Comparative efficacy of antigen and antibody detection tests for human trichinellosis
International Nuclear Information System (INIS)
Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.
1989-01-01
Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation
Antigen spot test (AST): a highly sensitive assay for the detection of antibodies
Energy Technology Data Exchange (ETDEWEB)
Herbrink, P; van Bussel, F J; Warnaar, S O [Rijksuniversiteit Leiden (Netherlands)
1982-02-12
A method is described for detection of antibodies by means of nitrocellulose or diazobenzyloxymethyl (DBM) paper on which various antigens have been spotted. The sensitivity of this antigen spot test (AST) is comparable with that of RIA and ELISA. The method requires only nanogram amounts of antigen. Since a variety of antigens can be spotted on a single piece of nitrocellulose or DBM paper, this antigen spot test is especially useful for specificity controls on antibodies.
International Nuclear Information System (INIS)
Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Aguilar Rubido; Julio C
2009-01-01
The disappearance of the e antigen and the appearance of anti-e antigen antibodies are two biomarkers that indicate favorable prognosis in Hepatitis B. In this study the Advanced QualityTM immunochromatographic test for detecting those biomarkers was compared to the Vidas semi-quantitative ELISA test. Our hypothesis was that it is possible to use these biomarkers measured in a rapid and simple Advanced QualityTM immunochromatographic test for evaluating the therapeutic response in clinical trials with chronic hepatitis B patients. The two methods were done following the manufacturer's instructions. The sera were taken from 69 patients with chronic hepatitis B of the clinical trial of the CIGB 440 therapeutic candidate. The immunochromatographic test and ELISA for detecting e antigen and anti-e antigen antibodies presented from substantial to almost perfect agreement in the evaluation of the sera of chronic Hepatitis B patients in a clinical trial. The immunochromatographic test for detecting e antigen had a low positive average agreement and a high negative average agreement compared to the ELISA. Nevertheless, the immunochromatographic test for detecting anti-e antigen antibodies had a high negative and positive average agreement in comparison to the ELISA. The immunochromagraphic test for the e antigen had a lower positive average agreement compared to the ELISA and some patients infected with Hepatitis B virus could not be detected by the former assay. The immunochromatographic test for anti-e antigen antibodies showed a similar performance to that of ELISA and could therefore be used in clinical trials for chronic Hepatitis B in health institutions without the need of a highly qualified lab technician. (author)
Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.
Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz
The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,
Directory of Open Access Journals (Sweden)
Flávio da Silva Mesquita
Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.
KAtex antigen-detection test as a diagnostic tool for latent visceral ...
African Journals Online (AJOL)
SERVER
2008-04-03
Apr 3, 2008 ... Urine samples were tested by kAtex kit to detect VL antigen. All sera .... IFA, and ELISA-IgG and IgM) to finding of agreement and validity and reliability .... Animal inoculation is not usually employed as a diag- nostic test, since ...
Histoplasma Urinary Antigen Testing Obviates the Need for Coincident Serum Antigen Testing.
Libert, Diane; Procop, Gary W; Ansari, Mohammad Q
2018-03-07
Serum and urine antigen (SAg, UAg) detection are common tests for Histoplasma capsulatum. UAg detection is more widely used and reportedly has a higher sensitivity. We investigated whether SAg detection contributes meaningfully to the initial evaluation of patients with suspected histoplasmosis. We reviewed 20,285 UAg and 1,426 SAg tests ordered from 1997 to 2016 and analyzed paired UAg and SAg tests completed on the same patient within 1 week. We determined the positivity rate for each test. Of 601 paired specimens, 542 were concurrent negatives and 48 were concurrent positives (98% agreement). Medical records were available for eight of 11 pairs with discrepant results. UAg was falsely positive in six instances, truly positive once, and falsely negative once. These findings support using a single antigen detection test, rather than both UAg and SAg, as an initial screen for suspected histoplasmosis. This aligns with the current practice of most physicians.
Cardoso, Débora Morais; Gilio, Alfredo Elias; Hsin, Shieh Huei; Machado, Beatriz Marcondes; de Paulis, Milena; Lotufo, João Paulo B; Martinez, Marina Baquerizo; Grisi, Sandra Josefina E
2013-01-01
To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.
International Nuclear Information System (INIS)
Karol, M.H.; Alarie, Y.C.
1980-01-01
A test antigen for detecting antibodies to a diisocyanate comprises the reaction product of a protein and a monoisocyanate derived from the same radical as the diisocyanate. The diisocyanates most usually encountered and therefore calling for antibody detection are those of toluene, hexamethylene, methylene, isophorone and naphthylene. The preferred protein is human serum albumin. (author)
Detection of antigens of allergic diseases in children by radioallergosorbent test (RAST), 1
International Nuclear Information System (INIS)
Hirooka, Junko
1977-01-01
Detection of antigens mainly by RAST, measurement of immunoglobulin, and investigation of clinical history were performed on children with intractable bronchial asthma. The results were compared with those in cases of mild or moderate degree, and they were discussed. The obtained results were as follows: 1) Cases, of which the occurrence age of disease was under 2 years old, hold a majority in intractable cases, and the ratio was twice that of the control group. 2) A result of skin test was generally lower positive rate in the intractable group as compared to the control group. However, a result of prick test for buckwheat antigen in the intractable group showed higher positive rate than that in the control group. The intractable group tended to be separated into two extreme groups, one which showed positive to most of inhaled antigens in skin test, and another which showed negative to all antigens. 3) As a result of RAST, 13% of the intractable group showed positive to egg white out of food antigens, and it was three times the ratio of positive in the control group. One case showed strong positive to rice. 4) Two thirds of cases which showed positive in RAST for food antigens showed negative in prick test. 5) Total IgE in the serum of the intractable group was clearly lower in values than that of the control group. (Tsunoda, M.)
Evaluating the use of dedicated swab for rapid antigen detection ...
African Journals Online (AJOL)
Evaluating the use of dedicated swab for rapid antigen detection testing in group a ... African Journal of Clinical and Experimental Microbiology ... Several generations of rapid antigen detection tests (RADTs) have been developed to facilitate ...
Prostate-Specific Antigen (PSA) Test
... Cancer Prostate Cancer Screening Research Prostate-Specific Antigen (PSA) Test On This Page What is the PSA ... parts of the body before being detected. The PSA test may give false-positive or false-negative ...
Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool
Directory of Open Access Journals (Sweden)
Flávio da Silva Mesquita
2017-05-01
Full Text Available Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Resumo: Objetivo: Avaliar o teste QuickVue® RSV Test Kit (QUIDEL Corp, CA, EUA para o diagn
Polyclonal antibodies for the detection of Trypanosoma cruzi circulating antigens.
Directory of Open Access Journals (Sweden)
Edith S Málaga-Machaca
2017-11-01
Full Text Available Detection of Trypanosoma cruzi antigens in clinical samples is considered an important diagnostic tool for Chagas disease. The production and use of polyclonal antibodies may contribute to an increase in the sensitivity of immunodiagnosis of Chagas disease.Polyclonal antibodies were raised in alpacas, rabbits, and hens immunized with trypomastigote excreted-secreted antigen, membrane proteins, trypomastigote lysate antigen and recombinant 1F8 to produce polyclonal antibodies. Western blot analysis was performed to determine specificity of the developed antibodies. An antigen capture ELISA of circulating antigens in serum, plasma and urine samples was developed using IgY polyclonal antibodies against T. cruzi membrane antigens (capture antibody and IgG from alpaca raised against TESA. A total of 33 serum, 23 plasma and 9 urine samples were analyzed using the developed test. Among serum samples, compared to serology, the antigen capture ELISA tested positive in 55% of samples. All plasma samples from serology positive subjects were positive in the antigen capture ELISA. All urine positive samples had corresponding plasma samples that were also positive when tested by the antigen capture ELISA.Polyclonal antibodies are useful for detection of circulating antigens in both the plasma and urine of infected individuals. Detection of antigens is direct evidence of the presence of the parasite, and could be a better surrogate of current infection status.
International Nuclear Information System (INIS)
Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Diaz Argudin, Tamara
2007-01-01
The disappearance of antigen e of hepatitis B in the presence of the plasmatic antibodies against antigen e may indicate a satisfactory therapeutic response in patients with chronic hepatitis B. The immuno-chromatographic test carried out in the diagnosis of diseases use different antibody combinations and may employ the avidin or streptavidin-biotin technology to develop a rapid immuno-chromatographic test for the detection of antibodies anti-antigen e in the plasma. They were detected in the laboratory by means of two fast immuno-chromatographic tests when using in one of them the avidin-biotin technology. These tests are carried out with a one-step competitive inhibition format and amplified or not with avidin-biotin. Monoclonal antibodies against antigen e obtained by cellular hybridization were used. Forty-six plasmatic samples classified as positive and negative to the anti-antigen antibodies were evaluated with a reference immunochromatographic test Advanced QualityTM. The possible expiry time of the biological reagents forming part of these tests were studied with accelerated thermal-stability experiments. The possible interference in the plasma of some of the biochemical compounds used in these trials was analyzed. Four murine monoclonal antibodies anti-antigen e were obtained and only one of them was used in these immunochromatographic tests with an anti-antigen polyclonal antibody conjugated with gold. Both tests and their stable biological reagents discriminated the positive and negative samples to the antibodies anti-antigen e, as well as the commercial test. There was no interference in the biochemical compounds studied in these tests. Both immuno-chromatographic tests made in the laboratory are useful to detect antibodies anti-antigen e in the plasma. The avidin-biotin increased the analytical sensitivity of this type of fast immuno-chromatographic test without altering its performance features. (Author)
Detection of gonococcal antigens in urine by radioimmunoassay
International Nuclear Information System (INIS)
Thornley, M.J.; Wilson, D.V.; Hormaeche, R.D. de; Coombs, R.R.A.; Oates, J.K.
1979-01-01
A method of detecting gonococcal antigens by solid-phase radioimmunoassay with radioactively labelled antibody is described. A specificity test has been developed that enables this method to be used to detect gonococcal antigens in urine sediments. When sediments from samples of urine from male patients with gonorrhoea were tested, 31 (74%) of 42 gave positive results, clearly distinguishing them from sediments from urine samples from men with non-specific urethritis, none of which was positive. Ten of 14 urine sediments from urine samples from women with gonorrhoea gave positive results, as did 3 of 18 sediments from urine samples from women patients without gonorrhoea.These experiments demonstrate that gonococcal antigens can be detected in urine by radioimmunoassay; the method could be useful in diagnosis if, after refinement, its sensitivity and specificity were to be increased. (author)
Radioimmunoassay for the detection of Australia-SH antigen
Energy Technology Data Exchange (ETDEWEB)
Gerhardt, H [Giessen Univ. (Germany, F.R.). Zentrum fuer Innere Medizin
1974-06-01
Among infectious diseases, hepatitis presents a great problem in all countries with a high medical standard. The number of Australia antigen-positive cases rises from year to year, due to the increase in drug-fixer hepatitis and blood transfusions. Highly sensitive and at the same time practicable methods are therefore required for the identification of Australia antigen carriers and their elimination as blood donors. The most sensitive of all currently used tests for the detection of Australia antigen is the 'solid phase' radioimmunoassay since it permits an objective and quantitative measurement of the antigen.
Directory of Open Access Journals (Sweden)
Daria Štefatić
2008-08-01
Full Text Available Colorectal cancer is one of the most common cancer types worldwide and it continues to be a serious public health problem. Early detection and diagnosis are of great importance in cancer management. At present, diagnostic blood tests are based on the detection of tumor-associated markers such as carcinoembryonic antigen (CEA, the cancer antigen CA19-9 for gastrointestinal cancer, CA15-3 for breast cancer or CA125 for ovarian cancer. The lack of sensitivity and specificity of these markers prevents their general use in cancer screening of an average risk population. Therefore, new cancer biomarkers or better screening methods are necessary to improve the diagnostics of the disease. This study was directed to the optimization of a diagnostic, enzyme linked immunosorbent assay (ELISA based test to identify and validate new serum markers, such as extracellular Protein Kinase A (ecPKA and Nicotinamide A-Meth- yltransferase (NNMT. In this type of assay, the cancer antigens are quantified indirectly - by detecting the presence of auto-antibodies against tumor proteins in human serum. The result of the optimization and validation process was in the case of ecPKA a reproducible and stable assay. In case of NNMT the assay was probably not sensitive enough.
Dengue NS1 Antigen - for Early Detection of Dengue Virus Infection
Directory of Open Access Journals (Sweden)
Amol Hartalkar
2015-08-01
Full Text Available Objectives: To evaluate the efficacy of NS1 antigen assay for early diagnosis of dengue virus infection in a tertiary care hospital. Methods: This cross sectional study was carried out in department of Medicine from August to December 2013. Total 100 patients with dengue fever were included. Complete blood count, alanine aminotransferase (ALT, aspartate aminotransferase (AST, Dengue NS1 antigen and IgM and IgG antibodies of dengue virus were done in all cases. Results: Of the 100 sera tested, 75% were positive for dengue virus infection based on dengue NS1 antigen, IgM antibody and IgG antibody. Dengue NS1 antigen and IgM, IgG antibody were able to detect dengue virus infection between day 1 to day 8 in 92% of samples, 86.7% of samples and 82.6% of samples respectively. Sixty nine percent (69% were found positive for dengue NS1 antigen, 65% were IgM positive and 62% were IgG positive. Based on the dengue NS1 antigen and IgM antibody combination, 74% were positive for dengue virus infections. Sensitivity of Dengue NS1 antigen was 92.3% and specificity of 74.28% in comparison to IgM antibody. Detection rate increased to 75%, based on the antigen and IgG antibody combination. Sensitivity of dengue NS1 antigen was 90.3% and specificity of 65.8% in comparison to IgG antibody. Conclusion: Dengue NS1 antigen is a useful, sensitive and specific test for early diagnosis of dengue virus infection and it improves diagnostic efficiency in combination with antibody test. Key words: Dengue fever, NS1 antigen. Introduction: Dengue fever (DF is the most common arboviral illness in humans. Each year, an estimated 50-100 million cases of dengue fever and 500,000 cases of dengue hemorrhagic fever occur worldwide, with 30000 deaths (mainly in children. Globally 2.5-3 billion people in approximately 112 tropical and subtropical countries are at risk of dengue.of samples respectively. Sixty nine percent (69% were found positive for dengue NS1 antigen, 65% were Ig
Development of recombinant antigen array for simultaneous detection of viral antibodies.
Directory of Open Access Journals (Sweden)
Yi Liu
Full Text Available Protein microarrays have been developed to study antibody reactivity against a large number of antigens, demonstrating extensive perspective for clinical application. We developed a viral antigen array by spotting four recombinant antigens and synthetic peptide, including glycoprotein G of herpes simplex virus (HSV type 1 and 2, phosphoprotein 150 of cytomegalovirus (CMV, Rubella virus (RV core plus glycoprotein E1 and E2 as well as a E1 peptide with the optimal concentrations on activated glass slides to simultaneously detect IgG and IgM against HSV1, HSV2, CMV and RV in clinical specimens of sera and cerebrospinal fluids (CSFs. The positive reference sera were initially used to measure the sensitivity and specificity of the array with the optimal conditions. Then clinical specimens of 144 sera and 93 CSFs were tested for IgG and IgM antibodies directed against HSV1, HSV2, CMV and RV by the antigen array. Specificity of the antigen array for viral antibodies detection was satisfying compared to commercial ELISA kits but sensitivity of the array varied relying on quality and antigenic epitopes of the spotting antigens. In short, the recombinant antigen array has potential to simultaneous detect multiple viral antibodies using minute amount (3 µl of samples, which holds the particularly advantage to detect viral antibodies in clinical CSFs being suspicious of neonatal meningitis and encephalitis.
Detection of hMPV antigen by EIA in clinical specimens.
Pancer, Katarzyna; Ciaćka, Agnieszka; Gut, Włodzimierz; Lipka, Bozena; Mierzejewska, Justyna; Milewska-Bobula, Bogumiła; Smorczewska-Kiljan, Anna; Jahnz-Rózyk, Karina; Litwińska, Bogumiła
2011-01-01
Human Metapneumovirus (hMPV) is one of the latest discovered viruses. It has been classified to Paramyxoviridae family. It is the second viral etiological agent, after RSV, which causes respiratory tract infections (RTI) in children, especially children below 5 years old. It is estimated that 5-25% of RTI in children is due to hMPV. In adults hMPV reinfections are bounded to upper respiratory tract infections. The aim of the study was to establish usefulness of ELISA test in detecting hMPV antigen and to analyze hMPV infection in connection to clinical diagnosis. 273 nasopharyngeal swabs from children (189 swabs) and adults (84 swabs) with respiratory tract infections collected from 2008 to 2010 were examined. Due to similarity of hMPV and RSV viruses and overlapping of their epidemic season rapid immunochromatographic test for RSV antigen detection was also performed in case of 120 samples, hMPV antigen was detected in 24.5% of all swabs (n = 67): in 0.0% probes in 2008, 29.0% in 2009 and 36.8% in first quarter of 2010. The highest rate ofhMPV infection was detected from summer of 2009 till the end of March 2010 (VIII-IX 2009 - 62.5%, X-XII 2009 - 44.1% and I-III 2010 -36.8%). We analyzed respiratory tract diseases reported in patients with hMPV infection. Infection due to hMPV was found in 26.5% of children and 24.0% of adults with recognized pneumonia, respectively in 28.4 and 17.6% of patients with bronchitis. Bronchiolitis was diagnosed in two children with hMPV. RSV and hMPV coinfections were confirmed in 15 out of 120 examined probes. Cross reaction pattern was excluded thanks to ELISA hMPV antigen test which was performed with suspension of RSV and thanks to statistical analysis. Coinfections were confirmed in 8% of pneumonia, 11% of bronchitis and 24.2% of the rest concomitant diagnoses. We found hMPV infection as the significant agent ofpneumonia not only in children but also in adults. ELISA hMPV antigen test can be used in diagnosis of etiological agent
Trbusek, J
2009-11-01
Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.
Infectious agents or their constituent parts (antigens or nucleic acids) can be detected in fresh, frozen, or fixed tissues or other specimens, using a variety of direct or indirect assays. The assays can be modified to yield the greatest sensitivity and specificity but in most cases a particular m...
Directory of Open Access Journals (Sweden)
Mohammadi M
2009-04-01
Full Text Available "nBackground: Anti-dsDNA antibodies frequently found in the sera Systemic Lupus Erythematosus patients, particularly in active disease stage. Nowadays exploit different eukaryotic and prokaryotic dsDNA as antigen source and different reagents as binder. The aim of this study to compared two dsDNA different sources and tow different kinds of reagents for binder in ELISA test. "nMethods: In this study bacterial genomic DNA from E.coli (ATCC 25922 and genomic DNA from calf thymus extracted with high purity and were used as antigens for IgG anti-dsDNA detection by ELISA. To coat dsDNA in microtiter wells, tow different kinds of reagents including methylated -BSA and poly-l-lysine (for pre-coating are used. Sera from systemic lupus erythematosus patients and from normal blood donors are used to assess sensitivity and specificity of our ELISA test in compared with IF test and commercial kits. "nResults: Our results displayed pre-coating of microtiter plates with methylated -BSA reduce nonspecific binding reaction and the relative sensitivity and specificity of ELISA increased when calf thymus DNA is employed as antigenic source in compared with IF test and commercial kits 80%, 88% and 100%, 98% respectively, but when E.coli DNA is used 73%, 69% and 85%, 79%, respectively. "nConclusion: The genomic DNA from calf thymus is a potentially useful source of antigen for detection of anti-dsDNA by ELISA. Also the use of methylatted- BSA could have an effective role in reducing of nonspecific binding reactions.
DETECTION OF PNEUMOCOCCAL CAPSULAR ANTIGEN IN THE PRESENCE OF PENICILLIN IN-VITRO
HOLLOWAY, Y; BOERSMA, WG; KUTTSCHRUTTER, H; SNIJDER, JAM
1993-01-01
Eight strains of Streptococcus pneumoniae were tested in vitro for their ability to produce capsular antigen in the presence of penicillin. It was found that, provided 10(6) to 10(7) pneumococci/ml were present, capsular antigen could be detected during the 72 h in which the experiment was
International Nuclear Information System (INIS)
Horenstein, A.L.; Feinstein, R.E.
1985-01-01
Solid-phase radioimmunoassays (SPRIA) are described for the detection of equine infectious anemia (EIA) viral antigen and antibodies. Protein-antigen P29 currently used in the agar-gel immunodiffusion (AGID) test was used as antigen in the SPRIA. The specificity of the reaction was assessed by inhibition with the antigen. The reaction of immune serum against EIA-virus antigen adsorbed to the wells, was completely inhibited by the antigen in solution. This property was applied in an indirect competitive SPRIA for the detection of viral protein P29. The detection threshold of the SPRIA for EIA virus protein was about 5 ng and about 1 ng of antibody can be detected. The assay is rapid, specific and sensitive and allows the testing of multiple serum samples with the advantage of employing a single secondary labelled antibody. (orig.)
[Diagnostic advantages of the test system "DS-EIA-HBsAg-0.01" for detection of HBV surface antigen].
Egorova, N I; Pyrenkova, I Iu; Igolkina, S N; Sharipova, I N; Puzyrev, V F; Obriadina, A P; Burkov, A N; Kornienko, N V; Fields, H A; Korovkin, A S; Shalunova, N V; Bektemirov, T A; Kuznetsov, K V; Koshcheeva, N A; Ulanova, T I
2009-01-01
The new highly sensitive test system "DS-EIA-HBsAg-0.01" (Priority Certificate No. 2006129019 of August 10, 2006) in detecting hepatitis B surface antigen (HBsAg) was assessed. The sensitivity of the test was estimated using the federal standards sample HBsAg 42-28-311-06, panels' samples Boston Biomedica Inc. (West Bridgewater, Mass, USA) and ZeptoMetrix Corp. (Buffalo, NY, USA). The findings have indicated that "DS-EIA-HBsAg-0.01" is equally effective in detecting different subtypes of HBsAg during a seroconversion period earlier than alternative assays. Along with its high analytical and diagnostic sensitivity, the system shows a high diagnostic specificity.
Prostate-Specific Antigen (PSA) Test: MedlinePlus Lab Test Information
... medlineplus.gov/labtests/prostatespecificantigenpsatest.html Prostate-Specific Antigen (PSA) Test To use the sharing features on this ... enable JavaScript. What is a prostate-specific antigen (PSA) test? A prostate-specific antigen (PSA) test measures ...
International Nuclear Information System (INIS)
Hui, Z.; Coulepis, A.G.; Gust, I.D.
1982-01-01
The sensitivity and specificity of two commercially available radioimmunosay tests (Austria II-125, Abbott Laboratories; and International CIS, Commissariat Alenergie Atomique-Oris Laboratoire des Produits Biomedicaux) and a reverse passive haemagglutination test (Hepatest, Wellcome) for detection of hepatitis B surface antigen were evaluated using the Australian hepatitis B reference panel of 25 sera, and a panel of 257 sera collected from patients with acute hepatitis B, chronic carriers of hepatitis B surface antigen and two populations in which hepatitis B virus infection is known to be endemic. The three techniques were found to be generally comparable in sensitivity and specificity. The advantages and disadvantages of each method are discussed
El Khadir, Mounia; Alaoui Boukhris, Samia; Benajah, Dafr-Allah; El Rhazi, Karima; Ibrahimi, Sidi Adil; El Abkari, Mohamed; Harmouch, Taoufiq; Nejjari, Chakib; Mahmoud, Mustapha; Benlemlih, Mohamed; Bennani, Bahia
2016-07-01
Finding a simple, accurate, and noninvasive diagnosis method is a substantial challenge for the detection of Helicobacter pylori. The aim of the present study was to compare the presence of H. pylori urease antigen in saliva with the presence of this bacterium in gastric mucosa. Saliva samples and gastric biopsies were taken from 153 consenting Moroccan patients. Saliva samples were analyzed using an immunochromatographic test for urease antigen H. pylori detection. Thereafter, the gastric biopsies were analyzed by histology and polymerase chain reaction (PCR) to detect this bacterium. From a total of 153 recruited Moroccan patients, H. pylori was detected in 28 (18.30%), 87 (57.24%), and 69 (45.10%) cases by saliva test, histology, and PCR, respectively. A significant association was observed between the presence of H. pylori antigen in saliva and age. However, no association was found with sex, H. pylori virulence factors, gastric disease outcome, and density of the bacterium on the gastric mucosa. Considering that only 90 patients presented concordant results on H. pylori diagnosis (positive or negative) by both histology and PCR, the immunochromatographic test showed very low sensitivity (29.79%) and high specificity (90.70%). Of these two tests, the positive and negative predictive values were 77.78% and 54.17%, respectively. The accuracy of the test for salivary detection of urease antigen H. pylori was 58.89%. This study demonstrated a low detection rate of H. pylori antigens in saliva compared with the presence of this bacterium in gastric mucosa, suggesting that saliva cannot be used as a suitable sample for the diagnosis of H. pylori in our study population. Copyright © 2016. Published by Elsevier Taiwan LLC.
Taylor, Janette; McPhie, Kenneth; Druce, Julian; Birch, Chris; Dwyer, Dominic E
2009-11-01
Twenty rapid antigen assays were compared for their ability to detect influenza using dilutions of virus culture supernatants from human isolates of influenza A H5N1 (clade 1 and 2 strains), H3N2 and H1N1 viruses, and influenza B. There was variation amongst the rapid antigen assays in their ability to detect different influenza viruses. Six of the 12 assays labeled as distinguishing between influenza A and B had comparable analytical sensitivities for detecting both influenza A H5N1 strains, although their ability to detect influenza A H3N2 and H1N1 strains varied. The two assays claiming H5 specificity did not detect either influenza A H5N1 strains, and the two avian influenza-specific assays detected influenza A H5N1, but missed some influenza A H3N2 virus supernatants. Clinical trials of rapid antigen tests for influenza A H5N1 are limited. For use in a pandemic where novel influenza strains are circulating (such as the current novel influenza A H1N1 09 virus), rapid antigen tests should ideally have comparable sensitivity and specificity for the new strains as for co-circulating seasonal influenza strains.
Directory of Open Access Journals (Sweden)
Priscila Oliveira Dos Santos
2015-02-01
Full Text Available Paracoccidioidomycosis (PCM is a life-threatening systemic disease and is a neglected public health problem in many endemic regions of Latin America. Though several diagnostic methods are available, almost all of them present with some limitations.A latex immunoassay using sensitized latex particles (SLPs with gp43 antigen, the immunodominant antigen of Paracoccidioides brasiliensis, or the monoclonal antibody mAb17c (anti-gp43 was evaluated for antibody or antigen detection in sera, cerebrospinal fluid (CSF, and bronchoalveolar lavage (BAL from patients with PCM due to P. brasiliensis. The gp43-SLPs performed optimally to detect specific antibodies with high levels of sensitivity (98.46%, 95% CI 91.7-100.0, specificity (93.94%, 95% CI 87.3-97.7, and positive (91.4% and negative (98.9% predictive values. In addition, we propose the use of mAb17c-SLPs to detect circulating gp43, which would be particularly important in patients with immune deficiencies who fail to produce normal levels of immunoglobulins, achieving good levels of sensitivity (96.92%, 95% CI 89.3-99.6, specificity (88.89%, 95% CI 81.0-94.3, and positive (85.1% and negative (97.8% predictive values. Very good agreement between latex tests and double immune diffusion was observed for gp43-SLPs (k = 0.924 and mAb17c-SLPs (k = 0.850, which reinforces the usefulness of our tests for the rapid diagnosis of PCM in less than 10 minutes. Minor cross-reactivity occurred with sera from patients with other fungal infections. We successfully detected antigens and antibodies from CSF and BAL samples. In addition, the latex test was useful for monitoring PCM patients receiving therapy.The high diagnostic accuracy, low cost, reduced assay time, and simplicity of this new latex test offer the potential to be commercialized and makes it an attractive diagnostic assay for use not only in clinics and medical mycology laboratories, but mainly in remote locations with limited laboratory infrastructure
Directory of Open Access Journals (Sweden)
Anak Agung Ayu Mirah Adi
2013-07-01
Full Text Available In order to study the distribution of Newcastle disease virus (NDV following infection, chickenswere experimentally infected with visceretropic velogenic NDV isolate. Monoclonal antibodies (mAbsagainst the NDV LaSota vaccine strain were then produced to detect viral antigen in the infectedorgans. The mAbs were firstly tested for their specificity by enzyme linked immunosorbent assay(ELISA using NDV and normal allantoic fluids as antigens. Eight mAbs specific against NDVwere isolated and two mAbs were used for immunodetection of NDV antigen in chicken’s tissues.By immunohistochemistry labeled streptavidin-biotin (LSAB staining NDV–antigen was detectedin paraffin embedded tissues of NDV-infected chickens. NDV antigen was not detected in noninfected chickens. In the infected chickens, high intensity of NDV antigen was detected in thelymphoid tissues, lung and intestine. The NDV antigen with a lesser intensity was detected in thebrain, trachea, liver and myocardium. This study shows that although viscerotropic velogenicNDV isolate can infect almost all organs, the main target of infection are lung, intestine andlymphoids tissues
International Nuclear Information System (INIS)
Fauchet, R.; Genetet, B.; Phengsavath
1981-01-01
The respective sensitivity threshold of immunoenzymology and radioimmunology in HBs antigen and antibody detection were compared and the optical density (o.d.) and counts per minute (cpm) values were correlated with the concentration in ng/ml of a given sample. The sensitivity comparison between RIA and EIA appears in favour of the former technique for both HBs antigen and HBs antibody detection. However the procedure tried here to detect HBs antibodies by immunoenzymology is simple, requires only the choice of neutralising antigenic pool and sensitivity threshold and could usefully be generalized for teams not authorized to handle radioelements. Quantification of the HBs antigen content in ng/ml is a difficult operation, needing great care in the dilution of the sera tested. The reproducibility is not perfect. The semi-quantitative RIA determination expressed in R.U. (radioimmunological units) seems adequate as a mean to follow the progress of an HBs antibody in both liver disease and vaccination [fr
Gurol, Yesim; Akan, Hulya; Izbirak, Guldal; Tekkanat, Zuhal Tazegun; Gunduz, Tehlile Silem; Hayran, Osman; Yilmaz, Gulden
2010-06-01
It is aimed to detect the sensitivity and specificity of rapid antigen detection of group A beta hemolytic streptococci from throat specimen compared with throat culture. The other goal of the study is to help in giving clinical decisions in upper respiratory tract infections according to the age group, by detection of sensitivity and positive predictive values of the rapid tests and throat cultures. Rapid antigen detection and throat culture results for group A beta hemolytic streptococci from outpatients attending to our university hospital between the first of November 2005 and 31st of December 2008 were evaluated retrospectively. Throat samples were obtained by swabs from the throat and transported in the Stuart medium and Quickvue Strep A [Quidel, San Diego, USA] cassette test was applied and for culture, specimen was inoculated on 5% blood sheep agar and identified according to bacitracin and trimethoprim-sulphametaxazole susceptibility from beta hemolytic colonies. During the dates between the first of November 2005 and 31st of December 2008, from 453 patients both rapid antigen detection and throat culture were evaluated. Rapid antigen detection sensitivity and specificity were found to be 64.6% and 96.79%, respectively. The positive predictive value was 80.95% whereas negative predictive value was 92.82%. Kappa index was 0.91. When the results were evaluated according to the age groups, the sensitivity and the positive predictive value of rapid antigen detection in children were 70%, 90.3% and in adults 59.4%, 70.4%. When bacterial infection is concerned to prevent unnecessary antibiotic use, rapid streptococcal antigen test (RSAT) is a reliable method to begin immediate treatment. To get the maximum sensitivity of RSAT, the specimen collection technique used and education of the health care workers is important. While giving clinical decision, it must be taken into consideration that the sensitivity and the positive predictive value of the RSAT is quite
Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek
2011-01-01
The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.
Dussart, Philippe; Petit, Laure; Labeau, Bhety; Bremand, Laetitia; Leduc, Alexandre; Moua, David; Matheus, Séverine; Baril, Laurence
2008-08-20
We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV) infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France), and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA), pan-E Dengue Early ELISA (Panbio - Brisbane, Australia)-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad). We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222) was 87.4% (95% confidence interval: 82.3% to 91.5%); that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4%) after 15 minutes and 82.4% (95% CI: 76.8% to 87.2%) after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%). The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8%) and a specificity of 97.9% (95% CI: 88.9% to 99.9%). Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.
Directory of Open Access Journals (Sweden)
Philippe Dussart
Full Text Available BACKGROUND: We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France, and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA, pan-E Dengue Early ELISA (Panbio - Brisbane, Australia-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad. METHODS: We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. RESULTS: The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222 was 87.4% (95% confidence interval: 82.3% to 91.5%; that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4% after 15 minutes and 82.4% (95% CI: 76.8% to 87.2% after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%. The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8% and a specificity of 97.9% (95% CI: 88.9% to 99.9%. CONCLUSION: Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.
DEFF Research Database (Denmark)
Samuelsen, Simone V; Solov'yov, Ilia A.; Balboni, Imelda M.
2016-01-01
New techniques to detect and quantify antibodies to nucleic acids would provide a significant advance over current methods, which often lack specificity. We investigate the potential of novel antigens containing locked nucleic acids (LNAs) as targets for antibodies. Particularly, employing...... molecular dynamics we predict optimal nucleotide composition for targeting DNA-binding antibodies. As a proof of concept, we address a problem of detecting anti-DNA antibodies that are characteristic of systemic lupus erythematosus, a chronic autoimmune disease with multiple manifestations. We test the best...... that the novel method is a promising tool to create antigens for research and point-of-care monitoring of anti-DNA antibodies....
Directory of Open Access Journals (Sweden)
Dileep Tiwari
2017-04-01
Conclusion: Our study demonstrated that the newly developed liposome tuberculosis antigen card test detected antigens in our study population with approximately 97.48% sensitivity and 95.79% specificity. This is the first study to report the liposomal encapsulation of culture filtrate proteins from M. tuberculosis for diagnostic application.
Chaya, Dr; Parija, Subhash Chandra
2013-07-01
Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.
[The lysate and recombinant antigens in ELISA-test-systems for diagnostic of herpes simplex].
Ganova, L A; Kovtoniuk, G V; Korshun, L N; Kiseleva, E K; Tereshchenko, M I; Vudmaska, M I; Moĭsa, L N; Shevchuk, V A; Spivak, N Ia
2014-08-01
The lysate and recombinant antigens of various production included informula of ELISA-test-systems were analyzed. The ELISA-test-systems are used for detection of IgG to Herpes simplex virus type I and II. For testing the panel of serums PTH 201 (BBI Inc.) were used. The samples of this panel contain antibodies to Herpes simplex virus type I and II in mixed titers. The 69 serums of donors were used too (17 samples had IgG to Herpes simplex virus type I, 23 samples to Herpes simplex virus type II and 29 samples had no antibodies to Herpes simplex virus). The diagnostic capacity of mixture of recombinant antigens gG1 Herpes simplex virus type I and gG2 Herpes simplex virus type II (The research-and-production complex "DiaprofMed") was comparable with mixture of lysate antigen Herpes simplex virus type I and II (Membrane) EIE Antigen ("Virion Ltd."). In the test-systems for differentiation of IgG to Herpes simplex virus type I the recombinant antigen gG1 Herpes simplex virus type I proved to be comparable with commercial analogue Herpes simplex virus-1 gG1M ("Viral Therapeutics Inc."'). At the same time, capacity to detect IgG to Herpes simplex virus type II in recombinant protein gG2 Herpes simplex virus type II is significantly higher than in its analogue Herpes simplex virus-2 gG2c ("Viral Therapeutics Inc.").
Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem
2015-05-01
Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.
Directory of Open Access Journals (Sweden)
Kazuki Morioka
Full Text Available We developed a lateral flow strip using monoclonal antibodies (MAbs which allows for rapid antigen detection and serotyping of foot-and-mouth disease virus (FMDV. This FMDV serotyping strip was able to detect all 7 serotypes and distinguish serotypes O, A, C and Asia1. Its sensitivities ranged from 10(3 to 10(4 of a 50% tissue culture infectious dose of each FMDV stain; this is equal to those of the commercial product Svanodip (Boehringer Ingelheim Svanova, Uppsala, Sweden, which can detect all seven serotypes of FMDV, but does not distinguish them. Our evaluation of the FMDV serotyping strip using a total of 118 clinical samples (vesicular fluids, vesicular epithelial emulsions and oral and/or nasal swabs showed highly sensitive antigen detection and accuracy in serotyping in accordance with ELISA or RT-PCR. To the best of our knowledge, this is the first report on any FMDV serotyping strip that provides both rapid antigen detection and serotyping of FMDV at the same time on one strip without extra devices. This method will be useful in both FMD-free countries and FMD-infected countries, especially where laboratory diagnosis cannot be carried out.
Detection and monitoring of human bocavirus 1 infection by a new rapid antigen test
Directory of Open Access Journals (Sweden)
A.H.L. Bruning
2016-05-01
Full Text Available Clinically relevant diagnosis of human bocavirus 1 (HBoV1 is challenging, as the virus is frequently detected in asymptomatic patients, and cofindings with other respiratory viruses are common. The clinical value of current diagnostic methods, such as PCR, is therefore low, and alternative diagnostic strategies are needed. We describe for the first time the use of an antigen detection assay for the rapid identification of HBoV1 in a paediatric patient with respiratory tract infection symptoms. We estimate the duration of active HBoV1 infection to be 6 days.
Little, Paul; Hobbs, F D Richard; Moore, Michael; Mant, David; Williamson, Ian; McNulty, Cliodna; Cheng, Ying Edith; Leydon, Geraldine; McManus, Richard; Kelly, Joanne; Barnett, Jane; Glasziou, Paul; Mullee, Mark
2013-10-10
To determine the effect of clinical scores that predict streptococcal infection or rapid streptococcal antigen detection tests compared with delayed antibiotic prescribing. Open adaptive pragmatic parallel group randomised controlled trial. Primary care in United Kingdom. Patients aged ≥ 3 with acute sore throat. An internet programme randomised patients to targeted antibiotic use according to: delayed antibiotics (the comparator group for analyses), clinical score, or antigen test used according to clinical score. During the trial a preliminary streptococcal score (score 1, n=1129) was replaced by a more consistent score (score 2, n=631; features: fever during previous 24 hours; purulence; attends rapidly (within three days after onset of symptoms); inflamed tonsils; no cough/coryza (acronym FeverPAIN). Symptom severity reported by patients on a 7 point Likert scale (mean severity of sore throat/difficulty swallowing for days two to four after the consultation (primary outcome)), duration of symptoms, use of antibiotics. For score 1 there were no significant differences between groups. For score 2, symptom severity was documented in 80% (168/207 (81%) in delayed antibiotics group; 168/211 (80%) in clinical score group; 166/213 (78%) in antigen test group). Reported severity of symptoms was lower in the clinical score group (-0.33, 95% confidence interval -0.64 to -0.02; P=0.04), equivalent to one in three rating sore throat a slight versus moderate problem, with a similar reduction for the antigen test group (-0.30, -0.61 to -0.00; P=0.05). Symptoms rated moderately bad or worse resolved significantly faster in the clinical score group (hazard ratio 1.30, 95% confidence interval 1.03 to 1.63) but not the antigen test group (1.11, 0.88 to 1.40). In the delayed antibiotics group, 75/164 (46%) used antibiotics. Use of antibiotics in the clinical score group (60/161) was 29% lower (adjusted risk ratio 0.71, 95% confidence interval 0.50 to 0.95; P=0.02) and in the
Directory of Open Access Journals (Sweden)
Luigi Venco
2017-11-01
Full Text Available Abstract Background Heartworm antigen testing is considered sensitive and specific. Currently available tests are reported as detecting a glycoprotein found predominantly in the reproductive tract of the female worm and can reach specificity close to 100%. Main concerns regard sensitivity in the case of light infections, the presence of immature females or cases of all-male infections. Research and development have been aimed at increasing sensitivity. Recently, heat treatment of serum prior to antigen testing has been shown to result in an increase in positive antigen test results, presumably due to disruption of natural antigen–antibody complexes. Cross-reactions in dogs with both natural and experimental infections with Angiostrongylus vasorum and Spirocerca lupi have been reported, but cross-reactions with other helminths have not been extensively studied. In order to evaluate potential cross-reactivity with other canine and feline parasites, two studies were performed. Study 1: Live adults of Dirofilaria immitis, Dirofilaria repens, Toxocara canis, Toxocara cati, Dipylidium caninum, Taenia taeniaeformis and Mesocestoides spp. larvae were washed and incubated in tubes with saline solution. All worms were alive at the time of removal from the saline. Saline solutions containing excretory/secretory antigens were then tested for heartworm with six different, commercially available antigen tests. All results were evaluated blind by three of the authors. Study 2: Sera from dogs with natural infections by A. vasorum or D. repens, living in areas free of heartworm disease, were tested with the same tests before and after heat treatment (103 °C for 10 min. Results Results suggest that antigens detected by currently available tests are not specific for D. immitis. They may give positive results through detection of different parasites’ antigens that are normally not released into the bloodstream or released in a low amount and/or bound to
Honoré, S; Trillard, M; Ould-Hocine, Z; Lesprit, P; Deforges, L; Legrand, P
2004-10-01
Bacteriological confirmation of pneumonia (PNM) in hospitalized patients is often erratic or belated. Because of importance of prognosis, early adaptation of treatment requires an empirical antimicrobial therapy (generally aminopenicillin and macrolide combination). The starting therapeutic strategy should profit by a fast and reliable test asserting a pneumococcal etiology. The Binax Now S. pneumoniae (BNP) test allows an urinary pneumococcal antigen (UPA) detection using an immunochromatographic membrane assay within 15 minutes. We first evaluated the BNP test for 28 patients with pneumococcal PNM proved by culture, and 118 negative control patients without PNM. The BNP test was then evaluated by testing urine from 158 hospitalized patients with a clinical picture of PNM (community-acquired: 90, nosocomial: 68) for whom a research of urinary Legionella antigen (Binax Now) was prescribed and was positive for only two cases. 57 patients (36.1%) were hospitalized in ICU. The sensitivity was 71.4% (85.7% for the 21 bacteriemic PNM), and the specificity was 98.3%; that is consistent with previous published data. Among the 158 patients with PNM, UPA was detected in 17 cases (10.8%): 15 within the community-acquired PNM (16.7%) and 2 (2.9%) within the nosocomial cases. The pneumococcal etiology was confirmed by bacteriological samples in 7/17 patients (6 by blood cultures). The 10 others showed clinical and radiological features in agreement with a pneumococcal PNM. Among the 141 patients with negative AUP, S. pneumoniae was isolated from 6 of them (2 in blood cultures). The Binax Now S. pneumoniae test allowed a fast and reliable etiological diagnosis in 10.8% of hospitalized PNM (16.7% of the community-acquired cases) having a research of urinary Legionella antigen (conceiving with severity factors). So it could conduce to an improved adjustment of the starting antimicrobial therapy of hospitalized adult patients with PNM.
Energy Technology Data Exchange (ETDEWEB)
Mukuria, J C; Naiki, Masaharu; Hashimoto, Masato; Nishiura, Katsumi; Okabe, Masahiro; Kato, Shiro
1985-06-12
A relatively simple, specific and sensitive radioimmunoassay system has been developed for the detection of heterophile Hanganutziu-Deicher (H-D) antigen(s) and antibodies. The SVI-labeled H-D antigen-active molecule used for the assay is a bovine erythrocyte major glycoprotein previously found to have a strong H-D antigen potency. Different H-D antigen-active molecules were compared for heterophile H-D antigen potency. Eight different lung cancer tissues were assayed for H-D antigen. The sera from the 8 lung cancer patients were also screened by ELISA and RIA in an attmept to correlate expression of H-D antigen on tissues with elevation of H-D antibodies.
Directory of Open Access Journals (Sweden)
Simon F Dufresne
Full Text Available Mortality associated with invasive aspergillosis (IA remains high, partly because of delayed diagnosis. Detection of microbial exoantigens, released in serum and other body fluids during infection, may help timely diagnosis. In course of IA, Aspergillus galactomannan (GM, a well established polysaccharide biomarker, is released in body fluids including urine. Urine is an abundant, safely collected specimen, well-suited for point-of-care (POC testing, which could play an increasing role in screening for early disease. Our main objective was to demonstrate GM antigenuria as a clinically relevant biological phenomenon in IA and establish proof-of-concept that it could be translated to POC diagnosis. Utilizing a novel IgM monoclonal antibody (MAb476 that recognizes GM-like antigens from Aspergillus and other molds, we demonstrated antigenuria in an experimental animal IA model (guinea pig, as well as in human patients. In addition, we investigated the chemical nature of the urinary excreted antigen in human samples, characterized antigen detection in urine by immunoassays, described a putative assay inhibitor in urine, and indicated means of alleviation of the inhibition. We also designed and used a lateral flow immunochromatographic assay to detect urinary excreted antigen in a limited number of IA patient urine samples. In this study, we establish that POC diagnosis of IA based on urinary GM detection is feasible. Prospective studies will be necessary to establish the performance characteristics of an optimized device and define its optimal clinical use.
Detecting West Nile virus in owls and raptors by an antigen-capture assay.
Gancz, Ady Y; Campbell, Douglas G; Barker, Ian K; Lindsay, Robbin; Hunter, Bruce
2004-12-01
We evaluated a rapid antigen-capture assay (VecTest) for detection of West Nile virus in oropharyngeal and cloacal swabs, collected at necropsy from owls (N = 93) and raptors (N = 27). Sensitivity was 93.5%-95.2% for northern owl species but raptors.
Detecting West Nile Virus in Owls and Raptors by an Antigen-capture Assay
Gancz, Ady Y.; Campbell, Douglas G.; Barker, Ian K.; Lindsay, Robbin; Hunter, Bruce
2004-01-01
We evaluated a rapid antigen-capture assay (VecTest) for detection of West Nile virus in oropharyngeal and cloacal swabs, collected at necropsy from owls (N = 93) and raptors (N = 27). Sensitivity was 93.5%–95.2% for northern owl species but
Gish, R G; Gutierrez, J A; Navarro-Cazarez, N; Giang, K; Adler, D; Tran, B; Locarnini, S; Hammond, R; Bowden, S
2014-12-01
Early identification of chronic hepatitis B is important for optimal disease management and prevention of transmission. Cost and lack of access to commercial hepatitis B surface antigen (HBsAg) immunoassays can compromise the effectiveness of HBV screening in resource-limited settings and among marginalized populations. High-quality point-of-care (POC) testing may improve HBV diagnosis in these situations. Currently available POC HBsAg assays are often limited in sensitivity. We evaluated the NanoSign(®) HBs POC chromatographic immunoassay for its ability to detect HBsAg of different genotypes and with substitutions in the 'a' determinant. Thirty-seven serum samples from patients with HBV infection, covering HBV genotypes A-G, were assessed for HBsAg titre with the Roche Elecsys HBsAg II quantification assay and with the POC assay. The POC assay reliably detected HBsAg at a concentration of at least 50 IU/mL for all genotypes, and at lower concentrations for some genotypes. Eight samples with substitutions in the HBV 'a' determinant were reliably detected after a 1/100 dilution. The POC strips were used to screen serum samples from 297 individuals at risk for HBV in local clinical settings (health fairs and outreach events) in parallel with commercial laboratory HBsAg testing (Quest Diagnostics EIA). POC testing was 73.7% sensitive and 97.8% specific for detection of HBsAg. Although the POC test demonstrated high sensitivity over a range of genotypes, false negatives were frequent in a clinical setting. Nevertheless, the POC assay offers advantages for testing in both developed and resource-limited countries due to its low cost (0.50$) and immediately available results. © 2014 John Wiley & Sons Ltd.
Directory of Open Access Journals (Sweden)
Marleen eVan Coevorden-Hameete
2016-05-01
Full Text Available Autoimmune encephalitis (AIE is a group of disorders in which autoantibodies directed at antigens located on the plasma membrane of neurons induce severe neurological symptoms. In contrast to classical paraneoplastic disorders, AIE patients respond well to immunotherapy. The detection of neuronal surface autoantibodies in patients’ serum or CSF therefore has serious consequences for the patients’ treatment and follow-up and requires the availability of sensitive and specific diagnostic tests. This mini-review provides a guideline for both diagnostic and research laboratories that work on the detection of known surface autoantibodies and/or the identification of novel surface antigens. We discuss the strengths and pitfalls of different techniques for anti-neuronal antibody detection: 1 Immunohistochemistry and immunofluorescence on rat/ primate brain sections, 2 Immunocytochemistry of living cultured hippocampal neurons, 3 Cell Based Assay (CBA. In addition, we discuss the use of immunoprecipitation and mass spectrometry analysis for the detection of novel neuronal surface antigens, which is a crucial step in further disease classification and the development of novel CBAs.
Directory of Open Access Journals (Sweden)
Matthew R Krecic
2017-12-01
Full Text Available Objectives The objective of this study was to compare the diagnostic sensitivities and specificities of WITNESS FeLV-FIV (Zoetis and SNAP FIV/FeLV Combo Test (IDEXX for the detection of FeLV p27 antigen in the sera of experimentally feline leukemia virus (FeLV-infected cats. Methods Diagnostic sensitivities of WITNESS and SNAP were determined through testing of 47 serum samples collected from cats day 56 post-experimental infection with a virulent FeLV Rickard strain. Successful experimental infection was confirmed based on observation of FeLV antigen and proviral DNA in anti-coagulated (EDTA whole-blood samples by immunofluorescent antibody (IFA test and PCR, respectively. Diagnostic specificities of both tests were determined through testing of sera of 92 laboratory-housed, non-FeLV-exposed specific pathogen-free (SPF cats. Results Forty-one of 47 blood samples were IFA positive, whereas all 47 samples were PCR positive. All 92 non-FeLV-infected SPF cats were IFA and PCR negative. In comparison to IFA as the reference method, both WITNESS and SNAP tests yielded equivalent sensitivities and specificities of 100% and 97.8%, respectively. In comparison to PCR as the reference method, both WITNESS and SNAP tests likewise performed equivalently, with sensitivities and specificities of 91.5% and 100%, respectively. Conclusions and relevance Sensitivity and specificity of WITNESS FeLV-FIV for identifying FeLV p27 antigen in the sera of these experimentally FeLV-infected and non-FeLV-exposed SPF cats equaled those of the SNAP FIV/FeLV Combo Test. However, all positive results, regardless of the point-of-care test used, should be confirmed before making clinical decisions such as segregation from other cats or euthanasia.
Antigen detection of rabies virus in brain smear using direct Rapid Immunohistochemistry Test
Directory of Open Access Journals (Sweden)
Damayanti R
2014-03-01
Full Text Available Rabies is zoonotic disease caused by a fatal, neurotropic virus. Rabies virus is classified into the Genus of Lyssavirus under the yang family of Rhabdoviridae. Rabies affecting hot- blooded animals, as well as human. Dogs, cats, monkeys are the vectors or reservoirs for rabies and the virus was transmitted through the saliva after infected animal’s bites. The aim of this study was to conduct rapid diagnosis to detect rabies viral antigen in brain smear using immunohistochemical (IHC method namely direct Rapid Immunohistochemical Test (dRIT. A total number of 119 brain samples were achieved from Bukittinggi Veterinary Laboratory, West Sumatra. Standardisation and validation of the method were compared to Fluorescent Antibody Test (FAT as a golden standard for rabies diagnosis. Results show that dRIT was a very good method, it can be performed within two hours without the need of fluorescent microscope. The samples were tested using FAT and from 119 samples tested, 80 (67.23% samples were positive for rabies and 39 (32.77% samples were negative for rabies whereas using dRIT showed that 78 (65.54% samples were positive for rabies and 41 (34.45% samples were negative for rabies. The dRIT results were validated by comparing them with FAT results as a golden standard for rabies. The relative sensitivity of dRIT to FAT was 97.5% and the relative specificity to FAT was 100% (with Kappa value of 0.976, stated as excellent. The achievement showed that dRIT is very potential diagnostic tool and is highly recommended to be used widely as a rapid diagnosis tool for rabies.
Prostatic specific antigen for prostate cancer detection
Directory of Open Access Journals (Sweden)
Lucas Nogueira
2009-10-01
Full Text Available Prostate-specific antigen (PSA has been used for prostate cancer detection since 1994. PSA testing has revolutionized our ability to diagnose, treat, and follow-up patients. In the last two decades, PSA screening has led to a substantial increase in the incidence of prostate cancer (PC. This increased detection caused the incidence of advanced-stage disease to decrease at a dramatic rate, and most newly diagnosed PC today are localized tumors with a high probability of cure. PSA screening is associated with a 75% reduction in the proportion of men who now present with metastatic disease and a 32.5% reduction in the age-adjusted prostate cancer mortality rate through 2003. Although PSA is not a perfect marker, PSA testing has limited specificity for prostate cancer detection, and its appropriate clinical application remains a topic of debate. Due to its widespread use and increased over-detection, the result has been the occurrence of over-treatment of indolent cancers. Accordingly, several variations as regards PSA measurement have emerged as useful adjuncts for prostate cancer screening. These procedures take into consideration additional factors, such as the proportion of different PSA isoforms (free PSA, complexed PSA, pro-PSA and B PSA, the prostate volume (PSA density, and the rate of change in PSA levels over time (PSA velocity or PSA doubling time. The history and evidence underlying each of these parameters are reviewed in the following article.
Prostatic specific antigen for prostate cancer detection.
Nogueira, Lucas; Corradi, Renato; Eastham, James A
2009-01-01
Prostate-specific antigen (PSA) has been used for prostate cancer detection since 1994. PSA testing has revolutionized our ability to diagnose, treat, and follow-up patients. In the last two decades, PSA screening has led to a substantial increase in the incidence of prostate cancer (PC). This increased detection caused the incidence of advanced-stage disease to decrease at a dramatic rate, and most newly diagnosed PC today are localized tumors with a high probability of cure. PSA screening is associated with a 75% reduction in the proportion of men who now present with metastatic disease and a 32.5% reduction in the age-adjusted prostate cancer mortality rate through 2003. Although PSA is not a perfect marker, PSA testing has limited specificity for prostate cancer detection, and its appropriate clinical application remains a topic of debate. Due to its widespread use and increased over-detection, the result has been the occurrence of over-treatment of indolent cancers. Accordingly, several variations as regards PSA measurement have emerged as useful adjuncts for prostate cancer screening. These procedures take into consideration additional factors, such as the proportion of different PSA isoforms (free PSA, complexed PSA, pro-PSA and B PSA), the prostate volume (PSA density), and the rate of change in PSA levels over time (PSA velocity or PSA doubling time). The history and evidence underlying each of these parameters are reviewed in the following article.
Detection of toxoplasma gondii antigens in sera from experimentally infected mice
International Nuclear Information System (INIS)
Shojaee, S.; Keshavarz, H.; Rezaian, M.; Mohebali, M.
2007-01-01
Detection of Toxoplasma antigen in serum of mice by Immunoblotting. strain. IgG isolated from rabbits that were immunized with T. gondii Immunoblotting was performed to detect T. gondii antigens in sera of mice. Serum samples from mice experimentally infected with T. gondii RH strain. The value of Immunoblotting in diagnosis of toxoplasmosis in acute stage of infection. The antigen bands detected in serum sample of mice were experimentally infected with T. gondii tachyzoite in immunoblotting. Six bands demonstrated on seventh post infection day six bands were identified. Similarly on sixth day four bands, on day five three bands and on fourth post infection day two bands were identified. No band was detected in control group sera. Immunoblotting is a sensitive method for diagnosis of acute stage of toxoplasmosis. (author)
Hesketh, J; Dobbelaere, D; Griffin, J F; Buchan, G
1993-01-01
The expression of interleukin-2 receptors (IL-2R) and proliferating cell nuclear antigens (PCNA) were compared for their usefulness as markers of lymphocyte activation. Heterologous polyclonal (anti-bovine IL-2R) and monoclonal (anti-human PCNA) antibodies were used to detect the expression of these molecules on activated deer lymphocytes. Both molecules were co-expressed on blast cells which had been activated with mitogen [concanavalin A (Con A)]. There was detectable up-regulation of IL-2R expression in response to antigen [Mycobacterium bovis-derived purified protein derivative (PPD)] stimulation while PCNA expression mimicked lymphocyte transformation (LT) reactivity. PCNA expression was found to more accurately reflect both antigen- and mitogen-activated lymphocyte activation, as estimated by LT activity. The expression of PCNA was used to identify antigen reactive cells from animals exposed to M. bovis. A very low percentage (1.1 +/- 0.4%) of peripheral blood lymphocytes from non-infected animals could be stimulated to express PCNA by in vitro culture with antigen (PPD). Within the infected group both diseased and healthy, 'in-contact', animals expressed significantly higher levels of PCNA upon antigen stimulation. PMID:8104884
Yoon, Jeong-Yeol; Heinze, Brian C.; Gamboa, Jessica; You, David J.
2009-05-01
Virus antigens of avian influenza subtype H3N2 were detected on two different microfluidic platforms: microchannel and droplet. Latex immunoagglutination assays were performed using 920-nm highly carboxylated polystyrene beads that are conjugated with antibody to avian influenza virus. The bead suspension was merged with the solutions of avian influenza virus antigens in a Y-junction of a microchannel made by polydimethylsiloxane soft lithography. The resulting latex immunoagglutinations were measured with two optical fibers in proximity setup to detect 45° forward light scattering. Alternatively, 10 μL droplets of a bead suspension and an antigen solution were merged on a superhydrophobic surface (water contact angle = 155°), whose movement was guided by a metal wire, and 180° back light scattering is measured with a backscattering optical probe. Detection limits were 0.1 pg mL-1 for both microchannel with proximity fibers and droplet microfluidics, thanks to the use of micro-positioning stages to help generate reproducible optical signals. Additionally, optical waveguide was tested by constructing optical waveguide channels (filled with mineral oil) within a microfluidic device to detect the same light scattering. Detection limit was 0.1 ng mL-1 for an optical waveguide device, with a strong potential of improvement in the near future. The use of optical waveguide enabled smaller device setup, easier operation, smaller standard deviations and broader linear range of assay than proximity fiber microchannel and droplet microfluidics. Total assay time was less than 10 min.
Simultaneous detection of Hepatitis B surface antigen and its antibody by radioimmunoassay
International Nuclear Information System (INIS)
Crouzat-Reynes, Gerard; Perigois, Francois; Lecureuil, Michel; Lejeune, Bernard
1981-01-01
The authors describe an original radioimmunoassay which allows the simultaneous detection of hepatitis B surface antigen and its antibody in a biological sample. Antigen and antibody are indiscriminately detected in a first step and then distinguished in a second step using the same reagents [fr
DETECTION OF CANINE PARVOVIRUS ANTIGEN IN DOGS IN KUMASI, GHANA.
Folitse, R D; Kodie, D O; Amemor, E; Dei, D; Tasiame, W; Burimuah, V; Emikpe, B O
2018-01-01
Canine Parvovirus (CPV) in dogs has been documented in many countries. However, evidence of the infection is scanty in Ghana. This study was conducted to detect canine parvovirus antigen in dogs presented with diarrhoea to the Government Veterinary Clinic in Kumasi, Ghana. Faecal samples from 72 dogs presented with diarrhoea were tested for the presence of canine parvovirus antigen using commercially available rapid test kit (BIT ® Rapid Colour Canine Parvovirus Ag Test Kit, BIOINDIST Co. Ltd, Korea) based on the principle of immunochromatography. Influence of breed, sex, age, vaccination history and the nature of diarrhoea were assessed. Data obtained was analysed with SPSS and subjected to the chi-square test. Significance was at α 0.05 . We found 61.11% tested positive (44/72) for CPV. Based on sex, 61.54% of males (20/33) and 60.61% of females tested positive (24/39). A total of 65.67% of samples from puppies below 6 months were positive. 56.25% of CPV vaccinated dogs and 70.83% of unvaccinated dogs were positive respectively. 69.05% of samples from haemorrhagic diarrhoeic dogs and 50.00% from non-haemorrhagic diarrhoeic dogs were positive of CPV. The study is the first documented evidence of the existence of CPV in Ghana. It also revealed that absence of bloody diarrhoea does not necessarily rule out CPV infection.
DETECTION OF CANINE PARVOVIRUS ANTIGEN IN DOGS IN KUMASI, GHANA
Folitse, R. D; Kodie, D.O; Amemor, E.; Dei, D.; Tasiame, W.; Burimuah, V.; Emikpe, B.O
2018-01-01
Background: Canine Parvovirus (CPV) in dogs has been documented in many countries. However, evidence of the infection is scanty in Ghana. This study was conducted to detect canine parvovirus antigen in dogs presented with diarrhoea to the Government Veterinary Clinic in Kumasi, Ghana. Materials and Methods: Faecal samples from 72 dogs presented with diarrhoea were tested for the presence of canine parvovirus antigen using commercially available rapid test kit (BIT® Rapid Colour Canine Parvovirus Ag Test Kit, BIOINDIST Co. Ltd, Korea) based on the principle of immunochromatography. Influence of breed, sex, age, vaccination history and the nature of diarrhoea were assessed. Data obtained was analysed with SPSS and subjected to the chi-square test. Significance was at α0.05 Results: We found 61.11% tested positive (44/72) for CPV. Based on sex, 61.54% of males (20/33) and 60.61% of females tested positive (24/39). A total of 65.67% of samples from puppies below 6 months were positive. 56.25% of CPV vaccinated dogs and 70.83% of unvaccinated dogs were positive respectively. 69.05% of samples from haemorrhagic diarrhoeic dogs and 50.00% from non-haemorrhagic diarrhoeic dogs were positive of CPV. Conclusion: The study is the first documented evidence of the existence of CPV in Ghana. It also revealed that absence of bloody diarrhoea does not necessarily rule out CPV infection. PMID:29302647
[The clinical value of urinary antigen detection of Legionella pneumonia].
Jiang, Luxi; Chen, Yu; Xia, Shuyue; Ma, Jiangwei; Zhao, Hongwen; Lu, Ye; Tao, Sixu; Zhao, Li
2015-01-01
To investigate the clinical value of urinary antigen detection of Legionella, and to describe the clinical characteristics of Legionella pneumonia. Patients with suspected Legionella pneumonia were enrolled from the Respiratory departments of 3 tertiary hospitals in Shenyang during May 2011 to November 2013. Urinary Legionella antigen was detected for all the enrolled patients. Bacterial culture, polymerase chain reaction (PCR) for Legionella, and double Legionella antibody detection in sera were performed for each patient whose urinary antigen was positive. Patients confirmed to have Legionella pneumonia were pooled and analyzed. Totally 13 cases presenting with pneumonia were positive for Legionella by the urinary antigen method, and in one of them Legionella strain was isolated from the secretion of lower respiratory tract. PCR detection was performed in 8 patients, and 4 of them were positive. Legionella antibody detection was performed in 12 patients, and 7 of them were positive. Nine patients had a history of exposure to Legionella high-risk environments. The characteristics of the cases with Legionella pneumonia were as follows: characteristic orange sputum in 4 patients, digestive symptoms in 6, neurologic disorders in 8, hyponatremia in 10, hypoxia with oxygenation index 130) in 8 patients . Chest CT scan showed bilateral involvement in 6, ground-glass opacity combined with consolidation in 11, and moderate pleural effusion in 11 patients. Cavity and reversed halo sign were found in one case, respectively. All of the patients received fluoroquinolone treatment, and 11 patients recovered completely while 2 died of multiple organ dysfunction syndrome, one of them was complicated with secondary infection. Detection of urinary antigen of Legionella is very useful in the diagnosis of Legionella pneumonia. Attention should be paid to exposure history to the high-risk environments and multiple organ impairment when Legionella infection is suspected. Orange sputum
Directory of Open Access Journals (Sweden)
Ana Teresa B.F. Antonangelo
2012-09-01
Full Text Available Babesiosis is one of the most important diseases affecting livestock agriculture worldwide. Animals from the subspecies Bos taurus indicus are more resistant to babesiosis than those from Bos taurus taurus. The genera Babesia and Plasmodium are Apicomplexa hemoparasites and share features such as invasion of red blood cells (RBC. The glycoprotein Duffy is the only human erythrocyte receptor for Pasmodium vivax and a mutation which abolishes expression of this glycoprotein on erythrocyte surfaces is responsible for making the majority of people originating from the indigenous populations of West Africa resistant to P. vivax. The current work detected and quantified the Duffy antigen on Bos taurus indicus and Bos taurus taurus erythrocyte surfaces using a polyclonal antibody in order to investigate if differences in susceptibility to Babesia are due to different levels of Duffy antigen expression on the RBCs of these animals, as is known to be the case in human beings for interactions of Plasmodium vivax-Duffy antigen. ELISA tests showed that the antibody that was raised against Duffy antigens detected the presence of Duffy antigen in both subspecies and that the amount of this antigen on those erythrocyte membranes was similar. These results indicate that the greater resistance of B. taurus indicus to babesiosis cannot be explained by the absence or lower expression of Duffy antigen on RBC surfaces.
Detection of Rabies antigen in brains of suspected Rabid dogs ...
African Journals Online (AJOL)
Objective: To detect the presence of rabies antigen in brains of suspected rabid dogs. Materials and Methods: Ninety six (96) brain specimens from suspected rabid dogs were examined for the presence of rabies antigen using Seller's staining technique and enzyme immunoassay. Results: The two techniques were both ...
Wilkinson, H W; Fikes, B J
1981-01-01
Current methods used for the detection of whole-cell isolates of Legionella or for the detection of Legionella soluble antigens are technically impractical for many clinical laboratories. The purpose of this study was to explore practical alternatives. The results showed that whole cell isolates of Legionella pneumophila serogroups 1 to 6, Legionella bozemanii, Legionella dumoffii, Legionella gormanii, and Legionella micdadei were identified specifically by a simple slide agglutination test o...
El-Moamly, Amal Abdul-Rasheed; El-Sweify, Mohamed Aly; Hafez, Mohamad Abdul
2012-09-01
Lymphatic filariasis (LF) continues to be a major source of permanent disability and an impediment to socio-economic development in 73 countries where more than 1 billion people are at risk and over 120 millions are infected. The global drive to eliminate LF necessitates an increasing demand for valid, reliable and rapid diagnostic tests. This study aimed to assess the performance of the AD12 rapid format immunochromatographic test (ICT) to detect Wuchereria bancrofti circulating antigens, against the combined gold standard: TropBio Og4C3-ELISA (enzyme-linked immunosorbent assay) which detects circulating filarial antigen (CFA) and the nucleopore membrane filtration and microscopic examination. This prospective case-control study involved 647 asymptomatic migrant workers from filariasis-endemic countries. Of these specimens, 32 were positive for microfilaremia using the membrane filtration and microscopy, 142 positive by ELISA (of which 32 had microfilaremia), and 128 positive by the ICT (of which 31 had microfilaremia). The performance of the ICT was calculated against 32 true-positive and 90 true-negative cases. For the detection of CFA, the ICT had a sensitivity of 97% (95% confidence interval [CI] 91-103), specificity 100% (95% CI 100-100), Positive Predictive Value (PPV) 100% (95% CI 100-100), Negative Predictive Value (NPV) 99% (95% CI 97-101); and the total accuracy of the test was 99% (95% CI 98-101). The agreement between ICT and ELISA in detecting W. bancrofti antigens was excellent (kappa = 0.934; p = 0.000). In conclusion, the AD12-ICT test for the detection of W. bancrofti-CFA was sensitive and specific and comparable to the performance of ELISA. The ICT would be a useful additional test to facilitate the proposed strategies for control and elimination of LF. Because it is rapid, simple to perform, and does not require the use of special equipment, the ICT may be most appropriate in screening programs and in monitoring the possible risk of introducing
THE ANTIGEN-SPECIFIC CELL IN VITRO TESTS FOR POST-VACCINATION ANTIPLAGUE IMMUNITY FORMATION
Directory of Open Access Journals (Sweden)
A. N. Kulichenko
2017-01-01
Full Text Available The possibility of post-vaccination anti-plague immunity evaluation was researched using antigen-stimulated cells tests in vitro and cytometry analysis. The object of study — the blood samples of 17 people immunised by the live plague vaccine (Yersinia pestis EV epicutaneously. Blood taking was carried out before vaccination and after immunisation on 7 and on 21 days, in 3 and in 6 months. Intensity antigen reactivity of lymphocytes was detected by cell tests in vitro, analysing markers of early (CD45+CD3+CD25+ and late (CD45+CD3+HLA-DR+ lymphocyte activation using flow cytometry. The complex of water-soluble Y. pestis antigens and allergen — pestin PP was tested as antigen. The high stimulating potential was defined of the water-soluble antigens Y. pestis complex. It is shown that coefficient of stimulation of relative level T- lymphocytes which express receptors for IL-2 was positive for all observation times after immunisation. The coefficient of stimulation had maximum values at 21 days (56.37% and at 3 (47.41% months. In identifying HLADR-positive lymphocytes before vaccination, the negative coefficient of stimulation was indicated on 7 and 21 days and the positive coefficient of stimulation was indicated at 3 and at 6 months. Analysis of intensity expression of early and late lymphocyte activation markers dynamics showed the possibility and prospect of application of cellular in vitro tests for the laboratory evaluation of specific reactivity of cellular immunity in both the early (7 days and late (6 months periods after vaccination. The results can be the basis for developing a new algorithm for assessment of immunological effectiveness of vaccination people against plague. It is the algorithm based on the identification of lymphocyte activation markers by antigen stimulation in conditions in vitro.
Directory of Open Access Journals (Sweden)
Yuan-Cheng Cao
2015-01-01
Full Text Available This paper describes a combined antigen/antibody immunoassay implemented in a 96-well plate using fluorescent spectroscopic method. First, goat anti-human IgG was used to capture human IgG (model antigen; goat anti-human IgG (Cy3 or FITC was used to detect the model antigen; a saturating level of model antigen was then added followed by unlabelled goat anti-human IgG (model antibody; finally, Cy3 labelled rabbit anti-goat IgG was used to detect the model antibody. Two approaches were applied to the concomitant assay to analyze the feasibility. The first approach applied FITC and Cy3 when both targets were present at the same time, resulting in 50 ng/mL of the antibody detection limit and 10 ng/mL of antigen detection limit in the quantitative measurements of target concentration, taking the consideration of FRET efficiency of 68% between donor and acceptor. The sequential approach tended to lower the signal/noise (S/N ratio and the detection of the model antigen (lower than 1 ng/mL had better sensitivity than the model antibody (lower than 50 ng/mL. This combined antigen/antibody method might be useful for combined detection of antigens and antibodies. It will be helpful to screen for both antigen and antibody particularly in the situations of the multiserotype and high-frequency mutant virus infections.
