  1. Intestinal cholesterol embolism resulting from intra-aortic balloon pumping: a case report

    OpenAIRE

    Yamaguchi, Satoshi; Kakazu, Masanori; Osamu, Arasaki

    2014-01-01

    Introduction Intra-aortic balloon pumping is used in elective percutaneous coronary intervention for increasing coronary blood flow. However, intra-aortic balloon pumping may decrease visceral blood flow and cause mesenteric ischemia by visceral artery obstruction. Case presentation We report the case of a 79-year-old Asian man in whom elective percutaneous coronary intervention was performed with intra-aortic balloon pumping. He died from mesenteric ischemia 25 hours after the procedure. Mic...

  2. Loss of Guide Wire: A Rare Complication of Intra-Aortic Balloon Pump Insertion

    Directory of Open Access Journals (Sweden)

    Manouchehr Hekmat

    2015-10-01

    Full Text Available At the final stages of a coronary artery bypass graft operation on a 64-year-old man, an experienced physician attempted to insert an intra-aortic balloon pump into the femoral artery via the Seldinger technique. However, while the balloon pump was being passed over the guide wire, the latter was completely lost.The guide wire should be held at the tip at all times to prevent passage into the vessel. Strict adherence to this rule will prevent guide-wire loss, which is, albeit rare and completely avoidable, a potentially life-threatening complication of central vein or artery catheterization, with reported fatality rates of up to 20% when the whole wire is lost. The literature contains several reports on guide-wire loss during central venous, arterial, and hemodialysis catheterization, but we report for the first time the loss of a guide wire as a rare complication of intra-aortic balloon pump insertion.

  3. Undiagnosed aortic dissection in patient with intra-aortic balloon pump

    OpenAIRE

    Monish S Raut; Arun Maheshwari; Manish Sharma

    2016-01-01

    60 years old lady presented with chest pain and was admitted in local hospital. Electrocardiogram was suggestive of anterior myocardial ischemia. Patient underwent coronary angiography which revealed severe triple vessles coronary artery disease. As patient was hemodynamically unstable and in cardiogenic shock, intraaortic balloon pump was inserted .IABP augmented diastolic blood pressure was less than unassisted systolic blood pressure despite setting maximum augmentation on IABP machine.

  4. Undiagnosed aortic dissection in patient with intra-aortic balloon pump.

    Science.gov (United States)

    Raut, Monish S; Maheshwari, Arun; Sharma, Manish

    2016-01-01

    60 years old lady presented with chest pain and was admitted in local hospital. Electrocardiogram was suggestive of anterior myocardial ischemia. Patient underwent coronary angiography which revealed severe triple vessles coronary artery disease. As patient was hemodynamically unstable and in cardiogenic shock, intraaortic balloon pump was inserted .IABP augmented diastolic blood pressure was less than unassisted systolic blood pressure despite setting maximum augmentation on IABP machine. PMID:27397468

  5. Undiagnosed aortic dissection in patient with intra-aortic balloon pump

    Science.gov (United States)

    Raut, Monish S.; Maheshwari, Arun; Sharma, Manish

    2016-01-01

    60 years old lady presented with chest pain and was admitted in local hospital. Electrocardiogram was suggestive of anterior myocardial ischemia. Patient underwent coronary angiography which revealed severe triple vessles coronary artery disease. As patient was hemodynamically unstable and in cardiogenic shock, intraaortic balloon pump was inserted .IABP augmented diastolic blood pressure was less than unassisted systolic blood pressure despite setting maximum augmentation on IABP machine. PMID:27397468

  6. Undiagnosed aortic dissection in patient with intra-aortic balloon pump

    Directory of Open Access Journals (Sweden)

    Monish S Raut

    2016-01-01

    Full Text Available 60 years old lady presented with chest pain and was admitted in local hospital. Electrocardiogram was suggestive of anterior myocardial ischemia. Patient underwent coronary angiography which revealed severe triple vessles coronary artery disease. As patient was hemodynamically unstable and in cardiogenic shock, intraaortic balloon pump was inserted .IABP augmented diastolic blood pressure was less than unassisted systolic blood pressure despite setting maximum augmentation on IABP machine.

  7. Undiagnosed aortic dissection in patient with intra-aortic balloon pump.

    Science.gov (United States)

    Raut, Monish S; Maheshwari, Arun; Sharma, Manish

    2016-01-01

    60 years old lady presented with chest pain and was admitted in local hospital. Electrocardiogram was suggestive of anterior myocardial ischemia. Patient underwent coronary angiography which revealed severe triple vessles coronary artery disease. As patient was hemodynamically unstable and in cardiogenic shock, intraaortic balloon pump was inserted .IABP augmented diastolic blood pressure was less than unassisted systolic blood pressure despite setting maximum augmentation on IABP machine.

  8. Virtual 5-French intra-aortic pumping using a Glidesheath Slender and 6-French intra-aortic balloon catheter

    International Nuclear Information System (INIS)

    Objectives: The aim of this study was to evaluate the feasibility and safety of the 6-Fr Glidesheath Slender, which has equivalent outer size to the conventional 5-Fr sheath, for use with the 6-Fr intra-aortic balloon pump (IABP) catheter. Methods: Between May 2014 and March 2015, 24 patients with acute coronary syndrome underwent percutaneous coronary intervention using a 6-Fr IABP catheter through a 6-Fr Glidesheath Slender for support. The adverse events, including access site complications, kinking of the sheath during the procedure, and any evidence of balloon pump failure, were retrospectively investigated. Results: Insertion of the IABP catheter through either the femoral or brachial artery was successful in all patients. The mean support time was 32.4 ± 22.0 h. No major hemorrhagic event or severe limb ischemia was observed. Kinking of the shaft occurred during insertion in one patient; however, the subsequent balloon pumping was well maintained and did not require exchange of the sheath or IABP catheter. No kind of IABP failure was observed. Conclusion: Although this sheath was originally designed to allow radial access, our results suggest that the use of the Glidesheath Slender is feasible for insertion of the 6-Fr IABP catheter through the brachial and femoral arteries, and may reduce vascular complications in patients who undergo percutaneous coronary intervention

  9. Virtual 5-French intra-aortic pumping using a Glidesheath Slender and 6-French intra-aortic balloon catheter

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: a-takahashi@wine.ocn.ne.jp; Taniguchi, Norimasa; Mizuguchi, Yukio; Yamada, Takeshi; Nakajima, Shunsuke; Hashimoto, Sho; Hata, Tetsuya

    2015-07-15

    Objectives: The aim of this study was to evaluate the feasibility and safety of the 6-Fr Glidesheath Slender, which has equivalent outer size to the conventional 5-Fr sheath, for use with the 6-Fr intra-aortic balloon pump (IABP) catheter. Methods: Between May 2014 and March 2015, 24 patients with acute coronary syndrome underwent percutaneous coronary intervention using a 6-Fr IABP catheter through a 6-Fr Glidesheath Slender for support. The adverse events, including access site complications, kinking of the sheath during the procedure, and any evidence of balloon pump failure, were retrospectively investigated. Results: Insertion of the IABP catheter through either the femoral or brachial artery was successful in all patients. The mean support time was 32.4 ± 22.0 h. No major hemorrhagic event or severe limb ischemia was observed. Kinking of the shaft occurred during insertion in one patient; however, the subsequent balloon pumping was well maintained and did not require exchange of the sheath or IABP catheter. No kind of IABP failure was observed. Conclusion: Although this sheath was originally designed to allow radial access, our results suggest that the use of the Glidesheath Slender is feasible for insertion of the 6-Fr IABP catheter through the brachial and femoral arteries, and may reduce vascular complications in patients who undergo percutaneous coronary intervention.

  10. The management of impending myocardial infarction using coronary artery by-pass grafting and an intra-aortic balloon pump.

    Science.gov (United States)

    Harris, P L; Woollard, K; Bartoli, A; Makey, A R

    1980-01-01

    Of 33 patients with impending myocardial infarction 25 were treated using a combination of coronary artery by-pass grafting and intra-aortic balloon pumping. Eight patients were treated with coronary artery by-pass grafting alone. Twenty-two of the 25 patients who were treated with the combined technique made a full recovery. Three patients sustained definite myocardial infarctions and one of these died. Five of the 8 patients treated by grafting alone suffered infarction and of these 3 died. The value of intra-aortic balloon pumping in combination with coronary artery by-pass grafting in the management of impending myocardial infarction is discussed.

  11. Flecainide overdose – support using an intra-aortic balloon pump

    Directory of Open Access Journals (Sweden)

    Brown Peter D

    2005-12-01

    Full Text Available Abstract Background Flecainide is an antiarrhythmic agent which is being used increasingly for the management of super-ventricular arrhythmias. Overdose with flecainide is frequently fatal with mortality reported as high as 22% due to arrhythmias, myocardial depression and conduction defects leading to electro-mechanical dissociation and asytole. Supportive measures are often required during the case and previously have included inotropes, extracorporeal membrane oxygenation and cardiopulmonary bypass. Case presentation A 47 year old lady presented to the emergency department with a four hour history of severe central chest pain. Her ECG showed atrial fibrillation and broad QRS complexes with a sine wave appearance. She had a past history of paroxysmal atrial fibrillation and significant psychiatric history. Following thrombolysis for a presumed myocardial infarction she developed cardiogenic shock with severely impaired left ventricular function. An intra-aortic balloon pump was inserted and coronary angiography demonstrated normal coronary arteries. With inotropic support she improved over 48 hours, with both her QRS duration and left ventricular function returning to normal. Biochemical testing following her discharge demonstrated significantly elevated levels of flecainide. Conclusion The use of an intra-aortic balloon pump is a useful supportive measure during the acute phase of flecainide overdose associated with severe myocardial depression.

  12. The Effects of Intra-Aortic Balloon Pump Support on Macrocirculation and Tissue Microcirculation in Patients with Cardiogenic Shock

    NARCIS (Netherlands)

    C.A. den Uil; W.K. Lagrand; M. van der Ent; L.S.D. Jewbali; J.J. Brugts; P.E. Spronk; M.L. Simoons

    2009-01-01

    Objectives: It was the aim of this study to evaluate the effects of intra-aortic balloon pump (IABP) counterpulsation on sublingual microcirculation as a model for tissue perfusion. Methods: In 13 patients with cardiogenic shock treated with IABP, the IABP assist ratio was reduced from 1: 1 to 1: 8

  13. Usefulness of Intra-Aortic Balloon Pump Counterpulsation in Patients With Cardiogenic Shock from Acute Myocardial Infarction

    NARCIS (Netherlands)

    J.M. Cheng; S.D.A. Valk; C.A. den Uil; M. van der Ent; W.K. Lagrand; M. van der Sande; R.T. van Domburg; M.L. Simoons

    2009-01-01

    Although intra-aortic balloon pump (IABP) counterpulsation is increasingly being used for the treatment of patients with cardiogenic shock from acute myocardial infarction, data on the long-term outcomes are lacking. The aim of the present study was to evaluate the 30-day and long-term mortality and

  14. The effectiveness of intra-aortic balloon pump for myocardial infarction in patients with or without cardiogenic shock: a meta-analysis and systematic review

    OpenAIRE

    Zheng, Xiao-yun; Wang, Yi; Chen, Yi; Wang, Xi; Chen, Lei; Li, Jun; Zheng, Zhi-gang

    2016-01-01

    Background Conflicting reports on the efficacy of intra-aortic balloon pump (IABP) during percutaneous coronary intervention (PCI) incited us to evaluate the utility of IABP in patients with acute myocardial infarction (AMI). Methods Randomized clinical trials comparing patients, who received IABP vs. control (no IABP) during PCI, were hand-searched from MEDLINE, Cochrane, and EMBASE databases using the terms “intra-aortic balloon pump, percutaneous coronary intervention, myocardial infarctio...

  15. Clinical efficacy of intra-aortic balloon pumping in treating patients with acute myocardial infarction with left main coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    赵昕

    2012-01-01

    Objective To evaluate the efficacy and safety of intra-aortic balloon pump(IABP) counter pulsation in the treatment of ST-segment elevation myocardial infarction(STEMI) with concurrent left main coronary artery(LM-CA) disease. Methods A retrospective analysis was performed

  16. The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome.

    LENUS (Irish Health Repository)

    Parissis, Haralabos

    2010-01-01

    BACKGROUND: The early and intermediate outcome of patients requiring intraaortic balloon pump (IABP) was studied in a cohort of 2697 adult cardiac surgical patients. METHODS: 136 patients requiring IABP (5.04%) support analysed over a 4 year period. Prospective data collection, obtained. RESULTS: The overall operative mortality was 35.3%. The "operation specific" mortality was higher on the Valve population.The mortality (%) as per time of balloon insertion was: Preoperative 18.2, Intraoperative 33.3, postoperative 58.3 (p < 0.05).The incremental risk factors for death were: Female gender (Odds Ratio (OR) = 3.87 with Confidence Intervals (CI) = 1.3-11.6), Smoking (OR = 4.88, CI = 1.23- 19.37), Preoperative Creatinine>120 (OR = 3.3, CI = 1.14-9.7), Cross Clamp time>80 min (OR = 4.16, CI = 1.73-9.98) and IABP insertion postoperatively (OR = 19.19, CI = 3.16-116.47).The incremental risk factors for the development of complications were: Poor EF (OR = 3.16, CI = 0.87-11.52), Euroscore >7 (OR = 2.99, CI = 1.14-7.88), history of PVD (OR = 4.99, CI = 1.32-18.86).The 5 years survival was 79.2% for the CABG population and 71.5% for the valve group. (Hazard ratio = 1.78, CI = 0.92-3.46). CONCLUSIONS: IABP represents a safe option of supporting the failing heart. The need for IABP especially in a high risk Valve population is associated with early unfavourable outcome, however the positive mid term results further justify its use.

  17. Intra-aortic balloon pump use does not affect the renal function in patients undergoing off pump coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Muniraju Geetha

    2011-01-01

    Full Text Available Renal dysfunction is known to occur during cardiac surgery. A few factors such as perioperative hypotension, use of potential nephrotoxic therapeutic agents, radio opaque contrast media in the recent past, intra-aortic balloon pump (IABP and cardiopulmonary bypass have been blamed as the contributing factors to the causation of postoperative renal dysfunction in cardiac surgical patients. At times, in patients with renal failure and low cardiac output status, one may face the dilemma if the use of IABP is safe. We undertook this prospective observational study to determine the degree of possible renal injury when IABP is used by measuring serial values of serum creatinine and Cystatin C. Elective patients scheduled for off-pump coronary artery bypass surgery requiring preoperative use of IABP were included in this study. Cystatin C and serum creatinine levels were checked at fixed intervals after institution of IABP. Twenty-two patients were eligible for enrolment to the study. There was no significant change in the values of serum creatinine; from the basal value of 1.10 ± 0.233 to 0.98 ± 0.363 mg /dL (P value >0.05. Cystatin C levels significantly decreased from the basal level of 0.98 ± 0.29 to 0.89 ± 0.23 (P value <0.05. Contrary to the belief, Cystatin C, the early indicator of renal dysfunction decreases suggesting absence of renal injury after the use of IABP. Absence of elevation of cystatin C levels in our study suggests the lack of potential of the IABP to cause renal dysfunction in patients who received elective IABP therapy preoperatively.

  18. A systematic review and meta-analysis of intra-aortic balloon pump therapy in ST-elevation myocardial infarction: should we change the guidelines?

    NARCIS (Netherlands)

    K.D. Sjauw; A.E. Engström; M.M. Vis; R.J. van der Schaaf; J.,Jr Baan; K.T. Koch; R.J. de Winter; J.J. Piek; J.G.P. Tijssen; J.P.S. Henriques

    2009-01-01

    Aims Intra-aortic balloon counterpulsation (IABP) in ST-segment elevation myocardial infarction (STEMI) with cardiogenic shock is strongly recommended (class IB) in the current guidelines. We performed meta-analyses to evaluate the evidence for IABP in STEMI with and without cardiogenic shock. Metho

  19. Temporal Trends of In-Hospital Mortality in Patients Treated with Intra-Aortic Balloon Pumping: A Nationwide Population Study in Taiwan, 1998-2008.

    Directory of Open Access Journals (Sweden)

    Chung-Han Ho

    Full Text Available Intra-aortic balloon pumping (IABP is widely used for hemodynamic support in critical patients with cardiogenic shock (CS. We examined whether the in-hospital mortality of patients in Taiwan treated with IABP has recently declined. We used Taiwan's National Health Insurance Research Database to retrospectively review the in-hospital all-cause mortality of 9952 (7146 men [71.8%] 18-year-old and older patients treated with IABP between 1998 and 2008. The mortality rate was 13.84% (n = 1377. The urbanization levels of the hospitals, and the number of days in the intensive care unit, of hospitalization, and of IABP treatment, and prior percutaneous coronary intervention (PCI were associated with mortality. Seven thousand six hundred thirty-five patients (76.72% underwent coronary artery bypass grafting (CABG surgery, and 576 (5.79% underwent high-risk PCI with IABP treatment. The number of patients treated with IABP significantly increased during this decade (ptrend < 0.0001, the in-hospital all-cause mortality for patients treated with IABP significantly decreased (ptrend = 0.0243, but the in-hospital all-cause mortality of patients who underwent CABG and PCI plus IABP did not decrease. In conclusion, the in-hospital mortality rate of IABP treatment decreased annually in Taiwan during the study period. However, high-risk patients who underwent coronary revascularization with IABP had a higher and unstable in-hospital mortality rate.

  20. Influence of preoperative coronary collateral circulation on in-hospital mortality in patients undergoing coronary artery bypass graft surgery with intra-aortic balloon pump support

    Institute of Scientific and Technical Information of China (English)

    Hasan Gungor; Cemil Zencir; Abraham Samuel Babu; Cagdas Akgullu; Ufuk Eryilmaz; Ali Zorlu; Mithat Selvi

    2014-01-01

    Background Outcomes in patients requiring coronary artery bypass graft (CABG) surgery have been improved with devices such as the intra-aortic balloon pump (IABP).Good coronary collateral circulation (CCC) has been shown to reduce mortality in patients with coronary artery disease (CAD).We aimed to investigate whether poor preoperative CCC grade is a predictor of in-hospital mortality in CABG surgery requiring IABP support.Methods Fifty-five consecutive patients who were undergoing isolated first time on-pump CABG surgery with IABP support were enrolled into this study and CCC of those patients was evaluated.Results Twenty-seven patients had poor CCC and 28 patients had good CCC.In-hospital mortality rate in poor CCC group was significantly higher than good CCC group (14 (50%) vs.4 (13%),P=0.013).Preoperative hemoglobin level (OR:0.752; 95% CI,0.571-0.991,P=0.043),chronic obstructive pulmonary disease (OR:6.731; 95% CI,1.159-39.085,P=0.034) and poor CCC grade (OR:5.750; 95% CI,1.575-20.986,P=0.008) were associated with post-CABG in-hospital mortality.Poor CCC grade (OR:4.853; 95% CI,1.124-20.952,P=0.034) and preoperative hemoglobin level (OR:0.624; 95% CI,0.476-0.954,P=0.026) were independent predictors of in-hospital mortality after CABG.Conclusion Preoperative poor CCC and hemoglobin are predictors of in-hospital mortality after CABG with IABP support.

  1. Clinical therapeutic efficacy of intra-aortic balloon pump as an adjuvant treatment after percutaneous coronary intervention in patients with coronary heart disease associated with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Zi-lan JING

    2015-06-01

    Full Text Available Objective To explore the clinical efficacy of intra-aortic balloon pump (IABP as an auxiliary treatment of percutaneous coronary intervention (PCI in patients with coronary heart disease (CHD associated with chronic kidney disease. Methods One hundred and twenty CHD patients with concomitant chronic kidney disease and receiving PCI in our hospital from Jan. 2000 to Jul. 2014, and 123 simple CHD patients without renal dysfunction, who had undergone PCI with concomitant IABP for the cardiac pump failure, cardiogenic shock, acute left heart failure, unstable angina pectoris (UP which was not allayed by medical treatment, or acute myocardial infarction (AMI, were selected for observation of preoperative condition, in-hospital mortality and prognosis of patients in two groups. Results There was no statistically significant difference in general clinical data including gender, age, and concomitant hypertension and diabetes, and preoperative blood lipid, AST, D-dimer, APTT, and international normalized ratio (INR showed also no statistically significant difference before surgery between two groups of patients (P>0.05. The difference in proportion of AMI, the left main trunk and (or three-branches involvement was of no statistical significance (P>0.05, but there was significant difference in the incidence of previous myocardial infarction, TnT, CK-MB, Cr, BUN, stent number, IABP application time (P0.05 between the two groups. Logistic regression analysis revealed that diabetes and the number of stents were independent risk factors for in-hospital and long-term mortalities. Conclusions By means of the effective cardiac assistance of IABP, CHD patients with renal insufficiency have the same short and long term clinical prognosis as simple CHD patients without renal dysfunction who has undergone PCI. Diabetes and the number of stents are independent risk factors for in-hospital and 1-year mortality. DOI: 10.11855/j.issn.0577-7402.2015.04.03

  2. Intraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational study

    OpenAIRE

    Boots Rob; Barnett Adrian G; Timms Daniel; Dunster Kimble; Geng Shureng; Bellapart Judith; Fraser John F

    2010-01-01

    Abstract Background The use of Intra-aortic counterpulsation is a well established supportive therapy for patients in cardiac failure or after cardiac surgery. Blood pressure variations induced by counterpulsation are transmitted to the cerebral arteries, challenging cerebral autoregulatory mechanisms in order to maintain a stable cerebral blood flow. This study aims to assess the effects on cerebral autoregulation and variability of cerebral blood flow due to intra-aortic balloon pump and in...

  3. Efficacy of Intra-aortic Balloon Pump before versus after Primary Percutaneous Coronary Intervention in Patients with Cardiogenic Shock from ST-elevation Myocardial Infarction

    Institute of Scientific and Technical Information of China (English)

    Lin Yuan; Shao-Ping Nie

    2016-01-01

    Background:Previous studies showed that patients with cardiogenic shock (CS) from ST-elevation acute myocardial infarction (STEMI) supported by intra-aortic balloon pump (IABP) before primary percutaneous coronary intervention (PCI) decreased the risk of in-hospital mortality than patients who received IABP after PCI.However,little evidence is available on the optimal order of IABP insertion and primary PCI.The aim of this study was to investigate the impact of the sequence of IABP support and PCI and its association with major adverse cardiac and cerebrovascular events (MACCEs).Methods:Data were obtained from 218 consecutive patients with CS due to STEMI in Beijing Anzhen Hospital between 2008 and 2014,who were treated with IABP and PCI.The patients were divided into two groups:Group A in whom IABP received before PCI (n =106)and Group B in whom IABP received after PCI (n =112).We evaluated the myocardial perfusion using myocardial blush grade and resolution of ST-segment elevation.The primary endpoint was 12-month risk of MACCE.Results:Most baseline characteristics were similar in patients between the two groups.However,patients received IABP before PCI were associated with a delay of door-to-balloon time (DBT) and higher troponin Ⅰ level (P < 0.05).However,myocardial perfusion was significantly improved in patients treated with IABP before PCI (P < 0.05).Overall,IABP support before PCI was not associated with significantly lower risk of MACCE (P > 0.05).In addition,risk of all-cause mortality,bleeding,and acute kidney injury (AKI)was similar between two groups (P > 0.05).Multivariate analysis showed that DBT (odds ratio [OR] 2.5,95% confidence interval [CI]1.1-4.8,P=0.04),IABP support after PCI (OR 5.7,95% CI 2.7-8.4,P=0.01),and AKI (OR 7.4,95% CI 4.9-10.8,P=0.01) were the independent predictors of mortality at 12-month follow-up.Conclusions:Early IABP insertion before primary PCI is associated with improved myocardial perfusion although DBT

  4. Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis.

    Science.gov (United States)

    Nwaejike, Nnamdi; Mills, Keith; Stables, Rod; Field, Mark

    2015-03-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was, in patients with severe aortic stenosis, can balloon valvuloplasty be used as a bridge to aortic valve replacement? Altogether 463 papers were found using the reported search, of which 11 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude that balloon aortic valvuloplasty is recommended as a bridge to aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI) in patients with severe symptomatic aortic stenosis. Institutional practices, local and logistic factors can affect patient selection and management approaches to severe aortic stenosis, but having the facility to offer balloon aortic valvuloplasty (especially in the TAVI era) provides another management option for patients who would otherwise have been considered unacceptably high risk for aortic valve surgery. The increased incidence of balloon aortic valvuloplasty mirrors the increase in the use of TAVI with a sharp increase in activity from 2006. Success rates for bridging from balloon aortic valvuloplasty to definite surgical intervention are in the range 26.3-74%, with AVR or TAVI occurring within 8 weeks to 7 months. Complications from balloon aortic valvuloplasty such as aortic regurgitation (AR) can be managed successfully. Up to 40% of patients selected by balloon aortic valvuloplasty to have TAVI or AVR do not have these procedures within 2 years. While most of these patients are excluded for objective clinical reasons such as terminal disease/malignancy or other persistent contraindication, some patients refuse definitive treatment and others die while on the waiting list. Outcomes in patients bridged to AVR/TAVI are better than in patients treated with balloon aortic valvuloplasty

  5. [Intra-graft balloon pumping--a clinical case report].

    Science.gov (United States)

    Nagata, M; Tashiro, T; Tanaka, K; Haruta, Y; Todo, K

    1991-12-01

    A 29-year-old female underwent tube graft replacement of distal aortic arch and descending aorta for dissecting aneurysm. After 42 minutes of aortic cross-clamping the patient was initially weaned satisfactorily from cardiopulmonary bypass (CPB). However, cardiac arrhythmia and cardiac arrest necessitated reestablishment of CPB. Electro-cardiography showed inferior myocardial infarction. To wean CPB intraaortic balloon pumping (IABP) was mandatory. But because of dissecting aortic aneurysm IABP in conventional method was contra-indicated. Intra graft balloon pumping (IGBP) was initiated while the patient was on full CPB. A low-porosity woven Dacron tube graft (22 mm) was anastomosed end-to-side to ascending aorta. A balloon was inserted into the tube graft to establish IGBP. This IGBP provided effective circulatory assist. The patient was weaned from CPB 1 hours after reestablishment of IGBP. Postoperative course was stable. The patient was returned to the operating room for removal of the balloon 3 days postoperatively. We reported the case for whom IGBP was effective. IGBP was effective circulatory support for the patient when conventional use of IABP was contra-indicated. PMID:1774515

  6. ROLE OF INTRA-AORTIC BALLOON PUMP IN THE MANAGEMENT OF CARDIOGENIC SHOCK%主动脉内球囊反搏在心脏术后心源性休克中的应用

    Institute of Scientific and Technical Information of China (English)

    陈在金; 阮淑妹; 董明

    2011-01-01

    [Objective] To evaluate the role of intra-aortic balloon pump (IABP) in the management of cardiogenic shock. [Methods] Intra-aortic balloon pump was used in the treatment of 13 patients with cardiogenic shock after cardiac operation. The operations included 9 cases of coronary artery bypass grafting, 2 cases of mitral valve replacement combined with coronary artery bypass grafting and 1 case of aortic valve replacement. [Results] 9 (69.2%) patients recovered after IABP, with the successful rate of 69.2%. [Conclusion] IABP is effective in the management of cardiogenic shock.%[目的]对应用主动脉内球囊反搏(IABP)治疗心脏术后心源性休克的疗效进行评估.[方法]对13例心脏手术后并发心源性休克及低心排血量综合征的患者,应用IABP治疗.其中,单纯冠状动脉搭桥术9例,二尖瓣替换加冠状动脉搭桥术2例,再次行主动脉瓣替换术1例,再次行二尖瓣替换加三尖瓣替换术1例.[结果]9例患者心功能得到明显改善,度过围术期,顺利脱离IABP,成功率为69.2% (9/13).[结论]IABP是心脏术后心源性体克的有效手段,能明显降低病死率.

  7. Open surgical repair of abdominal aortic aneurysm: Proximal aortic control by endoaortic balloon - A novel approach

    OpenAIRE

    Balakrishnan Soundaravalli; Palaniappan, M.; Rajani Sundar; Chandrasekar, P.

    2012-01-01

    Patients with infrarenal abdominal aortic aneurysm with unfavorable anatomy for endovascular aneurysm repair have to undergo open surgical repair. Open surgery has its own morbidity in terms of proximal clamping and declamping, bleeding and prolonged hospital stay and mortality. We present two such patients with juxtarenal abdominal aortic aneurysm who underwent open surgical repair. The proximal aortic control during open surgical repair of the aneurysm was achieved by endoaortic balloon occ...

  8. Open surgical repair of abdominal aortic aneurysm: Proximal aortic control by endoaortic balloon - A novel approach

    Directory of Open Access Journals (Sweden)

    Balakrishnan Soundaravalli

    2012-01-01

    Full Text Available Patients with infrarenal abdominal aortic aneurysm with unfavorable anatomy for endovascular aneurysm repair have to undergo open surgical repair. Open surgery has its own morbidity in terms of proximal clamping and declamping, bleeding and prolonged hospital stay and mortality. We present two such patients with juxtarenal abdominal aortic aneurysm who underwent open surgical repair. The proximal aortic control during open surgical repair of the aneurysm was achieved by endoaortic balloon occlusion technique.

  9. Balloon aortic valvuloplasty in pregnancy with severe aortic stenosis and infective endocarditis

    Directory of Open Access Journals (Sweden)

    Vinotha

    2012-12-01

    Full Text Available Twenty seven year old lady, previously diagnosed to have aortic stenosis, presented to the obstetric outpatient department at 19 weeks of gestation with fever and breathlessness, NYHA class 4, for one week. Two D Echo revealed left ventricular hypertrophy, a severely stenosed, calcified bicuspid aortic valve, with vegetations on aortic and mitral valves and severe mitral regurgitation. Blood cultures grew nutrionally variant streptococci and she was treated with crystalline penicillin and gentamicin. She stabilised clinically by 21 weeks, by which time, the risk of termination of pregnancy was comparable to continuing the pregnancy. She underwent balloon aortic valvuloplasty. Post balloon aortic valvuloplasty, she was stable. At 34+2 weeks, she underwent emergency LSCS, the indication being intrauterine growth restriction with fetal compromise and breech presentation. She delivered a baby girl, 1.6 kg, Apgar 9 & 10. Our case report highlights the fact that a timely, balloon aortic valvuloplasty can be life saving for patients with pregnancy complicated by severe aortic stenosis and infective endocarditis. [Int J Reprod Contracept Obstet Gynecol 2012; 1(1.000: 69-71

  10. IABP在心脏瓣膜病手术治疗中的应用%Intra-aortic Balloon Pump in the Treatment of Valvular Heart Disease Following Heart Surgery.

    Institute of Scientific and Technical Information of China (English)

    任崇雷; 姜胜利; 高长青; 李伯君; 肖苍松

    2011-01-01

    目的 总结主动脉内球囊反搏泵(intra-aortic balloon pump,IABP)在心脏瓣膜置换术后的应用经验.方法 回顾分析解放军总医院心血管外科2008年10月-2010年8月共施行体外循环瓣膜置换手术450例,共有20例患者于术中或术后应用1ABP治疗,其中男性9例,女性11例,年龄28~72岁,平均年龄54.60±10.94岁,术前诊断为风湿性心脏瓣膜病者12例,心脏术后瓣膜病复发或再发者3例,心内膜炎者2例,先天性心脏瓣膜病者2例,退行性心脏瓣膜病者1例;其中术前冠脉造影明确合并冠心病6例,术前心脏超声检查巨大左心房2例,小左心室6例,左心房大量血栓5例,三尖瓣重度关闭不全并中重度肺动脉高压10例;心功能NYHA分级Ⅱ级1例,Ⅲ级13例、Ⅳ级6例.其中双瓣置换术3例,二尖瓣置换术10例,主动脉瓣置换4例,二尖瓣成形、三尖瓣置换及人工二尖瓣瓣周漏修补各1例;同期冠脉搭桥术4例,心内血栓清除5例.结果 全组20例患者手术体外循环时间174.0±71.5min,心肌阻断时间106.0±43.8min.因术中心脏复苏后不能停体外循环或停机后低心排出量应用IABP 10例,术后因各种原因的低心排出量应用IABP 10例.全组20例患者行IABP辅助治疗时间20~120h,平均治疗时间53.0±28.3h;早期存活17例(85%),死亡3例(15%),死亡原因分别为低心排出量综合征、右心衰竭及多脏器衰竭,无IABP相关并发症.结论 IABP可应用于合并冠心病、小左心室、重度肺动脉高压、心功能减低等重症心脏瓣膜病术后治疗,适用于术中无法脱离体外循环、术后药物无法纠正的低心排出量综合征、围术期因心肌缺血引起的急性心肌梗死、严重心律失常等情况.对有指征的瓣膜置换术后患者积极正确地应用IABP,可改善患者血流动力学指标,提高抢救成功率.%Objective To review and summarize the clinical results and experiences of the intra - aortic balloon

  11. Anticoagulation therapy in intra-aortic balloon counterpulsation:Does IABP really need anti-coagulation?

    Institute of Scientific and Technical Information of China (English)

    JIANG Chen-yang(蒋晨阳); ZHAO Li-li(赵莉莉); WANG Jian-an(王建安); SAN Jiang(单江); MOHAMMOD Balgaith

    2003-01-01

    Objective: To investigate if intra-aortic balloon pump(IABP) is contraindicated without anticoagulation therapy. Methods: Some 153 IABP patients in the King Abdulaziz Cardiac Center(KSA) were randomly assigned into two groups. Anticoagulation group(Group A) consisted of 71 patients who were given heparin intravenously with target aPTT 50-70 seconds. Non-anticoagulation group(Group B) consisted of 82 patients without intravenous heparin during balloon pumping. Hematological parameters including platelet count, D-dimer, Plasminogen activator inhibitor-1(PAI-1) and fibrinogen degradation products(FDP) were checked respectively at the point of baseline, 24 hours, 48 hours and 24 hours post IABP counterpulsation. Clot deposits on balloon surface, vascular complications from IABP including bleeding and limb ischemia were recorded. Results: Platelet count and PAI-1 level decreased at 24 hours and 48 hours in both groups (P0.05). Three patients in Group A and 2 patients in Group B developed minor limb ischemia(P>0.05). No major limb ischemia in either group. Two patients in Group A suffered major bleeding and required blood transfusion or surgical intervention, whereas no patient had major bleeding in Group B. Eight patients had minor bleeding in Group A, but only 2 patients in Group B(P<0.05). No clot deposit developed on IABP surface in either group. Conclusion: IABP is safe without routine anticoagulation therapy. Selecting appropriate artery approach and early detection intervention are key methods for preventing complications.

  12. Anticoagulation therapy in intra-aortic balloon counterpulsation: Does IABP really need anti-coagulation ?

    Institute of Scientific and Technical Information of China (English)

    蒋晨阳; 赵莉莉; 王建安; 单江; MOHAMMODBalgaith

    2003-01-01

    Objective: To investigate if intra-aortic balloon pump(IABP) is contraindicated without anticoag-ulation therapy. Methods: Some 153 IABP patients in the King Abdulaziz Cardiac Center(KSA) were random-ly assigned into two groups. Anticoagulation group( Group A) consisted of 71 patients who were given heparin intravenously with target aPTT 50 - 70 seconds. Non-anticoagulation group( Group B) consisted of 82 patients without intravenous heparin during balloon pumping. Hematological parameters including platelet count, D-dimer, Plasminogen activator inhibitor-1 (PAI-1) and fibrinogen degradation products(FDP) were checked respectively at the point of baseline, 24 hours, 48 hours and 24 hours post IABP counterpulsation. Clot deposits on balloon surface, vascular complications from IABP including bleeding and limb ischemia were recorded.Results: Platelet count and PAI-1 level decreased at 24 hours and 48 hours in both groups ( P 0.05) . Three patients in Group A and 2 patients in Group B developed minor limb ischemia( P > 0.05). No major limb ischemia in either group. Two patients in Group A suffered major bleeding and required blood transfusion or surgical intervention, whereas no patient had major bleeding in Group B. Eight patients had minor bleeding in Group A, but only 2 patients in Group B ( P <0.05). No clot deposit developed on IABP surface in either group. Conclusion: IABP is safe without routine anticoagulation therapy. Selecting appropriate artery approach and early detection intervention are key methods for preventing complications.

  13. Externalization of a stiff guide wire via the radial artery: a new technique to facilitate advancement of an Inoue balloon across the aortic valve in patients with aortic stenosis undergoing antegrade balloon aortic valvuloplasty.

    Science.gov (United States)

    Kato, Hiroshi; Kubota, Shoichi; Goto, Takuya; Haba, Toshihiro; Yamamoto, Makoto

    2016-04-01

    An 84-year-old woman with aortic stenosis underwent antegrade balloon aortic valvuloplasty (BAV). After transseptal puncture, we introduced a 7-Fr wedge catheter into the left ventricle and across the aortic valve. We then inserted a 0.032-inch soft guide wire, and the tip of the guide wire was advanced into the brachial artery and exchanged for a stiff guide wire. We externalized the tip of the stiff guide wire from the radial artery. Finally, we advanced an Inoue balloon (Toray, Tokyo, Japan) across the aortic valve and inflated the balloon. Transradial externalization makes antegrade BAV an even less invasive procedure. PMID:25862651

  14. Latex micro-balloon pumping in centrifugal microfluidic platforms.

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Madou, Marc

    2014-03-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-step processes on a single microfluidic disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping mechanisms have been designed to study the pump performance at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data show that the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, a desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon.

  15. Isothermal pumping analysis for high-altitude tethered balloons

    OpenAIRE

    Kuo, Kirsty A.; Hunt, Hugh E.M.

    2015-01-01

    High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal...

  16. Intra-aortic balloon pumping in myocardial infarction patients with cardiogenic shock and long-term (≧ 10 days) treatment of research%主动脉内球囊反搏术在心肌梗塞并心源性休克长期(≥10d)应用治疗方面的研究

    Institute of Scientific and Technical Information of China (English)

    余天浩; 李瑜辉; 黄丹华

    2012-01-01

    [目的]主动脉内球囊反搏术被广泛应用于治疗心肌梗塞并心源性休克,然而,使用主动脉内球囊反搏术的安全期及其长期应用可能引起的并发症目前仍未能确定,本研究主要是观察需长期(≥10 d)应用主动脉内球囊反搏术治疗的患者,并预计他们的预后.[方法]88例患者应用主动脉内球囊反搏术治疗,其中41例患者应用长期(≥10 d)主动脉内球囊反搏术治疗,对比长期(≥10 d)治疗患者和常规治疗患者的治疗效果.[结果]IABP长期治疗组(≥10 d)和常规治疗组治疗前除血氧外各项指标均不存在显著差异,治疗后6h、24 h、72 h的心率、收缩压、舒张压、呼吸、血氧均不存在显著差异(P>0.05);相对于治疗前,患者在IABP治疗后6h收缩压、血氧均明显改善(P<0.05),IABP治疗后24 h、72 h心率、呼吸、血氧、收缩压均明显改善(P<0.05);相对于治疗前,患者的平均动脉压、心脏指数、主动脉内舒张压均有提高(P< 0.01);多变量对数回归模型分析提示IABP长期(≥10 d)治疗不影响患者的死亡率;IABP治疗和呼吸支持时间与PCI治疗时间的相关分析提示,越早进行PCI治疗,则应用IABP治疗和呼吸支持时间越短.[结论]主动脉内球囊反搏术的长期(≥10d)应用不影响生存率,是可行和安全的.%[Objective]To observe long-term (≧ 10 days) application of intra-aortic balloon pump in the treatment for patients and predict their prognosis.The intra-aortic balloon pump was used to treat myocardial infarction patients and cardiogenic shock,however,the safe period of intra-aortic balloon pump operation and the complications caused by long-term application were not yet to be determined.[Methods]A total of 88 patients including 71 males,17females,were applied with intra-aortic balloon pump for treatment.Among them,41 patients in the use of long-term (≧10 days) application of intra-aortic balloon pump for treatment.All samples

  17. Effects of intra-aortic balloon pump combined with emergency PCI in AMI patients complicated cardiogenic shock%急诊PCI联合主动脉内球囊反搏对急性心肌梗死合并心源性休克的疗效

    Institute of Scientific and Technical Information of China (English)

    李建伟; 王曼; 谢芳元; 董昕

    2012-01-01

    Objective: To study clinical efficacy of intra- aortic balloon pump (IABP) combined with emergency percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) complicated cardiogenic shock. Methods: Clinical data of 16 AMI complicated cardiogenic shock patients undergoing PCI combined with IABP were retrospectively studied. Results: All patients successfully underwent IABP and PCI. IABP duration was 20~190 (70. 6+ 37. 2) h. Bleeding of local puncture sites occurred in three cases (18. 75%) and they were stopped after compression. One case (6.25%) died during admission and there were no other severe complications besides one case death. Conclusion: Intra - aortic balloon pump combined with percutaneous coronary intervention is safe and effective in AMI patients with cardiogenic shock.%目的:探讨经皮冠状动脉介入治疗(PCI)联合主动脉球囊反搏术(IABP)治疗急性心肌梗死(AMI)心源性休克患者的临床疗效.方法:回顾性分析16例联合IABP行PCI治疗的AMI合并心源性休克患者的临床资料.结果:16例患者均成功置入IABP及行PCI术,IABP使用时间20~190 (70.6±37.2)h,3例(18.75%)出现局部穿刺部位出血,经压迫后出血停止,除住院期间死亡1例(6.25%),无重大并发症.结论:对于心源性休克患者,联合主动脉球囊反搏术行经皮冠状动脉介入治疗安全、有效.

  18. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    International Nuclear Information System (INIS)

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification

  19. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Schuhbaeck, Annika, E-mail: annika.schuhbaeck@uk-erlangen.de [Department of Cardiology, University of Erlangen, Erlangen (Germany); Weingartner, Christina [Department of Cardiology, University of Gießen, Giessen (Germany); Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed [Department of Cardiology, University of Erlangen, Erlangen (Germany); Rixe, Johannes; Nef, Holger [Department of Cardiology, University of Gießen, Giessen (Germany); Schneider, Christian [Department of Radiology, University of Gießen, Giessen (Germany); Lell, Michael; Uder, Michael [Department of Radiology, University of Erlangen, Erlangen (Germany); Ensminger, Stephan [Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Ruhr-University Bochum, Bad Oeynhausen (Germany); Feyrer, Richard; Weyand, Michael [Department of Cardiothoracic Surgery, University of Erlangen, Erlangen (Germany); Achenbach, Stephan [Department of Cardiology, University of Erlangen, Erlangen (Germany)

    2015-07-15

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification.

  20. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    OpenAIRE

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a...

  1. Effects of intra-aortic balloon pump on the blood flow to coronary grafts%主动脉内球囊反搏对冠状动脉旁路血管血流量的影响

    Institute of Scientific and Technical Information of China (English)

    苏丕雄; 刘文超; 高杰; 刘岩; 张希涛; 颜钧; 顾松

    2009-01-01

    目的 探讨主动脉内球囊反搏(IABP)应用前、后冠状动脉旁路移植术(cABG)各心动周期血流量变化特点,为临床合理应用IABP增加CABG术后旁路血管血流及心肌灌注提供理论基础.方法 2006年9月至2008年3月,302例CABG中22例术前或术中置入IABP,置人者均有明显应用IABP指征,共做旁路血管52支,其中动脉旁路血管24支,静脉旁路血管28支.52支旁路血管均在鱼精蛋白中合肝素后应用瞬时血流测量技术(TTFM)记录IABP起搏前、后各心动周期即心脏收缩期、舒张期、全心动周期血流变化指标:血流波形、平均血流量(Vmean)、每分钟速度时间积分(VTI)、弹力指数(PI值),同时记录桡动脉收缩压、舒张压及心率.结果 52支旁路血管均通畅,与不用IABP相比舒张期平均血流量[(58.05±29.10)ml/min对(46.14±40.48)ml/min,P0.05]、每分钟速度时间积分[(42.77±22.25)ml对(39.65±20.03)ml,P>0.05]没有明显变化;PI值没有明显变化(2.78±1.37对3.21±2.82,P>0.05).IABP应用前后心率[(83±13)次/min对(86±11)次/min,P>0.05]、桡动脉收缩压[(91.12±11.73)mmHg(1 mm Hg=0.133 kPa)对(88.23±15.47)mmHg,P>0.05]、桡动脉舒张压[(56.33±9.25)mmHg对(52.81±10.11)mmHg,P>0.05]无明显变化.结论 IABP不能明显增加旁路血管总的血流量,但心动周期各时期血流分布有较大变化,IABP增加旁路血管血流量主要是心脏舒张期,而心脏收缩期旁路血管血流量有一定下降.%ObJective Intra-aortic balloon pump(IABP) improves postoperative cardiac function substantially and reduces mor-rarity in the patients undergoing coronary artery bypass grafting(CABG) surgery by decreasing the postload of the heart and increasing the blood flow to the coronary artery. However, the effects of IABP on the blood flow to the coronary artery bypass grafts during differ-ent periods of the cardiac cycle, including systolic, diastolic and pan-cardiac cycle, remains unclear. Assess the changes in

  2. Perioperative intra-aortic balloon counterpulsation in a patient with myocardium at risk undergoing urgent noncardiac surgery

    Directory of Open Access Journals (Sweden)

    Tim Nebelsiek

    2015-01-01

    Full Text Available We are presenting the case of a 76-year-old female scheduled for major abdominal surgery. Her past medical history was remarkable for a three-vessel coronary artery disease, with a severely impaired left ventricular function. She had already undergone complex coronary artery bypass surgery. Currently, she presented with the rare constellation of a hemodynamic relevant and interventionally intractable stenosis of the left subclavian artery proximal to a crucial coronary bypass from left internal mammary artery to the left anterior descending. To protect this patient from perioperative myocardial infarction, an intra-aortic balloon pump was successfully used.

  3. Value discussion of intra-aortic balloon pump in the treatment of my-ocardial infarction combined with cardiogenic shock%主动脉内球囊反搏治疗心肌梗死合并心源性休克的价值探讨

    Institute of Scientific and Technical Information of China (English)

    何天民

    2014-01-01

    目的:探讨主动脉内球囊反搏治疗心肌梗死合并心源性休克的临床价值。方法选取本院收治的80例心肌梗死合并心源性休克患者作为研究对象,随机分为两组,各40例,观察组采用主动脉内球囊反搏,对照组采用急诊心脏介入溶栓治疗,比较两组治疗后的心排血量、平均动脉压变化情况及治疗后出血相关并发症。结果观察组心排血量、平均动脉压显著高于对照组,差异有统计学意义(P<0.05),观察组消化道出血、皮下血肿及泌尿道出血的发生率显著低于对照组,差异有统计学意义(P<0.05)。结论主动脉内球囊扩张能有效提高心肌梗死合并心源性休克患者的心排血量及动脉血压,减少出血相关并发症,值得临床重视。%Objective To explore the value of intra-aortic balloon pump in the treatment of myocardial infarction com-bined with cardiogenic shock. Methods 80 cases with myocardial infarction combined with cardiogenic shock were se-lected and randomly divided into two groups,40 cases in each group.The observation group were used intra-aortic bal-loon pump,the control group were used emergency cardiac interventional thrombolytic.Cardiac output,mean arterial pressure changes,and bleeding complications of post-treatment was compared after treatment. Results Cardiac output results and mean arterial pressure in the observation group were significantly higher than those of control group,with statistical difference (P<0.05).The incidence rate of gastrointestinal bleeding,hematoma and urinary tract bleeding were significantly lower than those of control group,with statistical difference(P<0.05). Conclusion Intra-aortic balloon pump for myocardial infarction combined with cardiogenic shock can effectively improve cardiac output and arterial blood pressure and reduce bleeding-related complications,and it is worthy of attention.

  4. Flow modulation algorithms for intra-aortic rotary blood pumps to minimize coronary steal.

    Science.gov (United States)

    Ising, Mickey S; Koenig, Steven C; Sobieski, Michael A; Slaughter, Mark S; Giridharan, Guruprasad A

    2013-01-01

    myocardial hypoxia and improve patient outcomes. However, even with flow modulation, IARBP support provides a smaller improvement in myocardial supply demand ratio compared to ventricular assist devices and intra-aortic balloon pumps. PMID:23644613

  5. Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2009-06-01

    ão.OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning

  6. 急性广泛前壁心肌梗死合并心源性休克患者直接PCI术前联合应用IABP的疗效评估%Intra-aortic balloon pump combined with primary percutaneous coronary intervention for acute extensive anterior myocardial infarction complicated with cardiogenic shock

    Institute of Scientific and Technical Information of China (English)

    曾维英; 陈平; 李仪; 罗燕华

    2012-01-01

    目的 探讨主动脉内球囊反搏( intra-aortic balloon pump,IABP)支持下行直接经皮冠状动脉介入术( percutaneous coronary intervention,PCI)对急性广泛前壁心肌梗死并心源性休克患者的疗效.方法 选择2008年1月至2012年1月我院收治的急性广泛前壁心肌梗死并心源性休克患者32例,均行直接PCI术,其中20例术前应用IABP的为IABP组,12例未应用IABP的为对照组;观察两组患者术后即时及术后2周心脏左室射血分数( left ventricular ejective fraction,LVEF)值.结果 IABP组及对照组患者术后2周心功能[( 45.4±7.3),(40.5±6.2)]较PCI术后即时[(37.4±7.1),(36.8±6.7 )]均有明显改善(P<0.05),且IABP组患者心功能(45.4±7.3)较对照组(40.5±6.2)改善更为显著(P<0.05).结论 急性广泛前壁心肌梗死并心源性休克患者行直接PCI术前联合应用IABP能更有效地改善患者术后心功能.%Objective To explore the efficacy of intra-aortic balloon pump ( IABP ) combined with percutaneous coronary intervention ( PCI ) for patients with acute extensive anterior myocardial infarction complicated with cardiogenic shock.Methods Among 32 patients with acute extensive anterior myocardial infarction complicated with cardiogenic shock who underwent PCI,20 patients received IABP before PCI ( IABP gronp ) and 12 received no IABP ( control group ).Left ventricular ejective fraction was observed immediately and 2 weeks after PCI in the two groups.Results Two weeks after the procedure,heart function was significantly improved in IABP group [( 37.4 ± 7.1 ),( 45.4 ± 7.3 )]and the control group[ ( 36.8 ± 6.7 ),( 40.5 ± 6.2 )],as compared with that detected immediatedly after the procedure ( P< 0.05 ).Heart function improved more significantly in IABP group than in the control group [( 45.4 ± 7.3 )vs.( 40.5 ± 6.2 ),P < 0.05].Conclusions IABP combined with PCI can effectively improve postoperative left ventricular ejective fraction in patients with acute

  7. Clinical analysis of percutaneous coronary intervention combined with intra-aortic balloon pump in the treatment of acute myocardial infarction complicated with cardiogenic shock%主动脉球囊反搏联合经皮冠状动脉介入治疗急性心肌梗死合并心源性休克的临床分析

    Institute of Scientific and Technical Information of China (English)

    靳志峰

    2016-01-01

    目的 探讨对急性心肌梗死合并心源性休克患者行主动脉球囊反搏联合经皮冠状动脉介入治疗的临床效果.方法 随机选取本院2013年1月至2015年5月收治的急性心肌梗死合并心源性休克患者41例,采用急诊经皮冠状动脉介入治疗(PCI)联合主动脉球囊反搏(IABP)方案对所有患者进行治疗,对治疗前后患者的每小时尿量变化、平均动脉压(MAP)、平均静脉压(CVP)、心脏指数(CI)和肺毛细血管楔压(PCWP)进行观察记录,并对结果进行分析.结果 经过IABP联合急诊PCI治疗后,41例患者的每小时尿量、MAP及CI明显上升,而PCWP、CVP同治疗前相比明显下降,差异有统计学意义(P<0.05).结论 对急性心肌梗死合并心源性休克患者实施IABP联合PCI,能够有效改善患者的心肌功能,对于保障患者的生命安全具有十分重要的临床意义.%Objective To investigate the clinical effect of percutaneous coronary intervention combined with intra-aortic balloon pump in the treatment of patients with acute myocardial infarction complicated with cardiogenic shock.Methods 41 cases of acute myocardial infarction complicated with cardiogenic shock admitted in our hospital from January 2013 to May 2015 were randomly selected.All patients were treated with emergency percutaneous coronary intervention (PCI) combined with intra-aortic balloon pump (IABP).The urine volume change in every hour,average MAP,average CVP,CI,and PCWP were observed and recorded,the observation result was analyzed.Results After 41 patients received IABP and emergency PCI,urine volume per hour,MAP,CI increased significantly,but PCWP,CVP decreased significantly compared with the conditions before treatment,with statistically significant differences (P<0.05).Conclusion IABP combined with PCI can improve myocardial function of patients with acute myocardial infarction complicated with cardiogenic shock,which has very important clinical significance in

  8. Clinical analysis of intra-aortic balloon pump counterpulsation in adjuvant treatment of AMI complicated with cardiogenic shock%主动脉内球囊反搏辅助治疗急性心肌梗死合并心源性休克的临床分析

    Institute of Scientific and Technical Information of China (English)

    崔晓琼; 李彤; 胡晓旻; 张文芳; 刘迎午; 王禹; 张强; 稂与恒

    2011-01-01

    目的 分析主动脉内球囊反搏(IABP)辅助治疗急性心肌梗死合并心源性休克的临床疗效.方法 选择急性心肌梗死合并心源性休克的老年患者50例,观察置入IABP前后患者血流动力学变化、心功能、IABP并发症及预后情况.结果 与IABP置入前比较,患者置入IABP后平均动脉压、心率、LVEF及心功能指标均得到不同程度的改善,无严重并发症出现,预后良好.结论 IABP辅助治疗急性心肌梗死合并心源性休克可能有效安全.%Objective To analyze clinical efficacy of intra-aortic balloon pump(IABP) counterpulsation in adjuvant treatment of patients with acute myocardial infarction(AMI) complicated with cardiogenic shock. Methods Fifty senile patients with AMI complicated with cardiogenic shock were chosen to observe the hemodynamic changes,the cardiac function,the IABP complication and prognosis before and after applying IABP. Results Compared with before applying IABP, hemodynamic parameters such as MAP,HR,LVEF and the cardiac function were improved in varying degrees after applying IABP,no serious complication appeared and prognosis was good. ConclusionIABP for adjuvant treatment of AMI complicated with cardiogenic shock is safe and effective.

  9. Assessment of the "long sheath" technique for percutaneous aortic balloon valvuloplasty.

    Science.gov (United States)

    Plante, S; Beatt, K J; van den Brand, M; Di Mario, C; Meier, B; Serruys, P W

    1990-02-01

    A 100 cm-long 16.5 F valvuloplasty catheter introducer was assessed as an adjunct for percutaneous transluminal aortic valvuloplasty (PTAV) via the femoral artery in 31 patients with severe aortic stenosis. Observed improvements in peak systolic gradient (81.6 +/- 29.9 mm Hg vs. 35.5 +/- 16.0 mm Hg, P less than 0.000001) and aortic valve area (0.6 +/- 0.4 cm2 vs. 1.0 +/- 0.6 cm2, P less than 0.00001) were similar to those achieved in a control group (C) of 17 patients in which no femoral sheath was used. However, a shorter procedure duration (211 +/- 81 min vs. 117 +/- 30 min, P less than 0.001) and a reduced rate of vascular complications at the femoral puncture site (41% vs. 6.5%) were observed in patients in whom the long sheath (LS) technique was used. The frequency of other PTAV-related complications was comparable (C = 35%, LS = 29%, P = n.s.). Other technical advantages of this device are: 1) prevention of looping and bending of the balloon catheter in tortuous vessels and easy positioning of the balloon across the aortic orifice provided by the LS trackability, 2) stabilisation of the balloon during inflation, 3) monitoring of supravalvular aortic pressure provided by the side-arm of the LS and reliable measurement of systolic gradient, and 4) the ability to perform aortograms without the need of another catheter in the ascending aorta. Thus, in our experience, the long sheath technique is a valuable adjunct for PTAV. PMID:2306775

  10. Newly Shaped Intra-Aortic Balloons Improve the Performance of Counterpulsation at the Semirecumbent Position: An In Vitro Study.

