WorldWideScience

Sample records for aortic balloon pump

  1. Predictors of cardiogenic shock in cardiac surgery patients receiving intra-aortic balloon pumps.

    Science.gov (United States)

    Iyengar, Amit; Kwon, Oh Jin; Bailey, Katherine L; Ashfaq, Adeel; Abdelkarim, Ayman; Shemin, Richard J; Benharash, Peyman

    2018-02-01

    Cardiogenic shock after cardiac surgery leads to severely increased mortality. Intra-aortic balloon pumps may be used during the preoperative period to increase coronary perfusion. The purpose of this study was to characterize predictors of postoperative cardiogenic shock in cardiac surgery patients with and without intra-aortic balloon pumps support. We performed a retrospective analysis of our institutional database of the Society of Thoracic Surgeons for patients operated between January 2008 to July 2015. Multivariable logistic regression was used to model postoperative cardiogenic shock in both the intra-aortic balloon pumps and matched control cohorts. Overall, 4,741 cardiac surgery patients were identified during the study period, of whom 192 (4%) received a preoperative intra-aortic balloon pump. Intra-aortic balloon pumps patients had a greater prevalence of diabetes, previous cardiac surgery, congestive heart failure, and an urgent/emergent status (P pumps patients also had greater 30-day mortality and more postoperative cardiogenic shock (9% vs 3%, P pumps cohort, only sex, previous percutaneous coronary intervention and preoperative arrhythmia remained significant on multivariable analysis (all P pumps and those who do not. Further analysis of the effects of prophylactic intra-aortic balloon pumps support is warranted. (Surgery 2017;160:XXX-XXX.). Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Intra Aortic Balloon Pump (IABP: Past, Present and Future

    Directory of Open Access Journals (Sweden)

    Jatin D Dedhia

    2008-01-01

    Full Text Available Intra Aortic Balloon Pump (IABP is the most commonly used mechanical circulatory assist device in cardiac patients. IABP can improve ventricular function by decreasing the preload and increasing systolic output with signifi-cant improvement in myocardial oxygen supply/demand ratio. Pre-operative IABP therapy in ′high-risk′ coronary patients has been shown to reduce hospital mortality and shorten ICU stay significantly, compared with controls. The introduction of sheathless insertion kits has reduced the incidence of vascular complication rates. Pro-Active Counter Pulsation is a new IABP system which automatically detects the irregular pattern and result is an improvement in the haemodynamic effect of IABP during periods of arrhythmia. Today, continued improvements in IABP technology permit safer use and earlier intervention to provide haemodynamic support. These developments have made the IABP a mainstay in the management of ischemic and dysfunctional myocardium. This review article aims to provide basic concept of IABP to hospital doctors especially anaesthetists, intensivists cardiologists and cardiac surgeons. It discusses the common indications, contraindications, the physiologic aspects of IABP, the equipment needed to facilitate IABP, the use of the IABP in special situations and complications of its use.

  3. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    Science.gov (United States)

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  4. Virtual 5-French intra-aortic pumping using a Glidesheath Slender and 6-French intra-aortic balloon catheter

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: a-takahashi@wine.ocn.ne.jp; Taniguchi, Norimasa; Mizuguchi, Yukio; Yamada, Takeshi; Nakajima, Shunsuke; Hashimoto, Sho; Hata, Tetsuya

    2015-07-15

    Objectives: The aim of this study was to evaluate the feasibility and safety of the 6-Fr Glidesheath Slender, which has equivalent outer size to the conventional 5-Fr sheath, for use with the 6-Fr intra-aortic balloon pump (IABP) catheter. Methods: Between May 2014 and March 2015, 24 patients with acute coronary syndrome underwent percutaneous coronary intervention using a 6-Fr IABP catheter through a 6-Fr Glidesheath Slender for support. The adverse events, including access site complications, kinking of the sheath during the procedure, and any evidence of balloon pump failure, were retrospectively investigated. Results: Insertion of the IABP catheter through either the femoral or brachial artery was successful in all patients. The mean support time was 32.4 ± 22.0 h. No major hemorrhagic event or severe limb ischemia was observed. Kinking of the shaft occurred during insertion in one patient; however, the subsequent balloon pumping was well maintained and did not require exchange of the sheath or IABP catheter. No kind of IABP failure was observed. Conclusion: Although this sheath was originally designed to allow radial access, our results suggest that the use of the Glidesheath Slender is feasible for insertion of the 6-Fr IABP catheter through the brachial and femoral arteries, and may reduce vascular complications in patients who undergo percutaneous coronary intervention.

  5. Stimulus-response time to alarms of the intra-aortic balloon pump: safe care practices

    Directory of Open Access Journals (Sweden)

    Andrezza Serpa Franco

    Full Text Available ABSTRACT Objective: To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. Method: This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. Results: The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. Conclusion: Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology.

  6. The management of impending myocardial infarction using coronary artery by-pass grafting and an intra-aortic balloon pump.

    Science.gov (United States)

    Harris, P L; Woollard, K; Bartoli, A; Makey, A R

    1980-01-01

    Of 33 patients with impending myocardial infarction 25 were treated using a combination of coronary artery by-pass grafting and intra-aortic balloon pumping. Eight patients were treated with coronary artery by-pass grafting alone. Twenty-two of the 25 patients who were treated with the combined technique made a full recovery. Three patients sustained definite myocardial infarctions and one of these died. Five of the 8 patients treated by grafting alone suffered infarction and of these 3 died. The value of intra-aortic balloon pumping in combination with coronary artery by-pass grafting in the management of impending myocardial infarction is discussed.

  7. Usefulness of intra-aortic balloon pump counterpulsation in patients with cardiogenic shock from acute myocardial infarction

    NARCIS (Netherlands)

    Cheng, Jin M.; Valk, Suzanne D. A.; den Uil, Corstiaan A.; van der Ent, Martin; Lagrand, Wim K.; van de Sande, Meike; van Domburg, Ron T.; Simoons, Maarten L.

    2009-01-01

    Although intra-aortic balloon pump (IABP) counterpulsation is increasingly being used for the treatment of patients with cardiogenic shock from acute myocardial infarction, data on the long-term outcomes are lacking. The aim of the present study was to evaluate the 30-day and long-term mortality and

  8. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous

    NARCIS (Netherlands)

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N.; Pijls, Nico H. J.; de Mol, Bas A.; Rutten, Marcel C. M.

    2011-01-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in

  9. Benefits of ambulatory axillary intra-aortic balloon pump for circulatory support as bridge to heart transplant.

    Science.gov (United States)

    Umakanthan, Ramanan; Hoff, Steven J; Solenkova, Natalia; Wigger, Mark A; Keebler, Mary E; Lenneman, Andrew; Leacche, Marzia; Disalvo, Thomas G; Ooi, Henry; Naftilan, Allen J; Byrne, John G; Ahmad, Rashid M

    2012-05-01

    Axillary intra-aortic balloon pump therapy has been described as a bridge to transplant. Advantages over femoral intra-aortic balloon pump therapy include reduced incidence of infection and enhanced patient mobility. We identified the patients who would benefit most from this therapy while awaiting heart transplantation. We conducted a single-center, retrospective observational study to evaluate outcomes from axillary intra-aortic balloon pump therapy. These included hemodynamic parameters, duration of support, and success in bridging to transplant. We selected patients on the basis of history of sternotomy, elevated panel-reactive antibody, and small body habitus. Patients were made to ambulate aggressively beginning on postoperative day 1. Between September 2007 and September 2010, 18 patients underwent axillary intra-aortic balloon pump therapy. All patients had the devices placed through the left axillary artery with a Hemashield side graft (Boston Scientific, Natick, Mass). Before axillary placement, patients underwent femoral placement to demonstrate hemodynamic benefit. Duration of support ranged from 5 to 63 days (median = 19 days). There was marked improvement in ambulatory potential and hemodynamic parameters, with minimal blood transfusion requirements. There were no device-related infections. Some 72% of the patients (13/18) were successfully bridged to transplantation. Axillary intra-aortic balloon pump therapy provides excellent support for selected patients as a bridge to transplant. The majority of the patients were successfully bridged to transplant and discharged. Although this therapy has been described in previous studies, this is the largest series to incorporate a regimen of aggressive ambulation with daily measurements of distances walked. Copyright © 2012. Published by Mosby, Inc.

  10. In reply to: "Intra-aortic balloon pump protects against hydrostatic pulmonary oedema during peripheral venoarterial-extracorporeal membrane oxygenation".

    Science.gov (United States)

    Privratsky, Jamie R; Diaz, Sebastian; Nicoara, Alina; Daneshmand, Mani A

    2018-05-01

    Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is an increasingly utilized life-saving measure. However, left-ventricular distention from inadequate left-ventricular off-loading can lead to unwanted pulmonary and cardiac complications. We are writing to indicate our agreement with a recent article by Brechot et al. published in the June 2017 issue where the authors demonstrated that intra-aortic balloon pump provides mechanical support to off-load the left ventricle during VA-ECMO, which prevents pulmonary edema.

  11. Cardiopulmonary bypass and intra-aortic balloon pump use is associated with higher short and long term mortality after transcatheter aortic valve replacement: a PARTNER trial substudy.

    Science.gov (United States)

    Shreenivas, Satya S; Lilly, Scott M; Szeto, Wilson Y; Desai, Nimesh; Anwaruddin, Saif; Bavaria, Joseph E; Hudock, Kristin M; Thourani, Vinod H; Makkar, Raj; Pichard, Augusto; Webb, John; Dewey, Todd; Kapadia, Samir; Suri, Rakesh M; Xu, Ke; Leon, Martin B; Herrmann, Howard C

    2015-08-01

    Transcatheter aortic valve replacement (TAVR) with the balloon-expandable Sapien transcatheter heart valve improves survival compared to standard therapy in patients with severe aortic stenosis (AS) and is noninferior to surgical aortic valve replacement (AVR) in patients at high operative risk. Nonetheless, a significant proportion of patients may require pre-emptive or emergent support with cardiopulmonary bypass (CPB) and/or intra-aortic balloon pump (IABP) during TAVR due to pre-existing comorbid conditions or as a result of procedural complications. We hypothesized that patients who required CPB or IABP would have increased periprocedural complications and reduced long-term survival. In addition, we sought to determine whether preprocedural variables could predict the need for CPB and IABP. The study population included 2,525 patients in the PARTNER Trial (Cohort A and B) and the continuing access registry (CAR). Patients that received CPB or IABP were compared to patients that did not receive either, and then further divided into those that received support pre-TAVR and those that were placed on support emergently. One-hundred sixty-three patients (6.5%) were placed on CPB and/or IABP. The use of CPB or IABP was associated with higher 1 year mortality (49.1% vs. 21.6%, P non-CPB/IABP cases (53.3% and 40.3% vs. 21.6%, P < 0.001). These findings indicate that CPB and IABP use in TAVR portends a poor prognosis and its utilization, particularly in the setting of pre-emptive use, needs reconsideration. © 2015 Wiley Periodicals, Inc.

  12. The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome.

    LENUS (Irish Health Repository)

    Parissis, Haralabos

    2010-01-01

    BACKGROUND: The early and intermediate outcome of patients requiring intraaortic balloon pump (IABP) was studied in a cohort of 2697 adult cardiac surgical patients. METHODS: 136 patients requiring IABP (5.04%) support analysed over a 4 year period. Prospective data collection, obtained. RESULTS: The overall operative mortality was 35.3%. The "operation specific" mortality was higher on the Valve population.The mortality (%) as per time of balloon insertion was: Preoperative 18.2, Intraoperative 33.3, postoperative 58.3 (p < 0.05).The incremental risk factors for death were: Female gender (Odds Ratio (OR) = 3.87 with Confidence Intervals (CI) = 1.3-11.6), Smoking (OR = 4.88, CI = 1.23- 19.37), Preoperative Creatinine>120 (OR = 3.3, CI = 1.14-9.7), Cross Clamp time>80 min (OR = 4.16, CI = 1.73-9.98) and IABP insertion postoperatively (OR = 19.19, CI = 3.16-116.47).The incremental risk factors for the development of complications were: Poor EF (OR = 3.16, CI = 0.87-11.52), Euroscore >7 (OR = 2.99, CI = 1.14-7.88), history of PVD (OR = 4.99, CI = 1.32-18.86).The 5 years survival was 79.2% for the CABG population and 71.5% for the valve group. (Hazard ratio = 1.78, CI = 0.92-3.46). CONCLUSIONS: IABP represents a safe option of supporting the failing heart. The need for IABP especially in a high risk Valve population is associated with early unfavourable outcome, however the positive mid term results further justify its use.

  13. The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome

    Directory of Open Access Journals (Sweden)

    Apostolakis Efstratios

    2010-04-01

    Full Text Available Abstract Background The early and intermediate outcome of patients requiring intraaortic balloon pump (IABP was studied in a cohort of 2697 adult cardiac surgical patients. Methods 136 patients requiring IABP (5.04% support analysed over a 4 year period. Prospective data collection, obtained. Results The overall operative mortality was 35.3%. The "operation specific" mortality was higher on the Valve population. The mortality (% as per time of balloon insertion was: Preoperative 18.2, Intraopeartive 33.3, postoperative 58.3 (p The incremental risk factors for death were: Female gender (Odds Ratio (OR = 3.87 with Confidence Intervals (CI = 1.3-11.6, Smoking (OR = 4.88, CI = 1.23- 19.37, Preoperative Creatinine>120 (OR = 3.3, CI = 1.14-9.7, Cross Clamp time>80 min (OR = 4.16, CI = 1.73-9.98 and IABP insertion postoperatively (OR = 19.19, CI = 3.16-116.47. The incremental risk factors for the development of complications were: Poor EF (OR = 3.16, CI = 0.87-11.52, Euroscore >7 (OR = 2.99, CI = 1.14-7.88, history of PVD (OR = 4.99, CI = 1.32-18.86. The 5 years survival was 79.2% for the CABG population and 71.5% for the valve group. (Hazard ratio = 1.78, CI = 0.92-3.46. Conclusions IABP represents a safe option of supporting the failing heart. The need for IABP especially in a high risk Valve population is associated with early unfavourable outcome, however the positive mid term results further justify its use.

  14. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.

    Science.gov (United States)

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N; Pijls, Nico H J; de Mol, Bas A; Rutten, Marcel C M

    2011-09-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support

  15. Preoperative optimization of multi-organ failure following acute myocardial infarction and ischemic mitral regurgitation by placement of a transthoracic intra-aortic balloon pump.

    Science.gov (United States)

    Umakanthan, Ramanan; Dubose, Robert; Byrne, John G; Ahmad, Rashid M

    2010-10-01

    The management of acute myocardial infarction with resultant acute ischemic mitral regurgitation and acute multi-organ failure can prove to be a very challenging scenario. The presence of concomitant vascular disease can only serve to further compromise the complexity of the situation. We demonstrate a new indication for the transthoracic intra-aortic balloon pump as a preoperative means of unloading the heart and improving clinical outcome in such high-risk patients with severe vascular disease. We present the case of a 75-year-old man with a history of severe vascular disease who was transferred emergently to Vanderbilt University Medical Center with an acute inferolateral wall myocardial infarction resulting in severe acute ischemic mitral regurgitation and acute multi-organ failure. He presented with shock liver (serum glutamic-oxaloacetic transaminase [SGOT] of 958), renal failure (creatinine of 3.0), and respiratory failure with a pH of 7.18. Emergent cardiac catheterization revealed 100% occlusion of the left circumflex artery as well as severe ileofemoral disease. The advanced nature of his ileofemoral disease was such that the arterial access catheter occluded the right femoral artery. The duration of time that the catheter was in the artery led to transient limb ischemia with an elevation of his creatine phosphokinase (CPK) to 10,809. Balloon angioplasty followed by stent placement was successfully performed, which restored flow to the coronary vessel. Given the grave nature of the patient's condition, we were very concerned that immediate operative intervention for his condition would entail prohibitively high risk. In fact, the Society of Thoracic Surgeons predicted risk adjusted mortality was calculated to be 56%. In order to minimize patient mortality and morbidity, it was critical to help restore perfusion and organ recovery. Therefore, we decided that the chances for this patient's survival would improve if his condition could be optimized by

  16. Clinical and hemodynamic effects of intra-aortic balloon pump therapy in chronic heart failure patients with cardiogenic shock.

    Science.gov (United States)

    Fried, Justin A; Nair, Abhinav; Takeda, Koji; Clerkin, Kevin; Topkara, Veli K; Masoumi, Amirali; Yuzefpolskaya, Melana; Takayama, Hiroo; Naka, Yoshifumi; Burkhoff, Daniel; Kirtane, Ajay; Dimitrios Karmpaliotis, S M; Moses, Jeffrey; Colombo, Paolo C; Garan, A Reshad

    2018-03-20

    The role of the intra-aortic balloon pump (IABP) in acute decompensated heart failure (HF) with cardiogenic shock (CS) is largely undefined. In this study we sought to assess the hemodynamic and clinical response to IABP in chronic HF patients with CS and identify predictors of response to this device. We retrospectively reviewed all patients undergoing IABP implantation from 2011 to 2016 at our institution to identify chronic HF patients with acute decompensation and CS (cardiac index <2.2 liters/min/m 2 and systolic blood pressure <90 mm Hg or need for vasoactive medications to maintain this level). Clinical deterioration on IABP was defined as failure to bridge to either discharge on medical therapy or durable heart replacement therapy (HRT; durable left ventricular assist device or heart transplant) with IABP alone. We identified 132 chronic HF patients with IABP placed after decompensation with hemodynamic evidence of CS. Overall 30-day survival was 84.1%, and 78.0% of patients were successfully bridged to HRT or discharge without need for escalation of device support. The complication rate during IABP support was 2.3%. Multivariable analysis identified ischemic cardiomyopathy (odds ratio [OR] 3.24, 95% confidence interval [CI] 1.16 to 9.06; p = 0.03) and pulmonary artery pulsatility index (PAPi) <2.0 (OR 5.04, 95% CI 1.86 to 13.63; p = 0.001) as predictors of clinical deterioration on IABP. Overall outcomes with IABP in acute decompensated chronic HF patients are encouraging, and IABP is a reasonable first-line device for chronic HF patients with CS. Baseline right ventricular function, as measured by PAPi, is a major predictor of outcomes with IABP in this population. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  17. Inflation and deflation timing of the AutoCAT 2 WAVE intra-aortic balloon pump using the autoPilot mode in a clinical setting.

    Science.gov (United States)

    Bakker, E W M; Visser, K; van der Wal, A; Kuiper, M A; Koopmans, M; Breedveld, R

    2012-09-01

    The primary goal of this observational clinical study was to register the occurrence of incorrect inflation and deflation timing of an intra-aortic balloon pump in autoPilot mode. The secondary goal was to identify possible causes of incorrect timing. During IABP assistance of 60 patients, every four hours a strip was printed with the IABP frequency set to 1:2. Strips were examined for timing discrepancies beyond 40 ms from the dicrotic notch (inflation) and the end of the diastolic phase (deflation). In this way, 320 printed strips were examined. A total of 52 strips (16%) showed incorrect timing. On 24 of these strips, the incorrect timing was called incidental, as it showed on only one or a few beats. The other 28 cases of erroneous timing were called consistent, as more than 50% of the beats on the strip showed incorrect timing. We observed arrhythmia in 69% of all cases of incorrect timing. When timing was correct, arrhythmia was found on 13 (5%) of 268 strips. A poor quality electrocardiograph (ECG) signal showed on 37% of all strips with incorrect timing and 11% of all strips with proper timing. We conclude that inflation and deflation timing of the IABP is not always correct when using the autoPilot mode. The quality of the ECG input signal and the occurrence of arrhythmia appear to be related to erroneous timing. Switching from autoPilot mode to operator mode may not always prevent incorrect timing.

  18. Factors associated with pulmonary dysfunction in patients undergoing coronary artery bypass graft surgery with use of intra-aortic balloon pump.

    Science.gov (United States)

    Amaral Gonçalves Fusatto, Helena; Castilho de Figueiredo, Luciana; Ragonete Dos Anjos Agostini, Ana Paula; Sibinelli, Melissa; Dragosavac, Desanka

    2018-01-01

    The aim of this study was to identify pulmonary dysfunction and factors associated with prolonged mechanical ventilation, hospital stay, weaning failure and mortality in patients undergoing coronary artery bypass grafting with use of intra-aortic balloon pump (IABP). This observational study analyzed respiratory, surgical, clinical and demographic variables and related them to outcomes. We analyzed 39 patients with a mean age of 61.2 years. Pulmonary dysfunction, characterized by mildly impaired gas exchange, was present from the immediate postoperative period to the third postoperative day. Mechanical ventilation time was influenced by the use of IABP and PaO2/FiO2, female gender and smoking. Intensive care unit (ICU) stay was influenced by APACHE II score and use of IABP. Mortality was strongly influenced by APACHE II score, followed by weaning failure. Pulmonary dysfunction was present from the first to the third postoperative day. Mechanical ventilation time was influenced by female gender, smoking, duration of IABP use and PaO2/FiO2 on the first postoperative day. ICU stay was influenced by APACHE II score and duration of IABP. Mortality was influenced by APACHE II score, followed by weaning failure. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Aortic valvuloplasty of calcific aortic stenosis with monofoil and trefoil balloon catheters: practical considerations

    NARCIS (Netherlands)

    S. Plante (Sylvain); M.J.B.M. van den Brand (Marcel); L.C.P. van Veen; C. di Mario (Carlo); C.E. Essed; K.J. Beatt (Kevin); P.W.J.C. Serruys (Patrick)

    1990-01-01

    textabstractIn order to evaluate the relation between balloon design (monofoil, trefoil) and valvular configuration, experimental aortic valvuloplasty was performed in four post-mortem hearts with calcific aortic stenosis of various morphology. The degree of obstruction of the aortic orifice was

  20. The outcomes of intra-aortic balloon pump usage in patients with acute myocardial infarction: a comprehensive meta-analysis of 33 clinical trials and 18,889 patients

    Directory of Open Access Journals (Sweden)

    Fan ZG

    2016-03-01

    Full Text Available Zhong-Guo Fan,1,* Xiao-Fei Gao,1,2,* Li-Wen Chen,1 Xiao-Bo Li,1,2 Ming-Xue Shao,1,2 Qian Ji,1 Hao Zhu,1 Yi-Zhi Ren,1 Shao-Liang Chen,1,2 Nai-Liang Tian1,2 1Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, 2Department of Cardiology, Nanjing Heart Center, Nanjing, People’s Republic of China *These authors contributed equally to this work Background: The effects of intra-aortic balloon pump (IABP usage in patients with acute myocardial infarction remain controversial. This study sought to evaluate the outcomes of IABP usage in these patients.Methods: Medline, EMBASE, and other internet sources were searched for relevant clinical trials. The primary efficacy endpoints (in-hospital, midterm, and long-term mortality and secondary endpoints (reinfarction, recurrent ischemia, and new heart failure in the hospital as well as safety endpoints (severe bleeding requiring blood transfusion and stroke in-hospital were subsequently analyzed.Results: Thirty-three clinical trials involving 18,889 patients were identified. The risk of long-term mortality in patients suffering from acute myocardial infarction was significantly decreased following IABP use (odds ratio [OR] 0.66, 95% confidence interval [CI]: 0.48–0.91, P=0.010. Both in-hospital and midterm mortality did not differ significantly between the IABP use group and no IABP use group (in-hospital: OR 0.87, 95% CI: 0.59–1.28, P=0.479; midterm: OR 1.12, 95% CI: 0.53–2.38, P=0.768. IABP insertion was not associated with the risk reduction of reinfarction, recurrent ischemia, or new heart failure. However, IABP use increased the risk of severe bleeding requiring blood transfusion (OR 2.05, 95% CI: 1.29–3.25, P=0.002 and stroke (OR 1.71, 95% CI: 1.04–2.82, P=0.035. In the thrombolytic therapy and cardiogenic shock subgroups, reduced mortality rates following IABP use were observed.Conclusion: IABP insertion is associated with feasible benefits with respect to long

  1. Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation

    Science.gov (United States)

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R.

    2015-01-01

    Abstract The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. PMID:25959284

  2. Measurements of Intra-Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation.

    Science.gov (United States)

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R; Khir, Ashraf W

    2015-08-01

    The intra-aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre-, intra-, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi-recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra-aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. Copyright © 2015 The Authors. Artificial Organs published by Wiley Periodicals, Inc. on behalf of International Center for

  3. Pulmonary Venous Diastolic Flow Reversal and Flash Pulmonary Edema During Management of Ongoing Myocardial Ischemia with Intraaortic Balloon Pump.

    Science.gov (United States)

    Murray, Davoy; Peng, Yong G

    2015-10-15

    A 65-year-old man was admitted for acute coronary syndrome with depressed left ventricular function and moderate aortic regurgitation. He was managed with an intraaortic balloon pump for circulatory support before coronary artery bypass grafting and subsequently developed flash pulmonary edema with an associated rare finding of diastolic pulmonary venous flow reversal. In this report, we provide a review of intraaortic balloon pump use in current clinical practice and elaborate on the pathophysiology of an uncommon pulmonary venous flow pattern found in our patient.

  4. Physiologic Tolerance of Descending Thoracic Aortic Balloon Occlusion in a Swine Model of Hemorrhagic Shock

    Science.gov (United States)

    2013-01-10

    Endovascular proximal control of ruptured abdominal aortic aneurysms: the internal aortic clamp. J Cardiovasc Surg (Torino) 2009;50(3):381. 14. Arthurs Z...Starnes B, See C, Andersen C. Clamp Before You Cut: Proximal Control of Ruptured Abdominal Aortic Aneurysms Using Endovascular Balloon Occlusion

  5. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    International Nuclear Information System (INIS)

    Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan

    2015-01-01

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification

  6. Isothermal pumping analysis for high-altitude tethered balloons.

    Science.gov (United States)

    Kuo, Kirsty A; Hunt, Hugh E M

    2015-06-01

    High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal analysis is used to determine the variation of pressures and velocities along the pipe length. Results show that transport of small quantities of hydrogen to power fuel cells and maintain balloon buoyancy can be achieved at pressures and temperatures that are tolerable in terms of both the pipe strength and the current state of pumping technologies. To avoid solidification, transport of SO2 would require elevated temperatures that cannot be tolerated by the strength fibres in the pipe. While the use of particle-based slurries rather than SO2 for climate engineering can reduce the pipe size significantly, the pumping pressures are close to the maximum bursting pressure of the pipe.

  7. Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Anupama Shivaraju

    2018-01-01

    Full Text Available Objectives. The aim of this study is to assess the feasibility and clinical outcome of transcatheter aortic valve replacement (TAVR using aortic valve predilatation (AVPD with a small, nonocclusive balloon. Background. Balloon aortic valvuloplasty (BAV under rapid pacing is generally performed in TAVR to ensure the passage and sufficient deployment of the prosthesis in the stenotic AV. BAV may cause serious complications, such as left ventricular stunning or cerebrovascular embolism. Methods. A cohort of 50 consecutive patients with severe aortic stenosis underwent transfemoral TAVR with the Edwards Sapien 3-heart valve. All patients underwent AVPD with a small, nonocclusive balloon (12 × 60 or 14 × 60 mm without rapid pacing. Procedural data and clinical outcomes were analyzed. Results. The mean age of the cohort was 81±6 years and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation was 13±9. Crossing the AV and prosthesis implantation was successful in all cases. The postprocedural mean AV gradient was 12±5 mmHg. There were no cases of aortic regurgitation ≥ grade 2. No periprocedural stroke occurred. One patient (2% with chronic atrial fibrillation displayed a transient Wernicke aphasia occurring more than 24 hours after TAVR. Mortality was 0% at 30 days after procedure. Conclusion. In TAVR, AVPD with a small, nonocclusive balloon can be safely performed. By avoiding rapid pacing, this technique may be a valid alternative to traditional BAV. Whether or not the use of APVD without rapid pacing translates into less periprocedural complications needs to be assessed in future studies.

  8. Radionuclide assessment of left ventricular function in patients requiring intraoperative balloon pump assistance

    International Nuclear Information System (INIS)

    Davies, R.A.; Laks, H.; Wackers, F.J.; Berger, H.J.; Williams, B.; Hammond, G.L.; Geha, A.S.; Gottschalk, A.; Zaret, B.L.

    1982-01-01

    Twenty-three surviving patients who were weaned from cardiopulmonary bypass with intraaortic balloon pump assistance returned for follow-up radionuclide left ventricular (LV) function and thallium 201 perfusion studies at a mean of 23 +/- 3 months following operation. It was found that despite profound intraoperative myocardial depression requiring intraaortic balloon assistance, 13 patients had no change (within 10%) in the resting LV ejection fraction compared with the preoperative measurement. Among all 23 patients, there was no difference between mean (+/- standard error of the mean) preoperative and postoperative resting LV ejection fraction (48 +/- 4 vs 46 +/- 4%, p . not significant [NS]). Only 11 patients had perioperative myocardial infarction documented by new Q waves in the electrocardiogram, by elevation of creatine kinase-MB fraction, or by defects on thallium 201 imaging not explained by documented myocardial infarction before operation. Overall, postoperative resting LV ejection fraction was not different from the preoperative value in patients with perioperative myocardial infarction (44 +/- 7 vs 47 +/- 5%, p . NS). Postoperative resting LV ejection fraction rose by greater than 10% compared with preoperative values in 4 patients (3 with aortic valve replacement), remained within the 10% limit in 9 patients, and fell by greater than 10% in 10 patients (7 with perioperative myocardial infarction). Only 4 out of 16 patients studied at follow-up with exercise radionuclide studies demonstrated a normal LV response to exercise (greater than 5% increase in LV ejection fraction). Thus, among survivors requiring intraaortic balloon pump assistance for weaning from cardiopulmonary bypass, LV performance at rest is frequently preserved. In addition, 11 of the 23 patients had evidence of perioperative myocardial infarction, indicating a component of reversible intraoperative LV dysfunction

  9. Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2009-06-01

    ão.OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning

  10. 78 FR 79300 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems for Acute...

    Science.gov (United States)

    2013-12-30

    .... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems... of these devices into class II. List of Subjects in 21 CFR Part 870 Medical devices, Cardiovascular... Commissioner of Food and Drugs, 21 CFR part 870 is amended as follows: PART 870--CARDIOVASCULAR DEVICES 0 1...

  11. 78 FR 36702 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems (IABP) for...

    Science.gov (United States)

    2013-06-19

    .... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems... Device In the preamble to the proposed rule (44 FR 13369; March 9, 1979), the Cardiovascular Device... Bypass Grafting: A Propensity Score Analysis,'' Interactive Cardiovascular and Thoracic Surgery, vol. 9...

  12. Fiber-optic intra-aortic balloon therapy and its role within cardiac surgery.

    Science.gov (United States)

    Yarham, G; Clements, A; Morris, C; Cumberland, T; Bryan, M; Oliver, M; Burrows, H; Mulholland, J

    2013-03-01

    The patient population has changed and the cardiothoracic team are now operating on patients with more co-morbidity. One of the significant aspects of this increased co-morbidity, which affects both short- and long-term outcomes, is compromised left ventricular function. Intra-aortic balloon pump (IABP) technology offers these patients and the cardiac team an easily accessible, cost-effective, mechanical assist device. Arterial pressure monitoring for IABP therapy: Fluid-filled transducers used to measure the aortic waveform can be unreliable and inconsistent. Fiber-optic manometers located in the very tip of the IAB catheters provide accurate and fast, high quality measurements. This, in turn, presents the opportunity for the hardware and algorithm to measure key markers on the arterial waveform and optimise left ventricular support. It also provides the potential for automatic in vivo calibration, further increasing the accuracy and quality of the IAB support. The effect of fiber-optic IABP therapy on clinical management: A dual centre prospective audit comparing fluid-filled versus fiber-optic arterial pressure monitoring showed a 96% reduction in IAB-related perfusion on-site call-outs (17 vs. 1, respectively) and a 94% reduction in sub-optimal timing (55/98 vs. 2/94, respectively). The improved timing algorithms utilise the pressure information received 50 msecs faster than with fluid-filled transducers, measuring key markers on the pressure waveform and adjusting inflation and deflation accurately on a beat per beat basis. Fiber-optic IAB technology and, specifically, these improved algorithms provide better beat per beat mechanical support. Given our evolving patient population, this technology will not only play an increased role, but will have a significant impact on cardiac surgery.

  13. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    Science.gov (United States)

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  14. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    International Nuclear Information System (INIS)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki; Ohishi, Sonomi; Nojiri, Yoko; Ogata, Hitoshi

    2001-01-01

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source

  15. Immediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting

    Directory of Open Access Journals (Sweden)

    Hasan Mottaghi Moghadam

    2017-12-01

    Full Text Available Background Aortic Coarcatation (CoA is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs. Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA. We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty with our without stenting was performed for 53 patients with native or Re-coarcatation angioplasty (39 balloon angioplasty alone, and 14 balloon and stenting. Pressure gradient across the CoA segment was measured initially by Echo and pre, and Post procedure. Echocardiography was also used for follow up assessment during 24 hours, one and 6 months afterward. Results Among 53 patients, 52.8% were male. There were 98.2% native and 3.8% Re-CoA. The mean age of patients was 8.65 ± 8.37 years, and the mean weight was 25.82±20.73 kg. The mean pressure gradient acrossthe CoA site before angioplasty was 24.88±12.32, and post procedure gradient was 4.77±6.42 (p

  16. Uso rutinario del balón de contra-pulsación aórtica preoperatorio en pacientes con enfermedad del tronco común izquierdo sometidos a cirugía de revascularización coronaria Routine use of preoperative intra-aortic balloon pump counterpulsation (IABP implantation in patients with left main coronary artery disease undergoing coronary revascularization surgery

    Directory of Open Access Journals (Sweden)

    Andrés Fernández

    2008-08-01

    cuidados intensivos se infectaron 6,5% de los pacientes con balón y 3% del grupo sin balón (p=0,49 y hubo sepsis en 4,3% del grupo con balón y en ninguno del grupo restante (p=0,23. La letalidad en la unidad de cuidados intensivos se presentó en 2,2% del grupo de balón y en 3% del otro grupo (p=0,06. No ocurrió mortalidad intrahospitalaria fuera de la unidad de cuidados intensivos como tampoco mortalidad a 30 días después del alta. El tiempo de estancia en la misma unidad fue de 4,13 días en el grupo de balón y 2,7 días en el grupo sin balón, sin diferencia estadísticamente significativa entre éstos (p=0,154. El tiempo de ventilación mecánica en el grupo de balón fue de 1,96 días mientras que en el otro grupo fue de 1,18 días sin diferencia estadísticamente significativa (p=0,288. Con respecto a los pacientes que recibieron balón de contra pulsación intra-aórtico, el promedio de uso de balón fue de 1,32 días y no se presentaron complicaciones vasculares relacionadas con su uso. Conclusiones: este estudio sugiere que con el uso rutinario del balón de contra pulsación aórtica previo a la cirugía electiva de revascularización coronaria en pacientes cuya única indicación sea la lesión severa del tronco común izquierdo, no se obtiene beneficio en cuanto a letalidad y tiempo de estancia en la unidad de cuidados intensivos, ni con respecto al tiempo de ventilación mecánica. Tampoco se encontró mayor riesgo de desarrollar infección o sepsis en la misma unidad.Background: Left main coronary artery disease as the only criterion for intra-aortic balloon counterpulsation implantation is an indication which evidence is limited to experts’ recommendations; therefore, studies that may give a higher level of evidence are required. For this reason, we developed in our institution a study that evaluated the experience in the use of IABP in patients with left main coronary artery disease undergoing coronary revascularization surgery. Objective

  17. High-pressure balloon dilation in a dog with supravalvular aortic stenosis.

    Science.gov (United States)

    Pinkos, A; Stauthammer, C; Rittenberg, R; Barncord, K

    2017-02-01

    A 6-month-old female intact Goldendoodle was presented for diagnostic work up of a grade IV/VI left basilar systolic heart murmur. An echocardiogram was performed and revealed a ridge of tissue distal to the aortic valve leaflets at the sinotubular junction causing an instantaneous pressure gradient of 62 mmHg across the supravalvular aortic stenosis and moderate concentric hypertrophy of the left ventricle. Intervention with a high-pressure balloon dilation catheter was pursued and significantly decreased the pressure gradient to 34 mmHg. No complications were encountered. The patient returned in 5 months for re-evaluation and static long-term reduction in the pressure gradient was noted. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Australasian trends in intra-aortic balloon counterpulsation weaning: results of a postal survey.

    Science.gov (United States)

    Lewis, Peter A; Mullany, Daniel V; Courtney, Mary; Coyer, Fiona

    2006-12-01

    To generate baseline data describing Australasian intra-aortic balloon counterpulsation (IABP) weaning practice. A five-part questionnaire was mailed in April 2005 to all 192 intensive care units in Australia and New Zealand. 116 ICUs responded (response rate, 60%), and 54 reported using IABP. Most of the 54 were in hospitals which were public government-funded (65%), had between 100 and 500 beds (69%), and treated a minimum of 11 patients annually with IABP (60%). The most common method of withdrawing IABP support was ratio reduction alone (61%). ICUs most likely to undertake ratio weaning were higherend users of IABP (> 20 cases per annum) (P = 0.04). Other weaning practices involved a combination of ratio followed by volume reduction (17%), volume then ratio (11%), and volume only (4%). Approaching statistical significance, ratio reduction weaning less frequently required IABP reinsertion or inotropic increase after balloon removal (P = 0.07). ICUs with documented weaning policies were less likely to require IABP reinsertion or inotropic increase after balloon removal (P = 0.06). Criteria considered important before IABP weaning or removal were: blood pressure (92%); heart rate (76%); pulmonary artery wedge pressure (59%); noradrenaline dose (78%); adrenaline dose (57%); and dobutamine dose (57%). Ninety per cent of ICUs reported increasing inotropes after balloon removal only rarely (1:50 patients) or occasionally (1:10 patients), while 87% of ICUs reported never needing to reinsert the balloon or only rarely. The Australasian approach to IABP weaning is eclectic. While ratio reduction weaning appears the most successful manner of support withdrawal, it may be a consequence of a volume-outcome relationship, with high- end users achieving better results through IABP familiarity.

  19. Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome: Midterm outcomes and aortic remodeling.

    Science.gov (United States)

    Faure, Elsa Madeleine; El Batti, Salma; Abou Rjeili, Marwan; Ben Abdallah, Iannis; Julia, Pierre; Alsac, Jean-Marc

    2018-05-17

    The study objective was to assess the midterm outcomes and aortic remodeling in patients with Marfan syndrome with complicated acute type B aortic dissection treated with stent-assisted, balloon-induced intimal disruption and relamination. We reviewed all patients treated with stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection associated with Marfan syndrome according to the revised Ghent criteria. Between 2015 and November 2017, 7 patients with Marfan syndrome underwent stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection. The median age of patients was 47 years (range, 23-70). Four patients had a history of aortic root replacement. Technical success was achieved in 100%. Three patients required an adjunctive procedure for renal artery stenting (n = 2) and iliac artery stenting (n = 1). There was no in-hospital death, 30-day postoperative stroke, spinal cord ischemia, ischemic colitis, or renal failure requiring dialysis. At a median follow-up of 15 months (range, 7-28), 1 patient required aortic arch replacement for aneurysmal degeneration associated with a type Ia endoleak at 2 years, giving a late reintervention rate of 14%. There was no other secondary endoleak. The primary visceral patency rate was 100%. There were no all-cause deaths reported. At last computed tomography scan, all patients had complete aortic remodeling of the treated thoracoabdominal aorta. Distally, at the nonstented infrarenal aortoiliac level, 6 patients had persistent false lumen flow with stable aorto-iliac diameter in 5. One patient had iliac diameter growth (27 mm diameter at last computed tomography scan). Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome is feasible, safe, and associated with an immediate and midterm persisting thoracoabdominal aortic remodeling. Copyright

  20. Caesarean section combined with temporary aortic balloon occlusion followed by uterine artery embolisation for the management of placenta accreta

    International Nuclear Information System (INIS)

    Duan, X.-H.; Wang, Y.-L.; Han, X.-W.; Chen, Z.-M.; Chu, Q.-J.; Wang, L.; Hai, D.-D.

    2015-01-01

    Aim: To determine the efficacy and safety of caesarean section combined with temporary aortic balloon occlusion followed by uterine artery embolisation (UAE) for the treatment of patients with placenta accreta. Materials and methods: This retrospective study involved 42 patients with placenta accreta. All patients underwent caesarean section combined with temporary aortic balloon occlusion followed by UAE through the right femoral approach. Results: All patients were confirmed to have placenta praevia and accreta, including five patients with placenta percreta, at the time of delivery. The technical success rate of the combined treatment was 97.6% (41/42). Forty-one patients underwent successful caesarean section with conservation of the uterus. Hysterectomy was required in one (3.1%) patient. The amount of blood loss and blood transfusion, and the operation time were was 586 ± 355 ml, 422 ± 83 ml and 65.5 ± 10.6 minutes, respectively. The mean postoperative hospital stay, occlusion time and fetal radiation dose were 5.5 ± 2.6 days, 22.4 ± 7.2 minutes and 4.2 ± 2.9 mGy, respectively. There were no significant changes before and 7 days after the endovascular procedure in creatinine levels (56.8 ± 13.8 μmol/l versus 63.4 ± 16.7 μmol/l, p = 0.09) or urea nitrogen (6.3 ± 2.5 μmol/l versus 7.4 ± 3.8 μmol/l, p = 0.17). There were no access-site complications after the endovascular procedure and no complications related to the intervention during follow-up. Conclusion: Temporary aortic balloon occlusion followed by UAE can effectively control postpartum haemorrhage during placental dissection, and reduce transfusion requirements, hysterectomy rate, and operation time in patients with placenta accreta. -- Highlights: •Aortic balloon occlusion can overcome the collateral flow from other arteries. •UAE can effectively manage secondary postpartum haemorrhage. •The aortic balloon can rapidly and easily insert. •The mean

  1. Laser Fenestration of Aortic Stent-Grafts Followed by Noncompliant vs Cutting Balloon Dilation: A Scanning Electron Microscopy Study.

