WorldWideScience

Sample records for aortic balloon pump

  1. Management of intra-aortic balloon pumps.

    Science.gov (United States)

    Webb, Christopher A-J; Weyker, Paul D; Flynn, Brigid C

    2015-06-01

    Intra-aortic balloon pumps (IABPs) continue to be the most widely used cardiac support devices with an annual estimate of 200 000 IABPs placed worldwide. IABPs enhance myocardial function by maximizing oxygen supply and minimizing oxygen demand. The use of IABPs is not without risk, with major vascular injury, ischemia, and infection being the most common complications, especially in high-risk patients. While recent studies have questioned the use of IABPs in patients with cardiogenic shock secondary to myocardial infarction, these studies have limitations making it difficult to formulate definitive conclusions. This review will focus on the mechanisms of counterpulsation, the management of IABPs and the evidence supporting this ventricular support therapy. © The Author(s) 2014.

  2. Predictors of cardiogenic shock in cardiac surgery patients receiving intra-aortic balloon pumps.

    Science.gov (United States)

    Iyengar, Amit; Kwon, Oh Jin; Bailey, Katherine L; Ashfaq, Adeel; Abdelkarim, Ayman; Shemin, Richard J; Benharash, Peyman

    2018-02-01

    Cardiogenic shock after cardiac surgery leads to severely increased mortality. Intra-aortic balloon pumps may be used during the preoperative period to increase coronary perfusion. The purpose of this study was to characterize predictors of postoperative cardiogenic shock in cardiac surgery patients with and without intra-aortic balloon pumps support. We performed a retrospective analysis of our institutional database of the Society of Thoracic Surgeons for patients operated between January 2008 to July 2015. Multivariable logistic regression was used to model postoperative cardiogenic shock in both the intra-aortic balloon pumps and matched control cohorts. Overall, 4,741 cardiac surgery patients were identified during the study period, of whom 192 (4%) received a preoperative intra-aortic balloon pump. Intra-aortic balloon pumps patients had a greater prevalence of diabetes, previous cardiac surgery, congestive heart failure, and an urgent/emergent status (P pumps patients also had greater 30-day mortality and more postoperative cardiogenic shock (9% vs 3%, P pumps cohort, only sex, previous percutaneous coronary intervention and preoperative arrhythmia remained significant on multivariable analysis (all P pumps and those who do not. Further analysis of the effects of prophylactic intra-aortic balloon pumps support is warranted. (Surgery 2017;160:XXX-XXX.). Copyright © 2017 Elsevier Inc. All rights reserved.

  3. The effects of intra-aortic balloon pump in coronary stenting for high risk patients

    International Nuclear Information System (INIS)

    Zhang Qi; Shen Weifeng; Zhang Jianshen; Zhang Ruiyan; Hu Jian; Zhang Xian

    2003-01-01

    Objective: To evaluate the therapeutic efficacy of intra-aortic balloon supporting in coronary interventions for high risk patients with coronary artery disease (CAD). Methods: Sixteen high risk CAD patients accepted percutaneous coronary intervention assisted by intra-aortic balloon pumping together with clinical variables, procedural and follow-up informations were recorded and evaluated. Results: All patients presented with severe left ventricular dysfunction, multi-vessel disease and high jeopardy scores. 12 patients acquired complete revascularization. Mean duration of balloon pumping was (31 ± 17) minutes. Aortic diastolic and mean pressures were increased during balloon pumping [diastolic: (69±11) mmHg pre. vs (131±15) mmHg post.; mean: (82±13) mmHg pre. vs (111±7) mmHg post., P<0.001]. With average of 2 years follow-up, one patient died from pump failure but no MACE reaching survival rate of 75%. The ejection fraction and the NYHA grade were significantly improved. Conclusions: Intra-aortic balloon pumping is a safe and effective method in treating high risk CAD patients obtaining rather fare prognosis

  4. Loss of Guide Wire: A Rare Complication of Intra-Aortic Balloon Pump Insertion

    Directory of Open Access Journals (Sweden)

    Manouchehr Hekmat

    2015-10-01

    Full Text Available At the final stages of a coronary artery bypass graft operation on a 64-year-old man, an experienced physician attempted to insert an intra-aortic balloon pump into the femoral artery via the Seldinger technique. However, while the balloon pump was being passed over the guide wire, the latter was completely lost.The guide wire should be held at the tip at all times to prevent passage into the vessel. Strict adherence to this rule will prevent guide-wire loss, which is, albeit rare and completely avoidable, a potentially life-threatening complication of central vein or artery catheterization, with reported fatality rates of up to 20% when the whole wire is lost. The literature contains several reports on guide-wire loss during central venous, arterial, and hemodialysis catheterization, but we report for the first time the loss of a guide wire as a rare complication of intra-aortic balloon pump insertion.

  5. Contemporary trends in cardiogenic shock: Incidence, intra-aortic balloon pump utilisation and outcomes from the London Heart Attack Group.

    Science.gov (United States)

    Rathod, Krishnaraj S; Koganti, Sudheer; Iqbal, M Bilal; Jain, Ajay K; Kalra, Sundeep S; Astroulakis, Zoe; Lim, Pitt; Rakhit, Roby; Dalby, Miles C; Lockie, Tim; Malik, Iqbal S; Knight, Charles J; Whitbread, Mark; Mathur, Anthony; Redwood, Simon; MacCarthy, Philip A; Sirker, Alexander; O'Mahony, Constantinos; Wragg, Andrew; Jones, Daniel A

    2018-02-01

    Cardiogenic shock remains a major cause of morbidity and mortality in patients with ST-segment elevation myocardial infarction. We aimed to assess the current trends in cardiogenic shock management, looking specifically at the incidence, use of intra-aortic balloon pump therapy and outcomes in patients with ST-segment elevation myocardial infarction treated with primary percutaneous coronary intervention. We undertook an observational cohort study of 21,210 ST-segment elevation myocardial infarction patients treated between 2005-2015 at the eight Heart Attack Centres in London, UK. Patients' details were recorded at the time of the procedure into local databases using the British Cardiac Intervention Society percutaneous coronary intervention dataset. There were 1890 patients who presented with cardiogenic shock. The primary outcome was all-cause mortality at a median follow-up of 4.1 years (interquartile range: 2.2-5.8 years). Increasing rates of cardiogenic shock were seen over the course of the study with consistently high mortality rates of 45-70%. A total of 685 patients underwent intra-aortic balloon pump insertion during primary percutaneous coronary intervention for cardiogenic shock with decreasing rates over time. Those patients undergoing intra-aortic balloon pump therapy were younger, more likely to have poor left ventricular function and less likely to have had previous percutaneous coronary intervention compared to the control group. Procedural success rates were similar (86.0% vs 87.1%, p=0.292) although crude, in-hospital major adverse cardiac event rates were higher (43.8% vs 33.7%, p<0.0001) in patients undergoing intra-aortic balloon pump therapy. Kaplan-Meier analysis demonstrated significantly higher mortality rates in patients receiving intra-aortic balloon pump therapy (50.9% intra-aortic balloon pump vs 39.9% control, p<0.0001) during the follow-up period. After multivariate Cox analysis (hazard ratio 1.04, 95% confidence interval 0

  6. Stimulus-response time to alarms of the intra-aortic balloon pump: safe care practices

    Directory of Open Access Journals (Sweden)

    Andrezza Serpa Franco

    Full Text Available ABSTRACT Objective: To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. Method: This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. Results: The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. Conclusion: Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology.

  7. Usefulness of intra-aortic balloon pump counterpulsation in patients with cardiogenic shock from acute myocardial infarction

    NARCIS (Netherlands)

    Cheng, Jin M.; Valk, Suzanne D. A.; den Uil, Corstiaan A.; van der Ent, Martin; Lagrand, Wim K.; van de Sande, Meike; van Domburg, Ron T.; Simoons, Maarten L.

    2009-01-01

    Although intra-aortic balloon pump (IABP) counterpulsation is increasingly being used for the treatment of patients with cardiogenic shock from acute myocardial infarction, data on the long-term outcomes are lacking. The aim of the present study was to evaluate the 30-day and long-term mortality and

  8. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous

    NARCIS (Netherlands)

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N.; Pijls, Nico H. J.; de Mol, Bas A.; Rutten, Marcel C. M.

    2011-01-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in

  9. A survey on the use of intra-aortic balloon pump in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Elena Bignami

    2012-01-01

    Full Text Available Intra-aortic balloon pump (IABP is an established tool in the management of cardiac dysfunction in cardiac surgery. The best timing for IABP weaning is unknown and varies greatly among cardiac centers. The authors investigated the differences in IABP management among 66 cardiac surgery centers performing 40,675 cardiac surgery procedures in the 12-month study period. The centers were contacted through email, telephone, or in person interview. IABP management was very heterogeneous in this survey: In 43% centers it was routinely removed on the first postoperative day, and in 34% on the second postoperative day. In 50% centers, it was routinely removed after extubation of the patients whereas in 15% centers it was removed while the patients were sedated and mechanically ventilated. In 66% centers, patients were routinely receiving pharmacological inotropic support at the time of removal of IABP. The practice of decreasing IABP support was also heterogeneous: 57% centers weaned by reducing the ratio of beat assistance whereas 34% centers weaned by reducing balloon volume. We conclude that the management of IABP is heterogeneous and there is a need for large prospective studies on the management of IABP in cardiac surgery.

  10. The Evaluation of Survival in Patients Who Need Intra aortic Balloon Pump (IABP after Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Behrooz Mottahedi

    2014-11-01

    Full Text Available Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In this retrospective cohort study 235 patients requiring LABP support were analyzed over 14 years period (between January 1999 and December 2013 from which 137 patients survived the 30 days follow-up. Perioperative and demographic factors such as age, weight, underlying disease, ejection fraction, ventricular aneurysm and cardiopulmonary bypass and cross clamp time were recorded and analyzed.   Results: The overall operative mortality was reported to be 41.7%. Male-to-female ratio was 131:104 and the mean age of the subjects was 57.58 ± 11.07 years. Early mortality rate was higher among young subjects and those with prolonged CBP (162.71±35.25, P

  11. The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome

    Directory of Open Access Journals (Sweden)

    Apostolakis Efstratios

    2010-04-01

    Full Text Available Abstract Background The early and intermediate outcome of patients requiring intraaortic balloon pump (IABP was studied in a cohort of 2697 adult cardiac surgical patients. Methods 136 patients requiring IABP (5.04% support analysed over a 4 year period. Prospective data collection, obtained. Results The overall operative mortality was 35.3%. The "operation specific" mortality was higher on the Valve population. The mortality (% as per time of balloon insertion was: Preoperative 18.2, Intraopeartive 33.3, postoperative 58.3 (p The incremental risk factors for death were: Female gender (Odds Ratio (OR = 3.87 with Confidence Intervals (CI = 1.3-11.6, Smoking (OR = 4.88, CI = 1.23- 19.37, Preoperative Creatinine>120 (OR = 3.3, CI = 1.14-9.7, Cross Clamp time>80 min (OR = 4.16, CI = 1.73-9.98 and IABP insertion postoperatively (OR = 19.19, CI = 3.16-116.47. The incremental risk factors for the development of complications were: Poor EF (OR = 3.16, CI = 0.87-11.52, Euroscore >7 (OR = 2.99, CI = 1.14-7.88, history of PVD (OR = 4.99, CI = 1.32-18.86. The 5 years survival was 79.2% for the CABG population and 71.5% for the valve group. (Hazard ratio = 1.78, CI = 0.92-3.46. Conclusions IABP represents a safe option of supporting the failing heart. The need for IABP especially in a high risk Valve population is associated with early unfavourable outcome, however the positive mid term results further justify its use.

  12. The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome.

    LENUS (Irish Health Repository)

    Parissis, Haralabos

    2010-01-01

    BACKGROUND: The early and intermediate outcome of patients requiring intraaortic balloon pump (IABP) was studied in a cohort of 2697 adult cardiac surgical patients. METHODS: 136 patients requiring IABP (5.04%) support analysed over a 4 year period. Prospective data collection, obtained. RESULTS: The overall operative mortality was 35.3%. The "operation specific" mortality was higher on the Valve population.The mortality (%) as per time of balloon insertion was: Preoperative 18.2, Intraoperative 33.3, postoperative 58.3 (p < 0.05).The incremental risk factors for death were: Female gender (Odds Ratio (OR) = 3.87 with Confidence Intervals (CI) = 1.3-11.6), Smoking (OR = 4.88, CI = 1.23- 19.37), Preoperative Creatinine>120 (OR = 3.3, CI = 1.14-9.7), Cross Clamp time>80 min (OR = 4.16, CI = 1.73-9.98) and IABP insertion postoperatively (OR = 19.19, CI = 3.16-116.47).The incremental risk factors for the development of complications were: Poor EF (OR = 3.16, CI = 0.87-11.52), Euroscore >7 (OR = 2.99, CI = 1.14-7.88), history of PVD (OR = 4.99, CI = 1.32-18.86).The 5 years survival was 79.2% for the CABG population and 71.5% for the valve group. (Hazard ratio = 1.78, CI = 0.92-3.46). CONCLUSIONS: IABP represents a safe option of supporting the failing heart. The need for IABP especially in a high risk Valve population is associated with early unfavourable outcome, however the positive mid term results further justify its use.

  13. Using Intra-Aortic Balloon Pump for Management of Cardiogenic Shock Following Aluminum Phosphide Poisoning; Report of 3 Cases.

    Science.gov (United States)

    Bagheri-Moghaddam, Ahmad; Abbaspour, Hasan; Tajoddini, Shahrad; Mohammadzadeh, Vahideh; Moinipour, Ali; Dadpour, Bita

    2018-01-01

    Aluminium phosphide (Alp) poisoning mortality rate has been reported as high as 70-100%, and refractory hypotension and cardiogenic shock are the two most common presentations leading to death. Due to lack of specific antidote, all treatments are focused on supportive care and recently, intra-aortic balloon pump (IABP) has been suggested to treat cardiogenic shock resulting from toxic myocarditis. In the current paper, we introduce three Alp poisoned patients for whom IABP was applied to manage their refractory shock. Two men and one woman who were admitted to emergency department (ED) of Imam Reza academic Hospital, Mashhad, Iran due to intentional Alp poisoning are reported. The cases visited the ED shortly after ingestion and nearly all of them showed hypotension, tachycardia and metabolic acidosis during early hospitalization. Due to persistent shock state, despite receiving intravenous fluid therapy and vasopressor agents, IABP insertion was performed in these cases. Finally, one of them survived and the other two died. It still cannot be decided whether IABP insertion is effective in cases of Alp poisoning or not. It might be reasonable to try this intervention along with other conservative treatments in patients who survive more than 12 hours and consistently suffer from refractory hypotension.

  14. [Status of intra-aortic balloon pump application and related factors in Chinese patients with acute myocardial infarction].

    Science.gov (United States)

    Wu, N Q; Gao, Z; Zheng, Y; Li, W; Li, J N; Xu, H Y; Cheng, X S; Wu, Y; Wang, Y; Wang, Z J; Yang, J G; Yang, Y J

    2018-01-24

    Objective: To investigate the current status of application of intra-aortic balloon pump(IABP) and analyze the factors which might impact the application of IABP in patients with acute myocardial infarction complicated with cardiac shock in China. Methods: In China Acute Myocardial Infarction (CAMI) Registry,a nationwide, multicenter(107 hospitals), prospective study, 26 592 patients with acute myocardial infarction were enrolled consecutively between January 1, 2013 and September 30, 2014. After excluding of 30 cases due to missing important data,26 562 cases were analyzed.The application status of IABP was analyzed and multivariate logistic regression analysis was performed to determine the factors related to IABP application. Results: A total of 785(3.0%) patients with acute myocardial infarction received IABP implantation, and 381(49.9%) patients belonged to preventive application of IABP before primary percutaneous coronary intervention,and 6(0.8%) patients were complicated with mechanical complications.There were 118(15.0%) patients with cardiac shock received IABP implantation, which accounted for 12.0%(118/984) of all patients with cardiac shock.Multivariate logistic regression analysis showed that the clinical independent factors of the decision of IABP insertion included dyslipidemia ( OR= 2.858, 95% CI 1.397-5.846, P= 0.004),left ventricular ejection fraction ( OR= 0.977, 95% CI 0.961-0.994, P= 0.009),usage of dopamine ( OR= 2.817, 95% CI 1.495-5.308, P= 0.001), left main disease ( OR= 2.817, 95% CI 1.495-5.308, P= 0.001), GRACE score ( OR= 1.006, 95% CI 1.000-1.011, P= 0.034), receiving primary percutaneous coronary intervention ( OR= 4.508, 95% CI 1.673-12.146, P= 0.003), teritiary hospitals ( OR= 2.562, 95% CI 1.498-4.384, P= 0.001), and higher education of the patients ( OR= 2.183, 95% CI 1.056-4.509, P= 0.016). Conclusions: Among the Chinese acute myocardial infarction patients who received IABP implantation, nearly half application of IABP are

  15. Factors associated with pulmonary dysfunction in patients undergoing coronary artery bypass graft surgery with use of intra-aortic balloon pump.

    Science.gov (United States)

    Amaral Gonçalves Fusatto, Helena; Castilho de Figueiredo, Luciana; Ragonete Dos Anjos Agostini, Ana Paula; Sibinelli, Melissa; Dragosavac, Desanka

    2018-01-01

    The aim of this study was to identify pulmonary dysfunction and factors associated with prolonged mechanical ventilation, hospital stay, weaning failure and mortality in patients undergoing coronary artery bypass grafting with use of intra-aortic balloon pump (IABP). This observational study analyzed respiratory, surgical, clinical and demographic variables and related them to outcomes. We analyzed 39 patients with a mean age of 61.2 years. Pulmonary dysfunction, characterized by mildly impaired gas exchange, was present from the immediate postoperative period to the third postoperative day. Mechanical ventilation time was influenced by the use of IABP and PaO2/FiO2, female gender and smoking. Intensive care unit (ICU) stay was influenced by APACHE II score and use of IABP. Mortality was strongly influenced by APACHE II score, followed by weaning failure. Pulmonary dysfunction was present from the first to the third postoperative day. Mechanical ventilation time was influenced by female gender, smoking, duration of IABP use and PaO2/FiO2 on the first postoperative day. ICU stay was influenced by APACHE II score and duration of IABP. Mortality was influenced by APACHE II score, followed by weaning failure. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Temporal Trends of In-Hospital Mortality in Patients Treated with Intra-Aortic Balloon Pumping: A Nationwide Population Study in Taiwan, 1998-2008.

    Directory of Open Access Journals (Sweden)

    Chung-Han Ho

    Full Text Available Intra-aortic balloon pumping (IABP is widely used for hemodynamic support in critical patients with cardiogenic shock (CS. We examined whether the in-hospital mortality of patients in Taiwan treated with IABP has recently declined. We used Taiwan's National Health Insurance Research Database to retrospectively review the in-hospital all-cause mortality of 9952 (7146 men [71.8%] 18-year-old and older patients treated with IABP between 1998 and 2008. The mortality rate was 13.84% (n = 1377. The urbanization levels of the hospitals, and the number of days in the intensive care unit, of hospitalization, and of IABP treatment, and prior percutaneous coronary intervention (PCI were associated with mortality. Seven thousand six hundred thirty-five patients (76.72% underwent coronary artery bypass grafting (CABG surgery, and 576 (5.79% underwent high-risk PCI with IABP treatment. The number of patients treated with IABP significantly increased during this decade (ptrend < 0.0001, the in-hospital all-cause mortality for patients treated with IABP significantly decreased (ptrend = 0.0243, but the in-hospital all-cause mortality of patients who underwent CABG and PCI plus IABP did not decrease. In conclusion, the in-hospital mortality rate of IABP treatment decreased annually in Taiwan during the study period. However, high-risk patients who underwent coronary revascularization with IABP had a higher and unstable in-hospital mortality rate.

  17. Intra-aortic balloon pump combined with mechanical ventilation for treating patients aged > 60 years in cardiogenic shock: Retrospective analysis.

    Science.gov (United States)

    Liu, Hongwei; Wu, Xueping; Zhao, Xiaoning; Zhu, Ping; Han, Lina

    2016-06-01

    To examine if mechanical ventilation with positive end-expiratory pressure (PEEP) combined with intra-aortic balloon pump (IABP) provided a better outcome than IABP alone for the treatment of cardiogenic shock after acute myocardial infarction in patients aged > 60 years. This was a retrospective analysis of data from patients in cardiogenic shock, refractory to pharmacological therapy and treated at a geriatric coronary care unit. Sixty-two patients were eligible for study inclusion: 33 received IABP alone; 29 received IABP combined with mechanical ventilation. Patients in the IABP + mechanical ventilation group had lower mean arterial blood pressure (BP), systolic BP and partial pressure of oxygen compared with the IABP group, indicating worse cardiac and pulmonary function. In addition, higher rates of pulmonary infection and renal insufficiency were observed in the IABP + mechanical ventilation group than in the IABP group. A statistically significant improvement of left ventricular function before and after treatment was observed in the IABP + mechanical ventilation group, but not in the IABP group. Pulmonary infection and renal insufficiency were risk factors for all-cause in-hospital mortality; successful revascularization was a negative risk factor. There was no between-group difference in survival. Mechanical ventilation with an appropriate level of PEEP appears to enhance the beneficial effects of IABP on left ventricular function for patients in cardiogenic shock. © The Author(s) 2016.

  18. Inflation and deflation timing of the AutoCAT 2 WAVE intra-aortic balloon pump using the autoPilot mode in a clinical setting.

    Science.gov (United States)

    Bakker, E W M; Visser, K; van der Wal, A; Kuiper, M A; Koopmans, M; Breedveld, R

    2012-09-01

    The primary goal of this observational clinical study was to register the occurrence of incorrect inflation and deflation timing of an intra-aortic balloon pump in autoPilot mode. The secondary goal was to identify possible causes of incorrect timing. During IABP assistance of 60 patients, every four hours a strip was printed with the IABP frequency set to 1:2. Strips were examined for timing discrepancies beyond 40 ms from the dicrotic notch (inflation) and the end of the diastolic phase (deflation). In this way, 320 printed strips were examined. A total of 52 strips (16%) showed incorrect timing. On 24 of these strips, the incorrect timing was called incidental, as it showed on only one or a few beats. The other 28 cases of erroneous timing were called consistent, as more than 50% of the beats on the strip showed incorrect timing. We observed arrhythmia in 69% of all cases of incorrect timing. When timing was correct, arrhythmia was found on 13 (5%) of 268 strips. A poor quality electrocardiograph (ECG) signal showed on 37% of all strips with incorrect timing and 11% of all strips with proper timing. We conclude that inflation and deflation timing of the IABP is not always correct when using the autoPilot mode. The quality of the ECG input signal and the occurrence of arrhythmia appear to be related to erroneous timing. Switching from autoPilot mode to operator mode may not always prevent incorrect timing.

  19. Clinical therapeutic efficacy of intra-aortic balloon pump as an adjuvant treatment after percutaneous coronary intervention in patients with coronary heart disease associated with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Zi-lan JING

    2015-06-01

    Full Text Available Objective To explore the clinical efficacy of intra-aortic balloon pump (IABP as an auxiliary treatment of percutaneous coronary intervention (PCI in patients with coronary heart disease (CHD associated with chronic kidney disease. Methods One hundred and twenty CHD patients with concomitant chronic kidney disease and receiving PCI in our hospital from Jan. 2000 to Jul. 2014, and 123 simple CHD patients without renal dysfunction, who had undergone PCI with concomitant IABP for the cardiac pump failure, cardiogenic shock, acute left heart failure, unstable angina pectoris (UP which was not allayed by medical treatment, or acute myocardial infarction (AMI, were selected for observation of preoperative condition, in-hospital mortality and prognosis of patients in two groups. Results There was no statistically significant difference in general clinical data including gender, age, and concomitant hypertension and diabetes, and preoperative blood lipid, AST, D-dimer, APTT, and international normalized ratio (INR showed also no statistically significant difference before surgery between two groups of patients (P>0.05. The difference in proportion of AMI, the left main trunk and (or three-branches involvement was of no statistical significance (P>0.05, but there was significant difference in the incidence of previous myocardial infarction, TnT, CK-MB, Cr, BUN, stent number, IABP application time (P0.05 between the two groups. Logistic regression analysis revealed that diabetes and the number of stents were independent risk factors for in-hospital and long-term mortalities. Conclusions By means of the effective cardiac assistance of IABP, CHD patients with renal insufficiency have the same short and long term clinical prognosis as simple CHD patients without renal dysfunction who has undergone PCI. Diabetes and the number of stents are independent risk factors for in-hospital and 1-year mortality. DOI: 10.11855/j.issn.0577-7402.2015.04.03

  20. [Intraaortic balloon pumping( IABP) in Japan].

    Science.gov (United States)

    Ono, Tomoyuki; Tanoue, Yoshihisa; Tominaga, Ryuji

    2014-07-01

    The intraaortic balloon pumping (IABP) is the most widely used circulatory assist device. IABP increases coronary perfusion in diastolic phase by the inflation of the balloon in the descending aorta (diastolic augmentation) and reduces afterload in systolic phase by the deflation of the balloon( systolic unloading). IABP improves the hemodynamic condition of patients who fall into acute heart failure and/or cardiogenic shock. Six-type IABP system can be used in Japan. The IABP-SHOCK II trial shows that there is no significant difference in mortality between optimal medical treatment with IABP and without IABP in addition to early revascularization. Clinical backgrounds in Japan are different from those in IABP-SHOCK II trial, and the further prospective studies of IABP in Japan thus called for.

  1. Aortic valvuloplasty of calcific aortic stenosis with monofoil and trefoil balloon catheters: practical considerations

    NARCIS (Netherlands)

    S. Plante (Sylvain); M.J.B.M. van den Brand (Marcel); L.C.P. van Veen; C. di Mario (Carlo); C.E. Essed; K.J. Beatt (Kevin); P.W.J.C. Serruys (Patrick)

    1990-01-01

    textabstractIn order to evaluate the relation between balloon design (monofoil, trefoil) and valvular configuration, experimental aortic valvuloplasty was performed in four post-mortem hearts with calcific aortic stenosis of various morphology. The degree of obstruction of the aortic orifice was

  2. Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation

    Science.gov (United States)

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R.

    2015-01-01

    Abstract The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. PMID:25959284

  3. Impact of intra-aortic balloon pump on short-term clinical outcomes in ST-elevation myocardial infarction complicated by cardiogenic shock: A "real life" single center experience.

    Science.gov (United States)

    de la Espriella-Juan, R; Valls-Serral, A; Trejo-Velasco, B; Berenguer-Jofresa, A; Fabregat-Andrés, Ó; Perdomo-Londoño, D; Albiach-Montañana, C; Vilar-Herrero, J V; Sanmiguel-Cervera, D; Rumiz-Gonzalez, E; Morell-Cabedo, S

    2017-03-01

    To analyze the use and impact of the intra-aortic balloon pump (IABP) upon the 30-day mortality rate and short-term clinical outcome of non-selected patients with ST-elevation acute myocardial infarction (acute STEMI) complicated by cardiogenic shock (CS). A single-center retrospective case-control study was carried out. Coronary Care Unit. Data were collected from 825 consecutive patients with acute STEMI admitted to a Coronary Care Unit from January 2009 to August 2015. Seventy-three patients with CS upon admission subjected to emergency percutaneous coronary intervention (PCI) were finally included in the analysis and were stratified according to IABP use (44 patients receiving IABP). Cardiovascular history, hemodynamic situation upon admission, angiographic and procedural characteristics, and variables derived from admission to the Coronary Care Unit. Cumulative 30-day mortality was similar in the patients subjected to IABP and in those who received conventional medical therapy only (29.5% and 27.6%, respectively; HR with IABP 1.10, 95% CI 0.38-3.11; p=0.85). Similarly, no significant differences were found in terms of the short-term clinical outcome between the groups: time on mechanical ventilation, days to hemodynamic stabilization, vasoactive drug requirements and stay in the Coronary Care Unit. Poorer renal function (HR 3.9, 95% CI 1.4-10.6; p=0.008), known peripheral artery disease (HR 3.3, 95% CI 1.2-9.1; p=0.019) and a history of diabetes mellitus (HR 3.2, 95% CI 1.2-8.1; p=0.018) were the only variables independently associated to increased 30-day mortality. In our "real life" experience, IABP does not modify 30-day mortality or the short-term clinical outcome in patients presenting STEMI complicated with CS and subjected to emergency percutaneous coronary revascularization. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  4. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping designs have been developed to study the pump performance and capacity at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data shows that, the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon. PMID:24441792

  5. Pulmonary Venous Diastolic Flow Reversal and Flash Pulmonary Edema During Management of Ongoing Myocardial Ischemia with Intraaortic Balloon Pump.

    Science.gov (United States)

    Murray, Davoy; Peng, Yong G

    2015-10-15

    A 65-year-old man was admitted for acute coronary syndrome with depressed left ventricular function and moderate aortic regurgitation. He was managed with an intraaortic balloon pump for circulatory support before coronary artery bypass grafting and subsequently developed flash pulmonary edema with an associated rare finding of diastolic pulmonary venous flow reversal. In this report, we provide a review of intraaortic balloon pump use in current clinical practice and elaborate on the pathophysiology of an uncommon pulmonary venous flow pattern found in our patient.

  6. Measurements of Intra-Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation.

    Science.gov (United States)

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R; Khir, Ashraf W

    2015-08-01

    The intra-aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre-, intra-, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi-recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra-aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. Copyright © 2015 The Authors. Artificial Organs published by Wiley Periodicals, Inc. on behalf of International Center for

  7. Outcomes in patients with contained ruptures of the aortic annulus after transcatheter aortic valve implantation with balloon-expandable devices

    DEFF Research Database (Denmark)

    Breitbart, Philipp; Minners, Jan; Pache, Gregor

    2017-01-01

    ) at three centers in Germany and Denmark. CR were identified in 12 patients (1.2%, 80.7+5.0 years, STS-Score 4.1+1.4%). All 12 patients had received a balloon-expandable valve. In 3 patients periprocedural transesophageal echocardiography revealed findings suggestive of aortic dissection, an aortic...

  8. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Schuhbaeck, Annika, E-mail: annika.schuhbaeck@uk-erlangen.de [Department of Cardiology, University of Erlangen, Erlangen (Germany); Weingartner, Christina [Department of Cardiology, University of Gießen, Giessen (Germany); Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed [Department of Cardiology, University of Erlangen, Erlangen (Germany); Rixe, Johannes; Nef, Holger [Department of Cardiology, University of Gießen, Giessen (Germany); Schneider, Christian [Department of Radiology, University of Gießen, Giessen (Germany); Lell, Michael; Uder, Michael [Department of Radiology, University of Erlangen, Erlangen (Germany); Ensminger, Stephan [Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Ruhr-University Bochum, Bad Oeynhausen (Germany); Feyrer, Richard; Weyand, Michael [Department of Cardiothoracic Surgery, University of Erlangen, Erlangen (Germany); Achenbach, Stephan [Department of Cardiology, University of Erlangen, Erlangen (Germany)

    2015-07-15

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification.

  9. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    International Nuclear Information System (INIS)

    Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan

    2015-01-01

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification

  10. Variations in aortic pressure affect the mechanics of the intra-aortic balloon: an in vitro investigation.

    Science.gov (United States)

    Biglino, Giovanni; Kolyva, Christina; Whitehorne, Michael; Pepper, John R; Khir, Ashraf W

    2010-07-01

    This study aims to investigate the mechanics of the intra-aortic balloon (IAB) under different aortic pressure (P(ao)) and inclination (0-75 degrees). Pressure and flow were measured in an artificial aorta during IAB pumping with a frequency of 1:3. Volume displaced toward the "coronary arteries" during inflation (V(prox)) and "intra-aortic" pressure reduction during deflation (P(r)) were derived. IAB duration of inflation and deflation was determined with a high-speed camera visualization. When the aorta was horizontal, P(ao) raised from 45 mm Hg to 115 mm Hg, V(prox) reduced by 18% (25.0 +/- 1.0 mL vs. 30.4 +/- 1.9 mL) and P(r) increased by 117% (106.4 +/- 0.3 mm Hg vs. 48.9 +/- 0.6 mm Hg). When the aorta was inclined, at low P(ao) of 45 mm Hg, V(prox) was reduced by 30% from 0 degrees to 45 degrees (19.8 +/- 2.3 mL vs. 28.3 +/- 1.7 mL) and P(r) was reduced by 66% (16.5 +/- 0.1 mm Hg vs. 48.9 +/- 0.6 mm Hg). However, at high P(ao) of 115 mm Hg, V(prox) remained unchanged with increasing angle (20.0 +/- 1.0 mL) and P(r) was reduced by 24% (80.6 +/- 0.8 mm Hg vs. 106.4 +/- 0.3 mm Hg). Increasing P(ao) increased duration of inflation. At low P(ao), increasing angle resulted in increasing duration of inflation, but at high P(ao), increasing angle had the opposite effect. Duration of deflation generally decreased with P(ao) and increased with increasing angle. The IAB pump is affected by both P(ao) and angle, indicating that non-normotensive patients or patients in the semi-recumbent position might not receive the full benefits of IAB counterpulsation.

  11. Prospective Evaluation of the Correlation Between Torso Height and Aortic Anatomy in Respect of a Fluoroscopy Free Aortic Balloon Occlusion System

    Science.gov (United States)

    2014-06-01

    Prospective evaluation of the correlation between torso height and aortic anatomy in respect of a fluoroscopy free aortic balloon occlusion system...pubis) in the development of a fluoroscopy free balloon occlusion system for hemorrhage control. Methods. We conducted a prospective, observational...analysis in the development of a fluoroscopy free balloon occlusion system for torso hemorrhage control. Further study in a larger population of mixed

  12. Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty.

    Science.gov (United States)

    Campelo-Parada, Francisco; Nombela-Franco, Luis; Urena, Marina; Regueiro, Ander; Jiménez-Quevedo, Pilar; Del Trigo, María; Chamandi, Chekrallah; Rodríguez-Gabella, Tania; Auffret, Vincent; Abdul-Jawad Altisent, Omar; DeLarochellière, Robert; Paradis, Jean-Michel; Dumont, Eric; Philippon, François; Pérez-Castellano, Nicasio; Puri, Rishi; Macaya, Carlos; Rodés-Cabau, Josep

    2018-03-01

    Little is known about the timing of onset and outcome of conduction abnormalities (CA) following balloon-expandable transcatheter aortic valve implantation. The aim of this study was to examine the timing of CA and determine the impact of balloon aortic valvuloplasty (BAV) on the persistence of these abnormalities. A total of 347 patients were included. Of these, 75 had a continuous electrocardiogram recording and a 6-lead electrocardiogram at each step of the procedure. In the transcatheter aortic valve implantation population undergoing continuous electrocardiogram monitoring, new-onset left bundle branch block (LBBB) or third-degree atrioventricular block occurred in 48 (64%) and 16 (21.3%) patients, with 51.5% of CA occurring before valve implantation. Left bundle branch block persisted more frequently at hospital discharge (53.8 vs 22.7%; P=.028) and at 1-month follow-up (38.5 vs 13.6%; P=.054) when occurring before valve implantation. Balloon aortic valvuloplasty prior to valve implantation was used in 264 (76.1%) patients, and 78 (22.5%) had persistent LBBB or complete atrioventricular block requiring pacemaker implantation. Persistent LBBB or unresolved atrioventricular block at 1 month occurred more frequently in the BAV group (76.1 vs 47.6%; P=.021), and the use of BAV was associated with a lack of CA resolution (OR, 3.5; 95%CI, 1.17-10.43; P=.021). In patients undergoing a balloon-expandable transcatheter aortic valve implantation, more than half of CA occurred before valve implantation. Early occurrence of CA was associated with a higher rate of persistence at 1-month follow-up. The use of BAV was associated with an increased risk of CA persistence. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2009-06-01

    ão.OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning

  14. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    Science.gov (United States)

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  15. Fiber-optic intra-aortic balloon therapy and its role within cardiac surgery.

    Science.gov (United States)

    Yarham, G; Clements, A; Morris, C; Cumberland, T; Bryan, M; Oliver, M; Burrows, H; Mulholland, J

    2013-03-01

    The patient population has changed and the cardiothoracic team are now operating on patients with more co-morbidity. One of the significant aspects of this increased co-morbidity, which affects both short- and long-term outcomes, is compromised left ventricular function. Intra-aortic balloon pump (IABP) technology offers these patients and the cardiac team an easily accessible, cost-effective, mechanical assist device. Arterial pressure monitoring for IABP therapy: Fluid-filled transducers used to measure the aortic waveform can be unreliable and inconsistent. Fiber-optic manometers located in the very tip of the IAB catheters provide accurate and fast, high quality measurements. This, in turn, presents the opportunity for the hardware and algorithm to measure key markers on the arterial waveform and optimise left ventricular support. It also provides the potential for automatic in vivo calibration, further increasing the accuracy and quality of the IAB support. The effect of fiber-optic IABP therapy on clinical management: A dual centre prospective audit comparing fluid-filled versus fiber-optic arterial pressure monitoring showed a 96% reduction in IAB-related perfusion on-site call-outs (17 vs. 1, respectively) and a 94% reduction in sub-optimal timing (55/98 vs. 2/94, respectively). The improved timing algorithms utilise the pressure information received 50 msecs faster than with fluid-filled transducers, measuring key markers on the pressure waveform and adjusting inflation and deflation accurately on a beat per beat basis. Fiber-optic IAB technology and, specifically, these improved algorithms provide better beat per beat mechanical support. Given our evolving patient population, this technology will not only play an increased role, but will have a significant impact on cardiac surgery.

  16. 78 FR 79300 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems for Acute...

    Science.gov (United States)

    2013-12-30

    .... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems... of these devices into class II. List of Subjects in 21 CFR Part 870 Medical devices, Cardiovascular... Commissioner of Food and Drugs, 21 CFR part 870 is amended as follows: PART 870--CARDIOVASCULAR DEVICES 0 1...

  17. Stented balloon fenestration before entry repair using the frozen elephant trunk technique for chronic aortic dissection.

    Science.gov (United States)

    Uchida, Naomichi; Yamane, Yoshitaka; Furukawa, Tomokuni

    2018-02-01

    Endovascular fenestration on the abdominal aorta is effective for preventing visceral malperfusion in aortic dissection. We report a case of stented balloon fenestration before residual entry repair using the frozen elephant trunk technique for chronic aneurysmal dissection after ascending aortic replacement for DeBakey I aortic dissection. We recognized poor communication between the true lumen and false lumen in the abdominal aorta, and visceral perfusion depended almost entirely on the proximal large entry. Therefore, we scheduled catheter angioplasty on the small re-entry before upstream entry closure. After balloon angioplasty using a PTA catheter, a 10-mm × 4-cm self-expandable stent was deployed at the re-entry. We performed open surgery 5 days after angioplasty. Computed tomography after entry repair showed complete thrombosis of the false lumen on the descending aorta, and the celiac and superior mesenteric arteries were supplied via the abdominal re-entry stent. Stented balloon fenestration before entry repair using frozen elephant trunk with chronic aortic dissection was effective for preventing visceral malperfusion. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    International Nuclear Information System (INIS)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki; Ohishi, Sonomi; Nojiri, Yoko; Ogata, Hitoshi

    2001-01-01

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source

  19. The Inflammatory Sequelae of Aortic Balloon Occlusion in Hemorrhagic Shock

    Science.gov (United States)

    2014-04-13

    metabolic profile was significantly different. Clamp occlusion was associated with a significantly higher lactate burden and vasopressor requirement in...balloon occlusion. This was associated with a significant metabolic burden as measured by serum lactate; however, with suitable resuscitation, this...interleukin 10, reduces nuclear factor kB DNA binding, and improves short term survival in lethal endotoxemia . Crit Care Med 2004;32:801. [36] Manning JE

  20. Demonstration of ascending aorta in hypoplastic left heart syndrome with aortic atresia by balloon occlusion aortography

    International Nuclear Information System (INIS)

    Lo, R.N.S.; Leung, M.P.; Lau, K.C.

    1987-01-01

    Balloon occlusion angiography in the descending aorta produced clear retrograde visualization of the hypoplastic ascending aorta and related structures in eighteen neonates with aortic atresia. Transient bradycardia was the only complication observed. It is technically simpler than retrograde cannulation of the aorta via an arteriotomy and should be the method of choice when cardiac catheterization is required in patients with the hypoplastic left heart syndrome. (orig.)

  1. Balloon Dilatation and Stenting for Aortic Coarctation: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Salcher, Maximilian; Naci, Huseyin; Law, Tyler J; Kuehne, Titus; Schubert, Stephan; Kelm, Marcus

    2016-06-01

    There is no systematic assessment of available evidence on effectiveness and comparative effectiveness of balloon dilatation and stenting for aortic coarctation. We systematically searched 4 online databases to identify and select relevant studies of balloon dilatation and stenting for aortic coarctation based on a priori criteria (PROSPERO 2014:CRD42014014418). We quantitatively synthesized results for each intervention from single-arm studies and obtained pooled estimates for relative effectiveness from pairwise and network meta-analysis of comparative studies. Our primary analysis included 15 stenting (423 participants) and 12 balloon dilatation studies (361 participants), including patients ≥10 years of age. Post-treatment blood pressure gradient reduction to ≤20 and ≤10 mm Hg was achieved in 89.5% (95% confidence interval, 83.7-95.3) and 66.5% (44.1-88.9%) of patients undergoing balloon dilatation, and in 99.5% (97.5-100.0%) and 93.8% (88.5-99.1%) of patients undergoing stenting, respectively. Odds of achieving ≤20 mm Hg were lower with balloon dilatation as compared with stenting (odds ratio, 0.105 [0.010-0.886]). Thirty-day survival rates were comparable. Numerically more patients undergoing balloon dilatation experienced severe complications during admission (6.4% [2.6-10.2%]) compared with stenting (2.6% [0.5-4.7%]). This was supported by meta-analysis of head-to-head studies (odds ratio, 9.617 [2.654-34.845]) and network meta-analysis (odds ratio, 16.23, 95% credible interval: 4.27-62.77) in a secondary analysis in patients ≥1 month of age, including 57 stenting (3397 participants) and 62 balloon dilatation studies (4331 participants). Despite the limitations of the evidence base consisting predominantly of single-arm studies, our review indicates that stenting achieves superior immediate relief of a relevant pressure gradient compared with balloon dilatation. © 2016 American Heart Association, Inc.

  2. Ascending Aorta Stenting After Off-Pump Aortic Wrapping in Stanford A Retrograde Aortic Dissection.

    Science.gov (United States)

    Verscheure, Dorian; Ramadan, Ramzi; Azmoun, Alexandre; Guihaire, Julien; Angel, Claude; Brenot, Philippe; Deleuze, Philippe

    2017-08-01

    We report 4 cases of off-pump ascending aorta wrapping combined with ascending aorta stenting in retrograde Stanford A acute aortic dissection (SAAD). Since 2008, 18 patients have undergone wrapping of the ascending aorta at our institution. Four patients had a persistent circulating false lumen in the ascending aorta after wrapping, with a threat to the aortic root. We chose an endovascular approach with ascending aorta stenting. Follow-up computed tomography showed a reapplication of the intimal flap in the reinforced aorta. Ascending aorta stenting after aortic wrapping for retrograde SAAD is a safe and efficient technique to prevent proximal progression of the dissection. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Elective use of intra-aortic balloon pumping during Whipple's ...

    African Journals Online (AJOL)

    2012-07-27

    Jul 27, 2012 ... echocardiogram demonstrated diastolic dysfunction, a mild reduction in left ventricular function (ejection fraction. = 50%) and hypokinetic mid-distal interventricular septum and apex. A coronary angiogram was performed (Figure 1). The left main coronary artery showed a distal block of 60-70%. The left ...

  4. Two-in-one aortic valve sizing and valvuloplasty conductance balloon catheter.

    Science.gov (United States)

    Svendsen, Mark C; Sinha, Anjan K; Berwick, Zachary C; Combs, William; Teague, Shawn D; Lefevre, Thierry; Babaliaros, Vasilis; Kassab, Ghassan

    2015-07-01

    Inaccurate aortic valve sizing and selection is linked to paravalvular leakage in transcatheter aortic valve replacement (TAVR). Here, a novel sizing valvuloplasty conductance balloon (SVCB) catheter is shown to be accurate, reproducible, unbiased, and provides real-time tool for aortic valve sizing that fits within the standard valvuloplasty procedure. The SVCB catheter is a valvuloplasty device that uses real-time electrical conductance measurements based on Ohm's Law to size the balloon opposed against the aortic valve at any given inflation pressure. Accuracy and repeatability of the SVCB catheter was performed on the bench in phantoms of known dimension and ex vivo in three domestic swine aortic annuli with comparison to computed tomography (CT) and dilator measurements. Procedural workflow and safety was demonstrated in vivo in three additional domestic swine. SVCB catheter measurements had negligible bias or error for bench accuracy considered as the gold standard (Bias: -0.11 ± 0.26 mm; Error: 1.2%), but greater disagreement in ex vivo versus dilators (Bias: -0.3 ± 1.1 mm; Error: 4.5%), and ex vivo versus CT (Bias: -1.0 ± 1.6 mm; Error: 8.7%). The dilator versus CT accuracy showed similar agreement (Bias: -0.9 ± 1.5 mm; Error: 7.3%). Repeatability was excellent on the bench (Bias: 0.02 ± 0.12 mm; Error: 0.5%) and ex vivo (Bias: -0.4 ± 0.9 mm; Error: 4.6%). In animal studies, the device fit well within the procedural workflow with no adverse events or complications. Due to the clinical relevance of this accurate, repeatable, unbiased, and real-time sizing measurement, the SVCB catheter may provide a useful tool prior to TAVR. These findings merit a future human study. © 2015 Wiley Periodicals, Inc.

  5. Uso rutinario del balón de contra-pulsación aórtica preoperatorio en pacientes con enfermedad del tronco común izquierdo sometidos a cirugía de revascularización coronaria Routine use of preoperative intra-aortic balloon pump counterpulsation (IABP implantation in patients with left main coronary artery disease undergoing coronary revascularization surgery

    Directory of Open Access Journals (Sweden)

    Andrés Fernández

    2008-08-01

    cuidados intensivos se infectaron 6,5% de los pacientes con balón y 3% del grupo sin balón (p=0,49 y hubo sepsis en 4,3% del grupo con balón y en ninguno del grupo restante (p=0,23. La letalidad en la unidad de cuidados intensivos se presentó en 2,2% del grupo de balón y en 3% del otro grupo (p=0,06. No ocurrió mortalidad intrahospitalaria fuera de la unidad de cuidados intensivos como tampoco mortalidad a 30 días después del alta. El tiempo de estancia en la misma unidad fue de 4,13 días en el grupo de balón y 2,7 días en el grupo sin balón, sin diferencia estadísticamente significativa entre éstos (p=0,154. El tiempo de ventilación mecánica en el grupo de balón fue de 1,96 días mientras que en el otro grupo fue de 1,18 días sin diferencia estadísticamente significativa (p=0,288. Con respecto a los pacientes que recibieron balón de contra pulsación intra-aórtico, el promedio de uso de balón fue de 1,32 días y no se presentaron complicaciones vasculares relacionadas con su uso. Conclusiones: este estudio sugiere que con el uso rutinario del balón de contra pulsación aórtica previo a la cirugía electiva de revascularización coronaria en pacientes cuya única indicación sea la lesión severa del tronco común izquierdo, no se obtiene beneficio en cuanto a letalidad y tiempo de estancia en la unidad de cuidados intensivos, ni con respecto al tiempo de ventilación mecánica. Tampoco se encontró mayor riesgo de desarrollar infección o sepsis en la misma unidad.Background: Left main coronary artery disease as the only criterion for intra-aortic balloon counterpulsation implantation is an indication which evidence is limited to experts’ recommendations; therefore, studies that may give a higher level of evidence are required. For this reason, we developed in our institution a study that evaluated the experience in the use of IABP in patients with left main coronary artery disease undergoing coronary revascularization surgery. Objective

  6. Immediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting

    Directory of Open Access Journals (Sweden)

    Hasan Mottaghi Moghadam

    2017-12-01

    Full Text Available Background Aortic Coarcatation (CoA is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs. Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA. We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty with our without stenting was performed for 53 patients with native or Re-coarcatation angioplasty (39 balloon angioplasty alone, and 14 balloon and stenting. Pressure gradient across the CoA segment was measured initially by Echo and pre, and Post procedure. Echocardiography was also used for follow up assessment during 24 hours, one and 6 months afterward. Results Among 53 patients, 52.8% were male. There were 98.2% native and 3.8% Re-CoA. The mean age of patients was 8.65 ± 8.37 years, and the mean weight was 25.82±20.73 kg. The mean pressure gradient acrossthe CoA site before angioplasty was 24.88±12.32, and post procedure gradient was 4.77±6.42 (p

  7. A Novel Fluoroscopy-free, Resuscitative Endovascular Aortic Balloon Occlusion System in a Model of Hemorrhagic Shock

    Science.gov (United States)

    2013-07-01

    A novel fluoroscopy -free, resuscitative endovascular aortic balloon occlusion system in a model of hemorrhagic shock Daniel J. Scott, MD, Jonathan L...hemorrhagic shock. However, emergent use of REBOA is limited by existing technology, which requires large sheath arterial access and fluoroscopy - guided...balloon positioning. The objectives of this study were to describe a new, fluoroscopy -free REBOA system and to compare its efficacy to existing technology

  8. Aortic balloon occlusion for controlling intraoperative hemorrhage in patients with placenta previa increta/percreta.

    Science.gov (United States)

    Wang, Ying-Lan; Su, Fang-Ming; Zhang, Hai-Ying; Wang, Fang; Zhe, Rui-Lian; Shen, Xin-Ying

    2017-11-01

    To investigate whether abdominal aortic balloon occlusion (ABO) effectively reduces intraoperative hemorrhage in patents with placenta previa increta/increta. Forty-three women were diagnosed as placenta previa increta/percreta by ultrasound and MRI. These patients' assessments were taken by their chief physician, and they were under necessity of previous cesarean section as confirmed by the committee of experts during consultation. There was no significant difference in disease risk rating between them in whole process. Although our department provided a more appropriate method, 10 of 43 patients chose intraoperative aortic balloon occlusion (IABO). Other 33 patients who refused that suggestion were considered as control group. Fully informed consents were obtained from all patients in this study group. The intraoperative blood loss, blood transfusion, rate of hysterectomy and complications of mothers and fetus of IABO group and control group were analyzed. The median intraoperative blood loss was 1000 ml in the IABO group compared with 2000 ml in the control group (p  0.05). No IABO-related complications were observed in the mother and fetus. IABO is an effective and safe method to control intraoperative blood loss and blood transfusion in patients with placenta previa increta/percreta.