    Science.gov (United States)

    Kolyva, Christina; Pepper, John R; Khir, Ashraf W

    2016-08-01

    The major hemodynamic benefits of intra-aortic balloon pump (IABP) counterpulsation are augmentation in diastolic aortic pressure (Paug ) during inflation, and decrease in end-diastolic aortic pressure (ΔedP) during deflation. When the patient is nursed in the semirecumbent position these benefits are diminished. Attempts to change the shape of the IAB in order to limit or prevent this deterioration have been scarce. The aim of the present study was to investigate the hemodynamic performance of six new IAB shapes, and compare it to that of a traditional cylindrical IAB. A mock circulation system, featuring an artificial left ventricle and an aortic model with 11 branches and physiological resistance and compliance, was used to test one cylindrical and six newly shaped IABs at angles 0, 10, 20, 30, and 40°. Pressure was measured continuously at the aortic root during 1:1 and 1:4 IABP support. Shape 2 was found to consistently achieve, in terms of absolute magnitude, larger ΔedP at angles than the cylindrical IAB. Although ΔedP was gradually diminished with angle, it did so to a lesser degree than the cylindrical IAB; this diminishment was only 53% (with frequency 1:1) and 40% (with frequency 1:4) of that of the cylindrical IAB, when angle increased from 0 to 40°. During inflation Shape 1 displayed a more stable behavior with increasing angle compared to the cylindrical IAB; with an increase in angle from 0 to 40°, diastolic aortic pressure augmentation dropped only by 45% (with frequency 1:1) and by 33% (with frequency 1:4) of the drop reached with the cylindrical IAB. After compensating for differences in nominal IAB volume, Shape 1 generally achieved higher Paug over most angles. Newly shaped IABs could allow for IABP therapy to become more efficient for patients nursed at the semirecumbent position. The findings promote the idea of personalized rather than generalized patient therapy for the achievement of higher IABP therapeutic efficiency, with a choice

  11. Newly Shaped Intra‐Aortic Balloons Improve the Performance of Counterpulsation at the Semirecumbent Position: An In Vitro Study

    Science.gov (United States)

    Kolyva, Christina; Pepper, John R.

    2016-01-01

    Abstract The major hemodynamic benefits of intra‐aortic balloon pump (IABP) counterpulsation are augmentation in diastolic aortic pressure (P aug) during inflation, and decrease in end‐diastolic aortic pressure (ΔedP) during deflation. When the patient is nursed in the semirecumbent position these benefits are diminished. Attempts to change the shape of the IAB in order to limit or prevent this deterioration have been scarce. The aim of the present study was to investigate the hemodynamic performance of six new IAB shapes, and compare it to that of a traditional cylindrical IAB. A mock circulation system, featuring an artificial left ventricle and an aortic model with 11 branches and physiological resistance and compliance, was used to test one cylindrical and six newly shaped IABs at angles 0, 10, 20, 30, and 40°. Pressure was measured continuously at the aortic root during 1:1 and 1:4 IABP support. Shape 2 was found to consistently achieve, in terms of absolute magnitude, larger ΔedP at angles than the cylindrical IAB. Although ΔedP was gradually diminished with angle, it did so to a lesser degree than the cylindrical IAB; this diminishment was only 53% (with frequency 1:1) and 40% (with frequency 1:4) of that of the cylindrical IAB, when angle increased from 0 to 40°. During inflation Shape 1 displayed a more stable behavior with increasing angle compared to the cylindrical IAB; with an increase in angle from 0 to 40°, diastolic aortic pressure augmentation dropped only by 45% (with frequency 1:1) and by 33% (with frequency 1:4) of the drop reached with the cylindrical IAB. After compensating for differences in nominal IAB volume, Shape 1 generally achieved higher P aug over most angles. Newly shaped IABs could allow for IABP therapy to become more efficient for patients nursed at the semirecumbent position. The findings promote the idea of personalized rather than generalized patient therapy for the achievement of higher IABP therapeutic efficiency

  12. Newly Shaped Intra-Aortic Balloons Improve the Performance of Counterpulsation at the Semirecumbent Position: An In Vitro Study.

    Science.gov (United States)

    Kolyva, Christina; Pepper, John R; Khir, Ashraf W

    2016-08-01

    The major hemodynamic benefits of intra-aortic balloon pump (IABP) counterpulsation are augmentation in diastolic aortic pressure (Paug ) during inflation, and decrease in end-diastolic aortic pressure (ΔedP) during deflation. When the patient is nursed in the semirecumbent position these benefits are diminished. Attempts to change the shape of the IAB in order to limit or prevent this deterioration have been scarce. The aim of the present study was to investigate the hemodynamic performance of six new IAB shapes, and compare it to that of a traditional cylindrical IAB. A mock circulation system, featuring an artificial left ventricle and an aortic model with 11 branches and physiological resistance and compliance, was used to test one cylindrical and six newly shaped IABs at angles 0, 10, 20, 30, and 40°. Pressure was measured continuously at the aortic root during 1:1 and 1:4 IABP support. Shape 2 was found to consistently achieve, in terms of absolute magnitude, larger ΔedP at angles than the cylindrical IAB. Although ΔedP was gradually diminished with angle, it did so to a lesser degree than the cylindrical IAB; this diminishment was only 53% (with frequency 1:1) and 40% (with frequency 1:4) of that of the cylindrical IAB, when angle increased from 0 to 40°. During inflation Shape 1 displayed a more stable behavior with increasing angle compared to the cylindrical IAB; with an increase in angle from 0 to 40°, diastolic aortic pressure augmentation dropped only by 45% (with frequency 1:1) and by 33% (with frequency 1:4) of the drop reached with the cylindrical IAB. After compensating for differences in nominal IAB volume, Shape 1 generally achieved higher Paug over most angles. Newly shaped IABs could allow for IABP therapy to become more efficient for patients nursed at the semirecumbent position. The findings promote the idea of personalized rather than generalized patient therapy for the achievement of higher IABP therapeutic efficiency, with a choice

  13. Application of intra-aortic balloon pump in acute myocardial infarction complicated with cardiogenic shock%主动脉内球囊反搏在急性心肌梗死合并心源性休克中的应用

    Institute of Scientific and Technical Information of China (English)

    刘颖; 刘心甜; 沈菲; 智红; 王琳

    2013-01-01

    目的:探讨主动脉内球囊反搏(IABP)在急性心肌梗死(AMI)合并心源性休克中的应用价值.方法:收集88例AMI合并心源性休克患者的临床资料,其中50例行IABP,38例药物治疗,回顾性分析88例患者的治疗效果及安全性.结果:对于AMI并心源性休克患者,应用IABP后可改善血流动力学,使患者的收缩压、心率趋于稳定,左心室射血分数(LVEF)有明显改善,与非IABP组比较,差异有统计学意义(P<0.05);IABP组住院生存时间优于非IABP组(RR =0.402,95%CI:0.175 ~0.921,P=0.031).肢体缺血与出血的发生率2组无统计学差异(P>0.05).结论:对于AMI合并心源性休克的患者,行IABP辅助循环,可改善血流动力学,改善住院生存时间,且相对安全.%Objective:To evaluate the effect of intra-aortic balloon pump (IABP) in acute myocardial infarction (AMI) complicated with cardiogenic shock.Methods:Clinical data of 88 patients with AMI complicated with cardiogenic shock were collected,50 patients receiving IABP support while 38 patients receiving drug treatment.The therapeutic effect and safety were analyzed retrospectively.Results:Stabilization of patients'systolic blood pressure and heart rate,improvement of LVEF were found in IABP group and were more significant when compared with those without IABP (P < 0.05),and the survival time in hospital was superior in patients with IABP than those without IABP (RR =0.402,95% CI:0.175 ~0.921,P =0.031).The incidence of limb ischemia and bleeding showed no significant difference in two groups.Conclusions:IABP support can improve hemodynamic and the survival time in hospital for patients with AMI complicated with cardiogenic shock,and it is safe.

  14. Have we given up on intra-aortic balloon counterpulsation in post-myocardial infarction cardiogenic shock?

    Science.gov (United States)

    Acharji, Subasit; Mathur, Atish; Lakshmanadoss, Umashankar; Prasad, Hari; Singh, Maninder; Kaluski, Edo

    2013-11-01

    The recently published Intra-aortic Balloon Pump in Cardiogenic Shock II (IABP-SHOCK II) trial concluded that intra-aortic counterpulsation (IACP) does not reduce 30-day mortality in patients with cardiogenic shock (CS) complicating acute myocardial infarction (AMI) for whom early revascularization strategy was planned. The study resulted in downgrading IACP in post-AMI CS patients by certain professional organizations like the European Society of Cardiology. Although this is the largest and most important CS study of this decade, it suffers from considerable shortcomings: (1) time intervals from chest-pain onset or AMI recognition to revascularization, enrollment, and IACP initiation are not disclosed; (2) 86.6% of the treatment arm initiated IACP only post-percutaneous coronary intervention (PCI), and 4.3 % did not receive IACP at all; (3) 17.4% of the control arm crossed over to IACP or other mechanical support, mostly due to protocol violations; (4) there is no adjudication of the mortality events; (5) follow-up is limited to 30 days; and (5) both methodology (especially IACP device size) and quality of IACP are not evaluated and documented. Because the study assessed mostly the efficacy and safety of IACP initiated post-PCI, the study conclusions should not be extrapolated to IACP pre-PCI or during PCI in CS. Moreover, IACP had a favorable effect on the mortality of younger patients. Intra-aortic counterpulsation should remain the first line of mechanical circulatory support for the hemodynamically compromised AMI patients with or without CS who are undergoing primary PCI. Early upgrade to more advanced mechanical circulatory support should be considered for selective suitable candidates who remain in refractory CS despite revascularization and IACP.

  15. 急性心力衰竭应用主动脉内球囊反搏患者血小板减少因素分析%Cause analysis of thrombocytopenia in acute heart failure implanted with intra-aortic balloon pump

    Institute of Scientific and Technical Information of China (English)

    房芳; 李宇

    2016-01-01

    Objective To explore the causes of thrombocytopenia in acute heart failure (AHF) implanted with intra-aortic balloon pump (IABP).Methods Totally 50 cases with AHF implanted with IABP from November 2011 to November 2013 were retrospective enrolled.The time duration of IABP implantion and change of thrombocyte were recorded;the correlations of thrombocytopenia with disease type,size of ballon,gender were analyzed,the influence of thrombocytopenia on hospital mortality rate were assessed.Results The time duration of IABP implantion was (181 ±34) h (32.4-1 136.5 h).There was 27 patients with thrombocytopenia (mild:15 cases,moderate:9 cases,severe:3 cases),the time of the least platelet count was(100 ± 10) h.The incidence of thrombocytopenia in patients with acute myocardial infarction induced AHF was not significantly different from that in patients with other causes induced AHF [51.6% (16/31) vs 57.9% (11/19)] (P > 0.05).The incidence of thrombocytopenia was significantly lower in patients applied with 30 CC balloon than that in patients applied with 40 CC balloon [31.3% (5/16) vs 64.7% (22/34)],was significantly lower in males than that in femals [46.2% (18/39) vs 81.8% (9/11)] (P < 0.05).In 50 patients,17 cases was dead in hospital;the mortality rate in patients with thrombocytopenia was significantly higher than that in patients without thrombocytopenia [48.1% (13/27) vs 17.4% (4/23)] (P <0.05).Conclusion Thrombocytopenia can increase the morality rate in acute heartfailure patients implanted with IABP,which is correlated with the size of implanted balloon and gender.%目的 探讨急性心力衰竭应用主动脉内球囊反搏(IABP)患者血小板减少的原因.方法 回顾性选取首都医科大学附属北京安贞医院2011年11月至2013年11月收治的应用IABP的急性心力衰竭患者50例,记录应用IABP的时间以及应用后患者的血小板变化情况;分析血小板减少和疾病类型、球囊大小、性别的关

  16. Centrifugal pump support for distal aortic perfusion during repair of traumatic thoracic aortic injury.

    Science.gov (United States)

    Walls, Joseph T; Curtis, Jack J; McKenney-Knox, Charlotte A; Schmaltz, Richard A

    2002-11-01

    Paraplegia from ischemic injury of the spinal cord and renal failure from inadequate perfusion of the kidneys may occur from aortic cross-clamping during repair of traumatic thoracic aortic injuries. After Institutional Review Board approval, we retrospectively reviewed the charts of 26 patients surgically treated for traumatic transection of the descending thoracic aorta during a 14 year period (1987-2001), using centrifugal pump (Sarns) support for distal aortic perfusion. The study group comprised 19 males and 7 females, whose ages ranged from 15 to 69 years. For all but 1 patient, who fell from a flagpole, the injuries were incurred in motor vehicle accidents. Aortic cross-clamp time lasted between 5 to 78 min (median = 40 min). Mean arterial pressure ranged from 50 to 80 mm Hg (median = 70 mm Hg). All patients survived operation without developing paraplegia or renal failure. Distal centrifugal pump perfusion during repair of traumatic injury of the descending thoracic aorta is a valuable adjunct during surgical treatment and aids in preservation of spinal cord and renal function.

  17. Patients With Small Left Ventricular Size Undergoing Balloon Aortic Valvuloplasty Have Worse Intraprocedural Outcomes

    Science.gov (United States)

    Don, Creighton; Gupta, Pritha P.; Witzke, Christian; Kesarwani, Manoj; Cubeddu, Roberto J.; Inglessis, Ignacio; Palacios, Igor F.

    2014-01-01

    Objectives To evaluate the impact of left ventricular (LV) chamber size on procedural and hospital outcomes of patients undergoing aortic valvuloplasty. Background Balloon aortic valvuloplasty (BAV) is used as an integral step during transcatheter aortic valve implantation. Patients with small, thickened ventricles are thought to have more complications during and following BAV. Methods Retrospective study of consecutive patients with severe, symptomatic calcific aortic stenosis who underwent retrograde BAV at Massachusetts General Hospital. We compared patients with left ventricular end-diastolic diameters (LVEDD) <4.0 cm (n = 31) to those with LVEDD ≥4.0 cm (n = 78). Baseline and procedural characteristics as well as clinical outcomes were compared. Multivariate logistic regression was used for the adjusted analysis. Results Patients with smaller LV chamber size were mostly women (80.7% vs. 19.4%, P < 0.01) and had a smaller body surface area (BSA), (1.61 ± 0.20 m2 vs. 1.79 ± 0.25 m2, P < 0.01). Patients with smaller LV chamber size had higher ejection fractions and thicker ventricles. Otherwise, baseline characteristics were similar. The intraprocedural composite of death, cardiopulmonary arrest, intubation, hemodynamic collapse, and tamponade was higher for patients with LVEDD < 4.0 cm (32.3% v. 11.5%, P = 0.01). Adjusting for age, gender, BSA, LV pressure, and New York Heart Association class, LVEDD < 4.0 cm remained an independent predictor of procedural (OR 5.1, 95% CI 1.4– 18.2) and in-hospital complications (OR 3.8, 95% CI 1.2–11.6). Conclusions Compared to patients undergoing BAV with LVEDD ≥4.0 cm, those with smaller LV chambers had worse procedural and in-hospital outcomes. PMID:22926957

  18. 急性大面积ST段抬高型心肌梗死患者早期床旁应用主动脉内气囊反搏术预后观察%Observation on the prognosis of early application of bedside intra-aortic balloon pump counterpulsation in patients with acute ST-segment elevation myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    李志娟; 李春燕; 董平栓; 杨旭明; 刘威; 王可; 李治国; 赵玉伟; 靳国青; 李转珍

    2012-01-01

    目的:研究急性大面积ST段抬高型心肌梗死(STEMI)患者在择期经皮冠状动脉介入治疗(PCI)前尽早床旁应用主动脉内气囊反搏术(IABP)对预后的观察.方法:选取发病12 ~72 h的STEMI患者150例,随机分为2组,IABP组72例,对照组78例,2组均给予规范的药物治疗,IABP组同时床旁应用IABP.2组均于发病10~14d行冠脉造影,必要时行PCI术,评价梗死相关血管PCI术前及术后冠脉血流,术后4周心功能、IABP主要不良心脏事件的发生情况.结果:2组患者PCI术前TIMI血流、PCI术后4周主要不良心脏事件的发生率、左心室射血分数(LVEF)均有显著性差异(P<0.05).结论:对于急性大面积STEMI患者择期行PCI,尽早床旁应用IABP能改善梗死相关血管的TIMI血流,改善心功能,减少主要不良心脏事件的发生率,临床应用安全可行.%Objective: To evaluate the effect of early application of intra-aortic balloon pump counterpulsation (IABP) on prognosis of patients with acute ST-segment elevation myocardial infarction (STEMI) before elective percutaneous coronary interventional (PCI). Methods; One hundred and fifty patients with STEMI were randomly divided into two groups: 72 patients in IABP group and 78 in control group. All patients in IABP group receiving bedside IABP support treatment while patients in control group do not. All patients were performed PCI after 10 to 14 days. The blood flow rate of infart related coronary vessel was observed before and after PCI. The major adverse cardiac events ( MACE) and heart function at 4 weeks were studied. Results; In IABP group, blood flow rate of related coronary vessel, the occurance of MACE at 4 weeks, left ventricle ejection fraction (LVEF) were significant different in two groups (P < 0. 05). Conclusions; Early application of IABP for patients with STEMI before elective PCI is safe and effective, which can reduce the incidence of MACE, and improve heart function.

  19. 急性心肌梗死并心源性休克患者早期主动脉内球囊反搏联合急诊介入的疗效观察%Effect of early intra-aortic balloon pumping support combined emergency intervention in patients of acute myocardial infarction complicated with cardiac Shock

    Institute of Scientific and Technical Information of China (English)

    裘毅钢; 李田昌; 陈宇; 李贤峰; 曹毅; 田海涛; 李东韬

    2014-01-01

    目的:探讨早期主动脉内球囊反搏(IABP)植入在急性心肌梗死(AMI)合并心源性休克(CS)患者救治中的价值。方法140例主动脉内球囊反搏联合急诊经皮管状动脉介入治疗(PCI)治疗的AMI合并CS患者,按照发生CS至IABP入的时间,分为:A组为CS至IABP辅助治疗时间<3 h,B组为>3 h;观察指标为靶血管、冠脉病变情况等,并记录总IABP辅助时间,死亡、急性呼吸衰竭、急性肾功能衰竭等临床事件。结果两组间基线情况、靶血管病变、静脉用药等无统计学差异;A组三支病变比率、无复流发生率低于B组,但无统计学差异;A组总IABP辅助时间、全因病死率低于B组,有统计学差异,P<0.05;A组心源性死亡、急性呼吸发生率、急性肾衰发生率均低于B组,但无统计学差异。结论在AMI合并CS的患者尽早应用IABP联合血运重建可能有助于改善生存率。%Objective To investigate the effect of early Intra-aortic balloon pumping (IABP) support combined emergency intervention in patients of acute myocardial infarction (AMI) complicated with cardiac Shock (CS). Methods Clinical data of AMI complicated with cardiac shock in 140 cases of IABP combine with emergency percutaneous coronary intervention (PCI) admitted in Navy General Hospital of the PLA in between January 2011 and December 2012 were collected and divided into two groups according to the time from CS to IABP. The time interval in group A (n=61) was less than 3 hours and group B (n=79) were more than 3 hours. The target coronary artery, the number of culprit vessel, the total time of IABP treatment, hospital mortality, acute respiratory failure, acute renal failure were observed. Results No statistical significance in the rates of triple vessel disease, no-reflow, cardiogenic death, acute respiratory failure and acute renal failure was found between the two groups even although they all reflected lower in

  20. 急性心肌梗死患者主动脉内球囊反搏术后下呼吸道感染风险及与预后关系%Risk factors for lower respiratory tract infection and its relation to prognosis in patients with acute myocardial infarction received intra-aortic balloon pump counterpulsation

    Institute of Scientific and Technical Information of China (English)

    谢江; 牛丽丽; 崔俊玉; 谭琛

    2012-01-01

    Objective:To explore the risk factors for lower respiratory tract infection in patients with acute myo-cardial infarction (AMI) complicated with cardiogenic shock treated by intra-aortic balloon pump (IABP) counterpul-sation,as well as its effect on prognosis. Methods:The risk factors for lower respiratory tract infection in 55 patients with AMI complicated with cardiogenic shock receiving IABP were analyzed logistically,and the effect of infection on prognosis was evaluated. Results: With treatment of IABP,43. 6% of the patients developed lower respiratory tract infection. The chance of developing the infection was higher in patients experienced invasive ventilation, blood transfusion, deep vein catheterization and lack of prophylactic use of antibiotics (P<0. 05). The mortality was higher in patients with infection than those without infection (75. 0% vs 38. 7%,P=0. 007). Cardiogenic shock, septic shock and multiple organ dysfunction syndrome were the main causes of death for patients with infections. Conclusion; Invasive ventilation, deep vein catheterization and blood transfusion are positively associated with lower respiratory tract infection, while prophylactic administration of antibiotics may reduce respiratory tract infections.%目的:探讨主动脉内球囊反搏(IABP)救治的急性心肌梗死(AMI)心源性休克患者发生下呼吸道感染的危险因素及对预后的影响.方法:回顾55例接受IABP治疗的AMI心源性休克患者,Logistic回归分析住院期间下呼吸道感染的危险因素,评估感染对预后的影响.结果:43.6% IABP治疗的AMI心源性休克患者发生下呼吸道感染,有创机械通气、输血(血液制品)、未预防性使用抗生素、深静脉置管者发生感染的机会比较大(P<0.05).感染患者病死率明显高于非感染者(75.0% vs 38.7%,P=0.007);心源性休克、感染性休克和多器官功能不全是下呼吸道感染患者主要的死因.结论:下呼吸道感染与有创通气

  1. Intraluminal Projection of Descending Thoracic Aorta and Intraaortic Balloon Pump Catheter Examined by Transesophageal Echocardiography in Patients Undergoing Coronary Artery Bypass Surgery

    OpenAIRE

    Orihashi, Kazumasa; Oka, Yasu

    1991-01-01

    The thoracic descending aorta (DTA) was examined in 57 patients undergoing coronary artery bypass grafting (41 men and 16 women: 63.0 ± 10.6 years old) using two-dimensional transesophageal echocardiography. An intraaortic balloon pump (IABP) was instituted in ten patients. A short-axis view of DTA was examined for intraluminal projection from the diaphragm level to the aortic arch level. In a frozen-frame image, the area and the height of the projection at each clockwise direction was measur...

  2. Balloon aortic valvuloplasty as a bridge-to-decision in high risk patients with aortic stenosis: a new paradigm for the heart team decision making

    Science.gov (United States)

    Saia, Francesco; Moretti, Carolina; Dall'Ara, Gianni; Ciuca, Cristina; Taglieri, Nevio; Berardini, Alessandra; Gallo, Pamela; Cannizzo, Marina; Chiarabelli, Matteo; Ramponi, Niccolò; Taffani, Linda; Bacchi-Reggiani, Maria Letizia; Marrozzini, Cinzia; Rapezzi, Claudio; Marzocchi, Antonio

    2016-01-01

    Background Whilst the majority of the patients with severe aortic stenosis can be directly addressed to surgical aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI), in some instances additional information may be needed to complete the diagnostic workout. We evaluated the role of balloon aortic valvuloplasty (BAV) as a bridge-to-decision (BTD) in selected high-risk patients. Methods Between 2007 and 2012, the heart team in our Institution required BTD BAV in 202 patients. Very low left ventricular ejection fraction, mitral regurgitation grade ≥ 3, frailty, hemodynamic instability, serious comorbidity, or a combination of these factors were the main drivers for this strategy. We evaluated how BAV influenced the final treatment strategy in the whole patient group and in each specific subgroup. Results Mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) was 23.5% ± 15.3%, age 81 ± 7 years. In-hospital mortality was 4.5%, cerebrovascular accident 1% and overall vascular complications 4% (0.5% major; 3.5% minor). Of the 193 patients with BTD BAV who survived and received a second heart team evaluation, 72.6% were finally deemed eligible for definitive treatment (25.4% for AVR; 47.2% for TAVI): 96.7% of patients with left ventricular ejection fraction recovery; 70.5% of patients with mitral regurgitation reduction; 75.7% of patients who underwent BAV in clinical hemodynamic instability; 69.2% of frail patients and 68% of patients who presented serious comorbidities. Conclusions Balloon aortic valvuloplasty can be considered as bridge-to-decision in high-risk patients with severe aortic stenosis who cannot be immediate candidates for definitive transcatheter or surgical treatment. PMID:27582761

  3. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    Energy Technology Data Exchange (ETDEWEB)

    Fetterly, K; Mathew, V [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

  4. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    International Nuclear Information System (INIS)

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors

  5. Factors influencing outcomes of intra-aortic balloon counterpulsation in elderly patients

    Institute of Scientific and Technical Information of China (English)

    WU Xue-ping; LIU Hong-wei; ZHAO Xiao-ning; CAO Jian; ZHU Ping

    2013-01-01

    Background Intra-aortic balloon counterpulsation (IABP) is a mechanical cardiac-assist device that is used for cardiac support.There are no published reports about the use of IABP in eldedy Chinese patients,especially for those over 80 years old.The aim of this study was to describe the clinical outcomes,influencing factors,and complications in patients ≥80 years old and requiring IABP.Methods We performed a retrospective study of 134 consecutive patients who received IABP therapy.Based on age,we defined two groups; those ≥80 years old and those <80 years old.Results The overall mortality was 41.8%.Patients ≥80 years old had higher mortality rates than those <80 years old (47.9% vs.30.2%).Patients ≥80 years old had fewer successful revascularizations (45.8%) and more pulmonary infections(47.9%) than patients <80 years old (60.3% and 30.2%,respectively); these differences were statistically significant.The most common non-cardiac complication was pulmonary infection.Cardiogenic shock and pulmonary infection were risk factors for all-cause,in-hospital mortality,whereas revascularization success was a negative risk factor for the ≥80 years old patients.Conclusions IABP may be successfully and safely employed in patients ≥80 years old,having severe heart disease,with few complications.Patients ≥80 years old who need IABP therapy are less likely to have a successful revascularization and are more likely to develop pulmonary infections than patients <80 years old.

  6. Interventional treatment of common congenital heart diseases: the common view of Chinese medical experts. Part Four: Percutaneous balloon valvuloplasty for pulmonary and aortic valve stenosis

    International Nuclear Information System (INIS)

    Percutaneous balloon valvuloplasty has become the treatment of first choice for pulmonary valve stenosis. Congenital aortic valve stenosis can also be relieved by percutaneous balloon dilatation. Percutaneous valvuloplasty is indicated for patients with isolated pulmonary valve stenosis when the transvalvular peak systolic pressure gradient is over 40 mmHg and for patients with aortic valve stenosis when the pressure gradient exceeds 60 mmHg. A careful selection of patients, standardized procedure, individualized selection of the balloon type, size and length, and careful avoidance of any damage to chorda tendineae and to surrounding tissue are keys to achieving a successful procedure. Balloon valvuloplasty should be selectively performed in new-born and in infant since complications of the procedure are inversely related to age. (authors)

  7. Controlled transient respiratory arrest along with rapid right ventricular pacing for improving balloon stability during balloon valvuloplasty in pediatric patients with congenital aortic stenosis - A retrospective case series analysis

    Directory of Open Access Journals (Sweden)

    Gupta Sampa

    2010-01-01

    Full Text Available Rapid right ventricular pacing is safe, effective, and established method to provide balloon stability during balloon aortic valvuloplasty (BAV. Controlled transient respiratory arrest at this point of time may further reduce left ventricular stroke volume, providing an additional benefit to maintain balloon stability. Two groups were studied. Among the 10 patients, five had rapid pacing alone (Group A, while the other five were provided with cessation of positive pressure breathing as well (Group B. The outcomes of BAV in the two groups of patients were studied. One patient in Group A had failed balloon dilatation even after the fourth attempt, while in Group B there were no failures. The peak systolic gradient reduction was higher in Group B (70.05% in comparison to 52.16% of group A. In Group A, five subjects developed aortic regurgitation (grade 2 in four and grade 3 in one, while no grade 3 aortic regurgitation developed in any patient in Group B. Controlled transient respiratory arrest along with rapid ventricular pacing may be effective in maintaining balloon stability and improve the outcome of BAV.

  8. Controlled transient respiratory arrest along with rapid right ventricular pacing for improving balloon stability during balloon valvuloplasty in pediatric patients with congenital aortic stenosis--a retrospective case series analysis.

    Science.gov (United States)

    Gupta, Sampa Dutta; Das, Soumi; Ghose, Tapas; Sarkar, Achyut; Goswami, Anupam; Kundu, Sudeshna

    2010-01-01

    Rapid right ventricular pacing is safe, effective, and established method to provide balloon stability during balloon aortic valvuloplasty (BAV). Controlled transient respiratory arrest at this point of time may further reduce left ventricular stroke volume, providing an additional benefit to maintain balloon stability. Two groups were studied. Among the 10 patients, five had rapid pacing alone (Group A), while the other five were provided with cessation of positive pressure breathing as well (Group B). The outcomes of BAV in the two groups of patients were studied. One patient in Group A had failed balloon dilatation even after the fourth attempt, while in Group B there were no failures. The peak systolic gradient reduction was higher in Group B (70.05% in comparison to 52.16% of group A). In Group A, five subjects developed aortic regurgitation (grade 2 in four and grade 3 in one, while no grade 3 aortic regurgitation developed in any patient in Group B). Controlled transient respiratory arrest along with rapid ventricular pacing may be effective in maintaining balloon stability and improve the outcome of BAV. PMID:20826965

  9. Assessment of the "long sheath" technique for percutaneous aortic balloon valvuloplasty

    NARCIS (Netherlands)

    S. Plante (Sylvain); K.J. Beatt (Kevin); M.J.B.M. van den Brand (Marcel); C. di Mario (Carlo); B. Meier (Bernard); P.W.J.C. Serruys (Patrick)

    1990-01-01

    textabstractA 100 cm-long 16.5 F valvuloplasty catheter introducer was assessed as an adjunct for percutaneous transluminal aortic valvuloplasty (PTAV) via the femoral artery in 31 patients with severe aortic stenosis. Observed improvements in peak systolic gradient (81.6 +/- 29.9 mm Hg vs. 35.5 +/-

  10. Sarns centrifugal pump for repair of thoracic aortic injury: case reports.

    Science.gov (United States)

    Walls, J T; Curtis, J J; Boley, T

    1989-09-01

    A new centrifugal pump (Sarns), originally designed for ventricular assist, was successfully used in two patients during repair of traumatic pseudoaneurysm of the descending thoracic aorta. The distal thoracic aorta was perfused without heparinization to avoid spinal cord and visceral ischemia, reduce afterload on the heart, and avoid clamp injury to the aorta. Distal mean aortic pressure was maintained above 50 mm Hg with a mean pump flow of 1.75 liter/minute. Proposed structural advantages of the Sarns centrifugal pump for perfusion of the distal thoracic aorta without heparin are resistance to thrombus formation, air embolus, and hemolysis.

  11. A High Performance Pulsatile Pump for Aortic Flow Experiments in 3-Dimensional Models.

    Science.gov (United States)

    Chaudhury, Rafeed A; Atlasman, Victor; Pathangey, Girish; Pracht, Nicholas; Adrian, Ronald J; Frakes, David H

    2016-06-01

    Aortic pathologies such as coarctation, dissection, and aneurysm represent a particularly emergent class of cardiovascular diseases. Computational simulations of aortic flows are growing increasingly important as tools for gaining understanding of these pathologies, as well as for planning their surgical repair. In vitro experiments are required to validate the simulations against real world data, and the experiments require a pulsatile flow pump system that can provide physiologic flow conditions characteristic of the aorta. We designed a newly capable piston-based pulsatile flow pump system that can generate high volume flow rates (850 mL/s), replicate physiologic waveforms, and pump high viscosity fluids against large impedances. The system is also compatible with a broad range of fluid types, and is operable in magnetic resonance imaging environments. Performance of the system was validated using image processing-based analysis of piston motion as well as particle image velocimetry. The new system represents a more capable pumping solution for aortic flow experiments than other available designs, and can be manufactured at a relatively low cost. PMID:26983961

  12. [Perioperative management of abdominal aortic balloon occlusion in patients complicated with placenta percteta: a case report].

    Science.gov (United States)

    Zeng, Hong; Wang, Yan; Wang, Yang; Guo, Xiang-yang

    2015-12-18

    When placenta previa complicated with placenta percreta, the exposure of operative field is difficult and the routine methods are difficult to effectively control the bleeding, even causing life-threatening results. A 31-year-old woman, who had been diagnosed with a complete type of placenta previa and placenta percreta with bladder invasion at 34 weeks gestation. Her ultrasound results showed a complete type of placenta previa and there was a loss of the decidual interface between the placenta and the myometrium on the lower part of the uterus, suggestive of placenta increta. For further evaluation of the placenta, pelvis magnetic resonance imaging was performed, which revealed findings suspicious of a placenta percreta. She underwent elective cecarean section at 36 weeks of gestation. Firstly, two ureteral stents were placed into the bilateral ureter through the cystoscope. After the infrarenal abdominal aorta catheter was inserted via the femoral artery (9 F sheath ), subarachnoid anesthesia had been established. A healthy 2 510 g infant was delivered, with Apgar scores of 10 at 1 min and 10 at 5 min. Immediately after the baby was delivered, following which there was massive haemorrhage and general anaesthesia was induced. The balloon catheter was immediately inflated until the wave of dorsal artery disappeared. With the placenta retained within the uterus, a total hysterectomy was performed. The occluding time was 30 min. The intraoperative blood loss was 2 500 mL. The occluding balloon was deflated at the end of the operation. The patient had stable vital signs and normal laboratory findings during the recovery period and the hemoglobin was 116 g/L. She was discharged six days after delivery without intervention-related complications. This case illustrates that temporary occlusion of the infrarenal abdominal aorta using balloon might be a safe and effective treatment option for patients with placenta previa complicated with placenta percreta, who were at high

  13. Laceration of anterior mitral leaflet postpercutaneous balloon mitral valvuloplasty for rheumatic mitral stenosis

    OpenAIRE

    Jadoon, Mehmood; Roberts, M. J.; Dixon, L.; Jones, Mark

    2012-01-01

    A 37-year-old Caucasian female with known rheumatic mitral stenosis was admitted for Balloon mitral valvuloplasty which was complicated with a laceration of anterior mitral leaflet (A2 scallop) resulting in severe mitral regurgitation. Intra-aortic balloon pump (IABP) was instituted and the patient was referred for emergency mitral surgery. During surgery anterior mitral leaflet was excised. Most of the posterior leaflet was preserved. Mitral valve was replaced with St Jude mitral mechanical ...

  14. PUCA pump and IABP comparison : analysis of hemodynamic and energetic effects using a digital computer model of the circulation

    NARCIS (Netherlands)

    Fresiello, Libera; Gu, Y. John; Ferrari, Gianfranco; Di Molfetta, Arianna; Rakhorst, Gerhard

    2011-01-01

    The pulsatile catheter pump (PUCA pump) is a left ventricular assist device that provides additional flow to the left ventricle. It is usually run in order to ensure a counterpulsation effect, as in the case of the intra-aortic balloon pump (IABP). Because of this similarity, a comparison between th

  15. World-first implantable aortic valvo-pump (IAVP) with sufficient haemodynamic capacity.

    Science.gov (United States)

    Qian, K X; Wang, D F; Topaz, S; Zeng, P; Ru, W M; Yuan, H Y; Zwischenberg, J B

    2005-01-01

    For better anatomic and physiologic fitting, a novel implantable aortic valvo-pump (IAVP) has been developed. A valvo-pump is a micro axial flow impeller pump, which has the same dimensions and function, as well as the same location, of a valve. Therefore, IAVP needs no inlet and outlet tubes, no additional anatomic occupation, and has less physiologic disturbance to natural circulation compared with the traditional bypass left ventricular assist device (LVAD). The device has a stator and a rotor. The stator consists of a motor coil with an iron core and an outflow guide vane; the rotor includes driven magnets and impeller. There is neither bearing nor strut in both the pump and the motor. In order to reduce the attractive force between the rotor and the stator, so as to enhance the durability of the performance, the rotor magnets were minimized without reducing the driving torque and efficiency of the motor. The impeller vane was designed according to a three-dimensional and analytical method, for preventing stasis and turbulence. The largest outer diameter is 24.7 mm and the length at this point is 12.4 mm. The total weight is 40 g (including the rotor of 11 g). The consumed power is 7 W (14 V x 0.5 A) at 15 000 rpm. This rotating speed stays unchanged during haemodynamic testing together with a pulsatile centrifugal pump, which imitates a failing ventricle. The maximal flow cross IAVP reaches over 10 l min(-1) and the pressure head at 0 l min(-1) can be as large as 80 mmHg. At flow rate of 4 - 8 l min(-1), IAVP enlarges the flow c. 1 l min(-1) and meanwhile increases the pressure about 10 mmHg. The pressure pulsatility generated by the pulsatile centrifugal pump remains 40 mmHg after passing IAVP. By first animal experimental trial the device was sewed in aortic position of an 80 kg pig without harm to adjacent tissue and organs. IAVP promises to be a viable alternative to natural donor heart for heart transplantation in the future.

  16. Initial hydrodynamic study on a new intraaortic axial flow pump: Dynamic aortic valve

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Rotary blood pumps have been researched as implantableventricular assist devices for years. To further reduce the complex of implanted axial pumps, the authors proposed a new concept of intraaortic axial pump, termed previously as "dynamic aortic valve (DAV)". Instead of being driven by an intraaortic micro-electric motor, it was powered by a magnetic field from outside of body. To ensure the perfusion of coronary artery, the axial flow pump is to be implanted in the position of aortic valve. It could serve as either a blood pump or a mechanical valve depending on the power input. This research tested the feasibility of the new concept in model study. A column, made from permanent magnet, is jointed to an impeller in a concentric way to form a "rotor-impeller". Supported by a hanging shaft cantilevered in the center of a rigid cage, the rotor-impeller can be turned by the magnetic field in the surrounding space. In the present prototype, the rotor is 8 mm in diameter and 15 mm in length, the impeller has 3 vanes with an outer diameter of 18 mm. The supporting cage is 22 mm in outer diameter and 20 mm in length. When tested, the DAV prototype is inserted into the tube of a mock circuit. The alternative magnetic field is produced by a rotating magnet placed side by side with the rotor-impeller at a distance of 30 mm. Once the alternative magnetic field is presented in the surrounding space, the DAV starts to turn, leading to a pressure difference and liquid flow in the tube. The flow rate or pressure difference is proportioned to rotary speed. At the maximal output of hydraulic power, the flow rate reached 5 L/min against an afterload of 100 mmHg. The maximal pressure difference generated by DAV at a rotation rate of 12600 r/min was 147 mmHg. The preliminary results demonstrated the feasibility of "DAV", further research on this concept is justifiable.

  17. DISPOSABLE NON-MECHANICAL ELASTOMERIC BALLOON PUMP FOR CONTINUOUS EPIDURAL INFUSION: AN EFFECTIVE AND RELIABLE MEANS FOR POSTOPERATIVE ANALGESIA

    Directory of Open Access Journals (Sweden)

    Dilip Kumar

    2016-01-01

    Full Text Available Postoperative pain an unpleasant sensory and emotional experience is one of the most challenging and gratifying domains to treat. Aim is here to assess effectiveness of postoperative pain relief, side effects and complications while using non-mechanical disposable elastomeric pump as continuous epidural infusion. PATIENTS AND METHODS The present study has been carried out on thirty patients in postoperative wards. At the end of operation the Elastomeric pump containing 125ml of bupivacaine (0.125% was connected with the epidural catheter Pain was assessed by VAS scoring system ranging from 0 to 10. Haemodynamic parameters, quality of analgesia, degree of motor block, and adverse effect encountered were recorded at two hours interval for 24 hours at the end of two hours of subarachnoid block when operation is over. RESULTS AND OBSERVATIONS None of our patients had shown any clinically significant changes in their cardiorespiratory indices in the postoperative period. All the patients at 0 hr. were having VAS score of 0 and till 22 hours enjoyed good pain relief, i.e. VAS of 3-4. Infusion is not always steady as set by the manufacturer. There is no motor blockade after 16 hours (Bromage-0. Insignificant number of patients experienced nausea or vomiting and backache. CONCLUSIONS Elastomeric balloon pumps is a reliable device to deliver LA agents steadily and safely with 0.125% bupivacaine as continuous epidural.

  18. Buddy balloon for TAVI.

    Science.gov (United States)

    Balkin, Jonathan; Silberman, Shuli; Almagor, Yaron

    2013-11-15

    Percutaneous transfemoral aortic valve replacement is a new rapidly evolving technique that has made significant progress in recent years. The technology is however limitted and in some cases has resulted in failure to deliver the prosthetic valve. We describe a new technique using a buddy balloon, from the contralateral femoral artery, to assist in crossing the native aortic valve in those cases where extreme calcification and or tortuosity have caused the delivery system to hang up on the aortic wall. The technique is easily applied and facilitates the success of the procedure in cases which may otherwise have to be converted to open surgical aortic valve replacement.

  19. Initial hydrodynamic study on a new intraaortic axial flow pump: Dynamic aortic valve

    Institute of Scientific and Technical Information of China (English)

    LI; Guorong

    2001-01-01

    [1]Portner, P. M., Oyer, P. E., Pennington, D. G. et al., Implantable electrical left ventricular assist system: bridge to trans-plantation and the future, Ann. Thorac. Surg., 1989, 47: 142.[2]Pennington, D. G., McBride, L. R. et al., Bridging to heart transplantation with circulatory support devices, J. Heart Transplant, 1989, 8: 116.[3]Westaby, S., Katsumata, T., Evans, R. et al., The Jarvik 2000 Oxford system: increasing the scope of mechanical circulatory support, J. Thorac. Cardiovasc. Surg., 1997, 114: 467.[4]Thomas, D. C., Butler, K. C., Taylor, L. P. et al., Progress on development of the Nimbus-University of Pittsburgh axial flow left ventricular assist system, ASAIO J., 1998, 44: M521.[5]Levin, H. R., Oz, M. C., Paker, M. et al., Reversal of chronic ventricular dilation in patients with end stage cardiomyopathy by prolonged mechanical unloading, Circulation, 1995, 91: 2717.[6]Frazier, O. H., Benedict, C. R., Radovancevic, B. et al., Improved left ventricular function after chronic left ventricular offloading, Ann. Thorac. Surg., 1996, 62: 675.[7]Li, G. R., Zhu, X. D., Wang, J. H. et al., China Patent, Publication Number: 1168263, 1997.[8]Li, G. R., Zhu, X. D., Hu, S. S. et al., Preliminary study of a new concept for left ventricular assistance Dynamic Aortic Valve, J. Biomed. Eng. (in Chinese), 1999, 16(1): 116.[9]Lee, W. H. Jr., Krumbhaar, D., Fonkalstrud, E. W. et al., Denaturation of plasma proteins as a cause of morbidity and death after intracardiac operations, Surgery, 1961, 50: 29.[10] Kalter, R. D., Saul, C. M., Wetstein, L. et al., Cardiopulmonary bypass associated hemostalic abnormalities, J. Thorac. Cardiovasc. Surg., 1979, 77: 427.[11] Ross, J. Jr., Braunwald, E., The study of left ventricular function in man by increasing resistance to ventricular ejection with angiotensin, Circulation, 1964, 29: 739.[12] Mitamura, Y., Yozu, R., Tanka, T. Y. et al., Toward an implantable axial intracardiac blood

  20. Percutaneous Balloon Angioplasty for Severe Native Aortic Coarctation in Young Infants Less Than 6 Months: Medium-to Long-term Follow-up

    Institute of Scientific and Technical Information of China (English)

    Lan He; Fang Liu; Lin Wu; Chun-Hua Qi; Li-Feng Zhang; Guo-Ying Huang

    2015-01-01

    Background:Although balloon angioplasty (BA) has been performed for more than 20 years,its use as a treatment for native coarctation of the aorta (CoA) during childhood,especially in young infants,remains controversial.This study aimed to assess the effects and potential role of percutaneous transcatheter BA for native CoA as an alternative therapy to surgical repair in young infants.Methods:The 37 patients aged from 6 days to 6 months with severe CoA in congestive heart failure or circulatory shock were admitted for BA.Patient's weight ranged from 2.4 to 6.1 kg.All 37 patients were experiencing cardiac dysfunction,and eight patients were in cardiac shock with severe metabolic acidosis.Eleven patients had an isolated CoA,whereas the others had a CoA associated with other cardiac malformations.Cardiac catheterization and aortic angiography were performed under general anesthesia with intubation.Transfemoral arterial approaches were used for the BA.The size of the balloon ranged from 3 mm × 20 mm to 8 mm × 20 mm,and a coronary artery balloon catheter was preferred over a regular peripheral vascular balloon catheter.Results:The femoral artery was successfully punctured in all but one patient,with that patient undergoing a carotid artery puncture.The systolic peak pressure gradient (PG) across the coarctation was 41.0 ± 16.0 mmHg (range 13-76 mmHg).The mean diameter of the narrowest coarctation site was 1.7 ± 0.6 mm (range 0.5-2.8 mm).All patients had successful dilation;the PG significantly decreased to 13.0 ± 1 1.0 mmHg (range 0-40 mmHg),and the diameter of coarctation significantly improved to 3.8 ± 0.9 mm (range 2.5-5.3 mm).No intraoperative complications occurred for any patients.However,in one case that underwent a carotid artery puncture,a giant aneurysm formed at the puncture site and required surgical repair.The following observations were made during the follow-up period from 6-month to 7-year:(1) The PG across the coarctation measured by

  1. A two years outcome analysis of patients on intra-aortic balloon pump in a tertiary care center

    Directory of Open Access Journals (Sweden)

    Bajan K

    2004-01-01

    Full Text Available AIMS: To analyze data of patients with IABP insertion with respect to severity of illness, complications and outcome. MATERIALS AND METHODS: A retrospective study conducted on 70 patients over 2 years. Patients were divided into Group 1, emergent insertion and Group 2, elective insertion. They were further analyzed for degree of cardiac dysfunction [ventricular performance assessed by 2-D echocardiography and dose of inotropes required], location [Intensive Care Unit (ICU, Operating Room (OR or Cath lab] and occurrence of complications [thrombocytopenia, worsening renal parameters, and thrombo-embolic phenomena]. RESULTS: 29 patients underwent emergent insertion and 41 patients had elective insertion. Indications were cardiogenic shock- 24 (34.28% patients; pulmonary edema 7 (10% patients; peri-operatively 29 (41.42%patients; and for cath lab support 10 (14%patients. Most of the patients were also on inotropes: dopamine=48(82.75%, epinephrine=40(68.96%, norepinephrine=7(12.06% and dobutamine=6(10.34%. Common complications noted were thrombocytopenia in 41 patients and azotemia in 30 patients. Three patients (37.5% required embolectomy and one later needed an amputation. Twenty three patients died . The mortality rate was highest in patients with an ejection fraction < 20% (71.42%. Mean duration of IABP was 60 hours. CONCLUSIONS: IABP was an effective tool for circulatory support for a range of indications.

  2. Subsidiary therapeutic efficacy of balloon pump support in rescuing patients with cardiogenic shock%球囊反搏术在心源性休克患者抢救中的辅助作用

    Institute of Scientific and Technical Information of China (English)

    侯毅; 马友妮

    2013-01-01

    目的 评价主动脉内球囊反搏术(IABP)在急性心肌梗死合并心源性休克患者抢救中的辅助作用.方法 将同一时期在我院进行抢救的72例急性心肌梗死合并心源性休克患者按照是否行急诊IABP循环支持治疗分为IABP组(36例)和对照组(36例),两组均行经皮冠状动脉介入治疗及常规用药治疗;比较两组患者术后1周、4周、3个月主要心血管不良事件(MACE)的发生率及术后1周的左心室功能.结果 两组患者术后的左心室功能和MACE发生率存在差异,IABP组术后1周的左心室功能明显优于对照组[(42.6±8.1)%vs(39.8±7.9)%,P<0.05],IABP组1周、4周和3个月的死亡率均低于对照组(30.6% vs 55.6%,38.9% vs 63.9%,47.2% vs 75.0%,均P<0.05).结论 主动脉内球囊反搏术在急性心肌梗死合并心源性休克患者抢救中能有效改善患者左心室功能及减少主要心血管不良事件的发生率,有效改善心源性休克患者的预后.%Objective To assess the subsidiary therapeutic efficacy of intra-aortic balloon pump (IABP) support in rescuing patients with acute myocardial infarction (AMI) complicated by cardiogenic shock (CS).Methods Thirty-six patients receiving emergency PCI with IABP support were enrolled as the IABP group,and 36 patients receiving emergency PCI without IABP support at the same time were selected as the control group.The rates of major adverse cardiac events (MACE) were evaluated in the two groups one week,4 weeks and 3 months after the operation,respectively.The left ventricular function was also evaluated.Results There was significant difference in the left ventricular function and the rates of MACE between the two groups.The left ventricular function in the first week of the IABP group was better than that in the control group [(42.6±8.1)% vs (39.8±7.9)%,P<0.05],and the mortality rates in the first week,the forth week and the third month of the LABP group were lower than those

  3. Emergency Abdominal Aortic Aneurysm Repair in a Patient with Failing Heart: Axillofemoral Bypass Using a Centrifugal Pump Combined with Levosimendan for Inotropic Support

    Directory of Open Access Journals (Sweden)

    Pavel Michalek

    2011-01-01

    Full Text Available We describe the case of an 83-year-old patient requiring repair of a large symptomatic abdominal aortic aneurysm (AAA. The patient was known to have coronary artery disease (CAD with symptoms and signs of significant myocardial dysfunction, left-heart failure, and severe aortic insufficiency. The procedure was performed with the help of both mechanical and pharmacological circulatory support. Distal perfusion was provided by an axillofemoral bypass with a centrifugal pump, with dobutamine and levosimendan administered as pharmacological inotropic support. The patient's hemodynamic status was monitored with continuous cardiac output monitoring and transesophageal echocardiography. No serious circulatory complications were recorded during the perioperative and postoperative periods. This paper suggests a potential novel approach to combined circulatory support in patients with heart failure, scheduled for open abdominal aortic aneurysm repair.

  4. Valve-in-valve implantation with a 23-mm balloon-expandable transcatheter heart valve for the treatment of a 19-mm stentless bioprosthesis severe aortic regurgitation using a strategy of "extreme" underfilling.

    Science.gov (United States)

    Chevalier, Florent; Leipsic, Jonathon; Généreux, Philippe

    2014-09-01

    We report a case of valve-in-valve (ViV) implantation by transfemoral approach with a 23-mm balloon-expandable prosthesis inside a stentless 19-mm acutely degenerated bioprosthesis, using a strategy of "extreme" underfilling. A 74-year-old patient presented to our institution in cardiogenic shock. An initial transesophageal echocardiography (TEE) showed severe central aortic regurgitation (AR) due to a torn leaflet. She was deemed inoperable and considered for urgent transcatheter aortic valve replacement. Given the fairly small true internal diameter, a strategy of 3-cc underfilling of a 23-mm transcatheter heart valve (THV) was planned. However, the final implantation was performed with 5-cc underfilling due to the incapacity to deliver the entire amount of fluid contained in the inflation syringe. TEE guidance confirmed the successful positioning and deployment of the prosthesis, with no AR and a mean gradient of 25 mm Hg. While implantation of a smaller prosthesis (20 mm) was debated during the Heart Team discussion, the risk of valve embolization due to inadequate anchoring inside the stentless prosthesis led to the selection of a 23-mm THV. At 6-month follow-up, the patient was in NYHA class I, with no AR and a mean gradient of 28 mm Hg. We report for the first time the use of in vivo THV with 5-cc underfilling with no acute or short-term structural failure, and the first ViV implantation by transfemoral approach with a 23-mm balloon-expandable prosthesis inside a stentless 19-mm bioprosthesis. The current report presents the challenges related to ViV implantation inside a small stentless bioprosthesis and offers practical ways to overcome them. © 2014 Wiley Periodicals, Inc.

  5. DISPOSABLE NON-MECHANICAL ELASTOMERIC BALLOON PUMP FOR CONTINUOUS EPIDURAL INFUSION: AN EFFECTIVE AND RELIABLE MEANS FOR POSTOPERATIVE ANALGESIA

    OpenAIRE

    Dilip Kumar; Mrinal Kanti; Subhankar

    2016-01-01

    Postoperative pain an unpleasant sensory and emotional experience is one of the most challenging and gratifying domains to treat. Aim is here to assess effectiveness of postoperative pain relief, side effects and complications while using non-mechanical disposable elastomeric pump as continuous epidural infusion. PATIENTS AND METHODS The present study has been carried out on thirty patients in postoperative wards. At the end of operation the Elastomeric pump containin...

  6. Comparison of transient changes in renal function between off-pump and on-pump coronary artery bypass grafting

    Institute of Scientific and Technical Information of China (English)

    ZHANG Wen-feng; GU Tian-xiang; DIAO Cheng; ZHANG Yu-hai; WANG Chun; FANG Qin; WANG Hai-long

    2008-01-01

    Background Acute renal failure following coronary artery bypass grafting(CABG)surgery is associated with high morbidity and mortality.Approximately half of all patients who develop acute kidney injury(AKI)subsequently develop acute renal failure(ARF).The purpose of the study was to compare early transient changes in renal function within the first post-operative week following CABG in patients that were either off-pump or on-pump.Methods Eight hundred and forty-nine consecutive patients with isolated CABG in a single institution between January 1990 and August 2006 were retrospectively analyzed.including 51 8 off-pump and 331 on-pump patients.A multivariate Logistic regression model was constructed to identify risk factors for the development of AKI.Results sixty-one off-pump patients and 63 on-pump patients developed AKI.Risk factors for the development of post-operative AKI included an ejection fraction≥50%or≤30%,a pulse pressure>60 mmHg,peripheral vascular disease,diabetes,emergent procedure,triple-vessel disease,body mass index,peri-operative and post-operative.intra.aortic balloon pumping,NYHA class III and IV,and cardiopulmonary bypass.An ejection fraction Z50%and peri-operative and post-operative intra-aortic balloon pumping were protective(OR<1).Peak serum creatinine for post-operative Akl was noted 12 hours and 24 hours in the off-pump and on-pump patients,respectively.Serum creatinine kinetics revealed rapid recovery in the 24th to 48th hour(off-pump)and the 48th to 72nd hour(on-pump).Conclusion Renal protection strategies are indicated from general anesthesia induction until 48 and 72 houm post-operatively in off-pump and on-pump patients,respectively.

  7. EFFECTS OF OUABAIN AND DIGOXIN ON THE GENE EXPRESSION OF SODIUM PUMP α-SUBUNIT ISOFORM IN AORTIC SMOOTH MUSCLE OF RATS

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective To compare the effects of ouabain and digoxin on both the systolic blood pressure and sodium pump α-subunit isoforms gene expression in the aortic smooth muscle of rats. Methods Normal SpragueDawley rats were injected with ouabain (20μg·kg-1 ·d-1 ,i. p),digoxin (32 μg·kg-1 ·d-1,i. p)and normal saline once a day, respectively, and indirect systolic blood pressure was recorded once a week. Six weeks later,all the rats were killed and sodium pump α1-,α2-,and α3-subunit mRNA levels were detected in the aortic smooth muscle with reverse transcription polymerase chain reaction(RT-PCR) method. Results The systolic blood pressure of rats infused with ouabain increased significantly at the end of week 6 [132. 6± 9. 0 mmHg (1 mmHg = 0. 133 kPa)vs 115. 7±8.2mmHg, P <0. 01] ,while no difference of blood pressure was found between digoxin group and NS group (P>0.05).The expression of sodium pump α-subunit isoforms in aortic smooth muscle was regulated by either ouabain or digoxin:both ouabain and digoxin increased α1- and α3-subunit expression, α2-subunit decreased in digoxin group but unchanged in ouabain group. Conclusion These results suggest that both ouabain and digoxin could regulate sodium pump α-subunit isoform expression, which might be related to the physiological roles of endogenous ouabain and might be responsible for the difference between the pharmacological and toxicological effects of ouabain and digoxin,including their effects on blood pressure.