Shen, Wen-Fan; Galula, Jedhan Ucat; Chang, Gwong-Jen J; Wu, Han-Chung; King, Chwan-Chuen; Chao, Day-Yu
2017-04-01
Early diagnosis of dengue virus (DENV) infection to monitor the potential progression to hemorrhagic fever can influence the timely management of dengue-associated severe illness. Nonstructural protein 1 (NS1) antigen detection in acute serum specimens has been widely accepted as an early diagnostic assay for dengue infection; however, lower sensitivity of the NS1 antigen-capture enzyme-linked immunosorbent assay (Ag-ELISA) in secondary dengue viral infection has been reported. In this study, we developed two forms of Ag-ELISA capable of detecting E-Ag containing virion and virus-like particles, and secreted NS1 (sNS1) antigens, respectively. The temporal kinetics of viral RNA, sNS1, and E-Ag were evaluated based on the in vitro infection experiment. Meanwhile, a panel of 62 DENV-2 infected patients' sera was tested. The sensitivity was 3.042 ng/mL and 3.840 ng/mL for sNS1 and E, respectively. The temporal kinetics of the appearance of viral RNA, E, NS1, and infectious virus in virus-infected tissue culture media suggested that viral RNAs and NS1 antigens could be detected earlier than E-Ag and infectious virus. Furthermore, a panel of 62 sera from patients infected by DENV Serotype 2 was tested. Treating clinical specimens with the dissociation buffer increased the detectable level of E from 13% to 92% and NS1 antigens from 40% to 85%. Inclusion of a low-pH glycine buffer treatment step in the commercially available Ag-ELISA is crucial for clinical diagnosis and E-containing viral particles could be a valuable target for acute DENV diagnosis, similar to NS1 detection. Copyright © 2015. Published by Elsevier B.V.
Prostate-specific antigen testing accuracy in community practice
Directory of Open Access Journals (Sweden)
Adams-Cameron Meg
2002-10-01
Full Text Available Abstract Background Most data on prostate-specific antigen (PSA testing come from urologic cohorts comprised of volunteers for screening programs. We evaluated the diagnostic accuracy of PSA testing for detecting prostate cancer in community practice. Methods PSA testing results were compared with a reference standard of prostate biopsy. Subjects were 2,620 men 40 years and older undergoing (PSA testing and biopsy from 1/1/95 through 12/31/98 in the Albuquerque, New Mexico metropolitan area. Diagnostic measures included the area under the receiver-operating characteristic curve, sensitivity, specificity, and likelihood ratios. Results Cancer was detected in 930 subjects (35%. The area under the ROC curve was 0.67 and the PSA cutpoint of 4 ng/ml had a sensitivity of 86% and a specificity of 33%. The likelihood ratio for a positive test (LR+ was 1.28 and 0.42 for a negative test (LR-. PSA testing was most sensitive (90% but least specific (27% in older men. Age-specific reference ranges improved specificity in older men (49% but decreased sensitivity (70%, with an LR+ of 1.38. Lowering the PSA cutpoint to 2 ng/ml resulted in a sensitivity of 95%, a specificity of 20%, and an LR+ of 1.19. Conclusions PSA testing had fair discriminating power for detecting prostate cancer in community practice. The PSA cutpoint of 4 ng/ml was sensitive but relatively non-specific and associated likelihood ratios only moderately revised probabilities for cancer. Using age-specific reference ranges and a PSA cutpoint below 4 ng/ml improved test specificity and sensitivity, respectively, but did not improve the overall accuracy of PSA testing.
Rubaba, O; Chimbari, M J; Soko, W; Manyangadze, T; Mukaratirwa, S
2018-06-01
Circulating cathodic antigen (CCA) tests for schistosomiasis are fast and less complicated allowing making them good candidates for routine qualitative screening for schistosomiasis at point of care. The urine-CCA has been evaluated for detection of S. mansoni with promising results. Its specificity and consistency in detecting S. haematobium infection in different endemic regions has been variable. This study validated a rapid urine-CCA cassette test for qualitative detection of S. haematobium infection in an S. haematobium endemic area with low S. mansoni prevalence. Microscopic examination for the standard urine filtration technique was used to validate the commercially available urine-CCA cassette test (rapid medical diagnostics ® ). The validation was done in a sample of primary school pupils (n = 420) aged 10-15 years in schools in the Jozini Municipality, KZN. There was a relationship between infection intensity and a positive urine-CCA test. Using the urine filtration method as the gold standard, the prevalence for S. haematobium was 40%, the accuracy of the CCA kit was 54.8%, sensitivity was 68.1% while the specificity was 45.8%. The positive predictive value was 45.82% while the negative predictive value was 68.05%. Both the urine filtration and the urine-CCA methods detected heavy (≥50 eggs/10 mL urine) and light infections at statistically significant levels. The overall accuracy, sensitivity and specificity of the urine-CCA cassette test were low. The urine-CCA cassette test performed much better for heavy infections than low infections (p < 0.05) implying that the kit may not be suitable for low endemic areas. Copyright © 2018 Elsevier B.V. All rights reserved.
Directory of Open Access Journals (Sweden)
Fred Luciano Neves Santos
Full Text Available The performance of serologic tests in chronic Chagas disease diagnosis largely depends on the type and quality of the antigen preparations that are used for detection of anti-Trypanosoma cruzi antibodies. Whole-cell T. cruzi extracts or recombinant proteins have shown variation in the performance and cross-reactivity. Synthetic chimeric proteins comprising fragments of repetitive amino acids of several different proteins have been shown to improve assay performances to detect Chagasic infections. Here, we describe the production of four chimeric T. cruzi proteins and the assessment of their performance for diagnostic purposes. Circular Dichroism spectra indicated the absence of well-defined secondary structures, while polydispersity evaluated by Dynamic Light Scattering revealed only minor aggregates in 50 mM carbonate-bicarbonate (pH 9.6, demonstrating that it is an appropriate buffering system for sensitizing microplates. Serum samples from T. cruzi-infected and non-infected individuals were used to assess the performance of these antigens for detecting antibodies against T. cruzi, using both enzyme-linked immunosorbent assay and a liquid bead array platform. Performance parameters (AUC, sensitivity, specificity, accuracy and J index showed high diagnostic accuracy for all chimeric proteins for detection of specific anti-T. cruzi antibodies and differentiated seropositive individuals from those who were seronegative. Our data suggest that these four chimeric proteins are eligible for phase II studies.
Paredes, Adriana; Sáenz, Patricia; Marzal, Miguel W; Orrego, Miguel A; Castillo, Yesenia; Rivera, Andrea; Mahanty, Siddhartha; Guerra-Giraldez, Cristina; García, Hector H; Nash, Theodore E
2016-07-01
Neurocysticercosis (NCC), an infection of the brain by Taenia solium (Ts) cysts, is the most common cause of adult-onset epilepsy in developing countries. Serological testing consists primarily of varying methods to detect antibodies in body fluids and more recently antigen (Ag) detection assays to identify individuals or animals with viable parasites. Antigen assays currently in use employ monoclonal antibodies (mAbs) raised against T. saginata, which have known cross reactivity to animal cestodes but are highly specific in human samples. We produced, characterized and tested 21 mAbs raised against T. solium whole cyst antigens, vesicular fluid or excretory secretory products. Reactivity of the TsmAbs against specific cyst structures was determined using immunofluorescence and immunohistochemistry on histological sections of Ts muscle cysts. Four TsmAbs reacted to vesicular space alone, 9 to the neck and cyst wall, one to the neck and vesicular space and 7 to the neck, cyst wall and vesicular space. An in-house ELISA assay to detect circulating Ts antigen, using the TsmAbs as capture antibodies and a rabbit polyclonal anti-Ts whole cyst antibody as a detector antibody demonstrated that eight of the 21 TsmAbs detected antigens in known NCC-positive human sera and three of these also in urine samples. Reactivity was expressed as normalized ratios of optical densities (OD positive control/OD negative control). Three TsmAbs had ratios >10 and five between 2 and 10. The TsmAbs have potential utility for the diagnosis and post-treatment monitoring of patients with viable NCC infections. Copyright © 2016 Elsevier Inc. All rights reserved.
White, Douglas A E; Giordano, Thomas P; Pasalar, Siavash; Jacobson, Kathleen R; Glick, Nancy R; Sha, Beverly E; Mammen, Priya E; Hunt, Bijou R; Todorovic, Tamara; Moreno-Walton, Lisa; Adomolga, Vincent; Feaster, Daniel J; Branson, Bernard M
2018-01-05
Newer combination HIV antigen-antibody tests allow detection of HIV sooner after infection than previous antibody-only immunoassays because, in addition to HIV-1 and -2 antibodies, they detect the HIV-1 p24 antigen, which appears before antibodies develop. We determine the yield of screening with HIV antigen-antibody tests and clinical presentations for new diagnoses of acute and established HIV infection across US emergency departments (EDs). This was a retrospective study of 9 EDs in 6 cities with HIV screening programs that integrated laboratory-based antigen-antibody tests between November 1, 2012, and December 31, 2015. Unique patients with newly diagnosed HIV infection were identified and classified as having either acute HIV infection or established HIV infection. Acute HIV infection was defined as a repeatedly reactive antigen-antibody test result, a negative HIV-1/HIV-2 antibody differentiation assay, or Western blot result, but detectable HIV ribonucleic acid (RNA); established HIV infection was defined as a repeatedly reactive antigen-antibody test result and a positive HIV-1/HIV-2 antibody differentiation assay or Western blot result. The primary outcomes were the number of new HIV diagnoses and proportion of patients with laboratory-defined acute HIV infection. Secondary outcomes compared reason for visit and the clinical presentation of acute HIV infection. In total, 214,524 patients were screened for HIV and 839 (0.4%) received a new diagnosis, of which 122 (14.5%) were acute HIV infection and 717 (85.5%) were established HIV infection. Compared with patients with established HIV infection, those with acute HIV infection were younger, had higher RNA and CD4 counts, and were more likely to have viral syndrome (41.8% versus 6.5%) or fever (14.3% versus 3.4%) as their reason for visit. Most patients with acute HIV infection displayed symptoms attributable to acute infection (median symptom count 5 [interquartile range 3 to 6]), with fever often
Sun, Xuecheng; Zhi, Shaotao; Lei, Chong; Zhou, Yong
2016-08-01
This paper presents a contactless detection method for detecting prostate specific antigen with a giant magnetoresistance sensor. In contactless detection case, the prostate specific antigen sample preparation was separated from the sensor that prevented the sensor from being immersed in chemical solvents, and made the sensor implementing in immediately reuse without wash. Experimental results showed that applied an external magnetic field in a range of 50 Oe to 90 Oe, Dynabeads with a concentration as low as 0.1 μg/mL can be detected by this system and could give an approximate quantitation to the logarithmic of Dynabeads concentration. Sandwich immunoassay was employed for preparing PSA samples. The PSA capture was implemented on a gold film modified with a self-assembled monolayer and using biotinylated secondary antibody against PSA and streptavidinylated Dynabeads. With DC magnetic field in the range of 50 to 90 Oe, PSA can be detected with a detection limit as low as 0.1 ng/mL. Samples spiked with different concentrations of PSA can be distinguished clearly. Due to the contactless detection method, the detection system exhibited advantages such as convenient manipulation, reusable, inexpensive, small weight. So, this detection method was a promising candidate in biomarker detection, especially in point of care detection.
BOERSMA, WG; LOWENBERG, A; HOLLOWAY, Y; KUTTSCHRUTTER, H; SNIJDER, JAM; KOETER, GH
Background Detection of pneumococcal antigen may help to increase the rate of diagnosis of pneumococcal pneumonia. This study was designed to determine the value of rapid detection of pneumococcal antigen in pleural fluid from patients with community acquired pneumonia. Methods Thoracentesis was
Turunen, H J
1983-01-01
A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of the antigen assay was confirmed by using guinea pig immunoglobulins from preimmunization sera. The sensitivity of the antigen assay was found to be at least 10 ng of antigen protein per ml. The suitability of the method for detecting antigens of T. gondii in different specimens was studied by experimental toxoplasma infection in mice. Antigenic components of T. gondii could be detected in different tissue specimens from infected animals from the first day after infection onwards. Toxoplasma antigen in serum and urine samples from infected mice reached detectable levels on day 2 after infection followed by a linear increase in antigen concentration in succeeding samples. This method might offer a valuable aid for a rapid etiological diagnosis also in human cases of acute toxoplasmosis. PMID:6345574
Directory of Open Access Journals (Sweden)
Muneki Hotomi
Full Text Available Since the incidence of penicillin-resistant Streptococcus pneumoniae has been increasing at an astonishing rate throughout the world, the need for accurate and rapid identification of pneumococci has become increasingly important to determine the appropriate antimicrobial treatment. We have evaluated an immunochromatographic test (ODK-0901 that detects pneumococcal antigens using 264 middle ear fluids (MEFs and 268 nasopharyngeal secretions (NPSs. A sample was defined to contain S. pneumoniae when optochin and bile sensitive alpha hemolytic streptococcal colonies were isolated by culture. The sensitivity and specificity of the ODK-0901 test were 81.4% and 80.5%, respectively, for MEFs from patients with acute otitis media (AOM. In addition, the sensitivity and specificity were 75.2% and 88.8%, respectively, for NPSs from patients with acute rhinosinusitis. The ODK-0901 test may provide a rapid and highly sensitive evaluation of the presence of S. pneumoniae and thus may be a promising method of identifying pneumococci in MEFs and NPSs.
Directory of Open Access Journals (Sweden)
Sofía Duque-Beltrán
2002-12-01
Full Text Available The present study developed and standardized an enzime-linked immunosorbent assay (ELISA to detect Giardia antigen in feces using rabbit polyclonal antibodies. Giardia cysts were purified from human fecal samples by sucrose and percoll gradients. Gerbils (Meriones unguiculatus were infected to obtain trophozoites. Rabbits were inoculated with either cyst or trophozoite antigens of 14 Colombian Giardia isolates to develop antibodies against the respective stages. The IgG anti-Giardia were purified by sequential caprylic acid and ammonium sulfate precipitation. A portion of these polyclonal antibodies was linked to alkaline phosphatase (conjugate. One hundred and ninety six samples of human feces, from different patients, were tested by parasitologic diagnosis: 69 were positive for Giardia cysts, 56 had no Giardia parasites, and 71 revealed parasites other than Giardia. The optimal concentration of polyclonal antibodies for antigen capture was 40 µg/ml and the optimal conjugate dilution was 1:100. The absorbance cut-off value was 0.24. The parameters of the ELISA test for Giardia antigen detection were: sensitivity, 100% (95% CI: 93.4-100%; specificity, 95% (95% CI: 88.6-97.6%; positive predictive value, 91% (95% CI: 81.4-95.9%; and negative predictive value, 100% (95% CI: 96.1-100%. This ELISA will improve the diagnosis of Giardia infections in Colombia and will be useful in following patients after treatment.
Detection of viral antigens by solid phase radioimmunoassay on polyethylene film
Energy Technology Data Exchange (ETDEWEB)
Prokudina, E N; Semenova, N P; Zhdanov, V M
1986-04-01
Polyethylene film, without any pretreatment, may serve as a solid phase (SP) for RIA. Viral antigens (HBsAg, and influenza virus) are detected by SP-RIA on the film with a sensitivity of about 2-3 ng/ml or 40-60 pg/assay. The use of polyethylene film allows one to record RIA autographically. The use of micro amounts of reagents and specimens tested is an added advantage. No special equipment is necessary, the method is inexpensive, easy to perform and may be used for mass screening. (Auth.). 7 refs.; 4 figs.
Molinos, Luis; Zalacain, Rafael; Menéndez, Rosario; Reyes, Soledad; Capelastegui, Alberto; Cillóniz, Catia; Rajas, Olga; Borderías, Luis; Martín-Villasclaras, Juan J; Bello, Salvador; Alfageme, Inmaculada; Rodríguez de Castro, Felipe; Rello, Jordi; Ruiz-Manzano, Juan; Gabarrús, Albert; Musher, Daniel M; Torres, Antoni
2015-10-01
Detection of the C-polysaccharide of Streptococcus pneumoniae in urine by an immune-chromatographic test is increasingly used to evaluate patients with community-acquired pneumonia. We assessed the sensitivity and specificity of this test in the largest series of cases to date and used logistic regression models to determine predictors of positivity in patients hospitalized with community-acquired pneumonia. We performed a multicenter, prospective, observational study of 4,374 patients hospitalized with community-acquired pneumonia. The urinary antigen test was done in 3,874 cases. Pneumococcal infection was diagnosed in 916 cases (21%); 653 (71%) of these cases were diagnosed exclusively by the urinary antigen test. Sensitivity and specificity were 60 and 99.7%, respectively. Predictors of urinary antigen positivity were female sex; heart rate≥125 bpm, systolic blood pressureantibiotic treatment; pleuritic chest pain; chills; pleural effusion; and blood urea nitrogen≥30 mg/dl. With at least six of all these predictors present, the probability of positivity was 52%. With only one factor present, the probability was only 12%. The urinary antigen test is a method with good sensitivity and excellent specificity in diagnosing pneumococcal pneumonia, and its use greatly increased the recognition of community-acquired pneumonia due to S. pneumoniae. With a specificity of 99.7%, this test could be used to direct simplified antibiotic therapy, thereby avoiding excess costs and risk for bacterial resistance that result from broad-spectrum antibiotics. We also identified predictors of positivity that could increase suspicion for pneumococcal infection or avoid the unnecessary use of this test.
He, Jing; Xiu, Bingshui; Wang, Guohua; Chen, Kun; Feng, Xiaoyan; Song, Xiaoguo; Zhu, Cuixia; Yang, Xiqin; Bai, Guanzhong; Ling, Shigan; Zhang, Heqiu
2011-08-01
Based on B cell epitope predictions, a recombinant antigen with multiple epitopes from four Hepatitis C Virus fragments (C, NS3, NS4 and NS5) were engineered. The recombinant gene was then highly expressed in E. coli. The non-modified and C-terminal-modified recombinant proteins were used for coating and biotin labeling, respectively, to establish the double-antigen sandwich ELISA. Ten positive reference samples confirmed by the CHIRON RIBA HCV 3.0 SIA kit were detected positive, Forty one plasma samples were positive among samples from 441 volunteers, which indicated that the recombinant antigen could readily react well with plasma HCV antibody. As critical reagents of double-antigen sandwich ELISA, the recombinant multi-epitope antigen and the C-terminal-modified and biotin-conjugated antigen show good antigenicity. In this study, we provide a simple approach to produce multiple epitopes within one recombinant protein in order to avoid the costly expression of less-effective pools of multiple proteins, which is the conventional strategy of diagnostic antigen production for HCV antibody detection.
The use of antigen-detection ELISA for the diagnosis of bovine trypanosomosis in Cote d'Ivoire
International Nuclear Information System (INIS)
Kone, P.; Komoin-Oka, C.; N'Depo, A.
1997-01-01
An Antigen ELISA (Ag-ELISA) detecting circulating antigens of trypanosomes was evaluated in the central region of Cote d'Ivoire for the serodiagnosis of cattle trypanosomosis. Of 1423 sera examined, only 43 were positive in the MHCT/BCT, 105 (7%) were detected using stained blood smears, and 74 (5%) were found positive using the Ag-ELISA. The predominant trypanosome species was T. brucei, being present in 84% of the positive samples as detected by the BCT, in 96% using stained bloodsmears, and in 72% by Ag-ELISA. T.vivax was detected less frequently. The serological (ELISA) test did not detect all positive animals as found by the haematological techniques. However, the two techniques should be used in a complementary way to improve the diagnosis of the disease. The results confirm that the prevalence of trypanosomes in cattle is low in the study area. The low prevalence can be due to prophylaxis and therapy of livestock in combination with successful tsetse trapping. (author). 4 refs, 2 figs, 4 tabs
The use of antigen-detection ELISA for the diagnosis of bovine trypanosomosis in Cote d`Ivoire
Energy Technology Data Exchange (ETDEWEB)
Kone, P [Laboratoire Regional de Pathologie Animale de Bouake (LANADA), Bouake (Cote d` Ivoire); Komoin-Oka, C; N` Depo, A [Laboratoire Central de Pathologie Animale de Bingerville (LANADA), Bingerville (Cote d` Ivoire)
1997-02-01
An Antigen ELISA (Ag-ELISA) detecting circulating antigens of trypanosomes was evaluated in the central region of Cote d`Ivoire for the serodiagnosis of cattle trypanosomosis. Of 1423 sera examined, only 43 were positive in the MHCT/BCT, 105 (7%) were detected using stained blood smears, and 74 (5%) were found positive using the Ag-ELISA. The predominant trypanosome species was T. brucei, being present in 84% of the positive samples as detected by the BCT, in 96% using stained bloodsmears, and in 72% by Ag-ELISA. T.vivax was detected less frequently. The serological (ELISA) test did not detect all positive animals as found by the haematological techniques. However, the two techniques should be used in a complementary way to improve the diagnosis of the disease. The results confirm that the prevalence of trypanosomes in cattle is low in the study area. The low prevalence can be due to prophylaxis and therapy of livestock in combination with successful tsetse trapping. (author). 4 refs, 2 figs, 4 tabs.
Arents, NL; van Zwet, AA; Thijs, JC; de Jong, A; Pool, MO; Kleibeuker, JH
Objective and design To evaluate the performance of the Helicobacter pylori stool antigen test (HpSA test) in detecting H. pylori infection and monitoring the effect of treatment. This was done in two separate studies using either a biopsy or the C-13-urea breath test based 'gold standard' (in
Effect of vaccination on parvovirus antigen testing in kittens.
Patterson, Erin V; Reese, Michael J; Tucker, Sylvia J; Dubovi, Edward J; Crawford, P Cynda; Levy, Julie K
2007-02-01
To determine the frequency and duration of feline panleukopenia virus (FPV) vaccine-induced interference with fecal parvovirus diagnostic testing in cats. Prospective controlled study. Sixty-four 8- to 10-week-old specific-pathogen-free kittens. Kittens were inoculated once with 1 of 8 commercial multivalent vaccines containing modified-live virus (MLV) or inactivated FPV by the SC or intranasal routes. Feces were tested for parvovirus antigen immediately prior to vaccination, then daily for 14 days with 3 tests designed for detection of canine parvovirus. Serum anti-FPV antibody titers were determined by use of hemagglutination inhibition prior to vaccination and 14 days later. All fecal parvovirus test results were negative prior to vaccination. After vaccination, 1 kitten had positive test results with test 1, 4 kittens had positive results with test 2, and 13 kittens had positive results with test 3. Only 1 kitten had positive results with all 3 tests, and only 2 of those tests were subjectively considered to have strongly positive results. At 14 days after vaccination, 31% of kittens receiving inactivated vaccines had protective FPV titers, whereas 85% of kittens receiving MLV vaccines had protective titers. Animal shelter veterinarians should select fecal tests for parvovirus detection that have high sensitivity for FPV and low frequency of vaccine-related test interference. Positive parvovirus test results should be interpreted in light of clinical signs, vaccination history, and results of confirmatory testing. Despite the possibility of test interference, the benefit provided by universal MLV FPV vaccination of cats in high-risk environments such as shelters outweighs the impact on diagnostic test accuracy.
Alderete, J F
1984-01-01
An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses durin...
Directory of Open Access Journals (Sweden)
P. R. Prathiush
Full Text Available Coproantigen detection of Echinococcosis in dogs by counter immunoelectrophoresis was standardized. Adult Echinococcus granulosus worms were obtained from intestine of a necropsied positive dog. Excretory-secretory antigen was prepared by culturing adult worms in Medium 199 (pH 7.4. Faeces of positive dog were collected and fecal supernatant was prepared and used for coproantigen detection. CIEP was carried out using tris-borate buffer (pH 8.0 at a constant current of 8mA/slide for 60 minutes. CIEP detected infection with both the antigens. [Vet World 2009; 2(11.000: 421-422
Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.
Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah
2017-01-01
Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.
International Nuclear Information System (INIS)
Bartorelli, A.; Accinni, R.
1981-01-01
This invention relates to novel antigens associated with breast carcinoma, anti-sera specific to said antigens, 125 I-labeled forms of said antigens and methods of detecting said antigens in serum or plasma. The invention also relates to a diagnostic kit containing standardised antigens or antisera or marked forms thereof for the detection of said antigens in human blood, serum or plasma. (author)
Huhtamo, Eili; Hasu, Essi; Uzcátegui, Nathalie Y; Erra, Elina; Nikkari, Simo; Kantele, Anu; Vapalahti, Olli; Piiparinen, Heli
2010-01-01
The increased traveling to dengue endemic regions and the numerous epidemics have led to a rise in imported dengue. The laboratory diagnosis of acute dengue requires several types of tests and often paired samples are needed for obtaining reliable results. Although several diagnostic methods are available, proper comparative data on their performance are lacking. To compare the performance of novel methods including a novel pan-DENV real-time RT-PCR and a commercially available NS1 capture-EIA in regard to IgM detection for optimizing the early diagnosis of DENV in travelers. A panel of 99 selected early phase serum samples of dengue patients was studied by real-time RT-PCR, NS1 antigen ELISA, IgM-EIA, IgG-IFA and cell culture virus isolation. The novel real-time RT-PCR was shown specific and sensitive for detection of DENV-1-4 RNA and suitable for diagnostic use. The diagnostic rate using combination of RNA and IgM detection was 99% and using NS1 and IgM detection 95.9%. The results of RNA and NS1 antigen detection disagreed in 15.5% of samples that had only RNA or NS1 antigen detected. The diagnostic rates of early samples are higher when either RNA or NS1 antigen detection is combined with IgM detection. Besides the differences in the RNA and NS1 detection assays, the observed discrepancy of results could suggest individual variation or differences in timing of these markers in patient serum. Copyright (c) 2009 Elsevier B.V. All rights reserved.
Detection of Burkholderia pseudomallei O-antigen serotypes in near-neighbor species
Directory of Open Access Journals (Sweden)
Stone Joshua K
2012-11-01
Full Text Available Abstract Background Burkholderia pseudomallei is the etiological agent of melioidosis and a CDC category B select agent with no available effective vaccine. Previous immunizations in mice have utilized the lipopolysaccharide (LPS as a potential vaccine target because it is known as one of the most important antigenic epitopes in B. pseudomallei. Complicating this strategy are the four different B. pseudomallei LPS O-antigen types: A, B, B2, and rough. Sero-crossreactivity is common among O-antigens of Burkholderia species. Here, we identified the presence of multiple B. pseudomallei O-antigen types and sero-crossreactivity in its near-neighbor species. Results PCR screening of O-antigen biosynthesis genes, phenotypic characterization using SDS-PAGE, and immunoblot analysis showed that majority of B. mallei and B. thailandensis strains contained the typical O-antigen type A. In contrast, most of B. ubonensis and B. thailandensis-like strains expressed the atypical O-antigen types B and B2, respectively. Most B. oklahomensis strains expressed a distinct and non-seroreactive O-antigen type, except strain E0147 which expressed O-antigen type A. O-antigen type B2 was also detected in B. thailandensis 82172, B. ubonensis MSMB108, and Burkholderia sp. MSMB175. Interestingly, B. thailandensis-like MSMB43 contained a novel serotype B positive O-antigen. Conclusions This study expands the number of species which express B. pseudomallei O-antigen types. Further work is required to elucidate the full structures and how closely these are to the B. pseudomallei O-antigens, which will ultimately determine the efficacy of the near-neighbor B serotypes for vaccine development.
Rahmadane, Ibnu; Certoma, Andrea F; Peck, Grantley R; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P; Bingham, John; Gardner, Ian A; Allen, John D
2017-11-01
Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0
Directory of Open Access Journals (Sweden)
Ibnu Rahmadane
2017-11-01
Full Text Available Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT, which is considered the reference (gold standard test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST. This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST
Immunoliposome-PCR: a generic ultrasensitive quantitative antigen detection system
Directory of Open Access Journals (Sweden)
He Junkun
2012-06-01
Full Text Available Abstract Background The accurate quantification of antigens at low concentrations over a wide dynamic range is needed for identifying biomarkers associated with disease and detecting protein interactions in high-throughput microarrays used in proteomics. Here we report the development of an ultrasensitive quantitative assay format called immunoliposome polymerase chain reaction (ILPCR that fulfills these requirements. This method uses a liposome, with reporter DNA encapsulated inside and biotin-labeled polyethylene glycol (PEG phospholipid conjugates incorporated into the outer surface of the liposome, as a detection reagent. The antigenic target is immobilized in the well of a microplate by a capture antibody and the liposome detection reagent is then coupled to a biotin-labeled second antibody through a NeutrAvidin bridge. The liposome is ruptured to release the reporter DNA, which serves as a surrogate to quantify the protein target using real-time PCR. Results A liposome detection reagent was prepared, which consisted of a population of liposomes ~120 nm in diameter with each liposome possessing ~800 accessible biotin receptors and ~220 encapsulated reporters. This liposome detection reagent was used in an assay to quantify the concentration of carcinoembryonic antigen (CEA in human serum. This ILPCR assay exhibited a linear dose–response curve from 10-10 M to 10-16 M CEA. Within this range the assay coefficient of variance was Conclusions The ILPCR assay has several advantages over other immuno-PCR methods. The reporter DNA and biotin-labeled PEG phospholipids spontaneously incorporate into the liposomes as they form, simplifying preparation of the detection reagent. Encapsulation of the reporter inside the liposomes allows nonspecific DNA in the assay medium to be degraded with DNase I prior to quantification of the encapsulated reporter by PCR, which reduces false-positive results and improves quantitative accuracy. The ability to
Kesli, Recep; Polat, Hakki; Terzi, Yuksel; Kurtoglu, Muhammet Guzel; Uyar, Yavuz
2011-12-01
Hepatitis C virus (HCV) is a global health care problem. Diagnosis of HCV infection is mainly based on the detection of anti-HCV antibodies as a screening test with serum samples. Recombinant immunoblot assays are used as supplemental tests and for the final detection and quantification of HCV RNA in confirmatory tests. In this study, we aimed to compare the HCV core antigen test with the HCV RNA assay for confirming anti-HCV results to determine whether the HCV core antigen test may be used as an alternative confirmatory test to the HCV RNA test and to assess the diagnostic values of the total HCV core antigen test by determining the diagnostic specificity and sensitivity rates compared with the HCV RNA test. Sera from a total of 212 treatment-naive patients were analyzed for anti-HCV and HCV core antigen both with the Abbott Architect test and with the molecular HCV RNA assay consisting of a reverse transcription-PCR method as a confirmatory test. The diagnostic sensitivity, specificity, and positive and negative predictive values of the HCV core antigen assay compared to the HCV RNA test were 96.3%, 100%, 100%, and 89.7%, respectively. The levels of HCV core antigen showed a good correlation with those from the HCV RNA quantification (r = 0.907). In conclusion, the Architect HCV antigen assay is highly specific, sensitive, reliable, easy to perform, reproducible, cost-effective, and applicable as a screening, supplemental, and preconfirmatory test for anti-HCV assays used in laboratory procedures for the diagnosis of hepatitis C virus infection.
Directory of Open Access Journals (Sweden)
Bakari Muhammad
2009-02-01
Full Text Available Abstract Background Identifying novel TB diagnostics is a major public health priority. We explored the diagnostic characteristics of antimycobacterial lymphocyte proliferation assays (LPA in HIV-infected subjects with latent or active TB. Methods HIV-infected subjects with bacille Calmette Guérin (BCG scars and CD4 counts ≥ 200 cells/mm3 entering a TB booster vaccine trial in Tanzania had baseline in vivo and in vitro immune tests performed: tuberculin skin tests (TST, LPA and five day assays of interferon gamma (IFN-γ release. Assay antigens were early secreted antigenic target 6 (ESAT-6, antigen 85 (Ag85, and Mycobacterium tuberculosis whole cell lysate (WCL. Subjects were screened for active TB at enrollment by history, exam, sputum smear and culture. We compared antimycobacterial immune responses between subjects with and without latent or active TB at enrollment. Results Among 1885 subjects screened, 635 had latent TB and 13 had active TB. Subjects with latent TB were more likely than subjects without TB to have LPA responses to ESAT-6 (13.2% vs. 5.5%, P Conclusion Lymphoproliferative responses to mycobacteria are detectable during HIV-associated active TB, and are less sensitive but more specific than TST. Trial registration ClinicalTrials.gov Identifier NCT00052195.
A comparative study of blood smear, QBC and antigen detection for diagnosis of malaria.
Parija, S C; Dhodapkar, Rahul; Elangovan, Subashini; Chaya, D R
2009-01-01
Rapid diagnosis is prerequisite for effective treatment and reducing mortality and morbidity of malaria. This study was taken up to compare the efficacy of various methods available, i.e., thick and thin smear, quantitative buffy coat (QBC), plasmodium lactate dehydrogenase and aldolase in blood of patient. A total of 411 samples were collected from patients presenting with classic symptoms of malaria. For traditional microscopy; thick and thin smears were prepared and stained with Leishman's stain, taking thick smear as gold standard, thin smear had a sensitivity and specificity of 54.8% and 100%, respectively. QBC and antigen detection was done using commercially available kits; out of 411 samples, QBC and Malariagen were positive in 66 and 62 cases, with a sensitivity of 78% and 75%, respectively. Leishman's thick smear, although cost effective, is difficult to interpret for inexperienced microscopists; so if facilities are available, QBC should be used for routine diagnosis. In places where facilities are not available, rapid, simple and easy to interpret antigen detection test can be used despite low sensitivity.
A comparative study of blood smear, QBC and antigen detection for diagnosis of malaria
Directory of Open Access Journals (Sweden)
Parija S
2009-04-01
Full Text Available Rapid diagnosis is prerequisite for effective treatment and reducing mortality and morbidity of malaria. This study was taken up to compare the efficacy of various methods available, i.e., thick and thin smear, quantitative buffy coat (QBC, plasmodium lactate dehydrogenase and aldolase in blood of patient. A total of 411 samples were collected from patients presenting with classic symptoms of malaria. For traditional microscopy; thick and thin smears were prepared and stained with Leishman′s stain, taking thick smear as gold standard, thin smear had a sensitivity and specificity of 54.8% and 100%, respectively. QBC and antigen detection was done using commercially available kits; out of 411 samples, QBC and Malariagen were positive in 66 and 62 cases, with a sensitivity of 78% and 75%, respectively. Leishman′s thick smear, although cost effective, is difficult to interpret for inexperienced microscopists; so if facilities are available, QBC should be used for routine diagnosis. In places where facilities are not available, rapid, simple and easy to interpret antigen detection test can be used despite low sensitivity.
Kalantri, Yatiraj; Hemvani, Nanda; Chitnis, D S
2009-06-01
Quantiferon TB gold (QFT-G) with recombinant antigen cocktail is well evaluated for diagnosis of pulmonary tuberculosis (PTB). However, diagnosis of extra-pulmonary tuberculosis (EPTB) is more difficult due to limitations of conventional techniques. This study compares recombinant antigens based QFT-G and low cost PPD based interferon test for the diagnosis of PTB and EPTB. IFNgamma release, with recombinant antigens and PPD, was assayed by ELISA from 140 cases of EPTB, 100 cases of PTB along with acid fast bacillus (AFB) detection, AFB culture on LJ and MGIT BACTEC. Sensitivity and specificity for QFT-G recombinant antigens was 84.29% and 96%, while for PPD based interferon was 70% and 84% for EPTB group. The sensitivity was far superior to AFB smear and culture for both the antigens. Nine samples were identified as non-tubercular mycobacteria (NTM) in the EPTB group and all were negative for QFT-G, but six of them were positive for PPD based test. Results of the study show that QFT-G using recombinant antigen is sensitive and specific for both PTB and EPTB diagnosis. The PPD based test is economic and offers comparable performance for PTB and EPTB diagnosis and also useful for diagnosis of NTM.
International Nuclear Information System (INIS)
Knauf, S.; Urbach, G.I.
1978-01-01
Ovarian tumor-associated antigen isolated from human tumor tissue was shown to have a different mobility from that of carcinoembryonic antigen (CEA) in both acrylamide gel electrophoresis and immunoelectrophoresis in agarose. The ovarian tumor antigen is composed of six species with different electrophoretic mobility in acrylamide gel electrophoresis. Three of these species were detected in Sephadex G-100 ovarian fraction OCA (from the void volume peak) and the other three species of lower apparent molecular weight were detected in fraction OCD (from the second peak). Fractions OCA and OCD did not share common antigenic determinants as determined by immunodiffusion. CEA was shown to share antigenic determinants with both OCA and OCD. A double-antibody radioimmunoassay capable of detecting nanogram quantities of plasma OCA was developed. In a preliminary study of ovarian cancer patients, OCA appeared to be a more sensitive marker for ovarian cancer than CEA. There was virtually no correlation (r 2 = 0.1) between OCA and CEA levels in these patients, as determined by radioimmunoassay
21 CFR 866.6010 - Tumor-associated antigen immunological test system.
2010-04-01
.... Class II (special controls). Tumor markers must comply with the following special controls: (1) A... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tumor-associated antigen immunological test system... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Tumor Associated Antigen...
Energy Technology Data Exchange (ETDEWEB)
Ertürk, Gizem [Department of Biotechnology, Lund University, Lund (Sweden); Department of Biology, Hacettepe University, Ankara (Turkey); Hedström, Martin [Department of Biotechnology, Lund University, Lund (Sweden); CapSenze HB, Medicon Village, SE-223 63 Lund (Sweden); Tümer, M. Aşkın [Department of Biology, Hacettepe University, Ankara (Turkey); Denizli, Adil [Department of Chemistry, Hacettepe University, Ankara (Turkey); Mattiasson, Bo, E-mail: Bo.Mattiasson@biotek.lu.se [Department of Biotechnology, Lund University, Lund (Sweden); CapSenze HB, Medicon Village, SE-223 63 Lund (Sweden)
2015-09-03
Prostate specific antigen (PSA) is a valuable biomarker for early detection of prostate cancer, the third most common cancer in men. Ultrasensitive detection of PSA is crucial to screen the prostate cancer in an early stage and to detect the recurrence of the disease after treatment. In this report, microcontact-PSA imprinted (PSA-MIP) capacitive biosensor chip was developed for real-time, highly sensitive and selective detection of PSA. PSA-MIP electrodes were prepared in the presence of methacrylic acid (MAA) as the functional monomer and ethylene glycol dimethacrylate (EGDMA) as the cross-linker via UV polymerization. Immobilized Anti-PSA antibodies on electrodes (Anti-PSA) for capacitance measurements were also prepared to compare the detection performances of both methods. The electrodes were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and cyclic voltammetry (CV) and real-time PSA detection was performed with standard PSA solutions in the concentration range of 10 fg mL{sup −1}–100 ng mL{sup −1}. The detection limits were found as 8.0 × 10{sup −5} ng mL{sup −1} (16 × 10{sup −17} M) and 6.0 × 10{sup −4} ng mL{sup −1} (12 × 10{sup −16} M) for PSA-MIP and Anti-PSA electrodes, respectively. Selectivity studies were performed against HSA and IgG and selectivity coefficients were calculated. PSA detection was also carried out from diluted human serum samples and finally, reproducibility of the electrodes was tested. The results are promising and show that when the sensitivity of the capacitive system is combined with the selectivity and reproducibility of the microcontact-imprinting procedure, the resulting system might be used successfully for real-time detection of various analytes even in very low concentrations. - Highlights: • Microcontact imprinting method was used for preparing the sensor chip for capacitive biosensing. • High sensitivity was obtained. • Good selectivity was
International Nuclear Information System (INIS)
Ertürk, Gizem; Hedström, Martin; Tümer, M. Aşkın; Denizli, Adil; Mattiasson, Bo
2015-01-01
Prostate specific antigen (PSA) is a valuable biomarker for early detection of prostate cancer, the third most common cancer in men. Ultrasensitive detection of PSA is crucial to screen the prostate cancer in an early stage and to detect the recurrence of the disease after treatment. In this report, microcontact-PSA imprinted (PSA-MIP) capacitive biosensor chip was developed for real-time, highly sensitive and selective detection of PSA. PSA-MIP electrodes were prepared in the presence of methacrylic acid (MAA) as the functional monomer and ethylene glycol dimethacrylate (EGDMA) as the cross-linker via UV polymerization. Immobilized Anti-PSA antibodies on electrodes (Anti-PSA) for capacitance measurements were also prepared to compare the detection performances of both methods. The electrodes were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and cyclic voltammetry (CV) and real-time PSA detection was performed with standard PSA solutions in the concentration range of 10 fg mL"−"1–100 ng mL"−"1. The detection limits were found as 8.0 × 10"−"5 ng mL"−"1 (16 × 10"−"1"7 M) and 6.0 × 10"−"4 ng mL"−"1 (12 × 10"−"1"6 M) for PSA-MIP and Anti-PSA electrodes, respectively. Selectivity studies were performed against HSA and IgG and selectivity coefficients were calculated. PSA detection was also carried out from diluted human serum samples and finally, reproducibility of the electrodes was tested. The results are promising and show that when the sensitivity of the capacitive system is combined with the selectivity and reproducibility of the microcontact-imprinting procedure, the resulting system might be used successfully for real-time detection of various analytes even in very low concentrations. - Highlights: • Microcontact imprinting method was used for preparing the sensor chip for capacitive biosensing. • High sensitivity was obtained. • Good selectivity was demonstrated. • Stability of
Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya
2015-01-01
The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.
Directory of Open Access Journals (Sweden)
Scott R Fry
2011-06-01
Full Text Available BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1 has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum. AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test. METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples. KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6% and 96% (95% CI: 92.2% to 99.8 respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1% and 96.7% specificity (95% CI: 82.8% to 99.9% compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers. CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.
Directory of Open Access Journals (Sweden)
H Miranzadeh
2008-12-01
Full Text Available Background: Ornithobilharziosis as one of the parasitic infections may give rise to serious economic problems in animal husbandry. The Aim of the study was to prepare and compare the somatic and excretory-secretory (ES antigens of O. turkestanicum in gel diffusion test. Methods: Excretory-secretory (ES and somatic antigens of Ornithobilharzia turkestanicum were prepared from collected worms from mesentric blood vessels of infected sheep. The laboratory bred rabbits were immunized with antigens and then antisera were prepared. The reaction of antigens and antisera was observed in gel diffusion test. Results: ES antigens of this species showed positive reaction with antisera raised against ES and also somatic antigens. Somatic antigens also showed positive reaction with antisera raised against somatic and also ES antigens. Conclusion: The antigenicity of O. turkestanicum ES and somatic antigens is the same in gel diffusion test.
Stavri, Henriette; Bucurenci, Nadia; Ulea, Irina; Costache, Adriana; Popa, Loredana; Popa, Mircea Ioan
2012-11-01
Purified protein derivative (PPD) is currently the only available skin test reagent used worldwide for the diagnosis of tuberculosis (TB). The aim of this study was to develop a Mycobacterium tuberculosis specific skin test reagent, without false positive results due to Bacillus Calmette-Guerin (BCG) vaccination using recombinant antigens. Proteins in PPD IC-65 were analyzed by tandem mass spectrometry and compared to proteins in M. tuberculosis culture filtrate; 54 proteins were found in common. Top candidates MPT64, ESAT 6, and CFP 10 were overexpressed in Escherichia coli expression strains and purified as recombinant proteins. To formulate optimal immunodiagnostic PPD cocktails, the antigens were evaluated by skin testing guinea pigs sensitized with M. tuberculosis H37Rv and BCG. For single antigens and a cocktail mixture of these antigens, best results were obtained using 3 μg/0.1 ml, equivalent to 105 TU (tuberculin units). Each animal was simultaneously tested with PPD IC-65, 2 TU/0.1 ml, as reference. Reactivity of the multi-antigen cocktail was greater than that of any single antigen. The skin test results were between 34.3 and 76.6 per cent the level of reactivity compared to that of the reference when single antigens were tested and 124 per cent the level of reactivity compared to the reference for the multi-antigen cocktail. Our results showed that this specific cocktail could represent a potential candidate for a new skin diagnostic test for TB.
International Nuclear Information System (INIS)
Pastore, G.; Dentico, P.; Angarano, G.; Schiraldi, O.; Zanetti, A.R.; Ferroni, P.
1980-01-01
A radioimmunoassay for hepatitis e antigen (HBeAg) and antibody to e (anti-HBe) was developed and sera of 71 asymptomatic chronic carriers of hepatitis B surface antigen (HBsAg), in 44 of whom liver biopsy was obtained, were tested. In addition, testing for Dane particle associated DNA polymerase activity was performed in all sera. HBeAg was detected in 14 subjects (19.7%) and anti-HBe in 46 (64.8%). The highest proportion of HBeAg positivity (40%) was found among carriers with histological evidence of chronic hepatitis, whereas anti-HBe was present in 80% of carriers with normal liver histology, in 58% of carriers with non-specific reactive hepatitis and in 60% of carriers with chronic liver lesions. DNA polymerase activity was present in 92.8% of sera positive for HBeAg, in 13% of sera positive for anti HBe, and in 9% of sera negative for both markers. Our results demonstrate that not all HBsAg carriers reactive to HBeAg show evidence of chronic hepatitis nor, conversely, that anti-HBe is invariably associated with the healthy carrier state of HBsAg. Finally, circulating Dane particles, as revealed by the presence of serum specific DNA polymerase activity, may also be present in anti-HBe positive sera other than those of some HBsAg carriers lacking both HBeAg and anti-HBe. (orig.) [de
International Nuclear Information System (INIS)
Mackey, L.; Perrin, L.; Leemans, E.; Lambert, P.H.
1980-01-01
A method was devised to show that malaria parasites can be detected serologically in infected blood with a high degree of sensitivity. Using a murine malaria model, parasites were demonstrated in a solid-phase radio-immunoassay which measured antibody-binding inhibition. Lysed red blood cells (r.b.c.) were incubated with labelled specific antibody and were then reacted in antigen-coated tubes. The degree of inhibition of antibody binding in the tubes correlated with the level of parasitaemia in the test blood. Using homologous antisera the test detected infection at a level of 1 parasite/million r.b.c.. The specificity of the method was shown by comparison of antibody-binding inhibition in normal and infected r.b.c. and in r.b.c. from non-infected mice with induced reticulocytosis. The sensitivity was shown in vitro in tests of serially diluted blood of high parasitaemia and in vivo for the detection of early infection. The presence of antibody in the test blood did not significantly affect the sensitivity of parasite detection. (author)
Lau, Sai Ming; Chua, Tock H; Sulaiman, Wan-Yussof; Joanne, Sylvia; Lim, Yvonne Ai-Lian; Sekaran, Shamala Devi; Chinna, Karuthan; Venugopalan, Balan; Vythilingam, Indra
2017-03-21
Dengue remains a serious public health problem in Southeast Asia and has increased 37-fold in Malaysia compared to decades ago. New strategies are urgently needed for early detection and control of dengue epidemics. We conducted a two year study in a high human density dengue-endemic urban area in Selangor, where Gravid Ovipositing Sticky (GOS) traps were set up to capture adult Aedes spp. mosquitoes. All Aedes mosquitoes were tested using the NS1 dengue antigen test kit. All dengue cases from the study site notified to the State Health Department were recorded. Weekly microclimatic temperature, relative humidity (RH) and rainfall were monitored. Aedes aegypti was the predominant mosquito (95.6%) caught in GOS traps and 23% (43/187 pools of 5 mosquitoes each) were found to be positive for dengue using the NS1 antigen kit. Confirmed cases of dengue were observed with a lag of one week after positive Ae. aegypti were detected. Aedes aegypti density as analysed by distributed lag non-linear models, will increase lag of 2-3 weeks for temperature increase from 28 to 30 °C; and lag of three weeks for increased rainfall. Proactive strategy is needed for dengue vector surveillance programme. One method would be to use the GOS trap which is simple to setup, cost effective (below USD 1 per trap) and environmental friendly (i.e. use recyclable plastic materials) to capture Ae. aegypti followed by a rapid method of detecting of dengue virus using the NS1 dengue antigen kit. Control measures should be initiated when positive mosquitoes are detected.
Method to conjugate polysaccharide antigens to surfaces for the detection of antibodies.
Boas, Ulrik; Lind, Peter; Riber, Ulla
2014-11-15
A new generic method for the conjugation of lipopolysaccharide (LPS)-derived polysaccharide antigens from gram-negative bacteria has been developed using Salmonella as a model. After removal of lipid A from the LPS by mild acidolysis, the polysaccharide antigen was conjugated to polystyrene microbeads modified with N-alkyl hydroxylamine and N-alkyl-O-methyl hydroxylamine surface groups by incubation of antigen and beads for 16 h at 40 °C without the need for coupling agents. The efficiency of the new method was evaluated by flow cytometry in model samples and serum samples containing antibodies against Salmonella typhimurium and Salmonella dublin. The presented method was compared with a similar method for conjugation of Salmonella polysaccharide antigens to surfaces. Here, the new method showed higher antigen coupling efficiency by detecting low concentrations of antibodies. Furthermore, the polysaccharide-conjugated beads showed preserved bioactivity after 1 year of use. Copyright © 2014 Elsevier Inc. All rights reserved.
Sánchez, B; Monteón, V; Reyes, P A; Espinoza, B
2001-01-01
This report describes two assays for the detection of anti-Trypanosoma cruzi antibodies using Mexican strains of the parasite and the concordance with two assays previously evaluated at the Instituto Nacional de Cardiología Ignacio Chávez in Mexico City. Micro-enzyme-linked immunosorbent assay (ELISA) and Western blot were used for the detection of T. cruzi antibodies with a total extract of epimastigote from Ninoa and Queretaro, which are Mexican strains of T. cruzi. To standardize these methods, a total of 246 serum samples was used. In addition, sera from six confirmed Mexican chronic individuals in the asymptomatic phase were also used for comparison with the Argentinean antigen. ELISA was 100% specific in that no false positive results were found with sera of both healthy individuals and non-Chagasic cardiopaths. Sera from individuals infected with Leishmania sp. showed approximately 16% of cross-reaction with ELISA. The test showed a positive predictive value of 90% and a negative predictive value of 100%. Western blot was also a highly sensitive test for detecting chronic Chagasic symptomatic patients from Mexico because no false negative results were obtained. Furthermore, it was possible to use Western blot to detect seven immunodominant antigens of approximately 30, 32, 40, 42, 65, 70, and 83 kDa. Concordance with two previous standardized tests at the Instituto Nacional de Cardiología showed a Kappa index of 0.96, indicating high concordance between the results obtained at these two laboratories. Finally, ELISA using Ninoa antigen extract was more sensitive than ELISA with an Argentinean extract, which failed to detect individuals in the chronic asymptomatic phase (undetermined phase) of infection. This study indicates that ELISA and Western blot using Ninoa and/or Queretaro extracts of T. cruzi as antigens are useful tools in the detection of individuals who have been exposed to T. cruzi both in the undetermined/asymptomatic and symptomatic phases
Directory of Open Access Journals (Sweden)
Sarwitri Endah Estuningsih
2006-10-01
Full Text Available Capture-ELISA assay is a diagnosis for antigen detection in the serum or faeces using polyclonal or monoclonal antibodies. The purpose of this study was to determine the sensitivity and specificity of capture-ELISA assay using polyclonal antibody for diagnosing Fasciola gigantica infection in cattle by detecting antigen in the faeces. In this study, faecal samples and livers were collected from 141 cattle slaughtered in the abattoir in Jakarta. From each animal, liver was processed for liver flukes count and the corresponding faecal sample was analysed for coproantigen. The result of capture-ELISA assay for antigen detection showed that from 85 cattle infected with Fasciola gigantica, 83 had OD > 0.52 (range from 0.52-1.39 and 2 cattle had OD < 0.52 (range from 0.17-0.51. The sensitivity and specificity of the assay were 97.6% and 92.8% respectively. The assay also able to detect 50 ng/ml of antigen in faecal supernatant. It suggests that this assay will have the advantage over the other methods on its ability to detect the active infection. Collection of faeces, rather than serum, will allow a more cost-effective and adaptable method.
Killey, R; Mynors, C; Pearce, R; Nell, A; Prentis, A; Day, M J
2018-01-01
To determine the utility of an in-practice test kit to detect protective serum antibody against canine distemper virus, canine adenovirus and canine parvovirus type 2 in a sample of the UK dog population. Serum samples from 486 dogs, last vaccinated between less than 1 month and 124 months previously, were tested with the VacciCheck™ test kit for protective antibodies against distemper, adenovirus and parvovirus type 2. A high proportion of the dogs tested (93·6%) had protective antibody against all three of the core vaccine antigens: 95·7% of the dogs were seropositive against canine distemper virus, 97·3% against canine adenovirus and 98·5% against canine parvovirus type 2. The small number of dogs that were seronegative for one or more of the antigens (n = 31) may have had waning of previous serum antibody or may have been rare genetic non-responders to that specific antigen. UK veterinarians can be reassured that triennial revaccination of adult dogs with core vaccines provides long-lived protective immunity. In-practice serological test kits are a valuable tool for informing decision-making about canine core revaccination. © 2017 British Small Animal Veterinary Association.
Cross, Robert W.; Boisen, Matthew L.; Millett, Molly M.; Nelson, Diana S.; Oottamasathien, Darin; Hartnett, Jessica N.; Jones, Abigal B.; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shunichiro; Brown, Bethany L.; Pham, Ha; Rowland, Megan M.; Agans, Krystle N.; Geisbert, Joan B.; Heinrich, Megan L.; Kulakosky, Peter C.; Shaffer, Jeffrey G.; Schieffelin, John S.; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M.; Wilson, Russell B.; Saphire, Erica Ollmann; Pitts, Kelly R.; Khan, Sheik Humarr; Grant, Donald S.; Geisbert, Thomas W.; Branco, Luis M.; Garry, Robert F.
2016-01-01
Background. Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013–2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases. Methods. Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance. Results. The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription–polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 105–9.0 × 108 genomes/mL. Conclusions. The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. PMID:27587634
Directory of Open Access Journals (Sweden)
Becky L Rivoire
Full Text Available True incidence of leprosy and its impact on transmission will not be understood until a tool is available to measure pre-symptomatic infection. Diagnosis of leprosy disease is currently based on clinical symptoms, which on average take 3-10 years to manifest. The fact that incidence, as defined by new case detection, equates with prevalence, i.e., registered cases, suggests that the cycle of transmission has not been fully intercepted by implementation of multiple drug therapy. This is supported by a high incidence of childhood leprosy. Epidemiological screening for pre-symptomatic leprosy in large endemic populations is required to facilitate targeted chemoprophylactic interventions. Such a test must be sensitive, specific, simple to administer, cost-effective, and easy to interpret. The intradermal skin test method that measures cell-mediated immunity was explored as the best option. Prior knowledge on skin testing of healthy subjects and leprosy patients with whole or partially fractionated Mycobacterium leprae bacilli, such as Lepromin or the Rees' or Convit' antigens, has established an acceptable safety and potency profile of these antigens. These data, along with immunoreactivity data, laid the foundation for two new leprosy skin test antigens, MLSA-LAM (M. leprae soluble antigen devoid of mycobacterial lipoglycans, primarily lipoarabinomannan and MLCwA (M. leprae cell wall antigens. In the absence of commercial interest, the challenge was to develop these antigens under current good manufacturing practices in an acceptable local pilot facility and submit an Investigational New Drug to the Food and Drug Administration to allow a first-in-human phase I clinical trial.
Rivoire, Becky L; TerLouw, Stephen; Groathouse, Nathan A; Brennan, Patrick J
2014-01-01
True incidence of leprosy and its impact on transmission will not be understood until a tool is available to measure pre-symptomatic infection. Diagnosis of leprosy disease is currently based on clinical symptoms, which on average take 3-10 years to manifest. The fact that incidence, as defined by new case detection, equates with prevalence, i.e., registered cases, suggests that the cycle of transmission has not been fully intercepted by implementation of multiple drug therapy. This is supported by a high incidence of childhood leprosy. Epidemiological screening for pre-symptomatic leprosy in large endemic populations is required to facilitate targeted chemoprophylactic interventions. Such a test must be sensitive, specific, simple to administer, cost-effective, and easy to interpret. The intradermal skin test method that measures cell-mediated immunity was explored as the best option. Prior knowledge on skin testing of healthy subjects and leprosy patients with whole or partially fractionated Mycobacterium leprae bacilli, such as Lepromin or the Rees' or Convit' antigens, has established an acceptable safety and potency profile of these antigens. These data, along with immunoreactivity data, laid the foundation for two new leprosy skin test antigens, MLSA-LAM (M. leprae soluble antigen devoid of mycobacterial lipoglycans, primarily lipoarabinomannan) and MLCwA (M. leprae cell wall antigens). In the absence of commercial interest, the challenge was to develop these antigens under current good manufacturing practices in an acceptable local pilot facility and submit an Investigational New Drug to the Food and Drug Administration to allow a first-in-human phase I clinical trial.
Sakuma, Shinji; Yu, James Y H; Quang, Timothy; Hiwatari, Ken-Ichiro; Kumagai, Hironori; Kao, Stephanie; Holt, Alex; Erskind, Jalysa; McClure, Richard; Siuta, Michael; Kitamura, Tokio; Tobita, Etsuo; Koike, Seiji; Wilson, Kevin; Richards-Kortum, Rebecca; Liu, Eric; Washington, Kay; Omary, Reed; Gore, John C; Pham, Wellington
2015-03-01
Thomsen-Friedenreich (TF) antigen belongs to the mucin-type tumor-associated carbohydrate antigen. Notably, TF antigen is overexpressed in colorectal cancer (CRC) but is rarely expressed in normal colonic tissue. Increased TF antigen expression is associated with tumor invasion and metastasis. In this study, we sought to validate a novel nanobeacon for imaging TF-associated CRC in a preclinical animal model. We developed and characterized the nanobeacon for use with fluorescence colonoscopy. In vivo imaging was performed on an orthotopic rat model of CRC. Both white light and fluorescence colonoscopy methods were utilized to establish the ratio-imaging index for the probe. The nanobeacon exhibited specificity for TF-associated cancer. Fluorescence colonoscopy using the probe can detect lesions at the stage which is not readily confirmed by conventional visualization methods. Further, the probe can report the dynamic change of TF expression as tumor regresses during chemotherapy. Data from this study suggests that fluorescence colonoscopy can improve early CRC detection. Supplemented by the established ratio-imaging index, the probe can be used not only for early detection, but also for reporting tumor response during chemotherapy. Furthermore, since the data obtained through in vivo imaging confirmed that the probe was not absorbed by the colonic mucosa, no registered toxicity is associated with this nanobeacon. Taken together, these data demonstrate the potential of this novel probe for imaging TF antigen as a biomarker for the early detection and prediction of the progression of CRC at the molecular level. © 2014 UICC.
Characterization of Antigen-Specific B Cells Using Nominal Antigen-Coated Flow-Beads
Akl, Ahmed; Lepetit, Maud; Crochette, Romain; Giral, Magali; Lepourry, Julie; Pallier, Annaick; Castagnet, Stéphanie; Dugast, Emilie; Guillot-Gueguen, Cécile; Jacq-Foucher, Marylène; Saulquin, Xavier; Cesbron, Anne; Laplaud, David; Nicot, Arnaud; Brouard, Sophie; Soulillou, Jean-Paul
2013-01-01
In order to characterize the reactivity of B cells against nominal antigens, a method based on the coupling of antigens onto the surface of fluorescent core polystyrene beads was developed. We first demonstrate that murine B cells with a human MOG-specific BCR are able to interact with MOG-coated beads and do not recognize beads coated with human albumin or pp65. B cells purified from human healthy volunteer blood or immunized individuals were tested for their ability to interact with various nominal antigens, including viral, vaccine, self and alloantigens, chosen for their usefulness in studying a variety of pathological processes. A substantial amount of B cells binding self-antigen MOG-coated beads can be detected in normal blood. Furthermore, greater frequencies of B cell against anti-Tetanic Toxin or anti-EBNA1 were observed in primed individuals. This method can reveal increased frequencies of anti-HLA committed B cells in patients with circulating anti-HLA antibodies compared to unsensitized patients and normal individuals. Of interest, those specific CD19 cells were preferentially identified within CD27−IgD+ (i-e naïve) subset. These observations suggest that a broad range of medical situations could benefit from a tool that allows the detection, the quantification and the characterization of antigen-specific blood B cells. PMID:24386360
International Nuclear Information System (INIS)
Nicholson, S.; Efandis, T.; Gust, I.
1991-01-01
A study was performed to assess the sensitivity and specificity of the amerlite monoclonal immunoassay for detection of hepatitis B surface antigen (HBsAG) by comparison with the Abbott Ausria II radioimmunoassay (RI). Serial bleeds from 34 patients with acute or chronic hepatitis B were tested by both assays. The Abbott Ausria II assay detected HBsAG longer than the Amersham Amerlite assay on two occasions and earlier on one occasion. Twelve patients with low HBsAg positive results (confirmed by Ausria II) were tested by the Amerlite assay, four were repeatably positive, five repeatably negative and three gave borderline results (which on repeat testing were negative). A similar trend was seen when a panel of sera containing known concentrations of HBsAG was tested. Replicate testing of 10 specimens eight times showed very good reproducibility by the Amerlite assay. Overall, the specificity of both assays was comparable, however differences in sensitivity were observed. 3 tabs
Indirect solid-phase immunosorbent assay for detection of arenavirus antigens and antibodies
Energy Technology Data Exchange (ETDEWEB)
Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A [Institute of Poliomyelitis anU Viral Encephalities of the U.S.S.R. Academy of Medical Sciences, Moscow
1984-05-01
Indirect enzyme-linked immunosorbent assay (ELISA) and solid phase radioimmunoassay (SPRIA) using either enti-human or anti-mouse IgG labelled with horseradish peroxidase and /sup 125/I, respectively, were developed for the detection of Junin, Machupo, Tacaribe, Amapari, Tamiami, Lassa and LCM arenaviruses. Both methods allow high sensitivity detection of arenavirus antigens and antibodies.
Directory of Open Access Journals (Sweden)
Marinka Drobnič-Košorok
2002-01-01
Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.
Maltha, Jessica; Guiraud, Issa; Lompo, Palpouguini; Kaboré, Bérenger; Gillet, Philippe; Van Geet, Chris; Tinto, Halidou; Jacobs, Jan
2014-01-13
In most sub-Saharan African countries malaria rapid diagnostic tests (RDTs) are now used for the diagnosis of malaria. Most RDTs used detect Plasmodium falciparum histidine-rich protein-2 (PfHRP2), though P. falciparum-specific parasite lactate dehydrogenase (Pf-pLDH)-detecting RDTs may have advantages over PfHRP2-detecting RDTs. Only few data are available on the use of RDTs in severe illness and the present study compared Pf-pLDH to PfHRP2-detection. Hospitalized children aged one month to 14 years presenting with fever or severe illness were included over one year. Venous blood samples were drawn for malaria diagnosis (microscopy and RDT), culture and complete blood count. Leftovers were stored at -80 °C and used for additional RDT analysis and PCR. An RDT targeting both PfHRP2 and Pf-pLDH was performed on all samples for direct comparison of diagnostic accuracy with microscopy as reference method. PCR was performed to explore false-positive RDT results. In 376 of 694 (54.2%) included children, malaria was microscopically confirmed. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value were 100.0, 70.9, 69.4 and 100.0%, respectively for PfHRP2-detection and 98.7, 94.0, 91.6 and 99.1%, respectively for Pf-pLDH-detection. Specificity and PPV were significantly lower for PfHRP2-detection (p <0.001). For both detection antigens, specificity was lowest for children one to five years and in the rainy season. PPV for both antigens was highest in the rainy season, because of higher malaria prevalence. False positive PfHRP2 results were associated with prior anti-malarial treatment and positive PCR results (98/114 (86.0%) samples tested). Among children presenting with severe febrile illness in a seasonal hyperendemic malaria transmission area, the present study observed similar sensitivity but lower specificity and PPV of PfHRP2 compared to Pf-pLDH-detection. Further studies should assess the diagnostic accuracy and safety of an
Suin, Vanessa; Nazé, Florence; Francart, Aurélie; Lamoral, Sophie; De Craeye, Stéphane; Kalai, Michael; Van Gucht, Steven
2014-01-01
A generic two-step lyssavirus real-time reverse transcriptase polymerase chain reaction (qRT-PCR), based on a nested PCR strategy, was validated for the detection of different lyssavirus species. Primers with 17 to 30% of degenerate bases were used in both consecutive steps. The assay could accurately detect RABV, LBV, MOKV, DUVV, EBLV-1, EBLV-2, and ABLV. In silico sequence alignment showed a functional match with the remaining lyssavirus species. The diagnostic specificity was 100% and the sensitivity proved to be superior to that of the fluorescent antigen test. The limit of detection was ≤ 1 50% tissue culture infectious dose. The related vesicular stomatitis virus was not recognized, confirming the selectivity for lyssaviruses. The assay was applied to follow the evolution of rabies virus infection in the brain of mice from 0 to 10 days after intranasal inoculation. The obtained RNA curve corresponded well with the curves obtained by a one-step monospecific RABV-qRT-PCR, the fluorescent antigen test, and virus titration. Despite the presence of degenerate bases, the assay proved to be highly sensitive, specific, and reproducible.
THE SEARCH OF OPTIMAL COMBINATION OF ANTIGENS FOR SEROLOGICAL DIAGNOSTICS OF TUBERCULOSIS
Directory of Open Access Journals (Sweden)
E. V. Vasilyeva
2013-01-01
Full Text Available Abstract. The four chimeric recombinant antigens CBD-CFP10, CBD-ESAT6, ESAT6-CFP10 and CBD-P38 contained aminoacid sequences of full-size proteins ESAT6, CFP10 and matured protein P38 of M. tuberculosis, joined with aminoacid sequences of cellulose bind domain of endogluconase A (CBD from Cellumonas fimi have been obtained by gene engineering methods. Recombinant proteins were purified by affine chromatography in column with Ni-NTA-sepharose 6В-CL and as PPDN-3 were used for detection of their antigenic activity in indirect ELISA for TB serological diagnostics. The sera from patients with lung tuberculosis (n = 321, from persons who had professional contacts with TB patients (n = 42, from healthy blood donors (n = 366 and from patients with lung diseases of non-TB etiology were tested. It was detected that there was positive correlation between antibodies level for all studied antigens compared by pair. It has been demonstrated that although antigens were different by antigenic and immunobiological characteristics they add each other in the content of antigenic diagnostics compositions. Thus, all these antigens can be used in the test kits for serological diagnostics of TB. Using of these antigens will allow to detect persons infected by TB and patients with active tuberculosis.
Directory of Open Access Journals (Sweden)
Simonetti SRR
2002-01-01
Full Text Available Hepatic viscerotomy of paraffin-preserved old specimens, collected in the period from 1934 to 1967, were analyzed by immunohistochemical assays to detect hepatitis B, hepatitis D, dengue and yellow fever virus antigens. The material belongs to the Yellow Fever Collection, Department of Pathology, Instituto Oswaldo Cruz, Rio de Janeiro, Brazil and the cases were diagnosed at that time according to clinical aspects and histopathological findings reporting viral hepatitis, yellow fever, focal necrosis and hepatic atrophy. From the 79 specimens, 69 were collected at the Labrea Region and the other 10 in different other localities in the Amazon Region. The five micra thick histological slices were analyzed for the presence of hepatitis B surface antigen (HBsAg and hepatitis B core antigen (HBcAg by immunoperoxidase technique. An immunofluorescence assay was applied to the detection of hepatitis D, yellow fever and dengue virus antigens. Nine (11.4% histological samples were HBsAg reactive and 5 (6.3% were HBcAg reactive. The oldest reactive sample was from 1934. Viral antigens related to the other pathologies were not detected in this study. Our results confirm that the methodology described may be used to elucidate the aetiology of hepatitis diseases even after a long time of conservation of the specimens.
Detection of Rabies Antigen in the Brain Tissues of Apparetly ...
African Journals Online (AJOL)
Rabies is a serious public health hazard and recently outbreaks of the disease have been reported in three local government areas in Cross River State. Detection of rabies antigen in the brain tissues of apparently healthy dogs indicates the presence of rabies virus and this is a significant factor in the transmission and ...
