by means of Fourier-transform infrared spectroscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy techniques.

  12. Effect of ionic strength on the kinetics of ionic and micellar reactions in aqueous solution

    International Nuclear Information System (INIS)

    Dung, M.H.; Kozak, J.J.

    1982-01-01

    The effect of electrostatic forces on the rate of reaction between ions in aqueous solutions of intermediate ionic strength is studied in this paper. We consider the kinetics of reactions involving simple ionic species (1--1 and 2--2 electrolyte systems) as well as kinetic processes mediated by the presence of micellar ions (or other charged organizates). In the regime of ionic strength considered, dielectric saturation of the solvent in the vicinity of the reacting ions must be taken into account and this is done by introducing several models to describe the recovery of the solvent from saturation to its continuum dielectric behavior. To explore the effects of ion size, charge number, and ionic strength on the overall rate constant for the process considered, we couple the traditional theory of ionic reactions in aqueous solution with calculations of the electrostatic potential obtained via solution of the nonlinear Poisson--Boltzmann equation. The great flexibility of the nonlinear Poisson--Boltzmann theory allows us to explore quantitatively the influence of each of these effects, and our simulations show that the short-range properties of the electrostatic potential affect primarily kinetically controlled processes (to varying degrees, depending on the ionic system considered) whereas the down-range properties of the potential play a (somewhat) greater role in influencing diffusion-controlled processes. A detailed examination is made of ionic strength effects over a broad range of ionic concentrations. In the regime of low ionic strength, the limiting slope and intercept of the curve describing the dependence of log k/sub D/ on I/sup 1/2//(1+I/sup 1/2/) may differ considerably from the usual Debye--Hueckel limiting relations, depending on the particular model chosen to describe local saturation effects

  13. Chemical systems in aqueous solutions for using in the holographic ionizing radiation

    International Nuclear Information System (INIS)

    Nicolau-Rebigan, S.

    1979-01-01

    Some types of chemical systems in aqueous solutions for utilization as active media in holographic ionizing radiation dosimeter are presented. One discussed some advantages of the holographic dosimeter comparatively with another existing types. It is outlined the advantages of using aqueousss solutions as active media in holographic dosimeter. (author)

  14. Electroerosion of metal in aqueous solution for sample introduction into an inductively coupled plasma mass spectrometer

    International Nuclear Information System (INIS)

    Goltz, Douglas; Boileau, Michael; Reinfelds, Gundars

    2003-01-01

    When high current (1-10 A cm -2 ) is applied between two conductive samples (metals) in aqueous solution, electroerosion occurs on the surface as a result of electrolysis and possibly collisions of dissolved ions with the metal surface. The power supply for the electroerosion apparatus in this work was a modified spark source unit. Current could be varied in intervals of 2.5, 5 and 10 A in either half-wave (unipolar) or full-wave (bipolar) output. The electroeroded metal forms a colloidal suspension in aqueous solution with particle sizes of the order of 1-10 μm and possibly larger. The suspension is readily dissolved using a small amount (100 μl) of concentrated acid (HCl or HNO 3 ) prior to analysis. Electroerosion of steel and brass in aqueous solution is described both for rapid sample dissolution and as a solid sampling approach for ICP-MS. Some of the electroerosion properties described in this paper include rates of erosion as a function of gap between the conductive samples and solution conductivity. Rates of electroerosion decreased from 120 to 30 μg s -1 as the gap was increased from 2 to 5 mm. Rates of electroerosion also increased significantly from 200 to 1000 μg s -1 as the conductivity of the electroerosion solution increased from 0.01 to 0.05 M NaCl. Interfacing the electroerosion apparatus to an ICP-MS was straight forward, as no special equipment was required. Therefore, the electroerosion apparatus can be used for rapid 'on-line' sample dissolution prior to introduction into an ICP. ICP-MS time profiles of selected metals in stainless steel 308L illustrate the behavior of 52 Cr + , 55 Mn + and 60 Ni + during a typical electroerosion cycle. Aspiration of the colloidal suspension into the ICP did not appear to load the plasma significantly, however, all of the metals produced noisy signals (±10%). A glass concentric nebulizer was used without clogging, so it is likely that the heterogeneous nature of the colloidal suspension caused this effect

  15. Electroerosion of metal in aqueous solution for sample introduction into an inductively coupled plasma mass spectrometer

    Science.gov (United States)

    Goltz, Douglas; Boileau, Michael; Reinfelds, Gundars

    2003-07-01

    When high current (1-10 A cm -2) is applied between two conductive samples (metals) in aqueous solution, electroerosion occurs on the surface as a result of electrolysis and possibly collisions of dissolved ions with the metal surface. The power supply for the electroerosion apparatus in this work was a modified spark source unit. Current could be varied in intervals of 2.5, 5 and 10 A in either half-wave (unipolar) or full-wave (bipolar) output. The electroeroded metal forms a colloidal suspension in aqueous solution with particle sizes of the order of 1-10 μm and possibly larger. The suspension is readily dissolved using a small amount (100 μl) of concentrated acid (HCl or HNO 3) prior to analysis. Electroerosion of steel and brass in aqueous solution is described both for rapid sample dissolution and as a solid sampling approach for ICP-MS. Some of the electroerosion properties described in this paper include rates of erosion as a function of gap between the conductive samples and solution conductivity. Rates of electroerosion decreased from 120 to 30 μg s -1 as the gap was increased from 2 to 5 mm. Rates of electroerosion also increased significantly from 200 to 1000 μg s -1 as the conductivity of the electroerosion solution increased from 0.01 to 0.05 M NaCl. Interfacing the electroerosion apparatus to an ICP-MS was straight forward, as no special equipment was required. Therefore, the electroerosion apparatus can be used for rapid 'on-line' sample dissolution prior to introduction into an ICP. ICP-MS time profiles of selected metals in stainless steel 308L illustrate the behavior of 52Cr +, 55Mn + and 60Ni + during a typical electroerosion cycle. Aspiration of the colloidal suspension into the ICP did not appear to load the plasma significantly, however, all of the metals produced noisy signals (±10%). A glass concentric nebulizer was used without clogging, so it is likely that the heterogeneous nature of the colloidal suspension caused this effect.

  16. Removal of phosphate and nitrate from aqueous solution using ...

    African Journals Online (AJOL)

    sunny t

    water, 3.5 g of NaCl were dissolved to obtain 3.5 g/l salinity final solution. When the ... The nitrate adsorption was highly pH dependent, which affects the ... adsorption mechanism that the optimum pH for phosphate removal by .... Biosorption of copper(ii) from aqueous ... Accumulation and detoxification of toxic elements by ...

  17. Study of iodine-iodate isotopic exchange reaction in neutral aqueous solutions by radiotracer technique

    International Nuclear Information System (INIS)

    Tripathi, R.; Ram, K.D.

    1993-01-01

    The isotopic exchange of iodine atoms in neutral aqueous solutions of iodate ions and iodine (in KI) is found to obey the rate law R = k [IO 3 - ] 0.4 [I 2 ] 1.2 at 175 o C. The addition of neutral ionic salts, e.g. KCl and KNO 3 , in the reaction mixture showed a slight catalytic effect on the exchange rate. Further, the kinetic salt effect indicated the involvement of at least one neutral species on the rate-determining step. The activation energy in neutral aqueous solutions of iodate ions and iodine is found to be 86 ± 3 kJ mol -1 , which decreases in the presence of KCl (79 ± 3 kJ mol -1 and KNO 3 (82 + 3 kJ mol -1 ). The activation parameters, viz. free energy of activation, enthalpy of activation and entropy of activation, were also calculated. Based on these results, an association-dissociation type of reaction mechanism is proposed for this exchange reaction in neutral aqueous medium, similar to that proposed earlier for iodide-iodate isotopic exchange reaction in neutral aqueous solutions, nitrate eutectic melts and iodide-iodate melts. (author)

  18. Experiment and model for the surface tension of amine–ionic liquids aqueous solutions

    International Nuclear Information System (INIS)

    Zhang, Pan; Du, LeiXia; Fu, Dong

    2014-01-01

    Highlights: • The surface tensions of MEA/DEA–ionic liquids aqueous solutions were measured. • The experiments were modeled satisfactorily by using a thermodynamic equation. • The temperature dependence of the surface tension was illustrated. • The effects of the mass fractions of MEA/DEA and ionic liquids were demonstrated. - Abstract: The surface tension (γ) of 1-butyl-3-methylimidazolium tetrafluoroborate ([Bmim][BF 4 ])–monoethanolamine (MEA), 1-butyl-3-methylimidazolium bromide ([Bmim][Br])–MEA, [Bmim][BF 4 ]–diethanolamine (DEA) and [Bmim][Br]–DEA aqueous solutions was measured by using the BZY-1 surface tension meter. The temperature ranged from (293.2 to 323.2) K. The mass fraction of amines and ionic liquids (ILS) respectively ranged from 0.15 to 0.30 and 0.05 to 0.10. A thermodynamic equation was proposed to model the surface tension of amines–ILS aqueous solutions and the calculated results agreed well with the experiments. The effects of temperature, mass fraction of amines and ILS on the surface tension were demonstrated on the basis of experiments and calculations

  19. Four-photon Rayleigh-wing spectroscopy of the aqueous solution of α-chymotrypsin protein

    International Nuclear Information System (INIS)

    Bunkin, Aleksei F; Nurmatov, Alisher A; Pershin, Sergei M; Lebedenko, S I

    2006-01-01

    The spectra of coherent librations of H 2 O molecules, coinciding in frequencies with the rotational spectrum of gaseous H 2 O, are observed for the first time in aqueous solutions of α-chymotrypsin protein and hydrogen peroxide and in deionised Milli-Q water by the method of four-photon laser scattering in the frequency range 0-100 cm -1 . The resonance contribution of molecular librations to the four-photon scattering signal considerably increases in aqueous solutions compared to water. The resonances related to the lines of the ortho- and para-modifications of the natural isotope of the H 2 O molecule in the gas phase are recorded in the four-photon scattering spectra. It is found that the protein molecule in aqueous solution selectively interacts with the para-H 2 O, which makes it possible to interpret some features of the interaction of microwave radiation with biological objects and to develop a new class of laser biotechnologies. (special issue devoted to the 90th anniversary of a.m. prokhorov)

  20. Electrodeposition of tantalum on carbon black in non-aqueous solution and its electrocatalytic properties

    International Nuclear Information System (INIS)

    Jo, Ara; Lee, Youngmi; Lee, Chongmok

    2016-01-01

    In this work, we synthesized tantalum (Ta) nanoclusters on carbon black (Ta/CB) via simple electrodeposition in non-aqueous solvent, acetonitrile (ACN) at ambient temperature. Transmission electron microscopy (TEM) images showed that the electrodeposited Ta nanoclusters consisted of tiny Ta nanoparticles. X-ray photoelectron spectroscopy (XPS) result represented that the outermost Ta formed the native oxide on Ta/CB due to its ambient exposure to air. Electrochemical catalytic properties of prepared Ta/CB on glassy carbon electrode (Ta/CB/GC) were investigated toward reductions of oxygen and hydrogen peroxide, and oxidations of ascorbic acid and dopamine. For oxygen reduction reaction (ORR) in acid, Ta/CB/GC represented a decent electrocatalytic performance which was better or comparable to bare Pt. The operational stability in acidic condition was maintained up to 500 repetitive potential cycles presumably due to the protective native Ta oxide layer. Ta/CB/GC also showed high amperometric sensitivity (4.5 (±0.1_6) mA mM"−"1 cm"−"2, n = 5) for reduction of hydrogen peroxide in 0.1 M phosphate buffer solution (PBS, pH 7.4). In addition, Ta/CB/GC was demonstrated for the possibility of simultaneous detection of ascorbic acid and dopamine using differential pulse voltammetry (DPV). - Highlights: • We electrodeposited Ta nanoclusters (Ta/CB/GC) in acetonitrile at room temperature. • The Ta/CB/GC showed better or comparable performance to bare Pt for ORR. • The Ta/CB/GC showed high sensitivity for reduction of hydrogen peroxide at pH 7.4. • The Ta/CB/GC showed possible simultaneous detection of ascorbic acid and dopamine. • We extended the applicability of Ta electrode material for various electrocatalytic reactions.