    Science.gov (United States)

    Lin, Jing; Parikh, Niraj; Udgiri, Naval; Wang, Shaoxia; Miller, Daniel F; Li, Chaojing; Panneton, Jean; Nutley, Mark; Zhang, Ze; Huang, Yunfan; Lu, Jun; Zhang, Jingyi; Wang, Lu; Guidoin, Robert

    2018-06-01

    To examine the effects of in situ laser fenestration and subsequent balloon dilation (noncompliant vs cutting) on the graft fabric of 4 aortic stent-graft models. In an in vitro setup, the Zenith TX2, Talent, Endurant, and Anaconda aortic stent-grafts (all made of polyester graft material) were subjected to laser fenestration with a 2.3-mm-diameter probe at low and high energy in a physiologic saline solution followed by balloon dilation of the hole. For the first series of tests, 6-mm-diameter noncompliant balloons were used and replaced for the second series by 6-mm-diameter cutting balloons. Each procedure was performed 5 times (5 fenestrations per balloon type). The fenestrations were examined visually and with light and scanning electron microscopy. Each fenestration demonstrated various degrees of fraying and/or tearing regardless of the device. The monofilament twill weave of the Talent endograft tore in the warp direction up to 7.09±0.46 mm at high energy compared with 2.41±0.26 mm for the Endurant multifilament device. The fenestrations of the 3 endografts with multifilament weave (Zenith, Anaconda, and Endurant) showed more fraying; fenestration areas in the multifilament Endurant were >10 mm 2 at low and high energy. The fenestrations were free of melted fibers, but minor blackening of the filaments was observed in all devices. Overall, the cutting balloons resulted in worse tearing and damage. Of note, the edges of the dilated laser-formed fenestrations of the Talent and the Endurant grafts demonstrated evidence of additional shredded yarns. In situ fenestration does not cause any melting of the polyester; however, the observed structural damage to the fabric construction must be carefully considered. Cutting balloons caused various levels of tearing compared to the noncompliant balloons and cannot be recommended for use in this application. Rather, noncompliant balloons should be employed, but only with endografts constructed from multifilament yarns

  2. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    Energy Technology Data Exchange (ETDEWEB)

    Fetterly, K; Mathew, V [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

  3. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    International Nuclear Information System (INIS)

    Fetterly, K; Mathew, V

    2014-01-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors

  4. The Effect of Infrarenal Aortic Balloon Occlusion on Weaning from Supraceliac Aortic Balloon Occlusion in a Porcine Model (Sus scrofa) of Hemorrhagic Shock

    Science.gov (United States)

    2017-06-15

    all animals , and continued for six hours. Half of the animals were randomly assigned to Zone-3 REBOA for an additional 45 minutes following Zone-1...concentration or resuscitation requirements.Conclusion: In an animal model of hemorrhagic shock and Zone-1 REBOA, subsequent Zone-3 aortic occlusion did not add

  5. Tackling the Issue of High Postoperative Pacemaker Implantation Rates in Sutureless Aortic Valve Replacement: Should Balloon Inflation be Removed from the Implantation Method of the Perceval Prosthesis?

    Science.gov (United States)

    Charles Blouin, Mathieu; Bouhout, Ismail; Demers, Philippe; Carrier, Michel; Perrault, Louis; Lamarche, Yoan; El-Hamamsy, Ismail; Bouchard, Denis

    2017-05-01

    Sutureless aortic valve replacement (AVR) is an emerging alternative to standard AVR in elderly and high-risk patients. This procedure is associated with a high rate of postoperative permanent pacemaker implantation (PPI). The study aim was to assess the impact on the rate of PPI of implanting the Perceval prosthesis without using balloon inflation. A total of 159 patients who underwent sutureless AVR using the Perceval prosthesis was included. Balloon inflation was used in 132 patients (Balloon group) and not used in the remaining 27 (No-Balloon group). Clinical, echocardiographic and electrocardiographic outcomes were assessed. There was no significant difference in PPI rate between the two groups (26% for Balloon group versus 22% in No-Balloon group; p = 0.700). Balloon inflation had no significant impact on the incidence of paravalvular leaks (p = 0.839), or on the need to return to cardiopulmonary bypass (CPB) intraoperatively due to paravalvular leak or unsatisfactory deployment (p >0.999). Mean and peak transaortic pressure gradients were similar between the two groups (p = 0.417 and p = 0.522, respectively). Cross-clamp and CPB times were shorter in the No-Balloon group (49.6 ± 15.9 min versus 61.1 ± 25.6 min and 64.1 ± 26.3 min versus 79.6 ± 35.4 min, respectively; p = 0.027 and p = 0.012, respectively). The two groups had similar postoperative PPI rates. Implanting the Perceval prosthesis without balloon inflation is safe and had no impact on paravalvular leaks, intraoperative complications or hemodynamic results. Reductions in aortic cross-clamp time and CPB time were observed when the balloon was not used.

  6. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. A High Performance Pulsatile Pump for Aortic Flow Experiments in 3-Dimensional Models.

    Science.gov (United States)

    Chaudhury, Rafeed A; Atlasman, Victor; Pathangey, Girish; Pracht, Nicholas; Adrian, Ronald J; Frakes, David H

    2016-06-01

    Aortic pathologies such as coarctation, dissection, and aneurysm represent a particularly emergent class of cardiovascular diseases. Computational simulations of aortic flows are growing increasingly important as tools for gaining understanding of these pathologies, as well as for planning their surgical repair. In vitro experiments are required to validate the simulations against real world data, and the experiments require a pulsatile flow pump system that can provide physiologic flow conditions characteristic of the aorta. We designed a newly capable piston-based pulsatile flow pump system that can generate high volume flow rates (850 mL/s), replicate physiologic waveforms, and pump high viscosity fluids against large impedances. The system is also compatible with a broad range of fluid types, and is operable in magnetic resonance imaging environments. Performance of the system was validated using image processing-based analysis of piston motion as well as particle image velocimetry. The new system represents a more capable pumping solution for aortic flow experiments than other available designs, and can be manufactured at a relatively low cost.

  8. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.

    Science.gov (United States)

    Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo

    2018-05-15

    Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves.

    Science.gov (United States)

    Schaefer, Andreas; Treede, Hendrik; Seiffert, Moritz; Deuschl, Florian; Schofer, Niklas; Schneeberger, Yvonne; Blankenberg, Stefan; Reichenspurner, Hermann; Schaefer, Ulrich; Conradi, Lenard

    2016-01-15

    Paravalvular leakage (PVL) is a known complication of transcatheter aortic valve implantation (TAVI) and is associated with poor outcome. Besides balloon-post-dilatation, valve-in-valve (ViV) procedures can be taken into consideration to control this complication. Herein we present initial experience with use of the latest generation balloon-expandable Edwards Sapien 3® (S3) transcatheter heart valve (THV) for treatment of failing THVs. Between 01/2014 and 12/2014 three patients (two male, age: 71-80 y, log EUROScore I: 11.89 - 32.63) with failing THVs were refered to our institution for further treatment. THV approach with secondary implantation of an S3 was chosen after mutual agreement of the local interdisciplinary heart team at an interval of 533-1119 days from the index procedure. The performed procedures consisted of: S3 in Sapien XT, JenaValve and CoreValve. Successful transfemoral implantation with significant reduction of PVL was achieved in all cases. No intraprocedural complications occurred regarding placement of the S3 with a postprocedural effective orifice area (EOA) of 1.5-2.5 cm(2) and pressure gradients of max/mean 14/6-36/16 mmHg. 30-day mortality was 0%. At the latest follow-up of 90-530 days, all patients are alive and well with satisfactory THV function. Regarding VARC-2 criteria one major bleeding and one TIA was reported. In the instance of moderate or severe aortic regurgitation after TAVI, S3 ViV deployment is an excellent option to reduce residual regurgitation to none or mild. For further assertions concerning functional outcomes long-term results have to be awaited.

  10. Long-Term Follow-Up of Percutaneous Balloon Angioplasty in Adult Aortic Coarctation

    International Nuclear Information System (INIS)

    Paddon, Alex J.; Nicholson, Anthony A.; Ettles, Duncan F.; Travis, Simon J.; Dyet, John F.

    2000-01-01

    Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). The average number of antihypertensive drugs required per patient decreased from 0.56 to 0.31 (p = 0.234). No significant residual stenoses or restenoses were seen at MRI. Small but clinically insignificant residual pressure gradients were recorded in all patients using Doppler echocardiography. Complications included one transient ischemic attack at 5 days, one external iliac dissection requiring stent insertion, and a further patient who developed a false aneurysm close to the coarctation site at 12 months which subsequently required surgical excision.Conclusion: PTA of adult coarctation is safe and effective in the long term. Although primary stenting has recently been advocated in the treatment of this condition, our results suggest that PTA remains the treatment of choice

  11. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  12. Valsartan attenuates intimal hyperplasia in balloon-injured rat aortic arteries through modulating the angiotensin-converting enzyme 2-angiotensin-(1-7)-Mas receptor axis.

    Science.gov (United States)

    Li, Yonghong; Cai, Shanglang; Wang, Qixin; Zhou, Jingwei; Hou, Bo; Yu, Haichu; Ge, Zhiming; Guan, Renyan; Liu, Xu

    2016-05-15

    The role of the Mas receptor in the activity of valsartan against intimal hyperplasia is unclear. Herein, we investigated the role of the angiotensin-converting enzyme 2 (ACE2)-angiotensin-(1-7)-Mas receptor axis on the activity of valsartan against intimal hyperplasiain balloon-injured rat aortic arteries. Wistar rats were randomized equally into the sham control group, injured group, and injured plus valsartan (20 mg/kg/d)-treated group. Valsartan significantly attenuated the vascular smooth muscle cell proliferation and intimal and medial thickening on days 14 and 28 after injury. The angiotensin-(1-7) levels as well as ACE2 and Mas receptor mRNA/protein expression were significantly decreased in the injured rats, compared to the uninjured rats; meanwhile, the angiotensin II level as well as the ACE and AT1 receptor mRNA/protein expression were increased (all P valsartan significantly increased the angiotensin-(1-7) levels as well as ACE2 and Mas receptor mRNA/protein expression but decreased the angiotensin II level, ACE and AT1 receptor mRNA/protein expression, as well as the p-ERK protein expression, compared to the injured group (all P valsartan attenuates neointimal hyperplasiain balloon-injured rat aortic arteries through activation of the ACE2-angiotensin-(1-7)-Mas axis as well as inhibition of the ACE-angiotensin II-AT1 and p-ERK pathways. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Is there a role for upper-extremity intra-aortic balloon counterpulsation as a bridge-to-recovery or a bridge-to-transplant in the treatment of end-stage heart failure?

    Science.gov (United States)

    Nwaejike, Nnamdi; Son, Andre Y; Milano, Carmelo A; Daneshmand, Mani A

    2017-10-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: Is there a role for upper-extremity intra-aortic balloon pump counterpulsation (UE-IABP) in the treatment of end-stage heart failure? Altogether 230 papers were found using the reported search, of which 6 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Of the 163 bridge-to-transplantation (BTT) patients, 141 (86.5%) were successfully transplanted and of the 9 bridge-to-recovery (BTR) patients, 6 (66.7%) were successfully weaned from the device. Length of support ranged from 3 to 152 days, and the most frequent complications were device malfunction or migration necessitating exchange or repositioning, occurring at a collective rate of 37.3%. UE-IABP is a minimally invasive and cost-effective strategy that provides haemodynamic support while preserving both the mediastinum and the functional status in BTR and BTT patients who may not tolerate more invasive modes of mechanical circulatory support. We conclude that UE-IABP can be used as a bridge-to-recovery (BTR) or transplant (BTT) in patients with end-stage heart failure. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Five-Year Outcomes of the First Pivotal Clinical Trial of Balloon-Expandable Transcatheter Aortic Valve Replacement in Japan (PREVAIL JAPAN).

    Science.gov (United States)

    Sawa, Yoshiki; Takayama, Morimasa; Goto, Tsuyoshi; Takanashi, Shuichiro; Komiya, Tatsuhiko; Tobaru, Tetsuya; Maeda, Koichi; Kuratani, Toru; Sakata, Yasushi

    2017-07-25

    Transcatheter aortic valve replacement (TAVR) has been an alternative less invasive therapy for high-surgical risk/inoperable patients with aortic valve stenosis (AS) in Japan. We report 5-year outcomes of the first pivotal clinical trial of TAVR in Japan (PREVAIL JAPAN).Methods and Results:A total of 64 patients with AS who were considered unsuitable candidates for surgery were enrolled at 3 centers in Japan (mean age: 84.3±6.1 years, female: 65.6%, STS score: 9.0±4.5%). Transfemoral approach (TF) and transapical approach (TA) was performed in 37 patients and 27 patients, respectively. At 5 years, freedom from all-cause death was 52.7% (TF: 51.3%, TA: 56.3%). Risk of all stroke at 5-year was 15.8% (TF: 8.9%, TA: 25.5%) and risk of major adverse cardiac and cerebrovascular events at 5 years was 58.0% (TF: 51.3%, TA: 69.2%). Mild or greater aortic regurgitation (AR) at 1 week was not associated with increased all-cause death at 5 years (69.1%) compared with none or trace AR (48.3%) (P=0.184). Patients with high STS score (>8) had higher mortality rate than those with low STS scores (≤8). The 5-year data from PREVAIL JAPAN show the clinical benefit of TAVR and suggest that balloon-expandable TAVR is an effective treatment option for Japanese patients with severe AS who are not suitable for surgery. (Funded by Edwards Lifesciences Limited; ClinicalTrials.gov number, NCT01113983.).

  15. Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition.

    Science.gov (United States)

    Eltchaninoff, Hélène; Durand, Eric; Avinée, Guillaume; Tron, Christophe; Litzler, Pierre-Yves; Bauer, Fabrice; Dacher, Jean-Nicolas; Werhlin, Camille; Bouhzam, Najime; Bettinger, Nicolas; Candolfi, Pascal; Cribier, Alain

    2018-03-30

    Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.

  16. Transcatheter aortic valve implantation and off-pump coronary artery bypass surgery: an effective hybrid procedure in selected patients.

    Science.gov (United States)

    Mayr, Benedikt; Firschke, Christian; Erlebach, Magdalena; Bleiziffer, Sabine; Krane, Markus; Joner, Michael; Herold, Ulf; Nöbauer, Christian; Lange, Rüdiger; Deutsch, Marcus-André

    2018-02-26

    Simultaneous surgical off-pump coronary revascularization and transcatheter aortic valve implantation (TAVI) as a hybrid procedure may be a therapeutic option for patients with a TAVI indication who are not suitable for percutaneous coronary intervention and for patients who have an indication for combined surgical aortic valve implantation and coronary artery bypass grafting but present with a porcelain aorta. Early outcomes of these patients are analysed in this study. From February 2011 to April 2017, hybrid TAVI/off-pump coronary artery bypass (OPCAB) was performed in 12 (60%) patients, hybrid TAVI/minimally invasive direct coronary artery bypass in 6 (30%) patients and staged TAVI/OPCAB in 2 (10%) patients. Endpoints of this study were 30-day mortality, device success and postoperative adverse events as defined by the updated Valve Academic Research Consortium (VARC-2). The median age at the time of surgery was 77 years [interquartile range (IQR), 70-81] with a median logistic EuroSCORE and Society of Thoracic Surgeons' Predicted Risk score of 16.1% (IQR, 9.3-28.1) and 3.9% (IQR, 2.2-5.6), respectively. The median Synergy between PCI with Taxus and Cardiac Surgery score was 16.5 (IQR, 9.8-22.8). TAVI implantation routes were transaortic in 9 (45%) patients, transapical and transfemoral in 5 (25%) patients each and transsubclavian in 1 (5%) patient. Complete myocardial revascularization was achieved in 75% of patients. Device success rate was 100%. Paravalvular aortic regurgitation did not exceed mild in any patient. Stroke/transient ischaemic attack, vascular complications and myocardial infarction were not observed. Re-exploration for bleeding was required in 1 (5%) patient. Thirty-day mortality was 0%. Hybrid OPCAB/MIDCAB and TAVI prove to be a safe and effective alternative treatment option in selected higher risk patients.

  17. Anesthetic management of cesarean section in cases of placenta accreta, with versus without abdominal aortic balloon occlusion: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Chu, Qinjun; Shen, Dan; He, Long; Wang, Hongwei; Zhao, Xianlan; Chen, Zhimin; Wang, Yanli; Zhang, Wei

    2017-05-26

    Placenta accreta (PA), a severe complication during delivery, is closely linked with massive hemorrhage which could endanger the lives of both mother and baby. Moreover, the incidence of PA has increased dramatically with the increasing rate of cesarean deliveries in the past few decades. Therefore, studies evaluating the effects of different perioperative managements based on different modalities in the treatment of PA are necessary. Among the numerous treatment measures, prophylactic abdominal aortic balloon occlusion (AABO) in combination with cesarean section for PA seems to be more advantageous than others. However, up to now, all studies on AABO were almost retrospective. Current evidence is insufficient to recommend for or against routinely using the AABO technology for control intraoperative hemorrhage in patients with PA. Thus, we hope to carry out a prospective, randomized controlled trial (RCT) study to confirm the effectiveness of the AABO technology in patients with PA. This trial is an investigator-initiated, prospective RCT that will test the superiority of AABO in combination with cesarean section compared to the traditional hysterectomy following cesarean section for parturients with PA. A total of 170 parturients with PA undergoing cesarean section will be randomized to receive either AABO in combination with cesarean section or the traditional hysterectomy following cesarean section. The primary outcome is estimated blood loss. The most important secondary outcome is the occurrence of cesarean hysterectomy during delivery; others include blood transfusion volume, operating time, neonate's Apgar scores (collected at 1, 5 and 10 min), length of stay in intensive care unit, total hospital stay, and balloon occlusion-relative data. This prospective trial will test the superiority of AABO in combination with cesarean section compared to the traditional hysterectomy following cesarean section for parturients with PA. It may provide strong evidence

  18. Six-Month Outcomes After High-Risk Coronary Artery Bypass Graft Surgery and Preoperative Intra-aortic Balloon Counterpulsation Use: An Inception Cohort Study.

    Science.gov (United States)

    Litton, Edward; Bass, Frances; Delaney, Anthony; Hillis, Graham; Marasco, Silvana; McGuinness, Shay; Myles, Paul S; Reid, Christopher M; Smith, Julian A

    2018-01-05

    To inform the design of a pivotal randomized controlled trial of prophylactic intra-aortic balloon counterpulsation (IABC) in patients undergoing coronary artery bypass graft (CABG) at high risk of postoperative low cardiac output syndrome (LCOS). Inception cohort study. A total of 13 established cardiac centers in Australia, Canada, New Zealand, and the United Kingdom. Adult patients were eligible for inclusion if they were listed for CABG surgery and had 2 or more LCOS risk factors (low ejection fraction, severe left main coronary artery disease, redo sternotomy, unstable angina). Outcomes of interest were a composite outcome of in-hospital mortality, postoperative acute myocardial infarction (AMI), acute kidney injury (AKI), or stroke as well as 6-month vital status and quality of life using the EuroQol 5-dimensional questionnaire (EQ5D). The study included 136 participants over a 29-month period. Overall, in-hospital and 6-month mortality occurred in 7 (5%) and 11 (8%) participants, respectively. The composite outcome occurred in 60 (44%). The mean increase in EQ5D summary index at 6 months was 0.10 (standard deviation 0.24, p = 0.01). Perioperative AMI, AKI, or stroke significantly decreased the odds of a clinically meaningful improvement in quality of life (odds ratio 0.32; 95% confidence interval 0.13-0.79; p = 0.014). Preoperative IABC was used in 39 participants and did not predict postoperative outcomes. The study identified a group of patients at risk of LCOS in whom CABG surgery was associated with a substantial burden of perioperative morbidity. Preoperative IABC use was variable, supporting the need for further research. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Aspirin Versus Aspirin Plus Clopidogrel as Antithrombotic Treatment Following Transcatheter Aortic Valve Replacement With a Balloon-Expandable Valve: The ARTE (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation) Randomized Clinical Trial.

    Science.gov (United States)

    Rodés-Cabau, Josep; Masson, Jean-Bernard; Welsh, Robert C; Garcia Del Blanco, Bruno; Pelletier, Marc; Webb, John G; Al-Qoofi, Faisal; Généreux, Philippe; Maluenda, Gabriel; Thoenes, Martin; Paradis, Jean-Michel; Chamandi, Chekrallah; Serra, Vicenç; Dumont, Eric; Côté, Mélanie

    2017-07-10

    The aim of this study was to compare aspirin plus clopidogrel with aspirin alone as antithrombotic treatment following transcatheter aortic valve replacement (TAVR) for the prevention of ischemic events, bleeding events, and death. Few data exist on the optimal antithrombotic therapy following TAVR. This was a randomized controlled trial comparing aspirin (80 to 100 mg/day) plus clopidogrel (75 mg/day) (dual antiplatelet therapy [DAPT]) versus aspirin alone (single-antiplatelet therapy [SAPT]) in patients undergoing TAVR with a balloon-expandable valve. The primary endpoint was the occurrence of death, myocardial infarction (MI), stroke or transient ischemic attack, or major or life-threatening bleeding (according to Valve Academic Research Consortium 2 definitions) within the 3 months following the procedure. The trial was prematurely stopped after the inclusion of 74% of the planned study population. A total of 222 patients were included, 111 allocated to DAPT and 111 to SAPT. The composite of death, MI, stroke or transient ischemic attack, or major or life-threatening bleeding tended to occur more frequently in the DAPT group (15.3% vs. 7.2%, p = 0.065). There were no differences between groups in the occurrence of death (DAPT, 6.3%; SAPT, 3.6%; p = 0.37), MI (DAPT, 3.6%; SAT, 0.9%; p = 0.18), or stroke or transient ischemic attack (DAPT, 2.7%; SAPT, 0.9%; p = 0.31) at 3 months. DAPT was associated with a higher rate of major or life-threatening bleeding events (10.8% vs. 3.6% in the SAPT group, p = 0.038). There were no differences between groups in valve hemodynamic status post-TAVR. This small trial showed that SAPT (vs. DAPT) tended to reduce the occurrence of major adverse events following TAVR. SAPT reduced the risk for major or life-threatening events while not increasing the risk for MI or stroke. Larger studies are needed to confirm these results. (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation: The ARTE

  20. Retained intraaortic balloon. Case report and review of the literature.

    Science.gov (United States)

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.

  1. Systematic Design of a Magnetically Levitated Brushless DC Motor for a Reversible Rotary Intra-Aortic Blood Pump.

    Science.gov (United States)

    Wang, Yaxin; Logan, Thomas G; Smith, P Alex; Hsu, Po-Lin; Cohn, William E; Xu, Liping; McMahon, Richard A

    2017-10-01

    The IntraVAD is a miniature intra-aortic ventricular assist device (VAD) designed to work in series with the compromised left ventricle. A reverse-rotation control (RRc) mode has been developed to increase myocardial perfusion and reduce ventricular volume. The RRc mode includes forward rotation in systole and reverse rotation in diastole, which requires the IntraVAD to periodically reverse its rotational direction in synchrony with the cardiac cycle. This periodic reversal leads to changes in pressure force over the impeller, which makes the entire system less stable. To eliminate the mechanical wear of a contact bearing and provide active control over the axial position of the rotor, a miniature magnetically levitated bearing (i.e., the PM-Coil module) composed of two concentric permanent magnetic (PM) rings and a pair of coils-one on each side-was proposed to provide passive radial and active axial rotor stabilization. In the early design stage, the numerical finite element method (FEM) was used to optimize the geometry of the brushless DC (BLDC) motor and the maglev module, but constructing a new model each time certain design parameters were adjusted required substantial computation time. Because the design criteria for the module had to be modified to account for the magnetic force produced by the motor and for the hemodynamic changes associated with pump operation, a simplified analytic expression was derived for the expected magnetic forces. Suitable bearings could then be designed capable of overcoming these forces without repeating the complicated FEM simulation for the motor. Using this method at the initial design stage can inform the design of the miniature maglev BLDC motor for the proposed pulsatile axial-flow VAD. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. Resuscitative Endovascular Balloon Occlusion of the Aorta and Resuscitative Thoracotomy in Select Patients with Hemorrhagic Shock: Early Results from the American Association for the Surgery of Trauma's Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery Registry.

    Science.gov (United States)

    Brenner, Megan; Inaba, Kenji; Aiolfi, Alberto; DuBose, Joseph; Fabian, Timothy; Bee, Tiffany; Holcomb, John B; Moore, Laura; Skarupa, David; Scalea, Thomas M

    2018-05-01

    Aortic occlusion is a potentially valuable tool for early resuscitation in patients nearing extremis or in arrest from severe hemorrhage. The American Association for the Surgery of Trauma's Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery registry identified trauma patients without penetrating thoracic injury undergoing aortic occlusion at the level of the descending thoracic aorta (resuscitative thoracotomy [RT] or zone 1 resuscitative endovascular balloon occlusion of the aorta [REBOA]) in the emergency department (ED). Survival outcomes relative to the timing of CPR need and admission hemodynamic status were examined. Two hundred and eighty-five patients were included: 81.8% were males, with injury due to penetrating mechanisms in 41.4%; median age was 35.0 years (interquartile range 29 years) and median Injury Severity Score was 34.0 (interquartile range 18). Resuscitative thoracotomy was used in 71%, and zone 1 REBOA in 29%. Overall survival beyond the ED was 50% (RT 44%, REBOA 63%; p = 0.004) and survival to discharge was 5% (RT 2.5%, REBOA 9.6%; p = 0.023). Discharge Glasgow Coma Scale score was 15 in 85% of survivors. Prehospital CPR was required in 60% of patients with a survival beyond the ED of 37% and survival to discharge of 3% (all p > 0.05). Patients who did not require any CPR before had a survival beyond the ED of 70% (RT 48%, REBOA 93%; p American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  4. A comparison of Selective Aortic Arch Perfusion and Resuscitative Endovascular Balloon Occlusion of the Aorta for the management of hemorrhage-induced traumatic cardiac arrest: A translational model in large swine.

    Directory of Open Access Journals (Sweden)

    Ed B G Barnard

    2017-07-01

    Full Text Available Survival rates remain low after hemorrhage-induced traumatic cardiac arrest (TCA. Noncompressible torso hemorrhage (NCTH is a major cause of potentially survivable trauma death. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA at the thoracic aorta (Zone 1 can limit subdiaphragmatic blood loss and allow for IV fluid resuscitation when intrinsic cardiac activity is still present. Selective Aortic Arch Perfusion (SAAP combines thoracic aortic balloon hemorrhage control with intra-aortic oxygenated perfusion to achieve return of spontaneous circulation (ROSC when cardiac arrest has occurred.Male Yorkshire Landrace cross swine (80.0 ± 6.0 kg underwent anesthesia, instrumentation for monitoring, and splenectomy. TCA was induced by laparoscopic liver lobe resection combined with arterial catheter blood withdrawal to achieve a sustained systolic blood pressure <10 mmHg, cardiac arrest. After 3 min of arrest, swine were allocated to one of three interventions: (1 REBOA plus 4 units of IV fresh whole blood (FWB, (2 SAAP with oxygenated lactated Ringer's (LR, 1,600 mL/2 min, or (3 SAAP with oxygenated FWB 1,600 mL/2 min. Primary endpoint was survival to the end of 60 min of resuscitation, a simulated prehospital phase. Thirty animals were allocated to 3 groups (10 per group-5 protocol exclusions resulted in a total of 35 animals being used. Baseline measurements and time to cardiac arrest were not different amongst groups. ROSC was achieved in 0/10 (0%, 95% CI 0.00-30.9 REBOA, 6/10 (60%, 95% CI 26.2-87.8 SAAP-LR and 10/10 (100%, 95% CI 69.2-100.0 SAAP-FWB animals, p < 0.001. Survival to end of simulated 60-minute prehospital resuscitation was 0/10 (0%, 95% CI 0.00-30.9 for REBOA, 1/10 (10%, 95% CI 0.25-44.5 for SAAP-LR and 9/10 (90%, 95% CI 55.5-99.7 for SAAP-FWB, p < 0.001. Total FWB infusion volume was similar for REBOA (2,452 ± 0 mL and SAAP-FWB (2,250 ± 594 mL. This study was undertaken in laboratory conditions, and as such may have

  5. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  6. Balloon sinuplasty

    OpenAIRE

    Ahmad, Zahoor

    2010-01-01

    Balloon sinuplasty is a technique in endoscopic sinus surgery that involves minimally invasive procedures to dilate the obstructed or stenosed anatomical sinus pathways. Procedure is derived from the well-recognized techinique of angioplasty. This article highlights the procedural methods with review of literature and my personal experience in balloon sinupalsty.

  7. [Anesthetic Management of a Patient Complicated with Marfan Syndrome and Suffering from Stanford Type A Aortic Dissection during Pregnancy].

    Science.gov (United States)

    Uozaki, Nako; Mizuno, Kaori; Shiraishi, Yoshito; Doi, Matsuyuki; Sato, Shigehito

    2015-04-01

    We report a case of a 36-year-old woman at 34 weeks of gestation complicated with Marfan syndrome who underwent Bentall type aortic replacement surgery due to Stanford type A aortic dissection after undergoing caesarean section. Since this patient exhibited severe hypotension before coming to the operating room, it was very difficult to determine whether the cardiac surgery or caesarean section should be performed first. In this case, the caesarean section was performed first, followed by Bentall's surgery. Although intra-aortic balloon pumping and percutaneous cardiopulmonary support were required after weaning from the cardiopulmonary bypass, she was discharged on post-operative day (POD) 40 and the baby was discharged on POD 60, without signs of cerebral palsy. Unfortunately, this patient died on POD 57, due to heart failure. We discuss how to determine the priority of surgeries for patients who require emergency surgery for cardiovascular disease during pregnancy.

  8. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    Science.gov (United States)

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon

  9. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  10. Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Shahrbano Shahbazi

    2013-12-01

    Full Text Available Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG. Methods: In 146 patients scheduled for on-pump CABG, the liver function test was done preoperatively and on the first postoperative day. Some preoperative and intraoperative risk factors were checked and then the postoperative liver function tests were compared with the preoperative ones. Probable relationships between these changes and the preoperative and intraoperative risk factors were studied. Results: A medical history of diabetes had a significant relationship with the changes in direct bilirubin. Preoperative central venous pressure had a significant relationship with the changes in aspartate aminotransferase and alanine aminotransferase. Use of intra-aortic balloon pump and duration of aortic cross-clamp were significantly related to the changes in the liver function tests except for alanine aminotransferase and alkaline phosphatase. Conclusion: It seems that the techniques for the reduction of cardiopulmonary bypass and aortic cross-clamp duration may be useful to protect liver function. We recommend that a larger population of patients be studied to confirm these findings.

  11. Aortic insufficiency

    Science.gov (United States)

    ... page, please enable JavaScript. Aortic insufficiency is a heart valve disease in which the aortic valve does not close ... aortic insufficiency Images Aortic insufficiency References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  12. Vascular Rupture Caused by a Molding Balloon during Endovascular Aneurysm Repair: Case Report

    International Nuclear Information System (INIS)

    Lee, Hee Young; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo; Kim, Young Wook; Kim, Dong Ik

    2011-01-01

    Endovascular aneurysm repair (EVAR) has been accepted as an alternative to traditional open surgery in selected patients. Despite the minimally invasiveness of this treatment, several complications may occur during or after EVAR. Complications include endoleak, aortic dissection, distal embolism, or iatrogenic injury to the access artery. However, there are few reports on the vascular rupture caused by a molding balloon during EVAR. We report two cases of infrarenal abdominal aortic aneurysms complicated by procedure-related aortic or iliac artery rupture by the molding balloon during EVAR. In our cases, we observed suddenly abrupt increase of the diameter of the endograft during balloon inflation, because we inflated the balloon rapidly. In conclusion, careful attention must be paid during inflation of the molding balloon to prevent vascular rupture.

  13. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    Science.gov (United States)

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Energy from solar balloons

    Energy Technology Data Exchange (ETDEWEB)

    Grena, Roberto [C. R. Casaccia, via Anguillarese 301, 00123 Roma (Italy)

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  15. The Effect Of Supraphysiologic Blood Pressure on Traumatic Brain Injury and Proximal Tissue Beds During Resuscitative Balloon Occlusion of the Aorta and Variable Aortic Control in a Porcine Model (Sus scrofa) of Polytrauma.

    Science.gov (United States)

    2017-04-27

    Control In A Porcine Model (Sus Scrofa) Of Polytrauma . PRINCIPAL INVESTIGATOR (PI) / TRAINING COORDINATOR (TC): Lt Col Timothy Williams DEPARTMENT...Mandatory) The Effect of REBOA, Partial Aortic Occlusion and Aggressive Blood Transfusion on Traumatic Brain Injury in a Swine Polytrauma Model

  16. Neonatal aortic stenosis.

    Science.gov (United States)

    Drury, Nigel E; Veldtman, Gruschen R; Benson, Lee N

    2005-09-01

    Neonatal aortic stenosis is a complex and heterogeneous condition, defined as left ventricular outflow tract obstruction at valvular level, presenting and often requiring treatment in the first month of life. Initial presentation may be catastrophic, necessitating hemodynamic, respiratory and metabolic resuscitation. Subsequent management is focused on maintaining systemic blood flow, either via a univentricular Norwood palliation or a biventricular route, in which the effective aortic valve area is increased by balloon dilation or surgical valvotomy. In infants with aortic annular hypoplasia but adequately sized left ventricle, the Ross-Konno procedure is also an attractive option. Outcomes after biventricular management have improved in recent years as a consequence of better patient selection, perioperative management and advances in catheter technology. Exciting new developments are likely to significantly modify the natural history of this disorder, including fetal intervention for the salvage of the hypoplastic left ventricle; 3D echocardiography providing better definition of valve morphology and aiding patient selection for a surgical or catheter-based intervention; and new transcutaneous approaches, such as duel beam echo, to perforate the valve.

  17. Genetics Home Reference: supravalvular aortic stenosis

    Science.gov (United States)

    ... and narrower than usual. A thickened aorta is less flexible and resilient to the stress of constant blood flow and pumping of the heart. Over time, the wall of the aorta can become damaged. Aortic narrowing causes the heart to work harder to pump blood through the aorta, resulting ...

  18. Endoluminal treatment of aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, Ajay; Lotz, Joachim; Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Strasse 1, 30625, Hannover (Germany); Oelert, Frank; Haverich, Axel; Karck, Matthias [Department of Thoracic and Cardiovascular Surgery, Hannover Medical School, Carl Neuberg Strasse 1, 30625, Hannover (Germany)

    2003-11-01

    Aortic dissection is most often a catastrophic medical emergency which, if untreated, can be potentially fatal. The intention of therapy in patients with aortic dissection is to prevent aortic rupture or aneurysm formation as well as to relieve branch vessel ischaemia. Patients with aortic dissection are often poor candidates for anaesthesia and surgery and the surgical procedure itself is challenging requiring thoracotomy, aortic cross clamping, blood transfusion as well as prolonged hospital stay in some cases. Operative mortality is especially high in patients with critical mesenteric or renal ischaemia. The past decade has experienced the emergence of a number of interventional radiological or minimally invasive techniques which have significantly improved the management of patients with aortic dissection. These include stent grafting for entry site closure to prevent aneurysmatic widening of the false lumen as well as percutaneous techniques such as balloon fenestration of the intimal flap and aortic true lumen stenting to alleviate branch vessel ischaemia. False lumen thrombosis following entry closure with stent grafts has been observed in 86-100% of patients, whereas percutaneous interventions are able to effectively relieve organ ischaemia in approximately 90% of the cases. In the years to come, it is to be expected that these endoluminal techniques will become the method of choice for treating most type-B dissections and will assist in significantly reducing the number of open surgical procedures required for type-A dissections. The intention of this article is to provide an overview of the current status of these endoluminal techniques based on our own experience as well as on a review of the relevant literature. (orig.)

  19. Endoluminal treatment of aortic dissection

    International Nuclear Information System (INIS)

    Chavan, Ajay; Lotz, Joachim; Galanski, Michael; Oelert, Frank; Haverich, Axel; Karck, Matthias

    2003-01-01

    Aortic dissection is most often a catastrophic medical emergency which, if untreated, can be potentially fatal. The intention of therapy in patients with aortic dissection is to prevent aortic rupture or aneurysm formation as well as to relieve branch vessel ischaemia. Patients with aortic dissection are often poor candidates for anaesthesia and surgery and the surgical procedure itself is challenging requiring thoracotomy, aortic cross clamping, blood transfusion as well as prolonged hospital stay in some cases. Operative mortality is especially high in patients with critical mesenteric or renal ischaemia. The past decade has experienced the emergence of a number of interventional radiological or minimally invasive techniques which have significantly improved the management of patients with aortic dissection. These include stent grafting for entry site closure to prevent aneurysmatic widening of the false lumen as well as percutaneous techniques such as balloon fenestration of the intimal flap and aortic true lumen stenting to alleviate branch vessel ischaemia. False lumen thrombosis following entry closure with stent grafts has been observed in 86-100% of patients, whereas percutaneous interventions are able to effectively relieve organ ischaemia in approximately 90% of the cases. In the years to come, it is to be expected that these endoluminal techniques will become the method of choice for treating most type-B dissections and will assist in significantly reducing the number of open surgical procedures required for type-A dissections. The intention of this article is to provide an overview of the current status of these endoluminal techniques based on our own experience as well as on a review of the relevant literature. (orig.)

  20. An unusual case of aortic rupture after deployment of a bare stent in the treatment of aortic dissection in a patient with giant-cell arteritis.

    Science.gov (United States)

    Rynio, Pawel; Kazimierczak, Arkadiusz; Gutowski, Piotr; Cnotliwy, Miloslaw

    2017-06-01

    Giant-cell arteritis is associated with a higher risk of aortic aneurysm and aortic dissection formation. We present a women with aortic dissection type B treated with a stent graft and bare-metal stent implantation. After the stent deployment we noticed aortic rupture, which was successfully treated with implantation of an additional stent graft. This report highlights the difficulty of endovascular therapy in patients with giant-cell arteritis. We have to bear in mind that chronic inflammation of the aorta leads to a more fragile aortic wall than normal. We recommend the use of a stent graft over a bare-metal stent and gentle use of a balloon catheter.

  1. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  2. Aorto-aortic intrathoracic bypass in surgical treatment of aortic

    International Nuclear Information System (INIS)

    Gutierrez Perez, F.; Duran Reyes, A.; Bigalli, D.; Filgueira Berobide, J.

    1998-01-01

    The prevalence of coarctation of the aorta is 6.5 percent of all congenital heart defects, according to national and international data. There is a restenosis rate of patients after surgery. Factors that influence this evolution depends on the age at which patients underwent surgery for the first time the anatomy of the aortic arch and type of surgical technique. Several procedures can be used to correct the coarctation, which include surgery and balloon catheter dilation. We present here a case of a patient of 22 years old, with a recurrent coarctation of the aorta studied by echocardiography and magnetic resonance imaging. The patient underwent surgery a third time. We used an anterior approach (median sternotomy) and performed an aortic bypass graft, intrathoracic, under cardiopulmonary bypass. Evolved favorably and was discharged on the sixth day of post operative day (Author) [es

  3. Aortic stenosis

    Science.gov (United States)

    ... Images Aortic stenosis Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ... ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/ ...

  4. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  5. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  6. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  7. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  8. Two Tethered Balloon Systems

    Science.gov (United States)

    Youngbluth, Otto; Owens, Thomas L.; Storey, Richard W.

    1990-01-01

    Systems take meteorological measurements for variety of research projects. Report describes work done by NASA Langley Research Center in atmospheric research using tethered balloon systems composed of commercially available equipment. Two separate tethered balloon systems described in report have payloads and configurations tailored to requirements of specific projects. Each system capable of measuring atmospheric parameter or species in situ and then telemetering this data in real time to ground station. Meteorological data and concentration of ozone typically measured. Indicates instrumented tethered balloon systems have distinct advantages over other systems for gathering data on troposphere.

  9. [Valvuloplasty with balloon catheter in biologic prosthesis. Reality or illusion].

    Science.gov (United States)

    Ledesma Velasco, M; Verdín Vázquez, R; Acosta Valdez, J L; Munayer Calderón, J; Salgado Escobar, J L; Arias Monroy, L; Flores Mendoza, J

    1989-01-01

    We performed catheter balloon valvuloplasty (CBV) on 8 stenotic operatively-excised bioprosthetic valves (2 Hancock and 6 Ionescu Shiley). Pathology of valves before CBV included degenerative changes: commissural fusion by mounds of calcific deposits (2 valves), fibrotic and focally calcified leaflets (7 valves) and stiff and thick valves (1 valve). Inflation of the balloon resulted in commissural splitting (2 valves), leaflet cracks and fractures (3 valves). Removal of the deflated balloon catheter was associated with debris dislodgement (3 valves). In one case the valve was unable to close with potential for acute regurgitation. Thus, CBV of bioprosthetic valves can split fused commissures by similar mechanisms as in native valves. CBV may fracture calcific deposits causing acute emboli. It can also disrupt the leaflets causing acute insufficiency. The findings suggest a limited role of CBV in the treatment of stenotic bioprosthetic valves in mitral and aortic position.

