WorldWideScience

Sample records for antibody enzyme immunoassay

  1. Design of a single-step immunoassay principle based on the combination of an enzyme-labeled antibody release coating and a hydrogel copolymerized with a fluorescent enzyme substrate in a microfluidic capillary device.

    Science.gov (United States)

    Wakayama, Hideki; Henares, Terence G; Jigawa, Kaede; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki

    2013-11-21

    A combination of an enzyme-labeled antibody release coating and a novel fluorescent enzyme substrate-copolymerized hydrogel in a microchannel for a single-step, no-wash microfluidic immunoassay is demonstrated. This hydrogel discriminates the free enzyme-conjugated antibody from an antigen-enzyme-conjugated antibody immunocomplex based on the difference in molecular size. A selective and sensitive immunoassay, with 10-1000 ng mL(-1) linear range, is reported.

  2. Quantification of patient specific assay interference in different formats of enzyme linked immunoassays for therapeutic monoclonal antibodies

    NARCIS (Netherlands)

    Grebenchtchikov, N.J.; Geurts-Moespot, A.; Heijmen, L.; Laarhoven, H.W.M. van; Herpen, C.M.L. van; Thijs, A.M.J.; Span, P.N.; Sweep, F.C.

    2014-01-01

    BackgroundThe use of therapeutic monoclonal antibodies for clinical purposes has significantly increased in recent years, and so has the need to monitor antibody concentrations. This may be achieved using the well-established enzyme linked immunoassay (ELISA) methods; however, these assays are

  3. Quantification of patient-specific assay interference in different formats of enzyme-linked immunoassays for therapeutic monoclonal antibodies

    NARCIS (Netherlands)

    Grebenchtchikov, Nicolai; Geurts-Moespot, Anneke J.; Heijmen, Linda; van Laarhoven, Hanneke W. M.; van Herpen, Carla M. L.; Thijs, Annemarie M. J.; Span, Paul N.; Sweep, Fred C. G. J.

    2014-01-01

    The use of therapeutic monoclonal antibodies for clinical purposes has significantly increased in recent years, and so has the need to monitor antibody concentrations. This may be achieved using the well-established enzyme linked immunoassay (ELISA) methods; however, these assays are subject to a

  4. A sandwich immunoassay for human prolyl 4-hydroxylase using monoclonal antibody

    International Nuclear Information System (INIS)

    Yoshida, Shinichi

    1986-01-01

    Monoclonal antibody was used in a sandwich enzyme immunoassay and in a radioimmunoassay for human serum immunoreactive prolyl 4-hydroxylase. The enzyme immunoassay utilized a monoclonal antibody as a solid phase and horseradish peroxidase-labeled rabbit antibody to human prolyl 4-hydroxylase as a conjugate. Sensitivity was 0.1 ng of enzyme per tube. With a conjugate purified by an enzyme-bound affinity column, sensitivity was increased to 0.01 ng per tube, and linearity was obtained between 0.01 to 30 ng per tube. The radioimmunoassay used a 125 I-labeled rabbit antibody (IgG) as the conjugate. Sensitivity of this technique was 0.4 ng of enzyme per tube. (Auth.)

  5. [Automated analyzer of enzyme immunoassay].

    Science.gov (United States)

    Osawa, S

    1995-09-01

    Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.

  6. Development and application of radioimmunoassay and enzyme immunoassays in microbiological and immunological diagnosis. 3. Comparative studies for the detection of virus antibodies with passive hemagglutination test, radioimmunoassay and enzyme immunoassay, resp

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, H; Struy, H; Morenz, J [Medizinische Akademie, Magdeburg (German Democratic Republic)

    1982-06-01

    Radioimmuno- and enzyme immunoassays (solid phase RIA and ELISA) developed by the authors for the determination of antibodies of adeno-2- and parainfluenza-1-viruses are described and the detection sensibility for antibodies is compared with that of the conventional passive hemagglutination test. The sensibility of the radioimmunoassay for the detection of IgG antibodies against adeno-2-viruses is nearly 10 times higher than that of the passive hemagglutination. RIA and ELISA show no essential differences in their detection sensibilities in the detection of IgG antibodies against parainfluenza-1-viruses.

  7. Development of a novel ultrasensitive enzyme immunoassay for human glutamic acid decarboxylase 65 antibody.

    Science.gov (United States)

    Numata, Satoshi; Katakami, Hideki; Inoue, Shinobu; Sawada, Hirotake; Hashida, Seiichi

    2016-07-01

    We developed a novel, ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for determination of glutamic acid decarboxylase autoantibody concentrations in serum samples from patients with type 2 diabetes. We developed an immune complex transfer enzyme immunoassay for glutamic acid decarboxylase autoantibody and measured glutamic acid decarboxylase autoantibody from 22 patients with type 1 diabetes, 29 patients with type 2 diabetes, and 32 healthy controls. A conventional ELISA kit identified 10 patients with type 1 diabetes and one patient with type 2 diabetes as glutamic acid decarboxylase autoantibody positive, whereas 15 patients with type 1 diabetes and six patients with type 2 diabetes were identified as glutamic acid decarboxylase autoantibody positive using immune complex transfer enzyme immunoassay. Immune complex transfer enzyme immunoassay is a highly sensitive and specific assay for glutamic acid decarboxylase autoantibody and might be clinically useful for diabetic onset prediction and early diagnosis. © The Author(s) 2016.

  8. Plasma exchange to remove HIT antibodies: dissociation between enzyme-immunoassay and platelet activation test reactivities.

    Science.gov (United States)

    Warkentin, Theodore E; Sheppard, Jo-Ann I; Chu, F Victor; Kapoor, Anil; Crowther, Mark A; Gangji, Azim

    2015-01-01

    Repeated therapeutic plasma exchange (TPE) has been advocated to remove heparin-induced thrombocytopenia (HIT) IgG antibodies before cardiac/vascular surgery in patients who have serologically-confirmed acute or subacute HIT; for this situation, a negative platelet activation assay (eg, platelet serotonin-release assay [SRA]) has been recommended as the target serological end point to permit safe surgery. We compared reactivities in the SRA and an anti-PF4/heparin IgG-specific enzyme immunoassay (EIA), testing serial serum samples in a patient with recent (subacute) HIT who underwent serial TPE precardiac surgery, as well as for 15 other serially-diluted HIT sera. We observed that post-TPE/diluted HIT sera-when first testing SRA-negative-continue to test strongly positive by EIA-IgG. This dissociation between the platelet activation assay and a PF4-dependent immunoassay for HIT antibodies indicates that patients with subacute HIT undergoing repeated TPE before heparin reexposure should be tested by serial platelet activation assays even when their EIAs remain strongly positive. © 2015 by The American Society of Hematology.

  9. The significance for epidemiological studies anti-measles antibody detection examined by enzyme immunoassay (EIA) and plaque reduction neutralization test (PRNT).

    Science.gov (United States)

    Siennicka, Joanna; Częścik, Agnieszka; Trzcińska, Agnieszka

    2014-01-01

    The paper discusses the role of anti-measles antibodies for protection and significance for epidemiological studies determination of antibodies by different serological methods. The comparison of anti-measles virus antibodies levels measured by enzyme immunoassay (EIA) and Plaque Reduction Neutralization Test (PRNT) was described. It was found that the 200 mIU/ml of anti-measles activity measured by PRNT (level protection against symp- tomatic disease) is equivalent of 636 mIU/ml measured by EIA (Enzygnost®Anti-Measles Virus/IgG, Simens).

  10. Enhanced immunoassay for porcine circovirus type 2 antibody using enzyme-loaded and quantum dots-embedded shell–core silica nanospheres based on enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Wu, Long; Li, Xuepu; Shao, Kang; Ye, Shiyi; Liu, Chen; Zhang, Chenjun; Han, Heyou

    2015-01-01

    Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL −1 with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics. - Highlights: • A versatile ELISA-based immunoassay for PCV2 antibody was developed. • Enzyme and CdSe QDs modified SiO 2 particles were used to improve sensitivity. • The simultaneous three ELISA-based techniques enhanced the detection reliability. • The biosensors strategy could provide a new avenue to ELISA-based sensors

  11. Enhanced immunoassay for porcine circovirus type 2 antibody using enzyme-loaded and quantum dots-embedded shell–core silica nanospheres based on enzyme-linked immunosorbent assay

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Long; Li, Xuepu; Shao, Kang; Ye, Shiyi; Liu, Chen; Zhang, Chenjun; Han, Heyou, E-mail: hyhan@mail.hzau.edu.cn

    2015-08-05

    Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL{sup −1} with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics. - Highlights: • A versatile ELISA-based immunoassay for PCV2 antibody was developed. • Enzyme and CdSe QDs modified SiO{sub 2} particles were used to improve sensitivity. • The simultaneous three ELISA-based techniques enhanced the detection reliability. • The biosensors strategy could provide a new avenue to ELISA-based sensors.

  12. Monoclonal antibody-based immunoassays.

    Science.gov (United States)

    Appleby, P; Reischl, U

    1998-01-01

    An immunoassay may be defined as an assay that employs an immunological reagent, usually an antibody, to confer specificity for the ligand being measured. As a corollary to this, the discovery, and subsequent development, of monoclonal antibodies (MAbs) has greatly expanded the application and use of immunoassays. Polyclonal reagents, with their associated problems of specificity and quality control, have now been largely replaced by readily available MAbs of potential immortality and well-defined specificity and affinity. This has resulted, in the last two decades, in a great expansion in the range of immunoassays available and also a significant improvement in their reproducibility and reliability.

  13. Novel enzyme immunoassay system for simultaneous detection of six subclasses of antiphospholipid antibodies for differential diagnosis of antiphospholipid syndrome.

    Science.gov (United States)

    Nojima, Junzo; Motoki, Yukari; Hara, Kazusa; Sakata, Toshiyuki; Ichihara, Kiyoshi

    2017-06-01

    : Antiphospholipid syndrome, which often complicates systemic lupus erythematosus (SLE), features high occurrence of arterial and/or venous thrombosis and recurrent fetal loss. However, which antibody subclass contributes to which clinical event remains uncertain. We newly developed an up-to-date enzyme immunoassay system using the AcuStar automated analyzer (Instrumentation Laboratory, Bedford, Massachusetts, USA) for parallel detection of six subclasses of antiphospholipid antibodies (aPLs): anticardiolipin antibodies (aCL) of IgG, IgM, and IgA and anti-β2-glycoprotein I antibodies (aβ2GPI) of IgG, IgM, and IgA. They were measured in 276 healthy volunteers and 138 patients with SLE: 45 with thromboembolic complications (29 arterial; 16 venous) and 93 without. Lupus anticoagulant activity in their plasma was measured according to the guidelines recommended by the Subcommittee on Lupus Anticoagulant/Phospholipid-Dependent Antibodies. aCL/β2GPI was measured with a standard ELISA kit commonly used in Japan. The positive results of IgG aCL, IgA aCL, and IgG aβ2GPI were closely associated with thromboembolic complications, whereas IgM aCL and IgM aβ2GPI were not. receiver operating characteristic analysis revealed that the accuracy of predicting thromboembolic complications based on the composite test results of the former three antibodies were obviously higher than by each alone. Regarding agreement with the test results of lupus anticoagulant activity, IgG aβ2GPI showed the closest match. Patients with SLE frequently possess various combinations of the six aPL subclasses, and this antibody spectrum is closely associated with thromboembolic events in these patients. This new automated enzyme immunoassay system allows simultaneous analysis of the profile of aPL subclasses for the differential diagnosis of antiphospholipid antibody syndrome in its early stage.

  14. Enzyme immunoassay for rabies antibody in hybridoma culture fluids and its application to differentiation of street and laboratory strains of rabies virus.

    OpenAIRE

    Smith, J S; Sumner, J W; Roumillat, L F

    1984-01-01

    A rapid and sensitive enzyme immunoassay is described for detecting rabies antibody in hybridoma culture fluids. Glass fiber filter disks were used to immobilize gamma-irradiated mouse neuroblastoma cells infected with street or laboratory strains of rabies virus. Bound rabies-specific antibody was detected by reaction with horseradish peroxidase-labeled goat anti-mouse immunoglobulin G. The assay was performed in a 96-well filtration device developed by Cleveland et al. (J. Clin. Microbiol. ...

  15. Multicentric Evaluation of New Commercial Enzyme Immunoassays for the Detection of Immunoglobulin M and Total Antibodies against Hepatitis A Virus▿

    Science.gov (United States)

    Arcangeletti, M. C.; Dussaix, E.; Ferraglia, F.; Roque-Afonso, A. M.; Graube, A.; Chezzi, C.

    2011-01-01

    A multicentric clinical study was conducted on representative sera from 1,738 European and U.S. subjects for the evaluation of new anti-hepatitis A virus enzyme immunoassays from Bio-Rad Laboratories. Comparison with reference DiaSorin S.p.A. tests confirmed the good performance of Bio-Rad assays (99.85% and 99.47% overall agreement in detecting total antibodies and IgM, respectively). PMID:21653739

  16. Evaluation of six immunoassays for detection of dengue virus-specific immunoglobulin M and G antibodies

    NARCIS (Netherlands)

    J. Groen (Jan); P. Koraka (Penelope); J. Velzing (Jans); C. Copra (Cederick); A.D.M.E. Osterhaus (Albert)

    2000-01-01

    textabstractThe performance of six commercially available immunoassay systems for the detection of dengue virus-specific immunoglobulin M (IgM) and IgG antibodies in serum was evaluated. These included two IgM and IgG enzyme immunoassays (EIA) from MRL Laboratories and PanBio, a rapid

  17. Molecularly Imprinted Polymer as an Antibody Substitution in Pseudo-immunoassays for Chemical Contaminants in Food and Environmental Samples.

    Science.gov (United States)

    Chen, Chaochao; Luo, Jiaxun; Li, Chenglong; Ma, Mingfang; Yu, Wenbo; Shen, Jianzhong; Wang, Zhanhui

    2018-03-21

    The chemical contaminants in food and the environment are quite harmful to food safety and human health. Rapid, accurate, and cheap detection can effectively control the potential risks derived from these chemical contaminants. Among all detection methods, the immunoassay based on the specific interaction of antibody-analyte is one of the most widely used techniques in the field. However, biological antibodies employed in the immunoassay usually cannot tolerate extreme conditions, resulting in an unstable state in both physical and chemical profiles. Molecularly imprinted polymers (MIPs) are a class of polymers with specific molecular recognition abilities, which are highly robust, showing excellent operational stability under a wide variety of conditions. Recently, MIPs have been used in biomimetic immunoassays for chemical contaminants as an antibody substitute in food and the environment. Here, we reviewed these applications of MIPs incorporated in different analytical platforms, such as enzyme-linked immunosorbent assay, fluorescent immunoassay, chemiluminescent immunoassay, electrochemical immunoassay, microfluidic paper-based immunoassay, and homogeneous immunoassay, and discussed current challenges and future trends in the use of MIPs in biomimetic immunoassays.

  18. [Establishment of chemiluminescent enzyme immunoassay for detecting antibodies against foot-and-mouth disease virus serotype O in swine].

    Science.gov (United States)

    Cui, Chen; Huang, Ligang; Li, Jing; Zou, Xingqi; Zhu, Yuanyuan; Xie, Lei; Zhao, Qizu; Yang, Limin; Liu, Wenjun

    2016-11-25

    Recombinant structural protein VP1 of foot-and-mouth disease virus serotype O was expressed in Escherichia coli and then purified using Nickel affinity chromatography. A chemiluminescent enzyme immunoassay (CLEIA) method was established using the purified recombinant protein as coating antigen to detect antibody of foot-and-mouth disease virus serotype O in swine. The specificity of VP1-CLEIA method is 100%. The coefficients of variation in the plate and between plates are 1.10%-6.70% and 0.66%-4.80%, respectively. Comparing with the commercial indirect ELISA kit or liquid phase block ELISA kit, the calculated coincidence rate is 93.50% or 94.00%. The high specificity and stability suggested this detection method can be used to monitor the antibody level of foot-and-mouth disease virus serotype O in swine.

  19. Competitive enzyme immunoassay for human chorionic somatomammotropin using the avidin-biotin system

    International Nuclear Information System (INIS)

    Rappuoli, R.; Leoncini, P.; Tarli, P.; Neri, P.

    1981-01-01

    Human chorionic somatomammotropin (HCS) is determined by an enzyme immunoassay where HCS competes with biotin-labeled HCS for insolubilized anti-HCS antibodies. Enzyme-labeled avidin is then used to reveal the amount of bound HCS. The system proves to be sensitive (1 ng/ml of HCS can be detected) and results agree with radioimmunoassay determinations (correlation coefficient = 0.979). Kinetics of the avidin-biotin reaction and coating of polystyrene wells are also investigated

  20. Review of the biochemical basis of enzyme immunoassays

    International Nuclear Information System (INIS)

    Klingler, W.

    1982-01-01

    The ever increasing number of radioimmunological determination poses problems allied with the handling of radioactive substances. In recent years various non-radioactive methods have been developed, among which the enzyme immunoassay is already in routine use. Homogeneous and heterogeneous enzyme immunoassays are described. Criteria for enzymes, substrates and enzyme-substrate reactions are listed. (orig.) [de

  1. Survey of immunoassay techniques for biological analysis

    International Nuclear Information System (INIS)

    Burtis, C.A.

    1986-10-01

    Immunoassay is a very specific, sensitive, and widely applicable analytical technique. Recent advances in genetic engineering have led to the development of monoclonal antibodies which further improves the specificity of immunoassays. Originally, radioisotopes were used to label the antigens and antibodies used in immunoassays. However, in the last decade, numerous types of immunoassays have been developed which utilize enzymes and fluorescent dyes as labels. Given the technical, safety, health, and disposal problems associated with using radioisotopes, immunoassays that utilize the enzyme and fluorescent labels are rapidly replacing those using radioisotope labels. These newer techniques are as sensitive, are easily automated, have stable reagents, and do not have a disposal problem. 6 refs., 1 fig., 2 tabs

  2. Detection of hidden hazelnut protein in food by IgY-based indirect competitive enzyme-immunoassay

    NARCIS (Netherlands)

    Baumgartner, S.; Bremer, M.G.E.G.; Kemmers - Voncken, A.E.M.; Smits, N.G.E.; Haasnoot, W.; Banks, J.; Reece, P.; Danks, C.; Tomkies, V.; Immer, U.; Schmitt, K.; Krska, R.

    2004-01-01

    The development of an indirect competitive enzyme-immunoassay for the detection of hidden hazelnut protein in complex food matrices is described. A sensitive and selective polyclonal antibody was raised by immunisation of laying hens with protein extracts from roasted hazelnuts. In contrast to

  3. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    OpenAIRE

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of th...

  4. Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing

    OpenAIRE

    Halling, V. W.; Jones, M. F.; Bestrom, J. E.; Wold, A. D.; Rosenblatt, J. E.; Smith, T. F.; Cockerill, F. R.

    1999-01-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTI...

  5. [Use of monoclonal antibodies against horse immunoglobulin in an enzyme immunoassay of bacterial toxins and anatoxins].

    Science.gov (United States)

    Burkin, M A; Gal'vidis, I A; Iakovleva, I V; Sviridov, V V

    2007-01-01

    Immunization of BALB/c mice by horse antiserum against diphtheria made it possible to obtain IgG1 monoclonal antibodies (MoAbs) 2B7E4 specific for light chains of horse immunoglobulin (Ig). Unlike commercial preparations of anti-horse immunoglobulin antibodies, which are specific for the whole Ig molecule or its Fc-fragment, the peroxidase (HRP) conjugate of the MoAb, 2B7E4-HRP did not interact with human, mouse, rabbit, and sheep Igs, or horse albumin. The conjugate obtained was used with MoAbs against bacterial toxins and commercial horse anatoxins, as a universal reagent in sandwich enzyme immunoassay (ELISA) for bacterial toxins and anatoxins. The detection sensitivity of diphtheria toxin/anatoxin equaled 0.0005 Lf/ml; tetanus toxin and anatoxin were detected with sensitivities of 20 LD50/ml and 0.005 UI/ml, respectively. A similar sandwich ELISA for botulinum anatoxins (group measurement) allowed types A, B, and E to be detected at 0.02, 0.002, and 0.001 UI/ml, respectively; selective measurement was only possible in the case of type E anatoxin (0.001 UI/ml).

  6. Specificity of immunoassays. Pt. 2

    International Nuclear Information System (INIS)

    Pratt, J.J.; Woldring, M.G.; Boonman, R.; Kittikool, J.

    1979-01-01

    Practical aspects of the measurement of the specificity of immunoassay are reviewed. Antibody heterogeneity in an antiserum makes a pragmatic rather than a theoretical approach necessary. A new method for the measurement of immunoassay specificity is described. This method is based on the errors caused by the cross-reacting antigens and is directly relevant to the validity of results obtained by immunoassay methods. The effect of selectively blocking the least specific antibodies in antisera raised against steroid haptens is tested. The practical consequences of these considerations are tested using steroid radioimmunoassay and enzyme-immunoassay. (orig.) [de

  7. Summary of field trials using the direct and competitive enzyme immunoassays for detection of antibody to brucella abortus

    International Nuclear Information System (INIS)

    Nielsen, K.; Gall, D.

    1998-01-01

    Two indirect and two competitive enzyme immunoassays for detection of antibody to Brucella abortus, validated elsewhere, were field tested in five different Latin American laboratories. Testing was performed according to standardised protocols using sera obtained in each area. Sera from B. abortus infected herds, from vaccinated (but serologically negative in a screening test) and non-vaccinated cattle were tested in each assay and compared to the results obtained with conventional diagnostic tests used for diagnosis of brucellosis in each country. Relative sensitivity and specificity values were calculated for each country as well as a weighted summary combining the data from all the participating laboratories. The result demonstrate that all ELISAs performed as well as, or better than, the conventional aerological tests. Given the inherent errors in the use of the latter in the diagnosis of brucellosis, it is recommended that the ELISAs described here be considered as replacements for the conventional tests. The CELISA using the lipopolysaccharide antigen with the competing monoclonal antibody M84, should be considered as the most useful because of cross-species and vaccination considerations. (author)

  8. Nanoparticle-based sandwich electrochemical immunoassay for carbohydrate antigen 125 with signal enhancement using enzyme-coated nanometer-sized enzyme-doped silica beads.

    Science.gov (United States)

    Tang, Dianping; Su, Biling; Tang, Juan; Ren, Jingjing; Chen, Guonan

    2010-02-15

    A novel nanoparticle-based electrochemical immunoassay of carbohydrate antigen 125 (CA125) as a model was designed to couple with a microfluidic strategy using anti-CA125-functionalized magnetic beads as immunosensing probes. To construct the immunoassay, thionine-horseradish peroxidase conjugation (TH-HRP) was initially doped into nanosilica particles using the reverse micelle method, and then HRP-labeled anti-CA125 antibodies (HRP-anti-CA125) were bound onto the surface of the synthesized nanoparticles, which were used as recognition elements. Different from conventional nanoparticle-based electrochemical immunoassays, the recognition elements of the immunoassay simultaneously contained electron mediator and enzyme labels and simplified the electrochemical measurement process. The sandwich-type immunoassay format was used for the online formation of the immunocomplex in an incubation cell and captured in the detection cell with an external magnet. The electrochemical signals derived from the carried HRP toward the reduction of H(2)O(2) using the doped thionine as electron mediator. Under optimal conditions, the electrochemical immunoassay exhibited a wide working range from 0.1 to 450 U/mL with a detection limit of 0.1 U/mL CA125. The precision, reproducibility, and stability of the immunoassay were acceptable. The assay was evaluated for clinical serum samples, receiving in excellent accordance with results obtained from the standard enzyme-linked immunosorbent assay (ELISA) method. Concluding, the nanoparticle-based assay format provides a promising approach in clinical application and thus represents a versatile detection method.

  9. Enzyme immunoassay of oestrogen receptors in needle biopsies from human liver

    DEFF Research Database (Denmark)

    Becker, U; Andersen, J; Poulsen, H S

    1991-01-01

    For quantitative assessments of sex hormone receptors in liver tissue, ligand binding assays are inconvenient, as they require large biopsies (0.5-1.0 g). The present study shows that it is possible to measure oestrogen receptors (ER) quantitatively in needle biopsy specimens as small as 10 mg...... by modifications of a commercial enzyme immunoassay employing monoclonal antibodies. Sucrose gradient centrifugation and the dextran charcoal method served as reference methods. A consecutive series of needle biopsies from patients suspected of liver disease were investigated. The biopsies (n = 37) had a median...

  10. Heparin interferes with the radioenzymatic and homogeneous enzyme immunoassays for aminoglycosides

    International Nuclear Information System (INIS)

    Krogstad, D.J.; Granich, G.G.; Murray, P.R.; Pfaller, M.A.; Valdes, R.

    1981-01-01

    Heparin interferes with measurement of aminoglycosides in serum by biological, radioenzymatic, and homogeneous enzyme immunoassay techniques, but not with radioimmunoassay. At concentrations greater than or equal to 10 5 and greater than or equal to 3 X 10 6 USP units/L, respectively, it interferes with the radioenzymatic assay by inhibiting the gentamicin 3-acetyltransferase and kanamycin 6'-acetyltransferase enzymes used in the assay. It interferes with the homogeneous enzyme immunoassays for gentamicin and tobramycin (at concentrations greater than or equal to 10 5 and greater than or equal to10 4 USP units/L, respectively), but not with the commercially available homogeneous enzyme immunoassays for other drugs. Heparin interference with the homogeneous enzyme immunoassay for aminoglycosides requires both the heparin polyanion and glucose-6-phosphate dehydrogenase bound to a cationic aminoglycoside. This interference can be reproduced with dextran sulfate (but not dextran), and does not occur with free enzyme (glucose-6-phosphate dehydrogenase) alone. Heparin interference with these two assays and at concentrations that may be present in intravenous infusions or in seriously underfilled blood-collection tubes is described

  11. Developments of sensitive immunoassays for detection of antibodies against hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Ionescu-Matiu, I; Sanchez, Y; Dreesman, G R [Baylor Univ., Houston, TX (USA). Coll. of Medicine; Fields, H A [Centers for Disease Control, Public Health Service, Department of Health and Human Services, Phoenix, AZ (USA)

    1983-01-01

    Three micro solid phase immunoassays (a micro-SPRIA and two ELISA techniques) were developed and tested for the detection of anti-HBs antibodies. Two different crosslinkers (glutaraldehyde and N-succinimidyl 3-(2-pyridyldithio) propionate) were used to couple a goat anti-mouse IgG reagent to alkaline phosphatase for use as enzyme-labeled probes in the two ELISA tests. With the latter cross-linker, a defined conjugate with a 1 : 1 antibody-enzyme molar ratio was obtained. The sensitivities of micro-SPRIA and the two types of ELISA were compared to that of the commercial solid phase radioimmunoassay AUSAB test. All three microtests were significantly more sensitive than the AUSAB test. The ELISA using the glutaraldehyde cross-linked conjugate was 3-5 times less sensitive than micro-SPRIA, while the ELISA using the disulfide-linked conjugate was 2.6-4.0 times more sensitive than micro-SPRIA.

  12. Chimeric recombinant antibody fragments in cardiac troponin I immunoassay.

    Science.gov (United States)

    Hyytiä, Heidi; Heikkilä, Taina; Brockmann, Eeva-Christine; Kekki, Henna; Hedberg, Pirjo; Puolakanaho, Tarja; Lövgren, Timo; Pettersson, Kim

    2015-03-01

    To introduce a novel nanoparticle-based immunoassay for cardiac troponin I (cTnI) utilizing chimeric antibody fragments and to demonstrate that removal of antibody Fc-part and antibody chimerization decrease matrix related interferences. A sandwich-type immunoassay for cTnI based on recombinant chimeric (mouse variable/human constant) antigen binding (cFab) antibodies and intrinsically fluorescent nanoparticles was developed. To test whether using chimeric antibody fragments helps to avoid matrix related interferences, samples (n=39) with known amounts of triglycerides, bilirubin, rheumatoid factor (RF) or human anti-mouse antibodies (HAMAs) were measured with the novel assay, along with a previously published nanoparticle-based research assay with the same antibody epitopes. The limit of detection (LoD) was 3.30ng/L. Within-laboratory precision for 29ng/L and 2819ng/L cTnI were 13.7% and 15.9%, respectively. Regression analysis with Siemens ADVIA Centaur® yielded a slope (95% confidence intervals) of 0.18 (0.17-1.19) and a y-intercept of 1.94 (-1.28-3.91) ng/L. When compared to a previously published nanoparticle-based assay, the novel assay showed substantially reduced interference in the tested interference prone samples, 15.4 vs. 51.3%. A rheumatoid factor containing sample was decreased from 241ng/L to immunoassay for the detection of cTnI and decreased matrix related interferences, thus resulting in a lower number of falsely elevated cTnI-values. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Radiolabelling for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Since the early 1960s labelled compounds employed in immunoassay techniques, both radioimmunoassay and immunoradiometric assay, have involved radioisotopes typically 3 H (tritium) and 125 Iodine. With the advent of increasingly stringent governmental regulations regarding usage and disposal of radioisotopes and the impetus of research towards improved immunoassay sensitivity following the discovery of monoclonal antibodies and their application to excess reagent immunometric assay methodology, radioisotopic labels are gradually being replaced by non-isotopic labels: enzyme, fluorescence and chemiluminescence

  14. Determining total thyroxine with the aid of the homogeneous enzyme immunoassay

    International Nuclear Information System (INIS)

    Vogt, W.

    1978-01-01

    Total thyrozine values obtained with the aid of the homogeneous enzyme immunoassay are compared with those delivered by the RIA and the efficiency of the EMIT technique is evaluated. Some results obtained via Enzymun-T4, a heterologous enzyme immunoassay, are also given. (VJ) 891 VJ [de

  15. Usefulness of enzyme immunoassay (EIA) for screening of anti HIV antibodies in urinary specimens: A comparative analysis.

    Science.gov (United States)

    Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S

    2014-07-01

    Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.

  16. Comparison of immunoassays for differentiation of herpes simplex virus type 1 and 2 antibodies

    International Nuclear Information System (INIS)

    Klapper, Paul E.; Valley, Pam J.; Cleator, Gerham M.; Mandall, D.; Qutub, Mohammed O.

    2006-01-01

    To asses the commercial available enzyme-linked immunosorbent assays (ELISA) for differentiation of herpes simplex virus type 1 (Hs-1) and type 2 (HSV-2) antibodies. The study was performed between January 1997 to November 2002 in the Division ofVirology,Department of Pathological Sciences, Central Manchester Healthcare Trust and University of Manchester, Manchester, United Kingdom. Assays based upon type-specific glycoprotein G-1 (gG-1) for HSV-1, and glycoprotein G-2 (gG-2) from HSV-2 were evaluated to differentiate between HSV-1 and HSV-2 antibodies. Using 5 different ELISA tests, 2 panels of serum samples were tested. Panel one consisted of 88 sera, selected from the serum bank of the Clinical Virology Laboratory, Manchester Royal Infirmary; panel 2 comprised of 90 sera selected from samples collected from Bangladeshi female commercial workers.The data of this study showed that a high rate of gG-1 based immunoassays ranged from 87.9-100% for sensitivity and 51.5-100% specificity. Although there are several immunoassays were claimed to differentiate between HSV-1 and HSV-2 antibodies, selection of these assays should be carefully interpreted with the overall clinical framework provided by detailed sexual history and genital examination. (author)

  17. Comparison of capillary electrophoresis-based immunoassay with fluorescence polarization immunoassay for the immunodetermination of methamphetamine using various methamphetamine antibodies.

    Science.gov (United States)

    Choi, J; Kim, C; Choi, M J

    1998-11-01

    An accurate and simple immunoassay using capillary electrophoresis (CE) with laser-induced fluorescence (LIF) was performed for the detection of methamphetamine (MA) in urine. The CE-LIF was conducted with an untreated fused-silica column using antiserum and a tracer of fluorescein isothiocyanate (FITC)-labeled MA. This CE-LIF system was compared with fluorescence polarization immunoassay (FPIA) in a TDx analyzer in the photo-check mode using the same FITC-labeled tracer and the same antiserum. Various antibodies, not only those prepared by our own immunogens but also those from commercial sources, were screened and characterized in both assay systems with regard to sensitivity, precision, and cross-reactivity. Both systems satisfied analytical precision and gave similar cross-reactivity patterns. However, the CE-LIF-based immunoassay was approximately one order superior to FPIA in sensitivity, requiring less volume of sample, antiserum, and tracer for the assay. Considering that the FPIA system is well known to be a useful tool for screening antibodies and detecting drugs, the CE-LIF-based immunoassay system, which is seemingly more advantageous than the FPIA system, appears to have great power for the characterization of antibodies and for the detection of MA in urine.

  18. A competitive chemiluminescence enzyme immunoassay for rapid and sensitive determination of enrofloxacin

    Science.gov (United States)

    Yu, Fei; Wu, Yongjun; Yu, Songcheng; Zhang, Huili; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B.

    With alkaline phosphatase (ALP)-adamantane (AMPPD) system as the chemiluminescence (CL) detection system, a highly sensitive, specific and simple competitive chemiluminescence enzyme immunoassay (CLEIA) was developed for the measurement of enrofloxacin (ENR). The physicochemical parameters, such as the chemiluminescent assay mediums, the dilution buffer of ENR-McAb, the volume of dilution buffer, the monoclonal antibody concentration, the incubation time, and other relevant variables of the immunoassay have been optimized. Under the optimal conditions, the detection linear range of 350-1000 pg/mL and the detection limit of 0.24 ng/mL were provided by the proposed method. The relative standard deviations were less than 15% for both intra and inter-assay precision. This method has been successfully applied to determine ENR in spiked samples with the recovery of 103%-96%. It showed that CLEIA was a good potential method in the analysis of residues of veterinary drugs after treatment of related diseases.

  19. Radioimmunoassay and enzyme-linked immunoassay of antibodies directed against lymphadenopathy-associated virus (LAV) proteins larger than the core protein (P24)

    International Nuclear Information System (INIS)

    Neurath, A.R.; Strick, N.; Lee, Y.S.; Nilsen, T.; Baker, L.; Sproul, P.; Rubinstein, P.; Taylor, P.; Stevens, C.E.; Gold, J.W.M.

    1985-01-01

    Molecular exclusion chromatography of crude LAV antigen preparations allows separation of most of P24 from larger proteins of LAV (PL). PL and 125 I- or beta-lactamase-labeled anti-LAV were used as reagents for radioimmunoassay (RIA) - or enzyme-linked immunoassay (ELISA) - inhibition tests to detect antibodies directed predominantly against PL (anti-PL). Among 257 individuals belonging to groups at high risk of developing AIDS, 117 (45.5%) were positive for anti-PL and 108 (42%) for anti-P24, respectively. The 2 individuals among 600 random blood donors found to be anti-P24-positive in the preceding study also had anti-PL in their serum. Sera from 500 additional blood donors were screened for anti-PL and 1 of these was positive. The implication of these findings for screening of blood donors is discussed. (Auth.)

  20. Radioimmunoassay and enzyme-linked immunoassay of antibodies directed against lymphadenopathy-associated virus (LAV) proteins larger than the core protein (P24)

    Energy Technology Data Exchange (ETDEWEB)

    Neurath, A R; Strick, N; Lee, Y S; Nilsen, T; Baker, L; Sproul, P; Rubinstein, P; Taylor, P; Stevens, C E; Gold, J W.M.

    1985-10-01

    Molecular exclusion chromatography of crude LAV antigen preparations allows separation of most of P24 from larger proteins of LAV (PL). PL and /sup 125/I- or beta-lactamase-labeled anti-LAV were used as reagents for radioimmunoassay (RIA) - or enzyme-linked immunoassay (ELISA) - inhibition tests to detect antibodies directed predominantly against PL (anti-PL). Among 257 individuals belonging to groups at high risk of developing AIDS, 117 (45.5%) were positive for anti-PL and 108 (42%) for anti-P24, respectively. The 2 individuals among 600 random blood donors found to be anti-P24-positive in the preceding study also had anti-PL in their serum. Sera from 500 additional blood donors were screened for anti-PL and 1 of these was positive. The implication of these findings for screening of blood donors is discussed. 17 refs.; 2 figs.; 1 table.

  1. Enzyme immunoassay for measurement of murine plasminogen activator inhibitor-1, employing a specific antibody produced by the DNA vaccine method.

    Science.gov (United States)

    Yamada, Takayuki; Takagi, Akira; Takeshita, Kyosuke; Yamamoto, Koji; Ito, Masafumi; Matsushita, Tadashi; Murate, Takashi; Saito, Hidehiko; Kojima, Tetsuhito

    2003-01-01

    We developed a sensitive immunoassay to determine the concentration of mouse plasminogen activator inhibitor-1. The assay was a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) based on the production of a specific polyclonal antibody against mouse plasminogen activator inhibitor type-1 (PAI-1) used both as a trapping and detecting antibody. This antibody was raised in a rabbit by direct introduction of the expression vector plasmid DNA encoding mouse PAI-1, instead of conventional immunization with the purified protein. The standard curve was constructed with a recombinant glutathione S-transferase (GST)-mouse PAI-1 fusion protein (GST-mPAI-1) and dose-response of the assay was linear for GST-mPAI-1 between 6.25 and 100 pM. In order to assess the consistency of the assay, we measured PAI-1 antigen in normal mouse pooled plasma several times. We found that the intra-assay and inter-assay coefficients of variation (CV) were 4.8% and 9.2%, respectively, indicating that the ELISA would be sufficiently repeatable and reproducible. In this assay, lipopolysaccharide (LPS)-injected mice showed substantially higher levels (22-fold) of plasma PAI-1 antigen than did control mice (12.5+/-2.4 vs. 0.58+/-0.16 nM), similar to results reported elsewhere. Taken together, the DNA vaccine method is extremely useful for preparing specific antibodies against mouse PAI-1, which can be utilized to establish the ELISA and analyze the profile of PAI-1 distributions in mice under various conditions. This approach might also be useful for immunological investigation of other coagulation factors and related proteins.

  2. Enzyme immunoassay for DDT analysis in Lebanese soils

    International Nuclear Information System (INIS)

    Bashour, I.; Dagher, S.; Shammas, G.; Sukkariyah, B.; Kawar, N.

    2000-01-01

    Full text: The use of enzyme-linked immunosorbent assay (ELISA) technique in estimating pesticide residue in soils is a faster, less expensive and easier method to use than the gas chromatography (GC) analysis technique..In the test, DDT pesticide residues in the simple compete with enzyme (horseradish peroxidase)-labeled DDT for a limited number of antibody binding sites on the inside surfaces of the test wells; the envirologix plate kit was tested for the measurement of total DDT in virgin and fortified (0-1000 ng g exp-1) soil samples of different properties from Lebanon. Extraction of DDT from soil was done by shaking the samples for 16 hours on a mechanical shaker with 90% methanol without any clean-up steps. Then the samples were allowed to stand for 30 minutes and an aliquot was taken from the clear supernatant. The DDT in the extract was measured in triplicate by GC and ELISA. The results indicated that the two techniques were highly correlated (r2 =0.9671-0.9973). Differences in soils physical and chemical properties did not accuracy of the detection limits of ELISA when compared to GC-ECD results. Immunoassay technique is a suitable method for rapid and accurate measurement of DDT residue in mineral Lebanese soils

  3. A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.

    Science.gov (United States)

    Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying

    2014-08-15

    Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. The right environment for the immunoassay

    International Nuclear Information System (INIS)

    Emon, J.M. Van; Gerlach, C.L.

    1995-01-01

    For the US Environmental Protection Agency (EPA), the first in-house research effort began in 1987, when results of an early immunoassay field study verified the technology's potential for environmental applications. Looking at the fundamental features of immunochemical reactions from the clinical laboratories, analytical chemists realized the potential value of these methods for hazardous waste site characterization and pesticide monitoring. Immunoassays rely on the interaction between an antibody and a target analyte. For environmental purposes, enzyme immunoassays are generally used. After the target analyte binds to the antibody, an enzymatic reaction yields a colorimetric change. This change, read visually or by a spectrophotometer, indicates the concentration of the target analyte. Promising results with assays for compounds (such as paraquat and pentachlorophenol) and compound groups (such as total petroleum hydrocarbons and polychlorinated biphenyls) spurred interest among various entrepreneurs. The first target market for immunoassays was environmental engineers and field crews who needed quick answers on-site to determine the direction of further remediation efforts

  5. Preparation by irradiation of a solid support for enzyme immunoassay

    International Nuclear Information System (INIS)

    Kumakura, M.; Kaetsu, I.

    1984-01-01

    Reagents (immobilized anti-α-fetoprotein discs) having a porous structure were prepared for enzyme immunoassay of α-fetoprotein by radiation polymerization at low temperatures. Discs were attached to sticks for easy handling. The activity (determined by absorbance at 492 nm) of the discs varied with the hydrophilic properties and size of the discs. The discs are sufficiently sensitive and precise for enzyme immunoassay of α-fetoprotein. Anti-AFP dissolved in PBS solution was mixed with a monomer solution of hydroxyethyl methacrylate and hydroxypropyl methacrylate. The mixture was frozen to -78 0 C and gamma irradiated. (Auth.)

  6. Evidence for carcinoembryonic antigen using radioimmunoassay and enzyme immunoassay

    International Nuclear Information System (INIS)

    Kungda Gao, L.

    1980-01-01

    A commercially available radioimmunoassay for the determination of carcinoembryonic antigen (CEA) was initially compared with an enzyme immunoassay (EIA). Considerable differences were found between the individual value. For three patients suffering from carcinomas of the digestive tract a better indication of the disease was given in the RIA than in the EIA. A further 110 patients with various illnesses were examined for serum CEA-levels using RIA. A method for measuring CEA in feces by RIA was developed. The normal range lies below 300 ng/ml. This assay could be of significance for the early recognition of colo-rectal carcinoma. In part II of this dissertation CEA was isolated from colo-rectal carcinomas using three different gel filtration media. It was only possible to obtain almost pure CEA (24 μg CEA per μg protein) by one of the methods. Six guinea pigs were immunized with the isolated CEA and all developed antibodies. The isolated CEA was labelled with 125 I and an own RIA saturation sequence and double antibody separation was developed. One of the antisera was able to distinguish without overlap 7 healthy patients from 7 suffering from colo-rectal carcinomas in non-extracted serum. (orig./MG) [de

  7. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  8. A study using an isotope probe comparing immunoassay with serology in detection of Brucella Abortus antibody

    International Nuclear Information System (INIS)

    Devlin, J.G.; Redington, F.; Stephenson, M.

    1986-01-01

    We report a comparison of radio-immunoassay with conventional serology in the detection of brucella abortus antibody from three laboratories. Overall agreement by Chi squared analysis is 5%. There are significant differences between laboratories and a significant number of sero negative suspect sera (from 20% - 60%) were positive by ratio-immunoassay test. We suspect that conventional serology under-reports the incidence of antibody to brucella abortus. (author)

  9. Fieldable, real-time enzyme immunoassay kits for drugs on surfaces

    Science.gov (United States)

    Chiappini, Michele W.; Wendel, Gregory J.; Duquette, Peter H.; Hamilton, Martha J.; Chudzik, Stephen J.; Chappa, Ralph A.

    1994-03-01

    Immunoassays (e.g., RIA, EIA) have been demonstrated to be useful for rapid, convenient detection and semiquantitative analysis of drugs. Thermedics Detection, Inc. manufactures a rapid, sensitive, self-contained, disposable, EIA device, developed by Bio-Metric Systems, Inc., designed to allow untrained personnel to perform in field situations. This format has been developed for drugs in biological fluids and on surfaces. The analyte in the test sample competes with an enzyme-analyte conjugate for a limited number of immobilized antibody sites. The AccuPRESS Test format can detect analytes at 10 ppb in biological fluids, water, and soil, and on surfaces, such as suitcases, vehicles, tables and hands, with positive results indicated by clearly visible color development within 5 minutes. This format is designed to have all dry components and to have an ambient shelf life of greater than one year. The format is available for cocaine and opiate derivatives, including heroin, and is readily adaptable for use with numerous other drugs, explosives, and environmental pollutants.

  10. Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.

    Science.gov (United States)

    Xie, Zhen-ming; Yu, Lin; Fang, Li-sha

    2015-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.

  11. Targeted deposition of antibodies on a multiplex CMOS microarray and optimization of a sensitive immunoassay using electrochemical detection.

    Directory of Open Access Journals (Sweden)

    John Cooper

    2010-03-01

    Full Text Available The CombiMatrix ElectraSense microarray is a highly multiplex, complementary metal oxide semiconductor with 12,544 electrodes that are individually addressable. This platform is commercially available as a custom DNA microarray; and, in this configuration, it has also been used to tether antibodies (Abs specifically on electrodes using complementary DNA sequences conjugated to the Abs.An empirical method is described for developing and optimizing immunoassays on the CombiMatrix ElectraSense microarray based upon targeted deposition of polypyrrole (Ppy and capture Ab. This process was automated using instrumentation that can selectively apply a potential or current to individual electrodes and also measure current generated at the electrodes by an enzyme-enhanced electrochemical (ECD reaction. By designating groups of electrodes on the array for different Ppy deposition conditions, we determined that the sensitivity and specificity of a sandwich immunoassay for staphylococcal enterotoxin B (SEB is influenced by the application of different voltages or currents and the application time. The sandwich immunoassay used a capture Ab adsorbed to the Ppy and a reporter Ab labeled for fluorescence detection or ECD, and results from these methods of detection were different.Using Ppy deposition conditions for optimum results, the lower limit of detection for SEB using the ECD assay was between 0.003 and 0.01 pg/ml, which represents an order of magnitude improvement over a conventional enzyme-linked immunosorbant assay. In the absence of understanding the variables and complexities that affect assay performance, this highly multiplexed electrode array provided a rapid, high throughput, and empirical approach for developing a sensitive immunoassay.

  12. Evaluation of a magnetic particles-based chemiluminescence enzyme immunoassay for Golgi protein 73 in human serum.

    Science.gov (United States)

    Liu, Xiangyi; Wan, Xiaohua; Lu, Sheng; Zhang, Lijun; Yu, Shaohua; Lu, Xinxin

    2015-05-20

    Golgi protein 73 (GP73) is regarded as a potential serum biomarker for early diagnosis of hepatocellular carcinoma (HCC). We developed a rapid magnetic particles-based chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of serum GP73. Fluorescein isothiocyanate (FITC) and alkaline phosphatase (ALP) were used to label 2 different monoclonal antibodies to GP73. Serum GP73 was captured with labeled antibodies and formed a sandwiched immunoreaction. The magnetic particles (MPs) coated with anti-FITC antibody were used as a means of separation of the GP73 protein from other serum proteins. After adding the enzyme substrate solution, the relative light unit (RLU) was measured. A MPs-CLEIA for serum GP73 was established and evaluated. The RLU was directly proportional to the concentration of GP73. The method linearity was 5-600 μg/l. Limit of the blank was 2.19 μg/l. The intra- and inter-assay imprecision was 73-0.89), and the sensitivity and specificity, with cut-off value of 115.6 μg/l, were 75.4% and 92.1%, respectively. The proposed method demonstrates an acceptable performance for quantifying serum GP73. This assay could be appropriate for routine use in clinical laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Nitrocellulose membrane-based enzyme-linked immunoassay for dengue serotype-1 IgM detection

    International Nuclear Information System (INIS)

    Leon, S.; Guevara, C.; Chunga, A.

    1999-01-01

    To evaluate the sensitivity and specifity of a nitrocellulose membrane-based immunoassay for dengue IgM, with respect to capture enzyme immunoassay, for the diagnosis of dengue virus infection. 101 serum samples were processed and divided into 2 groups: 53 from dengue serotype 1 (DEN1) infected patients, and 48 from healthy subjects. Both groups were tested with a nitrocellulose membrane-based IgM capture enzyme immunoassay (NMB-EIA) and also with an ELISA as referential pattern. NMB-EIA testing detected IgM anti-DEN1 in 94,34% of samples from infected patients, and in 14,58% of control samples, whereas ELISA fails to report false positive or false negative results: NMB-EIA appears to be a good alternative for dengue infection diagnosis. (authors)

  14. A competitive enzyme immunoassay for the quantitative detection of cocaine from banknotes and latent fingermarks.

    Science.gov (United States)

    van der Heide, Susan; Garcia Calavia, Paula; Hardwick, Sheila; Hudson, Simon; Wolff, Kim; Russell, David A

    2015-05-01

    A sensitive and versatile competitive enzyme immunoassay (cEIA) has been developed for the quantitative detection of cocaine in complex forensic samples. Polyclonal anti-cocaine antibody was purified from serum and deposited onto microtiter plates. The concentration of the cocaine antibody adsorbed onto the plates, and the dilution of the cocaine-HRP hapten were both studied to achieve an optimised immunoassay. The method was successfully used to quantify cocaine in extracts taken from both paper currency and latent fingermarks. The limit of detection (LOD) of 0.162ngmL(-1) achieved with the assay compares favourably to that of conventional chromatography-mass spectroscopy techniques, with an appropriate sensitivity for the quantification of cocaine at the low concentrations present in some forensic samples. The cEIA was directly compared to LC-MS for the analysis of ten UK banknote samples. The results obtained from both techniques were statistically similar, suggesting that the immunoassay was unaffected by cross-reactivity with potentially interfering compounds. The cEIA was used also for the detection of cocaine in extracts from latent fingermarks. The results obtained were compared to the cocaine concentrations detected in oral fluid sampled from the same individual. Using the cEIA, we have shown, for the first time, that endogeneously excreted cocaine can be detected and quantified from a single latent fingermark. Additionally, it has been shown that the presence of cocaine, at similar concentrations, in more than one latent fingermark from the same individual can be linked with those concentrations found in oral fluid. These results show that detection of drugs in latent fingermarks could directly indicate whether an individual has consumed the drug. The specificity and feasibility of measuring low concentrations of cocaine in complex forensic samples demonstrate the effectiveness and robustness of the assay. The immunoassay presents a simple and cost

  15. Myeloma-Derived Light Chain Paired with a Diagnostic Monoclonal Antibody Hinders Immunoassay Performance.

    Science.gov (United States)

    Tu, Bailin; Tieman, Bryan; Moore, Jeffrey; Pan, You; Muerhoff, A Scott

    2017-06-01

    Monoclonal antibodies are widely used as the capture and detection reagents in diagnostic immunoassays. In the past, myeloma fusion partners expressing endogenous heavy and/or light chains were often used to generate hybridoma cell lines. As a result, mixed populations of antibodies were produced that can cause inaccurate test results, poor antibody stability, and significant lot-to-lot variability. We describe one such scenario where the P3U1 (P3X63Ag8U.1) myeloma fusion partner was used in the generation of a hybridoma producing protein induced vitamin K absence/antagonist-II (PIVKA II) antibody. The hybridoma produces three subpopulations of immunoglobulin as determined by ion exchange (IEx) chromatography that exhibit varying degrees of immunoreactivity (0%, 50%, or 100%) to the target antigen as determined by Surface Plasmon Resonance. To produce an antibody with the highest possible sensitivity and specificity, the antigen-specific heavy and light chain variable domains (VH and VL) were cloned from the hybridoma and tethered to murine IgG1 and kappa scaffolds. The resulting recombinant antibody was expressed in Chinese hamster ovary cells and is compatible for use in a diagnostic immunoassay.