  1. Electrodeposition of tantalum on carbon black in non-aqueous solution and its electrocatalytic properties

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Ara; Lee, Youngmi, E-mail: youngmilee@ewha.ac.kr; Lee, Chongmok, E-mail: cmlee@ewha.ac.kr

    2016-08-24

    In this work, we synthesized tantalum (Ta) nanoclusters on carbon black (Ta/CB) via simple electrodeposition in non-aqueous solvent, acetonitrile (ACN) at ambient temperature. Transmission electron microscopy (TEM) images showed that the electrodeposited Ta nanoclusters consisted of tiny Ta nanoparticles. X-ray photoelectron spectroscopy (XPS) result represented that the outermost Ta formed the native oxide on Ta/CB due to its ambient exposure to air. Electrochemical catalytic properties of prepared Ta/CB on glassy carbon electrode (Ta/CB/GC) were investigated toward reductions of oxygen and hydrogen peroxide, and oxidations of ascorbic acid and dopamine. For oxygen reduction reaction (ORR) in acid, Ta/CB/GC represented a decent electrocatalytic performance which was better or comparable to bare Pt. The operational stability in acidic condition was maintained up to 500 repetitive potential cycles presumably due to the protective native Ta oxide layer. Ta/CB/GC also showed high amperometric sensitivity (4.5 (±0.1{sub 6}) mA mM{sup −1} cm{sup −2}, n = 5) for reduction of hydrogen peroxide in 0.1 M phosphate buffer solution (PBS, pH 7.4). In addition, Ta/CB/GC was demonstrated for the possibility of simultaneous detection of ascorbic acid and dopamine using differential pulse voltammetry (DPV). - Highlights: • We electrodeposited Ta nanoclusters (Ta/CB/GC) in acetonitrile at room temperature. • The Ta/CB/GC showed better or comparable performance to bare Pt for ORR. • The Ta/CB/GC showed high sensitivity for reduction of hydrogen peroxide at pH 7.4. • The Ta/CB/GC showed possible simultaneous detection of ascorbic acid and dopamine. • We extended the applicability of Ta electrode material for various electrocatalytic reactions.

  2. Influence of electric field on the properties of the polymer stabilized luminescent quantum dots in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Zharkova, Irina S.; Markina, Natalia E. [Saratov State University, Astrakhanskaya 83, 410012 Saratov (Russian Federation); Markin, Alexey V., E-mail: av_markin@mail.ru [Saratov State University, Astrakhanskaya 83, 410012 Saratov (Russian Federation); Drozd, Daniil D.; Speranskaya, Elena S. [Saratov State University, Astrakhanskaya 83, 410012 Saratov (Russian Federation); Goryacheva, Irina Yu. [Saratov State University, Astrakhanskaya 83, 410012 Saratov (Russian Federation); Saint-Petersburg State University, Universitetskii pr. 26, 198504 Petrodvorets, Saint-Petersburg (Russian Federation)

    2016-08-15

    The application of external electric field for verification of quantum dots (QDs) stability in aqueous medium was proposed. Hydrophilic CdSe core-shell nanocrystals were synthesized and used with three polymer-based organic stabilizers, two of which contain PEG chains. An increasing of the stability under applied electric field (EF) was shown for stabilizer containing higher amount of PEG chains and terminal amino-groups: introduction of additional PEG chains allowed reducing degradation of luminescence intensity for about 60%. The changes of QDs solutions after EF treatment were examined by dynamic light scattering measurements, luminescence and absorbance spectroscopy, and conductivity measurements and explained by decreasing of quantum yield of the samples due to degradation of stabilizer coating. - Highlights: • Hydrophilic QDs with three types of stabilizer coatings were prepared and treated by electric field in water environment. • Permanent QDs luminescence quenching in aqueous medium under low electric field strength was observed. • Luminescence stability to EF treatment increases by stabilizer with higher PEG content. • Redox mechanism of luminescence quenching was proved via conductivity, DLS, and UV-visible absorbance measurements.

  3. Degradation of di-2-ethylhexyl phthalate in aqueous solution by advanced oxidation process

    Directory of Open Access Journals (Sweden)

    Maryam Zarean

    2015-01-01

    Conclusion: It could be found that the UV/O3 process is a method for DEHP degradation in aqueous solution and may be recommended as a supplement with other processes for treatment of solutions containing low DEHP concentrations.

  4. Process for disposal of aqueous solutions containing radioactive isotopes

    Science.gov (United States)

    Colombo, Peter; Neilson, Jr., Robert M.; Becker, Walter W.

    1979-01-01

    A process for disposing of radioactive aqueous waste solutions whereby the waste solution is utilized as the water of hydration to hydrate densified powdered portland cement in a leakproof container; said waste solution being dispersed without mechanical inter-mixing in situ in said bulk cement, thereafter the hydrated cement body is impregnated with a mixture of a monomer and polymerization catalyst to form polymer throughout the cement body. The entire process being carried out while maintaining the temperature of the components during the process at a temperature below 99.degree. C. The container containing the solid polymer-impregnated body is thereafter stored at a radioactive waste storage dump such as an underground storage dump.

  5. Process for disposal of aqueous solutions containing radioactive isotopes

    International Nuclear Information System (INIS)

    Colombo, P.; Neilson, R.M. Jr.; Becker, W.W.

    1979-01-01

    A process for disposing of radioactive aqueous waste solutions whereby the waste solution is utilized as the water of hydration to hydrate densified powdered portland cement in a leakproof container; said waste solution being dispersed without mechanical inter-mixing in situ in said bulk cement, thereafter the hydrated cement body is impregnated with a mixture of a monomer and polymerization catalyst to form polymer throughout the cement body. The entire process being carried out while maintaining the temperature of the components during the process at a temperature below 99 0 C. The container containing the solid polymer-impregnated body is thereafter stored at a radioactive waste storage dump such as an underground storage dump

  6. Kinetic Control of Aqueous Hydrolysis: Modulating Structure/Property Relationships in Inorganic Crystals

    Science.gov (United States)

    Neilson, James R.

    2011-12-01

    A grand challenge in materials science and chemistry revolves around the preparation of materials with desired properties by controlling structure on multiple length scales. Biology approaches this challenge by evolving tactics to transform soluble precursors into materials and composites with macro-scale and atomic precision. Studies of biomineralization in siliceous sponges led to the discovery of slow, catalytic hydrolysis of molecular precursors in the biogenesis of silica skeletal elements with well defined micro- and nano-scale architectures. However, the role of aqueous hydrolysis in the limit of kinetic control is not well understood; this allows us to form a central hypothesis: that the kinetics of hydrolysis modulate the structures of materials and their properties. As a model system, the diffusion of a simple hydrolytic catalyst (such as ammonia) across an air-water interface into a metal salt solution reproduces some aspects of the chemistry found in biomineralization, namely kinetic and vectorial control. Variation of the catalyst concentration modulates the hydrolysis rate, and thus alters the resulting structure of the inorganic crystals. Using aqueous solutions of cobalt(II) chloride, each product (cobalt hydroxide chloride) forms with a unique composition, despite being prepared from identical mother liquors. Synchrotron X-ray total scattering methods are needed to locate the atomic positions in the material, which are not aptly described by a traditional crystallographic unit cell due to structural disorder. Detailed definition of the structure confirms that the hydrolysis conditions systematically modulate the arrangement of atoms in the lattice. This tightly coupled control of crystal formation and knowledge of local and average structures of these materials provides insight into the unusual magnetic properties of these cobalt hydroxides. The compounds studied show significant and open magnetization loops with little variation with composition

  7. Radiolytic effect on the chemical state of iodine in aqueous solution

    International Nuclear Information System (INIS)

    Shiraishi, H.; Kimiya, T.; Ohmae, M.; Ishigure, K.

    1988-01-01

    The oxidation state of iodine dissolved in an aqueous solution is easily changed in the presence of radiation field. Hence, it is essential to take the radiolytic effect into account when one is to estimate chemical forms of iodine after being released into the containment under an LOCA condition. This paper summarizes results of γ-radiolysis experiments on aqueous solutions containing iodine species, which have been carried out to extend the previously reported study on the same system. Variation in iodine product distribution with time has been examined as before, utilizing a flow system under irradiation. Attention has been paid to the effect of oxygen, to that of an initial oxidation state of iodine, and to the influence of temperature. Some kinetic analysis on the system was also undertaken

  8. Gamma radiolysis of alkaline aqueous solutions of neptunium and plutonium ions

    International Nuclear Information System (INIS)

    Pikaev, A.K.; Gogolev, A.V.; Shilov, V.P.

    1998-01-01

    Full text: The paper is a brief review of data obtained by the authors from the study on redox reactions of neptunium and plutonium ions upon γ radiolysis of their aerated alkaline aqueous solutions. It includes the information on radiolytic reduction of Np(V), Np(VI) and Pu(VI) ions under various experimental conditions. It was found that the values of Np(VI) and Pu(VI) reduction yields do not depend on alkali concentration. The values considerably increase in the presence of some organic compounds (EDTA and formate were investigated). The formation of the Np(V) peroxo complex was observed in the γ radiolysis of alkaline aqueous solutions of Np(VI) and Np(V) in the presence of nitrate. The mechanism of radiolytic redox reactions of the ions is discussed in some detail

  9. Oligonucleotides as probes for studying polymerization reactions in dilute aqueous solution

    Science.gov (United States)

    Kolb, V.; Orgel, L. E.; Miller, S. L. (Principal Investigator)

    1994-01-01

    We have prepared a [32P]-labled oligonucleotide probe carrying a free primary amine at its 3'-terminus. This probe is used to initiate polymerization of aziridine (ethyleneimine) in aqueous solution. The nature of the oligomeric products and the kinetics of their formation are then monitored by gel electrophoresis. Our results are generally consistent with those obtained using conventional techniques. We have also investigated the effect of polyanionic templates on the rate of oligomerization of aziridine. We find that water-soluble polyanions generally accelerate the polymerization. The sodium salt of polymethacrylic acid is the most effective of the templates that we studied. The methods introduced in this paper should be applicable to a variety of polymerization reactions in aqueous solution. They should greatly simplify the screening of potentially prebiotic polymerization reactions.

  10. Viscosity and density tables of sodium chloride solutions

    Energy Technology Data Exchange (ETDEWEB)

    Fair, J.A.; Ozbek, H. (comps.)

    1977-04-01

    A file is presented containing tabulated data extracted from the scientific literature on the density and viscosity of aqueous sodium chloride solutions. Also included is a bibliography of the properties of aqueous sodium chloride solutions. (MHR)

  11. Enthalpic characteristics of interactions occurring between an ascorbic acid and some saccharides in aqueous solutions

    International Nuclear Information System (INIS)

    Terekhova, Irina V.; Kulikov, Oleg V.; Titova, Elena S.

    2004-01-01

    The enthalpies of solution of mono- and disaccharides were measured in water and aqueous ascorbic acid solutions at 298.15 K using a calorimeter of solution. Enthalpies of transfer of saccharides from water to aqueous ascorbic acid solutions were derived, and enthalpic coefficients of pair interaction h xy were calculated according to MacMillan-Mayer theory. Interactions of ascorbic acid with D-fructose and sucrose are energetically favorable and characterized by negative h xy coefficients while h xy for the interactions occurring between ascorbic acid and α-D glucose, D-galactose and maltose are positive. The obtained results are interpreted in terms of the influence of structure and solvation of solutes on the thermodynamic parameters of their interaction in solutions

  12. Investigation on Minimum Film Boiling Point of Highly Heated Vertical Metal Rod in Aqueous Surfactant Solution

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chi Young; Kim, Jae Han [Pukyong Nat’l Univ., Busan (Korea, Republic of)

    2017-09-15

    In this study, experiments were conducted on the MFB(minimum film boiling) point of highly heated vertical metal rod quenched in aqueous surfactant solution at various temperature conditions. The aqueous Triton X-100 solution(100 wppm) and pure water were used as the liquid pool. Their temperatures ranged from 77 °C to 100 °C. A stainless steel vertical rod of initial center temperature of 500 °C was used as a test specimen. In both liquid pools, as the liquid temperature decreased, the time to reach the MFB point decreased with a parallel increase in the temperature and heat flux of the MFB point. However, over the whole present temperature range, in the aqueous Triton X-100 solution, the time to reach the MFB point was longer, while the temperature and heat flux of the MFB point were reduced when compared with pure water. Based on the present experimental data, this study proposed the empirical correlations to predict the MFB temperature of a high temperature vertical metal rod in pure water and in aqueous Triton X-100 solution.