  9. Remodeling of the aortic neck with a balloon-expandable stent graft in patients with complicated neck morphology.

    Science.gov (United States)

    Kolvenbach, Ralf; Pinter, Laslo; Cagiannos, Catherine; Veith, Frank J

    2008-01-01

    Graft migration and other device-related problems are more frequent in abdominal aortic aneurysm (AAA) patients with a complicated neck. We wanted to evaluate the performance of a balloon-expandable stent graft in these cases. Complicated aortic neck morphology was defined as a combination of short (45 degrees) necks with or without circumferential thrombus. Severe aortic angulation was defined as less than 120 degrees. During a 24-month period, 18 consecutive patients with complicated neck anatomy were treated with the Vascular Innovations (VI)-Datascope balloon-expandable endograft. In two patients, a balloon-expandable cuff was implanted to remodel the neck prior to insertion of a bifurcated endograft (Excluder, W.L. Gore & Associates, Flagstaff, AZ). Demographic, procedural, and outcome data were collected prospectively and retrospectively analyzed. All patients had preoperative computed tomographic (CT) angiography to determine aortic neck angulation and were followed with duplex ultrasonography and CT every 3 and 6 months postoperatively to assess aortic neck and sac dilatation, as well as device migration. The VI-Datascope graft consists of an aortounifemoral polytetrafluoroethylene (PTFE) graft sutured to a proximal balloon-expandable stent. The length of the graft is 40 cm; thus, the distal end of the graft always protrudes through the ipsilateral arteriotomy and can be cut to an appropriate length for each patient. The covered portion of the graft was deployed just below the level of the lowest renal artery. The proximal bare metal stent was deployed in the suprarenal area. An endoluminal hand-sewn anastomosis was performed between the aortounifemoral limb and the distal external iliac or the common femoral arteries. An occluder device was placed in the contralateral common iliac artery to prevent retrograde perfusion of the aneurysm. A femorofemoral 8 mm Dacron graft bypass was then performed to establish flow to the contralateral extremity and pelvis

  10. Protective effects of indomethacin and dexamethasone in a goat model with intrauterine balloon aortic valvuloplasty.

    Science.gov (United States)

    Zhou, Kaiyu; Wu, Gang; Li, Yifei; Zhao, Liang; Zhou, Rong; Zhu, Qi; Huang, Xupei; Mu, Dezhi; Hua, Yimin

    2012-08-13

    Intrauterine balloon aortic valvuloplasty (IUBAV) has been used for critical aortic stenosis. However, it is necessary to determine the fetal impairments such as preterm birth after this approach and to find a way to prevent or reduce them. In the present study, we evaluated the therapeutic value of indomethacin (IDM) and dexamethasone (DXS) on reducing the preterm birth rate in experimental goats after IUBAV. Our results indicated that the administration of IDM/DXS significantly reduced the rate of premature birth. IDM/DXS treatment led to preservation of myocardial ultrastructure with less damage, and amelioration of the fetal and placental circulation. Furthermore, we found that norepinephrine (NE) level was positively associated with the degree of myocardial damage. IDM/DXS administration led to a significant decrease of operation-induced increase of NE levels, which may be associated with the protective effects of IDM/DXS. Lastly, we found that the administration of IDM/DXS did not induce the risk of ductus arteriosus closure or slow down fetal growth. Our results indicate that IDM/DXS promotes a better gestational outcome at least partially by reducing stress response during and after the operation of IUBAV in the goat model. IDM/DXS may be a useful application in human patients during IUBAV intervention.

  11. Protective effects of indomethacin and dexamethasone in a goat model with intrauterine balloon aortic valvuloplasty

    Directory of Open Access Journals (Sweden)

    Zhou Kaiyu

    2012-08-01

    Full Text Available Abstract Background Intrauterine balloon aortic valvuloplasty (IUBAV has been used for critical aortic stenosis. However, it is necessary to determine the fetal impairments such as preterm birth after this approach and to find a way to prevent or reduce them. Methods In the present study, we evaluated the therapeutic value of indomethacin (IDM and dexamethasone (DXS on reducing the preterm birth rate in experimental goats after IUBAV. Results Our results indicated that the administration of IDM/DXS significantly reduced the rate of premature birth. IDM/DXS treatment led to preservation of myocardial ultrastructure with less damage, and amelioration of the fetal and placental circulation. Furthermore, we found that norepinephrine (NE level was positively associated with the degree of myocardial damage. IDM/DXS administration led to a significant decrease of operation-induced increase of NE levels, which may be associated with the protective effects of IDM/DXS. Lastly, we found that the administration of IDM/DXS did not induce the risk of ductus arteriosus closure or slow down fetal growth. Conclusions Our results indicate that IDM/DXS promotes a better gestational outcome at least partially by reducing stress response during and after the operation of IUBAV in the goat model. IDM/DXS may be a useful application in human patients during IUBAV intervention.

  12. Intracoronary thrombolysis and intraaortic balloon counterpulsation for the emergency treatment of probable coronary embolism after repair of an acute ascending aortic dissection.

    Science.gov (United States)

    Mentzelopoulos, S D; Kokotsakis, J N; Romana, C N; Karamichali, E A

    2001-07-01

    This report shows that if diffuse coronary thromboembolism is encountered during ascending aortic dissection-repair, the option of combining single-bolus, intracoronary thrombolysis with intraaortic balloon counterpulsation should be considered.

  13. Caesarean section combined with temporary aortic balloon occlusion followed by uterine artery embolisation for the management of placenta accreta

    International Nuclear Information System (INIS)

    Duan, X.-H.; Wang, Y.-L.; Han, X.-W.; Chen, Z.-M.; Chu, Q.-J.; Wang, L.; Hai, D.-D.

    2015-01-01

    Aim: To determine the efficacy and safety of caesarean section combined with temporary aortic balloon occlusion followed by uterine artery embolisation (UAE) for the treatment of patients with placenta accreta. Materials and methods: This retrospective study involved 42 patients with placenta accreta. All patients underwent caesarean section combined with temporary aortic balloon occlusion followed by UAE through the right femoral approach. Results: All patients were confirmed to have placenta praevia and accreta, including five patients with placenta percreta, at the time of delivery. The technical success rate of the combined treatment was 97.6% (41/42). Forty-one patients underwent successful caesarean section with conservation of the uterus. Hysterectomy was required in one (3.1%) patient. The amount of blood loss and blood transfusion, and the operation time were was 586 ± 355 ml, 422 ± 83 ml and 65.5 ± 10.6 minutes, respectively. The mean postoperative hospital stay, occlusion time and fetal radiation dose were 5.5 ± 2.6 days, 22.4 ± 7.2 minutes and 4.2 ± 2.9 mGy, respectively. There were no significant changes before and 7 days after the endovascular procedure in creatinine levels (56.8 ± 13.8 μmol/l versus 63.4 ± 16.7 μmol/l, p = 0.09) or urea nitrogen (6.3 ± 2.5 μmol/l versus 7.4 ± 3.8 μmol/l, p = 0.17). There were no access-site complications after the endovascular procedure and no complications related to the intervention during follow-up. Conclusion: Temporary aortic balloon occlusion followed by UAE can effectively control postpartum haemorrhage during placental dissection, and reduce transfusion requirements, hysterectomy rate, and operation time in patients with placenta accreta. -- Highlights: •Aortic balloon occlusion can overcome the collateral flow from other arteries. •UAE can effectively manage secondary postpartum haemorrhage. •The aortic balloon can rapidly and easily insert. •The mean

  14. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    International Nuclear Information System (INIS)

    Fetterly, K; Mathew, V

    2014-01-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors

  15. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    Energy Technology Data Exchange (ETDEWEB)

    Fetterly, K; Mathew, V [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

  16. Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair

    OpenAIRE

    G?rer, Onur; Haberal, Ismail; Ozsoy, Deniz

    2013-01-01

    Patient: Male, 74 Final Diagnosis: Abdominal aortic aneurysm (AAA) Symptoms: Palpable abdominal mass Medication: ? Clinical Procedure: Abdominal aortic aneurysm repair Specialty: Surgery Objective: Rare disease Background: Coronary artery disease is common in elderly patients with abdominal aortic aneurysms. Here we report a case of the combination of surgical repair for abdominal aortic aneurysm and off-pump and minimally invasive coronary artery bypass surgery. Case Report: A 74-year-old ma...

  17. Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3.

    Science.gov (United States)

    Kaneko, Hidehiro; Hoelschermann, Frank; Tambor, Grit; Yoon, Sung-Han; Neuss, Michael; Butter, Christian

    2017-02-15

    Paravalvular regurgitation (PVR) is a common and serious complication after transcatheter aortic valve implantation (TAVI). New-generation balloon-expandable SAPIEN 3 has an outer sealing skirt to minimize PVR. However, the predictors of PVR after SAPIEN 3 transcatheter heart valve (THV) implantation have not been well investigated. We sought to clarify the determinants of PVR after TAVI using SAPIEN 3 with quantitative multidetector computed tomography (MDCT) assessment. This study analyzed 281 patients with severe symptomatic aortic stenosis who underwent TAVI using SAPIEN 3. Quantitative assessment of aortic root dimensions and calcium volume for leaflet, annulus, and left ventricular outflow tract were retrospectively performed with MDCT. MDCT nominal area oversizing was calculated using the following formula: % oversizing = (THV nominal area/MDCT derived annular area - 1) × 100. Logistic regression analysis was performed to determine the predictors of PVR greater than or equal to mild. PVR greater than or equal to mild was observed in 19% (53 of 281). Quantity and asymmetry of aortic valve calcium of annulus, left ventricular outflow tract, and leaflet were associated with higher incidence of PVR greater than or equal to mild, except leaflet asymmetry. Lower percentage of THV oversizing was also associated with PVR. Multivariable logistic regression analysis showed that larger calcification volume of annulus and lower percentage of THV oversizing were independent predictors of PVR greater than or equal to mild. These results suggest that prosthesis/annulus incongruence and aortic annulus calcification predicted PVR greater than or equal to mild after TAVI using SAPIEN 3. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. The Effect of Infrarenal Aortic Balloon Occlusion on Weaning from Supraceliac Aortic Balloon Occlusion in a Porcine Model (Sus scrofa) of Hemorrhagic Shock

    Science.gov (United States)

    2017-06-15

    all animals , and continued for six hours. Half of the animals were randomly assigned to Zone-3 REBOA for an additional 45 minutes following Zone-1...concentration or resuscitation requirements.Conclusion: In an animal model of hemorrhagic shock and Zone-1 REBOA, subsequent Zone-3 aortic occlusion did not add

  19. Tackling the Issue of High Postoperative Pacemaker Implantation Rates in Sutureless Aortic Valve Replacement: Should Balloon Inflation be Removed from the Implantation Method of the Perceval Prosthesis?

    Science.gov (United States)

    Charles Blouin, Mathieu; Bouhout, Ismail; Demers, Philippe; Carrier, Michel; Perrault, Louis; Lamarche, Yoan; El-Hamamsy, Ismail; Bouchard, Denis

    2017-05-01

    Sutureless aortic valve replacement (AVR) is an emerging alternative to standard AVR in elderly and high-risk patients. This procedure is associated with a high rate of postoperative permanent pacemaker implantation (PPI). The study aim was to assess the impact on the rate of PPI of implanting the Perceval prosthesis without using balloon inflation. A total of 159 patients who underwent sutureless AVR using the Perceval prosthesis was included. Balloon inflation was used in 132 patients (Balloon group) and not used in the remaining 27 (No-Balloon group). Clinical, echocardiographic and electrocardiographic outcomes were assessed. There was no significant difference in PPI rate between the two groups (26% for Balloon group versus 22% in No-Balloon group; p = 0.700). Balloon inflation had no significant impact on the incidence of paravalvular leaks (p = 0.839), or on the need to return to cardiopulmonary bypass (CPB) intraoperatively due to paravalvular leak or unsatisfactory deployment (p >0.999). Mean and peak transaortic pressure gradients were similar between the two groups (p = 0.417 and p = 0.522, respectively). Cross-clamp and CPB times were shorter in the No-Balloon group (49.6 ± 15.9 min versus 61.1 ± 25.6 min and 64.1 ± 26.3 min versus 79.6 ± 35.4 min, respectively; p = 0.027 and p = 0.012, respectively). The two groups had similar postoperative PPI rates. Implanting the Perceval prosthesis without balloon inflation is safe and had no impact on paravalvular leaks, intraoperative complications or hemodynamic results. Reductions in aortic cross-clamp time and CPB time were observed when the balloon was not used.

  20. Intraoperative aortic balloon occlusion in patients with placenta previa and/or placenta accreta: a retrospective study.

    Science.gov (United States)

    Luo, Fangyuan; Xie, Lan; Xie, Ping; Liu, Siwei; Zhu, Yue

    2017-04-01

    To introduce the primary experience of using aortic balloon catheters during cesarean section for placenta previa and/or placenta accreta. From January 2013 to May 2015, 43 patients who were preoperatively diagnosed with major placenta previa and/or placenta accreta and who underwent prophylactic aortic catheterization before caesarean section (CS) were included in the study. We analyzed the clinical data of the study population. Surgery- and catheterization-related complications were also reported. Major placenta previa or placenta accreta was surgically confirmed in 42 patients, 28 of whom had both conditions. The mean patient age was 32.3 ± 5.5 years, whereas the median gestational age at delivery was 260 (range, 153-280) days. Twenty-nine (67.4%) patients had previously undergone CS, and 13 (30%) patients had undergone emergency surgery for antenatal hemorrhage. The median estimated blood loss during surgery was 500 (range, 100-3,000) mL, and the median duration of occlusion was 20 (range, 5-32) minutes. Hysterectomy was performed in five (11.6%) patients and uterine artery embolization in two (4.6%) patients. Two patients with placenta percreta experienced surgery-related complications, and two patients required hospital readmission. No major catheterization-related complications were observed. Forty-two live births were recorded, and the Apgar score of the infants at 5 minutes was > 7. Intraoperative aortic balloon occlusion is a relatively safe method for treating placenta previa and/or placenta accreta during scheduled and emergency CS and might be helpful to prevent hysterectomy and embolization in women wishing to preserve fertility. Copyright © 2017. Published by Elsevier B.V.

  1. Does the timing of treatment with intra-aortic balloon counterpulsation in cardiogenic shock due to ST-elevation myocardial infarction affect survival?

    Science.gov (United States)

    Bergh, Niklas; Angerås, Oskar; Albertsson, Per; Dworeck, Christian; Matejka, Göran; Haraldsson, Inger; Ioanes, Dan; Libungan, Berglind; Odenstedt, Jacob; Petursson, Petur; Ridderstråle, Wilhelm; Råmunddal, Truls; Omerovic, Elmir

    2014-06-01

    Intra-aortic balloon pump (IABP) counterpulsation and primary percutaneous coronary intervention (PCI) are standard treatment modalities in cardiogenic shock (CS) complicating acute myocardial infarction. The aim of this study was to investigate the impact of the timing of IABP treatment start in relation to PCI procedure. Data were obtained from the SCAAR registry (Swedish Coronary Angiography and Angioplasty Registry) about 139 consecutive patients with CS due to ST-elevation myocardial infarction (STEMI) who received IABP treatment. The patients were hospitalized at Sahlgrenska University Hospital, Gothenburg, during 2004-2008. The cohort was divided into the two groups: group (A) in whom IABP treatment started before start of PCI (n = 72) and group (B) in whom IABP treatment started after PCI treatment (n = 67). The primary endpoint was 30-day mortality. Propensity score (PS) adjusted Cox proportional hazards regression was used to analyze predictors of 30-day mortality. Mean age was 66.5 ± 12 and 28% were women. All patients have received IABP treatment 30 min before or 30 min after primary PCI. 63% had diabetes and 28% had hypertension. 16% were active tobacco smokers. The mortality rate at 30 days was 38%. IABP treatment commenced before or after PCI was not an independent predictor of mortality (P = 0.72). In this non-randomized trial the treatment with insertion of IABP before primary PCI in patients with CS due to STEMI is not associated with a more favorable outcome as compared with IABP started after primary PCI.

  2. Assessment of the "long sheath" technique for percutaneous aortic balloon valvuloplasty

    NARCIS (Netherlands)

    S. Plante (Sylvain); K.J. Beatt (Kevin); M.J.B.M. van den Brand (Marcel); C. di Mario (Carlo); B. Meier (Bernard); P.W.J.C. Serruys (Patrick)

    1990-01-01

    textabstractA 100 cm-long 16.5 F valvuloplasty catheter introducer was assessed as an adjunct for percutaneous transluminal aortic valvuloplasty (PTAV) via the femoral artery in 31 patients with severe aortic stenosis. Observed improvements in peak systolic gradient (81.6 +/- 29.9 mm Hg vs. 35.5 +/-

  3. Hemostasis with emergently modified application of intra‐aortic balloon occlusion in a patient with impending cardiac arrest following blunt proximal thigh amputation

    Science.gov (United States)

    Uchida, Kotaro; Homma, Hiroshi; Yukioka, Tetsuo; Nagai, Noriko; Mishima, Shiro; Ohta, Shoichi

    2014-01-01

    Case A 30‐year‐old woman had her left thigh run over by a train. We tried to compress the left femoral area to control the arterial bleeding, but bleeding continued from the stump and injured soft tissue. The application of a tourniquet bandage also failed because of the limited remaining thigh. She developed impending cardiac arrest. As the left femoral arterial pulsation was still palpable, we inserted an intra‐aortic balloon occlusion catheter percutaneously. The hemorrhage from the stump region decreased rapidly. She was transferred to an operating room to carry out surgical hemostasis, and it was confirmed with deflation of the balloon in the common iliac artery. Outcome There was no complication of the skin or soft tissue at the surgical site caused by impaired circulation, and her consciousness fully recovered. Conclusion We report the successful control of bleeding by the emergently modified application of intra‐aortic balloon occlusion in the left common iliac artery. PMID:29123695

  4. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.

    Science.gov (United States)

    Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo

    2018-05-15

    Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair.

    Science.gov (United States)

    Gürer, Onur; Haberal, Ismail; Ozsoy, Deniz

    2013-01-01

    Male, 74 FINAL DIAGNOSIS: Abdominal aortic aneurysm (AAA) Symptoms: Palpable abdominal mass Medication: - Clinical Procedure: Abdominal aortic aneurysm repair Specialty: Surgery. Rare disease. Coronary artery disease is common in elderly patients with abdominal aortic aneurysms. Here we report a case of the combination of surgical repair for abdominal aortic aneurysm and off-pump and minimally invasive coronary artery bypass surgery. A 74-year-old man who presented at our clinic with chest pain was diagnosed with an abdominal aortic aneurysm. His medical history included right coronary artery stenting. Physical examination revealed a pulsatile abdominal mass on the left side and palpable peripheral pulses. Computed tomography scans showed an infrarenal abdominal aneurysm with a 61-mm enlargement. Coronary angiography revealed 80% stenosis in the stent within the right coronary artery and 20% stenosis in the left main coronary artery. The patient underwent elective coronary artery bypass grafting and abdominal aortic aneurysm repair. Abdominal aortic aneurysm repair and transdiaphragmatic off-pump and minimal invasive coronary artery bypass grafting with right gastroepiploic artery were performed simultaneously in a single surgery. We report this case to emphasize the safety and effectiveness of transdiaphragmatic off-pump and minimally invasive coronary artery bypass surgery with abdominal aortic aneurysm repair. This combined approach shortens hospital stay and decreases cost.

  7. 78 FR 36702 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems (IABP) for...

    Science.gov (United States)

    2013-06-19

    ... Investigators, ``Intraaortic Balloon Support for Myocardial Infarction With Cardiogenic Shock.'' New England Journal of Medicine, vol. 367, pp. 1287-1296, 2012. 3. Anderson, R.D., M.E. Ohman, and D.R. Holmes for the... complications of heart failure, a preamendments class III device, into class II (special controls) based on new...

  8. Transient left ventricular apical ballooning in a patient with bicuspid aortic valve created a left ventricular thrombus leading to acute renal infarction.

    Science.gov (United States)

    Sasaki, Norihito; Kinugawa, Toru; Yamawaki, Masahiro; Furuse, Yoshiyuki; Shimoyama, Masaki; Ogino, Kazuhide; Igawa, Osamu; Hisatome, Ichiro; Shigemasa, Chiaki

    2004-11-01

    A 44-year-old woman had tako-tsubo-like ventricular dysfunction with chest pain and ST segment elevation on the ECG. Echocardiography revealed a bicuspid aortic valve with moderate to severe aortic regurgitation. She developed mild heart failure during the clinical course, but the medication (furosemide, enalapril, and asprin) had to be stopped because of skin eruptions. Four weeks after ceasing the antiplatelet agent, she was re-admitted with acute renal infarction. Enhanced chest computed tomography revealed a filling defect in the left ventricle and echocardiography showed a high echogenic mass in the left ventricular apical wall. These findings strongly suggested that the renal infarction was caused by an embolism derived from a left ventricular thrombus that formed during the clinical course of the transient left ventricular apical ballooning. Anticoagulation therapy with urokinase and warfarin successfully lysed the thrombus. Left ventricular thrombus should be considered a complication of transient left ventricular apical ballooning, especially in patients with organic heart disease.

  9. Impact of routine crossover balloon occlusion technique on access-related vascular complications following transfemoral transcatheter aortic valve replacement.

    Science.gov (United States)

    Zaman, Sarah; Gooley, Robert; Cheng, Victoria; McCormick, Liam; Meredith, Ian T

    2016-08-01

    To determine the impact of incorporating routine crossover balloon occlusion technique (CBOT) for vascular access closure following transcatheter aortic valve replacement (TAVR) on major access-site-related complications. Vascular complications are associated with increased mortality following TAVR. The CBOT involves passage of a balloon catheter from the contralateral femoral artery to enable controlled closure of large-sheath access-sites. Consecutive patients who underwent transfemoral TAVR as part of three clinical trials were prospectively recruited. Patients who had routine CBOT (CBOT group, n = 55) were compared to preceding patients who did not undergo CBOT (control group, n = 43). The primary endpoint was 30-day occurrence of access-site-related Valve Academic Research Consortium (VARC)-2 defined major vascular and/or bleeding complications. CBOT was successfully performed in 96% with 2% occurrence of a minor CBOT-related complication. At 30-days access-site-related major vascular and/or bleeding occurred in 5.5% and 18.6% of the CBOT and control group, respectively (P = 0.042). This consisted of VARC-2 major vascular events in 3.6% and 16.3% (P = 0.036) and VARC-2 major/life-threatening bleeding events in 5.5% and 14.0% (P = 0.137) of the CBOT and control group, respectively. Transfusion of ≥2 units of packed red blood cells were required in 10.9% and 30.2% of the CBOT and control group, respectively (P = 0.016). There was no significant difference in contrast load, procedure time, and kidney injury between the two groups. Routine CBOT for TAVR access-site closure has a high success rate and is associated with a significant reduction in VARC-2 major vascular and bleeding complications compared to TAVR performed without CBOT. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve.

    Science.gov (United States)

    Xuan, Yue; Krishnan, Kapil; Ye, Jian; Dvir, Danny; Guccione, Julius M; Ge, Liang; Tseng, Elaine E

    2017-05-01

    Transcatheter aortic valve replacement is established therapy for high-risk and inoperable patients with severe aortic stenosis, but questions remain regarding long-term durability. Valve design influences durability. Increased leaflet stresses in surgical bioprostheses have been correlated with degeneration; however, transcatheter valve leaflet stresses are unknown. From 2007 to 2014, a majority of US patients received first-generation balloon-expandable transcatheter valves. Our goal was to determine stent and leaflet stresses in this valve design using finite element analyses. A 26-mm Sapien Transcatheter Heart Valve (Edwards Lifesciences, Inc, Irvine, Calif) underwent high-resolution microcomputed tomography scanning to develop precise 3-dimensional geometry of the leaflets, the stent, and the polyethylene terephthalate elements. The stent was modeled using 3-dimensional elements and the leaflets were modeled using shell elements. Stent material properties were based on stainless steel, whereas those for leaflets were obtained from surgical bioprostheses. Noncylindrical Sapien valve geometry was also simulated. Pressure loading to 80 mm Hg and 120 mm Hg was performed using ABAQUS finite element software (Dassault Systèmes, Waltham, Mass). At 80 mm Hg, maximum principal stresses on Sapien leaflets were 1.31 megaspascals (MPa). Peak leaflet stress was observed at commissural tips where leaflets connected to the stent. Maximum principal stresses for the stent were 188.91 MPa and located at stent tips where leaflet commissures were attached. Noncylindrical geometry increased peak principal leaflet stresses by 16%. Using exact geometry from high-resolution scans, the 26-mm Sapien Transcatheter Heart Valve showed that peak stresses for both stent and leaflets were present at commissural tips where leaflets were attached. These regions would be prone to leaflet degeneration. Understanding stresses in first-generation transcatheter valves allows comparison to

  11. Long-Term Follow-Up of Percutaneous Balloon Angioplasty in Adult Aortic Coarctation

    International Nuclear Information System (INIS)

    Paddon, Alex J.; Nicholson, Anthony A.; Ettles, Duncan F.; Travis, Simon J.; Dyet, John F.

    2000-01-01

    Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). The average number of antihypertensive drugs required per patient decreased from 0.56 to 0.31 (p = 0.234). No significant residual stenoses or restenoses were seen at MRI. Small but clinically insignificant residual pressure gradients were recorded in all patients using Doppler echocardiography. Complications included one transient ischemic attack at 5 days, one external iliac dissection requiring stent insertion, and a further patient who developed a false aneurysm close to the coarctation site at 12 months which subsequently required surgical excision.Conclusion: PTA of adult coarctation is safe and effective in the long term. Although primary stenting has recently been advocated in the treatment of this condition, our results suggest that PTA remains the treatment of choice

  12. Unexpected Radiation-Induced Aortic Wall Thickening Requiring Composite Graft Technique during Off-Pump Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Paola Redaelli

    2017-01-01

    Full Text Available Mediastinal radiation is commonly used to treat Hodgkin’s and non-Hodgkin’s lymphoma, lung and breast cancer. Cardiac complications after radiation therapy are well described, although rare. A large spectrum of injuries can occur, causing long term morbidity among survivors. We describe a case of post-actinic ascending aortic wall thickening that prevented saphenous vein proximal anastomosis and was successfully managed with aortic no-touch off-pump coronary artery bypass grafting (OPCAB, 25 years after radiation therapy for Hodgkin’s lymphoma.

  13. The Effect Of Supraphysiologic Blood Pressure on Traumatic Brain Injury and Proximal Tissue Beds During Resuscitative Balloon Occlusion of the Aorta and Variable Aortic Control in a Porcine Model (Sus scrofa) of Polytrauma.

    Science.gov (United States)

    2017-04-27

    Supraphysiologic Blood Pressure On Traumatic Brain Injury And Proximal Tissue Beds During Resuscitative Balloon Occlusion Of The Aorta And Variable Aortic...combined effects of increased proximal mean arterial pressure (pMAP), carotid blood flow (Qcarotid), and intracranial pressure (ICP) from REBOA would...Mandatory) The Effect of REBOA, Partial Aortic Occlusion and Aggressive Blood Transfusion on Traumatic Brain Injury in a Swine Polytrauma Model

  14. Passive aortic counterpulsation: biomechanical rationale and bench validation.

    Science.gov (United States)

    Corazza, Ivan; Bianchini, David; Marcelli, Emanuela; Cercenelli, Laura; Zannoli, Romano

    2014-05-07

    Aortic counterpulsation (IABP) consists in an ECG-controlled forced deflation and inflation of a balloon positioned in the aorta. The device is designed to decrease the ventricular afterload during systole and to increase the coronary driving pressure during diastole. In biomechanical terms, the IABP improves the mechanical matching between the pump and the load, facilitating the transfer of ventricular energy. This paper describes a completely passive aortic counterpulsation solution, with an intra-aortic balloon without a pumping system, designed to improve the mechanical matching between the ventricle and the artery at very low cost and complexity. The only requirement is an external reservoir to amplify the balloon pulsations due to physiologic arterial pressure pulse. Using a cardiovascular simulator and changing the reservoir pressure, a systolic not negligible (7.8ml) gas volume exchange between the intra-aortic balloon and the reservoir was measured. The same cardiovascular simulator was used to demonstrate an increase in stroke volume in three conditions of progressive ventricular failure, by detecting a change in systolic and diastolic arterial pressures and stroke volume (SV). The maximal arterial pressure always decreased and the diastolic pressure increased. The SV increased up to 7.8%, demonstrating an arterial elastance reduction and better ventricular-aortic mechanical matching and energy transfer. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement.

    Science.gov (United States)

    Condado, Jose F; Corrigan, Frank E; Lerakis, Stamatios; Parastatidis, Ioannis; Stillman, Arthur E; Binongo, Jose N; Stewart, James; Mavromatis, Kreton; Devireddy, Chandan; Leshnower, Bradley; Guyton, Robert; Forcillo, Jessica; Patel, Ateet; Thourani, Vinod H; Block, Peter C; Babaliaros, Vasilis

    2017-10-01

    Though several anatomical characteristics have been reported separately as risk factors for paravalvular leak (PVL) and landing zone (LZ) complications after transcatheter aortic valve replacement (TAVR), multivariate risk models are needed. Patients that underwent balloon-expandable TAVR with multidetector cardiac computed tomography (MDCT) sizing were studied. MDCT images were analyzed and the association between anatomical factors and ≥mild PVL, ≥moderate PVL, and LZ complications (annular rupture, requirement of new permanent pacemaker, and coronary obstruction) was determined, and subsequently competing predictive models were developed and validated. A total of 316 consecutive TAVR patients were included. Median age was 82.0 years (74.0-87.0) and STS score was 8.3% (5.4-10.9). Factors associated with ≥mild PVL included TAVR with Sapien/Sapien XT vs. Sapien 3 (OR = 2.50, 95% CI = 1.24-5.07), LVOT nontubularity (OR = 1.02, 95% CI = 1.01-1.04), LZ calcification (OR = 1.01, 95% CI = 1.00-1.01), and low cover index (OR = 0.94, 95% CI = 0.91-0.96). Factors associated with LZ complications included LZ calcification (OR = 1.01, 95% CI 1.00-1.01), leaflet asymmetry (OR = 1.01, 95% CI 1.01-1.02), and cover index (OR = 1.09, 95% CI 1.03-1.14). Predictive models for ≥mild PVL (AUC = 0.71, 95% CI = 0.66-0.77), ≥moderate PVL (AUC = 0.75, 95% CI = 0.65-0.84), and LZ complications (AUC = 0.77, 95% CI = 0.67-0.87) were created using procedural details and anatomical data from the MDCT. Clinical variables were not included as they were poorly correlated with the occurrence of PVL and LZ complications. For each outcome, the area under the curve (AUC) of the multivariate model was superior to the model consisting only of individual factors. A model using procedural/anatomical characteristics derived from MDCT predicts ≥mild PVL, ≥moderate PVL, and LZ complications post-TAVR. Incorporation of

  16. Underexpansion and Ad Hoc Post-dilation in Selected Patients Undergoing Balloon-Expandable Transcatheter Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Barbanti, Marco; Leipsic, Jonathon; Binder, Ronald

    2014-01-01

    To assess the clinical outcomes and hemodynamic performance associated with a strategy of underexpanding balloon-expandable THVs when excessive oversizing is a concern.......To assess the clinical outcomes and hemodynamic performance associated with a strategy of underexpanding balloon-expandable THVs when excessive oversizing is a concern....

  17. Thoracic endovascular aortic repair and off-pump coronary artery bypass grafting after renal transplantation: a case report.

    Science.gov (United States)

    Yanase, Yohsuke; Muraki, Satoshi; Koyanagi, Tetsuya; Watanabe, Noriyasu; Kurimoto, Yoshihiko

    2011-01-01

    Twelve years after receiving a renal transplant, a 50-year-old woman developed asthmatic symptoms. Chest CT revealed a descending thoracic aortic aneurysm. She had undergone percutaneous coronary intervention to treat the left anterior descending artery 10 years earlier. Coronary artery angiography revealed restenosis of the left anterior descending artery (99%, #6 in-stent). Because cardiopulmonary bypass may cause problems for transplanted kidney, we performed off-pump coronary artery bypass grafting (left internal thoracic artery to left anterior descending artery) and thoracic endovascular graft placement to treat the aortic aneurysm. Considering that the artery of the transplanted kidney was attached to the right iliac artery, and then the left common femoral artery was selected as the access root for GORE TAG(®) endografts (34 × 200 and 34 × 150 mm) (stentgrafts were deployed for the descending aortic artery). Postoperative angiography showed a patent bypass graft. Postoperative CT confirmed the absence of endoleaks. The postoperative course was uneventful, and she was discharged without complications. Ischemic heart disease and descending thoracic aortic aneurysm in recipients of kidney transplants can be treated using off-pump coronary bypass grafting and thoracic endovascular graft placement. The transplanted kidney was protected without using cardiopulmonary bypass (CPB).

  18. Is there a role for upper-extremity intra-aortic balloon counterpulsation as a bridge-to-recovery or a bridge-to-transplant in the treatment of end-stage heart failure?

    Science.gov (United States)

    Nwaejike, Nnamdi; Son, Andre Y; Milano, Carmelo A; Daneshmand, Mani A

    2017-10-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: Is there a role for upper-extremity intra-aortic balloon pump counterpulsation (UE-IABP) in the treatment of end-stage heart failure? Altogether 230 papers were found using the reported search, of which 6 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Of the 163 bridge-to-transplantation (BTT) patients, 141 (86.5%) were successfully transplanted and of the 9 bridge-to-recovery (BTR) patients, 6 (66.7%) were successfully weaned from the device. Length of support ranged from 3 to 152 days, and the most frequent complications were device malfunction or migration necessitating exchange or repositioning, occurring at a collective rate of 37.3%. UE-IABP is a minimally invasive and cost-effective strategy that provides haemodynamic support while preserving both the mediastinum and the functional status in BTR and BTT patients who may not tolerate more invasive modes of mechanical circulatory support. We conclude that UE-IABP can be used as a bridge-to-recovery (BTR) or transplant (BTT) in patients with end-stage heart failure. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. 12. Percutaneous balloon angioplasty for critical aortic coarctation in newborns and infants: Is it still a valid option?

    Directory of Open Access Journals (Sweden)

    Shehla Jadoon

    2015-10-01

    Conclusions: Surgical repair for native neonatal and infantile coarctation is a preferred choice of treatment but it can be challenging in critically sick patients. However, balloon dilation remains a safe and effective temporary palliation for the critically sick patients. Despite of high incidence of restenosis, some patients do not need for mid-term further intervention.

  20. Percutaneous Balloon Angioplasty for Severe Native Aortic Coarctation in Young Infants Less Than 6 Months: Medium- to Long-term Follow-up

    Directory of Open Access Journals (Sweden)

    Lan He

    2015-01-01

    Full Text Available Background: Although balloon angioplasty (BA has been performed for more than 20 years, its use as a treatment for native coarctation of the aorta (CoA during childhood, especially in young infants, remains controversial. This study aimed to assess the effects and potential role of percutaneous transcatheter BA for native CoA as an alternative therapy to surgical repair in young infants. Methods: The 37 patients aged from 6 days to 6 months with severe CoA in congestive heart failure or circulatory shock were admitted for BA. Patient′s weight ranged from 2.4 to 6.1 kg. All 37 patients were experiencing cardiac dysfunction, and eight patients were in cardiac shock with severe metabolic acidosis. Eleven patients had an isolated CoA, whereas the others had a CoA associated with other cardiac malformations. Cardiac catheterization and aortic angiography were performed under general anesthesia with intubation. Transfemoral arterial approaches were used for the BA. The size of the balloon ranged from 3 mm × 20 mm to 8 mm × 20 mm, and a coronary artery balloon catheter was preferred over a regular peripheral vascular balloon catheter. Results: The femoral artery was successfully punctured in all but one patient, with that patient undergoing a carotid artery puncture . The systolic peak pressure gradient (PG across the coarctation was 41.0 ± 16.0 mmHg (range 13-76 mmHg. The mean diameter of the narrowest coarctation site was 1.7 ± 0.6 mm (range 0.5-2.8 mm. All patients had successful dilation; the PG significantly decreased to 13.0 ± 11.0 mmHg (range 0-40 mmHg, and the diameter of coarctation significantly improved to 3.8 ± 0.9 mm (range 2.5-5.3 mm. No intraoperative complications occurred for any patients. However, in one case that underwent a carotid artery puncture, a giant aneurysm formed at the puncture site and required surgical repair. The following observations were made during the follow-up period from 6-month to 7-year: (1 The PG

  1. Percutaneous Balloon Angioplasty for Severe Native Aortic Coarctation in Young Infants Less Than 6 Months: Medium- to Long-term Follow-up

    Science.gov (United States)

    He, Lan; Liu, Fang; Wu, Lin; Qi, Chun-Hua; Zhang, Li-Feng; Huang, Guo-Ying

    2015-01-01

    Background: Although balloon angioplasty (BA) has been performed for more than 20 years, its use as a treatment for native coarctation of the aorta (CoA) during childhood, especially in young infants, remains controversial. This study aimed to assess the effects and potential role of percutaneous transcatheter BA for native CoA as an alternative therapy to surgical repair in young infants. Methods: The 37 patients aged from 6 days to 6 months with severe CoA in congestive heart failure or circulatory shock were admitted for BA. Patient's weight ranged from 2.4 to 6.1 kg. All 37 patients were experiencing cardiac dysfunction, and eight patients were in cardiac shock with severe metabolic acidosis. Eleven patients had an isolated CoA, whereas the others had a CoA associated with other cardiac malformations. Cardiac catheterization and aortic angiography were performed under general anesthesia with intubation. Transfemoral arterial approaches were used for the BA. The size of the balloon ranged from 3 mm × 20 mm to 8 mm × 20 mm, and a coronary artery balloon catheter was preferred over a regular peripheral vascular balloon catheter. Results: The femoral artery was successfully punctured in all but one patient, with that patient undergoing a carotid artery puncture. The systolic peak pressure gradient (PG) across the coarctation was 41.0 ± 16.0 mmHg (range 13–76 mmHg). The mean diameter of the narrowest coarctation site was 1.7 ± 0.6 mm (range 0.5–2.8 mm). All patients had successful dilation; the PG significantly decreased to 13.0 ± 11.0 mmHg (range 0–40 mmHg), and the diameter of coarctation significantly improved to 3.8 ± 0.9 mm (range 2.5–5.3 mm). No intraoperative complications occurred for any patients. However, in one case that underwent a carotid artery puncture, a giant aneurysm formed at the puncture site and required surgical repair. The following observations were made during the follow-up period from 6-month to 7-year: (1) The PG across the

  2. Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition.

    Science.gov (United States)

    Eltchaninoff, Hélène; Durand, Eric; Avinée, Guillaume; Tron, Christophe; Litzler, Pierre-Yves; Bauer, Fabrice; Dacher, Jean-Nicolas; Werhlin, Camille; Bouhzam, Najime; Bettinger, Nicolas; Candolfi, Pascal; Cribier, Alain

    2018-03-30

    Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.

  3. Anesthetic management of cesarean section in cases of placenta accreta, with versus without abdominal aortic balloon occlusion: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Chu, Qinjun; Shen, Dan; He, Long; Wang, Hongwei; Zhao, Xianlan; Chen, Zhimin; Wang, Yanli; Zhang, Wei

    2017-05-26

    Placenta accreta (PA), a severe complication during delivery, is closely linked with massive hemorrhage which could endanger the lives of both mother and baby. Moreover, the incidence of PA has increased dramatically with the increasing rate of cesarean deliveries in the past few decades. Therefore, studies evaluating the effects of different perioperative managements based on different modalities in the treatment of PA are necessary. Among the numerous treatment measures, prophylactic abdominal aortic balloon occlusion (AABO) in combination with cesarean section for PA seems to be more advantageous than others. However, up to now, all studies on AABO were almost retrospective. Current evidence is insufficient to recommend for or against routinely using the AABO technology for control intraoperative hemorrhage in patients with PA. Thus, we hope to carry out a prospective, randomized controlled trial (RCT) study to confirm the effectiveness of the AABO technology in patients with PA. This trial is an investigator-initiated, prospective RCT that will test the superiority of AABO in combination with cesarean section compared to the traditional hysterectomy following cesarean section for parturients with PA. A total of 170 parturients with PA undergoing cesarean section will be randomized to receive either AABO in combination with cesarean section or the traditional hysterectomy following cesarean section. The primary outcome is estimated blood loss. The most important secondary outcome is the occurrence of cesarean hysterectomy during delivery; others include blood transfusion volume, operating time, neonate's Apgar scores (collected at 1, 5 and 10 min), length of stay in intensive care unit, total hospital stay, and balloon occlusion-relative data. This prospective trial will test the superiority of AABO in combination with cesarean section compared to the traditional hysterectomy following cesarean section for parturients with PA. It may provide strong evidence

  4. The influence of pump rotation speed on hemodynamics and myocardial oxygen metabolism in left ventricular assist device support with aortic valve regurgitation.

    Science.gov (United States)

    Iizuka, Kei; Nishinaka, Tomohiro; Takewa, Yoshiaki; Yamazaki, Kenji; Tatsumi, Eisuke

    2017-09-01

    Aortic valve regurgitation (AR) is a serious complication under left ventricular assist device (LVAD) support. AR causes LVAD-left ventricular (LV) recirculation, which makes it difficult to continue LVAD support. However, the hemodynamics and myocardial oxygen metabolism of LVAD support with AR have not been clarified, especially, how pump rotation speed influences them. An animal model of LVAD with AR was newly developed, and how pump rotation speed influences hemodynamics and myocardial oxygen metabolism was examined in acute animal experiments. Five goats (55 ± 9.3 kg) underwent centrifugal type LVAD, EVAHEART implantation. The AR model was established by placing a vena cava filter in the aortic valve. Hemodynamic values and the myocardial oxygen consumption, delivery, and oxygen extraction ratio (O 2 ER) were evaluated with changing pump rotation speeds with or without AR (AR+, AR-). AR+ was defined as Sellers classification 3 or greater. AR was successfully induced in five goats. Diastolic aortic pressure was significantly lower in AR+ than AR- (p = 0.026). Central venous pressure, mean left atrial pressure, and diastolic left ventricular pressure were significantly higher in AR+ than AR- (p = 0.010, 0.047, and 0.0083, respectively). Although systemic flow did not improve with increasing pump rotation speed, LVAD pump flow increased over systemic flow in AR+, which meant increasing pump rotation speed increased LVAD-LV recirculation and did not contribute to effective systemic circulation. O 2 ER in AR- decreased with increasing pump rotation speed, but O 2 ER in AR+ was hard to decrease. The O 2 ER in AR+ correlated positively with the flow rate of LVAD-LV recirculation (p = 0.012). AR caused LVAD-LV recirculation that interfered with the cardiac assistance of LVAD support and made it ineffective to manage with high pump rotation speed.

  5. Aspirin Versus Aspirin Plus Clopidogrel as Antithrombotic Treatment Following Transcatheter Aortic Valve Replacement With a Balloon-Expandable Valve: The ARTE (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation) Randomized Clinical Trial.

    Science.gov (United States)

    Rodés-Cabau, Josep; Masson, Jean-Bernard; Welsh, Robert C; Garcia Del Blanco, Bruno; Pelletier, Marc; Webb, John G; Al-Qoofi, Faisal; Généreux, Philippe; Maluenda, Gabriel; Thoenes, Martin; Paradis, Jean-Michel; Chamandi, Chekrallah; Serra, Vicenç; Dumont, Eric; Côté, Mélanie

    2017-07-10

    The aim of this study was to compare aspirin plus clopidogrel with aspirin alone as antithrombotic treatment following transcatheter aortic valve replacement (TAVR) for the prevention of ischemic events, bleeding events, and death. Few data exist on the optimal antithrombotic therapy following TAVR. This was a randomized controlled trial comparing aspirin (80 to 100 mg/day) plus clopidogrel (75 mg/day) (dual antiplatelet therapy [DAPT]) versus aspirin alone (single-antiplatelet therapy [SAPT]) in patients undergoing TAVR with a balloon-expandable valve. The primary endpoint was the occurrence of death, myocardial infarction (MI), stroke or transient ischemic attack, or major or life-threatening bleeding (according to Valve Academic Research Consortium 2 definitions) within the 3 months following the procedure. The trial was prematurely stopped after the inclusion of 74% of the planned study population. A total of 222 patients were included, 111 allocated to DAPT and 111 to SAPT. The composite of death, MI, stroke or transient ischemic attack, or major or life-threatening bleeding tended to occur more frequently in the DAPT group (15.3% vs. 7.2%, p = 0.065). There were no differences between groups in the occurrence of death (DAPT, 6.3%; SAPT, 3.6%; p = 0.37), MI (DAPT, 3.6%; SAT, 0.9%; p = 0.18), or stroke or transient ischemic attack (DAPT, 2.7%; SAPT, 0.9%; p = 0.31) at 3 months. DAPT was associated with a higher rate of major or life-threatening bleeding events (10.8% vs. 3.6% in the SAPT group, p = 0.038). There were no differences between groups in valve hemodynamic status post-TAVR. This small trial showed that SAPT (vs. DAPT) tended to reduce the occurrence of major adverse events following TAVR. SAPT reduced the risk for major or life-threatening events while not increasing the risk for MI or stroke. Larger studies are needed to confirm these results. (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation: The ARTE

  6. Emergency Abdominal Aortic Aneurysm Repair in a Patient with Failing Heart: Axillofemoral Bypass Using a Centrifugal Pump Combined with Levosimendan for Inotropic Support

    Science.gov (United States)

    Michalek, Pavel; Sebesta, Pavel; Stern, Michael

    2011-01-01

    We describe the case of an 83-year-old patient requiring repair of a large symptomatic abdominal aortic aneurysm (AAA). The patient was known to have coronary artery disease (CAD) with symptoms and signs of significant myocardial dysfunction, left-heart failure, and severe aortic insufficiency. The procedure was performed with the help of both mechanical and pharmacological circulatory support. Distal perfusion was provided by an axillofemoral bypass with a centrifugal pump, with dobutamine and levosimendan administered as pharmacological inotropic support. The patient's hemodynamic status was monitored with continuous cardiac output monitoring and transesophageal echocardiography. No serious circulatory complications were recorded during the perioperative and postoperative periods. This paper suggests a potential novel approach to combined circulatory support in patients with heart failure, scheduled for open abdominal aortic aneurysm repair. PMID:22937463

  7. Emergency Abdominal Aortic Aneurysm Repair in a Patient with Failing Heart: Axillofemoral Bypass Using a Centrifugal Pump Combined with Levosimendan for Inotropic Support

    Directory of Open Access Journals (Sweden)

    Pavel Michalek

    2011-01-01

    Full Text Available We describe the case of an 83-year-old patient requiring repair of a large symptomatic abdominal aortic aneurysm (AAA. The patient was known to have coronary artery disease (CAD with symptoms and signs of significant myocardial dysfunction, left-heart failure, and severe aortic insufficiency. The procedure was performed with the help of both mechanical and pharmacological circulatory support. Distal perfusion was provided by an axillofemoral bypass with a centrifugal pump, with dobutamine and levosimendan administered as pharmacological inotropic support. The patient's hemodynamic status was monitored with continuous cardiac output monitoring and transesophageal echocardiography. No serious circulatory complications were recorded during the perioperative and postoperative periods. This paper suggests a potential novel approach to combined circulatory support in patients with heart failure, scheduled for open abdominal aortic aneurysm repair.