  16. Double Antibody EIA of Cortisol Using Peroxidase As Label

    International Nuclear Information System (INIS)

    Karim, F.M.; Hamad, A.W.R.; Hashim, A.M.

    1998-01-01

    An enzyme immunoassay (EIA) technique for plasma cortisol was established by using cortisol-3 (carboxymethyl) oxime covalently linked to the horseradish peroxidase as the label. An antibody raised in the rabbits against cortisol-3-(carboxy-methyl) oxime-bovline serum albumin was used as the first anti-body. Sheep anti-rabbit gamma-globulin serum with 8 percent poly-ethyleneglycol were used to separate antibody-bound and free cortisol. The enzyme activity of the bound fraction was measured with ortho-phenylene diamine as substrate. The procedure performed at room temperature was evaluated by sensitivity (50 pg/ tube). The correlation coefficient between our enzyme immunoassay technique and radioimmunoassay technique for determination of plasma cortisol was 97 percent

  17. The management of isolated positive syphilis enzyme immunoassay results in HIV-negative patients attending a sexual health clinic.

    Science.gov (United States)

    Thorley, Nicola; Adebayo, Michael; Smit, Erasmus; Radcliffe, Keith

    2016-08-01

    An unconfirmed positive treponemal enzyme immunoassay (enzyme immunoassay positive, Treponema pallidum particle agglutination negative and rapid plasma reagin negative) presents a clinical challenge to distinguish early syphilis infection from false-positive results. These cases are referred for syphilis line assay (INNO-LIA) and recalled for repeat syphilis serology. We performed a retrospective audit to establish the proportion of HIV-negative cases with unconfirmed positive enzyme immunoassay results, the proportion of these cases that received an INNO-LIA test and repeat syphilis serology testing and reviewed the clinical outcomes; 0.35% (80/22687) cases had an unconfirmed positive treponemal enzyme immunoassay result. Repeat syphilis serology was performed in 80% (64/80) cases, but no additional cases of syphilis were identified. Eighty-eight per cent (70/80) received an INNO-LIA test; 14% (5/37) unconfirmed enzyme immunoassay-positive cases with no prior history of syphilis were confirmed on INNO-LIA assay, supporting a diagnosis of latent syphilis. As a confirmatory treponemal test, the INNO-LIA assay may be more useful than repeat syphilis serological testing. © The Author(s) 2016.

  18. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.

    Science.gov (United States)

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-12-01

    To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.

  19. Enzyme-linked immunosorbent assay for the quantitative/qualitative analysis of plant secondary metabolites.

    Science.gov (United States)

    Sakamoto, Seiichi; Putalun, Waraporn; Vimolmangkang, Sornkanok; Phoolcharoen, Waranyoo; Shoyama, Yukihiro; Tanaka, Hiroyuki; Morimoto, Satoshi

    2018-01-01

    Immunoassays are antibody-based analytical methods for quantitative/qualitative analysis. Since the principle of immunoassays is based on specific antigen-antibody reaction, the assays have been utilized worldwide for diagnosis, pharmacokinetic studies by drug monitoring, and the quality control of commercially available products. Berson and Yalow were the first to develop an immunoassay, known as radioimmunoassay (RIA), for detecting endogenous plasma insulin [1], a development for which Yalow was awarded the Nobel Prize in Physiology or Medicine in 1977. Even today, after half a century, immunoassays are widely utilized with some modifications from the originally proposed system, e.g., radioisotopes have been replaced with enzymes because of safety concerns regarding the use of radioactivity, which is referred to as enzyme immunoassay/enzyme-linked immunosorbent assay (ELISA). In addition, progress has been made in ELISA with the recent advances in recombinant DNA technology, leading to increase in the range of antibodies, probes, and even systems. This review article describes ELISA and its applications for the detection of plant secondary metabolites.

  20. Application of a Newly Developed High-Sensitivity HBsAg Chemiluminescent Enzyme Immunoassay for Hepatitis B Patients with HBsAg Seroclearance

    OpenAIRE

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-01-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstr...

  1. Production of monoclonal antibodies for sandwich immunoassay detection of Pacific ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2010-10-01

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of Pacific ciguatoxins CTX3C and 51-hydroxyCTX3C were prepared by immunization of mice with the protein conjugates of rationally designed synthetic haptens in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C or 51-hydroxyCTX3C. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C and 51-hydroxyCTX3C at the ppb level with no cross-reactivity against the other marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin. Copyright 2009 Elsevier Ltd. All rights reserved.

  2. Competitive photometric enzyme immunoassay for fullerene C60 and its derivatives using a fullerene conjugated to horseradish peroxidase

    International Nuclear Information System (INIS)

    Hendrickson, Olga D.; Smirnova, Natalya I.; Zherdev, Anatoly V.; Dzantiev, Boris B.; Sveshnikov, Peter G.

    2016-01-01

    The article describes a highly sensitive single-step microplate enzyme immunoassay of the ELISA type for fullerene C 60 and its derivatives. Monoclonal anti-fullerene antibodies and a conjugate between fullerene and horseradish peroxidase were used as specific reagents. A direct competitive ELISA was carried out that was based on antibodies immobilized in the well of a microtiter plate, a peroxidase-labeled antigen, and detection via the dye formed from 3,3′,5,5′-tetramethylbenzidine and hydrogen peroxide. Both pristine fullerene C 60 and its water-soluble forms can be determined. The detection limits are 1.5 ng∙mL −1 for fullerene C 60 , and between 0.1 and 1.3 ng∙mL −1 for its derivatives. This ELISA format allows for almost two-fold reduction of the time needed for the assay in comparison to indirect scheme with labeled antibodies. (author)

  3. Determination of digoxin by enzyme immunoassay and radioimmunoassay

    International Nuclear Information System (INIS)

    Mueller, H.; Braeuer, H.; Foerster, G.; Reinhardt, M.

    1978-01-01

    The results of parallel determinations of digoxin in the sera of non selected patients (n=104) by enzyme immunoassay (EMIT.EIA) and radioimmunoassay (J-125 labeled RIA) were compared with each other. The determinations revealed considerably different concentrations; the values determined by EIA were statistical lower (for EIA 1,09+'0,99ng/ml, for RIA 1,34+'1,01ng/ml, p [de

  4. Biotin IgM Antibodies in Human Blood: A Previously Unknown Factor Eliciting False Results in Biotinylation-Based Immunoassays

    Science.gov (United States)

    Chen, Tingting; Hedman, Lea; Mattila, Petri S.; Jartti, Laura; Jartti, Tuomas; Ruuskanen, Olli; Söderlund-Venermo, Maria; Hedman, Klaus

    2012-01-01

    Biotin is an essential vitamin that binds streptavidin or avidin with high affinity and specificity. As biotin is a small molecule that can be linked to proteins without affecting their biological activity, biotinylation is applied widely in biochemical assays. In our laboratory, IgM enzyme immuno assays (EIAs) of µ-capture format have been set up against many viruses, using as antigen biotinylated virus like particles (VLPs) detected by horseradish peroxidase-conjugated streptavidin. We recently encountered one serum sample reacting with the biotinylated VLP but not with the unbiotinylated one, suggesting in human sera the occurrence of biotin-reactive antibodies. In the present study, we search the general population (612 serum samples from adults and 678 from children) for IgM antibodies reactive with biotin and develop an indirect EIA for quantification of their levels and assessment of their seroprevalence. These IgM antibodies were present in 3% adults regardless of age, but were rarely found in children. The adverse effects of the biotin IgM on biotinylation-based immunoassays were assessed, including four inhouse and one commercial virus IgM EIAs, showing that biotin IgM do cause false positivities. The biotin can not bind IgM and streptavidin or avidin simultaneously, suggesting that these biotin-interactive compounds compete for the common binding site. In competitive inhibition assays, the affinities of biotin IgM antibodies ranged from 2.1×10−3 to 1.7×10−4 mol/L. This is the first report on biotin antibodies found in humans, providing new information on biotinylation-based immunoassays as well as new insights into the biomedical effects of vitamins. PMID:22879954

  5. Evaluation of envelope glycoprotein E(rns) of an atypical bovine pestivirus as antigen in a microsphere immunoassay for the detection of antibodies against bovine viral diarrhea virus 1 and atypical bovine pestivirus.

    Science.gov (United States)

    Vijayaraghavan, Balaje; Xia, Hongyan; Harimoorthy, Rajiv; Liu, Lihong; Belák, Sándor

    2012-11-01

    Atypical bovine pestiviruses are related antigenically and phylogenetically to bovine viral diarrhea viruses (BVDV-1 and BVDV-2), and may cause the same clinical manifestations in animals. Glycoprotein E(rns) of an atypical bovine pestivirus Th/04_KhonKaen was produced in a baculovirus expression system and was purified by affinity chromatography. The recombinant E(rns) protein was used as an antigen in a microsphere immunoassay for the detection of antibodies against BVDV-1 and atypical bovine pestivirus. The diagnostic performance of the new method was evaluated by testing a total of 596 serum samples, and the assay was compared with enzyme-linked immunosorbent assay (ELISA). Based on the negative/positive cut-off median fluorescence intensity (MFI) value of 2800, the microsphere immunoassay had a sensitivity of 100% and specificity of 100% compared to ELISA. The immunoassay was able to detect antibodies against both BVDV-1 and the atypical pestivirus. This novel microsphere immunoassay has the potential to be multiplexed for simultaneous detection of antibodies against different bovine pathogens in a high-throughput and economical way. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. The influence of intravenous canrenoate on the determination of digoxin in serum by radio- and enzyme-immunoassay

    International Nuclear Information System (INIS)

    Rietbrock, N.; Lichey, J.; Borner, K.; Freie Univ. Berlin

    1979-01-01

    Ten patients were kept on a constant maintenance dose of digoxin. During a baseline period of 6 days, blood samples were taken daily for analysis of digoxin in serum. On the 6th day the maintenance dose of digoxin was withheld and a single intravenous dose of 200mg potassium-canrenoate (AldactoneR) was administered to all patients. Digoxin in serum was determined by a classical radioimmunoassay with 125 I-digoxin and solid phase technique (RIA-NEN) and partly by a heterogenous enzyme-immunoassay (EnzymunR-Digoxin, Boehringer, Mannheim). Results of the radioimmunoassay indicated a rise of apparent serum digoxin levels with an average maximum of 201% of the mean baseline value 30 min after injection of canrenoate and a gradual return to the baseline value within 6 to 10 hours. Contrary to the radioimmunoassay there was no interference when using the enzyme-immunoassay in a subgroup of identical serum samples: serum digoxin levels remained constant throughout the test. Interference of determinations of digoxin in serum by spironolactone and its metabolites appear to be related to two factors: 1. The mode of administration and the amount of interfering drug, 2. the specifity of the digoxin antibody used in the kit. (orig.) [de

  7. Plasmon enhanced fluoro-immunoassay using egg yolk antibodies for ultra-sensitive detection of herbicide diuron.

    Science.gov (United States)

    Sharma, Priyanka; Kukkar, Manil; Ganguli, Ashok K; Bhasin, Aman; Suri, C Raman

    2013-08-07

    Plasmon enhanced fluorescence immunoassay (PEFI) format has been reported in developing a sensitive heterogeneous fluoroimmunoassay for monitoring the phenylurea herbicide diuron. Computer-assisted molecular modeling was carried out to study the conformational and electrostatic effects of synthesized hapten for producing highly specific egg yolk antibody against a phenyl urea herbicide diuron. The generated antibodies were labeled with fluorescein isothiocyanate at different molar ratios and used as tracer in the developed fluorescence based immunoassay. The sensitivity of the assay format was enhanced by using silver nanoparticles tagged with bovine serum albumin as a new blocking reagent in the developed PEFI format. Enhancer treatment on the developed immunoassay showed a significant improvement of fluorescence signal intensity with approximately 10 fold increase in assay sensitivity. The immunoassay has a detection limit of 0.01 ng mL(-1) with good signal precision (~2%) in the optimum working concentration range between 1 pg mL(-1) to 10 μg mL(-1) of diuron. These findings facilitate high throughput fluorescence-based processes that could be useful in biology, drug discovery and compound screening applications.

  8. A sensitive progesterone enzyme immunoassay for cow, goat and llama plasma using a monoclonal antibody and Danazol (17-α-2,4-pregnadien-20-yno (2,3-D) isoxazol-17-ol) as a displacing agent

    International Nuclear Information System (INIS)

    Aba, M.A.; Carlsson, M.A.; Karlsson, A.; Forsberg, M.

    2001-01-01

    A sensitive progesterone enzyme immunoassay was developed for cow, goat and llama plasma using a monoclonal antibody and Danazol (17-α-2,4-pregnadien-20-yno (2,3-d) isoxazol-17-ol) as a displacing agent. The microtitration plates were first coated with progesterone 3 (o-carboxy-methyl) oxine: BSA conjugate. The immune reaction was performed by incubating overnight a mixture of 50 μL of plasma and 100 μL of first antibody. After washing, 100 μL of the second antibody (horse radish peroxidase conjugated anti-mouse IgG) were added. The plates were incubated for 1 hour and washed. Immediately the substrate solution was added and finally the reaction stopped and optical density measured. This assay allows accurate determination of progesterone in plasma from several species with good specificity, precision and accuracy, and is suitable for the rapid assessment of luteal function and reproductive status in both clinical and research situations. (author)

  9. Novel photoluminescence enzyme immunoassay based on supramolecular host-guest recognition using L-arginine/6-aza-2-thiothymine-stabilized gold nanocluster.

    Science.gov (United States)

    Wang, Youmei; Lu, Minghua; Tang, Dianping

    2018-06-30

    A new photoluminescence (PL) enzyme immunoassay was designed for sensitive detection of aflatoxin B 1 (AFB 1 ) via an innovative enzyme substrate, 6-aza-2-thiothymine-stabilized gold nanocluster (AAT-AuNC) with L-arginine. The enzyme substrate with strong PL intensity was formed through supramolecular host-guest assembly between guanidine group of L-arginine and AAT capped on the surface of AuNC. Upon arginase introduction, the captured L-arginine was hydrolyzed into ornithine and urea, thus resulting in the decreasing PL intensity. Based on this principle, a novel competitive-type immunoreaction was first carried out on AFB 1 -bovine serum albumin (AFB 1 -BSA) conjugate-coated microplate, using arginase-labeled anti-AFB 1 antibody as the competitor. Under the optimum conditions, the PL intensity increased with the increment of target AFB 1 , and allowed the detection of the analyte at concentrations as low as 3.2 pg mL -1 (ppt). Moreover, L-arginine-AAT-AuNC-based PL enzyme immunoassay afforded good reproducibility and acceptable specificity. In addition, the accuracy of this methodology, referring to commercial AFB 1 ELISA kit, was evaluated to analyze naturally contaminated or spiked peanut samples, giving well-matched results between two methods, thus representing a useful scheme for practical application in quantitative monitoring of mycotoxins in foodstuff. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Comparison of two enzyme-linked immunosorbent assays and one rapid immunoblot assay for detection of herpes simplex virus type 2-specific antibodies in serum

    NARCIS (Netherlands)

    Groen, J; Van Dijk, G; Niesters, H G; Van Der Meijden, W I; Osterhaus, A D

    The sensitivities and specificities of three immunoassays for the detection of herpes simplex virus type 2 (HSV-2)-specific immunoglobulin G antibodies in serum, including the one-strip rapid immunoblot assay (RIBA; Chiron Corporation) and two indirect enzyme immunosorbent assays (EIA; Gull

  11. Enzyme immunoassays for the diagnosis of bovine brucellosis. Trial in Latin America

    International Nuclear Information System (INIS)

    Gall, D.; Nielsen, K.; Colling, A.; Marino, O.; Moreno, E.; Perez, B.; Samartino, L.

    1998-01-01

    The results of a field trail conducted in Latin America with two indirect (IELISA) and two competitive (CELISA) enzyme immunoassays for the detection of bovine antibody to Brucella abortus are reported. One of the CELISA formats performed most accurately. The relative sensitivity of this assay was 97.47%, the relative specificity for unexposed cattle was 98.32% and the specificity in cattle vaccinated with B. abortus strain 19 was 96.51%. The same assay format under Canadian conditions had a sensitivity of 100%, a specificity of 99.90% and a specificity of 97.7% in a strain 19 vaccinated population. Overall, the CELISA performed as expected and the results were not dissimilar to the results obtained in the Canadian study thus providing further evidence that this CELISA can in many instances differentiate infected cattle from those that are vaccinated or infected with a cross-reacting organism while still giving very low false positive or false negative results. (author)

  12. Sandwich-type enzyme immunoassay for big endothelin-I in plasma: concentrations in healthy human subjects unaffected by sex or posture.

    Science.gov (United States)

    Aubin, P; Le Brun, G; Moldovan, F; Villette, J M; Créminon, C; Dumas, J; Homyrda, L; Soliman, H; Azizi, M; Fiet, J

    1997-01-01

    A sandwich-type enzyme immunoassay has been developed for measuring human big endothelin-1 (big ET-1) in human plasma and supernatant fluids from human cell cultures. Big ET-1 is the precursor of endothelin 1 (ET-1), the most potent vasoconstrictor known. A rabbit antibody raised against the big ET-1 COOH-terminus fragment was used as an immobilized antibody (anti-P16). The Fab' fragment of a monoclonal antibody (1B3) raised against the ET-1 loop fragment was used as the enzyme-labeled antibody, after being coupled to acetylcholinesterase. The lowest detectable value in the assay was 1.2 pg/mL (0.12 pg/well). The assay was highly specific for big ET-1, demonstrating no cross-reactivity with ET-1, big endothelin-2 (big ET-2), and big endothelin-3 (big ET-3). We used this assay to evaluate the effect of two different postural positions (supine and standing) on plasma big ET-1 concentrations in 11 male and 11 female healthy subjects. Data analysis revealed that neither sex nor body position influenced plasma big ET-1 concentrations. This assay should thus permit the detection of possible variations in plasma concentrations of big ET-1 in certain pathologies and, in association with ET-1 assay, make possible in vitro study of endothelin-converting enzyme activity in cell models. Such studies could clarify the physiological and clinical roles of this family of peptides.

  13. Erythema migrans and serodiagnosis by enzyme immunoassay and immunoblot with three borrelia species.

    Science.gov (United States)

    Stanek, G; Breier, F; Menzinger, G; Schaar, B; Hafner, M; Partsch, H

    1999-12-10

    There is wide divergence of opinion between physicians regarding the use of serological measures for the diagnosis and treatment of erythema migrans, the hallmark of Lyme borreliosis. We studied the outcome of an enzyme immunoassay and immunoblot (Western blot) used on the sera of patients who had suffered tick bite and erythema migrans, and had been subsequently treated with various antibiotics. Ninety-nine consecutive patients presenting with erythema migrans after tick bite were prospectively recruited at the outpatient department of two Vienna City hospitals and at the consultation office for Lyme borreliosis of the Institute of Hygiene. University Vienna. Blood samples were taken before antibiotic treatment and 3 and 6 months thereafter. Blood samples from 100 blood donors served as controls. Antibodies against Borrelia burgdorferi sensu lato were determined by enzyme immunoassay (IgG and IgM EIA) and by IgG immunoblot. The latter was performed with isolates of B. alzelii (H2) B. burgdorferi sensu stricto (Le) and B. garinii (W) from Austrian patients. The 4 interpretation criteria for immunoblot results were: A (3 bands out of 8), B (2 bands out of 9), C and D (1 band out of 6). In all patients, the erythema resolved within the treatment period. No complications secondary to the borrelia infection were registered. After treatment there was no significant change in titre, nor was there a difference in the immunoblot pattern between the first, second and third serum samples. Serum antibodies to B. burgdorferi were positive by EIA in 22.9% (IgG) and 2.5% (IgM). Immunoblot results offered by borrelia species and by the interpretation criteria, ranging between 8.3% (criterion A, strain Le) and 44.2% (criterion D, strain H2). By EIA, control samples were IgG and IgM positive in 5% and 1%, respectively. Positive immunoblot results with strain H2 were found in 9%, 13%, 18%, and 20% by the criteria A through D respectively. After antibiotic treatment of erythema

  14. Oriented antibody immobilization to polystyrene macrocarriers for immunoassay modified with hydrazide derivatives of poly(methacrylic acid

    Directory of Open Access Journals (Sweden)

    Vinokurova Ludmila G

    2001-08-01

    Full Text Available Abstract Background Hydrophobic polystyrene is the most common material for solid phase immunoassay. Proteins are immobilized on polystyrene by passive adsorption, which often causes considerable denaturation. Biological macromolecules were found to better retain their functional activity when immobilized on hydrophilic materials. Polyacrylamide is a common material for solid-phase carriers of biological macromolecules, including immunoreagents used in affinity chromatography. New macroformats for immunoassay modified with activated polyacrylamide derivatives seem to be promising. Results New polymeric matrices for immunoassay in the form of 0.63-cm balls which contain hydrazide functional groups on hydrophilic polymer spacer arms at their surface shell are synthesized by modification of aldehyde-containing polystyrene balls with hydrazide derivatives of poly(methacrylic acid. The beads contain up to 0.31 μmol/cm2 active hydrazide groups accessible for covalent reaction with periodate-oxidized antibodies. The matrices obtained allow carrying out the oriented antibody immobilization, which increases the functional activity of immunosorbents. Conclusions An efficient site-directed antibody immobilization on a macrosupport is realized. The polymer hydrophilic spacer arms are the most convenient and effective tools for oriented antibody coupling with molded materials. The suggested scheme can be used for the modification of any other solid supports containing electrophilic groups reacting with hydrazides.

  15. Clinical significance of quantitative analysis of thyroid peroxidase antibody (TPOAb) with chemiluminescence enzyme immunoassay

    International Nuclear Information System (INIS)

    Zhu Cuiying; Wang Qing; Huang Gang

    2004-01-01

    Objective: The only method of laboratory diagnosis for autoimmune thyroid diseases used to be serum TGA and TMA detections. Morerecently, quantitative analysis of TPOAb has been introduced. To assess the relative sensitivity of these tests , positive rates detected with the respective tests were compared. Methods: Serum TGA, TMA (with RIA) and TPOAb (with chemiluminescence enzyme immunoassay) were simultaneously detected in 998 cases of thyroid diseases (hyperthyroidism 307, Hashimoto's disease 193, simple goiter 498). For complementary sake, fine needle aspiration cytology was obtained in a number of cases including all the patients with Hashimoto's disease. Results: Positive detection rate of TPOAb in three groups of patients (hyperthyroidism, Hashimoto's, simple goiter) was 81.76%, 96.89 % and 42.97% respectively. With TMA, the positive rate was only 54.72%, 65.80%, 22.09% respectively. About one third more cases would be detected with the newer method. Conclusion: For the laboratory detection of auto immune thyroid diseases, quantitative analysis of TPOAb is much wore sensitive than the conventional TMA detection. (authors)

  16. Enzymatic amplification of a flow-injected thermometric enzyme-linked immunoassay for human insulin.

    Science.gov (United States)

    Mecklenburg, M; Lindbladh, C; Li, H; Mosbach, K; Danielsson, B

    1993-08-01

    A flow-injected thermometric enzyme linked immunoassay for human insulin which employs the lactate dehydrogenase/lactate oxidase (LDH/LOD) substrate recycling system for signal amplification is described. The system is composed of two columns, an immunosorbent column containing immobilized anti-insulin antibodies for sensing and a recycling column containing immobilized LDH/LOD/Catalase for detection. The effect of flow rates, conjugate concentrations, and chromatographic support material upon the sensitivity of the assay are investigated. The assay has a detection limit of 0.025 microgram/ml and a linear range from 0.05 to 2 micrograms/ml. This corresponds to a 10-fold increase in sensitivity over the unamplified system. A recombinant human insulin-proinsulin conjugate was also tested. The results show that enzymatic amplification can be employed to increase the sensitivity and reproducibility of flow injection assay-based biosensors. The implications of these results upon on-line analysis are discussed.

  17. Sensitivity-Enhancement of FRET Immunoassays by Multiple-Antibody Conjugation on Quantum Dots.

    Science.gov (United States)

    Annio, Giacomo; Jennings, Travis; Tagit, Oya; Hildebrandt, Niko

    2018-05-23

    Quantum dots (QDs) are not only advantageous for color-tuning, improved brightness, and high stability, but their nanoparticle surfaces also allow for the attachment of many biomolecules. Because IgG antibodies (ABs) are in the same size range of biocompatible QDs and the AB orientation after conjugation to the QD is often random, it is difficult to predict if few or many ABs per QD will lead to an efficient AB-QD conjugate. This is particularly true for homogeneous Förster resonance energy transfer (FRET) sandwich immunoassays, for which the ABs on the QD must bind a biomarker that needs to bind a second AB-FRET-conjugate. Here, we investigate the performance of Tb-to-QD FRET immunoassays against total prostate specific antigen (TPSA) by changing the number of ABs per QD while leaving all the other assay components unchanged. We first characterize the AB-QD conjugation by various spectroscopic, microscopic, and chromatographic techniques and then quantify the TPSA immunoassay performance regarding sensitivity, limit of detection, and dynamic range. Our results show that an increasing conjugation ratio leads to significantly enhanced FRET immunoassays. These findings will be highly important for developing QD-based immunoassays in which the concentrations of both ABs and QDs can significantly influence the assay performance.

  18. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    Science.gov (United States)

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of the antigen assay was confirmed by using guinea pig immunoglobulins from preimmunization sera. The sensitivity of the antigen assay was found to be at least 10 ng of antigen protein per ml. The suitability of the method for detecting antigens of T. gondii in different specimens was studied by experimental toxoplasma infection in mice. Antigenic components of T. gondii could be detected in different tissue specimens from infected animals from the first day after infection onwards. Toxoplasma antigen in serum and urine samples from infected mice reached detectable levels on day 2 after infection followed by a linear increase in antigen concentration in succeeding samples. This method might offer a valuable aid for a rapid etiological diagnosis also in human cases of acute toxoplasmosis. PMID:6345574

  19. Comparative digoxin determination in serum by means of a radioimmuno- and an enzyme immunoassay

    International Nuclear Information System (INIS)

    Reinhard, M.

    1981-01-01

    Two immunologic measuring methods for the quantitative digoxin determination in serum were compared. One method bases on the principle of radioisotope dilution, the second one on the principle of enzyme inhibition. The radioimmunoassay served as reference method. The limit of detection for RIA is 0.23 ng/ml, for EIA 0.40 ng/ml. For both methods the measuring range extends up to approx. 5.5 ng/ml. The degree of precision in series is 8.2% for RIA, 10.8% for EIA. Day-to-day precision is 4.4% for RIA, 15.2% for EIA. On comparison, the 59 serum samples of patients who received digoxin did not show any systematic difference. The results obtained can be transformed by means of the equations Csub(EIA) = 0.041 ng/ml + 0.936 Csub(RIA). In pathologic sera, however, there are significant differences disfavoring EIA, because due to high color concentrations or turbidities these sera do not permit any or any exact extinction measurements. The enzyme immunoassay should not be used with such sera. With regard to practicability the EIA corresponds more or less to RIA. The EIA can essentially be economized by using semi-microcuvettes and applying only the half of the recommended enzyme and antibody volume. (orig.) [de

  20. Development of an Indirect Competitive Enzyme-Linked Immunosorbent Assay for Glycocholic Acid Based on Chicken Single-Chain Variable Fragment Antibodies.

    Science.gov (United States)

    Cui, Xiping; Vasylieva, Natalia; Wu, Panpan; Barnych, Bogdan; Yang, Jun; Shen, Ding; He, Qiyi; Gee, Shirley J; Zhao, Suqing; Hammock, Bruce D

    2017-10-17

    Glycocholic acid (GCA) is an important metabolite of bile acids, whose urine levels are expected to be a specific diagnostic biomarker for hepatocellular carcinoma (HCC). A high-throughput immunoassay for determination of GCA would be of significant advantage and useful for primary diagnosis, surveillance, and early detection of HCC. Single-chain variable fragment (scFv) antibodies have several desirable characteristics and are an attractive alternative to traditional antibodies for the immunoassay. Because chicken antibodies possess single heavy and light variable functional domains, they are an ideal framework for simplified generation of recombinant antibodies for GCA detection. However, chicken scFvs have rarely been used to detect GCA. In this study, a scFv library was generated from chickens immunized with a GCA hapten coupled to bovine serum albumin (BSA), and anti-GCA scFvs were isolated by a phage-displayed method. Compared to the homologous coating antigen, use of a heterologous coating antigen resulted in about an 85-fold improvement in sensitivity of the immunoassay. This assay, under optimized conditions, had a linear range of 0.02-0.18 μg/mL, with an IC 50 of 0.06 μg/mL. The assay showed negligible cross-reactivity with various related bile acids, except for taurocholic acid. The detection of GCA from spiked human urine samples ranged from 86.7% to 123.3%. These results, combined with the advantages of scFv antibodies, indicated that a chicken scFv-based enzyme-linked immunosorbent assay is a suitable method for high-throughput screening of GCA in human urine.

  1. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference

    Directory of Open Access Journals (Sweden)

    Elena García-González

    2016-04-01

    Full Text Available Objectives: Endogenous antibodies (EA may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Subjects and methods: Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Results: Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house ‘nonsense’ sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Conclusions: Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern. Keywords: Endogenous antibodies, Immunoassay, Interference, Pituitary hormones, Case report

  2. Development of immunoassays for detecting clothianidin residue in agricultural products.

    Science.gov (United States)

    Li, Ming; Sheng, Enze; Cong, Lujing; Wang, Minghua

    2013-04-17

    Two enzyme-linked immunosorbent assays (ELISAs) based on polyclonal antibodies (PcAbs) for clothianidin are described: colorimetric detection format (ELISA) and pattern of chemiluminescent assay (CLEIA). Clothianidin hapten was synthesized and conjugated to bovine serum albumin (BSA) and ovalbumin (OVA) to produce immunogen and coating antigen. Anticlothianidin PcAbs were obtained from immunized New Zealand white rabbits. Under optimal conditions, the half-maximal inhibition concentration (IC₅₀) and the limit of detection (LOD, IC₂₀) of clothianidin were 0.046 and 0.0028 mg/L for the ELISA and 0.015 and 0.0014 mg/L for the CLEIA, respectively. There were no obvious cross-reactivities of the antibodies with its analogues except for dinotefuran. Recoveries of 76.4-116.4% for the immunoassays were achieved from spiked samples. The results of immunoassays for the spiked and authentic samples were largely consistent with gas chromatography. Therefore, the proposed immunoassays would be convenient and satisfactory analytical methods for the monitoring of clothianidin in agricultural products.

  3. Microfluidic Platform for Enzyme-Linked and Magnetic Particle-Based Immunoassay

    Directory of Open Access Journals (Sweden)

    Dorota G. Pijanowska

    2013-06-01

    Full Text Available This article presents design and testing of a microfluidic platform for immunoassay. The method is based on sandwiched ELISA, whereby the primary antibody is immobilized on nitrocelluose and, subsequently, magnetic beads are used as a label to detect the analyte. The chip takes approximately 2 h and 15 min to complete the assay. A Hall Effect sensor using 0.35-μm BioMEMS TSMC technology (Taiwan Semiconductor Manufacturing Company Bio-Micro-Electro-Mechanical Systems was fabricated to sense the magnetic field from the beads. Furthermore, florescence detection and absorbance measurements from the chip demonstrate successful immunoassay on the chip. In addition, investigation also covers the Hall Effect simulations, mechanical modeling of the bead–protein complex, testing of the microfluidic platform with magnetic beads averaging 10 nm, and measurements with an inductor-based system.

  4. Covalent Binding of Antibodies to Cellulose Paper Discs and Their Applications in Naked-eye Colorimetric Immunoassays.

    Science.gov (United States)

    Peng, Yanfen; Gelder, Victor Van; Amaladoss, Anburaj; Patel, Kadamb Haribhai

    2016-10-21

    This report presents two methods for the covalent immobilization of capture antibodies on cellulose filter paper grade No. 1 (medium-flow filter paper) discs and grade No. 113 (fast-flow filter paper) discs. These cellulose paper discs were grafted with amine functional groups through a silane coupling technique before the antibodies were immobilized on them. Periodate oxidation and glutaraldehyde cross-linking methods were used to graft capture antibodies on the cellulose paper discs. In order to ensure the maximum binding capacity of the capture antibodies to their targets after immobilization, the effects of various concentrations of sodium periodate, glutaraldehyde, and capture antibodies on the surface of the paper discs were investigated. The antibodies that were coated on the amine-functionalized cellulose paper discs through a glutaraldehyde cross-linking agent showed enhanced binding activity to the target when compared to the periodate oxidation method. IgG (in mouse reference serum) was used as a reference target in this study to test the application of covalently immobilized antibodies through glutaraldehyde. A new paper-based, enzyme-linked immunosorbent assay (ELISA) was successfully developed and validated for the detection of IgG. This method does not require equipment, and it can detect 100 ng/ml of IgG. The fast-flow filter paper was more sensitive than the medium-flow filter paper. The incubation period of this assay was short and required small sample volumes. This naked-eye, colorimetric immunoassay can be extended to detect other targets that are identified with conventional ELISA.

  5. Alkaline phosphatase-fused repebody as a new format of immuno-reagent for an immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo-Deok; Lee, Joong-jae [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of); Kim, Yu Jung [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Hantschel, Oliver [School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Lee, Seung-Goo [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Kim, Hak-Sung, E-mail: hskim76@kaist.ac.kr [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of)

    2017-01-15

    Enzyme-linked immunoassays based on an antibody-antigen interaction are widely used in biological and medical sciences. However, the conjugation of an enzyme to antibodies needs an additional chemical process, usually resulting in randomly cross-linked molecules and a loss of the binding affinity and enzyme activity. Herein, we present the development of an alkaline phosphatase-fused repebody as a new format of immuno-reagent for immunoassays. A repebody specifically binding to human TNF-α (hTNF-α) was selected through a phage display, and its binding affinity was increased up to 49 nM using a modular engineering approach. A monomeric alkaline phosphatase (mAP), which was previously isolated from a metagenome library, was genetically fused to the repebody as a signal generator, and the resulting repebody-mAP fusion protein was used for direct and sandwich immunoassays of hTNF-α. We demonstrate the utility and potential of the repebody-mAP fusion protein as an immuno-reagent by showing the sensitivity of 216 pg mL{sup −1} for hTNF-α in a sandwich immunoassay. Furthermore, this repebody-mAP fusion protein enabled the detection of hTNF-α spiked in a serum-supplemented medium with high accuracy and reproducibility. It is thus expected that a mAP-fused repebody can be broadly used as an immuno-reagent in immunoassays. - Highlights: • A human TNF-α (hTNF-α)-specific repebody was selected using a phage display. • A monomeric alkaline phosphatase (mAP) was genetically fused to the repebody. • mAP-fused repebody enabled detection of hTNF-α with high sensitivity and accuracy. • mAP-fused repebody can be widely used as a new immuno-reagent in immunoassays.

  6. Development of an immunoassay for determination of 2,4-dichlorophenoxyacetic acid (2,4-D) based upon the recombinant Fab fragment of 2,4-D specific antibody

    Science.gov (United States)

    Nguyen, Van C.; Nguyen, Thi D. T.; Dau, Hung A.; Tham, Thu N.; Quyen, Dinh T.; Bachmman, Till; Schmid, Rolf D.

    2001-09-01

    To develop an immunoassay and further an immunosensor for 2,4-D based upon recombinant antibody, the Fab fragments of 2,4-D specific antibody were expressed in E. coli. Western blotting analysis of the periplasmic cell fractions shown that under the non-reducing condition only a single protein band at a molecular mass of 45-kDa, corresponding to the whole Fab fragment was detected. Antigen binding activity for 2,4-D was found only in the extract of cells bearing the 2,4-D plasmid. An immunoassay based on the competitive reaction of 2,4-D and enzyme tracer with 2,4-D Fab fragments immobilized on micro titer plates via rabbit anti-mouse IgC was developed. Using this assay, 2,4-D could be detected at concentration range of 0.5 (mu) g/1 to 10(mu) g/1. The center point of the 2,4-D test was found at a concentration of 5 (mu) g/l. The assay was applied for detection of 2,4-D in spiked orange samples, resulting in recovery rate of 90 percent. The immunoassay could be applied to monitor human exposure to 2,4-D from contamination in fruit samples.

  7. Immobilization of antibodies and enzyme-labeled antibodies by radiation polymerization

    International Nuclear Information System (INIS)

    Kumakura, M.; Kaetsu, I.; Suzuki, M.; Adachi, S.

    1983-01-01

    Immobilization of antibodies and enzyme-labeled antibodies by radiation polymerization at low temperatures was studied. The antibody activity of antibody was not affected by irradiation at an irradiation dose of below 8 MR and low temperatures. Immobilization of peroxidase-labeled anti-rabbit IgG goat IgG, anti-peroxidase, peroxidase, and anti-alpha-fetoprotein was carried out with hydrophilic and hydrophobic monomers. The activity of the immobilized enzyme-labeled antibody membranes varied with the thickness of the membranes and increased with decreasing membrane thickness. The activity of the immobilized antibody particles was varied by particle size. Immobilized anti-alpha-fetoprotein particles and membranes can be used for the assay of alpha-fetoprotein by the antigen-antibody reaction, such as a solid-phase sandwich method with high sensitivity

  8. Characterization of hapten-protein conjugates: antibody generation and immunoassay development for chlorophenoxyacetic acid pesticides.

    Science.gov (United States)

    Boro, Robin C; Singh, K Vikas; Suri, C Raman

    2009-01-01

    The generation of specific and sensitive antibodies against small molecules is greatly dependent upon the characteristics of the hapten-protein conjugates. In this study, we report a new fluorescence-based method for the characterization of hapten-protein conjugates. The method is based on an effect promoted by hapten-protein conjugation density upon the fluorescence intensity of the intrinsic tryptophan chromophore molecules of the protein. The proposed methodology is applied to quantify the hapten-protein conjugation density for two different chlorophenoxyacetic acid pesticides, 2,4-dichlorophenoxyacetic acid (2,4-D) and 2,4-dichlorophenoxybutyric acid (2,4-DB), coupled to carrier protein. Highly sensitive anti-2,4-D and anti-2,4-DB antibodies were obtained using these well-characterized hapten-protein conjugates. The generated antibodies were used in an immunoassay format demonstrating inhibitory concentration (IC50) values equal to 30 and 7 ng/mL for 2,4-D and 2,4-DB, respectively. Linearity was observed in the concentration range between 0.1-500 nglmL with LODs around 4 and 3 ng/mL for 2,4-D and 2,4-DB, respectively, in standard water samples. The proposed method was successfully applied for the determination of the extent of hapten-protein conjugation to produce specific antibodies for immunoassay development against pesticides.

  9. Correlation of antinuclear antibody immunofluorescence patterns with immune profile using line immunoassay in the Indian scenario

    Directory of Open Access Journals (Sweden)

    Sebastian Wendy

    2010-07-01

    Full Text Available Background: Immunity status, individual response to disease and types of antibodies produced are well known to vary from person to person, place to place and probably from population to population. A broad spectrum of specific auto antibodies that have so far been associated with specific rheumatic diseases, as noted in Western literature, has been well taken as a reference standard all over the world. There is neither research work nor any data correlating the auto antibodies and their antinuclear antibody (ANA patterns with the immunoprofile in the Indian population to date. Aims: To understand a definite association between ANA patterns and specific antibodies in the serum in the Indian study population and to document similarities / differences with the West. Settings and Design: This prospective and retrospective double blind study was undertaken on the South Indian population referred for ANA testing by Indirect Immunofluorescence method and by immunoline methods. Materials and Methods: Serum samples of patients from a random South Indian population who sought medical help for rheumatic disease were subjected for ANA testing by indirect immunofluorescence (IIF method and line immunoassay during the study period of 27 months. Serum samples were processed in dilution of 1:100 using HEp - 2010 / liver biochip (Monkey (EUROIMMUN AG. The serum samples which were further processed for line immunoassay were treated in 1:100 dilution on nylon strips coated with recombinant and purified antigens as discrete lines with plastic backing (EUROIMMUN AG coated with antigens nRNP / Sm, Sm, SSA, Ro-52, SSB, Scl-70, PM-Scl, PCNA, Jo-1, CENP-B, dsDNA, nucleosomes, histones, ribosomal protein-P, anti-mitochondrial antibodies (AMA-M2 along with a control band. The analysis was done by comparing the intensity of the reaction with positive control line by image analysis. Results: The antinuclear antibody indirect immunofluorescence (ANA - IIF patterns obtained

  10. Flotation Immunoassay: Masking the Signal from Free Reporters in Sandwich Immunoassays.

    Science.gov (United States)

    Chen, Hui; Hagström, Anna E V; Kim, Jinsu; Garvey, Gavin; Paterson, Andrew; Ruiz-Ruiz, Federico; Raja, Balakrishnan; Strych, Ulrich; Rito-Palomares, Marco; Kourentzi, Katerina; Conrad, Jacinta C; Atmar, Robert L; Willson, Richard C

    2016-04-14

    In this work, we demonstrate that signal-masking reagents together with appropriate capture antibody carriers can eliminate the washing steps in sandwich immunoassays. A flotation immunoassay (FI) platform was developed with horseradish peroxidase chemiluminescence as the reporter system, the dye Brilliant Blue FCF as the signal-masking reagent, and buoyant silica micro-bubbles as the capture antibody carriers. Only reporters captured on micro-bubbles float above the dye and become visible in an analyte-dependent manner. These FIs are capable of detecting proteins down to attomole levels and as few as 10(6) virus particles. This signal-masking strategy represents a novel approach to simple, sensitive and quantitative immunoassays in both laboratory and point-of-care settings.

  11. Designing novel nano-immunoassays: antibody orientation versus sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Puertas, S; Moros, M; Fernandez-Pacheco, R; Ibarra, M R; Grazu, V; De la Fuente, J M, E-mail: vgrazu@unizar.e, E-mail: jmfuente@unizar.e [Instituto de Nanociencia de Aragon (INA), Universidad de Zaragoza, Campus RIo Ebro, EdifIcio I-D, Mariano Esquillor, s/n, 50018 Zaragoza (Spain)

    2010-12-01

    There is a growing interest in the use of magnetic nanoparticles (MNPs) for their application in quantitative and highly sensitive biosensors. Their use as labels of biological recognition events and their detection by means of some magnetic method constitute a very promising strategy for quantitative high-sensitive lateral-flow assays. In this paper, we report the importance of nanoparticle functionalization for the improvement of sensitivity for a lateral-flow immunoassay. More precisely, we have found that immobilization of IgG anti-hCG through its polysaccharide moieties on MNPs allows more successful recognition of the hCG hormone. Although we have used the detection of hCG as a model in this work, the strategy of binding antibodies to MNPs through its sugar chains reported here is applicable to other antibodies. It has huge potential as it will be very useful for the development of quantitative and high-sensitive lateral-flow assays for its use on human and veterinary, medicine, food and beverage manufacturing, pharmaceutical, medical biologics and personal care product production, environmental remediation, etc.

  12. Comparison of a neutralization enzyme immunoassay and an enzyme-linked immunosorbent assay for evaluation of immune status of children vaccinated for mumps.

    Science.gov (United States)

    Harmsen, T; Jongerius, M C; van der Zwan, C W; Plantinga, A D; Kraaijeveld, C A; Berbers, G A

    1992-01-01

    A 50% neutralization enzyme immunoassay (N50-EIA) was compared with an indirect enzyme-linked immunosorbent assay (ELISA) for determining mumps virus antibodies in three consecutive serum samples from 138 children vaccinated with a live mumps vaccine at the age (in years) of 1.5. By the N50-EIA, most (132 of 138) preserum samples did not show neutralizing activity. Eight to 12 weeks after vaccination, 17 of the children were still negative, but only 7 remained so after 2.5 years, resulting in a seroconversion rate of 125 of 132 (95%). Over the same period, the neutralization geometric mean titer rose from 3.6 to 9.9. By an indirect ELISA, 128 of 138 preserum samples were found negative. The early and late postvaccination sera of 8 children were ELISA negative, resulting in a seroconversion rate of 120 of 128 (94%). Only two children remained seronegative by both methods. Seven of the late postvaccination serum samples yielded noncorresponding results, reflecting 95% correlation between both methods. Due to cross-reactivity with parainfluenza viruses, the ELISA proved to be less specific, but on the other hand, it showed a greater sensitivity than the N50-EIA. PMID:1500523

  13. Immunoassays in Biotechnology

    Science.gov (United States)

    Immunoassays have broad applications for a wide variety of important biological compounds and environmental contaminants. Immunoassays can detect the presence of an antigen in the human body, a pollutant in the environment, or a critical antibody in a patient’s serum to develop a...

  14. A double antibody radioimmunoassay specific for placental alkaline phosphatase

    International Nuclear Information System (INIS)

    Dass, S.; Bagshawe, K.D.

    1984-01-01

    Placental alkaline phosphatase (PLAP) is normally found in enzymically measurable amounts in second and third trimester pregnancy serum. Its occurrence in sera and tumours from patients with malignant disease has led to the development of methods to specifically identify and quantitate the enzyme. Recently immunological techniques have been used, employing antibodies raised to purified PLAP; these include solid phase radioimmunoassays and enzyme-immunoassay. The development of a sensitive, specific, automated double-antibody radioimmunoassay for the measurement of PLAP in serum is reported. (Auth.)

  15. Optimization of condition for conjugation of enrofloxacin to enzymes in chemiluminescence enzyme immunoassay

    Science.gov (United States)

    Yu, Songcheng; Yu, Fei; Zhang, Hongquan; Qu, Lingbo; Wu, Yongjun

    2014-06-01

    In this study, in order to find out a proper method for conjugation of enrofloxacin to label enzymes, two methods were compared and carbodiimide condensation was proved to be better. The results showed that the binding ratio of enrofloxacin and alkaline phosphatase (ALP) was 8:1 and that of enrofloxacin and horseradish peroxidase (HRP) was 5:1. This indicated that conjugate synthesized by carbodiimide condensation was fit for chemiluminescence enzyme immunoassay (CLEIA). Furthermore, data revealed that dialysis time was an important parameter for conjugation and 6 days was best. Buffer to dilute conjugate had little effect on CLEIA. The storage condition for conjugates was also studied and it was shown that the conjugate was stable at 4 °C with no additive up to 30 days. These data were valuable for establishing CLEIA to quantify enrofloxacin.

  16. Oligopeptide-based enzyme immunoassay for ovine lentivirus antibody detection.

    OpenAIRE

    Kwang, J; Torres, J V

    1994-01-01

    Ovine progressive pneumonia virus (OPPV) is a lentivirus which causes a progressive disease in sheep. Immunodominant epitopes have been identified in the envelope gp40 glycoprotein. Synthetic peptides representing these regions are able to detect the presence of OPPV antibodies in 96% of infected sheep.

  17. Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3

    Directory of Open Access Journals (Sweden)

    Qian-Yun Zhang

    2011-08-01

    Full Text Available Glypican-3 (GPC3 is reported as a great promising tumor marker for hepatocellular carcinoma (HCC diagnosis. Highly sensitive and accurate analysis of serum GPC3 (sGPC3, in combination with or instead of traditional HCC marker alpha-fetoprotein (AFP, is essential for early diagnosis of HCC. Biomaterial-functionalized magnetic particles have been utilized as solid supports with good biological compatibility for sensitive immunoassay. Here, the magnetic nanoparticles (MnPs and magnetic microparticles (MmPs with carboxyl groups were further modified with streptavidin, and applied for the development of chemiluminescence enzyme immunoassay (CLEIA. After comparing between MnPs- and MmPs-based CLEIA, MnPs-based CLEIA was proved to be a better method with less assay time, greater sensitivity, better linearity and longer chemiluminescence platform. MnPs-based CLEIA was applied for detection of sGPC3 in normal liver, hepatocirrhosis, secondary liver cancer and HCC serum samples. The results indicated that sGPC3 was effective in diagnosis of HCC with high performance. Keywords: Magnetic nanoparticle, Magnetic microparticle, Chemiluminescence enzyme immunoassay, Glypican-3, Hepatocellular carcinoma

  18. Serological discrimination by indirect enzyme immunoassay between the antibody response to Brucella sp and Yersinia enterocolitica O : 9 in cattle and pigs

    DEFF Research Database (Denmark)

    Nielsen, K.; Smith, P.; Yu, W.

    2006-01-01

    A rapid, inexpensive and rugged serological test that distinguishes cattle and swine infected with Brucella sp. or Yersinia enterocolitica O:9 is described. The test protocol, which is an indirect enzyme immunoassay uses a high concentration of divalent cation chelating agents to minimize binding...... with Brucella sp. Sera from 58 cattle and 38 swine exposed to Y. enterocolitica O:9 were negative while only 20 sera from 121 'false positive' reactors of unspecified origin gave low level positive reactions, eliminating 84% of the false positive reactions. Crown...

  19. Bead-based immunoassays

    NARCIS (Netherlands)

    Wal, van der F.J.; Bergervoet, J.H.W.; Achterberg, R.P.; Haasnoot, W.

    2014-01-01

    Since the first immunoassay with (radioactive) labeled antibodies in the middle of the 20th century [1], many different formats on various platforms have been developed, using antibodies for capture and/or detection. If antibodies are used to capture compounds, a support, such as the wall of a

  20. False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.

    Science.gov (United States)

    Katz, Alan R; Komeya, Alan Y; Tomas, Juval E

    2017-06-01

    We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.