  13. Rapid structural analysis of nanomaterials in aqueous solutions

    Science.gov (United States)

    Ryuzaki, Sou; Tsutsui, Makusu; He, Yuhui; Yokota, Kazumichi; Arima, Akihide; Morikawa, Takanori; Taniguchi, Masateru; Kawai, Tomoji

    2017-04-01

    Rapid structural analysis of nanoscale matter in a liquid environment represents innovative technologies that reveal the identities and functions of biologically important molecules. However, there is currently no method with high spatio-temporal resolution that can scan individual particles in solutions to gain structural information. Here we report the development of a nanopore platform realizing quantitative structural analysis for suspended nanomaterials in solutions with a high z-axis and xy-plane spatial resolution of 35.8 ± 1.1 and 12 nm, respectively. We used a low thickness-to-diameter aspect ratio pore architecture for achieving cross sectional areas of analyte (i.e. tomograms). Combining this with multiphysics simulation methods to translate ionic current data into tomograms, we demonstrated rapid structural analysis of single polystyrene (Pst) beads and single dumbbell-like Pst beads in aqueous solutions.

  14. Ion clustering in aqueous salt solutions near the liquid/vapor interface

    Directory of Open Access Journals (Sweden)

    J.D. Smith

    2016-03-01

    Full Text Available Molecular dynamics simulations of aqueous NaCl, KCl, NaI, and KI solutions are used to study the effects of salts on the properties of the liquid/vapor interface. The simulations use the models which include both charge transfer and polarization effects. Pairing and the formation of larger ion clusters occurs both in the bulk and surface region, with a decreased tendency to form larger clusters near the interface. An analysis of the roughness of the surface reveals that the chloride salts, which have less tendency to be near the surface, have a roughness that is less than pure water, while the iodide salts, which have a greater surface affinity, have a larger roughness. This suggests that ions away from the surface and ions near the surface affect the interface in opposite ways.

  15. Molecular dynamics investigation of carbon nanotube junctions in non-aqueous solutions

    KAUST Repository

    Gkionis, Konstantinos

    2014-07-23

    The properties of liquids in a confined environment are known to differ from those in the bulk. Extending this knowledge to geometries defined by two metallic layers in contact with the ends of a carbon nanotube is important for describing a large class of nanodevices that operate in non-aqueous environments. Here we report a series of classical molecular dynamics simulations for gold-electrode junctions in acetone, cyclohexane and N,N-dimethylformamide solutions and analyze the structure and the dynamics of the solvents in different regions of the nanojunction. The presence of the nanotube has little effect on the ordering of the solvents along its axis, while in the transversal direction deviations are observed. Importantly, the orientational dynamics of the solvents at the electrode-nanotube interface differ dramatically from that found when only the electrodes are present.

  16. Pulse Radiolysis of Adrenaline in Acid Aqueous Solutions

    DEFF Research Database (Denmark)

    Gohn, M.; Getoff, N.; Bjergbakke, Erling

    1976-01-01

    Pulse radiolysis of adrenaline in acid aqueous solutions (pH 1–3) was carried out. The rate constants for the reactions of adrenaline with H and OH were determined: k(H + adr.) = (0·9±0·1) × 109 dm3 mol−1s−1; k(OH + adr.) = (1·65±0·15) × 1010 dm3 mol−1s−1. The H-adduct of adrenaline has two λmax...

  17. Tyrosine-sensitized photodimerization of thymine in aqueous solution

    International Nuclear Information System (INIS)

    Kaneko, M.; Matsuyama, A.; Nagata, C.

    1978-01-01

    Photodimerization of thymine in aqueous solution in the presence of tyrosine was studied with monochromatic UV irradiation. The total dimer formation was sensitized in the presence of tyrosine. The action spectrum of sensitized total dimer formation has a peak near 280 nm corresponding to the absorption maximum of tyrosine. Triplet quenchers reduced the sensitization substantially. It seems probable that tyrosine-sensitized photodimerization of thymine occurred via triplet-triplet energy transfer from tyrosine to thymine. (author)

  18. Photoproduction of hydrogen peroxide in aqueous solution from model compounds for chromophoric dissolved organic matter (CDOM)

    International Nuclear Information System (INIS)

    Clark, Catherine D.; Bruyn, Warren de; Jones, Joshua G.

    2014-01-01

    Highlights: • CDOM produces hydrogen peroxide in sunlit surface waters. • Quinone moieties have been proposed as the photo-active chromophore in CDOM. • Hydrogen peroxide is produced in irradiated aqueous quinone solutions. • Concentrations and production rates are comparable to humic and fulvic acids. • Optical properties post-irradiation were similar to CDOM. - Abstract: To explore whether quinone moieties are important in chromophoric dissolved organic matter (CDOM) photochemistry in natural waters, hydrogen peroxide (H 2 O 2 ) production and associated optical property changes were measured in aqueous solutions irradiated with a Xenon lamp for CDOM model compounds (dihydroquinone, benzoquinone, anthraquinone, napthoquinone, ubiquinone, humic acid HA, fulvic acid FA). All compounds produced H 2 O 2 with concentrations ranging from 15 to 500 μM. Production rates were higher for HA vs. FA (1.32 vs. 0.176 mM h −1 ); values ranged from 6.99 to 0.137 mM h −1 for quinones. Apparent quantum yields (Θ app ; measure of photochemical production efficiency) were higher for HA vs. FA (0.113 vs. 0.016) and ranged from 0.0018 to 0.083 for quinones. Dihydroquinone, the reduced form of benzoquinone, had a higher production rate and efficiency than its oxidized form. Post-irradiation, quinone compounds had absorption spectra similar to HA and FA and 3D-excitation–emission matrix fluorescence spectra (EEMs) with fluorescent peaks in regions associated with CDOM

  19. The biosorption of cadmium and lead ions from aqueous Solution ...

    African Journals Online (AJOL)

    The biosorption potentiality of Musa paradisiaca stalk at removing cadmium and lead ions from aqueous solution was investigated. The biosorption experiment was carried out as a function of contact time, initial pH, initial metal ion concentration and biosorbent dose. Adsorption equilibria were obtained from batch ...

  20. Heterogeneous primary nucleation of ice in water and aqueous solutions

    NARCIS (Netherlands)

    Thijssen, H.A.C.; Vorstman, M.A.G.; Roels, J.A.

    1968-01-01

    The effect of the volume of the liquid sample, the degree of turbulence in the liquid, and the rate of cooling upon the probability of nucleation has been studied for water and aqueous solutions. Nucleation rates were measured for droplets nearly instantaneously cooled to a predetermined

  1. Optimization of palm oil extraction from Decanter cake of small crude palm oil mill by aqueous surfactant solution using RSM

    Science.gov (United States)

    Ahmadi Pirshahid, Shewa; Arirob, Wallop; Punsuvon, Vittaya

    2018-04-01

    The use of hexane to extract vegetable oil from oilseeds or seed cake is of growing concern due to its environmental impact such as its smelling and toxicity. In our method, used Response Surface Methodology (RSM) was applied to study the optimum condition of decanter cake obtained from small crude palm oil with aqueous surfactant solution. For the first time, we provide an optimum condition of preliminary study with decanter cake extraction to obtain the maximum of oil yield. The result from preliminary was further used in RSM study by using Central Composite Design (CCD) that consisted of thirty experiments. The effect of four independent variables: the concentration of Sodium Dodecyl Sulfate (SDS) as surfactant, temperature, the ratio by weight to volume of cake to surfactant solution and the amount of sodium chloride (NaCl) on dependent variables are studied. Data were analyzed using Design-Expert 8 software. The results showed that the optimum condition of decanter cake extraction were 0.016M of SDS solution concentration, 73°C of extraction temperature, 1:10 (g:ml) of the ratio of decanter cake to SDS solution and 2% (w/w) of NaCl amount. This condition gave 77.05% (w/w) oil yield. The chemical properties of the extracted palm oil from this aqueous surfactant extraction are further investigated compared with the hexane extraction. The obtained result showed that all properties of both extractions were nearly the same.

  2. Efficient device for the benign removal of organic pollutants from aqueous solutions using modified mesoporous magnetite nanostructures

    Science.gov (United States)

    Vojoudi, H.; Badiei, A.; Amiri, A.; Banaei, A.; Ziarani, G. M.; Schenk-Joß, K.

    2018-02-01

    In this study, a home-made device comprising a column filled with magnetic mesoporous silica-coated nanostructures (MSCM-PA) as an adsorbent was constructed and used to remove organic pollutants from aqueous solutions. The MSCM-PA adsorbent was prepared and characterized using Fourier transform-infrared spectroscopy, ultraviolet-visible spectroscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive X-ray spectroscopy, vibrating sample magnetometry, Brunauer-Emmett-Teller, thermogravimetric analysis/differential thermal analysis, and powder X-ray diffraction techniques. The adsorption behavior of the MSCM-PA sorbent was studied based on the removal of Everzol blue dye from aqueous solutions. We investigated the effects of various parameters such as the solution pH, initial dye concentration, adsorbent dose, flow rate, and contact time on the adsorption of Everzol blue from aqueous solutions. The adsorption data were modeled using Langmuir and Freundlich isotherms, and a good fit was obtained with the Langmuir isotherm. The maximum Everzol blue adsorption capacity by MSCM-PA was 162 mg g-1. The results indicate that our device is capable of adsorbing anionic dyes from aqueous solutions.

  3. Chemical dosimetry by UV spectrophotometry of aqueous ascorbic acid solutions

    International Nuclear Information System (INIS)

    Alian, A.; El-Assay, N.B.; Abdel-Rehim, F.; Amin, N.E.; McLaughlin, W.L.; Roushdy, H.

    1984-01-01

    The decrease in the ultraviolet absorption of aqueous solutions of ascorbic acid brought about by large doses of gamma radiation has been investigated as a means of developing a new chemical dosimeter. Because of spontaneous ring opening under various conditions after dissolution in water, some additives were examined as possible stabilizers against such denaturing of aqueous ascorbic acid. At an ascorbic acid concentration of 10 -4 M, either 1 to 2% glycine or 0.2 M NaCl was found to be a good stabilizer. A mechanism of radiation chemistry has been proposed based on hydroxyl radical and hydroxyl adduct intermediates, leading to dehydroascorbic acid through the ascorbate complex. The optimum dosimeter solution covers an absorbed dose range approx. 50 to 350 Gy, when measured at 264 nm wavelength. The G-values for dehydroascorbic acid production were determined to be 2.94 +- 0.33 and 2.43 +- 0.11 (100 eV) -1 , with glycine and NaCl used respectively as stabilizers. (author)

  4. Effect of solvent composition on the limiting current of anodic dissolution of tungsten in aqueous-ethanol solutions of alkali

    International Nuclear Information System (INIS)

    Konoplyantseva, N.A.; L'vova, L.A.; Davydov, A.D.; AN SSSR, Moscow. Inst. Ehlektrokhimii)

    1987-01-01

    The effect of quantitative composition of solvent on tungsten anodic dissolution in aqueous-ethanol solutions of KOH is studied. It is shown that with an increase in ethanol content in aqueous-ethanol solutions of alkali the limiting current of tungsten anodic dissolution decreases. An increase in KOH concentration in certain limits (in ethanol solutions it is the range between 0.75 and 1.0 M KOH) results in the increase of the limiting current; with further increase in solution concentration the limiting current decreases, which can be related to the change of the limiting stage. An assumption is made that total reaction of tungsten anodic dissolution and the main reasons for the limiting current appearance do not change from aqueous to aqueous-ethanol and ethanol solutions of alkali

  5. Correlation and prediction of osmotic coefficient and water activity of aqueous electrolyte solutions by a two-ionic parameter model

    International Nuclear Information System (INIS)

    Pazuki, G.R.

    2005-01-01

    In this study, osmotic coefficients and water activities in aqueous solutions have been modeled using a new approach based on the Pitzer model. This model contains two physically significant ionic parameters regarding ionic solvation and the closest distance of approach between ions in a solution. The proposed model was evaluated by estimating the osmotic coefficients of nine electrolytes in aqueous solutions. The obtained results showed that the model is suitable for predicting the osmotic coefficients in aqueous electrolyte solutions. Using adjustable parameters, which have been calculated from regression between the experimental osmotic coefficient and the results of this model, the water activity coefficients of aqueous solutions were calculated. The average absolute relative deviations of the osmotic coefficients between the experimental data and the calculated results were in agreement

  6. Lactose and sucrose aqueous solutions for high-dose dosimetry with 10-MeV electron beam irradiation

    International Nuclear Information System (INIS)

    Amraei, R.; Kheirkhah, M.; Raisali, G.