  8. 新型带瓣膜主动脉瓣球囊扩张支架的研制及测试%A novel balloon-expandable valved stents for transcatheter aortic valve implantation: preparation and testing

    Institute of Scientific and Technical Information of China (English)

    陈翔; 谭洪文; 张志钢; 朱玉峰; 赵仙先; 秦永文; 马丽萍

    2013-01-01

    Objective To evaluate the functions of a new balloon-expandable valved stent for transcatheter aortic valve implantation and the delivery system,so as to provide evidence for future animal study.Methods A new tube-like balloonexpandable valved stent was designed and made of cobalt-base alloys.Bovine pericardium was sutured by hand into the stent to prepare valved aortic stent,which was placed on the instrument to test the pulsating flow and fatigue property of prosthetic valve.The valved stent,which was compressed on a balloon catheter and pulled into a delivery sheath,was placed in the native aortic valve of isolated goat heart via the ascending aorta,and water was injected into the ascending aorta by a silicon tube to evaluate the competence of the prosthetic heart valves.Results Plusating flow examination showed that the artificial valve opened and closed well,without noticeable reflow,and accorded with human physiology.The prosthetic heart valves also performed well in the testing of fatigue property.The valved stent could be stably placed in the native valves of goat heart by delivery sheath,and the prosthetic heart valves showed satisfactory function.Conclusion The aortic valved stent is welldesigned and has satisfactory function.It can be used for animal study of transcathetcr aortic valve implantation.%目的 通过体外测试评价新型带瓣膜主动脉瓣球囊扩张支架及输送装置的各项性能,为下一步动物体内实验提供依据.方法 支架材料采用钴基合金,设计成圆柱形网状结构.人工瓣膜取材于经处理的新鲜牛心包,将人工瓣膜缝合在支架上制成带瓣膜主动脉支架.使用人工心脏瓣膜脉动流测试仪和人工心脏瓣膜加速疲劳测试仪,分别对带瓣膜支架瓣叶材料脉动流和人工瓣膜耐疲劳情况进行测试.将带瓣膜支架压缩至自行研制的输送装置的球囊上,取离体羊心脏标本,经升主动脉将支架直视下置入

  9. Controlling methods of a newly developed extra aortic counter-pulsation device using shape memory alloy fibers.

    Science.gov (United States)

    Hashem, Mohamed O; Yamada, A; Tsuboko, Y; Muira, H; Homma, D; Shiraishi, Y; Yambe, T

    2013-01-01

    Diastolic counter-pulsation has been used to provide circulatory augmentation for short term cardiac support. The success of intra-aortic balloon pump (IABP) therapy has generated interest in long term counter-pulsation strategies to treat heart failure patients. The authors have been developing a totally implantable extra aortic pulsation device for the circulatory support of heart failure patients, using 150 µm Ni-Ti anisotropic shape memory alloy (SMA) fibers. These fibers contract by Joule heating with an electric current supply. The special features of our design are as follow: non blood contacting, extra aortic pulsation function synchronizing with the native heart, a wrapping mechanical structure for the aorta in order to achieve its assistance as the aortomyoplsty and the extra aortic balloon pump. The device consisted of rubber silicone wall plates, serially connected for radial contraction. We examined the contractile function of the device, as well as it controlling methods; the phase delay parameter and the pulse width modulation, in a systemic mock circulatory system, with a pneumatically driven silicone left ventricle model, arterial rubber tubing, a peripheral resistance unit, and a venous reservoir. The device was secured around the aortic tubing with a counter-pulsation mode of 1:4 against the heartbeat. Pressure and flow waveforms were measured at the aortic outflow, as well as its driving condition of the contraction phase width and the phase delay. The device achieved its variable phase control for co-pulsation or counter-pulsation modes by changing the phase delay of the SMA fibers. Peak diastolic pressure significantly augmented, mean flow increased (p<0.05) according to the pulse width modulation. Therefore the newly developed extra aortic counter-pulsation device using SMA fibers, through it controlling methods indicated its promising alternative extra aortic approach for non-blood contacting cardiovascular circulatory support.

  10. Application of intra-aortic balloon counterpulsation in patients with acute myocardial infarction complicated right heart failure%主动脉内球囊反搏在急性心肌梗死并右心衰竭中的应用

    Institute of Scientific and Technical Information of China (English)

    张治平; 刘成伟; 吴明祥; 许志勇; 杨遇春; 陈国洪; 苏晞

    2012-01-01

    目的:探讨主动脉内球囊反搏(IABP)在急性心肌梗死并右心衰竭中应用的价值.方法:69例急性心肌梗死并心源性休克行IABP辅助循环治疗患者中急性右心衰竭12例(17.4%),回顾性分析此12例患者临床资料,病人年龄(64.1±9.7)岁,IABP辅助循环治疗时间15~288 h,(95±76)h,9例(75%)行经皮冠状动脉介入术(PCI).结果:12例患者住院期间主要并发症包括:出血3例(25%),肢体缺血1例(8.3%),急性肾功能衰竭2例(16.7%),多器官功能衰竭1例(8.3%).1例死于多器官功能衰竭,其余11例(91.7%)成功撤除IABP辅助循环,病情好转出院.结论:急性心肌梗死并严重右心衰竭死亡率高,在常规治疗疗效不佳时,主动脉内球囊反搏辅助循环治疗可能有益.%Objective: To study application of intra-aortic balloon pump (IABP) in patients with acute myocardial infarction (AMI) complicated right heart failure. Methods: There were 12 (17. 4%) cases with acute right heart failure among 69 patients with AMI complicated cardiogenic shock undergoing IABP auxiliary circulation treatment, clinical data of the 12 patients were retrospectively analyzed. Mean age of the 12 patients was (64. 1 ± 9. 7) yearsold, duration of auxiliary circulation treatment with IABP was 15~288 (95 ± 76) h. And there were nine (75%) patients undergoing percutaneous coronary intervention (PCI). Results: Main complications of 12 patients during admission included bleeding (n = 3, 25%), limb ischemia (n= 1, 8.3%), acute renal failure (n = 2, 16. 7%) and multi - organ failure (n = 1, 8. 3%). Except one case died from multi-organ failure, IABP was successfully removed in other 11 (91. 7%) patients and their condition improved, all discharged from hospital. Conclusion: There is high mortality rate in acute myocardial infarction complicated severe right heart failure. Intra-aortic balloon pump may be beneficial for treatment when effect of routine therapy is poor.

  11. Off-Pump Coronary Bypass Grafting Causing Stunned Myocardium

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2015-10-01

    Full Text Available The term “stunned myocardium” refers to abnormalities in the myocardial function following reperfusion and is common in on-pump coronary artery bypass grafting (CABG and is exceedingly rare in off- pump CABG. A 53-year-old man presented with unstable angina due to the severe stenosis of the left anterior descending coronary artery (LAD and the obtuse marginal. Laboratory findings and Chest X-ray revealed nothing abnormal. The intraoperative course was uneventful. The patient left the operating room without any inotropic support. Six hours later, however, he developed low cardiac output .At exploration, cardiac tamponade was excluded and flowmetry showed that the graft had adequate function. Cardiac enzymes were normal. High-dose adrenalin and Dobutamine were administrated and an intra-aortic balloon pump was used. After hemodynamic stabilization, the patient left the Intensive Care Unit without an intra-aortic balloon pump and inotropic support. On the fifth postoperative day, coronary angiography showed patent grafts and correct anastomotic sites. On the seventh postoperative day, the akinetic lateral wall of the left ventricle changed to dyskinesia. Finally after hospital discharge on the thirtieth postoperative day, an echocardiogram showed normal left ventricular function without regional wall motion abnormalities

  12. Augmentation of abdominal organ perfusion during cardiopulmonary bypass with a novel intra-aortic pulsatile catheter pump

    NARCIS (Netherlands)

    Gu, YJ; De Kroon, T; Elstrodt, JM; van Oeveren, W; Boonstra, PW; Rakhorst, G

    2005-01-01

    Background: Current pulsatile pumps for cardiopulmonary bypass (CPB) are far from satisfactory because of the poor pulsatility. This study was undertaken to examine the efficiency of a novel pulsatile catheter pump on pulsatility and its effect on abdominal organ perfusion during CPB. Methods: Twelv

  13. Aortic insufficiency

    Science.gov (United States)

    ... Heart valve - aortic regurgitation; Valvular disease - aortic regurgitation; AI - aortic insufficiency ... BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: ...

  14. Influence of cardiogenic shock with or without the use of intra-aortic balloon pump on mortality in patients with ST-segment elevation myocardial infarction

    Directory of Open Access Journals (Sweden)

    Jesper Khedri Jensen

    2015-03-01

    Conclusion: Patients with STEMI and cardiogenic shock had substantial short- and long-term mortality that may be improved with IABP implantation. More studies on use of IABP in such patients are warranted.

  15. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars;

    2014-01-01

    BACKGROUND: Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES: This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS......: We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV. RESULTS: A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48...

  16. Navigation Technology in Endovascular Aortic Repair

    OpenAIRE

    Manstad-Hulaas, Frode

    2013-01-01

    A number of diseases can affect the aorta, and endovascular (minimally invasive) techniques can be used to treat many of these conditions. During endovascular aortic repair, different instruments, such as catheters (plastic tubes), metal wires and balloons are visualized by X-rays. Intermittent aortic injections of contrast medium improve the depiction of the aorta; however, contrast medium may damage kidney function in some patients, radiation can be harmful and X-ray images are 2- dimension...

  17. Vascular Rupture Caused by a Molding Balloon during Endovascular Aneurysm Repair: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Young; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo [Dept. of Radiology, Samsugn Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Young Wook; Kim, Dong Ik [Dept. of Surgery, Samsugn Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    Endovascular aneurysm repair (EVAR) has been accepted as an alternative to traditional open surgery in selected patients. Despite the minimally invasiveness of this treatment, several complications may occur during or after EVAR. Complications include endoleak, aortic dissection, distal embolism, or iatrogenic injury to the access artery. However, there are few reports on the vascular rupture caused by a molding balloon during EVAR. We report two cases of infrarenal abdominal aortic aneurysms complicated by procedure-related aortic or iliac artery rupture by the molding balloon during EVAR. In our cases, we observed suddenly abrupt increase of the diameter of the endograft during balloon inflation, because we inflated the balloon rapidly. In conclusion, careful attention must be paid during inflation of the molding balloon to prevent vascular rupture.

  18. Aortic Aneurysm

    Science.gov (United States)

    ... Most aneurysms are in the aorta, the main artery that runs from the heart through the chest and abdomen. There are two types of aortic aneurysm: Thoracic aortic aneurysms (TAA) - these occur in the part of the aorta running through the chest Abdominal aortic aneurysms (AAA) - these occur in the part ...

  19. Endovascular resection of the native aortic valve before transcatheter aortic valve implantation: state of the art and review.

    Science.gov (United States)

    Navarra, Emiliano; Mosala Nezhad, Zahra; Bollen, Xavier; Gielen, Charles-Edouard; Mastrobuoni, Stefano; De Kerchove, Laurent; Raucent, Benoit; Astarci, Parla

    2016-09-01

    Transcatheter aortic valve implantation was introduced into clinical practice in 2002 as a rescue approach in patients presenting with symptomatic severe aortic stenosis but not eligible for conventional aortic valve replacement. This technique allows implantation of a balloon expandable bioprosthesis without resection of the native aortic valve. Several complications are described as a consequence of the residual highly calcified valve being squeezed against the aortic wall by the stent of the implant. This can result in deformation of the metal stent and paravalvular leakage, risk of occlusion of the coronary ostia, or central and peripheral embolization of valvular debris. To avoid these complications, many authors suggest the possibility to resect and remove the native aortic valve before transcatheter aortic valve implantation. In this field, different authors have described possible techniques and different sources of energy to resect the calcified valve. In this article, we review the development of these experimental techniques and discuss future prospects in this field. PMID:27032472

  20. 主动脉球囊反搏联合机械通气治疗心源性休克的临床研究%CLINICAL RESEARCH ON INTRA AORTIC BALLOON COUNTERPULSATION COMBINED WITH MECHANICAL VENTILATION IN TREATMENT OF CARDIOGENIC SHOCK

    Institute of Scientific and Technical Information of China (English)

    王瑛

    2012-01-01

    [Objective] To investigate the aortic balloon counterpulsation combined with mechanical ventilation in treat-menl of acute myocardiaT infarction with cardiogenic shock. [Methods] From August 2010 to May 2011, 39 cases of acute myocardial infarction with cardiogenic shock in our department were treated, we combined aortic balloon counterpulsation and mechanical ventilation in their treatment, then retrospectively analyzed the clinical data of patients. [Results] 39 cases of a-cute myocardial infarction complicated by cardiogenic shock recovered and were discharged in 12 cases, the treatment efficiency was 30.8%; 27 vases died in the hospital, the mortality tale was 69.2%.Mean arterial pressure, arterial partial pressure of oxygen and pH of 12 recovered and discharged cases were significantly higher after treatment than those before treatment, but ceo- ■ tral venous pressure was significantly lower after treatment than that before treatment, with significant difference (P< 0.05).Tbe death causes of 27 patients included multiple organ failure in 16 cases, severe infection in 5 cases, ventricular septal perforation in 4 cases, papillary muscle rupture in 3 cases, left ventricular free wall rupture in 1 case. [Conclusion], The application of intra -aortic balloon counterpulsation combined with mechanical ventilation in treatment of acute myocardial infarction with cardiogenic shock has a certain effect, but the mortality rate is still high; multiple organ failure in acute myocardial infarction complicated by cardiogenic shock patients is the main cause of death.%[目的]探讨主动脉球囊反博联合机械通气治疗急性心肌梗死合并心源性休克的疗效.[方法] 2010年8月~2011年5月期间,某科共收治急性心肌梗死合并心源性休克患者39例,联合应用主动脉球囊反博与机械通气对他们进行治疗,现回顾分析上述患者的临床资料.[结果]① 39例急性心肌梗死合并心源性休克患者康复出院12

  1. The nursing of use breathing machine adjuvant therapy acute myocardial infarction complicated by cardiogenic shock after intra-aortic balloon counterpulsation.%主动脉球囊反搏术后应用呼吸机辅助治疗急性心肌梗死合并心源性休克患者的护理

    Institute of Scientific and Technical Information of China (English)

    李坚

    2012-01-01

    目的:探讨主动脉球囊反搏术后应用呼吸机辅助治疗急性心肌梗死合并心源性休克患者的效果及护理方法.方法:回顾分析我院21例急性心肌梗死合并心源性休克患者主动脉球囊反搏术后应用呼吸机辅助治疗的护理措施.结果:急性心肌梗死合并心源性休克患者经过积极的抢救治疗,16例患者好转出院,3例患者抢救无效死亡,2例患者家属签字放弃抢救,自动出院.救治成功率为76.19%.结论:急性心肌梗死患者应用主动脉球囊反搏治疗具有良好的近期疗效,及时使用呼吸机辅助治疗,给予积极有效的预防治疗护理措施,能降低死亡率,提高救治成功率,促进患者康复.%Objective: To investigate the effect and nursing method of use breathing machine adjuvant therapy acute myocardial infarction( AMI) complicated by cardiogenic shock after intra - aortic balloon counterpulsation( IABP ) . Methods: Retrospective analyzed the nursing measures of 21 cases of myocardial infarction( AMI ) complicated by cardiogenic shock patients use intra - aortic balloon counterpulsation and breathing machine adjuvant therapy. Results:The patient of acute myocardial infarction( AMI) complicated by cardiogenic shock after the emergency treatment, 16 cases were cured, 3 cases were dead. , 2cases were amel iorated. The successful rate of rescue was 76.19%. Conclusion:IABP therapy for acute myocardial infarction patients have a good short -term curative effect, cardigenic shock is the severe complications of acute myocardial infarction( AMI), there was high morbidity, timely treatment by breathing machine and actively adopted effective measures can reduced mortality rate and improve the success rate, and will promote the patient soon to be restored to health.

  2. In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump.

    Science.gov (United States)

    Herreros, Jesús; Ubilla, Matías; Berjano, Enrique J; Vila-Nuñez, Juan E; Páramo, José A; Sola, Josu; Mercé, Salvador

    2010-02-01

    The aim of this study was to assess platelet dysfunction and damage to organs after extracorporeal circulation using a pump based on a new method that adds a pulsatile flow to the continuous flow provided by a centrifugal pump. The continuous component of the total flow (2-3 L/min) is created by a Bio-Pump centrifugal pump, while the pulsatile component is created by the pulsating of an inner membrane pneumatically controlled by an intra-aortic counterpulsation balloon console (systolic volume of 37.5 mL in an asynchronous way with a frequency of 60 bpm). Six pigs were subjected to a partial cardiopulmonary bypass lasting 180 min and were sacrificed 60 min after extracorporeal circulation was suspended. The hematological study included the measurement of hematocrit, hemoglobin, leukocytes, and platelet function. The new pump did not significantly alter either platelet count or platelet function. In contrast, hematocrit and hemoglobin were significantly reduced during extracorporeal circulation (approximately 5% P = 0.011, and 2 g/dL P = 0.01, respectively). The leukocyte count during extracorporeal circulation showed a tendency to decrease, but this was not significant. In general, the short-term use of the new pump (4 h) did not cause any serious morphological damage to the heart, lung, kidney, or liver. The results suggest that the hemodynamic performance of the new pump is similar to a conventional centrifugal pump and could therefore be appropriate for use in extracorporeal circulation.

  3. Aortic stenting.

    Science.gov (United States)

    Droc, Ionel; Calinescu, Francisca Blanca; Droc, Gabriela; Blaj, Catalin; Dammrau, Rolf

    2015-01-01

    The approach to aortic pathology is nowadays more and more endovascular at both thoracic and abdominal levels. Thoracic stenting has gained worldwide acceptance as first intention to treat pathologies of the descending thoracic aorta. Indications have been extended to aortic arch aneurysms and also to diseases of the ascending aorta. The current devices in use for thoracic endovascular repair (TEVAR) are Medtronic Valiant, Gore TAG, Cook Tx2 and Jotec. The choice of the endograft depends on the thoracic aortic pathology and the anatomical suitability. The technological evolution of the abdominal aortic endografts was very rapid, arriving now at the fourth generation. We report the results of 55 elective cases of endovascular abdominal aortic repair (EVAR) performed in two vascular surgical centers in Romania and Germany. The prostheses used were 16 E-vita Abdominal XT, 12 Excluder, eight Talent, seven PowerLink, three Endurant and nine custom-made, fenestrated or branched from Jotec. The mean follow-up was 18 months with CT-scan, duplex ultrasound and contrast-enhanced ultrasound. The mortality was 2%. EVAR tends to become the gold standard for abdominal aortic aneurysm repair. Technological development of the devices with lowest profile introduction systems will permit to extend the anatomical indications to new frontiers. PMID:26200430

  4. Validation of a protocol to assist patients with intra-aortic balloon Validación de un protocolo para la asistencia a pacientes con balón intraaórtico Validação de protocolo paraassistênciaa pacientes com balão intra-aórtico

    Directory of Open Access Journals (Sweden)

    Regimar Carla Machado

    2012-01-01

    Full Text Available OBJECTIVE: To develop a protocol of care for patients with Intra-Aortic Balloon and validate the content of this protocol. METHODS: Study of quantitative and descriptive approach. The methodology followed three steps: development of the instrument; content validity and reliability verification of the protocol for the analysis of agreement between specialists with greater experience. The study included 48 specialists, including physicians and nurses experienced in patient care in use of balloon. Items considered valid achieved at least 75% of consensus before the analysis of agreement between evaluators. RESULTS: We evaluated 36 items, of these, 20 were considered valid. The reliability was also verified, using consistency of the responses of more experienced evaluators. Among the items submitted to new statistical analysis by these evaluators, only two were considered valid. CONCLUSION: Based on the content validation, a protocol with 22 items concerning patient care without the use of intra-aortic balloon was developed.OBJETIVOS: Elaborar un protocolo de cuidados a pacientes con Balón Intraaórtico y validar el contenido de ese protocolo. MÉTODOS: Estudio de abordaje cuantitativo, descriptivo. La trayectoria metodológica siguió tres etapas: elaboración del instrumento; validación del contenido y verificación de la confiabilidad del protocolo por el análisis de concordancia entre peritos con mayor tiempo de experiencia. Participaron en el estudio 48 peritos, entre médicos y enfermeros, con experiencia en asistencia al paciente en uso del balón. Los items considerados válidos obtuvieron consenso mínimo del 75% frente al análisis de concordancia entre los evaluadores. RESULTADOS: Fueron evaluados 36 items, de éstos, 20 fueron considerados válidos. Se verificó también la confiabilidad, utilizando la congruencia de las respuestas de los evaluadores más experientes. De los items sometidos al nuevo análisis estadístico por esos

  5. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  6. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  7. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  8. Bursting water balloons

    CERN Document Server

    Lund, Hugh M

    2011-01-01

    The impact and rupture of water-filled balloons upon a flat, rigid surface is studied experimentally, for which three distinct stages of the flow are observed. Due to the impact, waves are formed on the balloon's surface for which the restoring force is tension in the latex. Immediately following rupture of the membrane, a shear instability created by the retraction of the balloon is observed. At later times, a larger-scale growth of the interfacial amplitude is observed, that may be regarded as a manifestation of a phenomenon known as the Richtmyer-Meshkov instability. This flow is closely related to the classical understanding of the Richtmyer-Meshkov instability for when there exists a density difference between the fluids inside and outside the balloon. Further, it is shown experimentally that this growth of the interface may also occur when there is no density difference across the balloon, a situation that does not arise for the standard Richtmyer-Meshkov instability.

  9. [Aortic aneurysm].

    Science.gov (United States)

    Villar, Fernando; Pedro-Botet, Juan; Vila, Ramón; Lahoz, Carlos

    2013-01-01

    Aortic aneurysm is one important cause of death in our country. The prevalence of abdominal aortic aneurism (AAA) is around 5% for men older than 50 years of age. Some factors are associated with increased risk for AAA: age, hypertension, hypercholesterolemia, cardiovascular disease and, in particular, smoking. The medical management of patients with an AAA includes cardiovascular risk treatment, particularly smoking cessation. Most of major societies guidelines recommend ultrasonography screening for AAA in men aged 65 to 75 years who have ever smoked because it leads to decreased AAA-specific mortality. PMID:24238836

  10. Balloon Design Software

    Science.gov (United States)

    Farley, Rodger

    2007-01-01

    PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.

  11. The Descending Helium Balloon

    Science.gov (United States)

    Helseth, Lars Egil

    2014-01-01

    I describe a simple and fascinating experiment wherein helium leaks out of a rubber balloon, thereby causing it to descend. An estimate of the volumetric leakage rate is made by measuring its rate of descent.

  12. A system for visualization and automatic placement of the endoclamp balloon catheter

    NARCIS (Netherlands)

    Furtado, H.; Stüdeli, T.; Sette, M.; Samset, E.; Gersak, B.

    2010-01-01

    The European research network "Augmented Reality in Surgery" (ARIS*ER) developed a system that supports minimally invasive cardiac surgery based on augmented reality (AR) technology. The system supports the surgical team during aortic endoclamping where a balloon catheter has to be positioned and ke

  13. Apical ballooning syndrome complicated by acute severe mitral regurgitation with left ventricular outflow obstruction – Case report

    Directory of Open Access Journals (Sweden)

    Celermajer David S

    2007-02-01

    Full Text Available Abstract Background Apical ballooning syndrome (or Takotsubo cardiomyopathy is a syndrome of transient left ventricular apical ballooning. Although first described in Japanese patients, it is now well reported in the Caucasian population. The syndrome mimicks an acute myocardial infarction but is characterised by the absence of obstructive coronary disease. We describe a serious and poorly understood complication of Takotsubo cardiomyopathy. Case Presentation We present the case of a 65 year-old lady referred to us from a rural hospital where she was treated with thrombolytic therapy for a presumed acute anterior myocardial infarction. Four hours after thrombolysis she developed acute pulmonary oedema and a new systolic murmur. It was presumed she had acute mitral regurgitation secondary to a ruptured papillary muscle, ischaemic dysfunction or an acute ventricular septal defect. Echocardiogram revealed severe mitral regurgitation, left ventricular apical ballooning, and systolic anterior motion of the mitral valve with significant left ventricular outflow tract gradient (60–70 mmHg. Coronary angiography revealed no obstructive coronary lesions. She had an intra-aortic balloon pump inserted with no improvement in her parlous haemodynamic state. We elected to replace her mitral valve to correct the outflow tract gradient and mitral regurgitation. Intra-operatively the mitral valve was mildly myxomatous but there were no structural abnormalities. She had a mechanical mitral valve replacement with a 29 mm St Jude valve. Post-operatively, her left ventricular outflow obstruction resolved and ventricular function returned to normal over the subsequent 10 days. She recovered well. Conclusion This case represents a serious and poorly understood association of Takotsubo cardiomyopathy with acute pulmonary oedema, severe mitral regurgitaton and systolic anterior motion of the mitral valve with significant left ventricular outflow tract obstruction. The

  14. Universal stratospheric balloon gradiometer

    Science.gov (United States)

    Tsvetkov, Yury; Filippov, Sergey; Brekhov, Oleg; Nikolaev, Nikolay

    The study of the interior structure of the Earth and laws of its evolution is one of the most difficult problems of natural science. Among the geophysical fields the anomaly magnetic field is one of the most informational in questions of the Earth’s crust structure. Many important parameters of an environment are expedient for measuring at lower altitudes, than satellite ones. So, one of the alternatives is stratospheric balloon survey. The balloon flight altitudes cover the range from 20 to 50 km. At such altitudes there are steady zone air flows due to which the balloon flight trajectories can be of any direction, including round-the-world (round-the-pole). For investigation of Earth's magnetic field one of the examples of such sounding system have been designed, developed and maintained at IZMIRAN and MAI during already about 25 years. This system consists of three instrumental containers uniformly placed along a vertical 6 km line. Up today this set has been used only for geomagnetic purposes. So we describe this system on example of the measuring of the geomagnetic field gradient. System allows measuring a module and vertical gradient of the geomagnetic field along the whole flight trajectory and so one’s name is - stratospheric balloon magnetic gradiometer (SMBG). The GPS-receivers, located in each instrumental container, fix the flight coordinates to within several tens meters. Process of SBMG deployment, feature of the exit of rope from the magazine at the moment of balloon launching has been studied. Used magazine is cellular type. The hodograph of the measuring base of SBMG and the technique of correction of the deviations of the measuring base from the vertical line (introduction of the amendments for the deviation) during the flight have been investigated. It is shown that estimation of the normal level of values of the vertical gradient of the geomagnetic field is determined by the accuracy of determining the length of the measuring base SBMG

  15. Mars Solar Balloon Lander Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  16. Venus Altitude Cycling Balloon Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ISTAR Group ( IG) and team mate Thin Red Line Aerospace (TRLA) propose a Venus altitude cycling balloon (Venus ACB), an innovative superpressure balloon...

  17. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik;

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI...

  18. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  19. 主动脉球囊反搏术治疗急性心肌梗死并心源性休克的疗效观察%Aortic Balloon Pump Treatment of Acute Myocardial Infarction and Cardiogenic Shock Efficacy

    Institute of Scientific and Technical Information of China (English)

    邹琼辉; 新怡康; 马伟东

    2013-01-01

    Objective:To explore the application value of IABP combined with cardiogenic shock patients in the treatment of AMI.Method:Clinical data of patients with AMI complicated with cardiogenic shock in 25 cases with IABP in our hospital from 2011 January to 2012 December were treated in Department of Cardiology under the support of emergency PCI treatment.Patients after diagnosis,given all patients in the IABP placement in the cardiac catheterization laboratory,and coronary angiography,and interventional therapy.Result:All the patients after treatment,the clinical symptoms disappeared,blood pressure,heart rate,urine volume than before treatment was obviously improved,compared with preoperative,postoperative, results had significant difference(P<0.05),2 patients with postoperative complication,after symptomatic treatment improved,2 patients died,clinical efficiency was 92%.Conclusion:As far as possible application of IABP treatment should be conclusion patients with AMI complicated with cardiogenic shock.%  目的:探讨IABP术在AMI合并心源性休克患者救治中的应用价值。方法:选择笔者所在医院自2011年1月-2012年12月心内科收治的25例应用IABP支持下行急症PCI治疗的AMI合并心源性休克患者的临床资料。患者确诊后,给予全部患者于心导管室行IABP置入术,再行冠状动脉造影术,及介入治疗。结果:全部患者经治疗后,临床症状逐渐消失,血压、心率、尿量等均较治疗前得到明显改善,术前、术后对比,差异有统计学意义(P<0.05),2例患者术后合并并发症,经对症治疗后得到好转,2例患者死亡,临床有效率为92%。结论:AMI合并心源性休克患者应尽量应用IABP治疗。

  20. Transcatheter Aortic Valve Implantation Experience with SAPIEN 3.

    Science.gov (United States)

    Ohno, Y; Tamburino, C; Barbanti, M

    2015-06-01

    Based on randomized trials with first generation devices, transcatheter aortic valve replacement (TAVI) has been included into the treatment strategy for high-risk and inoperable patients with severe aortic stenosis. Procedural complications remain a concern with TAVI, including stroke, vascular complications, paravalvular leak (PVL) and conduction disturbances. Addressing these limitations will support TAVI use in lower risk populations. This review discussed features and most recent clinical evidence of the new balloon-expandable THV (SAPIEN 3, Edwards Lifescience, Irvine, CA, USA). PMID:25900559

  1. On-Pump Beating Coronary Artery Bypass in High Risk Coronary Patients

    Directory of Open Access Journals (Sweden)

    Abbas Afrasiabirad

    2015-01-01

    Full Text Available Background: There are some conflicting results with Conventional Coronary Artery Bypass Grafts (CCABG with arrested heart in coronary high-risk patients. Moreover, performing off-pump CABG in these cases may be associated with serious complications. The objective of this study is to evaluate the efficacy of the on-pump beating CABG (OPBCABG in coronary high-risk patients in comparison with the conventional methods. Methods: In a prospective research study, 3000 off-pump CABG patients were considered during June 2003 to December 2011. Among these, 157 patients with one or more of the following risk factors were included for OPBCABG; severe left main stenosis, early post-acute myocardial infarction with ongoing chest pain, unstable angina, intractable ventricular arrhythmia, post complicated coronary intervention and severe left ventricular dysfunction. These patients were compared with 157 similar patients undergone CCABG with aortic cross clamp before 2003. Results: Preoperative patient characteristics revealed no significant differences between the two groups. The patients’ mean age and number of grafts were 57 years and 3 per patient respectively. Hospital mortality was 3.2% and 9% in OPBCABG and CCABG groups, respectively (P<0.001. Preoperative myocardial infarction, requirement of inotropic agents and intraaortic balloon pump, renal dysfunction and prolonged ventilation time were significantly higher in CCABG group. Conclusion: Our results suggest that OPBCABG is effective in coronary high-risk patients and significantly reduces mortality and the incidence of perioperative MI and other major complications.

  2. The future of transcatheter aortic valve implantation.

    Science.gov (United States)

    Hamm, Christian W; Arsalan, Mani; Mack, Michael J

    2016-03-01

    Since the introduction of transcatheter aortic valve implantation (TAVI) into clinical practice, the treatment of aortic stenosis has changed dramatically. In the past, medical therapy with or without balloon aortic valvuloplasty was the only option for inoperable patients. More recently, TAVI has become the treatment of choice for these patients and the preferred alternative for high-risk operable patients. Surgical aortic valve replacement (SAVR) currently remains the gold standard for patients at low or intermediate operative risk. As randomized trials have demonstrated comparable results between TAVI and SAVR in the high-risk population, there is now a clear trend towards performing TAVI even in intermediate-risk patients while awaiting the results of randomized trials in that population. Nevertheless, there are still questions regarding TAVI involving paravalvular leak (PVL), stroke, pacemaker requirements, and durability that remain to be more definitively answered before TAVI can routinely be performed in a broader, lower risk population. Improvements in patient selection, imaging, and second and third generation devices have decreased the incidence of PVLs and vascular complications that followed the earliest TAVI procedures, but the rates of perioperative stroke and permanent pacemaker implantation must still be addressed. Furthermore, the long-term durability of TAVI devices and a role for post-procedure antithrombotic management remain unanswered. Until these questions are more clearly answered, it is the Heart Team's task to determine the optimal treatment for each patient based on risk scores, frailty metrics, comorbidities, patient preference, and potential for improvement in quality of life.

  3. Aortic Annular Enlargement during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Selman Dumani

    2016-09-01

    Full Text Available In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.

  4. Aortic Aneurysm Statistics

    Science.gov (United States)

    ... connective tissue disorders, such as Marfan syndrome and Ehlers-Danlos syndrome, get thoracic aortic aneurysms. Signs and symptoms of thoracic aortic aneurysm can include Sharp, sudden pain in the chest or upper back. Shortness of ...

  5. Aortic aneurysm repair - endovascular

    Science.gov (United States)

    EVAR; Endovascular aneurysm repair - aorta; AAA repair - endovascular; Repair - aortic aneurysm - endovascular ... Endovascular aortic repair is done because your aneurysm is very large, growing quickly, or is leaking or bleeding. You may have ...

  6. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... to become you to our live webcast. Today we’re going to repair an abdominal aortic aneurysm ... and together as a team of multidisciplinary physicians, we’re going to repair an abdominal aortic aneurysm ...

  7. Aortic growth rates in chronic aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, A.M. [Department of Radiology, Division of Thoracic Radiology, University of Michigan Medical Center (United States)]. E-mail: ainekell@med.umich.edu; Quint, L.E. [Department of Radiology, Division of Thoracic Radiology, University of Michigan Medical Center (United States); Nan, B. [School of Public Health, University of Michigan, Ann Arbor, Michigan (United States); Zheng, J. [School of Public Health, University of Michigan, Ann Arbor, Michigan (United States); Cronin, P. [Department of Radiology, Division of Thoracic Radiology, University of Michigan Medical Center (United States); Deeb, G.M. [Division of Cardiac Surgery, University of Michigan Medical Center (United States); Williams, D.M. [Division of Vascular Interventional Imaging, University of Michigan Medical Center (United States)

    2007-09-15

    Aim: To determine and compare rates of descending aortic enlargement and complications in chronic aortic dissection with and without a proximal aortic graft. Methods and materials: Fifty-two patients with dissection involving the descending aorta and who had undergone at least two computed tomography (CT) examinations at our institution between November, 1993 and February, 2004 were identified, including 24 non-operated patients (four type A, 20 type B) and 28 operated patients (type A). CT examinations per patient ranged from two to 10, and follow-up ranged from 1-123 months (mean 49 months, median 38.5 months). On each CT image, the aortic short axis (SA), false lumen (FL), and true lumen (TL) diameters were measured at the longitudinal midpoint of the dissection and at the point of maximum aortic diameter. Complications were tabulated, including aortic rupture and aortic enlargement requiring surgery. Results: For non-operated patients, the midpoint and maximum point SA, TL, and FL diameters increased significantly over time. For operated patients, the midpoint and maximum point SA and FL diameters increased significantly over time. In both groups, aortic enlargement was predominantly due to FL expansion. Diameter increases in non-operated patients were significantly larger than those in operated patients. The rate of change in aortic diameter was constant, regardless of aortic size. Four non-operated and six operated patients developed aortic complications. Conclusions: In patients with a dissection involving the descending thoracic aorta, the FL increased in diameter over time, at a constant rate, and to a greater degree in non-operated patients (mostly type B) compared with operated patients (all type A)

  8. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  9. Breakthrough in Mars balloon technology

    Science.gov (United States)

    Kerzhanovich, V. V.; Cutts, J. A.; Cooper, H. W.; Hall, J. L.; McDonald, B. A.; Pauken, M. T.; White, C. V.; Yavrouian, A. H.; Castano, A.; Cathey, H. M.; Fairbrother, D. A.; Smith, I. S.; Shreves, C. M.; Lachenmeier, T.; Rainwater, E.; Smith, M.

    2004-01-01

    Two prototypes of Mars superpressure balloons were flight tested for aerial deployment and inflation in the Earth's stratosphere in June, 2002. One was an 11.3 m diameter by 6.8 m high pumpkin balloon constructed from polyethylene film and Zylon (PBO) tendons, the second was a 10 m diameter spherical balloon constructed from 12 μm thick Mylar film. Aerial deployment and inflation occurred under parachute descent at 34 km altitude, mimicing the dynamic pressure environment expected during an actual Mars balloon mission. Two on-board video cameras were used on each flight to provide real-time upward and downward views of the flight train. Atmospheric pressure and temperature were also recorded. Both prototypes successfully deployed from their storage container during parachute descent at approximately 40 m/s. The pumpkin balloon also successfully inflated with a 440 g charge of helium gas injected over a 1.5-min period. Since the helium inflation system was deliberately retained after inflation in this test, the pumpkin balloon continued to fall to the ocean where it was recovered for post-flight analysis. The less robust spherical balloon achieved only a partial (~70%) inflation before a structural failure occurred in the balloon film resulting in the loss of the vehicle. This structural failure was diagnosed to result from the vigorous oscillatory motion of the partially inflated balloon, possibly compounded by contact between the balloon film and an instrumentation box above it on the flight train. These two flights together represent significant progress in the development of Mars superpressure balloon technology and pave the way for future flight tests that will include post-deployment flight of the prototype balloons at a stable altitude.

  10. Titan Balloon Convection Model Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  11. O uso do balão intra-aórtico no pré-operatório de cirurgia de revascularização miocárdica, associada à disfunção ventricular grave The use of preoperative intra-aortic balloon in myocardial revascularization surgery associated to severe ventricular dysfunction

    Directory of Open Access Journals (Sweden)

    Marcelo Kern

    2006-02-01

    Full Text Available OBJETIVO: Avaliar a efetividade do Balão Intra-Aórtico (BIAo profilático em cirurgia de revascularização miocárdica (CRM eletiva, para prevenir o infarto trans ou pós-operatório e para reduzir a mortalidade intra-hospitalar nos pacientes com baixa fração de ejeção ventricular esquerda. MÉTODOS: Em modelo de estudo de coorte, foram analisados 239 pacientes com fração de ejeção do ventrículo esquerdo inferior ou igual a 40%, submetidos à CRM eletiva com circulação extracorpórea (CEC, no período compreendido entre março de 1995 a fevereiro de 2001. RESULTADOS: Destes, 58 pacientes receberam BIAo pré-operatório e os demais foram operados sem assistência circulatória (grupo controle. Os dois grupos de pacientes tinham características semelhantes quanto a fatores associados aos desfechos em questão. Ocorreram 5 (8,6% óbitos no grupo com BIAo e 21 (11,6%, no grupo controle (diferença não-signifícativa. Ocorreram 2 (3,4% infartos no grupo com BIAo e 28 (15,5%, no grupo controle BIAo (p OBJECTIVE: To evaluate the effectiveness of prophylactic intra-aortic balloon (IAB in elective myocardial revascularization surgery (MRS, to prevent trans or post-operative infarction and reduce intra-hospital mortality in patients with low left ventricular ejection fraction. METHODS: Using a cohort study model, 239 patients with left ventricular ejection fraction <40%, submitted to elective MRS with extracorporeal circulation (ECC were evaluated from March 1995 to February 2001. RESULTS: Of these, 58 patients received preoperative IAB and the remainder underwent surgery without circulatory assistance (control group. The two groups of patients had similar characteristics regarding factors associated to the pertaining outcomes. There were five demises (8.6% in the group with IAB and 21 (11.6% in the control group (non-significant difference. There were 2 (3.4% infarctions in the IAB group and 28 (15.5% in the control group (p< 0

  12. Transcatheter aortic valve implantation in a patient with bicuspid aortic stenosis and a borderline-sized annulus.

    Science.gov (United States)

    Colkesen, Yucel; Baykan, Oytun; Dagdelen, Sinan; Cayli, Murat

    2015-11-01

    Bicuspid aortic valve (BAV) is currently considered an exclusion criterion for transcatheter aortic valve implantation (TAVI). The risk of adverse aortic events such as incomplete sealing, severe paravalvular regurgitation or dislocation due to elliptic shape and asymmetric calcifications in annulus are higher in TAVI. In this case report, we detailed a case of successful trans-femoral TAVI in a 51-year old male with BAV and its management without in-hospital and 30-day complications. The challenge in this case was the patient's anatomy with a 27-mm annulus for balloon expandable device. The applied strategy was balloon sizing and overdilating the 29-mm stented valve with additional volume that obviated re-ballooning. Trans-femoral TAVI was performed uneventfully under fluoroscopic and transoesophageal echocardiography guidance. A multidetector computed tomography (MDCT) evaluation at 1 month did not show device dislodgement or any other complications. Evidence for evaluation post-TAVI is not sufficient in BAV. We believe patients with BAV should undergo a comprehensive assessment after TAVI including MDCT evaluation. PMID:26265070

  13. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  14. A Methane Balloon Inflation Chamber

    Science.gov (United States)

    Czerwinski, Curtis J.; Cordes, Tanya J.; Franek, Joe

    2005-01-01

    The various equipments, procedure and hazards in constructing the device for inflating a methane balloon using a standard methane outlet in a laboratory are described. This device is fast, safe, inexpensive, and easy to use as compared to a hydrogen gas cylinder for inflating balloons.

  15. Nationwide Eclipse Ballooning Project

    Science.gov (United States)

    Colman Des Jardins, Angela; Berk Knighton, W.; Larimer, Randal; Mayer-Gawlik, Shane; Fowler, Jennifer; Harmon, Christina; Koehler, Christopher; Guzik, Gregory; Flaten, James; Nolby, Caitlin; Granger, Douglas; Stewart, Michael

    2016-05-01

    The purpose of the Nationwide Eclipse Ballooning Project is to make the most of the 2017 rare eclipse event in four main areas: public engagement, workforce development, partnership development, and science. The Project is focused on two efforts, both student-led: online live video of the eclipse from the edge of space and the study of the atmospheric response to the eclipse. These efforts, however, involving more than 60 teams across the US, are challenging in many ways. Therefore, the Project is leveraging the NASA Space Grant and NOAA atmospheric science communities to make it a success. The first and primary topic of this poster is the NASA Space Grant supported online live video effort. College and high school students on 48 teams from 31 states will conduct high altitude balloon flights from 15-20 locations across the 8/21/2017 total eclipse path, sending live video and images from near space to a national website. Video and images of a total solar eclipse from near space are fascinating and rare. It’s never been done live and certainly not in a network of coverage across a continent. In addition to the live video to the web, these teams are engaged in several other science experiments as secondary payloads. We also briefly highlight the eclipse atmospheric science effort, where about a dozen teams will launch over one hundred radiosondes from across the 2017 path, recording an unprecedented atmospheric data sample. Collected data will include temperature, density, wind, humidity, and ozone measurements.

  16. Aortic Valve Sparing in Different Aortic Valve and Aortic Root Conditions.

    Science.gov (United States)

    David, Tirone E

    2016-08-01

    The development of aortic valve-sparing operations (reimplantation of the aortic valve and remodeling of the aortic root) expanded the surgical armamentarium for treating patients with aortic root dilation caused by a variety of disorders. Young adults with aortic root aneurysms associated with genetic syndromes are ideal candidates for reimplantation of the aortic valve, and the long-term results have been excellent. Incompetent bicuspid aortic valves with dilated aortic annuli are also satisfactorily treated with the same type of operation. Older patients with ascending aortic aneurysm and aortic insufficiency secondary to dilated sinotubular junction and a normal aortic annulus can be treated with remodeling of the aortic root or with reimplantation of the aortic valve. The first procedure is simpler, and both procedures are likely equally effective. As with any heart valve-preserving procedure, patient selection and surgical expertise are keys to successful and durable repairs. PMID:27491910

  17. How much of the intraaortic balloon volume is displaced toward the coronary circulation?

    OpenAIRE

    Kolyva, C; Pantalos, GM; Pepper, JR; Khir, AW

    2010-01-01

    This is a post-print version of the published article. Copyright @ 2010 The American Association for Thoracic Surgery. This article has been made available through the Brunel Open Access Publishing Fund. Objective: During intraaortic balloon inflation, blood volume is displaced toward the heart (Vtip), traveling retrograde in the descending aorta, passing by the arch vessels, reaching the aortic root (Vroot), and eventually perfusing the coronary circulation (Vcor). Vcor leads to corona...

  18. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... opens freely when the heart contracts. On the right, we see a picture of the aortic valve ... the aortic valve because the probe is sitting right behind the aortic valve. Lots of patients on ...

  19. Relationship between Enhanced Intensity of Contrast Enhanced Ultrasound and Microvessel Density of Aortic Atherosclerostic Plaque in Rabbit Model

    OpenAIRE

    Xiangdong You; Pintong Huang; Chao Zhang; Minghui Wang; Ying Zhang; Yurong Hong; Shumei Wei; Chunmei Liu; Zhaoxia Pu; Jianmin Zhang; Shuyuan Chen

    2014-01-01

    The aim of this study was to evaluate the relationship between enhanced intensity of contrast enhanced ultrasound and microvessel density of aortic atherosclerotic plaque in rabbit model. The abdominal aortas of thirty-six male New Zealand rabbits were damaged by balloon expansion and the animals were then fed a high fat diet for 12 weeks. Twenty-seven plaques on the near aortic wall were detected using conventional ultrasound examination. The maximum thickness of each plaque was recorded. CE...

  20. Abdominal Aortic Aneurysms: Treatments

    Science.gov (United States)

    ... access catheters Vertebroplasty Women and vascular disease Women's health Social Media Facebook Twitter ... Abdominal Aortic Aneurysms Interventional Radiologists Treat Abdominal Aneurysms Nonsurgically Interventional radiologists are vascular ...

  1. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  2. Correlation of Preoperative Renal Insufficiency With Mortality and Morbidity After Aortic Valve Replacement: A Propensity Score Matching Analysis

    Science.gov (United States)

    Lin, Chun-Yu; Tsai, Feng-Chun; Chen, Yung-Chang; Lee, Hsiu-An; Chen, Shao-Wei; Liu, Kuo-Sheng; Lin, Pyng-Jing

    2016-01-01

    Abstract Preoperative end-stage renal disease carries a high mortality and morbidity risk after aortic valve replacement (AVR), but the effect of renal insufficiency remains to be clarified. Through propensity score analysis, we compared the preoperative demographics, perioperative profiles, and outcomes between patients with and without renal insufficiency. From August 2005 to November 2014, 770 adult patients underwent AVR in a single institution. Patients were classified according to their estimated glomerular infiltration rate (eGFR) as renal insufficiency (eGFR: 30–89 mL/min/1.73 m2) or normal (eGFR, ≥90 mL/min/1.73 m2). Propensity scoring was performed with a 1:1 ratio, resulting in a matched cohort of 88 patients per group. Demographics, comorbidities, and surgical procedures were well balanced between the 2 groups, except for diabetes mellitus and eGFR. Patients with renal insufficiency had higher in-hospital mortality (19.3% versus 3.4%, P 72 hour; 25% versus 9.1%, P = .008), intensive care unit stays (8.9 ± 9.9 versus 4.9 ± 7.5 days, P = .046), and hospital stays (35.3 ± 31.7 versus 24.1 ± 20.3 days, P = .008), compared with those with normal renal function. Multivariate analysis confirmed that preoperative renal insufficiency was an in-hospital mortality predictor (odds ratio, 2.33; 95% confidence interval, 1.343–4.043; P = .003), as were prolonged cardiopulmonary bypass time, intraaortic balloon pump support, and postoperative hemodialysis. The 1-year survival significantly differed between the 2 groups including (normal 87.5% versus renal insufficiency 67.9%, P < .001) or excluding in-hospital mortality (normal 90.7% versus renal insufficiency 82.1%, P = .05). Patients with preoperative renal insufficiency who underwent AVR had higher in-hospital mortality rates and increased morbidities, especially those associated with hemodynamic instabilities requiring intraaortic balloon pump support or

  3. Superpressure Tow Balloon for Extending Durations and Modifying Trajectories of High Altitude Balloon Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation involves the concept of using a Superpressure Tow Balloon (STB) with existing NASA high altitude balloon designs to form a tandem balloon...

  4. Imaging in aortic dissection

    International Nuclear Information System (INIS)

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.)

  5. Aortic arch malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kellenberger, Christian J. [University Children' s Hospital, Department of Diagnostic Imaging, Zuerich (Switzerland)

    2010-06-15

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  6. Mycotic Saccular Abdominal Aortic Aneurysm in an Infant after Cardiac Catheterization: A Case Report.

    Science.gov (United States)

    Benrashid, Ehsan; McCoy, Christopher C; Rice, Henry E; Shortell, Cynthia K; Cox, Mitchell W

    2015-10-01

    Abdominal aortic aneurysms (AAAs) are a rare entity in the pediatric population. Children with mycotic (infectious) AAA in particular are at risk of life-threatening rupture due to their rapid expansion coupled with aortic wall thinning and deterioration. Here, we present the case of a 10-month-old infant with prior 2-staged repair for hypoplastic left heart syndrome that was incidentally discovered to have a mycotic AAA on abdominal ultrasound (US) for evaluation of renovascular hypertension. Before the time of evaluation with US, the infant had developed methicillin-resistant Staphylococcus aureus bacteremia 3 days after cardiac catheterization with percutaneous thoracic aortic balloon angioplasty. She had normal aortic contours on contrasted computed tomography scan of the abdomen approximately 2 weeks before the aforementioned US evaluation. This infant subsequently underwent open aneurysmorrhaphy with cryopreserved vein patch angioplasty with resolution of her aneurysmal segment.

  7. BLOCKING SUN WITH ORBITING BALLOONS

    Energy Technology Data Exchange (ETDEWEB)

    Chul Park [Department of Aerospace Engineering, Kor ea Advanced Institute of Science and Technology, Daejeon (Korea)

    2008-09-30

    Sun's radiation power reaching Earth's surface can be reduced by letting large balloons circle the Earth in orbits at approximately 1000 km altitude. These balloons, made of plastic films 1 mm in thickness, of a diameter of approximately 46 km, will weigh about 10,000 tons each. A balloon will consist of one hundred of 100 ton pieces. They are transported to the orbit piece by piece, and are assembled there into the spherical shape. They are kept inflated with the vapor pressure of potassium and the electrostatic forces. The inclination angles of these balloons with respect to the solar ecliptic plane can be varied from zero to 90 degrees, although efficiency is highest with the zero degree inclination. If zero degree inclination is chosen, twenty-three of these will reduce the average sun's radiation by 0.01%. In the 1000 km orbits, which are stable and are populated only by space debris, these balloons will serve also to remove the debris.

  8. Sensor System for Super-Pressure Balloon Performance Modeling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-duration balloon flights are an exciting new area of scientific ballooning, enabled by the development of large super-pressure balloons. As these balloons...

  9. Off-Pump Repair of a Post Myocardial Infarction Ventricular Septal Defect

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2014-01-01

    Full Text Available Refractory cardiogenic shock meant that traditional patch repairs requiring cardiopulmonary bypass would be poorly tolerated and external sandwich closure of post myocardial ventricular septal defect (VSD appears to be simple and effective after initial myocardial infarction (MI. The three cases presented with a VSD after of acute MI with or without thrombolysed with streptokinase during patient admission. The general condition of the three patients was poor with pulmonary edema, low cardiac output and renal failure. The heart was approached through a median sternotomy. Off-pump coronary artery bypass grafting of the coronary artery lesion was done first using octopus and beating heart surgery method and latero - lateral septal plication was performed using sandwich technique. Low cardiac output managed with intra-aortic balloon pump in these patients accompanied with inotropic drugs. Post-operative transesophageal echocardiography revealed that VSD was closed completely in one patient and in two patients small residual VSD remained. More experience is required to ascertain whether this technique will become an accepted alternative to patch repairs.

  10. Balloon Exoplanet Nulling Interferometer (BENI)

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Woodruff, Robert A.; Vasudevan, Gopal; Ford, Holland; Petro, Larry; Herman, Jay; Rinehart, Stephen; Carpenter, Kenneth; Marzouk, Joe

    2009-01-01

    We evaluate the feasibility of using a balloon-borne nulling interferometer to detect and characterize exosolar planets and debris disks. The existing instrument consists of a 3-telescope Fizeau imaging interferometer with 3 fast steering mirrors and 3 delay lines operating at 800 Hz for closed-loop control of wavefront errors and fine pointing. A compact visible nulling interferometer is under development which when coupled to the imaging interferometer would in-principle allow deep suppression of starlight. We have conducted atmospheric simulations of the environment above 100,000 feet and believe balloons are a feasible path forward towards detection and characterization of a limited set of exoplanets and their debris disks. Herein we will discuss the BENI instrument, the balloon environment and the feasibility of such as mission.

  11. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  12. Application of new balloon catheters in the treatment of congenital heart defects

    Science.gov (United States)

    Fiszer, Roland; Szkutnik, Małgorzata; Smerdziński, Sebastian; Chodór, Beata; Białkowski, Jacek

    2016-01-01

    Introduction Balloon angioplasty (BAP) and aortic or pulmonary balloon valvuloplasty (BAV, BPV) are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland) launched and developed. These catheters have not been clinically evaluated yet. Material and methods We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF), 10 BAV and 27 BAP in coarctations of the aorta (CoA) – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations), 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean), BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin). No such complication occured with Valver II. Conclusions Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses. PMID:27625686

  13. Isoform-specific Regulation of Sodium pump α-subunit Gene Expression i n Aortic Smooth Muscle Cell of 1-kidney-1-clip Hypertensive Rats%“一肾一夹”高血压大鼠动脉平滑肌细胞钠泵α亚单位的基因表达

    Institute of Scientific and Technical Information of China (English)

    原卫清; 王颢; 吕卓人

    2001-01-01

    Objective To investigate the gene expression of sodium pump α-subunit in aortic smooth muscle of 1-kidney-1-clip (1k1c) hypertensive rats.  Methods 1k1c hypertensive rats were prepared by partially ligating the left renal artery and removing the right kidney. 4 weeks later, all the rats were killed and sodium pump α1- , α2-, and α3-subunit in aortic smooth muscles were detected with reverse transcription p ol ymerase chain reaction (RT-PCR) method and immunohistochemical assay at both mR NA and protein levels, respectively.  Resulsts Changes in the expression of sodi um pump α-subunit gene were found in aortic smooth muscles of 1k1c hypertensiv e rats: α1-su bunit increased at both mRNA protein levels, while α2- and α3-subunits r emained without changes.  Conclusions There were great changes in the gene expression of so dium pump α-subunit in aor tic smooth muscles of 1k1c hypertensive rats, which might be related to the development of hypertension in this hypertensive model.%目的 探讨“一肾一夹(1k1c)”高血压大鼠动脉平滑肌细胞钠泵α亚单位各异构体基 因表达的改变,为高血压发病机制的深入研究提供理论及实验依据。方法 分别应用分子生物学 RT-PCR及免疫组化技术,探讨1k1c高血压大鼠动脉平滑肌细胞钠泵α1、α2及α3亚单位mR NA及蛋白 水平基因表达的改变。结果 1k1c高血压大鼠动脉平滑肌细胞钠泵α亚单位基因表达发生改变: 无论在mRNA或蛋白水平,α1亚单位表达增强,而α2与α3亚单位表达无改变。结论 1k1c高血压大鼠动脉平滑肌细胞钠泵α亚单位基因表达发生改变,这种 改变可能参与了该模型的血压升高 机制。

  14. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... as atherosclerosis, high blood pressure, smokers, or a family history of abdominal aortic aneurysms. Today’s patient is ... be screened. In fact, patients who have a family history of aneurysm, men who are smoking over ...

  15. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... wall will actually thin out. And the big risk here is that if this gets too big ... to the aging baby boomers. Next slide. The risk factors for abdominal aortic aneurysms are males over ...