  1. Single-dilution enzyme-linked immunosorbent assay for quantification of antigen-specific salmonid antibody

    Science.gov (United States)

    Alcorn, S.W.; Pascho, R.J.

    2000-01-01

    An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.

  2. Ultrasensitive electrochemical immunoassay of staphylococcal enterotoxin B in food using enzyme-nanosilica-doped carbon nanotubes for signal amplification.

    Science.gov (United States)

    Tang, Dianping; Tang, Juan; Su, Biling; Chen, Guonan

    2010-10-27

    A new sandwich-type electrochemical immunoassay for ultrasensitive detection of staphylococcal enterotoxin B (SEB) in food was developed using horseradish peroxidase-nanosilica-doped multiwalled carbon nanotubes (HRPSiCNTs) for signal amplification. Rabbit polyclonal anti-SEB antibodies immobilized on the screen-printed carbon electrode (SPCE) and covalently bound to the HRPSiCNTs were used as capture antibodies and detection antibodies, respectively. In the presence of SEB analyte, the sandwich-type immunocomplex could be formed between the immobilized anti-SEB on the SPCE and anti-SEB-labeled HRPSiCNTs, and the carried HRP could catalyze the electrochemical reduction of H2O2 with the help of thionine. The high content of HRP in the HRPSiCNTs could greatly amplify the electrochemical signal. Under optimal conditions, the reduction current increased with the increase of SEB in the sample, and exhibited a dynamic range of 0.05-15 ng/mL with a low detection limit (LOD) of 10 pg/mL SEB (at 3σ). Intra- and interassay coefficients of variation were below 10%. In addition, the assay was evaluated with SEB spiked samples including watermelon juice, soymilk, apple juice, and pork food, receiving excellent correlation with results from commercially available enzyme-linked immunosorbent assay (ELISA).

  3. [Fundamental evaluation of apolipoprotein B-48 by chemiluminescence enzyme immunoassay--identification of apolipoprotein B-48 with immunoblotting].

    Science.gov (United States)

    Sato, Itsuko; Fujioka, Yoshio; Hayashi, Fujio; Mukai, Masahiko; Kawano, Seiji; Ishikawa, Yuichi; Yamashita, Shizuya; Kumagai, Shunichi

    2007-06-01

    Apolipoprotein B-48 (apo B-48) is a constituent of chylomicrons and chylomicron remnants, and its fasting concentration has been reported to be a marker of postprandial hyperlipidemia, which is thought to be a risk factor of atherosclerosis. We evaluated the serum apo B-48 concentrations by chemiluminescence enzyme immunoassay (CLEIA), which was recently introduced as Lumipulse f fully automated immunosaasy analyzer by Fujirebio Inc (Tokyo, Japan), and performed immunoblotting on agarose gel electrophoresis with anti-apo B-48 antibody. Apo B-48 assay was intra-assay reproducible (CVs: 1.9-3.1%) and inter-assay reproducible (CVs: 2.2-4.4%). The assay range for apo B-48 was from 0.2 to 40.0 microg/ml. The effects of interfering substances such as free/conjugated birirubin, hemoglobin, Intrafat, ascorbic acid and rheumatoid factor were negligible. For storage, it was preferable to freeze, and to avoid frozen-thaw process as much as possible. Anti-apo B-48 antibody was reactive over a wide range from origin to the position of very-low-density lipoproteins in immunoblotting after agarose gel electrophoresis. Apo B-48 measurement by CLEIA was feasible to clinical use for the assessment of lipoprotein metabolism.

  4. Evaluation and Comparison of Enzyme Immunoassay (Eia and Acid Fast Staining with Confirmation by Immunofluorescent Antibody Assay for Detection of Cryptosporidium Species in Infants and Young Children.

    Directory of Open Access Journals (Sweden)

    D Dorostcar Moghaddam

    2005-01-01

    Full Text Available Introduction: Cryptosporidiosis is prevalent world wide, causing a variety of problems ranging from acute, self-limiting diarrhea to fatal cases in immunocompromised persons, particulary those with acquired immunodeficiency (AIDS. Diagnosis of Cryptosporidium is made by identification of oocysts in stool specimens. The detection is most commonly made by the acid-fast staining method followed by microscopic examination which has low specificity and sensitivity. Material and Methods: In the present study, we evaluated diagnostic utility of a commercially available enzyme immunoassay (EIA, which detects Cryptosporidium-Specific antigen (CSA in 204 unprocessed stool specimens obtained from patients less than 3 years of age. Results: When compared with the routine screening procedure applied in this field study (screening by acid-fast staining and microscopy after concentration of positive results by IFA, both sensitivity and specificity were 98%. Of the 139 specimens negative by microscopy, 13 (9.3% were positive by EIA, 11 of which were confirmed by inhibition with antibody to Cryptosporidia-specific antigen. Conclusion: The EIA is an important tool for identifying Cryptosporidium in fecal specimens in field studies since it is sensitive, specific, simple to use and unaffected by the presence of a preservative.

  5. Challenges, pitfalls and surprises: development and validation of a monoclonal antibody for enzyme immunoassay of the steroid 1α-hydroxycorticosterone in elasmobranch species.

    Science.gov (United States)

    Wheaton, Catharine J; Mylniczenko, Natalie D; Rimoldi, John M; Gadepalli, Rama S V S; Hart, R; O'Hara, Bobbi R; Evans, Andrew N

    2018-01-31

    Sharks and rays are popular species used in wildlife ecotourism and aquariums to educate the public on the behavior, ecology and conservation challenges of elasmobranchs. To understand long-term physiological health and welfare under varying social and husbandry conditions, we developed and validated an enzyme immunoassay (EIA) to measure stress/ionoregulatory hormones in managed and semi-free range southern rays (Hypanus americanus). Banked serum and interrenal samples from 27 female rays managed at Disney's The Seas with Nemo and Friends® and Castaway Cay were used to evaluate measurement of 1α-hydroxycorticosterone (1αOHB) relative to corticosterone (B). Although commercial EIAs are available for B, those tested exhibit only low relative cross-reactivity to 1αOHB (3-5%). To improve measurement of 1αOHB, we developed a monoclonal antibody using a synthesized 1αOHB-derivative for evaluation using high-performance liquid chromatography (HPLC) and EIA. Relative displacements of cross-reactant compounds showed that the antibody had good sensitivity for the target antigen 1αOHB, and low sensitivity to related steroids (desoxycorticosterone and B), but greater sensitivity to 11-dehydrocorticosterone. Tests of competitive vs. noncompetitive EIA formats, reagent titration, and incubation times of the antibody and conjugate were used to optimize sensitivity, repeatability and precision of measured 1αOHB in standards and samples (4 ng/ml, 90% binding). Tests of sample pre-treatment (pH adjustment) and extraction with varying solvent polarity were used to optimize measurement of 1αOHB in <1 ml (serum) or 1 g (interrenal) samples. HPLC analysis revealed the 1αOHB EIA to be superior for measurement of 1αOHB compared to use of a B EIA with or without HPLC fractioning. Results may prove useful for extrapolation to guide best practices for 1αOHB measurement in other elasmobranch species. Improved measurement of stress/ionoregulatory hormones in sharks and rays

  6. Two competitive enzyme immunoassays for the detection of IgG class antibodies to hepatitis a antigen

    Directory of Open Access Journals (Sweden)

    Claudia Lamarca Vitral

    1991-06-01

    Full Text Available Two competitive enzyme immunoassays (EIA techniques were developed: in the first (COMP-1, test sera were added together with HAV antigen on anti-HAV IgG-coated wells followed by an anti-HA VHRP conjugate; in the second (COMP-2, test sera and anti-HA VHRP conjugate competed for HAV epitopes previously adsorbed to anti-HA V IgG-coated wells. Both procedures used tetramethylbenzidine (TMB as a substrate. Both competitive tests were shown to be reproducible and suitable for routine diagnosis and research purposes.Foram desenvolvidos dois ensaios imunoenzimáticos (EIA competitivos: no primeiro (COMP-1 colocou-se numa placa sensibilizada com anti-HAVIgG as amostras teste juntamente como antígeno HA Vea seguir o conjugado anti-HA VHRP; no segundo (COMP-2, as amostras teste e o conjugado anti-HAV HRP competem pelos epitopos do antígeno HAV previamente absorvido na placa sensibilizada do anti-HAV IgG. O substrato utilizado foi tetrametilbenzidina (TMB. Ambas as técnicas mostraram ser produtíveis e aplicáveis para fins de diagnóstico e pesquisa.

  7. Comparison of enzyme immunoassays for the diagnosis of bovine brucellosis

    International Nuclear Information System (INIS)

    Nielsen, K.; Kelly, L.; Gall, D.; Balsevicius, S.; Bosse, J.; Kelly, W.; Nicoletti, P.

    1998-01-01

    The indirect enzyme immunoassay for measurement of bovine antibody to Brucella abortus was tested on 15,716 Canadian sera to assess the specificity. These sera were also tested by the buffered plate antigen test. Two ELISA formats were used for assessment of data: the targeting procedure using a positive control serum allowed to develop to an optical density of 1.0 and the use of a positive control serum to determine relative positivity at a set time. Two different cut-off values were also assessed for each assay. A total of 763 sera gave reactions above established cut-off values in the ELISA while 216 were positive in the buffered plate antigen test (BPAT). A modification of the indirect ELISA employed divalent cation chelating agents (EDTA/EGTA) incorporated into the serum incubation stage to eliminate some non-specific reactions. This method was applied only to the 763 indirect ELISA reactor sera and it eliminated all but 93 or 37, depending on the cut-off selected, of the reactions. Sensitivity was assessed by testing 424 sera from Brucella abortus culture positive cattle. The indirect ELISA classified all 424 sera as positive by either method of data handling and with or without addition of EDTA/EGTA for a specificity estimate of 100%. In the BPAT, 412 sera gave a positive agglutination reaction. Ten percent of the 15,716 sera were randomly selected and tested by two different competitive ELISAs and by the complement fixation test (CFT). One competitive ELISA used Brucella abortus O-polysaccharide as the antigen and an enzyme conjugated monoclonal antibody to the O-polysaccharide for competition and detection. Of the sera tested, 34 gave false positive reactions. On a retest, the false positive reactions were reduced to 2. The second competitive ELISA used lipopolysaccharide as the antigen, a different monoclonal antibody but also specific for the O-polysaccharide for competition and commercially available goat anti-mouse IgG enzyme conjugate for detection

  8. Ervaringen met een solid phase enzyme immunoassay voor het aantonen van gonorroe bij promiscue vrouwen

    NARCIS (Netherlands)

    Ulsen; J.van*; Michel; M.F.*; Strik; R.van*; Joost; T.H.van*; Stolz; E.*; Eijk; R.V.W.van

    1985-01-01

    De Gonozyme test (Abbott Laboratories), een nieuwe enzyme immunoassay (EIA) voor het aantonen van Neisseria gonorrhoeae werd geevalueerd in een grote groep promiscue vrouwen. Als de EIA werd uitgevoerd met materiaal afkomstig van de cervix, bedroeg de prevalentie van gonorroe 8,2%. Vergeleken

  9. Clinical comparison of the Treponema pallidum CAPTIA syphilis-G enzyme immunoassay with the fluorescent treponemal antibody absorption immunoglobulin G assay for syphilis testing.

    Science.gov (United States)

    Halling, V W; Jones, M F; Bestrom, J E; Wold, A D; Rosenblatt, J E; Smith, T F; Cockerill, F R

    1999-10-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of >/=0.650 and 0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests

  10. Rapid micromotor-based naked-eye immunoassay.

    Science.gov (United States)

    de Ávila, Berta Esteban-Fernández; Zhao, Mingjiao; Campuzano, Susana; Ricci, Francesco; Pingarrón, José M; Mascini, Marcello; Wang, Joseph

    2017-05-15

    A dynamic micromotor-based immunoassay, exemplified by cortisol detection, based on the use of tubular micromotors functionalized with a specific antibody is described. The use of antibody-functionalized micromotors offers huge acceleration of both direct and competitive cortisol immunoassays, along with greatly enhanced sensitivity of direct and competitive immunoassays. The dramatically improved speed and sensitivity reflect the greatly increased likelihood of antibody-cortisol contacts and fluid mixing associated with the dynamic movement of these microtube motors and corresponding bubble generation that lead to a highly efficient and rapid recognition process. Rapid naked-eye detection of cortisol in the sample is achieved in connection to use of horseradish peroxidase (HRP) tag and TMB/H 2 O 2 system. Key parameters of the competitive immunoassay (e.g., incubation time and reaction volume) were optimized. This fast visual micromotor-based sensing approach enables "on the move" specific detection of the target cortisol down to 0.1μgmL -1 in just 2min, using ultrasmall (50µL) sample volumes. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Domestic cat microsphere immunoassays: detection of antibodies during feline immunodeficiency virus infection.

    Science.gov (United States)

    Wood, Britta A; Carver, Scott; Troyer, Ryan M; Elder, John H; VandeWoude, Sue

    2013-10-31

    Microsphere immunoassays (MIAs) allow rapid and accurate evaluation of multiple analytes simultaneously within a biological sample. Here we describe the development and validation of domestic cat-specific MIAs for a) the quantification of total IgG and IgA levels in plasma, and b) the detection of IgG and IgA antibodies to feline immunodeficiency virus (FIV) capsid (CA) and surface (SU) proteins, and feline CD134 in plasma. These assays were used to examine the temporal antibody response of domestic cats infected with apathogenic and pathogenic FIVs, and domestic cats infected with parental and chimeric FIVs of varying pathogenicity. The results from these studies demonstrated that a) total IgG antibodies increase over time after infection; b) α-CA and α-SU IgG antibodies are detectable between 9 and 28 days post-infection and increase over time, and these antibodies combined represent a fraction (1.8 to 21.8%) of the total IgG increase due to infection; c) measurable α-CD134 IgG antibody levels vary among individuals and over time, and are not strongly correlated with viral load; d) circulating IgA antibodies, in general, do not increase during the early stage of infection; and e) total IgG, and α-CA and α-SU IgG antibody kinetics and levels vary with FIV viral strain/pathogenicity. The MIAs described here could be used to screen domestic cats for FIV infection, and to evaluate the FIV-specific or total antibody response elicited by various FIV strains/other diseases. © 2013.

  12. The clinical application of fluorescent-enzyme immunoassay to detect human thyroid peroxidase autoantibody quantitatively

    International Nuclear Information System (INIS)

    Chai Jinyan; Fang Peihua; Li Ning; Zhang Yanli

    2010-01-01

    Objective: To establish a fluorescent-enzyme immunoassay (FEIA) with recombinant human thyroid peroxidase (hTPO) as the antigen. Methods: Sera of 326 healthy people, 119 cases of Hashimoto's thyroiditis (HT), 116 cases of Graves disease (untreated), 28 cases of nodular goiter, 10 ca-ses of subacute thyroiditis and 6 cases of simple goiter were measured by the FEIA with recombinant hTPO as the antigen. Rrank sum test and χ 2 -test were used in inter-groups. Results: (1) Concentration above 4000 U/L was considered to be positive. (2) The intra-assay coefficient of variation (CV) and the inter-as-say CV were 4.59% ∼ 6.52% and 17.37% ∼ 17.45%. (3) The values measured by the FEIA were positively correlated with the values measured by hTPO antibody (hTPOAb) commercial kit (r=0.80, P 2 = 53.45, 39.30, 15.41 and 21.74, all P < 0.01). Conclusions: The method can be applied in the serum measurement of thyroid disease. HT presented the highest positive rate, therefore, the FEIA was an effective method in diagnosing HT. (authors)

  13. [DIAGNOSTIC VALUE OF COMBINED USE OF COMBINED METHOD OF ENZYME IMMUNOASSAY AND POLYMERASE CHAIN REACTION TO DETECT OF INTRAUTERINE FETAL INFECTION BY PARVOVIRUS B19].

    Science.gov (United States)

    Bondarenko, N P; Lakatosh, V P; Lakatosh, P V; Malanchuk, O B; Poladich, I V

    2015-01-01

    The combined method of diagnosis parvovirus infection during pregnancy by maternal serum enzyme immunoassay and deoxyribonucleic acid isolation parvovirus B19 polymerase chain reaction in amnniotic fluid and fetal cord blood newborns, can diagnose vertical transmission and anticipate a negative effect on the fetus parvovirus. Lack of maternal IgM antibodies in serum due to parvovirus seroconversion during pregnancy does not exclude the persistence of the virus in the fetus. To analyze the diagnostic value of the method for determining the LHP parvovirus B19 DNA in the amniotic fluid, umbilical cord blood of newborns to determine vertical transmission of parvovirus infection when infected mothers B19 during pregnancy.

  14. Thermophilic Campylobacter spp. in turkey samples: evaluation of two automated enzyme immunoassays and conventional microbiological techniques

    DEFF Research Database (Denmark)

    Borck, Birgitte; Stryhn, H.; Ersboll, A.K.

    2002-01-01

    Aims: To determine the sensitivity and specificity of two automated enzyme immunoassays (EIA), EiaFoss and Minividas, and a conventional microbiological culture technique for detecting thermophilic Campylobacter spp. in turkey samples. Methods and Results: A total of 286 samples (faecal, meat...

  15. Study on the determination of human placental lactogen (HPL) using an enzyme-immunoassay. Comparison with a commercial radio-immunoassay in the course of normal pregnancies

    International Nuclear Information System (INIS)

    Schneider, B.

    1982-01-01

    A novel enzyme-immunoassay (EIA) for determining human placental lactogen (HPL) was studied for its practicability and quality. The precision of the system in series was tested by using a serum taken each in the 19th, 29th and 40th pregnancy week. A normal range graph between the 10th and the 40th pregnancy week (10 sera per pregnancy week) was established from 310 sera of normal-course pregnancies. The graph practically agreed with the known RIA-established graphs. When comparing with a radio-immunoassay for HPL of routine application and known quality criteria, r=0.93 indicated a close correlation of the values found. (orig./MG) [de

  16. Multiplex detection of plant pathogens using a microsphere immunoassay technology.

    Directory of Open Access Journals (Sweden)

    Ratthaphol Charlermroj

    Full Text Available Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac, chilli vein-banding mottle virus (CVbMV, potyvirus, watermelon silver mottle virus (WSMoV, tospovirus serogroup IV and melon yellow spot virus (MYSV, tospovirus. An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour was much shorter than that of ELISA (4 hours. This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection.

  17. Multiplex detection of plant pathogens using a microsphere immunoassay technology.

    Science.gov (United States)

    Charlermroj, Ratthaphol; Himananto, Orawan; Seepiban, Channarong; Kumpoosiri, Mallika; Warin, Nuchnard; Oplatowska, Michalina; Gajanandana, Oraprapai; Grant, Irene R; Karoonuthaisiri, Nitsara; Elliott, Christopher T

    2013-01-01

    Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac), chilli vein-banding mottle virus (CVbMV, potyvirus), watermelon silver mottle virus (WSMoV, tospovirus serogroup IV) and melon yellow spot virus (MYSV, tospovirus). An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE)-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA) when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour) was much shorter than that of ELISA (4 hours). This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection.

  18. Part-per-trillion level detection of estradiol by competitive fluorescence immunoassay using DNA/dye conjugate as antibody multiple labels.

    Science.gov (United States)

    Zhu, Shengchao; Zhang, Qin; Guo, Liang-Hong

    2008-08-22

    Fluorescent organic dyes are currently the standard signal-generating labels used in microarray quantification. However, new labeling strategies are needed to meet the demand for high sensitivity in the detection of low-abundance proteins and small molecules. In this report, a long-chain DNA/dye conjugate was used to attach multiple fluorescence labels on antibodies to improve signal intensity and immunoassay sensitivity. Compared with the 30 base-pair (bp) oligonucleotide used in our previous work [Q. Zhang, L.-H. Guo, Bioconjugate Chem. 18 (2007) 1668-1672], conjugation of a 219 bp DNA in solution with a fluorescent DNA binder SYBR Green I resulted in more than sixfold increase in signal intensity, consistent with the increase in bp number. In a direct immunoassay for the detection of goat anti-mouse IgG in a mouse IgG-coated 96-well plate, the long DNA conjugate label also produced higher fluorescence than the short one, accompanied by about 15-fold improvement in the detection limit. To demonstrate its advantage in real applications, the DNA/dye conjugate was employed in the competitive immunoassay of 17beta-estradiol, a clinically and environmentally important analyte. The biotin-terminated DNA was attached to biotinylated anti-estradiol antibody through the biotin/streptavidin/biotin bridge after the immuno-reaction was completed, followed by conjugation with SYBR Green I. The limit of detection for 17beta-estradiol is 1.9 pg mL(-1), which is 200-fold lower than the assay using fluorescein-labeled antibodies. The new multiple labeling strategy uses readily available reagents, and is also compatible with current biochip platform. It has great potential in the sensitive detection of protein and antibody microarrays.

  19. Anti-idiotypic nanobody-alkaline phosphatase fusion proteins: Development of a one-step competitive enzyme immunoassay for fumonisin B_1 detection in cereal

    International Nuclear Information System (INIS)

    Shu, Mei; Xu, Yang; Liu, Xing; Li, Yanping; He, Qinghua; Tu, Zhui; Fu, Jinheng; Gee, Shirley J.; Hammock, Bruce D.

    2016-01-01

    A rapid and sensitive one-step competitive enzyme immunoassay for the detection of FB_1 was developed. The anti-idiotypic nanobody–alkaline phosphatase (Ab2β−Nb−AP) was validated by the AP enzyme activity and the properties of bounding to anti-FB1-mAb (3F11) through colorimetric and chemiluminescence analyses. The 50% inhibitory concentration and the detection limit (LOD) of colorimetric enzyme-linked immunosorbent assay (ELISA) for FB_1 were 2.69 and 0.35 ng mL"−"1, respectively, with a linear range of 0.93–7.73 ng mL"−"1. The LOD of the chemiluminescence ELISA (CLIA) was 0.12 ng mL"−"1, and the IC_5_0 was 0.89 ± 0.09 ng mL"−"1 with a linear range of 0.29–2.68 ng mL"−"1. Compared with LC-MS/MS, the results of this assay indicated the reliability of the Ab2β−Nb−AP fusion protein based one-step competitive immunoassay for monitoring FB_1 contamination in cereals. The Ab2β−Nb−AP fusion proteins have the potential to replace chemically-coupled probes in competitive enzyme immunoassay systems. - Highlights: • Ab2β−Nb−AP has the potential to replace chemically-coupled probes. • Ab2β−Nb−AP is homogeneous enzyme-labelled antigen can be prepared reproducibly. • We developed a green and rapid one-step competitive enzyme immunoassay. • The sensitivity of one-step CLIA was 9-folds higher than two-step ELISA.

  20. The Use of Recombinant Hemagglutinine Protein of Rinderpest Virus in Enzyme Immunoassay

    OpenAIRE

    BULUT, Hakan; BOLAT, Yusuf

    2003-01-01

    In this study, Rinderpest virus (RPV) recombinant hemagglutinine protein (rH) fused with protein A region of Staphylococcus aureus was expressed in Escherichia coli and purified by IgG affinity chromatography. rH protein was also used to establish enzyme immunoassay. Therefore, to prevent IgG binding to the protein A the wells coated with the rH proteins were blocked by human serum. Afterwards, RPV antigens were added to the wells to evaluate this assay. To this end, serum from mice immunized...

  1. Development of an ultrasensitive immunoassay for detecting tartrazine.

    Science.gov (United States)

    Li, Zhuokun; Song, Shanshan; Xu, Liguang; Kuang, Hua; Guo, Shidong; Xu, Chuanlai

    2013-06-25

    We have developed an ultrasensitive indirect competitive enzyme-linked immunosorbent assay for the determination of tartrazine. Two carboxylated analogues of tartrazine with different spacer lengths, and one derivative from commercial tartrazine after a little chemical modification, were synthesized as haptens in order to produce antibodies specific to tartrazine. The effect of sulfonic acid groups on the hapten structure of tartrazine was also studied carefully for the first time. A most specific monoclonal antibody against tartrazine was created and exhibited an IC50 value of 0.105 ng/mL and a limit of detection of 0.014 ng/mL, with no cross-reactivity to other structurally-related pigments. The established immunoassay was applied to the determination of tartrazine in fortified samples of orange juice and in real positive samples of carbonated beverages.

  2. Nanobody medicated immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein.

    Science.gov (United States)

    Chen, Jing; He, Qing-hua; Xu, Yang; Fu, Jin-heng; Li, Yan-ping; Tu, Zhui; Wang, Dan; Shu, Mei; Qiu, Yu-lou; Yang, Hong-wei; Liu, Yuan-yuan

    2016-01-15

    Immunoassay for cancer biomarkers plays an important role in cancer prevention and early diagnosis. To the development of immunoassay, the quality and stability of applied antibody is one of the key points to obtain reliability and high sensitivity for immunoassay. The main purpose of this study was to develop a novel immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein (AFP) based on nanobody against AFP. Two nanobodies which bind to AFP were selected from a phage display nanobody library by biopanning strategy. The prepared nanobodies are clonable, thermally stable and applied in both sandwich enzyme linked immunoassay (ELISA) and immuno-PCR assay for ultrasensitive detection of AFP. The limit detection of sandwich ELISA setup with optimized nanobodies was 0.48ng mL(-1), and the half of saturation concentration (SC50) value was 6.68±0.56ng mL(-1). These nanobodies were also used to develop an immuno-PCR assay for ultrasensitive detection of AFP, its limit detection values was 0.005ng mL(-1), and the linear range was 0.01-10,000ng mL(-1). These established immunoassays based on nanobodies were highly specific to AFP and with negligible cross reactivity with other tested caner biomarkers. Furthermore, this novel concept of nanobodies mediated immunoassay may provide potential applications in a general method for the ultrasensitive detection of various cancer biomarkers. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Rapid determination of recent cocaine use with magnetic particles-based enzyme immunoassays in serum, saliva, and urine fluids.

    Science.gov (United States)

    Vidal, Juan C; Bertolín, Juan R; Bonel, Laura; Asturias, Laura; Arcos-Martínez, M Julia; Castillo, Juan R

    2016-06-05

    Cocaine is one of the most worldwide used illicit drugs. We report a magnetic particles-based enzyme-linked immunoassay (mpEIA) method for the rapid and sensitive determination of cocaine (COC) in saliva, urine and serum samples. Under optimized conditions, the limits of detections were 0.09ngmL(-1) (urine), 0.15ngmL(-1) (saliva), and 0.06ngmL(-1) COC (human serum). Sensitivities were in the range EC50=0.6-2.5ngmL(-1) COC. The cross-reactivity with the principal metabolite benzoylecgonine (BZE) was only 1.6%. Recovering percentages of doped samples (0, 10, 50, and 100ngmL(-1) of COC) ranged from about 86-111%. Some advantages of the developed mpEIA over conventional ELISA kits are faster incubations, improved reproducibility, and consumption of lower amounts of antibody and enzyme conjugates due to the use of magnetic beads. The reported method was validated following the guidelines on bioanalytical methods of the European Medicines Agency (2011). Unmetabolized COC detection has a great interest in pharmacological, pharmacokinetics, and toxicokinetics studies, and can be used to detect a very recent COC use (1-6h). Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Advanced techniques in immunoassay

    International Nuclear Information System (INIS)

    Toth, G.

    1982-01-01

    A brief overview of the development history of radioimmunoassay and related techniques with their theory and practice are given. A comparison of radioimmunoassay (RIA), enzyme immunoassay (EIA), spin immunoassay (SIA), sequential saturation analysis (SSA) etc., based on their main parameters, and their fields of application and recent trends are presented. (Sz.J.)

  5. Comparison of Salivary and Serum Enzyme Immunoassays for the Diagnosis of Helicobacter pylori Infection

    Directory of Open Access Journals (Sweden)

    John M Embil

    1998-01-01

    Full Text Available Infection with Helicobacter pylori has been established as an important risk factor for the development of peptic ulcer disease, gastritis and gastric cancer. The diagnosis of H pylori infection can be established by invasive or noninvasive techniques. Two noninvasive enzyme immunoassays (EIAs for antibody detection – HeliSal and Pylori Stat – were compared with histology. Both assays detect immunoglobulin (Ig G directed against purified H pylori antigen. The test populations consisted of 104 consecutive patients scheduled for upper gastrointestinal endoscopy. Of these patients, 97 (93% had symptoms compatible with peptic ulcer disease. Saliva and serum were collected simultaneously at the time of endoscopy. Salivary EIA had a sensitivity of 66%, specificity of 67%, positive predictive value of 67% and negative predictive value of 66% compared with the serum EIA, where the results were 98%, 48%, 64% and 96%, respectively. Although the salivary EIA is an appealing noninvasive test, it was not a sensitive and specific assay. The serum EIA also lacked specificity, but was highly sensitive with a good negative predictive value. Although a negative serum EIA rules out H pylori infection, a positive result must be interpreted in the clinical context and confirmed with a more specific measure.

  6. Plasma myelin basic protein assay using Gilford enzyme immunoassay cuvettes.

    Science.gov (United States)

    Groome, N P

    1981-10-01

    The assay of myelin basic protein in body fluids has potential clinical importance as a routine indicator of demyelination. Preliminary details of a competitive enzyme immunoassay for this protein have previously been published by the author (Groome, N. P. (1980) J. Neurochem. 35, 1409-1417). The present paper now describes the adaptation of this assay for use on human plasma and various aspects of routine data processing. A commercially available cuvette system was found to have advantages over microtitre plates but required a permuted arrangement of sample replicates for consistent results. For dose interpolation, the standard curve could be fitted to a three parameter non-linear equation by regression analysis or linearised by the logit/log transformation.

  7. Comparison of a Recombinant-antigen Enzyme Immunoassay with Treponema pallidum Hemagglutination Test for Serological Confirmation of Syphilis

    Directory of Open Access Journals (Sweden)

    Rodríguez Islay

    2002-01-01

    Full Text Available A recombinant-antigen enzyme immunoassay (EIA, BioSCREEN TM anti-Treponema pallidum, was compared favorably with the T. pallidum hemagglutination test, in the detection of specific antibodies in different groups of sera from patients with primary (n = 38, secondary (n = 10, early latent (n = 28 and congenital syphilis (n = 2, patients with leptospirosis ( n= 8, infectious mononucleosis (n = 7, hepatitis (n = 9, diabetes mellitus (n = 11, rheumatoid arthritis (n = 13, leprosy (n = 11, tuberculosis (n = 9, HIV/Aids ( n= 12, systemic lupus erythematosus (n = 4, rheumatic fever (n = 3, old-persons (n = 9, pregnant women (n = 29 and blood donors (n = 164. The coincidence between them was 95.1%. The sensitivity and specificity of the EIA were 93.3% and 95.5%, respectively. Fifteen serum specimens belonging to old-persons, pregnant women, blood donors, and patients with human leptospirosis, hepatitis, diabetes mellitus, tuberculosis and rheumatic fever gave false-positive results by Venereal Disease Research Laboratory and/or Rapid Plasma Reagin. The EIA can be used as alternative method for the serological confirmation of syphilis.

  8. Development of monoclonal antibody-based immunoassays for the analysis of bisphenol A in canned vegetables.

    Science.gov (United States)

    Moreno, María J; D'Arienzo, Pasquale; Manclús, Juan J; Montoya, Angel

    2011-01-01

    The aim of this work was the development of monoclonal antibodies (MAbs) and highly sensitive immunoassays (ELISAs) to bisphenol A (BPA), a well-known endocrine disruptor able to migrate from the internal coating of cans to food contained inside, particularly vegetables. To produce MAbs to BPA, four synthetic compounds were conjugated to proteins and used as immunizing haptens in mice. By applying hybridoma technology, several MAbs were produced and selected. These antibodies were characterized in the conjugate-coated and in the antibody-coated formats, using both homologous and heterologous conjugates. Three indirect ELISA based on the MAbs showing the highest affinity to BPA were selected. The limit of detection of the most sensitive ELISA was 0.22 nM (0.05 ng/mL), with an I₅₀ value of around 1 nM (0.23 ng/mL). An homologous ELISA based on the MAb BPAB-11 was applied to the simple, direct determination of BPA in the liquid portion of canned artichoke, peas, and sweet corn. Only sample dilution in an appropriate saline buffer was required to minimize matrix effects and to enter the ELISA working range. Recovery and precision of the method were evaluated by spiking the liquid portion of these cans with BPA at 20, 50, and 100 ng/mL. Coefficients of variation were below 20% in most cases. With regard to recovery, the analytical data obtained were also acceptable. This immunoassay has therefore proved its potential as a new tool for the rapid, sensitive and accurate determination of BPA in canned food.

  9. Vertical microreactor stack consist of poly-(tetrafluoroethylene) microfluidics for immunoassay

    International Nuclear Information System (INIS)

    Ukita, Yoshiaki; Kondo, Saki; Utsumi, Yuichi; Takeo, Masahiro; Negoro, Seiji; Kataoka, Chiwa

    2010-01-01

    This paper reports the first application of high-aspect ratio PTFE microstruscute, which fabricated by synchrotron radiation induced photo-evaporation process, to enzyme-linked immunosorvent assay. The advantages of PTFE microstructure for the development of lab-on-a-chip due to the extremely high-aspect ratio microstructure and chemical stability of PTFE is discussed. The results of immunoassay shows the successful detection of analyte (mouse IgG) with detection range with 0-100ng/ml. This result suggests the successful immobilization of antibody (anti-mouse IgG goat antibody) onto the x-ray exposed surface of PTFE microstructure and successful demonstration of antigen-antibody reaction in the PTFE high-aspect ratio microstructure. We also demonstrated the detection of polychlorinated biphenyl (PCB). As the result of demonstration, we successfully detected PCB with ranging analyte concentration of 0.1-10 ng/ml. (author)

  10. Comparative studies on the determination of alphafetoprotein by enzyme immunoassay and by radioimmunoassay

    International Nuclear Information System (INIS)

    Haller, G.; Linneke, P.; Voss, P.; Jeske, W.

    1987-01-01

    Alphafetoprotein (AFP) was determined in serum of pregnant women in the tenth till sixteenth week of pregnancy by means of two enzyme immunoassays (Enzymun-Test AFP, Boehringer Mannheim, FRG and AFP EIA 'Dessau' 1000, Research Institute for Vaccine Dessau, GDR) and a radioimmunoassay (Radioimmunoassay Kit, AFP-PR, CIS, France). Parallel determinations in sera of 438 patients, who had come to surveillance for the first consultation were estimated. A comparison between the methods showed a good correlation. (author)

  11. Nanobody Based Immunoassay for Human Soluble Epoxide Hydrolase Detection Using Polymeric Horseradish Peroxidase (PolyHRP) for Signal Enhancement: The Rediscovery of PolyHRP?

    Science.gov (United States)

    Li, Dongyang; Cui, Yongliang; Morisseau, Christophe; Gee, Shirley J; Bever, Candace S; Liu, Xiangjiang; Wu, Jian; Hammock, Bruce D; Ying, Yibin

    2017-06-06

    Soluble epoxide hydrolase (sEH) is a potential pharmacological target for treating hypertension, vascular inflammation, cancer, pain, and multiple cardiovascular related diseases. A variable domain of the heavy chain antibody (termed single domain antibody (sdAb), nanobody, or VHH) possesses the advantages of small size, high stability, ease of genetic manipulation, and ability for continuous manufacture, making such nanobody a superior choice as an immunoreagent. In this work, we developed an ultrasensitive nanobody based immunoassay for human sEH detection using polymeric horseradish peroxidase (PolyHRP) for signal enhancement. Llama nanobodies against human sEH were used as the detection antibody in sandwich enzyme linked immunosorbent assays (ELISA) with polyclonal anti-sEH as the capture antibody. A conventional sandwich ELISA using a horseradish peroxidase (HRP) labeled anti-hemeagglutinin (HA) tag as the tracer showed a marginal sensitivity (0.0015 optical density (OD)·mL/ng) and limit of detection (LOD) of 3.02 ng/mL. However, the introduction of the PolyHRP as the tracer demonstrated a 141-fold increase in the sensitivity (0.21 OD·mL/ng) and 57-fold decrease in LOD (0.05 ng/mL). Systematic comparison of three different tracers in four ELISA formats demonstrated the overwhelming advantage of PolyHRP as a label for nanobody based immunoassay. This enhanced sEH immunoassay was further evaluated in terms of selectivity against other epoxide hydrolases and detection of the target protein in human tissue homogenate samples. Comparison with an enzyme activity based assay and a Western blot for sEH detection reveals good correlation with the immunoassay. This work demonstrates increased competiveness of nanobodies for practical sEH protein detection utilizing PolyHRP. It is worthwhile to rediscover the promising potential of PolyHRP in nanobody and other affinity based methods after its low-profile existence for decades.

  12. Anti-idiotypic nanobody-alkaline phosphatase fusion proteins: Development of a one-step competitive enzyme immunoassay for fumonisin B{sub 1} detection in cereal

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Mei [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Xu, Yang, E-mail: xuyang@ncu.edu.cn [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Liu, Xing [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); College of Food Science and Technology, Hainan University, No. 58 Renmin Avenue, Haikou 570228 (China); Li, Yanping; He, Qinghua [Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Tu, Zhui [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Fu, Jinheng [Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Gee, Shirley J.; Hammock, Bruce D. [Department of Entomology and UCD Comprehensive Cancer Center, University of California, Davis, CA 95616 (United States)

    2016-06-14

    A rapid and sensitive one-step competitive enzyme immunoassay for the detection of FB{sub 1} was developed. The anti-idiotypic nanobody–alkaline phosphatase (Ab2β−Nb−AP) was validated by the AP enzyme activity and the properties of bounding to anti-FB1-mAb (3F11) through colorimetric and chemiluminescence analyses. The 50% inhibitory concentration and the detection limit (LOD) of colorimetric enzyme-linked immunosorbent assay (ELISA) for FB{sub 1} were 2.69 and 0.35 ng mL{sup −1}, respectively, with a linear range of 0.93–7.73 ng mL{sup −1}. The LOD of the chemiluminescence ELISA (CLIA) was 0.12 ng mL{sup −1}, and the IC{sub 50} was 0.89 ± 0.09 ng mL{sup −1} with a linear range of 0.29–2.68 ng mL{sup −1}. Compared with LC-MS/MS, the results of this assay indicated the reliability of the Ab2β−Nb−AP fusion protein based one-step competitive immunoassay for monitoring FB{sub 1} contamination in cereals. The Ab2β−Nb−AP fusion proteins have the potential to replace chemically-coupled probes in competitive enzyme immunoassay systems. - Highlights: • Ab2β−Nb−AP has the potential to replace chemically-coupled probes. • Ab2β−Nb−AP is homogeneous enzyme-labelled antigen can be prepared reproducibly. • We developed a green and rapid one-step competitive enzyme immunoassay. • The sensitivity of one-step CLIA was 9-folds higher than two-step ELISA.

  13. Development of an enzyme immunoassay for the antibiotic cefquinome and its application for residue determination in cow's milk after therapeutical mastitis treatment.

    Science.gov (United States)

    Thal, Johannes; Steffen, Monika; Meier, Bianca; Schneider, Elisabeth; Adriany, Ansgar; Usleber, Ewald

    2011-01-01

    The aim of this study was to develop and evaluate an enzyme immunoassay (EIA) for the cephalosporin antibiotic in milk, in combination with a new microbiological test system (brilliant black reduction test, BRT-P). Polyclonal antibodies against cefquinome were produced in rabbits, using cefquinome-keyhole limpet hemocyanine as the immunogen. These antibodies and a cefquinome-glucose oxidase conjugate were used in a competitive indirect EIA. The detection limit for cefquinome in milk was 1.5 ng ml(-1), recoveries were 80-128% at 4-40 ng ml(-1). Cross-reactivities with other cephalosporins/penicillins were all <1%. The EIA was used to determine cefquinome in incurred raw milk, the BRT-P (detection limit ≈ 20 ng ml(-1)) and a receptor assay (ßeta-s.t.a.r., detection limit ≈ 15 ng ml(-1)) were used in parallel. Five lactating cows, suffering from clinical mastitis, were treated with cefquinome by simultaneous intramammary and intramuscular injection. Cefquinome residues (maximum 10-27 μg ml(-1)) were most exclusively found in the udder quarter which was treated intramammary, residue levels in the other three quarters were low (<20 ng ml(-1)). Even in milk from intramammary-dosed quarters, residue levels fell below European Union maximum residue level (MRL, 20 μg kg(-1)) 2 days before the end of the withdrawal period. EIA, BRT-P, and ßeta-s.t.a.r. results showed acceptable agreement for milk samples, but the newly developed EIA is superior in aspects of sensitivity. In conclusion, this is the first one description of immunoassay and microbiological tests capable to determine cefquinome in milk at the MRL in incurred sample material.

  14. Development of an Ultrasensitive Immunoassay for Detecting Tartrazine

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-06-01

    Full Text Available We have developed an ultrasensitive indirect competitive enzyme-linked immunosorbent assay for the determination of tartrazine. Two carboxylated analogues of tartrazine with different spacer lengths, and one derivative from commercial tartrazine after a little chemical modification, were synthesized as haptens in order to produce antibodies specific to tartrazine. The effect of sulfonic acid groups on the hapten structure of tartrazine was also studied carefully for the first time. A most specific monoclonal antibody against tartrazine was created and exhibited an IC50 value of 0.105 ng/mL and a limit of detection of 0.014 ng/mL, with no cross-reactivity to other structurally-related pigments. The established immunoassay was applied to the determination of tartrazine in fortified samples of orange juice and in real positive samples of carbonated beverages.

  15. Iodoacetyl-functionalized pullulan: A supplemental enhancer for single-domain antibody-polyclonal antibody sandwich enzyme-linked immunosorbent assay for detection of survivin.

    Science.gov (United States)

    Matsushita, Takahiko; Arai, Hidenao; Koyama, Tetsuo; Hatano, Ken; Nemoto, Naoto; Matsuoka, Koji

    2017-11-01

    Survivin, an inhibitor of the apoptosis protein family, is a potent tumor marker for diagnosis and prognosis. The enzyme-linked immunosorbent assay (ELISA) is one of the methods that has been used for detection of survivin. However, ELISA has several disadvantages caused by the use of conventional antibodies, and we have therefore been trying to develop a novel ELISA system using camelid single-domain antibodies (VHHs) as advantageous replacements. Here we report a supplemental approach to improve the VHH-polyclonal antibody sandwich ELISA for survivin detection. Iodoacetyl-functionalized pullulan was synthesized, and its thiol reactivity was characterized by a model reaction with l-cysteine. The thiophilic pullulan was applied to an immunoassay asan additive upon coating of standard assay plates with an anti-survivin VHH fusion protein with C-terminal cysteine. The results showed that the mole ratio of the additive to VHH had a significant effect on the consequent response. Mole ratios of 0.07, 0.7, and 7 led to 90% lower, 15% higher, and 69% lower responses, respectively, than the response of a positive control in which no additive was used. The background levels observed in any additive conditions were as low as that of a negative control lacking both VHH and the additive. These results indicate the applicability of the thiol-reactive pullulan as a response enhancer to VHH-based ELISA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Micromotor-based lab-on-chip immunoassays

    Science.gov (United States)

    García, Miguel; Orozco, Jahir; Guix, Maria; Gao, Wei; Sattayasamitsathit, Sirilak; Escarpa, Alberto; Merkoçi, Arben; Wang, Joseph

    2013-01-01

    Here we describe the first example of using self-propelled antibody-functionalized synthetic catalytic microengines for capturing and transporting target proteins between the different reservoirs of a lab-on-a-chip (LOC) device. A new catalytic polymer/Ni/Pt microtube engine, containing carboxy moieties on its mixed poly(3,4-ethylenedioxythiophene) (PEDOT)/COOH-PEDOT polymeric outermost layer, is further functionalized with the antibody receptor to selectively recognize and capture the target protein. The new motor-based microchip immunoassay operations are carried out without any bulk fluid flow, replacing the common washing steps in antibody-based protein bioassays with the active transport of the captured protein throughout the different reservoirs, where each step of the immunoassay takes place. A first microchip format involving an `on-the-fly' double-antibody sandwich assay (DASA) is used for demonstrating the selective capture of the target protein, in the presence of excess of non-target proteins. A secondary antibody tagged with a polymeric-sphere tracer allows the direct visualization of the binding events. In a second approach the immuno-nanomotor captures and transports the microsphere-tagged antigen through a microchannel network. An anti-protein-A modified microengine is finally used to demonstrate the selective capture, transport and convenient label-free optical detection of a Staphylococcus aureus target bacteria (containing proteinA in its cell wall) in the presence of a large excess of non-target (Saccharomyces cerevisiae) cells. The resulting nanomotor-based microchip immunoassay offers considerable potential for diverse applications in clinical diagnostics, environmental and security monitoring fields.Here we describe the first example of using self-propelled antibody-functionalized synthetic catalytic microengines for capturing and transporting target proteins between the different reservoirs of a lab-on-a-chip (LOC) device. A new catalytic

  17. Isolation and functional effects of monoclonal antibodies binding to thymidylate synthase.

    Science.gov (United States)

    Jastreboff, M M; Todd, M B; Malech, H L; Bertino, J R

    1985-01-29

    Monoclonal antibodies against electrophoretically pure thymidylate synthase from HeLa cells have been produced. Antibodies (M-TS-4 and M-TS-9) from hybridoma clones were shown by enzyme-linked immunoassay to recognize thymidylate synthase from a variety of human cell lines, but they did not bind to thymidylate synthase from mouse cell lines. The strongest binding of antibodies was observed to enzyme from HeLa cells. These two monoclonal antibodies bind simultaneously to different antigenic sites on thymidylate synthase purified from HeLa cells, as reflected by a high additivity index and results of cross-linked radioimmunoassay. Both monoclonal antibodies inhibit the activity of thymidylate synthase from human cell lines. The strongest inhibition was observed with thymidylate synthase from HeLa cells. Monoclonal antibody M-TS-9 (IgM subclass) decreased the rate of binding of [3H]FdUMP to thymidylate synthase in the presence of 5,10-methylenetetrahydrofolate while M-TS-4 (IgG1) did not change the rate of ternary complex formation. These data indicate that the antibodies recognize different epitopes on the enzyme molecule.

  18. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  19. Catch and measure-mass spectrometry-based immunoassays in biomarker research.

    Science.gov (United States)

    Weiß, Frederik; van den Berg, Bart H J; Planatscher, Hannes; Pynn, Christopher J; Joos, Thomas O; Poetz, Oliver

    2014-05-01

    Mass spectrometry-based (MS) methods are effective tools for discovering protein biomarker candidates that can differentiate between physiological and pathophysiological states. Promising candidates are validated in studies comprising large patient cohorts. Here, targeted protein analytics are used to increase sample throughput. Methods involving antibodies, such as sandwich immunoassays or Western blots, are commonly applied at this stage. Highly-specific and sensitive mass spectrometry-based immunoassays that have been established in recent years offer a suitable alternative to sandwich immunoassays for quantifying proteins. Mass Spectrometric ImmunoAssays (MSIA) and Stable Isotope Standards and Capture by Anti-Peptide Antibodies (SISCAPA/iMALDI) are two prominent types of MS-based immunoassays in which the capture is done either at the protein or the peptide level. We present an overview of these emerging types of immunoassays and discuss their suitability for the discovery and validation of protein biomarkers. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge. © 2013.

  20. Pemanfaatan Antibodi Monoklonal dalam Immunoassay untuk Deteksi Baculovirus oryctes

    Directory of Open Access Journals (Sweden)

    Susamto Somowiyarjo

    2000-12-01

    Full Text Available The application of non-precoated Indirect Enzyme-Linked Immunosorbent Assay (ELISA and Dot Immunobinding Assay (DIBA employing monoclonal antibodies (MCA against Yogyakarta isolate of Baculovirus oryctes Huger. was described. The MCA-Bv-4 having subclass of IgG2a and titer in vitro of 10^4 - 10^5 proved to be useful antibody for virus detection. The great potential of I-ELISA using MCA-Bv-4 has been it's specificity being able to discriminate between healthy an virus-infected coconut beetle (Oryctes rhinoceros L.. The assay could also differentiate between B. oryctes and Monodon baculovirus, the pathogen of shrimp disease. The best tissue for preparing virus antigen from crude extract was found to be the midgut of the beetle. Head, thorax, abdomen and tibia were not suitable for preparing the test antigen. The crude extract of beetle showed high endogenous enzyme activity to the substrate of DIBA, which precluded the detection of B. oryctes using DIBA. The MCA-Bv-4 could be used to improve the monitoring of the virus to support the program of biological control of coconut beetle using B. oryctes.

