WorldWideScience

Sample records for aptima combo2 assay

  1. HPV Genotyping from the high risk mRNA Aptima assay- a direct approach using DNA from Aptima sample tubes.

    Science.gov (United States)

    Lillsunde Larsson, G; Kaliff, M; Bergengren, L; Karlsson, M G; Helenius, G

    2016-09-01

    The underlying cause of cervical cancer is an infection with the human papilloma virus (HPV) and HPV testing can be used for cervical cancer screening. The Aptima HPV assay from Hologic is an mRNA HPV test used to identify clinically relevant infections but the method does not discriminate between the different high risk genotypes. The aim of the current study was to evaluate if analyzed Aptima sample transfer tubes could be used as a source for HPV genotyping, using sample DNA. Study samples (n=108); were HPV-tested with mRNA Aptima assay and in parallel DNA was extracted and genotyped with Anyplex II HPV28. Analyzed mRNA Aptima tubes were thereafter used as source for a second DNA extraction and genotyping. Using mRNA Aptima result as reference, 90% of the samples (35/39) were high risk positive with the Anyplex II HPV28. Cohen's kappa 0.78 (95% CI: 0.66-0.90), sensitivity 0.90 (95% CI: 0.76-0.97) and specificity 0.90 (95% CI: 0.80-0.96). Two discordant samples carried low-risk genotypes (HPV 82 and HPV 44) and two were negative. DNA-genotyping results, in parallel to and after mRNA testing, were compared and differed significantly (McNemar test: P=0.021) possibly due to sample extraction volume difference. Cohen's kappa 0.81 (95% CI: 0.70-0.92), sensitivity 0.85 (95% CI: 0.74-0.93) and specificity 0.98 (95% CI: 0.88-1.00). In conclusion, analyzed mRNA Aptima sample tubes could be used as a source for DNA HPV genotyping. The sample volume used for extraction needs to be further explored.

  2. Prevalence of Human Papillomavirus Infection in Unselected SurePath Samples Using the APTIMA HPV mRNA Assay

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Preisler, Sarah; Ejegod, Ditte M;

    2013-01-01

    The APTIMA Human Papillomavirus (HPV) Assay detects E6/E7 mRNA from 14 human papillomavirus genotypes. Horizon was a population-based split-sample study among well-screened women, with an aim to compare APTIMA, Hybrid Capture 2 (HC2), and liquid-based cytology (LBC) using SurePath samples. APTIMA...... agreement between APTIMA and HC2. This is the first APTIMA study using SurePath samples on the PANTHER platform. The trends in positivity rates on SurePath samples for APTIMA, HC2, and LBC were consistent with studies based on PreservCyt samples, and the agreement between the two HPV assays was substantial....... The high proportions of women testing positive suggest that in countries with a high HPV prevalence, caution will be needed if HPV tests, including mRNA-based tests, are to replace LBC....

  3. APTIMA assay on SurePath liquid-based cervical samples compared to endocervical swab samples facilitated by a real time database

    Directory of Open Access Journals (Sweden)

    Khader Samer

    2010-01-01

    Full Text Available Background: Liquid-based cytology (LBC cervical samples are increasingly being used to test for pathogens, including: HPV, Chlamydia trachomatis (CT and Neisseria gonorrhoeae (GC using nucleic acid amplification tests. Several reports have shown the accuracy of such testing on ThinPrep (TP LBC samples. Fewer studies have evaluated SurePath (SP LBC samples, which utilize a different specimen preservative. This study was undertaken to assess the performance of the Aptima Combo 2 Assay (AC2 for CT and GC on SP versus endocervical swab samples in our laboratory. Materials and Methods: The live pathology database of Montefiore Medical Center was searched for patients with AC2 endocervical swab specimens and SP Paps taken the same day. SP samples from CT- and/or GC-positive endocervical swab patients and randomly selected negative patients were studied. In each case, 1.5 ml of the residual SP vial sample, which was in SP preservative and stored at room temperature, was transferred within seven days of collection to APTIMA specimen transfer tubes without any sample or patient identifiers. Blind testing with the AC2 assay was performed on the Tigris DTS System (Gen-probe, San Diego, CA. Finalized SP results were compared with the previously reported endocervical swab results for the entire group and separately for patients 25 years and younger and patients over 25 years. Results: SP specimens from 300 patients were tested. This included 181 swab CT-positive, 12 swab GC-positive, 7 CT and GC positive and 100 randomly selected swab CT and GC negative patients. Using the endocervical swab results as the patient′s infection status, AC2 assay of the SP samples showed: CT sensitivity 89.3%, CT specificity 100.0%; GC sensitivity and specificity 100.0%. CT sensitivity for patients 25 years or younger was 93.1%, versus 80.7% for patients over 25 years, a statistically significant difference (P = 0.02. Conclusions: Our results show that AC2 assay of 1.5 ml SP

  4. A review of the clinical performance of the Aptima HPV assay.

    Science.gov (United States)

    Haedicke, Juliane; Iftner, Thomas

    2016-03-01

    This comprehensive review compiles published data from 62 original articles comparing different HPV tests and one meta-analysis on the clinical performance of the Aptima HR HPV (AHPV) assay in either screening or referral populations as well as for the purpose of test of cure. A number of publications with technical issues were also considered. Besides a brief introduction in the development of E6/E7 mRNA testing, the review summarizes data on analytical sensitivies and specificities, as well as on clinical sensitivity, specificity, NPV and PPV with histological endpoints CIN2+ and CIN3+, where available. Although most studies were of cross-sectional design, five studies with a longitudinal prospective design or component were identified. In addition to the study design, sample size, age and CIN2/3+ prevalence of the respective cohort are listed. This allows direct comparison of the published data in the respective groups. One major outcome of this review is the remarkably stable similar sensitivities of AHPV and HC2 independent from study design for detection of CIN2/3+ combined with a higher specificity of the AHPV. The second outcome was the longitudinal predictive value derived from registry linkage and other prospective studies that would support the applicability of the AHPV test in primary screening with at least a three year screening interval. PMID:26614686

  5. Evaluation of Performance Characteristics of the Aptima HIV-1 Quant Dx Assay for Detection and Quantitation of Human Immunodeficiency Virus Type 1 in Plasma and Cervicovaginal Lavage Samples.

    Science.gov (United States)

    Sam, Soya S; Kurpewski, Jaclynn R; Cu-Uvin, Susan; Caliendo, Angela M

    2016-04-01

    Quantification of HIV-1 RNA has become the standard of care in the clinical management of HIV-1-infected individuals. The objective of this study was to evaluate performance characteristics and relative workflow of the Aptima HIV-1 Quant Dx assay in comparison with the Abbott RealTime HIV-1 assay using plasma and cervicovaginal lavage (CVL) specimens. Assay performance was evaluated by using an AcroMetrix HIV-1 panel, AcroMetrix positive controls, Qnostics and SeraCare HIV-1 evaluation panels, 208 clinical plasma samples, and 205 matched CVL specimens on the Panther and m2000 platforms. The Aptima assay demonstrated good linearity over the quantification range tested (2 to 5 log10copies/ml), and there was strong linear correlation between the assays (R(2)= 0.99), with a comparable coefficient of variance of laboratories demanding high-throughput sample processing. PMID:26842702

  6. Evaluation of the Aptima(®) HIV-1 Quant Dx assay for HIV-1 RNA viral load detection and quantitation in plasma of HIV-1-infected individuals: A comparison with Abbott RealTime HIV-1 assay.

    Science.gov (United States)

    Amendola, Alessandra; Pisciotta, Maria; Aleo, Loredana; Ferraioli, Valeria; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2016-09-01

    The Hologic Aptima(®) HIV-1 Quant Dx assay (Aptima HIV) is a real-time transcription-mediated amplification method CE-approved for use in diagnosis and monitoring of HIV-1 infection. The analytical performance of this new assay was compared to the FDA-approved Abbott RealTime HIV-1 (RealTime). The evaluation was performed using 220 clinical plasma samples, the WHO 3rd HIV-1 International Standard, and the QCMD HIV-1 RNA EQA. Concordance on qualitative results, correlation between quantitative results, accuracy, and reproducibility of viral load data were analyzed. The ability to measure HIV-1 subtypes was assessed on the second WHO International Reference Preparation Panel for HIV-1 Subtypes. With clinical samples, inter-assay agreement for qualitative results was high (91.8%) with Cohen's kappa statistic equal to 0.836. For samples with quantitative results in both assays (n = 93), Lin's concordance correlation coefficient was 0.980 (P R(2)  > 0.970) and showed higher sensitivity compared to RealTime being able to detect HIV-1 RNA in 10 out of 10 replicates containing down to 7 cp/ml (20 IU/ml). Reproducibility was very high, even at low HIV-1 RNA values. The Aptima HIV was able to detect and accurately quantify all the main HIV-1 subtypes in both reference panels and clinical samples. Besides excellent performance, Aptima HIV shows full automation, ease of use, and improved workflow compared to RealTime. J. Med. Virol. 88:1535-1544, 2016. © 2016 Wiley Periodicals, Inc. PMID:26864171

  7. Cross-reactivity profiles of hybrid capture II, cobas, and APTIMA human papillomavirus assays

    DEFF Research Database (Denmark)

    Preisler, Sarah Spruce; Rebolj, Matejka; Ejegod, Ditte Møller;

    2016-01-01

    evaluated to what extent these can be explained by cross-reactivity, i.e. positive test results without evidence of high-risk HPV genotypes. The patterns of cross-reactivity have been thoroughly studied for hybrid capture II (HC2) but not yet for newer HPV assays although the manufacturers claimed......-reactivity should be addressed in EU tenders, as this primarily technical shortcoming imposes additional costs on the screening programmes....

  8. Performance of the Aptima High-Risk Human Papillomavirus mRNA Assay in a Referral Population in Comparison with Hybrid Capture 2 and Cytology▿

    Science.gov (United States)

    Clad, Andreas; Reuschenbach, Miriam; Weinschenk, Johanna; Grote, Ruth; Rahmsdorf, Janina; Freudenberg, Nikolaus

    2011-01-01

    This study compared the Aptima human papillomavirus (HPV) (AHPV; Gen-Probe Incorporated) assay, which detects E6/E7 mRNA from 14 high-risk types, the Hybrid Capture 2 HPV DNA (HC2; Qiagen Incorporated) test, and repeat cytology for their ability to detect high-grade cervical lesions (cervical intraepithelial neoplasia grade 2+ [CIN2+]) in women referred to colposcopy due to an abnormal Papanicolaou (Pap) smear. A total of 424 clinical specimens, stored in liquid-based cytology (LBC) vials at room temperature for up to 3 years, were tested by repeat cytology, the AHPV assay, and the HC2 test. Assay results were compared to each other and to histology results. The overall agreement between the AHPV assay and the HC2 test was 88.4%. The sensitivity (specificity) of cytology, the HC2 test, and the AHPV assay for the detection of CIN2+ was 84.9% (66.3%), 91.3% (61.0%), and 91.7% (75.0%) and for the detection of CIN3+ was 93.9% (54.4%), 95.7% (46.0%), and 98.2% (56.3%), respectively. Of the disease-positive specimens containing high-risk HPV (HR HPV) DNA as determined by Linear Array (Roche Diagnostics), the AHPV assay missed 3 CIN2 and 1 microfocal CIN3 specimen, while the HC2 test missed 6 CIN2, 4 CIN3, and 1 cervical carcinoma specimen. The AHPV assay had a sensitivity similar to but a specificity significantly higher (P < 0.0001) than the HC2 test for the detection of CIN2+. The AHPV assay was significantly more sensitive (P = 0.0041) and significantly more specific (P = 0.0163) than cytology for the detection of disease (CIN2+). PMID:21191046

  9. Performance of the Aptima high-risk human papillomavirus mRNA assay in a referral population in comparison with Hybrid Capture 2 and cytology.

    Science.gov (United States)

    Clad, Andreas; Reuschenbach, Miriam; Weinschenk, Johanna; Grote, Ruth; Rahmsdorf, Janina; Freudenberg, Nikolaus

    2011-03-01

    This study compared the Aptima human papillomavirus (HPV) (AHPV; Gen-Probe Incorporated) assay, which detects E6/E7 mRNA from 14 high-risk types, the Hybrid Capture 2 HPV DNA (HC2; Qiagen Incorporated) test, and repeat cytology for their ability to detect high-grade cervical lesions (cervical intraepithelial neoplasia grade 2+ [CIN2+]) in women referred to colposcopy due to an abnormal Papanicolaou (Pap) smear. A total of 424 clinical specimens, stored in liquid-based cytology (LBC) vials at room temperature for up to 3 years, were tested by repeat cytology, the AHPV assay, and the HC2 test. Assay results were compared to each other and to histology results. The overall agreement between the AHPV assay and the HC2 test was 88.4%. The sensitivity (specificity) of cytology, the HC2 test, and the AHPV assay for the detection of CIN2+ was 84.9% (66.3%), 91.3% (61.0%), and 91.7% (75.0%) and for the detection of CIN3+ was 93.9% (54.4%), 95.7% (46.0%), and 98.2% (56.3%), respectively. Of the disease-positive specimens containing high-risk HPV (HR HPV) DNA as determined by Linear Array (Roche Diagnostics), the AHPV assay missed 3 CIN2 and 1 microfocal CIN3 specimen, while the HC2 test missed 6 CIN2, 4 CIN3, and 1 cervical carcinoma specimen. The AHPV assay had a sensitivity similar to but a specificity significantly higher (P < 0.0001) than the HC2 test for the detection of CIN2+. The AHPV assay was significantly more sensitive (P = 0.0041) and significantly more specific (P = 0.0163) than cytology for the detection of disease (CIN2+).

  10. The APTIMA HPV assay versus the Hybrid Capture 2 test in triage of women with ASC-US or LSIL cervical cytology: a meta-analysis of the diagnostic accuracy.

    Science.gov (United States)

    Arbyn, Marc; Roelens, Jolien; Cuschieri, Kate; Cuzick, Jack; Szarewski, Ann; Ratnam, Sam; Reuschenbach, Miriam; Belinson, Suzanne; Belinson, Jerome L; Monsonego, Joseph

    2013-01-01

    Testing for DNA of 13 high-risk HPV types with the Hybrid Capture 2 (HC2) test has consistently been shown to perform better in triage of women with cervical cytology results showing atypical squamous cells of undetermined significance (ASC-US) but often not in triage of low-grade squamous intraepithelial lesions (LSIL) detected in cervical cancer screening. In a meta-analysis, we compared the accuracy of the APTIMA HPV test, which identifies RNA of 14 high-risk HPV types, to HC2 for the triage of women with ASC-US or LSIL. Literature search-targeted studies where the accuracy of APTIMA HPV and HC2 for detection of underlying CIN2/3+ was assessed concomitantly including verification of all cases of ASC-US and LSIL. HSROC (Hierarchical Summary ROC) curve regression was used to compute the pooled absolute and relative sensitivity and specificity. Eight studies, comprising 1,839 ASC-US and 1,887 LSIL cases, were retrieved. The pooled sensitivity and specificity of APTIMA to triage ASC-US to detect underlying CIN3 or worse was 96.2% (95% CI = 91.7-98.3%) and 54.9% (95% CI = 43.5-65.9%), respectively. APTIMA and HC2 showed similar pooled sensitivity; however, the specificity of the former was significantly higher (ratio: 1.19; 95% CI = 1.08-1.31 for CIN2+). The pooled sensitivity and specificity of APTIMA to triage LSIL were 96.7% (95% CI = 91.4-98.9%) and 38.7% (95% CI = 30.5-47.6%) for CIN3+. APTIMA was as sensitive as HC2 but more specific (ratio: 1.35; 95% CI = 1.11-1.66). Results were similar for detection of CIN2 or worse. In both triage of ASC-US and LSIL, APTIMA is as sensitive but more specific than HC2 for detecting cervical precancer.

  11. Human Papillomavirus Assays and Cytology in Primary Cervical Screening of Women Aged 30 Years and Above

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Bonde, Jesper; Preisler, Sarah;

    2016-01-01

    In women aged ≥30 years, Human Papillomavirus testing will replace cytology for primary cervical screening. We compared Hybrid Capture 2 (HC2), cobas, CLART, and APTIMA HPV assays with cytology on 2869 SurePath samples from women undergoing routine screening at 30-65 years in Copenhagen, Denmark...... (positive test results without ≥CIN3) varied between 3.3% with cytology and 14.9% with cobas. All HPV assays led to significantly more false-positive tests, whereas compared to HC2 cobas and CLART were associated with a significantly higher and APTIMA with a significantly lower proportion. Detection of CIN1...... was particularly increased for the three DNA assays. With APTIMA combined with cytological triage, about 20% more women were referred for colposcopy than with cytology screening. With the three DNA assays, the increase was ≥50%. The number of women with repeated testing was twice as high with APTIMA and almost...

  12. Comparison of three human papillomavirus DNA assays and one mRNA assay in women with abnormal cytology

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Lynge, Elsebeth; Ejegod, Ditte;

    2014-01-01

    OBJECTIVE: To compare the clinical characteristics of four human papillomavirus (HPV) assays: hybrid capture 2 (HC2), cobas, CLART, and APTIMA in Danish women with abnormal cytology. METHODS: SurePath samples from 367 consecutive women from Copenhagen, with atypical squamous cells of undetermined...

  13. Disagreement between Human Papillomavirus Assays

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Preisler, Sarah; Ejegod, Ditte Møller;

    2014-01-01

    We aimed to determine the disagreement in primary cervical screening between four human papillomavirus assays: Hybrid Capture 2, cobas, CLART, and APTIMA. Material from 5,064 SurePath samples of women participating in routine cervical screening in Copenhagen, Denmark, was tested with the four...... assays. Positive agreement between the assays was measured as the conditional probability that the results of all compared assays were positive given that at least one assay returned a positive result. Of all 5,064 samples, 1,679 (33.2%) tested positive on at least one of the assays. Among these, 41......-65 years (n = 2,881), 23% tested positive on at least one assay, and 42 to 58% of these showed positive agreement on any compared pair of the assays. While 4% of primary screening samples showed abnormal cytology, 6 to 10% were discordant on any pair of assays. A literature review corroborated our findings...

  14. Comparison of the Abbott m2000 RealTime CT Assay and the Cepheid GeneXpert CT/NG Assay to the Roche Amplicor CT Assay for Detection of Chlamydia trachomatis in Ocular Samples from Tanzania

    OpenAIRE

    Dize, Laura; West, Sheila; Williams, James A; Van Der Pol, Barbara; Quinn, Thomas C.; Gaydos, Charlotte A.

    2013-01-01

    The GeneXpert CT/NG assay (GeneXpert) and the Abbott m2000 RealTime CT (m2000) assay were compared to Amplicor for detecting ocular Chlamydia trachomatis. Discordant specimens were tested by the Aptima CT assay. The m2000 assay sensitivity was 100% (95% confidence interval [CI], 90% to 100%), and specificity was 98.46% (95% CI, 95.2% to 99.2%); GeneXpert sensitivity was 100% (95% CI, 90% to 100%), and specificity was 100% (95% CI, 98.1% to 100%). The m2000 and GeneXpert assays appear to perfo...

  15. Evaluation of Three Automated Nucleic Acid Amplification Systems for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in First-Void Urine Specimens▿

    OpenAIRE

    Levett, P N; Brandt, K.; Olenius, K.; Brown, C.; Montgomery, K.; Horsman, G. B.

    2008-01-01

    A total of 500 first-void urine specimens were tested for the presence of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acids using ProbeTec ET reagents on a Viper platform (BD Diagnostics, Mississauga, Ontario, Canada), Aptima Combo 2 reagents on a Tigris platform (Gen-Probe, Inc., San Diego, CA), and Abbott RealTime CT/NG reagents on an m2000 platform (Abbott Molecular Diagnostics, Des Plaines, IL). The performance of the three assays for detection of N. gonorrhoeae was comparable...

  16. Can We Use Antibodies to Chlamydia trachomatis as a Surveillance Tool for National Trachoma Control Programs? Results from a District Survey

    Science.gov (United States)

    West, Sheila K.; Munoz, Beatriz; Weaver, Jerusha; Mrango, Zakayo; Dize, Laura; Gaydos, Charlotte; Quinn, Thomas C.; Martin, Diana L.

    2016-01-01

    Background Trachoma is targeted for elimination by 2020. World Health Organization advises districts to undertake surveillance when follicular trachoma (TF) hamlets in Kilosa district, Tanzania, and randomly selected 50 children ages 1–9 per hamlet. The tarsal conjunctivae were graded for trachoma (TF), tested for C. trachomatis infection (Aptima Combo2 assay: Hologic, San Diego, CA), and a dried blood spot processed for antibodies to C. trachomatis pgp3 using a multiplex bead assay on a Luminex 100 platform. Principal findings The prevalence of trachoma (TF) was 0.4%, well below the hamlets, 22 had neither infection nor TF. Antibody positivity overall was low, 7.5% and increased with age from 5.2% in 1–3 year olds, to 9.3% in 7–9 year olds (p = 0.015). In 16 of the 30 hamlets, no children ages 1–3 years had antibodies to pgp3. Conclusions The antibody status of the 1–3 year olds indicates low cumulative exposure to infection during the surveillance period. Four years post MDA, there is no evidence for re-emergence of follicular trachoma. PMID:26771906

  17. Detection of Trichomonas vaginalis DNA by use of self-obtained vaginal swabs with the BD ProbeTec Qx assay on the BD Viper system.

    Science.gov (United States)

    Van Der Pol, Barbara; Williams, James A; Taylor, Stephanie N; Cammarata, Catherine L; Rivers, Charles A; Body, Barbara A; Nye, Melinda; Fuller, Deanna; Schwebke, Jane R; Barnes, Mathilda; Gaydos, Charlotte A

    2014-03-01

    Trichomonas vaginalis is the most prevalent nonviral sexually transmitted infection worldwide, and improved diagnostic methods are critical for controlling this pathogen. Diagnostic assays that can be used in conjunction with routine chlamydia/gonorrhea nucleic acid-based screening are likely to have the most impact on disease control. Here we describe the performance of the new BD T. vaginalis Qx (TVQ) amplified DNA assay, which can be performed on the automated BD Viper system. We focus on data from vaginal swab samples, since this is the specimen type routinely used for traditional trichomonas testing and the recommended specimen type for chlamydia/gonorrhea screening. Vaginal swabs were obtained from women attending sexually transmitted disease or family planning clinics at 7 sites. Patient-collected vaginal swabs were tested by the TVQ assay, and the Aptima T. vaginalis (ATV) assay was performed using clinician-collected vaginal swabs. Additional clinician-collected vaginal swabs were used for the wet mount and culture methods. Analyses included comparisons versus the patient infection status (PIS) defined by positive results with the wet mount method or culture, direct comparisons assessed with κ scores, and latent class analysis (LCA) as an unbiased estimator of test accuracy. Data from 838 women, 116 of whom were infected with T. vaginalis, were analyzed. The TVQ assay sensitivity and specificity estimates based on the PIS were 98.3% and 99.0%, respectively. The TVQ assay was similar to the ATV assay (κ=0.938) in direct analysis. LCA estimated the TVQ sensitivity and specificity as 98.3 and 99.6%, respectively. The TVQ assay performed well using self-collected vaginal swabs, the optimal sample type, as recommended by the CDC for chlamydia/gonorrhea screening among women. PMID:24391200

  18. Angiogenesis Assays.

    Science.gov (United States)

    Nambiar, Dhanya K; Kujur, Praveen K; Singh, Rana P

    2016-01-01

    Neoangiogenesis constitutes one of the first steps of tumor progression beyond a critical size of tumor growth, which supplies a dormant mass of cancerous cells with the required nutrient supply and gaseous exchange through blood vessels essentially needed for their sustained and aggressive growth. In order to understand any biological process, it becomes imperative that we use models, which could mimic the actual biological system as closely as possible. Hence, finding the most appropriate model is always a vital part of any experimental design. Angiogenesis research has also been much affected due to lack of simple, reliable, and relevant models which could be easily quantitated. The angiogenesis models have been used extensively for studying the action of various molecules for agonist or antagonistic behaviour and associated mechanisms. Here, we have described two protocols or models which have been popularly utilized for studying angiogenic parameters. Rat aortic ring assay tends to bridge the gap between in vitro and in vivo models. The chorioallantoic membrane (CAM) assay is one of the most utilized in vivo model system for angiogenesis-related studies. The CAM is highly vascularized tissue of the avian embryo and serves as a good model to study the effects of various test compounds on neoangiogenesis. PMID:26608294

  19. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  20. Radioreceptor opioid assay

    International Nuclear Information System (INIS)

    A radioreceptor assay is described for assaying opioid drugs in biological fluids. The method enables the assay of total opioid activity, being specific for opioids as a class but lacking specificity within the class. A radio-iodinated opioid and the liquid test sample are incubated with an opiate receptor material. The percentage inhibition of the binding of the radio-iodinated compound to the opiate receptor is calculated and the opioid activity of the test liquid determined from a standard curve. Examples of preparing radio-iodinated opioids and assaying opioid activity are given. A test kit for the assay is described. Compared to other methods, this assay is cheap, easy and rapid. (U.K.)

  1. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  2. CPTAC Assay Portal: a repository of targeted proteomic assays

    Energy Technology Data Exchange (ETDEWEB)

    Whiteaker, Jeffrey R.; Halusa, Goran; Hoofnagle, Andrew N.; Sharma, Vagisha; MacLean, Brendan; Yan, Ping; Wrobel, John; Kennedy, Jacob; Mani, DR; Zimmerman, Lisa J.; Meyer, Matthew R.; Mesri, Mehdi; Rodriguez, Henry; Abbateillo, Susan E.; Boja, Emily; Carr, Steven A.; Chan, Daniel W.; Chen, Xian; Chen, Jing; Davies, Sherri; Ellis, Matthew; Fenyo, David; Hiltket, Tara; Ketchum, Karen; Kinsinger, Christopher; Kuhn, Eric; Liebler, Daniel; Lin, De; Liu, Tao; Loss, Michael; MacCoss, Michael; Qian, Weijun; Rivers, Robert; Rodland, Karin D.; Ruggles, Kelly; Scott, Mitchell; Smith, Richard D.; Thomas, Stefani N.; Townsend, Reid; Whiteley, Gordon; Wu, Chaochao; Zhang, Hui; Zhang, Zhen; Paulovich, Amanda G.

    2014-06-27

    To address these issues, the Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as a public repository of well-characterized quantitative, MS-based, targeted proteomic assays. The purpose of the CPTAC Assay Portal is to facilitate widespread adoption of targeted MS assays by disseminating SOPs, reagents, and assay characterization data for highly characterized assays. A primary aim of the NCI-supported portal is to bring together clinicians or biologists and analytical chemists to answer hypothesis-driven questions using targeted, MS-based assays. Assay content is easily accessed through queries and filters, enabling investigators to find assays to proteins relevant to their areas of interest. Detailed characterization data are available for each assay, enabling researchers to evaluate assay performance prior to launching the assay in their own laboratory.

  3. Transgenic Animal Mutation Assays

    Institute of Scientific and Technical Information of China (English)

    Tao Chen; Ph.D.D.A.B.T.

    2005-01-01

    @@ The novel transgenic mouse and rat mutation assays have provided a tool for analyzing in vivo mutation in any tissue, thus permitting the direct comparison of cancer incidence with mutant frequency.

  4. Lateral flow assays.

    Science.gov (United States)

    Koczula, Katarzyna M; Gallotta, Andrea

    2016-06-30

    Lateral flow assays (LFAs) are the technology behind low-cost, simple, rapid and portable detection devices popular in biomedicine, agriculture, food and environmental sciences. This review presents an overview of the principle of the method and the critical components of the assay, focusing on lateral flow immunoassays. This type of assay has recently attracted considerable interest because of its potential to provide instantaneous diagnosis directly to patients. The range and interpretation of results and parameters used for evaluation of the assay will also be discussed. The main advantages and disadvantages of LFAs will be summarized and relevant future improvements to testing devices and strategies will be proposed. Finally, the major recent advances and future diagnostic applications in the LFA field will be explored. PMID:27365041

  5. New Rapid Spore Assay

    Science.gov (United States)

    Kminek, Gerhard; Conley, Catharine

    2012-07-01

    The presentation will detail approved Planetary Protection specifications for the Rapid Spore Assay for spacecraft components and subsystems. Outlined will be the research and studies on which the specifications were based. The research, funded by ESA and NASA/JPL, was conducted over a period of two years and was followed by limited cleanroom studies to assess the feasibility of this assay during spacecraft assembly.

  6. Assay method and compositions

    International Nuclear Information System (INIS)

    Methods are described for measuring catecholamine levels in human and animal body fluids and tissues using the catechol-O-methyl-transferase (COMT) radioassay. The assay involves incubating the biological sample with COMT and the tritiated methyl donor, S-adenosyl-L-methionine(3H)-methyl. The O-methylated (3H) epinephrine and/or norepinephrine are extracted and oxidised to vanillin-3H which in turn is extracted and its radioactivity counted. When analysing dopamine levels the assay is extended by vanillin-3H and raising the pH of the aqueous periodate phase from which O-methylated (3H) dopamine is extracted and counted. The assay may be modified depending on whether measurements of undifferentiated total endogenous catecholamine levels or differential analyses of the catecholamine levels are being performed. The sensitivity of the assay can be as low as 5 picograms for norepinephrine and epinephrine and 12 picograms for dopamine. The assemblance of the essential components of the assay into a kit for use in laboratories is also described. (U.K.)

  7. Rover waste assay system

    Energy Technology Data Exchange (ETDEWEB)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched {sup 235}U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for {sup 137}Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs.

  8. Rover waste assay system

    International Nuclear Information System (INIS)

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched 235U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for 137Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs

  9. Interpreting coagulation assays.

    Science.gov (United States)

    Green, David

    2010-09-01

    The interpretation of coagulation assays requires knowledge of the principal clotting pathways. The activated partial thromboplastin time is sensitive to all hemostatic factors except FVII, whereas the prothrombin time reflects levels of prothrombin and FV, FVII, and FX. Using the two tests in concert is helpful in identifying hemophilia, the coagulopathy of liver disease, and disseminated intravascular coagulation. In addition, the activated partial thromboplastin time and prothrombin time are used for monitoring anticoagulant therapy with heparin and warfarin, respectively. Measurement of D-dimer is informative in patients suspected of having thrombotic disorders and determining the risk of thrombosis recurrence. Mixing tests distinguish clotting factor deficiencies from circulating anticoagulants such as heparin, the lupus anticoagulant, and antibodies directed against specific clotting factors. The modified Bethesda assay detects and provides an indication of the strength of FVIII inhibitors. However, interpreting the results of coagulation assays is not always straightforward, and expert consultation is occasionally required to resolve difficult clinical situations. PMID:20855988

  10. Neutral Comet Assay

    OpenAIRE

    2013-01-01

    The Comet assay (or Single Cell Gel Electrophoresis assay) is a sensitive technique to detect DNA damage at the level of an individual cell. This technique is based on micro-electrophoresis of cells DNA content. Briefly, cells are embedded in agarose, lysed and submitted to an electric field, before the staining step with a fluorescent DNA binding dye. Damaged DNA (charged DNA) migrates in this field, forming the tail of a “comet”, while undamaged DNA remained in the head of the “comet”. The ...

  11. Lateral flow strip assay

    Science.gov (United States)

    Miles, Robin R.; Benett, William J.; Coleman, Matthew A.; Pearson, Francesca S.; Nasarabadi, Shanavaz L.

    2011-03-08

    A lateral flow strip assay apparatus comprising a housing; a lateral flow strip in the housing, the lateral flow strip having a receiving portion; a sample collection unit; and a reagent reservoir. Saliva and/or buccal cells are collected from an individual using the sample collection unit. The sample collection unit is immersed in the reagent reservoir. The tip of the lateral flow strip is immersed in the reservoir and the reagent/sample mixture wicks up into the lateral flow strip to perform the assay.

  12. Automated phantom assay system

    International Nuclear Information System (INIS)

    This paper describes an automated phantom assay system developed for assaying phantoms spiked with minute quantities of radionuclides. The system includes a computer-controlled linear-translation table that positions the phantom at exact distances from a spectrometer. A multichannel analyzer (MCA) interfaces with a computer to collect gamma spectral data. Signals transmitted between the controller and MCA synchronize data collection and phantom positioning. Measured data are then stored on disk for subsequent analysis. The automated system allows continuous unattended operation and ensures reproducible results

  13. Lateral flow assays

    NARCIS (Netherlands)

    Posthuma-Trumpie, G.A.; Amerongen, van A.

    2012-01-01

    A simple version of immunochemical-based methods is the Lateral Flow Assay (LFA). It is a dry chemistry technique (reagents are included); the fluid from the sample runs through a porous membrane (often nitrocellulose) by capillary force. Typically the membrane is cut as a strip of 0.5*5 cm. In most

  14. Hyaluronic Acid Assays

    DEFF Research Database (Denmark)

    Itenov, Theis Skovsgaard; Kirkby, Nikolai S; Bestle, Morten H;

    2015-01-01

    BACKGROUD: Hyaluronic acid (HA) is proposed as a marker of functional liver capacity. The aim of the present study was to compare a new turbidimetric assay for measuring HA with the current standard method. METHODS: HA was measured by a particle-enhanced turbidimetric immunoassay (PETIA) and enzyme...

  15. Instrument for assaying radiation

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, Jody Rustyn; Farfan, Eduardo B.

    2016-03-22

    An instrument for assaying radiation includes a flat panel detector having a first side opposed to a second side. A collimated aperture covers at least a portion of the first side of the flat panel detector. At least one of a display screen or a radiation shield may cover at least a portion of the second side of the flat panel detector.

  16. Radon assay for SNO+

    International Nuclear Information System (INIS)

    The SNO+ experiment will study neutrinos while located 6,800 feet below the surface of the earth at SNOLAB. Though shielded from surface backgrounds, emanation of radon radioisotopes from the surrounding rock leads to back-grounds. The characteristic decay of radon and its daughters allows for an alpha detection technique to count the amount of Rn-222 atoms collected. Traps can collect Rn-222 from various positions and materials, including an assay skid that will collect Rn-222 from the organic liquid scintillator used to detect interactions within SNO+

  17. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is a......, when operatively connected, one or more chambers (21) comprising the chemical entities (41), the inlet(s) (5) and outlet(s) (6) and chambers (21) being in fluid connection. The device further comprise means for providing differing chemical conditions in each chamber (21)....

  18. Growth cone collapse assay.

    Science.gov (United States)

    Cook, Geoffrey M W; Jareonsettasin, Prem; Keynes, Roger J

    2014-01-01

    The growth cone collapse assay has proved invaluable in detecting and purifying axonal repellents. Glycoproteins/proteins present in detergent extracts of biological tissues are incorporated into liposomes, added to growth cones in culture and changes in morphology are then assessed. Alternatively purified or recombinant molecules in aqueous solution may be added directly to the cultures. In both cases after a defined period of time (up to 1 h), the cultures are fixed and then assessed by inverted phase contrast microscopy for the percentage of growth cones showing a collapsed profile with loss of flattened morphology, filopodia, and lamellipodia.

  19. Radon assay for SNO+

    Energy Technology Data Exchange (ETDEWEB)

    Rumleskie, Janet [Laurentian University, Greater Sudbury, Ontario (Canada)

    2015-12-31

    The SNO+ experiment will study neutrinos while located 6,800 feet below the surface of the earth at SNOLAB. Though shielded from surface backgrounds, emanation of radon radioisotopes from the surrounding rock leads to back-grounds. The characteristic decay of radon and its daughters allows for an alpha detection technique to count the amount of Rn-222 atoms collected. Traps can collect Rn-222 from various positions and materials, including an assay skid that will collect Rn-222 from the organic liquid scintillator used to detect interactions within SNO+.

  20. PathogenMip Assay: A Multiplex Pathogen Detection Assay

    OpenAIRE

    Akhras, Michael S.; Sreedevi Thiyagarajan; Villablanca, Andrea C.; Davis, Ronald W; Pål Nyrén; Nader Pourmand

    2007-01-01

    The Molecular Inversion Probe (MIP) assay has been previously applied to a large-scale human SNP detection. Here we describe the PathogenMip Assay, a complete protocol for probe production and applied approaches to pathogen detection. We have demonstrated the utility of this assay with an initial set of 24 probes targeting the most clinically relevant HPV genotypes associated with cervical cancer progression. Probe construction was based on a novel, cost-effective, ligase-based protocol. The ...

  1. Practical assay issues with the PERT/PBRT assay: a highly sensitive reverse transcriptase assay.

    Science.gov (United States)

    Chang, A; Dusing, S

    2006-01-01

    Product safety testing for retroviruses can be achieved by a panel of screening assays, including electron microscopy, viral gene specific PCRs, virus propagation, and detection of reverse transciptase activity. The application of PCR-based reverse transcriptase assays (PERT) that are approximately a million-fold more sensitive than conventional nucleotide incorporation assays in the testing of biologicals is described. Use of PERT assays can be applied to three areas: (i) screening for adventitious retrovirus contamination; (ii) detecting and quantifying endogenous viral particle load and (iii) monitoring levels of infectious retrovirus generation in cell lines that contain endogenous retroviruses.

  2. From Antenna to Assay

    Science.gov (United States)

    Moore, Evan G.; Samuel, Amanda P. S.; Raymond, Kenneth N.

    2009-01-01

    Conspectus Ligand-sensitized, luminescent lanthanide(III) complexes are of considerable importance because their unique photophysical properties (microsecond to millisecond lifetimes, characteristic and narrow emission bands, and large Stokes shifts) make them well suited as labels in fluorescence-based bioassays. The long-lived emission of lanthanide(III) cations can be temporally resolved from scattered light and background fluorescence to vastly enhance measurement sensitivity. One challenge in this field is the design of sensitizing ligands that provide highly emissive complexes with sufficient stability and aqueous solubility for practical applications. In this Account, we give an overview of some of the general properties of the trivalent lanthanides and follow with a summary of advances made in our laboratory in the development of highly luminescent Tb(III) and Eu(III) complexes for applications in biotechnology. A focus of our research has been the optimization of these compounds as potential commercial agents for use in Homogeneous Time-Resolved Fluorescence (HTRF) technology. Our approach involves developing high-stability octadentate Tb(III) and Eu(III) complexes that rely on all-oxygen donor atoms and using multi-chromophore chelates to increase molar absorptivity; earlier examples utilized a single pendant chromophore (that is, a single “antenna”). Ligands based on 2-hydroxyisophthalamide (IAM) provide exceptionally emissive Tb(III) complexes with quantum yield values up to ∼60% that are stable at the nanomolar concentrations required for commercial assays. Through synthetic modification of the IAM chromophore and time-dependent density functional theory (TD-DFT) calculations, we have developed a method to predict absorption and emission properties of these chromophores as a tool to guide ligand design. Additionally, we have investigated chiral IAM ligands that yield Tb(III) complexes possessing both high quantum yield values and strong

  3. New Application of the Comet Assay: Chromosome–Comet Assay

    OpenAIRE

    Cortés-Gutiérrez, Elva I.; DÁVILA-RODRÍGUEZ, MARTHA I.; Fernández, José Luís; López-Fernández, Carmen; Gosálbez, Altea; Gosálvez, Jaime

    2011-01-01

    The comet assay is a well-established, simple, versatile, visual, rapid, and sensitive tool used extensively to assess DNA damage and DNA repair quantitatively and qualitatively in single cells. The comet assay is most frequently used to analyze white blood cells or lymphocytes in human biomonitoring studies, although other cell types have been examined, including buccal, nasal, epithelial, and placental cells and even spermatozoa. This study was conducted to design a protocol that can be use...

  4. Comparison of chemosensitivity tests: clonogenic assay versus MTT assay.

    Directory of Open Access Journals (Sweden)

    Kawada K

    2002-06-01

    Full Text Available When the development of chemotherapeutic agents reaches the clinical trial stage, it is necessary to perform drug sensitivity tests quickly in order to select the most promising agents for the treatment of cancer. In order to assess the possibility of using the 3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide (MTT assay as a substitute for the human tumor clonogenic assay (HTCA, we evaluated the correlation between the results obtained by these 2 assays in 5 human lung cancer cell lines. The correlation coefficient between the results of the HTCA and the MTT assay was 0.673, indicating a relatively good correlation. The correlation was most prominent in platinum analogues (r = 0.939 and good in anthracyclines/anthracenedione (r = 0.611. However, no significant correlation was observed in vinca alkaloids, etoposide, irinotecan, SN-38 (an active metabolite of irinotecan, and rhizoxin. The results of the MTT assay showed a high degree of correlation with those of the HTCA in predicting the sensitivity of cancer cell lines to platinum analogues, and anthracyclines/anthracenedione. These results suggest that the MTT assay may be more convenient and quickly performed than the HTCA and can replace HTCA in evaluating the effects of anticancer agents, especially the platinum analogues and anthracyclines/anthracenedione.

  5. Calorimetric assay of minor actinides

    Energy Technology Data Exchange (ETDEWEB)

    Rudy, C.; Bracken, D.; Cremers, T.; Foster, L.A.; Ensslin, N.

    1996-12-31

    This paper reviews the principles of calorimetric assay and evaluates its potential application to the minor actinides (U-232-4, Am-241, Am- 243, Cm-245, Np-237). We conclude that calorimetry and high- resolution gamma-ray isotopic analysis can be used for the assay of minor actinides by adapting existing methodologies for Pu/Am-241 mixtures. In some cases, mixtures of special nuclear materials and minor actinides may require the development of new methodologies that involve a combination of destructive and nondestructive assay techniques.

  6. Calorimetric assay of minor actinides

    International Nuclear Information System (INIS)

    This paper reviews the principles of calorimetric assay and evaluates its potential application to the minor actinides (U-232-4, Am-241, Am- 243, Cm-245, Np-237). We conclude that calorimetry and high- resolution gamma-ray isotopic analysis can be used for the assay of minor actinides by adapting existing methodologies for Pu/Am-241 mixtures. In some cases, mixtures of special nuclear materials and minor actinides may require the development of new methodologies that involve a combination of destructive and nondestructive assay techniques

  7. Time-Resolved Fluorescence Assays.

    Science.gov (United States)

    Ma, Chen-Ting; Sergienko, Eduard A

    2016-01-01

    Fluorescence-based detection techniques are popular in high throughput screening due to sensitivity and cost-effectiveness. Four commonly used techniques exist, each with distinct characteristics. Fluorescence intensity assays are the simplest to run, but suffer the most from signal interference. Fluorescence polarization assays show less interference from the compounds or the instrument, but require a design that results in change of fluorophore-containing moiety size and usually have narrow assay signal window. Fluorescence resonance energy transfer (FRET) is commonly used for detecting protein-protein interactions and is constrained not by the sizes of binding partners, but rather by the distance between fluorophores. Time-resolved fluorescence resonance energy transfer (TR-FRET), an advanced modification of FRET approach utilizes special fluorophores with long-lived fluorescence and earns its place near the top of fluorescent techniques list by its performance and robustness, characterized by larger assay window and minimized compound spectral interference. TR-FRET technology can be applied in biochemical or cell-based in vitro assays with ease. It is commonly used to detect modulation of protein-protein interactions and in detection of products of biochemical reactions and cellular activities. PMID:27316992

  8. Barcoded microchips for biomolecular assays.

    Science.gov (United States)

    Zhang, Yi; Sun, Jiashu; Zou, Yu; Chen, Wenwen; Zhang, Wei; Xi, Jianzhong Jeff; Jiang, Xingyu

    2015-01-20

    Multiplexed assay of analytes is of great importance for clinical diagnostics and other analytical applications. Barcode-based bioassays with the ability to encode and decode may realize this goal in a straightforward and consistent manner. We present here a microfluidic barcoded chip containing several sets of microchannels with different widths, imitating the commonly used barcode. A single barcoded microchip can carry out tens of individual protein/nucleic acid assays (encode) and immediately yield all assay results by a portable barcode reader or a smartphone (decode). The applicability of a barcoded microchip is demonstrated by human immunodeficiency virus (HIV) immunoassays for simultaneous detection of three targets (anti-gp41 antibody, anti-gp120 antibody, and anti-gp36 antibody) from six human serum samples. We can also determine seven pathogen-specific oligonucleotides by a single chip containing both positive and negative controls.

  9. Chromosome aberration assays in Allium

    Energy Technology Data Exchange (ETDEWEB)

    Grant, W.F.

    1982-01-01

    The common onion (Allium cepa) is an excellent plant for the assay of chromosome aberrations after chemical treatment. Other species of Allium (A. cepa var. proliferum, A. carinatum, A. fistulosum and A. sativum) have also been used but to a much lesser extent. Protocols have been given for using root tips from either bulbs or seeds of Allium cepa to study the cytological end-points, such as chromosome breaks and exchanges, which follow the testing of chemicals in somatic cells. It is considered that both mitotic and meiotic end-points should be used to a greater extent in assaying the cytogenetic effects of a chemical. From a literature survey, 148 chemicals are tabulated that have been assayed in 164 Allium tests for their clastogenic effect. Of the 164 assays which have been carried out, 75 are reported as giving a positive reaction, 49 positive and with a dose response, 1 positive and temperature-related, 9 borderline positive, and 30 negative; 76% of the chemicals gave a definite positive response. It is proposed that the Allium test be included among those tests routinely used for assessing chromosomal damage induced by chemicals.

  10. Bacterial mutagenicity assays: test methods.

    Science.gov (United States)

    Gatehouse, David

    2012-01-01

    The most widely used assays for detecting chemically induced gene mutations are those employing bacteria. The plate incorporation assay using various Salmonella typhimurium LT2 and E. coli WP2 strains is a short-term bacterial reverse mutation assay specifically designed to detect a wide range of chemical substances capable of causing DNA damage leading to gene mutations. The test is used worldwide as an initial screen to determine the mutagenic potential of new chemicals and drugs.The test uses several strains of S. typhimurium which carry different mutations in various genes of the histidine operon, and E. coli which carry the same AT base pair at the critical mutation site within the trpE gene. These mutations act as hot spots for mutagens that cause DNA damage via different mechanisms. When these auxotrophic bacterial strains are grown on a minimal media agar plates containing a trace of the required amino-acid (histidine or tryptophan), only those bacteria that revert to amino-acid independence (His(+) or Tryp(+)) will grow to form visible colonies. The number of spontaneously induced revertant colonies per plate is relatively constant. However, when a mutagen is added to the plate, the number of revertant colonies per plate is increased, usually in a dose-related manner.This chapter provides detailed procedures for performing the test in the presence and absence of a metabolic activation system (S9-mix), including advice on specific assay variations and any technical problems. PMID:22147566

  11. Assays for B lymphocyte function.

    Science.gov (United States)

    Bondada, Subbarao; Robertson, Darrell A

    2003-11-01

    This unit describes the antigenic stimulation of in vitro antibody production by B cells and the subsequent measurement of secreted antibodies. The first basic protocol is a generalized system for inducing in vitro antibody production and can accommodate various types of antigens under study. Secreted antibodies can then be measured with an enzyme-linked immunosorbent assay (ELISA) or other soluble-antibody detection systems. Alternatively, the number of antibody-producing cells can be quantified by plaque-forming cell (PFC) assays presented in this unit: the Cunningham-Szenberg and the Jerne-Nordin techniques. Both methods employ specially prepared slide chambers, described here, in which the antibody-producing B cells are mixed with complement and indicator sheep red blood cells (SRBC), or with trinitrophenol-modified SRBC (TNP-SRBC), with subsequent lysis and counting of plaques. Because IgM antibodies fix complement efficiently, whereas IgG and IgA antibodies do not, unmodified PFC assays measure only IgM antibodies. The assay can be modified, however, to measure all classes of antibodies or to enumerate total immunoglobulin-secreting B cells, as described in alternate protocols. Yet another method of measuring the number of antibody-producing B cells (in a class-specific fashion) is to use the ELISPOT technique described in UNIT 7.14. The resting B cells used in these procedures are prepared as described in the final support protocols for Percoll gradient centrifugation. PMID:18432909

  12. Controlling variation in the comet assay

    OpenAIRE

    Collins, Andrew R; El Yamani, Naouale; Lorenzo, Yolanda; Shaposhnikov, Sergey; Brunborg, Gunnar; Azqueta, Amaya

    2014-01-01

    Variability of the comet assay is a serious issue, whether it occurs from experiment to experiment in the same laboratory, or between different laboratories analysing identical samples. Do we have to live with high variability, just because the comet assay is a biological assay rather than analytical chemistry? Numerous attempts have been made to limit variability by standardizing the assay protocol, and the critical steps in the assay have been identified; agarose concentration, duration of ...

  13. The skin-blanching assay.

    Science.gov (United States)

    Smit, P; Neumann, H A M; Thio, H B

    2012-10-01

    The skin-blanching assay is used for the determination and bioequivalence of dermatologic glucocorticoids (GCs). The exact mechanism of the production of blanching is not fully understood, but it is considered that local vasoconstriction of the skin microvasculature and the consequent blood-flow reduction cause this phenomenon. Several factors influence skin blanching, including drug concentration, duration of application, nature of vehicle, occlusion, posture and location. The intensity of vasoconstriction can be measured in several ways: visual or quantitative methods, such as reflectance spectroscopy, thermography, laser Doppler velocimetry and chromametry. In literature, contradicting results in the correlation of the skin-blanching assay with different tests to determine GC sensitivity have been reported, limiting its clinical usefulness.

  14. Comet Assay in Cancer Chemoprevention.

    Science.gov (United States)

    Santoro, Raffaela; Ferraiuolo, Maria; Morgano, Gian Paolo; Muti, Paola; Strano, Sabrina

    2016-01-01

    The comet assay can be useful in monitoring DNA damage in single cells caused by exposure to genotoxic agents, such as those causing air, water, and soil pollution (e.g., pesticides, dioxins, electromagnetic fields) and chemo- and radiotherapy in cancer patients, or in the assessment of genoprotective effects of chemopreventive molecules. Therefore, it has particular importance in the fields of pharmacology and toxicology, and in both environmental and human biomonitoring. It allows the detection of single strand breaks as well as double-strand breaks and can be used in both normal and cancer cells. Here we describe the alkali method for comet assay, which allows to detect both single- and double-strand DNA breaks. PMID:26608293

  15. Nondestructive assay of sale materials

    International Nuclear Information System (INIS)

    This paper covers three primary areas: (1) reasons for performing nondestructive assay on SALE materials; (2) techniques used; and (3) discussion of investigators' revised results. The study shows that nondestructive calorimetric assay of plutonium offers a viable alternative to traditional wet chemical techniques. For these samples, the precision ranged from 0.4 to 0.6% with biases less than 0.2%. Thus, for those materials where sampling errors are the predominant source of uncertainty, this technique can provide improved accuracy and precision while saving time and money as well as reducing the amount of liquid wastes to be handled. In addition, high resolution gamma-ray spectroscopy measurements of solids can provide isotopic analysis data in a cost effective and timely manner. The timeliness of the method can be especially useful to the plant operator for production control and quality control measurements

  16. Protein binding assay for hyaluronate

    Energy Technology Data Exchange (ETDEWEB)

    Lacy, B.E.; Underhill, C.B.

    1986-11-01

    A relatively quick and simple assay for hyaluronate was developed using the specific binding protein, hyaluronectin. The hyaluronectin was obtained by homogenizing the brains of Sprague-Dawley rats, and then centrifuging the homogenate. The resulting supernatant was used as a source of crude hyaluronectin. In the binding assay, the hyaluronectin was mixed with (/sup 3/H)hyaluronate, followed by an equal volume of saturated (NH/sub 4/)/sub 2/SO/sub 4/, which precipitated the hyaluronectin and any (/sup 3/H)hyaluronate associated with it, but left free (/sup 3/H)hyaluronate in solution. The mixture was then centrifuged, and the amount of bound (/sup 3/H)hyaluronate in the precipitate was determined. Using this assay, the authors found that hyaluronectin specifically bound hyaluronate, since other glycosaminoglycans failed to compete for the binding protein. In addition, the interaction between hyaluronectin and hyaluronate was of relatively high affinity, and the size of the hyaluronate did not appear to substantially alter the amount of binding. To determine the amount of hyaluronate in an unknown sample, they used a competition assay in which the binding of a set amount of (/sup 3/H)hyaluronate was blocked by the addition of unlabeled hyaluronate. By comparing the degree of competition of the unknown samples with that of known amounts of hyaluronate, it was possible to determine the amount of hyaluronate in the unknowns. They have found that this method is sensitive to 1 ..mu..g or less of hyaluronate, and is unaffected by the presence of proteins.

  17. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    Directory of Open Access Journals (Sweden)

    Carina Ladeira

    2015-06-01

    The use of the CBMN assay in in vitro genetic toxicology testing is well established and in fact it has become an accepted standard method to assess the genotoxic hazard of chemicals which led to the development of a special guideline by the Organization for Economic Cooperation and Development (OECD, the OECD 487 guideline (Kirsch-Volders et al., 2014. The CBMN assay is an effective tool for the study of cellular and nuclear dysfunction caused by in vitro or in vivo aging, micronutrient deficiency or excess, genotoxins exposure and genetic defects in genome maintenance. It is also fruitful in the emerging fields of nutrigenomics and toxicogenomics and their combinations, as it becomes increasingly clear that nutrient status also impacts on sensitivity to exogenous genotoxins (Fenech, 2005, 2007. Many results obtained by this assay indicate the potential predictive value of the CBMN assay with respect to cancer risk and validate its use as a test for detecting nutritional, environmental and genetic factors that are potentially carcinogenic. Also it is used by pharmaceutical industry, human biomonitoring of genotoxic exposures and its increasing application in preventive medicine and nutrition and the increased investment in the automation of the CBMN assay are indicative of the increasing importance of this test (Fenech, 2007. The comet assay or single-cell gel electrophoresis (SCGE is a simple, sensitive method for detecting DNA-strand breaks. Cells embedded in agarose on a microscope slide are lysed with detergent and 2.5 M NaCl and fresh Triton X-100 to remove membranes and soluble cell constituents, including most histones, leaving the DNA, still supercoiled and attached to a nuclear matrix, as a nucleoid. A break in one strand of a DNA loop is enough to release the supercoiling, and during electrophoresis the relaxed loops are able to extend towards the anode (Fairbairn et al., 1995; Collins et al., 1997; Moller et al., 2000; Azqueta et al., 2009; Collins

  18. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    OpenAIRE

    Carina Ladeira; Susana Viegas; Gomes, Manuel C.

    2015-01-01

    The cytokinesis-block micronucleus cytome (CBMN) assay is a comprehensive system for measuring DNA damage; cytostasis and cytotoxicity-DNA damage events are scored specifically in once-divided binucleated cells. The endpoints possible to be measured are micronuclei (MN), a biomarker of chromosome breakage and/or whole chromosome loss, nucleoplasmic bridges (NPB), a biomarker of DNA misrepair and/or telomere end-fusions, and nuclear buds (NBUD), a biomarker of elimination of amplified DNA and/...

  19. Serum indices: managing assay interference.

    Science.gov (United States)

    Farrell, Christopher-John L; Carter, Andrew C

    2016-09-01

    Clinical laboratories frequently encounter samples showing significant haemolysis, icterus or lipaemia. Technical advances, utilizing spectrophotometric measurements on automated chemistry analysers, allow rapid and accurate identification of such samples. However, accurate quantification of haemolysis, icterus and lipaemia interference is of limited value if laboratories do not set rational alert limits, based on sound interference testing experiments. Furthermore, in the context of increasing consolidation of laboratories and the formation of laboratory networks, there is an increasing requirement for harmonization of the handling of haemolysis, icterus and lipaemia-affected samples across different analytical platforms. Harmonization may be best achieved by considering both the analytical aspects of index measurement and the possible variations in the effects of haemolysis, icterus and lipaemia interferences on assays from different manufacturers. Initial verification studies, followed up with ongoing quality control testing, can help a laboratory ensure the accuracy of haemolysis, icterus and lipaemia index results, as well as assist in managing any biases in index results from analysers from different manufacturers. Similarities, and variations, in the effect of haemolysis, icterus and lipaemia interference in assays from different manufacturers can often be predicted from the mechanism of interference. Nevertheless, interference testing is required to confirm expected similarities or to quantify differences. It is important that laboratories are familiar with a number of interference testing protocols and the particular strengths and weaknesses of each. A rigorous approach to all aspects of haemolysis, icterus and lipaemia interference testing allows the analytical progress in index measurement to be translated into improved patient care. PMID:27147624

  20. SNO+ Scintillator Purification and Assay

    Science.gov (United States)

    Ford, R.; Chen, M.; Chkvorets, O.; Hallman, D.; Vázquez-Jáuregui, E.