    2012-01-01

    In the present study, dosimetric characterisation of aqueous solutions of lactose and sucrose was analysed by UV spectrometry following irradiation using 10-MeV electron beam at doses between 0.5 and 10.5 kGy. As a dosimetric index, absorbance is selected at 256 and 264 nm for lactose and sucrose aqueous solutions, respectively. The intensity of absorbance for irradiated solutions depends on the pre-irradiation concentration of lactose and sucrose. The post-irradiation stability of both solutions was investigated at room temperature for a measurement period of 22 d. (authors)

  7. Aqueous amine solution characterization for post-combustion CO_2 capture process

    International Nuclear Information System (INIS)

    El Hadri, Nabil; Quang, Dang Viet; Goetheer, Earl L.V.; Abu Zahra, Mohammad R.M.

    2017-01-01

    Highlights: • The CO_2 solubility of 30 aqueous amine solutions was measured at 30 wt% and 313.15 K. • The CO_2 loading of HMD is the highest, and that of TEA is the lowest. • 2DMAE, 3DMA1P, 1DMA2P, MDEA, TMPAD and 2EAE have a low heat of absorption with CO_2. • 2EAE can be used as an alternative to MEA in the CO_2 capture process. - Abstract: This article presents a thermodynamic and kinetic characterization of CO_2 absorption by 30 aqueous amine solutions. A solvent screening setup (S.S.S.) was used to find the CO_2 loading (α) for 30 different aqueous amine solutions (30 wt%) at a pressure of 1 bar with feed gas containing 15 vol% CO_2 and 85 vol% N_2 at 313.15 K to provide reliable absorber parameters. The structures of various amines (linear, non-linear, polyamines, sterically hindered, etc.) were tested and the S.S.S. results showed that hexamethylenediamine (HMD) has higher CO_2 loading at 1.35 moles of CO_2/mole of amine, and triethanolamine (TEA) has the lowest at 0.39 mole of CO_2/mole of amine. The heat of absorption indicates that MDEA has the lowest and HMD has the highest at −52.51 kJ/mole of CO_2 and −98.39 kJ/mole of CO_2, respectively. The combined data for the CO_2 loading and the absorption heat generated 6 amines that have good properties for the post-combustion CO_2 capture process in comparison with that of MEA. These amines are made up of one secondary amine (2-ethylaminoethanol, 2EAE) and 5 tertiary amines (N-methyldiethanolamine, MDEA, 1-dimethylamino-2-propanol, 1DMA2P, 2-dimethylaminoethanol, 2DMAE, 3-dimethylamino-1-propanol, 3DMA1P and N,N,N′,N′-tetramethyl-1,3-propanediamine, TMPDA). In comparison with the amine reference MEA (ΔH = −85.13 kJ/mole of CO_2 and α = 0.58 mole CO_2/mole of amine), the 6 amines have heats of absorption that are between −68.95 kJ/mole of CO_2 and −52.51 kJ/mole of CO_2, and their CO_2 loading is between 0.52 and 1.16 mole of CO_2/mole amine. The third important parameter, namely the

  8. Immobilization of lead and cadmium from aqueous solution and contaminated sediment using nano-hydroxyapatite

    International Nuclear Information System (INIS)

    Zhang Zizhong; Li Mengyan; Chen Wei; Zhu Shuzhen; Liu Nannan; Zhu Lingyan

    2010-01-01

    The effectiveness and mechanism of nano-hydroxyapatite particles (nHAp) in immobilizing Pb and Cd from aqueous solutions and contaminated sediment were investigated. The maximum sorption amount (Q max ) of Pb and Cd in aqueous solution was 1.17 and 0.57 mmol/g. The X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) surface and depth analysis indicated that dissolution-precipitation is the primary immobilization mechanism for Pb, while surface complexation and intraparticle diffusion account for Cd sequestration. Different amounts of nHAp (0-10% nHAp/dry weight) were added to the contaminated sediment. Sequential extraction showed that nHAp could effectively reduce the exchangeable fraction of Pb and Cd in the sediment and significantly reduce the concentration in porewater. The results in this study showed that nHAp can immobilize Pb and Cd in sediment effectively. - Nano-hydroxyapatite shows potential and advantages to immobilize lead and cadmium in aqueous solution and sediment.

  9. Probing ion-specific effects on aqueous acetate solutions: Ion pairing versus water structure modifications.

    Science.gov (United States)

    Petit, Tristan; Lange, Kathrin M; Conrad, Gerrit; Yamamoto, Kenji; Schwanke, Christoph; Hodeck, Kai F; Dantz, Marcus; Brandenburg, Tim; Suljoti, Edlira; Aziz, Emad F

    2014-05-01

    The effect of monovalent cations (Li(+), K(+), NH4 (+), Na(+)) on the water structure in aqueous chloride and acetate solutions was characterized by oxygen K-edge X-ray absorption spectroscopy (XAS), X-ray emission spectroscopy, and resonant inelastic X-ray scattering (RIXS) of a liquid microjet. We show ion- and counterion dependent effects on the emission spectra of the oxygen K-edge, which we attribute to modifications of the hydrogen bond network of water. For acetates, ion pairing with carboxylates was also probed selectively by XAS and RIXS. We correlate our experimental results to speciation data and to the salting-out properties of the cations.

  10. Probing ion-specific effects on aqueous acetate solutions: Ion pairing versus water structure modifications

    Directory of Open Access Journals (Sweden)

    Tristan Petit

    2014-05-01

    Full Text Available The effect of monovalent cations (Li+, K+, NH4+, Na+ on the water structure in aqueous chloride and acetate solutions was characterized by oxygen K-edge X-ray absorption spectroscopy (XAS, X-ray emission spectroscopy, and resonant inelastic X-ray scattering (RIXS of a liquid microjet. We show ion- and counterion dependent effects on the emission spectra of the oxygen K-edge, which we attribute to modifications of the hydrogen bond network of water. For acetates, ion pairing with carboxylates was also probed selectively by XAS and RIXS. We correlate our experimental results to speciation data and to the salting-out properties of the cations.

  11. Partially Hydrolyzed Poly(n-propyl-2-oxazoline): Synthesis, Aqueous Solution Properties, and Preparation of Gene Delivery Systems.

    Science.gov (United States)

    Mees, Maarten; Haladjova, Emi; Momekova, Denitsa; Momekov, Georgi; Shestakova, Pavletta S; Tsvetanov, Christo B; Hoogenboom, Richard; Rangelov, Stanislav

    2016-11-14

    Random copolymers of n-propyl-2-oxazoline and ethylenimine (PPrOx-PEI) were prepared by partial acidic hydrolysis of poly(n-propyl-2-oxazoline) (PPrOx). Dynamic and electrophoretic light scattering and diffusion-ordered NMR spectroscopy were utilized to investigate aqueous solution properties of the copolymers. Above a specific cloud point temperature, well-defined nanoparticles were formed. The latter consisted of a core composed predominantly of PPrOx and a thin positively charged shell from PEI moieties that mediated formation of polyplexes with DNA. The polyplexes were prepared at 65 °C at varying N/P (amine-to-phosphate groups) ratios. They underwent structural changes upon temperature variations 65-25-37 °C depending on N/P. At N/P < 2, the polyplex particles underwent minor changes because of formation of a surface layer of DNA that acted as a barrier and prevented swelling and disintegration of the initial particles. Dramatic rearrangements at N/P ≥ 2 resulting in large swollen microgel particles were overcome by coating of the polyplex particles with a cross-linked polymeric shell. The shell retained the colloidal stability and preserved the physicochemical parameters of the initial polyplex particles while it reduced the high surface potential values. Progressive loss of cytotoxicity upon complexation with DNA and coating of polyplex particles was displayed.

  12. Volumetric properties for glycine and L-serine in aqueous solutions of 1-Ethyl-3-methylimidazolium hydrogen sulfate ([Emim][HSO4]) at T = (293.15–313.15) K and ambient pressure

    International Nuclear Information System (INIS)

    Rafiee, Hamid Reza; Frouzesh, Farshid

    2016-01-01

    Highlights: • Ternary systems (amino acid + ionic liquid + H 2 O) are considered. • Volumetric properties including density, V φ , ΔV φ 0 and E φ 0 are determined. • Glycine and L-serine were amino acids and [Emim][HSO 4 ] was IL studied. • V φ values for amino acids increased with both concentration of amino acids and temperature. • Both studied amino acids act as structure maker in ternary systems. - Abstract: By using the volumetric properties, the solute–solvent interactions are studied in the ternary (glycine + 1-Ethyl-3-methylimidazolium hydrogen sulfate [Emim][HSO 4 ] + water) and (L-serine + 1-Ethyl-3-methylimidazolium hydrogen sulfate [Emim][HSO 4 ] + water) systems. For this purpose, the apparent molar volumes, V φ , are calculated from the experimental density data. To obtain limiting apparent molar volumes V φ 0 , the apparent molar volume values are fitted to the Redlich-Mayer type equation. Then the limiting apparent molar volumes of transfer, ΔV φ 0 , for studied amino acids from water to aqueous solutions of ionic liquid (IL) are calculated. The results showed that the ΔV φ 0 values are negative for both ternary systems at all temperatures. The limiting apparent molar expansibility E φ 0 values have been obtained from the first derivative of limiting apparent molar volumes with respect to temperature. The values of second derivative of limiting apparent molar volumes respect to temperature show the structure making or breaking ability of glycine and L-serine in studied IL aqueous solutions. The results indicated that glycine and L-serine act as structure maker in studied solutions. McMillan–Mayer theory is used for evaluating the interaction parameters. Also the hydration number, n H , for both amino acids in ternary solutions has been reported.

  13. Two components of Na emission in sonoluminescence spectrum from surfactant aqueous solutions.

    Science.gov (United States)

    Hayashi, Yuichi; Choi, Pak-Kon

    2015-03-01

    Sonoluminescence from sodium dodecyl sulfate (SDS) aqueous solutions exhibits Na emission. The spectrum of Na emission was measured as a function of sonication time for a total of 30 min at an ultrasonic frequency of 148 kHz. The spectral line profiles changed with the sonication time, suggesting that the Na emission consists of two components: broadened lines, which are shifted from the original D lines, and unshifted narrow lines. The intensity of the unshifted narrow lines decreased at a greater rate than that of the broadened lines with increasing sonication time. This effect was enhanced at a higher acoustic power. The shifted broadened lines remained after sonication for 30 min. We propose that these quenching effects are caused by the accumulation of gases decomposed from SDS molecules inside bubbles. The CO₂ gas dependence of Na emission in NaCl aqueous solutions showed a similar change in the line profiles to that in SDS aqueous solutions, which supported this proposition. The unshifted narrow lines are easily affected by foreign gases. The results suggest that the two components originate from different environments around the emitting species, although both of them originate from the gas phase inside bubbles. The generation mechanisms of the two components are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Removal of trace Cd2+ from aqueous solution by foam fractionation.

    Science.gov (United States)

    Lu, Jian; Li, Ying; Zhang, Sen; Sun, Yange

    2015-04-09

    In recent years, aqueous foam was known as an efficient technique with high potential on being used to remove heavy metal ions from the polluted water, not only because of the low cost, simple operation, but also ascribed to the high removal efficiency of trace heavy metal ions and would not cause secondary pollution to the environment. In this paper, the removal of Cd(2+) from aqueous solution by aqueous foam stabilized by a kind of novel anionic-nonionic surfactant sodium trideceth-4 carboxylate (AEC) was investigated. The effect of conditions such as surfactant/metal ions molar ratio, surfactant concentration on the removal efficiency was studied. In large concentration range of surfactant, the removal rate was higher than 90%, and could reach up to 99.8% under the optimum conditions. The Zeta potential of gas bubbles in the AEC solutions was determined to verify the combination between the negative charged group heads of surfactant molecules and heavy metal ions, and isothermal titration calorimeter (ITC) determination was utilized to demonstrate the interaction, which helped to understand the mechanisms more clearly. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Bioremediation of zirconium from aqueous solution by coriolus versicolor: process optimization

    International Nuclear Information System (INIS)

    Amin, M.; Bhatti, H. N.; Sadaf, S.