  1. Immunoassay of serum polypeptide hormones by using 125I-labelled anti(-immunoglobulin G) antibodies.

    Science.gov (United States)

    Beck, P; Nicholas, H

    1975-03-01

    1. A technique for indirectly labelling antibodies to polypeptide hormones, by combining them with radioactively labelled anti-(immunoglobulin G) is described. (a) 125I-labelled anti-(rabbit immunoglobulin G) and anti-(guinea-pig immunoglobulin G) antibodies with high specific radioactivity were prepared after purification of the antibodies on immunoadsorbents containing the respective antigens. (b) Rabbit immunoglobulin G antibodies to human growth hormone, porcine glucagon and guinea-pig immunoglobulin G antibodies to bovine insulin and bovine parathyroid hormone were combined with immunoadsorbents containing the respective polypeptide hormone antigen. (c) The immunoglobulin G antibodies to the polypeptide hormones were reacted with 125-I-labelled anti-(immunoglobulin G) antibodies directed against the appropriate species of immunoglobulin G,and the anti-hormone antibodies were combined with the hormone-containing immunoadsorbent. (d) 125I-labelled anti-(immunoglobulin G) antibodies and anti-hormone antibodies were simultaneously eluted from the hormone-containing immunoadsorbent by dilute HCl, pH 2.0. After elution the anti-(immunoglobulin G) antibodies and antihormone antibodies were allowed to recombine at pH 8.0 and 4 degrees C. 2. The resultant immunoglobulin G-anti-immunoglobulin G complex was used in immunoradiometric (labelled antibody) and two-site assays of the respective polypeptide hormone. 3. By using these immunoassays, concentrations down to 90pg of human growth hormone/ml, 100 pg of bovine insulin/ml, 80 pg of bovine parathyroid hormone/ml and 150 pg of glucagon/ml were readily detected. Assays of human plasma for growth hormone and insulin by these methods showed good agreement with results obtained by using a directly 125I-labelled anti-hormone antibody in an immunoradiometric assay of human growth hormone or by radioimmunoassay of human insulin. 4. The method described allows immunoradiometric or two-site assays to be performed starting with as

  2. Detection of virus-specific intrathecally synthesised immunoglobulin G with a fully automated enzyme immunoassay system

    Directory of Open Access Journals (Sweden)

    Weissbrich Benedikt

    2007-05-01

    Full Text Available Abstract Background The determination of virus-specific immunoglobulin G (IgG antibodies in cerebrospinal fluid (CSF is useful for the diagnosis of virus associated diseases of the central nervous system (CNS and for the detection of a polyspecific intrathecal immune response in patients with multiple sclerosis. Quantification of virus-specific IgG in the CSF is frequently performed by calculation of a virus-specific antibody index (AI. Determination of the AI is a demanding and labour-intensive technique and therefore automation is desirable. We evaluated the precision and the diagnostic value of a fully automated enzyme immunoassay for the detection of virus-specific IgG in serum and CSF using the analyser BEP2000 (Dade Behring. Methods The AI for measles, rubella, varicella-zoster, and herpes simplex virus IgG was determined from pairs of serum and CSF samples of patients with viral CNS infections, multiple sclerosis and of control patients. CSF and serum samples were tested simultaneously with reference to a standard curve. Starting dilutions were 1:6 and 1:36 for CSF and 1:1386 and 1:8316 for serum samples. Results The interassay coefficient of variation was below 10% for all parameters tested. There was good agreement between AIs obtained with the BEP2000 and AIs derived from the semi-automated reference method. Conclusion Determination of virus-specific IgG in serum-CSF-pairs for calculation of AI has been successfully automated on the BEP2000. Current limitations of the assay layout imposed by the analyser software should be solved in future versions to offer more convenience in comparison to manual or semi-automated methods.

  3. NiCoBP-doped carbon nanotube hybrid: A novel oxidase mimetic system for highly efficient electrochemical immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bing; He, Yu; Liu, Bingqian; Tang, Dianping, E-mail: dianping.tang@fzu.edu.cn

    2014-12-03

    Highlights: • We report a new oxidase mimetic system for highly efficient electrochemical immunoassay. • NiCoBP-doped carbon nanotube hybrids were used as the nanocatalysts. • NiCoBP-doped carbon nanotube hybrids were used as the mimic oxidase. - Abstract: NiCoBP-doped multi-walled carbon nanotube (NiCoBP–MWCNT) was first synthesized by using induced electroless-plating method and functionalized with the biomolecules for highly efficient electrochemical immunoassay of prostate-specific antigen (PSA, used as a model analyte). We discovered that the as-synthesized NiCoBP–MWCNT had the ability to catalyze the glucose oxidization with a stable and well-defined redox peak. The catalytic current increased with the increment of the immobilized NiCoBP–MWCNT on the electrode. Transmission electron microscope (TEM) and energy dispersive X-ray spectrometry (EDX) were employed to characterize the as-prepared NiCoBP–MWCNT. Using the NiCoBP–MWCNT-conjugated anti-PSA antibody as the signal-transduction tag, a new enzyme-free electrochemical immunoassay protocol could be designed for the detection of target PSA on the capture antibody-functionalized immunosensing interface. Experimental results revealed that the designed immunoassay system could exhibit good electrochemical responses toward target PSA, and allowed the detection of PSA at a concentration as low as 0.035 ng mL{sup −1}. More importantly, the NiCoBP-MWCNT-based oxidase mimetic system could be further extended for the monitoring of other low-abundance proteins or disease-related biomarkers by tuning the target antibody.

  4. Immunoassay separation technique

    International Nuclear Information System (INIS)

    1977-01-01

    A method for effecting the immunoassay of a multiplicity of samples, each possibly containing an antigen or an antibody to be assayed, is discussed. Each sample is incubated with a solution containing a detectable antigen or antibody to form a multiplicity of mixtures, each mixture containing as components antigen-antibody, non-complexed antigen and non-complexed antibody. At least one of the components of the said mixture is separated by adsorption. There after, quantity of detectable antigen or antibody is detected in one of the non-adsorbed portions of the mixture. An improvement, compared to other techniques, is the continuous and sequential separation of at least one component, which is intended to be separated from each said multiplicity of mixtures

  5. Evaluation of automated enzyme immunoassays for five anticonvulsants and theophylline adapted to a centrifugal analyzer.

    Science.gov (United States)

    Urquhart, N; Godolphin, W; Campbell, D J

    1979-05-01

    We report a clinical evaluation of the enzyme immunoassay (EMIT) performed with the GEMSAEC centrifugal analyzer as compared to gas-liquid and liquid chromatography for anticonvulsant drugs and theophylline, respectively. A good correlation was obtained for all drugs, although some difficulties were experienced with one lot of reagent for ethosuximide. The analyzer has an economic advantage if many samples are being analyzed for few drugs in each sample.

  6. Evaluation of two automated enzyme-immunoassays for detection of thermophilic campylobacters in faecal samples from cattle and swine

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Nielsen, E.M.; Stryhn, H.

    1999-01-01

    We evaluated the performance of two enzyme-immunoassays (EIA) for the detection of naturally occurring, thermophilic Campylobacter spp. found in faecal samples from cattle (n = 21 and n = 26) and swine (n = 43) relative to the standard culture method, and also assuming that none of the tests...

  7. Evaluation and comparison of radio-, fluorescence, and enzyme-linked immunoassays for serum thyroxine

    International Nuclear Information System (INIS)

    Kaplan, L.A.; Gau, N.; Fearn, J.; Steain, E.A.; Chen, I.W.; Maxon, H.; Volle, C.

    1981-01-01

    We have compared three analytical systems for the measurement of serum thyroxine: enzyme-linked immunoassay (EIA), fluorescent immunoassay (FIA) and a radioimmunoassay (RIA). These were evaluated with respect to their precision, accuracy, analytical sensitivity and sample throughput. The RIA is more sensitive than the EIA (10 μg/L vs. 35 μg/L). Both systems have excellent precision (X=86 μg/L, C.V.sub(RIA)=C.V.sub(EIA)=4.6 percent). Both the EIA and RIA demonstrate good accuracy with recovery of between 97-98 percent of added thyroxine. The FIA has an apparent sensitiviity between that of the RIA and EIA (25 μg/L), but a precision consistently lower than the other two systems (C.V. =7.4 percent, X=86 μg/L). Patients' results by RIA compared well with those from EIA (r=0.91,P 0.05). Although not fully automated, the EIA performed on the Abbott ABA-100 analyzer has a sample throughput equal to the automated RIA system (Micromedic, Concept 4)

  8. A conventional chemical reaction for use in an unconventional assay: A colorimetric immunoassay for aflatoxin B1 by using enzyme-responsive just-in-time generation of a MnO2 based nanocatalyst.

    Science.gov (United States)

    Lai, Wenqiang; Zeng, Qiao; Tang, Juan; Zhang, Maosheng; Tang, Dianping

    2018-01-10

    The authors describe a colorimetric immunoassay for the model nalyte aflatoxin B 1 (AFB 1 ). It is based on the just-in-time generation of an MnO 2 nanocatalyst. Unlike previously developed immunoassay, the chromogenic reaction relies on the just-in-time formation of an oxidase mimic without the aid of the substrate. Potassium permanganate (KMnO 4 ) is converted into manganese dioxide (MnO 2 ) which acts as an oxidase mimic that catalyzes the oxidation 3,3',5,5'-tetramethylbenzidine (TMB) by oxygen to give a blue colored product. In the presence of ascorbic acid (AA), KMnO 4 is reduced to Mn(II) ions. This results in a decrease in the amount of MnO 2 nanocatalyst. Hence, the oxidation of TMB does not take place. By adding ascorbate oxidase, AA is converted into dehydroascorbic acid which cannot reduce KMnO 4 . Based on these observations, a colorimetric competitive enzyme immunoassay was developed where ascorbate oxidase and gold nanoparticle-labeled antibody against AFB 1 and magnetic beads carrying bovine serum albumin conjugated to AFB 1 are used for the determination of AFB 1 . In presence of AFB 1 , it will compete with the BSA-conjugated AFB 1 (on the magnetic beads) for the labeled antibody against AFB 1 on the gold nanoparticles. This makes the amount of ascorbate oxidase/anti-AFB 1 antibody-labeled gold nanoparticles, which conjugated on magnetic beads, reduce, and resulted in an increase of ascorbic acid. Under optimal conditions, the absorbance (measured at 652 nm) decreases with increasing AFB 1 concentrations in the range from 0.1 to 100 ng mL -1 , with a 0.1 ng mL -1 detection limit (at the 3S blank level). The accuracy of the assay was validated by analyzing spiked peanut samples. The results matched well with those obtained with a commercial ELISA kit. Conceivably, the method is not limited to aflatoxins but has a wide scope in that it may be applied to many other analytes for which respective antibodies are available. Graphical abstract

  9. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    Science.gov (United States)

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  10. Synthesis of an oxytetracyline-tolidin-BSA immunogen and antibodies production of anti-oxytetracyline developed for oxytetracyline residue detection with enzyme-linked immunosorbent assays technique

    Directory of Open Access Journals (Sweden)

    Widiastuti R

    2013-06-01

    Full Text Available An oxytetracycline-tolidin-bovine serum albumin (OTC-tolidin-BSA-conjugate was synthezed as immunogen for producing specific antibodies in immunized rabbits that would be used as reagent for development of OTC residue detection with enzym-linked immunoassays technique. The immunogen was prepared through diazotization tolidin and subsequently reacted with OTC. The red purple immunogen of OTC-tolidin-BSA absorbed at wave lengths of 277 nm and 488 nm under UV screening absorbances and confirmation with the high performance liquid chromatography (HPLC showed the absence of peak at retention time of 3.46 minutes. Characaterized result with SDS-PAGE showed the molecular weight of the OTC-tolidin-BSA at 69.79 kDA. Subsequently, the immunogen was immunized into New Zealand rabbits in order to produce the polyclonal antibodies. The antibodies were purified using a protein A sepharose column. The OD optimum responses of 0.92 to 1.20 were obtained from the second fractionation at dilution of 1/1000 by titrating the antibodies and OTC-tolidin-BSA coating antigen at concentration of 10 µg/mL on several bleeding times.

  11. Pregnancy does not affect HIV incidence test results obtained using the BED capture enzyme immunoassay or an antibody avidity assay.

    Directory of Open Access Journals (Sweden)

    Oliver Laeyendecker

    2010-10-01

    Full Text Available Accurate incidence estimates are needed for surveillance of the HIV epidemic. HIV surveillance occurs at maternal-child health clinics, but it is not known if pregnancy affects HIV incidence testing.We used the BED capture immunoassay (BED and an antibody avidity assay to test longitudinal samples from 51 HIV-infected Ugandan women infected with subtype A, C, D and intersubtype recombinant HIV who were enrolled in the HIVNET 012 trial (37 baseline samples collected near the time of delivery and 135 follow-up samples collected 3, 4 or 5 years later. Nineteen of 51 women were also pregnant at the time of one or more of the follow-up visits. The BED assay was performed according to the manufacturer's instructions. The avidity assay was performed using a Genetic Systems HIV-1/HIV-2 + O EIA using 0.1M diethylamine as the chaotropic agent.During the HIVNET 012 follow-up study, there was no difference in normalized optical density values (OD-n obtained with the BED assay or in the avidity test results (% when women were pregnant (n = 20 results compared to those obtained when women were not pregnant (n = 115; for BED: p = 0.9, generalized estimating equations model; for avidity: p = 0.7, Wilcoxon rank sum. In addition, BED and avidity results were almost exactly the same in longitudinal samples from the 18 women who were pregnant at only one study visit during the follow-up study (p = 0.6, paired t-test.These results from 51 Ugandan women suggest that any changes in the antibody response to HIV infection that occur during pregnancy are not sufficient to alter results obtained with the BED and avidity assays. Confirmation with larger studies and with other HIV subtypes is needed.

  12. Development of an efficient signal amplification strategy for label-free enzyme immunoassay using two site-specific biotinylated recombinant proteins

    International Nuclear Information System (INIS)

    Tang, Jin-Bao; Tang, Ying; Yang, Hong-Ming

    2015-01-01

    Highlights: • An efficient signal amplification strategy for label-free EIA is proposed. • Divalent biotinylated AP and monovalent biotinylated ZZ were prepared via Avitag–BirA system. • The above site-specific biotinylated fusion proteins form complex via SA–biotin interaction. • The mechanism relies on the ZZ–Avi-B/SA/AP–(Avi-B) 2 complex. • The analytical signals are enhanced (32-fold) by the proposed strategy. - Abstract: Constructing a recombinant protein between a reporter enzyme and a detector protein to produce a homogeneous immunological reagent is advantageous over random chemical conjugation. However, the approach hardly recombines multiple enzymes in a difunctional fusion protein, which results in insufficient amplification of the enzymatic signal, thereby limiting its application in further enhancement of analytical signal. In this study, two site-specific biotinylated recombinant proteins, namely, divalent biotinylated alkaline phosphatase (AP) and monovalent biotinylated ZZ domain, were produced by employing the Avitag–BirA system. Through the high streptavidin (SA)–biotin interaction, the divalent biotinylated APs were clustered in the SA–biotin complex and then incorporated with the biotinylated ZZ. This incorporation results in the formation of a functional macromolecule that involves numerous APs, thereby enhancing the enzymatic signal, and in the production of several ZZ molecules for the interaction with immunoglobulin G (IgG) antibody. The advantage of this signal amplification strategy is demonstrated through ELISA, in which the analytical signal was substantially enhanced, with a 32-fold increase in the detection sensitivity compared with the ZZ–AP fusion protein approach. The proposed immunoassay without chemical modification can be an alternative strategy to enhance the analytical signals in various applications involving immunosensors and diagnostic chips, given that the label-free IgG antibody is suitable for

  13. Development of an efficient signal amplification strategy for label-free enzyme immunoassay using two site-specific biotinylated recombinant proteins

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Jin-Bao [School of Pharmacy, Weifang Medical University, Weifang 261053 (China); Tang, Ying [Affiliated Hospital of Weifang Medical University, Weifang 261041 (China); Yang, Hong-Ming, E-mail: yanghongming2006@sohu.com [School of Pharmacy, Weifang Medical University, Weifang 261053 (China)

    2015-02-15

    Highlights: • An efficient signal amplification strategy for label-free EIA is proposed. • Divalent biotinylated AP and monovalent biotinylated ZZ were prepared via Avitag–BirA system. • The above site-specific biotinylated fusion proteins form complex via SA–biotin interaction. • The mechanism relies on the ZZ–Avi-B/SA/AP–(Avi-B){sub 2} complex. • The analytical signals are enhanced (32-fold) by the proposed strategy. - Abstract: Constructing a recombinant protein between a reporter enzyme and a detector protein to produce a homogeneous immunological reagent is advantageous over random chemical conjugation. However, the approach hardly recombines multiple enzymes in a difunctional fusion protein, which results in insufficient amplification of the enzymatic signal, thereby limiting its application in further enhancement of analytical signal. In this study, two site-specific biotinylated recombinant proteins, namely, divalent biotinylated alkaline phosphatase (AP) and monovalent biotinylated ZZ domain, were produced by employing the Avitag–BirA system. Through the high streptavidin (SA)–biotin interaction, the divalent biotinylated APs were clustered in the SA–biotin complex and then incorporated with the biotinylated ZZ. This incorporation results in the formation of a functional macromolecule that involves numerous APs, thereby enhancing the enzymatic signal, and in the production of several ZZ molecules for the interaction with immunoglobulin G (IgG) antibody. The advantage of this signal amplification strategy is demonstrated through ELISA, in which the analytical signal was substantially enhanced, with a 32-fold increase in the detection sensitivity compared with the ZZ–AP fusion protein approach. The proposed immunoassay without chemical modification can be an alternative strategy to enhance the analytical signals in various applications involving immunosensors and diagnostic chips, given that the label-free IgG antibody is suitable

  14. Self-paired monoclonal antibody lateral flow immunoassay strip for rapid detection of Acidovorax avenae subsp. citrulli.

    Science.gov (United States)

    Zeng, Haijuan; Guo, Wenbo; Liang, Beibei; Li, Jianwu; Zhai, Xuzhao; Song, Chunmei; Zhao, Wenjun; Fan, Enguo; Liu, Qing

    2016-09-01

    We screened a highly specific monoclonal antibody (McAb), named 6D, against Acidovorax avenae subsp. citrulli (Aac). Single McAb 6D was used as both nanogold-labeled antibody and test antibody to develop a single self-paired colloidal gold immunochromatographic test strip (Sa-GICS). The detection limit achieved using the Sa-GICS approach was 10(5) CFU/mL, with a result that can be observed by the naked eye within 10 min. Moreover, Sa-GICS can detect eight strains of Aac and display no cross-reactions with other pathogenic plant microorganisms. Artificial contamination experiments demonstrated that Sa-GICS would not be affected by impurities in the leaves or stems of the plants and were consistent with the PCR results. This is the first report on the development of a colloidal gold immunoassay strip with self-paired single McAb for the rapid detection of Aac. Graphical Abstract Schematic representation of the test strip.

  15. New antibody and immunoassay pretreatment strategy to screen polychlorinated biphenyls in Korean transformer oil.

    Science.gov (United States)

    Terakado, Shingo; Ohmura, Naoya; Park, Seok-Un; Lee, Seung-Min; Glass, Thomas R

    2013-01-01

    Development and modifications are described that expand the application of an immunoassay from the detection of Kanechlors (Japanese technical PCBs mixtures) to the detection of Aroclors (U. S. technical PCB mixtures, used in Korea) in contaminated Korean transformer oil. The first necessary modification was the development of a new antibody with a reactivity profile favorable for Aroclors. The second modification was the addition of a second column to the solid-phase extraction method to reduce assay interference caused by the Korean oil matrix. The matrix interference is suspected to be caused by the presence of synthetic oils (or similar materials) present as contaminants. The modified assay was validated by comparison to high-resolution gas chromatography/high-resolution mass spectrometry analysis, and was shown to be tolerant of up to 10% of several common synthetic insulating oils. Finally the screening performance of the modified assay was evaluated using 500 used transformer oil samples of Korean origin, and was shown to have good performance in terms of false positive and false negative rates. This report provides evidence for the first establishment of immunoassay screening for Aroclor based PCB contamination in Korean transformer oil.

  16. Antiphospholipid antibody: laboratory, pathogenesis and clinical manifestations

    Directory of Open Access Journals (Sweden)

    T. Ziglioli

    2011-06-01

    Full Text Available Antiphospholipid antibodies (aPL represent a heterogeneous group of antibodies that recognize various antigenic targets including beta2 glycoprotein I (β2GPI, prothrombin (PT, activated protein C, tissue plasminogen activator, plasmin and annexin A2. The most commonly used tests to detect aPL are: lupus anticoagulant (LAC, a functional coagulation assay, anticardiolipin antibody (aCL and anti-β2GPI antibody (anti-β2GPI, which are enzyme-linked immunoassay (ELISA. Clinically aPL are associated with thrombosis and/or with pregnancy morbidity. Apparently aPL alone are unable to induce thrombotic manifestations, but they increase the risk of vascular events that can occur in the presence of another thrombophilic condition; on the other hand obstetrical manifestations were shown to be associated not only to thrombosis but mainly to a direct antibody effect on the trophoblast.

  17. Compact quantum dot-antibody conjugates for FRET immunoassays with subnanomolar detection limits

    Science.gov (United States)

    Mattera, Lucia; Bhuckory, Shashi; Wegner, K. David; Qiu, Xue; Agnese, Fabio; Lincheneau, Christophe; Senden, Tim; Djurado, David; Charbonnière, Loïc J.; Hildebrandt, Niko; Reiss, Peter

    2016-05-01

    A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post-functionalization with a heterobifunctional crosslinker, containing a lipoic acid group and a maleimide function, enabled the subsequent coupling to sulfhydryl groups of proteins. This was demonstrated by QD conjugation with fragmented antibodies (F(ab)). The obtained F(ab)-QD conjugates range among the smallest antibody-functionalized nanoprobes ever reported, with a hydrodynamic diameter coating for FRET could be demonstrated by an 6.2 and 2.5 fold improvement of the limit of detection (LOD) for PSA compared to commercially available hydrophilic QDs emitting at 605 and 705 nm, respectively. While the commercial QDs contain identical inorganic cores responsible for their fluorescence, they are coated with a comparably thick amphiphilic polymer layer leading to much larger hydrodynamic diameters (>26 nm without biomolecules). The LODs of 0.8 and 3.7 ng mL-1 obtained in 50 μL serum samples are below the clinical cut-off level of PSA (4 ng mL-1) and demonstrate their direct applicability in clinical diagnostics.A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post

  18. Improved porous silicon (P-Si) microarray based PSA (prostate specific antigen) immunoassay by optimized surface density of the capture antibody

    Science.gov (United States)

    Lee, SangWook; Kim, Soyoun; Malm, Johan; Jeong, Ok Chan; Lilja, Hans; Laurell, Thomas

    2014-01-01

    Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA - prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5ngmL−1, 80pgmL−1, and 800fgmL−1 when arraying the PSA antibody, H117 at the concentration 15µgmL−1, 35µgmL−1 and 154µgmL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800fgmL−1 to 500ngmL−1. The microarray showed a LOD of 800fgmL−1 and a dynamic range of 800 fgmL−1 to 80ngmL−1 in serum spiked samples. PMID:24016590

  19. Routinely used immunoassays do not detect circulating anti-GBM antibodies against native NC1 hexamer and EA epitope of the α3 chain of type IV collagen.

    Science.gov (United States)

    Clavarino, Giovanna; Gauthier, Arnaud; Hellmark, Thomas; Carron, Pierre-Louis; Giovannini, Diane; Colliard, Sophie; Dragon-Durey, Marie-Agnès; Segelmark, Mårten; Cesbron, Jean-Yves; Dumestre-Pérard, Chantal

    2018-04-12

    Detection of circulating anti-GBM antibodies has a key role for the diagnosis of Goodpasture syndrome but immunoassays using purified or recombinant alpha3(IV)NC1 as antigen do not recognize all anti-GBM antibodies. We show that anti-GBM antibodies directed against epitopes in their native conformation or cryptic epitopes are detected by indirect immunofluorescence. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Influence of gamma radiation on antibodies fixation on polystyrene. Application to ELISA enzyme immunoassay

    International Nuclear Information System (INIS)

    Esterlin, S.

    1986-01-01

    This thesis is divided into two parts: the first part includes a description of the ELISA test, a comparative analysis of the main supports (polystyrene microtitration trays) used for this technique and an evaluation of gamma radiation effects on the quality of the supports. The study was carried out with the following antigens: Spiroplasma citri R8A2, a tymovirus and Tristeza virus. The second part dealt with the effects of gamma radiations on antibodies and antibody-support system (interaction immobilized immunoglobulins-plastic support) [fr

  1. Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Yang Zhanjun [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); College of Chemistry and Engineering, Yangzhou University, 88 South University Avenue, Yangzhou 225002 (China); Zong Chen [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Ju Huangxian, E-mail: hxju@nju.edu.cn [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Yan Feng, E-mail: yanfeng2007@sohu.com [Jiangsu Institute of Cancer Prevention and Cure, Nanjing 210009 (China)

    2011-11-07

    Highlights: {yields} A novel capillary immune microreactor was proposed for highly efficient flow-through chemiluminescent immunoassay. {yields} The microreactor was prepared by functionalizing capillary inner wall with streptavidin for capture of biotinylated antibody. {yields} The proposed immunoassay method showed wide dynamic range, good reproducibility, stability and practicality. {yields} The microreactor was low-cost and disposable, and possessed several advantages over the conventional immunoreactors. - Abstract: A streptavidin functionalized capillary immune microreactor was designed for highly efficient flow-through chemiluminescent (CL) immunoassay. The functionalized capillary could be used as both a support for highly efficient immobilization of antibody and a flow cell for flow-through immunoassay. The functionalized inner wall and the capture process were characterized using scanning electron microscopy. Compared to conventional packed tube or thin-layer cell immunoreactor, the proposed microreactor showed remarkable properties such as lower cost, simpler fabrication, better practicality and wider dynamic range for fast CL immunoassay with good reproducibility and stability. Using {alpha}-fetoprotein as model analyte, the highly efficient CL flow-through immunoassay system showed a linear range of 3 orders of magnitude from 0.5 to 200 ng mL{sup -1} and a low detection limit of 0.1 ng mL{sup -1}. The capillary immune microreactor could make up the shortcoming of conventional CL immunoreactors and provided a promising alternative for highly efficient flow-injection immunoassay.

  2. Good performance of an immunoassay based method for nevirapine measurements in human breast milk

    DEFF Research Database (Denmark)

    Salado-Rasmussen, Kirsten; Theilgaard, Zahra Persson; Chiduo, Mercy

    2011-01-01

    from HIV-uninfected women. Clinical samples from HIV-infected women receiving a single-dose of nevirapine were analyzed. Results: Precision and accuracy were evaluated with two concentrations of quality control materials analyzed in three replicates on four different days and was......, requires complicated extraction techniques. The ARK method employs an immunoassay technology and requires a small sample volume (40 μL) and no pre-treatment of the samples. Methods: Commercial enzyme and antibody were used and calibration standards and quality controls were prepared from pooled breast milk...

  3. Materials for Microfluidic Immunoassays: A Review.

    Science.gov (United States)

    Mou, Lei; Jiang, Xingyu

    2017-08-01

    Conventional immunoassays suffer from at least one of these following limitations: long processing time, high costs, poor user-friendliness, technical complexity, poor sensitivity and specificity. Microfluidics, a technology characterized by the engineered manipulation of fluids in channels with characteristic lengthscale of tens of micrometers, has shown considerable promise for improving immunoassays that could overcome these limitations in medical diagnostics and biology research. The combination of microfluidics and immunoassay can detect biomarkers with faster assay time, reduced volumes of reagents, lower power requirements, and higher levels of integration and automation compared to traditional approaches. This review focuses on the materials-related aspects of the recent advances in microfluidics-based immunoassays for point-of-care (POC) diagnostics of biomarkers. We compare the materials for microfluidic chips fabrication in five aspects: fabrication, integration, function, modification and cost, and describe their advantages and drawbacks. In addition, we review materials for modifying antibodies to improve the performance of the reaction of immunoassay. We also review the state of the art in microfluidic immunoassays POC platforms, from the laboratory to routine clinical practice, and also commercial products in the market. Finally, we discuss the current challenges and future developments in microfluidic immunoassays. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Nanobody-based enzyme immunoassay for ochratoxin A in cereal with high resistance to matrix interference.

    Science.gov (United States)

    Liu, Xing; Tang, Zongwen; Duan, Zhenhua; He, Zhenyun; Shu, Mei; Wang, Xianxian; Gee, Shirley J; Hammock, Bruce D; Xu, Yang

    2017-03-01

    A sensitive indirect competitive nanobody-based enzyme linked immunosorbent assay (Nb-ELISA) for ochratoxin A (OTA) with high resistance to cereal matrix interference was developed. Nanobodies against OTA (Nb15, Nb28, Nb32, Nb36) were expressed in E. coli cells and their thermal stabilities were compared with that of an OTA-specific monoclonal antibody 6H8. All nanobodies could still retain their antigen-binding activity after exposure to temperature 95°C for 5min or to 90°C for 75min. Nb28 that exhibited the highest sensitivity in ELISA was selected for further research. An indirect competitive ELISA based on Nb28 was developed for OTA, with an IC 50 of 0.64ng/mL and a linear range (IC 20 -IC 80 ) of 0.27-1.47ng/mL. Cereal samples were analyzed following a 2.5 fold dilution of sample extracts, showing the good resistance to matrix interference of the Nb-ELSIA. The recovery of spiked cereal samples (rice, oats, barley) ranged from 80% to 105% and the Nb-ELISA results of OTA content in naturally contamined samples were in good agreement with those determined by a commercial ELISA kit. The results indicated the reliablity of nanobody as a promising immunoassay reagent for detection of mycotoxins in food matrix and its potential in biosensor development. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Highly sensitive immunoassay based on E. coli with autodisplayed Z-domain

    International Nuclear Information System (INIS)

    Jose, Joachim; Park, Min; Pyun, Jae-Chul

    2010-01-01

    The Z-domain of protein A has been known to bind specifically to the F c region of antibodies (IgGs). In this work, the Z-domain of protein A was expressed on the outer membrane of Escherichia coli by using 'Autodisplay' technology as a fusion protein of autotransport domain. The E. coli with autodisplayed Z-domain was applied to the sandwich-type immunoassay as a solid-support of detection-antibodies against a target analyte. For the feasibility demonstration of the E. coli based immunoassay, C-reactive protein (CRP) assay was carried out by using E. coli with autodisplayed Z-domain. The limit of detection (LOD) and binding capacity of the E. coli based immunoassay were estimated to be far more sensitive than the conventional ELISA. Such a far higher sensitivity of E. coli based immunoassay than conventional ELISA was explained by the orientation control of immobilized antibodies and the mobility of E. coli in assay matrix. From the test results of 45 rheumatoid arthritis (RA) patients' serum and 15 healthy samples, a cut-off value was established to have optimal sensitivity and selectivity values for RA. The CRP test result of each individual sample was compared with ELISA which is the reference method for RA diagnosis. From this work, the E. coli with Z-domain was proved to be feasible for the medical diagnosis based on sandwich-type immunoassay.

  6. A fast universal immobilization of immunoglobulin G at 4 °C for the development of array-based immunoassays.

    Directory of Open Access Journals (Sweden)

    Shu-Lin Guo

    Full Text Available To maintain the antibody activity and enhance performance of array-based immunoassays, protein G was used to allow a shorter duration of immunoglobulin G immobilization at 4 °C, with the antibody placed in the appropriate orientation. The multiplexed detection of six pain-related message molecules (PRMMs was used as examples for the development of array-based immunoassays: substance P, calcitonin gene-related peptide, nerve growth factor, brain-derived neurotrophic factor, tumor necrosis factor-α, and β-endorphin. Protein G- and non-protein G-coated slides were tested. Compared to non-protein G immunoassays, protein G shortened the antibody immobilization time at 4 °C from overnight to 2 hours. Only protein G-facilitated immunoassays succeeded in simultaneously detecting all six PRMMs with high specificity. Dose-response curves showed that the limits of detection of the protein G-multiplexed immunoassays for the PRMMs was approximately 164, 167, 120, 60, 80, and 92 pg/ml, respectively. Thus, protein G effectively shortens the duration of antibody immobilization at 4 °C, allowing the use of sensitive array-based immunoassays for the simultaneous detection of PRMMs.

  7. Fluorescence immunoassay for detecting periodontal bacterial pathogens in plaque.

    OpenAIRE

    Wolff, L F; Anderson, L; Sandberg, G P; Aeppli, D M; Shelburne, C E

    1991-01-01

    A particle concentration fluorescence immunoassay has been modified into a bacterial concentration fluorescence immunoassay (BCFIA) to rapidly detect periodontopathic bacteria in human plaque samples. The BCFIA utilizes fluorescently tagged monoclonal antibodies (MAbs) directed against the lipopolysaccharide of selected gram-negative plaque bacteria. Microorganisms closely associated with periodontal disease that can be identified in plaque with the BCFIA include Porphyromonas gingivalis, Bac...

  8. Automated thermometric enzyme immunoassay of human proinsulin produced by Escherichia coli.

    Science.gov (United States)

    Birnbaum, S; Bülow, L; Hardy, K; Danielsson, B; Mosbach, K

    1986-10-01

    We have determined and monitored the production and release of human proinsulin by genetically engineered Escherichia coli cells. Several M9 media samples were analyzed sequentially after centrifugation with the aid of a rapid automated flow-through thermometric enzyme-linked immunosorbent assay (TELISA) system. The response time was 7 min after sample injection and a single assay was complete after 13 min. Insulin concentrations in the range of 0.1-50 micrograms/ml could be determined. The TELISA method correlated well with conventional radioimmunoassay determinations. Standard curves were reproducible over a period of several days even when the immobilized antibody column was stored at 25 degrees C in the enzyme thermistor unit. Thus, immediate assay start up was possible.

  9. Detection of phase I IgG antibodies to Coxiella burnetii with EIA as a screening test for blood donations

    NARCIS (Netherlands)

    van der Hoek, W.; Wielders, C. C. H.; Schimmer, B.; Wegdam-Blans, M. C. A.; Meekelenkamp, J.; Zaaijer, H. L.; Schneeberger, P. M.

    2012-01-01

    The presence of a high phase I IgG antibody titre may indicate chronic infection and a risk for the transmission of Coxiella burnetii through blood transfusion. The outbreak of Q fever in the Netherlands allowed for the comparison of an enzyme immunoassay (EIA) with the reference immunofluorescence

  10. Comparison of conventional culture methods and two commercial enzyme immunoassays for detection of Salmonella in porcine fecal samples and cecal contents

    DEFF Research Database (Denmark)

    Wegener, Henrik Caspar; Baggesen, Dorte Lau

    1997-01-01

    Two commercial enzyme immunoassays, designated EIA-1 and EIA-2, for the detection of salmonella in feces and cecal contents were compared to conventional culture methods. Out of 362 cecal content samples, 35 were positive by EIA-1 and 30 were positive by EIA-2 and conventional methods. Out of 189...

  11. Evaluation of three commercial rapid tests for detecting antibodies to human immunodeficiency virus.

    Science.gov (United States)

    Ng, K P; Saw, T L; Baki, A; Kamarudin, R

    2003-08-01

    Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest are simple/rapid tests for the detection of antibodies to HIV-1 and HIV-2 in human whole blood, serum and plasma samples. The assay is one step and the result is read visually within 15 minutes. Using 92 known HIV-1 reactive sera and 108 known HIV-1 negative sera, the 3 HIV tests correctly identified all the known HIV-1 reactive and negative samples. The results indicated that Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest HIV are as sensitive and specific (100% concordance) as Microparticle Enzyme Immunoassay. The data indicated that these 3 HIV tests are effective testing systems for diagnosis of HIV infection in a situation when the conventional Enzyme Immunoassay is not suitable.

  12. Sources of variation in an enzyme-linked immunoassay of bluetongue virus in Culicoides variipennis (Diptera: Ceratopogonidae).

    Science.gov (United States)

    Tabachnick, W J; Mecham, J O

    1991-03-01

    An enzyme-linked immunoassay for detecting bluetongue virus in infected Culicoides variipennis was evaluated using a nested analysis of variance to determine sources of experimental error in the procedure. The major source of variation was differences among individual insects (84% of the total variance). Storing insects at -70 degrees C for two months contributed to experimental variation in the ELISA reading (14% of the total variance) and should be avoided. Replicate assays of individual insects were shown to be unnecessary, since variation among replicate wells and plates was minor (2% of the total variance).

  13. Estrogen receptor determination in endometrial carcinoma: ligand binding assay versus enzyme immunoassay

    DEFF Research Database (Denmark)

    Nyholm, H C; Nielsen, Anette Lynge; Lyndrup, J

    1995-01-01

    We compared concentrations of cytosolic estrogen receptors (ERc) measured in 35 postmenopausal endometrial carcinomas by ligand binding method (LBA) (dextran-coated charcoal assay) and enzyme immunoassay (EIA). Correlations between ERc, nuclear estrogen receptors (ERn) determined by EIA......, and cytosolic progesterone receptors (PR) measured by LBA were also studied. While ERc concentrations determined by LBA and EIA were highly correlated (r: 0.94), ERc values detected by LBA were approximately twice those found by EIA (median values of ERc: 155 vs. 64 fmol/mg cytosol protein, DCC vs. EIA......). The percentages of ERc positive tumors were 89% by LBA and 77% by EIA. The median fraction of total ER present as ERn was 63%. PR levels correlated positively with ERn concentrations (r: 0.73). We explore possible reasons why greater concentrations of ERc are determined by estradiol binding than by the ER-EIA kit...

  14. Comparison of neutralizing and hemagglutination-inhibiting antibody responses to influenza A virus vaccination of human immunodeficiency virus-infected individuals

    NARCIS (Netherlands)

    Benne, CA; Harmsen, M; Tavares, L; Kraaijeveld, CA; De Jong, JC

    A neutralization enzyme immunoassay (N-EIA) was used to determine the neutralizing serum antibody titers to influenza A/Taiwan/1/86 (H1N1) and Beijing/353/89 (H3N2) viruses after vaccination of 51 human immunodeficiency virus (HIV) type 1-infected individuals and 10 healthy noninfected controls

  15. [EIA-IgG antibody measles prevention level estimated from measles neutralizing, particle agglutination and hemagglutination-inhibition antibody titer].

    Science.gov (United States)

    Takayama, Naohide; Saika, Shizuko; Ichinohe, Sadato

    2009-09-01

    Measles hemagglutination inhibition (HI) antibody titer, widely used in clinical practice to simply and easily determine the measles immunity level has, in recent years, been increasingly replaced by measles IgG-antibody titer determined by enzyme-immunoassay (EIA). HI antibody titer appears to reflect this protective level, because HI measures the antibody against H protein required for the measles virus to adhere to host cells. EIA-IgG antibody titer does not correlate with the protective level, similar to particle agglutination (PA) titer, because EIA measures different antibodies, including those unrelated to measles protection. After determining HI, PA, neutralizing test (NT) results, and EIA-IgG antibody titer for individual specimens, we compared EIA-IgG antibody titer obtained using an EIA-Kit (Denka Seiken) to HI, PA, and NT titer with the following results: (1) Subjects with EIA-IgG titer of > or = 12.0 may be protected against measles: (2) Subjects with EIA-IgG titer of 4.0 to 8.0 appear to be protected insufficiently requiring a booster dose against measles: (3) Subjects with EIA-IgG titer of 8.0 to 12.0 may benefit from booster vaccination.

  16. Automated thermometric enzyme immunoassay of human proinsulin produced by Escherichia coli

    International Nuclear Information System (INIS)

    Birnbaum, S.; Buelow, L.; Hardy, K.; Danielsson, B.; Mosbach, K.

    1986-01-01

    The authors have determined and monitored the production and release of human proinsulin by genetically engineered Escherichia coli cells. Several M9 media samples were analyzed sequentially after centrifugation with the aid of a rapid automated flow-through thermometric enzyme-linked immunosorbent assay (TELISA) system. The response time was 7 min after after sample injection and a single assay was complete after 13 min. Insulin concentrations in the range of 0.1-50 μg/ml could be determined. The TELISA method correlated well with conventional radioimmunoassay determinations. Standard curves were reproducible over a period of several days even when the immobilized antibody column was stored at 25 0 C in the enzyme thermistor unit. Thus, immediate assay start up was possible

  17. Immobilization of enzyme and antibody by low energy electron beam polymerization

    International Nuclear Information System (INIS)

    Kaetsu, Isao; Kumakura, Minoru

    1987-01-01

    Immobilization of glucoamylase and AFP-antibody was studied using an electron beam of relatively low energy. A thin polymer membrane formed by irradiation of monomer enzyme mixture in a buffer, which had a considerable enzymatic activity. A membrane of almost the same thickness and activity was obtained by repeated irradiation. The effect of irradiation conditions on the immobilization and the variations of irradiation method for immobilization were investigated. The immobilization of antibody was carried out in similar ways as for enzyme, and the product also showed a considerable activity. (author)

  18. Magnetic Particle-Based Immunoassay of Phosphorylated p53 Using Protein-Cage Templated Lead Phosphate and Carbon Nanospheres for Signal Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Aiqiong; Bao, Yuanwu; Ge, Xiaoxiao; Shin, Yongsoon; Du, Dan; Lin, Yuehe

    2012-11-20

    Phosphorylated p53 at serin 15 (phospho-p53-15) is a potential biomarker of Gamma-radiation exposure. In this paper, we described a new magnetic particles (MPs)-based electrochemical immunoassay of human phospho-p53-15 using carbon nanospheres (CNS) and protein-cage templated lead phosphate nanoparticles for signal amplification. Greatly enhanced sensitivity was achieved by three aspects: 1) The protein-cage nanoparticle (PCN) and p53-15 signal antibody (p53-15 Ab2) are linked to CNS (PCNof each apoferritin; 3) MPs capture a large amount of primary antibodies. Using apoferritin templated metallic phosphate instead of enzyme as label has the advantage of eliminating the addition of mediator or immunoreagents and thus makes the immunoassay system simpler. The subsequent stripping voltammetric analysis of the released lead ions were detected on a disposable screen printed electrode. The response current was proportional to the phospho-p53-15 concentration in the range of 0.02 to 20 ng mL-1 with detection limit of 0.01 ng mL-1. This method shows a good stability, reproducibility and recovery.

  19. Locus-specific detection of HLA-DQ and -DR antigens by antibodies against synthetic N-terminal octapeptides of the beta chain

    DEFF Research Database (Denmark)

    Deufel, T; Grove, A; Kofod, Hans

    1985-01-01

    Antibodies against synthetic peptides representing the class-II antigen HLA-DR and -DQ beta chain N-terminal sequences were prepared in rabbits. The two octapeptides only share two amino acids and enzyme-linked immuno-assays showed the antisera only to bind to its own antigen. Both peptide antisera...... chains of HLA-DR and -DQ have been prepared by the preparation by the production of antibodies against the N-terminal sequences of each polypeptide....

  20. An enzyme-immunobinding assay for fast screening of expression of tissue plasminogen activator cDNA in E. coli

    International Nuclear Information System (INIS)

    Tang, J.C.T.; Li, S.H.

    1984-01-01

    Tissue plasminogen activator (TPA) has been isolated from normal human tissues and certain human cell lines in culture. The enzyme is a serine protease which converts an inactive zymogen, plasminogen to plasmin, and causes lysis of fibrin clots. The high affinity of TPA for fibrin indicates that it is a potential thrombolytic agent and is superior to urokinase-like plasminogen activators. Recently, TPA has been cloned and expressed in E. coli. Using TPA as a model protein, the authors report here the development of a direct, sensitive enzyme-immunoassay for the screening of a cDNA expression library using specific antibodies and peroxidase-labeled second antibody

  1. A three-parameter langmuir-type model for fitting standard curves of sandwich enzyme immunoassays with special attention to the α-fetoprotein assay

    NARCIS (Netherlands)

    Kortlandt, W.; Endeman, H.J.; Hoeke, J.O.O.

    In a simplified approach to the reaction kinetics of enzyme-linked immunoassays, a Langmuir-type equation y = [ax/(b + x)] + c was derived. This model proved to be superior to logit-log and semilog models in the curve-fitting of standard curves. An assay for α-fetoprotein developed in our laboratory

  2. Enzyme-linked immunosorbent assay (ELISA) using a specific monoclonal antibody as a new tool to detect Sudan dyes and Para red

    International Nuclear Information System (INIS)

    Ju Chunmei; Tang Yong; Fan Huiying; Chen Jinding

    2008-01-01

    To set up an immunoassay-based method to detect Sudan dyes and Para red, we generated a monoclonal antibody (Mab) using a specially designed carboxyl derivative of Sudan I (CSD I) as the immunogen. CSD I was synthesized by azocoupling reaction using 2-naphthol and diazotised 4-aminobenzoic acid. The antibody was obtained from a hybridoma, which was derived from the fusion of the mouse myeloma SP2/0 cells and the splenocytes from the mice immunized with the CSD I-bovine serum albumin (BSA) conjugate. In addition, we showed that the Mab was highly specific for Sudan I, III and Para red. The limit of detection was approximately 0.01 ng mL -1 in phosphate-buffered saline (PBS) buffer and 0.5 ng g -1 in chilli tomato sauce. The recoveries of Sudan I, III and Para red for the chilli tomato sauce were from 84% to 99% and coefficients of variation were from 14.9% to 33.3%. Thus, the enzyme-linked immunosorbent assay (ELISA) method is a rapid and high throughput screening tool to detect Sudan dyes and Para red in food products

  3. Enzyme-linked immunosorbent assay (ELISA) using a specific monoclonal antibody as a new tool to detect Sudan dyes and Para red

    Energy Technology Data Exchange (ETDEWEB)

    Ju Chunmei [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China); Tang Yong [Center of Antibody Engineering, Department of Bioengineering, Jinan University, Guangzhou 510632 (China); Fan Huiying [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China); Chen Jinding [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China)], E-mail: jdchen@scau.edu.cn

    2008-07-28

    To set up an immunoassay-based method to detect Sudan dyes and Para red, we generated a monoclonal antibody (Mab) using a specially designed carboxyl derivative of Sudan I (CSD I) as the immunogen. CSD I was synthesized by azocoupling reaction using 2-naphthol and diazotised 4-aminobenzoic acid. The antibody was obtained from a hybridoma, which was derived from the fusion of the mouse myeloma SP2/0 cells and the splenocytes from the mice immunized with the CSD I-bovine serum albumin (BSA) conjugate. In addition, we showed that the Mab was highly specific for Sudan I, III and Para red. The limit of detection was approximately 0.01 ng mL{sup -1} in phosphate-buffered saline (PBS) buffer and 0.5 ng g{sup -1} in chilli tomato sauce. The recoveries of Sudan I, III and Para red for the chilli tomato sauce were from 84% to 99% and coefficients of variation were from 14.9% to 33.3%. Thus, the enzyme-linked immunosorbent assay (ELISA) method is a rapid and high throughput screening tool to detect Sudan dyes and Para red in food products.

  4. Development of Indirect Competitive Immuno-Assay Method Using SPR Detection for Rapid and Highly Sensitive Measurement of Salivary Cortisol Levels

    International Nuclear Information System (INIS)

    Tahara, Yusuke; Huang, Zhe; Kiritoshi, Tetsuro; Onodera, Takeshi; Toko, Kiyoshi

    2014-01-01

    The monitoring of salivary cortisol as a key biomarker of an individual’s stress response has been increasingly focused on. This paper describes the development of a novel cortisol immuno-assay method based on an indirect competitive method using a commercially available surface plasmon resonance instrument. The surface of an Au chip was modified with PEG6-COOH aromatic dialkanethiol self-assembled monolayers and hydrocortisone 3-(O-carboxymethyl) oxime (hydrocortisone 3-CMO) as a cortisol analog. A detection limit of 38 ppt range with a measurement range of 10 ppt–100 ppb was accomplished without the incubation of a mixing solution consisting of standard cortisol and an anti-cortisol antibody, and the time for quantification of cortisol concentration was 8 min from the sample injection. We experimentally compared our immuno-assay with a commercialized salivary cortisol enzyme-linked immunosorbent assay (ELISA) kit using human saliva samples. It was found that the results obtained by the cortisol immuno-assay had a good correlation with those obtained by ELISA assay (R = 0.96). Our findings indicate the potential utility of the cortisol immuno-assay for measurements of human salivary cortisol levels.

  5. Development of Indirect Competitive Immuno-Assay Method Using SPR Detection for Rapid and Highly Sensitive Measurement of Salivary Cortisol Levels

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yusuke; Huang, Zhe; Kiritoshi, Tetsuro [Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka (Japan); Onodera, Takeshi [Research and Development Center for Taste and Odor Sensing, Kyushu University, Fukuoka (Japan); Toko, Kiyoshi, E-mail: toko@ed.kyushu-u.ac.jp [Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka (Japan); Research and Development Center for Taste and Odor Sensing, Kyushu University, Fukuoka (Japan)

    2014-05-30

    The monitoring of salivary cortisol as a key biomarker of an individual’s stress response has been increasingly focused on. This paper describes the development of a novel cortisol immuno-assay method based on an indirect competitive method using a commercially available surface plasmon resonance instrument. The surface of an Au chip was modified with PEG6-COOH aromatic dialkanethiol self-assembled monolayers and hydrocortisone 3-(O-carboxymethyl) oxime (hydrocortisone 3-CMO) as a cortisol analog. A detection limit of 38 ppt range with a measurement range of 10 ppt–100 ppb was accomplished without the incubation of a mixing solution consisting of standard cortisol and an anti-cortisol antibody, and the time for quantification of cortisol concentration was 8 min from the sample injection. We experimentally compared our immuno-assay with a commercialized salivary cortisol enzyme-linked immunosorbent assay (ELISA) kit using human saliva samples. It was found that the results obtained by the cortisol immuno-assay had a good correlation with those obtained by ELISA assay (R = 0.96). Our findings indicate the potential utility of the cortisol immuno-assay for measurements of human salivary cortisol levels.

  6. Immunoassays for riboflavin and flavin mononucleotide using antibodies specific to d-ribitol and d-ribitol-5-phosphate.

    Science.gov (United States)

    Ravi, G; Venkatesh, Yeldur P

    2017-06-01

    Riboflavin (vitamin B 2 ), a water-soluble vitamin, plays a key role in maintaining human health. Though, numerous methods have been reported for the determination of total riboflavin (TRF) content in foods and biological samples, very few methods are reported for quantifying riboflavin and its coenzymes [flavin mononucleotide (FMN); flavin adenine dinucleotide (FAD)] individually. Recently, we have demonstrated that antibodies specific to d-ribitol and d-ribitol-5-phosphate also recognize riboflavin and FMN, respectively, and not vice-versa. In this study, we have evaluated these two antibodies for the analysis of riboflavin and FMN by indirect competitive ELISA (icELISA) in selected foods and pharmaceuticals. Under the optimal assay conditions, 50% inhibition concentration (IC 50 ) and limit of detection (LOD, IC 10 ) were 3.41ng/mL and 0.02ng/mL for riboflavin, and 7.84ng/mL and 0.24ng/mL for FMN, respectively, with detectable concentration range between 0.1 and 100ng of analytes and riboflavin and FMN) from the same food samples showed variation in their values compared to TRF, and were in good agreement with values obtained from HPLC and AOAC methods. Further, spiking and recovery analysis of food samples and pharmaceuticals showed no significant matrix effects. The immunoassays were validated in terms of accuracy and precision using inter- and intra-assays. The immunoassays developed in this study are sensitive and appears feasible for screening a large number of samples in the quantification of riboflavin and FMN in various biological samples, pharmaceuticals and natural/processed foods. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Detection of Total Ergot Alkaloids in Cereal Flour and in Bread by a Generic Enzyme Immunoassay Method.