    2011-04-01

    We describe the R&D on the scintillator purification and assay methods and technology for the SNO+ neutrino and double-beta decay experiment. The SNO+ experiment is a replacement of the SNO heavy water with liquid scintillator comprised of 2 g/L PPO in linear alkylbenzene (LAB). During filling the LAB will be transported underground by rail car and purified by multi-stage distillation and steam stripping at a flow rate of 19 LPM. While the detector is operational the scintillator can be recirculated at 150 LPM (full detector volume in 4 days) to provide repurification as necessary by either water extraction (for Ra, K, Bi) or by functional metal scavenger columns (for Pb, Ra, Bi, Ac, Th) followed by steam stripping to remove noble gases and oxygen (Rn, O2, Kr, Ar). The metal scavenger columns also provide a method for scintillator assay for ex-situ measurement of the U and Th chain radioactivity. We have developed "natural" radioactive spikes of Pb and Ra in LAB and use these for purification testing. Lastly, we present the planned operating modes and purification strategies and the plant specifications and design.

  1. Proteasome Assay in Cell Lysates

    Science.gov (United States)

    Maher, Pamela

    2016-01-01

    The ubiquitin-proteasome system (UPS) mediates the majority of the proteolysis seen in the cytoplasm and nucleus of mammalian cells. As such it plays an important role in the regulation of a variety of physiological and pathophysiological processes including tumorigenesis, inflammation and cell death (Ciechanover, 2005; Kisselev and Goldberg, 2001). A number of recent studies have shown that proteasome activity is decreased in a variety of neurological disorders including Parkinson's disease, Alzheimer's disease, amyotrophic lateral sclerosis and stroke as well as during normal aging (Chung et al., 2001; Ciechanover and Brundin, 2003; Betarbet et al., 2005). This decrease in proteasome activity is thought to play a critical role in the accumulation of abnormal and oxidized proteins. Protein clearance by the UPS involves two sequential reactions. The first is the tagging of protein lysine residues with ubiquitin (Ub) and the second is the subsequent degradation of the tagged proteins by the proteasome. We herein describe an assay for the second of these two reactions (Valera et al., 2013). This assay uses fluorogenic substrates for each of the three activities of the proteasome: chymotrypsin-like activity, trypsin-like activity and caspase-like activity. Cleavage of the fluorophore from the substrate by the proteasome results in fluorescence that can be detected with a fluorescent plate reader.

  2. The chemistry behind antioxidant capacity assays.

    Science.gov (United States)

    Huang, Dejian; Ou, Boxin; Prior, Ronald L

    2005-03-23

    This review summarizes the multifaceted aspects of antioxidants and the basic kinetic models of inhibited autoxidation and analyzes the chemical principles of antioxidant capacity assays. Depending upon the reactions involved, these assays can roughly be classified into two types: assays based on hydrogen atom transfer (HAT) reactions and assays based on electron transfer (ET). The majority of HAT-based assays apply a competitive reaction scheme, in which antioxidant and substrate compete for thermally generated peroxyl radicals through the decomposition of azo compounds. These assays include inhibition of induced low-density lipoprotein autoxidation, oxygen radical absorbance capacity (ORAC), total radical trapping antioxidant parameter (TRAP), and crocin bleaching assays. ET-based assays measure the capacity of an antioxidant in the reduction of an oxidant, which changes color when reduced. The degree of color change is correlated with the sample's antioxidant concentrations. ET-based assays include the total phenols assay by Folin-Ciocalteu reagent (FCR), Trolox equivalence antioxidant capacity (TEAC), ferric ion reducing antioxidant power (FRAP), "total antioxidant potential" assay using a Cu(II) complex as an oxidant, and DPPH. In addition, other assays intended to measure a sample's scavenging capacity of biologically relevant oxidants such as singlet oxygen, superoxide anion, peroxynitrite, and hydroxyl radical are also summarized. On the basis of this analysis, it is suggested that the total phenols assay by FCR be used to quantify an antioxidant's reducing capacity and the ORAC assay to quantify peroxyl radical scavenging capacity. To comprehensively study different aspects of antioxidants, validated and specific assays are needed in addition to these two commonly accepted assays. PMID:15769103

  3. 21 CFR 864.7525 - Heparin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Heparin assay. 864.7525 Section 864.7525 Food and... HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7525 Heparin assay. (a) Identification. A heparin assay is a device used to determine the level of the anticoagulant heparin in the...

  4. Multicentre comparison of a diagnostic assay

    DEFF Research Database (Denmark)

    Waters, Patrick; Reindl, Markus; Saiz, Albert;

    2016-01-01

    ) assays in neuromyelitis optica spectrum disorders (NMOSD). METHODS: Coded samples from patients with neuromyelitis optica (NMO) or NMOSD (101) and controls (92) were tested at 15 European diagnostic centres using 21 assays including live (n=3) or fixed cell-based assays (n=10), flow cytometry (n=4...

  5. 21 CFR 864.7490 - Sulfhemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sulfhemoglobin assay. 864.7490 Section 864.7490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... assay. (a) Identification. A sulfhemoglobin assay is a device consisting of the reagents,...

  6. 21 CFR 864.7250 - Erythropoietin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Erythropoietin assay. 864.7250 Section 864.7250... assay. (a) Identification. A erythropoietin assay is a device that measures the concentration of erythropoietin (an enzyme that regulates the production of red blood cells) in serum or urine. This...

  7. 21 CFR 864.7425 - Carboxyhemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carboxyhemoglobin assay. 864.7425 Section 864.7425 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... assay. (a) Identification. A carboxyhemoglobin assay is a device used to determine the...

  8. 21 CFR 866.3210 - Endotoxin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endotoxin assay. 866.3210 Section 866.3210 Food... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3210 Endotoxin assay. (a) Identification. An endotoxin assay is a device that uses serological techniques in whole blood. The device...

  9. Making transuranic assay measurements using modern controllers

    International Nuclear Information System (INIS)

    This paper describes methodology and computer-controlled instrumentation developed at the Los Alamos National Laboratory that accurately performs nondestructive assays of large containers bearing transuranic wastes and nonradioactive matrix materials. These assay systems can measure fissile isotopes with 1-mg sensitivity and spontaneous neutron-emitting isotopes at a 10-mg sensitivity. The assays are performed by neutron interrogation, detection, and counting in a custom assay chamber. An International Business Machines Personal Computer (IBM-PC) is used to control the CAMAC-based instrumentation system that acquires the assay data. 6 refs., 7 figs

  10. Establishment of Immunoradiometric Assay for Carcinoembryonic Antigen

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Two anti-CEA monoclonal antibodies are used, one is coated on the microtiter plate, the other is labeled to make 125I-CEAMcAb. The one-step assay is established based on immunoradiometric assay(IRMA). The sensitivity of the assay is 0.5 μ g/L. The intra-assay CVs and the inter-assay CVs are lower than 10.0% and 15.0%, respectively. The analytical recoveries are ranged from 97.4% to 107.8%. The reference cut-out value of 35 normal serum is lower than

  11. Predictive Assay For Cancer Targets

    Energy Technology Data Exchange (ETDEWEB)

    Suess, A; Nguyen, C; Sorensen, K; Montgomery, J; Souza, B; Kulp, K; Dugan, L; Christian, A

    2005-09-19

    Early detection of cancer is a key element in successful treatment of the disease. Understanding the particular type of cancer involved, its origins and probable course, is also important. PhIP (2-amino-1-methyl-6 phenylimidazo [4,5-b]pyridine), a heterocyclic amine produced during the cooking of meat at elevated temperatures, has been shown to induce mammary cancer in female, Sprague-Dawley rats. Tumors induced by PhIP have been shown to contain discreet cytogenetic signature patterns of gains and losses using comparative genomic hybridization (CGH). To determine if a protein signature exists for these tumors, we are analyzing expression levels of the protein products of the above-mentioned tumors in combination with a new bulk protein subtractive assay. This assay produces a panel of antibodies against proteins that are either on or off in the tumor. Hybridization of the antibody panel onto a 2-D gel of tumor or control protein will allow for identification of a distinct protein signature in the tumor. Analysis of several gene databases has identified a number of rat homologs of human cancer genes located in these regions of gain and loss. These genes include the oncogenes c-MYK, ERBB2/NEU, THRA and tumor suppressor genes EGR1 and HDAC3. The listed genes have been shown to be estrogen-responsive, suggesting a possible link between delivery of bio-activated PhIP to the cell nucleus via estrogen receptors and gene-specific PhIP-induced DNA damage, leading to cell transformation. All three tumors showed similar silver staining patterns compared to each other, while they all were different than the control tissue. Subsequent screening of these genes against those from tumors know to be caused by other agents may produce a protein signature unique to PhIP, which can be used as a diagnostic to augment optical and radiation-based detection schemes.

  12. Activity assay of membrane transport proteins

    Institute of Scientific and Technical Information of China (English)

    Hao Xie

    2008-01-01

    Membrane transport proteins are integral membrane proteins and considered as potential drug targets. Activity assay of transport proteins is essential for developing drugs to target these proteins. Major issues related to activity assessment of transport proteins include availability of transporters,transport activity of transporters, and interactions between ligands and transporters. Researchers need to consider the physiological status of proteins (bound in lipid membranes or purified), availability and specificity of substrates, and the purpose of the activity assay (screening, identifying, or comparing substrates and inhibitors) before choosing appropriate assay strategies and techniques. Transport proteins bound in vesicular membranes can be assayed for transporting substrate across membranes by means of uptake assay or entrance counterflow assay. Alternatively, transport proteins can be assayed for interactions with ligands by using techniques such as isothermal titration calorimetry, nuclear magnetic resonance spectroscopy, or surface plasmon resonance. Other methods and techniques such as fluorometry, scintillation proximity assay, electrophysiological assay, or stopped-flow assay could also be used for activity assay of transport proteins. In this paper the major strategies and techniques for activity assessment of membrane transport proteins are reviewed.

  13. Comet assay as a predictive assay for radiosensitivity of two human brain tumor cell lines

    International Nuclear Information System (INIS)

    Micronucleus assay and comet assay were compared as a predictive assay for radiosensitivity of tumors. Two human brain tumor cell lines, Becker (derived from astrocytoma) and ONS76 (derived from medulloblastoma) were used. Colony methods as the gold standard showed ONS76 as radiosensitive and Becker as radioresistant cell lines. Micronucleus assay revealed no different radiosensitivity between them. With comet assay, Becker cells received irradiation showed less damage to the DNA and faster repair of the damage than ONS76 cells did. The results correlate with those from colony methods. Comet assay is simple and rapid method for clinical use and it has an advantage not to establish the primary culture. Moreover, the results of comet assay showed not only DNA damage but also repair from the damage. It is concluded that comet assay is a superior method than micronucleus assay and has a potent candidate for clinical predictive assay. (author)

  14. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  15. A lateral electrophoretic flow diagnostic assay

    OpenAIRE

    Lin, R.; Skandarajah, A.; Gerver, RE; Neira, HD; Fletcher, DA; Herr, AE

    2015-01-01

    © 2015 The Royal Society of Chemistry. Immunochromatographic assays are a cornerstone tool in disease screening. To complement existing lateral flow assays (based on wicking flow) we introduce a lateral flow format that employs directed electrophoretic transport. The format is termed a "lateral e-flow assay" and is designed to support multiplexed detection using immobilized reaction volumes of capture antigen. To fabricate the lateral e-flow device, we employ mask-based UV photopatterning to ...

  16. A daunting challenge

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Bonde, Jesper; Ejegod, Ditte;

    2015-01-01

    We compared cytology with Hybrid Capture 2 (HC2), cobas, CLART and APTIMA Human Papillomavirus (HPV) assays in primary cervical screening at age 23-29 years based on data from the Danish Horizon study. SurePath samples were collected from 1278 women undergoing routine cytology-based screening...

  17. LT-HSC Methylcellulose Assay

    Science.gov (United States)

    Kerenyi, Marc A.

    2016-01-01

    Hematopoietic differentiation is a highly complex process originating from an extraordinary population of cells called long-term repopulating hematopoietic stem cells (LT-HSCs). The unique feature of all stem cells, including HSCs, is their exceptional ability to divide asymmetrically giving rise to two different kinds of offspring. One daughter cell becomes an LT-HSC itself (self-renews) to maintain the LT-HSC pool, whereas the second daughter cell pursues a differentiation fate to ultimately give rise to terminally differentiated mature blood cells (Orkin and Zon, 2008). Quantification of phenotypic LT-HSCs can be performed by multi-color flow cytometry and the gold standard for assessment of LT-HSC self-renewal and function is competitive bone marrow transplantation (Miller et al., 2008). Although these methods are irreplaceable to determine LT-HSC abundance and functionality, they have their disadvantages and limitations. For example, competitive bone marrow transplantation is typically monitored as a function of peripheral blood donor contribution over 12–16 weeks. While reduced peripheral blood donor contribution by itself signifies impairment in the stem/progenitor cells compartment, it cannot unambiguously discriminate between reduced LT-HSC self-renewal, impaired LT-HSC differentiation or compromised progenitor cell differentiation. Here we describe an LT-HSCs methylcellulose colony-forming assay, as a fast complementary in vitro method to directly assess LT-HSC differentiation capacity. As described in Kerenyi et al. (2013), this technique acts as a powerful tool to differentiate between LT-HSC or progenitor cell differentiation defects.

  18. Assessing sediment contamination using six toxicity assays

    Directory of Open Access Journals (Sweden)

    Allen G. BURTON Jr.

    2001-08-01

    Full Text Available An evaluation of sediment toxicity at Lake Orta, Italy was conducted to compare a toxicity test battery of 6 assays and to evaluate the extent of sediment contamination at various sediment depths. Lake Orta received excessive loadings of copper and ammonia during the 1900’s until a large remediation effort was conducted in 1989-90 using lime addition. Since that time, the lake has shown signs of a steady recovery of biological communities. The study results showed acute toxicity still exists in sediments at a depth of 5 cm and greater. Assays that detected the highest levels of toxicity were two whole sediment exposures (7 d using Hyalella azteca and Ceriodaphnia dubia. The MicrotoxR assay using pore water was the third most sensitive assay. The Thamnotox, Rototox, Microtox solid phase, and Seed Germination-Root Elongation (pore and solid phase assays showed occasional to no toxicity. Based on similarity of responses and assay sensitivity, the two most useful assays were the C. dubia (or H. azteca and Microtox pore water. These assays were effective at describing sediment toxicity in a weight-of-evidence approach.

  19. A bioluminescent assay for measuring glucose uptake.

    Science.gov (United States)

    Valley, Michael P; Karassina, Natasha; Aoyama, Natsuyo; Carlson, Coby; Cali, James J; Vidugiriene, Jolanta

    2016-07-15

    Identifying activators and inhibitors of glucose uptake is critical for both diabetes management and anticancer therapy. To facilitate such studies, easy-to-use nonradioactive assays are desired. Here we describe a bioluminescent glucose uptake assay for measuring glucose transport in cells. The assay is based on the uptake of 2-deoxyglucose and the enzymatic detection of the 2-deoxyglucose-6-phosphate that accumulates. Uptake can be measured from a variety of cell types, it can be inhibited by known glucose transporter inhibitors, and the bioluminescent assay yields similar results when compared with the radioactive method. With HCT 116 cells, glucose uptake can be detected in as little as 5000 cells and remains linear up to 50,000 cells with signal-to-background values ranging from 5 to 45. The assay can be used to screen for glucose transporter inhibitors, or by multiplexing with viability readouts, changes in glucose uptake can be differentiated from overall effects on cell health. The assay also can provide a relevant end point for measuring insulin sensitivity. With adipocytes and myotubes, insulin-dependent increases in glucose uptake have been measured with 10- and 2-fold assay windows, respectively. Significant assay signals of 2-fold or more have also been measured with human induced pluripotent stem cell (iPSC)-derived cardiomyocytes and skeletal myoblasts. PMID:27130501

  20. Development of an upconverting chelate assay

    Science.gov (United States)

    Xiao, Xudong; Haushalter, Jeanne P.; Kotz, Kenneth T.; Faris, Gregory W.

    2005-04-01

    We report progress on performing a cell-based assay for the detection of EGFR on cell surfaces by using upconverting chelates. An upconversion microscope has been developed for performing assays and testing optical response. A431 cells are labeled with europium DOTA and imaged using this upconverting microscope.

  1. Radioreceptor assay: theory and applications to pharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Perret, G. (U.E.R. de Medecine, Sante et Biologie Humaine, 93 - Bobigny (France)); Simon, P. (Faculte de Medecine Pitie-Salpetriere, 75 - Paris (France))

    The aim of the first part of this work is to present the theory of the radioreceptor assay and to compare it to the other techniques of radioanalysis (radioimmunoassay, competitive protein binding assays). The technology of the radioreceptor assay is then presented and its components (preparation of the receptors, radioligand, incubation medium) are described. The analytical characteristics of the radioreceptor assay (specificity, sensitivity, reproductibility, accuracy) and the pharmacological significance of the results are discussed. The second part is devoted to the description of the radioreceptor assays of some pharmacological classes (neuroleptics, tricyclic antidepressants, benzodiazepines, ..beta..-blockers, anticholinergic drugs) and to their use in therapeutic drug monitoring. In conclusion, by their nature, radioreceptor assays are highly sensitive, reliable, precise, accurate and simple to perform. Their chief disadvantage relates to specificity, since any substance having an appreciable affinity to the receptor site will displace the specifically bound radioligand. Paradoxically in some cases, this lack of specificity may be advantageous in that it allows for the detection of not only the apparent compound but of active metabolites and endogenous receptor agonists as well and in that radioreceptors assays can be devised for a whole pharmacological class and not only for one drug as it is the case for classical physico-chemical techniques. For all these reasons future of radioreceptor assay in pharmacology appears promising.

  2. Acellular comet assay: A tool for assessing variables influencing the alkaline comet assay

    International Nuclear Information System (INIS)

    In this study, an acellular modification to the alkaline comet assay to further evaluate key variables within the assay that may influence the outcome of genotoxicity studies is described. This acellular comet assay can detect differences of 0.2 Gy of 60Co gamma-ray radiation between 0 and 1 Gy and differences of 1 Gy between 0 and 8 Gy; thus, this assay is applicable for a wide range of DNA damage levels. It is also shown that DNA damage from different radiation energies was not significantly different from 60Co gamma-ray. This assay displayed a statistical increase in DNA damage due to uncontrolled exposure to natural light; however, the slope of the dose-response curve for light-exposed samples was similar to that for samples protected from light. A comparison of the alkaline comet assay with the acellular comet assay allowed for the intrinsic repair capacity of the alkaline comet assay to be quantified. (authors)

  3. Capillary Electrophoresis Analysis of Conventional Splicing Assays

    DEFF Research Database (Denmark)

    de Garibay, Gorka Ruiz; Acedo, Alberto; García-Casado, Zaida;

    2014-01-01

    Rare sequence variants in "high-risk" disease genes, often referred as unclassified variants (UVs), pose a serious challenge to genetic testing. However, UVs resulting in splicing alterations can be readily assessed by in vitro assays. Unfortunately, analytical and clinical interpretation...... of these assays is often challenging. Here, we explore this issue by conducting splicing assays in 31 BRCA2 genetic variants. All variants were assessed by RT-PCR followed by capillary electrophoresis and direct sequencing. If assays did not produce clear-cut outputs (Class-2 or Class-5 according to analytical...... International Agency for Research on Cancer guidelines), we performed qPCR and/or minigene assays. The latter were performed with a new splicing vector (pSAD) developed by authors of the present manuscript (patent #P201231427 CSIC). We have identified three clinically relevant Class-5 variants (c.682-2A>G, c...

  4. Probabilistic interpretation of radioactive waste assay

    International Nuclear Information System (INIS)

    The non-destructive assay of radioactive wastes from nuclear power plants and fuel cycle facilities is required for assessing the disposal risks. Such assay is influenced by two distinct facts: the statistical uncertainty of the measurement and the spatial uncertainty due to the random or at least unknown spatial distribution of the assayed material in a waste container. In this paper a probabilistic interpretation procedure is presented for a single-detector assay system of nuclear waste by one-shot passive gamma technique. The key parameter for this study, the average escape probability for photons, has been obtained by a specific-purpose Monte Carlo code, MCRW. The code has been developed to simulate the entire pulse height spectral responses for point sources located within the compartment which is the basic idea describing the degree of spatial homogeneity of the nuclear and matrix materials. The methodology presented here can be extended to actual radioactive waste assay

  5. The haemolytic antibody isotope release (HAIR) assay; an efficient alternative technique to conventional plaque assays

    International Nuclear Information System (INIS)

    The haemolytic antibody isotope release (HAIR) assay quantitates antibody production by splenic antibody-producing cells by lysis of chromium-51-labelled sheep red blood cells. The amount of antibody quantitated by the HAIR assay directly correlates with the number of antibody-producing cells measured by a conventional plaque assay. The HAIR assay is an easy, sensitive, and reproducible technique that is especially useful when large numbers of animals are required for testing. (author)

  6. Determination of cell survival after irradiation via clonogenic assay versus multiple MTT Assay - A comparative study

    OpenAIRE

    Buch Karl; Peters Tanja; Nawroth Thomas; Sänger Markus; Schmidberger Heinz; Langguth Peter

    2012-01-01

    Abstract For studying proliferation and determination of survival of cancer cells after irradiation, the multiple MTT assay, based on the reduction of a yellow water soluble tetrazolium salt to a purple water insoluble formazan dye by living cells was modified from a single-point towards a proliferation assay. This assay can be performed with a large number of samples in short time using multi-well-plates, assays can be performed semi-automatically with a microplate reader. Survival, the calc...

  7. Improved benzodiazepine radioreceptor assay using the MultiScreen (R) Assay System

    NARCIS (Netherlands)

    Janssen, MJ; Ensing, K; de Zeeuw, RA

    1999-01-01

    In this article, an improved benzodiazepine radioreceptor assay is described, which allows substantial reduction in assay time, The filtration in this method was performed by using the MultiScreen(R) Assay System. The latter consists of a 96-well plate with glass fibre filters sealed at the bottom,

  8. Simple UV spectrophotometric assay of Mefenamic acid

    Directory of Open Access Journals (Sweden)

    Dr. Safila Naveed

    2014-07-01

    Full Text Available Mefenamic acid belongs to non-steroidal antiinflammatory drugs (NSAID.. It is being used widely for the treatment of analgesia. It is also used as antirheumatic and antipyretic drug. Our aim of study is to develop a efficient least time consuming and simple spectrophotometric method for the assay of mefenamic acid. Comparision of assay of three different brands of mefenamic acid (mefnac,ponstan,dolar available in public medical store of Karachi, Pakistan has also been done. The assay is based on the ultraviolet UV absorbance maxima at about 288nm wavelength of mefenamic acid, water is used as solvent. A sample of drug was dissolved in water to produce a solution containing mefenamic acid. Similarly, a sample of ground tablets of different brand were dissolved in water and various dilutions were made. The absorbance of sample preparation was measured at 288nm against the solvent blank and the assay was determined by comparing with the absorbance of available brand. Our results reveals that among all the three brands of mefenamic acid (mefnac,ponstan,dolar rosulin and rovista shows highest percentage assay 107.5%. xplended and rosubar shows percent assay of 106.25% and 103.75% while rovactor shows lowest value for percentage assay 98.75%.

  9. Environmental herbicides and mycotoxin by inmunoraciochemical assay

    International Nuclear Information System (INIS)

    Immunochemical assays based on antigen antibody recognition, are at present very attractive analytical tools for determination of molecules present in different matrixes.Due to its specificity, sensitivity and easy application, the Immuno radiochemical assays have been adopted by international agencies for control procedures of environmental impact analytes. Optimization conditions for two contaminants, aflatoxin-B1 (AfB1, bacterial myco toxin from Aspergillus flavus) in dry food and atrazine (Atr, chloro-derivative triazine herbicides) in milk and water, by immunoradiometric assays based on the use of polyclonal antibodies for the mycotoxins and specific monoclonal antibody for the triazine derivatives, are presented.Liquid Chromatography is used as reference

  10. Radioreceptor assay of human growth hormone

    International Nuclear Information System (INIS)

    A radioreceptor assay for human growth hormone (hGH) was developed. The receptor preparation was 25,000g pellet from the livers of pregnant rabbits. Iodination of GH with 125I was preformed by the methods of Lactoperoxidase and Iodogen. The sensitivity of assay was 0.67 ± 0.11 ng/ml serum. Serum hGH levels in 72 cases of normal subjects, 102 cases of acromegaly were measured by radioreceptor assay (RRA), and the results were compared with those obtained by radioimmunoassay (RIA)

  11. Passive neutron assay of irradiated nuclear fuels

    International Nuclear Information System (INIS)

    Passive neutron assay of irradiated nuclear fuel has been investigated by calculations and experiments as a simple, complementary technique to the gamma assay. From the calculations it is found that the neutron emission arises mainly from the curium isotopes, the neutrons exhibit very good penetrability of the assemblies, and the neutron multiplication is not affected by the burnup. From the experiments on BWR and PWR assemblies, it is found that the neutron emission rate is proportional to burnup raised to 3.4 power. Recent investigations indicate that the passive neutron assay is a simple and useful technique to determine the consistency of burnups between assemblies. 10 refs

  12. Passive neutron assay of irradiated nuclear fuels

    International Nuclear Information System (INIS)

    Passive neutron assay of irradiated nuclear fuel has been investigated by calculations and experiments as a simple, complementary technique to the gamma assay. From the calculations it was found that the neutron emission arises mainly from the curium isotopes, the neutrons exhibit very good penetrability of the assemblies, and the neutron multiplication is not affected by the burnup. From the experiments on BWR and PWR assemblies, the neutron emission rate is proportional to burnup raised to 3.4 power. The investigations indicate that the passive neutron assay is a simple and useful technique to determine the consistency of burnups between assemblies

  13. Nondestructive assay measurements applied to reprocessing plants

    International Nuclear Information System (INIS)

    Nondestructive assay for reprocessing plants relies on passive gamma-ray spectrometry for plutonium isotopic and plutonium mass values of medium-to-low-density samples and holdup deposits; on active x-ray fluorescence and densitometry techniques for uranium and plutonium concentrations in solutions; on calorimetry for plutonium mass in product; and passive neutron techniques for plutonium mass in spent fuel, product, and waste. This paper will describe the radiation-based nondestructive assay techniques used to perform materials accounting measurements. The paper will also discuss nondestructive assay measurements used in inspections of reprocessing plants

  14. Determination of cell survival after irradiation via clonogenic assay versus multiple MTT Assay - A comparative study

    International Nuclear Information System (INIS)

    For studying proliferation and determination of survival of cancer cells after irradiation, the multiple MTT assay, based on the reduction of a yellow water soluble tetrazolium salt to a purple water insoluble formazan dye by living cells was modified from a single-point towards a proliferation assay. This assay can be performed with a large number of samples in short time using multi-well-plates, assays can be performed semi-automatically with a microplate reader. Survival, the calculated parameter in this assay, is determined mathematically. Exponential growth in both control and irradiated groups was proven as the underlying basis of the applicability of the multiple MTT assay. The equivalence to a clonogenic survival assay with its disadvantages such as time consumption was proven in two setups including plating of cells before and after irradiation. Three cell lines (A 549, LN 229 and F 98) were included in the experiment to study its principal and general applicability

  15. Live-cell luciferase assay of drug resistant cells

    OpenAIRE

    sprotocols

    2015-01-01

    To date, multiplexing cell-based assay is essential for high-throughput screening of molecular targets. Measuring multiple parameters of a single sample increases consistency and decrease time and cost of assay. Functional assay of living cell is useful as a first step of multiplexing assay, because live-cell assay allows following second assay using cell lysate or stained cell. However, live-cell assay of drug resistant cells that are highly activated of drug efflux mechanisms is sometimes u...

  16. Stochastic modeling for the COMET-assay

    OpenAIRE

    Boulesteix, Anne-Laure; Hösel, Volker; Liebscher, Volkmar

    2003-01-01

    We present a stochastic model for single cell gel electrophoresis (COMET-assay) data. Essential is the use of point process structures, renewal theory and reduction to intensity histograms for further data analysis.

  17. Proximity assays for sensitive quantification of proteins

    Directory of Open Access Journals (Sweden)

    Christina Greenwood

    2015-06-01

    Full Text Available Proximity assays are immunohistochemical tools that utilise two or more DNA-tagged aptamers or antibodies binding in close proximity to the same protein or protein complex. Amplification by PCR or isothermal methods and hybridisation of a labelled probe to its DNA target generates a signal that enables sensitive and robust detection of proteins, protein modifications or protein–protein interactions. Assays can be carried out in homogeneous or solid phase formats and in situ assays can visualise single protein molecules or complexes with high spatial accuracy. These properties highlight the potential of proximity assays in research, diagnostic, pharmacological and many other applications that require sensitive, specific and accurate assessments of protein expression.

  18. A novel parameter in comet assay measurements

    OpenAIRE

    Kirilova Milena; Ivanov Rumen; Miloshev George

    2005-01-01

    Single Cell Gel Electrophoresis (SCGE) or Comet assay is a very sensitive method for assessing damages in DNA on a single cell level. It has found many applications in fields where genotoxic activity could be an issue. In environmental monitoring, health care, food industry Comet assay is used with increasing popularity. For verifying the results obtained by this method many parameters could be monitored. To that end several software packages exist. In the conditions that we are suggesting on...

  19. The comet assay in nanotoxicology research.

    OpenAIRE

    Karlsson, Hanna L

    2010-01-01

    Nanoscale particles can have impressive and useful characteristics, but the same properties may be problematic for human health. From this perspective it is critical to assess the ability of nanoparticles to cause DNA damage. This review focuses on the use of the comet assay in nanotoxicology research. In the alkaline version of the assay, DNA strand breaks and alkali-labile sites are detected and oxidatively damaged DNA can be analyzed using the enzyme formamidopyrimidine glycosylase. The ar...

  20. A lateral electrophoretic flow diagnostic assay

    OpenAIRE

    Lin, Robert; Skandarajah, Arunan; Gerver, Rachel E.; Neira, Hector D.; Daniel A Fletcher; Herr, Amy E.

    2015-01-01

    Immunochromatographic assays are a cornerstone tool in disease screening. To complement existing lateral flow assays (based on wicking flow) we introduce a lateral flow format that employs directed electrophoretic transport. The format is termed a “lateral e-flow assay” and is designed to support multiplexed detection using immobilized reaction volumes of capture antigen. To fabricate the lateral e-flow device, we employ mask-based UV photopatterning to selectively immobilize unmodified captu...

  1. Automated optical sensing system for biochemical assays

    Science.gov (United States)

    Oroszlan, Peter; Duveneck, Gert L.; Ehrat, Markus; Widmer, H. M.

    1994-03-01

    In this paper, we present a new system called FOBIA that was developed and optimized with respect to automated operation of repetitive assay cycles with regenerable bioaffinity sensors. The reliability and precision of the new system is demonstrated by an application in a competitive assay for the detection of the triazine herbicide Atrazine. Using one sensor in more than 300 repetitive cycles, a signal precision better than 5% was achieved.

  2. Passive nondestructive assay of nuclear materials

    International Nuclear Information System (INIS)

    The term nondestructive assay (NDA) is applied to a series of measurement techniques for nuclear fuel materials. The techniques measure radiation induced or emitted spontaneously from the nuclear material; the measurements are nondestructive in that they do not alter the physical or chemical state of the nuclear material. NDA techniques are characterized as passive or active depending on whether they measure radiation from the spontaneous decay of the nuclear material or radiation induced by an external source. This book emphasizes passive NDA techniques, although certain active techniques like gamma-ray absorption densitometry and x-ray fluorescence are discussed here because of their intimate relation to passive assay techniques. The principal NDA techniques are classified as gamma-ray assay, neutron assay, and calorimetry. Gamma-ray assay techniques are treated in Chapters 1--10. Neutron assay techniques are the subject of Chapters 11--17. Chapters 11--13 cover the origin of neutrons, neutron interactions, and neutron detectors. Chapters 14--17 cover the theory and applications of total and coincidence neutron counting. Chapter 18 deals with the assay of irradiated nuclear fuel, which uses both gamma-ray and neutron assay techniques. Chapter 19 covers perimeter monitoring, which uses gamma-ray and neutron detectors of high sensitivity to check that no unauthorized nuclear material crosses a facility boundary. The subject of Chapter 20 is attribute and semiquantitative measurements. The goal of these measurements is a rapid verification of the contents of nuclear material containers to assist physical inventory verifications. Waste and holdup measurements are also treated in this chapter. Chapters 21 and 22 cover calorimetry theory and application, and Chapter 23 is a brief application guide to illustrate which techniques can be used to solve certain measurement problems

  3. Controlling variation in the comet assay

    Directory of Open Access Journals (Sweden)

    Andrew Richard Collins

    2014-10-01

    Full Text Available Variability of the comet assay is a serious issue, whether it occurs from experiment to experiment in the same laboratory, or between different laboratories analysing identical samples. Do we have to live with high variability, just because the comet assay is a biological assay rather than analytical chemistry? Numerous attempts have been made to limit variability by standardising the assay protocol, and the critical steps in the assay have been identified; agarose concentration, duration of alkaline incubation, and electrophoresis conditions (time, temperature and voltage gradient are particularly important. Even when these are controlled, variation seems to be inevitable. It is helpful to include in experiments reference standards, i.e. cells with a known amount of specific damage to the DNA. They can be aliquots frozen from a single large batch of cells, either untreated (negative controls or treated with, for example, H2O2 or X-rays to induce strand breaks (positive control for the basic assay, or photosensitiser plus light to oxidise guanine (positive control for Fpg- or OGG1-sensitive sites. Reference standards are especially valuable when performing a series of experiments over a long period - for example, analysing samples of white blood cells from a large human biomonitoring trial - to check that the assay is performing consistently, and to identify anomalous results necessitating a repeat experiment. The reference values of tail intensity can also be used to iron out small variations occurring from day to day. We present examples of the use of reference standards in human trials, both within one laboratory and between different laboratories, and describe procedures that can be used to control variation.

  4. Cell Culture Assay for Human Noroviruses [response

    Energy Technology Data Exchange (ETDEWEB)

    Straub, Tim M.; Honer Zu Bentrup, Kerstin; Orosz Coghlan, Patricia; Dohnalkova, Alice; Mayer, Brooke K.; Bartholomew, Rachel A.; Valdez, Catherine O.; Bruckner-Lea, Cindy J.; Gerba, Charles P.; Abbaszadegan, Morteza A.; Nickerson, Cheryl A.

    2007-07-01

    We appreciate the comments provided by Leung et al., in response to our recently published article “In Vitro Cell Culture Infectivity Assay for Human Noroviruses” by Straub et al. (1). The specific aim of our project was to develop an in vitro cell culture infectivity assay for human noroviruses (hNoV) to enhance risk assessments when they are detected in water supplies. Reverse transcription (RT) qualitative or quantitative PCR are the primary assays for waterborne NoV monitoring. However, these assays cannot distinguish between infectious vs. non-infectious virions. When hNoV is detected in water supplies, information provided by our infectivity assay will significantly improve risk assessment models and protect human health, regardless of whether we are propagating NoV. Indeed, in vitro cell culture infectivity assays for the waterborne pathogen Cryptosporidium parvum that supplement approved fluorescent microscopy assays, do not result in amplification of the environmentally resistant hard-walled oocysts (2). However, identification of life cycle stages in cell culture provides evidence of infectious oocysts in a water supply. Nonetheless, Leung et al.’s assertion regarding the suitability of our method for the in vitro propagation of high titers of NoV is valid for the medical research community. In this case, well-characterized challenge pools of virus would be useful for developing and testing diagnostics, therapeutics, and vaccines. As further validation of our published findings, we have now optimized RT quantitative PCR to assess the level of viral production in cell culture, where we are indeed finding significant increases in viral titer. The magnitude and time course of these increases is dependent on both virus strain and multiplicity of infection. We are currently preparing a manuscript that will discuss these findings in greater detail, and the implications this may have for creating viral challenge pools

  5. The Comet Assay: Tails of the (Unexpected. Use of the comet assay in pharmaceutical development.

    Directory of Open Access Journals (Sweden)

    Bas-jan Van Der Leede

    2015-08-01

    Full Text Available In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by regulatory guidance. In this presentation we want to give insight into the circumstances in vivo comet assay is deployed in a Genetic Toxicology Department of a pharmaceutical company. As the in vivo comet assay is a salvage assay, it means that some events have occurred in an in vitro assay and that the compound (or metabolite responsible for this signal is potentially deselected for further development. More than often the decision to perform an in vivo comet assay is at a very early stage in development and the first time that the compound will be tested in vivo at high/toxic dose levels. As almost no toxicokinetic data and tissue distribution data are available a careful design with maximizes the chances for successful mitigation is necessary. Decisions on acute or repeated dosing need to be made and arrangements for combining the in vivo comet assay with the in vivo micronucleus assay are to be considered. Often synthesis methods need to be scaled up fast to provide the required amount of compound and information on suitable formulations needs to be in place. As exposure data is crucial for interpretation of results, analytical methods need to be brought in place rapidly. An experienced multi skilled and communicative team needs to be available to deploy successfully this kind of assays at an early stage of development. We will present a few scenarios on study conduct and demonstrate how this assay can make a difference for the further development of a new drug.

  6. Using the CPTAC Assay Portal to identify and implement highly characterized targeted proteomics assays

    Energy Technology Data Exchange (ETDEWEB)

    Whiteaker, Jeffrey R.; Halusa, Goran; Hoofnagle, Andrew N.; Sharma, Vagisha; MacLean, Brendan; Yan, Ping; Wrobel, John; Kennedy, Jacob; Mani, DR; Zimmerman, Lisa J.; Meyer, Matthew R.; Mesri, Mehdi; Boja, Emily; Carr, Steven A.; Chan, Daniel W.; Chen, Xian; Chen, Jing; Davies, Sherri; Ellis, Matthew; Fenyo, David; Hiltket, Tara; Ketchum, Karen; Kinsinger, Christopher; Kuhn, Eric; Liebler, Daniel; Liu, Tao; Loss, Michael; MacCoss, Michael; Qian, Weijun; Rivers, Robert; Rodland, Karin D.; Ruggles, Kelly; Scott, Mitchell; Smith, Richard D.; Thomas, Stefani N.; Townsend, Reid; Whiteley, Gordon; Wu, Chaochao; Zhang, Hui; Zhang, Zhen; Rodriguez, Henry; Paulovich, Amanda G.

    2016-02-12

    The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative to other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and post-translational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories.

  7. Using the CPTAC Assay Portal to identify and implement highly characterized targeted proteomics assays

    Science.gov (United States)

    Whiteaker, Jeffrey R; Halusa, Goran N; Hoofnagle, Andrew N; Sharma, Vagisha; MacLean, Brendan; Yan, Ping; Wrobel, John A; Kennedy, Jacob; Mani, DR; Zimmerman, Lisa J; Meyer, Matthew R.; Mesri, Mehdi; Abbatiello, Susan E; Boja, Emily; Carr, Steven A.; Chan, Daniel W.; Chen, Xian; Chen, Jing; Davies, Sherri R; Ellis, Matthew J. C.; Fenyö, David; Hiltke, Tara; Ketchum, Karen A.; Kinsinger, Chris; Kuhn, Eric; Liebler, Daniel C.; Lin, De; Liu, Tao; Loss, Michael; MacCoss, Michael J; Qian, Wei-Jun; Rivers, Robert; Rodland, Karin D.; Ruggles, Kelly V; Scott, Mitchell G; Smith, Richard D.; Thomas, Stefani; Townsend, R. Reid; Whiteley, Gordon; Wu, Chaochao; Zhang, Hui; Zhang, Zhen; Rodriguez, Henry; Paulovich, Amanda G

    2016-01-01

    Summary The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative to other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and post-translational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories. PMID:26867747

  8. Comet assay on mice testicular cells

    Directory of Open Access Journals (Sweden)

    Anoop Kumar Sharma

    2015-05-01

    Full Text Available Heritable mutations may result in a variety of adverse outcomes including genetic disease in the offspring. In recent years the focus on germ cell mutagenicity has increased and the “Globally Harmonized System of Classification and Labelling of Chemicals (GHS” has published classification criteria for germ cell mutagens (Speit et al., 2009. The in vivo Comet assay is considered a useful tool for investigating germ cell genotoxicity. In the present study DNA strand breaks in testicular cells of mice were investigated. Different classes of chemicals were tested in order to evaluate the sensitivity of the comet assay in testicular cells. The chemicals included environmentally relevant substances such as Bisphenol A, PFOS and Tetrabrombisphenol A. Statistical power calculations will be presented to aid in the design of future Comet assay studies on testicular cells. Power curves were provided with different fold changes in % tail DNA, different number of cells scored and different number of gels (Hansen et al., 2014. An example is shown in Figure 1. A high throughput version of the Comet assay was used. Samples were scored with a fully automatic comet assay scoring system that provided faster scoring of randomly selected cells.

  9. The micronucleus assay in radiation accidents

    International Nuclear Information System (INIS)

    The cytokinesis-block micronucleus assay in peripheral blood lymphocytes is a standardised and validated technique for bio dosimetry. Automated scoring of micronuclei allows large scale applications as in population triage in case of radiation accidents or malevolent use of radioactive sources. The dose detection limit (95% confidence) of the micronucleus assay for individual dose assessment is restricted to 0.2 Gy but can be decreased to 0.1 Gy by scoring centromeres in micronuclei using fluorescence in situ hybridization (FISH). In the past the micronucleus assay was applied for a number of large scale bio monitoring studies of nuclear power plant workers and hospital workers. Baseline micronucleus frequencies depend strongly on age and gender. The assay was also already used for bio dosimetry of radiation accidents. In a multiple endpoint bio dosimetry study for dose assessment of a worker exposed accidentally in 2003 to X-rays, a good agreement was obtained between dose estimates resulting from the micronucleus assay, the scoring of dicentrics and translocations. Automated scoring of micronuclei in combination with centromere signals, allowing systematic bio dosimetry of exposed populations, remains a challenge for the future.

  10. Comet assay on tetraploid yeast cells

    DEFF Research Database (Denmark)

    Rank, Jette; Syberg, Kristian; Jensen, Klara

    2009-01-01

    Tetraploid yeast cells (Saccharomyces cerevisiae) were used in the comet assay with the intention of developing a new, fast and easy assay for detecting environmental genotoxic agents without using higher organisms. Two DNA-damaging chemicals, H2O2 and acrylamide, together with wastewater from...... three municipal treatment plants were tested for their effect on the yeast-cell DNA. The main problem with using yeast in the comet assay is the necessity to degrade the cell wall. This was achieved by using Zymolase 100 T twice during the procedure, since Zymolase 20 T did not open the cell wall....... Analytical problems that arose due to the small amount of DNA in the yeast nuclei in haploid and diploid cells, which contain 13 Mbp and 26 Mbp DNA per cell, respectively, were solved by using tetraploid yeast cells (52 Mbp) instead. DNA damage was shown after exposure to H2O2 and acrylamide. The lowest dose...

  11. Development of an integrated assay facility

    International Nuclear Information System (INIS)

    The I.R.I.S. concept proposed the use of passive examination and active interrogation techniques in an integrated assay facility. A linac would generate the interrogating gamma and neutron beams. Insufficiently detailed knowledge about active neutron and gamma interrogation of 500 litre drums of cement immobilised intermediate level waste led to a research programme which is now in its main experimental stage. Measurements of interrogation responses are being made using simulated waste drums containing actinide samples and calibration sources, in an experimental assay assembly. Results show that responses are generally consistent with theory, but that improvements are needed in some areas. A preliminary appraisal of the engineering and economic aspects of integrated assay shows that correct operational sequencing is required to achieve the short cycle time needed for high throughput. The main engineering features of a facility have been identified

  12. Monitoring environmental exposures with semen assays

    International Nuclear Information System (INIS)

    Semen studies in humans and animals have yielded extensive and compelling evidence that sperm can be used to assess reproductive potential and diagnose pathology. More recent studies on mutagens and carcinogens both at this and other laboratories suggest that a combination of mouse and human assays can be an efficient, effective approach to monitoring for reproductive hazards in the environment. We are investigating the potential of using variability in sperm morphology and DNA content to quantify and monitor the effects of environmental agents on the human testes. Here we review the status of human and mouse assays for environmental surveillance, discuss the genetic and fertility implications of chemically induced semen changes, and describe the high-speed flow methods being developed to automate sperm assays

  13. Fungicide resistance assays for fungal plant pathogens.

    Science.gov (United States)

    Secor, Gary A; Rivera, Viviana V

    2012-01-01

    Fungicide resistance assays are useful to determine if a fungal pathogen has developed resistance to a fungicide used to manage the disease it causes. Laboratory assays are used to determine loss of sensitivity, or resistance, to a fungicide and can explain fungicide failures and for developing successful fungicide recommendations in the field. Laboratory assays for fungicide resistance are conducted by measuring reductions in growth or spore germination of fungi in the presence of fungicide, or by molecular procedures. This chapter describes two techniques for measuring fungicide resistance, using the sugarbeet leaf spot fungus Cercospora beticola as a model for the protocol. Two procedures are described for fungicides from two different classes; growth reduction for triazole (sterol demethylation inhibitor; DMI) fungicides, and inhibition of spore germination for quinone outside inhibitor (QoI) fungicides.

  14. Nuclear Resonance Fluorescence for Materials Assay

    International Nuclear Information System (INIS)

    This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has been performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX?s photon transport physics for accurately describing photon scattering processes that are important contributions to the background and impact the applicability of the NRF assay technique.

  15. Detection of Eperythrozoon wenyoni by PCR assay

    Institute of Scientific and Technical Information of China (English)

    Jian WANG; Yutao ZHU; Jianhua QIN; Fumei ZHANG; Yuelan ZHAO

    2009-01-01

    The objective of this research was to develop a detection method for Eperythrozoon wenyoni infection using polymerase chain reaction (PCR) assay technique. A pair of primers was designed and synthesized according to the conservative sequence 16S rRNA. The PCR assay was performed with the primers. A 985-bp fragment was amplified by using PCR. The amplified fragments with the expected size were identified by EcoR I restriction digestion. The crossing-reaction, specific-reaction and duplicate-reaction indicated that the PCR method is a specific, sensitive, fast and effective method for diagnosing E. Wenyoni infection at group level.

  16. A new fluorescent assay for enalapril maleate.

    Science.gov (United States)

    de los A Oliva, María; Sombra, Lorena L; Olsina, Roberto A; Masi, Adriana N

    2005-09-01

    A new spectrofluorimetric method for the enalapril maleate monitoring was studied. Enalapril maleate was found to be highly photolabile. This drug was evaluated according to photodegradation assay at pH 2.5 and 6. Enalapril maleate was exposed to UVA-UVB radiations. Under these specific conditions was found as degradation product, the diketopiperazine. The modification of the fluorescent properties of enalapril maleate in solution after exposure UV-radiation and the degradation mechanisms were studied. The photodegradation was followed by the developed spectrofluorimetric assay.

  17. Relationship between the radioisotopic footpad assay and other immunological assays in tumor bearing rats

    International Nuclear Information System (INIS)

    KMT-17, a fibrosarcoma induced by 3-methylcholanthrene in a WKA rat, is a sensitive tumor to various kinds of immunological assays and is a suitable model tumor for the study of the immune status in tumor bearing hosts. The antitumor immune response of KMT-17 bearing rats was studied by a radioisotopic footpad assay (FPA) in comparison with other in vivo and in vitro assays. Delayed hypersensitivity to tumor antigens measured by the FPA was observed from the 8th day after transplantation of KMT-17 cells, reached a peak on the 12 - 15th day, and then declined in the late stage on the 17th day. The kinetics of the FPA correlated well with those of an in vivo Winn assay and of an in vitro lymphocyte cytotoxicity assay (51Cr-release assay). The appearance of an antitumor antibody detected by a complement dependent cytotoxicity test also correlated well with the kinetics of the FPA. A growth inhibition assay (GIA) for non-specific cell-mediated immunity also showed similar kinetics to that of the FPA. The delayed hypersensitivity footpad reaction to tumor cell extracts measured by this FPA was tumor-specific. These results suggest that the FPA is a simple and reliable in vivo assay for evaluating antitumor immunity in tumor bearing hosts. (author)

  18. Instructions for Uploading Data to the Assay Portal - Instructions for Uploading Data to the Assay Portal

    Science.gov (United States)

    This document provides instructions for configuring and uploading data files to the CPTAC Assay Portal. It is divided into sections, with an overview checklist provided at the end. If help is needed at any stage of the process, please use the support page: https://assays.cancer.gov/support/

  19. The Comet Assay: Tails of the (Un)expected. Use of the comet assay in pharmaceutical development.

    OpenAIRE

    Bas-jan Van Der Leede

    2015-01-01

    In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by regulatory guidance. In this presentation we want to give insight into the circumstances in vivo comet assay is deployed in a Genetic Toxicology Department of a pharmaceutical company. As the in vivo comet assay is a salvage assay, it means that some events have occu...

  20. Serum Aminoglycoside Assay by Enzyme-Mediated Immunoassay (EMIT): Correlation with Radioimmunoassay, Fluoroimmunoassay, and Acetyltransferase and Microbiological Assays

    OpenAIRE

    White, L O; Scammell, L. M.; Reeves, D S

    1981-01-01

    Enzyme-mediated immunoassay (EMIT) serum aminoglycoside assay results were accurate and precise and correlated well with radioimmunoassay, fluoroimmunoassay, and acetyltransferase and microbiological assay determinations.

  1. Functionalized Nanofiber Meshes Enhance Immunosorbent Assays.

    Science.gov (United States)

    Hersey, Joseph S; Meller, Amit; Grinstaff, Mark W

    2015-12-01

    Three-dimensional substrates with high surface-to-volume ratios and subsequently large protein binding capacities are of interest for advanced immunosorbent assays utilizing integrated microfluidics and nanosensing elements. A library of bioactive and antifouling electrospun nanofiber substrates, which are composed of high-molecular-weight poly(oxanorbornene) derivatives, is described. Specifically, a set of copolymers are synthesized from three 7-oxanorbornene monomers to create a set of water insoluble copolymers with both biotin (bioactive) and triethylene glycol (TEG) (antifouling) functionality. Porous three-dimensional nanofiber meshes are electrospun from these copolymers with the ability to specifically bind streptavidin while minimizing the nonspecific binding of other proteins. Fluorescently labeled streptavidin is used to quantify the streptavidin binding capacity of each mesh type through confocal microscopy. A simplified enzyme-linked immunosorbent assay (ELISA) is presented to assess the protein binding capabilities and detection limits of these nanofiber meshes under both static conditions (26 h) and flow conditions (1 h) for a model target protein (i.e., mouse IgG) using a horseradish peroxidase (HRP) colorimetric assay. Bioactive and antifouling nanofiber meshes outperform traditional streptavidin-coated polystyrene plates under flow, validating their use in future advanced immunosorbent assays and their compatibility with microfluidic-based biosensors.

  2. Enzymatic assay for methotrexate in erythrocytes

    DEFF Research Database (Denmark)

    Schrøder, H; Heinsvig, E M

    1985-01-01

    Methotrexate (MTX) accumulates in erythrocytes in MTX-treated patients. We present a modified enzymatic assay measuring MTX concentrations between 10 and 60 nmol/l in erythrocytes, adapted for a centrifugal analyser (Cobas Bio). About 40 patient's samples could be analysed within 1 h. The detection...

  3. Endoproteolytic activity assay in malting barley

    Directory of Open Access Journals (Sweden)

    Blanca Gómez Guerrero

    2013-12-01

    Full Text Available Hydrolysis of barley proteins into peptides and amino acids is one of the most important processes during barley germination.The degradation of the endosperm stored proteins facilitates water and enzyme movements, enhances modification, liberates starch granules and increases soluble amino nitrogen. Protease activity is the result of the activities of a mixture of exo- and endo-proteases. The barley proteins are initially solubilized by endo-proteases and the further by exo-proteases. Four classes of endo-proteases have been described: serine-proteases, cysteine-proteases, aspartic-proteases and metallo-proteases. The objective of this work was to develop a rapid and colorimetric enzymatic assay to determine the endo-proteolytic activity of the four endo-protease classes using two different substrates: azo-gelatin and azo-casein. Optimum conditions for the assays such as: pH,reaction time and temperature and absorbance scale were determined. Azo-gelatin presented several difficulties in standardizing an “in solution” assay. On the other hand, azo-casein allowed standardization of the assay for the four enzyme classes to produce consistent results. The endo-proteoteolytic method developed was applied to determine the endo-protease activity in barley, malt and wort.

  4. Verification of prior measurements by nondestructive assay

    International Nuclear Information System (INIS)

    Emphasis in this report is placed on the factors affecting nondestructive assay (NDA) measurement accuracies and the selection of the appropriate NDA techniques for certain measurements based on these factors. Factors affecting measurement accuracies are operational characteristics, isotopic composition of SNM sample, response dependence on the SNM and matrix materials within sample, and composition and dimension of the container

  5. Calcium flux assay in Xenopus oocytes.

    Science.gov (United States)

    Murphy, P M

    2001-05-01

    Many G protein-coupled receptors of interest to neuroscientists induce transient increases in [Ca(2+)](i), which can be used as a convenient measure of receptor activation in a variety of applications. This unit describes a simple calcium flux assay applied to Xenopus oocytes. PMID:18428482

  6. Benzodiazepine Synthesis and Rapid Toxicity Assay

    Science.gov (United States)

    Fletcher, James T.; Boriraj, Grit

    2010-01-01

    A second-year organic chemistry laboratory experiment to introduce students to general concepts of medicinal chemistry is described. Within a single three-hour time window, students experience the synthesis of a biologically active small molecule and the assaying of its biological toxicity. Benzodiazepine rings are commonly found in antidepressant…

  7. A novel fluorescent assay for sucrose transporters

    Directory of Open Access Journals (Sweden)

    Gora Peter J

    2012-04-01

    Full Text Available Abstract Background We have developed a novel assay based on the ability of type I sucrose uptake transporters (SUTs to transport the fluorescent coumarin β-glucoside, esculin. Budding yeast (Saccharomyces cerevisiae is routinely used for the heterologous expression of SUTs and does not take up esculin. Results When type I sucrose transporters StSUT1 from potato or AtSUC2 from Arabidopsis were expressed in yeast, the cells were able to take up esculin and became brightly fluorescent. We tested a variety of incubation times, esculin concentrations, and buffer pH values and found that for these transporters, a 1 hr incubation at 0.1 to 1 mM esculin at pH 4.0 produced fluorescent cells that were easily distinguished from vector controls. Esculin uptake was assayed by several methods including fluorescence microscopy, spectrofluorometry and fluorescence-activiated cell sorting (FACS. Expression of the type II sucrose transporter OsSUT1 from rice did not result in increased esculin uptake under any conditions tested. Results were reproduced successfully in two distinct yeast strains, SEY6210 (an invertase mutant and BY4742. Conclusions The esculin uptake assay is rapid and sensitive and should be generally useful for preliminary tests of sucrose transporter function by heterologous expression in yeast. This assay is also suitable for selection of yeast showing esculin uptake activity using FACS.