  8. The self-expanding Symetis Acurate does not increase cerebral microembolic load when compared to the balloon-expandable Edwards Sapien prosthesis: a transcranial Doppler study in patients undergoing transapical aortic valve implantation.

    Directory of Open Access Journals (Sweden)

    Gabor Erdoes

    Full Text Available OBJECTIVES: The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS during transapical transcatheter aortic valve implantation (TA-TAVI, by comparing the Symetis Acurate TA (SA with the balloon-expandable Edwards Sapien XT (ES system. BACKGROUND: Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD as HITS, or not is not clear. METHODS: Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7% displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. RESULTS: No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16. With both devices, HITS peaked during prosthesis deployment (PD, whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: < 0.001 or post-implantation PI (SA: p = 0.007; ES: < 0.001. PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients. CONCLUSIONS: Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

  9. The self-expanding Symetis Acurate does not increase cerebral microembolic load when compared to the balloon-expandable Edwards Sapien prosthesis: a transcranial Doppler study in patients undergoing transapical aortic valve implantation.

    Science.gov (United States)

    Erdoes, Gabor; Huber, Christoph; Basciani, Reto; Stortecky, Stefan; Windecker, Stephan; Wenaweser, Peter; Carrel, Thierry; Eberle, Balthasar

    2014-01-01

    The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: < 0.001) or post-implantation PI (SA: p = 0.007; ES: < 0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

  10. Systematic Design of a Magnetically Levitated Brushless DC Motor for a Reversible Rotary Intra-Aortic Blood Pump.

    Science.gov (United States)

    Wang, Yaxin; Logan, Thomas G; Smith, P Alex; Hsu, Po-Lin; Cohn, William E; Xu, Liping; McMahon, Richard A

    2017-10-01

    The IntraVAD is a miniature intra-aortic ventricular assist device (VAD) designed to work in series with the compromised left ventricle. A reverse-rotation control (RRc) mode has been developed to increase myocardial perfusion and reduce ventricular volume. The RRc mode includes forward rotation in systole and reverse rotation in diastole, which requires the IntraVAD to periodically reverse its rotational direction in synchrony with the cardiac cycle. This periodic reversal leads to changes in pressure force over the impeller, which makes the entire system less stable. To eliminate the mechanical wear of a contact bearing and provide active control over the axial position of the rotor, a miniature magnetically levitated bearing (i.e., the PM-Coil module) composed of two concentric permanent magnetic (PM) rings and a pair of coils-one on each side-was proposed to provide passive radial and active axial rotor stabilization. In the early design stage, the numerical finite element method (FEM) was used to optimize the geometry of the brushless DC (BLDC) motor and the maglev module, but constructing a new model each time certain design parameters were adjusted required substantial computation time. Because the design criteria for the module had to be modified to account for the magnetic force produced by the motor and for the hemodynamic changes associated with pump operation, a simplified analytic expression was derived for the expected magnetic forces. Suitable bearings could then be designed capable of overcoming these forces without repeating the complicated FEM simulation for the motor. Using this method at the initial design stage can inform the design of the miniature maglev BLDC motor for the proposed pulsatile axial-flow VAD. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  11. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  12. Successful endovascular aneurysm repair for abdominal aortic aneurysm in a patient with severe coronary artery disease undergoing off-pump coronary artery bypass grafting.

    Science.gov (United States)

    Kim, Sun Min; Cho, Jae Yeong; Kim, Ju Han; Park, Keun-Ho; Sim, Doo Sun; Hong, Young Joon; Ahn, Youngkeun; Jeong, Myung Ho

    2014-04-01

    It is well known that patients with abdominal aortic aneurysm (AAA) often have concomitant coronary artery disease (CAD). In cases of AAA with severe CAD requiring coronary artery bypass grafting (CABG), two therapeutic strategies regarding the timing of CABG can be considered: staged or simultaneous operations. However, the ideal treatment of patients with large AAA and critical CAD remains controversial. We experienced a case of successful endovascular aneurysm repair after off-pump CABG in a 70-year-old patient who had a huge AAA and critical CAD.

  13. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  14. Bicuspid aortic valve

    Science.gov (United States)

    ... females. A BAV often exists in babies with coarctation of the aorta (narrowing of the aorta). BAV is also seen ... to view the blood vessels of the heart Treatment ... to the heart and into the narrow opening of the aortic valve. A balloon attached to the end of ...

  15. Impact of underfilling and overfilling in balloon-expandable transcatheter aortic valve implantation assessed by multidetector computed tomography: Insights from the Optimized CathEter vAlvular iNtervention (OCEAN-TAVI) registry.

    Science.gov (United States)

    Yashima, Fumiaki; Yamamoto, Masanori; Watanabe, Yusuke; Takagi, Kensuke; Yamada, Yoshitake; Inohara, Taku; Yanagisawa, Ryo; Tanaka, Makoto; Arai, Takahide; Shimizu, Hideyuki; Jinzaki, Masahiro; Kozuma, Ken; Fukuda, Keiichi; Suzuki, Takahiko; Hayashida, Kentaro

    2016-11-01

    Underfilling or overfilling of balloon-expandable transcatheter heart valves (THVs) during transcatheter aortic valve implantation (TAVI) is commonly used to improve conformity to small or calcified annuli in order to avoid serious complications. However, little is known about this technique. This study assessed the effects of underfilling and overfilling of THVs. Data from 213 consecutive TAVI patients treated with balloon-expandable THVs in 4 Japanese centers between October 2013 and December 2014 were prospectively analyzed; 23-mm and 26-mm THVs were implanted in 96 cases (56 underfilling, 22 nominal filling, and 18 overfilling) and 38 cases (23 underfilling and 15 nominal filling), respectively. Pre/postprocedural multidetector computed tomography (MDCT) and echocardiographic data were compared. MDCT revealed that the minimum area of the underfilled 23-mm THVs was significantly decreased compared to that of nominal filled and overfilled THVs (308.3 SD 26.1 vs. 333.9 SD 14.7 vs. 347.8 SD 21.3mm(2), respectively, p<0.0001); analogous results were demonstrated for underfilled 26-mm THVs compared to nominal filled THVs (386.2 SD 34.6 vs. 423.6 SD 17.3mm(2), respectively, p=0.0004). The postprocedural transvalvular gradient of underfilled 23-mm THVs was significantly higher than that of nominal filled and overfilled THVs, while there were no differences for 26-mm THVs. Underfilling or overfilling of THVs is safe and feasible, conforming to the original annulus and covering a continuous range of annular sizes with limited THV size options. However, care should be taken when underfilling 23-mm THVs due to the potential for increased transvalvular gradient. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. A comparison of Selective Aortic Arch Perfusion and Resuscitative Endovascular Balloon Occlusion of the Aorta for the management of hemorrhage-induced traumatic cardiac arrest: A translational model in large swine.

    Directory of Open Access Journals (Sweden)

    Ed B G Barnard

    2017-07-01

    Full Text Available Survival rates remain low after hemorrhage-induced traumatic cardiac arrest (TCA. Noncompressible torso hemorrhage (NCTH is a major cause of potentially survivable trauma death. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA at the thoracic aorta (Zone 1 can limit subdiaphragmatic blood loss and allow for IV fluid resuscitation when intrinsic cardiac activity is still present. Selective Aortic Arch Perfusion (SAAP combines thoracic aortic balloon hemorrhage control with intra-aortic oxygenated perfusion to achieve return of spontaneous circulation (ROSC when cardiac arrest has occurred.Male Yorkshire Landrace cross swine (80.0 ± 6.0 kg underwent anesthesia, instrumentation for monitoring, and splenectomy. TCA was induced by laparoscopic liver lobe resection combined with arterial catheter blood withdrawal to achieve a sustained systolic blood pressure <10 mmHg, cardiac arrest. After 3 min of arrest, swine were allocated to one of three interventions: (1 REBOA plus 4 units of IV fresh whole blood (FWB, (2 SAAP with oxygenated lactated Ringer's (LR, 1,600 mL/2 min, or (3 SAAP with oxygenated FWB 1,600 mL/2 min. Primary endpoint was survival to the end of 60 min of resuscitation, a simulated prehospital phase. Thirty animals were allocated to 3 groups (10 per group-5 protocol exclusions resulted in a total of 35 animals being used. Baseline measurements and time to cardiac arrest were not different amongst groups. ROSC was achieved in 0/10 (0%, 95% CI 0.00-30.9 REBOA, 6/10 (60%, 95% CI 26.2-87.8 SAAP-LR and 10/10 (100%, 95% CI 69.2-100.0 SAAP-FWB animals, p < 0.001. Survival to end of simulated 60-minute prehospital resuscitation was 0/10 (0%, 95% CI 0.00-30.9 for REBOA, 1/10 (10%, 95% CI 0.25-44.5 for SAAP-LR and 9/10 (90%, 95% CI 55.5-99.7 for SAAP-FWB, p < 0.001. Total FWB infusion volume was similar for REBOA (2,452 ± 0 mL and SAAP-FWB (2,250 ± 594 mL. This study was undertaken in laboratory conditions, and as such may have

  17. [Simultaneous endovascular aortic aneurysm repair and coronary artery bypass grafting in a patient with abdominal aortic aneurysm and left main trunk lesion].

    Science.gov (United States)

    Nakao, Yoshihisa; Mitsuoka, Hiroshi; Masuda, Mikio; Shintani, Tsunehiro; Higashi, Shigeki

    2010-10-01

    To patients with severe coronary artery disease (CAD) and expanding large abdominal aortic aneurysm (AAA), simultaneous coronary artery bypass grafting (CABG) and AAA repair has been recommended. A 68-year-old woman had a CAD and an AAA 71 mm in diameter which was enlarging. Coronary angiography showed severe stenoses in the left main trunk (LMT), the left anterior descending artery and the circumflex artery. On-pump beating CABG and AAA repair with endovascular aneurysm repair (EVAR) were performed simultaneously, because intraaortic balloon pumping (IABP) might be needed due to severe stenoses of LMT. Just after EAVR, on-pump beating CABG was performed. The patient was discharged 15 days after the operation. It was suggested that a simultaneous operation of CABG and EVAR might be safe and effective for high risk patients with CAD and AAA.

  18. [Anesthetic Management of a Patient Complicated with Marfan Syndrome and Suffering from Stanford Type A Aortic Dissection during Pregnancy].

    Science.gov (United States)

    Uozaki, Nako; Mizuno, Kaori; Shiraishi, Yoshito; Doi, Matsuyuki; Sato, Shigehito

    2015-04-01

    We report a case of a 36-year-old woman at 34 weeks of gestation complicated with Marfan syndrome who underwent Bentall type aortic replacement surgery due to Stanford type A aortic dissection after undergoing caesarean section. Since this patient exhibited severe hypotension before coming to the operating room, it was very difficult to determine whether the cardiac surgery or caesarean section should be performed first. In this case, the caesarean section was performed first, followed by Bentall's surgery. Although intra-aortic balloon pumping and percutaneous cardiopulmonary support were required after weaning from the cardiopulmonary bypass, she was discharged on post-operative day (POD) 40 and the baby was discharged on POD 60, without signs of cerebral palsy. Unfortunately, this patient died on POD 57, due to heart failure. We discuss how to determine the priority of surgeries for patients who require emergency surgery for cardiovascular disease during pregnancy.

  19. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    Science.gov (United States)

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon

  20. Influence of cardiogenic shock with or without the use of intra-aortic balloon pump on mortality in patients with ST-segment elevation myocardial infarction

    Directory of Open Access Journals (Sweden)

    Jesper Khedri Jensen

    2015-03-01

    Conclusion: Patients with STEMI and cardiogenic shock had substantial short- and long-term mortality that may be improved with IABP implantation. More studies on use of IABP in such patients are warranted.

  1. Efficacy of Intra-aortic Balloon Pump before versus after Primary Percutaneous Coronary Intervention in Patients with Cardiogenic Shock from ST-elevation Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Lin Yuan

    2016-01-01

    Conclusions: Early IABP insertion before primary PCI is associated with improved myocardial perfusion although DBT increases. IABP support before PCI does not confer a 12-month clinical benefit when used for STEMI with CS.

  2. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  3. Aortic dissection

    Science.gov (United States)

    ... made in the chest or abdomen. Endovascular aortic repair. This surgery is done without any major surgical ... needed. If the heart arteries are involved, a coronary bypass is also performed. Outlook ... aneurysm - dissecting; Chest pain - aortic dissection; Thoracic aortic aneurysm - ...

  4. In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump.

    Science.gov (United States)

    Herreros, Jesús; Ubilla, Matías; Berjano, Enrique J; Vila-Nuñez, Juan E; Páramo, José A; Sola, Josu; Mercé, Salvador

    2010-02-01

    The aim of this study was to assess platelet dysfunction and damage to organs after extracorporeal circulation using a pump based on a new method that adds a pulsatile flow to the continuous flow provided by a centrifugal pump. The continuous component of the total flow (2-3 L/min) is created by a Bio-Pump centrifugal pump, while the pulsatile component is created by the pulsating of an inner membrane pneumatically controlled by an intra-aortic counterpulsation balloon console (systolic volume of 37.5 mL in an asynchronous way with a frequency of 60 bpm). Six pigs were subjected to a partial cardiopulmonary bypass lasting 180 min and were sacrificed 60 min after extracorporeal circulation was suspended. The hematological study included the measurement of hematocrit, hemoglobin, leukocytes, and platelet function. The new pump did not significantly alter either platelet count or platelet function. In contrast, hematocrit and hemoglobin were significantly reduced during extracorporeal circulation (approximately 5% P = 0.011, and 2 g/dL P = 0.01, respectively). The leukocyte count during extracorporeal circulation showed a tendency to decrease, but this was not significant. In general, the short-term use of the new pump (4 h) did not cause any serious morphological damage to the heart, lung, kidney, or liver. The results suggest that the hemodynamic performance of the new pump is similar to a conventional centrifugal pump and could therefore be appropriate for use in extracorporeal circulation.

  5. Two stage hybrid approach for complex aortic coarctation repair

    Directory of Open Access Journals (Sweden)

    Crockett James

    2009-02-01

    Full Text Available Abstract Background Management of an adult patient with aortic coarctation and an associated cardiac pathology poses a great surgical challenge since there are no standard guidelines for the therapy of such complex pathology. Debate exists not only on which lesion should be corrected first, but also upon the type and timing of the procedure. Surgery can be one- or two-staged. Both of these strategies are accomplice with elevate morbidity and mortality. Case report In the face of such an extended surgical approach, balloon dilatation seems preferable for treatment of severe aortic coarctation. We present an adult male patient with aortic coarctation combined with ascending aorta aneurysm and concomitant aortic valve regurgitation. The aortic coarctation was corrected first, using percutaneous balloon dilatation; and in a second stage the aortic regurgitation and ascending aorta aneurysm was treated by Bentall procedure. The patients' postoperative period was uneventful. Three years after the operation he continues to do well.

  6. Two stage hybrid approach for complex aortic coarctation repair

    Science.gov (United States)

    Koletsis, Efstratios; Ekonomidis, Stella; Panagopoulos, Nikolaos; Tsaousis, George; Crockett, James; Panagiotou, Matthew

    2009-01-01

    Background Management of an adult patient with aortic coarctation and an associated cardiac pathology poses a great surgical challenge since there are no standard guidelines for the therapy of such complex pathology. Debate exists not only on which lesion should be corrected first, but also upon the type and timing of the procedure. Surgery can be one- or two-staged. Both of these strategies are accomplice with elevate morbidity and mortality. Case report In the face of such an extended surgical approach, balloon dilatation seems preferable for treatment of severe aortic coarctation. We present an adult male patient with aortic coarctation combined with ascending aorta aneurysm and concomitant aortic valve regurgitation. The aortic coarctation was corrected first, using percutaneous balloon dilatation; and in a second stage the aortic regurgitation and ascending aorta aneurysm was treated by Bentall procedure. The patients' postoperative period was uneventful. Three years after the operation he continues to do well. PMID:19239693

  7. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  8. Balloon Command-Control

    Science.gov (United States)

    1977-01-07

    Continuo on reverse side Ii nocosom7’ and identify by block numnber) P cientific Balloons; Balloon flights; Telemetry; Balloon Control; plight Termination... improvements in the ground station which should result in a truly simplified operation. The final modification to the decoder board which appears... improve the sweep range nnd sweep rate, however, the wave shape is still not as good as achieved using an exter..al sine wave oscillator manually

  9. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  10. Endoluminal treatment of aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, Ajay; Lotz, Joachim; Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Strasse 1, 30625, Hannover (Germany); Oelert, Frank; Haverich, Axel; Karck, Matthias [Department of Thoracic and Cardiovascular Surgery, Hannover Medical School, Carl Neuberg Strasse 1, 30625, Hannover (Germany)

    2003-11-01

    Aortic dissection is most often a catastrophic medical emergency which, if untreated, can be potentially fatal. The intention of therapy in patients with aortic dissection is to prevent aortic rupture or aneurysm formation as well as to relieve branch vessel ischaemia. Patients with aortic dissection are often poor candidates for anaesthesia and surgery and the surgical procedure itself is challenging requiring thoracotomy, aortic cross clamping, blood transfusion as well as prolonged hospital stay in some cases. Operative mortality is especially high in patients with critical mesenteric or renal ischaemia. The past decade has experienced the emergence of a number of interventional radiological or minimally invasive techniques which have significantly improved the management of patients with aortic dissection. These include stent grafting for entry site closure to prevent aneurysmatic widening of the false lumen as well as percutaneous techniques such as balloon fenestration of the intimal flap and aortic true lumen stenting to alleviate branch vessel ischaemia. False lumen thrombosis following entry closure with stent grafts has been observed in 86-100% of patients, whereas percutaneous interventions are able to effectively relieve organ ischaemia in approximately 90% of the cases. In the years to come, it is to be expected that these endoluminal techniques will become the method of choice for treating most type-B dissections and will assist in significantly reducing the number of open surgical procedures required for type-A dissections. The intention of this article is to provide an overview of the current status of these endoluminal techniques based on our own experience as well as on a review of the relevant literature. (orig.)

  11. Endoluminal treatment of aortic dissection

    International Nuclear Information System (INIS)

    Chavan, Ajay; Lotz, Joachim; Galanski, Michael; Oelert, Frank; Haverich, Axel; Karck, Matthias

    2003-01-01

    Aortic dissection is most often a catastrophic medical emergency which, if untreated, can be potentially fatal. The intention of therapy in patients with aortic dissection is to prevent aortic rupture or aneurysm formation as well as to relieve branch vessel ischaemia. Patients with aortic dissection are often poor candidates for anaesthesia and surgery and the surgical procedure itself is challenging requiring thoracotomy, aortic cross clamping, blood transfusion as well as prolonged hospital stay in some cases. Operative mortality is especially high in patients with critical mesenteric or renal ischaemia. The past decade has experienced the emergence of a number of interventional radiological or minimally invasive techniques which have significantly improved the management of patients with aortic dissection. These include stent grafting for entry site closure to prevent aneurysmatic widening of the false lumen as well as percutaneous techniques such as balloon fenestration of the intimal flap and aortic true lumen stenting to alleviate branch vessel ischaemia. False lumen thrombosis following entry closure with stent grafts has been observed in 86-100% of patients, whereas percutaneous interventions are able to effectively relieve organ ischaemia in approximately 90% of the cases. In the years to come, it is to be expected that these endoluminal techniques will become the method of choice for treating most type-B dissections and will assist in significantly reducing the number of open surgical procedures required for type-A dissections. The intention of this article is to provide an overview of the current status of these endoluminal techniques based on our own experience as well as on a review of the relevant literature. (orig.)

  12. The Japanese Balloon Program

    Science.gov (United States)

    Nishimura, J.

    The Japanese scientific ballooning program has been organized by ISAS since the institute was founded in mid 1960s. Since then, the balloon group of ISAS has been engaged in the development of the balloon technologies and scientific observations in collaboration with scientists and engineers in other universities and organizations. Here, I describe several subjects of recent activities, the details of some items will also be reported in the separate papers in this meeting.Preparation of a new mobile receiving station.Balloons of made of the EVAL (Ethylene-Vinyl-Alcohol) films. EVAL film has specific Infra-red absorption bands, and is expected to be useful for saving the ballast for a long duration flight.A high altitude balloon with thin polyethylene films achieving at an altitude of above 50km. Further improvement of this type of balloons is continued by inventing how to extrude thin films less than 5 microns of thickness.Recent achievement of Antarctica Flights under the collaboration of ISAS and National Polar Institute.Other new efforts to long duration flights such as satellite link boomerang balloon systems and others.New balloon borne scientific instrumentation for observations of high energy electrons and Anti-protons in cosmic-rays.

  13. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  14. Modified Hydrogen Balloon Explosion.

    Science.gov (United States)

    Lawrence, Stephen S.

    1995-01-01

    Describes the technique of exploding an oxygen-hydrogen balloon using two balloons and having students observe the formation of water droplets. Suggests that the Socratic Method can be used to start discussions related to stochiometry, states of matter, and gas laws. (DDR)

  15. Aorto-aortic intrathoracic bypass in surgical treatment of aortic

    International Nuclear Information System (INIS)

    Gutierrez Perez, F.; Duran Reyes, A.; Bigalli, D.; Filgueira Berobide, J.

    1998-01-01

    The prevalence of coarctation of the aorta is 6.5 percent of all congenital heart defects, according to national and international data. There is a restenosis rate of patients after surgery. Factors that influence this evolution depends on the age at which patients underwent surgery for the first time the anatomy of the aortic arch and type of surgical technique. Several procedures can be used to correct the coarctation, which include surgery and balloon catheter dilation. We present here a case of a patient of 22 years old, with a recurrent coarctation of the aorta studied by echocardiography and magnetic resonance imaging. The patient underwent surgery a third time. We used an anterior approach (median sternotomy) and performed an aortic bypass graft, intrathoracic, under cardiopulmonary bypass. Evolved favorably and was discharged on the sixth day of post operative day (Author) [es

  16. Wave power absorption by a submerged balloon fixed to the sea bed

    DEFF Research Database (Denmark)

    Kurniawan, Adi; Greaves, Deborah

    2016-01-01

    The possibility of absorbing wave energy using a submerged balloon fixed to the sea bed is investigated. The balloon is in the form of a fabric encased within an array of meridional tendons which terminate at a point at the top of the balloon and at some radius at the bottom. The expansion...... and contraction of the balloon in waves pump air via a turbine into and out of a chamber of constant volume. A more refined model than that used by Kurniawan and Greaves [Proc. 2nd Offshore Energy and Storage Symposium , 2015] predicts a similarly broad-banded response, but the maximum absorption is less than...

  17. Apical ballooning syndrome complicated by acute severe mitral regurgitation with left ventricular outflow obstruction – Case report

    Directory of Open Access Journals (Sweden)

    Celermajer David S

    2007-02-01

    Full Text Available Abstract Background Apical ballooning syndrome (or Takotsubo cardiomyopathy is a syndrome of transient left ventricular apical ballooning. Although first described in Japanese patients, it is now well reported in the Caucasian population. The syndrome mimicks an acute myocardial infarction but is characterised by the absence of obstructive coronary disease. We describe a serious and poorly understood complication of Takotsubo cardiomyopathy. Case Presentation We present the case of a 65 year-old lady referred to us from a rural hospital where she was treated with thrombolytic therapy for a presumed acute anterior myocardial infarction. Four hours after thrombolysis she developed acute pulmonary oedema and a new systolic murmur. It was presumed she had acute mitral regurgitation secondary to a ruptured papillary muscle, ischaemic dysfunction or an acute ventricular septal defect. Echocardiogram revealed severe mitral regurgitation, left ventricular apical ballooning, and systolic anterior motion of the mitral valve with significant left ventricular outflow tract gradient (60–70 mmHg. Coronary angiography revealed no obstructive coronary lesions. She had an intra-aortic balloon pump inserted with no improvement in her parlous haemodynamic state. We elected to replace her mitral valve to correct the outflow tract gradient and mitral regurgitation. Intra-operatively the mitral valve was mildly myxomatous but there were no structural abnormalities. She had a mechanical mitral valve replacement with a 29 mm St Jude valve. Post-operatively, her left ventricular outflow obstruction resolved and ventricular function returned to normal over the subsequent 10 days. She recovered well. Conclusion This case represents a serious and poorly understood association of Takotsubo cardiomyopathy with acute pulmonary oedema, severe mitral regurgitaton and systolic anterior motion of the mitral valve with significant left ventricular outflow tract obstruction. The

  18. Aortic Dissection

    Science.gov (United States)

    ... Follow a low-salt diet with plenty of fruits, vegetables and whole grains and exercise regularly. Wear a seat belt. This reduces the risk of traumatic injury to your chest area. Work with your doctor. If you have a family history of aortic dissection, a connective tissue disorder or ...

  19. Launching Garbage-Bag Balloons.

    Science.gov (United States)

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  20. Venus Altitude Cycling Balloon Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ISTAR Group ( IG) and team mate Thin Red Line Aerospace (TRLA) propose a Venus altitude cycling balloon (Venus ACB), an innovative superpressure balloon...

  1. A Prospective, Randomized Clinical Trial of Hemodynamic Support With Impella 2.5 Versus Intra-Aortic Balloon Pump in Patients Undergoing High-Risk Percutaneous Coronary Intervention The PROTECT II Study

    NARCIS (Netherlands)

    O'Neill, William W.; Kleiman, Neal S.; Moses, Jeffrey; Henriques, Jose P. S.; Dixon, Simon; Massaro, Joseph; Palacios, Igor; Maini, Brijeshwar; Mulukutla, Suresh; Dzavík, Vladimír; Popma, Jeffrey; Douglas, Pamela S.; Ohman, Magnus

    2012-01-01

    Background-Although coronary artery bypass grafting is generally preferred in symptomatic patients with severe, complex multivessel, or left main disease, some patients present with clinical features that make coronary artery bypass grafting clinically unattractive. Percutaneous coronary

  2. Therapeutic balloon-assisted enteroscopy

    NARCIS (Netherlands)

    H. Aktas (Huseyin); P.B.F. Mensink (Peter)

    2009-01-01

    textabstractSince the introduction of the first balloon-based enteroscopic technique in 2001, therapeutic balloon-assisted enteroscopy (BAE) using either the single or double balloon enteroscopy technique (respectively SBE and DBE) has evolved rapidly. Argon plasma coagulation (APC), polypectomy,

  3. Emergency use of cardiopulmonary bypass in complicated transcatheter aortic valve replacement: importance of a heart team approach.

    Science.gov (United States)

    Roselli, Eric E; Idrees, Jay; Mick, Stephanie; Kapadia, Samir; Tuzcu, Murat; Svensson, Lars G; Lytle, Bruce W

    2014-10-01

    Transcatheter aortic valve replacement (TAVR) expands options for high-risk patients with aortic stenosis but is complex with life-threatening complications. We describe indications for use of salvage cardiopulmonary bypass (CPB) and assess outcomes. From 2006 to 2011, 303 patients underwent TAVR, and 12 (4%) required emergency CPB. Approach was transapical (9) and transfemoral (3). Mean age was 82±9 years, median Society of Thoracic Surgeons score was 11 and mean gradient was 46±9 mm Hg. Access for CPB was femoral under fluoroscopy. Principal indication for CPB was hemodynamic instability with or without ischemic changes. These resulted from aortic insufficiency (n=5), valve embolization (n=3), coronary malperfusion (n=2), bleeding requiring pericardiocentesis (n=1), and bleeding from ventricular apex (n=1). Additional procedures included valve-in-valve TAVR (n=5), surgical valve replacement (n=3), and coronary intervention (n=2). Additional circulatory support was used in 7 cases: intra-aortic balloon pump (5) and extracorporeal membrane oxygenation (3). There were 2 hospital deaths. Mean postoperative gradient was 12±9 mm Hg, and median stay was 16 days. There were no myocardial infarctions or renal failure. One patient had stroke with arm weakness, 2 required tracheostomy, and 2 underwent reoperations for bleeding. Median follow-up was 19 months, and there were 5 late deaths. Complications during TAVR can be life threatening and may necessitate additional procedures. Expeditious use of CPB support provided by a multidisciplinary heart team optimizes rescue after myocardial collapse. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  5. Aortic Valve Regurgitation

    Science.gov (United States)

    ... correct direction. These valves include the mitral valve, tricuspid valve, pulmonary valve and aortic valve. Each valve has ... Causes of aortic valve regurgitation include: Congenital heart valve disease. You may have been born with an aortic ...

  6. Aortic embolization of an Edwards SAPIEN prosthesis due to sigmoid left ventricular hypertrophy: Case report.

    Science.gov (United States)

    Yuksel, Isa Öner; Koklu, Erkan; Arslan, Sakir; Cagirci, Goksel; Kucukseymen, Selcuk

    2016-06-01

    Transcatheter aortic valve implantation (TAVI) is considered an alternative therapy in high-risk patients with severe aortic stenosis. Although a minimally invasive procedure, it is not free from complications, one of which is valve embolization at the time of TAVI. We present a case of embolization of a balloon-expandable aortic valve due to sigmoid left ventricular hypertrophy and managed with a second valve without surgery. The embolized valve was repositioned in the aortic arch between the left common carotid artery and the brachiocephalic trunk. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  7. Adjustable continence balloons

    DEFF Research Database (Denmark)

    Kjær, Line; Fode, Mikkel; Nørgaard, Nis

    2012-01-01

    . Fourteen patients (12%) ended up with an artificial sphincter or a urethral sling. Sixty patients (63%) experienced no discomfort and 58 (61%) reported being dry or markedly improved. Overall, 50 patients (53%) reported being very or predominantly satisfied. Conclusions. Adjustable continence balloons seem...

  8. Impact of a single universal guiding catheter on door-to-balloon time in primary transradial coronary intervention for ST segment elevation myocardial infarction.

    Science.gov (United States)

    Torii, Sho; Fujii, Toshiharu; Murakami, Tsutomu; Nakazawa, Gaku; Ijichi, Takeshi; Nakano, Masataka; Ohno, Yohei; Shinozaki, Norihiko; Yoshimachi, Fuminobu; Ikari, Yuji

    2017-04-01

    The purpose of this study is to determine reduction of door-to-balloon (D2B) time using a single universal guiding catheter (Ikari-Left catheter) in transradial approach. In this procedure, we can skip a total of five steps compared with a conventional procedure (two catheter insertions, two catheter removals, and one catheter engagement). Reducing total ischemic time is important to achieving a better outcome in primary percutaneous coronary intervention (PCI) for ST segment elevation myocardial infarction (STEMI). We retrospectively compared 30 consecutive STEMI patients who underwent transradial primary PCI with a single guiding catheter (IL group) with 30 consecutive patients with conventional transradial primary PCI. Patients with cardiogenic shock, heart failure, or need for intra-aortic balloon pumping support before primary PCI were excluded. Baseline characteristics were not different between the two groups. The D2B time was significantly shorter in the IL group (55 ± 16 vs. 63 ± 17 min, respectively; p = 0.01). Puncture-to-balloon time was also significantly shorter in the IL group (15 ± 11 min vs. 25 ± 11 min, respectively; p = 0.001). The total number of diagnostic and guiding catheters was significantly less in IL group (1 (IQR 1-1) vs. 3 (IQR 3-3), respectively; p guiding catheter reduced D2B time by skipping several procedural steps, and reduced the total number of catheters needed. This technique could reduce patient mortality as well as total medical cost.

  9. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  10. Bicuspid Aortic Valve

    Science.gov (United States)

    2006-08-01

    with tricuspid aortic valves matched for age, gender and grade of valvular disease . These studies suggest that the predisposition for aortic...enlargement in healthy patients with normally functioning BAV when compared to healthy subjects with normally functioning tricuspid aortic valves ...ascending aorta but also in the pulmonary arteries of patients with BAV, compared to that of patients with tricuspid aortic valves . These studies

  11. Surgical versus percutaneous treatment of aortic coarctation: new standards in an era of transcatheter repair.

    Science.gov (United States)

    Luijendijk, Paul; Bouma, Berto J; Groenink, Maarten; Boekholdt, Matthijs; Hazekamp, Mark G; Blom, Nico A; Koolbergen, Dave R; de Winter, Robbert J; Mulder, Barbara J M

    2012-12-01

    Aortic coarctation is a common congenital cardiovascular defect, which can be diagnosed over a wide range of ages and with varying degrees of severity. Surgery has proven to be an effective treatment for the management of native aortic coarctation, and remains the treatment of choice in neonates. Balloon angioplasty with or without stenting has evolved rapidly over the past decade. Balloon angioplasty is the treatment of choice in children with re-coarctation, and currently available immediate results in native coarctation are similar with regards to gradient reduction as compared with surgery. However, both treatment options carry the risk of restenosis and aortic wall complications, especially after balloon angioplasty without stenting in native coarctation. On the other hand, stent implantation has shown excellent short-term results in both children beyond infancy and in adults with native coarctation. In patients with recurrent coarctation who are at high surgical risk, balloon angioplasty and stent repair offer a less invasive and equally effective method. Stent repair is preferred over balloon angioplasty in adults and outgrown children with a recurrent coarctation, as the risk for re-coarctation and aneurysm formation seems to be lower. Data with regard to long-term outcome after percutaneous treatment strategies are scarce. This review summarizes the current insights in the efficacy and safety of both surgical and transcatheter treatment options for aortic coarctation.

  12. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  13. Complications of intra-aortic balloon in a cohort of hospitalized patients: implications for nursing care Complicaciones del balón intraaórtico en una cohorte de pacientes hospitalizados: implicaciones para la asistencia de enfermería Complicações do balão intra-aórtico em uma coorte de pacientes hospitalizados: implicações para a assistência de enfermagem

    Directory of Open Access Journals (Sweden)

    Renata Bacelar Silva de Assis

    2009-10-01

    Full Text Available OBJECTIVES: To describe complications associated to the use of intra-aortic balloon pumps (IABP, and their relationship with dwelling time, presence of risk factors/comorbidities, and nursing records. METHODS: Retrospective cohort study, in which medical records were analyzed through the completion of specifically designed forms. RESULTS: In total, 104 patients were included, with mean age 65±11 years, 52% men; 26 (25% of them presented vascular complications, more frequently ischemia (25%; peripheral vascular disease was the risk factor/comorbidity more frequently related to complications (56.3%; p=0.003. Nursing records showed that the use of catheter was recorded in 30 cases (29%, and the patient's clinical situation after its removal in 28 cases (27%. CONCLUSION: This study showed that the frequency of complications related to IABP is high. Considering risk factor/comorbidity factors, peripheral vascular disease was significantly associated to complications. Nursing records were sub-optimal.Este estudio tuvo como objetivos describir las complicaciones provenientes de la utilización del balón intraaórtico (BIA, relacionándolas con el tiempo de permanencia, con la presencia de factores de riesgo/enfermedades concomitantes y con los registros de enfermería. Se utilizó como método la cohorte histórica, con análisis de fichas por medio del llenado de un instrumento construido específicamente para el estudio. Después de la evaluación de 104 pacientes, edad promedio 65±11, 52% sexo masculino, los resultados mostraron que 26 (25% presentaron complicaciones vasculares, siendo la isquemia (25% la más incidente; entre los factores de riesgo/enfermedades concomitantes, el que más se relacionó con complicaciones fue la enfermedad vascular periférica (56,3%, p=0,003. En lo que se refiere a las evaluaciones de enfermería, 30 (29% presentaban registro del uso del catéter, y 28 (27% relataban el estado clínico del paciente después de su

  14. Insulin Pumps

    Science.gov (United States)

    ... Size: A A A Listen En Español Insulin Pumps Insulin pumps are small computerized devices that deliver insulin in ... tissue and is taped in place. The insulin pump is not an artificial pancreas (because you still ...

  15. Penis Pump

    Science.gov (United States)

    ... your appointment might be less involved. Choosing a penis pump Some penis pumps are available without a ... it doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines ...

  16. Quadricuspid Aortic Valve Combined with Moderate Ascending Aortic Dilatation

    Science.gov (United States)

    Uspenskiy, Vladimir E.; Osadchii, Alexei M.; Gordeev, Mikhail L.

    2015-01-01

    The quadricuspid aortic valve is a very uncommon malformation associated with aortic insufficiency, aortic stenosis, endocarditis, and ascending aortic dilatation. We report four cases of this aortic valve malformation. One patient with severe aortic regurgitation and moderate aortic dilatation required aortic valve replacement. Three patients had mild or moderate aortic insufficiency combined with moderate ascending aortic dilatation. These patients were referred to follow-up. The presented cases demonstrate that this aortic valve malformation may not be as rare as it appears and that attention must be paid to any quadricuspid findings during computed tomographic angiography and echocardiography. PMID:27390747

  17. Fracture of the delivery balloon shaft during balloon-expandable prosthesis alignment during implantation of an Edwards SAPIEN 3.

    Science.gov (United States)

    Arai, Takahide; Hovasse, Thomas; Chevalier, Bernard

    2018-04-01

    The expandable sheath was designed with a lower profile in order to reduce the incidence of vascular complications of transcatheter aortic valve implantation using transfemoral approach. However, once the prosthesis has crossed the sheath, it could be difficult to retrieve it from the body. This is the first case of successful bail-out in an instance of delivery balloon shaft malfunction subsequent to the crossing of an expandable sheath during implantation of an Edwards SAPIEN 3 prosthesis. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. VVER ballooning experiments

    International Nuclear Information System (INIS)

    Gyoeri, Cs.; Hozer, Z.; Maroti, L.; Matus, L.

    1998-01-01

    A series of ballooning experiments was performed at the KFKI-AEKI in order to compare the mechanical behaviour and strength of Zircaloy-4 and Zr1%Nb claddings. The effects of temperature, oxidation and iodine absorption on deformation and burst pressure was investigated in almost 100 biaxial tests. Numerical post-test analyses have also been performed with the stand-alone fuel module of the French CATHARE code and the US fuel behaviour code FRAP-T6. Comparing the experimental and the analytical results, relevant differences of high temperature strength due to different α-β phase transition temperature were revealed between the investigated cladding materials. (author)

  19. Aerodynamics of a Party Balloon

    Science.gov (United States)

    Cross, Rod

    2007-01-01

    It is well-known that a party balloon can be made to fly erratically across a room, but it can also be used for quantitative measurements of other aspects of aerodynamics. Since a balloon is light and has a large surface area, even relatively weak aerodynamic forces can be readily demonstrated or measured in the classroom. Accurate measurements…

  20. O uso do balão intra-aórtico no pré-operatório de cirurgia de revascularização miocárdica, associada à disfunção ventricular grave The use of preoperative intra-aortic balloon in myocardial revascularization surgery associated to severe ventricular dysfunction

    Directory of Open Access Journals (Sweden)

    Marcelo Kern

    2006-02-01

    Full Text Available OBJETIVO: Avaliar a efetividade do Balão Intra-Aórtico (BIAo profilático em cirurgia de revascularização miocárdica (CRM eletiva, para prevenir o infarto trans ou pós-operatório e para reduzir a mortalidade intra-hospitalar nos pacientes com baixa fração de ejeção ventricular esquerda. MÉTODOS: Em modelo de estudo de coorte, foram analisados 239 pacientes com fração de ejeção do ventrículo esquerdo inferior ou igual a 40%, submetidos à CRM eletiva com circulação extracorpórea (CEC, no período compreendido entre março de 1995 a fevereiro de 2001. RESULTADOS: Destes, 58 pacientes receberam BIAo pré-operatório e os demais foram operados sem assistência circulatória (grupo controle. Os dois grupos de pacientes tinham características semelhantes quanto a fatores associados aos desfechos em questão. Ocorreram 5 (8,6% óbitos no grupo com BIAo e 21 (11,6%, no grupo controle (diferença não-signifícativa. Ocorreram 2 (3,4% infartos no grupo com BIAo e 28 (15,5%, no grupo controle BIAo (p OBJECTIVE: To evaluate the effectiveness of prophylactic intra-aortic balloon (IAB in elective myocardial revascularization surgery (MRS, to prevent trans or post-operative infarction and reduce intra-hospital mortality in patients with low left ventricular ejection fraction. METHODS: Using a cohort study model, 239 patients with left ventricular ejection fraction <40%, submitted to elective MRS with extracorporeal circulation (ECC were evaluated from March 1995 to February 2001. RESULTS: Of these, 58 patients received preoperative IAB and the remainder underwent surgery without circulatory assistance (control group. The two groups of patients had similar characteristics regarding factors associated to the pertaining outcomes. There were five demises (8.6% in the group with IAB and 21 (11.6% in the control group (non-significant difference. There were 2 (3.4% infarctions in the IAB group and 28 (15.5% in the control group (p< 0

  1. Off-Pump Repair of a Post Myocardial Infarction Ventricular Septal Defect

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2014-01-01

    Full Text Available Refractory cardiogenic shock meant that traditional patch repairs requiring cardiopulmonary bypass would be poorly tolerated and external sandwich closure of post myocardial ventricular septal defect (VSD appears to be simple and effective after initial myocardial infarction (MI. The three cases presented with a VSD after of acute MI with or without thrombolysed with streptokinase during patient admission. The general condition of the three patients was poor with pulmonary edema, low cardiac output and renal failure. The heart was approached through a median sternotomy. Off-pump coronary artery bypass grafting of the coronary artery lesion was done first using octopus and beating heart surgery method and latero - lateral septal plication was performed using sandwich technique. Low cardiac output managed with intra-aortic balloon pump in these patients accompanied with inotropic drugs. Post-operative transesophageal echocardiography revealed that VSD was closed completely in one patient and in two patients small residual VSD remained. More experience is required to ascertain whether this technique will become an accepted alternative to patch repairs.

  2. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  3. Aortic Annular Enlargement during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Selman Dumani

    2016-09-01

    Full Text Available In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.

  4. [Hemodynamic analysis of a centrifugal blood pump].

    Science.gov (United States)

    Wang, Yang; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Li, Qilei; Xu, Liang

    2015-01-01

    This paper built the mathematical model of a centrifugal blood pump, which was designed by ourselves, combined it with that of the human cardiovascular system and simulated the coupling system using Matlab. Then we set up the experiment platform, linked the blood pump to mock human cardiovascular system in case of three-stage heart failure, and measured aortic pressure and flow under different speed. The comparison between experiment results and simulation results not only indicates the coupling model is correct and the blood pump works well, but also shows that with the increase of blood pump speed, the pulsation of aortic pressure and flow will be reduced, this situation will affect the structure and function of blood vessels.

  5. Transcatheter therapy for aortic coarctation with severe systemic hypertension during pregnancy.

    Science.gov (United States)

    Assaidi, Anass; Sbragia, Pascal; Fraisse, Alain

    2013-10-01

    Aortic coarctation is an unusual cause of hypertension during pregnancy and its management is not clarified. We report transcatheter balloon dilatation and stenting for native aortic coarctation in a 22-year-old pregnant woman with severe and uncontrolled systemic hypertension. Arterial blood pressure could be successfully controlled with medical treatment during the rest of the pregnancy and the patient underwent uneventful delivery. No adverse events or recoarctation was observed during 24 months clinical follow-up. In conclusion, native aortic coarctation can be successfully treated during pregnancy with transcatheter therapy. More experience is needed to confirm the safety and efficacy of such management. Copyright © 2012 Wiley Periodicals, Inc.

  6. Air Force Cambridge Research Laboratories balloon operations

    Science.gov (United States)

    Danaher, T. J.

    1974-01-01

    The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.

  7. 21 CFR 874.4100 - Epistaxis balloon.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Epistaxis balloon. 874.4100 Section 874.4100 Food... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4100 Epistaxis balloon. (a) Identification. An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal...

  8. Different transcatheter strategies for aortic coarctation associated with patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2012-07-01

    Conclusions: In coarctation with patent ductus arteriosus associated with good sized aortic isthmus, closure of duct with duct occluder device and balloon aortoplasty would correct the lesions. If there is isthmic hypoplasia, device closure of the duct and stenting of the coarctation is needed. Covered stent is a reasonable alternative only in presence of non dilated descending aorta.

  9. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  10. Under Pressure: Activities with a Vacuum Pump (and Some Marshmallows) Help Students Learn about Pressure.

    Science.gov (United States)

    Galus, Pamela

    2002-01-01

    Introduces a science demonstration that illustrates the effects of pressure and gravity on humans using a marshmallow man and a vacuum pump. Demonstrates the same concept with shaving cream, balloons, and boiling water without raising temperature. (YDS)

  11. Endovascular treatment of acute type B dissection complicating aortic coarctation.

    Science.gov (United States)

    Kassaian, Seyed Ebrahim; Abbasi, Kyomars; Mousavi, Mehdi; Sahebjam, Mohammad

    2013-01-01

    Surgical treatment poses a high risk to patients with concomitant aortic coarctation and dissection, and an interventional approach could be an alternative. We describe the case of a 52-year-old man with a long history of untreated hypertension and aortic coarctation who emergently presented at our institution with an acute Stanford type B dissection. The patient's elevated serum creatinine level, perfusion deficit in the right lower limb, and hypertension did not respond to medical therapy, and he did not consent to surgery. By endovascular means, we used a self-expandable stent-graft to cover the entry point of the dissection; then, we deployed a balloon-expandable bare-metal stent to correct residual stenosis. To our knowledge, this is the first report of the endovascular treatment of aortic coarctation complicated by type B dissection.

  12. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  13. US Daily Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Pilot Balloon observational forms for the United States. Taken by Weather Bureau and U.S. Army observers. Period of record 1918-1960. Records scanned from the NCDC...

  14. Retrieving Balloon Data in Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Ultra Long Duration Balloon (ULDB) program will soon make flights lasting up to 100 days. Some flights may generate high data rates and retrieving this data...

  15. US Monthly Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Monthly winds aloft summary forms summarizing Pilot Balloon observational data for the United States. Generally labeled as Form 1114, and then transitioning to Form...

  16. Superpressure Tow Balloon for Extending Durations and Modifying Trajectories of High Altitude Balloon Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation involves the concept of using a Superpressure Tow Balloon (STB) with existing NASA high altitude balloon designs to form a tandem balloon...

  17. A new approach to the diagnosis of esophageal rupture due to balloon dilatation

    International Nuclear Information System (INIS)

    Song, Ho Young; Han, Young Min; Lee, Sang Young; Kuh, Ja Hong; Lee, Dong Kun; Chae, Soo Wan

    1990-01-01

    The diagnosis of esophageal rupture in balloon dilatation is usually made from clinical symptom of sharp chest pain, plain chest radiographs and esophagograms after dilation. It has some problems; the pain is varied patients to patients and bacterial flora in the mouth or esophagus can be mixed with the contrast media to flow into the mediastinum during esophagography, to create mediastinitis. We could make the diagnosis of esophageal rupture without using contrast media by the observation of the pressure change in the balloon during dilatation. An infusion pump, transducer and esophageal balloon were connected through a multi-way connector, and the transducer of them was also connected to an amplifier which was connected to a pressure monitor to record the balloon pressure. As balloon(20mm/3cm) inserted in the mid-thoracic esophagus under the fluoroscopic control was inflated until the esophagus was ruptured. Balloon was distended by injecting air in 15 rabbits(A group), and by injecting diluted contrast medium in 15 rabbits(B group). The pressure decrease after esophageal rupture was ranged from 94 to 160 mmHg(mean; 103) in A group and 340 to 1040 mmHg(mean; 537) in B group. The pressure curve of A group was smooth, regular and so accurate to make the diagnosis of esophageal rupture, whereas that of B group was irregular and not so accurate. In conclusion, our new method to make the diagnosis of esophageal rupture during balloon dilatation may be useful in patients of esophageal stricture

  18. Pioneering Space Research with Balloons

    Science.gov (United States)

    Jones, W. V.