  10. Ballooning Interest in Science.

    Science.gov (United States)

    Kim, Hy

    1992-01-01

    Presents an activity in which students construct model hot air balloons to introduce the concepts of convection current, the principles of Charles' gas law, and three-dimensional geometric shapes. Provides construction and launching instructions. (MDH)

  11. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  12. Apical ballooning syndrome complicated by acute severe mitral regurgitation with left ventricular outflow obstruction – Case report

    Directory of Open Access Journals (Sweden)

    Celermajer David S

    2007-02-01

    Full Text Available Abstract Background Apical ballooning syndrome (or Takotsubo cardiomyopathy is a syndrome of transient left ventricular apical ballooning. Although first described in Japanese patients, it is now well reported in the Caucasian population. The syndrome mimicks an acute myocardial infarction but is characterised by the absence of obstructive coronary disease. We describe a serious and poorly understood complication of Takotsubo cardiomyopathy. Case Presentation We present the case of a 65 year-old lady referred to us from a rural hospital where she was treated with thrombolytic therapy for a presumed acute anterior myocardial infarction. Four hours after thrombolysis she developed acute pulmonary oedema and a new systolic murmur. It was presumed she had acute mitral regurgitation secondary to a ruptured papillary muscle, ischaemic dysfunction or an acute ventricular septal defect. Echocardiogram revealed severe mitral regurgitation, left ventricular apical ballooning, and systolic anterior motion of the mitral valve with significant left ventricular outflow tract gradient (60–70 mmHg. Coronary angiography revealed no obstructive coronary lesions. She had an intra-aortic balloon pump inserted with no improvement in her parlous haemodynamic state. We elected to replace her mitral valve to correct the outflow tract gradient and mitral regurgitation. Intra-operatively the mitral valve was mildly myxomatous but there were no structural abnormalities. She had a mechanical mitral valve replacement with a 29 mm St Jude valve. Post-operatively, her left ventricular outflow obstruction resolved and ventricular function returned to normal over the subsequent 10 days. She recovered well. Conclusion This case represents a serious and poorly understood association of Takotsubo cardiomyopathy with acute pulmonary oedema, severe mitral regurgitaton and systolic anterior motion of the mitral valve with significant left ventricular outflow tract obstruction. The

  13. Aortic embolization of an Edwards SAPIEN prosthesis due to sigmoid left ventricular hypertrophy: Case report.

    Science.gov (United States)

    Yuksel, Isa Öner; Koklu, Erkan; Arslan, Sakir; Cagirci, Goksel; Kucukseymen, Selcuk

    2016-06-01

    Transcatheter aortic valve implantation (TAVI) is considered an alternative therapy in high-risk patients with severe aortic stenosis. Although a minimally invasive procedure, it is not free from complications, one of which is valve embolization at the time of TAVI. We present a case of embolization of a balloon-expandable aortic valve due to sigmoid left ventricular hypertrophy and managed with a second valve without surgery. The embolized valve was repositioned in the aortic arch between the left common carotid artery and the brachiocephalic trunk. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  14. Aortic rupture during aortoplasty in Takayasu arteritis – A rare complication: Case report and review of literature

    Directory of Open Access Journals (Sweden)

    Vimal Mehta

    2014-05-01

    Full Text Available Balloon angioplasty of the stenosed aorta is usually a relatively simple, yet potentially a catastrophic procedure. Aortic rupture during aortoplasty, though uncommon, carries a high mortality. We report case of a 39-year-old female with aortoarteritis with multiple arterial stenoses whose infra-renal abdominal aorta ruptured during balloon dilatation of the stent deployed in that segment. The site of aortic rupture was temporarily occluded by low-pressure inflation of the same balloon and then was sealed using a stent-graft introduced by contra-lateral femoral arterial access.

  15. Launching Garbage-Bag Balloons.

    Science.gov (United States)

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  16. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    Burnett, T.; Iwai, J.; Lord, J.J.; Strausz, S.; Wilkes, R.J.; Dake, S.; Oda, H.; Miyamura, O.; Fuki, M.; Jones, W.V.; Gregory, J.; Hayashi, T.; Takahashi, U.; Tominaga, Y.; Wefel, J.P.; Fountain, W.; Derrickson, J.; Parnell, T.A.; Roberts, E.; Tabuki, T.; Watts, J.W.

    1989-01-01

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  17. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  18. Adjustable continence balloons

    DEFF Research Database (Denmark)

    Kjær, Line; Fode, Mikkel; Nørgaard, Nis

    2012-01-01

    Abstract Objective. This study aimed to evaluate the results of the Danish experience with the ProACT urinary continence device inserted in men with stress urinary incontinence. Material and methods. The ProACT was inserted in 114 patients. Data were registered prospectively. The main endpoints...... in urinary leakage > 50% was seen in 72 patients (80%). Complications were seen in 23 patients. All of these were treated successfully by removal of the device in the outpatient setting followed by replacement of the device. Another eight patients had a third balloon inserted to improve continence further....... Fourteen patients (12%) ended up with an artificial sphincter or a urethral sling. Sixty patients (63%) experienced no discomfort and 58 (61%) reported being dry or markedly improved. Overall, 50 patients (53%) reported being very or predominantly satisfied. Conclusions. Adjustable continence balloons seem...

  19. Hot air balloon engine

    Energy Technology Data Exchange (ETDEWEB)

    Edmonds, Ian [Solartran Pty Ltd, 12 Lentara Street, Kenmore, Brisbane 4069 (Australia)

    2009-04-15

    This paper describes a solar powered reciprocating engine based on the use of a tethered hot air balloon fuelled by hot air from a glazed collector. The basic theory of the balloon engine is derived and used to predict the performance of engines in the 10 kW to 1 MW range. The engine can operate over several thousand metres altitude with thermal efficiencies higher than 5%. The engine thermal efficiency compares favorably with the efficiency of other engines, such as solar updraft towers, that also utilize the atmospheric temperature gradient but are limited by technical constraints to operate over a much lower altitude range. The increased efficiency allows the use of smaller area glazed collectors. Preliminary cost estimates suggest a lower $/W installation cost than equivalent power output tower engines. (author)

  20. The Inflammatory Sequelae of Aortic Balloon Occlusion in Hemorrhagic Shock

    Science.gov (United States)

    2014-04-13

    respectively. There was a trend toward greater vasopressor use (P ¼ 0.183) and increased incidence of acute respiratory distress syndrome (P ¼ 0.052) across the...Jansen JO. Intra operative correction of acidosis , coagulopathy and hypothermia in combat casualties with severe haemorrhagic shock. Anaesthesia...noncompressible torso hemorrhage. J Trauma 2011;71:S131. [19] Ranieri VM, Rubenfeld GD, Thompson BT, et al. Acute respiratory distress syndrome: the

  1. Aortic Annular Enlargement during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Selman Dumani

    2016-09-01

    Full Text Available In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.

  2. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  3. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  4. Fracture of the delivery balloon shaft during balloon-expandable prosthesis alignment during implantation of an Edwards SAPIEN 3.

    Science.gov (United States)

    Arai, Takahide; Hovasse, Thomas; Chevalier, Bernard

    2018-04-01

    The expandable sheath was designed with a lower profile in order to reduce the incidence of vascular complications of transcatheter aortic valve implantation using transfemoral approach. However, once the prosthesis has crossed the sheath, it could be difficult to retrieve it from the body. This is the first case of successful bail-out in an instance of delivery balloon shaft malfunction subsequent to the crossing of an expandable sheath during implantation of an Edwards SAPIEN 3 prosthesis. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. O uso do balão intra-aórtico no pré-operatório de cirurgia de revascularização miocárdica, associada à disfunção ventricular grave The use of preoperative intra-aortic balloon in myocardial revascularization surgery associated to severe ventricular dysfunction

    Directory of Open Access Journals (Sweden)

    Marcelo Kern

    2006-02-01

    Full Text Available OBJETIVO: Avaliar a efetividade do Balão Intra-Aórtico (BIAo profilático em cirurgia de revascularização miocárdica (CRM eletiva, para prevenir o infarto trans ou pós-operatório e para reduzir a mortalidade intra-hospitalar nos pacientes com baixa fração de ejeção ventricular esquerda. MÉTODOS: Em modelo de estudo de coorte, foram analisados 239 pacientes com fração de ejeção do ventrículo esquerdo inferior ou igual a 40%, submetidos à CRM eletiva com circulação extracorpórea (CEC, no período compreendido entre março de 1995 a fevereiro de 2001. RESULTADOS: Destes, 58 pacientes receberam BIAo pré-operatório e os demais foram operados sem assistência circulatória (grupo controle. Os dois grupos de pacientes tinham características semelhantes quanto a fatores associados aos desfechos em questão. Ocorreram 5 (8,6% óbitos no grupo com BIAo e 21 (11,6%, no grupo controle (diferença não-signifícativa. Ocorreram 2 (3,4% infartos no grupo com BIAo e 28 (15,5%, no grupo controle BIAo (p OBJECTIVE: To evaluate the effectiveness of prophylactic intra-aortic balloon (IAB in elective myocardial revascularization surgery (MRS, to prevent trans or post-operative infarction and reduce intra-hospital mortality in patients with low left ventricular ejection fraction. METHODS: Using a cohort study model, 239 patients with left ventricular ejection fraction <40%, submitted to elective MRS with extracorporeal circulation (ECC were evaluated from March 1995 to February 2001. RESULTS: Of these, 58 patients received preoperative IAB and the remainder underwent surgery without circulatory assistance (control group. The two groups of patients had similar characteristics regarding factors associated to the pertaining outcomes. There were five demises (8.6% in the group with IAB and 21 (11.6% in the control group (non-significant difference. There were 2 (3.4% infarctions in the IAB group and 28 (15.5% in the control group (p< 0

  6. Penis Pump

    Science.gov (United States)

    ... your appointment might be less involved. Choosing a penis pump Some penis pumps are available without a ... it doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines ...

  7. Balloon launching station, Mildura, Victoria

    International Nuclear Information System (INIS)

    The Mildura Balloon Launching Station was established in 1960 by the Department of Supply (now the Department of Manufacturing Industry) on behalf of the United States Atomic Energy Commission (USAEC) to determine the content of radioactive material in the upper atmosphere over Australia. The Station location and layout, staffing, balloon launching equipment, launching, tracking and recovery are described. (R.L.)

  8. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  9. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, F.A.B.; Spithoven, J.H.; Zeebregts, C.J.A.; Scharn, D.M.; Reijnen, M.M.

    2015-01-01

    PURPOSE: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. MATERIALS AND METHODS: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  10. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, Frederike A. B.; Spithoven, J. Hans; Zeebregts, Clark J.; Scharn, Dirk M.; Reijnen, Michel M. P. J.

    Purpose: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. Materials and Methods: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  11. Different transcatheter strategies for aortic coarctation associated with patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2012-07-01

    Conclusions: In coarctation with patent ductus arteriosus associated with good sized aortic isthmus, closure of duct with duct occluder device and balloon aortoplasty would correct the lesions. If there is isthmic hypoplasia, device closure of the duct and stenting of the coarctation is needed. Covered stent is a reasonable alternative only in presence of non dilated descending aorta.

  12. Off-Pump Repair of a Post Myocardial Infarction Ventricular Septal Defect

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2014-01-01

    Full Text Available Refractory cardiogenic shock meant that traditional patch repairs requiring cardiopulmonary bypass would be poorly tolerated and external sandwich closure of post myocardial ventricular septal defect (VSD appears to be simple and effective after initial myocardial infarction (MI. The three cases presented with a VSD after of acute MI with or without thrombolysed with streptokinase during patient admission. The general condition of the three patients was poor with pulmonary edema, low cardiac output and renal failure. The heart was approached through a median sternotomy. Off-pump coronary artery bypass grafting of the coronary artery lesion was done first using octopus and beating heart surgery method and latero - lateral septal plication was performed using sandwich technique. Low cardiac output managed with intra-aortic balloon pump in these patients accompanied with inotropic drugs. Post-operative transesophageal echocardiography revealed that VSD was closed completely in one patient and in two patients small residual VSD remained. More experience is required to ascertain whether this technique will become an accepted alternative to patch repairs.

  13. Clinical efficacy of transcatheter aortic valve replacement for severe aortic stenosis in high-risk patients: the PREVAIL JAPAN trial.

    Science.gov (United States)

    Sawa, Yoshiki; Takayama, Morimasa; Mitsudo, Kazuaki; Nanto, Shinsuke; Takanashi, Shuichiro; Komiya, Tatsuhiko; Kuratani, Toru; Tobaru, Tetsuya; Goto, Tsuyoshi

    2015-01-01

    Transcatheter aortic valve replacement (TAVR) is suggested to be less invasive and/or equally effective in comparison to conventional aortic valve replacement for high-risk symptomatic aortic stenosis patients. We herein report the initial results of a pivotal clinical trial of TAVR in Japan (the PREVAIL JAPAN). Sixty-four aortic stenosis patients (mean age 84.3 ± 6.1 years) not suitable for surgery were enrolled at three centers in Japan, with a primary composite endpoint of the 6-month post-procedure improvements in the aortic valve area and New York Heart Association (NYHA) functional classification. A transfemoral approach was used in 37 patients and a transapical approach was used in 27. The device success rate was 91.9 %. After 30 days and 6 months, the rates of mortality from any cause were 8.1 and 11.3 %, respectively. At 6 months, symptomatic stroke was found in 3.1 % of the patients, and silent infarction in 7.8 %. The aortic valve area and mean pressure gradient were significantly improved over time with both approaches (p < 0.001). At 6 months, the NYHA functional classification based on a conventional physician's assessment was improved in 87.9 % of the patients. We found results that were equivalent to those in other major TAVR trials, such as an acceptable 30-day survival (91.9 %), suggesting that balloon-expandable TAVR is effective for small Japanese AS patients classified as high-risk or inoperable.

  14. Análise dos resultados imediatos da cirurgia de revascularização do miocárdio com e sem circulação extracorpórea Analysis of immediate results of on-pump versus off-pump coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Marcos Antonio Cantero

    2012-03-01

    number of grafts per patient was 2.48 ± 0.43 in off-pump group and 2.90 ± 0.59 in on-pump group. In the off-pump group, 97.8% of patients received an internal thoracic artery graft, while on-pump group the percentage was 94.1% (P = 0.03. The rate of complete revascularization was similar in both groups. In off-pump group, the circumflex artery was revascularized in 48.9% and 68.2% in the onpump group (P = 0.01. Hospital mortality was 4.3% and 4.7%, respectively in the off-pump group in the on-pump group (P = 0.92. Off-pump group had fewer complications in relation to perioperative myocardial infarction (P = 0.02 and use of intra-aortic balloon pump (P = 0.01. CONCLUSION: The off-pump CABG is a safe procedure with hospital mortality similar to that observed in on-pump CABG, with lower rates of complications and less need for intra-aortic balloon.

  15. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  16. 21 CFR 874.4100 - Epistaxis balloon.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Epistaxis balloon. 874.4100 Section 874.4100 Food... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4100 Epistaxis balloon. (a) Identification. An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal...

  17. Calculating Payload for a Tethered Balloon System

    Science.gov (United States)

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  18. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2).

    Science.gov (United States)

    Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger

    2011-07-01

    This study sought to review the acute procedural outcomes of patients who underwent transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation at the German Heart Center, Munich, and to summarize the existing literature on TAV-in-SAV implantation (n = 47). There are several case reports and small case series describing transcatheter aortic valve implantation for a failing surgical aortic valve bioprosthesis (TAV-in-SAV implantation). From January 2007 to March 2011, 20 out of 556 patients underwent a TAV-in-SAV implantation at the German Heart Center Munich. Baseline characteristics and clinical outcome data were prospectively entered into a dedicated database. The mean patient age was 75 ± 13 years, and the mean logistic European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons' Risk Model scores were 27 ± 13% and 7 ± 4%, respectively. Of the 20 patients, 14 had stented and 6 had stentless surgical bioprostheses. Most cases (12 of 20) were performed via the transapical route using a 23-mm Edwards Sapien prosthesis (Edwards Lifesciences, Irvine, California). Successful implantation of a TAV in a SAV with the patient leaving the catheterization laboratory alive was achieved in 18 of 20 patients. The mean transaortic valve gradient was 20.0 ± 7.5 mm Hg. None-to-trivial, mild, and mild-to-moderate paravalvular aortic regurgitation was observed in 10, 6, and 2 patients, respectively. We experienced 1 intraprocedural death following pre-implant balloon aortic valvuloplasty ("stone heart") and 2 further in-hospital deaths due to myocardial infarction. TAV-in-SAV implantation is a safe and feasible treatment for high-risk patients with failing aortic bioprosthetic valves and should be considered as part of the armamentarium in the treatment of aortic bioprosthetic valve failure. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. US Daily Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Pilot Balloon observational forms for the United States. Taken by Weather Bureau and U.S. Army observers. Period of record 1918-1960. Records scanned from the NCDC...

  20. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  1. Anderson localization and ballooning eigenfunctions

    International Nuclear Information System (INIS)

    Dewar, R.L.; Cuthbert, P.

    1999-01-01

    In solving the ballooning eigenvalue for a low-aspect-ratio stellarator equilibrium it is found that the quasiperiodic behaviour of the equilibrium quantities along a typical magnetic field line can lead to localization of the ballooning eigenfunction (Anderson localization) even in the limit of zero shear. This localization leads to strong field-line dependence of the ballooning eigenvalue, with different branches attaining their maximum growth rates on different field lines. A method is presented of estimating the field-line dependence of various eigenvalue branches by using toroidal and poloidal symmetry operations on the shear-free ballooning equation to generate an approximate set of eigenfunctions. These zero-shear predictions are compared with accurate numerical solutions for the H-1 Heliac and are shown to give a qualitatively correct picture, but finite shear corrections will be needed to give quantitative predictions

  2. Solar research with stratospheric balloons

    Science.gov (United States)

    Vázquez, Manuel; Wittmann, Axel D.

    Balloons, driven by hot air or some gas lighter than air, were the first artificial machines able to lift payloads (including humans) from the ground. After some pioneering flights the study of the physical properties of the terrestrial atmosphere constituted the first scientific target. A bit later astronomers realized that the turbulence of the atmospheric layers above their ground-based telescopes deteriorated the image quality, and that balloons were an appropriate means to overcome, total or partially, this problem. Some of the most highly-resolved photographs and spectrograms of the sun during the 20th century were actually obtained by balloon-borne telescopes from the stratosphere. Some more recent projects of solar balloon astronomy will also be described.

  3. Retrieving Balloon Data in Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Ultra Long Duration Balloon (ULDB) program will soon make flights lasting up to 100 days. Some flights may generate high data rates and retrieving this data...

  4. Percutaneous balloon valvuloplasty in mitral stenosis

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Oh, Byung Hee; Park, Kyung Ju; Kim, Seung Hyup; Lee, Young Woo; Han, Man Chung

    1989-01-01

    Percutaneous balloon valvuloplasty(PBV) was successfully performed in 8 mitral stenosis patients for recent 3 months. Five patients have aortic insufficiencies also and two patients have mitral regurgitations below grade II/IV. All patients showed sinus rhythm on EKG, and had no mitral valvular calcification on echocardiography and fluoroscopy. PBV resulted in an increase in mitral valve area from 1.22±0.22 to 2.57±0.86 cm 2 , a decrease in mean left atrial pressure from 23.4±9.6 to 7.5±3.4 mmHg and a decrease in mean mitral pressure gradient from 21.3±9.4 to 6.8±3.1 mmHg. There were no significant complications except 2 cases of newly appeared and mildly aggravated mitral regurgitation. We believe that PBV will become a treatment modality of choice replacing surgical commissurotomy or valve replacement in a group of mitral stenosis patients, because of its effectiveness and safety

  5. [Application of temporary balloon blocking technique in bone tumors surgery under the aid of CT angiography].

    Science.gov (United States)

    Fang, Cheng; Hu, Yongcheng; Huang, Hongchao; Xia, Qun; Chen, Xiaopeng; Yuan, Binbin; He, Xin; Wang, Peng

    2014-10-01

    To study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. A retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. The CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545 ± 0.248) cm and (1.060 ± 0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818 ± 1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months

  6. Pioneering Space Research with Balloons

    Science.gov (United States)

    Jones, W. V.

    NASA s Scientific Ballooning Planning Team has concluded that ballooning enables significant scientific discoveries while providing test beds for space instruments and training for young scientists Circumpolar flights around Antarctica have been spectacularly successful with fight durations up to 42 days Demand for participation in this Long-Duration Balloon LDB program a partnership with the U S National Science Foundation Office of Polar Programs is greater than the current capacity of two flights per campaign Given appropriate international agreements LDB flights in the Northern Hemisphere would be competitive with Antarctic flights and super-pressure balloons would allow comparable flights at any latitude The Balloon Planning Team made several recommendations for LDB flights provide a reliable funding source for sophisticated payloads extend the Antarctic capability to three flights per year and develop a comparable capability in the Arctic provide aircraft for intact-payload recovery develop a modest trajectory modification capability to enable longer flights and enhance super-pressure balloons to carry 1-ton payloads to 38 km Implementation of these recommendations would facilitate frequent access to near-space for cutting-edge research and technology development for a wide range of investigations

  7. A new approach to the diagnosis of esophageal rupture due to balloon dilatation

    International Nuclear Information System (INIS)

    Song, Ho Young; Han, Young Min; Lee, Sang Young; Kuh, Ja Hong; Lee, Dong Kun; Chae, Soo Wan

    1990-01-01

    The diagnosis of esophageal rupture in balloon dilatation is usually made from clinical symptom of sharp chest pain, plain chest radiographs and esophagograms after dilation. It has some problems; the pain is varied patients to patients and bacterial flora in the mouth or esophagus can be mixed with the contrast media to flow into the mediastinum during esophagography, to create mediastinitis. We could make the diagnosis of esophageal rupture without using contrast media by the observation of the pressure change in the balloon during dilatation. An infusion pump, transducer and esophageal balloon were connected through a multi-way connector, and the transducer of them was also connected to an amplifier which was connected to a pressure monitor to record the balloon pressure. As balloon(20mm/3cm) inserted in the mid-thoracic esophagus under the fluoroscopic control was inflated until the esophagus was ruptured. Balloon was distended by injecting air in 15 rabbits(A group), and by injecting diluted contrast medium in 15 rabbits(B group). The pressure decrease after esophageal rupture was ranged from 94 to 160 mmHg(mean; 103) in A group and 340 to 1040 mmHg(mean; 537) in B group. The pressure curve of A group was smooth, regular and so accurate to make the diagnosis of esophageal rupture, whereas that of B group was irregular and not so accurate. In conclusion, our new method to make the diagnosis of esophageal rupture during balloon dilatation may be useful in patients of esophageal stricture

  8. Under Pressure: Activities with a Vacuum Pump (and Some Marshmallows) Help Students Learn about Pressure.

    Science.gov (United States)

    Galus, Pamela

    2002-01-01

    Introduces a science demonstration that illustrates the effects of pressure and gravity on humans using a marshmallow man and a vacuum pump. Demonstrates the same concept with shaving cream, balloons, and boiling water without raising temperature. (YDS)

  9. Aortic arch malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kellenberger, Christian J. [University Children' s Hospital, Department of Diagnostic Imaging, Zuerich (Switzerland)

    2010-06-15

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  10. Imaging in aortic dissection

    International Nuclear Information System (INIS)

    Yu-Qing Liu, M.D.

    1995-01-01

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.)

  11. Aortic arch malformations

    International Nuclear Information System (INIS)

    Kellenberger, Christian J.

    2010-01-01

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  12. Imaging in aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Qing Liu, M D [Chinese Academy of Medical Sciences, Beijing, BJ (China). Dept. of Radiology, Fu Wai Hospital and Cardiovascular Inst.

    1996-12-31

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.).

  13. Aortic intracardiac echocardiography-guided septal puncture during mitral valvuloplasty.

    Science.gov (United States)

    Akkaya, Emre; Vuruskan, Ertan; Zorlu, Ali; Sincer, Isa; Kucukosmanoglu, Mehmet; Ardic, Idris; Yilmaz, Mehmet Birhan

    2014-01-01

    Transoesophageal echocardiography (TEE) and venous intracardiac echocardiography (ICE) are traditionally used to visualize the interatrial septum (IAS) and the tenting effect of the fossa ovalis in patients undergoing percutaneous balloon mitral valvuloplasty (PBMV). The aim of the present study was to assess the comparative efficacy and safety of arterial (intra-aortic) ICE and venous ICE, compared with TEE (traditional approach), in the patients undergoing PBMV. TEE, aortic ICE, and venous ICE were consecutively performed in 50 patients (40 ± 9 years, 86% female). The images of intracardiac structures were obtained from both aortic and right atrial loci. The IAS was visualized using TEE, aortic ICE, and venous ICE. The mean mitral valve area was 1.14 ± 0.2 cm(2), and the mean left atrial volume index was 57.5 ± 12 mL/m(2). The mean size of the visualized septal length was 48 ± 5 mm by TEE, 51 ± 5 mm by aortic ICE, and 33 ± 6 mm by venous ICE. The Bland-Altman test indicated that the 95% limits of agreement for the measurement of septal diameter ranged from -11.0 to +5.9 mm (mean -2.5 mm) between TEE and aortic ICE, -2.8 to +33.5 mm (mean +15.3 mm) between TEE and venous ICE, and -36.6 to +0.8 mm (mean -17.9 mm) between venous and aortic ICE. Standard venous ICE generally tended to yield smaller values compared with TEE and aortic ICE for the measurement of septal length. Furthermore, the view of fossa ovalis and 'tenting effect' was optimal in 11 patients on venous ICE; however, the fossa ovalis and tip of the needle were well visualized in all patients on aortic ICE (P < 0.001). There were no major complications with the use of aortic ICE. Aortic ICE is a superior alternative to venous ICE and facilitates trans-septal puncture in patients with mitral stenosis.

  14. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  15. Comparative in vivo analysis of the role of the adventitia and the endothelium on arterial mechanical function: relevance for aortic counterpulsation.

    Science.gov (United States)

    Bia, Daniel; Zócalo, Yanina; Wray, Sandra; Cabrera-Fischer, Edmundo I

    2017-06-09

    The comparative effect of the intimal and adventitial layers on arterial biomechanics control, in basal and altered conditions, remains to be elucidated. This study aimed (1) to characterize the arterial conduit (CF) and buffering (distensibility) function of the iliac arteries in in vivo animals, in which the intimal and adventitial layers were removed; (2) to determine the effects of intra-aortic ballon pumping (IABP) on simultaneously de-adventitialized (DA) and de-endothelialized (DE) iliac arteries before and after induced heart failure. Pressure and diameter signals were measured in the iliac arteries of sheep (n = 7) in which the adventitial and intima layer were removed. Intra-aortic balloon pump (IABP) assistance was used in a control state and after heart failure induction. Both DE and DA determined significant changes in arterial diameter, distensibility and CF. Changes were higher after DA than after DE in terms of distensibility and CF (p<0.05). DA followed by DE (DA + DE) showed significant increases in arterial diameter and CF, accompanied by a decrease in distensibility (p<0.05) with respect to intact arteries. Heart failure induction caused significant hemodynamic changes without modifying the already impaired local biomechanical parameters. Nonsignificant improvements in the biomechanical parameters of DA + DE iliac arteries were observed during IABP before and after heart failure induction. Biomechanical changes caused by DA of iliac arteries were more important than those observed after DE. The DA + DE arteries showed significant differences with respect to intact arteries and with DA or DE arteries. IABP-related effects on arterial mechanics were absent in DA + DE arteries.

  16. Bovine aortic arch with supravalvular aortic stenosis.

    Science.gov (United States)

    Idhrees, Mohammed; Cherian, Vijay Thomas; Menon, Sabarinath; Mathew, Thomas; Dharan, Baiju S; Jayakumar, K

    2016-09-01

    A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS). On evaluation of CT angiogram, there was associated bovine aortic arch (BAA). Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  17. Bovine aortic arch with supravalvular aortic stenosis

    Directory of Open Access Journals (Sweden)

    Mohammed Idhrees

    2016-09-01

    Full Text Available A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS. On evaluation of CT angiogram, there was associated bovine aortic arch (BAA. Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA.

  18. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  19. Balloon pulmonary valvotomy – Not just a simple balloon dilatation

    Directory of Open Access Journals (Sweden)

    Subhendu Mohanty

    2014-07-01

    Full Text Available Balloon pulmonary valvotomy is the preferred mode of treatment in patients with isolated pulmonary valvar stenosis and has shown good long term results. It is generally considered a safe procedure with few complications. There have been however, case reports of potentially fatal acute severe pulmonary edema occurring after the procedure in some patients. The cause of this complication and its pathophysiology is still not clear. Its occurrence is also infrequent with less than 5 cases reported till now. We report a case of pulmonary valvar stenosis which developed acute severe refractory pulmonary edema immediately after balloon pulmonary valvotomy.

  20. Rapid Two-stage Versus One-stage Surgical Repair of Interrupted Aortic Arch with Ventricular Septal Defect in Neonates

    Directory of Open Access Journals (Sweden)

    Meng-Lin Lee

    2008-11-01

    Conclusion: The outcome of rapid two-stage repair is comparable to that of one-stage repair. Rapid two-stage repair has the advantages of significantly shorter cardiopulmonary bypass duration and AXC time, and avoids deep hypothermic circulatory arrest. LVOTO remains an unresolved issue, and postoperative aortic arch restenosis can be dilated effectively by percutaneous balloon angioplasty.

  1. Balloon dilatation of ureteric strictures.

    Directory of Open Access Journals (Sweden)

    Punekar S

    2000-01-01

    Full Text Available AIMS: Evaluation of dilatation as a minimally invasive technique for the treatment of ureteric strictures. MATERIAL AND METHODS: We evaluated this technique in 16 patients with ureteric and secondary pelviureteric junction strictures from June 1998. Of these, 7 were men and 9 were women. The age range was from 14 to 40 years. RESULTS: Balloon dilatation was successful in 69% of patients. Strictures secondary to previous surgery had nearly 100% success. Of the 8 cases diagnosed as genitourinary tuberculosis, success rate was 50%. CONCLUSIONS: Factors affecting success of balloon dilatation are: a age of the stricture b length of the stricture and c etiology of the stricture. In a select group of patients with fresh post-operative or post-inflammatory strictures, balloon dilatation may be an attractive alternative to surgery.

  2. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  3. Mars Solar Balloon Lander, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  4. Taking the Hot Air Out of Balloons.

    Science.gov (United States)

    Brinks, Virgil L.; Brinks, Robyn L.

    1994-01-01

    Describes how a teacher can give their students the challenge of designing and building model balloons or blimps. The project helps students learn the basics of balloon flight and what it really means to be "lighter than air." (PR)

  5. Application of new balloon catheters in the treatment of congenital heart defects

    Directory of Open Access Journals (Sweden)

    Roland Fiszer

    2016-08-01

    Full Text Available Introduction : Balloon angioplasty (BAP and aortic or pulmonary balloon valvuloplasty (BAV, BPV are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim: To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland launched and developed. These catheters have not been clinically evaluated yet. Material and methods: We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF, 10 BAV and 27 BAP in coarctations of the aorta (CoA – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations, 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results: All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean, BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin. No such complication occured with Valver II. Conclusions : Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses.

  6. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  7. Scientific Ballooning in India - Recent Developments

    Science.gov (United States)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  8. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    Science.gov (United States)

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  9. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  10. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  11. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  12. Traumatic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Brianna Miner

    2016-09-01

    Full Text Available History of present illness: A 48-year-old male with unknown past medical history presents as a trauma after being hit by a car traveling approximately 25 miles per hour. On initial presentation, the patient is confused, combative, and not answering questions appropriately. The patient is hypotensive with a blood pressure of 68/40 and a heart rate of 50 beats per minute, with oxygen saturation at 96% on room air. FAST scan is positive for fluid in Morrison’s pouch, splenorenal space, and pericardial space. Significant findings: The initial chest x-ray showed an abnormal superior mediastinal contour (blue line, suggestive of a possible aortic injury. The CT angiogram showed extensive circumferential irregularity and outpouching of the distal aortic arch (red arrows compatible with aortic transection. In addition, there was a circumferential intramural hematoma, which extended through the descending aorta to the proximal infrarenal abdominal aorta (green arrow. There was also an extensive surrounding mediastinal hematoma extending around the descending aorta and supraaortic branches (purple arrows. Discussion: Traumatic aortic injury is a life-threatening event. The incidence of blunt thoracic aortic injury is low, between 1 to 2 percent of those patients with blunt thoracic trauma.1 However, approximately 80% of patients with traumatic aortic injury die at the scene.2 Therefore it is imperative to diagnose traumatic aortic injury in a timely fashion. The diagnosis can be difficult due to the non-specific signs and symptoms and other distracting injuries. Clinical suspicion should be based on the mechanism of the injury and the hemodynamic status of the patient. In any patient with blunt or penetrating trauma to the chest that is hemodynamically unstable, traumatic aortic injury should be on the differential. Chest x-ray can be used as a screening tool. A normal chest x-ray has a negative predictive value of approximately 97%. CTA chest is the

  13. The development of coastal diffusion observation method with a captive balloon

    International Nuclear Information System (INIS)

    Fukuda, Masaaki; Yamada, Masaharu

    1980-03-01

    Apparatus whereby the dye cloud in a coastal area in diffusion experiment can be photographed was developed. It consists of a vinyl balloon two meters in diameter, a photographic device with the camera shutter released by wireless signals from the ground, and a winch to raise or lower the balloon. A maximum height of the balloon for taking photographs is 1000 m. During the single balloon flight, thirty photographs can be taken. With the balloon at a certain height, dye as the tracer in diffusion experiment is released at sea surface or a certain sea depth by dye-throwing means or pump, and then taking the photographs is started. Movement and diffusion of the dye are analyzed by means of the photographs taken. The apparatus is simple in mechanism and easy to transport. Dye experiment is possible in the surfe zone where a boat cannot enter. It is impossible, however, to raise the balloon in strong wind or sea breeze. Typical results of the dye diffusion experiment with the apparatus are given. (author)

  14. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  15. Laser welding of balloon catheters

    Science.gov (United States)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  16. Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.

    Science.gov (United States)

    Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas

    2011-12-01

    As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Three-year-old child with middle aortic syndrome treated by endovascular stent implantation.

    Science.gov (United States)

    Moszura, Tomasz; Goreczny, Sebastian; Dryzek, Pawel; Niwald, Marek

    2013-04-01

    Middle aortic syndrome (MAS) is an extremely rare anomaly and represents both a diagnostic and therapeutic challenge, particularly in young children. A case of a 3.5 year-old child with MAS and arterial hypertension is reported, where owing to the patient's young age and the length of the hypoplastic aortic segment, surgical correction with end-to-end anastomosis was not feasible. Instead of palliative bypass grafting between the thoracic and abdominal aorta, successful percutaneous balloon angioplasty and stenting of the lesion was performed with the assistance of three-dimensional rotational angiography.

  18. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  19. Valvoplastia aórtica por cateter-balão em emergência materno-fetal na adolescência Valvuloplastia aórtica por catéter con balón en emergencia materno-fetal en la adolescencia Aortic valvuloplasty with balloon catheter in maternal-fetal emergency in adolescence

    Directory of Open Access Journals (Sweden)

    Walkiria Samuel Avila

    2009-12-01

    Full Text Available O aumento do débito cardíaco durante a gravidez é causa de insuficiência cardíaca em portadoras de estenose valvar aórtica grave. A valvoplastia aórtica percutânea tem sido associada a graves complicações e reestenose valvar em curto prazo. O presente caso mostrou que a valvoplastia aórtica percutânea permitiu o alcance do parto com sobrevida da mãe e do feto, e que a interrupção do tratamento no pós-parto resultou em morte materna no puerpério tardio.El aumento del gasto cardiaco durante el embarazo es la causa de insuficiencia cardiaca en portadoras de estenosis valvular aórtica severa. Se viene asociando la valvuloplastia aórtica percutánea a severas complicaciones y reestenosis valvular en corto plazo. El presente caso reveló que la valvuloplastia aórtica percutánea permitió el alcance del parto con sobrevida de la madre y del feto, y que la interrupción del tratamiento en el postparto resultó en muerte materna en el puerperio tardío.The increase of cardiac output during pregnancy is the cause of heart failure in women with severe aortic valvular stenosis. Percutaneous aortic valvuloplasty has been associated with severe complications and short-term valvar restenosis. This case showed that percutaneous aortic valvuloplasty allowed both mother and fetus to survive after childbirth, and that postpartum treatment interruption resulted in maternal death in late postpartum care.

  20. Status of the NASA Balloon Program

    Science.gov (United States)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  1. Scientific ballooning in India Recent developments

    Science.gov (United States)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  2. Impact of around-the-clock in-house cardiology fellow coverage on door-to-balloon time in an academic medical center

    Directory of Open Access Journals (Sweden)

    Kohan LC

    2017-04-01

    Full Text Available Luke C Kohan,1,* Vijaiganesh Nagarajan,1,* Michael A Millard,2 Michael J Loguidice,2 Nancy M Fauber,1 Ellen C Keeley1 1Division of Cardiology, 2Department of Medicine, University of Virginia, Charlottesville, VA, USA * These authors contributed equally to this work Objectives: To assess if a change in our cardiology fellowship program impacted our ST elevation myocardial infarction (STEMI program. Background: Fellows covering the cardiac care unit were spending excessive hours in the hospital while on call, resulting in increased duty hours violations. A night float fellow system was started on July 1, 2012, allowing the cardiac care unit fellow to sign out to a night float fellow at 5:30 pm. The night float fellow remained in-house until the morning. Methods: We performed a retrospective study assessing symptom onset to arrival, arterial access to first device, and door-to-balloon (D2B times, in consecutive STEMI patients presenting to our emergency department before and after initiation of the night float fellow system. Results: From 2009 to 2013, 208 STEMI patients presented to our emergency department and underwent primary percutaneous coronary intervention. There was no difference in symptom onset to arrival (150±102 minutes vs 154±122 minutes, p=0.758, arterial access to first device (12±8 minutes vs 11±7 minutes, p=0.230, or D2B times (50±32 minutes vs 52±34 minutes, p=0.681 during regular working hours. However, there was a significant decrease in D2B times seen during off-hours (72±33 minutes vs 49±15 minutes, p=0.007. There was no difference in in-hospital mortality (11% vs 8%, p=0.484 or need for intra-aortic balloon pump placement (7% vs 8%, p=0.793. Conclusion: In academic medical centers, in-house cardiology fellow coverage during off-hours may expedite care of STEMI patients. Keywords: door-to-balloon time, 24/7 in-house call, cardiology fellow

  3. The impact of aortic manipulation on neurologic outcomes after coronary artery bypass surgery: a risk-adjusted study.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Stamou, Sotiris C; Dullum, Mercedes K C; Hill, Peter C; Haile, Elizabeth; Boyce, Steven W; Bafi, Ammar S; Petro, Kathleen R; Corso, Paul J

    2004-11-01

    Cerebral embolization of atherosclerotic plaque debris caused by aortic manipulation during conventional coronary artery bypass grafting (CABG) is a major mechanism of postoperative cerebrovascular accidents (CVA). Off-pump CABG (OPCABG) reduces stroke rates by minimizing aortic manipulation. Consequently, the effect of different levels of aortic manipulation on neurologic outcomes after CABG surgery was examined. From January 1998 to June 2002, 7,272 patients underwent isolated CABG surgery through three levels of aortic manipulation: full plus tangential (side-biting) aortic clamp application (on-pump surgery; n = 4,269), only tangential aortic clamp application (OPCABG surgery; n = 2,527) or an "aortic no-touch" technique (OPCABG surgery; n = 476). A risk-adjusted logistic regression analysis was performed to establish the likelihood of postoperative stroke with each technique. Preoperative risk factors for stroke from the literature, and those found significant in a univariable model were used. A significant association for postoperative stroke correspondingly increasing with the extent of aortic manipulation was demonstrated by the univariable analysis (CVA incidence respectively increasing from 0.8% to 1.6% to a maximum of 2.2%, p < 0.01). In the logistic regression model, patients who had a full and a tangential aortic clamp applied were 1.8 times more likely to have a stroke versus those without any aortic manipulation (95% confidence interval: 1.15 to 2.74, p < 0.01) and 1.7 times more likely to develop a postoperative stroke than those with only a tangential aortic clamp applied (95% confidence interval: 1.11 to 2.48, p < 0.01). Aortic manipulation during CABG is a contributing mechanism for postoperative stroke. The incidence of postoperative stroke increases with increased levels of aortic manipulation.

  4. Emergency aortic valve replacement and Caesarian section in a primigravida with severe aortic stenosis: a case report.

    Science.gov (United States)

    Kochhar, Puneet K; Zutshi, V; Shamsunder, S; Batra, S; Ghosh, P

    2011-01-01

    Congenital bicuspid aortic valve with severe aortic stenosis (AS) is a rare condition (3-6% of patients with congenital heart disease). Pregnancy in these patients carries a high risk of maternal and fetal mortality. With advancing gestational age, these women may develop cardiac failure due to increased cardiorespiratory requirements. When medical therapy proves insufficient, cardiac surgery becomes mandatory to save the patient's life. Balloon valvuloplasty is only palliative treatment, the duration of benefit being only 6 months. Valve replacement is thus recommended. Cardiopulmonary bypass (CPB) surgery with valve replacement has been reported to carry a lower risk of maternal mortality (1.5-13%) but a very high fetal risk (16-40%). This paper reports the case of a 30-year-old primigravida with severe AS with bicuspid aortic valve and pulmonary congestion clinically uncontrolled, in whom CPB surgery and aortic valve replacement was performed as an emergency procedure, along with a lower segment Caesarian section. The outcome of unrelieved severe symptomatic AS in pregnancy is poor. Multidisciplinary management is important to avoid deterioration in cardiac performance in parturients with severe AS. CPB during pregnancy carries a high risk to the fetus. Therefore, open heart surgery during pregnancy should be advised only in extreme emergencies (ie, heart failure refractory to conventional therapy).

  5. Aortic valve replacement for aortic stenosis caused by alkaptonuria.

    Science.gov (United States)

    Hiroyoshi, Junko; Saito, Aya; Panthee, Nirmal; Imai, Yasushi; Kawashima, Dai; Motomura, Noboru; Ono, Minoru

    2013-03-01

    We report a case of aortic stenosis associated with ochronosis in a 70-year-old man who underwent biologic aortic valve replacement. Intraoperative findings included ochronosis of a severely calcified pigmented aortic valve along with pigmentation of the intima of the aorta. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    Science.gov (United States)

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing

  7. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  8. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  9. Investigation of hot air balloon fatalities.

    Science.gov (United States)

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  10. PEBS - Positron Electron Balloon Spectrometer

    CERN Document Server

    von Doetinchem, P.; Kirn, T.; Yearwood, G.Roper; Schael, S.

    2007-01-01

    The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was needed to design a detector which could increase the existing data by more than a factor of 100. Using silicon photomultipliers for the readout of a scintillating fiber tracker and of an imaging electromagnetic calorimeter, the PEBS detector features a large geometrical acceptance of 2500 cm^2 sr for positrons, a total weight of 1500 kg and a power consumption of 600 W. The experiment is intended to measure cosmic ray particle spectra for a period of up to 20 days at an altitude of 40 km circulating the North or South Pole. A full Geant 4 simulation of the detector concept has been developed and key elements have been verified in a testbeam in October 2006 at CERN.

  11. Left ventricular apical ballooning syndrome

    International Nuclear Information System (INIS)

    Rahman, N.; Tai, J.; Soofi, A.

    2007-01-01

    The transient left ventricular apical ballooning syndrome, also known as Takotsubo cardiomyopathy, is characterized by transient left ventricular dysfunction in the absence of obstructive epicardial coronary disease. Although the syndrome has been reported in Japan since 1990, it is rare in other regions. Rapid recognition of the syndrome can modify the diagnostic and therapeutic attitude i.e. avoiding thrombolysis and performing catheterization in the acute phase. (author)

  12. Effect of milrinone on short term outcome of patients with myocardial dysfunction undergoing off-pump coronary artery bypass graft: a randomized clinical trial.