  8. Non-separation assay for glycohemoglobin.

    Science.gov (United States)

    Blincko, S; Edwards, R

    1998-06-01

    The determination of glycohemoglobin [HbA1c, HbA1, or total glycohemoglobin (GHb)] has become an established procedure in the management of diabetes mellitus. Here, we describe the development of a simple, fluorescence, non-separation assay for the percentage of GHb (%GHb). The fluorescence of an eosin-boronic acid derivative when it was mixed with hemolysates of unwashed erythrocytes was quenched in proportion to the percentage of glycohemoglobin. Measurement of the fluorescence intensity gave an estimate of GHb in the sample, and measurement of light absorbance gave an estimate of total hemoglobin. A combination of the two measurements gave the assay response. Comparison with HPLC (Menarini-Arkray HA-8140 fully automated analyzer) for the percentage of HbA1 (%HbA1) gave %GHb(NETRIA) = 1.1(SD +/-0.03)%HbA1 +0.6(SD +/-0.3), S(y/x) = 0.821, r = 0.972, n = 80; comparison for HbA1c gave %GHb(NETRIA) = 1.3(SD +/-0.04)%HbA1c + 1.8(SD +/-0.3), S(y/x) = 0.813, r = 0.973, n = 80. Precision, estimated as the percentage of the CV of the %GHb assay results, was <2% (intraassay, range 5-22% GHb) and <4.2% (interassay, range 4-16% GHb). Dilution of a high-percentage GHb sample lysate showed that the assay was linear, and addition of glucose (60 mmol/L), bilirubin (250 micromol/L), and triglycerides (14 mmol/L) to low, medium, and high %GHb samples showed no clinical interference in assay results. PMID:9625057

  9. Production and assay of forskolin antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ho, L.T.; Ho, R.J.

    1986-05-01

    Forskolin (Fo), a cardiovascular active diterpene of plant origin, has been widely used as a research tool in regulation of the catalytic activity of adenylate cyclase (AC). A linear relationship of Fo binding to plasma membrane with activation of AC has been reported. The present abstract describes the production and assay of Fo antibodies (AB). 7-0-Hemisuccinyl-7-deacetyl Fo, coupled to either human serum albumin or goat IgG, was injected into goats to elicit AB to Fo haptan. AB to Fo in antiserum or an isolated IgG fraction was tested by two assay methods, a radioimmunoassay using /sup 3/H-Fo as a tracer and a colorimetric enzyme-linked immunosorbent assay (ELISA) using horse radish peroxidase-rabbit anti goat IgG as indicator. The titers for Fo antiserum were 4000-10,000. In the defined assay condition, approximately 20-25% of the added /sup 3/H-Fo was found to bind to AB. The bound radioactivity was displaced by Fo-HSA or Fo-goat IgG or free unlabelled Fo ranging from 0.5-50 pmol/tube, or 5-500 nM. The IC/sub 50/ was approximately 8-10 pmol/tube or 80-100 nM. The binding of HRP-rabbit anti goat IgG in the ELISA was inhibited by proper Fo conjugate. The development of methods for production and assay for Fo AB may be useful in the study of mechanism of activation of AC by Fo and Fo-like compound.

  10. Production and assay of forskolin antibodies

    International Nuclear Information System (INIS)

    Forskolin (Fo), a cardiovascular active diterpene of plant origin, has been widely used as a research tool in regulation of the catalytic activity of adenylate cyclase (AC). A linear relationship of Fo binding to plasma membrane with activation of AC has been reported. The present abstract describes the production and assay of Fo antibodies (AB). 7-0-Hemisuccinyl-7-deacetyl Fo, coupled to either human serum albumin or goat IgG, was injected into goats to elicit AB to Fo haptan. AB to Fo in antiserum or an isolated IgG fraction was tested by two assay methods, a radioimmunoassay using 3H-Fo as a tracer and a colorimetric enzyme-linked immunosorbent assay (ELISA) using horse radish peroxidase-rabbit anti goat IgG as indicator. The titers for Fo antiserum were 4000-10,000. In the defined assay condition, approximately 20-25% of the added 3H-Fo was found to bind to AB. The bound radioactivity was displaced by Fo-HSA or Fo-goat IgG or free unlabelled Fo ranging from 0.5-50 pmol/tube, or 5-500 nM. The IC50 was approximately 8-10 pmol/tube or 80-100 nM. The binding of HRP-rabbit anti goat IgG in the ELISA was inhibited by proper Fo conjugate. The development of methods for production and assay for Fo AB may be useful in the study of mechanism of activation of AC by Fo and Fo-like compound

  11. 21 CFR 864.7100 - Red blood cell enzyme assay.

    Science.gov (United States)

    2010-04-01

    ... enzyme assay. (a) Identification. Red blood cell enzyme assay is a device used to measure the activity in... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Red blood cell enzyme assay. 864.7100 Section 864... kinase or 2,3-diphosphoglycerate. A red blood cell enzyme assay is used to determine the enzyme...

  12. 21 CFR 864.7375 - Glutathione reductase assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Glutathione reductase assay. 864.7375 Section 864... reductase assay. (a) Identification. A glutathione reductase assay is a device used to determine the... fluorescence and photometry. The results of this assay are used in the diagnosis of liver disease,...

  13. 21 CFR 864.7455 - Fetal hemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal hemoglobin assay. 864.7455 Section 864.7455... assay. (a) Identification. A fetal hemoglobin assay is a device that is used to determine the presence... hemoglobin present. The assay may be used to detect fetal red cells in the maternal circulation or to...

  14. Short communication. Microculture syncytia assay for bovine leukemia virus

    Energy Technology Data Exchange (ETDEWEB)

    Paul, P.S.; Castro, A.E.; Pomeroy, K.A.; Johnson, D.W.; Muscoplat, C.C.

    1978-01-01

    A microculture syncytia assay for the detection of bovine leukemia virus (BLV) has been described and compared with the conventional macroculture assay. The microculture assay required fewer indicator cells, was as sensitive as the macroculture assay and provided a reproducible test for the detection and titration of BLV.

  15. Comparative titers of egg assay against immunofluorescent assay of Chlamydia psittaci.

    OpenAIRE

    Tessler, J

    1985-01-01

    A comparison of titers was made between an egg assay and a direct fluorescent antibody assay of three chlamydial strains propagated in Vero cells with and without cortisone plus cytochalasin B. The titer of NJ-1 strain was similar in the egg titration and the fluorescent antibody assay in the untreated sample and a little lower for the sample treated with cytochalasin B and cortisone. The SCT and CDC strains had approximately the same titers in the egg titration and the fluorescent antibody a...

  16. A quantitative comet infection assay for influenza virus

    OpenAIRE

    Lindsay, Stephen M.; Timm, Andrea; Yin, John

    2011-01-01

    The virus comet assay is a cell-based virulence assay used to evaluate an antiviral drug or antibody against a target virus. The comet assay differs from the plaque assay in allowing spontaneous flows in 6-well plates to spread virus. When implemented quantitatively the comet assay has been shown to have an order-of-magnitude greater sensitivity to antivirals than the plaque assay. In this study, a quantitative comet assay for influenza virus is demonstrated, and is shown to have a 13-fold in...

  17. Is the Comet Assay a Sensitive Procedure for Detecting Genotoxicity?

    OpenAIRE

    Sasaki, Yu F.; Satomi Kawaguchi; Takanori Nakamura; Gisho Honda; Ayumi Yamamoto

    2010-01-01

    Although the Comet assay, a procedure for quantitating DNA damage in mammalian cells, is considered sensitive, it has never been ascertained that its sensitivity is higher than the sensitivity of other genotoxicity assays in mammalian cells. To determine whether the power of the Comet assay to detect a low level of genotoxic potential is superior to those of other genotoxicity assays in mammalian cells, we compared the results of Comet assay with those of micronucleus test (MN test). WTK1 hum...

  18. Comparison of an enzyme-linked immunosorbent assay, an immunofluorescence assay and a hemagglutination inhibition assay for detection of antibodies to K-papovavirus in mice.

    NARCIS (Netherlands)

    J. Groen (Jan); A.D.M.E. Osterhaus (Ab); H.W.J. Broeders; H.E.M. Spijkers (Ine)

    1989-01-01

    textabstractThe sensitivity of a newly developed enzyme-linked immunosorbent assay (ELISA) for detection of antibody to K virus was compared with the sensitivities of an immunofluorescence assay (IFA) and a hemagglutination inhibition assay (HIA). Specific pathogen-free BALB/c RIVM mice, 5 weeks old

  19. Identification of irradiated pepper with comet assay

    International Nuclear Information System (INIS)

    The treatment of foods with ionizing radiations is a technological process utilized in order to increase the hygienic quality and the storage time of the foods. Several methods of detection of irradiated foods have been recommended. The comet assay of DNA is one fast and economical technique for the qualitative identification of irradiated foods. The objective of the present paper was to identify with the comet assay technique the modifications of the DNA molecule of irradiated pepper storage at environment and refrigeration temperatures and different post-irradiation times for different absorbed dose values, (0.1, 0.3 and 0.5 kGy). It was demonstrated that for the high absorbed dose values was observed a greater break into fragments of the DNA molecule, which shows the application of this technique for the identification of irradiated foods. (author)

  20. Transient expression assays in tobacco protoplasts.

    Science.gov (United States)

    Vanden Bossche, Robin; Demedts, Brecht; Vanderhaeghen, Rudy; Goossens, Alain

    2013-01-01

    The sequence information generated through genome and transcriptome analysis from plant tissues has reached unprecedented sizes. Sequence homology-based annotations may provide hints for the possible function and roles of particular plant genes, but the functional annotation remains nonexistent or incomplete for many of them. To discover gene functions, transient expression assays are a valuable tool because they can be done more rapidly and at a higher scale than generating stably transformed tissues. Here, we describe a transient expression assay in protoplasts derived from suspension cells of tobacco (Nicotiana tabacum) for the study of the transactivation capacities of transcription factors. To enhance throughput and reproducibility, this method can be automated, allowing medium-throughput screening of interactions between large compendia of potential transcription factors and gene promoters.

  1. High-Throughput Cell Toxicity Assays.

    Science.gov (United States)

    Murray, David; McWilliams, Lisa; Wigglesworth, Mark

    2016-01-01

    Understanding compound-driven cell toxicity is vitally important for all drug discovery approaches. With high-throughput screening (HTS) being the key strategy to find hit and lead compounds for drug discovery projects in the pharmaceutical industry [1], an understanding of the cell toxicity profile of hit molecules from HTS activities is fundamentally important. Recently, there has been a resurgence of interest in phenotypic drug discovery and these cell-based assays are now being run in HTS labs on ever increasing numbers of compounds. As the use of cell assays increases the ability to measure toxicity of compounds on a large scale becomes increasingly important to ensure that false hits are not progressed and that compounds do not carry forward a toxic liability that may cause them to fail at later stages of a project. Here we describe methods employed in the AstraZeneca HTS laboratory to carry out very large scale cell toxicity screening. PMID:27317000

  2. Mobile nondestructive assay and examination instruments

    International Nuclear Information System (INIS)

    A compact system that evaluates radioactive materials can furnish a big savings to taxpayers by ensuring that only properly identified nuclear waste is sent to a Department of Energy (DOE) radioactive waste storage area. The Los Alamos National Laboratory's Advanced Nuclear Technology Group has developed and field tested two easily transportable, self-contained modules: one x-rays the contents of special 208-iota shipment containers, the other assays the contents. The assay and evaluation system is a simple, portable solution to a complex problem that ensures that only properly packaged transuranic (TRU) waste is shipped to the Department of Energy's Waste Isolation Pilot Plant (WIPP). Caustic chemicals, liquids, and other objects or materials that could cause a container leak during shipment are the objects of an x-ray and video camera used in the system

  3. Developments in plutonium waste assay at AWE.

    Science.gov (United States)

    Miller, T J

    2009-06-01

    In 2002 a paper was presented at the 43rd Annual Meeting of the Institute of Nuclear Materials Management (INMM) on the assay of low level plutonium (Pu) in soft drummed waste (Miller 2002 INMM Ann. Meeting (Orlando, FL, 23-27 July 2002)). The technique described enabled the Atomic Weapons Establishment (AWE), at Aldermaston in the UK, to meet the stringent Low Level Waste Repository at Drigg (LLWRD) conditions for acceptance for the first time. However, it was initially applied to only low density waste streams because it relied on measuring the relatively low energy (60 keV) photon yield from Am-241 during growth. This paper reviews the results achieved when using the technique to assay over 10,000 waste packages and presents the case for extending the range of application to denser waste streams. PMID:19454791

  4. Developments in plutonium waste assay at AWE

    Energy Technology Data Exchange (ETDEWEB)

    Miller, T J [AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom)], E-mail: Timothy.Miller@awe.co.uk

    2009-06-15

    In 2002 a paper was presented at the 43rd Annual Meeting of the Institute of Nuclear Materials Management (INMM) on the assay of low level plutonium (Pu) in soft drummed waste (Miller 2002 INMM Ann. Meeting (Orlando, FL, 23-27 July 2002)). The technique described enabled the Atomic Weapons Establishment (AWE), at Aldermaston in the UK, to meet the stringent Low Level Waste Repository at Drigg (LLWRD) conditions for acceptance for the first time. However, it was initially applied to only low density waste streams because it relied on measuring the relatively low energy (60 keV) photon yield from Am-241 during growth. This paper reviews the results achieved when using the technique to assay over 10 000 waste packages and presents the case for extending the range of application to denser waste streams.

  5. Nondestructive assay methods for solids containing plutonium

    International Nuclear Information System (INIS)

    Specific nondestructive assay (NDA) methods, e.g. calorimetry, coincidence neutron counting, singles neutron counting, and gamma ray spectrometry, were studied to provide the Savannah River Plant with an NDA method to measure the plutonium content of solid scrap (slag and crucible) generated in the JB-Line plutonium metal production process. Results indicate that calorimetry can be used to measure the plutonium content to within about 3% in 4 to 6 hours by using computerized equilibrium sample power predictive models. Calorimetry results confirm that a bias exists in the present indirect measurement method used to estimate the plutonium content of slag and crucible. Singles neutron counting of slag and crucible can measure plutonium to only +-30%, but coincidence neutron counting methods improve measurement precision to better than +-10% in less than ten minutes. Only four portions of a single slag and crucible sample were assayed, and further study is recommended

  6. Assay of 25-OH vitamin D3

    International Nuclear Information System (INIS)

    A simplified version of the competitive protein-binding assay for 25-OH vitamin D3 (25-OH D3) derived from the method of Belsey et al. is presented. The procedure does not include a chromatographic step, and it is performed on an alcoholic extract of 0.1 ml plasma or serum. Normal rat serum (1:20000) was used as binding protein. No β-lipoproteins were added to the assay buffer. A 10% displacement of the tracer was observed at 0.04 ng/tube and a 50% displacement at 0.15 ng/tube, allowing for the measurement of 25-OH D3 concentrations between 2 ng/ml and 200 ng/ml. Mean values in a normal group were 23.1+-6.5 ng/ml (range 16-37 ng/ml, n=11). (author)

  7. Comparison of LC-MS Assay and HPLC Assay of Busulfan in Clinical Pharmacokinetics Studies

    OpenAIRE

    Hongxia Lin; Susan Goodin; Strair, Roger K.; Robert S. DiPaola; Gounder, Murugesan K.

    2012-01-01

    Busulfan is used in preparative regimens for bone marrow transplantation and timely busulfan plasma concentration reporting is critical for subsequent dose adjustment. We compared two sensitive methods for pharmacokinetics studies including LC-MS assay and HPLC precolumn derivatization assay. Chromatographic separation was performed on a Gemini C18 column. Liquid-liquid extraction with ethyl acetate was used for plasma sample preparation. Busulfan and internal standard ([2H8]-busulfan) were d...

  8. Comet assay on mice testicular cells

    OpenAIRE

    Anoop Kumar Sharma

    2015-01-01

    Heritable mutations may result in a variety of adverse outcomes including genetic disease in the offspring. In recent years the focus on germ cell mutagenicity has increased and the “Globally Harmonized System of Classification and Labelling of Chemicals (GHS)” has published classification criteria for germ cell mutagens (Speit et al., 2009). The in vivo Comet assay is considered a useful tool for investigating germ cell genotoxicity. In the present study DNA strand breaks in testicular cel...

  9. Recent advances in sulfotransferase enzyme activity assays

    OpenAIRE

    Paul, Priscilla; Suwan, Jiraporn; Liu, Jian; Dordick, Jonathan S.; Linhardt, Robert J.

    2012-01-01

    Sulfotransferases are enzymes that catalyze the transfer of sulfo groups from a donor, for example 3′-phosphoadenosine 5′-phosphosulfate, to an acceptor, for example the amino or hydroxyl groups of a small molecule, xenobiotic, carbohydrate, or peptide. These enzymes are important targets in the design of novel therapeutics for treatment of a variety of diseases. This review examines assays used for this important class of enzyme, paying particular attention to sulfotransferases acting on car...

  10. SWEPP assay system software: An update

    International Nuclear Information System (INIS)

    The development of a new software package to control data acquisition and perform data analysis for a Passive/Active Neutron Assay system was reported at this conference in 1994. The software has undergone additional development including improvements to the user interface, additional data integrity checks and support for a shift register coincidence analyzer. An overview of this additional work is presented in this report

  11. A Quantitative Assay for Aggrecanase Activity

    OpenAIRE

    Will, Horst; Dettloff, Matthias; Bendzkô, Peter; Sveshnikov, Peter

    2005-01-01

    Aggrecanase activities of ADAMTS (a disintegrin and metalloproteinase with thrombospondin motifs) proteinases were measured with a recombinant aggrecan fragment and two monoclonal antibodies. Recombinant human aggrecan interglobular domain was first incubated in the presence of ADAMTS enzymes. The aggrecan peptide with the N-terminal sequence ARGSVIL released upon hydrolysis was then quantified in an enzyme-linked immunosorbent assay (ELISA) with an anti-neoepitope antibody specific for the N...

  12. Quantifiable Lateral Flow Assay Test Strips

    Science.gov (United States)

    2003-01-01

    As easy to read as a home pregnancy test, three Quantifiable Lateral Flow Assay (QLFA) strips used to test water for E. coli show different results. The brightly glowing control line on the far right of each strip indicates that all three tests ran successfully. But the glowing test line on the middle left and bottom strips reveal their samples were contaminated with E. coli bacteria at two different concentrations. The color intensity correlates with concentration of contamination.

  13. Two important Saudi crude assays updated

    International Nuclear Information System (INIS)

    This paper reports on updating two important Saudi Arabian crude oils-Arabian Heavy (Safaniya) and Arabian Light-which is part of a continuing series on world export crudes. Arabian Heavy (Safaniya) was reassayed in early 1990; Arabian Light in May 1990. These assays, therefore, replace those that appeared previously. However, as is frequently the case with crudes from major, single reservoirs, there is little, if any, change in their characteristics

  14. Radioligand assay: current trends in automation

    International Nuclear Information System (INIS)

    Using automatic equipment to perform routine RIA procedures can save time and money, improve precision, and free technologists to work on more-complex, non-routine assays. This article examines some of the instruments available for semiautomated and fully automated RIA testing. The pros and cons of automated testing are explored, and a framework for judging the true value and limitations of systems is presented

  15. Methods and devices for protein assays

    Energy Technology Data Exchange (ETDEWEB)

    Chhabra, Swapnil (San Jose, CA); Cintron, Jose M. (Indianapolis, IN); Shediac, Renee (Oakland, CA)

    2009-11-03

    Methods and devices for protein assays based on Edman degradation in microfluidic channels are disclosed herein. As disclosed, the cleaved amino acid residues may be immobilized in an array format and identified by detectable labels, such as antibodies, which specifically bind given amino acid residues. Alternatively, the antibodies are immobilized in an array format and the cleaved amino acids are labeled identified by being bound by the antibodies in the array.

  16. Hyperpolarized NMR Probes for Biological Assays

    Directory of Open Access Journals (Sweden)

    Sebastian Meier

    2014-01-01

    Full Text Available During the last decade, the development of nuclear spin polarization enhanced (hyperpolarized molecular probes has opened up new opportunities for studying the inner workings of living cells in real time. The hyperpolarized probes are produced ex situ, introduced into biological systems and detected with high sensitivity and contrast against background signals using high resolution NMR spectroscopy. A variety of natural, derivatized and designed hyperpolarized probes has emerged for diverse biological studies including assays of intracellular reaction progression, pathway kinetics, probe uptake and export, pH, redox state, reactive oxygen species, ion concentrations, drug efficacy or oncogenic signaling. These probes are readily used directly under natural conditions in biofluids and are often directly developed and optimized for cellular assays, thus leaving little doubt about their specificity and utility under biologically relevant conditions. Hyperpolarized molecular probes for biological NMR spectroscopy enable the unbiased detection of complex processes by virtue of the high spectral resolution, structural specificity and quantifiability of NMR signals. Here, we provide a survey of strategies used for the selection, design and use of hyperpolarized NMR probes in biological assays, and describe current limitations and developments.

  17. Design of radiation dose tumor response assays

    International Nuclear Information System (INIS)

    The efficient utilization of animals in a radiation dose response assay for tumor control requires a definition of the goal, e.g., TCD50 or slope. A series of computer modelled ''experiments'' have been performed for each of a number of allocations of dose levels (DL) and number of animals/DL. The authors stipulated that the assumed TCD50 was .85 of true value; assumed slope was correct. They stipulated a binominal distribution of observed tumor control results at each dose level. A pilot assay used 6 tumors at 7 DL (from TCD1-TCD97). The second assay used 30 tumors assigned to 2,3,5 or 9 DL and to selected tumor control probabilities (TCP derived from the pilot run. Results from 100 test runs were combined with the pilot run for each of the combination of DL and TCP values. Logit regression lines were fitted through these ''data'' and the 95% CL around the TCD50 and the TCD37 values and the variances of the slopes were computed. These experiments were repeated using the method suggested by Porter (1980). Results show that a different strategy is needed depending upon the goal, viz. TCD50 or TCD37 vs slope. The differences between the two approaches are discussed

  18. Diagnostic Certified Assay: Neuromuscular and Cardiac Assessments

    Directory of Open Access Journals (Sweden)

    Rea Valaperta

    2013-01-01

    Full Text Available The expansion of the specific trinucleotide sequence, [CTG], is the molecular pathological mechanism responsible for the clinical manifestations of DM1. Many studies have described different molecular genetic techniques to detect DM1, but as yet there is no data on the analytical performances of techniques used so far in this disease. We therefore developed and validated a molecular method, “Myotonic Dystrophy SB kit,” to better characterize our DM1 population. 113 patients were examined: 20 DM1-positive, 11 DM1/DM2-negative, and13 DM1-negative/DM2-positive, who had a previous molecular diagnosis, while 69 were new cases. This assay correctly identified 113/113 patients, and all were confirmed by different homemade assays. Comparative analysis revealed that the sensitivity and the specificity of the new kit were very high (>99%. Same results were obtained using several extraction procedures and different concentrations of DNA. The distribution of pathologic alleles showed a prevalence of the “classical” form, while of the 96 nonexpanded alleles 19 different allelic types were observed. Cardiac and neuromuscular parameters were used to clinically characterize our patients and support the new genetic analysis. Our findings suggest that this assay appears to be a very robust and reliable molecular test, showing high reproducibility and giving an unambiguous interpretation of results.

  19. Quality control of antibodies for assay development.

    Science.gov (United States)

    Schumacher, Sarah; Seitz, Harald

    2016-09-25

    Antibodies are used as powerful tools in basic research, for example, in biomarker identification, and in various forms for diagnostics, for example, identification of allergies or autoimmune diseases. Due to their robustness and ease of handling, immunoassays are favourite methods for investigation of various biological or medical questions. Nevertheless in many cases, additional analyses such as mass spectrometry are used to validate or confirm the results of immunoassays. To minimize the workload and to increase confidence in immunoassays, there are urgent needs for antibodies which are both highly specific and well validated. Unfortunately many commercially available antibodies are neither well characterized nor fully tested for cross-reactivities. Adequate quality control and validation of an antibody is time-consuming and can be frustrating. Such validation needs to be performed for every assay/application. However, where an antibody validation is successful, a highly specific and stable reagent will be on hand. This article describes the validation processes of antibodies, including some often neglected factors, as well as unspecific binding to other sample compounds in a multiparameter diagnostic assay. The validation consists of different immunological methods, with important assay controls, and is performed in relation to the development of a diagnostic test. PMID:26873787

  20. Prospects for cellular mutational assays in human populations

    International Nuclear Information System (INIS)

    Practical, sensitive, and effective human cellular assays for detecting somatic and germinal mutations would have great value in environmental mutagenesis and carcinogenesis studies. Such assays would fill the void between human mutagenicity and the data that exist from short-term tests and from mutagenicity in other species. This paper discusses the following possible human cellular assays: (1) HPRT (hypoxanthine phosphoribosyltransferase) somatic cell mutation based on 6-thioguanine resistance; (2) hemoglobin somatic cell mutation assay; (3) glycophorin somatic cell mutation assay; and (4) LDH-X sperm cell mutation assay. 18 references

  1. Prospects for cellular mutational assays in human populations

    Energy Technology Data Exchange (ETDEWEB)

    Mendelsohn, M.L.

    1984-06-29

    Practical, sensitive, and effective human cellular assays for detecting somatic and germinal mutations would have great value in environmental mutagenesis and carcinogenesis studies. Such assays would fill the void between human mutagenicity and the data that exist from short-term tests and from mutagenicity in other species. This paper discusses the following possible human cellular assays: (1) HPRT (hypoxanthine phosphoribosyltransferase) somatic cell mutation based on 6-thioguanine resistance; (2) hemoglobin somatic cell mutation assay; (3) glycophorin somatic cell mutation assay; and (4) LDH-X sperm cell mutation assay. 18 references.

  2. Evaluation of Chikungunya diagnostic assays: differences in sensitivity of serology assays in two independent outbreaks.

    Directory of Open Access Journals (Sweden)

    Grace Yap

    Full Text Available BACKGROUND: The sensitivity and specificity of two in-house MAC-ELISA assays were tested and compared with the performance of commercially-available CTK lateral flow rapid test and EUROIMMUN IFA assays for the detection of anti-Chikungunya virus (CHIKV IgM. Each MAC-ELISA assay used a whole virus-based antigen derived from genetically distinct CHIKV strains involved in two chikungunya disease outbreaks in Singapore (2008; a January outbreak strain with alanine at amino acid residue 226 of the E1 glycoprotein (CHIKV-A226 and a May-to-September outbreak strain that possessed valine at the same residue (CHIKV-226V. We report differences in IgM detection efficacy of different assays between the two outbreaks. The sensitivities of two PCR protocols were also tested. METHODS AND FINDINGS: For sera from January outbreak, the average detection threshold of CTK lateral flow test, MAC-ELISAs and EUROIMMUN IFA assays was 3.75, 4.38 and 4.88 days post fever onset respectively. In contrast, IgM detection using CTK lateral flow test was delayed to more than 7 days after fever onset in the second outbreak sera. However, MAC-ELISA using CHIKV-226V detected IgM in the second outbreak sera 3.96 days after fever onset, which was approximately one day earlier compared to the same assay using CHIKV-A226 (4.86 days. Specificity was 100% for both commercial assays, and 95.6% for the in-house MAC-ELISAs. For sensitivity determination of the PCR protocols, the probe-based real time RT-PCR method was found to be 10 times more sensitive than one based on SYBR Green. CONCLUSION: Our findings suggested that the two strains of CHIKV using variants A226 and 226V resulted in variation in sensitivities of the assays evaluated. We postulated that the observed difference in antigen efficacy could be due to the amino acid substitution differences in viral E1 and E2 envelope proteins, especially the E1-A226V substitution. This evaluation demonstrates the importance of appraisal of

  3. Genotoxic effect of gamma radiation in vivo rats as evaluated by comet assay and micronucleus assay

    International Nuclear Information System (INIS)

    DNA is one of the most critical site of damage induced by UV, gamma radiation and other the environmental chemical pollutants. Genotoxic evaluation of environmental agents is generally carried out using cytogenetic markers like chromosomal aberrations, sister chromatid exchanges and micronuclei formation. During the recent years Single Cell Gel Electrophoresis/Comet Assay, has emerged as one of the most powerful assays to detect DNA damage at molecular level in any eukaryotic cell. Present studies were undertaken to investigate the effect of gamma radiation at DNA and chromosomal level using comet assay and micronucleus test. Female Wistar rats were exposed to gamma radiation using 60Co Teletherapy machine; 0.125, 0.25, 0.5 and 1.0 Gy at a dose rate of 0.33 Gy/min. Blood and bone marrow samples were processed for comet assay using the standard protocol. Bone marrow cells from femur bone were also processed for micronucleus assay. Results of these studies indicated a dose dependent increase in DNA damage as indicated by increase in tail length (TL), tail moment (TM) and % DNA in tail (% DNA- T). Similarly, a dose dependent increase in the frequency of micronucleated polychromatic erythrocytes (mn-PCEs) was also observed. A good correlation between, DNA damage and the induction of micronucleated erythrocytes was observed. (author)

  4. Mobile nondestructive assay and examination instruments

    International Nuclear Information System (INIS)

    A compact system that evaluates radioactive materials can furnish a big savings to taxpayers by ensuring that only properly identified nuclear waste is sent to a Department of Energy (DOE) radioactive waste storage area. The Los Alamos National Laboratory's Advanced Nuclear Technology Group has developed and field tested two esily transportable, self-contained modules: one x-rays the contents of special 208-l shipment containers, the other assays the contents. The assay and evaluation system is a simple, portable solution to a complex problem that ensures that only properly packaged transuranic (TRU) wste is shipped to the Department of Energy's Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico. Caustic chemicals, liquids, and other objects or materials tht could cause a container leak during shipment are the objects of an x-ray and video camera used in the system. The camera inspects the contents of 208-l drums that are brought into the system on a conveyor and rotated, one at a time, in front of the x-ray source. Free liquids can be detected by shaking the drum; the sloshing liquid is visible on the video screen. After the drum is x-rayed, it is conveyed to the assay module where precision instruments measure the amounts of TRU isotopes present in the waste. If the drum contains fissile TRU isotopes above the safety limit, it is rejected and sent to an appropriate facility for repackaging; if the drum contains less than the 100 nCi/g lower-level limit for TRU, it is rejected and sent to a low-level nuclear waste burial site. Drums whose contents fall between these limits are accepted and certified for shipment to the WIPP. Made to fit on flatbed trailers, the entire system can be transported to a DOE facility and be ready for operations within 5 hours after arrival

  5. Test procedure for boxed waste assay system

    International Nuclear Information System (INIS)

    This document, prepared by Los Alamos National Laboratory's NMT-4 group, details the test methodology and requirements for Acceptance/Qualification testing of a Boxed Waste Assay System (BWAS) designed and constructed by Pajarito Scientific Corporation. Testing of the BWAS at the Plutonium Facility (TA55) at Los Alamos National Laboratory will be performed to ascertain system adherence to procurement specification requirements. The test program shall include demonstration of conveyor handling capabilities, gamma ray energy analysis, and imaging passive/active neutron accuracy and sensitivity. Integral to these functions is the system's embedded operating and data reduction software

  6. Protein kinase profiling assays: a technology review.

    Science.gov (United States)

    Wang, Yuren; Ma, Haiching

    2015-11-01

    Protein kinases have become one of the most intensively pursued classes of drug targets for many diseases such as cancers and inflammatory diseases. Kinase profiling work seeks to understand general selectivity trends of lead compounds across the kinome, which help with target selection, compound prioritization, and potential implications in toxicity. Under the current drug discovery process, screening of compounds against comprehensive panels of kinases and their mutants has become the standard approach. Many screening assays and technologies which are compatible for high-throughput screening (HTS) against kinases have been extensively pursued and developed.

  7. A New Version of Comet assay

    OpenAIRE

    I.A. Chernigina; T.G. Shcherbatyuk

    2016-01-01

    The aim of the investigation was to assess the availability of ozone to induce DNA damage in individual cells when analyzing them using the Comet assay. Materials and Methods. Experimental studies were performed on whole blood leukocytes of white non-linear intact male rats (n=16) weighing 250±25 g. Two series of experiments were made to induce DNA damage in leukocytes. During the first series the samples were exposed to gamma-radiation, and during the second series the slides wer...

  8. Lipase turbidimetric assay and acute pancreatitis.

    Science.gov (United States)

    Orda, R; Orda, S; Baron, J; Wiznitzer, T

    1984-04-01

    The simplified turbidimetric assay for lipase activity was used for the differential diagnosis of acute pancreatitis. Serum lipase levels were found to be increased in a group of 17 patients in whom acute pancreatitis was clinically suspected and confirmed by a high ACCR and decreased uptake of the radionuclide in the pancreas scan. The lipase levels were within normal limits in a control group of 14 patients suffering from diseases other than acute pancreatitis. The turbidimetric test was helpful for rapid quantitative determination of serum lipase and thus for the early and accurate diagnosis of acute pancreatitis. PMID:6200277

  9. Radioactive waste package assay facility. Volume 1. Application of assay technology

    International Nuclear Information System (INIS)

    This report, in three volumes, covers the work carried out by Taylor Woodrow Construction Ltd., and two major sub-contractors: Harwell Laboratory (AEA Technology) and Siemens Plessey Controls Ltd., on the development of a radioactive waste package assay facility, for cemented 500 litre intermediate level waste drums. In volume 1, the reasons for assay are considered together with the various techniques that can be used, and the information that can be obtained. The practical problems associated with the use of the various techniques in an integrated assay facility are identified, and the key parameters defined. Engineering and operational features are examined and provisional designs proposed for facilities at three throughput levels: 15,000, 750 and 30 drums per year respectively. The capital and operating costs for such facilities have been estimated. A number of recommendations are made for further work. 16 refs., 14 figs., 13 tabs

  10. Assay Method for 235U in Low-Density Waste

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>235U assay method will provide a semi-quantitative assay for any uranium lumps that might exist in low-density, low-Z material waste boxes within a short count time. These materials will consist of

  11. Clinical Assay Development Support - Office of Cancer Clinical Proteomics Research

    Science.gov (United States)

    The NCI’s Division of Cancer Treatment and Diagnosis and the Cancer Diagnosis Program announce a request for applications for the Clinical Assay Development Program (CADP) for investigators seeking clinical assay development and validation resources.

  12. Assaying environmental nickel toxicity using model nematodes

    Science.gov (United States)

    Rudel, David; Douglas, Chandler; Huffnagle, Ian; Besser, John M.; Ingersoll, Christopher G.

    2013-01-01

    Although nickel exposure results in allergic reactions, respiratory conditions, and cancer in humans and rodents, the ramifications of excess nickel in the environment for animal and human health remain largely undescribed. Nickel and other cationic metals travel through waterways and bind to soils and sediments. To evaluate the potential toxic effects of nickel at environmental contaminant levels (8.9-7,600 µg Ni/g dry weight of sediment and 50-800 µg NiCl2/L of water), we conducted assays using two cosmopolitan nematodes, Caenorhabditis elegans and Pristionchus pacificus. We assayed the effects of both sediment-bound and aqueous nickel upon animal growth, developmental survival, lifespan, and fecundity. Uncontaminated sediments were collected from sites in the Midwestern United States and spiked with a range of nickel concentrations. We found that nickel-spiked sediment substantially impairs both survival from larval to adult stages and adult longevity in a concentration-dependent manner. Further, while aqueous nickel showed no adverse effects on either survivorship or longevity, we observed a significant decrease in fecundity, indicating that aqueous nickel could have a negative impact on nematode physiology. Intriguingly, C. elegansand P. pacificus exhibit similar, but not identical, responses to nickel exposure. Moreover, P. pacificus could be tested successfully in sediments inhospitable to C. elegans. Our results add to a growing body of literature documenting the impact of nickel on animal physiology, and suggest that environmental toxicological studies could gain an advantage by widening their repertoire of nematode species.

  13. Standardization of anti-DNA antibody assays.

    Science.gov (United States)

    Pisetsky, David S

    2013-07-01

    Antibodies to DNA (anti-DNA) are the serological hallmark of systemic lupus erythematosus and represent important biomarkers for clinical and research purposes. These antibodies are part of a family of antibodies to nucleosomes and bind to conserved sites widely present on DNA. While the value of anti-DNA as a biomarker is well established, the assay for these antibodies has involved a variety of DNA sources and systems to detect DNA-anti-DNA interactions. The influence of these variations on antibody detection has complicated assay standardization. As an antigen, DNA has unique features since it is a highly charged polymer that has structural heterogeneity. This heterogeneity can affect antigenicity which can vary on the basis of DNA origin, size, conformation and mobility. In addition, as a polymer, DNA can promote patterns of antibody binding based on monogamous or bivalent interaction which require an extended polynucleotide structure. Understanding the nature of DNA as an antigen can facilitate interpretation of serological tests and underpin efforts at better standardization.

  14. Rapid Multiple Immunoenzyme Assay of Mycotoxins

    Directory of Open Access Journals (Sweden)

    Alexandr E. Urusov

    2015-01-01

    Full Text Available Mycotoxins are low molecular weight fungal metabolites that pose a threat as toxic contaminants of food products, thereby necessitating their effective monitoring and control. Microplate ELISA can be used for this purpose, but this method is characteristically time consuming, with a duration extending to several hours. This report proposes a variant of the ELISA method for the detection and quantification of three mycotoxins, ochratoxin A, aflatoxin B1 and zearalenone, in the kinetic regime. The main requirement for the proposed kinetic protocol was to provide a rapid method that combined sensitivity and accuracy. The use of biotin with an extended spacer together with a streptavidin–polyperoxidase conjugate provided high signal levels, despite these interactions occurring under non-equilibrium conditions. Duration of the individual mycotoxin assays was 20 min, whereas the analysis of all three mycotoxins in parallel reached a maximum duration of 25 min. Recovery of at least 95% mycotoxins in water-organic extracts was shown. The developed assays were successfully validated using poultry processing products and corn samples spiked with known quantities of mycotoxins. The detection limits for aflatoxin B1, ochratoxin A and zearalenone in these substances were 0.24, 1.2 and 3 ng/g, respectively.

  15. High Throughput Danio Rerio Energy Expenditure Assay.

    Science.gov (United States)

    Williams, Savannah Y; Renquist, Benjamin J

    2016-01-01

    Zebrafish are an important model organism with inherent advantages that have the potential to make zebrafish a widely applied model for the study of energy homeostasis and obesity. The small size of zebrafish allows for assays on embryos to be conducted in a 96- or 384-well plate format, Morpholino and CRISPR based technologies promote ease of genetic manipulation, and drug treatment by bath application is viable. Moreover, zebrafish are ideal for forward genetic screens allowing for novel gene discovery. Given the relative novelty of zebrafish as a model for obesity, it is necessary to develop tools that fully exploit these benefits. Herein, we describe a method to measure energy expenditure in thousands of embryonic zebrafish simultaneously. We have developed a whole animal microplate platform in which we use 96-well plates to isolate individual fish and we assess cumulative NADH2 production using the commercially available cell culture viability reagent alamarBlue. In poikilotherms the relationship between NADH2 production and energy expenditure is tightly linked. This energy expenditure assay creates the potential to rapidly screen pharmacological or genetic manipulations that directly alter energy expenditure or alter the response to an applied drug (e.g. insulin sensitizers). PMID:26863590

  16. A New Version of Comet Assay

    Directory of Open Access Journals (Sweden)

    I.A. Chernigina

    2016-03-01

    Full Text Available The aim of the investigation was to assess the availability of ozone to induce DNA damage in individual cells when analyzing them using the Comet assay. Materials and Methods. Experimental studies were performed on whole blood leukocytes of white non-linear intact male rats (n=16 weighing 250±25 g. Two series of experiments were made to induce DNA damage in leukocytes. During the first series the samples were exposed to gamma-radiation, and during the second series the slides were treated with ozonized phosphate buffer saline. Further the cells were exposed to cytolysis followed by DNA denaturation, electrophoresis, neutralization, DNA being stained with a SYBR GREEN I. Comet visualization (fluorescent microscopy and scoring were performed. Results. The new version of the Comet assay was developed. Ozone concentration, 900 µg/L, in ozone-oxygen mixture, and the exposure time for 10 min on the cells on a microscope slides were found to be optimal for detection of DNA damage and its analysis. In addition, ozone application enables to minimize the drawbacks and limitations of gamma-radiation source.

  17. A new chemical assay standard for plutonium

    International Nuclear Information System (INIS)

    This paper reports on a study of the structural and thermal aspects of alkali metal double sulfates of plutonium has led to a new chemical assay standard for plutonium, K4Pu(SO4)4. The compound is obtained by dehydration of the dihydrate, K4Pu(SO4)4 · 2H2O. Anhydrous K4Pu(SO4)4 was evaluated for its purity, solubility, stoichiometry, and stability for a 2-year period. Chemical analyses for plutonium and sulfate and emission spectrographic and mass spectrometric analyses for impurity elements showed that the compound is stoichiometric, with a total impurity content of less than 250 ppm. Analysis for plutonium in store samples confirmed that the product is stable to α-radiolytic and atmospheric conditions and that it decomposes only above 700 degrees C. The evaluations done on preparations of up to 100 g per batch favor its selection as a better chemical assay standard for plutonium than Pu(SO4)2·4H2O

  18. Two Types of Assays for Detecting Frog Sperm Chemoattraction

    OpenAIRE

    Burnett, Lindsey A.; Tholl, Nathan; Chandler, Douglas E.

    2011-01-01

    Sperm chemoattraction in invertebrates can be sufficiently robust that one can place a pipette containing the attractive peptide into a sperm suspension and microscopically visualize sperm accumulation around the pipette1. Sperm chemoattraction in vertebrates such as frogs, rodents and humans is more difficult to detect and requires quantitative assays. Such assays are of two major types - assays that quantitate sperm movement to a source of chemoattractant, so-called sperm accumulation assay...

  19. The JaCVAM / OECD activities on the comet assay

    OpenAIRE

    Hajime Kojima

    2015-01-01

    The in vivo alkaline single cell gel electrophoresis assay, also called alkaline comet assay is a method measuring DNA strand breaks in eukaryotic cells. This assay was adopted in the Organisation for Economic Co-operation and Development (OECD) Test guideline (TG) 489 on September 26, 2014. This TG is part of a series of TGs on genetic toxicology. A formal validation trial of the this assay was performed in 2006-2012, coordinated by the Japanese Center for the Validation of Alternative...

  20. Assay optimization: a statistical design of experiments approach.

    Science.gov (United States)

    Altekar, Maneesha; Homon, Carol A; Kashem, Mohammed A; Mason, Steven W; Nelson, Richard M; Patnaude, Lori A; Yingling, Jeffrey; Taylor, Paul B

    2007-03-01

    With the transition from manual to robotic HTS in the last several years, assay optimization has become a significant bottleneck. Recent advances in robotic liquid handling have made it feasible to reduce assay optimization timelines with the application of statistically designed experiments. When implemented, they can efficiently optimize assays by rapidly identifying significant factors, complex interactions, and nonlinear responses. This article focuses on the use of statistically designed experiments in assay optimization.

  1. Performance Characteristics of Xpert Flu/RSV XC Assay.

    Science.gov (United States)

    Popowitch, Elena B; Miller, Melissa B

    2015-08-01

    The Xpert Flu/RSV XC assay was compared to laboratory-developed tests (LDTs) (n = 207) and the Xpert Flu assay (n = 147) using archived nasopharyngeal swabs. The percentages of positive agreements with LDTs were 97.8% for influenza A, 97.2% for influenza B, and 89.3% for RSV. The sensitivity of influenza detection was improved with the Xpert Flu/RSV XC assay compared to the Xpert Flu assay. PMID:26019209

  2. Performance Characteristics of Xpert Flu/RSV XC Assay.

    Science.gov (United States)

    Popowitch, Elena B; Miller, Melissa B

    2015-08-01

    The Xpert Flu/RSV XC assay was compared to laboratory-developed tests (LDTs) (n = 207) and the Xpert Flu assay (n = 147) using archived nasopharyngeal swabs. The percentages of positive agreements with LDTs were 97.8% for influenza A, 97.2% for influenza B, and 89.3% for RSV. The sensitivity of influenza detection was improved with the Xpert Flu/RSV XC assay compared to the Xpert Flu assay.

  3. Comparison of two rapid assays for Clostridium difficile Common antigen and a C difficile toxin A/B assay with the cell culture neutralization assay.

    Science.gov (United States)

    Reller, Megan E; Alcabasa, Romina C; Lema, Clara A; Carroll, Karen C

    2010-01-01

    We compared 3 rapid assays for Clostridium difficile with a cell culture cytotoxicity neutralization assay (CCNA). Of 600 stool samples, 46 were positive for toxigenic C difficile. Both rapid common antigen assays were highly sensitive (91.3%-100%) and, therefore, were appropriate screening tests. The rapid toxin assay had poor sensitivity (61%) but excellent specificity (99.3%). Testing stools for glutamate dehydrogenase (step 1) and those positive with a rapid toxin assay (step 2) would correctly classify 81% of submitted specimens within 2 hours, including during periods of limited staffing (evenings, nights, and weekends). CCNA could then be used as a third step to test rapid toxin-negative samples, thereby providing a final result for the remaining 19% of samples by 48 to 72 hours. The use of rapid assays as outlined could enhance timely diagnosis of C difficile. PMID:20023265

  4. Comparison of two rapid assays for Clostridium difficile Common antigen and a C difficile toxin A/B assay with the cell culture neutralization assay.

    Science.gov (United States)

    Reller, Megan E; Alcabasa, Romina C; Lema, Clara A; Carroll, Karen C

    2010-01-01

    We compared 3 rapid assays for Clostridium difficile with a cell culture cytotoxicity neutralization assay (CCNA). Of 600 stool samples, 46 were positive for toxigenic C difficile. Both rapid common antigen assays were highly sensitive (91.3%-100%) and, therefore, were appropriate screening tests. The rapid toxin assay had poor sensitivity (61%) but excellent specificity (99.3%). Testing stools for glutamate dehydrogenase (step 1) and those positive with a rapid toxin assay (step 2) would correctly classify 81% of submitted specimens within 2 hours, including during periods of limited staffing (evenings, nights, and weekends). CCNA could then be used as a third step to test rapid toxin-negative samples, thereby providing a final result for the remaining 19% of samples by 48 to 72 hours. The use of rapid assays as outlined could enhance timely diagnosis of C difficile.

  5. 21 CFR 864.7470 - Glycosylated hemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Glycosylated hemoglobin assay. 864.7470 Section... Glycosylated hemoglobin assay. (a) Identification. A glycosylated hemoglobin assay is a device used to measure the glycosylated hemoglobins (A1a, A1b, and A1c) in a patient's blood by a column...

  6. 21 CFR 866.3402 - Plasmodium species antigen detection assays.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plasmodium species antigen detection assays. 866... Plasmodium species antigen detection assays. (a) Identification. A Plasmodium species antigen detection assay... malaria caused by the four malaria species capable of infecting humans: Plasmodium falciparum,...

  7. Assay for mutagenesis in heterozygous diploid human lymphoblasts

    Science.gov (United States)

    Skopek, Thomas R.; Liber, Howard L.; Penman, Bruce W.; Thilly, William G.; Hoppe, IV, Henry

    1981-01-01

    An assay is disclosed for determining mutagenic damage caused by the administration of a known or suspected mutagen to diploid human lymphoblastoid cell lines. The gene locus employed for this assay is the gene for thymidine kinase, uridine kinase, or cytidine deaminase. Since human lymphoblastoid cells contain two genes for these enzymes, heterozygotes of human lymphoblastoid cells are used in this assay.

  8. 21 CFR 866.2350 - Microbiological assay culture medium.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Microbiological assay culture medium. 866.2350... Microbiological assay culture medium. (a) Identification. A microbiological assay culture medium is a device that... (general controls). The device is exempt from the premarket notification procedures in subpart E of...

  9. 21 CFR 864.7415 - Abnormal hemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Abnormal hemoglobin assay. 864.7415 Section 864.7415 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... hemoglobin assay. (a) Identification. An abnormal hemoglobin assay is a device consisting of the...

  10. 21 CFR 864.7400 - Hemoglobin A2 assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hemoglobin A2 assay. 864.7400 Section 864.7400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... assay. (a) Identification. A hemoglobin A2 assay is a device used to determine the hemoglobin A2...

  11. Assessment and reduction of comet assay variation in relation to DNA damage: studies from the European Comet Assay Validation Group.

    OpenAIRE

    Moller, Peter; Moller, Lennart; Godschalk, Roger W. L.; Jones, George D. D.

    2010-01-01

    The alkaline single cell gel electrophoresis (comet) assay has become a widely used method for the detection of DNA damage and repair in cells and tissues. Still, it has been difficult to compare results from different investigators because of differences in assay conditions and because the data are reported in different units. The European Comet Assay Validation Group (ECVAG) was established for the purpose of validation of the comet assay with respect to measures of DNA damage formation and...

  12. Localized irradiations, Evaluation through ''comet assay''

    International Nuclear Information System (INIS)

    During the last 50 years various radiation accidents involving localized irradiations occurred, resulting mainly from improper handling of sealed sources Co60, Cs137 or Ir192 at workplaces for industrial gammagraphy. Severe skin reaction may develop at the contact sites. Such inhomogeneous irradiations lead to a differential exposure of lymphocytes in lymphatic tissues or other organs that may recirculate into the peripheral blood producing a mixed irradiated and unirradiated population of lymphocytes. Applying the mathematical models ''Contaminated Poisson'' of Dolphin and Qdr method of Sasaki, a mean dose in the irradiated body area and its size can be estimated from unstable chromosome aberration scoring. This give an indication of the proportion of haemopoietic stem cell compartment involved in the overexposure. There are also different biophysical techniques that can give responses in biological dosimetry. The ''Comet Assay'' (single cell gel electrophoresis) is a sensitive and rapid method for DNA strand break detection in individual cells. The advantages of the technique include: collection of data at the level of individual cell; the need for small numbers of cells per sample; its sensitivity for detecting DNA damage and that virtually any eukaryote cell population is amenable to analysis. The objective of this work is to apply ''Comet Assay'' method to evaluate the effect of radiation on skin and subcutaneous tissues, differentiating irradiated from unirradiated body areas. It could provide a useful tool to estimate the extension and the dose in the irradiated region, contributing with the current techniques. In this first study, we evaluate the alkaline comet assay as a method for detection of DNA radiation induced damage in keratinocytes from primary culture obtained from full thickness skin biopsies of patients requiring grafts. Skin and, particularly, keratinocytes were selected as an appropriate cellular system due to: Skin, the first barrier against

  13. Ovariectomized mouse uterotrophic assay of 36 chemicals.

    Science.gov (United States)

    Ohta, Ryo; Takagi, Atsuya; Ohmukai, Hideo; Marumo, Hideki; Ono, Atsushi; Matsushima, Yuko; Inoue, Tohru; Ono, Hiroshi; Kanno, Jun

    2012-01-01

    The concern over endocrine disruptors prompted international establishment of a strategic framework for the identification of the estrogenic compounds. OECD has launched the Conceptual Framework tool box containing various screening and testing methods including the uterotrophic assay. The (anti)estrogenicity of 36 chemicals suspected to be estrogen-receptor interactive by in silico and/or in vitro screening in the Extended Scheme for Endocrine Disruptor Screening and Testing of the Ministry of Health, Labour and Welfare, Japan, were monitored by the uterotrophic assay using C57BL/6J ovariectomized adult female mice after a 7-day exposure by oral gavage (po) and subcutaneous injection (sc). Ethynyl estradiol was used as reference for agonist and antagonist detection. In addition, Bisphenol A (sc) and Genistein (po) were tested for the comparison to rat assays. Among the 36, 2-[Bis(4-hydroxy-phenyl)methyl]benzylalcohol, 2,2',4,4'-Tetrahydroxybenzophenone, 2,4-Dihydroxybenzophenone, 3,3',5-Triiodothyroacetic acid, New fuchsin and alpha-Naphtholbenzein, showed both estrogenic agonistic and antagonistic activities; first two showed U-shaped dose-response in antagonistic studies. N,N-Diphenyl-p-phenylenediamine, 2,2'-Dihydroxy-4,4'-dimethoxybenzophenone, n-Butyl 4-hydroxybenzoate, and Reserpine were agonistic by sc. Benzo [a] pyrene, Benz [a] anthracene, Dibenz [a,h] anthracene, 2-(2H-Benzotriazol-2-yl)-4,6-di(t-pentyl)phenol, Rosemarinic acid, meta-Thymol, 6-Gingerol, Colchicine, Malachite green base, Fenbuconazole, and Lead acetate were antagonistic. The rest, i.e. n-Heptyl 4-hydroxybenzoate, Tetrazolium violet, Pravastatin sodium salt, Physostigmine, salicylate (1:1), Nordihydroguaiaretic acid, o-Cresolphthalein, 1,3-Dinitrobenzene, C.I. Pigment orange, Tetrabromobis-phenol-A, 2-Hydroxy-4-methoxybenzophenone, Ethylparaben, Propyl p-hydroxybenzoate, Kaempferol, 2-(2-Benzotriazolyl)-p-cresol and Phenolphthalein were negative for both effects. Taking together with in

  14. Lateral-Flow Assay for Rapid Serodiagnosis of Human Leptospirosis

    OpenAIRE

    Smits, Henk L.; Eapen, C. K.; Sugathan, Sheela; Kuriakose, Mariamma; Gasem, M. Hussein; Yersin, Claude; Sasaki, David; Pujianto, Bambang; Vestering, Marc; Abdoel, Theresia H.; Gussenhoven, George C.

    2001-01-01

    An assay device for the rapid detection of Leptospira-specific immunoglobulin M (IgM) antibodies in human sera is presented. The sensitivity (85.8%) and specificity (93.6%) of the assay compared well (91.9% agreement) with those of an IgM enzyme-linked immunosorbent assay routinely used in the serodiagnosis of leptospirosis. The sensitivity of the assay varied with the stage of the disease. The assay uses stabilized components and is simply performed by the addition of serum and sample fluid ...

  15. Assays for investigating deSUMOylation enzymes.

    Science.gov (United States)

    Madu, Ikenna G; Chen, Yuan

    2012-07-01

    Post-translational modifications by the SUMO (Small Ubiquitin-like MOdifier) family of proteins are recently discovered essential regulatory mechanisms. All SUMO proteins are synthesized as larger precursors that are matured by SUMO-specific proteases, known as SENPs, which remove several C-terminal amino acids of SUMO to expose the Gly-Gly motif. SENPs also remove SUMO modifications from target proteins, making this modification highly dynamic. At least six deSUMOylation enzymes, all of which are encoded by essential genes, have been identified in mammals. SENP1 has been shown to play an important role in the development of prostate cancer and in angiogenesis. This unit describes and discusses methods for characterizing the deSUMOylation enzymes. These assays enable the identification of inhibitors of these enzymes and investigation of their mechanism of inhibition in order to develop research tools and future therapeutics.

  16. COMPARATIVE STUDY ON MILK CASEIN ASSAY METHODS

    Directory of Open Access Journals (Sweden)

    RODICA CĂPRIłĂ

    2013-12-01

    Full Text Available Casein, the main milk protein was determined by different assay methods: the gravimetric method, the method based on the neutralization of the NaOH excess used for the casein precipitate solving and the method based on the titration of the acetic acid used for the casein precipitation. The last method is the simplest one, with the fewer steps, and also with the lowest error degree. The results of the experiment revealed that the percentage of casein from the whole milk protein represents between 72.6–81.3% in experiment 1, between 73.6–81.3% in experiment 2 and between 74.3–81% in experiment 3.

  17. Stable isotope dilution assays in mycotoxin analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rychlik, Michael; Asam, Stefan [Universitaet Muenchen, Lehrstuhl fuer Lebensmittelchemie der Technischen, Garching (Germany)

    2008-01-15

    The principle and applications of stable isotope dilution assays (SIDAs) in mycotoxin analysis are critically reviewed. The general section includes historical aspects of SIDAs, the prerequisites and limitations of the use of stable isotopically labelled internal standards, and possible calibration procedures. In the application section actual SIDAs for the analysis of trichothecenes, zearalenone, fumonisins, patulin, and ochratoxin A are presented. The syntheses and availability of labelled mycotoxins for use as internal standards is reviewed and specific advances in food analysis and toxicology are demonstrated. The review indicates that LC-MS applications, in particular, require the use of stable isotopically labelled standards to compensate for losses during clean-up and for discrimination due to ion suppression. As the commercial availability of these compounds continues to increase, SIDAs can be expected to find expanding use in mycotoxin analysis. (orig.)