    2013-01-01

    In the present study the potential of live mycelia of Coriolus versicolor was explored for the removal of zirconium from simulated aqueous solution. Optimum experimental parameters for the bioremediation of zirconium using C. versicolor biomass have been investigated by studying the effect of mycelia dose, concentration of zirconium, contact time and temperature. The isothermal studies indicated that the ongoing bioremediation process was exothermic in nature and obeyed Langmuir adsorption isotherm model. The Gibbs free energy (ΔG), entropy (ΔS) and enthalpy (ΔH) of bioremediation were also determined. The result showed that bioremediation of zirconium by live C. versicolor was feasible and spontaneous at room temperature. The equilibrium data verified the involvement of chemisorption during the bioremediation. The kinetic data indicated the operation of pseudo-second order process during the biosorption of zirconium from aqueous solution. Maximum bioremediation capacity (110.75 mg/g) of C. versicolor was observed under optimum operational conditions: pH 4.5, biomass dose 0.05 mg/100 mL, contact time 6 h and temperature 30 degree C. The results showed that C. versicolor could be used for bioremediation of heavy metal ions from aqueous systems. (author)

  16. Preparation of novel polysulfone capsules containing zirconium phosphate and their properties for Pb{sup 2+} removal from aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Ma Xiaojie [College of Chemistry and Chemical Engineering, State Key Laboratory of Applied Organic Chemistry, College of Resources and Environment, Institute of Biochemical Engineering and Environmental Technology, Lanzhou University, Lanzhou 730000 (China); Li Yanfeng, E-mail: liyf@lzu.edu.cn [College of Chemistry and Chemical Engineering, State Key Laboratory of Applied Organic Chemistry, College of Resources and Environment, Institute of Biochemical Engineering and Environmental Technology, Lanzhou University, Lanzhou 730000 (China); Li Xiaoli; Yang Liuqing [College of Chemistry and Chemical Engineering, State Key Laboratory of Applied Organic Chemistry, College of Resources and Environment, Institute of Biochemical Engineering and Environmental Technology, Lanzhou University, Lanzhou 730000 (China); Wang Xueyan [Yantai Professional School of Automobile Engineering, Yantai 265500 (China)

    2011-04-15

    Zirconium phosphate (ZrP) was immobilized by microencapsulation process of polysulfone (PSF) to form the polysulfone capsules containing ZrP (PSF-ZrP capsules) successfully by using phase inversion precipitation technique, and the PSF-ZrP was employed as capsules adsorbents to remove Pb{sup 2+} presented in aqueous solution. The result shows that an encapsulation capacity of 50% (mass ratio, PSF: ZrP = 1:1) should be the optimal proportion of ZrP encapsulated with PSF. The characterization of the macroscopical and microcosmic physical properties of the resulting PSF-ZrP capsules was carried out by the DTA-TG, XRD, BET and SEM. Meanwhile, the adsorption properties of the PSF-ZrP capsules for Pb{sup 2+} were investigated by batch methods. It was found that the adsorption of the PSF-ZrP capsules for Pb{sup 2+} would be pH dependent due to the ion-exchange mechanism, and the uptake of Pb{sup 2+} was slightly influenced with the concentration of coexisting cations (Na{sup +}, K{sup +}) in a low range. Furthermore, the calculated thermodynamics parameters exhibit that the nature of the adsorption process is spontaneous and exothermic. After six times of adsorption-regeneration cycles, no significant loss of adsorption capacity was observed, indicating the good stability of the PSF-ZrP capsules. Consequently, the PSF-ZrP capsules in this work can provide a potential application for treatment process of Pb{sup 2+}-containing wastewater.

  17. Adsorption of methylene blue from aqueous solution on the surface ...

    African Journals Online (AJOL)

    Adsorption of dye methylene blue from aqueous solution on the surface of sheep wool and cotton fibers was accomplished under the optimize conditions of temperature, concentration, pH, stay time duration and quantity of adsorbent. Spectrometric technique was used for the measurements of concentration of dye before ...

  18. Solvation consequences of polymer PVP with biological buffers MES, MOPS, and MOPSO in aqueous solutions

    International Nuclear Information System (INIS)

    Gupta, Bhupender S.; Chen, Bo-Ren; Lee, Ming-Jer

    2015-01-01

    Highlights: • Densities and viscosities data for aqueous solutions with PVP and/or buffer. • The studied buffers include MES, MOPS, and MOPSO. • DFT was used to estimate the binding energies of the (PVP + buffer) complexes. • The viscosity data were correlated with the Jones–Dole equation. • The investigated buffers behave as Kosmotropies. - Abstract: Densities and viscosities were measured for the aqueous buffer (MES, MOPS, or MOPSO) solutions containing different concentrations of polyvinylpyrrolidone (PVP) (5, 10, 15, 20 and 30) mass% at temperatures from (298.15 to 318.15) K under atmospheric pressure. The DFT calculations were also performed and the binding energies of the possible (PVP + buffer) complexes were obtained. The experimental and computational results reveal the interactions of the PVP with the constituent compounds in the aqueous buffer solutions. Additionally we have explored the solvation behavior of the buffers by measuring the densities and the viscosities data of the aqueous buffer solutions from (0.0 to 1.0) mol · kg"−"1 at temperatures from (298.15 to 318.15) K. The viscosity results were correlated with the Jones–Dole equation. The correlated results confirmed that all the investigated buffers behave as Kosmotropes (structure makers).

  19. (p,Vm,T,x) measurements for aqueous LiNO3 solutions

    International Nuclear Information System (INIS)

    Abdulagatov, I.M.; Azizov, N.D.

    2004-01-01

    (p,V m ,T,x) properties of four aqueous LiNO 3 solutions (0.181, 0.526, 0.963, and 1.728) mol · kg -1 H 2 O were measured in the liquid phase with a constant-volume piezometer immersed in a precision liquid thermostat. Measurements were made for 10 isotherms between (298 and 573) K. The range of pressure was from (2 to 40) MPa. The total uncertainty of density, pressure, temperature, and concentration measurements were estimated to be less than 0.06 %, 0.05 %, 10 mK, and 0.014 %, respectively. The values of saturated density were determined by extrapolating experimental (p,ρ) data to the vapor-pressure at fixed temperature and composition using an interpolating equation. A polynomial type of equation of state for specific volume was obtained as a function of temperature, pressure, and composition by a least-squares method from the experimental data. The average absolute deviation (AAD) between measured and calculated values from this polynomial equation for density was 0.02 %. Measured values of solution density were compared with values calculated from Pitzer's ion-interaction equation. The agreement is within (0.2 to 0.4) % depending of concentration range

  20. NMR studies of proton exchange kinetics in aqueous formaldehyde solutions.

    Science.gov (United States)

    Rivlin, Michal; Eliav, Uzi; Navon, Gil

    2014-05-01

    Aqueous solutions of formaldehyde, formalin, are commonly used for tissue fixation and preservation. Treatment with formalin is known to shorten the tissue transverse relaxation time T2. Part of this shortening is due to the effect of formalin on the water T2. In the present work we show that the shortening of water T2 is a result of proton exchange between water and the major constituent of aqueous solutions of formaldehyde, methylene glycol. We report the observation of the signal of the hydroxyl protons of methylene glycol at 2ppm to high frequency of the water signal that can be seen at low temperatures and at pH range of 6.0±1.5 and, at conditions where it cannot be observed by the single pulse experiment, it can be detected indirectly through the water signal by the chemical exchange saturation transfer (CEST) experiment. The above finding made it possible to obtain the exchange rate between the hydroxyl protons of the methylene glycol and water in aqueous formaldehyde solutions, either using the dispersion of the spin-lattice relaxation rate in the rotating frame (1/T1ρ) or, at the slow exchange regime, from the line width hydroxyl protons of methylene glycol. The exchange rate was ∼10(4)s(-1) at pH 7.4 and 37°C, the activation energy, 50.2kJ/mol and its pH dependence at 1.1°C was fitted to: k (s(-1))=520+6.5×10(7)[H(+)]+3.0×10(9)[OH(-)]. Copyright © 2014. Published by Elsevier Inc.

  1. The radiation-induced degradation of a diazo dye in aqueous solution Pt. 2

    International Nuclear Information System (INIS)

    El-Assy, N.B.; Abdel-Rehim, F.; Abdel-Gawad, A.S.; Abdel-Fattah, A.A.

    1992-01-01

    The effect of γ-radiation on the color intensity of aerated, deaerated and oxygenated aqueous solutions of a diazo dye (Helion Red 8B) has been investigated. The decoloration yields of Helion Red 8B neutral aqueous solution, G(-Dye), for the nitrogen-, oxygen- and aerated-saturated solutions were found to be 0.77, 0.46 and 0.36 in the respective early stage. The rate constant for the reaction of the OH radical with the HR8B dye, obtained from competition kinetics using ethanol, was found to be 1.3*10 10 M -1 *s -1 . In aerated solutions (pH 3), the G(-Dye) decreased markedly upon the addition of a very small amount of ethanol. Suggestions are made for possible use of the dye as a radiation dosimeter in the dose range of 0.1 to 2 kGy. (author) 16 refs.; 8 figs.; 1 tab

  2. Investigation of the removal of chromium (VI by Nanocomposites Chitosan-tragacanth solution from aqueous solution

    Directory of Open Access Journals (Sweden)

    Adel Almasi Nahnaji

    2016-03-01

    Full Text Available Background: The aim of this study was to investigate the removal of chromium (VI by Nanocomposites Chitosan-tragacanth solution from aqueous solution. Methods: In this study, chitosan-tragacanth nanocomposites were synthesized and analyzed by electron microscopy (SEM, (TEM and Fourier transform spectroscopy (FT-IR for the size and shape of the surface. The nano-composite of chitosan-tragacanth, for the adsorption of chromium (VI in aqueous solution was used as adsorbent. Results: The optimum conditions with multiple experiments to enhance the absorption were evaluated. The highest absorption of Cr (VI was occurred in the adsorbent dosage of 0.2 g, 8 ppm concentration of chromium ions, the pH=6 and also retention time of 50 min; in 298 ˚K temperature. After determining optimal conditions of adsorption, isotherms equations and study and thermodynamic parameters were applied. Adsorption process of chromium (VI on nano-composite chitosan - Tragacanth was conformed with Temkin isotherm. Conclusion: The thermodynamic parameters such as standard Gibbs free energy changes, changes in enthalpy and entropy changes in the standard showed that the adsorption process of Cr (VI is spontaneous and heating, and kinetics studies of models Lagergren, Ho , Alovich and intraparticle is used, the results show that the adsorption kinetics follows the pseudo-second order.

  3. Electrical Conductivity of Gamma Irradiated Aqueous Urea Solution and its Application for Determination of Absorbed Radiation Dose; Sife-Eldeen Dosimeter

    International Nuclear Information System (INIS)

    Sife- Eldeen, Kh.A.

    2008-01-01

    In This Study, the radiation induced electrical conductivity (RIC) of aqueous urea solutions was investigated after gamma radiolysis. It was found that the RIC depends on preirradiation urea concentration, absorbed radiation dose and storage time. At the same absorbed dose, RIC increases as preirradiation urea concentration increases. The RIC change of aqueous urea solutions reaches a maximum value at 3.5 M aqueous urea solutions. RIC of 0.133 and 3.5 M aqueous urea solutions as a function of dose, have been investigated in the range between 2.18 and 119.4 kGy. RIC of the 0.133 and 3.5 M aqueous urea solutions increased linearly with increasing dose (R 2 =0.9963, 0.9972 respectively). The calibration factors was found to be 2.1448 and 9.53 μS/kGy for sets with 0.133 and 3.5 M urea respectively .The coefficient of variation CV %, associated with RIC measurement of 3.5 M aqueous urea solution as a function of absorbed radiation dose was found to be 1.8025% and the uncertainty was found to be 3.6 % and 5.4 % for 95 % and 99 % confidence levels, respectively. The effective atomic number of 3.5 M aqueous urea solutions is 6.58, which indicates tissue equivalency of this system. The RIC values of 3.5 M aqueous urea solutions were found to be relatively stable over storage period of three weeks at 0 degree C. Accordingly, this system could be considered as a promising radiation-sensitive material for dosimetry of gamma rays in both technical and research fields

  4. Plasma induced degradation of benzidine in aqueous solution

    International Nuclear Information System (INIS)

    Gao Jinzhang; Gai Ke; Yang Wu; Dong Yanjie

    2003-01-01

    The degradation of benzidine in aqueous solution by the low temperature plasma was examined. The results showed that the concentration of medium and the value of pH have an appreciable effect on the degradation of benzidine. What is more important is that iron ions acting as a catalyst play an important role in this reaction. For exploring the degradation mechanism of benzidine, some of the intermediate products were recorded by HPLC (high performance liquid chromatography)

  5. Heterogeneity of activated carbons in adsorption of aniline from aqueous solutions

    Science.gov (United States)

    Podkościelny, P.; László, K.