    Directory of Open Access Journals (Sweden)

    Mehdi Hadadzadeh

    2013-10-01

    Full Text Available Myocardial dysfunction is a major complication in cardiac surgery that needs inotropic support. This study evaluates the effect of milrinone on patients with low ventricular ejection fraction undergoing off- pump coronary artery bypass graft (OPCAB. The present study is designed to evaluate the effect of milrinone on myocardial dysfunction. Eighty patients with low ventricular ejection fraction (<35%, candidate for elective OPCAB, were enrolled in this study. They were randomly assigned to two groups. One group received milrinone (50 μg/kg intravenously and another group received a saline as placebo followed by 24 hours infusion of each agent (0.5 μg/kg/min. Short outcome of patients such as hemodynamic parameters and left ventricular ejection fraction were variables evaluated. Serum levels of creatine phosphokinase, the MB isoenzyme of creatine kinase, occurrence of arrhythmias and mean duration of mechanical ventilation were significantly lower in milrinone group (P<0.05. The mean post operative left ventricular ejection fraction was significantly higher in milrinone group (P=0.031. There were no statistical significant differences between the two groups in terms of intra-aortic balloon pump, inotropic support requirement, myocardial ischemia, myocardial infarction, duration of inotropic support, duration of intensive care unit stay, mortality and morbidity rate. Administration of milrinone in patients undergoing OPCAB with low ventricular ejection fraction is useful and effective.

  13. Effect of milrinone on short term outcome of patients with myocardial dysfunction undergoing off-pump coronary artery bypass graft: a randomized clinical trial.

    Science.gov (United States)

    Hadadzadeh, Mehdi; Hosseini, Seyed Habib; Mostafavi Pour Manshadi, Seyed Mohammad Yousof; Naderi, Nafiseh; Emami Meybodi, Mahmood

    2013-01-01

    Myocardial dysfunction is a major complication in cardiac surgery that needs inotropic support. This study evaluates the effect of milrinone on patients with low ventricular ejection fraction undergoing off- pump coronary artery bypass graft (OPCAB). The present study is designed to evaluate the effect of milrinone on myocardial dysfunction. Eighty patients with low ventricular ejection fraction (milrinone (50 μg/kg) intravenously and another group received a saline as placebo followed by 24 hours infusion of each agent (0.5 μg/kg/min). Short outcome of patients such as hemodynamic parameters and left ventricular ejection fraction were variables evaluated. Serum levels of creatine phosphokinase, the MB isoenzyme of creatine kinase, occurrence of arrhythmias and mean duration of mechanical ventilation were significantly lower in milrinone group (P<0.05). The mean post operative left ventricular ejection fraction was significantly higher in milrinone group (P=0.031). There were no statistical significant differences between the two groups in terms of intra-aortic balloon pump, inotropic support requirement, myocardial ischemia, myocardial infarction, duration of inotropic support, duration of intensive care unit stay, mortality and morbidity rate. Administration of milrinone in patients undergoing OPCAB with low ventricular ejection fraction is useful and effective.

  14. Robotic aortic surgery.

    Science.gov (United States)

    Duran, Cassidy; Kashef, Elika; El-Sayed, Hosam F; Bismuth, Jean

    2011-01-01

    Surgical robotics was first utilized to facilitate neurosurgical biopsies in 1985, and it has since found application in orthopedics, urology, gynecology, and cardiothoracic, general, and vascular surgery. Surgical assistance systems provide intelligent, versatile tools that augment the physician's ability to treat patients by eliminating hand tremor and enabling dexterous operation inside the patient's body. Surgical robotics systems have enabled surgeons to treat otherwise untreatable conditions while also reducing morbidity and error rates, shortening operative times, reducing radiation exposure, and improving overall workflow. These capabilities have begun to be realized in two important realms of aortic vascular surgery, namely, flexible robotics for exclusion of complex aortic aneurysms using branched endografts, and robot-assisted laparoscopic aortic surgery for occlusive and aneurysmal disease.

  15. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  16. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  17. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    Science.gov (United States)

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  18. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  19. Abdominal cavity balloon for preventing a patient's bleeding

    OpenAIRE

    Naber, E.E.H.; Rutten, H.J.T.; Jakimowicz, J.J.; Goossens, R.H.M.; Moes, C.C.M.; Buzink, S.N.

    2007-01-01

    The invention relates to an abdominal cavity balloon for preventing a haemorrhage in a patient's pelvic region, comprising an inflatable balloon, wherein the balloon is pro vided with a smooth surface and with a strip that is flex- urally stiff and formed to follow the balloon's shape for po sitioning the balloon.

  20. Electromagnetic pump

    International Nuclear Information System (INIS)

    Ito, Koji; Suetake, Norio; Aizawa, Toshie; Nakasaki, Masayoshi

    1998-01-01

    The present invention provides an electromagnetic pump suitable to a recycling pump for liquid sodium as coolants of an FBR type reactor. Namely, a stator module of the electromagnetic pump of the present invention comprises a plurality of outer laminate iron core units and outer stator modules stacked alternately in the axial direction. With such a constitution, even a long electromagnetic pump having a large number of outer stator coils can be manufactured without damaging electric insulation of the outer stator coils. In addition, the inner circumferential surface of the outer laminate iron cores is urged and brought into contact with the outer circumferential surface of the outer duct by an elastic material. With such a constitution, Joule loss heat generated in the outer stator coils and internal heat generated in the outer laminate iron cores can be released to an electroconductive fluid flowing the inner circumference of the outer duct by way of the outer duct. (I.S.)

  1. Electrokinetic pump

    Science.gov (United States)

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  2. Lifting options for stratospheric aerosol geoengineering: advantages of tethered balloon systems.

    Science.gov (United States)

    Davidson, Peter; Burgoyne, Chris; Hunt, Hugh; Causier, Matt

    2012-09-13

    The Royal Society report 'Geoengineering the Climate' identified solar radiation management using albedo-enhancing aerosols injected into the stratosphere as the most affordable and effective option for geoengineering, but did not consider in any detail the options for delivery. This paper provides outline engineering analyses of the options, both for batch-delivery processes, following up on previous work for artillery shells, missiles, aircraft and free-flying balloons, as well as a more lengthy analysis of continuous-delivery systems that require a pipe connected to the ground and supported at a height of 20 km, either by a tower or by a tethered balloon. Towers are shown not to be practical, but a tethered balloon delivery system, with high-pressure pumping, appears to have much lower operating and capital costs than all other delivery options. Instead of transporting sulphuric acid mist precursors, such a system could also be used to transport slurries of high refractive index particles such as coated titanium dioxide. The use of such particles would allow useful experiments on opacity, coagulation and atmospheric chemistry at modest rates so as not to perturb regional or global climatic conditions, thus reducing scale-up risks. Criteria for particle choice are discussed, including the need to minimize or prevent ozone destruction. The paper estimates the time scales and relatively modest costs required if a tethered balloon system were to be introduced in a measured way with testing and development work proceeding over three decades, rather than in an emergency. The manufacture of a tether capable of sustaining the high tensions and internal pressures needed, as well as strong winds, is a significant challenge, as is the development of the necessary pumping and dispersion technologies. The greatest challenge may be the manufacture and launch of very large balloons, but means have been identified to significantly reduce the size of such balloons or aerostats.

  3. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    mortality were collected. Group analysis by patient geographic distribution and by annular diameter of the prosthesis utilized was conducted. Patients with a manufacturer's labeled prosthesis size > or = 21 mm were assigned to the 'large' aortic size subset, while those with a prosthesis size ... differences in the distribution of either gender or BSA. In the multivariable model, south European patients were seven times more likely to receive a smaller-sized aortic valve (OR = 6.5, 95% CI = 4.82-8.83, p

  4. CArbon dioxide surgical field flooding and aortic NO-touch off-pump coronary artery bypass grafting to reduce Neurological injuries after surgical coronary revascularisation (CANON): protocol for a randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms

    Science.gov (United States)

    Szwed, Krzysztof; Pawliszak, Wojciech; Serafin, Zbigniew; Kowalewski, Mariusz; Tomczyk, Remigiusz; Perlinski, Damian; Szwed, Magdalena; Tomaszewska, Marta; Anisimowicz, Lech; Borkowska, Alina

    2017-01-01

    Introduction Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. Methods and analysis In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethics and dissemination Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. Trial registration number NCT03074604; Pre-results. Date and version identifier 10-Mar-2017 Original PMID:28698347

  5. CArbon dioxide surgical field flooding and aortic NO-touch off-pump coronary artery bypass grafting to reduce Neurological injuries after surgical coronary revascularisation (CANON): protocol for a randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms.

    Science.gov (United States)

    Krzysztof, Szwed; Wojciech, Pawliszak; Zbigniew, Serafin; Mariusz, Kowalewski; Remigiusz, Tomczyk; Damian, Perlinski; Magdalena, Szwed; Marta, Tomaszewska; Lech, Anisimowicz; Alina, Borkowska

    2017-07-10

    Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. NCT03074604; Pre-results. 10-Mar-2017 Original. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Updated clinical indications for transcatheter aortic valve implantation in patients with severe aortic stenosis: expert opinion of the Italian Society of Cardiology and GISE.

    Science.gov (United States)

    Indolfi, Ciro; Bartorelli, Antonio L; Berti, Sergio; Golino, Paolo; Esposito, Giovanni; Musumeci, Giuseppe; Petronio, Sonia; Tamburino, Corrado; Tarantini, Giuseppe; Ussia, Gianpaolo; Vassanelli, Corrado; Spaccarotella, Carmen; Violini, Roberto; Mercuro, Giuseppe; Romeo, Francesco

    2018-05-01

    : The introduction of percutaneous treatment of severe aortic stenosis with transcatheter aortic valve implantation (TAVI) remains one of the greatest achievements of interventional cardiology. In fact, TAVI emerged as a better option than either medical therapy or balloon aortic valvuloplasty for patients who cannot undergo surgical aortic valve replacement (SAVR) or are at high surgical risk. Recently, increased operator experience and improved device systems have led to a worldwide trend toward the extension of TAVI to low-risk or intermediate-risk patients. In this expert opinion paper, we first discuss the basic pathophysiology of aortic stenosis in different settings then the key results of recent clinical investigations on TAVI in intermediate-risk aortic stenosis patients are summarized. Particular emphasis is placed on the results of the nordic aortic valve intervention, placement of aortic transcatheter valves (PARTNER) 2 and Surgical Replacement and Transcatheter Aortic Valve Implantation Randomized trials. The PARTNER 2 was the first large randomized trial that evaluated the outcome of TAVI in patients at intermediate risk. The PARTNER 2 data demonstrated that TAVI is a feasible and reasonable alternative to surgery in intermediate-risk patients (Society of Thoracic Surgeons 4-8%), especially if they are elderly or frail. There was a significant interaction between TAVI approach and mortality, with transfemoral TAVI showing superiority over SAVR. Moreover, we examine the complementary results of the recently concluded Surgical Replacement and Transcatheter Aortic Valve Implantation trial. This prospective randomized trial demonstrated that TAVI is comparable with surgery (primary end point 12.6% in the TAVI group vs. 14.0% in the SAVR group) in severe aortic stenosis patients deemed to be at intermediate risk. We review the most relevant clinical evidence deriving from nonrandomized studies and meta-analyses. Altogether, clinical outcome available data

  7. Vertical sounding balloons for stratospheric photochemistry

    Science.gov (United States)

    Pommereau, J. P.

    The use of vertical sounding balloons for stratospheric photochemistry studies is illustrated by the use of a vertical piloted gas balloon for the search of NO2 diurnal variations. It is shown that the use of montgolfieres (hot air balloons) can enhance the vertical sounding technique. Particular attention is given to a sun-heated montgolfiere and to the more sophisticated infrared montgolfiere that is able to perform three to four vertical excursions per day and to remain aloft for weeks or months.

  8. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  9. Ballooning stable high beta tokamak equilibria

    International Nuclear Information System (INIS)

    Tuda, Takashi; Azumi, Masafumi; Kurita, Gen-ichi; Takizuka, Tomonori; Takeda, Tatsuoki

    1981-04-01

    The second stable regime of ballooning modes is numerically studied by using the two-dimensional tokamak transport code with the ballooning stability code. Using the simple FCT heating scheme, we find that the plasma can locally enter this second stable regime. And we obtained equilibria with fairly high beta (β -- 23%) stable against ballooning modes in a whole plasma region, by taking into account of finite thermal diffusion due to unstable ballooning modes. These results show that a tokamak fusion reactor can operate in a high beta state, which is economically favourable. (author)

  10. Titan Balloon Convection Model, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  11. NASA Langley Research Center tethered balloon systems

    Science.gov (United States)

    Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto

    1987-01-01

    The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.

  12. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  13. Double aortic arch

    Science.gov (United States)

    Surgery can be done to fix double aortic arch. The surgeon ties off the smaller branch and separates it from the larger branch. Then the surgeon closes the ends of the aorta with stitches. This relieves pressure on the esophagus and windpipe.

  14. Bicuspid aortic valve

    Science.gov (United States)

    ... aortic disease. In: Otto CM, Bonow RO, eds. Valvular Heart Disease: A Companion to Braunwald’s Heart Disease . 4th ed. ... PA: Elsevier Saunders; 2014:chap 13. Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman’s Cecil ...

  15. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  16. Design and principle of operation of the HeartMate PHP (percutaneous heart pump)

    NARCIS (Netherlands)

    Mieghem, N.M. van; Daemen, J.; Uil, C. den; Dur, O.; Joziasse, L.; Maugenest, A.M.; Fitzgerald, K.; Parker, C.; Muller, P.; Geuns, R.J.M. van

    2018-01-01

    The HeartMate PHP (percutaneous heart pump) is a second-generation transcatheter axial flow circulatory support system. The collapsible catheter pump is inserted through a 14 Fr sheath, deployed across the aortic valve expanding to 24 Fr and able to deliver up to 5 L/min blood flow at minimum

  17. Balloon dilatations of esophageal strictures

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De

    1990-01-01

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used

  18. Balloon dilatations of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Seoul (Korea, Republic of)

    1990-04-15

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used.

  19. GRAINE balloon experiment in 2015

    Directory of Open Access Journals (Sweden)

    Rokujo Hiroki

    2017-01-01

    Full Text Available Observations of cosmic gamma rays are important for studying high energy phenomena in the universe. Since 2008, the Large Area Telescope on the Fermi satellite has surveyed the whole gamma-ray sky in the sub-GeV/GeV energy region, and accumurated a large amount of data. However, observations at the low galactic latitude remains difficult because of a lack of angular resolution, increase of background flux originating from galactic diffuse gamma rays, etc. The Gamma-Ray Astro-Imager with Nuclear Emulsion (GRAINE is a gamma-ray observation project with a new balloon-borne emulsion gamma-ray telescope. Nuclear emulsion is a high-resolution 3D tracking device. It determines the incident angle with 0.1∘ resolution for 1 GeV gamma rays (1.0∘ for 100 MeV, and has linear polarization sensitivity. GRAINE aims at precise observation of gamma-ray sources, especially in the galactic plane, by repeating long-duration balloon flights with large-aperture-area (10 m2 high-resolution emulsion telescopes. In May 2015, we performed a balloon-borne experiment in Alice Springs, Australia, in order to demonstrate the imaging performance of our telescope. The emulsion telescope that has an aperture area of 0.4 m2 was employed in this experiment. It observed the Vela pulsar (the brightest gamma-ray source in the GeV sky at an altitude of 37 km for 6 hours out of the flight duration of 14 hours. In this presentation, we will report the latest results and the status of the GRAINE project.

  20. Fluidic pumps

    International Nuclear Information System (INIS)

    Priestman, G.H.

    1990-01-01

    A fluidic pump has primary and secondary vessels connected by a pipe, a displacement vessel having liquid to be delivered through a pipe via a rectifier provided with a feed tank. A drive unit delivers pressure fluid to a line to raise liquid and compress trapped gas or liquid in the space, including the pipe between the liquids in the two vessels and thus drive liquid out of the displacement vessel. The driving gas is therefore separated by the barrier liquid and the trapped gas or liquid from the liquid to be pumped which liquid could be e.g. radioactive. (author)

  1. Pumped storage

    International Nuclear Information System (INIS)

    Strauss, P.L.

    1991-01-01

    The privately financed 1,000 MW Rocky Point Pumped Storage Project located in central Colorado, USA, will be one of the world's highest head, 2,350 feet reversible pump/turbine projects. The project will offer an economical supply of peaking power and spinning reserve power to Colorado and other southwestern states. This paper describes how the project will be made compatible with the environmental conditions in the project area and the type of terrestrial mitigation measures that are being proposed for those situations where the project impacts the environment, either temporarily or permanently

  2. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Li, Jun; Dong, Lili; Wang, Chunsheng; Shu, Xianhong

    2016-05-01

    Aberrant flow pattern and congenital fragility bestows bicuspid aortic valve (BAV) with a propensity toward ascending aorta dilatation, aneurysm, and dissection. Whether isolated aortic valve replacement (AVR) can prevent further dilatation in BAV ascending aorta and what indicates concurrent aortic intervention in the case of valve operation remain controversial. From June 2006 to January 2009, patients with a BAV who underwent isolated AVR were consecutively included and categorized into aortic insufficiency (BAV-AI, n = 84) and aortic stenosis (n = 112) groups, and another population of patients with a tricuspid aortic valve with aortic insufficiency (n = 149) was also recruited during the same period for comparison of annual aortic dilatation rate and adverse aortic events after isolated AVR. With a median follow-up period of 72 months (interquartile range, 66 to 78 months), ascending aorta dilatation rates were faster in the BAV-AI group than the BAV plus aortic stenosis and tricuspid aortic valve with aortic insufficiency groups (both p regression analysis identified aortic insufficiency (hazard ratio, 3.7; 95% confidence interval, 1.2 to 11.1; p = 0.019) as an independent risk factor for adverse aortic events among patients with BAV in general, whereas preoperative ascending aortic diameter larger than 45 mm (hazard ratio, 13.8; 95% confidence interval, 3.0 to 63.3; p = 0.001) served as a prognostic indicator in the BAV-AI group. An aggressive policy of preventive aortic interventions seemed appropriate in patients with BAV-AI during AVR, and BAV phenotype presenting as either insufficiency or stenosis should be taken into consideration when contemplating optimal surgical strategies for BAV aortopathy. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Wang Haofu; Wang Yuwei; Li Jun; Zhao Zonggang; Qi Sen

    2010-01-01

    Objective: To summarize the clinical experience of perioperative management in performing endovascular abdominal aortic aneurysm repair (EVAR). Methods: EVAR was performed in 22 patients with abdominal aortic aneurysm. The clinical data were retrospectively analyzed. Before treatment the functions of main organs were evaluated and certain measures were adopted in order to protect them. Useful parameters, including the length, diameter, angle and configuration of the proximal and distal aneurysmal neck, the relationship of the aneurysm to aortic branches, the distance from the lowest renal artery to the bifurcation of abdominal aorta, and the quality of access vessels (such as diameter, tortuosity and calcification degree) were determined and assessed with CTA. According to the parameters thus obtained, the suitable stent-graft with ideal diameter and length was selected, and the optimal surgery pattern was employed. Local anesthesia was employed in 20 patients, among them the local anesthesia had to be changed to general anesthesia in one. Epidural anesthesia was carried out in one patient through the surgically-reconstructed iliac artery access,and general anesthesia was employed in one patient who had Stanford type A aortic dissection. The lowest renal artery must be accurately localized before deployment of stent-graft was started. At least one patent internal iliac artery should be reserved when bilateral internal iliac arteries needed to be covered, to be covered by stages or to be reconstructed. After stent-graft placement, angiography must be performed to find out if there was any endoleak and, if any, to determine the type of endoleak and to deal with it properly. Two cases had proximal type I endoleak, so balloon dilation was employed in one and cuff implantation in another one. Distal type I endoleak occurred in one case, but, unfortunately, the iliac artery ruptured when balloon dilation was employed, therefore the patient had to receive vascular repair

  4. Balloon dilatation of iatrogenic urethral strictures

    International Nuclear Information System (INIS)

    Acunas, B.; Acunas, G.; Gokmen, E.; Celik, L.

    1988-01-01

    Balloon dilatation of the urethra was performed in five patients with iatrogenic urethral strictures. The urethral strictures were successfully negotiated and dilated in all patients. Redilatation became necessary in a period ranging from 3 to 10 months. The authors believe that balloon dilatation of the urethra can be safely and successfully performed; the procedure produces minimal trauma and immediate relief of symptoms. (orig.)

  5. Paraplegia following intraaortic balloon circulatory assistance

    Directory of Open Access Journals (Sweden)

    Benício Anderson

    1999-01-01

    Full Text Available Intraaortic balloon counterpulsation is frequently used in patients experiencing severe ventricular dysfunction following maximal drug therapy. However, even with the improvement of percutaneous insertion techniques, the procedure has always been followed by vascular, infectious, and neurological complications. This article describes a case of paraplegia due to intraaortic balloon counterpulsation in the postoperative period of cardiac surgery.

  6. Montgolfiere balloon missions from Mars and Titan

    Science.gov (United States)

    Jones, Jack A.

    2005-01-01

    Montgolfieres, which are balloons that are filled with heated ambient atmospheric gas, appear promising for the exploration of Mars as well as of Saturn's moon, Titan. On Earth, Montgolfieres are also known as 'hot air balloons'. Commercial versions are typically heated by burning propane, although a number of radiant and solar-heated Montgolfieres have been flown on earth by CNES.

  7. Chimney Technique in Supra-Aortic Branch Reconstruction in China: A Systematic and Critical Review of Chinese Published Experience.

    Science.gov (United States)

    Zhao, Yang; Shi, Yawei; Wang, Mian; Cui, Jin; Chen, Yitian; Zheng, Liang; Yin, Henghui; Chang, Guangqi

    2017-08-01

    The chimney graft (CG) technique has been proposed as a complete endovascular supra-aortic branch reconstruction for aortic pathologies. Due to the rapid growth of thoracic endovascular aortic repair (TEVAR) in China, we aimed to investigate the current data of the CG technique in this most populous country. Studies of supra-aortic branch reconstruction using the CG technique from Chinese centers were collected and analyzed. A total of 294 patients from Chinese centers who underwent TEVAR with CGs were included. There were 301 CGs performed, with a technical successful rate of 97.7%. The rate of early type I endoleaks was 7.1%, and the patency rate of the CGs was desirable. Balloon-expandable bare CGs were significantly associated with good early outcomes and a low rate of endoleaks. Current data from China revealed positive outcomes using CGs for supra-aortic branch reconstruction. Balloon-expandable bare CGs may be the first choice according to the data available but should be considered with caution.

  8. Technologies developed by CNES balloon team

    Science.gov (United States)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling

  9. Recent Developments in Scientific Research Ballooning

    International Nuclear Information System (INIS)

    Jones, W. Vernon

    2007-01-01

    The National Aeronautics and Space Administration (NASA) Balloon Program is committed to meeting the need for extended duration scientific investigations by providing advanced balloon vehicles and support systems. A sea change in ballooning capability occurred with the inauguration of 8 - 20 day flights around Antarctica in the early 1990's. The attainment of 28-31 day flights and a record-breaking 42-day flight in, respectively, two and three circumnavigations of the continent has greatly increased the expectations of the scientific users. A new super-pressure balloon is currently under development for future flights of 60-100 days at any latitude, which would bring another sea change in scientific research ballooning

  10. Early Cosmic Ray Research with Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Michael, E-mail: michael.walter@desy.de

    2013-06-15

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  11. Early Cosmic Ray Research with Balloons

    Science.gov (United States)

    Walter, Michael

    2013-06-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  12. Early Cosmic Ray Research with Balloons

    International Nuclear Information System (INIS)

    Walter, Michael

    2013-01-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster

  13. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. Comparison of two doses of heparin on outcome in off-pump coronary artery bypass surgery patients: A prospective randomized control study

    Directory of Open Access Journals (Sweden)

    Murali Chakravarthy

    2017-01-01

    Full Text Available Introduction: While off pump coronary artery bypass surgery is practiced with an intention to reduce the morbidity associated with cardiopulmonary bypass, the resultant ′hypercoagulability′ needs to be addressed. Complications such as cavitary thrombus possibly due to the hyper coagulability after off pump coronary artery bypass surgery have been described. Many clinicians use higher doses of heparin - up to 5 mg/kg in order to thwart this fear. Overall, there appears to be no consensus on the dose of heparin in off pump coronary artery bypass surgeries. Aim of the Study: The aim of the study was understand the differences in outcome of such as transfusion requirement, myocardial ischemia, and morbidity when two different doses were used for systemic heparinization. Methods: Elective patients scheduled for off pump coronary artery bypass surgery were included. Ongoing anti platelet medication was not an exclusion criteria, however, anti platelet medications were ceased about a week prior to surgery when possible. Thoracic epidural anesthesia was administered as an adjunct in patients who qualified for it. By computer generated randomization chart, patients were chosen to receive either 2 or 3 mg/kg of intravenous unfractioned heparin to achieve systemic heparinization with activated clotting time targeted at >240 secs. Intraoperative blood loss, postoperative blood loss, myocardial ischemic episodes, requirement of intraaortic balloon counter pulsation and transfusion requirement were analyzed. Results: Sixty two patients participated in the study. There was one conversion to cardiopulmonary bypass. The groups had comparable ACT at baseline (138.8 vs. 146.64 seconds, P = 0.12; 3 mg/kg group had significantly higher values after heparin, as expected. But after reversal with protamine, ACT and need for additional protamine was similar among the groups. Intraoperative (685.56 ± 241.42 ml vs. 675.15 ± 251.86 ml, P = 0.82 and postoperative

  15. Simultaneous rota-stenting and transcatheter aortic valve implantation for patients with heavily calcified coronary stenosis and aortic stenosis

    Directory of Open Access Journals (Sweden)

    Yung-Tsai Lee

    2016-09-01

    Full Text Available Given that coronary artery disease (CAD in octogenarians undergoing transcatheter aortic valve implantation (TAVI often presents with more complex lesions and extensive calcification, rotational atherectomy (RA may be needed in some cases before stenting. However, data regarding the feasibility and safety of simultaneous RA during TAVI using the Medtronic CoreValve (MCV; Medtronic, Minneapolis, MN, USA system are lacking. Three out of 107 (2.8% patients (2 females, average age 85.6 years, mean aortic valve area 0.5 cm2, mean left ventricular ejection fraction 39%, mean Logistic EuroScore 70%, with complex, heavily calcified coronary stenosis, and severe valvular aortic stenosis (AS were treated with TAVI and RA due to high surgical risk. After balloon valvuloplasty, all coronary lesions were successfully treated with RA and stenting, immediately followed by transfemoral TAVI with a self-expandable MCV. Our data suggested that in the very elderly patients with severe and heavily calcified CAD and AS who were turned down for cardiac surgery, RA and stenting followed by TAVI may be performed successfully in a combined, single-stage procedure.

  16. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  17. Esophageal achalasia : results of balloon dilation

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-08-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia.

  18. Esophageal achalasia : results of balloon dilation

    International Nuclear Information System (INIS)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young

    1996-01-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia

  19. Heat Transfer Model for Hot Air Balloons

    Science.gov (United States)

    Llado-Gambin, Adriana

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the modeling based on typical thermal input from a balloon propane burner. The burner duty cycle to keep a constant altitude can vary from 10% to 28% depending on the atmospheric conditions, and the ambient temperature is the parameter that most affects the total thermal input needed. The simulation and analysis also predict that the gas temperature inside the balloon decreases at a rate of -0.25 K/s when there is no burner activity, and it increases at a rate of +1 K/s when the balloon pilot operates the burner. The results were compared to actual flight data and they show very good agreement indicating that the major physical processes responsible for balloon performance aloft are accurately captured in the simulation.

  20. Balloon Occlusion of the Contralateral Iliac Artery to Assist Recanalization of the Ipsilateral Iliac Artery in Total Aortoiliac Occlusion: A Technical Note

    Directory of Open Access Journals (Sweden)

    Abdel Aziz A. Jaffan

    2013-01-01

    Full Text Available Endovascular recanalization of chronic total aortoiliac occlusion is technically challenging. Inability to reenter the true aortic lumen, following retrograde iliac recanalization, is one of the most common causes of failure. We describe a case of a total aortoiliac occlusion where balloon occlusion of the right common iliac artery, following its recanalization from a brachial approach, was used to facilitate antegrade recanalization of the occluded contralateral left common iliac artery.

  1. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  2. Solar Pump

    Science.gov (United States)

    Pique, Charles

    1987-01-01

    Proposed pump moves liquid by action of bubbles formed by heat of sun. Tube of liquid having boiling point of 100 to 200 degrees F placed at focal axis of cylindrical reflector. Concentrated sunlight boils liquid at focus, and bubbles of vapor rise in tube, carrying liquid along with them. Pressure difference in hot tube sufficient to produce flow in large loop. Used with conventional flat solar heating panel in completely solar-powered heat-storage system.

  3. Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients.

    Science.gov (United States)

    Haverich, Axel; Wahlers, Thorsten C; Borger, Michael A; Shrestha, Malakh; Kocher, Alfred A; Walther, Thomas; Roth, Matthias; Misfeld, Martin; Mohr, Friedrich W; Kempfert, Joerg; Dohmen, Pascal M; Schmitz, Christoph; Rahmanian, Parwis; Wiedemann, Dominik; Duhay, Francis G; Laufer, Günther

    2014-12-01

    Superior aortic valve hemodynamic performance can accelerate left ventricular mass regression and enhance survival and functional status after surgical aortic valve replacement. This can be achieved by rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame, which functionally widens and reshapes the left ventricular outflow tract, to ensure a larger effective orifice area compared with conventional surgical valves. We report the intermediate-term follow-up data from a large series of patients enrolled in the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial. In a prospective, multicenter (6 European hospitals), single-arm study, 287 patients with aortic stenosis underwent rapid deployment aortic valve replacement using a stented trileaflet bovine pericardial bioprosthesis. Core laboratory echocardiography was performed at baseline, discharge, and 3 months, 1 year, and 3 years after rapid deployment aortic valve replacement. The mean patient age was 75.7 ± 6.7 years (range, 45-93; 49.1% women). The mean aortic valve gradient significantly decreased from discharge to 3 years of follow-up. The mean effective orifice area remained stable from discharge to 3 years. At 1 year, the left ventricular mass index had decreased by 14% (P replacement using a subannular balloon-expandable stent frame demonstrated excellent hemodynamic performance and significant left ventricular mass regression. With continued follow-up, future studies will establish whether these favorable structural changes correlate with improvement in long-term survival and functional status. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  5. Heat Transfer Model for Hot Air Balloons

    OpenAIRE

    Lladó Gambín, Adriana

    2016-01-01

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the mod...

  6. Aortic obstruction: anatomy and echocardiography

    Directory of Open Access Journals (Sweden)

    Keirns Candace

    2006-09-01

    Full Text Available Abstract Echocardiography is a valuable non-invasive technique for identifying the site and type of aortic obstruction. Knowledge of the morphological details of each type of obstruction is the basis for correct interpretation of the diagnostic images and clinical decisions. This study was undertaken to correlate the echocardiographic images with anatomic specimens of equivalent valvular and supravalvular aortic obstruction. Specimens were part of the collection of the Department of Embryology. Fifty six patients were studied, and forty specimens with aortic obstruction were analyzed. Echocardiographic characteristics: Thirty one (55.3% patients were women and twenty five (44.7% men. Valvular aortic obstruction was found in Thirty six patients (64.3 % and supravalvular aortic obstruction in twenty (35.7%. Anatomic characteristics: Of the forty specimens examined, twenty one (52.5% had valvular aortic obstruction and nineteen (47.5% supravalvular aortic obstruction. The anatomoechocardiographic correlation clearly showed that the anatomic findings of the specimen hearts and aortas corresponded to echocardiographic images of valvular and supravalvular aortic obstruction and provided solid corroboration of echocardiographic diagnoses.

  7. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch

    DEFF Research Database (Denmark)

    Millan-Iturbe, Oscar; Sawaya, Fadi J.; Bieliauskas, Gintautas

    2017-01-01

    AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a “gothic aortic arch”; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled...

  8. The adventitia layer modulates the arterial wall elastic response to intra-aortic counterpulsation: in vivo studies.

    Science.gov (United States)

    Cabrera-Fischer, Edmundo I; Bia, Daniel; Zócalo, Yanina; Wray, Sandra; Armentano, Ricardo

    2013-12-01

    There is a relationship between the intra-aortic balloon pumping (IABP) benefits and the dynamic behavior of muscular arteries, which is associated with induced changes on the vessel walls through an endothelial-dependent mechanism. The arterial wall elastic behavior is influenced by adventitial function; however, no studies were performed in order to elucidate if this layer plays a role in the changes determined by IABP. Our aim was to quantify acute IABP effects on the mechanical properties of muscular arteries in induced acute heart failure (AHF), before and after adventitia removal. Pressure and diameter were recorded in the iliac arteries (IA) of sheep (n = 7), before and during 1:2 IABP: (i) in control state (CS) with intact IA, (ii) in CS after IA adventitia removal, and (iii) in de-adventitialized IA after AHF. Conduit function, compliance and arterial distensibility were calculated in each state. During CS, IABP resulted in intact IA dilatation and in an increase in conduit function, compliance and distensibility; adventitial removal determined an increase of arterial stiffness with respect to the CS, which decreased when IABP was used; the increase in arterial stiffness observed after adventitia removal was also detected in AHF state; IABP improves conduit function and arterial stiffness in de-adventitialized arteries, both before and during AHF. However, the improvement in these properties was lower than in intact arteries. Before and after AHF induction, the improvements of conduit function and arterial distensibility determined by IABP in intact IA were significantly reduced after adventitia removal. Adventitial layer integrity would be necessary to maximize IABP-related beneficial effects on arterial system properties. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  9. Satisfactory short-term outcomes of the STABILISE technique for type B aortic dissection.

    Science.gov (United States)

    Melissano, Germano; Bertoglio, Luca; Rinaldi, Enrico; Mascia, Daniele; Kahlberg, Andrea; Loschi, Diletta; De Luca, Monica; Monaco, Fabrizio; Chiesa, Roberto

    2018-03-29

    The aim of this study was to evaluate the perioperative and short-term results in a cohort of patients treated during the last year at our institution with the stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) technique for acute complicated aortic dissection. Between June 2016 and June 2017, 10 patients (all male; mean age, 62.6 ± 7.4 years) received treatment for acute complicated aortic dissection with the STABILISE technique. After a standard provisional extension to induce complete attachment procedure using the commercially available endovascular dissection system (Cook Medical, Bloomington, Ind), the distal stent graft area and the bare stent area were ballooned to completely exclude the thoracic false lumen (FL) and to obtain a single-channeled abdominal aorta. Computed tomography was routinely performed within the first postoperative week before discharge and then at 3 months, at 6 months, and yearly thereafter. The technical and clinical success rates were analyzed. The 30-day technical and clinical success rates were 100%, with complete thrombosis of the thoracic FL and no type I endoleak. Malperfusion was resolved in all cases. No aortic ruptures were recorded, and no open conversion was required. One case of delayed spinal cord ischemia fully resolved within the discharge period. Predischarge computed tomography showed complete thrombosis of the thoracic FL in all cases. In two cases, some degree of patency of the abdominal FL was observed. At short-term follow-up, the overall aortic diameters remained stable with no further dilation. The STABILISE technique was safe and feasible in this cohort of patients, with complete thrombosis of the thoracic FL and creation of a single-channeled aorta in most cases. Further studies are needed to ascertain the long-term behavior of the treated aorta. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  11. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome.

    Science.gov (United States)

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-12-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitation and chronic descending aortic dissection immediately after Cesarean section. Regular follow-up will be needed to monitor the descending aortic dissection.

  12. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  13. More than just a urinary catheter — Haemorrhage control by using a Foley catheter in a penetrating aortic root injury

    Directory of Open Access Journals (Sweden)

    Adel Elmoghrabi

    2016-08-01

    Full Text Available The prevalence of great vessel injuries in thoracic trauma is reported at 0.3–10%, predominantly due to a penetrating mechanism. Thoracic aortic injuries, more specifically those within proximity of the aortic root are challenging to manage and unceasing bleeding hampers adequate visualisation for performing repair. We report a case of a 31-year-old male that presented to the emergency department 1 h after sustaining a stab wound injury within proximity of the left upper sternal border. Vital signs were stable on presentation. Physical examination revealed a 1.5 cm laceration in the 3rd intercostal space. Chest X-ray revealed a small left pneumothorax, FAST scan was negative, and CT of the chest revealed left sided haemopneumothorax and haemopericardium. The patient was emergently transferred to the operating room where median thoracotomy was performed. A significant amount of bleeding was observed originating from a 1 cm laceration of the aortic root. Bleeding was controlled using a Foley catheter after unsuccessful attempts of digital compression, and the laceration was repaired using pledgeted sutures. Postoperative echocardiography and CT scan of the chest revealed normal cardiac functions with resolution of haemopericardium and haemopneumothorax, and the patient was discharged in a stable condition. High index of suspicion should be maintained for injury to the great vessels in patients with penetrating chest injuries, despite apparent haemodynamic stability. In this case, balloon tamponade using a Foley catheter served as a quick and simple technique that resulted in an almost bloodless field, facilitating adequate visualisation for definitive repair. Although the use of this technique has been previously described, this report serves as a reminder that a Foley catheter can be successfully used for balloon catheter tamponade in injuries to the aortic root. Keywords: Aortic root, Injury, Foley's catheter, Balloon catheter, Aorta

  14. Solid State Inflation Balloon Active Deorbiter

    Data.gov (United States)

    National Aeronautics and Space Administration — The Solid State Inflation Balloon (SSIB) is a simple, reliable, low-cost, non-propulsive system for deliberate deorbit and control of downrange point-of-impact that...

  15. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  16. Gigantic balloon type artificial lightning generator

    Energy Technology Data Exchange (ETDEWEB)

    Horii; kenji

    1988-09-05

    This paper outlines a hot-air balloon type Van de Graaf 50-MV generator which can generate a 50,000,000 V, 0.2 to 0.3 coulomb artificial lightning comparable to natural lightning discharge and reports the results of investigation on discharging experiments conducted using this apparatus. The subjects covered are as follows: (1) Outline of the hot-air balloon type Van de Graaf 50-MV generator, (2) electric characteristics of the Van de Graaf 50-MV generator, (3) charge transfer with film and balloon charging, (4) the load of the balloon and buoyancy calculation, (5) leakage of charges, (6) study of charging experiments, and (7) evaluation of the apparatus and its method and problems to be solved. (4 figs, 4 tabs, 4 refs)

  17. Abdominal Aortic Emergencies.

    Science.gov (United States)

    Lech, Christie; Swaminathan, Anand

    2017-11-01

    This article discusses abdominal aortic emergencies. There is a common thread of risk factors and causes of these diseases, including age, male gender, hypertension, dyslipidemia, and connective tissue disorders. The most common presenting symptom of these disorders is pain, usually in the chest, flank, abdomen, or back. Computed tomography scan is the gold standard for diagnosis of pathologic conditions of the aorta in the hemodynamically stable patient. Treatment consists of a combination of blood pressure and heart rate control and, in many cases, emergent surgical intervention. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. The UK sounding rocket and balloon programme

    International Nuclear Information System (INIS)

    Delury, J.T.

    1980-01-01

    The UK civil science balloon and rocket programmes for 1979/80/81 are summarised and the areas of scientific interest for the period 1981/85 mentioned. In the main the facilities available are 10 in number balloons up to 40 m cu ft launched from USA or Australia and up to 10 in number 7 1/2'' diameter Petrel rockets. This paper outlines the 1979 and 1980 programmes and explains the longer term plans covering the next 5 years. (Auth.)

  19. Test ventilation with smoke, bubbles, and balloons

    International Nuclear Information System (INIS)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs

  20. Trace gas measurements from tethered balloon platforms

    Science.gov (United States)

    Bandy, Alan R.; Bandy, Terese L.; Youngbluth, Otto; Owens, Thomas L.

    1987-01-01

    Instrumentation and chemical sampling and analysis procedures are described for making measurements of atmospheric carbon disulfide in the concentration range 1-1000 pptv from tethered balloon platforms. Results of a study on the CS2 composition of air downward of a saltwater marsh are reported. A method for obtaining the necessary data for solving the budget equations for surface fluxes, chemical formation rates and chemical destruction rates using data acquired from tethered balloon platforms is presented.

  1. TMBM: Tethered Micro-Balloons on Mars

    Science.gov (United States)

    Sims, M. H.; Greeley, R.; Cutts, J. A.; Yavrouian, A. H.; Murbach, M.

    2000-01-01

    The use of balloons/aerobots on Mars has been under consideration for many years. Concepts include deployment during entry into the atmosphere from a carrier spacecraft, deployment from a lander, use of super-pressurized systems for long duration flights, 'hot-air' systems, etc. Principal advantages include the ability to obtain high-resolution data of the surface because balloons provide a low-altitude platform which moves relatively slowly. Work conducted within the last few years has removed many of the technical difficulties encountered in deployment and operation of balloons/aerobots on Mars. The concept proposed here (a tethered balloon released from a lander) uses a relatively simple approach which would enable aspects of Martian balloons to be tested while providing useful and potentially unique science results. Tethered Micro-Balloons on Mars (TMBM) would be carried to Mars on board a future lander as a stand-alone experiment having a total mass of one to two kilograms. It would consist of a helium balloon of up to 50 cubic meters that is inflated after landing and initially tethered to the lander. Its primary instrumentation would be a camera that would be carried to an altitude of up to tens of meters above the surface. Imaging data would be transmitted to the lander for inclusion in the mission data stream. The tether would be released in stages allowing different resolutions and coverage. In addition during this staged release a lander camera system may observe the motion of the balloon at various heights above he lander. Under some scenarios upon completion of the primary phase of TMBM operations, the tether would be cut, allowing TMBM to drift away from the landing site, during which images would be taken along the ground.

  2. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome

    OpenAIRE

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-01-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitat...

  3. Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation

    Directory of Open Access Journals (Sweden)

    Karel Van Praet

    2015-07-01

    Full Text Available Aortic regurgitation and dilatation of the aortic root and ascending aorta are severe complications of acromegaly. The current trend for management of an aortic root aneurysm is valve-sparing root replacement as well as restoring the diameter of the aortic sinotubular junction (STJ and annulus. Our case report supports the recommendation that in patients with acromegaly, severe aortic root involvement may indicate the need for surgery.