  18. Nondestructive Assay Options for Spent Fuel Encapsulation

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jansson, Peter [Uppsala Univ. (Sweden)

    2014-10-02

    This report describes the role that nondestructive assay (NDA) techniques and systems of NDA techniques may have in the context of an encapsulation and deep geological repository. The potential NDA needs of an encapsulation and repository facility include safeguards, heat content, and criticality. Some discussion of the facility needs is given, with the majority of the report concentrating on the capability and characteristics of individual NDA instruments and techniques currently available or under development. Particular emphasis is given to how the NDA techniques can be used to determine the heat production of an assembly, as well as meet the dual safeguards needs of 1) determining the declared parameters of initial enrichment, burn-up, and cooling time and 2) detecting defects (total, partial, and bias). The report concludes with the recommendation of three integrated systems that might meet the combined NDA needs of the encapsulation/repository facility.

  19. NWAS. Developments for passive uranium assay system

    International Nuclear Information System (INIS)

    We developed uranium mass assay systems for 200-litter wastes drums applied neutron and gamma measurements by NDA method. The systems are composed of the 16 pieces of Helium-3 proportional counters for neutron detection with 100mm thickness polyethylene and a Ge-SSD for gamma ray detection. The neutron measurement methodology is consist of U-234 (α,n) reaction and gamma measurement is applied by Ge-SSD. The extensive testing trials using the known amount of uranium with different enrichment and some kinds of matrices in drums were performed. By using this system we tried to determine uranium mass in drums for the purpose of reduction MUF in URCP. (author)

  20. Universal fieldable assay with unassisted visual detection

    Science.gov (United States)

    Chelyapov, Nicolas (Inventor)

    2012-01-01

    A universal detection system based on allosteric aptamers, signal amplification cascade, and eye-detectable phrase transition. A broadly applicable homogeneous detection system is provided. It utilizes components of the blood coagulation cascade in the presence of polystyrene microspheres (MS) as a signal amplifier. Russell's viper venom factor X activator (RVV-X) triggers the cascade, which results in an eye-visible phase transition--precipitation of MS bound to clotted fibrin. An allosteric RNA aptamer, RNA132, with affinity for RVV-X and human vascular endothelial growth factor (VEGF.sub.165) was created. RNA132 inhibits enzymatic activity of RVV-X. The effector molecule, VEGF.sub.165, reverses the inhibitory activity of RNA132 on RVV-X and restores its enzymatic activity, thus triggering the cascade and enabling the phase transition. Similar results were obtained for another allosteric aptamer modulated by a protein tyrosine phosphatase. The assay is instrumentation-free for both processing and readout.

  1. Thyroglobulin measurement by highly sensitive assays

    DEFF Research Database (Denmark)

    Giovanella, Luca; Feldt-Rasmussen, Ulla; Verburg, Frederik A;

    2015-01-01

    Differentiated thyroid cancer (DTC) is the most common endocrine cancer and its incidence has increased in recent decades. The initial treatment consists of total thyroidectomy followed by ablation of thyroid remnants by radioiodine in most cases. As thyroid cells are the only source of thyroglob......Differentiated thyroid cancer (DTC) is the most common endocrine cancer and its incidence has increased in recent decades. The initial treatment consists of total thyroidectomy followed by ablation of thyroid remnants by radioiodine in most cases. As thyroid cells are the only source...... of thyroglobulin (Tg), circulating Tg serves as a biochemical marker of persistent or recurrent disease in the follow-up of DTC. Due to the suboptimal clinical detection rate of older Tg assays endogenous or exogenous thyrotropin (TSH) stimulations are recommended for unmasking occult disease. However...... importance for both clinical thyroidologists, laboratory physicians and scientists involved in the care of DTC patients....

  2. Analyte detection using an active assay

    Science.gov (United States)

    Morozov, Victor; Bailey, Charles L.; Evanskey, Melissa R.

    2010-11-02

    Analytes using an active assay may be detected by introducing an analyte solution containing a plurality of analytes to a lacquered membrane. The lacquered membrane may be a membrane having at least one surface treated with a layer of polymers. The lacquered membrane may be semi-permeable to nonanalytes. The layer of polymers may include cross-linked polymers. A plurality of probe molecules may be arrayed and immobilized on the lacquered membrane. An external force may be applied to the analyte solution to move the analytes towards the lacquered membrane. Movement may cause some or all of the analytes to bind to the lacquered membrane. In cases where probe molecules are presented, some or all of the analytes may bind to probe molecules. The direction of the external force may be reversed to remove unbound or weakly bound analytes. Bound analytes may be detected using known detection types.

  3. Development of a Radioactive Waste Assay System

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Duck Won; Song, Myung Jae; Shin, Sang Woon; Sung, Kee Bang; Ko, Dae Hach [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Kim, Kil Jeong; Park, Jong Mook; Jee, Kwang Yoong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated at nuclear power plants prior to disposal sites.Individual history records of the radioactive waste should be contained the information about the activity of nuclides in the drum, total activity, weight, the type of waste. A fully automated nuclide analysis assay system, non-destructive analysis and evaluation system of the radioactive waste, was developed through this research project. For the nuclides that could not be analysis directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then scaling factors were used to calculate the activities of {alpha}, {beta}-emitters. Furthermore, this system can automatically mark the analysis results onto the drum surface. An automated drum handling system developed through this research project can reduce the radiation exposure to workers. (author). 41 refs., figs.

  4. High throughput assays for analyzing transcription factors.

    Science.gov (United States)

    Li, Xianqiang; Jiang, Xin; Yaoi, Takuro

    2006-06-01

    Transcription factors are a group of proteins that modulate the expression of genes involved in many biological processes, such as cell growth and differentiation. Alterations in transcription factor function are associated with many human diseases, and therefore these proteins are attractive potential drug targets. A key issue in the development of such therapeutics is the generation of effective tools that can be used for high throughput discovery of the critical transcription factors involved in human diseases, and the measurement of their activities in a variety of disease or compound-treated samples. Here, a number of innovative arrays and 96-well format assays for profiling and measuring the activities of transcription factors will be discussed. PMID:16834538

  5. Advancement in biochemical assays in andrology

    Institute of Scientific and Technical Information of China (English)

    Wolf-BernhardSchill; RaftHenkel

    1999-01-01

    Determination of maikers of sperm function, accessory sex gland secretion and silent male genital tract inflammation is of considerable diagnostic value in the evaluation of male infertility. The introduction of biochemical tests into the analysis of male factor has the advantage that standardized assays with a coefficient of variafion characteristic of clinical chemistry are performed, in contrast to biological test systems with a large variability .Biochemical parameters may be used in clinical practice to evaluate the sperm fertitizing capacity (acrosin, aniline blue,ROS), to characterize male accessory sex gland secretinns (fructose, a-glucosidase, PSA), and to identify men with silent genital tract inflammation (elastase, C'3 complement component, coeruloplasmin, IgA, IgG, ROS). (As/an J Androl 1999 Jun; 1: 45-51)

  6. Improved internal control for molecular diagnosis assays.

    Science.gov (United States)

    Vinayagamoorthy, T; Maryanski, Danielle; Vinayagamoorthy, Dilanthi; Hay, Katie S L; Yo, Jacob; Carter, Mark; Wiegel, Joseph

    2015-01-01

    The two principal determining steps in molecular diagnosis are the amplification and the identification steps. Accuracy of DNA amplification is primarily determined by the annealing sequence of the PCR primer to the analyte DNA. Accuracy for identification is determined either by the annealing region of a labelled probe for the real time PCR analysis, or the annealing of a sequencing primer for DNA sequencing analysis, that binds to the respective analyte (amplicon). Presently, housekeeping genes (Beta globin, GAPDH) are used in molecular diagnosis to verify that the PCR conditions are optimum, and are thus known as amplification controls [1-4]. Although these genes have been useful as amplification controls, they lack the true definition of an internal control because the primers and annealing conditions are not identical to the analyte being assayed. This may result in a false negative report [5]. The IC-Code platform technology described here provides a true internal control where the internal control and analyte share identical PCR primers annealing sequences for the amplification step and identical sequencing primer annealing sequence for the identification step. •The analyte and internal control have the same PCR and sequencing annealing sequences.•This method assures for little or no false negatives and false positives due to the method's design of using identical annealing conditions for the internal control and analyte, and by using DNA sequencing analysis for the identification step of the analyte, respectively.•This method also allows for a set lower limit of detection to be used by varying the amount of internal control used in the assay.

  7. Performance of MycAssay Aspergillus DNA real-time PCR assay compared with the galactomannan detection assay for the diagnosis of invasive aspergillosis from serum samples.

    Science.gov (United States)

    Danylo, Alexis; Courtemanche, Chantal; Pelletier, René; Boudreault, Alexandre A

    2014-08-01

    Invasive aspergillosis (IA) is a major problem in the immunocompromised population, and its diagnosis is difficult due to the low sensitivity of available tests. Detection of Aspergillus nucleic acid by polymerase chain reaction (PCR) in serum samples is a promising diagnostic tool; however, use of multiple "in-house" methods precludes standardization. The first commercial PCR assay, MycAssay Aspergillus (Myconostica, Ltd), became available recently, and its performance in the diagnosis of IA was evaluated and compared with the galactomannan (GM) assay. Serum samples obtained from patients with hematological cancer were tested retrospectively with MycAssay Aspergillus PCR. Per-episode and per-test analyses were undertaken with 146 sera from 35 hematological patients. Sixteen patients had proven or probable IA and 19 had possible or no IA. In per-episode analysis, MycAssay Aspergillus had a sensitivity of 43.8% (95% confidence interval [CI], 19.8%-70.1%) and a specificity of 63.2% (95% CI, 38.4%-83.7%) for IA diagnosis. In per-test analyses, MycAssay Aspergillus had a lower specificity than the GM assay (83.3% vs. 93.1%, P = 0.04). The addition of PCR to routine clinical practice would have permitted the diagnosis of one additional probable IA in our cohort. Use of PCR instead of GM assay would have delayed the diagnosis in two cases. Aspergillus DNA detection by PCR with serum specimens using MycAssay showed a lower specificity than the GM assay and was associated with a low sensitivity for IA diagnosis. More studies are needed to determine the exact role of MycAssay in IA diagnosis in patients with hematological malignancy.

  8. Detection of Chlamydia trachomatis by Nucleic Acid Amplification Testing: Our Evaluation Suggests that CDC-Recommended Approaches for Confirmatory Testing Are Ill-Advised

    OpenAIRE

    Schachter, Julius; Chow, Joan M.; Howard, Holly; Bolan, Gail; Moncada, Jeanne

    2006-01-01

    We evaluated three CDC-suggested approaches for confirming positive nucleic acid amplification tests (NAATs) for Chlamydia trachomatis: (i) repeat the original test on the original specimen, (ii) retest the original specimen with a different test, and (iii) perform a different test on a duplicate specimen. For approach 1, specimens (genital swabs or first-catch urine [FCU]) initially positive by the Abbott LCx Probe System Chlamydia trachomatis Assay (LCx; Abbott Laboratories), the APTIMA Com...

  9. Principles of validation of diagnostic assays for infectious diseases

    International Nuclear Information System (INIS)

    Assay validation requires a series of inter-related processes. Assay validation is an experimental process: reagents and protocols are optimized by experimentation to detect the analyte with accuracy and precision. Assay validation is a relative process: its diagnostic sensitivity and diagnostic specificity are calculated relative to test results obtained from reference animal populations of known infection/exposure status. Assay validation is a conditional process: classification of animals in the target population as infected or uninfected is conditional upon how well the reference animal population used to validate the assay represents the target population; accurate predictions of the infection status of animals from test results (PV+ and PV-) are conditional upon the estimated prevalence of disease/infection in the target population. Assay validation is an incremental process: confidence in the validity of an assay increases over time when use confirms that it is robust as demonstrated by accurate and precise results; the assay may also achieve increasing levels of validity as it is upgraded and extended by adding reference populations of known infection status. Assay validation is a continuous process: the assay remains valid only insofar as it continues to provide accurate and precise results as proven through statistical verification. Therefore, the work required for validation of diagnostic assays for infectious diseases does not end with a time-limited series of experiments based on a few reference samples rather, to assure valid test results from an assay requires constant vigilance and maintenance of the assay, along with reassessment of its performance characteristics for each unique population of animals to which it is applied. (author)

  10. Heated oligonucleotide ligation assay (HOLA): an affordable single nucleotide polymorphism assay.

    Science.gov (United States)

    Black, W C; Gorrochotegui-Escalante, N; Duteau, N M

    2006-03-01

    Most single nucleotide polymorphism (SNP) detection requires expensive equipment and reagents. The oligonucleotide ligation assay (OLA) is an inexpensive SNP assay that detects ligation between a biotinylated "allele-specific detector" and a 3' fluorescein-labeled "reporter" oligonucleotide. No ligation occurs unless the 3' detector nucleotide is complementary to the SNP nucleotide. The original OLA used chemical denaturation and neutralization. Heated OLA (HOLA) instead uses a thermal stable ligase and cycles of denaturing and hybridization for ligation and SNP detection. The cost per genotype is approximately US$1.25 with two-allele SNPs or approximately US$1.75 with three-allele SNPs. We illustrate the development of HOLA for SNP detection in the Early Trypsin and Abundant Trypsin loci in the mosquito Aedes aegypti (L.) and at the a-glycerophosphate dehydrogenase locus in the mosquito Anopheles gambiae s.s.

  11. Mouse lung adhesion assay for Bordetella pertussis

    Energy Technology Data Exchange (ETDEWEB)

    Burns, K.A.; Freer, J.H. (Department of Microbiology, Alexander Stone Building, Bearsden, Glasgow, Scotland)

    1982-03-01

    The ability of Bordetella pertussis to adhere to cell surfaces has been demonstrated by adhesion to tissue culture cells and adhesion to chicken, hamster or rabbit trachea in organ culture. In this report a mouse lung assay for adhesion is described and the results obtained using two virulent strains of B. pertussis and their avirulent counterparts. These were a C modulation of one of the original virulent strains and a phase IV variant of the other virulent strain. Organisms were radiolabelled by adding 1 ..mu..Ci (37 K Bq) of (/sup 14/C)glutamic acid per 10 ml of culture medium before inoculation and incubation for 5 days. The lungs were washed by perfusion in situ with at least two volumes (1 ml) of sterile 1% (w/v) casamino acids. The percentage of the inoculated organisms retained in the lungs was determined, after removal of the lungs, by one of the following two methods: viable count or radioactive count. Results for both methods were expressed as the percentage of the inoculum retained in the lungs plus or minus one standard deviation.

  12. Establishment of indirect immunofluorescence assay for rotavirus.

    Science.gov (United States)

    Tao, J; Zhang, J; Liu, X; Jin, H; Jiang, C; Yin, Y

    2016-03-01

    Rotavirus infection is the most frequent cause of infantile gastroenteritis worldwide and a significant cause of death in infants and young children, following severe diarrhea and dehydration. Rotavirus vaccines are considered the most effective way to prevent rotavirus infections. In the process of developing rotavirus vaccines, it is crucial to establish a reliable and standardized method to determine vaccine titer. In this study, we developed an indirect immunofluorescence assay (IFA) to determine the infectious titer of Lanzhou lamb rotavirus (LLR) vaccine grown in MA104 cells. The activating concentration of trypsin was 1 µg/ml for healthy monolayers of MA104 cells at 100% confluence. After incubation for 18 hr, a rabbit anti-SA11 polyclonal antibody, diluted at 1:800 in PBS, was added to all wells, followed by an Alexa-488-conjugated secondary antibody diluted at 1:500 in PBS. Cells were examined with a fluorescence microscope. Our results show that IFA was more reproducible, more sensitive, simpler, and more rapid than the log 50% cell culture infectious dose-ELISA (lgCCID50-ELISA) in measuring the rotavirus vaccines. IFA provided a reliable basis for the qualitative and quantitative analysis of rotavirus, and the certification of rotavirus vaccine production.

  13. Immunoradiometric assay for ferritin in human serum

    International Nuclear Information System (INIS)

    A sensitiv specific and precise immunoradiometric assay for ferritin has been developed. Ferritin was measured in the serum of 160 hospital controls, 101 females (118 plus/minus 9 μg/l) and 59 males (189 plus/minus 16 μg/l). This difference was statistically significant. In 28 patients with untreated iron deficiency anemia, serum ferritin concentration (6.1plus/minus 0.7 μg/l) was significantly lower than in the controls, but it was within the normal range in 14 cases of polycythaemia vera treated by repeated phlebotomy. In 4 patients with primary haemachromatosis (2884 plus/minus 56 μg/l), 25 with secondary iron overload states (5702 plus/minus 1235 μg/l) and 8 with haemolytic anaemia (1612 plus/minus 605 μg/l), serum ferritin levels were markedly elevated. In 14 cases of transfusional siderosis there was a highly significant correlation between serum ferritin concentration and units of blood transfused. A circadian rhythmin serum ferritin concentration was observed in 7 healthy subjects. (author)

  14. Fluorescence Polarization Assays in Small Molecule Screening

    Science.gov (United States)

    Lea, Wendy A.; Simeonov, Anton

    2011-01-01

    Importance of the field Fluorescence polarization (FP) is a homogeneous method that allows rapid and quantitative analysis of diverse molecular interactions and enzyme activities. This technique has been widely utilized in clinical and biomedical settings, including the diagnosis of certain diseases and monitoring therapeutic drug levels in body fluids. Recent developments in the field has been symbolized by the facile adoption of FP in high-throughput screening (HTS) and small molecule drug discovery of an increasing range of target classes. Areas covered in this review The article provides a brief overview on the theoretical foundation of FP, followed by updates on recent advancements in its application for various drug target classes, including G-protein coupled receptors (GPCRs), enzymes and protein-protein interactions (PPIs). The strengths and weaknesses of this method, practical considerations in assay design, novel applications, and future directions are also discussed. What the reader will gain The reader will be informed of the most recent advancements and future directions of FP application to small molecule screening. Take home message In addition to its continued utilization in high-throughput screening, FP has expanded into new disease and target areas and has been marked by increased use of labeled small molecule ligands for receptor binding studies. PMID:22328899

  15. Granuloma pouch assay for mutagenicity testing.

    Science.gov (United States)

    Maier, P

    1980-11-01

    The Granuloma Pouch Assay (GPA) is an animal model in which mutagenic and carcinogenic effects of a testcompound can be detected in rapidly dividing fibroblasts of a granulation tissue in adult male rats. Growth of this tissue was initiated with a small amount of croton oil at the inside wall of a subcutaneous air pouch on the back of the animals. The test compound can be injected either into the pouch (local) or administered by systemic routes. Alkali labile DNA-lesions, chromosome aberrations, sister chromatid exchanges, point mutations and tumor development in situ were determined. The comparison of mutation frequencies after local and systemic administration of testcompounds, provide an estimation of the pharmacokinetic characteristics and the mutagenic potency of the chemical. The local application route allows the detection of locally active mutagens and of compounds which require activation by P-448 dependent mono-oxygenases. Liver mediated proximate metabolites are detectable when they are transformed into ultimate carcinogens in extrahepatic cells whereas chemicals with a strong organ specific activity are not. PMID:7235991

  16. Assaying Visual Memory in the Desert Locust

    Directory of Open Access Journals (Sweden)

    Senne Dillen

    2015-04-01

    Full Text Available The involvement of associative learning cues has been demonstrated in several stages of feeding and food selection. Short neuropeptide F (sNPF, an insect neuropeptide whose effects on feeding behavior have previously been well established, may be one of the factors bridging feeding and learning behavior. Recently, it was shown in Drosophila melanogaster that the targeted reduction of Drome-sNPF transcript levels significantly reduced sugar-rewarded olfactory memory. While Drosophila mainly relies on olfactory perception in its food searching behavior, locust foraging behavior is likely to be more visually orientated. Furthermore, a feeding-dependent regulation of Schgr-sNPF transcript levels has previously been observed in the optic lobes of the locust brain, suggesting a possible involvement in visual perception of food and visual associative memory in this insect species. In this study, we describe the development of a robust and reproducible assay allowing visual associative memory to be studied in the desert locust, Schistocerca gregaria. Furthermore, we performed an exploratory series of experiments, studying the role of Schgr-sNPF in this complex process.

  17. Assaying Visual Memory in the Desert Locust.

    Science.gov (United States)

    Dillen, Senne; Chen, Ziwei; Broeck, Jozef Vanden

    2015-01-01

    The involvement of associative learning cues has been demonstrated in several stages of feeding and food selection. Short neuropeptide F (sNPF), an insect neuropeptide whose effects on feeding behavior have previously been well established, may be one of the factors bridging feeding and learning behavior. Recently, it was shown in Drosophila melanogaster that the targeted reduction of Drome-sNPF transcript levels significantly reduced sugar-rewarded olfactory memory. While Drosophila mainly relies on olfactory perception in its food searching behavior, locust foraging behavior is likely to be more visually orientated. Furthermore, a feeding-dependent regulation of Schgr-sNPF transcript levels has previously been observed in the optic lobes of the locust brain, suggesting a possible involvement in visual perception of food and visual associative memory in this insect species. In this study, we describe the development of a robust and reproducible assay allowing visual associative memory to be studied in the desert locust, Schistocerca gregaria. Furthermore, we performed an exploratory series of experiments, studying the role of Schgr-sNPF in this complex process. PMID:26463192

  18. Background Assay and Rejection in DRIFT

    CERN Document Server

    Brack, Jeff; Dorofeev, Alexei; Ezeribe, Anthony; Gauvreau, Jean-Luc; Gold, Michael; Harton, John; Lafler, Randy; Lauer, Robert; Lee, Eric R; Loomba, Dinesh; Matthews, John; Miller, Eric H; Monte, Alissa; Murphy, Alex; Paling, Sean; Phan, Nguyen; Sadler, Steve; Scarff, Andrew; Snowden-Ifft, Daniel; Spooner, Neil; Telfer, Sam; Walker, Daniel; Williams, Matt; Yuriev, Leonid

    2014-01-01

    The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 \\mu m wire central cathode with one constructed from 0.9 \\mu m aluminized mylar, which is almost totally transparent to alpha particles. Detailed modeling of the nature and origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of alpha decay backgrounds from the central cathode. This led to further improvements in the thin-film cathode resulting in over 2 orders of magnitude reduction in backgrounds compared to the wire cathode. Finally, the addition of O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative charge carriers, providing a method to determine the absolute position of nuclear recoils and reject all known remaining backgrounds while retaining a high efficiency for nuclear recoil...

  19. Interpreting clinical assays for histone deacetylase inhibitors

    International Nuclear Information System (INIS)

    As opposed to genetics, dealing with gene expressions by direct DNA sequence modifications, the term epigenetics applies to all the external influences that target the chromatin structure of cells with impact on gene expression unrelated to the sequence coding of DNA itself. In normal cells, epigenetics modulates gene expression through all development steps. When “imprinted” early by the environment, epigenetic changes influence the organism at an early stage and can be transmitted to the progeny. Together with DNA sequence alterations, DNA aberrant cytosine methylation and microRNA deregulation, epigenetic modifications participate in the malignant transformation of cells. Their reversible nature has led to the emergence of the promising field of epigenetic therapy. The efforts made to inhibit in particular the epigenetic enzyme family called histone deacetylases (HDACs) are described. HDAC inhibitors (HDACi) have been proposed as a viable clinical therapeutic approach for the treatment of leukemia and solid tumors, but also to a lesser degree for noncancerous diseases. Three epigenetic drugs are already arriving at the patient’s bedside, and more than 100 clinical assays for HDACi are registered on the National Cancer Institute website. They explore the eventual additive benefits of combined therapies. In the context of the pleiotropic effects of HDAC isoforms, more specific HDACi and more informative screening tests are being developed for the benefit of the patients

  20. Optimization of cell motility evaluation in scratch assay

    Directory of Open Access Journals (Sweden)

    Gotsulyak N. Ya.

    2014-05-01

    Full Text Available A scratch test is one of the most popular methods of classical cell migration assay in a monolayer culture. At the same time, the scratch assay has some disadvantages that can be easily corrected. Aim. Optimization the existent scratch assay on the base of detection of scratch wound surface area and the length of the field of observation which is more objective and less time consuming. Methods. Scratch assay. Results. The modification of scratch assay enables to perform measurement more accurately and rapidly. This approach is more simple and eliminates the main disadvantages of the classical method. Conclusions. The procedure of scratch wound width measurement calculated on the base of detection of cell free area and the length of the field of observation is more effective than the classical wound healing assay. It will be useful for the estimation of cell migration dynamics in monolayer culture for a wide range of live cell based experiments.

  1. Ecotoxicological Assessment of Aquatic Genotoxicity Using the Comet Assay

    Directory of Open Access Journals (Sweden)

    KHUSNUL YAQIN

    2006-09-01

    Full Text Available Comet assay is a novel biological analysis, which is a sensitive, flexible, simple, rapid, and inexpensive method to assess aquatic genotoxicant. Since Singh and co-workers developed the method in 1988, its use has increased exponentially in various fields. This review discourses on the application of this assay in aquatic ecosystems. Various types of cells from various aquatic organisms have been tested by various genotoxicant both direct- and indirect-acting using the comet assay. The applications of this assay suggest that it is a useful assay to assess aquatic genotoxicants. However, there are some factors, which should be taken into account when using this assay as aquatic ecotoxicological assessment device such as inter-animal and cell variability.

  2. A comprehensive company database analysis of biological assay variability.

    Science.gov (United States)

    Kramer, Christian; Dahl, Göran; Tyrchan, Christian; Ulander, Johan

    2016-08-01

    Analysis of data from various compounds measured in diverse biological assays is a central part of drug discovery research projects. However, no systematic overview of the variability in biological assays has been published and judgments on assay quality and robustness of data are often based on personal belief and experience within the drug discovery community. To address this we performed a reproducibility analysis of all biological assays at AstraZeneca between 2005 and 2014. We found an average experimental uncertainty of less than a twofold difference and no technologies or assay types had higher variability than others. This work suggests that robust data can be obtained from the most commonly applied biological assays.

  3. Multiplex cytological profiling assay to measure diverse cellular states.

    Directory of Open Access Journals (Sweden)

    Sigrun M Gustafsdottir

    Full Text Available Computational methods for image-based profiling are under active development, but their success hinges on assays that can capture a wide range of phenotypes. We have developed a multiplex cytological profiling assay that "paints the cell" with as many fluorescent markers as possible without compromising our ability to extract rich, quantitative profiles in high throughput. The assay detects seven major cellular components. In a pilot screen of bioactive compounds, the assay detected a range of cellular phenotypes and it clustered compounds with similar annotated protein targets or chemical structure based on cytological profiles. The results demonstrate that the assay captures subtle patterns in the combination of morphological labels, thereby detecting the effects of chemical compounds even though their targets are not stained directly. This image-based assay provides an unbiased approach to characterize compound- and disease-associated cell states to support future probe discovery.

  4. Microplate phosphocellulose binding assay for aminoglycoside-modifying enzymes.

    OpenAIRE

    Cooksey, R C; Metchock, B G; Thornsberry, C

    1986-01-01

    We modified the phosphocellulose binding assay for aminoglycoside-modifying enzymes (AMEs) by use of microdilution plates and a multichannel micropipette. Batteries of aminoglycoside substrates for screening organisms for the presence of AMEs as well as for subclassifying enzymes were prepared and stored in microdilution plates. When tested in parallel with the conventional tube reaction assay, the microplate assay yielded comparable radioactive counts and therefore equally correct identifica...

  5. Epithelial cells as alternative human biomatrices for comet assay

    OpenAIRE

    Rojas, Emilio; Lorenzo, Yolanda; Haug, Kristiane; Nicolaissen, Bjørn; Valverde, Mahara

    2014-01-01

    The comet assay is a valuable experimental tool aimed at mapping DNA damage in human cells in vivo for environmental and occupational monitoring, as well as for therapeutic purposes, such as storage prior to transplant, during tissue engineering, and in experimental ex vivo assays. Furthermore, due to its great versatility, the comet assay allows to explore the use of alternative cell types to assess DNA damage, such as epithelial cells. Epithelial cells, as specialized components of many org...

  6. Ecotoxicological Assessment of Aquatic Genotoxicity Using the Comet Assay

    OpenAIRE

    KHUSNUL YAQIN

    2006-01-01

    Comet assay is a novel biological analysis, which is a sensitive, flexible, simple, rapid, and inexpensive method to assess aquatic genotoxicant. Since Singh and co-workers developed the method in 1988, its use has increased exponentially in various fields. This review discourses on the application of this assay in aquatic ecosystems. Various types of cells from various aquatic organisms have been tested by various genotoxicant both direct- and indirect-acting using the comet assay. The appli...

  7. Rapid and sensitive assay for the phytotoxin rhizobitoxine.

    OpenAIRE

    Ruan, X.; Peters, N K

    1991-01-01

    Rhizobitoxine is a phytotoxin synthesized by some strains of the legume symbiont genus Bradyrhizobium and the plant pathogen Pseudomonas andropogonis. We demonstrate here a new enzymatic assay which is 100-fold more sensitive than previous assays and can detect as little as 1.0 pmol of rhizobitoxine. The assay is based on the inhibition of Salmonella typhimurium beta-cystathionase by rhizobitoxine. Interestingly, beta-cystathionase from Bradyrhizobium japonicum is insensitive to rhizobitoxine...

  8. Click Chemistry-Mediated Nanosensors for Biochemical Assays

    OpenAIRE

    Chen, Yiping; Xianyu, Yunlei; Wu, Jing; Yin, Binfeng; Jiang, Xingyu

    2016-01-01

    Click chemistry combined with functional nanoparticles have drawn increasing attention in biochemical assays because they are promising in developing biosensors with effective signal transformation/amplification and straightforward signal readout for clinical diagnostic assays. In this review, we focus on the latest advances of biochemical assays based on Cu (I)-catalyzed 1, 3-dipolar cycloaddition of azides and alkynes (CuAAC)-mediated nanosensors, as well as the functionalization of nanopro...

  9. Development of fluorometric reactive oxygen species assay for photosafety evaluation.

    Science.gov (United States)

    Seto, Yoshiki; Ohtake, Hiroto; Kato, Masashi; Onoue, Satomi

    2016-08-01

    The present investigation involved an attempt to develop a new reactive oxygen species (ROS) assay system for the photosafety assessment of chemicals using 1,3-diphenylisobenzofuran (DPBF), a fluorescent probe for monitoring ROS generation. The assay conditions of the fluorometric ROS (fROS) assay were optimized focusing on the solvent system, concentration of DPBF, fluorescent determination, screening run time and reproducibility. The photoreactivity of 21 phototoxic and 11 non-phototoxic compounds was assessed by fROS assay, and the obtained ROS data were compared with the results from a micellar ROS (mROS) assay and in vitro/in vivo phototoxicity information to confirm the predictive capacity of the fROS assay. In the optimized fROS assay, intra-day and inter-day precision levels (coefficient of variation) were found to be below 5%, and the Z'-factor for DPBF fluorescence quenching showed a large separation between positive and negative controls. Of all tested compounds, 3 false positive and 7 false negative predictions were observed in the fROS assay, and the negative predictivity for the fROS assay was found to be lower than that for the mROS assay. Although the fROS assay has some limitations, the procedures for it were highly simplified with a marked reduction in screening run time and one analytical sample for monitoring ROS generation from compounds. The fROS assay has the potential to become a new tool for photosafety assessment at an early stage of product development. PMID:27058001

  10. A homogeneous nucleic acid hybridization assay based on strand displacement.

    OpenAIRE

    Vary, C P

    1987-01-01

    A homogeneous nucleic acid hybridization assay which is conducted in solution and requires no separation steps is described. The assay is based on the concept of strand displacement. In the strand displacement assay, an RNA "signal strand" is hybridized within a larger DNA strand termed the "probe strand", which is, in turn, complementary to the target nucleic acid of interest. Hybridization of the target nucleic acid with the probe strand ultimately results in displacement of the RNA signal ...

  11. DNA repair in plants studied by comet assay

    OpenAIRE

    Karel J Angelis; Jaroslav Kozák

    2015-01-01

    Comet assay in plants. From the first description of the comet assay with isolated nuclei rather than whole cells it became evident that assay is well suited to be applied in plants (Koppen & Verschaeve, 1996). Disintegration of tissue by quick chopping with a razor blade, direct collection of released nuclei by patting and pipetting enables to process samples in time shorter than 2 minutes, the time prerequisite to study quick repair (Kozak et al, 2009). Plants are due to their sessil...

  12. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  13. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Mano K.; Snyderman, Neal J.; Rowland, Mark S.

    2015-12-01

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  14. Establishment of an Enzyme Linked Immunosorbent Assay for Neonatal Thyrotropin

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A sensitive and specific ELISA for neonatal thyrotropin(Neonatal TSH) is established with using twoanti-TSH monoclonal antibody. One of them is coated on the microtiter plate, the other is conjugate ofbiotin. The label is horseradish peroxidase(HRP) conjugate of streptavidin. TMB-H2O2 solution is used asthe substrate of HRP.The sensitivity of the assay is 0.5 mIU/L, the intra-assay CVs and the intre-assay

  15. Variance in multiplex suspension array assays: microsphere size variation impact

    OpenAIRE

    Cheng R Holland; Xing Li; Hanley Brian P

    2007-01-01

    Abstract Background Luminex suspension microarray assays are in widespread use. There are issues of variability of assay readings using this technology. Methods and results Size variation is demonstrated by transmission electron microscopy. Size variations of microspheres are shown to occur in stepwise increments. A strong correspondence between microsphere size distribution and distribution of fluorescent events from assays is shown. An estimate is made of contribution of microsphere size va...

  16. Robust versatile tyrosine kinase assay for HTS in drug discovery

    Science.gov (United States)

    Deshpande, Sudhir S.; Mineyev, I.; Owicki, John C.

    1999-04-01

    A fluorescence polarization assay was developed as an alternative to the radiolabeled SPA assays currently used to monitor the activity of tyrosine kinases in drug discovery. The assay can be used with enzymes having substrate specificity similar to that of the insulin receptor, the EGF receptor and the Src kinase receptor enzymes. The assay is easy to configure in 96, 384 and 1536-well microplates in assay volumes ranging from (mu) L with minimal efforts. The reconstituted reagents are stable for up to 24 hr at ambient temperatures, thereby minimizing the need for replenishing the stock solutions during the course of a high-throughput screen. Because of the stability and equilibrium kinetics, the assay allows the user the luxury of scheduling the reading of plates any time up to 24 hr after the completion of the assay without substantial deterioration in the assay signal. The antibody and the tracer solutions can also be premixed and added as a preformed complex in a single step. The performance of the assay with the insulin receptor kinase is described. In addition, given the diversity of the substrates used in measuring the activity of different tyrosine kinases, LJL's on-going efforts to provide different antibodies of wide ranging specificity and sensitivity are described.

  17. Computer-determined assay time based on preset precision

    Energy Technology Data Exchange (ETDEWEB)

    Foster, L.A.; Hagan, R.; Martin, E.R.; Wachter, J.R.; Bonner, C.A.; Malcom, J.E. [Los Alamos National Lab., NM (United States). Nuclear Materials Measurement and Accountability

    1994-08-01

    Most current assay systems for special nuclear materials (SNM) operate on the principle of a fixed assay time which provides acceptable measurement precision without sacrificing the required throughput of the instrument. Waste items to be assayed for SNM content can contain a wide range of nuclear material. Counting all items for the same preset assay time results in a wide range of measurement precision and wastes time at the upper end of the calibration range. A short time sample taken at the beginning of the assay could optimize the analysis time on the basis of the required measurement precision. To illustrate the technique of automatically determining the assay time, measurements were made with a segmented gamma scanner at the Plutonium Facility of Los Alamos National Laboratory with the assay time for each segment determined by counting statistics in that segment. Segments with very little SNM were quickly determined to be below the lower limit of the measurement range and the measurement was stopped. Segments with significant SNM were optimally assays to the preset precision. With this method the total assay time for each item is determined by the desired preset precision. This report describes the precision-based algorithm and presents the results of measurements made to test its validity.

  18. Detection of radiation-induced apoptosis using the comet assay

    International Nuclear Information System (INIS)

    The electrophoresis pattern of apoptotic cells detected by the comet assay has a characteristic small head and spread tail. This image has been referred to as an apoptotic comet, but it has not been previously proven to be apoptotic cells by any direct method. In order to identify this image obtained by the comet assay as corresponding to an apoptotic cell, the frequency of appearance of apoptosis was examined using CHO-K1 and L5178Y cells which were exposed to gamma irradiation. As a method for detecting apoptosis, the terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL) assay was used. When the frequency of appearance of apoptotic cells following gamma irradiation was observed over a period of time, there was a significant increase in appearance of apoptosis when using the TUNEL assay. However, there was only a slight increase when using the comet assay. In order to verify the low frequency of appearance of apoptosis when using the comet assay, we attempted to use the TUNEL assay to satin the apoptotic comets detected in the comet assay. The apoptotic comets were TUNEL positive and the normal comets were TUNEL negative. This indicates that the apoptotic comets were formed from DNA fragments with 3'-hydroxy ends that are generated as cells undergo apoptosis. Therefore, it was understood that the characteristic pattern of apoptotic comets detected by the comet assay corresponds to cells undergoing apoptosis. (author)

  19. Development and Evaluation of a Novel Taqman Real-Time PCR Assay for Rapid Detection of Mycoplasma bovis: Comparison of Assay Performance with a Conventional PCR Assay and Another Taqman Real-Time PCR Assay

    OpenAIRE

    Hemant Naikare; Daniela Bruno; Debabrata Mahapatra; Alesia Reinisch; Russell Raleigh; Robert Sprowls

    2015-01-01

    The objective of this study was to develop and validate a Taqman real-time PCR assay for the detection of Mycoplasma bovis (M. bovis). Unique primers targeting the highly conserved house-keeping gene (uvrC) were designed and the probe sequence was derived from a previously published microarray study. There was 100% agreement in the outcome between our assay and the other two published assays for M. bovis detection. The analytical limit of detection of our assay is 83 copies of the uvrC gene. ...

  20. Cell Migration and Invasion Assays as Tools for Drug Discovery

    Directory of Open Access Journals (Sweden)

    Keren I. Hulkower

    2011-03-01

    Full Text Available Cell migration and invasion are processes that offer rich targets for intervention in key physiologic and pathologic phenomena such as wound healing and cancer metastasis. With the advent of high-throughput and high content imaging systems, there has been a movement towards the use of physiologically relevant cell-based assays earlier in the testing paradigm. This allows more effective identification of lead compounds and recognition of undesirable effects sooner in the drug discovery screening process. This article will review the effective use of several principle formats for studying cell motility: scratch assays, transmembrane assays, microfluidic devices and cell exclusion zone assays.

  1. Characterization of decommissioned reactor internals: Direct-assay method assessment

    International Nuclear Information System (INIS)

    This study describes the direct-assay technique for measuring activation levels of irradiated reactor component hardware. It also compares the direct-assay technique with calculational analysis methods that predict activation levels. Direct assay is performed in four steps: (a) planning and component selection, (b) onsite measurements, (c) radiochemical analysis, and (d) data analysis and classification. Uncertainties are estimated for each step of this process, and an overall uncertainty in the classification accuracy is calculated as about ±35%. Numerous research ideas are identified to help reduce the uncertainty level; many of these ideas would improve activation determinations performed by either direct assay or by calculational analysis methods

  2. Characterization of decommissioned reactor internals: Direct-assay method assessment

    Energy Technology Data Exchange (ETDEWEB)

    Cline, J.E.

    1993-03-01

    This study describes the direct-assay technique for measuring activation levels of irradiated reactor component hardware. It also compares the direct-assay technique with calculational analysis methods that predict activation levels. Direct assay is performed in four steps: (a) planning and component selection, (b) onsite measurements, (c) radiochemical analysis, and (d) data analysis and classification. Uncertainties are estimated for each step of this process, and an overall uncertainty in the classification accuracy is calculated as about {plus_minus}35%. Numerous research ideas are identified to help reduce the uncertainty level; many of these ideas would improve activation determinations performed by either direct assay or by calculational analysis methods.

  3. An assay for measurement of protein adsorption to glass vials.

    Science.gov (United States)

    Varmette, Elizabeth; Strony, Brianne; Haines, Daniel; Redkar, Rajendra

    2010-01-01

    Protein adsorption to primary packaging is one of the problems faced by biopharmaceutical drug companies. An assay was developed to quantify loss of proteins to glass vial surfaces. The assay involves the labeling of protein with a fluorescent dye, incubation of the labeled protein with the vial surface, elution of the adsorbed protein using a stripping buffer, and determination of fluorescence of the adsorbed protein using a fluorometer. The assay is simple to set up, accurate, sensitive, and flexible. The assay can be modified for indirect measurement of protein adsorption and offers an attractive alternative for researchers to quantify protein adsorption to glass vials and syringes. PMID:21502031

  4. Inferring Protein Associations Using Protein Pulldown Assays

    Energy Technology Data Exchange (ETDEWEB)

    Sharp, Julia L.; Anderson, Kevin K.; Daly, Don S.; Auberry, Deanna L.; Borkowski, John J.; Cannon, William R.

    2007-02-01

    Background: One method to infer protein-protein associations is through a “bait-prey pulldown” assay using a protein affinity agent and an LC-MS (liquid chromatography-mass spectrometry)-based protein identification method. False positive and negative protein identifications are not uncommon, however, leading to incorrect inferences. Methods: A pulldown experiment generates a protein association matrix wherein each column represents a sample from one bait protein, each row represents one prey protein and each cell contains a presence/absence association indicator. Our method evaluates the presence/absence pattern across a prey protein (row) with a Likelihood Ratio Test (LRT), computing its p-value with simulated LRT test statistic distributions after a check with simulated binomial random variates disqualified the large sample 2 test. A pulldown experiment often involves hundreds of tests so we apply the false discovery rate method to control the false positive rate. Based on the p-value, each prey protein is assigned a category (specific association, non-specific association, or not associated) and appraised with respect to the pulldown experiment’s goal and design. The method is illustrated using a pulldown experiment investigating the protein complexes of Shewanella oneidensis MR-1. Results: The Monte Carlo simulated LRT p-values objectively reveal specific and ubiquitous prey, as well as potential systematic errors. The example analysis shows the results to be biologically sensible and more realistic than the ad hoc screening methods previously utilized. Conclusions: The method presented appears to be informative for screening for protein-protein associations.

  5. Rapid quantitative assay for chloramphenicol acetyltransferase

    International Nuclear Information System (INIS)

    Measuring the expression of exogenous genetic material in mammalian cells is commonly done by fusing the DNA of interest to a gene encoding an easily-detected enzyme. Chloramphenicol acetyltransferase(CAT) is a convenient marker because it is not normally found in eukaryotes. CAT activity has usually been detected using a thin-layer chromatographic separation followed by autoradiography. An organic solvent extraction-based method for CAT detection has also been described, as well as a procedure utilizing HPLC analysis. Building on the extraction technique, they developed a rapid sensitive kinetic method for measuring CAT activity in cell homogenates. The method exploits the differential organic solubility of the substrate ([3H] or [14C]acetyl CoA) and the product (labeled acetylchloramphenicol). The assay is a simple one-vial, two-phase procedure and requires no tedious manipulations after the initial setup. Briefly, a 0.25 ml reaction with 100mM Tris-HCL, 1mM chloramphenicol, 0.1mM [14C]acetyl CoA and variable amounts of cell homogenate is pipetted into a miniscintillation vial, overlaid with 5 ml of a water-immiscible fluor, and incubated at 370C. At suitable intervals the vial is counted and the CAT level is quantitatively determined as the rate of increase in counts/min of the labeled product as it diffuses into the fluor phase, compared to a standard curve. When used to measure CAT in transfected Balb 3T3 cells the method correlated well with the other techniques

  6. Assessment and reduction of comet assay variation in relation to DNA damage: studies from the European Comet Assay Validation Group

    DEFF Research Database (Denmark)

    Møller, Peter; Möller, Lennart; Godschalk, Roger W L;

    2010-01-01

    The alkaline single cell gel electrophoresis (comet) assay has become a widely used method for the detection of DNA damage and repair in cells and tissues. Still, it has been difficult to compare results from different investigators because of differences in assay conditions and because the data...... are reported in different units. The European Comet Assay Validation Group (ECVAG) was established for the purpose of validation of the comet assay with respect to measures of DNA damage formation and its repair. The results from this inter-laboratory validation trail showed a large variation in...... substantial reliability for the measurement of DNA damage by the comet assay but there is still a need for further validation to reduce both assay and inter-laboratory variation....

  7. Fully Bayesian Analysis of High-throughput Targeted Metabolomics Assays

    Science.gov (United States)

    High-throughput metabolomic assays that allow simultaneous targeted screening of hundreds of metabolites have recently become available in kit form. Such assays provide a window into understanding changes to biochemical pathways due to chemical exposure or disease, and are usefu...

  8. A novel immunoradiometric assay for human liver ferritin.

    OpenAIRE

    Al-Shawi, A; Dawnay, A; Landon, J

    1983-01-01

    Rivanol, the cationic salt of an acridine base, has been used as a novel separation procedure in an immunoradiometric assay for human liver ferritin. The separation step is based on the differences in charge and molecular weight between the labelled antibody-ferritin complex and free labelled immunoglobulins. The resultant assay is simple, reproducible and sufficiently sensitive to determine serum concentrations of ferritin.

  9. Nanoparticle-assay marker interaction: effects on nanotoxicity assessment

    International Nuclear Information System (INIS)

    Protein-based cytotoxicity assays such as lactate dehydrogenase (LDH) and tumor necrosis factor-alpha (TNF-α) are commonly used in cytotoxic evaluation of nanoparticles (NPs) despite numerous reports on possible interactions with protein markers in these assays that can confound the results obtained. In this study, conventional cytotoxicity assays where assay markers may (LDH and TNF- α) or may not (PicoGreen and WST-8) come into contact with NPs were used to evaluate the cytotoxicity of NPs. The findings revealed selective interactions between negatively charged protein assay markers (LDH and TNF- α) and positively charged ZnO NPs under abiotic conditions. The adsorption and interaction with these protein assay markers were strongly influenced by surface charge, concentration, and specific surface area of the NPs, thereby resulting in less than accurate cytotoxic measurements, as observed from actual cell viability measurements. An improved protocol for LDH assay was, therefore, proposed and validated by eliminating any effects associated with protein–particle interactions. In view of this, additional measures and precautions should be taken when evaluating cytotoxicity of NPs with standard protein-based assays, particularly when they are of opposite charges

  10. Nanoparticle-assay marker interaction: effects on nanotoxicity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xinxin; Xiong, Sijing; Huang, Liwen Charlotte; Ng, Kee Woei, E-mail: kwng@ntu.edu.sg; Loo, Say Chye Joachim, E-mail: joachimloo@ntu.edu.sg [Nanyang Technological University, School of Materials Science and Engineering (Singapore)

    2015-01-15

    Protein-based cytotoxicity assays such as lactate dehydrogenase (LDH) and tumor necrosis factor-alpha (TNF-α) are commonly used in cytotoxic evaluation of nanoparticles (NPs) despite numerous reports on possible interactions with protein markers in these assays that can confound the results obtained. In this study, conventional cytotoxicity assays where assay markers may (LDH and TNF- α) or may not (PicoGreen and WST-8) come into contact with NPs were used to evaluate the cytotoxicity of NPs. The findings revealed selective interactions between negatively charged protein assay markers (LDH and TNF- α) and positively charged ZnO NPs under abiotic conditions. The adsorption and interaction with these protein assay markers were strongly influenced by surface charge, concentration, and specific surface area of the NPs, thereby resulting in less than accurate cytotoxic measurements, as observed from actual cell viability measurements. An improved protocol for LDH assay was, therefore, proposed and validated by eliminating any effects associated with protein–particle interactions. In view of this, additional measures and precautions should be taken when evaluating cytotoxicity of NPs with standard protein-based assays, particularly when they are of opposite charges.

  11. The effect of gregariousness in cyprid settlement assays

    NARCIS (Netherlands)

    Head, R.M.; Overbeke, J.C.; Klijnstra, J.W.; Biersteker, R.; Thomason, J.C.

    2003-01-01

    The in vitro settlement assay using cyprids of Balanus, amphitrite is an important tool in basic and applied research. The aim of this study was to quantify the effect of gregariousness within these assays, and to determine the interaction between gregariousness and container size, and settlement pr

  12. Maximum information with minimum complexity from a coincidence assay system

    International Nuclear Information System (INIS)

    Nuclear assays based on coincidence measurements can yield more useful information than is usually derived from them. The additional information can be used to improve assay accuracy and reliability with only a modest increase in the complexity of the electronics. A particular three-channel coincidence system that has had practical application is analyzed as an example. (author)

  13. Radioimmunoprecipitation polyethylene glycol assay for circulating Entamoeba histolytica antigens

    Energy Technology Data Exchange (ETDEWEB)

    Pillai, S.; Mohimen, A.; Mehra, S. (Calcutta Medical Research Inst., Calcutta (India). Kothari Centre of Gastroenterology)

    1982-12-17

    An assay capable of detecting circulating Entamoeba histolytica antigens in amoebiasis is described. This assay utilised a radiolabelled affinity purified rabbit anti-E. histolytica antibody that had been depleted of antibodies that cross-react with human serum proteins, and a polyethylene glycol precipitation step.

  14. Usefulness of human coagulation and fibrinolysis assays in domestic pigs

    DEFF Research Database (Denmark)

    Münster, Anna-Marie Bloch; Olsen, Aage Kristian; Bladbjerg, Else-Marie

    2002-01-01

    of commercial human coagulation and fibrinolysis assays for use with porcine plasma. In total, 22 functional and immunologic assays were applied to plasma obtained from domestic pigs, and the following blood coagulation and fibrinolysis variables were measured: prothrombin time, activated partial thromboplastin...... that 11 of 12 functional assays, but only 3 of 10 immunoassays, were applicable to porcine plasma, and we determined the normal range of these variables. We conclude that human functional assays are useful in porcine plasma, whereas only a few immunologic assays can be used. However, precautions must...... be taken in interpretation of the results and in extrapolation toward human results because possible differences between porcine and human values can be due to species variations and/or methodologic errors....

  15. Comparison of immunoturbidimetric and immunonephelometric assays for specific proteins.

    Science.gov (United States)

    Mali, Bahera; Armbruster, David; Serediak, Ernie; Ottenbreit, Tammy

    2009-10-01

    Immunoturbidimetric assays for specific proteins are available on "open system" clinical chemistry analyzers. The analytical performance of nine immunoturbidimetric specific protein assays (C3, C4, CRP, Haptoglobin, IgA, IgG, IgM, RF, and Transferrin) was compared to immunonephelometry. Testing was performed on the Abbott ARCHITECT ci8200 and the Dade Behring BNII nephelometer and evaluated for precision, linearity, limit of detection, prozone phenomenon, method comparison, workflow, and proficiency testing survey comparison. Immunoturbidimetric assays performance was satisfactory for total precision, linearity, limit of detection and the prozone effect was not observed. Method comparison was acceptable for the immunoglobulins, CRP and transferrin but less favorable for the other assays, likely due to methodology and antibody specificity differences. Immunourbidimetric specific protein assays allow for efficient test consolidation on a general purpose clinical chemistry analyzer.

  16. Substrate coated with receptor and labelled ligand for assays

    International Nuclear Information System (INIS)

    Improvements in the procedures for assaying ligands are described. The assay consists of a polystyrene tube on which receptors are present for both the ligand to be assayed and a radioactively labelled form of the ligand. The receptors on the bottom portion of the tube are also coated with labelled ligands, thus eliminating the necessity for separate addition of the labelled ligand and sample during an assay. Examples of ligands to which this method is applicable include polypeptides, nucleotides, nucleosides and proteins. Specific examples are given in which the ligand to be assayed is digoxin, the labelled form of the ligand is 3-0-succinyl digoxyigenin tyrosine (125I) and the receptor is digoxin antibody. (U.K.)

  17. Variance in multiplex suspension array assays: microsphere size variation impact

    Directory of Open Access Journals (Sweden)

    Cheng R Holland

    2007-08-01

    Full Text Available Abstract Background Luminex suspension microarray assays are in widespread use. There are issues of variability of assay readings using this technology. Methods and results Size variation is demonstrated by transmission electron microscopy. Size variations of microspheres are shown to occur in stepwise increments. A strong correspondence between microsphere size distribution and distribution of fluorescent events from assays is shown. An estimate is made of contribution of microsphere size variation to assay variance. Conclusion A probable significant cause of variance in suspended microsphere assay results is variation in microsphere diameter. This can potentially be addressed by changes in the manufacturing process. Provision to users of mean size, median size, skew, the number of standard deviations that half the size range represents (sigma multiple, and standard deviation is recommended. Establishing a higher sigma multiple for microsphere production is likely to deliver a significant improvement in precision of raw instrument readings. Further research is recommended on the molecular architecture of microsphere coatings.

  18. Nondestructive assay instrumentation for Savannah River Plant reprocessing accountability

    International Nuclear Information System (INIS)

    We have designed, developed, and calibrated three different types of nondestructive assay systems for the Savannah River Plant (SRP). These systems will be delivered to SRP in 1986 and become part of the nuclear material accounting instrumentation at one of SRP's reprocessing facilities. Among the various types of nondestructive assay systems to be implemented are a neutron counter (Los Alamos National Laboratory - LANL), a four-station calorimeter (Mound Laboratories), a waste solution assay system (LANL), two gamma-ray solution concentration assay systems (LLNL), two x-ray fluorescence analysis concentration assay systems (LLNL), and one 2-detector plutonium solids isotopics system (LLNL). Los Alamos also has the responsibility of combining the individual measurement systems into an integrated accountability capability. Each NDA instrument will report results to a central Instrument Control Computer (ICC). Figure 1 illustrates schematically the integrated system with each Laboratory's contribution shown by dotted lines

  19. Fast facility spent-fuel and waste assay instrument

    International Nuclear Information System (INIS)

    A delayed-neutron assay instrument was installed in the Fluorinel Dissolution and Fuel Storage Facility at Idaho National Engineering Laboratory. The dual-assay instrument is designed to measure both spent fuel and waste solids that are produced from fuel processing. A set of waste standards, fabricated by Los Alamos using uranium supplied by Exxon Nuclear Idaho Company, was used to calibrate the small-sample assay region of the instrument. Performance testing was completed before installation of the instrument to determine the effects of uranium enrichment, hydrogenous materials, and neutron poisons on assays. The unit was designed to measure high-enriched uranium samples in the presence of large neutron backgrounds. Measurements indicate that the system can assay low-enriched uranium samples with moderate backgrounds if calibrated with proper standards

  20. AFBI assay - Aptamer Fluorescence Binding and Internalization assay for cultured adherent cells.

    Science.gov (United States)

    Thiel, William H; Giangrande, Paloma H

    2016-07-01

    The SELEX (Systematic Evolution of Ligands by Exponential Enrichment) process allows for the enrichment of DNA or RNA aptamers from a complex nucleic acid library that are specific for a target molecule. The SELEX process has been adapted from identifying aptamers in vitro using recombinant target protein to cell-based methodologies (Cell-SELEX), where the targets are expressed on the surface of cells. One major advantage of Cell-SELEX is that the target molecules are maintained in a native confirmation. Additionally, Cell-SELEX may be used to discover novel therapeutic biomarkers by performing selections on diseased versus healthy cells. However, a caveat to Cell-SELEX is that testing of single aptamers identified in the selection is laborious, time-consuming, and expensive. The most frequently used methods to screen for aptamer binding and internalization on cells are flow cytometry and quantitative PCR (qPCR). While flow cytometry can directly assess binding of a fluorescently-labeled aptamer to a target, it requires significant starting material and is not easily scalable. qPCR-based approaches are highly sensitive but have non-negligible experiment-to-experiment variability due to the number of sample processing steps. Herein we describe a cell-based aptamer fluorescence binding and internalization (AFBI) assay. This assay requires minimal reagents and has few experimental steps/manipulations, thereby allowing for rapid screening of many aptamers and conditions simultaneously and direct quantitation of aptamer binding and internalization. PMID:26972784

  1. Comparison of the second-generation digene hybrid capture assay with the branched-DNA assay for measurement of hepatitis B virus DNA in serum

    OpenAIRE

    Ho, Stephen K. N.; Chan, Tak Mao; Cheng, Ignatius K. P.; Lai, Kar Neng

    1999-01-01

    The optimal hepatitis B virus (HBV) DNA quantitative assay for clinical use remains to be determined. We examined the sensitivity, linearity, and variability of a novel second-generation antibody capture solution hybridization assay, the Digene Hybrid Capture II assay (HCII), and compared it with another widely used solution hybridization assay, the branched-DNA (bDNA) assay (Quantiplex; Chiron Corp.). Our results showed similar and satisfactory assay linearity values, as well as interassay a...

