WorldWideScience

Sample records for antigen detection tests

  1. Antigen spot test (AST): a highly sensitive assay for the detection of antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Herbrink, P; van Bussel, F J; Warnaar, S O [Rijksuniversiteit Leiden (Netherlands)

    1982-02-12

    A method is described for detection of antibodies by means of nitrocellulose or diazobenzyloxymethyl (DBM) paper on which various antigens have been spotted. The sensitivity of this antigen spot test (AST) is comparable with that of RIA and ELISA. The method requires only nanogram amounts of antigen. Since a variety of antigens can be spotted on a single piece of nitrocellulose or DBM paper, this antigen spot test is especially useful for specificity controls on antibodies.

  2. KAtex antigen-detection test as a diagnostic tool for latent visceral ...

    African Journals Online (AJOL)

    SERVER

    2008-04-03

    Apr 3, 2008 ... Urine samples were tested by kAtex kit to detect VL antigen. All sera .... IFA, and ELISA-IgG and IgM) to finding of agreement and validity and reliability .... Animal inoculation is not usually employed as a diag- nostic test, since ...

  3. Isocyanate test antigens

    International Nuclear Information System (INIS)

    Karol, M.H.; Alarie, Y.C.

    1980-01-01

    A test antigen for detecting antibodies to a diisocyanate comprises the reaction product of a protein and a monoisocyanate derived from the same radical as the diisocyanate. The diisocyanates most usually encountered and therefore calling for antibody detection are those of toluene, hexamethylene, methylene, isophorone and naphthylene. The preferred protein is human serum albumin. (author)

  4. Detection of antigens of allergic diseases in children by radioallergosorbent test (RAST), 1

    International Nuclear Information System (INIS)

    Hirooka, Junko

    1977-01-01

    Detection of antigens mainly by RAST, measurement of immunoglobulin, and investigation of clinical history were performed on children with intractable bronchial asthma. The results were compared with those in cases of mild or moderate degree, and they were discussed. The obtained results were as follows: 1) Cases, of which the occurrence age of disease was under 2 years old, hold a majority in intractable cases, and the ratio was twice that of the control group. 2) A result of skin test was generally lower positive rate in the intractable group as compared to the control group. However, a result of prick test for buckwheat antigen in the intractable group showed higher positive rate than that in the control group. The intractable group tended to be separated into two extreme groups, one which showed positive to most of inhaled antigens in skin test, and another which showed negative to all antigens. 3) As a result of RAST, 13% of the intractable group showed positive to egg white out of food antigens, and it was three times the ratio of positive in the control group. One case showed strong positive to rice. 4) Two thirds of cases which showed positive in RAST for food antigens showed negative in prick test. 5) Total IgE in the serum of the intractable group was clearly lower in values than that of the control group. (Tsunoda, M.)

  5. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  6. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  7. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    International Nuclear Information System (INIS)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-01-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation

  8. Comparison between an immunochromatographic test with an amplified ELISA for detecting e antigen and anti-e antigen antibodies in chronic Hepatitis B

    International Nuclear Information System (INIS)

    Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Aguilar Rubido; Julio C

    2009-01-01

    The disappearance of the e antigen and the appearance of anti-e antigen antibodies are two biomarkers that indicate favorable prognosis in Hepatitis B. In this study the Advanced QualityTM immunochromatographic test for detecting those biomarkers was compared to the Vidas semi-quantitative ELISA test. Our hypothesis was that it is possible to use these biomarkers measured in a rapid and simple Advanced QualityTM immunochromatographic test for evaluating the therapeutic response in clinical trials with chronic hepatitis B patients. The two methods were done following the manufacturer's instructions. The sera were taken from 69 patients with chronic hepatitis B of the clinical trial of the CIGB 440 therapeutic candidate. The immunochromatographic test and ELISA for detecting e antigen and anti-e antigen antibodies presented from substantial to almost perfect agreement in the evaluation of the sera of chronic Hepatitis B patients in a clinical trial. The immunochromatographic test for detecting e antigen had a low positive average agreement and a high negative average agreement compared to the ELISA. Nevertheless, the immunochromatographic test for detecting anti-e antigen antibodies had a high negative and positive average agreement in comparison to the ELISA. The immunochromagraphic test for the e antigen had a lower positive average agreement compared to the ELISA and some patients infected with Hepatitis B virus could not be detected by the former assay. The immunochromatographic test for anti-e antigen antibodies showed a similar performance to that of ELISA and could therefore be used in clinical trials for chronic Hepatitis B in health institutions without the need of a highly qualified lab technician. (author)

  9. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Full Text Available Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Resumo: Objetivo: Avaliar o teste QuickVue® RSV Test Kit (QUIDEL Corp, CA, EUA para o diagn

  10. Antigen detection systems

    Science.gov (United States)

    Infectious agents or their constituent parts (antigens or nucleic acids) can be detected in fresh, frozen, or fixed tissues or other specimens, using a variety of direct or indirect assays. The assays can be modified to yield the greatest sensitivity and specificity but in most cases a particular m...

  11. Impact of the rapid antigen detection test in diagnosis and treatment of acute pharyngotonsillitis in a pediatric emergency room.

    Science.gov (United States)

    Cardoso, Débora Morais; Gilio, Alfredo Elias; Hsin, Shieh Huei; Machado, Beatriz Marcondes; de Paulis, Milena; Lotufo, João Paulo B; Martinez, Marina Baquerizo; Grisi, Sandra Josefina E

    2013-01-01

    To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.

  12. Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia.

    Science.gov (United States)

    Rahmadane, Ibnu; Certoma, Andrea F; Peck, Grantley R; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P; Bingham, John; Gardner, Ian A; Allen, John D

    2017-11-01

    Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0

  13. Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia.

    Directory of Open Access Journals (Sweden)

    Ibnu Rahmadane

    2017-11-01

    Full Text Available Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT, which is considered the reference (gold standard test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST. This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST

  14. Antigen detection of rabies virus in brain smear using direct Rapid Immunohistochemistry Test

    Directory of Open Access Journals (Sweden)

    Damayanti R

    2014-03-01

    Full Text Available Rabies is zoonotic disease caused by a fatal, neurotropic virus. Rabies virus is classified into the Genus of Lyssavirus under the yang family of Rhabdoviridae. Rabies affecting hot- blooded animals, as well as human. Dogs, cats, monkeys are the vectors or reservoirs for rabies and the virus was transmitted through the saliva after infected animal’s bites. The aim of this study was to conduct rapid diagnosis to detect rabies viral antigen in brain smear using immunohistochemical (IHC method namely direct Rapid Immunohistochemical Test (dRIT. A total number of 119 brain samples were achieved from Bukittinggi Veterinary Laboratory, West Sumatra. Standardisation and validation of the method were compared to Fluorescent Antibody Test (FAT as a golden standard for rabies diagnosis. Results show that dRIT was a very good method, it can be performed within two hours without the need of fluorescent microscope. The samples were tested using FAT and from 119 samples tested, 80 (67.23% samples were positive for rabies and 39 (32.77% samples were negative for rabies whereas using dRIT showed that 78 (65.54% samples were positive for rabies and 41 (34.45% samples were negative for rabies. The dRIT results were validated by comparing them with FAT results as a golden standard for rabies. The relative sensitivity of dRIT to FAT was 97.5% and the relative specificity to FAT was 100% (with Kappa value of 0.976, stated as excellent. The achievement showed that dRIT is very potential diagnostic tool and is highly recommended to be used widely as a rapid diagnosis tool for rabies.

  15. Detection and monitoring of human bocavirus 1 infection by a new rapid antigen test

    Directory of Open Access Journals (Sweden)

    A.H.L. Bruning

    2016-05-01

    Full Text Available Clinically relevant diagnosis of human bocavirus 1 (HBoV1 is challenging, as the virus is frequently detected in asymptomatic patients, and cofindings with other respiratory viruses are common. The clinical value of current diagnostic methods, such as PCR, is therefore low, and alternative diagnostic strategies are needed. We describe for the first time the use of an antigen detection assay for the rapid identification of HBoV1 in a paediatric patient with respiratory tract infection symptoms. We estimate the duration of active HBoV1 infection to be 6 days.

  16. Evaluating the use of dedicated swab for rapid antigen detection ...

    African Journals Online (AJOL)

    Evaluating the use of dedicated swab for rapid antigen detection testing in group a ... African Journal of Clinical and Experimental Microbiology ... Several generations of rapid antigen detection tests (RADTs) have been developed to facilitate ...

  17. Optimization of Diagnostic Elisa - Based Tests for the Detection of Auto-Antibodies Against Tumor Antigens in Human Serum

    Directory of Open Access Journals (Sweden)

    Daria Štefatić

    2008-08-01

    Full Text Available Colorectal cancer is one of the most common cancer types worldwide and it continues to be a serious public health problem. Early detection and diagnosis are of great importance in cancer management. At present, diagnostic blood tests are based on the detection of tumor-associated markers such as carcinoembryonic antigen (CEA, the cancer antigen CA19-9 for gastrointestinal cancer, CA15-3 for breast cancer or CA125 for ovarian cancer. The lack of sensitivity and specificity of these markers prevents their general use in cancer screening of an average risk population. Therefore, new cancer biomarkers or better screening methods are necessary to improve the diagnostics of the disease. This study was directed to the optimization of a diagnostic, enzyme linked immunosorbent assay (ELISA based test to identify and validate new serum markers, such as extracellular Protein Kinase A (ecPKA and Nicotinamide A-Meth- yltransferase (NNMT. In this type of assay, the cancer antigens are quantified indirectly - by detecting the presence of auto-antibodies against tumor proteins in human serum. The result of the optimization and validation process was in the case of ecPKA a reproducible and stable assay. In case of NNMT the assay was probably not sensitive enough.

  18. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  19. Prostate-Specific Antigen (PSA) Test

    Science.gov (United States)

    ... Cancer Prostate Cancer Screening Research Prostate-Specific Antigen (PSA) Test On This Page What is the PSA ... parts of the body before being detected. The PSA test may give false-positive or false-negative ...

  20. Development of a immunochromatographic test with avidin-biotin for the detection of antibodies against antigen e of hepatitis B in human plasma

    International Nuclear Information System (INIS)

    Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Diaz Argudin, Tamara

    2007-01-01

    The disappearance of antigen e of hepatitis B in the presence of the plasmatic antibodies against antigen e may indicate a satisfactory therapeutic response in patients with chronic hepatitis B. The immuno-chromatographic test carried out in the diagnosis of diseases use different antibody combinations and may employ the avidin or streptavidin-biotin technology to develop a rapid immuno-chromatographic test for the detection of antibodies anti-antigen e in the plasma. They were detected in the laboratory by means of two fast immuno-chromatographic tests when using in one of them the avidin-biotin technology. These tests are carried out with a one-step competitive inhibition format and amplified or not with avidin-biotin. Monoclonal antibodies against antigen e obtained by cellular hybridization were used. Forty-six plasmatic samples classified as positive and negative to the anti-antigen antibodies were evaluated with a reference immunochromatographic test Advanced QualityTM. The possible expiry time of the biological reagents forming part of these tests were studied with accelerated thermal-stability experiments. The possible interference in the plasma of some of the biochemical compounds used in these trials was analyzed. Four murine monoclonal antibodies anti-antigen e were obtained and only one of them was used in these immunochromatographic tests with an anti-antigen polyclonal antibody conjugated with gold. Both tests and their stable biological reagents discriminated the positive and negative samples to the antibodies anti-antigen e, as well as the commercial test. There was no interference in the biochemical compounds studied in these tests. Both immuno-chromatographic tests made in the laboratory are useful to detect antibodies anti-antigen e in the plasma. The avidin-biotin increased the analytical sensitivity of this type of fast immuno-chromatographic test without altering its performance features. (Author)

  1. [Diagnostic advantages of the test system "DS-EIA-HBsAg-0.01" for detection of HBV surface antigen].

    Science.gov (United States)

    Egorova, N I; Pyrenkova, I Iu; Igolkina, S N; Sharipova, I N; Puzyrev, V F; Obriadina, A P; Burkov, A N; Kornienko, N V; Fields, H A; Korovkin, A S; Shalunova, N V; Bektemirov, T A; Kuznetsov, K V; Koshcheeva, N A; Ulanova, T I

    2009-01-01

    The new highly sensitive test system "DS-EIA-HBsAg-0.01" (Priority Certificate No. 2006129019 of August 10, 2006) in detecting hepatitis B surface antigen (HBsAg) was assessed. The sensitivity of the test was estimated using the federal standards sample HBsAg 42-28-311-06, panels' samples Boston Biomedica Inc. (West Bridgewater, Mass, USA) and ZeptoMetrix Corp. (Buffalo, NY, USA). The findings have indicated that "DS-EIA-HBsAg-0.01" is equally effective in detecting different subtypes of HBsAg during a seroconversion period earlier than alternative assays. Along with its high analytical and diagnostic sensitivity, the system shows a high diagnostic specificity.

  2. A simple and inexpensive point-of-care test for hepatitis B surface antigen detection: serological and molecular evaluation.

    Science.gov (United States)

    Gish, R G; Gutierrez, J A; Navarro-Cazarez, N; Giang, K; Adler, D; Tran, B; Locarnini, S; Hammond, R; Bowden, S

    2014-12-01

    Early identification of chronic hepatitis B is important for optimal disease management and prevention of transmission. Cost and lack of access to commercial hepatitis B surface antigen (HBsAg) immunoassays can compromise the effectiveness of HBV screening in resource-limited settings and among marginalized populations. High-quality point-of-care (POC) testing may improve HBV diagnosis in these situations. Currently available POC HBsAg assays are often limited in sensitivity. We evaluated the NanoSign(®) HBs POC chromatographic immunoassay for its ability to detect HBsAg of different genotypes and with substitutions in the 'a' determinant. Thirty-seven serum samples from patients with HBV infection, covering HBV genotypes A-G, were assessed for HBsAg titre with the Roche Elecsys HBsAg II quantification assay and with the POC assay. The POC assay reliably detected HBsAg at a concentration of at least 50 IU/mL for all genotypes, and at lower concentrations for some genotypes. Eight samples with substitutions in the HBV 'a' determinant were reliably detected after a 1/100 dilution. The POC strips were used to screen serum samples from 297 individuals at risk for HBV in local clinical settings (health fairs and outreach events) in parallel with commercial laboratory HBsAg testing (Quest Diagnostics EIA). POC testing was 73.7% sensitive and 97.8% specific for detection of HBsAg. Although the POC test demonstrated high sensitivity over a range of genotypes, false negatives were frequent in a clinical setting. Nevertheless, the POC assay offers advantages for testing in both developed and resource-limited countries due to its low cost (0.50$) and immediately available results. © 2014 John Wiley & Sons Ltd.

  3. Evaluation of a rapid immunochromatographic ODK-0901 test for detection of pneumococcal antigen in middle ear fluids and nasopharyngeal secretions.

    Directory of Open Access Journals (Sweden)

    Muneki Hotomi

    Full Text Available Since the incidence of penicillin-resistant Streptococcus pneumoniae has been increasing at an astonishing rate throughout the world, the need for accurate and rapid identification of pneumococci has become increasingly important to determine the appropriate antimicrobial treatment. We have evaluated an immunochromatographic test (ODK-0901 that detects pneumococcal antigens using 264 middle ear fluids (MEFs and 268 nasopharyngeal secretions (NPSs. A sample was defined to contain S. pneumoniae when optochin and bile sensitive alpha hemolytic streptococcal colonies were isolated by culture. The sensitivity and specificity of the ODK-0901 test were 81.4% and 80.5%, respectively, for MEFs from patients with acute otitis media (AOM. In addition, the sensitivity and specificity were 75.2% and 88.8%, respectively, for NPSs from patients with acute rhinosinusitis. The ODK-0901 test may provide a rapid and highly sensitive evaluation of the presence of S. pneumoniae and thus may be a promising method of identifying pneumococci in MEFs and NPSs.

  4. CEA (Carcinoembryonic Antigen) Test

    Science.gov (United States)

    ... Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma-carboxy prothrombin (DCP) DHEAS ... Glance Why Get Tested? Primarily to monitor cancer treatment, including response to therapy and recurrence; as an ...

  5. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Science.gov (United States)

    Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P

    2016-01-01

    The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; ppoor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.

  6. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Directory of Open Access Journals (Sweden)

    Susheela D Biranjia-Hurdoyal

    Full Text Available The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit.Stool and blood samples were collected from 162 apparently healthy participants (control and 60 Type 2 diabetes mellitus (T2DM patients.The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%, followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%. The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value.The performances of the detection kits were affected by various factors which should be taken into consideration.

  7. Bedside diagnosis of imported malaria using the Binax Now malaria antigen detection test

    DEFF Research Database (Denmark)

    Wiese, Lothar; Bruun, Brita; Baek, Leif

    2006-01-01

    Malaria may be misdiagnosed in non-endemic countries when the necessary experience for rapid expert microscopy is lacking. Rapid diagnostic tests may improve the diagnosis and may play a role as a bedside diagnostic tool. In a multicentre study we recruited patients suspected of malaria over...... a period of 14 months. The Binax Now Malaria rapid test was used at the bedside and in the clinical microbiology laboratory. The training of clinical staff was monitored and their experience with the use of the test was recorded. 542 patients were included, 80 of whom had malaria diagnosed by microscopy...... be useful for the diagnosis of P. falciparum malaria when used by routine laboratory staff, but could lead to misdiagnoses when used at the bedside. Microscopy is still essential in order to identify the few missed diagnoses, to determine the degree of parasitaemia, and to ensure species diagnosis...

  8. DETECTION OF RABIES VIRAL ANTIGEN IN CATTLE BY RAPID IMMUNOCHROMTOGRAPHIC DIAGNOSTIC TEST

    Directory of Open Access Journals (Sweden)

    Santanu Panda

    2016-06-01

    Full Text Available In recent years, improved quality, accuracy and speed for diagnosis of rabies has been adopted for rabies control strategies in developing countries. In field condition, rapid immunochromtographic diagnostic test (RIDT is a true requirement for rapid epidemiological surveillance of rabies. In the present study, a total of ten numbers of rabies suspected cattle brain sample form different parts of West Bengal, India were examined through RIDT. The results revealed that one sample was found to be positive. The test was established as powerful screening tool for rabies with high sensitivity and specificity. Thus, RIDT can be employed as a reliable and quick approach for diagnosis and control of rabies under field condition.

  9. Evaluation of twenty rapid antigen tests for the detection of human influenza A H5N1, H3N2, H1N1, and B viruses.

    Science.gov (United States)

    Taylor, Janette; McPhie, Kenneth; Druce, Julian; Birch, Chris; Dwyer, Dominic E

    2009-11-01

    Twenty rapid antigen assays were compared for their ability to detect influenza using dilutions of virus culture supernatants from human isolates of influenza A H5N1 (clade 1 and 2 strains), H3N2 and H1N1 viruses, and influenza B. There was variation amongst the rapid antigen assays in their ability to detect different influenza viruses. Six of the 12 assays labeled as distinguishing between influenza A and B had comparable analytical sensitivities for detecting both influenza A H5N1 strains, although their ability to detect influenza A H3N2 and H1N1 strains varied. The two assays claiming H5 specificity did not detect either influenza A H5N1 strains, and the two avian influenza-specific assays detected influenza A H5N1, but missed some influenza A H3N2 virus supernatants. Clinical trials of rapid antigen tests for influenza A H5N1 are limited. For use in a pandemic where novel influenza strains are circulating (such as the current novel influenza A H1N1 09 virus), rapid antigen tests should ideally have comparable sensitivity and specificity for the new strains as for co-circulating seasonal influenza strains.

  10. Comparison of two solid-phase radioimmunoassay systems and a reverse passive haemagglutination test for the detection of hepatitis B surface antigen

    International Nuclear Information System (INIS)

    Hui, Z.; Coulepis, A.G.; Gust, I.D.

    1982-01-01

    The sensitivity and specificity of two commercially available radioimmunosay tests (Austria II-125, Abbott Laboratories; and International CIS, Commissariat Alenergie Atomique-Oris Laboratoire des Produits Biomedicaux) and a reverse passive haemagglutination test (Hepatest, Wellcome) for detection of hepatitis B surface antigen were evaluated using the Australian hepatitis B reference panel of 25 sera, and a panel of 257 sera collected from patients with acute hepatitis B, chronic carriers of hepatitis B surface antigen and two populations in which hepatitis B virus infection is known to be endemic. The three techniques were found to be generally comparable in sensitivity and specificity. The advantages and disadvantages of each method are discussed

  11. [Use of Rapid Antigen Detection Test (RADT) among general practitioner teachers at the Paris Descartes University: 2005-2007].

    Science.gov (United States)

    Cornaglia, C; Robinet, J; Partouche, H

    2009-06-01

    The distribution of the Rapid Antigen Detection Test (RADT) and the National Health Insurance's information campaign should efficiently reduce the unjustified use antibiotic. However, a preliminary survey among GP trainers at the Paris Descartes University indicated that the RADT was seldom used. This study had for aim to describe the RADT use trend among trainers since 2005 and the main obstacles to its widespread use, and to assess the Mac Isaac score use and antibiotic prescriptions. Between February and May 2007, a survey was carried out among 66 GPs who were required to report their first ten patients over three years of age presenting with pharyngitis. RADT use and antibiotic prescriptions were compared with those of the 2005 survey. RADT use had decreased (52.5% [48.2-56.8] versus 57.5% [52.1-68.8], p<0.05). GPs did not use the RADT because they considered it "useless in decision making". Clinical findings were sufficient in most cases. The Mac Isaac score was not widely used by GPs (28.3%) and antibiotic prescription had increased except for macrolides which had decreased (10% vs 15%). Among patients with a negative RADT, 11.9% (vs 10.5% en 2005, p<0.001) were prescribed antibiotics. The RADT use decreased in two years among GP trainers. GPs still prescribe treatment according to clinical findings, most without using diagnostic tools.

  12. Diagnostic accuracy of tests to detect hepatitis B surface antigen: a systematic review of the literature and meta-analysis

    Directory of Open Access Journals (Sweden)

    Ali Amini

    2017-11-01

    Full Text Available Abstract Background Chronic Hepatitis B Virus (HBV infection is characterised by the persistence of hepatitis B surface antigen (HBsAg. Expanding HBV diagnosis and treatment programmes into low resource settings will require high quality but inexpensive rapid diagnostic tests (RDTs in addition to laboratory-based enzyme immunoassays (EIAs to detect HBsAg. The purpose of this review is to assess the clinical accuracy of available diagnostic tests to detect HBsAg to inform recommendations on testing strategies in 2017 WHO hepatitis testing guidelines. Methods The systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA guidelines using 9 databases. Two reviewers independently extracted data according to a pre-specified plan and evaluated study quality. Meta-analysis was performed. HBsAg diagnostic accuracy of rapid diagnostic tests (RDTs was compared to enzyme immunoassay (EIA and nucleic-acid test (NAT reference standards. Subanalyses were performed to determine accuracy among brands, HIV-status and specimen type. Results Of the 40 studies that met the inclusion criteria, 33 compared RDTs and/or EIAs against EIAs and 7 against NATs as reference standards. Thirty studies assessed diagnostic accuracy of 33 brands of RDTs in 23,716 individuals from 23 countries using EIA as the reference standard. The pooled sensitivity and specificity were 90.0% (95% CI: 89.1, 90.8 and 99.5% (95% CI: 99.4, 99.5 respectively, but accuracy varied widely among brands. Accuracy did not differ significantly whether serum, plasma, venous or capillary whole blood was used. Pooled sensitivity of RDTs in 5 studies of HIV-positive persons was lower at 72.3% (95% CI: 67.9, 76.4 compared to that in HIV-negative persons, but specificity remained high. Five studies evaluated 8 EIAs against a chemiluminescence immunoassay reference standard with a pooled sensitivity and specificity of 88.9% (95% CI: 87.0, 90.6 and

  13. Detection of cell-associated or soluble antigens of Legionella pneumophila serogroups 1 to 6, Legionella bozemanii, Legionella dumoffii, Legionella gormanii, and Legionella micdadei by staphylococcal coagglutination tests.

    OpenAIRE

    Wilkinson, H W; Fikes, B J

    1981-01-01

    Current methods used for the detection of whole-cell isolates of Legionella or for the detection of Legionella soluble antigens are technically impractical for many clinical laboratories. The purpose of this study was to explore practical alternatives. The results showed that whole cell isolates of Legionella pneumophila serogroups 1 to 6, Legionella bozemanii, Legionella dumoffii, Legionella gormanii, and Legionella micdadei were identified specifically by a simple slide agglutination test o...

  14. Polyclonal antibodies for the detection of Trypanosoma cruzi circulating antigens.

    Directory of Open Access Journals (Sweden)

    Edith S Málaga-Machaca

    2017-11-01

    Full Text Available Detection of Trypanosoma cruzi antigens in clinical samples is considered an important diagnostic tool for Chagas disease. The production and use of polyclonal antibodies may contribute to an increase in the sensitivity of immunodiagnosis of Chagas disease.Polyclonal antibodies were raised in alpacas, rabbits, and hens immunized with trypomastigote excreted-secreted antigen, membrane proteins, trypomastigote lysate antigen and recombinant 1F8 to produce polyclonal antibodies. Western blot analysis was performed to determine specificity of the developed antibodies. An antigen capture ELISA of circulating antigens in serum, plasma and urine samples was developed using IgY polyclonal antibodies against T. cruzi membrane antigens (capture antibody and IgG from alpaca raised against TESA. A total of 33 serum, 23 plasma and 9 urine samples were analyzed using the developed test. Among serum samples, compared to serology, the antigen capture ELISA tested positive in 55% of samples. All plasma samples from serology positive subjects were positive in the antigen capture ELISA. All urine positive samples had corresponding plasma samples that were also positive when tested by the antigen capture ELISA.Polyclonal antibodies are useful for detection of circulating antigens in both the plasma and urine of infected individuals. Detection of antigens is direct evidence of the presence of the parasite, and could be a better surrogate of current infection status.

  15. Clinical score and rapid antigen detection test to guide antibiotic use for sore throats: randomised controlled trial of PRISM (primary care streptococcal management).

    Science.gov (United States)

    Little, Paul; Hobbs, F D Richard; Moore, Michael; Mant, David; Williamson, Ian; McNulty, Cliodna; Cheng, Ying Edith; Leydon, Geraldine; McManus, Richard; Kelly, Joanne; Barnett, Jane; Glasziou, Paul; Mullee, Mark

    2013-10-10

    To determine the effect of clinical scores that predict streptococcal infection or rapid streptococcal antigen detection tests compared with delayed antibiotic prescribing. Open adaptive pragmatic parallel group randomised controlled trial. Primary care in United Kingdom. Patients aged ≥ 3 with acute sore throat. An internet programme randomised patients to targeted antibiotic use according to: delayed antibiotics (the comparator group for analyses), clinical score, or antigen test used according to clinical score. During the trial a preliminary streptococcal score (score 1, n=1129) was replaced by a more consistent score (score 2, n=631; features: fever during previous 24 hours; purulence; attends rapidly (within three days after onset of symptoms); inflamed tonsils; no cough/coryza (acronym FeverPAIN). Symptom severity reported by patients on a 7 point Likert scale (mean severity of sore throat/difficulty swallowing for days two to four after the consultation (primary outcome)), duration of symptoms, use of antibiotics. For score 1 there were no significant differences between groups. For score 2, symptom severity was documented in 80% (168/207 (81%) in delayed antibiotics group; 168/211 (80%) in clinical score group; 166/213 (78%) in antigen test group). Reported severity of symptoms was lower in the clinical score group (-0.33, 95% confidence interval -0.64 to -0.02; P=0.04), equivalent to one in three rating sore throat a slight versus moderate problem, with a similar reduction for the antigen test group (-0.30, -0.61 to -0.00; P=0.05). Symptoms rated moderately bad or worse resolved significantly faster in the clinical score group (hazard ratio 1.30, 95% confidence interval 1.03 to 1.63) but not the antigen test group (1.11, 0.88 to 1.40). In the delayed antibiotics group, 75/164 (46%) used antibiotics. Use of antibiotics in the clinical score group (60/161) was 29% lower (adjusted risk ratio 0.71, 95% confidence interval 0.50 to 0.95; P=0.02) and in the

  16. Histoplasma Urinary Antigen Testing Obviates the Need for Coincident Serum Antigen Testing.

    Science.gov (United States)

    Libert, Diane; Procop, Gary W; Ansari, Mohammad Q

    2018-03-07

    Serum and urine antigen (SAg, UAg) detection are common tests for Histoplasma capsulatum. UAg detection is more widely used and reportedly has a higher sensitivity. We investigated whether SAg detection contributes meaningfully to the initial evaluation of patients with suspected histoplasmosis. We reviewed 20,285 UAg and 1,426 SAg tests ordered from 1997 to 2016 and analyzed paired UAg and SAg tests completed on the same patient within 1 week. We determined the positivity rate for each test. Of 601 paired specimens, 542 were concurrent negatives and 48 were concurrent positives (98% agreement). Medical records were available for eight of 11 pairs with discrepant results. UAg was falsely positive in six instances, truly positive once, and falsely negative once. These findings support using a single antigen detection test, rather than both UAg and SAg, as an initial screen for suspected histoplasmosis. This aligns with the current practice of most physicians.

  17. Detection of anti-dsDNA by IgG ELISA test using two different sources of antigens: calf thymus versus E.coli

    Directory of Open Access Journals (Sweden)

    Mohammadi M

    2009-04-01

    Full Text Available "nBackground: Anti-dsDNA antibodies frequently found in the sera Systemic Lupus Erythematosus patients, particularly in active disease stage. Nowadays exploit different eukaryotic and prokaryotic dsDNA as antigen source and different reagents as binder. The aim of this study to compared two dsDNA different sources and tow different kinds of reagents for binder in ELISA test. "nMethods: In this study bacterial genomic DNA from E.coli (ATCC 25922 and genomic DNA from calf thymus extracted with high purity and were used as antigens for IgG anti-dsDNA detection by ELISA. To coat dsDNA in microtiter wells, tow different kinds of reagents including methylated -BSA and poly-l-lysine (for pre-coating are used. Sera from systemic lupus erythematosus patients and from normal blood donors are used to assess sensitivity and specificity of our ELISA test in compared with IF test and commercial kits. "nResults: Our results displayed pre-coating of microtiter plates with methylated -BSA reduce nonspecific binding reaction and the relative sensitivity and specificity of ELISA increased when calf thymus DNA is employed as antigenic source in compared with IF test and commercial kits 80%, 88% and 100%, 98% respectively, but when E.coli DNA is used 73%, 69% and 85%, 79%, respectively. "nConclusion: The genomic DNA from calf thymus is a potentially useful source of antigen for detection of anti-dsDNA by ELISA. Also the use of methylatted- BSA could have an effective role in reducing of nonspecific binding reactions.

  18. Radioimmunoassay for the detection of Australia-SH antigen

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, H [Giessen Univ. (Germany, F.R.). Zentrum fuer Innere Medizin

    1974-06-01

    Among infectious diseases, hepatitis presents a great problem in all countries with a high medical standard. The number of Australia antigen-positive cases rises from year to year, due to the increase in drug-fixer hepatitis and blood transfusions. Highly sensitive and at the same time practicable methods are therefore required for the identification of Australia antigen carriers and their elimination as blood donors. The most sensitive of all currently used tests for the detection of Australia antigen is the 'solid phase' radioimmunoassay since it permits an objective and quantitative measurement of the antigen.

  19. Diagnostic performances of two rapid tests for detection of feline leukemia virus antigen in sera of experimentally feline leukemia virus-infected cats

    Directory of Open Access Journals (Sweden)

    Matthew R Krecic

    2017-12-01

    Full Text Available Objectives The objective of this study was to compare the diagnostic sensitivities and specificities of WITNESS FeLV-FIV (Zoetis and SNAP FIV/FeLV Combo Test (IDEXX for the detection of FeLV p27 antigen in the sera of experimentally feline leukemia virus (FeLV-infected cats. Methods Diagnostic sensitivities of WITNESS and SNAP were determined through testing of 47 serum samples collected from cats day 56 post-experimental infection with a virulent FeLV Rickard strain. Successful experimental infection was confirmed based on observation of FeLV antigen and proviral DNA in anti-coagulated (EDTA whole-blood samples by immunofluorescent antibody (IFA test and PCR, respectively. Diagnostic specificities of both tests were determined through testing of sera of 92 laboratory-housed, non-FeLV-exposed specific pathogen-free (SPF cats. Results Forty-one of 47 blood samples were IFA positive, whereas all 47 samples were PCR positive. All 92 non-FeLV-infected SPF cats were IFA and PCR negative. In comparison to IFA as the reference method, both WITNESS and SNAP tests yielded equivalent sensitivities and specificities of 100% and 97.8%, respectively. In comparison to PCR as the reference method, both WITNESS and SNAP tests likewise performed equivalently, with sensitivities and specificities of 91.5% and 100%, respectively. Conclusions and relevance Sensitivity and specificity of WITNESS FeLV-FIV for identifying FeLV p27 antigen in the sera of these experimentally FeLV-infected and non-FeLV-exposed SPF cats equaled those of the SNAP FIV/FeLV Combo Test. However, all positive results, regardless of the point-of-care test used, should be confirmed before making clinical decisions such as segregation from other cats or euthanasia.

  20. Immunodiagnosis of paracoccidioidomycosis due to Paracoccidioides brasiliensis using a latex test: detection of specific antibody anti-gp43 and specific antigen gp43.

    Directory of Open Access Journals (Sweden)

    Priscila Oliveira Dos Santos

    2015-02-01

    Full Text Available Paracoccidioidomycosis (PCM is a life-threatening systemic disease and is a neglected public health problem in many endemic regions of Latin America. Though several diagnostic methods are available, almost all of them present with some limitations.A latex immunoassay using sensitized latex particles (SLPs with gp43 antigen, the immunodominant antigen of Paracoccidioides brasiliensis, or the monoclonal antibody mAb17c (anti-gp43 was evaluated for antibody or antigen detection in sera, cerebrospinal fluid (CSF, and bronchoalveolar lavage (BAL from patients with PCM due to P. brasiliensis. The gp43-SLPs performed optimally to detect specific antibodies with high levels of sensitivity (98.46%, 95% CI 91.7-100.0, specificity (93.94%, 95% CI 87.3-97.7, and positive (91.4% and negative (98.9% predictive values. In addition, we propose the use of mAb17c-SLPs to detect circulating gp43, which would be particularly important in patients with immune deficiencies who fail to produce normal levels of immunoglobulins, achieving good levels of sensitivity (96.92%, 95% CI 89.3-99.6, specificity (88.89%, 95% CI 81.0-94.3, and positive (85.1% and negative (97.8% predictive values. Very good agreement between latex tests and double immune diffusion was observed for gp43-SLPs (k = 0.924 and mAb17c-SLPs (k = 0.850, which reinforces the usefulness of our tests for the rapid diagnosis of PCM in less than 10 minutes. Minor cross-reactivity occurred with sera from patients with other fungal infections. We successfully detected antigens and antibodies from CSF and BAL samples. In addition, the latex test was useful for monitoring PCM patients receiving therapy.The high diagnostic accuracy, low cost, reduced assay time, and simplicity of this new latex test offer the potential to be commercialized and makes it an attractive diagnostic assay for use not only in clinics and medical mycology laboratories, but mainly in remote locations with limited laboratory infrastructure

  1. Diagnostic utility of a direct immunofluorescence test to detect feline coronavirus antigen in macrophages in effusive feline infectious peritonitis.

    Science.gov (United States)

    Litster, A L; Pogranichniy, R; Lin, T-L

    2013-11-01

    The antemortem diagnosis of feline infectious peritonitis (FIP) remains challenging in clinical practice, since current testing methods have suboptimal diagnostic accuracy. Immunohistochemical testing of biopsy specimens and postmortem examination are the standard diagnostic methods, although direct immunofluorescence (DIF) testing to detect feline coronavirus in macrophages in effusion specimens has been reported to have 100% specificity and has been recommended as an antemortem confirmatory test. The aim of this study was to compare the results of DIF testing in antemortem feline effusions with postmortem results using field samples. Effusion specimens were collected antemortem from 17 cats and tested by DIF, followed by postmortem examination. Histopathological examination of specimens collected at postmortem confirmed FIP in 10/17 cases and ruled out FIP out in 7/17 cases. Antemortem DIF testing was positive in all 10 cases confirmed as FIP at postmortem examination. In the seven cats where FIP was ruled out at postmortem examination, DIF was negative in five cases and positive in the remaining two cases. The calculated sensitivity of DIF testing was 100% and the specificity was 71.4%. Duplicate effusion specimens from eight cats that were initially DIF positive were stored refrigerated (4 °C) or at room temperature (22-25 °C) and subjected to serial DIF testing to determine the duration of positive results. DIF-positive specimens stored at both temperatures retained their positive status for at least 2 days. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Prostatic specific antigen for prostate cancer detection

    Directory of Open Access Journals (Sweden)

    Lucas Nogueira

    2009-10-01

    Full Text Available Prostate-specific antigen (PSA has been used for prostate cancer detection since 1994. PSA testing has revolutionized our ability to diagnose, treat, and follow-up patients. In the last two decades, PSA screening has led to a substantial increase in the incidence of prostate cancer (PC. This increased detection caused the incidence of advanced-stage disease to decrease at a dramatic rate, and most newly diagnosed PC today are localized tumors with a high probability of cure. PSA screening is associated with a 75% reduction in the proportion of men who now present with metastatic disease and a 32.5% reduction in the age-adjusted prostate cancer mortality rate through 2003. Although PSA is not a perfect marker, PSA testing has limited specificity for prostate cancer detection, and its appropriate clinical application remains a topic of debate. Due to its widespread use and increased over-detection, the result has been the occurrence of over-treatment of indolent cancers. Accordingly, several variations as regards PSA measurement have emerged as useful adjuncts for prostate cancer screening. These procedures take into consideration additional factors, such as the proportion of different PSA isoforms (free PSA, complexed PSA, pro-PSA and B PSA, the prostate volume (PSA density, and the rate of change in PSA levels over time (PSA velocity or PSA doubling time. The history and evidence underlying each of these parameters are reviewed in the following article.

  3. Prostatic specific antigen for prostate cancer detection.

    Science.gov (United States)

    Nogueira, Lucas; Corradi, Renato; Eastham, James A

    2009-01-01

    Prostate-specific antigen (PSA) has been used for prostate cancer detection since 1994. PSA testing has revolutionized our ability to diagnose, treat, and follow-up patients. In the last two decades, PSA screening has led to a substantial increase in the incidence of prostate cancer (PC). This increased detection caused the incidence of advanced-stage disease to decrease at a dramatic rate, and most newly diagnosed PC today are localized tumors with a high probability of cure. PSA screening is associated with a 75% reduction in the proportion of men who now present with metastatic disease and a 32.5% reduction in the age-adjusted prostate cancer mortality rate through 2003. Although PSA is not a perfect marker, PSA testing has limited specificity for prostate cancer detection, and its appropriate clinical application remains a topic of debate. Due to its widespread use and increased over-detection, the result has been the occurrence of over-treatment of indolent cancers. Accordingly, several variations as regards PSA measurement have emerged as useful adjuncts for prostate cancer screening. These procedures take into consideration additional factors, such as the proportion of different PSA isoforms (free PSA, complexed PSA, pro-PSA and B PSA), the prostate volume (PSA density), and the rate of change in PSA levels over time (PSA velocity or PSA doubling time). The history and evidence underlying each of these parameters are reviewed in the following article.

  4. Evaluation of two new commercial tests for the diagnosis of acute dengue virus infection using NS1 antigen detection in human serum.

    Science.gov (United States)

    Dussart, Philippe; Petit, Laure; Labeau, Bhety; Bremand, Laetitia; Leduc, Alexandre; Moua, David; Matheus, Séverine; Baril, Laurence

    2008-08-20

    We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV) infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France), and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA), pan-E Dengue Early ELISA (Panbio - Brisbane, Australia)-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad). We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222) was 87.4% (95% confidence interval: 82.3% to 91.5%); that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4%) after 15 minutes and 82.4% (95% CI: 76.8% to 87.2%) after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%). The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8%) and a specificity of 97.9% (95% CI: 88.9% to 99.9%). Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.

  5. Evaluation of two new commercial tests for the diagnosis of acute dengue virus infection using NS1 antigen detection in human serum.

    Directory of Open Access Journals (Sweden)

    Philippe Dussart

    Full Text Available BACKGROUND: We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France, and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA, pan-E Dengue Early ELISA (Panbio - Brisbane, Australia-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad. METHODS: We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. RESULTS: The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222 was 87.4% (95% confidence interval: 82.3% to 91.5%; that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4% after 15 minutes and 82.4% (95% CI: 76.8% to 87.2% after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%. The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8% and a specificity of 97.9% (95% CI: 88.9% to 99.9%. CONCLUSION: Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.

  6. Validation of a urine circulating cathodic antigen cassette test for detection of Schistosoma haematobiumin uMkhanyakude district of South Africa.

    Science.gov (United States)

    Rubaba, O; Chimbari, M J; Soko, W; Manyangadze, T; Mukaratirwa, S

    2018-06-01

    Circulating cathodic antigen (CCA) tests for schistosomiasis are fast and less complicated allowing making them good candidates for routine qualitative screening for schistosomiasis at point of care. The urine-CCA has been evaluated for detection of S. mansoni with promising results. Its specificity and consistency in detecting S. haematobium infection in different endemic regions has been variable. This study validated a rapid urine-CCA cassette test for qualitative detection of S. haematobium infection in an S. haematobium endemic area with low S. mansoni prevalence. Microscopic examination for the standard urine filtration technique was used to validate the commercially available urine-CCA cassette test (rapid medical diagnostics ® ). The validation was done in a sample of primary school pupils (n = 420) aged 10-15 years in schools in the Jozini Municipality, KZN. There was a relationship between infection intensity and a positive urine-CCA test. Using the urine filtration method as the gold standard, the prevalence for S. haematobium was 40%, the accuracy of the CCA kit was 54.8%, sensitivity was 68.1% while the specificity was 45.8%. The positive predictive value was 45.82% while the negative predictive value was 68.05%. Both the urine filtration and the urine-CCA methods detected heavy (≥50 eggs/10 mL urine) and light infections at statistically significant levels. The overall accuracy, sensitivity and specificity of the urine-CCA cassette test were low. The urine-CCA cassette test performed much better for heavy infections than low infections (p < 0.05) implying that the kit may not be suitable for low endemic areas. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Detection of gonococcal antigens in urine by radioimmunoassay

    International Nuclear Information System (INIS)

    Thornley, M.J.; Wilson, D.V.; Hormaeche, R.D. de; Coombs, R.R.A.; Oates, J.K.

    1979-01-01

    A method of detecting gonococcal antigens by solid-phase radioimmunoassay with radioactively labelled antibody is described. A specificity test has been developed that enables this method to be used to detect gonococcal antigens in urine sediments. When sediments from samples of urine from male patients with gonorrhoea were tested, 31 (74%) of 42 gave positive results, clearly distinguishing them from sediments from urine samples from men with non-specific urethritis, none of which was positive. Ten of 14 urine sediments from urine samples from women with gonorrhoea gave positive results, as did 3 of 18 sediments from urine samples from women patients without gonorrhoea.These experiments demonstrate that gonococcal antigens can be detected in urine by radioimmunoassay; the method could be useful in diagnosis if, after refinement, its sensitivity and specificity were to be increased. (author)

  8. Evaluation of a rapid antigen detection test in the diagnosis of streptococcal pharyngitis in children and its impact on antibiotic prescription.

    Science.gov (United States)

    Maltezou, Helen C; Tsagris, Vasilios; Antoniadou, Anastasia; Galani, Labrini; Douros, Constantinos; Katsarolis, Ioannis; Maragos, Antonios; Raftopoulos, Vasilios; Biskini, Panagiota; Kanellakopoulou, Kyriaki; Fretzayas, Andreas; Papadimitriou, Theodoros; Nicolaidou, Polyxeni; Giamarellou, Helen

    2008-12-01

    To study the performance of the Becton-Dickinson Link 2 Strep A Rapid Test, a rapid antigen detection test (RADT) for diagnosing streptococcal pharyngitis in children presenting to private offices and to the Pediatric Outpatient Clinic of a university hospital, in relation to clinical criteria (fever, tender anterior cervical lymph nodes, tonsillar exudate and absence of cough), and its impact on antibiotic prescription. Children were enrolled in Group A (enrolment by private-practice paediatricians; diagnosis by clinical picture only), Group B (enrolment by private-practice paediatricians; diagnosis by RADT and culture) or Group C (enrolment by hospital-affiliated paediatricians in the Pediatric Outpatient Clinic; diagnosis by RADT and culture). During a 2 year period, 820 children were enrolled [369 (45%) in Group A, 270 (33%) in Group B and 181 (22%) in Group C]. Streptococcal pharyngitis was diagnosed by RADT and culture in 146 (32.4%) of the 451 tested children. The sensitivity, specificity and positive and negative predictive values of the RADT were 83.1%, 93.3%, 82.4% and 93.6%, respectively. A stepwise increase in the sensitivity of the RADT was noted among children with one, two, three or four clinical criteria (60.9% to 95.8%). Paediatricians without access to laboratory tests were more likely to prescribe antibiotics compared with paediatricians with access to tests (72.2% versus 28.2%, P antibiotics more frequently compared with hospital-affiliated paediatricians (55.7% versus 19.9%, P antibiotic administration. Such a strategy has an important impact on limiting throat culture testing and is associated with reduced antibiotic prescription.

  9. Utility of a stool antigen test to detect the incidence of helicobacter pylori infection and familial and community enviromental risk factors for this infection in pediatric age.

    Science.gov (United States)

    Sabbi, T; Dall'Oglio, L; De Angelis, P; Torroni, E; Colistro, F; Azzolina, M; Santoni, A; Di Ciommo, V; Benedetto, M

    2012-01-01

    Helicobacter pylori (Hp) infection is mainly acquired during childhood; it is recognised as a cause of gastritis and peptic ulcer and it has been classified as a group A carcinogen by World Health Organization. The exact mode of transmission is as yet, not known. Aim of our study has been to identify risk factors associated with Helicobacter pylori infection in a preschool and school population and to confirm if Hp antigen in faeces is useful as screening in epidemiological studies. We interviewed, with questionnaire, 400 children (203 male; age range 3-10 years; mean age 6 years) of 3 different schools and stool samples were collected of all children too. 35 of 400 (8%) children underwent to upper gastrointestinal endoscopy because of a suspect of upper gastrointestinal disease. stool were collected from 400 school children and 35 of them shown positivity of Hp antigen test. A questionnaire about presence of nausea, vomit, recurrent abdominal pain, family size, parent's occupations and education, use of antibiotics, country of birth of child and parents, personal hygiene, breast feeding, presence of the animals was completed. 35 children with positive Hp stool antigen test and a suspicious of upper gastrointestinal disease (recurrent abdominal pain, diurnal or nocturnal abdominal pain, nausea, vomiting, iron deficiency) underwent to esophagogastroduodenoscopy (EGDS) that demonstrated antral gastritis and positive histology and urease rapid test. the results of this study suggest that risk factors for Hp infection are low socioeconomics factors, hygiene and living conditions and that Hp antigen in faeces is useful as screening test.

  10. [Contribution of HCV core antigen testing in HCV diagnosis by test from the company Abbott Laboratories].

    Science.gov (United States)

    Trbusek, J

    2009-11-01

    Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.

  11. The Effect of Rapid Antigen Detection Test on Antibiotic Prescription Decision of Clinicians and Reducing Antibiotic Costs in Children with Acute Pharyngitis.

    Science.gov (United States)

    Kose, Engin; Sirin Kose, Seda; Akca, Deniz; Yildiz, Kerem; Elmas, Cengizhan; Baris, Mustafa; Anil, Murat

    2016-08-01

    We aimed to investigate the effect of rapid antigen detection test (RADT) in the diagnosis of streptococcal pharyngitis, its impact on antibiotic prescription decision of pediatricians and influence on reduction of antibiotic treatment costs in children with pharyngitis. The study group consisted of 223 patients who were diagnosed with pharyngitis by pediatricians. The sensitivity and specificity of RADT were 92.1% (95% Cl: 78.6-98.3%) and 97.3% (95% Cl: 93.8-99.1%), respectively. In the first assessment, before performing RADT, pediatricians decided to prescribe antibiotics for 178 (79.8%) patients with pharyngitis. After learning RADT results, pediatricians finally decided to prescribe antibiotics for 83 (37.2%) patients with pharyngitis, and antibiotic prescription decreased by 42.6%. Antibiotic costs in non-Group A streptococcus pharyngitis, Group A streptococcus pharyngitis and all subjects groups decreased by 80.8%, 48%, and 76.4%, respectively. Performing RADT in children with pharyngitis has an important impact on treatment decision of clinicians, reduction of unnecessary antibiotic prescriptions and antibiotic costs. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Test characteristics of two rapid antigen detection tests (SD FK50 and SD FK60 for the diagnosis of malaria in returned travellers

    Directory of Open Access Journals (Sweden)

    Van Esbroeck Marjan

    2009-05-01

    Full Text Available Abstract Background Two malaria rapid diagnostic tests were evaluated in a travel clinic setting: the SD FK50 Malaria Ag Plasmodium falciparum test (a two-band test and the SD FK60 Malaria Ag P. falciparum/Pan test (a three-band test. Methods A panel of stored whole blood samples (n = 452 and n = 614 for FK50 and FK60, respectively from returned travellers was used. The reference method was microscopy with PCR in case of discordant results. Results For both tests, overall sensitivity for the detection of P. falciparum was 93.5%, reaching 97.6% and 100% at parasite densities above 100 and 1,000/μl respectively. Overall sensitivities for Plasmodium vivax, Plasmodium ovale and Plasmodium malariae for the FK60 test were 87.5%, 76.3% and 45.2%, but they reached 92.6% and 90.5% for P. vivax and P. ovale at parasite densities above 500/μl. Specificities were above 95% for all species and both tests when corrected by PCR, with visible histidine-rich protein-2 lines for P. malariae (n = 3 and P. vivax and P. ovale (1 sample each. Line intensities were reproducible and correlated to parasite densities. The FK60 tests provided clues to estimate parasite densities for P. falciparum below or above 1,000/μl. Conclusion Both the FK50 and FK60 performed well for the diagnosis of P. falciparum in the present setting, and the FK60 for the diagnosis of P. vivax and P. ovale at parasite densities > 500/μl. The potential use of the FK60 as a semi-quantitative estimation of parasite density needs to be further explored.

  13. Utility of a stool antigen test to detect the incidence of helicobacter pylori infection and familial and community enviromental risk factors for this infection in pediatric age

    Directory of Open Access Journals (Sweden)

    T. Sabbi

    2012-04-01

    Full Text Available Background: helicobacter pylori (hp infection is mainly acquired during childhood; it is recognised as a cause of gastritis and peptic ulcer and it has been classified as a group A carcinogen by World health organization. the exact mode of transmission is as yet, not known. Aim of our study has been to identify risk factors associated with helicobacter pylori infection in a preschool and school population and to confirm if hp antigen in faeces is useful as screening in epidemiological studies. Methods: We interviewed, with questionnaire, 400 children (203 male; age range 3-10 years; mean age 6 years of 3 different schools and stool samples were collected of all children too. 35 of 400 (8% children underwent to upper gastrointestinal endoscopy because of a suspect of upper gastrointestinal disease. Results: stool were collected from 400 school children and 35 of them shown positivity of hp antigen test. A questionnaire about presence of nausea, vomit, recurrent abdominal pain, family size, parent’s occupations and education, use of antibiotics, country of birth of child and parents, personal hygiene, breast feeding, presence of the animals was completed. 35 children with positive hp stool antigen test and a suspicious of upper gastrointestinal disease (recurrent abdominal pain, diurnal or nocturnal abdominal pain, nausea, vomiting, iron deficiency underwent to esophagogastroduodenoscopy (egdS that demonstrated antral gastritis and positive histology and urease rapid test. Conclusions: the results of this study suggest that risk factors for hp infection are low socioeconomics factors, hygiene and living conditions and that hp antigen in faeces is useful as screening test.

  14. The hybrid EIA test: a specific and sensitive assay for the detection of woodchuck antibody to hepatitis surface antigen (anti-WHs).

    Science.gov (United States)

    Millman, I; Glass, R G

    1988-05-01

    'Ausria II' polystyrene beads (Abbott Labs, N. Chicago) are reacted with woodchuck serum positive for WHsAg in a dilution predetermined by titration. This modified bead is used in a blocking assay to detect the presence of antibody to the surface antigen of woodchuck hepatitis virus (anti-WHs). Serum containing woodchuck anti-WHs and commercial horseradish peroxidase (HRP) labeled anti-HBs are sequentially added. A drop in optical density at 492 nm of 50% or more due to the blocking of HRP conjugated anti-HBs by anti-WHs compared with a control (negative woodchuck serum) is a measure of anti-WHs. The ease and simplicity of converting readily available 'Ausria II' beads to specific reagents for detecting anti-WHs should be welcomed by investigators studying WHV. The method described is both sensitive and reproducible.

  15. Prostate-Specific Antigen (PSA) Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... medlineplus.gov/labtests/prostatespecificantigenpsatest.html Prostate-Specific Antigen (PSA) Test To use the sharing features on this ... enable JavaScript. What is a prostate-specific antigen (PSA) test? A prostate-specific antigen (PSA) test measures ...

  16. Fast and efficient detection of tuberculosis antigens using liposome encapsulated secretory proteins of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    Dileep Tiwari

    2017-04-01

    Conclusion: Our study demonstrated that the newly developed liposome tuberculosis antigen card test detected antigens in our study population with approximately 97.48% sensitivity and 95.79% specificity. This is the first study to report the liposomal encapsulation of culture filtrate proteins from M. tuberculosis for diagnostic application.

  17. DETECTION OF PNEUMOCOCCAL CAPSULAR ANTIGEN IN THE PRESENCE OF PENICILLIN IN-VITRO

    NARCIS (Netherlands)

    HOLLOWAY, Y; BOERSMA, WG; KUTTSCHRUTTER, H; SNIJDER, JAM

    1993-01-01

    Eight strains of Streptococcus pneumoniae were tested in vitro for their ability to produce capsular antigen in the presence of penicillin. It was found that, provided 10(6) to 10(7) pneumococci/ml were present, capsular antigen could be detected during the 72 h in which the experiment was

  18. Coombs Antiglobulin Test Using Brucella abortus 99 as Antigen To Detect Incomplete Antibodies Induced by B. abortus RB51 Vaccine in Cattle

    OpenAIRE

    Ciuchini, Franco; Adone, Rosanna; Pasquali, Paolo

    2002-01-01

    This study showed that vaccination of cattle with Brucella abortus rough strain RB51 induces incomplete antibodies that can be detectable by a Coombs antiglobulin test using the B. abortus 99 smooth strain.

  19. DETECTION OF CANINE PARVOVIRUS ANTIGEN IN DOGS IN KUMASI, GHANA.

    Science.gov (United States)

    Folitse, R D; Kodie, D O; Amemor, E; Dei, D; Tasiame, W; Burimuah, V; Emikpe, B O

    2018-01-01

    Canine Parvovirus (CPV) in dogs has been documented in many countries. However, evidence of the infection is scanty in Ghana. This study was conducted to detect canine parvovirus antigen in dogs presented with diarrhoea to the Government Veterinary Clinic in Kumasi, Ghana. Faecal samples from 72 dogs presented with diarrhoea were tested for the presence of canine parvovirus antigen using commercially available rapid test kit (BIT ® Rapid Colour Canine Parvovirus Ag Test Kit, BIOINDIST Co. Ltd, Korea) based on the principle of immunochromatography. Influence of breed, sex, age, vaccination history and the nature of diarrhoea were assessed. Data obtained was analysed with SPSS and subjected to the chi-square test. Significance was at α 0.05 . We found 61.11% tested positive (44/72) for CPV. Based on sex, 61.54% of males (20/33) and 60.61% of females tested positive (24/39). A total of 65.67% of samples from puppies below 6 months were positive. 56.25% of CPV vaccinated dogs and 70.83% of unvaccinated dogs were positive respectively. 69.05% of samples from haemorrhagic diarrhoeic dogs and 50.00% from non-haemorrhagic diarrhoeic dogs were positive of CPV. The study is the first documented evidence of the existence of CPV in Ghana. It also revealed that absence of bloody diarrhoea does not necessarily rule out CPV infection.

  20. DETECTION OF CANINE PARVOVIRUS ANTIGEN IN DOGS IN KUMASI, GHANA

    Science.gov (United States)

    Folitse, R. D; Kodie, D.O; Amemor, E.; Dei, D.; Tasiame, W.; Burimuah, V.; Emikpe, B.O

    2018-01-01

    Background: Canine Parvovirus (CPV) in dogs has been documented in many countries. However, evidence of the infection is scanty in Ghana. This study was conducted to detect canine parvovirus antigen in dogs presented with diarrhoea to the Government Veterinary Clinic in Kumasi, Ghana. Materials and Methods: Faecal samples from 72 dogs presented with diarrhoea were tested for the presence of canine parvovirus antigen using commercially available rapid test kit (BIT® Rapid Colour Canine Parvovirus Ag Test Kit, BIOINDIST Co. Ltd, Korea) based on the principle of immunochromatography. Influence of breed, sex, age, vaccination history and the nature of diarrhoea were assessed. Data obtained was analysed with SPSS and subjected to the chi-square test. Significance was at α0.05 Results: We found 61.11% tested positive (44/72) for CPV. Based on sex, 61.54% of males (20/33) and 60.61% of females tested positive (24/39). A total of 65.67% of samples from puppies below 6 months were positive. 56.25% of CPV vaccinated dogs and 70.83% of unvaccinated dogs were positive respectively. 69.05% of samples from haemorrhagic diarrhoeic dogs and 50.00% from non-haemorrhagic diarrhoeic dogs were positive of CPV. Conclusion: The study is the first documented evidence of the existence of CPV in Ghana. It also revealed that absence of bloody diarrhoea does not necessarily rule out CPV infection. PMID:29302647

  1. Detection of Rabies antigen in brains of suspected Rabid dogs ...

    African Journals Online (AJOL)

    Objective: To detect the presence of rabies antigen in brains of suspected rabid dogs. Materials and Methods: Ninety six (96) brain specimens from suspected rabid dogs were examined for the presence of rabies antigen using Seller's staining technique and enzyme immunoassay. Results: The two techniques were both ...

  2. Development of recombinant antigen array for simultaneous detection of viral antibodies.

    Directory of Open Access Journals (Sweden)

    Yi Liu

    Full Text Available Protein microarrays have been developed to study antibody reactivity against a large number of antigens, demonstrating extensive perspective for clinical application. We developed a viral antigen array by spotting four recombinant antigens and synthetic peptide, including glycoprotein G of herpes simplex virus (HSV type 1 and 2, phosphoprotein 150 of cytomegalovirus (CMV, Rubella virus (RV core plus glycoprotein E1 and E2 as well as a E1 peptide with the optimal concentrations on activated glass slides to simultaneously detect IgG and IgM against HSV1, HSV2, CMV and RV in clinical specimens of sera and cerebrospinal fluids (CSFs. The positive reference sera were initially used to measure the sensitivity and specificity of the array with the optimal conditions. Then clinical specimens of 144 sera and 93 CSFs were tested for IgG and IgM antibodies directed against HSV1, HSV2, CMV and RV by the antigen array. Specificity of the antigen array for viral antibodies detection was satisfying compared to commercial ELISA kits but sensitivity of the array varied relying on quality and antigenic epitopes of the spotting antigens. In short, the recombinant antigen array has potential to simultaneous detect multiple viral antibodies using minute amount (3 µl of samples, which holds the particularly advantage to detect viral antibodies in clinical CSFs being suspicious of neonatal meningitis and encephalitis.

  3. Using the AD12-ICT rapid-format test to detect Wuchereria bancrofti circulating antigens in comparison to Og4C3-ELISA and nucleopore membrane filtration and microscopy techniques.

    Science.gov (United States)

    El-Moamly, Amal Abdul-Rasheed; El-Sweify, Mohamed Aly; Hafez, Mohamad Abdul

    2012-09-01

    Lymphatic filariasis (LF) continues to be a major source of permanent disability and an impediment to socio-economic development in 73 countries where more than 1 billion people are at risk and over 120 millions are infected. The global drive to eliminate LF necessitates an increasing demand for valid, reliable and rapid diagnostic tests. This study aimed to assess the performance of the AD12 rapid format immunochromatographic test (ICT) to detect Wuchereria bancrofti circulating antigens, against the combined gold standard: TropBio Og4C3-ELISA (enzyme-linked immunosorbent assay) which detects circulating filarial antigen (CFA) and the nucleopore membrane filtration and microscopic examination. This prospective case-control study involved 647 asymptomatic migrant workers from filariasis-endemic countries. Of these specimens, 32 were positive for microfilaremia using the membrane filtration and microscopy, 142 positive by ELISA (of which 32 had microfilaremia), and 128 positive by the ICT (of which 31 had microfilaremia). The performance of the ICT was calculated against 32 true-positive and 90 true-negative cases. For the detection of CFA, the ICT had a sensitivity of 97% (95% confidence interval [CI] 91-103), specificity 100% (95% CI 100-100), Positive Predictive Value (PPV) 100% (95% CI 100-100), Negative Predictive Value (NPV) 99% (95% CI 97-101); and the total accuracy of the test was 99% (95% CI 98-101). The agreement between ICT and ELISA in detecting W. bancrofti antigens was excellent (kappa = 0.934; p = 0.000). In conclusion, the AD12-ICT test for the detection of W. bancrofti-CFA was sensitive and specific and comparable to the performance of ELISA. The ICT would be a useful additional test to facilitate the proposed strategies for control and elimination of LF. Because it is rapid, simple to perform, and does not require the use of special equipment, the ICT may be most appropriate in screening programs and in monitoring the possible risk of introducing

  4. Anti-hepatitis B core antigen testing with detection and characterization of occult hepatitis B virus by an in-house nucleic acid testing among blood donors in Behrampur, Ganjam, Orissa in southeastern India: implications for transfusion

    Directory of Open Access Journals (Sweden)

    Panigrahi Rajesh

    2010-08-01

    Full Text Available Abstract Background Occult hepatitis B virus (HBV infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. Methods A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT for detection of occult HBV infection and surface gene was analyzed after direct sequencing. Results A total of 220 (30.1% HBsAg negative donors were antiHBc positive, of them 66 (30% were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3% was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Conclusion Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India.

  5. Anti-hepatitis B core antigen testing with detection and characterization of occult hepatitis B virus by an in-house nucleic acid testing among blood donors in Behrampur, Ganjam, Orissa in southeastern India: implications for transfusion.

    Science.gov (United States)

    Panigrahi, Rajesh; Biswas, Avik; Datta, Sibnarayan; Banerjee, Arup; Chandra, Partha K; Mahapatra, Pradip K; Patnaik, Bharat; Chakrabarti, Sekhar; Chakravarty, Runu

    2010-08-27

    Occult hepatitis B virus (HBV) infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg) testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT) for detection of occult HBV infection and surface gene was analyzed after direct sequencing. A total of 220 (30.1%) HBsAg negative donors were antiHBc positive, of them 66 (30%) were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3%) was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India.

  6. Accuracy of PfHRP2 versus Pf-pLDH antigen detection by malaria rapid diagnostic tests in hospitalized children in a seasonal hyperendemic malaria transmission area in Burkina Faso.

    Science.gov (United States)

    Maltha, Jessica; Guiraud, Issa; Lompo, Palpouguini; Kaboré, Bérenger; Gillet, Philippe; Van Geet, Chris; Tinto, Halidou; Jacobs, Jan

    2014-01-13

    In most sub-Saharan African countries malaria rapid diagnostic tests (RDTs) are now used for the diagnosis of malaria. Most RDTs used detect Plasmodium falciparum histidine-rich protein-2 (PfHRP2), though P. falciparum-specific parasite lactate dehydrogenase (Pf-pLDH)-detecting RDTs may have advantages over PfHRP2-detecting RDTs. Only few data are available on the use of RDTs in severe illness and the present study compared Pf-pLDH to PfHRP2-detection. Hospitalized children aged one month to 14 years presenting with fever or severe illness were included over one year. Venous blood samples were drawn for malaria diagnosis (microscopy and RDT), culture and complete blood count. Leftovers were stored at -80 °C and used for additional RDT analysis and PCR. An RDT targeting both PfHRP2 and Pf-pLDH was performed on all samples for direct comparison of diagnostic accuracy with microscopy as reference method. PCR was performed to explore false-positive RDT results. In 376 of 694 (54.2%) included children, malaria was microscopically confirmed. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value were 100.0, 70.9, 69.4 and 100.0%, respectively for PfHRP2-detection and 98.7, 94.0, 91.6 and 99.1%, respectively for Pf-pLDH-detection. Specificity and PPV were significantly lower for PfHRP2-detection (p <0.001). For both detection antigens, specificity was lowest for children one to five years and in the rainy season. PPV for both antigens was highest in the rainy season, because of higher malaria prevalence. False positive PfHRP2 results were associated with prior anti-malarial treatment and positive PCR results (98/114 (86.0%) samples tested). Among children presenting with severe febrile illness in a seasonal hyperendemic malaria transmission area, the present study observed similar sensitivity but lower specificity and PPV of PfHRP2 compared to Pf-pLDH-detection. Further studies should assess the diagnostic accuracy and safety of an

  7. A protein-conjugate approach to develop a monoclonal antibody-based antigen detection test for the diagnosis of human brucellosis

    NARCIS (Netherlands)

    Patra, Kailash P.; Saito, Mayuko; Atluri, Vidya L.; Rolán, Hortensia G.; Young, Briana; Kerrinnes, Tobias; Smits, Henk; Ricaldi, Jessica N.; Gotuzzo, Eduardo; Gilman, Robert H.; Tsolis, Renee M.; Vinetz, Joseph M.

    2014-01-01

    Human brucellosis is most commonly diagnosed by serology based on agglutination of fixed Brucella abortus as antigen. Nucleic acid amplification techniques have not proven capable of reproducibly and sensitively demonstrating the presence of Brucella DNA in clinical specimens. We sought to optimize

  8. Rapid solid-phase radioimmunoassay for detection of equine infectious anemia viral antigen and antibodies: parameters involved in standardization

    International Nuclear Information System (INIS)

    Horenstein, A.L.; Feinstein, R.E.

    1985-01-01

    Solid-phase radioimmunoassays (SPRIA) are described for the detection of equine infectious anemia (EIA) viral antigen and antibodies. Protein-antigen P29 currently used in the agar-gel immunodiffusion (AGID) test was used as antigen in the SPRIA. The specificity of the reaction was assessed by inhibition with the antigen. The reaction of immune serum against EIA-virus antigen adsorbed to the wells, was completely inhibited by the antigen in solution. This property was applied in an indirect competitive SPRIA for the detection of viral protein P29. The detection threshold of the SPRIA for EIA virus protein was about 5 ng and about 1 ng of antibody can be detected. The assay is rapid, specific and sensitive and allows the testing of multiple serum samples with the advantage of employing a single secondary labelled antibody. (orig.)