  4. CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI)-predictive value and optimal thresholds for major anatomic parameters.

    Science.gov (United States)

    Schwarz, Florian; Lange, Philipp; Zinsser, Dominik; Greif, Martin; Boekstegers, Peter; Schmitz, Christoph; Reiser, Maximilian F; Kupatt, Christian; Becker, Hans C

    2014-01-01

    To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI) and to calculate optimal cutoff values for the selection of various prosthesis sizes. The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67). In the remaining 351 patients, the CoreValve (Medtronic) and the Edwards Sapien XT valve (Edwards Lifesciences) were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values. Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p'sprosthesis size for both manufacturers (multi-class AUC's: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89). Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases. CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.

  5. CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI-predictive value and optimal thresholds for major anatomic parameters.

    Directory of Open Access Journals (Sweden)

    Florian Schwarz

    Full Text Available BACKGROUND/OBJECTIVES: To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI and to calculate optimal cutoff values for the selection of various prosthesis sizes. METHODS: The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67. In the remaining 351 patients, the CoreValve (Medtronic and the Edwards Sapien XT valve (Edwards Lifesciences were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values. RESULTS: Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p's<0.05. Furthermore, mean diameter, annulus area and circumference had equally high predictive value for prosthesis size for both manufacturers (multi-class AUC's: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89. Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases. CONCLUSION: CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.

  6. Unusual Case of Overt Aortic Dissection Mimicking Aortic Intramural Hematoma

    Directory of Open Access Journals (Sweden)

    Kushtrim Disha

    2016-04-01

    Full Text Available We report an interesting case in which overt aortic dissection mimicked two episodes of aortic intramural hematoma (IMH (Stanford A, DeBakey I. This took place over the course of four days and had a major influence on the surgical treatment strategy. The first episode of IMH regressed completely within 15 hours after it was clinically diagnosed and verified using imaging techniques. The recurrence of IMH was detected three days thereafter, resulting in an urgent surgical intervention. Overt aortic dissection with evidence of an intimal tear was diagnosed intraoperatively.

  7. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  8. Aortic root replacement after previous surgical intervention on the aortic valve, aortic root, or ascending aorta.

    Science.gov (United States)

    Kirsch, E W Matthias; Radu, N Costin; Mekontso-Dessap, Armand; Hillion, Marie-Line; Loisance, Daniel

    2006-03-01

    Aortic root replacement after a previous operation on the aortic valve, aortic root, or ascending aorta remains a major challenge. Records of 56 consecutive patients (44 men; mean age, 56.4 +/- 13.6 years) undergoing reoperative aortic root replacement between June 1994 and June 2005 were reviewed retrospectively. Reoperation was performed 9.4 +/- 6.7 years after the last cardiac operation. Indications for reoperation were true aneurysm (n = 14 [25%]), false aneurysm (n = 10 [18%]), dissection or redissection (n = 9 [16%]), structural or nonstructural valve dysfunction (n = 10 [18%]), prosthetic valve-graft infection (n = 12 [21%]), and miscellaneous (n = 1 [2%]). Procedures performed were aortic root replacement (n = 47 [84%]), aortic root replacement plus mitral valve procedure (n = 5 [9%]), and aortic root replacement plus arch replacement (n = 4 [7%]). In 14 (25%) patients coronary artery bypass grafting had to be performed unexpectedly during the same procedure or immediately after the procedure to re-establish coronary perfusion. Hospital mortality reached 17.9% (n = 10). Multivariate logistic regression analysis revealed the need for unplanned perioperative coronary artery bypass grafting as the sole independent risk factor for hospital death (P = .005). Actuarial survival was 83.8% +/- 4.9% at 1 month, 73.0% +/- 6.3% at 1 year, and 65.7% +/- 9.0% at 5 years after the operation. One patient had recurrence of endocarditis 6.7 months after the operation and required repeated homograft aortic root replacement. Reoperative aortic root replacement remains associated with a high postoperative mortality. The need to perform unplanned coronary artery bypass grafting during reoperative aortic root replacement is a major risk factor for hospital death. The optimal technique for coronary reconstruction in this setting remains to be debated.

  9. Reinforced aortic root reconstruction for acute type A aortic dissection involving the aortic root

    Directory of Open Access Journals (Sweden)

    Han Qing-qi

    2013-06-01

    Full Text Available OBJECTIVE: There are debates regarding the optimal approach for AAAD involving the aortic root. We described a modified reinforced aortic root reconstruction approach for treating AAAD involving the aortic root. METHODS: A total of 161 patients with AAAD involving the aortic root were treated by our modified reinforced aortic root reconstruction approach from January 1998 to December 2008. Key features of our modified approach were placement of an autologous pericardial patch in the false lumen, lining of the sinotubular junction lumen with a polyester vascular ring, and wrapping of the vessel with Teflon strips. Outcome measures included post-operative mortality, survival, complications, and level of aortic regurgitation. RESULTS: A total of 161 patients were included in the study (mean age: 43.3 1 15.5 years. The mean duration of follow-up was 5.1 1 2.96 years (2-12 years. A total of 10 (6.2% and 11 (6.8% patients died during hospitalization and during follow-up, respectively. Thirty-one (19.3% patients experienced postoperative complications. The 1-, 3-, 5-, and 10-year survival rates were 99.3%, 98%, 93.8%, and 75.5%, respectively. There were no instances of recurrent aortic dissection, aortic aneurysm, or pseudoaneurysm during the entire study period. The severity of aortic regurgitation dramatically decreased immediately after surgery (from 28.6% to 0% grade 3-4 and thereafter slightly increased (from 0% to 7.2% at 5 years and 9.1% at 10 years. CONCLUSION: This modified reinforced aortic root reconstruction was feasible, safe and durable/effective, as indicated by its low mortality, low postoperative complications and high survival rate.

  10. Current indications for stentless aortic bioprostheses.

    Science.gov (United States)

    Hegazy, Yasser Y; Rayan, Amr; Bauer, Stefan; Keshk, Noha; Bauer, Kerstin; Ennker, Ina; Ennker, Jürgen

    2018-01-01

    The best aortic prostheses have been debated for decades. The introduction of stentless aortic bioprostheses was aimed at improving hemodynamics and potentially the durability of aortic bioprostheses. Despite the good short- and long-term outcomes after implantation of stentless aortic bioprostheses, their use remains limited owing to the technically demanding implantation techniques. Nevertheless, stentless aortic bioprostheses might be of special benefit in certain indications, where they could be a valuable addition to the surgical armamentarium.

  11. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  12. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  13. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge; Grønbæk, Morten

    2013-01-01

    BACKGROUND: We determined the predictive power of tobacco smoking on aortic aneurysm as opposed to other risk factors in the general population. METHODS: We recorded tobacco smoking and other risk factors at baseline, and assessed hospitalization and death from aortic aneurysm in 15,072 individuals...... aneurysm in males and females consuming above 20g tobacco daily was 3.5% and 1.3%, among those >60years with plasma cholesterol >5mmol/L and a systolic blood pressure >140mmHg. CONCLUSIONS: Tobacco smoking is the most important predictor of future aortic aneurysm outcomes in the general population...

  14. Internal pump

    International Nuclear Information System (INIS)

    Kushima, Jun; Hayashi, Youjiro; Ueda, Masayuki.

    1997-01-01

    The present invention relates to an internal pump. A water hole allowing communication between internal and external circumferences of a stretch tube is provided at the portion of the stretch tube corresponding to a position where an end face of a nozzle portion of a motor case and an end face of a diffuser are joined with each other so that hot filtered water inside a pressure container which has entered from where the end face of the nozzle portion of the motor case and the end face of the diffuser are joined with each other is combined with the purged water so that it can be sent back to the pressure container again. (author) figs

  15. Reoperative Aortic Root Replacement in Patients with Previous Aortic Root or Aortic Valve Procedures

    Directory of Open Access Journals (Sweden)

    Byung Kwon Chong

    2016-08-01

    Full Text Available Background: Generalization of standardized surgical techniques to treat aortic valve (AV and aortic root diseases has benefited large numbers of patients. As a consequence of the proliferation of patients receiving aortic root surgeries, surgeons are more frequently challenged by reoperative aortic root procedures. The aim of this study was to evaluate the outcomes of redo-aortic root replacement (ARR. Methods: We retrospectively reviewed 66 patients (36 male; mean age, 44.5±9.5 years who underwent redo-ARR following AV or aortic root procedures between April 1995 and June 2015. Results: Emergency surgeries comprised 43.9% (n=29. Indications for the redo-ARR were aneurysm (n=12, pseudoaneurysm (n=1, or dissection (n=6 of the residual native aortic sinus in 19 patients (28.8%, native AV dysfunction in 8 patients (12.1%, structural dysfunction of an implanted bioprosthetic AV in 19 patients (28.8%, and infection of previously replaced AV or proximal aortic grafts in 30 patients (45.5%. There were 3 early deaths (4.5%. During follow- up (median, 54.65 months; quartile 1–3, 17.93 to 95.71 months, there were 14 late deaths (21.2%, and 9 valve-related complications including reoperation of the aortic root in 1 patient, infective endocarditis in 3 patients, and hemorrhagic events in 5 patients. Overall survival and event-free survival rates at 5 years were 81.5%±5.1% and 76.4%±5.4%, respectively. Conclusion: Despite technical challenges and a high rate of emergency conditions in patients requiring redo-ARR, early and late outcomes were acceptable in these patients.

  16. Breastfeeding FAQs: Pumping

    Science.gov (United States)

    ... of pump is best? You can buy or rent a breast pump from lactation consultants, hospitals, retail ... place to do it. Many companies offer their employees pumping and nursing areas. If yours doesn't, ...

  17. The bicuspid aortic valve and its relation to aortic dilation

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2010-01-01

    Full Text Available BACKGROUND: A bicuspid aortic valve (BAV is a common congenital heart disease, which affects 1-2% of the population. However, the relationship between BAVs and aortic dilation has not been sufficiently elucidated. METHODS: A total of 241 BAV patients who were referred to this hospital for cardiac surgey over a 4.75-year period were included in this study. In addition to the clinical characteristics of the included patients, the morphological features of the aortic valve and aorta, the length of the left main coronary artery, and the laboratory findings (the coagulation and hematological parameters as well as the total cholesterol concentration were determined and compared with those of the tricuspid aortic valve (TAV patients. RESULTS: The BAV patients were younger than the TAV patients for a valve surgery in the last 3 months of the study period. The BAV patients were predominantly male. Most of the BAVs that were surgically treated were stenotic, regurgitant, or combined, and only 19 (7.88% were normally functioning valves. According to echocardiography or operative records, 148 (78.31% were type A, 31 (16.40% were type B, and 10 (5.29% were type C. The left main coronary artery was much shorter in the BAV patients than it was in the TAV patients. There was no significant difference between BAV and TAV patients in the total cholesterol concentrations; whereas differences were noted between patients receiving lipid-lowering therapy and those not receiving lipid-lowering therapy. The dimensions of the aortic root, sinotubular junction, and ascending aorta were beyond normal limits, while they were significantly smaller in the BAV patients than in the TAV patients. They were also much smaller in patients receiving statin therapy than those not receiving statin therapy in both groups. Moreover, the aortic dilation in the BAV group was found to be significantly associated with patient age. CONCLUSIONS: The BAV patients developed aortic wall and

  18. Abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lindholt, Jes S.

    2010-01-01

    Although the number of elective operations for abdominal aortic aneurysms (AAA) is increasing, the sex- and age-standardised mortality rate of AAAs continues to rise, especially among men aged 65 years or more. The lethality of ruptured AAA continues to be 80-95%, compared with 5-7% by elective...... surgery of symptomfree AAA. In order to fulfil all WHO, European, and Danish criteria for screening, a randomised hospitalbased screening trial of 12,639 65-73 year old men in Viborg County (Denmark) was initiated in 1994. It seemed that US screening is a valid, suitable and acceptable method of screening...... patients without previous hospital discharge diagnoses due to cardiovascular disease than among similar men without AAA. The absolute risk difference after 5 years was 16%. So, they will benefit from general cardiovascular preventive action as smoking cessation, statins and low-dose aspirin, which could...

  19. Abdominal aortic aneurysm surgery

    DEFF Research Database (Denmark)

    Gefke, K; Schroeder, T V; Thisted, B

    1994-01-01

    The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 553...... patients, 51 (9%) of whom died within the first 48 hours. Of the 502 patients who survived for more than 48 hours, 109 required ICU therapy for more than 48 hours, whereas 393 patients were in the ICU for less than 48 hours. The incidence of preoperative risk factors was similar for the two groups...... combined failed to permit identification of patients in whom the perioperative survival rate was 0%. Even 20% of patients with multiorgan failure survived for 6 months. Of those patients who needed ICU therapy for more than 48 hours, 41 (38%) were alive at the end of 1988. In response to a questionnaire...

  20. Evaluation of the aortic anulus

    International Nuclear Information System (INIS)

    Link, K.M.; Margosian, P.

    1991-01-01

    This paper evaluates the efficacy of echocardiography and MR imaging for measuring the aortic anulus in patients who are candidates for aortic valve replacement. The MR imaging study was performed on a 1.5-T system, and the results were compared with echocardiography results obtained with use of a Toshiba system with a 2.5-mHz transducer. The aortic valve anulus was evaluated in the coronal, long-axis, and short-axis views with the MR imaging technique and in the right parasternal suprasternal, and apical projections with the echocardiographic technique. Twenty-four patients studied with MR imaging and echocardiography went on to have aortic valve replacement. When compared with surgical results, MR imaging had an r value of .95 while echocardiography had an r value of .70

  1. Imaging techniques in transcatheter aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Quaife RA

    2013-11-01

    Full Text Available Robert A Quaife, Jennifer Dorosz, John C Messenger, Ernesto E Salcedo Division of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Calcific aortic stenosis is now understood as a complex valvular degenerative process sharing many risk factors with atherosclerosis. Once patients develop symptomatic calcific aortic stenosis, the only effective treatment is aortic valve replacement. In the past decade, transcatheter aortic valve replacement (TAVR has been developed as an alternative to surgery to treat severe calcific aortic stenosis. Cardiac imaging plays a pivotal role in the contemporary management of patients with calcific aortic stenosis, and particularly in patients being considered for TAVR, who demand detailed imaging of the aortic valve apparatus. In this review, we highlight the role of cardiac imaging for patient selection, procedural guidance, and evaluation of results of TAVR. Keywords: aortic stenosis, cardiovascular imaging, transcutaneous aortic valve replacement

  2. Balloon cell nevus of the iris.

    Science.gov (United States)

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  3. Alkaptonuria-associated aortic stenosis.

    Science.gov (United States)

    Lok, Zoe S Y; Goldstein, Jacob; Smith, Julian A

    2013-07-01

    Alkaptonuria is an autosomal recessive disorder of tyrosine metabolism, which results in accumulation of unmetabolized homogentisic acid and its oxidized product in various tissues, including the heart. Cardiovascular involvement is a rare but serious complication of the disease. We present two patients who have undergone successful aortic valve replacement for alkaptonuria-associated aortic stenosis along with a review of the literature. © 2013 Wiley Periodicals, Inc.

  4. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  5. Liquid metal pump

    Science.gov (United States)

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  6. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair

  7. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  8. Scientific ballooning. Proceedings of the symposium on the scientific use of balloons and related technical problems, Innsbruck, Austria, May 29-June 10, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Riedler, W

    1979-01-01

    The book includes works on operational and technical aspects of balloon launching I and II, cooperative balloon campaigns, and new developments in scientific use of balloons. The specific topics discussed are coordinated balloon and rocket measurements of stratospheric wind shears and turbulence, ballooning in Japan and India, magnetospheric processes investigated with data taken from balloon flights, and remote sensing of middle atmosphere winds from balloon platforms.

  9. Suprarenal fixation resulting in intestinal malperfusion after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Siani, Andrea; Accrocca, Federico; De Vivo, Gennaro; Marcucci, Giustino

    2016-05-01

    Superior mesenteric artery (SMA) and coeliac axis (CA) occlusion after endovascular abdominal aneurysm aortic repair (EVAR-AAA), using endograft with suprarenal fixation, are uncommon. However, we are reporting a case of visceral malperfusion, which occurred 7 days after successful EVAR with suprarenal fixation for symptomatic AAA. Endograft metal stent barbs caused severe stenosis of SMA and CA. A successful recovery of SMA was carried out by means of a balloon-expandable stent released through bare metal stent barbs. We believe that an unfavourable anatomy of a proximal aortic neck and visceral aorta may have caused a wrong stent strut deployment with the coverage of CA and SMA. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  11. [Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].

    Science.gov (United States)

    Santiago, Justo; Acuña, Manuel; Arispe, Elizabeth; Camargo, Ronaldo; Neves, Juliana; Arnoni, Daniel; Fontes, Valmir F; Pedra, Carlos A

    2007-03-01

    The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the defects using Amplatzer devices. In two patients, although angiography demonstrated the presence of type-A patent ductus arteriosus, it was not possible to determine the minimum diameter accurately and it was necessary to measure it using a sizing balloon. An Amplatzer duct occluder was used in two patients and an Amplatzer muscular ventricular septal defect occluder, in the other. In all patients, full closure was confirmed in the catheterization laboratory and the patients were discharged on the same day with no complications. Percutaneous closure of a right patent ductus arteriosus associated with a right aortic arch is feasible, safe and effective.

  12. Results of aortic root reimplantation in patients with ascending aortic aneurysm and concomitant aortic insufficiency

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-01-01

    Full Text Available Objective. The research was designed to evaluate the results of valve-sparing operations: aortic root reimplantation versus aortic valve reimplantation when repairing an ascending aortic aneurysm with concomitant aortic insufficiency.Methods. Within a blind prospective randomized study conducted over a period from 2011 to 2015, 64 patients underwent aortic valve-sparing surgery. The inclusion criteria were the presence of an aortic aneurysm of the ascending aorta exceeding 4.5 cm and concomitant aortic insufficiency. All patients were divided into two groups: FS-group, aortic root reimplantation (modified Florida Sleeve technique (n = 32 and D-group, aortic valve reimplantation (David procedure (n = 32. The average age of patients was 57±13 (23–73 years in the FS-group and 55±11 (15–72 years in the D-group (p = 0.54. Both groups had 78% of males (p>0.99. A Marfan syndrome was identified in 6% and 9% in the FS-group and D-group respectively (p>0.99. Mean diameter of the sinuses of Valsalva was 51±7 mm and 56±10 mm (p = 0.09, aortic insufficiency 2.6±0.7 and 2.8±0.8 (p = 0.15 in the FS-group and D-group respectively. In the FS-group and D-group LVEDD amounted to 5.5±0.7 mm and 5.9±1.0 mm (p = 0.09 respectively. All patients took echocardiography in the preoperative, postoperative and follow-up periods.Results. In the long-term period, the degree of aortic regurgitation was 1.2±0.1 in the FS-group and 1.3±0.6 in the D-group (p = 0.72. LVEDD was 123±23 mm in the FS-group and 139.6±80 mm in the D-group at follow-up (p = 0.77. There were no statistically significant differences in the analysis of complications. Overall 30-day in-hospital mortality was 7.8%. There were 2 (6.3% deaths in the FS-group and 3 (9.4% in the D-group (p = 0.5.Late mortality was 6.3% in the FS-group and 3.1% in the D-group (p>0.99. Cumulative survival at 4 years was 84.3% and 84.8% in the FS-group and the D-group respectively (p = 0.94. Cumulative freedom from

  13. Spectrum of ballooning instabilities in a stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, W A [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP); Singleton, D B [Australian National Univ., ANU Supercomputing Facility, Canberra (Australia); Dewar, R L [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1995-08-01

    The recent revival of interest in the application of the `ballooning formalism` to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs.

  14. Spectrum of ballooning instabilities in a stellarator

    International Nuclear Information System (INIS)

    Cooper, W.A.; Singleton, D.B.; Dewar, R.L.

    1995-08-01

    The recent revival of interest in the application of the 'ballooning formalism' to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs

  15. Analysis of current diffusive ballooning mode

    International Nuclear Information System (INIS)

    Yagi, M.; Azumi, M.; Itoh, K.; Itoh, S.; Fukuyama, A.

    1993-04-01

    The current diffusive ballooning mode is analysed in the tokamak plasma. This mode is destabilized by the current diffusivity (i.e., the electron viscosity) and stabilized by the thermal conductivity and ion viscosity. By use of the ballooning transformation, the eigenmode equation is solved. Analytic solution is obtained by the strong ballooning limit. Numerical calculation is also performed to confirm the analytic theory. The growth rate of the mode and the mode structure are analysed. The stability boundary is derived in terms of the current diffusivity, thermal conductivity, ion viscosity and the pressure gradient for the given shear parameter. This result is applied to express the thermal conductivity in terms of the pressure gradient, magnetic configurational parameters (such as the safety factor, shear and aspect ratio) and the Prandtl numbers. (author)

  16. Balloon dilatation of the prostatic urethra

    International Nuclear Information System (INIS)

    Lee, Yeon Soo; Shim, Hyung Jin; Cha, Kyung Soo; Hong, Ju Hee; Lim, Myung Ah; Kim, Cheol Soo

    1991-01-01

    We analyzed the result of transurethral balloon dilatation in 11 patients with benign prostatic hypertrophy. The procedures were performed under intravenous sedation and local anesthesia with double lumen balloon catheter at 4 atmosphere for 10 minutes. After dilatation, the prostatism symptom scores improved in 10 out of 11 patients and the mean diameter of the prostatic urethra significantly increased form 4.3 mm to 10.2 mm (ρ < 0.005). The procedures were successful not only in lateral lobe hypertrophy but also in median lobe hypertrophy of the prostate. Postdilatation MRI of 1 patient showed an intact prostatic capsule and no periprostatic hematoma. Complications did not develop except in 1 patient with mild hematuria and incontinence. These preliminary results suggest that transurethral balloon dilatation can be an effective and safe treatment modality for benign prostatic hypertrophy

  17. Unconventional ballooning structures for toroidal drift waves

    International Nuclear Information System (INIS)

    Xie, Hua-sheng; Xiao, Yong

    2015-01-01

    With strong gradients in the pedestal of high confinement mode (H-mode) fusion plasmas, gyrokinetic simulations are carried out for the trapped electron and ion temperature gradient modes. A broad class of unconventional mode structures is found to localize at arbitrary poloidal positions or with multiple peaks. It is found that these unconventional ballooning structures are associated with different eigen states for the most unstable mode. At weak gradient (low confinement mode or L-mode), the most unstable mode is usually in the ground eigen state, which corresponds to a conventional ballooning mode structure peaking in the outboard mid-plane of tokamaks. However, at strong gradient (H-mode), the most unstable mode is usually not the ground eigen state and the ballooning mode structure becomes unconventional. This result implies that the pedestal of H-mode could have better confinement than L-mode

  18. Innovations in Balloon Catheter Technology in Rhinology.

    Science.gov (United States)

    D'Anza, Brian; Sindwani, Raj; Woodard, Troy D

    2017-06-01

    Since being introduced more than 10 years ago, balloon catheter technology (BCT) has undergone several generations of innovations. From construction to utilization, there has been a myriad of advancements in balloon technology. The ergonomics of the balloon dilation systems have improved with a focus on limiting the extra assembly. "Hybrid" BCT procedures have shown promise in mucosal preservation, including treating isolated complex frontal disease. Multiple randomized clinical trials report improved long-term outcomes in stand-alone BCT, including in-office use. The ever-expanding technological innovations ensure BCT will be a key component in the armamentarium of the modern sinus surgeon. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Wind-Driven Montgolfiere Balloons for Mars

    Science.gov (United States)

    Jones, Jack A.; Fairbrother, Debora; Lemieux, Aimee; Lachenmeier, Tim; Zubrin, Robert

    2005-01-01

    Solar Montgolfiere balloons, or solar-heated hot air balloons have been evaluated by use on Mars for about 5 years. In the past, JPL has developed thermal models that have been confirmed, as well as developed altitude control systems to allow the balloons to float over the landscape or carry ground sampling instrumentation. Pioneer Astronautics has developed and tested a landing system for Montgolfieres. JPL, together with GSSL. have successfully deployed small Montgolfieres (<15-m diameter) in the earth's stratosphere, where conditions are similar to a Mars deployment. Two larger Montgolfieres failed, however, and a series of larger scale Montgolfieres is now planned using stronger, more uniform polyethylene bilaminate, combined with stress-reducing ripstitch and reduced parachute deceleration velocities. This program, which is presently under way, is a joint effort between JPL, WFF, and GSSL, and is planned for completion in three years.

  20. Robotic weather balloon launchers spread in Alaska

    Science.gov (United States)

    Rosen, Julia

    2018-04-01

    Last week, things began stirring inside the truck-size box that sat among melting piles of snow at the airport in Fairbanks, Alaska. Before long, the roof of the box yawned open and a weather balloon took off into the sunny afternoon, instruments dangling. The entire launch was triggered with the touch of a button, 5 kilometers away at an office of the National Weather Service (NWS). The flight was smooth, just one of hundreds of twice-daily balloon launches around the world that radio back crucial data for weather forecasts. But most of those balloons are launched by people; the robotic launchers, which are rolling out across Alaska, are proving to be controversial. NWS says the autolaunchers will save money and free up staff to work on more pressing matters. But representatives of the employee union question their reliability, and say they will hasten the end of Alaska's remote weather offices, where forecasting duties and hours have already been slashed.

  1. Advanced Onboard Energy Storage Solution for Balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced Balloon Programs at NASA are looking for a potential 100 day missions at mid-altitudes. These balloons would be powered by solar panels to take advantage of...

  2. Dry vacuum pumps

    International Nuclear Information System (INIS)

    Sibuet, R

    2008-01-01

    For decades and for ultimate pressure below 1 mbar, oil-sealed Rotary Vane Pumps have been the most popular solution for a wide range of vacuum applications. In the late 80ies, Semiconductor Industry has initiated the development of the first dry roughing pumps. Today SC applications are only using dry pumps and dry pumping packages. Since that time, pumps manufacturers have developed dry vacuum pumps technologies in order to make them attractive for other applications. The trend to replace lubricated pumps by dry pumps is now spreading over many other market segments. For the Semiconductor Industry, it has been quite easy to understand the benefits of dry pumps, in terms of Cost of Ownership, process contamination and up-time. In this paper, Technology of Dry pumps, its application in R and D/industries, merits over conventional pumps and future growth scope will be discussed

  3. Cost-Effectiveness of Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis Versus Surgical Aortic Valve Replacement.

    Science.gov (United States)

    Reynolds, Matthew R; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A; Magnuson, Elizabeth A; Galper, Benjamin Z; Meduri, Christopher U; Arnold, Suzanne V; Baron, Suzanne J; Reardon, Michael J; Adams, David H; Popma, Jeffrey J; Cohen, David J

    2016-01-05

    Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years ([QALY]; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of

  4. Wall stress on ascending thoracic aortic aneurysms with bicuspid compared with tricuspid aortic valve.

    Science.gov (United States)

    Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine

    2018-03-08

    Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid

  5. False coronary dissection with the new Monorail angioplasty balloon catheter.

    Science.gov (United States)

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  6. Particle Astrophysics in NASA's Long Duration Balloon Program

    International Nuclear Information System (INIS)

    Gorham, Peter W.

    2013-01-01

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons

  7. Balloon catheter dilatation of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures.

  8. Balloon catheter dilatation of esophageal strictures

    International Nuclear Information System (INIS)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon

    1990-01-01

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures

  9. Exponential Growth of Nonlinear Ballooning Instability

    International Nuclear Information System (INIS)

    Zhu, P.; Hegna, C. C.; Sovinec, C. R.

    2009-01-01

    Recent ideal magnetohydrodynamic (MHD) theory predicts that a perturbation evolving from a linear ballooning instability will continue to grow exponentially in the intermediate nonlinear phase at the same linear growth rate. This prediction is confirmed in ideal MHD simulations. When the Lagrangian compression, a measure of the ballooning nonlinearity, becomes of the order of unity, the intermediate nonlinear phase is entered, during which the maximum plasma displacement amplitude as well as the total kinetic energy continues to grow exponentially at the rate of the corresponding linear phase.

  10. Performance of the EUSO-Balloon electronics

    International Nuclear Information System (INIS)

    Barrillon, P.; Dagoret, S.; Miyamoto, H.; Moretto, C.; Bacholle, S.; Blaksley, C; Gorodetzky, P.; Jung, A.; Prévôt, G.; Prat, P.; Bayer, J.; Blin, S.; Taille, C. De La; Cafagna, F.; Fornaro, C.; Karczmarczyk, J.; Tanco, G. Medina; Osteria, G.; Perfetto, F.; Park, I.

    2016-01-01

    The 24th of August 2014, the EUSO-Balloon instrument went for a night flight for several hours, 40 km above Timmins (Canada) balloon launching site, concretizing the hard work of an important part of the JEM-EUSO collaboration started 3 years before. This instrument consists of a telescope made of two lenses and a complex electronic chain divided in two main sub-systems: the PDM (Photo Detector Module) and the DP (Data Processor). Each of them is made of several innovative elements developed and tested in a short time. This paper presents their performances before and during the flight

  11. Bovine aortic arch: A novel association with thoracic aortic dilation

    International Nuclear Information System (INIS)

    Malone, C.D.; Urbania, T.H.; Crook, S.E.S.; Hope, M.D.

    2012-01-01

    Aim: To investigate whether there is a link between bovine arch and thoracic aortic aneurysm. Materials and methods: Computed tomography (CT) and magnetic resonance imaging (MRI) images of the thorax of 191 patients with dilated thoracic aortas and 391 consecutive, unselected patients as controls were retrospectively reviewed. Bovine arch was considered present if either a shared origin of the left common carotid and innominate arteries or an origin of the left common carotid from the innominate artery was identified. A chi-square test was used to evaluate the significance of differences between subgroups. Results: A trend towards increased prevalence of bovine arch was seen in patients with dilated aortas (26.2%) compared to controls (20.5%, p = 0.12). The association was statistically significant in patients over 70 years old (31.9%, p = 0.019) and when dilation involved the aortic arch (47.6%, p = 0.003). Conclusions: An association between bovine arch and aortic dilation is seen in older patients, and when dilation involves the aortic arch. Bovine arch should be considered a potential risk factor for thoracic aortic aneurysm.

  12. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    Science.gov (United States)

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  13. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  14. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  15. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  16. Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients

    NARCIS (Netherlands)

    Elattar, Mustafa A.; Vink, Leon W.; van Mourik, Martijn S.; Baan, Jan; Vanbavel, Ed T.; Planken, R. Nils; Marquering, Henk A.

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) is a well-established treatment for patients with severe aortic valve stenosis. This procedure requires pre-operative planning by assessment of aortic dimensions on CT Angiography (CTA). It is well-known that the aortic root dimensions vary over the

  17. Solar Pumping : The Basics

    OpenAIRE

    World Bank Group

    2018-01-01

    Solar photovoltaic water pumping (SWP) uses energy from solar photovoltaic (PV) panels to power an electric water pump. The entire process, from sunlight to stored energy, is elegant and simple. Over last seven years, the technology and price of solar pumping have evolved dramatically and hence the opportunities it presents. Solar pumping is most competitive in regions with high solar inso...

  18. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  19. Bicuspid Aortic Valve Disease: A Comprehensive Review

    OpenAIRE

    Mordi, Ify; Tzemos, Nikolaos

    2012-01-01

    Bicuspid aortic valve is the commonest congenital cardiac abnormality in the general population. This paper article will discuss our current knowledge of the anatomy, pathophysiology, genetics, and clinical aspects of bicuspid aortic valve disease.

  20. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  1. Aortic compliance in patients with aortic regurgitation. Evaluation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murai, Sachiko; Hamada, Seiki; Ueguchi, Takashi

    2005-01-01

    The purpose of this study was to assess by means of cine magnetic resonance imaging (MRI) aortic compliance before and after aortic valve replacement (AVR with SJM (St. Jude Medical, St paul, MN) valve) in patients with aortic regurgitation (AR). Two groups (healthy controls and patients with severe isolated AR) of 10 subjects each were included in this study. Cine MRI was performed at three locations of the aorta, and aortic compliance was calculated by dividing the maximum change in the aortic area by pulse pressure. Cine MRI is useful to assess abnormalities of aortic compliance in patients with AR. Compared with the control group, aortic compliance in the AR group was significantly less in the ascending aorta (p<0.05), decreasing in order of aortic location. After AVR, aortic compliance improved for all locations. Cine MRI enables assessment of aortic biophysical properties such as a compliance for evaluating the progression of AR and the efficacy of treatment. (author)

  2. Abdominal aortic feminism.

    Science.gov (United States)

    Mortimer, Alice Emily

    2014-11-14

    A 79-year-old woman presented to a private medical practice 2 years previously for an elective ultrasound screening scan. This imaging provided the evidence for a diagnosis of an abdominal aortic aneurysm (AAA) to be made. Despite having a number of recognised risk factors for an AAA, her general practitioner at the time did not follow the guidance set out by the private medical professional, that is, to refer the patient to a vascular specialist to be entered into a surveillance programme and surgically evaluated. The patient became symptomatic with her AAA, was admitted to hospital and found to have a tender, symptomatic, 6 cm leaking AAA. She consented for an emergency open AAA repair within a few hours of being admitted to hospital, despite the 50% perioperative mortality risk. The patient spent 4 days in intensive care where she recovered well. She was discharged after a 12 day hospital stay but unfortunately passed away shortly after her discharge from a previously undiagnosed gastric cancer. 2014 BMJ Publishing Group Ltd.

  3. Fasting and meal-suppressed ghrelin levels before and after intragastric balloons and balloon-induced weight loss

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; Eichenberger, R. I.

    2014-01-01

    Intragastric balloons may be an option for obese patients with weight loss failure. Its mode of action remains enigmatic. We hypothesised depressed fasting ghrelin concentrations and enhanced meal suppression of ghrelin secretion by the gastric fundus through balloon contact and balloon-induced

  4. Aortic atresia with normal sized left ventricle

    OpenAIRE

    Priya Jagia; Arun Sharma; Saurabh K Gupta; Munish Guleria

    2016-01-01

    Aortic atresia with an associated ventricular septal defect and adequate sized left ventricle is extremely rare. We present two cases in which an alternate diagnosis was suggested on echocardiography because the hypoplastic aortic trunk was missed due to its small caliber. The final diagnosis was, however, clinched on dual source computed tomography, which not only showed the thin aortic trunk but also clearly depicted the coronary artery origins from the hypoplastic aortic root. To the best ...

  5. A History of Thoracic Aortic Surgery.

    Science.gov (United States)

    McFadden, Paul Michael; Wiggins, Luke M; Boys, Joshua A

    2017-08-01

    Ancient historical texts describe the presence of aortic pathology conditions, although the surgical treatment of thoracic aortic disease remained insurmountable until the 19th century. Surgical treatment of thoracic aortic disease then progressed along with advances in surgical technique, conduit production, cardiopulmonary bypass, and endovascular technology. Despite radical advances in aortic surgery, principles established by surgical pioneers of the 19th century hold firm to this day. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p day device safety, success, and efficacy were noted in 79.1%, 89...

  7. Gender differences in left ventricular function in patients with isolated aortic stenosis.

    Science.gov (United States)

    Favero, Luca; Giordan, Massimo; Tarantini, Giuseppe; Ramondo, Angelo Bruno; Cardaioli, Paolo; Isabella, Giambattista; Chioin, Raffaello; Lupia, Mario; Razzolini, Renato

    2003-05-01

    Hypertrophic response of the left ventricle to systolic overload in aortic stenosis appears to be gender-dependent. To examine gender-related differences in left ventricular (LV) function in patients with isolated severe aortic stenosis, 145 patients (65 women, 80 men; mean age 66 +/- 8 years; range: 50 to 89 years) with aortic valve area 199 mmHg, the mass:volume ratio was increased in men compared with women; of note, the mass:volume ratio in women was not increased in this subgroup compared with the general population. LV pump function in this subgroup was normal and did not differ between men and women. Although no clear-cut difference in hemodynamic parameters was seen, there was a trend towards a less compensatory increase in LV mass in females.

  8. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  9. Percutaneous balloon dilation of pulmonary stenosis

    International Nuclear Information System (INIS)

    Hua Yangde; Huang Ming; Li Jinkang; Qian Jinqing; Chen Xiuyu; Yang Siyuan

    2003-01-01

    Objective: Review our experience of balloon dilation of valvular pulmonary stenosis in 32 cases. Methods: Totally 32 cases of pulmonary stenosis admitted from 1995-2001 with age of 1.5-13 yrs mean 6.8. Diagnosis was made by clinical manifestations, EKG, ECHO and angiocardiography. Results: Before dilation, the mean systolic pressure of right ventricle was (93.5 ± 28.5) mmHg, after the procedure it reduced to (42 ± 9.0) mmHg. The pressure gradient between right ventricle and pulmonary artery before dilation was (76 ± 30) mmHg and become (24.5 ± 8.5) mmHg after dilation. The gradient pressure after dilation was less than 25 mmHg in 90.6% cases. A case of Noonan syndrome showed no response to balloon dilation and died during valvulectomy from accompanying left ventricular cardiomyopathy. Conclusions: Balloon dilation of valvular pulmonary stenosis is effective and safe. The selection of proper diameter of pulmonary valvular rings and sized of the balloon are the major factors

  10. There is a Text in 'The Balloon'

    DEFF Research Database (Denmark)

    Elias, Camelia

    2009-01-01

    From the Introduction: Camelia Elias' "There is a Text in 'The Balloon': Donald Barthelme's Allegorical Flights" provides its reader with a much-need and useful distinction between fantasy and the fantastic: "whereas fantasy in critical discourse can be aligned with allegory, in which a supernatu...

  11. Viscoresistive g-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Paris, R.B.

    1980-01-01

    The resistive G-mode and its particular form, the resistive ballooning mode, are treated as limits of a single simple model. MHD theory including parallel and perpendicular viscosity, finite shear, and finite beta is employed to study their linear stability

  12. Teacher's Guide for Balloons and Gases.

    Science.gov (United States)

    Griffith, Joe H.; And Others

    This guide was developed to provide children with an opportunity to prepare and collect several common gases and to discover and work with some of their properties. The guide is divided into five major sections: (1) introduction, (2) materials, (3) activities, (4) balloons aloft, and (5) an appendix. The introduction provides information…

  13. MHD Ballooning Instability in the Plasma Sheet

    International Nuclear Information System (INIS)

    Cheng, C.Z.; Zaharia, S.

    2003-01-01

    Based on the ideal-MHD model the stability of ballooning modes is investigated by employing realistic 3D magnetospheric equilibria, in particular for the substorm growth phase. Previous MHD ballooning stability calculations making use of approximations on the plasma compressibility can give rise to erroneous conclusions. Our results show that without making approximations on the plasma compressibility the MHD ballooning modes are unstable for the entire plasma sheet where beta (sub)eq is greater than or equal to 1, and the most unstable modes are located in the strong cross-tail current sheet region in the near-Earth plasma sheet, which maps to the initial brightening location of the breakup arc in the ionosphere. However, the MHD beq threshold is too low in comparison with observations by AMPTE/CCE at X = -(8 - 9)R(sub)E, which show that a low-frequency instability is excited only when beq increases over 50. The difficulty is mitigated by considering the kinetic effects of ion gyrorad ii and trapped electron dynamics, which can greatly increase the stabilizing effects of field line tension and thus enhance the beta(sub)eq threshold [Cheng and Lui, 1998]. The consequence is to reduce the equatorial region of the unstable ballooning modes to the strong cross-tail current sheet region where the free energy associated with the plasma pressure gradient and magnetic field curvature is maximum

  14. Teaching Earth Science Using Hot Air Balloons

    Science.gov (United States)

    Kuhl, James; Shaffer, Karen

    2008-01-01

    Constructing model hot air balloons is an activity that captures the imaginations of students, enabling teachers to present required content to minds that are open to receive it. Additionally, there are few activities that lend themselves to integrating so much content across subject areas. In this article, the authors describe how they have…

  15. Balloon-borne radiometer profiler: Field observations

    International Nuclear Information System (INIS)

    Shaw, W.J.; Whiteman, C.D.; Anderson, G.A.; Alzheimer, J.M.; Hubbe, J.M.; Scott, K.A.

    1995-03-01

    This project involves the development of the capability of making routine soundings of broadband radiative fluxes and radiative flux divergences to heights of 1500m AGL. Described in this document are radiometers carried on a stabilized platform in a harness inserted in the tetherline of a tethered balloon meteriological sounding system. Field test results are given

  16. Modified jailed balloon technique for bifurcation lesions.

    Science.gov (United States)

    Saito, Shigeru; Shishido, Koki; Moriyama, Noriaki; Ochiai, Tomoki; Mizuno, Shingo; Yamanaka, Futoshi; Sugitatsu, Kazuya; Tobita, Kazuki; Matsumi, Junya; Tanaka, Yutaka; Murakami, Masato

    2017-12-04

    We propose a new systematic approach in bifurcation lesions, modified jailed balloon technique (M-JBT), and report the first clinical experience. Side branch occlusion brings with a serious complication and occurs in more than 7.0% of cases during bifurcation stenting. A jailed balloon (JB) is introduced into the side branch (SB), while a stent is placed in the main branch (MB) as crossing SB. The size of the JB is half of the MB stent size. While the proximal end of JB attaching to MB stent, both stent and JB are simultaneously inflated with same pressure. JB is removed and then guidewires are recrossed. Kissing balloon dilatation (KBD) and/or T and protrusion (TAP) stenting are applied as needed. Between February 2015 and February 2016, 233 patients (254 bifurcation lesions including 54 left main trunk disease) underwent percutaneous coronary intervention (PCI) using this technique. Procedure success was achieved in all cases. KBD was performed for 183 lesions and TAP stenting was employed for 31 lesions. Occlusion of SV was not observed in any of the patients. Bench test confirmed less deformity of MB stent in M-JBT compared with conventional-JBT. This is the first report for clinical experiences by using modified jailed balloon technique. This novel M-JBT is safe and effective in the preservation of SB patency during bifurcation stenting. © 2017 Wiley Periodicals, Inc.