    Science.gov (United States)

    Gross, Madeleine; Curtui, Valeriu; Usleber, Ewald

    2018-05-01

    Four sets of polyclonal antibodies against ergot alkaloids ergometrine, ergotamine, α-ergocryptine, and ergocornine were produced and characterized in a competitive direct or indirect enzyme immunoassay (EIA). Standard curve LODs were 0.03 ng/mL (ergometrine EIA) to 2.0 ng/mL (ergocornine EIA). Three EIAs were highly specific, whereas the ergometrine EIA had a broad specificity pattern and reacted, albeit weakly, with all seven major ergot alkaloids and their epimeric forms. Using the ergometrine EIA, a generic test system was established in which total ergot alkaloids are quantified by a standard curve for a toxin mixture composed of three alkaloids that matched the ergot alkaloid composition in naturally contaminated rye and wheat products. Sample extraction with acetonitrile-phosphate-buffered saline at pH 6.0 without further cleanup was sufficient for EIA analysis. The LODs for total ergot alkaloids were 20 ng/g in rye and wheat flour and 14 ng/g in bread. Recoveries were 85-110% (RSDs of 0.1-11.7%) at a concentration range of 50-1000 ng/g. The total ergot alkaloid EIA was validated by comparison with HPLC-fluorescence detection. Although some under- and overestimation by the total ergot alkaloid EIA was observed, it was suitable for the reliable identification of positive samples at 10-20 ng/g and for the determination of total ergot alkaloids in a concentration range between 100 and 1000 ng/g.

  8. Effect of using heat-inactivated serum with the Abbott human T-cell lymphotropic virus type III antibody test.

    OpenAIRE

    Jungkind, D L; DiRenzo, S A; Young, S J

    1986-01-01

    The Abbott enzyme immunoassay (Abbott Laboratories, North Chicago, Ill.) for human T-cell lymphotropic virus type III (HTLV-III) antibody was evaluated to determine the effect of using heat-inactivated (56 degrees C for 30 min) serum as the sample. Each of 58 nonreactive serum samples gave a higher A492 value when tested after heat inactivation. Ten of the samples became reactive after heating. Heat-inactivated serum should not be used in the current Abbott HTLV-III antibody test, because thi...

  9. Towards the development of a radioenzyme-immunoassay

    International Nuclear Information System (INIS)

    Schuurs, A.H.W.M.; Waart, M. v. d.

    1976-01-01

    We have tried to develop a very sensitive enzyme-immunoassay. For this purpose, a very sensitive radiochemical enzyme assay was used. HCG was chosen as test model and AChE as labelling enzyme. The test appeared to be much more sensitive than the normal enzymeimmunoassay. And, in comparison with RIA, it was about as sensitive but less time-consuming, and it makes use, in principle, of stable reagents. (orig./GSE) [de

  10. Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan

    2016-09-01

    The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.

  11. Development of Immunoassay Based on Monoclonal Antibody Reacted with the Neonicotinoid Insecticides Clothianidin and Dinotefuran

    OpenAIRE

    Uchigashima, Mikiko; Watanabe, Eiki; Ito, Shigekazu; Iwasa, Seiji; Miyake, Shiro

    2012-01-01

    Enzyme-linked immunosorbent assay (ELISA) based on a monoclonal antibody (MoAb) was developed for the neonicotinoid insecticide clothianidin. A new clothianidin hapten (3-[5-(3-methyl-2-nitroguanidinomethyl)-1,3-thiazol-2-ylthio] propionic acid) was synthesized and conjugated to keyhole limpet hemocyanin, and was used for monoclonal antibody preparation. The resulting MoAb CTN-16A3-13 was characterized by a direct competitive ELISA (dc-ELISA). The 50% of inhibition concentration value with cl...

  12. Naturally acquired anthrax antibodies in a cheetah (Acinonyx jubatus) in Botswana.

    Science.gov (United States)

    Good, Kyle M; Houser, Annmarie; Arntzen, Lorraine; Turnbull, Peter C B

    2008-07-01

    An outbreak of anthrax in the Jwana Game Reserve in Jwaneng, Botswana, was first observed when three cheetahs (Acinonyx jubatus) died of the disease in November 2004. In the aftermath of this event, banked serum samples collected from 23 wild-caught cheetahs were examined, by the inhibition enzyme-linked immunoassay (ELISA), for antibodies to the protective antigen (PA) of Bacillus anthracis. Of the 23 cheetahs, 16 regularly accessed the reserve. Antibodies to PA were detected in one cheetah collected in May 2004, indicating the disease was occurring well before it was first noticed. This appears to be the first demonstration of naturally acquired anthrax antibodies in cheetahs. The finding of one antibody-positive animal amongst at least 16 potentially exposed individuals is consistent with existing reports that it is uncommon for cheetahs to develop natural immunity to anthrax.

  13. Kinase Activity Studied in Living Cells Using an Immunoassay

    Science.gov (United States)

    Bavec, Aljos?a

    2014-01-01

    This laboratory exercise demonstrates the use of an immunoassay for studying kinase enzyme activity in living cells. The advantage over the classical method, in which students have to isolate the enzyme from cell material and measure its activity in vitro, is that enzyme activity is modulated and measured in living cells, providing a more…

  14. Measurements in international units of antibody to hepatitis B surface antigen(anti-HBs) after immunization with a yeast-derived, subtype adr hepatitis B vaccine are considerably different between chemiluminescent immunoassay (CLIA) and chemiluminescent enzyme immunoassay (CLEIA).

    Science.gov (United States)

    Ogata, Norio

    2006-04-01

    The worldwide consensus of the minimum protective anti-HBs level against HBV infection is 10 mIU/mL on assays standardized by the World Health Organization (WHO) reference preparations. To investigate whether this value could be applied to recipients of yeast-derived recombinant HB vaccine containing the major surface protein of subtype adr (Bimmugen, Astellas Pharmaceutical, Tokyo), we compared anti-HBs measurements between chemiluminescent immunoassay (CLIA) (Architect Ausab, Abbott Japan, Tokyo) and chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse Forte, Fujirebio, Tokyo) in given serum samples obtained from the vaccinees. The vaccine and the two assay methods are currently in a wide use in Japan. The study included 300 medical students who completed a standard vaccination course (0, 1 and 6 months). Serum samples obtained 1 month or 13 months after completing the vaccination were simultaneously tested for anti-HBs by CLIA and CLEIA. In 147 samples with quantifiable values on both CLIA and CLEIA (10 to 1000 mIU/mL) the geometric mean titer on CLEIA (225.0 mIU/mL) was significantly higher than that on CLIA (94.5 mIU/mL) (p < 0.0001). Of 26 subjects with CLIA measurements below 10 mIU/mL, 15 samples (57.7%) showed CLEIA measurements more than 10 mIU/mL. Thus, in the subtype adr-vaccinees CLEIA demonstrated considerably high serum anti-HBs measurements compared to CLIA and discordance in determining critical anti-HBs level of 10 mIU/mL was observed in more than half the samples. This suggests that the minimum HBV-protective anti HBs titer of 10 mIU/mL is difficult to be introduced to Japan where subtype adr-HB vaccines or -HBV infection are prevalent, unless characteristics of assay methods are carefully evaluated.

  15. Comparison of immunoglobulin E measurements on IMMULITE and ImmunoCAP in samples consisting of allergen-specific mouse-human chimeric monoclonal antibodies towards allergen extracts and four recombinant allergens

    DEFF Research Database (Denmark)

    Szecsi, Pal B; Stender, Steen

    2013-01-01

    Specific immunoglobulin E (IgE) antibody in vitro tests are performed on enzyme immunoassay systems. Poor agreement among systems has been reported and comparisons have been made exclusively with allergen extracts - not with recombinant allergens. Here we compare the ImmunoCAP and the IMMULITE sy...

  16. Homogeneous immunoassay for human IgG using oriented hen egg IgY immobilized on gold sol nanoparticles

    International Nuclear Information System (INIS)

    Yeritsyan, H.E.; Gasparyan, V.K.

    2012-01-01

    Homogeneous immunoassays using (red) gold nanoparticles represent an attractive detection scheme because of the option of photometric readout. We have applied oriented immobilization of hen egg immunoglobulin Y (IgY) on gold nanoparticles when developing a homogeneous immunoassay for human IgG. In oriented immobilization, as opposed to random immobilization, the antigen binding capabilities of the antibodies are retained. It is shown that such immunoassay has significantly better sensitivity in comparison with methods based on conventional immobilization of affinity-purified antibodies. It is also shown that hen egg IgY is better suited than rabbit antibodies, because much more antibody can be immobilized on gold nanoparticles without any destabilization, probably because of the more acidic nature of these antibodies. In addition, hen egg IgY can be supplied in higher quantity and can be prepared more easily than IgG from rabbits. Bleeding and slaughtering of animals is not needed. The assay presented here has a wide detection range (30-500 ng. mL -1 ) and a limit of detection as low as 30 ng. mL -1 of human IgG. (author)

  17. The clinical value of enzyme-multiplied immunoassay technique monitoring the plasma concentrations of cyclosporine A after renal transplantation

    Directory of Open Access Journals (Sweden)

    Xiao-Hui Luo

    2011-05-01

    Full Text Available The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT monitoring of blood concentrations of cyclosporine A (CsA in patients treated with CsA were investigated after kidney transplantation. The validation method was performed to the EMIT determination of CsA blood concentration, the CsA whole blood ‘trough concentrations (C0 of patients in different time periods after renal transplantation were monitored, and combined with the clinical complications, the statistical results were analyzed and compared. EMIT was precise, accurate and stable, also with a high quality control. The mean postoperative blood concentration of CsA was as follows: 12 months, (185.6 ± 28.1ng/mL. The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14. 1%, significantly lower than that of the none-recommended dose group (37.2% (P < 0.05; the transplantation rejection rate was 4.4%, significantly lower than that of the none-recommended dose group (22.5% (P < 0.05. Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible, and is able to reduce the CsA toxicity and rejection significantly, leading to achieving the desired therapeutic effect. Keywords: enzyme-multiplied immunoassay technique, renal transplantation, cyclosporin A, blood concentration monitoring

  18. Double Antibody Method for Immunoassay of Insulin. Its Application in Population Studies

    Energy Technology Data Exchange (ETDEWEB)

    Welborn, T. A.; Stenhouse, N. S.; Curnow, D. H.; Johnstone, Clare J. [Department of Medicine, Raine Foundation Medical Statistics Unit and Department of Pathology, University of Western Australia, Perth (Australia)

    1970-02-15

    The performance of a double-antibody Immunoassay technique over a period of two years is described, during which 3300 samples from population studies were analysed for insulin concentration. The method requires safeguards to ensure that complete separation of ''free'' from ''antibody-bound'' hormone is achieved, thus labelled gamma-globulin is used in the precise preliminary standardization of precipitating antibody. The dose-response curves for crystalline insulin standards over a range of concentration 0.2 to 16,0 ng (5 to 400 micro-International-Units)/ml are consistently nonlinear, but a close fit is obtained by a cubic function obtained empirically from multiple regression analysis, which also corrects satisfactorily for ''within-assay drift'' when large numbers of samples are involved. The coefficient of variation for pooled serum standards repetitively assayed ranged from 10 to 14%. Sources of ''between-assay variability'' of the serum standards include variable integrity of the labelled insulin and the slope of the standard curve. For quality control material, the need for standards of serum as well as crystalline insulin is stressed, Serum-insulin was measured in 3300 adults of the population of Busselton, approximately 1 h after a 50 g oral glucose load. The concentrations were distributed log-normally. Females had significantly higher 'one-hour' serum-insulin levels than males, and both sexes showed a moderate rise of values with age. Multiple regression analyses revealed that the major determinant of serum-insulin was the blood-sugar level, the independent relationship being such that at ''one-hour'' blood-sugar levels exceeding 160 - 180 mg/100 ml, a decline of insulin values occurred. Body-weight had a strong positive association, and height a negative relationship, with the ''one-hour'' serum-insulin. Males with coronary heart disease and hypertension showed elevated insulin levels under 60 years of age, whereas ''ideal'' males (with obesity

  19. Magnetic bead and gold nanoparticle probes based immunoassay for β-casein detection in bovine milk samples.

    Science.gov (United States)

    Li, Y S; Meng, X Y; Zhou, Y; Zhang, Y Y; Meng, X M; Yang, L; Hu, P; Lu, S Y; Ren, H L; Liu, Z S; Wang, X R

    2015-04-15

    In this work, a double-probe based immunoassay was developed for rapid and sensitive determination of β-casein in bovine milk samples. In the method, magnetic beads (MBs), employed as supports for the immobilization of anti-β-casein polyclonal antibody (PAb), were used as the capture probe. Colloidal gold nanoparticles (AuNPs), employed as a bridge for loading anti-β-casein monoclonal antibody (McAb) and horseradish peroxidase (HRP), were used as the amplification probe. The presence of β-casein causes the sandwich structures of MBs-PAb-β-casein-McAb-AuNPs through the interaction between β-casein and the anti-β-casein antibodies. The HRP, used as an enzymatic-amplified tracer, can catalytically oxidize the substrate 3,3',5,5'-tetramethylbenzidine (TMB), generating optical signals that are proportional to the quantity of β-casein. The linear range of the immunoassay was from 6.5 to 1520ngmL(-1). The limit of detection (LOD) was 4.8ngmL(-1) which was 700 times lower than that of MBs-antibody-HRP based immunoassay and 6-7 times lower than that from the microplate-antibody-HRP based assay. The recoveries of β-casein from bovine milk samples were from 95.0% to 104.3% that had a good correlation coefficient (R(2)=0.9956) with those obtained by an official standard Kjeldahl method. For higher sensitivity, simple sample pretreatment and shorter time requirement of the antigen-antibody reaction, the developed immunoassay demonstrated the viability for detection of β-casein in bovine milk samples. Copyright © 2014. Published by Elsevier B.V.

  20. Evaluation of a competitive enzyme-linked immunosorbent assay for measurements of soluble HLA-G protein

    DEFF Research Database (Denmark)

    Rasmussen, M; Dahl, M; Buus, S

    2014-01-01

    . We report a novel method, a competitive immunoassay, for measuring HLA-G5/sHLA-G1 in biological fluids. The sHLA-G immunoassay is based upon a competitive enzyme-linked immunosorbent assay (ELISA) principle. It includes a recombinant sHLA-G1 protein in complex with β2-microglobulin and a peptide...... as a standard, biotinylated recombinant sHLA-G1 as an indicator, and the MEM-G/9 anti-HLA-G monoclonal antibody (mAb) as the capture antibody. The specificity and sensitivity of the assay were evaluated. Testing with different recombinant HLA class I proteins and different anti-HLA class I mAbs showed....../ml. An intra-assay coefficient of variation (CV) of 15.5% at 88 ng/ml and an inter-assay CV of 23.1% at 39 ng/ml were determined. An assay based on the competitive sHLA-G ELISA may be important for measurements of sHLA-G proteins in several conditions: assisted reproduction, organ transplantation, cancer...

  1. Sensitive, Fast, and Specific Immunoassays for Methyltestosterone Detection

    Directory of Open Access Journals (Sweden)

    Na Kong

    2015-04-01

    Full Text Available An indirect competitive enzyme-linked immunosorbent assay (icELISA and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%–100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed.

  2. Effects of saliva collection using cotton swab on cortisol enzyme immunoassay.

    Science.gov (United States)

    Kozaki, Tomoaki; Hashiguchi, Nobuko; Kaji, Yumi; Yasukouchi, Akira; Tochihara, Yutaka

    2009-12-01

    Cotton swabs are among the most commonly used devices for collecting saliva, but various studies have reported that their use impacts the results of salivary cortisol assays. These studies, however, estimated this impact by comparing the average of the concentration and/or scatter plots. In the present study, we estimated the impact of cotton swabs on the results of salivary cortisol enzyme immunoassay (EIA) by Bland-Altman plot. Eight healthy males (aged 20-23 years) provided four saliva samples on different days to yield a total of 32 samples. Saliva samples were collected directly in plastic tubes using plastic straws and then pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). There was a lower correlation between cotton and passive saliva collection. Individually, four subjects showed a negative correlation between passive and cotton saliva collection. A Bland-Altman plot indicated that cotton swabs causes a proportional bias on the EIA assay result. Our findings indicate a considerable effect of using cotton swabs for saliva collection, and subject-specific variability in the impact. A Bland-Altman plot further suggests possible reasons for this effect.

  3. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    International Nuclear Information System (INIS)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong; Shi, Hanchang; Long, Feng

    2016-01-01

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  4. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong [School of Environment and Natural Resources, Renmin University of China, Beijing (China); Shi, Hanchang [School of Environment, Tsinghua University, Beijing (China); Long, Feng, E-mail: longf04@ruc.edu.cn [School of Environment and Natural Resources, Renmin University of China, Beijing (China)

    2016-01-28

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  5. Procedures for Sensitive Immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Givol, D. [Department of Chemical Immunology, Weizmann Institute of Science, Rehovot (Israel)

    1970-02-15

    Sensitive immunoassay methods should be applied to small molecules of biological importance, which are non-immunogenic by themselves, such as small peptide hormones (e.g. bradykinin), plant hormones (e.g. indoleacetic acid), nucleotides and other small molecules. Methods of binding these small molecules, as haptens, to immunogenic carriers by various cross-linking agents are described (dicyclohexylcarbodiimide, tolylene-diisocyanate and glutaraldehyde), and the considerations involved in relation to the methods of binding and the specificity of the antibodies formed are discussed. Some uses of antibody bound to bromoacetyl cellulose as an immuno adsorbent convenient for assay of immunoglobulins are described. Finally, the sensitive immunoassay method of chemically modified phage is described. This includes methods of binding small molecules (such as the dinitrophenyl group, penicillin, indoleacetic acid) or proteins (such as insulin, immunoglobulins) to phages. Methods of direct chemical conjugation, or an indirect binding via anti-phage Fab, are described. The phage inactivation method by direct plating and its modifications (such as decision technique and complex inactivation) are compared with the more simple end-point titration method. The inhibition of phage inactivation has some advantages as it does not require radioactive material, or expensive radioactive counters, and avoids the need for separation between bound and unbound antigen. Hence, if developed, it could be used as an alternative to radioimmunoassay. (author)

  6. Status of immunoassay as an analytical tool in environmental investigations

    International Nuclear Information System (INIS)

    Van Emon, J.M.

    2000-01-01

    Immunoassay methods were initially applied in clinical situations where their sensitivity and selectivity were utilized for diagnostic purposes. In the 1970s, pesticide chemists realized the potential benefits of immunoassay methods for compounds difficult to analyze by gas chromatography. This transition of the technology has extended to the analysis of soil, water, food and other matrices of environmental and human exposure significance particularly for compounds difficult to analyze by chromatographic methods. The utility of radioimmunoassays and enzyme immunoassays for environmental investigations was recognized in the 1980s by the U.S. Environmental Protection Agency (U.S. EPA) with the initiation of an immunoassay development programme. The U.S. Department of Agriculture (USDA) and the U.S. Food and Drug Administration (PDA) have investigated immunoassays for the detection of residues in food both from an inspection and a contamination prevention perspective. Environmental immunoassays are providing rapid screening information as well as quantitative information to fulfill rigorous data quality objectives for monitoring programmes

  7. Development and application of radioimmunoassays and enzyme immunoassays in microbiological and immunological diagnosis. 2

    International Nuclear Information System (INIS)

    Mueller, W.A.; Struy, H.; Holzwarth, F.

    1982-01-01

    Comparative studies of indirect immunofluorescence test (IT), complement binding reaction (CBR), enzyme- and radioimmunoassay (ELISA, RIA) for the detection of toxoplasma antibodies in sera of 513 patients are reported. The precision dependent on time, showed coefficients of variation from 3% to 12% (IFT 3%, CBR 10%, ELISA 12%, RIA 7%). The correlation of IFT and ELISA as well as RIA was relatively unfavourable (coefficient of correlation IFT/ELISA r = 0.52, IFT/RIA r = 0.54, RIA/ELISA r = 0.60). The ELISA is the most sensitive method for the detection of antibodies. The specificity of the Toxo-ELISA has to be improved by application of suitable fractions of antigens. (author)

  8. Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay

    Science.gov (United States)

    Shi, Jing; Xu, Mingxia; Tang, Qinghui; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-02-01

    A novel flow injection chemiluminescence immunoassay for simple, sensitive and low-cost detection of diclofenac was established based on specific binding of antigen and antibody. Carboxylic resin beads used as solid phase carrier materials provided good biocompatibility and large surface-to-volume ratio for modifying more coating antigen. There was a competitive process between the diclofenac in solution and the immobilized coating antigen to react with the limited binding sites of the polyclonal antibody to form the immunocomplex. The second antibody labelled with horseradish peroxidase was introduced into the immunosensor and trapped by captured polyclonal antibody against diclofenac, which could effectively amplify chemiluminescence signals of luminol-PIP-H2O2. Under optimal conditions, the diclofenac could be detected quantitatively. The chemiluminescence intensity decreased linearly with the logarithm of the diclofenac concentration in the range of 0.1-100 ng mL- 1 with a detection limit of 0.05 ng mL- 1 at a signal-to-noise ratio of 3. The immunosensor exhibited high sensitivity, specificity and acceptable stability. This easy-operated and cost-effective analytical method could be valuable for the diclofenac determination in real water samples.

  9. Detection of Pesticides and Pesticide Metabolites Using the Cross Reactivity of Enzyme Immunoassays

    Science.gov (United States)

    Thurman, E.M.; Aga, D.S.

    2001-01-01

    Enzyme immunoassay is an important environmental analysis method that may be used to identify many pesticide analytes in water samples. Because of similarities in chemical structure between various members of a pesticide class, there often may be an unwanted response that is characterized by a percentage of cross reactivity. Also, there may be cross reactivity caused by degradation products of the target analyte that may be present in the sample. In this paper, the concept of cross reactivity caused by degradation products or by nontarget analytes is explored as a tool for identification of metabolites or structurally similar compounds not previously known to be present in water samples. Two examples are examined in this paper from various water quality studies. They are alachlor and its metabolite, alachlor ethane sulfonic acid, and atrazine and its class members, prometryn and propazine. A method for using cross reactivity for the detection of these compounds is explained in this paper.

  10. Correlations between calcineurin phosphatase inhibition and cyclosporine metabolites concentrations in kidney transplant recipients: Implications for immunoassays

    DEFF Research Database (Denmark)

    Jørgensen, Kaj Anker; Karamperis, Nikolaos; Koefoed-Nielsen, Pernille Bundgaard

    2006-01-01

    by inhibiting the enzyme calcineurin phosphatase. Determination of the enzyme's activity is one of the most promising pharmacodynamic markers. It is unknown how calcineurin phosphatase inhibition correlates with various cyclosporine monitoring assays and what is the potential impact of metabolites...... by the enzyme multiplied immunoassay technique (EMIT) and by the polyclonal fluorescence polarization immunoassay (pFPIA). Calcineurin phosphatase activity was measured by its ability to dephosphorylate a previously phosphorylated 19-amino acid peptide. We found that calcineurin phosphatase inhibition...

  11. Correlations between calcineurin phosphatase inhibition and cyclosporine metabolites concentrations in kidney transplant recipients: implications for immunoassays

    DEFF Research Database (Denmark)

    Karamperis, N; Koefoed-Nielsen, PB; Brahe, P

    2006-01-01

    by inhibiting the enzyme calcineurin phosphatase. Determination of the enzyme's activity is one of the most promising pharmacodynamic markers. It is unknown how calcineurin phosphatase inhibition correlates with various cyclosporine monitoring assays and what is the potential impact of metabolites...... by the enzyme multiplied immunoassay technique (EMIT) and by the polyclonal fluorescence polarization immunoassay (pFPIA). Calcineurin phosphatase activity was measured by its ability to dephosphorylate a previously phosphorylated 19-amino acid peptide. We found that calcineurin phosphatase inhibition...

  12. Development and application of radioimmunoassays and enzyme immunoassays in microbiological and immunological diagnosis. 2. Comparative studies for the detection of toxoplasma antibodies with ELISA, RIA and other serological methods

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, W A; Struy, H; Holzwarth, F [Medizinische Akademie, Magdeburg (German Democratic Republic)

    1982-06-01

    Comparative studies of indirect immunofluorescence test (IT), complement binding reaction (CBR), enzyme- and radioimmunoassay (ELISA, RIA) for the detection of toxoplasma antibodies in sera of 513 patients are reported. The precision dependent on time, showed coefficients of variation from 3% to 12% (IFT 3%, CBR 10%, ELISA 12%, RIA 7%). The correlation of IFT and ELISA as well as RIA was relatively unfavourable (coefficient of correlation IFT/ELISA r = 0.52, IFT/RIA r = 0.54, RIA/ELISA r = 0.60). The ELISA is the most sensitive method for the detection of antibodies. The specificity of the Toxo-ELISA has to be improved by application of suitable fractions of antigens.

  13. Synthesis-based approach toward direct sandwich immunoassay for ciguatoxin CTX3C.

    Science.gov (United States)

    Oguri, Hiroki; Hirama, Masahiro; Tsumuraya, Takeshi; Fujii, Ikuo; Maruyama, Megumi; Uehara, Hisatoshi; Nagumo, Yoko

    2003-06-25

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of ciguatoxin CTX3C were prepared by immunization of mice with protein conjugates of rationally designed synthetic haptens, 3 and 4, in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C itself. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C at the ppb level with no cross-reactivity against other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin.

  14. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots.

    Science.gov (United States)

    Chen, Rui; Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua; Xiong, Yonghua

    2016-12-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H 2 O 2 ) and H 2 O 2 -sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H 2 O 2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H 2 O 2 , as well as the incubation time between H 2 O 2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10 2  CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10 3  CFU/mL to 1.18 × 10 6  CFU/mL were in the range of 65.88%-105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Fast and sensitive detection of enteropathogenic Yersinia by immunoassays.

    Science.gov (United States)

    Laporte, Jérôme; Savin, Cyril; Lamourette, Patricia; Devilliers, Karine; Volland, Hervé; Carniel, Elisabeth; Créminon, Christophe; Simon, Stéphanie

    2015-01-01

    Yersinia enterocolitica and Yersinia pseudotuberculosis, the two Yersinia species that are enteropathogenic for humans, are distributed worldwide and frequently cause diarrhea in inhabitants of temperate and cold countries. Y. enterocolitica is a major cause of foodborne disease resulting from consumption of contaminated pork meat and is further associated with substantial economic cost. However, investigation of enteropathogenic Yersinia species is infrequently performed routinely in clinical laboratories because of their specific growth characteristics, which make difficult their isolation from stool samples. Moreover, current isolation procedures are time-consuming and expensive, thus leading to underestimates of the incidence of enteric yersiniosis, inappropriate prescriptions of antibiotic treatments, and unnecessary appendectomies. The main objective of the study was to develop fast, sensitive, specific, and easy-to-use immunoassays, useful for both human and veterinary diagnosis. Monoclonal antibodies (MAbs) directed against Y. enterocolitica bioserotypes 2/O:9 and 4/O:3 and Y. pseudotuberculosis serotypes I and III were produced. Pairs of MAbs were selected by testing their specificity and affinity for enteropathogenic Yersinia and other commonly found enterobacteria. Pairs of MAbs were selected to develop highly sensitive enzyme immunoassays (EIAs) and lateral flow immunoassays (LFIs or dipsticks) convenient for the purpose of rapid diagnosis. The limit of detection of the EIAs ranged from 3.2 × 10(3) CFU/ml to 8.8 × 10(4) CFU/ml for pathogenic serotypes I and III of Y. pseudotuberculosis and pathogenic bioserotypes 2/O:9 and 4/O:3 of Y. enterocolitica and for the LFIs ranged from 10(5) CFU/ml to 10(6) CFU/ml. A similar limit of detection was observed for artificially contaminated human feces. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  16. Highly sensitive electrochemical immunoassay for human IgG using double-encoded magnetic redox-active nanoparticles

    International Nuclear Information System (INIS)

    Tang, D.; Tang, J.; Su, B.; Chen, H.; Chen, G.; Huang, J.

    2010-01-01

    A new sandwich-type electrochemical immunoassay was developed for the detection of human IgG using doubly-encoded and magnetic redox-active nanoparticles as recognition elements on the surface of a glassy carbon electrode modified with anti-IgG on nanogold particles. The recognition elements were synthesized by coating magnetic Fe3O4 nanoparticles with Prussian blue nanoparticles and then covered with peroxidase-labeled anti-IgG antibodies (POx-anti-IgG) on Prussian blue nanoparticles. The immunoelectrode displays very good electrochemical properties towards detection of IgG via using double-encoded magnetic redox-active nanoparticles as trace and hydrogen peroxide as enzyme substrate. Its limit of detection (10 pmol.L -1 ) is 10-fold better than that of using plain POx-anti-IgG secondary antibodies. The method was applied to the detection of IgG in serum samples, and an excellent correspondence with the reference values was found. (author)

  17. Comparison of a novel chemiluminescence enzyme immunoassay (CLEIA) with enzyme-linked immunosorbent assay (ELISA) for the determination of MPO-ANCA in patients with ANCA-associated vasculitis.

    Science.gov (United States)

    Hirose, Orie; Itabashi, Mitsuyo; Takei, Takashi; Nitta, Kosaku

    2015-03-01

    Myeloperoxidase (MPO) anti-neutrophil cytoplasmic antibody (ANCA) represents the serological hallmark of ANCA-associated vasculitis (AAV). We evaluated the analytical and diagnostic accuracy of chemiluminescence enzyme immunoassay (CLEIA) versus enzyme-linked immunosorbent assay (ELISA) for the detection of MPO-ANCA. A total of 242 sera obtained from 51 patients with AAV and 103 patients without AAV were tested for MPO-ANCA by ELISA (NephroScholor MPOANC II) and CLEIA (the STACIA MEBLux test). Disease activity in the patients with AAV was determined based on the Birmingham Vasculitis Activity Score. We analyzed the correlations between the MPO-ANCA titers determined by the CLEIA and those determined by the ELISA, and also between the MPO-ANCA titers and the disease activity. The MPO-ANCA titers determined by the CLEIA (x) were strongly correlated with those determined by the ELISA (y). The correlation could be expressed by the following equation in this study: y = 1.8x + 7.7 (r = 0.96; p ELISA yielded positive test results in 57 of the 242 sera (23.6%). The CLEIA yielded false-positive test results in 4 of the 120 sera obtained from the non-AAV patients (3.3%), whereas the ELISA yielded a false-positive result in only 1 of the 120 sera obtained from the non-AAV patients (0.8%). The sensitivity and specificity of the CLEIA for the diagnosis of AAV were 100% and 96.7%, respectively, while those of the ELISA were 94.3% and 99.2%, respectively. The sensitivity and specificity of the CLEIA for the prediction of active disease were 100% and 64.4%, respectively, while those of the ELISA were 94.3% and 73.6%, respectively. The false positivity rate of the CLEIA for MPO-ANCA tended to be high as compared with that of the ELISA. Also, according to the correlation coefficient between the results of the CLEIA and the ELISA calculated in this study, it is necessary to pay attention to the differences in the sensitivity and specificity between CLEIA and ELISA.

  18. Determination of phospholipid transfer proteins in rat tissues by immunoassays

    International Nuclear Information System (INIS)

    Teerlink, T.

    1983-01-01

    Several quantitative immunoassays have been developed for two phospholipid transfer proteins from rat liver, i.e. the phosphatidylcholine transfer protein and the non-specific lipid transfer protein. The development of a double-antibody radioimmunoassay for the phosphatidylcholine transfer protein is described. The transfer protein was labelled with iodine-125 by the mild glucose oxidase-lactoperoxidase method. Although less than one tyrosine residue per molecule of transfer protein was labelled, only 20% of the labelled transfer protein was immunoprecipitable. This value could be increased to 80% by purifying the labelled protein by affinity chromatography on a column of anti-phosphatidylcholine transfer protein-IgG coupled to Sepharose 4B. The radioimmunoassay was used to determine the levels of phosphatidylcholine transfer protein in homogenates and 105 000 xg supernatants from various rat tissues as well as several Morris hepatomas. An enzyme immunoassay for the non-specific lipid transfer protein is also described. The antiserum that was raised especially by the author was cross-reactive with the non-specific lipid transfer protein present in 105 000 xg supernatants from human, mouse and bovine liver. The non-specific lipid transfer protein lost its immunoreactivity upon labelling with iodine-125 using different labelling techniques. Therefore, a regular radioimmunoassay could not be developed. The results of these different assays were compared. (Auth.)

  19. Linkage of biomolecules to solid phases for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Topics covered by this lecture include a brief review of the principal methods of linkage of biomolecules to solid phase matrices. Copies of the key self explanatory slides are presented as figures together with reprints of two publications by the author dealing with a preferred chemistry for the covalent linkage of antibodies to hydroxyl and amino functional groups and the effects of changes in solid phase matrix and antibody coupling chemistry on the performance of a typical excess reagent immunoassay for thyroid stimulating hormone

  20. Detection of anti-tetanus toxoid antibody on modified polyacrylonitrile fibers.

    Science.gov (United States)

    Jain, Swati; Chattopadhyay, Sruti; Jackeray, Richa; Zainul Abid, C K V; Kumar, Manoj; Singh, Harpal

    2010-10-15

    Accurate determination of concentration of immunoglobulin (IgG) to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, immune competence in individual patients and to measure the prevalence of immunity in populations. Surface modified polyacrylonitrile (PAN) fibers were evaluated as a matrix to develop highly sensitive method for the detection of anti-tetanus antibody in a sandwich ELISA format. In the proposed method tetanus toxoid immobilized on modified PAN fibers was used to detect anti-tetanus antibody (raised in horse hence represented as horse anti-tetanus toxoid or HAT-Ab) with horse raddish peroxidase enzyme conjugated with Rabbit anti-Horse IgG (RAH-HRP) as the label within 2.5h. A sigmoidal pattern for the detection of different concentration of antibody ranging from 1.0 to 0.0001 IU mL(-1) was validated. The immunoassay recorded a very high sensitivity as concentration as low as 0.0005 IU mL(-1) of HAT-Ab was detected. The intra- and inter-assay precision for 3 parallel measurements of 0.01 and for 0.001 IU mL(-1) of antibody varied from 5.4% to 11% and 5.7% to 20% respectively. PAN fibers were also used to qualitatively access the presence of different level of anti-tetanus antibody spiked in human blood. Seroepidemiological studies to measure the immunity against tetanus were conducted with twenty-five human beings belonging to various age groups using modified PAN-ELISA. The sensitivity, specificity and the reproducibility of the developed immunoassay indicate the potential application of modified PAN fibers in the field of immunodiagnostics. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Quantitative analysis of the synthesis and secretion of type VII collagen in cultured human dermal fibroblasts with a sensitive sandwich enzyme-linked immunoassay.

    Science.gov (United States)

    Amano, Satoshi; Ogura, Yuki; Akutsu, Nobuko; Nishiyama, Toshio

    2007-02-01

    Type VII collagen is the major component of anchoring fibrils in the epidermal basement membrane. Its expression has been analyzed by immunostaining or Northern blotting, but rarely at the protein level. In this study, we have quantitatively examined the effects of ascorbic acid and various cytokines/growth factors on the protein synthesis and secretion of type VII collagen by human dermal fibroblasts in culture, using a developed, highly sensitive sandwich enzyme-linked immunoassay with two kinds of specific monoclonal antibodies against the non-collagenous domain-1. Ascorbic acid and its derivative induced a twofold increase in type VII collagen synthesis, and markedly increased the secretion of type VII collagen into the medium when compared with the control culture. This effect was not influenced by the presence of transforming growth factor-beta1 (TGF-beta1). The synthesis of type VII collagen was elevated by TGF-beta1, platelet-derived growth factor, tumor necrosis factor-alpha, and interleukin-1beta, but not by TGF-alpha. Thus, our data indicate that the synthesis and secretion of type VII collagen in human dermal fibroblasts are regulated by ascorbate and the enhancement of type VII collagen gene expression by cytokines/growth factors is accompanied with elevated production of type VII collagen at the protein level.

  2. Immunoassay for thymopoietin

    International Nuclear Information System (INIS)

    Goldstein, G.

    1979-01-01

    The patent describes the development of a radio-immunoassay for thymopoietin in biological samples. The method of raising antibodies to this polypeptide hormone is described. This is achieved by injecting a host animal with an antigen consisting of thymopoietin covalently bonded by glutaraldehyde to a carrier protein such as bovine serum albumin and equine globulin. Different methods of radiolabelling thymopoietin with 125 I for use as the tracer antigen are described. The Bolton-Hunter procedure was preferred to the chloramine-T method since direct iodination of the tyrosyl moieties of thymopoietin resulted in some loss of immunoreactivity. Systems for separating the antigen-antibody complex and unbound antigen are compared. Binding-inhibition curves for unlabelled thymopoietin in the assay employing polyethylene glycol separation showed a sensitivity of 5 ng thymopoietin/ml. However, using the double antibody or dextran coated charcoal separation techniques, the sensitivity of thymopoietin was 0.1 ng/ml. Thus these latter two procedures are thus especially suitable for measuring thymopoietin levels in serum or plasma samples. The assay was shown to be specific for thymopoietin, no significant displacement being produced by control polypeptides. (U.K.)

  3. Rapid detection of fungal alpha-amylase in the work environment with a lateral flow immunoassay

    NARCIS (Netherlands)

    Bogdanovic, J.; Koets, M.; Sander, I.; Wouters, I.; Meijster, T.; Heederik, D.J.J.; Amerongen, van A.; Doekes, G.

    2006-01-01

    Background Occupational allergen exposure assessment usually requires airborne dust sampling at the worksite followed by dust extraction and enzyme immunoassay (EIA) analysis at the laboratory. Use of semiquantitative lateral flow immunoassays (LFIAs) may allow a more rapid detection procedure with

  4. Chemiluminescence immunoassay for chloramphenicol

    International Nuclear Information System (INIS)

    Lin Si; Xu Wenge; Liu Yibing

    2007-06-01

    A simple, solid-phase chemiluminescence immunoassay (CLIA) for the measurement of Chloramphenicol(CAP) in foodstuffs is described. A rabbit anti-CAP IgG is passively adsorbed onto the walls of polypropylene plates. The labeled conjugant is horseradish peroxidase(HRP) conjugate of CAP. Luminol solution is used as the substrate of HRP. The light yield is inversely proportional to the concentration of CAP. The method has a similar sensitivity (0.05 ng/mL), specificity, precision, and accuracy to a conventional enzyme immunoassay (EIA). The intra-assay and inter-assay CVs of ten samples were <8 and <20%, respectively, and the analytical recovery of the method was 87% 100%. The experimental correlation coefficient of dilution was found to be 0.999 using milk supernatant as buffer. The assay range for the method was 0.1-10 ng/mL, and it displayed good linearity. (authors)

  5. IMMUNOASSAYS FOR THE DETECTION OF UROKINASE RECEPTOR FORMS

    DEFF Research Database (Denmark)

    2004-01-01

    amounts of uPAR forms in a sample with data indicative of the presence of the cancer disease. The method can be used for staging, prognosis or diagnosis of prostate cancer. Two novel monoclonal antibodies and a kit and immunoassays for detecting at least one uPAR form(s) are also described in the present...

  6. Evaluation of the microparticle enzyme immunoassay Abbott IMx Select Chlamydia and the importance of urethral site sampling to detect Chlamydia trachomatis in women.

    OpenAIRE

    Brokenshire, M K; Say, P J; van Vonno, A H; Wong, C

    1997-01-01

    OBJECTIVE: To evaluate the commercial microparticle enzyme immunoassay (MEIA), Abbott IMx Select Chlamydia, for the detection of Chlamydia trachomatis in women and to compare its performance with endocervical cell culture. Also, to determine whether sampling the urethral site is an important part of chlamydial diagnosis in women. SETTING: The Auckland, Manukau, and Waitakere Sexual Health Clinics, Auckland, New Zealand and the Department of Clinical Microbiology, Auckland Hospital, Auckland, ...

  7. High prevalence of antibodies against hepatitis A virus among captive nonhuman primates.

    Science.gov (United States)

    Sa-nguanmoo, Pattaratida; Thawornsuk, Nutchanart; Rianthavorn, Pornpimol; Sommanustweechai, Angkana; Ratanakorn, Parntep; Poovorawan, Yong

    2010-04-01

    Hepatitis A virus (HAV) can infect not only humans but also several other nonhuman primates. This study has been conducted to evaluate the comprehensive anti-HAV seroprevalence in captive nonhuman primate populations in Thailand. The prevalence of antibodies against HAV in 96 captive nonhuman primates of 11 species was evaluated by competitive enzyme immunoassay (EIA). HAV antibodies were found in 64.7% (11/17) of macaques, 85.7% (6/7) of langurs, 28.4% (10/35) of gibbons, and 94.6% (35/37) of orangutans. However, anti-HAV IgM was not found in any sera. These results indicate that the majority of captive nonhuman primates in Thailand were exposed to HAV. It is possible that some of the animals were infected prior to capture.

  8. Detection of eosinophil cationic protein (ECP) by an enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Reimert, C M; Venge, P; Kharazmi, A

    1991-01-01

    Eosinophil cationic protein (ECP) is a highly basic and potent cytotoxic single-chain zinc-containing protein present in the granules of the eosinophilic granulocytes. ECP appears to be involved in defence against parasites and in the tissue damage seen in subjects with allergic and inflammatory...... disease. To investigate ECP release from in vitro activated human eosinophils and to study the involvement of eosinophils in health and disease, we have developed a sensitive and specific enzyme immunoassay. ECP was purified from normal human peripheral blood eosinophils and polyclonal antibodies to ECP...

  9. Homogenous 96-plex PEA immunoassay exhibiting high sensitivity, specificity, and excellent scalability

    DEFF Research Database (Denmark)

    Assarsson, Erika; Lundberg, Martin; Holmquist, Göran

    2014-01-01

    reporters, shown potential to relieve the shortcomings of antibodies and their inherent cross-reactivity in multiplex protein quantification applications. The aim of the present study was to develop a robust 96-plex immunoassay based on the proximity extension assay (PEA) for improved high throughput...... detection of protein biomarkers. This was enabled by: (1) a modified design leading to a reduced number of pipetting steps compared to the existing PEA protocol, as well as improved intra-assay precision; (2) a new enzymatic system that uses a hyper-thermostabile enzyme, Pwo, for uniting the two probes......, such as serum and plasma, and also in xenografted mice and resuspended dried blood spots, consuming only 1 µL sample per test. All-in-all, the development of the current multiplex technique is a step toward robust high throughput protein marker discovery and research....

  10. Production of monoclonal antibodies for sandwich immunoassay detection of ciguatoxin 51-hydroxyCTX3C.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Inoue, Masayuki; Tatami, Atsushi; Miyazaki, Keisuke; Hirama, Masahiro

    2006-09-01

    Every year, more than 50,000 people in subtropical and tropical regions suffer from ciguatera seafood poisoning. The extremely low level of the causative neurotoxins (ciguatoxins) in fish has hampered the preparation of antibodies for detection of the toxins. In this study, we produced a monoclonal antibody (8H4) against the right end of ciguatoxin CTX1B (1) and 51-hydroxyCTX3C (3) by immunizing mice with the keyhole limpet hemocyanin-conjugate of the synthetic HIJKLM ring fragment (10). We used 8H4 and another previously reported monoclonal antibody (10C9) that recognizes the left end of 3 to develop a sandwich enzyme-linked immunosorbent assay (ELISA) to detect 3. The assay could detect 3 down to the ppb level and lacked cross-reactivity with other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, and maitotoxin.

  11. Comparison among performances of a ligase chain reaction-based assay and two enzyme immunoassays in detecting Chlamydia trachomatis in urine specimens from men with nongonococcal urethritis.

    Science.gov (United States)

    Deguchi, T; Yasuda, M; Uno, M; Tada, K; Iwata, H; Komeda, H; Maeda, S; Latila, V; Saito, I; Kawada, Y

    1996-01-01

    We evaluated the performances of a ligase chain reaction (LCR)-based assay and two enzyme immunoassays (Chlamydiazyme and IDEIA) in the detection of Chlamydia trachomatis in urine specimens. We compared the results of testing urine specimens by these assays with those of urethral swab culture by examining samples from 131 men with nongonococcal urethritis. Discrepant results were analyzed by testing urethral swab specimens for C. trachomatis by a PCR-based assay. After the resolution of discrepant results, the sensitivity of urethral swab culture was 85.3%, whereas those of the LCR assay, Chlamydiazyme, and IDEIA with urine specimens were 94.1, 82.4, and 94.1%, respectively. The LCR assay and IDEIA were more sensitive than was urethral swab culture. In addition, the LCR assay, with a sensitivity equal to that of IDEIA, was more specific. Overall, the LCR assay proved to be superior to the enzyme immunoassays in detecting C. trachomatis in urine specimens. Testing urine specimens by LCR assay should be a helpful alternative method for diagnosing C. trachomatis urethral infection in men with nongonococcal urethritis. PMID:8784574

  12. Development and validation of a sensitive enzyme immunoassay (EIA) for blood plasma cortisol in female cattle, buffaloes, and goats.

    Science.gov (United States)

    Yadav, R; Mohan, K; Kumar, V; Sarkar, M; Nitu, K; Meyer, H H D; Prakash, B S

    2013-08-01

    A highly sensitive enzyme immunoassay (EIA) that used the second antibody coating technique and the cortisol-horseradish peroxidase conjugate as a label for determination of free and total cortisol in blood plasma of dairy animals (cows, buffaloes, and goats) was developed. For biological validation of the EIA, blood samples were collected from the animals at 48 and 24 h before and 0, 12, 24, 36, 48, 60, 72, 84, 96, 108, 120, and 132 h after dexamethasone administration. The EIA was performed directly with 20 μL of fresh plasma (for free cortisol) and also with 20 μL of heat-treated plasma (for total cortisol) after 1:5 dilutions with PBS. Cortisol standards ranging from 0.39 to 200 pg/well/20 μL were used, and the sensitivity of the EIA procedure was found to be 0.39 pg/well/20 μL, which corresponded to 0.02 ng/mL. In comparison with RIA the EIA was at least 4 times more sensitive and required 5 times less cortisol antiserum. In female cattle, buffaloes, and goats, the total, free, and bound plasma cortisol before dexamethasone administration was significantly (P < 0.05) higher than the total, free, and bound cortisol after dexamethasone administration. It can be concluded from these studies that the direct, sensitive EIA validated for estimating the free and total cortisol concentrations was sufficiently reliable and quick for studying the dynamics of cortisol distribution in blood plasma of dairy animals. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Photoelectrochemical detection of enzymatically generated CdS nanoparticles: Application to development of immunoassay.

    Science.gov (United States)

    Barroso, Javier; Saa, Laura; Grinyte, Ruta; Pavlov, Valeri

    2016-03-15

    We report an innovative photoelectrochemical process (PEC) based on graphite electrode modified with electroactive polyvinylpyridine bearing osmium complex (Os-PVP). The system relies on the in situ enzymatic generation of CdS quantum dots (QDs). Alkaline phosphatase (ALP) catalyzes the hydrolisis of sodium thiophosphate (TP) to hydrogen sulfide (H2S) which in the presence Cd(2+) ions yields CdS semiconductor nanoparticles (SNPs). Irradiation of SNPs with the standard laboratory UV-illuminator (wavelength of 365 nm) results in photooxidation of 1-thioglycerol (TG) mediated by Os-PVP complex on the surface of graphite electrode at applied potential of 0.31 V vs. Ag/AgCl. A novel immunoassay based on specific enzyme linked immunosorbent assay (ELISA) combined with the PEC methodology was developed. Having selected the affinity interaction between bovine serum albumine (BSA) with anti-BSA antibody (AB) as a model system, we built the PEC immunoassay for AB. The new assay displays a linear range up to 20 ngmL(-1) and a detection limit (DL) of 2 ngmL(-1) (S/N=3) which is lower 5 times that of the traditional chromogenic ELISA test employing p-nitro-phenyl phosphate (pNPP). Copyright © 2015 Elsevier B.V. All rights reserved.

  14. In-electrode vs. on-electrode: ultrasensitive Faraday cage-type electrochemiluminescence immunoassay.

    Science.gov (United States)

    Guo, Zhiyong; Sha, Yuhong; Hu, Yufang; Wang, Sui

    2016-03-28

    A new-concept of an "in-electrode" Faraday cage-type electrochemiluminescence immunoassay (ECLIA) method for the ultrasensitive detection of neurotensin (NT) was reported with capture antibody (Ab1)-nanoFe3O4@graphene (GO) and detector antibody (Ab2)&N-(4-aminobutyl)-N-ethylisoluminol (ABEI)@GO, which led to about 1000-fold improvement in sensitivity by extending the Helmholtz plane (OHP) of the proposed electrode assembly effectively.

  15. Comparison of the performance of five different immunoassays to detect specific antibodies against emerging atypical bovine pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Liu, Lihong

    2013-01-01

    Bovine pestiviruses represent a considerably variable group. In addition to the two accepted species BVDV-1 and BVDV-2, a number of atypical bovine pestiviruses have been detected both in foetal calf sera and in field samples. The sera collected during the initial six weeks of experimental...... infection of calves with atypical pestivirus, BVDV-1 and a combination of both viruses have been examined by routine and new diagnostic tests to validate their robustness and sensitivity. As expected, virus neutralization tests using homologous virus were able to differentiate the two groups infected...... by BVDV-1 or atypical pestivirus, whereas the animals inoculated with a mixture of these two viruses had a reaction pattern very similar to the homologous virus alone. It was found that immunoassays using whole virus and polyclonal antibodies are the most robust, but all tests examined were able to detect...

  16. Stratification of Antibody-Positive Subjects by Antibody Level Reveals an Impact of Immunogenicity on Pharmacokinetics

    OpenAIRE

    Zhou, Lei; Hoofring, Sarah A.; Wu, Yu; Vu, Thuy; Ma, Peiming; Swanson, Steven J.; Chirmule, Narendra; Starcevic, Marta

    2012-01-01

    The availability of highly sensitive immunoassays enables the detection of antidrug antibody (ADA) responses of various concentrations and affinities. The analysis of the impact of antibody status on drug pharmacokinetics (PK) is confounded by the presence of low-affinity or low-concentration antibody responses within the dataset. In a phase 2 clinical trial, a large proportion of subjects (45%) developed ADA following weekly dosing with AMG 317, a fully human monoclonal antibody therapeutic....