  2. Comparison of a Classical Phagocytosis Assay and a Flow Cytometry Assay for Assessment of the Phagocytic Capacity of Sera from Adults Vaccinated with a Pneumococcal Conjugate Vaccine

    OpenAIRE

    Jansen, Wouter T. M.; Väkeväinen-Anttila, Merja; Käyhty, Helena; Nahm, Moon; Bakker, N.; Verhoef, Jan; Snippe, Harm; Verheul, André F. M.

    2001-01-01

    Antibody- and complement-mediated phagocytosis is the main defense mechanism against Streptococcus pneumoniae. A standardized, easy to perform phagocytosis assay for pneumococci would be a great asset for the evaluation of the potential efficacy of (experimental) pneumococcal vaccines. Such an assay could replace the laborious phagocytosis assay of viable pneumococci (classical killing assay). Therefore, a newly developed phagocytosis assay based on flow cytometry (flow assay) was compared wi...

  3. Nondestructive analysis of nuclear materials by isotopic source assay system

    International Nuclear Information System (INIS)

    Destructive assay is an effective method for the analysis of nuclear materials in nuclear fuels, but is not suitable for some aspects of nuclear fuel cycle, for example, for accounting and control or safeguard purposes. Isotopic Source Assay System was imported from Intelcom Rad. Tech. Company, and the results of assay of enriched uranium and plutonium sealed for passive and active assay by the system are presented. A 252Cf source is provided for the assay system. Assay of unknown samples by this system is carried out relatively to the measurement of known standards. Several known standards approximating the physical and chemical properties of unknown samples are prepared to make calibration curves. When one fission event occurs in a sample, a few neutrons (2.5 neutrons on the average) and gamma ray (about 7 photons) are emitted simultaneously. By three detector coincidence out of four, one count is registered by the assay system. First, statistical informations and geometry were examined. Then, three kinds of enriched uranium were measured to examine the measurement on 238U. Passive and active measurements were performed on 4.32 grams of PuO2 during one month to know reproducibility. In conclusion of these tests, it was proved to be able to apply this system to the analysis of nuclear materials similar in enrichment or isotopic composition, and scraps and wastes containing known matrix materials. (Wakatsuki, Y.)

  4. New low-viscosity overlay medium for viral plaque assays

    Directory of Open Access Journals (Sweden)

    Garten Wolfgang

    2006-08-01

    Full Text Available Abstract Background Plaque assays in cell culture monolayers under solid or semisolid overlay media are commonly used for quantification of viruses and antiviral substances. To overcome the pitfalls of known overlays, we tested suspensions of microcrystalline cellulose Avicel RC/CL™ as overlay media in the plaque and plaque-inhibition assay of influenza viruses. Results Significantly larger plaques were formed under Avicel-containing media, as compared to agar and methylcellulose (MC overlay media. The plaque size increased with decreasing Avicel concentration, but even very diluted Avicel overlays (0.3% ensured formation of localized plaques. Due to their low viscosity, Avicel overlays were easier to use than methylcellulose overlays, especially in the 96-well culture plates. Furthermore, Avicel overlay could be applied without prior removal of the virus inoculum thus facilitating the assay and reducing chances of cross-contamination. Using neuraminidase inhibitor oseltamivir carboxylate, we demonstrated applicability of the Avicel-based plaque reduction assay for testing of antiviral substances. Conclusion Plaque assay under Avicel-containing overlay media is easier, faster and more sensitive than assays under agar- and methylcellulose overlays. The assay can be readily performed in a 96-well plate format and seems particularly suitable for high-throughput virus titrations, serological studies and experiments on viral drug sensitivity. It may also facilitate work with highly pathogenic agents performed under hampered conditions of bio-safety labs.

  5. Isolation of Potent CGRP Neutralizing Antibodies Using Four Simple Assays.

    Science.gov (United States)

    Neal, Frances; Arnold, Joanne; Rossant, Christine J; Podichetty, Sadhana; Lowne, David; Dobson, Claire; Wilkinson, Trevor; Colley, Caroline; Howes, Rob; Vaughan, Tristan J

    2016-01-01

    Calcitonin gene-related peptide (CGRP) is a small neuropeptide and a potent vasodilator that is widely associated with chronic pain and migraine. An antibody that inhibits CGRP function would be a potential therapeutic for treatment of these disorders. Here we describe the isolation of highly potent antibodies to CGRP from phage and ribosome display libraries and characterization of their epitope, species cross-reactivity, kinetics, and functional activity. Homogenous time-resolved fluorescence (HTRF) binding assays identified antibodies with the desired species cross-reactivity from naïve libraries, and HTRF epitope competition assays were used to characterize and group scFv by epitope. The functional inhibition of CGRP and species cross-reactivity of purified scFv and antibodies were subsequently confirmed using cAMP assays. We show that epitope competition assays could be used as a surrogate for functional cell-based assays during affinity maturation, in combination with scFv off-rate ranking by biolayer interferometry (BLI). This is the first time it has been shown that off-rate ranking can be predictive of functional activity for anti-CGRP antibodies. Here we demonstrate how, by using just four simple assays, diverse panels of antibodies to CGRP can be identified. These assay formats have potential utility in the identification of antibodies to other therapeutic targets. PMID:26450103

  6. Independency of Fe ions in hemoglobin on immunomagnetic reduction assay

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S.Y. [MagQu Co. Ltd., Sindian City, Taipei County 231, Taiwan (China); Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Lan, C.B.; Chen, C.H. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Horng, H.E. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China)], E-mail: phyfv001@scc.ntnu.edu.tw; Hong, Chin-Yih [Department of Mechanical Engineering, Nan-Kai University of Technology, Nantau County, Taiwan (China)], E-mail: cyhong@nkut.edu.tw; Yang, H.C. [Department of Physics, National Taiwan University, Taipei 106, Taiwan (China)], E-mail: hcyang@phys.ntu.edu.tw; Lai, Y.K. [College of Life Sciences, National Tsing Hua University, Hsinchu City 300, Taiwan (China); Department of Bioresources, Da-Yeh University, Changhua 515, Taiwan (China); Lin, Y.H.; Teng, K.S. [Apex Biotechnology Co. Ltd., Hsinchu City 300, Taiwan (China)

    2009-10-15

    Immunomagnetic reduction (IMR), which involves measuring the reduction in the ac magnetic susceptibility of magnetic reagents, is due to the association between bio-functionalized magnetic nanoparticles and target bio-molecules. This has been demonstrated for assaying proteins in solutions free of Fe ions, such as serum. In this work, the validity of IMR assay for samples rich in Fe ions like hemoglobin (Hb) is investigated. According to the results, there is no magnetic signal contributed by Fe-ion-rich Hb. Furthermore, the results show a high sensitivity in assaying hemoglobin A1c (HbA1c) by using IMR.

  7. A Sensitive Chemotaxis Assay Using a Novel Microfluidic Device

    Directory of Open Access Journals (Sweden)

    Chen Zhang

    2013-01-01

    Full Text Available Existing chemotaxis assays do not generate stable chemotactic gradients and thus—over time—functionally measure only nonspecific random motion (chemokinesis. In comparison, microfluidic technology has the capacity to generate a tightly controlled microenvironment that can be stably maintained for extended periods of time and is, therefore, amenable to adaptation for assaying chemotaxis. We describe here a novel microfluidic device for sensitive assay of cellular migration and show its application for evaluating the chemotaxis of smooth muscle cells in a chemokine gradient.

  8. A Functional Assay for GPR55: Envision Protocol.

    Science.gov (United States)

    Anavi-Goffer, Sharon; Ross, Ruth A

    2016-01-01

    AlphaScreen(®) SureFire(®) assay is a novel technology that combines luminescent oxygen channeling technology, nano-beads, and monocloncal antibodies to detect the level of a selected protein in a volume lower than 5 μl. This method is more sensitive compared with the traditional enzyme-linked immunosorbent assays (ELISA), and can detect an increasing number of new targets. Here, we described a method for AlphaScreen(®) SureFire(®) assay that targets ERK1/2 phosphorylation, a primary downstream signaling pathway that conveys activation of GPR55 by L-α-lysophosphatidylinositol (LPI) and certain cannabinoids. PMID:27245893

  9. Advances in Assays and Analytical Approaches for Botulinum Toxin Detection

    Energy Technology Data Exchange (ETDEWEB)

    Grate, Jay W.; Ozanich, Richard M.; Warner, Marvin G.; Bruckner-Lea, Cindy J.; Marks, James D.

    2010-08-04

    Methods to detect botulinum toxin, the most poisonous substance known, are reviewed. Current assays are being developed with two main objectives in mind: 1) to obtain sufficiently low detection limits to replace the mouse bioassay with an in vitro assay, and 2) to develop rapid assays for screening purposes that are as sensitive as possible while requiring an hour or less to process the sample an obtain the result. This review emphasizes the diverse analytical approaches and devices that have been developed over the last decade, while also briefly reviewing representative older immunoassays to provide background and context.

  10. FLIPR assays of intracellular calcium in GPCR drug discovery

    DEFF Research Database (Denmark)

    Hansen, Kasper Bø; Bräuner-Osborne, Hans

    2009-01-01

    Fluorescent dyes sensitive to changes in intracellular calcium have become increasingly popular in G protein-coupled receptor (GPCR) drug discovery for several reasons. First of all, the assays using the dyes are easy to perform and are of low cost compared to other assays. Second, most non......-Galpha(q)-coupled GPCRs can be tweaked to modulate intracellular calcium by co-transfection with promiscuous or chimeric/mutated G proteins making the calcium assays broadly applicable in GPCR research. Third, the price of instruments capable of measuring fluorescent-based calcium indicators has become significantly less...

  11. Ethanal assay, using an enzymo-conductimetric method

    Energy Technology Data Exchange (ETDEWEB)

    Saad, I.; Wallach, J.M. (I.C.B.M.C., Villeurbanne (France))

    1992-01-01

    An enzymo-conductimetric method for the assay of ethanol is described. It is based on ethanol oxidation is presence of yeast aldehyde dehydrogenase. Experimental conditions compatible with conductimetry were optimized and kinetic parameters of the enzymatic reaction determined. Due to the low K{sub M} value of ethanol for the enzyme, an end-point assay was proposed. A linear relationship was demonstrated between experimental conductance changes and ethanol concentration up to 25 {mu}M. Validation of the assay was made on wines by comparison with a spectrophotometric method. Both methods gave similar results, but conductimetry avoids sample treatment if solutions are colored or turbid.

  12. Detection of hypoxic cells in murine tumors using the comet assay. Comparison with a conventional radiobiological assay

    International Nuclear Information System (INIS)

    The comet (single-cell electrophoresis) assay has been developed as a method for measuring DNA damage in single cells after irradiation. We have developed our own methods and image analysis system for the comet assay to identify hypoxic fractions. In vitro, we tested our system using a cultured tumor cell line (SCCVII). In vivo, we compared the hypoxic fractions detected by this assay with those determined by the in vivo-in vitro clonogenic assay using two rodent tumors (SCCVII/C3H, EMT6/KU/balb/c), which exhibit different types of hypoxia: acute and chronic. In vitro, our method could differentiate hypoxic cells from oxic cells, using the parameter of tail moment. In vivo, there were good correlations between the hypoxic fractions determined by the comet assay and by the clonogenic assay, in SCCVII/C3H (r=0.85) and in EMT6/KU/balb/c (r=0.75) tumors. By comparison of the two methods in chronically hypoxic and acutely hypoxic tumors, we further confirmed that the comet assay is clinically useful for estimating hypoxic fractions of solid tumors. (author)

  13. Evidence of ATP assay as an appropriate alternative of MTT assay for cytotoxicity of secondary effluents from WWTPs.

    Science.gov (United States)

    Yang, Yang; Lu, Yun; Wu, Qian-Yuan; Hu, Hong-Ying; Chen, Ying-Hua; Liu, Wan-Li

    2015-12-01

    Biological tests are effective and comprehensive methods to assess toxicity of environmental pollutants to ensure the safety of reclaimed water. In this study, the canonical MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was performed to evaluate the cytotoxicity of dissolved organic matters (DOMs) of secondary effluents from wastewater treatment plants (WWTPs). It was surprising that most concentrated DOMs treated HepG2 cells yielded much higher signal compared with vehicle control regardless of difference of treatment technologies and seasons. However, there was actually no obvious enhancement of the cell proliferation by microscopy. In order to find out potential reason for the discrepancy, another three assays were performed. The results of ATP assay and flow cytometry showed expected toxicity, which was consistent with microscopy and previous studies, while DNA assay did not exhibit apparent change in treated cells. The possible mechanisms of abnormal MTT signal could be that some materials in secondary effluents isolated by solid extraction with HLB resin directly reacted with MTT and/or enhanced the activity of mitochondrial dehydrogenase. Therefore, the MTT assay is not suitable to assess cytotoxicity of complex mixtures such as secondary effluents, while ATP assay is an optional sensitive method. This study also suggests the importance of choosing both suitable extraction methods and detection assays for toxicity evaluation of component-unknown environmental samples. PMID:26410194

  14. Sperm penetration assay and its correlation with semen analysis parameters

    Directory of Open Access Journals (Sweden)

    Laxmi Kant Pandey

    2015-11-01

    Full Text Available Background: Aim of current study was to determine whether the Sperm Penetration Assay (SPA can be used as a test to discriminate the infertile male from fertile one. We have also correlated the SPA with semen analysis. Methods: Sperm characteristics namely Semen analysis and the sperm penetration assay were tested in 44 infertile and 10 fertile men. Sperm penetration assay was determined by using zona free hamster eggs. Results: With decreasing spermatozoa concentration in the semen there was significant decrease in percentage penetration of zona free Hamster eggs (p0.05. Conclusions: The Sperm penetration assay could discriminate the infertile group from fertile group significantly (p<0.001. The test appeared to be highly reproducible and probably identifies a truly infertile male. [Int J Res Med Sci 2015; 3(11.000: 3197-3201

  15. Test verification and validation for molecular diagnostic assays.

    Science.gov (United States)

    Halling, Kevin C; Schrijver, Iris; Persons, Diane L

    2012-01-01

    With our ever-increasing understanding of the molecular basis of disease, clinical laboratories are implementing a variety of molecular diagnostic tests to aid in the diagnosis of hereditary disorders, detection and monitoring of cancer, determination of prognosis and guidance for cancer therapy, and detection and monitoring of infectious diseases. Before introducing any new test into the clinical laboratory, the performance characteristics of the assay must be "verified," if it is a US Food and Drug Administration (FDA)-approved or FDA-cleared test, or "validated," if it is a laboratory-developed test. Although guidelines exist for how validation and verification studies may be addressed for molecular assays, the specific details of the approach used by individual laboratories is rarely published. Many laboratories, especially those introducing new types of molecular assays, would welcome additional guidance, especially in the form of specific examples, on the process of preparing a new molecular assay for clinical use. PMID:22208481

  16. 384-Well Multiplexed Luminex Cytokine Assays for Lead Optimization.

    Science.gov (United States)

    Tang, Huaping; Panemangalore, Reshma; Yarde, Melissa; Zhang, Litao; Cvijic, Mary Ellen

    2016-07-01

    Cytokines serve as a major mechanism of communication between immune cells and are the functional molecules at the end of immune pathways. Abnormalities in cytokines are involved in a wide variety of diseases, including chronic inflammation, autoimmune diseases, and cancer. Cytokines are not only direct targets of therapeutics but also important biomarkers for assessing drug efficacy and safety. Traditionally, enzyme-linked immunosorbent assays (ELISA) were most popular for identifying and quantifying cytokines. However, ELISA is expensive, labor intensive, and low throughput. Here, we report the development of a miniaturized Luminex (Austin, TX) assay platform to establish a panel of high-throughput, multiplexed assays for measuring cytokines in human whole blood. The miniaturized 384-well Luminex assay uses animal studies and patient samples for translational research. PMID:27095819

  17. Application of neutron multiplicity counting to waste assay

    International Nuclear Information System (INIS)

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A open-quotes tunable multiplicityclose quotes approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions. 9 refs., 6 figs

  18. Assays without Borders - Office of Cancer Clinical Proteomics Research

    Science.gov (United States)

    CPTAC researchers partner with international labs to demonstrate the ability of Targeted mass spectrometry–based assays to reproducibly quantify Human proteins across labs, countries and continents in a recently published journal article.

  19. Cell-based Assays to Identify Inhibitors of Viral Disease

    Science.gov (United States)

    Green, Neil; Ott, Robert D.; Isaacs, Richard J.; Fang, Hong

    2009-01-01

    Background Antagonizing the production of infectious virus inside cells requires drugs that can cross the cell membrane without harming host cells. Objective It is therefore advantageous to establish intracellular potency of anti-viral drug candidates early in the drug-discovery pipeline. Methods To this end, cell-based assays are being developed and employed in high-throughput drug screening, ranging from assays that monitor replication of intact viruses to those that monitor activity of specific viral proteins. While numerous cell-based assays have been developed and investigated, rapid counter screens are also needed to define the specific viral targets of identified inhibitors and to eliminate nonspecific screening hits. Results/Conclusions Here, we describe the types of cell-based assays being used in antiviral drug screens and evaluate the equally important counter screens that are being employed to reach the full potential of cell-based high-throughput screening. PMID:19750206

  20. Click Chemistry-Mediated Nanosensors for Biochemical Assays

    Science.gov (United States)

    Chen, Yiping; Xianyu, Yunlei; Wu, Jing; Yin, Binfeng; Jiang, Xingyu

    2016-01-01

    Click chemistry combined with functional nanoparticles have drawn increasing attention in biochemical assays because they are promising in developing biosensors with effective signal transformation/amplification and straightforward signal readout for clinical diagnostic assays. In this review, we focus on the latest advances of biochemical assays based on Cu (I)-catalyzed 1, 3-dipolar cycloaddition of azides and alkynes (CuAAC)-mediated nanosensors, as well as the functionalization of nanoprobes based on click chemistry. Nanoprobes including gold nanoparticles, quantum dots, magnetic nanoparticles and carbon nanomaterials are covered. We discuss the advantages of click chemistry-mediated nanosensors for biochemical assays, and give perspectives on the development of click chemistry-mediated approaches for clinical diagnosis and other biomedical applications. PMID:27217831

  1. Multiplexed Dosing Assays by Digitally Definable Hydrogel Volumes

    DEFF Research Database (Denmark)

    Faralli, Adele; Melander, Fredrik; Larsen, Esben Kjær Unmack;

    2016-01-01

    Stable and low-cost multiplexed drug sensitivity assays using small volumes of cells or tissue are in demand for personalized medicine, including patientspecific combination chemotherapy. Spatially defined projected light photopolymerization of hydrogels with embedded active compounds is introduced...

  2. Application of neutron multiplicity counting to waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Ensslin, N. [Los Alamos National Lab., NM (United States); Sharpe, T.J. [North Carolina State Univ., Raleigh, NC (United States)

    1997-11-01

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A {open_quotes}tunable multiplicity{close_quotes} approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions. 9 refs., 6 figs.

  3. Piceance Basin Oil Shale Data: Assays, Boreholes and Formation Tops

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This database contains Oil Shale Assays, Borehole Locations and Formation Tops that were used in support of the 2009 Oil Shale Assessment (Survey Fact Sheet...

  4. Radiometric microbiologic assay for the biologically active forms of niacin

    Energy Technology Data Exchange (ETDEWEB)

    Kertcher, J.A.; Guilarte, T.R.; Chen, M.F.; Rider, A.A.; McIntyre, P.A.

    1979-05-01

    A radiometric microbiologic assay has been developed for the determination of niacin in biologic fluids. Lactobacillus plantarum produced /sup 14/CO/sub 2/ from L-(U-/sup 14/C) malic acid in quantities proportional to the amount of niacin present. The assay is specific for the biologically active forms of niacin in humans. Thirty normal hemolysates were analyzed and the values ranged from 13.0 to 17.8 ..mu..g niacin/ml RBC (mean = 15.27 +- 1.33 s.d.). Good recovery and reproducibility studies were obtained with this assay. On thirty blood samples, correlation was excellent between the radiometric and the conventional turbidimetric assays.

  5. Fluorescence Assay for Evaluating Microbicidal Activity of Hand Antiseptics

    OpenAIRE

    Lopez-Gigosos, Rosa M.; Mariscal, Alberto; Mariscal-Lopez, Eloisa; Gutierrez-Bedmar, Mario; Fernandez, Joaquin

    2015-01-01

    We developed a fluorescent β-d-glucuronidase activity (BGA)-based assay for detecting and quantifying Escherichia coli in samples to assess the biocide efficacy of hand antiseptics. The fluorescence level is proportional to the number of viable E. coli organisms present. We compared our assay results to those of the E. coli plate count method specified by the European standard for testing hygienic hand rub disinfectant products (EN1500). The plate count method requires excessive handling and ...

  6. The comet assay – from toy to tool

    OpenAIRE

    Guenter Speit

    2015-01-01

    The comet assay is nowadays the most common method for measuring DNA damage and repair in single cells. It is based on the microelectrophoretic study published by Ostling and Johanson (1984) and was developed by Singh and coworkers (1988) to a versatile technique for quantitation of low levels of DNA damage in individual cells. This alkaline version still is the basis for the triumphant success of the comet assay in basic research into mechanisms of DNA damage and DNA repair, genotoxicity tes...

  7. Comet assay to measure DNA repair: approach and applications

    OpenAIRE

    Azqueta, Amaya; SLYSKOVA, JANA; Langie, Sabine A. S.; O’Neill Gaivão, Isabel; Collins, Andrew

    2014-01-01

    Cellular repair enzymes remove virtually all DNA damage before it is fixed; repair therefore plays a crucial role in preventing cancer. Repair studied at the level of transcription correlates poorly with enzyme activity, and so assays of phenotype are needed. In a biochemical approach, substrate nucleoids containing specific DNA lesions are incubated with cell extract; repair enzymes in the extract induce breaks at damage sites; and the breaks are measured with the comet assay. The nature of ...

  8. Drosophila comet assay: insights, uses, and future perspectives

    OpenAIRE

    Gaivão, Isabel; Sierra, L. María

    2014-01-01

    The comet assay, a very useful tool in genotoxicity and DNA repair testing, is being applied to Drosophila melanogaster since around 15 years ago, by several research groups. This organism is a valuable model for all kind of processes related to human health, including DNA damage response. The assay has been performed mainly in vivo using different larvae cell types (from brain, midgut, hemolymph, and imaginal disk), but also in vitro with the S2 cell line. Since its first application, it has...

  9. A rapid assay for the biological evaluation of helicase activity.

    OpenAIRE

    sprotocols

    2015-01-01

    Authors: Dimitrios Vlachakis, Andrea Brancale, Colin Berry & Sophia Kossida ### Abstract A new assay for the measurement of helicase enzyme activity was developed for the evaluation of the potency of potential inhibitors. This assay involves the use of a DNA or RNA duplex substrate and recombinant purified helicase. The DNA duplex consists of a pair of oligonucleotides, one of which is biotinylated and the other is digoxygenin (DIG)-labelled, both at their respective 5’ termini. T...

  10. Spectrophotometric Assays of Major Compounds Extracted from Algae.

    Science.gov (United States)

    Connan, Solène

    2015-01-01

    This chapter describes spectrophotometric assays of major compounds extracted from microalgae and macroalgae, i.e., proteins, carbohydrates, pigments (chlorophylls, carotenoids, and phycobiliproteins) and phenolic compounds. In contrast to other specific analytical techniques, such as high pressure liquid chromatography (HPLC) or mass spectrometry (MS), commonly applied to purified extracts to reveal more detailed composition and structure of algal compound families, these assays serve as a first assessment of the global contents of extracts.

  11. Predictably irrational: assaying cognitive inflexibility in mouse models of schizophrenia

    OpenAIRE

    Brigman, Jonathan L.

    2010-01-01

    The development of sophisticated, translatable mouse-based assays modeling the behavioral manifestations of neuropsychiatric diseases such as schizophrenia has lagged the advances in molecular and genomic techniques. Our laboratory has made efforts to fill this gap by investing in the development of novel assays, including adapting a touchscreen-based method for measuring cognitive and executive functions for use in mice. As part of these efforts, a recent study by Brigman et al. (2009) inv...

  12. Bioluminescence-Sensing Assay for Microbial Growth Recognition

    OpenAIRE

    Heba Ramadan Eed; Abdel-Kader, Nora S.; Mahmoud Helmy El Tahan; Tianhong Dai; Rehab Amin

    2016-01-01

    The conventional methods for microbial viability quantification require cultivation and are laborious. There is consequently a widespread need for cultivation-free methods. The adenosine triphosphate (ATP) bioluminescence-sensing assay is considered an extremely effective biosensor; hence ATP is the energy currency of all living microbes and can be used as a rapid indicator of microbial viability. We developed an ATP bioluminescence-sensing assay to detect microbial viability. A biolumine...

  13. Reliability of a bioluminescence ATP assay for detection of bacteria.

    OpenAIRE

    Selan, L.; Berlutti, F; Passariello, C.; Thaller, M C; Renzini, G

    1992-01-01

    The reliability of bioluminescence assays which employ the luciferin-luciferase ATP-dependent reaction to evaluate bacterial counts was studied, both in vitro and on urine specimens. Bioluminescence and cultural results for the most common urinary tract pathogens were analyzed. Furthermore, the influence of the culture medium, of the assaying method, and of the phase of growth on bioluminescence readings was studied. Results show that Proteus, Providencia, and Morganella strains are not corre...

  14. Comparison of several fixation methods for cytomegalovirus antigenemia assay.

    OpenAIRE

    Pérez, J.L.; De Oña, M; Niubò, J; Villar, H.; Melón, S.; García, A.; Martín, R.

    1995-01-01

    Two fixation methods based on formaldehyde or acetone for qualitative cytomegalovirus antigenemia assay were evaluated on 405 consecutive blood samples. Cytomegalovirus was detected in 40 samples by the antigenemia assay: 36 were detected by formaldehyde fixation; 22, by acetone; and 18, by both methods. Differences were statistically significant (P = 0.0043). In addition, four fixation methods (two based on formalin [with and without permeabilization] and two using acetone at different fixat...

  15. Diced electrophoresis gel assay for screening enzymes with specified activities.

    Science.gov (United States)

    Komatsu, Toru; Hanaoka, Kenjiro; Adibekian, Alexander; Yoshioka, Kentaro; Terai, Takuya; Ueno, Tasuku; Kawaguchi, Mitsuyasu; Cravatt, Benjamin F; Nagano, Tetsuo

    2013-04-24

    We have established the diced electrophoresis gel (DEG) assay as a proteome-wide screening tool to identify enzymes with activities of interest using turnover-based fluorescent substrates. The method utilizes the combination of native polyacrylamide gel electrophoresis (PAGE) with a multiwell-plate-based fluorometric assay to find protein spots with the specified activity. By developing fluorescent substrates that mimic the structure of neutrophil chemoattractants, we could identify enzymes involved in metabolic inactivation of the chemoattractants.

  16. Delayed Gamma-Ray Assay for Nuclear Safeguards

    OpenAIRE

    Mozin, Vladimir

    2011-01-01

    This dissertation addresses the need for new non-destructive assay instruments capable of quantifying the fissile isotopic composition of spent nuclear fuel and of independently verifying the declared amounts of special nuclear materials at various stages of the nuclear fuel cycle. High-energy delayed gamma-ray spectroscopy can provide the ability to directly assay fissile and fertile isotopes in the highly radioactive environment of the spent fuel assemblies and to achieve the safeguards go...

  17. Multiplex PCR Assay for Identification of Human Diarrheagenic Escherichia coli

    OpenAIRE

    Toma, Claudia; Lu, Yan; Higa, Naomi; Nakasone, Noboru; Chinen, Isabel; Baschkier, Ariela; Rivas, Marta; Iwanaga, Masaaki

    2003-01-01

    A multiplex PCR assay for the identification of human diarrheagenic Escherichia coli was developed. The targets selected for each category were eae for enteropathogenic E. coli, stx for Shiga toxin-producing E. coli, elt and est for enterotoxigenic E. coli, ipaH for enteroinvasive E. coli, and aggR for enteroaggregative E. coli. This assay allowed the categorization of a diarrheagenic E. coli strain in a single reaction tube.

  18. The assay of encapsulated alpha-bearing waste: feasibility study

    International Nuclear Information System (INIS)

    This report contains a review of potentially applicable techniques for the determination of actinide isotopes in radioactive waste and a summary of results obtained with various prototype instruments. A schematic design of a complete assay station is derived with consideration given to practical aspects like remote handling, maintenance etc. and recommendations for further work are made. The place of waste assay in the overall quality assurance of packaged waste is also considered. (author)

  19. Titration of Human Coronaviruses Using an Immunoperoxidase Assay

    OpenAIRE

    Lambert, Francine; Jacomy, Helene; Marceau, Gabriel; J. Talbot, Pierre

    2008-01-01

    Calculation of infectious viral titers represents a basic and essential experimental approach for virologists. Classical plaque assays cannot be used for viruses that do not cause significant cytopathic effects, which is the case for strains 229E and OC43 of human coronavirus (HCoV). An alternative indirect immunoperoxidase assay (IPA) is herein described for the detection and titration of these viruses. Susceptible cells are inoculated with serial logarithmic dilutions of samples in a 96-wel...

  20. Toxicity assays in nanodrops combining bioassay and morphometric endpoints.

    OpenAIRE

    Lemaire, Frédéric; Mandon, Céline A; Reboud, Julien; Papine, Alexandre; Angulo, Jesus; Pointu, Hervé; Diaz-Latoud, Chantal; Lajaunie, Christian; Chatelain, François; Arrigo, André-Patrick; Schaack, Béatrice

    2007-01-01

    BACKGROUND: Improved chemical hazard management such as REACH policy objective as well as drug ADMETOX prediction, while limiting the extent of animal testing, requires the development of increasingly high throughput as well as highly pertinent in vitro toxicity assays. METHODOLOGY: This report describes a new in vitro method for toxicity testing, combining cell-based assays in nanodrop Cell-on-Chip format with the use of a genetically engineered stress sensitive hepatic cell line. We tested ...

  1. Optimising automation of a manual enzyme-linked immunosorbent assay

    OpenAIRE

    Corena de Beer; Monika Esser; Wolfgang Preiser

    2011-01-01

    Objective: Enzyme-linked immunosorbent assays (ELISAs) are widely used to quantify immunoglobulin levels induced by infection or vaccination. Compared to conventional manual assays, automated ELISA systems offer more accurate and reproducible results, faster turnaround times and cost effectiveness due to the use of multianalyte reagents.Design: The VaccZyme™ Human Anti-Haemophilus influenzae type B (Hib) kit (MK016) from The Binding Site Company was optimised to be used on an automated BioRad...

  2. Comparison of three multiplex PCR assays for the detection of respiratory viral infections : evaluation of xTAG respiratory virus panel fast assay, RespiFinder 19 assay and RespiFinder SMART 22 assay

    OpenAIRE

    Dabisch-Ruthe Mareike; Vollmer Tanja; Adams Ortwin; Knabbe Cornelius; Dreier Jens

    2012-01-01

    Abstract Background A broad spectrum of pathogens is causative for respiratory tract infections, but symptoms are mostly similar. Therefore, the identification of the causative viruses and bacteria is only feasible using multiplex PCR or several monoplex PCR tests in parallel. Methods The analytical sensitivity of three multiplex PCR assays, RespiFinder-19, RespiFinder-SMART-22 and xTAG-Respiratory-Virus-Panel-Fast-Assay (RVP), were compared to monoplex real-time PCR with quantified standardi...

  3. Applications of the comet assay in particle toxicology

    DEFF Research Database (Denmark)

    Møller, Peter; Hemmingsen, Jette Gjerke; Jensen, Ditte Marie;

    2015-01-01

    contradictory results dependent on the type of ENM and dose in each set of experiments. In conclusion, the exposure to both combustion-derived particles and ENMs is associated with increased levels of DNA damage in the comet assay. Particle size, composition and crystal structure of ENM are considered important...... determinants of toxicity, whereas their combined contributions to genotoxicity in the comet assay are yet to be thoroughly investigated....

  4. Honey promotes angiogeneic activity in the rat aortic ring assay

    OpenAIRE

    Rossiter, K.; Cooper, Alan; Voegeli, D.; Lwaleed, B.

    2010-01-01

    Objective: To investigate possible effects of honey on angiogenesis, using in vitro analogues of angiogenesis and an endothelial proliferation assay. Method: Using an in vitro rat aortic ring assay we compared pseudotubule formation by medicinal honey (Activon), supermarket honey (Rowse) and a honey-based ointment (Mesitran), with that of artificial honey (70% w/w sugar glucose/fructose). Pseudotubules were analysed using TCS Cellworks AngioSys software. The Angiokit sytem was used to validat...

  5. Honey promotes angiogenic activity in the rat aortic ring assay

    OpenAIRE

    Rossiter, K.; Cooper, A. J.; Voegeli, D.; Lwaleed, B A

    2010-01-01

    Objective: To investigate possible effects of honey on angiogenesis, using in vitro analogues of angiogenesis and an endothelial proliferation assay. Method: Using an in vitro rat aortic ring assay we compared pseudotubule formation by medicinal honey (Activon), supermarket honey (Rowse) and a honey-based ointment (Mesitran), with that of artificial honey (70% w/w sugar glucose/fructose). Pseudotubules were analysed using TCS Cellworks AngioSys software. The Angiokit sytem was used t...

  6. The estimation of serological assays for latent syphilis patients

    OpenAIRE

    Ozoliņš, Dzintars

    2010-01-01

    The estimation of serological assays for latent syphilis patients Abstract The aim of the current investigation is to evaluate how informative are serological assays for syphilis screening, the confirmation diagnosis of the late latent syphilis and for monitoring of the serological activity and treatment efficacy. Conclusions SED, TPHA, ELISA IgG, IgM and syphilis imunoblot IgG are useful for the late latent syphilis screening diagnostics. We do not recommend to use RPR for thi...

  7. Enzyme-linked immunosorbent assay for shigella toxin.

    OpenAIRE

    Donohue-Rolfe, A; Kelley, M A; Bennish, M; Keusch, G T

    1986-01-01

    An enzyme-linked immunosorbent assay (ELISA) was developed for the detection of shigella toxin. For the assay, a mouse monoclonal antibody against the B subunit of the toxin and a rabbit polyclonal antibody against the holotoxin were employed. The monoclonal antibody was used to coat wells of a microtiter plate, and the polyclonal antibody preparation was used as the detecting antibody. The amount of bound polyclonal antibody was determined by using a goat anti-rabbit immunoglobulin G-alkalin...

  8. A radioreceptor assay for pharmaceutical preparations of insulin

    International Nuclear Information System (INIS)

    A radioreceptor assay has been developed that is suitable for the measurement of the potency of crystalline insulin and pharmaceutical insulin formulations. It utilizes the well characterized and widely available IM-9 human lymphocyte cell line as the source of receptor. Bovine, porcine and human crystalline and formulated insulins have been assayed against the 4th International and European Standards for Insulin and the potencies compared with those obtained by the mouse blood glucose method. Results with bovine insulin were in full correspondence with the in vivo results. Porcine and human insulins were 15-20% more potent by the radioreceptor assay than by the in vivo method when the mixed bovine and porcine insulin 4th International and European Standards were used, but were equivalent when compared with like materials. Average 95% confidence limits for formulated insulins in two assays were +-6% of the mean. The coefficient of variation on repeated assay of the same sample was 3.8%. The three dose parallel line radioreceptor assay with appropriate species standards is a candidate biological test capable of international adoption as an alternative to in vivo animal testing of insulin. (author)

  9. Semiconductor Electronic Label-Free Assay for Predictive Toxicology

    Science.gov (United States)

    Mao, Yufei; Shin, Kyeong-Sik; Wang, Xiang; Ji, Zhaoxia; Meng, Huan; Chui, Chi On

    2016-01-01

    While animal experimentations have spearheaded numerous breakthroughs in biomedicine, they also have spawned many logistical concerns in providing toxicity screening for copious new materials. Their prioritization is premised on performing cellular-level screening in vitro. Among the screening assays, secretomic assay with high sensitivity, analytical throughput, and simplicity is of prime importance. Here, we build on the over 3-decade-long progress on transistor biosensing and develop the holistic assay platform and procedure called semiconductor electronic label-free assay (SELFA). We demonstrate that SELFA, which incorporates an amplifying nanowire field-effect transistor biosensor, is able to offer superior sensitivity, similar selectivity, and shorter turnaround time compared to standard enzyme-linked immunosorbent assay (ELISA). We deploy SELFA secretomics to predict the inflammatory potential of eleven engineered nanomaterials in vitro, and validate the results with confocal microscopy in vitro and confirmatory animal experiment in vivo. This work provides a foundation for high-sensitivity label-free assay utility in predictive toxicology. PMID:27117746

  10. Crystal Violet and XTT Assays on Staphylococcus aureus Biofilm Quantification.

    Science.gov (United States)

    Xu, Zhenbo; Liang, Yanrui; Lin, Shiqi; Chen, Dingqiang; Li, Bing; Li, Lin; Deng, Yang

    2016-10-01

    Staphylococcus aureus (S. Aureus) is a common food-borne pathogenic microorganism. Biofilm formation remains the major obstruction for bacterial elimination. The study aims at providing a basis for determining S. aureus biofilm formation. 257 clinical samples of S. aureus isolates were identified by routine analysis and multiplex PCR detection and found to contain 227 MRSA, 16 MSSA, 11 MRCNS, and 3 MSCNS strains. Two assays for quantification of S. aureus biofilm formation, the crystal violet (CV) assay and the XTT (tetrazolium salt reduction) assay, were optimized, evaluated, and further compared. In CV assay, most isolates formed weak biofilm 74.3 %), while the rest formed moderate biofilm (23.3 %) or strong biofilm (2.3 %). However, most isolates in XTT assay showed weak metabolic activity (77.0 %), while the rest showed moderate metabolic activity (17.9 %) or high metabolic activity (5.1 %). In this study, we found a distinct strain-to-strain dissimilarity in terms of both biomass formation and metabolic activity, and it was concluded from this study that two assays were mutual complementation rather than being comparison. PMID:27324342

  11. First 25-hydroxyvitamin D assay for general chemistry analyzers.

    Science.gov (United States)

    Saida, Fakhri B; Chen, Xiaoru; Tran, Kiet; Dou, Chao; Yuan, Chong

    2015-03-01

    25-Hydroxyvitamin D [25(OH)D], the predominant circulating form of vitamin D, is an accurate indicator of the general vitamin D status of an individual. Because vitamin D deficiencies have been linked to several pathologies (including osteoporosis and rickets), accurate monitoring of 25(OH)D levels is becoming increasingly important in clinical settings. Current 25(OH)D assays are either chromatographic or immunoassay-based assays. These assays include HPLC, liquid chromatography-tandem mass spectrometry (LC-MS/MS), enzyme-immunosorbent, immunochemiluminescence, immunofluorescence and radioimmunoassay. All these assays use heterogeneous formats that require phase separation and special instrumentations. In this article, we present an overview of these assays and introduce the first homogeneous assay of 25(OH)D for use on general chemistry analyzers. A special emphasis is put on the unique challenges posed by the 25(OH)D analyte. These challenges include a low detection limit, the dissociation of the analyte from its serum transporter and the inactivation of various binding proteins without phase separation steps.

  12. Development and Evaluation of a Novel Taqman Real-Time PCR Assay for Rapid Detection of Mycoplasma bovis: Comparison of Assay Performance with a Conventional PCR Assay and Another Taqman Real-Time PCR Assay

    Directory of Open Access Journals (Sweden)

    Hemant Naikare

    2015-03-01

    Full Text Available The objective of this study was to develop and validate a Taqman real-time PCR assay for the detection of Mycoplasma bovis (M. bovis. Unique primers targeting the highly conserved house-keeping gene (uvrC were designed and the probe sequence was derived from a previously published microarray study. There was 100% agreement in the outcome between our assay and the other two published assays for M. bovis detection. The analytical limit of detection of our assay is 83 copies of the uvrC gene. This assay was validated on a total of 214 bovine clinical specimens that were submitted to the Texas A&M Veterinary Medical Diagnostic Laboratory (TVMDL, Texas, USA. The specificity of the assay was assessed to be 100% since no cross-reactivity occurred with 22 other bacterial and other Mycoplasma species. We conclude that the uvrC gene serves as a good and reliable diagnostic marker for the accurate and rapid detection of M. bovis from a wider variety of specimen matrices.

  13. A colorimetric sandwich-type assay for sensitive thrombin detection based on enzyme-linked aptamer assay.

    Science.gov (United States)

    Park, Jun Hee; Cho, Yea Seul; Kang, Sungmuk; Lee, Eun Jeong; Lee, Gwan-Ho; Hah, Sang Soo

    2014-10-01

    A colorimetric sandwich-type assay based on enzyme-linked aptamer assay has been developed for the fast and sensitive detection of as low as 25 fM of thrombin with high linearity. Aptamer-immobilized glass was used to capture the target analyte, whereas a second aptamer, functionalized with horseradish peroxidase (HRP), was employed for the conventional 3,5,3',5'-tetramethylbenzidine (TMB)-based colorimetric detection. Without the troublesome antibody requirement of the conventional enzyme-linked immunosorbent assay (ELISA), as low as 25 fM of thrombin could be rapidly and reproducibly detected. This assay has superior, or at least equal, recovery and accuracy to that of conventional antibody-based ELISA.

  14. Vitellogenin assay by enzyme-linked immunosorbant assay as a biomarker of endocrine disruptor chemicals pollution

    Directory of Open Access Journals (Sweden)

    Ebrahimi M

    2005-01-01

    Full Text Available There is increasing evidence that many xenobiotic chemicals (called as endocrine disruptor chemicals, EDCs through interfering with the endocrine system, have the capability to induce developmental and reproductive abnormalities in humans and animals. The yolk protein precursor vitellogenin (Vtg has proved to be a simple and sensitive biomarker for assessing exposure of fish to EDCs, especially the estrogenic compounds. Work is ongoing to develop screening and testing programmes for endocrine disrupting effects of new chemicals, and in the focus of this development are the fish test species common carp ( Cyprinus carpio . In this study, we have developed quantitative enzyme-linked immunosorbent assays (ELISA for VTS in common carp. The working range of the ELISA was 11.25 - 2000 ng/ml (75 - 25% specific binding/maximum antibody binding [B/B0] with a 50% B/B0 intra and interassay variation of 3.9% ( n = 10 and 12.5% ( n = 30, respectively. This ELISA is capable of detecting Vtg as low as 6 ng/ml, and can accurately detect Vtg in even 10 ml of plasma. The ELISA was applied to measurement of Vtg production by male carp ( C. carpio , Cyprinidae fish exposure to ethynylestradiol. The results showed that the amount of Vtg produced in plasma of exposed fish increased in logarithmic order comparing to the control group and the ELISA described here could be used as an indicator of water pollution to estrogenic pollutants.

  15. Hemizona Assay and Sperm Penetration Assay in the Prediction of IVF Outcome: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Paraskevi Vogiatzi

    2013-01-01

    Full Text Available The limited predictive value of semen analysis in achieving natural conception or in IVF outcome confirms the need for sperm function tests to determine optimal management. We reviewed HZA and SPA predictive power in IVF outcome, with statistical significance of diagnostic power of the assays. HZA was readily efficient in predicting IVF outcome, while evident inconsistency among the studies analysed framed the SPA’s role in male fertility evaluation. Considerable variation was noted in the diagnostic accuracy values of SPA with wide sensitivity (52–100%, specificity (0–100%, and PPV (18–100% and NPV (0–100% together with fluctuation and notable differentiation in methodology and cutoff values employed by each group. HZA methodology was overall consistent with minor variation in cutoff values and oocyte source, while data analysis reported strong correlation between HZA results with IVF outcome, high sensitivity (75–100%, good specificity (57–100%, and high PPV (79–100% and NPV (68–100%. HZA correlated well with IVF outcome and demonstrated better sensitivity/specificity and positive/negative predictive power. Males with normal or slightly abnormal semen profiles could benefit by this intervention and could be evaluated prior to referral to assisted reproduction. HZA should be used in a sequential fashion with semen analysis and potentially other bioassays in an IVF setting.

  16. A comparison of immunoenzymometric assays for human thyroid stimulating hormone and human growth hormone with established immunoradiometric assay methodology

    International Nuclear Information System (INIS)

    Two-site immunoenzymometric assays (IEMAs) utilizing polyclonal antisera coated microtitre well (solid phase) and horse radish peroxidase labelled murine monoclonal antibody (MAb) have been developed with a view to supplying a non-radioisotopic immunoassay system for use in a bulk matched reagent scheme. A two state assay format with a spectrophotometric end point readout was chosen. Results for the pituitary hormones human thyroid stimulating hormone (hTSH) and human growth hormone (hGH) are presented. Assay characteristics and performance of these IEMAs compared favourably with existing immunoradiometric assays (IRMAs) which use microcrystalline cellulose coupled solid phase antibody and 125I labelled MAb. Intra-assay analytical precision was similar for both hTSH methods but slightly worse for the hGH IEMA. Relative to IRMA, mean IEMA sensitivity was better for the hTSH, but worse for hGH. However, ''working ranges'' with analytical imprecision of less than 10% covered the distribution of standards in all assays. Good agreement was obtained between methods for patient hTSH specimens up to 12.5 mIU/L but a concentration-dependent negative bias developed in the IEMA at higher hTSH levels. A similar bias was observed in the hGH IEMA. The bias was traced to a ''matrix effect'' due to the hTSH-free horse serum used to prepare standards. (author). 15 refs, 5 figs, 1 tab

  17. Neutron Resonance Transmission Analysis (NRTA): A Nondestructive Assay Technique for the Next Generation Safeguards Initiative’s Plutonium Assay Challenge

    Energy Technology Data Exchange (ETDEWEB)

    J. W. Sterbentz; D. L. Chichester

    2010-12-01

    This is an end-of-year report for a project funded by the National Nuclear Security Administration's Office of Nuclear Safeguards (NA-241). The goal of this project is to investigate the feasibility of using Neutron Resonance Transmission Analysis (NRTA) to assay plutonium in commercial light-water-reactor spent fuel. This project is part of a larger research effort within the Next-Generation Safeguards Initiative (NGSI) to evaluate methods for assaying plutonium in spent fuel, the Plutonium Assay Challenge. The first-year goals for this project were modest and included: 1) developing a zero-order MCNP model for the NRTA technique, simulating data results presented in the literature, 2) completing a preliminary set of studies investigating important design and performance characteristics for the NRTA measurement technique, and 3) documentation of this work in an end of the year report (this report). Research teams at Los Alamos National Laboratory (LANL), Lawrence Berkeley National Laboratory (LBNL), Pacific Northwest National Laboratory (PNNL), and at several universities are also working to investigate plutonium assay methods for spent-fuel safeguards. While the NRTA technique is well proven in the scientific literature for assaying individual spent fuel pins, it is a newcomer to the current NGSI efforts studying Pu assay method techniques having just started in March 2010; several analytical techniques have been under investigation within this program for two to three years or more. This report summarizes a nine month period of work.

  18. Suitability of a liquid chromatography assay of neomycin sulfate to replace the microbiological assay for neomycin in USP Monographs.

    Science.gov (United States)

    Hanko, Valoran P; Rohrer, Jeffrey S

    2010-01-01

    The current USP National Formulary contains 65 Monographs for drug formulations containing neomycin. All 65 Monographs prescribe a bioassay for neomycin assay. This bioassay, based on cell culture, is labor intensive, has poor precision, and cannot be adapted for purity or identification. High-performance anion-exchange chromatography with integrated pulsed amperometric detection (HPAE-IPAD), a liquid chromatography technique, has been shown to be suitable for neomycin purity analysis and neomycin assay of an over-the-counter first aid cream (Hanko and Rohrer [17]). Here we propose that an HPAE-IPAD assay can replace the bioassay in the 65 neomycin-containing Monographs. We applied the HPAE-IPAD assay to four neomycin-containing drug products representing the four classes of formulations found in the 65 Monographs, liquid, solid, suspension, and cream. Each drug was analyzed with two chromatography systems, and on 3 separate days. For all products, HPAE-IPAD measurements were precise and accurate with respect to the label concentrations. There was also high accuracy for spike recovery of neomycin from the four drug products throughout 70-150% of the labeled concentration. These results suggest that an HPAE-IPAD assay would be an accurate assay for neomycin, and would be faster and more precise than the current bioassay.

  19. Multiplexed Recombinase Polymerase Amplification Assay To Detect Intestinal Protozoa.

    Science.gov (United States)

    Crannell, Zachary; Castellanos-Gonzalez, Alejandro; Nair, Gayatri; Mejia, Rojelio; White, A Clinton; Richards-Kortum, Rebecca

    2016-02-01

    This work describes a proof-of-concept multiplex recombinase polymerase amplification (RPA) assay with lateral flow readout that is capable of simultaneously detecting and differentiating DNA from any of the diarrhea-causing protozoa Giardia, Cryptosporidium, and Entamoeba. Together, these parasites contribute significantly to the global burden of diarrheal illness. Differential diagnosis of these parasites is traditionally accomplished via stool microscopy. However, microscopy is insensitive and can miss up to half of all cases. DNA-based diagnostics such as polymerase chain reaction (PCR) are far more sensitive; however, they rely on expensive thermal cycling equipment, limiting their availability to centralized reference laboratories. Isothermal DNA amplification platforms, such as the RPA platform used in this study, alleviate the need for thermal cycling equipment and have the potential to broaden access to more sensitive diagnostics. Until now, multiplex RPA assays have not been developed that are capable of simultaneously detecting and differentiating infections caused by different pathogens. We developed a multiplex RPA assay to detect the presence of DNA from Giardia, Cryptosporidium, and Entamoeba. The multiplex assay was characterized using synthetic DNA, where the limits-of-detection were calculated to be 403, 425, and 368 gene copies per reaction of the synthetic Giardia, Cryptosporidium, and Entamoeba targets, respectively (roughly 1.5 orders of magnitude higher than for the same targets in a singleplex RPA assay). The multiplex assay was also characterized using DNA extracted from live parasites spiked into stool samples where the limits-of-detection were calculated to be 444, 6, and 9 parasites per reaction for Giardia, Cryptosporidium, and Entamoeba parasites, respectively. This proof-of-concept assay may be reconfigured to detect a wide variety of targets by re-designing the primer and probe sequences.

  20. Epithelial cells as alternative human biomatrices for comet assay

    Directory of Open Access Journals (Sweden)

    Emilio eRojas

    2014-11-01

    Full Text Available The comet assay is a valuable experimental tool aimed at mapping DNA damage in human cells in vivo for environmental and occupational monitoring, as well as for therapeutic purposes, such as storage prior to transplant, during tissue engineering, and in experimental ex vivo assays. Furthermore, due to its great versatility, the comet assay allows to explore the use of alternative cell types to assess DNA damage, such as epithelial cells. Epithelial cells, as specialized components of many organs, have the potential to serve as biomatrices that can be used to evaluate genotoxicity and may also serve as early effect biomarkers. Furthermore, 80% of solid cancers are of epithelial origin, which points to the importance of studying DNA damage in these tissues. Indeed, studies including comet assay in epithelial cells have either clear clinical applications (lens and corneal epithelial cells or examine genotoxicity within human biomonitoring and in vitro studies. We here review improvements in determining DNA damage using the comet assay by employing lens, corneal, tear duct, buccal, and nasal epithelial cells. For some of these tissues invasive sampling procedures are needed. Desquamated epithelial cells must be obtained and dissociated prior to examination using the comet assay, and such procedures may induce varying amounts of DNA damage. Buccal epithelial cells require lysis enriched with proteinase K to obtain free nucleosomes.Over a thirty year period, the comet assay in epithelial cells has been litlle employed, however its use indicates that it could be an extraordinary tool not only for risk assessment, but also for diagnosis, prognosis of treatments and diseases.

  1. Comparison of clonogenic assay with premature chromosome condensation assay in prediction of human cell radiosensitivity

    Institute of Scientific and Technical Information of China (English)

    Zhuan-Zi Wang; Wen-Jian Li; Hong Zhang; Jian-She Yang; Rong Qiu; Xiao Wang

    2006-01-01

    AIM: To determine whether the number of non-rejoining G2-chromatid breaks can predict the radiosensitivity of human cell lines.METHODS: Cell lines of human ovary carcinoma cells (HO8910), human hepatoma cells (HepG2) and liver cells (L02) were irradiated with a range of doses and assessed both of cell survival and non-rejoining G2-chromatid breaks at 24 h after irradiation. Cell survival was documented by a colony assay. Non-rejoining G2-chromatid breaks were measured by counting the number of non-rejoining G2 chromatid breaks at 24 h after irradiation, detected by the prematurely chromosome condensed (PCC) technique.RESULTS: A linear-quadratic survival curve was observed in three cell lines, and HepG2 was the most sensitive to y-radiation. A dose-dependent linear increase was observed in radiation-induced non-rejoining G2-PCC breaks measured at 24 h after irradiation in all cell lines, and HepG2 was the most susceptible to induction of non-rejoining G2-PCC breaks. A close correlation was found between the clonogenic radiosensitivity and the radiation-induced non-rejoining G2-PCC breaks (r= 0.923). Furthermore, survival-aberration correlations for two or more than two doses lever were also significant.CONCLUSION: The number of non-rejoining G2 PCC breaks holds considerable promise for predicting the radiosensitivity of normal and tumor cells when two or more than two doses lever is tested.

  2. The comet assay in testing the potential genotoxicity of nanomaterials

    Directory of Open Access Journals (Sweden)

    Amaya Azqueta

    2015-06-01

    Full Text Available In the last two decades the production and use of nanomaterials (NMs has impressively increased. Their small size, given a mass equal to that of the corresponding bulk material, implies an increase in the surface area and consequently in the number of atoms that can be reactive. They possess different physical, chemical and biological properties compared to bulk materials of the same composition, which makes them very interesting and valuable for many different applications in technology, energy, construction, electronics, agriculture, optics, paints, textiles, food, cosmetics, medicine... Toxicological assessment of NMs is crucial; the same properties that make them interesting also make them potentially harmful for health and the environment. However, the term NM covers many different kinds of particle , and so there is no simple, standard approach to assessing their toxicity. NMs can enter the cell, interact with cell components and even penetrate the nucleus and interfere with the genetic material. Among the different branches of toxicology, genotoxicity is a main area of concern since it is closely related with the carcinogenic potential of compounds. The Organisation for Economic Co-operation and Development (OECD has published internationally agreed in vitro and in vivo validated test methods to evaluate different genotoxic endpoints of chemicals, including chromosome and gene mutations, and DNA breaks. However not all the assays are suitable to study the genotoxic potential of NMs as has been shown by the OECD Working Party on Manufactured Nanomaterials (WPMN. Moreover, alterations to DNA bases, which are precursors to mutations and of great importance in elucidating the mechanism of action of NMs, are not covered by the OECD guidelines. The in vivo standard comet assay (which measures DNA breaks and alkali-labile sites was included in the OECD assays battery in September 2014 while the in vitro standard comet assay is currently under

  3. Irradiation detection of food by DNA Comet Assay

    International Nuclear Information System (INIS)

    Microgel electrophoresis of single cells or nuclei (DNA Comet Assay) has been investigated to detect irradiation treatment of more than 50 food commodities e.g. meats, seafood, cereals, pulses, nuts, fruits and vegetables, and spices. The foodstuffs have been exposed to radiation doses covering the range of potential commercial irradiation for inactivation of pathogenic and spoilage micro-organisms, for insect disinfestation and for shelf-life extension. The Comet Assay is based on detection of DNA fragments presumptive to irradiation. For most of the food items investigated, the assay can be applied successfully for irradiation detection by working out different conditions of the assay. However, with some of the foods difficulties arose due to - lack of discrimination between the irradiated and unirradiated food samples due to the presence of the same kinds of comets in both cases and the total absence of the typical intact cells in unirradiated samples. - Sufficient DNA material was not available from some of the foods. - Insufficient lysis of the cell walls in case of some plant foods. In conclusion, the DNA Comet Assay can help to detect the irradiation treatment of several varieties of foods using low-cost equipment in a short time of analysis. (orig.)