  17. Thoracic Endovascular Aortic Repair (TEVAR) in Proximal (Type A) Aortic Dissection: Ready for a Broader Application?

    OpenAIRE

    Nienaber, Christoph A.; Sakalihasan, Natzi; Clough, Rachel E.; Aboukoura, Mohamed; Mancuso, Enrico; Yeh, James S.M.; Defraigne, Jean-Olivier; Cheshire, Nick; Rosendahl, Ulrich Peter; Quarto, Cesare; Pepper, John

    2016-01-01

    ObjectiveThoracic endovascular aortic repair (TEVAR) has demonstrated encouraging results and is gaining increasing acceptance as a treatment option for aortic aneurysms and dissections. Yet, its role in managing proximal aortic pathologies is unknown - this is important because in proximal (Stanford type A) aortic dissections, 10-30% are not accepted for surgery, and 30-50% are technically amenable for TEVAR. We describe our case series of type A aortic dissections treated using TEVAR.Method...

  18. The French balloon and sounding rocket space program

    Science.gov (United States)

    Coutin/Faye, S.; Sadourny, I.

    1987-08-01

    Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.

  19. Fluid Dynamics in Rotary Piston Blood Pumps.

    Science.gov (United States)

    Wappenschmidt, Johannes; Sonntag, Simon J; Buesen, Martin; Gross-Hardt, Sascha; Kaufmann, Tim; Schmitz-Rode, Thomas; Autschbach, Ruediger; Goetzenich, Andreas

    2017-03-01

    Mechanical circulatory support can maintain a sufficient blood circulation if the native heart is failing. The first implantable devices were displacement pumps with membranes. They were able to provide a sufficient blood flow, yet, were limited because of size and low durability. Rotary pumps have resolved these technical drawbacks, enabled a growing number of mechanical circulatory support therapy and a safer application. However, clinical complications like gastrointestinal bleeding, aortic insufficiency, thromboembolic complications, and impaired renal function are observed with their application. This is traced back to their working principle with attenuated or non-pulsatile flow and high shear stress. Rotary piston pumps potentially merge the benefits of available pump types and seem to avoid their complications. However, a profound assessment and their development requires the knowledge of the flow characteristics. This study aimed at their investigation. A functional model was manufactured and investigated with particle image velocimetry. Furthermore, a fluid-structure interaction computational simulation was established to extend the laboratory capabilities. The numerical results precisely converged with the laboratory measurements. Thus, the in silico model enabled the investigation of relevant areas like gap flows that were hardly feasible with laboratory means. Moreover, an economic method for the investigation of design variations was established.

  20. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump. 13 refs., 5 figs., 1 tab

  1. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 is pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump

  2. A system for visualization and automatic placement of the endoclamp balloon catheter

    Science.gov (United States)

    Furtado, Hugo; Stüdeli, Thomas; Sette, Mauro; Samset, Eigil; Gersak, Borut

    2010-02-01

    The European research network "Augmented Reality in Surgery" (ARIS*ER) developed a system that supports minimally invasive cardiac surgery based on augmented reality (AR) technology. The system supports the surgical team during aortic endoclamping where a balloon catheter has to be positioned and kept in place within the aorta. The presented system addresses the two biggest difficulties of the task: lack of visualization and difficulty in maneuvering the catheter. The system was developed using a user centered design methodology with medical doctors, engineers and human factor specialists equally involved in all the development steps. The system was implemented using the AR framework "Studierstube" developed at TU Graz and can be used to visualize in real-time the position of the balloon catheter inside the aorta. The spatial position of the catheter is measured by a magnetic tracking system and superimposed on a 3D model of the patient's thorax. The alignment is made with a rigid registration algorithm. Together with a user defined target, the spatial position data drives an actuator which adjusts the position of the catheter in the initial placement and corrects migrations during the surgery. Two user studies with a silicon phantom show promising results regarding usefulness of the system: the users perform the placement tasks faster and more accurately than with the current restricted visual support. Animal studies also provided a first indication that the system brings additional value in the real clinical setting. This work represents a major step towards safer and simpler minimally invasive cardiac surgery.

  3. Adsorption pump for helium pumping out

    International Nuclear Information System (INIS)

    Donde, A.L.; Semenenko, Yu.E.

    1981-01-01

    Adsorption pump with adsorbent cooling by liquid helium is described. Shuttered shield protecting adsorbent against radiation is cooled with evaporating helium passing along the coil positioned on the shield. The pump is also equipped with primed cylindrical shield, cooled with liquid nitrogen. The nitrogen shield has in the lower part the shuttered shield, on the pump casing there is a valve used for pump pre-burning, and valves for connection to recipient as well. Pumping- out rates are presented at different pressures and temperatures of adsorbent. The pumping-out rate according to air at absorbent cooling with liquid nitrogen constituted 5x10 -4 Pa-3000 l/s, at 2x10 -2 Pa-630 l/s. During the absorbent cooling with liquid hydrogen the pumping-out rate according to air was at 4x10 -4 Pa-580 l/s, at 2x10 -3 Pa-680 l/s, according to hydrogen - at 8x10 -5 Pa-2500 l/s, at 5x10 -3 Pa-4200 l/s. During adsorbent cooling with liquid helium the rate of pumping-out according to hydrogen at 3x10 5 Pa-2400% l/s, at 6x10 3 Pa-1200 l/s, and according to helium at 3.5x10 -5 Pa-2800 l/s, at 4x10 -3 Pa-1150 l/s. The limit vacuum is equal to 1x10 -7 Pa. The volume of the vessel with liquid helium is equal to 3.5 l. Helium consumption is 80 cm 3 /h. Consumption of liquid nitrogen from the shield is 400 cm 3 /h. The limit pressure in the pump is obtained after forevacuum pumping-out (adsorbent regeneration) at 300 K temperature. The pump is made of copper. The pump height together with primed tubes is 800 mm diameter-380 mm [ru

  4. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  5. Overview of the NASA balloon R&D program

    Science.gov (United States)

    Smith, I. Steve, Jr.

    1994-01-01

    The catastrophic balloon failure during the first half of the 1980's identified the need for a comprehensive and continuing balloon research and development (R&D) commitment by NASA. Technical understanding was lacking in many of the disciplines and processes associated with scientific ballooning. A comprehensive balloon R&D plan was developed in 1986 and implemented in 1987. The objectives were to develop the understanding of balloon system performance, limitations, and failure mechanisms. The program consisted of five major technical areas: structures, performance and analysis, materials, chemistry and processing, and quality control. Research activitites have been conducted at NASA/Goddard Space Flight Center (GSFC)-Wallops Flight Facility (WFF), other NASA centers and government facilities, universities, and the balloon manufacturers. Several new and increased capabilities and resources have resulted from this activity. The findings, capabilities, and plan of the balloon R&D program are presented.

  6. Continuously pumping and reactivating gas pump

    International Nuclear Information System (INIS)

    Batzer, T.H.; Call, W.R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped

  7. Continuously pumping and reactivating gas pump

    Science.gov (United States)

    Batzer, Thomas H.; Call, Wayne R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  8. Aortic atresia with normal sized left ventricle

    Directory of Open Access Journals (Sweden)

    Priya Jagia

    2016-01-01

    Full Text Available Aortic atresia with an associated ventricular septal defect and adequate sized left ventricle is extremely rare. We present two cases in which an alternate diagnosis was suggested on echocardiography because the hypoplastic aortic trunk was missed due to its small caliber. The final diagnosis was, however, clinched on dual source computed tomography, which not only showed the thin aortic trunk but also clearly depicted the coronary artery origins from the hypoplastic aortic root. To the best of our knowledge, use of multi-detector computed tomography in aortic atresia with well developed left ventricle has not been reported in literature till date.

  9. Resuscitative endovascular balloon occlusion of the aorta: promise, practice, and progress?

    Science.gov (United States)

    Perkins, Zane B; Lendrum, Robbie A; Brohi, Karim

    2016-12-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a minimally invasive damage control procedure for life-threatening abdominal or pelvic haemorrhage. The purpose of this review is to summarize the current understanding and experience with REBOA, outline potential future applications of this technology, and highlight priority areas for further research. REBOA is a feasible method of achieving temporary aortic occlusion and can be performed rapidly, with a high degree of success, in the emergency setting (including at the scene of injury) by appropriately trained clinicians. The procedure supports central perfusion, controls noncompressible haemorrhage, and may improve survival in certain profoundly shocked patient groups; but is also associated with significant risks, including ischaemic tissue damage and procedural complications. Evolutions of this strategy are being explored, with promising proof-of-concept studies in the fields of partial aortic occlusion and the combination of REBOA with extracorporeal support. Noncompressible torso haemorrhage is the leading cause of preventable trauma deaths. The majority of these deaths occur soon after injury, often before any opportunity for definitive haemorrhage control. For a meaningful reduction in trauma mortality, novel methods of rapid haemorrhage control are required.

  10. MMP-2 Isoforms in Aortic Tissue and Serum of Patients with Ascending Aortic Aneurysms and Aortic Root Aneurysms

    Science.gov (United States)

    Tscheuschler, Anke; Meffert, Philipp; Beyersdorf, Friedhelm; Heilmann, Claudia; Kocher, Nadja; Uffelmann, Xenia; Discher, Philipp; Siepe, Matthias; Kari, Fabian A.

    2016-01-01

    Objective The need for biological markers of aortic wall stress and risk of rupture or dissection of ascending aortic aneurysms is obvious. To date, wall stress cannot be related to a certain biological marker. We analyzed aortic tissue and serum for the presence of different MMP-2 isoforms to find a connection between serum and tissue MMP-2 and to evaluate the potential of different MMP-2 isoforms as markers of high wall stress. Methods Serum and aortic tissue from n = 24 patients and serum from n = 19 healthy controls was analyzed by ELISA and gelatin zymography. 24 patients had ascending aortic aneurysms, 10 of them also had aortic root aneurysms. Three patients had normally functioning valves, 12 had regurgitation alone, eight had regurgitation and stenosis and one had only stenosis. Patients had bicuspid and tricuspid aortic valves (9/15). Serum samples were taken preoperatively, and the aortic wall specimen collected during surgical aortic repair. Results Pro-MMP-2 was identified in all serum and tissue samples. Pro-MMP-2 was detected in all tissue and serum samples from patients with ascending aortic/aortic root aneurysms, irrespective of valve morphology or other clinical parameters and in serum from healthy controls. We also identified active MMP-2 in all tissue samples from patients with ascending aortic/aortic root aneurysms. None of the analyzed serum samples revealed signals relatable to active MMP-2. No correlation between aortic tissue total MMP-2 or tissue pro-MMP-2 or tissue active MMP-2 and serum MMP-2 was found and tissue MMP-2/pro-MMP-2/active MMP-2 did not correlate with aortic diameter. This evidence shows that pro-MMP-2 is the predominant MMP-2 species in serum of patients and healthy individuals and in aneurysmatic aortic tissue, irrespective of aortic valve configuration. Active MMP-2 species are either not released into systemic circulation or not detectable in serum. There is no reliable connection between aortic tissue—and serum MMP-2

  11. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  12. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    Science.gov (United States)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  13. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  14. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  16. Is Decellularized Porcine Small Intestine Sub-mucosa Patch Suitable for Aortic Arch Repair?

    Science.gov (United States)

    Corno, Antonio F.; Smith, Paul; Bezuska, Laurynas; Mimic, Branko

    2018-01-01

    Introduction: We reviewed our experience with decellularized porcine small intestine sub-mucosa (DPSIS) patch, recently introduced for congenital heart defects. Materials and Methods: Between 10/2011 and 04/2016 a DPSIS patch was used in 51 patients, median age 1.1 months (5 days to 14.5 years), for aortic arch reconstruction (45/51 = 88.2%) or aortic coarctation repair (6/51 = 11.8%). All medical records were retrospectively reviewed, with primary endpoints interventional procedure (balloon dilatation) or surgery (DPSIS patch replacement) due to patch-related complications. Results: In a median follow-up time of 1.5 ± 1.1 years (0.6–2.3years) in 13/51 patients (25.5%) a re-intervention, percutaneous interventional procedure (5/51 = 9.8%) or re-operation (8/51 = 15.7%) was required because of obstruction in the correspondence of the DPSIS patch used to enlarge the aortic arch/isthmus, with median max velocity flow at Doppler interrogation of 4.0 ± 0.51 m/s. Two patients required surgery after failed interventional cardiology. The mean interval between DPSIS patch implantation and re-intervention (percutaneous procedure or re-operation) was 6 months (1–17 months). While there were 3 hospital deaths (3/51 = 5.9%) not related to the patch implantation, no early or late mortality occurred for the subsequent procedure required for DPSIS patch interventional cardiology or surgery. The median max velocity flow at Doppler interrogation through the aortic arch/isthmus for the patients who did not require interventional procedure or surgery was 1.7 ± 0.57 m/s. Conclusions: High incidence of re-interventions with DPSIS patch for aortic arch and/or coarctation forced us to use alternative materials (homografts and decellularized gluteraldehyde preserved bovine pericardial matrix). PMID:29900163

  17. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  18. Pumps in mining

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    This article looks at the pump industry as a whole, its historical links with the mining industry, their parallel develop ment, and at the individual manufacturers and pumps, services and auxillary products they have to offer.

  19. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  20. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  1. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  2. Retrograde prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Hulbert, J.; Letourneau, J.G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1987-01-01

    The authors performed retrograde prostatic urethroplasty in 18 patients using a 25-mm urethroplasty balloon catheter. The procedure was performed on an outpatient basis under local anesthesia. Voiding cystourethrography, retrograde urethrography, rectal US, and MRE imaging were performed before and immediately after the procedure and at 2 weeks and 3, 6, 12, and 18 months. Long-term results at 18 months and possible clinical implications are discussed

  3. Defining degree of aortic occlusion for partial-REBOA: A computed tomography study on large animals.

    Science.gov (United States)

    Reva, Viktor A; Matsumura, Yosuke; Samokhvalov, Igor M; Pochtarnik, Alexander A; Zheleznyak, Igor S; Mikhailovskaya, Ekaterina M; Morrison, Jonathan J

    2018-04-20

    Partial resuscitative endovascular balloon occlusion of the aorta (P-REBOA) is a modified REBOA technique designed to help ameliorate ischemia-reperfusion injury. The balloon is partially deflated, allowing a proportion of aortic flow distal to the balloon. The aim of this study is to use an ovine model of haemorrhagic shock to correlate the degree of occlusion to several hemodynamic indices. Six sheep weighing 35-46 kg underwent a controlled venous haemorrhage inside a CT scanner until the systolic arterial pressure (AP) dropped to fashion (proximal: r 2  = 0.85, p trend (r 2  = 0.90, p < 0.001). The relationship between percentage occlusion and IBP was sigmoid. MAP values became significantly different at 40-49% occlusion and more (p < 0.01). Furthermore, a drop in the distal pulse pressure from 7.0 (5.5-16.5) to 2.0 (1.5-5.0) mmHg was observed at 80% occlusion. All animals had femoral pulse pressure <5 mmHg at 80% of occlusion and more, which also coincided with the observed loss of pulsatility of the femoral wave-form. Serial CT angiography at an ovine model of haemorrhagic shock demonstrates a correlation between the femoral MAP, F/C pressure gradient and degree of zone I P-REBOA during the staged partial aortic occlusion. These parameters should be considered potential parameters to define the degree of P-REBOA during animal research and clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Long Duration Balloon Charge Controller Stack Integration

    Science.gov (United States)

    Clifford, Kyle

    NASA and the Columbia Scientific Balloon Facility are interested in updating the design of the charge controller on their long duration balloon (LDB) in order to enable the charge controllers to be directly interfaced via RS232 serial communication by a ground testing computers and the balloon's flight computer without the need to have an external electronics stack. The design involves creating a board that will interface with the existing boards in the charge controller in order to receive telemetry from and send commands to those boards, and interface with a computer through serial communication. The inputs to the board are digital status inputs indicating things like whether the photovoltaic panels are connected or disconnected; and analog inputs with information such as the battery voltage and temperature. The outputs of the board are 100ms duration command pulses that will switch relays that do things like connect the photovoltaic panels. The main component of this design is a PIC microcontroller which translates the outputs of the existing charge controller into serial data when interrogated by a ground testing or flight computer. Other components involved in the design are an AD7888 12-bit analog to digital converter, a MAX3232 serial transceiver, various other ICs, capacitors, resistors, and connectors.

  5. Ballooning mode stabilization by moderate sheared rotation

    International Nuclear Information System (INIS)

    Hameiri, E.

    1996-01-01

    Sheared toroidal plasma rotation has been known for some time to have a stabilizing effect on the ballooning modes. A recent calculation showed that a large flow shear, with dΩ/dq of the order of the Alfven toroidal frequency, can stabilize the ballooning modes. This latest result is, in fact, not so optimistic. For observed flows with Mach number of order unity one gets dΩ/dq smaller by a factor O(√β) from the required level (if the flow shear length is of the same order as the magnetic shear length). Moreover, the calculation does not take into account a possibly large transient growth of the mode amplitude due to its Floquet structures We show here that, in fact, there is a general tendency of the ballooning mode to stabilize as soon as the flow shear dΩ/dq exceeds the (O√β smaller) open-quotes slowclose quotes magnetosonic wave frequency. Our analysis is perturbative, where the small parameter is related to the small coupling between the slow and Alfven waves-as is the case in a high aspect-ratio tokamak. (In the perturbation it is important to take the Hamiltonian nature of the governing equations into account.) Moreover, our results apply to the relevant transient growth of the mode amplitude

  6. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  7. Rotary magnetic heat pump

    Science.gov (United States)

    Kirol, L.D.

    1987-02-11

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation. 5 figs.

  8. Vertical pump assembly

    International Nuclear Information System (INIS)

    Dohnal, M.; Rosel, J.; Skarka, V.

    1988-01-01

    The mounting is described of the drive assembly of a vertical pump for nuclear power plants in areas with seismic risk. The assembly is attached to the building floor using flexible and damping elements. The design allows producing seismically resistant pumps without major design changes in the existing types of vertical pumps. (E.S.). 1 fig

  9. Aortic intramural hematoma : assessment of clinical and radiological features in comparison to acute aortic dissection

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Hwang, Jae Cheol; Lee, Jin Seong; Kang, Duk Hyun; Song, Jae Kwan; Song, Koun Sik; Lim, Tae Hwan

    1996-01-01

    To compare the clinical and radiological features of aortic intramural hematoma(IMH) to those of acute aortic dissection(AD). We analyzed the clinical and radiological features of 12 patients with aortic IMH and 43 patients with acute AD. In aortic IMH, the diagnoses were made by means of both CT and transesophageal echocardiography(TEE) and included two surgically proven cases. In acute AD, the diagnoses were made by means of CT and TEE and included 21 surgically proven cases. We compared patients ages, etiologies, the extent of the disease, the presence or absence of aortic branch involvement, complications, and outcomes. Aortic IMH tended to develop in older patients (67.8±7.9 vs. 50.4±13.4, P .05). In aortic IMH, there was no involvement of aortic branches, whereas in acute AD, 14(33%) patients showed involvement of one or more aortic branches. Complications of aortic IMH included pericardial effusion (n=2) and pleural effusion (n=4);in acute AD, pericardial effusion (n=7), pleural effusion (n=4), aortic insufficiency (n=8), cerebral infarction (n=3), renal infarction (n=4) and spinal infarction (n=1) were seen. There was one (8%) death due to aortic IMH and ten (23%) deaths due to acute AD (p<.01). Aortic IMH is characterized by its occurrence in older patients with hypertension, a less frequent incidence of complications, and a more favorable outcome than acute AD

  10. Decreased expression of fibulin-4 in aortic wall of aortic dissection.

    Science.gov (United States)

    Huawei, P; Qian, C; Chuan, T; Lei, L; Laing, W; Wenlong, X; Wenzhi, L

    2014-02-01

    In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10 patients operated for acute ascending aortic dissection and five patients for chronic ascending aortic dissection. Another 15 pieces of samples from patients who had coronary artery bypass were as controls. The aortic samples were stained with aldehyde magenta dyeing to evaluate the arrangement of elastic fibers. The Fibulin-4 protein and mRNA expression were both determined by Western blot and realtime quantitative polymerase chain reaction. Compared with the control group, both in acute and chronic ascending aortic dissection, elastic fiber fragments increased and the expression of fibulin-4 protein significantly decreased (P= 0.045 < 0.05). The level of fibulin-4 mRNA decreased in acute ascending aortic dissection (P= 0.034 < 0.05), while it increased in chronic ascending aortic dissection (P=0.004 < 0.05). The increased amounts of elastic fiber fragments were negatively correlated with the expression of fibulin-4 mRNA in acute ascending aortic dissection. In conclusion, in aortic wall of ascending aortic dissection, the expression of fibulin-4 protein decreased and the expression of fibulin-4 mRNA was abnormal. Fibulin-4 may play an important role in the pathogenesis of aortic dissection.

  11. Molecular and cellular mechanisms of aortic stenosis.

    Science.gov (United States)

    Yetkin, Ertan; Waltenberger, Johannes

    2009-06-12

    Calcific aortic stenosis is the most common cause of aortic valve replacement in developed countries, and this condition increases in prevalence with advancing age. The fibrotic thickening and calcification are common eventual endpoint in both non-rheumatic calcific and rheumatic aortic stenoses. New observations in human aortic valves support the hypothesis that degenerative valvular aortic stenosis is the result of active bone formation in the aortic valve, which may be mediated through a process of osteoblast-like differentiation in these tissues. Additionally histopathologic evidence suggests that early lesions in aortic valves are not just a disease process secondary to aging, but an active cellular process that follows the classical "response to injury hypothesis" similar to the situation in atherosclerosis. Although there are similarities with the risk factor and as well as with the process of atherogenesis, not all the patients with coronary artery disease or atherosclerosis have calcific aortic stenosis. This review mainly focuses on the potential vascular and molecular mechanisms involved in the pathogenesis of aortic valve stenosis. Namely extracellular matrix remodeling, angiogenesis, inflammation, and eventually osteoblast-like differentiation resulting in bone formation have been shown to play a role in the pathogenesis of calcific aortic stenosis. Several mediators related to underlying mechanisms, including growth factors especially transforming growth factor-beta1 and vascular endothelial growth factors, angiogenesis, cathepsin enzymes, adhesion molecules, bone regulatory proteins and matrix metalloproteinases have been demonstrated, however the target to be attacked is not defined yet.

  12. Recent activities on the scientific ballooning in Japan

    International Nuclear Information System (INIS)

    Nisimura, J.; Hirosawa, H.

    1984-01-01

    Scientific ballooning is Japan has been organized by the Institute of Space and Astronautical Science, and about 15 balloons have been launched each year from Sanriku Balloon Center that belongs to this Institute. The balloon center is located in the northern part of Japan. The observations cover the field of X-ray, gamma-ray, infrared astronomy, cosmic rays, and atmospheric science. Systems of lon duration flights such as 'Boomerang Balloons', and fine attitude control systems were developed and widely applied to the scientific observations. International collaborative works were performed in Australia and Indonesia last year. Some details of these activities are reported and possible future collaborations with Braziian balloon group are also discussed. (Author) [pt

  13. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  14. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won

    2005-01-01

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  15. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.A.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. These can generally be classified as: Mechanical; Hydraulic; Tribological; Chemical; and Other (including those associated with the pump driver). Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump

  16. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1981-01-01

    A liquid metal pump comprising a shaft support structure which is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft carries an impeller and the support structure carries an impeller cage which is slidably disposed in a diffuser so as to allow complete removal of pump internals for inspection and repair. The diffuser is concentrically supported in the pump housing which also takes up all reaction forces generated by the discharge of the liquid metal from the diffuser, with floating seals arranged between impeller cage and the diffuser. The space between the diffuser and the pump housing permits the incoming liquid to essentially surround the diffuser. (author)

  17. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  18. Hot air balloons fill gap in atmospheric and sensing platforms

    Science.gov (United States)

    Watson, Steven M.; Price, Russ

    Eric Edgerton was having a problem he could not solve: how to noninvasively collect in situ incinerator plume data. So he called in the Air Force and learned about its Atmospheric and Sensor Test Platform program; its platform is a manned hot air balloon. Many investigators are discovering the advantages of hot air balloons as stable, inexpensive platforms for performing in situ atmospheric measurements. Some are also using remote sensing capabilities on the balloon platforms.

  19. Location and data collection for long stratospheric balloon flights

    Science.gov (United States)

    Malaterre, P.

    Stratospheric balloons capable of taking a 30 kg scientific payload to an altitude of 22 to 30 km for 1 month or more were developed. In-flight experiments were used to qualify the designs of a pumpkin shaped superpressure balloon and an infrared hot air balloon. Tracking of the flights (location and transmission of the parameters measured on board) was achieved using a telemetry gondola including an ARGOS beacon adapted for operation in the low temperatures encountered.

  20. Metabolic and hemodynamic effects of saline infusion to maintain volemia on temporary abdominal aortic occlusion

    Directory of Open Access Journals (Sweden)

    Fábio Ferreira Amorim

    2002-10-01

    Full Text Available OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10 and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10. All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

  1. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  2. Type A Aortic Dissection Presenting with Inferior ST-Elevation Myocardial Infarction.

    Science.gov (United States)

    Wu, Bao-Tzung; Li, Chun-Yi; Chen, Ying-Tsung

    2014-05-01

    Type A aortic dissection with concurrent ST-elevation myocardial infarction (STEMI) is relatively rare. However, it can be potentially fatal and easily misdiagnosed as STEMI alone. Misdiagnosis will lead to inappropriate administration of anticoagulant and thrombolytic therapy and delayed surgical repair of the aorta. In patients with STEMI, short reperfusion time is associated with improved survival, and minimizing the door-to-balloon time is the goal of therapy worldwide. However, signs critical for differential diagnosis may be overlooked in the rush to primary percutaneous coronary intervention. When a patient is encountered who presents with chest pain and ST elevation on electrocardiogram, STEMI should not be the only diagnosis considered. By using bedside available information, detailed history taking and focused physical examination, it is possible to avoid a mistaken diagnosis. Here we report a case of Stanford type A aortic dissection with STEMI that was initially misdiagnosed as sole acute inferior wall myocardial infarction. Patient mortality may have resulted from delayed diagnosis and surgical treatment. Acute myocardial infarction; Aortic dissection.

  3. Aortic root geometry in aortic stenosis patients (a SEAS substudy)

    DEFF Research Database (Denmark)

    Bahlmann, Edda; Nienaber, Christoph A; Cramariuc, Dana

    2011-01-01

    -specified requirements for the aortic root geometry for current available prostheses, CoreValve and Edwards-Sapien. The ratio of sinus of Valsalva height to sinus width was 1:2. In multivariate linear regression analysis, larger sinus of Valsalva height was associated with older age, larger sinus of Valsalva diameter......, lower ejection fraction and smaller supracoronary diameter (multiple R(2) = 0.19, PSapien prosthesis in 66.9%. Overall, annular dimension feasible for TAVI using any available prosthesis was found...

  4. Transcatheter Aortic Valve Replacement by a Novel Suprasternal Approach.

    Science.gov (United States)

    Codner, Pablo; Pugliese, Daniel; Kouz, Rémi; Patel, Amisha; Chen, Cheng-Han; Terre, Juan; Eudailey, Kyle W; Nazif, Tamim; Vahl, Torsten P; George, Isaac; Khalique, Omar K; Hahn, Rebecca T; Leon, Martin B; Kodali, Susheel; Borger, Michael

    2018-04-01

    Transcatheter aortic valve replacement (TAVR) provides therapy for patients with severe aortic stenosis at extreme, high, or intermediate surgical risk. Transfemoral access has been the preferred access route; however, this approach is not suitable for many TAVR candidates. A suprasternal approach may allow for earlier ambulation and shorter hospital stay as compared with other, nontransfemoral approaches. A total of 11 patients with unsuitable transfemoral access underwent suprasternal TAVR. Propensity matching was used to compare suprasternal patients to patients undergoing transaortic, transapical, and trans-subclavian TAVR. Groups were well matched for baseline characteristics. A self-expanding valve device was used in 6 (54.5%) and a balloon-expandable valve in 5 (45.5%) of the 11 patients treated by the suprasternal route. Suprasternal and trans-subclavian patients were able to ambulate earlier than patients treated by the transaortic route, a median 1.6 days (interquartile range [IQR]: 0.9 to 1.8), 1.6 days (IQR: 0.9 to 2.7), and 3.9 days (IQR: 1.9 to 4.5) after the procedure for suprasternal, trans-subclavian, and transaortic patients, respectively (p = 0.001). Length of hospitalization was shorter for patients treated by suprasternal or trans-subclavian access in comparison with patients treated by the transaortic or transapical approach: median 4 days (IQR: 3 to 8) and 4 days (IQR: 4 to 8) versus 8 days (IQR: 6 to 14) and 6 days (IQR: 7 to 11) for suprasternal and trans-subclavian versus transaortic and transapical, respectively (p = 0.01). Suprasternal and trans-subclavian access are associated with earlier ambulation and shorter hospitalization than other nontransfemoral TAVR routes, without an increase in complications. Further study is required to determine if suprasternal is the alternative access of choice for TAVR patients with poor transfemoral vasculature. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  5. Pumps for nuclear facilities

    International Nuclear Information System (INIS)

    1999-01-01

    The guide describes how the Finnish Radiation and Nuclear Safety Authority (STUK) controls pumps and their motors at nuclear power plants and other nuclear facilities. The scope of the control is determined by the Safety Class of the pump in question. The various phases of the control are: (1) review of construction plan, (2) control of manufacturing, and construction inspection, (3) commissioning inspection, and (4) control during operation. STUK controls Safety Class 1, 2 and 3 pumps at nuclear facilities as described in this guide. STUK inspects Class EYT (non-nuclear) pumps separately or in connection with the commissioning inspections of the systems. This guide gives the control procedure and related requirements primarily for centrifugal pumps. However, it is also applied to the control of piston pumps and other pump types not mentioned in this guide

  6. Internal pump monitoring device

    International Nuclear Information System (INIS)

    Kurosaki, Toshikazu.

    1996-01-01

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  7. The role of scientific ballooning for exploration of the magnetosphere

    International Nuclear Information System (INIS)

    Block, L.P.; Lazutin, L.L.; Riedler, W.

    1984-11-01

    The magnetosphere is explored in situ by satellites, but measurements near the low altitude magnetospheric boundary by rockets, balloons and groundbased instruments play a very significant role. The geomagnetic field provides a frame with anisotropic wave and particle propagation effects, enabling remote sensing of the distant magnetosphere by means of balloon-borne and groundbased instruments. Examples will be given of successful studies, with coordinated satellite and balloon observations, of substorm, pulsation and other phenomena propagating both along and across the geomagnetic field. Continued efforts with sophisticated balloon-borne instrumentations should contribute substantially to our understanding of magnetospheric physics. (Author)

  8. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  9. Hyperspectral Polarimeter for Monitoring Balloon Strain, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously unattainable...

  10. An Overview of Current and Future Stratospheric Balloon Mission Capabilities

    Science.gov (United States)

    Smith, Michael

    The modern stratospheric balloon has been used for a variety of missions since the late 1940's. Capabilities of these vehicles to carry larger payloads, fly to higher altitudes, and fly for longer periods of time have increased dramatically over this time. In addition to these basic performance metrics, reliability statistics for balloons have reached unprecedented levels in recent years. Balloon technology developed in the United States in the last decade has the potential to open a new era in economical space science using balloons. As always, the advantage of the balloon platform is the fact that missions can be carried out at a fraction of the cost and schedule of orbital missions. A secondary advantage is the fact that instruments can be re-flown numerous times while upgrading sensor and data processing technologies from year to year. New mission capabilities now have the potential for enabling ground breaking observations using balloons as the primary platform as opposed to a stepping stone to eventual orbital observatories. The limit of very high altitude balloon missions will be explored with respect to the current state of the art of balloon materials and fabrication. The same technological enablers will also be applied to possibilities for long duration missions at mid latitudes with payloads of several tons. The balloon types and their corresponding mission profiles will be presented in a performance matrix that will be useful for potential scientific users in planning future research programs.

  11. [Balloon cell nevi of the conjunctiva (author's transl)].

    Science.gov (United States)

    Schlageter, P E; Daicker, B

    1975-06-01

    The clinical and histological features of three cases of conjunctival balloon cell nevi are described. This peculiar form of nevus is very rare in the conjunctiva. The findings are compared with the descriptions in the literature of dermal balloon cell nevi. They demonstrate, that the conjunctival and dermal tumours are of idential histological structure. The proliferations of the conjunctival epithelium often found in conjunctival nevi do not modify the balloon cell nevi. These can not be diagnosed clinically. The problems of the pathogenesis of the balloon cell nevi are discussed.

  12. The cardiovascular effects of aortic clamping and unclamping

    African Journals Online (AJOL)

    aortic clamping is that afterload and blood pressure increase, and ... individually, albeit they interact with each other. The degree of ... position of the aortic clamp, the greater the increase ... the increase in preload in response to aortic clamping.

  13. Indexing aortic valve area by body surface area increases the prevalence of severe aortic stenosis

    DEFF Research Database (Denmark)

    Jander, Nikolaus; Gohlke-Bärwolf, Christa; Bahlmann, Edda

    2014-01-01

    To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are......To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are...

  14. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...

  15. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-12-31

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  16. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-01-01

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  17. Association Between Gout and Aortic Stenosis.

    Science.gov (United States)

    Chang, Kevin; Yokose, Chio; Tenner, Craig; Oh, Cheongeun; Donnino, Robert; Choy-Shan, Alana; Pike, Virginia C; Shah, Binita D; Lorin, Jeffrey D; Krasnokutsky, Svetlana; Sedlis, Steven P; Pillinger, Michael H

    2017-02-01

    An independent association between gout and coronary artery disease is well established. The relationship between gout and valvular heart disease, however, is unclear. The aim of this study was to assess the association between gout and aortic stenosis. We performed a retrospective case-control study. Aortic stenosis cases were identified through a review of outpatient transthoracic echocardiography (TTE) reports. Age-matched controls were randomly selected from patients who had undergone TTE and did not have aortic stenosis. Charts were reviewed to identify diagnoses of gout and the earliest dates of gout and aortic stenosis diagnosis. Among 1085 patients who underwent TTE, 112 aortic stenosis cases were identified. Cases and nonaortic stenosis controls (n = 224) were similar in age and cardiovascular comorbidities. A history of gout was present in 21.4% (n = 24) of aortic stenosis subjects compared with 12.5% (n = 28) of controls (unadjusted odds ratio 1.90, 95% confidence interval 1.05-3.48, P = .038). Multivariate analysis retained significance only for gout (adjusted odds ratio 2.08, 95% confidence interval 1.00-4.32, P = .049). Among subjects with aortic stenosis and gout, gout diagnosis preceded aortic stenosis diagnosis by 5.8 ± 1.6 years. The age at onset of aortic stenosis was similar among patients with and without gout (78.7 ± 1.8 vs 75.8 ± 1.0 years old, P = .16). Aortic stenosis patients had a markedly higher prevalence of precedent gout than age-matched controls. Whether gout is a marker of, or a risk factor for, the development of aortic stenosis remains uncertain. Studies investigating the potential role of gout in the pathophysiology of aortic stenosis are warranted and could have therapeutic implications. Published by Elsevier Inc.

  18. Supra-annular structure assessment for self-expanding transcatheter heart valve size selection in patients with bicuspid aortic valve.

    Science.gov (United States)

    Liu, Xianbao; He, Yuxin; Zhu, Qifeng; Gao, Feng; He, Wei; Yu, Lei; Zhou, Qijing; Kong, Minjian; Wang, Jian'an

    2018-04-01

    To explore assessment of supra-annular structure for self-expanding transcatheter heart valve (THV) size selection in patients with bicuspid aortic stenosis (AS). Annulus-based device selection from CT measurement is the standard sizing strategy for tricuspid aortic valve before transcatheter aortic valve replacement (TAVR). Because of supra-annular deformity, device selection for bicuspid AS has not been systemically studied. Twelve patients with bicuspid AS who underwent TAVR with self-expanding THVs were included in this study. To assess supra-annular structure, sequential balloon aortic valvuloplasty was performed in every 2 mm increments until waist sign occurred with less than mild regurgitation. Procedural results and 30 day follow-up outcomes were analyzed. Seven patients (58.3%) with 18 mm; three patients (25%) with sequential 18 mm, 20 mm; and only two patients (16.7%) with sequential 18 mm, 20 mm, and 22 mm balloon sizing were performed, respectively. According to the results of supra-annular assessment, a smaller device size (91.7%) was selected in all but one patient compared with annulus based sizing strategy, and the outcomes were satisfactory with 100% procedural success. No mortality and 1 minor stroke were observed at 30 d follow-up. The percentage of NYHA III/IV decreased from 83.3% (9/12) to 16.7% (2/12). No new permanent pacemaker implantation and no moderate or severe paravalvular leakage were found. A supra-annular structure based sizing strategy is feasible for TAVR in patients with bicuspid AS. © 2018 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  19. Low-gradient aortic stenosis.

    Science.gov (United States)

    Clavel, Marie-Annick; Magne, Julien; Pibarot, Philippe

    2016-09-07

    An important proportion of patients with aortic stenosis (AS) have a 'low-gradient' AS, i.e. a small aortic valve area (AVA gradient (gradient discrepancy raises uncertainty about the actual stenosis severity and thus about the indication for aortic valve replacement (AVR) if the patient has symptoms and/or left ventricular (LV) systolic dysfunction. The most frequent cause of low-gradient (LG) AS is the presence of a low LV outflow state, which may occur with reduced left ventricular ejection fraction (LVEF), i.e. classical low-flow, low-gradient (LF-LG), or preserved LVEF, i.e. paradoxical LF-LG. Furthermore, a substantial proportion of patients with AS may have a normal-flow, low-gradient (NF-LG) AS: i.e. a small AVA-low-gradient combination but with a normal flow. One of the most important clinical challenges in these three categories of patients with LG AS (classical LF-LG, paradoxical LF-LG, and NF-LG) is to differentiate a true-severe AS that generally benefits from AVR vs. a pseudo-severe AS that should be managed conservatively. A low-dose dobutamine stress echocardiography may be used for this purpose in patients with classical LF-LG AS, whereas aortic valve calcium scoring by multi-detector computed tomography is the preferred modality in those with paradoxical LF-LG or NF-LG AS. Although patients with LF-LG severe AS have worse outcomes than those with high-gradient AS following AVR, they nonetheless display an important survival benefit with this intervention. Some studies suggest that transcatheter AVR may be superior to surgical AVR in patients with LF-LG AS. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  20. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    Science.gov (United States)

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  1. Thoracic aortic aneurysms and dissections: endovascular treatment.

    Science.gov (United States)

    Baril, Donald T; Cho, Jae S; Chaer, Rabih A; Makaroun, Michel S

    2010-01-01

    The treatment of thoracic aortic disease has changed radically with the advances made in endovascular therapy since the concept of thoracic endovascular aortic repair was first described 15 years ago. Currently, there is a diverse array of endografts that are commercially available to treat the thoracic aorta. Multiple studies, including industry-sponsored and single-institution reports, have demonstrated excellent outcomes of thoracic endovascular aortic repair for the treatment of thoracic aortic aneurysms, with less reported perioperative morbidity and mortality in comparison with conventional open repair. Additionally, similar outcomes have been demonstrated for the treatment of type B dissections. However, the technology remains relatively novel, and larger studies with longer term outcomes are necessary to more fully evaluate the role of endovascular therapy for the treatment of thoracic aortic disease. This review examines the currently available thoracic endografts, preoperative planning for thoracic endovascular aortic repair, and outcomes of thoracic endovascular aortic repair for the treatment of both thoracic aortic aneurysms and type B aortic dissections. Mt Sinai J Med 77:256-269, 2010. (c) 2010 Mount Sinai School of Medicine.

  2. Hybrid treatment of penetrating aortic ulcer

    International Nuclear Information System (INIS)

    Lara, Juan Antonio Herrero; Martins-Romeo, Daniela de Araujo; Escudero, Carlos Caparros; Falcon, Maria del Carmen Prieto; Batista, Vinicius Bianchi; Vazquez, Rosa Maria Lepe

    2015-01-01

    Penetrating atherosclerotic aortic ulcer is a rare entity with poor prognosis in the setting of acute aortic syndrome. In the literature, cases like the present one, located in the aortic arch, starting with chest pain and evolving with dysphonia, are even rarer. The present report emphasizes the role played by computed tomography in the diagnosis of penetrating atherosclerotic ulcer as well as in the differentiation of this condition from other acute aortic syndromes. Additionally, the authors describe a new therapeutic approach represented by a hybrid endovascular surgical procedure for treatment of the disease. (author)

  3. Hybrid treatment of penetrating aortic ulcer

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Juan Antonio Herrero; Martins-Romeo, Daniela de Araujo; Escudero, Carlos Caparros; Falcon, Maria del Carmen Prieto; Batista, Vinicius Bianchi, E-mail: jaherrero5@hotmail.com [Unidade de Gestao Clinica (UGC) de Diagnostico por Imagem - Hosppital Universitario Virgen Macarena, Sevilha (Spain); Vazquez, Rosa Maria Lepe [Unit of Radiodiagnosis - Hospital Nuestra Senora de la Merced, Osuna, Sevilha (Spain)

    2015-05-15

    Penetrating atherosclerotic aortic ulcer is a rare entity with poor prognosis in the setting of acute aortic syndrome. In the literature, cases like the present one, located in the aortic arch, starting with chest pain and evolving with dysphonia, are even rarer. The present report emphasizes the role played by computed tomography in the diagnosis of penetrating atherosclerotic ulcer as well as in the differentiation of this condition from other acute aortic syndromes. Additionally, the authors describe a new therapeutic approach represented by a hybrid endovascular surgical procedure for treatment of the disease. (author)

  4. Surgery for acute Type I aortic dissection without resection of supra-aortic entry sites leads to unfavourable aortic remodelling.

    Science.gov (United States)

    Heo, Woon; Song, Suk-Won; Lee, Kwang-Hun; Lee, Shin-Young; Kim, Tae-Hoon; Baek, Min-Young; Yoo, Kyung-Jong

    2018-01-29

    This study aimed to evaluate the impact of remnant re-entries in arch branches on postoperative change in the aortic arch and descending aortic diameters and the rate of major adverse aortic events. Between January 2010 and December 2016, 249 patients underwent surgery for acute Type I aortic dissection. Patients who underwent total arch replacement, had Marfan syndrome or had intramural haematoma were excluded. Seventy-two patients with predischarge and follow-up computed tomography scans were enrolled. Patients with and without re-entries in the arch branches after surgery were assigned to the supra-aortic entry (SAE, n = 21) and no supra-aortic entry (n = 51) groups, respectively. Diameters were measured at 7 levels: the innominate artery, left common carotid artery, left subclavian artery, 20 mm distal to the left subclavian artery, pulmonary artery bifurcation, coeliac axis and maximal diameter of the descending thoracic aorta. Growth rates at the levels of the pulmonary artery bifurcation and 20 mm distal to the left subclavian artery were significantly higher in the SAE group than in the no supra-aortic entry group. The rate of freedom from major adverse aortic events (annual growth >5 mm or maximal diameter of the descending thoracic aorta >50 mm) at 5 years was significantly higher in the no supra-aortic entry group than in the SAE group. Remnant SAE leads to unfavourable aortic remodelling after acute Type I aortic dissection repair. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Thrombus aspiration catheter is a Dottering balloon

    Directory of Open Access Journals (Sweden)

    D. Sheshagiri Rao

    2016-07-01

    Full Text Available Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate?