Directory of Open Access Journals (Sweden)
Ali Amini
2017-11-01
Full Text Available Abstract Background Chronic Hepatitis B Virus (HBV infection is characterised by the persistence of hepatitis B surface antigen (HBsAg. Expanding HBV diagnosis and treatment programmes into low resource settings will require high quality but inexpensive rapid diagnostic tests (RDTs in addition to laboratory-based enzyme immunoassays (EIAs to detect HBsAg. The purpose of this review is to assess the clinical accuracy of available diagnostic tests to detect HBsAg to inform recommendations on testing strategies in 2017 WHO hepatitis testing guidelines. Methods The systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA guidelines using 9 databases. Two reviewers independently extracted data according to a pre-specified plan and evaluated study quality. Meta-analysis was performed. HBsAg diagnostic accuracy of rapid diagnostic tests (RDTs was compared to enzyme immunoassay (EIA and nucleic-acid test (NAT reference standards. Subanalyses were performed to determine accuracy among brands, HIV-status and specimen type. Results Of the 40 studies that met the inclusion criteria, 33 compared RDTs and/or EIAs against EIAs and 7 against NATs as reference standards. Thirty studies assessed diagnostic accuracy of 33 brands of RDTs in 23,716 individuals from 23 countries using EIA as the reference standard. The pooled sensitivity and specificity were 90.0% (95% CI: 89.1, 90.8 and 99.5% (95% CI: 99.4, 99.5 respectively, but accuracy varied widely among brands. Accuracy did not differ significantly whether serum, plasma, venous or capillary whole blood was used. Pooled sensitivity of RDTs in 5 studies of HIV-positive persons was lower at 72.3% (95% CI: 67.9, 76.4 compared to that in HIV-negative persons, but specificity remained high. Five studies evaluated 8 EIAs against a chemiluminescence immunoassay reference standard with a pooled sensitivity and specificity of 88.9% (95% CI: 87.0, 90.6 and
Cross, Robert W; Boisen, Matthew L; Millett, Molly M; Nelson, Diana S; Oottamasathien, Darin; Hartnett, Jessica N; Jones, Abigal B; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A; Fusco, Marnie L; Abelson, Dafna M; Oda, Shunichiro; Brown, Bethany L; Pham, Ha; Rowland, Megan M; Agans, Krystle N; Geisbert, Joan B; Heinrich, Megan L; Kulakosky, Peter C; Shaffer, Jeffrey G; Schieffelin, John S; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M; Wilson, Russell B; Saphire, Erica Ollmann; Pitts, Kelly R; Khan, Sheik Humarr; Grant, Donald S; Geisbert, Thomas W; Branco, Luis M; Garry, Robert F
2016-10-15
Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013-2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases. Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance. The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription-polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 10 5 -9.0 × 10 8 genomes/mL. The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Energy Technology Data Exchange (ETDEWEB)
Zhuang, H [Beijing Medical College (China); Coulepis, A G; Gust, I D [Fairfield Hospital for Communicable Diseases, Melbourne (Australia)
1972-08-01
The sensitivity and specificity of two commercially available reverse passive haemagglutination tests (Hepatest and Raphadex B) for the detection of hepatitis B surface antigen, were compared with the most widely used radioimmunoassay (Ausria II-125). A selected group of 282 sera were tested: these included the Australian hepatitis B reference panel, and a batch of 257 sera collected from patients with acute hepatitis B, chronic carriers of hepatitis B surface antigen and two populations in which hepatitis B virus infection is known to be endemic. The two reverse passive haemagglutination techniques were of comparable sensitivity but slightly less sensitive than radioimmunoassay. While radioimmunoassay still remains the test of choice for blood transfusion services, the reverse passive haemagglutination techniques are of great value for smaller laboratories and for field studies because of their longer shelf life, the absence of radioactive reagents and the lack of need to acquire a gammacounter.
Detection of Puumala hantavirus antigen in human intestine during acute hantavirus infection.
Directory of Open Access Journals (Sweden)
Joerg Latus
Full Text Available BACKGROUND: Puumala virus (PUUV is the most important hantavirus species in Central Europe. Nephropathia epidemica (NE, caused by PUUV, is characterized by acute renal injury (AKI with thrombocytopenia and frequently gastrointestinal symptoms. METHODS: 456 patients with serologically and clinically confirmed NE were investigated at time of follow-up in a single clinic. The course of the NE was investigated using medical reports. We identified patients who had endoscopy with intestinal biopsy during acute phase of NE. Histopathological, immunohistochemical and molecular analyses of the biopsies were performed. RESULTS: Thirteen patients underwent colonoscopy or gastroscopy for abdominal pain, diarrhea, nausea and vomiting during acute phase of NE. Immunohistochemistry (IHC revealed PUUV nucleocapsid antigen in 11 biopsies from 8 patients; 14 biopsies from 5 patients were negative for PUUV nucleocapsid antigen. IHC localized PUUV nucleocapsid antigen in endothelial cells of capillaries or larger vessels in the lamina propria. Rate of AKI was not higher and severity of AKI was not different in the PUUV-positive compared to the PUUV-negative group. All IHC positive biopsies were positive for PUUV RNA using RT-PCR. Phylogenetic reconstruction revealed clustering of all PUUV strains from this study with viruses previously detected from the South-West of Germany. Long-term outcome was favorable in both groups. CONCLUSIONS: In patients with NE, PUUV nucleocapsid antigen and PUUV RNA was detected frequently in the intestine. This finding could explain frequent GI-symptoms in NE patients, thus demonstration of a more generalized PUUV infection. The RT-PCR was an effective and sensitive method to detect PUUV RNA in FFPE tissues. Therefore, it can be used as a diagnostic and phylogenetic approach also for archival materials. AKI was not more often present in patients with PUUV-positive IHC. This last finding should be investigated in larger numbers of
An indirect antibody assay using haptenated antigen and 125I-labelled anti-hapten antibody
International Nuclear Information System (INIS)
Aalberse, R.C.; Amsterdam Univ.
1978-01-01
Hapten (trinitrophenyl) was coupled to antigen (ovalbumin). The haptenated antigen was bound by anti-ovalbumin antibody and binding was quantitated with 125 I-labelled anti-hapten antibodies. Thus, with a single radioactive reagent, antibodies against a variety of antigens can be detected while the problems inherent in a labelled antiglobulin binding test are avoided. In the ovalbumin system, the haptenated antigen binding test proved to be approximately 20 times as sensitive as the iodinated ovalbumin binding test
Carrio, Roberto; Zhang, Ge; Drake, Donald R; Schanen, Brian C
2018-05-07
Although a variety of assays have been used to examine T cell responses in vitro, standardized ex vivo detection of antigen-specific CD4 + T cells from human circulatory PBMCs remains constrained by low-dimensional characterization outputs and the need for polyclonal, mitogen-induced expansion methods to generate detectable response signals. To overcome these limitations, we developed a novel methodology utilizing antigen-pulsed autologous human dendritic target cells in a rapid and sensitive assay to accurately enumerate antigen-specific CD4 + T cell precursor frequency by multiparametric flow cytometry. With this approach, we demonstrate the ability to reproducibly quantitate poly-functional T cell responses following both primary and recall antigenic stimulation. Furthermore, this approach enables more comprehensive phenotypic profiling of circulating antigen-specific CD4 + T cells, providing valuable insights into the pre-existing polarization of antigen-specific T cells in humans. Combined, this approach permits sensitive and detailed ex vivo detection of antigen-specific CD4 + T cells delivering an important tool for advancing vaccine, immune-oncology and other therapeutic studies.
Carcinoembryonic Antigen Level in Liver Disease
Energy Technology Data Exchange (ETDEWEB)
Choi, Kyoo Ok; Kim, Ki Whang; Park, Chang Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)
1978-09-15
Carcinoembryonic antigen was initially known as tumor specific antigen and had a potential diagnostic value in the detection of digestive tract malignancies. However, subsequent studies showed CEA and CEA-like antigen present in benign disease, particularly in liver. We had collected sera from 58 patients who had liver scan and later were diagnosed clinically and histologically as liver disease. We estimated CEA values and correlations were made with liver function tests in liver cirrhosis cases. The results: 1) The raised plasma carcinoembryonic antigen level were found in 13 (68.4%) of 19 patients cirrhosis, 5 (27.8%) of 18 patients in hepatoma, 5 (71%) of 7 patients in chronic active hepatitis, all 3 patients in liver abscesses, 2 (66.7%) of 3 patients in liver abscesses, 2 (66.7%) of 3 patients in obstructive biliary disease and none in each one patient of traumatic liver hematoma, subphrenic abscess and clonorchiasis. 2) There is no linear correlation between carcinoembryonic antigen level and liver function tests including serum bilirubin, alkaline phosphatase, SGOT and prothrombin time in liver patients.
Carcinoembryonic Antigen Level in Liver Disease
International Nuclear Information System (INIS)
Choi, Kyoo Ok; Kim, Ki Whang; Park, Chang Yun
1978-01-01
Carcinoembryonic antigen was initially known as tumor specific antigen and had a potential diagnostic value in the detection of digestive tract malignancies. However, subsequent studies showed CEA and CEA-like antigen present in benign disease, particularly in liver. We had collected sera from 58 patients who had liver scan and later were diagnosed clinically and histologically as liver disease. We estimated CEA values and correlations were made with liver function tests in liver cirrhosis cases. The results: 1) The raised plasma carcinoembryonic antigen level were found in 13 (68.4%) of 19 patients cirrhosis, 5 (27.8%) of 18 patients in hepatoma, 5 (71%) of 7 patients in chronic active hepatitis, all 3 patients in liver abscesses, 2 (66.7%) of 3 patients in liver abscesses, 2 (66.7%) of 3 patients in obstructive biliary disease and none in each one patient of traumatic liver hematoma, subphrenic abscess and clonorchiasis. 2) There is no linear correlation between carcinoembryonic antigen level and liver function tests including serum bilirubin, alkaline phosphatase, SGOT and prothrombin time in liver patients.
Follow-up of neurocysticercosis patients after treatment using an antigen detection ELISA
Directory of Open Access Journals (Sweden)
Nguekam
2003-03-01
Full Text Available Seven patients with active neurocysticercosis (NCC received an eight days treatment with albendazole and were followed up using computed tomography (CT-scan and a monoclonal antibody based ELISA for the detection of circulating antigen (Ag-ELISA. Only three patients were cured as was shown by CT-scan and by the disappearance of circulating antigens one month after treatment. After a second course of albendazole therapy, two other patients became seronegative. CT-scan showed the disappearance of viable cysts in all persons who became seronegative whereas patients who were not cured remained seropositive. These preliminary results show that this Ag-ELISA is a promising technique for monitoring the success of treatment of NCC patients because of the excellent correlation between the presence of circulating antigens and of viable brain cysts.
Halpern, Micah D.; Molins, Claudia R.; Schriefer, Martin
2014-01-01
A serology-based tiered approach has, to date, provided the most effective means of laboratory confirmation of clinically suspected cases of Lyme disease, but it lacks sensitivity in the early stages of disease and is often dependent on subjectively scored immunoblots. We recently demonstrated the use of immuno-PCR (iPCR) for detecting Borrelia burgdorferi antibodies in patient serum samples that were positive for Lyme disease. To better understand the performance of the Lyme disease iPCR assay, the repeatability and variability of the background of the assay across samples from a healthy population (n = 36) were analyzed. Both of these parameters were found to have coefficients of variation of Lyme disease patient serum samples (n = 12) demonstrated a strong correlation with that of 2-tier testing. Furthermore, a simplified iPCR approach using a single hybrid antigen and detecting only IgG antibodies confirmed the 2-tier diagnosis in the Lyme disease patient serum samples (n = 12). Validation of the hybrid antigen IgG iPCR assay using a blinded panel of Lyme disease and non-Lyme disease patient serum samples (n = 92) resulted in a sensitivity of 69% (95% confidence interval [CI], 50% to 84%), compared to that of the 2-tier analysis at 59% (95% CI, 41% to 76%), and a specificity of 98% (95% CI, 91% to 100%) compared to that of the 2-tier analysis at 97% (95% CI, 88% to 100%). A single-tier hybrid antigen iPCR assay has the potential to be an improved method for detecting host-generated antibodies against B. burgdorferi. PMID:24899074
Two types of nanoparticle-based bio-barcode amplification assays to detect HIV-1 p24 antigen
Directory of Open Access Journals (Sweden)
Dong Huahuang
2012-08-01
Full Text Available Abstract Background HIV-1 p24 antigen is a major viral component of human immunodeficiency virus type 1 (HIV-1 which can be used to identify persons in the early stage of infection and transmission of HIV-1 from infected mothers to infants. The detection of p24 is usually accomplished by using an enzyme-linked immunosorbent assay (ELISA with low detection sensitivity. Here we report the use of two bio-barcode amplification (BCA assays combined with polymerase chain reaction (PCR and gel electrophoresis to quantify HIV-1 p24 antigen. Method A pair of anti-p24 monoclonal antibodies (mAbs were used in BCA assays to capture HIV-1 p24 antigen in a sandwich format and allowed for the quantitative measurement of captured p24 using PCR and gel electrophoresis. The first 1 G12 mAb was coated on microplate wells or magnetic microparticles (MMPs to capture free p24 antigens. Captured p24 in turn captured 1D4 mAb coated gold nanoparticle probes (GNPs containing double-stranded DNA oligonucleotides. One strand of the oligonucleotides was covalently immobilized whereas the unbound complimentary bio-barcode DNA strand could be released upon heating. The released bio-barcode DNA was amplified by PCR, electrophoresed in agarose gel and quantified. Results The in-house ELISA assay was found to quantify p24 antigen with a limit of detection (LOD of 1,000 pg/ml and a linear range between 3,000 and 100,000 pg/ml. In contrast, the BCA-based microplate method yielded an LOD of 1 pg/ml and a linear detection range from 1 to 10,000 pg/ml. The BCA-based MMP method yielded an LOD of 0.1 pg/ml and a linear detection range from 0.1 to 1,000 pg/ml. Conclusions When combined with PCR and simple gel electrophoresis, BCA-based microplate and MMPs assays can be used to quantify HIV-1 p24 antigen. These methods are 3–4 orders of magnitude more sensitive than our in-house ELISA-based assay and may provide a useful approach to detect p24 in patients newly infected
A TeGM6-4r antigen-based immunochromatographic test (ICT) for animal trypanosomosis.
Nguyen, Thu-Thuy; Ruttayaporn, Ngasaman; Goto, Yasuyuki; Kawazu, Shin-ichiro; Sakurai, Tatsuya; Inoue, Noboru
2015-11-01
Animal trypanosomosis is a disease that is distributed worldwide which results in huge economic losses due to reduced animal productivity. Endemic regions are often located in the countryside where laboratory diagnosis is costly or inaccessible. The establishment of simple, effective, and accurate field tests is therefore of great interest to the farming and veterinary sectors. Our study aimed to develop a simple, rapid, and sensitive immunochromatographic test (ICT) for animal trypanosomosis utilizing the recombinant tandem repeat antigen TeGM6-4r, which is conserved amongst salivarian trypanosome species. In the specificity analysis, TeGM6-4r/ICT detected all of Trypanosoma evansi-positive controls from experimentally infected water buffaloes. As expected, uninfected controls tested negative. All sera samples collected from Tanzanian and Ugandan cattle that were Trypanosoma congolense- and/or Trypanosoma vivax-positive by microscopic examination of the buffy coat were found to be positive by the newly developed TeGM6-4r/ICT, which was comparable to results from TeGM6-4r/ELISA (kappa coefficient [κ] = 0.78). TeGM6/ICT also showed substantial agreement with ELISA using Trypanosoma brucei brucei (κ = 0.64) and T. congolense (κ = 0.72) crude antigen, suggesting the high potential of TeGM6-4r/ICT as a field diagnostic test, both for research purposes and on-site diagnosis of animal trypanosomosis.
O'Dell, K J; Volk, R J; Cass, A R; Spann, S J
1999-09-01
The benefits of early detection of prostate cancer are uncertain, and the American College of Physicians and the American Academy of Family Physicians recommend individual decision making in prostate cancer screening. This study reports the knowledge of male primary care patients about prostate cancer and prostate-specific antigen (PSA) testing and examines how that knowledge is related to PSA testing, preferences for testing in the future, and desire for involvement in physician-patient decision making. The sample included 160 men aged 45 to 70 years with no history of prostate cancer who presented for care at a university-based family medicine clinic. Before scheduled office visits, patients completed a questionnaire developed for this study that included a 10-question measure of prostate cancer knowledge, the Deber-Kraestchmer Problem-Solving Decision-Making Scale, sociodemographic indicators, and questions on PSA testing. In general, patients who were college graduates were more knowledgeable about prostate cancer and early detection than those with a high school education or less. Aside from college graduates, most patients could not identify the principle advantages and disadvantages of PSA testing. Patients indicating previous or future plans for PSA testing demonstrated greater knowledge than other patients. Desire for involvement in decision making varied by patient education but was not related to past PSA testing. Patients lack knowledge about prostate cancer and early detection. This knowledge deficit may impede the early detection of prostate cancer and is a barrier to making an informed decision about undergoing PSA testing.
Detection of HCV core antigen and its diagnostic significance
Directory of Open Access Journals (Sweden)
YANG Jie
2013-02-01
Full Text Available ObjectiveTo compare the abilities of the hepatitis C virus (HCV core antigen (cAg test and the HCV RNA assay for confirming anti-HCV presence in order to determine the clinical utility of the HCV-cAg as an alternative or confirmatory diagnostic tool. MethodsSerum samples collected from 158 patients diagnosed with HCV infection were subjected to the enzyme-linked immunosorbent assay-based HCV-cAg test. The optical density (OD measured values were used to calculate the ratio of specimen absorbance to the cutoff value (S/CO. Simultaneously, the serum samples were subjected to PCR-based nucleic acid amplification quantitative fluorescence detection of HCV RNA. ResultsNone of the serum samples had a S/CO value <1 for the HCV-cAg test (100% negative, but all of the samples had a S/CO value >5 (100% positive. The HCV-cAg test sensitivity was 87.05%, specificity was 76.67%, positive predictive value was 9653%, and negative predictive value was 44.23%. As the S/CO value gradually increased, the significantly higher positive coincident rate of the HCV RNA test decreased. The HCV RNA negative coincident rate was significantly higher than that of the HCV-cAg test. HCV-cAg S/CO values between 1 and 2 corresponded to an HCV RNA values between 1.0×103 copies/ml and 1.0×104 copies/ml. The highest S/CO value obtained was 1.992. ConclusionThe HCV-cAg test is comparable to the HCV RNA assay for diagnosing HCV infection.
ter Borg, F.; ten Kate, F. J.; Cuypers, H. T.; Leentvaar-Kuijpers, A.; Oosting, J.; Wertheim-van Dillen, P. M.; Honkoop, P.; Rasch, M. C.; de Man, R. A.; van Hattum, J.; Chamuleau, R. A.; Reesink, H. W.; Jones, E. A.
1998-01-01
BACKGROUND: Hepatitis B surface antigen (HBsAg) and antibodies to hepatitis B e antigen (anti-HBe) commonly coexist, and laboratory tests are often requested to assess histological hepatitis activity. An optimum panel of tests has not been found and the usefulness of hepatitis B virus (HBV) DNA
Directory of Open Access Journals (Sweden)
Vanessa Suin
2014-01-01
Full Text Available A generic two-step lyssavirus real-time reverse transcriptase polymerase chain reaction (qRT-PCR, based on a nested PCR strategy, was validated for the detection of different lyssavirus species. Primers with 17 to 30% of degenerate bases were used in both consecutive steps. The assay could accurately detect RABV, LBV, MOKV, DUVV, EBLV-1, EBLV-2, and ABLV. In silico sequence alignment showed a functional match with the remaining lyssavirus species. The diagnostic specificity was 100% and the sensitivity proved to be superior to that of the fluorescent antigen test. The limit of detection was ≤1 50% tissue culture infectious dose. The related vesicular stomatitis virus was not recognized, confirming the selectivity for lyssaviruses. The assay was applied to follow the evolution of rabies virus infection in the brain of mice from 0 to 10 days after intranasal inoculation. The obtained RNA curve corresponded well with the curves obtained by a one-step monospecific RABV-qRT-PCR, the fluorescent antigen test, and virus titration. Despite the presence of degenerate bases, the assay proved to be highly sensitive, specific, and reproducible.
DiMaio, Michael A; Sahoo, Malaya K; Waggoner, Jesse; Pinsky, Benjamin A
2012-12-01
Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B. Copyright © 2012 Elsevier B.V. All rights reserved.
The end of the road for prostate specific antigen testing? | Nna ...
African Journals Online (AJOL)
Many candidate biomarkers for diagnosis of prostate cancer have been investigated, but prostate‑specific antigen (PSA) testing remains the frontline test for both mass screening and individual clinical testing. Although the PSA test is cost‑effective, analytically reliable, and flexibly high throughput, it has a very weak ...
Maltezou, Helen C; Tsagris, Vasilios; Antoniadou, Anastasia; Galani, Labrini; Douros, Constantinos; Katsarolis, Ioannis; Maragos, Antonios; Raftopoulos, Vasilios; Biskini, Panagiota; Kanellakopoulou, Kyriaki; Fretzayas, Andreas; Papadimitriou, Theodoros; Nicolaidou, Polyxeni; Giamarellou, Helen
2008-12-01
To study the performance of the Becton-Dickinson Link 2 Strep A Rapid Test, a rapid antigen detection test (RADT) for diagnosing streptococcal pharyngitis in children presenting to private offices and to the Pediatric Outpatient Clinic of a university hospital, in relation to clinical criteria (fever, tender anterior cervical lymph nodes, tonsillar exudate and absence of cough), and its impact on antibiotic prescription. Children were enrolled in Group A (enrolment by private-practice paediatricians; diagnosis by clinical picture only), Group B (enrolment by private-practice paediatricians; diagnosis by RADT and culture) or Group C (enrolment by hospital-affiliated paediatricians in the Pediatric Outpatient Clinic; diagnosis by RADT and culture). During a 2 year period, 820 children were enrolled [369 (45%) in Group A, 270 (33%) in Group B and 181 (22%) in Group C]. Streptococcal pharyngitis was diagnosed by RADT and culture in 146 (32.4%) of the 451 tested children. The sensitivity, specificity and positive and negative predictive values of the RADT were 83.1%, 93.3%, 82.4% and 93.6%, respectively. A stepwise increase in the sensitivity of the RADT was noted among children with one, two, three or four clinical criteria (60.9% to 95.8%). Paediatricians without access to laboratory tests were more likely to prescribe antibiotics compared with paediatricians with access to tests (72.2% versus 28.2%, P antibiotics more frequently compared with hospital-affiliated paediatricians (55.7% versus 19.9%, P antibiotic administration. Such a strategy has an important impact on limiting throat culture testing and is associated with reduced antibiotic prescription.
Blixenkrone-Møller, M
1989-09-01
Using an indirect immunofluorescence technique, the distribution of viral antigen in various tissues and blood mononuclear leukocytes was studied in wild mink, either vaccinated with an attenuated vaccine strain of canine distemper virus (CDV) or experimentally inoculated with the virulent Snyder-Hill strain of CDV. Viral antigen was detected in cells of the lymphoid system 6 to 12 days after vaccination. From 2 to 3 days after inoculation with the virulent strain, CDV antigen was demonstrated in cells of the lymphoid system and, during the incubation period, the antigen had spread to the epithelia and brain at days 6 and 12, respectively. In clinical cases of acute fatal canine distemper, the viral antigen was detected in a wide variety of tissues, including the cells of the lymphoid system, epithelial cells of skin, mucous membranes, lung, kidney, and cells of the CNS. The diagnostic importance of CDV antigen detection is discussed on the basis of these findings.
Shen, H D; Lin, W L; Chen, R J; Han, S H
1990-10-01
Cross-reactivity among antigens of 12 genera of air-borne fungi, 13 species of Penicillium, and 5 species of Aspergillus was studied by ELISA using five monoclonal antibodies (MoAbs) against Penicillium notatum. Epitopes recognized by all the five MoAbs were susceptible to treatment of mild periodate oxidation and may therefore be associated with carbohydrates. Furthermore, our results showed that there is cross-reactivity among antigens of Penicillium, Aspergillus, and Eurotium species. By using these MoAbs, cross reactivity was not detected between antigens of Penicillium notatum and antigens of Fusarium solani, Alternaria porri, Cladosporium cladosporoides, Curvularia species, Nigrospora species, Aureobasidium pullulans, Wallemia species, Rhizopus arrhizus, and Candida albicans. Cross-reactivity among antigens of 11 species of Penicillium and 5 species of Aspergillus could be detected by ELISA using one of the five MoAbs (MoAb P15). The fact that there may be cross-reactivity among antigens of closely related fungi species should be considered in the diagnosis and treatment of mold allergic diseases.
Principato, MaryAnn; Njoroge, Joyce M; Perlloni, Andrei; O' Donnell, Michael; Boyle, Thomas; Jones, Robert L
2010-10-01
There is a critical need for qualitative and quantitative methodologies that provide the rapid and accurate detection of food contaminants in complex food matrices. However, the sensitivity of the assay can be affected when antigen-capture is applied to certain foods or beverages that are extremely acidic. This study was undertaken to assess the effects of orange juice and popular carbonated soft drink upon the fidelity of antibody-based antigen-capture assays and to develop simple approaches that could rescue assay performance without the introduction of additional or extensive extraction procedures. We examined the effects of orange juice and a variety of popular carbonated soft drink beverages upon a quantitative Interleukin-2 (IL-2) enzyme-linked immunosorbent assay (ELISA) assay system and a lateral flow device (LFD) adapted for the detection of staphylococcal enterotoxin B (SEB) in foods. Alterations in the performance and sensitivity of the assay were directly attributable to the food matrix, and alterations in pH were especially critical. The results demonstrate that approaches such as an alteration of pH and the use of milk as a blocking agent, either singly or in combination, will partially rescue ELISA performance. The same approaches permit lateral flow to efficiently detect antigen. Practical Application: The authors present ways to rescue an ELISA assay compromised by acidity in beverages and show that either the alteration of pH, or the use of milk as a blocking agent are not always capable of restoring the assay to its intended efficiency. However, the same methods, when employed with lateral flow technology, are rapid and extremely successful.
International Nuclear Information System (INIS)
Babaei, M. H.; Behradkia, P.; Shafii, M.; Movla, M.; Forutan, H.; Najafi, R.
2006-01-01
Prostate is a leading site for the cancer incidence, accounted for 31.0% of new cancer cases in men. Prostate-specific antigen is widely used in the detection and monitoring of the prostate cancer. Currently, immunoassay is used to detect Prostate-specific antigen in human serum. This technique is based on the interaction between antibody and antigen. The varied immunoassay formats and equipment to run the assays allow the users to measure the analytes rapidly, with the flexibility to run a small or a large number of samples. Among different immunoassay methods, immunoradiometric assay is a more sensitive and valuable detection approach. This study has been made in 4 parts: (1) purification of Prostate-specific antigen from seminal fluid; (2) preparation of hybridoma cells which secrete monoclonal antibody (mAb) against Prostate-specific antigen , (3) selection of pair monoclonal antibody among those antibodies, and finally (4) design of an immunoradiometric assay kit and it's quality control . The results of this study were: (1) obtaining a huge amount of Prostate-specific antigen as semi-purified and purified, that is a valuable material for preparation of standard kits; (2) preparation of 8 kinds of monoclonal antibodies; (3) finding 4 pairs of monoclonal antibodies which react with different epitopes on Prostate-specific antigen molecule; and (4) preparation of immunoradiometric assay kit for measuring Prostate-specific antigen concentration in human serum
Energy Technology Data Exchange (ETDEWEB)
Lin, Ying-Ying; Wang, Jun; Liu, Guodong; Wu, Hong; Wai, Chien M.; Lin, Yuehe
2008-06-15
We present a nanoparticle (NP) label/immunochromatographic electrochemical biosensor (IEB) for rapid and sensitive detection of prostate-specific antigen (PSA) in human serum. This IEB integrates the immunochromatographic strip with the electrochemical detector for transducing quantitative signals. The NP label, made of CdSe@ZnS, serves as a signal-amplifier vehicle. A sandwich immunoreaction was performed on the immunochromatographic strip. The captured NP labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane of the test zone. Experimental parameters (e.g., immunoreaction time, the amount of anti-PSA-NP conjugations applied) and electrochemical detection conditions (e.g., preconcentration potential and time) were optimized using this biosensor for PSA detection. The analytical performance of this biosensor was evaluated with serum PSA samples according to the “figure-of-merits” (e.g., dynamic range, reproducibility, and detection limit). The results were validated with enzyme-linked immunosorbent assay (ELISA) and show high consistency. It is found that this biosensor is very sensitive with the detection limit of 0.02 ng/mL PSA and is quite reproducible. This method is rapid, clinically accurate, and less expensive than other diagnosis tools for PSA; therefore, this IEB coupled with a portable electrochemical analyzer shows great promise for simple, sensitive, quantitative point-of-care testing of disease-related protein biomarkers.
DEFF Research Database (Denmark)
Mikkelsen, Heidi; Aagaard, Claus; Nielsen, Søren Saxmose
consisting of undefined antigens with possible cross reactions toward other environmental bacteria. The objective of the study was to optimize the IFN-γ test using different types of novel antigens for stimulation. Fourteen novel antigen candidates were selected for testing, including 4 peptides of the ESAT...
Cornejo, Hernán; Oblitas, Fátima; Cruzado, Sandro; Quispe, William
2010-01-01
Metabolic (excretion/secretion) antigen was obtained from sheep infected with Fasciola hepatica, with a 1005 μg/μL of protein concentration, composed principally by proteins of molecular weight between 1.2 and 170 KDa. Bands of 170, 150, 31, 24, 18-14 and 10 kDa were detected. With this antigen an ELISA test was developed and the cut off was determined in 0.140. We evaluated 33 serums of patient with fascioliasis confirmed by visualization of eggs in feces, 177 serums of persons without fascioliasis from endemic rural areas of Cajamarca and 88 serums of patients with others parasitic and bacterial infections. We found a 97.0% of sensitivity, 96.6 specificity, 78.1% predictive positive value, 99.6 % predictive negative value. In 9/88 serums was found cross reactions. We recommended the implementation and use of this test for the fascioliasis diagnosis.
Directory of Open Access Journals (Sweden)
Luiz Tadeu M. Figueiredo
1988-06-01
Full Text Available A virus antigenic characterization methodology using an indirect method of antibody detection ELISA with virus-infected cultured cells as antigen and a micro virus neutralisation test using EIA (NT-EIA as an aid to reading were used for antigenic characterization of Jatobal (BeAn 423380. Jatobal virus was characterized as a Bunyaviridae, Bunyavirus genus, Simbu serogroup virus. ELISA using infected cultured cells as antigen is a sensitive and reliable method for identification of viruses and has many advantages over conventional antibody capture ELISA's and other tests: it eliminates solid phase coating with virus and laborious antigen preparation; it permits screening of large numbers of virus antisera faster and more easily than by CF, HAI, or plaque reduction NT. ELISA and NT using EIA as an aid to reading can be applicable to viruses which do not produce cytopathogenic effect. Both techniques are applicable to identification of viruses which grow in mosquito cells.A caracterização antigênica do vírus Jatobal (BeAn 423380 foi efetuada utilizando uma técnica de ELISA para deteccão de anticorpos que utiliza culturas celulares infectadas como antígeno e um micro teste de neutralização para vírus que utiliza o método imunoenzimático como auxiliar para a leitura dos resultados (NT-EIA. O vírus Jatobal foi caracterizado como um Bunyaviridae, gênero Bunyavirus, pertencente ao sorogrupo Simbu. A técnica de ELISA, utilizando culturas celulares infectadas como antígeno, trata-se de método sensível e confiável na identificação de agentes virais, possuindo muitas vantagens sobre ELISA convencionais e outros testes: elimina a preparação laboriosa de antígenos para o revestimento em fase sólida; permite que se teste de forma mais rápida e fácil que por CF, HAI e neutralização por redução de plaques um grande número de antisoros de vírus. ELISA e NT-EIA podem ser utilizados para a classificação de vírus que não produzem
Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool
Directory of Open Access Journals (Sweden)
Flávio da Silva Mesquita
2017-05-01
Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.
Radioimmunoassays of hidden viral antigens
International Nuclear Information System (INIS)
Neurath, A.R.; Strick, N.; Baker, L.; Krugman, S.
1982-01-01
Antigens corresponding to infectious agents may be present in biological specimens only in a cryptic form bound to antibodies and, thus, may elude detection. We describe a solid-phase technique for separation of antigens from antibodies. Immune complexes are precipitated from serum by polyethylene glycol, dissociated with NaSCN, and adsorbed onto nitrocellulose or polystyrene supports. Antigens remain topographically separated from antibodies after removal of NaSCN and can be detected with radiolabeled antibodies. Genomes from viruses immobilized on nitrocellulose can be identified by nucleic acid hybridization. Nanogram quantities of sequestered hepatitis B surface and core antigens and picogram amounts of hepatitis B virus DNA were detected. Antibody-bound adenovirus, herpesvirus, and measles virus antigens were discerned by the procedure
Singh, Satwinder Kaur; Meyering, Maaike; Ramwadhdoebe, Tamara H; Stynenbosch, Linda F M; Redeker, Anke; Kuppen, Peter J K; Melief, Cornelis J M; Welters, Marij J P; van der Burg, Sjoerd H
2012-11-01
The ability to measure antigen-specific T cells at the single-cell level by intracellular cytokine staining (ICS) is a promising immunomonitoring tool and is extensively applied in the evaluation of immunotherapy of cancer. The protocols used to detect antigen-specific CD8+ T-cell responses generally work for the detection of antigen-specific T cells in samples that have undergone at least one round of in vitro pre-stimulation. Application of a common protocol but now using long peptides as antigens was not suitable to simultaneously detect antigen-specific CD8+ and CD4+ T cells directly ex vivo in cryopreserved samples. CD8 T-cell reactivity to monocytes pulsed with long peptides as antigens ranged between 5 and 25 % of that observed against monocytes pulsed with a direct HLA class I fitting minimal CTL peptide epitope. Therefore, we adapted our ICS protocol and show that the use of tenfold higher concentration of long peptides to load APC, the use of IFN-α and poly(I:C) to promote antigen processing and improve T-cell stimulation, does allow for the ex vivo detection of low-frequency antigen-specific CD8+ and CD4+ T cells in an HLA-independent setting. While most of the improvements were related to increasing the ability to measure CD8+ T-cell reactivity following stimulation with long peptides to at least 50 % of the response detected when using a minimal peptide epitope, the final analysis of blood samples from vaccinated patients successfully showed that the adapted ICS protocol also increases the ability to ex vivo detect low-frequency p53-specific CD4+ T-cell responses in cryopreserved PBMC samples.
Microradioimmunoassay for antibodies to tumor-associated antigens
International Nuclear Information System (INIS)
Huang, J.C.C.; Berczi, I.; Froese, G.; Tsay, H.M.; Sehon, A.H.
1975-01-01
A versatile microradioimmunoassay for the detection of antibodies to tumor-associated and other tissue antigens was described. The method involved: the preparation of solid-phase antigen with cultured (already adhered) or noncultured cells (sedimented by centrifugation) fixed to Micro-Test plates with neutral buffered formaldehyde or absolute methanol; the incubation of the antigen with test or control sera; and the incubation of the antigen with radioiodinated antiglobulin antibody. The nonspecific background of radioactivity was reduced to an acceptable level by the fixed cells being precoated in the wells with 0.5 percent bovine serum albumin in phosphate-buffered saline which was also used for the dilution of sera and labeled antiglobulin antibody. Tumor cells in primary cultures gave a high background, as compared to long-term cultures, which was due to the presence of immunoglobulins (most likely tumor-specific antibody). The specific antibody response to a syngeneic mouse tumor was demonstrated by this technique. (auth)
DEFF Research Database (Denmark)
Tian, Bo; Wetterskog, Erik; Qiu, Zhen
2017-01-01
anisotropy), and directly increasing the optomagnetic signal (via optical shape anisotropy). We achieve a limit of detection (LOD) of 5.5 pM (0.82 ng/mL) for the detection of a model multivalent molecule, biotinylated anti-streptavidin, in PBS. For the measurements of prostate-specific antigen (PSA) in 50...
Directory of Open Access Journals (Sweden)
Gema Álvarez García
2006-08-01
Full Text Available A Neospora caninum 17 kDa protein fraction (p17 has been described as an immunodominant antigen (IDA under reducing and non-reducing conditions. The aim of the present study was to investigate the diagnostic utility of p17 in cattle. In order to achieve this, p17 was purified by electroelution from whole N. caninum tachyzoite soluble extract and a p17-based Western blot (WB-p17 was developed. The p17 recognition was measured by densitometry and expressed as OD values to check the validity of the WB-p17. A total of 131 sera including sequential samples from naturally- and experimentally-infected calves and breeding cattle were analysed by WB-p17 and compared with IFAT using whole formalin-fixed tachyzoites as a reference test. The results obtained highlight the feasibility of using the N. caninum p17 in a diagnostic test in cattle. Firstly, the assay based on the p-17 antigen discriminated between known positive and negative sera from different cattle populations, breeding cattle and calves. Secondly, the p17 antigen detected fluctuations in the antibody levels and seroconversion in naturally- and experimentally-infected cattle. Significant differences in p-17 antigen recognition were observed between naturally infected aborting and non-aborting cattle, as well as significant antibody fluctuations over time in experimentally infected cattle, which varied between groups. Furthermore, the results obtained with WB-p17 are in accordance with the results obtained with the IFAT, as high agreement values were obtained when all bovine subpopulations were included (kappa = 0.86.
Crestani, Sandra; Leitolis, Amanda; Lima, Lucianna Freitas Oliveira; Krieger, Marco A; Foti, Leonardo
2016-08-01
Diverse techniques have been developed to analyze antibody-mediated responses to infections. However, the most common tests, i.e., enzyme-linked immunosorbent assays, require separate reactions for each antigen and consequently necessitate large sample volumes. Luminex technology allows the detection of multiple antibodies in a single experiment, but nonspecific binding can impair the results. Therefore, we examined the use of Escherichia coli lysates to reduce nonspecific binding and improve the results of liquid microarrays based on Luminex technology. Anti-bacteria antibodies were detected in human serum samples, as evidenced by high median fluorescence intensity (MFI) in assays performed with paramagnetic microspheres coupled with E. coli lysates. Moreover, the addition of an E. coli lysate as a blocker reduced the nonspecific binding of antigens produced by E. coli in a concentration-dependent manner. Tris-HCl reduced MFI values in negative samples, but did not affect MFI for positive samples. For microspheres coupled with different antigens, an E. coli lysate blocker significantly improved the fluorescence signals from positive samples. The addition of Tris-HCl and the E. coli lysate induced antigen-specific differences in MFI. This combination of the E. coli lysate blocker and Tris-HCl yielded a statistically significant improvement in MFI in the assays for Chagas disease and hepatitis C virus samples. However, for the Treponema pallidum p47 antigen improvement in MFI was only observed for the preparation with the E. coli blocker at a concentration of 3%. In conclusion, the addition of an E. coli lysate and Tris-HCl to the microarray assay reduced the nonspecific binding of human anti-bacteria antibodies and, therefore, increased the specific MFI. Copyright © 2016 Elsevier B.V. All rights reserved.
Binding of hydrophobic antigens to surfaces
DEFF Research Database (Denmark)
2017-01-01
A first aspect of the present invention is a method of detecting antibodies comprising the steps of: i) providing a first group of beads comprising a surface modified with C1-C10 alkyl groups comprising amine, ammonium, ether and/or hydroxyl groups, ii) contacting said first group of beads......-antigen-antibody conjugates, and v) detecting said bead-antigen-antibody conjugates. Further aspects include an antibody detection kit, a bead-antigen conjugate and a composition comprising at least two different groups of bead-antigen-conjugates....
Intra-uterine exposure of horses to Sarcocystis spp. antigens
Directory of Open Access Journals (Sweden)
A.M. Antonello
2016-04-01
Full Text Available The aim of this study was to examine the intra-uterine exposure to Sarcocystis spp. antigens, determining the number of foals with detectable concentrations of antibodies against these agents in the serum, before colostrum ingestion and collect data about exposure of horses to the parasite. Serum samples were collected from 195 thoroughbred mares and their newborns in two farms from southern Brazil. Parasite specific antibody responses to Sarcocystis antigens were detected using the indirect immunofluorescent antibody test (IFAT and immunoblot analysis. In 84.1% (159/189 of the pregnant mares and in 7.4% (14/189 of foals we detected antibodies anti-Sarcocystis spp. by IFAT. All samples seropositive from foals were also positive in their respective mares. Serum samples of seropositive foals by IFAT, showed no reactivity on the immunoblot, having as antigens S. neurona merozoites. In conclusion, the intra-uterine exposure to Sarcocystis spp. antigens in horses was demonstrated, with occurrence not only in mares, but also in their foals, before colostrum ingestion these occurrences were reduced.
Cornaglia, C; Robinet, J; Partouche, H
2009-06-01
The distribution of the Rapid Antigen Detection Test (RADT) and the National Health Insurance's information campaign should efficiently reduce the unjustified use antibiotic. However, a preliminary survey among GP trainers at the Paris Descartes University indicated that the RADT was seldom used. This study had for aim to describe the RADT use trend among trainers since 2005 and the main obstacles to its widespread use, and to assess the Mac Isaac score use and antibiotic prescriptions. Between February and May 2007, a survey was carried out among 66 GPs who were required to report their first ten patients over three years of age presenting with pharyngitis. RADT use and antibiotic prescriptions were compared with those of the 2005 survey. RADT use had decreased (52.5% [48.2-56.8] versus 57.5% [52.1-68.8], p<0.05). GPs did not use the RADT because they considered it "useless in decision making". Clinical findings were sufficient in most cases. The Mac Isaac score was not widely used by GPs (28.3%) and antibiotic prescription had increased except for macrolides which had decreased (10% vs 15%). Among patients with a negative RADT, 11.9% (vs 10.5% en 2005, p<0.001) were prescribed antibiotics. The RADT use decreased in two years among GP trainers. GPs still prescribe treatment according to clinical findings, most without using diagnostic tools.
International Nuclear Information System (INIS)
Lambden, P.R.; Watt, P.J.
1978-01-01
A solid phase radioimmunoassay (SPRIA) has been developed for detection of IgG antibodies to gonococcal outer membrane components. Gonococcal antigens was immobilised on a solid support by covalent coupling to CNBr-activated Sepharose in the presence of the detergent Triton X-100. Binding of specific antibody to the Sepharose-antigen complex was detected using radiolabelled Protein A as the antiglobulin. Protein A was labelled by radioacetylation with tritiated acetic anhydride, yielding a product of high specific activity and high stability. No detectable loss of activity was observed over a ten month period. The entire assay was performed on Mitex teflon hydrophobic membrane filters which held the Sepharose beads and aqueous supernatant as a discrete drop of liquid. The supernatants and incubation were easily and rapidly removed from the beads by suction on a specially-designed manifold system. This procedure removed the need for repeated and time-consuming centrifugations. Titres were obtained graphically from double log plots of cpm bound versus antiserum dilution by extrapolation of the straight line to a point corresponding to twice the control level of radioactivity binding. The assay proved to be a very reliable and simple procedure for the detection of IgG antibodies to gonococcal surface antigens. (Auth.)
DEFF Research Database (Denmark)
Arnot, David E; Cavanagh, David R; Remarque, Edmond J
2008-01-01
Immunogenicity testing of Plasmodium falciparum antigens being considered as malaria vaccine candidates was undertaken in rabbits. The antigens compared were recombinant baculovirus MSP-1(19) and five Pichia pastoris candidates, including two versions of MSP-1(19), AMA-1 (domains I and II), AMA-1......G concentrations. The two P. pastoris-produced MSP-1(19)-induced IgGs conferred the lowest growth inhibition. Comparative analysis of immunogenicity of vaccine antigens can be used to prioritize candidates before moving to expensive GMP production and clinical testing. The assays used have given discriminating...
Krivitsky, Vadim; Zverzhinetsky, Marina; Patolsky, Fernando
2016-10-12
The detection of biomolecules is critical for a wide spectrum of applications in life sciences and medical diagnosis. Nonetheless, biosamples are highly complex solutions, which contain an enormous variety of biomolecules, cells, and chemical species. Consequently, the intrinsic chemical complexity of biosamples results in a significant analytical background noise and poses an immense challenge to any analytical measurement, especially when applied without prior efficient separation and purification steps. Here, we demonstrate the application of antigen-dissociation regime, from antibody-modified Si-nanowire sensors, as a simple and effective direct sensing mechanism of biomarkers of interest in complex biosamples, such as serum and untreated blood, which does not require ex situ time-consuming biosample manipulation steps, such as centrifugation, filtering, preconcentration, and desalting, thus overcoming the detrimental Debye screening limitation of nanowire-based biosensors. We found that two key parameters control the capability to perform quantitative biomarkers analysis in biosamples: (i) the affinity strength (k off rate) of the antibody-antigen recognition pair, which dictates the time length of the high-affinity slow dissociation subregime, and (ii) the "flow rate" applied during the solution exchange dissociation step, which controls the time width of the low-affinity fast-dissociation subregime. Undoubtedly, this is the simplest and most convenient approach for the SiNW FET-based detection of antigens in complex untreated biosamples. The lack of ex situ biosample manipulation time-consuming processes enhances the portability of the sensing platform and reduces to minimum the required volume of tested sample, as it allows the direct detection of untreated biosamples (5-10 μL blood or serum), while readily reducing the detection cycle duration to less than 5 min, factors of great importance in near-future point-of-care medical applications. We believe
Directory of Open Access Journals (Sweden)
Lynette Beattie
2010-03-01
Full Text Available Kupffer cells (KCs represent the major phagocytic population within the liver and provide an intracellular niche for the survival of a number of important human pathogens. Although KCs have been extensively studied in vitro, little is known of their in vivo response to infection and their capacity to directly interact with antigen-specific CD8(+ T cells. Here, using a combination of approaches including whole mount and thin section confocal microscopy, adoptive cell transfer and intra-vital 2-photon microscopy, we demonstrate that KCs represent the only detectable population of mononuclear phagocytes within granulomas induced by Leishmania donovani infection that are capable of presenting parasite-derived peptide to effector CD8(+ T cells. This restriction of antigen presentation to KCs within the Leishmania granuloma has important implications for the identification of new candidate vaccine antigens and for the design of novel immuno-therapeutic interventions.
DEFF Research Database (Denmark)
Bentzen, Amalie Kai; Marquard, Andrea Marion; Lyngaa, Rikke Birgitte
2016-01-01
-major histocompatibility complex (MHC) multimers labeled with individual DNA barcodes to screen >1,000 peptide specificities in a single sample, and detect low-frequency CD8 T cells specific for virus- or cancer-restricted antigens. When analyzing T-cell recognition of shared melanoma antigens before and after adoptive...... cell therapy in melanoma patients, we observe a greater number of melanoma-specific T-cell populations compared with cytometry-based approaches. Furthermore, we detect neoepitope-specific T cells in tumor-infiltrating lymphocytes and peripheral blood from patients with non-small cell lung cancer...
I-125 input into antibodies molecules specific to australian antigen
International Nuclear Information System (INIS)
Abdukayumov, A. M.; Chistyakov, P.G.; Garajshina, G. R.
1999-01-01
There are experimental data on I-125 input into antibodies molecules specific to superficial antigen of hepatitis B virus (australian antigen). Three ways of input are submitted: with the help of T chloramine usage, Bolton-Hunter Reagent and with the help of iodogen. There are also comparative characteristics of iodized products obtained: molar radioactivity, radiochemical frequency, immuno - reactivity. The report also discusses advantages and disadvantages of the used methods for inputting I-125 into antibodies to australian antigen in order to study the possibility of creating radio immunological test system for detecting superficial antigen of B hepatitis
Weiner, Zachary P.; Crew, Rebecca M.; Brandt, Kevin S.; Ullmann, Amy J.; Schriefer, Martin E.; Molins, Claudia R.
2015-01-01
Laboratory testing for the diagnosis of Lyme disease is performed primarily by serologic assays and is accurate for detection beyond the acute stage of the infection. Serodiagnostic assays to detect the early stages of infection, however, are limited in their sensitivity, and improvement is warranted. We analyzed a series of Borrelia burgdorferi proteins known to be induced within feeding ticks and/or during mammalian infection for their utility as serodiagnostic markers against a comprehensive panel of Lyme disease patient serum samples. The antigens were assayed for IgM and IgG reactivity in line immunoblots and separately by enzyme-linked immunosorbent assay (ELISA), with a focus on reactivity against early Lyme disease with erythema migrans (EM), early disseminated Lyme neuroborreliosis, and early Lyme carditis patient serum samples. By IgM immunoblotting, we found that recombinant proteins BBA65, BBA70, and BBA73 reacted with early Lyme EM samples at levels comparable to those of the OspC antigen used in the current IgM blotting criteria. Additionally, these proteins reacted with serum samples from patients with early neuroborreliosis and early carditis, suggesting value in detecting early stages of this disease progression. We also found serological reactivity against recombinant proteins BBA69 and BBA73 with early-Lyme-disease samples using IgG immunoblotting and ELISA. Significantly, some samples that had been scored negative by the Centers for Disease Control and Prevention-recommended 2-tiered testing algorithm demonstrated positive reactivity to one or more of the antigens by IgM/IgG immunoblot and ELISA. These results suggest that incorporating additional in vivo-expressed antigens into the current IgM/IgG immunoblotting tier in a recombinant protein platform assay may improve the performance of early-Lyme-disease serologic testing. PMID:26376927
Weiner, Zachary P; Crew, Rebecca M; Brandt, Kevin S; Ullmann, Amy J; Schriefer, Martin E; Molins, Claudia R; Gilmore, Robert D
2015-11-01
Laboratory testing for the diagnosis of Lyme disease is performed primarily by serologic assays and is accurate for detection beyond the acute stage of the infection. Serodiagnostic assays to detect the early stages of infection, however, are limited in their sensitivity, and improvement is warranted. We analyzed a series of Borrelia burgdorferi proteins known to be induced within feeding ticks and/or during mammalian infection for their utility as serodiagnostic markers against a comprehensive panel of Lyme disease patient serum samples. The antigens were assayed for IgM and IgG reactivity in line immunoblots and separately by enzyme-linked immunosorbent assay (ELISA), with a focus on reactivity against early Lyme disease with erythema migrans (EM), early disseminated Lyme neuroborreliosis, and early Lyme carditis patient serum samples. By IgM immunoblotting, we found that recombinant proteins BBA65, BBA70, and BBA73 reacted with early Lyme EM samples at levels comparable to those of the OspC antigen used in the current IgM blotting criteria. Additionally, these proteins reacted with serum samples from patients with early neuroborreliosis and early carditis, suggesting value in detecting early stages of this disease progression. We also found serological reactivity against recombinant proteins BBA69 and BBA73 with early-Lyme-disease samples using IgG immunoblotting and ELISA. Significantly, some samples that had been scored negative by the Centers for Disease Control and Prevention-recommended 2-tiered testing algorithm demonstrated positive reactivity to one or more of the antigens by IgM/IgG immunoblot and ELISA. These results suggest that incorporating additional in vivo-expressed antigens into the current IgM/IgG immunoblotting tier in a recombinant protein platform assay may improve the performance of early-Lyme-disease serologic testing. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Lee, I.-K.; Jeun, M.; Jang, H.-J.; Cho, W.-J.; Lee, K. H.
2015-10-01
Ion-sensitive field-effect transistors (ISFETs), although they have attracted considerable attention as effective immunosensors, have still not been adopted for practical applications owing to several problems: (1) the poor sensitivity caused by the short Debye screening length in media with high ion concentration, (2) time-consuming preconditioning processes for achieving the highly-diluted media, and (3) the low durability caused by undesirable ions such as sodium chloride in the media. Here, we propose a highly sensitive immunosensor based on a self-amplified transistor under dual gate operation (immuno-DG ISFET) for the detection of hepatitis B surface antigen. To address the challenges in current ISFET-based immunosensors, we have enhanced the sensitivity of an immunosensor by precisely tailoring the nanostructure of the transistor. In the pH sensing test, the immuno-DG ISFET showed superior sensitivity (2085.53 mV per pH) to both standard ISFET under single gate operation (58.88 mV per pH) and DG ISFET with a non-tailored transistor (381.14 mV per pH). Moreover, concerning the detection of hepatitis B surface antigens (HBsAg) using the immuno-DG ISFET, we have successfully detected trace amounts of HBsAg (22.5 fg mL-1) in a non-diluted 1× PBS medium with a high sensitivity of 690 mV. Our results demonstrate that the proposed immuno-DG ISFET can be a biosensor platform for practical use in the diagnosis of various diseases.Ion-sensitive field-effect transistors (ISFETs), although they have attracted considerable attention as effective immunosensors, have still not been adopted for practical applications owing to several problems: (1) the poor sensitivity caused by the short Debye screening length in media with high ion concentration, (2) time-consuming preconditioning processes for achieving the highly-diluted media, and (3) the low durability caused by undesirable ions such as sodium chloride in the media. Here, we propose a highly sensitive immunosensor
Wang, Yixin; Chen, Hao; Zhao, Peng; Li, Jianliang; Cui, Zhizhong
2013-03-04
To prepare anti-fps mono-specific serum, and detect the fps antigen in tumors induced by acute transforming avian leukosis/sarcoma virus containing v-fps oncogene. Two part of v-fps gene was amplified by RT-PCR using the Fu-J viral RNA as the template. Mono-specific serum was prepared by immuning Kunming white mouse with both two recombinant infusion proteins expressed by the prokaryotic expression system. Indirect immunofluorescent assay was used to detect fps antigen in tumor tissue suspension cells and CEF infected by sarcoma supernatant. Immunohistochemical method was used to detect fps antigen in tumor tissue. The mouse mono-specific serum was specific as it had no cross reaction with classical ALV-J strains. The result reveals that the tumor tissue suspension cells, the CEF infected by sarcoma supernatant, and the slice immunohistochemistry of the sarcoma showed positive results. The anti-fps mono-specific serum was prepared, and the detection method was established, which laid the foundation for the study of viral biological characteristics and mechanism of tumourgenesis of acute transforming avian leukosis/sarcoma virus containing v-fps oncogene.
Directory of Open Access Journals (Sweden)
Raymundo Rizaldo Pinheiro
2005-12-01
Full Text Available The Caprine Arthritis Encephalitis (CAE is a disease who cause considerable economic losses, including loss in the milk production and reduction of the useful life of the animal. In the diagnosis of this disease the agar gel immunodifusion test (AGID is used worldwide as the selection test. The objective of thid work was to test three different concentrations of bovine fetal serum (BFS in the production of the antigen (Ag for the diagnosis of the CAE virus (CAEV, to verify amongst the three methods the most efficient concentration and which the antigen concentration of the antigen produced is appropriate for the test. The method of the AMICON and the concentration of the Ag for dialysis was indicated, however the system AMICON, despite the implantation costs, promoted minor loss of antigen, little time expense in the processing and greater simplicity. With relation to the amount of BFS placed after the viral inoculation it was verified that 5% of BFS the amount that presented better resulted. The antigen concentration 100 times was more indicated, therefore it allowed the diagnosis of the CAEV for two proteins (gp 135 and p28. The concentration of the Ag for precipitation/ultracentrifugation, used for imunoenzimatic tests, did not present resulted satisfactory used in the AGID.
COLONOSCOPY AND CARCINOEMBRYONIC ANTIGEN VARIATIONS
Directory of Open Access Journals (Sweden)
Rita G SOUSA
2014-03-01
Full Text Available Context Colonoscopy is essential for synchronous and metachronous cancer detection. Carcinoembryonic antigen is a colorectal cancer tumor marker, important as a follow-up tool in patients with previous colorectal cancer. False-positive carcinoembryonic antigen elevation results in multiples exams and in patient anxiety. In literature, there is reference to transient carcinoembryonic antigen increase with colonoscopy. Objective To evaluate the influence of bowel preparation and colonoscopy in carcinoembryonic antigen blood levels. Methods We prospectively studied subjects that underwent routine colonoscopy in our institution. Blood samples were collected (1 before bowel cleaning, (2 before colonoscopy and (3 immediately after colonoscopy. Blood carcinoembryonic antigen levels were determined by “Sandwich” immunoassay. The statistical methods used were the paired t-test and ANOVA. Results Thirty-seven patients (22M/15F were included; age range 28-84 (mean 56 years. Mean carcinoembryonic antigen values were 1.9, 2 and 1.8 for (1, (2 and (3, respectively. An increase in value (2 compared with (1 was observed in 20/37 patients (P = 0.018, mainly in younger patients and in patients requiring more endoluminal interventions. In 29/37 patients, the CEA value decreased from (2 to (3 (P = 1.3x10-7. Conclusions A trend for carcinoembryonic antigen increase after bowel cleaning was observed, especially in younger patients and in patients with more endoluminal interventions, but without clinical meaning.
Barfield, C. A.; Barney, R. S.; Crudder, C. H.; Wilmoth, J. L.; Stevens, D. S.; Mora-Garcia, S.; Yanovsky, M. J.; Weigl, B. H.; Yanovsky, J.
2011-01-01
Improved diagnostic tests for Chagas disease are urgently needed. A new lateral flow rapid test for Chagas disease is under development at PATH, in collaboration with Laboratorio Lemos of Argentina, which utilizes a recombinant antigen for detection of antibodies to Trypanosoma cruzi. To evaluate the performance of this test, 375 earlier characterized serum specimens from a region where Chagas is endemic were tested using a reference test (the Ortho T. cruzi ELISA, Johnson & Johnson), a commercially available rapid test (Chagas STAT-PAK, Chembio), and the PATH–Lemos rapid test. Compared to the composite reference tests, the PATH–Lemos rapid test demonstrated an optimal sensitivity of 99.5% and specificity of 96.8%, while the Chagas STAT-PAK demonstrated a sensitivity of 95.3% and specificity of 99.5%. These results indicate that the PATH–Lemos rapid test shows promise as an improved and reliable tool for screening and diagnosis of Chagas disease. PMID:21342808
Antigenic evaluation of a recombinant baculovirus-expressed Sarcocystis neurona SAG1 antigen.
Gupta, G D; Lakritz, J; Saville, W J; Livingston, R S; Dubey, J P; Middleton, J R; Marsh, A E
2004-10-01
Sarcocystis neurona is the primary parasite associated with equine protozoal myeloencephalitis (EPM). This is a commonly diagnosed neurological disorder in the Americas that infects the central nervous system of horses. Current serologic assays utilize culture-derived parasites as antigen. This method requires large numbers of parasites to be grown in culture, which is labor intensive and time consuming. Also, a culture-derived whole-parasite preparation contains conserved antigens that could cross-react with antibodies against other Sarcocystis species and members of Sarcocystidae such as Neospora spp., Hammondia spp., and Toxoplasma gondii. Therefore, there is a need to develop an improved method for the detection of S. neurona-specific antibodies. The sera of infected horses react strongly to surface antigen 1 (SnSAG1), an approximately 29-kDa protein, in immunoblot analysis, suggesting that it is an immunodominant antigen. The SnSAG1 gene of S. neurona was cloned, and recombinant S. neurona SAG1 protein (rSnSAG1-Bac) was expressed with the use of a baculovirus system. By immunoblot analysis, the rSnSAG1-Bac antigen detected antibodies to S. neurona from naturally infected and experimentally inoculated equids, cats, rabbit, mice, and skunk. This is the first report of a baculovirus-expressed recombinant S. neurona antigen being used to detect anti-S. neurona antibodies in a variety of host species.
Directory of Open Access Journals (Sweden)
Ganna Chornokur
2011-01-01
Full Text Available This paper reports the successful fabrication of an impedance-based miniaturized biosensor and its application for ultrasensitive Prostate-Specific Antigen (PSA detection in standard and real human plasma solution, spiked with different PSA concentrations. The sensor was fabricated using photolithographic techniques, while monoclonal antibodies specific to human PSA were used as primary capture antibodies. Electrochemical impedance spectroscopy (EIS was employed as a detection technique. The sensor exhibited a detection limit of 1 pg/ml for PSA with minimal nonspecific binding (NSB. This detection limit is an order of magnitude lower than commercial PSA ELISA assays available on the market. The sensor can be easily modified into an array for the detection of other biomolecules of interest, enabling accurate, ultrasensitive, and inexpensive point-of-care sensing technologies.
Directory of Open Access Journals (Sweden)
Wang S
2016-01-01
Full Text Available Shuo Wang, Wanming Li, Dezheng Yuan, Jindan Song, Jin Fang Department of Cell Biology, Key Laboratory of Cell Biology, Ministry of Public Health, and Key Laboratory of Medical Cell Biology, Ministry of Education, China Medical University, Shenyang, People’s Republic of China Abstract: The large external antigen (LEA is a cell surface glycoprotein that has been proven to be highly expressed in colorectal cancer (CRC as a tumor-associated antigen. To evaluate and validate the relationship between LEA expression and clinical characteristics of CRC with high efficiency, LEA expression levels were detected in 85 tissue blocks from CRC patients by quantum dot-based immunohistochemistry (QD-IHC combined with imaging quantitative analysis using quantum dots with a 605 nm emission wavelength (QD605 conjugated to an ND-1 monoclonal antibody against LEA as a probe. Conventional IHC was performed in parallel for comparison. Both QD-IHC and conventional IHC showed that LEA was specifically expressed in CRC, but not in non-CRC tissues, and high LEA expression was significantly associated with a more advanced T-stage (P<0.05, indicating that LEA is likely to serve as a CRC prognostic marker. Compared with conventional IHC, receiver operating characteristic analysis revealed that QD-IHC possessed higher sensitivity, resulting in an increased positive detection rate of CRC, from 70.1% to 89.6%. In addition, a simpler operation, objective analysis of results, and excellent repeatability make QD-IHC an attractive alternative to conventional IHC in clinical practice. Furthermore, to explore whether the QD probes can be utilized to quantitatively detect living cells or single cells, quantum dot-based immunocytochemistry (QD-ICC combined with imaging quantitative analysis was developed to evaluate LEA expression in several CRC cell lines. It was demonstrated that QD-ICC could also predict the correlation between LEA expression and the T-stage characteristics of
Morioka, Kazuki; Fukai, Katsuhiko; Sakamoto, Kenichi; Yoshida, Kazuo; Kanno, Toru
2014-01-01
A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) method was previously developed for foot-and-mouth disease (FMD) viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS)-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01). In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01). Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.
Millman, I; Glass, R G
1988-05-01
'Ausria II' polystyrene beads (Abbott Labs, N. Chicago) are reacted with woodchuck serum positive for WHsAg in a dilution predetermined by titration. This modified bead is used in a blocking assay to detect the presence of antibody to the surface antigen of woodchuck hepatitis virus (anti-WHs). Serum containing woodchuck anti-WHs and commercial horseradish peroxidase (HRP) labeled anti-HBs are sequentially added. A drop in optical density at 492 nm of 50% or more due to the blocking of HRP conjugated anti-HBs by anti-WHs compared with a control (negative woodchuck serum) is a measure of anti-WHs. The ease and simplicity of converting readily available 'Ausria II' beads to specific reagents for detecting anti-WHs should be welcomed by investigators studying WHV. The method described is both sensitive and reproducible.
Chen, Ming; Zhou, Ming; Xiao, Wei; Ai, Biao; Liu, Xuezheng; Li, Yan
2014-11-01
Antibiotic treatment before microbiological test significant reduces the positive rate of culture methods of Streptococcus pneumoniae. The Binax NOW S. pneumoniae immunochromatographic test (ICT) has become a more commonly used procedure to diagnose S. pneumoniae from community-acquired pneumonia in adults. However, performance of this test after empirical antimicrobial therapy is uncertain. Therefore, in this prospective study, we evaluate the impact of antimicrobial therapy on sensitivity of ICT test in 487 hospitalized adult patients. The results showed that 192 (39.4 %) and 295 (60.6 %) specimens were collected before (Group 1) or after antibiotic treatment (Group 2), respectively. S. pneumoniae was detected by ICT in 21 (10.9 %) patients in the Group 1 and 39 (13.2 %) in the Group 2 and their positive rates were not different (P > 0.05). However, The positive rate of blood and pleural fluid was declined from 5.7 to 2.7 % and sputum, from 9.9 to 4.7 % after the antibiotic treatment, respectively. This study confirmed that the ICT urinary antigen test remained to have a high sensitivity for diagnosis of pneumococcal infection after empiric antibiotic treatment was started. The ICT urinary antigen test would have a potential to guide the right choice of therapy for pneumonia in adults earlier.
DEFF Research Database (Denmark)
Bentzen, Amalie Kai; Marquard, Andrea Marion; Lyngaa, Rikke Birgitte
2016-01-01
diversity of T cell recognition in humans. Consequently it has been impossible to comprehensively analyze T cell responsiveness in cancer, infectious and autoimmune diseases. We present and validate a novel technology that enables parallel detection of numerous different peptide-MHC responsive T cells...... with combinatorial encoding of fluorescent-labeled MHC multimers. Finally, we have demonstrated that this technology can be applied for multiplex T cell detection both in limited biological samples, such as uncultured tumor material, and for simultaneous assessment of target recognition and functional capability...... of T cells. This technology enables true high-throughput detection of antigen-responsive T cells and will advance our understanding of immune recognition from model antigens to genomewide immune assessments on a personalized basis....
Vickers, Andrew J; Wolters, Tineke; Savage, Caroline J; Cronin, Angel M; O'Brien, M Frank; Roobol, Monique J; Aus, Gunnar; Scardino, Peter T; Hugosson, Jonas; Schröder, Fritz H; Lilja, Hans
2010-09-01
Prostate specific antigen velocity has been proposed as a marker to aid in prostate cancer detection. We determined whether prostate specific antigen velocity could predict repeat biopsy results in men with persistently increased prostate specific antigen after initial negative biopsy. We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer and who underwent 1 or more subsequent prostate biopsies after an initial negative finding. We evaluated whether prostate specific antigen velocity improved predictive accuracy beyond that of prostate specific antigen alone. Of the 2,579 repeat biopsies 363 (14%) were positive for prostate cancer, of which 44 (1.7%) were high grade (Gleason score 7 or greater). Prostate specific antigen velocity was statistically associated with cancer risk but had low predictive accuracy (AUC 0.55, p <0.001). There was some evidence that prostate specific antigen velocity improved AUC compared to prostate specific antigen for high grade cancer. However, the small increase in risk associated with high prostate specific antigen velocity (from 1.7% to 2.8% as velocity increased from 0 to 1 ng/ml per year) had questionable clinical relevance. Men with prior negative biopsy are at lower risk for prostate cancer at subsequent biopsies with high grade disease particularly rare. We found little evidence to support prostate specific antigen velocity to aid in decisions about repeat biopsy for prostate cancer. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Development of a PMMA Electrochemical Microfluidic Device for Carcinoembryonic Antigen Detection
Van Anh, Nguyen; Van Trung, Hoang; Tien, Bui Quang; Binh, Nguyen Hai; Ha, Cao Hong; Le Huy, Nguyen; Loc, Nguyen Thai; Thu, Vu Thi; Lam, Tran Dai
2016-05-01
In this study, a poly(methyl methacrylate) (PMMA) microfluidic device fabricated by an inexpensive CO2 laser etching system was developed for detection of carcino-embryonic antigens (CEA). The device was capable of working in continuous mode and was designed with the aid of numerical simulation. The detection of target CEA was based on immuno-assay via magnetic particles and electrochemical sensing. The as-prepared microfluidic can be used to detect CEA at the relatively low concentration of 150 pg mL-1. The device could be reused many times, since the capture and removal of magnetic particles in the assay could be manipulated by an external magnetic field. The proposed approach appears to be suitable for high-throughput and automated analysis of large biomolecules such as tumor markers and pathogens.
The use of the antigen ELISA for monitoring tsetse and trypanosomosis control programmes in Zimbabwe
Energy Technology Data Exchange (ETDEWEB)
Ries, R; Nqindi, J [Central Veterinary Lab., Causeway, Harare (Zimbabwe)
1997-02-01
Blood and serum samples from cattle originating from tsetse free and tsetse infested areas were analyzed using the Buffy Coat technique and an ELISA to detect trypanosomes and trypanosomal antigens, respectively. The results of the two tests were compared and apparent sensitivity and trypanosomal prevalence were calculated. The BCT seemed to be the most suitable test to detect acute infections, while the antigen capture ELISA (Ag-ELISA) was able to detect more chronic infections. The specificity of the Ag-ELISA was found to be very good, but the sensitivity of the test should be improved. One way to detect more T. congolense and T. vivax infections was to lower the cut-off point of percent positivity from 10 to 5%. (author). 1 ref., 1 fig., 7 tabs.
The use of the antigen ELISA for monitoring tsetse and trypanosomosis control programmes in Zimbabwe
International Nuclear Information System (INIS)
Ries, R.; Nqindi, J.
1997-01-01
Blood and serum samples from cattle originating from tsetse free and tsetse infested areas were analyzed using the Buffy Coat technique and an ELISA to detect trypanosomes and trypanosomal antigens, respectively. The results of the two tests were compared and apparent sensitivity and trypanosomal prevalence were calculated. The BCT seemed to be the most suitable test to detect acute infections, while the antigen capture ELISA (Ag-ELISA) was able to detect more chronic infections. The specificity of the Ag-ELISA was found to be very good, but the sensitivity of the test should be improved. One way to detect more T. congolense and T. vivax infections was to lower the cut-off point of percent positivity from 10 to 5%. (author). 1 ref., 1 fig., 7 tabs
9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3
2010-01-01
...-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure described is a modification of the method reported by Schaffer, MacDonald, Hall, and Bunyea, Jour. Amer. Vet...
Directory of Open Access Journals (Sweden)
Marjorie S Morgan
2017-06-01
Full Text Available Scabies, caused by the mite, Sarcoptes scabiei, infects millions of humans, and many wild and domestic mammals. Scabies mites burrow in the lower stratum corneum of the epidermis of the skin and are the source of substances that are antigenic or modulate aspects of the protective response of the host. Ordinary scabies is a difficult disease to diagnose.The goal of this project was to identify S. scabiei proteins that may be candidate antigens for use in a diagnostic test or may be used by the mite to modulate the host's protective response.An aqueous extract of S. scabiei was separated by 2-dimensional electrophoresis and proteins were identified by mass spectrometry. A parallel immunoblot was probed with serum from patients with ordinary scabies to identify IgM and/or IgG-binding antigens. The genes coding for 23 selected proteins were cloned into E. coli and the expressed recombinant proteins were screened with serum from patients with confirmed ordinary scabies.We identified 50 different proteins produced by S. scabiei, 34 of which were not previously identified, and determined that 66% were recognized by patient IgM and/or IgG. Fourteen proteins were screened for use in a diagnostic test but none possessed enough sensitivity and specificity to be useful. Six of the 9 proteins selected for the possibility that they may be immunomodulatory were not recognized by antibodies in patient serum.Thirty-three proteins that bound IgM and/or IgG from the serum of patients with ordinary scabies were identified. None of the 14 tested were useful for inclusion in a diagnostic test. The identities of 16 proteins that are not recognized as antigens by infected patients were also determined. These could be among the molecules that are responsible for this mite's ability to modulate its host's innate and adaptive immune responses.