    2007-08-01

    The heterogeneity of activated carbons (ACs) prepared from different precursors is investigated on the basis of adsorption isotherms of aniline from dilute aqueous solutions at various pH values. The APET carbon prepared from polyethyleneterephthalate (PET), as well as, commercial ACP carbon prepared from peat were used. Besides, to investigate the influence of carbon surface chemistry, the adsorption was studied on modified carbons based on ACP carbon. Its various oxygen surface groups were changed by both nitric acid and thermal treatments. The Dubinin-Astakhov (DA) equation and Langmuir-Freundlich (LF) one have been used to model the phenomenon of aniline adsorption from aqueous solutions on heterogeneous carbon surfaces. Adsorption-energy distribution (AED) functions have been calculated by using an algorithm based on a regularization method. Analysis of these functions for activated carbons studied provides important comparative information about their surface heterogeneity.

  6. Cobalt separation present in aqueous solution using shell tamarind as bio sorbent; Separacion de cobalto presente en solucion acuosa utilizando cascara de tamarindo como biosorbente

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez L, J.

    2014-07-01

    In this work a new carbonaceous material is presented with improved adsorption properties obtained by a heart treatment about 5 min from the shell tamarind. It was found that the samples obtained carbonaceous adsorbents are effective in removing Co{sup 2+} (41 mg / g) ions in aqueous solutions. These samples were prepared from tamarind shell, urea, ammonium nitrate and water. The solution was subjected to a combustion process at different temperatures. Carbonaceous samples prepared in this manner were characterized by X-ray diffraction, infrared spectroscopy, scanning electron microscopy (Sem) and surface area measurements by Physisorption of N{sub 2}. Changes in structure, morphology and texture were studied. The results show that this material is of great importance to the applications of adsorption of metal ions. The measurements of specific surface area (Bet) were 2.35 to 203.76 m{sup 2} g{sup -1} with pore diameters between 2.31 and 15.63 nm, indicating that the samples obtained are predominantly meso porous. The combustion process of the solution proved to be advantageous to improve the textural properties of the tamarind shell. The obtained carbonaceous material plays an important role in adsorption to remove cobalt in aqueous solutions. (Author)

  7. [Effect of 60Co gamma-irradiation on dilute aqueous solutions of surfactants].

    Science.gov (United States)

    Sawai, T; Shimokowa, T; Miki, Y; Oseko, K; Sawai, T

    1978-01-01

    Present work deals with the effects of gamma irradiation from 60Co gamma-ray source upon aqueous solutions of three kinds of surfactants. When dilute aqueous solutions of sodium dodecyl sulfate (SDS, anionic), cethyl trimethyl ammonium chloride (CTAC, cationic), and polyoxyethylene lauryl ether (POE, non-ionic) were irradiated with gamma-rays at a room remperature, the residual concentration, products, surface tension, and forming power were examined by colorimetric method, IR spectrophotometric method, gaschromatography, Ross-Miles method, and Traube's stalagnometer etc.. These surfactants were decomposed by the irradiation and thus the surface tension increased and the forming power, on the contrary, decreased with dose. Radiation chemical yields (G-value) of the degradation were about 1 for the solutions of SDS and CTAC, and about 0.3 for the POE solution. From the experimental results, it was found that following chemical reactions seem to occur followed by the radiolysis of water; a) bond cleavage of ester for SDS, of CN for CTAC, and of oxyethylene for POE, b) hydrogen abstraction from the surfactants, c) production of CO bond in the presence of dissolved oxygen.

  8. Relation Between the Adsorbed Quantity and the Immersion Enthalpy in Catechol Aqueous Solutions on Activated Carbons

    OpenAIRE

    Moreno-Piraj?n, Juan Carlos; Blanco, Diego; Giraldo, Liliana

    2011-01-01

    An activated carbon, CarbochemTM—PS230, was modified by chemical and thermal treatment in flow of H2, in order to evaluate the influence of the activated carbon chemical characteristics in the adsorption of the catechol. The catechol adsorption in aqueous solution was studied along with the effect of the pH solution in the adsorption process of modified activated carbons and the variation of immersion enthalpy of activated carbons in the aqueous solutions of catechol. The interaction solid-so...

  9. A Quadrature-Based Tunable Radio-Frequency Sensor for the Detection and Analysis of Aqueous Solutions.

    Science.gov (United States)

    Cui, Yan; He, Yuxi; Wang, Pingshan

    2014-07-01

    A highly tunable and sensitive radio-frequency (RF) sensor is presented for the measurement of aqueous-solution dielectric properties. Two quadrature hybrids are utilized to achieve destructive interference that eliminates the probing signals at both measurement ports. As a result, weak signals of material-under-test (MUT) are elevated for high sensitivity detections at different frequencies. The sensor is demonstrated through measuring 2-propanol-water solution permittivity at 0.01 mole fraction concentration level from ~4 GHz to ~12 GHz. De-ionized water and methanol-water solution are used to calibrate the sensor for quantitative MUT analysis through our proposed model. Micro-meter coplanar waveguides (CPW) are fabricated as RF sensing electrodes. A polydimethylsiloxane (PDMS) microfluidic channel is employed to introduce 250 nL liquid, of which ~1 nL is effectively the MUT. The permittivity and the relaxation time of 2-propanol-water solution are obtained. Compared with our power divider based sensors, the differential reflection coefficients in this work provide additional information that complements the transmission coefficient methods.

  10. Green synthesis of highly concentrated aqueous colloidal solutions of large starch-stabilised silver nanoplatelets.

    Science.gov (United States)

    Cheng, Fei; Betts, Jonathan W; Kelly, Stephen M; Hector, Andrew L

    2015-01-01

    A simple, environmentally friendly and cost-effective method has been developed to prepare a range of aqueous silver colloidal solutions, using ascorbic acid as a reducing agent, water-soluble starch as a combined crystallising, stabilising and solubilising agent, and water as the solvent. The diameter of silver nanoplatelets increases with higher concentrations of AgNO3 and starch. The silver nanoparticles are also more uniform in shape the greater the diameter of the nanoparticles. Colloidal solutions with a very high concentration of large, flat, hexagonal silver nanoplatelets (~230 nm in breadth) have been used to deposit and fix an antibacterial coating of these large starch-stabilised silver nanoplates on commercial cotton fibres, using a simple dip-coating process using water as the solvent, in order to study the dependence of the antibacterial properties of these nanoplatelets on their size. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Oxygen effect in the radiolysis of triton X-100 aqueous solution

    International Nuclear Information System (INIS)

    Perkowski, J.; Mayer, J.

    1994-01-01

    Experiments with Triton X-100 as a model surfactant were performed under steady-state conditions, using deoxygenated solutions as well as those saturated with N 2 O, O 2 or N 2 O/O 2 mixtures. The Triton x-100 decomposition yield was dependent on the O 2 content of the irradiated system. Oxygen promoted surfactant decomposition in aqueous solution containing only Triton X-100. (author) 13 refs.; 1 tab

  12. Relation between the adsorbed quantity and the immersion enthalpy in catechol aqueous solutions on activated carbons.

    Science.gov (United States)

    Moreno-Piraján, Juan Carlos; Blanco, Diego; Giraldo, Liliana

    2012-01-01

    An activated carbon, Carbochem(TM)-PS230, was modified by chemical and thermal treatment in flow of H(2), in order to evaluate the influence of the activated carbon chemical characteristics in the adsorption of the catechol. The catechol adsorption in aqueous solution was studied along with the effect of the pH solution in the adsorption process of modified activated carbons and the variation of immersion enthalpy of activated carbons in the aqueous solutions of catechol. The interaction solid-solution is characterized by adsorption isotherms analysis, at 298 K and pH 7, 9 and 11 in order to evaluate the adsorption value above and below that of the catechol pK(a). The adsorption capacity of carbons increases when the solution pH decreases. The retained amount increases slightly in the reduced carbon to maximum adsorption pH and diminishes in the oxidized carbon. Similar conclusions are obtained from the immersion enthalpies, whose values increase with the solute quantity retained. In granular activated carbon (CAG), the immersion enthalpies obtained are between 21.5 and 45.7 J·g(-1) for catechol aqueous solutions in a range of 20 at 1500 mg·L(-1).

  13. Relation Between the Adsorbed Quantity and the Immersion Enthalpy in Catechol Aqueous Solutions on Activated Carbons

    Directory of Open Access Journals (Sweden)

    Liliana Giraldo

    2011-12-01

    Full Text Available An activated carbon, CarbochemTM—PS230, was modified by chemical and thermal treatment in flow of H2, in order to evaluate the influence of the activated carbon chemical characteristics in the adsorption of the catechol. The catechol adsorption in aqueous solution was studied along with the effect of the pH solution in the adsorption process of modified activated carbons and the variation of immersion enthalpy of activated carbons in the aqueous solutions of catechol. The interaction solid-solution is characterized by adsorption isotherms analysis, at 298 K and pH 7, 9 and 11 in order to evaluate the adsorption value above and below that of the catechol pKa. The adsorption capacity of carbons increases when the solution pH decreases. The retained amount increases slightly in the reduced carbon to maximum adsorption pH and diminishes in the oxidized carbon. Similar conclusions are obtained from the immersion enthalpies, whose values increase with the solute quantity retained. In granular activated carbon (CAG, the immersion enthalpies obtained are between 21.5 and 45.7 J·g−1 for catechol aqueous solutions in a range of 20 at 1500 mg·L−1.

  14. Vibrational dynamics of aqueous hydroxide solutions probed using broadband 2DIR spectroscopy

    International Nuclear Information System (INIS)

    Mandal, Aritra; Tokmakoff, Andrei

    2015-01-01

    We employed ultrafast transient absorption and broadband 2DIR spectroscopy to study the vibrational dynamics of aqueous hydroxide solutions by exciting the O–H stretch vibrations of the strongly hydrogen-bonded hydroxide solvation shell water and probing the continuum absorption of the solvated ion between 1500 and 3800 cm −1 . We observe rapid vibrational relaxation processes on 150–250 fs time scales across the entire probed spectral region as well as slower vibrational dynamics on 1–2 ps time scales. Furthermore, the O–H stretch excitation loses its frequency memory in 180 fs, and vibrational energy exchange between bulk-like water vibrations and hydroxide-associated water vibrations occurs in ∼200 fs. The fast dynamics in this system originate in strong nonlinear coupling between intra- and intermolecular vibrations and are explained in terms of non-adiabatic vibrational relaxation. These measurements indicate that the vibrational dynamics of the aqueous hydroxide complex are faster than the time scales reported for long-range transport of protons in aqueous hydroxide solutions

  15. Extraction of rare earth metals (3) from aqueous solutions containing thorium and uranyl nitrates

    International Nuclear Information System (INIS)

    Pyartman, A.K.; Kopyrin, A.A.; Berinskij, A.E.; Keskinov, V.A.

    2000-01-01

    Isotherms of extraction of rare earth metals (3) from aqueous solutions containing thorium and uranyl nitrates by solutions of tributylphosphate (TBP) and diisooctylmethylphosphonate (DIOMP) in kerosene at 298.15 Deg C and pH 1 are presented. Equations for description of interphase distribution of components of the systems considered are suggested. These equations describe distribution of components adequately in the systems of thorium nitrate (uranyl nitrate) - rare earth nitrates - (TBP, DIOMP) in the case of wide variation of phase compositions. Dependences of separation factors on composition of aqueous phase are considered [ru

  16. A highly sensitive fluorescent probe based on BODIPY for Hg2+ in aqueous solution

    Directory of Open Access Journals (Sweden)

    ZHAO Junwei

    2016-12-01

    Full Text Available A highly sensitive fluorescent probe based on BODIPY and hydrazine for Hg2+ was designed and synthesized.This probe could detect mercury ions in aqueous solutions within 5 min.With the increase of Hg2+ mole concentration,an obvious red shift of UV-Vis absorption wavelength was observed and the fluorescence intensity significantly enhanced.It was found that the fluorescence intensity of an aqueous solution containing 0.1 μmol/L Hg2+ is much stronger than that of blank solution,which indicats that the fluorescent probe has high sensitivity.In addition,other metal ions could not cause the change of fluorescent spectra,which means this probe has good selectivity,as well.