  6. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  7. Retrograde transurethral balloon dilation of the prostate

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Wasserman, N.F.; Lund, G.; Hulbert, J.; Hunter, D.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1986-01-01

    A series of patients with documented benign prostatic hypertrophy evaluated by urodynamic studies, voiding cystourethrography, retrograde urethrography, and MR imaging underwent dilation performed using a retrograde transurethral approach with 25-mm balloon dilators inflated at a pressure of 3-4 atm for 10 minutes. Immediately after the procedure, retrograde and voiding cystourethrography as well as MR imaging were performed. A Foley catheter was left in place for 24 hours. Complete relief of symptoms has occurred in all of the patients during the follow-up period. No significant complications other than transient hematuria resulted from the procedure. Results of the comparison studies and of MR imaging are discussed

  8. Early results of valve-sparing ascending aortic replacement in type A aortic dissection and aortic insufficiency

    Directory of Open Access Journals (Sweden)

    М. Л. Гордеев

    2016-08-01

    Full Text Available Aim: The study was designed to investigate predictors of effective valve-sparing ascending aortic replacement in patients with Stanford type A aortic dissection combined with aortic insufficiency and to analyze efficacy and safety of this kind of surgery.Methods: From January 2010 to December 2015, 49 patients with Stanford type A aortic dissection combined with aortic insufficiency underwent ascending aortic replacement. All patients were divided into 3 groups: valve-sparing procedures (group 1, n = 11, combined aortic valve and supracoronary ascending aortic replacement (group 2, n = 12, and Bentall procedure (group 3, n = 26. We assessed the initial status of patients, incidence of complications and efficacy of valve-sparing ascending aortic replacement.Results: The hospital mortality rate was 8.2% (4/49 patients. The amount of surgical correction correlated with the initial diameter of the aorta at the level of the sinuses of Valsalva. During the hospital period, none of patients from group 1 developed aortic insufficiency exceeding Grade 2 and the vast majority of patients had trivial aortic regurgitation. The parameters of cardiopulmonary bypass, cross-clamp time and circulatory arrest time did not correlate with the initial size of the ascending aorta and aortic valve blood flow impairment, neither did they influence significantly the incidence and severity of neurological complications. The baseline size of the ascending aorta and degree of aortic regurgitation did not impact the course of the early hospital period.Conclusions: Supracoronary ascending aortic replacement combined with aortic valve repair in ascending aortic dissection and aortic regurgitation is effective and safe. The initial size of the ascending aorta and aortic arch do not influence immediate results. The diameter of the aorta at the level of the sinuses of Valsalva and the condition of aortic valve leaflets could be considered as the limiting factors. Further long

  9. [Metabolic syndrome and aortic stiffness].

    Science.gov (United States)

    Simková, A; Bulas, J; Murín, J; Kozlíková, K; Janiga, I

    2010-09-01

    The metabolic syndrome (MS) is a cluster of risk factors that move the patient into higher level of risk category of cardiovascular disease and the probability of type 2 diabetes mellitus manifestation. Definition of MS is s based on the presence of selected risk factors as: abdominal obesity (lager waist circumpherence), atherogenic dyslipidemia (low value of HDL-cholesterol and increased level of triglycerides), increased fasting blood glucose (or type 2 DM diagnosis), higher blood pressure or antihypertensive therapy. In 2009 there were created harmonizing criteria for MS definition; the condition for assignment of MS is the presence of any 3 criteria of 5 mentioned above. The underlying disorder of MS is an insulin resistance or prediabetes. The patients with MS more frequently have subclinical (preclinical) target organ disease (TOD) which is the early sings of atherosclerosis. Increased aortic stiffness is one of the preclinical diseases and is defined by pathologically increased carotidofemoral pulse wave velocity in aorta (PWV Ao). With the aim to assess the influence of MS on aortic stiffness we examined the group of women with arterial hypertension and MS and compare them with the group of women without MS. The aortic stiffness was examined by Arteriograph--Tensiomed, the equipment working on the oscillometric principle in detection of pulsations of brachial artery. This method determines the global aortic stiffness based on the analysis of the shape of pulse curve of brachial artery. From the cohort of 49 pts 31 had MS, the subgroups did not differ in age or blood pressure level. The mean number of risk factors per person in MS was 3.7 comparing with 1.7 in those without MS. In the MS group there was more frequently abdominal obesity present (87% vs 44%), increased fasting blood glucose (81% vs 22%) and low HDL-cholesterol level. The pulse wave velocity in aorta, PWV Ao, was significantly higher in patients with MS (mean value 10,19 m/s vs 8,96 m

  10. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  11. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Electrokinetic pumps and actuators

    International Nuclear Information System (INIS)

    Phillip M. Paul

    2000-01-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps

  13. Electrokinetic pumps and actuators

    Energy Technology Data Exchange (ETDEWEB)

    Phillip M. Paul

    2000-03-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps.

  14. Aortic elongation in aortic aneurysm and dissection: the Tübingen Aortic Pathoanatomy (TAIPAN) project.

    Science.gov (United States)

    Krüger, Tobias; Sandoval Boburg, Rodrigo; Lescan, Mario; Oikonomou, Alexandre; Schneider, Wilke; Vöhringer, Luise; Lausberg, Henning; Bamberg, Fabian; Blumenstock, Gunnar; Schlensak, Christian

    2018-01-24

    To study the lengths and diameters of aortic segments in healthy and diseased aortas and to assess the role of aortic elongation in Type A aortic dissection (TAD) prediction. Ectasia and aneurysm were defined by ascending aorta diameters of 45-54 mm and ≥55 mm, respectively. Computed tomography angiography studies of 256 healthy, 102 ectasia, 38 aneurysm, 17 pre-TAD and 166 TAD aortas were analysed using curved multiplanar reformats. The study groups were structurally equal. The diameter of the ascending aorta was 35 mm in the control group and was larger (P TAD (43 mm) and TAD (56 mm) groups. The length of the ascending aorta from the aortic annulus to the brachiocephalic trunk was 92 mm in the control group, 113 mm in the ectasia group, 120 mm in the aneurysm group and 111 mm and 118 mm in the pre-TAD and TAD groups (all P TAD group and 48% of the TAD group. The correlation between the diameter and the length of the ascending aorta was r = 0.752; therefore, both parameters must be examined separately. A score considering both parameters identified 23.5% of pre-TAD patients, significantly more than the diameter alone, and 31.4% of ectasia aortas were elongated. Patients with ectatic (45-54 mm diameter) and elongated (≥120 mm) ascending aortas represent a high-risk subpopulation for TAD. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Detection of pump degradation

    International Nuclear Information System (INIS)

    Greene, R.H.; Casada, D.A.; Ayers, C.W.

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented

  16. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  17. External caps: An approach to stress reduction in balloons

    Science.gov (United States)

    Hazlewood, K. H.

    Recent findings of the catastrophic balloon failures investigation in the U.S.A. indicate that very large gross inflations, in balloons using present design philosophy, over-stress currently available materials. External caps are proposed as an economic approach to reducting those stresses to an acceptable level.

  18. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    Science.gov (United States)

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2014-04-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  19. Infected aortic aneurysm and inflammatory aortic aneurysm. In search of an optimal differential diagnosis

    International Nuclear Information System (INIS)

    Ishizaka, Nobukazu; Sohmiya, Koichi; Miyamura, Masatoshi; Umeda, Tatsuya; Tsuji, Motomu; Katsumata, Takahiro; Miyata, Tetsuro

    2012-01-01

    Infected aortic aneurysm and inflammatory aortic aneurysm each account for a minor fraction of the total incidence of aortic aneurysm and are associated with periaortic inflammation. Despite the similarity, infected aortic aneurysm generally shows a more rapid change in clinical condition, leading to a fatal outcome; in addition, delayed diagnosis and misuse of corticosteroid or immunosuppressing drugs may lead to uncontrolled growth of microorganisms. Therefore, it is mandatory that detection of aortic aneurysm is followed by accurate differential diagnosis. In general, infected aortic aneurysm appears usually as a saccular form aneurysm with nodularity, irregular configuration; however, the differential diagnosis may not be easy sometimes for the following reasons: symptoms, such as abdominal and/or back pain and fever, and blood test abnormalities, such as elevated C-reactive protein and enhanced erythrocyte sedimentation rate, are common in infected aortic aneurysm, but they are not found infrequently in inflammatory aortic aneurysm; some inflammatory aortic aneurysms are immunoglobulin (Ig) G4-related, but not all of them; the prevalence of IgG4 positivity in infected aortic aneurysm has not been well investigated; enhanced uptake of 18F-fluorodeoxyglucose (FDG) by 18F-FDG-positron emission tomography may not distinguish between inflammation mediated by autoimmunity and that mediated by microorganism infection. Here we discuss the characteristics of these two forms of aortic aneurysm and the points of which we have to be aware before reaching a final diagnosis. (author)

  20. Thermomechanical piston pump development

    Science.gov (United States)

    Sabelman, E. E.

    1971-01-01

    A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.

  1. Pumps for nuclear industry

    International Nuclear Information System (INIS)

    Tanguy, L.

    1978-01-01

    In order to meet the requirements of nuclear industry for the transfer of corrosive, toxic, humidity sensitive or very pure gases, different types of pumps were developped and commercialized. Their main characteristics are to prevent pollution of the transfered fluid by avoiding any contact between this fluid and the lubricated parts of the machine, and to prevent a contamination of the atmosphere or of the fluid by a total tightness. Patellar pumps have been particularly developped because the metallic bellows are quite reliable and resistant in this configuration. Two types are described: patellar pumps without friction and barrel pumps whose pistons are provided with rings sliding in the cylinders without lubrication [fr

  2. Pump safety device

    International Nuclear Information System (INIS)

    Timmermans, Francis; Vandervorst, Jean.

    1981-01-01

    Safety device for longitudinally leak proofing the shaft of a pump in the event of the fracture of the dynamic seal separating the pump fluid high pressure chamber from the low pressure chamber. It is designed for fitting to the primary pumps of nuclear reactors. It includes a hollow cyclindrical piston located coaxially around the pump shaft and normally housed in a chamber provided for this purpose in the fixed housing of the dynamic seal, and means for moving this piston coaxially so as to compress a safety O ring between the shaft and the piston in the event of the dynamic seal failing [fr

  3. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  4. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1995-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  5. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  6. Delayed Presentation of a Giant Ascending Aortic Aneurysm following Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Tugrul Göncü

    2009-01-01

    Full Text Available Giant ascending aortic aneurysm formation following aortic valve replacement is rare. A 28-year-old man who underwent aortic valve replacement with a prosthetic valve for aortic regurgitation secondary to congenital bicuspid aortic valve about 10 years ago was diagnosed with a giant ascending aortic aneurysm about 16 cm in diameter in follow-up. The aneurysm was resected leaving the functional old mechanical prosthesis in place and implanted a 34-mm Hemashield woven graft, associated with the left and right coronary artery button implantation. Histological findings of the aortic aneurysm wall showed cystic medial necrosis. The postoperative course was uneventful and postoperative examination demonstrated good surgical results.

  7. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.

    1988-01-01

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  8. Balloon catheter dilation of benign esophageal stenosis in children

    International Nuclear Information System (INIS)

    Fan Guoping; Yu Juming; Zhong Weixing; Zhu Ming; Wu Yeming; Shi Chengren

    2001-01-01

    Objective: To evaluate the methods and effect of balloon catheter dilation of benign esophageal stenosis in children. Methods: 9 cases had an anastomotic stenosis after surgical correction of esophageal atresia; 11 cases of esophageal stenosis due to ingestion of caustics; one case had an lower esophageal stenosis after Nissen surgery and one case after gastro-esophagoplasty. Age ranged from 17 days to 7 years. Each case had a barium esophagram before balloon dilation. The balloon size varied from 3 to 10 mm in diameter. Results: 21 cases were successful after dilation of balloon catheter. There were no esophageal perforation and complications. The satisfactory results maintained from six months to thirty months. Conclusions: Balloon catheter dilation is a simple, safe and reliable method for the treatment of benign esophageal strictures in children as the first choice

  9. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  10. Balloon observation of gamma-ray burst

    International Nuclear Information System (INIS)

    Nishimura, Jun; Fujii, Masami; Yamagami, Takamasa; Oda, Minoru; Ogawara, Yoshiaki

    1978-01-01

    Cosmic gamma-ray burst is an interesting high energy astrophysical phenomenon, but the burst mechanism has not been well understood. Since 1975, long duration balloon flight has been conducted to search for gamma-ray bursts and to determine the source locations. A rotating cross-modulation collimator was employed to determine the locations of sources, and four NaI(Tl) scintillation counters were employed to detect hard X-ray with energy from 20 to 200 keV. The balloon light was performed at altitude of 8.3 mb from September 28, 1977, and the observation time of 79 hours was achieved. In this experiment, the monitor counter was not mounted. The count increase was observed at 16 h 22 m 31 s JST on October 1, 1977. The event disappeared after 1 sec. The total flux is estimated to be 1.6 x 10 -6 erg/cm 2 sec at the top of the atmosphere. When this event was observed, the solar-terrestrial environment was also quiet. Thus, this event was attributed to a small gamma-ray burst. Unfortunately, the duration of the burst was so short that the position of the burst source was not able to be determined. (Yoshimori, M.)

  11. Spectrum of the ballooning Schroedinger equation

    International Nuclear Information System (INIS)

    Dewar, R.L.

    1997-01-01

    The ballooning Schroedinger equation (BSE) is a model equation for investigating global modes that can, when approximated by a Wentzel-Kramers-Brillouin (WKB) ansatz, be described by a ballooning formalism locally to a field line. This second order differential equation with coefficients periodic in the independent variable θ k is assumed to apply even in cases where simple WKB quantization conditions break down, thus providing an alternative to semiclassical quantization. Also, it provides a test bed for developing more advanced WKB methods: e.g. the apparent discontinuity between quantization formulae for open-quotes trappedclose quotes and open-quotes passingclose quotes modes, whose ray paths have different topologies, is removed by extending the WKB method to include the phenomena of tunnelling and reflection. The BSE is applied to instabilities with shear in the real part of the local frequency, so that the dispersion relation is inherently complex. As the frequency shear is increased, it is found that trapped modes go over to passing modes, reducing the maximum growth rate by averaging over θ k

  12. Transcatheter Aortic Valve Replacement in Europe

    DEFF Research Database (Denmark)

    Mylotte, Darren; Osnabrugge, Ruben L J; Windecker, Stephan

    2013-01-01

    The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy.......The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy....

  13. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  14. Severe aortic stenosis: diagnosis, treatment and prognosis

    NARCIS (Netherlands)

    M.W.A. van Geldorp (Martijn)

    2013-01-01

    textabstractDegenerative aortic stenosis is the most common valvular heart disease in developed countries. The prevalence of severe aortic stenosis increases with age from 1% in people below 65 years of age to nearly 6% in people over the age of 85. Since the population life expectancy continues to

  15. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  16. New concepts for interplanetary balloons and blimps, particularly for Titan

    Science.gov (United States)

    Nott, J.

    This paper proposes novel approaches for balloons for planets Titan BALLUTE A balloon or blimp arriving at a planet or moon with an atmosphere might inflate falling under a parachute or after landing Neither is ideal In both cases the envelope must include qualities needed for inflation as well as those for flight A ballute BALLoon parachUTE could be used thus a ballute is like a hot air balloon with a large mouth Initially it fills by ram pressure descending through an atmosphere As proposed it would then be heated by solid propellant It would stop descending and float level with hot air lift It is now a perfect location for inflation without wind or movement through the atmosphere and away from the uncertainties of the surface A ballute could be used over several bodies in the solar system BALLOONS FOR LOW TEMPERATURES Flight in very low temperatures is also discussed Conditions are so different that it is useful to examine basic factors These apply for any planet with low temperature and weather calm enough for balloons or blimps First for terrestrial hot air balloons thermal radiation is usually the dominant way heat is lost But radiation rises with the 4th power of absolute temperature At Titan radiation will be one or two orders of magnitude smaller Also the dense atmosphere allows small balloons small temperature differences So convection is small It appears a hot air balloon can easily be heated by a radioactive source likely carried to make electricity Pinholes are not important in such a balloon

  17. Aorta Balloon Occlusion in Trauma: Three Cases Demonstrating Multidisciplinary Approach Already on Patient’s Arrival to the Emergency Room

    International Nuclear Information System (INIS)

    Hörer, Tal M.; Hebron, Dan; Swaid, Forat; Korin, Alexander; Galili, Offer; Alfici, Ricardo; Kessel, Boris

    2016-01-01

    PurposeTo describe the usage of aortic balloon occlusion (ABO), based on a multidisciplinary approach in severe trauma patients, emphasizing the role of the interventional radiologist in primary trauma care.MethodsWe briefly discuss the relevant literature, the technical aspects of ABO in trauma, and a multidisciplinary approach to the bleeding trauma patient. We describe three severely injured trauma patients for whom ABO was part of initial trauma management.ResultsThree severely injured multi-trauma patients were treated by ABO as a bridge to surgery and embolization. The procedures were performed by an interventional radiologist in the early stages of trauma management.ConclusionsThe interventional radiologist and the multidisciplinary team approach can be activated already on severe trauma patient arrival. ABO usage and other endovascular methods are becoming more widely spread, and can be used early in trauma management, without delay, thus justifying the early activation of this multidisciplinary approach

  18. Aorta Balloon Occlusion in Trauma: Three Cases Demonstrating Multidisciplinary Approach Already on Patient’s Arrival to the Emergency Room

    Energy Technology Data Exchange (ETDEWEB)

    Hörer, Tal M., E-mail: tal.horer@orebroll.se [Örebro University, Department of Cardiothoracic and Vascular Surgery, Örebro University Hospital (Sweden); Hebron, Dan [Hillel Yaffe Medical Center, Department of Radiology (Israel); Swaid, Forat [Bnai-Zion Medical Center, Department of General Surgery (Israel); Korin, Alexander [Hillel Yaffe Medical Center, Trauma Unit (Israel); Galili, Offer [Hillel Yaffe Medical Center, Department of Vascular Surgery (Israel); Alfici, Ricardo [Hillel Yaffe Medical Center, Surgical Division (Israel); Kessel, Boris [Hillel Yaffe Medical Center, Trauma Unit (Israel)

    2016-02-15

    PurposeTo describe the usage of aortic balloon occlusion (ABO), based on a multidisciplinary approach in severe trauma patients, emphasizing the role of the interventional radiologist in primary trauma care.MethodsWe briefly discuss the relevant literature, the technical aspects of ABO in trauma, and a multidisciplinary approach to the bleeding trauma patient. We describe three severely injured trauma patients for whom ABO was part of initial trauma management.ResultsThree severely injured multi-trauma patients were treated by ABO as a bridge to surgery and embolization. The procedures were performed by an interventional radiologist in the early stages of trauma management.ConclusionsThe interventional radiologist and the multidisciplinary team approach can be activated already on severe trauma patient arrival. ABO usage and other endovascular methods are becoming more widely spread, and can be used early in trauma management, without delay, thus justifying the early activation of this multidisciplinary approach.

  19. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    Science.gov (United States)

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  20. Performance of Wind Pump Prototype

    African Journals Online (AJOL)

    Mulu

    Mekelle University, Mekelle, Ethiopia (*mul_at@yahoo.com). ABSTRACT. A wind ... balanced rotor power and reciprocating pump, hence did not consider the effect of pump size. ... Keywords: Wind pump, Windmill, Performance testing, Pump efficiency, Pump discharge, ... Unfortunately, in rural places, where the houses are.

  1. MRI evaluation of the aortic disease

    International Nuclear Information System (INIS)

    Kapuscinski, O.; Polkowski, J.; Zaleska, T.; Walecki, J.; Biesiadko, M.

    1994-01-01

    The goal of our study was to establish the value of MRI in diagnosing aortic disease. During 3 years period 46 patients were examined (12 women aged from 6 to 62 years and 34 men aged from 8 to 72 years). In 28 cases the thoracic aorta was examined, in 6 cases the abdominal aorta and in 12 - both the thoracic and the abdominal aorta. MR images were performed on MRT 50 A Toshiba unit 0.5 T. MR images demonstrated aortic aneurysm (caused by atherosclerosis or trauma), aortic dissections, aortic anomalies (i.e. in Turner syndrome) and non-specific aortitis and vasculitis. We regard MRI as preferable noninvasive imaging technique in diagnosing aortic disease. (author)

  2. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous spectral vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition: advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  3. Treatment strategy for ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Davidovic, L

    2014-07-01

    Rupture is the most serious and lethal complication of the abdominal aortic aneurysm. Despite all improvements during the past 50 years, ruptured abdominal aortic aneurysms are still associated with very high mortality. Namely, including patients who die before reaching the hospital, the mortality rate due to abdominal aortic aneurysm rupture is 90%. On the other hand, during the last twenty years, the number of abdominal aortic aneurysms significantly increased. One of the reasons is the fact that in majority of countries the general population is older nowadays. Due to this, the number of degenerative AAA is increasing. This is also the case for patients with abdominal aortic aneurysm rupture. Age must not be the reason of a treatment refusal. Optimal therapeutic option ought to be found. The following article is based on literature analysis including current guidelines but also on my Clinics significant experience. Furthermore, this article show cases options for vascular medicine in undeveloped countries that can not apply endovascular procedures at a sufficient level and to a sufficient extent. At this moment the following is evident. Thirty-day-mortality after repair of ruptured abdominal aortic aneurysms is significantly lower in high-volume hospitals. Due to different reasons all ruptured abdominal aortic aneurysms are not suitable for EVAR. Open repair of ruptured abdominal aortic aneurysm should be performed by experienced open vascular surgeons. This could also be said for the treatment of endovascular complications that require open surgical conversion. There is no ideal procedure for the treatment of AAA. Each has its own advantages and disadvantages, its own limits and complications, as well as indications and contraindications. Future reductions in mortality of ruptured abdominal aortic aneurysms will depend on implementation of population-based screening; on strategies to prevent postoperative organ injury and also on new medical technology

  4. [Modern aortic surgery in Marfan syndrome--2011].

    Science.gov (United States)

    Kallenbach, K; Schwill, S; Karck, M

    2011-09-01

    Marfan syndrome is a hereditary disease with a prevalence of 2-3 in 10,000 births, leading to a fibrillin connective tissue disorder with manifestations in the skeleton, eye, skin, dura mater and in particular the cardiovascular system. Since other syndromes demonstrate similar vascular manifestations, but therapy may differ significantly, diagnosis should be established using the revised Ghent nosology in combination with genotypic analysis in specialized Marfan centres. The formation of aortic root aneurysms with the subsequent risk of acute aortic dissection type A (AADA) or aortic rupture limits life expectancy in patients with Marfan syndrome. Therefore, prophylactic replacement of the aortic root needs to be performed before the catastrophic event of AADA can occur. The goal of surgery is the complete resection of pathological aortic tissue. This can be achieved with excellent results by using a (mechanically) valved conduit that replaces both the aortic valve and the aortic root (Bentall operation). However, the need for lifelong anticoagulation with Coumadin can be avoided using the aortic valve sparing reimplantation technique according to David. The long-term durability of the reconstructed valve is favourable, and further technical improvements may improve longevity. Although results of prospective randomised long-term studies comparing surgical techniques are lacking, the David operation has become the surgical method of choice for aortic root aneurysms, not only at the Heidelberg Marfan Centre. Replacement of the aneurysmal dilated aortic arch is performed under moderate hypothermic circulatory arrest combined with antegrade cerebral perfusion using a heart-lung machine, which we also use in thoracic or thoracoabdominal aneurysms. Close post-operative follow-up in a Marfan centre is pivotal for the early detection of pathological changes on the diseased aorta.

  5. Stunning and Right Ventricular Dysfunction Is Induced by Coronary Balloon Occlusion and Rapid Pacing in Humans: Insights From Right Ventricular Conductance Catheter Studies.

    Science.gov (United States)

    Axell, Richard G; Giblett, Joel P; White, Paul A; Klein, Andrew; Hampton-Til, James; O'Sullivan, Michael; Braganza, Denise; Davies, William R; West, Nick E J; Densem, Cameron G; Hoole, Stephen P

    2017-06-06

    We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  6. MR imaging of aortic coarctation

    International Nuclear Information System (INIS)

    Beslic, S.

    2004-01-01

    Purpose. The purpose of this paper is to analyse the contribution of MRI as diagnostic procedure in the preoperative diagnosis of aortic coarctation (CoA), in patients with clinical and echocardiographic suspicion for this disease. Patients and methods. During the period of three years, eight patients were examined, 5 (62.5%) male and 3 (37.5%) female patients with clinical echocardiographic suspicion of CoA. The ratio between male and female patients was 1.7 : 1. The youngest patient was 3 and the oldest 46 years (median age was 15 years). Without administration of contrast media and using body coil the examinations were performed with MR machine Magnetom 1.0 Tesla ( S iemens ) , with the slice thickness of 6 mm, Fast spin-echo (FSE) T1W sequences, Cine gradient echo (GRE) sequence with slab 7 mm and time of flight (TOF) sequence with MIP reconstructions were applied. During the examinations the patients underwent also ECG gating. Examinations were done in axial, coronal and oblique sagittal projections with measuring of the dimensions of cardiovascular structures. Results. CoA was found in 8 (100%) patients. In 7 (87.5%) cases, coarctation developed at isthmus and in one case, coarctation was detected at the horizontal part of aortic arch, between the truncus arteriosus of the left carotid communis artery. Aortal insufficiency was found in 7 (87.5%) patients; in four of them (50%), bicuspidia was confirmed (bicuspid aortic valve), 7 (87.5%) patients had slightly expressed hypertrophy of the left ventricle. Two (25%) patients had dilatation of the ascendant aorta, six (75%) wider outgoing vessels of the aortic arch, four (50%) had well developed arterial collaterals and 2 (25%) patients rib notching. In 2 (25%) patients as side finding thymus persistent was found. Average diameter of coarctation was 10 mm. In one patient, CoA was accompanied with stenosis of pulmonary artery, in one with ventricular septal defect, and one with tricuspid insufficiency. The results

  7. The Balloon-Based Manometry Evaluation of Swallowing in Patients with Amyotrophic Lateral Sclerosis

    Directory of Open Access Journals (Sweden)

    Jerzy Tomik

    2017-03-01

    Full Text Available The aim of the study was to analyse the disturbances of the oro-pharyngeal swallowing phase of dysphagia in amyotrophic lateral sclerosis (ALS patients with the use of specific manometric measurements and to evaluate their plausible association with the duration of the disease. Seventeen patients with ALS were evaluated with manometric examinations of the oral and pharyngeal part of the gastrointestinal tract. Tests were carried out by using the oesophageal balloon-based method with four balloon transducers located 5 cm away from each other. The following manometric parameters were analysed: the base of tongue contraction (BTC and the upper oesophageal sphincter pressure (UESP, and the hypopharyngeal suction pump (HSP as well as the oro-pharyngeal, pharyngeal and hypopharyngeal transit time and average pharyngeal bolus velocity (oropharyngeal transit time (OTT, pharyngeal transit time (PTT, hypopharyngeal transit time (HTT and average pharyngeal bolus velocity (APBV, respectively. Manomatric examinations during swallowing in patients with ALS showed significant weakness of BTC, a decrease of HSP and a decrease of the velocity of bolus transit inside the pharynx which were particularly marked between the first and the third examination. Manometric examinations of the oro-pharyngeal part of the gastrointestinal tract are useful and supportive methods in the analysis of swallowing disturbances in ALS patients.

  8. Normetex Pump Alternatives Study

    International Nuclear Information System (INIS)

    Clark, Elliot A.

    2013-01-01

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying

  9. Heart failure - surgeries and devices

    Science.gov (United States)

    ... surgery; HF - surgery; Intra-aortic balloon pumps - heart failure; IABP - heart failure; Catheter based assist devices - heart failure ... problem may cause heart failure or make heart failure worse. Heart valve surgery may be needed to repair or ...

  10. Circulation pump mounting

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    The suspension is described of nuclear reactor circulating pumps enabling their dilatation with a minimum reverse force consisting of spacing rods supported with one end in the anchor joints and provided with springs and screw joints engaging the circulating pump shoes. The spacing rods are equipped with side vibration dampers anchored in the shaft side wall and on the body of the circulating pump drive body. The negative reverse force F of the spacing rods is given by the relation F=Q/l.y, where Q is the weight of the circulating pump, l is the spatial distance between the shoe joints and anchor joints, and y is the deflection of the circulating pump vertical axis from the mean equilibrium position. The described suspension is advantageous in that that the reverse force for the deflection from the mean equilibrium position is minimal, dynamic behaviour is better, and construction costs are lower compared to suspension design used so far. (J.B.)

  11. Imaging techniques in aortic valve and root surgery

    NARCIS (Netherlands)

    Regeer, M.V.

    2017-01-01

    Aortic valve sparing surgery for aortic regurgitation and/or aortopathy serves as an alternative to aortic valve and root replacement. One of the advantages of aortic valve sparing surgery over conventional replacement is that there is no need for life-long anticoagulation, which is particularly

  12. Detecting Seismic Infrasound Signals on Balloon Platforms

    Science.gov (United States)

    Krishnamoorthy, S.; Komjathy, A.; Cutts, J. A.; Pauken, M.; Garcia, R.; Mimoun, D.; Jackson, J. M.; Kedar, S.; Smrekar, S. E.; Hall, J. L.

    2017-12-01

    The determination of the interior structure of a planet requires detailed seismic investigations - a process that entails the detection and characterization of seismic waves due to geological activities (e.g., earthquakes, volcanoes, etc.). For decades, this task has primarily been performed on Earth by an ever-expanding network of terrestrial seismic stations. However, on planets such as Venus, where the surface pressure and temperature can reach as high as 90 atmospheres and 450 degrees Celsius respectively, placing seismometers on the planet's surface poses a vexing technological challenge. However, the upper layers of the Venusian atmosphere are more benign and capable of hosting geophysical payloads for longer mission lifetimes. In order to achieve the aim of performing geophysical experiments from an atmospheric platform, JPL and its partners (ISAE-SUPAERO and California Institute of Technology) are in the process of developing technologies for detection of infrasonic waves generated by earthquakes from a balloon. The coupling of seismic energy into the atmosphere critically depends on the density differential between the surface of the planet and the atmosphere. Therefore, the successful demonstration of this technique on Earth would provide ample reason to expect success on Venus, where the atmospheric impedance is approximately 60 times that of Earth. In this presentation, we will share results from the first set of Earth-based balloon experiments performed in Pahrump, Nevada in June 2017. These tests involved the generation of artificial sources of known intensity using a seismic hammer and their detection using a complex network of sensors, including highly sensitive micro-barometers suspended from balloons, GPS receivers, geophones, microphones, and seismometers. This experiment was the first of its kind and was successful in detecting infrasonic waves from the earthquakes generated by the seismic hammer. We will present the first comprehensive analysis

  13. Microcontroller uses in Long-Duration Ballooning

    Science.gov (United States)

    Jones, Joseph

    This paper discusses how microcontrollers are being utilized to fulfill the demands of long duration ballooning (LDB) and the advantages of doing so. The Columbia Scientific Balloon Facility (CSBF) offers the service of launching high altitude balloons (120k ft) which provide an over the horizon telemetry system and platform for scientific research payloads to collect data. CSBF has utilized microcontrollers to address multiple tasks and functions which were previously performed by more complex systems. A microcontroller system has been recently developed and programmed in house to replace our previous backup navigation system which is used on all LDB flights. A similar microcontroller system was developed to be independently launched in Antarctica before the actual scientific payload. This system's function is to transmit its GPS position and a small housekeeping packet so that we can confirm the upper level float winds are as predicted from satellite derived models. Microcontrollers have also been used to create test equipment to functionally check out the flight hardware used in our telemetry systems. One test system which was developed can be used to quickly determine if our communication link we are providing for the science payloads is functioning properly. Another system was developed to provide us with the ability to easily determine the status of one of our over the horizon communication links through a closed loop system. This test system has given us the capability to provide more field support to science groups than we were able to in years past. The trend of utilizing microcontrollers has taken place for a number of reasons. By using microcontrollers to fill these needs, it has given us the ability to quickly design and implement systems which meet flight critical needs, as well as perform many of the everyday tasks in LDB. This route has also allowed us to reduce the amount of time required for personnel to perform a number of the tasks required

  14. Correction of aortic insufficiency with an external adjustable prosthetic aortic ring.

    Science.gov (United States)

    Gogbashian, Andrew; Ghanta, Ravi K; Umakanthan, Ramanan; Rangaraj, Aravind T; Laurence, Rita G; Fox, John A; Cohn, Lawrence H; Chen, Frederick Y

    2007-09-01

    Less invasive, valve-sparing options are needed for patients with aortic insufficiency (AI). We sought to evaluate the feasibility of reducing AI with an external adjustable aortic ring in an ovine model. To create AI, five sheep underwent patch plasty enlargement of the aortic annulus and root by placement of a 10 x 15 mm pericardial patch between the right and noncoronary cusps. An adjustable external ring composed of a nylon band was fabricated and placed around the aortic root. Aortic flow, aortic pressure, and left ventricular pressures were measured with the ring loose (off) and tightened (on). Mean regurgitant orifice area decreased by 86%, from 0.07 +/- 0.03 cm2 (ring loose, off) to 0.01 +/- 0.00 cm2 (ring tightened, on) [p < 0.01]. The regurgitant fraction decreased from 18 +/- 4% to 2 +/- 1% [p < 0.01]. The ring did not significantly affect stroke volume and aortic pressure. An ovine model of aortic root dilatation resulting in acute AI has been developed. In this model, application of an external, adjustable constricting aortic ring eliminated AI. An aortic ring may be a useful adjunct in reducing AI secondary to annular dilatation.

  15. BWR series pump recirculation system

    International Nuclear Information System (INIS)

    Dillmann, C.W.

    1992-01-01

    This patent describes a recirculation system for driving reactor coolant water contained in an annular downcomer defined between a boiling water reactor vessel and a reactor core spaced radially inwardly therefrom. It comprises a plurality of circumferentially spaced second pumps disposed in the downcomer, each including an inlet for receiving from the downcomer a portion of the coolant water as pump inlet flow, and an outlet for discharging the pump inlet flow pressurized in the second pump as pump outlet flow; and means for increasing pressure of the pump inlet flow at the pump inlet including a first pump disposed in series flow with the second pump for first receiving the pump inlet flow from the downcomer and discharging to the second pump inlet flow pressurized in the first pump

  16. High pressure liquid gas pump

    Science.gov (United States)

    Acres, R. L.

    1972-01-01

    Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.

  17. The use of transcatheter aortic valve replacement vs surgical aortic valve replacement for the treatment of aortic stenosis

    Directory of Open Access Journals (Sweden)

    Jensen HA

    2015-08-01

    Full Text Available Hanna A Jensen, Lillian L Tsai, Vinod H Thourani Division of Cardiothoracic Surgery, Joseph B Whitehead Department of Surgery, Structural Heart and Valve Center, Emory University School of Medicine, Atlanta, GA, USA Abstract: Severe aortic stenosis (AS is associated with considerable morbidity and mortality and is increasing in prevalence as the global population increases. Since AS primarily affects the elderly, many of these patients have comorbidities that make them poor candidates for the gold standard treatment for AS, surgical aortic valve replacement. Transcatheter aortic valve replacement has emerged as a novel technology for the management of AS in higher risk patients over the past decade. Randomized trials have established the safety and efficacy of transcatheter aortic valve replacement, and the medical community has rallied to identify the patients who are most suitable for this transformative treatment. This review focuses on outlining the key procedural differences, describing the unique challenges of both operations, and finally assessing and comparing outcomes both on a general level and in challenging patient subgroups. Keywords: aortic valve replacement, transcatheter aortic valve replacement, surgical aortic valve replacement 

  18. Aortic root surgery in Marfan syndrome: Comparison of aortic valve-sparing reimplantation versus composite grafting.

    Science.gov (United States)

    Karck, Matthias; Kallenbach, Klaus; Hagl, Christian; Rhein, Christine; Leyh, Rainer; Haverich, Axel

    2004-02-01

    The objective of this study was to compare the results of aortic valve-sparing reimplantation and aortic root replacement with mechanical valve conduits in patients with Marfan syndrome undergoing operation for aortic root aneurysms. Patients and methods Between March 1979 and April 2002, 119 patients with clinical evidence of Marfan syndrome underwent composite graft replacement with mechanical valve conduits (n = 74) or aortic valve-sparing reimplantation according to David (n = 45). The underlying causes were aortic dissection type A (43 patients) and aneurysms (76 patients). Patients undergoing aortic valve reimplantation were younger compared with patients undergoing composite grafting (28 vs 35 years, P =.002) and had longer intraoperative aortic crossclamp times (125 vs 78 minutes, P valve reimplantation (P =.15). Mean follow-up was 30 months for patients undergoing aortic valve reimplantation and 114 months for patients undergoing composite grafting. Freedom from reoperation and death after 5 years postoperatively was 92% and 89% in patients undergoing composite grafting and 84% and 96% in patients undergoing aortic valve reimplantation (P =.31; P =.54), respectively. Thromboembolic complications or late postoperative bleeding occurred in 17 patients undergoing composite grafting, and an early postoperative event occurred in 1 patient undergoing aortic valve reimplantation. The results of aortic valve reimplantation and composite grafting of the aortic valve and ascending aorta with mechanical valve conduits are similar with regard to early and mid-term postoperative mortality and to the incidence of late reoperations in patients with Marfan syndrome. The low risk of thromboembolic or bleeding complications favors aortic valve reimplantation in these patients.

  19. The role of elastomeric pumps in postoperative analgesia in orthopaedics and factors affecting their flow rate.

    Science.gov (United States)

    Theodorides, Anthony Andreas

    2017-12-01

    Elastomeric pumps are mechanical devices composed of an elastomeric balloon reservoir into which the drug to be infused is stored, a protective casing (used by some manufacturers), a flow controller and a wound catheter. In orthopaedics they are used to provide continuous local infiltration analgesia. In this way patients rely less on other routes of analgesia and thus avoid their systemic side effects. Studies have shown good response to analgesia with these pumps for the first 24 hours but their benefit is not as clear at 48 and 72 hours. There are numerous factors that affect the flow rate of elastomeric pumps. Some are inherent to all elastomeric pumps such as: the pressure exerted by the elastomeric balloon, catheter size, the vertical height of the pump in relation to the wound, viscosity and partial filling. There are also other factors which vary according to the manufacturer such as: the optimal temperature to obtain the desired flow rate as this directly affects viscosity, the dialysate that the analgesic drug is mixed with (ie normal saline or 5% dextrose), and the storage conditions of the fluid to be infused. It is thus essential to follow the clinical guidelines provided by the manufacturer in order to obtain the desired flow rate. Copyright the Association for Perioperative Practice.

  20. Boston's balloon dilatation for treatment of cardiac achalasia

    International Nuclear Information System (INIS)

    Yin Jianguo; Song Jinwen; Yang Yan; Liu Xiaohong; Fu Zhiming; Zhang Yaqin

    2001-01-01

    Objective: To review and summarize effectiveness and method of the Boston's balloon dilation in cardiac achalasia. Methods: The intensified guide wire was inserted into stomach through mouth cavity under TV control. The Boston's balloon was inserted to the cardiac stricture through the guide wire and dilatated with 15% contrast medium with to a maximum diameter for five minutes and then the balloon was dilatated again for 3-5 minutes, all together for 3-4 times. The severe stricture must be pre-dilatated with 20-25 mm diameter balloon. Results: The balloon insertion was technically successful in all 26 patients. The once success of balloon dilation was achieved in 24 patients and twice in other 2. Follow-up time was from 2 weeks to 31 months (mean 10.6 months). Recurrent stenosis had not occurred in all patients. Remission rate of dysphagia was 100%. Esophageal reflux occurred in 3 patients. Conclusions: The Boston's balloon dilatation is simple and effective for treatment of cardiac achalasia. The method sometimes may replace surgical procedure

  1. Rectal Balloon for the Immobilization of the Prostate Internal Motion

    International Nuclear Information System (INIS)

    Lee, Sang Kyu; Beak, Jong Geal; Kim, Joo Ho; Jeon, Byong Chul; Cho, Jeong Hee; Kim, Dong Wook; Song, Tae Soo; Cho, Jae Ho; Na, Soo Kyong

    2005-01-01

    The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning same repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal balloon position and verified the isodose distribution of rectum wall at closed prostate. Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficient for treated prostate cancer patients.

  2. Ballooning modes or Fourier modes in a toroidal plasma?

    International Nuclear Information System (INIS)

    Connor, J.W.; Taylor, J.B.

    1987-01-01

    The relationship between two different descriptions of eigenmodes in a torus is investigated. In one the eigenmodes are similar to Fourier modes in a cylinder and are highly localized near a particular rational surface. In the other they are the so-called ballooning modes that extend over many rational surfaces. Using a model that represents both drift waves and resistive interchanges the transition from one of these structures to the other is investigated. In this simplified model the transition depends on a single parameter which embodies the competition between toroidal coupling of Fourier modes (which enhances ballooning) and variation in frequency of Fourier modes from one rational surface to another (which diminishes ballooning). As the coupling is increased each Fourier mode acquires a sideband on an adjacent rational surface and these sidebands then expand across the radius to form the extended mode described by the conventional ballooning mode approximation. This analysis shows that the ballooning approximation is appropriate for drift waves in a tokamak but not for resistive interchanges in a pinch. In the latter the conventional ballooning effect is negligible but they may nevertheless show a ballooning feature. This is localized near the same rational surface as the primary Fourier mode and so does not lead to a radially extended structure

  3. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    International Nuclear Information System (INIS)

    Chen, I-Ming; Chen, Po-Lin; Huang, Chun-Yang; Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che

    2017-01-01

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  4. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, I-Ming [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China); Chen, Po-Lin; Huang, Chun-Yang [National Yang Ming University, Department of Medicine, School of Medicine (China); Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che, E-mail: ccshih@vghtpe.gov.tw [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China)

    2017-05-15

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  5. Ballooning modes on open magnetic field lines

    International Nuclear Information System (INIS)

    Hameiri, E.