  9. Detection of HBs antigens and antibodies by immunoenzymology and radioimmunology. Comparison of the results

    International Nuclear Information System (INIS)

    Fauchet, R.; Genetet, B.; Phengsavath

    1981-01-01

    The respective sensitivity threshold of immunoenzymology and radioimmunology in HBs antigen and antibody detection were compared and the optical density (o.d.) and counts per minute (cpm) values were correlated with the concentration in ng/ml of a given sample. The sensitivity comparison between RIA and EIA appears in favour of the former technique for both HBs antigen and HBs antibody detection. However the procedure tried here to detect HBs antibodies by immunoenzymology is simple, requires only the choice of neutralising antigenic pool and sensitivity threshold and could usefully be generalized for teams not authorized to handle radioelements. Quantification of the HBs antigen content in ng/ml is a difficult operation, needing great care in the dilution of the sera tested. The reproducibility is not perfect. The semi-quantitative RIA determination expressed in R.U. (radioimmunological units) seems adequate as a mean to follow the progress of an HBs antibody in both liver disease and vaccination [fr

  10. Real-time prostate-specific antigen detection with prostate-specific antigen imprinted capacitive biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Ertürk, Gizem [Department of Biotechnology, Lund University, Lund (Sweden); Department of Biology, Hacettepe University, Ankara (Turkey); Hedström, Martin [Department of Biotechnology, Lund University, Lund (Sweden); CapSenze HB, Medicon Village, SE-223 63 Lund (Sweden); Tümer, M. Aşkın [Department of Biology, Hacettepe University, Ankara (Turkey); Denizli, Adil [Department of Chemistry, Hacettepe University, Ankara (Turkey); Mattiasson, Bo, E-mail: Bo.Mattiasson@biotek.lu.se [Department of Biotechnology, Lund University, Lund (Sweden); CapSenze HB, Medicon Village, SE-223 63 Lund (Sweden)

    2015-09-03

    Prostate specific antigen (PSA) is a valuable biomarker for early detection of prostate cancer, the third most common cancer in men. Ultrasensitive detection of PSA is crucial to screen the prostate cancer in an early stage and to detect the recurrence of the disease after treatment. In this report, microcontact-PSA imprinted (PSA-MIP) capacitive biosensor chip was developed for real-time, highly sensitive and selective detection of PSA. PSA-MIP electrodes were prepared in the presence of methacrylic acid (MAA) as the functional monomer and ethylene glycol dimethacrylate (EGDMA) as the cross-linker via UV polymerization. Immobilized Anti-PSA antibodies on electrodes (Anti-PSA) for capacitance measurements were also prepared to compare the detection performances of both methods. The electrodes were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and cyclic voltammetry (CV) and real-time PSA detection was performed with standard PSA solutions in the concentration range of 10 fg mL{sup −1}–100 ng mL{sup −1}. The detection limits were found as 8.0 × 10{sup −5} ng mL{sup −1} (16 × 10{sup −17} M) and 6.0 × 10{sup −4} ng mL{sup −1} (12 × 10{sup −16} M) for PSA-MIP and Anti-PSA electrodes, respectively. Selectivity studies were performed against HSA and IgG and selectivity coefficients were calculated. PSA detection was also carried out from diluted human serum samples and finally, reproducibility of the electrodes was tested. The results are promising and show that when the sensitivity of the capacitive system is combined with the selectivity and reproducibility of the microcontact-imprinting procedure, the resulting system might be used successfully for real-time detection of various analytes even in very low concentrations. - Highlights: • Microcontact imprinting method was used for preparing the sensor chip for capacitive biosensing. • High sensitivity was obtained. • Good selectivity was

  11. Real-time prostate-specific antigen detection with prostate-specific antigen imprinted capacitive biosensors

    International Nuclear Information System (INIS)

    Ertürk, Gizem; Hedström, Martin; Tümer, M. Aşkın; Denizli, Adil; Mattiasson, Bo

    2015-01-01

    Prostate specific antigen (PSA) is a valuable biomarker for early detection of prostate cancer, the third most common cancer in men. Ultrasensitive detection of PSA is crucial to screen the prostate cancer in an early stage and to detect the recurrence of the disease after treatment. In this report, microcontact-PSA imprinted (PSA-MIP) capacitive biosensor chip was developed for real-time, highly sensitive and selective detection of PSA. PSA-MIP electrodes were prepared in the presence of methacrylic acid (MAA) as the functional monomer and ethylene glycol dimethacrylate (EGDMA) as the cross-linker via UV polymerization. Immobilized Anti-PSA antibodies on electrodes (Anti-PSA) for capacitance measurements were also prepared to compare the detection performances of both methods. The electrodes were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and cyclic voltammetry (CV) and real-time PSA detection was performed with standard PSA solutions in the concentration range of 10 fg mL"−"1–100 ng mL"−"1. The detection limits were found as 8.0 × 10"−"5 ng mL"−"1 (16 × 10"−"1"7 M) and 6.0 × 10"−"4 ng mL"−"1 (12 × 10"−"1"6 M) for PSA-MIP and Anti-PSA electrodes, respectively. Selectivity studies were performed against HSA and IgG and selectivity coefficients were calculated. PSA detection was also carried out from diluted human serum samples and finally, reproducibility of the electrodes was tested. The results are promising and show that when the sensitivity of the capacitive system is combined with the selectivity and reproducibility of the microcontact-imprinting procedure, the resulting system might be used successfully for real-time detection of various analytes even in very low concentrations. - Highlights: • Microcontact imprinting method was used for preparing the sensor chip for capacitive biosensing. • High sensitivity was obtained. • Good selectivity was demonstrated. • Stability of

  12. Effect of vaccination on parvovirus antigen testing in kittens.

    Science.gov (United States)

    Patterson, Erin V; Reese, Michael J; Tucker, Sylvia J; Dubovi, Edward J; Crawford, P Cynda; Levy, Julie K

    2007-02-01

    To determine the frequency and duration of feline panleukopenia virus (FPV) vaccine-induced interference with fecal parvovirus diagnostic testing in cats. Prospective controlled study. Sixty-four 8- to 10-week-old specific-pathogen-free kittens. Kittens were inoculated once with 1 of 8 commercial multivalent vaccines containing modified-live virus (MLV) or inactivated FPV by the SC or intranasal routes. Feces were tested for parvovirus antigen immediately prior to vaccination, then daily for 14 days with 3 tests designed for detection of canine parvovirus. Serum anti-FPV antibody titers were determined by use of hemagglutination inhibition prior to vaccination and 14 days later. All fecal parvovirus test results were negative prior to vaccination. After vaccination, 1 kitten had positive test results with test 1, 4 kittens had positive results with test 2, and 13 kittens had positive results with test 3. Only 1 kitten had positive results with all 3 tests, and only 2 of those tests were subjectively considered to have strongly positive results. At 14 days after vaccination, 31% of kittens receiving inactivated vaccines had protective FPV titers, whereas 85% of kittens receiving MLV vaccines had protective titers. Animal shelter veterinarians should select fecal tests for parvovirus detection that have high sensitivity for FPV and low frequency of vaccine-related test interference. Positive parvovirus test results should be interpreted in light of clinical signs, vaccination history, and results of confirmatory testing. Despite the possibility of test interference, the benefit provided by universal MLV FPV vaccination of cats in high-risk environments such as shelters outweighs the impact on diagnostic test accuracy.

  13. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  14. Prostate-specific antigen testing accuracy in community practice

    Directory of Open Access Journals (Sweden)

    Adams-Cameron Meg

    2002-10-01

    Full Text Available Abstract Background Most data on prostate-specific antigen (PSA testing come from urologic cohorts comprised of volunteers for screening programs. We evaluated the diagnostic accuracy of PSA testing for detecting prostate cancer in community practice. Methods PSA testing results were compared with a reference standard of prostate biopsy. Subjects were 2,620 men 40 years and older undergoing (PSA testing and biopsy from 1/1/95 through 12/31/98 in the Albuquerque, New Mexico metropolitan area. Diagnostic measures included the area under the receiver-operating characteristic curve, sensitivity, specificity, and likelihood ratios. Results Cancer was detected in 930 subjects (35%. The area under the ROC curve was 0.67 and the PSA cutpoint of 4 ng/ml had a sensitivity of 86% and a specificity of 33%. The likelihood ratio for a positive test (LR+ was 1.28 and 0.42 for a negative test (LR-. PSA testing was most sensitive (90% but least specific (27% in older men. Age-specific reference ranges improved specificity in older men (49% but decreased sensitivity (70%, with an LR+ of 1.38. Lowering the PSA cutpoint to 2 ng/ml resulted in a sensitivity of 95%, a specificity of 20%, and an LR+ of 1.19. Conclusions PSA testing had fair discriminating power for detecting prostate cancer in community practice. The PSA cutpoint of 4 ng/ml was sensitive but relatively non-specific and associated likelihood ratios only moderately revised probabilities for cancer. Using age-specific reference ranges and a PSA cutpoint below 4 ng/ml improved test specificity and sensitivity, respectively, but did not improve the overall accuracy of PSA testing.

  15. [The clinical value of urinary antigen detection of Legionella pneumonia].

    Science.gov (United States)

    Jiang, Luxi; Chen, Yu; Xia, Shuyue; Ma, Jiangwei; Zhao, Hongwen; Lu, Ye; Tao, Sixu; Zhao, Li

    2015-01-01

    To investigate the clinical value of urinary antigen detection of Legionella, and to describe the clinical characteristics of Legionella pneumonia. Patients with suspected Legionella pneumonia were enrolled from the Respiratory departments of 3 tertiary hospitals in Shenyang during May 2011 to November 2013. Urinary Legionella antigen was detected for all the enrolled patients. Bacterial culture, polymerase chain reaction (PCR) for Legionella, and double Legionella antibody detection in sera were performed for each patient whose urinary antigen was positive. Patients confirmed to have Legionella pneumonia were pooled and analyzed. Totally 13 cases presenting with pneumonia were positive for Legionella by the urinary antigen method, and in one of them Legionella strain was isolated from the secretion of lower respiratory tract. PCR detection was performed in 8 patients, and 4 of them were positive. Legionella antibody detection was performed in 12 patients, and 7 of them were positive. Nine patients had a history of exposure to Legionella high-risk environments. The characteristics of the cases with Legionella pneumonia were as follows: characteristic orange sputum in 4 patients, digestive symptoms in 6, neurologic disorders in 8, hyponatremia in 10, hypoxia with oxygenation index 130) in 8 patients . Chest CT scan showed bilateral involvement in 6, ground-glass opacity combined with consolidation in 11, and moderate pleural effusion in 11 patients. Cavity and reversed halo sign were found in one case, respectively. All of the patients received fluoroquinolone treatment, and 11 patients recovered completely while 2 died of multiple organ dysfunction syndrome, one of them was complicated with secondary infection. Detection of urinary antigen of Legionella is very useful in the diagnosis of Legionella pneumonia. Attention should be paid to exposure history to the high-risk environments and multiple organ impairment when Legionella infection is suspected. Orange sputum

  16. Detection of Rabies Antigen in the Brain Tissues of Apparetly ...

    African Journals Online (AJOL)

    Rabies is a serious public health hazard and recently outbreaks of the disease have been reported in three local government areas in Cross River State. Detection of rabies antigen in the brain tissues of apparently healthy dogs indicates the presence of rabies virus and this is a significant factor in the transmission and ...

  17. Detection and quantification of Duffy antigen on bovine red blood cell membranes using a polyclonal antibody

    Directory of Open Access Journals (Sweden)

    Ana Teresa B.F. Antonangelo

    2012-09-01

    Full Text Available Babesiosis is one of the most important diseases affecting livestock agriculture worldwide. Animals from the subspecies Bos taurus indicus are more resistant to babesiosis than those from Bos taurus taurus. The genera Babesia and Plasmodium are Apicomplexa hemoparasites and share features such as invasion of red blood cells (RBC. The glycoprotein Duffy is the only human erythrocyte receptor for Pasmodium vivax and a mutation which abolishes expression of this glycoprotein on erythrocyte surfaces is responsible for making the majority of people originating from the indigenous populations of West Africa resistant to P. vivax. The current work detected and quantified the Duffy antigen on Bos taurus indicus and Bos taurus taurus erythrocyte surfaces using a polyclonal antibody in order to investigate if differences in susceptibility to Babesia are due to different levels of Duffy antigen expression on the RBCs of these animals, as is known to be the case in human beings for interactions of Plasmodium vivax-Duffy antigen. ELISA tests showed that the antibody that was raised against Duffy antigens detected the presence of Duffy antigen in both subspecies and that the amount of this antigen on those erythrocyte membranes was similar. These results indicate that the greater resistance of B. taurus indicus to babesiosis cannot be explained by the absence or lower expression of Duffy antigen on RBC surfaces.

  18. Detection of HCV core antigen and its diagnostic significance

    Directory of Open Access Journals (Sweden)

    YANG Jie

    2013-02-01

    Full Text Available ObjectiveTo compare the abilities of the hepatitis C virus (HCV core antigen (cAg test and the HCV RNA assay for confirming anti-HCV presence in order to determine the clinical utility of the HCV-cAg as an alternative or confirmatory diagnostic tool. MethodsSerum samples collected from 158 patients diagnosed with HCV infection were subjected to the enzyme-linked immunosorbent assay-based HCV-cAg test. The optical density (OD measured values were used to calculate the ratio of specimen absorbance to the cutoff value (S/CO. Simultaneously, the serum samples were subjected to PCR-based nucleic acid amplification quantitative fluorescence detection of HCV RNA. ResultsNone of the serum samples had a S/CO value <1 for the HCV-cAg test (100% negative, but all of the samples had a S/CO value >5 (100% positive. The HCV-cAg test sensitivity was 87.05%, specificity was 76.67%, positive predictive value was 9653%, and negative predictive value was 44.23%. As the S/CO value gradually increased, the significantly higher positive coincident rate of the HCV RNA test decreased. The HCV RNA negative coincident rate was significantly higher than that of the HCV-cAg test. HCV-cAg S/CO values between 1 and 2 corresponded to an HCV RNA values between 1.0×103 copies/ml and 1.0×104 copies/ml. The highest S/CO value obtained was 1.992. ConclusionThe HCV-cAg test is comparable to the HCV RNA assay for diagnosing HCV infection.

  19. Potential radioimmunoassay system for detection of Hanganutziu-Deicher type heterophile antigen(s) and antibodies in tissues and fluids

    Energy Technology Data Exchange (ETDEWEB)

    Mukuria, J C; Naiki, Masaharu; Hashimoto, Masato; Nishiura, Katsumi; Okabe, Masahiro; Kato, Shiro

    1985-06-12

    A relatively simple, specific and sensitive radioimmunoassay system has been developed for the detection of heterophile Hanganutziu-Deicher (H-D) antigen(s) and antibodies. The SVI-labeled H-D antigen-active molecule used for the assay is a bovine erythrocyte major glycoprotein previously found to have a strong H-D antigen potency. Different H-D antigen-active molecules were compared for heterophile H-D antigen potency. Eight different lung cancer tissues were assayed for H-D antigen. The sera from the 8 lung cancer patients were also screened by ELISA and RIA in an attmept to correlate expression of H-D antigen on tissues with elevation of H-D antibodies.

  20. Pelacakan Secara Imunohistokimiawi Antigen Virus pada Ayam yang Diinfeksi dengan Virus Penyakit Tetelo (IMMUNOHISTOCHEMICAL DETECTION OF VIRAL ANTIGEN IN TISSUE OF CHICKENS EXPERIMENTALLY INFECTED WITH NEWCASTLE DISEASE VIRUS

    Directory of Open Access Journals (Sweden)

    Anak Agung Ayu Mirah Adi

    2013-07-01

    Full Text Available In order to study the distribution of Newcastle disease virus (NDV following infection, chickenswere experimentally infected with visceretropic velogenic NDV isolate. Monoclonal antibodies (mAbsagainst the NDV LaSota vaccine strain were then produced to detect viral antigen in the infectedorgans. The mAbs were firstly tested for their specificity by enzyme linked immunosorbent assay(ELISA using NDV and normal allantoic fluids as antigens. Eight mAbs specific against NDVwere isolated and two mAbs were used for immunodetection of NDV antigen in chicken’s tissues.By immunohistochemistry labeled streptavidin-biotin (LSAB staining NDV–antigen was detectedin paraffin embedded tissues of NDV-infected chickens. NDV antigen was not detected in noninfected chickens. In the infected chickens, high intensity of NDV antigen was detected in thelymphoid tissues, lung and intestine. The NDV antigen with a lesser intensity was detected in thebrain, trachea, liver and myocardium. This study shows that although viscerotropic velogenicNDV isolate can infect almost all organs, the main target of infection are lung, intestine andlymphoids tissues

  1. Dengue NS1 Antigen - for Early Detection of Dengue Virus Infection

    Directory of Open Access Journals (Sweden)

    Amol Hartalkar

    2015-08-01

    Full Text Available Objectives: To evaluate the efficacy of NS1 antigen assay for early diagnosis of dengue virus infection in a tertiary care hospital. Methods: This cross sectional study was carried out in department of Medicine from August to December 2013. Total 100 patients with dengue fever were included. Complete blood count, alanine aminotransferase (ALT, aspartate aminotransferase (AST, Dengue NS1 antigen and IgM and IgG antibodies of dengue virus were done in all cases. Results: Of the 100 sera tested, 75% were positive for dengue virus infection based on dengue NS1 antigen, IgM antibody and IgG antibody. Dengue NS1 antigen and IgM, IgG antibody were able to detect dengue virus infection between day 1 to day 8 in 92% of samples, 86.7% of samples and 82.6% of samples respectively. Sixty nine percent (69% were found positive for dengue NS1 antigen, 65% were IgM positive and 62% were IgG positive. Based on the dengue NS1 antigen and IgM antibody combination, 74% were positive for dengue virus infections. Sensitivity of Dengue NS1 antigen was 92.3% and specificity of 74.28% in comparison to IgM antibody. Detection rate increased to 75%, based on the antigen and IgG antibody combination. Sensitivity of dengue NS1 antigen was 90.3% and specificity of 65.8% in comparison to IgG antibody. Conclusion: Dengue NS1 antigen is a useful, sensitive and specific test for early diagnosis of dengue virus infection and it improves diagnostic efficiency in combination with antibody test. Key words: Dengue fever, NS1 antigen. Introduction: Dengue fever (DF is the most common arboviral illness in humans. Each year, an estimated 50-100 million cases of dengue fever and 500,000 cases of dengue hemorrhagic fever occur worldwide, with 30000 deaths (mainly in children. Globally 2.5-3 billion people in approximately 112 tropical and subtropical countries are at risk of dengue.of samples respectively. Sixty nine percent (69% were found positive for dengue NS1 antigen, 65% were Ig

  2. Synthetic oligonucleotide antigens modified with locked nucleic acids detect disease specific antibodies

    DEFF Research Database (Denmark)

    Samuelsen, Simone V; Solov'yov, Ilia A.; Balboni, Imelda M.

    2016-01-01

    New techniques to detect and quantify antibodies to nucleic acids would provide a significant advance over current methods, which often lack specificity. We investigate the potential of novel antigens containing locked nucleic acids (LNAs) as targets for antibodies. Particularly, employing...... molecular dynamics we predict optimal nucleotide composition for targeting DNA-binding antibodies. As a proof of concept, we address a problem of detecting anti-DNA antibodies that are characteristic of systemic lupus erythematosus, a chronic autoimmune disease with multiple manifestations. We test the best...... that the novel method is a promising tool to create antigens for research and point-of-care monitoring of anti-DNA antibodies....

  3. [Contribution of urinary pneumococcal antigen detection combined with the research of legionella antigen for diagnosis of pneumonia in hospitalized patients].

    Science.gov (United States)

    Honoré, S; Trillard, M; Ould-Hocine, Z; Lesprit, P; Deforges, L; Legrand, P

    2004-10-01

    Bacteriological confirmation of pneumonia (PNM) in hospitalized patients is often erratic or belated. Because of importance of prognosis, early adaptation of treatment requires an empirical antimicrobial therapy (generally aminopenicillin and macrolide combination). The starting therapeutic strategy should profit by a fast and reliable test asserting a pneumococcal etiology. The Binax Now S. pneumoniae (BNP) test allows an urinary pneumococcal antigen (UPA) detection using an immunochromatographic membrane assay within 15 minutes. We first evaluated the BNP test for 28 patients with pneumococcal PNM proved by culture, and 118 negative control patients without PNM. The BNP test was then evaluated by testing urine from 158 hospitalized patients with a clinical picture of PNM (community-acquired: 90, nosocomial: 68) for whom a research of urinary Legionella antigen (Binax Now) was prescribed and was positive for only two cases. 57 patients (36.1%) were hospitalized in ICU. The sensitivity was 71.4% (85.7% for the 21 bacteriemic PNM), and the specificity was 98.3%; that is consistent with previous published data. Among the 158 patients with PNM, UPA was detected in 17 cases (10.8%): 15 within the community-acquired PNM (16.7%) and 2 (2.9%) within the nosocomial cases. The pneumococcal etiology was confirmed by bacteriological samples in 7/17 patients (6 by blood cultures). The 10 others showed clinical and radiological features in agreement with a pneumococcal PNM. Among the 141 patients with negative AUP, S. pneumoniae was isolated from 6 of them (2 in blood cultures). The Binax Now S. pneumoniae test allowed a fast and reliable etiological diagnosis in 10.8% of hospitalized PNM (16.7% of the community-acquired cases) having a research of urinary Legionella antigen (conceiving with severity factors). So it could conduce to an improved adjustment of the starting antimicrobial therapy of hospitalized adult patients with PNM.

  4. Detecting West Nile virus in owls and raptors by an antigen-capture assay.

    Science.gov (United States)

    Gancz, Ady Y; Campbell, Douglas G; Barker, Ian K; Lindsay, Robbin; Hunter, Bruce

    2004-12-01

    We evaluated a rapid antigen-capture assay (VecTest) for detection of West Nile virus in oropharyngeal and cloacal swabs, collected at necropsy from owls (N = 93) and raptors (N = 27). Sensitivity was 93.5%-95.2% for northern owl species but raptors.

  5. Detecting West Nile Virus in Owls and Raptors by an Antigen-capture Assay

    OpenAIRE

    Gancz, Ady Y.; Campbell, Douglas G.; Barker, Ian K.; Lindsay, Robbin; Hunter, Bruce

    2004-01-01

    We evaluated a rapid antigen-capture assay (VecTest) for detection of West Nile virus in oropharyngeal and cloacal swabs, collected at necropsy from owls (N = 93) and raptors (N = 27). Sensitivity was 93.5%–95.2% for northern owl species but

  6. Detection of Helicobacter pylori urease antigen in saliva in patients with different gastric H. pylori status.

    Science.gov (United States)

    El Khadir, Mounia; Alaoui Boukhris, Samia; Benajah, Dafr-Allah; El Rhazi, Karima; Ibrahimi, Sidi Adil; El Abkari, Mohamed; Harmouch, Taoufiq; Nejjari, Chakib; Mahmoud, Mustapha; Benlemlih, Mohamed; Bennani, Bahia

    2016-07-01

    Finding a simple, accurate, and noninvasive diagnosis method is a substantial challenge for the detection of Helicobacter pylori. The aim of the present study was to compare the presence of H. pylori urease antigen in saliva with the presence of this bacterium in gastric mucosa. Saliva samples and gastric biopsies were taken from 153 consenting Moroccan patients. Saliva samples were analyzed using an immunochromatographic test for urease antigen H. pylori detection. Thereafter, the gastric biopsies were analyzed by histology and polymerase chain reaction (PCR) to detect this bacterium. From a total of 153 recruited Moroccan patients, H. pylori was detected in 28 (18.30%), 87 (57.24%), and 69 (45.10%) cases by saliva test, histology, and PCR, respectively. A significant association was observed between the presence of H. pylori antigen in saliva and age. However, no association was found with sex, H. pylori virulence factors, gastric disease outcome, and density of the bacterium on the gastric mucosa. Considering that only 90 patients presented concordant results on H. pylori diagnosis (positive or negative) by both histology and PCR, the immunochromatographic test showed very low sensitivity (29.79%) and high specificity (90.70%). Of these two tests, the positive and negative predictive values were 77.78% and 54.17%, respectively. The accuracy of the test for salivary detection of urease antigen H. pylori was 58.89%. This study demonstrated a low detection rate of H. pylori antigens in saliva compared with the presence of this bacterium in gastric mucosa, suggesting that saliva cannot be used as a suitable sample for the diagnosis of H. pylori in our study population. Copyright © 2016. Published by Elsevier Taiwan LLC.

  7. [The efficiency of the enzyme immunoassay test system opisthorchiasis-CIC-EIA-best to detect circulating immune complexes containing opisthorchis antigens in the serum of patients with opisthorchiasis].

    Science.gov (United States)

    Starkova, T V; Poletaeva, O G; Kovrova, E A; Krasovskaia, N N; Tkachenko, T N; Masiago, A V; Ofitserov, V I; Tereshchenko, A Iu

    2011-01-01

    The efficacy of a kit of Opisthorchiasis-CIC-EIA-Best reagents was evaluated using 270 sera from patients in the study and control groups. The kit showed a sufficient sensitivity (not less than 87.2%) and a high specificity (not less than 97.9%). The use of the above kit of the reagents for enzyme immunoassay in practical healthcare enables one to increase detection rates among the infested subjects on comprehensive examination of those with suspected opisthorchiasis.

  8. Performance Assessment of Four Chimeric Trypanosoma cruzi Antigens Based on Antigen-Antibody Detection for Diagnosis of Chronic Chagas Disease.

    Directory of Open Access Journals (Sweden)

    Fred Luciano Neves Santos

    Full Text Available The performance of serologic tests in chronic Chagas disease diagnosis largely depends on the type and quality of the antigen preparations that are used for detection of anti-Trypanosoma cruzi antibodies. Whole-cell T. cruzi extracts or recombinant proteins have shown variation in the performance and cross-reactivity. Synthetic chimeric proteins comprising fragments of repetitive amino acids of several different proteins have been shown to improve assay performances to detect Chagasic infections. Here, we describe the production of four chimeric T. cruzi proteins and the assessment of their performance for diagnostic purposes. Circular Dichroism spectra indicated the absence of well-defined secondary structures, while polydispersity evaluated by Dynamic Light Scattering revealed only minor aggregates in 50 mM carbonate-bicarbonate (pH 9.6, demonstrating that it is an appropriate buffering system for sensitizing microplates. Serum samples from T. cruzi-infected and non-infected individuals were used to assess the performance of these antigens for detecting antibodies against T. cruzi, using both enzyme-linked immunosorbent assay and a liquid bead array platform. Performance parameters (AUC, sensitivity, specificity, accuracy and J index showed high diagnostic accuracy for all chimeric proteins for detection of specific anti-T. cruzi antibodies and differentiated seropositive individuals from those who were seronegative. Our data suggest that these four chimeric proteins are eligible for phase II studies.

  9. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  10. [The lysate and recombinant antigens in ELISA-test-systems for diagnostic of herpes simplex].

    Science.gov (United States)

    Ganova, L A; Kovtoniuk, G V; Korshun, L N; Kiseleva, E K; Tereshchenko, M I; Vudmaska, M I; Moĭsa, L N; Shevchuk, V A; Spivak, N Ia

    2014-08-01

    The lysate and recombinant antigens of various production included informula of ELISA-test-systems were analyzed. The ELISA-test-systems are used for detection of IgG to Herpes simplex virus type I and II. For testing the panel of serums PTH 201 (BBI Inc.) were used. The samples of this panel contain antibodies to Herpes simplex virus type I and II in mixed titers. The 69 serums of donors were used too (17 samples had IgG to Herpes simplex virus type I, 23 samples to Herpes simplex virus type II and 29 samples had no antibodies to Herpes simplex virus). The diagnostic capacity of mixture of recombinant antigens gG1 Herpes simplex virus type I and gG2 Herpes simplex virus type II (The research-and-production complex "DiaprofMed") was comparable with mixture of lysate antigen Herpes simplex virus type I and II (Membrane) EIE Antigen ("Virion Ltd."). In the test-systems for differentiation of IgG to Herpes simplex virus type I the recombinant antigen gG1 Herpes simplex virus type I proved to be comparable with commercial analogue Herpes simplex virus-1 gG1M ("Viral Therapeutics Inc."'). At the same time, capacity to detect IgG to Herpes simplex virus type II in recombinant protein gG2 Herpes simplex virus type II is significantly higher than in its analogue Herpes simplex virus-2 gG2c ("Viral Therapeutics Inc.").

  11. Detection of urinary excreted fungal galactomannan-like antigens for diagnosis of invasive aspergillosis.

    Directory of Open Access Journals (Sweden)

    Simon F Dufresne

    Full Text Available Mortality associated with invasive aspergillosis (IA remains high, partly because of delayed diagnosis. Detection of microbial exoantigens, released in serum and other body fluids during infection, may help timely diagnosis. In course of IA, Aspergillus galactomannan (GM, a well established polysaccharide biomarker, is released in body fluids including urine. Urine is an abundant, safely collected specimen, well-suited for point-of-care (POC testing, which could play an increasing role in screening for early disease. Our main objective was to demonstrate GM antigenuria as a clinically relevant biological phenomenon in IA and establish proof-of-concept that it could be translated to POC diagnosis. Utilizing a novel IgM monoclonal antibody (MAb476 that recognizes GM-like antigens from Aspergillus and other molds, we demonstrated antigenuria in an experimental animal IA model (guinea pig, as well as in human patients. In addition, we investigated the chemical nature of the urinary excreted antigen in human samples, characterized antigen detection in urine by immunoassays, described a putative assay inhibitor in urine, and indicated means of alleviation of the inhibition. We also designed and used a lateral flow immunochromatographic assay to detect urinary excreted antigen in a limited number of IA patient urine samples. In this study, we establish that POC diagnosis of IA based on urinary GM detection is feasible. Prospective studies will be necessary to establish the performance characteristics of an optimized device and define its optimal clinical use.

  12. Immunoliposome-PCR: a generic ultrasensitive quantitative antigen detection system

    Directory of Open Access Journals (Sweden)

    He Junkun

    2012-06-01

    Full Text Available Abstract Background The accurate quantification of antigens at low concentrations over a wide dynamic range is needed for identifying biomarkers associated with disease and detecting protein interactions in high-throughput microarrays used in proteomics. Here we report the development of an ultrasensitive quantitative assay format called immunoliposome polymerase chain reaction (ILPCR that fulfills these requirements. This method uses a liposome, with reporter DNA encapsulated inside and biotin-labeled polyethylene glycol (PEG phospholipid conjugates incorporated into the outer surface of the liposome, as a detection reagent. The antigenic target is immobilized in the well of a microplate by a capture antibody and the liposome detection reagent is then coupled to a biotin-labeled second antibody through a NeutrAvidin bridge. The liposome is ruptured to release the reporter DNA, which serves as a surrogate to quantify the protein target using real-time PCR. Results A liposome detection reagent was prepared, which consisted of a population of liposomes ~120 nm in diameter with each liposome possessing ~800 accessible biotin receptors and ~220 encapsulated reporters. This liposome detection reagent was used in an assay to quantify the concentration of carcinoembryonic antigen (CEA in human serum. This ILPCR assay exhibited a linear dose–response curve from 10-10 M to 10-16 M CEA. Within this range the assay coefficient of variance was Conclusions The ILPCR assay has several advantages over other immuno-PCR methods. The reporter DNA and biotin-labeled PEG phospholipids spontaneously incorporate into the liposomes as they form, simplifying preparation of the detection reagent. Encapsulation of the reporter inside the liposomes allows nonspecific DNA in the assay medium to be degraded with DNase I prior to quantification of the encapsulated reporter by PCR, which reduces false-positive results and improves quantitative accuracy. The ability to

  13. [Comparison and evaluation of the Binax EIA and Biotest EIA urinary antigen kits for detection of Legionella pneumophila antigen in urine samples].

    Science.gov (United States)

    Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek

    2011-01-01

    The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.

  14. Radioimmunoassay in the detection of the hepatitis Be antigen/antibody system in asymptomatic carriers of hepatitis B surface antigen

    International Nuclear Information System (INIS)

    Pastore, G.; Dentico, P.; Angarano, G.; Schiraldi, O.; Zanetti, A.R.; Ferroni, P.

    1980-01-01

    A radioimmunoassay for hepatitis e antigen (HBeAg) and antibody to e (anti-HBe) was developed and sera of 71 asymptomatic chronic carriers of hepatitis B surface antigen (HBsAg), in 44 of whom liver biopsy was obtained, were tested. In addition, testing for Dane particle associated DNA polymerase activity was performed in all sera. HBeAg was detected in 14 subjects (19.7%) and anti-HBe in 46 (64.8%). The highest proportion of HBeAg positivity (40%) was found among carriers with histological evidence of chronic hepatitis, whereas anti-HBe was present in 80% of carriers with normal liver histology, in 58% of carriers with non-specific reactive hepatitis and in 60% of carriers with chronic liver lesions. DNA polymerase activity was present in 92.8% of sera positive for HBeAg, in 13% of sera positive for anti HBe, and in 9% of sera negative for both markers. Our results demonstrate that not all HBsAg carriers reactive to HBeAg show evidence of chronic hepatitis nor, conversely, that anti-HBe is invariably associated with the healthy carrier state of HBsAg. Finally, circulating Dane particles, as revealed by the presence of serum specific DNA polymerase activity, may also be present in anti-HBe positive sera other than those of some HBsAg carriers lacking both HBeAg and anti-HBe. (orig.) [de

  15. Detection of avian influenza antigens in proximity fiber, droplet, and optical waveguide microfluidics

    Science.gov (United States)

    Yoon, Jeong-Yeol; Heinze, Brian C.; Gamboa, Jessica; You, David J.

    2009-05-01

    Virus antigens of avian influenza subtype H3N2 were detected on two different microfluidic platforms: microchannel and droplet. Latex immunoagglutination assays were performed using 920-nm highly carboxylated polystyrene beads that are conjugated with antibody to avian influenza virus. The bead suspension was merged with the solutions of avian influenza virus antigens in a Y-junction of a microchannel made by polydimethylsiloxane soft lithography. The resulting latex immunoagglutinations were measured with two optical fibers in proximity setup to detect 45° forward light scattering. Alternatively, 10 μL droplets of a bead suspension and an antigen solution were merged on a superhydrophobic surface (water contact angle = 155°), whose movement was guided by a metal wire, and 180° back light scattering is measured with a backscattering optical probe. Detection limits were 0.1 pg mL-1 for both microchannel with proximity fibers and droplet microfluidics, thanks to the use of micro-positioning stages to help generate reproducible optical signals. Additionally, optical waveguide was tested by constructing optical waveguide channels (filled with mineral oil) within a microfluidic device to detect the same light scattering. Detection limit was 0.1 ng mL-1 for an optical waveguide device, with a strong potential of improvement in the near future. The use of optical waveguide enabled smaller device setup, easier operation, smaller standard deviations and broader linear range of assay than proximity fiber microchannel and droplet microfluidics. Total assay time was less than 10 min.

  16. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    OpenAIRE

    Alderete, J F

    1984-01-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses durin...

  17. Comparison of Excretory-Secretory and Somatic Antigens of Ornithobilharzia turkestanicum in Agar Gel Diffusion Test

    Directory of Open Access Journals (Sweden)

    H Miranzadeh

    2008-12-01

    Full Text Available Background: Ornithobilharziosis as one of the parasitic infections may give rise to serious economic problems in animal husbandry. The Aim of the study was to prepare and compare the somatic and excretory-secretory (ES antigens of O. tur­kestanicum in gel diffusion test. Methods: Excretory-secretory (ES and somatic antigens of Ornithobilharzia turkestanicum were prepared from collected worms from mesentric blood vessels of infected sheep. The laboratory bred rabbits were immunized with antigens and then antisera were prepared. The reaction of antigens and antisera was observed in gel diffusion test. Results: ES antigens of this species showed positive reaction with antisera raised against ES and also somatic antigens. Somatic antigens also showed positive reaction with antisera raised against somatic and also ES antigens. Conclusion: The antigenicity of O. turkestanicum ES and somatic antigens is the same in gel diffusion test.

  18. Detection and Characterization of Autoantibodies to Neuronal Cell-Surface Antigens in the Central Nervous System

    Directory of Open Access Journals (Sweden)

    Marleen eVan Coevorden-Hameete

    2016-05-01

    Full Text Available Autoimmune encephalitis (AIE is a group of disorders in which autoantibodies directed at antigens located on the plasma membrane of neurons induce severe neurological symptoms. In contrast to classical paraneoplastic disorders, AIE patients respond well to immunotherapy. The detection of neuronal surface autoantibodies in patients’ serum or CSF therefore has serious consequences for the patients’ treatment and follow-up and requires the availability of sensitive and specific diagnostic tests. This mini-review provides a guideline for both diagnostic and research laboratories that work on the detection of known surface autoantibodies and/or the identification of novel surface antigens. We discuss the strengths and pitfalls of different techniques for anti-neuronal antibody detection: 1 Immunohistochemistry and immunofluorescence on rat/ primate brain sections, 2 Immunocytochemistry of living cultured hippocampal neurons, 3 Cell Based Assay (CBA. In addition, we discuss the use of immunoprecipitation and mass spectrometry analysis for the detection of novel neuronal surface antigens, which is a crucial step in further disease classification and the development of novel CBAs.

  19. Detection of proliferating cell nuclear antigens and interleukin-2 beta receptor molecules on mitogen- and antigen-stimulated lymphocytes.

    Science.gov (United States)

    Hesketh, J; Dobbelaere, D; Griffin, J F; Buchan, G

    1993-01-01

    The expression of interleukin-2 receptors (IL-2R) and proliferating cell nuclear antigens (PCNA) were compared for their usefulness as markers of lymphocyte activation. Heterologous polyclonal (anti-bovine IL-2R) and monoclonal (anti-human PCNA) antibodies were used to detect the expression of these molecules on activated deer lymphocytes. Both molecules were co-expressed on blast cells which had been activated with mitogen [concanavalin A (Con A)]. There was detectable up-regulation of IL-2R expression in response to antigen [Mycobacterium bovis-derived purified protein derivative (PPD)] stimulation while PCNA expression mimicked lymphocyte transformation (LT) reactivity. PCNA expression was found to more accurately reflect both antigen- and mitogen-activated lymphocyte activation, as estimated by LT activity. The expression of PCNA was used to identify antigen reactive cells from animals exposed to M. bovis. A very low percentage (1.1 +/- 0.4%) of peripheral blood lymphocytes from non-infected animals could be stimulated to express PCNA by in vitro culture with antigen (PPD). Within the infected group both diseased and healthy, 'in-contact', animals expressed significantly higher levels of PCNA upon antigen stimulation. PMID:8104884

  20. Investigation of contactless detection using a giant magnetoresistance sensor for detecting prostate specific antigen.

    Science.gov (United States)

    Sun, Xuecheng; Zhi, Shaotao; Lei, Chong; Zhou, Yong

    2016-08-01

    This paper presents a contactless detection method for detecting prostate specific antigen with a giant magnetoresistance sensor. In contactless detection case, the prostate specific antigen sample preparation was separated from the sensor that prevented the sensor from being immersed in chemical solvents, and made the sensor implementing in immediately reuse without wash. Experimental results showed that applied an external magnetic field in a range of 50 Oe to 90 Oe, Dynabeads with a concentration as low as 0.1 μg/mL can be detected by this system and could give an approximate quantitation to the logarithmic of Dynabeads concentration. Sandwich immunoassay was employed for preparing PSA samples. The PSA capture was implemented on a gold film modified with a self-assembled monolayer and using biotinylated secondary antibody against PSA and streptavidinylated Dynabeads. With DC magnetic field in the range of 50 to 90 Oe, PSA can be detected with a detection limit as low as 0.1 ng/mL. Samples spiked with different concentrations of PSA can be distinguished clearly. Due to the contactless detection method, the detection system exhibited advantages such as convenient manipulation, reusable, inexpensive, small weight. So, this detection method was a promising candidate in biomarker detection, especially in point of care detection.

  1. Detection of different categories of hepatitis B virus (HBV) infection in a multi-regional study comparing the clinical sensitivity of hepatitis B surface antigen and HBV-DNA testing

    DEFF Research Database (Denmark)

    Lelie, Nico; Bruhn, Roberta; Busch, Michael

    2017-01-01

    BACKGROUND: Twenty-two users of individual donation nucleic acid amplification technology (ID-NAT) in six geographical regions provided detailed hepatitis B virus (HBV) infection data in first-time, lapsed, and repeat donations and classified confirmed HBV-positive donors into different infection...... categories. These data were used to compare the clinical sensitivity of hepatitis B surface antigen (HBsAg) and HBV-DNA testing. STUDY DESIGN AND METHODS: In total 10,981,776 donations from South Africa, Egypt, the Mediterranean, North and Central Europe, South East Asia, and Oceania were screened for HBV...

  2. THE ANTIGEN-SPECIFIC CELL IN VITRO TESTS FOR POST-VACCINATION ANTIPLAGUE IMMUNITY FORMATION

    Directory of Open Access Journals (Sweden)

    A. N. Kulichenko

    2017-01-01

    Full Text Available The possibility of post-vaccination anti-plague immunity evaluation was researched using antigen-stimulated cells tests in vitro and cytometry analysis. The object of study — the blood samples of 17 people immunised by the live plague vaccine (Yersinia pestis EV epicutaneously. Blood taking was carried out before vaccination and after immunisation on 7 and on 21 days, in 3 and in 6 months. Intensity antigen reactivity of lymphocytes was detected by cell tests in vitro, analysing markers of early (CD45+CD3+CD25+ and late (CD45+CD3+HLA-DR+ lymphocyte activation using flow cytometry. The complex of water-soluble Y. pestis antigens and allergen — pestin PP was tested as antigen. The high stimulating potential was defined of the water-soluble antigens Y. pestis complex. It is shown that coefficient of stimulation of relative level T- lymphocytes which express receptors for IL-2 was positive for all observation times after immunisation. The coefficient of stimulation had maximum values at 21 days (56.37% and at 3 (47.41% months. In identifying HLADR-positive lymphocytes before vaccination, the negative coefficient of stimulation was indicated on 7 and 21 days and the positive coefficient of stimulation was indicated at 3 and at 6 months. Analysis of intensity expression of early and late lymphocyte activation markers dynamics showed the possibility and prospect of application of cellular in vitro tests for the laboratory evaluation of specific reactivity of cellular immunity in both the early (7 days and late (6 months periods after vaccination. The results can be the basis for developing a new algorithm for assessment of immunological effectiveness of vaccination people against plague. It is the algorithm based on the identification of lymphocyte activation markers by antigen stimulation in conditions in vitro.

  3. The sensitivity and the specifity of rapid antigen test in streptococcal upper respiratory tract infections.

    Science.gov (United States)

    Gurol, Yesim; Akan, Hulya; Izbirak, Guldal; Tekkanat, Zuhal Tazegun; Gunduz, Tehlile Silem; Hayran, Osman; Yilmaz, Gulden

    2010-06-01

    It is aimed to detect the sensitivity and specificity of rapid antigen detection of group A beta hemolytic streptococci from throat specimen compared with throat culture. The other goal of the study is to help in giving clinical decisions in upper respiratory tract infections according to the age group, by detection of sensitivity and positive predictive values of the rapid tests and throat cultures. Rapid antigen detection and throat culture results for group A beta hemolytic streptococci from outpatients attending to our university hospital between the first of November 2005 and 31st of December 2008 were evaluated retrospectively. Throat samples were obtained by swabs from the throat and transported in the Stuart medium and Quickvue Strep A [Quidel, San Diego, USA] cassette test was applied and for culture, specimen was inoculated on 5% blood sheep agar and identified according to bacitracin and trimethoprim-sulphametaxazole susceptibility from beta hemolytic colonies. During the dates between the first of November 2005 and 31st of December 2008, from 453 patients both rapid antigen detection and throat culture were evaluated. Rapid antigen detection sensitivity and specificity were found to be 64.6% and 96.79%, respectively. The positive predictive value was 80.95% whereas negative predictive value was 92.82%. Kappa index was 0.91. When the results were evaluated according to the age groups, the sensitivity and the positive predictive value of rapid antigen detection in children were 70%, 90.3% and in adults 59.4%, 70.4%. When bacterial infection is concerned to prevent unnecessary antibiotic use, rapid streptococcal antigen test (RSAT) is a reliable method to begin immediate treatment. To get the maximum sensitivity of RSAT, the specimen collection technique used and education of the health care workers is important. While giving clinical decision, it must be taken into consideration that the sensitivity and the positive predictive value of the RSAT is quite

  4. Detection of hepatitis B surface antigen by solid phase radioimmunoassay and immunometric assay (using enhanced luminescence)

    International Nuclear Information System (INIS)

    Nicholson, S.; Efandis, T.; Gust, I.

    1991-01-01

    A study was performed to assess the sensitivity and specificity of the amerlite monoclonal immunoassay for detection of hepatitis B surface antigen (HBsAG) by comparison with the Abbott Ausria II radioimmunoassay (RI). Serial bleeds from 34 patients with acute or chronic hepatitis B were tested by both assays. The Abbott Ausria II assay detected HBsAG longer than the Amersham Amerlite assay on two occasions and earlier on one occasion. Twelve patients with low HBsAg positive results (confirmed by Ausria II) were tested by the Amerlite assay, four were repeatably positive, five repeatably negative and three gave borderline results (which on repeat testing were negative). A similar trend was seen when a panel of sera containing known concentrations of HBsAG was tested. Replicate testing of 10 specimens eight times showed very good reproducibility by the Amerlite assay. Overall, the specificity of both assays was comparable, however differences in sensitivity were observed. 3 tabs

  5. Detection of hMPV antigen by EIA in clinical specimens.

    Science.gov (United States)

    Pancer, Katarzyna; Ciaćka, Agnieszka; Gut, Włodzimierz; Lipka, Bozena; Mierzejewska, Justyna; Milewska-Bobula, Bogumiła; Smorczewska-Kiljan, Anna; Jahnz-Rózyk, Karina; Litwińska, Bogumiła

    2011-01-01

    Human Metapneumovirus (hMPV) is one of the latest discovered viruses. It has been classified to Paramyxoviridae family. It is the second viral etiological agent, after RSV, which causes respiratory tract infections (RTI) in children, especially children below 5 years old. It is estimated that 5-25% of RTI in children is due to hMPV. In adults hMPV reinfections are bounded to upper respiratory tract infections. The aim of the study was to establish usefulness of ELISA test in detecting hMPV antigen and to analyze hMPV infection in connection to clinical diagnosis. 273 nasopharyngeal swabs from children (189 swabs) and adults (84 swabs) with respiratory tract infections collected from 2008 to 2010 were examined. Due to similarity of hMPV and RSV viruses and overlapping of their epidemic season rapid immunochromatographic test for RSV antigen detection was also performed in case of 120 samples, hMPV antigen was detected in 24.5% of all swabs (n = 67): in 0.0% probes in 2008, 29.0% in 2009 and 36.8% in first quarter of 2010. The highest rate ofhMPV infection was detected from summer of 2009 till the end of March 2010 (VIII-IX 2009 - 62.5%, X-XII 2009 - 44.1% and I-III 2010 -36.8%). We analyzed respiratory tract diseases reported in patients with hMPV infection. Infection due to hMPV was found in 26.5% of children and 24.0% of adults with recognized pneumonia, respectively in 28.4 and 17.6% of patients with bronchitis. Bronchiolitis was diagnosed in two children with hMPV. RSV and hMPV coinfections were confirmed in 15 out of 120 examined probes. Cross reaction pattern was excluded thanks to ELISA hMPV antigen test which was performed with suspension of RSV and thanks to statistical analysis. Coinfections were confirmed in 8% of pneumonia, 11% of bronchitis and 24.2% of the rest concomitant diagnoses. We found hMPV infection as the significant agent ofpneumonia not only in children but also in adults. ELISA hMPV antigen test can be used in diagnosis of etiological agent

  6. The accuracy of the Helicobacter pylori stool antigen test in diagnosing H-pylori in treated and untreated patients

    NARCIS (Netherlands)

    Arents, NL; van Zwet, AA; Thijs, JC; de Jong, A; Pool, MO; Kleibeuker, JH

    Objective and design To evaluate the performance of the Helicobacter pylori stool antigen test (HpSA test) in detecting H. pylori infection and monitoring the effect of treatment. This was done in two separate studies using either a biopsy or the C-13-urea breath test based 'gold standard' (in

  7. Detection of avian influenza antibodies and antigens in poultry and ...

    African Journals Online (AJOL)

    Using HI test, the wild birds were negative for AI (H5) antibodies but ELISA detected AI (NP) antibodies in Black Stork (Ciconia nigra) with an overall seroprevalence of 4.5% and mean titre of 24.50±2.400 EU. Cloacal swabs from the same species of wild birds that were tested for antibodies and 710 oropharyngeal swabs ...

  8. A Model System for Concurrent Detection of Antigen and Antibody Based on Immunological Fluorescent Method

    Directory of Open Access Journals (Sweden)

    Yuan-Cheng Cao

    2015-01-01

    Full Text Available This paper describes a combined antigen/antibody immunoassay implemented in a 96-well plate using fluorescent spectroscopic method. First, goat anti-human IgG was used to capture human IgG (model antigen; goat anti-human IgG (Cy3 or FITC was used to detect the model antigen; a saturating level of model antigen was then added followed by unlabelled goat anti-human IgG (model antibody; finally, Cy3 labelled rabbit anti-goat IgG was used to detect the model antibody. Two approaches were applied to the concomitant assay to analyze the feasibility. The first approach applied FITC and Cy3 when both targets were present at the same time, resulting in 50 ng/mL of the antibody detection limit and 10 ng/mL of antigen detection limit in the quantitative measurements of target concentration, taking the consideration of FRET efficiency of 68% between donor and acceptor. The sequential approach tended to lower the signal/noise (S/N ratio and the detection of the model antigen (lower than 1 ng/mL had better sensitivity than the model antibody (lower than 50 ng/mL. This combined antigen/antibody method might be useful for combined detection of antigens and antibodies. It will be helpful to screen for both antigen and antibody particularly in the situations of the multiserotype and high-frequency mutant virus infections.

  9. Simultaneous detection of Hepatitis B surface antigen and its antibody by radioimmunoassay

    International Nuclear Information System (INIS)

    Crouzat-Reynes, Gerard; Perigois, Francois; Lecureuil, Michel; Lejeune, Bernard

    1981-01-01

    The authors describe an original radioimmunoassay which allows the simultaneous detection of hepatitis B surface antigen and its antibody in a biological sample. Antigen and antibody are indiscriminately detected in a first step and then distinguished in a second step using the same reagents [fr

  10. RAPID DETECTION OF PNEUMOCOCCAL ANTIGEN IN PLEURAL FLUID OF PATIENTS WITH COMMUNITY ACQUIRED PNEUMONIA

    NARCIS (Netherlands)

    BOERSMA, WG; LOWENBERG, A; HOLLOWAY, Y; KUTTSCHRUTTER, H; SNIJDER, JAM; KOETER, GH

    Background Detection of pneumococcal antigen may help to increase the rate of diagnosis of pneumococcal pneumonia. This study was designed to determine the value of rapid detection of pneumococcal antigen in pleural fluid from patients with community acquired pneumonia. Methods Thoracentesis was

  11. A Highly Sensitive Rapid Diagnostic Test for Chagas Disease That Utilizes a Recombinant Trypanosoma cruzi Antigen

    Science.gov (United States)

    Barfield, C. A.; Barney, R. S.; Crudder, C. H.; Wilmoth, J. L.; Stevens, D. S.; Mora-Garcia, S.; Yanovsky, M. J.; Weigl, B. H.; Yanovsky, J.

    2011-01-01

    Improved diagnostic tests for Chagas disease are urgently needed. A new lateral flow rapid test for Chagas disease is under development at PATH, in collaboration with Laboratorio Lemos of Argentina, which utilizes a recombinant antigen for detection of antibodies to Trypanosoma cruzi. To evaluate the performance of this test, 375 earlier characterized serum specimens from a region where Chagas is endemic were tested using a reference test (the Ortho T. cruzi ELISA, Johnson & Johnson), a commercially available rapid test (Chagas STAT-PAK, Chembio), and the PATH–Lemos rapid test. Compared to the composite reference tests, the PATH–Lemos rapid test demonstrated an optimal sensitivity of 99.5% and specificity of 96.8%, while the Chagas STAT-PAK demonstrated a sensitivity of 95.3% and specificity of 99.5%. These results indicate that the PATH–Lemos rapid test shows promise as an improved and reliable tool for screening and diagnosis of Chagas disease. PMID:21342808

  12. Lymphocyte proliferation to mycobacterial antigens is detectable across a spectrum of HIV-associated tuberculosis

    Directory of Open Access Journals (Sweden)

    Bakari Muhammad

    2009-02-01

    Full Text Available Abstract Background Identifying novel TB diagnostics is a major public health priority. We explored the diagnostic characteristics of antimycobacterial lymphocyte proliferation assays (LPA in HIV-infected subjects with latent or active TB. Methods HIV-infected subjects with bacille Calmette Guérin (BCG scars and CD4 counts ≥ 200 cells/mm3 entering a TB booster vaccine trial in Tanzania had baseline in vivo and in vitro immune tests performed: tuberculin skin tests (TST, LPA and five day assays of interferon gamma (IFN-γ release. Assay antigens were early secreted antigenic target 6 (ESAT-6, antigen 85 (Ag85, and Mycobacterium tuberculosis whole cell lysate (WCL. Subjects were screened for active TB at enrollment by history, exam, sputum smear and culture. We compared antimycobacterial immune responses between subjects with and without latent or active TB at enrollment. Results Among 1885 subjects screened, 635 had latent TB and 13 had active TB. Subjects with latent TB were more likely than subjects without TB to have LPA responses to ESAT-6 (13.2% vs. 5.5%, P Conclusion Lymphoproliferative responses to mycobacteria are detectable during HIV-associated active TB, and are less sensitive but more specific than TST. Trial registration ClinicalTrials.gov Identifier NCT00052195.

  13. Accuracy of PfHRP2 versus Pf-pLDH antigen detection by malaria rapid diagnostic tests in hospitalized children in a seasonal hyperendemic malaria transmission area in Burkina Faso

    OpenAIRE

    Maltha, Jessica; Guiraud, Issa; Lompo, Palpouguini; Kaboré, Bérenger; Gillet, Philippe; Van Geet, Chris; Tinto, Halidou; Jacobs, Jan

    2014-01-01

    Background In most sub-Saharan African countries malaria rapid diagnostic tests (RDTs) are now used for the diagnosis of malaria. Most RDTs used detect Plasmodium falciparum histidine-rich protein-2 (PfHRP2), though P. falciparum-specific parasite lactate dehydrogenase (Pf-pLDH)-detecting RDTs may have advantages over PfHRP2-detecting RDTs. Only few data are available on the use of RDTs in severe illness and the present study compared Pf-pLDH to PfHRP2-detection. Methods Hospitalized children...

  14. Detection of viral antigens by solid phase radioimmunoassay on polyethylene film

    Energy Technology Data Exchange (ETDEWEB)

    Prokudina, E N; Semenova, N P; Zhdanov, V M

    1986-04-01

    Polyethylene film, without any pretreatment, may serve as a solid phase (SP) for RIA. Viral antigens (HBsAg, and influenza virus) are detected by SP-RIA on the film with a sensitivity of about 2-3 ng/ml or 40-60 pg/assay. The use of polyethylene film allows one to record RIA autographically. The use of micro amounts of reagents and specimens tested is an added advantage. No special equipment is necessary, the method is inexpensive, easy to perform and may be used for mass screening. (Auth.). 7 refs.; 4 figs.

  15. Sensitivity, Specificity, and Positivity Predictors of the Pneumococcal Urinary Antigen Test in Community-Acquired Pneumonia.

    Science.gov (United States)

    Molinos, Luis; Zalacain, Rafael; Menéndez, Rosario; Reyes, Soledad; Capelastegui, Alberto; Cillóniz, Catia; Rajas, Olga; Borderías, Luis; Martín-Villasclaras, Juan J; Bello, Salvador; Alfageme, Inmaculada; Rodríguez de Castro, Felipe; Rello, Jordi; Ruiz-Manzano, Juan; Gabarrús, Albert; Musher, Daniel M; Torres, Antoni

    2015-10-01

    Detection of the C-polysaccharide of Streptococcus pneumoniae in urine by an immune-chromatographic test is increasingly used to evaluate patients with community-acquired pneumonia. We assessed the sensitivity and specificity of this test in the largest series of cases to date and used logistic regression models to determine predictors of positivity in patients hospitalized with community-acquired pneumonia. We performed a multicenter, prospective, observational study of 4,374 patients hospitalized with community-acquired pneumonia. The urinary antigen test was done in 3,874 cases. Pneumococcal infection was diagnosed in 916 cases (21%); 653 (71%) of these cases were diagnosed exclusively by the urinary antigen test. Sensitivity and specificity were 60 and 99.7%, respectively. Predictors of urinary antigen positivity were female sex; heart rate≥125 bpm, systolic blood pressureantibiotic treatment; pleuritic chest pain; chills; pleural effusion; and blood urea nitrogen≥30 mg/dl. With at least six of all these predictors present, the probability of positivity was 52%. With only one factor present, the probability was only 12%. The urinary antigen test is a method with good sensitivity and excellent specificity in diagnosing pneumococcal pneumonia, and its use greatly increased the recognition of community-acquired pneumonia due to S. pneumoniae. With a specificity of 99.7%, this test could be used to direct simplified antibiotic therapy, thereby avoiding excess costs and risk for bacterial resistance that result from broad-spectrum antibiotics. We also identified predictors of positivity that could increase suspicion for pneumococcal infection or avoid the unnecessary use of this test.

  16. A novel one-step Helicobacter pylori saliva antigen test.

    Science.gov (United States)

    Yang, Bi-Ling; Yeh, Chun; Kwong, Wei-Gang; Lee, Shou-Dong

    2015-02-01

    A rapid, reliable, and sufficiently accurate test for diagnosing Helicobacter pylori infection is required for screening dyspeptic patients before a referral for endoscopy. The purpose of this article is two-fold: first, to evaluate the accuracy of a one-step H. pylori saliva antigen (HPS) test; and second, to compare noninvasive and invasive H. pylori tests in Taiwanese population. A total of 104 consecutive dyspeptic patients admitted for gastroenterology into the outpatient department underwent a one-step HPS test, rapid urease test, histology, and (13)C-urea breath test (13)C-UBT (proto C-13 urea kit). The accuracy of the HPS test was compared with a gold standard defined by at least two positive H. pylori test results from three H. pylori tests (histology, rapid urease test, and (13)C-UBT). The 104 patients eligible for analysis (mean age: 58 years, range 22-87 years), 21 (20%) were gold standard positive. Among them, the positive of the one-step H. pylori saliva Ag test, rapid urease test, (13)C-UBT, histology were (52; 50%), (17; 16%), (27; 25%) and (22; 21%) respectively. The sensitivity and specificity of the HPS tests, rapid urease test, (13)C-UBTs, and histology were 71.43% and 55.42%, 76.19% and 98.80%, 100% and 92.77%, and 85.71% and 95.18%, respectively, relative to the gold standard. The one-step HPS test exhibited a sensitivity of 71.43%, nearly equivalent to that of the rapid urea test. The one-step HPS test exhibited a high sensitivity and low specificity compared with the other tests, indicating that it is not sufficiently accurate for use in a clinical setting for diagnosing H. pylori infection. However, the test is simple to use (requiring only a saliva sample), inexpensive, and noninvasive in its application, and thus appealing for use in population-based prevalence surveys of the epidemiology of H. pylori infection. Copyright © 2014. Published by Elsevier Taiwan.

  17. Detection of Burkholderia pseudomallei O-antigen serotypes in near-neighbor species

    Directory of Open Access Journals (Sweden)

    Stone Joshua K

    2012-11-01

    Full Text Available Abstract Background Burkholderia pseudomallei is the etiological agent of melioidosis and a CDC category B select agent with no available effective vaccine. Previous immunizations in mice have utilized the lipopolysaccharide (LPS as a potential vaccine target because it is known as one of the most important antigenic epitopes in B. pseudomallei. Complicating this strategy are the four different B. pseudomallei LPS O-antigen types: A, B, B2, and rough. Sero-crossreactivity is common among O-antigens of Burkholderia species. Here, we identified the presence of multiple B. pseudomallei O-antigen types and sero-crossreactivity in its near-neighbor species. Results PCR screening of O-antigen biosynthesis genes, phenotypic characterization using SDS-PAGE, and immunoblot analysis showed that majority of B. mallei and B. thailandensis strains contained the typical O-antigen type A. In contrast, most of B. ubonensis and B. thailandensis-like strains expressed the atypical O-antigen types B and B2, respectively. Most B. oklahomensis strains expressed a distinct and non-seroreactive O-antigen type, except strain E0147 which expressed O-antigen type A. O-antigen type B2 was also detected in B. thailandensis 82172, B. ubonensis MSMB108, and Burkholderia sp. MSMB175. Interestingly, B. thailandensis-like MSMB43 contained a novel serotype B positive O-antigen. Conclusions This study expands the number of species which express B. pseudomallei O-antigen types. Further work is required to elucidate the full structures and how closely these are to the B. pseudomallei O-antigens, which will ultimately determine the efficacy of the near-neighbor B serotypes for vaccine development.

  18. Screening for prostate cancer with the prostate-specific antigen test: are patients making informed decisions?

    Science.gov (United States)

    O'Dell, K J; Volk, R J; Cass, A R; Spann, S J

    1999-09-01

    The benefits of early detection of prostate cancer are uncertain, and the American College of Physicians and the American Academy of Family Physicians recommend individual decision making in prostate cancer screening. This study reports the knowledge of male primary care patients about prostate cancer and prostate-specific antigen (PSA) testing and examines how that knowledge is related to PSA testing, preferences for testing in the future, and desire for involvement in physician-patient decision making. The sample included 160 men aged 45 to 70 years with no history of prostate cancer who presented for care at a university-based family medicine clinic. Before scheduled office visits, patients completed a questionnaire developed for this study that included a 10-question measure of prostate cancer knowledge, the Deber-Kraestchmer Problem-Solving Decision-Making Scale, sociodemographic indicators, and questions on PSA testing. In general, patients who were college graduates were more knowledgeable about prostate cancer and early detection than those with a high school education or less. Aside from college graduates, most patients could not identify the principle advantages and disadvantages of PSA testing. Patients indicating previous or future plans for PSA testing demonstrated greater knowledge than other patients. Desire for involvement in decision making varied by patient education but was not related to past PSA testing. Patients lack knowledge about prostate cancer and early detection. This knowledge deficit may impede the early detection of prostate cancer and is a barrier to making an informed decision about undergoing PSA testing.

  19. A comparative study of blood smear, QBC and antigen detection for diagnosis of malaria.

    Science.gov (United States)

    Parija, S C; Dhodapkar, Rahul; Elangovan, Subashini; Chaya, D R

    2009-01-01

    Rapid diagnosis is prerequisite for effective treatment and reducing mortality and morbidity of malaria. This study was taken up to compare the efficacy of various methods available, i.e., thick and thin smear, quantitative buffy coat (QBC), plasmodium lactate dehydrogenase and aldolase in blood of patient. A total of 411 samples were collected from patients presenting with classic symptoms of malaria. For traditional microscopy; thick and thin smears were prepared and stained with Leishman's stain, taking thick smear as gold standard, thin smear had a sensitivity and specificity of 54.8% and 100%, respectively. QBC and antigen detection was done using commercially available kits; out of 411 samples, QBC and Malariagen were positive in 66 and 62 cases, with a sensitivity of 78% and 75%, respectively. Leishman's thick smear, although cost effective, is difficult to interpret for inexperienced microscopists; so if facilities are available, QBC should be used for routine diagnosis. In places where facilities are not available, rapid, simple and easy to interpret antigen detection test can be used despite low sensitivity.

  20. A comparative study of blood smear, QBC and antigen detection for diagnosis of malaria

    Directory of Open Access Journals (Sweden)

    Parija S

    2009-04-01

    Full Text Available Rapid diagnosis is prerequisite for effective treatment and reducing mortality and morbidity of malaria. This study was taken up to compare the efficacy of various methods available, i.e., thick and thin smear, quantitative buffy coat (QBC, plasmodium lactate dehydrogenase and aldolase in blood of patient. A total of 411 samples were collected from patients presenting with classic symptoms of malaria. For traditional microscopy; thick and thin smears were prepared and stained with Leishman′s stain, taking thick smear as gold standard, thin smear had a sensitivity and specificity of 54.8% and 100%, respectively. QBC and antigen detection was done using commercially available kits; out of 411 samples, QBC and Malariagen were positive in 66 and 62 cases, with a sensitivity of 78% and 75%, respectively. Leishman′s thick smear, although cost effective, is difficult to interpret for inexperienced microscopists; so if facilities are available, QBC should be used for routine diagnosis. In places where facilities are not available, rapid, simple and easy to interpret antigen detection test can be used despite low sensitivity.

  1. Improving dengue viral antigens detection in dengue patient serum specimens using a low pH glycine buffer treatment.

    Science.gov (United States)

    Shen, Wen-Fan; Galula, Jedhan Ucat; Chang, Gwong-Jen J; Wu, Han-Chung; King, Chwan-Chuen; Chao, Day-Yu

    2017-04-01

    Early diagnosis of dengue virus (DENV) infection to monitor the potential progression to hemorrhagic fever can influence the timely management of dengue-associated severe illness. Nonstructural protein 1 (NS1) antigen detection in acute serum specimens has been widely accepted as an early diagnostic assay for dengue infection; however, lower sensitivity of the NS1 antigen-capture enzyme-linked immunosorbent assay (Ag-ELISA) in secondary dengue viral infection has been reported. In this study, we developed two forms of Ag-ELISA capable of detecting E-Ag containing virion and virus-like particles, and secreted NS1 (sNS1) antigens, respectively. The temporal kinetics of viral RNA, sNS1, and E-Ag were evaluated based on the in vitro infection experiment. Meanwhile, a panel of 62 DENV-2 infected patients' sera was tested. The sensitivity was 3.042 ng/mL and 3.840 ng/mL for sNS1 and E, respectively. The temporal kinetics of the appearance of viral RNA, E, NS1, and infectious virus in virus-infected tissue culture media suggested that viral RNAs and NS1 antigens could be detected earlier than E-Ag and infectious virus. Furthermore, a panel of 62 sera from patients infected by DENV Serotype 2 was tested. Treating clinical specimens with the dissociation buffer increased the detectable level of E from 13% to 92% and NS1 antigens from 40% to 85%. Inclusion of a low-pH glycine buffer treatment step in the commercially available Ag-ELISA is crucial for clinical diagnosis and E-containing viral particles could be a valuable target for acute DENV diagnosis, similar to NS1 detection. Copyright © 2015. Published by Elsevier B.V.

  2. Method to conjugate polysaccharide antigens to surfaces for the detection of antibodies.

    Science.gov (United States)

    Boas, Ulrik; Lind, Peter; Riber, Ulla

    2014-11-15

    A new generic method for the conjugation of lipopolysaccharide (LPS)-derived polysaccharide antigens from gram-negative bacteria has been developed using Salmonella as a model. After removal of lipid A from the LPS by mild acidolysis, the polysaccharide antigen was conjugated to polystyrene microbeads modified with N-alkyl hydroxylamine and N-alkyl-O-methyl hydroxylamine surface groups by incubation of antigen and beads for 16 h at 40 °C without the need for coupling agents. The efficiency of the new method was evaluated by flow cytometry in model samples and serum samples containing antibodies against Salmonella typhimurium and Salmonella dublin. The presented method was compared with a similar method for conjugation of Salmonella polysaccharide antigens to surfaces. Here, the new method showed higher antigen coupling efficiency by detecting low concentrations of antibodies. Furthermore, the polysaccharide-conjugated beads showed preserved bioactivity after 1 year of use. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Jatobal virus antigenic characterization by ELISA and neutralization test using EIA as indicator, on tissue culture

    Directory of Open Access Journals (Sweden)

    Luiz Tadeu M. Figueiredo

    1988-06-01

    Full Text Available A virus antigenic characterization methodology using an indirect method of antibody detection ELISA with virus-infected cultured cells as antigen and a micro virus neutralisation test using EIA (NT-EIA as an aid to reading were used for antigenic characterization of Jatobal (BeAn 423380. Jatobal virus was characterized as a Bunyaviridae, Bunyavirus genus, Simbu serogroup virus. ELISA using infected cultured cells as antigen is a sensitive and reliable method for identification of viruses and has many advantages over conventional antibody capture ELISA's and other tests: it eliminates solid phase coating with virus and laborious antigen preparation; it permits screening of large numbers of virus antisera faster and more easily than by CF, HAI, or plaque reduction NT. ELISA and NT using EIA as an aid to reading can be applicable to viruses which do not produce cytopathogenic effect. Both techniques are applicable to identification of viruses which grow in mosquito cells.A caracterização antigênica do vírus Jatobal (BeAn 423380 foi efetuada utilizando uma técnica de ELISA para deteccão de anticorpos que utiliza culturas celulares infectadas como antígeno e um micro teste de neutralização para vírus que utiliza o método imunoenzimático como auxiliar para a leitura dos resultados (NT-EIA. O vírus Jatobal foi caracterizado como um Bunyaviridae, gênero Bunyavirus, pertencente ao sorogrupo Simbu. A técnica de ELISA, utilizando culturas celulares infectadas como antígeno, trata-se de método sensível e confiável na identificação de agentes virais, possuindo muitas vantagens sobre ELISA convencionais e outros testes: elimina a preparação laboriosa de antígenos para o revestimento em fase sólida; permite que se teste de forma mais rápida e fácil que por CF, HAI e neutralização por redução de plaques um grande número de antisoros de vírus. ELISA e NT-EIA podem ser utilizados para a classificação de vírus que não produzem

  4. Anti-Taenia solium monoclonal antibodies for the detection of parasite antigens in body fluids from patients with neurocysticercosis.

    Science.gov (United States)

    Paredes, Adriana; Sáenz, Patricia; Marzal, Miguel W; Orrego, Miguel A; Castillo, Yesenia; Rivera, Andrea; Mahanty, Siddhartha; Guerra-Giraldez, Cristina; García, Hector H; Nash, Theodore E

    2016-07-01

    Neurocysticercosis (NCC), an infection of the brain by Taenia solium (Ts) cysts, is the most common cause of adult-onset epilepsy in developing countries. Serological testing consists primarily of varying methods to detect antibodies in body fluids and more recently antigen (Ag) detection assays to identify individuals or animals with viable parasites. Antigen assays currently in use employ monoclonal antibodies (mAbs) raised against T. saginata, which have known cross reactivity to animal cestodes but are highly specific in human samples. We produced, characterized and tested 21 mAbs raised against T. solium whole cyst antigens, vesicular fluid or excretory secretory products. Reactivity of the TsmAbs against specific cyst structures was determined using immunofluorescence and immunohistochemistry on histological sections of Ts muscle cysts. Four TsmAbs reacted to vesicular space alone, 9 to the neck and cyst wall, one to the neck and vesicular space and 7 to the neck, cyst wall and vesicular space. An in-house ELISA assay to detect circulating Ts antigen, using the TsmAbs as capture antibodies and a rabbit polyclonal anti-Ts whole cyst antibody as a detector antibody demonstrated that eight of the 21 TsmAbs detected antigens in known NCC-positive human sera and three of these also in urine samples. Reactivity was expressed as normalized ratios of optical densities (OD positive control/OD negative control). Three TsmAbs had ratios >10 and five between 2 and 10. The TsmAbs have potential utility for the diagnosis and post-treatment monitoring of patients with viable NCC infections. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Development and Evaluation of a Rapid Antigen Detection and Serotyping Lateral Flow Antigen Detection System for Foot-and-Mouth Disease Virus.