  17. Theoretical study of the influence of chemical reactions and physical parameters on the convective dissolution of CO2 in aqueous solutions

    Science.gov (United States)

    Loodts, Vanessa; Rongy, Laurence; De Wit, Anne

    2014-05-01

    Subsurface carbon sequestration has emerged as a promising solution to the problem of increasing atmospheric carbon dioxide (CO2) levels. How does the efficiency of such a sequestration process depend on the physical and chemical characteristics of the storage site? This question is emblematic of the need to better understand the dynamics of CO2 in subsurface formations, and in particular, the properties of the convective dissolution of CO2 in the salt water of aquifers. This dissolution is known to improve the safety of the sequestration by reducing the risks of leaks of CO2 to the atmosphere. Buoyancy-driven convection makes this dissolution faster by transporting dissolved CO2 further away from the interface. Indeed, upon injection, the less dense CO2 phase rises above the aqueous layer where it starts to dissolve. The dissolved CO2 increases the density of the aqueous solution, thereby creating a layer of denser CO2-rich solution above less dense solution. This unstable density gradient in the gravity field is at the origin of convection. In this framework, we theoretically investigate the effect of CO2 pressure, salt concentration, temperature, and chemical reactions on the dissolution-driven convection of CO2 in aqueous solutions. On the basis of a linear stability analysis, we assess the stability of the time-dependent density profiles developing when CO2 dissolves in an aqueous layer below it. We predict that increasing CO2 pressure destabilizes the system with regard to buoyancy-driven convection, because it increases the density gradient at the origin of the instability. By contrast, increasing salt concentration or temperature stabilizes the system via effects on CO2 solubility, solutal expansion coefficient, diffusion coefficient and on the viscosity and density of the solution. We also show that a reaction of CO2 with chemical species dissolved in the aqueous solution can either enhance or decrease the amplitude of the convective dissolution compared

  18. Unusual radiolytic behavior of neptunium ions in aqueous bicarbonate solutions

    International Nuclear Information System (INIS)

    Shilov, V.P.; Gogolev, A.V.; Pikaev, A.K.

    2000-01-01

    Behavior of neptunium ions in carbonate and bicarbonate aqueous solutions saturated with air, oxygen or argon during gamma radiation ( 60 Co) by doses up to 3 kGy at dose rates 10 and 25 Gy/min was studied by the method of spectrophotometry. It is shown that in neptunium (5) bicarbonate solution nearly complete (95%) neptunium ion oxidation occurs under the effect of radiation, whereas no oxidation is observed in carbonate solution. Radiation-chemical yield of neptunium (5) oxidation and stationary concentration of neptunium (6) ions depend on concentration of bicarbonate-ions. Explanation to the results obtained is made from the viewpoint of potential radiolytic reactions [ru

  19. Some reactions of oxidizing radicals with enzymes in aqueous solution

    International Nuclear Information System (INIS)

    Cundall, R.B.; Bisby, R.H.; Hoe, S.T.; Sims, H.E.; Anderson, R.F.

    1979-01-01

    A range of oxidizing radicals including some inorganic radical anions and the superoxide radical, can be generated by radiolysis of aqueous solutions. These radicals are more selective in their reactions with amino acids than the hydroxyl radical. Factors controlling the apparent reactivity of radical anions with proteins, such as free radical equilibria and ion-binding, are described. The superoxide radical inactivates papain by reaction with the cysteine residue. This reaction has been studied in solutions subjected to radiations of varying linear energy transfer. (Auth.)

  20. The salting-out effect and phase separation in aqueous solutions of tri-sodium citrate and 1-butyl-3-methylimidazolium bromide

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, Rahmat, E-mail: rsadeghi@uok.ac.i [Department of Chemistry, University of Kurdistan, Sanandaj (Iran, Islamic Republic of); Golabiazar, Roonak [Department of Chemistry, University of Kurdistan, Sanandaj (Iran, Islamic Republic of); Shekaari, Hemayat [Department of Chemistry, Faculty of Science, University of Mohaghegh Ardabili, Ardabil (Iran, Islamic Republic of)

    2010-04-15

    The aim of this work is to obtain further evidence about the salting-out effect produced by the addition of tri-sodium citrate to aqueous solutions of water miscible ionic liquid 1-butyl-3-methylimidazolium bromide ([C{sub 4}mim][Br]) by evaluating the effect of tri-sodium citrate on the thermodynamic properties of aqueous solutions of this ionic liquid. Experimental measurements of density and sound velocity at different temperatures ranging from (288.15 to 308.15) K, the refractive index at 308.15 K and the liquid-liquid phase diagram at different temperatures ranging from (288.15 to 338.15) K for aqueous solutions containing 1-butyl-3-methylimidazolium bromide ([C{sub 4}mim][Br]) and tri-sodium citrate (Na{sub 3}Cit) are taken. The apparent molar volume of transfer of [C{sub 4}mim][Br] from water to aqueous solutions of Na{sub 3}Cit have positive values and it increases by increasing salt molality. Although at high IL molality, the apparent molar isentropic compressibility shows similar behaviour with that of the apparent molar volume. However at low concentrations of IL, the apparent molar isentropic compressibility of transfer of [C{sub 4}mim][Br] from water to aqueous solutions of Na{sub 3}Cit have negative values. The effects of temperature and the addition of Na{sub 3}Cit and [C{sub 4}mim][Br] on the liquid-liquid phase diagram of the investigated system have been studied. It was found that an increase in temperature caused the expansion of the one-phase region. The presence of Na{sub 3}Cit triggers a salting-out effect, leading to significant upward shifts of the liquid-liquid de-mixing temperatures of the system. The effect of temperature on the phase-forming ability in the system investigated has been studied based on a salting-out coefficient obtained from fitting the binodal values to a Setschenow-type equation for each temperature. Based on cloud point values, the energetics of the clouding process have been estimated and it was found that both of

  1. Behavior of supercooled aqueous solutions stemming from hidden liquid–liquid transition in water

    Energy Technology Data Exchange (ETDEWEB)

    Biddle, John W.; Holten, Vincent; Anisimov, Mikhail A., E-mail: anisimov@umd.edu [Institute for Physical Science and Technology and Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, Maryland 20742 (United States)

    2014-08-21

    A popular hypothesis that explains the anomalies of supercooled water is the existence of a metastable liquid–liquid transition hidden below the line of homogeneous nucleation. If this transition exists and if it is terminated by a critical point, the addition of a solute should generate a line of liquid–liquid critical points emanating from the critical point of pure metastable water. We have analyzed thermodynamic consequences of this scenario. In particular, we consider the behavior of two systems, H{sub 2}O-NaCl and H{sub 2}O-glycerol. We find the behavior of the heat capacity in supercooled aqueous solutions of NaCl, as reported by Archer and Carter [J. Phys. Chem. B 104, 8563 (2000)], to be consistent with the presence of the metastable liquid–liquid transition. We elucidate the non-conserved nature of the order parameter (extent of “reaction” between two alternative structures of water) and the consequences of its coupling with conserved properties (density and concentration). We also show how the shape of the critical line in a solution controls the difference in concentration of the coexisting liquid phases.

  2. Behavior of supercooled aqueous solutions stemming from hidden liquid–liquid transition in water

    International Nuclear Information System (INIS)

    Biddle, John W.; Holten, Vincent; Anisimov, Mikhail A.

    2014-01-01

    A popular hypothesis that explains the anomalies of supercooled water is the existence of a metastable liquid–liquid transition hidden below the line of homogeneous nucleation. If this transition exists and if it is terminated by a critical point, the addition of a solute should generate a line of liquid–liquid critical points emanating from the critical point of pure metastable water. We have analyzed thermodynamic consequences of this scenario. In particular, we consider the behavior of two systems, H 2 O-NaCl and H 2 O-glycerol. We find the behavior of the heat capacity in supercooled aqueous solutions of NaCl, as reported by Archer and Carter [J. Phys. Chem. B 104, 8563 (2000)], to be consistent with the presence of the metastable liquid–liquid transition. We elucidate the non-conserved nature of the order parameter (extent of “reaction” between two alternative structures of water) and the consequences of its coupling with conserved properties (density and concentration). We also show how the shape of the critical line in a solution controls the difference in concentration of the coexisting liquid phases

  3. Dynamics of anion exchange of lanthanides in aqueous-organic complexing media

    International Nuclear Information System (INIS)

    Sheveleva, I.V.; Bogatyrev, I.O.

    1987-01-01

    Effect of organic solvents (ethanol, acetone, acetonitrile) on change in kinetic parameters of the anion exchange process (anion-exchange column chromatography) of r.e.e. (europium and gadolinium) in complexing nitric acid media has been studied. It is established that complex LnA 4 anion is the only sorbing form of europium and gadolinium on anionite. When the organic component content of the solution being the same, the dynamic parameters of lanthanide exchange have higher values in aqueous-acetonitrile and aqueous-acetone media in comparison with aqueous-enthanol solutions of nitric acid. Lesser mobility of complex lanthanide anions in aqueous-alcoholic solutions can be explained by stronger solvation in the presence of solvents with higher acceptor properties

  4. Human Lactoferricin Is Partially Folded in Aqueous Solution and Is Better Stabilized in a Membrane Mimetic Solvent

    Science.gov (United States)

    Hunter, Howard N.; Demcoe, A. Ross; Jenssen, Håvard; Gutteberg, Tore J.; Vogel, Hans J.

    2005-01-01

    Lactoferricins are highly basic bioactive peptides that are released in the stomach through proteolytic cleavage of various lactoferrin proteins. Here we have determined the solution structure of human lactoferricin (LfcinH) by conventional two-dimensional nuclear magnetic resonance methods in both aqueous solution and a membrane mimetic solvent. Unlike the 25-residue bovine lactoferricin (LfcinB), which adopts a somewhat distorted antiparallel β sheet, the longer LfcinH peptide shows a helical content from Gln14 to Lys29 in the membrane mimetic solvent but a nonexistent β-sheet character in either the N- or C-terminal regions of the peptide. The helical characteristic of the LfcinH peptide resembles the conformation that this region adopts in the crystal structure of the intact protein. The LfcinH structure determined in aqueous solution displays a nascent helix in the form of a coiled conformation in the region from Gln14 to Lys29. Numerous hydrophobic interactions create the basis for the better-defined overall structure observed in the membrane mimetic solvent. The 49-residue LfcinH peptide isolated for these studies was found to be slightly longer than previously reported peptide preparations and was found to have an intact peptide bond between residues Ala11 and Val12. The distinct solution structures of LfcinH and LfcinB represent a novel difference in the physical properties of these two peptides, which contributes to their unique physiological activities. PMID:16048952

  5. Physicochemical analysis of cryocrystallization processes of aqueous solutions of yttrium, barium, copper nitrates and their mixtures

    International Nuclear Information System (INIS)

    Kulakov, A.B.; Mozhaev, A.P.; Tesker, A.M.; Churagulov, B.R.

    1992-01-01

    Products of fast hardening of aqueous solutions of different concentration of yttrium, barium copper nitrates and their mixtures including mixture of three nitrates with molar ratio equal to 1:2:3 used for synthesis of YBa 2 Cu 3 O 7-x HTSC by cryochemical technique, in liquid nitrogen, are studied using low-temperature, differential thermal and X-ray phase analyses. Aqueous solutions of barium, copper, yttrium nitrates are shown to belong to three different classes which differ in behaviour at fast cooling and subsequent slow heating. Cryogranulate at YBa 2 Cu 2 O 7-x synthesis using cryochemical technique represents mixture of X-ray amorphous Ba(NO 3 ) 2 , crystalline Cu(NO 3 ) 2 ·6H 2 O and ice, as well as, supercooled aqueous solution of yttrium and copper nitrates

  6. Characterization of aqueous silver nitrate solutions for leakage tests

    Directory of Open Access Journals (Sweden)

    José Ferreira Costa

    2011-06-01

    Full Text Available OBJECTIVE: To determine the pH over a period of 168 h and the ionic silver content in various concentrations and post-preparation times of aqueous silver nitrate solutions. Also, the possible effects of these factors on microleakage test in adhesive/resin restorations in primary and permanent teeth were evaluated. MATERIAL AND METHODS: A digital pHmeter was used for measuring the pH of the solutions prepared with three types of water (purified, deionized or distilled and three brands of silver nitrate salt (Merck, Synth or Cennabras at 0, 1, 2, 24, 48, 72, 96 and 168 h after preparation, and storage in transparent or dark bottles. Ionic silver was assayed according to the post-preparation times (2, 24, 48, 72, 96, 168 h and concentrations (1, 5, 25, 50% of solutions by atomic emission spectrometry. For each sample of each condition, three readings were obtained for calculating the mean value. Class V cavities were prepared with enamel margins on primary and permanent teeth and restored with the adhesive systems OptiBond FL or OptiBond SOLO Plus SE and the composite resin Filtek Z-250. After nail polish coverage, the permanent teeth were immersed in 25% or 50% AgNO3 solution and the primary teeth in 5% or 50% AgNO3 solutions for microleakage evaluation. ANOVA and the Tukey's test were used for data analyses (α=5%. RESULTS: The mean pH of the solutions ranged from neutral to alkaline (7.9±2.2 to 11.8±0.9. Mean ionic silver content differed depending on the concentration of the solution (4.75±0.5 to 293±15.3 ppm. In the microleakage test, significant difference was only observed for the adhesive system factor (p=0.000. CONCLUSIONS: Under the tested experimental conditions and based on the obtained results, it may be concluded that the aqueous AgNO3 solutions: have neutral/alkaline pH and service life of up to 168 h; the level of ionic silver is proportional to the concentration of the solution; even at 5% concentration, the solutions were

  7. Conformations and solution properties of star-branched polyelectrolytes

    NARCIS (Netherlands)

    Borisov, O.V.; Zhulina, E.B.; Leermakers, F.A.M.; Ballauff, M.; Muller, A.H.E.