  16. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... atherosclerosis, high blood pressure, smokers, or a family history of abdominal aortic aneurysms. Today’s patient is a ... screened. In fact, patients who have a family history of aneurysm, men who are smoking over the ...

  17. Patterns of responding on a balloon analogue task reveal individual differences in overall risk-taking: choice between guaranteed and uncertain cash.

    Science.gov (United States)

    Robles, Elias; Emery, Noah N; Vargas, Perla A; Moreno, Araceli; Marshall, Brent; Grove, Richard C; Zhang, Huateng

    2014-01-01

    We explored the utility of analyzing within- and between-balloon response patterns on a balloon analogue task (BAT) in relation to overall risk scores, and to a choice between a small guaranteed cash reward and an uncertain reward of the same expected value. Young adults (n = 61) played a BAT, and then were offered a choice between $5 in cash and betting to win $0 to $15. Between groups, pumping was differentially influenced by explosions and by the number of successive unexploded balloons, with risk takers responding increasingly on successive balloons after an explosion. Within-balloons, risk takers showed a characteristic pattern of constant high rate, while non-risk takers showed a characteristic variable lower rate. Overall, results show that the higher number of pumps and explosions that characterize risk takers at a molar level, result from particular forms of adaptation to the positive and negative outcomes of choices seen at a molecular level. PMID:24940812

  18. Ballonnen in zee = balloons as marine litter

    NARCIS (Netherlands)

    Franeker, van J.A.

    2008-01-01

    Releasing balloons seems harmless. However, remains of balloons, especially valves and ribbons are becoming a common and persistent type of marine litter found on beaches. Following Dutch Queens day 2007, large numbers of Dutch balloons were found in Normandy, France. Animals may become entangled in

  19. Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

    Science.gov (United States)

    Kogut, Alan; James, Bryan; Fixsen, Dale

    2013-01-01

    Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then

  20. 穿透型胎盘植入行腹主动脉球囊置入的围术期管理1例%Perioperative management of abdominal aortic balloon occlusion in patients compli-cated with placenta percteta:a case report

    Institute of Scientific and Technical Information of China (English)

    曾鸿; 王妍; 王阳; 郭向阳

    2015-01-01

    SUMMARY When placenta previa complicated with placenta percreta, the exposure of operative field is difficult and the routine methods are difficult to effectively control the bleeding, even causing life-threatening results. A 31-year-old woman, who had been diagnosed with a complete type of placenta pre-via and placenta percreta with bladder invasion at 34 weeks gestation. Her ultrasound results showed a complete type of placenta previa and there was a loss of the decidual interface between the placenta and the myometrium on the lower part of the uterus, suggestive of placenta increta. For further evaluation of the placenta, pelvis magnetic resonance imaging was performed, which revealed findings suspicious of a placenta percreta. She underwent elective cecarean section at 36 weeks of gestation. Firstly, two ureteral stents were placed into the bilateral ureter through the cystoscope. After the infrarenal abdominal aorta catheter was inserted via the femoral artery ( 9 F sheath ) , subarachnoid anesthesia had been estab-lished. A healthy 2 510 g infant was delivered, with Apgar scores of 10 at 1 min and 10 at 5 min. Imme-diately after the baby was delivered, following which there was massive haemorrhage and general anaes-thesia was induced. The balloon catheter was immediately inflated until the wave of dorsal artery disap-peared. With the placenta retained within the uterus, a total hysterectomy was performed. The occluding time was 30 min. The intraoperative blood loss was 2 500 mL. The occluding balloon was deflated at the end of the operation. The patient had stable vital signs and normal laboratory findings during the recovery period and the hemoglobin was 116 g/L. She was discharged six days after delivery without intervention-related complications. This case illustrates that temporary occlusion of the infrarenal abdominal aorta using balloon might be a safe and effective treatment option for patients with placenta previa complicated with placenta percreta

  1. [Inflammatory abdominal aortic aneurysm].

    Science.gov (United States)

    Ziaja, K; Sedlak, L; Urbanek, T; Kostyra, J; Ludyga, T

    2000-01-01

    The reported incidence of inflammatory abdominal aortic aneurysm (IAAA) is from 2% to 14% of patients with abdominal aortic aneurysm and the etiology of this disease is still discussed--according to the literature several pathogenic theories have been proposed. From 1992 to 1997 32 patients with IAAA were operated on. The patients were mostly symptomatic--abdominal pain was present in 68.75% cases, back pain in 31.25%, fever in 12.5% and weight loss in 6.25% of the operated patients. In all the patients ultrasound examination was performed, in 4 patients CT and in 3 cases urography. All the patients were operated on and characteristic signs of inflammatory abdominal aortic aneurysm like: thickened aortic wall, perianeurysmal infiltration or retroperitoneal fibrosis with involvement of retroperitoneal structures were found. In all cases surgery was performed using transperitoneal approach; in three cases intraoperatively contiguous abdominal organs were injured, which was connected with their involvement into periaortic inflammation. In 4 cases clamping of the aorta was done at the level of the diaphragmatic hiatus. 3 patients (9.37%) died (one patient with ruptured abdominal aortic aneurysm). Authors present diagnostic procedures and the differences in the surgical tactic, emphasizing the necessity of the surgical therapy in patients with inflammatory abdominal aortic aneurysm.

  2. Three-year-old child with middle aortic syndrome treated by endovascular stent implantation.

    Science.gov (United States)

    Moszura, Tomasz; Goreczny, Sebastian; Dryzek, Pawel; Niwald, Marek

    2013-04-01

    Middle aortic syndrome (MAS) is an extremely rare anomaly and represents both a diagnostic and therapeutic challenge, particularly in young children. A case of a 3.5 year-old child with MAS and arterial hypertension is reported, where owing to the patient's young age and the length of the hypoplastic aortic segment, surgical correction with end-to-end anastomosis was not feasible. Instead of palliative bypass grafting between the thoracic and abdominal aorta, successful percutaneous balloon angioplasty and stenting of the lesion was performed with the assistance of three-dimensional rotational angiography.

  3. Suprarenal fixation resulting in intestinal malperfusion after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Siani, Andrea; Accrocca, Federico; De Vivo, Gennaro; Marcucci, Giustino

    2016-05-01

    Superior mesenteric artery (SMA) and coeliac axis (CA) occlusion after endovascular abdominal aneurysm aortic repair (EVAR-AAA), using endograft with suprarenal fixation, are uncommon. However, we are reporting a case of visceral malperfusion, which occurred 7 days after successful EVAR with suprarenal fixation for symptomatic AAA. Endograft metal stent barbs caused severe stenosis of SMA and CA. A successful recovery of SMA was carried out by means of a balloon-expandable stent released through bare metal stent barbs. We believe that an unfavourable anatomy of a proximal aortic neck and visceral aorta may have caused a wrong stent strut deployment with the coverage of CA and SMA. PMID:26826712

  4. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  5. Global electrodynamics from superpressure balloons

    Science.gov (United States)

    Holzworth, R. H.; Hu, H.

    1995-01-01

    Electric field and conductivity measurements in the stratosphere between November 1992 and March 1993 have been made using superpressure balloons in the southern hemisphere. Over 400 payload-days of data have been made during a record setting experiment called ELBBO (Extended Life Balloon Borne Observatories). This experiment resulted in 4 flights aloft simultaneously for over 2 months including one flight which lasted over 4 months. Electrodynamical coupling between the atmosphere and ionosphere is studied using the measured electric fields, and a simple empirical model of the stratospheric conductivity. Altitude profiles of conductivity have been obtained from several superpressure balloon flights using the large end-of-flight altitude swings on the last few days of each flight (as the balloon begins to loose superpressure). Coupling between the fields and atmospheric inertial waves has been observed. Effects and dynamics of the global circuit suggest that standard models are missing significant phenomena. Large scale ionospheric convection activity has been studied from the polar cap to the middle latitudes. Cusp latitude fields have been continuously measured for many days in a row.

  6. Valvoplastia aórtica por cateter-balão em emergência materno-fetal na adolescência Valvuloplastia aórtica por catéter con balón en emergencia materno-fetal en la adolescencia Aortic valvuloplasty with balloon catheter in maternal-fetal emergency in adolescence

    Directory of Open Access Journals (Sweden)

    Walkiria Samuel Avila

    2009-12-01

    Full Text Available O aumento do débito cardíaco durante a gravidez é causa de insuficiência cardíaca em portadoras de estenose valvar aórtica grave. A valvoplastia aórtica percutânea tem sido associada a graves complicações e reestenose valvar em curto prazo. O presente caso mostrou que a valvoplastia aórtica percutânea permitiu o alcance do parto com sobrevida da mãe e do feto, e que a interrupção do tratamento no pós-parto resultou em morte materna no puerpério tardio.El aumento del gasto cardiaco durante el embarazo es la causa de insuficiencia cardiaca en portadoras de estenosis valvular aórtica severa. Se viene asociando la valvuloplastia aórtica percutánea a severas complicaciones y reestenosis valvular en corto plazo. El presente caso reveló que la valvuloplastia aórtica percutánea permitió el alcance del parto con sobrevida de la madre y del feto, y que la interrupción del tratamiento en el postparto resultó en muerte materna en el puerperio tardío.The increase of cardiac output during pregnancy is the cause of heart failure in women with severe aortic valvular stenosis. Percutaneous aortic valvuloplasty has been associated with severe complications and short-term valvar restenosis. This case showed that percutaneous aortic valvuloplasty allowed both mother and fetus to survive after childbirth, and that postpartum treatment interruption resulted in maternal death in late postpartum care.

  7. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  8. Reoperative transapical transcatheter aortic valve replacement for central aortic regurgitation.

    Science.gov (United States)

    Zhu, Yuanjia; Kapadia, Samir; Krishnaswamy, Amar; Svensson, Lars G; Mick, Stephanie

    2016-09-01

    Paravalvular leak-related aortic regurgitation after transcatheter aortic valve replacement (TAVR) is a common complication and is associated with increased short- and long-term mortality. However, the impact of isolated central aortic regurgitation is unknown. We report a case of transapical (TA) TAVR with postprocedural central aortic regurgitation, who returned after two years with progression of regurgitation. A reoperative valve-in-valve TA-TAVR was performed. PMID:27405799

  9. Aortic regurgitation after transcatheter aortic valve replacement.

    Science.gov (United States)

    Werner, Nikos; Sinning, Jan-Malte

    2014-01-01

    Paravalvular aortic regurgitation (AR) negatively affects prognosis following transcatheter aortic valve replacement (TAVR). As transcatheter heart valves (THV) are anchored using a certain degree of oversizing at the level of the aortic annulus, incomplete stent frame expansion because of heavily annular calcifications, suboptimal placement of the prosthesis, and/or annulus-prosthesis size-mismatch can contribute to paravalvular AR with subsequent increased mortality risk. Echocardiography is essential to differentiate between transvalvular and paravalvular AR and to further elucidate the etiology of AR during the procedure. However, because echocardiographic quantification of AR in TAVR patients remains challenging, especially in the implantation situation, a multimodal approach to the evaluation of AR with use of hemodynamic measurements and imaging modalities is useful to precisely quantify the severity of AR immediately after valve deployment. "Next-generation" THVs are already on the market and first results show that paravalvular AR related to design modifications (eg, paravalvular space-fillers, full repositionability) are rarely seen in these valve types.  PMID:24632758

  10. [Hemodynamic analysis of a centrifugal blood pump].

    Science.gov (United States)

    Wang, Yang; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Li, Qilei; Xu, Liang

    2015-01-01

    This paper built the mathematical model of a centrifugal blood pump, which was designed by ourselves, combined it with that of the human cardiovascular system and simulated the coupling system using Matlab. Then we set up the experiment platform, linked the blood pump to mock human cardiovascular system in case of three-stage heart failure, and measured aortic pressure and flow under different speed. The comparison between experiment results and simulation results not only indicates the coupling model is correct and the blood pump works well, but also shows that with the increase of blood pump speed, the pulsation of aortic pressure and flow will be reduced, this situation will affect the structure and function of blood vessels.

  11. [Hemodynamic analysis of a centrifugal blood pump].

    Science.gov (United States)

    Wang, Yang; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Li, Qilei; Xu, Liang

    2015-01-01

    This paper built the mathematical model of a centrifugal blood pump, which was designed by ourselves, combined it with that of the human cardiovascular system and simulated the coupling system using Matlab. Then we set up the experiment platform, linked the blood pump to mock human cardiovascular system in case of three-stage heart failure, and measured aortic pressure and flow under different speed. The comparison between experiment results and simulation results not only indicates the coupling model is correct and the blood pump works well, but also shows that with the increase of blood pump speed, the pulsation of aortic pressure and flow will be reduced, this situation will affect the structure and function of blood vessels. PMID:26027287

  12. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... conditions or other significant medical problems, the American College of Cardiology recommends aortic valve replacement for basically ... more likely we see aortic stenosis. Again, patient education is part of the evaluation and management of ...

  13. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... North Carolina. My name is John Streitman and I'm a cardiothoracic surgeon here at the Heart ... the corrective surgery of aortic valve replacement. If I have aortic stenosis, are there any activities that ...

  14. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... of that slide, that demonstrates that patients with New York Heart Association class heart failure 1 and ... right down the aortic valve and that's the new aortic valve that Dr. Streitman's placed. And you ...

  15. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... to help prevent aortic stenosis? There's no prophylactic methods that anybody can take to prevent aortic stenosis ... it will be archived on the ORlive Web site and ORlive.com and, of course, a link ...

  16. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  17. Aneurysms: thoracic aortic aneurysms.

    Science.gov (United States)

    Chun, Kevin C; Lee, Eugene S

    2015-04-01

    Thoracic aortic aneurysms (TAAs) have many possible etiologies, including congenital heart defects (eg, bicuspid aortic valves, coarctation of the aorta), inherited connective tissue disorders (eg, Marfan, Ehlers-Danlos, Loeys-Dietz syndromes), and degenerative conditions (eg, medial necrosis, atherosclerosis of the aortic wall). Symptoms of rupture include a severe tearing pain in the chest, back, or neck, sometimes associated with cardiovascular collapse. Before rupture, TAAs may exert pressure on other thoracic structures, leading to a variety of symptoms. However, most TAAs are asymptomatic and are found incidentally during imaging for other conditions. Diagnosis is confirmed with computed tomography scan or echocardiography. Asymptomatic TAAs should be monitored with imaging at specified intervals and patients referred for repair if the TAAs are enlarging rapidly (greater than 0.5 cm in diameter over 6 months for heritable etiologies; greater than 0.5 cm over 1 year for degenerative etiologies) or reach a critical aortic diameter threshold for elective surgery (5.5 cm for TAAs due to degenerative etiologies, 5.0 cm when associated with inherited syndromes). Open surgery is used most often to treat asymptomatic TAAs in the ascending aorta and aortic arch. Asymptomatic TAAs in the descending aorta often are treated medically with aggressive blood pressure control, though recent data suggest that endovascular procedures may result in better long-term survival rates. PMID:25860136

  18. Aortic Valve Disease

    Science.gov (United States)

    ... valve opens when the left ventricle squeezes to pump out blood, and closes in between heart beats to keep ... the left ventricle has to work harder to pump blood out through the valve. To do this extra ...

  19. Scientific ballooning in India: recent developments

    Science.gov (United States)

    Joshi, M. N.; Damle, S. V.

    The National Scientific Balloon Facility (NBF) of the Tata Institute of Fundamental Research (TIFR) has been conducting regular balloon flights for various experiments in the areas of Space Astronomy and Atmospheric Sciences. A continuous improvement in all aspects of Scientific Ballooning through a sustained R and D programme ensures uptodate services and a better handle on the design specifications for the balloon. Recent developments in balloon grade films, continuous improvements in design specifications, balloon manufacturing methods, flight operational procedures and improved balloon flight capabilities have resulted in a greatly improved flight performance in the last five years. A launch capability upgradation programme in terms of new launch spool and new launch vehicle has been initiated to be able to safely launch balloons with gross lifts upto 3500 kg, balloon volumes upto 450,000 m^3 and payloads upto 1400 kg. A series of steps have been initiated to improve long duration flight capabilities. In this paper, we present details on some of these aspects of Scientific Ballooning in India.

  20. A Mars 2011 Balloon Mission Trade Study

    Science.gov (United States)

    Smith, I.; Lew, T.; Perry, W.

    Mars Scouts are competitively selected PI-led missions to further Mars exploration in ways that satisfy NASA s overall objectives but are not currently in the planned line of missions The current 2006 Announcement of Opportunity AO for Mars Scouts has just closed The goal of this SwRI study was to develop a new balloon mission concept to where it could be credibly proposed for the AO The balloon system was defined in the study as consisting of two parts the balloon flight system BFS and the balloon deployment inflation system DIS The BFS includes the balloon envelope accessory hardware and gondola The balloon includes the envelope seams end fittings load core inflation tube diffusers payload tether shock attenuator and separation hardware The DIS includes the balloon container deployment hardware sequencer tankage gas and control hardware Trade studies were performed to better define the mission design space These studies included 1 effect of varied atmospheric thermal loads 2 effect of varying latitudes 3 effect of payload mass for varying altitudes 4 effect of radiative material properties on balloon size mass 5 effect of material areal densities on balloon size mass and 6 effect of inflation gas on system masses Results of the balloon trade study for the Mars 2011 mission opportunity will be presented

  1. Aortic wave dynamics and its influence on left ventricular workload.

    Directory of Open Access Journals (Sweden)

    Niema M Pahlevan

    Full Text Available The pumping mechanism of the heart is pulsatile, so the heart generates pulsatile flow that enters into the compliant aorta in the form of pressure and flow waves. We hypothesized that there exists a specific heart rate at which the external left ventricular (LV power is minimized. To test this hypothesis, we used a computational model to explore the effects of heart rate (HR and aortic rigidity on left ventricular (LV power requirement. While both mean and pulsatile parts of the pressure play an important role in LV power requirement elevation, at higher rigidities the effect of pulsatility becomes more dominant. For any given aortic rigidity, there exists an optimum HR that minimizes the LV power requirement at a given cardiac output. The optimum HR shifts to higher values as the aorta becomes more rigid. To conclude, there is an optimum condition for aortic waves that minimizes the LV pulsatile load and consequently the total LV workload.

  2. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... re just dilating this to just get very good attachment of the device to the wall, and now we’re deflating the balloon. Barry, as you do that, one thing I think we failed to mention, it’s very ...

  3. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  4. Inhibitory Effect of Diabetes on Proliferation of Vascular Smooth Muscle After Balloon Injury in Rat Aorta

    OpenAIRE

    Dahlfors, Gunilla; Chen, Yun; Gustafsson, Bertil; Arnqvist, Hans J.

    2000-01-01

    The effect of streptozotocin-induced diabetes on cell proliferation in rat aortic intima-media, as well as on local gene expression of transforming growth factor-β1 (TGF-β1) was studied. TGF-β1 mRNA was measured by solution hybridization and TGF-β1 protein by ELISA. Proliferation was measured by bromodeoxyuridine incorporation into DNA two days after balloon injury. All BrdU-labelled cells observed were smooth muscle cells. After a diabetes duration of 2 and 4 weeks, labelled cells were signi...

  5. Inflammatory aortic aneurysms

    DEFF Research Database (Denmark)

    Bitsch, M; Nørgaard, H H; Røder, O;

    1997-01-01

    operated on for abdominal aortic aneurysms without PF in the same period, served as reference group. RESULTS: Preoperative thickness of PF was assessed as > 1 cm in 11 and cm in 10 patients. Ureterolysis was performed in seven patients where the fibrosis caused ureteral obstruction. Postoperative CT...

  6. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... to repair an abdominal aortic aneurysm using a technology called an “endograft,” which is sometimes called the “ ... separate area, and it’s because of this small technology that allows you to do this. Exactly. So ...

  7. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... an abdominal aortic aneurysm. Normally this procedure takes us about 45 minutes to an hour of doctor work time, which is, I think, a fairly quick procedure to replace a major life-threatening problem in the patient’s abdomen. So you can see ...

  8. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... the arteries, which is known as atherosclerosis, high blood pressure, smokers, or a family history of abdominal aortic ... imaging. We can integrate ultrasound imaging, the patient’s blood pressure, and so it’s a little bit like being ...

  9. Simulation study and function analysis of the dynamic aortic valve

    Institute of Scientific and Technical Information of China (English)

    XIA Dongdong; BAI Jing

    2006-01-01

    The dynamic aortic valve (DAV) is a new left ventricular assist device, a micro-axial blood pump implemented at the position of the aortic valve, pumping blood from the left ventricle into the aortic artery. The present dynamic aortic valve operates at 7 different rotation speeds, ranging from 3000 r/min (speed 1) to 9000 r/min (speed 7). Because in vivo experiments need a lot of live animals and take a long period of time, modeling and simulation have been widely used to simulate and analyze hydra-dynamic property of the DAV and its assisting effects. With the measurements from the mock circulatory loop, a mathematic model of the DAV is established and embedded into the previously developed canine circulatory system. Using this model, the effect of the DAV on the failing heart at each rotation speed level is investigated. The vital cardiac variables are computed and compared with in vivo experimental results, which are in good agreement with an acceptable difference mostly 15 %. The establishment of the DAV model and its simulation are useful for further improvement of the DAV device.

  10. Hyperspectral Polarimeter for Monitoring Balloon Strain Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously...

  11. Scientific Ballooning Activities and Recent Developments in Technology and Instrumentation of the TIFR Balloon Facility, Hyderabad

    Science.gov (United States)

    Buduru, Suneel Kumar

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.

  12. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  13. Lifting options for stratospheric aerosol geoengineering: advantages of tethered balloon systems.

    Science.gov (United States)

    Davidson, Peter; Burgoyne, Chris; Hunt, Hugh; Causier, Matt

    2012-09-13

    The Royal Society report 'Geoengineering the Climate' identified solar radiation management using albedo-enhancing aerosols injected into the stratosphere as the most affordable and effective option for geoengineering, but did not consider in any detail the options for delivery. This paper provides outline engineering analyses of the options, both for batch-delivery processes, following up on previous work for artillery shells, missiles, aircraft and free-flying balloons, as well as a more lengthy analysis of continuous-delivery systems that require a pipe connected to the ground and supported at a height of 20 km, either by a tower or by a tethered balloon. Towers are shown not to be practical, but a tethered balloon delivery system, with high-pressure pumping, appears to have much lower operating and capital costs than all other delivery options. Instead of transporting sulphuric acid mist precursors, such a system could also be used to transport slurries of high refractive index particles such as coated titanium dioxide. The use of such particles would allow useful experiments on opacity, coagulation and atmospheric chemistry at modest rates so as not to perturb regional or global climatic conditions, thus reducing scale-up risks. Criteria for particle choice are discussed, including the need to minimize or prevent ozone destruction. The paper estimates the time scales and relatively modest costs required if a tethered balloon system were to be introduced in a measured way with testing and development work proceeding over three decades, rather than in an emergency. The manufacture of a tether capable of sustaining the high tensions and internal pressures needed, as well as strong winds, is a significant challenge, as is the development of the necessary pumping and dispersion technologies. The greatest challenge may be the manufacture and launch of very large balloons, but means have been identified to significantly reduce the size of such balloons or aerostats.

  14. First direct aortic retrievable transcatheter aortic valve implantation in humans.

    Science.gov (United States)

    Chandrasekhar, Jaya; Glover, Chris; Labinaz, Marino; Ruel, Marc

    2014-11-01

    We describe 2 cases in which transcatheter aortic valve implantation was performed with a Portico prosthesis (St Jude Medical, St Paul, MN) through a direct aortic approach. In 1 of the cases, prosthesis retrieval was needed during the procedure and was essential to the successful outcome. This is the first report, to our knowledge, of direct aortic Portico prosthesis implantation, and it highlights the significance of the retrievable nature of this device. PMID:25442452

  15. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Objective: To summarize the clinical experience of perioperative management in performing endovascular abdominal aortic aneurysm repair (EVAR). Methods: EVAR was performed in 22 patients with abdominal aortic aneurysm. The clinical data were retrospectively analyzed. Before treatment the functions of main organs were evaluated and certain measures were adopted in order to protect them. Useful parameters, including the length, diameter, angle and configuration of the proximal and distal aneurysmal neck, the relationship of the aneurysm to aortic branches, the distance from the lowest renal artery to the bifurcation of abdominal aorta, and the quality of access vessels (such as diameter, tortuosity and calcification degree) were determined and assessed with CTA. According to the parameters thus obtained, the suitable stent-graft with ideal diameter and length was selected, and the optimal surgery pattern was employed. Local anesthesia was employed in 20 patients, among them the local anesthesia had to be changed to general anesthesia in one. Epidural anesthesia was carried out in one patient through the surgically-reconstructed iliac artery access,and general anesthesia was employed in one patient who had Stanford type A aortic dissection. The lowest renal artery must be accurately localized before deployment of stent-graft was started. At least one patent internal iliac artery should be reserved when bilateral internal iliac arteries needed to be covered, to be covered by stages or to be reconstructed. After stent-graft placement, angiography must be performed to find out if there was any endoleak and, if any, to determine the type of endoleak and to deal with it properly. Two cases had proximal type I endoleak, so balloon dilation was employed in one and cuff implantation in another one. Distal type I endoleak occurred in one case, but, unfortunately, the iliac artery ruptured when balloon dilation was employed, therefore the patient had to receive vascular repair

  16. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge G; Grønbæk, Morten;

    2012-01-01

    BACKGROUND: We determined the predictive power of tobacco smoking on aortic aneurysm as opposed to other risk factors in the general population. METHODS: We recorded tobacco smoking and other risk factors at baseline, and assessed hospitalization and death from aortic aneurysm in 15,072 individuals...... General Population Study, respectively. According to the magnitude of the hazard ratios, tobacco consumption was the most important risk factor for hospitalization and death from aortic aneurysm, followed by male sex and hypertension in both cohorts. The population attributable risk of aortic aneurysm...... outcomes due to tobacco consumption was 64% and 47% in the Copenhagen City Heart Study and Copenhagen General Population Study, respectively, and ranked highest among population attributable risks of aortic aneurysm in both cohorts. The absolute 10-year risk for hospitalization or death from aortic...

  17. Ross-Konno and Endocardial Fibroelastosis Resection After Hybrid Stage I Palliation in Infancy: Successful Staged Left-Ventricular Rehabilitation and Conversion to Biventricular Circulation After Fetal Diagnosis of Aortic Stenosis

    OpenAIRE

    Moon-Grady, Anita J.; Moore, Phillip; Azakie, Anthony

    2010-01-01

    We report a patient who presented during fetal life with severe aortic stenosis, left-ventricular dysfunction, and endocardial fibroelastosis (evolving hypoplastic left heart syndrome). Management involved in utero and postnatal balloon aortic valvuloplasty for partial relief of obstruction and early postnatal hybrid stage I palliation until recovery of left-ventricular systolic function had occurred. The infant subsequently had successful conversion to a biventricular circulation by combinin...

  18. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A;

    2008-01-01

    BACKGROUND AND AIMS OF THE STUDY: Prompted by anecdotal evidence and observations by surgeons, an investigation was undertaken into the potential differences in implanted aortic valve prosthesis sizes, during aortic valve replacement (AVR) procedures, between northern and southern European...... countries. METHODS: A multi-institutional, non-randomized, retrospective analysis was conducted among 2,932 patients who underwent AVR surgery at seven tertiary cardiac surgery centers throughout Europe. Demographic and perioperative variables including valve size and type, body surface area (BSA) and early......: Prostheses with diameter valve size was also smaller in southern compared to northern European patients (21.6 +/- 2.1 mm versus 23.4 +/- 2.2 mm, p

  19. Infrarenal Aortic Occlusion

    Science.gov (United States)

    Traverso, L. W.; Baker, J. D.; Dainko, E. A.; Machleder, H. I.

    1978-01-01

    Twenty-eight patients with total occlusion of the infrarenal aorta have been seen at the UCLA Hospitals in the past 11 years. Claudication was the presenting complaint in all but one patient, with one-third having ischemic rest pain. The average age of these patients was 54 years, and their histories revealed a surprising absence of myocardial infarction, stroke, or diabetes, although 40% had essential hypertension. Heavy tobacco use, however, was characteristic of the entire group. Arteriography proved valuable in identifying and characterizing the vascular abnormalities, but posed problems in technique and interpretation. Significant distal arterial disease was detected radiographically in only 21% of these patients. Operative correction of the aortic occlusion was performed on 26 patients, 18 by aortic bypass grafts and eight by aorto-iliac endarterectomy, with one early postoperative death. Although the thrombus extended to the renal artery origins in 77% of the cases, a well-designed technical approach did not require renal artery occlusion. Using serial creatinine determinations, one case of renal insufficiency was detected which was associated with prolonged postoperative hypotension. Although the extent of distal disease was more severe in those who underwent bypass, symptoms of claudication returned earlier and were more prominent in the endarterectomy group. This recurrence of systems was not favorably altered by sympathectomy performed concomitantly with the initial procedure. Even though this condition seems to pose difficult technical obstacles and has a poor prognosis, infrarenal aortic occlusion can be successfully treated by aortic bypass, with favorable long-term results, if particular attention is paid to elements of the preoperative evaluation and the intraoperative technical requirements peculiar to this relatively uncommon disease entity. ImagesFig. 1.Fig. 2.Fig. 3. PMID:646479

  20. Micromanaging Abdominal Aortic Aneurysms

    Directory of Open Access Journals (Sweden)

    Lars Maegdefessel

    2013-07-01

    Full Text Available The contribution of abdominal aortic aneurysm (AAA disease to human morbidity and mortality has increased in the aging, industrialized world. In response, extraordinary efforts have been launched to determine the molecular and pathophysiological characteristics of the diseased aorta. This work aims to develop novel diagnostic and therapeutic strategies to limit AAA expansion and, ultimately, rupture. Contributions from multiple research groups have uncovered a complex transcriptional and post-transcriptional regulatory milieu, which is believed to be essential for maintaining aortic vascular homeostasis. Recently, novel small noncoding RNAs, called microRNAs, have been identified as important transcriptional and post-transcriptional inhibitors of gene expression. MicroRNAs are thought to “fine tune” the translational output of their target messenger RNAs (mRNAs by promoting mRNA degradation or inhibiting translation. With the discovery that microRNAs act as powerful regulators in the context of a wide variety of diseases, it is only logical that microRNAs be thoroughly explored as potential therapeutic entities. This current review summarizes interesting findings regarding the intriguing roles and benefits of microRNA expression modulation during AAA initiation and propagation. These studies utilize disease-relevant murine models, as well as human tissue from patients undergoing surgical aortic aneurysm repair. Furthermore, we critically examine future therapeutic strategies with regard to their clinical and translational feasibility.

  1. Test-Retest Characteristics of the Balloon Analogue Risk Task (BART)

    OpenAIRE

    White, Tara L.; Lejuez, Carl W.; de Wit, Harriet

    2008-01-01

    The Balloon Analogue Risk Task (BART) is a computerized decision-making task that provides a test of behavioral risk taking. The task is increasingly used in laboratory settings and in the field with young adults and adolescents. However, there are currently no published data about the test-retest characteristics of the task when it is administered on separate days. The current paper addresses this gap. Risky behavior on the BART (adjusted average pumps) showed acceptable test-retest reliabil...

  2. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  3. Reevaluation of the balloon in gastrointestinal manometry.

    Science.gov (United States)

    Wilkes, P R; Hoskin, R W; Semlacher, E A; MacCannell, K L; Tyberg, J V

    1994-09-01

    Although the flow-through catheter (FTC) system has been useful and satisfactorily accurate for gastrointestinal manometry, we hypothesized that a cylindrical, liquid-filled balloon would also accurately reflect stress imposed by a sphincter. Latex balloons were fitted over the side ports of a closed-end catheter. The responses of the balloon and FTC system were compared in a cylindrical chamber commonly identified as a Starling resistor. Independent, constant-pressure sources were used to control both the inwardly directed "contact pressure" of the Starling resistor (Ps) and the intraluminal fluid pressure (P(lum)). The balloon transducers responded linearly and accurately (slope = 1) to changes in both Ps and P(lum) within the test range (0-200 mmHg, 0-26.7 kPa). When either P(lum) or Ps was held constant and the other changed, the balloon transducers always accurately measured the higher of the two pressures. Although the performance of the FTC system was improved after the Starling resistor was lubricated, the FTC system sometimes responded inaccurately to changes in Ps. The ability of the balloon transducers to measure the contractions of the lower esophageal sphincter and of the esophagus was demonstrated. We conclude that the balloon transducer can measure sphincter pressure accurately and suggest that, in certain circumstances, it might be advantageous relative to the FTC system. PMID:7842396

  4. Airborne Internet Providing Tethered Balloon System

    Directory of Open Access Journals (Sweden)

    Suvriti Dhawan1

    2015-12-01

    Full Text Available In this paper we shall introduce a new system for providing wireless network communication over a specified area using ’lighter than air’ balloons. This technology will replace the existing fiber optic network system. This will be done by using a tethered balloon along with the payload (containing a receiver, a transmitter and a radio communication device.This payload will be suspended from the ground at an altitude (depending on the area of coverage required. Users under this area will be able to access this system directly for internet connectivity. This system can be used over large areas like universities, companies and societies to provide internet facility to their users through Wi-Fi or over an area where the user is specified (commercial purposes. Currently Google is working on similar idea called the ’Google Loon’ in which they use high altitude balloons which float at an altitude twice as high as air planes and the weather. They recently tested this system over New-Zealand by providing internet to their pilot testers on ground. Their balloons not being stationary, move with directional winds and have to be replaced one after the other to maintain consistency. This can be a huge problem over the areas where upper atmospheric winds are not in favorable direction. We can resolve this problem by using our stationary tethered balloon system which can communicate with the loon balloons to provide internet facility over a desired area. Moreover when our balloon will communicate with the loon balloon it will increase the coverage area as the loon balloon has to communicate to a point which is above the ground. Our system will not only replace the existing fiber optic system but it will also be selfsustaining i.e. It will generate its own power using solar panels.

  5. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  6. Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons

    Science.gov (United States)

    Jadrich, James; Bruxvoort, Crystal

    2010-01-01

    Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…

  7. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  8. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  9. Cutting Balloon angioplasty for cardiac transplant vasculopathy.

    OpenAIRE

    Takano, Y.; Currier, JW; Yeatman, LA; Kobashigawa, JA; Rogers, AD; Cianfichi, LJ; Fishbein, MC; Tobis, JM

    2002-01-01

    We performed Cutting Balloon angioplasty on 20 lesions in 11 heart transplant recipients 7.5 +/- 3.8 years after transplantation. The mean percentage of diameter stenosis decreased from 88.3% +/- 13.8% to 19.6% +/- 13.7% after Cutting Balloon angioplasty without complication. Seven patients underwent follow-up angiography at 4.9 +/- 1.7 months in a total of 12 lesions, and all lesions showed restenosis with a mean diameter stenosis of 84.4% +/- 19.2%. Cutting Balloon angioplasty can be used t...

  10. The balloon and the airship technological heritage

    Science.gov (United States)

    Mayer, N. J.

    1981-01-01

    The balloon and the airship are discussed with emphasis on the identification of commonalities and distinctions. The aerostat technology behind the shape and structure of the vehicles is reviewed, including a discussion of structural weight, internal pressure, buckling, and the development of a stable tethered balloon system. Proper materials for the envelope are considered, taking elongation and stress into account, and flight operation and future developments are reviewed. Airships and tethered balloons which are designed to carry high operating pressure with low gas loss characteristics are found to share similar problems in low speed flight operations, while possessing interchangeable technologies.

  11. Stratospheric electric field measurements with transmediterranean balloons

    Science.gov (United States)

    de La Morena, B. A.; Alberca, L. F.; Curto, J. J.; Holzworth, R. H.

    1993-01-01

    The horizontal component of the stratospheric electric field was measured using a balloon in the ODISEA Campaign of Transmediterranean Balloon Program. The balloon flew between Trapani (Sicily) and El Arenosillo (Huelva, Spain) along the 39 deg N parallel at a height between 34 and 24 km. The high values found for the field on fair-weather and its quasi-turbulent variation, both in amplitude and direction, are difficult to explain with the classical electric field source. A new source, first described by Holzworth (1989), is considered as possibly causing them.

  12. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P valve replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  13. Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation

    Directory of Open Access Journals (Sweden)

    Karel Van Praet

    2015-07-01

    Full Text Available Aortic regurgitation and dilatation of the aortic root and ascending aorta are severe complications of acromegaly. The current trend for management of an aortic root aneurysm is valve-sparing root replacement as well as restoring the diameter of the aortic sinotubular junction (STJ and annulus. Our case report supports the recommendation that in patients with acromegaly, severe aortic root involvement may indicate the need for surgery.

  14. Abdominal aortic aneurysm surgery

    DEFF Research Database (Denmark)

    Gefke, K; Schroeder, T V; Thisted, B;

    1994-01-01

    The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 553......, 78% stated that their quality of life had improved or was unchanged after surgery and had resumed working. These data justify a therapeutically aggressive approach, including ICU therapy following AAA surgery, despite failure of one or more organ systems....

  15. Unoperated aortic aneurysm

    DEFF Research Database (Denmark)

    Perko, M J; Nørgaard, M; Herzog, T M;

    1995-01-01

    . No significant differences in survival for patients with dissecting and nondissecting AA were detected. In all, 132 patients (78%) died and 78 (59%) of them died of rupture. Mean time to rupture was 1,300 +/- 8 days. Cumulative 5-year hazard of rupture for the dissecting AA was twice that of the nondissecting (p......From 1984 to 1993, 1,053 patients were admitted with aortic aneurysm (AA) and 170 (15%) were not operated on. The most frequent reason for nonoperative management was presumed technical inoperability. Survivals for patients with thoracic, thoracoabdominal, and abdominal AA were comparable...

  16. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    Science.gov (United States)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  17. Development of a miniature intraventricular axial flow blood pump.

    Science.gov (United States)

    Yamazaki, K; Umezu, M; Koyanagi, H; Outa, E; Ogino, S; Otake, Y; Shiozaki, H; Fujimoto, T; Tagusari, O; Kitamura, M

    1993-01-01

    A new intraventricular axial flow blood pump has been designed and developed as a totally implantable left ventricular assist device (LVAD). This pump consists of an impeller combined with a guide-vane, a tube housing, and a DC motor. The pump is introduced into the LV cavity through the LV apex, and the outlet cannula is passed antegrade across the aortic valve. Blood is withdrawn from the LV through the inlet ports at the pump base, and discharged to the ascending aorta. Our newly developed axial flow pump system has the following advantages: 1) it is a simple and compact system, 2) minimal blood stasis both in the device and the LV cavity, 3) minimal blood contacting surface of the pump, 4) easy accessibility with a less invasive surgical procedure, and 5) low cost. A pump flow > 5 L/min was obtained against 100 mmHg differential pressure in the mock circulatory system. The pump could produce a passive pulsatile flow effect with a beating heart more efficiently than other non-pulsatile pumps because of minimal pressure drop and inertia along the bypass tract. Anatomic fit studies using dissected hearts of dilated cardiomyopathy (DCM) cadavers showed that this pump could smoothly pass through the aortic valve without any interference with mitral valve function. Recently, a dynamic pressure groove bearing and a miniature lip seal have been developed. The dynamic pressure groove bearing has a simple structure and acts as a pressure resistant sealing mechanism.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Aortic biomechanics in hypertrophic cardiomyopathy

    Science.gov (United States)

    Badran, Hala Mahfouz; Soltan, Ghada; Faheem, Nagla; Elnoamany, Mohamed Fahmy; Tawfik, Mohamed; Yacoub, Magdi

    2015-01-01

    Background: Ventricular-vascular coupling is an important phenomenon in many cardiovascular diseases. The association between aortic mechanical dysfunction and left ventricular (LV) dysfunction is well characterized in many disease entities, but no data are available on how these changes are related in hypertrophic cardiomyopathy (HCM). Aim of the work: This study examined whether HCM alone is associated with an impaired aortic mechanical function in patients without cardiovascular risk factors and the relation of these changes, if any, to LV deformation and cardiac phenotype. Methods: 141 patients with HCM were recruited and compared to 66 age- and sex-matched healthy subjects as control group. Pulse pressure, aortic strain, stiffness and distensibility were calculated from the aortic diameters measured by M-mode echocardiography and blood pressure obtained by sphygmomanometer. Aortic wall systolic and diastolic velocities were measured using pulsed wave Doppler tissue imaging (DTI). Cardiac assessment included geometric parameters and myocardial deformation (strain and strain rate) and mechanical dyssynchrony. Results: The pulsatile change in the aortic diameter, distensibility and aortic wall systolic velocity (AWS') were significantly decreased and aortic stiffness index was increased in HCM compared to control (P < .001) In HCM AWS' was inversely correlated to age(r = − .32, P < .0001), MWT (r = − .22, P < .008), LVMI (r = − .20, P < .02), E/Ea (r = − .16, P < .03) LVOT gradient (r = − 19, P < .02) and severity of mitral regurg (r = − .18, P < .03) but not to the concealed LV deformation abnormalities or mechanical dyssynchrony. On multivariate analysis, the key determinant of aortic stiffness was LV mass index and LVOT obstruction while the role LV dysfunction in aortic stiffness is not evident in this population. Conclusion: HCM is associated with abnormal aortic mechanical properties. The severity of cardiac

  19. Shielded Mars Balloon Launcher (SMBL) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences, along with its partner Vertigo Industries, proposes a novel approach to deployment of balloon-based payloads into the Martian atmosphere....

  20. Magnetometer for Balloons and UAVs Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR project will investigate a new, low-cost approach to atomic magnetometry that is suited for operation from UAVs and research balloons. Atomic...

  1. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  2. Attitude determination for balloon-borne experiments

    CERN Document Server

    Gandilo, N N; Amiri, M; Angile, F E; Benton, S J; Bock, J J; Bond, J R; Bryan, S A; Chiang, H C; Contaldi, C R; Crill, B P; Devlin, M J; Dober, B; Dore, O P; Farhang, M; Filippini, J P; Fissel, L M; Fraisse, A A; Fukui, Y; Galitzki, N; Gambrel, A E; Golwala, S; Gudmundsson, J E; Halpern, M; Hasselfield, M; Hilton, G C; Holmes, W A; Hristov, V V; Irwin, K D; Jones, W C; Kermish, Z D; Klein, J; Korotkov, A L; Kuo, C L; MacTavish, C J; Mason, P V; Matthews, T G; Megerian, K G; Moncelsi, L; Morford, T A; Mroczkowski, T K; Nagy, J M; Netterfield, C B; Novak, G; Nutter, D; O'Brient, R; Pascale, E; Poidevin, F; Rahlin, A S; Reintsema, C D; Ruhl, J E; Runyan, M C; Savini, G; Scott, D; Shariff, J A; Soler, J D; Thomas, N E; Trangsrud, A; Truch, M D; Tucker, C E; Tucker, G S; Tucker, R S; Turner, A D; Ward-Thompson, D; Weber, A C; Wiebe, D V; Young, E Y

    2014-01-01

    An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of SPIDER, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. ...

  3. Retrieving Balloon Data in Flight Project

    Data.gov (United States)

    National Aeronautics and Space Administration —   NASA has plans to fly stratospheric ULDBs for missions of 100 days or more in the next few years. As these balloons circumnavigate the globe multiple...

  4. Abdominal aortic grafting for spontaneous infrarenal abdominal aortic dissection.

    Science.gov (United States)

    Iwasaki, Hiroto; Shibuya, Takashi; Shintani, Takashi; Uenaka, Hisazumi; Suehiro, Shigefumi; Satoh, Hisashi

    2010-02-01

    This case report concerns a 62-year-old woman with spontaneous infrarenal abdominal aortic dissection, which developed into claudication and rest pain in the lower extremity. Multi-row detector computed tomography showed the entry site of the abdominal aortic dissection at the second lumbar artery, while the reentry site was found intraoperatively at the median sacral artery, indicating that the false lumen had progressed and compressed the true lumen. A direct approach involving grafting appears to be an effective procedure for resolving mesenteric and lower extremity hypoperfusion due to aortic dissection with a dilated false channel, even during the acute period. PMID:19879731

  5. Reinforced aortic root reconstruction for acute type A aortic dissection involving the aortic root

    Directory of Open Access Journals (Sweden)

    Han Qing-qi

    2013-06-01

    Full Text Available OBJECTIVE: There are debates regarding the optimal approach for AAAD involving the aortic root. We described a modified reinforced aortic root reconstruction approach for treating AAAD involving the aortic root. METHODS: A total of 161 patients with AAAD involving the aortic root were treated by our modified reinforced aortic root reconstruction approach from January 1998 to December 2008. Key features of our modified approach were placement of an autologous pericardial patch in the false lumen, lining of the sinotubular junction lumen with a polyester vascular ring, and wrapping of the vessel with Teflon strips. Outcome measures included post-operative mortality, survival, complications, and level of aortic regurgitation. RESULTS: A total of 161 patients were included in the study (mean age: 43.3 1 15.5 years. The mean duration of follow-up was 5.1 1 2.96 years (2-12 years. A total of 10 (6.2% and 11 (6.8% patients died during hospitalization and during follow-up, respectively. Thirty-one (19.3% patients experienced postoperative complications. The 1-, 3-, 5-, and 10-year survival rates were 99.3%, 98%, 93.8%, and 75.5%, respectively. There were no instances of recurrent aortic dissection, aortic aneurysm, or pseudoaneurysm during the entire study period. The severity of aortic regurgitation dramatically decreased immediately after surgery (from 28.6% to 0% grade 3-4 and thereafter slightly increased (from 0% to 7.2% at 5 years and 9.1% at 10 years. CONCLUSION: This modified reinforced aortic root reconstruction was feasible, safe and durable/effective, as indicated by its low mortality, low postoperative complications and high survival rate.

  6. Power Systems Design for Long Duration Ballooning

    Science.gov (United States)

    Stilwell, Bryan; Chuzel, Alain

    2016-01-01

    The Columbia Scientific Balloon Facility has been designing and building high-altitude balloon power systems for over 26 years. With that experience, we have found certain types of PV panels, batteries, and charge controllers that are reliable in stratospheric environments. The ultimate goal is to ensure that power systems will provide power reliably throughout the duration of an LDB flight. The purpose of this presentation is to provide some general guidelines and best practices for power system design.

  7. Test ventilation with smoke, bubbles, and balloons

    Energy Technology Data Exchange (ETDEWEB)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs.

  8. New stent delivery balloon: a technical note.

    Science.gov (United States)

    di Mario, C; Reimers, B; Reinhardt, R; Ferraro, M; Moussa, I; Colombo, A

    1997-12-01

    This study reports the first clinical application of a new noncompliant balloon composed of a middle polyurethane layer sandwiched between an inner layer of polyethylene terephtalate and an outer membrane that provides for consistent even expansion. With this balloon design, the very low compliance and high pressure resistance of polyethylene terephthalate are associated with the high elasticity of polyurethane, preventing balloon damage from stent crimping and expansion and allowing a firm embedding of the stent struts. Palmaz-Schatz stent implantation was successful in 33/35 stents (94%), and the two stents that could not be advanced up to the lesion were successfully withdrawn. High pressure expansion of the stent was obtained during deployment with no balloon ruptures at inflation pressures equal or lower than 16 atmospheres (atm). Accurate positioning of the stent was facilitated by the two markers at the balloon ends and by the optimal visualization after contrast injection, even with 6 Fr guiding catheters. This new delivery system maintains the advantages of hand-crimped stents on noncompliant balloons, reducing the risk of stent loss. PMID:9408637

  9. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  10. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  11. The French Balloon Program 2013 - 2017

    Science.gov (United States)

    Dubourg, Vincent; Vargas, André; Raizonville, Philippe

    2016-07-01

    With over 50 years' experience in the field, the French Centre National d'Etudes Spatiales (CNES) goes on supporting - as designer and operator - a significant scientific ballooning program. In particular so because balloons still give a unique and valuable access to near space science. From 2008 to 2013, an important renovation effort was achieved, beginning by Zero Pressure Balloons (ZPB) systems, to comply with more stringent Safety constraints and to the growing reliability and performance requirements from scientific missions. The paper will give an overview of the CNES new capabilities and services for operational balloon activities, and their availability status. The scientific launch campaigns of the past two years will be presented. A focus will be made on the results of the Stratoscience 2015 flight campaign from Timmins, Ontario, using the NOSYCA command and control system for ZPB, qualified in flight in 2013. In particular, the PILOT telescope successfully flew during the 2015 campaign, key figures about the flight and mission will be given. An outlook of the new stratospheric long duration flight systems currently in process of developement at CNES will be given, as well as the presentation of the Stratéole 2 project, dedicated to the survey of the low stratosphere and upper troposphere in equatorial regions, with a fleet of small suprer pressure balloons (SPB). As far as tropospheric balloons are concerned, the Aeroclipper initiative will be presented, aiming at qualifying a quasi-tethered balloon, pushed by the winds close to the sea surface, for the study of cyclones. The scientific launch campaigns and the main payloads in the study for the near future will also be presented.

  12. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... see we've used the cautery to achieve access to the sternum. On the left hand side ... wound, which allows us to get more ready access to the aorta and the aortic valve. The ...

  13. Transcatheter Aortic Heart Valve Thrombosis

    DEFF Research Database (Denmark)

    Hansson, Nicolaj C; Grove, Erik L; Andersen, Henning R;

    2016-01-01

    BACKGROUND: There is increasing focus on transcatheter heart valve (THV) thrombosis. However, there are limited data on incidence, clinical implications and predisposing factors of THV thrombosis following transcatheter aortic valve replacement (TAVR). OBJECTIVES: We assessed the incidence...

  14. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... No medications as such have been proven to slow that disease path life. Again, it's a progressive ... no medical therapy that has been proven to slow or reverse the process of aortic stenosis. Clearly, ...

  15. [ENDOVASCULAR ABDOMINAL AORTIC ANEURISM REPAIR].

    Science.gov (United States)

    Maĭstrenko, D N; Generalov, M I; Tarazov, P G; Zherebtsov, F K; Osovskikh, V V; Ivanov, A S; Oleshchuk, A N; Granov, D A

    2015-01-01

    The authors analyzed the single-center experience of treatment of 72 patients with abdominal aortic aneurisms and severe accompanied pathology. The aneurisms were repaired by stent-grafts. All the patients had abdominal aortic aneurisms with the diameters from 41 to 84 mm against the background of severe somatic pathology. It was a contraindication to planned open surgery. An installation of stent-graft was successful in all 72 follow-ups. It wasn't necessary to use a conversion to open surgery. The follow-up period consisted of 44,6?2,1 months. Control ultrasound and computer tomography studies hadn't revealed an increase of aneurism sack sizes or "eakages". A reduction of abdominal aortic aneurism sizes was noted in 37 patients on 4-5% during first year after operation. The stent-graft implantation extends the possibilities of abdominal aortic aneurism treatment for patients from a high surgical risk group. PMID:26234059

  16. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... to minimize their symptoms, but that doesn't impact the course of the disease itself. When I' ... more likely we see aortic stenosis. Again, patient education is part of the evaluation and management of ...

  17. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... for patients who would not tolerate well a traditional open operation or a less invasive operation, as ... physical reserve. So Barbara Bush recently had a traditional aortic valve replacement surgery. What makes a patient ...

  18. Adult thoracic and abdominal aortic

    Directory of Open Access Journals (Sweden)

    Randa O. Kaddah

    2016-06-01

    Conclusion: Aortic COA could be found in any segment of the aorta. Proper identification of the anatomical details and pressure gradient studies are important factors affecting the plan of management.

  19. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... symptoms and ultimately surgery may be in the future. The symptoms seen primarily with aortic stenosis at ... echocardiography is? Echocardiography is the use of ultrasound technology. Ultrasound technology is a form of the same ...

  20. CONGENITAL QUADRICUSPID AORTIC-VALVE

    NARCIS (Netherlands)

    BROUWER, MHJ; DEGRAAF, JJ; EBELS, T

    1993-01-01

    Two patients with a quadricuspid aortic valve are described, one of them with concomitant juxtaposed coronary orifices facing the right hand facing sinus. The etiology and incidence of this congenital anomaly will be discussed.

  1. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... somebody for this operation. Again, there's no medical therapy that has been proven to slow or reverse ... to their physician. This may lead to earlier treatment and better outcomes as well. Aortic stenosis, as ...

  2. Percutaneous Endovascular Recanalization of a Thrombosed Aortic Graft Limb with Stent Placement.

    Science.gov (United States)

    Georgakarakos, Efstratios; Kapoulas, Konstantinos

    2014-06-01

    Common practice in recanalization of a thrombosed prosthetic graft limb in an aortoiliac bypass focuses on balloon-catheter thrombectomy and angiographic exploration followed either by open surgical revision or endovascular management. This report describes the technique of percutaneous endovascular recanalization of an early thrombosed aortic graft limb with stent placement and subsequent restoration of patency and adequate limb perfusion, which remains patent after one year. Percutaneous intervention with stent placement and angioplasty for early graft limb recanalization avoids femoral incisions, and complications or morbidity associated with open surgery, while permitting rapid mobilization of the patient. PMID:26798727

  3. Ballooning mode instability at the plasmapause

    Science.gov (United States)

    Lakhina, G. S.; Mond, M.; Hameiri, E.

    1990-01-01

    The ballooning mode instability, which can excite hydromagnetic waves at the plasmapause, is studied in the presence of azimuthal plasma flows induced during geomagnetically disturbed periods. A general sufficient criterion for the ballooning mode stability is derived, for a change in the potential energy greater than or equal to 0, which involves the integration over an entire field line. A local stability analysis at the equatorial plasmapause region shows that the ballooning modes could be spontaneously generated via instability under at least two conditions: one is similar to the usual interchange condition, and the second to the quasi-interchange modes. Both of these local instability conditions can be derived from the general stability criterion. Finally an exact solution for the equilibrium state with flow is derived analytically, and the change in the potential energy is computed numerically. It is found that, in the cases studied, the flow does not spontaneously excite the ballooning modes; it only further stabilizes (or destabilizes) the ballooning spectrum if originally the system is stable (or unstable). The analysis would be useful for the interpretation of some of the low-frequency modes observed at the ground and near the equatorial plasmapause.

  4. The murine angiotensin II-induced abdominal aortic aneurysm model: rupture risk and inflammatory progression patterns

    Directory of Open Access Journals (Sweden)

    Richard Y Cao

    2010-07-01

    Full Text Available An abdominal aortic aneurysm (AAA is an enlargement of the greatest artery in the body defined as an increase in diameter of 1.5-fold. AAAs are common in the elderly population and thousands die each year from their complications. The most commonly used mouse model to study the pathogenesis of AAA is the angiotensin II (Ang II infusion method delivered via osmotic mini-pump for 28 days. Here, we studied the site-specificity and onset of aortic rupture, characterized three-dimensional (3D images and flow patterns in developing AAAs by ultrasound imaging, and examined macrophage infiltration in the Ang II model using 65 apolipoprotein E deficient mice. Aortic rupture occurred in 16 mice (25 % and was nearly as prevalent at the aortic arch (44 % as it was in the suprarenal region (56 % and was most common within the first seven days after Ang II infusion (12 of 16; 75 %. Longitudinal ultrasound screening was found to correlate nicely with histological analysis and AAA volume renderings showed a significant relationship with AAA severity index. Aortic dissection preceded altered flow patterns and macrophage infiltration was a prominent characteristic of developing AAAs. Targeting the inflammatory component of AAA disease with novel therapeutics will hopefully lead to new strategies to attenuate aneurysm growth and aortic rupture.