    Directory of Open Access Journals (Sweden)

    Kazuki Morioka

    Full Text Available We developed a lateral flow strip using monoclonal antibodies (MAbs which allows for rapid antigen detection and serotyping of foot-and-mouth disease virus (FMDV. This FMDV serotyping strip was able to detect all 7 serotypes and distinguish serotypes O, A, C and Asia1. Its sensitivities ranged from 10(3 to 10(4 of a 50% tissue culture infectious dose of each FMDV stain; this is equal to those of the commercial product Svanodip (Boehringer Ingelheim Svanova, Uppsala, Sweden, which can detect all seven serotypes of FMDV, but does not distinguish them. Our evaluation of the FMDV serotyping strip using a total of 118 clinical samples (vesicular fluids, vesicular epithelial emulsions and oral and/or nasal swabs showed highly sensitive antigen detection and accuracy in serotyping in accordance with ELISA or RT-PCR. To the best of our knowledge, this is the first report on any FMDV serotyping strip that provides both rapid antigen detection and serotyping of FMDV at the same time on one strip without extra devices. This method will be useful in both FMD-free countries and FMD-infected countries, especially where laboratory diagnosis cannot be carried out.

  6. A novel approach for reliable detection of cathepsin S activities in mouse antigen presenting cells.

    Science.gov (United States)

    Steimle, Alex; Kalbacher, Hubert; Maurer, Andreas; Beifuss, Brigitte; Bender, Annika; Schäfer, Andrea; Müller, Ricarda; Autenrieth, Ingo B; Frick, Julia-Stefanie

    2016-05-01

    Cathepsin S (CTSS) is a eukaryotic protease mostly expressed in professional antigen presenting cells (APCs). Since CTSS activity regulation plays a role in the pathogenesis of various autoimmune diseases like multiple sclerosis, atherosclerosis, Sjögren's syndrome and psoriasis as well as in cancer progression, there is an ongoing interest in the reliable detection of cathepsin S activity. Various applications have been invented for specific detection of this enzyme. However, most of them have only been shown to be suitable for human samples, do not deliver quantitative results or the experimental procedure requires technical equipment that is not commonly available in a standard laboratory. We have tested a fluorogen substrate, Mca-GRWPPMGLPWE-Lys(Dnp)-DArg-NH2, that has been described to specifically detect CTSS activities in human APCs for its potential use for mouse samples. We have modified the protocol and thereby offer a cheap, easy, reproducible and quick activity assay to detect CTSS activities in mouse APCs. Since most of basic research on CTSS is performed in mice, this method closes a gap and offers a possibility for reliable and quantitative CTSS activity detection that can be performed in almost every laboratory. Copyright © 2016. Published by Elsevier B.V.

  7. Use of recombinant purified protein derivative (PPD) antigens as specific skin test for tuberculosis.

    Science.gov (United States)

    Stavri, Henriette; Bucurenci, Nadia; Ulea, Irina; Costache, Adriana; Popa, Loredana; Popa, Mircea Ioan

    2012-11-01

    Purified protein derivative (PPD) is currently the only available skin test reagent used worldwide for the diagnosis of tuberculosis (TB). The aim of this study was to develop a Mycobacterium tuberculosis specific skin test reagent, without false positive results due to Bacillus Calmette-Guerin (BCG) vaccination using recombinant antigens. Proteins in PPD IC-65 were analyzed by tandem mass spectrometry and compared to proteins in M. tuberculosis culture filtrate; 54 proteins were found in common. Top candidates MPT64, ESAT 6, and CFP 10 were overexpressed in Escherichia coli expression strains and purified as recombinant proteins. To formulate optimal immunodiagnostic PPD cocktails, the antigens were evaluated by skin testing guinea pigs sensitized with M. tuberculosis H37Rv and BCG. For single antigens and a cocktail mixture of these antigens, best results were obtained using 3 μg/0.1 ml, equivalent to 105 TU (tuberculin units). Each animal was simultaneously tested with PPD IC-65, 2 TU/0.1 ml, as reference. Reactivity of the multi-antigen cocktail was greater than that of any single antigen. The skin test results were between 34.3 and 76.6 per cent the level of reactivity compared to that of the reference when single antigens were tested and 124 per cent the level of reactivity compared to the reference for the multi-antigen cocktail. Our results showed that this specific cocktail could represent a potential candidate for a new skin diagnostic test for TB.

  8. Detection of Giardia duodenalis antigen in human fecal eluates by enzyme-linked immunosorbent assay using polyclonal antibodies

    Directory of Open Access Journals (Sweden)

    Sofía Duque-Beltrán

    2002-12-01

    Full Text Available The present study developed and standardized an enzime-linked immunosorbent assay (ELISA to detect Giardia antigen in feces using rabbit polyclonal antibodies. Giardia cysts were purified from human fecal samples by sucrose and percoll gradients. Gerbils (Meriones unguiculatus were infected to obtain trophozoites. Rabbits were inoculated with either cyst or trophozoite antigens of 14 Colombian Giardia isolates to develop antibodies against the respective stages. The IgG anti-Giardia were purified by sequential caprylic acid and ammonium sulfate precipitation. A portion of these polyclonal antibodies was linked to alkaline phosphatase (conjugate. One hundred and ninety six samples of human feces, from different patients, were tested by parasitologic diagnosis: 69 were positive for Giardia cysts, 56 had no Giardia parasites, and 71 revealed parasites other than Giardia. The optimal concentration of polyclonal antibodies for antigen capture was 40 µg/ml and the optimal conjugate dilution was 1:100. The absorbance cut-off value was 0.24. The parameters of the ELISA test for Giardia antigen detection were: sensitivity, 100% (95% CI: 93.4-100%; specificity, 95% (95% CI: 88.6-97.6%; positive predictive value, 91% (95% CI: 81.4-95.9%; and negative predictive value, 100% (95% CI: 96.1-100%. This ELISA will improve the diagnosis of Giardia infections in Colombia and will be useful in following patients after treatment.

  9. Detection of toxoplasma gondii antigens in sera from experimentally infected mice

    International Nuclear Information System (INIS)

    Shojaee, S.; Keshavarz, H.; Rezaian, M.; Mohebali, M.

    2007-01-01

    Detection of Toxoplasma antigen in serum of mice by Immunoblotting. strain. IgG isolated from rabbits that were immunized with T. gondii Immunoblotting was performed to detect T. gondii antigens in sera of mice. Serum samples from mice experimentally infected with T. gondii RH strain. The value of Immunoblotting in diagnosis of toxoplasmosis in acute stage of infection. The antigen bands detected in serum sample of mice were experimentally infected with T. gondii tachyzoite in immunoblotting. Six bands demonstrated on seventh post infection day six bands were identified. Similarly on sixth day four bands, on day five three bands and on fourth post infection day two bands were identified. No band was detected in control group sera. Immunoblotting is a sensitive method for diagnosis of acute stage of toxoplasmosis. (author)

  10. Prostate specific antigen velocity does not aid prostate cancer detection in men with prior negative biopsy.

    Science.gov (United States)

    Vickers, Andrew J; Wolters, Tineke; Savage, Caroline J; Cronin, Angel M; O'Brien, M Frank; Roobol, Monique J; Aus, Gunnar; Scardino, Peter T; Hugosson, Jonas; Schröder, Fritz H; Lilja, Hans

    2010-09-01

    Prostate specific antigen velocity has been proposed as a marker to aid in prostate cancer detection. We determined whether prostate specific antigen velocity could predict repeat biopsy results in men with persistently increased prostate specific antigen after initial negative biopsy. We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer and who underwent 1 or more subsequent prostate biopsies after an initial negative finding. We evaluated whether prostate specific antigen velocity improved predictive accuracy beyond that of prostate specific antigen alone. Of the 2,579 repeat biopsies 363 (14%) were positive for prostate cancer, of which 44 (1.7%) were high grade (Gleason score 7 or greater). Prostate specific antigen velocity was statistically associated with cancer risk but had low predictive accuracy (AUC 0.55, p <0.001). There was some evidence that prostate specific antigen velocity improved AUC compared to prostate specific antigen for high grade cancer. However, the small increase in risk associated with high prostate specific antigen velocity (from 1.7% to 2.8% as velocity increased from 0 to 1 ng/ml per year) had questionable clinical relevance. Men with prior negative biopsy are at lower risk for prostate cancer at subsequent biopsies with high grade disease particularly rare. We found little evidence to support prostate specific antigen velocity to aid in decisions about repeat biopsy for prostate cancer. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Shape anisotropy enhanced optomagnetic measurement for prostate-specific antigen detection via magnetic chain formation

    DEFF Research Database (Denmark)

    Tian, Bo; Wetterskog, Erik; Qiu, Zhen

    2017-01-01

    anisotropy), and directly increasing the optomagnetic signal (via optical shape anisotropy). We achieve a limit of detection (LOD) of 5.5 pM (0.82 ng/mL) for the detection of a model multivalent molecule, biotinylated anti-streptavidin, in PBS. For the measurements of prostate-specific antigen (PSA) in 50...

  12. Indirect solid-phase immunosorbent assay for detection of arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A [Institute of Poliomyelitis anU Viral Encephalities of the U.S.S.R. Academy of Medical Sciences, Moscow

    1984-05-01

    Indirect enzyme-linked immunosorbent assay (ELISA) and solid phase radioimmunoassay (SPRIA) using either enti-human or anti-mouse IgG labelled with horseradish peroxidase and /sup 125/I, respectively, were developed for the detection of Junin, Machupo, Tacaribe, Amapari, Tamiami, Lassa and LCM arenaviruses. Both methods allow high sensitivity detection of arenavirus antigens and antibodies.

  13. Radioimmunoassay for detecting antibodies against murine malarial parasite antigens: monoclonal antibodies recognizing Plasmodium yoelii antigens

    International Nuclear Information System (INIS)

    Kim, K.J.; Taylor, D.W.; Evans, C.B.; Asofsky, R.

    1980-01-01

    A solid-phase radioimmunoassay (SPRIA) in microtiter wells was established for detecting antibodies against Plasmodium yoelii Ag. The SPRIA was found (1) to require as little as 5 μg of crude parasite Ag per well, (2) to be able to detect 0.5 ng of monoclonal Ab, and (3) to be 10 4 times more sensitive than the indirect fluorescent Ab staining technique. In a modification of the above assay using intact RBC as an Ag, hyperimmune serum showed significant binding to the surface of erythrocytes of mice infected with P. yoelii parasites but not to RBC of normal mice. Hybridomas were prepared by fusing infected mouse spleen cells with myeloma cells. Using the SPRIA, hybrids secreting Ab against P. yoelii 17XL Ag were detected

  14. Evaluation of two reverse passive haemagglutination techniques and a solid-phase radioimmunoassay for detection of hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, H [Beijing Medical College (China); Coulepis, A G; Gust, I D [Fairfield Hospital for Communicable Diseases, Melbourne (Australia)

    1972-08-01

    The sensitivity and specificity of two commercially available reverse passive haemagglutination tests (Hepatest and Raphadex B) for the detection of hepatitis B surface antigen, were compared with the most widely used radioimmunoassay (Ausria II-125). A selected group of 282 sera were tested: these included the Australian hepatitis B reference panel, and a batch of 257 sera collected from patients with acute hepatitis B, chronic carriers of hepatitis B surface antigen and two populations in which hepatitis B virus infection is known to be endemic. The two reverse passive haemagglutination techniques were of comparable sensitivity but slightly less sensitive than radioimmunoassay. While radioimmunoassay still remains the test of choice for blood transfusion services, the reverse passive haemagglutination techniques are of great value for smaller laboratories and for field studies because of their longer shelf life, the absence of radioactive reagents and the lack of need to acquire a gammacounter.

  15. Novel antigens used to detect cell-mediated immune responses over time in Mycobacterium avium subsp. paratuberculosis infected cattle

    DEFF Research Database (Denmark)

    Mikkelsen, Heidi; Aagaard, Claus; Nielsen, Søren Saxmose

    consisting of undefined antigens with possible cross reactions toward other environmental bacteria. The objective of the study was to optimize the IFN-γ test using different types of novel antigens for stimulation. Fourteen novel antigen candidates were selected for testing, including 4 peptides of the ESAT...

  16. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Science.gov (United States)

    2010-04-01

    .... Class II (special controls). Tumor markers must comply with the following special controls: (1) A... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tumor-associated antigen immunological test system... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Tumor Associated Antigen...

  17. Construction, expression, purification and biotin labeling of a single recombinant multi-epitope antigen for double-antigen sandwich ELISA to detect hepatitis C virus antibody.

    Science.gov (United States)

    He, Jing; Xiu, Bingshui; Wang, Guohua; Chen, Kun; Feng, Xiaoyan; Song, Xiaoguo; Zhu, Cuixia; Yang, Xiqin; Bai, Guanzhong; Ling, Shigan; Zhang, Heqiu

    2011-08-01

    Based on B cell epitope predictions, a recombinant antigen with multiple epitopes from four Hepatitis C Virus fragments (C, NS3, NS4 and NS5) were engineered. The recombinant gene was then highly expressed in E. coli. The non-modified and C-terminal-modified recombinant proteins were used for coating and biotin labeling, respectively, to establish the double-antigen sandwich ELISA. Ten positive reference samples confirmed by the CHIRON RIBA HCV 3.0 SIA kit were detected positive, Forty one plasma samples were positive among samples from 441 volunteers, which indicated that the recombinant antigen could readily react well with plasma HCV antibody. As critical reagents of double-antigen sandwich ELISA, the recombinant multi-epitope antigen and the C-terminal-modified and biotin-conjugated antigen show good antigenicity. In this study, we provide a simple approach to produce multiple epitopes within one recombinant protein in order to avoid the costly expression of less-effective pools of multiple proteins, which is the conventional strategy of diagnostic antigen production for HCV antibody detection.

  18. Acute HIV Discovered During Routine HIV Screening With HIV Antigen-Antibody Combination Tests in 9 US Emergency Departments.

    Science.gov (United States)

    White, Douglas A E; Giordano, Thomas P; Pasalar, Siavash; Jacobson, Kathleen R; Glick, Nancy R; Sha, Beverly E; Mammen, Priya E; Hunt, Bijou R; Todorovic, Tamara; Moreno-Walton, Lisa; Adomolga, Vincent; Feaster, Daniel J; Branson, Bernard M

    2018-01-05

    Newer combination HIV antigen-antibody tests allow detection of HIV sooner after infection than previous antibody-only immunoassays because, in addition to HIV-1 and -2 antibodies, they detect the HIV-1 p24 antigen, which appears before antibodies develop. We determine the yield of screening with HIV antigen-antibody tests and clinical presentations for new diagnoses of acute and established HIV infection across US emergency departments (EDs). This was a retrospective study of 9 EDs in 6 cities with HIV screening programs that integrated laboratory-based antigen-antibody tests between November 1, 2012, and December 31, 2015. Unique patients with newly diagnosed HIV infection were identified and classified as having either acute HIV infection or established HIV infection. Acute HIV infection was defined as a repeatedly reactive antigen-antibody test result, a negative HIV-1/HIV-2 antibody differentiation assay, or Western blot result, but detectable HIV ribonucleic acid (RNA); established HIV infection was defined as a repeatedly reactive antigen-antibody test result and a positive HIV-1/HIV-2 antibody differentiation assay or Western blot result. The primary outcomes were the number of new HIV diagnoses and proportion of patients with laboratory-defined acute HIV infection. Secondary outcomes compared reason for visit and the clinical presentation of acute HIV infection. In total, 214,524 patients were screened for HIV and 839 (0.4%) received a new diagnosis, of which 122 (14.5%) were acute HIV infection and 717 (85.5%) were established HIV infection. Compared with patients with established HIV infection, those with acute HIV infection were younger, had higher RNA and CD4 counts, and were more likely to have viral syndrome (41.8% versus 6.5%) or fever (14.3% versus 3.4%) as their reason for visit. Most patients with acute HIV infection displayed symptoms attributable to acute infection (median symptom count 5 [interquartile range 3 to 6]), with fever often

  19. Solid phase radioimmunoassay for detection of malaria antigen. Comparison of monoclonal and polyclonal antibodies

    International Nuclear Information System (INIS)

    Khusmith, S.; Tharavanij, S.; Patarapotikul, J.; Kasemsuth, R.; Bunnag, D.

    1986-01-01

    A solid phase competitive binding radioimmunoassay (RIA) was developed for the detection of Plasmodium falciparum in infected blood. A suspension of NP40 treated red blood cells was mixed with labelled antimalarial IgG, incubated and then added to malarial antigen coated microtitre plate. Antimalarial IgGs were purified either from high titre sera from individuals living in a malaria endemic area in Thailand or from a locally produced monoclonal antibody (MAB) which showed a bright generalized immunofluorescent staining pattern against all blood stages of P. falciparum, including gametocytes. This MAB reacted with 27 of 31 P. falciparum isolates from Thailand. Using dilution of red blood cells from in vitro cultures of P. falciparum, the test was found to detect parasites at levels equivalent to 13 and 2.2 parasites/10 6 red blood cells with labelled polyclonal IgG (PIgG) and labelled monoclonal IgG (MIgG), respectively. No false positive results were obtained among samples from non-malarial subjects. Of the samples that gave negative results upon microscopic examination, 50 and 35% were still positive with RIA using MIgG and PIgG, respectively. There was a correlation between RIA and the number of parasites, especially when MIgG was used. The results indicate that the IgG fraction of sera from individuals with natural acquired immunity to malaria showed a lower degree of sensitivity in parasite detection than the IgG from monoclonal antibody. (author)

  20. The challenge of producing skin test antigens with minimal resources suitable for human application against a neglected tropical disease; leprosy.

    Directory of Open Access Journals (Sweden)

    Becky L Rivoire

    Full Text Available True incidence of leprosy and its impact on transmission will not be understood until a tool is available to measure pre-symptomatic infection. Diagnosis of leprosy disease is currently based on clinical symptoms, which on average take 3-10 years to manifest. The fact that incidence, as defined by new case detection, equates with prevalence, i.e., registered cases, suggests that the cycle of transmission has not been fully intercepted by implementation of multiple drug therapy. This is supported by a high incidence of childhood leprosy. Epidemiological screening for pre-symptomatic leprosy in large endemic populations is required to facilitate targeted chemoprophylactic interventions. Such a test must be sensitive, specific, simple to administer, cost-effective, and easy to interpret. The intradermal skin test method that measures cell-mediated immunity was explored as the best option. Prior knowledge on skin testing of healthy subjects and leprosy patients with whole or partially fractionated Mycobacterium leprae bacilli, such as Lepromin or the Rees' or Convit' antigens, has established an acceptable safety and potency profile of these antigens. These data, along with immunoreactivity data, laid the foundation for two new leprosy skin test antigens, MLSA-LAM (M. leprae soluble antigen devoid of mycobacterial lipoglycans, primarily lipoarabinomannan and MLCwA (M. leprae cell wall antigens. In the absence of commercial interest, the challenge was to develop these antigens under current good manufacturing practices in an acceptable local pilot facility and submit an Investigational New Drug to the Food and Drug Administration to allow a first-in-human phase I clinical trial.

  1. The challenge of producing skin test antigens with minimal resources suitable for human application against a neglected tropical disease; leprosy.

    Science.gov (United States)

    Rivoire, Becky L; TerLouw, Stephen; Groathouse, Nathan A; Brennan, Patrick J

    2014-01-01

    True incidence of leprosy and its impact on transmission will not be understood until a tool is available to measure pre-symptomatic infection. Diagnosis of leprosy disease is currently based on clinical symptoms, which on average take 3-10 years to manifest. The fact that incidence, as defined by new case detection, equates with prevalence, i.e., registered cases, suggests that the cycle of transmission has not been fully intercepted by implementation of multiple drug therapy. This is supported by a high incidence of childhood leprosy. Epidemiological screening for pre-symptomatic leprosy in large endemic populations is required to facilitate targeted chemoprophylactic interventions. Such a test must be sensitive, specific, simple to administer, cost-effective, and easy to interpret. The intradermal skin test method that measures cell-mediated immunity was explored as the best option. Prior knowledge on skin testing of healthy subjects and leprosy patients with whole or partially fractionated Mycobacterium leprae bacilli, such as Lepromin or the Rees' or Convit' antigens, has established an acceptable safety and potency profile of these antigens. These data, along with immunoreactivity data, laid the foundation for two new leprosy skin test antigens, MLSA-LAM (M. leprae soluble antigen devoid of mycobacterial lipoglycans, primarily lipoarabinomannan) and MLCwA (M. leprae cell wall antigens). In the absence of commercial interest, the challenge was to develop these antigens under current good manufacturing practices in an acceptable local pilot facility and submit an Investigational New Drug to the Food and Drug Administration to allow a first-in-human phase I clinical trial.

  2. Relation between laboratory test results and histological hepatitis activity in individuals positive for hepatitis B surface antigen and antibodies to hepatitis B e antigen

    NARCIS (Netherlands)

    ter Borg, F.; ten Kate, F. J.; Cuypers, H. T.; Leentvaar-Kuijpers, A.; Oosting, J.; Wertheim-van Dillen, P. M.; Honkoop, P.; Rasch, M. C.; de Man, R. A.; van Hattum, J.; Chamuleau, R. A.; Reesink, H. W.; Jones, E. A.

    1998-01-01

    BACKGROUND: Hepatitis B surface antigen (HBsAg) and antibodies to hepatitis B e antigen (anti-HBe) commonly coexist, and laboratory tests are often requested to assess histological hepatitis activity. An optimum panel of tests has not been found and the usefulness of hepatitis B virus (HBV) DNA

  3. Performance comparison of new generation HCV core antigen test versus HCV RNA test in management of hepatitis C virus infection.

    Science.gov (United States)

    Çetiner, Salih; Çetin Duran, Alev; Kibar, Filiz; Yaman, Akgün

    2017-06-01

    The study has evaluated the performance of HCV core antigen (Cag) test by comparing HCV RNA PCR assay which is considered the gold standard for management of HCV infection. Totally, 132 samples sent for HCV RNA (real-time PCR) test were included in the study. Anti-HCV antibody test and HCV Cag test were performed by chemiluminescent enzyme immunoassay (CMEI). Anti-HCV test was positive in all samples. HCV RNA was detected in 112/132 (84.8%) samples, and HCV Cag in 105/132 (79.5%). The most common HCV genotype was genotype 1 (86%). Considering the HCV RNA test as gold standard; the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of Cag test were found to be 93.75%, 100%, 100%, 74.07% and 94.69%, respectively, and paired test results were detected as highly concordant. A high level of correlation was seen between HCV RNA and Cag tests, however, the concordance between the two tests appeared to be disrupted at viral loads lower than 10 3 IU/mL. On the contrary, the correlation reached significance for the values higher than 10 3 IU/mL. Viral loads were in the 17-2500IU/mL range for the negative results for Cag test. Pearson's correlation coefficient revealed a considerably high correlation. The concordance between HCV RNA and Cag tests was disrupted under a viral load lower than 10 3 IU/mL. Therefore, it would be appropriate to consider cost effectiveness, advantages and limitations of the HCV RNA and Cag tests during the decision on which method to use for patient management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Detection of B-lymphocytes secreting antibodies to Dermatophagoides antigens

    DEFF Research Database (Denmark)

    Sparholt, S H; Barington, T; Schou, C

    1991-01-01

    Alutard, showed that 1 week after injection, circulating allergen-specific antibody-secreting cells (AbSC) were detected with this assay. The ranges were between 1 and 13 IgM-, 2 and 20 IgG- and 20 and 55 IgA allergen-specific AbSC per 10(6) MNC. It is expected that this assay will help to understand more...

  5. The diagnostic sensitivity of dengue rapid test assays is significantly enhanced by using a combined antigen and antibody testing approach.

    Directory of Open Access Journals (Sweden)

    Scott R Fry

    2011-06-01

    Full Text Available BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1 has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum. AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test. METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples. KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6% and 96% (95% CI: 92.2% to 99.8 respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1% and 96.7% specificity (95% CI: 82.8% to 99.9% compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers. CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.

  6. Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.

    Directory of Open Access Journals (Sweden)

    Subhamoy Pal

    Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.

  7. Comparison of Xpert Flu rapid nucleic acid testing with rapid antigen testing for the diagnosis of influenza A and B.

    Science.gov (United States)

    DiMaio, Michael A; Sahoo, Malaya K; Waggoner, Jesse; Pinsky, Benjamin A

    2012-12-01

    Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Utility of galactomannan antigen detection in bronchoalveolar lavage fluid in immunocompromised patients.

    Science.gov (United States)

    Brownback, Kyle R; Pitts, Lucas R; Simpson, Steven Q

    2013-09-01

    Diagnosis of invasive pulmonary aspergillosis (IPA) is a challenging process in immunocompromised patients. Galactomannan (GM) antigen detection in bronchoalveolar lavage (BAL) fluid is a method to detect IPA with improved sensitivity over conventional studies. We sought to determine the diagnostic yield of BAL GM assay in a diverse population of immunocompromised patients. A retrospective review of 150 fiberoptic bronchoscopy (FOB) with BAL for newly diagnosed pulmonary infiltrate in immunocompromised patients was performed. Patient information, procedural details and laboratory studies were collected. BAL and serum samples were evaluated for GM using enzyme-linked immunoassay. Of 150 separate FOB with BAL, BAL GM was obtained in 143 samples. There were 31 positive BAL GM assays. In those 31 positive tests, 13 were confirmed as IPA, giving a positive predictive value of 41.9%. There was one false negative BAL GM. Of the 18 false positive BAL GM, 4 were receiving piperacillin-tazobactam and 11 were receiving an alternative beta-lactam antibiotic. BAL GM assay shows excellent sensitivity for diagnosing IPA. There was a significant number of false positive BAL GM assays and several of those patients were receiving beta-lactam antibiotics at the time of bronchoscopy. © 2013 Blackwell Verlag GmbH.

  9. Prostate Cancer Detection and Prognosis: From Prostate Specific Antigen (PSA) to Exosomal Biomarkers.

    Science.gov (United States)

    Filella, Xavier; Foj, Laura

    2016-10-26

    Prostate specific antigen (PSA) remains the most used biomarker in the management of early prostate cancer (PCa), in spite of the problems related to false positive results and overdiagnosis. New biomarkers have been proposed in recent years with the aim of increasing specificity and distinguishing aggressive from non-aggressive PCa. The emerging role of the prostate health index and the 4Kscore is reviewed in this article. Both are blood-based tests related to the aggressiveness of the tumor, which provide the risk of suffering PCa and avoiding negative biopsies. Furthermore, the use of urine has emerged as a non-invasive way to identify new biomarkers in recent years, including the PCA3 and TMPRSS2:ERG fusion gene. Available results about the PCA3 score showed its usefulness to decide the repetition of biopsy in patients with a previous negative result, although its relationship with the aggressiveness of the tumor is controversial. More recently, aberrant microRNA expression in PCa has been reported by different authors. Preliminary results suggest the utility of circulating and urinary microRNAs in the detection and prognosis of PCa. Although several of these new biomarkers have been recommended by different guidelines, large prospective and comparative studies are necessary to establish their value in PCa detection and prognosis.

  10. Evaluation of five hepatitis delta virus marker assays for detection of antigen and antibody.

    OpenAIRE

    Bezeaud, A; Rosenswajg, M; Guillin, M C

    1989-01-01

    Five commercially available assays for hepatitis delta (HD) virus markers were compared for sensitivity, specificity, and reproducibility: three assays for antibody (anti-HD), provided by Diagnostics Pasteur, Organon Teknika, and Abbott Laboratories, and two assays for antigen (HD Ag), from Pasteur and Organon Teknika. The assay from Organon Teknika is the less sensitive assay for anti-HD detection. Although the sensitivities of the Pasteur and Abbott assays for anti-HD detection are similar,...

  11. Use of Digital Rectal Examination as an Adjunct to Prostate Specific Antigen in the Detection of Clinically Significant Prostate Cancer.

    Science.gov (United States)

    Halpern, Joshua A; Oromendia, Clara; Shoag, Jonathan E; Mittal, Sameer; Cosiano, Michael F; Ballman, Karla V; Vickers, Andrew J; Hu, Jim C

    2018-04-01

    Guidelines from the NCCN ® (National Comprehensive Cancer Network®) advocate digital rectal examination screening only in men with elevated prostate specific antigen. We investigated the effect of prostate specific antigen on the association of digital rectal examination and clinically significant prostate cancer in a large American cohort. We evaluated the records of the 35,350 men who underwent digital rectal examination in the screening arm of the Prostate, Lung, Colorectal and Ovarian Cancer Screening trial for the development of clinically significant prostate cancer (Gleason 7 or greater). Followup was 343,273 person-years. The primary outcome was the rate of clinically significant prostate cancer among men with vs without suspicious digital rectal examination. We performed competing risks regression to evaluate the interaction between time varying suspicious digital rectal examination and prostate specific antigen. A total of 1,713 clinically significant prostate cancers were detected with a 10-year cumulative incidence of 5.9% (95% CI 5.6-6.2). Higher risk was seen for suspicious vs nonsuspicious digital rectal examination. Increases in absolute risk were small and clinically irrelevant for normal (less than 2 ng/ml) prostate specific antigen (1.5% vs 0.7% risk of clinically significant prostate cancer at 10 years), clinically relevant for elevated (3 ng/ml or greater) prostate specific antigen (23.0% vs 13.7%) and modestly clinically relevant for equivocal (2 to 3 ng/ml) prostate specific antigen (6.5% vs 3.5%). Digital rectal examination demonstrated prognostic usefulness when prostate specific antigen was greater than 3 ng/ml, limited usefulness for less than 2 ng/ml and marginal usefulness for 2 to 3 ng/ml. These findings support the restriction of digital rectal examination to men with higher prostate specific antigen as a reflex test to improve specificity. It should not be used as a primary screening modality to improve sensitivity. Copyright

  12. The end of the road for prostate specific antigen testing? | Nna ...

    African Journals Online (AJOL)

    Many candidate biomarkers for diagnosis of prostate cancer have been investigated, but prostate‑specific antigen (PSA) testing remains the frontline test for both mass screening and individual clinical testing. Although the PSA test is cost‑effective, analytically reliable, and flexibly high throughput, it has a very weak ...

  13. Comparison of excretory-secretory antigen and positive faecal supernatant antigen in the detection of Echinococcus granulosus infection in dogs by CIEP

    Directory of Open Access Journals (Sweden)

    P. R. Prathiush

    Full Text Available Coproantigen detection of Echinococcosis in dogs by counter immunoelectrophoresis was standardized. Adult Echinococcus granulosus worms were obtained from intestine of a necropsied positive dog. Excretory-secretory antigen was prepared by culturing adult worms in Medium 199 (pH 7.4. Faeces of positive dog were collected and fecal supernatant was prepared and used for coproantigen detection. CIEP was carried out using tris-borate buffer (pH 8.0 at a constant current of 8mA/slide for 60 minutes. CIEP detected infection with both the antigens. [Vet World 2009; 2(11.000: 421-422

  14. Follow-up of neurocysticercosis patients after treatment using an antigen detection ELISA

    Directory of Open Access Journals (Sweden)

    Nguekam

    2003-03-01

    Full Text Available Seven patients with active neurocysticercosis (NCC received an eight days treatment with albendazole and were followed up using computed tomography (CT-scan and a monoclonal antibody based ELISA for the detection of circulating antigen (Ag-ELISA. Only three patients were cured as was shown by CT-scan and by the disappearance of circulating antigens one month after treatment. After a second course of albendazole therapy, two other patients became seronegative. CT-scan showed the disappearance of viable cysts in all persons who became seronegative whereas patients who were not cured remained seropositive. These preliminary results show that this Ag-ELISA is a promising technique for monitoring the success of treatment of NCC patients because of the excellent correlation between the presence of circulating antigens and of viable brain cysts.

  15. Making antigen of trypanosoma evansi and its examination by catt (card agglutination test) method

    International Nuclear Information System (INIS)

    Arifin, M; Irtisam; Estikoma Dyah; Yulia Ernawati; Boky, J.T

    1998-01-01

    An experiment was carried out for making antigen (Ag) of T. evansi by using experimental animals rats and guinea pigs for for developing parasites, and in cattle for making immune serum and normal serum. The parasites were irradiated by gamma rays ( 60 Co) at a dose of 300 Gy. The determination of antigen was done by using Card Agglutination Test (CATT) to the field samples serum of cattle. The results obtained showed that antigen was good enough potently and stable at minus 70 0 C storage during five months. (author)

  16. The use of antigen-detection ELISA for the diagnosis of bovine trypanosomosis in Cote d'Ivoire

    International Nuclear Information System (INIS)

    Kone, P.; Komoin-Oka, C.; N'Depo, A.

    1997-01-01

    An Antigen ELISA (Ag-ELISA) detecting circulating antigens of trypanosomes was evaluated in the central region of Cote d'Ivoire for the serodiagnosis of cattle trypanosomosis. Of 1423 sera examined, only 43 were positive in the MHCT/BCT, 105 (7%) were detected using stained blood smears, and 74 (5%) were found positive using the Ag-ELISA. The predominant trypanosome species was T. brucei, being present in 84% of the positive samples as detected by the BCT, in 96% using stained bloodsmears, and in 72% by Ag-ELISA. T.vivax was detected less frequently. The serological (ELISA) test did not detect all positive animals as found by the haematological techniques. However, the two techniques should be used in a complementary way to improve the diagnosis of the disease. The results confirm that the prevalence of trypanosomes in cattle is low in the study area. The low prevalence can be due to prophylaxis and therapy of livestock in combination with successful tsetse trapping. (author). 4 refs, 2 figs, 4 tabs

  17. The use of antigen-detection ELISA for the diagnosis of bovine trypanosomosis in Cote d`Ivoire

    Energy Technology Data Exchange (ETDEWEB)

    Kone, P [Laboratoire Regional de Pathologie Animale de Bouake (LANADA), Bouake (Cote d` Ivoire); Komoin-Oka, C; N` Depo, A [Laboratoire Central de Pathologie Animale de Bingerville (LANADA), Bingerville (Cote d` Ivoire)

    1997-02-01

    An Antigen ELISA (Ag-ELISA) detecting circulating antigens of trypanosomes was evaluated in the central region of Cote d`Ivoire for the serodiagnosis of cattle trypanosomosis. Of 1423 sera examined, only 43 were positive in the MHCT/BCT, 105 (7%) were detected using stained blood smears, and 74 (5%) were found positive using the Ag-ELISA. The predominant trypanosome species was T. brucei, being present in 84% of the positive samples as detected by the BCT, in 96% using stained bloodsmears, and in 72% by Ag-ELISA. T.vivax was detected less frequently. The serological (ELISA) test did not detect all positive animals as found by the haematological techniques. However, the two techniques should be used in a complementary way to improve the diagnosis of the disease. The results confirm that the prevalence of trypanosomes in cattle is low in the study area. The low prevalence can be due to prophylaxis and therapy of livestock in combination with successful tsetse trapping. (author). 4 refs, 2 figs, 4 tabs.

  18. Heat treatment and false-positive heartworm antigen testing in ex vivo parasites and dogs naturally infected by Dirofilaria repens and Angiostrongylus vasorum

    Directory of Open Access Journals (Sweden)

    Luigi Venco

    2017-11-01

    Full Text Available Abstract Background Heartworm antigen testing is considered sensitive and specific. Currently available tests are reported as detecting a glycoprotein found predominantly in the reproductive tract of the female worm and can reach specificity close to 100%. Main concerns regard sensitivity in the case of light infections, the presence of immature females or cases of all-male infections. Research and development have been aimed at increasing sensitivity. Recently, heat treatment of serum prior to antigen testing has been shown to result in an increase in positive antigen test results, presumably due to disruption of natural antigen–antibody complexes. Cross-reactions in dogs with both natural and experimental infections with Angiostrongylus vasorum and Spirocerca lupi have been reported, but cross-reactions with other helminths have not been extensively studied. In order to evaluate potential cross-reactivity with other canine and feline parasites, two studies were performed. Study 1: Live adults of Dirofilaria immitis, Dirofilaria repens, Toxocara canis, Toxocara cati, Dipylidium caninum, Taenia taeniaeformis and Mesocestoides spp. larvae were washed and incubated in tubes with saline solution. All worms were alive at the time of removal from the saline. Saline solutions containing excretory/secretory antigens were then tested for heartworm with six different, commercially available antigen tests. All results were evaluated blind by three of the authors. Study 2: Sera from dogs with natural infections by A. vasorum or D. repens, living in areas free of heartworm disease, were tested with the same tests before and after heat treatment (103 °C for 10 min. Results Results suggest that antigens detected by currently available tests are not specific for D. immitis. They may give positive results through detection of different parasites’ antigens that are normally not released into the bloodstream or released in a low amount and/or bound to

  19. 9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3

    Science.gov (United States)

    2010-01-01

    ...-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure described is a modification of the method reported by Schaffer, MacDonald, Hall, and Bunyea, Jour. Amer. Vet...

  20. [Evaluation of an ELISA test with Fasciola hepatica metabolic antigen for diagnosis of human fascioliasis in Cajamarca, Peru].

    Science.gov (United States)

    Cornejo, Hernán; Oblitas, Fátima; Cruzado, Sandro; Quispe, William

    2010-01-01

    Metabolic (excretion/secretion) antigen was obtained from sheep infected with Fasciola hepatica, with a 1005 μg/μL of protein concentration, composed principally by proteins of molecular weight between 1.2 and 170 KDa. Bands of 170, 150, 31, 24, 18-14 and 10 kDa were detected. With this antigen an ELISA test was developed and the cut off was determined in 0.140. We evaluated 33 serums of patient with fascioliasis confirmed by visualization of eggs in feces, 177 serums of persons without fascioliasis from endemic rural areas of Cajamarca and 88 serums of patients with others parasitic and bacterial infections. We found a 97.0% of sensitivity, 96.6 specificity, 78.1% predictive positive value, 99.6 % predictive negative value. In 9/88 serums was found cross reactions. We recommended the implementation and use of this test for the fascioliasis diagnosis.

  1. Sensitive and specific detection of Crimean-Congo Hemorrhagic Fever Virus (CCHFV)—Specific IgM and IgG antibodies in human sera using recombinant CCHFV nucleoprotein as antigen in μ-capture and IgG immune complex (IC) ELISA tests

    Science.gov (United States)

    Emmerich, Petra; Mika, Angela; von Possel, Ronald; Rackow, Anne; Liu, Yang; Schmitz, Herbert; Sherifi, Kurtesh; Halili, Barie; Jakupi, Xhevat; Berisha, Lindita; Ahmeti, Salih

    2018-01-01

    As the most widespread tick-borne arbovirus causing infections in numerous countries in Asia, Africa and Europe, Crimean-Congo Hemorrhagic Fever Virus (CCHFV, family Nairoviridae) was included in the WHO priority list of emerging pathogens needing urgent Research & Development attention. To ensure preparedness for potential future outbreak scenarios, reliable diagnostic tools for identification of acute cases as well as for performance of seroprevalence studies are necessary. Here, the CCHFV ortholog of the major bunyavirus antigen, the nucleoprotein (NP), was recombinantly expressed in E.coli, purified and directly labeled with horseradish peroxidase (HRP). Employing this antigen, two serological tests, a μ-capture ELISA for the detection of CCHFV-specific IgM antibodies (BLACKBOX CCHFV IgM) and an IgG immune complex (IC) ELISA for the detection of CCHFV-specific IgG antibodies (BLACKBOX CCHFV IgG), were developed. Test performance was evaluated and compared with both in-house gold standard testing by IgM/IgG indirect immunofluorescence (IIF) and commercially available ELISA tests (VectoCrimean-CHF-IgM/IgG, Vector-Best, Russia) using a serum panel comprising paired samples collected in Kosovo during the years 2013–2016 from 15 patients with an acute, RT-PCR-confirmed CCHFV infection, and 12 follow-up sera of the same patients collected approximately one year after having overcome the infection. Reliably detecting IgM antibodies in all acute phase sera collected later than day 4 after onset of symptoms, both IgM ELISAs displayed excellent diagnostic and analytical sensitivity (100%, 95% confidence interval (CI): 85.2%–100.0%). While both IgG ELISAs readily detected the high IgG titers present in convalescent patients approximately one year after having overcome the infection (sensitivity 100%, 95% CI: 73.5%–100.0%), the newly developed BLACKBOX CCHFV IgG ELISA was superior to the commercial IgG ELISA in detecting the rising IgG titers during the acute phase

  2. A solid phase radio immunoassay on hydrophobic membrane filters: detection of antibodies to gonocal surface antigens

    International Nuclear Information System (INIS)

    Lambden, P.R.; Watt, P.J.

    1978-01-01

    A solid phase radioimmunoassay (SPRIA) has been developed for detection of IgG antibodies to gonococcal outer membrane components. Gonococcal antigens was immobilised on a solid support by covalent coupling to CNBr-activated Sepharose in the presence of the detergent Triton X-100. Binding of specific antibody to the Sepharose-antigen complex was detected using radiolabelled Protein A as the antiglobulin. Protein A was labelled by radioacetylation with tritiated acetic anhydride, yielding a product of high specific activity and high stability. No detectable loss of activity was observed over a ten month period. The entire assay was performed on Mitex teflon hydrophobic membrane filters which held the Sepharose beads and aqueous supernatant as a discrete drop of liquid. The supernatants and incubation were easily and rapidly removed from the beads by suction on a specially-designed manifold system. This procedure removed the need for repeated and time-consuming centrifugations. Titres were obtained graphically from double log plots of cpm bound versus antiserum dilution by extrapolation of the straight line to a point corresponding to twice the control level of radioactivity binding. The assay proved to be a very reliable and simple procedure for the detection of IgG antibodies to gonococcal surface antigens. (Auth.)

  3. Application and Comparative Evaluation of Fluorescent Antibody, Immunohistochemistry and Reverse Transcription Polymerase Chain Reaction Tests for the Detection of Rabies Virus Antigen or Nucleic Acid in Brain Samples of Animals Suspected of Rabies in India

    Directory of Open Access Journals (Sweden)

    K. Nithin Prabhu

    2018-02-01

    Full Text Available Accurate and early diagnosis of animal rabies is critical for undertaking public health measures. Whereas the direct fluorescent antibody (DFA technique is the recommended test, the more convenient, direct rapid immunochemistry test (dRIT, as well as the more sensitive, reverse transcription polymerase chain reaction (RT-PCR, have recently been employed for the laboratory diagnosis of rabies. We compared the three methods on brain samples from domestic (dog, cat, cattle, buffalo, horse, pig and goat and wild (leopard, wolf and jackal animals from various parts of India. Of the 257 samples tested, 167 were positive by all the three tests; in addition, 35 of the 36 decomposed samples were positive by RT-PCR. This is the first study in which such large number of animal samples have been subjected to the three tests simultaneously. The results confirm 100% corroboration between DFA and dRIT, buttress the applicability of dRIT in the simple and rapid diagnosis of rabies in animals, and reaffirm the suitability of RT-PCR for samples unfit for testing either by DFA or dRIT.

  4. Application and Comparative Evaluation of Fluorescent Antibody, Immunohistochemistry and Reverse Transcription Polymerase Chain Reaction Tests for the Detection of Rabies Virus Antigen or Nucleic Acid in Brain Samples of Animals Suspected of Rabies in India.

    Science.gov (United States)

    Prabhu, K Nithin; Isloor, Shrikrishna; Veeresh, B Hanchinal; Rathnamma, Doddamane; Sharada, R; Das, Lekshmi J; Satyanarayana, M L; Hegde, Nagendra R; Rahman, Sira Abdul

    2018-02-28

    Accurate and early diagnosis of animal rabies is critical for undertaking public health measures. Whereas the direct fluorescent antibody (DFA) technique is the recommended test, the more convenient, direct rapid immunochemistry test (dRIT), as well as the more sensitive, reverse transcription polymerase chain reaction (RT-PCR), have recently been employed for the laboratory diagnosis of rabies. We compared the three methods on brain samples from domestic (dog, cat, cattle, buffalo, horse, pig and goat) and wild (leopard, wolf and jackal) animals from various parts of India. Of the 257 samples tested, 167 were positive by all the three tests; in addition, 35 of the 36 decomposed samples were positive by RT-PCR. This is the first study in which such large number of animal samples have been subjected to the three tests simultaneously. The results confirm 100% corroboration between DFA and dRIT, buttress the applicability of dRIT in the simple and rapid diagnosis of rabies in animals, and reaffirm the suitability of RT-PCR for samples unfit for testing either by DFA or dRIT.

  5. Comparison of three techniques for production goat lentivirus antigen used in the agar gel immunodifusion test

    Directory of Open Access Journals (Sweden)

    Raymundo Rizaldo Pinheiro

    2005-12-01

    Full Text Available The Caprine Arthritis Encephalitis (CAE is a disease who cause considerable economic losses, including loss in the milk production and reduction of the useful life of the animal. In the diagnosis of this disease the agar gel immunodifusion test (AGID is used worldwide as the selection test. The objective of thid work was to test three different concentrations of bovine fetal serum (BFS in the production of the antigen (Ag for the diagnosis of the CAE virus (CAEV, to verify amongst the three methods the most efficient concentration and which the antigen concentration of the antigen produced is appropriate for the test. The method of the AMICON and the concentration of the Ag for dialysis was indicated, however the system AMICON, despite the implantation costs, promoted minor loss of antigen, little time expense in the processing and greater simplicity. With relation to the amount of BFS placed after the viral inoculation it was verified that 5% of BFS the amount that presented better resulted. The antigen concentration 100 times was more indicated, therefore it allowed the diagnosis of the CAEV for two proteins (gp 135 and p28. The concentration of the Ag for precipitation/ultracentrifugation, used for imunoenzimatic tests, did not present resulted satisfactory used in the AGID.

  6. Evaluation and optimization of the Circulating Cathodic Antigen (POC-CCA) cassette test for detecting Schistosoma mansoni infection by using image analysis in school children in Mwanza Region, Tanzania

    DEFF Research Database (Denmark)

    Partal, Miriam Casacuberta; Kinunghi, Safari; Vennervald, Birgitte J

    2016-01-01

    of Lake Victoria in Mwanza Region, Tanzania, and to optimize the reading of the POC-CCA test lines by using a computer software image analysis. Initially, a pilot study in 106 school children indicated that time of urine collection did not have an impact on CCA results as 84.9% (90) had identical scores...... POC-CCAs were compared to six Kato-Katz smears (75.0% vs. 42.6%; p reading of the POC-CCA, a Software...... tool (Image Studio Lite®) was used to read and quantify the colour (expressed as pixels) of the test line on all positive tests, showing a positive correlation between number of pixels and the visually scored intensities and between number of pixels and egg counts. In conclusion, the POC-CCA assay...

  7. Analytical Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection

    Science.gov (United States)

    Cross, Robert W.; Boisen, Matthew L.; Millett, Molly M.; Nelson, Diana S.; Oottamasathien, Darin; Hartnett, Jessica N.; Jones, Abigal B.; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shunichiro; Brown, Bethany L.; Pham, Ha; Rowland, Megan M.; Agans, Krystle N.; Geisbert, Joan B.; Heinrich, Megan L.; Kulakosky, Peter C.; Shaffer, Jeffrey G.; Schieffelin, John S.; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M.; Wilson, Russell B.; Saphire, Erica Ollmann; Pitts, Kelly R.; Khan, Sheik Humarr; Grant, Donald S.; Geisbert, Thomas W.; Branco, Luis M.; Garry, Robert F.

    2016-01-01

    Background. Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013–2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases. Methods. Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance. Results. The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription–polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 105–9.0 × 108 genomes/mL. Conclusions. The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. PMID:27587634

  8. Analytical Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection.

    Science.gov (United States)

    Cross, Robert W; Boisen, Matthew L; Millett, Molly M; Nelson, Diana S; Oottamasathien, Darin; Hartnett, Jessica N; Jones, Abigal B; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A; Fusco, Marnie L; Abelson, Dafna M; Oda, Shunichiro; Brown, Bethany L; Pham, Ha; Rowland, Megan M; Agans, Krystle N; Geisbert, Joan B; Heinrich, Megan L; Kulakosky, Peter C; Shaffer, Jeffrey G; Schieffelin, John S; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M; Wilson, Russell B; Saphire, Erica Ollmann; Pitts, Kelly R; Khan, Sheik Humarr; Grant, Donald S; Geisbert, Thomas W; Branco, Luis M; Garry, Robert F

    2016-10-15

     Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013-2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases.  Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance.  The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription-polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 10 5 -9.0 × 10 8 genomes/mL.  The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  9. Design of indirect solid-phase immunosorbent methods for detecting arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A

    1984-05-01

    Specifications have been elaborated for formulating indirect solid-phase enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (SPRIA) methods that employ anti-human and anti-mice G class immunoglobulin (IgG), conjugated with horseradish peroxidase and /sup 125/I for detecting the arenaviruses Junin, Machupo, Tacaribe, Amalpari, Tamiami, Lassa, and LCM (lymphocytic choriomeningitis). These methods make it possible to identify with a high degree of sensitivity arenavirus antigens and antibodies in various kinds of material.

  10. Use of an immunodominant p17 antigenic fraction of Neospora caninum in detection of antibody response in cattle

    Directory of Open Access Journals (Sweden)

    Gema Álvarez García

    2006-08-01

    Full Text Available A Neospora caninum 17 kDa protein fraction (p17 has been described as an immunodominant antigen (IDA under reducing and non-reducing conditions. The aim of the present study was to investigate the diagnostic utility of p17 in cattle. In order to achieve this, p17 was purified by electroelution from whole N. caninum tachyzoite soluble extract and a p17-based Western blot (WB-p17 was developed. The p17 recognition was measured by densitometry and expressed as OD values to check the validity of the WB-p17. A total of 131 sera including sequential samples from naturally- and experimentally-infected calves and breeding cattle were analysed by WB-p17 and compared with IFAT using whole formalin-fixed tachyzoites as a reference test. The results obtained highlight the feasibility of using the N. caninum p17 in a diagnostic test in cattle. Firstly, the assay based on the p-17 antigen discriminated between known positive and negative sera from different cattle populations, breeding cattle and calves. Secondly, the p17 antigen detected fluctuations in the antibody levels and seroconversion in naturally- and experimentally-infected cattle. Significant differences in p-17 antigen recognition were observed between naturally infected aborting and non-aborting cattle, as well as significant antibody fluctuations over time in experimentally infected cattle, which varied between groups. Furthermore, the results obtained with WB-p17 are in accordance with the results obtained with the IFAT, as high agreement values were obtained when all bovine subpopulations were included (kappa = 0.86.

  11. A novel one-step Helicobacter pylori saliva antigen test

    Directory of Open Access Journals (Sweden)

    Bi-Ling Yang

    2015-02-01

    Conclusion: The one-step HPS test exhibited a high sensitivity and low specificity compared with the other tests, indicating that it is not sufficiently accurate for use in a clinical setting for diagnosing H. pylori infection. However, the test is simple to use (requiring only a saliva sample, inexpensive, and noninvasive in its application, and thus appealing for use in population-based prevalence surveys of the epidemiology of H. pylori infection.

  12. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    Science.gov (United States)

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of the antigen assay was confirmed by using guinea pig immunoglobulins from preimmunization sera. The sensitivity of the antigen assay was found to be at least 10 ng of antigen protein per ml. The suitability of the method for detecting antigens of T. gondii in different specimens was studied by experimental toxoplasma infection in mice. Antigenic components of T. gondii could be detected in different tissue specimens from infected animals from the first day after infection onwards. Toxoplasma antigen in serum and urine samples from infected mice reached detectable levels on day 2 after infection followed by a linear increase in antigen concentration in succeeding samples. This method might offer a valuable aid for a rapid etiological diagnosis also in human cases of acute toxoplasmosis. PMID:6345574

  13. ELISA for detection of variant rabbit haemorrhagic disease virus RHDV2 antigen in liver extracts.

    Science.gov (United States)

    Dalton, K P; Podadera, A; Granda, V; Nicieza, I; Del Llano, D; González, R; de Los Toyos, J R; García Ocaña, M; Vázquez, F; Martín Alonso, J M; Prieto, J M; Parra, F; Casais, R

    2018-01-01

    The emergence and rapid spread of variant of the rabbit hemorrhagic disease virus (RHDV2) require new diagnostic tools to ensure that efficient control measures are adopted. In the present study, a specific sandwich enzyme-linked immunosorbent assay (ELISA) for detection of RHDV2 antigens in rabbit liver homogenates, based on the use of an RHDV2-specific monoclonal antibody (Mab) 2D9 for antigen capture and an anti-RHDV2 goat polyclonal antibody (Pab), was developed. This ELISA was able to successfully detect RHDV2 and RHDV2 recombinant virions with high sensitivity (100%) and specificity (97.22%). No cross-reactions were detected with RHDV G1 viruses while low cross-reactivity was detected with one of the RHDVa samples analyzed. The ELISA afforded good repeatability and had high analytical sensitivity as it was able to detect a dilution 1:163,640 (6.10ng/mL) of purified RHDV-N11 VLPs, which contained approximately 3.4×10 8 molecules/mL particles. The reliable discrimination between closely related viruses is crucial to understand the epidemiology and the interaction of co-existing pathogens. In the work described here we design and validate an ELISA for laboratory based, specific, sensitive and reliable detection of RHDVb/RHDV2. This ELISA is a valuable, specific virological tool for monitoring virus circulation, which will permit a better control of this disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Detection of Puumala hantavirus antigen in human intestine during acute hantavirus infection.

    Directory of Open Access Journals (Sweden)

    Joerg Latus

    Full Text Available BACKGROUND: Puumala virus (PUUV is the most important hantavirus species in Central Europe. Nephropathia epidemica (NE, caused by PUUV, is characterized by acute renal injury (AKI with thrombocytopenia and frequently gastrointestinal symptoms. METHODS: 456 patients with serologically and clinically confirmed NE were investigated at time of follow-up in a single clinic. The course of the NE was investigated using medical reports. We identified patients who had endoscopy with intestinal biopsy during acute phase of NE. Histopathological, immunohistochemical and molecular analyses of the biopsies were performed. RESULTS: Thirteen patients underwent colonoscopy or gastroscopy for abdominal pain, diarrhea, nausea and vomiting during acute phase of NE. Immunohistochemistry (IHC revealed PUUV nucleocapsid antigen in 11 biopsies from 8 patients; 14 biopsies from 5 patients were negative for PUUV nucleocapsid antigen. IHC localized PUUV nucleocapsid antigen in endothelial cells of capillaries or larger vessels in the lamina propria. Rate of AKI was not higher and severity of AKI was not different in the PUUV-positive compared to the PUUV-negative group. All IHC positive biopsies were positive for PUUV RNA using RT-PCR. Phylogenetic reconstruction revealed clustering of all PUUV strains from this study with viruses previously detected from the South-West of Germany. Long-term outcome was favorable in both groups. CONCLUSIONS: In patients with NE, PUUV nucleocapsid antigen and PUUV RNA was detected frequently in the intestine. This finding could explain frequent GI-symptoms in NE patients, thus demonstration of a more generalized PUUV infection. The RT-PCR was an effective and sensitive method to detect PUUV RNA in FFPE tissues. Therefore, it can be used as a diagnostic and phylogenetic approach also for archival materials. AKI was not more often present in patients with PUUV-positive IHC. This last finding should be investigated in larger numbers of

  15. Radioimmunological test for the cancero-embryonal antigen in evaluation of stomach neoplasm treatment efficiency

    International Nuclear Information System (INIS)

    Klimenkov, A.A.; Tkacheva, G.A.; Gladikov, Yu.V.; Blokhina, N.G.; Ozherel'ev, A.V.

    1979-01-01

    The results of a dynamic determination of the level of the cancero-embryonic antigen are analysed in 30 patients with stomach neoplasm of the 1-3 stages subjected to a radical operation and 22 patients with stage 4 given polychemotherapy. It is shown that information on the nature of the change in the level of the cancero-embryonal antigen in the blood serves as an important criterion for evaluation of the completeness of the tumour mass removal, detection of the disease relapse and comparison of the efficiency of various combinations of antitumor drugs

  16. Impedance-Based Miniaturized Biosensor for Ultrasensitive and Fast Prostate-Specific Antigen Detection

    Directory of Open Access Journals (Sweden)

    Ganna Chornokur

    2011-01-01

    Full Text Available This paper reports the successful fabrication of an impedance-based miniaturized biosensor and its application for ultrasensitive Prostate-Specific Antigen (PSA detection in standard and real human plasma solution, spiked with different PSA concentrations. The sensor was fabricated using photolithographic techniques, while monoclonal antibodies specific to human PSA were used as primary capture antibodies. Electrochemical impedance spectroscopy (EIS was employed as a detection technique. The sensor exhibited a detection limit of 1 pg/ml for PSA with minimal nonspecific binding (NSB. This detection limit is an order of magnitude lower than commercial PSA ELISA assays available on the market. The sensor can be easily modified into an array for the detection of other biomolecules of interest, enabling accurate, ultrasensitive, and inexpensive point-of-care sensing technologies.

  17. A simple assay for the detection of antibodies to endocrine islet cell surface antigens

    International Nuclear Information System (INIS)

    Contreas, G.; Madsen, O.D.; Vissing, H.; Lernmark, Aa.

    1986-01-01

    A simple and sensitive immunoradiometric assay for the detection of islet cell surface antibodies (CIRMA) has been developed. Live, transformed islet cells derived from a liver metastasis of a transplantable islet cell tumor were grown in removable microtiter wells and incubated with antibody. Cell-bound antibodies were quantitated using 125 I-labelled second antibodies. The assay was used to detect islet cell antibodies present in sera from non-diabetic and diabetic BB rats and proved to be particularly effective for screening hybridoma supernatants in order to identify monoclonal antibodies recognizing islet cell surface antigens. (Auth.)

  18. Dot-ELISA for the detection of anti-Cysticercus cellulosae antibodies in cerebrospinal fluid using a new solid phase (resin-treated polyester fabric and Cysticercus longicollis antigens Teste dot-ELISA para detecção de anticorpos anti-Cysticercus cellulosae em líquido cefalorraquiano utilizando um novo suporte (tecido de poliéster-resina e antígenos de Cysticercus longicollis

    Directory of Open Access Journals (Sweden)

    Adelaide José Vaz

    1996-12-01

    Full Text Available A dot-ELISA was developed for the detection of antibodies in CSF in the immunologic diagnosis of human neurocysticercosis, using antigen extracts of the membrane and scolex of Cysticercus cellulosae (M+S-Cc and, alternately, membrane (M and vesicular fluid (VF of Cysticercus longicollis (Cl covalently bound to a new solid phase consisting of polyester fabric treated with N-methylol-acrylamide resin (dot-RT. The test was performed at room temperature, with reduced incubation times and with no need for special care in the manipulation of the support. The sensitivity rates obtained were 95.1% for antigen Cc and 97.6% for antigen Cl. Specificity was 90.6% when Cc was used, and 96.9% and 100% when M-Cl and VF-Cl were used, respectively. No significant differences in titer were observed between tests carried out with homologous and heterologous antigens. The low cost and easy execution of the dot-RT test using antigen extracts of Cysticercus longicollis indicate the test for use in the immunodiagnosis of human neurocysticercosis.Foi desenvolvido o teste dot-ELISA para detecção de anticorpos em líquido cefalorraquiano (LCR no diagnóstico imunológico da neurocisticercose humana, utilizando antígenos de membrana e escólex de Cysticercus cellulosae (M+E-Cc e, alternativamente, membrana (M e líquido vesicular (LV de Cysticercus longicollis (Cl covalentemente ligados a um novo suporte constituído de tecido de poliéster-resina de N-metilol-acrilamida (dot-TR. O teste foi realizado à temperatura ambiente, com tempos de incubação reduzidos e sem necessidade de cuidados na manipulação do suporte. A sensibilidade obtida foi de 95,1% para o antígeno Cc e 97,6% para o Cl. A especificidade foi de 90,6% quando o antígeno Cc foi usado, e 96,9% e 100% para M-Cl e LV-Cl, respectivamente. Não foi observada diferença significativa entre os antígenos homólogo e heterólogo. O baixo custo e a fácil execução do teste dot-TR empregando extratos antig

  19. Positive hepatitis B surface antigen tests due to recent vaccination: a persistent problem

    Directory of Open Access Journals (Sweden)

    Rysgaard Carolyn D

    2012-09-01

    Full Text Available Abstract Background Hepatitis B virus (HBV is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients. However, the time course and duration of this effect is unclear. The objective of this retrospective study was to clarify the frequency and duration of transient HBsAg positivity following vaccination against HBV. Methods The electronic medical record at an academic tertiary care medical center was searched to identify all orders for HBsAg within a 17 month time period. Detailed chart review was performed to identify all patients who were administered HBV vaccine within 180 days prior to HBsAg testing and also to ascertain likely cause of weakly positive (grayzone results. Results During the 17 month study period, 11,719 HBsAg tests were ordered on 9,930 patients. There were 34 tests performed on 34 patients who received HBV vaccine 14 days or less prior to HBsAg testing. Of these 34 patients, 11 had grayzone results for HBsAg that could be attributed to recent vaccination. Ten of the 11 patients were renal dialysis patients who were receiving HBsAg testing as part of routine and ongoing monitoring. Beyond 14 days, there were no reactive or grayzone HBsAg tests that could be attributed to recent HBV vaccination. HBsAg results reached a peak COI two to three days following vaccination before decaying. Further analysis of all the grayzone results within the 17 month study period (43 results out of 11,719 tests revealed that only 4 of 43 were the result of true HBV infection as verified by confirmatory testing. Conclusions Our study confirms that transient HBsAg positivity can occur in patients following HBV vaccination. The results suggest this positivity is unlikely to persist beyond 14 days

  20. DN detection during SLSF tests

    International Nuclear Information System (INIS)

    Braid, T.H.; Harper, H.A.; Wilson, R.E.; Baldwin, R.D.; Gilbert, D.M.; Baxter, D.E.; Gillins, R.L.; Jeffries, G.L.

    1982-01-01

    During two tests in the Sodium Loop Safety Facility (W2 and P4), two systems were operated to detect delayed neutrons from exposed fuel. One monitored directly the sodium in the in-pile loop with a transit delay from the flux region of approx.2 seconds; the other conducted a sample stream of sodium to external detectors with a transit delay which could be varied from approx.10 to approx. 40 seconds. Detectors of a wide range of sensitivity were operated in pulse and current mode; DN signals varying from 2 recoil to many grams of molten fuel could be recorded reliably without saturation. During the W2 and P4 tests a continuous DN record was made. Massive fuel failure signals were observed during reactor transients in both tests, including events interpreted as fuel melting and exposure of large areas. The steady signal from the blockage in P4 was studied as a function of reactor power and sodium temperature

  1. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  2. Development of a new in vivo kit for detection of prostate specific antigen in human serum using immunoradiometric assay method

    International Nuclear Information System (INIS)

    Babaei, M. H.; Behradkia, P.; Shafii, M.; Movla, M.; Forutan, H.; Najafi, R.

    2006-01-01

    Prostate is a leading site for the cancer incidence, accounted for 31.0% of new cancer cases in men. Prostate-specific antigen is widely used in the detection and monitoring of the prostate cancer. Currently, immunoassay is used to detect Prostate-specific antigen in human serum. This technique is based on the interaction between antibody and antigen. The varied immunoassay formats and equipment to run the assays allow the users to measure the analytes rapidly, with the flexibility to run a small or a large number of samples. Among different immunoassay methods, immunoradiometric assay is a more sensitive and valuable detection approach. This study has been made in 4 parts: (1) purification of Prostate-specific antigen from seminal fluid; (2) preparation of hybridoma cells which secrete monoclonal antibody (mAb) against Prostate-specific antigen , (3) selection of pair monoclonal antibody among those antibodies, and finally (4) design of an immunoradiometric assay kit and it's quality control . The results of this study were: (1) obtaining a huge amount of Prostate-specific antigen as semi-purified and purified, that is a valuable material for preparation of standard kits; (2) preparation of 8 kinds of monoclonal antibodies; (3) finding 4 pairs of monoclonal antibodies which react with different epitopes on Prostate-specific antigen molecule; and (4) preparation of immunoradiometric assay kit for measuring Prostate-specific antigen concentration in human serum

  3. Simple Objective Detection of Human Lyme Disease Infection Using Immuno-PCR and a Single Recombinant Hybrid Antigen

    Science.gov (United States)

    Halpern, Micah D.; Molins, Claudia R.; Schriefer, Martin

    2014-01-01

    A serology-based tiered approach has, to date, provided the most effective means of laboratory confirmation of clinically suspected cases of Lyme disease, but it lacks sensitivity in the early stages of disease and is often dependent on subjectively scored immunoblots. We recently demonstrated the use of immuno-PCR (iPCR) for detecting Borrelia burgdorferi antibodies in patient serum samples that were positive for Lyme disease. To better understand the performance of the Lyme disease iPCR assay, the repeatability and variability of the background of the assay across samples from a healthy population (n = 36) were analyzed. Both of these parameters were found to have coefficients of variation of Lyme disease patient serum samples (n = 12) demonstrated a strong correlation with that of 2-tier testing. Furthermore, a simplified iPCR approach using a single hybrid antigen and detecting only IgG antibodies confirmed the 2-tier diagnosis in the Lyme disease patient serum samples (n = 12). Validation of the hybrid antigen IgG iPCR assay using a blinded panel of Lyme disease and non-Lyme disease patient serum samples (n = 92) resulted in a sensitivity of 69% (95% confidence interval [CI], 50% to 84%), compared to that of the 2-tier analysis at 59% (95% CI, 41% to 76%), and a specificity of 98% (95% CI, 91% to 100%) compared to that of the 2-tier analysis at 97% (95% CI, 88% to 100%). A single-tier hybrid antigen iPCR assay has the potential to be an improved method for detecting host-generated antibodies against B. burgdorferi. PMID:24899074

  4. Enzyme-linked immunosorbent assays for detection of equine antibodies specific to Sarcocystis neurona surface antigens.

    Science.gov (United States)

    Hoane, Jessica S; Morrow, Jennifer K; Saville, William J; Dubey, J P; Granstrom, David E; Howe, Daniel K

    2005-09-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM.

  5. A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Ying-Ying; Wang, Jun; Liu, Guodong; Wu, Hong; Wai, Chien M.; Lin, Yuehe

    2008-06-15

    We present a nanoparticle (NP) label/immunochromatographic electrochemical biosensor (IEB) for rapid and sensitive detection of prostate-specific antigen (PSA) in human serum. This IEB integrates the immunochromatographic strip with the electrochemical detector for transducing quantitative signals. The NP label, made of CdSe@ZnS, serves as a signal-amplifier vehicle. A sandwich immunoreaction was performed on the immunochromatographic strip. The captured NP labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane of the test zone. Experimental parameters (e.g., immunoreaction time, the amount of anti-PSA-NP conjugations applied) and electrochemical detection conditions (e.g., preconcentration potential and time) were optimized using this biosensor for PSA detection. The analytical performance of this biosensor was evaluated with serum PSA samples according to the “figure-of-merits” (e.g., dynamic range, reproducibility, and detection limit). The results were validated with enzyme-linked immunosorbent assay (ELISA) and show high consistency. It is found that this biosensor is very sensitive with the detection limit of 0.02 ng/mL PSA and is quite reproducible. This method is rapid, clinically accurate, and less expensive than other diagnosis tools for PSA; therefore, this IEB coupled with a portable electrochemical analyzer shows great promise for simple, sensitive, quantitative point-of-care testing of disease-related protein biomarkers.

  6. A new paradigm for Aedes spp. surveillance using gravid ovipositing sticky trap and NS1 antigen test kit.

    Science.gov (United States)

    Lau, Sai Ming; Chua, Tock H; Sulaiman, Wan-Yussof; Joanne, Sylvia; Lim, Yvonne Ai-Lian; Sekaran, Shamala Devi; Chinna, Karuthan; Venugopalan, Balan; Vythilingam, Indra

    2017-03-21

    Dengue remains a serious public health problem in Southeast Asia and has increased 37-fold in Malaysia compared to decades ago. New strategies are urgently needed for early detection and control of dengue epidemics. We conducted a two year study in a high human density dengue-endemic urban area in Selangor, where Gravid Ovipositing Sticky (GOS) traps were set up to capture adult Aedes spp. mosquitoes. All Aedes mosquitoes were tested using the NS1 dengue antigen test kit. All dengue cases from the study site notified to the State Health Department were recorded. Weekly microclimatic temperature, relative humidity (RH) and rainfall were monitored. Aedes aegypti was the predominant mosquito (95.6%) caught in GOS traps and 23% (43/187 pools of 5 mosquitoes each) were found to be positive for dengue using the NS1 antigen kit. Confirmed cases of dengue were observed with a lag of one week after positive Ae. aegypti were detected. Aedes aegypti density as analysed by distributed lag non-linear models, will increase lag of 2-3 weeks for temperature increase from 28 to 30 °C; and lag of three weeks for increased rainfall. Proactive strategy is needed for dengue vector surveillance programme. One method would be to use the GOS trap which is simple to setup, cost effective (below USD 1 per trap) and environmental friendly (i.e. use recyclable plastic materials) to capture Ae. aegypti followed by a rapid method of detecting of dengue virus using the NS1 dengue antigen kit. Control measures should be initiated when positive mosquitoes are detected.