Alter, H J; Epstein, J S; Swenson, S G; VanRaden, M J; Ward, J W; Kaslow, R A; Menitove, J E; Klein, H G; Sandler, S G; Sayers, M H
1990-11-08
We performed a multicenter study in 1989 to determine whether screening whole-blood donors for human immunodeficiency virus type 1 (HIV-1) p24 antigen would improve transfusion safety by identifying carriers of the virus who are seronegative for HIV-1 antibody. More than 500,000 donations were tested at 13 U.S. blood centers with test kits from two manufacturers. Units found repeatedly reactive were retested in a central laboratory; if the results were positive, they were confirmed by a neutralization assay. A subgroup of units was also tested for HIV-1 by the polymerase chain reaction. Selected donors confirmed or not confirmed as having p24 antigen were contacted for follow-up interviews to identify risk factors and undergo retesting for HIV-1 markers. Positive tests for p24 antigen were confirmed by neutralization in five donors (0.001 percent of all donations tested), all of whom were also positive for HIV-1 antibody and HIV-1 by polymerase chain reaction. Three of the antigen-positive donors had other markers of infectious disease that would have resulted in the exclusion of their blood; two had risk factors for HIV-1 that should have led to self-exclusion. Of 220 blood units with repeatedly reactive p24 antigen whose presence could not be confirmed by neutralization (0.04 percent of the donations studied), none were positive for HIV-1 antibody, HIV-1 by polymerase chain reaction (120 units tested), or virus culture (76 units tested)--attesting to the specificity of confirmatory neutralization. The finding that no donation studied was positive for p24 antigen and negative for HIV-1 antibody suggests that screening donors for p24 antigen with tests of the current level of sensitivity would not add substantially to the safety of the U.S. blood supply.
International Nuclear Information System (INIS)
Schild, G.C.; Wood, J.M.; Minor, P.D.; Dandawate, C.N.; Magrath, D.I.
1980-01-01
The reactions of polioviruses in single-radial-immunodiffusion (SRD) tests were investigated with a view to developing accurate and sensitive antigen assay systems. In direct SRD tests, the reactions were type-specific for polioviruses of types 1, 2 and 3 but the tests were of low sensitivity, being applicable only to the assay of virus concentrates. A novel autoradiographic zone size enhancement (ZE) test was developed which increased the sensitivity of the SRD assay 40-to 100-fold. The ZE test was dependent upon the ability of unlabelled poliovirus to co-migrate with the radioactive marker virus and so enhance the zone size detected autoradiographically. The areas of the autoradiographic zones were directly proportional to the concentration of unlabelled antigen. The ZE test was capable of detecting poliovirus D antigens in amounts corresponding to 10sup(3.3) to 10sup(4.3) TCID 50 of infectious virus. Studies with poliovirus type 3 strains indicated that the ZE test was narrowly strain-specific for the D-antigen of poliovirus type 3 strains when homologous type 3 D-antigen was used as radioactive marker, but broadly cross-reactive for the D-antigen of type 3 viruses when heterologous poliovirus type 3 D-antigen was used as marker. (author)
El Harith, A.; Chowdhury, S.; Al-Masum, A.; Semião-Santos, S.; Das, P. K.; Akhter, S.; Vetter, J. C.; Haq, I.
1996-01-01
A direct agglutination test (DAT) for the detection of post-kala azar dermal leishmaniasis (PKDL) was evaluated in conditions that simulate the disease clinically or immunologically. A reference strain of Leishmania donovani (LEM 1399), and antigen preparations from Leishmania isolates from
Directory of Open Access Journals (Sweden)
Antonios Perdikaris
2009-03-01
Full Text Available A novel miniature cell biosensor detection system for the detection of Hepatis B virus (HBV-associated antigens and anti-HBV is described. The biosensor is based on “membrane-engineered” Vero fibroblast cells immobilized in an alginate matrix. The membrane-engineering process involved the electroinsertion of anti-HBV specific antibodies (anti-HBs, anti-HBe or antigens (HBsAg in the membranes of the Vero cells. The attachment of a homologous antigen to the electroinserted antibody (or, respectively, of the antibody to the electroinserted antigen triggered specific changes to the cell membrane potential that were measured by appropriate microelectrodes, according to the principle of the Bioelectric Recognition Assay (BERA. The sensor was used for screening 133 clinical blood serum samples according to a double-blind protocol. Considerably higher sensor responses were observed against HBV-positive samples, compared with responses against negative samples or samples positive for heterologous hepatitis viruses such as Hepatitis C (HCV virus. Detection of anti-HBs antibodies was made possible by using a biosensor based on immobilized Vero cells bearing the respective antigen (HBsAg. The observed response was rapid (45 sec and quite reproducible. Fluorescence microscopy observations showed that attachment of HBV particles to cells membrane-engineered with anti-HBs was associated with a decrease of [Ca2+]cyt. The perspectives for using the novel biosensor as a qualitative, rapid screening, high throughput assay for HBV antigens and anti-HBs in clinical samples is discussed.
Directory of Open Access Journals (Sweden)
T. Sabbi
2012-04-01
Full Text Available Background: helicobacter pylori (hp infection is mainly acquired during childhood; it is recognised as a cause of gastritis and peptic ulcer and it has been classified as a group A carcinogen by World health organization. the exact mode of transmission is as yet, not known. Aim of our study has been to identify risk factors associated with helicobacter pylori infection in a preschool and school population and to confirm if hp antigen in faeces is useful as screening in epidemiological studies. Methods: We interviewed, with questionnaire, 400 children (203 male; age range 3-10 years; mean age 6 years of 3 different schools and stool samples were collected of all children too. 35 of 400 (8% children underwent to upper gastrointestinal endoscopy because of a suspect of upper gastrointestinal disease. Results: stool were collected from 400 school children and 35 of them shown positivity of hp antigen test. A questionnaire about presence of nausea, vomit, recurrent abdominal pain, family size, parent’s occupations and education, use of antibiotics, country of birth of child and parents, personal hygiene, breast feeding, presence of the animals was completed. 35 children with positive hp stool antigen test and a suspicious of upper gastrointestinal disease (recurrent abdominal pain, diurnal or nocturnal abdominal pain, nausea, vomiting, iron deficiency underwent to esophagogastroduodenoscopy (egdS that demonstrated antral gastritis and positive histology and urease rapid test. Conclusions: the results of this study suggest that risk factors for hp infection are low socioeconomics factors, hygiene and living conditions and that hp antigen in faeces is useful as screening test.
Sabbi, T; Dall'Oglio, L; De Angelis, P; Torroni, E; Colistro, F; Azzolina, M; Santoni, A; Di Ciommo, V; Benedetto, M
2012-01-01
Helicobacter pylori (Hp) infection is mainly acquired during childhood; it is recognised as a cause of gastritis and peptic ulcer and it has been classified as a group A carcinogen by World Health Organization. The exact mode of transmission is as yet, not known. Aim of our study has been to identify risk factors associated with Helicobacter pylori infection in a preschool and school population and to confirm if Hp antigen in faeces is useful as screening in epidemiological studies. We interviewed, with questionnaire, 400 children (203 male; age range 3-10 years; mean age 6 years) of 3 different schools and stool samples were collected of all children too. 35 of 400 (8%) children underwent to upper gastrointestinal endoscopy because of a suspect of upper gastrointestinal disease. stool were collected from 400 school children and 35 of them shown positivity of Hp antigen test. A questionnaire about presence of nausea, vomit, recurrent abdominal pain, family size, parent's occupations and education, use of antibiotics, country of birth of child and parents, personal hygiene, breast feeding, presence of the animals was completed. 35 children with positive Hp stool antigen test and a suspicious of upper gastrointestinal disease (recurrent abdominal pain, diurnal or nocturnal abdominal pain, nausea, vomiting, iron deficiency) underwent to esophagogastroduodenoscopy (EGDS) that demonstrated antral gastritis and positive histology and urease rapid test. the results of this study suggest that risk factors for Hp infection are low socioeconomics factors, hygiene and living conditions and that Hp antigen in faeces is useful as screening test.
Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.
Directory of Open Access Journals (Sweden)
Subhamoy Pal
Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.
International Nuclear Information System (INIS)
Kato, Seiichi; Minoura, Takanori; Iinuma, Kazuie; Konno, Mutsuko; Tajiri, Hitoshi; Matsuhisa, Takeshi
2004-01-01
As noninvasive tests for Helicobacter pylori infection, the 13 C-urea breath test (UBT) and stool antigen test have been widely used. In children, however, there are few studies reporting which test shows superior performance. The purpose of this study was to compare the 13 C-UBT and stool antigen test for their accuracy in diagnosing. H. pylori infection in children. A total of 123 Japanese children, ages 2 to 17 years (mean, 12 years) who underwent gastric biopsies for H. pylori infection were studied. The diagnoses included gastritis (n=55), gastric ulcer (n=5), duodenal ulcer (n=20), iron-deficiency anemia (n=7), and other conditions (n=36). The cutoff value of the 13 C-UBT was defined to be 3.5 per mille. The stool antigen test was performed using the H. pylori stool antigen (HpSA) enzyme-linked immunosorbent assay (ELISA) (Premier Platinum HpSA). In 16 patients who received eradication therapy, the 13 C-UBT and HpSA were repeated 2 months after treatment. Based on biopsy tests, 60 children were infected with H. pylori and 63 children were not. For the 13 C-UBT, the sensitivity, specificity, and accuracy were 95.0% (95% confidence interval [CI], 86.1%-99.0%), 98.4% (95% CI, 91.5%-100%), and 96.4% (95% CI, 93.6%-99.9%), respectively. For the HpSA, the sensitivity, specificity, and accuracy were 983.% (95% CI, 90.8%-100%), 98.4% (95% CI, 91.2%-100%), and 98.3% (95% CI, 96.0%-100%), respectively. There were no significant differences between the performance of these two tests. In the assessment of H. pylori eradication, the results of 13 C-UBT and HpSA agreed with those of biopsy tests. The 13 C-UBT and the HpSA are equally accurate for the diagnosis of active H. pylori infection in Japanese children. (author)
Hønge, Bl; Jespersen, S; Medina, C; Té, Ds; da Silva, Zj; Ostergaard, L; Laursen, Al; Wejse, C; Krarup, H; Erikstrup, C
2014-10-01
In the case of coinfection with HIV and hepatitis B virus (HBV) and/or hepatitis C virus (HCV), hepatic disease progression is often accelerated, with higher rates of liver cirrhosis and liver-related mortality. We aimed to evaluate the performance of the rapid tests used routinely to detect HBV surface antigen (HBsAg) and anti-HCV among HIV-infected patients in Guinea-Bissau. Blood samples from HIV-infected patients in Guinea-Bissau were stored after testing for HBsAg and anti-HCV with rapid tests. Samples were subsequently re-tested for HBsAg and anti-HCV in Denmark. Two rapid tests were used in Guinea-Bissau: HBsAg Strip Ref 2034 (VEDA.LAB, Alençon, France; sensitivity 62.3%; specificity 99.2%) and HEPA-SCAN (Bhat Bio-Tech, Bangalore, India; sensitivity 57.1%; specificity 99.7%). In the two tests the ability to obtain the correct outcome depended on the antigen and antibody concentrations, respectively. Sex, age, CD4 cell count and antiretroviral therapy status did not differ between false negative and true positive samples in either of the tests. The study is limited by a low number of anti-HCV positive samples. New diagnostic rapid tests should always be evaluated in the setting in which they will be used before implementation. © 2014 British HIV Association.
Marjorie S Morgan; S Dean Rider; Larry G Arlian
2017-01-01
Background Scabies, caused by the mite, Sarcoptes scabiei, infects millions of humans, and many wild and domestic mammals. Scabies mites burrow in the lower stratum corneum of the epidermis of the skin and are the source of substances that are antigenic or modulate aspects of the protective response of the host. Ordinary scabies is a difficult disease to diagnose. Objective The goal of this project was to identify S. scabiei proteins that may be candidate antigens for use in a diagnostic test...
Çetiner, Salih; Çetin Duran, Alev; Kibar, Filiz; Yaman, Akgün
2017-06-01
The study has evaluated the performance of HCV core antigen (Cag) test by comparing HCV RNA PCR assay which is considered the gold standard for management of HCV infection. Totally, 132 samples sent for HCV RNA (real-time PCR) test were included in the study. Anti-HCV antibody test and HCV Cag test were performed by chemiluminescent enzyme immunoassay (CMEI). Anti-HCV test was positive in all samples. HCV RNA was detected in 112/132 (84.8%) samples, and HCV Cag in 105/132 (79.5%). The most common HCV genotype was genotype 1 (86%). Considering the HCV RNA test as gold standard; the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of Cag test were found to be 93.75%, 100%, 100%, 74.07% and 94.69%, respectively, and paired test results were detected as highly concordant. A high level of correlation was seen between HCV RNA and Cag tests, however, the concordance between the two tests appeared to be disrupted at viral loads lower than 10 3 IU/mL. On the contrary, the correlation reached significance for the values higher than 10 3 IU/mL. Viral loads were in the 17-2500IU/mL range for the negative results for Cag test. Pearson's correlation coefficient revealed a considerably high correlation. The concordance between HCV RNA and Cag tests was disrupted under a viral load lower than 10 3 IU/mL. Therefore, it would be appropriate to consider cost effectiveness, advantages and limitations of the HCV RNA and Cag tests during the decision on which method to use for patient management. Copyright © 2017 Elsevier Ltd. All rights reserved.
A novel approach for reliable detection of cathepsin S activities in mouse antigen presenting cells.
Steimle, Alex; Kalbacher, Hubert; Maurer, Andreas; Beifuss, Brigitte; Bender, Annika; Schäfer, Andrea; Müller, Ricarda; Autenrieth, Ingo B; Frick, Julia-Stefanie
2016-05-01
Cathepsin S (CTSS) is a eukaryotic protease mostly expressed in professional antigen presenting cells (APCs). Since CTSS activity regulation plays a role in the pathogenesis of various autoimmune diseases like multiple sclerosis, atherosclerosis, Sjögren's syndrome and psoriasis as well as in cancer progression, there is an ongoing interest in the reliable detection of cathepsin S activity. Various applications have been invented for specific detection of this enzyme. However, most of them have only been shown to be suitable for human samples, do not deliver quantitative results or the experimental procedure requires technical equipment that is not commonly available in a standard laboratory. We have tested a fluorogen substrate, Mca-GRWPPMGLPWE-Lys(Dnp)-DArg-NH2, that has been described to specifically detect CTSS activities in human APCs for its potential use for mouse samples. We have modified the protocol and thereby offer a cheap, easy, reproducible and quick activity assay to detect CTSS activities in mouse APCs. Since most of basic research on CTSS is performed in mice, this method closes a gap and offers a possibility for reliable and quantitative CTSS activity detection that can be performed in almost every laboratory. Copyright © 2016. Published by Elsevier B.V.
Alderete, J F
1984-06-01
An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses during the development of lesions in animals inoculated subcutaneously and it reproducibly measured the individual classes immunoglobulins directed at T vaginalis. The colorimetric assay was also suitable for showing cross reactivity between trichomonal species as well as between different strains of T vaginalis. Conditions established for monitoring antibody to trichomanads in immunised rabbits or infected mice were equally effective for human materials, such as serum or vaginal washes. Serum from experimental animals or infected people showed high concentrations of IgG, IgA, and IgM antibody to trichomonads. Only antibodies of the IgG and IgA class were detected in vaginal washes from women with acute trichomoniasis. No IgE antibody to trichomonads was found under a variety of conditions in serum samples from patients or experimental animals.
International Nuclear Information System (INIS)
Klimenkov, A.A.; Tkacheva, G.A.; Gladikov, Yu.V.; Blokhina, N.G.; Ozherel'ev, A.V.
1979-01-01
The results of a dynamic determination of the level of the cancero-embryonic antigen are analysed in 30 patients with stomach neoplasm of the 1-3 stages subjected to a radical operation and 22 patients with stage 4 given polychemotherapy. It is shown that information on the nature of the change in the level of the cancero-embryonal antigen in the blood serves as an important criterion for evaluation of the completeness of the tumour mass removal, detection of the disease relapse and comparison of the efficiency of various combinations of antitumor drugs
Making antigen of trypanosoma evansi and its examination by catt (card agglutination test) method
International Nuclear Information System (INIS)
Arifin, M; Irtisam; Estikoma Dyah; Yulia Ernawati; Boky, J.T
1998-01-01
An experiment was carried out for making antigen (Ag) of T. evansi by using experimental animals rats and guinea pigs for for developing parasites, and in cattle for making immune serum and normal serum. The parasites were irradiated by gamma rays ( 60 Co) at a dose of 300 Gy. The determination of antigen was done by using Card Agglutination Test (CATT) to the field samples serum of cattle. The results obtained showed that antigen was good enough potently and stable at minus 70 0 C storage during five months. (author)
Directory of Open Access Journals (Sweden)
Kazuki Morioka
Full Text Available A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA method was previously developed for foot-and-mouth disease (FMD viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01. In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01. Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.
van den Bos, I. C.; Khanolkar-Young, S.; Das, P. K.; Lockwood, D. N.
1999-01-01
A panel of lipid, carbohydrate and protein antibodies were optimized for use in detecting M. leprae antigens in paraffin embedded material. Skin and nerve biopsies from 13 patients across the leprosy spectrum were studied. All antibodies detected antigen in tissues with a BI > 1. Phenolic-glycolipid
Evaluation of five hepatitis delta virus marker assays for detection of antigen and antibody.
Bezeaud, A; Rosenswajg, M; Guillin, M C
1989-01-01
Five commercially available assays for hepatitis delta (HD) virus markers were compared for sensitivity, specificity, and reproducibility: three assays for antibody (anti-HD), provided by Diagnostics Pasteur, Organon Teknika, and Abbott Laboratories, and two assays for antigen (HD Ag), from Pasteur and Organon Teknika. The assay from Organon Teknika is the less sensitive assay for anti-HD detection. Although the sensitivities of the Pasteur and Abbott assays for anti-HD detection are similar,...
Brownback, Kyle R; Pitts, Lucas R; Simpson, Steven Q
2013-09-01
Diagnosis of invasive pulmonary aspergillosis (IPA) is a challenging process in immunocompromised patients. Galactomannan (GM) antigen detection in bronchoalveolar lavage (BAL) fluid is a method to detect IPA with improved sensitivity over conventional studies. We sought to determine the diagnostic yield of BAL GM assay in a diverse population of immunocompromised patients. A retrospective review of 150 fiberoptic bronchoscopy (FOB) with BAL for newly diagnosed pulmonary infiltrate in immunocompromised patients was performed. Patient information, procedural details and laboratory studies were collected. BAL and serum samples were evaluated for GM using enzyme-linked immunoassay. Of 150 separate FOB with BAL, BAL GM was obtained in 143 samples. There were 31 positive BAL GM assays. In those 31 positive tests, 13 were confirmed as IPA, giving a positive predictive value of 41.9%. There was one false negative BAL GM. Of the 18 false positive BAL GM, 4 were receiving piperacillin-tazobactam and 11 were receiving an alternative beta-lactam antibiotic. BAL GM assay shows excellent sensitivity for diagnosing IPA. There was a significant number of false positive BAL GM assays and several of those patients were receiving beta-lactam antibiotics at the time of bronchoscopy. © 2013 Blackwell Verlag GmbH.
Abou-Elhakam, Hany Mohamed Adel; Bauomy, Ibraheem Rabia; El Deeb, Somaya Osman; El Amir, Azza Mohamed
2013-01-01
Background: Many immunological techniques have been developed over years using the different Fasciola antigens for diagnosis of parasitic infection and to replace the parasitological techniques, which are time consuming and usually lack sensitivity and reproducibility. Materials and Methods: In this study, Fasciola gigantica paramyosin (Pmy) antigen was early detected in cattle sera using sandwich enzyme-linked immunosorbent assay (ELISA), to evaluate the Pmy antigen performance in diagnosis. This work was conducted on 135 cattle blood samples, which were classified according to parasitological investigation into, healthy control (30), fascioliasis (75), and other parasites (30) groups. Results: The sensitivity of Sandwich ELISA was 97.33%, and the specificity was 95%, in comparison with parasitological examination, which recorded 66.66% sensitivity and 100% specificity, respectively. Conclusions: It was clear that the native F. gigantica Pmy is considered as a powerful antigen in early immunodiagnosis of fascioliasis, using a highly sensitive and specific sandwich ELISA technique. PMID:23961441
Kose, Engin; Sirin Kose, Seda; Akca, Deniz; Yildiz, Kerem; Elmas, Cengizhan; Baris, Mustafa; Anil, Murat
2016-08-01
We aimed to investigate the effect of rapid antigen detection test (RADT) in the diagnosis of streptococcal pharyngitis, its impact on antibiotic prescription decision of pediatricians and influence on reduction of antibiotic treatment costs in children with pharyngitis. The study group consisted of 223 patients who were diagnosed with pharyngitis by pediatricians. The sensitivity and specificity of RADT were 92.1% (95% Cl: 78.6-98.3%) and 97.3% (95% Cl: 93.8-99.1%), respectively. In the first assessment, before performing RADT, pediatricians decided to prescribe antibiotics for 178 (79.8%) patients with pharyngitis. After learning RADT results, pediatricians finally decided to prescribe antibiotics for 83 (37.2%) patients with pharyngitis, and antibiotic prescription decreased by 42.6%. Antibiotic costs in non-Group A streptococcus pharyngitis, Group A streptococcus pharyngitis and all subjects groups decreased by 80.8%, 48%, and 76.4%, respectively. Performing RADT in children with pharyngitis has an important impact on treatment decision of clinicians, reduction of unnecessary antibiotic prescriptions and antibiotic costs. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Morgan, Marjorie S.; Rider, S. Dean; Arlian, Larry G.
2017-01-01
Background Scabies, caused by the mite, Sarcoptes scabiei, infects millions of humans, and many wild and domestic mammals. Scabies mites burrow in the lower stratum corneum of the epidermis of the skin and are the source of substances that are antigenic or modulate aspects of the protective response of the host. Ordinary scabies is a difficult disease to diagnose. Objective The goal of this project was to identify S. scabiei proteins that may be candidate antigens for use in a diagnostic test or may be used by the mite to modulate the host’s protective response. Methods An aqueous extract of S. scabiei was separated by 2-dimensional electrophoresis and proteins were identified by mass spectrometry. A parallel immunoblot was probed with serum from patients with ordinary scabies to identify IgM and/or IgG-binding antigens. The genes coding for 23 selected proteins were cloned into E. coli and the expressed recombinant proteins were screened with serum from patients with confirmed ordinary scabies. Results We identified 50 different proteins produced by S. scabiei, 34 of which were not previously identified, and determined that 66% were recognized by patient IgM and/or IgG. Fourteen proteins were screened for use in a diagnostic test but none possessed enough sensitivity and specificity to be useful. Six of the 9 proteins selected for the possibility that they may be immunomodulatory were not recognized by antibodies in patient serum. Conclusions Thirty-three proteins that bound IgM and/or IgG from the serum of patients with ordinary scabies were identified. None of the 14 tested were useful for inclusion in a diagnostic test. The identities of 16 proteins that are not recognized as antigens by infected patients were also determined. These could be among the molecules that are responsible for this mite’s ability to modulate its host’s innate and adaptive immune responses. PMID:28604804
Halpern, Joshua A; Oromendia, Clara; Shoag, Jonathan E; Mittal, Sameer; Cosiano, Michael F; Ballman, Karla V; Vickers, Andrew J; Hu, Jim C
2018-04-01
Guidelines from the NCCN ® (National Comprehensive Cancer Network®) advocate digital rectal examination screening only in men with elevated prostate specific antigen. We investigated the effect of prostate specific antigen on the association of digital rectal examination and clinically significant prostate cancer in a large American cohort. We evaluated the records of the 35,350 men who underwent digital rectal examination in the screening arm of the Prostate, Lung, Colorectal and Ovarian Cancer Screening trial for the development of clinically significant prostate cancer (Gleason 7 or greater). Followup was 343,273 person-years. The primary outcome was the rate of clinically significant prostate cancer among men with vs without suspicious digital rectal examination. We performed competing risks regression to evaluate the interaction between time varying suspicious digital rectal examination and prostate specific antigen. A total of 1,713 clinically significant prostate cancers were detected with a 10-year cumulative incidence of 5.9% (95% CI 5.6-6.2). Higher risk was seen for suspicious vs nonsuspicious digital rectal examination. Increases in absolute risk were small and clinically irrelevant for normal (less than 2 ng/ml) prostate specific antigen (1.5% vs 0.7% risk of clinically significant prostate cancer at 10 years), clinically relevant for elevated (3 ng/ml or greater) prostate specific antigen (23.0% vs 13.7%) and modestly clinically relevant for equivocal (2 to 3 ng/ml) prostate specific antigen (6.5% vs 3.5%). Digital rectal examination demonstrated prognostic usefulness when prostate specific antigen was greater than 3 ng/ml, limited usefulness for less than 2 ng/ml and marginal usefulness for 2 to 3 ng/ml. These findings support the restriction of digital rectal examination to men with higher prostate specific antigen as a reflex test to improve specificity. It should not be used as a primary screening modality to improve sensitivity. Copyright
Energy Technology Data Exchange (ETDEWEB)
Sinyangwe, L N; Munyama, G M; Mubanga, J [Central Veterinary Research Inst. (CVRI), Lusaka (Zambia)
1997-02-01
Antibody and antigen-detection ELISA were used to screen sera originating from a tsetse free area. In addition, bovine samples from tsetse infested areas were analysed using the Buffy Coat Technique (BCT) and the antigen ELISA. Few samples from a negative control population were detected positive resulting in a very good specificity for both tests. When screening a trypanosome infected population the BCT detected more acute and the Ag-ELISA more chronic infections. In conclusion, the antigen ELISA should be used in combination with the BCT, especially in geographical areas where the BCT does not detect any patent infections. (author). 2 refs, 4 figs, 4 tabs.
International Nuclear Information System (INIS)
Sinyangwe, L.N.; Munyama, G.M.; Mubanga, J.
1997-01-01
Antibody and antigen-detection ELISA were used to screen sera originating from a tsetse free area. In addition, bovine samples from tsetse infested areas were analysed using the Buffy Coat Technique (BCT) and the antigen ELISA. Few samples from a negative control population were detected positive resulting in a very good specificity for both tests. When screening a trypanosome infected population the BCT detected more acute and the Ag-ELISA more chronic infections. In conclusion, the antigen ELISA should be used in combination with the BCT, especially in geographical areas where the BCT does not detect any patent infections. (author). 2 refs, 4 figs, 4 tabs
Added value of antigen ELISA in the diagnosis of neurocysticercosis in resource poor settings.
Directory of Open Access Journals (Sweden)
Sarah Gabriël
Full Text Available BACKGROUND: Neurocysticercosis (NCC is the most common cause of acquired epilepsy in Taenia solium endemic areas, primarily situated in low-income countries. Diagnosis is largely based upon the "Del Brutto diagnostic criteria" using the definitive/probable/no NCC diagnosis approach. Neuroimaging and specific T. solium cysticercosis antibody detection results are at the mainstay of this diagnosis, while antigen detection in serum has never been included. This study aimed at evaluating the addition of antigen detection as a major diagnostic criterion, especially in areas where neuroimaging is absent. METHODS: The B158/B60 monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA for the detection of circulating cysticercus antigen was carried out retrospectively on serum samples collected during a hospital-based study from 83 people with epilepsy (PWE in an endemic area. RESULTS: The addition of antigen results as a major criterion allowed the correct diagnosis of definitive NCC in 10 out of 17 patients as opposed to 0/17 without antigen results in the absence of neuroimaging. A sensitivity of 100% and a specificity of 84% were determined for the diagnosis of active NCC using antigen ELISA. While the use of a higher cutoff improves the specificity of the test to 96%, it decreases its sensitivity to 83%. CONCLUSIONS: In areas where neuroimaging is absent, NCC diagnosis according to the existing criteria is problematic. Taking into account its limitations for diagnosis of inactive NCC, antigen detection can be of added value for diagnosing NCC in PWE by supporting diagnostic and treatment decisions. Therefore, we recommend a revision of the "Del Brutto diagnostic criteria" for use in resource poor areas and suggest the inclusion of serum antigen detection as a major criterion.
Turgeon, David K; Novicki, Thomas J; Quick, John; Carlson, LaDonna; Miller, Pat; Ulness, Bruce; Cent, Anne; Ashley, Rhoda; Larson, Ann; Coyle, Marie; Limaye, Ajit P; Cookson, Brad T; Fritsche, Thomas R
2003-02-01
Clostridium difficile is one of the most frequent causes of nosocomial gastrointestinal disease. Risk factors include prior antibiotic therapy, bowel surgery, and the immunocompromised state. Direct fecal analysis for C. difficile toxin B by tissue culture cytotoxin B assay (CBA), while only 60 to 85% sensitive overall, is a common laboratory method. We have used 1,003 consecutive, nonduplicate fecal samples to compare six commercially available immunoassays (IA) for C. difficile detection with CBA: Prima System Clostridium difficile Tox A and VIDAS Clostridium difficile Tox A II, which detect C. difficile toxin A; Premier Cytoclone A/B and Techlab Clostridium difficile Tox A/B, which detect toxins A and B; and ImmunoCard Clostridium difficile and Triage Micro C. difficile panels, which detect toxin A and a species-specific antigen. For all tests, Triage antigen was most sensitive (89.1%; negative predictive value [NPV] = 98.7%) while ImmunoCard was most specific (99.7%; positive predictive value [PPV] = 95.0%). For toxin tests only, Prima System had the highest sensitivity (82.2%; NPV = 98.0%) while ImmunoCard had the highest specificity (99.7%; PPV = 95.0%). Hematopoietic stem cell transplant (HSCT) patients contributed 44.7% of all samples tested, and no significant differences in sensitivity or specificity were noted between HSCT and non-HSCT patients. IAs, while not as sensitive as direct fecal CBA, produce reasonable predictive values, especially when both antigen and toxin are detected. They also offer significant advantages over CBA in terms of turnaround time and ease of use.
Photopatch and UV-irradiated patch testing in photosensitive dermatitis
Directory of Open Access Journals (Sweden)
Reena Rai
2016-01-01
Full Text Available Background: The photopatch test is used to detect photoallergic reactions to various antigens such as sunscreens and drugs. Photosensitive dermatitis can be caused due to antigens like parthenium, fragrances, rubbers and metals. The photopatch test does not contain these antigens. Therefore, the Indian Standard Series (ISS along with the Standard photopatch series from Chemotechnique Diagnostics, Sweden was used to detect light induced antigens. Aim: To detect light induced antigens in patients with photosensitive dermatitis. Methods: This study was done in a descriptive, observer blinded manner. Photopatch test and ISS were applied in duplicate on the patient's back by the standard method. After 24 hours, readings were recorded according to ICDRG criteria. One side was closed and other side irradiated with 14 J/cm2 of UVA and a second set of readings were recorded after 48 hrs. Result: The highest positivity was obtained with parthenium, with 18 out of 35 (51% patients showing a positive patch test reaction with both photoallergic contact dermatitis and photoaggravation. Four patients (11% showed positive patch test reaction suggestive of contact dermatitis to potassium dichromate and fragrance mix. Six patients had contact dermatitis to numerous antigens such as nickel, cobalt, chinoform and para-phenylenediamine. None of these patients showed photoaggravation on patch testing. Conclusion: Parthenium was found to cause photoallergy, contact dermatitis with photoaggravation and contact allergy. Hence, photopatch test and UV irradiated patch test can be an important tool to detect light induced antigens in patients with photosensitive dermatitis.
ELISA for detection of variant rabbit haemorrhagic disease virus RHDV2 antigen in liver extracts.
Dalton, K P; Podadera, A; Granda, V; Nicieza, I; Del Llano, D; González, R; de Los Toyos, J R; García Ocaña, M; Vázquez, F; Martín Alonso, J M; Prieto, J M; Parra, F; Casais, R
2018-01-01
The emergence and rapid spread of variant of the rabbit hemorrhagic disease virus (RHDV2) require new diagnostic tools to ensure that efficient control measures are adopted. In the present study, a specific sandwich enzyme-linked immunosorbent assay (ELISA) for detection of RHDV2 antigens in rabbit liver homogenates, based on the use of an RHDV2-specific monoclonal antibody (Mab) 2D9 for antigen capture and an anti-RHDV2 goat polyclonal antibody (Pab), was developed. This ELISA was able to successfully detect RHDV2 and RHDV2 recombinant virions with high sensitivity (100%) and specificity (97.22%). No cross-reactions were detected with RHDV G1 viruses while low cross-reactivity was detected with one of the RHDVa samples analyzed. The ELISA afforded good repeatability and had high analytical sensitivity as it was able to detect a dilution 1:163,640 (6.10ng/mL) of purified RHDV-N11 VLPs, which contained approximately 3.4×10 8 molecules/mL particles. The reliable discrimination between closely related viruses is crucial to understand the epidemiology and the interaction of co-existing pathogens. In the work described here we design and validate an ELISA for laboratory based, specific, sensitive and reliable detection of RHDVb/RHDV2. This ELISA is a valuable, specific virological tool for monitoring virus circulation, which will permit a better control of this disease. Copyright © 2017 Elsevier B.V. All rights reserved.
False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.
Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W
2011-02-01
A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.
Energy Technology Data Exchange (ETDEWEB)
Saleem, Iram, E-mail: iiram.qau@gmail.com [Department of Physics and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Widger, William, E-mail: widger@uh.edu [Department of Biology and Biochemistry and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Chu, Wei-Kan, E-mail: wkchu@uh.edu [Department of Physics and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States)
2017-07-31
Highlights: • The nano ripple LSPR chip has monolayer molecule-coating sensitivity and specific selectivity. • Gold nano-ripple sensing chip is a low cost, and a label-free method for detecting the antibody-antigen reaction. • The plasmonic resonance shift depends upon the concentration of the biomolecules attached on the surface of the nano ripple pattern. - Abstract: We demonstrate that the gold nano-ripple localized surface plasmon resonance (LSPR) chip is a low cost and a label-free method for detecting the presence of an antigen. A uniform stable layer of an antibody was coated on the surface of a nano-ripple gold pattern chip followed by the addition of different concentrations of the antigen. A red shift was observed in the LSPR spectral peak caused by the change in the local refractive index in the vicinity of the nanostructure. The LSPR chip was fabricated using oblique gas cluster ion beam (GCIB) irradiation. The plasmon-resonance intensity of the scattered light was measured by a simple optical spectroscope. The gold nano ripple chip shows monolayer scale sensitivity and high selectivity. The LSPR substrate was used to detect antibody-antigen reaction of rabbit X-DENTT antibody and DENTT blocking peptide (antigen).
Athanasiou, Labrini V; Kantere, Maria C; Kyriakis, Constantinos S; Pardali, Dimitra; Adamama Moraitou, Katerina; Polizopoulou, Zoe S
2018-04-01
Canine distemper is a common and potentially lethal multisystemic disease caused by the Canine distemper virus (CDV). We evaluated the diagnostic performance of direct immunofluorescent assay (FA) and cytology to detect CDV antigen in conjunctival cells compared with an established polymerase chain reaction (PCR) detection assay used as a gold standard for CDV diagnosis. Samples were collected from 57 young dogs presenting with central nervous system signs compatible with distemper disease. Exfoliative epithelial cells were collected from the right and left conjunctiva of each animal using nylon-bristled cytobrushes for cytology and cotton swabs for FA and PCR. For the direct FA, samples were stained with anti-CDV polyclonal antiserum conjugated to fluorescein isothiocyanate and imaged using a fluorescent microscope. Out of 57 dogs tested, 19 were PCR positive (15 positive in direct FA and 4 positive in cytology, including one that was negative by PCR), whereas 37 dogs were negative in all methods. A good agreement was observed between the FA and PCR, with a κ-value of 0.833 (95% CI: 0.678-0.989). Meanwhile, there was poor agreement between cytology and PCR (κ-value of 0.164; 95% CI: -0.045 to 0.373) and a fair agreement between FA and cytology (κ-value of 0.231; 95% CI: -0.026 to 0.487). Our results indicated a poor performance of cytology for the detection of CDV antigen. In contrast, FA is a 100% specific and an adequately sensitive assay (sensitivity: 78.95%, negative likelihood ratio: 0.21, 95% CI: 0.09-0.50) for antemortem diagnosis of canine distemper.
Attallah, Abdelfattah M; Bughdadi, Faisal A; El-Shazly, Atef M; Ismail, Hisham
2013-10-01
Currently, the laboratory diagnosis of human fascioliasis is based on the parasitological examination of parasite eggs in stool specimens and serological detection of specific antibodies in serum samples, which are often unreliable diagnostic approaches. Ideally, a sensitive and specific diagnostic test for Fasciola infection should be based on the detection of circulating Fasciola antigen, which implies active infection. Here, a 27-kDa-molecular-mass antigen was identified in a Fasciola gigantica adult worm antigen preparation, excretory-secretory products, and sera from F. gigantica-infected individuals, and it was not detected in antigenic extracts of other parasites and sera from noninfected individuals. The target antigen was isolated and partially characterized as a protein. Immunoperoxidase staining located the target epitope within teguments and guts of F. gigantica adult worms. The performance characteristics of a newly developed enzyme-linked immunosorbent assay (ELISA) based on F. gigantica circulating antigen detection in serum (FgCA-27 ELISA) were investigated using sera of 120 parasitologically diagnosed F. gigantica-infected individuals and 80 noninfected individuals. The area under the receiving operating characteristic (ROC) curve (AUC) for ELISA was significantly high (AUC = 0.961, P 93%), and a significant correlation (r = 0.715, P fascioliasis.
False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿
Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.
2011-01-01
A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939
DEFF Research Database (Denmark)
Mikkelsen, Heidi; Aagaard, Claus; Nielsen, Søren Saxmose
2012-01-01
of the study were to evaluate immunogenicity and specificity of 14 novel recombinant antigens for use in the IFN-γ assay and to assess the consistency of IFN-γ responses. The antigens used were 4 ESAT-6 family members, 4 latency proteins, 4 secreted proteins including Ag85B, 3 other antigens and PPDj......Early stage Mycobacterium avium subsp. paratuberculosis (MAP) infection can be detected by measuring antigen specific cell mediated immune responses by the interferon gamma (IFN-γ) assay. Available IFN-γ assay use purified protein derivate of Johnin (PPDj) leading to low specificity. The objectives...... of the infected and non-infected herds were significantly (Passay using PPDj did not correlate with the results using the novel antigens since 5 of the 17 animals that were positive to PPDj were...
Filella, Xavier; Foj, Laura
2016-10-26
Prostate specific antigen (PSA) remains the most used biomarker in the management of early prostate cancer (PCa), in spite of the problems related to false positive results and overdiagnosis. New biomarkers have been proposed in recent years with the aim of increasing specificity and distinguishing aggressive from non-aggressive PCa. The emerging role of the prostate health index and the 4Kscore is reviewed in this article. Both are blood-based tests related to the aggressiveness of the tumor, which provide the risk of suffering PCa and avoiding negative biopsies. Furthermore, the use of urine has emerged as a non-invasive way to identify new biomarkers in recent years, including the PCA3 and TMPRSS2:ERG fusion gene. Available results about the PCA3 score showed its usefulness to decide the repetition of biopsy in patients with a previous negative result, although its relationship with the aggressiveness of the tumor is controversial. More recently, aberrant microRNA expression in PCa has been reported by different authors. Preliminary results suggest the utility of circulating and urinary microRNAs in the detection and prognosis of PCa. Although several of these new biomarkers have been recommended by different guidelines, large prospective and comparative studies are necessary to establish their value in PCa detection and prognosis.
Solaymani-Mohammadi, Shahram; Rezaian, Mostafa; Babaei, Zahra; Rajabpour, Azam; Meamar, Ahmad R; Pourbabai, Ahmad A; Petri, William A
2006-06-01
The present study was conducted to compare stool antigen detection with PCR for the diagnosis of Entamoeba sp. infection in asymptomatic cyst passers from Iran. Entamoeba dispar and, in one case, E. moshkovskii were the Entamoeba spp. found in the amebic cyst passers. There was a 100% correlation between the results from the TechLab E. histolytica II stool antigen kit and those from nested PCR. We concluded that E. dispar is much more common in asymptomatic cyst passers in Iran and that antigen detection and PCR are comparable diagnostic modalities.
Multianalyte Tests for the Early Detection of Cancer: Speedbumps and Barriers
Directory of Open Access Journals (Sweden)
Michael A. Tainsky
2007-01-01
Full Text Available It has become very clear that a single molecular event is inadequate to accurately predict the biology (or pathophysiology of cancer. Furthermore, using any single molecular event as a biomarker for the early detection of malignancy may not comprehensively identify the majority of individuals with that disease. Therefore, the fact that technologies have arisen that can simultaneously detect several, possibly hundreds, of biomarkers has propelled the field towards the development of multianalyte-based in vitro diagnostic early detection tests for cancer using body fl uids such as serum, plasma, sputum, saliva, or urine. These multianalyte tests may be based on the detection of serum autoantibodies to tumor antigens, the presence of cancer-related proteins in serum, or the presence of tumor-specific genomic changes that appear in plasma as free DNA. The implementation of non-invasive diagnostic approaches to detect early stage cancer may provide the physician with evidence of cancer, but the question arises as to how the information will affect the pathway of clinical intervention. The confirmation of a positive result from an in vitro diagnostic cancer test may involve relatively invasive procedures to establish a true cancer diagnosis. If in vitro diagnostic tests are proven to be both specific, i.e. rarely produce false positive results due to unrelated conditions, and sufficiently sensitive, i.e. rarely produce false negative results, then such screening tests offer the potential for early detection and personalized therapeutics using multiple disease-related targets with convenient and non-invasive means. Here we discuss the technical and regulatory barriers inherent in development of clinical multianalyte biomarker assays.
DEFF Research Database (Denmark)
Liu, Jiayou; Schnyder, Manuela; Willesen, Jakob L.
2017-01-01
of the Angio Detect test kit by comparing Angio Detect testing results using serum or plasma samples with the results of Baermann-Wetzel testing using matched fecal samples. Samples from 214 dogs [with clinically suspected (N = 195) or diagnosed angiostrongylosis (N = 19)] were used for this evaluation......; sensitivity of the Angio Detect test was 97.1% (95%CI: 85.1%–99.9%). The Angio Detect test was negative for 177 of 179 samples that were negative by the Baermann-Wetzel test; specificity was 98.9% (95%CI: 96.0%–99.9%). In cross-reactivity testing, all 89 samples from dogs confirmed to be infected with other...... common nematodes (Dirofilaria immitis, D. repens, Crenosoma vulpis, hookworms, ascarids, or whipworms) were all negative for A. vasorum by the Angio Detect antigen test. Angio Detect provides a rapid and reliable method for diagnosis of A. vasorum in clinically suspected dogs at risk for infection...
A simple assay for the detection of antibodies to endocrine islet cell surface antigens
International Nuclear Information System (INIS)
Contreas, G.; Madsen, O.D.; Vissing, H.; Lernmark, Aa.
1986-01-01
A simple and sensitive immunoradiometric assay for the detection of islet cell surface antibodies (CIRMA) has been developed. Live, transformed islet cells derived from a liver metastasis of a transplantable islet cell tumor were grown in removable microtiter wells and incubated with antibody. Cell-bound antibodies were quantitated using 125 I-labelled second antibodies. The assay was used to detect islet cell antibodies present in sera from non-diabetic and diabetic BB rats and proved to be particularly effective for screening hybridoma supernatants in order to identify monoclonal antibodies recognizing islet cell surface antigens. (Auth.)
Directory of Open Access Journals (Sweden)
Rodríguez-Osorio M.
2003-06-01
Full Text Available A third outbreak of Trichinella britovi with 140 people involved, occurred in Granada Spain (December 1998. The source of infection was sausage made from uninspected wild boar meat. Fifty-two patients agreed to participated in this study. An elevated eosinophil level (> 5 % was detected in 59.6 % of patients, and persisted in most of these cases for two months. A moderate IgG response was observed. At the onset of symptoms, Western blot (WB test detected more positive cases than Enzyme linked immunosorbent assay (ELISA and indirect immunofluorescence (IIF. Six months from infection, ELISA revealed fewer positive cases than the other two tests. It would appear that the response to somatic antigens starts earlier than those to cuticular and excretory/secretory (ES antigens and that the response to ES antigens is the first to decrease.
Japhet, Margaret Oluwatoyin; Adewumi, Moses Olubusuyi; Adesina, Olufisayo Adeyemi; Donbraye, Emmanuel
2016-01-01
Blood transfusion service centers in Nigeria screen donated blood for markers of HIV infection using antibody- (Ab) based rapid test and in some centers, positives are re-tested using Ab-based ELISA. Paucity of data exists on p24 antigen prevalence among HIV Ab-negative donors in Nigeria. This study aims at detecting HIV p24 antigen among prospective blood donors in Osun State, Nigeria. Prospective blood donors negative for HIV antibodies using Determine test kit were re-tested using BIORAD GENSCREEN Ultra Ag-Ab ELISA kit, a fourth-generation ELISA kit that detects HIV antibodies/p24 antigen. Of the 169 HIV Ab-negative prospective donors, 10 (5.9%) were positive for HIV p24 antigen and 70% (7/10) of them were in the age range 18-30 years. Results of this study show that blood transfusion is still one of the major routes of HIV transmission in Nigeria and a higher proportion is among youth. Inclusion of p24 antigen testing into the blood donor screening will help reduce transfusion associated HIV in Nigeria if Nucleic Acid Testing (NAT) of all blood donor samples is not affordable; also, HIV enlightenment programs tailored toward youth may help reduce this rate among donors since more young people donate blood in low/middle-income countries than in high-income countries.
Pascho, Ronald J.; Chase, Dorothy M.; McKibben, Constance L.
1998-01-01
Ovarian fluid samples from naturally infected chinook salmon (Oncorhynchus tshawytscha) were examined for the presence of Renibacterium salmoninarum by the membrane-filtration fluorescent antibody test (MF-FAT), an antigen capture enzyme-linked immunosorbent assay (ELISA), and a nested polymerase chain reaction (PCR). On the basis of the MF-FAT, 64% (66/103) samples contained detectable levels of R. salmoninarum cells. Among the positive fish, the R. salmoninarum concentrations ranged from 25 cells/ml to 4.3 × 109cells/ml. A soluble antigenic fraction of R. salmoninarum was detected in 39% of the fish (40/103) by the ELISA. The ELISA is considered one of the most sensitive detection methods for bacterial kidney disease in tissues, yet it did not detect R. salmoninarum antigen consistently at bacterial cell concentrations below about 1.3 × 104cells/ml according to the MF-FAT counts. When total DNA was extracted and tested in a nested PCR designed to amplify a 320-base-pair region of the gene encoding a soluble 57-kD protein of R. salmoninarum, 100% of the 100 samples tested were positive. The results provided strong evidence that R. salmoninarum may be present in ovarian fluids thought to be free of the bacterium on the basis of standard diagnostic methods.
Choong, Yee Siew; Lim, Theam Soon; Chew, Ai Lan; Aziah, Ismail; Ismail, Asma
2011-04-01
The high typhoid incidence rate in developing and under-developed countries emphasizes the need for a rapid, affordable and accessible diagnostic test for effective therapy and disease management. TYPHIDOT®, a rapid dot enzyme immunoassay test for typhoid, was developed from the discovery of a ∼50 kDa protein specific for Salmonella enterica serovar Typhi. However, the structure of this antigen remains unknown till today. Studies on the structure of this antigen are important to elucidate its function, which will in turn increase the efficiency of the development and improvement of the typhoid detection test. This paper described the predictive structure and function of the antigenically specific protein. The homology modeling approach was employed to construct the three-dimensional structure of the antigen. The built structure possesses the features of TolC-like outer membrane protein. Molecular docking simulation was also performed to further probe the functionality of the antigen. Docking results showed that hexamminecobalt, Co(NH(3))(6)(3+), as an inhibitor of TolC protein, formed favorable hydrogen bonds with D368 and D371 of the antigen. The single point (D368A, D371A) and double point (D368A and D371A) mutations of the antigen showed a decrease (single point mutation) and loss (double point mutations) of binding affinity towards hexamminecobalt. The architecture features of the built model and the docking simulation reinforced and supported that this antigen is indeed the variant of outer membrane protein, TolC. As channel proteins are important for the virulence and survival of bacteria, therefore this ∼50 kDa channel protein is a good specific target for typhoid detection test. Copyright © 2011 Elsevier Inc. All rights reserved.
Variation in general practice prostate-specific antigen testing and prostate cancer outcomes
DEFF Research Database (Denmark)
Hjertholm, Peter; Fenger-Grøn, Morten; Vestergaard, Mogens
2015-01-01
Brugen af prostata-specifikt antigen (PSA) er mangedoblet i dansk almen praksis siden introduktionen i 1990’erne. Dansk Urologisk Selskab anbefaler brug af testen ved relevante symptomer og arvelig disposition, men ikke til screening. Alligevel varierer brugen af PSA-tests i almen praksis. Dette...
International Nuclear Information System (INIS)
Rodak, L.
1975-01-01
An autoradiographic method for detecting soluble antigen (chicken serum albumin, CSA) and specific antibodies in the spleen of rabbits during a primary immune response is described. The method consists of incubating sections from the spleen with 125 I-labelled IgG 2 anti CSA (for demonstration of antigen) or with 125 I-labelled antigen (for demonstration of specific antibodies). This treatment of histological sections combines the advantages and principles of the immunofluorescence technique with the possibility of evaluating the exact localization of the proteins by light microscopy in preparations stained with haematoxylin or methyl green-pyronin. The sensitivity of detection is very high: both antigen and antibodies could be demonstrated in the spleen follicles for as long as 42 days after the primary intravenous injection
Directory of Open Access Journals (Sweden)
Rafaella Fortini Queiroz Grenfell
2012-08-01
Full Text Available INTRODUCTION: The correlation between the immunological assay and the antibody titer can offer a tool for the experimental analysis of different phases of the disease. METHODS: Two simple immunological assays for Schistosoma mansoni in mice sera samples based on specific IgG detection for worms soluble antigens and eggs soluble antigens were standardized and evaluated in our laboratory. Fifty mice were used in negative and positive groups and the results obtained by enzyme-linked immunosorbent assays (ELISA assays were compared with the number of worms counted and the IgG titers at different times of infection. RESULTS: Data showed that ELISA using adult worm antigens (ELISA-SWAP presented a satisfactory correlation between the absorbance value of IgG titers and the individual number of worms counted after perfusion technique (R²=0.62. In addition, ELISA-SWAP differentially detected positive samples with 30 and 60 days post infection (p=0.011 and 0.003, respectively, whereas ELISA using egg antigens (ELISA-SEA detected samples after 140 days (p=0.03. CONCLUSIONS: These data show that the use of different antigens in immunological methods can be used as potential tools for the analysis of the chronological evolution of S. mansoni infection in murine schistosomiasis. Correlations with human schistosomiasis are discussed.
Validation of pre-coated ELISA tests to detect antibodies against T. congolense and T. vivax
International Nuclear Information System (INIS)
Shumba, W.
2000-01-01
The anti-trypanosomal antibody detecting enzyme linked immunosorbent assay (ELISA) was first described in 1977 and was further developed for use in large scale surveys in Zimbabwe. More recently, the IAEA initiated a programme to improve the robustness and standardisation of the assay. The IAEA supplied plates pre-coated with either a crude T. congolense or T. vivax antigen and the reagents necessary for analysing samples. Parasitologically positive and negative sera were used to validate and determine the cut-off values of the two tests. The samples were tested and results analysed using a variety of cut-off values. The tests provided similar information although the T. congolense pre-coated plates gave significantly higher optical density values than the plates coated with T. vivax. Sensitivity and specificity values were calculated using the different cut-off points. Results indicate that the test using T. congolense antigen had the highest specificity and sensitivity for a given cut-off value. Although the test could distinguish positive from negative sera, it was quite difficult to provide a suitable cut-off value, but the value should be dictated by the use of the test. (author)
Waitumbi, John N; Gerlach, Jay; Afonina, Irina; Anyona, Samuel B; Koros, Joseph N; Siangla, Joram; Ankoudinova, Irina; Singhal, Mitra; Watts, Kate; Polhemus, Mark E; Vermeulen, Nicolaas M; Mahoney, Walt; Steele, Matt; Domingo, Gonzalo J
2011-07-01
To determine the malaria prevalence by microscopy, antigen detection and nucleic acid detection in a defined subpopulation in a Plasmodium falciparum-endemic region during the peak transmission season. Blood specimens were collected in a cross-sectional study involving children aged 5-10 years (n = 195) presenting with acute fever to two clinics in Western Kenya. All specimens underwent microscopy, HRP2 and aldolase antigen detection by enzyme immunoassay (EIA), parasite-specific DNA and total nucleic acid (RNA and DNA) by real-time PCR (qPCR) and reverse-transcriptase PCR (qRT-PCR). Microscopy detected 65/195 cases of malaria infection [95% confidence interval (CI) 52-78]. HRP2 and aldolase EIA had similar sensitivity levels detecting antigen in 65/195 (95% CI, 52-78) and 57/195 (95% CI, 45-70) cases. Discordants in antigen detection vs. microscopy occurred at Detection of total nucleic acid allowed a 3 log lower limit of detection than just DNA detection by real-time PCR in vitro. In clinical specimens, 114/195 (95% CI, 100-127) were qPCR positive (DNA), and 187/195 (95% CI, 179-191) were qRT-PCR positive (DNA plus RNA). The prevalence of submicroscopic malaria infection was significantly higher when detecting total nucleic acid than just DNA in this outpatient population during the high transmission season. Defining standards for submicroscopic infection will be important for control programmes, diagnostics development efforts and molecular epidemiology studies. © 2011 Blackwell Publishing Ltd.
Aranda, Lorena I; Smith, Linda A; Jones, Scott; Beddard, Rachel
2015-01-01
Alloimmunization to red blood cell antigens is seen in patients receiving chronic blood transfusion. Knowing the prevalence of blood group antigens of the different ethnicities of South Texas donors can provide better management of rare blood inventory for patients in this geographical area. A total of 4369 blood donors were tested and analyzed for various antigens in the following blood group systems: ABO, Rh, Kell, Duffy, Kidd, MNS, Lutheran, Dombrock, Landsteiner-Wiener, Diego, Colton, and Scianna. Donors tested to be group 0 or A were serologically tested for the Rh (C, E, c, e) antigens. Those that tested as presumably R1R1, R2R2, or Ror were then genotyped. Donors constituted three major ethnicities: black (18.3%), Hispanic (36.3%), and Caucasian (41.1%); ethnicities comprised of Asian, American Indian, multiracial, and other accounted for the remaining donors (4.3%). The most likely common Rh phenotype for each ethnicity is as follows: black -Ror (44.4%), Hispanic -R1R1 (59.0%), and Caucasian -R1R1 (38.9%). The prevalence of Kell, Duffy, and Kidd blood group system antigens in black and Caucasian donors is comparable with published reports for the entire U.S. The black South Texas donor population had an 8.8 percent increase in prevalence of the Fy(a+b-) phenotype as compared with these published reports; the Hispanic South Texas donor population had a prevalence of 36.1 percent of the Fy(a+b-) phenotype. Regarding the Diego blood group system, the Hispanic donor population in South Texas had a prevalence of 93.5 percent for the Di(a-b+) phenotype as compared with published reports for the entire U.S. (>99.9%). The Hispanic population had a prevalence of 7.9 percent of donors testing as M-N+S-s+ as compared with 20.2 percent and 15.6 percent for black and Caucasian donors, respectively. This study helped us determine the prevalence of each of the blood group antigens in the South Texas donor population to establish and maintain adequate rare inventory of
Moreno, Elizabeth Castro; Gonçalves, Andréa Vieira; Chaves, Anderson Vieira; Melo, Maria Norma; Lambertucci, José Roberto; Andrade, Antero Silva Ribeiro; Negrão-Corrêa, Deborah; Antunes, Carlos Mauricio de Figueiredo; Carneiro, Mariângela
2009-01-01
Background One of the most important drawbacks in visceral leishmaniasis (VL) population studies is the difficulty of diagnosing asymptomatic carriers. The aim of this study, conducted in an urban area in the Southeast of Brazil, was to evaluate the performance of serology to identify asymptomatic VL infection in participants selected from a cohort with a two-year follow-up period. Methodology Blood samples were collected in 2001 from 136 cohort participants (97 positive and 39 negatives, PCR/hybridization carried out in 1999). They were clinically evaluated and none had progressed to disease from their asymptomatic state. As controls, blood samples from 22 control individuals and 8 patients with kala-azar were collected. Two molecular biology techniques (reference tests) were performed: PCR with Leishmania-generic primer followed by hybridization using L. infantum probe, and PCR with specific primer to L. donovani complex. Plasma samples were tested by ELISA using three different antigens: L. infantum and L. amazonensis crude antigens, and rK39 recombinant protein. Accuracy of the serological tests was evaluated using sensitivity, specificity, likelihood ratio and ROC curve. Findings The presence of Leishmania was confirmed, by molecular techniques, in all kala-azar patients and in 117 (86%) of the 136 cohort participants. Kala-azar patients showed high reactivity in ELISAs, whereas asymptomatic individuals presented low reactivity against the antigens tested. When compared to molecular techniques, the L. amazonensis and L. infantum antigens showed higher sensitivity (49.6% and 41.0%, respectively) than rK39 (26.5%); however, the specificity of rK39 was higher (73.7%) than L. amazonensis (52.6%) and L. infantum antigens (36.8%). Moreover, there was low agreement among the different antigens used (kappa<0.10). Conclusions Serological tests were inaccurate for diagnosing asymptomatic infections compared to molecular methods; this could lead to misclassification bias
Ali, Amjad; Nisar, Muhammad; Idrees, Muhammad; Rafique, Shazia; Iqbal, Muhammad
2015-05-01
Early diagnosis of HCV infection is based on detection of antibodies against HCV proteins using recombinant viral antigens. The present study was designed to select, clone and express the antigenic regions of Core and E2 genes from local HCV-3a genotype and to utilize the antigenic recombinant proteins (Core & E2) to develop highly sensitive, specific and economical diagnostic assays for detection of HCV infection. The antigenic sites were determined within Core and E2 genes and were then cloned in pET-28a expression vector. The right orientation of the desired inserted fragments of Core and E2 were confirmed via sequencing prior to expression and were then transformed in BL21 (DE3) pLysS strains of E. coli and induced with 0.5mM Isopropyl-b-D-thiogalactopyranoside (IPTG) for the production of antigenic recombinant proteins. The produced truncated antigens were then purified by Nickel affinity chromatography and were confirmed by western blotting, immunoblotting and enzyme-linked immunosorbent assay (ELISA). The expressed Core and E2 recombinant antigens were used to develop immunoblotting assay for the detection of anti-HCV antibodies in sera. With immunoblotting, a total of 93-HCV infected sera and 35-HCV negative individuals were tested for the presence of anti-HCV antibodies to the Core and E2 antigens. Recombinant antigen showed 100% reactivity against HCV infected sera, with no cross reactivity against HCV-negative sera. The immunoblot assay mixture of recombinant antigens (Core+E2) showed a strong reaction intensity in the test area (TA) as compared to the individual truncated Core and E2 recombinant antigens. In the in-house ELISA assay, mixed Core and E2 recombinant antigens showed 100% reactivity against a standardized panel of 150-HCV-positive sera and non reactivity against a standardized panel of 150 HCV-negative sera while also being non reactive to sera positive for other viral infections. The antigenic recombinant antigens also were tested for the
Energy Technology Data Exchange (ETDEWEB)
Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A
1984-05-01
Specifications have been elaborated for formulating indirect solid-phase enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (SPRIA) methods that employ anti-human and anti-mice G class immunoglobulin (IgG), conjugated with horseradish peroxidase and /sup 125/I for detecting the arenaviruses Junin, Machupo, Tacaribe, Amalpari, Tamiami, Lassa, and LCM (lymphocytic choriomeningitis). These methods make it possible to identify with a high degree of sensitivity arenavirus antigens and antibodies in various kinds of material.
Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N.; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E.; Garcia, Hector H.; Gilman, Robert H.; Tsang, Victor C. W.; Wilkins, Patricia P.
2010-01-01
One of the best-characterized tests for the diagnosis of neurocysticercosis is the enzyme-linked immunoelectrotransfer blot assay, developed at the CDC, which uses lentil lectin-purified glycoproteins (LLGPs) extracted from Taenia solium cysticerci. The purification of the LLGP antigens has been difficult to standardize, and the polyacrylamide gel system used for the immunoblot assay is not easily transferable to other laboratories. In this study, we developed a multiantigen printing immunoassay (MAPIA) to compare the performance of multiple recombinant Taenia solium proteins with the potential for the detection of cysticercosis and taeniasis. We prepared MAPIA strips using six cysticercosis and two taeniasis diagnostic proteins and compared the performance of the proteins with sera collected from defined cysticercosis and taeniasis cases. Of the six cysticercosis antigens, rT24H performed well in detecting cases with two or more viable cysts in the brain (sensitivity and specificity, 97% and 99.4%, respectively); the use of a combination of cysticercosis antigens did not improve the sensitivity of the test and decreased the specificity. None of the antigens could differentiate the different clinical presentations of cysticercosis. Both of the taeniasis antigens (rES33 and rES38) had the same sensitivity of 99.4% and specificities of 93.9% and 94.5%, respectively. Some cross-reactivity against rES33 and rES38 was found, especially with sera from cases infected with Schistosoma mansoni. We conclude that MAPIA is a simple and effective tool that may be used to compare antibody responses to different cysticercosis and taeniasis antigens and, in this case, may be useful for the rapid detection of T. solium cases. PMID:19906893
Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E; Garcia, Hector H; Gilman, Robert H; Tsang, Victor C W; Wilkins, Patricia P
2010-01-01
One of the best-characterized tests for the diagnosis of neurocysticercosis is the enzyme-linked immunoelectrotransfer blot assay, developed at the CDC, which uses lentil lectin-purified glycoproteins (LLGPs) extracted from Taenia solium cysticerci. The purification of the LLGP antigens has been difficult to standardize, and the polyacrylamide gel system used for the immunoblot assay is not easily transferable to other laboratories. In this study, we developed a multiantigen printing immunoassay (MAPIA) to compare the performance of multiple recombinant Taenia solium proteins with the potential for the detection of cysticercosis and taeniasis. We prepared MAPIA strips using six cysticercosis and two taeniasis diagnostic proteins and compared the performance of the proteins with sera collected from defined cysticercosis and taeniasis cases. Of the six cysticercosis antigens, rT24H performed well in detecting cases with two or more viable cysts in the brain (sensitivity and specificity, 97% and 99.4%, respectively); the use of a combination of cysticercosis antigens did not improve the sensitivity of the test and decreased the specificity. None of the antigens could differentiate the different clinical presentations of cysticercosis. Both of the taeniasis antigens (rES33 and rES38) had the same sensitivity of 99.4% and specificities of 93.9% and 94.5%, respectively. Some cross-reactivity against rES33 and rES38 was found, especially with sera from cases infected with Schistosoma mansoni. We conclude that MAPIA is a simple and effective tool that may be used to compare antibody responses to different cysticercosis and taeniasis antigens and, in this case, may be useful for the rapid detection of T. solium cases.
Identification of toxocara canis antigens by Western blot in experimentally infected rabbits
Directory of Open Access Journals (Sweden)
MORALES Olga Lucía
2002-01-01
Full Text Available Toxocariasis is a frequent helminthiasis that can cause visceral and ocular damage in humans specially in children. The identification of specific antigens of Toxocara canis is important in order to develop better diagnostic techniques. Ten rabbits were infected orally with a dose of 5000 Toxocara canis embryonated eggs. Rabbits were bled periodically and an ELISA assay was performed to determine levels of specific Toxocara IgG antibodies. ELISA detected antibodies at day 15 after infection. Western blot (WB assay was performed using excretory/secretory antigens (E/S of T. canis second stage larvae. Different antigen concentrations were evaluated: 150, 200, 250 and 300 µg/mL. The concentration of 250 µg/mL was retained for analysis. Rabbit sera were diluted 1:100. Secondary antibody was used at a dilution of 1:1000. Results of WB indicated that in the first month after infection specific antibodies against the 200 KDa, 116 KDa, 92 KDa and 35 KDa antigens were detected; antibodies against the 92 KDa, 80 KDa, 66 KDa, 45 KDa, 31 KDa and 28 KDa antigens appeared later. All positive sera in the ELISA test were also positive in WB. Two antigen bands, 92 KDa and 35 KDa, were identified since the beginning and throughout the course of infection. These antigens merit further evaluation as candidates for use in diagnosis.
DEFF Research Database (Denmark)
Jakobsen, M. A.; Sprogoe, U.
2015-01-01
designed a genomic assay based on sequencing targeting the SNPs underlying the antigens of the Knops system. Study Design/Methods: Samples from a total of 105 blood donors and 2 patients were examined for polymorphisms in CR1 exon 29 by using PCR and subsequent Sanger sequencing. Results......Background/Case Studies: The antigens of the Knops (Kn) blood group system are associated with SNPs located on exon 29 and (to lesser extent) on exon 26 of the complement receptor 1 (CR1) gene. Because of a lack of proper typing antibodies, serologic detection of Kn antigens is not feasible. We....../Findings: With regard to Kn a and b antigens, we found SNP frequencies to be 90.5% for G/G (4681)* associated with Kn(a+b-) and 9.5% for G/A associated with Kn(a+b+). None of the 107 patients/donors were found to be homozygous for A/A associated with Kn(ab+). The frequencies of SNPs associated with the KCAM antigen...
Radioimmunoassay for tumor antigen of human cervical squamous cell carcinoma
International Nuclear Information System (INIS)
Kato, H.; Torigoe, T.
1977-01-01
A heterologous antiserum for human cervical squamous cell carcinoma was prepared and specificity determined by Ouchterlony immunodiffusion and immunofluorescence studies. With this antiserum, a tumor antigen was purified from human cervical squamous cell carcinoma tissue. The specificities of the antigen and the antiserum were then re-examined by a radioimmunoassay method using 125 I-labeled purified antigen. Although normal cervical tissue extract showed a moderate cross-reactivity in the radioimmunoassay, the circulating antigen activity could not be detected in normal women or in several patients with other carcinomas, whereas 27 of 35 patients with cervical squamous cell carcinoma showed detectable serum antigen activity. All patients with advanced stages of cervical squamous cell carcinoma showed detectable antigen levels. These results indicate that there is a quantitative abnormality, at least, of this tumor antigen in patients with cervical squamous cell carcinoma and that the radioimmunoassay for the antigen is a potentially useful tool in clinical care
Attallah, Abdelfattah M.; Bughdadi, Faisal A.; El-Shazly, Atef M.
2013-01-01
Currently, the laboratory diagnosis of human fascioliasis is based on the parasitological examination of parasite eggs in stool specimens and serological detection of specific antibodies in serum samples, which are often unreliable diagnostic approaches. Ideally, a sensitive and specific diagnostic test for Fasciola infection should be based on the detection of circulating Fasciola antigen, which implies active infection. Here, a 27-kDa-molecular-mass antigen was identified in a Fasciola gigantica adult worm antigen preparation, excretory-secretory products, and sera from F. gigantica-infected individuals, and it was not detected in antigenic extracts of other parasites and sera from noninfected individuals. The target antigen was isolated and partially characterized as a protein. Immunoperoxidase staining located the target epitope within teguments and guts of F. gigantica adult worms. The performance characteristics of a newly developed enzyme-linked immunosorbent assay (ELISA) based on F. gigantica circulating antigen detection in serum (FgCA-27 ELISA) were investigated using sera of 120 parasitologically diagnosed F. gigantica-infected individuals and 80 noninfected individuals. The area under the receiving operating characteristic (ROC) curve (AUC) for ELISA was significantly high (AUC = 0.961, P 93%), and a significant correlation (r = 0.715, P fascioliasis. PMID:23945158
DEFF Research Database (Denmark)
Tuxen, Malgorzata K.; Sölétormos, G; Petersen, P H
2001-01-01
The main objective with cancer antigen 125 (CA 125), carcinoembryonic antigen (CEA), and tissue polypeptide antigen (TPA) monitoring of ovarian cancer patients is to detect an early change of disease activity with high reliability. We hypothesized that a monitoring scheme for ovarian cancer patie...
Advantages and disadvantages of current diagnostic tests for the detection of Helicobacter pylori.
Mégraud, F
1996-01-01
Current tests used to detect Helicobacter pylori are either invasive (histological detection, culture, the polymerase chain reaction (PCR), smear examination) or non-invasive (serology, 13C-urea breath test). These tests vary in their sensitivity and specificity, and the choice of test will depend on the situation, for example, whether the test is to detect infection or the success of eradication treatment. The accuracy of histological tests depends, to a large degree, on the expertise of the pathologist, while the accuracy of culture can depend on the conditions in which the specimen is transported and processed. When performed under optimal conditions, both techniques give very good results. The PCR test has similar sensitivity and specificity to histological and culture tests but a strict protocol must be followed to avoid contamination with H. pylori DNA. The rapid urease test (with a reading taken 1 hour later) is suitable for diagnosis before treatment but its sensitivity decreases after treatment. Smear examination has limited sensitivity. The urea breath test and serology (specific IgG detected by enzyme-linked immunosorbent assay with purified antigens) have sensitivities close to those using the best of the biopsy methods. Other points to consider when selecting a test are its availability, the rapidity of the results (which can range from a few minutes to 2 weeks), possibilities for retrospective analysis, quantification and the detection of pathogenic properties, the globality of certain tests that present an overall picture of the stomach, thus avoiding errors in sampling, and the cost of the test. Important added value can be gained from certain tests: histology allows evaluation of the status of the mucosa, culture allows strain typing and tests for antibiotic susceptibility, and the breath test can confirm successful eradication without endoscopy. When the diagnostic tests are performed correctly, most of them are highly accurate.