    NASA s Scientific Ballooning Planning Team has concluded that ballooning enables significant scientific discoveries while providing test beds for space instruments and training for young scientists Circumpolar flights around Antarctica have been spectacularly successful with fight durations up to 42 days Demand for participation in this Long-Duration Balloon LDB program a partnership with the U S National Science Foundation Office of Polar Programs is greater than the current capacity of two flights per campaign Given appropriate international agreements LDB flights in the Northern Hemisphere would be competitive with Antarctic flights and super-pressure balloons would allow comparable flights at any latitude The Balloon Planning Team made several recommendations for LDB flights provide a reliable funding source for sophisticated payloads extend the Antarctic capability to three flights per year and develop a comparable capability in the Arctic provide aircraft for intact-payload recovery develop a modest trajectory modification capability to enable longer flights and enhance super-pressure balloons to carry 1-ton payloads to 38 km Implementation of these recommendations would facilitate frequent access to near-space for cutting-edge research and technology development for a wide range of investigations

  19. Percutaneous balloon valvuloplasty in mitral stenosis

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Oh, Byung Hee; Park, Kyung Ju; Kim, Seung Hyup; Lee, Young Woo; Han, Man Chung

    1989-01-01

    Percutaneous balloon valvuloplasty(PBV) was successfully performed in 8 mitral stenosis patients for recent 3 months. Five patients have aortic insufficiencies also and two patients have mitral regurgitations below grade II/IV. All patients showed sinus rhythm on EKG, and had no mitral valvular calcification on echocardiography and fluoroscopy. PBV resulted in an increase in mitral valve area from 1.22±0.22 to 2.57±0.86 cm 2 , a decrease in mean left atrial pressure from 23.4±9.6 to 7.5±3.4 mmHg and a decrease in mean mitral pressure gradient from 21.3±9.4 to 6.8±3.1 mmHg. There were no significant complications except 2 cases of newly appeared and mildly aggravated mitral regurgitation. We believe that PBV will become a treatment modality of choice replacing surgical commissurotomy or valve replacement in a group of mitral stenosis patients, because of its effectiveness and safety

  20. [Application of temporary balloon blocking technique in bone tumors surgery under the aid of CT angiography].

    Science.gov (United States)

    Fang, Cheng; Hu, Yongcheng; Huang, Hongchao; Xia, Qun; Chen, Xiaopeng; Yuan, Binbin; He, Xin; Wang, Peng

    2014-10-01

    To study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. A retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. The CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545 ± 0.248) cm and (1.060 ± 0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818 ± 1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months

  1. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  2. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  3. Impact of around-the-clock in-house cardiology fellow coverage on door-to-balloon time in an academic medical center

    Science.gov (United States)

    Kohan, Luke C; Nagarajan, Vijaiganesh; Millard, Michael A; Loguidice, Michael J; Fauber, Nancy M; Keeley, Ellen C

    2017-01-01

    Objectives To assess if a change in our cardiology fellowship program impacted our ST elevation myocardial infarction (STEMI) program. Background Fellows covering the cardiac care unit were spending excessive hours in the hospital while on call, resulting in increased duty hours violations. A night float fellow system was started on July 1, 2012, allowing the cardiac care unit fellow to sign out to a night float fellow at 5:30 pm. The night float fellow remained in-house until the morning. Methods We performed a retrospective study assessing symptom onset to arrival, arterial access to first device, and door-to-balloon (D2B) times, in consecutive STEMI patients presenting to our emergency department before and after initiation of the night float fellow system. Results From 2009 to 2013, 208 STEMI patients presented to our emergency department and underwent primary percutaneous coronary intervention. There was no difference in symptom onset to arrival (150±102 minutes vs 154±122 minutes, p=0.758), arterial access to first device (12±8 minutes vs 11±7 minutes, p=0.230), or D2B times (50±32 minutes vs 52±34 minutes, p=0.681) during regular working hours. However, there was a significant decrease in D2B times seen during off-hours (72±33 minutes vs 49±15 minutes, p=0.007). There was no difference in in-hospital mortality (11% vs 8%, p=0.484) or need for intra-aortic balloon pump placement (7% vs 8%, p=0.793). Conclusion In academic medical centers, in-house cardiology fellow coverage during off-hours may expedite care of STEMI patients. PMID:28458558

  4. Sensor System for Super-Pressure Balloon Performance Modeling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-duration balloon flights are an exciting new area of scientific ballooning, enabled by the development of large super-pressure balloons. As these balloons...

  5. Acute aortic syndromes: current status.

    Science.gov (United States)

    Ridge, Carole A; Litmanovich, Diana E

    2015-05-01

    The term acute aortic syndrome comprises aortic dissection, intramural hematoma, and penetrating atherosclerotic ulcer. The most recent developments in acute aortic syndromes include (1) a change in the mindset that each entity is pathologically distinct, with a shift toward considering the acute aortic syndromes as points along a spectrum of aortic disease, (2) the optimization of aortic imaging quality and radiation dose, and (3) surgical or endovascular management. This review article focuses on how these developments pertain to thoracic radiologists.

  6. Primary metastasizing aortic endothelioma.

    Science.gov (United States)

    Schmid, E; Port, S J; Carroll, R M; Friedman, N B

    1984-10-01

    An instance of malignant endothelioma, primary in the aorta, metastasizing to intestine and bone, is reported. The aortic tumor was successfully resected. The unexpected finding of a large hepatic growth at autopsy raised the possibility that the aortic neoplasm was a metastasis. Histochemical, immunologic, and ultrastructural studies supported the diagnosis of an endothelial neoplasm. Although a number of malignant aortic and large vessel tumors have been reported, only four previous instances appear to be endotheliomatous.

  7. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    BACKGROUND AND AIMS OF THE STUDY: Prompted by anecdotal evidence and observations by surgeons, an investigation was undertaken into the potential differences in implanted aortic valve prosthesis sizes, during aortic valve replacement (AVR) procedures, between northern and southern European...... assigned to the 'small' aortic size subset. Effective orifice area indices were calculated for all patients to assess the geographic distribution of patient-prosthesis mismatch. Univariable and multivariable logistic regression analyses adjusting for possible confounding variables were performed. RESULTS...

  8. Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

    Science.gov (United States)

    Kogut, Alan; James, Bryan; Fixsen, Dale

    2013-01-01

    Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then

  9. Status of the NASA Balloon Program

    Science.gov (United States)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-01-01

    The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.

  10. Acoustic Detection from Aerial Balloon Platform

    National Research Council Canada - National Science Library

    Reiff, C; Pham, T; Scanlon, M; Noble, J; Van Landuyt, A; Petek, J; Ratches, J

    2004-01-01

    ... such as unmanned aerial vehicles (UAVs) and balloons. Our most immediate collaboration focuses on the use of acoustic sensors on small balloons and/or aerostats at several elevations and on the ground with the primary goals...

  11. Mars Solar Balloon Lander, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  12. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  13. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  14. Comparative in vivo analysis of the role of the adventitia and the endothelium on arterial mechanical function: relevance for aortic counterpulsation.

    Science.gov (United States)

    Bia, Daniel; Zócalo, Yanina; Wray, Sandra; Cabrera-Fischer, Edmundo I

    2017-06-09

    The comparative effect of the intimal and adventitial layers on arterial biomechanics control, in basal and altered conditions, remains to be elucidated. This study aimed (1) to characterize the arterial conduit (CF) and buffering (distensibility) function of the iliac arteries in in vivo animals, in which the intimal and adventitial layers were removed; (2) to determine the effects of intra-aortic ballon pumping (IABP) on simultaneously de-adventitialized (DA) and de-endothelialized (DE) iliac arteries before and after induced heart failure. Pressure and diameter signals were measured in the iliac arteries of sheep (n = 7) in which the adventitial and intima layer were removed. Intra-aortic balloon pump (IABP) assistance was used in a control state and after heart failure induction. Both DE and DA determined significant changes in arterial diameter, distensibility and CF. Changes were higher after DA than after DE in terms of distensibility and CF (p<0.05). DA followed by DE (DA + DE) showed significant increases in arterial diameter and CF, accompanied by a decrease in distensibility (p<0.05) with respect to intact arteries. Heart failure induction caused significant hemodynamic changes without modifying the already impaired local biomechanical parameters. Nonsignificant improvements in the biomechanical parameters of DA + DE iliac arteries were observed during IABP before and after heart failure induction. Biomechanical changes caused by DA of iliac arteries were more important than those observed after DE. The DA + DE arteries showed significant differences with respect to intact arteries and with DA or DE arteries. IABP-related effects on arterial mechanics were absent in DA + DE arteries.

  15. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family...... of membrane proteins: P-type ATPase pumps. This article takes the reader on a tour from Aarhus to Copenhagen, from bacteria to plants and humans, and from ions over protein structures to diseases caused by malfunctioning pump proteins. The magazine Nature once titled work published from PUMPKIN ‘Pumping ions...

  16. Application of new balloon catheters in the treatment of congenital heart defects

    Directory of Open Access Journals (Sweden)

    Roland Fiszer

    2016-08-01

    Full Text Available Introduction : Balloon angioplasty (BAP and aortic or pulmonary balloon valvuloplasty (BAV, BPV are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim: To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland launched and developed. These catheters have not been clinically evaluated yet. Material and methods: We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF, 10 BAV and 27 BAP in coarctations of the aorta (CoA – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations, 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results: All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean, BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin. No such complication occured with Valver II. Conclusions : Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses.

  17. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  18. The development of coastal diffusion observation method with a captive balloon

    International Nuclear Information System (INIS)

    Fukuda, Masaaki; Yamada, Masaharu

    1980-03-01

    Apparatus whereby the dye cloud in a coastal area in diffusion experiment can be photographed was developed. It consists of a vinyl balloon two meters in diameter, a photographic device with the camera shutter released by wireless signals from the ground, and a winch to raise or lower the balloon. A maximum height of the balloon for taking photographs is 1000 m. During the single balloon flight, thirty photographs can be taken. With the balloon at a certain height, dye as the tracer in diffusion experiment is released at sea surface or a certain sea depth by dye-throwing means or pump, and then taking the photographs is started. Movement and diffusion of the dye are analyzed by means of the photographs taken. The apparatus is simple in mechanism and easy to transport. Dye experiment is possible in the surfe zone where a boat cannot enter. It is impossible, however, to raise the balloon in strong wind or sea breeze. Typical results of the dye diffusion experiment with the apparatus are given. (author)

  19. Aortic valve surgery - open

    Science.gov (United States)

    ... while you are connected to this machine. This machine does the work of your heart while your heart is stopped. If your aortic valve is too damaged, you will need a new valve. This is called replacement surgery. Your surgeon will remove your aortic valve ...

  20. Imaging in aortic dissection

    International Nuclear Information System (INIS)

    Yu-Qing Liu, M.D.

    1995-01-01

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.)

  1. Aortic arch malformations

    International Nuclear Information System (INIS)

    Kellenberger, Christian J.

    2010-01-01

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  2. [Traumatic aortic valve insufficiency].

    Science.gov (United States)

    Nascimento, J; Lemos, C; Marques, A M; Antunes, M J; Gonsalves, A

    1996-02-01

    The traumatic aortic valvular insufficiency (TAVI), through less frequent after a non-penetrating thoracic traumatism, is a serious entity with a very reserved prognosis. So it must be suspected in every patients with signs or symptoms of de novo heart failure post-traumatism. The transthoracic echocardiography and eventually transesophageal echocardiography have a fundamental role in the confirmation of the diagnosis. The clinical picture of traumatic aortic regurgitation is quickly evolutionary and the non efficacy of medical therapy has placed the valvular substitution surgery as the best succeeded treatment. With the advent of the aortic valve repairing surgery some TAVI cases has been submitted to this procedure. Nevertheless, the development of residual aortic regurgitation in these situations, usually requiring later valvular replacement surgery, make the aortic valvuloplasty a controversial surgical technique. The AA describe a recent clinical case of aortic regurgitation after a non-penetrant thoracic traumatism, discussing the aspects connected with physiopathology, diagnosis and therapy. The singularity of this case was based on the fact that the initial clinical diagnosis had been prejudiced by the context of a polytraumatism and there had been a time free of symptoms between the traumatism and the beginning of the symptomatology of left ventricular failure. Even though the identification of the problem allowed an intensive treatment of this serious situation that ended with the replacement of the aortic valve by mechanical aortic prosthesis, with the patient's total recovery.

  3. Rapid Two-stage Versus One-stage Surgical Repair of Interrupted Aortic Arch with Ventricular Septal Defect in Neonates

    Directory of Open Access Journals (Sweden)

    Meng-Lin Lee

    2008-11-01

    Conclusion: The outcome of rapid two-stage repair is comparable to that of one-stage repair. Rapid two-stage repair has the advantages of significantly shorter cardiopulmonary bypass duration and AXC time, and avoids deep hypothermic circulatory arrest. LVOTO remains an unresolved issue, and postoperative aortic arch restenosis can be dilated effectively by percutaneous balloon angioplasty.

  4. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  5. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  6. Scientific ballooning: Past, present and future

    Science.gov (United States)

    Jones, W. Vernon

    2013-02-01

    Balloons have been used for scientific research since they were invented in France more than 200 years ago. Cosmic rays were discovered 100 years ago with an experiment flown on a manned balloon. A major change in balloon design occurred in 1950 with the introduction of the socalled natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for the past half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing a super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. Ultra-long-duration balloon (ULDB) flights enabled by constant-volume balloons should result in an even greater sea change in scientific ballooning than the inauguration of long-duration balloon (LDB) flights in Antarctica during the 1990-91 austral summer.

  7. Circumferential ascending aortic strain and aortic stenosis.

    Science.gov (United States)

    Teixeira, Rogério; Moreira, Nádia; Baptista, Rui; Barbosa, António; Martins, Rui; Castro, Graça; Providência, Luís

    2013-07-01

    Two-dimensional speckle tracking (2D-ST) echocardiography for the measurement of circumferential ascending thoracic aortic strain (CAAS) in the context of aortic stenosis (AS) is not elucidated. Purpose This study assesses the thoracic ascending aortic deformation using 2D-ST echocardiography in AS patients. Population and methods Forty-five consecutive patients with an aortic valvular area (AVA) ≤0.85 cm(2)/m(2) were included. Regarding aortic deformation, the global peak CAAS was the parameter used, and an average of six segments of arterial wall deformation was calculated. The corrected CAAS was calculated as the global CAAS/pulse pressure (PP). Aortic stiffness (β2) index was assessed according to ln(Ps/Pd)/CAAS. The sample was stratified according to the stroke volume index (SVI) as: Group A (low flow, SVI ≤35 mL/m(2); n = 19) and Group B (normal flow, SVI >35 mL/m(2); n = 26). The mean age was 76.8 ± 10.3 years, 53.3% were male, the mean indexed AVA was 0.43 ± 0.15 cm(2)/m(2), and the mean CAAS was 6.3 ± 3.0%. The CAAS was predicted by SVI (β = 0.31, P < 0.01) and by valvulo-arterial impedance (Zva). The corrected CAAS was correlated with the M-mode guided aortic stiffness index (β1) (r = -0.39, P < 0.01), and was predicted by SVI, Zva, and systemic arterial compliance (β = 0.15, P < 0.01). The β2 index was significantly higher for the low-flow patients (16.1 ± 4.8 vs. 9.8 ± 5.3, P < 0.01), and was predicted by SVI (β -0.58, P < 0.01) and PP (β = 0.17, P < 0.01). Global CAAS was more accurate to predict low flow than Zva, systolic function and systemic vascular resistance. In patients with moderate-to-severe aortic stenosis, SVI and LV afterload-related variables were the most important determinants of 2S-ST global CAAS.

  8. Heart failure - surgeries and devices

    Science.gov (United States)

    CHF - surgery; Congestive heart failure - surgery; Cardiomyopathy - surgery; HF - surgery; Intra-aortic balloon pumps - heart failure; IABP - heart failure; Catheter based assist devices - heart failure

  9. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  10. Development of scientific ballooning in Japan

    Science.gov (United States)

    Nishimura, Jun

    On the occasion of the 50th Anniversary Celebration of COSPAR of this year of 2008, it is worthwhile to summarize the results of the Scientific ballooning in early days in connection with the recent developments in various countries. Nishina Laboratories, Riken, had started the observations of cosmic rays with rubber balloons as early as 1942. However it was interrupted soon by the war II. After the war, new research group started in collaboration with several universities with nuclear emulsions put on the rubber balloons in 1950, and then soon after the group manufactured by themselves and launched the first plastic balloon in 1953. Based on additional technologies during a few years developed by these group, the Institute of Nuclear Study, INS, the University of Tokyo, organized the large campaign of 14 emulsion chambers and a pellicle stack with 8 plastic balloons in 1956. It is to be noted that the project was one of the largest in the world standard in those days. By the experience of this campaign, the importance of the balloon technologies was more recognized, and INS organized the group to study the balloon technologies, and had established some developments. The systematic study of scientific ballooning has started, when the scientific ballooning laboratory was founded in 1965, in the new Institute of ISAS, the University of Tokyo. The permanent balloon base of "Sanriku Balloon Center" was founded in 1971. This group has expended all efforts for the scientific ballooning, launching 10-20 balloons in each year with new inventions such as the studies of; Technologies to manufacture the reliable plastic balloons, New Balloon materials, New instrumentations for scientific ballooning, Systems of long duration flights including Antarctica flights, International collaboratiom, etc. Up to now almost 600 plastic balloons were launched during past 50 years. Then the scientific balloonings have played important and indispensable roles for the development of space

  11. Electrokinetic pump

    Science.gov (United States)

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  12. Sutureless Aortic Prosthesis Implantation: the First Brazilian Experience with Perceval Device.

    Science.gov (United States)

    Tagliari, Ana Paula; de Moura, Leandro; Dussin, Luiz Henrique; Saadi, Eduardo Keller

    2016-01-01

    This is a report of the first Brazilian experience with the Perceval sutureless aortic prosthesis in two patients with severe aortic stenosis. Transesophageal echocardiography was used during the procedure. The aortotomy was performed 1 cm above the sinotubular junction, followed by leaflets removal and decalcification. Correct valve size was selected, device released and an accommodation balloon used. The cardiopulmonary bypass times were 47 and 38 min and the cross-clamp times were 38 and 30 min. There was a significant decrease in mean gradients (41 and 75 mmHg preoperatively; 7 and 8 mmHg postoperatively). There was no major complication or paravalvular leak.

  13. Three-year-old child with middle aortic syndrome treated by endovascular stent implantation.

    Science.gov (United States)

    Moszura, Tomasz; Goreczny, Sebastian; Dryzek, Pawel; Niwald, Marek

    2013-04-01

    Middle aortic syndrome (MAS) is an extremely rare anomaly and represents both a diagnostic and therapeutic challenge, particularly in young children. A case of a 3.5 year-old child with MAS and arterial hypertension is reported, where owing to the patient's young age and the length of the hypoplastic aortic segment, surgical correction with end-to-end anastomosis was not feasible. Instead of palliative bypass grafting between the thoracic and abdominal aorta, successful percutaneous balloon angioplasty and stenting of the lesion was performed with the assistance of three-dimensional rotational angiography.

  14. Severe Aortic Stenosis and Severe Coarctation of the Aorta: A Hybrid Approach to Treatment

    OpenAIRE

    McLennan, Daniel; Caputo, Massimo; Taliotis, Demetris

    2017-01-01

    Hybrid surgery is becoming more popular in the treatment of children with congenital heart disease, particularly small infants and neonates. We report a case of a patient with aortic stenosis (AS) and coarctation of the aorta (CoA). Case: a 1-month-old baby presented with severe AS and CoA. The decision was made to perform a hybrid surgical procedure. The patient underwent a lateral thoracotomy for repair of the CoA and carotid cutdown for aortic balloon valvuloplasty (AoVP).

  15. Valvoplastia aórtica por cateter-balão em emergência materno-fetal na adolescência Valvuloplastia aórtica por catéter con balón en emergencia materno-fetal en la adolescencia Aortic valvuloplasty with balloon catheter in maternal-fetal emergency in adolescence

    Directory of Open Access Journals (Sweden)

    Walkiria Samuel Avila

    2009-12-01

    Full Text Available O aumento do débito cardíaco durante a gravidez é causa de insuficiência cardíaca em portadoras de estenose valvar aórtica grave. A valvoplastia aórtica percutânea tem sido associada a graves complicações e reestenose valvar em curto prazo. O presente caso mostrou que a valvoplastia aórtica percutânea permitiu o alcance do parto com sobrevida da mãe e do feto, e que a interrupção do tratamento no pós-parto resultou em morte materna no puerpério tardio.El aumento del gasto cardiaco durante el embarazo es la causa de insuficiencia cardiaca en portadoras de estenosis valvular aórtica severa. Se viene asociando la valvuloplastia aórtica percutánea a severas complicaciones y reestenosis valvular en corto plazo. El presente caso reveló que la valvuloplastia aórtica percutánea permitió el alcance del parto con sobrevida de la madre y del feto, y que la interrupción del tratamiento en el postparto resultó en muerte materna en el puerperio tardío.The increase of cardiac output during pregnancy is the cause of heart failure in women with severe aortic valvular stenosis. Percutaneous aortic valvuloplasty has been associated with severe complications and short-term valvar restenosis. This case showed that percutaneous aortic valvuloplasty allowed both mother and fetus to survive after childbirth, and that postpartum treatment interruption resulted in maternal death in late postpartum care.

  16. PEBS - Positron Electron Balloon Spectrometer

    CERN Document Server

    von Doetinchem, P.; Kirn, T.; Yearwood, G.Roper; Schael, S.

    2007-01-01

    The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was needed to design a detector which could increase the existing data by more than a factor of 100. Using silicon photomultipliers for the readout of a scintillating fiber tracker and of an imaging electromagnetic calorimeter, the PEBS detector features a large geometrical acceptance of 2500 cm^2 sr for positrons, a total weight of 1500 kg and a power consumption of 600 W. The experiment is intended to measure cosmic ray particle spectra for a period of up to 20 days at an altitude of 40 km circulating the North or South Pole. A full Geant 4 simulation of the detector concept has been developed and key elements have been verified in a testbeam in October 2006 at CERN.

  17. Left ventricular apical ballooning syndrome

    International Nuclear Information System (INIS)

    Rahman, N.; Tai, J.; Soofi, A.

    2007-01-01

    The transient left ventricular apical ballooning syndrome, also known as Takotsubo cardiomyopathy, is characterized by transient left ventricular dysfunction in the absence of obstructive epicardial coronary disease. Although the syndrome has been reported in Japan since 1990, it is rare in other regions. Rapid recognition of the syndrome can modify the diagnostic and therapeutic attitude i.e. avoiding thrombolysis and performing catheterization in the acute phase. (author)

  18. Lifting options for stratospheric aerosol geoengineering: advantages of tethered balloon systems.

    Science.gov (United States)

    Davidson, Peter; Burgoyne, Chris; Hunt, Hugh; Causier, Matt

    2012-09-13

    The Royal Society report 'Geoengineering the Climate' identified solar radiation management using albedo-enhancing aerosols injected into the stratosphere as the most affordable and effective option for geoengineering, but did not consider in any detail the options for delivery. This paper provides outline engineering analyses of the options, both for batch-delivery processes, following up on previous work for artillery shells, missiles, aircraft and free-flying balloons, as well as a more lengthy analysis of continuous-delivery systems that require a pipe connected to the ground and supported at a height of 20 km, either by a tower or by a tethered balloon. Towers are shown not to be practical, but a tethered balloon delivery system, with high-pressure pumping, appears to have much lower operating and capital costs than all other delivery options. Instead of transporting sulphuric acid mist precursors, such a system could also be used to transport slurries of high refractive index particles such as coated titanium dioxide. The use of such particles would allow useful experiments on opacity, coagulation and atmospheric chemistry at modest rates so as not to perturb regional or global climatic conditions, thus reducing scale-up risks. Criteria for particle choice are discussed, including the need to minimize or prevent ozone destruction. The paper estimates the time scales and relatively modest costs required if a tethered balloon system were to be introduced in a measured way with testing and development work proceeding over three decades, rather than in an emergency. The manufacture of a tether capable of sustaining the high tensions and internal pressures needed, as well as strong winds, is a significant challenge, as is the development of the necessary pumping and dispersion technologies. The greatest challenge may be the manufacture and launch of very large balloons, but means have been identified to significantly reduce the size of such balloons or aerostats.

  19. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  20. Aortic Aneurysm Statistics

    Science.gov (United States)

    ... people with inherited connective tissue disorders, such as Marfan syndrome and Ehlers-Danlos syndrome, get thoracic aortic aneurysms. ... Smoking . Some inherited connective tissue disorders, such as Marfan syndrome and Ehlers-Danlos syndrome, can also increase your ...

  1. Aortic Valve Disease

    Science.gov (United States)

    ... It is then replaced with an artificial valve (prosthesis). There are two valve options for aortic valve ... place, the catheter will be withdrawn from your body through the original access point. Because not all ...

  2. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  3. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  4. Traumatic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Brianna Miner

    2016-09-01

    Full Text Available History of present illness: A 48-year-old male with unknown past medical history presents as a trauma after being hit by a car traveling approximately 25 miles per hour. On initial presentation, the patient is confused, combative, and not answering questions appropriately. The patient is hypotensive with a blood pressure of 68/40 and a heart rate of 50 beats per minute, with oxygen saturation at 96% on room air. FAST scan is positive for fluid in Morrison’s pouch, splenorenal space, and pericardial space. Significant findings: The initial chest x-ray showed an abnormal superior mediastinal contour (blue line, suggestive of a possible aortic injury. The CT angiogram showed extensive circumferential irregularity and outpouching of the distal aortic arch (red arrows compatible with aortic transection. In addition, there was a circumferential intramural hematoma, which extended through the descending aorta to the proximal infrarenal abdominal aorta (green arrow. There was also an extensive surrounding mediastinal hematoma extending around the descending aorta and supraaortic branches (purple arrows. Discussion: Traumatic aortic injury is a life-threatening event. The incidence of blunt thoracic aortic injury is low, between 1 to 2 percent of those patients with blunt thoracic trauma.1 However, approximately 80% of patients with traumatic aortic injury die at the scene.2 Therefore it is imperative to diagnose traumatic aortic injury in a timely fashion. The diagnosis can be difficult due to the non-specific signs and symptoms and other distracting injuries. Clinical suspicion should be based on the mechanism of the injury and the hemodynamic status of the patient. In any patient with blunt or penetrating trauma to the chest that is hemodynamically unstable, traumatic aortic injury should be on the differential. Chest x-ray can be used as a screening tool. A normal chest x-ray has a negative predictive value of approximately 97%. CTA chest is the

  5. Thoracoabdominal Aortic Aneurysms

    Directory of Open Access Journals (Sweden)

    Ali Azizzadeh

    2008-09-01

    Full Text Available Over the last 50 years, significant progress has been made in the surgical repair of thoracoabdominal aortic aneurysms (TAAA.  Improvements in perioperative care and surgical techniques have resulted in reductions in complication and mortality rates. Adjunctive use of distal aortic perfusion and cerebrospinal fluid drainage has been especially helpful, reducing the incidence of neurological deficits to 2.4%. Current research is aimed at improving organ preservation. This review focuses on the current diagnosis and management of TAAA.

  6. Magnetic resonance imaging of coarctation of the aorta and postoperative interrupted aortic arch

    Energy Technology Data Exchange (ETDEWEB)

    Kakizawa, Hideyuki; Tanaka, Takashi; Takada, Osamu; Nakayama, Shingo; Ogata, Hiroshi; Zuguchi, Masayuki (Tohoku Univ., Sendai (Japan). School of Medicine)

    1991-03-01

    ECG-gated MRI was performed at 1.5 T on 9 patients with coarctation of the aorta and restensis of the aorta after previous aortoplasty for coarctation of the aorta or interrupted aortic arch. The age of the patients ranged from 7 days to 3.3 years. MRI was more useful in assessing the severity of stenosis than echocardiography. Four patients had balloon dilation angioplasty for restenosis of the aorta. MRI was also useful in deciding the appropriate balloon size for angioplasty, and follow up after treatment. However, MRI could not always visualize the whole lesion in one slice, especially when the course of the aortic arch was not on the same plane. (author).

  7. The impact of aortic manipulation on neurologic outcomes after coronary artery bypass surgery: a risk-adjusted study.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Stamou, Sotiris C; Dullum, Mercedes K C; Hill, Peter C; Haile, Elizabeth; Boyce, Steven W; Bafi, Ammar S; Petro, Kathleen R; Corso, Paul J

    2004-11-01

    Cerebral embolization of atherosclerotic plaque debris caused by aortic manipulation during conventional coronary artery bypass grafting (CABG) is a major mechanism of postoperative cerebrovascular accidents (CVA). Off-pump CABG (OPCABG) reduces stroke rates by minimizing aortic manipulation. Consequently, the effect of different levels of aortic manipulation on neurologic outcomes after CABG surgery was examined. From January 1998 to June 2002, 7,272 patients underwent isolated CABG surgery through three levels of aortic manipulation: full plus tangential (side-biting) aortic clamp application (on-pump surgery; n = 4,269), only tangential aortic clamp application (OPCABG surgery; n = 2,527) or an "aortic no-touch" technique (OPCABG surgery; n = 476). A risk-adjusted logistic regression analysis was performed to establish the likelihood of postoperative stroke with each technique. Preoperative risk factors for stroke from the literature, and those found significant in a univariable model were used. A significant association for postoperative stroke correspondingly increasing with the extent of aortic manipulation was demonstrated by the univariable analysis (CVA incidence respectively increasing from 0.8% to 1.6% to a maximum of 2.2%, p < 0.01). In the logistic regression model, patients who had a full and a tangential aortic clamp applied were 1.8 times more likely to have a stroke versus those without any aortic manipulation (95% confidence interval: 1.15 to 2.74, p < 0.01) and 1.7 times more likely to develop a postoperative stroke than those with only a tangential aortic clamp applied (95% confidence interval: 1.11 to 2.48, p < 0.01). Aortic manipulation during CABG is a contributing mechanism for postoperative stroke. The incidence of postoperative stroke increases with increased levels of aortic manipulation.

  8. Titan Balloon Convection Model, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  9. Current trends of balloon laryngoplasty in Thailand.

    Science.gov (United States)

    Moungthong, Greetha; Bunbanjerdsuk, Sacarin; Wright, Nida; Sathavornmanee, Thanakrit; Setabutr, Dhave

    2017-06-01

    To describe the current trend in balloon laryngoplasty usage and experience by practicing otolaryngologists in Thailand. Anonymous 11 question online and paper survey of otolaryngologists on their current balloon laryngoplasty practices. Current practices and experience in balloon laryngoplasty were queried with multiple choice and open-ended questions. Laser use is the most commonly utilized instrument to treat airway stenosis in Thailand. 86% of respondents do not have experience with balloon dilatation; yet, almost half (47.6%) report they perform a minimum of five airway surgeries per year. Most respondents had been in practice for less than 6 years (41%) and reported that they did not have exposure to balloon use during residency training. The largest barrier reported for the use of balloon instrumentation in the airway is inexperience (44.4%) followed by cost (38.3%), yet most feel that treatment in airway stenosis could benefit by usage of balloons (95.5%). Most otolaryngologists in Thailand do not have experience with the use of balloon dilatation and lack of exposure remains the largest barrier to its use. Otolaryngologists in Thailand feel that increased usage of balloons in the airway could improve airway stenosis treatment in the country.

  10. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  11. CArbon dioxide surgical field flooding and aortic NO-touch off-pump coronary artery bypass grafting to reduce Neurological injuries after surgical coronary revascularisation (CANON): protocol for a randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms

    Science.gov (United States)

    Szwed, Krzysztof; Pawliszak, Wojciech; Serafin, Zbigniew; Kowalewski, Mariusz; Tomczyk, Remigiusz; Perlinski, Damian; Szwed, Magdalena; Tomaszewska, Marta; Anisimowicz, Lech; Borkowska, Alina

    2017-01-01

    Introduction Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. Methods and analysis In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethics and dissemination Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. Trial registration number NCT03074604; Pre-results. Date and version identifier 10-Mar-2017 Original PMID:28698347

  12. CArbon dioxide surgical field flooding and aortic NO-touch off-pump coronary artery bypass grafting to reduce Neurological injuries after surgical coronary revascularisation (CANON): protocol for a randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms.

    Science.gov (United States)

    Krzysztof, Szwed; Wojciech, Pawliszak; Zbigniew, Serafin; Mariusz, Kowalewski; Remigiusz, Tomczyk; Damian, Perlinski; Magdalena, Szwed; Marta, Tomaszewska; Lech, Anisimowicz; Alina, Borkowska

    2017-07-10

    Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. NCT03074604; Pre-results. 10-Mar-2017 Original. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Balloon dilatations of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Seoul (Korea, Republic of)

    1990-04-15

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used.

  14. Balloon dilatations of esophageal strictures

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De

    1990-01-01

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used

  15. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  16. Simulation of stratospheric balloon environment

    International Nuclear Information System (INIS)

    Sable, C.

    1974-01-01

    The behavior of materials used for the construction of stratospheric balloons is studied at DERTS by means of irradiations performed in reals time and simulating the exact flight environment. Two chambers were designed in the laboratory and are described together with the experimental procedure. In order to reduce cost and save time, it is worth accelerating the simulation when only a preliminary evaluation of the sample's properties is required. For this reason, a systematic study was undertaken in order to evaluate the respective effects of different parameters on the material degradation. The results of this study are given [fr

  17. Balloon dilatation of iatrogenic urethral strictures

    International Nuclear Information System (INIS)

    Acunas, B.; Acunas, G.; Gokmen, E.; Celik, L.

    1988-01-01

    Balloon dilatation of the urethra was performed in five patients with iatrogenic urethral strictures. The urethral strictures were successfully negotiated and dilated in all patients. Redilatation became necessary in a period ranging from 3 to 10 months. The authors believe that balloon dilatation of the urethra can be safely and successfully performed; the procedure produces minimal trauma and immediate relief of symptoms. (orig.)

  18. Percutaneous balloon dilatation for benign hepaticojejunostomy strictures

    NARCIS (Netherlands)

    Vos, P. M.; van Beek, E. J.; Smits, N. J.; Rauws, E. A.; Gouma, D. J.; Reeders, J. W.

    2000-01-01

    BACKGROUND: Percutaneous balloon dilatation of biliary tract strictures is generally accepted as a safe and inexpensive procedure. The effectiveness in selected groups of patients remains under discussion. The purpose of this study was to evaluate the results of percutaneous balloon dilatation in

  19. [Aortic arch advancement surgery as treatment for aortic coarctation with hypoplastic aortic arch in children].

    Science.gov (United States)

    Palacios-Macedo-Quenot, Alexis; Urencio, Miguel; Ponce-De-León-Rosales, Sergio; López-Terrazas, Javier; Castañuela-Sánchez, Violeta; March-Mifsut, Almudena; López-Magallón, Alejandro; Pérez-Juárez, Fabiola; Cedillo-Rendón, Irma; Tamariz-Cruz, Orlando

    2012-01-01

    Treatment of aortic coarctation with hypoplastic aortic arch is still a surgical challenge. The aortic arch advancement surgery has shown less re-coarctation frequency. To determine the re-coarctation frequency in patients who underwent aortic arch advancement technique for aortic coarctation with hypoplastic aortic arch and analyze the results. Retrospective and observational study of 38 patients who underwent aortic arch advancement in a third level Institution from 2002 to 2010. Twenty four males and 14 females all with aortic arch Z index diameter of coarctation was O%. With the previously mentioned technique the recoarctation frequency on medium and long term basis was 0%. From the anatomical and functional point of view, we believe this technique offers the best possible results.

  20. Early Cosmic Ray Research with Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Michael, E-mail: michael.walter@desy.de

    2013-06-15

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  1. Types of Breast Pumps

    Science.gov (United States)

    ... Devices Consumer Products Breast Pumps Types of Breast Pumps Share Tweet Linkedin Pin it More sharing options ... used for feeding a baby. Types of Breast Pumps There are three basic types of breast pumps: ...

  2. Transcatheter Aortic Valve Replacement With Different Valve Types in Elliptic Aortic Annuli.

    Science.gov (United States)

    Maeno, Yoshio; Abramowitz, Yigal; Yoon, Sung-Han; Jilaihawi, Hasan; Raul, Sharma; Israr, Sharjeel; Miyasaka, Masaki; Kawamori, Hiroyuki; Kazuno, Yoshio; Rami, Tanya; Takahashi, Nobuyuki; Mangat, Geeteshwar; Kashif, Mohammad; Chakravarty, Tarun; Nakamura, Mamoo; Cheng, Wen; Makkar, Raj R

    2017-06-23

    The aim of this study was to determine the influence of an elliptic annulus on acute device success rates following self-expanding (SE) transcatheter aortic valve replacement (TAVR) vs. balloon-expandable (BE) TAVR.Methods and Results:Outcomes were assessed using Valve Academic Research Consortium-2 definitions. Aortic annulus ratio (AAR) was measured as short axis diameter/long axis diameter. Mean AAR was 0.81±0.06. Patients were therefore divided into 2 groups: AAR elliptic annuli, SE-TAVR was an independent predictor of unsuccessful device implantation (OR, 6.34, Pelliptic annuli was associated with an exponential rise in device success (threshold ≥17.5%; area under the curve, 0.83) but not for BE-TAVR. Furthermore, optimally oversized SE valves and BE valves had a similarly high device success for elliptic annuli (SE valve, 96.2% vs. BE valve, 95.3%). For circular annuli, similarly high device success was achieved for the 2 valve types. Conversely, for elliptic annuli, SE valves had a lower device success than BE valves. Device success following optimal oversizing of SE valves, however, was similar to that for BE valves.

  3. Quadricuspid Aortic Valve Combined with Moderate Ascending Aortic Dilatation: A Report of Four Cases.

    Science.gov (United States)

    Uspenskiy, Vladimir E; Osadchii, Alexei M; Gordeev, Mikhail L

    2015-12-01

    The quadricuspid aortic valve is a very uncommon malformation associated with aortic insufficiency, aortic stenosis, endocarditis, and ascending aortic dilatation. We report four cases of this aortic valve malformation. One patient with severe aortic regurgitation and moderate aortic dilatation required aortic valve replacement. Three patients had mild or moderate aortic insufficiency combined with moderate ascending aortic dilatation. These patients were referred to follow-up. The presented cases demonstrate that this aortic valve malformation may not be as rare as it appears and that attention must be paid to any quadricuspid findings during computed tomographic angiography and echocardiography.

  4. Is Removal of the Pressure-regulating Balloon Necessary After Artificial Urinary Sphincter Cuff Erosion?

    Science.gov (United States)

    Rozanski, Alexander T; Viers, Boyd R; Shakir, Nabeel A; Pagliara, Travis J; Scott, Jeremy M; Morey, Allen F

    2018-03-01

    To characterize the risk of delayed infectious complications from retained pressure-regulating balloons (PRBs) after artificial urinary sphincter (AUS) cuff erosion. From our database of 530 AUS cases between 2007 and 2016, we identified 40 total AUS cuff erosions. Twenty-four (60%) presented without evidence of gross device infection and underwent explant of cuff and pump without removal of the PRB. Space of Retzius (SoR) and high submuscular (HSM) balloon locations were analyzed to assess for ease of removal. Presenting clinical features and retained balloon-related outcomes are reported. Of the 24 AUS cuff erosions with retained balloons, 6 (25%) men subsequently required PRB removal for infection during the median follow-up of 36 months (interquartile range 29-53). The median time to balloon infection after AUS erosion surgery was 4 months (interquartile range 4-16). Infection risk was reduced in those without concurrent inflatable penile prosthesis (20%) and in those who underwent "drain and retain" of the PRB (13%). The most common presenting clinical symptoms with retained PRB infection were pain and erythema near the site of the PRB (83%). No patient developed sepsis-related complications. The location of the PRB in this subcohort included 2 SoR and 4 HSM placements. The median operative time for balloon removal in the SoR was 3.5 times greater than that for HSM PRBs (133 minutes vs 38 minutes). With extended follow-up, three-quarters of the men with retained PRBs after AUS cuff erosion experienced no infectious complications. Removal of infected SoR PRBs was associated with greater operative times and surgical complexity relative to HSM PRBs. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Trajectory Control For High Altitude Balloons

    Science.gov (United States)

    Aaron, K.; Nock, K.; Heun, M.; Wyszkowski, C.

    We will discuss the continuing development of the StratoSailTM Balloon Trajectory Control System presented at the 33rd COSPAR in 2000. A vertical wing suspended on a 15-km tether from a high altitude balloon uses the difference in wind velocity between the altitude of the balloon and the altitude of the wing to create an aerodynamic sideforce. This sideforce, transmitted to the balloon gondola via the tether, causes the balloon to move laterally. Although the balloon's resultant drift velocity is quite small (a few meters per second), the effect becomes significant over long periods of time (hours to days). Recently, a full-scale wing, rudder and boom assembly has been fabricated, a winch system testbed has been completed, and a lightweight tether with reduced susceptibility to ultraviolet damage has been developed. The development effort for this invention, with pending international patents, has been funded by the NASA/SBIR program in support of the Ultra Long Duration Balloon (ULDB) program.

  6. Unoperated aortic aneurysm

    DEFF Research Database (Denmark)

    Perko, M J; Nørgaard, M; Herzog, T M

    1995-01-01

    From 1984 to 1993, 1,053 patients were admitted with aortic aneurysm (AA) and 170 (15%) were not operated on. The most frequent reason for nonoperative management was presumed technical inoperability. Survivals for patients with thoracic, thoracoabdominal, and abdominal AA were comparable. No sig...

  7. Double aortic arch

    Science.gov (United States)

    Surgery can be done to fix double aortic arch. The surgeon ties off the smaller branch and separates it from the larger branch. Then the surgeon closes the ends of the aorta with stitches. This relieves pressure on the esophagus and windpipe.

  8. Tissue engineered aortic valve

    OpenAIRE

    Dohmen, P M

    2012-01-01

    Several prostheses are available to replace degenerative diseased aortic valves with unique advantages and disadvantages. Bioprotheses show excellent hemodynamic behavior and low risk of thromboembolic complications, but are limited by tissue deterioration. Mechanical heart valves have extended durability, but permanent anticoagulation is mandatory. Tissue engineering created a new generation heart valve, which overcome limitations of biological and mechanical heart valves due to remodelling,...

  9. 14 CFR 61.115 - Balloon rating: Limitations.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Balloon rating: Limitations. 61.115 Section... rating: Limitations. (a) If a person who applies for a private pilot certificate with a balloon rating... operate a gas balloon. (b) If a person who applies for a private pilot certificate with a balloon rating...

  10. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  11. Abdominal cavity balloon for preventing a patient's bleeding

    NARCIS (Netherlands)

    Naber, E.E.H.; Rutten, H.J.T.; Jakimowicz, J.J.; Goossens, R.H.M.; Moes, C.C.M.; Buzink, S.N.

    2007-01-01

    The invention relates to an abdominal cavity balloon for preventing a haemorrhage in a patient's pelvic region, comprising an inflatable balloon, wherein the balloon is pro vided with a smooth surface and with a strip that is flex- urally stiff and formed to follow the balloon's shape for po

  12. Chimney Technique in Supra-Aortic Branch Reconstruction in China: A Systematic and Critical Review of Chinese Published Experience.

    Science.gov (United States)

    Zhao, Yang; Shi, Yawei; Wang, Mian; Cui, Jin; Chen, Yitian; Zheng, Liang; Yin, Henghui; Chang, Guangqi

    2017-08-01

    The chimney graft (CG) technique has been proposed as a complete endovascular supra-aortic branch reconstruction for aortic pathologies. Due to the rapid growth of thoracic endovascular aortic repair (TEVAR) in China, we aimed to investigate the current data of the CG technique in this most populous country. Studies of supra-aortic branch reconstruction using the CG technique from Chinese centers were collected and analyzed. A total of 294 patients from Chinese centers who underwent TEVAR with CGs were included. There were 301 CGs performed, with a technical successful rate of 97.7%. The rate of early type I endoleaks was 7.1%, and the patency rate of the CGs was desirable. Balloon-expandable bare CGs were significantly associated with good early outcomes and a low rate of endoleaks. Current data from China revealed positive outcomes using CGs for supra-aortic branch reconstruction. Balloon-expandable bare CGs may be the first choice according to the data available but should be considered with caution.

  13. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  14. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  15. A comparative study of internally and externally capped balloons using small scale test balloons

    Science.gov (United States)

    Bell, Douglas P.

    1994-01-01

    Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.

  16. Efficacy of a novel fluoroscopy-free endovascular balloon device with pressure release capabilities in the setting of uncontrolled junctional hemorrhage.

    Science.gov (United States)

    Sokol, Kyle K; Black, George E; Shawhan, Robert; Marko, Shannon T; Eckert, Matthew J; Tran, Nam T; Starnes, Benjamin W; Martin, Matthew J

    2016-06-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) has emerged as an alternative to gauze packing (GP) in the setting of noncompressible torso hemorrhage. Our objective was to describe placement and physiologic impact of a novel REBOA device during uncontrolled junctional hemorrhage. We hypothesized that REBOA could be deployed without fluoroscopic guidance or intra-aortic barotrauma and could increase survival in the setting of profound shock physiology. Fourteen adult swine (35-50 kg) underwent a hemorrhage and ischemia/reperfusion injury protocol to produce shock physiology and dilutional coagulopathy and randomized to REBOA (n = 8) or standard GP (n = 6) groups. A complex contralateral groin soft tissue and vascular injury was then created, followed by 30 seconds of free bleeding and GP for 5 minutes. The REBOA group had the aortic balloon inflated in aortic Zone III until the pressure release valve opened, followed by 45-minute postpacking survival, after which native and balloon-exposed aortae were harvested for histologic analysis. Control and REBOA groups had similar baseline hemodynamics (mean arterial pressure, 32 mm Hg vs. 43 mm Hg; p = 0.228), levels of coagulopathy (international normalized ratio, 1.3 vs. 1.2, p = 0.476; fibrinogen, 108 vs. 135 mg/dL, p = 0.747), and hemorrhage/ischemia/reperfusion insult (lactate, 7 vs. 7, p = 0.950; base deficit, 9 vs. 5, p = 0.491). No histologic barotrauma was identified, and 88% of the REBOA devices were successfully deployed into the Zone III of the aorta. The REBOA group had significantly decreased hemorrhage volumes (0.5 L vs. 0.2 L, p = 0.014) and increased survival times (45 minutes vs. 8 minutes, p the setting of noncompressible torso hemorrhage and is the first to show that this specific REBOA device can be blindly guided into the appropriate zone of the aorta without generating aortic wall injury during unmeasured balloon inflation.

  17. Balloon Occlusion of the Contralateral Iliac Artery to Assist Recanalization of the Ipsilateral Iliac Artery in Total Aortoiliac Occlusion: A Technical Note

    Directory of Open Access Journals (Sweden)

    Abdel Aziz A. Jaffan

    2013-01-01

    Full Text Available Endovascular recanalization of chronic total aortoiliac occlusion is technically challenging. Inability to reenter the true aortic lumen, following retrograde iliac recanalization, is one of the most common causes of failure. We describe a case of a total aortoiliac occlusion where balloon occlusion of the right common iliac artery, following its recanalization from a brachial approach, was used to facilitate antegrade recanalization of the occluded contralateral left common iliac artery.