  7. Identification of antigenic Sarcoptes scabiei proteins for use in a diagnostic test and of non-antigenic proteins that may be immunomodulatory.

    OpenAIRE

    Marjorie S Morgan; S Dean Rider; Larry G Arlian

    2017-01-01

    Background Scabies, caused by the mite, Sarcoptes scabiei, infects millions of humans, and many wild and domestic mammals. Scabies mites burrow in the lower stratum corneum of the epidermis of the skin and are the source of substances that are antigenic or modulate aspects of the protective response of the host. Ordinary scabies is a difficult disease to diagnose. Objective The goal of this project was to identify S. scabiei proteins that may be candidate antigens for use in a diagnostic test...

  8. Reactivity of various leishmanial antigens in a direct agglutination test and their value in differentiating post-kala azar dermal leishmaniasis from leprosy and other skin conditions

    NARCIS (Netherlands)

    El Harith, A.; Chowdhury, S.; Al-Masum, A.; Semião-Santos, S.; Das, P. K.; Akhter, S.; Vetter, J. C.; Haq, I.

    1996-01-01

    A direct agglutination test (DAT) for the detection of post-kala azar dermal leishmaniasis (PKDL) was evaluated in conditions that simulate the disease clinically or immunologically. A reference strain of Leishmania donovani (LEM 1399), and antigen preparations from Leishmania isolates from

  9. Evaluation of whole blood IFNgamma test using PPD and recombinant antigen challenge for diagnosis of pulmonary and extra-pulmonary tuberculosis.

    Science.gov (United States)

    Kalantri, Yatiraj; Hemvani, Nanda; Chitnis, D S

    2009-06-01

    Quantiferon TB gold (QFT-G) with recombinant antigen cocktail is well evaluated for diagnosis of pulmonary tuberculosis (PTB). However, diagnosis of extra-pulmonary tuberculosis (EPTB) is more difficult due to limitations of conventional techniques. This study compares recombinant antigens based QFT-G and low cost PPD based interferon test for the diagnosis of PTB and EPTB. IFNgamma release, with recombinant antigens and PPD, was assayed by ELISA from 140 cases of EPTB, 100 cases of PTB along with acid fast bacillus (AFB) detection, AFB culture on LJ and MGIT BACTEC. Sensitivity and specificity for QFT-G recombinant antigens was 84.29% and 96%, while for PPD based interferon was 70% and 84% for EPTB group. The sensitivity was far superior to AFB smear and culture for both the antigens. Nine samples were identified as non-tubercular mycobacteria (NTM) in the EPTB group and all were negative for QFT-G, but six of them were positive for PPD based test. Results of the study show that QFT-G using recombinant antigen is sensitive and specific for both PTB and EPTB diagnosis. The PPD based test is economic and offers comparable performance for PTB and EPTB diagnosis and also useful for diagnosis of NTM.

  10. The diagnosis of malaria infection using a solid-phase radioimmunoassay for the detection of malaria antigens

    International Nuclear Information System (INIS)

    Mackey, L.; Perrin, L.; Leemans, E.; Lambert, P.H.

    1980-01-01

    A method was devised to show that malaria parasites can be detected serologically in infected blood with a high degree of sensitivity. Using a murine malaria model, parasites were demonstrated in a solid-phase radio-immunoassay which measured antibody-binding inhibition. Lysed red blood cells (r.b.c.) were incubated with labelled specific antibody and were then reacted in antigen-coated tubes. The degree of inhibition of antibody binding in the tubes correlated with the level of parasitaemia in the test blood. Using homologous antisera the test detected infection at a level of 1 parasite/million r.b.c.. The specificity of the method was shown by comparison of antibody-binding inhibition in normal and infected r.b.c. and in r.b.c. from non-infected mice with induced reticulocytosis. The sensitivity was shown in vitro in tests of serially diluted blood of high parasitaemia and in vivo for the detection of early infection. The presence of antibody in the test blood did not significantly affect the sensitivity of parasite detection. (author)

  11. Dynamic imaging of experimental Leishmania donovani-induced hepatic granulomas detects Kupffer cell-restricted antigen presentation to antigen-specific CD8 T cells.

    Directory of Open Access Journals (Sweden)

    Lynette Beattie

    2010-03-01

    Full Text Available Kupffer cells (KCs represent the major phagocytic population within the liver and provide an intracellular niche for the survival of a number of important human pathogens. Although KCs have been extensively studied in vitro, little is known of their in vivo response to infection and their capacity to directly interact with antigen-specific CD8(+ T cells. Here, using a combination of approaches including whole mount and thin section confocal microscopy, adoptive cell transfer and intra-vital 2-photon microscopy, we demonstrate that KCs represent the only detectable population of mononuclear phagocytes within granulomas induced by Leishmania donovani infection that are capable of presenting parasite-derived peptide to effector CD8(+ T cells. This restriction of antigen presentation to KCs within the Leishmania granuloma has important implications for the identification of new candidate vaccine antigens and for the design of novel immuno-therapeutic interventions.

  12. Generation of monoclonal antibodies against prostate specific antigen (PSA) for the detection of PSA and its purification

    International Nuclear Information System (INIS)

    Acevedo Castro, Boris Ernesto

    2012-01-01

    The prostate cancer in Cuba is a problem of health (2672 diagnosed cases and 2769 deaths in 2007). Various diagnostic methods have been implemented for the detection and management of this disease, emphasizing among them (PSA) prostate-specific antigen serological determination. At this work was generated and characterized a panel of 11 antibodies (AcMs) monoclonal IgG1 detected with high affinity described major epitopes of the PSA, both in solution and attached to the test plate. From the panel obtained AcMs was the standardization of an essay type ELISA for the detection of serum total PSA (associated and free) equimolar, based on antibody monoclonal CB-PSA.4 in the coating and the CB-PSA.9 coupled with biotin as liner, with a detection limit of 0.15 ng/mL. Similarly, standardized system for detection in serum free PSA, based on the AcMs CB-PSA.4 (coating) and CB-PSA.2 coupled with biotin (liner), with a detection limit of 0.5 ng/mL. Finally, with the purpose of using PSA as standard in trials type ELISA, developed a simple method of inmunopurificación based on the AcM, CB-PSA.2, which was obtained the PSA with a purity exceeding 90%. Immunoassay Centre on the basis of the AcMs panel and the results of this study, developed and recorded two diagnostic systems for the detection of PSA in human serum. (author)

  13. Advanced Development of Leishmania Topical Skin Test Antigen

    Science.gov (United States)

    2012-09-28

    was discarded. The lysate was then heated in a water bath for 30 minutes at 60°C. The material was cooled to 10 °C, poured into sterile centrifuge...followed to assess the effectiveness of the cleaning and sanitization procedures. The filling, capping and assembly of final containers occurred in Class...40 and 80 µg doses per 0.1 mL. For all skin tests, 0.1 mL was injected intradermally into the volar surface of the forearm . Final LtSTA Report for

  14. Case of rhesus antigen weak D type 4.2. (DAR category detection

    Directory of Open Access Journals (Sweden)

    L. L. Golovkina

    2015-01-01

    Full Text Available Serological methods of Rhesus antigens identification in humans cannot identify D-antigen variants. In this article the serological characteristics of Rhesus antigen D weak type 4.2. (Category DAR are described.

  15. Variation in general practice prostate-specific antigen testing and prostate cancer outcomes

    DEFF Research Database (Denmark)

    Hjertholm, Peter; Fenger-Grøn, Morten; Vestergaard, Mogens

    2015-01-01

    Brugen af prostata-specifikt antigen (PSA) er mangedoblet i dansk almen praksis siden introduktionen i 1990’erne. Dansk Urologisk Selskab anbefaler brug af testen ved relevante symptomer og arvelig disposition, men ikke til screening. Alligevel varierer brugen af PSA-tests i almen praksis. Dette...

  16. Limitations of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) for detection of filarial antigens in serum

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Alexander, E.; Adkinson, N.F.

    1984-01-01

    The performance of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) was examined for quantitation of filarial antigens (Brugia malayi and Dirofilaria immitis) in serum from infected human and animal hosts and non-infected controls. Multiple PEG concentrations were employed to determine the level of non-specific binding (NSB) in non-exposed human sera (NEHS) containing no filarial antigen. The NSB observed when 3 different 125 I-labelled IgG antibodies were added to 26 NEHS varied 3-fold and was correlated significantly with total serum IgM (r = 0.80, P 2 fragment of the 125 I-labelled antibody was used, but the correlation of NSB with total serum IgM remained significant (r = 0.57, P < 0.01). The presence of rheumatoid factor in NEHS sera also significantly increased NSB by an average of 3-fold. These effects eliminated the assay's ability to detect in sera from infected hosts filarial antigen the presence of which could be readily demonstrated by an immunoradiometric assay. The RIPEGA's precision (intra-assay coefficient of variation (CV) = 21% at 35% Bsub(max)) and reproducibility (inter-assay CV = 29% at 35% Bsub(max)) are less satisfactory than many alternative immunoassays. (Auth.)

  17. The urinary antigen tests have high sensitivity in diagnosis of Pneumococcus caused community-acquired pneumonia posterior to antimicrobial therapy.

    Science.gov (United States)

    Chen, Ming; Zhou, Ming; Xiao, Wei; Ai, Biao; Liu, Xuezheng; Li, Yan

    2014-11-01

    Antibiotic treatment before microbiological test significant reduces the positive rate of culture methods of Streptococcus pneumoniae. The Binax NOW S. pneumoniae immunochromatographic test (ICT) has become a more commonly used procedure to diagnose S. pneumoniae from community-acquired pneumonia in adults. However, performance of this test after empirical antimicrobial therapy is uncertain. Therefore, in this prospective study, we evaluate the impact of antimicrobial therapy on sensitivity of ICT test in 487 hospitalized adult patients. The results showed that 192 (39.4 %) and 295 (60.6 %) specimens were collected before (Group 1) or after antibiotic treatment (Group 2), respectively. S. pneumoniae was detected by ICT in 21 (10.9 %) patients in the Group 1 and 39 (13.2 %) in the Group 2 and their positive rates were not different (P > 0.05). However, The positive rate of blood and pleural fluid was declined from 5.7 to 2.7 % and sputum, from 9.9 to 4.7 % after the antibiotic treatment, respectively. This study confirmed that the ICT urinary antigen test remained to have a high sensitivity for diagnosis of pneumococcal infection after empiric antibiotic treatment was started. The ICT urinary antigen test would have a potential to guide the right choice of therapy for pneumonia in adults earlier.

  18. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    Science.gov (United States)

    Alderete, J F

    1984-06-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses during the development of lesions in animals inoculated subcutaneously and it reproducibly measured the individual classes immunoglobulins directed at T vaginalis. The colorimetric assay was also suitable for showing cross reactivity between trichomonal species as well as between different strains of T vaginalis. Conditions established for monitoring antibody to trichomanads in immunised rabbits or infected mice were equally effective for human materials, such as serum or vaginal washes. Serum from experimental animals or infected people showed high concentrations of IgG, IgA, and IgM antibody to trichomonads. Only antibodies of the IgG and IgA class were detected in vaginal washes from women with acute trichomoniasis. No IgE antibody to trichomonads was found under a variety of conditions in serum samples from patients or experimental animals.

  19. ELISA testing for soy antigens in dry dog foods used in dietary elimination trials.

    Science.gov (United States)

    Willis-Mahn, Christine; Remillard, Rebecca; Tater, Kathy

    2014-01-01

    The use of elimination diet trials is necessary in the diagnosis of food allergies and intolerances. The objective of this study was to determine in vitro if four over-the-counter (OTC) dry dog foods carrying a "no soy" claim and seven veterinary therapeutic dry dog foods designed for food elimination trials were suitable for a soybean elimination trial. A 100 g sample of each diet plus one soy positive and one soy negative control diet were submitted for enzyme-linked immunosorbent assay testing to an independent food laboratory. The positive control diet contained >25 ppm soy protein antigens and the negative control contained 25 ppm. Three veterinary therapeutic diets had less than the lowest detectable limit of soy protein and four were positive (>2.5 ppm). OTC dog food diets that claim to contain "no soy" may contain high concentrations of soy protein and, therefore, should not be used in soy elimination trials in suspect food allergic dogs. The veterinary therapeutic diet selected for a soy elimination trial needs to be carefully chosen based on diet history.

  20. Development of a PMMA Electrochemical Microfluidic Device for Carcinoembryonic Antigen Detection

    Science.gov (United States)

    Van Anh, Nguyen; Van Trung, Hoang; Tien, Bui Quang; Binh, Nguyen Hai; Ha, Cao Hong; Le Huy, Nguyen; Loc, Nguyen Thai; Thu, Vu Thi; Lam, Tran Dai

    2016-05-01

    In this study, a poly(methyl methacrylate) (PMMA) microfluidic device fabricated by an inexpensive CO2 laser etching system was developed for detection of carcino-embryonic antigens (CEA). The device was capable of working in continuous mode and was designed with the aid of numerical simulation. The detection of target CEA was based on immuno-assay via magnetic particles and electrochemical sensing. The as-prepared microfluidic can be used to detect CEA at the relatively low concentration of 150 pg mL-1. The device could be reused many times, since the capture and removal of magnetic particles in the assay could be manipulated by an external magnetic field. The proposed approach appears to be suitable for high-throughput and automated analysis of large biomolecules such as tumor markers and pathogens.

  1. Detection of a human intracisternal A-type retroviral particle antigenically related to HIV

    Science.gov (United States)

    Garry, R. F.; Fermin, C. D.; Hart, D. J.; Alexander, S. S.; Donehower, L. A.; Luo-Zhang, H.

    1990-01-01

    Sjogren's syndrome is an autoimmune disease that is characterized by dryness of the mouth and eyes. The loss of salivary and lacrimal gland function is accompanied by lymphocytic infiltration. Because similar symptoms and glandular pathology are observed in certain persons infected with human immunodeficiency virus (HIV), a search was initiated for a possible retroviral etiology in this syndrome. A human intracisternal A-type retroviral particle that is antigenically related to HIV was detected in lymphoblastoid cells exposed to homogenates of salivary tissue from patients with Sjogren's syndrome. Comparison of this retroviral particle to HIV indicates that they are distinguishable by several ultrastructural, physical, and enzymatic criteria.

  2. The diagnostic accuracy of carcinoembryonic antigen to detect colorectal cancer recurrence – A systematic review

    DEFF Research Database (Denmark)

    Sørensen, Caspar G; Karlsson, William K; Pommergaard, Hans-Christian

    2016-01-01

    INTRODUCTION: Carcinoembryonic Antigen (CEA) has been used as a tumor marker in the follow-up of colorectal cancer for more than 40 years. Controversy exists regarding its diagnostic applicability due to a relatively low sensitivity and a questionable effect on mortality. The aim of this review...... was to assess the diagnostic accuracy of CEA in detecting recurrence after intended curative surgery for primary colorectal cancer. METHODS: Systematic literature searches were performed in PubMed, EMBASE and Cochrane databases, and articles were chosen based on predefined inclusion criteria. Reference lists...

  3. Antigen based detection of cystic echinococcosis in buffaloes using ELISA and Dot-EIA.

    Science.gov (United States)

    Sangaran, A; Bino Sundar, S T; Latha, Bhaskaran Ravi

    2017-03-01

    Cystic echinococcosis is caused by the larval stage of the dog tapeworm, Echinococcus granulosus . The disease is recognized as one of the world's major zoonoses affecting human beings and domestic animals apart from its economic and public health importance. Development of the cysts in the intermediate host such as buffaloes occurs in the lungs, liver and other organs. In this study, detection of circulating antigen in the diagnosis of cystic echinococcosis in buffaloes was done using enzyme linked immunosorbent assay and Dot-Enzyme immunoassay (Dot-EIA). The sensitivity and specificity were determined as 89 and 92 % respectively, whereas those of Dot-EIA were determined as 94 and 96 %.

  4. Use of Novel Recombinant Antigens in the Interferon Gamma Assay for Detection of Mycobacterium Avium Subsp. Paratuberculosis Infection in Cattle

    DEFF Research Database (Denmark)

    Mikkelsen, Heidi; Aagaard, Claus; Nielsen, Søren Saxmose

    2012-01-01

    of the study were to evaluate immunogenicity and specificity of 14 novel recombinant antigens for use in the IFN-γ assay and to assess the consistency of IFN-γ responses. The antigens used were 4 ESAT-6 family members, 4 latency proteins, 4 secreted proteins including Ag85B, 3 other antigens and PPDj......Early stage Mycobacterium avium subsp. paratuberculosis (MAP) infection can be detected by measuring antigen specific cell mediated immune responses by the interferon gamma (IFN-γ) assay. Available IFN-γ assay use purified protein derivate of Johnin (PPDj) leading to low specificity. The objectives...... of the infected and non-infected herds were significantly (Passay using PPDj did not correlate with the results using the novel antigens since 5 of the 17 animals that were positive to PPDj were...

  5. Helicobacter pylori Stool Antigen test: a reliable non-invasive test for the diagnosis of Helicobacter pylori infection in children

    NARCIS (Netherlands)

    van Doorn, O. J.; Bosman, D. K.; van't Hoff, B. W.; Taminiau, J. A.; ten Kate, F. J.; van der Ende, A.

    2001-01-01

    OBJECTIVE: To evaluate the Helicobacter pylori Stool Antigen (HpSA) test for the diagnosis of H. pylori infection in children. DESIGN AND SETTING: Prospective cohort study in an academic medical centre. PATIENTS AND METHODS: A total of 106 consecutive children who underwent gastroscopy were

  6. Early diagnosis of dengue in travelers: comparison of a novel real-time RT-PCR, NS1 antigen detection and serology.

    Science.gov (United States)

    Huhtamo, Eili; Hasu, Essi; Uzcátegui, Nathalie Y; Erra, Elina; Nikkari, Simo; Kantele, Anu; Vapalahti, Olli; Piiparinen, Heli

    2010-01-01

    The increased traveling to dengue endemic regions and the numerous epidemics have led to a rise in imported dengue. The laboratory diagnosis of acute dengue requires several types of tests and often paired samples are needed for obtaining reliable results. Although several diagnostic methods are available, proper comparative data on their performance are lacking. To compare the performance of novel methods including a novel pan-DENV real-time RT-PCR and a commercially available NS1 capture-EIA in regard to IgM detection for optimizing the early diagnosis of DENV in travelers. A panel of 99 selected early phase serum samples of dengue patients was studied by real-time RT-PCR, NS1 antigen ELISA, IgM-EIA, IgG-IFA and cell culture virus isolation. The novel real-time RT-PCR was shown specific and sensitive for detection of DENV-1-4 RNA and suitable for diagnostic use. The diagnostic rate using combination of RNA and IgM detection was 99% and using NS1 and IgM detection 95.9%. The results of RNA and NS1 antigen detection disagreed in 15.5% of samples that had only RNA or NS1 antigen detected. The diagnostic rates of early samples are higher when either RNA or NS1 antigen detection is combined with IgM detection. Besides the differences in the RNA and NS1 detection assays, the observed discrepancy of results could suggest individual variation or differences in timing of these markers in patient serum. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  7. Hybrid Synthetic Receptors on MOSFET Devices for Detection of Prostate Specific Antigen in Human Plasma.

    Science.gov (United States)

    Tamboli, Vibha K; Bhalla, Nikhil; Jolly, Pawan; Bowen, Chris R; Taylor, John T; Bowen, Jenna L; Allender, Chris J; Estrela, Pedro

    2016-12-06

    The study reports the use of extended gate field-effect transistors (FET) for the label-free and sensitive detection of prostate cancer (PCa) biomarkers in human plasma. The approach integrates for the first time hybrid synthetic receptors comprising of highly selective aptamer-lined pockets (apta-MIP) with FETs for sensitive detection of prostate specific antigen (PSA) at clinically relevant concentrations. The hybrid synthetic receptors were constructed by immobilizing an aptamer-PSA complex on gold and subjecting it to 13 cycles of dopamine electropolymerization. The polymerization resulted in the creation of highly selective polymeric cavities that retained the ability to recognize PSA post removal of the protein. The hybrid synthetic receptors were subsequently used in an extended gate FET setup for electrochemical detection of PSA. The sensor was reported to have a limit of detection of 0.1 pg/mL with a linear detection range from 0.1 pg/mL to 1 ng/mL PSA. Detection of 1-10 pg/mL PSA was also achieved in diluted human plasma. The present apta-MIP sensor developed in conjunction with FET devices demonstrates the potential for clinical application of synthetic hybrid receptors for the detection of clinically relevant biomarkers in complex samples.

  8. Detection of antibodies to the extractable nuclear antigens by enzyme linked immunosorbent assay

    International Nuclear Information System (INIS)

    Aziz, Khalil A.; Fzizal, Abul A.

    2005-01-01

    Anti-extractable nuclear antigen (ENA) antibodies are a group of autoantibodies that are directed against various components of the cell nucleus. Antibodies to these antigens are closely associated with connective tissue disease. Early diagnosis of these diseases can prove very difficult and therefore clinicians rely on the use of anti-ENA antibody testing for the exclusion. Old methods of testing are time consuming and require great skills. For these reasons clinical immunology laboratories are switching to testing for anti-ENA antibodies by enzyme linked immunosorbent assay (ELISA). The latter assays are more sensitive and require little skills. In the present study we have investigated a number of different ELISA preparations. The study was conducted at Birmingham Heartlands Hospital during the period 2003. We tested a number of ENA-positive and negative samples using 3 different commercial ELISA preparations and compared the results with traditional CCIE-assay. The present study revealed that some ELISA preparations can be more sensitive than CCIE method. Laboratories still using later method should switch to ELISA. However it is important that laboratories evaluate a long range of different ELISA preparations before selecting the most optimal one. In addition it is recommended that laboratories then audit results in order to determine true significance of such results. Finally until the true significance of ELISA generated results is known, positive ENA-results should be interpreted in conjunction with the clinical picture and this would require close liaison in between the clinical immunology laboratory and clinicians

  9. Detection of carcinoembryonic antigen using functional magnetic and fluorescent nanoparticles in magnetic separators

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H. Y., E-mail: annetsai@csmu.edu.tw [Chung Shan Medical University, Department of Applied Chemistry (China); Chang, C. Y.; Li, Y. C.; Chu, W. C.; Viswanathan, K.; Bor Fuh, C., E-mail: cbfuh@ncnu.edu.tw [National Chi Nan University, Department of Applied Chemistry (China)

    2011-06-15

    We combined a sandwich immunoassay, anti-CEA/CEA/anti-CEA, with functional magnetic ({approx}80 nm) and fluorescent ({approx}180 nm) nanoparticles in magnetic separators to demonstrate a detection method for carcinoembryonic antigen (CEA). Determination of CEA in serum can be used in clinical diagnosis and monitoring of tumor-related diseases. The CEA concentrations in samples were deduced and determined based on the reference plot using the measured fluorescent intensity of sandwich nanoparticles from the sample. The linear range of CEA detection was from 18 ng/mL to 1.8 pg/mL. The detection limit of CEA was 1.8 pg/mL. In comparison with most other detection methods, this method had advantages of lower detection limit and wider linear range. The recovery was higher than 94%. The CEA concentrations of two serum samples were determined to be 9.0 and 55 ng/mL, which differed by 6.7% (9.6 ng/mL) and 9.1% (50 ng/mL) from the measurements of enzyme-linked immunosorbent assay (ELISA), respectively. The analysis time can be reduced to one third of ELISA. This method has good potential for other biomarker detections and biochemical applications.

  10. A TeGM6-4r antigen-based immunochromatographic test (ICT) for animal trypanosomosis.

    Science.gov (United States)

    Nguyen, Thu-Thuy; Ruttayaporn, Ngasaman; Goto, Yasuyuki; Kawazu, Shin-ichiro; Sakurai, Tatsuya; Inoue, Noboru

    2015-11-01

    Animal trypanosomosis is a disease that is distributed worldwide which results in huge economic losses due to reduced animal productivity. Endemic regions are often located in the countryside where laboratory diagnosis is costly or inaccessible. The establishment of simple, effective, and accurate field tests is therefore of great interest to the farming and veterinary sectors. Our study aimed to develop a simple, rapid, and sensitive immunochromatographic test (ICT) for animal trypanosomosis utilizing the recombinant tandem repeat antigen TeGM6-4r, which is conserved amongst salivarian trypanosome species. In the specificity analysis, TeGM6-4r/ICT detected all of Trypanosoma evansi-positive controls from experimentally infected water buffaloes. As expected, uninfected controls tested negative. All sera samples collected from Tanzanian and Ugandan cattle that were Trypanosoma congolense- and/or Trypanosoma vivax-positive by microscopic examination of the buffy coat were found to be positive by the newly developed TeGM6-4r/ICT, which was comparable to results from TeGM6-4r/ELISA (kappa coefficient [κ] = 0.78). TeGM6/ICT also showed substantial agreement with ELISA using Trypanosoma brucei brucei (κ = 0.64) and T. congolense (κ = 0.72) crude antigen, suggesting the high potential of TeGM6-4r/ICT as a field diagnostic test, both for research purposes and on-site diagnosis of animal trypanosomosis.

  11. An improved haemolytic plaque assay for the detection of cells secreting antibody to bacterial antigens

    DEFF Research Database (Denmark)

    Barington, T; Heilmann, C

    1992-01-01

    Recent advances in the development of conjugate polysaccharide vaccines for human use have stimulated interest in the use of assays detecting antibody-secreting cells (AbSC) with specificity for bacterial antigens. Here we present improved haemolytic plaque-forming cell (PFC) assays detecting Ab......SC with specificity for tetanus and diphtheria toxoid as well as for Haemophilus influenzae type b and pneumococcal capsular polysaccharides. These assays were found to be less time consuming, more economical and yielded 1.9-3.4-fold higher plaque numbers than traditional Jerne-type PFC assays. In the case of anti......-polysaccharide antibodies aggregation of secreted monomeric antibody (IgG) is critical for plaque formation and increases the avidity of binding to target cells....

  12. Preparation of miniantibodies to Azospirillum brasilense Sp245 surface antigens and their use for bacterial detection.

    Science.gov (United States)

    Dykman, Lev A; Staroverov, Sergei A; Guliy, Olga I; Ignatov, Oleg V; Fomin, Alexander S; Vidyasheva, Irina V; Karavaeva, Olga A; Bunin, Viktor D; Burygin, Gennady L

    2012-01-01

    This article reports the first preparation of miniantibodies to Azospirillum brasilense Sp245 surface antigens by using a combinatorial phage library of sheep antibodies. The prepared phage antibodies were used for the first time for lipopolysaccharide and flagellin detection by dot assay, electro-optical analysis of cell suspensions, and transmission electron microscopy. Interaction of A. brasilense Sp245 with antilipopolysaccharide and antiflagellin phage-displayed miniantibodies caused the magnitude of the electro-optical signal to change considerably. The electro-optical results were in good agreement with the electron microscopic data. This is the first reported possibility of employing phage-displayed miniantibodies in bacterial detection aided by electro-optical analysis of cell suspensions.

  13. Red cell antigen prevalence predicted by molecular testing in ethnic groups of South Texas blood donors.

    Science.gov (United States)

    Aranda, Lorena I; Smith, Linda A; Jones, Scott; Beddard, Rachel

    2015-01-01

    Alloimmunization to red blood cell antigens is seen in patients receiving chronic blood transfusion. Knowing the prevalence of blood group antigens of the different ethnicities of South Texas donors can provide better management of rare blood inventory for patients in this geographical area. A total of 4369 blood donors were tested and analyzed for various antigens in the following blood group systems: ABO, Rh, Kell, Duffy, Kidd, MNS, Lutheran, Dombrock, Landsteiner-Wiener, Diego, Colton, and Scianna. Donors tested to be group 0 or A were serologically tested for the Rh (C, E, c, e) antigens. Those that tested as presumably R1R1, R2R2, or Ror were then genotyped. Donors constituted three major ethnicities: black (18.3%), Hispanic (36.3%), and Caucasian (41.1%); ethnicities comprised of Asian, American Indian, multiracial, and other accounted for the remaining donors (4.3%). The most likely common Rh phenotype for each ethnicity is as follows: black -Ror (44.4%), Hispanic -R1R1 (59.0%), and Caucasian -R1R1 (38.9%). The prevalence of Kell, Duffy, and Kidd blood group system antigens in black and Caucasian donors is comparable with published reports for the entire U.S. The black South Texas donor population had an 8.8 percent increase in prevalence of the Fy(a+b-) phenotype as compared with these published reports; the Hispanic South Texas donor population had a prevalence of 36.1 percent of the Fy(a+b-) phenotype. Regarding the Diego blood group system, the Hispanic donor population in South Texas had a prevalence of 93.5 percent for the Di(a-b+) phenotype as compared with published reports for the entire U.S. (>99.9%). The Hispanic population had a prevalence of 7.9 percent of donors testing as M-N+S-s+ as compared with 20.2 percent and 15.6 percent for black and Caucasian donors, respectively. This study helped us determine the prevalence of each of the blood group antigens in the South Texas donor population to establish and maintain adequate rare inventory of

  14. Carcinoma-associated antigens

    International Nuclear Information System (INIS)

    Bartorelli, A.; Accinni, R.

    1981-01-01

    This invention relates to novel antigens associated with breast carcinoma, anti-sera specific to said antigens, 125 I-labeled forms of said antigens and methods of detecting said antigens in serum or plasma. The invention also relates to a diagnostic kit containing standardised antigens or antisera or marked forms thereof for the detection of said antigens in human blood, serum or plasma. (author)

  15. Detection of Potentially Diagnostic Leishmania Antigens with Western Blot Analysis of Sera from Patients with Cutaneous and Visceral Leishmaniases

    Directory of Open Access Journals (Sweden)

    Seyyed Javad SEYYEDTABAEI

    2017-06-01

    Full Text Available Background: Visceral leishmaniasis (VL and cutaneous leishmaniasis (CL are important public health problems in Iran. We aimed to evaluate the diagnostic potential of Western blot (WB compared with indirect immunofluorescence test (IFAT to serodiagnosis of leishmaniasis.Methods: This study was performed from 2010-2014 and participants were different parts of Iran. Serum samples were obtained from 43 patients with proven CL, 33 patients with proven VL, 39 patients with other parasitic diseases and 23 healthy individuals. Results: WB sensitivity for CL and VL was 100% and 91%, compared to IFA 4.6% and 87.8%, respectively. Sera from patients with CL and VL recognized numerous antigens with molecular weights ranging from 14 to 68 kDa and 12 to 94 kDa, respectively. The most sensitive antigens were 14 and 16 kDa for CL recognized by 100% of the sera from patients with proven CL and 12, 14 and 16 kDa for VL, recognized by 63.6%, 100% and 63.6% of the sera from patients with proven VL respectively. WB analysis is more sensitive than IFAT for the diagnosis of leishmaniasis particularly in cases of cutaneous leishmaniasis. The 12, 14 and 16 kDa can be valuable diagnostic molecules for serodiagnosis of leishmaniasis because at least two immunogenic molecules were simultaneously detected by all patient sera, as well as produced antibodies against these antigens have no cross-reactivity with other control groups.Conclusion: WB could be useful for screening and serodiagnosis of CL and VL in epidemiologic studies in endemic areas.

  16. Antigen-Dissociation from Antibody-Modified Nanotransistor Sensor Arrays as a Direct Biomarker Detection Method in Unprocessed Biosamples.

    Science.gov (United States)

    Krivitsky, Vadim; Zverzhinetsky, Marina; Patolsky, Fernando

    2016-10-12

    The detection of biomolecules is critical for a wide spectrum of applications in life sciences and medical diagnosis. Nonetheless, biosamples are highly complex solutions, which contain an enormous variety of biomolecules, cells, and chemical species. Consequently, the intrinsic chemical complexity of biosamples results in a significant analytical background noise and poses an immense challenge to any analytical measurement, especially when applied without prior efficient separation and purification steps. Here, we demonstrate the application of antigen-dissociation regime, from antibody-modified Si-nanowire sensors, as a simple and effective direct sensing mechanism of biomarkers of interest in complex biosamples, such as serum and untreated blood, which does not require ex situ time-consuming biosample manipulation steps, such as centrifugation, filtering, preconcentration, and desalting, thus overcoming the detrimental Debye screening limitation of nanowire-based biosensors. We found that two key parameters control the capability to perform quantitative biomarkers analysis in biosamples: (i) the affinity strength (k off rate) of the antibody-antigen recognition pair, which dictates the time length of the high-affinity slow dissociation subregime, and (ii) the "flow rate" applied during the solution exchange dissociation step, which controls the time width of the low-affinity fast-dissociation subregime. Undoubtedly, this is the simplest and most convenient approach for the SiNW FET-based detection of antigens in complex untreated biosamples. The lack of ex situ biosample manipulation time-consuming processes enhances the portability of the sensing platform and reduces to minimum the required volume of tested sample, as it allows the direct detection of untreated biosamples (5-10 μL blood or serum), while readily reducing the detection cycle duration to less than 5 min, factors of great importance in near-future point-of-care medical applications. We believe

  17. A self-amplified transistor immunosensor under dual gate operation: highly sensitive detection of hepatitis B surface antigen

    Science.gov (United States)

    Lee, I.-K.; Jeun, M.; Jang, H.-J.; Cho, W.-J.; Lee, K. H.

    2015-10-01

    Ion-sensitive field-effect transistors (ISFETs), although they have attracted considerable attention as effective immunosensors, have still not been adopted for practical applications owing to several problems: (1) the poor sensitivity caused by the short Debye screening length in media with high ion concentration, (2) time-consuming preconditioning processes for achieving the highly-diluted media, and (3) the low durability caused by undesirable ions such as sodium chloride in the media. Here, we propose a highly sensitive immunosensor based on a self-amplified transistor under dual gate operation (immuno-DG ISFET) for the detection of hepatitis B surface antigen. To address the challenges in current ISFET-based immunosensors, we have enhanced the sensitivity of an immunosensor by precisely tailoring the nanostructure of the transistor. In the pH sensing test, the immuno-DG ISFET showed superior sensitivity (2085.53 mV per pH) to both standard ISFET under single gate operation (58.88 mV per pH) and DG ISFET with a non-tailored transistor (381.14 mV per pH). Moreover, concerning the detection of hepatitis B surface antigens (HBsAg) using the immuno-DG ISFET, we have successfully detected trace amounts of HBsAg (22.5 fg mL-1) in a non-diluted 1× PBS medium with a high sensitivity of 690 mV. Our results demonstrate that the proposed immuno-DG ISFET can be a biosensor platform for practical use in the diagnosis of various diseases.Ion-sensitive field-effect transistors (ISFETs), although they have attracted considerable attention as effective immunosensors, have still not been adopted for practical applications owing to several problems: (1) the poor sensitivity caused by the short Debye screening length in media with high ion concentration, (2) time-consuming preconditioning processes for achieving the highly-diluted media, and (3) the low durability caused by undesirable ions such as sodium chloride in the media. Here, we propose a highly sensitive immunosensor

  18. Screen Printed Carbon Electrode Based Electrochemical Immunosensor for the Detection of Dengue NS1 Antigen

    Directory of Open Access Journals (Sweden)

    Om Parkash

    2014-11-01

    Full Text Available An electrochemical immunosensor modified with the streptavidin/biotin system on screen printed carbon electrodes (SPCEs for the detection of the dengue NS1 antigen was developed in this study. Monoclonal anti-NS1 capture antibody was immobilized on streptavidin-modified SPCEs to increase the sensitivity of the assay. Subsequently, a direct sandwich enzyme linked immunosorbent assay (ELISA format was developed and optimized. An anti-NS1 detection antibody conjugated with horseradish peroxidase enzyme (HRP and 3,3,5,5'-tetramethybezidine dihydrochloride (TMB/H2O2 was used as an enzyme mediator. Electrochemical detection was conducted using the chronoamperometric technique, and electrochemical responses were generated at −200 mV reduction potential. The calibration curve of the immunosensor showed a linear response between 0.5 µg/mL and 2 µg/mL and a detection limit of 0.03 µg/mL. Incorporation of a streptavidin/biotin system resulted in a well-oriented antibody immobilization of the capture antibody and consequently enhanced the sensitivity of the assay. In conclusion, this immunosensor is a promising technology for the rapid and convenient detection of acute dengue infection in real serum samples.

  19. Evaluation of a Direct Immunofluorescent Assay and/or Conjunctival Cytology for Detection of Canine Distemper Virus Antigen.

    Science.gov (United States)

    Athanasiou, Labrini V; Kantere, Maria C; Kyriakis, Constantinos S; Pardali, Dimitra; Adamama Moraitou, Katerina; Polizopoulou, Zoe S

    2018-04-01

    Canine distemper is a common and potentially lethal multisystemic disease caused by the Canine distemper virus (CDV). We evaluated the diagnostic performance of direct immunofluorescent assay (FA) and cytology to detect CDV antigen in conjunctival cells compared with an established polymerase chain reaction (PCR) detection assay used as a gold standard for CDV diagnosis. Samples were collected from 57 young dogs presenting with central nervous system signs compatible with distemper disease. Exfoliative epithelial cells were collected from the right and left conjunctiva of each animal using nylon-bristled cytobrushes for cytology and cotton swabs for FA and PCR. For the direct FA, samples were stained with anti-CDV polyclonal antiserum conjugated to fluorescein isothiocyanate and imaged using a fluorescent microscope. Out of 57 dogs tested, 19 were PCR positive (15 positive in direct FA and 4 positive in cytology, including one that was negative by PCR), whereas 37 dogs were negative in all methods. A good agreement was observed between the FA and PCR, with a κ-value of 0.833 (95% CI: 0.678-0.989). Meanwhile, there was poor agreement between cytology and PCR (κ-value of 0.164; 95% CI: -0.045 to 0.373) and a fair agreement between FA and cytology (κ-value of 0.231; 95% CI: -0.026 to 0.487). Our results indicated a poor performance of cytology for the detection of CDV antigen. In contrast, FA is a 100% specific and an adequately sensitive assay (sensitivity: 78.95%, negative likelihood ratio: 0.21, 95% CI: 0.09-0.50) for antemortem diagnosis of canine distemper.

  20. Development and evaluation of a truncated recombinant NS3 antigen-based indirect ELISA for detection of pestivirus antibodies in sheep and goats.

    Science.gov (United States)

    Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya

    2015-01-01

    The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.

  1. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    Science.gov (United States)

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  2. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    Science.gov (United States)

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  3. Fluorescence-based endoscopic imaging of Thomsen-Friedenreich antigen to improve early detection of colorectal cancer.

    Science.gov (United States)

    Sakuma, Shinji; Yu, James Y H; Quang, Timothy; Hiwatari, Ken-Ichiro; Kumagai, Hironori; Kao, Stephanie; Holt, Alex; Erskind, Jalysa; McClure, Richard; Siuta, Michael; Kitamura, Tokio; Tobita, Etsuo; Koike, Seiji; Wilson, Kevin; Richards-Kortum, Rebecca; Liu, Eric; Washington, Kay; Omary, Reed; Gore, John C; Pham, Wellington

    2015-03-01

    Thomsen-Friedenreich (TF) antigen belongs to the mucin-type tumor-associated carbohydrate antigen. Notably, TF antigen is overexpressed in colorectal cancer (CRC) but is rarely expressed in normal colonic tissue. Increased TF antigen expression is associated with tumor invasion and metastasis. In this study, we sought to validate a novel nanobeacon for imaging TF-associated CRC in a preclinical animal model. We developed and characterized the nanobeacon for use with fluorescence colonoscopy. In vivo imaging was performed on an orthotopic rat model of CRC. Both white light and fluorescence colonoscopy methods were utilized to establish the ratio-imaging index for the probe. The nanobeacon exhibited specificity for TF-associated cancer. Fluorescence colonoscopy using the probe can detect lesions at the stage which is not readily confirmed by conventional visualization methods. Further, the probe can report the dynamic change of TF expression as tumor regresses during chemotherapy. Data from this study suggests that fluorescence colonoscopy can improve early CRC detection. Supplemented by the established ratio-imaging index, the probe can be used not only for early detection, but also for reporting tumor response during chemotherapy. Furthermore, since the data obtained through in vivo imaging confirmed that the probe was not absorbed by the colonic mucosa, no registered toxicity is associated with this nanobeacon. Taken together, these data demonstrate the potential of this novel probe for imaging TF antigen as a biomarker for the early detection and prediction of the progression of CRC at the molecular level. © 2014 UICC.

  4. On the importance of controlling film architecture in detecting prostate specific antigen

    Science.gov (United States)

    Graça, Juliana Santos; Miyazaki, Celina Massumi; Shimizu, Flavio Makoto; Volpati, Diogo; Mejía-Salazar, J. R.; Oliveira, Osvaldo N., Jr.; Ferreira, Marystela

    2018-03-01

    Immunosensors made with nanostructured films are promising for detecting cancer biomarkers, even at early stages of the disease, but this requires control of film architecture to preserve the biological activity of immobilized antibodies. In this study, we used electrochemical impedance spectroscopy (EIS) to detect Prostate Specific Antigen (PSA) with immunosensors produced with layer-by-layer (LbL) films containing anti-PSA antibodies in two distinct film architectures. The antibodies were either adsorbed from solutions in which they were free, or from solutions where they were incorporated into liposomes of dipalmitoyl phosphatidyl glycerol (DPPG). Incorporation into DPPG liposomes was confirmed with surface plasmon resonance experiments, while the importance of electrostatic interactions on the electrical response was highlighted using the Finite Difference Time-Domain Method (FDTD). The sensitivity of both architectures was sufficient to detect the threshold value to diagnose prostate cancer (ca. 4 ng mL-1). In contrast to expectation, the sensor with the antibodies incorporated into DPPG liposomes had lower sensitivity, though the range of concentrations amenable to detection increased, according to the fitting of the EIS data using the Langmuir-Freundlich adsorption model. The performance of the two film architectures was compared qualitatively by plotting the data with a multidimensional projection technique, which constitutes a generic approach for optimizing immunosensors and other types of sensors.

  5. Gold nanoparticle-based low limit of detection Love wave biosensor for carcinoembryonic antigens.

    Science.gov (United States)

    Li, Shuangming; Wan, Ying; Su, Yan; Fan, Chunhai; Bhethanabotla, Venkat R

    2017-09-15

    In this work, a Love wave biosensing platform is described for detecting cancer-related biomarker carcinoembryonic antigen (CEA). An ST 90°-X quartz Love wave device with a layer of SiO 2 waveguide was combined with gold nanoparticles (Au NPs) to amplify the mass loading effect of the acoustic wave sensor to achieve a limit of detection of 37pg/mL. The strategy involves modifying the Au NPs with anti-CEA antibody conjugates to form nanoprobes in a sandwich immunoassay. The unamplified detection limit of the Love wave biosensor is 9.4ng/mL. This 2-3 order of magnitude reduction in the limit of detection brings the SAW platform into the range useful for clinical diagnosis. Measurement electronics and microfluidics are easily constructed for acoustic wave biosensors, such as the Love wave device described here, allowing for robust platforms for point of care applications for cancer biomarkers in general. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Immunodiagnosis of fascioliasis using sandwich enzyme-linked immunosorbent assay for detection of Fasciola gigantica paramyosin antigen

    Science.gov (United States)

    Abou-Elhakam, Hany Mohamed Adel; Bauomy, Ibraheem Rabia; El Deeb, Somaya Osman; El Amir, Azza Mohamed

    2013-01-01

    Background: Many immunological techniques have been developed over years using the different Fasciola antigens for diagnosis of parasitic infection and to replace the parasitological techniques, which are time consuming and usually lack sensitivity and reproducibility. Materials and Methods: In this study, Fasciola gigantica paramyosin (Pmy) antigen was early detected in cattle sera using sandwich enzyme-linked immunosorbent assay (ELISA), to evaluate the Pmy antigen performance in diagnosis. This work was conducted on 135 cattle blood samples, which were classified according to parasitological investigation into, healthy control (30), fascioliasis (75), and other parasites (30) groups. Results: The sensitivity of Sandwich ELISA was 97.33%, and the specificity was 95%, in comparison with parasitological examination, which recorded 66.66% sensitivity and 100% specificity, respectively. Conclusions: It was clear that the native F. gigantica Pmy is considered as a powerful antigen in early immunodiagnosis of fascioliasis, using a highly sensitive and specific sandwich ELISA technique. PMID:23961441

  7. A comparison of labelled antibody methods for the detection of virus antigens in cell monolayers

    International Nuclear Information System (INIS)

    Oram, J.D.; Crooks, A.J.

    1979-01-01

    A number of labelled antibody methods have been applied to the detection of Semliki Forest virus antigens after replication of the virus in monolayers of host cells in multi-well polystyrene plates. The importance of several reaction variables has been investigated and the sensitivity of the methods compared for different periods of virus replication. Direct assays with radio-labelled antibody (RLA) and indirect assays peroxidase-antiperoxidase complexes (PAP) were equally sensitive. Direct and indirect assays using enzyme-linked antibodies (ELA) were slightly less sensitive than the direct RLA and PAP methods but were more sensitive than the indirect RLA or fluorescent antibody (FLA) methods. Direct assays using ELA were more rapid and easier to perform than the other assay methods. (Auth.)

  8. Selection of tests for outlier detection

    NARCIS (Netherlands)

    Bossers, H.C.M.; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    Integrated circuits are tested thoroughly in order to meet the high demands on quality. As an additional step, outlier detection is used to detect potential unreliable chips such that quality can be improved further. However, it is often unclear to which tests outlier detection should be applied and

  9. Large-scale detection of antigen-specific T cells using peptide-MHC-I multimers labeled with DNA barcodes

    DEFF Research Database (Denmark)

    Bentzen, Amalie Kai; Marquard, Andrea Marion; Lyngaa, Rikke Birgitte

    2016-01-01

    -major histocompatibility complex (MHC) multimers labeled with individual DNA barcodes to screen >1,000 peptide specificities in a single sample, and detect low-frequency CD8 T cells specific for virus- or cancer-restricted antigens. When analyzing T-cell recognition of shared melanoma antigens before and after adoptive...... cell therapy in melanoma patients, we observe a greater number of melanoma-specific T-cell populations compared with cytometry-based approaches. Furthermore, we detect neoepitope-specific T cells in tumor-infiltrating lymphocytes and peripheral blood from patients with non-small cell lung cancer...

  10. Detection of Hepatitis B Virus Antigens in Paraffin-embedded Liver Specimens from the Amazon Region, Brazil

    Directory of Open Access Journals (Sweden)

    Simonetti SRR

    2002-01-01

    Full Text Available Hepatic viscerotomy of paraffin-preserved old specimens, collected in the period from 1934 to 1967, were analyzed by immunohistochemical assays to detect hepatitis B, hepatitis D, dengue and yellow fever virus antigens. The material belongs to the Yellow Fever Collection, Department of Pathology, Instituto Oswaldo Cruz, Rio de Janeiro, Brazil and the cases were diagnosed at that time according to clinical aspects and histopathological findings reporting viral hepatitis, yellow fever, focal necrosis and hepatic atrophy. From the 79 specimens, 69 were collected at the Labrea Region and the other 10 in different other localities in the Amazon Region. The five micra thick histological slices were analyzed for the presence of hepatitis B surface antigen (HBsAg and hepatitis B core antigen (HBcAg by immunoperoxidase technique. An immunofluorescence assay was applied to the detection of hepatitis D, yellow fever and dengue virus antigens. Nine (11.4% histological samples were HBsAg reactive and 5 (6.3% were HBcAg reactive. The oldest reactive sample was from 1934. Viral antigens related to the other pathologies were not detected in this study. Our results confirm that the methodology described may be used to elucidate the aetiology of hepatitis diseases even after a long time of conservation of the specimens.

  11. Development of a double-antibody radioimmunoassay for detecting ovarian tumor-associated antigen fraction OCA in plasma

    International Nuclear Information System (INIS)

    Knauf, S.; Urbach, G.I.

    1978-01-01

    Ovarian tumor-associated antigen isolated from human tumor tissue was shown to have a different mobility from that of carcinoembryonic antigen (CEA) in both acrylamide gel electrophoresis and immunoelectrophoresis in agarose. The ovarian tumor antigen is composed of six species with different electrophoretic mobility in acrylamide gel electrophoresis. Three of these species were detected in Sephadex G-100 ovarian fraction OCA (from the void volume peak) and the other three species of lower apparent molecular weight were detected in fraction OCD (from the second peak). Fractions OCA and OCD did not share common antigenic determinants as determined by immunodiffusion. CEA was shown to share antigenic determinants with both OCA and OCD. A double-antibody radioimmunoassay capable of detecting nanogram quantities of plasma OCA was developed. In a preliminary study of ovarian cancer patients, OCA appeared to be a more sensitive marker for ovarian cancer than CEA. There was virtually no correlation (r 2 = 0.1) between OCA and CEA levels in these patients, as determined by radioimmunoassay

  12. Detection of target staphylococcal enterotoxin B antigen in orange juice and popular carbonated beverages using antibody-dependent antigen-capture assays.

    Science.gov (United States)

    Principato, MaryAnn; Njoroge, Joyce M; Perlloni, Andrei; O' Donnell, Michael; Boyle, Thomas; Jones, Robert L

    2010-10-01

    There is a critical need for qualitative and quantitative methodologies that provide the rapid and accurate detection of food contaminants in complex food matrices. However, the sensitivity of the assay can be affected when antigen-capture is applied to certain foods or beverages that are extremely acidic. This study was undertaken to assess the effects of orange juice and popular carbonated soft drink upon the fidelity of antibody-based antigen-capture assays and to develop simple approaches that could rescue assay performance without the introduction of additional or extensive extraction procedures. We examined the effects of orange juice and a variety of popular carbonated soft drink beverages upon a quantitative Interleukin-2 (IL-2) enzyme-linked immunosorbent assay (ELISA) assay system and a lateral flow device (LFD) adapted for the detection of staphylococcal enterotoxin B (SEB) in foods. Alterations in the performance and sensitivity of the assay were directly attributable to the food matrix, and alterations in pH were especially critical. The results demonstrate that approaches such as an alteration of pH and the use of milk as a blocking agent, either singly or in combination, will partially rescue ELISA performance. The same approaches permit lateral flow to efficiently detect antigen. Practical Application: The authors present ways to rescue an ELISA assay compromised by acidity in beverages and show that either the alteration of pH, or the use of milk as a blocking agent are not always capable of restoring the assay to its intended efficiency. However, the same methods, when employed with lateral flow technology, are rapid and extremely successful.

  13. Utility of PCR, Culture, and Antigen Detection Methods for Diagnosis of Legionellosis.

    Science.gov (United States)

    Chen, Derrick J; Procop, Gary W; Vogel, Sherilynn; Yen-Lieberman, Belinda; Richter, Sandra S

    2015-11-01

    The goal of this retrospective study was to evaluate the performance of different diagnostic tests for Legionnaires' disease in a clinical setting where Legionella pneumophila PCR had been introduced. Electronic medical records at the Cleveland Clinic were searched for Legionella urinary antigen (UAG), culture, and PCR tests ordered from March 2010 through December 2013. For cases where two or more test methods were performed and at least one was positive, the medical record was reviewed for relevant clinical and epidemiologic factors. Excluding repeat testing on a given patient, 19,912 tests were ordered (12,569 UAG, 3,747 cultures, and 3,596 PCR) with 378 positive results. The positivity rate for each method was 0.4% for culture, 0.8% for PCR, and 2.7% for UAG. For 37 patients, at least two test methods were performed with at least one positive result: 10 (27%) cases were positive by all three methods, 16 (43%) were positive by two methods, and 11 (30%) were positive by one method only. For the 32 patients with medical records available, clinical presentation was consistent with proven or probable Legionella infection in 84% of the cases. For those cases, the sensitivities of culture, PCR, and UAG were 50%, 92%, and 96%, respectively. The specificities were 100% for culture and 99.9% for PCR and UAG. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  14. The diagnosis of symptomatic acute antiretroviral syndrome during the window period with antigen/antibody testing and HIV viral load

    Directory of Open Access Journals (Sweden)

    Daniel O. Griffin

    Full Text Available Despite much focus on moving toward a cure to end the epidemic human immunodeficiency virus (HIV epidemic there are still thousands of new infections occurring every year in the United States. Although there is ongoing transmission of HIV in the United States and a growing population of people living with HIV, the acute presentation of HIV infection can be challenging to diagnose and is often not considered when patients present to healthcare providers. Although in certain states there are HIV testing laws that require that all persons between the ages of 13 and 64 be offered HIV testing in an opt-out approach, many patient presenting with an acute illness, that would warrant diagnostic testing for HIV, leave without having an HIV test performed for either diagnostic or screening purposes.We describe the case of a woman who presented to medical attention with symptoms later confirmed to be due to acute HIV infection. She was initially discharged from the hospital and only underwent HIV testing with confirmation of her diagnosis after readmission. We describe the algorithm where fourth generation testing combined with HIV viral load testing allowed for the diagnosis of acute HIV prior to the development of a specific immunoglobulin response. Consideration of this diagnosis, improved HIV screening, and understanding of the use of antigen/antibody screening tests, combined with Multispot and HIV viral RNA detection, when appropriate, can allow for early diagnosis of HIV before progression of disease and before undiagnosed patient spread the infection to new contacts.

  15. Comparison of Real Time Polymerase Chain Reaction with Microscopy and Antigen Detection Assay for the Diagnosis of Malaria

    International Nuclear Information System (INIS)

    Khan, S. A.; Ahmed, S.; Khan, F. A.; Shamshad, G. U.; Joyia, Z.; Mushahid, N.; Saeed, S.

    2013-01-01

    Objective: To determine the sensitivity of a real time polymerase chain reaction (PCR) for malaria diagnosis and to compare its accuracy with microscopy and an antigen based rapid diagnostic test (OptiMal). Study Design: Cross-sectional analytical study. Place and Duration of Study: Military Hospital, Armed Forces Institute of Transfusion and Armed Forces Institute of Pathology, Rawalpindi, from July to December 2011. Methodology: Venous blood samples of 300 clinically suspected patients of malaria were tested for malaria parasite by microscopy and OptiMal; and malaria parasite index was calculated for the positive samples. Plasmodium genus specific real time PCR was performed on all specimens, targeting small subunit rRNA gene. Diagnostic accuracy of three tests was compared and cost analysis was done. Results: Out of 300 patients, malaria parasite was detected in 110, 106 and 123 patients by microscopy, OptiMAL and PCR respectively. Real time PCR was 100% sensitive while microscopy and OptiMal had sensitivity of 89.4% and 86.2% respectively. All methods were 100% specific. The cost per test was calculated to be 0.2, 2.75 and 3.30 US dollar by microscopy, OptiMal and PCR respectively, excluding the once capital cost on PCR equipment. Conclusion: Genus specific real time PCR for the diagnosis of malaria was successfully established as a highly sensitive and affordable technology that should be incorporated in the diagnostic algorithm in this country. (author)

  16. Diagnosis of Fasciola gigantica infection in cattle using capture-ELISA assay for detecting antigen in faeces

    Directory of Open Access Journals (Sweden)

    Sarwitri Endah Estuningsih

    2006-10-01

    Full Text Available Capture-ELISA assay is a diagnosis for antigen detection in the serum or faeces using polyclonal or monoclonal antibodies. The purpose of this study was to determine the sensitivity and specificity of capture-ELISA assay using polyclonal antibody for diagnosing Fasciola gigantica infection in cattle by detecting antigen in the faeces. In this study, faecal samples and livers were collected from 141 cattle slaughtered in the abattoir in Jakarta. From each animal, liver was processed for liver flukes count and the corresponding faecal sample was analysed for coproantigen. The result of capture-ELISA assay for antigen detection showed that from 85 cattle infected with Fasciola gigantica, 83 had OD > 0.52 (range from 0.52-1.39 and 2 cattle had OD < 0.52 (range from 0.17-0.51. The sensitivity and specificity of the assay were 97.6% and 92.8% respectively. The assay also able to detect 50 ng/ml of antigen in faecal supernatant. It suggests that this assay will have the advantage over the other methods on its ability to detect the active infection. Collection of faeces, rather than serum, will allow a more cost-effective and adaptable method.

  17. Comparative testing of six antigen-based malaria vaccine candidates directed toward merozoite-stage Plasmodium falciparum

    DEFF Research Database (Denmark)

    Arnot, David E; Cavanagh, David R; Remarque, Edmond J

    2008-01-01

    Immunogenicity testing of Plasmodium falciparum antigens being considered as malaria vaccine candidates was undertaken in rabbits. The antigens compared were recombinant baculovirus MSP-1(19) and five Pichia pastoris candidates, including two versions of MSP-1(19), AMA-1 (domains I and II), AMA-1......G concentrations. The two P. pastoris-produced MSP-1(19)-induced IgGs conferred the lowest growth inhibition. Comparative analysis of immunogenicity of vaccine antigens can be used to prioritize candidates before moving to expensive GMP production and clinical testing. The assays used have given discriminating...

  18. Applicability of direct agglutination test (DAT) at a rural health setting in Bangladesh and feasibility of local antigen production.

    Science.gov (United States)

    Chowdhury, M S; al Masum, A; al Karim, E; Semiáo-Santos, S; Rahman, K M; Ar-Rashid, H; el Harith, A

    1993-01-01

    As part of a large-scale sero-epidemiological survey on visceral leishmaniasis (VL) carried out in Mymensingh district of Bangladesh, applicability of DAT was assessed at the level of a rural health setting in Trishal (upazila) subdistrict. Despite the relatively less optimal conditions encountered, 5854 inhabitants from 7 villages appendant to Trishal were assessed for VL. The demographic distribution for sero-positivity obtained at the rural setting was comparable to that found by DAT as executed at the central laboratory (IEDC&R, Dhaka) on 9619 inhabitants from the same upazila. The overall sero-prevalence rate was 4.4% compared to 3.7% obtained in the population assessed at the central laboratory. In either study, similar VL prevalence rates of 2.1% were obtained in the male populations. Irrespective of sex, younger population ( or = 90 years (1.4% and 1.8%). Local production of DAT antigen employing an authochtonus L. donovani isolate was attempted at the central laboratory (IEDC&R) in Dhaka. By comparison with the reference antigen, titres obtained in all 33 VL sera tested were equally higher (1:6400- > or =: 51200) than in 35 out of 38 negative controls (< or = 1:400-1:1600). A comparable level of reactivity was also obtained in 53 VL and 52 negative control sera using a well characterized L. donovani strain (MHOM/IN/80/D88) from India. However, unlike the reference strain, titres obtained in 7 endemic controls were significantly higher with the authochtonous and homologous antigen (1:3200 - 1:6400) than with the reference (1:100 - 1:1600). The results signify the advantage of employing indigenous L. donovani isolates to further improve DAT sensitivity for detection of early and sub-clinical VL.

  19. Microfluidic-integrated patterned ITO immunosensor for rapid detection of prostate-specific membrane antigen biomarker in prostate cancer.

    Science.gov (United States)

    Seenivasan, Rajesh; Singh, Chandra K; Warrick, Jay W; Ahmad, Nihal; Gunasekaran, Sundaram

    2017-09-15

    An optically transparent patterned indium tin oxide (ITO) three-electrode sensor integrated with a microfluidic channel was designed for label-free immunosensing of prostate-specific membrane antigen (PSMA), a prostate cancer (PCa) biomarker, expressed on prostate tissue and circulating tumor cells but also found in serum. The sensor relies on cysteamine capped gold nanoparticles (N-AuNPs) covalently linked with anti-PSMA antibody (Ab) for target specificity. A polydimethylsiloxane (PDMS) microfluidic channel is used to efficiently and reproducibly introduce sample containing soluble proteins/cells to the sensor. The PSMA is detected and quantified by measuring the change in differential pulse voltammetry signal of a redox probe ([Fe(CN) 6 ] 3- /[Fe(CN) 6 ] 4- ) that is altered upon binding of PSMA with PSMA-Ab immobilized on N-AuNPs/ITO. Detection of PSMA expressing cells and soluble PSMA was tested. The limit of detection (LOD) of the sensor for PSMA-based PCa cells is 6/40µL (i.e., 150 cells/mL) (n=3) with a linear range of 15-400 cells/40µL (i.e., 375-10,000 cells/mL), and for the soluble PSMA is 0.499ng/40µL (i.e., 12.5ng/mL) (n=3) with the linear range of 0.75-250ng/40µL (i.e., 19-6250ng/mL), both with an incubation time of 10min. The results indicate that the sensor has a suitable sensitivity and dynamic range for routine detection of PCa circulating tumor cells and can be adapted to detect other biomarkers/cancer cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Enhanced target-specific signal detection using an Escherichia coli lysate in multiplex microbead immunoassays with E. coli-derived recombinant antigens.

    Science.gov (United States)

    Crestani, Sandra; Leitolis, Amanda; Lima, Lucianna Freitas Oliveira; Krieger, Marco A; Foti, Leonardo

    2016-08-01

    Diverse techniques have been developed to analyze antibody-mediated responses to infections. However, the most common tests, i.e., enzyme-linked immunosorbent assays, require separate reactions for each antigen and consequently necessitate large sample volumes. Luminex technology allows the detection of multiple antibodies in a single experiment, but nonspecific binding can impair the results. Therefore, we examined the use of Escherichia coli lysates to reduce nonspecific binding and improve the results of liquid microarrays based on Luminex technology. Anti-bacteria antibodies were detected in human serum samples, as evidenced by high median fluorescence intensity (MFI) in assays performed with paramagnetic microspheres coupled with E. coli lysates. Moreover, the addition of an E. coli lysate as a blocker reduced the nonspecific binding of antigens produced by E. coli in a concentration-dependent manner. Tris-HCl reduced MFI values in negative samples, but did not affect MFI for positive samples. For microspheres coupled with different antigens, an E. coli lysate blocker significantly improved the fluorescence signals from positive samples. The addition of Tris-HCl and the E. coli lysate induced antigen-specific differences in MFI. This combination of the E. coli lysate blocker and Tris-HCl yielded a statistically significant improvement in MFI in the assays for Chagas disease and hepatitis C virus samples. However, for the Treponema pallidum p47 antigen improvement in MFI was only observed for the preparation with the E. coli blocker at a concentration of 3%. In conclusion, the addition of an E. coli lysate and Tris-HCl to the microarray assay reduced the nonspecific binding of human anti-bacteria antibodies and, therefore, increased the specific MFI. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Metal-organic gel enhanced fluorescence anisotropy for sensitive detection of prostate specific antigen

    Science.gov (United States)

    Zhao, Ting Ting; Peng, Zhe Wei; Yuan, Dan; Zhen, Shu Jun; Huang, Cheng Zhi; Li, Yuan Fang

    2018-03-01

    In this contribution, we demonstrated that Cu-based metal-organic gel (Cu-MOG) was able to serve as a novel amplification platform for fluorescence anisotropy (FA) assay for the first time, which was confirmed by the sensitive detection of a common cancer biomarker, prostate specific antigen (PSA). The dye-labeled probe aptamer (PA) product was adsorbed onto the benzimidazole derivative-containing Cu-MOG via electrostatic incorporation and strong π-π stacking interactions, which significantly increased the FA value due to the enlargement of the molecular volume of the PA/Cu-MOG complex. With the introduction of target PSA, the FA value was obviously decreased on account of the specific recognition between PSA and PA which resulted in the detachment of PA from the surface of MOG. The linear range was from 0.5-8 ng/mL, with a detection limit of 0.33 ng/mL. Our work has thus helped to demonstrate promising application of MOG material in the fields of biomolecules analysis and disease diagnosis.

  2. Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening.

    Science.gov (United States)

    Li, Jun; Zhao, Guixiang; Hall, Ingrid J

    2015-08-01

    For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (ptesting with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients' values and preferences in decisions about PSA testing. Published by Elsevier Inc.

  3. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    Science.gov (United States)

    Docters, E. H.; Smolko, E. E.; Suarez, C. E.

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All this grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA).

  4. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    International Nuclear Information System (INIS)

    Docters, E.H.; Smolko, E.E.

    1990-01-01

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All these grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA). (author)

  5. Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies

    Energy Technology Data Exchange (ETDEWEB)

    Docters, E H; Smolko, E E [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Direccion de Radioisotopos y Radiaciones; Suarez, C E [Instituto Nacional de Tecnologia Agropecuaria, Castelar (Argentina)

    1990-01-01

    The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All these grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA). (author).

  6. Comparison of a newly developed automated and quantitative hepatitis C virus (HCV) core antigen test with the HCV RNA assay for clinical usefulness in confirming anti-HCV results.

    Science.gov (United States)

    Kesli, Recep; Polat, Hakki; Terzi, Yuksel; Kurtoglu, Muhammet Guzel; Uyar, Yavuz

    2011-12-01

    Hepatitis C virus (HCV) is a global health care problem. Diagnosis of HCV infection is mainly based on the detection of anti-HCV antibodies as a screening test with serum samples. Recombinant immunoblot assays are used as supplemental tests and for the final detection and quantification of HCV RNA in confirmatory tests. In this study, we aimed to compare the HCV core antigen test with the HCV RNA assay for confirming anti-HCV results to determine whether the HCV core antigen test may be used as an alternative confirmatory test to the HCV RNA test and to assess the diagnostic values of the total HCV core antigen test by determining the diagnostic specificity and sensitivity rates compared with the HCV RNA test. Sera from a total of 212 treatment-naive patients were analyzed for anti-HCV and HCV core antigen both with the Abbott Architect test and with the molecular HCV RNA assay consisting of a reverse transcription-PCR method as a confirmatory test. The diagnostic sensitivity, specificity, and positive and negative predictive values of the HCV core antigen assay compared to the HCV RNA test were 96.3%, 100%, 100%, and 89.7%, respectively. The levels of HCV core antigen showed a good correlation with those from the HCV RNA quantification (r = 0.907). In conclusion, the Architect HCV antigen assay is highly specific, sensitive, reliable, easy to perform, reproducible, cost-effective, and applicable as a screening, supplemental, and preconfirmatory test for anti-HCV assays used in laboratory procedures for the diagnosis of hepatitis C virus infection.

  7. Detection of Avian Antigen-Specific T Cells Induced by Viral Vaccines

    DEFF Research Database (Denmark)

    Dalgaard, Tina Sørensen; Norup, Liselotte Rothmann; Juul-Madsen, Helle Risdahl

    2016-01-01

    Live attenuated viral vaccines are widely used in commercial poultry production, but the development of new effective inactivated/subunit vaccines is needed. Studies of avian antigen-specific T cells are primarily based on analyses ex vivo after activating the cells with recall antigen. There is ......Live attenuated viral vaccines are widely used in commercial poultry production, but the development of new effective inactivated/subunit vaccines is needed. Studies of avian antigen-specific T cells are primarily based on analyses ex vivo after activating the cells with recall antigen...

  8. Identification of antigenic Sarcoptes scabiei proteins for use in a diagnostic test and of non-antigenic proteins that may be immunomodulatory

    Science.gov (United States)

    Morgan, Marjorie S.; Rider, S. Dean; Arlian, Larry G.

    2017-01-01

    Background Scabies, caused by the mite, Sarcoptes scabiei, infects millions of humans, and many wild and domestic mammals. Scabies mites burrow in the lower stratum corneum of the epidermis of the skin and are the source of substances that are antigenic or modulate aspects of the protective response of the host. Ordinary scabies is a difficult disease to diagnose. Objective The goal of this project was to identify S. scabiei proteins that may be candidate antigens for use in a diagnostic test or may be used by the mite to modulate the host’s protective response. Methods An aqueous extract of S. scabiei was separated by 2-dimensional electrophoresis and proteins were identified by mass spectrometry. A parallel immunoblot was probed with serum from patients with ordinary scabies to identify IgM and/or IgG-binding antigens. The genes coding for 23 selected proteins were cloned into E. coli and the expressed recombinant proteins were screened with serum from patients with confirmed ordinary scabies. Results We identified 50 different proteins produced by S. scabiei, 34 of which were not previously identified, and determined that 66% were recognized by patient IgM and/or IgG. Fourteen proteins were screened for use in a diagnostic test but none possessed enough sensitivity and specificity to be useful. Six of the 9 proteins selected for the possibility that they may be immunomodulatory were not recognized by antibodies in patient serum. Conclusions Thirty-three proteins that bound IgM and/or IgG from the serum of patients with ordinary scabies were identified. None of the 14 tested were useful for inclusion in a diagnostic test. The identities of 16 proteins that are not recognized as antigens by infected patients were also determined. These could be among the molecules that are responsible for this mite’s ability to modulate its host’s innate and adaptive immune responses. PMID:28604804

  9. Identification of antigenic Sarcoptes scabiei proteins for use in a diagnostic test and of non-antigenic proteins that may be immunomodulatory.