  5. Extra-anatomical bypass: a surgical option for recurrent aortic coarctation.

    Science.gov (United States)

    Malaj, Alban; Martinelli, Ombretta; Irace, Francesco Giosue'; Jabbour, Jihad; Gossetti, Bruno; Mazzesi, Giuseppe

    2013-01-01

    Background. Balloon aortoplasty with or without stenting is a less invasive alternative to open surgery for the management of recurrent isthmic coarctation. However, in patients with previous small size tube graft, an open surgical correction is mandatory and, in most cases, an anatomical aortic reconstruction is carried out. Methods. We present the case of a 48-year-old woman with recurrent aortic coarctation and systemic hypertension with systolic value around 190-200 mmHg and preoperative systolic pressure gradient 70 mmHg, submitted to an extra-anatomical bypass. Through a median sternotomy, an extra-anatomical bypass from ascending to descending aorta was performed. Results. No intra- or postoperative complications were observed. The postoperative pressure gradient was 10 mmHg and the systolic pressure ranged from 130 to 140 mmHg. Conclusion. The extra-anatomical bypass can be considered an effective and safe alternative to the anatomical aortic reconstruction in the cases with recurrent aortic coarctation unfit for endovascular treatment.

  6. Extra-Anatomical Bypass: A Surgical Option for Recurrent Aortic Coarctation

    Directory of Open Access Journals (Sweden)

    Alban Malaj

    2013-01-01

    Full Text Available Background. Balloon aortoplasty with or without stenting is a less invasive alternative to open surgery for the management of recurrent isthmic coarctation. However, in patients with previous small size tube graft, an open surgical correction is mandatory and, in most cases, an anatomical aortic reconstruction is carried out. Methods. We present the case of a 48-year-old woman with recurrent aortic coarctation and systemic hypertension with systolic value around 190–200 mmHg and preoperative systolic pressure gradient 70 mmHg, submitted to an extra-anatomical bypass. Through a median sternotomy, an extra-anatomical bypass from ascending to descending aorta was performed. Results. No intra- or postoperative complications were observed. The postoperative pressure gradient was 10 mmHg and the systolic pressure ranged from 130 to 140 mmHg. Conclusion. The extra-anatomical bypass can be considered an effective and safe alternative to the anatomical aortic reconstruction in the cases with recurrent aortic coarctation unfit for endovascular treatment.

  7. Initial Acute Animal Experiment Using a New Miniature Axial Flow Pump in Series With the Natural Heart.

    Science.gov (United States)

    Okamoto, Eiji; Yano, Tetsuya; Shiraishi, Yasuyuki; Miura, Hidekazu; Yambe, Tomoyuki; Mitamura, Yoshinori

    2015-08-01

    We have advocated an axial flow blood pump called "valvo pump" that is implanted at the aortic valve position, and we have developed axial flow blood pumps to realize the concept of the valvo pump. The latest model of the axial flow blood pump mainly consists of a stator, a directly driven impeller, and a hydrodynamic bearing. The axial flow blood pump has a diameter of 33 mm and length of 74 mm, and the length of anatomical occupation is 33 mm. The axial flow blood pump is anastomosed to the aorta with polytetrafluoroethylene (PTFE) cuffs worn on the inflow and outflow ports. Dp-Q curves of the axial flow blood pump are flatter than those of ordinary axial flow pumps, and pump outflow of 5 L/min was obtained against a pressure difference of 50 mm Hg at a rotational speed of 9000 rpm in vitro. The axial flow blood pump was installed in a goat by anastomosing with the thoracic descending aorta using PTFE cuffs, and it was rotated at a rotational speed of 8000 rpm. Unlike in case of the ventricular assistance in parallel with the natural heart, pulsatilities of aortic pressure and aortic flow were preserved even when the pump was on, and mean aortic flow was increased by 1.5 L/min with increase in mean aortic pressure of 30 mm Hg. In conclusion, circulatory assistance in series with the natural heart using the axial flow blood pump was able to improve hemodynamic pulsatility, and it would contribute to improvement of end-organ circulation. . PMID:26234449

  8. The Murine Angiotensin II-Induced Abdominal Aortic Aneurysm Model: Rupture Risk and Inflammatory Progression Patterns

    OpenAIRE

    TimothySt. Amand

    2010-01-01

    An abdominal aortic aneurysm (AAA) is an enlargement of the greatest artery in the body defined as an increase in diameter of 1.5-fold. AAAs are common in the elderly population and thousands die each year from their complications. The most commonly used mouse model to study the pathogenesis of AAA is the angiotensin II (Ang II) infusion method delivered via osmotic mini-pump for 28 days. Here, we studied the site-specificity and onset of aortic rupture, characterized three-dimensional (3D) i...

  9. Near ultraviolet spectrograph for balloon platform

    Science.gov (United States)

    Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    2015-06-01

    Small and compact scientific payloads may be easily designed constructed and own on high altitude balloons. Despite the fact that large orbital observatories provide accurate observations and statistical studies of remote and/or faint space sources, small telescopes on board balloons or rockets are still attractive because of their low cost and rapid response time. We describe here a near ultraviolet (NUV) spectrograph designed to be own on a high{altitude balloon platform. Our basic optical design is a modified Czerny-Turner system using off the shelf optics. We compare different methods of aberration corrections in such a system. We intend the system to be portable and scalable to different telescopes. The use of reflecting optics reduces the transmission loss in UV. We plan on using an image intensified CMOS sensor operating in photon counting mode as the detector of choice.

  10. There is a Text in 'The Balloon'

    DEFF Research Database (Denmark)

    Elias, Camelia

    2009-01-01

    From the Introduction: Camelia Elias' "There is a Text in 'The Balloon': Donald Barthelme's Allegorical Flights" provides its reader with a much-need and useful distinction between fantasy and the fantastic: "whereas fantasy in critical discourse can be aligned with allegory, in which a supernatu......From the Introduction: Camelia Elias' "There is a Text in 'The Balloon': Donald Barthelme's Allegorical Flights" provides its reader with a much-need and useful distinction between fantasy and the fantastic: "whereas fantasy in critical discourse can be aligned with allegory, in which...... York in Donald Barthelme's short story  "The Balloon" from 1968 is discussed in the light of the chapter's epistemological understanding of fantasy....

  11. High altitude balloon experiments at IIA

    Science.gov (United States)

    Nayak, Akshata; Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    Recent advances in balloon experiments as well as in electronics have made it possible to fly scientific payloads at costs accessible to university departments. We have begun a program of high altitude ballooning at the Indian Institute of Astrophysics, Bengaluru. The primary purpose of this activity is to test low-cost ultraviolet (UV) payloads for eventual space flight, but we will also try scientific exploration of the phenomena occurring in the upper atmosphere, including sprites and meteorite impacts. We present the results of the initial experiments carried out at the CREST campus of IIA, Hosakote, and describe our plans for the future.

  12. Cutting balloon angioplasty for intrastent restenosis treatment

    Directory of Open Access Journals (Sweden)

    João Orávio de Freitas Jr

    1999-05-01

    Full Text Available We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA, inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cutting balloon angioplasty using low inflation pressures achieved important luminal gains, in these two cases of intrastent restenosis. Further studies are necessary before the effectiveness of this procedure can be precisely defined.

  13. Acute aortic valve prolapse in Marfan's syndrome.

    OpenAIRE

    Carr, N J; Cullen, S. A.

    1991-01-01

    A 22 year old man with Marfan's syndrome died suddenly following acute aortic valve prolapse. Although aortic root involvement in Marfan's syndrome is common, we have found no previous description of this particular complication in the literature.

  14. Pump impeller

    International Nuclear Information System (INIS)

    A mixed-flow pump impeller, which may be used, for example, as a primary pump for circulating sodium as the primary coolant in a fast nuclear reactor, is described which comprises an impeller with evenly-spaced blades. Some of the blades, which are symmetrically disposed around the axis of rotation of the impeller, extend beyond the ends of the other blades towards the suction side of the pump to form an inducer. The channels defined between the extensions of the extended blades follow helical paths parallel to the axis of rotation. The leading edges of the unextended blades are interposed between the extended blades in the region of divergence of flow from the axis of rotation. The provision of the inducer reduces the risk of cavitation in the pump, which could cause rapid wear of the impeller. A shroud may be provided for the unextended blades. (author)

  15. Particle Astrophysics in NASA's Long Duration Balloon Program

    CERN Document Server

    Gorham, Peter W

    2013-01-01

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons.

  16. Particle Astrophysics in NASA's Long Duration Balloon Program

    International Nuclear Information System (INIS)

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons

  17. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine...

  18. Auditory Risk of Exploding Hydrogen-Oxygen Balloons

    Science.gov (United States)

    Gee, Kent L.; Vernon, Julia A.; Macedone, Jeffrey H.

    2010-01-01

    Although hydrogen-oxygen balloon explosions are popular demonstrations, the acoustic impulse created poses a hearing damage risk if the peak level exceeds 140 dB at the listener's ear. The results of acoustical measurements of hydrogen-oxygen balloons of varying volume and oxygen content are described. It is shown that hydrogen balloons may be…

  19. Increased Production of Sonic Hedgehog by Ballooned Hepatocytes

    OpenAIRE

    Rangwala, Fatima; Cynthia D Guy; Lu, Jiuyi; SUZUKI, Ayako; Burchette, James L.; Abdelmalek, Manal F; Chen, Wei; Diehl, Anna Mae

    2011-01-01

    Ballooned hepatocytes distinguish nonalcoholic steatohepatitis (NASH) from steatosis. Such cells contain dilated endoplasmic reticulum and ubiquitin aggregates, characteristics of endoplasmic reticulum stress. Hepatocyte ballooning increases risk for fibrosis in NASH, suggesting ballooned hepatocytes release pro-fibrogenic factors. Hedgehog ligands function as pro-fibrogenic factors in liver diseases, but mechanisms for Hedgehog ligand production remain poorly understood. We evaluated the hyp...

  20. ABDOMINAL AORTIC ANEURYSM (AAA

    Directory of Open Access Journals (Sweden)

    Rajesh G

    2011-11-01

    Full Text Available AAA is defined as a distension of the infrarenal aorta by more than 50% (or 1.5 times compared with a corresponding healthy, aged and gender matched population. AAA afflicts 1 to 6 % of the general population aged more than 60 years and the incidence rises by approximately 0.15% annually. When the definition of a maximum external diameter ≥3 cm is used, the prevalence of AAA is upto 6 times greater in men than in women. AAAs are much more common than thoracic aortic aneurysms. Most common cause of AAA is atherosclerosis (95%. Less common causes include infectious or inflammatory origin or those associated with connective tissue disorders. Process of AAA formation is multifactorial. Other than the general risk factors for atherosclerosis, genetic predispo s iti on, aut o immunity and hemodynamic factors all play roles in its formation. AAA is 1.5 times more frequent in hypert ensive patients. Smokers have 8 times risk for developing AAA. The existence of familial aggre gation of AAA implicates genetic factors in the etiology of AAA. Women with AAA are more likely to have a positive family history of this disorder. Those with a family history of AAA have an increased risk of 30%, and their aneurysms tend to occur at a younger age and carry a greater risk of rupture than do sporadic aneurysms.

  1. Abdominal aortic feminism.

    Science.gov (United States)

    Mortimer, Alice Emily

    2014-01-01

    A 79-year-old woman presented to a private medical practice 2 years previously for an elective ultrasound screening scan. This imaging provided the evidence for a diagnosis of an abdominal aortic aneurysm (AAA) to be made. Despite having a number of recognised risk factors for an AAA, her general practitioner at the time did not follow the guidance set out by the private medical professional, that is, to refer the patient to a vascular specialist to be entered into a surveillance programme and surgically evaluated. The patient became symptomatic with her AAA, was admitted to hospital and found to have a tender, symptomatic, 6 cm leaking AAA. She consented for an emergency open AAA repair within a few hours of being admitted to hospital, despite the 50% perioperative mortality risk. The patient spent 4 days in intensive care where she recovered well. She was discharged after a 12 day hospital stay but unfortunately passed away shortly after her discharge from a previously undiagnosed gastric cancer.

  2. Open aortic surgery after thoracic endovascular aortic repair.

    Science.gov (United States)

    Coselli, Joseph S; Spiliotopoulos, Konstantinos; Preventza, Ourania; de la Cruz, Kim I; Amarasekara, Hiruni; Green, Susan Y

    2016-08-01

    In the last decade, thoracic endovascular aortic aneurysm repair (TEVAR) has emerged as an appealing alternative to the traditional open aortic aneurysm repair. This is largely due to generally improved early outcomes associated with TEVAR, including lower perioperative mortality and morbidity. However, it is relatively common for patients who undergo TEVAR to need a secondary intervention. In select circumstances, these secondary interventions are performed as an open procedure. Although it is difficult to assess the rate of open repairs after TEVAR, the rates in large series of TEVAR cases (>300) have ranged from 0.4 to 7.9 %. Major complications of TEVAR that typically necessitates open distal aortic repair (i.e., repair of the descending thoracic or thoracoabdominal aorta) include endoleak (especially type I), aortic fistula, endograft infection, device collapse or migration, and continued expansion of the aneurysm sac. Conversion to open repair of the distal aorta may be either elective (as for many endoleaks) or emergent (as for rupture, retrograde complicated dissection, malperfusion, and endograft infection). In addition, in select patients (e.g., those with a chronic aortic dissection), unrepaired sections of the aorta may progressively dilate, resulting in the need for multiple distal aortic repairs. Open repairs after TEVAR can be broadly classified as full extraction, partial extraction, or full salvage of the stent-graft. Although full and partial stent-graft extraction imply failure of TEVAR, such failure is generally absent in cases where the stent-graft can be fully salvaged. We review the literature regarding open repair after TEVAR and highlight operative strategies.

  3. Clinical experience with the Sarns centrifugal pump.

    Science.gov (United States)

    Curtis, J J; Walls, J T; Demmy, T L; Boley, T M; Schmaltz, R A; Goss, C F; Wagner-Mann, C C

    1993-07-01

    Since October 1986, we have had experience with 96 Sarns centrifugal pumps in 72 patients (pts). Heparinless left atrial to femoral artery or aorta bypass was used in 14 pts undergoing surgery on the thoracic aorta with 13 survivors (93%). No paraplegia or device-related complications were observed. In 57 patients, the Sarns centrifugal pump was used as a univentricular (27 pts) or biventricular (30 pts) cardiac assist device for postcardiotomy cardiogenic shock. In these patients, cardiac assist duration ranged from 2 to 434 h with a hospital survival rate of 29% in those requiring left ventricular assist and 13% in those requiring biventricular assist. Although complications were ubiquitous in this mortally ill patient population, in 5,235 pump-hours, no pump thrombosis was observed. Hospital survivors followed for 4 months to 6 years have enjoyed an improved functional class. We conclude that the Sarns centrifugal pump is an effective cardiac assist device when used to salvage patients otherwise unweanable from cardiopulmonary bypass. Partial left ventricular bypass using a centrifugal pump has become our procedure of choice for unloading the left ventricle and for maintenance of distal aortic perfusion pressure when performing surgery on the thoracic aorta. This clinical experience with the Sarns centrifugal pump appears to be similar to that reported with other centrifugal assist devices.

  4. Single-balloon versus double-balloon bipedicular kyphoplasty for osteoporotic vertebral compression fractures.

    Science.gov (United States)

    Wang, Heng; Sun, Zhenzhong; Wang, Zhiwen; Jiang, Weimin

    2015-04-01

    Twenty-eight patients with osteoporotic vertebral compression fractures (OVCF) were treated with single-balloon bipedicular kyphoplasty (Group A), and 40 patients were treated with double-balloon bipedicular kyphoplasty (Group B). Visual Analogue Scale (VAS) score, vertebral height, and kyphotic angle (KA) were evaluated pre-operatively, post-operatively (3 days after surgery) and at final follow-up. Operative time, X-ray exposure frequency and costs were recorded. The mean operative time and X-ray exposure frequency in Group A were greater than in Group B (pkyphoplasty is a safe and cost-effective surgical method for the treatment of OVCF. It can achieve pain relief comparable with double-balloon bipedicular kyphoplasty. However, double-balloon bipedicular kyphoplasty is more efficacious in terms of the restoration of vertebral height and reduction of KA, and the operative time and X-ray exposure frequency are lower.

  5. Survey of balloon design problems and prospects for large super-pressure balloons in the next century

    Science.gov (United States)

    Yajima, Nobuyuki

    About a half century has passed since modern scientific ballooning started in the 1950's. All this while, size and payload capabilities of zero-pressure balloons have improved rapidly. On the other hand, a super-pressure balloon which can take the place of a conventional large zero-pressure balloon has not yet become operational. To investigate this problem, previous research on balloon design is surveyed. It is concluded that quite important design problems have been left unsolved. Problems occur when a load tape assembly is introduced to the natural shape balloon system. The author proposed a new balloon design concept, named 3-D gore design, at the last COSPAR held in Nagoya in 1998. This theory improves the conventional natural shape design concept for the balloon reinforced by load tapes. This new design concept enables enhancing the strength of a balloon dramatically. In addition, the strength does not depend on balloon size. This theory will accelerate the development of large super-pressure balloons which will play a leading role in scientific ballooning in the 21st century.

  6. Vancouver Transcatheter Aortic Valve Replacement Clinical Pathway: Minimalist Approach, Standardized Care, and Discharge Criteria to Reduce Length of Stay.

    Science.gov (United States)

    Lauck, Sandra B; Wood, David A; Baumbusch, Jennifer; Kwon, Jae-Yung; Stub, Dion; Achtem, Leslie; Blanke, Philipp; Boone, Robert H; Cheung, Anson; Dvir, Danny; Gibson, Jennifer A; Lee, Bobby; Leipsic, Jonathan; Moss, Robert; Perlman, Gidon; Polderman, Jopie; Ramanathan, Krishnan; Ye, Jian; Webb, John G

    2016-05-01

    We describe the development, implementation, and evaluation of a standardized clinical pathway to facilitate safe discharge home at the earliest time after transfemoral transcatheter aortic valve replacement. Between May 2012 and October 2014, the Heart Team developed a clinical pathway suited to the unique requirements of transfemoral transcatheter aortic valve replacement in contemporary practice. The components included risk-stratified minimalist periprocedure approach, standardized postprocedure care with early mobilization and reconditioning, and criteria-driven discharge home. Our aim was to reduce variation in care, identify a subgroup of patients suitable for early discharge (≤48 hours), and decrease length of stay for all patients. We addressed barriers related to historical practices, complex multidisciplinary stakeholder engagement, and adoption of length of stay as a quality indicator. We retrospectively reviewed the experiences of 393 consecutive patients; 150 (38.2%) were discharged early. At baseline, early discharge patients had experienced less previous balloon aortic valvuloplasty, had higher left ventricular ejection fraction, better cognitive function, and were less frail than the standard discharge group (>48 hours). Early discharge was associated with the use of local anesthesia, implantation of balloon expandable device, avoidance of urinary catheter, and early removal of temporary pacemaker. Median length of stay was 1 day for early discharge and 3 days for other patients; 97.7% were discharged home. There were no differences in 30-day mortality (1.3%), disabling stroke (0.8%), or readmission (10.7%). The implementation of a transcatheter aortic valve replacement clinical pathway shifted the program's approach to combine standardized processes and individual risk stratification. The Vancouver transcatheter aortic valve replacement clinical pathway requires a rigorous assessment to determine its efficacy, safety, and reproducibility. PMID

  7. Attitude determination for balloon-borne experiments

    Science.gov (United States)

    Gandilo, N. N.; Ade, P. A. R.; Amiri, M.; Angilè, F. E.; Benton, S. J.; Bock, J. J.; Bond, J. R.; Bryan, S. A.; Chiang, H. C.; Contaldi, C. R.; Crill, B. P.; Devlin, M. J.; Dober, B.; Doré, O. P.; Farhang, M.; Filippini, J. P.; Fissel, L. M.; Fraisse, A. A.; Fukui, Y.; Galitzki, N.; Gambrel, A. E.; Golwala, S.; Gudmundsson, J. E.; Halpern, M.; Hasselfield, M.; Hilton, G. C.; Holmes, W. A.; Hristov, V. V.; Irwin, K. D.; Jones, W. C.; Kermish, Z. D.; Klein, J.; Korotkov, A. L.; Kuo, C. L.; MacTavish, C. J.; Mason, P. V.; Matthews, T. G.; Megerian, K. G.; Moncelsi, L.; Morford, T. A.; Mroczkowski, T. K.; Nagy, J. M.; Netterfield, C. B.; Novak, G.; Nutter, D.; O'Brient, R.; Pascale, E.; Poidevin, F.; Rahlin, A. S.; Reintsema, C. D.; Ruhl, J. E.; Runyan, M. C.; Savini, G.; Scott, D.; Shariff, J. A.; Soler, J. D.; Thomas, N. E.; Trangsrud, A.; Truch, M. D.; Tucker, C. E.; Tucker, G. S.; Tucker, R. S.; Turner, A. D.; Ward-Thompson, D.; Weber, A. C.; Wiebe, D. V.; Young, E. Y.

    2014-07-01

    An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of Spider, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. In the 2010 and 2012 BLASTPol flights from McMurdo Station, Antarctica, the system demonstrated an accuracy of < 5' rms in-flight, and < 5" rms post-flight.

  8. Treatment of tuberculous bronchostenosis: balloon bronchoplasty

    International Nuclear Information System (INIS)

    The purpose of this study is to evaluate the efficacy of the balloon bronchoplasty in the treatment of the tuberculous bronchostenosis. Balloon bronchoplasty was performed in thirteen patients with stenosis of the left main bronchus (two with combined left upper and lower lobar bronchostenosis) using a inflatable balloon catheter under a fluoroscopic guide. We analysed the changes in the severity of dyspnea and wheezing, serial FEV1/FVC as a parameter of the airflow obstruction, and bronchial diameter and lung volume on chest radiographs. The extent of pulmonary tuberculosis was correlated with the improvement of FEV1/ FVC. There was an improvement of dyspnea in 69% (9/13), decrease of wheezing in 69% (9/13), significant increase of FEV1/FVC in 18% (2/11). The increase of the bronchial diameter and lung volume were seen in 84% (11/13) and 53% (7/13), respectively. The significant increase of FEV1/FVC was seen in 28% (2/7) of the patients with lung involvement of tuberculous less than one third of left upper lobe, whereas there was no increase in those of more than one third. The was no complication except transient leukocytosis, fever and blood-tinged sputum. In conclusion, balloon bronchoplasty is effective in the treatment of medically intractable tuberculous bronchostenosis, and can be considered as an initial method of treatment

  9. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    Science.gov (United States)

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR. PMID:27295772

  10. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    Science.gov (United States)

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR.

  11. 78 FR 36702 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems (IABP) for...

    Science.gov (United States)

    2013-06-19

    ... myocardial infarction (MI) and cardiogenic shock, which include the use of percutaneous coronary intervention...) demonstrated that the mortality of patients with cardiogenic shock was 30.7 percent, which was low compared to other cardiogenic shock trials, and has been cited as evidence of a benefit from IABP use....

  12. Measurements of gondola motion on a stratospheric balloon flight

    CERN Document Server

    Safonova, Margarita; Sreejith, A G; Sarpotdar, Mayuresh; Ambily, S; Prakash, Ajin; Mathew, Joice; Murthy, Jayant; Anand, Devarajan; Kapardhi, B V N; Kumar, B Suneel; Kulkarni, P M

    2016-01-01

    Balloon experiments are an economically feasible method of conducting observations in astronomy that are not possible from the ground. The astronomical payload may include a telescope, a detector, and a pointing/stabilization system. Determining the attitude of the payload is of primary importance in such applications, to accurately point the detector/telescope to the desired direction. This is especially important in generally unstable lightweight balloon flights. However, the conditions at float altitudes, which can be reached by zero pressure balloons, could be more stable, enabling accurate pointings. We have used the Inertial Measurement Unit (IMU), placed on a stratospheric zero pressure balloon, to observe 3-axis motion of a balloon payload over a fight time of 4.5 hours, from launch to the float altitude of 31.2 km. The balloon was launched under nominal atmospheric conditions on May 8th 2016, from a Tata Institute of Fundamental Research Balloon Facility, Hyderabad.

  13. Primary stenting in the treatment of focal atherosclerotic abdominal aortic stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, W.; Falkowski, A.; Garncarek, J.; Karasek, M.; England, S.; Zawierucha, D

    2006-08-15

    Aim: To evaluate the results of primary stent placement in focal atherosclerotic aortic stenoses using balloon expandable stents. Materials and methods: Twenty-six primary balloon expandable stent placements in the abdominal aorta were performed and reviewed. All the aortic stenoses were atherosclerotic. Patients were followed up by ankle/brachial pressure indices (ABPI) and Doppler ultrasound (US) at 24 h after procedure and at 12 and 24 months. Follow-up angiograms were performed at 12 months. Results: Twenty-six stents in 26 patients were placed in the infrarenal aorta. All procedures were technically successful and immediate clinical success was obtained. The mean ABPI significantly improved from 0.52 {+-} 0.10 to 0.94 {+-} 0.09 within 24 h after procedure, and remained at 0.90 {+-} 0.12 between 12 and 24 months follow-up (mean 18 months). There was full haemodynamic success at hospital discharge and at 12 and 24 months after the procedure. Clinical success at 12 and 24 months (mean 18 months) was defined as an improvement in the Fontaine classification by at least one class compared with the pre-procedure class and was shown to be 100%. Conclusion: In summary, we report that primary stenting is a safe and effective alternative to surgery in cases of symptomatic stenosis of the infrarenal abdominal aorta. The excellent intermediate term results suggested that we would recommend primary stenting as the treatment of choice for focal atherosclerotic stenoses of the infrarenal aorta in selected patients.

  14. Using The Descending Aortic Wall Thickness Measured In Transesophageal Echocardiography As A Risk Marker For Aortic Dissection

    OpenAIRE

    Zaher Fanari; Sumaya Hammami; Muhammad Baraa Hammami; Safa Hammami; Chete Eze-Nliam; Weintraub, William S.

    2015-01-01

    Objective: The aim of this study is to estimate whether aortic wall thickness is increased in patients with Aortic dissection (AD) compared to low risk control group and can be used in addition to aortic diameter as a risk marker of AD. Background: AD occurs due to pathologies that may increase thickness of the aortic wall. Transesophageal echocardiography (TEE) has the ability to visualise both the thoracic aortic wall and lumen. Aortic diameter has been used to predict aortic dissection...

  15. Insulin pumps.

    Science.gov (United States)

    Pickup, J

    2011-02-01

    The last year has seen a continued uptake of insulin pump therapy in most countries. The USA is still a leader in pump use, with probably some 40% of type 1 diabetic patients on continuous subcutaneous insulin infusion (CSII), but the large variation in usage within Europe remains, with relatively high use (> 15%) in, for example, Norway, Austria, Germany and Sweden and low use (companies or funding from national health services, the availability of sufficient diabetes nurse educators and dietitians trained in pump procedures, and clear referral pathways for the pump candidate from general practitioner or general hospital to specialist pump centre. There are now several comprehensive national guidelines on CSII use (see ATTD Yearbook 2009) but more work needs to be done in unifying uptake and ensuring all those who can benefit do so. Technology developments recently include increasing use of pumps with continuous glucose monitoring (CGM) connectivity (see elsewhere in this volume) and the emergence of numerous manufacturers developing so-called 'patch pumps', often for the type 2 diabetes market. Interestingly, the evidence base for CSII in this group is not well established, and for this reason the selected papers on CSII in this section include several in this area. The use of CSII in diabetic pregnancy is a long-established practice, in spite of the lack of evidence that it is superior to multiple daily injections (MDI), and few randomised controlled trials have been done in recent years. Several papers in this field this year continue the debate about the usefulness of CSII in diabetic pregnancy and are reviewed here. It is pleasing to see more research on the psychosocial aspects of CSII during the year, both from the point of view of how psychological beliefs influence outcomes on CSII (is there a type of patient who does particularly well or poorly on CSII?) and how CSII affects psychological factors like mood, behaviour and quality of life. Quality of

  16. Spectrum of Aortic Valve Abnormalities Associated with Aortic Dilation Across Age Groups in Turner Syndrome

    Science.gov (United States)

    Olivieri, Laura J.; Baba, Ridhwan Y.; Arai, Andrew E.; Bandettini, W. Patricia; Rosing, Douglas R.; Bakalov, Vladimir; Sachdev, Vandana; Bondy, Carolyn A.

    2014-01-01

    Background Congenital aortic valve fusion is associated with aortic dilation, aneurysm and rupture in girls and women with Turner syndrome (TS). Our objective was to characterize aortic valve structure in subjects with TS, and determine the prevalence of aortic dilation and valve dysfunction associated with different types of aortic valves. Methods and Results The aortic valve and thoracic aorta were characterized by cardiovascular magnetic resonance imaging in 208 subjects with TS in an IRB-approved natural history study. Echocardiography was used to measure peak velocities across the aortic valve, and the degree of aortic regurgitation. Four distinct valve morphologies were identified: tricuspid aortic valve (TAV) 64%(n=133), partially fused aortic valve (PF) 12%(n=25), bicuspid aortic valve (BAV) 23%(n=47), and unicuspid aortic valve (UAV) 1%(n=3). Age and body surface area (BSA) were similar in the 4 valve morphology groups. There was a significant trend, independent of age, towards larger BSA-indexed ascending aortic diameters (AADi) with increasing valve fusion. AADi were (mean +/− SD) 16.9 +/− 3.3 mm/m2, 18.3 +/− 3.3 mm/m2, and 19.8 +/− 3.9 mm/m2 (p<0.0001) for TAV, PF and BAV+UAV respectively. PF, BAV, and UAV were significantly associated with mild aortic regurgitation and elevated peak velocities across the aortic valve. Conclusions Aortic valve abnormalities in TS occur with a spectrum of severity, and are associated with aortic root dilation across age groups. Partial fusion of the aortic valve, traditionally regarded as an acquired valve problem, had an equal age distribution and was associated with an increased AADi. PMID:24084490

  17. Review of reported causes of device embolization following trans-catheter aortic valve implantation.

    Science.gov (United States)

    Ibebuogu, Uzoma N; Giri, Smith; Bolorunduro, Oluwaseyi; Tartara, Paolo; Kar, Saibal; Holmes, David; Alli, Oluseun

    2015-06-15

    Transcatheter heart valve (THV) embolization is a rare but serious complication of transcatheter aortic valve implantation. Studies, including case reports, case series, and original reports published between 2002 and 2013, with regard to THV embolization were identified with a systemic electronic search using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. A total of 19 publications describing 71 patients were identified. Most patients (64%) were men, with a mean age of 80 ± 6 years and a mean logistic European System for Cardiac Operative Risk Evaluation score of 22.4 ± 9.3%. Balloon-expandable valves were used in 72% of the patients. The reported transcatheter aortic valve replacement access site was transfemoral in 80% of patients. Most cases (90%) occurred <1 hour after implantation, whereas 10% had late embolization (range 4 hours to 43 days). The most common site of embolization was the ascending aorta (38%), followed by the left ventricle (31%), descending aorta (23%), and aortic arch (8%). Open-heart surgery was required in 28% for valve retrieval and replacement. The 30-day stroke and mortality rates were 11% and 17%, respectively. Ventricular embolization and urgent conversion to open-heart surgery were significantly associated with death during hospitalization (p = 0.017 and p = 0.029, respectively). Likely causes of embolization were identified in 59 patients, with positioning error as the most commonly reported (47%), followed by pacing error (13%). In conclusion, THV embolization occurred early after transcatheter aortic valve implantation. The ascending aorta was the most common site of embolization. Higher 30-day stroke and mortality rates were associated with THV embolization compared with most published series of transcatheter aortic valve implantation outcomes. PMID:25882773

  18. Single center experience in endovascular aortic repair: review of technical and clinical aspects

    Directory of Open Access Journals (Sweden)

    Sinan Demirtaş

    2014-09-01

    Full Text Available Objective: The aim of this study is sharing of our endovascular aortic repair experiments in patients with high risk for surgery and contributing to literature with comparing previous report according to mortality complicationsand additional operations. Methods:Patients with endovascular aortic repair application were evaluated retrospectively. Perioperative one month mortality, additional applications during procedure, occurred complications, endoleak types, approaching anesthetical technique, diagnosis of disease, comorbid factors and demographical data registered. Results were compared with data in the literature Results: Abdominal endovascular aortic repair (EVAR applicated into 19 patients. Thoracic endovascular aor tic repair (TEVAR applicated into 11 patients. EVAR patients were operated with diagnosis of abdominal aortic aneurysm. Nine of these patients were emergely operated due to rupture. TEVAR applicated 8 patients were operated due to Type 3 Aortic Dissection and 1 patient was operated due to transsection. One month mortality of all patients were found as 10% (three atients. Endoleaks were occurred 6 patients: Three of them were Type 1a, two of them were Type1b and one of them was Type2. Balloon angioplasty applicated in two patients due to Type 1a endoleak and, in one patient due to Type 1b endoleak. Chronic renal failure was developed in one patient (3.3% due to contrast nephropathy. Reexploration was applicated in two patients (6.7% due to hematoma. Conclusion: Endovascular techniques are become frequently preferred treatment modality with the developing technology. We believed that endovascular approaches are safely preferable alternative in patients with high surgical risk as our series.

  19. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... more likely we see aortic stenosis. Again, patient education is part of the evaluation and management of ... want to embrace less invasive or more progressive technology, you want to make ... with that information and certainly shouldn't be insulted by that. ...

  20. Minimally Invasive Aortic Valve Replacement

    Medline Plus

    Full Text Available ... well. I want to underscore again that exercise testing is really not recommended in patient with classic symptoms in severe aortic stenosis, as it's probably more stress than the patient's heart should have to undergo. Once again, serial evaluations, as with any chronic disease process, are ...

  1. Whole blood pumping with a microthrottle pump

    OpenAIRE

    Davies, M J; Johnston, I. D.; Tan, C. K. L.; Tracey, M. C.

    2010-01-01

    We have previously reported that microthrottle pumps (MTPs) display the capacity to pump solid phase suspensions such as polystyrene beads which prove challenging to most microfluidic pumps. In this paper we report employing a linear microthrottle pump (LMTP) to pump whole, undiluted, anticoagulated, human venous blood at 200 μl min−1 with minimal erythrocyte lysis and no observed pump blockage. LMTPs are particularly well suited to particle suspension transport by virtue of their relatively ...

  2. Decreased expression of fibulin-4 in aortic wall of aortic dissection.

    Science.gov (United States)

    Huawei, P; Qian, C; Chuan, T; Lei, L; Laing, W; Wenlong, X; Wenzhi, L

    2014-02-01

    In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10 patients operated for acute ascending aortic dissection and five patients for chronic ascending aortic dissection. Another 15 pieces of samples from patients who had coronary artery bypass were as controls. The aortic samples were stained with aldehyde magenta dyeing to evaluate the arrangement of elastic fibers. The Fibulin-4 protein and mRNA expression were both determined by Western blot and realtime quantitative polymerase chain reaction. Compared with the control group, both in acute and chronic ascending aortic dissection, elastic fiber fragments increased and the expression of fibulin-4 protein significantly decreased (P= 0.045 < 0.05). The level of fibulin-4 mRNA decreased in acute ascending aortic dissection (P= 0.034 < 0.05), while it increased in chronic ascending aortic dissection (P=0.004 < 0.05). The increased amounts of elastic fiber fragments were negatively correlated with the expression of fibulin-4 mRNA in acute ascending aortic dissection. In conclusion, in aortic wall of ascending aortic dissection, the expression of fibulin-4 protein decreased and the expression of fibulin-4 mRNA was abnormal. Fibulin-4 may play an important role in the pathogenesis of aortic dissection.

  3. Balloon-borne gamma-ray polarimetry

    CERN Document Server

    Pearce, Mark

    2011-01-01

    The physical processes postulated to explain the high-energy emission mechanisms of compact astrophysical sources often yield polarised soft gamma rays (X-rays). PoGOLite is a balloon-borne polarimeter operating in the 25-80 keV energy band. The polarisation of incident photons is reconstructed using Compton scattering and photoelectric absorption in an array of phoswich detector cells comprising plastic and BGO scintillators, surrounded by a BGO side anticoincidence shield. The polarimeter is aligned to observation targets using a custom attitude control system. The maiden balloon flight is scheduled for summer 2011 from the Esrange Space Centre with the Crab and Cygnus X-1 as the primary observational targets.

  4. Using a Breast Pump

    Science.gov (United States)

    ... you can relax and not be disturbed while pumping. If you have an electric pump, find an ... otherwise irritating your nipple or breast tissue. Begin Pumping If your pump is electric or battery-powered, ...

  5. Revascularização da artéria marginal com uso da artéria torácica interna direita pediculada retroaórtica sem circulação extracorpórea Off-pump grafting of the circumflex artery with pedicled retro-aortic right internal thoracic artery graft

    Directory of Open Access Journals (Sweden)

    Walter J. Gomes

    2005-03-01

    , improving survival. We present the technique of OPCAB using both pedicled ATI grafts, with the right ITA (RITA routed retro-aortic through the transverse sinus, to revascularize the branches of the circumflex artery (Cx. METHOD: Twenty-six patients, who underwent OPCAB with bilateral ATI grafts, were studied, where the left ATI (LITA was used to revascularize the left anterior descending artery (LAD and the pedicled RITA, routed through the transverse sinus and anastomosed to the branches of the Cx. Twenty-one patients were male and five female, the age ranging between 42 and 74 years. The morbidities observed in this cohort were previous myocardial infarction in 18 (69% patients, diabetes mellitus in 10 (38%, renal failure in four (7.7% and AIDS in one (3.8% patient. RESULTS: No patient presented ECG changes or enzymatic increases in the postoperative period. The grafts per patient varied from two to four (average 3.0 grafts/patient. No cases of sternal infection or dehiscence were observed. One patient had a stroke on the 4º postoperative day and died. The postoperative hospital stay varied between 3 to 12 days (average 5.8±2.0 days. No late deaths or cardiovascular events were recorded. CONCLUSIONS: This technique makes off-pump grafting of the circumflex artery branches using the pedicled RITA possible and potentially enhances the benefits of coronary artery bypass surgery.

  6. Pneumothorax, music and balloons: A case series

    OpenAIRE

    2013-01-01

    We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of ...

  7. Coronary artery dissection by an oversized balloon.

    Science.gov (United States)

    Yafi, Wael; Jacquemin, Laurent

    2014-01-01

    Percutaneous coronary intervention (PCI) as a treatment of coronary artery disease can be a simple, rapid procedure with a clear benefit for the patient, but it could also become a complex procedure with fatal consequences. These complications depend on the lesion itself, material used and also on operating staff. In this case we report a coronary artery dissection of the circumflex (CX) artery caused by inflation of an oversized balloon. We discuss here the management and evolution of this complication. PMID:25479753

  8. Double balloon enteroscopy examinations in general anesthesia

    Institute of Scientific and Technical Information of China (English)

    Laszlo; Zubek; Lena; Szabo; Peter; Laszlo; Lakatos; Janos; Papp; Janos; Gal; Gabor; Elo

    2010-01-01

    AIM:To demonstrate that the double balloon enteroscopy(DBE) can be safely performed in general anesthesia with intubation.METHODS:We performed a retrospective examination between August 2005 and November 2008 amongpatients receiving intubation narcosis due to DBE examination.The patients were grouped based on sex,age and physical status.Anesthesia records includedduration of anesthesia,quantity of medication usedand anesthesia-related complications.We determinedthe frequency of complications in the differen...

  9. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  10. Lightweight Reusable Solar Array For Balloons

    Science.gov (United States)

    Aaron, K.; Tensor, P.; Nock, K.; Wyszkowski, C.

    We will discuss a new lightweight reusable solar array system, dubbed HighPower, which is being developed for the Ultra-Long Duration Balloon (ULDB) program using NASA/SBIR funding, but which is also applicable to other balloon systems. The system uses a vertically deployed stack of panels suspended from their corners by cables. The stack act likes a two-dimensional Venetian blind. By raising and lowering opposite corners, the array of parallel panels can be pointed over most of the upper hemisphere. This allows the panels to remain normal to the sun despite the slow rotation of the gondola and without requiring rotation of the system (no slip rings) or heavy cantilevered rotation joints. The system is sized to generate 2000 W using six 2m x 2m panels. The modularity of the system allows panels to be added or removed to tailored the power to the needs of the mission. Prior to cut -down of the balloon, the panels can be retracted and stowed compactly in the lower part of the gondola. This will protect the array during landing, allowing the array to be reused on subsequent flights.

  11. Transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis: a meta analysis

    Institute of Scientific and Technical Information of China (English)

    WU Yi-cheng; ZHANG Jian-feng; SHEN Wei-feng; ZHAO Qiang

    2013-01-01

    Background Transcatheter aortic valve implantation (TAVI) has emerged as the treatment choice for non-operable patients with severe symptomatic aortic stenosis (AS) and may be a good alternative to surgery for those at very high or prohibitive surgical risk.We performed a meta-analysis to evaluate the comparative benefits of TAVI versus surgical aortic valve replacement (SAVR) in patients with severe AS.Methods A comprehensive literature search of PubMed,Embase,ScienceDirect and Cochrane Central Register of Controlled trials was performed,and randomized trials as well as cohort studies with propensity score analysis were included.Results One randomized trial (n=699) and six retrospective cohort studies (n=781) were selected for meta-analysis.Mortality at 30-day and 1-year follow-up was comparable between TAVI and SAVR.Despite similar incidences of stroke,myocardial infarction,re-operation for bleeding,and renal failure requiring dialysis,TAVI was associated with a lower occurrence rate of new-onset atrial fibrillation (OR 0.51,95% CI 0.33-0.78) and shorter procedural time (mean difference -67.50 minutes,95% CI-87.20 to-47.81 minutes).Post-operative aortic regurgitation and permanent pacemaker implantation were more common in patients after TAVI than in those with SAVR (OR 5.53,95% CI 3.41-8.97; OR 1.71,95% Cl 1.02-2.84,respectively).Conclusion In patients with severe symptomatic AS,TAVI and SAVR did not differ with respect to short-and mid-term survival,but the incidence of permanent pacemaker implantation and post-procedural aortic regurgitation remain relatively high after TAVI.

  12. Design of a cost-effective, hemodynamically adjustable model for resuscitative endovascular balloon occlusion of the aorta (REBOA) simulation.

    Science.gov (United States)

    Keller, Benjamin A; Salcedo, Edgardo S; Williams, Timothy K; Neff, Lucas P; Carden, Anthony J; Li, Yiran; Gotlib, Oren; Tran, Nam K; Galante, Joseph M

    2016-09-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an adjunct technique for salvaging patients with noncompressible torso hemorrhage. Current REBOA training paradigms require large animals, virtual reality simulators, or human cadavers for acquisition of skills. These training strategies are expensive and resource intensive, which may prevent widespread dissemination of REBOA. We have developed a low-cost, near-physiologic, pulsatile REBOA simulator by connecting an anatomic vascular circuit constructed out of latex and polyvinyl chloride tubing to a commercially available pump. This pulsatile simulator is capable of generating cardiac outputs ranging from 1.7 to 6.8 L/min with corresponding arterial blood pressures of 54 to 226/14 to 121 mmHg. The simulator accommodates a 12 French introducer sheath and a CODA balloon catheter. Upon balloon inflation, the arterial waveform distal to the occlusion flattens, distal pulsation within the simulator is lost, and systolic blood pressures proximal to the balloon catheter increase by up to 62 mmHg. Further development and validation of this simulator will allow for refinement, reduction, and replacement of large animal models, costly virtual reality simulators, and perfused cadavers for training purposes. This will ultimately facilitate the low-cost, high-fidelity REBOA simulation needed for the widespread dissemination of this life-saving technique. PMID:27270855

  13. Metabolic and hemodynamic effects of saline infusion to maintain volemia on temporary abdominal aortic occlusion

    Directory of Open Access Journals (Sweden)

    Fábio Ferreira Amorim

    2002-10-01

    Full Text Available OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10 and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10. All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

  14. Indexing aortic valve area by body surface area increases the prevalence of severe aortic stenosis

    DEFF Research Database (Denmark)

    Jander, Nikolaus; Gohlke-Bärwolf, Christa; Bahlmann, Edda;

    2014-01-01

    To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are......To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are...

  15. Congenital aortic regurgitation in a child with a tricuspid non-stenotic aortic valve.

    OpenAIRE

    Hashimoto, R; Miyamura, H; Eguchi, S

    1984-01-01

    After follow up for seven years a 10 year old boy with congenital aortic regurgitation was found to have a tricuspid non-stenotic aortic valve at operation. The right coronary cusp was dysplastic, thickened, and contracted; the gap between its free margin and aortic wall was bridged with two fibrous bands; and the left coronary and non-coronary cusps were almost normal. The aortic valve was replaced with a prosthesis (St Jude Medical No 23), and the postoperative course was uneventful.

  16. Aortopathy in patients with a bicuspid aortic valve : determining susceptibility for aortic complications

    NARCIS (Netherlands)

    Grewal, Nimrat

    2015-01-01

    The prevalence of aortic dilation and related complications as rupture and dissection is higher in patients with a bicuspid aortic valve (BAV) as compared to patients with a tricuspid aortic valve (TAV), although not every individual carries this increased risk. It is therefore essential to identify

  17. The Efficacy of Autologous Femoropopliteal Vein Reconstruction for Primary Aortic and Aortic Graft Infection

    NARCIS (Netherlands)

    Dirven, M.; Jagt, M.F.P. van der; Barendregt, W.B.; Vliet, D. van der

    2015-01-01

    BACKGROUND: The objective of our study was to analyze the efficacy of autologous superficial femoropopliteal vein reconstruction for primary aortic or aortic graft infection. METHODS: We performed a retrospective analysis of 14 patients treated for an infected aortic prosthesis or primary infected a

  18. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  19. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav;

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  20. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav;

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  1. MARFAN SYNDROME AND QUADRICUSPID AORTIC VALVE

    OpenAIRE

    Sürücü, Hüseyin; ÇİMEN, Sadi

    2013-01-01

    ABSTRACTWhile the major cardiovascular manifestation in Marfan syndrome is a progressive dilatation of the ascending aorta, leading to aortic aneurysm formation and eventually to fatal aortic rupture or dissection, mitral valve prolapse and calcification of the mitral valve annulus, dilatation of the main pulmonary artery may be seen. There was no knowledge about the association of Marfan syndrome and quadricuspid aortic valve. In this case report, we aimed to declare this association between...

  2. Transcatheter Aortic Valve Replacement in a Nonagenarian

    OpenAIRE

    Kneitz, Abby; Clifton, William; Kar, Biswajit; Delgado, Reynolds M.

    2013-01-01

    Approximately 30% to 40% of elderly patients with severe, symptomatic aortic valve stenosis are deemed ineligible for surgery because of high perioperative risk. We describe the use of an alternative transfemoral approach known as transcatheter aortic valve implantation in a nonagenarian patient with severe aortic stenosis. Our patient recovered successfully, and by the time of her most recent follow-up visit, 7 months after the procedure, she had regained a substantial degree of function. Th...

  3. Fluoroscopically Guided Balloon Dilation for Postintubation Tracheal Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woong Hee; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Park, Jung-Hun [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2013-10-15

    Purpose: Little was known about the safety and long-term efficacy of fluoroscopically guided balloon dilation for postintubation tracheal stenosis. The purpose of this study was to evaluate the safety and long-term efficacy of fluoroscopically guided balloon dilation in patients with postintubation tracheal stenosis. Methods: From February 2000 to November 2010, 14 patients underwent fluoroscopically guided balloon dilation for postintubation tracheal stenosis. Technical success, clinical success, and complications were evaluated. Patients were followed up for recurrent symptoms. Results: In all patients, fluoroscopically guided balloon dilation was technically and clinically successful with no major complications. Following the initial procedure, six patients (43 %) remained asymptomatic during a follow-up period. Obstructive symptoms recurred in eight patients (57 %) within 6 months (mean, 1.7 months), who were treated with repeat balloon dilation (n = 4) and other therapies. Of the four patients who underwent repeat balloon dilation, three became asymptomatic. One patient became asymptomatic after a third balloon dilation. On long-term (mean, 74 months) follow-up, 71 % of patients experienced relief of symptoms following fluoroscopically guided balloon dilation. Conclusions: Fluoroscopically guided balloon dilation may be safe, is easy to perform, and resulted in effective treatment in patients with postintubation tracheal stenosis.

  4. Acoustical characterization of exploding hydrogen-oxygen balloons.

    Science.gov (United States)

    Vernon, Julia A; Gee, Kent L; Macedone, Jeffrey H

    2012-03-01

    Exploding hydrogen-oxygen balloons are popular chemistry demonstrations. Although initial research experimentally quantified potential hearing risk via analysis of peak levels [K. L. Gee et al., J. Chem. Educ. 87, 1039-1044 (2010)], further waveform and spectral analyses have been conducted to more fully characterize these impulsive noise sources. While hydrogen-only balloons produce inconsistent reactions and relatively low, variable levels, stoichiometrically mixed hydrogen-oxygen balloons produce consistent high-amplitude noise waveforms. Preliminary consideration is also given to the potential use of these exploding balloons in architectural acoustics applications. PMID:22423815

  5. Hybrid treatment of penetrating aortic ulcer

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Juan Antonio Herrero; Martins-Romeo, Daniela de Araujo; Escudero, Carlos Caparros; Falcon, Maria del Carmen Prieto; Batista, Vinicius Bianchi, E-mail: jaherrero5@hotmail.com [Unidade de Gestao Clinica (UGC) de Diagnostico por Imagem - Hosppital Universitario Virgen Macarena, Sevilha (Spain); Vazquez, Rosa Maria Lepe [Unit of Radiodiagnosis - Hospital Nuestra Senora de la Merced, Osuna, Sevilha (Spain)

    2015-05-15

    Penetrating atherosclerotic aortic ulcer is a rare entity with poor prognosis in the setting of acute aortic syndrome. In the literature, cases like the present one, located in the aortic arch, starting with chest pain and evolving with dysphonia, are even rarer. The present report emphasizes the role played by computed tomography in the diagnosis of penetrating atherosclerotic ulcer as well as in the differentiation of this condition from other acute aortic syndromes. Additionally, the authors describe a new therapeutic approach represented by a hybrid endovascular surgical procedure for treatment of the disease. (author)

  6. Abdominal Aortic Surgery: Anesthetic Implications

    OpenAIRE

    Cunningham, Anthony J.

    1991-01-01

    The objectives of the review are to highlight the clinical characteristics of the patient population; to assess multivariate risk factor analysis and the invasive/non-invasive techniques available for risk factor identification and management in this high-risk surgical population; to assess the major hemodynamic, metabolic, and regional blood flow changes associated with aortic cross-clamping/unclamping procedures and techniques for their modification or attenuation; and to assess the influen...

  7. AUTOPERFUSION BALLOON CATHETER FOR COMPLICATED CORONARY ANGIOPLASTY - A PROSPECTIVE-STUDY WITH RETROSPECTIVE CONTROLS

    NARCIS (Netherlands)

    DEMUINCK, ED; VANDIJK, RB; DENHEIJER, P; MEEDER, JG; LIE, KI

    1992-01-01

    Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with pe

  8. The role of transesophageal echocardiography in aortic surgery.

    Science.gov (United States)

    Nowak-Machen, Martina

    2016-09-01

    Aortic disease, when left untreated, is still associated with major morbidity and mortality. Aortic dissection and aortic aneurysm are the main reasons for performing aortic surgery procedures in the adult. Imaging techniques such as computed tomography and magnetic resonance imaging play a key role in the preoperative evaluation. Transesophageal echocardiography (TEE) has become a safe and invaluable perioperative imaging tool for aortic disease over the past decade with high sensitivity and specificity. TEE can increase patient safety and improve overall patient outcome in aortic surgery. Especially during endovascular aortic repair, TEE is more sensitive than other imaging modalities in diagnosing complications such as graft endoleaks. Newer echocardiographic techniques such as three-dimensional (3D) TEE and contrast-enhanced TEE are emerging and seem to have a valuable role especially in aortic dissection repair and endovascular aortic stent procedures. In the absence of contraindications, TEE should generally be performed during aortic surgery and endovascular aortic procedures. PMID:27650342

  9. Pregnancy after aortic root replacement in Loeys-Dietz syndrome: High risk of aortic dissection.

    Science.gov (United States)

    Braverman, Alan C; Moon, Marc R; Geraghty, Patrick; Willing, Marcia; Bach, Christopher; Kouchoukos, Nicholas T

    2016-08-01

    Loeys-Dietz syndrome due to mutations in TGFBR1 and 2 is associated with early and aggressive aortic aneurysm and branch vessel disease. There are reports of uncomplicated pregnancy in this condition, but there is an increased risk of aortic dissection and uterine rupture. Women with underlying aortic root aneurysm are cautioned about the risk of pregnancy-related aortic dissection. Prophylactic aortic root replacement is recommended in women with aortopathy and aortic root dilatation to lessen the risk of pregnancy. There is limited information in the literature about the outcomes of pregnancy after root replacement in Loeys-Dietz syndrome. We present a case series of three women with Loeys-Dietz syndrome who underwent elective aortic root replacement for aneurysm disease and subsequently became pregnant and underwent Cesarean section delivery. Each of these women were treated with beta blockers throughout pregnancy. Surveillance echocardiograms and noncontrast MRA studies during pregnancy remained stable demonstrating no evidence for aortic enlargement. Despite the normal aortic imaging and careful observation, two of the three women suffered acute aortic dissection in the postpartum period. These cases highlight the high risk of pregnancy following aortic root replacement in Loeys-Dietz syndrome. Women with this disorder are recommended to be counseled accordingly. © 2016 Wiley Periodicals, Inc. PMID:27125181

  10. When and how to replace the aortic root in type A aortic dissection.

    Science.gov (United States)

    Leshnower, Bradley G; Chen, Edward P

    2016-07-01

    Management of aortic root pathology during repair of acute type A aortic dissection (TAAD) requires a comprehensive evaluation of the patient's anatomy, demographics, comorbidities and physiologic status at the time of emergent operative intervention. Surgical options include conservative repair of the root (CRR) (with or without replacement of the aortic valve), replacement of the native valve and aortic root using a composite valve-conduit and valve sparing root replacement (VSRR). The primary objective of this review is to provide data for surgeons to aid in their decision-making process regarding management of the aortic root during repair of TAAD. No time or language restrictions were imposed and references of the selected studies were checked for additional relevant citations. Multiple retrospective reviews have demonstrated equivalent operative mortality between aortic root repair and replacement during TAAD. There is a higher incidence of aortic root reintervention with aortic root repair compared to aortic root replacement (ARR). Experienced, high-volume aortic centers have demonstrated the safety of VSRR in young, hemodynamically stable patients presenting with TAAD. In conclusion, aortic root repair can safely be performed in the vast majority of patients with TAAD. Despite the increased surgical complexity, ARR does not increase operative mortality and improves the freedom from root reintervention. VSRR can be performed in highly selected populations of patients with TAAD with durable mid-term valve function. PMID:27563551

  11. Regional aortic distensibility and its relationship with age and aortic stenosis: a computed tomography study.

    Science.gov (United States)

    Wong, Dennis T L; Narayan, Om; Leong, Darryl P; Bertaso, Angela G; Maia, Murilo G; Ko, Brian S H; Baillie, Timothy; Seneviratne, Sujith K; Worthley, Matthew I; Meredith, Ian T; Cameron, James D

    2015-06-01

    Aortic distensibility (AD) decreases with age and increased aortic stiffness is independently associated with adverse cardiovascular outcomes. The association of severe aortic stenosis (AS) with AD in different aortic regions has not been evaluated. Elderly subjects with severe AS and a cohort of patients without AS of similar age were studied. Proximal aortic cross-sectional-area changes during the cardiac cycle were determined using retrospective-ECG-gating on 128-detector row computed-tomography. Using oscillometric-brachial-blood-pressure measurements, the AD at the ascending-aorta (AA), proximal-descending-aorta (PDA) and distal-descending-aorta (DDA) was determined. Linear mixed effects modelling was used to determine the association of age and aortic stenosis on regional AD. 102 patients were evaluated: 36 AS patients (70-85 years), 24 AS patients (>85 years) and 42 patients without AS (9 patients DDA (1.1 ± 1.2 vs. 1.2 ± 0.8, P = 0.97). In patients without AS, AD decreased with age in all aortic regions (P < 0.001). The AA in patients <50 years were the most distensible compared to other aortic regions. There is regional variation in aortic distensibility with aging. Patients with aortic stenosis demonstrated regional differences in aortic distensibility with lower distensibility demonstrated in the proximal ascending aorta compared to an age-matched cohort. PMID:25855464

  12. Stratospheric composition from balloon based measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mencaraglia, F.; Carli, B. [Ist. per le Ricerche sulle Onde Elettromagnetiche, Firenze (Italy); Bonetti, A.; Ciarpallini, P. [Univ. di Firenze (Italy); Carlotti, M.; Lepri, G. [Univ. di Bologna (Italy); Alboni, F.; Cortesi, U.; Ridolfi, M. [Fondazione per la Metereologia Applicata, Firenze (Italy)

    1995-12-31

    Measurements of the composition of the earth`s atmosphere is of fundamental importance for the study of atmospheric chemistry and for developing models that can predict the evolution of the atmosphere itself. Here, the chemical composition of the lower stratosphere has been measured using a polarizing interferometer operating in the far infrared and submillimetric spectral region. The instrument was flown three times (in 1992, 1993 and 1994) from the NSBF balloon base (Fort Sumner, New Mexico) in coincidence with overpasses of the UARS satellite, for a total of about 50 hours of measurements. In this paper the authors report some of the results obtained from the data analysis made up to now.