  18. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Li, Jun; Dong, Lili; Wang, Chunsheng; Shu, Xianhong

    2016-05-01

    Aberrant flow pattern and congenital fragility bestows bicuspid aortic valve (BAV) with a propensity toward ascending aorta dilatation, aneurysm, and dissection. Whether isolated aortic valve replacement (AVR) can prevent further dilatation in BAV ascending aorta and what indicates concurrent aortic intervention in the case of valve operation remain controversial. From June 2006 to January 2009, patients with a BAV who underwent isolated AVR were consecutively included and categorized into aortic insufficiency (BAV-AI, n = 84) and aortic stenosis (n = 112) groups, and another population of patients with a tricuspid aortic valve with aortic insufficiency (n = 149) was also recruited during the same period for comparison of annual aortic dilatation rate and adverse aortic events after isolated AVR. With a median follow-up period of 72 months (interquartile range, 66 to 78 months), ascending aorta dilatation rates were faster in the BAV-AI group than the BAV plus aortic stenosis and tricuspid aortic valve with aortic insufficiency groups (both p regression analysis identified aortic insufficiency (hazard ratio, 3.7; 95% confidence interval, 1.2 to 11.1; p = 0.019) as an independent risk factor for adverse aortic events among patients with BAV in general, whereas preoperative ascending aortic diameter larger than 45 mm (hazard ratio, 13.8; 95% confidence interval, 3.0 to 63.3; p = 0.001) served as a prognostic indicator in the BAV-AI group. An aggressive policy of preventive aortic interventions seemed appropriate in patients with BAV-AI during AVR, and BAV phenotype presenting as either insufficiency or stenosis should be taken into consideration when contemplating optimal surgical strategies for BAV aortopathy. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    Science.gov (United States)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  20. Anaesthetic management for balloon dilation of cor triatriatum dexter in a dog.

    Science.gov (United States)

    De Monte, Valentina; Staffieri, Francesco; Caivano, Domenico; Bufalari, Antonello

    2015-06-10

    A three-month-old female Rottweiler puppy was referred for intravascular correction of a previously identified cor triatriatum dexter. Echocardiography confirmed the presence of a hyperechoic membrane that divided the right atrium into a cranial and caudal chamber. A foramen in this membrane allowed the blood to flow from the caudal to the cranial chamber. Balloon dilation of the defect under transthoracic echocardiographic guidance was scheduled for the following day. The dog was premedicated with 0.5 μg/kg sufentanil and 0.2 mg/kg midazolam administered intravenously. General anaesthesia was induced with 2 mg/kg propofol and maintained with inhaled isoflurane in oxygen; at the same time, a constant rate infusion of 0.5 μg/kg/h sufentanil was administered by means of an infusion pump. Uneventful ventricular and supraventricular tachyarrhythmias developed during the placement of catheters and balloon dilation. At the end of procedure, when the guide wire and balloon catheter were removed, normal sinus rhythm was observed. To the authors' knowledge, no previous reports have described the anaesthetic management of a balloon dilation procedure for cor triatriatum dexter in dogs.

  1. Computed tomography of aortic wall calcifications in aortic dissection patients.

    Directory of Open Access Journals (Sweden)

    Pim A de Jong

    Full Text Available To investigate the frequency of aortic calcifications at the outer edge of the false lumen and the frequency of fully circular aortic calcifications in a consecutive series of patients with aortic dissection who underwent contrast-enhanced CT.The study population compromised of 69 consecutive subjects aged 60 years and older with a contrast-enhanced CT scan demonstrating an aortic dissection. All CT scans were evaluated for the frequency of aortic calcifications at the outer edge of the false lumen and the frequency of fully circular aortic calcifications by two experienced observers. Between observer reliability was evaluated by using Cohen's Kappa. Differences between groups were tested using unpaired T test and Chi-square test.Presumed media calcifications were observed in 22 (32% patients of 60 years and older and were found more frequently in chronic aortic dissection (N = 12/23, 52% than in acute aortic dissection (N = 10/46, 22%.As the intima has been torn away by the aortic dissection it is highly likely that CT scans can visualize the calcifications in the tunica media of the aorta.

  2. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  3. Magnetometer for Balloons and UAVs Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR project will investigate a new, low-cost approach to atomic magnetometry that is suited for operation from UAVs and research balloons. Atomic...

  4. Solid State Inflation Balloon Active Deorbiter

    Data.gov (United States)

    National Aeronautics and Space Administration — The Solid State Inflation Balloon (SSIB) is a simple, reliable, low-cost, non-propulsive system for deliberate deorbit and control of downrange point-of-impact that...

  5. Shielded Mars Balloon Launcher (SMBL) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences, along with its partner Vertigo Industries, proposes a novel approach to deployment of balloon-based payloads into the Martian atmosphere....

  6. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  7. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  8. Test ventilation with smoke, bubbles, and balloons

    International Nuclear Information System (INIS)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs

  9. Significance of balloon pressure recording during angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zollikofer, C.L.; Salomonowitz, E.; Frick, M.P.; Castaneda-Zuniga, W.R.; Amplatz, K.; Bruehlmann, W.F.

    1985-05-01

    During angioplasty of artificial stenoses, atherosclerotic human cadaver arteries, and normal canine arteries, pressure and volume of the dilatation balloons were continuously recorded. We found that a sudden yield of a lesion corresponded to a sudden drop in the pressure curve and an increase of the balloon volume. Volume monitoring was insensitive, but pressure recording was very precise. Continuous pressure recording, using a non-compliant inflation system, correctly demonstrated small breaks and ruptures of atherosclerotic vessels, changes not seen on fluoroscopy.

  10. Aortic wrapping for stanford type A acute aortic dissection: short and midterm outcome.

    Science.gov (United States)

    Demondion, Pierre; Ramadan, Ramzi; Azmoun, Alexandre; Raoux, François; Angel, Claude; Nottin, Rémi; Deleuze, Philippe

    2014-05-01

    Conventional surgical treatment of Stanford type A acute aortic dissection (AAD) is associated with considerable in-hospital mortality. As regards very elderly or high-risk patients with type A AAD, some may meet the criteria for less invasive surgery likely to prevent the complications associated with aortic replacement. We have retrospectively analyzed a cohort of patients admitted to our center for Stanford type A AAD and having undergone surgery between 2008 and 2012. The outcomes of the patients having had an aortic replacement under cardiopulmonary bypass (group A) have been compared with the outcomes of the patients who underwent off-pump wrapping of the ascending aorta (group B). Among the 54 patients admitted for Stanford type A AAD, 15 with a mean age of 77 years [46 to 94] underwent wrapping of the aorta. Regarding the new standard European system for cardiac operative risk evaluation (EuroSCORE II), the median result in our group B patients was 10.47 [5.02 to 30.07]. In-hospital mortality was 12.80% in group A and 6.6% in group B (p=0.66). For patients who underwent external wrapping of the ascending aorta, follow-up mortality rate was 13.3% with a median follow-up of 15 months [range 0 to 47]. The gold standard in cases of Stanford type A AAD consists of emergency surgical replacement of the dissected ascending aorta. In some cases in which the aortic root is not affected a less invasive surgical approach consisting of wrapping the dissected ascending aorta can be suggested as an alternative. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta.

    Science.gov (United States)

    Okamoto, Eiji; Yano, Tetsuya; Miura, Hidekazu; Shiraishi, Yasuyuki; Yambe, Tomoyuki; Mitamura, Yoshinori

    2017-12-01

    We have developed various axial flow blood pumps to realize the concept of the Valvo pump, and we have studied hemodynamic changes under cardiac assistance using an axial flow blood pump in series with the natural heart. In this study, we measured hemodynamic changes of not only systemic circulation but also cerebral circulation and coronary circulation under cardiac support using our latest axial flow blood pump placed in the descending aorta in an acute animal experiment. The axial flow blood pump was installed at the thoracic descending aorta through a left thoracotomy of a goat (43.8 kg, female). When the pump was on, the aortic pressure and aortic flow downstream of the pump increased with preservation of pulsatilities. The pressure drop upstream of the pump caused reduction of afterload pressure, and it may lead to reduction of left ventricular wall stress. However, cerebral blood flow and coronary blood flow were decreased when the pump was on. The axial flow blood pump enables more effective blood perfusion into systemic circulation, but it has the potential risk of blood perfusion disturbance into cerebral circulation and coronary circulation. The results indicate that the position before the coronary ostia might be suitable for implantation of the axial flow blood pump in series with the natural heart to avoid blood perfusion disturbances.

  12. Hypoplasia of the aortic arch

    Directory of Open Access Journals (Sweden)

    Ю. С. Синельников

    2015-10-01

    Full Text Available An aggressive surgical approach to early repair of aortic coarctation and concomitant arch hypoplasia results in considerable improvement of the long-term outcomes of surgical treatment by reducing the number of aortic re-coarctation and arterial hypertension persistence events. At present, there exist some methods of determining the degree of aortic arch hypoplasia, which allow for arch reconstruction planning. Our review focuses on the analysis of modern methods of determination of the aortic arch hypoplasia and the outcomes of surgical treatment of this disease.

  13. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  14. Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients.

    Science.gov (United States)

    Haverich, Axel; Wahlers, Thorsten C; Borger, Michael A; Shrestha, Malakh; Kocher, Alfred A; Walther, Thomas; Roth, Matthias; Misfeld, Martin; Mohr, Friedrich W; Kempfert, Joerg; Dohmen, Pascal M; Schmitz, Christoph; Rahmanian, Parwis; Wiedemann, Dominik; Duhay, Francis G; Laufer, Günther

    2014-12-01

    Superior aortic valve hemodynamic performance can accelerate left ventricular mass regression and enhance survival and functional status after surgical aortic valve replacement. This can be achieved by rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame, which functionally widens and reshapes the left ventricular outflow tract, to ensure a larger effective orifice area compared with conventional surgical valves. We report the intermediate-term follow-up data from a large series of patients enrolled in the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial. In a prospective, multicenter (6 European hospitals), single-arm study, 287 patients with aortic stenosis underwent rapid deployment aortic valve replacement using a stented trileaflet bovine pericardial bioprosthesis. Core laboratory echocardiography was performed at baseline, discharge, and 3 months, 1 year, and 3 years after rapid deployment aortic valve replacement. The mean patient age was 75.7 ± 6.7 years (range, 45-93; 49.1% women). The mean aortic valve gradient significantly decreased from discharge to 3 years of follow-up. The mean effective orifice area remained stable from discharge to 3 years. At 1 year, the left ventricular mass index had decreased by 14% (P replacement using a subannular balloon-expandable stent frame demonstrated excellent hemodynamic performance and significant left ventricular mass regression. With continued follow-up, future studies will establish whether these favorable structural changes correlate with improvement in long-term survival and functional status. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Concomitant coronary artery bypass graft and aortic and mitral valve replacement for rheumatic heart disease: short- and mid-term outcomes.

    Science.gov (United States)

    Davarpasand, Tahereh; Hosseinsabet, Ali; Jalali, Arash

    2015-09-01

    It has been reported that the short-term mortality of concomitant aortic and mitral valve replacement (AVR and MVR) is considerable and concomitant coronary artery bypass graft (CABG) has adverse effects on the survival of patients with valve replacement surgery. We summarize the short- and mid-term outcome after concomitant CABG, AVR and MVR in our centre. Between 2003 and 2013, 103 patients (68 males, 35 females, age: 60.1 ± 10.1 years) underwent CABG, AVR and MVR for rheumatic heart disease (RHD) and coronary artery disease (CAD). The median follow-up was 47.6 months. Most of the patients were asymptomatic at rest. We analysed demographic, clinical and operative data of patients to define independent predictors of overall survival, cardiac event-free survival as well as cardiac death. The rate of 30-day survival was 93% (n = 96). The corresponding rates of overall survival and cardiac event-free survival and the cumulative incidence rate of cardiac death at 1 year were 80.2, 77.3 and 10.9%; the same at 4 years were 73.7, 64.6 and 15.8%. The corresponding freedom rates from anticoagulation-associated major haemorrhage; a composite of major bleeding events, thromboemboli and valvular thrombosis; cardiac rehospitalization; major adverse valve-associated events; and significant malfunction of the prosthetic valve were 96.2, 95.3, 94.7, 81.6 and 97.7% at 1 year. The corresponding freedom rates from anticoagulation-associated major haemorrhage; a composite of major bleeding events, thromboemboli and valvular thrombosis; cardiac rehospitalization; major adverse valve-associated events; and significant malfunction of the prosthetic valve were 93.5, 91.0, 91.4, 73.5 and 95.5% at 4 years. The independent predictors of overall survival were age, cigarette smoking, chronic kidney diseases and balloon pump insertion. The independent predictors of cardiac event-free survival were age and previous myocardial infarction, while age, cigarette smoking, history of cerebrovascular

  16. The adventitia layer modulates the arterial wall elastic response to intra-aortic counterpulsation: in vivo studies.

    Science.gov (United States)

    Cabrera-Fischer, Edmundo I; Bia, Daniel; Zócalo, Yanina; Wray, Sandra; Armentano, Ricardo

    2013-12-01

    There is a relationship between the intra-aortic balloon pumping (IABP) benefits and the dynamic behavior of muscular arteries, which is associated with induced changes on the vessel walls through an endothelial-dependent mechanism. The arterial wall elastic behavior is influenced by adventitial function; however, no studies were performed in order to elucidate if this layer plays a role in the changes determined by IABP. Our aim was to quantify acute IABP effects on the mechanical properties of muscular arteries in induced acute heart failure (AHF), before and after adventitia removal. Pressure and diameter were recorded in the iliac arteries (IA) of sheep (n = 7), before and during 1:2 IABP: (i) in control state (CS) with intact IA, (ii) in CS after IA adventitia removal, and (iii) in de-adventitialized IA after AHF. Conduit function, compliance and arterial distensibility were calculated in each state. During CS, IABP resulted in intact IA dilatation and in an increase in conduit function, compliance and distensibility; adventitial removal determined an increase of arterial stiffness with respect to the CS, which decreased when IABP was used; the increase in arterial stiffness observed after adventitia removal was also detected in AHF state; IABP improves conduit function and arterial stiffness in de-adventitialized arteries, both before and during AHF. However, the improvement in these properties was lower than in intact arteries. Before and after AHF induction, the improvements of conduit function and arterial distensibility determined by IABP in intact IA were significantly reduced after adventitia removal. Adventitial layer integrity would be necessary to maximize IABP-related beneficial effects on arterial system properties. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  17. Breastfeeding FAQs: Pumping

    Science.gov (United States)

    ... of pump is best? You can buy or rent a breast pump from lactation consultants, hospitals, retail ... place to do it. Many companies offer their employees pumping and nursing areas. If yours doesn't, ...

  18. [Coronary angioplasty using double balloon in artery of large calibre (hugging balloons)].

    Science.gov (United States)

    Centemero, M P; Cano, M N; Maldonado, G; de Almeida, J D; Sousa, A G; Sousa, J E

    1993-07-01

    In this case report the transluminal coronary angioplasty was performed in a oversized right coronary artery with a severe lesion with thrombus inside, using the Hugging balloon technique (two dilatation balloon catheters used simultaneously). This technique achieved minimal residual lesion and had a favorable clinical outcome of the patient.

  19. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  20. Helium pumping with liquid ring vacuum pump

    International Nuclear Information System (INIS)

    Mathy, C.; Gravil, B.; Sauvigne, G.; Verdier, J.

    1983-09-01

    At first the main principles for operation and building of liquid ring pumps are remembered and an experiment is described which allowed to assess the performance data of such pumps when used to pump helium gas with oil. Although they have been designed to pump air with water the adaptation for helium is rather simple, the input power is slightly higher in the same flow and pressure conditions, but the limit of the succion pressure is lowered [fr

  1. Liquid metal pump

    Science.gov (United States)

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  2. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair

  3. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  4. Different transcatheter strategies for aortic coarctation associated with patent ductus arteriosus

    Science.gov (United States)

    Singhi, Anil Kumar; Sivakumar, Kothandam

    2012-01-01

    Background Older patients with combination of aortic coarctation and large patent ductus arteriosus can be managed with transcatheter interventions. The strategies depend on anatomy of coarctation and size of ductus arteriosus. Methods We present three different patients with this combination. The anatomic factors like isthmic hypoplasia, dilatation of post coarctation descending aorta and size of ductus arteriosus were noted. Results Patients with isthmic hypoplasia needed stent angioplasty of the coarctation. If there is no dilatation of post coarctation aorta, a single covered stent excluded the ductus arteriosus and relieved the coarctation gradients. Dilated post coarctation aorta precluded a covered stent and warranted closure of duct with occluder device and stent angioplasty of coarctation. When there is a good sized aortic isthmus in a discrete membranous coarctation, device closure of the duct and balloon aortoplasty was successful. Conclusions In coarctation with patent ductus arteriosus associated with good sized aortic isthmus, closure of duct with duct occluder device and balloon aortoplasty would correct the lesions. If there is isthmic hypoplasia, device closure of the duct and stenting of the coarctation is needed. Covered stent is a reasonable alternative only in presence of non dilated descending aorta. PMID:22929832

  5. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch

    DEFF Research Database (Denmark)

    Millan-Iturbe, Oscar; Sawaya, Fadi J.; Bieliauskas, Gintautas

    2017-01-01

    AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a “gothic aortic arch”; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled...

  6. Aortic dissection with acute malperfusion syndrome: Endovascular fenestration via the funnel technique.

    Science.gov (United States)

    Vendrell, Anne; Frandon, Julien; Rodiere, Mathieu; Chavanon, Olivier; Baguet, Jean-Philippe; Bricault, Ivan; Boussat, Bastien; Ferretti, Gilbert Raymond; Thony, Frédéric

    2015-07-01

    To analyze the short- and long-term results of an original aortic fenestration method using the funnel technique during aortic dissection complicated by malperfusion syndrome. The funnel technique consists of deployment of an uncovered aortic stent graft placed from the false to the right lumen through an intimal flap aortic fenestration made by balloon angioplasty. Twenty-eight patients presenting with an aortic dissection (type A, n = 19; type B, n = 9) were treated for malperfusion syndrome owing to dynamic compression (16 renal, 17 bowel, and 13 lower limb ischemia) using the aforementioned technique, and had follow-up evaluation at short term (30 days) and long term (mean: 55 ± 40 months). Eight patients had severe ischemia on arrival (6 bowel, 7 renal, 3 lower limb). Technical success was achieved in 27 of 28 patients (96%), and ischemic symptoms had disappeared in 25 of 28 patients (89%) at short-term follow up. Five patients presented postprocedure complications: 4 minor and 1 major with arterial thrombosis which caused technical failure (3.6%). The 30-day mortality rate was 7% (n = 2), related to bowel ischemia complications. At long-term follow up, 21 patients had a stable thoracic aortic diameter (91%). The funnel technique, in cases of malperfusion syndrome after aortic dissection, safely improves short- and long-term clinical outcome, and could represent an interesting alternative in the management of patients. The hemodynamic efficiency of this technique may account for a lower mortality in our series. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  7. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome.

    Science.gov (United States)

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-12-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitation and chronic descending aortic dissection immediately after Cesarean section. Regular follow-up will be needed to monitor the descending aortic dissection.

  8. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  9. Uso do balão intra-aórtico no trans e pós-operatório de cirurgia cardíaca: análise de 80 casos consecutivos Use of intra-aortic balloon pump in cardiac surgery: analysis of 80 consecutive cases

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2012-06-01

    Full Text Available FUNDAMENTO: A síndrome de baixo débito cardíaco no perioperatório de cirurgia cardíaca pode incidir em cerca de 10 a 15% dos pacientes; desse total, 2% necessitam de suporte mecânico para adequado controle hemodinâmico. OBJETIVOS: Descrever a mortalidade de pacientes que necessitaram utilizar balão intra-aórtico (BIAo no trans ou pós-operatório de cirurgia cardíaca, identificando variáveis pré-operatórias associadas a pior desfecho, assim como descrever as complicações pós-operatórias e a sobrevida em médio prazo. MÉTODOS: Estudo de coorte retrospectivo incluindo 80 casos consecutivos entre janeiro/2009 e setembro/2011. Os pacientes possuíam, em média, 62,9 ± 11,3 anos e 58,8% eram do sexo masculino. Na amostra, 81,3% dos pacientes eram hipertensos, 50% tinham infarto do miocárdio prévio e 38,8%, insuficiência cardíaca NYHA III/IV. A principal cirurgia realizada foi a revascularização miocárdica isolada (37,5%. RESULTADOS:A mortalidade hospitalar nesta série foi de 53,8% (IC95%: 42,7-64,9, sendo o tempo de isquemia > 90 minutos preditor independente de mortalidade em análise multivariada (RR 1,52 IC95%: 1,04-2,22. Em relação às complicações, 71,3% (IC95%: 61,2-81,4 dos pacientes apresentaram ao menos uma complicação adicional no período perioperatório, sendo a isquemia do membro inferior observada em 5% dos pacientes. A sobrevida em 1 ano foi de 43,6%, observando-se um platô na curva de sobrevida após uma queda acentuada inicial, relacionada à mortalidade hospitalar. CONCLUSÕES: Os pacientes que necessitam do BIAo compõem um grupo de muito alto risco para morbidade e mortalidade; seu emprego, entretanto, permite recuperar muitos pacientes de uma evolução que seria invariavelmente fatal, tendo os pacientes com alta hospitalar uma boa sobrevida em médio prazo.BACKGROUND: About 10% to 15% of patients undergoing cardiac surgery may develop low cardiac output syndrome in the perioperative period; of this total, 2% require mechanical support for adequate hemodynamic control. OBJECTIVE: To describe the mortality rates of patients who required the use of IABP in the perioperative or postoperative period of cardiac surgery, identifying preoperative variables associated with a worse outcome, as well as to describe the postoperative complications and medium-term survival. METHODS: Retrospective cohort study including 80 consecutive cases between January/2009 and September/ 2011. The patients had on average 62.9 ± 11.3 years and 58.8% were male; 81.3% were hypertensive, 50.0% had prior myocardial infarction and 38.8% has NYHA III/IV heart failure. The mainsurgery performed was isolated coronary artery bypass grafting (37.5%. RESULTS: Hospital mortality was 53.8% (IC 95%: 42.7-64.9, and cross-clamp time > 90 minutes was an independent predictor of mortality in multivariate analysis (OR 1.52 CI 95%: 1.04-2.22. 71.3% of patients (CI 95%: 61.2-81.4 had at least one additional complication in the perioperative period, with lower limb ischemia observed in 5.0% patients. One-year survival was 43.6%, with a plateau in survival rates after a sharp initial drop, related to hospital mortality. CONCLUSION: Patients who require IABP comprise a group of very high risk for morbidity and mortality. IABP use, however, enables the recovery of many patients from an evolution that would invariably be fatal, and patients discharged from hospital have a good medium-term survival.

  10. CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI)-predictive value and optimal thresholds for major anatomic parameters.

    Science.gov (United States)

    Schwarz, Florian; Lange, Philipp; Zinsser, Dominik; Greif, Martin; Boekstegers, Peter; Schmitz, Christoph; Reiser, Maximilian F; Kupatt, Christian; Becker, Hans C

    2014-01-01

    To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI) and to calculate optimal cutoff values for the selection of various prosthesis sizes. The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67). In the remaining 351 patients, the CoreValve (Medtronic) and the Edwards Sapien XT valve (Edwards Lifesciences) were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values. Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p'sprosthesis size for both manufacturers (multi-class AUC's: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89). Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases. CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.

  11. CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI-predictive value and optimal thresholds for major anatomic parameters.

    Directory of Open Access Journals (Sweden)

    Florian Schwarz

    Full Text Available BACKGROUND/OBJECTIVES: To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI and to calculate optimal cutoff values for the selection of various prosthesis sizes. METHODS: The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67. In the remaining 351 patients, the CoreValve (Medtronic and the Edwards Sapien XT valve (Edwards Lifesciences were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values. RESULTS: Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p's<0.05. Furthermore, mean diameter, annulus area and circumference had equally high predictive value for prosthesis size for both manufacturers (multi-class AUC's: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89. Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases. CONCLUSION: CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.

  12. Impeller-pump model derived from conservation laws applied to the simulation of the cardiovascular system coupled to heart-assist pumps.

    Science.gov (United States)

    Shi, Yubing; Korakianitis, Theodosios

    2018-02-01

    Previous numerical models of impeller pumps for ventricular assist devices utilize curve-fitted polynomials to simulate experimentally-obtained pressure difference versus flow rate characteristics of the pumps, with pump rotational speed as a parameter. In this paper the numerical model for the pump pressure difference versus flow rate characteristics is obtained by analytic derivation. The mass, energy and angular momentum conservation laws are applied to the working fluid passing through the impeller geometry and coupled with the turbomachine's velocity diagram. This results in the construction of a pressure difference versus flow rate characteristic for the specific pump geometry, with pump rotational speed as parameter. Overall this model allows modifications of the pump geometry, so that the pump avoids undesirable operating conditions, such as regurgitant flow. The HeartMate III centrifugal pump is used as an example to demonstrate the application of the technique. The parameterised numerical model for HeartMate III derived by this technique is coupled with a numerical model for the human cardiovascular system, and the combination is used to investigate the cardiovascular response under different conditions of impeller pump support. Conditions resulting in regurgitant pump flow, the pump resulting in aortic valve closure and taking over completely the pumping action from the diseased heart, and inner ventricular wall suction at pump inlet are predicted by the model. The simulation results suggest that for normal HeartMate III operation the pump speed should be maintained between 3,100 and 4,500 rpm to avoid regurgitant pump flow and ventricular suction. To obtain optimal overall cardiovascular system plus pump response, the pump operating speed should be 3,800 rpm. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Posttraumatic abdominal aortic dissection

    International Nuclear Information System (INIS)

    Hahmann, M.; Richter, G.M.; Kauffmann, G.W.; Schuhmacher, H.; Allenberg, J.R.

    2001-01-01

    Dissections due to deceleration trauma are rarely limited to the infradiaphragmal aorta (only 2-3%) and are usually lethal. Here we report the unusual course of an abdominal aortic dissection with aneurysmatic enlargement of the false lumen. Based on diagnostic imaging, a therapeutic stent application was planed in order to close the entry and to prevent rupture. During the intervention sondation of the false lumen revealed that the left renal artery had a reentry. Due to the complexity of the entry - reentry situation of the left renal artery the intervention was not possible, and the patient had to undergo vascular surgery. (orig.) [de

  14. Abdominal aortic aneurysm surgery

    DEFF Research Database (Denmark)

    Gefke, K; Schroeder, T V; Thisted, B

    1994-01-01

    The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 553......, 78% stated that their quality of life had improved or was unchanged after surgery and had resumed working. These data justify a therapeutically aggressive approach, including ICU therapy following AAA surgery, despite failure of one or more organ systems....

  15. Abdominal Aortic Emergencies.

    Science.gov (United States)

    Lech, Christie; Swaminathan, Anand

    2017-11-01

    This article discusses abdominal aortic emergencies. There is a common thread of risk factors and causes of these diseases, including age, male gender, hypertension, dyslipidemia, and connective tissue disorders. The most common presenting symptom of these disorders is pain, usually in the chest, flank, abdomen, or back. Computed tomography scan is the gold standard for diagnosis of pathologic conditions of the aorta in the hemodynamically stable patient. Treatment consists of a combination of blood pressure and heart rate control and, in many cases, emergent surgical intervention. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome

    OpenAIRE

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-01-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitat...

  17. Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation

    Directory of Open Access Journals (Sweden)

    Karel Van Praet

    2015-07-01

    Full Text Available Aortic regurgitation and dilatation of the aortic root and ascending aorta are severe complications of acromegaly. The current trend for management of an aortic root aneurysm is valve-sparing root replacement as well as restoring the diameter of the aortic sinotubular junction (STJ and annulus. Our case report supports the recommendation that in patients with acromegaly, severe aortic root involvement may indicate the need for surgery.

  18. Discussion on the Timing of Balloon Occlusion of the Abdominal Aorta during a Caesarean Section in Patients with Pernicious Placenta Previa Complicated with Placenta Accreta

    Science.gov (United States)

    Yang, Kaili; Cai, Lina

    2017-01-01

    Objective This paper is aimed at investigating the role and value of the timing of balloon occlusion of the abdominal aorta during caesarean section in patients with pernicious placenta previa complicated with placenta accreta. Methods 79 cases admitted to the Second Affiliated Hospital of Zhengzhou University from September 2015 to December 2016 were treated with ultrasound mediated abdominal aortic balloon occlusion. Among them, 42 cases, whose balloon occlusion time was selected before the delivery and transverse incision was taken, were group A. The other 37 cases were group B, whose timing of balloon occlusion was selected after the delivery and the uterine incision made trying to avoid the placenta or double incisions. The intraoperative blood loss, utilization of blood, and other indicators were compared between the two groups. Results The intraoperative blood loss in groups A and B was 413.8 ± 105.9 ml and 810.3 ± 180.3 ml, and the utilization of blood products in groups A and B was 30.23% and 89.2%. The total hysterectomy rate was 2.53% (2/79), with no hysterectomies in groups A and 2 cases in group B. Conclusion The balloon occlusion of the abdominal aorta before the delivery combined with a transverse incision is more effective. PMID:29230417

  19. Advanced Onboard Energy Storage Solution for Balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced Balloon Programs at NASA are looking for a potential 100 day missions at mid-altitudes. These balloons would be powered by solar panels to take advantage of...

  20. Crash in Australian outback ends NASA ballooning season

    Science.gov (United States)

    Harris, Margaret

    2010-06-01

    NASA has temporarily suspended all its scientific balloon launches after the balloon-borne Nuclear Compton Tele scope (NCT) crashed during take-off, scattering a trail of debris across the remote launch site and overturning a nearby parked car.

  1. Transcatheter Aortic Valve Replacement Versus Aortic Valve Bypass: A Comparison of Outcomes and Economics.

    Science.gov (United States)

    Brown, John W; Boyd, Jack H; Patel, Parth M; Baker, Mary L; Syed, Amjad; Ladowski, Joe; Corvera, Joel

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) is currently offered to patients who are high-risk candidates for conventional surgical aortic valve replacement. For the past 37 years, off-pump aortic valve bypass (AVB) has been used in elderly patients at our center for this similarly high-risk group. Although TAVR and AVB were offered to similar patients at our center, comparisons of clinical outcomes and hospital economics for each strategy were not reported. We reviewed the clinical and financial records of 53 consecutive AVB procedures performed since 2008 with the records of 51 consecutive TAVR procedures performed since 2012. Data included demographics, hemodynamics, The Society of Thoracic Surgeons (STS) risk score, extent of coronary disease, and ventricular function. Follow-up was 100% in both groups. Hospital financial information for both cohorts was obtained. Mean risk score for the TAVR group was 10.1% versus 17.6% for AVB group (p < 0.001). Kaplan-Meier hospital rates of 3- and 6-month survival and of 1-year survival were 88%, 86%, 81%, and 61% and 89%, 83%, 83%, and 70% for the TAVR and AVB groups, respectively (p = 0.781). Two patients who had undergone TAVR had a procedure-related stroke. The one stroke in an AVB recipient was late and not procedure related. At discharge, mild and moderate perivalvular and central aortic insufficiency were present in 31% and 16% of TAVR recipients, respectively; no AVB valve leaked. Transvalvular gradients were reduced to less than 10 mm Hg in both groups. The average hospital length of stay for the AVB-treated patients was 13 days, and it was 9 days for the TAVR-treated patients. Median hospital charges were $253,000 for TAVR and $158,000 for AVB. Mean payment to the hospital was $65,000 (TAVR) versus $64,000 (AVB), and the mean positive contribution margin (profit) to the hospital was $14,000 for TAVR versus $29,000 for AVB. TAVR and AVB relieve aortic stenosis and have similar and acceptable procedural mortality

  2. Spectrum of ballooning instabilities in a stellarator

    International Nuclear Information System (INIS)

    Cooper, W.A.; Singleton, D.B.; Dewar, R.L.

    1995-08-01

    The recent revival of interest in the application of the 'ballooning formalism' to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs

  3. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  4. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  5. Aortic elasticity and size are associated with aortic regurgitation and left ventricular dysfunction in tetralogy of Fallot after pulmonary valve replacement

    NARCIS (Netherlands)

    Grotenhuis, H.B.; Ottenkamp, J.; de Bruijn, L.; Westenberg, J.J.M.; Vliegen, H.W.; Kroft, L.J.M.; de Roos, A.

    2009-01-01

    Background: Aortic wall pathology and concomitant aortic dilatation have been described in tetralogy of Fallot (TOF) patients, which may negatively affect aortic valve and left ventricular systolic function. Objective: To assess aortic dimensions, aortic elasticity, aortic valve competence and

  6. Reinforced aortic root reconstruction for acute type A aortic dissection involving the aortic root

    Directory of Open Access Journals (Sweden)

    Han Qing-qi

    2013-06-01

    Full Text Available OBJECTIVE: There are debates regarding the optimal approach for AAAD involving the aortic root. We described a modified reinforced aortic root reconstruction approach for treating AAAD involving the aortic root. METHODS: A total of 161 patients with AAAD involving the aortic root were treated by our modified reinforced aortic root reconstruction approach from January 1998 to December 2008. Key features of our modified approach were placement of an autologous pericardial patch in the false lumen, lining of the sinotubular junction lumen with a polyester vascular ring, and wrapping of the vessel with Teflon strips. Outcome measures included post-operative mortality, survival, complications, and level of aortic regurgitation. RESULTS: A total of 161 patients were included in the study (mean age: 43.3 1 15.5 years. The mean duration of follow-up was 5.1 1 2.96 years (2-12 years. A total of 10 (6.2% and 11 (6.8% patients died during hospitalization and during follow-up, respectively. Thirty-one (19.3% patients experienced postoperative complications. The 1-, 3-, 5-, and 10-year survival rates were 99.3%, 98%, 93.8%, and 75.5%, respectively. There were no instances of recurrent aortic dissection, aortic aneurysm, or pseudoaneurysm during the entire study period. The severity of aortic regurgitation dramatically decreased immediately after surgery (from 28.6% to 0% grade 3-4 and thereafter slightly increased (from 0% to 7.2% at 5 years and 9.1% at 10 years. CONCLUSION: This modified reinforced aortic root reconstruction was feasible, safe and durable/effective, as indicated by its low mortality, low postoperative complications and high survival rate.

  7. Aortic root replacement after previous surgical intervention on the aortic valve, aortic root, or ascending aorta.

    Science.gov (United States)

    Kirsch, E W Matthias; Radu, N Costin; Mekontso-Dessap, Armand; Hillion, Marie-Line; Loisance, Daniel

    2006-03-01

    Aortic root replacement after a previous operation on the aortic valve, aortic root, or ascending aorta remains a major challenge. Records of 56 consecutive patients (44 men; mean age, 56.4 +/- 13.6 years) undergoing reoperative aortic root replacement between June 1994 and June 2005 were reviewed retrospectively. Reoperation was performed 9.4 +/- 6.7 years after the last cardiac operation. Indications for reoperation were true aneurysm (n = 14 [25%]), false aneurysm (n = 10 [18%]), dissection or redissection (n = 9 [16%]), structural or nonstructural valve dysfunction (n = 10 [18%]), prosthetic valve-graft infection (n = 12 [21%]), and miscellaneous (n = 1 [2%]). Procedures performed were aortic root replacement (n = 47 [84%]), aortic root replacement plus mitral valve procedure (n = 5 [9%]), and aortic root replacement plus arch replacement (n = 4 [7%]). In 14 (25%) patients coronary artery bypass grafting had to be performed unexpectedly during the same procedure or immediately after the procedure to re-establish coronary perfusion. Hospital mortality reached 17.9% (n = 10). Multivariate logistic regression analysis revealed the need for unplanned perioperative coronary artery bypass grafting as the sole independent risk factor for hospital death (P = .005). Actuarial survival was 83.8% +/- 4.9% at 1 month, 73.0% +/- 6.3% at 1 year, and 65.7% +/- 9.0% at 5 years after the operation. One patient had recurrence of endocarditis 6.7 months after the operation and required repeated homograft aortic root replacement. Reoperative aortic root replacement remains associated with a high postoperative mortality. The need to perform unplanned coronary artery bypass grafting during reoperative aortic root replacement is a major risk factor for hospital death. The optimal technique for coronary reconstruction in this setting remains to be debated.

  8. Performance of the EUSO-Balloon electronics

    International Nuclear Information System (INIS)

    Barrillon, P.; Dagoret, S.; Miyamoto, H.; Moretto, C.; Bacholle, S.; Blaksley, C; Gorodetzky, P.; Jung, A.; Prévôt, G.; Prat, P.; Bayer, J.; Blin, S.; Taille, C. De La; Cafagna, F.; Fornaro, C.; Karczmarczyk, J.; Tanco, G. Medina; Osteria, G.; Perfetto, F.; Park, I.

    2016-01-01

    The 24th of August 2014, the EUSO-Balloon instrument went for a night flight for several hours, 40 km above Timmins (Canada) balloon launching site, concretizing the hard work of an important part of the JEM-EUSO collaboration started 3 years before. This instrument consists of a telescope made of two lenses and a complex electronic chain divided in two main sub-systems: the PDM (Photo Detector Module) and the DP (Data Processor). Each of them is made of several innovative elements developed and tested in a short time. This paper presents their performances before and during the flight

  9. Exponential Growth of Nonlinear Ballooning Instability

    International Nuclear Information System (INIS)

    Zhu, P.; Hegna, C. C.; Sovinec, C. R.

    2009-01-01

    Recent ideal magnetohydrodynamic (MHD) theory predicts that a perturbation evolving from a linear ballooning instability will continue to grow exponentially in the intermediate nonlinear phase at the same linear growth rate. This prediction is confirmed in ideal MHD simulations. When the Lagrangian compression, a measure of the ballooning nonlinearity, becomes of the order of unity, the intermediate nonlinear phase is entered, during which the maximum plasma displacement amplitude as well as the total kinetic energy continues to grow exponentially at the rate of the corresponding linear phase.

  10. Aortic stenosis: An update.

    Science.gov (United States)

    Nathaniel, Sangeetha; Saligram, Shreyas; Innasimuthu, Antony Leslie

    2010-06-26

    Aortic stenosis (AS) is the most common valvular heart disease in the world. It is a disease of the elderly and as our population is getting older in both the developed and the developing world, there has been an increase in the prevalence of AS. It is impacting the mortality and morbidity of our elderly population. It is also causing a huge burden on the healthcare system. There has been tremendous progress in our understanding of AS in recent years. Lately, studies have shown that AS is not just a disease of the aortic valve but it affects the entire systemic vasculature. There are studies looking at more sophisticated measures of disease severity that might better predict the optimal timing of valve replacement. The improvement in our understanding in etiology and pathophysiology of the disease process has led to a number of trials with possible treatment options for AS. In this review, we talk about our understanding of the disease and latest developments in disease assessment and management. We look forward to a time when there will be medical treatment for AS.

  11. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  12. Outcomes of intragastric balloon placements in a private practice setting

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth M. H.; Alders, Peter R. H.; Chuttani, Ram; Scherpenisse, Joost

    2015-01-01

    Intragastric balloons are used as a treatment for obesity. Much of the data collected on balloons has been in the context of clinical trials in academic medical centers or as a bridge to bariatric surgery in obesity centers. The aim of this study was to investigate the efficacy and safety of balloon

  13. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  14. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge G; Grønbæk, Morten

    2012-01-01

    BACKGROUND: We determined the predictive power of tobacco smoking on aortic aneurysm as opposed to other risk factors in the general population. METHODS: We recorded tobacco smoking and other risk factors at baseline, and assessed hospitalization and death from aortic aneurysm in 15,072 individuals...... aneurysm in males and females consuming above 20g tobacco daily was 3.5% and 1.3%, among those >60years with plasma cholesterol >5mmol/L and a systolic blood pressure >140mmHg. CONCLUSIONS: Tobacco smoking is the most important predictor of future aortic aneurysm outcomes in the general population...

  15. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...... pump as mentioned above, thereby acting to generate a fluid flow through the tube upon repeated deformation of the tube between the two valve members. The pump element may comprise a connecting part for coupling to another tube and may comprise a sealing part establishing a fluid tight connection...

  16. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 is pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump

  17. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump. 13 refs., 5 figs., 1 tab

  18. Psychological consequences of screening for abdominal aortic aneurysm and conservative treatment of small abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Vammen, Sten; Fasting, H

    2000-01-01

    To describe the potential psychological consequences of screening for abdominal aortic aneurysms (AAAs).......To describe the potential psychological consequences of screening for abdominal aortic aneurysms (AAAs)....

  19. Adsorption pump for helium pumping out

    International Nuclear Information System (INIS)

    Donde, A.L.; Semenenko, Yu.E.

    1981-01-01

    Adsorption pump with adsorbent cooling by liquid helium is described. Shuttered shield protecting adsorbent against radiation is cooled with evaporating helium passing along the coil positioned on the shield. The pump is also equipped with primed cylindrical shield, cooled with liquid nitrogen. The nitrogen shield has in the lower part the shuttered shield, on the pump casing there is a valve used for pump pre-burning, and valves for connection to recipient as well. Pumping- out rates are presented at different pressures and temperatures of adsorbent. The pumping-out rate according to air at absorbent cooling with liquid nitrogen constituted 5x10 -4 Pa-3000 l/s, at 2x10 -2 Pa-630 l/s. During the absorbent cooling with liquid hydrogen the pumping-out rate according to air was at 4x10 -4 Pa-580 l/s, at 2x10 -3 Pa-680 l/s, according to hydrogen - at 8x10 -5 Pa-2500 l/s, at 5x10 -3 Pa-4200 l/s. During adsorbent cooling with liquid helium the rate of pumping-out according to hydrogen at 3x10 5 Pa-2400% l/s, at 6x10 3 Pa-1200 l/s, and according to helium at 3.5x10 -5 Pa-2800 l/s, at 4x10 -3 Pa-1150 l/s. The limit vacuum is equal to 1x10 -7 Pa. The volume of the vessel with liquid helium is equal to 3.5 l. Helium consumption is 80 cm 3 /h. Consumption of liquid nitrogen from the shield is 400 cm 3 /h. The limit pressure in the pump is obtained after forevacuum pumping-out (adsorbent regeneration) at 300 K temperature. The pump is made of copper. The pump height together with primed tubes is 800 mm diameter-380 mm [ru

  20. Fasting and meal-suppressed ghrelin levels before and after intragastric balloons and balloon-induced weight loss

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; Eichenberger, R. I.

    2014-01-01

    Intragastric balloons may be an option for obese patients with weight loss failure. Its mode of action remains enigmatic. We hypothesised depressed fasting ghrelin concentrations and enhanced meal suppression of ghrelin secretion by the gastric fundus through balloon contact and balloon-induced

  1. Aortic root geometry in aortic stenosis patients (a SEAS substudy)

    DEFF Research Database (Denmark)

    Bahlmann, Edda; Nienaber, Christoph A; Cramariuc, Dana

    2011-01-01

    with asymptomatic AS (mean age 67 years, 39% women) in the Simvastatin Ezetimibe in AS study were used. The inner aortic diameter was measured at four levels: annulus, sinus of Valsalva, sinotubular junction and supracoronary, and sinus height as the annulo-junctional distance. Analyses were based on vendor...... diameters (all P SEAS study, 27% of women and 19% of men did not have aortic root geometry fulfilling current requirements for TAVI....

  2. Suprarenal fixation resulting in intestinal malperfusion after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Siani, Andrea; Accrocca, Federico; De Vivo, Gennaro; Marcucci, Giustino

    2016-05-01

    Superior mesenteric artery (SMA) and coeliac axis (CA) occlusion after endovascular abdominal aneurysm aortic repair (EVAR-AAA), using endograft with suprarenal fixation, are uncommon. However, we are reporting a case of visceral malperfusion, which occurred 7 days after successful EVAR with suprarenal fixation for symptomatic AAA. Endograft metal stent barbs caused severe stenosis of SMA and CA. A successful recovery of SMA was carried out by means of a balloon-expandable stent released through bare metal stent barbs. We believe that an unfavourable anatomy of a proximal aortic neck and visceral aorta may have caused a wrong stent strut deployment with the coverage of CA and SMA. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. The murine angiotensin II-induced abdominal aortic aneurysm model: rupture risk and inflammatory progression patterns

    Directory of Open Access Journals (Sweden)

    Richard Y Cao

    2010-07-01

    Full Text Available An abdominal aortic aneurysm (AAA is an enlargement of the greatest artery in the body defined as an increase in diameter of 1.5-fold. AAAs are common in the elderly population and thousands die each year from their complications. The most commonly used mouse model to study the pathogenesis of AAA is the angiotensin II (Ang II infusion method delivered via osmotic mini-pump for 28 days. Here, we studied the site-specificity and onset of aortic rupture, characterized three-dimensional (3D images and flow patterns in developing AAAs by ultrasound imaging, and examined macrophage infiltration in the Ang II model using 65 apolipoprotein E deficient mice. Aortic rupture occurred in 16 mice (25 % and was nearly as prevalent at the aortic arch (44 % as it was in the suprarenal region (56 % and was most common within the first seven days after Ang II infusion (12 of 16; 75 %. Longitudinal ultrasound screening was found to correlate nicely with histological analysis and AAA volume renderings showed a significant relationship with AAA severity index. Aortic dissection preceded altered flow patterns and macrophage infiltration was a prominent characteristic of developing AAAs. Targeting the inflammatory component of AAA disease with novel therapeutics will hopefully lead to new strategies to attenuate aneurysm growth and aortic rupture.

  4. Ruptured Abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Jessica Andrusaitis

    2017-07-01

    Full Text Available History of present illness: A 69-year-old male with poorly controlled hypertension presented with 1 hour of severe low back pain that radiated to his abdomen. The patient was tachycardic and had an initial blood pressure of 70/40. He had a rigid and severely tender abdomen. The patient’s history of hypertension, abnormal vital signs, severity and location of his pain were suspicious for a ruptured abdominal aortic aneurysm (AAA. Therefore, a computed tomography angiogram (CTA was ordered. Significant findings: CTA demonstrated a ruptured 7.4 cm infrarenal abdominal aortic aneurysm with a large left retroperitoneal hematoma. Discussion: True abdominal aortic aneurysm is defined as at least a 3cm dilatation of all three layers of the arterial wall of the abdominal aorta.1 An estimated 15,000 people die per year in the US of this condition.2 Risk factors for AAA include males older than 65, tobacco use, and hypertension.1,3,4 There are also congenital, mechanical, traumatic, inflammatory, and infectious causes of AAA.3 Rupture is often the first manifestation of the disease. The classic triad of abdominal pain, pulsatile mass, and hypotension is seen in only 50% of ruptured AAAs.5 Pain (abdominal, groin, or back is the most common symptom. The most common misdiagnoses of ruptured AAAs are renal colic, diverticulitis, and gastrointestinal hemorrhage.6 Bedside ultrasonography is the fastest way to detect this condition and is nearly 100% sensitive.1 One study showed that bedside ultrasounds performed by emergency physicians had a sensitivity of .94 [95% CI = .86-1.0] and specificity of 1 [95% CI = .98-1.0] for detecting AAAs.7 CTA has excellent sensitivity (approximately 100% and yields the added benefit of facilitating surgical planning and management.1 Without surgical treatment, a ruptured AAA is almost uniformly fatal, and 50% of those who undergo surgery do not survive.1 Early resuscitation and coordination with vascular surgery should be

  5. Reoperative Aortic Root Replacement in Patients with Previous Aortic Root or Aortic Valve Procedures

    Directory of Open Access Journals (Sweden)

    Byung Kwon Chong

    2016-08-01

    Full Text Available Background: Generalization of standardized surgical techniques to treat aortic valve (AV and aortic root diseases has benefited large numbers of patients. As a consequence of the proliferation of patients receiving aortic root surgeries, surgeons are more frequently challenged by reoperative aortic root procedures. The aim of this study was to evaluate the outcomes of redo-aortic root replacement (ARR. Methods: We retrospectively reviewed 66 patients (36 male; mean age, 44.5±9.5 years who underwent redo-ARR following AV or aortic root procedures between April 1995 and June 2015. Results: Emergency surgeries comprised 43.9% (n=29. Indications for the redo-ARR were aneurysm (n=12, pseudoaneurysm (n=1, or dissection (n=6 of the residual native aortic sinus in 19 patients (28.8%, native AV dysfunction in 8 patients (12.1%, structural dysfunction of an implanted bioprosthetic AV in 19 patients (28.8%, and infection of previously replaced AV or proximal aortic grafts in 30 patients (45.5%. There were 3 early deaths (4.5%. During follow- up (median, 54.65 months; quartile 1–3, 17.93 to 95.71 months, there were 14 late deaths (21.2%, and 9 valve-related complications including reoperation of the aortic root in 1 patient, infective endocarditis in 3 patients, and hemorrhagic events in 5 patients. Overall survival and event-free survival rates at 5 years were 81.5%±5.1% and 76.4%±5.4%, respectively. Conclusion: Despite technical challenges and a high rate of emergency conditions in patients requiring redo-ARR, early and late outcomes were acceptable in these patients.