ELISA with double antigen sandwich for screening specific serum anti-TP antibody in blood donors
International Nuclear Information System (INIS)
Wang Yiqing; Shi Zhixu
2002-01-01
Objective: To select a sensitive and specific laboratory examination suitable for screening serum anti-TP antibody in blood donors. Methods: The serum anti-TP antibody in 11271 blood donors were detected using ELISA with double antigen sandwich and the outcomes were compared with those using RPR assay. The conflicting specimen were confirmed by repeating the test with TPHA assay. Results: The positive rates of serum anti-TP antibody by ELISA with double antigen sandwich and RPR was 0.36% (41/11271) and 0.26% (29/11271), respectively. The coincidence of the detecting outcomes by ELISA with double antigen sandwich and RPR with TPHA was 97.5% (40/41) and 63.41%(26/41) respectively. Conclusion: Compared with RPR assay, ELISA with double antigen sandwich has higher sensibility and specificity for screening serum anti-TP antibody in blood donors
Directory of Open Access Journals (Sweden)
Marco Machetti
2009-03-01
Full Text Available Invasive aspergillosis (IA and candidemia are an increasing cause of morbidity and mortality in immunocompromised patients, but diagnostic procedures are often hampered by critical patients conditions. In recent years, non-culture methods have reached a standardization level suitable to be marketed and widely employed. A method for a panfungal antigenic diagnosis, is the detection in serum of (1→3-ß-D-Glucan (BDG, a polisaccaridic component of fungal cell wall. Best results can be obtained in Aspergillus, Candida and Fusarium infections, while the test performs poorly with Cryptococcus and in zygomycosis. The use of this method are limited by the high costs and by the need of disposable materials certified as glucan-free, in order to avoid false positive results. Galactomannan (GM antigen detection is a method for non-invasive diagnosis of IA. The assay, in latex agglutination (LA and enzymeimmunoassay (EIA format, detect GM in serum, whose presence correlates with IA. Sensitivity and specificity strongly fluctuate (50-100% and 81-98% respectively depending on the time of sampling, the positivity cut-off employed, the concomitant administration of antifungal drugs and of some antibiotics. Nevertheless the method is a very useful and widely employed tool for the diagnosis of IA. For the diagnosis of candidemia, two Candida antigens may be detected in serum: the 56°C heat-labile antigen in LA format, and the mannan antigen, in LA and EIA format. Both the methods perform quite well, but sensitivities and specificities are not so good to allow a routinely and useful use in clinical practice.
Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A
2014-12-01
Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases
Positive hepatitis B surface antigen tests due to recent vaccination: a persistent problem
Directory of Open Access Journals (Sweden)
Rysgaard Carolyn D
2012-09-01
Full Text Available Abstract Background Hepatitis B virus (HBV is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients. However, the time course and duration of this effect is unclear. The objective of this retrospective study was to clarify the frequency and duration of transient HBsAg positivity following vaccination against HBV. Methods The electronic medical record at an academic tertiary care medical center was searched to identify all orders for HBsAg within a 17 month time period. Detailed chart review was performed to identify all patients who were administered HBV vaccine within 180 days prior to HBsAg testing and also to ascertain likely cause of weakly positive (grayzone results. Results During the 17 month study period, 11,719 HBsAg tests were ordered on 9,930 patients. There were 34 tests performed on 34 patients who received HBV vaccine 14 days or less prior to HBsAg testing. Of these 34 patients, 11 had grayzone results for HBsAg that could be attributed to recent vaccination. Ten of the 11 patients were renal dialysis patients who were receiving HBsAg testing as part of routine and ongoing monitoring. Beyond 14 days, there were no reactive or grayzone HBsAg tests that could be attributed to recent HBV vaccination. HBsAg results reached a peak COI two to three days following vaccination before decaying. Further analysis of all the grayzone results within the 17 month study period (43 results out of 11,719 tests revealed that only 4 of 43 were the result of true HBV infection as verified by confirmatory testing. Conclusions Our study confirms that transient HBsAg positivity can occur in patients following HBV vaccination. The results suggest this positivity is unlikely to persist beyond 14 days
Gold nanoparticle-based low limit of detection Love wave biosensor for carcinoembryonic antigens.
Li, Shuangming; Wan, Ying; Su, Yan; Fan, Chunhai; Bhethanabotla, Venkat R
2017-09-15
In this work, a Love wave biosensing platform is described for detecting cancer-related biomarker carcinoembryonic antigen (CEA). An ST 90°-X quartz Love wave device with a layer of SiO 2 waveguide was combined with gold nanoparticles (Au NPs) to amplify the mass loading effect of the acoustic wave sensor to achieve a limit of detection of 37pg/mL. The strategy involves modifying the Au NPs with anti-CEA antibody conjugates to form nanoprobes in a sandwich immunoassay. The unamplified detection limit of the Love wave biosensor is 9.4ng/mL. This 2-3 order of magnitude reduction in the limit of detection brings the SAW platform into the range useful for clinical diagnosis. Measurement electronics and microfluidics are easily constructed for acoustic wave biosensors, such as the Love wave device described here, allowing for robust platforms for point of care applications for cancer biomarkers in general. Copyright © 2017 Elsevier B.V. All rights reserved.
International Nuclear Information System (INIS)
Sachse, H.J.; Falkenberg, F.W.; Scherberich, J.E.; Stefanescu, T.; Fassbinder, W.; Mondorf, A.W.; Schoeppe, W.
1981-01-01
In order to isolate urinary kidney antigens, the gammaglobulin fraction of an antiserum against human kidney cortex plasma membranes was coupled to Sepharose 4B. By immunospecific affinity chromatography an antigen fraction was obtained from the urine of a patient suffering from severe kidney disease. After gel filtration, the main fraction, eluted with the exclusion volume of a Sephadex G-200 column and enriched 16000-fold, was labelled with 131 I and used in a radioimmunoassay system. Soluble kidney antigens, presumably of proximal tubular origin, could be detected and quantified by the assay system in urine samples of patients with various diseases. The samples did not need to be treated, either concentrated or dialyzed, before application. The results of the experiments show a correlation between antigen excretion and kidney damage. Rejection episodes in patients with kidney transplants could be recognized early by enhanced antigen excretion. Potentially nephrotoxic drugs caused antigen excretion as well. In normal, healthy subjects output of the antigen was very low. The assay system might be of value for monitoring renal diseases. (Auth.)
Detection of Avian Antigen-Specific T Cells Induced by Viral Vaccines
DEFF Research Database (Denmark)
Dalgaard, Tina Sørensen; Norup, Liselotte Rothmann; Juul-Madsen, Helle Risdahl
2016-01-01
Live attenuated viral vaccines are widely used in commercial poultry production, but the development of new effective inactivated/subunit vaccines is needed. Studies of avian antigen-specific T cells are primarily based on analyses ex vivo after activating the cells with recall antigen. There is ......Live attenuated viral vaccines are widely used in commercial poultry production, but the development of new effective inactivated/subunit vaccines is needed. Studies of avian antigen-specific T cells are primarily based on analyses ex vivo after activating the cells with recall antigen...
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah
2016-08-30
The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.
International Nuclear Information System (INIS)
Acevedo Castro, Boris Ernesto
2012-01-01
The prostate cancer in Cuba is a problem of health (2672 diagnosed cases and 2769 deaths in 2007). Various diagnostic methods have been implemented for the detection and management of this disease, emphasizing among them (PSA) prostate-specific antigen serological determination. At this work was generated and characterized a panel of 11 antibodies (AcMs) monoclonal IgG1 detected with high affinity described major epitopes of the PSA, both in solution and attached to the test plate. From the panel obtained AcMs was the standardization of an essay type ELISA for the detection of serum total PSA (associated and free) equimolar, based on antibody monoclonal CB-PSA.4 in the coating and the CB-PSA.9 coupled with biotin as liner, with a detection limit of 0.15 ng/mL. Similarly, standardized system for detection in serum free PSA, based on the AcMs CB-PSA.4 (coating) and CB-PSA.2 coupled with biotin (liner), with a detection limit of 0.5 ng/mL. Finally, with the purpose of using PSA as standard in trials type ELISA, developed a simple method of inmunopurificación based on the AcM, CB-PSA.2, which was obtained the PSA with a purity exceeding 90%. Immunoassay Centre on the basis of the AcMs panel and the results of this study, developed and recorded two diagnostic systems for the detection of PSA in human serum. (author)
Efficacy demonstration of tetanus vaccines by double antigen ELISA.
Rosskopf, U; Noeske, K; Werner, E
2005-09-01
This paper describes a double antigen ELISA (DAE) for rapid, specific and reliable assessment of the antitetanus immune status of horses and sheep. Compared with the indirect ELISA, the double antigen ELISA has the advantage of species-independent testing of sera. Thanks to its test design, it is more specific since the detected antibodies are forced to bind tetanus toxoid twice. In addition, it is very sensitive to tetanus antibodies, enabling the detection of low antibody titres, in range which is relevant for the assessment of the protective status (tetanus toxin neutralising antibodies). The detection limit of the DAE for tetanus antibodies is in the order of 10(-4) EU/ml. A comparison of in vitro results of individual sera with in vivo titres showed that horse sera with titres of 0.04 and 0.05 EU/ml in the DAE showed titres of > 0.05 IU and 0.034 IU/ml respectively during in vivo testing thus indicating good agreement. For tested sheep sera which were rated > 0.05 IU/ml in vivo, the corresponding titre in the DAE was 0.24 EU/ml. Clear tetanus antitoxin establishment of protective ELISA limits requires further comparative examination of sera with low titres (tetanus vaccines ad us. vet. As a consequence, the toxin neutralisation test (still being the standard method of choice for quantifying tetanus toxin neutralising antitoxin titres) could be replaced, since it requires too great a number of animals per test and involves considerable suffering for the animals. The test described here reduces the use of mice and guinea pigs within vaccine efficacy testing. In addition, it involves less exposure of the laboratory personnel to toxin.
DEFF Research Database (Denmark)
Mustafa, A S; Amoudy, H A; Wiker, H G
1998-01-01
GroES, rPstS, rGroEL and rDnaK) antigens of Mycobacterium tuberculosis. The responses of PBMC to these defined antigens were compared with the corresponding results obtained with complex antigens, such as whole-cell M. tuberculosis, M. tuberculosis culture filtrate (MT-CF) and cell wall antigens, as well...... as the vaccine strain, Mycobacterium bovis bacillus Calmette-Guerin (BCG). In addition, M. tuberculosis and MT-CF-induced T-cell lines were tested in the same assays against the panel of purified and complex antigens. The compiled data from PBMC and T-cell lines tested for antigen-induced proliferation and IFN...
International Nuclear Information System (INIS)
Khusmith, S.; Tharavanij, S.; Patarapotikul, J.; Kasemsuth, R.; Bunnag, D.
1986-01-01
A solid phase competitive binding radioimmunoassay (RIA) was developed for the detection of Plasmodium falciparum in infected blood. A suspension of NP40 treated red blood cells was mixed with labelled antimalarial IgG, incubated and then added to malarial antigen coated microtitre plate. Antimalarial IgGs were purified either from high titre sera from individuals living in a malaria endemic area in Thailand or from a locally produced monoclonal antibody (MAB) which showed a bright generalized immunofluorescent staining pattern against all blood stages of P. falciparum, including gametocytes. This MAB reacted with 27 of 31 P. falciparum isolates from Thailand. Using dilution of red blood cells from in vitro cultures of P. falciparum, the test was found to detect parasites at levels equivalent to 13 and 2.2 parasites/10 6 red blood cells with labelled polyclonal IgG (PIgG) and labelled monoclonal IgG (MIgG), respectively. No false positive results were obtained among samples from non-malarial subjects. Of the samples that gave negative results upon microscopic examination, 50 and 35% were still positive with RIA using MIgG and PIgG, respectively. There was a correlation between RIA and the number of parasites, especially when MIgG was used. The results indicate that the IgG fraction of sera from individuals with natural acquired immunity to malaria showed a lower degree of sensitivity in parasite detection than the IgG from monoclonal antibody. (author)
Delaney, Meghan; Harris, Samantha; Haile, Askale; Johnsen, Jill; Teramura, Gayle; Nelson, Karen
2015-10-01
There has yet to be a comprehensive analysis of blood group antigen prevalence in Asian Americans and Native Americans. There may be ethnic differences in blood group frequencies that would result in clinically important mismatches through transfusion. Blood donors who self-identified as Asian or Native American were tested using a single-nucleotide polymorphism (SNP) DNA array (HEA BeadChip kit, Bioarray Solutions Ltd) that predicts expression of 38 human erythrocyte antigens (HEAs) and by serology for ABO, D, C, M, N, Jk(a) , and Jk(b) . The prevalence of blood group antigens was compared to published European prevalence. Discrepancies between SNP-predicted and serology-detected antigens were tallied. A total of 9087 blood donors were tested from nine Asian and Native American heritages. The predicted prevalence of selected antigens in the RHCE, JK, FY, MNS, LU, CO, and DO blood group systems were variable between Asian populations, but overall not significantly different than Europeans. Compared to European frequencies, Kell blood group allele frequencies were significantly different in the Chinese, Native American, Hawaiian/Pacific Islander, South Asian, and Southeast Asian heritage blood donors; Diego antigens Di(a) and Di(b) were different in donors of Native American and South Asian ancestries (p Asian and Native Americans donors. Several ethnic groups exhibited differences in HEA frequencies compared to Europeans. Genotype-serotype discrepancies were detected in all systems studied. © 2015 AABB.
Hadaschik, Boris; Su, Yun; Huter, Eva; Ge, Yingzi; Hohenfellner, Markus; Beckhove, Philipp
2012-04-01
Immunotherapy is a promising approach in an effort to control castration resistant prostate cancer. We characterized tumor antigen reactive T cells in patients with prostate cancer and analyzed the suppression of antitumor responses by regulatory T cells. Peripheral blood samples were collected from 57 patients with histologically confirmed prostate cancer, 8 patients with benign prostatic hyperplasia and 16 healthy donors. Peripheral blood mononuclear cells were isolated and antigen specific interferon-γ secretion of isolated T cells was analyzed by enzyme-linked immunospot assay. T cells were functionally characterized and T-cell responses before and after regulatory T-cell depletion were compared. As test tumor antigens, a panel of 11 long synthetic peptides derived from a total of 8 tumor antigens was used, including prostate specific antigen and prostatic acid phosphatase. In patients with prostate cancer we noted a 74.5% effector T-cell response rate compared with only 25% in patients with benign prostatic hyperplasia and 31% in healthy donors. In most patients 2 or 3 tumor antigens were recognized. Comparing various disease stages there was a clear increase in the immune response against prostate specific antigens from intermediate to high risk tumors and castration resistant disease. Regulatory T-cell depletion led to a significant boost in effector T-cell responses against prostate specific antigen and prostatic acid phosphatase. Tumor specific effector T cells were detected in most patients with prostate cancer, especially those with castration resistant prostate cancer. Since effector T-cell responses against prostate specific antigens strongly increased after regulatory T-cell depletion, our results indicate that immunotherapy efficacy could be enhanced by decreasing regulatory T cells. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Directory of Open Access Journals (Sweden)
Laura Masami SUMITA
Full Text Available SUMMARY Zika virus (ZKV infection is a huge public health problem in Brazil because of the increased incidence of microcephaly in neonates from infected mothers. Detection of specific IgG antibodies in maternal serum samples constitutes an important approach for diagnosing ZKV infection and evaluating its relationship with neonatal microcephaly. However, as there is no serological test produced in Brazil to detect IgM and IgG antibodies against ZKV, we sought to examine specific IgG in serum samples from patients or suspected mothers to detect previous infection and to test for specificity with regard to flaviviral infections occurring in the same area. Brazilian Zika virus native antigens were obtained from infected Vero cell layers or free virions in the culture medium and then used in ELISA. We tested sera from eight ZKV RNA-diagnosed infected patients (ZKVR, seven neonates with microcephaly and their mothers after delivery (MM, 140 dengue virus IgM-positive (DM and IgG (DG-positive patients, and 100 yellow fever (YF-vaccinated patients. According to the ELISA, ZKVR samples were mostly positive (7/8, and all the MM serum samples were positive for ZKV IgG (7/7. In contrast, cross-reactions for dengue or yellow fever-vaccinated patients were observed, including DM (48/95, DG (10/45 or YF (3/100 serum samples; however, these cross-reactions exhibited low antigen avidity so that 6 M urea largely removed this cross-reactivity, with only a few cross-reacting samples remaining (8/140. ELISA based on extracted virions was much more specific, with all ZKVR (8/8 and MM sera being positive for ZKV IgG (7/7 and only borderline cross-reactivity found for DM (6/95, DG (3/45 or YF (4/100-vaccinated serum samples. This technique (ELISA can identify specific IgG in ZKV-infected patients and may be helpful in diagnosing congenital infetions after maternal RNA virus clearance or in epidemiological studies.
Abnormal expression of blood group-related antigens in uterine endometrial cancers.
Tsukazaki, K; Sakayori, M; Arai, H; Yamaoka, K; Kurihara, S; Nozawa, S
1991-08-01
The expression of A, B, and H group antigens, Lewis group antigens (Lewis(a), Lewis(b), Lewis(x), and Lewis(y)), and Lc4 and nLc4 antigens, the precursor antigens of both groups, was examined immunohistochemically with monoclonal antibodies in 9 normal endometria, 6 endometrial hyperplasias, and 31 endometrial cancers. 1) A, B and/or H antigens were detected in endometrial cancers at an incidence of 51.6%, while no distinct localization of these antigens was observed in normal endometria. H antigen, the precursor of A and B antigens, was particularly frequently detected in endometrial cancers. 2) An increased rate of expression of Lewis group antigens, particularly Lewis(b) antigen, was observed in endometrial cancers compared with its expression in normal endometria. 3) Lc4 and nLc4 antigens were detected in endometrial cancers at rates of 41.9% and 38.7%, respectively, these expressions being increased compared with those in normal endometria. 4) These results suggest that a highly abnormal expression of blood group-related antigens in endometrial cancers occurs not only at the level of A, B, and H antigens and Lewis group antigens, but also at the level of their precursor Lc4 and nLc4 antigens. 5) Lewis(a), Lewis(b), and Lc4 antigens, built on the type-1 chain, are more specific to endometrial cancers than their respective positional isomers, Lewis(x), Lewis(y), and nLc4 antigens, built on the type-2 chain.
Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Saito, Hidetsugu
2006-02-01
A highly sensitive second generation HCV core antigen assay has recently been developed. We compared viral disappearance and kinetics data between commercially available core antigen assays, Lumipulse Ortho HCV Ag, and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor Test, Version 2 to estimate the predictive benefit of sustained viral response (SVR) and non-SVR in 59 patients treated with interferon and ribavirin combination therapy. We found a good correlation between HCV core Ag and HCV RNA level regardless of genotype. Although the sensitivity of the core antigen assay was lower than PCR, the dynamic range was broader than that of the PCR assay, so that we did not need to dilute the samples in 59 patients. We detected serial decline of core Ag levels in 24 hrs, 7 days and 14 days after interferon combination therapy. The decline of core antigen levels was significant in SVR patients compared to non-SVR as well as in genotype 2a, 2b patients compared to 1b. Core antigen-negative on day 1 could predict all 10 SVR patients (PPV = 100%), whereas RNA-negative could predict 22 SVR out of 25 on day 14 (PPV = 88.0%). None of the patients who had detectable serum core antigen on day 14 became SVR(NPV = 100%), although NPV was 91.2% on RNA negativity. An easy, simple, low cost new HCV core antigen detecting system seems to be useful for assessing and monitoring IFN treatment for HCV.
Directory of Open Access Journals (Sweden)
Wang Jie
2011-05-01
Full Text Available Abstract Background Schistosomiasis remains a major public health concern that afflicts millions of people worldwide. Low levels of Schistosoma infection require more sensitive diagnostic methods. In this study, a time-resolved fluoroimmunoassay (TRFIA was developed for detecting the signal transduction protein 14-3-3, a circulating antigen of Schistosoma japonicum. Results The detection limit of 14-3-3-TRFIA was 0.78 ng/ml, with a linear measurement range from 0.78 to 800 ng/ml. The average intra-assay and inter-assay variability of this TRFIA was 8.9% and 12.2% respectively, and the mean recovery rate ranged from 92.1% to 115.5%. Within the first 21 days post-infection in rabbits, the positive rates of the 14-3-3-TRFIA were distinctly higher compared to ELISA. All these findings illustrate that 14-3-3-TRFIA has a higher detection efficacy and is a good early diagnostic method for active Schistosoma infection. Conclusions A sandwich TRFIA for detecting the circulating antigen 14-3-3 of S. japonicum has been developed, and has demonstrated to be a good potential diagnostic method for schistosomiasis.
Energy Technology Data Exchange (ETDEWEB)
Tsai, H. Y., E-mail: annetsai@csmu.edu.tw [Chung Shan Medical University, Department of Applied Chemistry (China); Chang, C. Y.; Li, Y. C.; Chu, W. C.; Viswanathan, K.; Bor Fuh, C., E-mail: cbfuh@ncnu.edu.tw [National Chi Nan University, Department of Applied Chemistry (China)
2011-06-15
We combined a sandwich immunoassay, anti-CEA/CEA/anti-CEA, with functional magnetic ({approx}80 nm) and fluorescent ({approx}180 nm) nanoparticles in magnetic separators to demonstrate a detection method for carcinoembryonic antigen (CEA). Determination of CEA in serum can be used in clinical diagnosis and monitoring of tumor-related diseases. The CEA concentrations in samples were deduced and determined based on the reference plot using the measured fluorescent intensity of sandwich nanoparticles from the sample. The linear range of CEA detection was from 18 ng/mL to 1.8 pg/mL. The detection limit of CEA was 1.8 pg/mL. In comparison with most other detection methods, this method had advantages of lower detection limit and wider linear range. The recovery was higher than 94%. The CEA concentrations of two serum samples were determined to be 9.0 and 55 ng/mL, which differed by 6.7% (9.6 ng/mL) and 9.1% (50 ng/mL) from the measurements of enzyme-linked immunosorbent assay (ELISA), respectively. The analysis time can be reduced to one third of ELISA. This method has good potential for other biomarker detections and biochemical applications.
Case of rhesus antigen weak D type 4.2. (DAR category detection
Directory of Open Access Journals (Sweden)
L. L. Golovkina
2015-01-01
Full Text Available Serological methods of Rhesus antigens identification in humans cannot identify D-antigen variants. In this article the serological characteristics of Rhesus antigen D weak type 4.2. (Category DAR are described.
Evaluation of Antigen-Conjugated Fluorescent Beads to Identify Antigen-Specific B Cells
Directory of Open Access Journals (Sweden)
Isabel Correa
2018-03-01
Full Text Available Selection of single antigen-specific B cells to identify their expressed antibodies is of considerable interest for evaluating human immune responses. Here, we present a method to identify single antibody-expressing cells using antigen-conjugated fluorescent beads. To establish this, we selected Folate Receptor alpha (FRα as a model antigen and a mouse B cell line, expressing both the soluble and the membrane-bound forms of a human/mouse chimeric antibody (MOv18 IgG1 specific for FRα, as test antibody-expressing cells. Beads were conjugated to FRα using streptavidin/avidin-biotin bridges and used to select single cells expressing the membrane-bound form of anti-FRα. Bead-bound cells were single cell-sorted and processed for single cell RNA retrotranscription and PCR to isolate antibody heavy and light chain variable regions. Variable regions were then cloned and expressed as human IgG1/k antibodies. Like the original clone, engineered antibodies from single cells recognized native FRα. To evaluate whether antigen-coated beads could identify specific antibody-expressing cells in mixed immune cell populations, human peripheral blood mononuclear cells (PBMCs were spiked with test antibody-expressing cells. Antigen-specific cells could comprise up to 75% of cells selected with antigen-conjugated beads when the frequency of the antigen-positive cells was 1:100 or higher. In PBMC pools, beads conjugated to recombinant antigens FRα and HER2 bound antigen-specific anti-FRα MOv18 and anti-HER2 Trastuzumab antibody-expressing cells, respectively. From melanoma patient-derived B cells selected with melanoma cell line-derived protein-coated fluorescent beads, we generated a monoclonal antibody that recognized melanoma antigen-coated beads. This approach may be further developed to facilitate analysis of B cells and their antibody profiles at the single cell level and to help unravel humoral immune repertoires.
Evaluation of Antigen-Conjugated Fluorescent Beads to Identify Antigen-Specific B Cells.
Correa, Isabel; Ilieva, Kristina M; Crescioli, Silvia; Lombardi, Sara; Figini, Mariangela; Cheung, Anthony; Spicer, James F; Tutt, Andrew N J; Nestle, Frank O; Karagiannis, Panagiotis; Lacy, Katie E; Karagiannis, Sophia N
2018-01-01
Selection of single antigen-specific B cells to identify their expressed antibodies is of considerable interest for evaluating human immune responses. Here, we present a method to identify single antibody-expressing cells using antigen-conjugated fluorescent beads. To establish this, we selected Folate Receptor alpha (FRα) as a model antigen and a mouse B cell line, expressing both the soluble and the membrane-bound forms of a human/mouse chimeric antibody (MOv18 IgG1) specific for FRα, as test antibody-expressing cells. Beads were conjugated to FRα using streptavidin/avidin-biotin bridges and used to select single cells expressing the membrane-bound form of anti-FRα. Bead-bound cells were single cell-sorted and processed for single cell RNA retrotranscription and PCR to isolate antibody heavy and light chain variable regions. Variable regions were then cloned and expressed as human IgG1/k antibodies. Like the original clone, engineered antibodies from single cells recognized native FRα. To evaluate whether antigen-coated beads could identify specific antibody-expressing cells in mixed immune cell populations, human peripheral blood mononuclear cells (PBMCs) were spiked with test antibody-expressing cells. Antigen-specific cells could comprise up to 75% of cells selected with antigen-conjugated beads when the frequency of the antigen-positive cells was 1:100 or higher. In PBMC pools, beads conjugated to recombinant antigens FRα and HER2 bound antigen-specific anti-FRα MOv18 and anti-HER2 Trastuzumab antibody-expressing cells, respectively. From melanoma patient-derived B cells selected with melanoma cell line-derived protein-coated fluorescent beads, we generated a monoclonal antibody that recognized melanoma antigen-coated beads. This approach may be further developed to facilitate analysis of B cells and their antibody profiles at the single cell level and to help unravel humoral immune repertoires.
Evaluation of Antigen-Conjugated Fluorescent Beads to Identify Antigen-Specific B Cells
Correa, Isabel; Ilieva, Kristina M.; Crescioli, Silvia; Lombardi, Sara; Figini, Mariangela; Cheung, Anthony; Spicer, James F.; Tutt, Andrew N. J.; Nestle, Frank O.; Karagiannis, Panagiotis; Lacy, Katie E.; Karagiannis, Sophia N.
2018-01-01
Selection of single antigen-specific B cells to identify their expressed antibodies is of considerable interest for evaluating human immune responses. Here, we present a method to identify single antibody-expressing cells using antigen-conjugated fluorescent beads. To establish this, we selected Folate Receptor alpha (FRα) as a model antigen and a mouse B cell line, expressing both the soluble and the membrane-bound forms of a human/mouse chimeric antibody (MOv18 IgG1) specific for FRα, as test antibody-expressing cells. Beads were conjugated to FRα using streptavidin/avidin-biotin bridges and used to select single cells expressing the membrane-bound form of anti-FRα. Bead-bound cells were single cell-sorted and processed for single cell RNA retrotranscription and PCR to isolate antibody heavy and light chain variable regions. Variable regions were then cloned and expressed as human IgG1/k antibodies. Like the original clone, engineered antibodies from single cells recognized native FRα. To evaluate whether antigen-coated beads could identify specific antibody-expressing cells in mixed immune cell populations, human peripheral blood mononuclear cells (PBMCs) were spiked with test antibody-expressing cells. Antigen-specific cells could comprise up to 75% of cells selected with antigen-conjugated beads when the frequency of the antigen-positive cells was 1:100 or higher. In PBMC pools, beads conjugated to recombinant antigens FRα and HER2 bound antigen-specific anti-FRα MOv18 and anti-HER2 Trastuzumab antibody-expressing cells, respectively. From melanoma patient-derived B cells selected with melanoma cell line-derived protein-coated fluorescent beads, we generated a monoclonal antibody that recognized melanoma antigen-coated beads. This approach may be further developed to facilitate analysis of B cells and their antibody profiles at the single cell level and to help unravel humoral immune repertoires. PMID:29628923
Expression and Antigenic Evaluation of VacA Antigenic Fragment of Helicobacter Pylori
Hasanzadeh, Leila; Ghaznavi-Rad, Ehsanollah; Soufian, Safieh; Farjadi, Vahideh; Abtahi, Hamid
2013-01-01
Objective(s) : Helicobacter pylori, a human specific gastric pathogen is a causative agent of chronic active gastritis. The vacuolating cytotoxin (VacA) is an effective virulence factor involved in gastric injury. The aim of this study was to construct a recombinant protein containing antigenic region of VacA gene and determine its antigenicity. Materials and Methods: The antigenic region of VacA gene was detected by bioinformatics methods. The polymerase chain reaction method was used to amplify a highly antigenic region of VacA gene from chromosomal DNA of H. pylori. The eluted product was cloned into the prokaryotic expression vector pET32a. The target protein was expressed in the Escherichia coli BL21 (DE3) pLysS. The bacteria including pET32a-VacA plasmids were induced by IPTG. The antigenicity was finally studied by western blotting using sera of 15 H. pylori infected patients after purification. Results: Enzyme digestion analysis, PCR and DNA sequencing results showed that the target gene was inserted correctly into the recombinant vector. The expressed protein was purified successfully via affinity chromatography. Data indicated that antigenic region of VacA protein from Helicobacter pylori was recognized by all 15 patient’s sera. Conclusion : Our data showed that antigenic region of VacA protein can be expressed by in E. co.li. This protein was recognized by sera patients suffering from H. pylori infection. the recombinant protein has similar epitopes and close antigenic properties to the natural form of this antigen. Recombinant antigenic region of VacA protein also seems to be a promising antigen for protective and serologic diagnosis . PMID:23997913
Expression and Antigenic Evaluation of VacA Antigenic Fragment of Helicobacter Pylori
Directory of Open Access Journals (Sweden)
Leila Hasanzadeh
2013-07-01
Full Text Available Objective(s: Helicobacter pylori, a human specific gastric pathogen is a causative agent of chronic active gastritis. The vacuolating cytotoxin (VacA is an effective virulence factor involved in gastric injury. The aim of this study was to construct a recombinant protein containing antigenic region of VacA gene and determine its antigenicity. Materials and Methods: The antigenic region of VacA gene was detected by bioinformatics methods. The polymerase chain reaction method was used to amplify a highly antigenic region of VacA gene from chromosomal DNA of H. pylori. The eluted product was cloned into the prokaryotic expression vector pET32a. The target protein was expressed in the Escherichia coli BL21 (DE3 pLysS. The bacteria including pET32a-VacA plasmids were induced by IPTG. The antigenicity was finally studied by western blotting using sera of 15 H. pylori infected patients after purification. Results: Enzyme digestion analysis, PCR and DNA sequencing results showed that the target gene was inserted correctly into the recombinant vector. The expressed protein was purified successfully via affinity chromatography. Data indicated that antigenic region of VacA protein from Helicobacter pylori was recognized by all 15 patient’s sera. Conclusion : Our data showed that antigenic region of VacA protein can be expressed by in E. co.li. This protein was recognized by sera patients suffering from H. pylori infection. the recombinant protein has similar epitopes and close antigenic properties to the natural form of this antigen. Recombinant antigenic region of VacA protein also seems to be a promising antigen for protective and serologic diagnosis .
Directory of Open Access Journals (Sweden)
Supar
1996-03-01
Full Text Available Enterotoxigenic Escherichia coli (ETEC strains cause diarrhoeal disease in piglets and calves in Indonesia. These strains possess two virulence factors namely attachment and enterotoxin antigens . These factors could be detected phenotypically and genetically. Haemolytic Escherichia coli (E coli isolates possessing K88 fimbrial antigen associated with 0-group 108 and 149. They were positive for K88 gene and demonstrated their ability to produce heat labile enterotoxin (LT and genetically were all positive for LT gene . Seventeen isolates ofE coli K88 which associated with 0-group 149 were positive forSTb gene, other O-serotypes were negative . Ten isolates of Ecoli K88 which associated with 0-group 108 possessed K88, K99, LT and STa genes, but negative for STb gene . However, phenotypically the K99 antigen and STa toxin were not expressed under laboratory conditions, the reason was not well understood . E. coli K99 strains isolated from calves wit h diarrhoea were all associated with 0-group 9 and produced STa toxin when tested by suckling mousse bioassay. The E. coli K99 calf isolates were all hybridized with K99 and STa gene only . It is likely that K99 gene is associated with STa gene . The DNA hybridization technique is more convenience to be used for confirmation diagnosis of colibacillosis, however, not all veterinary laboratories could perform these tests .
G.F. Rimmelzwaan (Guus); N. Juntti; B. Klingeborn; J. Groen (Jan); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)
1990-01-01
textabstractAn enzyme-linked immunosorbent assay (ELISA) system was developed for the detection of canine parvovirus (CPV) or CPV antigen in dog faeces and two other ELISA systems were developed for the detection of CPV-specific antibodies in dog sera. The ELISA's were based on the use of
Directory of Open Access Journals (Sweden)
Emerence Crompot
Full Text Available Microparticles (MPs, also called microvesicles (MVs are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results.We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets. Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM and Scanning Electron microscopy (SEM.Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins.We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.
International Nuclear Information System (INIS)
Hamilton, R.G.; Alexander, E.; Adkinson, N.F.
1984-01-01
The performance of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) was examined for quantitation of filarial antigens (Brugia malayi and Dirofilaria immitis) in serum from infected human and animal hosts and non-infected controls. Multiple PEG concentrations were employed to determine the level of non-specific binding (NSB) in non-exposed human sera (NEHS) containing no filarial antigen. The NSB observed when 3 different 125 I-labelled IgG antibodies were added to 26 NEHS varied 3-fold and was correlated significantly with total serum IgM (r = 0.80, P 2 fragment of the 125 I-labelled antibody was used, but the correlation of NSB with total serum IgM remained significant (r = 0.57, P < 0.01). The presence of rheumatoid factor in NEHS sera also significantly increased NSB by an average of 3-fold. These effects eliminated the assay's ability to detect in sera from infected hosts filarial antigen the presence of which could be readily demonstrated by an immunoradiometric assay. The RIPEGA's precision (intra-assay coefficient of variation (CV) = 21% at 35% Bsub(max)) and reproducibility (inter-assay CV = 29% at 35% Bsub(max)) are less satisfactory than many alternative immunoassays. (Auth.)
Helicobacter pylori stool antigen test (HpSA) for the diagnosis of gastric infection
International Nuclear Information System (INIS)
Faruqui, A.N.; Majid, U.; Ahmed, L.; Khalil, M.; Hussan, M.U.
2007-01-01
To determine the accuracy of Helicobacter pylori Stool Antigen test (HpSA), compared with endoscopic histopathology for the diagnosis of gastric Helicobecter pylori infection. A total of 50 patients underwent endoscopy for gastric antral mucosal tissue biopsy for histopathology of H.pylori and advised for HpSA. Patient's information including age, gender, past history, presenting signs and symptoms, results of HpSA and histopathology were recorded. Sensitivity analysis was performed to calculate sensitivity, specificity, and predictive values of HpSA. Among 50 patients, 48% males and 52% females (M: F 1: 1.08), a total of 27 (54%) were true positive while 20 (40%) were true negative. Two patients were false negative and only one was false positive. Sensitivity of HpSA was, therefore, 93.1%, specificity 95% and positive and negative predictive values were 96.42% and 90.9% respectively. Helicobacter pylori stool antigen was an accurate and reliable test for the diagnosis of gastric H. pylori infection. (author)
Design and synthesis of multiple antigenic peptides and their application for dengue diagnosis.
Rai, Reeta; Dubey, Sameer; Santosh, K V; Biswas, Ashutosh; Mehrotra, Vinit; Rao, D N
2017-09-01
Major difficulty in development of dengue diagnostics is availability of suitable antigens. To overcome this, we made an attempt to develop a peptide based diagnosis which offers significant advantage over other methods. With the help of in silico methods, two epitopes were selected from envelope protein and three from NS1 protein of dengue virus. These were synthesized in combination as three multiple antigenic peptides (MAPs). We have tested 157 dengue positive sera confirmed for NS1 antigen. MAP1 showed 96.81% sera positive for IgM and 68.15% positive for IgG. MAP2 detected 94.90% IgM and 59.23% IgG positive sera. MAP3 also detected 96.17% IgM and 59.87% IgG positive sera. To the best of our knowledge this is the first study describing the use of synthetic multiple antigenic peptides for the diagnosis of dengue infection. This study describes MAPs as a promising tool for the use in serodiagnosis of dengue. Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Voevodin, A F; Lapin, B A; Agrba, V Z; Timanovskaya, V V
1978-01-01
A new technique (indirect double immunodiffusion) for detection of EBV-associated soluble antigen and corresponding antibodies has been developed. This technique includes three steps: 1) simple double immunodiffusion with extracts of Raji cells (or other EBV-genome positive cells) and human sera containing antibodies against EBV-associated soluble antigen; 2) extensive washing and treatment with anti-human globulin; 3) extensive washing and treatment with tannic acid. Using this test it was shown that the soluble antigen indistinguishable from EBV-associated soluble antigen was present in KMPG-1 cells producing HVP.
Carcinoembryonic antigen (CEA)
International Nuclear Information System (INIS)
Ephraim, K.H.; Cox, P.H.; Hamer, C.J.A. v.d.; Berends, W.; Delhez, H.
1977-01-01
The carcinoembryonic antigen (CEA) is a complex of antigen determinants and also the carrier of these determinants. Chemically it is a glycoprotein. Its occurrence in blood serum or urine is correlated with malignant disease. Several radioimmunoassays (RIA) have been developed, one by Hoffmann-Laroche and one by the Rotterdam Radiotherapeutic Institute. Both methods and the Hoffmann assay kit are tested. Specifications are given for isolation of the antigen, preparation of the antiserum, and the execution of the RIA. Biochemical and clinical aspects are discussed
van Doorn, O. J.; Bosman, D. K.; van't Hoff, B. W.; Taminiau, J. A.; ten Kate, F. J.; van der Ende, A.
2001-01-01
OBJECTIVE: To evaluate the Helicobacter pylori Stool Antigen (HpSA) test for the diagnosis of H. pylori infection in children. DESIGN AND SETTING: Prospective cohort study in an academic medical centre. PATIENTS AND METHODS: A total of 106 consecutive children who underwent gastroscopy were
International Nuclear Information System (INIS)
Dewair, M.
1989-01-01
Hypersensitivity pneumonitis (HP), an immunologically mediated chronic pulmonary disease, is the result of an inflammatory response of the lung initiated by the inhalation of environmental organic dusts. These organic dusts usually contain substances (antigens) capable of eliciting immune responses in humans. The symptoms of HP generally present as recurrent flu-like episodes which makes it difficult to establish the proper diagnosis. However, detection in patients' sera of high-titer antibodies against the environmental antigens could be of great help in identifying those materials causing the disease and which must be avoided. A highly specific and sensitive serodiagnostic test, a radioimmuno assay (RIA), was developed for measurement of antibodies against antigens relevant to Farmer's Lung Disease (FLD), a type of HP affecting farmers
Radioimmunoassay for hepatitis B core antigen
International Nuclear Information System (INIS)
Sagnelli, E.; Pereira, C.; Triolo, G.; Vernace, S.; Paronetto, F.
1982-01-01
Serum hepatitis B core antigen (HBcAg) is an important marker of hepatitis B virus replication. We describe an easy, sensitive radioimmunoassay for determination of HBcAg in detergent-treated serum pellets containing Dane particles. Components of a commercial kit for anticore determination are used, and HBcAG is measured by competitive inhibition of binding of 125 I-labeled antibodies to HBcAg with HBcAg-coated beads. We assayed for HBcAG in the sera of 49 patients with hepatitis B surface antigen (HBsAg)-positive chronic hepatitis, 50 patients with HBsAg-negative chronic hepatitis, and 30 healthy volunteers. HBcAg was detected in 41% of patients with HBsAg-positive chronic hepatitis but not in patients with HBsAg-negative chronic hepatitis. Hepatitis Be antigen (an antigen closely associated with the core of Dane particles) determined in the same sera by radioimmunoassay, was not detected in 50% of HBcAg-positive sera
Shedding of leukemia-associated P24 antigen by lymphoblastoid cell lines.
Komada, Y; Ochiai, H; Shimizu, K; Azuma, E; Kamiya, H; Sakurai, M
1987-12-01
We report the development of a unique enzyme-linked immunosorbent assay (ELISA) which makes possible the detection of leukemia-associated P24 antigen, utilizing its ability to bind the Ricinus communis agglutinin (RCA1) and a monoclonal antibody, SJ-9A4 simultaneously. Using the RCA1/SJ-9A4-ELISA, P24 antigen, as few as 50 X 10(3) cells from a common acute lymphoblastic leukemia (C-ALL) cell line could be detected. The presence of D-galactose gave complete and specific inhibition of P24 antigen binding to RCA1. Matched concentrations of D-glucose and D-sucrose had no effect on binding. The release of the P24 antigen into the culture medium by a C-ALL cell line maintained at 37 degrees C could be detected; however, no P24 antigen was present in the culture medium when the cells were maintained at 4 degrees C. Sequential analysis of the culture medium for soluble P24 antigen revealed that release of the P24 antigen associated with cell growth. Molecular sieve chromatography of concentrated culture medium indicated that shed P24 antigen was eluted in the macromolecule fraction. P24 antigen was detected in the cerebrospinal fluid (CSF) of four patients with P24 positive ALL at the time of relapse of the central nervous system (CNS) and was undetectable while in complete remission. The CSF from three patients with P24 negative ALL and three patients with aseptic meningitis had no detectable activity.
The use of a synthetic antigen for the serological diagnosis of human trichinellosis
Directory of Open Access Journals (Sweden)
Bruschi F.
2001-06-01
Full Text Available Hosts infected with Trichinella produce antibodies specific for an epitope common to the TSL-1 family antigens. This epitope contained uncommon terminal 3, 6-dideoxy-D-arabinohexose (so called tyvelose residues. The disaccharide moiety was synthesized and an immunodiagnostic assay was developed, which was specific and sensitive in swine trichinellosis. We aimed to verify the specificity and sensitivity of this immunodiagnostic test in human trichinellosis. 15 sera from normal subjects, 12 from patients with other parasitic diseases and 50 from trichinellosis patients were tested. Indirect enzyme linked immunosorbent assay (ELISA for specific IgG and an amplified ELISA for specific IgE were performed using β-tyvelose-GalNAc-bovine serum albumin (BSA disaccharide conjugate or T. spiralis muscle larvae excretory/secretory (E/S products, as antigens. Neither control sera nor other parasitic infection sera resulted positive both for IgG and IgE when synthetic or E/S antigens were used. In trichinellosis patient sera, specific IgG were present in 100 % of cases, irrespective of the antigen used, but whereas specific IgE were detected in 78 % using E/S antigens, a 100% positivity rate was obtained, using the β-tyvelose- BSA conjugate.
Review of Mycobacteriumavium subsp. paratuberculosis antigen candidates with diagnostic potential
DEFF Research Database (Denmark)
Mikkelsen, Heidi; Aagaard, Claus; Nielsen, Søren Saxmose
2011-01-01
antigens, heat shock antigens and hypothetical antigens. Strategies for evaluation of novel antigen candidates are discussed critically. Relatively few of the described antigens were evaluated for their use in CMI based diagnostic assays and so far, no obvious candidate has been identified...... to development of antibodies and shedding of detectable amounts of MAP. At present, available diagnostic assays are limited by the lack of MAP specific antigens included in these assays resulting in poor specificity. The objective of this review is to provide a systematic overview of diagnostic MAP antigen...... faeces; however, these diagnostic tools are often not applicable until years after infection. Detection of MAP specific cell-mediated immune (CMI) responses can serve as an alternative and be implemented in a diagnostic tool. CMI responses can be measured at an early stage of infection, prior...
Detection of antibodies to the extractable nuclear antigens by enzyme linked immunosorbent assay
International Nuclear Information System (INIS)
Aziz, Khalil A.; Fzizal, Abul A.
2005-01-01
Anti-extractable nuclear antigen (ENA) antibodies are a group of autoantibodies that are directed against various components of the cell nucleus. Antibodies to these antigens are closely associated with connective tissue disease. Early diagnosis of these diseases can prove very difficult and therefore clinicians rely on the use of anti-ENA antibody testing for the exclusion. Old methods of testing are time consuming and require great skills. For these reasons clinical immunology laboratories are switching to testing for anti-ENA antibodies by enzyme linked immunosorbent assay (ELISA). The latter assays are more sensitive and require little skills. In the present study we have investigated a number of different ELISA preparations. The study was conducted at Birmingham Heartlands Hospital during the period 2003. We tested a number of ENA-positive and negative samples using 3 different commercial ELISA preparations and compared the results with traditional CCIE-assay. The present study revealed that some ELISA preparations can be more sensitive than CCIE method. Laboratories still using later method should switch to ELISA. However it is important that laboratories evaluate a long range of different ELISA preparations before selecting the most optimal one. In addition it is recommended that laboratories then audit results in order to determine true significance of such results. Finally until the true significance of ELISA generated results is known, positive ENA-results should be interpreted in conjunction with the clinical picture and this would require close liaison in between the clinical immunology laboratory and clinicians
He, Qigai; Velumani, Sumathy; Du, Qingyun; Lim, Chee Wee; Ng, Fook Kheong; Donis, Ruben; Kwang, Jimmy
2007-01-01
The unprecedented spread of highly pathogenic avian influenza virus subtype H5N1 in Asia and Europe is threatening animals and public health systems. Effective diagnosis and control management are needed to control the disease. To this end, we developed a panel of monoclonal antibodies (MAbs) against the H5N1 avian influenza virus (AIV) and implemented an antigen-capture enzyme-linked immunosorbent assay (AC-ELISA) to detect the H5 viral antigen. Mice immunized with denatured hemagglutinin (H...
Sakai, Naoki; Taguri, Masataka; Kobayashi, Kazuki; Noguchi, Sumio; Ikeda, Shigeru; Koh, Hideshige; Satomi, Yoshiaki; Furuhata, Akihiko
2015-08-01
To investigate whether prostate-specific antigen-based screening reduced the prostate cancer mortality rate in Yokosuka, Japan. We carried out a cohort study, in which we compared clinical outcomes between patients detected by prostate-specific antigen-based screening (S group n = 524) versus those detected by other means (NS group n = 1044). Clinical and pathological factors were evaluated using Cox regression analyses and the Kaplan-Meier method. A total of 1.5% (8/524) of patients in the S group and 6.7% (70/1044) of those in the NS group died from prostate cancer during follow up. A total of 8.0% (42/524) of patients in the S group and 11.4% (119/1044) in the NS group died from other causes. The 10-year cancer specific survival rates of the S and NS groups were 97% and 86%, respectively (P prostate-specific antigen 100 ng/mL or more was significantly lower in the S group than the NS group: 7.8% and 23.0%, respectively (P specific survival (hazard ratio 4.808, 95% confidence interval 1.044-22.14, P = 0.044). Prostate-specific antigen-based population screening in Yokosuka City might help to reduce the prostate cancer mortality rate. © 2015 The Japanese Urological Association.
Directory of Open Access Journals (Sweden)
Seyyed Javad SEYYEDTABAEI
2017-06-01
Full Text Available Background: Visceral leishmaniasis (VL and cutaneous leishmaniasis (CL are important public health problems in Iran. We aimed to evaluate the diagnostic potential of Western blot (WB compared with indirect immunofluorescence test (IFAT to serodiagnosis of leishmaniasis.Methods: This study was performed from 2010-2014 and participants were different parts of Iran. Serum samples were obtained from 43 patients with proven CL, 33 patients with proven VL, 39 patients with other parasitic diseases and 23 healthy individuals. Results: WB sensitivity for CL and VL was 100% and 91%, compared to IFA 4.6% and 87.8%, respectively. Sera from patients with CL and VL recognized numerous antigens with molecular weights ranging from 14 to 68 kDa and 12 to 94 kDa, respectively. The most sensitive antigens were 14 and 16 kDa for CL recognized by 100% of the sera from patients with proven CL and 12, 14 and 16 kDa for VL, recognized by 63.6%, 100% and 63.6% of the sera from patients with proven VL respectively. WB analysis is more sensitive than IFAT for the diagnosis of leishmaniasis particularly in cases of cutaneous leishmaniasis. The 12, 14 and 16 kDa can be valuable diagnostic molecules for serodiagnosis of leishmaniasis because at least two immunogenic molecules were simultaneously detected by all patient sera, as well as produced antibodies against these antigens have no cross-reactivity with other control groups.Conclusion: WB could be useful for screening and serodiagnosis of CL and VL in epidemiologic studies in endemic areas.
Lim, Chun Shen; Goh, Siang Ling; Kariapper, Leena; Krishnan, Gopala; Lim, Yat-Yuen; Ng, Ching Ching
2015-08-25
Development of indirect enzyme-linked immunosorbent assays (ELISAs) often utilizes synthetic peptides or recombinant proteins from Escherichia coli as immobilized antigens. Because inclusion bodies (IBs) formed during recombinant protein expression in E. coli are commonly thought as misfolded aggregates, only refolded proteins from IBs are used to develop new or in-house diagnostic assays. However, the promising utilities of IBs as nanomaterials and immobilized enzymes as shown in recent studies have led us to explore the potential use of IBs of recombinant Epstein-Barr virus viral capsid antigen p18 (VCA p18) as immobilized antigens in ELISAs for serologic detection of nasopharyngeal carcinoma (NPC). Thioredoxin fusion VCA p18 (VCA-Trx) and IBs of VCA p18 without fusion tags (VCA-IBs) were purified from E. coli. The diagnostic performances of IgG/VCA-IBs, IgG/VCA-Denat-IBs (using VCA-IBs coated in 8mol/l urea), IgG/VCA-Trx, and IgG/VCA-Peptide assays were compared by screening 100 NPC case-control pairs. The IgG/VCA-Denat-IBs assay showed the best area under the receiver operating characteristic curve (AUC: 0.802; p<0.05), while the AUCs for the IgG/VCA-IBs, IgG/VCA-Trx, and IgG/VCA-Peptide assays were comparable (AUC: 0.740, 0.727, and 0.741, respectively). We improved the diagnostic performance of the ELISA significantly using IBs of recombinant VCA p18. Copyright © 2015 Elsevier B.V. All rights reserved.
Deteksi Antigen pada Kriptokokosis
Directory of Open Access Journals (Sweden)
Robiatul Adawiyah
2014-12-01
, laboratory and radiologicalexaminations. Laboratory examinations performed by morphological identification, serology and PCR. Morphological examination with India ink is positive when the number of fungi is around 10 10 cells/ml. Cultur examination is performed in Sabouraud dextrose agar (SDA and niger sheed agar (NSA medium, fungi grows in 5-7 days. Antigen and antibody detection could be performed on body fluid and do not take a long time. Detection of Cr. neoformans antibody can not show positive result in acute infection, IgA still positive after 1-2 years of healing phase and IgG can be persistent. The immunocompromised person showed very complex result and inconsistent in determining the diagnosis. Polysaccharides are the most instrumental component in Cr. neoformans virulence. The component of Polysaccharide especially glucuronoxylomannan is the most important marker in thediagnosis of cryptococcosis. Antigen detection of Cr. neoformans can show positive result in acute/chronic infection, high sensitivity and specificity. Polysaccharides can be detected from 10 ng/ ml of body fluid, so in minimal level of antigen we still can diagnose cryptococcosis.Keywords: Cr. neoformans, glucuronoxylomannan, antigen
Laperche, Syria; Nubling, C. Micha; Stramer, Susan L.; Brojer, Ewa; Grabarczyk, Piotr; Yoshizawa, Hiroshi; Kalibatas, Vytenis; El Elkyabi, Magdy; Moftah, Faten; Girault, Annie; van Drimmelen, Harry; Busch, Michael P.; Lelie, Nico
2016-01-01
BACKGROUND Hepatitis C virus (HCV) antigen and antibody combination assays have been launched as a cost-effective alternative to nucleic acid testing (NAT) for reducing the antibody-negative window period (WP). Later, a HCV antigen chemiluminescence immunoassay (CLIA) became available. STUDY DESIGN AND METHODS A panel composed of 337 HCV NAT–yield samples that were characterized for viral load (VL) and genotype was used to compare the sensitivity of two combination enzyme-linked immunosorbent assays (Monolisa, Bio-Rad; and Murex, formerly Abbott) and a HCV antigen CLIA (Abbott). Analytic sensitivity was compared with HCV RNA detection using Ultrio (Grifols) by testing serial dilutions of 10 genotype (gt)1 to gt4 samples. RESULTS HCV antigen CLIA detected 92.4% of samples, whereas Monolisa and Murex detected 38.3 and 47.5%, respectively. In the HCV RNA VL range of 105 to 107 IU/mL, Monolisa and Murex detected 38% to 56% of gt1, 85% to 78% of gt2, and 21% to 37% of gt3. The overall geometric mean 50% limit of detection (range) of Ultrio on gt1 to gt4 dilution series was 3.5 (1.2–7.7) copies/mL, compared to 3.3 × 106 (4.4 × 105-2.7 × 107), 3.4 × 106 (2.2 × 105–4.2 × 107), and 2728 (415–7243) copies/mL for Monolisa, Murex, and HCV antigen CLIA, respectively. CONCLUSION Analytical sensitivity of NAT was on average 1 million- and 780-fold higher than combination assays and HCV antigen CLIA, respectively. Relative sensitivities of combination assays differed for genotypes with Murex being more sensitive for gt1 and gt3 and Monolisa more sensitive for gt2. Although being less sensitive than NAT, combination assays could be considered in resource-limited settings since they detect 38% to 47% of seronegative WP donations. PMID:26013970
Directory of Open Access Journals (Sweden)
Bipulendu Jena
Full Text Available Clinical trials targeting CD19 on B-cell malignancies are underway with encouraging anti-tumor responses. Most infuse T cells genetically modified to express a chimeric antigen receptor (CAR with specificity derived from the scFv region of a CD19-specific mouse monoclonal antibody (mAb, clone FMC63. We describe a novel anti-idiotype monoclonal antibody (mAb to detect CD19-specific CAR(+ T cells before and after their adoptive transfer. This mouse mAb was generated by immunizing with a cellular vaccine expressing the antigen-recognition domain of FMC63. The specificity of the mAb (clone no. 136.20.1 was confined to the scFv region of the CAR as validated by inhibiting CAR-dependent lysis of CD19(+ tumor targets. This clone can be used to detect CD19-specific CAR(+ T cells in peripheral blood mononuclear cells at a sensitivity of 1∶1,000. In clinical settings the mAb is used to inform on the immunophenotype and persistence of administered CD19-specific T cells. Thus, our CD19-specific CAR mAb (clone no. 136.20.1 will be useful to investigators implementing CD19-specific CAR(+ T cells to treat B-lineage malignancies. The methodology described to develop a CAR-specific anti-idiotypic mAb could be extended to other gene therapy trials targeting different tumor associated antigens in the context of CAR-based adoptive T-cell therapy.
Gorday, William; Sadrzadeh, Hossein; de Koning, Lawrence; Naugler, Christopher T
2015-12-01
1.) Identify whether prostate-specific antigen velocity improves the ability to predict prostate biopsy diagnosis. 2.) Test whether there is an increase in the predictive capability of models when Gleason 7 prostate cancers are separated into a 3+4 and a 4+3 group. Calgary Laboratory Services' Clinical Laboratory Information System was searched for prostate biopsies reported between January 1, 2009 and December 31, 2013. Total prostate-specific antigen tests were recorded for each patient from January 1, 2007 to the most recent test before their recorded prostate biopsy. The data set was divided into the following three groups for comparison; benign, all prostate cancer and Gleason 7-10. The Gleason grade 7-10 group was further divided into 4+3 and 3+4 Gleason 7 prostate cancers. Prostate-specific antigen velocity was calculated using four different methods found in the literature. Receiver operator curves were used to assess operational characteristics of the tests. 4622 men between the ages of 40-89 with a prostate biopsy were included for analysis. Combining prostate-specific antigen velocity with total prostate-specific antigen (AUC=0.570-0.712) resulted in small non-statistically significant changes to the area under the curve compared to the area under the curve of total prostate-specific antigen alone (AUC=0.572-0.699). There were marked increases in the area under curves when 3+4 and 4+3 Gleason 7 cancers were separated. Prostate-specific antigen velocity does not add predictive value for prostate biopsy diagnosis. The clinical significance of the prostate specific antigen test can be improved by separating Gleason 7 prostate cancers into a 3+4 and 4+3 group. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
International Nuclear Information System (INIS)
Chaisingh, Arunee; Thammasart, Suree; Kamolsiripichaiporn, Somjai; Piadang Nattayana
2006-09-01
The result of the efficiencies of gamma irradiation at the dose of 10-60 kGy on highly pathogenic avian influenza virus, H5N1 (Thai isolate) revealed that gamma irradiation at the dose of 10 and 20 kGy could reduce the infectivity of Hanna but gamma irradiation at 30-60 kGy could inactivate H5N1 virus completely. All doses of gamma irradiation used in this experiment had no effect on antigenicity of hemagglutinin protein. Thus, gamma irradiation at the dose of 30- 60 kGy could be use safely for the antigen preparation to detect the antibody against H5N1 virus.
Autoantibodies and their antigens in autoimmune hepatitis.
Bogdanos, Dimitrios P; Mieli-Vergani, Giorgina; Vergani, Diego
2009-08-01
Autoantibody detection assists in the diagnosis and allows differentiation of autoimmune hepatitis (AIH) type 1 (AIH-1), characterized by antinuclear antibody (ANA) and/or smooth muscle antibody (SMA), and type 2 (AIH-2), distinguished by the presence of antibodies to liver-kidney microsome type 1 (anti-LKM1) and/or antibodies to liver cytosol type 1 (anti-LC1). Detection of atypical perinuclear antineutrophil cytoplasmic antibodies (pANCA) and anti-soluble liver antigen (SLA) antibodies can act as an additional pointer toward the diagnosis of AIH, particularly in the absence of the conventional autoantibodies. Routine autoantibody testing by indirect immunofluorescence has been recently complemented by molecular assays based on purified or recombinant antigens. Although the AIH-1-specific ANA and SMA targets need better definition, those of anti-LKM1 and anti-LC1 in AIH-2 have been clearly identified; the fine specificity of antibody reactivity and its clinical relevance to disease pathogenesis are the focus of ongoing investigation. This article critically discusses the current knowledge of the diagnostic and clinical significance of AIH-related autoantibody reactivities, focusing on key issues that the physician needs to be aware of to be able to request the appropriate testing and to interpret correctly the laboratory results within the clinical context of the patient. Copyright Thieme Medical Publishers.
Mustafaoglu, Nur; Alves, Nathan J; Bilgicer, Basar
2015-09-08
Oriented immobilization of antibodies and antibody fragments has become increasingly important as a result of the efforts to reduce the size of diagnostic and sensor devices to miniaturized dimensions for improved accessibility to the end-user. Reduced dimensions of sensor devices necessitate the immobilized antibodies to conserve their antigen binding activity for proper operation. Fab fragments are becoming more commonly used in small-scaled diagnostic devices due to their small size and ease of manufacture. In this study, we used the previously described UV-NBS(Biotin) method to functionalize Fab fragments with IBA-EG11-Biotin linker utilizing UV energy to initiate a photo-cross-linking reaction between the nucleotide binding site (NBS) on the Fab fragment and IBA-Biotin molecule. Our results demonstrate that immobilization of biotinylated Fab fragments via UV-NBS(Biotin) method generated the highest level of immobilized Fab on surfaces when compared to other typical immobilization methods while preserving antigen binding activity. UV-NBS(Biotin) method provided 432-fold, 114-fold, and 29-fold improved antigen detection sensitivity than physical adsorption, NHS-Biotin, and ε-NH3(+), methods, respectively. Additionally, the limit of detection (LOD) for PSA utilizing Fab fragments immobilized via UV-NBS(Biotin) method was significantly lower than that of the other immobilization methods, with an LOD of 0.4 pM PSA. In summary, site-specific biotinylation of Fab fragments without structural damage or loss in antigen binding activity provides a wide range of application potential for UV-NBS immobilization technique across numerous diagnostic devices and nanotechnologies.
Energy Technology Data Exchange (ETDEWEB)
Mohammed, M E. A. [University of Khartoum, Khartoum (Sudan)
2010-02-15
Breast cancer is associated with up regulation, down regulation of normal antigens or abnormal antigens. These antigens are very useful candidates as targets for the different breast cancer therapies and for vaccination trials. This study was done to characterize abnormal antigens, extract one of them and to produce monoclonal antibodies against the extracted antigen. One hundred and twenty Sudanese female patients were included in this study after informed consent. The mean age was 47. 2 years (16-80). Two tissue samples were obtained from each patient and they were confirmed as normal and cancerous breast tissues microscopically. 2D PAGE was used to analyze the protein content of samples. LC/MS and nr. fast a database search were used for separation and indentification of the abnormal proteins. Three different patterns of 2D Page results were obtained, the first pattern involved detection of four abnormal proteins in 26.7% of the patient cancerous tissues while they were undetected in the normal tissues of the same patients. In the second 2D PAGE result pattern the cancerous and the normal tissues of 67.5% patients were identical and they did not contain the four abnormal proteins while the third 2D PAGE pattern involved the presence of two abnormal antigens (from the four) in the cancerous tissues of 5.8% of the patients and they were absent from the normal tissues of the same patients. The four abnormal proteins were identified as, human Thioredoxin (D60nmutant), x-ray crystal structure of human galectin-1, retrocopy of tropomyosin 3(rc TPM3) and beta-tropomyosin (isoform 2). The primary and the secondary structures were obtained from the SWISSPROT and the PDB databases. Beta tropomyosin spot was extracted and used as antigen for monoclonal antibody production. Monoclonal antibody against beta- tropomyosin with a concentration of 0.35 mg/ml and a G11 anti beta-tropomyosin hybridoma cell line were produced. The monoclonal antibody was with single bad and
International Nuclear Information System (INIS)
Mohammed, M. E. A.
2010-02-01
Breast cancer is associated with up regulation, down regulation of normal antigens or abnormal antigens. These antigens are very useful candidates as targets for the different breast cancer therapies and for vaccination trials. This study was done to characterize abnormal antigens, extract one of them and to produce monoclonal antibodies against the extracted antigen. One hundred and twenty Sudanese female patients were included in this study after informed consent. The mean age was 47. 2 years (16-80). Two tissue samples were obtained from each patient and they were confirmed as normal and cancerous breast tissues microscopically. 2D PAGE was used to analyze the protein content of samples. LC/MS and nr. fast a database search were used for separation and indentification of the abnormal proteins. Three different patterns of 2D Page results were obtained, the first pattern involved detection of four abnormal proteins in 26.7% of the patient cancerous tissues while they were undetected in the normal tissues of the same patients. In the second 2D PAGE result pattern the cancerous and the normal tissues of 67.5% patients were identical and they did not contain the four abnormal proteins while the third 2D PAGE pattern involved the presence of two abnormal antigens (from the four) in the cancerous tissues of 5.8% of the patients and they were absent from the normal tissues of the same patients. The four abnormal proteins were identified as, human Thioredoxin (D60nmutant), x-ray crystal structure of human galectin-1, retrocopy of tropomyosin 3(rc TPM3) and beta-tropomyosin (isoform 2). The primary and the secondary structures were obtained from the SWISSPROT and the PDB databases. Beta tropomyosin spot was extracted and used as antigen for monoclonal antibody production. Monoclonal antibody against beta- tropomyosin with a concentration of 0.35 mg/ml and a G11 anti beta-tropomyosin hybridoma cell line were produced. The monoclonal antibody was with single bad and
Souriau, Armel; Freret, Sandrine; Foret, Benjamin; Willemsen, Peter T J; Bakker, Douwe; Guilloteau, Laurence A
2017-12-01
Currently Mycobacterium avium subsp. paratuberculosis (MAP) infection is diagnosed through indirect tests based on the immune response induced by the infection. The antigens commonly used in IFN-γ release assays (IGRA) are purified protein derivative tuberculins (PPD). However, PPDs, lack both specificity (Sp) and sensitivity (Se) in the early phase of infection. This study investigated the potential of 16 MAP recombinant proteins and five lipids to elicit the release of IFN-γ in goats from herds with or without a history of paratuberculosis. Ten recombinant proteins were selected as potential candidates for the detection of MAP infection in young goats. They were found to detect 25 to 75% of infected shedder (IS) and infected non-shedder (INS) kids younger than 10months of age. In comparison, PPD was shown to detect only 10% of INS and no IS kids. For seven antigens, Se (21-33%) and Sp (≥90%) of IGRA were shown to be comparable with PPD at 20months old. Only three antigens were suitable candidates to detect IS adult goats, although Se was lower than that obtained with PPD. In paratuberculosis-free herds, IGRA results were negative in 97% of indoor goats and 86% of outdoor goats using the 10 antigens. However, 22 to 44% of one-year-old outdoor goats were positive suggesting that they may be infected. In conclusion, this study showed that ten MAP recombinant proteins are potential candidates for early detection of MAP infected goats. Combining these antigens could form a possible set of MAP antigens to optimize the Se of caprine IGRA. Copyright © 2017 Elsevier Ltd. All rights reserved.
Alvarez, Rene; Njenga, M. Kariuki; Scott, Melissa; Seal, Bruce S.
2004-01-01
Avian metapneumoviruses (aMPV) cause an upper respiratory tract disease with low mortality but high morbidity, primarily in commercial turkeys, that can be exacerbated by secondary infections. There are three types of aMPV, of which type C is found only in the United States. The aMPV nucleoprotein (N) amino acid sequences of serotypes A, B, and C were aligned for comparative analysis. On the basis of the predicted antigenicity of consensus sequences, five aMPV-specific N peptides were synthesized for development of a peptide antigen enzyme-linked immunosorbent assay (aMPV N peptide-based ELISA) to detect aMPV-specific antibodies among turkeys. Sera from naturally and experimentally infected turkeys were used to demonstrate the presence of antibodies reactive to the chemically synthesized aMPV N peptides. Subsequently, aMPV N peptide 1, which had the sequence 10-DLSYKHAILKESQYTIKRDV-29, with variations at only three amino acids among aMPV serotypes, was evaluated as a universal aMPV ELISA antigen. Data obtained with the peptide-based ELISA correlated positively with total aMPV viral antigen-based ELISAs, and the peptide ELISA provided higher optical density readings. The results indicated that aMPV N peptide 1 can be used as a universal ELISA antigen to detect antibodies for all aMPV serotypes. PMID:15013970
Matsuda, Chikashi; Moriyama, Hidehiko; Taketani, Takeshi; Shibata, Hiroshi; Nagai, Atsushi
2011-01-01
The presence in serum of the Hepatitis B surface antigen (HBsAg), the outer envelope of the hepatitis B virus (HBV), indicates viral infection, used in laboratory tests to confirm this. We report a case of discrepancy among HBsAg test results detected between measurements in a subject with HB infection. Gene analysis demonstrated several S region gene mutations, not detected previously. We tested 12 measurements e.g., EIA, CLIA, CLEIA, F-EIA, MAT, and IC for whether they could detect our subject's HBsAg and found that it was not recognized by a method using only a single monoclonal antibody to detect HBsAg in two detection processes, in contrast to the 11 other measurements, which used two different antibodies. This case shows that amino acid substitution may cause a false negative result for HBsAg. Gene mutations known to occur in HBV, should thus trigger an awareness of the need to keep in mind that false negative results can happen in case such as ours.
Chlorphenesin: an antigen-associated immunosuppressant.
Whang, H Y; Neter, E
1970-07-01
Chlorphenesin (3-p-chlorophenoxy-1,2-propanediol), when injected intravenously together with either of two common bacterial antigens, inhibits the antibody response of the rabbit. The antigens studied are those common to Enterobacteriaceae and to gram-positive bacteria. The immunosuppression is contingent upon incubation of chlorphenesin and antigen in vitro prior to administration, since separate injection of antigen and inhibitor or of mixtures without prior incubation yields undiminished antibody response. Chlorphenesin, as shown by hemagglutination-inhibition tests, does not alter the antigenic determinants, because antibody neutralization occurs in the presence or absence of the drug. The immunosuppressive effect is reversible, since precipitation of chlorphenesin at 4 C substantially restores immunogenicity. Animals immunized with antigen-drug mixtures, which fail to respond with significant antibody production, nonetheless are immunologically primed. It is concluded that chlorphenesin represents another example of antigen-associated immunosuppressants.
Zhu, Hongying; Dale, Paul S.; Fan, Xudong
2009-05-01
Breast cancer is the most frequently diagnosed malignancy in women worldwide. Because of its great impact on society, a lot of research funding has been used to develop novel detection tools for aiding breast cancer diagnosis and prognosis. In this work, we demonstrated a simple, fast, and sensitive detection of circulating breast cancer biomarker CA15-3 with opto-fluidic ring resonator (OFRR) sensors. The OFRR sensor employs a thin-walled capillary with wall thickness less than 4 μm. The circular cross section of the capillary forms the optical ring resonator, in which the light circulates in the form of whispering gallery modes (WGMs). The capillary wall is thin enough that the evanescent field of the WGM extends into the capillary core and responds to refractive index changes in the capillary core or close to its interior surface. The WGM spectral position will change when the biomolecules bind to the surface, yielding quantitative and kinetic information about the biomolecule interaction. Here, the direct immunoassay method was employed for the detection of CA15-3 antigen without any signal amplification steps. The sensor performance in both PBS buffer and human serum were investigated, respectively. The experimental detection limit was 5 units/mL in PBS buffer and 30 units/mL for CA15-3 spiked in serum, both of which satisfied clinical diagnosis requirements. The potential use of the OFRR as the point-of-care device for breast cancer detection was tested by measuring the CA15-3 level in blood samples collected from stage IV breast cancer patients and the results were compared with standard clinical test.
Demonstration of tumor-associated antigens in dogs
International Nuclear Information System (INIS)
Warren, R.P.; Tsoi, M.S.; Henderson, B.H.; Weiden, P.L.; Storb, R.