  13. Guidelines and Suggestions for Balloon Gondola Design

    Science.gov (United States)

    Franco, Hugo

    2016-01-01

    The Columbia Scientific Balloon Facility is responsible for ensuring that science payloads meet the appropriate design requirements. The ultimate goal is to ensure that payloads stay within the allowable launch limits as well as survive the termination event. The purpose of this presentation is to provide some general guidelines for Gondola Design. These include rules and reasons on why CSBF has a certain preference and location for certain components within the gondola as well as other suggestions. Additionally, some recommendations are given on how to avoid common pitfalls.

  14. General theory of kinetic ballooning modes

    International Nuclear Information System (INIS)

    The ballooning mode formalism, previously developed for the ideal MHD problem, is applied here to the kinetic problem in tokamaks. The general two-dimensional equation governing drift and trapped-electron eigenmodes reduces to a one-dimensional integral equation along the lines of force with the radial structure determined by a WKB procedure. Comparisons made between the present one-dimensional code and a previous two-dimensional code embodying identical physical assumptions indicate reasonable agreement. This correspondence holds both for the structure along the field line and for the radial structure in the special case of closely spaced turning points

  15. Pneumothorax, music and balloons: A case series

    Directory of Open Access Journals (Sweden)

    Shiferaw Dejene

    2013-01-01

    Full Text Available We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation.

  16. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? PMID:27543477

  17. Ballooning Spiders: The Case for Electrostatic Flight

    CERN Document Server

    Gorham, Peter W

    2013-01-01

    We consider general aspects of the physics underlying the flight of Gossamer spiders, also known as ballooning spiders. We show that existing observations and the physics of spider silk in the presence of the Earth's static atmospheric electric field indicate a potentially important role for electrostatic forces in the flight of Gossamer spiders. A compelling example is analyzed in detail, motivated by the observed "unaccountable rapidity" in the launching of such spiders from H.M.S. Beagle, recorded by Charles Darwin during his famous voyage.

  18. Double-balloon endoscopy: Who needs it?

    DEFF Research Database (Denmark)

    Hendel, J.W.; Vilmann, P.; Jensen, T.

    2008-01-01

    Objective. Double-balloon endoscopy (DBE) made the small bowel accessible to inspection and therapy in its entirety. However, DBE is a time-consuming procedure that requires a highly skilled endoscopist, several nurses and - more often than not - anesthesiological support. This makes the selection...... of patients for DBE a pivotal point. The mainstay of this screening examination of the small bowel is capsule endoscopy (CE). The aim of this study was to describe the results of this screening procedure and the subsequent DBE in patients with suspected mid-gastrointestinal bleeding (MGIB). Material...

  19. Pneumothorax, music and balloons: A case series.

    Science.gov (United States)

    Dejene, Shiferaw; Ahmed, Fahim; Jack, Kastelik; Anthony, Arnorld

    2013-07-01

    We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation. PMID:23922614

  20. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  1. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  2. Open conversion after endovascular aortic aneurysm repair with the Ovation Prime™ endograft.

    Science.gov (United States)

    Georgiadis, George S; Charalampidis, Dimitrios; Georgakarakos, Efstratios I; Antoniou, George A; Trellopoulos, George; Vogiatzaki, Theodosia; Lazarides, Miltos K

    2014-02-01

    Advances in abdominal aortic aneurysm (AAA) endograft device technology have contributed to improved outcomes and durability of endovascular aortic aneurysm repair (EVAR), even in complex infrarenal aortic anatomies. However, stent graft failure secondary to endoleaks, migration, endotension and sac enlargement are persistent problems that can result in aneurysm rupture following EVAR.A symptomatic infrarenal AAA (4mm proximal neck) was treated initially with an Ovation Prime™ device (TriVascular, Inc., Santa Rosa, CA) in an off-label fashion, leading to type Ia endoleak moderately reduced by additional proximal neck ballooning. A failed Chimney technique to the single patent, but severely stenosed, right renal artery preceded the use of this device. A large type Ia endoleak was evident at 6-month follow-up, but following a failed supplementary endovascular intervention with coils to seal the endoleak, the patient presented with hemorrhagic shock from AAA rupture, requiring urgent open conversion. Intraoperatively it was impossible to explant this new type of endograft. Circumferential tying of the infrarenal aorta with a Teflon band was unable to stop the bleeding. However, after dividing the body of the stent-graft below the two proximal polymer rings, the endoleak was successfully treated by suturing the graft with the proximal aortic neck. The procedure was completed with extension of the stump to the common femoral arteries using a bifurcated Dacron prosthesis.The body of an Ovation Prime™ endograft may be impossible to explant in open conversion conditions. Large prospective studies with longer follow-up are required to adequately reflect the behavior of this particular device. PMID:24619891

  3. Feasibility of Pump Speed Modulation for Restoring Vascular Pulsatility with Rotary Blood Pumps.

    Science.gov (United States)

    Ising, Mickey S; Sobieski, Michael A; Slaughter, Mark S; Koenig, Steven C; Giridharan, Guruprasad A

    2015-01-01

    Continuous flow (CF) left ventricular assist devices (LVAD) diminish vascular pressure pulsatility, which may be associated with clinically reported adverse events including gastrointestinal bleeding, aortic valve insufficiency, and hemorrhagic stroke. Three candidate CF LVAD pump speed modulation algorithms designed to augment aortic pulsatility were evaluated in mock flow loop and ischemic heart failure (IHF) bovine models by quantifying hemodynamic performance as a function of mean pump speed, modulation amplitude, and timing. Asynchronous and synchronous copulsation (high revolutions per minute [RPM] during systole, low RPM during diastole) and counterpulsation (low RPM during systole, high RPM during diastole) algorithms were tested for defined modulation amplitudes (±300, ±500, ±800, and ±1,100 RPM) and frequencies (18.75, 37.5, and 60 cycles/minute) at low (2,900 RPM) and high (3,200 RPM) mean LVAD speeds. In the mock flow loop model, asynchronous, synchronous copulsation, and synchronous counterpulsation algorithms each increased pulse pressure (ΔP = 931%, 210%, and 98% and reduced left ventricular external work (LVEW = 20%, 22%, 16%). Similar improvements in vascular pulsatility (1,142%) and LVEW (40%) were observed in the IHF bovine model. Asynchronous modulation produces the largest vascular pulsatility with the advantage of not requiring sensor(s) for timing pump speed modulation, facilitating potential clinical implementation. PMID:26102173

  4. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surg

  5. Thoraco-abdominal aortic aneurysm branched repair

    NARCIS (Netherlands)

    Verhoeven, E. L. G.; Tielliu, I. F. J.; Ferreira, M.; Zipfel, B.; Adam, D. J.

    2010-01-01

    Open thoraco-abdominal aortic aneurysm repair is a demanding procedure with high impact on the patient and the operating team. Results from expert centres show mortality rates between 3-21%, with extensive morbidity including renal failure and paraplegia. Endovascular repair of abdominal aortic aneu

  6. Magnetic Resonance Imaging of Thoracic Aortic Dissections

    OpenAIRE

    Sax, Steven L.

    1990-01-01

    Magnetic resonance imaging is an excellent noninvasive method for evaluating thoracic aortic dissections. A variety of magnetic resonance scans of aortic dissections are shown, documenting the ability of magnetic resonance to image the true lumen, the false channel, and the intimal septum. Detail is provided on magnetic resonance imaging techniques and findings. (Texas Heart Institute Journal 1990;17:262-70)

  7. Transcatheter Aortic Valve Replacement in Europe

    DEFF Research Database (Denmark)

    Mylotte, Darren; Osnabrugge, Ruben L J; Windecker, Stephan;

    2013-01-01

    The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy.......The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy....

  8. Global Strain in Severe Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbæk, Lars; Poulsen, Mikael K;

    2012-01-01

    BACKGROUND: -Global longitudinal systolic strain (GLS) is often reduced in aortic stenosis despite normal ejection fraction. The importance of reduced preoperative GLS on long-term outcome after aortic valve replacement (AVR) is unknown. METHODS AND RESULTS: -A total of 125 patients with severe...

  9. Reversible transient apical ballooning syndrome with coronary lesions

    Institute of Scientific and Technical Information of China (English)

    Yunshan Cao; Min Zhang; Xiang Li; Ping Xie; Lynn Cronin

    2009-01-01

    Transient apical ballooning syndrome(Tako-Tsubo syndrome or ampulla cardiomyopathy) occurs predominantly in women over 60 years of age with a history of recent physical or psychological stress. We present a case of a male patient with reversible transient apical ballooning syndrome with significant coronary lesions and other ECG changes that did not explain the clinical symptoms.

  10. 21 CFR 870.1350 - Catheter balloon repair kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the... effect the repair or replacement. (b) Classification. Class III (premarket approval). (c) Date PMA...

  11. Recent developments in the scientific ballooning in India

    Science.gov (United States)

    Manchanda, R.; Sreenivasan, S.; Subbarao, J.; Kumar, P.

    RECENT DEVELOPMENTS IN THE SCIENTIFIC BALLOONING IN INDIA R. K. Manchanda1, S. Sreenivasan2, J. V. Subbarao2, P. R. Kumar2 1. Tata Institute of Fundamental Research Colaba, Mumbai-400 005, India. 2. TIFR Balloon Facility, PO Box 5, ECIL Post Office, Hyderabad-500 762, India ravi@tifr.res.in/FAX: +91-22-2152110 National Balloon facility operated by TIFR in Hyderabad, India is the only one of its kind in the world, which combines both, the in-house balloon production and a complete flight support for scientific ballooning. In the past few years we executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years and the results of the test flight conducted to qualify new sub systems will be presented.

  12. EUSO-Balloon: The first flight

    Science.gov (United States)

    Scotti, Valentina; Osteria, Giuseppe

    2016-07-01

    EUSO-Balloon is a pathfinder mission for JEM-EUSO, the near-UV telescope proposed to be installed on board the International Space Station (ISS). The main objective of this pathfinder mission is to perform a full scale end-to-end test of all the key technologies of JEM-EUSO detectors and to measure the UV background. The JEM-EUSO instrument consists of UV telescope designed to focus the signal of the UV tracks generated by Extreme Energy Cosmic Rays propagating in Earth's atmosphere, onto a finely pixelized UV camera. The EUSO-Balloon instrument, smaller than the one designed for the ISS, was launched on August 2014 from Timmins (Ontario, Canada). The flight lasted about five hours and the instrument reached a float altitude of about 40 km. From this altitude the telescope registered, at a rate of 400 000 frames/s, the nightglow background on forests, lakes and clouds, as well as city lights and artificial air showers tracks generated by means of a laser installed on an helicopter flying inside its field of view. In this contribution we will describe the instrument and its performance during the first flight.

  13. Spectrum of the ballooning Schroedinger equation

    International Nuclear Information System (INIS)

    The ballooning Schroedinger equation (BSE) is a model equation for investigating global modes that can, when approximated by a Wentzel-Kramers-Brillouin (WKB) ansatz, be described by a ballooning formalism locally to a field line. This second order differential equation with coefficients periodic in the independent variable θk is assumed to apply even in cases where simple WKB quantization conditions break down, thus providing an alternative to semiclassical quantization. Also, it provides a test bed for developing more advanced WKB methods: e.g. the apparent discontinuity between quantization formulae for open-quotes trappedclose quotes and open-quotes passingclose quotes modes, whose ray paths have different topologies, is removed by extending the WKB method to include the phenomena of tunnelling and reflection. The BSE is applied to instabilities with shear in the real part of the local frequency, so that the dispersion relation is inherently complex. As the frequency shear is increased, it is found that trapped modes go over to passing modes, reducing the maximum growth rate by averaging over θk

  14. Intravascular ultrasound imaging following balloon angioplasty.

    Science.gov (United States)

    Tobis, J M; Mahon, D J; Moriuchi, M; Honye, J; McRae, M

    1991-01-01

    Despite its long history and reliability, contrast angiography has several inherent limitations. Because it is a two-dimensional projection image of the lumen contour, the wall thickness cannot be measured and the plaque itself is not visualized. This results in an underestimation of the amount of atherosclerotic disease by angiography. An assessment of atherosclerosis could be improved by an imaging modality: (1) that has an inherent larger magnification than angiography and (2) that directly visualizes the plaque. Intravascular ultrasound fulfils these criteria. This presentation will provide evidence that intravascular ultrasound may prove complimentary or even superior to angiography as an imaging modality. Intravascular ultrasound demonstrates excellent representations of lumen and plaque morphology of in vitro specimens compared with histology. There is very close intraobserver and interobserver variability of measurements made from intravascular ultrasound images. Phantom studies of stenoses in a tube model demonstrate that angiography can misrepresent the severity of stenosis when the lumen contour is irregular and not a typical ellipse, whereas intravascular ultrasound reproduces the cross-sectional morphology more accurately since it images the artery from within. In vitro studies of the atherosclerotic plaque tissue characteristics compare closely with the echo representation of fibrosis, calcification, and lipid material. In addition, in vitro studies of balloon angioplasty demonstrate that intravascular ultrasound accurately represents the changes in the structure of artery segments following balloon dilatation. PMID:1833473

  15. Acute aortic dissection in pregnant women.

    Science.gov (United States)

    Yang, Zhaohua; Yang, Shouguo; Wang, Fangshun; Wang, Chunsheng

    2016-05-01

    Acute aortic dissection occurring during pregnancy represents a lethal risk to both the mother and fetus. Management of parturient with acute aortic dissection is complex. We report our experience of two pregnancies with type A acute aortic dissection. One patient is a 31-year-old pregnant woman (33rd gestational week) with a bicuspid aortic valve and the other is a 32-year-old pregnant woman (30th gestational week) with the Marfan syndrome. In both cases, a combined emergency operation consisting of Cesarean section, total hysterectomy prior to corrective surgery for aortic dissection was successfully performed within a relatively short period of time after the onset. Both patients' postoperative recovery was uneventful, and we achieved a favorable maternal and fetal outcome. PMID:25085319

  16. Organ protection during aortic cross-clamping.

    Science.gov (United States)

    Yeung, Kak Khee; Groeneveld, Menno; Lu, Joyce Ja-Ning; van Diemen, Pepijn; Jongkind, Vincent; Wisselink, Willem

    2016-09-01

    Open surgical repair of an aortic aneurysm requires aortic cross-clamping, resulting in temporary ischemia of all organs and tissues supplied by the aorta distal to the clamp. Major complications of open aneurysm repair due to aortic cross-clamping include renal ischemia-reperfusion injury and postoperative colonic ischemia in case of supra- and infrarenal aortic aneurysm repair. Ischemia-reperfusion injury results in excessive production of reactive oxygen species and in oxidative stress, which can lead to multiple organ failure. Several perioperative protective strategies have been suggested to preserve renal function during aortic cross-clamping, such as pharmacotherapy and therapeutic hypothermia of the kidneys. In this chapter, we will briefly discuss the pathophysiology of ischemia-reperfusion injury and the preventative measures that can be taken to avoid abdominal organ injury. Finally, techniques to minimize the risk of complications during and after open aneurysm repair will be presented. PMID:27650341

  17. Intraoperative tracking of aortic valve plane

    Science.gov (United States)

    Nguyen, Duc Long Hung; Garreau, Mireille; Auffret, Vincent; Le Breton, Hervé; Verhoye, Jean-Philippe; Haigron, Pascal

    2013-01-01

    The main objective of this work is to track the aortic valve plane in intra-operative fluoroscopic images in order to optimize and secure Transcatheter Aortic Valve Implantation (TAVI) procedure. This paper is focused on the issue of aortic valve calcifications tracking in fluoroscopic images. We propose a new method based on the Tracking-Learning-Detection approach, applied to the aortic valve calcifications in order to determine the position of the aortic valve plane in intra-operative TAVI images. This main contribution concerns the improvement of object detection by updating the recursive tracker in which all features are tracked jointly. The approach has been evaluated on four patient databases, providing an absolute mean displacement error less than 10 pixels ≈ 2mm). Its suitability for the TAVI procedure has been analyzed. PMID:24110703

  18. Stroke in Patients With Aortic Stenosis

    DEFF Research Database (Denmark)

    Greve, Anders Møller; Dalsgaard, Morten; Bang, Casper N;

    2014-01-01

    , and poststroke survival a secondary outcome. Cox models treating AVR as a time-varying covariate were adjusted for atrial fibrillation and congestive heart failure, hypertension, age≥75 years, diabetes mellitus, stroke/transient ischemic attack, vascular disease, age 65-74 years and female sex (CHA2DS2-VASc......BACKGROUND AND PURPOSE: There are limited data on risk stratification of stroke in aortic stenosis. This study examined predictors of stroke in aortic stenosis, the prognostic implications of stroke, and how aortic valve replacement (AVR) with or without concomitant coronary artery bypass grafting...... influenced the predicted outcomes. METHODS: Patients with mild-to-moderate aortic stenosis enrolled in the Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study. Diabetes mellitus, known atherosclerotic disease, and oral anticoagulation were exclusion criteria. Ischemic stroke was the primary end point...

  19. Transcatheter aortic valve replacement in elderly patients

    Institute of Scientific and Technical Information of China (English)

    Dimytri Siqueira; Alexandre Abizaid; Magaly Arrais J.; Eduardo Sousa

    2012-01-01

    Aortic stenosis is the most common native valve disease, affecting up to 5% of the elderly population. Surgical aortic valve replacement reduces symptoms and improves survival, and is the definitive therapy in patients with symptomatic severe aortic stenosis. However, despite the good results of classic surgery, risk is markedly increased in elderly patients with co-morbidities. Transcatheter aortic valve replacement (TAVR) allows implantation of a prosthetic heart valve within the diseased native aortic valve without the need for open heart surgery and cardiopulmonary bypass, offering a new therapeutic option to elderly patients considered at high surgical risk or with contraindications to surgery. To date, several multicenter registries and a randomized trial have confirmed the safety and efficacy of TAVR in those patients. In this chapter, we review the background and clinical applications of TAVR in elderly patients.

  20. Balloon concepts for scientific investigation of Mars and Jupiter

    Science.gov (United States)

    Ash, R. L.

    1979-01-01

    Opportunities for scientific investigation of the atmospheric planets using buoyant balloons have been explored. Mars and Jupiter were considered in this study because design requirements at those planets bracket nominally the requirements at Venus, and plans are already underway for a joint Russian-French balloon system at Venus. Viking data has provided quantitative information for definition of specific balloon systems at Mars. Free flying balloons appear capable of providing valuable scientific support for more sophisticated Martian surface probes, but tethered and powered aerostats are not attractive. The Jovian environment is so extreme, hot atmosphere balloons may be the only scientific platforms capable of extended operations there. However, the estimated system mass and thermal energy required are very large.

  1. An overview of instrumentation capabilities for Scientific ballooning in India

    Science.gov (United States)

    Devarajan, Anand; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Bangaru, Kapardhi; Trivedi, Dharmesh; Rodi, Ashish; Ojha, Devendra; Koli, Santosh

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) in India, launches scientific balloons for research in the field of astronomy, astrobiology and atmospheric sciences. TIFR-BF not only has the capability to design, fabricate and launch zero-pressure balloons, but also provide operational and engineering support for launching them. The Control Instrumentation Group (CIG) at the balloon facility handles all electronics related to telemetry, telecommand, tracking, real-time data display, data storage, air-safety and payload recovery. In the recent past, it has designed and developed customized electronics and payload orientation mechanism to meet specific experimental objectives. Small, inexpensive and rugged industrial grade radio data modems were successfully deployed in balloon flights for low bit rate data and image telemetry. This paper will provide an overview and in-flight performance of some of the recent developments in instrumentation and electronics systems. Our plans for future upgradations will also be discussed.

  2. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  3. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  4. A New Paradigm in Space Based Experiments Using Rubber Balloons

    CERN Document Server

    Chakrabarti, Sandip K; Palit, Sourav; Chakraborty, Subhankar; Mondal, Sushanta; Bhattacharyya, Arnab; Middya, Susanta; Chakrabarti, Sonali

    2013-01-01

    Indian Centre for Space Physics is engaged in long duration balloon borne experiments with typical payloads less than ~ 3kg. Low cost rubber balloons are used. In a double balloon system, the booster balloon lifts the orbiter balloon to its cruising altitude where data is taken for a long time. Here we present results of muon detections and recent solar activities, including the light curves and flare spectra in the 20-100keV range. We not only show that we have successfully obtained several flares and there spectra at different altitudes, we also found that the high energy X-ray flux of strong flares at altitudes of 10-13 km (the flight altitude of commercial planes) could be more than the contribution due to cosmic rays.

  5. Aorta Balloon Occlusion in Trauma: Three Cases Demonstrating Multidisciplinary Approach Already on Patient’s Arrival to the Emergency Room

    Energy Technology Data Exchange (ETDEWEB)

    Hörer, Tal M., E-mail: tal.horer@orebroll.se [Örebro University, Department of Cardiothoracic and Vascular Surgery, Örebro University Hospital (Sweden); Hebron, Dan [Hillel Yaffe Medical Center, Department of Radiology (Israel); Swaid, Forat [Bnai-Zion Medical Center, Department of General Surgery (Israel); Korin, Alexander [Hillel Yaffe Medical Center, Trauma Unit (Israel); Galili, Offer [Hillel Yaffe Medical Center, Department of Vascular Surgery (Israel); Alfici, Ricardo [Hillel Yaffe Medical Center, Surgical Division (Israel); Kessel, Boris [Hillel Yaffe Medical Center, Trauma Unit (Israel)

    2016-02-15

    PurposeTo describe the usage of aortic balloon occlusion (ABO), based on a multidisciplinary approach in severe trauma patients, emphasizing the role of the interventional radiologist in primary trauma care.MethodsWe briefly discuss the relevant literature, the technical aspects of ABO in trauma, and a multidisciplinary approach to the bleeding trauma patient. We describe three severely injured trauma patients for whom ABO was part of initial trauma management.ResultsThree severely injured multi-trauma patients were treated by ABO as a bridge to surgery and embolization. The procedures were performed by an interventional radiologist in the early stages of trauma management.ConclusionsThe interventional radiologist and the multidisciplinary team approach can be activated already on severe trauma patient arrival. ABO usage and other endovascular methods are becoming more widely spread, and can be used early in trauma management, without delay, thus justifying the early activation of this multidisciplinary approach.

  6. Prevalence of De Novo Aortic Valve Insufficiency in Patients After HeartWare VAD Implantation with an Intermittent Low-Speed Algorithm.

    Science.gov (United States)

    Saeed, Diyar; Westenfeld, Ralf; Maxhera, Bujar; Keymel, Stefanie; Sherif, Ahmed; Sadat, Najla; Petrov, GeorGI; Albert, Alexander; Lichtenberg, Artur

    2016-01-01

    De novo aortic valve insufficiency (AI) is a frequent occurrence in patients supported with left ventricular assist device (LVAD). The European version of the HeartWare LVAD has intermittent low-speed software (lavare cycle) to facilitate intermittent aortic valve opening. We examined aortic valve opening status and prevalence of AI in patients supported with HeartWare LVAD and activated lavare cycle. HeartWare LVAD patients were prospectively monitored using serial echocardiograms at different time points after the LVAD implantation. Inclusion criteria were patients with no > mild AI and/or no aortic valve surgery at the time of LVAD implantation and at least 60 days of support. Three of 37 patients had aortic valve surgery and were excluded from the analysis. A total of 34 patients with mean age of 57 ± 12 years met the inclusion criteria. After median support duration of 408 days (77-1250 days), eight patients had trace/mild AI (24%) and one patient developed moderate AI (3%). An average pump flow, speed, and mean arterial pressure of 4.4 ± 0.6 L/min, 2,585 ± 147 rpm, and 88 ± 11 mmHg were documented, respectively. Aortic valve opening was persistently seen in 22 patients (65%). Aortic valve opening is frequent, and the development of > mild AI seems to be rare in patients supported with HeartWare LVAD. PMID:27195744

  7. Comparative in Vitro Research of the Human Aortic Bioprosthesis

    Directory of Open Access Journals (Sweden)

    Dawidowska K.

    2014-12-01

    Full Text Available Evaluate of the usefulness and reliability of structures based on the analysis of recorded parameters determining the flow through the Human Aortic Bioprosthesis (HAB have been dealt with. By flow parameters changes determining the performance environment of prosthesis analyzed change of the motion dynamics of the valve leaflets as a function of pressure, thereby determining the degree of alignment of the prosthesis to the performance conditions. Based on the gathered measurement data a comparative analysis of flow rate valve prostheses for different frequency values of the piston pump imitating the heart, different ejection capacity and pressure conditioning work environment prosthesis were studied. Interpretation of the recorded image gave the basis for determining the Effective Orifice Area (EOC.

  8. Reoperation on aortic disease in patients with previous aortic valve surgery

    Institute of Scientific and Technical Information of China (English)

    SUN Xiao-gang; ZHANG Liang; YU Cun-tao; QIAN Xiang-yang; CHANG Qian

    2013-01-01

    Background Aortic valve replacement (AVR) is a safe and effective method in the treatment of aortic valve diseases.This study aimed to increase the understanding on re-treatment of aortic diseases after aortic valve surgery through a retrospective analysis of 47 related cases.Methods Forty-seven patients (38 males and 9 females) with previous aortic valve surgery have received reoperation on aorta from January 2003 to June 2012,and the mean interval time of re-intervention to aortic disease was 6 years ((6.0± 3.8) years).The secondary aortic surgery included aortic root replacement (14 cases),ascending aorta replacement (10 cases),aortic root/ascending aorta plus total arch replacement with stented elephant trunk implantation (21 cases),and total thoracoabdominal aorta replacement (2 cases).All these patients have received outpatient re-exams or follow-up by phone calls.Results After the initial aortic valve replacement,patients suffered from aortic dissection (25 cases,53%),ascending aortic aneurysm (12 cases,26%) or aortic root aneurysm (10 cases,21%).Diameter in ascending aorta increased (5.2±7.1) mm per year and aortic sinus (3.3±3.1) mm per year.The annual growth value of diameter in ascending aorta was higher in patients with rheumatic heart disease than that in Marfan syndrome (P<0.05).All 47 patients have received reoperation on aorta.One patient died in operating room because aortic dissection seriously involved right coronary artery.Seven patients had renal insufficiency after operation; neurological complications occurred in 14 patients including 7 patients with stroke and the others with transient brain dysfunction.All patients were followed up,the mean survival time was (97.25±17.63) months,95% confidence interval was 55.24-73.33 months.Eight cases were died during follow-up and five-year survival rate was 83%.Conclusion To reduce the aortic adverse events after first aortic valve surgery,it is necessary to actively treat and strictly

  9. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    1991-01-01

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  10. Dynamic heart phantom with functional mitral and aortic valves

    Science.gov (United States)

    Vannelli, Claire; Moore, John; McLeod, Jonathan; Ceh, Dennis; Peters, Terry

    2015-03-01

    Cardiac valvular stenosis, prolapse and regurgitation are increasingly common conditions, particularly in an elderly population with limited potential for on-pump cardiac surgery. NeoChord©, MitraClipand numerous stent-based transcatheter aortic valve implantation (TAVI) devices provide an alternative to intrusive cardiac operations; performed while the heart is beating, these procedures require surgeons and cardiologists to learn new image-guidance based techniques. Developing these visual aids and protocols is a challenging task that benefits from sophisticated simulators. Existing models lack features needed to simulate off-pump valvular procedures: functional, dynamic valves, apical and vascular access, and user flexibility for different activation patterns such as variable heart rates and rapid pacing. We present a left ventricle phantom with these characteristics. The phantom can be used to simulate valvular repair and replacement procedures with magnetic tracking, augmented reality, fluoroscopy and ultrasound guidance. This tool serves as a platform to develop image-guidance and image processing techniques required for a range of minimally invasive cardiac interventions. The phantom mimics in vivo mitral and aortic valve motion, permitting realistic ultrasound images of these components to be acquired. It also has a physiological realistic left ventricular ejection fraction of 50%. Given its realistic imaging properties and non-biodegradable composition—silicone for tissue, water for blood—the system promises to reduce the number of animal trials required to develop image guidance applications for valvular repair and replacement. The phantom has been used in validation studies for both TAVI image-guidance techniques1, and image-based mitral valve tracking algorithms2.

  11. Screening for Abdominal Aortic Aneurysm

    OpenAIRE

    Linné, Anneli

    2014-01-01

    Abdominal Aortic Aneurysm (AAA) is a common disease with a prevalence of 1.5-2.0% in 65-year old men in Sweden. The risk of having AAA is increased with smoking, high age, family history of AAA and cardiovascular disease. Women have a lower prevalence (0.5%) and develop AAA later in life. An AAA seldom gives any symptom prior to rupture. Untreated rupture is associated with 100% mortality, while surgically treated rupture is associated with 25-70% mortality. Prophylactic sur...

  12. Aortic valve and ascending aortic root modeling from 3D and 3D+t CT

    Science.gov (United States)

    Grbic, Saša; Ionasec, Razvan I.; Zäuner, Dominik; Zheng, Yefeng; Georgescu, Bogdan; Comaniciu, Dorin

    2010-02-01

    Aortic valve disorders are the most frequent form of valvular heart disorders (VHD) affecting nearly 3% of the global population. A large fraction among them are aortic root diseases, such as aortic root aneurysm, often requiring surgical procedures (valve-sparing) as a treatment. Visual non-invasive assessment techniques could assist during pre-selection of adequate patients, planning procedures and afterward evaluation of the same. However state of the art approaches try to model a rather short part of the aortic root, insufficient to assist the physician during intervention planning. In this paper we propose a novel approach for morphological and functional quantification of both the aortic valve and the ascending aortic root. A novel physiological shape model is introduced, consisting of the aortic valve root, leaflets and the ascending aortic root. The model parameters are hierarchically estimated using robust and fast learning-based methods. Experiments performed on 63 CT sequences (630 Volumes) and 20 single phase CT volumes demonstrated an accuracy of 1.45mm and an performance of 30 seconds (3D+t) for this approach. To the best of our knowledge this is the first time a complete model of the aortic valve (including leaflets) and the ascending aortic root, estimated from CT, has been proposed.

  13. Bicuspid Aortic Valve Disease and Ascending Aortic Aneurysms: Gaps in Knowledge

    Directory of Open Access Journals (Sweden)

    Katie L. Losenno

    2012-01-01

    Full Text Available The bicuspid aortic valve is the most common congenital cardiac anomaly in developed nations. The abnormal bicuspid morphology of the aortic valve results in valvular dysfunction and subsequent hemodynamic derangements. However, the clinical presentation of bicuspid aortic valve disease remains quite heterogeneous with patients presenting from infancy to late adulthood with variable degrees of valvular stenosis and insufficiency and associated abnormalities including aortic coarctation, hypoplastic left heart structures, and ascending aortic dilatation. Emerging evidence suggests that the heterogeneous presentation of bicuspid aortic valve phenotypes may be a more complex matter related to congenital, genetic, and/or connective tissue abnormalities. Optimal management of patients with BAV disease and associated ascending aortic aneurysms often requires a thoughtful approach, carefully assessing various risk factors of the aortic valve and the aorta and discerning individual indications for ongoing surveillance, medical management, and operative intervention. We review current concepts of anatomic classification, pathophysiology, natural history, and clinical management of bicuspid aortic valve disease with associated ascending aortic aneurysms.

  14. Aortic root size and prevalence of aortic regurgitation in elite strength trained athletes.

    Science.gov (United States)

    Babaee Bigi, Mohammad Ali; Aslani, Amir

    2007-08-01

    Athletes involved in mainly static or isometric exercise (e.g., weight lifting, power lifting, and bodybuilding) develop pressure overloads due to the high systemic arterial pressure found in this type of exercise. It is hypothesized that chronically elevated aortic wall tension in strength-trained athletes is associated with aortic dilatation and regurgitation. The aim of this study was to evaluate aortic root size and the prevalence of aortic regurgitation in elite strength-trained athletes. The cohort included 100 male athletes (mean age 22.1 +/- 3.6 years; all were finalists or medalists in the country) and 128 healthy age- and height-matched subjects (the control group). Aortic root diameters at end-diastole were measured at 4 locations: (1) the aortic annulus, (2) the sinuses of Valsalva, (3) the sinotubular junction, and (4) the maximal diameter of the proximal ascending aorta. Aortic root diameters at all levels were significantly greater in the strength-trained athletes (p 18 and 36 and 54 months), progressive enlargement was found at all aortic diameters. In conclusion, aortic root diameters in all segments of the aortic root were significantly greater in elite strength-trained athletes compared with an age- and height-matched population.

  15. Giant Thoracic Aneurysm Following Valve Replacement for Bicuspid Aortic Valve.

    Science.gov (United States)

    Tran, Cao; Ul Haq, Ehtesham; Nguyen, Ngoc; Omar, Bassam

    2015-01-01

    Bicuspid aortic valve is a common congenital anomaly associated with aortopathy, which can cause aortic root dilatation, necessitating regular screening if the aortic root is > 4.0 cm. Despite the low absolute incidence of aortic complications associated with bicuspid aortic valve in the general population, the consequences of such complications for an individual patient can be devastating. Herein we propose a balanced algorithm that incorporates recommendations from the three major guidelines for follow-up imaging of the aortic root and ascending thoracic aorta in patients with a bicuspid aortic valve, maintaining the current recommendations with regard to surgical thresholds. PMID:26827748

  16. LMFBR with booster pump in pumping loop

    Science.gov (United States)

    Rubinstein, H.J.

    1975-10-14

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation.

  17. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  18. In vitro validation of flow measurements in an aortic nitinol stent graft by velocity-encoded MRI

    Energy Technology Data Exchange (ETDEWEB)

    Rengier, Fabian, E-mail: f.rengier@dkfz.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); German Cancer Research Center (dkfz) Heidelberg, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Delles, Michael, E-mail: delles@kit.edu [Karlsruhe Institute of Technology (KIT), Department of Informatics, Institute for Anthropomatics, Adenauerring 2, 76131 Karlsruhe (Germany); Weber, Tim Frederik, E-mail: Tim.Weber@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Boeckler, Dittmar, E-mail: dboeckler@me.com [University Hospital Heidelberg, Department of Vascular and Endovascular Surgery, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Ley, Sebastian, E-mail: ley@gmx.net [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich, E-mail: Hans-Ulrich.Kauczor@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Tengg-Kobligk, Hendrik von, E-mail: h.vontengg@dkfz.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); German Cancer Research Center (dkfz) Heidelberg, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)

    2011-10-15

    Purpose: To validate flow measurements within an aortic nickel-titanium (nitinol) stent graft using velocity-encoded cine magnetic resonance imaging (VEC MRI) and to assess intraobserver agreement of repeated flow measurements. Materials and methods: An elastic tube phantom mimicking the descending aorta was developed with the possibility to insert an aortic nitinol stent graft. Different flow patterns (constant, sinusoidal and pulsatile aortic flow) were applied by a gear pump. A two-dimensional phase-contrast sequence was used to acquire VEC perpendicular cross-sections at six equidistant levels along the phantom. Each acquisition was performed twice with and without stent graft, and each dataset was analysed twice by the same reader. The percental difference of the measured flow volume to the gold standard (pump setting) was defined as the parameter for accuracy. Furthermore, the intraobserver agreement was assessed. Results: Mean accuracy of flow volume measurements was -0.45 {+-} 1.63% without stent graft and -0.18 {+-} 1.45% with stent graft. Slightly lower accuracy was obtained for aortic flow both without (-2.31%) and with (-1.29%) stent graft. Accuracy was neither influenced by the measurement position nor by repeated acquisitions. There was significant intraobserver agreement with an intraclass correlation coefficient of 0.87 (without stent graft, p < 0.001) and 0.80 (with stent graft, p < 0.001). The coefficient of variance was 0.25% without stent graft and 0.28% with stent graft. Conclusion: This study demonstrated high accuracy and excellent intraobserver agreement of flow measurements within an aortic nitinol stent graft using VEC MRI. VEC MRI may give new insights into the haemodynamic consequences of endovascular aortic repair.

  19. Microgravity combustion experiment using high altitude balloon.

    Science.gov (United States)

    Kan, Yuji

    In JAXA, microgravity experiment system using a high altitude balloon was developed , for good microgravity environment and short turn-around time. In this publication, I give an account of themicrogravity experiment system and a combustion experiment to utilize the system. The balloon operated vehicle (BOV) as a microgravity experiment system was developed from 2004 to 2009. Features of the BOV are (1) BOV has double capsule structure. Outside-capsule and inside-capsule are kept the non-contact state by 3-axis drag-free control. (2) The payload is spherical shape and itsdiameter is about 300 mm. (3) Keep 10-4 G level microgravity environment for about 30 seconds However, BOV’s payload was small, and could not mount large experiment module. In this study, inherits the results of past, we established a new experimental system called “iBOV” in order toaccommodate larger payload. Features of the iBOV are (1) Drag-free control use for only vertical direction. (2) The payload is a cylindrical shape and its size is about 300 mm in diameter and 700 mm in height. (3) Keep 10-3-10-4 G level microgravity environment for about 30 seconds We have "Observation experiment of flame propagation behavior of the droplets column" as experiment using iBOV. This experiment is a theme that was selected first for technical demonstration of iBOV. We are conducting the flame propagation mechanism elucidation study of fuel droplets array was placed at regular intervals. We conducted a microgravity experiments using TEXUS rocket ESA and drop tower. For this microgravity combustion experiment using high altitude balloon, we use the Engineering Model (EM) for TEXUS rocket experiment. The EM (This payload) consists of combustion vessel, droplets supporter, droplets generator, fuel syringe, igniter, digital camera, high-speed camera. And, This payload was improved from the EM as follows. (1) Add a control unit. (2) Add inside batteries for control unit and heater of combustion

  20. Microcontroller uses in Long-Duration Ballooning

    Science.gov (United States)

    Jones, Joseph

    This paper discusses how microcontrollers are being utilized to fulfill the demands of long duration ballooning (LDB) and the advantages of doing so. The Columbia Scientific Balloon Facility (CSBF) offers the service of launching high altitude balloons (120k ft) which provide an over the horizon telemetry system and platform for scientific research payloads to collect data. CSBF has utilized microcontrollers to address multiple tasks and functions which were previously performed by more complex systems. A microcontroller system has been recently developed and programmed in house to replace our previous backup navigation system which is used on all LDB flights. A similar microcontroller system was developed to be independently launched in Antarctica before the actual scientific payload. This system's function is to transmit its GPS position and a small housekeeping packet so that we can confirm the upper level float winds are as predicted from satellite derived models. Microcontrollers have also been used to create test equipment to functionally check out the flight hardware used in our telemetry systems. One test system which was developed can be used to quickly determine if our communication link we are providing for the science payloads is functioning properly. Another system was developed to provide us with the ability to easily determine the status of one of our over the horizon communication links through a closed loop system. This test system has given us the capability to provide more field support to science groups than we were able to in years past. The trend of utilizing microcontrollers has taken place for a number of reasons. By using microcontrollers to fill these needs, it has given us the ability to quickly design and implement systems which meet flight critical needs, as well as perform many of the everyday tasks in LDB. This route has also allowed us to reduce the amount of time required for personnel to perform a number of the tasks required

  1. Quadricuspid aortic valve with ruptured sinus of Valsalva.

    Science.gov (United States)

    Akerem Khan, Shamruz Khan; Tamin, Syahidah Syed; Burkhart, Harold M; Araoz, Philip A; Young, Phillip M

    2013-02-01

    We present a case of a 24-year-old woman who was diagnosed with quadricuspid aortic valve with ruptured sinus of Valsalva. Quadricuspid aortic valve is a rare congenital cardiac anomaly. The recognition of quadricuspid aortic valve has clinical significance as it causes aortic valve dysfunction, and is often associated with other congenital cardiac abnormalities. We showed the important role of multimodality imaging in diagnosing a quadricuspid aortic valve associated with ruptured sinus of Valsalva. PMID:22874066

  2. Genetic Algorithm for Analysis of Abdominal Aortic Aneurysms in Radiology Reports

    Energy Technology Data Exchange (ETDEWEB)

    Patton, Robert M [ORNL; Beckerman, Barbara G [ORNL; Treadwell, Jim N [ORNL; Potok, Thomas E [ORNL

    2010-01-01

    An abdominal aortic aneurysm is a problem in which the wall of the artery that supplies blood to the abdomen and lower extremities expands under pressure or balloons outward. Patients must undergo surgery to repair such aneurysm, and there is currently no known indicator of success or failure from this surgery. Our work uses a genetic algorithm to analyze radiology reports from these patients to look for common patterns in the language used as well as common features of both successful and unsuccessful surgieries. The results of the genetic algorithm show that patients with complications or unusual characteristics can be identified from a set of radiology reports without the use of search keywords, clustering, categorization, or ontology. This allows medical researchers to search and identify interesting patient records without the need for explicitly defining what interesting patient records are.

  3. Results of surgery for aortic regurgitation due to aortic valve prolapse.

    Directory of Open Access Journals (Sweden)

    Shigenobu,Masaharu

    1988-12-01

    Full Text Available The clinical, hemodynamic and pathological findings of 13 patients with aortic regurgitation due to aortic valve prolapse caused by advanced myxomatous degeneration were evaluated. Eleven patients showed a favorable outcome with no complications resulting from surgery. One patient died from aortic dissection, and another died suddenly from an unknown cause. Five patients had mitral valve prolapse as a complication. Ten patients (77% had a long-standing history of hypertension. Twelve patients (92% were male. None of the patients had the stigmata of Marfan's syndrome. All patients had marked myxomatous degeneration of the aortic valves without any inflammatory changes. Two patients showed microcalcification; 7 demonstrated moderate fibrosis. Five patients showed severe fragility of the cusps which appeared redundant, gelatinous and softened by degenerative changes. Myxomatous degeneration of the aortic valve is not rare, and, in fact, it may be one of the most common pathologic and clinical entities associated with pure aortic insufficiency.

  4. Hybrid treatment of recurring thoracoabdominal aortic aneurysm concomitant with retrograde type A aortic dissection

    Institute of Scientific and Technical Information of China (English)

    ZHANG Min-hong; GUO Wei; DU Xin; XIONG Jiang

    2010-01-01

    So far, standard therapy of complex thoracoabdominal aortic disease is open surgical repair requiring aortic clamping and replacement of the involved segment.Despite significant improvements, morbidity and mortality of open surgery remain high.I As a result, open surgery is often withheld owing to severe comorbidities of the patients. Endovascular technique has emerged as an alternative for treatment of these diseases in high risk patients,2 and has enlarged the options of treatment of complex aortic diseases. However, an endovascular approach alone is often deemed unsuitable for some complex aortic disorders because of the close proximity of the supraaortic or visceral branches. A hybrid open-endovascular approach has therefore been proposed as a viable alternative. We present here a unique patient with recurring thoracoabdominal aortic aneurysm (TAAA) concomitant with an aortic dissection (AD) treated by a hybrid open-endovascular approach.

  5. Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj;

    2015-01-01

    BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an option in certain high-risk surgical patients with severe aortic valve stenosis. It is unknown whether TAVR can be safely introduced to lower-risk patients. OBJECTIVES: The NOTION (Nordic Aortic Valve Intervention Trial) randomized...... clinical trial compared TAVR with surgical aortic valve replacement (SAVR) in an all-comers patient cohort. METHODS: Patients ≥ 70 years old with severe aortic valve stenosis and no significant coronary artery disease were randomized 1:1 to TAVR using a self-expanding bioprosthesis versus SAVR. The primary...... conduction abnormalities requiring pacemaker implantation, larger improvement in effective orifice area, more total aortic valve regurgitation, and higher New York Heart Association functional class at 1 year. SAVR-treated patients had more major or life-threatening bleeding, cardiogenic shock, acute kidney...

  6. National Report France: The French Balloon Programme 2013-2016

    Science.gov (United States)

    Dubourg, V.; Vassaux, D.; Vargas, A.; Cocquerez, P.; Louvel, S.; Douchin, F.; Saccocio, M.; Mirc, F.

    2015-09-01

    With over 50 years' experience in the field, the French Centre National dEtudes Spatiales (CNES) goes on supporting a significant scientific ballooning program. In particular so because balloons still give a unique access to near space science. Over the past 6 years, most of the systems, beginning by the Zero Pressure Balloons, had to be renewed to comply with more stringent Safety constraints and to growing performance and reliability requirements from the scientific missions. This paper will give an overview of the CNES new capabilities and services for operational balloon activities, and their availability status. The scientific launch campaigns of the past two years will be presented. A focus will be made on the results of the Stratoscience 2014 flight campaign from Timmins, Ontario, using the NOSYCA command and control system for zero pressure balloons, qualified in 2013. The ChArMEx campaign (Chemistry-AeRosol Mediterranean Experiment) performed in 2013 from the Baleares islands and from the south of France, with Boundary Layer Pressurized Balloons will also be presented as well as the LOAC-VOLTAIRE experiment, carried out from Aire-sur-l'Adour (France), through the flights of 20 instrumented light expandable balloons. An outlook of the new stratospheric long duration flight systems currently studied at CNES will be given. The scientific launch campaigns and the main payloads in the study for the near future will also be presented.

  7. Graph-Based Path-Planning for Titan Balloons

    Science.gov (United States)

    Blackmore, Lars James; Fathpour, Nanaz; Elfes, Alberto

    2010-01-01

    A document describes a graph-based path-planning algorithm for balloons with vertical control authority and little or no horizontal control authority. The balloons are designed to explore celestial bodies with atmospheres, such as Titan, a moon of Saturn. The algorithm discussed enables the balloon to achieve horizontal motion using the local horizontal winds. The approach is novel because it enables the balloons to use arbitrary wind field models. This is in contrast to prior approaches that used highly simplified wind field models, such as linear, or binary, winds. This new approach works by discretizing the space in which the balloon operates, and representing the possible states of the balloon as a graph whose arcs represent the time taken to move from one node to another. The approach works with arbitrary wind fields, by looking up the wind strength and direction at every node in the graph from an arbitrary wind model. Having generated the graph, search techniques such as Dijkstra s algorithm are then used to find the set of vertical actuation commands that takes the balloon from the start to the goal in minimum time. In addition, the set of reachable locations on the moon or planet can be determined.

  8. Valvular Aortic Stenosis: A Proteomic Insight

    Directory of Open Access Journals (Sweden)

    Fernando Vivanco

    2010-02-01

    Full Text Available Calcified aortic valve disease is a slowly progressive disorder that ranges from mild valve thickening with no obstruction of blood flow, known as aortic sclerosis, to severe calcification with impaired leaflet motion or aortic stenosis. In the present work we describe a rapid, reproducible and effective method to carry out proteomic analysis of stenotic human valves by conventional 2-DE and 2D-DIGE, minimizing the interference due to high calcium concentrations. Furthermore, the protocol permits the aortic stenosis proteome to be analysed, advancing our knowledge in this area. Summary: Until recently, aortic stenosis (AS was considered a passive process secondary to calcium deposition in the aortic valves. However, it has recently been highlighted that the risk factors associated with the development of calcified AS in the elderly are similar to those of coronary artery disease. Furthermore, degenerative AS shares histological characteristics with atherosclerotic plaques, leading to the suggestion that calcified aortic valve disease is a chronic inflammatory process similar to atherosclerosis. Nevertheless, certain data does not fit with this theory making it necessary to further study this pathology. The aim of this study is to develop an effective protein extraction protocol for aortic stenosis valves such that proteomic analyses can be performed on these structures. In the present work we have defined a rapid, reproducible and effective method to extract proteins and that is compatible with 2-DE, 2D-DIGE and MS techniques. Defining the protein profile of this tissue is an important and challenging task that will help to understand the mechanisms of physiological/pathological processes in aortic stenosis valves.

  9. Ballooning of CANDU pressure tubes. Model assessment

    International Nuclear Information System (INIS)

    The transient creep equations used to analyze the possible ballooning and failure of Zr-2.5% Nb pressure tubes during a loss-of-coolant accident (LOCA) were developed and verified using as-received Zr-2.5% Nb pressure tube material. But in a CANDU reactor, the pressure tubes absorb deuterium and are exposed to a continuous neutron fluence. Consequently, a literature survey was done to determine how irradiation damage and deuterium might affect the creep rate and ductility of Zr-2.5% Nb pressure tubes in the temperature range from 600 to 800 degrees C. It was found that irradiation damage, dissolved deuterium and deuteride blisters could possibly affect the creep rate and ductility of ZR-2.5% Nb pressure tubes in this temperature range, but deuteride platelets are expected to have little effect. Further tests are required to determine the effect of irradiation damage and deuterium on the creep rate and ductility of pressure tubes

  10. The Norwegian Sounding Rocket and Balloon Program

    Science.gov (United States)

    Skatteboe, Rolf

    2001-08-01

    The status and recent developments of the Norwegian Sounding Rocket and Balloon Program are presented with focus on national activities and recent achievements. The main part of the Norwegian program is sounding rocket launches conducted by Andøya Rocket Range from the launch facilities on Andøya and at Svalbard. For the majority of the programs, the scientific goal is investigation of processes in the middle and upper atmosphere. The in situ measurements are supplemented by a large number of ground-based support instruments located at the ALOMAR Observatory. The ongoing and planned projects are described and the highlights of the latest completed projects are given. The scientific program for the period 2001-2003 will be reviewed. Several new programs have been started to improve the services available to the international science comunity. The Hotel Payload project and MiniDusty are important examples that will be introduced in the paper. Available space related infrastructure is summarized.

  11. Intragastric balloon: ethics, medical need and cosmetics.

    Science.gov (United States)

    Kotzampassi, Katerina; Shrewsbury, Anne D

    2008-01-01

    The development of the intragastic balloon as a safe, noninvasive, alternative method to weight reduction raises all the ethical questions routinely faced by practitioners of other forms of cosmetic surgery. In the case of the morbidly, severely or merely obese, the surgeon is faced with a medical decision in a situation defined by medical parameters. The case of the overweight or normal may, however, create an ethical dilemma in which the doctor is forced to make decisions of a nonmedical nature, for which his training has not prepared him, and relating essentially to his personal attitudes and moral beliefs, culture and the recognition that 'if I don't, somebody else--possibly less competent--will'.

  12. Effect of parameter variations on the hemodynamic response under rotary blood pump assistance.

    Science.gov (United States)

    Lim, Einly; Dokos, Socrates; Salamonsen, Robert F; Rosenfeldt, Franklin L; Ayre, Peter J; Lovell, Nigel H

    2012-05-01

    Numerical models, able to simulate the response of the human cardiovascular system (CVS) in the presence of an implantable rotary blood pump (IRBP), have been widely used as a predictive tool to investigate the interaction between the CVS and the IRBP under various operating conditions. The present study investigates the effect of alterations in the model parameter values, that is, cardiac contractility, systemic vascular resistance, and total blood volume on the efficiency of rotary pump assistance, using an optimized dynamic heart-pump interaction model previously developed in our laboratory based on animal experimental measurements obtained from five canines. The effect of mean pump speed and the circulatory perturbations on left and right ventricular pressure volume loops, mean aortic pressure, mean cardiac output, pump assistance ratio, and pump flow pulsatility from both the greyhound experiments and model simulations are demonstrated. Furthermore, the applicability of some of the previously proposed control parameters, that is, pulsatility index (PI), gradient of PI with respect to pump speed, pump differential pressure, and aortic pressure are discussed based on our observations from experimental and simulation results. It was found that previously proposed control strategies were not able to perform well under highly varying circulatory conditions. Among these, control algorithms which rely on the left ventricular filling pressure appear to be the most robust as they emulate the Frank-Starling mechanism of the heart. PMID:22489771

  13. Anatomics Knowledges of Aortic Root in the Transcatheter Aortic Valve Implantation.

    OpenAIRE

    Marcelo Cerezo; Omar Bertani; Gisela Panciroli; Sebastián Duhalde; Karina Ferreira; Luciano Honaine

    2010-01-01

    The Aortic Valve is a valvular system that bears different high pressure forces. It takes part of a complex structure called Aortic Root. Nowadays, anatomic knowledge has taken a preponderant role, due to the use of the Transcatether Aortic Valve Implant (TAVI). To describe the patient´s characteristics which exclude them of the TAVI for anatomic reasons in cadaveric dissections and transthoracic echocardiograms. A descriptive retrospective analysis of 67 individuals was performed and divided...

  14. Validation of IASI ozone profiles, using balloon sounding data

    OpenAIRE

    Delcloo, Andy; Hurtmans, Daniel; Coheur, Pierre-François; Clerbaux, Cathy

    2011-01-01

    Here we present a validation study of IASI vertical ozone profiles. This has been done using balloon ozone sonde data, which have a vertical resolution of about 100 m and measures ozone from the surface up to an altitude of about 30 km. IASI vertical ozone profiles are given as partial ozone columns [in DU per layer] between varying pressure levels. To validate the satellite derived ozone layers with the balloon ozone sounding data we integrate the ozone measured by the balloon ozone sounding...

  15. Balloon-dilatation of esophageal strictures in children

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, A.; Ingemann Jensen, L.; Mauritzen, K.

    1986-07-01

    Dilatation of benign esophageal strictures by means of a balloon-catheter is a well-established procedure in adults. This method is also useful in children. The technique is described and the results of treatment in 10 children are reported. In all our patients the stricture developed after an operation for esophageal atresia with an end-to-end anastomosis. Dilatation with a balloon-catheter seems to have the same or an even better effect than the traditional dilatation with bougies. Complications following balloon-dilatations have been few and negligible in this series and dilatations can be performed using sedation instead of general anaesthesia. Therefore, this method is recommended.

  16. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  17. Results of the first EUSO-Balloon flight

    Science.gov (United States)

    Miyamoto, H.; Bertaina, M.; JEM-EUSO Collaboration

    2016-05-01

    EUSO-Balloon, a balloon-borne diffractive fluorescence telescope, was launched by the French Space Agency ONES from the Timmins base in Ontario (Canada) on August 25th in 2014. After reaching the floating altitude of about 38 km, EUSO-Balloon imaged the UV background for more than 5 hours before descending to ground using the key technologies of JEM-EUSO. A detailed and precise measurement of the UV background in different atmospheric and ground conditions was achieved. The instrument proved the capability of detecting Extensive Air Showers (EAS) by observing laser tracks with similar characteristics. This contribution will summarise the first results obtained concerning all the topics described above.

  18. An investigation of electrostatically deposited radionuclides on latex balloons

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.; Caly, A., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2012-07-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  19. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  20. Management of Traumatic Aortic and Splenic Rupture in a Patient With Ascending Aortic Aneurysm.