  6. Viscoresistive g-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Paris, R.B.

    1980-01-01

    The resistive G-mode and its particular form, the resistive ballooning mode, are treated as limits of a single simple model. MHD theory including parallel and perpendicular viscosity, finite shear, and finite beta is employed to study their linear stability

  7. Treatment of tuberculous bronchostenosis: balloon bronchoplasty

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Im, Jung Gi; Han, Joon Koo; Park, Jae Hyung

    1993-01-01

    The purpose of this study is to evaluate the efficacy of the balloon bronchoplasty in the treatment of the tuberculous bronchostenosis. Balloon bronchoplasty was performed in thirteen patients with stenosis of the left main bronchus (two with combined left upper and lower lobar bronchostenosis) using a inflatable balloon catheter under a fluoroscopic guide. We analysed the changes in the severity of dyspnea and wheezing, serial FEV1/FVC as a parameter of the airflow obstruction, and bronchial diameter and lung volume on chest radiographs. The extent of pulmonary tuberculosis was correlated with the improvement of FEV1/ FVC. There was an improvement of dyspnea in 69% (9/13), decrease of wheezing in 69% (9/13), significant increase of FEV1/FVC in 18% (2/11). The increase of the bronchial diameter and lung volume were seen in 84% (11/13) and 53% (7/13), respectively. The significant increase of FEV1/FVC was seen in 28% (2/7) of the patients with lung involvement of tuberculous less than one third of left upper lobe, whereas there was no increase in those of more than one third. The was no complication except transient leukocytosis, fever and blood-tinged sputum. In conclusion, balloon bronchoplasty is effective in the treatment of medically intractable tuberculous bronchostenosis, and can be considered as an initial method of treatment

  8. Low dose intravaginal misoprostol versus intracervical balloon ...

    African Journals Online (AJOL)

    Background:The efficacy and safety of low dose misoprostol as a ripening agent compared to the widely used balloon catheter in developing countries is undetermined. Objective:To compare the safety and efficacy of a low dose intravaginal misoprostol and intracervical Foley's catheter for cervical ripening. Design:A ...

  9. Double-balloon endoscopy: Who needs it?

    DEFF Research Database (Denmark)

    Hendel, J.W.; Vilmann, P.; Jensen, T.

    2008-01-01

    Objective. Double-balloon endoscopy (DBE) made the small bowel accessible to inspection and therapy in its entirety. However, DBE is a time-consuming procedure that requires a highly skilled endoscopist, several nurses and - more often than not - anesthesiological support. This makes the selection...

  10. Gastrostomy feeding tube - pump - child

    Science.gov (United States)

    ... tube feeding; PEG tube care; Feeding - gastrostomy tube - pump; G-tube - pump; Gastrostomy button - pump; Bard Button - pump; MIC-KEY - pump ... Gather supplies: Feeding pump (electronic or battery powered) Feeding ... pump (includes a feeding bag, drip chamber, roller clamp, ...

  11. Endovascular “Intimal Flap Septostomy” for Safe Landing of a Stent Graft in an Anastomotic Pseudoaneurysm of Chronic Type B Aortic Dissection

    Directory of Open Access Journals (Sweden)

    Yoshiaki Saito

    Full Text Available : Objective/Background: The purpose of this report is to demonstrate a novel endovascular technique for gaining and producing the maximal landing zone for a thoracic stent graft in a patient with a chronic type B aortic dissection. Methods: The patient was a 64 year old man with chronic type B aortic dissection. He had developed acute type B aortic dissection and undergone descending thoracic replacement (Zone 2–Th10 12 years earlier. During follow-up, he developed an anastomotic false aneurysm distally. In the initial operation, the distal anastomosis was performed with fenestration of the dissecting membrane. Computed tomography showed a pseudoaneurysm of 54 mm that was positioned 9 cm proximal to the coeliac artery. The landing zone was < 20 mm in the fenestrated area. At surgery, the true and false lumens were each cannulated from the femoral artery, and a pull through form was made just above the fenestrated flap. After the wire exchange, a 4 mm cutting balloon was positioned on the bottom of the flap, and the flap was gently sawed about 3.5 cm. Results: After stent graft placement no endoleak was observed. The patient was discharged without any complications. Conclusion: This technique was effective in producing a sufficient landing zone for endovascular aortic repair in a patient with an anastomotic pseudoaneurysm of chronic type B aortic dissection. Keywords: TEVAR, Thoracic aortic aneurysm, Chronic type B aortic dissection, Endovascular fenestration

  12. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    Science.gov (United States)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  13. The bicuspid aortic valve and its relation to aortic dilation

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2010-01-01

    Full Text Available BACKGROUND: A bicuspid aortic valve (BAV is a common congenital heart disease, which affects 1-2% of the population. However, the relationship between BAVs and aortic dilation has not been sufficiently elucidated. METHODS: A total of 241 BAV patients who were referred to this hospital for cardiac surgey over a 4.75-year period were included in this study. In addition to the clinical characteristics of the included patients, the morphological features of the aortic valve and aorta, the length of the left main coronary artery, and the laboratory findings (the coagulation and hematological parameters as well as the total cholesterol concentration were determined and compared with those of the tricuspid aortic valve (TAV patients. RESULTS: The BAV patients were younger than the TAV patients for a valve surgery in the last 3 months of the study period. The BAV patients were predominantly male. Most of the BAVs that were surgically treated were stenotic, regurgitant, or combined, and only 19 (7.88% were normally functioning valves. According to echocardiography or operative records, 148 (78.31% were type A, 31 (16.40% were type B, and 10 (5.29% were type C. The left main coronary artery was much shorter in the BAV patients than it was in the TAV patients. There was no significant difference between BAV and TAV patients in the total cholesterol concentrations; whereas differences were noted between patients receiving lipid-lowering therapy and those not receiving lipid-lowering therapy. The dimensions of the aortic root, sinotubular junction, and ascending aorta were beyond normal limits, while they were significantly smaller in the BAV patients than in the TAV patients. They were also much smaller in patients receiving statin therapy than those not receiving statin therapy in both groups. Moreover, the aortic dilation in the BAV group was found to be significantly associated with patient age. CONCLUSIONS: The BAV patients developed aortic wall and

  14. Surgical on-pump beating-heart treatment of ischemic patients with low LF ejection fraction: immediate results

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2015-10-01

    Full Text Available Objectives. The study compares the early results of on-pump beating-heart (ONBEAT surgery versus conventional coronary artery bypass grafting (CABG with cardioplegic arrest (ONSTOP in patients with coronary artery disease and left ventricular dysfunction. Methods. In a single-center randomized trial, 60 patients operated for severe left ventricular dysfunction (EF<35% between January 2012 and January 2014 were randomized to ONBEAT (n=30 or ONSTOP (n=30 cohorts. All patients received preventive hemodynamic support before surgery (determined by randomization: intra-aortic balloon pump or levosimendan. Preoperative, operative and postoperative variables were evaluated in both groups. Results. Preoperative characteristics were similar between both groups. The time of stay in the ICU was 3 (2; 5 days in the first group and 3 (2; 4 days in the second one (p = 0.2. In the ONBEAT group 62 distal anastomoses (30 arterial were performed and in the ONSTOP group 70 distal anastomoses (30 arterial were done (p = 0.3. Completeness of revascularization on the beating heart corresponded to that in the group with cardioplegic arrest. The presence of complications such as stroke (p = 1.0, renal failure (p = 0.5, respiratory events (p = 0.2 and heart failure (p = 0.5 did not differ significantly between the two groups. Atrial fibrillation tended to occur more often in the postoperative period in the ONSTOP group (p = 0.03. The concentration of troponin I at all stages of the study did not differ significantly between the two groups. Both groups showed a significant increase in LV ejection fraction postoperatively: the first group 30 (26; 33 to 34 (30; 39 %, (p = 0,009; the second group - 31 (27 and 33 to 35 (30; 37 % (p = 0.01. Hospital mortality in the first group was observed in 1 case and in the second one in two cases (p = 0.5. Conclusions. The on-pump beating heart technique has no advantages comparing with conventional CABG in cases of preventive hemodynamic

  15. Cellular Mechanisms of Aortic Valve Calcification.

    Science.gov (United States)

    Zhiduleva, E V; Irtyuga, O B; Shishkova, A A; Ignat'eva, E V; Kostina, A S; Levchuk, K A; Golovkin, A S; Rylov, A Yu; Kostareva, A A; Moiseeva, O M; Malashicheva, A B; Gordeev, M L

    2018-01-01

    Comparative in vitro study examined the osteogenic potential of interstitial cells of aortic valve obtained from the patients with aortic stenosis and from control recipients of orthotopic heart transplantation with intact aortic valve. The osteogenic inductors augmented mineralization of aortic valve interstitial cells (AVIC) in patients with aortic stenosis in comparison with the control level. Native AVIC culture of aortic stenosis patients demonstrated overexpression of osteopontin gene (OPN) and underexpression of osteoprotegerin gene (OPG) in comparison with control levels. In both groups, AVIC differentiation was associated with overexpression of RUNX2 and SPRY1 genes. In AVIC of aortic stenosis patients, expression of BMP2 gene was significantly greater than the control level. The study revealed an enhanced sensitivity of AVIC to osteogenic inductors in aortic stenosis patients, which indicates probable implication of OPN, OPG, and BMP2 genes in pathogenesis of aortic valve calcification.

  16. Imaging techniques in transcatheter aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Quaife RA

    2013-11-01

    Full Text Available Robert A Quaife, Jennifer Dorosz, John C Messenger, Ernesto E Salcedo Division of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Calcific aortic stenosis is now understood as a complex valvular degenerative process sharing many risk factors with atherosclerosis. Once patients develop symptomatic calcific aortic stenosis, the only effective treatment is aortic valve replacement. In the past decade, transcatheter aortic valve replacement (TAVR has been developed as an alternative to surgery to treat severe calcific aortic stenosis. Cardiac imaging plays a pivotal role in the contemporary management of patients with calcific aortic stenosis, and particularly in patients being considered for TAVR, who demand detailed imaging of the aortic valve apparatus. In this review, we highlight the role of cardiac imaging for patient selection, procedural guidance, and evaluation of results of TAVR. Keywords: aortic stenosis, cardiovascular imaging, transcutaneous aortic valve replacement

  17. Adult thoracic and abdominal aortic

    Directory of Open Access Journals (Sweden)

    Randa O. Kaddah

    2016-06-01

    Conclusion: Aortic COA could be found in any segment of the aorta. Proper identification of the anatomical details and pressure gradient studies are important factors affecting the plan of management.

  18. Implantation of transcatheter aortic valve prosthesis through the ascending aorta concomitant with coronary artery bypass grafting without cardiopulmonary bypass

    Science.gov (United States)

    Leal, João Carlos Ferreira; Avanci, Luis Ernesto; Abelaira Filho, Achilles; Almeida, Thiago Faria; Braile, Domingo Marcolino

    2014-01-01

    Introdution The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. Objective The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Methods Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. Results There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Conclusion Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients. PMID:25714221

  19. Unoperated aortic aneurysm

    DEFF Research Database (Denmark)

    Perko, M J; Nørgaard, M; Herzog, T M

    1995-01-01

    From 1984 to 1993, 1,053 patients were admitted with aortic aneurysm (AA) and 170 (15%) were not operated on. The most frequent reason for nonoperative management was presumed technical inoperability. Survivals for patients with thoracic, thoracoabdominal, and abdominal AA were comparable....... No significant differences in survival for patients with dissecting and nondissecting AA were detected. In all, 132 patients (78%) died and 78 (59%) of them died of rupture. Mean time to rupture was 1,300 +/- 8 days. Cumulative 5-year hazard of rupture for the dissecting AA was twice that of the nondissecting (p...... A dissections. The results suggest that type B dissections may have a more favorable course if operated on, but a prospective, randomized study is necessary to confirm this observation. We believe that older patients and those with a small aneurysm may benefit from early, elective operation....

  20. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  1. Endovascular Treatment of Infrarenal Abdominal Aortic Lesions With or Without Common Iliac Artery Involvement

    International Nuclear Information System (INIS)

    Önder, Hakan; Oğuzkurt, Levent; Gür, Serkan; Tekbaş, Güven; Gürel, Kamil; Coşkun, İsa; Özkan, Uğur

    2013-01-01

    To evaluate the results of stent placement for obstructive atherosclerotic aortic disease with or without involvement of the common iliac artery. Forty patients had self-expanding stents primarily or after balloon dilatation in the abdominal aorta between January 2005 and May 2011. All patients had trouble walking. Follow-up examinations were performed with clinical visits; these included color Doppler ultrasonography and computed tomographic angiography. Technical, clinical, and hemodynamic success was achieved in all patients. None of the patients underwent reintervention during the follow-up period, which ranged from 3 months to 6 years (median 24 months). Nine complications occurred in six patients. Of the nine complications, four were distal thromboembolisms, which were successfully treated with catheter-directed thrombolysis or anticoagulation therapy. Endovascular treatment of the obstructive aortic disease using self-expanding stents was safe and effective, with high technical success and long-term patency. Thromboembolic complications were high even though direct stenting was considered protective for thromboembolism formation. Particularly for infrarenal aortic stenosis, it can be recommended as the first-line treatment option for patients with obstructive atherosclerotic aortic disease.

  2. Extra-Anatomical Bypass: A Surgical Option for Recurrent Aortic Coarctation

    Directory of Open Access Journals (Sweden)

    Alban Malaj

    2013-01-01

    Full Text Available Background. Balloon aortoplasty with or without stenting is a less invasive alternative to open surgery for the management of recurrent isthmic coarctation. However, in patients with previous small size tube graft, an open surgical correction is mandatory and, in most cases, an anatomical aortic reconstruction is carried out. Methods. We present the case of a 48-year-old woman with recurrent aortic coarctation and systemic hypertension with systolic value around 190–200 mmHg and preoperative systolic pressure gradient 70 mmHg, submitted to an extra-anatomical bypass. Through a median sternotomy, an extra-anatomical bypass from ascending to descending aorta was performed. Results. No intra- or postoperative complications were observed. The postoperative pressure gradient was 10 mmHg and the systolic pressure ranged from 130 to 140 mmHg. Conclusion. The extra-anatomical bypass can be considered an effective and safe alternative to the anatomical aortic reconstruction in the cases with recurrent aortic coarctation unfit for endovascular treatment.

  3. Endovascular Treatment of Infrarenal Abdominal Aortic Lesions With or Without Common Iliac Artery Involvement

    Energy Technology Data Exchange (ETDEWEB)

    Oender, Hakan, E-mail: drhakanonder@hotmail.com [Dicle University Medical Faculty, Department of Radiology (Turkey); Oguzkurt, Levent [Baskent University Medical Faculty, Department of Radiology (Turkey); Guer, Serkan [Sifa University Medical Faculty, Department of Radiology (Turkey); Tekbas, Gueven [Dicle University Medical Faculty, Department of Radiology (Turkey); Guerel, Kamil [Abant Izzet Baysal University Medical Faculty, Department of Radiology (Turkey); Coskun, Isa [Baskent University Medical Faculty, Department of Cardiovascular Surgery (Turkey); Oezkan, Ugur [Baskent University Medical Faculty, Department of Radiology (Turkey)

    2013-02-15

    To evaluate the results of stent placement for obstructive atherosclerotic aortic disease with or without involvement of the common iliac artery. Forty patients had self-expanding stents primarily or after balloon dilatation in the abdominal aorta between January 2005 and May 2011. All patients had trouble walking. Follow-up examinations were performed with clinical visits; these included color Doppler ultrasonography and computed tomographic angiography. Technical, clinical, and hemodynamic success was achieved in all patients. None of the patients underwent reintervention during the follow-up period, which ranged from 3 months to 6 years (median 24 months). Nine complications occurred in six patients. Of the nine complications, four were distal thromboembolisms, which were successfully treated with catheter-directed thrombolysis or anticoagulation therapy. Endovascular treatment of the obstructive aortic disease using self-expanding stents was safe and effective, with high technical success and long-term patency. Thromboembolic complications were high even though direct stenting was considered protective for thromboembolism formation. Particularly for infrarenal aortic stenosis, it can be recommended as the first-line treatment option for patients with obstructive atherosclerotic aortic disease.

  4. A system for visualization and automatic placement of the endoclamp balloon catheter

    Science.gov (United States)

    Furtado, Hugo; Stüdeli, Thomas; Sette, Mauro; Samset, Eigil; Gersak, Borut

    2010-02-01

    The European research network "Augmented Reality in Surgery" (ARIS*ER) developed a system that supports minimally invasive cardiac surgery based on augmented reality (AR) technology. The system supports the surgical team during aortic endoclamping where a balloon catheter has to be positioned and kept in place within the aorta. The presented system addresses the two biggest difficulties of the task: lack of visualization and difficulty in maneuvering the catheter. The system was developed using a user centered design methodology with medical doctors, engineers and human factor specialists equally involved in all the development steps. The system was implemented using the AR framework "Studierstube" developed at TU Graz and can be used to visualize in real-time the position of the balloon catheter inside the aorta. The spatial position of the catheter is measured by a magnetic tracking system and superimposed on a 3D model of the patient's thorax. The alignment is made with a rigid registration algorithm. Together with a user defined target, the spatial position data drives an actuator which adjusts the position of the catheter in the initial placement and corrects migrations during the surgery. Two user studies with a silicon phantom show promising results regarding usefulness of the system: the users perform the placement tasks faster and more accurately than with the current restricted visual support. Animal studies also provided a first indication that the system brings additional value in the real clinical setting. This work represents a major step towards safer and simpler minimally invasive cardiac surgery.

  5. Results of aortic root reimplantation in patients with ascending aortic aneurysm and concomitant aortic insufficiency

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-01-01

    Full Text Available Objective. The research was designed to evaluate the results of valve-sparing operations: aortic root reimplantation versus aortic valve reimplantation when repairing an ascending aortic aneurysm with concomitant aortic insufficiency.Methods. Within a blind prospective randomized study conducted over a period from 2011 to 2015, 64 patients underwent aortic valve-sparing surgery. The inclusion criteria were the presence of an aortic aneurysm of the ascending aorta exceeding 4.5 cm and concomitant aortic insufficiency. All patients were divided into two groups: FS-group, aortic root reimplantation (modified Florida Sleeve technique (n = 32 and D-group, aortic valve reimplantation (David procedure (n = 32. The average age of patients was 57±13 (23–73 years in the FS-group and 55±11 (15–72 years in the D-group (p = 0.54. Both groups had 78% of males (p>0.99. A Marfan syndrome was identified in 6% and 9% in the FS-group and D-group respectively (p>0.99. Mean diameter of the sinuses of Valsalva was 51±7 mm and 56±10 mm (p = 0.09, aortic insufficiency 2.6±0.7 and 2.8±0.8 (p = 0.15 in the FS-group and D-group respectively. In the FS-group and D-group LVEDD amounted to 5.5±0.7 mm and 5.9±1.0 mm (p = 0.09 respectively. All patients took echocardiography in the preoperative, postoperative and follow-up periods.Results. In the long-term period, the degree of aortic regurgitation was 1.2±0.1 in the FS-group and 1.3±0.6 in the D-group (p = 0.72. LVEDD was 123±23 mm in the FS-group and 139.6±80 mm in the D-group at follow-up (p = 0.77. There were no statistically significant differences in the analysis of complications. Overall 30-day in-hospital mortality was 7.8%. There were 2 (6.3% deaths in the FS-group and 3 (9.4% in the D-group (p = 0.5.Late mortality was 6.3% in the FS-group and 3.1% in the D-group (p>0.99. Cumulative survival at 4 years was 84.3% and 84.8% in the FS-group and the D-group respectively (p = 0.94. Cumulative freedom from

  6. Cost-Effectiveness of Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis Versus Surgical Aortic Valve Replacement

    Science.gov (United States)

    Reynolds, Matthew R.; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A.; Magnuson, Elizabeth A.; Galper, Benjamin Z.; Meduri, Christopher U.; Arnold, Suzanne V.; Baron, Suzanne J.; Reardon, Michael J.; Adams, David H.; Popma, Jeffrey J.; Cohen, David J.

    2016-01-01

    Background Prior studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. Objectives The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. Methods We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk pivotal trial. Empirical data regarding survival and quality of life (QOL) over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. perspective. Results Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month QOL. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years (QALYs; 0.41 life-years [LYs]) with 3% discounting. Lifetime incremental cost-effectiveness ratios (ICERs) were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ~$1,650 would lead to an ICER prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. standards. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. PMID:26764063

  7. Transcatheter aortic valve implantation for bicuspid aortic valve stenosis: Acute and intermediate-term outcomes in a high volume institution

    Directory of Open Access Journals (Sweden)

    Anže Djordjević

    2017-03-01

    Full Text Available Background: We report our experience with transcatheter aortic valve implantation (TAVI in patients with bicuspid aortic valve (BAV stenosis.Methods: Perioperative and intermediate-term follow-up data were retrospectively analysed. All procedures were performed within the premises of an experienced high-volume TAVI centre.Results: Tirty-three consecutive BAV patients (age 55 to 87 years underwent TAVI. Mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE was 23,2 ± 19,3. Transapical Edwards Sapien® valve was implanted in the majority of patients (87.9 %. Nine patients (27.3 % required post-ballooning of the implanted valve for moderate to severe paravalvular leak, 3 patients (9 % required a second valve implantation for persistent severe paravalvular leak, and 2 (6 % required conversion to conventional surgery. Post-operative mild aortic regurgitation (AR was presented in 12 patients (36.4% and AR = 2 in 3 %. No AR > 2 was observed. Te device success rate according to the valve academic research consortium (VARC criteria was 82 %. Similar BAV anatomy, calcium distribution, type and size of implanted valve were noticed in patients with and without residual AR. Tere was no thirty-day mortality. Two-year estimated survival was 70 % (CI: 52.7–93.1 and was similar in patients with and without post-procedural residual paravalvular leak.Conclusions: TAVI in BAV stenosis is feasible but, even in experienced centres, is technically more challenging and is associated with a higher rate of post-dilatation, re-valving, and conversion to conventional surgery. Results should be re-tested in light of the recent introduction of second-generation TAVI prostheses.

  8. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  9. Insulin pump (image)

    Science.gov (United States)

    The catheter at the end of the insulin pump is inserted through a needle into the abdominal ... with diabetes. Dosage instructions are entered into the pump's small computer and the appropriate amount of insulin ...

  10. Proton pump inhibitors

    Science.gov (United States)

    Proton pump inhibitors (PPIs) are medicines that work by reducing the amount of stomach acid made by ... Proton pump inhibitors are used to: Relieve symptoms of acid reflux, or gastroesophageal reflux disease (GERD). This ...

  11. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  12. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    Science.gov (United States)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  13. Vertical pump assembly

    International Nuclear Information System (INIS)

    Dohnal, M.; Rosel, J.; Skarka, V.

    1988-01-01

    The mounting is described of the drive assembly of a vertical pump for nuclear power plants in areas with seismic risk. The assembly is attached to the building floor using flexible and damping elements. The design allows producing seismically resistant pumps without major design changes in the existing types of vertical pumps. (E.S.). 1 fig

  14. An Engineering Analysis of the Aortic Valve Dynamics in Patients with Rotary Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    George Faragallah

    2013-01-01

    Full Text Available The use of a rotary Left Ventricular Assist Device (LVAD as a bridge-to-recovery treatment is gaining considerable attention in the LVAD research community. Using a mathematical model of the cardiovascular-LVAD system, this paper intends to define the critical control parameters in terms of power and rotational speed of the LVAD to ensure normal dynamics of the aortic valve for different levels of patient's activity and severity of heart failure. The effects of permanent closure of the aortic valve on the hemodynamics of the patient and the pump flow characteristics, if the critical control values are exceeded, are also examined. Additionally, LVAD power and speed control parameters that yield a given percentage of the cardiac cycle during which the aortic valve remains open are examined indicating that the severity of the heart failure is a very important factor in deciding the appropriateness of the LVAD as a bridge-to recovery treatment.

  15. Aortic Wall Injury Related to Endovascular Therapy for Aortic Coarctation.

    Science.gov (United States)

    Tretter, Justin T; Jones, Thomas K; McElhinney, Doff B

    2015-09-01

    Aortic wall complications can occur in unrepaired aortic coarctation (CoA) and after surgical repair or endovascular treatment. This review summarizes the available literature and current understanding of aortic wall injury (AWI) surrounding the management of CoA, focusing specifically on acute and follow-up AWI after endovascular treatment. There have been 23 reported cases of aortic rupture after endovascular treatment for CoA, including angioplasty alone, bare metal stenting, and primary covered stent therapy. Even if these published cases represent only a minority of ruptures that have actually occurred, the incidence is substantially treatment of CoA seems to be declining in frequency with increasing experience and improving technology, it remains one of the most important potential adverse outcomes. Long-term surveillance for new AWI and monitoring of existing AWI is mandatory, with institution of appropriate treatment when necessary. A central research focus in this population should be determination of the appropriate treatment for both native and recurrent CoA across various ages with regard to limiting recurrent CoA and preventing associated aortic wall complications, in addition to determining the appropriate treatment of various AWI. Consistent definitions and reporting are necessary to truly understand the incidence of, risk factors for, and measures protective against AWI after angioplasty or stent implantation for CoA. © 2015 American Heart Association, Inc.

  16. Evolution of scientific ballooning and its impact on astrophysics research

    Science.gov (United States)

    Jones, William Vernon

    2014-05-01

    As we celebrate the centennial year of the discovery of cosmic rays on a manned balloon, it seems appropriate to reflect on the evolution of ballooning and its scientific impact. Balloons have been used for scientific research since they were invented in France more than 200 years ago. Ballooning was revolutionized in 1950 with the introduction of the so-called natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for more than a half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing the next generation super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. The Astro2010 Decadal Survey report supports super-pressure balloon development and the giant step forward it offers with ultra-long-duration balloon (ULDB) flights at constant altitudes for about 100 days.

  17. Off-Pump Coronary Artery Bypass Grafting and Stroke-Exploratory Analysis of the GOPCABE Trial and Methodological Considerations.

    Science.gov (United States)

    Reents, Wilko; Zacher, Michael; Boergermann, Jochen; Kappert, Utz; Hilker, Michael; Färber, Gloria; Albert, Marc; Holzhey, David; Conradi, Lenard; Riess, Friedrich Christian; Veeckman, Philippe; Strauch, Justus T; Diegeler, Anno; Böning, Andreas

    2018-03-22

     Coronary artery bypass grafting (CABG) without cardiopulmonary bypass (off-pump CABG) may reduce severe adverse events including stroke.  In the German Off-Pump Coronary Artery Bypass Grafting in Elderly patients trial, the rate of major adverse cardiovascular events was compared in 2,394 elderly (≥ 75 years) patients undergoing CABG with (on-pump) or without (off-pump) cardiopulmonary bypass. This exploratory post-hoc analysis investigated the impact of surgical aortic manipulation on the rate of stroke.  There was no significant difference in the rate of stroke within 30 days after surgery between both groups (off-pump: 2.2%; on-pump: 2.7%; odds ratio [OR]: 0.83 [0.5-1.38]; p  = 0.47). Within the off-pump group, different degrees of aortic manipulation did not lead to significant different stroke rates (tangential clamping: 2.3%; OR 0.86 [0.46-1.60]; clampless device: 1.8%; OR 0.67 [0.26-1.75]; no aortic manipulation: 2.4%; OR 0.88 [0.37-2.14]). An aggregate analysis including more than 10,000 patients out of the four recent major trials also yielded comparable stroke rates for on- and off-pump CABG (off-pump: 1.4%; on-pump: 1.7%; OR 0.87 [0.64-1.20]).  Within recent prospective randomized multicenter trials off-pump CABG did not result in lower stroke rates. The possible intrinsic benefit of off-pump CABG may be offset by the complexity of the operative therapy as well as the multiple pathomechanisms involved in perioperative stroke. Georg Thieme Verlag KG Stuttgart · New York.

  18. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p

  19. Aortic compliance in patients with aortic regurgitation. Evaluation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murai, Sachiko; Hamada, Seiki; Ueguchi, Takashi

    2005-01-01

    The purpose of this study was to assess by means of cine magnetic resonance imaging (MRI) aortic compliance before and after aortic valve replacement (AVR with SJM (St. Jude Medical, St paul, MN) valve) in patients with aortic regurgitation (AR). Two groups (healthy controls and patients with severe isolated AR) of 10 subjects each were included in this study. Cine MRI was performed at three locations of the aorta, and aortic compliance was calculated by dividing the maximum change in the aortic area by pulse pressure. Cine MRI is useful to assess abnormalities of aortic compliance in patients with AR. Compared with the control group, aortic compliance in the AR group was significantly less in the ascending aorta (p<0.05), decreasing in order of aortic location. After AVR, aortic compliance improved for all locations. Cine MRI enables assessment of aortic biophysical properties such as a compliance for evaluating the progression of AR and the efficacy of treatment. (author)

  20. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1981-01-01

    A liquid metal pump comprising a shaft support structure which is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft carries an impeller and the support structure carries an impeller cage which is slidably disposed in a diffuser so as to allow complete removal of pump internals for inspection and repair. The diffuser is concentrically supported in the pump housing which also takes up all reaction forces generated by the discharge of the liquid metal from the diffuser, with floating seals arranged between impeller cage and the diffuser. The space between the diffuser and the pump housing permits the incoming liquid to essentially surround the diffuser. (author)

  1. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  2. Retrograde prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Hulbert, J.; Letourneau, J.G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1987-01-01

    The authors performed retrograde prostatic urethroplasty in 18 patients using a 25-mm urethroplasty balloon catheter. The procedure was performed on an outpatient basis under local anesthesia. Voiding cystourethrography, retrograde urethrography, rectal US, and MRE imaging were performed before and immediately after the procedure and at 2 weeks and 3, 6, 12, and 18 months. Long-term results at 18 months and possible clinical implications are discussed

  3. A History of Thoracic Aortic Surgery.

    Science.gov (United States)

    McFadden, Paul Michael; Wiggins, Luke M; Boys, Joshua A

    2017-08-01

    Ancient historical texts describe the presence of aortic pathology conditions, although the surgical treatment of thoracic aortic disease remained insurmountable until the 19th century. Surgical treatment of thoracic aortic disease then progressed along with advances in surgical technique, conduit production, cardiopulmonary bypass, and endovascular technology. Despite radical advances in aortic surgery, principles established by surgical pioneers of the 19th century hold firm to this day. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Abdominal aortic feminism.

    Science.gov (United States)

    Mortimer, Alice Emily

    2014-11-14

    A 79-year-old woman presented to a private medical practice 2 years previously for an elective ultrasound screening scan. This imaging provided the evidence for a diagnosis of an abdominal aortic aneurysm (AAA) to be made. Despite having a number of recognised risk factors for an AAA, her general practitioner at the time did not follow the guidance set out by the private medical professional, that is, to refer the patient to a vascular specialist to be entered into a surveillance programme and surgically evaluated. The patient became symptomatic with her AAA, was admitted to hospital and found to have a tender, symptomatic, 6 cm leaking AAA. She consented for an emergency open AAA repair within a few hours of being admitted to hospital, despite the 50% perioperative mortality risk. The patient spent 4 days in intensive care where she recovered well. She was discharged after a 12 day hospital stay but unfortunately passed away shortly after her discharge from a previously undiagnosed gastric cancer. 2014 BMJ Publishing Group Ltd.

  5. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  6. Long Duration Balloon Charge Controller Stack Integration

    Science.gov (United States)

    Clifford, Kyle

    NASA and the Columbia Scientific Balloon Facility are interested in updating the design of the charge controller on their long duration balloon (LDB) in order to enable the charge controllers to be directly interfaced via RS232 serial communication by a ground testing computers and the balloon's flight computer without the need to have an external electronics stack. The design involves creating a board that will interface with the existing boards in the charge controller in order to receive telemetry from and send commands to those boards, and interface with a computer through serial communication. The inputs to the board are digital status inputs indicating things like whether the photovoltaic panels are connected or disconnected; and analog inputs with information such as the battery voltage and temperature. The outputs of the board are 100ms duration command pulses that will switch relays that do things like connect the photovoltaic panels. The main component of this design is a PIC microcontroller which translates the outputs of the existing charge controller into serial data when interrogated by a ground testing or flight computer. Other components involved in the design are an AD7888 12-bit analog to digital converter, a MAX3232 serial transceiver, various other ICs, capacitors, resistors, and connectors.

  7. Intragastric balloon for treatment-resistant obesity: safety, tolerance, and efficacy of 1-year balloon treatment followed by a 1-year balloon-free follow-up

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth M. H.; Tytgat, Guido N. J.

    2005-01-01

    Background: Prior efforts to treat obesity with intragastric balloons were thwarted by high complication rates. Therefore, fundamental requirements for optimal balloon designs were defined. The aim of the present study was to investigate the effectiveness, the safety; and the tolerance of a new

  8. Aortic root replacement with a pulmonary autograft

    NARCIS (Netherlands)

    R.B. Hokken (Raymond)

    1997-01-01

    textabstractAortic valve disease in the pediatric age group is usually a consequence of congenital aortic stenosis, which may be isolated or may be a part of an anomaly of the left ventricular outflow tract or the aortic root. Management of these patients is difficult. Neonates and infants

  9. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-12-31

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  10. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-01-01

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  11. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  12. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won

    2005-01-01

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  13. Chylothorax complicating thoracic aortic surgery.

    Science.gov (United States)

    Kanakis, Meletios A; Misthos, Panagiotis; Kokotsakis, John N; Lioulias, Achilleas G

    2011-07-01

    Chylothorax is a very rare complication of patients undergoing thoracic aortic aneurysm repair. Possible mechanisms of this condition during thoracic aorta operations and current therapeutic strategies are analyzed according to our experience and thorough search of the English literature. Current experience with chylothorax occurring during thoracic aortic surgery is analyzed in this review by collecting data retrieved from English literature research. Significant risk factors for postoperative chylothorax development after thoracic aorta surgical procedures are thoracic aortic reoperations and descending thoracic repairs. Various treatment modalities from conservative to operative intervention have been proposed. Currently, the morbidity and mortality have improved due to prompt management. Surgical intervention is needed when response to conservative treatment has failed.  © 2011 Wiley Periodicals, Inc.

  14. Superpressure Balloon Design Using Nonlinear Viscoelasticity

    Science.gov (United States)

    Rand, James; Rand, James; Wakefield, David

    Stratospheric balloon platforms are used extensively by scientists for a variety of purposes. The typical balloon used today is the zero pressure natural shape fabricated from a thin film of linear low density polyethylene. This material has been found to possess a variety of desirable characteristics suitable to this environment. This film will remain ductile at very low temperatures which will permit it to develop large strains if necessary to satisfy equilibrium considerations. However, in order to achieve long duration flight without significant changes in altitude, the balloon should be pressurized to the extent necessary to maintain constant volume during typical variations in temperature. In the past, pressurized balloons were fabricated from other materials in order to achieve significant increases in strength. Thin films of polyester or polyimide have been used to make relatively small spheres capable of long duration flight. Unfortunately, these materials do not have the ductility of polyethylene at low temperature and are somewhat more fragile and subject to damage. In recent years various organizations have attempted to use the characteristic shape of a pumpkin to limit the stresses in a balloon envelope to that which can be accommodated by laminated fabric materials. While developing the design, analysis and construction techniques for this type of system, the use of polyethylene has been successfully demonstrated to provide a reliable envelope. This shape is achieved by using high strength members in the meridional direction to carry the very high loads generated by the pressure. These so called "tendons" have very low elongation and serve to limit the deformation of the film in that direction. However, earlier designs attempted to limit the stresses in the circumferential direction by using a lobe angle to control the stress. Unfortunately this has led to a number of stability problems with this type of balloon. In order to control the stability of

  15. [Balloon cell nevi of the conjunctiva (author's transl)].

    Science.gov (United States)

    Schlageter, P E; Daicker, B

    1975-06-01

    The clinical and histological features of three cases of conjunctival balloon cell nevi are described. This peculiar form of nevus is very rare in the conjunctiva. The findings are compared with the descriptions in the literature of dermal balloon cell nevi. They demonstrate, that the conjunctival and dermal tumours are of idential histological structure. The proliferations of the conjunctival epithelium often found in conjunctival nevi do not modify the balloon cell nevi. These can not be diagnosed clinically. The problems of the pathogenesis of the balloon cell nevi are discussed.

  16. Advanced Li batteries for terrestrial balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — For future advanced terrestrial balloon missions, NASA requires energy dense and power dense energy storage solutions significantly exceeding the performance of...

  17. Hyperspectral Polarimeter for Monitoring Balloon Strain, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously unattainable...

  18. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  19. An Overview of Current and Future Stratospheric Balloon Mission Capabilities

    Science.gov (United States)

    Smith, Michael

    The modern stratospheric balloon has been used for a variety of missions since the late 1940's. Capabilities of these vehicles to carry larger payloads, fly to higher altitudes, and fly for longer periods of time have increased dramatically over this time. In addition to these basic performance metrics, reliability statistics for balloons have reached unprecedented levels in recent years. Balloon technology developed in the United States in the last decade has the potential to open a new era in economical space science using balloons. As always, the advantage of the balloon platform is the fact that missions can be carried out at a fraction of the cost and schedule of orbital missions. A secondary advantage is the fact that instruments can be re-flown numerous times while upgrading sensor and data processing technologies from year to year. New mission capabilities now have the potential for enabling ground breaking observations using balloons as the primary platform as opposed to a stepping stone to eventual orbital observatories. The limit of very high altitude balloon missions will be explored with respect to the current state of the art of balloon materials and fabrication. The same technological enablers will also be applied to possibilities for long duration missions at mid latitudes with payloads of several tons. The balloon types and their corresponding mission profiles will be presented in a performance matrix that will be useful for potential scientific users in planning future research programs.

  20. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  1. MMP-2 Isoforms in Aortic Tissue and Serum of Patients with Ascending Aortic Aneurysms and Aortic Root Aneurysms

    Science.gov (United States)

    Tscheuschler, Anke; Meffert, Philipp; Beyersdorf, Friedhelm; Heilmann, Claudia; Kocher, Nadja; Uffelmann, Xenia; Discher, Philipp; Siepe, Matthias; Kari, Fabian A.

    2016-01-01

    Objective The need for biological markers of aortic wall stress and risk of rupture or dissection of ascending aortic aneurysms is obvious. To date, wall stress cannot be related to a certain biological marker. We analyzed aortic tissue and serum for the presence of different MMP-2 isoforms to find a connection between serum and tissue MMP-2 and to evaluate the potential of different MMP-2 isoforms as markers of high wall stress. Methods Serum and aortic tissue from n = 24 patients and serum from n = 19 healthy controls was analyzed by ELISA and gelatin zymography. 24 patients had ascending aortic aneurysms, 10 of them also had aortic root aneurysms. Three patients had normally functioning valves, 12 had regurgitation alone, eight had regurgitation and stenosis and one had only stenosis. Patients had bicuspid and tricuspid aortic valves (9/15). Serum samples were taken preoperatively, and the aortic wall specimen collected during surgical aortic repair. Results Pro-MMP-2 was identified in all serum and tissue samples. Pro-MMP-2 was detected in all tissue and serum samples from patients with ascending aortic/aortic root aneurysms, irrespective of valve morphology or other clinical parameters and in serum from healthy controls. We also identified active MMP-2 in all tissue samples from patients with ascending aortic/aortic root aneurysms. None of the analyzed serum samples revealed signals relatable to active MMP-2. No correlation between aortic tissue total MMP-2 or tissue pro-MMP-2 or tissue active MMP-2 and serum MMP-2 was found and tissue MMP-2/pro-MMP-2/active MMP-2 did not correlate with aortic diameter. This evidence shows that pro-MMP-2 is the predominant MMP-2 species in serum of patients and healthy individuals and in aneurysmatic aortic tissue, irrespective of aortic valve configuration. Active MMP-2 species are either not released into systemic circulation or not detectable in serum. There is no reliable connection between aortic tissue—and serum MMP-2

  2. AUTOPERFUSION BALLOON CATHETER FOR COMPLICATED CORONARY ANGIOPLASTY - A PROSPECTIVE-STUDY WITH RETROSPECTIVE CONTROLS

    NARCIS (Netherlands)

    DEMUINCK, ED; VANDIJK, RB; DENHEIJER, P; MEEDER, JG; LIE, KI

    1992-01-01

    Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with

  3. Transcatheter Aortic Valve Replacement for Perceval Sutureless Aortic Valve Failure.

    Science.gov (United States)

    Kalra, Ankur; Reyes, Manuel; Yang, Eric Y; Little, Stephen H; Nabi, Faisal; Barker, Colin M; Ramchandani, Mahesh; Reul, Ross M; Reardon, Michael J; Kleiman, Neal S

    2017-06-01

    As experience with Perceval aortic prosthesis and valve-in-valve TAVR grows, it will be crucial to meticulously document short- and long-term follow-up for establishment of real-world safety and durability of these new technologies.

  4. Wellpoint pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Gilfillan, W.C.

    1990-04-03

    This patent describes a wellpoint pumping system. It comprises: a frame, a positive displacement rotary pump capable of pumping air, water or a mixture thereof mounted upon the frame, the pump having two rotors with intermeshing lobes mounted for counter rotation upon substantially horizontal and parallel shafts. The pump having an inlet port located blow the rotors opening downwardly and an outlet port located above the rotors opening upwardly, a motor for driving the rotors mounted upon the frame, means for coupling the motor to at least one of the rotor shafts to drive at least one of the rotor shafts, means forming a closed air-tight inlet reservoir in the frame below the pump, an outlet reservoir mounted on the frame at a level above the inlet reservoir, an outlet reservoir mounted on the frame at a level above the inlet reservoir, an exhaust conduit for the outlet reservoir, conduit means; water recirculation means; and an adjustable recirculation control valve.

  5. Electrokinetic pumps and actuators

    International Nuclear Information System (INIS)

    Phillip M. Paul

    2000-01-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps

  6. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  7. Quantitative angiographic comparison of elastic recoil after coronary excimer laser-assisted balloon angioplasty and balloon angioplasty alone.

    Science.gov (United States)

    Strikwerda, S; van Swijndregt, E M; Melkert, R; Serruys, P W

    1995-02-01

    Coronary lumen changes during and after excimer laser-assisted balloon angioplasty were measured by quantitative coronary angiography, and the results were compared with the effects of balloon angioplasty alone. Reduction of atherosclerotic tissue mass by laser ablation in the treatment of coronary artery disease may be more effective in enlarging the lumen than balloon angioplasty alone. A series of 57 consecutive coronary lesions successfully treated by xenon chloride excimer laser-assisted balloon angioplasty were individually matched with 57 coronary artery lesions successfully treated by balloon angioplasty alone. The following variables were measured by quantitative coronary analysis: 1) ablation by laser, 2) stretch by balloon dilation, 3) elastic recoil, and 4) acute gain. Matching by stenosis location, reference diameter and minimal lumen diameter resulted in two comparable groups of 57 lesions with identical baseline stenosis characteristics. Minimal lumen diameter before excimer laser-assisted balloon angioplasty and balloon angioplasty alone were (mean +/- SD) 0.73 +/- 0.44 and 0.74 +/- 0.43 mm, respectively. Laser ablation significantly improved minimal lumen diameter by 0.56 +/- 0.44 mm before adjunctive balloon dilation. In both treatment groups, similar-sized balloon catheters (2.59 +/- 0.35 and 2.56 +/- 0.40 mm, respectively) were used. After laser-assisted balloon angioplasty, elastic recoil was 0.84 +/- 0.30 mm (32% of balloon size), which was identical to that after balloon angioplasty alone, namely, 0.82 +/- 0.32 mm (32%). Consequently, both interventions resulted in similar acute gains of 1.02 +/- 0.52 and 1.00 +/- 0.56 mm, respectively. Minimal lumen diameter after intervention was equal in both groups: 1.75 +/- 0.35 and 1.75 +/- 0.34 mm, respectively. The statistical power of this study in which a 25% difference in elastic recoil (0.2 mm) between groups was considered clinically important was 95%. In matched groups of successfully treated

  8. Detection of pump degradation

    International Nuclear Information System (INIS)

    Greene, R.H.; Casada, D.A.; Ayers, C.W.

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented

  9. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  10. Pumps for nuclear industry

    International Nuclear Information System (INIS)

    Tanguy, L.

    1978-01-01

    In order to meet the requirements of nuclear industry for the transfer of corrosive, toxic, humidity sensitive or very pure gases, different types of pumps were developped and commercialized. Their main characteristics are to prevent pollution of the transfered fluid by avoiding any contact between this fluid and the lubricated parts of the machine, and to prevent a contamination of the atmosphere or of the fluid by a total tightness. Patellar pumps have been particularly developped because the metallic bellows are quite reliable and resistant in this configuration. Two types are described: patellar pumps without friction and barrel pumps whose pistons are provided with rings sliding in the cylinders without lubrication [fr

  11. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  12. Planetary Science with Balloon-Borne Telescopes

    Science.gov (United States)

    Kremic, Tibor; Cheng, Andy; Hibbitts, Karl; Young, Eliot

    2015-01-01

    The National Aeronautics and Space Administration (NASA) and the planetary science community have recently been exploring the potential contributions of stratospheric balloons to the planetary science field. A study that was recently concluded explored the roughly 200 or so science questions raised in the Planetary Decadal Survey report and found that about 45 of those questions are suited to stratospheric balloon based observations. In September of 2014, a stratospheric balloon mission called BOPPS (which stands for Balloon Observation Platform for Planetary Science) was flown out of Fort Sumner, New Mexico. The mission had two main objectives, first, to observe a number of planetary targets including one or more Oort cloud comets and second, to demonstrate the applicability and performance of the platform, instruments, and subsystems for making scientific measurements in support planetary science objectives. BOPPS carried two science instruments, BIRC and UVVis. BIRC is a cryogenic infrared multispectral imager which can image in the.6-5 m range using an HgCdTe detector. Narrow band filters were used to allow detection of water and CO2 emission features of the observed targets. The UVVis is an imager with the science range of 300 to 600 nm. A main feature of the UVVis instrument is the incorporation of a guide camera and a Fine Steering Mirror (FSM) system to reduce image jitter to less than 100 milliarcseconds. The BIRC instrument was used to image targets including Oort cloud comets Siding Spring and Jacques, and the dwarf planet 1 Ceres. BOPPS achieved the first ever earth based CO2 observation of a comet and the first images of water and CO2 of an Oort cloud comet (Jacques). It also made the first ever measurement of 1Ceres at 2.73 m to refine the shape of the infrared water absorption feature on that body. The UVVis instrument, mounted on its own optics bench, demonstrated the capability for image correction both from atmospheric disturbances as well as some

  13. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  14. Pneumothorax, music and balloons: A case series

    Directory of Open Access Journals (Sweden)

    Shiferaw Dejene

    2013-01-01

    Full Text Available We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation.

  15. Retrograde transurethral balloon dilation of the prostate

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Wasserman, N.F.; Lund, G.; Hulbert, J.; Hunter, D.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1986-01-01

    A series of patients with documented benign prostatic hypertrophy evaluated by urodynamic studies, voiding cystourethrography, retrograde urethrography, and MR imaging underwent dilation performed using a retrograde transurethral approach with 25-mm balloon dilators inflated at a pressure of 3-4 atm for 10 minutes. Immediately after the procedure, retrograde and voiding cystourethrography as well as MR imaging were performed. A Foley catheter was left in place for 24 hours. Complete relief of symptoms has occurred in all of the patients during the follow-up period. No significant complications other than transient hematuria resulted from the procedure. Results of the comparison studies and of MR imaging are discussed

  16. Resistive G-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Mondt, J.P.; Paris, R.B.

    1980-01-01

    A unified theory of the linear stability of the Roberts and Taylor type of resistive interchange and ballooning is presented. The effects of both parallel and perpendicular viscosity as well as of finite shear and finite β are included in a MHD treatment of the problem. Kinetic effects are also studied. The hybrid kinetic model with Vlasov ions and guiding center electrons has been appropriately generalized to allow for electron-ion collisions. The geometry is that of a plane slab with magnetic shear

  17. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  18. Amlodipine reduces AngII-induced aortic aneurysms and atherosclerosis in hypercholesterolemic mice.