1975-01-01
Procedures for the 51 Cr release assay using labeled L cells or lymphocytes and the indirect leukocyte migration test are described. These assays appear capable of detecting cellular immunity against tumor associated antigens in dogs. In 8 of 14 instances, lymphocyte-mediated cytotoxicity to autochthonous L cells was found as measured by 51 Cr release, and lymphocytes from 12 of 24 dogs produced the migration inhibition factor (MIF) when cultured with autochthonous tumor cells. Chromium-51 release occurred with 4 h of exposure of effector cells to target cells, suggesting that the immunity detected in the tumor dogs against their tumors is also present in vivo. With the leukocyte migration test, however, consistent MIF production was achieved only after 3 to 6 days in culture, suggesting that in vitro sensitization may result in increased MIF production
Peters, Philip J; Westheimer, Emily; Cohen, Stephanie; Hightow-Weidman, Lisa B; Moss, Nicholas; Tsoi, Benjamin; Hall, Laura; Fann, Charles; Daskalakis, Demetre C; Beagle, Steve; Patel, Pragna; Radix, Asa; Foust, Evelyn; Kohn, Robert P; Marmorino, Jenni; Pandori, Mark; Fu, Jie; Samandari, Taraz; Gay, Cynthia L
2016-02-16
Although acute HIV infection contributes disproportionately to onward HIV transmission, HIV testing has not routinely included screening for acute HIV infection. To evaluate the performance of an HIV antigen/antibody (Ag/Ab) combination assay to detect acute HIV infection compared with pooled HIV RNA testing. Multisite, prospective, within-individual comparison study conducted between September 2011 and October 2013 in 7 sexually transmitted infection clinics and 5 community-based programs in New York, California, and North Carolina. Participants were 12 years or older and seeking HIV testing, without known HIV infection. All participants with a negative rapid HIV test result were screened for acute HIV infection with an HIV Ag/Ab combination assay (index test) and pooled human immunodeficiency virus 1 (HIV-1) RNA testing. HIV RNA testing was the reference standard, with positive reference standard result defined as detectable HIV-1 RNA on an individual RNA test. Number and proportion with acute HIV infections detected. Among 86,836 participants with complete test results (median age, 29 years; 75.0% men; 51.8% men who have sex with men), established HIV infection was diagnosed in 1158 participants (1.33%) and acute HIV infection was diagnosed in 168 participants (0.19%). Acute HIV infection was detected in 134 participants with HIV Ag/Ab combination testing (0.15% [95% CI, 0.13%-0.18%]; sensitivity, 79.8% [95% CI, 72.9%-85.6%]; specificity, 99.9% [95% CI, 99.9%-99.9%]; positive predictive value, 59.0% [95% CI, 52.3%-65.5%]) and in 164 participants with pooled HIV RNA testing (0.19% [95% CI, 0.16%-0.22%]; sensitivity, 97.6% [95% CI, 94.0%-99.4%]; specificity, 100% [95% CI, 100%-100%]; positive predictive value, 96.5% [95% CI, 92.5%-98.7%]; sensitivity comparison, P testing detected 82% of acute HIV infections detectable by pooled HIV RNA testing. Compared with rapid HIV testing alone, HIV Ag/Ab combination testing increased the relative HIV diagnostic yield (both
Toward low-cost affinity reagents: lyophilized yeast-scFv probes specific for pathogen antigens.
Directory of Open Access Journals (Sweden)
Sean A Gray
Full Text Available The generation of affinity reagents, usually monoclonal antibodies, remains a critical bottleneck in biomedical research and diagnostic test development. Recombinant antibody-like proteins such as scFv have yet to replace traditional monoclonal antibodies in antigen detection applications, in large part because of poor performance of scFv in solution. To address this limitation, we have developed assays that use whole yeast cells expressing scFv on their surfaces (yeast-scFv in place of soluble purified scFv or traditional monoclonal antibodies. In this study, a nonimmune library of human scFv displayed on the surfaces of yeast cells was screened for clones that bind to recombinant cyst proteins of Entamoeba histolytica, an enteric pathogen of humans. Selected yeast-scFv clones were stabilized by lyophilization and used in detection assay formats in which the yeast-scFv served as solid support-bound monoclonal antibodies. Specific binding of antigen to the yeast-scFv was detected by staining with rabbit polyclonal antibodies. In flow cytometry-based assays, lyophilized yeast-scFv reagents retained full binding activity and specificity for their cognate antigens after 4 weeks of storage at room temperature in the absence of desiccants or stabilizers. Because flow cytometry is not available to all potential assay users, an immunofluorescence assay was also developed that detects antigen with similar sensitivity and specificity. Antigen-specific whole-cell yeast-scFv reagents can be selected from nonimmune libraries in 2-3 weeks, produced in vast quantities, and packaged in lyophilized form for extended shelf life. Lyophilized yeast-scFv show promise as low cost, renewable alternatives to monoclonal antibodies for diagnosis and research.
Antigenic characterisation of lyssaviruses in South Africa
Directory of Open Access Journals (Sweden)
Ernest Ngoepe
2014-09-01
Full Text Available There are at least six Lyssavirus species that have been isolated in Africa, which include classical rabies virus, Lagos bat virus, Mokola virus, Duvenhage virus, Shimoni bat virus and Ikoma lyssavirus. In this retrospective study, an analysis of the antigenic reactivity patterns of lyssaviruses in South Africa against a panel of 15 anti-nucleoprotein monoclonal antibodies was undertaken. A total of 624 brain specimens, collected between 2005 and 2009, confirmed as containing lyssavirus antigen by direct fluorescent antibody test, were subjected to antigenic differentiation. The lyssaviruses were differentiated into two species, namely rabies virus (99.5% and Mokola virus (0.5%. Furthermore, rabies virus was further delineated into two common rabies biotypes in South Africa: canid and mongoose. Initially, it was found that the canid rabies biotype had two reactivity patterns; differential staining was observed with just one monoclonal antibody. This difference was likely to have been an artefact related to sample quality, as passage in cell culture restored staining. Mongoose rabies viruses were more heterogeneous, with seven antigenic reactivity patterns detected. Although Mokola viruses were identified in this study, prevalence and reservoir host species are yet to be established. These data demonstrate the usefulness of monoclonal antibody typing panels in lyssavirus surveillance with reference to emergence of new species or spread of rabies biotypes to new geographic zones.
DEFF Research Database (Denmark)
Barington, T; Heilmann, C
1992-01-01
Recent advances in the development of conjugate polysaccharide vaccines for human use have stimulated interest in the use of assays detecting antibody-secreting cells (AbSC) with specificity for bacterial antigens. Here we present improved haemolytic plaque-forming cell (PFC) assays detecting Ab......SC with specificity for tetanus and diphtheria toxoid as well as for Haemophilus influenzae type b and pneumococcal capsular polysaccharides. These assays were found to be less time consuming, more economical and yielded 1.9-3.4-fold higher plaque numbers than traditional Jerne-type PFC assays. In the case of anti......-polysaccharide antibodies aggregation of secreted monomeric antibody (IgG) is critical for plaque formation and increases the avidity of binding to target cells....
Li, Shu-Xia; Yang, Yan-Qi; Jin, Li-Jian; Cai, Zhi-Gang; Sun, Zheng
2016-01-01
The aim of this study was to detect the survivin, carcinoembryonic antigen (CEA) and ErbB2 in the saliva, serum and local tumor-exfoliated cells of oral squamous cell carcinoma (OSCC) patients, for providing reliable tumor markers for the early detection of oral malignant cancer. The saliva, serum, and local tumor-exfoliated cell samples of 26 OSCC patients without chemotherapy and 10 non-cancer patients were collected in Department of Oral and Maxillofacial Surgery, School of Stomatology, Peking University. The contents of survivin, CEA and ErbB2 using were detected usingenzyme-linked immunosorbent assay. The survivin and CEA levels in saliva and local tumor-exfoliated cells of OSCC patients were significantly higher than those in the non-cancer patients (P oral malignant cancer.
Presentation of lipid antigens to T cells.
Mori, Lucia; De Libero, Gennaro
2008-04-15
T cells specific for lipid antigens participate in regulation of the immune response during infections, tumor immunosurveillance, allergy and autoimmune diseases. T cells recognize lipid antigens as complexes formed with CD1 antigen-presenting molecules, thus resembling recognition of MHC-peptide complexes. The biophysical properties of lipids impose unique mechanisms for their delivery, internalization into antigen-presenting cells, membrane trafficking, processing, and loading of CD1 molecules. Each of these steps is controlled at molecular and celular levels and determines lipid immunogenicity. Lipid antigens may derive from microbes and from the cellular metabolism, thus allowing the immune system to survey a large repertoire of immunogenic molecules. Recognition of lipid antigens facilitates the detection of infectious agents and the initiation of responses involved in immunoregulation and autoimmunity. This review focuses on the presentation mechanisms and specific recognition of self and bacterial lipid antigens and discusses the important open issues.
Turunen, H J
1983-01-01
A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of th...
Equine infectious anemia virus-infected dendritic cells retain antigen presentation capability
International Nuclear Information System (INIS)
Rivera, Julie A.; McGuire, Travis C.
2005-01-01
To determine if equine monocyte-derived dendritic cells (DC) were susceptible to equine infectious anemia virus (EIAV) infection, ex vivo-generated DC were infected with virus in vitro. EIAV antigen was detected by immunofluorescence 3 days post-infection with maximum antigen being detected on day 4, whereas there was no antigen detected in DC incubated with the same amount of heat-inactivated EIAV. No cytolytic activity was observed after EIAV WSU5 infection of DC. These monocyte-derived DC were more effective than macrophages and B cells in stimulating allogenic T lymphocytes. Both infected macrophages and DC stimulated similar levels of memory CTL responses in mixtures of CD8+ and CD4+ cells as detected with 51 Cr-release assays indicating that EIAV infection of DC did not alter antigen presentation. However, EIAV-infected DC were more effective than infected macrophages when used to stimulate memory CTL in isolated CD8+ cells. The maintenance of antigen processing and presenting function by EIAV-infected DC in vitro suggests that this function is maintained during in vivo infection
On the importance of controlling film architecture in detecting prostate specific antigen
Graça, Juliana Santos; Miyazaki, Celina Massumi; Shimizu, Flavio Makoto; Volpati, Diogo; Mejía-Salazar, J. R.; Oliveira, Osvaldo N., Jr.; Ferreira, Marystela
2018-03-01
Immunosensors made with nanostructured films are promising for detecting cancer biomarkers, even at early stages of the disease, but this requires control of film architecture to preserve the biological activity of immobilized antibodies. In this study, we used electrochemical impedance spectroscopy (EIS) to detect Prostate Specific Antigen (PSA) with immunosensors produced with layer-by-layer (LbL) films containing anti-PSA antibodies in two distinct film architectures. The antibodies were either adsorbed from solutions in which they were free, or from solutions where they were incorporated into liposomes of dipalmitoyl phosphatidyl glycerol (DPPG). Incorporation into DPPG liposomes was confirmed with surface plasmon resonance experiments, while the importance of electrostatic interactions on the electrical response was highlighted using the Finite Difference Time-Domain Method (FDTD). The sensitivity of both architectures was sufficient to detect the threshold value to diagnose prostate cancer (ca. 4 ng mL-1). In contrast to expectation, the sensor with the antibodies incorporated into DPPG liposomes had lower sensitivity, though the range of concentrations amenable to detection increased, according to the fitting of the EIS data using the Langmuir-Freundlich adsorption model. The performance of the two film architectures was compared qualitatively by plotting the data with a multidimensional projection technique, which constitutes a generic approach for optimizing immunosensors and other types of sensors.
ELISA testing for soy antigens in dry dog foods used in dietary elimination trials.
Willis-Mahn, Christine; Remillard, Rebecca; Tater, Kathy
2014-01-01
The use of elimination diet trials is necessary in the diagnosis of food allergies and intolerances. The objective of this study was to determine in vitro if four over-the-counter (OTC) dry dog foods carrying a "no soy" claim and seven veterinary therapeutic dry dog foods designed for food elimination trials were suitable for a soybean elimination trial. A 100 g sample of each diet plus one soy positive and one soy negative control diet were submitted for enzyme-linked immunosorbent assay testing to an independent food laboratory. The positive control diet contained >25 ppm soy protein antigens and the negative control contained 25 ppm. Three veterinary therapeutic diets had less than the lowest detectable limit of soy protein and four were positive (>2.5 ppm). OTC dog food diets that claim to contain "no soy" may contain high concentrations of soy protein and, therefore, should not be used in soy elimination trials in suspect food allergic dogs. The veterinary therapeutic diet selected for a soy elimination trial needs to be carefully chosen based on diet history.
Dobbelaere, D A; Prospero, T D; Roditi, I J; Kelke, C; Baumann, I; Eichhorn, M; Williams, R O; Ahmed, J S; Baldwin, C L; Clevers, H
1990-01-01
The Tac antigen component of the bovine interleukin-2 receptor was expressed as a Cro-beta-galactosidase fusion protein in Escherichia coli and used to raise antibodies in rabbits. These antibodies were used for flow cytofluorimetric analysis to investigate the expression of Tac antigen in a variety of Theileria parva-infected cell lines and also in three Theileria annulata-infected cell lines. Cells expressing Tac antigen on their surface were found in all T. parva-infected cell lines tested whether these were of T- or B-cell origin. T cells expressing Tac antigen could be CD4- CD8-, CD4+ CD8-, CD4- CD8+, or CD4+ CD8+. Tac antigen expression was observed both in cultures which had been maintained in the laboratory for several years and in transformed cell lines which had recently been established by infection of lymphocytes in vitro with T. parva. Northern (RNA) blot analysis demonstrated Tac antigen transcripts in RNA isolated from all T. parva-infected cell lines. Three T. annulata-infected cell lines which were not of T-cell origin were also tested. Two of them expressed Tac antigen on their surface. Abundant Tac antigen mRNA was detected in these T. annulata-infected cell lines, but only trace amounts were demonstrated in the third cell line, which contained very few Tac antigen-expressing cells. In all cell lines tested, whether cloned or uncloned, a proportion of the cells did not express detectable levels of Tac antigen on their surface. This was also the case for a number of other leukocyte surface markers. In addition, we showed that the interleukin-2 receptors were biologically functional, because addition of recombinant interleukin-2 to cultures stimulated cell proliferation. Recombinant interleukin-2 treatment also resulted in increased amounts of steady-state Tac antigen mRNA. The relevance of interleukin-2 receptor expression on Theileria-infected cells is discussed. Images PMID:1979317
LENUS (Irish Health Repository)
Hooton, Carmel
2012-02-03
BACKGROUND: The urea breath test (UBT) is the gold-standard non-invasive test for the detection of Helicobacter pylori infection, however, the lack of availability of the UBT due to the high cost of the test, and in particular the need for expensive analytical instrumentation, limits the usefulness of this method. Stool antigen assays may offer an alternative non-invasive method for the diagnosis of infection. OBJECTIVE: To compare the accuracy of three stool antigen assays (HpSA, IDEIA HpStAR, and ImmunoCard STAT) against the UBT for the primary diagnosis of H. pylori infection and for monitoring treatment outcome. METHODS: A total of 102 patients attending two gastroenterology day-case clinics for the investigation of dyspepsia were included. Each patient provided breath and stool samples for analysis. Patients who tested positive for H. pylori by the validated UBT were prescribed triple therapy and invited to return for repeat breath and stool sample analysis 6 weeks post-treatment. RESULTS: Of the 102 patients tested, 48 were diagnosed with H. pylori infection by the UBT. The HpSA assay interpreted 38 of these as positive (79% sensitive). Of the 54 UBT-negative patients the HpSA assay interpreted all 54 as negative (100% specific). The IDEIA HpStAR assay correctly identified 44 patients as positive (92% sensitive) and 50 as negative (92.5% specific). The ImmunoCard STAT assay interpreted 38 patients as positive (79% sensitive) and 52 as negative (96.3% specific). CONCLUSION: The findings indicate that the IDEIA HpStAR stool antigen kit is the most accurate assay of the three assays evaluated, and possibly represents a viable alternative to the UBT for the primary diagnosis of H. pylori infection and for monitoring treatment outcome.
Energy Technology Data Exchange (ETDEWEB)
Adler-Storthz, K.; Matson, D.O.; Adam, E.; Dreesman, G.R. (Baylor Univ., Houston, TX (USA). Coll. of Medicine)
1983-02-01
The specificity and sensitivity of a micro solid-phase radioimmunoassay (micro-SPRIA) that detects type-specific IgG antibody to herpes simplex virus types 1 and 2 (HSV1 and HSV2) were evaluated. Glycoproteins VP123 (molecular weight, 123,000) of HSV1 and VP119 (molecular weight, 119,000) of HSV2 were found to display the greatest degree of antigenic type-specificity of several HSV antigens tested with the micro-SPRIA technique. When testing a group of sera, negative for anti-HSV antibodies by microneutralization, in the micro-SPRIA, a range of negative reactivities was noted, suggesting that cut-points should be determined for each antigen preparation. The micro-SPRIA detected appropriate antibody activity in patients with recurrent infection and a marked agreement was noted in comparison to detection of anti-HSV antibodies measured with the microneutralization test. The type-specificity of the micro-SPRIA was substantiated by the independence of test results using VP119 and VP123 antigens for a random group of positive sera. The assay is rapid, specific, and sensitive and allows the testing of multiple serum samples with a standardized set of reagents.
IMMUNITY STATE IN THE OFFSPRING OF RATS EXPOSED ANTIGENS TOXOPLASMA GONDII
Directory of Open Access Journals (Sweden)
T. F. Sokolova
2014-01-01
Full Text Available Today the questions about possibility of development disturbances in the immune system of the fetus and the newborn in chronic toxoplasmosis are poorly understood. Aim of research: to detect immunological disturbances in the offspring of rats which have been administered antigens T. gondii.Two series of experiments was performed. In these experiments white female Wistar rats in the III trimester of pregnancy have been administered corpuscular antigen T. gondii. The 60 days-old offspring of these rats have been included in study group of 137 animals. CD3+ cells count was performed in peripherical blood and standard suspension of splenocytesrats offspring. Peripherical blood cells count was performed in the blood of the rats offspring. In the second experiment rats offspring have been administered sheep erythrocytes in 5 days, before euthanasia. In spleen of this rats antigen-produced cells was counted.In control group was included 118 animals, which was born from white female Wistar rats have been administered 0,9% NaCl solution. CD3+ cells was detected in Cytomics FC500 flow cytometry analyzer (Beckman Coulter,USA by use rats origne-specifed monoclonal antibodies Anti-Rat CD3-FITC (Beckman Coulter,USA. Hematological parameters was assessed by use hematological analyzer Excell-22 (USA.We observed, that CD3+ lymphocytes and antigen-produced cells was decreased in test group (degress of decrease CD3+ cells was 17,2%; р = 0,003 in spleen vs. control group, degress of decrease antigen-produced cells was 27,3%; р = 0,03 vs. control group. Number of leukocytes was increased in in test group (34,5%; р = 0,009 vs. control group. Power and strength correlation pleiades between studied blood and spenal markers were higher in in test group vs. control group (∑Gi = 16; ∑Di = 4,38 vs. ∑Gi = 13; ∑Di = 2,28. This phenomenon is probably due to the development adaptive reactions disruption in the immune system and development
Dykman, Lev A; Staroverov, Sergei A; Guliy, Olga I; Ignatov, Oleg V; Fomin, Alexander S; Vidyasheva, Irina V; Karavaeva, Olga A; Bunin, Viktor D; Burygin, Gennady L
2012-01-01
This article reports the first preparation of miniantibodies to Azospirillum brasilense Sp245 surface antigens by using a combinatorial phage library of sheep antibodies. The prepared phage antibodies were used for the first time for lipopolysaccharide and flagellin detection by dot assay, electro-optical analysis of cell suspensions, and transmission electron microscopy. Interaction of A. brasilense Sp245 with antilipopolysaccharide and antiflagellin phage-displayed miniantibodies caused the magnitude of the electro-optical signal to change considerably. The electro-optical results were in good agreement with the electron microscopic data. This is the first reported possibility of employing phage-displayed miniantibodies in bacterial detection aided by electro-optical analysis of cell suspensions.
Ohno, S; Luka, J; Falk, L; Klein, G
1977-12-15
In agreement with the findings of previous authors, we could not detect a virally determined nuclear antigen in Herpesvirus papio (HVP)-transformed baboon lymphoid lines by anticomplementary staining in situ, as for EBNA. However, by means of our recently developed acid-fixed nuclear binding technique an EBNA-like antigen could be readily demonstrated, after extraction from both producer and non-producer lines. We propose to designate the antigen as HUPNA. It can be detected by a human anti-EBNA antibody, suggesting cross-reactivity, if not identity, between EBNA and HUPNA. HVP-DNA carrying non-producer lines, negative for in situ ACIF stainability but capable of yielding HUPNA by the nuclear binding technique, can be superinfected with EBV, with brilliant EBNA expression as the result, suggesting that the defective in situ staining is a property associated with the baboon HVP, rather than the baboon lymphoid cell per se.
Detection of a human intracisternal A-type retroviral particle antigenically related to HIV
Garry, R. F.; Fermin, C. D.; Hart, D. J.; Alexander, S. S.; Donehower, L. A.; Luo-Zhang, H.
1990-01-01
Sjogren's syndrome is an autoimmune disease that is characterized by dryness of the mouth and eyes. The loss of salivary and lacrimal gland function is accompanied by lymphocytic infiltration. Because similar symptoms and glandular pathology are observed in certain persons infected with human immunodeficiency virus (HIV), a search was initiated for a possible retroviral etiology in this syndrome. A human intracisternal A-type retroviral particle that is antigenically related to HIV was detected in lymphoblastoid cells exposed to homogenates of salivary tissue from patients with Sjogren's syndrome. Comparison of this retroviral particle to HIV indicates that they are distinguishable by several ultrastructural, physical, and enzymatic criteria.
Antigen based detection of cystic echinococcosis in buffaloes using ELISA and Dot-EIA.
Sangaran, A; Bino Sundar, S T; Latha, Bhaskaran Ravi
2017-03-01
Cystic echinococcosis is caused by the larval stage of the dog tapeworm, Echinococcus granulosus . The disease is recognized as one of the world's major zoonoses affecting human beings and domestic animals apart from its economic and public health importance. Development of the cysts in the intermediate host such as buffaloes occurs in the lungs, liver and other organs. In this study, detection of circulating antigen in the diagnosis of cystic echinococcosis in buffaloes was done using enzyme linked immunosorbent assay and Dot-Enzyme immunoassay (Dot-EIA). The sensitivity and specificity were determined as 89 and 92 % respectively, whereas those of Dot-EIA were determined as 94 and 96 %.
Rapid detection of EBOLA VP40 in microchip immunofiltration assay
Miethe, Peter; Gary, Dominik; Hlawatsch, Nadine; Gad, Anne-Marie
2015-05-01
In the spring of 2014, the Ebola virus (EBOV) strain Zaire caused a dramatic outbreak in several regions of West Africa. The RT-PCR and antigen capture diagnostic proved to be effective for detecting EBOV in blood and serum. In this paper, we present data of a rapid antigen capture test for the detection of VP40. The test was performed in a microfluidic chip for immunofiltration analysis. The chip integrates all necessary assay components. The analytical sensitivity of the rapid test was 8 ng/ml for recombinant VP40. In serum and whole blood samples spiked with virus culture material, the detection limit was 2.2 x 102 PFU/ml. The performance data of the rapid test (15 min) are comparable to that of the VP40 laboratory ELISA.
DEFF Research Database (Denmark)
Mustafa, A S; Amoudy, H A; Wiker, H G
1998-01-01
We have screened peripheral blood mononuclear cells (PBMC) from tuberculosis (TB) patients for proliferative reactivity and interferon-gamma (IFN-gamma) secretion against a panel of purified recombinant (r) and natural (n) culture filtrate (rESAT-6, nMPT59, nMPT64 and nMPB70) and somatic-derived (r......GroES, rPstS, rGroEL and rDnaK) antigens of Mycobacterium tuberculosis. The responses of PBMC to these defined antigens were compared with the corresponding results obtained with complex antigens, such as whole-cell M. tuberculosis, M. tuberculosis culture filtrate (MT-CF) and cell wall antigens, as well...... as the vaccine strain, Mycobacterium bovis bacillus Calmette-Guerin (BCG). In addition, M. tuberculosis and MT-CF-induced T-cell lines were tested in the same assays against the panel of purified and complex antigens. The compiled data from PBMC and T-cell lines tested for antigen-induced proliferation and IFN...
Mycoplasma fermentans glycolipid-antigen as a pathogen of rheumatoid arthritis
International Nuclear Information System (INIS)
Kawahito, Yutaka; Ichinose, Sizuko; Sano, Hajime; Tsubouchi, Yasunori; Kohno, Masataka; Yoshikawa, Toshikazu; Tokunaga, Daisaku; Hojo, Tatsuya; Harasawa, Ryo; Nakano, Teruaki; Matsuda, Kazuhiro
2008-01-01
Mycoplasma fermentans has been suspected as one of the causative pathogenic microorganisms of rheumatoid arthritis (RA) however, the pathogenic mechanism is still unclear. We, previously, reported that glycolipid-antigens (GGPL-I and III) are the major antigens of M. fermentans. Monoclonal antibody against the GGPL-III could detect the existence of the GGPL-III antigens in synovial tissues from RA patients. GGPL-III antigens were detected in 38.1% (32/84) of RA patient's tissues, but not in osteoarthritis (OA) and normal synovial tissues. Immunoelectron microscopy revealed that a part of GGPL-III antigens are located at endoplasmic reticulum. GGPL-III significantly induced TNF-α and IL-6 production from peripheral blood mononulear cells, and also proliferation of synovial fibroblasts. Further study is necessary to prove that M. fermentans is a causative microorganism of RA; however, the new mechanisms of disease pathogenesis provides hope for the development of effective and safe immunotherapeutic strategies based on the lipid-antigen, GGPL-III, in the near future
Directory of Open Access Journals (Sweden)
Kolibo D. V.
2009-06-01
Full Text Available Aim. To develop approach for detection of scFv and their complexes with antigens. Methods. The fusion proteins, which include sequences of scFv and staphylococcal protein A, were constructed and the obtained bifunctional molecules were immunochemically analysed. Results. It was shown, that scFv fused with protein A and their complexes with antigens are effectively recognized by labelled immunoglobulins with unrestricted antigenic specificity. Conclusions. The fusion of scFv with protein A fragment is a perspective approach to increase the efficiency of application in ELISA. The obtained scFv, fused with protein A, could be used for development of test-systems for the detection of diphtheria toxin.
Human antibody and antigen response to IncA antibody of Chlamydia trachomatis.
Tsai, P Y; Hsu, M C; Huang, C T; Li, S Y
2007-01-01
The high prevalence of C. trachomatis worldwide has underscored the importance of identifying specific immunogenic antigens in facilitating diagnosis as well as vaccine development. The aim of this study is to evaluate IncA antibody and antigen production in natural human infections. Our temporal expression study showed that IncA transcription and protein expression could be detected as early as 4 hours after the start of infection. Antibody responses could be detected in urine and genital swab samples from C. trachomatis-positive patients. It is especially interesting to note that the IncA antigen could be detected in urine. In conclusion, we have identified IncA as an important antigen in human. The potential applicability of the IncA antibody or antigen in the diagnosis as well as to vaccine development for C. trachomatis is also discussed.
Use of Recombinant Antigens for the Diagnosis of Invasive Candidiasis
Directory of Open Access Journals (Sweden)
Ana Laín
2008-01-01
Full Text Available Invasive candidiasis is a frequent and often fatal complication in immunocompromised and critically ill patients. Unfortunately, the diagnosis of invasive candidiasis remains difficult due to the lack of specific clinical symptoms and a definitive diagnostic method. The detection of antibodies against different Candida antigens may help in the diagnosis. However, the methods traditionally used for the detection of antibodies have been based on crude antigenic fungal extracts, which usually show low-reproducibility and cross-reactivity problems. The development of molecular biology techniques has allowed the production of recombinant antigens which may help to solve these problems. In this review we will discuss the usefulness of recombinant antigens in the diagnosis of invasive candidiasis.
Hoane, Jessica S; Morrow, Jennifer K; Saville, William J; Dubey, J P; Granstrom, David E; Howe, Daniel K
2005-09-01
Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM.
Oncogenic cancer/testis antigens
DEFF Research Database (Denmark)
Gjerstorff, Morten F; Andersen, Mads H; Ditzel, Henrik J
2015-01-01
Recent developments have set the stage for immunotherapy as a supplement to conventional cancer treatment. Consequently, a significant effort is required to further improve efficacy and specificity, particularly the identification of optimal therapeutic targets for clinical testing. Cancer....../testis antigens are immunogenic, highly cancer-specific, and frequently expressed in various types of cancer, which make them promising candidate targets for cancer immunotherapy, including cancer vaccination and adoptive T-cell transfer with chimeric T-cell receptors. Our current understanding of tumor...... immunology and immune escape suggests that targeting oncogenic antigens may be beneficial, meaning that identification of cancer/testis antigens with oncogenic properties is of high priority. Recent work from our lab and others provide evidence that many cancer/testis antigens, in fact, have oncogenic...
DEFF Research Database (Denmark)
Stensballe, L G; Trautner, S; Kofoed, P-E
2002-01-01
detection was defined as any test being positive. RESULTS: RSV antigen was detected in 84 (13%) children, the prevalence being 19% (41/219) among infants aged 230) in older children. Sensitivity of antigen detection was higher in NPA (92...
Khan, M A Hannan; Ullah, Rizwan; Rehman, Abdur; Rehman, Lubna; P A, Ahammed Shareef; Abidi, S M A
2017-01-01
The digenetic trematode Fasciola gigantica is a parasite of great agricultural and economic importance. Along with Fasciola hepatica, F. gigantica incurs huge economic losses to the agricultural sector. Because of unavailability of an effective and commercial vaccine, the earliest diagnosis of the disease is the only way to control the disease. The conventional coprological techniques are able to detect the disease only after the parasites get matured and starts releasing their eggs with the faeces of host, therefore prepatent infection remain undiagnosed. The alternative method is by serological tests that uses circulatory antigens. Despite high sensitivity, their reliability is quite low because of the common antigens shared between different helminth parasites. To overcome this, investigation was shifted to identify the copro-antigens which could be more sensitive and reliable. In the present study, we tried to identify some of the immunodominant proteins from the Excretory Secretory (ES) product of F. gigantica which can be further characterized and used for early detection of infection and also as drug and vaccine candidates. The ES products of F. gigantica were collected and used for raising the polyclonal antibody in rabbit. The polypeptide profile was generated as well as immunogenic polypeptides were identified. The Source of ES antigen was immunolocalized using confocal microscopy and dot blot assay was performed to diagnose field infection. The polypeptide profile of ES products revealed a total of 24 polypeptides out of which 12 immunogenic polypeptides were identified by western blotting. Confocal micrographs showed the immunolocalization of antigens in the intestinal caecae, vitalline glands, gonads as well as in the tegument of the worm. The dot blot assay confirmed the utility of ES products for the detection of field infection. Subsequently, cross reactivity was found negative with Gigantocotyle explanatum; an amphitome parasite of same habitat
Directory of Open Access Journals (Sweden)
M A Hannan Khan
Full Text Available The digenetic trematode Fasciola gigantica is a parasite of great agricultural and economic importance. Along with Fasciola hepatica, F. gigantica incurs huge economic losses to the agricultural sector. Because of unavailability of an effective and commercial vaccine, the earliest diagnosis of the disease is the only way to control the disease. The conventional coprological techniques are able to detect the disease only after the parasites get matured and starts releasing their eggs with the faeces of host, therefore prepatent infection remain undiagnosed. The alternative method is by serological tests that uses circulatory antigens. Despite high sensitivity, their reliability is quite low because of the common antigens shared between different helminth parasites. To overcome this, investigation was shifted to identify the copro-antigens which could be more sensitive and reliable. In the present study, we tried to identify some of the immunodominant proteins from the Excretory Secretory (ES product of F. gigantica which can be further characterized and used for early detection of infection and also as drug and vaccine candidates. The ES products of F. gigantica were collected and used for raising the polyclonal antibody in rabbit. The polypeptide profile was generated as well as immunogenic polypeptides were identified. The Source of ES antigen was immunolocalized using confocal microscopy and dot blot assay was performed to diagnose field infection. The polypeptide profile of ES products revealed a total of 24 polypeptides out of which 12 immunogenic polypeptides were identified by western blotting. Confocal micrographs showed the immunolocalization of antigens in the intestinal caecae, vitalline glands, gonads as well as in the tegument of the worm. The dot blot assay confirmed the utility of ES products for the detection of field infection. Subsequently, cross reactivity was found negative with Gigantocotyle explanatum; an amphitome parasite
Khan, Mohsin; Dhanwani, Rekha; Kumar, Jyoti S; Rao, P V Lakshmana; Parida, Manmohan
2014-07-01
Despite the fact that Chikungunya resurgence is associated with epidemic of unprecedented magnitude, there are challenges in the field of its clinical diagnosis. However, serological tests in an ELISA format provide a rapid tool for the diagnosis of Chikungunya infection. Indeed, ELISAs based on recombinant proteins hold a great promise as these methods are cost effective and are free from the risk of handling biohazardous material. In this study, the performance of recombinant CHIKV antigens was compared in various ELISA formats for the diagnosis of Chikungunya. Two recombinant antigens derived from the envelope proteins of Chikungunya virus were prepared and evaluated by comparing their competence for detecting circulating antibodies in serum samples of patients infected with CHIKV using MAC-ELISA and indirect IgM-ELISA. The efficacy of the recombinant antigens was also compared with the native antigen. The indirect antibody capture IgM microplate ELISA revealed ≥90% concordance with the native antigen in detecting the CHIKV specific IgM antibodies whereas the recombinant antigen based MAC-ELISA showed 100% specificity. The recombinant antigens used in this study were effective and reliable targets for the diagnosis of CHIKV infection and also provide an alternative for native antigen use which is potentially biohazardous. © 2013 Wiley Periodicals, Inc.
Directory of Open Access Journals (Sweden)
Shaswati Subhadarsini Pany
2016-03-01
Full Text Available Aim: The aim of the present study was to carry out antigenic detection of bluetongue virus (BTV among the small ruminant population of two different geographical regions of Odisha (coastal and central using recombinant VP7 (r-VP-7 based sandwich enzyme-linked immunosorbent assay (s-ELISA. Materials and Methods: Blood samples (n=274 were collected from two different geographical pockets of Odisha, which covered mostly the coastal and central regions. Of the total samples under study 185 were from goat and 89 were from sheep. The blood samples were tested for the presence of BTV antigen by r-VP7 based s-ELISA. Results: r-VP-7 s-ELISA detected BTV antigen in 52.43% and 44.94% of the goat and sheep population under study, respectively. This study highlights the antigenic persistence of BTV in the state for the 1st time. Conclusion: This high antigenic presence in both sheep and goat population suggests an alarming BTV infection in field conditions which warrants more systematic study directed toward isolation and characterization studies as well as the implementation of control strategy for BT in Odisha.
Patra, Kailash P.; Saito, Mayuko; Atluri, Vidya L.; Rolán, Hortensia G.; Young, Briana; Kerrinnes, Tobias; Smits, Henk; Ricaldi, Jessica N.; Gotuzzo, Eduardo; Gilman, Robert H.; Tsolis, Renee M.; Vinetz, Joseph M.
2014-01-01
Human brucellosis is most commonly diagnosed by serology based on agglutination of fixed Brucella abortus as antigen. Nucleic acid amplification techniques have not proven capable of reproducibly and sensitively demonstrating the presence of Brucella DNA in clinical specimens. We sought to optimize
International Nuclear Information System (INIS)
Wun, T.C.; Capuano, A.
1987-01-01
A two-site immunoradiometric assay for tissue plasminogen activator (tPA) antigen has been developed using immunoaffinity purified antibody. Various treatments enhanced the detection of tPA antigen in the plasma samples. Maximum detection was obtained by acidification of plasma to pH 4.8 to 6.5 or addition of 0.5 mol/L of L-lysine or L-arginine. Acidification or addition of lysine to plasma is also required for maximum immunoadsorption of plasma tPA antigen on anti-tPA-Ig-sepharose. These results indicate that plasma tPA antigen is partially cryptic to antibody in untreated plasma. The plasma tPA antigen isolated by immunoadsorption of either untreated plasma or acidified plasma on anti-tPA-Ig-sepharose consists mainly of a 100-kd plasminogen activator species as determined by fibrin-agar zymography. The 100-kd activity is possibly a tPA:inhibitor complex. A standardized sample preparation method was conveniently adopted by mixing 3 vol of plasma and 1 vol of 2 mol/L of L-lysine for the assay. Reconstitution and recovery studies showed that the method is specific and permits full detection of both free tPA and tPA:inhibitor complex. The validity of the assay is further supported by the finding that the spontaneous plasma fibrinolysis previously demonstrated to be dependent on plasma tPA antigen is correlated with tPA antigen content. Using the standardized assay, we found that tPA antigen concentrations in 16 blood bank plasmas are equivalent to 3.7 to 20 ng of 60 kd tPA/mL. In all the plasma tested, more than half of the antigen is undetected unless the plasma is treated as described above
Energy Technology Data Exchange (ETDEWEB)
Wun, T.C.; Capuano, A.
1987-05-01
A two-site immunoradiometric assay for tissue plasminogen activator (tPA) antigen has been developed using immunoaffinity purified antibody. Various treatments enhanced the detection of tPA antigen in the plasma samples. Maximum detection was obtained by acidification of plasma to pH 4.8 to 6.5 or addition of 0.5 mol/L of L-lysine or L-arginine. Acidification or addition of lysine to plasma is also required for maximum immunoadsorption of plasma tPA antigen on anti-tPA-Ig-sepharose. These results indicate that plasma tPA antigen is partially cryptic to antibody in untreated plasma. The plasma tPA antigen isolated by immunoadsorption of either untreated plasma or acidified plasma on anti-tPA-Ig-sepharose consists mainly of a 100-kd plasminogen activator species as determined by fibrin-agar zymography. The 100-kd activity is possibly a tPA:inhibitor complex. A standardized sample preparation method was conveniently adopted by mixing 3 vol of plasma and 1 vol of 2 mol/L of L-lysine for the assay. Reconstitution and recovery studies showed that the method is specific and permits full detection of both free tPA and tPA:inhibitor complex. The validity of the assay is further supported by the finding that the spontaneous plasma fibrinolysis previously demonstrated to be dependent on plasma tPA antigen is correlated with tPA antigen content. Using the standardized assay, we found that tPA antigen concentrations in 16 blood bank plasmas are equivalent to 3.7 to 20 ng of 60 kd tPA/mL. In all the plasma tested, more than half of the antigen is undetected unless the plasma is treated as described above.
Directory of Open Access Journals (Sweden)
Jaiswal Virendra
2012-08-01
Full Text Available Abstract Background Diagnosis of amoebic liver abscess (ALA in patients on anti-amoebic drugs is difficult. There is scanty data on this issue using Entamoeba histolytica (E. histolytica lectin antigen and polymerase chain reaction (PCR. We studied utility of lectin antigen, PCR, and IgG antibody in diagnosis of liver abscess in patients on anti-amoebic treatment. Liver aspirate of 200 patients, of which 170 had anti-amoebic drug prior to drainage, was tested for E. histolytica lectin antigen by (ELISA, PCR, bacterial culture, and serum IgG antibody by (ELISA. Classification of abscesses was based on result of anti-amoebic IgG antibody and bacterial culture, E. histolytica PCR and bacterial culture, and E. histolytica lectin antigen and bacterial culture. Findings Using anti-amoebic IgG antibody and bacterial culture, 136/200 (68.0% were classified as ALA, 12/200 (6.0% as pyogenic liver abscess (PLA, 29/200 (14.5% as mixed infection, and 23/200 (11.5% remained unclassified. Using amoebic PCR and bacterial culture 151/200 (75.5% were classified as ALA, 25/200 (12.5% as PLA, 16/200 (8.0% as mixed infection, and 8/200 (4.0% remained unclassified. With E. histolytica lectin antigen and bacterial culture, 22/200 (11.0% patients were classified as ALA, 39/200 (19.5% as PLA, 2/200 (1.0% as mixed infection, and 137/200 (68.5% remained unclassified. Conclusions E. histolytica lectin antigen was not suitable for classification of ALA patients who had prior anti-amoebic treatment. However, PCR may be used as alternative test to anti-amoebic antibody in diagnosis of ALA.
Seenivasan, Rajesh; Singh, Chandra K; Warrick, Jay W; Ahmad, Nihal; Gunasekaran, Sundaram
2017-09-15
An optically transparent patterned indium tin oxide (ITO) three-electrode sensor integrated with a microfluidic channel was designed for label-free immunosensing of prostate-specific membrane antigen (PSMA), a prostate cancer (PCa) biomarker, expressed on prostate tissue and circulating tumor cells but also found in serum. The sensor relies on cysteamine capped gold nanoparticles (N-AuNPs) covalently linked with anti-PSMA antibody (Ab) for target specificity. A polydimethylsiloxane (PDMS) microfluidic channel is used to efficiently and reproducibly introduce sample containing soluble proteins/cells to the sensor. The PSMA is detected and quantified by measuring the change in differential pulse voltammetry signal of a redox probe ([Fe(CN) 6 ] 3- /[Fe(CN) 6 ] 4- ) that is altered upon binding of PSMA with PSMA-Ab immobilized on N-AuNPs/ITO. Detection of PSMA expressing cells and soluble PSMA was tested. The limit of detection (LOD) of the sensor for PSMA-based PCa cells is 6/40µL (i.e., 150 cells/mL) (n=3) with a linear range of 15-400 cells/40µL (i.e., 375-10,000 cells/mL), and for the soluble PSMA is 0.499ng/40µL (i.e., 12.5ng/mL) (n=3) with the linear range of 0.75-250ng/40µL (i.e., 19-6250ng/mL), both with an incubation time of 10min. The results indicate that the sensor has a suitable sensitivity and dynamic range for routine detection of PCa circulating tumor cells and can be adapted to detect other biomarkers/cancer cells. Copyright © 2017 Elsevier B.V. All rights reserved.
A novel one-step Helicobacter pylori saliva antigen test.
Yang, Bi-Ling; Yeh, Chun; Kwong, Wei-Gang; Lee, Shou-Dong
2015-02-01
A rapid, reliable, and sufficiently accurate test for diagnosing Helicobacter pylori infection is required for screening dyspeptic patients before a referral for endoscopy. The purpose of this article is two-fold: first, to evaluate the accuracy of a one-step H. pylori saliva antigen (HPS) test; and second, to compare noninvasive and invasive H. pylori tests in Taiwanese population. A total of 104 consecutive dyspeptic patients admitted for gastroenterology into the outpatient department underwent a one-step HPS test, rapid urease test, histology, and (13)C-urea breath test (13)C-UBT (proto C-13 urea kit). The accuracy of the HPS test was compared with a gold standard defined by at least two positive H. pylori test results from three H. pylori tests (histology, rapid urease test, and (13)C-UBT). The 104 patients eligible for analysis (mean age: 58 years, range 22-87 years), 21 (20%) were gold standard positive. Among them, the positive of the one-step H. pylori saliva Ag test, rapid urease test, (13)C-UBT, histology were (52; 50%), (17; 16%), (27; 25%) and (22; 21%) respectively. The sensitivity and specificity of the HPS tests, rapid urease test, (13)C-UBTs, and histology were 71.43% and 55.42%, 76.19% and 98.80%, 100% and 92.77%, and 85.71% and 95.18%, respectively, relative to the gold standard. The one-step HPS test exhibited a sensitivity of 71.43%, nearly equivalent to that of the rapid urea test. The one-step HPS test exhibited a high sensitivity and low specificity compared with the other tests, indicating that it is not sufficiently accurate for use in a clinical setting for diagnosing H. pylori infection. However, the test is simple to use (requiring only a saliva sample), inexpensive, and noninvasive in its application, and thus appealing for use in population-based prevalence surveys of the epidemiology of H. pylori infection. Copyright © 2014. Published by Elsevier Taiwan.
Alvarez, Josep; Domínguez, Angela; Sabrià, Miquel; Ruiz, Laura; Torner, Nuria; Cayla, Joan; Barrabeig, Irene; Sala, M Rosa; Godoy, Pere; Camps, Neus; Minguell, Sofia
2009-11-01
To describe the characteristics of community outbreaks of legionellosis in Catalonia, Spain from 1990 to 2004, to compare two time periods (1990-1996 and 1997-2004), and to assess the influence of outbreak characteristics on the case fatality rate (CFR). This is a descriptive analysis of the outbreaks detected by epidemiological surveillance units in Catalonia. Variables potentially related to the CFR were analyzed by logistic regression. Of the 118 outbreaks involving 690 patients (overall CFR 4.5%), the urinary antigen test (UAT) was used for first case diagnosis in 80.5%. The origin of the outbreak was identified as a cooling tower in 35.6%, as a water distribution system in a public building in 14.4%, and a water distribution system at other sites in 7.6%. Statistically significant differences were found in the CFR (12.2% vs. 3.9%; p=0.018) and detection of the first case by UAT (0.0% vs. 87.2%; pcases involved in outbreaks of legionellosis.
Directory of Open Access Journals (Sweden)
Panigrahi Rajesh
2010-08-01
Full Text Available Abstract Background Occult hepatitis B virus (HBV infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. Methods A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT for detection of occult HBV infection and surface gene was analyzed after direct sequencing. Results A total of 220 (30.1% HBsAg negative donors were antiHBc positive, of them 66 (30% were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3% was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Conclusion Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India.
Panigrahi, Rajesh; Biswas, Avik; Datta, Sibnarayan; Banerjee, Arup; Chandra, Partha K; Mahapatra, Pradip K; Patnaik, Bharat; Chakrabarti, Sekhar; Chakravarty, Runu
2010-08-27
Occult hepatitis B virus (HBV) infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg) testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT) for detection of occult HBV infection and surface gene was analyzed after direct sequencing. A total of 220 (30.1%) HBsAg negative donors were antiHBc positive, of them 66 (30%) were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3%) was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India.
Tamboli, Vibha K; Bhalla, Nikhil; Jolly, Pawan; Bowen, Chris R; Taylor, John T; Bowen, Jenna L; Allender, Chris J; Estrela, Pedro
2016-12-06
The study reports the use of extended gate field-effect transistors (FET) for the label-free and sensitive detection of prostate cancer (PCa) biomarkers in human plasma. The approach integrates for the first time hybrid synthetic receptors comprising of highly selective aptamer-lined pockets (apta-MIP) with FETs for sensitive detection of prostate specific antigen (PSA) at clinically relevant concentrations. The hybrid synthetic receptors were constructed by immobilizing an aptamer-PSA complex on gold and subjecting it to 13 cycles of dopamine electropolymerization. The polymerization resulted in the creation of highly selective polymeric cavities that retained the ability to recognize PSA post removal of the protein. The hybrid synthetic receptors were subsequently used in an extended gate FET setup for electrochemical detection of PSA. The sensor was reported to have a limit of detection of 0.1 pg/mL with a linear detection range from 0.1 pg/mL to 1 ng/mL PSA. Detection of 1-10 pg/mL PSA was also achieved in diluted human plasma. The present apta-MIP sensor developed in conjunction with FET devices demonstrates the potential for clinical application of synthetic hybrid receptors for the detection of clinically relevant biomarkers in complex samples.
Emmerich, Petra; Mika, Angela; von Possel, Ronald; Rackow, Anne; Liu, Yang; Schmitz, Herbert; Sherifi, Kurtesh; Halili, Barie; Jakupi, Xhevat; Berisha, Lindita; Ahmeti, Salih
2018-01-01
As the most widespread tick-borne arbovirus causing infections in numerous countries in Asia, Africa and Europe, Crimean-Congo Hemorrhagic Fever Virus (CCHFV, family Nairoviridae) was included in the WHO priority list of emerging pathogens needing urgent Research & Development attention. To ensure preparedness for potential future outbreak scenarios, reliable diagnostic tools for identification of acute cases as well as for performance of seroprevalence studies are necessary. Here, the CCHFV ortholog of the major bunyavirus antigen, the nucleoprotein (NP), was recombinantly expressed in E.coli, purified and directly labeled with horseradish peroxidase (HRP). Employing this antigen, two serological tests, a μ-capture ELISA for the detection of CCHFV-specific IgM antibodies (BLACKBOX CCHFV IgM) and an IgG immune complex (IC) ELISA for the detection of CCHFV-specific IgG antibodies (BLACKBOX CCHFV IgG), were developed. Test performance was evaluated and compared with both in-house gold standard testing by IgM/IgG indirect immunofluorescence (IIF) and commercially available ELISA tests (VectoCrimean-CHF-IgM/IgG, Vector-Best, Russia) using a serum panel comprising paired samples collected in Kosovo during the years 2013–2016 from 15 patients with an acute, RT-PCR-confirmed CCHFV infection, and 12 follow-up sera of the same patients collected approximately one year after having overcome the infection. Reliably detecting IgM antibodies in all acute phase sera collected later than day 4 after onset of symptoms, both IgM ELISAs displayed excellent diagnostic and analytical sensitivity (100%, 95% confidence interval (CI): 85.2%–100.0%). While both IgG ELISAs readily detected the high IgG titers present in convalescent patients approximately one year after having overcome the infection (sensitivity 100%, 95% CI: 73.5%–100.0%), the newly developed BLACKBOX CCHFV IgG ELISA was superior to the commercial IgG ELISA in detecting the rising IgG titers during the acute phase
Alvarado, Primavera; Ostos, Ana; Franquiz, Nohelys; Roschman-González, Antonio; Zambrano, Edgar A; Mendoza, Mireya
2015-06-01
We developed and analyzed an Enzyme-Linked Immunosorbent Assay (ELISA) in order to detect antibodies in sera from sporotrichosis patients. We used a crude antigen of Sporothrix schenckii sensu stricto, obtained from the mycelial phase of the fungi. Positive sera were analyzed by other serological techniques such as double immunodiffusion (IGG) and counterimmunoelectrophoresis (CIE). The assay was validated by using sera from patients with other pathologies such as: histoplasmosis, paracoccidioidomycosis, tuberculosis, leishmaniasis, lupus and healthy individuals as negative controls. For the Sporothrix schenckii sensu stricto antigen, we found a 100% of specificity by every technique and sensitivity higher than 98% with IDD, CIE and ELISA. Our results show a high sensitivity and specificity for the Sporothrix schenckii sensu stricto antigen, so it can be used for IDD, CIE and ELISA. The results suggest that this antigen could be used in conjunction with other conventional tests for differential diagnosis and may be useful for monitoring the disease progression and response to treatment.
Energy Technology Data Exchange (ETDEWEB)
Zhang, Z.-G.; Hiromatsu, Y.; Salvi, M.; Triller, H.; Bernard, N.; Wall, J.R. (Thyroid Research Unit, The Montreal General Hospital Research Institute, Montreal, Quebec (Canada)); Medeiros-Neto, G.; Iacona, A.; Lima, N. (Thyroid Clinic, Hospital das Clinicas, Sao Paulo (Brazil))
1989-01-01
We have studied the prevalence and significance of cytotoxic antibodies against human eye muscle cells, as detected in antibody-dependent cell-mediated cytotoxicity (ADCC) and complement-mediated antibody-dependent cytotoxicity (CMAC) in {sup 51}Cr release assays, in patients with Graves' ophthalmopathy or Hashimoto's thyroiditis. A high prevalence of positive ADCC tests was found in all groups of patients with ophthalmopathy tested. Tests were positive in 64% of patients with Graves' ophthalmopathy from an area of severe iodine deficiency (Sao Paulo) and in 64% of such patients from an iodine replete area (Montreal). In patients with so-called ''euthyroid ophthalmopathy'', i.e. eye disease associated with thyroiditis, ADCC tests were positive in 75 and 38% of patients from the two areas, respectively, while tests were positive in 40 and 22%, respectively, of patients with Graves' hyperthyroidism without evident eye disease. In normal subjects, levels of {sup 51}Cr release was always at background levels. In a group of patients from the high-iodine area, levels of antibodies in ADCC correlated positively with the intraocular pressure (mmHg) in primary position as a parameter of eye muscle dysfunction. In patients with ophthalmopathy, positive ADCC tests were assciated with antibodies to eye muscle membrane antigens of 55,65 and 95 kD as detected by immunoblotting, although the correlation was not close for any antigen. in contrast, CMAC tests were negative in all patients with ophthalmopathy. We also tested 9 mouse and 10 human monoclonal antibodies, reactive with orbital antigens in an enzyme-linked immunosorbent assay, for cytotoxic activity, in ADCC and CMAC, against eye muscle and thyroid cells. All monoclonal antibodies were of the IgM class and negative in ADCC assays. (Abstract Truncated)
Onodera, Rie; Kurita, Emi; Taniguchi, Kikuyo; Karakawa, Shuhei; Okada, Satoshi; Kihara, Hirotaka; Fujii, Teruhisa; Kobayashi, Masao
2017-11-01
Anti-human neutrophil antigen (HNA) antibodies have been implicated in the development of neonatal alloimmune neutropenia (NAN) and autoimmune neutropenia (AIN). There are many conventional assay methods that detect anti-HNA antibodies. However, a method to measure multiple samples and detect several anti-HNA antibodies simultaneously is needed. We developed a new method, the extracted granulocyte antigen immunofluorescence assay (EGIFA), to analyze anti-HNA-1a, -1b, and -2 antibodies in sera. The results obtained by EGIFA were evaluated in comparison with those from several standard assay methods. Anti-HNA antibodies in serum samples from nine familial cases with suspected NAN (n = 19) and children with suspected AIN (n = 88) were also measured by EGIFA. The evaluation of nine serum samples with anti-HNA antibodies suggested that EGIFA demonstrated equivalent specificity and superior sensitivity to monoclonal antibody-specific immobilization of granulocyte antigens and had comparable sensitivity to the granulocyte indirect immunofluorescence test. EGIFA successfully detected anti-HNA-1a or -1b antibodies in seven of nine familial cases with suspected NAN. EGIFA detected anti-HNA antibodies in 40.9% of children with suspected AIN. Among them, isolated anti-HNA-1a or -1b antibody was detected in 4.5 or 12.5% of children, respectively, and anti-HNA-2 antibody was identified in 3.4% of children. The 30.8% (16 of 52) of children negative for anti-HNA antibody by EGIFA were positive for anti-HLA antibody. EGIFA facilitated the measurement of anti-HNA-1a, -1b, and/or -2 antibodies in sera. The prompt measurement of anti-HNA antibodies will improve the diagnosis and clinical management of patients with suspected NAN or AIN. © 2017 AABB.
Specific binding-adsorbent assay method and test means
International Nuclear Information System (INIS)
1981-01-01
A description is given of an improved specific binding assay method and test means employing a nonspecific adsorbent for the substance to be determined, particularly hepatitis B surface (HBsub(s)) antigen, in its free state or additionally in the form of its immune complex. The invention is illustrated by 1) the radioimmunoadsorbent assay for HBsub(s) antigen, 2) the radioimmunoadsorbent assay for HBsub(s) antigen in the form of immune complex with antibody, 3) a study of adsorption characteristics of various anion exchange materials for HBsub(s) antigen, 4) the use of hydrophobic adsorbents in a radioimmunoadsorbent assay for HBsub(s) antigen and 5) the radioimmunoadsorbent assay for antibody to HBsub(s) antigen. The advantages of the present method for detecting HBsub(s) antigen compared to previous methods include the manufacturing advantages of eliminating the need for insolubilised anti-HBsub(s) and the advantages of a single incubation step, fewer manipulations, storability of adsorbent materials, increased sensitivity and versatility of detecting HBsub(s) antigen in the form of its immune complex if desired. (U.K.)
Identification of antigenic proteins of setaria cervi by immunoblotting technique
International Nuclear Information System (INIS)
Kaushal, N.A.; Kaushal, D.C.; Ghatak, S.
1987-01-01
Identification and characterization of antigenic proteins of Setaria cervi (bovine filarial parasite) adults and microfilariae was done by immunoblotting technique using hyperimmune rabbit sera against S. cervi and Brugia malayi. The antigens recognized by these sera were detected by using 125 I protein-A followed by autoradiography. Fifteen different antigens were observed to be common between adult and microfilarial stages of the parasite. Some stage specific antigens were also identified. Many antigens of S. cervi adults and microfilariae were also recognized by rabbit anti-B.malayi serum showing the existence of common antigenic determinants between the bovine and human filarial parasites
Use of synthetic, crystalline, L-α-dimyristoyl lecithin in cardiolipin antigens
Reyn, Alice; Bentzon, Michael Weis
1956-01-01
Experiments were carried out by the authors to determine whether synthetic, crystalline, L-α-dimyristoyl lecithin could replace natural purified lecithins in the preparation of cardiolipin antigens. These experiments were designed specifically to find out whether it was possible to obtain the same serological reactions, qualitatively and quantitatively, with the test antigen as with a reference antigen containing natural lecithin, and whether the test antigen had the same keeping qualities as the reference antigen. The tests used were the quantitative complement-fixation test as modified by Mørch in 1933, and the VDRL slide flocculation test. The results showed that synthetic, crystalline, L-α-dimyristoyl lecithin could replace natural lecithin in the preparation of cardiolipin antigens, but that the antigens prepared with the synthetic lecithin were significantly less sensitive than those prepared with an equimolar amount of natural lecithin. The authors consider that further investigation is required before the use of synthetic lecithin is finally adopted. PMID:13342931
Wood, M M; Timms, P
1992-01-01
Chlamydia psittaci is the major cause of infectious disease in the koala (Phascolarctos cinereus). It causes four disease syndromes in the koala, namely, conjunctivitis, rhinitis, cystitis, and infertility (females only). Diagnosis of chlamydial infections in koalas relies primarily on isolation of the organism in cell culture. Serology has generally not been useful, and little use has previously been made of the commercially available antigen detection kits. We examined the sensitivity, spec...
DEFF Research Database (Denmark)
Sørensen, Caspar G; Karlsson, William K; Pommergaard, Hans-Christian
2016-01-01
INTRODUCTION: Carcinoembryonic Antigen (CEA) has been used as a tumor marker in the follow-up of colorectal cancer for more than 40 years. Controversy exists regarding its diagnostic applicability due to a relatively low sensitivity and a questionable effect on mortality. The aim of this review...... was to assess the diagnostic accuracy of CEA in detecting recurrence after intended curative surgery for primary colorectal cancer. METHODS: Systematic literature searches were performed in PubMed, EMBASE and Cochrane databases, and articles were chosen based on predefined inclusion criteria. Reference lists...
Directory of Open Access Journals (Sweden)
Om Parkash
2014-11-01
Full Text Available An electrochemical immunosensor modified with the streptavidin/biotin system on screen printed carbon electrodes (SPCEs for the detection of the dengue NS1 antigen was developed in this study. Monoclonal anti-NS1 capture antibody was immobilized on streptavidin-modified SPCEs to increase the sensitivity of the assay. Subsequently, a direct sandwich enzyme linked immunosorbent assay (ELISA format was developed and optimized. An anti-NS1 detection antibody conjugated with horseradish peroxidase enzyme (HRP and 3,3,5,5'-tetramethybezidine dihydrochloride (TMB/H2O2 was used as an enzyme mediator. Electrochemical detection was conducted using the chronoamperometric technique, and electrochemical responses were generated at −200 mV reduction potential. The calibration curve of the immunosensor showed a linear response between 0.5 µg/mL and 2 µg/mL and a detection limit of 0.03 µg/mL. Incorporation of a streptavidin/biotin system resulted in a well-oriented antibody immobilization of the capture antibody and consequently enhanced the sensitivity of the assay. In conclusion, this immunosensor is a promising technology for the rapid and convenient detection of acute dengue infection in real serum samples.
Pedersen, Ronnie O; Peters, Tim; Panda, Rakhi; Wehling, Paul; Garber, Eric A E
2017-07-01
A shipment of imported garlic powder was suspected of containing peanut. Samples (subs) collected from the shipment displayed considerable variability in peanut antigenicity when analyzed by enzyme-linked immunosorbent assay (ELISA). This raised questions regarding whether peanut was actually present, the amount present, and the basis for the variability in antigenic content. Analyses that used an xMAP multiplex assay for the detection of peanut and additional food allergens generated responses that were characteristic of peanut. Specifically, the relative intensities of two different peanut-specific antibodies coupled to beads (peanut-37 and -38) and the antigen profiles were identical to garlic controls spiked with peanut. In addition, the xMAP data did not indicate the presence of other allergens. Quantitative analyses indicated an approximately fivefold variation in peanut concentration among different subs. In contrast, within a sub, the apparent peanut concentration appeared constant. Particle size analyses of the garlic powder subs indicated a single distribution profile, with a peak at 380 μm. ELISA analysis of sieve-fractionated garlic powder from one of the subs indicated that slightly less than half of the detectable peanut was smaller than 212 μm, with the remainder almost evenly split between 212 and 300 μm and >300 μm. Modeling to predict possible oral exposure levels of peanut other than those directly measured requires additional research on the physicochemical properties of peanut and garlic, along with information on the production of the garlic powder.
International Nuclear Information System (INIS)
Tewelde, N.; Kebede, A.; Tsegaye, A.
1997-01-01
Blood and serum samples were collected from a tsetse free zone in the central highlands of Ethiopia. The samples were collected to determine the specificity and establish percentage positivity cut-off points of the antigen ELISA. Blood samples collected from these areas were negative for trypanosomosis using Standard Trypanosome Detection Methods (STDM). Ag-ELISA, in contrast, detected circulating trypanosomal antigens in 7.6% of the serum samples collected. Similarly, samples were collected from a tsetse infested zone in the upper Didessa valley, western Ethiopia, to assess the sensitivity of the Ag-ELISA. STDM detected trypanosomal infections in the range of 15.8 and 16.7% of blood samples from this zone. On the other hand, Ag-ELISA, indicated the presence of circulating trypanosomal antigens in 38.6% of serum samples tested. Moreover, Ag-ELISA was used to monitor the effectiveness of a tsetse control campaign in the upper Didessa valley. There were great differences in the prevalence rates of trypanosomosis, as revealed by the STDM and Ag-ELISA, between the tsetse controlled and tsetse infested zones of the upper Didessa valley. Generally, the Ag-ELISA revealed the presence of circulating trypanosomal antigens in only 43.7% of patent infections. Nevertheless, the test detected 318 more cases which were not diagnosed by any one of the STDM used. More interestingly, Ag-ELISA indicated the widespread presence of T. brucei in the cattle sampled in all zones. (author). 11 refs, 4 tabs
Energy Technology Data Exchange (ETDEWEB)
Tewelde, N; Kebede, A; Tsegaye, A [National Tsetse and Trypanosomiasis Investigation and Control Centre (NTTICC), Bedelle (Ethiopia)
1997-02-01
Blood and serum samples were collected from a tsetse free zone in the central highlands of Ethiopia. The samples were collected to determine the specificity and establish percentage positivity cut-off points of the antigen ELISA. Blood samples collected from these areas were negative for trypanosomosis using Standard Trypanosome Detection Methods (STDM). Ag-ELISA, in contrast, detected circulating trypanosomal antigens in 7.6% of the serum samples collected. Similarly, samples were collected from a tsetse infested zone in the upper Didessa valley, western Ethiopia, to assess the sensitivity of the Ag-ELISA. STDM detected trypanosomal infections in the range of 15.8 and 16.7% of blood samples from this zone. On the other hand, Ag-ELISA, indicated the presence of circulating trypanosomal antigens in 38.6% of serum samples tested. Moreover, Ag-ELISA was used to monitor the effectiveness of a tsetse control campaign in the upper Didessa valley. There were great differences in the prevalence rates of trypanosomosis, as revealed by the STDM and Ag-ELISA, between the tsetse controlled and tsetse infested zones of the upper Didessa valley. Generally, the Ag-ELISA revealed the presence of circulating trypanosomal antigens in only 43.7% of patent infections. Nevertheless, the test detected 318 more cases which were not diagnosed by any one of the STDM used. More interestingly, Ag-ELISA indicated the widespread presence of T. brucei in the cattle sampled in all zones. (author). 11 refs, 4 tabs.
Enhanced specificity in immunoscreening of expression cDNA clones using radiolabeled antigen overlay
International Nuclear Information System (INIS)
Chao, S.; Chao, L.; Chao, J.
1989-01-01
A highly sensitive and specific method has been developed for immunoscreening clones from an expression cDNA library. The procedures utilize a radiolabeled antigen detection method described originally for the immunoblotting of plasma proteins. Screening of rat alpha 1-antitrypsin clones was used. Comparison between Western blots of alpha 1-antitrypsin using both labeled antigen and protein A detection methods showed that the former yielded lower background and greater sensitivity than the latter. Further, this technique was shown to have a lower detection limit of less than 20 ng through Western blot analysis of varying concentrations of alpha 1-antitrypsin. The procedures are based on the expression of the protein by cDNA clones containing the DNA inserts in the correct reading frame. Following the transfer of phage proteins to nitrocellulose membranes, the bivalent antibodies bind monovalently to both nitrocellulose-bound-antigen in the phage lysates and radiolabeled antigen. The radiolabeled antigen overlay method is superior to the protein A detection method in sensitivity, specificity and reproducibility. This improved method can be applied in general for screening expression cDNA libraries, provided that the specific antiserum and radiolabeled antigen are available
Directory of Open Access Journals (Sweden)
Libertad Alzamora-Gonzales
2016-05-01
Full Text Available Fasciolosis is a cosmopolitan parasitosis medical-veterinary importance caused by Fasciola hepatica, which affects sheep, goats and cattle; and it affects man accidentally causing an epidemic-endemic infection difficult to diagnose. The aim was to develop an indirect sandwich ELISA with 3 antibodies for detecting excretory-secretory antigens of Fasciola hepatica (ESFh. For the development of indirect sandwich ELISA were used, as capture antibody, mouse polyclonal antibodies anti ESFh and polyclonal antibodies rabbit anti-ESFh as detection antibody, at the concentrations of 10 and 5 µg/mL respectively. The conjugate used was mouse monoclonal anti- total immunoglobulins rabbit linked to peroxidase (1/1000. Were analized 31 sheep fecal samples, and the results were compared with those obtained by direct coproparasitological examination (DC and counterimmunoelectrophoresis (CIEP. The detection limit obtained for indirect sandwich ELISA was 100 ng/mL. The test had a 100% sensitivity, 96.6% specificity, positive and negative predictive values of 50% and 96.6% respectively, in relation to DC test. Comparing with CIEP the specificity obtained for indirect sandwich ELISA was 93.5% and a negative predictive value of 100%. We concluded that indirect sandwich ELISA designed is able to detect metabolic antigens in ovine feces samples and can be used for Fasciola hepatica diagnosis.
EVALUATION OF AN O-ANTIGEN ELISA FOR SCREENING CATTLE HERDS FOR SALMONELLA-TYPHIMURIUM
DEFF Research Database (Denmark)
Hoorfar, Jeffrey; Bitsch, V.
1995-01-01
A total of 2585 serum samples from 62 dairy herds located in four different regions of Denmark were tested in an O-antigen (0:1,4,5,12)-based ELISA for the detection of antibodies against Salmonella typhimurium. Ten closed herds from an island with no reported occurrence of salmonellosis for seve......A total of 2585 serum samples from 62 dairy herds located in four different regions of Denmark were tested in an O-antigen (0:1,4,5,12)-based ELISA for the detection of antibodies against Salmonella typhimurium. Ten closed herds from an island with no reported occurrence of salmonellosis...... for several years, and 12 herds from a salmonella enzootic area which had had clinical outbreaks of S typhimurium were used to define a herd ELISA cut-off value. When herds with at least 5 per cent of the serum samples having an optical density of >0.5 were considered ELISA-positive, all 10 herds from...... the salmonellosis-free island were ELISA-negative, and all but one of the 12 S typhimurium-infected herds were ELISA-positive, which resulted in a herd test sensitivity of 0.92 and herd test specificity of 1.0. Eleven of the 12 S typhimurium-infected herds were negative in a blocking ELISA based on a monoclonal...
Schmitz, H
1981-01-01
An improved fixation method for antigen detection in lymphoblastoid cells is described. Herpesvirus papio nuclear antigen (HUPNA) could be stained in several transformed lymphoid cell lines by anti-complement immunofluorescence (ACIF). Antibody to HUPNA was detected in many human sera containing antibodies to Epstein-Barr virus capsid and nuclear antigen (EBNA). Rheumatoid arthritis sera showed a high incidence of both anti-EBNA and anti-HUPNA antibodies.
Energy Technology Data Exchange (ETDEWEB)
Zou, Zhexiang; Wang, Jun; Wang, Hua; Li, Yao Q.; Lin, Yuehe
2012-05-30
A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population
Natural selection promotes antigenic evolvability.
Graves, Christopher J; Ros, Vera I D; Stevenson, Brian; Sniegowski, Paul D; Brisson, Dustin
2013-01-01
The hypothesis that evolvability - the capacity to evolve by natural selection - is itself the object of natural selection is highly intriguing but remains controversial due in large part to a paucity of direct experimental evidence. The antigenic variation mechanisms of microbial pathogens provide an experimentally tractable system to test whether natural selection has favored mechanisms that increase evolvability. Many antigenic variation systems consist of paralogous unexpressed 'cassettes' that recombine into an expression site to rapidly alter the expressed protein. Importantly, the magnitude of antigenic change is a function of the genetic diversity among the unexpressed cassettes. Thus, evidence that selection favors among-cassette diversity is direct evidence that natural selection promotes antigenic evolvability. We used the Lyme disease bacterium, Borrelia burgdorferi, as a model to test the prediction that natural selection favors amino acid diversity among unexpressed vls cassettes and thereby promotes evolvability in a primary surface antigen, VlsE. The hypothesis that diversity among vls cassettes is favored by natural selection was supported in each B. burgdorferi strain analyzed using both classical (dN/dS ratios) and Bayesian population genetic analyses of genetic sequence data. This hypothesis was also supported by the conservation of highly mutable tandem-repeat structures across B. burgdorferi strains despite a near complete absence of sequence conservation. Diversification among vls cassettes due to natural selection and mutable repeat structures promotes long-term antigenic evolvability of VlsE. These findings provide a direct demonstration that molecular mechanisms that enhance evolvability of surface antigens are an evolutionary adaptation. The molecular evolutionary processes identified here can serve as a model for the evolution of antigenic evolvability in many pathogens which utilize similar strategies to establish chronic infections.
Natural selection promotes antigenic evolvability.