    Science.gov (United States)

    Topcu, Ahmet Can; Ciloglu, Ufuk; Bolukcu, Ahmet; Dagsali, Sabri

    2016-08-01

    Traumatic aortic rupture is rupture of all or part of the aortic wall, mostly resulting from blunt trauma to the chest. The most common site of rupture is the aortic isthmus. Traumatic rupture of the ascending aorta is rare. A 62-year-old man with a family history of ascending aortic aneurysm was referred to our hospital after a motor vehicle accident. He had symptoms of cardiogenic shock. A contrast-enhanced computed tomographic scan revealed rupture of the proximal ascending aorta and an ascending aortic aneurysm with a diameter of 55 mm at the level of the sinuses of Valsalva. Transthoracic echocardiography at the bedside revealed severe aortic valvular insufficiency. We performed a successful Bentall procedure. During postoperative recovery, the patient experienced a cerebrovascular accident. Transesophageal echocardiography did not reveal thrombosis of the mechanical prosthesis. The patient's symptoms resolved in time, and he was discharged from the hospital on postoperative day 47 without any sequelae. He has been symptom free during a 6-month follow-up period. We suggest that individuals who have experienced blunt trauma to the chest and have symptoms of traumatic aortic rupture and a known medical history of ascending aortic aneurysm should be evaluated for a rupture at the ascending aorta and the aortic isthmus. PMID:27449463

  1. Combined surgical and catheter-based treatment of extensive thoracic aortic aneurysm and aortic valve stenosis

    DEFF Research Database (Denmark)

    De Backer, Ole; Lönn, Lars; Søndergaard, Lars

    2015-01-01

    endovascular aneurysm repair (TEVAR) has changed and extended management options in thoracic aorta disease, including in those patients deemed unfit or unsuitable for open surgery. Accordingly, transcatheter aortic valve replacement (TAVR) is increasingly used to treat patients with symptomatic severe aortic......An extensive thoracic aortic aneurysm (TAA) is a potentially life-threatening condition and remains a technical challenge to surgeons. Over the past decade, repair of aortic arch aneurysms has been accomplished using both hybrid (open and endovascular) and totally endovascular techniques. Thoracic...

  2. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  3. Types of Breast Pumps

    Science.gov (United States)

    ... breast-shield. Some experts discourage the use of bicycle horn pumps because they may be difficult to clean and dry. Battery-Powered and Electric Pumps A powered breast pump uses batteries or a cord plugged into an electrical outlet to power a small motorized pump that ...

  4. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  5. Medical image of the week: aortic ring

    Directory of Open Access Journals (Sweden)

    Wong C

    2014-10-01

    Full Text Available No abstract available. Article truncated after 150 words. A 78 year old man presented with altered mental status and was found to have an intraventricular hemorrhage. He was intubated for airway protection. On the post-intubation chest radiograph (Figure 1, the patient was noted to have a widening of the right paratracheal stripe. A CT chest (Figure 2 was obtained to characterize this finding and revealed an aortic ring which encircles the trachea and esophagus. Vascular rings are uncommon congenital abnormalities, accounting for approximately 1% of congenital heart disease. Complete vascular rings can occur with a right aortic arch with a ligamentum arteriosum or with a double aortic arch, such as with our patient (1. This ring can cause airway compression, stridor, esophageal compression, or no symptoms at all. As the embryo develops, the left fourth pharyngeal arch normally persists to become the aortic arch while the right fourth pharyngeal arch regresses. If both fourth pharyngeal arches persist, a ...

  6. Aortic aneurysm secondary to umbilical artery catheterization

    International Nuclear Information System (INIS)

    A 14-month-girl presented with an asymptomatic posterior mediastinal mass. She had a history of prematurity, umbilical artery catheterization, and sepsis. The diagnosis of aortic aneurysm was made by dynamic computed tomography. The aneurysm was successfully resected. (orig.)

  7. Type B Aortic Dissection: Management Updates

    Directory of Open Access Journals (Sweden)

    Naghmeh Moshtaghi

    2009-12-01

    Full Text Available Acute aortic dissection (AAD is the most frequent catastrophic event of the aorta; it occurs nearly three times as frequently as the rupture of abdominal aortic aneurysm. Sixty percent of dissection cases are classified as proximal or type A and 40% as distal or type B, according to the Stanford Classification. The most frequent causes of death in acute type B dissection are aortic rupture and malperfusion syndrome.We herein review recent data suggesting different management modalities of type B aortic dissection, including medical, surgical, and endovascular treatments. Although medical therapy is still the standard approach in uncomplicated cases, there are subgroups of patients who may benefit from endovascular management. Endovascular techniques or surgery are valuable options for complicated cases. Hybrid suites, multidisciplinary approaches, and good imaging techniques can be considered as the key to success in this regard.

  8. Valve selection in aortic valve endocarditis

    Science.gov (United States)

    Zubrytska, Yana

    2016-01-01

    Aortic prosthetic valve endocarditis (PVE) is a potentially life-threatening disease. Mortality and incidence of infective endocarditis have been reduced in the past 30 years. Medical treatment of aortic PVE may be successful in patients who have a prompt response after antibiotic treatment and who do not have prosthetic dysfunction. In advanced stages, antibiotic therapy alone is insufficient to control the disease, and surgical intervention is necessary. Surgical treatment may be lifesaving, but it is still associated with considerable morbidity and mortality. The aim of surgery is to perform a radical excision of all infected and necrotic tissue, reconstruction of the left ventricle outflow tract, and replacement of the aortic valve. There is no unanimous consensus on which is the optimal prosthesis to implant in this context, and several surgical techniques have been suggested. We aim to analyze the efficacy of the surgical treatment and discuss the issue of valve selection in patients with aortic valve endocarditis.

  9. Dissecting aortic aneurysm in maintenance hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Ounissi M

    2009-01-01

    Full Text Available The dissecting aortic aneurysm (DAA is a rare pathology that may result in fatal outcome. We report follow up of three cases of DAA patients undergoing maintenance hemo-dialysis who were managed conservatively.

  10. A rare cause of recurrent aortic dissection.

    Science.gov (United States)

    Agrawal, Yashwant; Gupta, Vishal

    2016-07-01

    We report the case of a 19-year-old man with a history of Loeys-Dietz syndrome (LDS), which was diagnosed when he had a Stanford type A aortic dissection. He also had multiple aneurysms including ones in the innominate, right common carotid, and right internal mammary arteries. He had had multiple procedures including Bentall's procedure, repeat sternotomy with complete arch and valve replacement, and coil embolization of internal mammary artery aneurysm in the past. His LDS was characterized by gene mutation for transforming growth factor-β receptor 1. He presented to our facility with sudden onset of back pain, radiating to the right shoulder and chest. He was diagnosed with Stanford type B aortic dissection and underwent thoracic aorta endovascular repair for his aortic dissection. This case represents the broad spectrum of pathology associated with LDS where even with regular surveillance and aggressive medical management the patient developed Stanford B aortic dissection. PMID:27358537

  11. CLIMB: cosmic light isotopes and muons with balloons

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, M. E-mail: pearce@particle.kth.se; Adriani, O.; Boezio, M.; Bonvicini, V.; Carlson, P.; Mocchiutti, E.; Papini, P.; Straulino, S.; Vacchi, A.; Vannuccini, E.; Zampa, G.; Zampa, N

    2004-06-01

    A new balloon-borne experiment is proposed which will measure high-energy light isotopes at the top of the Earth's atmosphere and cosmic ray muons at fixed altitudes within the Earth's atmosphere.

  12. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    Science.gov (United States)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  13. Current status of intragastric balloon for obesity treatment

    Science.gov (United States)

    Kim, Seung Han; Chun, Hoon Jai; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae

    2016-01-01

    Endoscopic bariatric therapy may be a useful alternative to pharmacological treatment for obesity, and it provides greater efficacy with lower risks than do conventional surgical procedures. Among the various endoscopic treatments for obesity, the intragastric balloon is associated with significant efficacy in body weight reduction and relief of comorbid disease symptoms. Anatomically, this treatment is based on gastric space-occupying effects that increase the feeling of satiety and may also affect gut neuroendocrine signaling. The simplicity of the intragastric balloon procedure may account for its widespread role in obesity treatment and its applicability to various degrees of obesity. However, advances in device properties and procedural techniques are still needed in order to improve its safety and cost-effectiveness. Furthermore, verification of the physiological outcomes of intragastric balloon treatment and the clinical predictive factors for treatment responses should be considered. In this article, we discuss the types, efficacy, safety, and future directions of intragastric balloon treatment. PMID:27350727

  14. 10 meter Sub-Orbital Large Balloon Reflector (LBR) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Besides serving as a launch vehicle, the carrier balloon provides a stable mount for the enclosed telescope. Looking up, the LBR will serve as a telescope. Looking...

  15. Proposed techniques for launching instrumented balloons into tornadoes

    Science.gov (United States)

    Grant, F. C.

    1971-01-01

    A method is proposed to introduce instrumented balloons into tornadoes by means of the radial pressure gradient, which supplies a buoyancy force driving to the center. Presented are analytical expressions, verified by computer calculations, which show the possibility of introducing instrumented balloons into tornadoes at or below the cloud base. The times required to reach the center are small enough that a large fraction of tornadoes are suitable for the technique. An experimental procedure is outlined in which a research airplane puts an instrumented, self-inflating balloon on the track ahead of the tornado. The uninflated balloon waits until the tornado closes to, typically, 750 meters; then it quickly inflates and spirals up and into the core, taking roughly 3 minutes. Since the drive to the center is automatically produced by the radial pressure gradient, a proper launch radius is the only guidance requirement.

  16. Low Cost Variable Conductance Heat Pipe for Balloon Payload Project

    Data.gov (United States)

    National Aeronautics and Space Administration — While continuously increasing in complexity, the payloads of terrestrial high altitude balloons need a thermal management system to reject their waste heat and to...

  17. Anesthetic management of transcatheter aortic valve implantation

    OpenAIRE

    Annalisa Franco; Chiara Gerli; Laura Ruggeri; Fabrizio Monaco

    2012-01-01

    Transcatheter aortic valve implantation (TAVI) is an emergent technique for high-risk patients with aortic stenosis. TAVI poses significant challenges about its management because of the procedure itself and the population who undergo the implantation. Two devices are currently available and marketed in Europe and several other technologies are being developed. The retrograde transfemoral approach is the most popular procedure; nevertheless, it may not be feasible in patients with significant ...

  18. Surveillance intervals for small abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Bown, Matthew J; Sweeting, Michael J; Brown, Louise C;

    2013-01-01

    Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture.......Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture....

  19. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  20. Effect of age on aortic atherosclerosis

    Institute of Scientific and Technical Information of China (English)

    Michael A. Chen; Miwa Kawakubo; Patrick M. Colletti; Dongxiang Xu; Laurie LaBree Dustin; Robert Detrano; Stanley P Azen; Nathan D. Wong; Xue-Qiao Zhao

    2013-01-01

    Objective To examine the association of atherosclerosis burden in the survivors of an asymptomatic elderly cohort study and its relationship to other coronary risk factors (specifically, age) by evaluating aortic atherosclerotic wall burden by magnetic resonance imaging (MRI). Methods A total of 312 participants in an ongoing observational cohort study underwent cardiac and descending thoracic aorta imaging by MRI. Maximum wall thickness was measured and the mean wall thickness calculated. Wall/outer wall ratio was used as a normalized wall index (NWI) adjusted for artery size difference among participants. Percent wall volume (PWV) was calculated as NWI × 100. Results In this asymptomatic cohort (mean age: 76 years), the mean (SD) aortic wall area and wall thickness were 222 ± 45 mm2 and 2.7 ± 0.4 mm, respectively. Maximum wall thickness was 3.4 ± 0.6 mm, and PWV was 32% ± 4%. Women appeared to have smaller wall area, but after correcting for their smaller artery size, had significantly higher PWV than men (P = 0.03). Older age was associated with larger wall area (P = 0.04 for trend) with similar PWVs. However, there were no statistically significant associations between standard risk factors, Framingham global risk, or metabolic syndrome status, therapy for cholesterol or hypertension, coronary or aortic calcium score, and the aortic wall burden. Aortic calcification was associated with coronary calcification. Conclusions Asymptomatic elderly in this cohort had a greater descending thoracic aortic wall volume that correlated with age, and women had a significantly increased PWV compared to men. In these survivors, the atherosclerotic aortic wall burden was not significantly associated with traditional risk factors or with coronary or aortic calcium scores or coronary calcium progression. Results suggest that age, or as yet unidentified risk factor(s), may be responsible for the increase in atherosclerosis.

  1. Aortic Dissection Cases Presenting with Neurological Deficit

    Directory of Open Access Journals (Sweden)

    Sibel Mumcu

    2014-06-01

    Full Text Available Aortic dissection can be fatal in case of underdiagnosis, and early treatment is essential for the survival. Although acute onset of chest or back pain is most common presenting symptoms, some patients might present with atypical findings such as acute stroke, mesenteric ischaemia, renal failure or myocardial infarction. Here, we report two cases presenting emergency room with atypical findings of aortic dissection which diagnosis is made during etiologic work up for ischemic stroke.

  2. Glucose Suppresses Biological Ferroelectricity in Aortic Elastin

    OpenAIRE

    Liu, Yuanming; WANG, YUNJIE; Chow, Ming-Jay; Chen, Nataly Q.; Ma, Feiyue; Zhang, Yanhang; Li, Jiangyu

    2013-01-01

    Elastin is an intriguing extracellular matrix protein present in all connective tissues of vertebrates, rendering essential elasticity to connective tissues subjected to repeated physiological stresses. Using piezoresponse force microscopy, we show that the polarity of aortic elastin is switchable by an electrical field, which may be associated with the recently discovered biological ferroelectricity in the aorta. More interestingly, it is discovered that the switching in aortic elastin is la...

  3. Small Research Balloons in a Physics Course for Education Majors

    Science.gov (United States)

    Bruhweiler, F. C.; Verner, E.; Long, T.; Montanaro, E.

    2013-12-01

    At The Catholic Univ. of America, we teach an experimental physics course entitled Physics 240: The Sun-Earth Connection, which is designed for the undergraduate education major. The emphasis is on providing hands-on experience and giving the students an exciting experience in physics. As part of this course, in the Spring 2013 semester, we instituted a project to plan, build, launch, and retrieve a small (~1.3 kg) research balloon payload. The payload flown was a small GPS unit that sent its position to an Internet site, a small wide-angle high-resolution video camera, and an analog refrigerator thermometer placed in the field of view of the camera. All data were stored on the camera sim-card. Students faced the problems of flying a small research balloon in the congested, densely populated Northeast Corridor of the US. They used computer simulators available on the Web to predict the balloon path and flight duration given velocities for the Jet Stream and ground winds, as well as payload mass and amount of helium in the balloon. The first flight was extremely successful. The balloon was launched 140 km NW of Washington DC near Hagerstown, MD and touched down 10 miles (16 km) NW of York, PA, within 1.6 km of what was predicted. The balloon reached 73,000 ft (22,000 m) and the thermometer indicated temperatures as low as -70 degrees Fahrenheit (-57 C) during the flight. Further balloon flights are planned in conjunction with this course. Additional exercises and experiments will be developed centered around these flights. Besides learning that science can be exciting, students also learn that science is not always easily predictable, and that these balloon flights give an understanding of many of problems that go into real scientific space missions. This project is supported in part by an educational supplement to NASA grant NNX10AC56G

  4. The Hubble party balloon and the expanding universe

    Science.gov (United States)

    Zendri, G.; Rosi, T.; Oss, S.

    2016-09-01

    We show that the metaphor of the inflated balloon used to describe expanding space-time according to the Hubble law can be transformed into a simple laboratory experiment. We obtain, in terms of measured recession speeds and distances of ink dots drawn on a party balloon, easy renditions of various cosmological models, such as the static one and the Einstein-De Sitter universe.

  5. Recently patented and widely used valves for transcatheter aortic valve implantation.

    Science.gov (United States)

    Neragi-Miandoab, Siyamek; Skripochnik, Edvard; Michler, Robert E

    2012-12-01

    Aortic stenosis (AS) is a serious condition in the aging US and European populations. Management of a stenotic valve is crucial as it can become symptomatic quickly leading to ventricular deterioration and overall poor quality of life. Considering that AS is a disease of the elderly patient population, surgical intervention may not be well tolerated by some patients. Transcatheter aortic valve implantation (TAVI) has emerged as an alternative approach for patients who are unsuitable surgical candidates. Since the first balloon-expandable Edwards SAPIEN valve (Edwards Lifesciences, Irvine, CA) was implanted by Dr. Cribier, many other valves have been introduced into clinical practice. Self-expanding valves such as the CoreValve ReValving system (Medtronic, Minneapolis, MN) for retrograde implantation and Symetis TX for antegrade and transapical implantation are the most frequently used self-expanding valves. The SAPIEN valve, on the other hand can be implanted both antegrade as well as retrograde. Overall, the most widely used valves are the Edwards SAPIEN and the CoreValve, which have been implanted in more than 40,000 patients worldwide. The Symetis valve has shown promising results in small series in Europe and may be introduced to the US market in the near future. This manuscript will review these 3 recently patented valves and discuss some of the clinical results that are available. PMID:23095028

  6. Complications of Aortic Stenting in Patients below 20 Years Old: Immediate and Intermediate Follow-Up

    Directory of Open Access Journals (Sweden)

    Akbar Molaei

    2011-12-01

    Full Text Available Background: Optimal timing and mode of treatment for patients with coarctation of the aorta (COA remain controversial, particularly in children. Surgery, balloon dilatation, and stent implantation have all proven effective in the treatment of moderate or severe obstruction. The aim of this study was to investigate the complications of COA stenting angioplasty in pediatric patients. Methods: This retrospective, descriptive study was conducted on patients less than 20 years of age who underwent aortic stenting angioplasty because of congenital COA in the pediatric catheterization laboratory of Rajaie cardiovascular, medical and research Center, Tehran between 2005 and 2010. Results: A total of 26 patients (18 [65.4%] males and 9 [34.6%] females with congenital COA who had undergone aortic stenting angioplasty were recruited. Nineteen (73.1% of these patients had native COA and 7 (26.9% had recurrent COA. Most of the early complications were minor and temporary; only one patient developed early major complications. During the follow-up, whereas none of the native group patients developed late complications, in the re-COA group 28.57% of the patients had re-stenosis and 14.28% had chronic systemic hypertension, requiring drug therapy. Conclusion: Our investigation into post-stenting complications in patients with native COA and re-COA showed that endovascular stenting could be an effective and safe method, even in young patients with native COA.

  7. Quantification of abdominal aortic deformation after EVAR

    Science.gov (United States)

    Demirci, Stefanie; Manstad-Hulaas, Frode; Navab, Nassir

    2009-02-01

    Quantification of abdominal aortic deformation is an important requirement for the evaluation of endovascular stenting procedures and the further refinement of stent graft design. During endovascular aortic repair (EVAR) treatment, the aortic shape is subject to severe deformation that is imposed by medical instruments such as guide wires, catheters, and, the stent graft. This deformation can affect the flow characteristics and morphology of the aorta which have been shown to be elicitors for stent graft failures and be reason for reappearance of aneurysms. We present a method for quantifying the deformation of an aneurysmatic aorta imposed by an inserted stent graft device. The outline of the procedure includes initial rigid alignment of the two abdominal scans, segmentation of abdominal vessel trees, and automatic reduction of their centerline structures to one specified region of interest around the aorta. This is accomplished by preprocessing and remodeling of the pre- and postoperative aortic shapes before performing a non-rigid registration. We further narrow the resulting displacement fields to only include local non-rigid deformation and therefore, eliminate all remaining global rigid transformations. Finally, deformations for specified locations can be calculated from the resulting displacement fields. In order to evaluate our method, experiments for the extraction of aortic deformation fields are conducted on 15 patient datasets from endovascular aortic repair (EVAR) treatment. A visual assessment of the registration results and evaluation of the usage of deformation quantification were performed by two vascular surgeons and one interventional radiologist who are all experts in EVAR procedures.

  8. [The effect of halothane and enflurane as well as of propanidid and ketamin on the aortic baroreceptor discharge of decerebrated cats (author's transl)].

    Science.gov (United States)

    Hagenau, W; Pietsch, D; Arndt, J O

    1976-07-01

    The effect of halothane, enflurane, propanidid and ketamine on the sensitivity of the aortic baroreceptors and its quantitative relationship with arterial pressure were studied in decerebrated cats. Receptor response curves (single baroreceptor fibres of the depressor nerve) were constructed by plotting the average discharge rate (spikes/sec) against the aortic mean pressure and the effect of the anaesthetics on them was analysed. The blood pressure was changed over wide ranges by inflating a balloon placed in the thoracic part of the descending aorta through a femoral artery. Receptor sensitivity increased with halothane and enflurane, yet it decreased with propanidid. It remained uneffected duringanesthesia with ketamine. Thus, different anesthetics act differently on the afferent impulse traffic of baroreceptors. The possible role of these effects on blood pressure control during anaesthesia is discussed.

  9. Development of a tiny tandem balloon system for atmospheric observation

    Science.gov (United States)

    Saito, Yoshitaka; Yamada, Kazuhiko; Fujiwara, Masatomo

    2016-07-01

    A tandem balloon system with a combination of a zero-pressure balloon on top and a super-pressure balloon on the bottom has a unique trajectory characteristic, with different flight altitudes between day and night and thus with ascending and descending motions at dawn and dusk, respectively. This characteristic provides a unique opportunity to explore the atmosphere, e.g., the upper tropospheric and lower stratospheric region with cross-tropopause measurements twice a day. We started development of a tiny tandem balloon system using a 10 m^{3} super-pressure balloon and a 100 m^{3} zero-pressure balloon, with a capability of carrying 3 kg of payload. One of the scientific targets is to measure water vapor, cloud particles, and temperature around the tropical tropopause which is the entry point of the stratospheric and mesospheric meridional circulation. For the data transfer, the iridium satellite communication module, SBD9603 is used. In this paper, the current status of the development will be reported.

  10. Repositioning of an Intraventricular Dislocated Aortic Valve during Transcatheter Aortic Valve Implantation

    NARCIS (Netherlands)

    Natour, Ehsan; Douglas, Yvonne L.; Jainandunsing, Jayant S.; Schurer, Remco A. J.; van der Werf, Hendrik W.; van den Heuvel, Ad F. M.

    2014-01-01

    The case is presented of a 75-year-old man referred for transcatheter aortic valve implantation. During the procedure the prosthetic aortic valve became dislocated into the left ventricle shortly after expansion. The subsequent steps taken to reposition the valve using only materials at hand are des

  11. Turner's syndrome associated with bicuspid aortic stenosis and dissecting aortic aneurysm

    OpenAIRE

    Slater, D N; Grundman, M. J.; Mitchell, L

    1982-01-01

    A case of Turner's syndrome is described associated with bicuspid aortic stenosis and fatal rupture of a thoracic dissecting aortic aneurysm. Histology of the aneurysm showed severe cystic medial necrosis. This association has not been previously described in the absence of coarctation.

  12. ALTERNATIVE METHOD OF SURGICAL CORRECTION OF DISSECTING AORTIC ANEURYSMS WITH AORTIC INSUFFIECIENCY

    Directory of Open Access Journals (Sweden)

    M. L. Semenovsky

    2009-01-01

    Full Text Available Patients with dissecting aortic aneurysm and associated acute aortic insufficiency form a group of seriously ill patients with significant cardiac failure, generally involving other organs and systems. It justifies an attempt to reduce a surgical risk, by using more sparing procedures, including supracoronary replacement of the ascending aorta with its root reconstruction. The latter has been performed in 27 patients (mean 54,5 ± 2,1 years with dissecting aortic aneurysm and aortic valvular insufficiency in 1996 to 2009. The major etiological factor was atherosclerosis (88%/ Seventeen (63%, 6 (22,2% and 4 (16% had types I, IIA and II dissection, respectively. Overall hospital mortality was 11%. In late period, progressive aneurysm dissection needed reinterventions in 2 cases. The competence of the reconstructed aortic valve was satisfactory both just after surgery and throughout the follow-up. Indications for this option of chronic correction, surgical techniques, and immediate and long-term results are outlined. 

  13. Abdominal Aortic Diameter Is Increased in Males with a Family History of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Mejnert Jørgensen, Trine; Houlind, K; Green, A;

    2014-01-01

    OBJECTIVE: To investigate, at a population level, whether a family history of abdominal aortic aneurysm (AAA) is independently related to increased aortic diameter and prevalence of AAA in men, and to elucidate whether the mean aortic diameter and the prevalence of AAA are different between...... participants with male and female relatives with AAA. DESIGN: Observational population-based cross-sectional study. MATERIALS: 18,614 male participants screened for AAA in the VIVA-trial 2008-2011 with information on both family history of AAA and maximal aortic diameter. METHODS: Standardized ultrasound scan...... measurement of maximum antero-posterior aortic diameter. Family history obtained by questionnaire. Multivariate regression analysis was used to test for confounders: age, sex, smoking, comorbidity and medication. RESULTS: From the screened cohort, 569 participants had at least one first degree relative...

  14. Measurement and determinants of infrarenal aortic thrombus volume

    Energy Technology Data Exchange (ETDEWEB)

    Golledge, Jonathan; Wolanski, Philippe [James Cook University, The Vascular Biology Unit, Townsville, Queensland (Australia); Townsville Hospital, Townsville, Queensland (Australia); Parr, Adam [James Cook University, The Vascular Biology Unit, Townsville, Queensland (Australia); Buttner, Petra [James Cook University, School of Public Health and Tropical Medicine, Townsville, Queensland (Australia)

    2008-09-15

    Intra-luminal thrombus has been suggested to play a role in the progression of abdominal aortic aneurysm (AAA). The aims of this study were twofold. Firstly, to assess the reproducibility of a computer tomography (CT)-based technique for measurement of aortic thrombus volume. Secondly, to examine the determinants of infrarenal aortic thrombus volume in a cohort of patients with aortic dilatation. A consecutive series of 75 patients assessed by CT angiography with maximum aortic diameter {>=}25 mm were recruited. Intra-luminal thrombus volume was measured by a semi-automated workstation protocol based on a previously defined technique to quantitate aortic calcification. Intra- and inter-observer reproducibility were assessed using correlation coefficients, coefficient of variation and Bland-Altman plots. Infrarenal aortic thrombus volume percentage was related to clinical, anatomical and blood characteristics of the patients using univariate and multivariate tests. Infrarenal aortic thrombus volume was related to the severity of aortic dilatation assessed by total aortic volume (r=0.87, P<0.0001) or maximum aortic diameter (r=0.74, P< 0.0001). We therefore examined the clinical determinates of aortic thrombus expressed as a percentage of total aortic volume. Aortic thrombus percentage was negatively correlated with serum high density lipoprotein (HDL, r=-0.31). By ordinal multiple logistic regression analysis serum HDL below median ({<=}1.2 mM) was associated with aortic thrombus percentage in the upper quartile adjusting for other risk factors (odds ratio 5.3, 95% CI 1.1-25.0). Infrarenal aortic thrombus volume can be measured reproducibly on CT. Serum HDL, which can be therapeutically raised, may play a role in discouraging aortic thrombus accumulation with implications in terms of delaying progression of AAA. (orig.)

  15. Burn Injury Arise From Flying Balloon Toys

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2007-08-01

    Full Text Available Many of peoples are faced minor or major burn injuries in their life. Even the most widespread burn cause is flame injuries, too different burn cause pointed out in literature like Acetylen burns. The cases which imply in literature, mostly causes from explosion of high pressure acetylene tube, metal oxygene patch flame or carbide lamp using from cave explorers. An interesting acetylene burn cause in Turkey was publised by the authors. This cases was to come into being from flying toy balloons flame. 80 person was injured from flying toy ballons flame in a meeting in 2002. Although this potential risks of acetylene, helium have not any of some risk. But helium was provided from other countries and have more price. The injuries which caused from acetylene burns like 1st -2nd degree burns. Consequently that was known helium is more avaliable for using in toy sector, and never cause burn injuries like this. [TAF Prev Med Bull. 2007; 6(4: 291-296

  16. Burn Injury Arise From Flying Balloon Toys

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2007-08-01

    Full Text Available Many of peoples are faced minor or major burn injuries in their life. Even the most widespread burn cause is flame injuries, too different burn cause pointed out in literature like Acetylen burns. The cases which imply in literature, mostly causes from explosion of high pressure acetylene tube, metal oxygene patch flame or carbide lamp using from cave explorers. An interesting acetylene burn cause in Turkey was publised by the authors. This cases was to come into being from flying toy balloons flame. 80 person was injured from flying toy ballons flame in a meeting in 2002. Although this potential risks of acetylene, helium have not any of some risk. But helium was provided from other countries and have more price. The injuries which caused from acetylene burns like 1st -2nd degree burns. Consequently that was known helium is more avaliable for using in toy sector, and never cause burn injuries like this. [TAF Prev Med Bull 2007; 6(4.000: 291-296

  17. Alpha particle effects on MHD ballooning

    International Nuclear Information System (INIS)

    During the period, as the first step towards the goal of detail understanding of the effects of alpha particle on MHD Ballooning Modes, a new numerical approach to investigate the stability of low-frequency fluctuations in high temperature tokamaks was developed by solving the gyrokinetic equations for the ion and electron directly as an initial value problem. The advantage of this approach is the inclusion of many important kinetic features of the problem without approximations and computationally more economical than particle-pushing simulation. The ion-temperature-gradient-mode was investigated to benchmark this new simulation technique. Previous results in literature were recovered. Both the adiabatic electron model and the full drift-kinetic electron model are studied. Numerical result shows that the full drift-kinetic electron model is more unstable. The development of subcycling technique to handle the fast electron bounce time is particularly significant to apply this new approach to the alpha particle problem since alpha particle bounce frequency is also significantly higher than the mode frequency. This new numerical technique will be the basis of future study of the microstability in high temperature tokamaks with alpha particles (or any energetic species). 15 refs., 13 figs

  18. Large electromagnetic pumps. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kilman, G.B.

    1976-01-01

    The development of large electromagnetic pumps for the liquid metal heat transfer systems of fission reactors has progressed for a number of years. Such pumps are now planned for fusion reactors and solar plants as well. The Einstein-Szilard (annular) pump has been selected as the preferred configuration. Some of the reasons that electromagnetic pumps may be preferred over mechanical pumps and why the annular configuration was selected are discussed. A detailed electromagnetic analysis of the annular pump, based on slug flow, is presented. The analysis is then used to explore the implications of large size and power on considerations of electromagnetic skin effect, geometric skin effect and the cylindrical geometry.

  19. Optical coherence tomography monitoring of angioplasty balloon inflation in a deployment tester

    Science.gov (United States)

    Azarnoush, Hamed; Vergnole, Sébastien; Bourezak, Rafik; Boulet, Benoit; Lamouche, Guy

    2010-08-01

    We present an innovative integration of an intravascular optical coherence tomography probe into a computerized balloon deployment system to monitor the balloon inflation process. The high-resolution intraluminal imaging of the balloon provides a detailed assessment of the balloon quality and, consequently, a technique to improve the balloon manufacturing process. A custom-built swept-source optical coherence tomography system is used for real-time imaging. A semicompliant balloon with a nominal diameter of 4 mm is fabricated for the experiments. Imaging results correspond to balloon deployment in air and inside an artery phantom. A characterization of the balloon diameter, wall thickness, compliance, and elastic modulus is provided, based on image segmentation. Using the images obtained from the probe pullback, a three-dimensional visualization of the inflated balloon is presented.

  20. Aneurismas da aorta Aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Januário M Souza

    1992-09-01

    Full Text Available Entre janeiro de 1979 e janeiro de 1992, foram realizadas 212 operações para correção de aneurismas e de dissecções da aorta. Neste trabalho serão analisados 104 procedimentos cirúrgicos (em 97 pacientes para correção de aneurismas. A idade dos pacientes variou de 14 a 79 anos (média 59,5 anos e o sexo predominante foi o masculino, com 75 pacientes. Os aneurismas localizavam-se na aorta ascendente em 46 pacientes, na croça em 8, na aorta descendente em 8, na aorta toráco-abdominal em 8, na aorta abdominal em 21, na aorta descendente e abdominal em 2, na aorta ascendente e tóraco-abdominal em 2, na aorta ascendente e descendente em 1, na aorta ascendente, croça e descendente em 1. Doenças cardiovasculares associadas estavam presentes em 39 pacientes, sendo valvopatia aórtica em 18 (excluídos os pacientes com ectasiaânulo-aórtíca, insuficiência coronária em 17, coarctação da aorta em 2, persistência do canal arterial em 1 e valvopatia mitral e aórtica em 1. A mortalidade imediata (hospitalar e/ou 30 dias foi de 14,4%, sendo de 27,7% (5/18 para pacientes com mais de 70 anos e de 11,3% (9/79 para pacientes com idade inferior a 70 anos. Os aneurismas localizados na aorta ascendente e croça foram operados como o auxílio de circulação extracorpórea. Parada circulatória e hipotermia profunda foram utilizadas em todos os pacientes com aneurisma da croça. O estudo tomográfico e angiográfico deve ser de toda a aorta, pela possibilidade de aneurismas de localizações múltiplas.Among 212 patients undergoing operation for aortic aneurysm and aortic dissection between January 1979 and January 1992, 97 were operated on for aneurysms. The aneurysms were localized in: ascending aorta in 46 patients, transverse aortic arch in 8, descending aorta in 8, thoracoabdominal aorta in 8, abdominal (infrarenal aorta in 21, descending and abdominal aorta in 2, ascending and thoracoabdominal aorta in 2, ascending and descending in 1

  1. Vasopressor mechanisms in acute aortic coarctation hypertension

    Directory of Open Access Journals (Sweden)

    Salgado H.C.

    1997-01-01

    Full Text Available Angiotensin II (ANG II and vasopressin (AVP act together with the mechanical effect of aortic constriction in the onset of acute aortic coarctation hypertension. Blockade of ANG II and AVP V1 receptors demonstrated that ANG II acts on the prompt (5 min rise in pressure whereas AVP is responsible for the maintenance (30-45 min of the arterial pressure elevation during aortic coarctation. Hormone assays carried out on blood collected from conscious rats submitted to aortic constriction supported a role for ANG II in the early stage and a combined role for both ANG II and AVP in the maintenance of proximal hypertension. As expected, a role for catecholamines was ruled out in this model of hypertension, presumably due to the inhibitory effect of the sinoaortic baroreceptors. The lack of afferent feedback from the kidneys for AVP release from the central nervous system in rats with previous renal denervation allowed ANG II to play the major role in the onset of the hypertensive response. Median eminence-lesioned rats exhibited a prompt increase in proximal pressure followed by a progressive decline to lower hypertensive levels, revealing a significant role for the integrity of the neuroaxis in the maintenance of the aortic coarctation hypertension through the release of AVP. In conclusion, the important issue raised by this model of hypertension is the likelihood of a link between some vascular territory - probably renal - below the coarctation triggering the release of AVP, with this vasoconstrictor hormone participating with Ang II and the mechanical effect of aortic constriction in the acute aortic coarctation hypertension

  2. Atherosclerotic Aortic Plaques Detected by Transesophageal Echocardiography

    Institute of Scientific and Technical Information of China (English)

    赵云; 朱文玲; 倪超; 郭丽琳; 曾勇; 方理刚

    2002-01-01

    Objective To evaluate the predictive value of atherosclerotic aortic plaques in coronary artery disease (CAD) Methods In 50patients with suspected coronary artery disease, transesophageal echocardiography was performed to examine their thoracic aortas 2 weeks before or after coronary angiography. In the cases of coronary angiography studied, stenosis of the coronary artery ≥ 50 % was considered to be due to coronary artery disease,whereas the thickness of the intima ≥ 1.3 mm was taken to be the criteria for the presence of an atherosclerotic aortic plaque on the transesophageal echocardiographic test. Results Among the 50 patients, 37 cases were diagnosed as CAD and 13 cases were considered to be normal. The plaques of the thoracic aorta were observed in 34cases in the CAD group and 3 cases in the normal group. The sensitivity and specificity of aortic plaques for CAD were 91.9 % and 76.9%, respectively. The positive and negative predictive values of the aortic plaques for CAD were 91.9% and 76.9%, respectively. The accuracy was 88.0%. 80 percent of the patients with single- yes sel disease had thoracic aortic plaques, 92 percent of the patients with two-vessel disease and 100 percent of the patients with three-vessel disease had thoracic aortic plaques. There was a significant difference in the thickness of aortic intimas between the normal group and the CAD group. Conclusions Detectingatherosclerotic plaques in the thoracic aorta with transesophageal echocardiography may be of great value in predicting the presence and extent of coronary artery disease.

  3. External aortic wrap for repair of type 1 endoleak

    Directory of Open Access Journals (Sweden)

    Anastasia Dean

    2014-01-01

    CONCLUSION: Provided certain anatomical features are present, an external aortic wrap is a useful and successful option to manage type 1 endoleak in high-risk patients who are unsuitable for aortic clamping.

  4. Outcomes after transcatheter aortic valve implantation: transfemoral versus transapical approach

    NARCIS (Netherlands)

    Ewe, S.H.; Delgado, V.; Ng, A.C.; Antoni, M.L.; Kley, F. van der; Marsan, N.A.; Weger, A. de; Tavilla, G.; Holman, E.R.; Schalij, M.J.; Bax, J.J.

    2011-01-01

    BACKGROUND: Transcatheter aortic valve implantation is commonly implanted through a transfemoral (TFA) or transapical approach (TAA) for patients with severe aortic stenosis. This study aimed to describe the clinical and echocardiographic outcomes of TFA versus TAA. METHODS: Clinical and echocardiog

  5. Development of a super-pressure balloon with a diamond-shaped net --- result of a ground inflation test of a 2,000 cubic-meter balloon ---

    Science.gov (United States)

    Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma

    2016-07-01

    A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.

  6. Proton pump inhibitors

    Science.gov (United States)

    Proton pump inhibitors (PPIs) are medicines that work by reducing the amount of stomach acid made by ... Proton pump inhibitors are used to: Relieve symptoms of acid reflux, or gastroesophageal reflux disease (GERD). This ...

  7. The German Aortic Valve Registry (GARY): in-hospital outcome

    OpenAIRE

    Hamm, Christian W.; Möllmann, Helge; Holzhey, David; Beckmann, Andreas; Veit, Christof; Figulla, Hans-Reiner; Cremer, J; Kuck, Karl-Heinz; Lange, Rüdiger; Zahn, Ralf; Sack, Stefan; Schuler, Gerhard; Walther, Thomas; Beyersdorf, Friedhelm; Böhm, Michael

    2013-01-01

    Background Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. Methods and results A total of 13 860 consecutive patients undergoing repair for aortic valve d...

  8. A Clinicopathological Study on Aortic Valves in Children

    Institute of Scientific and Technical Information of China (English)

    HUANG Ping; WANG Hongwei; ZHANG Zhenlu; HU Xiufen; LI Yanping; CHENG Peixuan; LIU Jianying

    2007-01-01

    In order to investigate the clinicopathological characteristics of aortic valve disease in children, all the native surgically excised aortic valves obtained between January 2003 and December 2005 were studied macroscopically and microscopically. The patients' medical records were reviewed and the clinical information was extracted. According to preoperative echocardiography, intraoperative assessment, and postoperative pathology, combined with clinical symptoms and signs, aortic valve diseases were divided into three categories: aortic stenosis (AS), aortic insufficiency (AI), and aortic stenosis with insufficiency (AS-AI). The etiology was determined according to the macroscopic, microscopic and clinical findings. The results showed that among 70 aortic valves, patient age ranged from 6 to 18 years, with a mean of 15.4 years, and there were 56 boys and 14 girts (male: female=4:1). Forty-four children only had pure aortic valve disease, and the other 26 children had aortic valve disease associated with other heart valve diseases. There were 5 cases of AS (7.14%), 60 cases of AI (85.71%) and 5 cases of AS-AI (7.14%). The causes were congenital aortic valve malformation (32 cases, 45.71%), rheumatic disease (28 cases, 40%), infective endocarditis (7 cases,10%), Marfan syndrome (2 cases, 2.86%), and undetermined (1 case, 1.43%). It was concluded that the common causes of aortic valve disease in order of frequency in children were congenital aortic valve malformation, rheumatic disease, infective endocarditis, and Marfan syndrome. AI was more common in children with aortic valve disease. Compared with adult patients, congenital bicuspid aortic valve in children was often AI. Histologically, the leaflets of congenital bicuspid aortic valve were mainly myxomatous, fibrosis and calcification less seen. AI was frequently found in rheumatic disease, mostly associated with other heart valve diseases. Macroscopic and microscopic examinations together with clinical

  9. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  10. Rapid prototyping in aortic surgery.

    Science.gov (United States)

    Bangeas, Petros; Voulalas, Grigorios; Ktenidis, Kiriakos

    2016-04-01

    3D printing provides the sequential addition of material layers and, thus, the opportunity to print parts and components made of different materials with variable mechanical and physical properties. It helps us create 3D anatomical models for the better planning of surgical procedures when needed, since it can reveal any complex anatomical feature. Images of abdominal aortic aneurysms received by computed tomographic angiography were converted into 3D images using a Google SketchUp free software and saved in stereolithography format. Using a 3D printer (Makerbot), a model made of polylactic acid material (thermoplastic filament) was printed. A 3D model of an abdominal aorta aneurysm was created in 138 min, while the model was a precise copy of the aorta visualized in the computed tomographic images. The total cost (including the initial cost of the printer) reached 1303.00 euros. 3D imaging and modelling using different materials can be very useful in cases when anatomical difficulties are recognized through the computed tomographic images and a tactile approach is demanded preoperatively. In this way, major complications during abdominal aorta aneurysm management can be predicted and prevented. Furthermore, the model can be used as a mould; the development of new, more biocompatible, less antigenic and individualized can become a challenge in the future. PMID:26803324

  11. Endovascular repair of abdominal aortic aneurysms.

    Science.gov (United States)

    Arnaoutakis, Dean J; Zammert, Martin; Karthikesalingam, Alan; Belkin, Michael

    2016-09-01

    Endovascular repair of abdominal aortic aneurysms is an important technique in the vascular surgeon's armamentarium, which has created a seismic shift in the management of aortic pathology over the past two decades. In comparison to traditional open repair, the endovascular approach is associated with significantly improved perioperative morbidity and mortality. The early survival benefit of endovascular abdominal aortic aneurysm repair is sustained up to 3 years postoperatively, but longer-term life expectancy remains poor regardless of operative modality. Nonetheless, most abdominal aortic aneurysms are now repaired using endovascular stent grafts. The technology is not perfect as several postoperative complications, namely endoleak, stent-graft migration, and graft limb thrombosis, can develop and therefore lifelong imaging surveillance is required. In addition, a postoperative inflammatory response has been documented after endovascular repair of aortic aneurysms; the clinical significance of this finding has yet to be determined. Subsequently, the safety and applicability of endovascular stent grafts are likely to improve and expand with the introduction of newer-generation devices and with the simplification of fenestrated systems. PMID:27650343

  12. Pump for Saturated Liquids

    Science.gov (United States)

    Elliott, D. G.

    1986-01-01

    Boiling liquids pumped by device based on proven components. Expanding saturated liquid in nozzle and diverting its phases along separate paths in liquid/vapor separator raises pressure of liquid. Liquid cooled in process. Pump makes it unnecessary to pressurize cryogenic liquids in order to pump them. Problems of introducing noncondensable pressurizing gas avoided.

  13. Challenging Friesian horse diseases : aortic rupture and megaesophagus

    NARCIS (Netherlands)

    Ploeg, M.

    2015-01-01

    Aortic rupture is quite rare in Warmblood horses and is best known as an acute and fatal rupture of the aortic root in older breeding stallions. It has now become clear that aortic rupture, which is diagnosed around an age of 4 years, is more frequent in the Friesian breed than in others. The high p

  14. Aneurysm sac enlargement after endovascular Abdominal Aortic Aneurysm repair

    NARCIS (Netherlands)

    Dingemans, Siem A; Jonker, Frederik H W; Moll, Frans L; van Herwaarden, JA

    2015-01-01

    The aim of this study is to give an overview of current knowledge regarding abdominal aortic aneurysm (AAA) growth after endovascular aortic aneurysm repair (EVAR) that could potentially lead to aortic rupture. A search on Pubmed was performed. A total of 705 articles were found after initial search

  15. Immediate post-operative responses to transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Egerod, Ingrid; Nielsen, Susanne; Lisby, Karen H.;

    2015-01-01

    Background:Conventional treatment for patients with severe symptomatic aortic stenosis is surgical aortic valve replacement (SAVR), but transcatheter aortic valve implantation (TAVI) has become a reliable alternative in high-risk patients.Aims:The aim of our study was to describe the post...

  16. Study of Coronary Artery Disease in Single Aortic Valvular Disease

    Institute of Scientific and Technical Information of China (English)

    张斌; 杨伟民; 占亚平

    2003-01-01

    Objectives To analyze the results of coronary angiographies (GAG) in patients with single aortic valvular heart disease; To study the relationship between aortic valve diseases and coronary artery disease (CAD). Methods 105 patients with single aortic valvular heart disease before surgery underwent angiography. The data of clinical characteristics and angiographies were analyzed. Results 51 patients had symptoms of angina pectoris among 105 patients with single aortic valvular heart disease. Seven of them were confirmed coronary artery disease by angiographies. Although the incidence of angina in aortic valve stenosis group was significantly higher than that in aortic valve regurgitation, the probability of combination of CAD in aortic valve stenosis group was similar to the later. However, the probability of combination of CAD in degenerative aortic valve group was significantly higher than the groups of rheumatic, congenitally bicuspid aortic valves, and other causes (p <0.01).Conclusions Angina pectoris is not sensitive for diagnosis of CAD in single aortic valve heart disease.The probability of combination of CAD in degenerative aortic valve disease is higher than that in aortic valve disease with other causes. Coronary angiography is strongly suggested for these patients.

  17. Breast milk - pumping and storing

    Science.gov (United States)

    ... a comfortable chair, sink, and electric pump. If pumping at work is going to be hard, build ... up your milk supply. Wash your hands before pumping. Collect breast milk when pumping. You can use: ...

  18. Determination of membrane tension during balloon distension of intestine.

    Science.gov (United States)

    Gregersen, H; Kassab, G S; Fung, Y C

    2004-09-01

    During the last decades, it has become increasingly common to make balloons distension in visceral organs in vivo. In particular this is true for studies of gastrointestinal motor function and biomechanics. Balloon distension is often used for assessment of small intestinal compliance and tension based on Laplace's law for cylindrical pressure pipes. This commonly used law is valid only when the balloon-distended intestine is cylindrical. Experimentally, it is seen that the diameter of the balloon-distended intestine is not a constant, but variable in the axial direction. Hence, it is necessary to improve Laplace's law for intestinal investigation. In this paper we develop the framework for determination of the tension distribution in circumferential and longitudinal direction during balloon distension. When the radii of curvature are measured from a photograph of the intestinal profile, then the membrane stress resultants can be computed everywhere in the intestine in contact with the balloon from the equations of equilibrium. The experimental data were obtained from small intestinal segments from five pigs and three guinea pigs. Papaverine was injected before the animals were sacrificed to relax the intestinal smooth muscle. The segments were immersed in a bath with calcium-free Krebs solution with dextran and EGTA. A balloon was distended in the lumen with pressures up to 15 cmH2O in the pigs and 10 cmH2O in the guinea pigs and radii were measured along the z-axis. The tension in circumferential direction had its maximum approximately 25% away from the middle of the balloon. The circumferential tension was 2-3 times higher than the longitudinal tension. In conclusion when we know the shape of the intestine, we can compute the circumferential and longitudinal components of tension. The large variation in tensions along the z axis must be considered when performing balloon distension studies in the gastrointestinal tract for studying physiological and

  19. Fenestrated endovascular aortic repair for juxtarenal abdominal aortic aneurysm

    Institute of Scientific and Technical Information of China (English)

    GUO Wei; ZHANG Hong-peng; LIU Xiao-ping; JIA Xin; XIONG Jiang; MA Xiao-hui

    2013-01-01

    Background Endovascular stent-graft with fenestration can improve proximal sealing in patients with juxtarenal abdominal aortic aneurysm (JAAA).The purpose of this study was to describe our primary experience and evaluate the safety and efficacy of fenestrated device for JAAA in high-risk patients.Methods Between March 2011 and May 2012,nine male patients (mean age,(79.6±8.6) years) with asymptomatic JAAAs underwent elective deployment of the Zenith fenestrated stent-grafts at a single institution.All patients were treated in the hybrid operating room under general anesthesia.Follow-up computed tomography angiography (CTA) was routinely performed before discharge,at 3,6,and 12 months and annually thereafter.Results Procedural success was achieved in all cases.Total sixteen small fenestrations,two large fenestrations and eight scallops were used.Intra-operative complications occurred in four patients,which included one proximal type Ⅰ endoleak,two type Ⅱ endoleaks,and one renal artery dissection.The mean hospital stay was (8.9±1.4) days,mean blood loss was (360.5±46.8) ml,and mean iodinated contrast volume was (230.6±58.3) ml.The mean follow-up time was (7.6±4.2) months.The visceral graft patency was 100% until now.One patient had an increase of serum creatinine of more than 30%,but did not require dialysis.No patients died,no stent fractured,and migration were diagnosed during the follow-up.Conclusions The early results of fenestrated device for high-risk patients with complex JAAAs are satisfactory.However,long-term fenestrated graft durability and branch vessel patency remain to be determined.

  20. Complexity Analysis of Balloon Drawing for Rooted Trees

    CERN Document Server

    Lin, Chun-Cheng; Poon, Sheung-Hung; Fan, Jia-Hao

    2010-01-01

    In a balloon drawing of a tree, all the children under the same parent are placed on the circumference of the circle centered at their parent, and the radius of the circle centered at each node along any path from the root reflects the number of descendants associated with the node. Among various styles of tree drawings reported in the literature, the balloon drawing enjoys a desirable feature of displaying tree structures in a rather balanced fashion. For each internal node in a balloon drawing, the ray from the node to each of its children divides the wedge accommodating the subtree rooted at the child into two sub-wedges. Depending on whether the two sub-wedge angles are required to be identical or not, a balloon drawing can further be divided into two types: even sub-wedge and uneven sub-wedge types. In the most general case, for any internal node in the tree there are two dimensions of freedom that affect the quality of a balloon drawing: (1) altering the order in which the children of the node appear in...

  1. Time-dependent strains and stresses in a pumpkin balloon

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    This paper presents a study of pumpkin-shaped superpressure balloons consisting of gores made from a thin polymeric film attached to high stiffness meridional tendons This type of design is being used for the NASA ULDB balloons The gore film shows considerable time-dependent stress relaxation whereas the behaviour of the tendons is essentially time-independent Upon inflation and pressurization the instantaneous i e linear-elastic strain and stress distributions in the film show significantly higher values in the meridional direction However over time and due to the biaxial visco-elastic stress relaxation of the the gore material the em hoop strains increase and the em meridional stresses decrease whereas the em remaining strain and stress components remain substantially unchanged These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission both in terms of the material performance and the overall stability of the shape of the balloon An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter 48 gore pumpkin balloon is presented The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature The results show good correlation with a numerical study using the ABAQUS finite-element package that includes a widely used model of

  2. Restenosis following balloon dilation of benign esophageal stenosis

    Institute of Scientific and Technical Information of China (English)

    Ying-Sheng Cheng; Ming-Hua Li; Ren-Jie Yang; Hui-Zhen Zhang; Zai-Xian Ding; Qi-Xin Zhuang; Zhi-Ming Jiang; Ke-Zhong Shang

    2003-01-01

    AIM: To elucidate the mechanism of restenosis following balloon dilation of benign esophageal stenosis.METHODS: A total of 49 rats with esophageal stenosis were induced in 70 rats using 5 ml of 50 % sodium hydroxide solution and the double-balloon method, and an esophageal restenosis (RS) model was developed by esophageal stenosis using dilation of a percutaneous transluminal coronary angioplasty (PTCA) balloon catheter. These 49 rats were divided into two groups: rats with benign esophageal stricture caused by chemical burn only (control group, n=21) and rats with their esophageal stricture treated with balloon catheter dilation (experimental group, n=28). Imaging analysis and immunohistochemistry were used for both quantitative and qualitative analyses of esophageal stenosis and RS formation in the rats, respectively.RESULTS: Cross-sectional areas and perimeters of the esophageal mucosa layer, muscle layer, and the entire esophageal layers increased significantly in the experimental group compared with the control group. Proliferating cell nuclear antigen (PCNA) was expressed on the 5th day after dilation, and was still present at 1 month. Fibronectin (FN)was expressed on the 1st day after dilation, and was still present at 1 month.CONCLUSION: Expression of PCNA and FN plays an important role in RS after balloon dilation of benign esophageal stenosis.

  3. Aerial Deployment and Inflation System for Mars Helium Balloons

    Science.gov (United States)

    Lachenmeler, Tim; Fairbrother, Debora; Shreves, Chris; Hall, Jeffery, L.; Kerzhanovich, Viktor V.; Pauken, Michael T.; Walsh, Gerald J.; White, Christopher V.

    2009-01-01

    A method is examined for safely deploying and inflating helium balloons for missions at Mars. The key for making it possible to deploy balloons that are light enough to be buoyant in the thin, Martian atmosphere is to mitigate the transient forces on the balloon that might tear it. A fully inflated Mars balloon has a diameter of 10 m, so it must be folded up for the trip to Mars, unfolded upon arrival, and then inflated with helium gas in the atmosphere. Safe entry into the Martian atmosphere requires the use of an aeroshell vehicle, which protects against severe heating and pressure loads associated with the hypersonic entry flight. Drag decelerates the aeroshell to supersonic speeds, then two parachutes deploy to slow the vehicle down to the needed safe speed of 25 to 35 m/s for balloon deployment. The parachute system descent dynamic pressure must be approximately 5 Pa or lower at an altitude of 4 km or more above the surface.

  4. Ballooning osteolysis in 71 failed total ankle arthroplasties.

    Science.gov (United States)

    Singh, Gurpal; Reichard, Theresa; Hameister, Rita; Awiszus, Friedemann; Schenk, Katja; Feuerstein, Bernd; Roessner, Albert; Lohmann, Christoph

    2016-08-01

    Background and purpose - Aseptic loosening is a major cause of failure in total ankle arthroplasty (TAA). In contrast to other total joint replacements, large periarticular cysts (ballooning osteolysis) have frequently been observed in this context. We investigated periprosthetic tissue responses in failed TAA, and performed an element analysis of retrieved tissues in failed TAA. Patients and methods - The study cohort consisted of 71 patients undergoing revision surgery for failed TAA, all with hydroxyapatite-coated implants. In addition, 5 patients undergoing primary TAA served as a control group. Radiologically, patients were classified into those with ballooning osteolysis and those without, according to defined criteria. Histomorphometric, immunohistochemical, and elemental analysis of tissues was performed. Von Kossa staining and digital microscopy was performed on all tissue samples. Results - Patients without ballooning osteolysis showed a generally higher expression of lymphocytes, and CD3+, CD11c+, CD20+, and CD68+ cells in a perivascular distribution, compared to diffuse expression. The odds of having ballooning osteolysis was 300 times higher in patients with calcium content >0.5 mg/g in periprosthetic tissue than in patients with calcium content ≤0.5 mg/g (p < 0.001). Interpretation - There have been very few studies investigating the pathomechanisms of failed TAA and the cause-effect nature of ballooning osteolysis in this context. Our data suggest that the hydroxyapatite coating of the implant may be a contributory factor.

  5. Development of Ultra-Thin Polyethylene Balloons for High Altitude Research upto Mesosphere

    Science.gov (United States)

    Kumar, B. Suneel; Nagendra, N.; Ojha, D. K.; Peter, G. Stalin; Vasudevan, R.; Anand, D.; Kulkarni, P. M.; Reddy, V. Anmi; Rao, T. V.; Sreenivasan, S.