  4. The use of comet assay in plant toxicology: recent advances

    Directory of Open Access Journals (Sweden)

    Conceição LV Santos

    2015-06-01

    Full Text Available The systematic study of genotoxicity in plants induced by contaminants and other stress agents has been hindered to date by the lack of reliable and robust biomarkers. The comet assay is a versatile and sensitive method for the evaluation of DNA damages and DNA repair capacity at single-cell level. Due to its simplicity and sensitivity, and the small number of cells required to obtain robust results, the use of plant comet assay has drastically increased in the last decade. For years its use was restricted to a few model species, e.g. Allium cepa, Nicotiana tabacum, Vicia faba, or Arabidopsis thaliana but this number largely increased in the last years. Plant comet assay has been used to study the genotoxic impact of radiation, chemicals including pesticides, phytocompounds, heavy metals, nanoparticles or contaminated complex matrices. Here we will review the most recent data on the use of this technique as a standard approach for studying the genotoxic effects of different stress conditions on plants. Also, we will discuss the integration of information provided by the comet assay with other DNA-damage indicators, and with cellular responses including oxidative stress, cell division or cell death. Finally, we will focus on putative relations between transcripts related with DNA damage pathways, DNA replication and repair, oxidative stress and cell cycle progression that have been identified in plant cells with comet assays demonstrating DNA damage.

  5. Parallel force assay for protein-protein interactions.

    Directory of Open Access Journals (Sweden)

    Daniela Aschenbrenner

    Full Text Available Quantitative proteome research is greatly promoted by high-resolution parallel format assays. A characterization of protein complexes based on binding forces offers an unparalleled dynamic range and allows for the effective discrimination of non-specific interactions. Here we present a DNA-based Molecular Force Assay to quantify protein-protein interactions, namely the bond between different variants of GFP and GFP-binding nanobodies. We present different strategies to adjust the maximum sensitivity window of the assay by influencing the binding strength of the DNA reference duplexes. The binding of the nanobody Enhancer to the different GFP constructs is compared at high sensitivity of the assay. Whereas the binding strength to wild type and enhanced GFP are equal within experimental error, stronger binding to superfolder GFP is observed. This difference in binding strength is attributed to alterations in the amino acids that form contacts according to the crystal structure of the initial wild type GFP-Enhancer complex. Moreover, we outline the potential for large-scale parallelization of the assay.

  6. A novel fluorescence-based cellular permeability assay.

    Science.gov (United States)

    Chandra, Ankur; Barillas, Samuel; Suliman, Ahmed; Angle, Niren

    2007-04-10

    Vascular permeability is a pathologic process in many disease states ranging from metastatic progression of malignancies to ischemia-reperfusion injury. In order to more precisely study tissue, and more specifically cell layer permeability, our goal was to create a fluorescence-based assay which could quantify permeability without radioactivity or electrical impedance measurements. Human aortic endothelial cells were grown in monolayer culture on Costar-Transwell clear polyester membrane 6-well cell culture inserts. After monolayer integrity was confirmed, vascular endothelial growth factor (VEGF(165)) at varying concentrations with a fixed concentration of yellow-green fluorescent 0.04 microm carboxylate-modified FluoSpheres microspheres were placed in the luminal chamber and incubated for 24 h. When stimulated with VEGF(165) at 20, 40, 80, and 100 ng/ml, this assay system was able to detect increases in trans-layer flux of 8.2+/-2.4%, 16.0+/-3.7%, 41.5+/-4.9%, and 58.6+/-10.1% for each concentration, respectively. This represents the first fluorescence-based permeability assay with the sensitivity to detect changes in the permeability of a cell layer to fluid flux independent of protein flux; as well as being simpler and safer than previous radioactive-and impedance-based permeability assays. With the application of this in vitro assay to a variety of pathologic conditions, both the dynamics and physiology relating to cellular permeability can be more fully investigated. PMID:16962665

  7. Specific binding-adsorbent assay method and test means

    International Nuclear Information System (INIS)

    A description is given of an improved specific binding assay method and test means employing a nonspecific adsorbent for the substance to be determined, particularly hepatitis B surface (HBsub(s)) antigen, in its free state or additionally in the form of its immune complex. The invention is illustrated by 1) the radioimmunoadsorbent assay for HBsub(s) antigen, 2) the radioimmunoadsorbent assay for HBsub(s) antigen in the form of immune complex with antibody, 3) a study of adsorption characteristics of various anion exchange materials for HBsub(s) antigen, 4) the use of hydrophobic adsorbents in a radioimmunoadsorbent assay for HBsub(s) antigen and 5) the radioimmunoadsorbent assay for antibody to HBsub(s) antigen. The advantages of the present method for detecting HBsub(s) antigen compared to previous methods include the manufacturing advantages of eliminating the need for insolubilised anti-HBsub(s) and the advantages of a single incubation step, fewer manipulations, storability of adsorbent materials, increased sensitivity and versatility of detecting HBsub(s) antigen in the form of its immune complex if desired. (U.K.)

  8. A highly scalable peptide-based assay system for proteomics.

    Directory of Open Access Journals (Sweden)

    Igor A Kozlov

    Full Text Available We report a scalable and cost-effective technology for generating and screening high-complexity customizable peptide sets. The peptides are made as peptide-cDNA fusions by in vitro transcription/translation from pools of DNA templates generated by microarray-based synthesis. This approach enables large custom sets of peptides to be designed in silico, manufactured cost-effectively in parallel, and assayed efficiently in a multiplexed fashion. The utility of our peptide-cDNA fusion pools was demonstrated in two activity-based assays designed to discover protease and kinase substrates. In the protease assay, cleaved peptide substrates were separated from uncleaved and identified by digital sequencing of their cognate cDNAs. We screened the 3,011 amino acid HCV proteome for susceptibility to cleavage by the HCV NS3/4A protease and identified all 3 known trans cleavage sites with high specificity. In the kinase assay, peptide substrates phosphorylated by tyrosine kinases were captured and identified by sequencing of their cDNAs. We screened a pool of 3,243 peptides against Abl kinase and showed that phosphorylation events detected were specific and consistent with the known substrate preferences of Abl kinase. Our approach is scalable and adaptable to other protein-based assays.

  9. Evaluation of a radioreceptor assay for TSH receptor autoantibodies

    Energy Technology Data Exchange (ETDEWEB)

    Rootwelt, K.

    1988-02-01

    A commercial radioreceptor assay for TSH receptor autoantibodies (TRAb), based on solubilized porcine receptor and purified radio-iodinated bovine TSH, was tested in 264 subjects with a variety of thyroid disorders. The sensitivity of the assay for the detection of hyperthyroid Graves' disease was 91%. The assay specificity for Graves' disease was 95%. With the exception of one patient with Hashimoto's disease and one patient with de Quervain's subacute thyroiditis no subjects other than Graves' patients had detectable TRAb. Thus purely blocking TSII receptor autoantibodies were not detected with the assay. One female with thyroxine-treated idiopathic primary hypothyroidism who had given birth to two children with transiently elevated TSH, was found to have a circulating TSH-binding substance that resulted in an abnormally negative TRAb value, and highly discrepant results when TSH was measured with a double antibody TSH radioimmunoassay and an immunoradiometric assay. The TSH-binding substance was precipitated like a protein, but was not IgG. Similar findings have not previously been reported.

  10. Non-Destructive Assay of Curium Contaminated Transuranic Waste Drums

    Energy Technology Data Exchange (ETDEWEB)

    Foster, L.A.

    1998-11-01

    At the Plutonium Facility at Los Alamos National Laboratory, a series of non-destructive assays were performed on five transuranic waste (TRU) drums containing non-plutonium scrap metal that was potentially contaminated with weapons grade plutonium and trace quantities of curium. Typically, waste drums containing metal matrices are assayed for plutonium content using passive neutron coincidence counting techniques. The presence of trace quantities of Cm-244 prevents this type of analysis because of the strong coincidence signal created by spontaneous fission of Cm-244. To discriminate between the plutonium and curium materials present, an active neutron measurement technique was used. A Cf shuffler designed for measurement of uranium bearing materials was calibrated for plutonium in the active mode. The waste drums were then assayed for plutonium content in the shuffler using the active-mode calibration. The curium contamination levels were estimated from the difference between the active-mode measurement in the shuffler and a passive assay in a neutron coincidence counter. Far field gamma-ray measurements were made to identify additional radioactive contaminants and to corroborate the plutonium measurement results obtained from the active-mode assay. This report describes in detail the measurement process used for characterization of these waste drums. The measurement results and the estimated uncertainty will be presented.

  11. An improved europium release assay for complement-mediated cytolysis.

    Science.gov (United States)

    Cui, J; Bystryn, J C

    1992-02-14

    An improved assay for complement-mediated cytolysis is described. The target cells are labeled with europium complexed to diethylenetriaminopentaacetate (Eu-DTPA). Cytolysis caused by antibody plus complement leads to the release of the Eu-DTPA complex which is then formed into a highly fluorescent chelate by the addition of 2-naphthoyltrifluoroacetone (2-NTA). The amount of europium chelate formed--a measurement of cell death--is then quantified with a time-resolved fluorometer. The results of the assay are reproducible. Complement-mediated cytolysis when measured by europium release was five times more sensitive than when measured by conventional 51Cr release and three times than when measured by trypan blue exclusion. Because europium does not decay, target cells can be labelled in batches and stored frozen until use, which speeds and simplifies the assay. Thus, europium release assay is a simple and quantitative method to measure complement-mediated cytolysis which is sensitive and more rapid than conventional assays. PMID:1541836

  12. Assaying Predatory Feeding Behaviors in Pristionchus and Other Nematodes.

    Science.gov (United States)

    Lightfoot, James W; Wilecki, Martin; Okumura, Misako; Sommer, Ralf J

    2016-01-01

    This protocol provides multiple methods for the analysis and quantification of predatory feeding behaviors in nematodes. Many nematode species including Pristionchus pacificus display complex behaviors, the most striking of which is the predation of other nematode larvae. However, as these behaviors are absent in the model organism Caenorhabditis elegans, they have thus far only recently been described in detail along with the development of reliable behavioral assays (1). These predatory behaviors are dependent upon phenotypically plastic but fixed mouth morphs making the correct identification and categorization of these animals essential. In P. pacificus there are two mouth types, the stenostomatous and eurystomatous morphs (2), with only the wide mouthed eurystomatous containing an extra tooth and being capable of killing other nematode larvae. Through the isolation of an abundance of size matched prey larvae and subsequent exposure to predatory nematodes, assays including both "corpse assays" and "bite assays" on correctly identified mouth morph nematodes are possible. These assays provide a means to rapidly quantify predation success rates and provide a detailed behavioral analysis of individual nematodes engaged in predatory feeding activities. In addition, with the use of a high-speed camera, visualization of changes in pharyngeal activity including tooth and pumping dynamics are also possible. PMID:27684744

  13. Enzyme-Linked Immunosorbent Assay for Immunoglobulin G Antibody to Encephalomyocarditis Virus

    OpenAIRE

    Shanley, John D.

    1980-01-01

    An enzyme-linked immunosorbent assay for immunoglobulin G antibody to encephalomyocarditis virus was developed. This assay was comparable to antibody assay by neutralization. Its adaptability should be useful for laboratory and epidemiological studies of infections due to encephalomyocarditis virus.

  14. Qualification of standard membrane-feeding assay with Plasmodium falciparum malaria and potential improvements for future assays.

    Directory of Open Access Journals (Sweden)

    Kazutoyo Miura

    Full Text Available Vaccines that interrupt malaria transmission are of increasing interest and a robust functional assay to measure this activity would promote their development by providing a biologically relevant means of evaluating potential vaccine candidates. Therefore, we aimed to qualify the standard membrane-feeding assay (SMFA. The assay measures the transmission-blocking activity of antibodies by feeding cultured P. falciparum gametocytes to Anopheles mosquitoes in the presence of the test antibodies and measuring subsequent mosquito infection. The International Conference on Harmonisation (ICH Harmonised Tripartite Guideline Q2(R1 details characteristics considered in assay validation. Of these characteristics, we decided to qualify the SMFA for Precision, Linearity, Range and Specificity. The transmission-blocking 4B7 monoclonal antibody was tested over 6 feeding experiments at several concentrations to determine four suitable concentrations that were tested in triplicate in the qualification experiments (3 additional feeds to evaluate Precision, Linearity and Range. For Specificity, 4B7 was tested in the presence of normal mouse IgG. We determined intra- and inter-assay variability of % inhibition of mean oocyst intensity at each concentration of 4B7 (lower concentrations showed higher variability. We also showed that % inhibition was dependent on 4B7 concentration and the activity is specific to 4B7. Since obtaining empirical data is time-consuming, we generated a model using data from all 9 feeds and simulated the effects of different parameters on final readouts to improve the assay procedure and analytical methods for future studies. For example, we estimated the effect of number of mosquitoes dissected on variability of % inhibition, and simulated the relationship between % inhibition in oocyst intensity and % inhibition of prevalence of infected mosquitos at different mean oocysts in the control. SMFA is one of the few biological assays used in

  15. Evaluation of five hepatitis delta virus marker assays for detection of antigen and antibody.

    OpenAIRE

    Bezeaud, A; Rosenswajg, M; Guillin, M C

    1989-01-01

    Five commercially available assays for hepatitis delta (HD) virus markers were compared for sensitivity, specificity, and reproducibility: three assays for antibody (anti-HD), provided by Diagnostics Pasteur, Organon Teknika, and Abbott Laboratories, and two assays for antigen (HD Ag), from Pasteur and Organon Teknika. The assay from Organon Teknika is the less sensitive assay for anti-HD detection. Although the sensitivities of the Pasteur and Abbott assays for anti-HD detection are similar,...

  16. The comet assay – how to recognise “good data”

    OpenAIRE

    William Barfield

    2015-01-01

    Testing of potentially genotoxic materials currently involves use of in vitro assays such as the Ames test (gene mutations), the chromosome aberration assay and in vitro micronucleus assay (predominantly using human peripheral lymphocytes to detect clastogenicity and/or aueuploidy) and the mouse lymphoma assay (gene mutations). In addition, one in vivo assay, predominately the in vivo micronucleus assay, is “normally” required to satisfy regulatory testing requirements and on occasion a secon...

  17. Endotoxin contamination of enzyme conjugates used in enzyme-linked immunosorbent assays.

    OpenAIRE

    Bryant, R. E.; Chamovitz, B N; Morse, S A; Apicella, M A; Morthland, V H

    1983-01-01

    The specificity of the enzyme-linked immunosorbent assay(s) is thought to depend on the specificity of the antibody used in the assay system. Therefore, the association of broadly reactive antigens like endotoxin with enzyme conjugates or other enzyme-linked immunosorbent assay reagents has the potential of altering the specificity of reactions in the enzyme-linked immunosorbent assay. Using the Limulus amoebocyte lysate assay, we demonstrated that commercially prepared conjugates of goat ant...

  18. Optimization of protein samples for NMR using thermal shift assays.

    Science.gov (United States)

    Kozak, Sandra; Lercher, Lukas; Karanth, Megha N; Meijers, Rob; Carlomagno, Teresa; Boivin, Stephane

    2016-04-01

    Maintaining a stable fold for recombinant proteins is challenging, especially when working with highly purified and concentrated samples at temperatures >20 °C. Therefore, it is worthwhile to screen for different buffer components that can stabilize protein samples. Thermal shift assays or ThermoFluor(®) provide a high-throughput screening method to assess the thermal stability of a sample under several conditions simultaneously. Here, we describe a thermal shift assay that is designed to optimize conditions for nuclear magnetic resonance studies, which typically require stable samples at high concentration and ambient (or higher) temperature. We demonstrate that for two challenging proteins, the multicomponent screen helped to identify ingredients that increased protein stability, leading to clear improvements in the quality of the spectra. Thermal shift assays provide an economic and time-efficient method to find optimal conditions for NMR structural studies. PMID:26984476

  19. Evaluation of a visualization assay for blood on forensic evidence.

    Science.gov (United States)

    Vandewoestyne, Mado; Lepez, Trees; Van Hoofstat, David; Deforce, Dieter

    2015-05-01

    In forensics, bloodstains on dark fabrics might be invisible for the naked eye. Although several visualization, presumptive, and confirmatory blood tests have been developed, all have one or more disadvantages, especially on DNA analysis. We report here the use of a visualization assay that can visually detect blood drops up to 1/20 dilution. In this assay, the fabric is placed between two wet filter papers and covered by glass surfaces on both sides. Pressure is applied on the glass surfaces in which bloodstains transfer onto the filter papers through capillary forces. Detected stains can be tested with other more sensitive presumptive blood tests performed on the filter paper. Even more, DNA analysis can be performed on the transferred bloodstains. The presented visualization assay is easy to perform, extremely cheap, requires little hands on time, and does not affect bloodstain pattern analysis.

  20. Functional assay of the alternative complement pathway of rat serum

    International Nuclear Information System (INIS)

    Two functional assays of the alternative pathway of complement activation in rat serum were developed. In the first assay, conditions were established for titration of alternative pathway activity by use of the 50% hemolytic end-point of rabbit red blood cells (RaRBC) in serum treated with ethyleneglycol-bis-(beta-aminoethyl ether)-N, N'-tetraacetic acid (EGTA). The second assay of alternative pathway activity was based on the opsonization of heat-killed radiolabeled pneumococci of serotype 25 (Pn25). Opsonization of Pn25 was shown to proceed entirely via the alternative pathway in rat serum. There was excellent correlation between the results obtained with the RaRBC lysis test and those obtained with the opsonization test. Because of its technical simplicity, the RaRBC lysis test appeared to be the single most useful test of alternative pathway activity in rat serum. (Auth.)

  1. Field-based multiplex and quantitative assay platforms for diagnostics

    Science.gov (United States)

    Venkatasubbarao, Srivatsa; Dixon, C. Edward; Chipman, Russell; Scherer, Axel; Beshay, Manal; Kempen, Lothar U.; Chandra Sekhar, Jai Ganesh; Yan, Hong; Puccio, Ava; Okonkwo, David; McClain, Stephen; Gilbert, Noah; Vyawahare, Saurabh

    2011-06-01

    The U.S. military has a continued interest in the development of handheld, field-usable sensors and test kits for a variety of diagnostic applications, such as traumatic brain injury (TBI) and infectious diseases. Field-use presents unique challenges for biosensor design, both for the readout unit and for the biological assay platform. We have developed robust biosensor devices that offer ultra-high sensitivity and also meet field-use needs. The systems under development include a multiplexed quantitative lateral flow test strip for TBI diagnostics, a field test kit for the diagnosis of pathogens endemic to the Middle East, and a microfluidic assay platform with a label-free reader for performing complex biological automated assays in the field.

  2. NASOPHARYNGEAL CARCINOMA RADIOSENSITIVITY PREDICTION BY CYTOKINESIS—BLOCK MICRONUCLEUS ASSAY

    Institute of Scientific and Technical Information of China (English)

    杨星; 史剑慧; 等

    1995-01-01

    Cytokinesis-block micronucleus method is used to evaluate the radiosensityvity of a nasopharyngeal carcinoma cell line(CNE-1) and biopsies obtained from 31 patients with nasopharyngeal carcinoma,The number of micronuclei increases with the radiation dose.A good correlation was found between the radiosensitivity determined by the micro-nucleus assay and that measured by the colony-forming assay in CNE-1 cell line(r=-0.998).Moreover,the results of micronucleus assay for tumor cells from biopsies of patients with primary carcinoma look promising for the prediction of tumor radiosensitivity.These results are encouraging but need to be confirmed with a larger number of patients with a longer follow-up.

  3. Lactate dehydrogenase assay for assessment of polycation cytotoxicity

    DEFF Research Database (Denmark)

    Parhamifar, Ladan; Andersen, Helene; Moghimi, Seyed Moien

    2013-01-01

    Cellular toxicity and/or cell death entail complex mechanisms that require detailed evaluation for proper characterization. A detailed mechanistic assessment of cytotoxicity is essential for design and construction of more effective polycations for nucleic acid delivery. A single toxicity assay...... cannot stand alone in determining the type and extent of damage or cell death mechanism. In this chapter we describe a lactate dehydrogenase (LDH) assay for high-throughput screening that can be used as a starting point for further detailed cytotoxicity determination. LDH release is considered an early...... event in necrosis but a late event in apoptosis. An accurate temporal assessment of the toxic responses is crucial as late apoptosis may convert into necrosis as well as in situations where cell death is initiated without any visible cell morphological changes or responses in assays measuring late...

  4. Application of statistical process control to qualitative molecular diagnostic assays

    LENUS (Irish Health Repository)

    O'Brien, Cathal P.

    2014-11-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  5. Protein subcellular localization assays using split fluorescent proteins

    Science.gov (United States)

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2009-09-08

    The invention provides protein subcellular localization assays using split fluorescent protein systems. The assays are conducted in living cells, do not require fixation and washing steps inherent in existing immunostaining and related techniques, and permit rapid, non-invasive, direct visualization of protein localization in living cells. The split fluorescent protein systems used in the practice of the invention generally comprise two or more self-complementing fragments of a fluorescent protein, such as GFP, wherein one or more of the fragments correspond to one or more beta-strand microdomains and are used to "tag" proteins of interest, and a complementary "assay" fragment of the fluorescent protein. Either or both of the fragments may be functionalized with a subcellular targeting sequence enabling it to be expressed in or directed to a particular subcellular compartment (i.e., the nucleus).

  6. Development of robotic plasma radiochemical assays for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Alexoff, D.L.; Shea, C.; Fowler, J.S.; Gatley, S.J.; Schlyer, D.J. [Brookhaven National Lab., Upton, NY (United States). Dept. of Chemistry

    1995-12-01

    A commercial laboratory robot system (Zymate PyTechnology II Laboratory Automation System; Zymark Corporation, Hopkinton, MA) was interfaced to standard and custom laboratory equipment and programmed to perform rapid radiochemical analyses for quantitative PET studies. A Zymark XP robot arm was used to carry out the determination of unchanged (parent) radiotracer in plasma using only solid phase extraction methods. Robotic throughput for the assay of parent radiotracer in plasma is 4--6 samples/hour depending on the radiotracer. Robotic assays of parent compound in plasma were validated for the radiotracers [{sup 11}C]Benztropine, [{sup 11}C]cocaine, [{sup 11}C]clorgyline, [{sup 11}C]deprenyl, [{sup 11}C]methadone, [{sup 11}C]methylphenidate, [{sup 11}C]raclorpride, and [{sup 11}C]SR46349B. A simple robot-assisted methods development strategy has been implemented to facilitate the automation of plasma assays of new radiotracers.

  7. Kynetic resazurin assay (KRA) for bacterial quantification of foodborne pathogens

    Science.gov (United States)

    Arenas, Yaxal; Mandel, Arkady; Lilge, Lothar

    2012-03-01

    Fast detection of bacterial concentrations is important for the food industry and for healthcare. Early detection of infections and appropriate treatment is essential since, the delay of treatments for bacterial infections tends to be associated with higher mortality rates. In the food industry and in healthcare, standard procedures require the count of colony-forming units in order to quantify bacterial concentrations, however, this method is time consuming and reports require three days to be completed. An alternative is metabolic-colorimetric assays which provide time efficient in vitro bacterial concentrations. A colorimetric assay based on Resazurin was developed as a time kinetic assay (KRA) suitable for bacterial concentration measurements. An optimization was performed by finding excitation and emission wavelengths for fluorescent acquisition. A comparison of two non-related bacteria, foodborne pathogens Escherichia coli and Listeria monocytogenes, was performed in 96 well plates. A metabolic and clonogenic dependence was established for fluorescent kinetic signals.

  8. Lipase assay in duodenal juice using a conductimetric method.

    Science.gov (United States)

    Ballot, C; Favre-Bonvin, G; Wallach, J M

    1984-11-15

    Lipase activity in duodenal juice is known to undergo important variations in pathologic states, especially in cases of chronic pancreatitis. Almost all of the current assay methods are based on the measurement of hydrolysis of olive oil or triolein, mainly by potentiometry. As we have developed a conductimetric method for enzyme activity measurements, we have applied it to lipase assay. A higher experimental conductimetric sensitivity is obtained when liberated acids have a short chain (higher limiting equivalent conductivity). We have therefore used triacetin as a substrate and compared out method with potentiometry (pH-stat) and spectrophotometry. The correlation coefficients of both methods with conductimetry were 0.94 and 0.97, respectively, indicating that the conductimetric method may be used for lipase assay in duodenal juice, using triacetin as a substrate.

  9. Development of robotic plasma radiochemical assays for positron emission tomography

    International Nuclear Information System (INIS)

    A commercial laboratory robot system (Zymate PyTechnology II Laboratory Automation System; Zymark Corporation, Hopkinton, MA) was interfaced to standard and custom laboratory equipment and programmed to perform rapid radiochemical analyses for quantitative PET studies. A Zymark XP robot arm was used to carry out the determination of unchanged (parent) radiotracer in plasma using only solid phase extraction methods. Robotic throughput for the assay of parent radiotracer in plasma is 4--6 samples/hour depending on the radiotracer. Robotic assays of parent compound in plasma were validated for the radiotracers [11C]Benztropine, [11C]cocaine, [11C]clorgyline, [11C]deprenyl, [11C]methadone, [11C]methylphenidate, [11C]raclorpride, and [11C]SR46349B. A simple robot-assisted methods development strategy has been implemented to facilitate the automation of plasma assays of new radiotracers

  10. Reference cells and ploidy in the comet assay

    Directory of Open Access Journals (Sweden)

    Gunnar eBrunborg

    2015-02-01

    Full Text Available In the comet assay, single cells are analyzed with respect to their level of DNA damage. Discrimination of the individual cell or cell type based on DNA content, with concomitant scoring of the DNA damage, is useful since this may allow analysis of mixtures of cells. Different cells can then be characterized based on their ploidy, cell cycle stage, or genome size. We here describe two applications of such a cell type-specific comet assay: (i Testicular cell suspensions, analyzed on the basis of their ploidy during spermatogenesis; and (ii reference cells in the form of fish erythrocytes which can be included as internal standards to correct for inter-assay variations. With standard fluorochromes used in the comet assay, the total staining signal from each cell – whether damaged or undamaged – was found to be associated with the cell’s DNA content. Analysis of the fluorescence intensity of single cells is straightforward since these data are available in scoring systems based on image analysis. The analysis of testicular cell suspensions provides information on cell type specific composition, susceptibility to genotoxicants, and DNA repair. Internal reference cells, either untreated or carrying defined numbers of lesions induced by ionizing radiation, are useful for investigation of experimental factors that can cause variation in comet assay results, and for routine inclusion in experiments to facilitate standardization of methods and comparison of comet assay data obtained in different experiments or in different laboratories. They can also be used - in combination with a reference curve - to quantify the DNA lesions induced by a certain treatment. Fish cells of a range of genome sizes, both greater and smaller than human, are suitable for this purpose and they are inexpensive.

  11. A high-throughput chemically induced inflammation assay in zebrafish

    Directory of Open Access Journals (Sweden)

    Liebel Urban

    2010-12-01

    Full Text Available Abstract Background Studies on innate immunity have benefited from the introduction of zebrafish as a model system. Transgenic fish expressing fluorescent proteins in leukocyte populations allow direct, quantitative visualization of an inflammatory response in vivo. It has been proposed that this animal model can be used for high-throughput screens aimed at the identification of novel immunomodulatory lead compounds. However, current assays require invasive manipulation of fish individually, thus preventing high-content screening. Results Here we show that specific, noninvasive damage to lateral line neuromast cells can induce a robust acute inflammatory response. Exposure of fish larvae to sublethal concentrations of copper sulfate selectively damages the sensory hair cell population inducing infiltration of leukocytes to neuromasts within 20 minutes. Inflammation can be assayed in real time using transgenic fish expressing fluorescent proteins in leukocytes or by histochemical assays in fixed larvae. We demonstrate the usefulness of this method for chemical and genetic screens to detect the effect of immunomodulatory compounds and mutations affecting the leukocyte response. Moreover, we transformed the assay into a high-throughput screening method by using a customized automated imaging and processing system that quantifies the magnitude of the inflammatory reaction. Conclusions This approach allows rapid screening of thousands of compounds or mutagenized zebrafish for effects on inflammation and enables the identification of novel players in the regulation of innate immunity and potential lead compounds toward new immunomodulatory therapies. We have called this method the chemically induced inflammation assay, or ChIn assay. See Commentary article: http://www.biomedcentral.com/1741-7007/8/148.

  12. Recombinase Polymerase Amplification Assay for Rapid Diagnostics of Dengue Infection.

    Directory of Open Access Journals (Sweden)

    Ahmed Abd El Wahed

    Full Text Available Over 2.5 billion people are exposed to the risk of contracting dengue fever (DF. Early diagnosis of DF helps to diminish its burden on public health. Real-time reverse transcription polymerase amplification assays (RT-PCR are the standard method for molecular detection of the dengue virus (DENV. Real-time RT-PCR analysis is not suitable for on-site screening since mobile devices are large, expensive, and complex. In this study, two RT-recombinase polymerase amplification (RT-RPA assays were developed to detect DENV1-4.Using two quantitative RNA molecular standards, the analytical sensitivity of a RT-RPA targeting the 3´non-translated region of DENV1-4 was found to range from 14 (DENV4 to 241 (DENV1-3 RNA molecules detected. The assay was specific and did not cross detect other Flaviviruses. The RT-RPA assay was tested in a mobile laboratory combining magnetic-bead based total nucleic acid extraction and a portable detection device in Kedougou (Senegal and in Bangkok (Thailand. In Kedougou, the RT-RPA was operated at an ambient temperature of 38 °C with auxiliary electricity tapped from a motor vehicle and yielded a clinical sensitivity and specificity of 98% (n=31 and 100% (n=23, respectively. While in the field trial in Bangkok, the clinical sensitivity and specificity were 72% (n=90 and 100%(n=41, respectively.During the first 5 days of infection, the developed DENV1-4 RT-RPA assays constitute a suitable accurate and rapid assay for DENV diagnosis. Moreover, the use of a portable fluorescence-reading device broadens its application potential to the point-of-care for outbreak investigations.

  13. Quantitative detection of RT activity by PERT assay: feasibility and limits to a standardized screening assay for human vaccines.

    Science.gov (United States)

    André, M; Morgeaux, S; Fuchs, F

    2000-06-01

    The detection of adventitious retroviruses has always been critical for assessing the safety concerns associated with viral vaccines. Assays for the enzymatic activity of reverse transcriptase (RT) are used as general methods for the detection of both known and unknown retroviruses. Several studies using newly-developed ultrasensitive PCR-based RT assays reported RT activity in viral vaccines grown in chicken cells. Here, we have assessed the performances of such a PCR-based RT assay--PERT assay--for the quantitative detection of RT activity in vaccines. Sensitivity, linearity and reproducibility of the method were studied on purified RT and viral vaccines treated to release RT from potentially contaminant retroviruses. The level of RT activity detected in chicken cell-derived vaccines was higher for live attenuated vaccines compared to inactivated ones. Contrary to other studies, RT activity was found in some mammalian cell-derived vaccines. AZT-TP sensitivity of RT activities detected in these vaccines and discrimination between retroviral and RT-like activities was further investigated. Feasibility and limits of PERT assay as a broad-spectrum retroviruses detection method in vaccines are discussed.

  14. Establishment of an Enzyme Linked Immunosorbent Assay for Albumin

    International Nuclear Information System (INIS)

    A sensitive and specific ELISA for Albumin was established by using Albumin antibody coated on the microtiter plate, Albumin labeled horseradish peroxidase(HRP). The sensitivity of the assay was 0.28 mg/L. The intra-and inter-assay CVs were 2.63%-5.28% and 2.40%-4.26% respectively. The analytical recovery was 95.0%-106.4%, the coefficient correlation was 0.9974. This method for measuring Alb was rapid, sensitive and convenient. It is suitable for clinical detection and research application. (authors)

  15. Development of ELISA and immunochromatographic assay for ofloxacin

    Institute of Scientific and Technical Information of China (English)

    Wu Yong Sun; Wen Ying Liu; Ling Bo Qu

    2007-01-01

    Two rapid, sensitive and reliable immunoassay methods, namely competitive indirect enzyme-linked immunosorbent assay (CIELISA) and colloidal gold-based immunochromatographic assay (CGIA), were developed to detect ofloxacin (OFL). The linear range of the CI-ELISA was from 0.5 to 128 ng/mL with a limit of detection (LOD) of 0.35 ng/mL. Good recoveries were obtained in analyzing simulated swine urine samples. The CGIA could accurately estimate OFL at concentrations as low as 10 ng/mL in less than 10 min, and test results were read visually without any instrument.

  16. Genotoxicity Assessment of Erythritol by Using Short-term Assay

    OpenAIRE

    Chung, Young-Shin; Lee, Michael

    2013-01-01

    Erythritol is a sugar alcohol that is widely used as a natural sugar substitute. Thus, the safety of its usage is very important. In the present study, short-term genotoxicity assays were conducted to evaluate the potential genotoxic effects of erythritol. According to the OECD test guidelines, the maximum test dose was 5,000 μg/plate in bacterial reverse mutation tests, 5,000 μg/ml in cell-based assays, and 5,000 mg/kg for in vivo testing. An Ames test did not reveal any positive results. No...

  17. The use of comet assay in plant toxicology: recent advances

    OpenAIRE

    Santos, Conceição L. V.; Pourrut, Bertrand; Ferreira de Oliveira, José M. P.

    2015-01-01

    The systematic study of genotoxicity in plants induced by contaminants and other stress agents has been hindered to date by the lack of reliable and robust biomarkers. The comet assay is a versatile and sensitive method for the evaluation of DNA damages and DNA repair capacity at single-cell level. Due to its simplicity and sensitivity, and the small number of cells required to obtain robust results, the use of plant comet assay has drastically increased in the last decade. For years its use ...

  18. Reference cells and ploidy in the comet assay

    OpenAIRE

    Brunborg, Gunnar; Collins, Andrew; Graupner, Anne; Gutzkow, Kristine B.; Olsen, Ann-Karin

    2015-01-01

    In the comet assay single cells are analyzed with respect to their level of DNA damage. Discrimination of the individual cell or cell type based on DNA content, with concomitant scoring of the DNA damage, is useful since this may allow analysis of mixtures of cells. Different cells can then be characterized based on their ploidy, cell cycle stage, or genome size. We here describe two applications of such a cell type-specific comet assay: (i) Testicular cell suspensions, analyzed on the basis ...

  19. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  20. On the search for an intelligible comet assay descriptor

    OpenAIRE

    Møller, Peter; Loft, Steffen; Ersson, Clara; Koppen, Gudrun; Dusinska, Maria; Collins, Andrew

    2014-01-01

    The comet assay has developed over the past 30 years and today, a variety of different DNA lesions and DNA repair can be measured by different versions of the assay (Collins, 2004). In the final step of the method, an image resembling a comet with a head (the nuclear core) and a tail (consisting of mainly single stranded DNA that has migrated out from the cell nuclei) is analyzed. The magnitude of the comet's DNA-tail provides information about the level of DNA lesions in the cell. The result...

  1. Isotopic methods or immuno diagnosis: The Radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    This work offers an explanation about the more used isotopic techniques for immuno diagnosis: the radioimmunoassay (RIA) and immunoradiometric assay (IRMA). It describes the basic principles of these assays, the antigen-antibody reaction, the radioiodination methods with I-125 for antigens and antibodies, the purification and characterization of labelled compounds. On the order hand they present work gives a review of the methods for separate the bound and free fractions. At the end it offers the principles of the quality control of immunoassay and the future lines of research in the field of RIA and IRMA

  2. Maximum information with minimum complexity from a coincidence assay system

    International Nuclear Information System (INIS)

    There are nuclear based assay situations where measurement of coincident radiation is possible and also appropriate because the coincidence requirement serves to decrease background and moreover may be particularly characteristic of the material being assayed. In these cases, besides the basic coincidence response, the coincidence system can be made to furnish additional useful information, to reduce the sensitivity of the measurement to detection efficiency, provide a continuous test of system performance, and in some instances, signal the presence of environmental noise or nuclear interferences. This paper discusses this coincidence system further. 3 refs., 1 fig

  3. A Colloidal Stability Assay Suitable for High-Throughput Screening.

    Science.gov (United States)

    Abarca, Carla; Ali, M Monsur; Yang, Songtao; Dong, Xiaofei; Pelton, Robert H

    2016-03-01

    A library of 32 polystyrene copolymer latexes, with diameters ranging between 53 and 387 nm, was used to develop and demonstrate a high-throughput assay using a 96-well microplate platform to measure critical coagulation concentrations, a measure of colloidal stability. The most robust assay involved an automated centrifugation-decantation step to remove latex aggregates before absorbance measurements, eliminating aggregate interference with optical measurements made through the base of the multiwell plates. For smaller nanoparticles (diameter aggregation; however, the results were less sensitive than the absorbance measurements. PMID:26857643

  4. Spontaneous and cytokine induced basophil adhesion evaluated by microtiter assay

    DEFF Research Database (Denmark)

    Quan, Sha; Poulsen, Lars K; Reimert, Claus Michael;

    2002-01-01

    We have developed a microtiter assay for evaluating basophil spontaneous adhesion to extracellular matrix (ECM) proteins exemplified by fibronectin and cytokine induced basophil adhesion to bovine serum albumin (BSA). The percentage of basophils adhering to either ECM or BSA was quantified by the...... increased with time between 5 and 45 min. The histamine release in both spontaneous and induced basophil adhesion was lower than 3.1%. This microtiter assay is simple and reproducible and can be applied for basic and clinical studies using a limited number of partially purified basophils....

  5. Use of laminar flow patterning for miniaturised biochemical assays

    DEFF Research Database (Denmark)

    Regenberg, Birgitte; Krühne, Ulrich; Beyer, M.;

    2004-01-01

    Laminar flow in microfluidic chambers was used to construct low (one dimensional) density arrays suitable for miniaturized biochemical assays. By varying the ratio of flows of two guiding streams flanking a sample stream, precise focusing and positioning of the latter was achieved, and reactive s...... species carried in the sample stream were deposited on functionalized chip surfaces as discrete 50 mm wide lanes. Using different model systems we have confirmed the method's suitability for qualitative screening and quantification tasks in receptor-ligand assays, recording biotin...

  6. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas

    2013-10-22

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  7. Assessing equivalence of two assays using sensitivity and specificity.

    Science.gov (United States)

    Quiroz, Jorge; Burdick, Richard K

    2007-01-01

    The equivalence of two assays is determined using the sensitivity and specificity relative to a gold standard. The equivalence-testing criterion is based on a misclassification rate proposed by Burdick et al. (2005) and the intersection-union test (IUT) method proposed by Berger (1982). Using a variance components model and IUT methods, we construct bounds for the sensitivity and specificity relative to the gold standard assay based on generalized confidence intervals. We conduct a simulation study to assess whether the bounds maintain the stated test size. We present a computational example to demonstrate the method described in the paper.

  8. Measuring MAP kinase activity in immune complex assays.

    Science.gov (United States)

    Cherkasova, Vera A

    2006-11-01

    I present an overview of published methods for measuring mitogen activated protein (MAP) kinase activity on endogenous associated substrates, exogenously added substrates as well as determination of activation loop phosphorylation as a read-out of kinase activity in vivo. Detailed procedures for these assays are given for two MAP kinases (MAPKs) Fus3 and Kss1 and compared with other published protocols, including the protocols for Hog1 and Mpk1 MAPKs. Measuring kinase activity in immune complex assays can serve as an approach for identification of potential substrates of protein kinases as well as for detecting other kinase-associated proteins. PMID:16890454

  9. Comparison of automated von Willebrand factor activity assays

    DEFF Research Database (Denmark)

    Timm, Annette; Hillarp, Andreas; Philips, Malou;

    2015-01-01

    INTRODUCTION: Von Willebrand Disease (VWD) is the most common inherited bleeding disorder. Measurement of von Willebrand factor (VWF) activity in plasma is often based on platelet agglutination stimulated by the ristocetin cofactor activity. Novel assays, based on latex beads with recombinant...

  10. Opsonophagocytic Assay To Evaluate Immunogenicity of Nontyphoidal Salmonella Vaccines.

    Science.gov (United States)

    Ramachandran, Girish; Boyd, Mary Adetinuke; MacSwords, Jennifer; Higginson, Ellen E; Simon, Raphael; Galen, James E; Pasetti, Marcela F; Levine, Myron M; Tennant, Sharon M

    2016-06-01

    Nontyphoidal Salmonella (NTS) invasive infections are an important cause of morbidity and mortality in sub-Saharan Africa. Several vaccines are in development to prevent these infections. We describe an NTS opsonophagocytic killing assay that uses HL-60 cells and baby rabbit complement to quantify functional antibodies elicited by candidate NTS vaccines. PMID:27030587

  11. Improved assay for measuring heparin binding to bull sperm

    International Nuclear Information System (INIS)

    The binding of heparin to sperm has been used to study capacitation and to rank relative fertility of bulls. Previous binding assays were laborious, used 107 sperm per assay point, and required large amounts of radiolabeled heparin. A modified heparin-binding assay is described that used only 5 x 104 cells per incubation well and required reduced amounts of [3H] heparin. The assay was performed in 96-well Millititer plates, enabling easy incubation and filtering. Dissociation constants and concentrations of binding sites did not differ if analyzed by Scatchard plots, Woolf plots, or by log-logit transformed weighted nonlinear least squares regression, except in the case of outliers. In such cases, Scatchard analysis was more sensitive to outliers. Nonspecific binding was insignificant using nonlinear logistic fit regression and a proportion graph. The effects were tested of multiple free-thawing of sperm in either a commercial egg yolk extender, 40 mM Tris buffer with 8% glycerol, or 40 mM Tris buffer without glycerol. Freeze-thawing in extender did not affect the dissociation constant or the concentration of binding sites. However, freeze-thawing three times in 40 mM Tris reduced the concentration of binding sites and lowered the dissociation constant (raised the affinity). The inclusion of glycerol in the 40 mM Tris did not significantly affect the estimated dissociation constant or the concentration of binding sites as compared to 40 mM Tris without glycerol

  12. Allosteric indicator displacement enzyme assay for a cyanogenic glycoside.

    Science.gov (United States)

    Jose, D Amilan; Elstner, Martin; Schiller, Alexander

    2013-10-18

    Indicator displacement assays (IDAs) represent an elegant approach in supramolecular analytical chemistry. Herein, we report a chemical biosensor for the selective detection of the cyanogenic glycoside amygdalin in aqueous solution. The hybrid sensor consists of the enzyme β-glucosidase and a boronic acid appended viologen together with a fluorescent reporter dye. β-Glucosidase degrades the cyanogenic glycoside amygdalin into hydrogen cyanide, glucose, and benzaldehyde. Only the released cyanide binds at the allosteric site of the receptor (boronic acid) thereby inducing changes in the affinity of a formerly bound fluorescent indicator dye at the other side of the receptor. Thus, the sensing probe performs as allosteric indicator displacement assay (AIDA) for cyanide in water. Interference studies with inorganic anions and glucose revealed that cyanide is solely responsible for the change in the fluorescent signal. DFT calculations on a model compound revealed a 1:1 binding ratio of the boronic acid and cyanide ion. The fluorescent enzyme assay for β-glucosidase uses amygdalin as natural substrate and allows measuring Michaelis-Menten kinetics in microtiter plates. The allosteric indicator displacement assay (AIDA) probe can also be used to detect cyanide traces in commercial amygdalin samples. PMID:24123550

  13. Quantitative Microplate Assay for Real-Time Nuclease Kinetics

    OpenAIRE

    Eriksson, Jonas; Langel, Ülo

    2016-01-01

    Utilizing the phenomenon of nucleases exposing oligonucleotide phosphate backbones to phosphatases we present a novel quantitative method for kinetics of nuclease catalysis. Inorganic phosphate released from nuclease products by phosphatases could be quantified in real-time by a fluorescent sensor of inorganic phosphate. Two different nucleases were employed, showing the versatility of this assay for multiple turnover label-free nuclease studies.

  14. Development of a lion-specific interferon-gamma assay

    NARCIS (Netherlands)

    Maas, M.; Kooten, van P.J.S.; Schreuder, J.; Morar, D.; Tijhaar, E.; Michel, A.L.; Rutten, V.P.M.G.

    2012-01-01

    The ongoing spread of bovine tuberculosis (BTB) in African free-ranging lion populations, for example in the Kruger National Park, raises the need for diagnostic assays for BTB in lions. These, in addition, would be highly relevant for zoological gardens worldwide that want to determine the BTB stat

  15. A High-Throughput Yeast Halo Assay for Bioactive Compounds.

    Science.gov (United States)

    Bray, Walter; Lokey, R Scott

    2016-01-01

    When a disk of filter paper is impregnated with a cytotoxic or cytostatic drug and added to solid medium seeded with yeast, a visible clear zone forms around the disk whose size depends on the concentration and potency of the drug. This is the traditional "halo" assay and provides a convenient, if low-throughput, read-out of biological activity that has been the mainstay of antifungal and antibiotic testing for decades. Here, we describe a protocol for a high-throughput version of the halo assay, which uses an array of 384 pins to deliver ∼200 nL of stock solutions from compound plates onto single-well plates seeded with yeast. Using a plate reader in the absorbance mode, the resulting halos can be quantified and the data archived in the form of flat files that can be connected to compound databases with standard software. This assay has the convenience associated with the visual readout of the traditional halo assay but uses far less material and can be automated to screen thousands of compounds per day. PMID:27587777

  16. 40 CFR 79.64 - In vivo micronucleus assay.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) REGISTRATION OF FUELS AND FUEL ADDITIVES Testing Requirements for Registration § 79.64 In vivo... information on this test guideline, the following references should be consulted. (1) 40 CFR 798.5395, In Vivo... 40 Protection of Environment 16 2010-07-01 2010-07-01 false In vivo micronucleus assay....

  17. Tuberculosis Diagnosis: Assay Optimization, Validation, and Antigens for Specific Diagnosis

    Science.gov (United States)

    Interferon (IFN)-gamma release assays (i.e. Bovigam®, Prionics AG) are components of tuberculosis (TB) eradication programs in many countries. Because this test relies on functional leukocytes, environmental conditions before and during the in vitro culture period have the potential to influence the...

  18. New simple spectrophotometric assay of total carotenes in margarines

    NARCIS (Netherlands)

    Luterotti, S.; Bicanic, D.D.; Pozgaj, R.

    2006-01-01

    Direct and reliable spectrophotometric method for assaying total carotenes (TC) in margarines with the minimum of sample manipulation is proposed. For the first time saponification step used in determination of carotenes in margarines was omitted leading to a substantial cost saving and reduction of

  19. 21 CFR 864.7040 - Adenosine triphosphate release assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Adenosine triphosphate release assay. 864.7040 Section 864.7040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... disorders. (b) Classification. Class I (general controls)....

  20. Development of a VHH-Based Erythropoietin Quantification Assay

    DEFF Research Database (Denmark)

    Kol, Stefan; Beuchert Kallehauge, Thomas; Adema, Simon;

    2015-01-01

    Erythropoietin (EPO) quantification during cell line selection and bioreactor cultivation has traditionally been performed with ELISA or HPLC. As these techniques suffer from several drawbacks, we developed a novel EPO quantification assay. A camelid single-domain antibody fragment directed against...

  1. 21 CFR 866.3305 - Herpes simplex virus serological assays.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Herpes simplex virus serological assays. 866.3305 Section 866.3305 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... and mucous membranes to a severe form of encephalitis (inflammation of the brain). Neonatal...

  2. Interference of peptone and tyrosine with the lignin peroxidase assay.

    OpenAIRE

    ten Have, R.; Hartmans, S; Field, J. A.

    1997-01-01

    The N-unregulated white rot fungus Bjerkandera sp. strain BOS55 was cultured in 1 liter of peptone-yeast extract medium to produce lignin peroxidase (LiP). During the LiP assay, the oxidation of veratryl alcohol to veratraldehyde was inhibited due to tyrosine present in the peptone and the yeast extract.

  3. Bioanalytical method transfer considerations of chromatographic-based assays.

    Science.gov (United States)

    Williard, Clark V

    2016-07-01

    Bioanalysis is an important part of the modern drug development process. The business practice of outsourcing and transferring bioanalytical methods from laboratory to laboratory has increasingly become a crucial strategy for successful and efficient delivery of therapies to the market. This chapter discusses important considerations when transferring various types of chromatographic-based assays in today's pharmaceutical research and development environment. PMID:27277876

  4. IP-10 release assays in the diagnosis of tuberculosis infection

    DEFF Research Database (Denmark)

    Ruhwald, Morten; Aabye, Martine G; Ravn, Pernille

    2012-01-01

    The current state-of-the-art tests for infection with Mycobacterium tuberculosis - the IFN-γ release assays - rely on accurate measurement of the cytokine IFN-γ. Many other potential biomarkers are expressed in concert with IFN-γ, and IP-10 in particular has shown promising results. IP-10...

  5. A Sensitive Cyclic Nucleotide Phosphodiesterase Assay for Transient Enzyme Kinetics

    NARCIS (Netherlands)

    Lookeren Campagne, Michiel M. van; Haastert, Peter J.M. van

    1983-01-01

    A new assay for cyclic nucleotide phosphodiesterase has been developed by using reverse-phase column chromatography for the separation of product and substrate of the enzymatic reaction. The polar 5'-nucleotides are not retarded by the column, while the more lipophilic cyclic nucleotides bind to the

  6. Cytotoxicity assays to evaluate tannery effluents treated by photoelectrooxidation.

    Science.gov (United States)

    Jaeger, N; Moraes, J P; Klauck, C R; Gehlen, G; Rodrigues, M A S; Ziulkoski, A L

    2015-12-01

    The advanced oxidation process (AOP) is used to increase the treatment efficiency of effluents however, it is necessary to compare the toxicity of treated and untreated effluents to evaluate if the decontamination process does not cause any biological harm. Cultured cells have been previously used to assess the genotoxic and cytotoxic potential of various compounds. Hence, the aim of this work was to assess the applicability of cytotoxicity assays to evaluate the toxicity related to the AOP treatment. Samples of an industrial effluent were collected after their treatment by a conventional method. Cytotoxicity of standard and AOP treated effluents was assessed in CRIB and HEp-2 cell line using the MTT and neutral red assays. We observed decrease at cell viability in the both assays (50% MTT and 13% NRU) when cells were exposed to the AOP treatment in the highest concentration. Thus, cytotoxic assays in cultured cells can be explored as an useful method to evaluate toxicity as well as to optimize effluents treatment process. PMID:26628242

  7. DNA Y structure: a versatile, multidimensional single molecule assay.

    Science.gov (United States)

    Inman, James T; Smith, Benjamin Y; Hall, Michael A; Forties, Robert A; Jin, Jing; Sethna, James P; Wang, Michelle D

    2014-11-12

    Optical trapping is a powerful single molecule technique used to study dynamic biomolecular events, especially those involving DNA and DNA-binding proteins. Current implementations usually involve only one of stretching, unzipping, or twisting DNA along one dimension. To expand the capabilities of optical trapping for more complex measurements would require a multidimensional technique that combines all of these manipulations in a single experiment. Here, we report the development and utilization of such a novel optical trapping assay based on a three-branch DNA construct, termed a "Y structure". This multidimensional assay allows precise, real-time tracking of multiple configurational changes. When the Y structure template is unzipped under both force and torque, the force and extension of all three branches can be determined simultaneously. Moreover, the assay is readily compatible with fluorescence, as demonstrated by unzipping through a fluorescently labeled, paused transcription complex. This novel assay thus allows for the visualization and precision mapping of complex interactions of biomechanical events. PMID:25291441

  8. Possible errors in assay for beta-glycosidase activity.

    OpenAIRE

    Chadwick, R W; Allison, J C; Talley, D L; George, S.E.

    1995-01-01

    Cecal homogenates were assayed for the enzymes beta-glucosidase, beta-glucuronidase, and beta-galactosidase. Anaerobic incubation with the addition of excess 3,4-dichloronitrobenzene, a substrate for nitroreductase, significantly increased the detection of the beta-glycosidase enzymes' activities.

  9. Evaluation of environmental genotoxicity by comet assay in Columba livia.

    Science.gov (United States)

    González-Acevedo, Anahi; García-Salas, Juan A; Gosálvez, Jaime; Fernández, José Luis; Dávila-Rodríguez, Martha I; Cerda-Flores, Ricardo M; Méndez-López, Luis F; Cortés-Gutiérrez, Elva I

    2016-01-01

    The concentrations of recognized or suspected genotoxic and carcinogenic agents found in the air of large cities and, in particular, developing countries, have raised concerns about the potential for chronic health effects in the populations exposed to them. The biomonitoring of environmental genotoxicity requires the selection of representative organisms as "sentinels," as well as the development of suitable and sensitive assays, such as those aimed at assessing DNA damage. The aim of this study was to evaluate DNA damage levels in erythrocytes from Columba livia living in the metropolitan area of Monterrey, Mexico, compared with control animals via comet assay, and to confirm the results via Micronuclei test (MN) and DNA breakage detection-fluorescence in situ hybridization (DBD-FISH). Our results showed a significant increase in DNA migration in animals from the area assayed compared with that observed in control animals sampled in non-contaminated areas. These results were confirmed by MN test and DBD-FISH. In conclusion, these observations confirm that the examination of erythrocytes from Columba livia via alkaline comet assay provides a sensitive and reliable end point for the detection of environmental genotoxicants.

  10. Standard terminology of C26.10 nondestructive assay methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The terminology defined in this document is associated with nondestructive assay of nuclear material. 1.2 All of the definitions are associated with measurement techniques that measure nuclear emissions (that is, neutrons, gamma-rays, or heat) directly or indirectly. 1.3 definitions are relevant to any standards and guides written by subcommittee C26.10.

  11. 40 CFR 798.5460 - Rodent heritable translocation assays.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Rodent heritable translocation assays. 798.5460 Section 798.5460 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) HEALTH EFFECTS TESTING GUIDELINES Genetic Toxicity § 798.5460...

  12. 40 CFR 798.5450 - Rodent dominant lethal assay.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Rodent dominant lethal assay. 798.5450 Section 798.5450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) HEALTH EFFECTS TESTING GUIDELINES Genetic Toxicity § 798.5450 Rodent...