    Directory of Open Access Journals (Sweden)

    Marjorie S Morgan

    2017-06-01

    Full Text Available Scabies, caused by the mite, Sarcoptes scabiei, infects millions of humans, and many wild and domestic mammals. Scabies mites burrow in the lower stratum corneum of the epidermis of the skin and are the source of substances that are antigenic or modulate aspects of the protective response of the host. Ordinary scabies is a difficult disease to diagnose.The goal of this project was to identify S. scabiei proteins that may be candidate antigens for use in a diagnostic test or may be used by the mite to modulate the host's protective response.An aqueous extract of S. scabiei was separated by 2-dimensional electrophoresis and proteins were identified by mass spectrometry. A parallel immunoblot was probed with serum from patients with ordinary scabies to identify IgM and/or IgG-binding antigens. The genes coding for 23 selected proteins were cloned into E. coli and the expressed recombinant proteins were screened with serum from patients with confirmed ordinary scabies.We identified 50 different proteins produced by S. scabiei, 34 of which were not previously identified, and determined that 66% were recognized by patient IgM and/or IgG. Fourteen proteins were screened for use in a diagnostic test but none possessed enough sensitivity and specificity to be useful. Six of the 9 proteins selected for the possibility that they may be immunomodulatory were not recognized by antibodies in patient serum.Thirty-three proteins that bound IgM and/or IgG from the serum of patients with ordinary scabies were identified. None of the 14 tested were useful for inclusion in a diagnostic test. The identities of 16 proteins that are not recognized as antigens by infected patients were also determined. These could be among the molecules that are responsible for this mite's ability to modulate its host's innate and adaptive immune responses.

  10. Study of bacterial meningitis in children below 5 years with comparative evaluation of gram staining, culture and bacterial antigen detection.

    Science.gov (United States)

    Yadhav Ml, Kala

    2014-04-01

    Bacterial meningitis is one of the most serious infections seen in infants and children, which is associated with acute complications and chronic morbidity. Infections of Central Nervous System (CNS) still dominate the scene of childhood neurological disorders in most of the developing tropical countries. To isolate, identify and determine the antibiotic susceptibility patterns of pathogens associated with bacterial meningitis. We also aimed to comparatively evaluate of Gram staining, culture and bacterial antigen detection in cerebrospinal fluid samples. Present comparative study included 100 CSF samples of children below the age of 5 years, who were clinically suspected meningitis cases. The samples were subjected to Gram staining, culture and Latex agglutination test (LAT). The organisms isolated in the study were characterized and antibiotic susceptibility test was done according to standard guidelines. It was done by using Gaussian test. Of the 100 cases, 24 were diagnosed as Acute bacterial meningitis (ABM) cases by. Gram staining, culture and latex agglutination test. 21 (87.5%) cases were culture positive, with 2 cases being positive for polymicrobial isolates. Gram staining was positive in 17 (70.53%) cases and LAT was positive in 18 (33.33%) cases. Streptococcus pneumoniae was the predominant organism which was isolated and it was sensitive to antibiotics. In the present study, male to female ratio was 1.27:1, which showed a male preponderance. With the combination of Gram staining, culture, and LAT, 100% sensitivity and specificity can be achieved (p Gram staining and LAT can detect 85% of cases of ABM. Bacterial meningitis is a medical emergency and making an early diagnosis and providing treatment early are life saving and they reduce chronic morbidity.

  11. A Lateral Flow Rapid Test for Human Toxocariasis Developed Using Three Toxocara canis Recombinant Antigens.

    Science.gov (United States)

    Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah

    2018-01-01

    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.

  12. Immunohistochemical detection of PGL-1, LAM, 30 kD and 65 kD antigens in leprosy infected paraffin preserved skin and nerve sections

    NARCIS (Netherlands)

    van den Bos, I. C.; Khanolkar-Young, S.; Das, P. K.; Lockwood, D. N.

    1999-01-01

    A panel of lipid, carbohydrate and protein antibodies were optimized for use in detecting M. leprae antigens in paraffin embedded material. Skin and nerve biopsies from 13 patients across the leprosy spectrum were studied. All antibodies detected antigen in tissues with a BI > 1. Phenolic-glycolipid

  13. Fabrication of graphene/gold-modified screen-printed electrode for detection of carcinoembryonic antigen

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.F. [Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, UPM Serdang, 43400 Selangor (Malaysia); Lim, H.N., E-mail: janetlimhn@gmail.com [Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, UPM Serdang, 43400 Selangor (Malaysia); Shams, N. [Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, UPM Serdang, 43400 Selangor (Malaysia); Jayabal, S.; Pandikumar, A.; Huang, N.M. [Low Dimensional Materials Research Centre (LDMRC), Physics Department, Faculty of Science, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2016-01-01

    Immunosensors based on gold nanoparticles and reduced graphene oxide (AuNPs/rGO)-modified screen-printed electrodes (SPEs) were successfully synthesized using an electrochemical deposition method. The modified SPEs were characterized using a field emission scanning electron microscope (FESEM) and Raman spectroscopy to analyze the morphology and composition of AuNPs and rGO. Both the FESEM and Raman spectroscopy revealed that the AuNPs were successfully anchored on the thin film of rGO deposited on the surface of the SPEs. Characterization with a ferri–ferrocyanide couple [Fe(CN){sub 6}{sup 3−/4−}] showed that the electron transfer kinetic between the analyte and electrode was enhanced after the modification with the AuNPs/rGO composite on the electrode surface, in addition to increasing the effective surface area of the electrode. The modified SPE was immobilized with a sandwich type immunosensor to mimic the ELISA (enzyme-linked immunosorbent assay) immunoassay. The modified SPE that was fortified with the sandwich type immunosensor exhibited double electrochemical responses in the detection of carcinoembryonic antigen (CEA), with linear ranges of 0.5–50 ng/mL and 250–2000 ng/mL and limits of detection of 0.28 ng/mL and 181.5 ng/mL, respectively. - Highlights: • An AuNP/rGO-modified SPE is prepared via an in-situ electrodeposition method. • It is introduced in a sandwich-type immunoassay for the detection of CEA. • The LODs for CEA are 0.28 ng/mL for 0.5–25 ng/mL, and 181.5 ng/mL for 250–2000 ng/mL.

  14. Transrectal ultrasound in detecting prostate cancer compared with serum total prostate-specific antigen levels

    International Nuclear Information System (INIS)

    Tamsel, S.; Killi, R.; Demirpolat, G.; Hekimgil, M.; Soydan, S.; Altay, B.

    2008-01-01

    We carried out a retrospective study to review the efficiency of grey-scale transrectal ultrasonography (TRUS) in detecting prostate cancer compared with the data in recent published work, including alternative imaging methods of the prostate gland. Our study group consisted of 830 patients who underwent TRUS-guided biopsy of the prostate between May 2000 and June 2004. The relation between abnormal TRUS findings and serum total prostate-specific antigen (tPSA) levels was evaluated in patients with prostate cancer who were divided into three different groups according to serum tPSA levels. Group I included patients with tPSA levels of 4-9.9 ng/mL, group II included tPSA levels of 10-19.9 ng/mL and group III included patients with tPSA levels of 20 ng/mL or more. In general, TRUS detected 185 (64%) of 291 cancers with a specificity of 89%, a PPV of 76% and an accuracy of 80%. TRUS findings enabled the correct identification of 22 (56%) of the 39 cancers in group I, 28 (30%) of the 93 cancers in group II and 135 (85%) of the 159 cancers in group III. In conclusion, TRUS alone has a limited potential to identify prostate cancer, especially in patients with tPSA levels lower than 20 ng/mL. Therefore, increased numbers of systematically placed biopsy cores must be taken or alternative imaging methods are required to direct TRUS-guided biopsy for improving prostate cancer detection.

  15. Detection of intracellular canine distemper virus antigen in mink inoculated with an attenuated or a virulent strain of canine distemper virus.

    Science.gov (United States)

    Blixenkrone-Møller, M

    1989-09-01

    Using an indirect immunofluorescence technique, the distribution of viral antigen in various tissues and blood mononuclear leukocytes was studied in wild mink, either vaccinated with an attenuated vaccine strain of canine distemper virus (CDV) or experimentally inoculated with the virulent Snyder-Hill strain of CDV. Viral antigen was detected in cells of the lymphoid system 6 to 12 days after vaccination. From 2 to 3 days after inoculation with the virulent strain, CDV antigen was demonstrated in cells of the lymphoid system and, during the incubation period, the antigen had spread to the epithelia and brain at days 6 and 12, respectively. In clinical cases of acute fatal canine distemper, the viral antigen was detected in a wide variety of tissues, including the cells of the lymphoid system, epithelial cells of skin, mucous membranes, lung, kidney, and cells of the CNS. The diagnostic importance of CDV antigen detection is discussed on the basis of these findings.

  16. Standardization of micro-enzyme-linked immunosorbent assay (ELISA) and Western blot for detection of Trypanosoma cruzi antibodies using extracts from Mexican strains as antigens.

    Science.gov (United States)

    Sánchez, B; Monteón, V; Reyes, P A; Espinoza, B

    2001-01-01

    This report describes two assays for the detection of anti-Trypanosoma cruzi antibodies using Mexican strains of the parasite and the concordance with two assays previously evaluated at the Instituto Nacional de Cardiología Ignacio Chávez in Mexico City. Micro-enzyme-linked immunosorbent assay (ELISA) and Western blot were used for the detection of T. cruzi antibodies with a total extract of epimastigote from Ninoa and Queretaro, which are Mexican strains of T. cruzi. To standardize these methods, a total of 246 serum samples was used. In addition, sera from six confirmed Mexican chronic individuals in the asymptomatic phase were also used for comparison with the Argentinean antigen. ELISA was 100% specific in that no false positive results were found with sera of both healthy individuals and non-Chagasic cardiopaths. Sera from individuals infected with Leishmania sp. showed approximately 16% of cross-reaction with ELISA. The test showed a positive predictive value of 90% and a negative predictive value of 100%. Western blot was also a highly sensitive test for detecting chronic Chagasic symptomatic patients from Mexico because no false negative results were obtained. Furthermore, it was possible to use Western blot to detect seven immunodominant antigens of approximately 30, 32, 40, 42, 65, 70, and 83 kDa. Concordance with two previous standardized tests at the Instituto Nacional de Cardiología showed a Kappa index of 0.96, indicating high concordance between the results obtained at these two laboratories. Finally, ELISA using Ninoa antigen extract was more sensitive than ELISA with an Argentinean extract, which failed to detect individuals in the chronic asymptomatic phase (undetermined phase) of infection. This study indicates that ELISA and Western blot using Ninoa and/or Queretaro extracts of T. cruzi as antigens are useful tools in the detection of individuals who have been exposed to T. cruzi both in the undetermined/asymptomatic and symptomatic phases

  17. Quantitative detection of the tumor-associated antigen large external antigen in colorectal cancer tissues and cells using quantum dot probe

    Directory of Open Access Journals (Sweden)

    Wang S

    2016-01-01

    Full Text Available Shuo Wang, Wanming Li, Dezheng Yuan, Jindan Song, Jin Fang Department of Cell Biology, Key Laboratory of Cell Biology, Ministry of Public Health, and Key Laboratory of Medical Cell Biology, Ministry of Education, China Medical University, Shenyang, People’s Republic of China Abstract: The large external antigen (LEA is a cell surface glycoprotein that has been proven to be highly expressed in colorectal cancer (CRC as a tumor-associated antigen. To evaluate and validate the relationship between LEA expression and clinical characteristics of CRC with high efficiency, LEA expression levels were detected in 85 tissue blocks from CRC patients by quantum dot-based immunohistochemistry (QD-IHC combined with imaging quantitative analysis using quantum dots with a 605 nm emission wavelength (QD605 conjugated to an ND-1 monoclonal antibody against LEA as a probe. Conventional IHC was performed in parallel for comparison. Both QD-IHC and conventional IHC showed that LEA was specifically expressed in CRC, but not in non-CRC tissues, and high LEA expression was significantly associated with a more advanced T-stage (P<0.05, indicating that LEA is likely to serve as a CRC prognostic marker. Compared with conventional IHC, receiver operating characteristic analysis revealed that QD-IHC possessed higher sensitivity, resulting in an increased positive detection rate of CRC, from 70.1% to 89.6%. In addition, a simpler operation, objective analysis of results, and excellent repeatability make QD-IHC an attractive alternative to conventional IHC in clinical practice. Furthermore, to explore whether the QD probes can be utilized to quantitatively detect living cells or single cells, quantum dot-based immunocytochemistry (QD-ICC combined with imaging quantitative analysis was developed to evaluate LEA expression in several CRC cell lines. It was demonstrated that QD-ICC could also predict the correlation between LEA expression and the T-stage characteristics of

  18. Helicobacter pylori stool antigen test (HpSA) for the diagnosis of gastric infection

    International Nuclear Information System (INIS)

    Faruqui, A.N.; Majid, U.; Ahmed, L.; Khalil, M.; Hussan, M.U.

    2007-01-01

    To determine the accuracy of Helicobacter pylori Stool Antigen test (HpSA), compared with endoscopic histopathology for the diagnosis of gastric Helicobecter pylori infection. A total of 50 patients underwent endoscopy for gastric antral mucosal tissue biopsy for histopathology of H.pylori and advised for HpSA. Patient's information including age, gender, past history, presenting signs and symptoms, results of HpSA and histopathology were recorded. Sensitivity analysis was performed to calculate sensitivity, specificity, and predictive values of HpSA. Among 50 patients, 48% males and 52% females (M: F 1: 1.08), a total of 27 (54%) were true positive while 20 (40%) were true negative. Two patients were false negative and only one was false positive. Sensitivity of HpSA was, therefore, 93.1%, specificity 95% and positive and negative predictive values were 96.42% and 90.9% respectively. Helicobacter pylori stool antigen was an accurate and reliable test for the diagnosis of gastric H. pylori infection. (author)

  19. Inclusion bodies of recombinant Epstein-Barr virus capsid antigen p18 as potential immobilized antigens in enzyme immunoassays for detection of nasopharyngeal carcinoma.

    Science.gov (United States)

    Lim, Chun Shen; Goh, Siang Ling; Kariapper, Leena; Krishnan, Gopala; Lim, Yat-Yuen; Ng, Ching Ching

    2015-08-25

    Development of indirect enzyme-linked immunosorbent assays (ELISAs) often utilizes synthetic peptides or recombinant proteins from Escherichia coli as immobilized antigens. Because inclusion bodies (IBs) formed during recombinant protein expression in E. coli are commonly thought as misfolded aggregates, only refolded proteins from IBs are used to develop new or in-house diagnostic assays. However, the promising utilities of IBs as nanomaterials and immobilized enzymes as shown in recent studies have led us to explore the potential use of IBs of recombinant Epstein-Barr virus viral capsid antigen p18 (VCA p18) as immobilized antigens in ELISAs for serologic detection of nasopharyngeal carcinoma (NPC). Thioredoxin fusion VCA p18 (VCA-Trx) and IBs of VCA p18 without fusion tags (VCA-IBs) were purified from E. coli. The diagnostic performances of IgG/VCA-IBs, IgG/VCA-Denat-IBs (using VCA-IBs coated in 8mol/l urea), IgG/VCA-Trx, and IgG/VCA-Peptide assays were compared by screening 100 NPC case-control pairs. The IgG/VCA-Denat-IBs assay showed the best area under the receiver operating characteristic curve (AUC: 0.802; p<0.05), while the AUCs for the IgG/VCA-IBs, IgG/VCA-Trx, and IgG/VCA-Peptide assays were comparable (AUC: 0.740, 0.727, and 0.741, respectively). We improved the diagnostic performance of the ELISA significantly using IBs of recombinant VCA p18. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Next-generation detection of antigen-responsive T cells using DNA barcode-labeled peptidemajor histocompatibility complex I multimers

    DEFF Research Database (Denmark)

    Bentzen, Amalie Kai; Marquard, Andrea Marion; Lyngaa, Rikke Birgitte

    2016-01-01

    diversity of T cell recognition in humans. Consequently it has been impossible to comprehensively analyze T cell responsiveness in cancer, infectious and autoimmune diseases. We present and validate a novel technology that enables parallel detection of numerous different peptide-MHC responsive T cells...... with combinatorial encoding of fluorescent-labeled MHC multimers. Finally, we have demonstrated that this technology can be applied for multiplex T cell detection both in limited biological samples, such as uncultured tumor material, and for simultaneous assessment of target recognition and functional capability...... of T cells. This technology enables true high-throughput detection of antigen-responsive T cells and will advance our understanding of immune recognition from model antigens to genomewide immune assessments on a personalized basis....

  1. Noninvasive Test Detects Cardiovascular Disease

    Science.gov (United States)

    2007-01-01

    At NASA's Jet Propulsion Laboratory (JPL), NASA-developed Video Imaging Communication and Retrieval (VICAR) software laid the groundwork for analyzing images of all kinds. A project seeking to use imaging technology for health care diagnosis began when the imaging team considered using the VICAR software to analyze X-ray images of soft tissue. With marginal success using X-rays, the team applied the same methodology to ultrasound imagery, which was already digitally formatted. The new approach proved successful for assessing amounts of plaque build-up and arterial wall thickness, direct predictors of heart disease, and the result was a noninvasive diagnostic system with the ability to accurately predict heart health. Medical Technologies International Inc. (MTI) further developed and then submitted the technology to a vigorous review process at the FDA, which cleared the software for public use. The software, patented under the name Prowin, is being used in MTI's patented ArterioVision, a carotid intima-media thickness (CIMT) test that uses ultrasound image-capturing and analysis software to noninvasively identify the risk for the major cause of heart attack and strokes: atherosclerosis. ArterioVision provides a direct measurement of atherosclerosis by safely and painlessly measuring the thickness of the first two layers of the carotid artery wall using an ultrasound procedure and advanced image-analysis software. The technology is now in use in all 50 states and in many countries throughout the world.

  2. Evaluation of Selected Borrelia burgdorferi lp54 Plasmid-Encoded Gene Products Expressed during Mammalian Infection as Antigens To Improve Serodiagnostic Testing for Early Lyme Disease

    Science.gov (United States)

    Weiner, Zachary P.; Crew, Rebecca M.; Brandt, Kevin S.; Ullmann, Amy J.; Schriefer, Martin E.; Molins, Claudia R.

    2015-01-01

    Laboratory testing for the diagnosis of Lyme disease is performed primarily by serologic assays and is accurate for detection beyond the acute stage of the infection. Serodiagnostic assays to detect the early stages of infection, however, are limited in their sensitivity, and improvement is warranted. We analyzed a series of Borrelia burgdorferi proteins known to be induced within feeding ticks and/or during mammalian infection for their utility as serodiagnostic markers against a comprehensive panel of Lyme disease patient serum samples. The antigens were assayed for IgM and IgG reactivity in line immunoblots and separately by enzyme-linked immunosorbent assay (ELISA), with a focus on reactivity against early Lyme disease with erythema migrans (EM), early disseminated Lyme neuroborreliosis, and early Lyme carditis patient serum samples. By IgM immunoblotting, we found that recombinant proteins BBA65, BBA70, and BBA73 reacted with early Lyme EM samples at levels comparable to those of the OspC antigen used in the current IgM blotting criteria. Additionally, these proteins reacted with serum samples from patients with early neuroborreliosis and early carditis, suggesting value in detecting early stages of this disease progression. We also found serological reactivity against recombinant proteins BBA69 and BBA73 with early-Lyme-disease samples using IgG immunoblotting and ELISA. Significantly, some samples that had been scored negative by the Centers for Disease Control and Prevention-recommended 2-tiered testing algorithm demonstrated positive reactivity to one or more of the antigens by IgM/IgG immunoblot and ELISA. These results suggest that incorporating additional in vivo-expressed antigens into the current IgM/IgG immunoblotting tier in a recombinant protein platform assay may improve the performance of early-Lyme-disease serologic testing. PMID:26376927

  3. Evaluation of Selected Borrelia burgdorferi lp54 Plasmid-Encoded Gene Products Expressed during Mammalian Infection as Antigens To Improve Serodiagnostic Testing for Early Lyme Disease.

    Science.gov (United States)

    Weiner, Zachary P; Crew, Rebecca M; Brandt, Kevin S; Ullmann, Amy J; Schriefer, Martin E; Molins, Claudia R; Gilmore, Robert D

    2015-11-01

    Laboratory testing for the diagnosis of Lyme disease is performed primarily by serologic assays and is accurate for detection beyond the acute stage of the infection. Serodiagnostic assays to detect the early stages of infection, however, are limited in their sensitivity, and improvement is warranted. We analyzed a series of Borrelia burgdorferi proteins known to be induced within feeding ticks and/or during mammalian infection for their utility as serodiagnostic markers against a comprehensive panel of Lyme disease patient serum samples. The antigens were assayed for IgM and IgG reactivity in line immunoblots and separately by enzyme-linked immunosorbent assay (ELISA), with a focus on reactivity against early Lyme disease with erythema migrans (EM), early disseminated Lyme neuroborreliosis, and early Lyme carditis patient serum samples. By IgM immunoblotting, we found that recombinant proteins BBA65, BBA70, and BBA73 reacted with early Lyme EM samples at levels comparable to those of the OspC antigen used in the current IgM blotting criteria. Additionally, these proteins reacted with serum samples from patients with early neuroborreliosis and early carditis, suggesting value in detecting early stages of this disease progression. We also found serological reactivity against recombinant proteins BBA69 and BBA73 with early-Lyme-disease samples using IgG immunoblotting and ELISA. Significantly, some samples that had been scored negative by the Centers for Disease Control and Prevention-recommended 2-tiered testing algorithm demonstrated positive reactivity to one or more of the antigens by IgM/IgG immunoblot and ELISA. These results suggest that incorporating additional in vivo-expressed antigens into the current IgM/IgG immunoblotting tier in a recombinant protein platform assay may improve the performance of early-Lyme-disease serologic testing. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  4. Detecting Test Tampering Using Item Response Theory

    Science.gov (United States)

    Wollack, James A.; Cohen, Allan S.; Eckerly, Carol A.

    2015-01-01

    Test tampering, especially on tests for educational accountability, is an unfortunate reality, necessitating that the state (or its testing vendor) perform data forensic analyses, such as erasure analyses, to look for signs of possible malfeasance. Few statistical approaches exist for detecting fraudulent erasures, and those that do largely do not…

  5. Long-lived immunity to canine core vaccine antigens in UK dogs as assessed by an in-practice test kit.

    Science.gov (United States)

    Killey, R; Mynors, C; Pearce, R; Nell, A; Prentis, A; Day, M J

    2018-01-01

    To determine the utility of an in-practice test kit to detect protective serum antibody against canine distemper virus, canine adenovirus and canine parvovirus type 2 in a sample of the UK dog population. Serum samples from 486 dogs, last vaccinated between less than 1 month and 124 months previously, were tested with the VacciCheck™ test kit for protective antibodies against distemper, adenovirus and parvovirus type 2. A high proportion of the dogs tested (93·6%) had protective antibody against all three of the core vaccine antigens: 95·7% of the dogs were seropositive against canine distemper virus, 97·3% against canine adenovirus and 98·5% against canine parvovirus type 2. The small number of dogs that were seronegative for one or more of the antigens (n = 31) may have had waning of previous serum antibody or may have been rare genetic non-responders to that specific antigen. UK veterinarians can be reassured that triennial revaccination of adult dogs with core vaccines provides long-lived protective immunity. In-practice serological test kits are a valuable tool for informing decision-making about canine core revaccination. © 2017 British Small Animal Veterinary Association.

  6. The future (r)evolution of preimplantation genetic diagnosis/human leukocyte antigen testing: ethical reflections.

    Science.gov (United States)

    de Wert, Guido; Liebaers, Inge; Van de Velde, Hilde

    2007-09-01

    There has been increasing support for combining preimplantation genetic diagnosis (PGD) for specific diseases with a test for human leukocyte antigens (HLA) because the generation of HLA-matched umbilical cord blood cells may save the life of a diseased sibling. To date, this procedure has taken place in the context of conceiving another child--PGD/HLA testing type 1. However, it may well become possible to perform PGD/HLA testing outside this context, that is, to select matched embryos from which embryonic stem cells could be derived and used in cell therapy--PGD/HLA testing type 2. A proactive ethical analysis is needed and is presented in this article. Although PGD/HLA testing type 1 can be morally justified, the risks, pitfalls, and practical limitations of this procedure make it necessary to develop alternative strategies. PGD/HLA testing type 2 may provide an alternative strategy. From an ethical point of view, the controversial issue is that this procedure creates embryos purely for instrumental use. However, given the dominant view that the preimplantation embryo has only limited moral value, this alternative may be as morally justified as PGD/HLA testing type 1.

  7. Two types of nanoparticle-based bio-barcode amplification assays to detect HIV-1 p24 antigen

    Directory of Open Access Journals (Sweden)

    Dong Huahuang

    2012-08-01

    Full Text Available Abstract Background HIV-1 p24 antigen is a major viral component of human immunodeficiency virus type 1 (HIV-1 which can be used to identify persons in the early stage of infection and transmission of HIV-1 from infected mothers to infants. The detection of p24 is usually accomplished by using an enzyme-linked immunosorbent assay (ELISA with low detection sensitivity. Here we report the use of two bio-barcode amplification (BCA assays combined with polymerase chain reaction (PCR and gel electrophoresis to quantify HIV-1 p24 antigen. Method A pair of anti-p24 monoclonal antibodies (mAbs were used in BCA assays to capture HIV-1 p24 antigen in a sandwich format and allowed for the quantitative measurement of captured p24 using PCR and gel electrophoresis. The first 1 G12 mAb was coated on microplate wells or magnetic microparticles (MMPs to capture free p24 antigens. Captured p24 in turn captured 1D4 mAb coated gold nanoparticle probes (GNPs containing double-stranded DNA oligonucleotides. One strand of the oligonucleotides was covalently immobilized whereas the unbound complimentary bio-barcode DNA strand could be released upon heating. The released bio-barcode DNA was amplified by PCR, electrophoresed in agarose gel and quantified. Results The in-house ELISA assay was found to quantify p24 antigen with a limit of detection (LOD of 1,000 pg/ml and a linear range between 3,000 and 100,000 pg/ml. In contrast, the BCA-based microplate method yielded an LOD of 1 pg/ml and a linear detection range from 1 to 10,000 pg/ml. The BCA-based MMP method yielded an LOD of 0.1 pg/ml and a linear detection range from 0.1 to 1,000 pg/ml. Conclusions When combined with PCR and simple gel electrophoresis, BCA-based microplate and MMPs assays can be used to quantify HIV-1 p24 antigen. These methods are 3–4 orders of magnitude more sensitive than our in-house ELISA-based assay and may provide a useful approach to detect p24 in patients newly infected

  8. A novel colloidal gold labeled antigen for the detection of Deoxynivalenol using an immunochromatographic assay method

    Science.gov (United States)

    Jin, Yu; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen

    2017-11-01

    In this paper, an immunochromatographic assay card was developed for the detection of DON in feed and cereals using a novel colloidal gold labeling method. For the colloidal gold immunochromatographic rapid detection (GICD) card, a monoclonal antibody DON-mAb and a goat anti-chicken IgY were drawn on NC membrane as the test line (T line) and the control line (C line) respectively. A gold labeled DON-CBSA conjugate and a gold labeled chicken IgY were sprayed onto the conjugate pad. The GICD card has cut-off levels of 50ng/mL for DON, which is invulnerable to matrix interference, and applicable to a wide range of samples. The GICD detecting results of feed and grain samples were compared with the results of ELISA testing, which showed good consistency.

  9. The detection of K88, K99 fimbrial antigen and enterotoxin genes of Escherichia coli isolated from piglets and calves with diarrhoea in Indonesia

    Directory of Open Access Journals (Sweden)

    Supar

    1996-03-01

    Full Text Available Enterotoxigenic Escherichia coli (ETEC strains cause diarrhoeal disease in piglets and calves in Indonesia. These strains possess two virulence factors namely attachment and enterotoxin antigens . These factors could be detected phenotypically and genetically. Haemolytic Escherichia coli (E coli isolates possessing K88 fimbrial antigen associated with 0-group 108 and 149. They were positive for K88 gene and demonstrated their ability to produce heat labile enterotoxin (LT and genetically were all positive for LT gene . Seventeen isolates ofE coli K88 which associated with 0-group 149 were positive forSTb gene, other O-serotypes were negative . Ten isolates of Ecoli K88 which associated with 0-group 108 possessed K88, K99, LT and STa genes, but negative for STb gene . However, phenotypically the K99 antigen and STa toxin were not expressed under laboratory conditions, the reason was not well understood . E. coli K99 strains isolated from calves wit h diarrhoea were all associated with 0-group 9 and produced STa toxin when tested by suckling mousse bioassay. The E. coli K99 calf isolates were all hybridized with K99 and STa gene only . It is likely that K99 gene is associated with STa gene . The DNA hybridization technique is more convenience to be used for confirmation diagnosis of colibacillosis, however, not all veterinary laboratories could perform these tests .

  10. [Detection of fps tumor antigen with mono-specific anti-fps serum in tumors induced by acute transforming ALV].

    Science.gov (United States)

    Wang, Yixin; Chen, Hao; Zhao, Peng; Li, Jianliang; Cui, Zhizhong

    2013-03-04

    To prepare anti-fps mono-specific serum, and detect the fps antigen in tumors induced by acute transforming avian leukosis/sarcoma virus containing v-fps oncogene. Two part of v-fps gene was amplified by RT-PCR using the Fu-J viral RNA as the template. Mono-specific serum was prepared by immuning Kunming white mouse with both two recombinant infusion proteins expressed by the prokaryotic expression system. Indirect immunofluorescent assay was used to detect fps antigen in tumor tissue suspension cells and CEF infected by sarcoma supernatant. Immunohistochemical method was used to detect fps antigen in tumor tissue. The mouse mono-specific serum was specific as it had no cross reaction with classical ALV-J strains. The result reveals that the tumor tissue suspension cells, the CEF infected by sarcoma supernatant, and the slice immunohistochemistry of the sarcoma showed positive results. The anti-fps mono-specific serum was prepared, and the detection method was established, which laid the foundation for the study of viral biological characteristics and mechanism of tumourgenesis of acute transforming avian leukosis/sarcoma virus containing v-fps oncogene.

  11. Laser Obstacle Detection System Flight Testing

    National Research Council Canada - National Science Library

    Davis, Timothy

    2003-01-01

    ...). The Aviation Applied Technology Directorate (AATD) was contracted to mount the HELLAS sensor on the nose of a UH-60L Blackhawk helicopter and to conduct flight tests to evaluate the HELLAS obstacle detection sensor...

  12. Recent Patterns in Shared Decision Making for Prostate-Specific Antigen Testing in the United States.

    Science.gov (United States)

    Fedewa, Stacey A; Gansler, Ted; Smith, Robert; Sauer, Ann Goding; Wender, Richard; Brawley, Otis W; Jemal, Ahmedin

    2018-03-01

    Previous studies report infrequent use of shared decision making for prostate-specific antigen (PSA) testing. It is unknown whether this pattern has changed recently considering increased emphasis on shared decision making in prostate cancer screening recommendations. Thus, the objective of this study is to examine recent changes in shared decision making. We conducted a retrospective cross-sectional study among men aged 50 years and older in the United States using 2010 and 2015 National Health Interview Survey (NHIS) data (n = 9,598). Changes in receipt of shared decision making were expressed as adjusted prevalence ratios (aPR) and 95% confidence intervals (CI). Analyses were stratified on PSA testing (recent [in the past year] or no testing). Elements of shared decision making assessed included the patient being informed about the advantages only, advantages and disadvantages, and full shared decision making (advantages, disadvantages, and uncertainties). Among men with recent PSA testing, 58.5% and 62.6% reported having received ≥1 element of shared decision making in 2010 and 2015, respectively ( P = .054, aPR = 1.04; 95% CI, 0.98-1.11). Between 2010 and 2015, being told only about the advantages of PSA testing significantly declined (aPR = 0.82; 95% CI, 0.71-0.96) and full shared decision making prevalence significantly increased (aPR = 1.51; 95% CI, 1.28-1.79) in recently tested men. Among men without prior PSA testing, 10% reported ≥1 element of shared decision making, which did not change with time. Between 2010 and 2015, there was no increase in shared decision making among men with recent PSA testing though there was a shift away from only being told about the advantages of PSA testing towards full shared decision making. Many men receiving PSA testing did not receive shared decision making. © 2018 Annals of Family Medicine, Inc.

  13. Comparison of antigen detection and quantitative PCR in the detection of chlamydial infection in koalas (Phascolarctos cinereus).

    Science.gov (United States)

    Hanger, Jon; Loader, Joanne; Wan, Charles; Beagley, Kenneth W; Timms, Peter; Polkinghorne, Adam

    2013-03-01

    The gold standard method for detecting chlamydial infection in domestic and wild animals is PCR, but the technique is not suited to testing animals in the field when a rapid diagnosis is frequently required. The objective of this study was to compare the results of a commercially available enzyme immunoassay test for Chlamydia against a quantitative Chlamydia pecorum-specific PCR performed on swabs collected from the conjunctival sac, nasal cavity and urogenital sinuses of naturally infected koalas (Phascolarctos cinereus). The level of agreement for positive results between the two assays was low (43.2%). The immunoassay detection cut-off was determined as approximately 400 C. pecorum copies, indicating that the test was sufficiently sensitive to be used for the rapid diagnosis of active chlamydial infections. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Comparison of nine antigen detection kits for diagnosis of urogenital infections due to Chlamydia psittaci in koalas.

    OpenAIRE

    Wood, M M; Timms, P

    1992-01-01

    Chlamydia psittaci is the major cause of infectious disease in the koala (Phascolarctos cinereus). It causes four disease syndromes in the koala, namely, conjunctivitis, rhinitis, cystitis, and infertility (females only). Diagnosis of chlamydial infections in koalas relies primarily on isolation of the organism in cell culture. Serology has generally not been useful, and little use has previously been made of the commercially available antigen detection kits. We examined the sensitivity, spec...

  15. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    OpenAIRE

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of th...

  16. Supporting informed decision making for prostate specific antigen (PSA) testing on the web: an online randomized controlled trial.

    NARCIS (Netherlands)

    Evans, R.; Joseph-Williams, N.; Edwards, A.; Newcombe, R.G.; Wright, P.; Kinnersley, P.; Griffiths, J.; Jones, M.; Williams, J.; Grol, R.P.T.M.; Elwyn, G.

    2010-01-01

    BACKGROUND: Men considering the prostate specific antigen (PSA) test for prostate cancer, an increasingly common male cancer, are encouraged to make informed decisions, as the test is limited in its accuracy and the natural history of the condition is poorly understood. The Web-based PSA decision

  17. Multisignal detecting system of pile integrity testing

    Science.gov (United States)

    Liu, Zuting; Luo, Ying; Yu, Shihai

    2002-05-01

    The low strain reflection wave method plays a principal rule in the integrating detection of base piles. However, there are some deficiencies with this method. For example, there is a blind area of detection on top of the tested pile; it is difficult to recognize the defects at deep-seated parts of the pile; there is still the planar of 3D domino effect, etc. It is very difficult to solve these problems only with the single-transducer pile integrity testing system. A new multi-signal piles integrity testing system is proposed in this paper, which is able to impulse and collect signals on multiple points on top of the pile. By using the multiple superposition data processing method, the detecting system can effectively restrain the interference and elevate the precision and SNR of pile integrity testing. The system can also be applied to the evaluation of engineering structure health.

  18. Developments of sensitive immunoassays for detection of antibodies against hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Ionescu-Matiu, I; Sanchez, Y; Dreesman, G R [Baylor Univ., Houston, TX (USA). Coll. of Medicine; Fields, H A [Centers for Disease Control, Public Health Service, Department of Health and Human Services, Phoenix, AZ (USA)

    1983-01-01

    Three micro solid phase immunoassays (a micro-SPRIA and two ELISA techniques) were developed and tested for the detection of anti-HBs antibodies. Two different crosslinkers (glutaraldehyde and N-succinimidyl 3-(2-pyridyldithio) propionate) were used to couple a goat anti-mouse IgG reagent to alkaline phosphatase for use as enzyme-labeled probes in the two ELISA tests. With the latter cross-linker, a defined conjugate with a 1 : 1 antibody-enzyme molar ratio was obtained. The sensitivities of micro-SPRIA and the two types of ELISA were compared to that of the commercial solid phase radioimmunoassay AUSAB test. All three microtests were significantly more sensitive than the AUSAB test. The ELISA using the glutaraldehyde cross-linked conjugate was 3-5 times less sensitive than micro-SPRIA, while the ELISA using the disulfide-linked conjugate was 2.6-4.0 times more sensitive than micro-SPRIA.

  19. Development of a Novel, Ultra-rapid Biosensor for the Qualitative Detection of Hepatitis B Virus-associated Antigens and Anti-HBV, Based on “Membrane-engineered” Fibroblast Cells with Virus-Specific Antibodies and Antigens

    Directory of Open Access Journals (Sweden)

    Antonios Perdikaris

    2009-03-01

    Full Text Available A novel miniature cell biosensor detection system for the detection of Hepatis B virus (HBV-associated antigens and anti-HBV is described. The biosensor is based on “membrane-engineered” Vero fibroblast cells immobilized in an alginate matrix. The membrane-engineering process involved the electroinsertion of anti-HBV specific antibodies (anti-HBs, anti-HBe or antigens (HBsAg in the membranes of the Vero cells. The attachment of a homologous antigen to the electroinserted antibody (or, respectively, of the antibody to the electroinserted antigen triggered specific changes to the cell membrane potential that were measured by appropriate microelectrodes, according to the principle of the Bioelectric Recognition Assay (BERA. The sensor was used for screening 133 clinical blood serum samples according to a double-blind protocol. Considerably higher sensor responses were observed against HBV-positive samples, compared with responses against negative samples or samples positive for heterologous hepatitis viruses such as Hepatitis C (HCV virus. Detection of anti-HBs antibodies was made possible by using a biosensor based on immobilized Vero cells bearing the respective antigen (HBsAg. The observed response was rapid (45 sec and quite reproducible. Fluorescence microscopy observations showed that attachment of HBV particles to cells membrane-engineered with anti-HBs was associated with a decrease of [Ca2+]cyt. The perspectives for using the novel biosensor as a qualitative, rapid screening, high throughput assay for HBV antigens and anti-HBs in clinical samples is discussed.

  20. Hepatitis B virus surface antigen and anti-hepatitis C virus rapid tests underestimate hepatitis prevalence among HIV-infected patients.

    Science.gov (United States)

    Hønge, Bl; Jespersen, S; Medina, C; Té, Ds; da Silva, Zj; Ostergaard, L; Laursen, Al; Wejse, C; Krarup, H; Erikstrup, C

    2014-10-01

    In the case of coinfection with HIV and hepatitis B virus (HBV) and/or hepatitis C virus (HCV), hepatic disease progression is often accelerated, with higher rates of liver cirrhosis and liver-related mortality. We aimed to evaluate the performance of the rapid tests used routinely to detect HBV surface antigen (HBsAg) and anti-HCV among HIV-infected patients in Guinea-Bissau. Blood samples from HIV-infected patients in Guinea-Bissau were stored after testing for HBsAg and anti-HCV with rapid tests. Samples were subsequently re-tested for HBsAg and anti-HCV in Denmark. Two rapid tests were used in Guinea-Bissau: HBsAg Strip Ref 2034 (VEDA.LAB, Alençon, France; sensitivity 62.3%; specificity 99.2%) and HEPA-SCAN (Bhat Bio-Tech, Bangalore, India; sensitivity 57.1%; specificity 99.7%). In the two tests the ability to obtain the correct outcome depended on the antigen and antibody concentrations, respectively. Sex, age, CD4 cell count and antiretroviral therapy status did not differ between false negative and true positive samples in either of the tests. The study is limited by a low number of anti-HCV positive samples. New diagnostic rapid tests should always be evaluated in the setting in which they will be used before implementation. © 2014 British HIV Association.

  1. Use of a solid-phase radioimmunoassay and formalin-fixed whole bacterial antigen in the detection of antigen-specific immunoglobulin in prostatic fluid.

    OpenAIRE

    Shortliffe, L M; Wehner, N; Stamey, T A

    1981-01-01

    The prostatic fluid of two patients with Escherichia coli bacterial prostatitis was analyzed for evidence of a local immune response to bacterial infection. A solid-phase radioimmunoassay was modified to measure the immunoglobulin (Ig)A and IgG antigen-specific antibody responses to infecting bacteria in serum and prostatic fluid from patient. Formalin-fixed whole E. coli were used as antigen. In one patient with acute E. coli prostatic infection, measurements of antigen-specific antibody con...

  2. Inaccuracy of Enzyme-Linked Immunosorbent Assay Using Soluble and Recombinant Antigens to Detect Asymptomatic Infection by Leishmania infantum

    Science.gov (United States)

    Moreno, Elizabeth Castro; Gonçalves, Andréa Vieira; Chaves, Anderson Vieira; Melo, Maria Norma; Lambertucci, José Roberto; Andrade, Antero Silva Ribeiro; Negrão-Corrêa, Deborah; Antunes, Carlos Mauricio de Figueiredo; Carneiro, Mariângela

    2009-01-01

    Background One of the most important drawbacks in visceral leishmaniasis (VL) population studies is the difficulty of diagnosing asymptomatic carriers. The aim of this study, conducted in an urban area in the Southeast of Brazil, was to evaluate the performance of serology to identify asymptomatic VL infection in participants selected from a cohort with a two-year follow-up period. Methodology Blood samples were collected in 2001 from 136 cohort participants (97 positive and 39 negatives, PCR/hybridization carried out in 1999). They were clinically evaluated and none had progressed to disease from their asymptomatic state. As controls, blood samples from 22 control individuals and 8 patients with kala-azar were collected. Two molecular biology techniques (reference tests) were performed: PCR with Leishmania-generic primer followed by hybridization using L. infantum probe, and PCR with specific primer to L. donovani complex. Plasma samples were tested by ELISA using three different antigens: L. infantum and L. amazonensis crude antigens, and rK39 recombinant protein. Accuracy of the serological tests was evaluated using sensitivity, specificity, likelihood ratio and ROC curve. Findings The presence of Leishmania was confirmed, by molecular techniques, in all kala-azar patients and in 117 (86%) of the 136 cohort participants. Kala-azar patients showed high reactivity in ELISAs, whereas asymptomatic individuals presented low reactivity against the antigens tested. When compared to molecular techniques, the L. amazonensis and L. infantum antigens showed higher sensitivity (49.6% and 41.0%, respectively) than rK39 (26.5%); however, the specificity of rK39 was higher (73.7%) than L. amazonensis (52.6%) and L. infantum antigens (36.8%). Moreover, there was low agreement among the different antigens used (kappa<0.10). Conclusions Serological tests were inaccurate for diagnosing asymptomatic infections compared to molecular methods; this could lead to misclassification bias

  3. Detection and Antigenic Profiling of Undeclared Peanut in Imported Garlic Using an xMAP Multiplex Immunoassay for Food Allergens.

    Science.gov (United States)

    Pedersen, Ronnie O; Peters, Tim; Panda, Rakhi; Wehling, Paul; Garber, Eric A E

    2017-07-01

    A shipment of imported garlic powder was suspected of containing peanut. Samples (subs) collected from the shipment displayed considerable variability in peanut antigenicity when analyzed by enzyme-linked immunosorbent assay (ELISA). This raised questions regarding whether peanut was actually present, the amount present, and the basis for the variability in antigenic content. Analyses that used an xMAP multiplex assay for the detection of peanut and additional food allergens generated responses that were characteristic of peanut. Specifically, the relative intensities of two different peanut-specific antibodies coupled to beads (peanut-37 and -38) and the antigen profiles were identical to garlic controls spiked with peanut. In addition, the xMAP data did not indicate the presence of other allergens. Quantitative analyses indicated an approximately fivefold variation in peanut concentration among different subs. In contrast, within a sub, the apparent peanut concentration appeared constant. Particle size analyses of the garlic powder subs indicated a single distribution profile, with a peak at 380 μm. ELISA analysis of sieve-fractionated garlic powder from one of the subs indicated that slightly less than half of the detectable peanut was smaller than 212 μm, with the remainder almost evenly split between 212 and 300 μm and >300 μm. Modeling to predict possible oral exposure levels of peanut other than those directly measured requires additional research on the physicochemical properties of peanut and garlic, along with information on the production of the garlic powder.

  4. Development of a T7 Phage Display Library to Detect Sarcoidosis and Tuberculosis by a Panel of Novel Antigens

    Directory of Open Access Journals (Sweden)

    Harvinder Talwar

    2015-04-01

    Full Text Available Sarcoidosis is a granulomatous inflammatory disease, diagnosed through tissue biopsy of involved organs in the absence of other causes such as tuberculosis (TB. No specific serologic test is available to diagnose and differentiate sarcoidosis from TB. Using a high throughput method, we developed a T7 phage display cDNA library derived from mRNA isolated from bronchoalveolar lavage (BAL cells and leukocytes of sarcoidosis patients. This complex cDNA library was biopanned to obtain 1152 potential sarcoidosis antigens and a microarray was constructed to immunoscreen two different sets of sera from healthy controls and sarcoidosis. Meta-analysis identified 259 discriminating sarcoidosis antigens, and multivariate analysis identified 32 antigens with a sensitivity of 89% and a specificity of 83% to classify sarcoidosis from healthy controls. Additionally, interrogating the same microarray platform with sera from subjects with TB, we identified 50 clones that distinguish between TB, sarcoidosis and healthy controls. The top 10 sarcoidosis and TB specific clones were sequenced and homologies were searched in the public database revealing unique epitopes and mimotopes in each group. Here, we show for the first time that immunoscreenings of a library derived from sarcoidosis tissue differentiates between sarcoidosis and tuberculosis antigens. These novel biomarkers can improve diagnosis of sarcoidosis and TB, and may aid to develop or evaluate a TB vaccine.

  5. Detection and partial characterization of a midlamina lucida-hemidesmosome-associated antigen (19-DEJ-1) present within human skin

    DEFF Research Database (Denmark)

    Fine, J D; Horiguchi, Y; Jester, J

    1989-01-01

    , esophagus, cervix, and cornea, and BMs surrounding smooth muscle in medium-sized vessels, placenta, uterus, and esophagus. When 16 human fetal skins (aged 54-142 gestational days) were examined, the antigen was first detected at 81 days. Using immunoperoxidase and immunogold staining techniques, indirect......A murine anti-human monoclonal antibody (19-DEJ-1) has been produced that binds to basement membranes (BMs) of the dermoepidermal junction and arrector pili muscles but not to either dermal glandular or vascular BMs. 19-DEJ-1 also recognizes BMs underneath epithelia of buccal mucosa, tongue......-specific proteoglycan that is present within BMs along the epithelial-connective tissue interface and around smooth muscle in skin and other selected organs. Its unique ultrastructural localization suggests the possibility that 19-DEJ-1 may recognize an antigenic epitope of either anchoring filaments or alternatively...

  6. Detection and localization of rabbit hepatitis e virus and antigen in systemic tissues from experimentally intraperitoneally infected rabbits.

    Directory of Open Access Journals (Sweden)

    Jingjing Mao

    Full Text Available Rabbit hepatitis E virus (HEV is a novel genotype of HEV, and is considered to pose a risk of zoonotic transmission. Research into the systemic distribution of rabbit HEV in rabbits during different periods of infection has rarely been reported. To better understand this virus, we infected rabbits with second-passage rabbit HEV via an intraperitoneal route. After inoculation, the infection showed two types, temporary and constant infection. The detection of HEV RNA in the feces varied with time, and serum antigen correlated with fecal HEV RNA. Viremia only appeared 72 days after inoculation. The rabbits remained antibody negative throughout the experimental period. When HEV was localized, several organs besides the liver were HEV RNA positive. Tissue antigen was observed immunohistochemically in the different cells of various organs, especially in parts of the small intestine and the characteristic rabbit gut-associated lymphoid tissue. These data provide valuable information for future research into the pathogenesis of HEV.

  7. Oriented Immobilization of Fab Fragments by Site-Specific Biotinylation at the Conserved Nucleotide Binding Site for Enhanced Antigen Detection.

    Science.gov (United States)

    Mustafaoglu, Nur; Alves, Nathan J; Bilgicer, Basar

    2015-09-08

    Oriented immobilization of antibodies and antibody fragments has become increasingly important as a result of the efforts to reduce the size of diagnostic and sensor devices to miniaturized dimensions for improved accessibility to the end-user. Reduced dimensions of sensor devices necessitate the immobilized antibodies to conserve their antigen binding activity for proper operation. Fab fragments are becoming more commonly used in small-scaled diagnostic devices due to their small size and ease of manufacture. In this study, we used the previously described UV-NBS(Biotin) method to functionalize Fab fragments with IBA-EG11-Biotin linker utilizing UV energy to initiate a photo-cross-linking reaction between the nucleotide binding site (NBS) on the Fab fragment and IBA-Biotin molecule. Our results demonstrate that immobilization of biotinylated Fab fragments via UV-NBS(Biotin) method generated the highest level of immobilized Fab on surfaces when compared to other typical immobilization methods while preserving antigen binding activity. UV-NBS(Biotin) method provided 432-fold, 114-fold, and 29-fold improved antigen detection sensitivity than physical adsorption, NHS-Biotin, and ε-NH3(+), methods, respectively. Additionally, the limit of detection (LOD) for PSA utilizing Fab fragments immobilized via UV-NBS(Biotin) method was significantly lower than that of the other immobilization methods, with an LOD of 0.4 pM PSA. In summary, site-specific biotinylation of Fab fragments without structural damage or loss in antigen binding activity provides a wide range of application potential for UV-NBS immobilization technique across numerous diagnostic devices and nanotechnologies.

  8. A sensitive immunoradiometric assay for the detection of hepatitis B surface antigen

    International Nuclear Information System (INIS)

    Cameron, C.H.; Combridge, B.S.; Howell, D.R.; Barbara, J.A.J.

    1980-01-01

    A solid-phase immunoradiometric assay for hepatitis B surface antigen is described which has been in use since 1972. Initially it was used for reference laboratory work, but from 1974 it has also been used for screening blood and blood products. Methods for the production of reagents and their use in blood transfusion and reference work, are outlined. (Auth.)

  9. Method to conjugate polysaccharide antigens to surfaces for the detection of antibodies

    DEFF Research Database (Denmark)

    Boas, Ulrik; Lind, Peter; Riber, Ulla

    2014-01-01

    microbeads modified with N-alkyl hydroxylamine and N-alkyl-O-methyl hydroxylamine surface groups by incubation of antigen and beads for 16 h at 40 oC without the need for coupling agents. The efficiency of the new method was evaluated by flow cytometry in model samples and serum samples containing antibodies...

  10. Detection of immune-complex-dissociated nonstructural-1 antigen in patients with acute dengue virus infections

    NARCIS (Netherlands)

    P. Koraka (Penelope); C.P. Burghoorn-Maas; A. Falconar; T.E. Setiati (Tatty); K. Djamiatun; J. Groen (Jan); A.D.M.E. Osterhaus (Albert)

    2003-01-01

    textabstractAccurate and timely diagnosis of dengue virus (DEN) infections is essential for the differential diagnosis of patients with febrile illness and hemorrhagic fever. In the present study, the diagnostic value of a newly developed immune-complex dissociated nonstructural-1 (NS-1) antigen dot

  11. Detection of immune-complex-dissociated nonstructural-1 antigen in patients with acute dengue virus infections.

    NARCIS (Netherlands)

    Koraka, P.; Burghoorn-Maas, C.P.; Falconar, A.; Setiati, T.E.; Djamiatun, K.; Groen, J.; Osterhaus, A.D.

    2003-01-01

    Accurate and timely diagnosis of dengue virus (DEN) infections is essential for the differential diagnosis of patients with febrile illness and hemorrhagic fever. In the present study, the diagnostic value of a newly developed immune-complex dissociated nonstructural-1 (NS-1) antigen dot blot

  12. MHC-based detection of antigen-specific CD8(+) T cell responses

    DEFF Research Database (Denmark)

    Hadrup, Sine Reker; Schumacher, Nana Maria Pii

    2010-01-01

    The hallmark of adaptive immunity is its ability to recognise a wide range of antigens and technologies that capture this diversity are therefore of substantial interest. New methods have recently been developed that allow the parallel analysis of T cell reactivity against vast numbers of different...

  13. The Use and Results of Prostate-Specific Antigen Testing in General Practice in the Former Aarhus County

    DEFF Research Database (Denmark)

    Mukai, Thomas; Bro, Flemming; Pedersen, Knud Venborg

    Background: Prostate Cancer (PC) is the most common type of cancer among Danish men, and the incidence is increasing. PC is often asymptomatic, making it difficult to establish a clinical diagnosis. The general practitioner can use prostate-specific antigen (PSA) testing as a tool for diagnosing PC...

  14. Studies into laboratory animals for clearance rate of 32P-labelled Brucellae, using antigen elimination test after biotechnological treatment

    International Nuclear Information System (INIS)

    Lusky, K.; Hoffmann, A.; Bache, K.; Mueller, M.; Zwies, G.

    1988-01-01

    Studies were performed for the purpose of assessment of the immune status of mice, with regard to literature data and taking into consideration the large-scale use of veterinary pharmaceuticals for biotechnological control of reproduction. The antigen elimination test with Brucellae was applied to ICR mice but no influence on the immune status of 6 consecutive generations could be demonstrated. (author)

  15. Antigen detection in vivo after immunization with different presentation forms of rabies virus antigen: Involvement of marginal metallophilic macrophages in the uptake of immune-stimulating complexes

    NARCIS (Netherlands)

    Claassen, I.J.T.M.; Osterhaus, A.D.M.E.; Claassen, E.

    1995-01-01

    Several mechanisms have been postulated to explain the relatively high immunogenicity of antigens presented in immune-stimulating complexes (iscom). Their potency can in part be explained by the specific targeting of these structures to cells presenting antigens to the immune system. However, until

  16. Antigen detection in vivo after immunization with different presentation forms of rabies virus antigen: involvement of marginal metallophilic macrophages in the uptake of immune-stimulating complexes.

    NARCIS (Netherlands)

    I.J.Th.M. Claassen (Ivo); A.D.M.E. Osterhaus (Albert); H.J.H.M. Claassen (Eric)

    1995-01-01

    textabstractSeveral mechanisms have been postulated to explain the relatively high immunogenicity of antigens presented in immune-stimulating complexes (iscom). Their potency can in part be explained by the specific targeting of these structures to cells presenting antigens to the immune system.

  17. Comparison of a stool antigen detection kit and PCR for diagnosis of Entamoeba histolytica and Entamoeba dispar infections in asymptomatic cyst passers in Iran.

    Science.gov (United States)

    Solaymani-Mohammadi, Shahram; Rezaian, Mostafa; Babaei, Zahra; Rajabpour, Azam; Meamar, Ahmad R; Pourbabai, Ahmad A; Petri, William A

    2006-06-01

    The present study was conducted to compare stool antigen detection with PCR for the diagnosis of Entamoeba sp. infection in asymptomatic cyst passers from Iran. Entamoeba dispar and, in one case, E. moshkovskii were the Entamoeba spp. found in the amebic cyst passers. There was a 100% correlation between the results from the TechLab E. histolytica II stool antigen kit and those from nested PCR. We concluded that E. dispar is much more common in asymptomatic cyst passers in Iran and that antigen detection and PCR are comparable diagnostic modalities.

  18. Detection of the circulating antigen 14-3-3 protein of Schistosoma japonicum by time-resolved fluoroimmunoassay in rabbits

    Directory of Open Access Journals (Sweden)

    Wang Jie

    2011-05-01

    Full Text Available Abstract Background Schistosomiasis remains a major public health concern that afflicts millions of people worldwide. Low levels of Schistosoma infection require more sensitive diagnostic methods. In this study, a time-resolved fluoroimmunoassay (TRFIA was developed for detecting the signal transduction protein 14-3-3, a circulating antigen of Schistosoma japonicum. Results The detection limit of 14-3-3-TRFIA was 0.78 ng/ml, with a linear measurement range from 0.78 to 800 ng/ml. The average intra-assay and inter-assay variability of this TRFIA was 8.9% and 12.2% respectively, and the mean recovery rate ranged from 92.1% to 115.5%. Within the first 21 days post-infection in rabbits, the positive rates of the 14-3-3-TRFIA were distinctly higher compared to ELISA. All these findings illustrate that 14-3-3-TRFIA has a higher detection efficacy and is a good early diagnostic method for active Schistosoma infection. Conclusions A sandwich TRFIA for detecting the circulating antigen 14-3-3 of S. japonicum has been developed, and has demonstrated to be a good potential diagnostic method for schistosomiasis.

  19. A Two-Step Lyssavirus Real-Time Polymerase Chain Reaction Using Degenerate Primers with Superior Sensitivity to the Fluorescent Antigen Test

    Directory of Open Access Journals (Sweden)

    Vanessa Suin

    2014-01-01

    Full Text Available A generic two-step lyssavirus real-time reverse transcriptase polymerase chain reaction (qRT-PCR, based on a nested PCR strategy, was validated for the detection of different lyssavirus species. Primers with 17 to 30% of degenerate bases were used in both consecutive steps. The assay could accurately detect RABV, LBV, MOKV, DUVV, EBLV-1, EBLV-2, and ABLV. In silico sequence alignment showed a functional match with the remaining lyssavirus species. The diagnostic specificity was 100% and the sensitivity proved to be superior to that of the fluorescent antigen test. The limit of detection was ≤1 50% tissue culture infectious dose. The related vesicular stomatitis virus was not recognized, confirming the selectivity for lyssaviruses. The assay was applied to follow the evolution of rabies virus infection in the brain of mice from 0 to 10 days after intranasal inoculation. The obtained RNA curve corresponded well with the curves obtained by a one-step monospecific RABV-qRT-PCR, the fluorescent antigen test, and virus titration. Despite the presence of degenerate bases, the assay proved to be highly sensitive, specific, and reproducible.

  20. A two-step lyssavirus real-time polymerase chain reaction using degenerate primers with superior sensitivity to the fluorescent antigen test.

    Science.gov (United States)

    Suin, Vanessa; Nazé, Florence; Francart, Aurélie; Lamoral, Sophie; De Craeye, Stéphane; Kalai, Michael; Van Gucht, Steven

    2014-01-01

    A generic two-step lyssavirus real-time reverse transcriptase polymerase chain reaction (qRT-PCR), based on a nested PCR strategy, was validated for the detection of different lyssavirus species. Primers with 17 to 30% of degenerate bases were used in both consecutive steps. The assay could accurately detect RABV, LBV, MOKV, DUVV, EBLV-1, EBLV-2, and ABLV. In silico sequence alignment showed a functional match with the remaining lyssavirus species. The diagnostic specificity was 100% and the sensitivity proved to be superior to that of the fluorescent antigen test. The limit of detection was ≤ 1 50% tissue culture infectious dose. The related vesicular stomatitis virus was not recognized, confirming the selectivity for lyssaviruses. The assay was applied to follow the evolution of rabies virus infection in the brain of mice from 0 to 10 days after intranasal inoculation. The obtained RNA curve corresponded well with the curves obtained by a one-step monospecific RABV-qRT-PCR, the fluorescent antigen test, and virus titration. Despite the presence of degenerate bases, the assay proved to be highly sensitive, specific, and reproducible.

  1. Detection of Antibody to Envelope (E2 Antigen of Hepatitis C Virus

    Directory of Open Access Journals (Sweden)

    RK Chaudhary

    1997-01-01

    Full Text Available One hundred and four clinical specimens from provincial public health laboratories were tested for antibody to hepatitis C virus (HCV envelope protein (anti-E2. To evaluate the effect of hypervariability of E2 region on anti-E2 assay, 49 recombinant immunoblot assay (RIBA 3.0 positive samples were genotyped. All 49 genotyped samples were positive for anti-E2. Eight of 12 (67% indeterminate, HCV RNA positive samples were anti-E2 reactive. Nine of 30 (30% indeterminate, HCV RNA negative samples were also positive for anti-E2. Anti-E2 was detected in two of 13 (15% RIBA-negative and enzyme immunoassays-positive samples. Although small number of samples were tested, the results showed that it may be possible to resolve indeterminate samples with the anti-E2 assay.

  2. Detection of GAD-Ab index in diabetic patients using 35S labeled recombinant human GAD65 antigen

    International Nuclear Information System (INIS)

    Huang Gan; Zhao Zhiguang; Peng Jian; Yan Xiang; Zhu Xuping; Yang Lin; Li Xia; Wang Jianping; Jiang Tiejian

    2003-01-01

    Objective: To establish a novel method for measuring glutamic acid decarboxylase autoanti-bodies(GAD-Ab). Methods: Recombinant human GAD 65 was used as the antigen, in vitro transcribed and translated 35 S-GAD 65 as the tracer, a self-designed rotating incubation apparatus as the incubator, protein-A sepharose as the precipitator, and the liquid scintillation counter was used to measure radioactive count value to detect GAD-Ab. The positive cut-off point of GAD-Ab index was determined as > 0.05 by the 99.5% percentile in 109 healthy individuals. GAD-Ab levels were determined in 43 type 1 and 226 type 2 diabetic patients. Results: The optimized working conditions included SJ1515 35 S-methionine for in vitro transcription and translation, 20-30 r/min setup of rotating incubation apparatus, test temperature 4-25 degree C, freshly prepared buffer of pH 7.2-7.4, and horizontal rotor centrifuge. The new method was better than original one, with intra-assay CV of 4.9%-8.3% and inter-assay CV of 7.1%-10.8 %, specificity of 98.2%. The results were comparable with the figures issued by an international standardized laboratory (concordance was 98.3%, Kappa value 0.971). The positive rate of GAD-Ab was 58.1% (25 of 43) in type 1 and 10.2%(23 of 226) in type 2 diabetes patients, but only 1.8% (2 of 109) in healthy individuals. Conclusion: The new assay for GAD-Ab is a highly sensitive, accurate, specific and reproducible method for clinical use

  3. Trypanosomosis surveillance on Zanzibar island, using the trypanosomal antigen detection ELISA (enzyme-linked immunosorbent assay) technique

    Energy Technology Data Exchange (ETDEWEB)

    Mbwambo, H A [Animal Disease Research Inst. (ADRI), Dar-es-Salaam (Tanzania, United Republic of)

    1997-02-01

    The effectiveness of trypanosomosis control programs depends greatly on prior knowledge of basic data of the epidemiological situation of the disease, which in turns depends, among others, on the use of techniques that give a fairly quick and accurate diagnosis. An antigen-detection (Ag) ELISA was first introduced into Tanzania and validated at the Animal Disease Research Institute (ADRI) through the FAO/IAEA Research Contract (RC) No. 5030/NL. Incorporation of the Ag-ELISA technique into a FAO animal disease control project (1986-1993) on Unguja island, in 1992, revealed useful information of high trypanosomosis prevalence in an area previously declared free of the disease using just stained blood smears and buffy coat examinations. This triggered further efforts into more intensive surveys of the tsetse and trypanosomosis situation on Unguja island. The present study is a continuation of previous work in an effort to confirm the practical application of Ag-ELISA in trypanosomosis control operations. Results obtained from a known tsetse and trypanosomosis-free area, on Pemba island, showed a high specificity of the test for Trypanosoma congolense, T. vivax and T. brucei. A preliminary cut-off value of 10% (Percent Positivity = PP) was used. When the PP of 10 was used on sera of trypanosomosis-endemic areas (Mangapwani, Ndijani, Dunga and Kikungwi) on Unguja island, the results reflected the `real` trypanosomis situation in the affected area. This was most strongly felt in the Mangapwani area, where tsetse and trypanosomosis were considered under control by 1994 (no tsetse flies were caught and no samples were encountered positive by the buffy coat technique). However, it should be stressed that the buffy coat technique and the Ag-ELISA complement each other and should be used in conjunction. (author). 8 refs, 1 fig., 5 tabs.

  4. Trypanosomosis surveillance on Zanzibar island, using the trypanosomal antigen detection ELISA (enzyme-linked immunosorbent assay) technique

    International Nuclear Information System (INIS)

    Mbwambo, H.A.

    1997-01-01

    The effectiveness of trypanosomosis control programs depends greatly on prior knowledge of basic data of the epidemiological situation of the disease, which in turns depends, among others, on the use of techniques that give a fairly quick and accurate diagnosis. An antigen-detection (Ag) ELISA was first introduced into Tanzania and validated at the Animal Disease Research Institute (ADRI) through the FAO/IAEA Research Contract (RC) No. 5030/NL. Incorporation of the Ag-ELISA technique into a FAO animal disease control project (1986-1993) on Unguja island, in 1992, revealed useful information of high trypanosomosis prevalence in an area previously declared free of the disease using just stained blood smears and buffy coat examinations. This triggered further efforts into more intensive surveys of the tsetse and trypanosomosis situation on Unguja island. The present study is a continuation of previous work in an effort to confirm the practical application of Ag-ELISA in trypanosomosis control operations. Results obtained from a known tsetse and trypanosomosis-free area, on Pemba island, showed a high specificity of the test for Trypanosoma congolense, T. vivax and T. brucei. A preliminary cut-off value of 10% (Percent Positivity = PP) was used. When the PP of 10 was used on sera of trypanosomosis-endemic areas (Mangapwani, Ndijani, Dunga and Kikungwi) on Unguja island, the results reflected the 'real' trypanosomis situation in the affected area. This was most strongly felt in the Mangapwani area, where tsetse and trypanosomosis were considered under control by 1994 (no tsetse flies were caught and no samples were encountered positive by the buffy coat technique). However, it should be stressed that the buffy coat technique and the Ag-ELISA complement each other and should be used in conjunction. (author). 8 refs, 1 fig., 5 tabs

  5. Avoiding false positive antigen detection by flow cytometry on blood cell derived microparticles: the importance of an appropriate negative control.

    Directory of Open Access Journals (Sweden)

    Emerence Crompot

    Full Text Available Microparticles (MPs, also called microvesicles (MVs are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results.We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets. Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM and Scanning Electron microscopy (SEM.Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins.We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.

  6. Comparison of a Recombinant-antigen Enzyme Immunoassay with Treponema pallidum Hemagglutination Test for Serological Confirmation of Syphilis

    Directory of Open Access Journals (Sweden)

    Rodríguez Islay

    2002-01-01

    Full Text Available A recombinant-antigen enzyme immunoassay (EIA, BioSCREEN TM anti-Treponema pallidum, was compared favorably with the T. pallidum hemagglutination test, in the detection of specific antibodies in different groups of sera from patients with primary (n = 38, secondary (n = 10, early latent (n = 28 and congenital syphilis (n = 2, patients with leptospirosis ( n= 8, infectious mononucleosis (n = 7, hepatitis (n = 9, diabetes mellitus (n = 11, rheumatoid arthritis (n = 13, leprosy (n = 11, tuberculosis (n = 9, HIV/Aids ( n= 12, systemic lupus erythematosus (n = 4, rheumatic fever (n = 3, old-persons (n = 9, pregnant women (n = 29 and blood donors (n = 164. The coincidence between them was 95.1%. The sensitivity and specificity of the EIA were 93.3% and 95.5%, respectively. Fifteen serum specimens belonging to old-persons, pregnant women, blood donors, and patients with human leptospirosis, hepatitis, diabetes mellitus, tuberculosis and rheumatic fever gave false-positive results by Venereal Disease Research Laboratory and/or Rapid Plasma Reagin. The EIA can be used as alternative method for the serological confirmation of syphilis.

  7. HCV Core Antigen Testing for Diagnosis of HCV Infection: A systematic review and meta-analysis

    Science.gov (United States)

    Freiman, J. Morgan; Tran, Trang M.; Schumacher, Samuel G; White, Laura F.; Ongarello, Stefano; Cohn, Jennifer; Easterbrook, Philippa J.; Linas, Benjamin P.; Denkinger, Claudia M.

    2017-01-01

    Background Diagnosis of chronic Hepatitis C Virus (HCV) infection requires both a positive HCV antibody screen and confirmatory nucleic acid test (NAT). HCV core antigen (HCVcAg) is a potential alternative to NAT. Purpose This systematic review evaluated the accuracy of diagnosis of active HCV infection among adults and children for five HCVcAg tests compared to NAT. Data Sources EMBASE, PubMed, Web of Science, Scopus, and Cochrane from 1990 through March 31, 2016. Study Selection Cohort, cross-sectional, and randomized controlled trials were included without language restriction Data Extraction Two independent reviewers extracted data and assessed quality using an adapted Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data Synthesis 44 studies evaluated 5 index tests. Studies for the ARCHITECT had the highest quality, while those for Ortho ELISA were the lowest. From bivariate analyses, the sensitivity and specificity with 95% CI were: ARCHITECT 93.4% (90.1, 96.4) and 98.8% (97.4, 99.5), Ortho ELISA 93.2% (81.6, 97.7) and 99.2% (87.9, 100), and Hunan Jynda 59.5% (46.0, 71.7) and 82.9% (58.6, 94.3). Insufficient data were available for a meta-analysis for Lumipulse and Lumispot. In three quantitative studies using ARCHITECT, HCVcAg correlated closely with HCV RNA above 3000 IU/mL. Limitations There was insufficient data on covariates such as HIV or HBV status for sub-group analyses. Few studies reported genotypes of isolates and there were scant data for genotypes 4, 5, and 6. Most studies were conducted in high resource settings within reference laboratories. Conclusions HCVcAg assays with signal amplification have high sensitivity, high specificity, and good correlation with HCV RNA above 3000 IU/mL. HCVcAg assays have the potential to replace NAT in high HCV prevalence settings. PMID:27322622

  8. Specific antigen serologic tests in leprosy: implications for epidemiological surveillance of leprosy cases and household contacts.