    Directory of Open Access Journals (Sweden)

    Xiaofeng Chen

    Full Text Available The purpose of this study was to determine effects of amlodipine, a dihydropyridine calcium channel blocker, on development of angiotensin II (AngII-induced vascular pathologies.Male LDL receptor -/- mice were infused with vehicle, amlodipine (5 mg/kg/d, AngII (1,000 ng/kg/min, or AngII + amlodipine for 4 weeks through osmotic pumps (n=10/group. Mice were fed a saturated fat-enriched diet for 1 week prior to pump implantation and during 4 weeks of infusion. Infusion of amlodipine resulted in plasma concentrations of 32 ± 2 ng/ml and 27 ± 2 ng/ml for mice in saline + amlodipine and AngII + amlodipine groups, respectively. This infusion rate of amlodipine did not affect AngII-induced increases in systolic blood pressure. Three of 10 (30% mice infused with AngII died of aortic rupture, while aortic rupture did not occur in mice co-infused with AngII + amlodipine. Suprarenal aortic width and intimal area of ascending aortas were measured to define aortic aneurysms. In the absence of AngII infusion, amlodipine did not change suprarenal aortic width and ascending aortic area. Infusion of AngII led to profound increases of suprarenal aortic width (saline + vehicle versus AngII + vehicle: 0.86 ± 0.02 versus 1.72 ± 0.26 mm; P=0.0006, whereas co-infusion of AngII and amlodipine diminished abdominal dilation (1.02 ± 0.14 mm; P=0.003. As expected, AngII infusion increased mean intimal area of ascending aortas (saline + vehicle versus AngII + vehicle: 8.5 ± 0.3 versus 12.5 ± 1.1 mm(2; P=0.001, while co-infusion of AngII and amlodipine ablated dilation of the ascending aorta (8.6 ± 0.2 mm(2; P=0.03. Co-administration of amlodipine also significantly attenuated AngII-induced atherosclerosis in the thoracic region as quantified by percent lesion area (AngII + vehicle versus AngII + amlodipine: 5.8 ± 2.1 % versus 0.3 ± 0.1%; P=0.05.Amlodipine inhibited AngII-induced aortic aneurysms in both the abdominal and ascending regions, and atherosclerosis in

  19. Endoscopic Papillary Balloon Dilation with Large Balloon after Limited Sphincterotomy for Retrieval of Choledocholithiasis

    Science.gov (United States)

    Bang, Seungmin; Kim, Myoung Hwan; Park, Jeong Youp; Park, Seung Woo; Song, Si Young

    2006-01-01

    Endoscopic papillary balloon dilation (EBD) for choledocholithiasis is known to be comparable to endoscopic sphincterotomy (EST) especially in cases of small stones. With larger stones, EBD with conventional balloon, which have a diameter of 6-8 mm, was reported as less effective for extraction of stones. We evaluated the efficacy and complications of EBD with large balloons (10-15 mm) after limited EST for retrieval of choledocholithiasis. From February 2005, we have performed EBD with limited EST for retrieval of common bile duct (CBD) stones. The patients who admitted with hyperamylasemia and gallstone pancreatitis were excluded. In cases without CBD dilation, EPBD with 12 mm for 40 seconds was performed. And in cases with CBD dilation, we dilated the sphincters with 15 mm sized balloon for 40 seconds. Total 22 patients (11 of male) were performed EBD with limited EST for retrieval of CBD stones. The median diameter of the stones was 10 mm (5-25 mm). Ten cases had multiple stones and 6 cases periampullary diverticuli. Successful stone removal in the initial session of ERCP with EBD was accomplished in 16 patients (72.7%). And complete retrieval of bile duct stones was achieved in all patients with repeated ERCP. In the aspect of complications, any episodes of perforation, bleeding was not developed. Only one case of mild grade of post-procedural pancreatitis was noted. However, post-procedural hyperamylasemia was developed in 16 cases (68.2%). EBD with larger balloon seems to be a feasible and safe alternative technique for conventional EST in CBD stone extraction. PMID:17191309

  20. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. HIV infection and aortic stiffness.

    Science.gov (United States)

    Leite, Luisa Helena Maia; Cohen, Ariel; Boccara, Franck

    People living with human immunodeficiency virus (HIV) infection and receiving antiretroviral therapy now have the same life expectancy as the general population. However, they have a higher risk of atherosclerotic cardiovascular events because of a complex and polyfactorial vasculopathy, combining the effects of antiretroviral therapy, the HIV virus itself, immune activation, chronic inflammation and metabolic disturbances. Whether people living with HIV infection experience increased vascular aging compared with the general population remains controversial. To summarize current knowledge of the association between HIV infection and aortic stiffness as a marker of vascular aging. This review included 18 clinical studies in adult populations, published between 2009 and 2016, and identified on PubMed/MEDLINE or other databases. Search terms were aortic stiffness, arterial stiffness, vascular aging, pulse wave velocity and HIV. All 18 studies were observational, and compared groups infected (HIV+) and not infected (HIV-) with HIV. Ten studies (55%) reported no significant differences in aortic stiffness between HIV+ groups and age-matched HIV- control groups. The main reported determinants of aortic stiffness were age, blood pressure, smoking, metabolic syndrome and HIV-related variables, including CD4/CD8 ratio, current T-CD4 count CD4+ count < 200/mm 3 . We found discordant results regarding whether HIV+ patients had increased aortic stiffness compared with HIV- controls. However, HIV-related conditions were associated with vascular health. This association has been confirmed in recent prospective studies. There is emerging evidence that HIV itself and immune activity affect vascular health and the large arteries. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. The Evaluation of Endoscopic Balloon Dilation Treatment for

    Directory of Open Access Journals (Sweden)

    Shokri-Shirvani Javad

    2009-10-01

    Full Text Available Balloon dilatation of stricture is one of the new treatment methods among patients with gastric outlet obstruction (GOO. However, the prevalence and underlying etiologies of GOO in various populations are different. The goal of the present study was to determine the effectiveness of endoscopic balloon dilatation and factors that would affect its success rate patients with benign etiology for GOO. Forty-five patients with the symptoms of benign GOO were randomly selected. Gastric outlet was delineated using double channel videoendoscopy. The information of initial balloon dilation was collected from recorded files. Balloon dilatation was repeated during the mean follow up of 9.9 ± 5.8 months. The severity of gastric pain was measured immediately before balloon dilatation and one month after procedure and was rated on a 10 cm visual analogue scale. The mean age of patients was 43.7 ± 18.1 years and 86.7% of them were men. Furthermore, 71.1% were H pylori positive. Response rate to endoscopic balloon dilatation was 80% and 8 patients underwent surgical resection. Weight loss was more frequent in non-responding group. The pain severity was significantly reduced more in responding subjects. No meaningful relationships were found between the responses to balloon dilatation and positive H pylori and cigarette smoking. Endoscopic balloon dilation is safe and effective for most patients with benign gastric outlet obstruction and has favorable long-term outcome.

  3. The Balloon Foot ; A Rare Presentation Of Congenital Constricting ...

    African Journals Online (AJOL)

    We present a case of a rare manifestation of congenital constricting annular band (CAB) in the lower extremity resulting in a severe excessive swelling of the foot which we have termed Balloon foot. The ballooned foot is caused by a progressive deepening of the circumferential constriction into the soft tissue of the lower ...

  4. Scientific ballooning in the 20 th century; a historical perspective

    Science.gov (United States)

    Nishimura, J.

    Hess discovered the cosmic rays in 1912. Using a manned balloon, he found the altitude variation of the radiation. After this discovery, many balloon experiments were performed to explore the most mysterious radiation coming from outside of the earth during the 1920's to the 1930's. At the end of the 1940's, balloon systems were revolutionized by the use of new plastic films and telemetry systems. At almost the same time, highly sensitive nuclear emulsions were developed. Balloon exposures of emulsions brought us new discoveries of the heavy primaries in cosmic rays. Extensive studies with nuclear emulsions discovered high-energy phenomena and new particles between the end of 1940's to the 1960's. At the same time, in various countries, experiments with more sophisticated electronic devices were begun together with ingenious work on balloon technology. Inventions were made in the areas of designing, manufacturing, materials, telemetry systems for balloons and long duration flight systems etc. Several permanent launching stations were established in various countries in the 1960's Here, I review the development of essential technologies in scientific ballooning, and their value in contributing to the growth of space physics. As the future prospect, I stress the point that scientific ballooning is indispensable and a most cost-effective way to explore space astrophysics and Earth science, in addition to the preparation of satellite and the space station experiments.

  5. Coronary artery angioplasty with a helical autoperfusion balloon catheter

    NARCIS (Netherlands)

    Gurbel, PA; Anderson, RD; vanBoven, AJ; denHeijer, P

    The initial in-hospital and long-term clinical experience with a helical autoperfusion balloon catheter in the treatment of coronary artery disease is reported, This new catheter design allows blood to flow passively around the inflated balloon through a protected helical channel molded into the

  6. External caps: An approach to stress reduction in balloons

    Science.gov (United States)

    Hazlewood, K. H.

    Recent findings of the catastrophic balloon failures investigation in the U.S.A. indicate that very large gross inflations, in balloons using present design philosophy, over-stress currently available materials. External caps are proposed as an economic approach to reducting those stresses to an acceptable level.

  7. Increase Carotid Flow by Double Sheath Connection Technique to Reduce Cerebral Ischemia for Transcatheter Aortic Valve Implantation through Transcarotid Approach.

    Science.gov (United States)

    Tsai, Richard; Chen, I-Ming; Chen, Po-Lin; Leu, Hsin-Bang; Chen, Ying-Hwa; Chang, Hsiao-Huang

    2018-04-06

    Transcarotid transcatheter aortic valve implantation (TAVI) is one alternative approach if unfavorable femoral access. However, this approach may cause cerebral vascular accidents (CVAs) by temporarily occluding common carotid artery (CCA). The purpose of this study is to develop a new method reducing cerebral ischemia during transcarotid TAVI. We inserted an 8- and 18-Fr. sheath in CCA with tip toward brain and aortic arch, respectively, and connected their side arms to create a bypass flow. Medtronic CoreValve was then delivered and deployed in position after pre-TAVI balloon dilatation. Three patients received this implantation. There were no CVAs or transient ischemic attacks (TIAs) after the procedure and all patients had been followed up uneventfully for 1 year. Our technique is feasible and potentially reduces stroke in transcarotid TAVI.

  8. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  9. Metabolic and hemodynamic effects of saline infusion to maintain volemia on temporary abdominal aortic occlusion

    Directory of Open Access Journals (Sweden)

    Fábio Ferreira Amorim

    2002-10-01

    Full Text Available OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10 and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10. All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

  10. Beyond Pressure Gradients: The Effects of Intervention on Heart Power in Aortic Coarctation.

    Science.gov (United States)

    Fernandes, Joao Filipe; Goubergrits, Leonid; Brüning, Jan; Hellmeier, Florian; Nordmeyer, Sarah; da Silva, Tiago Ferreira; Schubert, Stephan; Berger, Felix; Kuehne, Titus; Kelm, Marcus

    2017-01-01

    In aortic coarctation, current guidelines recommend reducing pressure gradients that exceed given thresholds. From a physiological standpoint this should ideally improve the energy expenditure of the heart and thus prevent long term organ damage. The aim was to assess the effects of interventional treatment on external and internal heart power (EHP, IHP) in patients with aortic coarctation and to explore the correlation of these parameters to pressure gradients obtained from heart catheterization. In a collective of 52 patients with aortic coarctation 25 patients received stenting and/or balloon angioplasty, and 20 patients underwent MRI before and after an interventional treatment procedure. EHP and IHP were computed based on catheterization and MRI measurements. Along with the power efficiency these were combined in a cardiac energy profile. By intervention, the catheter gradient was significantly reduced from 21.8±9.4 to 6.2±6.1mmHg (ptreatment of coarctation resulted in a decrease in IHP. Pressure gradients, as the most widespread clinical parameters in coarctation, did not show any correlation to changes in EHP or IHP. This raises the question of whether they should be the main focus in coarctation interventions. Only patients with high IHP of above 5W showed improvement in IHP and power efficiency after the treatment procedure. clinicaltrials.gov NCT02591940.

  11. Aortic intramural hematoma : assessment of clinical and radiological features in comparison to acute aortic dissection

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Hwang, Jae Cheol; Lee, Jin Seong; Kang, Duk Hyun; Song, Jae Kwan; Song, Koun Sik; Lim, Tae Hwan

    1996-01-01

    To compare the clinical and radiological features of aortic intramural hematoma(IMH) to those of acute aortic dissection(AD). We analyzed the clinical and radiological features of 12 patients with aortic IMH and 43 patients with acute AD. In aortic IMH, the diagnoses were made by means of both CT and transesophageal echocardiography(TEE) and included two surgically proven cases. In acute AD, the diagnoses were made by means of CT and TEE and included 21 surgically proven cases. We compared patients ages, etiologies, the extent of the disease, the presence or absence of aortic branch involvement, complications, and outcomes. Aortic IMH tended to develop in older patients (67.8±7.9 vs. 50.4±13.4, P .05). In aortic IMH, there was no involvement of aortic branches, whereas in acute AD, 14(33%) patients showed involvement of one or more aortic branches. Complications of aortic IMH included pericardial effusion (n=2) and pleural effusion (n=4);in acute AD, pericardial effusion (n=7), pleural effusion (n=4), aortic insufficiency (n=8), cerebral infarction (n=3), renal infarction (n=4) and spinal infarction (n=1) were seen. There was one (8%) death due to aortic IMH and ten (23%) deaths due to acute AD (p<.01). Aortic IMH is characterized by its occurrence in older patients with hypertension, a less frequent incidence of complications, and a more favorable outcome than acute AD

  12. One stage surgical treatment of aortic valve disease and aortic coarctation with aortic bypass grafting through the diaphragm and aortic valve replacement.

    Science.gov (United States)

    Yu, Zipu; Wu, Shengjun; Li, Chengchen; Zou, Yu; Ma, Liang

    2015-11-10

    To validate ascending aorta-lower abdominal aorta bypass grafting treatment for patients with descending aortic coarctation and an aortic valve disease. The three patients in whom a descending atypical aortic coarctation was associated with an aortic valve disease were treated with one stage surgical treatment with aortic bypass grafting through the diaphragm and aortic valve replacement in our heart center. Operative technique consisted of performing ascending aorta-lower abdominal aorta bypass grafting through diaphragm muscle and implementing aortic valve replacement. The mean time for extracorporeal circulation and occluding clamp of aorta was recorded. Blood pressure data for pre- and post-operation was measured in the limbs. Computer-enhanced transvenous angiograms of pre- and post-operation were applied for detection of aortic stenosis. The other adverse events were noticed in outpatient service during a follow-up period. The mean extracorporeal circulation time was 54 ± 11 min. The mean time for occluding clamp of aorta was 34 ± 6 min. An arterial pressure gradient was totally corrected after surgical treatment. Post-operation computer-enhanced transvenous angiograms showed the grafts to be open with a fluent flow. The patients had no gastrointestinal tract complications. No adverse event was noticed during a follow-up period in outpatient service. Treatment of ascending aorta-lower abdominal aorta bypass is advisable for patients with descending aortic coarctation and an aortic valve disease.

  13. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.

    1988-01-01

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  14. Slurry pump compatibility testing

    International Nuclear Information System (INIS)

    Mickalonis, J.I.

    2000-01-01

    The SRTC/Materials Technology Section (MTS) performed an evaluation of the compatibility of four slurry pump materials of construction in high level waste supernate environments. These tests were performed because of recent binding of the pump shafts after exposure to supernate in Tank 8F

  15. Water Treatment Technology - Pumps.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on pumps provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pumps in plant and distribution systems, pump…

  16. Pump apparatus including deconsolidator

    Energy Technology Data Exchange (ETDEWEB)

    Sonwane, Chandrashekhar; Saunders, Timothy; Fitzsimmons, Mark Andrew

    2014-10-07

    A pump apparatus includes a particulate pump that defines a passage that extends from an inlet to an outlet. A duct is in flow communication with the outlet. The duct includes a deconsolidator configured to fragment particle agglomerates received from the passage.

  17. NEUTRONIC REACTOR FUEL PUMP

    Science.gov (United States)

    Cobb, W.G.

    1959-06-01

    A reactor fuel pump is described which offers long life, low susceptibility to radiation damage, and gaseous fission product removal. An inert-gas lubricated bearing supports a journal on one end of the drive shsft. The other end has an impeller and expansion chamber which effect pumping and gas- liquid separation. (T.R.H.)

  18. Spectrum of the ballooning Schroedinger equation

    International Nuclear Information System (INIS)

    Dewar, R.L.

    1997-01-01

    The ballooning Schroedinger equation (BSE) is a model equation for investigating global modes that can, when approximated by a Wentzel-Kramers-Brillouin (WKB) ansatz, be described by a ballooning formalism locally to a field line. This second order differential equation with coefficients periodic in the independent variable θ k is assumed to apply even in cases where simple WKB quantization conditions break down, thus providing an alternative to semiclassical quantization. Also, it provides a test bed for developing more advanced WKB methods: e.g. the apparent discontinuity between quantization formulae for open-quotes trappedclose quotes and open-quotes passingclose quotes modes, whose ray paths have different topologies, is removed by extending the WKB method to include the phenomena of tunnelling and reflection. The BSE is applied to instabilities with shear in the real part of the local frequency, so that the dispersion relation is inherently complex. As the frequency shear is increased, it is found that trapped modes go over to passing modes, reducing the maximum growth rate by averaging over θ k

  19. Circulation pump mounting

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    The suspension is described of nuclear reactor circulating pumps enabling their dilatation with a minimum reverse force consisting of spacing rods supported with one end in the anchor joints and provided with springs and screw joints engaging the circulating pump shoes. The spacing rods are equipped with side vibration dampers anchored in the shaft side wall and on the body of the circulating pump drive body. The negative reverse force F of the spacing rods is given by the relation F=Q/l.y, where Q is the weight of the circulating pump, l is the spatial distance between the shoe joints and anchor joints, and y is the deflection of the circulating pump vertical axis from the mean equilibrium position. The described suspension is advantageous in that that the reverse force for the deflection from the mean equilibrium position is minimal, dynamic behaviour is better, and construction costs are lower compared to suspension design used so far. (J.B.)

  20. Abdominal aortic aneurysms.

    Science.gov (United States)

    Lindholt, Jes Sanddal

    2010-12-01

    Although the number of elective operations for abdominal aortic aneurysms (AAA) is increasing, the sex- and age-standardised mortality rate of AAAs continues to rise, especially among men aged 65 years or more. The lethality of ruptured AAA continues to be 80-95%, compared with 5-7% by elective surgery of symptomfree AAA. In order to fulfil all WHO, European, and Danish criteria for screening, a randomised hospitalbased screening trial of 12,639 65-73 year old men in Viborg County (Denmark) was initiated in 1994. It seemed that US screening is a valid, suitable and acceptable method of screening. The acceptance rate was 77%, and 95% accept control scans. Furthermore, persons at the highest risk of having an AAA attend screening more frequently. We found that 97% of the interval cases developed from aortas that initially measured 2.5-2.9 cm - i.e. approx. only 5% attenders need re-screening at 5-year intervals. Two large RCTs have given clear indications of operation. Survivors of surgery enjoy the same quality of life as the background population, and only 2-5% of patients refuse an offer of surgery. Early detection seems relevant since the cardiovascular mortality is more than 4 times higher in AAA patients without previous hospital discharge diagnoses due to cardiovascular disease than among similar men without AAA. The absolute risk difference after 5 years was 16%. So, they will benefit from general cardiovascular preventive action as smoking cessation, statins and low-dose aspirin, which could inhibit further AAA progression. All 4 existing RCTs point in the same direction, viz. in favour of screening of men aged 65 and above. We found that screening significantly reduced AAA-related mortality by 67% within the first five years (NNT = 352). Restriction of screening to men with previous cardiovascular or pulmonary hospital discharge diagnoses would request only 27% of the relevant male population study to be invited, but would only have prevented 46.7% of the

  1. Supra-annular structure assessment for self-expanding transcatheter heart valve size selection in patients with bicuspid aortic valve.

    Science.gov (United States)

    Liu, Xianbao; He, Yuxin; Zhu, Qifeng; Gao, Feng; He, Wei; Yu, Lei; Zhou, Qijing; Kong, Minjian; Wang, Jian'an

    2018-04-01

    To explore assessment of supra-annular structure for self-expanding transcatheter heart valve (THV) size selection in patients with bicuspid aortic stenosis (AS). Annulus-based device selection from CT measurement is the standard sizing strategy for tricuspid aortic valve before transcatheter aortic valve replacement (TAVR). Because of supra-annular deformity, device selection for bicuspid AS has not been systemically studied. Twelve patients with bicuspid AS who underwent TAVR with self-expanding THVs were included in this study. To assess supra-annular structure, sequential balloon aortic valvuloplasty was performed in every 2 mm increments until waist sign occurred with less than mild regurgitation. Procedural results and 30 day follow-up outcomes were analyzed. Seven patients (58.3%) with 18 mm; three patients (25%) with sequential 18 mm, 20 mm; and only two patients (16.7%) with sequential 18 mm, 20 mm, and 22 mm balloon sizing were performed, respectively. According to the results of supra-annular assessment, a smaller device size (91.7%) was selected in all but one patient compared with annulus based sizing strategy, and the outcomes were satisfactory with 100% procedural success. No mortality and 1 minor stroke were observed at 30 d follow-up. The percentage of NYHA III/IV decreased from 83.3% (9/12) to 16.7% (2/12). No new permanent pacemaker implantation and no moderate or severe paravalvular leakage were found. A supra-annular structure based sizing strategy is feasible for TAVR in patients with bicuspid AS. © 2018 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  2. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  3. BWR series pump recirculation system

    International Nuclear Information System (INIS)

    Dillmann, C.W.

    1992-01-01

    This patent describes a recirculation system for driving reactor coolant water contained in an annular downcomer defined between a boiling water reactor vessel and a reactor core spaced radially inwardly therefrom. It comprises a plurality of circumferentially spaced second pumps disposed in the downcomer, each including an inlet for receiving from the downcomer a portion of the coolant water as pump inlet flow, and an outlet for discharging the pump inlet flow pressurized in the second pump as pump outlet flow; and means for increasing pressure of the pump inlet flow at the pump inlet including a first pump disposed in series flow with the second pump for first receiving the pump inlet flow from the downcomer and discharging to the second pump inlet flow pressurized in the first pump

  4. The role of elastomeric pumps in postoperative analgesia in orthopaedics and factors affecting their flow rate.

    Science.gov (United States)

    Theodorides, Anthony Andreas

    2017-12-01

    Elastomeric pumps are mechanical devices composed of an elastomeric balloon reservoir into which the drug to be infused is stored, a protective casing (used by some manufacturers), a flow controller and a wound catheter. In orthopaedics they are used to provide continuous local infiltration analgesia. In this way patients rely less on other routes of analgesia and thus avoid their systemic side effects. Studies have shown good response to analgesia with these pumps for the first 24 hours but their benefit is not as clear at 48 and 72 hours. There are numerous factors that affect the flow rate of elastomeric pumps. Some are inherent to all elastomeric pumps such as: the pressure exerted by the elastomeric balloon, catheter size, the vertical height of the pump in relation to the wound, viscosity and partial filling. There are also other factors which vary according to the manufacturer such as: the optimal temperature to obtain the desired flow rate as this directly affects viscosity, the dialysate that the analgesic drug is mixed with (ie normal saline or 5% dextrose), and the storage conditions of the fluid to be infused. It is thus essential to follow the clinical guidelines provided by the manufacturer in order to obtain the desired flow rate. Copyright the Association for Perioperative Practice.

  5. Indexing aortic valve area by body surface area increases the prevalence of severe aortic stenosis

    DEFF Research Database (Denmark)

    Jander, Nikolaus; Gohlke-Bärwolf, Christa; Bahlmann, Edda

    2014-01-01

    To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are......To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are...

  6. Large aortic root pseudoaneurysm occurring late after aortic root repair and valve replacement for endocarditis

    Directory of Open Access Journals (Sweden)

    Prashanth Panduranga

    2013-01-01

    Full Text Available A 68-year-old male presented with Group B Streptococcus aortic valve (AV endocarditis with aortic root abscess and refractory sepsis. An emergency cardiac surgery was performed with root abscess drainage, excision and debridement of necrotic tissue, reconstruction of annulus, and AV replacement. Fifteen months later he presented with a huge aortic root pseudoaneurysm (PA. This case illustrates late occurrence of aortic root PA following AV surgery for endocarditis.

  7. The Balloon-Based Manometry Evaluation of Swallowing in Patients with Amyotrophic Lateral Sclerosis

    Directory of Open Access Journals (Sweden)

    Jerzy Tomik

    2017-03-01

    Full Text Available The aim of the study was to analyse the disturbances of the oro-pharyngeal swallowing phase of dysphagia in amyotrophic lateral sclerosis (ALS patients with the use of specific manometric measurements and to evaluate their plausible association with the duration of the disease. Seventeen patients with ALS were evaluated with manometric examinations of the oral and pharyngeal part of the gastrointestinal tract. Tests were carried out by using the oesophageal balloon-based method with four balloon transducers located 5 cm away from each other. The following manometric parameters were analysed: the base of tongue contraction (BTC and the upper oesophageal sphincter pressure (UESP, and the hypopharyngeal suction pump (HSP as well as the oro-pharyngeal, pharyngeal and hypopharyngeal transit time and average pharyngeal bolus velocity (oropharyngeal transit time (OTT, pharyngeal transit time (PTT, hypopharyngeal transit time (HTT and average pharyngeal bolus velocity (APBV, respectively. Manomatric examinations during swallowing in patients with ALS showed significant weakness of BTC, a decrease of HSP and a decrease of the velocity of bolus transit inside the pharynx which were particularly marked between the first and the third examination. Manometric examinations of the oro-pharyngeal part of the gastrointestinal tract are useful and supportive methods in the analysis of swallowing disturbances in ALS patients.

  8. Aorta Balloon Occlusion in Trauma: Three Cases Demonstrating Multidisciplinary Approach Already on Patient’s Arrival to the Emergency Room

    Energy Technology Data Exchange (ETDEWEB)

    Hörer, Tal M., E-mail: tal.horer@orebroll.se [Örebro University, Department of Cardiothoracic and Vascular Surgery, Örebro University Hospital (Sweden); Hebron, Dan [Hillel Yaffe Medical Center, Department of Radiology (Israel); Swaid, Forat [Bnai-Zion Medical Center, Department of General Surgery (Israel); Korin, Alexander [Hillel Yaffe Medical Center, Trauma Unit (Israel); Galili, Offer [Hillel Yaffe Medical Center, Department of Vascular Surgery (Israel); Alfici, Ricardo [Hillel Yaffe Medical Center, Surgical Division (Israel); Kessel, Boris [Hillel Yaffe Medical Center, Trauma Unit (Israel)

    2016-02-15

    PurposeTo describe the usage of aortic balloon occlusion (ABO), based on a multidisciplinary approach in severe trauma patients, emphasizing the role of the interventional radiologist in primary trauma care.MethodsWe briefly discuss the relevant literature, the technical aspects of ABO in trauma, and a multidisciplinary approach to the bleeding trauma patient. We describe three severely injured trauma patients for whom ABO was part of initial trauma management.ResultsThree severely injured multi-trauma patients were treated by ABO as a bridge to surgery and embolization. The procedures were performed by an interventional radiologist in the early stages of trauma management.ConclusionsThe interventional radiologist and the multidisciplinary team approach can be activated already on severe trauma patient arrival. ABO usage and other endovascular methods are becoming more widely spread, and can be used early in trauma management, without delay, thus justifying the early activation of this multidisciplinary approach.

  9. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  10. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  11. Cervical aortic arch and a new type of double aortic arch. Report of a case.

    Science.gov (United States)

    Cornali, M; Reginato, E; Azzolina, G

    1976-09-01

    A case of cervical aortic arch is reported. To the best of our knowledge, it is the first to be associated with a serious intracardiac anomaly. In addition, it is part of a new type of double aortic arch, caused by failure of reabsorption of both dorsal aortic roots and persistence of the fourth right and second (or third) left branchial arches.

  12. Ascending aortic diameters in congenital aortic stenosis: cardiac magnetic resonance versus transthoracic echocardiography

    NARCIS (Netherlands)

    Linde, D. van der; Rossi, A. de; Yap, S.C.; McGhie, J.S.; Bosch, A.E. van den; Kirschbaum, S.W.; Russo, B.; Dijk, A.P.J. van; Moelker, A.; Krestin, G.P.; Geuns, R.J. van; Roos-Hesselink, J.W.

    2013-01-01

    OBJECTIVES/BACKGROUND: Congenital aortic stenosis (AS) is the most common obstructive left heart lesion in the young adult population and often complicated by aortic dilatation. Our objective was to evaluate accuracy of aortic imaging with transthoracic echocardiography (TTE) compared with cardiac

  13. Detecting Seismic Infrasound Signals on Balloon Platforms

    Science.gov (United States)

    Krishnamoorthy, S.; Komjathy, A.; Cutts, J. A.; Pauken, M.; Garcia, R.; Mimoun, D.; Jackson, J. M.; Kedar, S.; Smrekar, S. E.; Hall, J. L.

    2017-12-01

    The determination of the interior structure of a planet requires detailed seismic investigations - a process that entails the detection and characterization of seismic waves due to geological activities (e.g., earthquakes, volcanoes, etc.). For decades, this task has primarily been performed on Earth by an ever-expanding network of terrestrial seismic stations. However, on planets such as Venus, where the surface pressure and temperature can reach as high as 90 atmospheres and 450 degrees Celsius respectively, placing seismometers on the planet's surface poses a vexing technological challenge. However, the upper layers of the Venusian atmosphere are more benign and capable of hosting geophysical payloads for longer mission lifetimes. In order to achieve the aim of performing geophysical experiments from an atmospheric platform, JPL and its partners (ISAE-SUPAERO and California Institute of Technology) are in the process of developing technologies for detection of infrasonic waves generated by earthquakes from a balloon. The coupling of seismic energy into the atmosphere critically depends on the density differential between the surface of the planet and the atmosphere. Therefore, the successful demonstration of this technique on Earth would provide ample reason to expect success on Venus, where the atmospheric impedance is approximately 60 times that of Earth. In this presentation, we will share results from the first set of Earth-based balloon experiments performed in Pahrump, Nevada in June 2017. These tests involved the generation of artificial sources of known intensity using a seismic hammer and their detection using a complex network of sensors, including highly sensitive micro-barometers suspended from balloons, GPS receivers, geophones, microphones, and seismometers. This experiment was the first of its kind and was successful in detecting infrasonic waves from the earthquakes generated by the seismic hammer. We will present the first comprehensive analysis

  14. Microcontroller uses in Long-Duration Ballooning

    Science.gov (United States)

    Jones, Joseph

    This paper discusses how microcontrollers are being utilized to fulfill the demands of long duration ballooning (LDB) and the advantages of doing so. The Columbia Scientific Balloon Facility (CSBF) offers the service of launching high altitude balloons (120k ft) which provide an over the horizon telemetry system and platform for scientific research payloads to collect data. CSBF has utilized microcontrollers to address multiple tasks and functions which were previously performed by more complex systems. A microcontroller system has been recently developed and programmed in house to replace our previous backup navigation system which is used on all LDB flights. A similar microcontroller system was developed to be independently launched in Antarctica before the actual scientific payload. This system's function is to transmit its GPS position and a small housekeeping packet so that we can confirm the upper level float winds are as predicted from satellite derived models. Microcontrollers have also been used to create test equipment to functionally check out the flight hardware used in our telemetry systems. One test system which was developed can be used to quickly determine if our communication link we are providing for the science payloads is functioning properly. Another system was developed to provide us with the ability to easily determine the status of one of our over the horizon communication links through a closed loop system. This test system has given us the capability to provide more field support to science groups than we were able to in years past. The trend of utilizing microcontrollers has taken place for a number of reasons. By using microcontrollers to fill these needs, it has given us the ability to quickly design and implement systems which meet flight critical needs, as well as perform many of the everyday tasks in LDB. This route has also allowed us to reduce the amount of time required for personnel to perform a number of the tasks required

  15. Hybrid treatment of penetrating aortic ulcer

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Juan Antonio Herrero; Martins-Romeo, Daniela de Araujo; Escudero, Carlos Caparros; Falcon, Maria del Carmen Prieto; Batista, Vinicius Bianchi, E-mail: jaherrero5@hotmail.com [Unidade de Gestao Clinica (UGC) de Diagnostico por Imagem - Hosppital Universitario Virgen Macarena, Sevilha (Spain); Vazquez, Rosa Maria Lepe [Unit of Radiodiagnosis - Hospital Nuestra Senora de la Merced, Osuna, Sevilha (Spain)

    2015-05-15

    Penetrating atherosclerotic aortic ulcer is a rare entity with poor prognosis in the setting of acute aortic syndrome. In the literature, cases like the present one, located in the aortic arch, starting with chest pain and evolving with dysphonia, are even rarer. The present report emphasizes the role played by computed tomography in the diagnosis of penetrating atherosclerotic ulcer as well as in the differentiation of this condition from other acute aortic syndromes. Additionally, the authors describe a new therapeutic approach represented by a hybrid endovascular surgical procedure for treatment of the disease. (author)

  16. Hybrid treatment of penetrating aortic ulcer

    International Nuclear Information System (INIS)

    Lara, Juan Antonio Herrero; Martins-Romeo, Daniela de Araujo; Escudero, Carlos Caparros; Falcon, Maria del Carmen Prieto; Batista, Vinicius Bianchi; Vazquez, Rosa Maria Lepe

    2015-01-01

    Penetrating atherosclerotic aortic ulcer is a rare entity with poor prognosis in the setting of acute aortic syndrome. In the literature, cases like the present one, located in the aortic arch, starting with chest pain and evolving with dysphonia, are even rarer. The present report emphasizes the role played by computed tomography in the diagnosis of penetrating atherosclerotic ulcer as well as in the differentiation of this condition from other acute aortic syndromes. Additionally, the authors describe a new therapeutic approach represented by a hybrid endovascular surgical procedure for treatment of the disease. (author)

  17. Stunning and Right Ventricular Dysfunction Is Induced by Coronary Balloon Occlusion and Rapid Pacing in Humans: Insights From Right Ventricular Conductance Catheter Studies.

    Science.gov (United States)

    Axell, Richard G; Giblett, Joel P; White, Paul A; Klein, Andrew; Hampton-Til, James; O'Sullivan, Michael; Braganza, Denise; Davies, William R; West, Nick E J; Densem, Cameron G; Hoole, Stephen P

    2017-06-06

    We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  18. A prospective, randomised trial of transapical transcatheter aortic valve implantation vs. surgical aortic valve replacement in operable elderly patients with aortic stenosis

    DEFF Research Database (Denmark)

    Nielsen, Hans Henrik Møller; Klaaborg, Kaj E; Nissen, Henrik

    2012-01-01

    In a prospective randomised trial we aimed to compare transapical transcatheter aortic valve implantation (a-TAVI) with surgical aortic valve replacement (SAVR) in operable elderly patients.......In a prospective randomised trial we aimed to compare transapical transcatheter aortic valve implantation (a-TAVI) with surgical aortic valve replacement (SAVR) in operable elderly patients....

  19. Rectal Balloon for the Immobilization of the Prostate Internal Motion

    International Nuclear Information System (INIS)

    Lee, Sang Kyu; Beak, Jong Geal; Kim, Joo Ho; Jeon, Byong Chul; Cho, Jeong Hee; Kim, Dong Wook; Song, Tae Soo; Cho, Jae Ho; Na, Soo Kyong

    2005-01-01

    The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning same repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal balloon position and verified the isodose distribution of rectum wall at closed prostate. Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficient for treated prostate cancer patients.

  20. Graph-Based Path-Planning for Titan Balloons

    Science.gov (United States)

    Blackmore, Lars James; Fathpour, Nanaz; Elfes, Alberto

    2010-01-01

    A document describes a graph-based path-planning algorithm for balloons with vertical control authority and little or no horizontal control authority. The balloons are designed to explore celestial bodies with atmospheres, such as Titan, a moon of Saturn. The algorithm discussed enables the balloon to achieve horizontal motion using the local horizontal winds. The approach is novel because it enables the balloons to use arbitrary wind field models. This is in contrast to prior approaches that used highly simplified wind field models, such as linear, or binary, winds. This new approach works by discretizing the space in which the balloon operates, and representing the possible states of the balloon as a graph whose arcs represent the time taken to move from one node to another. The approach works with arbitrary wind fields, by looking up the wind strength and direction at every node in the graph from an arbitrary wind model. Having generated the graph, search techniques such as Dijkstra s algorithm are then used to find the set of vertical actuation commands that takes the balloon from the start to the goal in minimum time. In addition, the set of reachable locations on the moon or planet can be determined.

  1. A Survey of Titan Balloon Concepts and Technology Status

    Science.gov (United States)

    Hall, Jeffery L.

    2011-01-01

    This paper surveys the options for, and technology status of, balloon vehicles to explore Saturn's moon Titan. A significant amount of Titan balloon concept thinking and technology development has been performed in recent years, particularly following the spectacular results from the descent and landing of the Huygens probe and remote sensing observations by the Cassini spacecraft. There is widespread recognition that a balloon vehicle on the next Titan mission could provide an outstanding and unmatched capability for in situ exploration on a global scale. The rich variety of revealed science targets has combined with a highly favorable Titan flight environment to yield a wide diversity of proposed balloon concepts. The paper presents a conceptual framework for thinking about balloon vehicle design choices and uses it to analyze various Titan options. The result is a list of recommended Titan balloon vehicle concepts that could perform a variety of science missions, along with their projected performance metrics. Recent technology developments for these balloon concepts are discussed to provide context for an assessment of outstanding risk areas and technological maturity. The paper concludes with suggestions for technology investments needed to achieve flight readiness.

  2. Ballooning modes or Fourier modes in a toroidal plasma?

    International Nuclear Information System (INIS)

    Connor, J.W.; Taylor, J.B.

    1987-01-01

    The relationship between two different descriptions of eigenmodes in a torus is investigated. In one the eigenmodes are similar to Fourier modes in a cylinder and are highly localized near a particular rational surface. In the other they are the so-called ballooning modes that extend over many rational surfaces. Using a model that represents both drift waves and resistive interchanges the transition from one of these structures to the other is investigated. In this simplified model the transition depends on a single parameter which embodies the competition between toroidal coupling of Fourier modes (which enhances ballooning) and variation in frequency of Fourier modes from one rational surface to another (which diminishes ballooning). As the coupling is increased each Fourier mode acquires a sideband on an adjacent rational surface and these sidebands then expand across the radius to form the extended mode described by the conventional ballooning mode approximation. This analysis shows that the ballooning approximation is appropriate for drift waves in a tokamak but not for resistive interchanges in a pinch. In the latter the conventional ballooning effect is negligible but they may nevertheless show a ballooning feature. This is localized near the same rational surface as the primary Fourier mode and so does not lead to a radially extended structure

  3. Surgery for acute Type I aortic dissection without resection of supra-aortic entry sites leads to unfavourable aortic remodelling.

    Science.gov (United States)

    Heo, Woon; Song, Suk-Won; Lee, Kwang-Hun; Lee, Shin-Young; Kim, Tae-Hoon; Baek, Min-Young; Yoo, Kyung-Jong

    2018-01-29

    This study aimed to evaluate the impact of remnant re-entries in arch branches on postoperative change in the aortic arch and descending aortic diameters and the rate of major adverse aortic events. Between January 2010 and December 2016, 249 patients underwent surgery for acute Type I aortic dissection. Patients who underwent total arch replacement, had Marfan syndrome or had intramural haematoma were excluded. Seventy-two patients with predischarge and follow-up computed tomography scans were enrolled. Patients with and without re-entries in the arch branches after surgery were assigned to the supra-aortic entry (SAE, n = 21) and no supra-aortic entry (n = 51) groups, respectively. Diameters were measured at 7 levels: the innominate artery, left common carotid artery, left subclavian artery, 20 mm distal to the left subclavian artery, pulmonary artery bifurcation, coeliac axis and maximal diameter of the descending thoracic aorta. Growth rates at the levels of the pulmonary artery bifurcation and 20 mm distal to the left subclavian artery were significantly higher in the SAE group than in the no supra-aortic entry group. The rate of freedom from major adverse aortic events (annual growth >5 mm or maximal diameter of the descending thoracic aorta >50 mm) at 5 years was significantly higher in the no supra-aortic entry group than in the SAE group. Remnant SAE leads to unfavourable aortic remodelling after acute Type I aortic dissection repair. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Aortic dilatation in patients with prosthetic aortic valve: comparison of MRI and echocardiography.

    Science.gov (United States)

    von Knobelsdorff-Brenkenhoff, Florian; Rudolph, André; Wassmuth, Ralf; Abdel-Aty, Hassan; Schulz-Menger, Jeanette

    2010-05-01

    Patients with prosthetic aortic valve have an increased risk for aortic dissection, which rises further with growing aortic diameters. Thus, accurate aortic monitoring is required. As transthoracic echocardiography (TTE), the current clinical standard, is frequently restricted to the proximal ascending aorta, the use of two-dimensional cardiovascular magnetic resonance (2D-CMR) in transverse orientation was investigated as a screening tool to assess ascending aortic dimensions. Fast, non-contrast-enhanced, non-breath-hold, steady-state free-precession (SSFP) sequences (1.5 Tesla, slice thickness 7 mm, gap 1.8 mm, scan time 10-15 s) were applied to image the thorax in transverse planes. To test the accuracy of aortic dimensions obtained in this way, comparison was made to contrast-enhanced three-dimensional MR angiography (3D-MRA) as the 'gold standard' in 30 patients with aortic or aortic valve disease. After validation, transverse 2D-CMR was used to assess ascending aortic dimensions in 65 patients with aortic bioprostheses, and the results were compared to those acquired with TTE. Data acquired with both 2D-CMR and 3D-MRA agreed well when assessing ascending aortic diameters (r = 0.99; p 2.1 cm/m2) was present in 38.5% of 2D-CMR cases and in 11.5% of TTE cases. The intra- and inter-observer variabilities to assess aortic dimensions by 2D-CMR were 2.1 +/- 1.9% and 4.3 +/- 3.7%, respectively. Imaging of the complete thorax in transverse orientation using fast, non-contrast-enhanced SSFP images provided an accurate and reliable approach to screen for aortic dilatation. In patients with aortic bioprostheses, 2D-CMR revealed a high prevalence of aortic dilatation, which was considerably underestimated by TTE.

  5. N-dependence of ballooning instabilities

    International Nuclear Information System (INIS)

    Dewar, R.L.; Manickam, J.; Grimm, R.C.; Chance, M.S.

    1980-05-01

    The critical β for stability against ideal hydromagnetic internal ballooning modes as a function of toroidal mode number, n, is calculated for two different equilibrium sequences by use of a finite element technique (n less than or equal to 20), and a WKB formalism (n greater than or equal to 5). The agreement between the two methods is good in the overlap region 5 approx.less than or equal to n approx. less than or equal to 20. The WKB formula reduces to the 1/n correction at very high n, but is much more accurate at moderate n. The critical β vs n curves exhibit oscillatory structure at low n, but in both sequences the lower bound on β/sub c/ approx. 5%. For reactor parameters, finite Larmor radius effects are not expected to have a large effect on this β-limitation

  6. High Energy Antimatter Telescope (HEAT) Balloon Experiment

    Science.gov (United States)

    Beatty, J. J.

    1995-01-01

    This grant supported our work on the High Energy Antimatter Telescope(HEAT) balloon experiment. The HEAT payload is designed to perform a series of experiments focusing on the cosmic ray positron, electron, and antiprotons. Thus far two flights of the HEAT -e+/- configuration have taken place. During the period of this grant major accomplishments included the following: (1) Publication of the first results of the 1994 HEAT-e+/- flight in Physical Review Letters; (2) Successful reflight of the HEAT-e+/- payload from Lynn Lake in August 1995; (3) Repair and refurbishment of the elements of the HEAT payload damaged during the landing following the 1995 flight; and (4) Upgrade of the ground support equipment for future flights of the HEAT payload.

  7. Early results of valve-sparing ascending aortic replacement in type A aortic dissection and aortic insufficiency

    Directory of Open Access Journals (Sweden)

    М. Л. Гордеев

    2016-08-01

    Full Text Available Aim: The study was designed to investigate predictors of effective valve-sparing ascending aortic replacement in patients with Stanford type A aortic dissection combined with aortic insufficiency and to analyze efficacy and safety of this kind of surgery.Methods: From January 2010 to December 2015, 49 patients with Stanford type A aortic dissection combined with aortic insufficiency underwent ascending aortic replacement. All patients were divided into 3 groups: valve-sparing procedures (group 1, n = 11, combined aortic valve and supracoronary ascending aortic replacement (group 2, n = 12, and Bentall procedure (group 3, n = 26. We assessed the initial status of patients, incidence of complications and efficacy of valve-sparing ascending aortic replacement.Results: The hospital mortality rate was 8.2% (4/49 patients. The amount of surgical correction correlated with the initial diameter of the aorta at the level of the sinuses of Valsalva. During the hospital period, none of patients from group 1 developed aortic insufficiency exceeding Grade 2 and the vast majority of patients had trivial aortic regurgitation. The parameters of cardiopulmonary bypass, cross-clamp time and circulatory arrest time did not correlate with the initial size of the ascending aorta and aortic valve blood flow impairment, neither did they influence significantly the incidence and severity of neurological complications. The baseline size of the ascending aorta and degree of aortic regurgitation did not impact the course of the early hospital period.Conclusions: Supracoronary ascending aortic replacement combined with aortic valve repair in ascending aortic dissection and aortic regurgitation is effective and safe. The initial size of the ascending aorta and aortic arch do not influence immediate results. The diameter of the aorta at the level of the sinuses of Valsalva and the condition of aortic valve leaflets could be considered as the limiting factors. Further long

  8. The MIPAS balloon borne trace constitutent experiment

    Science.gov (United States)

    Oelhaf, H.; Vonclarmann, TH.; Fischer, H.; Friedl-Vallon, F.; Fritzsche, CHR.; Piesch, CHR.; Rabus, D.; Seefeldner, M.; Voelker, W.

    1994-01-01

    A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

  9. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    Pretolesi, F.; Derchi, L.E.; Redaelli, G.; Papagni, L.

    2001-01-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  10. An investigation of electrostatically deposited radionuclides on latex balloons

    International Nuclear Information System (INIS)

    Price, T.; Caly, A.

    2012-01-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  11. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  12. Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of severe aortic stenosis

    DEFF Research Database (Denmark)

    Siontis, George C M; Praz, Fabien; Pilgrim, Thomas

    2016-01-01

    AIMS: In view of the currently available evidence from randomized trials, we aimed to compare the collective safety and efficacy of transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) across the spectrum of risk and in important subgroups. METHODS AND RESULTS......: Trials comparing TAVI vs. SAVR were identified through Medline, Embase, and Cochrane databases. The primary outcome was death from any cause at 2 years. We performed random-effects meta-analyses to combine the available evidence and to evaluate the effect in different subgroups. This systematic review...... and meta-analysis is registered with PROSPERO (CRD42016037273). We identified four eligible trials including 3806 participants, who were randomly assigned to undergo TAVI (n = 1898) or SAVR (n = 1908). For the primary outcome of death from any cause, TAVI when compared with SAVR was associated...

  13. [Metabolic syndrome and aortic stiffness].

    Science.gov (United States)

    Simková, A; Bulas, J; Murín, J; Kozlíková, K; Janiga, I

    2010-09-01

    The metabolic syndrome (MS) is a cluster of risk factors that move the patient into higher level of risk category of cardiovascular disease and the probability of type 2 diabetes mellitus manifestation. Definition of MS is s based on the presence of selected risk factors as: abdominal obesity (lager waist circumpherence), atherogenic dyslipidemia (low value of HDL-cholesterol and increased level of triglycerides), increased fasting blood glucose (or type 2 DM diagnosis), higher blood pressure or antihypertensive therapy. In 2009 there were created harmonizing criteria for MS definition; the condition for assignment of MS is the presence of any 3 criteria of 5 mentioned above. The underlying disorder of MS is an insulin resistance or prediabetes. The patients with MS more frequently have subclinical (preclinical) target organ disease (TOD) which is the early sings of atherosclerosis. Increased aortic stiffness is one of the preclinical diseases and is defined by pathologically increased carotidofemoral pulse wave velocity in aorta (PWV Ao). With the aim to assess the influence of MS on aortic stiffness we examined the group of women with arterial hypertension and MS and compare them with the group of women without MS. The aortic stiffness was examined by Arteriograph--Tensiomed, the equipment working on the oscillometric principle in detection of pulsations of brachial artery. This method determines the global aortic stiffness based on the analysis of the shape of pulse curve of brachial artery. From the cohort of 49 pts 31 had MS, the subgroups did not differ in age or blood pressure level. The mean number of risk factors per person in MS was 3.7 comparing with 1.7 in those without MS. In the MS group there was more frequently abdominal obesity present (87% vs 44%), increased fasting blood glucose (81% vs 22%) and low HDL-cholesterol level. The pulse wave velocity in aorta, PWV Ao, was significantly higher in patients with MS (mean value 10,19 m/s vs 8,96 m

  14. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  15. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  16. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  17. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  18. JET pump limiter

    International Nuclear Information System (INIS)

    Sonnenberg, K.; Deksnis, E.; Shaw, R.; Reiter, D.