Directory of Open Access Journals (Sweden)
Christopher J Graves
Full Text Available The hypothesis that evolvability - the capacity to evolve by natural selection - is itself the object of natural selection is highly intriguing but remains controversial due in large part to a paucity of direct experimental evidence. The antigenic variation mechanisms of microbial pathogens provide an experimentally tractable system to test whether natural selection has favored mechanisms that increase evolvability. Many antigenic variation systems consist of paralogous unexpressed 'cassettes' that recombine into an expression site to rapidly alter the expressed protein. Importantly, the magnitude of antigenic change is a function of the genetic diversity among the unexpressed cassettes. Thus, evidence that selection favors among-cassette diversity is direct evidence that natural selection promotes antigenic evolvability. We used the Lyme disease bacterium, Borrelia burgdorferi, as a model to test the prediction that natural selection favors amino acid diversity among unexpressed vls cassettes and thereby promotes evolvability in a primary surface antigen, VlsE. The hypothesis that diversity among vls cassettes is favored by natural selection was supported in each B. burgdorferi strain analyzed using both classical (dN/dS ratios and Bayesian population genetic analyses of genetic sequence data. This hypothesis was also supported by the conservation of highly mutable tandem-repeat structures across B. burgdorferi strains despite a near complete absence of sequence conservation. Diversification among vls cassettes due to natural selection and mutable repeat structures promotes long-term antigenic evolvability of VlsE. These findings provide a direct demonstration that molecular mechanisms that enhance evolvability of surface antigens are an evolutionary adaptation. The molecular evolutionary processes identified here can serve as a model for the evolution of antigenic evolvability in many pathogens which utilize similar strategies to establish
Shortliffe, L M; Wehner, N; Stamey, T A
1981-01-01
The prostatic fluid of two patients with Escherichia coli bacterial prostatitis was analyzed for evidence of a local immune response to bacterial infection. A solid-phase radioimmunoassay was modified to measure the immunoglobulin (Ig)A and IgG antigen-specific antibody responses to infecting bacteria in serum and prostatic fluid from patient. Formalin-fixed whole E. coli were used as antigen. In one patient with acute E. coli prostatic infection, measurements of antigen-specific antibody con...
Evans, R.; Joseph-Williams, N.; Edwards, A.; Newcombe, R.G.; Wright, P.; Kinnersley, P.; Griffiths, J.; Jones, M.; Williams, J.; Grol, R.P.T.M.; Elwyn, G.
2010-01-01
BACKGROUND: Men considering the prostate specific antigen (PSA) test for prostate cancer, an increasingly common male cancer, are encouraged to make informed decisions, as the test is limited in its accuracy and the natural history of the condition is poorly understood. The Web-based PSA decision
Yan, Xinyu; Wang, Kan; Lu, Wenting; Qin, Weijian; Cui, Daxiang; He, Jinghua
2016-03-01
Carbohydrate antigen 72-4 (CA72-4) is an important biomarker associated closely with diagnosis and prognosis of early gastric cancer. How to realize quick, sensitive, specific, and quantitative detection of CA72-4 in clinical specimens has become a great requirement. Herein, we reported a CdSe/ZnS quantum dot-labeled lateral flow test strip combined with a charge-coupled device (CCD)-based reader was developed for rapid, sensitive, and quantitative detection of CA72-4. Two mouse monoclonal antibodies (mAbs) against CA72-4 were employed. One of them was coated as a test line, while another mAb was labeled with quantum dots and coated onto conjugate pad. The goat anti-mouse IgG was immobilized as a control line. After sample was added, a sandwich structure was formed with CA72-4 and these two mAbs. The fluorescent signal from quantum dots (QD)-labeled mAb in sandwich structure was related to the amount of detected CA72-4. A CCD-based reader was used to realize quantitative detection of CA72-4. Results showed that developed QD-labeled lateral flow strips to detect CA72-4 biomarker with the sensitivity of 2 IU/mL and 10 min detection time. One hundred sera samples from clinical patients with gastric cancer and healthy people were used to confirm specificity of this strip method; results showed that established strip method own 100 % reproducibility and 100 % specificity compared with Roche electrochemiluminescence assay results. In conclusion, CdSe/ZnS quantum dot-labeled lateral flow strips for detection of CA72-4 could realize rapid, sensitive, and specific detection of clinical samples and could own great potential in clinical translation in near future.
International Nuclear Information System (INIS)
Dwinger, R.H.; Rebeski, D.; Winger, E.
1997-01-01
Monoclonal antibodies directed at epitopes of Trypanosoma brucei, T. congolense and T. vivax have been used to capture and detect trypanosomal antigens in bovine blood samples using an enzyme-linked immunosorbent assay (ELISA) developed elsewhere. The test has been transformed in a ready-to-use kit format for distribution among a network of 15 African research institutes. The specificity of the test was assessed under experimental and field conditions and found to be 96% (± 2%) for T. brucei, 99.5% (±1%) for T. congolense and 99% (±1%) for T. vivax. Following a validation period under field conditions, adjustments were made to the protocol to increase the sensitivity of the ELISA and to improve the suitability of the test for laboratory use under African conditions. Presently the ag-ELISA is being applied in conjunction with conventional parasitological techniques such as the buffy coat technique (BCT) to monitor progress in various tsetse and trypanosomosis control programmes and in a tsetse eradication effort in the United Republic of Tanzania, on the island of Zanzibar. The two tests complement each other, since infections not detected by one test may be detected by the other. In general, the serological test tends to produce more false negatives during subacute infections, while the parasitological techniques tend to produce more false negatives during chronic infections. Since the sensitivity of the ELISA is not optimal, research efforts at the FAO/IAEA Agriculture and Biotechnology Laboratory will be focused on improving this aspect. However, these efforts are severely hampered by the lack of a diagnostic test that can be used as a ''gold standard''. The use of the polymerase chain reaction for verifying doubtful test results and as a possible candidate for a ''gold standard'' to diagnose trypanosomosis are discussed. Finally, future plans are outlined to initiate the use of geographical information systems to assess the impact of tsetse control and
Fedele, Pasquale L; Wheeler, Michael; Lemoh, Christopher; Chunilal, Sanjeev
2014-10-01
Current screening guidelines for malaria in new refugees include a combination of thick and thin film examination and immunochromatographic antigen test (ICT). However, as the prevalence of malaria in our population has decreased due to changing refugee demographics, we sought to determine if an ICT alone can reliably exclude malaria in our asymptomatic refugee population.A retrospective analysis was conducted of all investigations for malaria performed from 1 August 2011 to 31 July 2013, including thick and thin blood film examination, BinaxNOW ICT, and external morphological and polymerase chain reaction (PCR) validation where applicable.Malaria was diagnosed in 45 of 1248 (3.6%) patients investigated, all of whom were symptomatic and the majority (71.1%) returned travellers. All 599 asymptomatic refugees screened were negative. Overall, 42 of 45 malaria cases were detected by the ICT; sensitivity 93.3% (95% CI 80.7-98.3%) and negative predictive value (NPV) 99.8% (99.2-99.9%). All 21 cases of Plasmodium falciparum and 20 of 22 cases of Plasmodium vivax were detected, giving a sensitivity of 100% (80.8-100%) and 90.9% (69.4-98.4%) respectively. Too few cases of Plasmodium malariae and no cases of Plasmodium ovale or Plasmodium knowlesi were diagnosed for adequate assessment to be carried out.These data suggest that full malaria screening in all asymptomatic refugees with the combination of thick and thin blood films and rapid antigen test may not be warranted. Alternative screening approaches should be considered, including the use of ICT alone, or limiting screening of asymptomatic refugees to only those originating from countries with high incidence of malaria.
A Bacterial Glycoengineered Antigen for Improved Serodiagnosis of Porcine Brucellosis.
Cortina, María E; Balzano, Rodrigo E; Rey Serantes, Diego A; Caillava, Ana J; Elena, Sebastián; Ferreira, A C; Nicola, Ana M; Ugalde, Juan E; Comerci, Diego J; Ciocchini, Andrés E
2016-06-01
Brucellosis is a highly zoonotic disease that affects animals and human beings. Brucella suis is the etiological agent of porcine brucellosis and one of the major human brucellosis pathogens. Laboratory diagnosis of porcine brucellosis mainly relies on serological tests, and it has been widely demonstrated that serological assays based on the detection of anti O-polysaccharide antibodies are the most sensitive tests. Here, we validate a recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of porcine brucellosis. An indirect immunoassay based on the detection of anti-O-polysaccharide IgG antibodies was developed coupling OAg-AcrA to enzyme-linked immunosorbent assay plates (glyco-iELISA). To validate the assay, 563 serum samples obtained from experimentally infected and immunized pigs, as well as animals naturally infected with B. suis biovar 1 or 2, were tested. A receiver operating characteristic (ROC) analysis was performed, and based on this analysis, the optimum cutoff value was 0.56 (relative reactivity), which resulted in a diagnostic sensitivity and specificity of 100% and 99.7%, respectively. A cutoff value of 0.78 resulted in a test sensitivity of 98.4% and a test specificity of 100%. Overall, our results demonstrate that the glyco-iELISA is highly accurate for diagnosis of porcine brucellosis, improving the diagnostic performance of current serological tests. The recombinant glycoprotein OAg-AcrA can be produced in large homogeneous batches in a standardized way, making it an ideal candidate for further validation as a universal antigen for diagnosis of "smooth" brucellosis in animals and humans. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Howe, Daniel K; Gaji, Rajshekhar Y; Marsh, Antoinette E; Patil, Bhagyashree A; Saville, William J; Lindsay, David S; Dubey, J P; Granstrom, David E
2008-05-01
A gene family of surface antigens is expressed by merozoites of Sarcocystis neurona, the primary cause of equine protozoal myeloencephalitis (EPM). These surface proteins, designated SnSAGs, are immunodominant and therefore excellent candidates for development of EPM diagnostics or vaccines. Prior work had identified an EPM isolate lacking the major surface antigen SnSAG1, thus suggesting there may be some diversity in the SnSAGs expressed by different S. neurona isolates. Therefore, a bioinformatic, molecular and immunological study was conducted to assess conservation of the SnSAGs. Examination of an expressed sequence tag (EST) database revealed several notable SnSAG polymorphisms. In particular, the EST information implied that the EPM strain SN4 lacked the major surface antigen SnSAG1. The absence of this surface antigen from the SN4 strain was confirmed by both Western blot and Southern blot. To evaluate SnSAG polymorphisms in the S. neurona population, 14 strains were examined by Western blots using monospecific polyclonal antibodies against the four described SnSAGs. The results of these analyses demonstrated that SnSAG2, SnSAG3, and SnSAG4 are present in all 14 S. neurona strains tested, although some variance in SnSAG4 was observed. Importantly, SnSAG1 was not detected in seven of the strains, which included isolates from four cases of EPM and a case of fatal meningoencephalitis in a sea otter. Genetic analyses by PCR using gene-specific primers confirmed the absence of the SnSAG1 locus in six of these seven strains. Collectively, the data indicated that there is heterogeneity in the surface antigen composition of different S. neurona isolates, which is an important consideration for development of serological tests and prospective vaccines for EPM. Furthermore, the diversity reported herein likely extends to other phenotypes, such as strain virulence, and may have implications for the phylogeny of the various Sarcocystis spp. that undergo sexual stages
Human sensitization to Prosopis Juliflora antigen in Saudi Arabia
International Nuclear Information System (INIS)
Al-Frayh, A.; Gad-el-Rab, Mohammed O.; Al-Mobeireek, K.; Al-Turki, T.; Hasnain, Syed M.; Al-Sedairy, Sultan T.
1999-01-01
Allergenicity Prosopis juliflora pollen antigen has been reported fromonly a few countries, including the US, South Africa, India and Kuwait. Insome parts of Saudi Arabia, species of Prosopis have been introduced by themillions as roadside ornamentation. There appear to be four flowering seasonsduring which pollen grains float in all directions. However, the role ofProsopis pollen as the sensitizing and/or rhinitis in the Kingdom has neverbeen evaluated. A total of 473 allergic patients suffering from the bronchialasthma in four different geographical regions (Abha, Qassim, Hofuf, Gizan),and attending allergy clinics and chest disease centers of university andMinistry of Health hospitals in the region were tested for immediatehypersensitivity reaction to Prosopis Juliflora allergens. Airborne pollengrains at one center were also studied for one full year, using volumetricsampling techniques. A total of 76.1% patients in Qassim, 37.5% in Gizan, 29%in Abha and 11% in Hofuf reacted positively to Prosopis antigen. Multiplesensitivities to other pollen antigens were detected in all patients. Thelevel of airborne Prosopis pollen detected in Gizan exceeded 90 grains m ofair. In view of documented evidence of Prosopis pollen as a sensitizingfactor in Saudi Arabia has been confirmed. However the cause of elicitationof symptoms in many multiple sensitive patients, together with the questionof cross-reactivities, needs thorough and detailed investigation. In vitroconfirmation of all positive results is also required to incriminate Prosopisas one of the major allergens in parts of Saudi Arabia. (author)
Directory of Open Access Journals (Sweden)
Karen R Steingart
2007-06-01
Full Text Available BACKGROUND: The global tuberculosis epidemic results in nearly 2 million deaths and 9 million new cases of the disease a year. The vast majority of tuberculosis patients live in developing countries, where the diagnosis of tuberculosis relies on the identification of acid-fast bacilli on unprocessed sputum smears using conventional light microscopy. Microscopy has high specificity in tuberculosis-endemic countries, but modest sensitivity which varies among laboratories (range 20% to 80%. Moreover, the sensitivity is poor for paucibacillary disease (e.g., pediatric and HIV-associated tuberculosis. Thus, the development of rapid and accurate new diagnostic tools is imperative. Immune-based tests are potentially suitable for use in low-income countries as some test formats can be performed at the point of care without laboratory equipment. Currently, dozens of distinct commercial antibody detection tests are sold in developing countries. The question is "do they work?" METHODS AND FINDINGS: We conducted a systematic review to assess the accuracy of commercial antibody detection tests for the diagnosis of pulmonary tuberculosis. Studies from all countries using culture and/or microscopy smear for confirmation of pulmonary tuberculosis were eligible. Studies with fewer than 50 participants (25 patients and 25 control participants were excluded. In a comprehensive search, we identified 68 studies. The results demonstrate that (1 overall, commercial tests vary widely in performance; (2 sensitivity is higher in smear-positive than smear-negative samples; (3 in studies of smear-positive patients, Anda-TB IgG by enzyme-linked immunosorbent assay shows limited sensitivity (range 63% to 85% and inconsistent specificity (range 73% to 100%; (4 specificity is higher in healthy volunteers than in patients in whom tuberculosis disease is initially suspected and subsequently ruled out; and (5 there are insufficient data to determine the accuracy of most
Vijayaraghavan, Balaje; Xia, Hongyan; Harimoorthy, Rajiv; Liu, Lihong; Belák, Sándor
2012-11-01
Atypical bovine pestiviruses are related antigenically and phylogenetically to bovine viral diarrhea viruses (BVDV-1 and BVDV-2), and may cause the same clinical manifestations in animals. Glycoprotein E(rns) of an atypical bovine pestivirus Th/04_KhonKaen was produced in a baculovirus expression system and was purified by affinity chromatography. The recombinant E(rns) protein was used as an antigen in a microsphere immunoassay for the detection of antibodies against BVDV-1 and atypical bovine pestivirus. The diagnostic performance of the new method was evaluated by testing a total of 596 serum samples, and the assay was compared with enzyme-linked immunosorbent assay (ELISA). Based on the negative/positive cut-off median fluorescence intensity (MFI) value of 2800, the microsphere immunoassay had a sensitivity of 100% and specificity of 100% compared to ELISA. The immunoassay was able to detect antibodies against both BVDV-1 and the atypical pestivirus. This novel microsphere immunoassay has the potential to be multiplexed for simultaneous detection of antibodies against different bovine pathogens in a high-throughput and economical way. Copyright © 2012 Elsevier B.V. All rights reserved.
Wang, Huiqiang; Rong, Qinfeng; Ma, Zhanfang
2016-07-01
Polyhydroquinone-graphene composite as a new redox species was synthesized simply by a microwave-assisted one-pot method through oxidative polymerization of hydroquinone by graphene oxide, which exhibited excellent electrochemical redox activity at 0.124 V and can remarkably promote electron transfer. The as-prepared composite was used as immunosensing substrate in a label-free electrochemical immunosensor for the detection of cytokeratins antigen 21-1, a kind of biomarker of lung cancer. The proposed immunosensor showed wide liner range from 10 pg mL-1 to 200 ng mL-1 with a detection limit 2.3 pg mL-1, and displayed a good stability and selectivity. In addition, this method has been used for the analysis of human serum sample, and the detection results showed good consistence with those of ELISA. The present substrate can be easily extended to other polymer-based nanocomposites.
Zhao, Ting Ting; Peng, Zhe Wei; Yuan, Dan; Zhen, Shu Jun; Huang, Cheng Zhi; Li, Yuan Fang
2018-03-01
In this contribution, we demonstrated that Cu-based metal-organic gel (Cu-MOG) was able to serve as a novel amplification platform for fluorescence anisotropy (FA) assay for the first time, which was confirmed by the sensitive detection of a common cancer biomarker, prostate specific antigen (PSA). The dye-labeled probe aptamer (PA) product was adsorbed onto the benzimidazole derivative-containing Cu-MOG via electrostatic incorporation and strong π-π stacking interactions, which significantly increased the FA value due to the enlargement of the molecular volume of the PA/Cu-MOG complex. With the introduction of target PSA, the FA value was obviously decreased on account of the specific recognition between PSA and PA which resulted in the detachment of PA from the surface of MOG. The linear range was from 0.5-8 ng/mL, with a detection limit of 0.33 ng/mL. Our work has thus helped to demonstrate promising application of MOG material in the fields of biomolecules analysis and disease diagnosis.
Prostate-specific antigen-based prostate cancer screening: Past and future.
Alberts, Arnout R; Schoots, Ivo G; Roobol, Monique J
2015-06-01
Prostate-specific antigen-based prostate cancer screening remains a controversial topic. Up to now, there is worldwide consensus on the statement that the harms of population-based screening, mainly as a result of overdiagnosis (the detection of clinically insignificant tumors that would have never caused any symptoms), outweigh the benefits. However, worldwide opportunistic screening takes place on a wide scale. The European Randomized Study of Screening for Prostate Cancer showed a reduction in prostate cancer mortality through prostate-specific antigen based-screening. These population-based data need to be individualized in order to avoid screening in those who cannot benefit and start screening in those who will. For now, lacking a more optimal screening approach, screening should only be started after the process of shared decision-making. The focus of future research is the reduction of unnecessary testing and overdiagnosis by further research to better biomarkers and the value of the multiparametric magnetic resonance imaging, potentially combined in already existing prostate-specific antigen-based multivariate risk prediction models. © 2015 The Japanese Urological Association.
DEFF Research Database (Denmark)
Fine, J D; Horiguchi, Y; Jester, J
1989-01-01
, esophagus, cervix, and cornea, and BMs surrounding smooth muscle in medium-sized vessels, placenta, uterus, and esophagus. When 16 human fetal skins (aged 54-142 gestational days) were examined, the antigen was first detected at 81 days. Using immunoperoxidase and immunogold staining techniques, indirect......A murine anti-human monoclonal antibody (19-DEJ-1) has been produced that binds to basement membranes (BMs) of the dermoepidermal junction and arrector pili muscles but not to either dermal glandular or vascular BMs. 19-DEJ-1 also recognizes BMs underneath epithelia of buccal mucosa, tongue......-specific proteoglycan that is present within BMs along the epithelial-connective tissue interface and around smooth muscle in skin and other selected organs. Its unique ultrastructural localization suggests the possibility that 19-DEJ-1 may recognize an antigenic epitope of either anchoring filaments or alternatively...
Anti-soluble liver antigen (SLA) antibodies in chronic HCV infection.
Vitozzi, Susana; Lapierre, Pascal; Djilali-Saiah, Idriss; Marceau, Gabriel; Beland, Kathie; Alvarez, Fernando
2004-05-01
Hepatitis C infection is associated with autoimmune disorders, such as the production of autoantibodies. Anti-LKM1 and anti-LC1, immunomarkers of type 2 autoimmune hepatitis, have been previously associated with a HCV infection. Anti-Soluble-Liver-Antigen autoantibodies (SLA) are specifically associated with type 1 and type 2 autoimmune hepatitis and more closely related to patients who relapse after steroid therapy. The recent molecular cloning of the soluble liver antigen provides the opportunity to develop more specific tests for the detection of antibodies against it. The aim of this work is to characterize anti-soluble-liver autoantibodies in sera from patients chronically infected by HCV. A recombinant cDNA from activated Jurkat cells coding for the full length tRNP(Ser)Sec/SLA antigen was obtained. ELISA, Western Blot and immunoprecipitation tests were developed and used to search for linear and conformational epitopes recognized by anti-SLA antibodies in sera from patients chronically infected by HCV. Anti-soluble liver antigen antibodies were found in sera from 10.4% of HCV-infected patients. The prevalence was significantly increased to 27% when anti-LKM1 was also present. Most anti-SLA reactivity was directed against conformational epitopes on the antigen. The means titers by ELISA were lower than those obtained in type 2 AIH. The result of autoantibody isotyping showed a subclass restriction to IgG1 and also IgG4. This study shows the presence of anti-SLA antibodies in approximately 10% of HCV infected patients. The prevalence of SLA autoantibodies in HCV infected patients increases when LKM1 autoantibodies are also present. The relationship between the prevalence of this characteristic autoimmune hepatitis autoantibody and the implication of an autoimmune phenomenon in the liver injury of patients chronically infected by HCV needs further investigation.
Directory of Open Access Journals (Sweden)
Megan Smallwood
Full Text Available Fourth generation (Ag/Ab combination point of care HIV tests like the FDA-approved Determine HIV1/2 Ag/Ab Combo test offer the promise of timely detection of acute HIV infection, relevant in the context of HIV control. However, a synthesis of their performance has not yet been done. In this meta-analysis we not only assessed device performance but also evaluated the role of study quality on diagnostic accuracy.Two independent reviewers searched seven databases, including conferences and bibliographies, and independently extracted data from 17 studies. Study quality was assessed with QUADAS-2. Data on sensitivity and specificity (overall, antigen, and antibody were pooled using a Bayesian hierarchical random effects meta-analysis model. Subgroups were analyzed by blood samples (serum/plasma vs. whole blood and study designs (case-control vs. cross-sectional.The overall specificity of the Determine Combo test was 99.1%, 95% credible interval (CrI [97.3-99.8]. The overall pooled sensitivity for the device was at 88.5%, 95% [80.1-93.4]. When the components of the test were analyzed separately, the pooled specificities were 99.7%, 95% CrI [96.8-100] and 99.6%, 95% CrI [99.0-99.8], for the antigen and antibody components, respectively. Pooled sensitivity of the antibody component was 97.3%, 95% CrI [60.7-99.9], and pooled sensitivity for the antigen component was found to be 12.3%, 95% (CrI [1.1-44.2]. No significant differences were found between subgroups by blood sample or study design. However, it was noted that many studies restricted their study sample to p24 antigen or RNA positive specimens, which may have led to underestimation of overall test performance. Detection bias, selection (spectrum bias, incorporation bias, and verification bias impaired study quality.Although the specificity of all test components was high, antigenic sensitivity will merit from an improvement. Besides the accuracy of the device itself, study quality, also impacts
Kamel, Hanan H; Saad, Ghada A; Sarhan, Rania M
2013-04-01
The purpose of the present study was to evaluate the potential role of the 27-Kilodalton (KDa) antigen versus Fasciola gigantica adult worm regurge antigens in a DOT-Blot assay and to assess this assay as a practical tool for diagnosis fascioliasis in Egyptian patients. Fasciola gigantica antigen of an approximate molecular mass 27-(KDa) was obtained from adult worms by a simple elution SDS-PAGE. A Dot-Blot was developed comparatively to adult worm regurge antigens for the detection of specific antibodies from patients infected with F. gigantica in Egypt. Control sera were obtained from patients with other parasitic infections and healthy volunteers to assess the test and compare between the antigens. The sensitivity, specificity, positive and negative predictive values of Dot-Blot using the adult worm regurge were 80%, 90%, 94.1%, and 69.2% respectively, while those using 27-KDa were 100% which confirms the diagnostic potential of this antigen. All patients infected with Fasciola were positive, with cross reactivity reported with Schistosoma mansoni serum samples. This 27-KDa Dot-Blot assay showed to be a promising test which can be used for serodiagnosis of fascioliasis in Egyptian patients especially, those presenting with hepatic disease. It is specific, sensitive and easy to perform method for the rapid diagnosis particularly when more complex laboratory tests are unavailable.
Chowdhury, M S; al Masum, A; al Karim, E; Semiáo-Santos, S; Rahman, K M; Ar-Rashid, H; el Harith, A
1993-01-01
As part of a large-scale sero-epidemiological survey on visceral leishmaniasis (VL) carried out in Mymensingh district of Bangladesh, applicability of DAT was assessed at the level of a rural health setting in Trishal (upazila) subdistrict. Despite the relatively less optimal conditions encountered, 5854 inhabitants from 7 villages appendant to Trishal were assessed for VL. The demographic distribution for sero-positivity obtained at the rural setting was comparable to that found by DAT as executed at the central laboratory (IEDC&R, Dhaka) on 9619 inhabitants from the same upazila. The overall sero-prevalence rate was 4.4% compared to 3.7% obtained in the population assessed at the central laboratory. In either study, similar VL prevalence rates of 2.1% were obtained in the male populations. Irrespective of sex, younger population ( or = 90 years (1.4% and 1.8%). Local production of DAT antigen employing an authochtonus L. donovani isolate was attempted at the central laboratory (IEDC&R) in Dhaka. By comparison with the reference antigen, titres obtained in all 33 VL sera tested were equally higher (1:6400- > or =: 51200) than in 35 out of 38 negative controls (< or = 1:400-1:1600). A comparable level of reactivity was also obtained in 53 VL and 52 negative control sera using a well characterized L. donovani strain (MHOM/IN/80/D88) from India. However, unlike the reference strain, titres obtained in 7 endemic controls were significantly higher with the authochtonous and homologous antigen (1:3200 - 1:6400) than with the reference (1:100 - 1:1600). The results signify the advantage of employing indigenous L. donovani isolates to further improve DAT sensitivity for detection of early and sub-clinical VL.
International Nuclear Information System (INIS)
Zhang, Z.-G.; Hiromatsu, Y.; Salvi, M.; Triller, H.; Bernard, N.; Wall, J.R.; Medeiros-Neto, G.; Iacona, A.; Lima, N.
1989-01-01
We have studied the prevalence and significance of cytotoxic antibodies against human eye muscle cells, as detected in antibody-dependent cell-mediated cytotoxicity (ADCC) and complement-mediated antibody-dependent cytotoxicity (CMAC) in 51 Cr release assays, in patients with Graves' ophthalmopathy or Hashimoto's thyroiditis. A high prevalence of positive ADCC tests was found in all groups of patients with ophthalmopathy tested. Tests were positive in 64% of patients with Graves' ophthalmopathy from an area of severe iodine deficiency (Sao Paulo) and in 64% of such patients from an iodine replete area (Montreal). In patients with so-called ''euthyroid ophthalmopathy'', i.e. eye disease associated with thyroiditis, ADCC tests were positive in 75 and 38% of patients from the two areas, respectively, while tests were positive in 40 and 22%, respectively, of patients with Graves' hyperthyroidism without evident eye disease. In normal subjects, levels of 51 Cr release was always at background levels. In a group of patients from the high-iodine area, levels of antibodies in ADCC correlated positively with the intraocular pressure (mmHg) in primary position as a parameter of eye muscle dysfunction. In patients with ophthalmopathy, positive ADCC tests were assciated with antibodies to eye muscle membrane antigens of 55,65 and 95 kD as detected by immunoblotting, although the correlation was not close for any antigen. in contrast, CMAC tests were negative in all patients with ophthalmopathy. We also tested 9 mouse and 10 human monoclonal antibodies, reactive with orbital antigens in an enzyme-linked immunosorbent assay, for cytotoxic activity, in ADCC and CMAC, against eye muscle and thyroid cells. All monoclonal antibodies were of the IgM class and negative in ADCC assays. When tested in CMAC against eye muscle cells, one of 9 mouse and 5 of 8 human monoclonal antibodies showed significant activity while tests were positive in one of 9 and one of 10 monoclonal antibodies
Directory of Open Access Journals (Sweden)
Pingping Tang
2018-05-01
Full Text Available Prostate-specific membrane antigen (PSMA is a biomarker for prostate cancer (PCa, and a specific and reliable detection technique of PSMA is urgently required for PCa early diagnosis. A Love wave sensor has been widely studied for real-time sensing and highly sensitive applications, but the sensing unit needs special handling for selective detection purpose. In this study, we prepared a versatile Love wave sensor functionalized with molecularly-imprinted polymers (MIP, PSMA as the template molecule. To enhance the specific template bindings of MIP in pure aqueous solutions, facile reversible addition/fragmentation chain transfer (RAFT precipitation polymerization (RAFTPP was used to produce surface hydrophilic polymer brushes on MIP. The presence of hydrophilic polymer brushes on MIP improved its surface hydrophilicity and significantly reduced their hydrophobic interactions with template molecules in pure aqueous media. In detection process, the acoustic delay-line is confederative to a microfluidic chip and inserted in an oscillation loop. The real-time resonance frequency of the MIP-based Love wave sensor to different concentrations of PSMA was investigated. The limit of detection (LOD for this Love SAW sensor was 0.013 ng mL−1, which demonstrates that this sensor has outstanding performance in terms of the level of detection.
Hanazawa, S; Sagiya, T; Amano, S; Nishikawa, H; Kitano, S
1990-01-01
Recent studies have demonstrated the presence of three serotypes (O1K1, O1K2, and O1K-) of Porphyromonas (Bacteroides) endodontalis. In the present study, a hybridoma cell line producing monoclonal antibody (BEE11) specific for serotype O1K1 of P. endodontalis was established. The specificity of the antibody was evaluated by enzyme-linked immunosorbent assay and immunoslot blot analysis. BEE11 antibody reacted with strains ATCC 35406, HG 400, and HG 421 of the bacterium. However, it did not react with HG 422 or HG 948. Also, the antibody did not react with any of the black-pigmented Bacteroides strains tested. Although the antibody reacted with total cell envelope and capsule materials, it did not do so with lipopolysaccharide. The antibody reacted with antigen material having a molecular mass of 110 kilodaltons (kDa), as judged from fractionation by Superose 12 prep gel chromatography. When the peak fraction from the Superose 12 column was subjected to sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blot (immunoblot) analysis, the reactivity was detected as a single band at an apparent molecular mass of about 52 kDa. The antigen material purified partially by high-performance liquid chromatography was sensitive to trypsin, V8 protease, and heating to 80 degrees C but not to neuraminidase. Therefore, the present study shows that BEE11 antibody recognizes a serotype antigen of P. endodontalis which may be a dimer consisting of monomers having molecular masses of approximately 52 kDa and sensitivity to proteases and heat. Images PMID:2370106
Novel graphene-based biosensor for early detection of Zika virus infection.
Afsahi, Savannah; Lerner, Mitchell B; Goldstein, Jason M; Lee, Joo; Tang, Xiaoling; Bagarozzi, Dennis A; Pan, Deng; Locascio, Lauren; Walker, Amy; Barron, Francie; Goldsmith, Brett R
2018-02-15
We have developed a cost-effective and portable graphene-enabled biosensor to detect Zika virus with a highly specific immobilized monoclonal antibody. Field Effect Biosensing (FEB) with monoclonal antibodies covalently linked to graphene enables real-time, quantitative detection of native Zika viral (ZIKV) antigens. The percent change in capacitance in response to doses of antigen (ZIKV NS1) coincides with levels of clinical significance with detection of antigen in buffer at concentrations as low as 450pM. Potential diagnostic applications were demonstrated by measuring Zika antigen in a simulated human serum. Selectivity was validated using Japanese Encephalitis NS1, a homologous and potentially cross-reactive viral antigen. Further, the graphene platform can simultaneously provide the advanced quantitative data of nonclinical biophysical kinetics tools, making it adaptable to both clinical research and possible diagnostic applications. The speed, sensitivity, and selectivity of this first-of-its-kind graphene-enabled Zika biosensor make it an ideal candidate for development as a medical diagnostic test. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Jayashi, César M; Gonzalez, Armando E; Castillo Neyra, Ricardo; Kyngdon, Craig T; Gauci, Charles G; Lightowlers, Marshall W
2012-12-14
Recombinant antigens cloned from the oncosphere life cycle stage of the cestode parasite Taenia solium (T. solium) have been proven to be effective as vaccines for protecting pigs against infections with T. solium. Previous studies have defined three different host protective oncosphere antigens, TSOL18, TSOL16 and TSOL45. In this study, we evaluated the potential for combining the antigens TSOL16 and TSOL18 as a practical vaccine. Firstly, in a laboratory trial, we compared the immunogenicity of the combined antigens (TSOL16/18) versus the immunogenicity of the antigens separately. Secondly, in a field trial, we tested the ability of the TSOL16/18 vaccine to induce detectable antibody responses in animals living under environmental stress and traditionally reared in areas where T. solium cysticercosis is endemic; and finally, we characterised the immune response of the study population. Pigs of 8-16 weeks of age were vaccinated with 200 μg each of TSOL16 and TSOL18, plus 5mg of Quil-A. Specific total IgG, IgG(1) and IgG(2) antibody responses induced by TSOL16 and TSOL18 were determined with ELISA. The immunogenicity of both antigens was retained in the combined TSOL16/18 vaccine. The combined vaccine TSOL16/18 induced detectable specific anti-TSOL18 antibody responses in 100% (113/113) and specific anti-TSOL16 in 99% (112/113) of the vaccinated animals measured at 2 weeks following the booster vaccination. From the two IgG antibody subtypes analysed we found there was stronger response to IgG(2). Copyright © 2012 Elsevier Ltd. All rights reserved.
Detection of human spermatozoal peptides after conjugation to 125I-labelled human serum albumin
International Nuclear Information System (INIS)
Metler, L.; Skrabei, H.; Czuppon, A.B.
1981-01-01
Human spermatozoal peptides, liberated during autolysis of the cells, were fractionated by gel-filtration chromatography and thin-layer chromatography. After conjugation to 125 I-labelled human serum albumin, all fractions were assayed with rabbit antihuman spermatozoa antiserum. In earlier publications, human sperm-immobilizing and sperm-agglutinating sera were used for the detection of solubilized spermatozoal antigen. The low sensitivity of these tests necessitated a more sensitive test. The purpose of this work is to describe a solid-phase radioimmunoassay for the detection of antigenic peptides
Gioffré, A; Echeverría-Valencia, G; Arese, A; Morsella, C; Garbaccio, S; Delgado, F; Zumárraga, M; Paolicchi, F; Cataldi, A; Romano, M I
2009-12-15
Johne's disease or paratuberculosis is widespread in almost all countries and remains difficult to eradicate. Nowadays, diagnosis of Mycobacterium avium subsp. paratuberculosis (MPTB) infection is one of the main concerns. In this work, we evaluated the expression, biochemical properties and antigenicity of the Apa antigen, encoded by the gene annotated as MAP1569, in the MPTB genome. We confirmed its expression in MPTB and its glycosylation by the ConA binding assay. Although the MPTB-Apa is not an immunodominant antigen, MPTB-infected cattle showed a strong humoral response to recombinant Apa by Western blot and ELISA. Milk was also a suitable sample to be tested by ELISA. We comparatively analysed the humoral cross-reactivity to the Apa from MPTB (MPTB-Apa) and the orthologue from Mycobacterium tuberculosis (MT-Apa, identical to that from Mycobacterium bovis) in both infected and control cows. Response of M. bovis- and MPTB-infected animals against MT-Apa was similar (P=0.6985) but the response of the M. bovis-infected ones to MPTB-Apa was differential, being significantly diminished (PApa stimulation in the IFNgamma release assay, we found no significant differences when compared infected herds with non-infected ones (P=0.34). This antigen, in contrast to bovine Purified Protein Derivative (PPDb), was strongly represented in avian PPD (PPDa), as shown by the recognition of BALB/c mice hyperimmune sera against MPTB-Apa by Dot-blot immunoassay. We therefore demonstrated the antigenicity of Apa in MPTB-infected animals and a differential response to the recombinant antigen when compared to M. bovis-infected animals. These traits herein described, added to the usefulness of milk samples to detect IgG anti-Apa, could be important for routine screening in dairy cattle, considering a multiantigenic approach to overcome the lack of immunodominance.
Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...
Santos, Fred Luciano Neves; Celedon, Paola Alejandra Fiorani; Zanchin, Nilson Ivo Tonin; Leitolis, Amanda; Crestani, Sandra; Foti, Leonardo; de Souza, Wayner Vieira; Gomes, Yara de Miranda; Krieger, Marco Aurélio
2017-10-01
Diagnosing chronic Chagas disease (CD) requires antibody-antigen detection methods, which are traditionally based on enzymatic assay techniques whose performance depend on the type and quality of antigen used. Previously, 4 recombinant chimeric proteins from the Instituto de Biologia Molecular do Paraná (IBMP-8.1 to 8.4) comprising immuno-dominant regions of diverse Trypanosoma cruzi antigens showed excellent diagnostic performance in enzyme-linked immunosorbent assays. Considering that next-generation platforms offer improved CD diagnostic accuracy with different T. cruzi -specific recombinant antigens, we assessed the performance of these chimeras in liquid microarrays (LMAs). The chimeric proteins were expressed in Escherichia coli and purified by chromatography. Sera from 653 chagasic and 680 healthy individuals were used to assess the performance of these chimeras in detecting specific anti- T. cruzi antibodies. Accuracies ranged from 98.1 to 99.3%, and diagnostic odds ratio values were 3,548 for IBMP-8.3, 4,826 for IBMP-8.1, 7,882 for IBMP-8.2, and 25,000 for IBMP-8.4. A separate sera bank (851 samples) was employed to assess cross-reactivity with other tropical diseases. Leishmania , a pathogen with high similarity to T. cruzi , showed cross-reactivity rates ranging from 0 to 2.17%. Inconclusive results were negligible (0 to 0.71%). Bland-Altman and Deming regression analysis based on 200 randomly selected CD-positive and negative samples demonstrated interchangeability with respect to CD diagnostic performance in both singleplex and multiplex assays. Our results suggested that these chimeras can potentially replace antigens currently used in commercially available assay kits. Moreover, the use of multiplex platforms, such as LMA assays employing 2 or more IBMP antigens, would abrogate the need for 2 different testing techniques when diagnosing CD. Copyright © 2017 American Society for Microbiology.
Detection of gonococcal infection : pros and cons of a rapid test.
Vickerman, Peter; Peeling, Rosanna W; Watts, Charlotte; Mabey, David
2005-01-01
WHO estimates that 62 million cases of gonorrhea occur annually worldwide. Untreated infection can cause serious long-term complications, especially in women. In addition, Neisseria gonorrheae infection can facilitate HIV transmission, and babies born to infected mothers are at risk of ocular infection, which can lead to blindness. Where diagnostic facilities are lacking, gonorrhea can be treated syndromically. However, this inevitably leads to over-treatment, especially in women in whom the syndrome of vaginal discharge may be due not to N. gonorrheae infection but to several other more prevalent conditions. Over-treatment is a major concern because of widespread N. gonorrheae antibiotic resistance. Moreover, a high proportion of gonorrhea cases are asymptomatic and so do not present for syndromic management. Such cases will only be detected by screening tests. The gold standard test for the detection of N. gonorrheae is culture, which has high sensitivity and specificity. However, it requires well trained staff and its performance is affected by specimen transport conditions. Other options include microscopy and tests that detect gonococcal antigen or nucleic acid. Nucleic acid amplification tests (NAATs) have higher sensitivity and can be used on non-invasive samples (urine). However, they can cross-react with other Neisseria species and are expensive, requiring highly trained staff and sophisticated equipment. In settings where patients are asked to return for laboratory results, some infected patients never receive treatment as they fail to return for their test results. This reduction in treatment, and the possible onward transmission of N. gonorrheae during any delay in treatment, means that a rapid test of lower sensitivity may be more effective if it results in patients being treated at the initial visit. Indeed, even with the low sensitivity of currently available rapid tests (50-70%), modeling shows that they can outperform gold standard tests in
21 CFR 660.40 - Hepatitis B Surface Antigen.
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Hepatitis B Surface Antigen. 660.40 Section 660.40...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.40 Hepatitis B Surface Antigen. (a) Proper name and definition. The proper name of this product...
Castelain, M; Birnbaum, J; Castelain, P Y; Ducombs, G; Grosshans, E; Jelen, G; Lacroix, M; Meynadier, J; Mougeolle, J M; Lachapelle, J M
1993-11-01
We performed patch tests with Dermatophagoides pteronyssinus (Dp) antigens from 2 different sources in 355 non-randomly selected patients with atopic dermatitis (AD) and 398 subjects of a control group. The study demonstrated that contact sensitization to mites occurred in an appreciable % of AD cases (20.8%), using commonly available assay products. The differences recorded between the 2 materials tested were related to the concentration of P1 antigen. Non-atopic patients rarely showed positive reactions to Dp (0.75%), when strict criteria for readings were applied and if 2 readings were performed. Patients with positive patch tests did not necessarily show positive immediate skin tests. It would be useful to carry out tests systematically in atopic patients, even if it is not yet known what modern treatment would be best for the patient. Laboratories still do not provide standardized house dust mite preparations--measuring and codifying their biological activity--for use in patch tests. It is to be hoped that the extension of this type of test will lead to the production of better test materials, in syringes with homogeneous dispersion and concentration.
Prevalence of Weak D Antigen In Western Indian Population
Directory of Open Access Journals (Sweden)
Tanvi Sadaria
2015-12-01
Full Text Available Introduction: Discovery of Rh antigens in 1939 by Landsteiner and Weiner was the revolutionary stage in blood banking. Of these antigens, D, which decides Rh positivity or negativity, is the most antigenic. A problem is encountered when an individual has a weakened expression of D (Du, i.e., fewer numbers of D antigens on red cell membrane. Aims and Objectives: To know the prevalence of weak D in Indian population because incidence varies in different population. To determine the risk of alloimmunization among Rh D negative patients who receives the blood of weak D positive donors. Material and Methods: Rh grouping of 38,962 donors who came to The Department of Immunohematology and Blood Transfusion of Civil Hospital, Ahmedabad from 1st January 2013 to 30th September 2014 was done using the DIAGAST (Automated Grouping. The samples that tested negative for D antigen were further analysed for weak D (Du by indirect antiglobulin test using blend of Ig G and Ig M Anti D. This was done using Column agglutination method in ID card (gel card. Results: The total number of donors studied was 38,962. Out of these 3360(8.6% were tested Rh D negative. All Rh D negative donors were tested for weak D (Du. 22 (0.056% of total donors and 0.65% of Rh negative donors turned out to be weak D (Du positive. Conclusion: The prevalence of weak D (Du in Western Indian population is 0.056 %, So the risk of alloimmunization in our setting due to weak D (Du antigen is marginal. But, testing of weak D antigen is necessary in blood bank because weak D antigen is immunogenic and can produce alloimmunization if transfused to Rh D negative subjects.
Directory of Open Access Journals (Sweden)
Khairnar Krishna
2007-05-01
Full Text Available Abstract Background Amoebic liver abscess (ALA and pyogenic liver abscesses (PLA appear identical by ultrasound and other imaging techniques. Collection of blood or liver abscess pus for diagnosis of liver abscesses is an invasive procedure, and the procedure requires technical expertise and disposable syringes. Collection of urine is a noninvasive procedure. Therefore, there has been much interest shown towards the use of urine as an alternative clinical specimen for the diagnosis of some parasitic infections. Here, we report for the first time the detection of E. histolytica DNA excreted in the urine for diagnosis of the cases of ALA. Results E. histolytica DNA was detected in liver abscess pus specimen of 80.4% of ALA patients by a nested multiplex polymerase chain reaction (PCR targeting 16S-like r RNA gene. The nested PCR detected E. histolytica DNA in all 37 (100% liver abscess pus specimens collected prior to metronidazole treatment, but were detected in only 53 of 75 (70.6% pus specimens collected after therapy with metronidazole. Similarly, the PCR detected E. histolytica DNA in 21 of 53 (39.6% urine specimens of ALA patients. The test detected E. histolytica DNA in only 4 of 23 (17.4% urine specimens collected prior to metronidazole treatment, but were detected in 17 of 30 (56.7% urine specimens collected after treatment with metronidazole. The enzyme-linked immunosorbent assay (ELISA for the detection of lectin E. histolytica antigen in the liver abscess pus showed a sensitivity of 50% and the indirect haemagglutination (IHA test for detection of amoebic antibodies in the serum showed a sensitivity of 76.8% for the diagnosis of the ALA. Conclusion The present study for the first time shows that the kidney barrier in ALA patients is permeable to E. histolytica DNA molecule resulting in excretion of E. histolytica DNA in urine which can be detected by PCR. The study also shows that the PCR for detection of E. histolytica DNA in urine of
Yadhav Ml, Kala
2014-04-01
Bacterial meningitis is one of the most serious infections seen in infants and children, which is associated with acute complications and chronic morbidity. Infections of Central Nervous System (CNS) still dominate the scene of childhood neurological disorders in most of the developing tropical countries. To isolate, identify and determine the antibiotic susceptibility patterns of pathogens associated with bacterial meningitis. We also aimed to comparatively evaluate of Gram staining, culture and bacterial antigen detection in cerebrospinal fluid samples. Present comparative study included 100 CSF samples of children below the age of 5 years, who were clinically suspected meningitis cases. The samples were subjected to Gram staining, culture and Latex agglutination test (LAT). The organisms isolated in the study were characterized and antibiotic susceptibility test was done according to standard guidelines. It was done by using Gaussian test. Of the 100 cases, 24 were diagnosed as Acute bacterial meningitis (ABM) cases by. Gram staining, culture and latex agglutination test. 21 (87.5%) cases were culture positive, with 2 cases being positive for polymicrobial isolates. Gram staining was positive in 17 (70.53%) cases and LAT was positive in 18 (33.33%) cases. Streptococcus pneumoniae was the predominant organism which was isolated and it was sensitive to antibiotics. In the present study, male to female ratio was 1.27:1, which showed a male preponderance. With the combination of Gram staining, culture, and LAT, 100% sensitivity and specificity can be achieved (p Gram staining and LAT can detect 85% of cases of ABM. Bacterial meningitis is a medical emergency and making an early diagnosis and providing treatment early are life saving and they reduce chronic morbidity.
Solaymani-Mohammadi, Shahram; Rezaian, Mostafa; Babaei, Zahra; Rajabpour, Azam; Meamar, Ahmad R.; Pourbabai, Ahmad A.; Petri, William A.
2006-01-01
The present study was conducted to compare stool antigen detection with PCR for the diagnosis of Entamoeba sp. infection in asymptomatic cyst passers from Iran. Entamoeba dispar and, in one case, E. moshkovskii were the Entamoeba spp. found in the amebic cyst passers. There was a 100% correlation between the results from the TechLab E. histolytica II stool antigen kit and those from nested PCR. We concluded that E. dispar is much more common in asymptomatic cyst passers in Iran and that antig...
Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....
International Nuclear Information System (INIS)
Khan, S. A.; Ahmed, S.; Khan, F. A.; Shamshad, G. U.; Joyia, Z.; Mushahid, N.; Saeed, S.
2013-01-01
Objective: To determine the sensitivity of a real time polymerase chain reaction (PCR) for malaria diagnosis and to compare its accuracy with microscopy and an antigen based rapid diagnostic test (OptiMal). Study Design: Cross-sectional analytical study. Place and Duration of Study: Military Hospital, Armed Forces Institute of Transfusion and Armed Forces Institute of Pathology, Rawalpindi, from July to December 2011. Methodology: Venous blood samples of 300 clinically suspected patients of malaria were tested for malaria parasite by microscopy and OptiMal; and malaria parasite index was calculated for the positive samples. Plasmodium genus specific real time PCR was performed on all specimens, targeting small subunit rRNA gene. Diagnostic accuracy of three tests was compared and cost analysis was done. Results: Out of 300 patients, malaria parasite was detected in 110, 106 and 123 patients by microscopy, OptiMAL and PCR respectively. Real time PCR was 100% sensitive while microscopy and OptiMal had sensitivity of 89.4% and 86.2% respectively. All methods were 100% specific. The cost per test was calculated to be 0.2, 2.75 and 3.30 US dollar by microscopy, OptiMal and PCR respectively, excluding the once capital cost on PCR equipment. Conclusion: Genus specific real time PCR for the diagnosis of malaria was successfully established as a highly sensitive and affordable technology that should be incorporated in the diagnostic algorithm in this country. (author)
International Nuclear Information System (INIS)
Atti, Miska Elyemen; TR, Unnasch; Mukhtar, M.M.
1999-01-01
Onchcerciasis is endemic in three geographical regions in Sudan, and presented with variable clinical reactions. The current diagnosis of onchocerciasis is based on detection of live microflaraie in skin snips in addition to clinical signs and history of living in endemic regions. Different serological diagnostic trials using crude soluble antigens of O. volvulus have shown variable degrees of cross reaction with other nematodes co-endemic in the same area. We have studied the sensitivity and specificity of RAL-2, calreticulin and PDI O. volvulus cloned antigens using the ELISA techniques. Eighty serum samples of Onchocerciasis patients, 20 non endemic normal controls and 42 samples of patients of other endemic deseas including Leishmanoasis, malaria, tuberculosis and shestosomiasis were tested RAL-2 gave the best Ig G response, with 83.75% sensitivity and 91. 66% specificity. PDI sensitivity was 20% and specificity 91.66%, while calreticulum showed sensitivity of 37.5% and specificity of 73.30%. IgG3 subclasses was not significantly different from controls while IgG4 was significantly higher in patients. The sensitivity of RAL-2 for IgG4 was 90% with a specificity of 100%. For PDI sensitivity was 25% and 100% specificity while calreticulin resulted in sensitivity of 75% and specificity of 100%. Low levels of circulating IgE to RAL-2 antigen were detected. For all antigens there was significant correlation with gender, age, microflarial load or presence of nodules. (Author)
International Nuclear Information System (INIS)
Weiner, M.H.; Coats-Stephen, M.
1979-01-01
Because systemic aspergillosis is difficult to diagnose ante mortem, a study to improve immunodiagnosis was undertaken in a rabbit model of disseminated infection. We found that the predominant humoral response of infected animals was directed against four Aspergillus antigens identified by crossed immunoelectrophoresis. One of these antigens, a cell-wall carbohydrate, was purified by gel-filtration chromatography and was used to develop a radiommunoassay. The sensitivity of this assay was increased by testing for serum-bound antigen as well as for free antigen. When the sensitivity of the RIA was evaluated in the animal model, antigenemia was detected in 78% of 51 rabbits with disseminated infection and ante mortem in 86% of 42 rabbits with lethal infection. By contrast, with immunoprecipitin analysis only eight of 51 rabbits were positive for antigen, and six of 51 rabbits were positive for Aspergillus antibody. The specificity of the RIA was also tested. Negative controls for antigen included sera from 76 normal rabbits and sera from 25 rabbits with systemic candidiasis. The Candida control group is pertinent because 48% of these rabbits had specific Candida antigenemia detected by a mannan RIA. This study demonstrates that Aspergillus antigenemia occurs during the course of experimental disseminated aspergillosis and illustrates the potential of an Aspergillus antigen RIA for sensitive, specific immunodiagnosis of human infections
Utility of PCR, Culture, and Antigen Detection Methods for Diagnosis of Legionellosis.
Chen, Derrick J; Procop, Gary W; Vogel, Sherilynn; Yen-Lieberman, Belinda; Richter, Sandra S
2015-11-01
The goal of this retrospective study was to evaluate the performance of different diagnostic tests for Legionnaires' disease in a clinical setting where Legionella pneumophila PCR had been introduced. Electronic medical records at the Cleveland Clinic were searched for Legionella urinary antigen (UAG), culture, and PCR tests ordered from March 2010 through December 2013. For cases where two or more test methods were performed and at least one was positive, the medical record was reviewed for relevant clinical and epidemiologic factors. Excluding repeat testing on a given patient, 19,912 tests were ordered (12,569 UAG, 3,747 cultures, and 3,596 PCR) with 378 positive results. The positivity rate for each method was 0.4% for culture, 0.8% for PCR, and 2.7% for UAG. For 37 patients, at least two test methods were performed with at least one positive result: 10 (27%) cases were positive by all three methods, 16 (43%) were positive by two methods, and 11 (30%) were positive by one method only. For the 32 patients with medical records available, clinical presentation was consistent with proven or probable Legionella infection in 84% of the cases. For those cases, the sensitivities of culture, PCR, and UAG were 50%, 92%, and 96%, respectively. The specificities were 100% for culture and 99.9% for PCR and UAG. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
DEFF Research Database (Denmark)
Mukai, Thomas; Bro, Flemming; Pedersen, Knud Venborg
Background: Prostate Cancer (PC) is the most common type of cancer among Danish men, and the incidence is increasing. PC is often asymptomatic, making it difficult to establish a clinical diagnosis. The general practitioner can use prostate-specific antigen (PSA) testing as a tool for diagnosing PC...
Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah
2018-01-01
Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
Directory of Open Access Journals (Sweden)
Solomon Dhliwayo
2016-10-01
Full Text Available A study was carried out to determine the prevalence of blood group antigen dog erythrocyte antigen (DEA 1.1 in mixed breed dogs in rural Chinamhora, Zimbabwe. DEA 1.1 is clinically the most important canine blood group as it is the most antigenic blood type; hence, DEA 1.1 antibodies are capable of causing acute haemolytic, potentially life-threatening transfusion reactions. In this study, blood samples were collected from 100 dogs in Chinamhora, and blood typing was carried out using standardised DEA 1.1 typing strips with monoclonal anti–DEA 1.1 antibodies (Alvedia® LAB DEA 1.1 test kits. Polymerase chain reaction for detecting Babesia spp. antigen was carried out on 58 of the samples. Of the 100 dogs, 78% were DEA 1.1 positive and 22% were DEA 1.1 negative. A significantly (p = 0.02 higher proportion of females (90.5% were DEA 1.1 positive than males (69.0%. The probability of sensitisation of recipient dogs following first-time transfusion of untyped or unmatched blood was 17.2%, and an approximately 3% (2.95% probability of an acute haemolytic reaction following a second incompatible transfusion was found. Babesia spp. antigen was found in 6.9% of the samples. No significant relationship (χ2 = 0.56, p = 0.45 was found between DEA 1.1 positivity and Babesia spp. antigen presence. Despite a low probability of haemolysis after a second incompatibility transfusion, the risk remains present and should not be ignored. Hence, where possible, blood typing for DEA 1.1 is recommended. A survey of DEA 3, 4, 5 and 7 in various breeds is also recommended.
Comparison of three laboratorial tests for diagnosis of canine parvovirus infection
Directory of Open Access Journals (Sweden)
M.M.O. Silva
2013-02-01
Full Text Available The aim of this study was to evaluate the rapid tests currently used for canine parvovirus (CPV diagnosis: hemagglutination test (HA, enzyme immunoassay (EIA and polymerase chain reaction (PCR. A total of 112 fecal samples collected from diarrheic puppies up to one year of age were tested. The EIA was able to detect CPV antigen in 44 samples. By HA, 32 samples tested highly positive with titers >128, eight tested weakly positive (titers 32 and 64 and 72 were negative (titers <16. Using PCR, 57 samples were found positive including 13 EIA-negative and 19 HA-negative samples. The best correlation was observed between EIA and PCR (88.4%. These tests were able to detect all types of CPV, including CPV-2c. Considering that 23%-33% of dogs presenting enteritis did not show infection by EIA nor HA, negative results from the antigen detection tests should be confirmed through molecular methods.
Directory of Open Access Journals (Sweden)
Kuiyu Zhu
2015-08-01
Full Text Available Primary hepatic carcinoma (PHC is one of the most common malignancies worldwide, resulting in death within six to 20 months. The survival rate can be improved by effective treatments when diagnosed at an early stage. The α-fetoprotein (AFP and carcinoembryonic antigen (CEA have been identified as markers that are expressed at higher levels in PHC patients. In this study, we employed silicon nanowire field-effect transistors (SiNW-FETs with polydimethylsiloxane (PDMS microfluidic channels to simultaneously detect AFP and CEA in desalted human serum. Dual-channel PDMS was first utilized for the selective modification of AFP and CEA antibodies on SiNWs, while single-channel PDMS offers faster and more sensitive detection of AFP and CEA in serum. During the SiNW modification process, 0.1% BSA was utilized to minimize nonspecific protein binding from serum. The linear dynamic ranges for the AFP and CEA detection were measured to be 500 fg/mL to 50 ng/mL and 50 fg/mL to 10 ng/mL, respectively. Our work demonstrates the promising potential of fabricated SiNW-FETs as a direct detection kit for multiple tumor markers in serum; therefore, it provides a chance for early stage diagnose and, hence, more effective treatments for PHC patients.
Designed ankyrin repeat proteins: a new approach to mimic complex antigens for diagnostic purposes?
Directory of Open Access Journals (Sweden)
Stefanie Hausammann
Full Text Available Inhibitory antibodies directed against coagulation factor VIII (FVIII can be found in patients with acquired and congenital hemophilia A. Such FVIII-inhibiting antibodies are routinely detected by the functional Bethesda Assay. However, this assay has a low sensitivity and shows a high inter-laboratory variability. Another method to detect antibodies recognizing FVIII is ELISA, but this test does not allow the distinction between inhibitory and non-inhibitory antibodies. Therefore, we aimed at replacing the intricate antigen FVIII by Designed Ankyrin Repeat Proteins (DARPins mimicking the epitopes of FVIII inhibitors. As a model we used the well-described inhibitory human monoclonal anti-FVIII antibody, Bo2C11, for the selection on DARPin libraries. Two DARPins were selected binding to the antigen-binding site of Bo2C11, which mimic thus a functional epitope on FVIII. These DARPins inhibited the binding of the antibody to its antigen and restored FVIII activity as determined in the Bethesda assay. Furthermore, the specific DARPins were able to recognize the target antibody in human plasma and could therefore be used to test for the presence of Bo2C11-like antibodies in a large set of hemophilia A patients. These data suggest, that our approach might be used to isolate epitopes from different sets of anti-FVIII antibodies in order to develop an ELISA-based screening assay allowing the distinction of inhibitory and non-inhibitory anti-FVIII antibodies according to their antibody signatures.
Dorny, P; Dermauw, V; Van Hul, A; Trevisan, C; Gabriël, S
2017-10-15
Taenia solium taeniasis/cysticercosis is a zoonosis included in the WHO's list of neglected tropical diseases. Accurate diagnostic tools for humans and pigs are needed to monitor intervention outcomes. Currently used diagnostic tools for porcine cysticercosis all have drawbacks. Serological tests are mainly confronted with problems of specificity. More specifically, circulating antigen detecting tests cross-react with Taenia hydatigena and the possibility of transient antigens as a result of aborted infections is suspected. Furthermore, the hypothesis has been raised that hatched ingested eggs of other Taenia species may lead to a transient antibody response or to the presence of circulating antigen detectable by serological tests used for porcine cysticercosis. Here we describe the results of a study that consisted of oral administration of Taenia saginata eggs to five piglets followed by serological testing during five weeks and necropsy aiming at studying possible cross reactions in serological tests used for porcine cysticercosis. The infectivity of the eggs was verified by in vitro hatching and by experimental infection of a calf. One piglet developed acute respiratory disease and died on day 6 post infection. The remaining four piglets did not show any clinical signs until euthanasia. None of the serum samples from four piglets collected between days 0 and 35 post infection gave a positive reaction in the B158/B60 Ag-ELISA and in a commercial Western blot for antibody detection. In conclusion, this study showed that experimental exposure of four pigs to T. saginata eggs did not result in positive serologies for T. solium. These results may help interpreting serological results in monitoring of T. solium control programmes. Copyright © 2017 Elsevier B.V. All rights reserved.
Sun, Juan; Chang, Yan-Xiang; Niu, Chun-Yan
2017-11-01
The overexpression of soluble human leukocyte antigen-G is associated with malignant tumours. The purpose of our study was to detect soluble human leukocyte antigen-G concentrations in ascites and to evaluate the value of ascitic soluble human leukocyte antigen-G for the diagnosis of malignant ascites. Enzyme-linked immunosorbent assay was used to detect soluble human leukocyte antigen-G levels in 64 patients with malignant ascites and 30 patients with benign ascites. Receiver operating characteristic curves were used to evaluate the diagnostic efficacy of ascitic soluble human leukocyte antigen-G for the detection of malignant ascites. Ascitic soluble human leukocyte antigen-G levels were significantly higher in the malignant ascites group than in the benign ascites group (20.718 ± 3.215 versus 12.467 ± 3.678 µg/L, t = 7.425, p human leukocyte antigen-G was 0.957 (95% confidence interval, 0.872-0.992). At a cut-off value of 19.60 µg/L, the sensitivity and specificity of ascitic soluble human leukocyte antigen-G were 87.5% (95% confidence interval, 71.0%-96.5%) and 100% (95% confidence interval, 88.4%-100%), respectively. With respect to area under the receiver operating characteristic curve, sensitivity and specificity, ascitic carcinoembryonic antigen (0.810, 68.75% and 83.33%, respectively) and carbohydrate antigen 19-9 (0.710, 65.63% and 70%, respectively) significantly differed (all p human leukocyte antigen-G was 75%, which was higher than the corresponding rates for ascitic carcinoembryonic antigen (31.25%) and carbohydrate antigen 19-9 (6.25%; both p human leukocyte antigen-G exhibited good performance for diagnosing malignant ascites, and particularly those that were cytology-negative and biopsy-positive.
Rastawicki, Waldemar; Kałużewski, Stanisław
2015-01-01
The laboratory diagnosis of typhoid fever is dependent upon either isolation of S. Typhi from a clinical sample or the detection of raised titers of serum antibodies in the Widal test or the passive hemagglutination assay (PHA). In this study we evaluated the usefulness of ELISA for detection of antibodies to S. Typhi lipopolysaccharide O and capsular polysaccharide Vi antigens in the sera of persons from outbreak of typhoid fever. Fifteen serum samples from patients with laboratory confirmed typhoid fever and 140 sera from persons suspected for contact with typhoid fever patients from outbreak in 1974/75 in Poland were tested by ELISA. Additionally, as the control group, we tested 115 sera from blood donors for the presence of S. Typhi anti-LPS and anti-Vi antibodies. Anti-LPS and anti-Vi antibodies were detected in 80% and 53.3% of sera obtained from patients with laboratory confirmed typhoid fever, respectively. The high percentages of positive results in ELISA were also noted in the group of persons suspected for contact with typhoid fever patients (51.4% and 45%) but not in the group of blood donors (7.8% and 6.1%, respectively). The ELISA could be a useful tool for the serological diagnosis of typhoid fever in patients who have clinical symptoms but are culture negative, especially during massive outbreaks of typhoid fever.
Directory of Open Access Journals (Sweden)
Jingjing Mao
Full Text Available Rabbit hepatitis E virus (HEV is a novel genotype of HEV, and is considered to pose a risk of zoonotic transmission. Research into the systemic distribution of rabbit HEV in rabbits during different periods of infection has rarely been reported. To better understand this virus, we infected rabbits with second-passage rabbit HEV via an intraperitoneal route. After inoculation, the infection showed two types, temporary and constant infection. The detection of HEV RNA in the feces varied with time, and serum antigen correlated with fecal HEV RNA. Viremia only appeared 72 days after inoculation. The rabbits remained antibody negative throughout the experimental period. When HEV was localized, several organs besides the liver were HEV RNA positive. Tissue antigen was observed immunohistochemically in the different cells of various organs, especially in parts of the small intestine and the characteristic rabbit gut-associated lymphoid tissue. These data provide valuable information for future research into the pathogenesis of HEV.
Utility of HLA Antibody Testing in Kidney Transplantation
Konvalinka, Ana
2015-01-01
HLA antigens are polymorphic proteins expressed on donor kidney allograft endothelium and are critical targets for recipient immune recognition. HLA antibodies are risk factors for acute and chronic rejection and allograft loss. Solid-phase immunoassays for HLA antibody detection represent a major advance in sensitivity and specificity over cell-based methods and are widely used in organ allocation and pretransplant risk assessment. Post-transplant, development of de novo donor–specific HLA antibodies and/or increase in donor-specific antibodies from pretransplant levels are associated with adverse outcomes. Although single antigen bead assays have allowed sensitive detection of recipient HLA antibodies and their specificities, a number of interpretive considerations must be appreciated to understand test results in clinical and research contexts. This review, which is especially relevant for clinicians caring for transplant patients, discusses the technical aspects of single antigen bead assays, emphasizes their quantitative limitations, and explores the utility of HLA antibody testing in identifying and managing important pre- and post-transplant clinical outcomes. PMID:25804279
Li, Jia-dong; Cheng, Jun-jie; Miao, Bin; Wei, Xiao-wei; Xie, Jie; Zhang, Jin-cheng; Zhang, Zhi-qiang; Wu, Dong-min
2014-07-01
In order to improve the sensitivity of AlGaN/GaN high electron mobility transistor (HEMT) biosensors, a simple biomolecule-gated AlGaN/GaN HEMT structure was designed and successfully fabricated for prostate specific antigen (PSA) detection. UV/ozone was used to oxidize the GaN surface and then a 3-aminopropyl trimethoxysilane (APTES) self-assembled monolayer was bound to the sensing region. This monolayer serves as a binding layer for attachment of the prostate specific antibody (anti-PSA). The biomolecule-gated AlGaN/GaN HEMT sensor shows a rapid and sensitive response when the target prostate-specific antigen in buffer solution was added to the antibody-immobilized sensing area. The current change showed a logarithm relationship against the PSA concentration from 0.1 pg/ml to 0.993 ng/ml. The sensitivity of 0.215% is determined for 0.1 pg/ml PSA solution. The above experimental result of the biomolecule-gated AlGaN/GaN HEMT biosensor suggested that this biosensor might be a useful tool for prostate cancer screening.
International Nuclear Information System (INIS)
Li, Jia-dong; Miao, Bin; Wei, Xiao-wei; Xie, Jie; Wu, Dong-min; Cheng, Jun-jie; Zhang, Jin-cheng; Zhang, Zhi-qiang
2014-01-01
In order to improve the sensitivity of AlGaN/GaN high electron mobility transistor (HEMT) biosensors, a simple biomolecule-gated AlGaN/GaN HEMT structure was designed and successfully fabricated for prostate specific antigen (PSA) detection. UV/ozone was used to oxidize the GaN surface and then a 3-aminopropyl trimethoxysilane (APTES) self-assembled monolayer was bound to the sensing region. This monolayer serves as a binding layer for attachment of the prostate specific antibody (anti-PSA). The biomolecule-gated AlGaN/GaN HEMT sensor shows a rapid and sensitive response when the target prostate-specific antigen in buffer solution was added to the antibody-immobilized sensing area. The current change showed a logarithm relationship against the PSA concentration from 0.1 pg/ml to 0.993 ng/ml. The sensitivity of 0.215% is determined for 0.1 pg/ml PSA solution. The above experimental result of the biomolecule-gated AlGaN/GaN HEMT biosensor suggested that this biosensor might be a useful tool for prostate cancer screening. (paper)
Directory of Open Access Journals (Sweden)
L. V. Slogotskaya
2015-01-01
Full Text Available Explanation. Mantoux test is used to detect the tuberculous infection; however, low specificity of this method results in a high rate of false positive responses due to cross-reactions of PPD (protein purified derivate antigens contained in many mycobacterial species and Bacillus Calmette-Guerin (BCG strains. New drug Diaskintest (DST — recombinant protein CFP10-ESAT6 produced by Escherichia coli BL21(DE3/pCFP-ESAT proved to be the best acceptable diagnostic drug. The article was aimed at studying effectiveness of tuberculous recombinant allergen tests for detecting tuberculosis in the children and adolescents, who were registered in Moscow in 2013. Methods. Mantoux tests were used to examine 1,420,100 persons; positive reactions were observed in 1,020,000 children and adolescents (71,8%; 131,361 (12.9% of them were examined using DSTs. Results. Positive reactions to DST were observed in 3,304 persons (2.5% of the persons with positive reactions to Mantoux test. The tuberculosis detection rate among the persons with positive reactions to Mantoux tests using 2TU PPD-L (Leningrad Research Institute of Vaccines and Serums is 0.13%, among the persons with positive reactions to DSTs — 4.9%, i.e. 40 times more often (p = 0.000. Post-tuberculosis alterations were detected in 169 persons: in 0.13% of the persons with positive reactions to Mantoux tests using 2TU PPD-L and in 5.1% of the persons with positive reactions to DSTs (p = 0.000. Conclusion. Cohort studies conducted in Moscow demonstrated high effectiveness of Diaskintests for detecting tuberculosis in children and adolescents. High sensitivity of the method helps to detect the overwhelming majority of the persons with tuberculosis.
Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening.
Li, Jun; Zhao, Guixiang; Hall, Ingrid J
2015-08-01
For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (ptesting with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients' values and preferences in decisions about PSA testing. Published by Elsevier Inc.
Detection of autoimmune antibodies in localized scleroderma by synthetic oligonucleotide antigens
DEFF Research Database (Denmark)
Samuelsen, Simone; Jørgensen, Christian Damsgaard; Mellins, Elizabeth D
2018-01-01
In this study, we developed a series of synthetic oligonucleotides that allowed us to investigate the details on the antigen recognition by autoimmune antibodies in localized scleroderma subjects. Besides dramatically improved analytical specificity of the assay, our data suggests a potential...... linking for antibodies to DNA to the biological status of disease state in localized scleroderma. Moreover, introducing chemical modifications into short synthetic deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) molecules completely changed the binding titers of corresponding antibodies...... and their clinical relevance. The strongest observed effect was registered for the localized scleroderma skin damage index (LoSDI) on the IgG antibodies to TC dinucleotide-rich double-stranded antigen (p
Directory of Open Access Journals (Sweden)
Tuan Nur Akmalina Mat Jusoh
2017-01-01
Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.