    Science.gov (United States)

    Carvalho, Ana Paula Mendes; Coelho, Angélica da Conceição Oliveira; Correa-Oliveira, Rodrigo; Lana, Francisco Carlos Félix

    2017-09-01

    There is a lack of straightforward tests for field application and known biomarkers for predicting leprosy progression in infected individuals. The aim was to analyse the response to infection by Mycobacterium leprae based on the reactivity of specific antigens: natural disaccharide linked to human serum albumin via an octyl (NDOHSA), a semisynthetic phenolic glycolipid-I (PGL-I); Leprosy Infectious Disease Research Institute Diagnostic-1 (LID-1) and natural disaccharide octyl - Leprosy Infectious Disease Research Institute Diagnostic-1 (NDOLID). The study population consisted of 130 leprosy cases diagnosed between 2010 and 2015 and 277 household contacts. An enzyme-linked immunosorbent assay (ELISA) was used to analyse the reactivity of antibodies against NDOHSA, LID-1 and NDOLID. The samples and controls were tested in duplicate, and the antibody titer was expressed as an ELISA index. Data collection was made by home visits with application of questionnaire and dermatological evaluation of all household contacts to identify signs and symptoms of leprosy. Significant differences in the median ELISA results were observed among leprosy cases in treatment, leprosy cases that had completed treatment and household contacts. Higher proportions of seropositivity were observed in leprosy cases in treatment. Seropositivity was also higher in multibacillary in relation to paucibacillary, with the difference reaching statistical significance. Lower titers were observed among cases with a longer treatment time or discharge. For household contacts, the differences according to the clinical characteristics of the leprosy index case were less pronounced than expected. Other factors, such as the endemicity of leprosy, exposure outside the residence and genetic characteristics, appeared to have a greater influence on the seropositivity. Serologic tests could be used as auxiliary tools for determining the operational classification, in addition to identifying infected individuals

  9. An indirect antibody assay using haptenated antigen and 125I-labelled anti-hapten antibody

    International Nuclear Information System (INIS)

    Aalberse, R.C.; Amsterdam Univ.

    1978-01-01

    Hapten (trinitrophenyl) was coupled to antigen (ovalbumin). The haptenated antigen was bound by anti-ovalbumin antibody and binding was quantitated with 125 I-labelled anti-hapten antibodies. Thus, with a single radioactive reagent, antibodies against a variety of antigens can be detected while the problems inherent in a labelled antiglobulin binding test are avoided. In the ovalbumin system, the haptenated antigen binding test proved to be approximately 20 times as sensitive as the iodinated ovalbumin binding test

  10. Detection of autoimmune antibodies in localized scleroderma by synthetic oligonucleotide antigens

    DEFF Research Database (Denmark)

    Samuelsen, Simone; Jørgensen, Christian Damsgaard; Mellins, Elizabeth D

    2018-01-01

    In this study, we developed a series of synthetic oligonucleotides that allowed us to investigate the details on the antigen recognition by autoimmune antibodies in localized scleroderma subjects. Besides dramatically improved analytical specificity of the assay, our data suggests a potential...... linking for antibodies to DNA to the biological status of disease state in localized scleroderma. Moreover, introducing chemical modifications into short synthetic deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) molecules completely changed the binding titers of corresponding antibodies...... and their clinical relevance. The strongest observed effect was registered for the localized scleroderma skin damage index (LoSDI) on the IgG antibodies to TC dinucleotide-rich double-stranded antigen (p

  11. [Recombinant OspC identification and antigenicity detection from Borrelia burgdorferi PD91 in China].

    Science.gov (United States)

    Chen, Jian; Wan, Kang-Lin

    2003-10-01

    To recombine OspC gene from Borrelia burgdorferi PD91 of China and expressed it in E. coli for early diagnosis of Lyme disease. The OspC gene was amplified from the genome of Borrelia burgdorferi PD91 strain by polymerase chain reaction and recombined with plasmid PET-11D. The recombinant plasmid PET-11D-OspC was identified with PCR, restriction endonuclease analysis and sequencing. The antigenicity was verified with Western Blot. OspC gene was cloned correctly into vector PET-11D. The resultant sequence was definitely different from the published sequence. The recombinant OspC seemed to have had strong antigenicity. The findings laid basis for the studies on early diagnosis of Lyme disease.

  12. A novel dendritic cell-based direct ex vivo assay for detection and enumeration of circulating antigen-specific human T cells.

    Science.gov (United States)

    Carrio, Roberto; Zhang, Ge; Drake, Donald R; Schanen, Brian C

    2018-05-07

    Although a variety of assays have been used to examine T cell responses in vitro, standardized ex vivo detection of antigen-specific CD4 + T cells from human circulatory PBMCs remains constrained by low-dimensional characterization outputs and the need for polyclonal, mitogen-induced expansion methods to generate detectable response signals. To overcome these limitations, we developed a novel methodology utilizing antigen-pulsed autologous human dendritic target cells in a rapid and sensitive assay to accurately enumerate antigen-specific CD4 + T cell precursor frequency by multiparametric flow cytometry. With this approach, we demonstrate the ability to reproducibly quantitate poly-functional T cell responses following both primary and recall antigenic stimulation. Furthermore, this approach enables more comprehensive phenotypic profiling of circulating antigen-specific CD4 + T cells, providing valuable insights into the pre-existing polarization of antigen-specific T cells in humans. Combined, this approach permits sensitive and detailed ex vivo detection of antigen-specific CD4 + T cells delivering an important tool for advancing vaccine, immune-oncology and other therapeutic studies.

  13. Screening Yield of HIV Antigen/Antibody Combination and Pooled HIV RNA Testing for Acute HIV Infection in a High-Prevalence Population.

    Science.gov (United States)

    Peters, Philip J; Westheimer, Emily; Cohen, Stephanie; Hightow-Weidman, Lisa B; Moss, Nicholas; Tsoi, Benjamin; Hall, Laura; Fann, Charles; Daskalakis, Demetre C; Beagle, Steve; Patel, Pragna; Radix, Asa; Foust, Evelyn; Kohn, Robert P; Marmorino, Jenni; Pandori, Mark; Fu, Jie; Samandari, Taraz; Gay, Cynthia L

    2016-02-16

    Although acute HIV infection contributes disproportionately to onward HIV transmission, HIV testing has not routinely included screening for acute HIV infection. To evaluate the performance of an HIV antigen/antibody (Ag/Ab) combination assay to detect acute HIV infection compared with pooled HIV RNA testing. Multisite, prospective, within-individual comparison study conducted between September 2011 and October 2013 in 7 sexually transmitted infection clinics and 5 community-based programs in New York, California, and North Carolina. Participants were 12 years or older and seeking HIV testing, without known HIV infection. All participants with a negative rapid HIV test result were screened for acute HIV infection with an HIV Ag/Ab combination assay (index test) and pooled human immunodeficiency virus 1 (HIV-1) RNA testing. HIV RNA testing was the reference standard, with positive reference standard result defined as detectable HIV-1 RNA on an individual RNA test. Number and proportion with acute HIV infections detected. Among 86,836 participants with complete test results (median age, 29 years; 75.0% men; 51.8% men who have sex with men), established HIV infection was diagnosed in 1158 participants (1.33%) and acute HIV infection was diagnosed in 168 participants (0.19%). Acute HIV infection was detected in 134 participants with HIV Ag/Ab combination testing (0.15% [95% CI, 0.13%-0.18%]; sensitivity, 79.8% [95% CI, 72.9%-85.6%]; specificity, 99.9% [95% CI, 99.9%-99.9%]; positive predictive value, 59.0% [95% CI, 52.3%-65.5%]) and in 164 participants with pooled HIV RNA testing (0.19% [95% CI, 0.16%-0.22%]; sensitivity, 97.6% [95% CI, 94.0%-99.4%]; specificity, 100% [95% CI, 100%-100%]; positive predictive value, 96.5% [95% CI, 92.5%-98.7%]; sensitivity comparison, P testing detected 82% of acute HIV infections detectable by pooled HIV RNA testing. Compared with rapid HIV testing alone, HIV Ag/Ab combination testing increased the relative HIV diagnostic yield (both

  14. Detection of survivin, carcinoembryonic antigen and ErbB2 level in oral squamous cell carcinoma patients.

    Science.gov (United States)

    Li, Shu-Xia; Yang, Yan-Qi; Jin, Li-Jian; Cai, Zhi-Gang; Sun, Zheng

    2016-01-01

    The aim of this study was to detect the survivin, carcinoembryonic antigen (CEA) and ErbB2 in the saliva, serum and local tumor-exfoliated cells of oral squamous cell carcinoma (OSCC) patients, for providing reliable tumor markers for the early detection of oral malignant cancer. The saliva, serum, and local tumor-exfoliated cell samples of 26 OSCC patients without chemotherapy and 10 non-cancer patients were collected in Department of Oral and Maxillofacial Surgery, School of Stomatology, Peking University. The contents of survivin, CEA and ErbB2 using were detected usingenzyme-linked immunosorbent assay. The survivin and CEA levels in saliva and local tumor-exfoliated cells of OSCC patients were significantly higher than those in the non-cancer patients (P oral malignant cancer.

  15. The simultaneous ex vivo detection of low-frequency antigen-specific CD4+ and CD8+ T-cell responses using overlapping peptide pools.

    Science.gov (United States)

    Singh, Satwinder Kaur; Meyering, Maaike; Ramwadhdoebe, Tamara H; Stynenbosch, Linda F M; Redeker, Anke; Kuppen, Peter J K; Melief, Cornelis J M; Welters, Marij J P; van der Burg, Sjoerd H

    2012-11-01

    The ability to measure antigen-specific T cells at the single-cell level by intracellular cytokine staining (ICS) is a promising immunomonitoring tool and is extensively applied in the evaluation of immunotherapy of cancer. The protocols used to detect antigen-specific CD8+ T-cell responses generally work for the detection of antigen-specific T cells in samples that have undergone at least one round of in vitro pre-stimulation. Application of a common protocol but now using long peptides as antigens was not suitable to simultaneously detect antigen-specific CD8+ and CD4+ T cells directly ex vivo in cryopreserved samples. CD8 T-cell reactivity to monocytes pulsed with long peptides as antigens ranged between 5 and 25 % of that observed against monocytes pulsed with a direct HLA class I fitting minimal CTL peptide epitope. Therefore, we adapted our ICS protocol and show that the use of tenfold higher concentration of long peptides to load APC, the use of IFN-α and poly(I:C) to promote antigen processing and improve T-cell stimulation, does allow for the ex vivo detection of low-frequency antigen-specific CD8+ and CD4+ T cells in an HLA-independent setting. While most of the improvements were related to increasing the ability to measure CD8+ T-cell reactivity following stimulation with long peptides to at least 50 % of the response detected when using a minimal peptide epitope, the final analysis of blood samples from vaccinated patients successfully showed that the adapted ICS protocol also increases the ability to ex vivo detect low-frequency p53-specific CD4+ T-cell responses in cryopreserved PBMC samples.

  16. Avoidance of anticipated regret: the ordering of prostate-specific antigen tests.

    Science.gov (United States)

    Sorum, Paul C; Mullet, Etienne; Shim, Junseop; Bonnin-Scaon, Sylvie; Chasseigne, Gérard; Cogneau, Joël

    2004-01-01

    When making decisions, people are known to try to minimize the regret that would be provoked by unwanted consequences of these decisions. The authors explored the strength and determinants of such anticipated regret in a study of physicians' decisions to order prostate-specific antigen (PSA) tests. 32 US and 33 French primary care physicians indicated the likelihood they would order a PSA for 32 hypothetical men presenting for routine physical exams. They then indicated how much regret they would feel if they found advanced prostate cancer in 12 other patients for whom they had chosen not to order PSAs several years before. The latter patients differed according to age (55, 65, or 75 years), a prior request or not for PSA testing, and no or some irregularity of the prostate on the earlier rectal exam. ANOVA found that regret was higher when the patient had requested a PSA, the prostate was irregular, and the patient was younger. Shape had less effect when the patient had requested a PSA. US physicians had more regret than the French, patient request had a greater impact on the Americans, and increasing patient age reduced regret more among the French. In a 1-way correlation, the regret score was associated with the likelihood of ordering PSAs for both the French (r = 0.64, P regret score was the most important predictor of the likelihood of ordering a PSA (beta = 0.37, P Regret over failing to diagnose aggressive prostate cancer is associated with a policy of ordering PSAs. This regret appears to be culturally sensitive.

  17. Psychological impact of serial prostate-specific antigen tests in Japanese men waiting for prostate biopsy.

    Science.gov (United States)

    Kobayashi, Minoru; Nukui, Akinori; Kamai, Takao

    2017-02-01

    It is common to repeat prostate-specific antigen (PSA) measurements for men with intermediate PSA elevation before prostate biopsy. In this scenario, men with persistently elevated PSA values may have considerable psychological distress. We attempted to determine whether elevated PSA values have psychological effects on these men in association with the timing of measurement, PSA kinetics, and biopsy results. In order to investigate the initial and late effects of PSA tests on psychological distress during serial measurements, two groups of men with screen-positive results (PSA ≥3 ng/ml) were studied-205 men whose first questionnaires regarding anxiety and depression were taken at initial screening (group A), and 103 men whose questionnaires were taken at repeated measurement for prior PSA elevation (group B). The level of distress was generally low. There were no significant differences in distress between the two groups, suggesting a constant psychological effect by elevated PSA values over a long period of time. The distress of men in group A increased significantly as PSA levels rose and decreased when they fell to normal range. On the other hand, the distress of men in group B did not change regardless of PSA kinetics, indicating that their psychological condition seemed susceptible to subtle PSA change only in the initial phase of measurements. Unexpectedly, men with benign results showed insignificant but higher distress after prostate biopsy. Although a small fraction of men have psychological distress caused by changes in PSA levels, the benefits, risks (psychological and physical), and limitations of PSA tests must be adequately explained to the patients before entering the screening program.

  18. Rapid antigen group A streptococcus test to diagnose pharyngitis: a systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Emily H Stewart

    Full Text Available BACKGROUND: Pharyngitis management guidelines include estimates of the test characteristics of rapid antigen streptococcus tests (RAST using a non-systematic approach. OBJECTIVE: To examine the sensitivity and specificity, and sources of variability, of RAST for diagnosing group A streptococcal (GAS pharyngitis. DATA SOURCES: MEDLINE, Cochrane Reviews, Centre for Reviews and Dissemination, Scopus, SciELO, CINAHL, guidelines, 2000-2012. STUDY SELECTION: Culture as reference standard, all languages. DATA EXTRACTION AND SYNTHESIS: Study characteristics, quality. MAIN OUTCOME(S AND MEASURE(S: Sensitivity, specificity. RESULTS: We included 59 studies encompassing 55,766 patients. Forty three studies (18,464 patients fulfilled the higher quality definition (at least 50 patients, prospective data collection, and no significant biases and 16 (35,634 patients did not. For the higher quality immunochromatographic methods in children (10,325 patients, heterogeneity was high for sensitivity (inconsistency [I(2] 88% and specificity (I(2 86%. For enzyme immunoassay in children (342 patients, the pooled sensitivity was 86% (95% CI, 79-92% and the pooled specificity was 92% (95% CI, 88-95%. For the higher quality immunochromatographic methods in the adult population (1,216 patients, the pooled sensitivity was 91% (95% CI, 87 to 94% and the pooled specificity was 93% (95% CI, 92 to 95%; however, heterogeneity was modest for sensitivity (I(2 61% and specificity (I(2 72%. For enzyme immunoassay in the adult population (333 patients, the pooled sensitivity was 86% (95% CI, 81-91% and the pooled specificity was 97% (95% CI, 96 to 99%; however, heterogeneity was high for sensitivity and specificity (both, I(2 88%. CONCLUSIONS: RAST immunochromatographic methods appear to be very sensitive and highly specific to diagnose group A streptococcal pharyngitis among adults but not in children. We could not identify sources of variability among higher quality studies. The

  19. Comparison of three stool antigen assays with the 13C- urea breath test for the primary diagnosis of Helicobacter pylori infection and monitoring treatment outcome.

    LENUS (Irish Health Repository)

    Hooton, Carmel

    2012-02-03

    BACKGROUND: The urea breath test (UBT) is the gold-standard non-invasive test for the detection of Helicobacter pylori infection, however, the lack of availability of the UBT due to the high cost of the test, and in particular the need for expensive analytical instrumentation, limits the usefulness of this method. Stool antigen assays may offer an alternative non-invasive method for the diagnosis of infection. OBJECTIVE: To compare the accuracy of three stool antigen assays (HpSA, IDEIA HpStAR, and ImmunoCard STAT) against the UBT for the primary diagnosis of H. pylori infection and for monitoring treatment outcome. METHODS: A total of 102 patients attending two gastroenterology day-case clinics for the investigation of dyspepsia were included. Each patient provided breath and stool samples for analysis. Patients who tested positive for H. pylori by the validated UBT were prescribed triple therapy and invited to return for repeat breath and stool sample analysis 6 weeks post-treatment. RESULTS: Of the 102 patients tested, 48 were diagnosed with H. pylori infection by the UBT. The HpSA assay interpreted 38 of these as positive (79% sensitive). Of the 54 UBT-negative patients the HpSA assay interpreted all 54 as negative (100% specific). The IDEIA HpStAR assay correctly identified 44 patients as positive (92% sensitive) and 50 as negative (92.5% specific). The ImmunoCard STAT assay interpreted 38 patients as positive (79% sensitive) and 52 as negative (96.3% specific). CONCLUSION: The findings indicate that the IDEIA HpStAR stool antigen kit is the most accurate assay of the three assays evaluated, and possibly represents a viable alternative to the UBT for the primary diagnosis of H. pylori infection and for monitoring treatment outcome.

  20. COLONOSCOPY AND CARCINOEMBRYONIC ANTIGEN VARIATIONS

    Directory of Open Access Journals (Sweden)

    Rita G SOUSA

    2014-03-01

    Full Text Available Context Colonoscopy is essential for synchronous and metachronous cancer detection. Carcinoembryonic antigen is a colorectal cancer tumor marker, important as a follow-up tool in patients with previous colorectal cancer. False-positive carcinoembryonic antigen elevation results in multiples exams and in patient anxiety. In literature, there is reference to transient carcinoembryonic antigen increase with colonoscopy. Objective To evaluate the influence of bowel preparation and colonoscopy in carcinoembryonic antigen blood levels. Methods We prospectively studied subjects that underwent routine colonoscopy in our institution. Blood samples were collected (1 before bowel cleaning, (2 before colonoscopy and (3 immediately after colonoscopy. Blood carcinoembryonic antigen levels were determined by “Sandwich” immunoassay. The statistical methods used were the paired t-test and ANOVA. Results Thirty-seven patients (22M/15F were included; age range 28-84 (mean 56 years. Mean carcinoembryonic antigen values were 1.9, 2 and 1.8 for (1, (2 and (3, respectively. An increase in value (2 compared with (1 was observed in 20/37 patients (P = 0.018, mainly in younger patients and in patients requiring more endoluminal interventions. In 29/37 patients, the CEA value decreased from (2 to (3 (P = 1.3x10-7. Conclusions A trend for carcinoembryonic antigen increase after bowel cleaning was observed, especially in younger patients and in patients with more endoluminal interventions, but without clinical meaning.

  1. Explosive simulants for testing explosive detection systems

    Science.gov (United States)

    Kury, John W.; Anderson, Brian L.

    1999-09-28

    Explosives simulants that include non-explosive components are disclosed that facilitate testing of equipment designed to remotely detect explosives. The simulants are non-explosive, non-hazardous materials that can be safely handled without any significant precautions. The simulants imitate real explosives in terms of mass density, effective atomic number, x-ray transmission properties, and physical form, including moldable plastics and emulsions/gels.

  2. CdSe/ZnS Quantum Dot-Labeled Lateral Flow Strips for Rapid and Quantitative Detection of Gastric Cancer Carbohydrate Antigen 72-4

    Science.gov (United States)

    Yan, Xinyu; Wang, Kan; Lu, Wenting; Qin, Weijian; Cui, Daxiang; He, Jinghua

    2016-03-01

    Carbohydrate antigen 72-4 (CA72-4) is an important biomarker associated closely with diagnosis and prognosis of early gastric cancer. How to realize quick, sensitive, specific, and quantitative detection of CA72-4 in clinical specimens has become a great requirement. Herein, we reported a CdSe/ZnS quantum dot-labeled lateral flow test strip combined with a charge-coupled device (CCD)-based reader was developed for rapid, sensitive, and quantitative detection of CA72-4. Two mouse monoclonal antibodies (mAbs) against CA72-4 were employed. One of them was coated as a test line, while another mAb was labeled with quantum dots and coated onto conjugate pad. The goat anti-mouse IgG was immobilized as a control line. After sample was added, a sandwich structure was formed with CA72-4 and these two mAbs. The fluorescent signal from quantum dots (QD)-labeled mAb in sandwich structure was related to the amount of detected CA72-4. A CCD-based reader was used to realize quantitative detection of CA72-4. Results showed that developed QD-labeled lateral flow strips to detect CA72-4 biomarker with the sensitivity of 2 IU/mL and 10 min detection time. One hundred sera samples from clinical patients with gastric cancer and healthy people were used to confirm specificity of this strip method; results showed that established strip method own 100 % reproducibility and 100 % specificity compared with Roche electrochemiluminescence assay results. In conclusion, CdSe/ZnS quantum dot-labeled lateral flow strips for detection of CA72-4 could realize rapid, sensitive, and specific detection of clinical samples and could own great potential in clinical translation in near future.

  3. Chimeric antigen receptor (CAR-specific monoclonal antibody to detect CD19-specific T cells in clinical trials.

    Directory of Open Access Journals (Sweden)

    Bipulendu Jena

    Full Text Available Clinical trials targeting CD19 on B-cell malignancies are underway with encouraging anti-tumor responses. Most infuse T cells genetically modified to express a chimeric antigen receptor (CAR with specificity derived from the scFv region of a CD19-specific mouse monoclonal antibody (mAb, clone FMC63. We describe a novel anti-idiotype monoclonal antibody (mAb to detect CD19-specific CAR(+ T cells before and after their adoptive transfer. This mouse mAb was generated by immunizing with a cellular vaccine expressing the antigen-recognition domain of FMC63. The specificity of the mAb (clone no. 136.20.1 was confined to the scFv region of the CAR as validated by inhibiting CAR-dependent lysis of CD19(+ tumor targets. This clone can be used to detect CD19-specific CAR(+ T cells in peripheral blood mononuclear cells at a sensitivity of 1∶1,000. In clinical settings the mAb is used to inform on the immunophenotype and persistence of administered CD19-specific T cells. Thus, our CD19-specific CAR mAb (clone no. 136.20.1 will be useful to investigators implementing CD19-specific CAR(+ T cells to treat B-lineage malignancies. The methodology described to develop a CAR-specific anti-idiotypic mAb could be extended to other gene therapy trials targeting different tumor associated antigens in the context of CAR-based adoptive T-cell therapy.

  4. New technology for regiospecific covalent coupling of polysaccharide antigens in ELISA for serological detection

    DEFF Research Database (Denmark)

    Jauho, E.S.; Boas, Ulrik; Wiuff, Camilla

    2000-01-01

    In this study we demonstrate a new UV irradiation technique for covalent coupling of bacterial polysaccharides derived from lipopolysaccharides to microtiter plates and the use of such plates in an enzyme linked immunosorbent assay (ELISA). Lipopolysaccharides were cleaved by mild acid hydrolysis...... describe the use of this technique for the immobilization of Lipopolysaccharide derived polysaccharides from Salmonella Typhimurium and Salmonella Choleraesuis lipopolysaccharides, representing the O-antigens 1, 4, 5, 6, 7, and 12, The functional polysaccharide surface gave similar ELISA results to plates...

  5. Test of TEDA, Tsunami Early Detection Algorithm

    Science.gov (United States)

    Bressan, Lidia; Tinti, Stefano

    2010-05-01

    Tsunami detection in real-time, both offshore and at the coastline, plays a key role in Tsunami Warning Systems since it provides so far the only reliable and timely proof of tsunami generation, and is used to confirm or cancel tsunami warnings previously issued on the basis of seismic data alone. Moreover, in case of submarine or coastal landslide generated tsunamis, which are not announced by clear seismic signals and are typically local, real-time detection at the coastline might be the fastest way to release a warning, even if the useful time for emergency operations might be limited. TEDA is an algorithm for real-time detection of tsunami signal on sea-level records, developed by the Tsunami Research Team of the University of Bologna. The development and testing of the algorithm has been accomplished within the framework of the Italian national project DPC-INGV S3 and the European project TRANSFER. The algorithm is to be implemented at station level, and it is based therefore only on sea-level data of a single station, either a coastal tide-gauge or an offshore buoy. TEDA's principle is to discriminate the first tsunami wave from the previous background signal, which implies the assumption that the tsunami waves introduce a difference in the previous sea-level signal. Therefore, in TEDA the instantaneous (most recent) and the previous background sea-level elevation gradients are characterized and compared by proper functions (IS and BS) that are updated at every new data acquisition. Detection is triggered when the instantaneous signal function passes a set threshold and at the same time it is significantly bigger compared to the previous background signal. The functions IS and BS depend on temporal parameters that allow the algorithm to be adapted different situations: in general, coastal tide-gauges have a typical background spectrum depending on the location where the instrument is installed, due to local topography and bathymetry, while offshore buoys are

  6. Prevalence of human immunodeficiency virus type 1 p24 antigen in U.S. blood donors--an assessment of the efficacy of testing in donor screening. The HIV-Antigen Study Group.

    Science.gov (United States)

    Alter, H J; Epstein, J S; Swenson, S G; VanRaden, M J; Ward, J W; Kaslow, R A; Menitove, J E; Klein, H G; Sandler, S G; Sayers, M H

    1990-11-08

    We performed a multicenter study in 1989 to determine whether screening whole-blood donors for human immunodeficiency virus type 1 (HIV-1) p24 antigen would improve transfusion safety by identifying carriers of the virus who are seronegative for HIV-1 antibody. More than 500,000 donations were tested at 13 U.S. blood centers with test kits from two manufacturers. Units found repeatedly reactive were retested in a central laboratory; if the results were positive, they were confirmed by a neutralization assay. A subgroup of units was also tested for HIV-1 by the polymerase chain reaction. Selected donors confirmed or not confirmed as having p24 antigen were contacted for follow-up interviews to identify risk factors and undergo retesting for HIV-1 markers. Positive tests for p24 antigen were confirmed by neutralization in five donors (0.001 percent of all donations tested), all of whom were also positive for HIV-1 antibody and HIV-1 by polymerase chain reaction. Three of the antigen-positive donors had other markers of infectious disease that would have resulted in the exclusion of their blood; two had risk factors for HIV-1 that should have led to self-exclusion. Of 220 blood units with repeatedly reactive p24 antigen whose presence could not be confirmed by neutralization (0.04 percent of the donations studied), none were positive for HIV-1 antibody, HIV-1 by polymerase chain reaction (120 units tested), or virus culture (76 units tested)--attesting to the specificity of confirmatory neutralization. The finding that no donation studied was positive for p24 antigen and negative for HIV-1 antibody suggests that screening donors for p24 antigen with tests of the current level of sensitivity would not add substantially to the safety of the U.S. blood supply.

  7. Application of 125I-labelled soluble proteins in the histoautoradiographic detection of antigen and antibodies in the spleen of rabbits during primary immune response

    International Nuclear Information System (INIS)

    Rodak, L.

    1975-01-01

    An autoradiographic method for detecting soluble antigen (chicken serum albumin, CSA) and specific antibodies in the spleen of rabbits during a primary immune response is described. The method consists of incubating sections from the spleen with 125 I-labelled IgG 2 anti CSA (for demonstration of antigen) or with 125 I-labelled antigen (for demonstration of specific antibodies). This treatment of histological sections combines the advantages and principles of the immunofluorescence technique with the possibility of evaluating the exact localization of the proteins by light microscopy in preparations stained with haematoxylin or methyl green-pyronin. The sensitivity of detection is very high: both antigen and antibodies could be demonstrated in the spleen follicles for as long as 42 days after the primary intravenous injection

  8. [Enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to Salmonella Typhi lipopolysaccharide O and capsular polysaccharide Vi antigens in persons from outbreak of typhoid fever].

    Science.gov (United States)

    Rastawicki, Waldemar; Kałużewski, Stanisław

    2015-01-01

    The laboratory diagnosis of typhoid fever is dependent upon either isolation of S. Typhi from a clinical sample or the detection of raised titers of serum antibodies in the Widal test or the passive hemagglutination assay (PHA). In this study we evaluated the usefulness of ELISA for detection of antibodies to S. Typhi lipopolysaccharide O and capsular polysaccharide Vi antigens in the sera of persons from outbreak of typhoid fever. Fifteen serum samples from patients with laboratory confirmed typhoid fever and 140 sera from persons suspected for contact with typhoid fever patients from outbreak in 1974/75 in Poland were tested by ELISA. Additionally, as the control group, we tested 115 sera from blood donors for the presence of S. Typhi anti-LPS and anti-Vi antibodies. Anti-LPS and anti-Vi antibodies were detected in 80% and 53.3% of sera obtained from patients with laboratory confirmed typhoid fever, respectively. The high percentages of positive results in ELISA were also noted in the group of persons suspected for contact with typhoid fever patients (51.4% and 45%) but not in the group of blood donors (7.8% and 6.1%, respectively). The ELISA could be a useful tool for the serological diagnosis of typhoid fever in patients who have clinical symptoms but are culture negative, especially during massive outbreaks of typhoid fever.

  9. Improvements on an ELISA to detect trypanosomal antigens and its use as a monitoring tool in tsetse and trypanosomosis control programmes

    International Nuclear Information System (INIS)

    Dwinger, R.H.; Rebeski, D.; Winger, E.

    1997-01-01

    Monoclonal antibodies directed at epitopes of Trypanosoma brucei, T. congolense and T. vivax have been used to capture and detect trypanosomal antigens in bovine blood samples using an enzyme-linked immunosorbent assay (ELISA) developed elsewhere. The test has been transformed in a ready-to-use kit format for distribution among a network of 15 African research institutes. The specificity of the test was assessed under experimental and field conditions and found to be 96% (± 2%) for T. brucei, 99.5% (±1%) for T. congolense and 99% (±1%) for T. vivax. Following a validation period under field conditions, adjustments were made to the protocol to increase the sensitivity of the ELISA and to improve the suitability of the test for laboratory use under African conditions. Presently the ag-ELISA is being applied in conjunction with conventional parasitological techniques such as the buffy coat technique (BCT) to monitor progress in various tsetse and trypanosomosis control programmes and in a tsetse eradication effort in the United Republic of Tanzania, on the island of Zanzibar. The two tests complement each other, since infections not detected by one test may be detected by the other. In general, the serological test tends to produce more false negatives during subacute infections, while the parasitological techniques tend to produce more false negatives during chronic infections. Since the sensitivity of the ELISA is not optimal, research efforts at the FAO/IAEA Agriculture and Biotechnology Laboratory will be focused on improving this aspect. However, these efforts are severely hampered by the lack of a diagnostic test that can be used as a ''gold standard''. The use of the polymerase chain reaction for verifying doubtful test results and as a possible candidate for a ''gold standard'' to diagnose trypanosomosis are discussed. Finally, future plans are outlined to initiate the use of geographical information systems to assess the impact of tsetse control and

  10. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer.

    Science.gov (United States)

    Bates, Anthony; Miles, Kenneth

    2017-12-01

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at prostate cancer. • Prostate transition zone (TZ) MR texture analysis may assist in prostate cancer detection. • Abnormal transition zone PSMA expression correlates with altered texture on T2-weighted MR. • TZ with abnormal PSMA expression demonstrates significantly reduced MI, SD and MPP.

  11. Efficacy of gamma irradiation on H5N1 for the preparation of hemagglutination Inhibition test antigen

    International Nuclear Information System (INIS)

    Chaisingh, Arunee; Thammasart, Suree; Kamolsiripichaiporn, Somjai; Piadang Nattayana

    2006-09-01

    The result of the efficiencies of gamma irradiation at the dose of 10-60 kGy on highly pathogenic avian influenza virus, H5N1 (Thai isolate) revealed that gamma irradiation at the dose of 10 and 20 kGy could reduce the infectivity of Hanna but gamma irradiation at 30-60 kGy could inactivate H5N1 virus completely. All doses of gamma irradiation used in this experiment had no effect on antigenicity of hemagglutinin protein. Thus, gamma irradiation at the dose of 30- 60 kGy could be use safely for the antigen preparation to detect the antibody against H5N1 virus.

  12. SCTI chemical leak detection test plan

    International Nuclear Information System (INIS)

    1981-01-01

    Tests will be conducted on the CRBRP prototype steam generator at SCTI to determine the effects of steam generator geometry on the response of the CRBRP chemical leak detection system to small water-to-sodium leaks in various regions of the steam generator. Specifically, small injections of hydrogen gas (simulating water leaks) will be made near the two tubesheets, and the effective transport times to the main stream exit and vent line hydrogen meters will be measured. The magnitude and time characteristics of the meters' response will also be measured. This information will be used by the Small Leak Protection Base Program (SG027) for improved predictions of meter response times and leak detection sensitivity

  13. Evaluation of enzyme-linked immunosorbent assays based on monoclonal antibodies for the serology and antigen detection in canine parvovirus infections.

    NARCIS (Netherlands)

    G.F. Rimmelzwaan (Guus); N. Juntti; B. Klingeborn; J. Groen (Jan); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1990-01-01

    textabstractAn enzyme-linked immunosorbent assay (ELISA) system was developed for the detection of canine parvovirus (CPV) or CPV antigen in dog faeces and two other ELISA systems were developed for the detection of CPV-specific antibodies in dog sera. The ELISA's were based on the use of

  14. Love Wave Sensor for Prostate-Specific Membrane Antigen Detection Based on Hydrophilic Molecularly-Imprinted Polymer

    Directory of Open Access Journals (Sweden)

    Pingping Tang

    2018-05-01

    Full Text Available Prostate-specific membrane antigen (PSMA is a biomarker for prostate cancer (PCa, and a specific and reliable detection technique of PSMA is urgently required for PCa early diagnosis. A Love wave sensor has been widely studied for real-time sensing and highly sensitive applications, but the sensing unit needs special handling for selective detection purpose. In this study, we prepared a versatile Love wave sensor functionalized with molecularly-imprinted polymers (MIP, PSMA as the template molecule. To enhance the specific template bindings of MIP in pure aqueous solutions, facile reversible addition/fragmentation chain transfer (RAFT precipitation polymerization (RAFTPP was used to produce surface hydrophilic polymer brushes on MIP. The presence of hydrophilic polymer brushes on MIP improved its surface hydrophilicity and significantly reduced their hydrophobic interactions with template molecules in pure aqueous media. In detection process, the acoustic delay-line is confederative to a microfluidic chip and inserted in an oscillation loop. The real-time resonance frequency of the MIP-based Love wave sensor to different concentrations of PSMA was investigated. The limit of detection (LOD for this Love SAW sensor was 0.013 ng mL−1, which demonstrates that this sensor has outstanding performance in terms of the level of detection.

  15. Radon detection system, design, test and performance

    International Nuclear Information System (INIS)

    Balcazar, M.; Chavez, A.; Pina-Villalpando, G.; Navarrete, M.

    1999-01-01

    A portable radon detection system (α-Inin) has been designed and constructed for using it in adverse environmental conditions where humidity, temperature and chemical vaporous are present. The minimum integration time is in periods of 15 min during 41 days. A 12 V battery and a photovoltaic module allow the α-Inin autonomy in field measurements. Data is collected by means of a laptop computer where data processing and α-Inin programming are carried out. α-Inin performance was simultaneously tested in a controlled radon chamber, together with a commercial α-Meter

  16. Using a genomic assay for the detection of SNPs of Knops blood group antigens leads to the identification of two caucasians homozygous for the SNP associated with the knops SL3 antigen

    DEFF Research Database (Denmark)

    Jakobsen, M. A.; Sprogoe, U.

    2015-01-01

    designed a genomic assay based on sequencing targeting the SNPs underlying the antigens of the Knops system. Study Design/Methods: Samples from a total of 105 blood donors and 2 patients were examined for polymorphisms in CR1 exon 29 by using PCR and subsequent Sanger sequencing. Results......Background/Case Studies: The antigens of the Knops (Kn) blood group system are associated with SNPs located on exon 29 and (to lesser extent) on exon 26 of the complement receptor 1 (CR1) gene. Because of a lack of proper typing antibodies, serologic detection of Kn antigens is not feasible. We....../Findings: With regard to Kn a and b antigens, we found SNP frequencies to be 90.5% for G/G (4681)* associated with Kn(a+b-) and 9.5% for G/A associated with Kn(a+b+). None of the 107 patients/donors were found to be homozygous for A/A associated with Kn(ab+). The frequencies of SNPs associated with the KCAM antigen...

  17. Detection rate of prostate cancer using prostate specific antigen in patients presenting with lower urinary tract symptoms: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chavan P

    2009-01-01

    Full Text Available Background: Need for undertaking prostate biopsies for detection of prostate cancer is often decided on the basis of serum levels of prostate specific antigen (PSA. Aim: To evaluate the case detection rate of prostate cancer among patients presenting with lower urinary tract symptoms (LUTS on the basis of PSA levels and to assess the scope of prostate biopsy in these patients. Setting and Design: A retrospective study from a tertiary care center. Materials and Methods: The clinical and histopathological data of 922 patients presenting with LUTS in the last five years was obtained from the medical record section. They had been screened for prostate cancer using PSA and /or digital rectal examination examination followed by confirmation with prostate biopsy. Statistical Analysis Used: Detection rate and receiver operating characteristic curve were performed using SPSS 16 and Medcalc softwares. Results: The detection rate of prostate cancer according to the PSA levels was 0.6%, 2.3%, 2.5%, 34.1% and 54.9% in the PSA range of 0-4, 4-10, 10-20, 20-50 and> 50 ng/ml, respectively. Maximum prostate cancer cases were detected beyond a PSA value of 20 ng/ml whereas no significant difference in the detection rate was observed in the PSA range of 0-4, 4-10 and 10-20 ng/ml. Conclusion: A low detection rate of prostate cancer observed in the PSA range of 4-20 ng/ml in LUTS patients indicates the need for use of higher cutoff values of PSA in such cases. Therefore we recommend a cutoff of 20 ng/ml of PSA for evaluation of detection rate of prostate cancer among patients presenting with LUTS.

  18. Development of a radioimmunoassay for a high molecular mass tubular antigen in urine - its application for early detection of tubular damage

    International Nuclear Information System (INIS)

    Sachse, H.J.; Falkenberg, F.W.; Scherberich, J.E.; Stefanescu, T.; Fassbinder, W.; Mondorf, A.W.; Schoeppe, W.

    1981-01-01

    In order to isolate urinary kidney antigens, the gammaglobulin fraction of an antiserum against human kidney cortex plasma membranes was coupled to Sepharose 4B. By immunospecific affinity chromatography an antigen fraction was obtained from the urine of a patient suffering from severe kidney disease. After gel filtration, the main fraction, eluted with the exclusion volume of a Sephadex G-200 column and enriched 16000-fold, was labelled with 131 I and used in a radioimmunoassay system. Soluble kidney antigens, presumably of proximal tubular origin, could be detected and quantified by the assay system in urine samples of patients with various diseases. The samples did not need to be treated, either concentrated or dialyzed, before application. The results of the experiments show a correlation between antigen excretion and kidney damage. Rejection episodes in patients with kidney transplants could be recognized early by enhanced antigen excretion. Potentially nephrotoxic drugs caused antigen excretion as well. In normal, healthy subjects output of the antigen was very low. The assay system might be of value for monitoring renal diseases. (Auth.)

  19. Horseradish peroxidase functionalized gold nanorods as a label for sensitive electrochemical detection of alpha-fetoprotein antigen.

    Science.gov (United States)

    Guo, Jinjin; Han, Xiaowei; Wang, Junchun; Zhao, Junqing; Guo, Zilin; Zhang, Yuzhong

    2015-12-15

    In this study, a novel tracer, horseradish peroxidase (HRP) functionalized gold nanorods (Au NRs) nanocomposites (HRP-Au NRs), was designed to label the signal antibodies for sensitive electrochemical measurement of alpha-fetoprotein (AFP). The preparation of HRP-Au NRs nanocomposites and the labeling of secondary antibody (Ab2) were performed by one-pot assembly of HRP and Ab2 on the surface of Au NRs. The immunosensor was fabricated by assembling carbon nanotubes (CNTs), Au NRs, and capture antibodies (Ab1) on the glassy carbon electrode. In the presence of AFP antigen, the labels were captured on the surface of the Au NRs/CNTs via specific recognition of antigen-antibody, resulting in the signal intensity being clearly increased. Differential pulse voltammetry (DPV) was employed to record the response signal of the immunosensor in phosphate-buffered saline (PBS) containing hydrogen peroxide (H2O2) and 3,3',5,5'-tetramethylbenzidine (TMB). Under optimal conditions, the signal intensity was linearly related to the concentration of AFP in the range of 0.1-100 ng ml(-1), and the limit of detection was 30 pg ml(-1) (at signal/noise [S/N] = 3). Furthermore, the immunoassay method was evaluated using human serum samples, and the recovery obtained was within 99.0 and 102.7%, indicating that the immunosensor has potential clinical applications. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Detection of prostate-specific antigen with biomolecule-gated AlGaN/GaN high electron mobility transistors

    Science.gov (United States)

    Li, Jia-dong; Cheng, Jun-jie; Miao, Bin; Wei, Xiao-wei; Xie, Jie; Zhang, Jin-cheng; Zhang, Zhi-qiang; Wu, Dong-min

    2014-07-01

    In order to improve the sensitivity of AlGaN/GaN high electron mobility transistor (HEMT) biosensors, a simple biomolecule-gated AlGaN/GaN HEMT structure was designed and successfully fabricated for prostate specific antigen (PSA) detection. UV/ozone was used to oxidize the GaN surface and then a 3-aminopropyl trimethoxysilane (APTES) self-assembled monolayer was bound to the sensing region. This monolayer serves as a binding layer for attachment of the prostate specific antibody (anti-PSA). The biomolecule-gated AlGaN/GaN HEMT sensor shows a rapid and sensitive response when the target prostate-specific antigen in buffer solution was added to the antibody-immobilized sensing area. The current change showed a logarithm relationship against the PSA concentration from 0.1 pg/ml to 0.993 ng/ml. The sensitivity of 0.215% is determined for 0.1 pg/ml PSA solution. The above experimental result of the biomolecule-gated AlGaN/GaN HEMT biosensor suggested that this biosensor might be a useful tool for prostate cancer screening.

  1. Detection of prostate-specific antigen with biomolecule-gated AlGaN/GaN high electron mobility transistors

    International Nuclear Information System (INIS)

    Li, Jia-dong; Miao, Bin; Wei, Xiao-wei; Xie, Jie; Wu, Dong-min; Cheng, Jun-jie; Zhang, Jin-cheng; Zhang, Zhi-qiang

    2014-01-01

    In order to improve the sensitivity of AlGaN/GaN high electron mobility transistor (HEMT) biosensors, a simple biomolecule-gated AlGaN/GaN HEMT structure was designed and successfully fabricated for prostate specific antigen (PSA) detection. UV/ozone was used to oxidize the GaN surface and then a 3-aminopropyl trimethoxysilane (APTES) self-assembled monolayer was bound to the sensing region. This monolayer serves as a binding layer for attachment of the prostate specific antibody (anti-PSA). The biomolecule-gated AlGaN/GaN HEMT sensor shows a rapid and sensitive response when the target prostate-specific antigen in buffer solution was added to the antibody-immobilized sensing area. The current change showed a logarithm relationship against the PSA concentration from 0.1 pg/ml to 0.993 ng/ml. The sensitivity of 0.215% is determined for 0.1 pg/ml PSA solution. The above experimental result of the biomolecule-gated AlGaN/GaN HEMT biosensor suggested that this biosensor might be a useful tool for prostate cancer screening. (paper)

  2. Assay of anti-HBs antibodies using a recombinant antigen and latex particle counting: comparison with five commercial tests.

    Science.gov (United States)

    Galanti, L M; Cornu, C; Masson, P L; Robert, A R; Becheanu, D; Lamy, M E; Cambiaso, C L

    1991-05-01

    An assay of anti-HBs antibodies based on agglutination of latex particles coated with recombinant HBs-antigen was compared with Abbott radioimmunoassay (Abbott-RIA), which uses a human plasma-derived antigen. The population examined consisted of 76 Abbott-RIA anti-HBs-negative prevaccinated subjects and 1044 serum samples anti-HBs found positive by Abbott-RIA, including 283 samples of subjects vaccinated either with a human plasma-derived vaccine (group A; n = 180) or with a recombinant vaccine (group B; n = 103). Correlation coefficients between the two techniques were respectively r = 0.89 for the whole population (n = 1044), r = 0.98 in group A and r = 0.74 in group B. Anti-HBs titres were higher with latex than with RIA in group B as shown by the regression slopes: latex = 508 + 1.11 RIA in group A and latex = -1138 + 3.97 RIA in group B, suggesting that some vaccinated subjects from group B produced antibodies against epitopes proper to the recombinant antigen. In the prevaccinated population and in group A, the latex results were compared with those of radioimmunoassays (Abbott, Sorin) and enzyme immunoassays (Behring, Roche, Pasteur). Only the Roche-EIA detected anti-HBs in the prevaccinated subjects. The correlation between the various immunoassays was r greater than 0.96 only for values higher than 100 IU/l.

  3. Improved detection of equine antibodies against Sarcocystis neurona using polyvalent ELISAs based on the parasite SnSAG surface antigens.

    Science.gov (United States)

    Yeargan, Michelle R; Howe, Daniel K

    2011-02-28

    Equine protozoal myeloencephalitis (EPM) is a common neurologic disease of horses that is caused by the apicomplexan pathogen Sarcocystis neurona. To help improve serologic diagnosis of S. neurona infection, we have modified existing enzyme-linked immunosorbent assays (ELISAs) based on the immunogenic parasite surface antigens SnSAG2, SnSAG3, and SnSAG4 to make the assays polyvalent, thereby circumventing difficulties associated with parasite antigenic variants and diversity in equine immune responses. Two approaches were utilized to achieve polyvalence: (1) mixtures of the individual recombinant SnSAGs (rSnSAGs) were included in single ELISAs; (2) a collection of unique SnSAG chimeras that fused protein domains from different SnSAG surface antigens into a single recombinant protein were generated for use in the ELISAs. These new assays were assessed using a defined sample set of equine sera and cerebrospinal fluids (CSFs) that had been characterized by Western blot and/or were from confirmed EPM horses. While all of the polyvalent ELISAs performed relatively well, the highest sensitivity and specificity (100%/100%) were achieved with assays containing the rSnSAG4/2 chimera (Domain 1 of SnSAG4 fused to SnSAG2) or using a mixture of rSnSAG3 and rSnSAG4. The rSnSAG4 antigen alone and the rSnSAG4/3 chimera (Domain 1 of SnSAG4 fused to Domain 2 of SnSAG3) exhibited the next best accuracy at 95.2% sensitivity and 100% specificity. Binding ratios and percent positivity (PP) ratios, determined by comparing the mean values for positive versus negative samples, showed that the most advantageous signal to noise ratios were provided by rSnSAG4 and the rSnSAG4/3 chimera. Collectively, our results imply that a polyvalent ELISA based on SnSAG4 and SnSAG3, whether as a cocktail of two proteins or as a single chimeric protein, can give optimal results in serologic testing of serum or CSF for the presence of antibodies against S. neurona. The use of polyvalent SnSAG ELISAs will

  4. Topics in this issue: cancer testes antigens, immune checkpoints, inflammation associated with ischemia-reperfusion and integrin targeting.

    Science.gov (United States)

    Bot, Adrian; Chiriva-Internati, Maurizio

    2012-10-01

    This issue of the International Reviews of Immunology is dedicated to several topics: cancer immunotherapy, and basic and translational aspects of immunity. Two reviews, one focused on breast and the other on lung cancer, highlight the need to redefine the cancer testes antigens (CTAs) as novel information regarding their expression profile and biological role emerges. Two other reviews showcase pivotal molecules that keep in check immunity at two different levels: the transcription factor autoimmune regulator (AIRE) important to negative selection of the T-cell repertoire, and CD22 that limits the antigen-initiated B-cell response. Two other articles focus on the debated role of Toll-like receptors (TLRs) and inflammation in general, in ischemia-reperfusion lesions that follow cardiovascular disorders and stroke. Last but not the least, this issue hosts a review that discusses the role and translational potential of the α4 integrin for the treatment of inflammatory bowel disease (IBD).

  5. Cross-reactivity among antigens of different air-borne fungi detected by ELISA using five monoclonal antibodies against Penicillium notatum.

    Science.gov (United States)

    Shen, H D; Lin, W L; Chen, R J; Han, S H

    1990-10-01

    Cross-reactivity among antigens of 12 genera of air-borne fungi, 13 species of Penicillium, and 5 species of Aspergillus was studied by ELISA using five monoclonal antibodies (MoAbs) against Penicillium notatum. Epitopes recognized by all the five MoAbs were susceptible to treatment of mild periodate oxidation and may therefore be associated with carbohydrates. Furthermore, our results showed that there is cross-reactivity among antigens of Penicillium, Aspergillus, and Eurotium species. By using these MoAbs, cross reactivity was not detected between antigens of Penicillium notatum and antigens of Fusarium solani, Alternaria porri, Cladosporium cladosporoides, Curvularia species, Nigrospora species, Aureobasidium pullulans, Wallemia species, Rhizopus arrhizus, and Candida albicans. Cross-reactivity among antigens of 11 species of Penicillium and 5 species of Aspergillus could be detected by ELISA using one of the five MoAbs (MoAb P15). The fact that there may be cross-reactivity among antigens of closely related fungi species should be considered in the diagnosis and treatment of mold allergic diseases.

  6. Simultaneous Detection of α-Fetoprotein and Carcinoembryonic Antigen Based on Si Nanowire Field-Effect Transistors

    Directory of Open Access Journals (Sweden)

    Kuiyu Zhu

    2015-08-01

    Full Text Available Primary hepatic carcinoma (PHC is one of the most common malignancies worldwide, resulting in death within six to 20 months. The survival rate can be improved by effective treatments when diagnosed at an early stage. The α-fetoprotein (AFP and carcinoembryonic antigen (CEA have been identified as markers that are expressed at higher levels in PHC patients. In this study, we employed silicon nanowire field-effect transistors (SiNW-FETs with polydimethylsiloxane (PDMS microfluidic channels to simultaneously detect AFP and CEA in desalted human serum. Dual-channel PDMS was first utilized for the selective modification of AFP and CEA antibodies on SiNWs, while single-channel PDMS offers faster and more sensitive detection of AFP and CEA in serum. During the SiNW modification process, 0.1% BSA was utilized to minimize nonspecific protein binding from serum. The linear dynamic ranges for the AFP and CEA detection were measured to be 500 fg/mL to 50 ng/mL and 50 fg/mL to 10 ng/mL, respectively. Our work demonstrates the promising potential of fabricated SiNW-FETs as a direct detection kit for multiple tumor markers in serum; therefore, it provides a chance for early stage diagnose and, hence, more effective treatments for PHC patients.

  7. TSOL18 Vaccine Antigen of Taenia solium: Development of Monoclonal Antibodies and Field Testing of the Vaccine in Cameroon

    Directory of Open Access Journals (Sweden)

    Assana, E.

    2010-01-01

    Full Text Available Chapter 1 reviews the literature about the immunological aspects of taeniid cestode infections and the existing vaccines against Taenia solium cysticercosis in pigs. One of the most promising vaccines is TSOL18, a protein that has been identified in the oncosphere of Taenia solium and expressed as a recombinant molecule in E. coli. Repeated experimental trials have shown that this vaccine is able to protect up to 100% of the immunised pigs against a challenge infection with T. solium. Antibodies raised by the vaccine are capable of killing the parasite in in vitro cultures and it is believed that antibody and complement mediated killing of invading parasites is the major protective immune mechanism induced by vaccination with TSOL18. The identification of the villages with a high risk of T. solium infection, which could subsequently be used in the vaccine trial, is reported in chapter 2. A survey was conducted in 150 households owning 1756 pigs in the rural areas of Mayo-Danay division in the far north region of Cameroon. A questionnaire survey was carried out to collect information on the pig farming system and to identify potential risk factors for T. solium cysticercosis infection in pigs. Blood samples were collected from 398 pigs with the aim of estimating the sero-prevalence of Taenia solium cysticercosis. The results showed that 90.7% of the pigs were free roaming during the dry season and that 42.7% of households keeping pigs in the rural areas had no latrine facility. Seventy six percent of the interviewed pig owners affirmed that the members of the household used open field defecation. ELISA for antigen and antibody detection showed an apparent prevalence of porcine cysticercosis of 24.6% and 32.2%, respectively. A Bayesian approach using the conditional dependence between the two diagnostic tests indicated that the true sero-prevalence of cysticercosis in Mayo-Danay was 26.6%. Binary logistic regression analysis indicated that the

  8. Identification of threshold prostate specific antigen levels to optimize the detection of clinically significant prostate cancer by magnetic resonance imaging/ultrasound fusion guided biopsy.

    Science.gov (United States)

    Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A

    2014-12-01

    Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases

  9. Detection of human leukocyte antigen compatibility and antibodies in liver transplantation in China

    Institute of Scientific and Technical Information of China (English)

    Xue-Qin Meng; Xuan Zhang; Jun Fan; Lin Zhou; Bing Hao; Xiao-Ming Chen; Wei-Hang Ma; Shu-Sen Zheng

    2009-01-01

    BACKGROUND: The exact roles of human leukocyte antigen (HLA) compatibility, HLA antibodies and underlying diseases in acute rejection of liver transplants are not clear. Moreover, cytomegalovirus (CMV) infection, one of the most common infections after transplantation, is related to HLA genotype and the incidence of acute rejection. METHODS: Since there are controversial reports, we analyzed the impact of HLA matching, HLA antibodies and underlying diseases in 38 liver transplant recipients in China, and assessed the association of CMV infection and HLA compatibility. RESULTS: The frequency of no HLA compatibility was high in patients without antigenemia (P=0.019). All 17 patients with HLA-A matching developed antigenemia (P0.05). In patients with acute rejection, no differences were found in the incidence of acute rejection in transplants for hepatitis B, tumors, or combined hepatitis B and tumors (P>0.05).CONCLUSIONS: There are fewer acute rejections in transplants with more HLA compatibilities. Speciifc investigations of underlying diseases and HLA typing may be necessary in liver transplantation. The mechanisms of CMV infection and HLA matching should be further studied. HLA before transplantation should be examined for the prevention of acute rejection and CMV infection.

  10. Comparative study of methods of detection of hepatitis ′B′ surface antigen (HBsAg.

    Directory of Open Access Journals (Sweden)

    Parab V

    1989-04-01

    Full Text Available The serum samples were collected from 52 patients of acute viral hepatitis and 235 hospital staff from Kasturba Hospital for Infectious Diseases. HBsAg was detected in their sera by counter-immuno-electrophoresis (CIEP, reverse passive hemogglutination (RPHA and by micro-enzyme-linked-immunosorbent assay (ELISA technique. Among the patients, HBsAg was detected in 12 cases (23% by CIEP, in 18 cases (34% by RPHA and in 23 patients (45% by ELISA. In the hospital staff, HBsAg was detected in 4 samples (1.7% by CIEP, in 8 samples (3.5% by RPHA and in 32 samples (13.5% by ELISA. Thus ELISA was found to be the most sensitive technique in detecting HBsAg.

  11. Optofluidic ring resonator sensor for sensitive label-free detection of breast cancer antigen CA15-3 in human serum

    Science.gov (United States)

    Zhu, Hongying; Dale, Paul S.; Fan, Xudong

    2009-05-01

    Breast cancer is the most frequently diagnosed malignancy in women worldwide. Because of its great impact on society, a lot of research funding has been used to develop novel detection tools for aiding breast cancer diagnosis and prognosis. In this work, we demonstrated a simple, fast, and sensitive detection of circulating breast cancer biomarker CA15-3 with opto-fluidic ring resonator (OFRR) sensors. The OFRR sensor employs a thin-walled capillary with wall thickness less than 4 μm. The circular cross section of the capillary forms the optical ring resonator, in which the light circulates in the form of whispering gallery modes (WGMs). The capillary wall is thin enough that the evanescent field of the WGM extends into the capillary core and responds to refractive index changes in the capillary core or close to its interior surface. The WGM spectral position will change when the biomolecules bind to the surface, yielding quantitative and kinetic information about the biomolecule interaction. Here, the direct immunoassay method was employed for the detection of CA15-3 antigen without any signal amplification steps. The sensor performance in both PBS buffer and human serum were investigated, respectively. The experimental detection limit was 5 units/mL in PBS buffer and 30 units/mL for CA15-3 spiked in serum, both of which satisfied clinical diagnosis requirements. The potential use of the OFRR as the point-of-care device for breast cancer detection was tested by measuring the CA15-3 level in blood samples collected from stage IV breast cancer patients and the results were compared with standard clinical test.

  12. Comparison of clinical performance of antigen basedenzyme immunoassay (EIA and major outer membrane protein (MOMP-PCR for detection of genital Chlamydia trachomatis infection

    Directory of Open Access Journals (Sweden)

    Mahmoud Nateghi Rostami

    2016-06-01

    Full Text Available Background: Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen worldwide. Early detection and treatment of C.trachomatis genital infection prevent serious reproductive complications. Objective: Performances of enzyme immunoassay (EIA and major outer membrane protein (MOMP-polymerase chain reaction (PCR for diagnosis of genital C.trachomatis infection in women were compared. Materials and Methods: In this cross sectional study a total of 518 women volunteers were included (33.67±8.3 yrs who had been referred to Gynecology clinics of Qom province, Iran, were included. Endocervical swab specimens were collected to detect lipopolysaccharide (LPS antigen in EIA and to amplify MOMP gene of C.trachomatis in PCR. Results were confirmed using ompI nested-PCR. Sensitivity, specificity, positive (PPV and negative predictive values (NPV were calculated for performance of the tests. Odds ratios were determined using binary logistic regression analysis. Results: In total, 37 (7.14% cases were positive by EIA and/or MOMP-PCR. All discrepant results were confirmed by nested-PCR. Sensitivity, specificity, PPV and NPV values of EIA were 59.46%, 100%, 100% and 96.98%, and those of MOMPPCR were 97.30%, 100%, 100%, 99.79%, respectively. Reproductive complications including 2.7% ectopic pregnancy, 5.4% stillbirth, 5.4% infertility, and 10.8% PROM were recorded. The risk of developing chlamydiosis was increased 4.8-fold in volunteers with cervicitis (p<0.05; OR 4.80; 95% CI 1.25-18.48. Conclusion: C.trachomatis infection should be regarded in women of reproductive ages especially those with cervicitis. Primary screening of women by using the low cost antigen-EIA is recommended; however, due to the low sensitivity of Ag-EIA, verification of the negative results by a DNA amplification method is needed.

  13. Comparison of clinical performance of antigen based-enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-PCR for detection of genital Chlamydia trachomatis infection.

    Science.gov (United States)

    Nateghi Rostami, Mahmoud; Hossein Rashidi, Batool; Aghsaghloo, Fatemeh; Nazari, Razieh

    2016-06-01

    Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen worldwide. Early detection and treatment of C.trachomatis genital infection prevent serious reproductive complications. Performances of enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-polymerase chain reaction (PCR) for diagnosis of genital C.trachomatis infection in women were compared. In this cross sectional study a total of 518 women volunteers were included (33.67±8.3 yrs) who had been referred to Gynecology clinics of Qom province, Iran, were included. Endocervical swab specimens were collected to detect lipopolysaccharide (LPS) antigen in EIA and to amplify MOMP gene of C.trachomatis in PCR. Results were confirmed using ompI nested-PCR. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated for performance of the tests. Odds ratios were determined using binary logistic regression analysis. In total, 37 (7.14%) cases were positive by EIA and/or MOMP-PCR. All discrepant results were confirmed by nested-PCR. Sensitivity, specificity, PPV and NPV values of EIA were 59.46%, 100%, 100% and 96.98%, and those of MOMP-PCR were 97.30%, 100%, 100%, 99.79%, respectively. Reproductive complications including 2.7% ectopic pregnancy, 5.4% stillbirth, 5.4% infertility, and 10.8% PROM were recorded. The risk of developing chlamydiosis was increased 4.8-fold in volunteers with cervicitis (p<0.05; OR 4.80; 95% CI 1.25-18.48). C.trachomatis infection should be regarded in women of reproductive ages especially those with cervicitis. Primary screening of women by using the low cost antigen-EIA is recommended; however, due to the low sensitivity of Ag-EIA, verification of the negative results by a DNA amplification method is needed.

  14. A new technique to detect antibody-antigen reaction (biological interactions) on a localized surface plasmon resonance (LSPR) based nano ripple gold chip

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, Iram, E-mail: iiram.qau@gmail.com [Department of Physics and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Widger, William, E-mail: widger@uh.edu [Department of Biology and Biochemistry and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Chu, Wei-Kan, E-mail: wkchu@uh.edu [Department of Physics and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States)

    2017-07-31

    Highlights: • The nano ripple LSPR chip has monolayer molecule-coating sensitivity and specific selectivity. • Gold nano-ripple sensing chip is a low cost, and a label-free method for detecting the antibody-antigen reaction. • The plasmonic resonance shift depends upon the concentration of the biomolecules attached on the surface of the nano ripple pattern. - Abstract: We demonstrate that the gold nano-ripple localized surface plasmon resonance (LSPR) chip is a low cost and a label-free method for detecting the presence of an antigen. A uniform stable layer of an antibody was coated on the surface of a nano-ripple gold pattern chip followed by the addition of different concentrations of the antigen. A red shift was observed in the LSPR spectral peak caused by the change in the local refractive index in the vicinity of the nanostructure. The LSPR chip was fabricated using oblique gas cluster ion beam (GCIB) irradiation. The plasmon-resonance intensity of the scattered light was measured by a simple optical spectroscope. The gold nano ripple chip shows monolayer scale sensitivity and high selectivity. The LSPR substrate was used to detect antibody-antigen reaction of rabbit X-DENTT antibody and DENTT blocking peptide (antigen).

  15. Antigens of worms and eggs showed a differentiated detection of specific IgG according to the time of Schistosoma mansoni infection in mice

    Directory of Open Access Journals (Sweden)

    Rafaella Fortini Queiroz Grenfell

    2012-08-01

    Full Text Available INTRODUCTION: The correlation between the immunological assay and the antibody titer can offer a tool for the experimental analysis of different phases of the disease. METHODS: Two simple immunological assays for Schistosoma mansoni in mice sera samples based on specific IgG detection for worms soluble antigens and eggs soluble antigens were standardized and evaluated in our laboratory. Fifty mice were used in negative and positive groups and the results obtained by enzyme-linked immunosorbent assays (ELISA assays were compared with the number of worms counted and the IgG titers at different times of infection. RESULTS: Data showed that ELISA using adult worm antigens (ELISA-SWAP presented a satisfactory correlation between the absorbance value of IgG titers and the individual number of worms counted after perfusion technique (R²=0.62. In addition, ELISA-SWAP differentially detected positive samples with 30 and 60 days post infection (p=0.011 and 0.003, respectively, whereas ELISA using egg antigens (ELISA-SEA detected samples after 140 days (p=0.03. CONCLUSIONS: These data show that the use of different antigens in immunological methods can be used as potential tools for the analysis of the chronological evolution of S. mansoni infection in murine schistosomiasis. Correlations with human schistosomiasis are discussed.

  16. Detection of antibody against antigen expressed by molecularly cloned hepatitis C virus cDNA: Application to diagnosis and blood screening for posttransfusion hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Miyamura, Tatsuo; Saito, Izumu (National Institute of Health, Tokyo (Japan)); Katayama, Tohru (Tokyo National Chest Hospital (Japan)); Kikuchi, Shu; Tateda, Akira (Sendai National Hospital (Japan)); Houghton, M.; Choo, Quilim; Kuo, G. (Chiron Corporation, Emeryville, CA (USA))

    1990-02-01

    A cDNA clone has been derived from the plasma of a chimpanzee with chronic non-A, non-B viral hepatits (NANBH). The authors have assayed for antibodies reacting with the encoded antigen in sera from posttransfusion hepatitis patients (643 samples from 23 patients) and their corresponding donors collected during the past 10 years in Japan. The antibody was detected in 15 out of 17 (88.2%) posttransfusion NANBH (PT-NANBH) patients whose sera over time displayed multiple alanine aminotransferase (ALT) peaks. In general, the antibody was detected after several peaks of serum ALT elevations and, once detected, it persisted for years. Of the 15 well-defined cases of PT-NANBH that showed multiple ALT peaks and hepatitis C virus seroconversions, 11 (73.3%) were shown to be transfused with at least one unit of blood positive for the antibody. The retrospective analysis showed that all tested donor blood found to be positive for the antibody had been transfused to recipients who afterwards developed NANBH. These data strongly suggest that the cloned cDNA originated from an etiological agent of NANBH termed the hepatitis C virus. Furthermore, the present study demonstrates that had the screening been done with the anti-hepatitis C virus assay, 11 out of 17 (64.7%) cases of chronic PT-NANBH and 1 out of 6 (16.6%) acute PT-NANBH would have been prevented.

  17. Detection of antibody against antigen expressed by molecularly cloned hepatitis C virus cDNA: Application to diagnosis and blood screening for posttransfusion hepatitis

    International Nuclear Information System (INIS)

    Miyamura, Tatsuo; Saito, Izumu; Katayama, Tohru; Kikuchi, Shu; Tateda, Akira; Houghton, M.; Choo, Quilim; Kuo, G.

    1990-01-01

    A cDNA clone has been derived from the plasma of a chimpanzee with chronic non-A, non-B viral hepatits (NANBH). The authors have assayed for antibodies reacting with the encoded antigen in sera from posttransfusion hepatitis patients (643 samples from 23 patients) and their corresponding donors collected during the past 10 years in Japan. The antibody was detected in 15 out of 17 (88.2%) posttransfusion NANBH (PT-NANBH) patients whose sera over time displayed multiple alanine aminotransferase (ALT) peaks. In general, the antibody was detected after several peaks of serum ALT elevations and, once detected, it persisted for years. Of the 15 well-defined cases of PT-NANBH that showed multiple ALT peaks and hepatitis C virus seroconversions, 11 (73.3%) were shown to be transfused with at least one unit of blood positive for the antibody. The retrospective analysis showed that all tested donor blood found to be positive for the antibody had been transfused to recipients who afterwards developed NANBH. These data strongly suggest that the cloned cDNA originated from an etiological agent of NANBH termed the hepatitis C virus. Furthermore, the present study demonstrates that had the screening been done with the anti-hepatitis C virus assay, 11 out of 17 (64.7%) cases of chronic PT-NANBH and 1 out of 6 (16.6%) acute PT-NANBH would have been prevented

  18. An ultrasensitive electrochemical immunosensor for the detection of prostate-specific antigen based on conductivity nanocomposite with halloysite nanotubes.

    Science.gov (United States)

    Li, Yueyuan; Khan, Malik Saddam; Tian, Lihui; Liu, Li; Hu, Lihua; Fan, Dawei; Cao, Wei; Wei, Qin

    2017-05-01

    A sensitive label-free amperometric electrochemical immunosensor for detection of prostate-specific antigen (PSA) was proposed in this work. The nanocomposite of halloysite nanotubes with polypyrrole shell and palladium nanoparticles (HNTs@PPy-Pd) was used as a novel signal label. The HNTs with adequate hydroxyl groups are economically available raw materials. PPy, as an electrically conducting polymer material, can be absorbed to the surface of HNTs by in situ oxidative polymerization of the pyrrole monomer and form a shell on the HNTs. The shell of PPy could not only improve the conductivity of the nanocomposite but also absorb large amounts of Pd nanoparticles (NPs). The Pd NPs with high electrocatalytic activity toward the reduction of H 2 O 2 and the HNTs@PPy-Pd nanocomposite as the analytical signal label could improve the sensitivity of the immunosensor. Under optimal conditions, the immunosensor showed a low detection limit (0.03 pg/mL) and a wide linear range (0.0001 to 25 ng/mL) of PSA. Moreover, its merits such as good selectivity, acceptable reproducibility, and stability indicate that the fabricated immunosensor has a promising application potential in clinical diagnosis. Graphical Abstract A new label-free amperometric electrochemical immunosensor based on HNTs@PPy-Pd nanocomposite for quantitative detection of PSA.

  19. Polyhydroquinone-graphene composite as new redox species for sensitive electrochemical detection of cytokeratins antigen 21-1

    Science.gov (United States)

    Wang, Huiqiang; Rong, Qinfeng; Ma, Zhanfang

    2016-07-01

    Polyhydroquinone-graphene composite as a new redox species was synthesized simply by a microwave-assisted one-pot method through oxidative polymerization of hydroquinone by graphene oxide, which exhibited excellent electrochemical redox activity at 0.124 V and can remarkably promote electron transfer. The as-prepared composite was used as immunosensing substrate in a label-free electrochemical immunosensor for the detection of cytokeratins antigen 21-1, a kind of biomarker of lung cancer. The proposed immunosensor showed wide liner range from 10 pg mL-1 to 200 ng mL-1 with a detection limit 2.3 pg mL-1, and displayed a good stability and selectivity. In addition, this method has been used for the analysis of human serum sample, and the detection results showed good consistence with those of ELISA. The present substrate can be easily extended to other polymer-based nanocomposites.