    1988-01-01

    JET plans to install two pump limiter modules which can be used for belt-limiter, inner-wall and X-point discharges and, also, for 1-2s as the main limiter. A design is presented which is compatible with two diagnostic systems, and which allows partial removal of the pump limiter to provide access for remote-handling operations. The high heat-flux components are initially cooled during a pulse. Heat is removed between discharges by radiation and pressure contacts to a water-cooled support structure. The pumping edge will be made of annealed pyrolytic graphite. Exhaust efficiency has been estimated, for a 1-d edge model, using a Monte-Carlo calculation of neutral gas transport. When the pump limiter is operated together with other wall components we expect an efficiency of ≅ 5% (2.5 x 10 21 part/s). As a main limiter the efficiency increases to about 10%. (author)

  19. Mechanical vaccum pumps

    CERN Document Server

    Chew, A D

    2007-01-01

    This presentation gives an overview of the technology of contemporary primary and secondary mechanical vacuum pumps. For reference a brief history of vacuum and a summary of important and basic vacuum concepts are first presented.

  20. Plant proton pumps

    DEFF Research Database (Denmark)

    Gaxiola, Roberto A.; Palmgren, Michael Gjedde; Schumacher, Karin

    2007-01-01

    to their constantly changing environments and at the same time maintain optimal metabolic conditions, the expression, activity and interplay of the pumps generating these H+ gradients have to be tightly regulated. In this review, we will highlight results on the regulation, localization and physiological roles...... of these H+- pumps, namely the plasma membrane H+-ATPase, the vacuolar H+-ATPase and the vacuolar H+-PPase. 2007 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved....

  1. Optically pumped laser systems

    International Nuclear Information System (INIS)

    DeMaria, A.J.; Mack, M.E.

    1975-01-01

    Laser systems which are pumped by an electric discharge formed in a gas are disclosed. The discharge is in the form of a vortex stabilized electric arc which is triggered with an auxiliary energy source. At high enough repetition rates residual ionization between successive pulses contributes to the pulse stabilization. The arc and the gain medium are positioned inside an optical pumping cavity where light from the arc is coupled directly into the gain medium

  2. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  3. [Unicuspid Aortic Valve Stenosis Combined with Aortic Coarctation;Report of a Case].

    Science.gov (United States)

    Kubota, Takehiro; Wakasa, Satoru; Shingu, Yasushige; Matsui, Yoshiro

    2016-06-01

    Unicuspid aortic valve in an adult is extremely rare. In addition, 90% of the patients with aortic coarctation are reported to die before the age 50. A 60-year-old woman was admitted to our hospital for further examination of exertional dyspnea which had begun one year before. She had been under medical treatment for hypertension since early thirties, and had been also diagnosed with moderate aortic stenosis at 50 years of age. She was at 1st diagnosed with aortic coarctation combined with bicuspid aortic valve stenosis. The aortic valve was then found unicuspid and was replaced under cardiopulmonary bypass with perfusion to both the ascending aorta and the femoral artery. Repair of aortic coarctation was performed 3 months later through left thoracotomy without extracorporeal circulation due to the rich collateral circulation. She had no postoperative complications, and hypertension as well as ankle-brachial index improved to the normal levels.

  4. Performance of Wind Pump Prototype

    African Journals Online (AJOL)

    Mulu

    Keywords: Wind pump, Windmill, Performance testing, Pump efficiency, Pump discharge,. Ethiopia. 1. INTRODUCTION. Energy demand .... Control/safety system. Mechanical control (by hand) .... important when irrigation is an issue. Daily water flow capacity is probably the best overall performance indicator of a wind pump.

  5. Performance of Wind Pump Prototype

    African Journals Online (AJOL)

    Mulu

    performance of the wind pump. One year wind speed data collected at 10 m height was extrapolated to the wind pump hub height using wind shear coefficient. The model assumed balanced rotor power and reciprocating pump, hence did not consider the effect of pump size. The theoretical model estimated the average ...

  6. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the

  7. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  8. Transcatheter Aortic Valve Replacement in Europe

    DEFF Research Database (Denmark)

    Mylotte, Darren; Osnabrugge, Ruben L J; Windecker, Stephan

    2013-01-01

    The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy.......The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy....

  9. Intermittent mechanical and clinical intravalvar regurgitation aortic ...

    African Journals Online (AJOL)

    due to intravalvar occlusion caused by thrombosis and/or tissue ingrowth or to periprosthetic regurgitation. .... position). A. The tilting disc of the prosthetic aortic valve is in the normal closed position during diastole. B. The disc is 'stuck' in the open position during diastole. Intermittent AR in patients with aortic prosthetic ...

  10. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  11. Thoracic aortic catastrophes : towards the endovascular solution

    NARCIS (Netherlands)

    Jonker, F.H.W.

    2010-01-01

    Descending thoracic aortic catastrophes include a variety of acute pathologies of the descending thoracic aorta, which are all associated with high morbidity and mortality rates, requiring immediate intervention. For this thesis, we explored the management and outcomes of several thoracic aortic

  12. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  13. OCT evaluation of directional atherectomy compared to balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Marmagkiolis, Konstantinos [Citizens Memorial Hospital Heart and Vascular Institute, Bolivar, MO (United States); Lendel, Vasili [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Cilingiroglu, Mehmet, E-mail: mcilingiroglu@yahoo.com [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Koc University, School of Medicine, Istanbul (Turkey)

    2015-09-15

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  14. Remote sensing and sensor testing via hot air balloons

    Energy Technology Data Exchange (ETDEWEB)

    Watson, S.M. [Univ. of Utah, Salt Lake City, UT (United States); Kroutil, R.T. [Army Edgewood Research, Development and Engineering Center, Aberdeen Proving Ground, MD (United States); Traynor, C.A. [DARPA High Performance Computing Applications, Arlington, VA (United States)] [and others

    1996-11-01

    Tethered and free-flying manned hot air balloons have been demonstrated as platforms for various remote sensing asks and sensor testing and atmospheric measurements. These platforms are inexpensive to operate, do not cause atmospheric disturbances as do higher speed platforms, and are extremely stable and free of vibrations inherent in aircraft structures. The equipment operated and tested on the balloons in connection with this project includes a prototype multispectral imaging spectrometer, high resolution CCD cameras, mid- and far-infrared cameras, a radiometer, FTIR spectrometers, video recording equipment and portable power generators carried beneath the balloon providing power to the equipment The experiments conducted on and from the balloon include chemical effluents characterization, atmospheric propagation through slant paths, obscurants imaging and scene reflectance. 7 refs.

  15. Development of Venus Balloon Seismology Missions Through Earth Analog Experiments

    Science.gov (United States)

    Krishnamoorthy, S.; Komjathy, A.; Cutts, J. A.; Pauken, M. T.; Garcia, R. F.; Mimoun, D.; Jackson, J. M.; Kedar, S.; Smrekar, S. E.; Hall, J. L.

    2017-11-01

    The study of a planet’s seismic activity is central to the understanding of its internal structure. We discuss advances made through Earth analog testing for performing remote seismology on Venus using balloons floated in the mid-atmosphere.

  16. Stabilization of ballooning modes with sheared toroidal rotation

    International Nuclear Information System (INIS)

    Miller, R.L.; Waelbroeck, F.L.; Hassam, A.B.; Waltz, R.E.

    1995-01-01

    Stabilization of magnetohydrodynamic ballooning modes by sheared toroidal rotation is demonstrated using a shifted circle equilibrium model. A generalized ballooning mode representation is used to eliminate the fast Alfven wave, and an initial value code solves the resulting equations. The s-α diagram (magnetic shear versus pressure gradient) of ballooning mode theory is extended to include rotational shear. In the ballooning representation, the modes shift periodically along the field line to the next point of unfavorable curvature. The shift frequency (dΩ/dq, where Ω is the angular toroidal velocity and q is the safety factor) is proportional to the rotation shear and inversely proportional to the magnetic shear. Stability improves with increasing shift frequency and direct stable access to the second stability regime occurs when this frequency is approximately one-quarter to one-half the Alfven frequency, ω A =V A /qR. copyright 1995 American Institute of Physics

  17. SMEX02 Balloon-borne Radiosonde Data, Iowa, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes radiosonde measurements of upper air temperature and pressure, relative humidity, and wind direction and speed during the balloons' ascent to...

  18. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    Science.gov (United States)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  19. A battery-operated pilot balloon time-signal generator

    Science.gov (United States)

    Ralph H. Moltzau

    1966-01-01

    Describes the design and construction of a 1-pound, battery-operated, time-signal transmitter, which is usable with portable radio or field telephone circuits for synchronizing multi-theodolite observation of pilot balloons.

  20. Balloon valvuloplasty for severe mitral valve stenosis in pregnancy

    African Journals Online (AJOL)

    . Commerford, B. Levetan. Balloon Valvuloplasties for severe mitral stenosis were performed on 11 ... 140 patients each year with cardiac disease - an incidence of 0.5%. ... Department of Medicine, Groote Schuur Hospital and University of.

  1. Ballooning stability analysis of JET H-mode discharges

    International Nuclear Information System (INIS)

    O'Brien, D.P.; Galvao, R.; Keilhacker, M.; Lazzaro, E.; Watkins, M.L.

    1989-01-01

    Previous studies of the stability of a large aspect ratio model equilibrium to ideal MHD ballooning modes have shown that across the bulk of the plasma there exist two marginally stable values of the pressure gradient parameter α. These define an unstable zone which separates the first (small α) stable region from the second (large α) stable region. Close to the separatrix, however, the first and second regions can coalesce when the surface averaged current density, Λ, exceeds a critical value. The plasma in this region is then stable to ballooning modes at all values of the pressure gradient. In this paper we extend these results to JET H-mode equilibria using a finite aspect ratio ballooning formalism, and assess the relevance of ideal ballooning stability in these discharges. In particular we analyse shot 15894 at time 56 sec. which is 1.3 s into the H-phase. (author) 4 refs., 4 figs

  2. 10 meter Sub-Orbital Large Balloon Reflector (LBR)

    Data.gov (United States)

    National Aeronautics and Space Administration — This is the lead NIAC Phase II proposal for “10 meter Sub-Orbital Large Balloon Reflector (LBR)” with Christopher K. Walker as PI. We propose to develop and...

  3. SMEX02 Balloon-borne Radiosonde Data, Iowa

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes radiosonde measurements of upper air temperature and pressure, relative humidity, and wind direction and speed during the balloons' ascent to...

  4. Ideal ballooning stability near an equilibrium magnetic island

    Energy Technology Data Exchange (ETDEWEB)

    Hegna, C.C.; Callen, J.D.

    1992-03-01

    The stability properties of ideal ballooning modes on toroidal flux surfaces near a quasistatic magnetic island is examined. On these surfaces, magnetic field-line trajectories tend to bunch on that part of the magnetic surface closet to the X-point of the magnetic island. Because of this preferential bunching, the stabilizing effect of field-line bending due to magnetic shear can be reduced. Eigenfunctions localized in helical angle near the X-point and in poloidal angle on the bad curvature side of the tokamak are more susceptible to ballooning instability than are modes in corresponding equilibria without the magnetic island. For a slowly growing island, a growing number of flux surfaces located near the separatrix become ballooning unstable. Secondary ballooning instabilities may play a part in the crash phase of sawteeth or macroscopic island dynamics.

  5. Open-heart surgery using a centrifugal pump: a case of hereditary spherocytosis.

    Science.gov (United States)

    Matsuzaki, Yuichi; Tomioka, Hideyuki; Saso, Masaki; Azuma, Takashi; Saito, Satoshi; Aomi, Shigeyuki; Yamazaki, Kenji

    2016-08-26

    Hereditary spherocytosis is a genetic, frequently familial hemolytic blood disease characterized by varying degrees of hemolytic anemia, splenomegaly, and jaundice. There are few reports on adult open-heart surgery for patients with hereditary spherocytosis. We report a rare case of an adult open-heart surgery associated with hereditary spherocytosis. A 63-year-old man was admitted for congestive heart failure due to bicuspid aortic valve, aortic valve regurgitation, and sinus of subaortic aneurysm. The family history, the microscopic findings of the blood smear, and the characteristic osmotic fragility confirmed the diagnosis of hereditary spherocytosis. Furthermore, splenectomy had not been undertaken preoperatively. The patient underwent a successful operation by means of a centrifugal pump. Haptoglobin was used during the cardiopulmonary bypass, and a biological valve was selected to prevent hemolysis. No significant hemolysis occurred intraoperatively or postoperatively. There are no previous reports of patients with hereditary spherocytosis, and bicuspid aortic valve. We have successfully performed an adult open-heart surgery using a centrifugal pump in an adult patient suffering from hereditary spherocytosis and bicuspid aortic valve.

  6. Properties of ballooning modes in the Heliotron configurations

    International Nuclear Information System (INIS)

    Nakajima, N.; Hudson, S.R.; Hegna, C.C.

    2005-01-01

    The stability of ballooning modes is influenced by the local and global magnetic shear and local and global magnetic curvature so significantly that it is fairly difficult to get those general properties in the three dimensional configurations with strong flexibility due to the external coil system. In the case of the planar axis heliotron configurations allowing a large Shafranov shift, like LHD, properties of the high-mode-number ballooning modes have been intensively investigated. It has been analytically shown that the local magnetic shear comes to disappear in the stellarator-like global magnetic shear region, as the Shafranov shift becomes large. Based on this mechanism and the characteristics of the local and global magnetic curvature, it is numerically shown that the destabilized ballooning modes have strong three-dimensional properties (both poloidal and toroidal mode couplings) in the Mercier stable region, and that those are fairly similar to ballooning modes in the axisymmetric system in the Mercier unstable region. As is well known, however, no quantization condition is applicable to the ballooning modes in the three-dimensional system without symmetry, and so the results of the high-mode-number ballooning modes in the covering space had to be confirmed in the real space. Such a confirmation has been done in the Mercier stable region and also in the Mercier unstable region by using three dimensional linearized ideal MHD stability code cas3d. Confirming the relation between high-mode-number ballooning analyses by the global mode analyses, the method of the equilibrium profile variations has been developed in the tree dimensional system, giving dt/dψ - dP/dψ stability diagram corresponding to the s - α diagram in tokamaks. This method of profile variation are very powerful to investigate the second stability of high-mode-number ballooning modes and has been more developed. Recently it has been applied to the plasma in the inward-shifted LHD

  7. Overview of the Scientific Balloon Activity in Sweden

    Science.gov (United States)

    Abrahamsson, Mattias; Kemi, Stig; Lockowandt, Christian; Andersson, Kent

    SSC, formerly known as Swedish Space Corporation, is a Swedish state-owned company working in several different space related fields, including scientific stratospheric balloon launches. Esrange Space Centre (Esrange in short) located in the north of Sweden is the launch facility of SSC, where both sounding rocket launches and stratospheric balloon launches are conducted. At Esrange there are also facilities for satellite communication, including one of the largest civilian satellite data reception stations in the world. Stratospheric balloons have been launched from Esrange since 1974, when the first flights were performed together with the French space agency CNES. These balloon flights have normally flown eastward either only over Sweden or into Finland. Some flights have also had permission to fly into Russia, as far as the Ural Mountains. Normal flight times are from 4 to 12 hours. These eastward flights are conducted during the winter months (September to May). Long duration flights have been flown from ESC since 2005, when NASA flew the BLAST payload from Sweden to north Canada. The prevailing westerly wind pattern is very advantageous for trans-Atlantic flights during summer (late May to late July). The long flight times are very beneficial for astronomical payloads, such as telescopes that need long observation times. In 2013 two such payloads were flown, the first called SUNRISE was a German/US solar telescope, and the other called PoGOLite with a Swedish gamma-ray telescope. In 14 days PoGOLite, which had permission to fly over Russia, made an almost complete circumpolar flight. Typical scientific balloon payload fields include atmospheric research, including research on ozone depletion, astronomical and cosmological research, and research in technical fields such as aerodynamics. University students from all over Europe are involved in flights from Esrange under a Swedish/German programme called BEXUS. Two stratospheric balloons are flown with student

  8. Na+/K+-pump modulates intercellular communication viainteraction with other membrane transporters in vascularsmooth muscle cells

    DEFF Research Database (Denmark)

    Matchkov, Vladimir; Hansen, Anne Kirstine; Nilsson, Holger

    Ouabain, an inhibitor of the Na+/K+-pump, has previously been shown to disturb intercellular communication. Here we test the hypothesis that the communication between vascular smooth muscle cells (SMCs) is regulated through an interaction between the Na+/K+-pump and the Na+/Ca2+-exchanger...... in restricted spaces near the plasma membrane. The intracellular Ca2+ concentration ([Ca2+]i) in individual SMCs was imaged simultaneously with isometric force in rat mesenteric small arteries. Paired cultured rat aortic smooth muscle cells (A7r5) were used as a model for electrical coupling of SMC by measuring...

  9. The Evaluation of Endoscopic Balloon Dilation Treatment for Benign

    Directory of Open Access Journals (Sweden)

    H. Ghofrani

    2008-04-01

    Full Text Available Background and ObjectiveBalloon dilatation of stricture is one of the new treatment methods for patients with Gastric Outlet Obstruction (GOO. Prevalence and underlying etiologies of GOO in various populations are different. The goal of the present study was to determine the effectiveness of endoscopic balloon dilatation and factors that could affect method advantage among patients with benign etiology for GOO. Methods Forty-five patients with symptoms of benign GOO were randomly selected. The mean age of patients was 43.7±18.1 years and 86.7% of them were men. Gastric outlet was delineated using double channel videoendoscopy. The severity of gastric pain was measured by VAS test immediately before and one month after balloon dilatation. Patients were followed after procedure weekly (for the first month and then monthly. Balloon dilatation was repeated for 27% patients during the follow up period.ResultsPatients were followed for 9.9±5.8 months. Furthermore, 71.1% were H. pylori positive. Positive response percent to endoscopic balloon dilatation was 80% and eight patients were took under surgical resection. Weight loss was seen frequently in the non-respondent group. The pain severity was significantly reduced in respondent subjects. No meaningful correlations were found between the response to balloon dilatation and positive H. pylori and cigarette smoking.ConclusionEndoscopic balloon dilatation is a safe and effective method for treating most of patients with benign gastric outlet obstruction and has favorable long-term outcome. Keywords: Endoscopy, Gastric Outlet Obstruction (GOO, Balloon Dilatation

  10. Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement: Incidence, Characteristics, and Treatment Outcomes.

    Science.gov (United States)

    Jose, John; Sulimov, Dmitriy S; El-Mawardy, Mohamed; Sato, Takao; Allali, Abdelhakim; Holy, Erik W; Becker, Björn; Landt, Martin; Kebernik, Julia; Schwarz, Bettina; Richardt, Gert; Abdel-Wahab, Mohamed

    2017-04-10

    The aim of this study was to determine the incidence, characteristics, and treatment outcomes of patients diagnosed with clinical transcatheter heart valve thrombosis. Limited data exists on clinical or manifest transcatheter heart valve thrombosis. Prior studies have focused on subclinical thrombosis. A retrospective analysis was conducted of prospectively collected data from a single-center registry that included 642 consecutive patients who underwent transcatheter aortic valve replacement between 2007 and 2015 (305 patients had self-expanding valves; balloon-expandable, n = 281; mechanically expanding, n = 56). Long-term oral anticoagulation (OAC) was indicated in 261 patients, while 377 patients received dual-antiplatelet therapy post-procedure. All patients underwent scheduled clinical and echocardiographic follow-up. The overall incidence of clinical valve thrombosis was 2.8% (n = 18). No patient on OAC developed thrombosis. Of the detected thrombosis cases, 13 patients had balloon-expandable, 3 had self-expanding, and 2 had mechanically expanding valves. Thrombosis occurred significantly more often with balloon-expandable valves (odds ratio: 3.45; 95% confidence interval: 1.22 to 9.81; p = 0.01) and following valve-in-valve procedures (odds ratio: 5.93; 95% confidence interval: 2.01 to 17.51; p = 0.005). Median time to diagnosis of valve thrombosis was 181 days. The median N-terminal pro-brain natriuretic peptide level was 1,318 pg/ml (interquartile range: 606 to 1,676 pg/ml). The mean transvalvular gradient and valve area were 34 ± 14 mm Hg and 1.0 ± 0.46 cm 2 , respectively. Computed tomography showed hypoattenuating areas with reduced leaflet motion. Initiation of OAC resulted in significant reduction of transvalvular gradient and clinical improvement. No deaths were related to valve thrombosis. Clinical transcatheter heart valve thrombosis is more common than previously considered, characterized by imaging abnormalities and increased gradients

  11. Ballooning Stability of the Compact Quasiaxially Symmetric Stellarator

    International Nuclear Information System (INIS)

    Redi, M.H.; Canik, J.; Dewar, R.L.; Johnson, J.L.; Klasky, S.; Cooper, W.A.; Kerbichler, W.

    2001-01-01

    The magnetohydrodynamic (MHD) ballooning stability of a compact, quasiaxially symmetric stellarator (QAS), expected to achieve good stability and particle confinement is examined with a method that can lead to estimates of global stability. Making use of fully 3D, ideal-MHD stability codes, the QAS beta is predicted to be limited above 4% by ballooning and high-n kink modes. Here MHD stability is analyzed through the calculation and examination of the ballooning mode eigenvalue isosurfaces in the 3-space [s, alpha, theta(subscript ''k'')]; s is the edge normalized toroidal flux, alpha is the field line variable, and theta(subscript ''k'') is the perpendicular wave vector or ballooning parameter. Broken symmetry, i.e., deviations from axisymmetry, in the stellarator magnetic field geometry causes localization of the ballooning mode eigenfunction, with new types of nonsymmetric, eigenvalue isosurfaces in both the stable and unstable spectrum. The isosurfaces around the most unstable points i n parameter space (well above marginal) are topologically spherical. In such cases, attempts to use ray tracing to construct global ballooning modes lead to a k-space runaway. Introduction of a reflecting cutoff in k(perpendicular) to model numerical truncation or finite Larmor radius (FLR) yields chaotic ray paths ergodically filling the allowed phase space, indicating that the global spectrum must be described using the language of quantum chaos theory. However, the isosurface for marginal stability in the cases studied are found to have a more complex topology, making estimation of FLR stabilization more difficult

  12. [Modern aortic surgery in Marfan syndrome--2011].

    Science.gov (United States)

    Kallenbach, K; Schwill, S; Karck, M

    2011-09-01

    Marfan syndrome is a hereditary disease with a prevalence of 2-3 in 10,000 births, leading to a fibrillin connective tissue disorder with manifestations in the skeleton, eye, skin, dura mater and in particular the cardiovascular system. Since other syndromes demonstrate similar vascular manifestations, but therapy may differ significantly, diagnosis should be established using the revised Ghent nosology in combination with genotypic analysis in specialized Marfan centres. The formation of aortic root aneurysms with the subsequent risk of acute aortic dissection type A (AADA) or aortic rupture limits life expectancy in patients with Marfan syndrome. Therefore, prophylactic replacement of the aortic root needs to be performed before the catastrophic event of AADA can occur. The goal of surgery is the complete resection of pathological aortic tissue. This can be achieved with excellent results by using a (mechanically) valved conduit that replaces both the aortic valve and the aortic root (Bentall operation). However, the need for lifelong anticoagulation with Coumadin can be avoided using the aortic valve sparing reimplantation technique according to David. The long-term durability of the reconstructed valve is favourable, and further technical improvements may improve longevity. Although results of prospective randomised long-term studies comparing surgical techniques are lacking, the David operation has become the surgical method of choice for aortic root aneurysms, not only at the Heidelberg Marfan Centre. Replacement of the aneurysmal dilated aortic arch is performed under moderate hypothermic circulatory arrest combined with antegrade cerebral perfusion using a heart-lung machine, which we also use in thoracic or thoracoabdominal aneurysms. Close post-operative follow-up in a Marfan centre is pivotal for the early detection of pathological changes on the diseased aorta.

  13. Imaging techniques in aortic valve and root surgery

    NARCIS (Netherlands)

    Regeer, M.V.

    2017-01-01

    Aortic valve sparing surgery for aortic regurgitation and/or aortopathy serves as an alternative to aortic valve and root replacement. One of the advantages of aortic valve sparing surgery over conventional replacement is that there is no need for life-long anticoagulation, which is particularly

  14. Leaking mycotic abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Sing, T.M.Y.; Young, N.; O'Rourke, I.C.; Tomlinson, P.

    1994-01-01

    A case of leaking mycotic abdominal aortic aneurysm is reported, with a brief review of the literature. A 58 year old female presented with shoulder and abdominal pain associated with diarrhea, vomiting and fever with leucocytosis. Computed tomography of the abdomen showed pooling of contrast in the retroperitoneum anterior to a non-dilated abdominal aorta. There was considerable retroperitoneal blood accumulating in a mass-like lesion in the right lower abdomen and pelvis obstructing the right renal collecting system. Laparotomy revealed a 4 cm diameter saccular aneurysm of the abdominal aorta, with a 1 cm diameter neck. Culture of the thrombus grew Streptococcus pyogens. 11 refs., 2 figs

  15. FELINE AORTIC THROMBOEMBOLISM: CASE REPORT

    OpenAIRE

    Figueroa A., Lizbeth; Facultad de Medicina Veterinaria, Universidad Nacional Mayor de San Marcos, Lima, Perú.; Paz M., Ricardo; Facultad de Medicina Veterinaria, Universidad Nacional Mayor de San Marcos, Lima, Perú.; Díaz C., Diego; Facultad de Medicina Veterinaria, Universidad Nacional Mayor de San Marcos, Lima, Perú.; Dávila F., Roberto; Facultad de Medicina Veterinaria, Universidad Nacional Mayor de San Marcos, Lima, Perú.

    2014-01-01

    Se presenta el caso de un felino Siamés de 13 años con tromboembolismo aórtico. Esta es una complicación asociada a una cardiomiopatía hipertrófica (CMH), enfermedad cardiaca más común del gato y que se caracteriza por la hipertrofia concéntrica ventricular izquierda. A case of a 13 year old Siamese cat whit feline aortic thromboembolism is presented. This is a devastating complication associated to hypertrophic cardiomyopathy (HCM), one of the most common heart disease in cats characteriz...

  16. Subacute Aortic Regurgitation as a Rare Presentation of Latrogenic Aortic Valve Leaflet Perforation

    Directory of Open Access Journals (Sweden)

    Hassan Teimouri

    2009-12-01

    Full Text Available There is a paucity of literature regarding iatrogenic aortic valve perforation after cardiac operation is performed in the vicinity of the aortic valve. This report describes the clinical, echocardiographic, and angiocardiographic recognition of iatrogenic aortic valve perforation in a patient who had previously under gone membranous ventricular septal defect and pulmonary stenosis. Five days after the operation, the patient showed subacute signs and symptoms of congestive heart failure in surgical ward. Echocardiographic examination revealed free aortic regurgitation. The patient was scheduled for operation, which was performed using cardiopulmonary bypass and cardioplegic arrest. During the operation, exploration of the aortic root revealed tearing non-coronary aortic cusp at the level of the aortic ring and slightly dilated the left sinus. Despite close examination, no suture could be identified. It was reasoned that the tension created by the dacron patch pulled on the adjacent tissue and caused the separation of the non-coronary cusp from its ring and the patient was treated by aortic valve replacement with prosthetic aortic valve. We did not have the facility to use transesophaseal echocardiography for the examination of aortic valve repair and the poor condition of the patient did not permit us to repair the valve. Precise preoperative diagnosis of this lesion allows optimal surgical planning and treatment.

  17. Endoluminal Treatment of Ruptured Abdominal Aortic Aneurysm with Small Intestinal Submucosa Sandwich Endografts: A Pilot Study in Sheep

    International Nuclear Information System (INIS)

    Yamada, Katsuyuki; Pavcnik, Dusan; Uchida, Barry T.; Timmermans, Hans A.; Corless, Christopher L.; Yin, Qiang; Yamakado, Koichiro; Wha Park, Joong; Roesch, Josef; Keller, Frederick S.; Sato, Morio; Yamada, Ryusaku

    2001-01-01

    Purpose: To evaluate efficacy of small intestinal submucosa (SIS) Sandwich endografts for the treatment of acute rupture of abdominal aortic aneurysms (AAA) and to explore the short-term reaction of the aorta to this material.Methods: In eight adult sheep, an infrarenal AAA was created transluminally by dilation of a short Palmaz stent. In six sheep, the aneurysm was then ruptured by overdilation of the stent with a large angioplasty balloon. Two sheep with AAAs that were not ruptured served as controls. A SIS Sandwich endograft, consisting of a Z stent frame with 5 bodies and covered inside and out with SIS, was used to exclude the ruptured and non-ruptured AAAs. Follow-up aortography was done immediately after the procedure and before sacrifice at 4, 8, or 12 weeks. Autopsy and histologic studies followed.Results: Endograft placement was successful in all eight sheep. Both ruptured and non-ruptured AAAs were successfully excluded. Three animals with AAA rupture developed hind leg paralysis due to compromise of the arterial supply to the lower spinal cord and were sacrificed 1 day after the procedure. In five animals, three with rupture and two controls, follow-up aortograms revealed no aortic stenoses and no perigraft leaks. Gross and histologic studies revealed incorporation of the endografts into the aortic wall with replacement of SIS by dense neointima that was completely endothelialized in areas where the endograft was in direct contact with the aortic wall. In central portions of the endograft, in contact with the thrombosed aneurysm, endothelialization was incomplete even at 12 weeks.Conclusion: The SIS Sandwich endografts effectively excluded simple AAAs and ruptured AAAs. They were rapidly incorporated into the aortic wall. A detailed long-term study is warranted

  18. Aortic root surgery in Marfan syndrome: Comparison of aortic valve-sparing reimplantation versus composite grafting.

    Science.gov (United States)

    Karck, Matthias; Kallenbach, Klaus; Hagl, Christian; Rhein, Christine; Leyh, Rainer; Haverich, Axel

    2004-02-01

    The objective of this study was to compare the results of aortic valve-sparing reimplantation and aortic root replacement with mechanical valve conduits in patients with Marfan syndrome undergoing operation for aortic root aneurysms. Patients and methods Between March 1979 and April 2002, 119 patients with clinical evidence of Marfan syndrome underwent composite graft replacement with mechanical valve conduits (n = 74) or aortic valve-sparing reimplantation according to David (n = 45). The underlying causes were aortic dissection type A (43 patients) and aneurysms (76 patients). Patients undergoing aortic valve reimplantation were younger compared with patients undergoing composite grafting (28 vs 35 years, P =.002) and had longer intraoperative aortic crossclamp times (125 vs 78 minutes, P valve reimplantation (P =.15). Mean follow-up was 30 months for patients undergoing aortic valve reimplantation and 114 months for patients undergoing composite grafting. Freedom from reoperation and death after 5 years postoperatively was 92% and 89% in patients undergoing composite grafting and 84% and 96% in patients undergoing aortic valve reimplantation (P =.31; P =.54), respectively. Thromboembolic complications or late postoperative bleeding occurred in 17 patients undergoing composite grafting, and an early postoperative event occurred in 1 patient undergoing aortic valve reimplantation. The results of aortic valve reimplantation and composite grafting of the aortic valve and ascending aorta with mechanical valve conduits are similar with regard to early and mid-term postoperative mortality and to the incidence of late reoperations in patients with Marfan syndrome. The low risk of thromboembolic or bleeding complications favors aortic valve reimplantation in these patients.

  19. Repetitive complications after prosthetic graft for inflammatory aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Yoshihiro Takeda

    2013-11-01

    Full Text Available The presence of retroperitoneal fibrosis after an aortic graft replacement is a marker of poor prognosis following aortic graft replacement. Herein we report the case of a 39-year-old man with retroperitoneal fibrosis that had been causing ureteral obstruction. The man had undergone repeated aortic graft replacement due to bacteremia and aortic graft–small intestinal fistula that occurred 4 years after initial aortic grafting for an inflammatory aortic aneurysm. The patient was discharged after 4 weeks of intravenous antibiotic therapy following the latest aortic graft replacement.

  20. Development of a numerical pump testing framework.

    Science.gov (United States)

    Kaufmann, Tim A S; Gregory, Shaun D; Büsen, Martin R; Tansley, Geoff D; Steinseifer, Ulrich

    2014-09-01

    It has been shown that left ventricular assist devices (LVADs) increase the survival rate in end-stage heart failure patients. However, there is an ongoing demand for an increased quality of life, fewer adverse events, and more physiological devices. These challenges necessitate new approaches during the design process. In this study, computational fluid dynamics (CFD), lumped parameter (LP) modeling, mock circulatory loops (MCLs), and particle image velocimetry (PIV) are combined to develop a numerical Pump Testing Framework (nPTF) capable of analyzing local flow patterns and the systemic response of LVADs. The nPTF was created by connecting a CFD model of the aortic arch, including an LVAD outflow graft to an LP model of the circulatory system. Based on the same geometry, a three-dimensional silicone model was crafted using rapid prototyping and connected to an MCL. PIV studies of this setup were performed to validate the local flow fields (PIV) and the systemic response (MCL) of the nPTF. After validation, different outflow graft positions were compared using the nPTF. Both the numerical and the experimental setup were able to generate physiological responses by adjusting resistances and systemic compliance, with mean aortic pressures of 72.2-132.6 mm Hg for rotational speeds of 2200-3050 rpm. During LVAD support, an average flow to the distal branches (cerebral and subclavian) of 24% was found in the experiments and the nPTF. The flow fields from PIV and CFD were in good agreement. Numerical and experimental tools were combined to develop and validate the nPTF, which can be used to analyze local flow fields and the systemic response of LVADs during the design process. This allows analysis of physiological control parameters at early development stages and may, therefore, help to improve patient outcomes. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  1. Wet motor geroter fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Wiernicki, M.V.

    1987-05-05

    This patent describes a wet motor gerotor fuel pump for pumping fuel from a fuel source to an internal combustion which consists of: gerotor pump means comprising an inner pump gear, an outer pump gear, and second tang means located on one of the inner and outer pump gears. The second tang means further extends in a second radial direction radially offset from the first radial direction and forms a driving connection with the first tang means such that the fuel pump pumps fuel from the fuel source into the narrow conduit inlet chamber, through the gerotor pump means past the electric motor means into the outlet housing means substantially along the flow axis to the internal combustion engine.

  2. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    BACKGROUND: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR...

  3. Controlled weather balloon ascents and descents for atmospheric research and climate monitoring

    Science.gov (United States)

    Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F.; Hall, Emrys G.; Jordan, Allen F.

    2016-03-01

    In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth's surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.

  4. Miniature Lightweight Ion Pump

    Science.gov (United States)

    Sinha, Mahadeva P.

    2010-01-01

    This design offers a larger surface area for pumping of active gases and reduces the mass of the pump by eliminating the additional vacuum enclosure. There are three main components to this ion pump: the cathode and anode pumping elements assembly, the vacuum enclosure (made completely of titanium and used as the cathode and maintained at ground potential) containing the assembly, and the external magnet. These components are generally put in a noble diode (or differential) configuration of the ion pump technology. In the present state of the art, there are two cathodes, one made of titanium and the other of tantalum. The anodes are made up of an array of stainless steel cylinders positioned between the two cathodes. All the elements of the pump are in a vacuum enclosure. After the reduction of pressure in this enclosure to a few microns, a voltage is applied between the cathode and the anode elements. Electrons generated by the ionization are accelerated toward the anodes that are confined in the anode space by the axial magnetic field. For the generation of the axial field along the anode elements, the magnet is designed in a C-configuration and is fabricated from rare earth magnetic materials (Nd-B-Fe or Sm-Co) possessing high energy product values, and the yoke is fabricated from the high permeability material (Hiperco-50A composed of Fe-Co-V). The electrons in this region collide with the gas molecules and generate their positive ions. These ions are accelerated into the cathode and eject cathode material (Ti). The neutral atoms deposit on the anode surfaces. Because of the chemical activity of Ti, the atoms combine with chemically active gas molecules (e.g. N2, O2, etc.) and remove them. New layers of Ti are continually deposited, and the pumping of active gases is thus accomplished. Pumping of the inert gases is accomplished by their burial several atomic layers deep into the cathode. However, they tend to re-emit if the entrapping lattice atoms are

  5. Balloon catheter dilatation of benign urethral strictures

    International Nuclear Information System (INIS)

    Perini, L.; Cavallo, A.; Perin, B.; Bighi, G.

    1988-01-01

    The authors report their experience of benign urethral stricture dilatation by balloon catheter in 11 male patients. Ten posterior and 2 anterior urethral strictures were treated; in 1 patients several narrowings coexisted at various levels. Etiology was inflammatory in 4 cases, iatrogen in 3, post-traumatic in 2, and equivocal in 2. The patients were studied both before and soon after dilatation by means of retrograde and voiding cystourethrogram and uroflowgraphy; the follow-up (2-14 months) was performed by urodynamic alone. In all cases, dilatation was followed by the restoration of urethral gauge, together with prompt functional improvement of urodynamic parameters. The latter result subsisted in time in 9 patients. In 2 cases recurrences were observed demonstrated at once by clinics and urodynamics. Both lesions were successfully re-treated. Neither early not late complication occurred. In spite of the limited material, the valuable results obtained, together with the absence of complications, the peculiar morphology of recurrences, and the chance of repeating it make the procedure advisable as a valid alternative to conventional techniques for these pathologies

  6. Retrograde prostatic urethroplasty with a balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Hulbert, J.; Letourneau, J.G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1987-01-01

    Twenty-five patients with prostatism and documented BPH who were candidates for transurethral resection of the prostate were dilated for 10 minutes with 25-mm urethroplasty balloons using a retrograde transurethral approach. The procedure was performed under local anesthesia using 2% viscous lidocaine on an outpatient basis. A mild discomfort was experienced by all patients with a moderate urgency sensation. Mild transient hematuria was present in all, which cleared in 4 to 6 hours. Dysuria usually lasted for 72 hours. Significant improvement has been seen in the relief of symptoms in patients without middle-lobe hypertrophy as documented by uroflow studies, voiding cystourethrograms, and retrograde urethrograms. In patients with middle-lobe hypertrophy, moderate improvement in uroflow studies was observed, which correlated well with symptomatic improvement. Rectal US and MR studies have shown no evidence of intraprostatic or periprostatic abnormalities. No complications have been encountered so far. The longest current follow-up is 20 months, with a mean of 10 months

  7. Mechanism of prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Maynar, M.; Hulbert, J.

    1988-01-01

    A series of 60 patients have undergone prostatic urethroplasty with balloon catheters at our institution. The follow-up of these patients has ranged from more than 3 years to not less than 6 months. The preliminary results have been excellent, with a success rate of 75% in patients with predominant lateral lobe hypertrophy. This success rate drops to 25% in patients with predominant middle lobe hypertrophy. In previous communications the authors have proposed that the mechanism of prostatic urethral relief of obstruction is due to stretching of the prostatic capsule, tissue compression, and possible subsequent atrophy, as suggested by findings of transrectal US, MR imaging, voiding and retrograde urethrography, and urinary flow studies. Recent clinical information that has led to further animal research has shown that in addition to the previously supposed mechanism of action, separation of the prostatic lobes occurs by splitting of the anterior and posterior commissures of the prostatic gland tissue. This separation of the prostatic lobes is therefore the goal of the procedure. As more experience is gained, the already high success rate can probably be improved

  8. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, I-Ming [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China); Chen, Po-Lin; Huang, Chun-Yang [National Yang Ming University, Department of Medicine, School of Medicine (China); Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che, E-mail: ccshih@vghtpe.gov.tw [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China)

    2017-05-15

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  9. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  10. Reactor coolant pump flywheel

    Science.gov (United States)

    Finegan, John Raymond; Kreke, Francis Joseph; Casamassa, John Joseph

    2013-11-26

    A flywheel for a pump, and in particular a flywheel having a number of high density segments for use in a nuclear reactor coolant pump. The flywheel includes an inner member and an outer member. A number of high density segments are provided between the inner and outer members. The high density segments may be formed from a tungsten based alloy. A preselected gap is provided between each of the number of high density segments. The gap accommodates thermal expansion of each of the number of segments and resists the hoop stress effect/keystoning of the segments.

  11. Velocity pump reaction turbine

    Science.gov (United States)

    House, P.A.

    An expanding hydraulic/two-phase velocity pump reaction turbine including a dual concentric rotor configuration with an inter-rotor annular flow channel in which the inner rotor is mechanically driven by the outer rotor. In another embodiment, the inner rotor is immobilized and provided with gas recovery ports on its outer surface by means of which gas in solution may be recovered. This velocity pump reaction turbine configuration is capable of potential energy conversion efficiencies of up to 70%, and is particularly suited for geothermal applications.

  12. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  13. Vacuum pumping concepts for ETF

    International Nuclear Information System (INIS)

    Homeyer, W.G.

    1980-09-01

    The Engineering Test Facility (ETF) poses unique vacuum pumping requirements due to its large size and long burn characteristics. These requirements include torus vacuum pumping initially and between burns and pumping of neutralized gas from divertor collector chambers. It was found that the requirements could be met by compound cryopumps in which molecular sieve 5A is used as the cryosorbent. The pumps, ducts, and vacuum valves required are large but fit with other ETF components and do not require major advances in vacuum pumping technology. Several additional design, analytical, and experimental studies were identified as needed to optimize designs and provide better design definition for the ETF vacuum pumping systems

  14. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  15. Ascending aortic injuries following blunt trauma.

    Science.gov (United States)

    Sun, Xiumei; Hong, Jenny; Lowery, Robert; Goldstein, Steven; Wang, Zuyue; Lindsay, Joseph; Hill, Peter C; Corso, Paul J

    2013-11-01

    The diagnosis and the management of traumatic thoracic aortic injuries have undergone significant changes due to new technology and improved prehospital care. Most of the discussions have focused on descending aortic injuries. In this review, we discuss the recent management of ascending aortic injuries. We found 5 cohort studies on traumatic aortic injuries and 11 case reports describing ascending aortic injuries between 1998 to the present through Medline research. Among case reports, 78.9% of cases were caused by motor vehicle accidents (MVA). 42.1% of patients underwent emergent open repair and the operative mortality was 12.5%. 36.8% underwent delayed repair. Associated injuries occurred in 84.2% of patients. Aortic valve injury was concurrent in 26.3% of patients. The incidence of ascending aortic injury ranged 1.9-20% in cohort studies. Traumatic injuries to the ascending aorta are relatively uncommon among survivors following blunt trauma. Aortography has been replaced by computed tomography and echocardiography as a diagnostic tool. Open repair, either emergent or delayed, remains the treatment of choice. © 2013 Wiley Periodicals, Inc.

  16. The bicuspid aortic valve and related disorders

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    Full Text Available Bicuspid aortic valve (BAV is the most common congenital cardiac malformation, affecting 1-2% of the population, with strong male predominance. Individuals may have a normally functioning BAV, and may be unaware of its presence and the potential risk of complications. However, they may easily develop aortic valve disorders: either stenotic or regurgitant, or both. Today, BAV is recognized as a syndrome incorporating aortic valve disorders and aortic wall abnormalities, including aortic dilation, dissection or rupture. Congenital or hereditary diseases such as ventricular septal defect, patent ductus arteriosus, coarctation of the aorta, Turner's syndrome, Marfan's syndrome etc., may frequently be associated with BAV. Infective endocarditis and occasionally thrombus formation may develop during the lives of BAV patients. Elevated cholesterol or C-reactive protein may be seen in laboratory findings of these patients. Beta-blockers and statins are the possibilities for medical treatment, and aortic valve repair/replacement and ascending aorta replacement are indicated for patients with a severely diseased aortic valve and aorta. Rigorous follow-up throughout life is mandatory after BAV has been diagnosed. The aim of the present article was to describe the implications of BAV and its associated disorders, and to discuss diagnostic and treatment strategies.

  17. Selective Heart, Brain and Body Perfusion in Open Aortic Arch Replacement.

    Science.gov (United States)

    Maier, Sven; Kari, Fabian; Rylski, Bartosz; Siepe, Matthias; Benk, Christoph; Beyersdorf, Friedhelm

    2016-09-01

    Open aortic arch replacement is a complex and challenging procedure, especially in post dissection aneurysms and in redo procedures after previous surgery of the ascending aorta or aortic root. We report our experience with the simultaneous selective perfusion of heart, brain, and remaining body to ensure optimal perfusion and to minimize perfusion-related risks during these procedures. We used a specially configured heart-lung machine with a centrifugal pump as arterial pump and an additional roller pump for the selective cerebral perfusion. Initial arterial cannulation is achieved via femoral artery or right axillary artery. After lower body circulatory arrest and selective antegrade cerebral perfusion for the distal arch anastomosis, we started selective lower body perfusion simultaneously to the selective antegrade cerebral perfusion and heart perfusion. Eighteen patients were successfully treated with this perfusion strategy from October 2012 to November 2015. No complications related to the heart-lung machine and the cannulation occurred during the procedures. Mean cardiopulmonary bypass time was 239 ± 33 minutes, the simultaneous selective perfusion of brain, heart, and remaining body lasted 55 ± 23 minutes. One patient suffered temporary neurological deficit that resolved completely during intensive care unit stay. No patient experienced a permanent neurological deficit or end-organ dysfunction. These high-risk procedures require a concept with a special setup of the heart-lung machine. Our perfusion strategy for aortic arch replacement ensures a selective perfusion of heart, brain, and lower body during this complex procedure and we observed excellent outcomes in this small series. This perfusion strategy is also applicable for redo procedures.

  18. Evidence suggests rigid aortic grafts increase systolic blood pressure: results of a preliminary study.

    Science.gov (United States)

    O'Brien, T; Morris, L; McGloughlin, T

    2008-01-01

    Abdominal aortic aneurysm (AAA) is a serious complication of the aorta and is treated using vascular bypass grafts. Two main classes of graft are available to treat AAA; grafts implanted by open surgery and stent-grafts implanted using minimally invasive endovascular techniques. Both classes of graft consist of an aortic section which bifurcates into two iliac sections. It has been hypothesized that implantation of aortic grafts and stent-grafts serve to significantly increase abdominal aortic pressures. In this study, an open-loop computer-controlled pumping system was built to produce physiologically realistic pressure and flow-rates. Models of a compliant abdominal aortic aneurysm, a compliant walled graft and a tapered graft were manufactured using an injection moulding technique and fused deposition modelling was used to create a rigid walled graft. A specific transient flow-rate waveform was then applied at the inlet of each model and the resulting pressure waveforms 30 mm upstream from the bifurcation was recorded. Peak pressure measurements were recorded over the course of the pulse for each model. The compliant aneurysm model was found to have a systolic pressure of 107 mmHg while the complaint graft model was 153 mmHg. The rigid graft model had a peak systolic pressure of 199 mmHg. In the tapered graft, the peak pressure dropped to 142 mmHg. The data suggests that implanting a graft model in place of an aneurysm model in an in vitro flow circuit can increase the pressures recorded upstream from the iliac bifurcation and that tapered grafts may alleviate this problem.

  19. PUMP ARRANGEMENT COMPRISING A SAFETY VALVE ARRANGEMENT

    OpenAIRE

    Richter, Martin; Wackerle, Martin

    2014-01-01

    A pump arrangement comprises a microfluidic pump (20) having a pump inlet (22) and a pump outlet (24), which is configured to pump a fluid from the pump inlet to the pump outlet, wherein the pump inlet (22) and an inlet (46) of the pump arrangement are fluidically connected. The pump arrangement further comprises a safety valve arrangement having first safety valve (40), the first safety valve (40) being arranged between the pump outlet (24) and an outlet (48) of the pump arrangement and comp...

  20. Pump arrangement Comprising a Savety Valve

    OpenAIRE

    Richter, M.; Kruckow, J.

    2009-01-01

    A pump arrangement comprises a pump (20) having a pump inlet (22) and a pump outlet (24), which are designed to pump a fluid from the pump inlet to the pump outlet, and it further comprises a safety valve (40), which is disposed between the pump outlet (24) and an outlet (48) of the pump arrangement and comprises a valve set (42) and a valve cover (44). The valve seat, the pump outlet, and the pump inlet are structured in a first surface of a first single-piece part (14) of the pump arrangeme...