  17. An ultra-sensitive monoclonal antibody-based enzyme-linked immunosobent assay for dibutyl phthalate in human urinary

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Lifang [Institute of Pharmacology, Toxicology and Biochemical Pharmaceutics, College of Pharmaceutical Science, Zhejiang University, Hangzhou 310058 (China); Lei, Yajing [Hangzhou EPIE Bio-detection Technology Limited, Hangzhou 310051 (China); Zhang, Dai; Ahmed, Shabbir [Institute of Pharmacology, Toxicology and Biochemical Pharmaceutics, College of Pharmaceutical Science, Zhejiang University, Hangzhou 310058 (China); Chen, Shuqing, E-mail: chenshuqing@zju.edu.cn [Institute of Pharmacology, Toxicology and Biochemical Pharmaceutics, College of Pharmaceutical Science, Zhejiang University, Hangzhou 310058 (China)

    2016-01-15

    tool to detect DBP in urinary samples. - Highlights: • DBP complete antigens (DBP–BSA and DBP–OVA) were designed and synthesized novelty. • The development of DBP monoclonal antibody with no cross-reactivity, low LOD (0.06 ng mL{sup −1}) and IC{sub 50} (7.34 ng mL{sup −1}) • Optimization and evaluation of indirect complete competitive enzyme immunoassay • Application of the method in detecting DBP of internal exposure among Chinese human urinary • Subjects were randomly recruited and system classified by ages, genders and educations.

  18. [In vitro immunization for the production of antibodies to tetanus toxin and toxoid. 1. Systems for the detection of in vitro synthetized specific immunoglobulins. Strategies of test development].

    Science.gov (United States)

    Kiessig, S T; Jahn, S; Porstmann, T; von Baehr, R

    1987-01-01

    By means of semipurified tetanus toxin for solid phase coating in an enzyme immunoassay (ELISA) for detection of specific IgG and IgM antibodies a detection limit of 0.02 IU per litre was achieved. The addition of serum from animals like horses or goats as inert protein to the dilution medium was omitted to prevent a displacement of human antibodies by antitetanus antibodies present in the animals sera. The specificity of the ELISA was demonstrated by inhibition experiments with soluble antigen and in an ELISA for detection of anti-tetanus toxin antibodies from mice immunized with the toxoid from the different purification steps.

  19. Development of a Nanobody-Based Lateral Flow Immunoassay for Detection of Human Norovirus.

    Science.gov (United States)

    Doerflinger, Sylvie Y; Tabatabai, Julia; Schnitzler, Paul; Farah, Carlo; Rameil, Steffen; Sander, Peter; Koromyslova, Anna; Hansman, Grant S

    2016-01-01

    Human noroviruses are the dominant cause of outbreaks of acute gastroenteritis. These viruses are usually detected by molecular methods, including reverse transcriptase PCR (RT-PCR) and enzyme-linked immunosorbent assay (ELISA). Human noroviruses are genetically and antigenically diverse, with two main genogroups that are further subdivided into over 40 different genotypes. During the past decade, genogroup 2 genotype 4 (GII.4) has dominated in most countries, but recently, viruses belonging to GII.17 have increased in prevalence in a number of countries. A number of commercially available ELISAs and lateral flow immunoassays were found to have lower sensitivities to the GII.17 viruses, indicating that the antibodies used in these methods may not have a high level of cross-reactivity. In this study, we developed a rapid Nanobody-based lateral flow immunoassay (Nano-immunochromatography [Nano-IC]) for the detection of human norovirus in clinical specimens. The Nano-IC assay detected virions from two GII.4 norovirus clusters, which included the current dominant strain and a novel variant strain. The Nano-IC method had a sensitivity of 80% and specificity of 86% for outbreak specimens. Norovirus virus-like particles (VLPs) representing four genotypes (GII.4, GII.10, GII.12, and GII.17) could be detected by this method, demonstrating the potential in clinical screening. However, further modifications to the Nano-IC method are needed in order to improve this sensitivity, which may be achieved by the addition of other broadly reactive Nanobodies to the system. IMPORTANCE We previously identified a Nanobody (termed Nano-85) that bound to a highly conserved region on the norovirus capsid. In this study, the Nanobody was biotinylated and gold conjugated for a lateral flow immunoassay (termed Nano-IC). We showed that the Nano-IC assay was capable of detecting at least four antigenically distinct GII genotypes, including the newly emerging GII.17. In the clinical setting, the

  20. Nanogold–polyaniline–nanogold microspheres-functionalized molecular tags for sensitive electrochemical immunoassay of thyroid-stimulating hormone

    International Nuclear Information System (INIS)

    Cui Yuling; Chen Huafeng; Hou Li; Zhang Bing; Liu Bingqian; Chen Guonan; Tang Dianping

    2012-01-01

    Highlights: ► A novel immunosensing strategy was designed for detection of thyroid-stimulating hormone. ► Using nanogold–polyaniline–nanogold microspheres as molecular tags. ► Improvement of electrochemical activity of nanolabels. ► Combination enzyme labels with nanolabels for signal amplification. - Abstract: Methods based on nanomaterial labels have been developed for electrochemical immunosensors and immunoassays, but most involved low sensitivity. Herein a novel class of molecular tags, nanogold–polyaniline–nanogold microspheres (GPGs), was first synthesized and functionalized with horseradish peroxidase-conjugated thyroid-stimulating hormone antibody (HRP-Ab 2 ) for sensitive electrochemical immunoassay of thyroid-stimulating hormone (TSH). X-ray diffraction, confocal Raman spectroscopy, scanning electron microscope and transmission electron microscope were employed to characterize the prepared GPGs. Based on a sandwich-type immunoassay format, the assay was performed in pH 5.0 acetate buffer containing 6.0 mmol L −1 H 2 O 2 by using GPG-labeled HRP-Ab 2 as molecular tags. Compared with pure polyaniline nanospheres and gold nanoparticles alone, the GPG hybrid nanostructures increased the surface area of the nanomaterials, and enhanced the immobilized amount of HRP-Ab 2 . Several labeling protocols comprising HRP-Ab 2 , nanogold particle-labeled HRP-Ab 2 , and polyaniline nanospheres-labeled HRP-Ab 2 , were also investigated for determination of TSH and improved analytical features were obtained by using the GPG-labeled HRP-Ab 2 . With the GPG labeling method, the effects of incubation time and pH of acetate buffer on the current responses of the immunosensors were also studied. The strong attachment of HRP-Ab 2 to the GPGs resulted in a good repeatability and intermediate precision down to 7%. The dynamic concentration range spanned from 0.01 to 20 μIU mL −1 with a detection limit (LOD) of 0.005 μIU mL −1 TSH at the 3s B criterion

  1. Surface modification of polyacrylonitrile fiber for immobilization of antibodies and detection of analyte

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Swati, E-mail: swatijain.iitd@gmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Chattopadhyay, Sruti, E-mail: srutic@hotmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Jackeray, Richa, E-mail: richajackeray.iitd@gmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Singh, Harpal, E-mail: harpal2000@yahoo.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India)

    2009-11-10

    Pendent nitrile groups of multifilamentous polyacrylonitrile (PAN) fibers were reduced to amino groups using lithium aluminum hydride for different time of reduction and amine content was estimated by performing acid-base titrations. Attenuated total reflection-fourier transform infrared spectroscopy (ATR-FTIR) and Differential Scanning Calorimetry (DSC) were used for the characterization of the generated amino groups and thermal properties of the reduced fibers, respectively. The surface morphology of the fibers after reduction and immobilization was characterized using Scanning Electron Microscope (SEM). The newly formed amino groups of the fibers were activated by using glutaraldehyde for the covalent linking of Goat anti-Rabbit IgG-HRP (GAR-HRP) antibody enzyme conjugate. Modified PAN fibers were evaluated as a matrix for sandwich ELISA by using Goat anti-Rabbit antibody (GAR-IgG), Rabbit anti-Goat (RAG-IgG) as analyte and enzyme conjugate GAR-HRP. The fibers reduced for 24 h were able to detect the analyte RAG-IgG at a concentration as low as 3.75 ng mL{sup -1} with 12% skimmed milk as blocking reagent for the optimized concentration of primary antibody GAR-IgG 3 {mu}g mL{sup -1} and peroxidase conjugate GAR-HRP dilution of 8000 fold. The sensitivity, specificity and reproducibility of the developed immunoassay was further established with antibodies present in human blood using Rabbit anti-Human (RAH-IgG) antibody and the corresponding HRP enzyme conjugate. As low as 0.1 {mu}L of human blood was sufficient to perform the assay with the modified fibers.

  2. Role of signal-to-cut-off ratios of anti-hepatitis C virus antibody by enzyme immunoassays along with ID-NAT for screening of whole blood donors in India

    Directory of Open Access Journals (Sweden)

    Satyam Arora

    2016-01-01

    Full Text Available Background: The use of elevated signal-to-cut off ratios (S/CO as an alternate to further supplemental testing (i.e., RIBA has been included in the guidelines provided by the Centres for Disease Control and Prevention for HCV diagnostic purposes since 2003. With availability of screening by NAT and non availability of RIBA, further confirmation of HCV infection has been possible at the molecular level (RNA. Aims: To study the role of S/CO ratios of anti hepatitis C virus antibody detection by enzyme immunoassays (EIA along with ID-NAT for screening of whole blood donors. Methods: In this study we reviewed the donor screening status for anti HCV from January 2013 to May 2014. All the donations were screened for anti HCV with fourth generation ELISA (BioRad Monolisa Ag-Ab Ultra as well as with ID NAT (Procleix Ultrio. The S/CO ratio of all the anti-HCV reactive samples were analysed for their presence of HCV RNA. Results: On screening 21,115 donors for HCV, 83 donors (0.39% were found reactive on pilot tube and repeat plasma bag testing (S/Co ratio ≥1 by ELISA. 41 donors were HCV RNA reactive with ID-NAT. 4 samples out of 41 were NAT yields and 37 were concordant reactive with ELISA. The S/Co ratio of anti-HCV reactive samples ranged from 0.9-11.1 [mean = 5.1; SD ΁ 2.9] whereas S/Co ratio of anti HCV and NAT reactive samples (concordant positives ranged from 4.1-11.1 [mean 7.3]. In our analysis we found that S/CO ratio of 4 showed positive predictive value (PPV and sensitivity of 100%. Summary/Conclusions: Our study showed that S/CO of 4 for anti HCV on ELISA would have maximum positive predictive value of having donor with HCV RNA. S/CO ratio of 4 is very close to 3.8 which was the CDC guideline. The presence of anti-HCV does not distinguish between current or past infections but a confirmed anti-HCV-positive result indicates the need for counseling and medical evaluation for HCV infection.

  3. Giant unilamellar vesicles containing Rhodamine 6G as a marker for immunoassay of bovine serum albumin and lipocalin-2.

    Science.gov (United States)

    Sakamoto, Misato; Shoji, Atsushi; Sugawara, Masao

    2016-07-15

    Functionalized giant unilamellar vesicles (GUVs) containing a fluorescence dye Rhodamine 6G is proposed as a marker in sandwich-type immunoassay for bovine serum albumin (BSA) and lipocalin-2 (LCN2). The GUVs were prepared by the electroformation method and functionalized with anti-BSA antibody and anti-LCN2 antibody, respectively. The purification of antibody-modified GUVs was achieved by conventional centrifugation and a washing step in a flow system. To antigen on an antibody slip, antibody-modified GUVs were added as a marker and incubated. After wash-out of excess reagents and lysis of the bound GUVs with Triton X-100, the fluorescence image was captured. The fluorometric immunoassays for BSA and LCN2 exhibited lower detection limits of 4 and 80 fg ml(-)(1), respectively. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Increasing of sensitivity of fluorescent immunoassay analysis of alpha-fetoprotein by means of plasmonical silver nanoparticles

    International Nuclear Information System (INIS)

    Vashchenko, S.V.; Min'ko, A.A.; Romanenko, A.A.; Gaponenko, S.V.; Kulakovich, O.S.

    2014-01-01

    A test system is proposed based on metal enhanced fluorescence to analyze low concentrations of alpha-fetoprotein (AFP), a tumor marker. Antigen-antibody reaction was performed on polystyrene plates coated with silver nanoparticles to increase sensitivity of fluorescent immunoassay and signal-to-noise ratio as compared to silver-free system. As compared to widely used ELISA technique and other immunoassay techniques the proposed approach is characterized by smaller probe volume, fast analysis and simplicity. The proposed test system uses layer-by-layer assembly approach, LED excitation and nanowatt photodetection set-up. The proposed test system offers AFP detection at concentrations used in clinical practice. Fluorescence enhancement for labeled AFP antibodies on a silver substrate was found to depend on antibodies concentration and was up to 6 times. (authors)

  5. Generation and characterization of chicken egg yolk antibodies against propionibacterium acnes for the prevention of acne vulgaris

    Directory of Open Access Journals (Sweden)

    Karthika Selvan

    2012-01-01

    Full Text Available Introduction: Antigen-specific antibody has been widely used for immunological analysis in the field of diagnosis as well as in pure scientific research, where the IgY antibodies can be raised against P acnes antigen. Material and Methods: To produce IgY against Propionibacterium acnes, laying hens were immunized with P acnes (MTCC No: 1951 and subsequent booster injections were given. The antibodies produced were purified from the egg yolk of immunized chicken using the polyethylene glycol and ammonium sulfate precipitation method and, further, by Diethylaminoethyl (DEAE cellulose ion-exchange column chromatography. The protein fraction of IgY was isolated from the egg yolk. The separation was rapid, and the success of each step was viewed on Sodium Dodecyl Sulphate-polyacrylamide gel electrophoresis (SDS-PAGE. The reactivity of anti-P acnes was evaluated by the Enzyme-linked immunosorbent assay (ELISA test and the dot-immunoassay. Results: With ELISA, the highest titter of 1:10000 was observed on the 150 th day after vaccination. The results of dot-immunoassay suggested that anti-P acnes IgY developed a brown color as positive reaction, which showed the antigen-antibody binding even after a maximum dilution of 1/500. These results suggest that anti-acne IgY was produced and had strong specific antibody reactivity. Conclusion: The findings indicate that anti-acne IgY is worth utilizing as a preventive agent for acne vulgaris.

  6. System-on-fluidics immunoassay device integrating wireless radio-frequency-identification sensor chips.

    Science.gov (United States)

    Yazawa, Yoshiaki; Oonishi, Tadashi; Watanabe, Kazuki; Shiratori, Akiko; Funaoka, Sohei; Fukushima, Masao

    2014-09-01

    A simple and sensitive point-of-care-test (POCT) device for chemiluminescence (CL) immunoassay was devised and tested. The device consists of a plastic flow-channel reactor and two wireless-communication sensor chips, namely, a photo-sensor chip and a temperature-sensor chip. In the flow-channel reactor, a target antigen is captured by an antibody immobilized on the inner wall of the flow-channel and detected with enzyme labeled antibody by using CL substrate. The CL signal corresponding to the amount of antigen is measured by a newly developed radio-frequency-identification (RFID) sensor, which enables batteryless operation and wireless data communication with an external reader. As for the POCT device, its usage environment, especially temperature, varies for each measurement. Hence, temperature compensation is a key issue in regard to eliminating dark-signal fluctuation, which is a major factor in deterioration of the precision of the POCT device. A two-stage temperature-compensation scheme was adopted. As for the first stage, the signals of two photodiodes, one with an open window and one with a sealed window, integrated on the photo-sensor chip are differentiated to delete the dark signal. As for the second stage, the differentiated signal fluctuation caused by a temperature variation is compensated by using the other sensor chip (equipped with a temperature sensor). The dark-level fluctuation caused by temperature was reduced from 0.24 to 0.02 pA/°C. The POCT device was evaluated as a CL immunoassay of thyroid-stimulating hormone (TSH). The flow rate of the CL reagent in the flow channel was optimized. As a result, the detection limit of the POCT device was 0.08 ng/ml (i.e., 0.4 μIU/ml). Copyright © 2014 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  7. An enzyme immunoassay to quantify neurofilament light chain in cerebrospinal fluid.

    NARCIS (Netherlands)

    Geel, W.J.A. van; Rosengren, L.E.; Verbeek, M.M.

    2005-01-01

    Neurofilament light chain is a component of the axonal cytoskeleton. The concentration of the neurofilament light chain in cerebrospinal fluid may reflect axonal damage or the extent of white matter damage. In this study we describe a sensitive immunoassay for the detection of neurofilament light

  8. Deoxynivalenol-mimic nanobody isolated from a naïve phage display nanobody library and its application in immunoassay.

    Science.gov (United States)

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Bhunia, Arun K; Tu, Zhui; Chen, Bo; Liu, Yuan-Yuan

    2015-08-05

    In this study, using mycotoxin deoxynivalenol (DON) as a model hapten, we developed a nanobody-based environmental friendly immunoassay for sensitive detection of DON. Two nanobodies (N-28 and N-31) which bind to anti-DON monoclonal antibody (MAb) were isolated from a naive phage display library. These nanobodies are clonable, thermally stable and mycotoxin-free products and can be served as coating antigen mimetics in heterologous immunoassay. The half inhibition concentration (IC50) of the immunoassay developed with N-28 and N-31 was 8.77 ± 0.41 ng mL(-1) and 19.97 ± 0.84 ng mL(-1), respectively, which were 18- and 8-fold more sensitive than the conventional coating antigen (DON-BSA) based immunoassay. In order to better understand the molecular mechanism of antigen mimicry by nanobody, the 3D structure of "nanobody (N-28) - anti-DON MAb" complex was presented and verified by molecular modeling and alanine-scanning mutagenesis. The results showed that hydrogen bond and hydrophobic interaction formed between Thr 102 - Ser 106 of N-28 and CDR H3 residues of anti-DON antibody may contribute to their binding. This novel concept of enhancing sensitivity of immunoassay for DON based on nanobody may provide potential applications in a general method for immunoassay of various food chemical contaminants. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Evaluation of electrochemiluminescene immunoassay and enzyme-linked immunosorbent assay for serum HBsAb detection

    International Nuclear Information System (INIS)

    Ma Caiyun; Jiang Li; Ge Gaoxia; Zhang Xiaojie

    2005-01-01

    Electrochemiluminescene immunoassay (ECLIA) and enzyme-linked immunosorbent (ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA. The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values, 4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively. The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L. Only in 3 samples, the results measured by ECLIA and ELISA were different (ECLIA: positive; ELISA: negative) among 165 samples. It is concluded that the met hod of ECLIA is more efficient than ELISA for detection of HBsAb in serum. (authors)

  10. A Comparison of Anti-Nuclear Antibody Quantification Using Automated Enzyme Immunoassays and Immunofluorescence Assays

    DEFF Research Database (Denmark)

    Baronaite, Renata; Engelhart, Merete; Mørk Hansen, Troels

    2014-01-01

    using IFA and automated EIA techniques. The IFA results generated by two independent laboratories were compared with the EIA results from antibodies against double-stranded DNA (dsDNA), from ANA screening, and from tests of the seven included subantigens. The final IFA and EIA results for 386 unique......, with Cohen's kappa value of 0.30 (95% confidence interval (CI) = 0.14-0.46), which decreased to 0.23 (95% CI = 0.06-0.40) when the results for dsDNA were omitted. The EIA method was less reliable for assessing nuclear and speckled reactivity patterns, whereas the IFA method presented difficulties detecting...... dsDNA and Ro activity. The automated EIA method was performed in a similar way to the conventional IFA method using HEp-2 cells; thus, automated EIA may be used as a screening test....

  11. Determination of triiodothyronine in serum by enzyme- and radioimmunoassay

    International Nuclear Information System (INIS)

    Oellerich, M.; Haindl, H.; Medizinische Hochschule Hannover

    1981-01-01

    An evaluation of a heterogeneous enzyme immunoassay for determination of triiodothyronine in serum (Enzymun-Test T 3 , Boehringer Mannheim) is presented. The enzyme immunoassay was compared with the laboratory routine radioimmunoassay. The precision of both assays was satisfactory at triiodothyronine concentrations between 1.0 and 8.0 nmol/l (coefficients of variation from day to day 3 from 96-104% and with the radioimmunoassay from 88-111%. A comparison of the results obtained by Enzymun-Test T 3 and the radioimmunoassay in a series of 103 patients showed a good correlation between both methods. L-thyroxine did not cause a relevant cross-reaction in the enzyme immunoassay. About 20 unknown samples can be analyzed in triplicate by Enzymun-Test T 3 within 260 minutes. (orig.) [de

  12. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots

    International Nuclear Information System (INIS)

    Chen, Rui; Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua; Xiong, Yonghua

    2016-01-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H_2O_2) and H_2O_2-sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H_2O_2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H_2O_2, as well as the incubation time between H_2O_2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10"2 CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10"3 CFU/mL to 1.18 × 10"6 CFU/mL were in the range of 65.88%–105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. - Highlights: • A novel fluorescence immunoassay was developed for the ultrasensitive detection of E. coli O157:H7. • This detection was achieved through the combination of the high bioactivity of CAT and H_2O_2-sensitive QDs. • The activity of CAT to H_2O_2 is 1000 folds higher than that of the HRP to tetramethylbenzidine. • The limit of detection of the proposed method could

  13. Production and characterization of monoclonal antibodies specific to the strobilurin pesticide pyraclostrobin.

    Science.gov (United States)

    Mercader, Josep V; Suárez-Pantaleón, Celia; Agulló, Consuelo; Abad-Somovilla, Antonio; Abad-Fuentes, Antonio

    2008-09-10

    Strobilurin fungicides are nowadays among the most important fungicides in the market of active agrochemicals. Pyraclostrobin, which belongs to the last generation of this family of molecules, shows a broader antifungal activity spectrum and higher efficiency and security profiles than previous fungicides. This paper describes the synthesis of functionalized haptens, the production of monoclonal antibodies, and the development of enzyme-linked immunosorbent assays (ELISA) for the detection of pyraclostrobin. A conformational analysis of hapten structure was performed, which provided relevant data concerning the length of the spacer arm. A very useful strategy has been followed for the screening of hybridomas, leading to the selection of a panel of high-affinity monoclonal antibodies to pyraclostrobin. Moreover, different immunoassays have been characterized using the conjugate-coated indirect ELISA format, and limits of detection below 0.1 microg/L have been obtained. Also, a simplified one-step procedure has been carried out with two indirect assays. Finally, these results have been compared with the performance of the same antibodies in the antibody-coated direct ELISA format.

  14. A summary report on the 23rd quality control survey for immunoassays in Japan, 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-10-01

    The purpose of the survey is to improve the quality of in vitro tests and this report is its summary of immunoassays (the old name: RI in vitro tests) conducted in 2001. The survey was performed in 143 facilities out of 1,655 in Japan, which involved 20 national and public university hospitals, 16 private university hospitals, 21 national and public hospitals, 26 private hospitals, 41 hygiene test institutes and 19 reagent manufacturers. Tests examined were on 6 substances related to functions of pituitary, 5 of thyroid, 1 of parathyroid, 4 of gastro-intestine and pancreas, 5 of gonad and placenta, 4 of adrenal, 1 of renal-blood pressure regulation, on IgE, on digoxin and on 12 tumor-related substances. Tests were done on 2-3 samples supplied from the Committee and the mean, standard deviation and coefficient of variation were calculated for one way analysis of variance of within- and between-kit. Methods included those (65.4% vs 62.7% in 2000) with non-radioisotope like enzyme immunoassay (non-RI) and with radioisotopes like radioimmunoassay (RI). Dissociation between manufacturers of non-RI values without a common standard substance and between non-RI and RI values even with the same antibody was noted: the Committee considered these problems as their future task. (K.H.)

  15. Studies on direct and indirect electrochemical immunoassays

    OpenAIRE

    Buckley, Eileen

    1989-01-01

    Two approaches to electrochemical immunoassay are reported. The first approach was an indirect method, involving an electroactive, enzyme-catalysed, substrate to product reaction. Conditions were optimised for the amperometric detection of para-aminophenol, the electroactive product of the alkaline phosphatase catalysed hydrolysis of a new substrate, p-aminophenylphosphate, after separation by HPLC. The second approach involved the direct electrochemical detection of an immunoglo...

  16. A Novel Colorimetric Immunoassay Utilizing the Peroxidase Mimicking Activity of Magnetic Nanoparticles

    Directory of Open Access Journals (Sweden)

    Hyun Gyu Park

    2013-05-01

    Full Text Available A simple colorimetric immunoassay system, based on the peroxidase mimicking activity of Fe3O4 magnetic nanoparticles (MNPs, has been developed to detect clinically important antigenic molecules. MNPs with ca. 10 nm in diameter were synthesized and conjugated with specific antibodies against target molecules, such as rotaviruses and breast cancer cells. Conjugation of the MNPs with antibodies (MNP-Abs enabled specific recognition of the corresponding target antigenic molecules through the generation of color signals arising from the colorimetric reaction between the selected peroxidase substrate, 3,3',5,5'-tetramethylbenzidine (TMB and H2O2. Based on the MNP-promoted colorimetric reaction, the target molecules were detected and quantified by measuring absorbance intensities corresponding to the oxidized form of TMB. Owing to the higher stabilities and economic feasibilities of MNPs as compared to horseradish peroxidase (HRP, the new colorimetric system employing MNP-Abs has the potential of serving as a potent immunoassay that should substitute for conventional HRP-based immunoassays. The strategy employed to develop the new methodology has the potential of being extended to the construction of simple diagnostic systems for a variety of biomolecules related to human cancers and infectious diseases, particularly in the realm of point-of-care applications.

  17. Bluetongue virus: comparative evaluation of enzyme-linked immunosorbent assay, immunodiffusion, and serum neutralization for detection of viral antibodies.

    OpenAIRE

    Poli, G; Stott, J; Liu, Y S; Manning, J S

    1982-01-01

    Comparative studies on the detection of bovine serum immunoglobulin G antibodies to bluetongue virus with an enzyme-linked immunosorbent assay, an immunodiffusion method, and a serum neutralization assay demonstrated complete concordance between the enzyme-linked immunosorbent assay and the serum neutralization assay results. However, the immunodiffusion method failed to detect bluetongue virus antibody in a substantial number of sera found to possess bluetongue virus immunoglobulin G with th...

  18. Elevated serum antiphospholipid antibodies in adults with celiac disease.

    Science.gov (United States)

    Laine, Outi; Pitkänen, Katariina; Lindfors, Katri; Huhtala, Heini; Niemelä, Onni; Collin, Pekka; Kurppa, Kalle; Kaukinen, Katri

    2018-05-01

    An increased incidence of thrombosis is suggested in celiac disease. We explored serum levels of antiphospholipid antibodies in untreated and treated adult celiac disease patients. A cohort of 179 biopsy-proven celiac disease patients (89 untreated, 90 on long-term gluten-free diet) and 91 non-celiac controls underwent clinical examination, assessment of celiac serology and enzyme immunoassay testing for anticardiolipin IgG and IgM, prothrombin IgG, and phosphatidylserine-prothrombin IgG and IgM. The level of antiphospholipid antibodies was higher in celiac disease patients compared with controls: anticardiolipin IgG 4.9 (0.7-33.8) vs 2.2 (0.4-9.6) U/ml, antiprothrombin IgG 2.9 (0.3-87.8) vs 2.1 (0.5-187.0) U/ml, antiphosphatidylserine-prothrombin IgG 6.9 (0.0-54.1) vs 2.3 (0.5-15.1) U/ml; p celiac disease at presentation (gastrointestinal symptoms, malabsorption or anemia, and extraintestinal symptoms or screen-detected disease) had no effect on the level of serum antiphospholipid antibodies. The serum level of antiphospholipid antibodies is increased in adults with celiac disease. The higher level of antibodies in treated patients suggests that the increase is not gluten-dependent. The prothrombotic role of antiphospholipid antibodies in celiac disease warrants further studies. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  19. Monoclonal antibodies: an overview of their advantages and limitations in nuclear medicine

    International Nuclear Information System (INIS)

    Revillard, J.P.; Cohen, J.

    1982-01-01

    The following topics were reviewed: antigen recognition by the immune system; development of immunoassays for antigenic components of biological fluids; monoclonal antibodies against infectious agents; monochonal antibodies against tumor and differentiation antigens; human monoclonal antibodies

  20. Radiolabelling of glycosylated MFE-23::CPG2 fusion protein (MFECP1) with 99mTc for quantitation of tumour antibody-enzyme localisation in antibody-directed enzyme pro-drug therapy (ADEPT).

    Science.gov (United States)

    Francis, R J; Mather, S J; Chester, K; Sharma, S K; Bhatia, J; Pedley, R B; Waibel, R; Green, A J; Begent, R H J

    2004-08-01

    MFECP1 is a glycosylated recombinant fusion protein composed of MFE-23, a high-affinity anti-carcinoembryonic antigen (CEA) single chain Fv (scFv), fused to the enzyme carboxypeptidase G2 (CPG2), and has been constructed for use in antibody-directed enzyme pro-drug therapy (ADEPT). Radiolabelling of glycosylated MFECP1 with technetium-99m was developed for the purpose of determining tumour localisation of MFECP1 in a phase I ADEPT clinical study. The method used was 99mTc-carbonyl [99mTc(H2O)3(CO)3]+ (abbreviated to TcCO) mediated labelling of 99mTc to the hexahistidine (His) tag of MFECP1. MFECP1 fusion protein was labelled with TcCO under a variety of conditions, and this was shown to be a relatively simple and robust method. Tissue biodistribution was assessed in a CEA-expressing LS174T (human colon carcinoma) nude mouse xenograft model. Tissues were taken at 1, 4 and 6 h for assessment of distribution of radioactivity and for measurement of CPG2 enzyme levels. The amount of radioactivity retained by the tumour proved to be an accurate estimation of actual measured enzyme activity, indicating that this radiolabelling method does not appear to damage the antibody-antigen binding or the enzyme activity of MFECP1. However, correlation between CPG2 enzyme activity and measured radioactivity in liver, spleen and kidney was poor, indicating retention of radioactivity in non-tumour sites but loss of enzyme activity. The high retention of technetium radioisotope in normal tissues may limit the clinical applicability of this radiolabelling method for MFECP1; however, these results suggest that this technique does have applicability for measuring the biodistribution of His-tagged recombinant proteins.

  1. Radiolabelling of glycosylated MFE-23::CPG2 fusion protein (MFECP1) with 99mTc for quantitation of tumour antibody-enzyme localisation in antibody-directed enzyme pro-drug therapy (ADEPT)

    International Nuclear Information System (INIS)

    Francis, R.J.; Chester, K.; Sharma, S.K.; Bhatia, J.; Pedley, R.B.; Green, A.J.; Begent, R.H.J.; Mather, S.J.; Waibel, R.

    2004-01-01

    MFECP1 is a glycosylated recombinant fusion protein composed of MFE-23, a high-affinity anti-carcinoembryonic antigen (CEA) single chain Fv (scFv), fused to the enzyme carboxypeptidase G2 (CPG2), and has been constructed for use in antibody-directed enzyme pro-drug therapy (ADEPT). Radiolabelling of glycosylated MFECP1 with technetium-99m was developed for the purpose of determining tumour localisation of MFECP1 in a phase I ADEPT clinical study. The method used was 99m Tc-carbonyl [ 99m Tc(H 2 O) 3 (CO) 3 ] + (abbreviated to TcCO) mediated labelling of 99m Tc to the hexahistidine (His) tag of MFECP1. MFECP1 fusion protein was labelled with TcCO under a variety of conditions, and this was shown to be a relatively simple and robust method. Tissue biodistribution was assessed in a CEA-expressing LS174T (human colon carcinoma) nude mouse xenograft model. Tissues were taken at 1, 4 and 6 h for assessment of distribution of radioactivity and for measurement of CPG2 enzyme levels. The amount of radioactivity retained by the tumour proved to be an accurate estimation of actual measured enzyme activity, indicating that this radiolabelling method does not appear to damage the antibody-antigen binding or the enzyme activity of MFECP1. However, correlation between CPG2 enzyme activity and measured radioactivity in liver, spleen and kidney was poor, indicating retention of radioactivity in non-tumour sites but loss of enzyme activity. The high retention of technetium radioisotope in normal tissues may limit the clinical applicability of this radiolabelling method for MFECP1; however, these results suggest that this technique does have applicability for measuring the biodistribution of His-tagged recombinant proteins. (orig.)

  2. Optimization of AFP-radioimmunoassay using Antibody Capture Technique

    International Nuclear Information System (INIS)

    Moustafa, K.A.

    2003-01-01

    Alpha-fetoprotein (AFP) is a substance produced by the unborn baby. When the neural tube is not properly formed large amounts of AFP pass into the amniotic fluid and reach the mother's blood. By measuring AFP in the mother's blood and amniotic fluid, it is possible to tell whether or not there is a chance that the unborn baby has a neural tube defect. AFP also used as a tumor marker for hepatocellular carcinoma. There are many different techniques for measuring AFP in blood, but the most accurate one is the immunoassay technique. The immunoassays can be classified on the basis of methodology into three classes; (1) the antibody capture assays, (2) the antigen capture assay, (3)the two-antibody sandwich assays. In this present study, the antibody capture assay in which the antigen is attached to a solid support, and labeled antibody is allowed to bind, will be optimized

  3. An enzyme-linked immuno-filtration assay used to compare infant and maternal antibody profiles in toxoplasmosis.

    Science.gov (United States)

    Pinon, J M; Thoannes, H; Gruson, N

    1985-02-28

    Enzyme-linked immuno-filtration assay is carried out on a micropore membrane. This doubly analytical technique permits simultaneous study of antibody specificity by immunoprecipitation and characterisation of antibody isotypes by immuno-filtration with enzyme-labelled antibodies. Recognition of the same T. gondii antigenic constituent by IgG, IgA, IgM or IgE antibodies produces couplets (IgG-IgM; IgG-IgA) or triplets (IgG-IgM-IgA; IgG-IgM-IgE) which identify the functional fractions of the toxoplasmosis antigen. In acquired toxoplasmosis, the persistence of IgM antibody long after infestation puts in question the implication of recent infestation normally linked to detection of this isotype. For sera of comparable titres, comparison of immunological profiles by the method described demonstrates disparities in the composition of the specific antibody content as expressed in international units. Use of the same method to detect IgM antibodies or distinguish between transmitted maternal IgG and IgG antibodies synthesised by the foetus or neonate makes a diagnosis of congenital toxoplasmosis possible in 85% of cases during the first few days of life. With the method described the diagnosis may be made on average 5 months earlier than with classical techniques. In the course of surveillance for latent congenital toxoplasmosis, the appearance of IgM or IgE antibodies raises the possibility of complications (hydrocephalus, chorioretinitis). After cessation of treatment, a rise in IgG antibodies indicating persistence of infection is detected earlier by the present than by classical methods.

  4. Enzyme immunoassay for the detection of porcine gelatine in edible bird's nests.

    Science.gov (United States)

    Tukiran, Nur Azira; Ismail, Amin; Mustafa, Shuhaimi; Hamid, Muhajir

    2015-01-01

    Porcine gelatine is a common adulterant found in edible bird's nests (EBNs) used to increase the net weight prior to sale. This study aimed to develop indirect enzyme-linked immunosorbent assays (ELISAs) for porcine gelatine adulteration using anti-peptide polyclonal antibodies. Three indirect ELISAs were developed (PAB1, 2 and 3), which had limits of detection (LODs) of 0.12, 0.10 and 0.11 µg g(-1), respectively. When applied to standard solutions of porcine gelatine, the inter- and intra-assays showed coefficients of variation (CVs) less than 20% and were able to detect at least 0.5 ng µg(-1) (0.05%) porcine gelatine in spiked samples. The proposed ELISA offers attractions for quality control in the EBN industry.

  5. Single biosensor immunoassay for the detection of five aminoglycosides in reconstituted skimmed milk

    NARCIS (Netherlands)

    Haasnoot, W.; Cazemier, G.; Koets, M.; Amerongen, van A.

    2003-01-01

    The application of an optical biosensor (Biacore 3000), with four flow channels (Fcs), in combination with a mixture of four specific antibodies resulted in a competitive inhibition biosensor immunoassay (BIA) for the simultaneous detection of the five relevant aminoglycosides in reconstituted

  6. [Detecting the markers of HIV infection with the new enzyme immunoassay diagnostic kit "DS-EIA-HIV-AB-AG-SPECTRUM" at the laboratories of AIDS prevention and control centers in the Volga Federal District].

    Science.gov (United States)

    Ivanova, N I; Peksheva, O Iu

    2009-03-01

    A possibility of simultaneously detecting specific antibodies to HIV-1 and HIV-2 by enzyme immunoassay (EIA) at lower concentrations than those by immunoblotting (IB), and well as an additional possibility of earlier diagnosis of HIV infection, by identifying the HIV-1 antigen p24 lay the foundation of the "DS-EIA-HIV-AB-AG-SPECTRUM" test system made by OOO "Research-and-Production Association "Diagnosticheskiye Sistemy" (Diagnostic Systems). These peculiarities were compared with those of IB at a number of laboratories of AIDS prevention and control centers in the Volga Federal District, by using native serum/plasma samples and a specially designed control panel. The analysis of the conducted studies to identify HIV-1 and HIV-2 antibodies and HIV-1 antigen p24 in 65 plasma/serum samples in the "DS-EIA-HIV-AB-AG-SPECTRUM" and "LIA-HIV-1/2" (OOO "Niarmedik plus") test systems while confirming the positive result indicated agreement in 57 (87.7%) cases. The diagnostic possibilities of the "DS-EIA-HIV-AB-AG-SPECTRUM" test system versus the "New Lav-Blot I" one to make a laboratory diagnosis of HIV infection were studied. Irrefragable answers as to the availability of HIV-1 markers in the study serum samples on the enciphered panel were provided by IB in 73.3% of cases and EIA in 92%.

  7. Effect of serum heat-inactivation and dilution on detection of anti-WNV antibodies in mice by West Nile virus E-protein microsphere immunoassay.

    Directory of Open Access Journals (Sweden)

    Madhuri Namekar

    Full Text Available Immunopathogenesis studies employing West Nile virus (WNV mice model are important for the development of antivirals and vaccines against WNV. Since antibodies produced in mice early during WNV infection are essential for clearing virus from the periphery, it is important to detect early and persistent anti-WNV antibodies. ELISA and plaque reduction neutralization tests are traditionally used for detection of anti-WNV antibodies and WNV-neutralizing antibodies, respectively. Although these assays are sensitive and specific, they are expensive and time consuming. Microsphere immunoassays (MIA are sensitive, specific, allow for high throughput, are cost effective, require less time to perform than other methods, and require low serum volumes. Several assay parameters such as serum heat-inactivation (HI and dilution can alter WNV MIA sensitivity. We examined the effect of these parameters on WNV E-protein MIA (WNV E-MIA for the enhanced detection of anti-WNV IgM and IgG antibodies. WNV E-MIA was conducted using serial dilutions of HI and non-HI (NHI serum collected at various time points from mice inoculated with WNV. HI significantly enhanced detection of IgM and IgG antibodies as compared to NHI serum. WNV IgM and IgG antibodies in HI sera were detected earlier at day 3 and IgM antibodies persisted up to day 24 after infection. HI serum at 1∶20 dilution was found to be optimal for detection of both IgM and IgG antibodies as compared to higher-serum dilutions. Further, addition of exogenous complement to the HI serum decreased the WNV E-MIA sensitivity. These results suggest that serum-HI and optimal dilution enhance WNV E-MIA sensitivity by eliminating the complement interference, thereby detecting low-titer anti-WNV antibodies during early and late phases of infection. This improved MIA can also be readily employed for detection of low-titer antibodies for detection of other infectious agents and host proteins.

  8. A study on the relationship of anti-HCV antibody and hepatitis C viremia in post-transfusion hepatitis

    International Nuclear Information System (INIS)

    Lee, Dong Soon

    1993-01-01

    The specimens of blood transfusion recipients who recieved the Anti-HCV antibody positive bloods were analyzed at irregular intervals by enzyme immunoassay to measure the anti-HCV antibody and reverse transcription PCR of hepatitis C virus to evaluate the viremic states. At the same time, the specimens of anti-HCV antibody positive healthy blood donors are analyzed by the reverse transcription PCR method. We analyzed the 9 cases of anti-HCV positive blood donors by reverse transcription PCR and no cases of positive HCV reverse transcription PCR is found. The 5 patients who recieved the anti-HCV positive blood by blood transfusion was followed at irregular interval. Of 5 blood recipients, Hepatitis C virus was detected in 2 patients (40%) and Anti-HCV antibody was detected in 2 patients (40%). We suppose that in contrast to disease group (Non A non B hepatitis), the possibility of viremia in the anti-HCV positive blood donors is significantly low and the character of those antibody may be convalescent antibody after hepatitis C resolution. (Author)

  9. A study on the relationship of anti-HCV antibody and hepatitis C viremia in post-transfusion hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Soon [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1993-01-01

    The specimens of blood transfusion recipients who recieved the Anti-HCV antibody positive bloods were analyzed at irregular intervals by enzyme immunoassay to measure the anti-HCV antibody and reverse transcription PCR of hepatitis C virus to evaluate the viremic states. At the same time, the specimens of anti-HCV antibody positive healthy blood donors are analyzed by the reverse transcription PCR method. We analyzed the 9 cases of anti-HCV positive blood donors by reverse transcription PCR and no cases of positive HCV reverse transcription PCR is found. The 5 patients who recieved the anti-HCV positive blood by blood transfusion was followed at irregular interval. Of 5 blood recipients, Hepatitis C virus was detected in 2 patients (40%) and Anti-HCV antibody was detected in 2 patients (40%). We suppose that in contrast to disease group (Non A non B hepatitis), the possibility of viremia in the anti-HCV positive blood donors is significantly low and the character of those antibody may be convalescent antibody after hepatitis C resolution. (Author).

  10. Comparison of enzyme-linked immunosorbent assay and rapid chemiluminescent analyser in the detection of myeloperoxidase and proteinase 3 autoantibodies.

    Science.gov (United States)

    Pucar, Phillippa A; Hawkins, Carolyn A; Randall, Katrina L; Li, Candice; McNaughton, Euan; Cook, Matthew C

    2017-06-01

    Antibodies to myeloperoxidase (MPO) and proteinase 3 (PR3) are vital in the diagnosis and management of ANCA-associated vasculitis. A chemiluminescent immunoassay (CLIA; Quanta Flash) provides MPO and PR3 antibody results in 30 minutes, which is much faster than enzyme-linked immunosorbent assay (ELISA). We compared the performance of ELISA (Orgentec) and CLIA (Quanta Flash) for MPO and PR3 antibody quantitation on 303 samples, comprising 196 consecutive samples received in a single diagnostic laboratory over a 3 month period, and 107 samples collected from 42 known vasculitis patients over a 40 month period. We observed a correlation between both methods using spearman correlation coefficients (MPO, r s  = 0.63, p assays) and disease relapse (correlation for both MPO and PR3 antibody quantitation r s  = 0.84, p = 0.03 and r s  = 0.78, p ELISA for measurement of MPO and PR3 antibodies. Copyright © 2017. Published by Elsevier B.V.

  11. Descripción de un inmunoensayo enzimático que reconoce anticuerpos anti-factor VIII/von Willebrand obtenidos a partir de hibridomas múridos Description of an enzime immunoassay that recognizes anti-factor VIII/von Willebrand antibodies obtained from murine hybridomas

    Directory of Open Access Journals (Sweden)

    Renée González Sampedro

    1999-04-01

    Full Text Available Se describe un inmunoensayo enzimático (ELISA que detecta anticuerpos anti-Factor-VIII/von Willebrand (FVIII/vW, con una relación de enlace > 5, que permite reconocer dichos anticuerpos tempranamente en los cultivos de hibridomas múridos. Para la adsorción de las placas del inmunoensayo se utilizaron preparados semipurificados de FVIII/vW obtenidos en Cuba. Se inmunizaron ratones Balb/c con la finalidad de generar los anticuerpos monoclonales detectados por este ELISA. Se obtuvo un clon con crecimiento estable y varios subclones positivos por el ELISA con actividad biológica específica de anticuerpos inhibidores de FVIIIAn enzime immunoassay (ELISA that detects anti-Factor VIII/von Willebrand (FVIII/vw antibodies with a binding relationship > 5 that allows the early recognition of such antibodies in the cultures of murine hybridomas is described. Semipurified preparations of FVIII/vw obtained in Cuba were used for the adsorption of the immunoassay plates. Balb/c mice were immunized in order to generate the monoclonal antibodies detected by this ELISA. A clone with stable growth and several positive subclones were obtained by ELISA with specific biological activity of FVIII-inhibiting antibodies

  12. Detection of phase I IgG antibodies to Coxiella burnetii with EIA as a screening test for blood donations.

    Science.gov (United States)

    van der Hoek, W; Wielders, C C H; Schimmer, B; Wegdam-Blans, M C A; Meekelenkamp, J; Zaaijer, H L; Schneeberger, P M

    2012-11-01

    The presence of a high phase I IgG antibody titre may indicate chronic infection and a risk for the transmission of Coxiella burnetii through blood transfusion. The outbreak of Q fever in the Netherlands allowed for the comparison of an enzyme immunoassay (EIA) with the reference immunofluorescence assay (IFA) in a large group of individuals one year after acute Q fever. EIA is 100 % sensitive in detecting high (≥1:1,024) phase I IgG antibody titres. The cost of screening with EIA and confirming all EIA-positive results with IFA is much lower than screening all donations with IFA. This should be taken into account in cost-effectiveness analyses of screening programmes.

  13. Rapid enzyme-linked immunosorbent assay (ELISA) for Aspergillus fumigatus antibodies.

    OpenAIRE

    Richardson, M D; Stubbins, J M; Warnock, D W

    1982-01-01

    A rapid enzyme-linked immunosorbent assay (ELISA) where component incubation periods were shortened to one hour, was compared with agar gel double diffusion (AGDD) and a standard ELISA procedure for detecting antibodies to Aspergillus fumigatus in 28 asthmatic patients with suspected allergic aspergillosis. Using two A fumigatus antigens the rapid ELISA compared well with AGDD and the standard ELISA method. Eleven sera that reacted with both antigens in AGDD were all positive against antigen ...

  14. Challenges in Developing a Biochip for Intact Histamine Using Commercial Antibodies

    Directory of Open Access Journals (Sweden)

    Leena Mattsson

    2017-12-01

    Full Text Available This study describes the development and the challenges in the development of an on-chip immunoassay for histamine using commercially available antibodies. Histamine can be used as an indicator of food freshness and quality, but it is also a relevant marker in clinical diagnostics. Due to its low molecular weight, simple structure and thus low immunogenicity production of high specificity and affinity antibodies is difficult. From six commercial anti-histamine antibodies tested, only two bound the histamine free in the solution. A fluorescent on-chip immunoassay for histamine was established with a dynamic range of 8–111 µg/mL using polyclonal anti-histamine antibody H7403 from Sigma (Mendota Heights, MN, USA. The anti-histamine antibodies described and used in published literature are thoroughly reviewed and the quality of commercial antibodies and their traceability and quality issues are highlighted and extensively discussed.

  15. Development of Immunoassay Based on Monoclonal Antibody Reacted with the Neonicotinoid Insecticides Clothianidin and Dinotefuran

    Directory of Open Access Journals (Sweden)

    Seiji Iwasa

    2012-11-01

    Full Text Available Enzyme-linked immunosorbent assay (ELISA based on a monoclonal antibody (MoAb was developed for the neonicotinoid insecticide clothianidin. A new clothianidin hapten (3-[5-(3-methyl-2-nitroguanidinomethyl-1,3-thiazol-2-ylthio] propionic acid was synthesized and conjugated to keyhole limpet hemocyanin, and was used for monoclonal antibody preparation. The resulting MoAb CTN-16A3-13 was characterized by a direct competitive ELISA (dc-ELISA. The 50% of inhibition concentration value with clothianidin was 4.4 ng/mL, and the working range was 1.5–15 ng/mL. The antibody showed high cross-reactivity (64% to dinotefuran among the structurally related neonicotinoid insecticides. The recovery examinations of clothianidin for cucumber, tomato and apple showed highly agreement with the spiked concentrations; the recovery rate was between 104% and 124% and the coefficient of variation value was between 1.8% and 15%. Although the recovery rate of the dc-ELISA was slightly higher than that of HPLC analysis, the difference was small enough to accept the dc-ELISA as a useful method for residue analysis of clothianidin in garden crops.

  16. Development of immunoassay based on monoclonal antibody reacted with the neonicotinoid insecticides clothianidin and dinotefuran.

    Science.gov (United States)

    Uchigashima, Mikiko; Watanabe, Eiki; Ito, Shigekazu; Iwasa, Seiji; Miyake, Shiro

    2012-11-15

    Enzyme-linked immunosorbent assay (ELISA) based on a monoclonal antibody (MoAb) was developed for the neonicotinoid insecticide clothianidin. A new clothianidin hapten (3-[5-(3-methyl-2-nitroguanidinomethyl)-1,3-thiazol-2-ylthio] propionic acid) was synthesized and conjugated to keyhole limpet hemocyanin, and was used for monoclonal antibody preparation. The resulting MoAb CTN-16A3-13 was characterized by a direct competitive ELISA (dc-ELISA). The 50% of inhibition concentration value with clothianidin was 4.4 ng/mL, and the working range was 1.5–15 ng/mL. The antibody showed high cross-reactivity (64%) to dinotefuran among the structurally related neonicotinoid insecticides. The recovery examinations of clothianidin for cucumber, tomato and apple showed highly agreement with the spiked concentrations; the recovery rate was between 104% and 124% and the coefficient of variation value was between 1.8% and 15%. Although the recovery rate of the dc-ELISA was slightly higher than that of HPLC analysis, the difference was small enough to accept the dc-ELISA as a useful method for residue analysis of clothianidin in garden crops.

  17. A review of promising new immunoassay technology for monitoring forest herbicides

    Science.gov (United States)

    Charles K. McMahon

    1993-01-01

    Rising costs of classical instrumental methods of chemical analysis coupled with an increasing need for environmental monitoring has lead to the development of highly sensitive, low-cost immunochemical methods of analysis for the detection of environmental contaminants. These methods known simply as immunoassays are chemical assays which use antibodies as reagents. A...

  18. Development of an Enzyme Linked Immunosorbent Assay to Detect Chicken Parvovirus Specific Antibodies

    Science.gov (United States)

    Here we report the development and application of an enzyme linked immunosorbent assay to detect parvovirus-specific antibodies in chicken sera. We used an approach previously described for other parvoviruses to clone and express viral structural proteins in insect cells from recombinant baculovirus...