  20. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  1. Detection of NP, N3 and N7 antibodies to avian influenza virus by indirect ELISA using yeast-expressed antigens

    Directory of Open Access Journals (Sweden)

    Ammayappan Arun

    2009-10-01

    Full Text Available Abstract Background Avian influenza viruses, belonging to the family Orthomyxoviridae, possess distinct combinations of hemagglutinin (H and the neuraminidase (N surface glycoproteins. Typing of both H and N antigens is essential for the epidemiological and surveillance studies. Therefore, it is important to find a rapid, sensitive, and specific method for their assay, and ELISA can be useful for this purpose, by using recombinant proteins. Results The nucleoprotein (NP and truncated neuraminidase subtype 3 and 7 of avian influenza virus (AIV were expressed in Saccharomyces cerevisiae and used to develop an indirect enzyme-linked immunosorbent assay for antibody detection. The developed assays were evaluated with a panel of 64 chicken serum samples. The performance of NP-ELISA was compared with the commercially available ProFlok® AIV ELISA kit. The results showed comparable agreement and sensitivity between the two tests, indicating that NP-ELISA assay can be used for screening the influenza type A antibody in AIV infected birds. The N3 and N7- ELISAs also reacted specifically to their type specific sera and did not exhibit any cross-reaction with heterologous neuraminidase subtype specific sera. Conclusion The study demonstrates the expression of the NP, N3, and N7 proteins of AIV in yeast (S. cerevisiae and their application in developing an indirect ELISA for detecting NP, N3 and N7 antibodies from AIV-infected chicken sera. The described indirect ELISAs are rapid, sensitive, specific and can be used as promising tests during serological surveillance.

  2. Evaluation of monoclonal antibody-based sandwich direct ELISA (MSD-ELISA for antigen detection of foot-and-mouth disease virus using clinical samples.

    Directory of Open Access Journals (Sweden)

    Kazuki Morioka

    Full Text Available A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA method was previously developed for foot-and-mouth disease (FMD viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01. In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01. Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.

  3. Evaluation of monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) for antigen detection of foot-and-mouth disease virus using clinical samples.

    Science.gov (United States)

    Morioka, Kazuki; Fukai, Katsuhiko; Sakamoto, Kenichi; Yoshida, Kazuo; Kanno, Toru

    2014-01-01

    A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) method was previously developed for foot-and-mouth disease (FMD) viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS)-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01). In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01). Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.

  4. Fluorescent QDs-polystyrene composite nanospheres for highly efficient and rapid protein antigen detection

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Changhua; Mao, Mao [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China); Yuan, Hang [Tsinghua University, Life Science Division, Graduate School at Shenzhen (China); Shen, Huaibin [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China); Wu, Feng; Ma, Lan, E-mail: malan@sz.tsinghua.edu.cn [Tsinghua University, Life Science Division, Graduate School at Shenzhen (China); Li, Lin Song, E-mail: lsli@henu.edu.cn [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China)

    2013-09-15

    In this paper, high-quality carboxyl-functionalized fluorescent (red, green, and blue emitting) nanospheres (46-103 nm) consisting of hydrophobic quantum dots (QDs) and polystyrene were prepared by a miniemulsion polymerization approach. This miniemulsion polymerization approach induced a homogeneous distribution and high aqueous-phase transport efficiency of fluorescent QDs in composite nanospheres, which proved the success of our encoding QDs strategy. The obtained fluorescent nanospheres exhibited high stability in aqueous solution under a wide range of pH, different salt concentrations, PBS buffer, and thermal treatment at 80 Degree-Sign C. Based on the red emitting composite nanosphere, we performed fluorescent lateral flow immunoassay (LFIA) strips for high-sensitivity and rapid alpha-fetal protein detection. The detection limit reached 0.1 ng/mL, which was 200 times higher than commercial colloidal gold-labeled LFIA strips, and it reached similar detection level in enzyme-linked immunosorbent assay kit.

  5. Evaluation of detection methodology for carcinoembryonic antigen and application of CEA in diagnosis of gastric cancer

    International Nuclear Information System (INIS)

    Wang Enlan; Li Tao

    2005-01-01

    To compare the specificity and sensitivity of different methods in detection of CEA, and to investigate the application of CEA detection in diagnosis of gastric cancer, CEA in serum of 36 patients with gastric cancer and 20 negtive reference serum was detected by ELISA, TR- FIA, RIA and CLIA. The results showed that the specificity of these 4 methods was all 100% and the sensitivity of ELISA was the lowest (19.4%) while CLIA was the highest (44.4%). Therefore, the sensitivity of ELISA should be raised and CEA, besides used as an observation index for curative effects in a part of gastric cancer patients, can not be used in diagnosis of gastric cancer. (authors)

  6. DETECTION OF HUMAN ANTI-ZIKA VIRUS IgG BY ELISA USING AN ANTIGEN FROM in vitro INFECTED VERO CELLS: PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    Laura Masami SUMITA

    Full Text Available SUMMARY Zika virus (ZKV infection is a huge public health problem in Brazil because of the increased incidence of microcephaly in neonates from infected mothers. Detection of specific IgG antibodies in maternal serum samples constitutes an important approach for diagnosing ZKV infection and evaluating its relationship with neonatal microcephaly. However, as there is no serological test produced in Brazil to detect IgM and IgG antibodies against ZKV, we sought to examine specific IgG in serum samples from patients or suspected mothers to detect previous infection and to test for specificity with regard to flaviviral infections occurring in the same area. Brazilian Zika virus native antigens were obtained from infected Vero cell layers or free virions in the culture medium and then used in ELISA. We tested sera from eight ZKV RNA-diagnosed infected patients (ZKVR, seven neonates with microcephaly and their mothers after delivery (MM, 140 dengue virus IgM-positive (DM and IgG (DG-positive patients, and 100 yellow fever (YF-vaccinated patients. According to the ELISA, ZKVR samples were mostly positive (7/8, and all the MM serum samples were positive for ZKV IgG (7/7. In contrast, cross-reactions for dengue or yellow fever-vaccinated patients were observed, including DM (48/95, DG (10/45 or YF (3/100 serum samples; however, these cross-reactions exhibited low antigen avidity so that 6 M urea largely removed this cross-reactivity, with only a few cross-reacting samples remaining (8/140. ELISA based on extracted virions was much more specific, with all ZKVR (8/8 and MM sera being positive for ZKV IgG (7/7 and only borderline cross-reactivity found for DM (6/95, DG (3/45 or YF (4/100-vaccinated serum samples. This technique (ELISA can identify specific IgG in ZKV-infected patients and may be helpful in diagnosing congenital infetions after maternal RNA virus clearance or in epidemiological studies.

  7. Detection of a nuclear, EBNA-type antigen in apparently EBNA-negative Herpesvirus papio (HVP)-transformed lymphoid lines by the acid-fixed nuclear binding technique.

    Science.gov (United States)

    Ohno, S; Luka, J; Falk, L; Klein, G

    1977-12-15

    In agreement with the findings of previous authors, we could not detect a virally determined nuclear antigen in Herpesvirus papio (HVP)-transformed baboon lymphoid lines by anticomplementary staining in situ, as for EBNA. However, by means of our recently developed acid-fixed nuclear binding technique an EBNA-like antigen could be readily demonstrated, after extraction from both producer and non-producer lines. We propose to designate the antigen as HUPNA. It can be detected by a human anti-EBNA antibody, suggesting cross-reactivity, if not identity, between EBNA and HUPNA. HVP-DNA carrying non-producer lines, negative for in situ ACIF stainability but capable of yielding HUPNA by the nuclear binding technique, can be superinfected with EBV, with brilliant EBNA expression as the result, suggesting that the defective in situ staining is a property associated with the baboon HVP, rather than the baboon lymphoid cell per se.

  8. A study on the prevalence of dog erythrocyte antigen 1.1 and detection of canine Babesia by polymerase chain reaction from apparently healthy dogs in a selected rural community in Zimbabwe

    Directory of Open Access Journals (Sweden)

    Solomon Dhliwayo

    2016-10-01

    Full Text Available A study was carried out to determine the prevalence of blood group antigen dog erythrocyte antigen (DEA 1.1 in mixed breed dogs in rural Chinamhora, Zimbabwe. DEA 1.1 is clinically the most important canine blood group as it is the most antigenic blood type; hence, DEA 1.1 antibodies are capable of causing acute haemolytic, potentially life-threatening transfusion reactions. In this study, blood samples were collected from 100 dogs in Chinamhora, and blood typing was carried out using standardised DEA 1.1 typing strips with monoclonal anti–DEA 1.1 antibodies (Alvedia® LAB DEA 1.1 test kits. Polymerase chain reaction for detecting Babesia spp. antigen was carried out on 58 of the samples. Of the 100 dogs, 78% were DEA 1.1 positive and 22% were DEA 1.1 negative. A significantly (p = 0.02 higher proportion of females (90.5% were DEA 1.1 positive than males (69.0%. The probability of sensitisation of recipient dogs following first-time transfusion of untyped or unmatched blood was 17.2%, and an approximately 3% (2.95% probability of an acute haemolytic reaction following a second incompatible transfusion was found. Babesia spp. antigen was found in 6.9% of the samples. No significant relationship (χ2 = 0.56, p = 0.45 was found between DEA 1.1 positivity and Babesia spp. antigen presence. Despite a low probability of haemolysis after a second incompatibility transfusion, the risk remains present and should not be ignored. Hence, where possible, blood typing for DEA 1.1 is recommended. A survey of DEA 3, 4, 5 and 7 in various breeds is also recommended.

  9. STANDARDIZATION OF PROCEDURES OF Plasmodium falciparum ANTIGEN PREPARATION FOR SEROLOGIC TESTS

    Directory of Open Access Journals (Sweden)

    Sandra L.M. AVILA

    1998-09-01

    Full Text Available The objective of the present study is to standardize the technical variables for preparation and storage of Plasmodium falciparum and of antigen components extracted with the amphoteric detergent Zwittergent. P. falciparum obtained from in vitro culture was stored at different temperatures and for different periods of time. For each variable, antigen components of the parasite were extracted in the presence or absence of protease inhibitors and submitted or not to later dialysis. Products were stored for 15, 30 and 60 days at different temperatures and immunological activity of each extract was determined by SDS-PAGE and ELISA using positive or negative standard sera for the presence of IgG directed to blood stage antigens of P. falciparum. Antigen extracts obtained from parasites stored at -20oC up to 10 days or at -70oC for 2 months presented the best results, showing well-defined bands on SDS-PAGE and Western blots and presenting absorbance values in ELISA that permitted safe differentiation between positive and negative sera.O objetivo deste estudo foi padronizar variáveis técnicas para o armazenamento de Plasmodium falciparum e de seus componentes antigênicos. Sedimentos de parasitas foram obtidos do cultivo in vitro de P.falciparum e estocados em diferentes temperaturas por diferentes períodos de tempo. De cada variável, foram extraídos os componentes antigênicos com detergente anfótero Zwittergent na presença e na ausência de inibidores de proteases e submetidos ou não a posterior diálise. Os produtos foram estocados por 15, 30 e 60 dias em diferentes temperaturas e caracterizados por SDS-PAGE. A atividade antigênica de cada extrato foi determinada por ELISA e Western blotting usando soros positivos e negativos para anticorpos IgG anti-formas eritrocitárias de P.falciparum. Os extratos antigênicos obtidos de parasitas estocados até 10 dias a _20ºC ou por 2 meses a _70ºC e tratados com inibidores de proteases, sob as

  10. Detection of antigen in sera of patients with invasive aspergillosis : Intra- and interlaboratory reproducibility

    NARCIS (Netherlands)

    Verweij, PE; Erjavec, Z; Sluiters, W; Goessens, W; Rozenberg-Arska, M; Debets-Ossenkopp, YJ; Guiot, HFL; Meis, JFGM

    The intra-and interlaboratory reproducibilities of a commercial sandwich enzyme-linked immunosorbent assay (ELISA) for the detection of Aspergillus galactomannan in serum (Platelia Aspergillus; Sanofi Diagnostics Pasteur, Marnes-La-Coquette, France) were evaluated in six laboratories of university

  11. Genetic diversity of merozoite surface antigens in Babesia bovis detected from Sri Lankan cattle.

    Science.gov (United States)

    Sivakumar, Thillaiampalam; Okubo, Kazuhiro; Igarashi, Ikuo; de Silva, Weligodage Kumarawansa; Kothalawala, Hemal; Silva, Seekkuge Susil Priyantha; Vimalakumar, Singarayar Caniciyas; Meewewa, Asela Sanjeewa; Yokoyama, Naoaki

    2013-10-01

    Babesia bovis, the causative agent of severe bovine babesiosis, is endemic in Sri Lanka. The live attenuated vaccine (K-strain), which was introduced in the early 1990s, has been used to immunize cattle populations in endemic areas of the country. The present study was undertaken to determine the genetic diversity of merozoite surface antigens (MSAs) in B. bovis isolates from Sri Lankan cattle, and to compare the gene sequences obtained from such isolates against those of the K-strain. Forty-four bovine blood samples isolated from different geographical regions of Sri Lanka and judged to be B. bovis-positive by PCR screening were used to amplify MSAs (MSA-1, MSA-2c, MSA-2a1, MSA-2a2, and MSA-2b), AMA-1, and 12D3 genes from parasite DNA. Although the AMA-1 and 12D3 gene sequences were highly conserved among the Sri Lankan isolates, the MSA gene sequences from the same isolates were highly diverse. Sri Lankan MSA-1, MSA-2c, MSA-2a1, MSA-2a2, and MSA-2b sequences clustered within 5, 2, 4, 1, and 9 different clades in the gene phylograms, respectively, while the minimum similarity values among the deduced amino acid sequences of these genes were 36.8%, 68.7%, 80.3%, 100%, and 68.3%, respectively. In the phylograms, none of the Sri Lankan sequences fell within clades containing the respective K-strain sequences. Additionally, the similarity values for MSA-1 and MSA-2c were 40-61.8% and 90.9-93.2% between the Sri Lankan isolates and the K-strain, respectively, while the K-strain MSA-2a/b sequence shared 64.5-69.8%, 69.3%, and 70.5-80.3% similarities with the Sri Lankan MSA-2a1, MSA-2a2, and MSA-2b sequences, respectively. The present study has shown that genetic diversity among MSAs of Sri Lankan B. bovis isolates is very high, and that the sequences of field isolates diverged genetically from the K-strain. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Malaria prevalence defined by microscopy, antigen detection, DNA amplification and total nucleic acid amplification in a malaria-endemic region during the peak malaria transmission season.

    Science.gov (United States)

    Waitumbi, John N; Gerlach, Jay; Afonina, Irina; Anyona, Samuel B; Koros, Joseph N; Siangla, Joram; Ankoudinova, Irina; Singhal, Mitra; Watts, Kate; Polhemus, Mark E; Vermeulen, Nicolaas M; Mahoney, Walt; Steele, Matt; Domingo, Gonzalo J

    2011-07-01

    To determine the malaria prevalence by microscopy, antigen detection and nucleic acid detection in a defined subpopulation in a Plasmodium falciparum-endemic region during the peak transmission season. Blood specimens were collected in a cross-sectional study involving children aged 5-10 years (n = 195) presenting with acute fever to two clinics in Western Kenya. All specimens underwent microscopy, HRP2 and aldolase antigen detection by enzyme immunoassay (EIA), parasite-specific DNA and total nucleic acid (RNA and DNA) by real-time PCR (qPCR) and reverse-transcriptase PCR (qRT-PCR). Microscopy detected 65/195 cases of malaria infection [95% confidence interval (CI) 52-78]. HRP2 and aldolase EIA had similar sensitivity levels detecting antigen in 65/195 (95% CI, 52-78) and 57/195 (95% CI, 45-70) cases. Discordants in antigen detection vs. microscopy occurred at Detection of total nucleic acid allowed a 3 log lower limit of detection than just DNA detection by real-time PCR in vitro. In clinical specimens, 114/195 (95% CI, 100-127) were qPCR positive (DNA), and 187/195 (95% CI, 179-191) were qRT-PCR positive (DNA plus RNA). The prevalence of submicroscopic malaria infection was significantly higher when detecting total nucleic acid than just DNA in this outpatient population during the high transmission season. Defining standards for submicroscopic infection will be important for control programmes, diagnostics development efforts and molecular epidemiology studies. © 2011 Blackwell Publishing Ltd.

  13. Advantages and disadvantages of current diagnostic tests for the detection of Helicobacter pylori.

    Science.gov (United States)

    Mégraud, F

    1996-01-01

    Current tests used to detect Helicobacter pylori are either invasive (histological detection, culture, the polymerase chain reaction (PCR), smear examination) or non-invasive (serology, 13C-urea breath test). These tests vary in their sensitivity and specificity, and the choice of test will depend on the situation, for example, whether the test is to detect infection or the success of eradication treatment. The accuracy of histological tests depends, to a large degree, on the expertise of the pathologist, while the accuracy of culture can depend on the conditions in which the specimen is transported and processed. When performed under optimal conditions, both techniques give very good results. The PCR test has similar sensitivity and specificity to histological and culture tests but a strict protocol must be followed to avoid contamination with H. pylori DNA. The rapid urease test (with a reading taken 1 hour later) is suitable for diagnosis before treatment but its sensitivity decreases after treatment. Smear examination has limited sensitivity. The urea breath test and serology (specific IgG detected by enzyme-linked immunosorbent assay with purified antigens) have sensitivities close to those using the best of the biopsy methods. Other points to consider when selecting a test are its availability, the rapidity of the results (which can range from a few minutes to 2 weeks), possibilities for retrospective analysis, quantification and the detection of pathogenic properties, the globality of certain tests that present an overall picture of the stomach, thus avoiding errors in sampling, and the cost of the test. Important added value can be gained from certain tests: histology allows evaluation of the status of the mucosa, culture allows strain typing and tests for antibiotic susceptibility, and the breath test can confirm successful eradication without endoscopy. When the diagnostic tests are performed correctly, most of them are highly accurate.

  14. Two competitive enzyme immunoassays for the detection of IgG class antibodies to hepatitis a antigen

    Directory of Open Access Journals (Sweden)

    Claudia Lamarca Vitral

    1991-06-01

    Full Text Available Two competitive enzyme immunoassays (EIA techniques were developed: in the first (COMP-1, test sera were added together with HAV antigen on anti-HAV IgG-coated wells followed by an anti-HA VHRP conjugate; in the second (COMP-2, test sera and anti-HA VHRP conjugate competed for HAV epitopes previously adsorbed to anti-HA V IgG-coated wells. Both procedures used tetramethylbenzidine (TMB as a substrate. Both competitive tests were shown to be reproducible and suitable for routine diagnosis and research purposes.Foram desenvolvidos dois ensaios imunoenzimáticos (EIA competitivos: no primeiro (COMP-1 colocou-se numa placa sensibilizada com anti-HAVIgG as amostras teste juntamente como antígeno HA Vea seguir o conjugado anti-HA VHRP; no segundo (COMP-2, as amostras teste e o conjugado anti-HAV HRP competem pelos epitopos do antígeno HAV previamente absorvido na placa sensibilizada do anti-HAV IgG. O substrato utilizado foi tetrametilbenzidina (TMB. Ambas as técnicas mostraram ser produtíveis e aplicáveis para fins de diagnóstico e pesquisa.

  15. Analytical validation of a reference laboratory ELISA for the detection of feline leukemia virus p27 antigen.

    Science.gov (United States)

    Buch, Jesse S; Clark, Genevieve H; Cahill, Roberta; Thatcher, Brendon; Smith, Peter; Chandrashekar, Ramaswamy; Leutenegger, Christian M; O'Connor, Thomas P; Beall, Melissa J

    2017-09-01

    Feline leukemia virus (FeLV) is an oncogenic retrovirus of cats. Immunoassays for the p27 core protein of FeLV aid in the detection of FeLV infections. Commercial microtiter-plate ELISAs have rapid protocols and visual result interpretation, limiting their usefulness in high-throughput situations. The purpose of our study was to validate the PetChek FeLV 15 ELISA, which is designed for the reference laboratory, and incorporates sequential, orthogonal screening and confirmatory protocols. A cutoff for the screening assay was established with 100% accuracy using 309 feline samples (244 negative, 65 positive) defined by the combined results of FeLV PCR and an independent reference p27 antigen ELISA. Precision of the screening assay was measured using a panel of 3 samples (negative, low-positive, and high-positive). The intra-assay coefficient of variation (CV) was 3.9-7.9%; the inter-assay CV was 6.0-8.6%. For the confirmatory assay, the intra-assay CV was 3.0-4.7%, and the inter-assay CV was 7.4-9.7%. The analytical sensitivity for p27 antigen was 3.7 ng/mL for inactivated whole FeLV and 1.2 ng/mL for purified recombinant FeLV p27. Analytical specificity was demonstrated based on the absence of cross-reactivity to related retroviruses. No interference was observed for samples containing added bilirubin, hemoglobin, or lipids. Based on these results, the new high-throughput design of the PetChek FeLV 15 ELISA makes it suitable for use in reference laboratory settings and maintains overall analytical performance.

  16. The clinical significance of detection of serum Pre-S1 antigen

    International Nuclear Information System (INIS)

    Jiang Xuehua; Huang Zhuqing; Han Yi; Gong Shoujun

    2003-01-01

    To study the clinical significance of detection of serum Pre-S 1 Ag, the serum Pre-S 1 Ag, HBV-marks and HBV-DNA were detected in 338 patients with hepatitis B. The positive rate and the relationship between them were analyzed and compared. In 338 patients, the positive rate of serum Pre-S 1 Ag, HBeAg, HBV-DNA was 63.02%, 48.52%, 68.05% respectively, and the co-positive rate of Pre-S 1 Ag with HBV-DNA, HBeAg was 78.56%, 81.17% respectively. There was a significant correlation between Pre-S 1 Ag, HBeAg and HBV-DNA (P 1 Ag could well reflect the reproductive status of hepatitis B virus, and so it could be used as the clinical marker of the reproductive status of hepatitis B virus

  17. Electrochemical Detecting Lung Cancer-Associated Antigen Based on Graphene-Gold Nanocomposite

    Directory of Open Access Journals (Sweden)

    Zheng Wei

    2017-03-01

    Full Text Available Using a Au nanoparticle/reduced graphene oxide composite (AuNP-RGO, a signal-enhanced electrochemical immunosensor without label was created to detect neuron-specific enolase (NSE. Furthermore, an environmentally-friendly method was developed to prepare AuNP-RGO by employing chitosan (CS, which served as reducing and stabilizing agent. We showed that the sensitivity of the immunosensor designed in this report was remarkably enhanced because of the numerous active sites in the sensor provided by the AuNP-RGO nanostructure. For the quantification of NSE, the immunosensor exhibited a positive linear relationship with the concentration in the range of 0.1 to 2000 ng/mL, where the limit of the detection was 0.05 ng/mL.

  18. Detection of Clonorchis sinensis circulating antigen in sera from Chinese patients by immunomagnetic bead ELISA based on IgY.

    Directory of Open Access Journals (Sweden)

    Ge Nie

    Full Text Available BACKGROUND: Clonorchiasis, caused by Clonorchis sinensis, is widely distributed in Southeast Asia including China. Clonorchiasis is included in control programs of neglected tropical diseases by World Health Organization (WHO because it is one of the major health problems in most endemic areas. Diagnosis of clonorchiasis plays a key role in the control programs. However, so far, there is no satisfactory method for clonorchiasis because of low sensitivity, poor practicality and high false positivity of available diagnostic tools. METHODOLOGY/PRINCIPAL FINDINGS: We developed an immunomagnetic bead enzyme-linked immunosorbent assay (ELISA based on IgY (egg yolk immunoglobulin against cysteine proteinase of C. sinensis for detection of circulating antigen in serum samples of patients infected with C. sinensis. The polyclonal IgY, coated with magnetic beads, was used as a capture antibody and a monoclonal IgG labeled with horseradish peroxidase as a detection antibody in the IgY-based immunomagnetic bead ELISA system (IgY-IMB-ELISA. The results showed that the sensitivity of IgY-IMB-ELISA was 93.3% (14 of 15 in cases of heavy infection (5000 to 9999 eggs per gram feces, i.e, EPG 5000-9999, 86.7% (13 of 15 in cases of moderate infection (EPG 1000-4999 and 75.0% (9 of 12 in cases of light infection (EPG <1000 of clonorchiasis. Together 36 of total 42 (85.7% serum samples of human clonorchiasis gave a positive reaction. There was a significant correlation between ELISA optical density and egg counts (EPG with a correlation coefficient of 0.83 in total 42 patients. There were no positive results in patients with trichinosis (n = 10 or cysticercosis (n = 10. Cross-reactivity was 6.7% (2 of 30 with schistosomiasis japonica and 10.0% (3 of 30 with paragonimiasis, respectively. No positive reaction was found in 20 healthy persons. CONCLUSIONS: Our findings suggest that IgY-IMB-ELISA appears to be a sensitive and specific assay for detection of circulating

  19. Detection of Clonorchis sinensis circulating antigen in sera from Chinese patients by immunomagnetic bead ELISA based on IgY.

    Science.gov (United States)

    Nie, Ge; Wang, Ting; Lu, Shengjun; Liu, Wenqi; Li, Yonglong; Lei, Jiahui

    2014-01-01

    Clonorchiasis, caused by Clonorchis sinensis, is widely distributed in Southeast Asia including China. Clonorchiasis is included in control programs of neglected tropical diseases by World Health Organization (WHO) because it is one of the major health problems in most endemic areas. Diagnosis of clonorchiasis plays a key role in the control programs. However, so far, there is no satisfactory method for clonorchiasis because of low sensitivity, poor practicality and high false positivity of available diagnostic tools. We developed an immunomagnetic bead enzyme-linked immunosorbent assay (ELISA) based on IgY (egg yolk immunoglobulin) against cysteine proteinase of C. sinensis for detection of circulating antigen in serum samples of patients infected with C. sinensis. The polyclonal IgY, coated with magnetic beads, was used as a capture antibody and a monoclonal IgG labeled with horseradish peroxidase as a detection antibody in the IgY-based immunomagnetic bead ELISA system (IgY-IMB-ELISA). The results showed that the sensitivity of IgY-IMB-ELISA was 93.3% (14 of 15) in cases of heavy infection (5000 to 9999 eggs per gram feces, i.e, EPG 5000-9999), 86.7% (13 of 15) in cases of moderate infection (EPG 1000-4999) and 75.0% (9 of 12) in cases of light infection (EPG <1000) of clonorchiasis. Together 36 of total 42 (85.7%) serum samples of human clonorchiasis gave a positive reaction. There was a significant correlation between ELISA optical density and egg counts (EPG) with a correlation coefficient of 0.83 in total 42 patients. There were no positive results in patients with trichinosis (n = 10) or cysticercosis (n = 10). Cross-reactivity was 6.7% (2 of 30) with schistosomiasis japonica and 10.0% (3 of 30) with paragonimiasis, respectively. No positive reaction was found in 20 healthy persons. Our findings suggest that IgY-IMB-ELISA appears to be a sensitive and specific assay for detection of circulating antigen in human clonorchiasis.

  20. Development of a Nucleoprotein-Based Enzyme-Linked Immunosorbent Assay Using a Synthetic Peptide Antigen for Detection of Avian Metapneumovirus Antibodies in Turkey Sera

    Science.gov (United States)

    Alvarez, Rene; Njenga, M. Kariuki; Scott, Melissa; Seal, Bruce S.

    2004-01-01

    Avian metapneumoviruses (aMPV) cause an upper respiratory tract disease with low mortality but high morbidity, primarily in commercial turkeys, that can be exacerbated by secondary infections. There are three types of aMPV, of which type C is found only in the United States. The aMPV nucleoprotein (N) amino acid sequences of serotypes A, B, and C were aligned for comparative analysis. On the basis of the predicted antigenicity of consensus sequences, five aMPV-specific N peptides were synthesized for development of a peptide antigen enzyme-linked immunosorbent assay (aMPV N peptide-based ELISA) to detect aMPV-specific antibodies among turkeys. Sera from naturally and experimentally infected turkeys were used to demonstrate the presence of antibodies reactive to the chemically synthesized aMPV N peptides. Subsequently, aMPV N peptide 1, which had the sequence 10-DLSYKHAILKESQYTIKRDV-29, with variations at only three amino acids among aMPV serotypes, was evaluated as a universal aMPV ELISA antigen. Data obtained with the peptide-based ELISA correlated positively with total aMPV viral antigen-based ELISAs, and the peptide ELISA provided higher optical density readings. The results indicated that aMPV N peptide 1 can be used as a universal ELISA antigen to detect antibodies for all aMPV serotypes. PMID:15013970

  1. Immunochromatographic antigen testing alone is sufficient to identify asymptomatic refugees at risk of severe malaria presenting to a single health service in Victoria.

    Science.gov (United States)

    Fedele, Pasquale L; Wheeler, Michael; Lemoh, Christopher; Chunilal, Sanjeev

    2014-10-01

    Current screening guidelines for malaria in new refugees include a combination of thick and thin film examination and immunochromatographic antigen test (ICT). However, as the prevalence of malaria in our population has decreased due to changing refugee demographics, we sought to determine if an ICT alone can reliably exclude malaria in our asymptomatic refugee population.A retrospective analysis was conducted of all investigations for malaria performed from 1 August 2011 to 31 July 2013, including thick and thin blood film examination, BinaxNOW ICT, and external morphological and polymerase chain reaction (PCR) validation where applicable.Malaria was diagnosed in 45 of 1248 (3.6%) patients investigated, all of whom were symptomatic and the majority (71.1%) returned travellers. All 599 asymptomatic refugees screened were negative. Overall, 42 of 45 malaria cases were detected by the ICT; sensitivity 93.3% (95% CI 80.7-98.3%) and negative predictive value (NPV) 99.8% (99.2-99.9%). All 21 cases of Plasmodium falciparum and 20 of 22 cases of Plasmodium vivax were detected, giving a sensitivity of 100% (80.8-100%) and 90.9% (69.4-98.4%) respectively. Too few cases of Plasmodium malariae and no cases of Plasmodium ovale or Plasmodium knowlesi were diagnosed for adequate assessment to be carried out.These data suggest that full malaria screening in all asymptomatic refugees with the combination of thick and thin blood films and rapid antigen test may not be warranted. Alternative screening approaches should be considered, including the use of ICT alone, or limiting screening of asymptomatic refugees to only those originating from countries with high incidence of malaria.

  2. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer

    International Nuclear Information System (INIS)

    Bates, Anthony; Miles, Kenneth

    2017-01-01

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at <5%. Eighty-eight T2-weighted images in 18 patients demonstrated abnormal PSMA expression within the TZ on PET-MR. 123 images were PSMA negative. Based on the corrected p-value of 0.005, significant differences between PSMA positive and negative slices were found for 16 texture parameters: Standard deviation and mean of positive pixels for all spatial filters (p = <0.0001 for both at all spatial scaling factor (SSF) values) and mean intensity following filtration for SSF 3-6 mm (p = 0.0002-0.0018). Abnormal expression of PSMA within the TZ is associated with altered texture on T2-weighted MR, providing validation of MRTA for the detection of TZ prostate cancer. (orig.)

  3. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bates, Anthony [Princess Alexandra Hospital, Brisbane (Australia); Miles, Kenneth [Princess Alexandra Hospital, Department of Diagnostic Radiology, Brisbane, QLD (Australia); University College London, Institute of Nuclear Medicine, London (United Kingdom)

    2017-12-15

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at <5%. Eighty-eight T2-weighted images in 18 patients demonstrated abnormal PSMA expression within the TZ on PET-MR. 123 images were PSMA negative. Based on the corrected p-value of 0.005, significant differences between PSMA positive and negative slices were found for 16 texture parameters: Standard deviation and mean of positive pixels for all spatial filters (p = <0.0001 for both at all spatial scaling factor (SSF) values) and mean intensity following filtration for SSF 3-6 mm (p = 0.0002-0.0018). Abnormal expression of PSMA within the TZ is associated with altered texture on T2-weighted MR, providing validation of MRTA for the detection of TZ prostate cancer. (orig.)

  4. Comparison between the 13C-urea breath test and stool antigen test for the diagnosis of childhood Helicobacter pylori infection

    International Nuclear Information System (INIS)

    Kato, Seiichi; Minoura, Takanori; Iinuma, Kazuie; Konno, Mutsuko; Tajiri, Hitoshi; Matsuhisa, Takeshi

    2004-01-01

    As noninvasive tests for Helicobacter pylori infection, the 13 C-urea breath test (UBT) and stool antigen test have been widely used. In children, however, there are few studies reporting which test shows superior performance. The purpose of this study was to compare the 13 C-UBT and stool antigen test for their accuracy in diagnosing. H. pylori infection in children. A total of 123 Japanese children, ages 2 to 17 years (mean, 12 years) who underwent gastric biopsies for H. pylori infection were studied. The diagnoses included gastritis (n=55), gastric ulcer (n=5), duodenal ulcer (n=20), iron-deficiency anemia (n=7), and other conditions (n=36). The cutoff value of the 13 C-UBT was defined to be 3.5 per mille. The stool antigen test was performed using the H. pylori stool antigen (HpSA) enzyme-linked immunosorbent assay (ELISA) (Premier Platinum HpSA). In 16 patients who received eradication therapy, the 13 C-UBT and HpSA were repeated 2 months after treatment. Based on biopsy tests, 60 children were infected with H. pylori and 63 children were not. For the 13 C-UBT, the sensitivity, specificity, and accuracy were 95.0% (95% confidence interval [CI], 86.1%-99.0%), 98.4% (95% CI, 91.5%-100%), and 96.4% (95% CI, 93.6%-99.9%), respectively. For the HpSA, the sensitivity, specificity, and accuracy were 983.% (95% CI, 90.8%-100%), 98.4% (95% CI, 91.2%-100%), and 98.3% (95% CI, 96.0%-100%), respectively. There were no significant differences between the performance of these two tests. In the assessment of H. pylori eradication, the results of 13 C-UBT and HpSA agreed with those of biopsy tests. The 13 C-UBT and the HpSA are equally accurate for the diagnosis of active H. pylori infection in Japanese children. (author)

  5. Improvements on an ELISA to detect trypanosomal antigens and its use as a monitoring tool in tsetse and trypanosomosis control programmes

    Energy Technology Data Exchange (ETDEWEB)

    Dwinger, R H; Rebeski, D; Winger, E [Joint FAO/IAEA Div. of Nuclear Techniques in Food and Agriculture, Vienna (Austria). Animal Production and Health Section

    1997-02-01

    Monoclonal antibodies directed at epitopes of Trypanosoma brucei, T. congolense and T. vivax have been used to capture and detect trypanosomal antigens in bovine blood samples using an enzyme-linked immunosorbent assay (ELISA) developed elsewhere. The test has been transformed in a ready-to-use kit format for distribution among a network of 15 African research institutes. The specificity of the test was assessed under experimental and field conditions and found to be 96% ({+-} 2%) for T. brucei, 99.5% ({+-}1%) for T. congolense and 99% ({+-}1%) for T. vivax. Following a validation period under field conditions, adjustments were made to the protocol to increase the sensitivity of the ELISA and to improve the suitability of the test for laboratory use under African conditions. Presently the ag-ELISA is being applied in conjunction with conventional parasitological techniques such as the buffy coat technique (BCT) to monitor progress in various tsetse and trypanosomosis control programmes and in a tsetse eradication effort on the island of Zanzibar. The two tests complement each other; the serological test tends to produce more false negatives during subacute infections, while the parasitological techniques tend to produce more false negatives during chronic infections. Since the sensitivity of the ELISA is not optimal, research efforts at the FAO/IAEA Agriculture and Biotechnology Laboratory will be focused on improving this aspect. However, these efforts are severely hampered by the lack of a diagnostic test that can be used as a ``gold standard``. The use of the polymerase chain reaction for verifying doubtful test results and as a possible candidate for a ``gold standard`` to diagnose trypanosomosis are discussed. Finally, future plans are outlined to initiate the use of geographical information systems to assess the impact of tsetse control and eradication programmes on land use and disease distribution. (author). 8 refs.

  6. Comparison of a Stool Antigen Detection Kit and PCR for Diagnosis of Entamoeba histolytica and Entamoeba dispar Infections in Asymptomatic Cyst Passers in Iran

    OpenAIRE

    Solaymani-Mohammadi, Shahram; Rezaian, Mostafa; Babaei, Zahra; Rajabpour, Azam; Meamar, Ahmad R.; Pourbabai, Ahmad A.; Petri, William A.

    2006-01-01

    The present study was conducted to compare stool antigen detection with PCR for the diagnosis of Entamoeba sp. infection in asymptomatic cyst passers from Iran. Entamoeba dispar and, in one case, E. moshkovskii were the Entamoeba spp. found in the amebic cyst passers. There was a 100% correlation between the results from the TechLab E. histolytica II stool antigen kit and those from nested PCR. We concluded that E. dispar is much more common in asymptomatic cyst passers in Iran and that antig...

  7. Detection of H5 Avian Influenza Viruses by Antigen-Capture Enzyme-Linked Immunosorbent Assay Using H5-Specific Monoclonal Antibody▿

    OpenAIRE

    He, Qigai; Velumani, Sumathy; Du, Qingyun; Lim, Chee Wee; Ng, Fook Kheong; Donis, Ruben; Kwang, Jimmy

    2007-01-01

    The unprecedented spread of highly pathogenic avian influenza virus subtype H5N1 in Asia and Europe is threatening animals and public health systems. Effective diagnosis and control management are needed to control the disease. To this end, we developed a panel of monoclonal antibodies (MAbs) against the H5N1 avian influenza virus (AIV) and implemented an antigen-capture enzyme-linked immunosorbent assay (AC-ELISA) to detect the H5 viral antigen. Mice immunized with denatured hemagglutinin (H...

  8. Spot test kit for explosives detection

    Science.gov (United States)

    Pagoria, Philip F; Whipple, Richard E; Nunes, Peter J; Eckels, Joel Del; Reynolds, John G; Miles, Robin R; Chiarappa-Zucca, Marina L

    2014-03-11

    An explosion tester system comprising a body, a lateral flow membrane swab unit adapted to be removeably connected to the body, a first explosives detecting reagent, a first reagent holder and dispenser operatively connected to the body, the first reagent holder and dispenser containing the first explosives detecting reagent and positioned to deliver the first explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body, a second explosives detecting reagent, and a second reagent holder and dispenser operatively connected to the body, the second reagent holder and dispenser containing the second explosives detecting reagent and positioned to deliver the second explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body.

  9. Comparison of nasopharyngeal aspirate and nasal swab specimens for detection of respiratory syncytial virus in different settings in a developing country

    DEFF Research Database (Denmark)

    Stensballe, L G; Trautner, S; Kofoed, P-E

    2002-01-01

    detection was defined as any test being positive. RESULTS: RSV antigen was detected in 84 (13%) children, the prevalence being 19% (41/219) among infants aged 230) in older children. Sensitivity of antigen detection was higher in NPA (92...

  10. Paraneoplastic antigen Ma2 autoantibodies as specific blood biomarkers for detection of early recurrence of small intestine neuroendocrine tumors.

    Science.gov (United States)

    Cui, Tao; Hurtig, Monica; Elgue, Graciela; Li, Su-Chen; Veronesi, Giulia; Essaghir, Ahmed; Demoulin, Jean-Baptiste; Pelosi, Giuseppe; Alimohammadi, Mohammad; Öberg, Kjell; Giandomenico, Valeria

    2010-12-30

    Small intestine neuroendocrine tumors (SI-NETs) belong to a rare group of cancers. Most patients have developed metastatic disease at the time of diagnosis, for which there is currently no cure. The delay in diagnosis is a major issue in the clinical management of the patients and new markers are urgently needed. We have previously identified paraneoplastic antigen Ma2 (PNMA2) as a novel SI-NET tissue biomarker. Therefore, we evaluated whether Ma2 autoantibodies detection in the blood stream is useful for the clinical diagnosis and recurrence of SI-NETs. A novel indirect ELISA was set up to detect Ma2 autoantibodies in blood samples of patients with SI-NET at different stages of disease. The analysis was extended to include typical and atypical lung carcinoids (TLC and ALC), to evaluate whether Ma2 autoantibodies in the blood stream become a general biomarker for NETs. In total, 124 blood samples of SI-NET patients at different stages of disease were included in the study. The novel Ma2 autoantibody ELISA showed high sensitivity, specificity and accuracy with ROC curve analysis underlying an area between 0.734 and 0.816. Ma2 autoantibodies in the blood from SI-NET patients were verified by western blot and sequential immunoprecipitation. Serum antibodies of patients stain Ma2 in the tumor tissue and neurons. We observed that SI-NET patients expressing Ma2 autoantibody levels below the cutoff had a longer progression and recurrence-free survival compared to those with higher titer. We also detected higher levels of Ma2 autoantibodies in blood samples from TLC and ALC patients than from healthy controls, as previously shown in small cell lung carcinoma samples. Here we show that high Ma2 autoantibody titer in the blood of SI-NET patients is a sensitive and specific biomarker, superior to chromogranin A (CgA) for the risk of recurrence after radical operation of these tumors.

  11. Tests to Detect Colorectal Cancer and Polyps

    Science.gov (United States)

    ... follow-up care needed after the test The convenience of the test The cost of the test ... by digital rectal examination: A comparison with recommended sampling practice. Annals of Internal Medicine 2005; 142(2): ...

  12. Detection of excretory Entamoeba histolytica DNA in the urine, and detection of E. histolytica DNA and lectin antigen in the liver abscess pus for the diagnosis of amoebic liver abscess

    Directory of Open Access Journals (Sweden)

    Khairnar Krishna

    2007-05-01

    Full Text Available Abstract Background Amoebic liver abscess (ALA and pyogenic liver abscesses (PLA appear identical by ultrasound and other imaging techniques. Collection of blood or liver abscess pus for diagnosis of liver abscesses is an invasive procedure, and the procedure requires technical expertise and disposable syringes. Collection of urine is a noninvasive procedure. Therefore, there has been much interest shown towards the use of urine as an alternative clinical specimen for the diagnosis of some parasitic infections. Here, we report for the first time the detection of E. histolytica DNA excreted in the urine for diagnosis of the cases of ALA. Results E. histolytica DNA was detected in liver abscess pus specimen of 80.4% of ALA patients by a nested multiplex polymerase chain reaction (PCR targeting 16S-like r RNA gene. The nested PCR detected E. histolytica DNA in all 37 (100% liver abscess pus specimens collected prior to metronidazole treatment, but were detected in only 53 of 75 (70.6% pus specimens collected after therapy with metronidazole. Similarly, the PCR detected E. histolytica DNA in 21 of 53 (39.6% urine specimens of ALA patients. The test detected E. histolytica DNA in only 4 of 23 (17.4% urine specimens collected prior to metronidazole treatment, but were detected in 17 of 30 (56.7% urine specimens collected after treatment with metronidazole. The enzyme-linked immunosorbent assay (ELISA for the detection of lectin E. histolytica antigen in the liver abscess pus showed a sensitivity of 50% and the indirect haemagglutination (IHA test for detection of amoebic antibodies in the serum showed a sensitivity of 76.8% for the diagnosis of the ALA. Conclusion The present study for the first time shows that the kidney barrier in ALA patients is permeable to E. histolytica DNA molecule resulting in excretion of E. histolytica DNA in urine which can be detected by PCR. The study also shows that the PCR for detection of E. histolytica DNA in urine of

  13. I-125 input into antibodies molecules specific to australian antigen

    International Nuclear Information System (INIS)

    Abdukayumov, A. M.; Chistyakov, P.G.; Garajshina, G. R.

    1999-01-01

    There are experimental data on I-125 input into antibodies molecules specific to superficial antigen of hepatitis B virus (australian antigen). Three ways of input are submitted: with the help of T chloramine usage, Bolton-Hunter Reagent and with the help of iodogen. There are also comparative characteristics of iodized products obtained: molar radioactivity, radiochemical frequency, immuno - reactivity. The report also discusses advantages and disadvantages of the used methods for inputting I-125 into antibodies to australian antigen in order to study the possibility of creating radio immunological test system for detecting superficial antigen of B hepatitis

  14. Sequential Analysis: Hypothesis Testing and Changepoint Detection

    Science.gov (United States)

    2014-07-11

    maintains the flexibility of deciding sooner than the fixed sample size procedure at the price of some lower power [13, 514]. The sequential probability... markets , detection of signals with unknown arrival time in seismology, navigation, radar and sonar signal processing, speech segmentation, and the... skimming cruise missile can yield a significant increase in the probability of raid annihilation. Furthermore, usually detection systems are

  15. Assessment of the repeatability and border-plate effects of the B158/B60 enzyme-linked-immunosorbent assay for the detection of circulating antigens (Ag-ELISA) of Taenia saginata.

    Science.gov (United States)

    Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah

    2016-08-30

    The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Validation of pre-coated ELISA tests to detect antibodies against T. congolense and T. vivax

    International Nuclear Information System (INIS)

    Shumba, W.

    2000-01-01

    The anti-trypanosomal antibody detecting enzyme linked immunosorbent assay (ELISA) was first described in 1977 and was further developed for use in large scale surveys in Zimbabwe. More recently, the IAEA initiated a programme to improve the robustness and standardisation of the assay. The IAEA supplied plates pre-coated with either a crude T. congolense or T. vivax antigen and the reagents necessary for analysing samples. Parasitologically positive and negative sera were used to validate and determine the cut-off values of the two tests. The samples were tested and results analysed using a variety of cut-off values. The tests provided similar information although the T. congolense pre-coated plates gave significantly higher optical density values than the plates coated with T. vivax. Sensitivity and specificity values were calculated using the different cut-off points. Results indicate that the test using T. congolense antigen had the highest specificity and sensitivity for a given cut-off value. Although the test could distinguish positive from negative sera, it was quite difficult to provide a suitable cut-off value, but the value should be dictated by the use of the test. (author)

  17. Grafting of a peptide probe for Prostate-Specific Antigen detection using diazonium electroreduction and click chemistry.

    Science.gov (United States)

    Strzemińska, I; Sainte Rose Fanchine, S; Anquetin, G; Reisberg, S; Noël, V; Pham, M C; Piro, B

    2016-07-15

    The main objective of this work was to validate a label-free electrochemical method of protein detection using peptides as capture probes. As a proof-of-concept, we used a 7 amino acids sequence (HSSKLQL) specific for Prostate Specific Antigen. We investigated various electrografting conditions of two anilines (2-[(4-aminophenyl)sulfanyl]-8-hydroxy-1,4-naphthoquinone and 4-azidoaniline) further converted in situ into their corresponding diazonium salts on glassy carbon electrodes. It was demonstrated that the best method to obtain a mixed layer is the simultaneous electroreduction of the two diazonium salts. 4-azidoaniline was used to covalently immobilize the ethynyl-functionalized peptide probe by click coupling, and the hydroxynaphthoquinone derivative plays the role of electrochemical transducer of the peptide-protein recognition. The proteolytic activity of PSA towards a small peptide substrate carrying streptavidin at its distal end was also investigated to design an original sensing architecture leading to a reagentless, label free, and "signal-on" PSA sensor. Without optimization, the limit of quantification can be estimated in the nM to pM range. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Impacto do uso da prova rápida para estreptococo beta-hemolítico do grupo A no diagnóstico e tratamento da faringotonsilite aguda em pronto-socorro de Pediatria Impacto del uso de la prueba rápida para estreptococos beta-hemolíticos del grupo A en el diagnóstico y tratamiento de la faringotonsilitis en emergencia de Pediatría Impact of the rapid antigen detection test in diagnosis and treatment of acute pharyngotonsillitis in a Pediatric emergency room

    Directory of Open Access Journals (Sweden)

    Débora Morais Cardoso

    2013-03-01

    estudiados, antimicrobianos serían prescritos a 389 individuos (59,8% y, con el uso de la investigación de estreptococos del grupo A se los prescribieron a 286 pacientes (44,0%. De los 261 niños que no recibirían antibióticos por el cuadro clínico, 111 (42,5% tuvieron investigación de estreptococos del grupo A positiva. El diagnóstico basado en el cuadro clínico presentó sensibilidad del 61,1%, especificidad del 47,7%, valor predictivo positivo del 44,9% y valor predictivo negativo del 57,5%, CONCLUSIONES: En este estudio, el diagnóstico clínico de la faringotonsilitis estreptocócica mostró baja sensibilidad y especificidad. El uso de rutina de la prueba rápida para investigación de estreptococos permitió la reducción del uso de antibióticos y la identificación de un grupo de riesgo para las complicaciones de la infección estreptocócica, pues el 42,5% de los pacientes con prueba rápida positiva no recibirían antibióticos si se llevara en consideración solamente el diagnóstico clínico.OBJECTIVE: To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. METHODS: This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. RESULTS: 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%; using the rapid antigen detection test, they were prescribed for 286 patients (44.0%. Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5% had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. CONCLUSIONS: The clinical

  19. Detection of polyomavirus simian virus 40 tumor antigen DNA in AIDS-related systemic non-Hodgkin lymphoma

    Science.gov (United States)

    Vilchez, Regis A.; Lednicky, John A.; Halvorson, Steven J.; White, Zoe S.; Kozinetz, Claudia A.; Butel, Janet S.

    2002-01-01

    Systemic non-Hodgkin lymphoma (S-NHL) is a common malignancy during HIV infection, and it is hypothesized that infectious agents may be involved in the etiology. Epstein-Barr virus DNA is found in <40% of patients with AIDS-related S-NHL, suggesting that other oncogenic viruses, such as polyomaviruses, may play a role in pathogenesis. We analyzed AIDS-related S-NHL samples, NHL samples from HIV-negative patients, peripheral blood leukocytes from HIV-infected and -uninfected patients without NHL, and lymph nodes without tumors from HIV-infected patients. Specimens were examined by polymerase chain reaction analysis with use of primers specific for an N-terminal region of the oncoprotein large tumor antigen ( T-ag ) gene conserved among all three polyomaviruses (simian virus 40 [SV40], JC virus, and BK virus). Polyomavirus T-ag DNA sequences, proven to be SV40-specific, were detected more frequently in AIDS-related S-NHL samples (6 of 26) than in peripheral blood leukocytes from HIV-infected patients (6 of 26 vs. 0 of 69; p =.0001), NHL samples from HIV-negative patients (6 of 26 vs. 0 of 10; p =.09), or lymph nodes (6 of 26 vs. 0 of 7; p =.16). Sequences of C-terminal T-ag DNA from SV40 were amplified from two AIDS-related S-NHL samples. Epstein-Barr virus DNA sequences were detected in 38% (10 of 26) AIDS-related S-NHL samples, 50% (5 of 10) HIV-negative S-NHL samples, and 57% (4 of 7) lymph nodes. None of the S-NHL samples were positive for both Epstein-Barr virus DNA and SV40 DNA. Further studies of the possible role of SV40 in the pathogenesis of S-NHL are warranted.

  20. Water Pollution Detection Based on Hypothesis Testing in Sensor Networks

    Directory of Open Access Journals (Sweden)

    Xu Luo

    2017-01-01

    Full Text Available Water pollution detection is of great importance in water conservation. In this paper, the water pollution detection problems of the network and of the node in sensor networks are discussed. The detection problems in both cases of the distribution of the monitoring noise being normal and nonnormal are considered. The pollution detection problems are analyzed based on hypothesis testing theory firstly; then, the specific detection algorithms are given. Finally, two implementation examples are given to illustrate how the proposed detection methods are used in the water pollution detection in sensor networks and prove the effectiveness of the proposed detection methods.

  1. Extent and effects of recurrent shortages of purified-protein derivative tuberculin skin test antigen solutions - United States, 2013.

    Science.gov (United States)

    2013-12-13

    Two purified-protein derivative (PPD) tuberculin skin test (TST) antigen solutions are approved by the U.S. Food and Drug Administration (FDA): Tubersol (Sanofi Pasteur Limited) and Aplisol (JHP Pharmaceuticals, LLC). Tubersol was out of production in late 2012 through April 2013. Shortages of Aplisol have resulted from increased demand as practitioners have sought a substitute for Tubersol. Tubersol production resumed in May 2013, and supplies had been nearly restored by early June. However, in mid-July, state tuberculosis (TB) control officials notified CDC of difficulty obtaining Tubersol and Aplisol. Sanofi Pasteur notified FDA of a temporary delay in the availability of tuberculin in the 10-dose and 50-dose presentations. In mid-October, the 10-dose presentation was being returned to market, on allocation, which means that historical purchasing practices determine the amount that customers are allotted. In late October, the 50-dose presentation was being returned to market, also on allocation, one vial per historical customer per month. Supplies are forecast to approach normal during January 2014, after distributors have restored their supply chains. A compensatory surge in testing after deferment of testing during the periods of shortage might cause further temporary instability of supplies. In mid-August 2013, officials in 29 of 52 U.S. jurisdictions noted a shortage of at least one PPD TST antigen solution in health departments to the extent that it interrupted activities. This report includes a summary of the extent and effects of the shortages and a reiteration of advice on how to adapt to them.

  2. Comparison of commercial diagnostic tests for identification of serogroup antigens of Neisseria meningitidis

    NARCIS (Netherlands)

    van der Ende, A.; Schuurman, I. G.; Hopman, C. T.; Fijen, C. A.; Dankert, J.

    1995-01-01

    In the study that is described the sensitivities and specificities of three commercial tests and the standard Reference Laboratory test, used since 1961, to identify Neisseria meningitidis serogroups were compared. The tests marketed by Difco, Murex/Wellcome, and Sanofi/Pasteur showed overall

  3. System tuning and measurement error detection testing

    International Nuclear Information System (INIS)

    Krejci, Petr; Machek, Jindrich

    2008-09-01

    The project includes the use of the PEANO (Process Evaluation and Analysis by Neural Operators) system to verify the monitoring of the status of dependent measurements with a view to early measurement fault detection and estimation of selected signal levels. At the present stage, the system's capabilities of detecting measurement errors was assessed and the quality of the estimates was evaluated for various system configurations and the formation of empiric models, and rules were sought for system training at chosen process data recording parameters and operating modes. The aim was to find a suitable system configuration and to document the quality of the tuned system on artificial failures

  4. Evaluation of antigen detection and polymerase chain reaction for diagnosis of amoebic liver abscess in patients on anti-amoebic treatment

    Directory of Open Access Journals (Sweden)

    Jaiswal Virendra

    2012-08-01

    Full Text Available Abstract Background Diagnosis of amoebic liver abscess (ALA in patients on anti-amoebic drugs is difficult. There is scanty data on this issue using Entamoeba histolytica (E. histolytica lectin antigen and polymerase chain reaction (PCR. We studied utility of lectin antigen, PCR, and IgG antibody in diagnosis of liver abscess in patients on anti-amoebic treatment. Liver aspirate of 200 patients, of which 170 had anti-amoebic drug prior to drainage, was tested for E. histolytica lectin antigen by (ELISA, PCR, bacterial culture, and serum IgG antibody by (ELISA. Classification of abscesses was based on result of anti-amoebic IgG antibody and bacterial culture, E. histolytica PCR and bacterial culture, and E. histolytica lectin antigen and bacterial culture. Findings Using anti-amoebic IgG antibody and bacterial culture, 136/200 (68.0% were classified as ALA, 12/200 (6.0% as pyogenic liver abscess (PLA, 29/200 (14.5% as mixed infection, and 23/200 (11.5% remained unclassified. Using amoebic PCR and bacterial culture 151/200 (75.5% were classified as ALA, 25/200 (12.5% as PLA, 16/200 (8.0% as mixed infection, and 8/200 (4.0% remained unclassified. With E. histolytica lectin antigen and bacterial culture, 22/200 (11.0% patients were classified as ALA, 39/200 (19.5% as PLA, 2/200 (1.0% as mixed infection, and 137/200 (68.5% remained unclassified. Conclusions E. histolytica lectin antigen was not suitable for classification of ALA patients who had prior anti-amoebic treatment. However, PCR may be used as alternative test to anti-amoebic antibody in diagnosis of ALA.

  5. Paraneoplastic antigen Ma2 autoantibodies as specific blood biomarkers for detection of early recurrence of small intestine neuroendocrine tumors.

    Directory of Open Access Journals (Sweden)

    Tao Cui

    Full Text Available BACKGROUND: Small intestine neuroendocrine tumors (SI-NETs belong to a rare group of cancers. Most patients have developed metastatic disease at the time of diagnosis, for which there is currently no cure. The delay in diagnosis is a major issue in the clinical management of the patients and new markers are urgently needed. We have previously identified paraneoplastic antigen Ma2 (PNMA2 as a novel SI-NET tissue biomarker. Therefore, we evaluated whether Ma2 autoantibodies detection in the blood stream is useful for the clinical diagnosis and recurrence of SI-NETs. METHODOLOGY/PRINCIPAL FINDINGS: A novel indirect ELISA was set up to detect Ma2 autoantibodies in blood samples of patients with SI-NET at different stages of disease. The analysis was extended to include typical and atypical lung carcinoids (TLC and ALC, to evaluate whether Ma2 autoantibodies in the blood stream become a general biomarker for NETs. In total, 124 blood samples of SI-NET patients at different stages of disease were included in the study. The novel Ma2 autoantibody ELISA showed high sensitivity, specificity and accuracy with ROC curve analysis underlying an area between 0.734 and 0.816. Ma2 autoantibodies in the blood from SI-NET patients were verified by western blot and sequential immunoprecipitation. Serum antibodies of patients stain Ma2 in the tumor tissue and neurons. We observed that SI-NET patients expressing Ma2 autoantibody levels below the cutoff had a longer progression and recurrence-free survival compared to those with higher titer. We also detected higher levels of Ma2 autoantibodies in blood samples from TLC and ALC patients than from healthy controls, as previously shown in small cell lung carcinoma samples. CONCLUSION: Here we show that high Ma2 autoantibody titer in the blood of SI-NET patients is a sensitive and specific biomarker, superior to chromogranin A (CgA for the risk of recurrence after radical operation of these tumors.

  6. Usefulness of Toxoplasma gondii recombinant antigens (GRA1, GRA7 and SAG1) in an immunoglobulin G avidity test for the serodiagnosis of toxoplasmosis

    DEFF Research Database (Denmark)

    Pietkiewicz, H; Hiszczyńska-Sawicka, E; Kur, J

    2007-01-01

    The precise diagnosis of an acute and recent Toxoplasma infection in pregnant women and the newborn child is important before treatment. This study describes a new Toxoplasma gondii IgG avidity test based on a combination of recombinant GRA1, GRA7 and SAG1 antigens and shows that this test is use...

  7. Adult T-cell leukemia-associated antigen (ATLA): detection of a glycoprotein in cell- and virus-free supernatant.

    Science.gov (United States)

    Yamamoto, N; Schneider, J; Hinuma, Y; Hunsmann, G

    1982-01-01

    A glycoprotein of an apparent molecular mass of 46,000, gp 46, was enriched by affinity chromatography from the virus- and cell-free culture medium of adult T-cell leukemia virus (ATLV) infected cells. gp 46 was specifically precipitated with sera from patients with adult T-cell leukemia associated antigen (ATLA). Thus, gp 46 is a novel component of the ATLA antigen complex.

  8. Laser Spot Center Detection and Comparison Test

    Science.gov (United States)

    Zhu, Jun; Xu, Zhengjie; Fu, Deli; Hu, Cong

    2018-04-01

    High efficiency and precision of the pot center detection are the foundations of avionics instrument navigation and optics measurement basis for many applications. It has noticeable impact on overall system performance. Among them, laser spot detection is very important in the optical measurement technology. In order to improve the low accuracy of the spot center position, the algorithm is improved on the basis of the circle fitting. The pretreatment is used by circle fitting, and the improved adaptive denoising filter for TV repair technology can effectively improves the accuracy of the spot center position. At the same time, the pretreatment and de-noising can effectively reduce the influence of Gaussian white noise, which enhances the anti-jamming capability.

  9. Efficiency of Direct Microscopy of Stool Samples Using an Antigen-Specific Adhesin Test for Entamoeba Histolytica

    Directory of Open Access Journals (Sweden)

    Arzu İrvem

    2016-10-01

    Full Text Available Background: E. histolytica is among the common causes of acute gastroenteritis. The pathogenic species E. histolytica and the nonpathogenic species E. dispar cannot be morphologically differentiated, although correct identification of these protozoans is important for treatment and public health. In many laboratories, the screening of leukocytes, erythrocytes, amoebic cysts, trophozoites and parasite eggs is performed using Native-Lugol’s iodine for pre-diagnosis. Aims: In this study, we aimed to investigate the frequency of E. histolytica in stool samples collected from 788 patients residing in the Anatolian region of İstanbul who presented with gastrointestinal complaints. We used the information obtained to evaluate the effectiveness of microscopic examinations when used in combination with the E. histolytica adhesin antigen test. Study Design: Retrospective cross-sectional study Methods: Preparations of stool samples stained with Native-Lugol’s iodine were evaluated using the E. histolytica adhesin test and examined using standard light microscopy at ×40 magnification. Pearson’s Chi-square and Fisher’s exact tests were used for statistical analysis. Logistic regression analysis was used for multivariate analysis. Results: Of 788 samples, 38 (4.8% were positive for E. histolytica adhesin antigens. When evaluated together with the presences of erythrocytes, leukocytes, cysts, and trophozoites, respectively, using logistic regression analysis, leukocyte positivity was significantly higher. The odds ratio of leukocyte positivity increased adhesin test-positivity by 2,530-fold (95% CI=1.01–6.330. Adhesin test-positivity was significant (p=0.047. Conclusion: In line with these findings, the consistency between the presence of cysts and erythrocytes and adhesin test-positivity was found to be highly significant, but that of higher levels of leukocytes was found to be discordant. It was concluded that leukocytes and trophozoites were

  10. DIAGNOSTIC ROLE OF FLUORINE-18 (18F) FLUORODEOXYGLUCOSE POSITRON EMISSION TOMOGRAPHY COMPUTED TOMOGRAPHY IN DETECTING RECURRENT DISEASE IN PATIENTS WITH COLORECTAL CANCER AND ELEVATED CARCINOEMBRYONIC ANTIGEN.

    Science.gov (United States)

    Matovina, Emil; Mihailović, Jasna; Nikoletić, Katarina; Srbovan, Dolores

    2015-01-01

    Early detection of recurrence is an important factor for long term survival of patients with colorectal cancer. Measurement of serum levels of carcinoembryonic antigen has been commonly used in the postoperative surveillance of colorectal cancer. The purpose of this study was to evaluate the ability of positron emission tomography-computed tomography to detect pathological substrate of elevated serum carcinoembryonic antigen in patients with colorectal cancer. The patients with colorectal cancer who underwent curative surgical resection and/ or chemotherapy, who were found in our database, were analyzed retrospectively. Forty-eight 18F-fluorodeoxyglucose positron emission tomography-computed tomography studies including 45 patients (14 women, 31 men; mean age: 62.93 years) with elevated serum, carcinoembryonic antigen levels, which had been performed between January 2011 and January 2014, were evaluated. Serum levels of carcinoembryonic antigen were measured within 3 months after positron emission tomography-computed tomography examination. Final diagnosis of recurrence was made by histopathological findings, radiology studies or clinical follow-up. Recurrences were diagnosed in 37 patients, the prevalence being 77.1%. Liver metastases were found in 18 patients, abdominal, pelvic and/or mediastinal lymph nodes were positive in 19 patients, 11 patients had loco regional recurrences and 4 patients had pulmonary metastasis, and bone metastases were found in one patient. One patient was diagnosed with metastasis in scar tissue. The overall sensitivity and specificity of positron emission tomography-computed tomography was 90.24% and 71.42%, respectively. The positive and negative predictive values were 94.87% and 55.56%, respectively. 18F-fluorodeoxyglucose positron emission tomography-computed tomography is a powerful tool that could be used in determining colorectal cancer recurrence in patients with elevated carcinoembryonic antigen levels and could have an

  11. Impact of the Legionella urinary antigen test on epidemiological trends in community outbreaks of legionellosis in Catalonia, Spain, 1990-2004.

    Science.gov (United States)

    Alvarez, Josep; Domínguez, Angela; Sabrià, Miquel; Ruiz, Laura; Torner, Nuria; Cayla, Joan; Barrabeig, Irene; Sala, M Rosa; Godoy, Pere; Camps, Neus; Minguell, Sofia

    2009-11-01

    To describe the characteristics of community outbreaks of legionellosis in Catalonia, Spain from 1990 to 2004, to compare two time periods (1990-1996 and 1997-2004), and to assess the influence of outbreak characteristics on the case fatality rate (CFR). This is a descriptive analysis of the outbreaks detected by epidemiological surveillance units in Catalonia. Variables potentially related to the CFR were analyzed by logistic regression. Of the 118 outbreaks involving 690 patients (overall CFR 4.5%), the urinary antigen test (UAT) was used for first case diagnosis in 80.5%. The origin of the outbreak was identified as a cooling tower in 35.6%, as a water distribution system in a public building in 14.4%, and a water distribution system at other sites in 7.6%. Statistically significant differences were found in the CFR (12.2% vs. 3.9%; p=0.018) and detection of the first case by UAT (0.0% vs. 87.2%; pcases involved in outbreaks of legionellosis.

  12. Prostate specific antigen testing policy worldwide varies greatly and seems not to be in accordance with guidelines: a systematic review

    Directory of Open Access Journals (Sweden)

    Van der Meer Saskia

    2012-10-01

    Full Text Available Abstract Background Prostate specific antigen (PSA testing is widely used, but guidelines on follow-up are unclear. Methods We performed a systematic review of the literature to determine follow-up policy after PSA testing by general practitioners (GPs and non-urologic hospitalists, the use of a cut-off value for this policy, the reasons for repeating a PSA test after an initial normal result, the existence of a general cut-off value below which a PSA result is considered normal, and the time frame for repeating a test. Data sources. MEDLINE, Embase, PsychInfo and the Cochrane library from January 1950 until May 2011. Study eligibility criteria. Studies describing follow-up policy by GPs or non-urologic hospitalists after a primary PSA test, excluding urologists and patients with prostate cancer. Studies written in Dutch, English, French, German, Italian or Spanish were included. Excluded were studies describing follow-up policy by urologists and follow-up of patients with prostate cancer. The quality of each study was structurally assessed. Results Fifteen articles met the inclusion criteria. Three studies were of high quality. Follow-up differed greatly both after a normal and an abnormal PSA test result. Only one study described the reasons for not performing follow-up after an abnormal PSA result. Conclusions Based on the available literature, we cannot adequately assess physicians’ follow-up policy after a primary PSA test. Follow-up after a normal or raised PSA test by GPs and non-urologic hospitalists seems to a large extent not in accordance with the guidelines.

  13. First systematic experience of preimplantation genetic diagnosis for single-gene disorders, and/or preimplantation human leukocyte antigen typing, combined with 24-chromosome aneuploidy testing.

    Science.gov (United States)

    Rechitsky, Svetlana; Pakhalchuk, Tatiana; San Ramos, Geraldine; Goodman, Adam; Zlatopolsky, Zev; Kuliev, Anver

    2015-02-01

    To study the feasibility, accuracy, and reproductive outcome of 24-chromosome aneuploidy testing (24-AT), combined with preimplantation genetic diagnosis (PGD) for single-gene disorders (SGDs) or human leukocyte antigen (HLA) typing in the same biopsy sample. Retrospective study. Preimplantation genetic diagnosis center. A total of 238 PGD patients, average age 36.8 years, for whom 317 combined PGD cycles were performed, involving 105 different conditions, with or without HLA typing. Whole-genome amplification product, obtained in 24-AT, was used for PGD and/or HLA typing in the same blastomere or blastocyst biopsy samples. Proportion of the embryos suitable for transfer detected in these blastomere or blastocyst samples, and the resulting pregnancy and spontaneous abortion rates. Embryos suitable for transfer were detected in 42% blastocyst and 25.1% blastomere samples, with a total of 280 unaffected, HLA-matched euploid embryos detected for transfer in 212 cycles (1.3 embryos per transfer), resulting in 145 (68.4%) unaffected pregnancies and birth of 149 healthy, HLA-matched children. This outcome is significantly different from that of our 2,064 PGD cycle series without concomitant 24-AT, including improved pregnancy (68.4% vs. 45.4%) and 3-fold spontaneous abortion reduction (5.5% vs. 15%) rates. The introduced combined approach is a potential universal PGD test, which in addition to achieving extremely high diagnostic accuracy, significantly improves reproductive outcomes of PGD for SGDs and HLA typing in patients of advanced reproductive age. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  14. Evaluation of the antibody-detection ELISA using plates precoated with denatured T. congolense and T. vivax antigens for monitoring tsetse and trypanosomosis control in Zambia

    International Nuclear Information System (INIS)

    Machila, N.; Sinyangwe, L.; Eisler, M.C.