    Ever since its inception four decades back, Balloon Facility of Tata Institute of Fundamental Research (TIFR), Hyderabad has been functioning with the needs of its user scientists at its focus. During the early nineties, when the X-ray astronomy group at TIFR expressed the need for balloons capable of carrying the X-ray telescopes to altitudes up to 42 km, the balloon group initiated research and development work on indigenous balloon grade films in various thickness not only for the main experiment but also in parallel, took up the development of thin films in thickness range 5 to 6 μm for fabrication of sounding balloons required for probing the stratosphere up to 42 km as the regular 2000-gram rubber balloon ascents could not reach altitudes higher than 38 km. By the year 1999, total indigenization of sounding balloon manufacture was accomplished. The work on balloon grade ultra-thin polyethylene film in thickness range 2.8 to 3.8 μm for fabrication of balloons capable of penetrating mesosphere to meet the needs of user scientists working in the area of atmospheric dynamics commenced in 2011. Pursuant to the successful trials with 61,000-m3 balloon made of 3.8-μm Antrix film reaching stratopause (48 km) for the first time in the history of balloon facility in the year 2012, fine tuning of launch parameters like percentage free lift was carried out to take the same volume balloons to higher mesospheric altitudes. Three successful flights with a total suspended load of 10 kg using 61,000-m3 balloons were carried out in the month of January 2014 and all the three balloons crossed into the mesosphere reaching altitudes of over 51 km. All the balloons flown so far are closed system with no escape ducts. Balloon fabrication, development of launch hardware, flight control instruments and launch technique for these mesospheric balloon flights are discussed in this paper.

  6. The future of aortic surgery in Europe

    DEFF Research Database (Denmark)

    Czerny, Martin; Bachet, Jean; Bavaria, Joseph;

    2012-01-01

    At least every ten years, each specialty should reflect upon its past, its present and its future, in order to be able to reconfirm the direction in which it is headed, to adopt suggestions from inside and outside and, consequently, to improve. As such, the aim of this manuscript is to provide th...... in Europe, namely the Vascular Domain of the European Association of Cardio-Thoracic Surgery (EACTS)....... the interested reader with an overview of how aortic surgery and (perhaps more accurately) aortic medicine has evolved in Europe, and its present standing; also to provide a glimpse into the future, trying to disseminate the thoughts of a group of people actively involved in the development of aortic medicine...

  7. ED 02-1 ACUTE AORTIC SYNDROME.

    Science.gov (United States)

    Song, Jae-Kwan

    2016-09-01

    The successful clinical introduction of various non-invasive imaging modalities has contributed to the establishment of 'acute aortic syndrome', a relatively new clinical syndrome incorporating several disease entities with similar clinical features (at the time of clinical presentation). Aortic dissection (AD) with intimal flap and two aortic channels (true and false lumens) is the most important disease entity in acute aortic syndrome. Clinical characteristics of AD have been established, with standardized treatment strategies depending on the affected site of the aorta. For the past several decades, variant forms of classic AD, including aortic intramural hematoma (IMH) and incomplete dissection, have been increasingly diagnosed in routine clinical practice worldwide, and imaging findings characteristic of these variant forms have been established for their differential diagnosis. As imaging findings, rather than clinical features, are critical for the differential diagnosis of acute aortic syndrome, careful interpretation of imaging results is necessary for accurate diagnosis and better clinical decision-making, thus improving patient outcomes. IMH is probably the most important variant form of classic AD and has been the source of intense controversy regarding its pathogenesis and optimal treatment options. Clinical reports regarding outcomes of patients with IMH from different centers have shown conflicting results and risk stratification based on imaging findings remains a challenging clinical issue.Intimal tears can have a very wide spectrum. For example, a stellate or linear intimal tear can involve the exposure of the underlying aortic media or adventitial layers but without the progression and separation of the medial layers, resulting in extensive undermining of the intimal layers. This incomplete dissection, characterized by an intimal tear without an intimal flap or hematoma, was reported to be present in 9 of 181 (5%) consecutive patients with

  8. Acute Aortic Dissection Extending Into the Lung.

    Science.gov (United States)

    Makdisi, George; Said, Sameh M; Schaff, Hartzell V

    2015-07-01

    The radiologic manifestations of ruptured acute aortic dissection, Stanford type A aortic dissection, DeBakey type 1 can present in different radiographic scenarios with devastating outcomes. Here, we present a rare case of a 70-year-old man who presented to the emergency department with chest pain radiating to the back. A chest computed tomography scan showed a Stanford type A, DeBakey type 1, acute aortic dissection ruptured into the aortopulmonary window and stenosing the pulmonary trunk, both main pulmonary arteries, and dissecting the bronchovascular sheaths and flow into the pulmonary interstitium, causing pulmonary interstitial hemorrhage. The patient underwent emergent ascending aorta replacement with hemiarch replacement with circulatory arrest. The postoperative course was unremarkable. PMID:26140779

  9. Temporary extracorporeal bypass modalities during aortic surgery.

    Science.gov (United States)

    Bassin, Levi; Bell, David

    2016-09-01

    The key to aortic surgery is protection of the brain, heart, spinal cord, and viscera. For operations involving the aortic arch, the focus is on cerebral protection, while for pathology involving the descending thoracic aorta, the focus is on spinal protection. Optimal cerebral and spinal protection requires an extensive knowledge of the operative steps and an understanding of the cardiopulmonary bypass modalities that are possible. A bloodless field is required when operating on the aorta. As a result, periods of ischemia to the central nervous system and end-organ viscera are often unavoidable. The main techniques to mitigate ischemia include hypothermia and selective perfusion of the ischemic organ in question. This chapter will first briefly review bypass modalities and then describe how they can be used for various aortic scenarios. PMID:27650344

  10. Transcatheter CoreValve valve-in-valve implantation in a stentless porcine aortic valve for severe aortic regurgitation

    OpenAIRE

    Yong, Celina M; Buchbinder, Maurice; Giacomini, John C

    2014-01-01

    Key Clinical Message We describe the first valve-in-valve Corevalve transcatheter aortic valve replacement in the St. Jude Toronto stentless porcine aortic valve in the United States, which enabled this 59-year-old patient with a history of bacterial endocarditis and aortic regurgitation to avoid heart transplant with complete resolution of his severe left ventricular dysfunction.

  11. Diagnostic imaging of acute aortic dissection

    International Nuclear Information System (INIS)

    One hundred and nineteen patients with aortic dissection who underwent diagnostic imaging were reviewed and angiographic findings as well as those of CT were analysed. Thirty eight cases (43.1%) had non-contrast opacified false lumen, the type of which we call 'thrombosed type aortic dissection'. A comparative study of the thrombosed type with the patent type of false lumens was made particularly from the stand point of the characteristic diagnostic imagings (CT and angiography). At the same time, the pitfalls of these imagings in thrombosed type aortic dissection were studied. At the onset the average age of thrombosed type was 62.3 years old, while that of the patent type was 57.3. A statistical significance between the two groups was p<0.05. Thrombosed type in all cases was caused by atherosclerosis, whereas patent type was caused by the Marfan's syndrome in 11 cases. Other clinical findings, such as initial symptoms and blood pressure revealed no significant differences between the two groups. Pre-contrast CT in acute thrombosed type aortic dissection showed 'hyperdense crescent sign' in 89.4%. However, in 3 cases with thrombosed type in which the pre-contrast CT showed 'hyperdense crescent sign' contrast-enhanced CT detected no clear evidence of aortic dissection in the same site. This was due to obscurity induced by contrast medium. Angiographic findings of thrombosed type were classified into 3 groups: normal type, stenosed true lumen type and ulcer-like projection type. The incidence of normal type was estimated to be 48.4%, whereas stenosed true lumen type was 24.2% and ulcer-like projection was 27.7%. The present study concluded that thrombosed type is not rare in acute aortic dissection and contrast-enhanced CT as well as pre-contrast CT, is of great value in diagnosing thrombosed type. 'Hyperdense crescent sign' in pre-contrast CT is characteristic of intramural hematoma. (author)

  12. Anesthesia Approach in Endovascular Aortic Reconstruction

    Directory of Open Access Journals (Sweden)

    Ayşin Alagöl

    2013-03-01

    Full Text Available Introduction: We have analyzed our initial results of our anesthesia techniques in our new-onset endovascular aortic reconstruction cases.Patients and Methods: The perioperative data of 15 elective and emergent endovascular aortic reconstruction cases that were operated in 2010-2011 were collected in a database. The choice of anesthesia was made by the risk factors, surgical team’s preferences, type and location of the aortic pathology and by the predicted operation duration. The data of local and general anesthesia cases were compared.Results: Thirteen (86.7% cases were male and 2 (13.3% female. Eleven patients were in ASA Class III. The demographic parameters, ASA classifications, concurrent diseases were similar in both groups. Thirteen (86.7% cases had infrarenal abdominal aortic aneurysm and 2 (13.3% had Type III aortic dissection. The diastolic arterial pressures were lower in general anesthesia group in 20th and 40th minutes’ measurements just like the mean arterial pressure measurements at the 40th, 100th minutes and during the deployment of the graft. Postoperative mortality occurred in 3 (20.0% patients and they all had general anesthesia and they were operated on emergency basis. Postoperative morbidity occurred in four patients that had general anesthesia (acute renal failure, multi-organ failure and pneumonia. The other patient had atrial fibrillation on the 1st postoperative day and was converted to sinus rhythm with amiodarone infusion.Conclusion: Edovascular aortic reconstruction procedures can safely be performed with both general and local anesthesia less invasively compared to open surgery. General anesthesia may be preferred for the better hemodynamic control.

  13. High-n ballooning modes in highly elongated tokamaks

    International Nuclear Information System (INIS)

    An analytic study of stability against high-n ballooning modes is highly elongated axisymmetric plasmas is presented and compared with computational results. - From the equation for the marginal pressure gradient, it is found that local shear has an important effect on the stability of elongated plasmas, and that stability deteriorates through high elongation since the stabilizing effects of field line bending and local shear are reduced. The net contribution of the local shear to stability decreases with elongation for strong ballooning modes (eigenfunctions strongly localized near the outer edge of the toroidal flux surfaces) but increases for interchange modes (eigenfunctions more uniform along the flux surfaces). - The computational study of high-n ballooning modes in a highly elongated plasma reveals that lowering the aspect ratio and broadening the pressure profile enhance the marginal beta for βsub(p) less than unity but severely reduce the marginal beta for βsub(p) larger than unity. (author)

  14. Extrusion process optimization for toughness in balloon films

    Science.gov (United States)

    Cantor, K. M.; Harrison, I. R.

    1993-01-01

    An experimental optimization process for blown film extrusion is described and examined in terms of the effects of the technique on the toughness of balloon films. The optimization technique by Cantor (1990) is employed which involves the identification of key process variables including screw speed, nip speed, bubble diameter, and frost-line height for analysis to optimize the merit function. The procedure is employed in the extrusion of a low-density polyethylene polymer, and the resulting optimized materials are toughness- and puncture-tested. Balloon toughness is optimized in the analytical relationship, and the process parameters are modified to attain optimal toughness. The film produced is shown to have an average toughness of 24.5 MPa which is a good value for this key property of balloon materials for high-altitude flights.

  15. Tokamak resistive magnetohydrodynamic ballooning instability in the negative shear regime

    Institute of Scientific and Technical Information of China (English)

    Shi Bing-Ren; Lin Jian-Long; Li Ji-Quan

    2007-01-01

    Improved confinement of tokamak plasma with central negative shear is checked against the resistive ballooning mode. In the negative shear regime, the plasma is always unstable for purely growing resistive ballooning mode. For a simplest tokamak equilibrium model, the s-α model, characteristics of this kind of instability are fully clarified by numerically solving the high n resistive magnetohydrodynamic ballooning eigen-equation. Dependences of the growth rate on the resistivity, the absolute shear value, the pressure gradient are scanned in detail. It is found that the growth rate is a monotonically increasing function of a while it is not sensitive to the changes of the shear s, the initial phase θ0 and the resistivity parameter εR.

  16. Ideal MHD Ballooning modes, shear flow and the stable continuum

    CERN Document Server

    Taylor, J B

    2012-01-01

    There is a well established theory of Ballooning modes in a toroidal plasma. The cornerstone of this is a local eigenvalue lambda on each magnetic surface - which also depends on the ballooning phase angle k. In stationary plasmas lambda(k) is required only near its maximum, but in rotating plasmas its average over k is required. Unfortunately in many case lambda(k) does not exist for some range of k, because the spectrum there contains only a stable continuum. This limits the application of the theory, and raises the important question of whether this "stable interval" gives rise to significant damping. This question is re-examined using a new, simplified, model - which leads to the conclusion that there is no appreciable damping at small shear flow. In particular, therefore, a small shear flow should not affect Ballooning mode stability boundaries.

  17. Ideal ballooning modes, shear flow and the stable continuum

    Science.gov (United States)

    Taylor, J. B.

    2012-11-01

    There is a well-established theory of ballooning modes in a toroidal plasma. The cornerstone of this is a local eigenvalue λ on each magnetic surface—which also depends on the ballooning phase angle k. In stationary plasmas, λ(k) is required only near its maximum, but in rotating plasmas its average over k is required. Unfortunately in many cases λ(k) does not exist for some range of k, because the spectrum there contains only a stable continuum. This limits the application of the theory, and raises the important question of whether this ‘stable interval’ gives rise to significant damping. This question is re-examined using a new, simplified, model—which leads to the conclusion that there is no appreciable damping at small shear flow. In particular, therefore, a small shear flow should not affect ballooning mode stability boundaries.

  18. Drug-Coated Balloons for Infrainguinal Peripheral Artery Disease.

    Science.gov (United States)

    Sethi, Sanjum S; Lee, Michael S

    2016-07-01

    Revascularization of infrainguinal peripheral artery disease has traditionally been accomplished via percutaneous transluminal angioplasty. However, long-term results have been hampered by high rates of restenosis. Along with the advent of stents, paclitaxel-coated balloons are an emerging therapeutic option for the invasive management of infrainguinal peripheral artery disease. Paclitaxel has been successful in inhibiting neointimal hyperplasia, the main mechanism for in-stent restenosis. Technological advances have facilitated the development of paclitaxel-coated balloons, which show promise in early trials for femoropopliteal stenosis relative to uncoated balloons. For infrapopliteal stenoses, the data remain scant and conflicted. Therefore, large-scale randomized clinical trials with long-term follow-up evaluating safety and effectiveness between various strategies need to be performed to determine the optimal invasive management strategy for infrainguinal peripheral artery disease. PMID:27342205

  19. Dynamic electromechanical instability of a dielectric elastomer balloon

    Science.gov (United States)

    Chen, Feifei; Zhu, Jian; Wang, Michael Yu

    2015-11-01

    Electromechanical instability, a significant phenomenon in dielectric elastomers, has been well studied in the literature. However, most previous work was based on the assumption that dielectric elastomers undergo quasi-static deformation. This letter investigates the dynamic electromechanical instability of a dielectric elastomer balloon which renders four types of oscillation subject to a parametric combination of DC and AC voltages. The simulated oscillations show that dynamic electromechanical instability occurs within quite a large range of excitation frequency, in the form of snap-through or snap-back, when the DC and AC voltages reach critical values. The balloon is at its most susceptible to dynamic electromechanical instability when the superharmonic, harmonic or subharmonic resonance is excited. Taking all excitation parameters into account, this letter analyzes the global critical condition which triggers the dynamic electromechanical instability of the balloon.

  20. Idiopathic thoracic aortic aneurysm at pediatric age.

    Science.gov (United States)

    Marín-Manzano, E; González-de-Olano, D; Haurie-Girelli, J; Herráiz-Sarachaga, J I; Bermúdez-Cañete, R; Tamariz-Martel, A; Cuesta-Gimeno, C; Pérez-de-León, J

    2009-03-01

    A 6-year-old-boy presented with epigastric pain and vomiting over 1 year. Chest X-ray and esophagogastric transit showed a mediastinal mass. A chest computerized tomography angiogram demonstrated a descending thoracic aortic aneurysm. Analytical determinations carried out were all negative. The aneurysm was surgically repaired using a Dacron patch. The anatomopathological study described atherosclerotic lesions with calcifications, compatible with an atherosclerotic aneurysm wall. Aneurysms are uncommon in the pediatric population. Usually, no pathogenesis can be determined, and thus, such cases are grouped as idiopathic. Direct repair with or without patch is a therapeutic alternative in pediatric aneurysms and can allow the growth of the aortic circumference.

  1. Chylous complications after abdominal aortic surgery.

    Science.gov (United States)

    Haug, E S; Saether, O D; Odegaard, A; Johnsen, G; Myhre, H O

    1998-12-01

    Two patients developed chylous complications following abdominal aortic aneurysm repair. One patient had chylous ascitis and was successfully treated by a peritoneo-caval shunt. The other patient developed a lymph cyst, which gradually resorbed after puncture. Chylous complications following aortic surgery are rare. Patients in bad a general condition should be treated by initial paracentesis and total parenteral nutrition, supplemented by medium-chain triglyceride and low-fat diet. If no improvement is observed on this regimen, the next step should be implementation of a peritoneo-venous shunt, whereas direct ligation of the leak should be reserved for those who are not responding to this treatment. PMID:10204656

  2. Infective endocarditis following transcatheter aortic valve replacement-

    DEFF Research Database (Denmark)

    Loh, Poay Huan; Bundgaard, Henning; S�ndergaard, Lars

    2013-01-01

    Transcatheter aortic valve replacement (TAVR) can improve the symptoms and prognosis of patients with severe aortic stenosis who, due to a high expected operative risk, would not have otherwise been treated surgically. If these patients develop prosthetic valve endocarditis, their presentations may...... be atypical causing a delay in the diagnosis and treatment. The management is also complicated by their comorbidities, and surgical treatment may not be feasible leading to a significant morbidity and mortality. We describe a case of an 85-year-old man with TAVI prosthetic valve endocarditis successfully...

  3. Contemporary management of blunt aortic trauma.

    Science.gov (United States)

    Dubose, J J; Azizzadeh, A; Estrera, A L; Safi, H J

    2015-10-01

    Blunt thoracic aortic injury (BTAI) remains a common cause of death following blunt mechanisms of trauma. Among patients who survive to reach hospital care, significant advances in diagnosis and treatment afford previously unattainable survival. The Society for Vascular Surgery (SVS) guidelines provide current best-evidence suggestions for treatment of BTAI. However, several key areas of controversy regarding optimal BTAI care remain. These include the refinement of selection criteria, timing for treatment and the need for long-term follow-up data. In addition, the advent of the Aortic Trauma Foundation (ATF) represents an important development in collaborative research in this field. PMID:25868973

  4. Aortic valve replacement in octogenarians

    Directory of Open Access Journals (Sweden)

    Dark John H

    2007-07-01

    Full Text Available Abstract Background and Aims As our population ages and life expectancy increases the number of people aged over 80 and more referred for cardiac surgery is growing. This study sought to identify the outcome of aortic valve replacement (AVR in octogenarians. Methods 68 patients aged 80 years or more underwent AVR at the Freeman Hospital, between April 2001 and April 2004. A retrospective review of the notes and outcomes from the patients' GP and the NHS strategic tracking service was performed. 54% (37 underwent isolated AVR whilst 46% (31 underwent combined AVR and CABG. Results Follow up was 100% complete. The mean age was 83.1 ± s.d. 2.9 years, a mean gradient of 83 ± s.d. 31 mmHg and mean AVA of 0.56 cm2. The mean additive EuroSCORE was 8.6 ± s.d. 1.2, the logistic EuroSCORE mean 12.0 ± s.d. 5.9. In hospital 30 day mortality was 13 %. Survival was 80% at 1 year and 78% at 2 years. Median follow up was for 712 days. Stepwise logistic regression identified chronic obstructive airways disease as an independent predictor of mortality (p Conclusion Our study demonstrates that the operative mortality for AVR in the over eighties is good, whilst the mid to long term outcome is excellent There is a very low attrition rate with those undergoing the procedure living as long than their age matched population. This study confirms AVR is a safe, acceptable treatment for octogenarians with excellent mid term outcomes.

  5. Experience with the Sarns centrifugal pump in postcardiotomy ventricular failure.

    Science.gov (United States)

    Curtis, J J; Walls, J T; Schmaltz, R; Boley, T M; Nawarawong, W; Landreneau, R J

    1992-09-01

    The reported clinical use of the Sarns centrifugal pump (Sarns, Inc./3M, Ann Arbor, Mich.) as a cardiac assist device for postcardiotomy ventricular failure is limited. During a 25-month period ending November 1988, we used 40 Sarns centrifugal pumps as univentricular or biventricular cardiac assist devices in 27 patients who could not be weaned from cardiopulmonary bypass despite maximal pharmacologic and intraaortic balloon support. Eighteen men and nine women with a mean age of 60.4 years (28 to 83) required assistance. Left ventricular assist alone was used in 12 patients, right ventricular assist in 2, and biventricular assist in 13. The duration of assist ranged from 2 to 434 hours (median 45). Centrifugal assist was successful in weaning 100% of the patients. Ten of 27 patients (37%) improved hemodynamically, allowing removal of the device(s), and 5 of 27 (18.5%) survived hospitalization. Survival of patients requiring left ventricular assist only was 33.3% (4/12). Complications were common and included renal failure, hemorrhage, coagulopathy, ventricular arrhythmias, sepsis, cerebrovascular accident, and wound infection. During 3560 centrifugal pump hours, no pump thrombosis was observed. The Sarns centrifugal pump is an effective assist device when used to salvage patients who otherwise cannot be weaned from cardiopulmonary bypass. Statistical analysis of preoperative patient characteristics, operative risk factors, and postoperative complications failed to predict which patients would be weaned from cardiac assist or which would survive.

  6. To sail the skies of Mars - Scientific ballooning on the red planet

    Science.gov (United States)

    Gaidos, Eric J.; Burke, James D.

    1988-01-01

    Balloons represent a novel approach to exploring the surface of Mars. One promising aerostat system incorporates a solar-powered balloon as a means of generating diurnally varying lift and so can 'hop' across the surface, obtaining detailed information at a large number of sites. Two important areas of research and testing are underway on solar balloon technology and balloon payload design. The solar balloon concept has been demonstrated on earth, but more work is needed on a 'flyable' version for Mars. Particular attention must be paid to radiation heat transfer and aerodynamic effects. A special 'snake' payload concept has been demonstrated that allows for balloon system traverses of the surface and provides a usable instrument platform. A balloon system of this type could obtain unique surface imaging and physical and chemical data. The flight of the balloon also provides in situ atmospheric boundary-layer and circulation measurements.

  7. Membranous duodenal stenosis: Initial experience with balloon dilatation in four children

    International Nuclear Information System (INIS)

    Introduction: We present a novel approach to the treatment of membranous duodenal stenosis (MDS). To our knowledge this is the first paper to describe balloon dilatation for this entity. Material and methods: Four children, 2 boys and 2 girls, aged between 8 and 28 days, underwent duodenal balloon dilatation. Balloon dilatation was performed under general anaesthesia using standard angiography balloons per os. Balloon diameters ranged from 6 to 14 mm. Results: All balloon dilatations were successful. None of the procedures showed procedural or post-procedural complications. None of the patients subsequently required surgical intervention. To date all children are doing well. Discussion: The initial experience with balloon dilation of MDS showed a 100% success rate, without procedural or post-procedural complications. The results obtained in this small group of patients suggest that the use of balloon dilatation in cases of MDS may be a safe technique that can be readily performed by an experienced interventional radiologist

  8. Balloon vetebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures

    NARCIS (Netherlands)

    Verlaan, JJ; van Helden, WH; Oner, FC; Verbout, AJ; Dhert, WJA

    2002-01-01

    Study Design. A human cadaveric model was used to evaluate balloon vertebroplasty in traumatic vertebral fractures. Objectives. To assess the feasibility and safety of balloon vertebroplasty followed by calcium phosphate cement augmentation to prevent recurrent kyphosis. Summary of Background Data.

  9. Treatment of infrarenal abdominal aortic dissection concomitant with an aneurysm

    Institute of Scientific and Technical Information of China (English)

    WANG Li-xin; ZHU Ting; FU Wei-guo; WANG Yu-qi; XI Xun; GUO Da-qiao; CHEN Bin; JIANG Jun-hao; YANG Ju; SHI Zhen-yu

    2007-01-01

    @@ Aortic dissection occurs when layers of the aortic walls are separated by the blood flow through an intimal tear. Dissection of the aorta most frequently originates in the ascending aorta (70%), followed by the descending aorta (22%), the aortic arch (7%) and the abdominal aorta (1/%).1 The dissection limited to the abdominal aorta is rare.2 An isolated abdominal aortic dissection (IAAD) concomitant with an abdominal aortic aneurysm (AAA) is uncommon. We present here one patient with IAAD and AAA treated by endovascular therapy.

  10. Infected abdominal aortic aneurysm due to Morganella morganii: CT findings.

    Science.gov (United States)

    Kwon, Oh Young; Lee, Jong Seok; Choi, Han Sung; Hong, Hoon Pyo; Ko, Young Gwan

    2011-02-01

    An infected aortic aneurysm, or mycotic aneurysm, is a rare arterial dilatation due to destruction of the infected vessel wall. Common pathogens resulting in an infected aortic aneurysm are Salmonella and Clostridium species, as well as Staphylococcus aureus; Morganella morganii, on the other hand, is very rare. An infected abdominal aortic aneurysm has tendencies to grow rapidly and to rupture. The mortality rate is high in patients undergoing emergent surgical intervention. We report the case of a 65-year-old man who presented with an infected abdominal aortic aneurysm caused by M. morganii. A high index of suspicion and imaging tests are necessary in order to diagnose an infected aortic aneurysm.

  11. Diffuse Supravalvular Aortic Stenosis: Surgical Repair in Adulthood

    Directory of Open Access Journals (Sweden)

    Giovanni Ferlan

    2009-01-01

    Full Text Available We present the case of a 54-year-old woman in which a diffuse congenital supravalvular aortic stenosis (SVAS was associated with a severe aortic valve incompetence and heavy calcification of the aortic annulus. Repair consisted in resection of the ascending aorta, patch augmentation of the hypoplastic aortic root and annulus, placement of a 20 mm Dacron tubular graft (Vascutek, Renfrewshire, UK and aortic valve replacement with a mechanical prosthesis (Sorin, Turin, Italy. Follow-up echocardiography demonstrated normal prosthetic valve function and a postoperative three-dimensional computed tomographic scan showed a normal shape of the reconstructed ascending aorta.

  12. Near Space Lab-Rat Experimentation using Stratospheric Balloon

    Science.gov (United States)

    Buduru, Suneel Kumar; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Trivedi, Dharmesh; Devarajan, Anand; Pandit Manikrao Kulkarni, MR..; Ojha, Devendra; Korra, Sakram; Neerudu, Nagendra; Seng, Lim; Godi, Stalin Peter

    2016-07-01

    First ever balloon borne lab-rat experiment up to near space stratospheric altitude levels carried out at TIFR Balloon Facility, Hydeabad using zero pressure balloons for the purpose of validating the life support system. A series of two balloon experiments conducted under joint collaboration with IN.Genius, Singapore in the year 2015. In these experiments, three lab-rats sent to stratosphere in a pressurized capsule designed to reach an altitude of 30 km by keeping constant pressure, temperature and maintained at a precise rate of oxygen supply inside the capsule. The first experiment conducted on 1 ^{st} February, 2015 with a total suspended weight of 225 kg. During the balloon ascent stage at 18 km altitude, sensors inside the capsule reported drastic drop in internal pressure while oxygen and temperatures maintained at correct levels resulted in premature fligt termination at 20.1 km. All the three lab-rats recovered without life due to the collapse of their lungs caused by the depressurization inside the capsule. The second experiment conducted on 14th March, 2015 using a newly developed capsule with rectification of depressurization fault by using improved sealing gaskets and hermitically sealed connectors for sending lab-rats again to stratosphere comprising a total suspended load of 122.3 kg. The balloon flight was terminated after reaching 29.5 km in 110 minutes and succesfully recovered all the three lab-rats alive. This paper focuses on lessons learnt of the development of the life support system as an integral pressurized vessel, flight control instrumentation, flight simulation tests using thermo-vaccum chamber with pre-flight operations.

  13. Balloon-Borne Infrasound Detection of Energetic Bolide Events

    Science.gov (United States)

    Young, Eliot F.; Ballard, Courtney; Klein, Viliam; Bowman, Daniel; Boslough, Mark

    2016-10-01

    Infrasound is usually defined as sound waves below 20 Hz, the nominal limit of human hearing. Infrasound waves propagate over vast distances through the Earth's atmosphere: the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization) has 48 installed infrasound-sensing stations around the world to detect nuclear detonations and other disturbances. In February 2013, several CTBTO infrasound stations detected infrasound signals from a large bolide that exploded over Chelyabinsk, Russia. Some stations recorded signals that had circumnavigated the Earth, over a day after the original event. The goal of this project is to improve upon the sensitivity of the CTBTO network by putting microphones on small, long-duration super-pressure balloons, with the overarching goal of studying the small end of the NEO population by using the Earth's atmosphere as a witness plate.A balloon-borne infrasound sensor is expected to have two advantages over ground-based stations: a lack of wind noise and a concentration of infrasound energy in the "stratospheric duct" between roughly 5 - 50 km altitude. To test these advantages, we have built a small balloon payload with five calibrated microphones. We plan to fly this payload on a NASA high-altitude balloon from Ft Sumner, NM in August 2016. We have arranged for three large explosions to take place in Socorro, NM while the balloon is aloft to assess the sensitivity of balloon-borne vs. ground-based infrasound sensors. We will report on the results from this test flight and the prospects for detecting/characterizing small bolides in the stratosphere.

  14. BETTII: The Balloon Experimental Twin Telescope for Infrared Interferometry

    Science.gov (United States)

    Rinehart, Stephen

    2011-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding the universe. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scale on which mid-to far-infrared emission arises. We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII),8oeight-meter Michelson interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks io young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers.

  15. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

    Science.gov (United States)

    Rinehart, Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. BETTII uses a double-Fourier Michelson interferometer to simultaneously obtain spatial and spectral information on science targets; the long baseline provides subarcsecond angular resolution, a capability unmatched by other far-infrared facilities. Here, we present key aspects of the overall design of the mission and provide an overview of the current status of the project. We also discuss briefly the implications of this experiment for future space-based far-infrared interferometers.

  16. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  17. Cosmic ray abundance measurements with the CAKE balloon experiment

    CERN Document Server

    Cecchini, S; Giacomelli, G; Manzoor, S; Medinaceli, E; Patrizii, L; Togo, V

    2005-01-01

    We present the results from the CAKE (Cosmic Abundance below Knee Energy) balloon experiment which uses nuclear track detectors. The final experiment goal is the determination of the charge spectrum of CR nuclei with Z $>$ 30 in the primary cosmic radiation. The detector, which has a geometric acceptance of $\\sim$ 1.7 m$^2$sr, was exposed in a trans-mediterranean stratospheric balloon flight. Calibrations of the detectors used (CR39 and Lexan), scanning strategies and algorithms for tracking particles in an automatic mode are presented. The present status of the results is discussed

  18. Testing in a stratospheric balloon of a semiconductor detector altimeter

    International Nuclear Information System (INIS)

    An altimeter containing a semiconductor detector has been operated on flight. We have used a stratospheric balloon launched from AIRE-SUR-ADOUR with the C.N.E.S. collaboration. During this assay two apparatus have been used. The first allowed to follow the balloon during its ascension and descent, the second to follow its evolution at its maximum altitude. Informations transmitted by radio and recorded on Magnetophon, have been studied after the flight. Results are identical with these given by the barometer used by the C.N.E.S. in this essay. (authors)

  19. Balloon-Borne System Would Aim Instrument Toward Sun

    Science.gov (United States)

    Polites, M. E.

    1992-01-01

    Proposed system including digital control computer, control sensors, and control actuators aims telescope or other balloon-borne instrument toward Sun. Pointing system and instrument flown on gondola, suspended from balloon. System includes reaction wheel, which applies azimuthal control torques to gondola, and torque motor to apply low-frequency azimuthal torques between gondola and cable. Three single-axis rate gyroscopes measure yaw, pitch, and roll. Inclinometer measures roll angle. Two-axis Sun sensor measures deviation, in yaw and pitch, of attitude of instrument from line to apparent center of Sun. System provides initial coarse pointing, then maintains fine pointing.

  20. Polymer blends for LDB applications. [Long Duration Ballooning

    Science.gov (United States)

    Lichkus, Andrew M.; Harrison, Ian R.

    1991-01-01

    A series of LCP/PE blends have been studied to determine the potential of such systems to produce a high modulus balloon film material which retains the balloon fabrication and low temperature flight advantages of the current PE films. Blown films of blends of 5 and 15 percent LCP in PE have been produced which show a 28 percent enhancement in modulus over the neat PE matrix. These results are substantially lower than anticipated and are explained in terms of the LCP reinforcement aspect ratio and fibril diameter.

  1. Congenital quadricuspid aortic valve: analysis of 11 surgical cases

    Institute of Scientific and Technical Information of China (English)

    TANG Yang-feng; XU Ji-bin; HAN Lin; LU Fang-lin; LANG Xi-long; SONG Zhi-gang; XU Zhi-yun

    2011-01-01

    Background Congenital quadricuspid aortic valve is rarely seen during aortic valve replacement (AVR).The diagnosis and treatment of the disease were reported in 11 cases.Methods Eleven patients (nine men and two women,mean age 33.4 years) with quadricuspid aortic valve were retrospectively evaluated.Medical records,echocardiograms and surgical treatment were reviewed.Results In accordance with the Hurwitz and Roberts classification,the patients were classified as type A (n=2),type B (n=7),type F (n=1) and type G (n=1).Three patients were associated with other heart diseases,including infective endocarditis and mitral prolaps,left superior vena cava,aortic aneurysm.All had aortic regurgitation (AR) except two with aortic stenosis (AS),detected by color-flow Doppler echocardiography.The congenital quadricuspid aortic valve deformity in seven patients was diagnosed by echocardiography.All patients underwent successful aortic valve replacement.Conclusion Quadricuspid aortic valve is a rare cause of aortic insufficiency,while echocardiography plays an important role in diagnosing the disease.Aortic valve replacement is the major therapy for the disease.

  2. Experimental study on aortic remodeling in sinoaortic denervated rats

    Institute of Scientific and Technical Information of China (English)

    MIAO Chao-yu; TAO Xia; GUAN Yun-feng; YANG You-cai; CHU Zheng-xu; SU Ding-feng

    2001-01-01

    Objective: To study the aortic remodeling produced by chronic sinoaortic denervation (SAD) and its time course, and to study the role of humoral factor in the SAD-induced aortic remodeling. Methods: In rats with chronic SAD or sham operation, the aortic structure was measured by computer-assisted image analysis, the aortic function by isolated artery preparation, and angiotensin Ⅱ concentration by radioimmunoassay. Results and Conclusion: The aortic structural remodeling developed progressively at 4, 8, 16 and 32 weeks after SAD. Aortic structural remodeling after SAD expressed mainly as aortic hypertrophy due to SMC growth and collagen accumulation. The aortic contraction elicited by norepinephrine (NE) was progressively increased 8, 16 and 32 weeks after SAD. The aortic relaxation elicited by acetylcholine (ACh) was depressed 8, 16 and 32 weeks after SAD. In addition, in 32-week SAD rats the NE-induced contraction was not increased by endothelial denudation. These indicated that the increased contraction and depressed relaxation after SAD were related to the change of endothelium and/or the change of interaction between endothelium and SMC. In 10-week SAD rats, plasma angiotensin Ⅱ concentration remained unchanged, whereas aortic angiotensin Ⅱ concentration was significantly increased, suggesting that activation of tissue renin-angiotensin system may be involved in SAD-induced aortic remodeling.

  3. Aortic root, not valve, calcification correlates with coronary artery calcification in patients with severe aortic stenosis

    DEFF Research Database (Denmark)

    Henein, Michael; Hällgren, Peter; Holmgren, Anders;

    2015-01-01

    BACKGROUND: The underlying pathology in aortic stenosis (AS) and coronary artery stenosis (CAS) is similar including atherosclerosis and calcification. We hypothesize that coronary artery calcification (CAC) is likely to correlate with aortic root calcification (ARC) rather than with aortic valve...... calcification (AVC), due to tissue similarity between the two types of vessel rather than with the valve leaflet tissue. MATERIAL AND METHODS: We studied 212 consecutive patients (age 72.5 ± 7.9 years, 91 females) with AS requiring aortic valve replacement (AVR) in two Heart Centers, who underwent multidetector...... even after adjusting for age (p = 0.01). AVC score was associated with BAV after adjusting for age (p = 0.03) but ARC was not. Of the total cohort, 82 patients (39%) had significant coronary stenosis (>50%), but these were not different in the pattern of calcification from those without CAS. CAC...

  4. Computed tomography angiography of hybrid thoracic endovascular aortic repair of the aortic arch.

    Science.gov (United States)

    Akhtar, Nila J; Oderich, Gustavo S; Vrtiska, Terri J; Williamson, Eric E; Araoz, Philip A

    2013-05-01

    Endovascular repair of the aorta has traditionally been limited to the abdominal aorta and, more recently, the descending thoracic aorta. However, recently hybrid repairs (a combination of open surgical and endovascular repair) have made endovascular repair of the aortic arch possible. Hybrid repair of the aortic arch typically involves an open surgical debranching procedure that allows for revascularization of the aortic arch vessels and subsequent endovascular stent placement. These approaches avoid the deep hypothermic circulatory arrest required for full, open surgical repair of the aortic arch. In hybrid repairs, the stent landing zone determines which branch vessels will be covered and therefore need revascularization. This article will review the preprocedure assessment with computed tomography angiography, techniques for revascularization and postprocedure complications. PMID:23621141

  5. Cardiovascular magnetic resonance of quinticuspid aortic valve with aortic regurgitation and dilated ascending aorta

    OpenAIRE

    Zhang Zhaoqi; Zhang Lijun; Meng Yanfeng; Wang Yongmei; Yang Xiaoming

    2009-01-01

    Abstract We report a rare case of a quinticuspid aortic valve associated with regurgitation and dilation of the ascending aorta, which was diagnosed and post-surgically followed up by cardiovascular magnetic resonance and dual source computed tomography.

  6. Factors influencing long-term survival after aortic valve replacement.

    Directory of Open Access Journals (Sweden)

    Shigenobu,Masaharu

    1980-06-01

    Full Text Available In the aortic stenosis group, the left ventricular (LV muscle mass index was a good parameter for predicting the prognosis. Associated mitral valve disease had no influence on long term survival after aortic valve replacement. In the aortic insufficiency group, associated mitral valve disease had a marked influence on the results of aortic valve replacement. In general, the aortic insufficiency group had less clinical improvement postoperatively than the aortic stenosis group. In the annuloaortic ectasia group, left ventricular enddiastolic pressure (LVEDP might be the predictor to the prognosis. This group had the worst prognosis, of the three groups. Early operation should be considered for patients who have no, or only mild symptoms of, aortic valve disease.

  7. Marfan syndrome in children and adolescents: predictive and prognostic value of aortic root growth for screening for aortic complications

    OpenAIRE

    Groenink, M; Rozendaal, L; Naeff, M.S.J.; Hennekam, R.C.M.; Hart, A.A.M.; Wall; Mulder, B.J.M.

    1998-01-01

    Objective—To assess and measure the diagnostic and prognostic value of individual aortic root growth in children and adolescents with Marfan syndrome.
Design—From 1983 to 1996, 250 children were screened for Marfan syndrome. Serial echocardiographic aortic root measurements of 123 children (57 Marfan, 66 control) were available for evaluation of aortic root growth. Aortic root diameters were correlated with body surface area. Based on individual growth of the aortic root a discrimination form...

  8. The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography

    OpenAIRE

    Liu, Ying; Xu, Jian; Jian LI; Ren, Jing; LIU, HONGTAO; Xu, Junqing; Wei, Mengqi; Hao, Yuewen; Zheng, Minwen

    2013-01-01

    Background Aortic dissection is a lift-threatening medical emergency associated with high rates of morbidity and mortality. The incidence rate of aortic dissection is estimated at 5 to 30 per 1 million people per year. The prompt and correct diagnosis of aortic dissection is critical. This study was to compare the ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography and conventional dual-source CT angiography. Methods A total of 110 conse...

  9. Anatomics Knowledges of Aortic Root in the Transcatheter Aortic Valve Implantation.

    Directory of Open Access Journals (Sweden)

    Marcelo Cerezo

    2010-12-01

    Full Text Available The Aortic Valve is a valvular system that bears different high pressure forces. It takes part of a complex structure called Aortic Root. Nowadays, anatomic knowledge has taken a preponderant role, due to the use of the Transcatether Aortic Valve Implant (TAVI. To describe the patient´s characteristics which exclude them of the TAVI for anatomic reasons in cadaveric dissections and transthoracic echocardiograms. A descriptive retrospective analysis of 67 individuals was performed and divided into two groups. Group A: Formalized cadaveric dissections with hypertrofic hearts and aortic sclerosis signs from the Chair A of Anatomy of the University of La Plata (UNLP. Group B: Transthoracic Echocardiograms realized at the San Martín Hospital of La Plata between January 2005 and December 2009. Out of 67 individuals assessed, 17 (25% had one or more contraindications for TAVI. Five on Group A (36%, and 12 on Group B (23%. The most common anatomic contraindication was the Ascending Aortic diameter less than 30mm and the aortic annulus less than 20mm, following to the RAo-TSVI Angle more than 145° (2 to Group A, and 4 to Group B and the Septal thickness more than 17mm (no one to Group A, and 3 to Group B. Only just one individual was found with a low implant left coronary artery in the Group A avoiding TAVI. According to this study, the anatomic contraindications to realize TAVI are frequent due to the diagnosis devices available at the moment. The anatomic aortic root knowledge and the aortic valve interindividual variability will allow the improvement of the manufactured devices made in the market.

  10. The High Altitude Balloon Experiment demonstration of acquisition, tracking, and pointing technologies (HABE-ATP)

    Science.gov (United States)

    Dimiduk, D.; Caylor, M.; Williamson, D.; Larson, L.

    1995-01-01

    The High Altitude Balloon Experiment demonstration of Acquisition, Tracking, and Pointing (HABE-ATP) is a system built around balloon-borne payload which is carried to a nominal 26-km altitude. The goal is laser tracking thrusting theater and strategic missiles, and then pointing a surrogate laser weapon beam, with performance levels end a timeline traceable to operational laser weapon system requirements. This goal leads to an experiment system design which combines hardware from many technology areas: an optical telescope and IR sensors; an advanced angular inertial reference; a flexible multi-level of actuation digital control system; digital tracking processors which incorporate real-time image analysis and a pulsed, diode-pumped solid state tracking laser. The system components have been selected to meet the overall experiment goals of tracking unmodified boosters at 50- 200 km range. The ATP system on HABE must stabilize and control a relative line of sight between the platform and the unmodified target booster to a 1 microrad accuracy. The angular pointing reference system supports both open loop and closed loop track modes; GPS provides absolute position reference. The control system which positions the line of sight for the ATP system must sequence through accepting a state vector handoff, closed-loop passive IR acquisition, passive IR intermediate fine track, active fine track, and then finally aimpoint determination and maintenance modes. Line of sight stabilization to fine accuracy levels is accomplished by actuating wide bandwidth fast steering mirrors (FSM's). These control loops off-load large-amplitude errors to the outer gimbal in order to remain within the limited angular throw of the FSM's. The SWIR acquisition and MWIR intermediate fine track sensors (both PtSi focal planes) image the signature of the rocket plume. After Hard Body Handover (HBHO), active fine tracking is conducted with a visible focal plane viewing the laser-illuminated target

  11. Long-term follow-up after embolization of pulmonary arteriovenous malformations with detachable silicone balloons

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Kjeldsen, Anette D

    2007-01-01

    ) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not...

  12. Three dimensional intravascular ultrasonic assessment of the local mechanism of restenosis after balloon angioplasty

    NARCIS (Netherlands)

    M.A. Costa (Marco); P.J. de Feyter (Pim); K. Kozuma (Ken); A.L. Gaster; M. Sabaté (Manel); I.P. Kay (Ian Patrick); J.M.R. Ligthart (Jürgen); P. Thayssen; M.J.B.M. van den Brand (Marcel); P.W.J.C. Serruys (Patrick); D.P. Foley (David); W.J. van der Giessen (Wim)

    2001-01-01

    textabstractOBJECTIVE: To assess the mechanism of restenosis after balloon angioplasty. DESIGN: Prospective study. PATIENTS: 13 patients treated with balloon angioplasty. INTERVENTIONS: 111 coronary subsegments (2 mm each) were analysed after balloon angioplasty and at a six month follow up using th

  13. Percutaneous transcatheter aortic valve implantation for degenerated surgical bioprostheses: the first case series in Asia with one-year follow-up

    Science.gov (United States)

    Chiam, Paul Toon Lim; Ewe, See Hooi; Soon, Jia Lin; Ho, Kay Woon; Sin, Yong Koong; Tan, Swee Yaw; Lim, Soo Teik; Koh, Tian Hai; Chua, Yeow Leng

    2016-01-01

    INTRODUCTION Percutaneous transcatheter aortic valve implantation (TAVI) has become an established therapy for inoperable and high-surgical-risk patients with severe aortic stenosis. Although TAVI in patients with degenerated surgical aortic bioprostheses (i.e. valve-in-valve TAVI) is increasingly reported in Western studies, such data is lacking in Asian patients. We describe the initial experience of valve-in-valve TAVI in Asia. METHODS Eight patients who underwent valve-in-valve TAVI due to degenerated aortic bioprostheses were enrolled. The mechanism of bioprosthetic valve failure was stenotic, regurgitation or mixed. All procedures were performed via transfemoral arterial access, using the self-expanding CoreValve prosthesis or balloon-expandable SAPIEN XT prosthesis. RESULTS The mean age of the patients was 71.6 ± 13.2 years and five were male. Mean duration to surgical bioprosthesis degeneration was 10.2 ± 4.1 years. Valve-in-valve TAVI was successfully performed in all patients. CoreValve and SAPIEN XT prostheses were used in six and two patients, respectively. There were no deaths, strokes or permanent pacemaker requirement at 30 days, with one noncardiac mortality at one year. All patients experienced New York Heart Association functional class improvement. Post-procedure mean pressure gradients were 20 ± 11 mmHg and 22 ± 8 mmHg at 30 days and one year, respectively. Residual aortic regurgitation (AR) of more than mild severity occurred in one patient at 30 days. At one year, only one patient had mild residual AR. CONCLUSION In our experience of valve-in-valve TAVI, procedural success was achieved in all patients without adverse events at 30 days. Good clinical and haemodynamic outcomes were sustained at one year. PMID:27193081

  14. Safety and efficacy of using the Viabahn endoprosthesis for percutaneous treatment of vascular access complications after transfemoral aortic valve implantation

    DEFF Research Database (Denmark)

    De Backer, Ole; Arnous, Samer; Sandholt, Benjamin;

    2015-01-01

    Vascular access complications (VACs) remain one of the biggest challenges when performing transcatheter aortic valve implantation (TAVI). This study aimed to investigate the short- and medium-term safety and efficacy of the Viabahn endoprosthesis (Gore, Flagstaff, AZ) when used to treat TAVI......-induced vascular injury. Over a 40-month period, 354 patients underwent true percutaneous transfemoral (TF)-TAVI using a CoreValve and Prostar-XL closure system; this was our study population. A VAC leading to acute intervention occurred in 72 patients (20.3%) - of these, 18 were managed by balloon angioplasty, 48...... stenting versus patients without vascular complications. Two patients (4.5%) presented with new-onset claudication; one of them had the stent implanted covering the deep femoral artery (DFA). At medium-term follow-up (median 372 days; range 55 to 978 days) duplex ultrasound showed 100% patency...

  15. Surgical Treatment of Aortic Aneurysm and Aortic Dissection:A Retrospective Analysis of 122 Cases

    Institute of Scientific and Technical Information of China (English)

    Tucheng SUN; Xionggang JIANG; Kailun ZHANG; Jie CAI; Shu CHEN; NYANGASSA B J; Zongquan SUN

    2009-01-01

    The study summarizes the clinical experience of surgical treatments of various types of thoracic aneurysm and aortic dissection.Clinical data of 122 patients with thoracic aneurysm and aortic dissection during July 2005 to July 2008 were retrospectively analyzed.The elective operations were performed in 107 patients while emergency surgery was done in 15 cases.Different surgical strategies were employed on the basis of diseased region,including simple ascending aortic replacement (n=3),aortic root replacement (n=43),hemi-arch replacement/total arch replacement + elephant trunk technique (n=32),thoracic/thoracoabdominal aortic replacement (n=8) and endovascular repair (n=36).In this series,there is 4 cases of perioperative death due to massive cerebral hemorrhage (n=1),respiratory failure (n=1) and multiple organ dysfunction syndrome (MODS) (n=2).Three cases developed post-operative massive cerebral infarction and the relatives of the patients abandoned treatment.Instant success rate of endovascular repair was 100%.The intimal rupture was sealed.Blood flow was unobstructed in true lumen and no false lumen was visualized.It was concluded that aggressive surgery should be considered in the patients with thoracic aneurysm and aortic dissection.Surgical procedures should vary with the location and the nature of the lesions.

  16. Ultrasonic delineation of aortic microstructure: The relative contribution of elastin and collagen to aortic elasticity

    Science.gov (United States)

    Marsh, Jon N.; Takiuchi, Shin; Lin, Shiow Jiuan; Lanza, Gregory M.; Wickline, Samuel A.

    2004-05-01

    Aortic elasticity is an important factor in hemodynamic health, and compromised aortic compliance affects not only arterial dynamics but also myocardial function. A variety of pathologic processes (e.g., diabetes, Marfan's syndrome, hypertension) can affect aortic elasticity by altering the microstructure and composition of the elastin and collagen fiber networks within the tunica media. Ultrasound tissue characterization techniques can be used to obtain direct measurements of the stiffness coefficients of aorta by measurement of the speed of sound in specific directions. In this study we sought to define the contributions of elastin and collagen to the mechanical properties of aortic media by measuring the magnitude and directional dependence of the speed of sound before and after selective isolation of either the collagen or elastin fiber matrix. Formalin-fixed porcine aortas were sectioned for insonification in the circumferential, longitudinal, or radial direction and examined using high-frequency (50 MHz) ultrasound microscopy. Isolation of the collagen or elastin fiber matrices was accomplished through treatment with NaOH or formic acid, respectively. The results suggest that elastin is the primary contributor to aortic medial stiffness in the unloaded state, and that there is relatively little anisotropy in the speed of sound or stiffness in the aortic wall.

  17. Medtronic Freestyle Aortic Root Bioprosthesis Implantation for the Infective Endocarditis on Aortic Root

    Directory of Open Access Journals (Sweden)

    Zekeriya Arslan

    2013-10-01

    Full Text Available    Infective endocarditis and periannular abscess formation are serious problems in cardiac valve surgery, requiring extensive surgical debridement and reconstruction of the aortic annulus. We aimed to report two cases which were successfully treated with bioprosthetic valve implantation for infective endocarditis. Transosephageal echocardiography were performed for the diagnosis of one prosthetic and one native destructive aortic valve endocarditis in association with congestive heart failure (NYHA class-VI and abscess formation. Medtronic Freestyle stentless aortic root bioprosthesis was implanted into the left ventricular outflow tract after surgical radical aortic root debridement for each patient followed with medical treatment, which was extended to six weeks. Neither early nor late mortality was detected. One patient required prolonged ventilatory support (two days and permanent DDD-R pacing. Echocardiography showed no signs of valve dysfunction or recurrent endocarditis for both patients in 10 months follow up.Medtronic Freestyle stentless aortic root bioprosthesis may be a good alternative way of treatment to aortic valve and root endocarditis instead of homograft.

  18. Aorto-right atrial fistula after ascending aortic replacement or aortic value replacement

    International Nuclear Information System (INIS)

    Objective: To evaluate the CT features of aorto-right atrial fistula after aortic valve replacement (AVR) or ascending aortic replacement. Methods: Eighty-seven patients with aortic-right atrial fistula underwent CT after operation. The CT features were retrospectively analyzed. Fistula was measured according to maximum width of the shunt. Results: Aorto-right atrial fistula was detected in 87 patients after aortic valve replacement or ascending aortic replacement by CT scan. Among them, 25 patients were diagnosed as mild aorto-right atrial fistula, 47 patients as moderate, and 15 patients as severe. Thirty-seven patients underwent follow-up CT.Among them, 10 patients with mild to moderate aorto-right atrial fistula were considered to have complete regression, 8 patients with mild aorto-right atrial fistula considered to have incomplete regression, 14 patients with mild to moderate aorto-right atrial fistula considered to have stable condition, and 5 patients with moderate aorto-right atrial fistula considered to have progression at the 3-month follow-up. Conclusion: CT is a useful tool for defining aorto-right atrial fistula after AVR or ascending aortic replacement and for evaluating it in follow-up. (authors)

  19. Utility of balloon assisted technique in trans catheter closure of very large (≥35 mm) atrial septal defects

    Science.gov (United States)

    Rangaswamy Balasubramanian, Vidhyakar; Selvaraj, Raja; Saktheeswaran, Maheshkumar; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    Background Very few published data is available on the outcomes of balloon assisted techniques (BATs) for trans catheter closure (TCC) of very large (Defined as ≥35 mm size) ostium secundum atrial septal defect (ASD). Objective To study the utility of BAT as against conventional techniques (CT) in TCC of very large ostium secundum ASD (≥35 mm) over the past 5-year period and to find out the association of different morphological features of the defects in relation to TCC outcomes. Study design and methods Descriptive single center retrospective study of patients with very large ostium secundum ASD (≥35 mm size) who were subjected to TCC. Results Thirty-three out of 36 patients with ≥35 mm ASD and complex morphological features underwent successful TCC. The study patients had high prevalence of absent aortic and posterior rims with posterior mal-alignment of the septum. BAT was successful in 28/31 (90.3%) patients while CT had a success rate of 16%. The mean trans-esophageal echocardiography (TEE) ASD size with BAT success 37 (SD 1.3) mm and CT failure 36.2 (SD 1.1) mm was not different (P=0.06). On univariate analysis of different morphological features, posterior mal alignment of the septum was associated failure of CT (P=0.01). There was no urgent referral for surgery and patients did well on follow up. Conclusions Balloon assisted device closure of (≥35 mm) ASD had 90% success rate. BAT helps in controlled delivery and device alignment in very large ASD with posterior malalignment of the septum and is often helpful when CT fails. PMID:24649421

  20. Evaluation of a physiologic pulsatile pump system for neonate-infant cardiopulmonary bypass support.

    Science.gov (United States)

    Undar, A; Masai, T; Inman, R; Beyer, E A; Mueller, M A; McGarry, M C; Frazier, O H; Fraser, C D

    1999-01-01

    An alternate physiologic pulsatile pump (PPP) system was designed and evaluated to produce sufficient pulsatility during neonate-infant open heart surgery. This hydraulically driven pump system has a unique "dual" pumping chamber mechanism. The first chamber is placed between the venous reservoir and oxygenator and the second chamber between the oxygenator and patient. Each chamber has two unidirectional tricuspid valves. Stroke volume (0.2-10 ml), upstroke rise time (10-350 msec), and pump rate (2-250 beats per minute [bpm]) can be adjusted independently to produce adequate pulsatility. This system has been tested in 3-kg piglets (n = 6), with a pump flow of 150 ml/kg/min, a pump rate of 150 bpm, and a pump ejection time of 110 msec. After initiation of cardiopulmonary bypass (CPB), all animals were subjected to 25 minutes of hypothermia to reduce the rectal temperatures to 18 degrees C, 60 minutes of deep hypothermic circulatory arrest (DHCA), then 10 minutes of cold perfusion with a full pump flow, and 40 minutes of rewarming. During CPB, mean arterial pressures were kept at less than 50 mm Hg. Mean extracorporeal circuit pressure (ECCP), the pressure drop of a 10 French aortic cannula, and the pulse pressure were 67+/-9, 21+/-6, and 16+/-2 mm Hg, respectively. All values are represented as mean+/-SD. No regurgitation or abnormal hemolysis has been detected during these experiments. The oxygenator had no damping effect on the quality of the pulsatility because of the dual chamber pumping mechanism. The ECCP was also significantly lower than any other known pulsatile system. We conclude that this system, with a 10 French aortic cannula and arterial filter, produces adequate pulsatility in 3 kg piglets. PMID:9952008