  19. Monoclonal antibodies against human angiotensinogen, their characterization and use in an angiotensinogen enzyme linked immunosorbent assay.

    Science.gov (United States)

    Rubin, I; Lykkegaard, S; Olsen, A A; Selmer, J; Ballegaard, M

    1988-01-01

    Monoclonal antibodies were produced against human angiotensinogen. An enzyme linked immunosorbent assay (ELISA) was developed using a high affinity monoclonal antibody as catching antibody and a polyclonal rabbit anti human angiotensinogen antibody as detecting antibody in a "sandwich" ELISA. Linear range of the ELISA was 15-450 pmol/l of human angiotensinogen. Intra- and inter- assay variation coefficients were in the range of 2% to 8%. A correlation coefficient, r = 0.97, (n = 20), with values obtained by radioimmunoassay. This correlation coefficient, obtained by using both normal and pregnant sera, confirmed that the ELISA fulfill the requirements for clinical useful assay. Characterization of the antibodies were performed with respect to affinity constant and epitopes.

  20. An efficient enzyme immunoassay for glutamate using glutaraldehyde coupling of the hapten to microtiter plates.

    Science.gov (United States)

    Ordronneau, P; Abdullah, L H; Petrusz, P

    1991-09-13

    In order to coat microtiter plates for enzyme immunoassays (EIAs), amino acids and other haptens are usually coupled to larger protein molecules. The formation of such conjugates is not always reproducible. This may lead to inconsistent hapten-protein stoichiometries, unfavorable orientation of the hapten on the protein and/or well-to-well variation in the concentration of the available hapten. In the assay described here the excitatory amino acid (EAA) Glu is coupled directly to polystyrene microtiter wells with GA. Each step of the assay was tested for maximum efficiency. The resulting EIA with Glu as a competitor gave excellent reproducibility (coefficient of variation = 5.87%), an EC50 of 2.02 X 10(-5) M and a detection limit of 1.26 X 10(-6) M. This EIA method is generally useful for a variety of antisera to amino acids and small peptides and a wide range of competing substances. It can be used to characterize the conformational requirements for antigen binding, to assay for glutamate or to identify compounds with glutamate-like structure in unknown solutions.

  1. A murine monoclonal antibody based enzyme-linked immunosorbent assay for almond (Prunus dulcis L.) detection.

    Science.gov (United States)

    Su, Mengna; Venkatachalam, Mahesh; Liu, Changqi; Zhang, Ying; Roux, Kenneth H; Sathe, Shridhar K

    2013-11-13

    A sandwich enzyme-linked immunosorbent assay (ELISA) using anti-almond soluble protein rabbit polyclonal antibodies as capture antibodies and murine monoclonal antibody 4C10 as the detection antibodies was developed. The assay is specific and sensitive (3-200 ng almond protein/mL) for almond detection. The standardized assay is accurate (assay variability assay did not register any cross-reactivity with the tested food matrices, suggesting the assay to be almond amandin specific. The assay could detect the presence of declared almond in the tested matched commercial samples. Further, the assay reliably detected the presence of almonds in the laboratory prepared food samples spiked with almond flour.

  2. A dual amplified electrochemical immunosensor for ofloxacin: Polypyrrole film-Au nanocluster as the matrix and multi-enzyme-antibody functionalized gold nanorod as the label

    International Nuclear Information System (INIS)

    Zang, Shuai; Liu, Yingju; Lin, Mouhong; Kang, Jianli; Sun, Yuanming; Lei, Hongtao

    2013-01-01

    Graphical abstract: Schematic representation of the OFL electrochemical immunosensor using Au nanoclusters/PPy/GCE as the substrate and multi-HRP-GNR-Ab2 bioconjugates as the label. Highlights: ► Gold nanorod was used to load HRP and Ab 2 to form multi-HRP-GNR-Ab 2 . ► A sensitive immunosensor for ofloxacin was constructed using the homemade antibody. ► A dual signal amplified strategy was based on the PPy-Au and multi-HRP-GNR-Ab 2 . -- Abstract: In this work, an electrochemical immunosensor, basing on a dual signal amplified strategy by employing a biocompatible polypyrrole film-Au nanocluster matrix as a sensor platform and multi-enzyme-antibody functionalized gold nanorod as an electrochemical detection label, is established for sensitive detection of ofloxacin (OFL). Firstly, polypyrrole film and Au nanoclusters were progressively fabricated onto the surface of a glassy carbon electrode via electropolymerization and electrochemical deposition, respectively. Such PPy-Au nanocomposite modified electrode was used to immobilize OFL-OVA, blocked with the blocking reagent, and then associated with the corresponding antibody. Secondly, gold nanorod (GNR) was synthesized to load horseradish peroxidase (HRP) and horseradish peroxidase-secondary antibody (HRP-Ab 2 ), and the resulting nanostructure (multi-HRP-GNR-Ab 2 ) was applied as the detection label. The fabrication process of the ordered multilayer structure and immunosensor were characterized by scanning electron microscopy (SEM) and electrochemical measurements, respectively. Finally, based on a competitive immunoassay, i.e., the association ability with the corresponding antibody between the captured antigen and free OFL in the solution, the fabricated immunosensor exhibited a sensitive response to OFL in the range from 0.08 to 410 ng/mL with a detection limit of 0.03 ng/mL. The current immunosensor exhibited good sensitivity, selectivity and long-term stability. This amplification strategy shows excellent

  3. Silver nanoparticles deposited on graphene oxide for ultrasensitive surface-enhanced Raman scattering immunoassay of cancer biomarker.

    Science.gov (United States)

    Yang, Lin; Zhen, Shu Jun; Li, Yuan Fang; Huang, Cheng Zhi

    2018-06-14

    Graphene oxide (GO) exhibits distinctive Raman scattering features for its high frequency D (disordered) and tangential modes (G-band), which are characteristically sharp at 1580 cm-1 and 1350 cm-1, respectively, but are too weak for sensitive quantitation purposes. By depositing silver nanoparticles on the surface of GO in this contribution, both D and G bands of GO become enhanced. The enzyme label of this method controls the dissolution of silver nanoparticles on the surface of GO through hydrogen peroxide which is produced by the oxidation of the enzyme substrate. With the dissolution of the silver nanoparticles a greatly decreased SERS signal of GO was obtained. This strategy involves dual signal amplification of the enzyme and nanocomposites to improve the detection sensitivity. As a proof of concept, prostate specific antigen (PSA), a biomarker for prostate cancer, is successfully detected as a target by forming a sandwich structure in immunoassay. The SERS immunoassay possesses excellent analytical performance in the range 0.5 pg mL-1 to 500 pg mL-1 with a limit of detection of 0.23 pg mL-1, making the detection of PSA serum samples from prostate cancer patients satisfactory, demonstrating that the sensitive enzyme-assisted dissolved AgNPs SERS immunoassay of PSA has potential applications in clinical diagnosis.

  4. Screening for cocaine on Euro banknotes by a highly sensitive enzyme immunoassay.

    Science.gov (United States)

    Abdelshafi, Nahla A; Panne, Ulrich; Schneider, Rudolf J

    2017-04-01

    This study focused on quantitative detection of cocaine on Euro banknotes in Germany. A sensitive direct competitive immunoassay was developed and optimized with a limit of detection (LOD) of 5.6ng/L. Exhaustive cocaine extraction by solvent was tested using different methanol concentrations and buffered solutions. Cross-reactivity studies were performed to determine the degree of interference of cocaine metabolites with the immunoassay. Sixty-five Euro banknotes obtained from different districts in Berlin were evaluated. A 100% contamination frequency with cocaine was detected. A comparison between the amount of cocaine extracted by cotton swabbing of one square centimeter of the banknote showed a good correlation for lower contamination levels. This assay showed high sensitivity of detecting pg of cocaine per 1cm 2 of one banknote by swabbing 1cm 2 : 0, 14, and 21pg/cm 2 . Moreover, three notes of different denominations revealed high cocaine concentration; 1.1mg/note, and twice 55µg/note. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Selective cytotoxicity of an oxygen-radical-generating enzyme conjugated to a monoclonal antibody.

    Science.gov (United States)

    Battelli, M G; Abbondanza, A; Tazzari, P L; Dinota, A; Rizzi, S; Grassi, G; Gobbi, M; Stirpe, F

    1988-07-01

    The monoclonal antibody 8A, which recognizes a human plasma cell-associated antigen, was covalently linked to xanthine oxidase in a conjugate maintaining both immunological and enzymatic properties. A significant degree of target cell lysis was obtained at an enzyme concentration that was ineffective on non-target cells and on myeloid staminal cells (CFU-GM). The cytotoxic activity was abolished by an excess of antibody, by allopurinol and by superoxide dismutase and catalase. A possible use of the conjugate for bone marrow purging in multiple myeloma patients is suggested.

  6. Validation of a KHV antibody enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Bergmann, S M; Wang, Q; Zeng, W; Li, Y; Wang, Y; Matras, M; Reichert, M; Fichtner, D; Lenk, M; Morin, T; Olesen, N J; Skall, H F; Lee, P-Y; Zheng, S; Monaghan, S; Reiche, S; Fuchs, W; Kotler, M; Way, K; Bräuer, G; Böttcher, K; Kappe, A; Kielpinska, J

    2017-11-01

    Koi herpesvirus (KHV) causes KHV disease (KHVD). The virus is highly contagious in carp or koi and can induce a high mortality. Latency and, in some cases, a lack of signs presents a challenge for virus detection. Appropriate immunological detection methods for anti-KHV antibodies have not yet been fully validated for KHV. Therefore, it was developed and validated an enzyme-linked immunosorbent assay (ELISA) to detect KHV antibodies. The assay was optimized with respect to plates, buffers, antigens and assay conditions. It demonstrated high diagnostic and analytical sensitivity and specificity and was particularly useful at the pond or farm levels. Considering the scale of the carp and koi industry worldwide, this assay represents an important practical tool for the indirect detection of KHV, also in the absence of clinical signs. © 2017 John Wiley & Sons Ltd.

  7. Determination of relative assay response factors for toxic chlorinated and brominated dioxins/furans using an enzyme immunoassay (EIA) and a chemically-activated luciferase gene expression cell bioassay (CALUX).

    Science.gov (United States)

    Samara, Fatin; Gullett, Brian K; Harrison, Robert O; Chu, Andrew; Clark, George C

    2009-04-01

    Determination of toxic activity requires knowledge of both the concentration and toxicity to evaluate the risk for adverse human health and environmental effects. A chemically-activated luciferase gene expression cell bioassay system (CALUX) and an antibody-based method enzyme immunoassay (EIA) were used to detect the dioxin-like response of several polybrominated, polychlorinated, and polybrominated/chlorinated dibenzo-p-dioxins/furans (PBDDs/Fs, PCDDs/Fs, and PBCDDs/Fs, respectively). It has been suggested that the biological activity of the brominated and mixed bromo/chloro compounds is similar to their chlorinated analogues (measured by binding to the Ah receptor). PBDD/F, PCDD/F, and PBCDD/F laboratory standards exhibited biological activity ranging over three orders of magnitude. The highest relative potency (REP) values from CALUX analysis, when compared to 2,3,7,8-TCDD, were 2,3,7,8-TBDD at 0.99 (+/-0.07), 1,2,3,7,8-PeCDD at 0.69, and 2-Br-3,7,8-TriCDD at 0.72 (+/-0.02). Cross-reactivities were calculated using EIA for several PBDDs/Fs and PBCDDs. The highest percent cross-reactivity was found for 2,3,7,8-TBDD at 138 (+/-34%), and 2,3,7-TriBDD at 84 (+/-36%).

  8. Monoclonal Antibodies Against Fusicoccin with Binding Characteristics Similar to the Putative Fusicoccin Receptor of Higher Plants 1

    Science.gov (United States)

    Feyerabend, Martin; Weiler, Elmar W.

    1987-01-01

    Monoclonal antibodies were raised against fusicoccin. The toxin, linked to bovine serum albumin through its t-pentenyl moiety, served as immunogen. Hybridomas secreting anti-fusicoccin antibodies were screened by radioimmunoassay employing a novel radioactive derivative, [3H]-nor-fusicoccin-alcohol of high specific activity (1.5 × 1014Bq/mole). The two monoclonal antibodies reported here are of high apparent affinity for fusicoccin (0.71 × 10−9 molar and 1.85 × 10−9 molar). This is comparable to the apparent affinity of rabbit antiserum raised against the same type of conjugate (9.3 × 10−9 molar). A method for the single step purification of the monoclonal antibodies from ascites fluid is reported. A solid-phase immunoassay, using alkaline phosphatase as enzyme, exhibits a measuring range from 0.1 to 1.5 picomoles (about 70 picograms to 1 nanogram) of fusicoccin. The displacement of [3H]-nor-fusicoccin-alcohol from the antibodies by compounds structurally related to fusicoccin exhibits similar selectivity as a microsomal binding assay with the same tracer as radiolabeled probe. Images Fig. 2 PMID:16665786

  9. Use of enzyme immunoassays in disease diagnosis, with particular reference to rinderpest

    International Nuclear Information System (INIS)

    Crowther, J.R.

    1986-01-01

    The wider principles of the use of enzyme linked immunosorbent assays (ELISA) in diagnosis are illustrated. The development of an antirinderpest antibody assay is explained in order to demonstrate the relative ease with which the test can be set up and used in various countries. The various stages of the test can be standardized in central laboratories; for example, antigen (inactivated) can be prepared and passively attached to microplates. Purchasing and titration of conjugates and selection of negative control sera could also be done centrally. Thus 'kits' for the initiation of diagnosis could be rapidly made available. When assays have been used in specific countries to study antibody populations in large numbers of animals, it may be found necessary to modify the above procedures; for example, different negative sera may be necessary, reflecting the mean (and distribution) of the country. Relatively simple standardization steps to titrate antigen, conjugates and sera would allow assays to be set up in individual countries with no need for outside standardization. However, it may be useful to obtain sero-negative and sero-positive standards from an outside source which could be used on a worldwide basis for interlaboratory standardization. The provision of washing solution, blocking buffers, plates, pipettes and readers is the only requisite for the versatility of ELISA to be fully realized in the study of many disease agents. (author)

  10. Detection of antibodies to hepatitis B core antigen using the Abbott ARCHITECT anti-HBc assay: analysis of borderline reactive sera.

    Science.gov (United States)

    Ollier, Laurence; Laffont, Catherine; Kechkekian, Aurore; Doglio, Alain; Giordanengo, Valérie

    2008-12-01

    Routine use of the automated chemiluminescent microparticle immunoassay Abbott ARCHITECT anti-HBc for diagnosis of hepatitis B is limited in case of borderline reactive sera with low signal close to the cut-off index. In order to determine the significance of anti-HBc detection when borderline reactivity occurs using the ARCHITECT anti-HBc assay, a comparative study was designed. 3540 serum samples collected over a 2-month period in the hospital of Nice were examined for markers of HBV infection (HBsAg, anti-HBs and anti-HBc). One hundred seven samples with sufficient volume and with borderline reactivity by the ARCHITECT assay were tested by two other anti-HBc assays, a microparticle enzyme immunoassay (MEIA, AxSYM Core, Abbott Laboratories, IL, USA) and an enzyme linked fluorescent assay (ELFA, VIDAS Anti-HBc Total II, bioMérieux, Lyon, France). Only 46 samples were confirmed by the AxSYM and the VIDAS assays. Additional serological information linked to patient history showed that the remaining samples (61) were false positives (11), had low titer of anti-HBc antibodies (13), or were inconclusive (37). This comparative study highlighted the existence of a grey zone around the cut-off index. Confirmative results through a different immunoassay are needed to confirm the diagnosis of HBV on borderline reactive sera using the ARCHITECT anti-HBc assay.

  11. Enzyme-Linked Immunosorbent Assay Specific for (1→6) Branched, (1→3)-β-d-Glucan Detection in Environmental Samples

    OpenAIRE

    Milton, Donald K.; Alwis, K. Udeni; Fisette, Leslie; Muilenberg, Michael

    2001-01-01

    (1→3)-β-d-Glucans have been recognized as a potential causative agent responsible for bioaerosol-induced respiratory symptoms observed in both indoor and occupational environments. A specific enzyme immunoassay was developed to quantify (1→6) branched, (1→3)-β-d-glucans in environmental samples. The assay was based on the use of a high-affinity receptor (galactosyl ceramide) specific for (1→3)-β-d-glucans as a capture reagent and a monoclonal antibody specific for fungal cell wall β-d-glucans...

  12. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Rui [College of Life Science, Nanchang University, Nanchang, 330031 (China); State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua [State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Xiong, Yonghua, E-mail: yhxiongchen@163.com [College of Life Science, Nanchang University, Nanchang, 330031 (China); State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China)

    2016-12-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H{sub 2}O{sub 2}) and H{sub 2}O{sub 2}-sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H{sub 2}O{sub 2} and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H{sub 2}O{sub 2}, as well as the incubation time between H{sub 2}O{sub 2} and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10{sup 2} CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10{sup 3} CFU/mL to 1.18 × 10{sup 6} CFU/mL were in the range of 65.88%–105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. - Highlights: • A novel fluorescence immunoassay was developed for the ultrasensitive detection of E. coli O157:H7. • This detection was achieved through the combination of the high bioactivity of CAT and H{sub 2}O{sub 2}-sensitive QDs. • The activity of CAT to H{sub 2}O{sub 2} is 1000 folds higher than that of the HRP

  13. Production of Mouse Monoclonal Antibody against Morphine without Cross Reactivity with Heroin

    Directory of Open Access Journals (Sweden)

    S Kashaninan

    2014-12-01

    Conclusion: The study findings revealed that the produced antibody against morphine was comparable with other antibodies for specificity and affinity; therefore it is usable in design of diagnostic immunoassay in biologic fluids.

  14. Identification of Performance Problems in a Commercial Human Immunodeficiency Virus Type 1 Enzyme Immunoassay by Multiuser External Quality Control Monitoring and Real-Time Data Analysis▿ †

    OpenAIRE

    Kim, J.; Swantee, C.; Lee, B.; Gunning, H.; Chow, A.; Sidaway, F.; Sherlock, C.; Garceau, R.; Dimech, W.; Malloch, L.

    2009-01-01

    In June 2005, a pilot program was implemented in Canadian laboratories to monitor the performance of the Abbott human immunodeficiency virus types 1 and 2 (HIV-1/2) gO enzyme immunoassay (EIA). Two different external quality control (QC) reagents and a “real-time” software analysis program were evaluated. In November 2005, higher-than-expected calibrator rate values in these kits were first reported at the Ontario Ministry of Health (Etobicoke), followed by the Alberta Provincial Public Healt...

  15. Quantitative measurement of ultraviolet-induced damage in cellular DNA by an enzyme immunodot assay

    International Nuclear Information System (INIS)

    Wakizaka, A.; Nishizawa, Y.; Aiba, N.; Okuhara, E.; Takahashi, S.

    1989-01-01

    A simple enzyme immunoassay procedure was developed for the quantitative determination of 254-nm uv-induced DNA damage in cells. With the use of specific antibodies to uv-irradiated DNA and horseradish peroxidase-conjugated antibody to rabbit IgG, the extent of damaged DNA in uv-irradiated rat spleen mononuclear cells was quantitatively measurable. Through the use of this method, the amount of damaged DNA present in 2 X 10(5) cells irradiated at a dose of 75 J/m2 was estimated to be 7 ng equivalents of the standard uv-irradiated DNA. In addition, when the cells, irradiated at 750 J/m2, were incubated for 1 h, the antigenic activity of DNA decreased by 40%, suggesting that a repair of the damaged sites in DNA had proceeded to some extent in the cells

  16. A sensitive monoclonal antibody-based enzyme-linked immunosorbent assay for chlorpyrifos residue determination in Chinese agricultural smaples

    Science.gov (United States)

    A monoclonal antibody-based competitive antibody-coated enzyme-linked immunosorbent assay (ELISA) was developed and optimized for determining chlorpyrifos residue in agricultural products. The IC50 and IC10 of this ELISA were 3.3 ng/mL and 0.1 ng/mL respectively. The average recoveries recovery rate...

  17. Clostridium difficile Testing Algorithm: Is There a Difference in Patients Who Test Positive by Enzyme Immunoassay vs. Those Who Only Test Positive by Nucleic Acid Amplification Methodology?

    OpenAIRE

    Polak, Jonathan; Odili, Ogheneruona; Craver, Mary Ashleigh; Mayen, Anthony; Purrman, Kyle; Rahman, Asem; Sang, Charlie Joseph; Cook, Paul P

    2017-01-01

    Abstract Background Testing for Clostridium difficile infection (CDI) commonly involves checking for the presence of toxins A and B by enzyme immunoassay (EIA) or nucleic acid amplification (NAA). The former is very specific, but not very sensitive. The latter is very sensitive. Beginning in 2011, our hospital incorporated an algorithm that involved testing liquid stool specimens for glutamate dehydrogenase (GDH) and toxin by EIA. For discrepant results, the stool specimen was tested for the ...

  18. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    Science.gov (United States)

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  19. An Ultrasensitive Electrochemiluminescence Immunoassay for Carbohydrate Antigen 19-9 in Serum Based on Antibody Labeled Fe3O4 Nanoparticles as Capture Probes and Graphene/CdTe Quantum Dot Bionanoconjugates as Signal Amplifiers

    Science.gov (United States)

    Gan, Ning; Zhou, Jing; Xiong, Ping; Li, Tianhua; Jiang, Shan; Cao, Yuting; Jiang, Qianli

    2013-01-01

    The CdTe quantum dots (QDs), graphene nanocomposite (CdTe-G) and dextran–Fe3O4 magnetic nanoparticles have been synthesized for developing an ultrasensitive electrochemiluminescence (ECL) immunoassay for Carcinoembryonic antigen 19-9 (CA 19-9) in serums. Firstly, the capture probes (CA 19-9 Ab1/Fe3O4) for enriching CA 19-9 were synthesized by immobilizing the CA 19-9’s first antibody (CA 19-9 Ab1) on magnetic nanoparticles (dextran-Fe3O4). Secondly, the signal probes (CA 19-9 Ab2/CdTe-G), which can emit an ECL signal, were formed by attaching the secondary CA 19-9 antibody (CA 19-9 Ab2) to the surface of the CdTe-G. Thirdly, the above two probes were used for conjugating with a serial of CA 19-9 concentrations. Graphene can immobilize dozens of CdTe QDs on their surface, which can emit stronger ECL intensity than CdTe QDs. Based on the amplified signal, ultrasensitive antigen detection can be realized. Under the optimal conditions, the ECL signal depended linearly on the logarithm of CA 19-9 concentration from 0.005 to 100 pg/mL, and the detection limit was 0.002 pg/mL. Finally, five samples of human serum were tested, and the results were compared with a time-resolved fluorescence assay (TRFA). The novel immunoassay provides a stable, specific and highly sensitive immunoassay protocol for tumor marker detection at very low levels, which can be applied in early diagnosis of tumor. PMID:23685872

  20. Development of a monoclonal antibody to urinary degradation products from the C-terminal telopeptide alpha 1 chain of type I collagen. Application in an enzyme Immunoassay and comparison to CrossLaps(TM) ELISA

    DEFF Research Database (Denmark)

    C, Fledelius; I, Kolding; P, Quist

    1997-01-01

    A monoclonal antibody MAbA7 was raised against a synthetic peptide having a sequence (EKAHDGGR) specific for a part of the C-telopeptide alpha 1 chain of type I collagen. MAbA7 was labelled with horseradish peroxide and used in a competitive one-step enzyme-linked immunosorbent assay (ELISA...... concentrations decreased 88% (pantibody and the new assay may be useful for further investigations of the physiological...

  1. Simultaneous detection of IgG antibodies associated with viral hemorrhagic fever by a multiplexed Luminex-based immunoassay.

    Science.gov (United States)

    Wu, Wei; Zhang, Shuo; Qu, Jing; Zhang, Quanfu; Li, Chuan; Li, Jiandong; Jin, Cong; Liang, Mifang; Li, Dexin

    2014-07-17

    Viral hemorrhagic fevers (VHFs) are worldwide diseases caused by several kinds of viruses. With the emergence of new viruses, advanced diagnostic methods are urgently needed for identification of VHFs. Based on Luminex xMAP technology, a rapid, sensitive, multi-pathogen and high-throughput method which could simultaneously detect hemorrhagic fever viruses (HFVs) specific IgG antibodies was developed. Recombinant antigens of nine HFVs including Hantaan virus (HTNV), Seoul virus (SEOV), Puumala virus (PUUV), Andes virus (ANDV), Sin Nombre virus (SNV), Crimean-Congo hemorrhagic fever virus (CCHFV), Rift Valley fever virus (RVFV), Severe fever with thrombocytopenia syndrome bunyavirus (SFTSV) and dengue virus (DENV) were produced and purified from a prokaryotic expression system and the influence of the coupling amount was investigated. Cross-reactions among antigens and their rabbit immune sera were evaluated. Serum samples collected from 51 laboratory confirmed hemorrhagic fever with renal syndrome (HFRS) patients, 43 confirmed SFTS patients and 88 healthy donors were analyzed. Results showed that recombinant nucleocapsid protein of the five viruses belonging to the genus Hantavirus, had serological cross-reactivity with their corresponding rabbit immune sera, but not apparent with immune sera of other four viruses. Evaluation of this new method with clinical serum samples showed 98.04% diagnostic sensitivity for HFRS, 90.70% for SFTS detection and the specificity was ranging from 66.67% to 100.00%. The multiplexed Luminex-based immunoassay has firstly been established in our study, which provides a potentially reliable diagnostic tool for IgG antibody detection of VHFs. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads

    International Nuclear Information System (INIS)

    Zhang Ruiq; Nakajima, Hizuru; Soh, Nobuaki; Nakano, Koji; Masadome, Takashi; Nagata, Kazumi; Sakamoto, Kazuhira; Imato, Toshihiko

    2007-01-01

    A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm

  3. False biochemical diagnosis of hyperthyroidism in streptavidin-biotin-based immunoassays: the problem of biotin intake and related interferences.

    Science.gov (United States)

    Piketty, Marie-Liesse; Polak, Michel; Flechtner, Isabelle; Gonzales-Briceño, Laura; Souberbielle, Jean-Claude

    2017-05-01

    Immunoassays are now commonly used for hormone measurement, in high throughput analytical platforms. Immunoassays are generally robust to interference. However, endogenous analytical error may occur in some patients; this may be encountered in biotin supplementation or in the presence of anti-streptavidin antibody, in immunoassays involving streptavidin-biotin interaction. In these cases, the interference may induce both false positive and false negative results, and simulate a seemingly coherent hormonal profile. It is to be feared that this type of errors will be more frequently observed. This review underlines the importance of keeping close interactions between biologists and clinicians to be able to correlate the hormonal assay results with the clinical picture.

  4. [The efficiency of the enzyme immunoassay test system opisthorchiasis-CIC-EIA-best to detect circulating immune complexes containing opisthorchis antigens in the serum of patients with opisthorchiasis].

    Science.gov (United States)

    Starkova, T V; Poletaeva, O G; Kovrova, E A; Krasovskaia, N N; Tkachenko, T N; Masiago, A V; Ofitserov, V I; Tereshchenko, A Iu

    2011-01-01

    The efficacy of a kit of Opisthorchiasis-CIC-EIA-Best reagents was evaluated using 270 sera from patients in the study and control groups. The kit showed a sufficient sensitivity (not less than 87.2%) and a high specificity (not less than 97.9%). The use of the above kit of the reagents for enzyme immunoassay in practical healthcare enables one to increase detection rates among the infested subjects on comprehensive examination of those with suspected opisthorchiasis.

  5. Antibody-mediated enzyme replacement therapy targeting both lysosomal and cytoplasmic glycogen in Pompe disease.

    Science.gov (United States)

    Yi, Haiqing; Sun, Tao; Armstrong, Dustin; Borneman, Scott; Yang, Chunyu; Austin, Stephanie; Kishnani, Priya S; Sun, Baodong

    2017-05-01

    Pompe disease is characterized by accumulation of both lysosomal and cytoplasmic glycogen primarily in skeletal and cardiac muscles. Mannose-6-phosphate receptor-mediated enzyme replacement therapy (ERT) with recombinant human acid α-glucosidase (rhGAA) targets the enzyme to lysosomes and thus is unable to digest cytoplasmic glycogen. Studies have shown that anti-DNA antibody 3E10 penetrates living cells and delivers "cargo" proteins to the cytosol or nucleus via equilibrative nucleoside transporter ENT2. We speculate that 3E10-mediated ERT with GAA will target both lysosomal and cytoplasmic glycogen in Pompe disease. A fusion protein (FabGAA) containing a humanized Fab fragment derived from the murine 3E10 antibody and the 110 kDa human GAA precursor was constructed and produced in CHO cells. Immunostaining with an anti-Fab antibody revealed that the Fab signals did not co-localize with the lysosomal marker LAMP2 in cultured L6 myoblasts or Pompe patient fibroblasts after incubation with FabGAA. Western blot with an anti-GAA antibody showed presence of the 150 kDa full-length FabGAA in the cell lysates, in addition to the 95- and 76 kDa processed forms of GAA that were also seen in the rhGAA-treated cells. Blocking of mannose-6-phosphate receptor with mannose-6-phosphate markedly reduced the 95- and the 76 kDa forms but not the 150 kDa form. In GAA-KO mice, FabGAA achieved similar treatment efficacy as rhGAA at an equal molar dose in reducing tissue glycogen contents. Our data suggest that FabGAA retains the ability of rhGAA to treat lysosomal glycogen accumulation and has the beneficial potential over rhGAA to reduce cytoplasmic glycogen storage in Pompe disease. FabGAA can be delivered to both the cytoplasm and lysosomes in cultured cells. FabGAA equally reduced lysosomal glycogen accumulation as rhGAA in GAA-KO mice. FabGAA has the beneficial potential over rhGAA to clear cytoplasmic glycogen. This study suggests a novel antibody-enzyme fusion protein therapy

  6. Antibodies and Selection of Monoclonal Antibodies.

    Science.gov (United States)

    Hanack, Katja; Messerschmidt, Katrin; Listek, Martin

    Monoclonal antibodies are universal binding molecules with a high specificity for their target and are indispensable tools in research, diagnostics and therapy. The biotechnological generation of monoclonal antibodies was enabled by the hybridoma technology published in 1975 by Köhler and Milstein. Today monoclonal antibodies are used in a variety of applications as flow cytometry, magnetic cell sorting, immunoassays or therapeutic approaches. First step of the generation process is the immunization of the organism with appropriate antigen. After a positive immune response the spleen cells are isolated and fused with myeloma cells in order to generate stable, long-living antibody-producing cell lines - hybridoma cells. In the subsequent identification step the culture supernatants of all hybridoma cells are screened weekly for the production of the antibody of interest. Hybridoma cells producing the antibody of interest are cloned by limited dilution till a monoclonal hybridoma is found. This is a very time-consuming and laborious process and therefore different selection strategies were developed since 1975 in order to facilitate the generation of monoclonal antibodies. Apart from common automation of pipetting processes and ELISA testing there are some promising approaches to select the right monoclonal antibody very early in the process to reduce time and effort of the generation. In this chapter different selection strategies for antibody-producing hybridoma cells are presented and analysed regarding to their benefits compared to conventional limited dilution technology.

  7. Immunoassay: Principles, development and potential applications in the applied plant sciences

    Energy Technology Data Exchange (ETDEWEB)

    Hofman, P J

    1986-02-01

    The article briefly discusses the general principles of, and the methods involved in, immunoassay, and their development. Emplasis is placed on radioimmunoassay (RIA) and to a lesser extent, enzyme-linked immunosorbent assay (ELISA). The practical applications, with special reference to the citrus and subtropical fruit industries are discussed.

  8. Development of recombinant antibody technology for application in plant pathogen diagnosis

    NARCIS (Netherlands)

    Griep, R.

    1999-01-01

    This thesis describes the applicability of the novel phage display technique to select plant-pathogen-specific monoclonal antibodies (MAbs) from combinatorial antibody libraries. The retrieved MAbs are so specific that they can be used as diagnostic tools in sensitive immunoassays for the

  9. Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays.

    Science.gov (United States)

    Chan, Conrad E Z; Chan, Annie H Y; Lim, Angeline P C; Hanson, Brendon J

    2011-10-28

    Rapid development of diagnostic immunoassays against novel emerging or genetically modified pathogens in an emergency situation is dependent on the timely isolation of specific antibodies. Non-immune antibody phage display libraries are an efficient in vitro method for selecting monoclonal antibodies and hence ideal in these circumstances. Such libraries can be constructed from a variety of sources e.g. B cell cDNA or synthetically generated, and use a variety of antibody formats, typically scFv or Fab. However, antibody source and format can impact on the quality of antibodies generated and hence the effectiveness of this methodology for the timely production of antibodies. We have carried out a comparative screening of two antibody libraries, a semi-synthetic scFv library and a human-derived Fab library against the protective antigen toxin component of Bacillus anthracis and the epsilon toxin of Clostridium botulinum. We have shown that while the synthetic library produced a diverse collection of specific scFv-phage, these contained a high frequency of unnatural amber stops and glycosylation sites which limited their conversion to IgG, and also a high number which lost specificity when expressed as IgG. In contrast, these limitations were overcome by the use of a natural human library. Antibodies from both libraries could be used to develop sandwich ELISA assays with similar sensitivity. However, the ease and speed with which full-length IgG could be generated from the human-derived Fab library makes screening this type of library the preferable method for rapid antibody generation for diagnostic assay development. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Isolation and expression of recombinant antibody fragments to the biological warfare pathogen Brucella melitensis.

    Science.gov (United States)

    Hayhurst, Andrew; Happe, Scott; Mabry, Robert; Koch, Zephyr; Iverson, Brent L; Georgiou, George

    2003-05-01

    Brucella melitensis is a highly infectious animal pathogen able to cause a recurring debilitating disease in humans and is therefore high on the list of biological warfare agents. Immunoglobulin genes from mice immunized with gamma-irradiated B. melitensis strain 16M were used to construct a library that was screened by phage display against similarly prepared bacteria. The selected phage particles afforded a strong enzyme-linked immunosorbent assay (ELISA) signal against gamma-irradiated B. melitensis cells. However, extensive efforts to express the respective single chain antibody variable region fragment (scFv) in soluble form failed due to: (i) poor solubility and (ii) in vivo degradation of the c-myc tag used for the detection of the recombinant antibodies. Both problems could be addressed by: (i) fusing a human kappa light chain constant domain (Ck) chain to the scFv to generate single chain antibody fragment (scAb) antibody fragments and (ii) by co-expression of the periplasmic chaperone Skp. While soluble, functional antibodies could be produced in this manner, phage-displaying scFvs or scAbs were still found to be superior ELISA reagents for immunoassays, due to the large signal amplification afforded by anti-phage antibodies. The isolated phage antibodies were shown to be highly specific to B. melitensis and did not recognize Yersinia pseudotuberculosis in contrast to the existing diagnostic monoclonal YST 9.2.1.

  11. A radioligand immunoassay for 1,25-dihydroxyvitamin D3 receptors using monoclonal antibody: detection of a phenotypic receptor variant in vitamin D-dependency rickets (type II) which does not bind hormone

    International Nuclear Information System (INIS)

    Pike, J.W.; Dokoh, Shigeharu; Liberman, U.A.; Eil, C.; Haussler, M.R.; Marx, S.J.

    1984-01-01

    Vitamin D-dependency rickets, type II (VDDRII), is a well recognized heritable disorder characterized by peripheral target organ resistance to 1,25-dihydroxyvitamin D 3 (1,25(OH) 2 D 3 ), the hormonally active form of the vitamin. Recently, cultured skin fibroblasts obtained from a number of patients with VDDRII have been utilized to characterize the underlying molecular defects associated with this malady. Recently monoclonal antibodies to the vitamin D receptor have been generated, and a radioligand immunoassay (RLIA) for the detection of this molecule has been developed which is independent of its hormone-binding capacity. This report describes the application of the immunoassay in the detection of receptor-like molecules in fibroblasts derived from patients with VDDRII. The results indicate that the molecule is generally present in all patients, and provides a mechanism for individual responsiveness to pharmacologic treatment with vitamin D 3 metabolites. 8 refs.; 3 figs.; 1 table

  12. Supersensitive gastrin assay using antibodies raised against a cholecystokinin homolog

    DEFF Research Database (Denmark)

    Rehfeld, Jens F; Ericsson, Peter

    2012-01-01

    Peptide hormones may occur in particularly low amounts in samples from small animals. Hence, in a rat microdialysis study conventional immunoassays were not sufficiently sensitive to measure gastrin in the dialysis samples. We therefore exploited the observation that antibodies raised against...... that obtained with the most avid conventional gastrin antibodies. The results may encourage similar approaches for other peptides using homologue-raised antibodies when supersensitivity is required....

  13. Engineered antibodies for monitoring of polynuclear aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Karu, A.E.; Li, Q.X.; Roberts, V.A.

    1998-01-01

    'The long-term goal of this project is to develop antibodies and antibody-based methods for detection and recovery of polynuclear aromatic hydrocarbons (PAHs) and PAH adducts that are potential biomarkers in environmental and biological samples. The inherent cross-reactivity will be exploited by pattern recognition methods. Dr. Karu''s laboratory uses new haptens representing key PAHs to derive recombinant Fab (rFab) and single-chain Fv (scFv) antibodies from hybridoma lines and combinatorial phage display libraries. Computational models of the haptens and combining sites made by Dr. Roberts''s group are used to guide antibody engineering by mutagenesis. Dr. Li''s laboratory develops enzyme immunoassays (EIAs), sensors, and immunoaffinity methods that make use of the novel haptens and antibodies for practical analytical applications in support of DOE''s mission. This report summarizes work completed in one and one-half years of a 3-year project, with close collaboration between the three research groups. Dr. Alexander Karu''s laboratory: the authors proceeded with the two strategies described in the original proposal. Site-directed mutagenesis was used to correct differences in the rFab N-terminal amino acids that were introduced by the degenerate PCR primers used for gene amplification. The binding constants of the rFabs with the corrected sequences will be compared with those of the parent MAbs, and should be very similar. The 4D5 and 10C10 heavy and light chain sequences are being moved to the pCOMB3H phagemid vector to facilitate selection of new engineered mutants.'

  14. Discordant Analytical Results Caused by Biotin Interference on Diagnostic Immunoassays in a Pediatric Hospital.

    Science.gov (United States)

    Ali, Mahesheema; Rajapakshe, Deepthi; Cao, Liyun; Devaraj, Sridevi

    2017-09-01

    Recent studies have reported that biotin interferes with certain immunoassays. In this study, we evaluated the analytical interference of biotin on immunoassays that use streptavidin-biotin in our pediatric hospital. We tested the effect of different concentrations of biotin (1.5-200 ng/ml) on TSH, Prolactin, Ferritin, CK-MB, β-hCG, Troponin I, LH, FSH, Cortisol, Anti-HAV antibody (IgG and IgM), assays on Ortho Clinical Diagnostic Vitros 5600 Analyzer. Biotin (up to 200 ng/mL) did not significantly affect Troponin I and HAV assays. Biotin (up to 12.5 ng/ml) resulted in biotin >6.25 ng/mL significantly affected TSH (>20% bias) assay. Prolactin was significantly affected even at low levels (Biotin 1.5 ng/mL). Thus, we recommend educating physicians about biotin interference in common immunoassays and adding an electronic disclaimer. © 2017 by the Association of Clinical Scientists, Inc.

  15. Multiplex immunoassays for quantification of cytokines, growth factors, and other proteins in stem cell communication

    Czech Academy of Sciences Publication Activity Database

    Valeková, Ivona; Kupcová Skalníková, Helena; Jarkovská, Karla; Motlík, Jan; Kovářová, Hana

    -, č. 1212 (2015), s. 39-63 ISSN 1940 -6029 R&D Projects: GA MŠk ED2.1.00/03.0124; GA TA ČR(CZ) TA01011466 Institutional support: RVO:67985904 Keywords : multiplex immunoassays * antibody microarray * luminex xMAP Subject RIV: EB - Genetics ; Molecular Biology

  16. Comparison of enzyme immunoassays for antibodies to Haemophilus ducreyi in a community outbreak of chancroid in the United States.

    Science.gov (United States)

    Chen, C Y; Mertz, K J; Spinola, S M; Morse, S A

    1997-06-01

    The performance of two EIAs (adsorption EIA and lipooligosaccharide [LOS] EIA) that detect antibodies to Haemophilus ducreyi was evaluated with serum specimens obtained from 163 patients (96 with genital ulcer disease [GUD]). Paired serum specimens (initial and follow-up) were obtained from 52 of the GUD patients. By use of initial serum specimens from 82 GUD patients whose etiologic agents for their ulcers had been identified, the adsorption EIA had a sensitivity and specificity for chancroid of 53% and 71%, while the LOS EIA had a sensitivity and specificity of 48% and 89%, respectively. Sensitivity and specificity of the adsorption EIA increased to 78% and 84%, respectively, when the results of follow-up serum specimens were used to calculate optimal performance. The proportion of patients testing positive for H. ducreyi who had anti-H. ducreyi IgG antibodies, as determined by adsorption EIA, increased with the duration of infection, thus limiting the role of EIAs in the diagnosis of chancroid.

  17. Development of flow-through and dip-stick immunoassays for screening of sulfonamide residues.

    Science.gov (United States)

    Zhang, Hongyan; Zhang, Yan; Wang, Shuo

    2008-08-20

    Two formats of membrane-based competitive enzyme immunoassays (flow-through and dip-stick) have been developed for the screening of sulfonamide residues in pig muscle and milk. Membrane was coated with anti-sulfonamide antibody and a sulfonamide hapten D2-horseradish peroxidase (HRP) conjugant was used as the labeled antigen for competitive assay of sulfonamides. Visual detection limits of the flow-through or dip-stick assay were 1-5 microg L(-1) or 1-10 microg L(-1) in buffer for seven sulfonamides, respectively. Assay validation was performed using samples spiked with single sulfonamide, spiked samples were tested using the developed strip assays and results were compared with those obtained by a validated high-performance liquid chromatograph (HPLC) method. Results showed that the two strip assays were correlated well with HPLC, respectively. With assay times of 5 min (flow-through) and 15 min (dip-stick), these rapid tests could offer simple, rapid and cost-effective on-site screening tools to detect sulfonamides in pig muscle (flow-through or dip-stick) or milk (only dip-stick).

  18. A comparison of the performance of molecularly imprinted polymer nanoparticles for small molecule targets and antibodies in the ELISA format

    Science.gov (United States)

    Smolinska-Kempisty, Katarzyna; Guerreiro, Antonio; Canfarotta, Francesco; Cáceres, César; Whitcombe, Michael J.; Piletsky, Sergey

    2016-11-01

    Here we show that molecularly imprinted polymer nanoparticles, prepared in aqueous media by solid phase synthesis with immobilised L-thyroxine, glucosamine, fumonisin B2 or biotin as template, can demonstrate comparable or better performance to commercially produced antibodies in enzyme-linked competitive assays. Imprinted nanoparticles-based assays showed detection limits in the pM range and polymer-coated microplates are stable to storage at room temperature for at least 1 month. No response to analyte was detected in control experiments with nanoparticles imprinted with an unrelated template (trypsin) but prepared with the same polymer composition. The ease of preparation, high affinity of solid-phase synthesised imprinted nanoparticles and the lack of requirement for cold chain logistics make them an attractive alternative to traditional antibodies for use in immunoassays.

  19. A sensitive chemiluminescence enzyme immunoassay based on molecularly imprinted polymers solid-phase extraction of parathion.

    Science.gov (United States)

    Chen, Ge; Jin, Maojun; Du, Pengfei; Zhang, Chan; Cui, Xueyan; Zhang, Yudan; She, Yongxin; Shao, Hua; Jin, Fen; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2017-08-01

    The chemiluminescence enzyme immunoassay (CLEIA) method responds differently to various sample matrices because of the matrix effect. In this work, the CLEIA method was coupled with molecularly imprinted polymers (MIPs) synthesized by precipitation polymerization to study the matrix effect. The sample recoveries ranged from 72.62% to 121.89%, with a relative standard deviation (RSD) of 3.74-18.14%.The ratio of the sample matrix-matched standard curve slope rate to the solvent standard curve slope was 1.21, 1.12, 1.17, and 0.85 for apple, rice, orange and cabbage in samples pretreated with the mixture of PSA and C 18 . However, the ratio of sample (apple, rice, orange, and cabbage) matrix-matched standard-MIPs curve slope rate to the solvent standard curve was 1.05, 0.92, 1.09, and 1.05 in samples pretreated with MIPs, respectively. The results demonstrated that the matrices of the samples greatly interfered with the detection of parathion residues by CLEIA. The MIPs bound specifically to the parathion in the samples and eliminated the matrix interference effect. Therefore, the CLEIA method have successfully applied MIPs in sample pretreatment to eliminate matrix interference effects and provided a new sensitive assay for agro-products. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: An anticipated analytical tool for food safety

    International Nuclear Information System (INIS)

    Hervas, Miriam; Lopez, Miguel Angel; Escarpa, Alberto

    2009-01-01

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 μg L -1 and EC 50 0.079 μg L -1 were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  1. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: an anticipated analytical tool for food safety.

    Science.gov (United States)

    Hervás, Miriam; López, Miguel Angel; Escarpa, Alberto

    2009-10-27

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 microg L(-1) and EC(50) 0.079 microg L(-1) were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  2. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: An anticipated analytical tool for food safety

    Energy Technology Data Exchange (ETDEWEB)

    Hervas, Miriam; Lopez, Miguel Angel [Departamento Quimica Analitica, Universidad de Alcala, Ctra. Madrid-Barcelona, Km. 33600, E-28871 Alcala de Henares, Madrid (Spain); Escarpa, Alberto, E-mail: alberto.escarpa@uah.es [Departamento Quimica Analitica, Universidad de Alcala, Ctra. Madrid-Barcelona, Km. 33600, E-28871 Alcala de Henares, Madrid (Spain)

    2009-10-27

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 {mu}g L{sup -1} and EC{sub 50} 0.079 {mu}g L{sup -1} were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  3. Identification of a vesicular-arbuscular mycorrhizal fungus by using monoclonal antibodies in an enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Wright, S F; Morton, J B; Sworobuk, J E

    1987-09-01

    Spore morphology is currently used to identify species of vesicular-arbuscular mycorrhizal fungi. We report the first use of a highly specific immunological method for identification of a vesicular-arbuscular mycorrhizal fungus. Two monoclonal antibodies were produced against Glomus occultum. Monoclonal antibodies reacted strongly with both spores and hyphae in an indirect enzyme-linked immunosorbent assay. All other mycorrhizal (29 species) and nonmycorrhizal (5 species) fungi tested were nonreactive with the monoclonal antibodies. A single spore of G. occultum was detectable in the presence of high numbers of spores of other vesicular-arbuscular mycorrhizal fungi. Variation in the reaction of G. occultum isolates from West Virginia, Florida, and Colombia suggests that monoclonal antibodies may differentiate strains.

  4. Challenges for bovine viral diarrhoea virus antibody detection in bulk milk by antibody enzyme-linked immunosorbent assays due to changes in milk production levels

    DEFF Research Database (Denmark)

    Foddai, Alessandro; Enøe, Claes; Stockmarr, Anders

    2015-01-01

    Background: Bovine viral diarrhoea (BVD) is considered eradicated from Denmark. Currently, very few (if any) Danish cattle herds could be infected with BVD virus (BVDV). The Danish antibody blocking enzyme-linked immunosorbent assay (ELISA) has been successfully used during the Danish BVD eradica...

  5. Seroprevalence of IgG Antibodies against Mumps in Bulgarian Children under 18 Years of Age

    Directory of Open Access Journals (Sweden)

    Milena Karcheva

    2013-03-01

    Full Text Available Objective: The objective of this study was to determine the prevalence of IgG antibodies against mumps in a representative stratified sample of children under 18 years of age in Pleven district, Bulgaria. Study Design: Cross sectional study. Materials and Methods: A cross-sectional, sero-epidemiologic survey of 132 children aged under 18 years was conducted in Pleven district. They were distributed into two age groups: from 0 to 11 years old (n=80 and from 12 to 18 years old (n=52. An enzyme immunoassay (EIA was performed for indirect evidence of specific IgG antibodies in the serum. Results: The results showed that 41% of the investigated children were negative in terms of mumps IgG antibodies, 11% had borderline values and the remaining, approximately 48%, were positive. In the group of children aged 0 to 11 years who had received one dose of the mumps vaccine, 50% were negative for mumps IgG antibodies. In the second group of children aged 12 to 18 years who had received two vaccine doses, the percentage of participants negative for mumps IgG antibodies decreased significantly. Conclusion: Our observations emphasise the need to conduct expanded sero-epidemiological investigations of the populations most affected by mumps and to immunise susceptible individuals.

  6. IFSA: a microfluidic chip-platform for frit-based immunoassay protocols

    Science.gov (United States)

    Hlawatsch, Nadine; Bangert, Michael; Miethe, Peter; Becker, Holger; Gärtner, Claudia

    2013-03-01

    Point-of-care diagnostics (POC) is one of the key application fields for lab-on-a-chip devices. While in recent years much of the work has concentrated on integrating complex molecular diagnostic assays onto a microfluidic device, there is a need to also put comparatively simple immunoassay-type protocols on a microfluidic platform. In this paper, we present the development of a microfluidic cartridge using an immunofiltration approach. In this method, the sandwich immunoassay takes place in a porous frit on which the antibodies have immobilized. The device is designed to be able to handle three samples in parallel and up to four analytical targets per sample. In order to meet the critical cost targets for the diagnostic market, the microfluidic chip has been designed and manufactured using high-volume manufacturing technologies in mind. Validation experiments show comparable sensitivities in comparison with conventional immunofiltration kits.