    2000-01-01

    An evaluation of the indirect enzyme-linked immunosorbent assay (ELISA) for the detection of anti-trypanosomal antibodies in bovine serum was conducted using ELISA plates pre-coated with denatured T. congolense and T. vivax antigen. The study was conducted on 280 samples from a parasitologically positive cattle population and 200 samples from a negative cattle population. The overwhelming majority of trypanosome infections in the parasitologically positive cattle were T. congolense. The Ab-ELISA was able to discriminate between the negative and positive cattle populations, at an optimum cut-off point of 40% positivity (T. congolense antigen), with 89% sensitivity and 86% specificity; and for the T. vivax antigen, the optimum cut-off point was at 30%, with 81% sensitivity and 70% specificity. However, the optical densities (OD) and percentage positivity (PP) values for sera from both the reference positive and negative cattle populations were unacceptably high particularly in the ELISA using T. congolense antigen. Furthermore the quality control sera used in the assay appear to have inappropriately low OD and PP values by comparison to typical sera from the reference positive and negative cattle populations. It is suggested that these ELISA's be re-titrated using more appropriate quality assurance sera. This should result in OD and PP values for sera from the reference populations failing within acceptable ranges. (author)

  15. Prostate-specific antigen (PSA) testing of men in UK general practice: a 10-year longitudinal cohort study.

    Science.gov (United States)

    Young, Grace J; Harrison, Sean; Turner, Emma L; Walsh, Eleanor I; Oliver, Steven E; Ben-Shlomo, Yoav; Evans, Simon; Lane, J Athene; Neal, David E; Hamdy, Freddie C; Donovan, Jenny L; Martin, Richard M; Metcalfe, Chris

    2017-10-30

    Cross-sectional studies suggest that around 6% of men undergo prostate-specific antigen (PSA) testing each year in UK general practice (GP). This longitudinal study aims to determine the cumulative testing pattern of men over a 10-year period and whether this testing can be considered equivalent to screening for prostate cancer (PCa). Patient-level data on PSA tests, biopsies and PCa diagnoses were obtained from the UK Clinical Practice Research Datalink (CPRD) for the years 2002 to 2011. The cumulative risks of PSA testing and of being diagnosed with PCa were estimated for the 10-year study period. Associations of a man's age, region and index of multiple deprivation with the cumulative risk of PSA testing and PCa diagnosis were investigated. Rates of biopsy and diagnosis, following a high test result, were compared with those from the programme of PSA testing in the Prostate Testing for Cancer and Treatment (ProtecT) study. The 10-year risk of exposure to at least one PSA test in men aged 45 to 69 years in UK GP was 39.2% (95% CI 39.0 to 39.4%). The age-specific risks ranged from 25.2% for men aged 45-49 years to 53.0% for men aged 65-69 years (p for trend PSA level ≥3, a test in UK GP was less likely to result in a biopsy (6%) and/or diagnosis of PCa (15%) compared with ProtecT study participants (85% and 34%, respectively). A high proportion of men aged 45-69 years undergo PSA tests in UK GP: 39% over a 10-year period. A high proportion of these tests appear to be for the investigation of lower urinary tract symptoms and not screening for PCa. ISRCTN20141297,NCT02044172. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Antigen persistence of rapid diagnostic tests in pregnant women in Nanoro, Burkina Faso, and the implications for the diagnosis of malaria in pregnancy.

    Science.gov (United States)

    Kattenberg, Johanna H; Tahita, Christian M; Versteeg, Inge A J; Tinto, Halidou; Traoré-Coulibaly, Maminata; Schallig, Henk D F H; Mens, Petra F

    2012-05-01

    To evaluate persistence of several Plasmodium antigens in pregnant women after treatment and compare diagnostics during treatment follow-up. Thirty-two pregnant women (N = 32) with confirmed malaria infection by a histidine-rich protein 2 (HRP2)-based rapid diagnostic test (RDT) and microscopy were followed for 28 days after artemisinin-based combination therapy (ACT). A Plasmodium lactate dehydrogenase (pLDH)-based RDT and two ELISAs based on the detection of dihydrofolate reductase-thymidylate synthase (DHFR-TS) and haeme detoxification protein (HDP) were compared with each other and to RT-PCR at each visit. The mean visit number (95% confidence interval) on which the HRP2-based RDT was still positive after treatment was 3.4 (2.7-4.1) visits with some patients still positive at day 28. This is significantly later than the pLDH-based RDT [0.84 (0.55-1.1)], microscopy (median 1, range 1-3), DHFR-TS-ELISA [1.7 (1.1-2.3)] and RT-PCR (median 2, range 1-5) (P pregnant women and can generate problems when using this test during intermittent preventive treatment (IPTp). DHFR-TS is less persistent than HRP2, making it a potentially interesting target for diagnosis. © 2012 Blackwell Publishing Ltd.

  17. Immunohistochemical detection and correlation between MHC antigen and cell-mediated immune system in recurrent glioma by APAAP method.

    Science.gov (United States)

    Miyagi, K; Ingram, M; Techy, G B; Jacques, D B; Freshwater, D B; Sheldon, H

    1990-09-01

    As part of an on-going clinical trial of immunotherapy for recurrent malignant gliomas, using alkaline phosphatase-anti-alkaline phosphatase method with monoclonal antibodies, we investigated the correlation between expression of the major histocompatibility complex (MHC) and the subpopulation of tumor-infiltrating lymphocytes (TILs) in 38 glioma specimens (20 grade IV, 11 grade III, and 7 grade II) from 33 patients. Thirty specimens (78.9%) were positive to class I MHC antigen and 20 (52.6%) were positive to class II MHC antigen. The correlations between class I MHC antigen expression and the number of infiltrating T8 (p less than 0.01), and also between class II MHC antigen expression and the number of infiltrating T4 (p less than 0.05) were significant. We conclude that TILs are the result of immunoreaction (host-defense mechanism). 31.6% of specimens had perivascular infiltration of T cells. The main infiltrating lymphocyte subset in moderate to marked perivascular cuffing was T4. Our results may indicate that lack of MHC antigen on the glioma cell surface has a share in the poor immunogenicity in glioma-bearing patients. In addition, considering the effector/target ratio, the number of infiltrating lymphocytes against glioma cells was too small, so the immunological intervention seems to be essential in glioma therapy. Previous radiation therapy and chemotherapy, including steroid therapy, did not influence lymphocyte and macrophage infiltration.

  18. The Utility of the helicobacter pylori stool antigen test in managing ...

    African Journals Online (AJOL)

    Conclusion and recommendations: The HPSAT may be used in the test and treat strategy for young patients with dyspep- sia without alarm signs and symptoms in low resource settings. However, because of its low validity in predicting H.pylori associated disease, it is important to follow up patients so that if symptoms ...

  19. Imperfection detection probability at ultrasonic testing of reactor vessels

    International Nuclear Information System (INIS)

    Kazinczy, F. de; Koernvik, L.Aa.

    1980-02-01

    The report is a lecture given at a symposium organized by the Swedish nuclear power inspectorate on February 1980. Equipments, calibration and testing procedures are reported. The estimation of defect detection probability for ultrasonic tests and the reliability of literature data are discussed. Practical testing of reactor vessels and welded joints are described. Swedish test procedures are compared with other countries. Series of test data for welded joints of the OKG-2 reactor are presented. Future recommendations for testing procedures are made. (GBn)

  20. Detection of rabies antigen in the saliva and brains of apparently healthy dogs slaughtered for human consumption and its public health implications in abia state, Nigeria.

    Science.gov (United States)

    Mshelbwala, P P; Ogunkoya, A B; Maikai, B V

    2013-01-01

    The study was carried out in eight dogs slaughtering outlets within four Local Government Areas of the State for the determination of rabies antigen in the saliva and brain of apparently healthy dogs slaughtered for human consumption. A total of one hundred (100) samples each of saliva and brain were collected before and after slaughter, respectively, between April to June, 2013, in the selected areas. The saliva was subjected to rapid immune-chromatographic test (RICT) while direct fluorescent antibody test (DFAT) was carried out on the brain samples. Structured questionnaire was administered to nineteen (19) dog meat processors comprising 18 males and 1 female in the selected areas. Sixty four percent of the samples tested were from female dogs while 36% were from males, 5% tested positive for rabies antigen with the use of both tests; there was no statistical association between sex and rabies status of the dogs sampled (P > 0.05). Butchers bitten during the course of slaughtering were 94.7% out of which 72.8% utilized traditional method of treatment and only 27.8% reported to the hospital for proper medical attention. This study has established the presence of rabies antigen in apparently healthy dogs in the study area.

  1. Aspergillus Polymerase Chain Reaction: Systematic Review of Evidence for Clinical Use in Comparison With Antigen Testing

    Science.gov (United States)

    White, P. Lewis; Wingard, John R.; Bretagne, Stéphane; Löffler, Jürgen; Patterson, Thomas F.; Slavin, Monica A.; Barnes, Rosemary A.; Pappas, Peter G.; Donnelly, J. Peter

    2015-01-01

    Background. Aspergillus polymerase chain reaction (PCR) was excluded from the European Organisation for the Research and Treatment of Cancer/Mycoses Study Group (EORTC/MSG) definitions of invasive fungal disease because of limited standardization and validation. The definitions are being revised. Methods. A systematic literature review was performed to identify analytical and clinical information available on inclusion of galactomannan enzyme immunoassay (GM-EIA) (2002) and β-d-glucan (2008), providing a minimal threshold when considering PCR. Categorical parameters and statistical performance were compared. Results. When incorporated, GM-EIA and β-d-glucan sensitivities and specificities for diagnosing invasive aspergillosis were 81.6% and 91.6%, and 76.9% and 89.4%, respectively. Aspergillus PCR has similar sensitivity and specificity (76.8%–88.0% and 75.0%–94.5%, respectively) and comparable utility. Methodological recommendations and commercial PCR assays assist standardization. Although all tests have limitations, currently, PCR is the only test with independent quality control. Conclusions. We propose that there is sufficient evidence that is at least equivalent to that used to include GM-EIA and β-d-glucan testing, and that PCR is now mature enough for inclusion in the EORTC/MSG definitions. PMID:26113653

  2. Central nervous system blastomycosis diagnosed using the MVista® Blastomyces quantitative antigen enzyme immunoassay test on cerebrospinal fluid: A case report and review of the literature.

    Science.gov (United States)

    Walkty, Andrew; Keynan, Yoav; Karlowsky, James; Dhaliwal, Perry; Embil, John

    2018-02-01

    Blastomyces dermatitidis is a thermally dimorphic fungus that is capable of causing pulmonary and extra-pulmonary disease, including infections of the central nervous system (CNS). Diagnosis of CNS blastomycosis with non-invasive testing can be difficult, and a surgical biopsy may ultimately be required for microbiological and/or histopathological confirmation. A case of B. dermatitidis meningitis is presented where the diagnosis was made by testing cerebrospinal fluid (CSF) using the MVista® Blastomyces Quantitative Antigen Enzyme Immunoassay test. The utility of performing this test on CSF for diagnosis of CNS mass lesions/abscesses caused by B. dermatitidis in the absence of associated meningitis remains unclear. Cross reaction of the Blastomyces antigen test with other dimorphic fungi is a concern, necessitating that positive test results are interpreted in the context of the patient's exposure and travel history. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Evaluation of envelope glycoprotein E(rns) of an atypical bovine pestivirus as antigen in a microsphere immunoassay for the detection of antibodies against bovine viral diarrhea virus 1 and atypical bovine pestivirus.

    Science.gov (United States)

    Vijayaraghavan, Balaje; Xia, Hongyan; Harimoorthy, Rajiv; Liu, Lihong; Belák, Sándor

    2012-11-01

    Atypical bovine pestiviruses are related antigenically and phylogenetically to bovine viral diarrhea viruses (BVDV-1 and BVDV-2), and may cause the same clinical manifestations in animals. Glycoprotein E(rns) of an atypical bovine pestivirus Th/04_KhonKaen was produced in a baculovirus expression system and was purified by affinity chromatography. The recombinant E(rns) protein was used as an antigen in a microsphere immunoassay for the detection of antibodies against BVDV-1 and atypical bovine pestivirus. The diagnostic performance of the new method was evaluated by testing a total of 596 serum samples, and the assay was compared with enzyme-linked immunosorbent assay (ELISA). Based on the negative/positive cut-off median fluorescence intensity (MFI) value of 2800, the microsphere immunoassay had a sensitivity of 100% and specificity of 100% compared to ELISA. The immunoassay was able to detect antibodies against both BVDV-1 and the atypical pestivirus. This novel microsphere immunoassay has the potential to be multiplexed for simultaneous detection of antibodies against different bovine pathogens in a high-throughput and economical way. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Kepler Planet Detection Metrics: Statistical Bootstrap Test

    Science.gov (United States)

    Jenkins, Jon M.; Burke, Christopher J.

    2016-01-01

    This document describes the data produced by the Statistical Bootstrap Test over the final three Threshold Crossing Event (TCE) deliveries to NExScI: SOC 9.1 (Q1Q16)1 (Tenenbaum et al. 2014), SOC 9.2 (Q1Q17) aka DR242 (Seader et al. 2015), and SOC 9.3 (Q1Q17) aka DR253 (Twicken et al. 2016). The last few years have seen significant improvements in the SOC science data processing pipeline, leading to higher quality light curves and more sensitive transit searches. The statistical bootstrap analysis results presented here and the numerical results archived at NASAs Exoplanet Science Institute (NExScI) bear witness to these software improvements. This document attempts to introduce and describe the main features and differences between these three data sets as a consequence of the software changes.

  5. Multianalyte Tests for the Early Detection of Cancer: Speedbumps and Barriers

    Directory of Open Access Journals (Sweden)

    Michael A. Tainsky

    2007-01-01

    Full Text Available It has become very clear that a single molecular event is inadequate to accurately predict the biology (or pathophysiology of cancer. Furthermore, using any single molecular event as a biomarker for the early detection of malignancy may not comprehensively identify the majority of individuals with that disease. Therefore, the fact that technologies have arisen that can simultaneously detect several, possibly hundreds, of biomarkers has propelled the field towards the development of multianalyte-based in vitro diagnostic early detection tests for cancer using body fl uids such as serum, plasma, sputum, saliva, or urine. These multianalyte tests may be based on the detection of serum autoantibodies to tumor antigens, the presence of cancer-related proteins in serum, or the presence of tumor-specific genomic changes that appear in plasma as free DNA. The implementation of non-invasive diagnostic approaches to detect early stage cancer may provide the physician with evidence of cancer, but the question arises as to how the information will affect the pathway of clinical intervention. The confirmation of a positive result from an in vitro diagnostic cancer test may involve relatively invasive procedures to establish a true cancer diagnosis. If in vitro diagnostic tests are proven to be both specific, i.e. rarely produce false positive results due to unrelated conditions, and sufficiently sensitive, i.e. rarely produce false negative results, then such screening tests offer the potential for early detection and personalized therapeutics using multiple disease-related targets with convenient and non-invasive means. Here we discuss the technical and regulatory barriers inherent in development of clinical multianalyte biomarker assays.

  6. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  7. Antigen-specific secretion of IFNγ and CXCL10 in whole blood assay detects Mycobacterium leprae infection but does not discriminate asymptomatic infection from symptomatic leprosy.

    Science.gov (United States)

    Hungria, Emerith Mayra; Freitas, Aline Araújo; Pontes, Maria Araci Andrade; Gonçalves, Heitor Sá; Sousa, Ana Lúcia Osório Maroccolo; Costa, Maurício Barcelos; Castilho, Mirian Lane Oliveira Rodrigues; Duthie, Malcolm S; Stefani, Mariane Martins Araújo

    2017-04-01

    To advance toward a whole blood assay (WBA)-based test capable of facilitating the diagnosis of paucibacillary (PB) leprosy, we evaluated a prototype in-tube WBA using combinations of Mycobacterium leprae antigens. Blood was collected from newly diagnosed untreated PB (n=38), multibacillary (MB) (n=30), healthy household contacts (HHC) of MB (n=27), and endemic controls (n=61) residing in Goiânia and Fortaleza, Brazil. Blood was incubated with M. leprae cell sonicate, recombinant proteins (46f+LID-1; ML0276+LID-1), or controls (phosphate-buffered saline, phytohemagglutinin, M. tuberculosis purified protein derivative). Antigen-specific IFNγ production was observed in 71-84% and 55% of PB and HHC, respectively. Antigen-specific CXCL10 levels were similarly assessed to determine if, unlike IFNγ, CXCL10 could differentiate PB from HHC with repeated exposure/asymptomatic M. leprae infection. The CXCL10 levels induced in response to M. leprae antigens could not, however, differentiate PB from HHC. Despite these limitations, the WBAs reported here still represent important tools for assessing M. leprae infection rates and evaluating the impact of control measures. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Impact of the European Randomized Study of Screening for Prostate Cancer (ERSPC) on prostate-specific antigen (PSA) testing by Dutch general practitioners

    NARCIS (Netherlands)

    Van der Meer, Saskia; Kollen, Boudewijn J.; Hirdes, Willem H.; Steffens, Martijn G.; Hoekstra-Weebers, Josette E. H. M.; Nijman, Rien M.; Blanker, Marco H.

    Objective To determine the impact of the European Randomized Study of Screening for Prostate Cancer (ERSPC) publication in 2009 on prostate-specific antigen (PSA) level testing by Dutch general practitioners (GPs) in men aged 40 years. Materials and Methods Retrospective study with a Dutch insurance

  9. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  10. The Use of Fluoroproline in MUC1 Antigen Enables Efficient Detection of Antibodies in Patients with Prostate Cancer

    NARCIS (Netherlands)

    Somovilla, Víctor J; Bermejo, Iris A.; Albuquerque, Inês S; Martínez-Sáez, Nuria; Castro-López, Jorge; García-Martín, Fayna; Compañón, Ismael; Hinou, Hiroshi; Nishimura, Shin-Ichiro; Jiménez-Barbero, Jesús; Asensio, Juan L.; Avenoza, Alberto; Busto, Jesús H.; Hurtado-Guerrero, Ramón; Peregrina, Jesús M.; Bernardes, Gonçalo J L; Corzana, Francisco

    2017-01-01

    A structure-based design of a new generation of tumor-associated glycopeptides with improved affinity against two anti-MUC1 antibodies is described. These unique antigens feature a fluorinated proline residue, such as a (4S)-4-fluoro-l-proline or 4,4-difluoro-l-proline, at the most immunogenic

  11. Detection of Immune-Complex Dissociated Nonstructural-1 (NS-1) Antigen in Patients with Acute Dengue Virus Infections

    NARCIS (Netherlands)

    P. Koraka (Penelope); C.P. Burghoorn-Maas; A. Falconar; T.E. Setiati (Tatty); K. Djamiatun; J. Groen (Jan); A.D.M.E. Osterhaus (Albert)

    2003-01-01

    textabstractAccurate and timely diagnosis of dengue virus (DEN) infections is essential for the differential diagnosis of patients with febrile illness and hemorrhagic fever. In the present study, the diagnostic value of a newly developed immune-complex dissociated nonstructural-1 (NS-1) antigen dot

  12. KAtex antigen-detection test as a diagnostic tool for latent visceral ...

    African Journals Online (AJOL)

    SERVER

    2008-04-03

    Apr 3, 2008 ... mostly fertile with some covered by forest. The climate of the mountainous areas includes a snowy winter, a rainy spring and a mild summer. The temperatures vary considerably from season to season as well as from place to place with a minimum of - 20ºC and a maximum over 35ºC in some localities.

  13. Application of Bayesian Methods for Detecting Fraudulent Behavior on Tests

    Science.gov (United States)

    Sinharay, Sandip

    2018-01-01

    Producers and consumers of test scores are increasingly concerned about fraudulent behavior before and during the test. There exist several statistical or psychometric methods for detecting fraudulent behavior on tests. This paper provides a review of the Bayesian approaches among them. Four hitherto-unpublished real data examples are provided to…

  14. Clinical outcomes of prostate cancer patients in Yokosuka City, Japan: A comparative study between cases detected by prostate-specific antigen-based screening in Yokosuka and those detected by other means.

    Science.gov (United States)

    Sakai, Naoki; Taguri, Masataka; Kobayashi, Kazuki; Noguchi, Sumio; Ikeda, Shigeru; Koh, Hideshige; Satomi, Yoshiaki; Furuhata, Akihiko

    2015-08-01

    To investigate whether prostate-specific antigen-based screening reduced the prostate cancer mortality rate in Yokosuka, Japan. We carried out a cohort study, in which we compared clinical outcomes between patients detected by prostate-specific antigen-based screening (S group n = 524) versus those detected by other means (NS group n = 1044). Clinical and pathological factors were evaluated using Cox regression analyses and the Kaplan-Meier method. A total of 1.5% (8/524) of patients in the S group and 6.7% (70/1044) of those in the NS group died from prostate cancer during follow up. A total of 8.0% (42/524) of patients in the S group and 11.4% (119/1044) in the NS group died from other causes. The 10-year cancer specific survival rates of the S and NS groups were 97% and 86%, respectively (P prostate-specific antigen 100 ng/mL or more was significantly lower in the S group than the NS group: 7.8% and 23.0%, respectively (P specific survival (hazard ratio 4.808, 95% confidence interval 1.044-22.14, P = 0.044). Prostate-specific antigen-based population screening in Yokosuka City might help to reduce the prostate cancer mortality rate. © 2015 The Japanese Urological Association.

  15. Detection of prostate specific antigen (PSA) in human saliva using an ultra-sensitive nanocomposite of graphene nanoplatelets with diblock-co-polymers and Au electrodes.

    Science.gov (United States)

    Khan, M S; Dighe, K; Wang, Z; Srivastava, I; Daza, E; Schwartz-Dual, A S; Ghannam, J; Misra, S K; Pan, D

    2018-02-26

    Prostate-specific antigen (PSA) is a commonly used biomarker for the detection of prostate cancer (PCa) and there are numerous data available for its invasive detection in the serum and whole blood. In this work, an electrochemical sensing method was devised to detect traces of PSA in human saliva using a hybrid nanocomposite of graphene nanoplatelets with diblock co-polymers and Au electrodes (GRP-PS 67 -b-PAA 27 -Au). The pure graphitic composition on filter paper provides significantly high electrical and thermal conductivity while PS 67 -b-PAA 27 makes an amphiphilic bridge between GRP units. The sensor utilizes the binding of an anti-PSA antibody with an antigen-PSA to act as a resistor in a circuit providing an impedance change that in turn allows for the detection and quantification of PSA in saliva samples. A miniaturized electrical impedance analyzer was interfaced with a sensor chip and the data were recorded in real-time using a Bluetooth-enabled module. This fully integrated and optimized sensing device exhibited a wide PSA range of detection from 0.1 pg mL -1 to 100 ng mL -1 (R 2 = 0.963) with a lower limit of detection of 40 fg mL -1 . The performance of the biosensor chip was validated with an enzyme-linked immunosorbent assay technique with a regression coefficient as high as 0.940. The advantages of the newly developed saliva-PSA electrical biosensor over previously reported serum-PSA electrochemical biosensors include a faster response time (3-5 min) to achieve a stable electrical signal for PSA detection, high selectivity, improved sensitivity, no additional requirement of a redox electrolyte for electron exchange and excellent shelf life. The presented sensor is aimed for clinical commercialization to detect PSA in human saliva.

  16. HIV resistance testing and detected drug resistance in Europe

    DEFF Research Database (Denmark)

    Schultze, Anna; Phillips, Andrew N; Paredes, Roger

    2015-01-01

    to Southern Europe. CONCLUSIONS: Despite a concurrent decline in virological failure and testing, drug resistance was commonly detected. This suggests a selective approach to resistance testing. The regional differences identified indicate that policy aiming to minimize the emergence of resistance......OBJECTIVES: To describe regional differences and trends in resistance testing among individuals experiencing virological failure and the prevalence of detected resistance among those individuals who had a genotypic resistance test done following virological failure. DESIGN: Multinational cohort...... study. METHODS: Individuals in EuroSIDA with virological failure (>1 RNA measurement >500 on ART after >6 months on ART) after 1997 were included. Adjusted odds ratios (aORs) for resistance testing following virological failure and aORs for the detection of resistance among those who had a test were...

  17. Long-Term Effects of Antibodies Against Human Leukocyte Antigens Detected by Flow Cytometry in the First Year After Renal Transplantation

    Directory of Open Access Journals (Sweden)

    Tülay Kılıçaslan Ayna

    2013-03-01

    Full Text Available Objective: In this study, we aimed to investigate the incidence, dynamics and profiles of human leukocyte antigen (HLA-directed antibodies developed after transplantation and their impact on graft rejection and outcome in kidney recipients. Study Design: Prospective follow-up study. Material and Methods: A total of 56 kidney recipients were monitored at 1st, 6th and 12th months for the development of anti-HLA antibodies using bead based flow-cytometry assays (Flow PRA tests. Results: In 21 (37.5% patients, panel reactive antibodies (PRA was positive after transplantation, however, in 35 (62.5% patients PRA was found negative. Twelve (57.1% patients with post-transplantation HLA-reactive antibodies [PRA (+] and 8 (22.9% patients with no detectable alloantibodies [PRA (-] were developed allograft rejection (p=0.010. In the PRA positive patient group the rates of early period infection and delayed graft function (DGF were higher than the PRA negative patient group. Serum creatinine levels of PRA positive group at 6. and 12. months after transplantation were significantly higher than the PRA negative group (p=0.015 and p=0.048, respectively. The rejection rates of patients who had class I and II HLA antibodies were significantly higher than the patients who had either class I or II HLA antibodies (p=0.011. Acute rejection rates were significantly higher in patients who had class I and II HLA antibodies at the first month (p=0.007. Conclusion: Higher occurrence of rejection episodes in PRA positive group may show the importance of anti-HLA antibody monitoring using Flow-PRA after renal transplantation as a prognostic marker in terms of graft survival.

  18. A new trivalent SnSAG surface antigen chimera for efficient detection of antibodies against Sarcocystis neurona and diagnosis of equine protozoal myeloencephalitis.

    Science.gov (United States)

    Yeargan, Michelle; de Assis Rocha, Izabela; Morrow, Jennifer; Graves, Amy; Reed, Stephen M; Howe, Daniel K

    2015-05-01

    Enzyme-linked immunosorbent assays (ELISAs) based on the SnSAG surface antigens of Sarcocystis neurona provide reliable detection of infection by the parasite. Moreover, accurate serodiagnosis of equine protozoal myeloencephalitis (EPM) is achieved with the SnSAG ELISAs by measuring antibodies in serum and cerebrospinal fluid (CSF) to reveal active infection in the central nervous system. Two independent ELISAs based on recombinant (r)SnSAG2 or a chimeric fusion of SnSAG3 and SnSAG4 (rSnSAG4/3) are currently used together for EPM serodiagnosis to overcome varied antibody responses in different horses. To achieve reliable antibody detection with a single ELISA instead of 2 separate ELISAs, rSnSAG2 was fused with rSnSAG4/3 into a single trivalent protein, designated rSnSAG2/4/3. Paired serum and CSF from 163 horses were tested with all 3 ELISAs. When the consensus antibody titers obtained with the rSnSAG2 and rSnSAG4/3 ELISAs were compared to the single SAG2/4/3 ELISA titers, Spearman rank correlation coefficients of ρ = 0.74 and ρ = 0.90 were obtained for serum and CSF, respectively, indicating strong agreement between the tests. When the rSnSAG2 and rSnSAG4/3 consensus serum-to-CSF titer ratio was compared to the rSnSAG2/4/3 serum-to-CSF titer ratio, the Spearman correlation coefficient was ρ = 0.87, again signifying strong agreement. Importantly, comparing the diagnostic interpretation of the serum-to-CSF titer ratios yielded a Cohen kappa value of 0.77. These findings suggest that the single ELISA based on the trivalent rSnSAG2/4/3 will provide serologic and diagnostic results that are highly comparable to the consensus of the 2 independent ELISAs based on rSnSAG2 and rSnSAG4/3. © 2015 The Author(s).

  19. Comparison of a Clinical Prediction Rule and a LAM Antigen-Detection Assay for the Rapid Diagnosis of TBM in a High HIV Prevalence Setting

    Science.gov (United States)

    Patel, Vinod B.; Singh, Ravesh; Connolly, Cathy; Kasprowicz, Victoria; Zumla, Allimudin; Ndungu, Thumbi; Dheda, Keertan

    2010-01-01

    Background/Objective The diagnosis of tuberculous meningitis (TBM) in resource poor TB endemic environments is challenging. The accuracy of current tools for the rapid diagnosis of TBM is suboptimal. We sought to develop a clinical-prediction rule for the diagnosis of TBM in a high HIV prevalence setting, and to compare performance outcomes to conventional diagnostic modalities and a novel lipoarabinomannan (LAM) antigen detection test (Clearview-TB®) using cerebrospinal fluid (CSF). Methods Patients with suspected TBM were classified as definite-TBM (CSF culture or PCR positive), probable-TBM and non-TBM. Results Of the 150 patients, 84% were HIV-infected (median [IQR] CD4 count = 132 [54; 241] cells/µl). There were 39, 55 and 54 patients in the definite, probable and non-TBM groups, respectively. The LAM sensitivity and specificity (95%CI) was 31% (17;48) and 94% (85;99), respectively (cut-point ≥0.18). By contrast, smear-microscopy was 100% specific but detected none of the definite-TBM cases. LAM positivity was associated with HIV co-infection and low CD4 T cell count (CD4200 cells/µl; p = 0.03). The sensitivity and specificity in those with a CD4<100 cells/µl was 50% (27;73) and 95% (74;99), respectively. A clinical-prediction rule ≥6 derived from multivariate analysis had a sensitivity and specificity (95%CI) of 47% (31;64) and 98% (90;100), respectively. When LAM was combined with the clinical-prediction-rule, the sensitivity increased significantly (p<0.001) to 63% (47;68) and specificity remained high at 93% (82;98). Conclusions Despite its modest sensitivity the LAM ELISA is an accurate rapid rule-in test for TBM that has incremental value over smear-microscopy. The rule-in value of LAM can be further increased by combination with a clinical-prediction rule, thus enhancing the rapid diagnosis of TBM in HIV-infected persons with advanced immunosuppression. PMID:21203513

  20. Detection at a distance of atomic bomb tests

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, M E

    1954-01-01

    Nahmias describes the radioassay of air, rain, and snowfall as the basis for detecting atomic bomb tests. Tables and graphs give time vs. Ra equivalents, distance vs Roentgens/h of radiation, and distribution of radioelements which can be expected.

  1. Statistics of software vulnerability detection in certification testing

    Science.gov (United States)

    Barabanov, A. V.; Markov, A. S.; Tsirlov, V. L.

    2018-05-01

    The paper discusses practical aspects of introduction of the methods to detect software vulnerability in the day-to-day activities of the accredited testing laboratory. It presents the approval results of the vulnerability detection methods as part of the study of the open source software and the software that is a test object of the certification tests under information security requirements, including software for communication networks. Results of the study showing the allocation of identified vulnerabilities by types of attacks, country of origin, programming languages used in the development, methods for detecting vulnerability, etc. are given. The experience of foreign information security certification systems related to the detection of certified software vulnerabilities is analyzed. The main conclusion based on the study is the need to implement practices for developing secure software in the development life cycle processes. The conclusions and recommendations for the testing laboratories on the implementation of the vulnerability analysis methods are laid down.

  2. 68Ga-PSMA PET/CT in Patients with Rising Prostatic-Specific Antigen After Definitive Treatment of Prostate Cancer: Detection Efficacy and Diagnostic accuracy.

    Science.gov (United States)

    Hamed, Maged Abdel Galil; Basha, Mohammad Abd Alkhalik; Ahmed, Hussien; Obaya, Ahmed Ali; Afifi, Amira Hamed Mohamed; Abdelbary, Eman H

    2018-06-20

    68 Ga-prostate-specific membrane antigen-11 ( 68 Ga-PSMA-11) is a recently developed positron emission tomography (PET) tracer that can detect prostate cancer (PC) relapses and metastases with high contrast resolution. The aim of this study was to assess the detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT image in patients with rising prostatic-specific antigen (PSA) after treatment of PC. The present prospective study included 188 patients who exhibited rising of PSA level on a routine follow-up examination after definitive treatment of PC. All patients underwent a 68 Ga-PSMA PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value of the local recurrence and extraprostatic metastases. The detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT were established by histopathology and clinical and imaging follow-up as the reference standards. 68 Ga-PSMA PET/CT detected tumour relapse in 165 patients (35 patients had local recurrence, 106 patients had extraprostatic metastases, and 24 patients had combined lesions). The sensitivity, specificity, and accuracy values of 68 Ga-PSMA PET/CT examination in the detection of PC recurrence were 98.8%, 100%, and 98.8%, respectively. 68 Ga-PSMA PET/CT revealed an overall detection rate of 87.8% (165/188) in patients with rising PSA (median of 2.2 ng/mL, and range of 0.01-70 ng/mL). 68 Ga-PSMA PET/CT is a valuable tool for the detection of PC local recurrence or extraprostatic metastases following rising PSA levels after primary definitive therapy and should be incorporated during routine work-up. Copyright © 2018. Published by Elsevier Inc.

  3. Carcinoembryonic antigen (CEA)

    International Nuclear Information System (INIS)

    Ephraim, K.H.; Cox, P.H.; Hamer, C.J.A. v.d.; Berends, W.; Delhez, H.

    1977-01-01

    The carcinoembryonic antigen (CEA) is a complex of antigen determinants and also the carrier of these determinants. Chemically it is a glycoprotein. Its occurrence in blood serum or urine is correlated with malignant disease. Several radioimmunoassays (RIA) have been developed, one by Hoffmann-Laroche and one by the Rotterdam Radiotherapeutic Institute. Both methods and the Hoffmann assay kit are tested. Specifications are given for isolation of the antigen, preparation of the antiserum, and the execution of the RIA. Biochemical and clinical aspects are discussed

  4. IgG responses to Anopheles gambiae salivary antigen gSG6 detect variation in exposure to malaria vectors and disease risk

    DEFF Research Database (Denmark)

    Stone, Will; Bousema, Teun; Jones, Sophie

    2012-01-01

    as the basis of an immuno-assay determining exposure to Afrotropical malaria vectors. In the present study, IgG responses to gSG6 and 6 malaria antigens (CSP, AMA-1, MSP-1, MSP-3, GLURP R1, and GLURP R2) were compared to Anopheles exposure and malaria incidence in a cohort of children from Korogwe district...... with subsequent malaria incidence (test for trend p¿=¿0.004), comparable to malaria antigens MSP-1 and GLURP R2. Our results show that the gSG6 assay is sensitive to micro-epidemiological variations in exposure to Anopheles mosquitoes, and provides a correlate of malaria risk that is unrelated to immune...

  5. Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2015-01-01

    The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.

  6. Automation of the ELISpot assay for high-throughput detection of antigen-specific T-cell responses.

    Science.gov (United States)

    Almeida, Coral-Ann M; Roberts, Steven G; Laird, Rebecca; McKinnon, Elizabeth; Ahmed, Imran; Pfafferott, Katja; Turley, Joanne; Keane, Niamh M; Lucas, Andrew; Rushton, Ben; Chopra, Abha; Mallal, Simon; John, Mina

    2009-05-15

    The enzyme linked immunospot (ELISpot) assay is a fundamental tool in cellular immunology, providing both quantitative and qualitative information on cellular cytokine responses to defined antigens. It enables the comprehensive screening of patient derived peripheral blood mononuclear cells to reveal the antigenic restriction of T-cell responses and is an emerging technique in clinical laboratory investigation of certain infectious diseases. As with all cellular-based assays, the final results of the assay are dependent on a number of technical variables that may impact precision if not highly standardised between operators. When studies that are large scale or using multiple antigens are set up manually, these assays may be labour intensive, have many manual handling steps, are subject to data and sample integrity failure and may show large inter-operator variability. Here we describe the successful automated performance of the interferon (IFN)-gamma ELISpot assay from cell counting through to electronic capture of cytokine quantitation and present the results of a comparison between automated and manual performance of the ELISpot assay. The mean number of spot forming units enumerated by both methods for limiting dilutions of CMV, EBV and influenza (CEF)-derived peptides in six healthy individuals were highly correlated (r>0.83, pautomated system compared favourably with the manual ELISpot and further ensured electronic tracking, increased through-put and reduced turnaround time.

  7. Hepatitis C Core Antigen Testing for Diagnosis of Hepatitis C Virus Infection: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Freiman, J Morgan; Tran, Trang M; Schumacher, Samuel G; White, Laura F; Ongarello, Stefano; Cohn, Jennifer; Easterbrook, Philippa J; Linas, Benjamin P; Denkinger, Claudia M

    2016-09-06

    Diagnosis of chronic hepatitis C virus (HCV) infection requires both a positive HCV antibody screen and confirmatory nucleic acid testing (NAT). Testing for hepatitis C virus core antigen (HCVcAg) is a potential alternative to NAT. To evaluate the accuracy of diagnosis of active HCV infection among adults and children for 5 HCVcAg tests compared with NAT. EMBASE, PubMed, Web of Science, Scopus, and Cochrane Database of Systematic Reviews from 1990 through 31 March 2016. Case-control, cross-sectional, cohort, or randomized trials that compared any of 5 HCVcAg tests with an NAT reference standard. 2 independent reviewers extracted data and assessed quality using an adapted QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool. 44 studies evaluated 5 index tests. Studies for the Abbott ARCHITECT HCV Ag assay had the highest quality, whereas those for the Ortho HCV Ag enzyme-linked immunosorbent assay (ELISA) had the lowest quality. From bivariate analyses, the sensitivity and specificity of the assays were as follows: Abbott ARCHITECT, 93.4% (95% CI, 90.1% to 96.4%) and 98.8% (CI, 97.4% to 99.5%); Ortho ELISA, 93.2% (CI, 81.6% to 97.7%) and 99.2% (CI, 87.9% to 100%); and Hunan Jynda Bioengineering Group HCV Ag ELISA, 59.5% (CI, 46.0% to 71.7%) and 82.9% (CI, 58.6% to 94.3%). Insufficient data were available for a meta-analysis about the Fujirebio Lumipulse Ortho HCV Ag and Eiken Lumispot HCV Ag assays. In 3 quantitative studies using Abbott ARCHITECT, HCVcAg correlated closely with HCV RNA levels greater than 3000 IU/mL. Insufficient data were available on covariates, such as HIV or hepatitis B virus status, for subgroup analyses. Few studies reported genotypes of isolates, and data for genotypes 4, 5, and 6 were scant. Most studies were conducted in high-resource settings and reference laboratories. The HCVcAg assays with signal amplification have high sensitivity, high specificity, and good correlation with HCV RNA levels greater than 3000 IU/mL and

  8. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Hodge, Chris A.

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  9. Histocompatibility antigen test

    Science.gov (United States)

    ... Updated by: Frank A. Greco, MD, PhD, Director, Biophysical Laboratory, Edith Nourse Rogers Memorial Hospital, Bedford, MA. ... any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should ...

  10. Diagnostic validation of selected serological tests for detecting scrub typhus.

    Science.gov (United States)

    Koraluru, Munegowda; Bairy, Indira; Varma, Muralidhar; Vidyasagar, Sudha

    2015-07-01

    Clinical diagnosis of scrub typhus is often difficult because the symptoms are very similar to those of other febrile illness such as dengue, leptospirosis, malaria and other viral hemorrhagic fevers. Though better diagnostic tests are available for rickettsial diseases and scrub typhus elsewhere, the Weil-Felix test is still commonly used in India, mainly because microimmunofluorescence assays (M-IFA) were not available in India till recently and relevant staff had insufficient training. The present study was performed to investigate the performance of M-IFA, IgM ELISA, and Weil-Felix test on 546 non-repeated serum samples from subjects suspected of having scrub typhus. One hundred and forty-three of these 546 samples were positive by M-IFA; these cases were also confirmed clinically to have scrub typhus based on their dramatic responses to doxycycline therapy. IgM ELISA was positive in 122 of the 143 M-IFA positive cases and the Weil-Felix test in 96. Though the Weil-Felix test is a heterophile agglutination test, it was found in this study to have good specificity but far too little sensitivity to use as a routine diagnostic test. IgM ELISA can be a good substitute for M-IFA. Incorporation of multiple prototype antigens on M-IFA slides is likely one of the reasons for its superior performance. As newer and better diagnostic assays become available for scrub typhus diagnosis in developed countries, it will be imperative to also use such tests in other endemic countries to prevent over- or under-diagnosis of scrub typhus. © 2015 The Societies and Wiley Publishing Asia Pty Ltd.

  11. Commercial serological antibody detection tests for the diagnosis of pulmonary tuberculosis: a systematic review.

    Directory of Open Access Journals (Sweden)

    Karen R Steingart

    2007-06-01

    Full Text Available BACKGROUND: The global tuberculosis epidemic results in nearly 2 million deaths and 9 million new cases of the disease a year. The vast majority of tuberculosis patients live in developing countries, where the diagnosis of tuberculosis relies on the identification of acid-fast bacilli on unprocessed sputum smears using conventional light microscopy. Microscopy has high specificity in tuberculosis-endemic countries, but modest sensitivity which varies among laboratories (range 20% to 80%. Moreover, the sensitivity is poor for paucibacillary disease (e.g., pediatric and HIV-associated tuberculosis. Thus, the development of rapid and accurate new diagnostic tools is imperative. Immune-based tests are potentially suitable for use in low-income countries as some test formats can be performed at the point of care without laboratory equipment. Currently, dozens of distinct commercial antibody detection tests are sold in developing countries. The question is "do they work?" METHODS AND FINDINGS: We conducted a systematic review to assess the accuracy of commercial antibody detection tests for the diagnosis of pulmonary tuberculosis. Studies from all countries using culture and/or microscopy smear for confirmation of pulmonary tuberculosis were eligible. Studies with fewer than 50 participants (25 patients and 25 control participants were excluded. In a comprehensive search, we identified 68 studies. The results demonstrate that (1 overall, commercial tests vary widely in performance; (2 sensitivity is higher in smear-positive than smear-negative samples; (3 in studies of smear-positive patients, Anda-TB IgG by enzyme-linked immunosorbent assay shows limited sensitivity (range 63% to 85% and inconsistent specificity (range 73% to 100%; (4 specificity is higher in healthy volunteers than in patients in whom tuberculosis disease is initially suspected and subsequently ruled out; and (5 there are insufficient data to determine the accuracy of most

  12. Detection Test for Leakage of CO2 into Sodium Loop

    International Nuclear Information System (INIS)

    Park, Sun Hee; Wi, Myung-Hwan; Min, Jae Hong

    2015-01-01

    This report is about the facility for the detection test for leakage of CO 2 into sodium loop. The facility for the detection test for leakage of CO 2 into sodium loop was introduced. The test will be carried out. Our experimental results are going to be expected to be used for approach methods to detect CO 2 leaking into sodium in heat exchangers. A sodium-and-carbon dioxide (Na-CO 2 ) heat exchanger is one of the key components for the supercritical CO 2 Brayton cycle power conversion system of sodium-cooled fast reactors (SFRs). A printed circuit heat exchanger (PCHE) is considered for the Na-CO 2 heat exchanger, which is known to have potential for reducing the volume occupied by the exchangers compared to traditional shell-and-tube heat exchangers. Among various issues about the Na- CO 2 exchanger, detection of CO 2 leaking into sodium in the heat exchanger is most important thing for its safe operation. It is known that reaction products from sodium and CO 2 such as sodium carbonate (Na 2 CO 3 ) and amorphous carbon are hardly soluble in sodium, which cause plug sodium channels. Detection technique for Na 2 CO 3 in sodium loop has not been developed yet. Therefore, detection of CO 2 and CO from reaction of sodium and CO 2 are proper to detect CO 2 leakage into sodium loop

  13. Cascaded image analysis for dynamic crack detection in material testing

    Science.gov (United States)

    Hampel, U.; Maas, H.-G.

    Concrete probes in civil engineering material testing often show fissures or hairline-cracks. These cracks develop dynamically. Starting at a width of a few microns, they usually cannot be detected visually or in an image of a camera imaging the whole probe. Conventional image analysis techniques will detect fissures only if they show a width in the order of one pixel. To be able to detect and measure fissures with a width of a fraction of a pixel at an early stage of their development, a cascaded image analysis approach has been developed, implemented and tested. The basic idea of the approach is to detect discontinuities in dense surface deformation vector fields. These deformation vector fields between consecutive stereo image pairs, which are generated by cross correlation or least squares matching, show a precision in the order of 1/50 pixel. Hairline-cracks can be detected and measured by applying edge detection techniques such as a Sobel operator to the results of the image matching process. Cracks will show up as linear discontinuities in the deformation vector field and can be vectorized by edge chaining. In practical tests of the method, cracks with a width of 1/20 pixel could be detected, and their width could be determined at a precision of 1/50 pixel.

  14. Development of an indirect ELISA to detect Corynebacterium pseudotuberculosis specific antibodies in sheep employing T1 strain culture supernatant as antigen

    Directory of Open Access Journals (Sweden)

    Miriam F. Rebouças

    2013-11-01

    Full Text Available Corynebacterium pseudotuberculosis is the etiologic agent of caseous lymphadenitis (CLA, a chronic disease that affects goats and sheep, characterized by granuloma formation in subcutaneous and internal lymph nodes. CLA causes significant economic losses to commercial goat herds. In this study, we aimed to test secreted antigens secreted from T1 strain bacteria grown in brain heart infusion (BHI broth in an indirect ELISA system to determine the presence of specific immunoglobulins against C. pseudotuberculosis. We analyzed the BHI antigen electrophoretic profile and the recognition pattern by infected sheep sera samples. The ELISA results were compared with multiplex PCR assay and IFN-gamma production. The ELISA was able to discriminate between negative and positive animals, with a sensitivity of 89% and a specificity of 99%, using microbiological isolation as gold standard. When this assay was compared with multiplex PCR and specific IFN-gamma quantification, six discrepant results were found among thirty-two samples. We concluded that the ELISA using antigens secreted from C. pseudotuberculosis T1 strain growth in BHI broth culture can be used for the serodiagnosis of CLA in sheep.

  15. Cost-effectiveness of quantitative hepatitis B virus surface antigen testing in pregnancy in predicting vertical transmission risk.

    Science.gov (United States)

    Samadi Kochaksaraei, Golasa; Congly, Stephen E; Matwiy, Trudy; Castillo, Eliana; Martin, Steven R; Charlton, Carmen L; Coffin, Carla S

    2016-11-01

    Vertical transmission of hepatitis B virus (HBV) can occur despite immunoprophylaxis in mothers with high HBV DNA levels (>5-7 log 10 IU/ml). Quantitative hepatitis B surface antigen (qHBsAg) testing could be used as a surrogate marker to identify high viral load carriers, but there is limited data in pregnancy. We conducted a prospective observational study to determine the cost-effectiveness and utility of qHBsAg as a valid surrogate marker of HBV DNA. Pregnant patients with chronic hepatitis B were recruited from a tertiary referral centre. HBV DNA levels and qHBsAg were assessed in the second to third trimester. Statistical analysis was performed by Spearman's rank correlation and student's t-test. The cost-effectiveness of qHBsAg as compared to HBV DNA testing was calculated. Ninety nine women with 103 pregnancies, median age 32 years, 65% Asian, 23% African and 12% other [Hispanic, Caucasian] were enrolled. Overall, 23% (23/99) were HBV e Ag (HBeAg)-positive. A significant correlation between qHBsAg and HBV DNA levels was noted in HBeAg-positive patients (r = 0.79, P < 0.05) but not in HBeAg-negative patients (r = 0.17, P = 0.06). In receiver operating characteristic analysis, the optimal qHBsAg cut-off values for predicting maternal viraemia associated with immunoprophylaxis failure (i.e., HBV DNA ≥7 log 10 IU/ml) was 4.3 log 10 IU/ml (accuracy 98.7%, sensitivity 94.7%, specificity 94.4%) (95% CI, 97-100%, P < 0.05). Use of HBV DNA as compared to qHBsAg costs approximately $20 000 more per infection prevented. In resource poor regions, qHBsAg could be used as a more cost-effective marker for high maternal viraemia, and indicate when anti-HBV nucleos/tide analogue therapy should be used to prevent HBV immunoprophylaxis failure. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Carcinoembryonic Antigen Level in Liver Disease

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kyoo Ok; Kim, Ki Whang; Park, Chang Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1978-09-15

    Carcinoembryonic antigen was initially known as tumor specific antigen and had a potential diagnostic value in the detection of digestive tract malignancies. However, subsequent studies showed CEA and CEA-like antigen present in benign disease, particularly in liver. We had collected sera from 58 patients who had liver scan and later were diagnosed clinically and histologically as liver disease. We estimated CEA values and correlations were made with liver function tests in liver cirrhosis cases. The results: 1) The raised plasma carcinoembryonic antigen level were found in 13 (68.4%) of 19 patients cirrhosis, 5 (27.8%) of 18 patients in hepatoma, 5 (71%) of 7 patients in chronic active hepatitis, all 3 patients in liver abscesses, 2 (66.7%) of 3 patients in liver abscesses, 2 (66.7%) of 3 patients in obstructive biliary disease and none in each one patient of traumatic liver hematoma, subphrenic abscess and clonorchiasis. 2) There is no linear correlation between carcinoembryonic antigen level and liver function tests including serum bilirubin, alkaline phosphatase, SGOT and prothrombin time in liver patients.

  17. Carcinoembryonic Antigen Level in Liver Disease

    International Nuclear Information System (INIS)

    Choi, Kyoo Ok; Kim, Ki Whang; Park, Chang Yun

    1978-01-01

    Carcinoembryonic antigen was initially known as tumor specific antigen and had a potential diagnostic value in the detection of digestive tract malignancies. However, subsequent studies showed CEA and CEA-like antigen present in benign disease, particularly in liver. We had collected sera from 58 patients who had liver scan and later were diagnosed clinically and histologically as liver disease. We estimated CEA values and correlations were made with liver function tests in liver cirrhosis cases. The results: 1) The raised plasma carcinoembryonic antigen level were found in 13 (68.4%) of 19 patients cirrhosis, 5 (27.8%) of 18 patients in hepatoma, 5 (71%) of 7 patients in chronic active hepatitis, all 3 patients in liver abscesses, 2 (66.7%) of 3 patients in liver abscesses, 2 (66.7%) of 3 patients in obstructive biliary disease and none in each one patient of traumatic liver hematoma, subphrenic abscess and clonorchiasis. 2) There is no linear correlation between carcinoembryonic antigen level and liver function tests including serum bilirubin, alkaline phosphatase, SGOT and prothrombin time in liver patients.

  18. A Label-Free Microelectrode Array Based on One-Step Synthesis of Chitosan–Multi-Walled Carbon Nanotube–Thionine for Ultrasensitive Detection of Carcinoembryonic Antigen

    Directory of Open Access Journals (Sweden)

    Huiren Xu

    2016-07-01

    Full Text Available Carcinoembryonic antigen (CEA has been an extensively used tumor marker responsible for clinical early diagnosis of cervical carcinomas, and pancreatic, colorectal, gastric and lung cancer. Combined with micro-electro mechanical system (MEMS technology, it is important to develop a novel immune microelectrode array (MEA not only for rapid analysis of serum samples, but also for cell detection in vitro and in vivo. In this work, we depict a simple approach to modify chitosan–multi-walled carbon nanotubes–thionine (CS–MWCNTs–THI hybrid film through one-step electrochemical deposition and the CS-MWCNTs-THI hybrid films are successfully employed to immobilize anti-CEA for fabricating simple, label-free, and highly sensitive electro-chemical immune MEAs. The detection principle of immune MEA was based on the fact that the increasing formation of the antigen-antibody immunocomplex resulted in the decreased response currents and the relationship between the current reductions with the corresponding CEA concentrations was directly proportional. Experimental results indicated that the label-free MEA had good selectivity and the limit of detection for CEA is 0.5 pg/mL signal to noise ratio (SNR = 3. A linear calibration plot for the detection of CEA was obtained in a wide concentration range from 1 pg/mL to 100 ng/mL (r = 0.996. This novel MEA has potential applications for detecting CEA for the research on cancer cells and cancer tissue slices as well as for effective early diagnosis.

  19. High voltage-derived enhancement of electric conduction in nanogap devices for detection of prostate-specific antigen

    Science.gov (United States)

    Park, Hyung Ju; Chi, Young Shik; Choi, Insung S.; Yun, Wan Soo

    2010-07-01

    We report a simple method of enhancing electric conductance in nanogap devices without any additional treatments, such as silver-enhancing process. The low electric conductance after selective immobilization of biofunctionalized gold nanoparticles in the gap region was greatly enhanced by repeated I-V scans at relatively high voltage ranges of -5 to 5 V, which was attributed to the formation of a new conduction pathway across the gap. The higher conduction state of the nanogap device showed a very stable I-V curve, which was used as an excellent measure of the existence of prostate-specific antigen.

  20. Radioimmunoassays of hidden viral antigens

    International Nuclear Information System (INIS)

    Neurath, A.R.; Strick, N.; Baker, L.; Krugman, S.

    1982-01-01

    Antigens corresponding to infectious agents may be present in biological specimens only in a cryptic form bound to antibodies and, thus, may elude detection. We describe a solid-phase technique for separation of antigens from antibodies. Immune complexes are precipitated from serum by polyethylene glycol, dissociated with NaSCN, and adsorbed onto nitrocellulose or polystyrene supports. Antigens remain topographically separated from antibodies after removal of NaSCN and can be detected with radiolabeled antibodies. Genomes from viruses immobilized on nitrocellulose can be identified by nucleic acid hybridization. Nanogram quantities of sequestered hepatitis B surface and core antigens and picogram amounts of hepatitis B virus DNA were detected. Antibody-bound adenovirus, herpesvirus, and measles virus antigens were discerned by the procedure

  1. Surface antigens and potential virulence factors from parasites detected by comparative genomics of perfect amino acid repeats

    Directory of Open Access Journals (Sweden)

    Adler Joël

    2007-12-01

    Full Text Available Abstract Background Many parasitic organisms, eukaryotes as well as bacteria, possess surface antigens with amino acid repeats. Making up the interface between host and pathogen such repetitive proteins may be virulence factors involved in immune evasion or cytoadherence. They find immunological applications in serodiagnostics and vaccine development. Here we use proteins which contain perfect repeats as a basis for comparative genomics between parasitic and free-living organisms. Results We have developed Reptile http://reptile.unibe.ch, a program for proteome-wide probabilistic description of perfect repeats in proteins. Parasite proteomes exhibited a large variance regarding the proportion of repeat-containing proteins. Interestingly, there was a good correlation between the percentage of highly repetitive proteins and mean protein length in parasite proteomes, but not at all in the proteomes of free-living eukaryotes. Reptile combined with programs for the prediction of transmembrane domains and GPI-anchoring resulted in an effective tool for in silico identification of potential surface antigens and virulence factors from parasites. Conclusion Systemic surveys for perfect amino acid repeats allowed basic comparisons between free-living and parasitic organisms that were directly applicable to predict proteins of serological and parasitological importance. An on-line tool is available at http://genomics.unibe.ch/dora.

  2. Detection and confirmation of PPR virus antigen in sheep and goats by sandwich-ELISA and RT-PCR in Andhra Pradesh, India

    Directory of Open Access Journals (Sweden)

    G. Saritha

    2015-06-01

    Full Text Available Peste des petits ruminants (PPR is a highly contagious disease of domestic and wild small ruminants. Rapid and accurate laboratory assay are essential to enable the implementation of appropriate control strategies to restrict the spread of PPR. The present study was designed to detect the PPR virus (PPRV antigen (N-gene in nasal swabs and tissue samples. A total of 195 samples comprising of 138 nasal swabs from PPR suspected sheep (n=72 and goats (n=66, and 57 tissue samples comprising of lymph nodes from dead sheep (n=39 and goats (n=18 were collected from certain parts of Andhra Pradesh. The samples were subjected to sandwich-ELISA followed by RT-PCR for confirmatory diagnosis. In this study, PPRV could be detected in 27.53% (n=38/138 nasal swabs and 49.12% (n=28/57 tissue samples. Data showed that PPRV infection is widespread in the Andhra Pradesh, India.

  3. Limited Value of Assays Using Detection of Immunoglobulin G Antibodies to the Two Recombinant Dense Granule Antigens, GRA1 and GRA6 Nt of Toxoplasma gondii, for Distinguishing between Acute and Chronic Infections in Pregnant Women

    Science.gov (United States)

    Ferrandiz, Josette; Mercier, Corinne; Wallon, Martine; Picot, Stéphane; Cesbron-Delauw, Marie-France; Peyron, François

    2004-01-01

    An enzyme-linked immunosorbent assay (ELISA) using two recombinant antigens of Toxoplasma gondii (GRA1 and GRA6 Nt) was developed in order to differentiate between pregnant women with a serological profile of recently acquired infection and those with chronic infection. Both proteins were expressed in Escherichia coli as glutathione S-transferase fusion proteins. Thirty-two serum samples from subjects who presented seroconversion within 3 months before sampling (group 1; acute profile), 46 serum samples from women who had a positive serology at least 1 year before sampling (group 2; chronic profile), and 100 serum samples from pregnant women who were not infected by T. gondii (group 3) were examined for immunoglobulin G (IgG) reactivity. For both antigens, the specificity reached 98%. In both groups of infected patients, the overall sensitivity scored was 60% for GRA1 and 83% for GRA6 Nt. In group 1, 34% of sera reacted with GRA1 whereas 84% of sera reacted with GRA6 Nt; in group 2, however, sensitivities were 78.2 and 82.6%, respectively. Combination of the readings obtained with both antigens yielded a sensitivity of 91%. A serological follow-up of 10 women who seroconverted during pregnancy displayed three different serological patterns: (i) a GRA profile paralleling the IgG curve, as detected by the commercial kit, (ii) a GRA1 profile, or (iii) GRA1 and GRA6 Nt profiles remaining negative for at least 8 weeks after the reference test gave positive results. Taken together, these results suggest that neither GRA1 nor GRA6 Nt is sensitive enough to be used routinely to differentiate between acute and chronic toxoplasmic infections. PMID:15539499

  4. Detection of ductile crack initiation by acoustic emission testing

    International Nuclear Information System (INIS)

    Richter, H.; Boehmert, J.; Viehrig, H.W.

    1998-08-01

    A Charpy impact test equipment is described permitting simultaneous measurement of impact force, crack tip opening, acoustic emissions and magnetic emissions. The core of the equipment is an inverted pendulum ram impact testing machine and the tests have been performed with laterally notched, pre-fatigue ISO-V specimens made of steels of various strength and toughness properties. The tests are intended to ascertain whether the acoustic emission method is suitable for detecting steady crack initiation in highly ductile steels. (orig./CB) [de

  5. Patch test reactions to mite antigens: a GERDA multicentre study. Groupe d'Etudes et de Recherches en Dermato-Allergie.

    Science.gov (United States)

    Castelain, M; Birnbaum, J; Castelain, P Y; Ducombs, G; Grosshans, E; Jelen, G; Lacroix, M; Meynadier, J; Mougeolle, J M; Lachapelle, J M

    1993-11-01

    We performed patch tests with Dermatophagoides pteronyssinus (Dp) antigens from 2 different sources in 355 non-randomly selected patients with atopic dermatitis (AD) and 398 subjects of a control group. The study demonstrated that contact sensitization to mites occurred in an appreciable % of AD cases (20.8%), using commonly available assay products. The differences recorded between the 2 materials tested were related to the concentration of P1 antigen. Non-atopic patients rarely showed positive reactions to Dp (0.75%), when strict criteria for readings were applied and if 2 readings were performed. Patients with positive patch tests did not necessarily show positive immediate skin tests. It would be useful to carry out tests systematically in atopic patients, even if it is not yet known what modern treatment would be best for the patient. Laboratories still do not provide standardized house dust mite preparations--measuring and codifying their biological activity--for use in patch tests. It is to be hoped that the extension of this type of test will lead to the production of better test materials, in syringes with homogeneous dispersion and concentration.

  6. Extended flow cytometry characterization of normal bone marrow progenitor cells by simultaneous detection of aldehyde dehydrogenase and early hematopoietic antigens: implication for erythroid differentiation studies

    Directory of Open Access Journals (Sweden)

    Pascariello Caterina

    2008-05-01

    Full Text Available Abstract Background Aldehyde dehydrogenase (ALDH is a cytosolic enzyme highly expressed in hematopoietic precursors from cord blood and granulocyte-colony stimulating factor mobilized peripheral blood, as well as in bone marrow from patients with acute myeloblastic leukemia. As regards human normal bone marrow, detailed characterization of ALDH+ cells has been addressed by one single study (Gentry et al, 2007. The goal of our work was to provide new information about the dissection of normal bone marrow progenitor cells based upon the simultaneous detection by flow cytometry of ALDH and early hematopoietic antigens, with particular attention to the expression of ALDH on erythroid precursors. To this aim, we used three kinds of approach: i multidimensional analytical flow cytometry, detecting ALDH and early hematopoietic antigens in normal bone marrow; ii fluorescence activated cell sorting of distinct subpopulations of progenitor cells, followed by in vitro induction of erythroid differentiation; iii detection of ALDH+ cellular subsets in bone marrow from pure red cell aplasia patients. Results In normal bone marrow, we identified three populations of cells, namely ALDH+CD34+, ALDH-CD34+ and ALDH+CD34- (median percentages were 0.52, 0.53 and 0.57, respectively. As compared to ALDH-CD34+ cells, ALDH+CD34+ cells expressed the phenotypic profile of primitive hematopoietic progenitor cells, with brighter expression of CD117 and CD133, accompanied by lower display of CD38 and CD45RA. Of interest, ALDH+CD34- population disclosed a straightforward erythroid commitment, on the basis of three orders of evidences. First of all, ALDH+CD34- cells showed a CD71bright, CD105+, CD45- phenotype. Secondly, induction of differentiation experiments evidenced a clear-cut expression of glycophorin A (CD235a. Finally, ALDH+CD34- precursors were not detectable in patients with pure red cell aplasia (PRCA. Conclusion Our study, comparing surface antigen expression of

  7. A comparative study of stool antigen Immunocard STAT HpSA test with biopsy in diagnosis of H Pylori Infection

    Directory of Open Access Journals (Sweden)

    Munish Rastogi

    2015-12-01

    Full Text Available The present study was conducted on 78 cases in the Department of Medicine at G.S.V.M Medical College, Kanpur who reported with various gastrointestinal symptoms such as dyspepsia, heartburns, nausea, vomiting and loss of appetite. They all were advised for biopsy by the physician. Patients treated with antibiotics, bismuth or proton pump inhibitors within 4 weeks preceding the study were excluded. Invasive tests using mucosal biopsies including histology and rapid urease test (RUT were used to establish the gold standard in order to evaluate the accuracy of Immunocard STAT HpSA. Sensitivity, Specificity, Positive Predictive Value and Negative Predictive Value of Immunocard STAT HpSA as compared to gold standard were 95.5%, 81.8%, 96.9% and 75.0% respectively. It is thus concluded that the Immunocard STAT HpSA test has a diagnostic value comparable to the gold standard in detecting H Pylori. The sensitivity and specificity of the test is fair enough to be used as a test for screening purpose and also for diagnosis and treatment of H.Pylori infection in clinical practice

  8. Microradioimmunoassay for antibodies to tumor-associated antigens

    International Nuclear Information System (INIS)

    Huang, J.C.C.; Berczi, I.; Froese, G.; Tsay, H.M.; Sehon, A.H.

    1975-01-01

    A versatile microradioimmunoassay for the detection of antibodies to tumor-associated and other tissue antigens was described. The method involved: the preparation of solid-phase antigen with cultured (already adhered) or noncultured cells (sedimented by centrifugation) fixed to Micro-Test plates with neutral buffered formaldehyde or absolute methanol; the incubation of the antigen with test or control sera; and the incubation of the antigen with radioiodinated antiglobulin antibody. The nonspecific background of radioactivity was reduced to an acceptable level by the fixed cells being precoated in the wells with 0.5 percent bovine serum albumin in phosphate-buffered saline which was also used for the dilution of sera and labeled antiglobulin antibody. Tumor cells in primary cultures gave a high background, as compared to long-term cultures, which was due to the presence of immunoglobulins (most likely tumor-specific antibody). The specific antibody response to a syngeneic mouse tumor was demonstrated by this technique. (auth)

  9. Quench detection electronics testing protocol for SST-1 magnets

    International Nuclear Information System (INIS)

    Banaudha, Moni; Varmora, Pankaj; Parghi, Bhadresh; Prasad, Upendra

    2017-01-01

    Quench Detection (QD) system consisting 204 signal channels has been successfully installed and working well during plasma experiment of SST-1 Tokamak. QD system requires testing, validation and maintenance in every SST-1 campaign for better reliability and maintainability of the system. Standalone test of each channel of the system is essential for hard-ware validation. The standard Testing Protocol follow in every campaign which validate each section of QD electronics as well as voltage tap signal cables which are routed inside the cryostat and then extended outside of the SST-1 machine up-to the magnet control room. Fiber link for Quench signal transmission to the SST-1 magnet power supply is also test and validate before every plasma campaign. Precise instrument used as a dummy source of quench signal and for manual quench generation to test the each channel and Master Quench Logic. Each signal Integrated with the magnet DAQ system, signal observed at 1Hz and 50Hz configuration to validate the logging data, compare with actual and previous test data. This paper describes the testing protocol follow in every campaign to validate functionality of QD electronics, limitation of testing, test results and overall integration of the quench detection system for SST-1 magnet. (author)

  10. Detection of gonococcal infection : pros and cons of a rapid test.

    Science.gov (United States)

    Vickerman, Peter; Peeling, Rosanna W; Watts, Charlotte; Mabey, David

    2005-01-01

    WHO estimates that 62 million cases of gonorrhea occur annually worldwide. Untreated infection can cause serious long-term complications, especially in women. In addition, Neisseria gonorrheae infection can facilitate HIV transmission, and babies born to infected mothers are at risk of ocular infection, which can lead to blindness. Where diagnostic facilities are lacking, gonorrhea can be treated syndromically. However, this inevitably leads to over-treatment, especially in women in whom the syndrome of vaginal discharge may be due not to N. gonorrheae infection but to several other more prevalent conditions. Over-treatment is a major concern because of widespread N. gonorrheae antibiotic resistance. Moreover, a high proportion of gonorrhea cases are asymptomatic and so do not present for syndromic management. Such cases will only be detected by screening tests. The gold standard test for the detection of N. gonorrheae is culture, which has high sensitivity and specificity. However, it requires well trained staff and its performance is affected by specimen transport conditions. Other options include microscopy and tests that detect gonococcal antigen or nucleic acid. Nucleic acid amplification tests (NAATs) have higher sensitivity and can be used on non-invasive samples (urine). However, they can cross-react with other Neisseria species and are expensive, requiring highly trained staff and sophisticated equipment. In settings where patients are asked to return for laboratory results, some infected patients never receive treatment as they fail to return for their test results. This reduction in treatment, and the possible onward transmission of N. gonorrheae during any delay in treatment, means that a rapid test of lower sensitivity may be more effective if it results in patients being treated at the initial visit. Indeed, even with the low sensitivity of currently available rapid tests (50-70%), modeling shows that they can outperform gold standard tests in

  11. Real time risk analysis of kick detection: Testing and validation

    International Nuclear Information System (INIS)

    Islam, Rakibul; Khan, Faisal; Venkatesan, Ramchandran

    2017-01-01

    Oil and gas development is moving into harsh and remote locations where the highest level of safety is required. A blowout is one of the most feared accidents in oil and gas developments projects. The main objective of this paper is to test and validate the kick detection of blowout risk assessment model using uniquely developed experimental results. Kick detection is a major part of the blowout risk assessment model. The accuracy and timeliness of kick detection are dependent on the monitoring of multiple downhole parameters such as downhole pressure, fluid density, fluid conductivity and mass flow rate. In the present study these four parameters are considered in different logical combinations to assess the occurrence of kick and associated blowout risk. The assessed results are compared against the experimental observations. It is observed that simultaneous monitoring of mass flow rate combined with any one the three parameters provides most reliable detection of kick and potential blowout likelihood. The current work presents the framework for a dynamic risk assessment and management model. Upon success testing of this approach at the pilot and field levels, this approach could provide a paradigm shift in drilling safety. - Highlights: • A novel dynamic risk model of kick detection and blowout prediction. • Testing and Validation of the risk model. • Application of the dynamic risk model.

  12. Memory detection 2.0: the first web-based memory detection test.

    Science.gov (United States)

    Kleinberg, Bennett; Verschuere, Bruno

    2015-01-01

    There is accumulating evidence that reaction times (RTs) can be used to detect recognition of critical (e.g., crime) information. A limitation of this research base is its reliance upon small samples (average n = 24), and indications of publication bias. To advance RT-based memory detection, we report upon the development of the first web-based memory detection test. Participants in this research (Study1: n = 255; Study2: n = 262) tried to hide 2 high salient (birthday, country of origin) and 2 low salient (favourite colour, favourite animal) autobiographical details. RTs allowed to detect concealed autobiographical information, and this, as predicted, more successfully so than error rates, and for high salient than for low salient items. While much remains to be learned, memory detection 2.0 seems to offer an interesting new platform to efficiently and validly conduct RT-based memory detection research.

  13. Memory detection 2.0: the first web-based memory detection test.

    Directory of Open Access Journals (Sweden)

    Bennett Kleinberg

    Full Text Available There is accumulating evidence that reaction times (RTs can be used to detect recognition of critical (e.g., crime information. A limitation of this research base is its reliance upon small samples (average n = 24, and indications of publication bias. To advance RT-based memory detection, we report upon the development of the first web-based memory detection test. Participants in this research (Study1: n = 255; Study2: n = 2