  13. Fluorescence assay for evaluating microbicidal activity of hand antiseptics.

    Science.gov (United States)

    Lopez-Gigosos, Rosa M; Mariscal, Alberto; Mariscal-Lopez, Eloisa; Gutierrez-Bedmar, Mario; Fernandez, Joaquin

    2015-11-01

    We developed a fluorescent β-d-glucuronidase activity (BGA)-based assay for detecting and quantifying Escherichia coli in samples to assess the biocide efficacy of hand antiseptics. The fluorescence level is proportional to the number of viable E. coli organisms present. We compared our assay results to those of the E. coli plate count method specified by the European standard for testing hygienic hand rub disinfectant products (EN1500). The plate count method requires excessive handling and materials and is not valid if the number of organisms per plate is too low or high for counting in many of the samples. We optimized the fluorescent assay based on the cleavage of 4-methylumbelliferyl-β-d-glucuronide by adding 4-nitrophenyl-β-d-glucuronide, a nonfluorogenic BGA substrate, to induce glucuronidase activity and reduce assay time. Furthermore, our method can be automated and eliminates the need for multiple dilutions. Fluorescence was temporally monitored, and the time required to reach a specific value of fluorescence was correlated with the initial number of viable E. coli organisms on the samples. There was a positive correlation (P counts by plate count and fluorescence methods. Reported effects in fluorescent BGA were compared to the EN1500 plate count method with five hand disinfectants. We found our method more advantageous, because it was as sensitive as the EN1500 method, requires less time to complete, and is less expensive and less laborious than conventional plating techniques.

  14. Comparison of Different Promoter Methylation Assays in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Karijn P. M. Suijkerbuijk

    2010-01-01

    Full Text Available Background: Promoter hypermethylation has emerged as a promising cancer biomarker. Currently, a large variety of quantitative and non-quantitative techniques is used to measure methylation in clinical specimens. Here we directly compared three commonly used methylation assays and assessed the influence of tissue fixation, target sequence location and the amount of DNA on their performance.

  15. Comparison of RIA, IRMA and LIA assays of serum ferritin

    International Nuclear Information System (INIS)

    The results of RIA, IRMA and LIA assays of ferritin in the human serum were compared. Various kits: IRMA FARMOS SPECTRIA (Finland), IRMA (CIS), the non-kit method RIA based on human placental ferritin prepared by the authors, and LIA-AMERLITE AMERSHAM (England) were evaluated and compared with RIA AMERSHAM (England). It was found that IRMA FARMOS SPECTRIA and the non-kit RIA assay based on placental ferritin give comparable and lower results in the whole range of the calibration curve (0-1000 μg/l) of RIA Amersham: 10-15% lower for the non-kit assay and 15-20% lower for the IRMA assay. The IRMA assay (CIS) gives comparable and higher results in the range up to 300 μg/l. The results for more concentrated solutions of ferritin with above 350 μg/l are low and unreliable. Correlation is not linear. Amerlite, a non-isotopic method, gives results comparable with the RIA method as far as accuracy and correctness is concerned. The range of the calibration curve is 0-2000 μg/l. The values of ferritin in serum are somewhat lower in the range up to 100 μg/l and the same values are somewhat higher in the range above 100 μg/l when comapred with the commercial RIA kit of Amersham. Altogether the values measured are within the range of statistical variance of values measured by the RIA Amersham method. (author) 4 tabs., 3 figs., 4 refs

  16. New lipase assay using Pomegranate oil coating in microtiter plates.

    Science.gov (United States)

    Ülker, Serdar; Placidi, Camille; Point, Vanessa; Gadenne, Benoît; Serveau-Avesque, Carole; Canaan, Stéphane; Carrière, Frédéric; Cavalier, Jean-François

    2016-01-01

    Lipases play various roles in fat digestion, lipoprotein metabolism, and in the mobilization of fat stored in lipid bodies in animals, plants and microorganisms. In association with these physiological functions, there is an important field of research for discovering lipase inhibitors and developing new treatments of diseases such as obesity, atherosclerosis, diabetes and tuberculosis. In this context, the development of convenient, specific and sensitive analytical methods for the detection and assay of lipases and/or lipase inhibitors is of major importance. It is shown here that purified triacylglycerols (TAGs) from Punica granatum (Pomegranate) seed oil coated on microtiter plates can be used for the continuous assay of lipase activity by recording the variations with time of the UV absorption spectra at 275 nm. UV absorption is due the release of punicic acid (9Z,11E,13Z-octadeca-9,11,13-trienoic acid), a conjugated triene contained in Pomegranate oil. This new microtiter plate assay allows to accurately measure the activity of a wider range of lipases compared to the similar assay previously developed with Tung oil containing α-eleostearic acid (9Z,11E,13E-octadeca-9,11,13-trienoic acid), including the LipY lipase from Mycobacterium tuberculosis. Although punicic acid is a diastereoisomer of α-eleostearic acid, the Δ(13)cis double bound found in punicic acid gives a different structure to the acyl chain that probably favours the interaction of Pomegranate TAGs with the lipase active site. The microplate lipase assay using Pomegranate TAGs shows high sensitivity, reproducibility and remarkable relevance for the high-speed screening of lipases and/or lipase inhibitors directly from raw culture media without any purification step. PMID:26343557

  17. ApoHRP-based Assay to Measure Intracellular Regulatory Heme

    Science.gov (United States)

    Atamna, Hani; Brahmbhatt, Marmik; Atamna, Wafa; Shanower, Gregory A.; Dhahbi, Joseph M.

    2015-01-01

    The majority of the heme-binding proteins possess a “heme-pocket” that stably binds with heme. Usually known as housekeeping heme-proteins, they participate in a variety of metabolic reactions (e.g., catalase). Heme also binds with lower affinity to the “Heme-Regulatory Motifs” (HRM) in specific regulatory proteins. This type of heme binding is known as exchangeable or regulatory heme (RH). Heme binding to HRM proteins regulates their function (e.g., Bach1). Although there are well-established methods for assaying total cellular heme (e.g., heme-proteins plus RH), currently there is no method available for measuring RH independently from the total heme (TH). The current study describes and validates a new method to measure intracellular RH. The method is based on the reconstitution of apo-horseradish peroxidase (apoHRP) with heme to form holoHRP. The resulting holoHRP activity is then measured with a colorimetric substrate. The results show that apoHRP specifically binds RH but not with heme from housekeeping heme-proteins. The RH assay detects intracellular RH. Furthermore, using conditions that create positive (hemin) or negative (N-methyl protoporphyrin IX) controls for heme in normal human fibroblasts (IMR90), the RH assay shows that RH is dynamic and independent from TH. We also demonstrated that short-term exposure to subcytotoxic concentrations of lead (Pb), mercury (Hg), or amyloid-β(Aβ) significantly alters intracellular RH with little effect on TH. In conclusion the RH assay is an effective assay to investigate intracellular RH concentration and demonstrates that RH represents ~6% of total heme in IMR90 cells. PMID:25525887

  18. Optimising automation of a manual enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    Corena de Beer

    2011-12-01

    Full Text Available Objective: Enzyme-linked immunosorbent assays (ELISAs are widely used to quantify immunoglobulin levels induced by infection or vaccination. Compared to conventional manual assays, automated ELISA systems offer more accurate and reproducible results, faster turnaround times and cost effectiveness due to the use of multianalyte reagents.Design: The VaccZyme™ Human Anti-Haemophilus influenzae type B (Hib kit (MK016 from The Binding Site Company was optimised to be used on an automated BioRad PhD™ system in the Immunology Laboratory (National Health Laboratory Service in Tygerberg, South Africa.Methods: An automated ELISA system that uses individual well incubation was compared to a manual method that uses whole-plate incubation.Results: Results were calculated from calibration curves constructed with each assay. Marked differences in calibration curves were observed for the two methods. The automated method produced lower-than-recommended optical density values and resulted in invalid calibration curves and diagnostic results. A comparison of the individual steps of the two methods showed a difference of 10 minutes per incubation cycle. All incubation steps of the automated method were subsequently increased from 30 minutes to 40 minutes. Several comparative assays were performed according to the amended protocol and all calibration curves obtained were valid. Calibrators and controls were also included as samples in different positions and orders on the plate and all results were valid.Conclusion: Proper validation is vital before converting manual ELISA assays to automated or semi-automated methods. 

  19. High Throughput SNP Genotyping with Two Mini-sequencing Assays

    Institute of Scientific and Technical Information of China (English)

    Chunqing LUO; Libin DENG; Changqing ZENG

    2004-01-01

    Two mini-sequencing methods,FP-TDI (template-directed dye-terminator incorporation with fluorescence-polarization) and MassArray (matrix assisted laser desorption ionization time of flight detection mass spectrometry),were optimized.A numeric standard was introduced to evaluate the SNP scoring quality of FP-TDI assay,thus made the optimization work easier.At the same time,using multi-PCR technology,8-plex genotyping of MassArray assay was successfully carried out,some softwares were developed and the data process of MassArray was highly automated.Then these two methods were applied to high throughput SNP genotyping,the accuracy,efficiency and robustness were compared.The result shows FP-TDI is more sensitive to the concentration of SNPprimer and PCR product,as well as extension cycles,the SNPprimer length of FP-TDI should be 24-30 bp long,whereas MassArray assay prefers to be as short as only 16 bp.Altogether 6440 SNP sites of human chromosome 3 were genotyped in a sample of 90 individuals,4792 sites by FP-TDI assay and 1648 sites by MassArray assay,the success rates of FP-TDI and MassArray were 67.7% and 93.6% respectively.The throughput of MassArray was higher than FP-TDI,and the cost of MassArray was lower,MassArray was more suitable for high throughput SNP genotyping.

  20. Comparison of genotoxicity of textile dyestuffs in Salmonella mutagenicity assay, in vitro micronucleus assay, and single cell gel/comet assay.

    Science.gov (United States)

    Wollin, Klaus-M; Gorlitz, Bernd-D

    2004-01-01

    The mutagenicity of textile dyes is an important consideration for the assurance of consumer protection and work safety. The mutagenicity testing of textile dyestuffs is crucial for accurately predicting health risks for consumers and workers exposed to dyes. Unfortunately, these data are often lacking. We studied the genotoxic activity of ten selected commercial textile dyestuffs, which are made up of mixtures of azo dyes and azo metal complex dyes as well as two anthraquinone dyestuffs. We used the Salmonella mutagenicity assay and cultured human keratinocytes (HaCaT cell line). In the S. typhimurium strain TA98, with and without S9, eight often dyestuffs investigated, and in strain TA 100, with and without S9, six often dyes caused frameshift mutations and base-pair substitutions in the dose range of 1-5000 microg/plate in a dose-related manner. All dyes, including those negative in the Salmonella mutagenicity assay, induced clastogenic effects in the in vitro micronucleus (MN) test in HaCaT cells as direct-acting mutagens in the concentration range of 5-150 microg/mL and with maximum MN frequencies between 1.1 and 7.2%, compared to negative controls that showed 0.2-0.4% MN cells. In the single cell gel/comet assay, all ten dyestuffs investigated caused DNA damage in HaCaT keratinocytes. The alkaline (pH >13) version used is capable of detecting DNA single strand breaks, alkali-labile sites, and DNA-DNA/DNA-protein cross-linking. Under the conditions of these screening tests, the textile dyes investigated are direct-acting genotoxic substances. The HaCaT cells testing protocol proposed has been shown to be an appropriate test system for evaluating mutagenicity of textile dyes on a base level.

  1. Evaluation of Presto(plus) assay and LightMix kit Trichomonas vaginalis assay for detection of Trichomonas vaginalis in dry vaginal swabs.

    Science.gov (United States)

    de Waaij, Dewi J; Ouburg, Sander; Dubbink, Jan Henk; Peters, Remco P H; Morré, Servaas A

    2016-08-01

    This is an evaluation study of the Presto(plus) Assay for T. vaginalis by comparing to the TIB MOLBIOL LightMix Kit Trichomonas vaginalis Assay using 615 dry collected vaginal and rectal swabs. Discordant samples were analyzed by the Qiagen® Microbial DNA qPCR for TV Assay. Both assays showed comparable performances (McNemar p>0.05). PMID:27268968

  2. Studying the genotoxicity of vincristine on human lymphocytes using comet assay, micronucleus assay and TCR gene mutation test in vitro

    International Nuclear Information System (INIS)

    The results of our previous investigation for workers occupationally exposed to vincristine (VCR) indicated that the genetic damage was detectable with comet assay, cytokinesis-block micronucleus (CBMN) assay and housekeeping gene mutation tests. In order to determine the results of above investigation and to inquire further the characteristics of genotoxicity of VCR, the cytogenetic effects of VCR on human lymphocytes were assessed with comet assay, CBMN assay and T-cell receptor (TCR) gene mutation test in vitro. The lymphocytes from two healthy donors were incubated for 24 h at doses of 0.00, 0.01, 0.02, 0.04, and 0.08 μg ml-1 VCR. The results of the present experiment showed that VCR not only could induce DNA damage, increase significantly micronucleus frequencies and the apoptotic cell ratios and decrease the nuclear division index (NDI) with dose-response relationship, but also could produce nucleoplasmic bridges (NPBs), a biomarker of DNA misrepair and/or telomere end-fusions and nuclear buds (NBUDs), a biomarker of elimination of amplified DNA and/or DNA repair complexes. Moreover, VCR could enhance TCR gene mutation frequency (Mf-TCR) of human lymphocytes. There was good correlation between the parameters (mean tail length, mean tail moment, micronucleus frequency, micronucleated frequency and Mf-TCR). The results of present study supported the results of our previous investigation for workers occupationally exposed to VCR, and the genotoxicity of VCR was determined at the different genetic end-points in vitro

  3. Comparative evaluation of two radioenzymatic procedures designed to determine noradrenaline in the plasma (COMT assay and PNMT assay)

    International Nuclear Information System (INIS)

    A comparative evaluation of two radioenzymatic procedures to determine the concentration of noradrenaline in the plasma - with linearity, sensitivity, specifity and accuracy serving as test criteria - led to the following results: In view of a probability of error in the order of 2% both methods were judged to show a satisfactory sensitivity. The specific of the COMT assay, by contrast with that of the PNMT assay, was found to be wanting, as the noradrenaline measurements in the presence of other biogenic amines were biassed in such a way that the values determined were higher than the actual concentrations. During antihypertensive treatment even minimal changes in the noradrenaline concentration can be ascertained on a quantitative basis. If suitable hardware is available, the COMT assay permits up to 25 single determinations to be carried out per day, while the number of double determinations is restricted to 7 per day. One advantage, however, lies in the fact that several catecholamines in the plasma can be detected simultaneously, if required. In cases where the noradrenaline concentration alone is to be determined for clinical purposes, preference should be given to the PNMT assay, as both tests showed equal linearity and sensitivity. (TRV)

  4. Energy Transfer Assays Using Quantum Dot-Gold Nanoparticle Complexes: Optimizing Oligonucleotide Assay Configuration Using Monovalently Conjugated Quantum Dots.

    Science.gov (United States)

    Uddayasankar, Uvaraj; Krull, Ulrich J

    2015-07-28

    The energy transfer between quantum dots (QDs) and gold nanoparticles (AuNPs) represents a popular transduction scheme in analytical assays that use nanomaterials. The impact of the spatial arrangement of the two types of nanoparticles on analytical performance has now been evaluated using a nucleic acid strand displacement assay. The first spatial arrangement (configuration 1) involved the assembly of a number of monovalently functionalized QD-oligonucleotide conjugates around a single central AuNP that was functionalized with complementary oligonucleotide sequences. The assembly of these complexes, and subsequent disassembly via target oligonucleotide-mediated displacement, were used to evaluate energy transfer efficiencies. Furthermore, the inner filter effect of AuNPs on the fluorescence intensity of the QD was studied. AuNPs of three different diameters (6, 13, and 30 nm) were used in these studies. Configuration 2 was based on the placement of monovalently functionalized AuNP-oligonucleotide conjugates around a single QD that was functionalized with a complementary oligonucleotide. The optimal assay configuration, established by evaluating energy transfer efficiencies and inner filter effects, was obtained by arranging at most 15 QDs around the 13 nm AuNP (configuration 1). These assays provided a 2.5-fold change in fluorescence intensity in the presence of target oligonucleotides. To obtain the same response with configuration 2 required the placement of three 6 nm AuNPs around the QD. This resulted in configuration 2 having a 5-fold lower fluorescence intensity when compared to configuration 1. The use of low-cost detection systems (digital camera) further emphasized the higher analytical performance of configuration 1. Response curves obtained using these detection systems demonstrated that configuration 1 had a 10-fold higher sensitivity when compared to configuration 2. This study provides an important framework for the development of sensitive assays

  5. The JaCVAM / OECD activities on the comet assay

    Directory of Open Access Journals (Sweden)

    Hajime Kojima

    2015-04-01

    Full Text Available The in vivo alkaline single cell gel electrophoresis assay, also called alkaline comet assay is a method measuring DNA strand breaks in eukaryotic cells. This assay was adopted in the Organisation for Economic Co-operation and Development (OECD Test guideline (TG 489 on September 26, 2014. This TG is part of a series of TGs on genetic toxicology. A formal validation trial of the this assay was performed in 2006-2012, coordinated by the Japanese Center for the Validation of Alternative Methods (JaCVAM, in conjunction with the European Union Reference Laboratory for alternatives to animal testing (EURL ECVAM, the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM and the NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM . The assay was reviewed by the OECD genotoxicity experts based on the JaCVAM trial (2014 and in Rothfuss et al. (2010. This TG includes the recommended use and limitations of the comet assay, and is based on the final protocol used in the validation trial, and on additional relevant published and unpublished (laboratories proprietary data. The outline of this TG describes below: each treated group is composed of a minimum of 5 animals of one sex (or of each sex as appropriate. A positive and a vehicle control group are also used. Administration of the treatment consists of daily doses over duration of 2 days or more, ensuring the test chemical reaches the target tissue which can be the liver, the kidney or other tissues if justified. Tissues of interest are dissected and single cells/nuclei suspensions are prepared and embedded in agarose on slides. Cells/nuclei are treated with lysis buffer to remove cellular and/or nuclear membranes. The nuclear DNA in the agar is then subjected to electrophoresis at high pH. This results in structures resembling comets which by using suitable fluorescent stain, can be observed by fluorescent microscopy. Based on their size

  6. Scrap Cans Assayed in 55-Gallon Drums by Adapted Q2 Technique

    Energy Technology Data Exchange (ETDEWEB)

    Salaymeh, S.R.

    2001-07-24

    This report describes an alternate assay technique developed to perform batch nondestructive assay (NDA) of ten scrap cans at a time. This report also discusses and compares the results of the one batch of ten scrap cans by assaying them individually at the 324-M assay station with the alternate assay technique developed to perform batch NDA of ten scrap cans at a time using the Q2.

  7. Trachoma rapid assessments in Unity and Northern Bahr-el-Ghazal States, Southern Sudan.

    Directory of Open Access Journals (Sweden)

    Emily Robinson

    Full Text Available BACKGROUND: Trachoma is thought to be endemic over large parts of Southern Sudan, but empirical evidence is limited. While some areas east of the Nile have been identified as highly endemic, few trachoma surveys have been conducted in the remainder of the country. This study aimed to determine whether trachoma constitutes a problem to public health in Northern Bahr-el-Ghazal and Unity State, both located west of the Nile. METHODS AND PRINCIPAL FINDINGS: Trachoma rapid assessments (TRA were conducted between July and September 2009. Seven villages in Northern Bahr-el-Ghazal State and 13 villages in Unity State were surveyed; an average of 50 children (age 1-9 years and 44 women (age 15 years and above were examined per village. Samples for analysis using the APTIMA Combo-2 nucleic acid amplification test (NAAT were collected from participants with active trachoma in eight villages in Unity State. In Northern Bahr-el-Ghazal State, only three children with active trachoma (trachomatous inflammation follicular (TF and/or trachomatous inflammation intense (TI and two women with trichiasis (TT were found, in two of the seven villages surveyed. In Unity State, trachoma was endemic in all thirteen villages surveyed; the proportion of children with active trachoma ranged from 33% to 75% between villages, while TF in children ranged from 16% to 44%. Between 4% to 51% of examined women showed signs of TT. Samples from active trachoma cases tested using the NAAT were positive for Chlamydia trachomatis infection for 46.6% of children and 19.0% of women. CONCLUSIONS: Trachoma presents a major problem to public health Unity State, while the disease is of low priority in Northern-Bahr-el-Ghazal State. Implementation of a population-based prevalence survey is now required in Unity State to generate baseline prevalence data so that trachoma interventions can be initiated and monitored over time.

  8. A modified method for the turbidimetric assay of nisin

    Directory of Open Access Journals (Sweden)

    Simone Hickmann Flôres

    2003-06-01

    Full Text Available Nisin is an antibacterial peptide produced by Lactococcus lactis subsp. lactis that shows a broad spectrum of inhibitory activity against gram-positive microorganism including bacterial spores. Methods for nisin activity estimation in solution is redefined. In this work a new turbidimetric assay method has been described making possible to assay nisin satisfactorily in total incubation period of approximately six hours.Nisina é um peptídeo antibacteriano produzido por Lactococcus lactis subsp lactis que apresenta um grande espectro antimicrobiano para microrganismos gram-positivos incluindo esporos bacterianos. Alguns métodos para deteminação da atividade de nisina foram definidos. Neste trabalho foi proposto uma modificação no método para determinação de nisina no qual obteve-se resultados satisfatórios em aproximadamente 6 horas.

  9. Design and Implementation of High-Throughput Screening Assays.

    Science.gov (United States)

    Powell, David J; Hertzberg, Robert P; Macarrόn, Ricardo

    2016-01-01

    HTS remains at the core of the drug discovery process, and so it is critical to design and implement HTS assays in a comprehensive fashion involving scientists from the disciplines of biology, chemistry, engineering, and informatics. This requires careful consideration of many options and variables, starting with the choice of screening strategy and ending with the discovery of lead compounds. At every step in this process, there are decisions to be made that can greatly impact the outcome of the HTS effort, to the point of making it a success or a failure. Although specific guidelines should be established to ensure that the screening assay reaches an acceptable level of quality, many choices require pragmatism and the ability to compromise opposing forces. PMID:27316985

  10. Real‑time, fast neutron detection for stimulated safeguards assay

    International Nuclear Information System (INIS)

    The advent of low‑hazard organic liquid scintillation detectors and real‑time pulse‑shape discrimination (PSD) processing has suggested a variety of modalities by which fast neutrons, as opposed to neutrons moderated prior to detection, can be used directly to benefit safeguards needs. In this paper we describe a development of a fast‑neutron based safeguards assay system designed for the assessment of 235U content in fresh fuel. The system benefits from real‑time pulse‑shape discrimination processing and auto‑calibration of the detector system parameters to ensure a rapid and effective set‑up protocol. These requirements are essential in optimising the speed and limit of detection of the fast neutron technique, whilst minimising the intervention needed to perform the assay.

  11. Characterization of Leptospiral Chemoreceptors Using a Microscopic Agar Drop Assay.

    Science.gov (United States)

    Affroze, Samia; Islam, Md Shafiqul; Takabe, Kyosuke; Kudo, Seishi; Nakamura, Shuichi

    2016-08-01

    Bacterial chemotaxis is induced by sensing chemical stimuli via chemoreceptors embedded in the cytoplasmic membrane, enabling the cells to migrate toward nutrients or away from toxins. The chemoreceptors of Escherichia coli and Salmonella spp. have been well studied and are functionally classified on the basis of detectable substrates. The spirochete Leptospira possesses more than ten chemoreceptors and shows attractive or repellent responses against some sugars, amino acids, and fatty acids. However, the roles of these chemoreceptors have not been investigated. In this study, we conducted a chemotaxis assay called microscopic agar drop assay in combination with competition experiments, determining whether two kinds of attractants are recognized by the same type of chemoreceptor in the saprophytic Leptospira strain, Leptospira biflexa. Analyzing the competition effect observed between several pairs of chemicals, we found that L. biflexa senses sugars via chemoreceptors different from those that sense amino acids and fatty acids.

  12. Peroxynitrite scavenging by different antioxidants. Part I: convenient assay.

    Science.gov (United States)

    Balavoine, G G; Geletii, Y V

    1999-01-01

    A convenient "tube" assay to quantify relative antioxidant activities in aqueous solutions has been developed. Peroxynitrite was employed as a biologically relevant source of radicals with Pyrogallol Red as a detecting molecule. A variety of compounds have been examined, namely polyphenols, uric acid, glutathione, and ascorbic acid. Competition kinetics were observed for the majority of examined compounds, except thymol and ascorbic acid. Pyrogallol Red was fully protected by ascorbic acid against the bleaching by peroxynitrite until its total consumption. The deviation from competition kinetics in the case of thymol was due to the formation of radicals from thymol and their subsequent reaction with Pyrogallol Red. Quercetin was the most efficient scavenger of free radicals. The measurements of relative antioxidant activities using Pyrogallol Red and other detecting molecules, such as gallocyanine and carminic acid, were in fair agreement. The assay was successfully used for a screening of antioxidant activity of plant extracts of unknown composition. PMID:10355895

  13. DNA Damage among Wood Workers Assessed with the Comet Assay

    Science.gov (United States)

    Bruschweiler, Evin Danisman; Wild, Pascal; Huynh, Cong Khanh; Savova-Bianchi, Dessislava; Danuser, Brigitta; Hopf, Nancy B.

    2016-01-01

    Exposure to wood dust, a human carcinogen, is common in wood-related industries, and millions of workers are occupationally exposed to wood dust worldwide. The comet assay is a rapid, simple, and sensitive method for determining DNA damage. The objective of this study was to investigate the DNA damage associated with occupational exposure to wood dust using the comet assay (peripheral blood samples) among nonsmoking wood workers (n = 31, furniture and construction workers) and controls (n = 19). DNA damage was greater in the group exposed to composite wood products compared to the group exposed to natural woods and controls (P < 0.001). No difference in DNA damage was observed between workers exposed to natural woods and controls (P = 0.13). Duration of exposure and current dust concentrations had no effect on DNA damage. In future studies, workers’ exposures should include cumulative dust concentrations and exposures originating from the binders used in composite wood products. PMID:27398027

  14. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  15. A spectrophotometric assay for the detection of fungal peroxygenases.

    Science.gov (United States)

    Poraj-Kobielska, Marzena; Kinne, Matthias; Ullrich, René; Scheibner, Katrin; Hofrichter, Martin

    2012-02-01

    Rapid and simple spectrophotometric methods are required for the unambiguous detection of recently discovered fungal peroxygenases in vivo and in vitro. This paper describes a peroxygenase-specific assay using 5-nitro-1,3-benzodioxole as substrate. The product, 4-nitrocatechol, produces a yellow color at pH 7, which can be followed over time at 425 nm (ε(425)=9,700 M(-1) cm(-1)), and a red color when adjusted to pH >12, which can be measured in form of an end-point determination at 514 nm (ε(514)=11,400 M(-1) cm(-1)). The assay is suitable for detecting peroxygenase activities in complex growth media and environmental samples as well as for high-throughput screenings.

  16. Microwave-mediated enzyme-linked immunosorbent assay procedure.

    Science.gov (United States)

    Nahar, Pradip; Bora, Utpal; Sharma, Gainda L; Kannoujia, Dileep Kumar

    2012-02-15

    Here we demonstrate a novel microwave-mediated enzyme-linked immunosorbent assay (MELISA) method that has dramatically reduced the enzyme-linked immunosorbent assay (ELISA) timing to less than 5 min with a result comparable to that obtained by 18-h conventional ELISA. Efficacy of the MELISA procedure is demonstrated by detecting human immunoglobulin G (IgG), rabbit IgG, human immunoglobulin E (IgE), human interleuken 1β (IL-1β), Entamoeba histolytica antibody, and Aspergillus fumigatus antibody. MELISA could be an excellent substitute for time-consuming conventional ELISA for rapid diagnosis of diseases in cases of medical urgency, outbreak of infectious diseases, and screening of samples in blood banks or emigration counters. PMID:22033289

  17. Synthesis and reducing power assay of methyl semicarbazone derivatives

    Directory of Open Access Journals (Sweden)

    Manmohan Singhal

    2014-04-01

    Full Text Available In the present study we have designed a new pharmacophore ‘Chalconesemicarbazone’ by pharmacophore hybridization approach of drug design. A series of novel chalconesemicarbazones was synthesized and evaluated for their antioxidant activity by reducing power assay. Most of the compounds were found to be potent antioxidants. Free radicals play an important role in various pathological and xenotoxic effects so antioxidant may have protective role in these pathological conditions. Based on the results of reducing power assay 1-[1-(2,4-dihydroxyphenyl-3-(2-hydroxyphenylallylidene]-4-(4-methylphenylsemicarbazide (compound 18 and 1-[1-(2,5-dihydroxyphenyl-3-(6-hydroxyphenylallylidene]-4-(4-methylphenylsemicarbazide (compound 21 were the most active lead compounds. It was found that methoxy and hydroxyl substituted chalconesemicarbazones exhibited potent reducing power and unsubstituted compound showed less reducing potential.

  18. Toxin activity assays, devices, methods and systems therefor

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan; Schaff, Ulrich Y.; Sommer, Gregory Jon

    2016-04-05

    Embodiments of the present invention are directed toward devices, system and method for conducting toxin activity assay using sedimentation. The toxin activity assay may include generating complexes which bind to a plurality of beads in a fluid sample. The complexes may include a target toxin and a labeling agent, or may be generated due to presence of active target toxin and/or labeling agent designed to be incorporated into complexes responsive to the presence of target active toxin. The plurality of beads including the complexes may be transported through a density media, wherein the density media has a lower density than a density of the beads and higher than a density of the fluid sample, and wherein the transporting occurs, at least in part, by sedimentation. Signal may be detected from the labeling agents of the complexes.

  19. Immunoradiometric assay for carcinoembryonic antigenusing avidin-biotin separation technique

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    A sensitive, specific, noncompetitive, sandwich-typeradioimmunoassay for carcinoembryonic antigen (CEA) has been developedin our laboratory, which can be performedconveniently. The assay involves two monoclonal antibodies, selected for highaffinity and specificity and also for reaction against antigenic sites on CEA that aredistal from each other. One of these antibodies was labeled with125I and the other wasconjugated covalently to biotin. Polystyrene tubes were conjugated covalently toavidin. These tubes represent a rapid, simple method for separating the CEA-boundantibody from the free antibody. The biotin-antibody-CEA-125I-labeled antibodycomplexes bind to the tubes and CEA concentration is directly related to counts perminute. This assay can detect the CEA at a concentration of 0.22 μg/L in serum.

  20. Computed neutron coincidence counting applied to passive waste assay

    International Nuclear Information System (INIS)

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs

  1. Automated 5 ' nuclease PCR assay for identification of Salmonella enterica

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Ahrens, Peter; Rådström, P.

    2000-01-01

    A simple and ready-to-go test based on a 5' nuclease (TaqMan) PCR technique was developed for identification of presumptive Salmonella enterica isolates. The results were compared with those of conventional methods. The TaqMan assay was evaluated for its ability to accurately detect 210 S. enterica...... isolates, including 100 problematic "rough" isolates. An internal positive control was designed to use the same Salmonella primers for amplification of a spiked nonrelevant template (116 bp) in the sample tube. The PCR test correctly identified all the Salmonella strains by resulting in positive end...... Salmonella strains tested resulted in positive FAM and TET signals. In addition, it was found that the complete PCR mixture, predispensed in microwell plates, could be stored for up to 3 months at -20 degrees C, Thus, the diagnostic TaqMan assay developed can be a useful and simple alternative method...

  2. Microplate receptor assays: tools for monitoring seafood toxins

    International Nuclear Information System (INIS)

    Global increase in toxic algal blooms and the resultant increase in the incidence of human illness, many seafood monitoring program have been established worldwide to determine the presence of algal toxins, and one of the standard method of detection for algal toxins is the mouse bioassay. Receptor assay are appropriate for those toxin classes that interact with membrane receptors including the voltage dependent sodium channel and the glutamate receptor and most of algal toxins in seafood occur that possess different toxic potencies and are present in contaminated seafood. Receptor assays are particularly applicable for measuring total toxic potency since, within a toxin class, all congeners bind to the same receptor and relative binding affinities correlate well with their relative toxic potencies

  3. Allergenicity assay of allergen from Dermatophagoides farinae in transgenic tobacco

    Institute of Scientific and Technical Information of China (English)

    TANG Mingjuan; SHEN Ye; HU Yuanlei; CAO Lei; NI Ting; ZHANG Hongyu; LIN Zhongping

    2004-01-01

    Derf2 gene for one of mite allergens in Dermatophagoides farinae has been cloned and expressed under regulation of 35S promoter in transgenic tobacco. The transcriptional analysis showed that this mite complete gene structure in genomic sequence could be spliced at prediction site. Allergenicity assay with immunological sera indicated that the extracts from the transgenic tobacco gave obvious positive IgE binding reaction with specific serum pool. This work would be of potential use in allergenicity assessment of genetically modified food.

  4. ASSAY FOR RAPID SCREENING OF PHYTOCHEMICALS AS ANTIMICROBIAL AGENTS

    OpenAIRE

    Ghosh Saurav; Indranil Mukherjee; Ashoke Ranjan Thakur; Shaon Ray Chaudhuri

    2013-01-01

    The present study aims to develop a rapid method for antibiotic sensitivity detection and screening of natural products for antimicrobial activity. The dimension of WBC in blood film was found to get altered when seeded with bacteria and monitored under light microscope. The shrinkage was prevented in response to antibiotic treatment and validated using statistical analysis (two sample one tailed Z test). Thus here is a prompt (4 h) assay system for detection of blood infection, antibiotic se...

  5. ASSESSMENT OF TOXICITY OF INDUSTRIAL WASTES USING CROP PLANT ASSAYS

    OpenAIRE

    Carmen Alice Teacă; Ruxanda Bodîrlău

    2008-01-01

    Environmental pollution has a harmful action on bioresources, including agricultural crops. It is generated through many industrial activities such as mining, coal burning, chemical technology, cement production, pulp and paper industry, etc. The toxicity of different industrial wastes and heavy metals excess was evaluated using crop plant assays (germination and hydroponics seedlings growth tests). Experimental data regarding the germination process of wheat (from two cultivars) and rye seed...

  6. Bovine Papillomavirus Clastogenic Effect Analyzed in Comet Assay

    OpenAIRE

    Araldi, R. P.; Melo, T. C.; N. Diniz; J. Mazzuchelli-de-Souza; R.F. Carvalho; Beçak, W.; Stocco, R. C.

    2013-01-01

    Bovine papillomavirus (BPV) is an oncogenic virus related to serious livestock diseases. Oncoproteins encoded by BPV are involved in several steps of cellular transformation and have been reported as presenting clastogenic effects in peripheral lymphocytes and primary culture cells. The aim of this study was to evaluate the clastogenic potential of BPV types 1, 2, and 4 by comet assay. Peripheral blood was collected from 37 bovines, 32 infected with different levels of papillomatosis (12 anim...

  7. Teratoma: from spontaneous tumors to the pluripotency/malignancy assay.

    Science.gov (United States)

    Bulic-Jakus, Floriana; Katusic Bojanac, Ana; Juric-Lekic, Gordana; Vlahovic, Maja; Sincic, Nino

    2016-01-01

    A teratoma is a benign tumor containing a mixture of differentiated tissues and organotypic derivatives of the three germ layers, while a teratocarcinoma also contains embryonal carcinoma cells (EC cells). Experimental teratomas and teratocarcinomas have been derived from early mammalian embryos transplanted into the adult animal (ectopic sites). In the rat, the pluripotency of the transplanted epiblast was demonstrated and a quantifiable restriction of developmental potential persisted after subsequent transplantation of chemically defined cultivated postimplantation embryos. The rat is nonpermissive for teratocarcinoma development and rat pluripotent cell lines have been established only recently. Transplantation of mouse embryos, epiblast, or embryonic stem cells (mESCs) gave rise to teratocarcinomas. The pluripotency of reprogrammed human cells has been tested by a 'gold standard' trilaminar teratoma assay in immunocompromised mice in vivo. Human pluripotent stem cells proposed for use in regenerative medicine such as human embryonic stem cell (hESC), human nuclear-transfer/therapeutic cloning embryonic stem cell (NT-ESC), or human induced pluripotent stem cell (hiPSC) lines, once differentiated in vitro to the desired cell type, should be again tested in a long-term animal teratoma assay to exclude their malignancy. Such an approach led to a recently implemented human therapy with retinal pigmented epithelium. For greater biosafety, the teratoma assay should be standardized and complemented by assessments of mutations/epimutations, RNA/protein expression, and possible immunogenicity of autologous pluripotent cells. Furthermore, the standardized teratoma assay should be directed more to the assessment of EC/malignant cell features than of differentiated tissues, especially after a unique case of human therapy with neural stem cells was found to lead to malignancy. For further resources related to this article, please visit the WIREs website. PMID:26698368

  8. Automated saccharification assay for determination of digestibility in plant materials

    Directory of Open Access Journals (Sweden)

    Halpin Claire

    2010-10-01

    Full Text Available Abstract Background Cell wall resistance represents the main barrier for the production of second generation biofuels. The deconstruction of lignocellulose can provide sugars for the production of fuels or other industrial products through fermentation. Understanding the biochemical basis of the recalcitrance of cell walls to digestion will allow development of more effective and cost efficient ways to produce sugars from biomass. One approach is to identify plant genes that play a role in biomass recalcitrance, using association genetics. Such an approach requires a robust and reliable high throughput (HT assay for biomass digestibility, which can be used to screen the large numbers of samples involved in such studies. Results We developed a HT saccharification assay based on a robotic platform that can carry out in a 96-well plate format the enzymatic digestion and quantification of the released sugars. The handling of the biomass powder for weighing and formatting into 96 wells is performed by a robotic station, where the plant material is ground, delivered to the desired well in the plates and weighed with a precision of 0.1 mg. Once the plates are loaded, an automated liquid handling platform delivers an optional mild pretreatment ( Conclusions The automated assay systems are sensitive, robust and reliable. The system can reliably detect differences in the saccharification of plant tissues, and is able to process large number of samples with a minimum amount of human intervention. The automated system uncovered significant increases in the digestibility of certain lignin modified lines in a manner compatible with known effects of lignin modification on cell wall properties. We conclude that this automated assay platform is of sufficient sensitivity and reliability to undertake the screening of the large populations of plants necessary for mutant identification and genetic association studies.

  9. A Continuous Kinetic Assay for Adenylation Enzyme Activity and Inhibition

    OpenAIRE

    Daniel J. Wilson; Aldrich, Courtney C.

    2010-01-01

    Adenylation/adenylate-forming enzymes catalyze the activation of a carboxylic acid at the expense of ATP to form an acyl-adenylate intermediate and pyrophosphate (PPi). In a second half-reaction, adenylation enzymes catalyze the transfer of the acyl moiety of the acyl-adenylate onto an acceptor molecule, which can be either a protein or a small molecule. We describe the design, development, and validation of a coupled continuous spectrophotometric assay for adenylation enzymes that employs hy...

  10. Solid waste transuranic storage and assay facility indoor air sampling

    Energy Technology Data Exchange (ETDEWEB)

    Pingel, L.A., Westinghouse Hanford

    1996-08-20

    The purpose of the study is to collect and analyze samples of the indoor air at the Transuranic Storage and Assay Facility (TRUSAF), Westinghouse Hanford. A modified US EPA TO-14 methodology, using gas chromatography/mass spectrography, may be used for the collection and analysis of the samples. The information obtained will be used to estimate the total release of volatile organic compounds from TRUSAF to determine the need for air emmission permits.

  11. Non-destructive assay for uranium standard sample

    International Nuclear Information System (INIS)

    A series of uranium standard samples used for active coincidence non-destructive assay were tested by using active well coincidence counter equipment and JSR-12 coincidence counter. The tested uranium standard samples are consists of 24 pieces of 20 g sample, 4 pieces of 40 g sample and 4 pieces of 80 g sample. The results show that the combined relative standard uncertainty is about 2% for 20 g, 40 g samples and less than 2% for 80 g sample. (authors)

  12. Cell Migration and Invasion Assays as Tools for Drug Discovery

    OpenAIRE

    Hulkower, Keren I.; Herber, Renee L.

    2011-01-01

    Cell migration and invasion are processes that offer rich targets for intervention in key physiologic and pathologic phenomena such as wound healing and cancer metastasis. With the advent of high-throughput and high content imaging systems, there has been a movement towards the use of physiologically relevant cell-based assays earlier in the testing paradigm. This allows more effective identification of lead compounds and recognition of undesirable effects sooner in the drug discovery screeni...

  13. Detection of Shiga Toxins by Lateral Flow Assay

    OpenAIRE

    Ching, Kathryn H; Xiaohua He; Stanker, Larry H.; Lin, Alice V.; Jeffery A. McGarvey; Robert Hnasko

    2015-01-01

    Shiga toxin-producing Escherichia coli (STEC) produce shiga toxins (Stxs) that can cause human disease and death. The contamination of food products with STEC represents a food safety problem that necessitates rapid and effective detection strategies to mitigate risk. In this manuscript, we report the development of a colorimetric lateral flow assay (LFA) for the rapid detection of Stxs in <10 min using a pair of monoclonal antibodies that bind epitopes common to Stx1 and six Stx2 variants...

  14. Repurposing CRISPR/Cas9 for in situ functional assays

    OpenAIRE

    Malina, Abba; Mills, John R.; Cencic, Regina; YAN, YIFEI; Fraser, James; Schippers, Laura M.; Paquet, Marilène; Dostie, Josée; Pelletier, Jerry

    2013-01-01

    Malina et al. readapted the CRISPR/Cas9 genome-editing system for targeted gene disruption positive selection assays. They generated “all-in-one” lentiviral and retroviral delivery vectors heterologously expressing both a codon-optimized Cas9 and its synthetic guide RNA (sgRNA) and linked Cas9 expression to GFP fluorescence for in vivo applications. These results establish Cas9 genome editing as a powerful and practical approach for positive in situ genetic screens.

  15. A Multiplex Assay for Detection of Staphylococcal and Streptococcal Exotoxins.

    Directory of Open Access Journals (Sweden)

    Preeti Sharma

    Full Text Available Staphylococcal and streptococcal exotoxins, also known as superantigens, mediate a range of diseases including toxic shock syndrome, and they exacerbate skin, pulmonary and systemic infections caused by these organisms. When present in food sources they can cause enteric effects commonly known as food poisoning. A rapid, sensitive assay for the toxins would enable testing of clinical samples and improve surveillance of food sources. Here we developed a bead-based, two-color flow cytometry assay using single protein domains of the beta chain of T cell receptors engineered for high-affinity for staphylococcal (SEA, SEB and TSST-1 and streptococcal (SpeA and SpeC toxins. Site-directed biotinylated forms of these high-affinity agents were used together with commercial, polyclonal, anti-toxin reagents to enable specific and sensitive detection with SD50 values of 400 pg/ml (SEA, 3 pg/ml (SEB, 25 pg/ml (TSST-1, 6 ng/ml (SpeA, and 100 pg/ml (SpeC. These sensitivities were in the range of 4- to 80-fold higher than achieved with standard ELISAs using the same reagents. A multiplex format of the assay showed reduced sensitivity due to higher noise associated with the use of multiple polyclonal agents, but the sensitivities were still well within the range necessary for detection in food sources or for rapid detection of toxins in culture supernatants. For example, the assay specifically detected toxins in supernatants derived from cultures of Staphylococcus aureus. Thus, these reagents can be used for simultaneous detection of the toxins in food sources or culture supernatants of potential pathogenic strains of Staphylococcus aureus and Streptococcus pyogenes.

  16. Multisite Analytical Evaluation of the Abbott ARCHITECT Cyclosporine Assay.

    OpenAIRE

    Wallemacq, Pierre; Maine, Gregory,; Berg, Keith; Rosiere, Thomas; Marquet, Pierre; Aimo, Giuseppe; Mengozzi, Giulio; Young, Juliana; Wonigert, Kurt; Krestchmer, Robert; Wermuth, Bendicht; Schmid, Rainer,

    2010-01-01

    International audience The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT assay uses a whole blood specimen, a pretreatment step with organic reagents to precipitate proteins and extract the drug, followed by a 2-step automated i...

  17. Mining Chemical Activity Status from High-Throughput Screening Assays

    KAUST Repository

    Soufan, Othman

    2015-12-14

    High-throughput screening (HTS) experiments provide a valuable resource that reports biological activity of numerous chemical compounds relative to their molecular targets. Building computational models that accurately predict such activity status (active vs. inactive) in specific assays is a challenging task given the large volume of data and frequently small proportion of active compounds relative to the inactive ones. We developed a method, DRAMOTE, to predict activity status of chemical compounds in HTP activity assays. For a class of HTP assays, our method achieves considerably better results than the current state-of-the-art-solutions. We achieved this by modification of a minority oversampling technique. To demonstrate that DRAMOTE is performing better than the other methods, we performed a comprehensive comparison analysis with several other methods and evaluated them on data from 11 PubChem assays through 1,350 experiments that involved approximately 500,000 interactions between chemicals and their target proteins. As an example of potential use, we applied DRAMOTE to develop robust models for predicting FDA approved drugs that have high probability to interact with the thyroid stimulating hormone receptor (TSHR) in humans. Our findings are further partially and indirectly supported by 3D docking results and literature information. The results based on approximately 500,000 interactions suggest that DRAMOTE has performed the best and that it can be used for developing robust virtual screening models. The datasets and implementation of all solutions are available as a MATLAB toolbox online at www.cbrc.kaust.edu.sa/dramote and can be found on Figshare.

  18. The Use of Chemical Reactivity Assays in Toxicity Prediction

    OpenAIRE

    ASTURIOL David; Worth, Andrew

    2011-01-01

    The use of so-called “in chemico” methodology - abiotic assays that measure chemical reactivity - is gaining ground as relevant and reliable means of toxicity prediction. In this report we explain the basis of the in chemico approach to toxicity prediction and we review the studies that have developed the concept and its practical application since the 1930s, with special attention being paid to studies aimed at the development of Quantitative Structure-Activity Relationship (QSAR) models and...

  19. Methodology for statistical analysis of SENCAR mouse skin assay data.

    OpenAIRE

    Stober, J A

    1986-01-01

    Various response measures and statistical methods appropriate for the analysis of data collected in the SENCAR mouse skin assay are examined. The characteristics of the tumor response data do not readily lend themselves to the classical methods for hypothesis testing. The advantages and limitations of conventional methods of analysis and methods recommended in the literature are discussed. Several alternative response measures that were developed specifically to answer the problems inherent i...

  20. A greenhouse screening assay for Botrytis tulipae resistance in tulips

    OpenAIRE

    Straathof, T.P.; Mes, J.J.; Eikelboom, W; Tuyl, van, J.M.

    2002-01-01

    As a leaf pathogen, Botrytis tulipae severely affects tulip bulb production. Chemical control is not desired for environmental reasons. Thus, resistant cultivars can play an important role in the control of this disease. To select genotypes resistant to B. tulipae, a reliable screening assay is needed. A greenhouse test was developed to establish resistance at clonal level. Removal of the wax layer by soft rubbing of the leaves was essential to obtain a homogeneous distribution of the spore s...

  1. Nondestructive assay technology and automated ''real-time'' materials control

    International Nuclear Information System (INIS)

    Significant advances in nondestructive assay techniques and instrumentation now enable rapid, accurate and direct in-plant measurement of nuclear material on a continuous or ''real-time'' basis as it progresses through a nuclear facility. A variety of passive and active assay instruments are required for the broad range of materials measurement problems encountered by safeguards inspectors and facility operators in various types of nuclear plants. Representative NDA techniques and instruments are presented and reviewed with special attention to their assay capabilities and areas of applicability in the nuclear fuel cycle. An advanced system of materials control - called ''DYMAC'', for Dynamic Materials Control - is presently under development by the U.S. Energy Research and Development Administration; the DYMAC program integrates new nondestructive assay instrumentation and modern data-processing methods, with the overall objective of demonstrating a workable, cost-effective system of stringent safeguards and materials control in various generic types of facilities found in the nuclear fuel cycle. Throughout the program, emphasis will be placed on devloping practical solutions to generic measurement problems so that resulting techniques and instrumentation will have widespread utility. Projected levels of safeguards assurance, together with other vital - and cost-sensitive - plant operational factors such as process and quality control, criticality safety and waste management are examined in an evaluation of the impact of future advanced materials control systems on overall plant operations, efficiency and productivity. The task of implementing effective and stringent safeguards includes the transfer of new safeguards technology to the nuclear industry. Clearly the training of inspectors (both IAEA and national), plant people, etc., in the effective use of new NDA equipment is of paramount importance; thus in the United States, the Energy Research and Development

  2. CFAssay: statistical analysis of the colony formation assay

    OpenAIRE

    Braselmann, Herbert; Michna, Agata; Heß, Julia; Unger, Kristian

    2015-01-01

    Background Colony formation assay is the gold standard to determine cell reproductive death after treatment with ionizing radiation, applied for different cell lines or in combination with other treatment modalities. Associated linear-quadratic cell survival curves can be calculated with different methods. For easy code exchange and methodological standardisation among collaborating laboratories a software package CFAssay for R (R Core Team, R: A Language and Environment for Statistical Compu...

  3. Pseudotype-based neutralization assays for influenza: a systematic analysis

    Directory of Open Access Journals (Sweden)

    George William Carnell

    2015-04-01

    Full Text Available The use of vaccination against the influenza virus remains the most effective method of mitigating the significant morbidity and mortality caused by this virus. Antibodies elicited by currently licensed influenza vaccines are predominantly hemagglutination-inhibition (HI-competent antibodies that target the globular head of HA thus inhibiting influenza virus entry into target cells. These antibodies predominantly confer homosubtypic/strain specific protection and only rarely confer heterosubtypic protection. However, recent academia or pharma-led R&D towards the production of a universal vaccine has centered on the elicitation of antibodies directed against the stalk of the influenza HA that has been shown to confer broad protection across a range of different subtypes (H1 to H16. The accurate and sensitive measurement of antibody responses elicited by these next-generation influenza vaccines is however hampered by the lack of sensitivity of the traditional influenza serological assays hemagglutinin inhibition (HI, single radial hemolysis (SRH and microneutralization (MN. Assays utilizing pseudotypes, chimeric viruses bearing influenza glycoproteins, have been shown to be highly efficient for the measurement of homosubtypic and heterosubtypic broadly-neutralizing antibodies, making them ideal serological tools for the study of cross-protective responses against multiple influenza subtypes with pandemic potential. In this review, we will analyze and compare literature involving the production of influenza pseudotypes with particular emphasis on their use in serum antibody neutralization assays. This will enable us to establish the parameters required for optimization and propose a consensus protocol to be employed for the further deployment of these assays in influenza vaccine immunogenicity studies.

  4. Microcoupon Assay Of Adhesion And Growth Of Bacterial Films

    Science.gov (United States)

    Pierson, Duane L.; Koenig, David W.

    1994-01-01

    Microbiological assay technique facilitates determination of some characteristics of sessile bacteria like those that attach to and coat interior walls of water-purification systems. Biofilms cause sickness and interfere with purification process. Technique enables direct measurement of rate of attachment of bacterial cells, their metabolism, and effects of chemicals on them. Used to quantify effects of both bactericides and growth-stimulating agents and in place of older standard plate-count and tube-dilution techniques.

  5. Sandwich enzyme-linked immunosorbent assay for naringin.

    Science.gov (United States)

    Qu, Huihua; Wang, Xueqian; Qu, Baoping; Kong, Hui; Zhang, Yue; Shan, Wenchao; Cheng, Jinjun; Wang, Qingguo; Zhao, Yan

    2016-01-15

    Among the currently used immunoassay techniques, sandwich ELISA exhibits higher specificity, lower cross-reactivity, and a wider working range compared to the corresponding competitive assays. However, it is difficult to obtain a pair of antibodies that can simultaneously bind to two epitopes of a molecule with a molecular weight of less than 1000 Da. Naringin (Nar) is a flavonoid with a molecular mass of 580 Da. The main aim of this study was to develop a sandwich ELISA for detecting Nar. Two hybridomas secreting anti-Nar monoclonal antibodies (mAbs) were produced by fusing splenocytes from a mouse immunised against Nar-bovine serum albumin (BSA) conjugated with a hypoxanthine-aminopterin-thymidine (HAT)-sensitive mouse myeloma cell line; a sandwich ELISA for detecting Nar was developed using these two well-characterised anti-Nar mAbs. The performance of the sandwich assay was further evaluated by limit of detection (LOD), limit of quantification (LOQ), recovery, and interference analyses. A dose-response curve to Nar was obtained with an LOD of 6.78 ng mL(-1) and an LOQ of 13.47 ng mL(-1). The inter-assay and intra-assay coefficients of variation were 4.32% and 7.48%, respectively. The recovery rate of Nar from concentrated Fructus aurantii granules was 83.63%. A high correlation was obtained between HPLC and sandwich ELISA. These results demonstrate that the sandwich ELISA method has higher specificity for Nar than indirect competitive ELISA. PMID:26709308

  6. Enzyme-linked immunosorbent assay for group B streptococcal antibodies.

    OpenAIRE

    Rote, N S; N. L. TAYLOR; Shigeoka, A O; Scott, J R; Hill, H R

    1980-01-01

    We report here on the development of enzyme-linked immunosorbent assays (ELISAs) for antibodies to types II and III group B streptococci. Streptococcal antigens were prepared by trichloroacetic acid extraction and fractional alcohol precipitation. Microtiter wells were coated with antigen in 0.1 M carbonate buffer at pH 9.6. Lyophilization was found to be an essential step for efficient binding of the streptococcal antigens. After incubation with antibody-containing rabbit serum, bound antibo...

  7. Development of in vitro assay method with radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Woon; Lim, S. M.; An, S. H.; Woo, K. S.; Chung, W. S.; Lim, S. J.; Hong, S. W. [Korea Atomic Energy Research Institute. Korea Cancer Center Hospital, Seoul (Korea, Republic of); Oh, O. D. [Yonsei University, Seoul (Korea, Republic of)

    1999-04-01

    Radioimmunoassay (RIA) and related competitive protein-binding methods began a little over 20 years ago as a cumbersome research methodology in a few specialized laboratories. Endocrinology has been greatly enriched by the new knowledge that has come as a direct result of RIA methods. Establishment of the taxol RIA system will be expected to develop RIA for drug monitoring. Scintillation proximity assay was useful since any separation step is not required, it has the advantage of dealing with multiple samples. The increased sensitivity of the new assay in determining HCV RT([{sup 125}I]dUTP) suggests that it would be worth investigating whether the system can be applied to analysis. [{sup 125}I] lodotyramine with 98.5% radiochemical purity. Optimal background counts was certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result concentration of hCG from unknown serum was determined by synthesized successively and purified by HPLC system. Hybridoma reducing monoclonal anti thyroglobulin antibodies titer is measured by ELISA. These studies play an important role in development of in vitro assay with radionuclides.

  8. Bio-barcode gel assay for microRNA

    Science.gov (United States)

    Lee, Hyojin; Park, Jeong-Eun; Nam, Jwa-Min

    2014-02-01

    MicroRNA has been identified as a potential biomarker because expression level of microRNA is correlated with various cancers. Its detection at low concentrations would be highly beneficial for cancer diagnosis. Here, we develop a new type of a DNA-modified gold nanoparticle-based bio-barcode assay that uses a conventional gel electrophoresis platform and potassium cyanide chemistry and show this assay can detect microRNA at aM levels without enzymatic amplification. It is also shown that single-base-mismatched microRNA can be differentiated from perfectly matched microRNA and the multiplexed detection of various combinations of microRNA sequences is possible with this approach. Finally, differently expressed microRNA levels are selectively detected from cancer cells using the bio-barcode gel assay, and the results are compared with conventional polymerase chain reaction-based results. The method and results shown herein pave the way for practical use of a conventional gel electrophoresis for detecting biomolecules of interest even at aM level without polymerase chain reaction amplification.

  9. Behavioral assay for assessing effects of pollutants on fish chemoreception

    Energy Technology Data Exchange (ETDEWEB)

    Lemly, A.D.; Smith, R.J.

    1986-04-01

    Behavioral assays are sensitive to sublethal levels of pollution but they usually require highly trained personnel and long observation periods. We describe a system that combines the sensitivity of a behavioral assay with commercially available automated monitoring equipment. The observation system consists of a special aquarium coupled to a recirculating water system, and an Opto-Varimex-Aqua activity tracking meter (Columbus Instruments, Columbus, Ohio) interfaced to a microcomputer. The tracking meter forms an intersecting, planar grid of light beams which, when interrupted by fish movements, is translated into a digitized signal and fed to the computer. The assay is based on the response of fish to natural chemical stimuli such as food odors or pheromones. When these stimulus solutions are injected into the water circulation the response of the fish is monitored by the computer system, which is capable of discriminating and quantifying changes in eight parameters. Normal responses to stimuli are compared with the response of fish that have been exposed to pollutants. We have successfully used this technique to examine effects of reduced pH on the response of fathead minnows, Pimephales promelas, to chemical feeding stimuli. The system should be easily adapted to any laboratory concerned with testing for effects of toxic substances, and will identify effects of pollution that have thus far been difficult or impossible to assess.