    2011-01-01

    Aqueous solutions of star-like polyelectrolytes (PEs) exhibit distinctive features that originate from the topological complexity of branched macromolecules. In a salt-free solution of branched PEs, mobile counterions preferentially localize in the intramolecular volume of branched macroions.

  8. Determination of Ga in aqueous uranium solution by EDXRF

    International Nuclear Information System (INIS)

    Natarajan, V.; Purohit, P.J.; Goyal, Neelam; Seshagiri, T.K.; Godbole, S.V.; Manchanda, V.K.

    2009-01-01

    A method has been developed using EDXRF technique for the determination of gallium in aqueous solution using a set of solution standards in the concentration range 20-5000 μg/ml. When this method was applied to U containing solutions, the estimated values were found to be lower due to matrix effects. Hence the method was modified in order to determine gallium in the presence of uranium using lower tube current and another set of standards with U concentration at 100 mg/ml. The method was applicable for the estimation of Ga from 50 μg/ml to 5mg/ml (i.e.0.05-5% Ga in U). Three synthetic samples were analysed by the present methods in order to evaluate the method for its reliability and reproducibility. (author)

  9. Annealing effects on the optical and morphological properties of ZnO nanorods on AZO substrate by using aqueous solution method at low temperature.

    Science.gov (United States)

    Hang, Da-Ren; Islam, Sk Emdadul; Sharma, Krishna Hari; Kuo, Shiao-Wei; Zhang, Cheng-Zu; Wang, Jun-Jie

    2014-01-01

    Vertically aligned ZnO nanorods (NRs) on aluminum-doped zinc oxide (AZO) substrates were fabricated by a single-step aqueous solution method at low temperature. In order to optimize optical quality, the effects of annealing on optical and structural properties were investigated by scanning electron microscopy, X-ray diffraction, photoluminescence (PL), and Raman spectroscopy. We found that the annealing temperature strongly affects both the near-band-edge (NBE) and visible (defect-related) emissions. The best characteristics have been obtained by employing annealing at 400°C in air for 2 h, bringing about a sharp and intense NBE emission. The defect-related recombinations were also suppressed effectively. However, the enhancement decreases with higher annealing temperature and prolonged annealing. PL study indicates that the NBE emission is dominated by radiative recombination associated with hydrogen donors. Thus, the enhancement of NBE is due to the activation of radiative recombinations associated with hydrogen donors. On the other hand, the reduction of visible emission is mainly attributed to the annihilation of OH groups. Our results provide insight to comprehend annealing effects and an effective way to improve optical properties of low-temperature-grown ZnO NRs for future facile device applications.

  10. Predicting adsorptive removal of chlorophenol from aqueous solution using artificial intelligence based modeling approaches.

    Science.gov (United States)

    Singh, Kunwar P; Gupta, Shikha; Ojha, Priyanka; Rai, Premanjali

    2013-04-01

    The research aims to develop artificial intelligence (AI)-based model to predict the adsorptive removal of 2-chlorophenol (CP) in aqueous solution by coconut shell carbon (CSC) using four operational variables (pH of solution, adsorbate concentration, temperature, and contact time), and to investigate their effects on the adsorption process. Accordingly, based on a factorial design, 640 batch experiments were conducted. Nonlinearities in experimental data were checked using Brock-Dechert-Scheimkman (BDS) statistics. Five nonlinear models were constructed to predict the adsorptive removal of CP in aqueous solution by CSC using four variables as input. Performances of the constructed models were evaluated and compared using statistical criteria. BDS statistics revealed strong nonlinearity in experimental data. Performance of all the models constructed here was satisfactory. Radial basis function network (RBFN) and multilayer perceptron network (MLPN) models performed better than generalized regression neural network, support vector machines, and gene expression programming models. Sensitivity analysis revealed that the contact time had highest effect on adsorption followed by the solution pH, temperature, and CP concentration. The study concluded that all the models constructed here were capable of capturing the nonlinearity in data. A better generalization and predictive performance of RBFN and MLPN models suggested that these can be used to predict the adsorption of CP in aqueous solution using CSC.

  11. Removal of cadmium(II) from aqueous solutions by steam-activated ...

    African Journals Online (AJOL)

    Removal of cadmium(II) from aqueous solutions by steam-activated sulphurised carbon prepared from sugar-cane bagasse pith: kinetics and equilibrium studies. ... the maximum adsorption capacity of SA-S-C calculated by the Langmuir isotherm is 149.93 mg/g at 30°C. Acid regeneration was tried for several cycles with a ...

  12. Kinetics of absorption of carbon dioxide in aqueous ammonia solutions

    NARCIS (Netherlands)

    Derks, P. W. J.; Versteeg, G. F.

    2009-01-01

    In the present work the absorption of carbon dioxide into aqueous ammonia solutions has been studied in a stirred cell reactor, at low temperatures and ammonia concentrations ranging from 0.1 to about 7 kmol m-3. The absorption experiments were carried out at conditions where the so-called pseudo

  13. Equilibrium Sorption Studies of Hg (II) Ions from Aqueous Solution ...

    African Journals Online (AJOL)

    The potential of swamp arum (Lasimorpha senegalensis) seeds as a low-cost adsorbent for the removal of Hg (II) ions from aqueous solution was investigated in this study. The influence of initial metal concentration on the percent adsorption of Hg (II) ions onto powdered swamp arum seeds was studied in a batch system ...

  14. The solubility of hydrogen sulfide in aqueous N-methyldiethanolamine solutions

    NARCIS (Netherlands)

    Huttenhuis, P.J.G.; Agrawal, N.J.; Versteeg, G.F.

    2008-01-01

    In this work the electrolyte equation of state as developed previously for the system MDEA-H2O-CO2-CH4 was further developed for the system MDEA-H2O-H2S-CH4. With this thermodynamic equilibrium model the total solubility of hydrogen sulfide and the speciation in aqueous solutions of

  15. Formation of the second organic phase during uranyl nitrate extraction from aqueous solution by 30% tributylphosphate solution in paraffin

    International Nuclear Information System (INIS)

    Yhrkin, V.G.

    1996-01-01

    For extraction systems aqueous solution of uranyl nitrate-30% solution of tributylphosphate in individual paraffins from C 13 to C 17 the influence of the second organic phase of uranyl nitrate concentration in aqueous and organic phases, the length of hydrocarbon chain of paraffin hydrocarbon and temperature from 25 to 50 deg C on formation conditions has been defected. A special method of achieving the conditions of organic phase stratification from three-phase region, involving definition of equilibrium phases composition by density and refractive index, has been elaborated for more precise definition of organic phase homogeneity region. It has been revealed that without addition of nitric acid to uranyl nitrate solution the organic phase homogeneity limits can be achieved solely on paraffins C 15 , C 16 and C 17 and only under conditions similar to equeous phase saturation in terms of uranyl nitrate. 16 refs., 2 figs

  16. RECOVERY OF CARBOXYLIC ACIDS FROM AQUEOUS SOLUTIONS BY LIQUID-LIQUID EXTRACTION WITH A TRIISOOCTYLAMINE DILUENT SYSTEM

    Directory of Open Access Journals (Sweden)

    G. Malmary

    2001-12-01

    Full Text Available Tertiary alkylamines in solution with organic diluents are attractive extractants for the recovery of carboxylic acids from dilute aqueous phases. The aim of this study was to investigate the mechanism for extraction of organic acids from water by a long-chain aliphatic tertiary amine. In order to attain this objective, we studied the liquid-liquid equilibria between the triisooctylamine + 1-octanol + n-heptane system as solvent and an aqueous solution of an individual carboxylic acid such as citric, lactic and malic acids. The experiments showed that the partition coefficient for a particular organic acid depends on the kind of solute, notably when the acid concentration in the aqueous phase is low. A mathematical model, where both chemical association and physical distribution are taken into consideration, is proposed. The model suggests that the various complexes obtained between amine and organic acids contribute to the distribution of the solute between the coexisting phases in equilibrium.

  17. Radiation crosslinking of methylcellulose and hydroxyethylcellulose in concentrated aqueous solutions

    International Nuclear Information System (INIS)

    Wach, Radoslaw A.; Mitomo, Hiroshi; Nagasawa, Naotsugu; Yoshii, Fumio

    2003-01-01

    The effects of ionizing radiation on aqueous solutions of cellulose ethers, methylcellulose (MC) and hydroxyethylcellulose (HEC) were investigated. The well-established knowledge states that cellulose and its derivatives belong to degrading type of polymers. However, in our study intermolecular crosslinking initiated by gamma rays or electron beam leaded to the formation of insoluble gel. This is an opposite effect of irradiation to the degradation. Paste-like form of the initial specimen, i.e. concentration 20-30%, when water plasticizes the bulk of polymer; and a high dose rate were favorable for hydrogel formation. Gel fraction up to 60% and 70% was obtained from solutions of HEC and MC, respectively. Produced hydrogels swell markedly in aqueous media by imbibing and holding the solvent. Radiation parameters of irradiation, such as yields of degradation and crosslinking and the gelation dose, were evaluated by sol-gel analysis on the basis of Charlesby-Rosiak equation. Despite of the crosslinked structure, obtained hydrogels can be included into the group of biodegradable materials. They undergo decomposition by the action of cellulase enzyme or microorganisms from compost

  18. Application of Homotopy-Perturbation Method to Nonlinear Ozone Decomposition of the Second Order in Aqueous Solutions Equations

    DEFF Research Database (Denmark)

    Ganji, D.D; Miansari, Mo; B, Ganjavi

    2008-01-01

    In this paper, homotopy-perturbation method (HPM) is introduced to solve nonlinear equations of ozone decomposition in aqueous solutions. HPM deforms a di¢ cult problem into a simple problem which can be easily solved. The effects of some parameters such as temperature to the solutions are consid......In this paper, homotopy-perturbation method (HPM) is introduced to solve nonlinear equations of ozone decomposition in aqueous solutions. HPM deforms a di¢ cult problem into a simple problem which can be easily solved. The effects of some parameters such as temperature to the solutions...

  19. Dynamical structure of water in aqueous solutions of D-glucose and D-galactose by low-frequency Raman scattering

    Science.gov (United States)

    Wang, Yan; Tominaga, Yasunori

    1994-02-01

    Low-frequency depolarized Raman spectra of aqueous solutions of D-glucose and D-galactose have been investigated in the frequency region from -250 cm-1 to 250 cm-1 at 30.0 °C as a function of concentration up to 0.04 molar ratio. The dynamical structure of water in aqueous solution is analyzed by using the reduced Raman spectrum χ`(ν¯), which corresponds to the imaginary part of the dynamical susceptibility. The reduced spectrum is fitted with the superposition of one Cole-Cole type relaxation mode and two damped harmonic oscillator modes by a nonlinear least-squares fitting. The effects of D-glucose and D-galactose on the dynamical structure of water in aqueous solution are similar. The relaxation time of hydrogen bond among water molecules becomes slower with increasing sugar concentration. The characteristic frequencies of stretching-like and bending-like vibrations among water molecules do not change in both D-glucose and D-galactose aqueous solutions.

  20. Probing Ionic Liquid Aqueous Solutions Using Temperature of Maximum Density Isotope Effects

    Directory of Open Access Journals (Sweden)

    Mohammad Tariq

    2013-03-01

    Full Text Available This work is a new development of an extensive research program that is investigating for the first time shifts in the temperature of maximum density (TMD of aqueous solutions caused by ionic liquid solutes. In the present case we have compared the shifts caused by three ionic liquid solutes with a common cation—1-ethyl-3-methylimidazolium coupled with acetate, ethylsulfate and tetracyanoborate anions—in normal and deuterated water solutions. The observed differences are discussed in terms of the nature of the corresponding anion-water interactions.