Directory of Open Access Journals (Sweden)
Rodríguez Islay
2002-01-01
Full Text Available A recombinant-antigen enzyme immunoassay (EIA, BioSCREEN TM anti-Treponema pallidum, was compared favorably with the T. pallidum hemagglutination test, in the detection of specific antibodies in different groups of sera from patients with primary (n = 38, secondary (n = 10, early latent (n = 28 and congenital syphilis (n = 2, patients with leptospirosis ( n= 8, infectious mononucleosis (n = 7, hepatitis (n = 9, diabetes mellitus (n = 11, rheumatoid arthritis (n = 13, leprosy (n = 11, tuberculosis (n = 9, HIV/Aids ( n= 12, systemic lupus erythematosus (n = 4, rheumatic fever (n = 3, old-persons (n = 9, pregnant women (n = 29 and blood donors (n = 164. The coincidence between them was 95.1%. The sensitivity and specificity of the EIA were 93.3% and 95.5%, respectively. Fifteen serum specimens belonging to old-persons, pregnant women, blood donors, and patients with human leptospirosis, hepatitis, diabetes mellitus, tuberculosis and rheumatic fever gave false-positive results by Venereal Disease Research Laboratory and/or Rapid Plasma Reagin. The EIA can be used as alternative method for the serological confirmation of syphilis.
Arias, M; Hillyer, G V; Sánchez-Andrade, R; Suárez, J L; Pedreira, J; Lomba, C; Díaz, P; Morrondo, P; Díez-Baños, P; Paz-Silva, A
2006-04-15
The suitability of an enzyme linked immunosorbent assay (ELISA) test with a 2.9 kDa Fasciola hepatica-recombinant protein (FhrAPS) for diagnosing early and current-ovine fasciolosis was analyzed, and compared to that obtained by using a direct ELISA for detecting F. hepatica-circulating FhES antigens and to the coprological sedimentation for fluke egg quantitation. Fourteen Gallega autochthonous breed sheep were experimentally infected with metacercariae by a trickle system (small repetitive infections) and divided into two groups: G-I represented a primary infection for 34 weeks; G-R, animals with primary infection and reinfected 18 w.a.p.i. Seven sheep were left uninfected as the control group (G-C). Serum IgG antibody values against the FhrAPS rose rapidly by 1st w.a.p.i. in all infected sheep. Antibody levels in those with primary infection (G-I, G-C) peaked at 10 weeks, diminishing slightly and levelling from 16 to 34 weeks. Those with primary infection reinfected at 18 weeks had a rebound effect with the highest values observed. Circulating F. hepatica-ES antigens were detected by the 1st w.a.p.i. in all infected groups peaking at 6 weeks, decreasing rapidly to uninfected control values by 10 weeks of infection. Faecal egg-output started 11 weeks after primary infection. An increase in the IgG antibody as well as antigen responses to the FhrAPS and to anti-FhES from the 18 w.a.p.i. was recorded in G-T and G-R after the challenge infection. Antibody levels remained high whereas antigenemia values diminished after 6 weeks. A positive significant correlation between the IgG response against the FhrAPS and the F. hepatica circulating antigens (r2 = 0.428, p = 0.001) was obtained. In conclusion, our standardized diagnostic ELISA for fasciolosis based on the detection of IgG responses to the FhrAPS would be a valuable tool to diagnosis early and current F. hepatica-infections in sheep.
International Nuclear Information System (INIS)
Casali, P.; Bossus, A.; Carpentier, N.A.; Lambert, P.H.
1977-01-01
Bovine conglutinin was used in a solid-phase assay for the detection of immune complexes. In a first step, the tested serum sample was incubated in polypropylene tubes coated with conglutinin to allow C3-coated immune complexes to bind to solid-phase conglutinin. In a second step, the conglutinin-bound complexes were detected using an enzyme-conjugated or radiolabelled anti-immunoglobulin antibody. The conglutinin-binding (KgB) test did not suffer from the interference of DNA, heparin or endotoxins. Its limit of sensitivity for aggregated IgG was 3 μg/ml undiluted human serum. Immune complexes prepared in vitro using tetanus toxoid, or DNA, and corresponding antibodies in human sera could be detected at various antigen/antibody ratios and at antibody concentrations lower than 8 μg/ml. The KgB test allowed for the detection of immune complexes in sera from patients with systemic lupus erythematosus, rheumatoid arthritis, idiopathic vasculitis, leprosy and leukemia. These sera were also tested using the 125 I-labelled Clq-binding activity (BA) test and the KgB test simultaneously, and a significant rank order correlation was observed. In patients with leukemia, a significant correlation was observed using three tests, KgB, 125 I-labelled Clq BA and Raji-cell radioimmunoassay (RIA). Therefore, the KgB test appears as a simple and reproducible method, utilizing a very stable reagent, with a sensitivity and specificity comparable to the other tests studied and allowing for clinical application. (author)
Selection of tests for outlier detection
Bossers, H.C.M.; Hurink, Johann L.; Smit, Gerardus Johannes Maria
Integrated circuits are tested thoroughly in order to meet the high demands on quality. As an additional step, outlier detection is used to detect potential unreliable chips such that quality can be improved further. However, it is often unclear to which tests outlier detection should be applied and
The fluorescent treponemal antibody-absorption (FTA-ABS) test for syphilis.
Hunter, E F
1975-01-01
The FTA test was developed at a time when immunofluorescence procedures were not well-defined. Through technique control and research, a modification of the FTA test, the FTA-ABS, has attained a position as one of the leading treponemal tests to confirm the reagin tests for syphilis. In this review of the FTA-ABS test, attention has been focused on reagent development, with the anticipation that reagent standardization may soon become a reality. The T. pallidum antigen obtained by extracting infected rabbit testicular tissue has evolved from a preparation in which the treponemes remained in the initial extracting fluid to a reagent that can be free of rabbit tissue and globulin. These washed antigen preparations improve visibility of the treponemes on the microscope slide, reduce background fluorescence, and reduce or prevent from occurring nonspecific reactions that are a result of tissue and globulin components. Both washed and nonwashed antigens are available commercially, and, to date, little differentiation has appeared on the product label. The predominant immunoglobulin that reacts with T. pallidum in the indirect fluorescent antibody tests appears to be IgG. This is the major immunoglobulin detected in the FTA-ABS test. IgM, although increased in early syphilis, is also increased in other clinical conditions. Several reports suggest that adult IgM detection in the present FTA-ABS test would be nonspecific. Until specific IgM antibody in adult syphilis can be detected without a risk to test specificity, the conjugate for the FTA-ABS test should continue to be an anti-IgG reagent. Class-specific, anti-IgG reagents are more expensive than other reagents; however, their use may eliminate the problem of nonspecificity resulting from IgM detection. Additionally, micromethods can be used to reduce cost, and this possibility should be investigated. The sorbent that contains an antigen to the Reiter treponeme may or may not specifically absorb the reactivity that
Energy Technology Data Exchange (ETDEWEB)
Avraham, H.; Golenser, J.; Gazitt, Y.; Spira, D.T.; Sulitzeanu, D. (Hebrew Univ., Jerusalem (Israel). Hadassah Medical School)
1982-08-27
A highly sensitive radioimmunoassay for detection of P. falciparum antibodies and antigens is described. A partially purified P. falciparum antigen preparation is obtained from in vitro cultured parasites enriched after gelatin sedimentation by sonicating the infected red blood cells and precipitating the proteins with 50% saturated ammonium sulfate. The precipitate is dissolved in buffer, ultracentrifuged and used to coat wells of microtiter plates. Anti-P. falciparum antibodies are detected by incubating antiserum dilutions in the coated wells and detecting the bound IgG with radioiodinated staphylococcal protein A. P. falciparum antigens are detected by their ability to inhibit binding of antibodies to the coated wells. Sera of individuals with a history of P. falciparum infection contain antibodies detectable at a dilution of 1:75,000. P. falciparum RBC infected in vitro can be detected at levels of parasitemia of the order of 1 parasite or less per 10/sup 6/ RBC.
Wang, Chunying; Hou, Fei; Ma, Yicai
2015-06-15
A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 μL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. Copyright © 2014 Elsevier B.V. All rights reserved.
The characteristics exosporium antigens from different vaccine strains of bacillus antracis
International Nuclear Information System (INIS)
Baranova, E.; Biketov, S.; Dunaytsev, I.; Mironova, R.; Dyatlov, I.
2009-01-01
To develop of both test-systems for rapid detection and identification of B. anthracis spores and a new subunit vaccine the antigens on the spore surface should be characterized. Exosporium consists of two layers-basal and peripheral and has been form by protein, amino- and neutral polysaccharides, lipids and ash. Number of anthrax exosporium proteins was described and identified: glycoprotein BclA, BclB, alanine racemase, inosine hydrolase, glycosyl hydrolase, superoxid dismutase, ExsF, ExsY, ExsK,CotB,CotY and SoaA. So far no glycosylated proteins other then highly immunogenic glycoproteins BclA, BclB were detected in the B. anthracis spore extract although several exosporium-specific glycoprotein have been described in other members of the B.cereus family- B. thuringiensis and B. cereus. Although EA1 protein originally described as main component of S-layer from vegetative cells he can regular observed in different exosporium preparations and additionally some anti- EA1 monoclonal antibodies able to recognize spore surface. We have revealed that EA1 isolated from spore of Russians strain STI-1contain carbohydrate which determine immunogenicity of this antigen. Because some time ago we have found that exosporium protein's pattern variable among B. anthracis strains we investigated exosporium from spore of different strains of B. anthracis including STI-1, Ames, Stern and others. We have comparative characterized antigens by using Western Blotting, Two-Dimensional electrophoresis and Mass Spec analysis. The results of analysis will be presented and discussed.(author)
Directory of Open Access Journals (Sweden)
Daniel O. Griffin
Full Text Available Despite much focus on moving toward a cure to end the epidemic human immunodeficiency virus (HIV epidemic there are still thousands of new infections occurring every year in the United States. Although there is ongoing transmission of HIV in the United States and a growing population of people living with HIV, the acute presentation of HIV infection can be challenging to diagnose and is often not considered when patients present to healthcare providers. Although in certain states there are HIV testing laws that require that all persons between the ages of 13 and 64 be offered HIV testing in an opt-out approach, many patient presenting with an acute illness, that would warrant diagnostic testing for HIV, leave without having an HIV test performed for either diagnostic or screening purposes.We describe the case of a woman who presented to medical attention with symptoms later confirmed to be due to acute HIV infection. She was initially discharged from the hospital and only underwent HIV testing with confirmation of her diagnosis after readmission. We describe the algorithm where fourth generation testing combined with HIV viral load testing allowed for the diagnosis of acute HIV prior to the development of a specific immunoglobulin response. Consideration of this diagnosis, improved HIV screening, and understanding of the use of antigen/antibody screening tests, combined with Multispot and HIV viral RNA detection, when appropriate, can allow for early diagnosis of HIV before progression of disease and before undiagnosed patient spread the infection to new contacts.
Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...
African Journals Online (AJOL)
The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...
Human sensitization to Prosopis juliflora antigen in Saudi Arabia.
Al-Frayh, A; Hasnain, S M; Gad-El-Rab, M O; Al-Turki, T; Al-Mobeireek, K; Al-Sedairy, S T
1999-01-01
Allergenicity to Prosopis juliflora pollen antigen has been reported from only a few countries, including the US, South Africa, India and Kuwait. In some parts of Saudi Arabia, species of Prosopis have been introduced by the millions as roadside ornamentation. There appear to be four flowering seasons during which pollen grains float in all directions. However, the role of Prosopis pollen as the sensitizing and/or triggering agent of allergic asthma and/or rhinitis in the Kingdom has never been evaluated. A total of 473 allergic patients suffering from bronchial asthma in four different geographical regions (Abha, Qassim, Hofuf and Gizan), and attending allergy clinics and chest disease centers of university and Ministry of Health hospitals in the region were tested for immediate hypersensitivity reaction to Prosopis juliflora allergens. Airborne pollen grains at one center were also studied for one full year, using volumetric sampling techniques. A total of 76.1% patients in Qassim, 37.5% in Gizan, 29% in Abha and 11% in Hofuf reacted positively to Prosopis antigen. Multiple sensitivities to other pollen antigens were detected in all patients. The level of airborne Prosopis pollen detected in Gizan exceeded 90 grains m -3 of air. In view of the documented evidence of Prosopis-involved allergenicity, the role of Prosopis pollen as a sensitizing factor in Saudi Arabia has been confirmed. However, the cause of elicitation of symptoms in many multiple sensitive patients, together with the question of cross-reactivities, needs thorough and detailed investigation. In vitro confirmation of all positive results is also required to incriminate Prosopis as one of the major allergens in parts of Saudi Arabia.
Development of a dipstick assay for detection of Leishmania-specific canine antibodies
Schallig, Henk D. F. H.; Cardoso, Luís; Hommers, Marieke; Kroon, Nel; Belling, Guus; Rodrigues, Manuela; Semião-Santos, Saul J.; Vetter, Hans
2004-01-01
A dipstick assay, based on Leishmania infantum antigen, for the rapid detection of Leishmania-specific antibodies in canine serum samples was developed and evaluated. After determination of optimal dipstick test conditions, test performance was compared with two existing serological tests, i.e., the
Carcinoembryonic Antigen (CEA) in colorectal cancer follow-up
Verberne, Charlotte
2016-01-01
Colorectal cancer follow-up aims to detect recurrent disease as soon as possible, since earlier detection of recurrent disease is associated with greater chances for cure. A part of follow-up is the measurement of Carcinoembryonic Antigen (CEA) in the blood of the patient. This tumor marker is
Use of mammary epithelial antigens as markers in mammary neoplasia
International Nuclear Information System (INIS)
Ceriani, R.L.; Peterson, J.A.; Blank, E.W.
1979-01-01
Cell-type specific antigens of the mammary epithelial cells can be used as markers of breast neoplasia. Methods are proposed for the detection of metastatic mammary tissue in vivo by injection of [ 125 I]-labeled antibodies against the mammary epithelial antigens. In addition, the reduced expression of mammary epithelial cell antigens in neoplastic breast cells, quantitated here on a cell per cell basis by flow cytofluorimetry, is a marker of neoplasia and an indication of a deletion accompanying the neoplastic transformation of these cells. (Auth.)
DEFF Research Database (Denmark)
Lelie, Nico; Bruhn, Roberta; Busch, Michael
2017-01-01
BACKGROUND: Twenty-two users of individual donation nucleic acid amplification technology (ID-NAT) in six geographical regions provided detailed hepatitis B virus (HBV) infection data in first-time, lapsed, and repeat donations and classified confirmed HBV-positive donors into different infection...... categories. These data were used to compare the clinical sensitivity of hepatitis B surface antigen (HBsAg) and HBV-DNA testing. STUDY DESIGN AND METHODS: In total 10,981,776 donations from South Africa, Egypt, the Mediterranean, North and Central Europe, South East Asia, and Oceania were screened for HBV...
Detection of avian influenza antibodies and antigens in poultry and ...
African Journals Online (AJOL)
Using HI test, the wild birds were negative for AI (H5) antibodies but ELISA detected AI (NP) antibodies in Black Stork (Ciconia nigra) with an overall seroprevalence of 4.5% and mean titre of 24.50±2.400 EU. Cloacal swabs from the same species of wild birds that were tested for antibodies and 710 oropharyngeal swabs ...
Human Tumor Antigens Yesterday, Today, and Tomorrow.
Finn, Olivera J
2017-05-01
The question of whether human tumors express antigens that can be recognized by the immune system has been answered with a resounding YES. Most were identified through spontaneous antitumor humoral and cellular immune responses found in cancer patients and include peptides, glycopeptides, phosphopeptides, viral peptides, and peptides resulting from common mutations in oncogenes and tumor-suppressor genes, or common gene fusion events. Many have been extensively tested as candidates for anticancer vaccines. More recently, attention has been focused on the potentially large number of unique tumor antigens, mutated neoantigens, that are the predicted products of the numerous mutations revealed by exome sequencing of primary tumors. Only a few have been confirmed as targets of spontaneous immunity and immunosurveillance, and even fewer have been tested in preclinical and clinical settings. The field has been divided for a long time on the relative importance of shared versus mutated antigens in tumor surveillance and as candidates for vaccines. This question will eventually need to be answered in a head to head comparison in well-designed clinical trials. One advantage that shared antigens have over mutated antigens is their potential to be used in vaccines for primary cancer prevention. Cancer Immunol Res; 5(5); 347-54. ©2017 AACR . ©2017 American Association for Cancer Research.
Directory of Open Access Journals (Sweden)
Harvinder Talwar
2015-04-01
Full Text Available Sarcoidosis is a granulomatous inflammatory disease, diagnosed through tissue biopsy of involved organs in the absence of other causes such as tuberculosis (TB. No specific serologic test is available to diagnose and differentiate sarcoidosis from TB. Using a high throughput method, we developed a T7 phage display cDNA library derived from mRNA isolated from bronchoalveolar lavage (BAL cells and leukocytes of sarcoidosis patients. This complex cDNA library was biopanned to obtain 1152 potential sarcoidosis antigens and a microarray was constructed to immunoscreen two different sets of sera from healthy controls and sarcoidosis. Meta-analysis identified 259 discriminating sarcoidosis antigens, and multivariate analysis identified 32 antigens with a sensitivity of 89% and a specificity of 83% to classify sarcoidosis from healthy controls. Additionally, interrogating the same microarray platform with sera from subjects with TB, we identified 50 clones that distinguish between TB, sarcoidosis and healthy controls. The top 10 sarcoidosis and TB specific clones were sequenced and homologies were searched in the public database revealing unique epitopes and mimotopes in each group. Here, we show for the first time that immunoscreenings of a library derived from sarcoidosis tissue differentiates between sarcoidosis and tuberculosis antigens. These novel biomarkers can improve diagnosis of sarcoidosis and TB, and may aid to develop or evaluate a TB vaccine.
Antigenic typing Polish isolates of canine parvovirus
Energy Technology Data Exchange (ETDEWEB)
Mizak, B. [National Veterinary Research Institute, Pulawy (Poland); Plucienniczak, A. [Polish Academy ofd Sciences. Microbiology and Virology Center, Lodz (Poland)
1995-12-31
Polish strains of canine parvovirus isolated between 1982 and 1993 were examined to determine the extent to which the virus has evolved antigenically and genetically over eleven years. Two CPV isolates obtained in Warsaw in 1982 and Pulawy in 1993, were examined using monoclonal antibody typing, restriction analysis and sequencing VP-2 protein gene. Five other isolates from Warsaw and Pulawy were tested with the panel of monoclonal antibodies specific to CPV-2, CPV-2a and common for canine parvovirus, feline panleukopenia virus and milk enteritis virus. Results of the studies demonstrated that all isolates tested represented CPV-2a antigenic type. Rapid antigenic strain replacement recorded by Parrish and Senda in the U.S.A and Japan was not confirmed in Poland. (author). 30 refs, 2 tabs.
Antigenic typing Polish isolates of canine parvovirus
International Nuclear Information System (INIS)
Mizak, B.; Plucienniczak, A.
1995-01-01
Polish strains of canine parvovirus isolated between 1982 and 1993 were examined to determine the extent to which the virus has evolved antigenically and genetically over eleven years. Two CPV isolates obtained in Warsaw in 1982 and Pulawy in 1993, were examined using monoclonal antibody typing, restriction analysis and sequencing VP-2 protein gene. Five other isolates from Warsaw and Pulawy were tested with the panel of monoclonal antibodies specific to CPV-2, CPV-2a and common for canine parvovirus, feline panleukopenia virus and milk enteritis virus. Results of the studies demonstrated that all isolates tested represented CPV-2a antigenic type. Rapid antigenic strain replacement recorded by Parrish and Senda in the U.S.A and Japan was not confirmed in Poland. (author). 30 refs, 2 tabs
Directory of Open Access Journals (Sweden)
Huiren Xu
2016-07-01
Full Text Available Carcinoembryonic antigen (CEA has been an extensively used tumor marker responsible for clinical early diagnosis of cervical carcinomas, and pancreatic, colorectal, gastric and lung cancer. Combined with micro-electro mechanical system (MEMS technology, it is important to develop a novel immune microelectrode array (MEA not only for rapid analysis of serum samples, but also for cell detection in vitro and in vivo. In this work, we depict a simple approach to modify chitosan–multi-walled carbon nanotubes–thionine (CS–MWCNTs–THI hybrid film through one-step electrochemical deposition and the CS-MWCNTs-THI hybrid films are successfully employed to immobilize anti-CEA for fabricating simple, label-free, and highly sensitive electro-chemical immune MEAs. The detection principle of immune MEA was based on the fact that the increasing formation of the antigen-antibody immunocomplex resulted in the decreased response currents and the relationship between the current reductions with the corresponding CEA concentrations was directly proportional. Experimental results indicated that the label-free MEA had good selectivity and the limit of detection for CEA is 0.5 pg/mL signal to noise ratio (SNR = 3. A linear calibration plot for the detection of CEA was obtained in a wide concentration range from 1 pg/mL to 100 ng/mL (r = 0.996. This novel MEA has potential applications for detecting CEA for the research on cancer cells and cancer tissue slices as well as for effective early diagnosis.
A radioimmunoassay for human antibody specific for microbial antigens
International Nuclear Information System (INIS)
Tew, J.G.; Burmeister, J.; Greene, E.J.; Pflaumer, S.K.; Goldstein, J.
1977-01-01
A simple and sensitive method for detecting and quantitating antibody specific or microbial antigens is described. Bacterial, fungal, parasitic or viral antigens attached to bromoacetyl cellulose or the intact cells themselves were added to a series of two-fold dilutions of human serum. After a short incubation period, which allowed human antibody to attach to the antigens, the complex was thoroughly washed and carbon-14 labeled anti-human light chain antibody was added to each dilution. The resulting complex was washed, collected on a filter pad, placed in a scintillation vial and radioassayed. The relationship between radioactivity bound and -log 2 of the serum dilution was linear. The endpoint for each assay and a confidence interval was calculated by doing inverse prediction from simple linear regression. Results obtained using this assay indicated the presence of antibody in a pool of normal human sera specific for herpes virus and for both cell surface and intracellular antigens of Streptococcus mutans, Naegleria fowleri and Cryptococcus neoformans. In general the dominant response was against the intracellular antigens rather than cell surface antigens
Antigenic characterization of small, round-structured viruses by immune electron microscopy.
Okada, S; Sekine, S; Ando, T; Hayashi, Y; Murao, M; Yabuuchi, K; Miki, T; Ohashi, M
1990-01-01
Small, round-structured viruses (SRSVs) detected from nonbacterial gastroenteritis outbreaks in Tokyo and Saitama Prefecture, Japan, during the period from 1977 to 1988 were tentatively classified into nine antigenic patterns from SRSV-1 (S-1) to SRSV-9 (S-9) by cross-immune electron microscopy (IEM). S-1 and S-2 appeared pattern specific, while S-3 to S-9, distinguishable from each other in their reactivity, appeared somewhat antigenically related. Their antigenic relatedness to the Norwal, ...
Comparative analysis of minor histocompatibility antigens genotyping methods
Directory of Open Access Journals (Sweden)
A. S. Vdovin
2016-01-01
Full Text Available The wide range of techniques could be employed to find mismatches in minor histocompatibility antigens between transplant recipients and their donors. In the current study we compared three genotyping methods based on polymerase chain reaction (PCR for four minor antigens. Three of the tested methods: allele-specific PCR, restriction fragment length polymorphism and real-time PCR with TaqMan probes demonstrated 100% reliability when compared to Sanger sequencing for all of the studied polymorphisms. High resolution melting analysis was unsuitable for genotyping of one of the tested minor antigens (HA-1 as it has linked synonymous polymorphism. Obtained data could be used to select the strategy for large-scale clinical genotyping.
International Nuclear Information System (INIS)
Avraham, H.; Golenser, J.; Gazitt, Y.; Spira, D.T.; Sulitzeanu, D.
1982-01-01
A highly sensitive radioimmunoassay for detection of P. falciparum antibodies and antigens is described. A partially purified P. falciparum antigen preparation is obtained from in vitro cultured parasites enriched after gelatin sedimentation by sonicating the infected red blood cells and precipitating the proteins with 50% saturated ammonium sulfate. The precipitate is dissolved in buffer, ultracentrifuged and used to coat wells of microtiter plates. Anti-P. falciparum antibodies are detected by incubating antiserum dilutions in the coated wells and detecting the bound IgG with radioiodinated staphylococcal protein A. P. falciparum antigens are detected by their ability to inhibit binding of antibodies to the coated wells. Sera of individuals with a history of P. falciparum infection contain antibodies detectable at a dilution of 1:75,000. P. falciparum RBC infected in vitro can be detected at levels of parasitemia of the order of 1 parasite or less per 10 6 RBC. (Auth.)
Directory of Open Access Journals (Sweden)
Van Esbroeck Marjan
2009-05-01
Full Text Available Abstract Background Two malaria rapid diagnostic tests were evaluated in a travel clinic setting: the SD FK50 Malaria Ag Plasmodium falciparum test (a two-band test and the SD FK60 Malaria Ag P. falciparum/Pan test (a three-band test. Methods A panel of stored whole blood samples (n = 452 and n = 614 for FK50 and FK60, respectively from returned travellers was used. The reference method was microscopy with PCR in case of discordant results. Results For both tests, overall sensitivity for the detection of P. falciparum was 93.5%, reaching 97.6% and 100% at parasite densities above 100 and 1,000/μl respectively. Overall sensitivities for Plasmodium vivax, Plasmodium ovale and Plasmodium malariae for the FK60 test were 87.5%, 76.3% and 45.2%, but they reached 92.6% and 90.5% for P. vivax and P. ovale at parasite densities above 500/μl. Specificities were above 95% for all species and both tests when corrected by PCR, with visible histidine-rich protein-2 lines for P. malariae (n = 3 and P. vivax and P. ovale (1 sample each. Line intensities were reproducible and correlated to parasite densities. The FK60 tests provided clues to estimate parasite densities for P. falciparum below or above 1,000/μl. Conclusion Both the FK50 and FK60 performed well for the diagnosis of P. falciparum in the present setting, and the FK60 for the diagnosis of P. vivax and P. ovale at parasite densities > 500/μl. The potential use of the FK60 as a semi-quantitative estimation of parasite density needs to be further explored.
A comparison of labelled antibody methods for the detection of virus antigens in cell monolayers
International Nuclear Information System (INIS)
Oram, J.D.; Crooks, A.J.
1979-01-01
A number of labelled antibody methods have been applied to the detection of Semliki Forest virus antigens after replication of the virus in monolayers of host cells in multi-well polystyrene plates. The importance of several reaction variables has been investigated and the sensitivity of the methods compared for different periods of virus replication. Direct assays with radio-labelled antibody (RLA) and indirect assays peroxidase-antiperoxidase complexes (PAP) were equally sensitive. Direct and indirect assays using enzyme-linked antibodies (ELA) were slightly less sensitive than the direct RLA and PAP methods but were more sensitive than the indirect RLA or fluorescent antibody (FLA) methods. Direct assays using ELA were more rapid and easier to perform than the other assay methods. (Auth.)
Li, Geng; Ali, Selman A; McArdle, Stephanie E B; Mian, Shahid; Ahmad, Murrium; Miles, Amanda; Rees, Robert C
2005-01-01
During the last decade, a large number of human tumour antigens have been identified. These antigens are classified as tumour-specific shared antigens, tissue-specific differentiation antigens, overexpressed antigens, tumour antigens resulting from mutations, viral antigens and fusion proteins. Antigens recognised by effectors of immune system are potential targets for antigen-specific cancer immunotherapy. However, most tumour antigens are self-proteins and are generally of low immunogenicity and the immune response elicited towards these tumour antigens is not always effective. Strategies to induce and enhance the tumour antigen-specific response are needed. This review will summarise the approaches to discovery of tumour antigens, the current status of tumour antigens, and their potential application to cancer treatment.
DEFF Research Database (Denmark)
Wiedemann, Annegret; Kakoschke, Tamara Katharina; Speth, Cornelia
2016-01-01
tDetection of carbohydrate antigens is an important means for diagnosis of invasive fungal infections. Fordiagnosis of systemic Aspergillus infections, galactomannan is commonly used, the core antigenic struc-ture of which consists of chains of several galactofuranose moieties. In this study, we ....... fumigatus and Fusar-ium hyphae in immunohistology. Moreover, since Fusarium releases the AB135-8 antigen, it appears tobe a promising target antigen for a serological detection of Fusarium infections....
Multiplex real-time PCR for identification of canine parvovirus antigenic types.
Kaur, Gurpreet; Chandra, Mudit; Dwivedi, P N; Narang, Deepti
2016-07-01
Canine parvovirus (CPV) is an important disease causing gastroenteritis and/or haemorrhagic gastroenteritis in dogs. There are four antigenic types of CPV reported worldwide viz. CPV 2, CPV 2a, CPV 2b and CPV 2c. The diagnosis of CPV with the identification of the antigen type responsible remains problematic. In the present study, identification as well as antigenic typing of CPV was done using a de novo multiplex real time PCR to combat the problem of antigenic type identification. From the study it could be concluded that the here developed multiplex real time PCR assay could be used for rapid detection of CPV as well as typing of its three antigenic types. Copyright © 2016 Elsevier B.V. All rights reserved.
Litster, A L; Pogranichniy, R; Lin, T-L
2013-11-01
The antemortem diagnosis of feline infectious peritonitis (FIP) remains challenging in clinical practice, since current testing methods have suboptimal diagnostic accuracy. Immunohistochemical testing of biopsy specimens and postmortem examination are the standard diagnostic methods, although direct immunofluorescence (DIF) testing to detect feline coronavirus in macrophages in effusion specimens has been reported to have 100% specificity and has been recommended as an antemortem confirmatory test. The aim of this study was to compare the results of DIF testing in antemortem feline effusions with postmortem results using field samples. Effusion specimens were collected antemortem from 17 cats and tested by DIF, followed by postmortem examination. Histopathological examination of specimens collected at postmortem confirmed FIP in 10/17 cases and ruled out FIP out in 7/17 cases. Antemortem DIF testing was positive in all 10 cases confirmed as FIP at postmortem examination. In the seven cats where FIP was ruled out at postmortem examination, DIF was negative in five cases and positive in the remaining two cases. The calculated sensitivity of DIF testing was 100% and the specificity was 71.4%. Duplicate effusion specimens from eight cats that were initially DIF positive were stored refrigerated (4 °C) or at room temperature (22-25 °C) and subjected to serial DIF testing to determine the duration of positive results. DIF-positive specimens stored at both temperatures retained their positive status for at least 2 days. Copyright © 2013 Elsevier Ltd. All rights reserved.
Directory of Open Access Journals (Sweden)
Ammayappan Arun
2009-10-01
Full Text Available Abstract Background Avian influenza viruses, belonging to the family Orthomyxoviridae, possess distinct combinations of hemagglutinin (H and the neuraminidase (N surface glycoproteins. Typing of both H and N antigens is essential for the epidemiological and surveillance studies. Therefore, it is important to find a rapid, sensitive, and specific method for their assay, and ELISA can be useful for this purpose, by using recombinant proteins. Results The nucleoprotein (NP and truncated neuraminidase subtype 3 and 7 of avian influenza virus (AIV were expressed in Saccharomyces cerevisiae and used to develop an indirect enzyme-linked immunosorbent assay for antibody detection. The developed assays were evaluated with a panel of 64 chicken serum samples. The performance of NP-ELISA was compared with the commercially available ProFlok® AIV ELISA kit. The results showed comparable agreement and sensitivity between the two tests, indicating that NP-ELISA assay can be used for screening the influenza type A antibody in AIV infected birds. The N3 and N7- ELISAs also reacted specifically to their type specific sera and did not exhibit any cross-reaction with heterologous neuraminidase subtype specific sera. Conclusion The study demonstrates the expression of the NP, N3, and N7 proteins of AIV in yeast (S. cerevisiae and their application in developing an indirect ELISA for detecting NP, N3 and N7 antibodies from AIV-infected chicken sera. The described indirect ELISAs are rapid, sensitive, specific and can be used as promising tests during serological surveillance.
Galanti, L M; Cornu, C; Masson, P L; Robert, A R; Becheanu, D; Lamy, M E; Cambiaso, C L
1991-05-01
An assay of anti-HBs antibodies based on agglutination of latex particles coated with recombinant HBs-antigen was compared with Abbott radioimmunoassay (Abbott-RIA), which uses a human plasma-derived antigen. The population examined consisted of 76 Abbott-RIA anti-HBs-negative prevaccinated subjects and 1044 serum samples anti-HBs found positive by Abbott-RIA, including 283 samples of subjects vaccinated either with a human plasma-derived vaccine (group A; n = 180) or with a recombinant vaccine (group B; n = 103). Correlation coefficients between the two techniques were respectively r = 0.89 for the whole population (n = 1044), r = 0.98 in group A and r = 0.74 in group B. Anti-HBs titres were higher with latex than with RIA in group B as shown by the regression slopes: latex = 508 + 1.11 RIA in group A and latex = -1138 + 3.97 RIA in group B, suggesting that some vaccinated subjects from group B produced antibodies against epitopes proper to the recombinant antigen. In the prevaccinated population and in group A, the latex results were compared with those of radioimmunoassays (Abbott, Sorin) and enzyme immunoassays (Behring, Roche, Pasteur). Only the Roche-EIA detected anti-HBs in the prevaccinated subjects. The correlation between the various immunoassays was r greater than 0.96 only for values higher than 100 IU/l.
News and views on tumor markers: The use of radioactive antibodies against cell-bound antigens
International Nuclear Information System (INIS)
Kleist, S. von
1984-01-01
It was doubtless due to the phenomenal progress in the field of tumor immunology that took place during the last 20 years, that today we dispose not only of highly sensitive immunological tests like the RIA or EIA, but also of most specific reagents like monospecific polyclonal and monoclonal antibodies. In this context the discovery in human carcinomas of tumor-associated antigens was of prime importance, especially since some of them were found to have clinical relevance as so-called tumor markers. It has been shown that there is a direct correlation between the absolute tumor burden and the blood concentration of these substances. Based on animal models a new technology for tumor and metastases detection was developed in recent years, that used polyvalent or monoclonal antibodies prepared against tumor-associated antigens. This technique called radioimmuno-detection (RAID), especially in the hands of experts, may be superior in many instances to conventional radiology, radionuclide scanning or ultra-sonographic techniques. (orig.) [de
International Nuclear Information System (INIS)
Imai, M.; Nomura, M.; Gotanda, T.; Sano, T.; Tachibana, K.; Miyamoto, H.; Takahashi, K.; Toyama, S.; Miyakawa, Y.; Mayumi, M.
1982-01-01
Mice were immunized against hepatitis B e antigen (HBeAg) isolated from sera of asymptomatic carriers of hepatitis B virus. Their spleen cells were fused with mouse myeloma (NS-1) cells, and 5 clones of hybridoma cells secreting antibody against HBeAg (anti-HBe) were isolated. For the production of anti-HBe in large scale, cells were cultivated both in vitro and in the peritoneal cavity of ascitic mice. Although monoclonal antibodies produced by these clones showed a strong reactivity of anti-HBe in hemagglutination tests, individual monoclonal anti-HBe did not reveal any precipitin line in immunodiffusion. When 2 of the 5 monoclonal antibodies were mixed together, however, some combinations showed a precipitin line against HBeAg, whereas others did not. Utilizing solid-phase radioimmunoassay involving a number of combinations of monoclonal antibodies used for solid-phase and radiolabeling, the 5 antibodies were classified into 2 groups. Three of the anti-HBe antibodies were found to be directed to 1 determinant of HBeAg (determinant a); the remaining 2 to the other determinant (determinant b). Determinants a and b were detected on HBeAg in the serum, as well as on the polypeptide of 19,000 daltons (P19) derived from the nucleocapsid of hepatitis B virus. Monoclonal anti-HBe antibodies with different specificities may provide useful tools in delineating the antigenic structure of HBeAg and also in evaluating immune responses of the host directed to its subdeterminants
Rösler, Uwe; Szabo, Istvan; Matthies, Claudia; Albrecht, Kerstin; Leffler, Kerstin; Scherer, Kathrin; Nöckler, Karsten; Lehmann, Jörg; Methner, Ulrich; Hensel, Andreas
2018-01-01
The objective of this study was the comparative evaluation of four indirect Salmonella ELISA tests at study time approved in Germany to detect Salmonella infection in pigs. Three tests are based on a LPS-antigen mix and directed against specific IgG antibodies. The fourth test is based on a purified S. Typhimurium whole-cell lysate antigen and discriminates between Salmonella-specific IgM-, IgA-, and IgG- antibodies. In a longitudinal study, two groups of six weeks old hybrid piglets were ...
Determinants of wheat antigen and fungal alpha-amylase exposure in bakeries.
Burstyn, I; Teschke, K; Bartlett, K; Kennedy, S M
1998-05-01
The study's objectives were to measure flour antigen exposure in bakeries and define the determinants of exposure. Ninety-six bakery workers, employed in seven different bakeries, participated in the study. Two side-by-side full-shift inhalable dust samples were obtained from each study participant on a single occasion. The flour antigen exposure was measured as wheat antigen and fungal alpha-amylase content of the water-soluble fraction of inhalable dust, assayed via enzyme-linked immunosorbent assays. During the entire sampling period bakers were observed and information on 14 different tasks was recorded at 15-minute intervals. Other production characteristics were also recorded for each sampling day and used in statistical modeling to identify significant predictors of exposure. The mean alpha-amylase antigen exposure was 22.0 ng/m3 (ranging from below the limit of detection of 0.1 ng/m3 to 307.1 ng/m3) and the mean wheat antigen exposure was 109 micrograms/m3 (ranging from below the limit of detection of 1 microgram/m3 to 1018 micrograms/m3). Regression models that explained 74% of variability in wheat antigen and alpha-amylase antigen exposures were constructed. The models indicated that tasks such as weighing, pouring, and operating dough-brakers increased flour antigen exposure, while packing and decorating resulted in lower exposures. Croissant, puff-pastry, and bread/bun production lines were associated with increased exposure, while cake production and substitution of dusting with the use of divider oil were associated with decreased exposure. Exposure levels can be reduced by the automation of forming tasks, alteration of tasks requiring pouring of flour, and changes to the types of products manufactured.
Improvement of an enzyme immunosorbent assay for detecting antibodies against Dioctophyma renale.
Pedrassani, Daniela; do Nascimento, Adjair Antonio; André, Marcos Rogério; Machado, Rosangela Zacarias
2015-09-15
An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine. Copyright © 2015 Elsevier B.V. All rights reserved.
Matovina, Emil; Mihailović, Jasna; Nikoletić, Katarina; Srbovan, Dolores
2015-01-01
Early detection of recurrence is an important factor for long term survival of patients with colorectal cancer. Measurement of serum levels of carcinoembryonic antigen has been commonly used in the postoperative surveillance of colorectal cancer. The purpose of this study was to evaluate the ability of positron emission tomography-computed tomography to detect pathological substrate of elevated serum carcinoembryonic antigen in patients with colorectal cancer. The patients with colorectal cancer who underwent curative surgical resection and/ or chemotherapy, who were found in our database, were analyzed retrospectively. Forty-eight 18F-fluorodeoxyglucose positron emission tomography-computed tomography studies including 45 patients (14 women, 31 men; mean age: 62.93 years) with elevated serum, carcinoembryonic antigen levels, which had been performed between January 2011 and January 2014, were evaluated. Serum levels of carcinoembryonic antigen were measured within 3 months after positron emission tomography-computed tomography examination. Final diagnosis of recurrence was made by histopathological findings, radiology studies or clinical follow-up. Recurrences were diagnosed in 37 patients, the prevalence being 77.1%. Liver metastases were found in 18 patients, abdominal, pelvic and/or mediastinal lymph nodes were positive in 19 patients, 11 patients had loco regional recurrences and 4 patients had pulmonary metastasis, and bone metastases were found in one patient. One patient was diagnosed with metastasis in scar tissue. The overall sensitivity and specificity of positron emission tomography-computed tomography was 90.24% and 71.42%, respectively. The positive and negative predictive values were 94.87% and 55.56%, respectively. 18F-fluorodeoxyglucose positron emission tomography-computed tomography is a powerful tool that could be used in determining colorectal cancer recurrence in patients with elevated carcinoembryonic antigen levels and could have an
Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C
2012-12-21
Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in
International Nuclear Information System (INIS)
Doku, C.K.; Seidu, I.B.M.
1997-01-01
Preliminary results are presented of the analysis of 3000 serum samples collected from Zebu cattle in the Nabogu valley. Of the 3000 serum samples collected so far, 182 have been tested using the buffy coat technique (BCT) and the antigen ELISA test. A total of 56 samples have been found positive by both techniques. Using the parasitological technique (=BCT) 44 samples were diagnosed to be positive, while the Ag-ELISA detected 19 positive samples. The majority (75%) of cases detected positive by either technique was due to a single infection by Trypanosoma brucei. (author). 4 refs, 1 fig., 3 tabs
Energy Technology Data Exchange (ETDEWEB)
Doku, C K; Seidu, I B.M. [Central Veterinary Lab., Pong-Tamale (Ghana). Tsetse and Trypanosmosis Unit
1997-02-01
Preliminary results are presented of the analysis of 3000 serum samples collected from Zebu cattle in the Nabogu valley. Of the 3000 serum samples collected so far, 182 have been tested using the buffy coat technique (BCT) and the antigen ELISA test. A total of 56 samples have been found positive by both techniques. Using the parasitological technique (=BCT) 44 samples were diagnosed to be positive, while the Ag-ELISA detected 19 positive samples. The majority (75%) of cases detected positive by either technique was due to a single infection by Trypanosoma brucei. (author). 4 refs, 1 fig., 3 tabs.
Identification of protective antigens for vaccination against systemic salmonellosis
Directory of Open Access Journals (Sweden)
Dirk eBumann
2014-08-01
Full Text Available There is an urgent medical need for improved vaccines with broad serovar coverage and high efficacy against systemic salmonellosis. Subunit vaccines offer excellent safety profiles but require identification of protective antigens, which remains a challenging task. Here, I review crucial properties of Salmonella antigens that might help to narrow down the number of potential candidates from more than 4000 proteins encoded in Salmonella genomes, to a more manageable number of 50-200 most promising antigens. I also discuss complementary approaches for antigen identification and potential limitations of current pre-clinical vaccine testing.
Improved immunocytochemical detection of daunomycin
DEFF Research Database (Denmark)
Ohara, Koji; Shin, Masashi; Larsson, Lars-Inge
2007-01-01
and mitochondria of heart muscle cells may help to improve our understanding of the cardiac toxicity of DM and related anthracyclin antibiotics. A number of ELISA tests were carried out in order to elucidate the mechanisms of H2O2-assisted antigen retrieval. A possible mechanism is that DM is reduced and converted......Improved immunocytochemical (ICC) detection of the anthracycline anticancer antibiotic daunomycin (DM) has been achieved by used of hydrogen peroxide oxidation prior to ICC staining for DM. The new method greatly enhanced the localization of DM accumulation in cardiac, smooth and skeletal muscle...... to its semiquinone and/or hydroquinone derivative in vivo. Oxidation by hydrogen peroxide acts to convert these derivatives back to the native antigen. The improved ICC methodology using oxidation to recreated native antigens from reduced metabolites may be helpful also with respect to the localization...
DEFF Research Database (Denmark)
Samuelsen, Simone V; Maity, Arindam; Nybo, Mads
2016-01-01
Reliable measurement of clinically relevant autoimmune antibodies toward phospholipid-protein conjugates is highly desirable in research and clinical assays. To date, the development in this field has been limited to the use of natural heterogeneous antigens. However, this approach does not take ...... on the correlation of detected autoantibodies with disease activity and manifestations. This confirms the crucial importance of antigens' composition on research and diagnostic assays, and opens up exciting perspectives for synthetic antigens in future studies of autoimmunity.......Reliable measurement of clinically relevant autoimmune antibodies toward phospholipid-protein conjugates is highly desirable in research and clinical assays. To date, the development in this field has been limited to the use of natural heterogeneous antigens. However, this approach does not take...... structural features of biologically active antigens into account and leads to low reliability and poor scientific test value. Here we describe novel phospholipid-protein conjugates for specific detection of human autoimmune antibodies. Our synthetic approach includes mild oxidation of synthetic phospholipid...
Sima, Michal; Ferencova, Blanka; Warburg, Alon; Rohousova, Iva; Volf, Petr
2016-03-01
Certain salivary proteins of phlebotomine sand flies injected into the host skin during blood-feeding are highly antigenic and elicit strong antibody-mediated immune responses in repeatedly-exposed hosts. These antibodies can be measured by enzyme-linked immuno sorbent assays (ELISAs) using salivary gland homogenates (SGHs) as the source of antigens and serve as a markers for exposure to biting sand flies. Large-scale screening for anti-sand fly saliva antibodies requires replacement of SGH with recombinant salivary proteins. In East Africa, Phlebotomus orientalis is the main vector of Leishmania donovani, a trypanosomatid parasite causing visceral leishmaniasis. We tested recombinant salivary proteins derived from Ph. orientalis saliva to study exposure of domestic animals to this sand fly species. Antigenic salivary proteins from Ph. orientalis were identified by immunoblot and mass spectrometry. Recombinant apyrase rPorSP15, yellow-related protein rPorSP24, ParSP25-like protein rPorSP65, D7-related protein rPorSP67, and antigen 5-related protein rPorSP76 were tested using ELISA with sera of domestic animals from L. donovani foci in Ethiopia where Ph. orientalis is present. Our results highlighted recombinant yellow-related protein rPorSP24 as the most promising antigen, displaying a high positive correlation coefficient as well as good sensitivity and specificity when compared to SGH. This recombinant protein was the most suitable one for testing sera of dogs, sheep, and goats. In addition, a different antigen, rPorSP65 was found efficacious for testing canine sera. Recombinant salivary proteins of Ph. orientalis, specifically rPorSP24, were shown to successfully substitute SGH in serological experiments to measure exposure of domestic animals to Ph. orientalis, the vector of L. donovani. The results suggest that rPorSP24 might be a suitable antigen for detecting anti-Ph. orientalis antibody-mediated reactions also in other host species.
Directory of Open Access Journals (Sweden)
Mahmoud Nateghi Rostami
2016-06-01
Full Text Available Background: Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen worldwide. Early detection and treatment of C.trachomatis genital infection prevent serious reproductive complications. Objective: Performances of enzyme immunoassay (EIA and major outer membrane protein (MOMP-polymerase chain reaction (PCR for diagnosis of genital C.trachomatis infection in women were compared. Materials and Methods: In this cross sectional study a total of 518 women volunteers were included (33.67±8.3 yrs who had been referred to Gynecology clinics of Qom province, Iran, were included. Endocervical swab specimens were collected to detect lipopolysaccharide (LPS antigen in EIA and to amplify MOMP gene of C.trachomatis in PCR. Results were confirmed using ompI nested-PCR. Sensitivity, specificity, positive (PPV and negative predictive values (NPV were calculated for performance of the tests. Odds ratios were determined using binary logistic regression analysis. Results: In total, 37 (7.14% cases were positive by EIA and/or MOMP-PCR. All discrepant results were confirmed by nested-PCR. Sensitivity, specificity, PPV and NPV values of EIA were 59.46%, 100%, 100% and 96.98%, and those of MOMPPCR were 97.30%, 100%, 100%, 99.79%, respectively. Reproductive complications including 2.7% ectopic pregnancy, 5.4% stillbirth, 5.4% infertility, and 10.8% PROM were recorded. The risk of developing chlamydiosis was increased 4.8-fold in volunteers with cervicitis (p<0.05; OR 4.80; 95% CI 1.25-18.48. Conclusion: C.trachomatis infection should be regarded in women of reproductive ages especially those with cervicitis. Primary screening of women by using the low cost antigen-EIA is recommended; however, due to the low sensitivity of Ag-EIA, verification of the negative results by a DNA amplification method is needed.
Differential antigenic protein recovery from Taenia solium cyst tissues using several detergents.
Navarrete-Perea, José; Orozco-Ramírez, Rodrigo; Moguel, Bárbara; Sciutto, Edda; Bobes, Raúl J; Laclette, Juan P
2015-07-01
Human and porcine cysticercosis is caused by the larval stage of the flatworm Taenia solium (Cestoda). The protein extracts of T. solium cysts are complex mixtures including cyst's and host proteins. Little is known about the influence of using different detergents in the efficiency of solubilization-extraction of these proteins, including relevant antigens. Here, we describe the use of CHAPS, ASB-14 and Triton X-100, alone or in combination in the extraction buffers, as a strategy to notably increase the recovery of proteins that are usually left aside in insoluble fractions of cysts. Using buffer with CHAPS alone, 315 protein spots were detected through 2D-PAGE. A total of 255 and 258 spots were detected using buffers with Triton X-100 or ASB-14, respectively. More protein spots were detected when detergents were combined, i.e., 2% CHAPS, 1% Triton X-100 and 1% ASB-14 allowed detection of up to 368 spots. Our results indicated that insoluble fractions of T. solium cysts were rich in antigens, including several glycoproteins that were sensitive to metaperiodate treatment. Host proteins, a common component in protein extracts of cysts, were present in larger amounts in soluble than insoluble fractions of cysts proteins. Finally, antigens present in the insoluble fraction were more appropriate as a source of antigens for diagnostic procedures. Copyright © 2015 Elsevier B.V. All rights reserved.
de Wert, Guido; Liebaers, Inge; Van de Velde, Hilde
2007-09-01
There has been increasing support for combining preimplantation genetic diagnosis (PGD) for specific diseases with a test for human leukocyte antigens (HLA) because the generation of HLA-matched umbilical cord blood cells may save the life of a diseased sibling. To date, this procedure has taken place in the context of conceiving another child--PGD/HLA testing type 1. However, it may well become possible to perform PGD/HLA testing outside this context, that is, to select matched embryos from which embryonic stem cells could be derived and used in cell therapy--PGD/HLA testing type 2. A proactive ethical analysis is needed and is presented in this article. Although PGD/HLA testing type 1 can be morally justified, the risks, pitfalls, and practical limitations of this procedure make it necessary to develop alternative strategies. PGD/HLA testing type 2 may provide an alternative strategy. From an ethical point of view, the controversial issue is that this procedure creates embryos purely for instrumental use. However, given the dominant view that the preimplantation embryo has only limited moral value, this alternative may be as morally justified as PGD/HLA testing type 1.
Ciuchini, Franco; Adone, Rosanna; Pasquali, Paolo
2002-01-01
This study showed that vaccination of cattle with Brucella abortus rough strain RB51 induces incomplete antibodies that can be detectable by a Coombs antiglobulin test using the B. abortus 99 smooth strain.
Lewis antigen mediated adhesion of freshly removed human bladder tumors to E-selectin
DEFF Research Database (Denmark)
Skorsteensgaard, Karna; Vestergaard, Else Marie; Langkilde, Niels
1999-01-01
PURPOSE: Twenty fresh surgical specimens of human bladder tumors were tested for their ability to adhere to recombinant P and E-selectin. The adhesion was correlated to immunological detection of carbohydrate structures. MATERIALS AND METHODS: A static titertray assay with immobilized selectins.......003), whereas no correlation was found to secretor and Lewis genotypes. CONCLUSIONS: These data on clinical specimens indicate that Lewis antigen mediated E-selectin adhesion may play a role in the human bladder cancer disease....
Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z
1990-01-01
A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.
Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A
1999-01-01
The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.
Directory of Open Access Journals (Sweden)
Ondigo Bartholomew N
2012-12-01
Full Text Available Abstract Background Multiplex cytometric bead assay (CBA have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.
International Nuclear Information System (INIS)
Tamsel, S.; Killi, R.; Demirpolat, G.; Hekimgil, M.; Soydan, S.; Altay, B.
2008-01-01
We carried out a retrospective study to review the efficiency of grey-scale transrectal ultrasonography (TRUS) in detecting prostate cancer compared with the data in recent published work, including alternative imaging methods of the prostate gland. Our study group consisted of 830 patients who underwent TRUS-guided biopsy of the prostate between May 2000 and June 2004. The relation between abnormal TRUS findings and serum total prostate-specific antigen (tPSA) levels was evaluated in patients with prostate cancer who were divided into three different groups according to serum tPSA levels. Group I included patients with tPSA levels of 4-9.9 ng/mL, group II included tPSA levels of 10-19.9 ng/mL and group III included patients with tPSA levels of 20 ng/mL or more. In general, TRUS detected 185 (64%) of 291 cancers with a specificity of 89%, a PPV of 76% and an accuracy of 80%. TRUS findings enabled the correct identification of 22 (56%) of the 39 cancers in group I, 28 (30%) of the 93 cancers in group II and 135 (85%) of the 159 cancers in group III. In conclusion, TRUS alone has a limited potential to identify prostate cancer, especially in patients with tPSA levels lower than 20 ng/mL. Therefore, increased numbers of systematically placed biopsy cores must be taken or alternative imaging methods are required to direct TRUS-guided biopsy for improving prostate cancer detection.
Cloning and Expressing Recombinant Protective Antigen Domains of B. anthracis
2011-09-01
future predictive modeling toolkits. 1 1. Introduction The use of Bacillus anthracis as a bio - weapon in the United States in 2001 affirmed the need...for improved sensing and detection of biological weapons of mass destruction (WMD). Protective Antigen (PA) protein of Bacillus anthracis is the...Cloning and Expressing Recombinant Protective Antigen Domains of B. anthracis by Deborah A. Sarkes, Joshua M. Kogot, Irene Val-Addo
Radionuclide-labelled antigens in serological epidemiology
International Nuclear Information System (INIS)
Felsenfeld, O.; Parrott, M.W.
1977-01-01
The feasibility of tests using radionuclide-labelled antigens in serological surveys was studied, with particular attention to the likely availability of facilities and personnel in the tropics and arctics, where measurements may be disturbed by climatic influences. The methodology required was to be simple, rapid and suitable for examining large numbers of sera, as for epidemological surveys. In the introduction, limitations of labelled antigen tests are discussed, the choice of radionuclide and measurement methods, test procedures and evaluation of results. Collection, preservation and shipment of speciments (serum, faeces, cerebrospinal fluid, sputum, etc.) are described. Experiments with bacteria and bacterial toxins (Enterobacteriaceae, vibrios, staphylococci, meningococci, etc.), with protozoa and metazoa (Entamoeba hystolytica, Schistosoma mansoni, Trypanosoma cruzi, Plasmodia and other parasites), with viruses (vaccinia, adeno-, polio-, and influenza viruses, etc.), and with fungi are discussed
Infrequent Expression of the Cancer-Testis Antigen, PASD1, in Ovarian Cancer
Directory of Open Access Journals (Sweden)
Ghazala Khan
2015-01-01
Full Text Available Ovarian cancer is very treatable in the early stages of disease; however, it is usually detected in the later stages, at which time, treatment is no longer as effective. If discovered early (Stage I, there is a 90% chance of five-year survival. Therefore, it is imperative that early-stage biomarkers are identified to enhance the early detection of ovarian cancer. Cancer-testis antigens (CTAs, such as Per ARNT SIM (PAS domain containing 1 (PASD1, are unique in that their expression is restricted to immunologically restricted sites, such as the testis and placenta, which do not express MHC class I, and cancer, making them ideally positioned to act as targets for immunotherapy as well as potential biomarkers for cancer detection where expressed. We examined the expression of PASD1a and b in a number of cell lines, as well as eight healthy ovary samples, eight normal adjacent ovarian tissues, and 191 ovarian cancer tissues, which were predominantly stage I ( n = 164 and stage II ( n = 14 disease. We found that despite the positive staining of skin cancer, only one stage Ic ovarian cancer patient tissue expressed PASD1a and b at detectable levels. This may reflect the predominantly stage I ovarian cancer samples examined. To examine the restriction of PASD1 expression, we examined endometrial tissue arrays and found no expression in 30 malignant tumor tissues, 23 cases of hyperplasia, or 16 normal endometrial tissues. Our study suggests that the search for a single cancer-testes antigen/biomarker that can detect early ovarian cancer must continue.
Abdolahi Khabisi, Samaneh; Sarkari, Bahador; Moshfe, Abdolali; Jalali, Sedigheh
2017-02-01
Parasitological methods are not helpful for the diagnosis of fascioliasis in acute and invasive periods of the disease. Detection of coproantigens seems to be a suitable alternative approach in the diagnosis of fascioliasis. The present study aimed to develop a reliable antigen detection system, using monoclonal antibodies raised against excretory-secretory (ES) antigen of Fasciola hepatica, for the diagnosis of fascioliasis. Fasciola adult worms were collected from the bile ducts of infected animals. Species of the fluke was determined by polymerase chain reaction-restriction fragment length polymorphism (RFLP-PCR). ES antigen of F. hepatica was prepared. For production of monoclonal antibodies, mice were immunized with ES antigens of F. hepatica. Spleen cells from the immunized mice were fused with NS-1 myeloma cells, using polyethylene glycol. Hybridoma cells secreting specific antibody were expanded and cloned by limiting dilution. Moreover, polyclonal antibody was produced against F. hepatica ES antigen in rabbits. A capture enzyme-linked immunosorbent assay (ELISA) system, using produced monoclonal antibody, was designed and stool samples of infected animals along with control samples were tested by the system. The capture ELISA detected the coproantigen in 27 of 30 (90%) parasitologically confirmed fascioliasis cases, while 4 of 39 (10.25%) samples infected with other parasitic infections showed a positive reaction in this system. No positive reactivity was found with healthy control samples. Accordingly, sensitivity of 90% and specificity of 94.2% were obtained for the capture ELISA system. The results were compared with those obtained with commercial BIO-X ELISA, and a very good (kappa = 0.9) agreement was found between the commercial kit and the developed capture ELISA. Findings of this study showed that the produced monoclonal antibody has appropriate performance for the detection of Fasciola coproantigen in stool samples and can be appropriately
Dog Erythrocyte Antigen 1 (DEA 1): Mode of Inheritance and Initial Characterization
Polak, Klaudia; Acierno, Michelle; Raj, Karthik; Mizukami, Keijiro; Siegel, Don L.; Giger, Urs
2015-01-01
Background The Dog Erythrocyte Antigen (DEA) 1 blood group system remains poorly defined. Objectives The purpose of the study was to determine the DEA 1 mode of inheritance and to characterize the DEA 1 antigen and alloantibodies. Animals Canine research colony families, clinic canine patients, and DEA 1.2+ blood bank dogs were studied. Methods Canine blood was typed by flow cytometry and immunochromatographic strips using anti-DEA 1 monoclonal antibodies. Gel column experiments with polyclonal and immunoblotting with monoclonal anti-DEA 1 antibodies were performed to analyze select samples. Cross-reactivity of human typing reagents against canine RBCs and one monoclonal anti-DEA 1 antibody against human RBC panels was assessed. Results Typing of 12 families comprising 144 dogs indicated an autosomal dominant inheritance with ≥4 alleles: DEA 1− (0) and DEA 1+ weak (1+), intermediate (2+) and strong (3+ and 4+). Samples from 6 dogs previously typed as DEA 1.2+ were typed as DEA 1+ or DEA 1− using monoclonal antibodies. Human typing reagents produced varied reactions in tube agglutination experiments against DEA 1+ and DEA 1− RBCs. Polypeptide bands were not detected on immunoblots using a monoclonal anti-DEA 1 antibody, therefore the anti-DEA 1 antibody may be specific for conformational epitopes lost during denaturation. Conclusions The autosomal dominant inheritance of DEA 1 with ≥4 alleles indicates a complex blood group system; the antigenicity of each DEA 1+ type will need to be determined. The biochemical nature of the DEA 1 antigen(s) appears different from human blood group systems tested. PMID:26291052
Comparison of Rapid Malaria Test and Laboratory Microscopy ...
African Journals Online (AJOL)
Michael Horsfall
ABSTRACT: Blood samples collected from 272 volunteers in two communities of Bayelsa State in the Niger. Delta area were investigated for falciparum malaria parasite using the rapid test based on the detection of soluble antigen and laboratory microscopy test. The data showed that out of the 272 samples collected, ...
Genchi, Marco; Mangia, Carlo; Ferrari, Nicola; Loukeri, Sofia
2018-01-01
The performance of a rapid immunochromatographic test for the detection of Dirofilaria immitis antigens (Speed Diro™; BVT-Virbac, France) was assessed in 49 experimentally infected dogs and in 244 naturally infected animals; 142 dogs and 102 cats. In experimentally infected dogs, Speed Diro™ showed a sensitivity of 90.9% in dogs infected with one adult female worm and 100% in dogs infected with more than one female worm. Specificity was 100%. For naturally infected dogs, the Knott test and PetChek ® HTWM PF served as reference methods for microfilaremia and antigenemia, respectively. All microfilaemic dogs (55/142) were positive with Speed Diro™. Importantly, none of the 21 dogs infected with D. repens were positive. The results of Speed Diro™ for the detection of antigenemia were compared with two in-house tests, SNAP ® HTWM and Witness ® Dirofilaria, and all three tests were 100% specific and sensitive in comparison to PetChek ® HTWM PF. For the evaluation of feline samples, 102 cats were examined by echocardiography. Sera from 87 heartworm-infected cats were tested by Speed Diro™ and SNAP ® HTWM. The results of Speed Diro™ were equivalent to SNAP ® HTWM, with a sensitivity of 98.9% and a specificity of 100%.
Hamed, Maged Abdel Galil; Basha, Mohammad Abd Alkhalik; Ahmed, Hussien; Obaya, Ahmed Ali; Afifi, Amira Hamed Mohamed; Abdelbary, Eman H
2018-06-20
68 Ga-prostate-specific membrane antigen-11 ( 68 Ga-PSMA-11) is a recently developed positron emission tomography (PET) tracer that can detect prostate cancer (PC) relapses and metastases with high contrast resolution. The aim of this study was to assess the detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT image in patients with rising prostatic-specific antigen (PSA) after treatment of PC. The present prospective study included 188 patients who exhibited rising of PSA level on a routine follow-up examination after definitive treatment of PC. All patients underwent a 68 Ga-PSMA PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value of the local recurrence and extraprostatic metastases. The detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT were established by histopathology and clinical and imaging follow-up as the reference standards. 68 Ga-PSMA PET/CT detected tumour relapse in 165 patients (35 patients had local recurrence, 106 patients had extraprostatic metastases, and 24 patients had combined lesions). The sensitivity, specificity, and accuracy values of 68 Ga-PSMA PET/CT examination in the detection of PC recurrence were 98.8%, 100%, and 98.8%, respectively. 68 Ga-PSMA PET/CT revealed an overall detection rate of 87.8% (165/188) in patients with rising PSA (median of 2.2 ng/mL, and range of 0.01-70 ng/mL). 68 Ga-PSMA PET/CT is a valuable tool for the detection of PC local recurrence or extraprostatic metastases following rising PSA levels after primary definitive therapy and should be incorporated during routine work-up. Copyright © 2018. Published by Elsevier Inc.
Directory of Open Access Journals (Sweden)
Adelaide José Vaz
1996-12-01
Full Text Available A dot-ELISA was developed for the detection of antibodies in CSF in the immunologic diagnosis of human neurocysticercosis, using antigen extracts of the membrane and scolex of Cysticercus cellulosae (M+S-Cc and, alternately, membrane (M and vesicular fluid (VF of Cysticercus longicollis (Cl covalently bound to a new solid phase consisting of polyester fabric treated with N-methylol-acrylamide resin (dot-RT. The test was performed at room temperature, with reduced incubation times and with no need for special care in the manipulation of the support. The sensitivity rates obtained were 95.1% for antigen Cc and 97.6% for antigen Cl. Specificity was 90.6% when Cc was used, and 96.9% and 100% when M-Cl and VF-Cl were used, respectively. No significant differences in titer were observed between tests carried out with homologous and heterologous antigens. The low cost and easy execution of the dot-RT test using antigen extracts of Cysticercus longicollis indicate the test for use in the immunodiagnosis of human neurocysticercosis.Foi desenvolvido o teste dot-ELISA para detecção de anticorpos em líquido cefalorraquiano (LCR no diagnóstico imunológico da neurocisticercose humana, utilizando antígenos de membrana e escólex de Cysticercus cellulosae (M+E-Cc e, alternativamente, membrana (M e líquido vesicular (LV de Cysticercus longicollis (Cl covalentemente ligados a um novo suporte constituído de tecido de poliéster-resina de N-metilol-acrilamida (dot-TR. O teste foi realizado à temperatura ambiente, com tempos de incubação reduzidos e sem necessidade de cuidados na manipulação do suporte. A sensibilidade obtida foi de 95,1% para o antígeno Cc e 97,6% para o Cl. A especificidade foi de 90,6% quando o antígeno Cc foi usado, e 96,9% e 100% para M-Cl e LV-Cl, respectivamente. Não foi observada diferença significativa entre os antígenos homólogo e heterólogo. O baixo custo e a fácil execução do teste dot-TR empregando extratos antig
Serum Autoantibody Measurement for the Detection of Hepatocellular Carcinoma
Middleton, Catrin H.; Irving, William; Robertson, John F. R.; Murray, Andrea; Parsy-Kowalska, Celine B.; Macdonald, Isabel K.; McElveen, Jane; Allen, Jared; Healey, Graham F.; Thomson, Brian J.; Ryder, Stephen J.; Holdenrieder, Stefan; Chapman, Caroline J.
2014-01-01
Background Individuals with liver disease, and especially those with Hepatitis B or C, are at an increased risk of developing hepatocellular carcinoma (HCC) which is the third most common cause of cancer-related death worldwide. Inadequate screening tests largely account for presentation of advanced tumours and high mortality rates. Early detection of HCC amongst high-risk groups is paramount in improving prognosis. This research aimed to further characterise the previously described humoral immune response raised to tumour-associated antigens (TAAs) in the serum of patients with HCC. Methods Serum from 96 patients with confirmed HCC, 96 healthy controls matched for age and sex, 78 patients with confirmed liver cirrhosis and 91 patients with confirmed chronic liver disease were analysed for the presence of IgG autoantibodies raised to 41 recombinant TAAs/antigen fragments by ELISA. Results Varying autoantibody specificities (97–100%) and sensitivities (0–10%) were observed to individual TAAs. A 21-antigen panel achieved a specificity of 92% and sensitivity of 45% for the detection of HCC. This same panel identified 21% of 169 high-risk controls as having elevated autoantibody levels. A reproducible panel of 10 antigens achieved a specificity of 91% and sensitivity of 41% in HCC. 15% of 152 high-risk controls gave positive results with this panel. Conclusions This minimally invasive blood test has the potential to offer advantages over currently available tools for the identification of HCC amongst pre-disposed patients. Results are comparable to current gold standards in HCC (Ultrasonography) and to similar tests in other cancers (EarlyCDT-Lung). PMID:25093332
Serum autoantibody measurement for the detection of hepatocellular carcinoma.
Directory of Open Access Journals (Sweden)
Catrin H Middleton
Full Text Available BACKGROUND: Individuals with liver disease, and especially those with Hepatitis B or C, are at an increased risk of developing hepatocellular carcinoma (HCC which is the third most common cause of cancer-related death worldwide. Inadequate screening tests largely account for presentation of advanced tumours and high mortality rates. Early detection of HCC amongst high-risk groups is paramount in improving prognosis. This research aimed to further characterise the previously described humoral immune response raised to tumour-associated antigens (TAAs in the serum of patients with HCC. METHODS: Serum from 96 patients with confirmed HCC, 96 healthy controls matched for age and sex, 78 patients with confirmed liver cirrhosis and 91 patients with confirmed chronic liver disease were analysed for the presence of IgG autoantibodies raised to 41 recombinant TAAs/antigen fragments by ELISA. RESULTS: Varying autoantibody specificities (97-100% and sensitivities (0-10% were observed to individual TAAs. A 21-antigen panel achieved a specificity of 92% and sensitivity of 45% for the detection of HCC. This same panel identified 21% of 169 high-risk controls as having elevated autoantibody levels. A reproducible panel of 10 antigens achieved a specificity of 91% and sensitivity of 41% in HCC. 15% of 152 high-risk controls gave positive results with this panel. CONCLUSIONS: This minimally invasive blood test has the potential to offer advantages over currently available tools for the identification of HCC amongst pre-disposed patients. Results are comparable to current gold standards in HCC (Ultrasonography and to similar tests in other cancers (EarlyCDT-Lung.
Mshelbwala, P P; Ogunkoya, A B; Maikai, B V
2013-01-01
The study was carried out in eight dogs slaughtering outlets within four Local Government Areas of the State for the determination of rabies antigen in the saliva and brain of apparently healthy dogs slaughtered for human consumption. A total of one hundred (100) samples each of saliva and brain were collected before and after slaughter, respectively, between April to June, 2013, in the selected areas. The saliva was subjected to rapid immune-chromatographic test (RICT) while direct fluorescent antibody test (DFAT) was carried out on the brain samples. Structured questionnaire was administered to nineteen (19) dog meat processors comprising 18 males and 1 female in the selected areas. Sixty four percent of the samples tested were from female dogs while 36% were from males, 5% tested positive for rabies antigen with the use of both tests; there was no statistical association between sex and rabies status of the dogs sampled (P > 0.05). Butchers bitten during the course of slaughtering were 94.7% out of which 72.8% utilized traditional method of treatment and only 27.8% reported to the hospital for proper medical attention. This study has established the presence of rabies antigen in apparently healthy dogs in the study area.
Evaluation of an Antigen-Antibody “Combination” Enzyme Linked ...
African Journals Online (AJOL)
Conclusion: We conclude that although this assay depicts high sensitivity and specificity in detecting antibodies to HCV, it seems not to add further benefit in our study population to detect HCV infections by enhanced sensitivity due the potential contingency to trace viral capsid antigens. Keywords: Ag-Ab Combination assay ...
Energy Technology Data Exchange (ETDEWEB)
Prozorovskiy, S.V.; Alekseeva, N.V.; Knyazeva, E.N.; Ignatovich, V.F.; Barkhatova, O.T.
1984-02-01
A modification of an immunoradiometric analysis to determine Rickettsia antigens in various biological substrates was studied, using rickettsious diagnostricums, egg and cell cultures of Rickettsia. The method was highly sensitive for the determination of minimal quantities of antigens in these substrates. The method appears to be promising for studies related to the detection of microorganisms and their antigens. 5 references.