    1999-01-01

    The ballooning instability on open magnetic field lines is given a thorough mathematical analysis. It is shown that resistive bounding ends (endplates) induce the same stability properties as insulating ends. When unstable, the maximal growth rate increases monotonically with boundary resistivity. An interchange instability may be present, and one necessary condition for its stability is that ∫dl/B be constant on pressure surfaces. (This is an equilibrium existence condition for systems with closed magnetic field lines.) Another necessary condition for interchange stability has the same form as in the closed line case. Precise necessary and sufficient stability criteria are given for various types of bounding ends, including insulating, resistive, and perfectly conducting. copyright 1999 American Institute of Physics

  6. Balloon-tipped flow-directed catheters

    International Nuclear Information System (INIS)

    Ganz, P.; Swan, H.J.C.; Ganz, W.

    1986-01-01

    Diagnostic catheterization of the right side of the heart with semirigid cardiac catheters requires fluoroscopic guidance and substantial skill. Abnormal positions of the heart chambers and of the great vessels associated with cardiac dilatation or with congenital malformation present difficulties even to experienced laboratory cardiologists. These problems have been largely overcome by the introduction of balloon tipped flow directed catheters, which allow for rapid and relatively safe catheterization of the pulmonary artery without fluoroscopy. It was through the application of these catheters in the intensive care unit that the many pitfalls in the clinical assessment of hemodynamic disturbances became apparent. Although S3 gallop sounds may be useful in the clinical recognition of chronic ventricular failure, their presence or absence has limited predictive value in estimating left ventricular filling pressure in myocardial infarction. Information derived from right heart catheterization is often pivotal in the evaluation of hemodynamic disorders, in directing treatment, and in monitoring the results of therapy in critically ill patients

  7. Ballooning instabilities in toroidally linked mirror systems

    International Nuclear Information System (INIS)

    Hastie, R.J.; Watson, C.J.H.

    1977-01-01

    This paper examines the stability against ballooning modes of plasma equilibria in toroidally linked mirror configurations consisting of a number of quadrupole minimum-B mirrors linked toroidally. On the basis of the Kruskal-Oberman energy principle, a class of displacements is identified which are potentially unstable, and a necessary criterion for stability is derived. The criterion is obtained from the eigenvalues of an ordinary differential equation, which determines the variation of the displacement along a field line. The coefficients in the equation are determined by the configuration, and by inserting various model configurations, estimates are obtained of the maximum value of β consistent with stability. In cases of interest, quite high β-values are obtained. (author)

  8. N-dependence of ballooning instabilities

    International Nuclear Information System (INIS)

    Dewar, R.L.; Manickam, J.; Grimm, R.C.; Chance, M.S.

    1980-05-01

    The critical β for stability against ideal hydromagnetic internal ballooning modes as a function of toroidal mode number, n, is calculated for two different equilibrium sequences by use of a finite element technique (n less than or equal to 20), and a WKB formalism (n greater than or equal to 5). The agreement between the two methods is good in the overlap region 5 approx.less than or equal to n approx. less than or equal to 20. The WKB formula reduces to the 1/n correction at very high n, but is much more accurate at moderate n. The critical β vs n curves exhibit oscillatory structure at low n, but in both sequences the lower bound on β/sub c/ approx. 5%. For reactor parameters, finite Larmor radius effects are not expected to have a large effect on this β-limitation

  9. Percutaneous balloon dilatation for transplant ureteral strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Chul [Chungnam National University School of Medicine, Taechun (Korea, Republic of); Banner, Marc P [University of Pennsylvania School of Medicine, Philadelphia (United States)

    1993-09-15

    We report 10 kidney allografted patients treated for 11 ureteral strictures with standard endourlogic balloon catheter dilatation and internal stenting between August 1979 and December 1991. They have been followed until 2 to 140 months (mean 42). We compared and analyzed the 6 successful strictures (54%) and 5 unsuccessful strictures. There was no statistically significant difference of demographic, clinical and radiologic interventional techniques between two groups. But there was slightly higher success rate in abruptly narrowed shorter fibrotic strictures in ureteroneocystomy sites than smoothly taped longer ones in other sites of the ureter. Longterm stenting by the transplantation team with cystoscopic removal of internal ureteral stents by urologists resulted in 3 cases of stent occlusion, encrustation or fracture. Exact early diagnosis of ureteral stricture with continued close follow up and proper radiologic interventional procedure with optimal stenting period may increase the success rate and still provide an alternative to surgery.

  10. High Energy Antimatter Telescope (HEAT) Balloon Experiment

    Science.gov (United States)

    Beatty, J. J.

    1995-01-01

    This grant supported our work on the High Energy Antimatter Telescope(HEAT) balloon experiment. The HEAT payload is designed to perform a series of experiments focusing on the cosmic ray positron, electron, and antiprotons. Thus far two flights of the HEAT -e+/- configuration have taken place. During the period of this grant major accomplishments included the following: (1) Publication of the first results of the 1994 HEAT-e+/- flight in Physical Review Letters; (2) Successful reflight of the HEAT-e+/- payload from Lynn Lake in August 1995; (3) Repair and refurbishment of the elements of the HEAT payload damaged during the landing following the 1995 flight; and (4) Upgrade of the ground support equipment for future flights of the HEAT payload.

  11. Extending the golden hour: Partial resuscitative endovascular balloon occlusion of the aorta in a highly lethal swine liver injury model.

    Science.gov (United States)

    Russo, Rachel M; Williams, Timothy K; Grayson, John Kevin; Lamb, Christopher M; Cannon, Jeremy W; Clement, Nathan F; Galante, Joseph M; Neff, Lucas P

    2016-03-01

    Combat-injured patients may require rapid and sustained support during transport; however, the prolonged aortic occlusion produced by conventional resuscitative endovascular balloon occlusion of the aorta (REBOA) may lead to substantial morbidity. Partial REBOA (P-REBOA) may permit longer periods of occlusion by allowing some degree of distal perfusion. However, the ability of this procedure to limit exsanguination is unclear. We evaluated the impact of P-REBOA on immediate survival and ongoing hemorrhage in a highly lethal swine liver injury model. Fifteen Yorkshire-cross swine were anesthetized, instrumented, splenectomized, and subjected to rapid 10% total blood loss followed by 30% liver amputation. Coagulopathy was created through colloid hemodilution. Randomized swine received no intervention (control), P-REBOA, or complete REBOA (C-REBOA). Central mean arterial pressure (cMAP), carotid blood flow, and blood loss were recorded. Balloons remained inflated in the P-REBOA and C-REBOA groups for 90 minutes followed by graded deflation. The study ended at 180 minutes from onset of hemorrhage or death of the animal. Survival analysis was performed, and data were analyzed using repeated-measures analysis of variance with post hoc pairwise comparisons. Mean survival times in the control, P-REBOA, and C-REBOA groups were, 25 ± 21, 86 ± 40, and 163 ± 20 minutes, respectively (p golden hour while maintaining cMAP and carotid flow at physiologic levels.

  12. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  13. Imaging of thoracic aortic dissection

    International Nuclear Information System (INIS)

    Vu, F.H.; Young, N.; Soo, Y.S.

    1994-01-01

    Acute thoracic aortic dissection has a high mortality rate if untreated, so the diagnosis must be rapidly made. Multiple imaging techniques are often used. This retrospective study from 1988 to 1993 assesses the usefulness in diagnosis of chest X-rays, computed tomography (CT) scanning, aortography, magnetic resonance imaging (MRI), trans-thoracic (TTE) and trans-oesophageal (TOE) echocardiography. Forty-two patients with a final clinical diagnosis of dissection were studied. The diagnosis was confirmed in 16 (13 at surgery and three at autopsy). Three died with dissection given as the only cause of death. Chest X-ray abnormalities were seen in all 19 patients with surgery or death from dissection, with a widened mediastinum and/or dilated aorta being present in 17. In the group of 16 patients with surgery or autopsy proof, CT scans found dissections in 9 out of 12 patients studied and correctly classified the type in only five. Aortography was preformed in five, with accurate depiction of dissection and type in all. TTE found dissections in three of eight patients imaged by this method. MRI and TOE were preformed each on two patients, with accurate depiction of dissection and type in each. Because of the relatively low sensitivity of CT scanning in defining aortic dissections Westmead Hospital is currently assessing the use of TOE as the prime imaging modality prior to surgical intervention. 17 refs., 4 tabs., 4 figs

  14. Spontaneous perforation of a syphilitic aneurysm of the aortic arch into the pulmonary artery

    International Nuclear Information System (INIS)

    Stampfel, G.

    1983-01-01

    An aortopulmonary fistula in case of a bag-shaped aneurysm of the aortic arch is demonstrated via angiography. A diagnosis to the effect that the existence of this phenomenon is suspected, can already be arrived at when examining the plain radiography of the thorax. We can say that a sign of an aortopulmonary fistula is represented, in case of an aneurysm of the aorta ascendens and of the arcus aortae, by the existence of a left-right shunt with hypercirculation in the pulmonary circulation, in most cases also signs of right ventricular insufficiency. This is often combined with a typical previous history of sudden dyspnoeas and thoracic pain. The article points out the theoretical possibility of balloon catheter occlusion of the fistula to relieve the acute right ventricular load. (orig.) [de

  15. Percutaneous closure of a large aortic paravalvular leak using two duct occluder devices

    Directory of Open Access Journals (Sweden)

    Navaneetha Sasikumar

    2013-05-01

    Full Text Available A 21-year-old male presented with severe aortic paravalvular leak. He had undergone three cardiac surgeries and also had chronic kidney disease. It was decided for a trans-catheter closure owing to the risks of a fourth surgery and co-morbidity. The device was sized based on angiogram, balloon sizing and two dimensional transesophageal echo. There was significant residual leak after deployment of first device. Hence the defect was re-crossed and two duct occluder devices were positioned across the leak from two arterial access. After confirming position and satisfactory reduction in paravalvular leak, the devices were released in tandem. There was near abolition of leak. The patient is asymptomatic at three months follow up. Larger paravalvular leaks are better addressed with two devices of smaller size rather than a single large device. Technical considerations while deploying multiple devices are discussed.

  16. Angiographic assessment of initial balloon angioplasty results.

    Science.gov (United States)

    Gardiner, Geoffrey A; Sullivan, Kevin L; Halpern, Ethan J; Parker, Laurence; Beck, Margaret; Bonn, Joseph; Levin, David C

    2004-10-01

    To determine the influence of three factors involved in the angiographic assessment of balloon angioplasty-interobserver variability, operator bias, and the definition used to determine success-on the primary (technical) results of angioplasty in the peripheral arteries. Percent stenosis in 107 lesions in lower-extremity arteries was graded by three independent, experienced vascular radiologists ("observers") before and after balloon angioplasty and their estimates were compared with the initial interpretations reported by the physician performing the procedure ("operator") and an automated quantitative computer analysis. Observer variability was measured with use of intraclass correlation coefficients and SD. Differences among the operator, observers, and the computer were analyzed with use of the Wilcoxon signed-rank test and analysis of variance. For each evaluator, the results in this series of lesions were interpreted with three different definitions of success. Estimation of residual stenosis varied by an average range of 22.76% with an average SD of 8.99. The intraclass correlation coefficients averaged 0.59 for residual stenosis after angioplasty for the three observers but decreased to 0.36 when the operator was included as the fourth evaluator. There was good to very good agreement among the three independent observers and the computer, but poor correlation with the operator (P definition of success was used. Significant differences among the operator, the three observers, and the computer were not present when the definition of success was based on less than 50% residual stenosis. Observer variability and bias in the subjective evaluation of peripheral angioplasty can have a significant influence on the reported initial success rates. This effect can be largely eliminated with the use of residual stenosis of less than 50% to define success. Otherwise, meaningful evaluation of angioplasty results will require independent panels of evaluators or

  17. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  18. Endoluminal Treatment of Ruptured Abdominal Aortic Aneurysm with Small Intestinal Submucosa Sandwich Endografts: A Pilot Study in Sheep

    International Nuclear Information System (INIS)

    Yamada, Katsuyuki; Pavcnik, Dusan; Uchida, Barry T.; Timmermans, Hans A.; Corless, Christopher L.; Yin, Qiang; Yamakado, Koichiro; Wha Park, Joong; Roesch, Josef; Keller, Frederick S.; Sato, Morio; Yamada, Ryusaku

    2001-01-01

    Purpose: To evaluate efficacy of small intestinal submucosa (SIS) Sandwich endografts for the treatment of acute rupture of abdominal aortic aneurysms (AAA) and to explore the short-term reaction of the aorta to this material.Methods: In eight adult sheep, an infrarenal AAA was created transluminally by dilation of a short Palmaz stent. In six sheep, the aneurysm was then ruptured by overdilation of the stent with a large angioplasty balloon. Two sheep with AAAs that were not ruptured served as controls. A SIS Sandwich endograft, consisting of a Z stent frame with 5 bodies and covered inside and out with SIS, was used to exclude the ruptured and non-ruptured AAAs. Follow-up aortography was done immediately after the procedure and before sacrifice at 4, 8, or 12 weeks. Autopsy and histologic studies followed.Results: Endograft placement was successful in all eight sheep. Both ruptured and non-ruptured AAAs were successfully excluded. Three animals with AAA rupture developed hind leg paralysis due to compromise of the arterial supply to the lower spinal cord and were sacrificed 1 day after the procedure. In five animals, three with rupture and two controls, follow-up aortograms revealed no aortic stenoses and no perigraft leaks. Gross and histologic studies revealed incorporation of the endografts into the aortic wall with replacement of SIS by dense neointima that was completely endothelialized in areas where the endograft was in direct contact with the aortic wall. In central portions of the endograft, in contact with the thrombosed aneurysm, endothelialization was incomplete even at 12 weeks.Conclusion: The SIS Sandwich endografts effectively excluded simple AAAs and ruptured AAAs. They were rapidly incorporated into the aortic wall. A detailed long-term study is warranted

  19. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  20. An investigation of electrostatically deposited radionuclides on latex balloons

    International Nuclear Information System (INIS)

    Price, T.; Caly, A.

    2012-01-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  1. Analysis of Flight of Near-Space Balloon

    Science.gov (United States)

    Miller, Zech; Evans, Austin; Seyfert, James; Leadlove, Kyle; Gumina, Kaitlyn; Martell, Eric

    2015-04-01

    In December 2014, the Electronics class at Millikin University launched a balloon designed to travel into the near-space region of the atmosphere. The balloon was equipped with an instrumentation package including a camera, accelerometer, barometric pressure sensor, temperature probes, as well as a system for tracking using an Automatic Packet Reporting System (APRS). The balloon was launched from Decatur, IL, and landed in Marysville, OH, nearly 320 miles away. The students then analyzed the data from the flight and compared results to expectations.

  2. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    Pretolesi, F.; Derchi, L.E.; Redaelli, G.; Papagni, L.

    2001-01-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  3. An investigation of electrostatically deposited radionuclides on latex balloons

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.; Caly, A., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2012-07-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  4. Balloon dilation of congenital supravalvular pulmonic stenosis in a dog.

    Science.gov (United States)

    Treseder, Julia R; Jung, SeungWoo

    2017-03-30

    Percutaneous balloon valvuloplasty is considered the standard of care for treatment of valvular pulmonic stenosis, a common congenital defect in dogs. Supravalvular pulmonic stenosis is a rare form of pulmonic stenosis in dogs and standard treatment has not been established. Although, there have been reports of successful treatment of supravalvular pulmonic stenosis with surgical and stenting techniques, there have been no reports of balloon dilation to treat dogs with this condition. Here, a case of supravalvular pulmonic stenosis diagnosed echocardiographically and angiographically in which a significant reduction in pressure gradient was achieved with balloon dilation alone is presented.

  5. Ascending aortic injuries following blunt trauma.

    Science.gov (United States)

    Sun, Xiumei; Hong, Jenny; Lowery, Robert; Goldstein, Steven; Wang, Zuyue; Lindsay, Joseph; Hill, Peter C; Corso, Paul J

    2013-11-01

    The diagnosis and the management of traumatic thoracic aortic injuries have undergone significant changes due to new technology and improved prehospital care. Most of the discussions have focused on descending aortic injuries. In this review, we discuss the recent management of ascending aortic injuries. We found 5 cohort studies on traumatic aortic injuries and 11 case reports describing ascending aortic injuries between 1998 to the present through Medline research. Among case reports, 78.9% of cases were caused by motor vehicle accidents (MVA). 42.1% of patients underwent emergent open repair and the operative mortality was 12.5%. 36.8% underwent delayed repair. Associated injuries occurred in 84.2% of patients. Aortic valve injury was concurrent in 26.3% of patients. The incidence of ascending aortic injury ranged 1.9-20% in cohort studies. Traumatic injuries to the ascending aorta are relatively uncommon among survivors following blunt trauma. Aortography has been replaced by computed tomography and echocardiography as a diagnostic tool. Open repair, either emergent or delayed, remains the treatment of choice. © 2013 Wiley Periodicals, Inc.

  6. Aortic stenosis and vascular calcifications in alkaptonuria.

    Science.gov (United States)

    Hannoush, Hwaida; Introne, Wendy J; Chen, Marcus Y; Lee, Sook-Jin; O'Brien, Kevin; Suwannarat, Pim; Kayser, Michael A; Gahl, William A; Sachdev, Vandana

    2012-02-01

    Alkaptonuria is a rare metabolic disorder of tyrosine catabolism in which homogentisic acid (HGA) accumulates and is deposited throughout the spine, large joints, cardiovascular system, and various tissues throughout the body. In the cardiovascular system, pigment deposition has been described in the heart valves, endocardium, pericardium, aortic intima and coronary arteries. The prevalence of cardiovascular disease in patients with alkaptonuria varies in previous reports. We present a series of 76 consecutive adult patients with alkaptonuria who underwent transthoracic echocardiography between 2000 and 2009. A subgroup of 40 patients enrolled in a treatment study underwent non-contrast CT scans and these were assessed for vascular calcifications. Six of the 76 patients had aortic valve replacement. In the remaining 70 patients, 12 patients had aortic sclerosis and 7 patients had aortic stenosis. Unlike degenerative aortic valve disease, we found no correlation with standard cardiac risk factors. There was a modest association between the severity of aortic valve disease and joint involvement, however, we saw no correlation with urine HGA levels. Vascular calcifications were seen in the coronaries, cardiac valves, aortic root, descending aorta and iliac arteries. These findings suggest an important role for echocardiographic screening of alkaptonuria patients to detect valvular heart disease and cardiac CT to detect coronary artery calcifications. Published by Elsevier Inc.

  7. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  8. Electromagnetic pump technology

    International Nuclear Information System (INIS)

    Prabhakar, R.

    1994-01-01

    Fast Breeder Reactors have an important role to play in our nuclear power programme. Liquid metal sodium is used as the coolant for removing fission heat generated in fast reactors and a distinctive physical property of sodium is its high electrical conductivity. This enables application of electromagnetic (EM) pumps, working on same principle as electric motors, for pumping liquid sodium. Due to its lower efficiency as compared to centrifugal pumps, use of EM pumps has been restricted to reactor auxiliary circuits and experimental facilities. As part of our efforts to manufacture fast reactor components indigenously, work on the development of two types of EM pumps namely flat linear induction pump (FLIP) and annular linear induction pump (ALIP) has been undertaken. Design procedures based on an equivalent circuit approach have been established and results from testing a 5.6 x 10E-3 Cum/s (20 Cum/h) FLIP in a sodium loop were used to validate the procedure. (author). 7 refs., 6 figs

  9. Aortic stenosis: From diagnosis to optimal treatment

    Directory of Open Access Journals (Sweden)

    Tavčiovski Dragan

    2008-01-01

    Full Text Available Aortic stenosis is the most frequent valvular heart disease. Aortic sclerosis is the first characteristic lesion of the cusps, which is considered today as the process similar to atherosclerosis. Progression of the disease is an active process leading to forming of bone matrix and heavily calcified stiff cusps by inflammatory cells and osteopontin. It is a chronic, progressive disease which can remain asymptomatic for a long time even in the presence of severe aortic stenosis. Proper physical examination remains an essential diagnostic tool in aortic stenosis. Recognition of characteristic systolic murmur draws attention and guides further diagnosis in the right direction. Doppler echocardiography is an ideal tool to confirm diagnosis. It is well known that exercise tests help in stratification risk of asymptomatic aortic stenosis. Serial measurements of brain natriuretic peptide during a follow-up period may help to identify the optimal time for surgery. Heart catheterization is mostly restricted to preoperative evaluation of coronary arteries rather than to evaluation of the valve lesion itself. Currently, there is no ideal medical treatment for slowing down the disease progression. The first results about the effect of ACE inhibitors and statins in aortic sclerosis and stenosis are encouraging, but there is still not enough evidence. Onset symptoms based on current ACC/AHA/ESC recommendations are I class indication for aortic valve replacement. Aortic valve can be replaced with a biological or prosthetic valve. There is a possibility of percutaneous aortic valve implantation and transapical operation for patients that are contraindicated for standard cardiac surgery.

  10. Contemporary results of aortic valve repair for congenital disease: lessons for management and staged strategy.

    Science.gov (United States)

    Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor

    2017-09-01

    Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  12. Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns.

    Science.gov (United States)

    Schnell, Susanne; Smith, Danielle A; Barker, Alex J; Entezari, Pegah; Honarmand, Amir R; Carr, Maria L; Malaisrie, S Chris; McCarthy, Patrick M; Collins, Jeremy; Carr, James C; Markl, Michael

    2016-11-01

    Bicuspid aortic valve (BAV) is known to exhibit familial inheritance and is associated with aortopathy and altered aortic haemodynamics. However, it remains unclear whether BAV-related aortopathy can be inherited independently of valve morphology. Four-dimensional flow magnetic resonance imaging for the in vivo assessment of thoracic aortic 3D blood flow was performed in 24 BAV relatives with trileaflet aortic valves (age = 40 ± 14 years) and 15 healthy controls (age = 37 ± 10 years). Data analysis included aortic dimensions, shape (round/gothic/cubic), and 3D blood flow characteristics (semi-quantitative vortex/helix grading and peak velocities). Cubic and gothic aortic shapes were markedly more prevalent in BAV relatives compared with controls (38 vs. 7%). Ascending aorta (AAo) vortex flow in BAV relatives was significantly increased compared with controls (grading = 1.5 ± 1.0 vs. 0.6 ± 0.9, P = 0.015). Aortic haemodynamics were influenced by aortic shape: peak velocities were reduced for gothic aortas vs. round aortas (P = 0.003); vortex flow was increased for cubic aortas in the AAo (P gothic aortas in the AAo and descending aorta (P = 0.003, P = 0.029). Logistic regression demonstrated significant associations of shape with severity of vortex flow in AAo (P < 0.001) and aortic arch (P = 0.016) in BAV relatives. BAV relatives expressed altered aortic shape and increased vortex flow despite the absence of valvular disease or aortic dilatation. These data suggest a heritable component of BAV-related aortopathy affecting aortic shape and aberrant blood flow, independent of valve morphology. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  13. Combined Repair of Ascending Aortic Pseudoaneurysm and Abdominal Aortic Aneurysm in a Patient with Marfan Syndrome

    OpenAIRE

    Kokotsakis, John N.; Lioulias, Achilleas G.; Foroulis, Christophoros N.; Skouteli, Eleni Anna T.; Milonakis, Michael K.; Bastounis, Elias A.; Boulafendis, Dimitrios G.

    2003-01-01

    Pseudoaneurysms of the ascending aorta after the original inclusion/wrap technique of the Bentall procedure present a difficult surgical management problem and are associated with substantial morbidity and mortality. Patients with Marfan syndrome frequently develop aneurysms and dissections that involve multiple aortic segments. We present the case of a Marfan patient who successfully underwent repair of a giant ascending aortic pseudoaneurysm and concomitant repair of an abdominal aortic ane...

  14. The future of aortic surgery in Europe

    DEFF Research Database (Denmark)

    Czerny, Martin; Bachet, Jean; Bavaria, Joseph

    2012-01-01

    the interested reader with an overview of how aortic surgery and (perhaps more accurately) aortic medicine has evolved in Europe, and its present standing; also to provide a glimpse into the future, trying to disseminate the thoughts of a group of people actively involved in the development of aortic medicine......At least every ten years, each specialty should reflect upon its past, its present and its future, in order to be able to reconfirm the direction in which it is headed, to adopt suggestions from inside and outside and, consequently, to improve. As such, the aim of this manuscript is to provide...

  15. Mycotic Aneurysm of the Aortic Arch

    Directory of Open Access Journals (Sweden)

    Ji Hye Seo

    2014-08-01

    Full Text Available A mycotic aneurysm of the thoracic aorta is rare. We report a case of mycotic aneurysm that developed in the aortic arch. An 86-year-old man was admitted with fever and general weakness. Blood culture yielded methicillin-resistant Staphylococcus aureus. Chest X-ray showed an enlarged aortic arch, and computed tomography scan revealed an aneurysm in the aortic arch. The patient was treated only with antibiotics and not surgically. The size of the aneurysm increased rapidly, resulting in bronchial obstruction and superimposed pneumonia. The patient died of respiratory failure.

  16. Na,K-pump modulates intercellular communication in vascular wall

    DEFF Research Database (Denmark)

    Matchkov, Vladimir

    were used as a model for electrical coupling of SMCs by measuring membrane capacitance (Cm). SMCs were uncoupled (evaluated by inhibition of vasomotion and desynchronization of calcium transients in vascular wall, or by reduction to half of Cm measured in paired A7r5 cells) when the Na......  Ouabain, a specific inhibitor of the Na,K-pump, has previously been shown to interfere with intercellular communication. Here we test the hypothesis that the communication between vascular smooth muscle cells (SMCs) is regulated through an interaction between the Na,K-pump and the Na......,Ca-exchanger leading to an increase in the intracellular calcium concentration in discrete areas near the plasma membrane. The intracellular calcium concentration in individual SMCs was imaged in cultured rat aortic SMCs (A7r5) and simultaneously with isometric force in rat mesenteric small arteries. Paired A7r5 cells...

  17. Reverse extra-anatomic aortic arch debranching procedure allowing thoracic endovascular aortic repair of a chronic ascending aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ludovic Canaud, MD, PhD

    2018-06-01

    Full Text Available A 79-year-old woman was admitted with a large chronic dissecting ascending aortic aneurysm starting 5 mm distal to the ostia of the left coronary artery and ending immediately proximal to the innominate artery. A reverse extra-anatomic aortic arch debranching procedure was performed. During the same operative time, through a transapical approach, a thoracic stent graft was deployed with the proximal landing zone just distal to the coronary ostia and the distal landing zone excluding the origin of the left common carotid artery. The postoperative course was uneventful. Computed tomography at 12 months documented patent extra-anatomic aortic arch debranching and no evidence of endoleak. Keywords: Ascending aorta, Thoracic aorta, Aortic dissection, Stent graft

  18. The role of aortic wall CT attenuation measurements for the diagnosis of acute aortic syndromes

    International Nuclear Information System (INIS)

    Knollmann, Friedrich D.; Lacomis, Joan M.; Ocak, Iclal; Gleason, Thomas

    2013-01-01

    Objectives: To determine if measurements of aortic wall attenuation can improve the CT diagnosis of acute aortic syndromes. Methods: CT reports from a ten year period were searched for acute aortic syndromes (AAS). Studies with both an unenhanced and a contrast enhanced (CTA) series that had resulted in the diagnosis of intramural hematoma (IMH) were reviewed. Diagnoses were confirmed by medical records. The attenuation of aortic wall abnormalities was measured. The observed attenuation threshold was validated using studies from 39 new subjects with a variety of aortic conditions. Results: The term “aortic dissection” was identified in 1206, and IMH in 124 patients’ reports. IMH was confirmed in 31 patients, 21 of whom had both unenhanced and contrast enhanced images. All 21 had pathologic CTA findings, and no CTA with IMH was normal. Attenuation of the aortic wall was greater than 45 HUs on the CTA images in all patients with IMH. When this threshold was applied to the new group, sensitivity for diagnosing AAS was 100% (19/19), and specificity 94% (16/17). Addition of unenhanced images did not improve accuracy. Conclusions: Measurements of aortic wall attenuation in CTA have a high negative predictive value for the diagnosis of acute aortic syndromes

  19. Stroke Volume estimation using aortic pressure measurements and aortic cross sectional area: Proof of concept.

    Science.gov (United States)

    Kamoi, S; Pretty, C G; Chiew, Y S; Pironet, A; Davidson, S; Desaive, T; Shaw, G M; Chase, J G

    2015-08-01

    Accurate Stroke Volume (SV) monitoring is essential for patient with cardiovascular dysfunction patients. However, direct SV measurements are not clinically feasible due to the highly invasive nature of measurement devices. Current devices for indirect monitoring of SV are shown to be inaccurate during sudden hemodynamic changes. This paper presents a novel SV estimation using readily available aortic pressure measurements and aortic cross sectional area, using data from a porcine experiment where medical interventions such as fluid replacement, dobutamine infusions, and recruitment maneuvers induced SV changes in a pig with circulatory shock. Measurement of left ventricular volume, proximal aortic pressure, and descending aortic pressure waveforms were made simultaneously during the experiment. From measured data, proximal aortic pressure was separated into reservoir and excess pressures. Beat-to-beat aortic characteristic impedance values were calculated using both aortic pressure measurements and an estimate of the aortic cross sectional area. SV was estimated using the calculated aortic characteristic impedance and excess component of the proximal aorta. The median difference between directly measured SV and estimated SV was -1.4ml with 95% limit of agreement +/- 6.6ml. This method demonstrates that SV can be accurately captured beat-to-beat during sudden changes in hemodynamic state. This novel SV estimation could enable improved cardiac and circulatory treatment in the critical care environment by titrating treatment to the effect on SV.

  20. The role of aortic wall CT attenuation measurements for the diagnosis of acute aortic syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Knollmann, Friedrich D., E-mail: friedrich.knollmann@ucdmc.ucdavis.edu [Department of Radiology, University of California, Davis, 4860 Y Street, Sacramento, CA 95817 (United States); Departments of Radiology and Cardiothoracic Surgery, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA 15213 (United States); Lacomis, Joan M.; Ocak, Iclal; Gleason, Thomas [Department of Radiology, University of California, Davis, 4860 Y Street, Sacramento, CA 95817 (United States); Departments of Radiology and Cardiothoracic Surgery, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA 15213 (United States)

    2013-12-01

    Objectives: To determine if measurements of aortic wall attenuation can improve the CT diagnosis of acute aortic syndromes. Methods: CT reports from a ten year period were searched for acute aortic syndromes (AAS). Studies with both an unenhanced and a contrast enhanced (CTA) series that had resulted in the diagnosis of intramural hematoma (IMH) were reviewed. Diagnoses were confirmed by medical records. The attenuation of aortic wall abnormalities was measured. The observed attenuation threshold was validated using studies from 39 new subjects with a variety of aortic conditions. Results: The term “aortic dissection” was identified in 1206, and IMH in 124 patients’ reports. IMH was confirmed in 31 patients, 21 of whom had both unenhanced and contrast enhanced images. All 21 had pathologic CTA findings, and no CTA with IMH was normal. Attenuation of the aortic wall was greater than 45 HUs on the CTA images in all patients with IMH. When this threshold was applied to the new group, sensitivity for diagnosing AAS was 100% (19/19), and specificity 94% (16/17). Addition of unenhanced images did not improve accuracy. Conclusions: Measurements of aortic wall attenuation in CTA have a high negative predictive value for the diagnosis of acute aortic syndromes.

  1. Aortic root reimplantation procedure: a new milestone in aortic valve-sparing operations

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-08-01

    Full Text Available Aim: Emphasis in this study was placed on clinical and functional assessment of a modified "Florida Sleeve" procedure during surgical correction of ascending aorta aneurysms with concomitant aortic insufficiency.Methods: 32 patients with an aneurysm of the ascending aorta and aortic insufficiency underwent a modified "Florida Sleeve" procedure. The average follow-up was 17 (0-60 months. The average age of patients was 57±13 (23-73 years 56±13 years.Results: The expected 4-year cumulative survival rate was 84.3%. Overall freedom from aortic insufficiency in the late period was 88.9%. Median aortic regurgitation was 1+ (1; 2. Long-term follow-up revealed no valve-associated complications.Conclusion: The aortic root reimplantation procedure enables optimal correction of the existing lesions of the aortic root without performing aortic valve replacement and demonstrates stable clinical and functional outcomes in the long-term period.Key words: aortic aneurysm; aortic valve; valve-sparing operations.FundingThe study had no sponsorship.Conflict of interestThe authors declare no conflict of interest.

  2. Open-heart surgery using a centrifugal pump: a case of hereditary spherocytosis.

    Science.gov (United States)

    Matsuzaki, Yuichi; Tomioka, Hideyuki; Saso, Masaki; Azuma, Takashi; Saito, Satoshi; Aomi, Shigeyuki; Yamazaki, Kenji

    2016-08-26

    Hereditary spherocytosis is a genetic, frequently familial hemolytic blood disease characterized by varying degrees of hemolytic anemia, splenomegaly, and jaundice. There are few reports on adult open-heart surgery for patients with hereditary spherocytosis. We report a rare case of an adult open-heart surgery associated with hereditary spherocytosis. A 63-year-old man was admitted for congestive heart failure due to bicuspid aortic valve, aortic valve regurgitation, and sinus of subaortic aneurysm. The family history, the microscopic findings of the blood smear, and the characteristic osmotic fragility confirmed the diagnosis of hereditary spherocytosis. Furthermore, splenectomy had not been undertaken preoperatively. The patient underwent a successful operation by means of a centrifugal pump. Haptoglobin was used during the cardiopulmonary bypass, and a biological valve was selected to prevent hemolysis. No significant hemolysis occurred intraoperatively or postoperatively. There are no previous reports of patients with hereditary spherocytosis, and bicuspid aortic valve. We have successfully performed an adult open-heart surgery using a centrifugal pump in an adult patient suffering from hereditary spherocytosis and bicuspid aortic valve.

  3. Selective Heart, Brain and Body Perfusion in Open Aortic Arch Replacement.

    Science.gov (United States)

    Maier, Sven; Kari, Fabian; Rylski, Bartosz; Siepe, Matthias; Benk, Christoph; Beyersdorf, Friedhelm

    2016-09-01

    Open aortic arch replacement is a complex and challenging procedure, especially in post dissection aneurysms and in redo procedures after previous surgery of the ascending aorta or aortic root. We report our experience with the simultaneous selective perfusion of heart, brain, and remaining body to ensure optimal perfusion and to minimize perfusion-related risks during these procedures. We used a specially configured heart-lung machine with a centrifugal pump as arterial pump and an additional roller pump for the selective cerebral perfusion. Initial arterial cannulation is achieved via femoral artery or right axillary artery. After lower body circulatory arrest and selective antegrade cerebral perfusion for the distal arch anastomosis, we started selective lower body perfusion simultaneously to the selective antegrade cerebral perfusion and heart perfusion. Eighteen patients were successfully treated with this perfusion strategy from October 2012 to November 2015. No complications related to the heart-lung machine and the cannulation occurred during the procedures. Mean cardiopulmonary bypass time was 239 ± 33 minutes, the simultaneous selective perfusion of brain, heart, and remaining body lasted 55 ± 23 minutes. One patient suffered temporary neurological deficit that resolved completely during intensive care unit stay. No patient experienced a permanent neurological deficit or end-organ dysfunction. These high-risk procedures require a concept with a special setup of the heart-lung machine. Our perfusion strategy for aortic arch replacement ensures a selective perfusion of heart, brain, and lower body during this complex procedure and we observed excellent outcomes in this small series. This perfusion strategy is also applicable for redo procedures.

  4. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  5. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  6. Gas fired heat pumps

    International Nuclear Information System (INIS)

    Seifert, M.

    2006-01-01

    The condensing gas boiler is now state of the art and there is no more room for improvement in performance, technically speaking. The next logical step to improve the overall efficiency is to exploit ambient heat in combination with the primary source of energy, natural gas. That means using natural-gas driven heat pumps and gas-fired heat pumps. Based on this, the Swiss Gas Industry decided to set up a practical test programme enjoying a high priority. The aim of the project 'Gas-fired heat pump practical test' is to assess by field tests the characteristics and performance of the foreign serial heat pumps currently on the market and to prepare and promote the introduction on the market place of this sustainable natural-gas technology. (author)

  7. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  8. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  9. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  10. Mechanical vaccum pumps

    CERN Document Server

    Chew, A D

    2007-01-01

    This presentation gives an overview of the technology of contemporary primary and secondary mechanical vacuum pumps. For reference a brief history of vacuum and a summary of important and basic vacuum concepts are first presented.

  11. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.; Abdelghany, Mohamed A.; Elsayed, Mohannad Yomn; Elshurafa, Amro M; Salama, Khaled N.

    2014-01-01

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  12. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  13. GAS METERING PUMP

    Science.gov (United States)

    George, C.M.

    1957-12-31

    A liquid piston gas pump is described, capable of pumping minute amounts of gas in accurately measurable quantities. The pump consists of a flanged cylindrical regulating chamber and a mercury filled bellows. Sealed to the ABSTRACTS regulating chamber is a value and having a gas inlet and outlet, the inlet being connected by a helical channel to the bellows. A gravity check valve is in the gas outlet, so the gas passes through the inlet and the helical channel to the bellows where the pumping action as well as the metering is accomplished by the actuation of the mercury filled bellows. The gas then flows through the check valve and outlet to any associated apparatus.

  14. JET pump limiter

    International Nuclear Information System (INIS)

    Sonnenberg, K.; Deksnis, E.; Shaw, R.; Reiter, D.

    1988-01-01

    JET plans to install two pump limiter modules which can be used for belt-limiter, inner-wall and X-point discharges and, also, for 1-2s as the main limiter. A design is presented which is compatible with two diagnostic systems, and which allows partial removal of the pump limiter to provide access for remote-handling operations. The high heat-flux components are initially cooled during a pulse. Heat is removed between discharges by radiation and pressure contacts to a water-cooled support structure. The pumping edge will be made of annealed pyrolytic graphite. Exhaust efficiency has been estimated, for a 1-d edge model, using a Monte-Carlo calculation of neutral gas transport. When the pump limiter is operated together with other wall components we expect an efficiency of ≅ 5% (2.5 x 10 21 part/s). As a main limiter the efficiency increases to about 10%. (author)

  15. Types of Breast Pumps

    Science.gov (United States)

    ... called a bicycle horn pump, consists of a hollow rubber ball attached to a breast-shield. Some ... and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1-888- ...

  16. Development of a New Intravascular Low-Profile Device for Exclusion of Aortic Aneurysm: An Experimental Pilot Study

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Haberstroh, Joerg; Boos, Irene; Metz, Stephan; Langer, Mathias; Moliner, Manuel Maynar

    2004-01-01

    Purpose: To present a new intravascular device for the treatment of aorto-iliac aneurysms. Methods: This new device was tested in five dogs with abdominal aortic aneurysm created experimentally by overdilation of a balloon-expandable stent with a 16 or 18 mm wide PTA balloon catheter. The design of the device is based on a self-expanding aortic stent which consists of two stretchable circular frames filled with a textile Dacron mesh membrane that is suspended horizontally into the infrarenal abdominal aorta proximally to the aneurysm. The frames are part of a preshaped double helical structure that is introduced longitudinally through a catheter in a parallel fashion and forming the desired shape at the vessel site to be occluded. Two iliac stent-grafts are introduced in a low-profile status through the membrane sealing the aneurysm sac and holding the stent-grafts in place. After stent-graft expansion, a new bifurcation located more proximally than the natural one is created. The follow-up of the dogs was performed clinically and angiographically, and specimens were evaluated histomorphologically. Results: The membrane device can be introduced through a 9 Fr vascular sheath. Technical success was achieved in four of five dogs. Nine of ten stent-grafts could be fixed securely within the membrane, thus preventing dislocation. Aneurysms were excluded immediately, and blood flow to the external iliac arteries was restored by the stent-grafts. At 6-9 months follow-up of technically successful implanted devices, there were no endoleaks, no migration, no stenoses at contact sites between the implant material and vascular wall, and no stenosis or occlusion of the stent-grafts. At microscopic evaluation, the interspace between the membranes was filled with thrombotic material, thus ensuring exclusion of the aneurysm. Conclusion: This new device was found to be flexible, low profile and useful in excluding abdominal aortic aneurysm in the experimental setting

  17. A battery-operated pilot balloon time-signal generator

    Science.gov (United States)

    Ralph H. Moltzau

    1966-01-01

    Describes the design and construction of a 1-pound, battery-operated, time-signal transmitter, which is usable with portable radio or field telephone circuits for synchronizing multi-theodolite observation of pilot balloons.

  18. OCT evaluation of directional atherectomy compared to balloon angioplasty

    International Nuclear Information System (INIS)

    Marmagkiolis, Konstantinos; Lendel, Vasili; Cilingiroglu, Mehmet

    2015-01-01

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  19. OCT evaluation of directional atherectomy compared to balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Marmagkiolis, Konstantinos [Citizens Memorial Hospital Heart and Vascular Institute, Bolivar, MO (United States); Lendel, Vasili [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Cilingiroglu, Mehmet, E-mail: mcilingiroglu@yahoo.com [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Koc University, School of Medicine, Istanbul (Turkey)

    2015-09-15

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  20. Ballooning stability analysis of JET H-mode discharges

    International Nuclear Information System (INIS)

    O'Brien, D.P.; Galvao, R.; Keilhacker, M.; Lazzaro, E.; Watkins, M.L.

    1989-01-01

    Previous studies of the stability of a large aspect ratio model equilibrium to ideal MHD ballooning modes have shown that across the bulk of the plasma there exist two marginally stable values of the pressure gradient parameter α. These define an unstable zone which separates the first (small α) stable region from the second (large α) stable region. Close to the separatrix, however, the first and second regions can coalesce when the surface averaged current density, Λ, exceeds a critical value. The plasma in this region is then stable to ballooning modes at all values of the pressure gradient. In this paper we extend these results to JET H-mode equilibria using a finite aspect ratio ballooning formalism, and assess the relevance of ideal ballooning stability in these discharges. In particular we analyse shot 15894 at time 56 sec. which is 1.3 s into the H-phase. (author) 4 refs., 4 figs