  10. Application of statistical process control to qualitative molecular diagnostic assays.

    Directory of Open Access Journals (Sweden)

    Cathal P O'brien

    2014-11-01

    Full Text Available Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control. Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply statistical process control to assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater samples with a resultant protracted time to detection. Modelled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of statistical process control to qualitative laboratory data.

  11. VLLW/Exempt Waste Assay at AWE Using Cronos - 12001

    International Nuclear Information System (INIS)

    Previous studies have indicated that waste bag photon monitors, such as the CANBERRA Cronos-11, have the potential to assay photon emitting uranium (U) and plutonium (Pu) contaminated wastes at the new UK VLLW/exempt waste thresholds of 1 Bq/g U and 0.15 Bq/g Pu. However, the technique has limitations associated with the operation of its plastic scintillation photon detectors. These include the absence of isotopic information and a variable detector background that is modified by the chemical and physical composition of the waste as well as the presence of any naturally occurring radioactive material (NORM). Hence, it is vital to operate Cronos in a low/non-fluctuating background environment and segregate wastes according to isotopic fingerprint, NORM concentration and waste composition. This paper presents results from subsequent Cronos measurements on a range of uncontaminated waste materials, contaminated wastes from Pu and U facilities and a National Physical Laboratory (NPL) waste package standard. The results were consistent with other assay techniques and show that Cronos can be used for exempt waste assay provided that it is operated in a low/non-fluctuating background area and the waste is well segregated before monitoring. (author)

  12. Pu-238 assay performance with the Canberra IQ3 system

    Energy Technology Data Exchange (ETDEWEB)

    Booth, L.; Gillespie, B.; Seaman, G.

    1997-11-01

    Canberra Industries has recently completed a demonstration project at the Westinghouse Savannah River Site (WSRC) to characterize 55-gallon drums containing Pu-238 contaminated waste. The goal of this project was to detect and quantify Pu-238 contaminated waste. The goal of this project was to detect and quantify Pu-238 waste to detection limits of less than 50 nCi/g using gamma assay techniques. This would permit reclassification of these drums from transuranic (TRU) waste to low-level waste (LLW). The instrument used for this assay was a Canberra IQ3 high sensitivity gamma assay system, mounted in a trailer. The results of the measurements demonstrate achievement of detection levels as low as 1 nCi/g for low density waste drums, and good correlation with known concentrations in several test drums. In addition, the data demonstrates significant advantages for using large area low-energy germanium detectors for achieving the lowest possible MDAs for gamma rays in the 80-250 keV range. 1 fig., 2 tabs.

  13. Solid phase group specific absorbants in assays for glycoproteins

    International Nuclear Information System (INIS)

    The focus of this paper is on several technical advances in the assays for glycoprotein hormones and enzymes that have been achieved by use of the solid phase carbohydrate specific adsorbant concanavalin-A. Puriffication of glycoprotein radioligand after labelling by the chloramine-T method is readily accomplished using a small column of agarose bound concanavalin-A which separates glycoprotein radioligand from radioiodide and radiolabelled unadsorbed contaminants. After concanavalin-A column chromatography, radiolabelled glycoprotein hormone preparations exhibited improved binding to antibodies and tissue receptors. To increase the effective sensitivity of radioimmunoassays for glycoproteins, agarose bound concanavalin-A is used to extract and concentrate the glycoproteins from various biologic samples. For example, the effective sensitivity for the detection of human thyrotropin in serum was improved approximately 5 fold by using concanavalin-A concentrates of 1.5 ml of serum. Partial purification of the glycoprotein dopamine-β-hydroxylase from serum using agarose bound concanavalin-A resulted in separation of the serum factors that interfere with the measurement of enzyme activity. We conclude that in assays for glycoproteins, concanavalin-A is useful for purification of radioligand, for preparation of concentrates of glycoproteins from biologic samples, and for separation of glycoproteins from various interfering factors contained in biologic samples prior to radioligand or radioenzyme assay. (orig.)

  14. Toxicity assays in nanodrops combining bioassay and morphometric endpoints.

    Directory of Open Access Journals (Sweden)

    Frédéric Lemaire

    Full Text Available BACKGROUND: Improved chemical hazard management such as REACH policy objective as well as drug ADMETOX prediction, while limiting the extent of animal testing, requires the development of increasingly high throughput as well as highly pertinent in vitro toxicity assays. METHODOLOGY: This report describes a new in vitro method for toxicity testing, combining cell-based assays in nanodrop Cell-on-Chip format with the use of a genetically engineered stress sensitive hepatic cell line. We tested the behavior of a stress inducible fluorescent HepG2 model in which Heat Shock Protein promoters controlled Enhanced-Green Fluorescent Protein expression upon exposure to Cadmium Chloride (CdCl2, Sodium Arsenate (NaAsO2 and Paraquat. In agreement with previous studies based on a micro-well format, we could observe a chemical-specific response, identified through differences in dynamics and amplitude. We especially determined IC50 values for CdCl2 and NaAsO2, in agreement with published data. Individual cell identification via image-based screening allowed us to perform multiparametric analyses. CONCLUSIONS: Using pre/sub lethal cell stress instead of cell mortality, we highlighted the high significance and the superior sensitivity of both stress promoter activation reporting and cell morphology parameters in measuring the cell response to a toxicant. These results demonstrate the first generation of high-throughput and high-content assays, capable of assessing chemical hazards in vitro within the REACH policy framework.

  15. Hydroponic Growth and the Nondestructive Assay for Dinitrogen Fixation 1

    Science.gov (United States)

    Imsande, John; Ralston, Edward J.

    1981-01-01

    Hydroponic growth medium must be well buffered if it is to support sustained plant growth. Although 1.0 millimolar phosphate is commonly used as a buffer for hydroponic growth media, at that concentration it is generally toxic to a soybean plant that derives its nitrogen solely from dinitrogen fixation. On the other hand, we show that 1.0 to 2.0 millimolar 2-(N-morpholino)ethanesulfonic acid, pKa 6.1, has excellent buffering capacity, and it neither interferes with nor contributes nutritionally to soybean plant growth. Furthermore, it neither impedes nodulation nor the assay of dinitrogen fixation. Hence, soybean plants grown hydroponically on a medium supplemented with 1.0 to 2.0 millimolar 2-(N-morpholino)ethanesulfonic acid and 0.1 millimolar phosphate achieve an excellent rate of growth and, in the absence of added fixed nitrogen, attain a very high rate of dinitrogen fixation. Combining the concept of hydroponic growth and the sensitive acetylene reduction technique, we have devised a simple, rapid, reproducible assay procedure whereby the rate of dinitrogen fixation by individual plants can be measured throughout the lifetime of those plants. The rate of dinitrogen fixation as measured by the nondestructive acetylene reduction procedure is shown to be approximately equal to the rate of total plant nitrogen accumulation as measured by Kjeldahl analysis. Because of the simplicity of the procedure, one investigator can readily assay 50 plants individually per day. PMID:16662112

  16. Characterization of mesenchymal stromal cells: potency assay development.

    Science.gov (United States)

    Hematti, Peiman

    2016-04-01

    Based on their many different mechanisms of action, presumed immune-privileged status, and relative ease of production, mesenchymal stromal cells (MSCs) are under intensive clinical investigation for treating a wide range of degenerative, inflammatory, and immunologic disorders. Identification of relevant and robust potency assays is not only a regulatory requirement, but it is also the basis for producing and delivering a product that is consistent, safe, and ultimately an effective therapy. Although development of an appropriate potency assay is one of the most challenging issues in cell-based therapies, it is of paramount importance in the process of developing and testing cellular products. Regardless of the many different tissue sources and methods used in culture expansion of MSCs, they possess many of the same morphologic, cell surface markers, and differentiation characteristics. However, MSC products with similar phenotypic characteristics could still have major differences in their biologic and functional attributes. Understanding the different mechanisms of action and establishment of relevant potency assays is of pivotal importance in allowing investigators and regulatory agencies to compare MSCs used in different clinical trials. PMID:27079322

  17. Ecogenotoxicity testing of aquatic environment by comet assay in plants

    Directory of Open Access Journals (Sweden)

    Anita Mukherjee

    2015-05-01

    Full Text Available One of the goals of environmental monitoring is the detection of potentially hazardous compounds in water. We have set up a standard method to apply the Comet assay in aquatic plants that could be of great interest to evaluate cytotoxicity, genotoxicity and oxidative stress on the same species regarded as most sensitive to environmental pollutants. The aim of the present study was to set up of standardized procedure to evaluate genotoxicity in aquatic plants- Ceratophyllum demersum one that is submerged free floating and the other is Lemna minor - a fresh water floating plant by Comet assay. Electrophoresis and unwinding times were adapted to obtain minimum DNA migration evaluated as tail intensity % or tail moment in the control group and, at the same time maximum sensitivity for DNA damage with known genotoxicants. We further investigated the cytotoxicity and oxidative stress induced in the same species. Based on the repeatability of results obtained we suggest that Ceratophyllum, Lemna can serve as model species and Comet assay could be adopted to monitor the eco-genotoxicity of water pollutants.

  18. New competition assay for the solubilized hepatic galactosyl receptor

    Energy Technology Data Exchange (ETDEWEB)

    Ray, D.A.; Weigel, P.H.

    1985-02-15

    The present method of quantitating soluble asialoglycoprotein (galactosyl) receptor activity relies on the selective precipitation of receptor-ligand complexes to allow separation from free ligand. To provide an alternative to selective precipitation procedures, a simple and rapid method to assay for detergent-solubilized galactosyl receptor activity has been developed which uses permeabilized, fixed cells as a source of immobilized solid-phase receptors. Isolated rat hepatocytes were treated with digitonin to make available the internal as well as the external receptors. The permeable cells were also treated with glutaraldehyde to prevent further protein loss during subsequent exposure to detergents such as Triton X-100. The permeable/fixed cells, which retained about 70% of their total /sup 125/I-asialo-orosomucoid (/sup 125/I-ASOR)-binding activity, with 89% specific binding, were insoluble even in 0.5% Triton X-100 and were easily pelleted. The permeable/fixed cells can be prepared in advance and stored frozen for months. A detergent extract of receptor is mixed with a constant amount of both /sup 125/I-ASOR and permeable/fixed cells. Soluble active receptors compete with immobilized receptors on the treated cell for binding of the /sup 125/I-ASOR. The assay is reproducible, linear over a broad range of soluble receptor concentration, and can quantitate receptor activity from as few as 10(5) hepatocytes. A modified purification procedure for the rat hepatic galactosyl receptor using this competition assay is also described.

  19. Compact L-edge densitometer for uranium concentration assay

    International Nuclear Information System (INIS)

    A new L-edge densitometer has been designed around a compact, commercial x-ray generator weighing less than 5 kg. The dc generator x-ray spectrum was tailored to produce a continuum of x-ray energies from 14 to 20 keV. The x rays were transmitted through uranium reference solutions, and the measured transmissions near the uranium L/sub III/-absorption edge were used to compute the uranium concentration assay result. The range of uranium concentrations in the reference solutions included 5 to 50 g/l. In this concentration range, the assay uncertainty for short count times and the flatness of the specific assay response were better than 0.5%. Thus, the precision and accuracy of this compact densitometer are equal to those demonstrated previously for the L-edge technique. The compact dimensions and optimized transmission geometry increase the practicality, versatility, and range of the L-edge applications. 12 references, 12 figures, 4 tables

  20. Assay in engine of agricultural tractor with biofuel

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Reny Adilmar Prestes; Meyer, Wagner [Universidade Estadual de Maringa (DEA/CCA/UEM), Cidade Gaucha, PR (Brazil). Centro de Ciencias Agrarias. Dept. de Engenharia Agricola], E-mail: raplopes@uem.br; Pinheiro Neto, Raimundo; Pinheiro, Andreia Cristina [Universidade Estadual de Maringa (DAG/CCA/UEM), PR (Brazil). Centro de Ciencias Agrarias. Dept. de Agronomia; Laurindo, Jose Carlos [Instituto de Tecnologia do Parana (CERBIO/TECPAR), Curitiba, PR (Brazil). Centro Brasileiro de Referencia em Biocombustiveis; Biazzono, Sergio Luis [Instituto de Tecnologia do Parana (TECPAR), Maringa, PR (Brazil). Inspecao Veicular

    2008-07-01

    The use of biofuel in tractors of diesel engines and agricultural harvester, in the operations of soil preparation and harvest, is a good option of fuel economy for the agriculturist. For a good performance of the machine a good regulation is necessary. The experiment was carried through in the Experimental Farm Iguatemi of the State University of Maringa, Maringa - PR. A tractor Massey Ferguson MF275 was used for the assay connected to be even grating. It carried through if the assays of consumption of diesel (100%) and biofuel (diesel 80% + vegetable oil 20%). To carry through the assay tractor + grating with three openings and without load was used to be even set. The rotation without load and of work was of 1900 rpm and mean speed of 6 km h{sup -1}. The hourly consumption was verified by a test tube and a fluxgate OVAL Flow mate M III - LSF 45L0-M2 connected to data logger CR23X. The hourly consumption was express in L h{sup -1}. The engine of the tractor presented similar behavior of fuel consumption for diesel and biofuel. The mean values of consumption had been inside of the specified one for the manufacturer. Mixture 80% diesel + 20% vegetable oil can be used as biofuel in the engine in study. (author)

  1. Fluidic Force Discrimination Assays: A New Technology for Tetrodotoxin Detection

    Directory of Open Access Journals (Sweden)

    Cy R. Tamanaha

    2010-03-01

    Full Text Available Tetrodotoxin (TTX is a low molecular weight (~319 Da neurotoxin found in a number of animal species, including pufferfish. Protection from toxin tainted food stuffs requires rapid, sensitive, and specific diagnostic tests. An emerging technique for the detection of both proteins and nucleic acids is Fluidic Force Discrimination (FFD assays. This simple and rapid method typically uses a sandwich immunoassay format labeled with micrometer-diameter beads and has the novel capability of removing nonspecifically attached beads under controlled, fluidic conditions. This technique allows for near real-time, multiplexed analysis at levels of detection that exceed many of the conventional transduction methods (e.g., ELISAs. In addition, the large linear dynamic range afforded by FFD should decrease the need to perform multiple sample dilutions, a common challenge for food testing. By applying FFD assays to an inhibition immunoassay platform specific for TTX and transduction via low magnification microscopy, levels of detection of ~15 ng/mL and linear dynamic ranges of 4 to 5 orders of magnitude were achieved. The results from these studies on the first small molecule FFD assay, along with the impact to detection of seafood toxins, will be discussed in this manuscript.

  2. Homogeneous time resolved fluorescence assay to measure histamine release.

    Science.gov (United States)

    Claret, Emmanuel J; Ouled-Diaf, Josy; Seguin, Patrick

    2003-12-01

    Histamine is a biogenic amine synthesized by the enzymatic decarboxylation of histidine. Implication of histamine in allergy is well described but histamine is also found in some specific neurones, functions as a neurotransmitter and regulates sleep/wake cycles, hormonal secretion, cardiovascular control and thermo-regulation. We have developed a TR-FRET histamine assay, based on the competition between sample histamine and allophycocyanine (XL665) labelled histamine for binding to a Europium cryptate (EuK) labelled antibody. As histamine is a small monoamine molecule, high affinity antibodies have been raised against carrier protein conjugated histamine. Therefore, sample histamine needs to be derivatized in the same way as the conjugated histamine, so that the antibody will have a similar affinity for both molecules. This acylation step is performed directly in wells and does not need to be done in separate vials, making handling easier for large numbers of samples. The incubation takes place at room temperature for 3 hours. The assay covers a measurement range of 1.56 to 400 nM and shows an analytical sensitivity of 1.3nM. We have shown that miniaturization of sample and reagents volumes down to 20 micro l does not alter these performances. This histamine release assay provides a particularly well adapted procedure for HTS and secondary screening compared to current heterogeneous methods. PMID:14683484

  3. Radioactive waste package assay facility. Final report - V. A

    International Nuclear Information System (INIS)

    This report provides a summary of research work carried out in support of the development of an integrated assay system for the quality checking of Intermediate Level Waste encapsulated in cement. Four non-destructive techniques were originally identified as being viable methods for obtaining radiometric inventory data from a cemented 500 litre ILW package. The major part of the programme was devoted to the development of two interrogation techniques; active neutron for measuring the total fissile content and active gamma for measuring the total actinide content. An electron linear accelerator was used to supply the interrogating beam for these two methods. In addition the linear accelerator beam could be used for high energy radiography. The results of this work are described and the performances and limitations of the non-destructive methods are summarised. The main engineering and operational features which influence the design of an integrated assay facility are outlined and a conceptual layout for a facility to inspect 750 ILW drums a year is described. Details of the detection methods, data processing and potential application of the assay facility are given in three associated HMIP reports. (Author)

  4. Development of in vitro assay method with radioisotope

    International Nuclear Information System (INIS)

    Radioimmunoassay (RIA) and related competitive protein-binding methods began a little over 20 years ago as a cumbersome research methodology in a few specialized laboratories. Endocrinology has been greatly enriched by the new knowledge that has come as a direct result of RIA methods. Establishment of the taxol RIA system will be expected to develop RIA for drug monitoring. Scintillation proximity assay was useful since any separation step is not required, it has the advantage of dealing with multiple samples. The increased sensitivity of the new assay in determining HCV RT([125I]dUTP) suggests that it would be worth investigating whether the system can be applied to analysis. [125I] lodotyramine with 98.5% radiochemical purity. Optimal background counts was certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result concentration of hCG from unknown serum was determined by synthesized successively and purified by HPLC system. Hybridoma reducing monoclonal anti thyroglobulin antibodies titer is measured by ELISA. These studies play an important role in development of in vitro assay with radionuclides

  5. Biosensor assay for determination of haptoglobin in bovine milk.

    Science.gov (United States)

    Akerstedt, Maria; Björck, Lennart; Persson Waller, Karin; Sternesjö, Ase

    2006-08-01

    Despite more than 30 years of research into mastitis diagnostics, there are few alternatives to the somatic cell count (SCC) in practical use for identification of cows with subclinical mastitis. Mastitis is not only an animal welfare problem, but also affects the yield, composition and technological properties of milk. Hence, dairy cooperatives give farmers a premium quality payment to encourage low SCC although there is no clear scientific data defining the level of SCC in bulk tank milk that is associated with additional benefits in terms of milk quality. Recent research on alternative markers for inflammatory reactions in the lactating cow, e.g. in mastitis, includes investigations of the acute phase protein, haptoglobin (Hp). So far, the content of Hp in milk has mainly been studied in relation to mastitis diagnostics, with little attention given to its importance for milk composition and technological properties. At present, Hp in milk is measured using ELISA, but this technique is not suitable for routine large-scale analysis. In recent years, optical biosensor technology has been used for automated and rapid quantitative analysis of different components in milk, but so far not for analysis of acute phase proteins. The aim of the present study was to develop a rapid and sensitive biosensor method to determine Hp in milk. An affinity sensor assay based on the interaction between Hp and haemoglobin was developed using surface plasmon resonance (SPR) biosensor technology. The assay was used to analyse Hp in composite milk samples from cows without any clinical signs of mastitis and quarter milk samples with a weak to strong reaction in the California Mastitis Test (CMT). A commercial ELISA for determination of Hp in milk was used for comparison. The limit of detection (LOD) of the biosensor assay was determined as 1.1 mg/l. Within-assay and between-day variations were determined both with bulk tank milk spiked with human Hp and with composite milk samples

  6. Comparison of three multiplex PCR assays for the detection of respiratory viral infections: evaluation of xTAG respiratory virus panel fast assay, RespiFinder 19 assay and RespiFinder SMART 22 assay

    Directory of Open Access Journals (Sweden)

    Dabisch-Ruthe Mareike

    2012-07-01

    Full Text Available Abstract Background A broad spectrum of pathogens is causative for respiratory tract infections, but symptoms are mostly similar. Therefore, the identification of the causative viruses and bacteria is only feasible using multiplex PCR or several monoplex PCR tests in parallel. Methods The analytical sensitivity of three multiplex PCR assays, RespiFinder-19, RespiFinder-SMART-22 and xTAG-Respiratory-Virus-Panel-Fast-Assay (RVP, were compared to monoplex real-time PCR with quantified standardized control material. All assays include the most common respiratory pathogens. Results To compare the analytical sensitivity of the multiplex assays, samples were inoculated with 13 different quantified viruses in the range of 101 to 105 copies/ml. Concordant results were received for rhinovirus, whereas the RVP detected influenzavirus, RSV and hMPV more frequently in low concentrations. The RespiFinder-19 and the RespiFinder-SMART-22 showed a higher analytical sensitivity for adenoviruses and coronaviruses, whereas the RVP was incapable to detect adenovirus and coronavirus in concentrations of 104 copies/ml. The RespiFinder-19 and RespiFinder-SMART-22A did not detect influenzaviruses (104 copies/ml and RSV (103 copies/ml. The detection of all 13 viruses in one sample was only achieved using monoplex PCR. To analyze possible competitive amplification reactions between the different viruses, samples were further inoculated with only 4 different viruses in one sample. Compared to the detection of 13 viruses in parallel, only a few differences were found. The incidence of respiratory viruses was compared in tracheal secretion (TS samples (n = 100 of mechanically ventilated patients in winter (n = 50 and summer (n = 50. In winter, respiratory viruses were detected in 32 TS samples (64% by RespiFinder-19, whereas the detection rate with RVP was only 22%. The most frequent viruses were adenovirus (32% and PIV-2 (20%. Multiple infections were detected

  7. Quantitative lipopolysaccharide analysis using HPLC/MS/MS and its combination with the limulus amebocyte lysate assay[S

    OpenAIRE

    Pais De Barros, Jean-Paul; Gautier, Thomas; Sali, Wahib; Adrie, Christophe; Choubley, Hélène; Charron, Emilie; Lalande, Caroline; Le Guern, Naig; Deckert, Valérie; Monchi, Mehran; Quenot, Jean-Pierre; Lagrost, Laurent

    2015-01-01

    Quantitation of plasma lipopolysaccharides (LPSs) might be used to document Gram-negative bacterial infection. In the present work, LPS-derived 3-hydroxymyristate was extracted from plasma samples with an organic solvent, separated by reversed phase HPLC, and quantitated by MS/MS. This mass assay was combined with the limulus amebocyte lysate (LAL) bioassay to monitor neutralization of LPS activity in biological samples. The described HPLC/MS/MS method is a reliable, practical, accurate, and ...

  8. Premarket Evaluations of the IMDx C. difficile for Abbott m2000 Assay and the BD Max Cdiff Assay

    OpenAIRE

    Stellrecht, K A; Espino, A. A.; Maceira, V. P.; Nattanmai, S. M.; Butt, S. A.; Wroblewski, D.; Hannett, G. E.; Musser, K. A.

    2014-01-01

    Clostridium difficile-associated diarrhea is a well-recognized complication of antibiotic use. Historically, diagnosing C. difficile has been difficult, as antigen assays are insensitive and culture-based methods require several days to yield results. Nucleic acid amplification tests (NAATs) are quickly becoming the standard of care. We compared the performance of two automated investigational/research use only (IUO/RUO) NAATs for the detection of C. difficile toxin genes, the IMDx C. diffici...

  9. Expansion of a SNaPshot assay to a 55-SNP multiplex: Assay enhancements, validation, and power in forensic science.

    Science.gov (United States)

    Wang, Qian; Fu, Lihong; Zhang, Xiaojing; Dai, Xinyu; Bai, Mei; Fu, Guangping; Cong, Bin; Li, Shujin

    2016-05-01

    A previously developed multiplex assay with 44 individual identification SNPs was expanded to a 55plex assay. Fifty-four highly informative SNPs and an amelogenin sex marker were amplified in one PCR reaction and then detected with two SNaPshot reactions using CE. PCR primers for four loci, 28 single-base extension primers, and the reaction conditions were altered to improve the robustness of the method. A detailed approach for allele calling was developed to guide analysis of the electropherogram. One hundred and eighty unrelated individuals and 100 father-child-mother trios of the Han population in Hebei, China were analyzed. No mutation was found in the SNP loci. The combined mean match probability and cumulative probability of exclusion were 1.327 × 10(-22) and 0.999932, respectively. Analysis of the 54 SNPs and 26 STRs (included in the AmpFLSTR Identifiler and Investigator HDplex kits) showed no significant linkage disequilibriums. Our research shows that the expanded SNP multiplex assay is an easily performed and valuable method to supplement STR analysis.

  10. Investigating the genetic instability in the peripheral lymphocytes of 36 untreated lung cancer patients with comet assay and micronucleus assay

    International Nuclear Information System (INIS)

    The aim of present investigation was to study the genetic instability in peripheral lymphocytes of lung cancer patients. The micronucleus (MN) assay and comet assay were simultaneously used to detect the spontaneous genetic change and ionizing irradiation (IR) induced genetic damage in peripheral lymphocytes from 36 lung cancer patients and 30 controls. In MN assay, the results of both two indicators, micronucleated cell frequency (MCF) and micronucleus frequency (MNF), indicated that the average values of MCF, MNF and IR-induced MCF, MNF of lung cancer patients were 9.25 ± 0.58, 10.17 ± 0.72, 66.14 ± 2.07 and 75.64 ± 2.34 per mille , respectively, which were significantly higher than those (6.10 ± 0.65, 6.60 ± 0.74, 60.50 ± 1.71 and 67.60 ± 2.13 per mille ) of controls (P 0.05). The results of present investigation indicated that the genetic instability in peripheral lymphocytes of 36 lung cancer patients was significantly higher than that of controls

  11. A High-Throughput Assay for Rho Guanine Nucleotide Exchange Factors Based on the Transcreener GDP Assay.

    Science.gov (United States)

    Reichman, Melvin; Schabdach, Amanda; Kumar, Meera; Zielinski, Tom; Donover, Preston S; Laury-Kleintop, Lisa D; Lowery, Robert G

    2015-12-01

    Ras homologous (Rho) family GTPases act as molecular switches controlling cell growth, movement, and gene expression by cycling between inactive guanosine diphosphate (GDP)- and active guanosine triphosphate (GTP)-bound conformations. Guanine nucleotide exchange factors (GEFs) positively regulate Rho GTPases by accelerating GDP dissociation to allow formation of the active, GTP-bound complex. Rho proteins are directly involved in cancer pathways, especially cell migration and invasion, and inhibiting GEFs holds potential as a therapeutic strategy to diminish Rho-dependent oncogenesis. Methods for measuring GEF activity suitable for high-throughput screening (HTS) are limited. We developed a simple, generic biochemical assay method for measuring GEF activity based on the fact that GDP dissociation is generally the rate-limiting step in the Rho GTPase catalytic cycle, and thus addition of a GEF causes an increase in steady-state GTPase activity. We used the Transcreener GDP Assay, which relies on selective immunodetection of GDP, to measure the GEF-dependent stimulation of steady-state GTP hydrolysis by small GTPases using Dbs (Dbl's big sister) as a GEF for Cdc42, RhoA, and RhoB. The assay is well suited for HTS, with a homogenous format and far red fluorescence polarization (FP) readout, and it should be broadly applicable to diverse Rho GEF/GTPase pairs.

  12. Comparison of Two Nucleic Acid Amplification Assays, the Xpert MTB/RIF Assay and the Amplified Mycobacterium Tuberculosis Direct Assay, for Detection of Mycobacterium tuberculosis in Respiratory and Nonrespiratory Specimens▿

    OpenAIRE

    Teo, Jeanette; Jureen, Roland; Chiang, Donald; Chan, Douglas; Lin, Raymond

    2011-01-01

    We compared the performance of the Xpert MTB/RIF assay, a new real-time tuberculosis (TB) PCR test, with that of the Amplified Mycobacterium Tuberculosis Direct (MTD) assay using 162 respiratory and nonrespiratory specimens. Based on culture as the gold standard, the overall sensitivity and specificity for all sample types for the Xpert MTB/RIF assay were 90.9 and 89%, respectively, while for the MTD assay, the overall sensitivity and specificity were 97.3 and 87.1%, respectively. A higher pr...

  13. [Comparison of the clinical performance of the ECLusys HIV combi assay with the Lumipulse f and HISCL 2000-i HIV-1/2 ab screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-04-01

    We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.

  14. Optimization of a colorimetric assay for glycosylated human serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Bohney, J.P.; Feldhoff, R.C.

    1986-05-01

    The thiobarbituric acid (TBA) assay has been used for several years to quantitate the amount of glucose which has been non-enzymatically linked to hemoglobin and other proteins. The ketoamine-protein adduct is converted to 5-hydroxymethylfurfural (HMF) by mild hydrolysis with oxalic acid. Reaction of HMF with TBA yields a colored product which has an absorbance maximum at 443 nm. Several modifications of the original procedure has been published, but none permit the unambiguous quantitation of glycosylated human serum albumin (glc-HSA). Problems relate to reagent preparation and stability, the time and temperature of hydrolysis, the choice of standards, and background color corrections. The authors have found that maximum color yield occurs after hydrolysis in an autoclave for 2 h. This increases the sensitivity 3-fold and cuts the assay time in half relative to hydrolysis for 4.5 h at 100/sup 0/C. A NaBH/sub 4/ reduction of a parallel protein sample must be performed to correct for variable background color associated with different sample sources and amounts. HMF can be used as a standard, however, corrections must be made for HMF degradation. Fructose is a better standard, but HMF formation from fructose is faster than formation from glc-HSA. This may result in an underestimate of percent glycosylation. The best standard appears to be glc-HSA prepared with (/sup 3/H)glucose. It appears that with proper controls and standards the TBA assay can be used to determine actual rather than relative percent glycosylation.

  15. Detection of irradiated onion by means of the comet assay

    Energy Technology Data Exchange (ETDEWEB)

    Moreno Alvarez, Damaris L.; Prieto Miranda, Enrique Fco.; Carro Palacio, Sandra [Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear. (CEADEN), Ciudad de La Habana (Cuba)]. E-mail: damaris@ceaden.edu.cu; efprieto@ceaden.edu.cu; Iglesia Enriquez, Isora [Instituto de Investigacion para la Industria Alimenticia (IIIA), Ciudad de La Habana (Cuba)

    2007-07-01

    The ionizing radiations are used as a harmless alternative treatment that it substitutes the employment of chemical treatments, which after their application in the food products can remain residuals not desired that they come to be carcinogenic. With the food irradiation is eliminated microorganisms and the storage time is prolonged, which produces benefits for the Food Industry and the consumers. In many countries the search of sensitive detecting methods of irradiated foods is promoted by the necessity of the assurance of the consumption of foods with nutritional quality and to test directly the radiation processing, for which several techniques have been developed, these are based on the changes that induce the ionizing radiations in the food products. A recommended method is the Comet Assay of DNA, it is approved by the European Committee of Standardization (EN 13784). The DNA molecule is very sensitive to gamma radiations even at low radiation dose, where the modifications produced in the molecule can be monitored for this analytical technique well-known as Comet Assay of DNA or Single Cell Gel Electrophoresis. The objective of the present paper was to evaluate the modifications of the DNA molecule of irradiated onions with the Comet Assay for several dose values, the onions were conserved at environment and refrigeration temperatures. The samples were irradiated in a self-shielding irradiator with {sup 60}Co source, dose rate of 20.45 Gy/min and absorbed dose values of 0.5; 0.6; 0.8 and 1.0 kGy. This detection method demonstrates to be one sensitive and quick technique for the qualitative detection of irradiated onions. (author)

  16. Detection of irradiated onion by means of the comet assay

    International Nuclear Information System (INIS)

    The ionizing radiations are used as a harmless alternative treatment that it substitutes the employment of chemical treatments, which after their application in the food products can remain residuals not desired that they come to be carcinogenic. With the food irradiation is eliminated microorganisms and the storage time is prolonged, which produces benefits for the Food Industry and the consumers. In many countries the search of sensitive detecting methods of irradiated foods is promoted by the necessity of the assurance of the consumption of foods with nutritional quality and to test directly the radiation processing, for which several techniques have been developed, these are based on the changes that induce the ionizing radiations in the food products. A recommended method is the Comet Assay of DNA, it is approved by the European Committee of Standardization (EN 13784). The DNA molecule is very sensitive to gamma radiations even at low radiation dose, where the modifications produced in the molecule can be monitored for this analytical technique well-known as Comet Assay of DNA or Single Cell Gel Electrophoresis. The objective of the present paper was to evaluate the modifications of the DNA molecule of irradiated onions with the Comet Assay for several dose values, the onions were conserved at environment and refrigeration temperatures. The samples were irradiated in a self-shielding irradiator with 60Co source, dose rate of 20.45 Gy/min and absorbed dose values of 0.5; 0.6; 0.8 and 1.0 kGy. This detection method demonstrates to be one sensitive and quick technique for the qualitative detection of irradiated onions. (author)

  17. Evaluation of human sperm DNA alterations: comet assay

    International Nuclear Information System (INIS)

    Full text: Reactive oxygen species would be able to generate base oxidation and strand breaks at the sperm DNA. These alterations could impair the embryo development or the differentiation of any of the embryonic cellular progenies if the fertilization takes place. The aim of the study was to develop the method of single cell gel electrophoresis or comet assay, with slight modifications, in order to investigate the effects on human sperm DNA caused by the oxidative stress induced by H2O2 or the exposure to ionizing radiation. Motile spermatozoa from samples of normozoospermic donors were exposed to increasing concentrations of H2O2 (17,6 μM to 140,8 μM) or UV radiation (15 W for 1 h). Then, the sperm cells, included in 1% agarose gels, were electrophoresed under alkaline conditions (20 V for 5 min). The sperm DNA was stained with the silver method. The total length of sperm DNA migration for each treatment group was assessed using a microscope. The statistical analysis of the mean results among the different treatments was performed by the ANOVA test followed by the Dunn' test or by the Student t-test when only one treatment was applied. The results of the comet assays showed significant dose-dependent increases in sperm DNA migration for spermatozoa treated with H2O2 respect to controls (p 2O2 treatment, the UV radiation would cause the cross-linking of the nucleotides, which could explain the observed results. The comet assay appears to be a sensitive method to assess potential damages in human sperm DNA. (author)

  18. Enzymatic assay for calmodulins based on plant NAD kinase activity

    Energy Technology Data Exchange (ETDEWEB)

    Harmon, A.C.; Jarrett, H.W.; Cormier, M.J.

    1984-01-01

    NAD kinase with increased sensitivity to calmodulin was purified from pea seedlings (Pisum sativum L., Willet Wonder). Assays for calmodulin based on the activities of NAD kinase, bovine brain cyclic nucleotide phosphodiesterase, and human erythrocyte Ca/sup 2 -/-ATPase were compared for their sensitivities to calmodulin and for their abilities to discriminate between calmodulins from different sources. The activities of the three enzymes were determined in the presence of various concentrations of calmodulins from human erythrocyte, bovine brain, sea pansy (Renilla reniformis), mung bean seed (Vigna radiata L. Wilczek), mushroom (Agaricus bisporus), and Tetrahymena pyriformis. The concentrations of calmodulin required for 50% activation of the NAD kinase (K/sub 0.5/) ranged from 0.520 ng/ml for Tetrahymena to 2.20 ng/ml for bovine brain. The A/sub 0.5/ s ranged from 19.6 ng/ml for bovine brain calmodulin to 73.5 ng/ml for mushroom calmodulin for phosphodiesterase activation. The K/sub 0.5/'s for the activation of Ca/sup 2 +/-ATPase ranged from 36.3 ng/mol for erythrocyte calmodulin to 61.7 ng/ml for mushroom calmodulin. NAD kinase was not stimulated by phosphatidylcholine, phosphatidylserine, cardiolipin, or palmitoleic acid in the absence or presence of Ca/sup 2 +/. Palmitic acid had a slightly stimulatory effect in the presence of Ca/sup 2 +/ (10% of maximum), but no effect in the absence of Ca/sup 2 +/. Palmitoleic acid inhibited the calmodulin-stimulated activity by 50%. Both the NAD kinase assay and radioimmunoassay were able to detect calmodulin in extracts containing low concentrations of calmodulin. Estimates of calmodulin contents of crude homogenates determined by the NAD kinase assay were consistent with amounts obtained by various purification procedures. 30 references, 1 figure, 4 tables.

  19. A novel immunological assay for hepcidin quantification in human serum.

    Directory of Open Access Journals (Sweden)

    Vasiliki Koliaraki

    Full Text Available BACKGROUND: Hepcidin is a 25-aminoacid cysteine-rich iron regulating peptide. Increased hepcidin concentrations lead to iron sequestration in macrophages, contributing to the pathogenesis of anaemia of chronic disease whereas decreased hepcidin is observed in iron deficiency and primary iron overload diseases such as hereditary hemochromatosis. Hepcidin quantification in human blood or urine may provide further insights for the pathogenesis of disorders of iron homeostasis and might prove a valuable tool for clinicians for the differential diagnosis of anaemia. This study describes a specific and non-operator demanding immunoassay for hepcidin quantification in human sera. METHODS AND FINDINGS: An ELISA assay was developed for measuring hepcidin serum concentration using a recombinant hepcidin25-His peptide and a polyclonal antibody against this peptide, which was able to identify native hepcidin. The ELISA assay had a detection range of 10-1500 microg/L and a detection limit of 5.4 microg/L. The intra- and interassay coefficients of variance ranged from 8-15% and 5-16%, respectively. Mean linearity and recovery were 101% and 107%, respectively. Mean hepcidin levels were significantly lower in 7 patients with juvenile hemochromatosis (12.8 microg/L and 10 patients with iron deficiency anemia (15.7 microg/L and higher in 7 patients with Hodgkin lymphoma (116.7 microg/L compared to 32 age-matched healthy controls (42.7 microg/L. CONCLUSIONS: We describe a new simple ELISA assay for measuring hepcidin in human serum with sufficient accuracy and reproducibility.

  20. An improved in vitro micronucleus assay to biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ocampo, Ivette Z.; Okazaki, Kayo; Vieira, Daniel P., E-mail: dpvieira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), So Paulo, SP (Brazil)

    2013-07-01

    The biological dosimetry is widely used to estimate the absorbed dose in people occupationally or accidentally exposed to the radiation for a better medical treatment, minimizing the harmful effects. Many techniques and methods have been proposed to detect and quantify the radioinduced lesions in genetic material, among them, the micronucleus (MN) assay. In the present study, we proposed an improved in vitro micronucleus technique that is rapid, sensitive and with minor cell manipulations. Assays were carried out with human tumor cells (MCF-7) seeded (3x10{sup 4} cells) in slides placed into Petri dishes. Adherent cells were maintained with RPMI medium, supplemented with fetal calf serum, 1 % antibiotics, cytochalasin B (2 μg/mL), and incubated at 37 deg C in the presence of 5% CO2 for 72h. Cells were pre-treated for 24h with aminoguanidine, a nitric oxide synthase inhibitor. Nitric oxide is an intracellular free-radical, involved in DNA double-strand break repair mechanisms. After incubation, adherent cells on slides were briefly fixed with paraformaldehyde and stained with acridine orange (100 μg/mL) for analysis through fluorescence microscopy. Dye fluorescence permitted accurate discrimination between nuclei and micronuclei (bright green) and cytoplasm (red), and made possible a faster counting of binucleated cells. Aminoguanidine (2 mM) induced significant increase (p< 0.05) in frequencies of binucleated cells with micronuclei and in the number of micronuclei per binucleated cell. Data showed that proposed modifications permit to understand an early aspect of NO inhibition and suggested an improved protocol to MN assays. (author)

  1. [Clinical evaluation of a novel HBsAg quantitative assay].

    Science.gov (United States)

    Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-07-01

    The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.

  2. Antifungal chemical compounds identified using a C. elegans pathogenicity assay.

    Directory of Open Access Journals (Sweden)

    Julia Breger

    2007-02-01

    Full Text Available There is an urgent need for the development of new antifungal agents. A facile in vivo model that evaluates libraries of chemical compounds could solve some of the main obstacles in current antifungal discovery. We show that Candida albicans, as well as other Candida species, are ingested by Caenorhabditis elegans and establish a persistent lethal infection in the C. elegans intestinal track. Importantly, key components of Candida pathogenesis in mammals, such as filament formation, are also involved in nematode killing. We devised a Candida-mediated C. elegans assay that allows high-throughput in vivo screening of chemical libraries for antifungal activities, while synchronously screening against toxic compounds. The assay is performed in liquid media using standard 96-well plate technology and allows the study of C. albicans in non-planktonic form. A screen of 1,266 compounds with known pharmaceutical activities identified 15 (approximately 1.2% that prolonged survival of C. albicans-infected nematodes and inhibited in vivo filamentation of C. albicans. Two compounds identified in the screen, caffeic acid phenethyl ester, a major active component of honeybee propolis, and the fluoroquinolone agent enoxacin exhibited antifungal activity in a murine model of candidiasis. The whole-animal C. elegans assay may help to study the molecular basis of C. albicans pathogenesis and identify antifungal compounds that most likely would not be identified by in vitro screens that target fungal growth. Compounds identified in the screen that affect the virulence of Candida in vivo can potentially be used as "probe compounds" and may have antifungal activity against other fungi.

  3. Development of versatile universal reagent immunoradiometric assay technique

    International Nuclear Information System (INIS)

    Immunoradiometric assays, which make use of labelled antibodies, potentially offer better sensitivity and specificity than do radioimmunoassays, which use labelled antigens. In addition, they can in principle be performed in a particularly convenient scheme wherein the same labelled reagent may be used for many different analytes - thus serving as a ''universal'' labelled reagent. Thus if the specific antibody for every analyte is raised in rabbits, and an anti-rabbit antibody is labelled, the latter may be added after the specific antibody to quantify the amount of specific antibody bound to analyte and thereby the amount of analyte present. The potential greater sensitivity and specificity of the immunoradiometric procedure, coupled with the potential convenience of the ''universal'' labelled reagent, might allow such immunoradiometric techniques to be used effectively in the study of communicable diseases in developing countries. Development of these procedures was the subject of this investigation. Many components of these procedures had to be explored and provisionally optimized, including coating of assay tubes with ''extraction'' antibody, immunological purification of antibodies, labelling of antibodies, and intermediate steps toward these goals. Applications were thereupon tested using those provisionally optimized components. The ''universal'' labelled reagent, a donkey anti-rabbit antiserum, was successfully used in the assay of TSH; however, cross reactions of the reagent with non-rabbit immunoglobulins and other materials present seriously limited the sensitivity of the method. Using conventional immunoradiometric procedures, circulating TB and amoebic antibodies could be detected in patients suffering from these diseases. Similarly, circulating antigens in the same patients could also be detected, but not with sufficient sensitivity and specificity to provide a reliable analytical system. Numerous improvements will be required before these techniques

  4. Liposome reconstitution and transport assay for recombinant transporters.

    Science.gov (United States)

    Johnson, Zachary Lee; Lee, Seok-Yong

    2015-01-01

    Secondary active transporters are responsible for the cellular uptake of many biologically important molecules, including neurotransmitters, nutrients, and drugs. Because of their physiological and clinical importance, a method for assessing their transport activity in vitro is necessary to gain a better understanding of how these transporters function at the molecular level. In this chapter, we describe a protocol for reconstituting the concentrative nucleoside transporter from Vibrio cholerae into proteoliposomes. We then describe a radiolabeled substrate uptake assay that can be used to functionally characterize the transporter. These methods are relatively common and can be applied to other secondary active transporters, with or without some modification.

  5. Spontaneous and cytokine induced basophil adhesion evaluated by microtiter assay

    DEFF Research Database (Denmark)

    Quan, Sha; Poulsen, Lars K; Reimert, Claus Michael;

    2002-01-01

    We have developed a microtiter assay for evaluating basophil spontaneous adhesion to extracellular matrix (ECM) proteins exemplified by fibronectin and cytokine induced basophil adhesion to bovine serum albumin (BSA). The percentage of basophils adhering to either ECM or BSA was quantified...... by the histamine content of the adhering basophils. The spontaneous adhesion to fibronectin was higher than to laminin and collagen type I. Both spontaneous adhesion to fibronectin and interleukin-3 (IL-3), interleukin-5 (IL-5), granulocyte/macrophage colony stimulating factor (GM-CSF) induced adhesion to BSA...

  6. Nondestructive assay instrumentation for a Savannah River Plant upgrade project

    International Nuclear Information System (INIS)

    We have designed and are developing three different computer-based spectrometer systems. Two will measure the concentration of Pu solutions by gamma-ray and by stimulated x-ray fluorescence emissions of solid samples in closed containers. All systems are coupled to remote terminals and bar code readers, and also to mini-computer based multichannel analyzers, which in turn are linked to another computer to provide a state-of-the-art nondestructive assay capability. Installation at the Savannah River Plant is planned in late 1985. 7 references

  7. An evaluation of the Ramco kit for serum ferritin assay

    International Nuclear Information System (INIS)

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6μg/l to greater than 2 000 μg/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice

  8. Counting colonies of clonogenic assays by using densitometric software

    International Nuclear Information System (INIS)

    Clonogenic assays are a useful tool to test whether a given cancer therapy can reduce the clonogenic survival of tumour cells. A colony is defined as a cluster of at least 50 cells which can often only be determined microscopically. The process of counting colonies is very extensive work and so we developed software that is able to count the colonies automatically from scanned flasks. This software is made freely available by us with a detailed description how to use and install the necessary features

  9. Assay Methods for H2S Biogenesis and Catabolism Enzymes

    Science.gov (United States)

    Banerjee, Ruma; Chiku, Taurai; Kabil, Omer; Libiad, Marouane; Motl, Nicole; Yadav, Pramod K.

    2015-01-01

    H2S is produced from sulfur-containing amino acids, cysteine and homocysteine, or a catabolite, 3-mercaptopyruvate, by three known enzymes: cystathionine β-synthase, γ-cystathionase, and 3-mercaptopyruvate sulfurtransferase. Of these, the first two enzymes reside in the cytoplasm and comprise the transsulfuration pathway, while the third enzyme is found both in the cytoplasm and in the mitochondrion. The following mitochondrial enzymes oxidize H2S: sulfide quinone oxidoreductase, sulfur dioxygenase, rhodanese, and sulfite oxidase. The products of the sulfide oxidation pathway are thiosulfate and sulfate. Assays for enzymes involved in the production and oxidative clearance of sulfide to thiosulfate are described in this chapter. PMID:25725523

  10. Fluorescent Receptor Binding Assay for Detecting Ciguatoxins in Fish.

    Science.gov (United States)

    Hardison, D Ransom; Holland, William C; McCall, Jennifer R; Bourdelais, Andrea J; Baden, Daniel G; Darius, H Taiana; Chinain, Mireille; Tester, Patricia A; Shea, Damian; Quintana, Harold A Flores; Morris, James A; Litaker, R Wayne

    2016-01-01

    Ciguatera fish poisoning is an illness suffered by > 50,000 people yearly after consumption of fish containing ciguatoxins (CTXs). One of the current methodologies to detect ciguatoxins in fish is a radiolabeled receptor binding assay (RBA(R)). However, the license requirements and regulations pertaining to radioisotope utilization can limit the applicability of the RBA(R) in certain labs. A fluorescence based receptor binding assay (RBA(F)) was developed to provide an alternative method of screening fish samples for CTXs in facilities not certified to use radioisotopes. The new assay is based on competition binding between CTXs and fluorescently labeled brevetoxin-2 (BODIPY®-PbTx-2) for voltage-gated sodium channel receptors at site 5 instead of a radiolabeled brevetoxin. Responses were linear in fish tissues spiked from 0.1 to 1.0 ppb with Pacific ciguatoxin-3C (P-CTX-3C) with a detection limit of 0.075 ppb. Carribean ciguatoxins were confirmed in Caribbean fish by LC-MS/MS analysis of the regional biomarker (C-CTX-1). Fish (N = 61) of six different species were screened using the RBA(F). Results for corresponding samples analyzed using the neuroblastoma cell-based assay (CBA-N2a) correlated well (R2 = 0.71) with those of the RBA(F), given the low levels of CTX present in positive fish. Data analyses also showed the resulting toxicity levels of P-CTX-3C equivalents determined by CBA-N2a were consistently lower than the RBA(F) affinities expressed as % binding equivalents, indicating that a given amount of toxin bound to the site 5 receptors translates into corresponding lower cytotoxicity. Consequently, the RBA(F), which takes approximately two hours to perform, provides a generous estimate relative to the widely used CBA-N2a which requires 2.5 days to complete. Other RBA(F) advantages include the long-term (> 5 years) stability of the BODIPY®-PbTx-2 and having similar results as the commonly used RBA(R). The RBA(F) is cost-effective, allows high sample

  11. The Physcomitrella patens System for Transient Gene Expression Assays.

    Science.gov (United States)

    Thévenin, Johanne; Xu, Wenjia; Vaisman, Louise; Lepiniec, Loïc; Dubreucq, Bertrand; Dubos, Christian

    2016-01-01

    Transient expression assays are valuable techniques to study in vivo the transcriptional regulation of gene expression. These methods allow to assess the transcriptional properties of a given transcription factor (TF) or a complex of regulatory proteins against specific DNA motifs, called cis-regulatory elements. Here, we describe a fast, efficient, and reliable method based on the use of Physcomitrella patens protoplasts that allows the study of gene expression in a qualitative and quantitative manner by combining the advantage of GFP (green fluorescent protein) as a marker of promoter activity with flow cytometry for accurate measurement of fluorescence in individual cells. PMID:27557766

  12. Observation and control system of the thermohydraulic assays laboratory

    International Nuclear Information System (INIS)

    The Thermohydraulic Assays Laboratory (L.E.T.) is an installation whose purpose will be the components testing and the CAREM-25 reactor thermohydraulic processes operation dynamics. This plant is located at Pilcaniyeu, province of Rio Negro. Part of the tests which will be carried out consist in the use of different control strategies. The control of the systems by digital processors (control by software) has been decided to proceed with a maximum flexibility and capacity to make changes in the algorithms. This work describes the design and implementation of a digital control system to command the three circuits of the installation. (Author)

  13. Assay for optical determination of biogenic amines using microtiterplates

    Science.gov (United States)

    Nedeljko, Polona; Turel, Matejka; Lobnik, Aleksandra

    2013-05-01

    Direct determination of catecholamine noradreanaline (NOR) is presented using o-phthaldialdehyde (OPA) as an indicator reagent. The fluorescent assay in which OPA forms with NOR a fluorescent complex (OPA-NOR) can be monitored at neutral, physiological conditions (pH 7) and performed in microtiterplates. The determination of NOR is optimal in the concentration range from 4.0×10-7 to 1.0×10-5 M and limit of detection is 4.0×10-7 M. The OPA-NOR complex maximum intensity is reached within 5 minutes. Dopamine and adrenaline could not be determined using the same approach.

  14. Multilaboratory Comparison of Hepatitis C Virus Viral Load Assays

    OpenAIRE

    Caliendo, A M; Valsamakis, A.; Zhou, Y.; Yen-Lieberman, B; Andersen, J; Young, S.; Ferreira-Gonzalez, A; Tsongalis, G. J.; Pyles, R.; Bremer, J W; Lurain, N. S.

    2006-01-01

    We report a multilaboratory evaluation of hepatitis C virus (HCV) viral load assays to determine their linear range, reproducibility, subtype detection, and agreement. A panel of HCV RNA samples ranging in nominal concentration from 1.0 to 7.0 log10 IU/ml was constructed by diluting a clinical specimen (genotype 1b). Replicates of the panel were tested in multiple laboratories using the Abbott TaqMan analyte-specific reagent (Abbott reverse transcription-PCR [RT-PCR]), Roche TaqMan RUO (Roche...

  15. Amperometric Biosensors for Real Time Assays of Organophosphates

    Directory of Open Access Journals (Sweden)

    Kamil Kuca

    2008-09-01

    Full Text Available An amperometric biosensor based on acetylcholinesterase (AChE immobilized in gelatin was used to develop an assay for the organophosphate paraoxon. The more traditional manner employing preincubation was used for comparison between measurement procedures, although the aim of the study was to examine the performance of the biosensor for real time monitoring of organophosphates. The biosensor was immersed in a reaction chamber and paraoxon was injected inside. We were able to detect 200 pg of paraoxon within one minute or 2.5 ppb when the biosensor was preincubed in the sample solution for 15 minutes. The practical impact and expectations are discussed.

  16. Larval feeding inhibition assay – need for optimisation

    DEFF Research Database (Denmark)

    Azuhnwi, Blasius; Desrues, O.; Hoste, H.;

    2013-01-01

    Data inconsistencies have been reported with the larval feeding inhibition assay (LFIA), an in vitro parasitological technique which measures the reduction of food ingestion by first stage larvae (L1) incubated in serial dilutions of a test substance. Possible factors that can account for this...... the erratic larval feeding in some concentrations. Negative controls varied (43-83 %) in their feeding activity whereas positive controls mostly resulted in almost complete (97-100 %) feeding inhibition. The EC50 values obtained for incubating larvae in sainfoin extract over the 4 week period ranged...

  17. On the efficiency calibration of a drum waste assay system

    CERN Document Server

    Dinescu, L; Cazan, I L; Macrin, R; Caragheorgheopol, G; Rotarescu, G

    2002-01-01

    The efficiency calibration of a gamma spectroscopy waste assay system, constructed by IFIN-HH, was performed. The calibration technique was based on the assumption of a uniform distribution of the source activity in the drum and also a uniform sample matrix. A collimated detector (HPGe--20% relative efficiency) placed at 30 cm from the drum was used. The detection limit for sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co is approximately 45 Bq/kg for a sample of about 400 kg and a counting time of 10 min. A total measurement uncertainty of -70% to +40% was estimated.

  18. Identification of Erwinia stewartii by a ligase chain reaction assay.

    OpenAIRE

    Wilson, W.J.; Wiedmann, M; Dillard, H. R.; Batt, C A

    1994-01-01

    A PCR-coupled ligase chain reaction (LCR) assay was developed to distinguish the plant pathogenic bacterium Erwinia stewartii from other erwiniae. This new technique allows discrimination to the species level on the basis of a single-base-pair difference in the 16S rRNA gene which is unique to E. stewartii. Portions of the 16S rRNA genes of E. stewartii and the closely related Erwinia herbicola were sequenced. From comparison of the two 16S rRNA gene regions, two primer pairs were constructed...

  19. Automated conductimetric assay of human serum cholinesterase activity.

    Science.gov (United States)

    Duffy, P; Wallach, J M

    1989-01-01

    Serum cholinesterase activity was determined by conductimetry using samples in the microliter range. Butyrylcholine iodide was demonstrated to be a convenient substrate for the conductimetric assay. Validation of the microassay was made by using either purified enzyme or control serum. In the range of 0-60 U/l, a linear relationship was demonstrated. Correlation with a reference spectrophotometric method was obtained with a slope of 1.18. An explanation of this value is proposed, as different hydrolysis rates were obtained with human sera, depending on the substrate used (butyrylthio- or butyryl-choline ester).

  20. Assay of the deuterium enrichment of water via acetylene.

    Science.gov (United States)

    Previs, S F; Hazey, J W; Diraison, F; Beylot, M; David, F; Brunengraber, H

    1996-06-01

    A technique is presented for measuring the 2H enrichment of water in biological samples when this enrichment is greater than 0.2%. The sample is reacted with calcium carbide to form acetylene gas, which is determined by gas chromatography electron impact ionization mass spectrometry. Ion-molecule reactions, resulting in proton abstraction, are minimized by lowering the electron ionization energy from the usual 70 eV to 45 eV. This technique is much more rapid and economical than the classical isotope ratio mass spectrometric assay of the enrichment of hydrogen gas derived from reduction of water.