  7. Staphylococcal enterotoxin-specific IgE antibodies in atopic dermatitis.

    Science.gov (United States)

    Ide, Fumihito; Matsubara, Tomoyo; Kaneko, Miho; Ichiyama, Takashi; Mukouyama, Tokuko; Furukawa, Susumu

    2004-06-01

    The authors clarified the clinical significance of the measurement of serum concentrations of specific IgE antibodies to staphylococcal enterotoxin (SE) A- and SEB in atopic dermatitis (AD). The serum concentrations of SEA- and SEB-specific IgE antibodies in 140 pediatric patients with AD were measured with an immuno CAP -radioallergosorbent test system (RAST). To check the cross-reaction of specific IgE antibodies to SEA/SEB and other allergens, the CAP RAST fluorescent enzyme immunoassay inhibition test was performed. Forty-seven patients (33.6%) tested positive for either SEA- or SEB-specific IgE antibodies. School children showed higher positive rates of SEA/SEB-specific IgE antibodies than infants or young children. The patients with severe AD and those with exacerbation of symptoms in summer, had higher positive rates of SEA/SEB-specific IgE antibodies than patients with mild AD or those with exacerbation in winter. In addition, the positive rates of specific IgE antibodies to both dog-dander and cat-dander were higher in patients with positive SEA/SEB-specific IgE antibodies than in patients with negative ones. No cross-reactions occurred among specific IgE antibodies to SEA/SEB and dog/cat dander with one patient's serum, which had positive IgE-specific antibodies against cat/dog dander and SEA/SEB. The positive rate of SEA/SEB-specific IgE antibodies in the patients with dogs and/or cats as pets was 48.4%, which was higher than in those with no pets. Atopic dermatitis patients who exhibit high positive rates of SEA/SEB-specific IgE antibodies were found to be school children, severe cases, cases with high serum concentrations of total IgE, cases with exacerbation in summer, and cases with dogs and/or cats as pets. The measurement of serum concentrations of specific IgE antibodies to SEA and SEB, thus has some value for evaluating AD patients.

  8. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    Science.gov (United States)

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  9. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    Energy Technology Data Exchange (ETDEWEB)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-11-19

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of ..beta..-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment.

  10. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    International Nuclear Information System (INIS)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-01-01

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of #betta#-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment

  11. Development of two highly sensitive immunoassays for detection of copper ions and a suite of relevant immunochemicals

    International Nuclear Information System (INIS)

    Zhao Hongwei; Nan Tiegui; Tan Guiyu; Gao Wei; Cao Zhen; Sun Shuo; Li Zhaohu; Li, Qing X.; Wang Baomin

    2011-01-01

    Highlights: · Two highly sensitive immunoassays for determination of Cu(II) at sub ppb levels. · The heterologous competitive enzyme linked immunosorbent assay for heavy metals. · Haptenated protein directly conjugated with HRP can reduce the loss of HRP activity. - Abstract: Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)-ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)-EDTA-BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)-EDTA-BSA-horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator-protein complexes such as EDTA-BSA and EDTA-BSA-HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules.

  12. Development of two highly sensitive immunoassays for detection of copper ions and a suite of relevant immunochemicals

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Hongwei [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China); Department of Molecular Biosciences and Bioengineering, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); Nan Tiegui; Tan Guiyu; Gao Wei; Cao Zhen; Sun Shuo; Li Zhaohu [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China); Li, Qing X., E-mail: qingl@hawaii.edu [Department of Molecular Biosciences and Bioengineering, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); Wang Baomin, E-mail: wbaomin@263.com [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China)

    2011-09-19

    Highlights: {center_dot} Two highly sensitive immunoassays for determination of Cu(II) at sub ppb levels. {center_dot} The heterologous competitive enzyme linked immunosorbent assay for heavy metals. {center_dot} Haptenated protein directly conjugated with HRP can reduce the loss of HRP activity. - Abstract: Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)-ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)-EDTA-BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)-EDTA-BSA-horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator-protein complexes such as EDTA-BSA and EDTA-BSA-HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules.

  13. Rapid and Highly Sensitive Non-Competitive Immunoassay for Specific Detection of Nodularin

    Directory of Open Access Journals (Sweden)

    Sultana Akter

    2017-09-01

    Full Text Available Nodularin (NOD is a cyclic penta-peptide hepatotoxin mainly produced by Nodularia spumigena, reported from the brackish water bodies of various parts of the world. It can accumulate in the food chain and, for safety reasons, levels of NOD not only in water bodies but also in food matrices are of interest. Here, we report on a non-competitive immunoassay for the specific detection of NOD. A phage display technique was utilized to interrogate a synthetic antibody phage library for binders recognizing NOD bound to an anti-ADDA (3-Amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4(E,6(E-dienoic acid monoclonal antibody (Mab. One of the obtained immunocomplex binders, designated SA32C11, showed very high specificity towards nodularin-R (NOD-R over to the tested 10 different microcystins (microcystin-LR, -dmLR, -RR, -dmRR, -YR, -LY, -LF, -LW, -LA, -WR. It was expressed in Escherichia coli as a single chain antibody fragment (scFv fusion protein and used to establish a time-resolved fluorometry-based assay in combination with the anti-ADDA Mab. The detection limit (blank + 3SD of the immunoassay, with a total assay time of 1 h 10 min, is 0.03 µg/L of NOD-R. This represents the most sensitive immunoassay method for the specific detection of NOD reported so far. The assay was tested for its performance to detect NOD using spiked (0.1 to 3 µg/L of NOD-R water samples including brackish sea and coastal water and the recovery ranged from 79 to 127%. Furthermore, a panel of environmental samples, including water from different sources, fish and other marine tissue specimens, were analyzed for NOD using the assay. The assay has potential as a rapid screening tool for the analysis of a large number of water samples for the presence of NOD. It can also find applications in the analysis of the bioaccumulation of NOD in marine organisms and in the food chain.

  14. Unexplained infertility: identification of anti sperm antibodies using radiometric immunoassay

    International Nuclear Information System (INIS)

    Megahed, Y.M.; Elnabarawy, F.; Hamada, T.; Ayiad, S.K.

    1992-01-01

    Several methods have been employed to measure anti sperm antibodies with variable sensitivity and specificity in serum and secretion of infertile patients. All of them are not precise means for identification of the presence of anti sperm antibodies for patients with unexplained infertility (Haas et al, 1980). Therefore, the modified radiolabelled anti globulin test, that has been used successfully to identify and quantitate the antibodies directed towards other human cell surfaces, was applied. A total number of 128 subjects in different groups were studied to quantitate the circulating anti sperm antibodies using the modified procedure. The present data revealed that the highest and the most significant incidence were found in the patients secretions (semen and cervical mucus) with unexplained infertility, as well as in the group of males with varicocele. Therefore it is greatly advisable to use the modified radiolabelled technique as a quantitative assay, which will be helpful in management of infertility in patients with unexplained and mediated infertility.3 tab., 4 fig

  15. Monoclonal antibody-based broad-specificity immunoassay for monitoring organophosphorus pesticides in environmental water samples

    Science.gov (United States)

    The extensive use of organophosphorus pesticides (OPs) in agriculture and domestic settings can result in widespread water contamination. The development of easy-to-use and rapid-screening immunoassay methods in a class-selective manner is a topic of considerable environmental interest. In this wo...

  16. Strip-based immunoassay for the simultaneous detection of the neonicotinoid insecticides imidacloprid and thiamethoxam in agricultural products

    Science.gov (United States)

    A semiquantitative strip immunoassay was developed for the rapid detection of imidacloprid and thiamethoxam in agricultural products using specific nanocolloidal gold-labeled monoclonal antibodies. The conjugates of imidacloprid-BSA and thiamethoxam-BSA and goat anti-mouse IgG were coated on the ni...

  17. Development of a prototype lateral flow immunoassay (LFI for the rapid diagnosis of melioidosis.

    Directory of Open Access Journals (Sweden)

    Raymond L Houghton

    2014-03-01

    Full Text Available Burkholderia pseudomallei is a soil-dwelling bacterium and the causative agent of melioidosis. Isolation of B. pseudomallei from clinical samples is the "gold standard" for the diagnosis of melioidosis; results can take 3-7 days to produce. Alternatively, antibody-based tests have low specificity due to a high percentage of seropositive individuals in endemic areas. There is a clear need to develop a rapid point-of-care antigen detection assay for the diagnosis of melioidosis. Previously, we employed In vivo Microbial Antigen Discovery (InMAD to identify potential B. pseudomallei diagnostic biomarkers. The B. pseudomallei capsular polysaccharide (CPS and numerous protein antigens were identified as potential candidates. Here, we describe the development of a diagnostic immunoassay based on the detection of CPS. Following production of a CPS-specific monoclonal antibody (mAb, an antigen-capture immunoassay was developed to determine the concentration of CPS within a panel of melioidosis patient serum and urine samples. The same mAb was used to produce a prototype Active Melioidosis Detect Lateral Flow Immunoassay (AMD LFI; the limit of detection of the LFI for CPS is comparable to the antigen-capture immunoassay (∼0.2 ng/ml. The analytical reactivity (inclusivity of the AMD LFI was 98.7% (76/77 when tested against a large panel of B. pseudomallei isolates. Analytical specificity (cross-reactivity testing determined that 97.2% of B. pseudomallei near neighbor species (35/36 were not reactive. The non-reactive B. pseudomallei strain and the reactive near neighbor strain can be explained through genetic sequence analysis. Importantly, we show the AMD LFI is capable of detecting CPS in a variety of patient samples. The LFI is currently being evaluated in Thailand and Australia; the focus is to optimize and validate testing procedures on melioidosis patient samples prior to initiation of a large, multisite pre-clinical evaluation.

  18. Plasma cortisol and 11-ketotestosterone enzyme immunoassay (EIA) kit validation for three fish species: the orange clownfish Amphiprion percula, the orangefin anemonefish Amphiprion chrysopterus and the blacktip reef shark Carcharhinus melanopterus.

    Science.gov (United States)

    Mills, S C; Mourier, J; Galzin, R

    2010-08-01

    Commercially available enzyme immunoassay (EIA) kits were validated for measuring steroid hormone concentrations in blood plasma from three fish species: the orange clownfish Amphiprion percula, the orangefin anemonefish Amphiprion chrysopterus and the blacktip reef shark Carcharhinus melanopterus. A minimum of 5 microl plasma was required to estimate hormone concentrations with both kits. These EIA kits are a simple method requiring minimal equipment, for measuring hormone profiles under field conditions.

  19. Monoclonal antibody technologies and rapid detection assays

    Science.gov (United States)

    Novel methodologies and screening strategies will be outlined on the use of hybridoma technology for the selection of antigen specific monoclonal antibodies. The development of immunoassays used for diagnostic detection of prions and bacterial toxins will be discussed and examples provided demonstr...

  20. Antibodies against interferon-beta in neuromyelitis optica patients

    DEFF Research Database (Denmark)

    Asgari, Nasrin; Kyvik, Kirsten Ohm; Steenstrup, Troels

    2014-01-01

    of IFN-neutralizing antibodies (NAbs) in 15 IFN-ß treated NMO-patients from a population-based retrospective case series cohort. NMO patients not treated with IFN-ß acted as a reference group. IFN-ß antibody determinations included binding antibodies (BAbs) measured by immunoassay and NAbs measured...... by a neutralization bioassay. Antibodies were determined 6-36 months after initiation of IFN-β therapy and NAbs additionally 5-10 years post-therapy. BAbs were detected in 14/15 NMO patients; 6/15 were NAbs-positive (3 at 5-10 years post-therapy) two of those anti-AQP4 antibody-positive; seven of the nine NAbs......, at significantly higher frequencies than NMO reference group (pneutralizing antibody status....

  1. An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads.

    Science.gov (United States)

    Tao, Xiaoqi; Jiang, Haiyang; Yu, Xuezhi; Zhu, Jinghui; Wang, Xia; Wang, Zhanhui; Niu, Lanlan; Wu, Xiaoping; Shen, Jianzhong

    2013-05-01

    A competitive, direct, chemiluminescent immunoassay based on a magnetic beads (MBs) separation and gold nanoparticles (AuNPs) labelling technique to detect chloramphenicol (CAP) has been developed. Horseradish peroxidase (HRP)-labelled anti-CAP monoclonal antibody conjugated with AuNPs and antigen-immobilized MBs were prepared. After optimization parameters of immunocomplex MBs, the IC50 values of chemiluminescence magnetic nanoparticles immunoassay (CL-MBs-nano-immunoassay) were 0.017 µg L(-1) for extract method I and 0.17 µg L(-1) for extract method II. The immunoassay with two extract methods was applied to detect CAP in milk. Comparison of these two extract methods showed that extract method I was advantageous in better sensitivity, in which the sensitivity was 10 times compared to that of extract method II, while extract method II was superior in simple operation, suitable for high throughout screen. The recoveries were 86.7-98.0% (extract method I) and 80.0-103.0% (extract method II), and the coefficients of variation (CVs) were all recovery with both extract methods and high correlation with traditional ELISA kit in milk system confirmed that the immunomagnetic assay based on AuNPs exhibited promising potential in rapid field screening for trace CAP analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Immunoassay of DNA damage

    International Nuclear Information System (INIS)

    Gasparro, F.P.; Santella, R.M.

    1988-01-01

    The direct photomodification of DNA by ultraviolet light or the photo-induced addition of exogenous compounds to DNA components results in alterations of DNA structure ranging from subtle to profound. There are two consequences of these conformational changes. First, cells in which the DNA has been damaged are capable of executing repair steps. Second, the DNA which is usually of very low immunogenicity now becomes highly antigenic. This latter property has allowed the production of a series of monoclonal antibodies that recognize photo-induced DNA damage. Monoclonal antibodies have been generated that recognize the 4',5'-monoadduct and the crosslink of 8-methoxypsoralen in DNA. In addition, another antibody has been prepared which recognizes the furan-side monoadduct of 6,4,4'-trimethylangelicin in DNA. These monoclonal antibodies have been characterized as to sensitivity and specificity using non-competitive and competitive enzyme-linked-immunosorbent assays (ELISA). (author)

  3. Immunoassay of DNA damage

    Energy Technology Data Exchange (ETDEWEB)

    Gasparro, F P; Santella, R M

    1988-09-01

    The direct photomodification of DNA by ultraviolet light or the photo-induced addition of exogenous compounds to DNA components results in alterations of DNA structure ranging from subtle to profound. There are two consequences of these conformational changes. First, cells in which the DNA has been damaged are capable of executing repair steps. Second, the DNA which is usually of very low immunogenicity now becomes highly antigenic. This latter property has allowed the production of a series of monoclonal antibodies that recognize photo-induced DNA damage. Monoclonal antibodies have been generated that recognize the 4',5'-monoadduct and the crosslink of 8-methoxypsoralen in DNA. In addition, another antibody has been prepared which recognizes the furan-side monoadduct of 6,4,4'-trimethylangelicin in DNA. These monoclonal antibodies have been characterized as to sensitivity and specificity using non-competitive and competitive enzyme-linked-immunosorbent assays (ELISA).

  4. Egg yolk antibodies for detection and neutralization of Clostridium botulinum type A neurotoxin.

    Science.gov (United States)

    Trott, D L; Yang, M; Gonzalez, J; Larson, A E; Tepp, W H; Johnson, E A; Cook, M E

    2009-05-01

    The objective of this research project was to determine the usefulness of an egg antibody platform for producing materials for the detection and neutralization of botulinum type A neurotoxin. Yield estimates for detection and neutralizing antibodies produced using methods described were calculated. Antibody specific to botulinum toxoid A (aToxoid) and toxin A (aBoNT/A) was produced by immunizing hens with botulinum toxoid A (toxoid) followed by increasing amounts of botulinum neurotoxin A (BoNT/A) in Freund incomplete adjuvant. Egg yolks were extracted with polyethylene glycol (PEG) for antibody detection and neutralization experiments. A model aToxoid/toxoid immunoassay using only egg yolk antibody was developed and had a detection limit of 1 pg/ml of toxoid. In an indirect enzyme-linked immunosorbent assay of BoNT/A-specific antibody, the aBoNT/A contained more BoNT/A-specific antibody than did the aToxoid, and aBoNT/A was as effective as commercial rabbit antibody. The aToxoid provided no protection against BoNT/A in a standard mouse neutralization assay; however, 1 mg of PEG-extracted aBoNT/A neutralized 4,000 lethal doses of BoNT/A injected intraperitoneally. Based on these results, we calculated that in 1 month one hen could produce more than 100 liters of antibody detection reagents or enough antibody to neutralize approximately 11.6 million mouse lethal doses of botulinum toxin. Utilization of an egg antibody platform is potentially rapid (28 to 70 days) and scalable to kilogram quantities using current egg production facilities with as few as 1,000 hens.

  5. Enzyme-linked immunosorbent Assay for detecting of antibody to canine distemper virus

    Directory of Open Access Journals (Sweden)

    Sudarisman

    2006-03-01

    Full Text Available Serum neutralisation test (SNT has been established for evaluating canine distemper vaccination, but until now SNT was rarely used due to the need for continuous tissue culture facilities and requires 3 days to perform. For detecting antibody to canine distemper virus, an enzyme-linked immunosorbent assay (ELISA is relatively simple and rapid seroassay. ELISA for canine immunoglobulin (Ig G antibodies to canine distemper virus (CDV was developed by using Onderstepoort strain of canine distemper virus as coating antigen. Rabbit anti canine IgG labelled with horse radish peroxidase was used as the conjugate, while phenylenediamine dihydrochloride (OPD was used as the substrate. The ELISA results were then compared with the results of the SNT, using the sera of 312 random-source dogs from West Java. The two test-results had a high degree of correlation. Very few discrepancies occurred and most of these were at the lower limits of each test. When the sera were tested at 1 : 100 dilutions, there was a 95.5% agreement between the ELISA and SNT. Their sensitivity and spesificity were 83.9 and 98.4%. Titrated SNT and ELISA also were performed on sera from 7 dogs whose lifetime medical histories were known. The antibodies were inclining up after two months of post vaccination, where the titre was not in zero/lower position at the day of vaccination. However, antibody zero or low position were found at 28 days post vaccination. All of the results indicated that ELISA can be used for evaluating antibody to canine distemper virus response, replacing the SNT.

  6. A Recombinant Secondary Antibody Mimic as a Target-specific Signal Amplifier and an Antibody Immobilizer in Immunoassays.

    Science.gov (United States)

    Min, Junseon; Song, Eun Kyung; Kim, Hansol; Kim, Kyoung Taek; Park, Tae Joo; Kang, Sebyung

    2016-04-11

    We construct a novel recombinant secondary antibody mimic, GST-ABD, which can bind to the Fc regions of target-bound primary antibodies and acquire multiple HRPs simultaneously. We produce it in tenth of mg quantities with a bacterial overexpression system and simple purification procedures, significantly reducing the manufacturing cost and time without the use of animals. GST-ABD is effectively conjugated with 3 HRPs per molecule on an average and selectively bind to the Fc region of primary antibodies derived from three different species (mouse, rabbit, and rat). HRP-conjugated GST-ABD (HRP-GST-ABD) is successfully used as an alternative to secondary antibodies to amplify target-specific signals in both ELISA and immunohistochemistry regardless of the target molecules and origin of primary antibodies used. GST-ABD also successfully serves as an anchoring adaptor on the surface of GSH-coated plates for immobilizing antigen-capturing antibodies in an orientation-controlled manner for sandwich-type indirect ELISA through simple molecular recognition without any complicated chemical modification.

  7. Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays

    Directory of Open Access Journals (Sweden)

    John Miller

    2015-04-01

    Full Text Available We report use of U-shaped biconically tapered optical fibers (BTOF as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G-antigen (rabbit anti-mouse IgG reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method.

  8. Application of a newly developed high-sensitivity HBsAg chemiluminescent enzyme immunoassay for hepatitis B patients with HBsAg seroclearance.

    Science.gov (United States)

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-11-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstrated seroclearance by the Abbott Architect assay. The performance of the Lumipulse HBsAg-HQ assay was compared with that of a quantitative HBsAg detection system (Abbott Architect) and the Roche Cobas TaqMan HBV DNA assay (CTM) (lower limit of detection, 2.1 log copies/ml) using blood serum samples from patients who were determined to be HBsAg seronegative by the Abbott Architect assay. Ten patients had spontaneous HBsAg loss. Of 8 patients treated with nucleotide analogues (NAs), two were HBsAg seronegative after stopping lamivudine therapy and 6 were HBsAg seronegative during entecavir therapy. Eight acute hepatitis B (AH) patients became HBsAg seronegative. Of the 26 patients, 16 were HBsAg positive by the Lumipulse HBsAg-HQ assay but negative by the Abbott Architect assay. The differences between the two assays in terms of detectable HBsAg persisted over the long term in the spontaneous loss group (median, 10 months), the NA-treated group (2.5 months), and the AH group (0.5 months). In 9 patients, the Lumipulse HBsAg-HQ assay detected HBsAg when HBV DNA was negative by the CTM assay. HBsAg was also detected by the Lumipulse HBsAg-HQ assay in 4 patients with an anti-HBs concentration of >10 mIU/ml, 3 of whom had no HBsAg escape mutations. The automatic, highly sensitive HBsAg CLEIA Lumipulse HBsAg-HQ is a convenient and precise assay for HBV monitoring.

  9. Rheumatoid factor interference in immunogenicity assays for human monoclonal antibody therapeutics.

    Science.gov (United States)

    Tatarewicz, Suzanna; Miller, Jill M; Swanson, Steven J; Moxness, Michael S

    2010-05-31

    Rheumatoid factors (RFs) are endogenous human antibodies that bind to human gamma globulins. RFs demonstrate preferential binding to aggregated gamma globulins and are involved in the clearing mechanism of immune complexes. Immunoassays designed to measure human anti-human antibodies (HAHA) after administration of monoclonal antibody therapeutics are thus vulnerable to interference from RFs. When using a sensitive electrochemiluminescent (ECL) bridging immunoassay, samples from subjects with rheumatoid arthritis demonstrated much higher baseline reactivity than healthy subjects. Interference was found to be dependent on the aggregation state of the therapeutic antibody that had been conjugated with the detection reagent (ruthenium). Size exclusion high performance liquid chromatography (SE-HPLC) demonstrated that of the total integrated peaks, as little as 0.55% high molecular weight aggregates (>600kDa) were sufficient to cause increased reactivity. Stability studies of the ruthenium and biotin conjugated therapeutic antibody indicated that storage time, temperature and buffer formulation were critical in maintaining the integrity of the reagents. Through careful SE-HPLC monitoring we were able to choose appropriate storage and buffer conditions which led to a reduction in the false reactivity rate in therapeutic-naïve serum from a rheumatoid arthritis population.

  10. Development of an immunomagnetic bead-based time-resolved fluorescence immunoassay for rapid determination of levels of carcinoembryonic antigen in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Hou Jingyuan; Liu Tiancai; Lin Guanfeng; Li Zhixiong; Zou Liping; Li Ming [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515 (China); Wu Yingsong, E-mail: wg@fimmu.com [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515 (China)

    2012-07-13

    Highlights: Black-Right-Pointing-Pointer Magnetic beads was used as the solid phase for TRFIA. Black-Right-Pointing-Pointer The linearity range was broadened greatly compared with conventional TRFIA method. Black-Right-Pointing-Pointer The analysis time was significantly shorter compared with conventional TRFIA method. Black-Right-Pointing-Pointer This method could be developed for practical clinical detections of tumor-associated antigens. - Abstract: A novel immunoassay for the determination of tumor markers in human serum was established by combining a time-resolved fluoroimmunoassay (TRFIA) and immunomagnetic separation. Based on a sandwich-type immunoassay format, analytes in samples were captured by magnetic beads coated with one monoclonal antibody and 'sandwiched' by another monoclonal antibody labeled with europium chelates. The immunocomplex was separated and washed by exposure to a magnetic field and treatment with enhancement solution; fluorescence was then measured according to the number of europium ions dissociated. Levels of the model analyte, carcinoembryonic antigen (CEA), were determined in a linear range (1-1000 ng mL{sup -1}) with a limit of detection of 0.5 ng mL{sup -1} under optimal conditions. The reproducibility, recovery, and specificity of the immunoassay were demonstrated to be acceptable. To evaluate this novel assay for clinical applications, 239 serum samples were evaluated. Compared with the conventional TRFIA and chemiluminescence immunoassay (CLIA), the correlation coefficients of the developed immunoassay were 0.985 and 0.975, respectively. These results showed good correlation and confirmed that our method is feasible and could be used for the clinical determination of CEA (or other tumor antigens) in human serum.

  11. Assay of anti-HBs antibodies using a recombinant antigen and latex particle counting: comparison with five commercial tests.

    Science.gov (United States)

    Galanti, L M; Cornu, C; Masson, P L; Robert, A R; Becheanu, D; Lamy, M E; Cambiaso, C L

    1991-05-01

    An assay of anti-HBs antibodies based on agglutination of latex particles coated with recombinant HBs-antigen was compared with Abbott radioimmunoassay (Abbott-RIA), which uses a human plasma-derived antigen. The population examined consisted of 76 Abbott-RIA anti-HBs-negative prevaccinated subjects and 1044 serum samples anti-HBs found positive by Abbott-RIA, including 283 samples of subjects vaccinated either with a human plasma-derived vaccine (group A; n = 180) or with a recombinant vaccine (group B; n = 103). Correlation coefficients between the two techniques were respectively r = 0.89 for the whole population (n = 1044), r = 0.98 in group A and r = 0.74 in group B. Anti-HBs titres were higher with latex than with RIA in group B as shown by the regression slopes: latex = 508 + 1.11 RIA in group A and latex = -1138 + 3.97 RIA in group B, suggesting that some vaccinated subjects from group B produced antibodies against epitopes proper to the recombinant antigen. In the prevaccinated population and in group A, the latex results were compared with those of radioimmunoassays (Abbott, Sorin) and enzyme immunoassays (Behring, Roche, Pasteur). Only the Roche-EIA detected anti-HBs in the prevaccinated subjects. The correlation between the various immunoassays was r greater than 0.96 only for values higher than 100 IU/l.

  12. Identification of a Vesicular-Arbuscular Mycorrhizal Fungus by Using Monoclonal Antibodies in an Enzyme-Linked Immunosorbent Assay †

    OpenAIRE

    Wright, Sara F.; Morton, Joseph B.; Sworobuk, Janis E.

    1987-01-01

    Spore morphology is currently used to identify species of vesicular-arbuscular mycorrhizal fungi. We report the first use of a highly specific immunological method for identification of a vesicular-arbuscular mycorrhizal fungus. Two monoclonal antibodies were produced against Glomus occultum. Monoclonal antibodies reacted strongly with both spores and hyphae in an indirect enzyme-linked immunosorbent assay. All other mycorrhizal (29 species) and nonmycorrhizal (5 species) fungi tested were no...

  13. Polyethylene imine/graphene oxide layer-by-layer surface functionalization for significantly improved limit of detection and binding kinetics of immunoassays on acrylate surfaces.

    Science.gov (United States)

    Miyazaki, Celina M; Mishra, Rohit; Kinahan, David J; Ferreira, Marystela; Ducrée, Jens

    2017-10-01

    Antibody immobilization on polymeric substrates is a key manufacturing step for microfluidic devices that implement sample-to-answer automation of immunoassays. In this work, a simple and versatile method to bio-functionalize poly(methylmethacrylate) (PMMA), a common material of such "Lab-on-a-Chip" systems, is proposed; using the Layer-by-Layer (LbL) technique, we assemble nanostructured thin films of poly(ethylene imine) (PEI) and graphene oxide (GO). The wettability of PMMA surfaces was significantly augmented by the surface treatment with (PEI/GO) 5 film, with an 81% reduction of the contact angle, while the surface roughness increased by 600%, thus clearly enhancing wettability and antibody binding capacity. When applied to enzyme-linked immunosorbent assays (ELISAs), the limit of detection of PMMA surface was notably improved from 340pgmL -1 on commercial grade polystyrene (PS) and 230pgmL -1 on plain PMMA surfaces to 130pgmL -1 on (PEI/GO) 5 treated PMMA. Furthermore, the accelerated antibody adsorption kinetics on the LbL films of GO allowed to substantially shorten incubation times, e.g. for anti-rat IgG adsorption from 2h down to 15min on conventional and treated surfaces, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Anti-dog IgG secondary antibody successfully detects IgG in a variety of aquatic mammals

    Science.gov (United States)

    Roehl, Katherine; Jankowski, Mark D.; Hofmeister, Erik K.

    2016-01-01

    Serological tests play an important role in the detection of wildlife diseases. However, while there are many commercial assays and reagents available for domestic species, there is a need to develop efficient serological assays for wildlife. In recent years, marine mammals have represented a wildlife group with emerging infectious diseases, such as influenza, brucellosis, and leptospirosis. However, with the exception of disease-agent-specific assays or functional assays, few reports describe the use of antibody detection assays in marine mammals. In an indirect enzyme-linked immunoassay (EIA) or an immunofluorescence assay, antibody is detected using an antitarget species secondary conjugated antibody. The sensitivity of the assay depends on the avidity of the binding reaction between the bound antibody and the detection antibody. A commercial polyclonal antidog IgG conjugated antibody was tested in an EIA for its ability to sensitively detect the IgG of seven marine mammals including sea otter (Enhydra lutris), polar bear (Ursus maritimus), grey seal (Halichoerus grypus), harbor seal (Phoca vitulina), northern elephant seal (Mirounga angustirostris), California sea lion (Zalophus californianus), Pacific walrus (Odobenus rosmarus) and one freshwater mammal: Asian small-clawed otter (Aonyx cinerea). With the exception of Asian small-clawed sea otters, the detection of IgG in these marine mammals either exceeded or was nearly equal to detection of dog IgG. The use of the tested commercial antidog IgG antibody may be a valid approach to the detection of antibody response to disease in sea mammals.

  15. Discerning Silk Produced by Bombyx mori from Those Produced by Wild Species Using an Enzyme-Linked Immunosorbent Assay Combined with Conventional Methods.

    Science.gov (United States)

    You, Qiushi; Li, Qingqing; Zheng, Hailing; Hu, Zhiwen; Zhou, Yang; Wang, Bing

    2017-09-06

    Recently, much interest has been paid to the separation of silk produced by Bombyx mori from silk produced by other species and tracing the beginnings of silk cultivation from wild silk exploitation. In this paper, significant differences between silks from Bombyx mori and other species were found by microscopy and spectroscopy, such as morphology, secondary structure, and amino acid composition. For further accurate identification, a diagnostic antibody was designed by comparing the peptide sequences of silks produced by Bombyx mori and other species. The results of the noncompetitive indirect enzyme-linked immunosorbent assay (ELISA) indicated that the antibody that showed good sensitivity and high specificity can definitely discern silk produced by Bombyx mori from silk produced by wild species. Thus, the antibody-based immunoassay has the potential to be a powerful tool for tracing the beginnings of silk cultivation. In addition, combining the sensitive, specific, and convenient ELISA technology with other conventional methods can provide more in-depth and accurate information for species identification.

  16. Specific binding of antigen-antibody in physiological environments: Measurement, force characteristics and analysis

    Science.gov (United States)

    Gu, Xin; Zhou, Jun; Zhou, Lu; Xie, Shusen; Petti, Lucia; Wang, Shaomin; Wang, Fuyan

    2018-05-01

    The specific recognition of the antigen by the antibody is the crucial step in immunoassays. Measurement and analysis of the specific recognition, including the ways in which it is influenced by external factors are of paramount significance for the quality of the immunoassays. Using prostate-specific antigen (PSA)/anti-PSA antibody and α-fetoprotein (AFP) /anti-AFP antibody as examples, we have proposed a novel solution for measuring the binding forces between the antigens and their corresponding antibodies in different physiological environments by combining laminar flow control technology and optical tweezers technology. On the basis of the experimental results, the different binding forces of PSA/anti-PSA antibody and AFP/anti-AFP antibody in the same phosphate-buffered saline (PBS) environments are analysed by comparing the affinity constant of the two antibodies and the number of antigenic determinants of the two antigens. In different electrolyte environments, the changes of the binding force of antigens-antibodies are explained by the polyelectrolyte effect and hydrophobic interaction. Furthermore, in different pH environments, the changes of binding forces of antigens-antibodies are attributed to the role of the denaturation of protein. The study aims to recognise the antigen-antibody immune mechanism, thus ensuring further understanding of the biological functions of tumour markers, and it promises to be very useful for the clinical diagnosis of early-stage cancer.

  17. A harmonized immunoassay with liquid chromatography-mass spectrometry analysis in egg allergen determination.

    Science.gov (United States)

    Nimata, Masaomi; Okada, Hideki; Kurihara, Kei; Sugimoto, Tsukasa; Honjoh, Tsutomu; Kuroda, Kazuhiko; Yano, Takeo; Tachibana, Hirofumi; Shoji, Masahiro

    2018-01-01

    Food allergy is a serious health issue worldwide. Implementing allergen labeling regulations is extremely challenging for regulators, food manufacturers, and analytical kit manufacturers. Here we have developed an "amino acid sequence immunoassay" approach to ELISA. The new ELISA comprises of a monoclonal antibody generated via an analyte specific peptide antigen and sodium lauryl sulfate/sulfite solution. This combination enables the antibody to access the epitope site in unfolded analyte protein. The newly developed ELISA recovered 87.1%-106.4% ovalbumin from ovalbumin-incurred model processed foods, thereby demonstrating its applicability as practical egg allergen determination. Furthermore, the comparison of LC-MS/MS and the new ELISA, which targets the amino acid sequence conforming to the LC-MS/MS detection peptide, showed a good agreement. Consequently the harmonization of two methods was demonstrated. The complementary use of the new ELISA and LC-MS analysis can offer a wide range of practical benefits in terms of easiness, cost, accuracy, and efficiency in food allergen analysis. In addition, the new assay is attractive in respect to its easy antigen preparation and predetermined specificity. Graphical abstract The ELISA composing of the monoclonal antibody targeting the amino acid sequence conformed to LC-MS detection peptide, and the protein conformation unfolding reagent was developed. In ovalbumin determination, the developed ELISA showed a good agreement with LC-MS analysis. Consequently the harmonization of immunoassay with LC-MS analysis by using common target amino acid sequence was demonstrated.

  18. A Homogeneous Time-Resolved Fluorescence Immunoassay Method for the Measurement of Compound W.

    Science.gov (United States)

    Huang, Biao; Yu, Huixin; Bao, Jiandong; Zhang, Manda; Green, William L; Wu, Sing-Yung

    2018-01-01

    Using compound W (a 3,3'-diiodothyronine sulfate [T 2 S] immuno-crossreactive material)-specific polyclonal antibodies and homogeneous time-resolved fluorescence immunoassay assay techniques (AlphaLISA) to establish an indirect competitive compound W (ICW) quantitative detection method. Photosensitive particles (donor beads) coated with compound W or T 2 S and rabbit anti-W antibody were incubated with biotinylated goat anti-rabbit antibody. This constitutes a detection system with streptavidin-coated acceptor particle. We have optimized the test conditions and evaluated the detection performance. The sensitivity of the method was 5 pg/mL, and the detection range was 5 to 10 000 pg/mL. The intra-assay coefficient of variation averages W levels in extracts of maternal serum samples. This may have clinical application to screen congenital hypothyroidism in utero.

  19. Excess antibody immunoassays for rat glandular kallikreins. Measurement of kallikrein from different organs in the presence of cross-reacting antigens

    International Nuclear Information System (INIS)

    Johansen, L.; Oerstavik, T.B.; Holck, M.; Nustad, K.

    1983-01-01

    An immunoradiometric assay has previously been developed for measurement of rat glandular kallikrein. In the present paper, further studies on the specificity and sensitivity of the method are described. Problems of interference of immunologically cross-reacting antigens were overcome by proper preabsorption of the antibody. A method was thus established in which enzymatic activity of the immunoreactive kallikrein could be measured even in the presence of enzymes sharing immunological determinants and substrate specificity with kallikrein. Two variants of the immunoradiometric assay have been evaluated. A simplified version with simultaneous addition of all reagents gave results equal to those obtained in the original assay. A further modification with delayed addition of the solid-phase antibody, gave considerable improvement in assay sensitivity. (Auth.)

  20. Chemically Regulated ROS Generation from Gold Nanoparticles for Enzyme-Free Electrochemiluminescent Immunosensing.

    Science.gov (United States)

    Higashi, Yui; Mazumder, Joyotu; Yoshikawa, Hiroyuki; Saito, Masato; Tamiya, Eiichi

    2018-04-17

    In the present work, we report on an enzyme-free electrochemiluminescent (ECL) immunosensing scheme utilizing the catalytic generation of reactive oxygen species (ROS) from gold nanoparticles (AuNPs) (diameter ≥5 nm) dispersed in aqueous solutions of trishydroxymethylaminomethane (Tris). First, to examine this catalytic pathway in detail, the effects of various factors such as the AuNP size and concentration, dispersant type and concentration, and dissolved oxygen were investigated using the electrochemiluminescence (ECL) of luminol. It was found that the catalytic generation of ROS from AuNPs can be regulated chemically by altering conditions such as the type, concentration, and pH of the solution that the AuNPs are dispersed in. Under the best conditions studied in this work, the AuNPs displayed high catalytic activity toward ROS generation, with an estimated apparent turnover number per AuNP of 0.1 s -1 , comparable to those of several common peroxide-producing enzymes. Following these studies, this phenomenon was applied to develop a one-step enzyme-free ECL immunosensor based on sandwiching the target analyte using antibody-conjugated magnetic beads (MB) and AuNPs. Using IgA as a model analyte, the developed immunosensor was able to detect the target in the range of 1 ng/mL to 10 μg/mL, with the lower detection limit being comparable to those of commercial assays for the same target. Altering the antibodies used to modify the MB and AuNPs could further improve the detection limit as well as expand the applicability of this immunoassay to the detection of other analytes.

  1. FY1995 development of a novel rapid immunoassay technology; 1995 nendo shinkina kosoku men'eki sokutei gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    By utilizing the phenomenon that the antigen induces association of VH and VL, which are the antigen-recognizing fragments of antibody, develop a novel rapid immunoassay technology which will eliminate the defects of conventional immunoassays, such as long measuring time and requirement of expensive large automated apparatus. In addition, develop a methodology to make Fvs with low VH-VL affinity but that associate tightly in the presence of antigen. Using a model anti-hen egg lysozyme antibody HyHEL-10 Fv and BlAcore, we have clarified the kinetic basis of the Fv stabilization by HEL. By labeling HyHEL-10 VH, VL with succinimide esters of fluorescein and tetramethylrhodamin, respectively, at their N-termini, we could successfully detect VH-VL association by the increment of fluorescence resonance energy transfer. As a result, 1 {mu} g/ml of antigen could be detected homogeneously in less than 5 minutes. Some VH-VL association measurement systems were made by utilizing M13 phage display of VH fragments of HyHEL-10, anti-nitrophenacetyl, anti-digoxin antibodies. (NEDO)

  2. Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes.

    Science.gov (United States)

    Wei, Hui; Wang, Erkang

    2013-07-21

    Over the past few decades, researchers have established artificial enzymes as highly stable and low-cost alternatives to natural enzymes in a wide range of applications. A variety of materials including cyclodextrins, metal complexes, porphyrins, polymers, dendrimers and biomolecules have been extensively explored to mimic the structures and functions of naturally occurring enzymes. Recently, some nanomaterials have been found to exhibit unexpected enzyme-like activities, and great advances have been made in this area due to the tremendous progress in nano-research and the unique characteristics of nanomaterials. To highlight the progress in the field of nanomaterial-based artificial enzymes (nanozymes), this review discusses various nanomaterials that have been explored to mimic different kinds of enzymes. We cover their kinetics, mechanisms and applications in numerous fields, from biosensing and immunoassays, to stem cell growth and pollutant removal. We also summarize several approaches to tune the activities of nanozymes. Finally, we make comparisons between nanozymes and other catalytic materials (other artificial enzymes, natural enzymes, organic catalysts and nanomaterial-based catalysts) and address the current challenges and future directions (302 references).

  3. Proximity hybridization-regulated catalytic DNA hairpin assembly for electrochemical immunoassay based on in situ DNA template-synthesized Pd nanoparticles

    International Nuclear Information System (INIS)

    Zhou, Fuyi; Yao, Yao; Luo, Jianjun; Zhang, Xing; Zhang, Yu; Yin, Dengyang; Gao, Fenglei; Wang, Po

    2017-01-01

    Novel hybridization proximity-regulated catalytic DNA hairpin assembly strategy has been proposed for electrochemical immunoassay based on in situ DNA template-synthesized Pd nanoparticles as signal label. The DNA template-synthesized Pd nanoparticles were characterized with atomic force microscopic and X-ray photoelectron spectroscopy. The highly efficient electrocatalysis by DNA template synthesized Pd nanoparticles for NaBH 4 oxidation produced an intense detection signal. The label-free electrochemical method achieved the detection of carcinoembryonic antigen (CEA) with a linear range from 10 −15 to 10 −11  g mL −1 and a detection limit of 0.43 × 10 −15  g mL −1 . Through introducing a supersandwich reaction to increase the DNA length, the electrochemical signal was further amplified, leading to a detection limit of 0.52 × 10 −16  g mL −1 . And it rendered satisfactory analytical performance for the determination of CEA in serum samples. Furthermore, it exhibited good reproducibility and stability; meanwhile, it also showed excellent specificity due to the specific recognition of antigen by antibody. Therefore, the DNA template synthesized Pd nanoparticles based signal amplification approach has great potential in clinical applications and is also suitable for quantification of biomarkers at ultralow level. - Graphical abstract: A novel label-free and enzyme-free electrochemical immunoassay based on proximity hybridization-regulated catalytic DNA hairpin assemblies for recycling of the CEA. - Highlights: • A novel enzyme-free electrochemical immunosensor was developed for detection of CEA. • The signal amplification was based on catalytic DNA hairpin assembly and DNA-template-synthesized Pd nanoparticles. • The biosensor could detect CEA down to 0.52 × 10 −16  g mL −1 level with a dynamic range spanning 5 orders of magnitude.

  4. Direct analysis of airborne mite allergen (Der f1) in the residential atmosphere by chemifluorescent immunoassay using bioaerosol sampler.

    Science.gov (United States)

    Miyajima, Kumiko; Suzuki, Yurika; Miki, Daisuke; Arai, Moeka; Arakawa, Takahiro; Shimomura, Hiroji; Shiba, Kiyoko; Mitsubayashi, Kohji

    2014-06-01

    Dermatophagoides farinae allergen (Der f1) is one of the most important indoor allergens associated with allergic diseases in humans. Mite allergen Der f1 is usually associated with particles of high molecular weight; thus, Der f1 is generally present in settled dust. However, a small quantity of Der f1 can be aerosolized and become an airborne component. Until now, a reliable method of detecting airborne Der f1 has not been developed. The aim of this study was to develop a fiber-optic chemifluorescent immunoassay for the detection of airborne Der f1. In this method, the Der f1 concentration measured on the basis of the intensity of fluorescence amplified by an enzymatic reaction between the labeled enzyme by a detection antibody and a fluorescent substrate. The measured Der f1 concentration was in the range from 0.49 to 250 ng/ml and a similar range was found by enzyme-linked immunosorbent assay (ELISA). This method was proved to be highly sensitive to Der f1 compared with other airborne allergens. For the implementation of airborne allergen measurement in a residential environment, a bioaerosol sampler was constructed. The airborne allergen generated by a nebulizer was conveyed to a newly sampler we developed for collecting airborne Der f1. The sampler was composed of polymethyl methacrylate (PMMA) cells for gas/liquid phases and some porous membranes which were sandwiched in between the two phases. Der f1 in air was collected by the sampler and measured using the fiber-optic immunoassay system. The concentration of Der f1 in aerosolized standards was in the range from 0.125 to 2.0 mg/m(3) and the collection rate of the device was approximately 0.2%. © 2013 Elsevier B.V. All rights reserved.

  5. Current status and future developments in radiolabelled immunoassays

    International Nuclear Information System (INIS)

    Edwards, R.

    1998-01-01

    Radioisotopes are used extensively in medical practice and their use in RIA or IRMA usually represent a small proportion of the total. Radiolabelled immunoassays based on 125 I constitute a simple didactic, cost effective and robust technology which is still regarded as the reference method in many clinical applications. The IAEA has implemented many successful programmes using the ''bulk reagent'' approach, involving 68 countries in all the different regions. The main achievements have been in technology transfer with self sufficiency in production for some countries; training of large numbers of staff; quality control and quality assurance schemes; devolution of screening programmes for neonatal congenital hypothryoidism. Alternatives to the use of radioisotopic tracers are constrained by many factors and are often only available in restricted commercial packages. They are often not suitable for technology transfer programmes and often lack any didactic component in addition to a relative high cost. The production of radiolabels using 125 I is both simple and adaptable. In addition expertise in their preparation and purification is widespread even in developing countries. Together with the ease of producing antibodies, the facts have made 125 I-radiolabelled immunoassays ideal for investigative procedures for many research activities (30,31) particularly in the medical context where radioisotopes are commonly used. In conclusion, even a superficial examination of public health statistics for various countries throughout the continents indicates a need for a simple, inexpensive and robust analytical tool. In this light, there is a predicted continuing role for radiolabelled immunoassays. (author)

  6. Differentiation of ruminal bacterial species by enzyme-linked immunosorbent assay using egg yolk antibodies from immunized chicken hens.

    OpenAIRE

    Ricke, S C; Schaefer, D M; Cook, M E; Kang, K H

    1988-01-01

    Cross-reactivity among four species of ruminal bacteria was examined by using egg yolk antibodies from immunized Leghorn laying hens and an enzyme-linked-immunosorbent assay. The effects of the four species on the hens were compared on various days postimmunization. Hens injected with the same bacterial species had similar apparent antibody levels over the entire postimmunization period, but only Bacteroides ruminicola B1(4) and Selenomonas ruminantium D antigens elicited early increases in a...

  7. Evaluation of the FIDIS vasculitis multiplex immunoassay for diagnosis and follow-up of ANCA-associated vasculitis and Goodpasture's disease

    NARCIS (Netherlands)

    Damoiseaux, J.; Vaessen, M.; Knapen, Y.; Csernok, E.; Stegeman, C. A.; Van Paassen, P.; Tervaert, J. W. Cohen; Gershwin, ME; Shoenfeld, Y

    2007-01-01

    We have evaluated a new-multiplex immunoassay (FIDIS Vasculitis) for simultaneous detection and quantification of anti-MPO, -PR3, and -glomerular basement membrane (GBM) antibodies in diagnosis and follow-up of ANCA-associated vasculitides (AAV) and Goodpasture's disease. ANCA were determined in

  8. Antibody screening by enzyme-linked immunosorbent assay using pooled soluble HLA in renal transplant candidates.

    Science.gov (United States)

    Zaer, F; Metz, S; Scornik, J C

    1997-01-15

    The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.

  9. Monoclonal antibodies specific to heat-treated porcine blood.

    Science.gov (United States)

    Raja Nhari, Raja Mohd Hafidz; Hamid, Muhajir; Rasli, Nurmunirah Mohamad; Omar, Abdul Rahman; El Sheikha, Aly Farag; Mustafa, Shuhaimi

    2016-05-01

    Porcine blood is potentially being utilized in food as a binder, gelling agent, emulsifier or colorant. However, for certain communities, the usage of animal blood in food is strictly prohibited owing to religious concerns and health reasons. This study reports the development of monoclonal antibodies (MAbs) against heat-treated soluble proteins (HSPs) of autoclaved porcine blood; characterization of MAbs against blood, non-blood and plasma from different animal species using qualitative indirect non-competitive enzyme-linked immunosorbent assay (ELISA); and immunoblotting of antigenic components in HSPs of porcine blood. Fifteen MAbs are specific to heat-treated and raw porcine blood and not cross-reacted with other animal blood and non-blood proteins (meat and non-meat). Twelve MAbs are specific to porcine plasma, while three MAbs specific to porcine plasma are cross-reacted with chicken plasma. Immunoblotting revealed antigenic protein bands (∼60, ∼85-100 and ∼250 kDa) in porcine blood and plasma recognized by the MAbs. Selection of MAbs that recognized 60 kDa HSPs of porcine blood and plasma as novel monoclonal antibodies would be useful for detection of porcine plasma in processed food using the immunoassay method. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  10. Nanobody-based electrochemical immunoassay for Bacillus thuringiensis Cry1Ab toxin by detecting the enzymatic formation of polyaniline

    International Nuclear Information System (INIS)

    Zhu, Min; Li, Guanghui; Li, Min; Zhou, Zikai; Liu, Hong; Lei, Hongtao; Shen, Yanfei; Wan, Yakun

    2015-01-01

    We describe an electrochemical immunoassay for the Cry1Ab toxin that is produced by Bacillus thuringiensis. It is making use of a nanobody (a heavy-chain only antibody) that was selected from an immune phage displayed library. A biotinylated primary nanobody and a HRP-conjugated secondary nanobody were applied in a sandwich immunoassay where horseradish peroxidase (HRP) is used to produce polyaniline (PANI) from aniline. PANI can be easily detected by differential pulse voltammetry at a working voltage as low as 40 mV (vs. Ag/AgCl) which makes the assay fairly selective. This immunoassay for Cry1Ab has an analytical range from 0.1 to 1000 ng∙mL -1 and a 0.07 ng∙mL -1 lower limit of detection. The average recoveries of the toxin from spiked samples are in the range from 102 to 114 %, with a relative standard deviation of <7.5 %. The results demonstrated that the assay represented an attractive alternative to existing immunoassays in enabling affordable, sensitive, robust and specific determination of this toxin. (author)

  11. Evaluation of a competitive enzyme-linked immunosorbent assay for measurements of soluble HLA-G protein.

    Science.gov (United States)

    Rasmussen, M; Dahl, M; Buus, S; Djurisic, S; Ohlsson, J; Hviid, T V F

    2014-08-01

    The human leukocyte antigen (HLA) class Ib molecule, HLA-G, has gained increased attention because of its assumed important role in immune regulation. The HLA-G protein exists in several soluble isoforms. Most important are the actively secreted HLA-G5 full-length isoform generated by alternative splicing retaining intron 4 with a premature stop codon, and the cleavage of full-length membrane-bound HLA-G1 from the cell surface, so-called soluble HLA-G1 (sHLA-G1). A specific and sensitive immunoassay for measurements of soluble HLA-G is mandatory for conceivable routine testing and research projects. We report a novel method, a competitive immunoassay, for measuring HLA-G5/sHLA-G1 in biological fluids. The sHLA-G immunoassay is based upon a competitive enzyme-linked immunosorbent assay (ELISA) principle. It includes a recombinant sHLA-G1 protein in complex with β2-microglobulin and a peptide as a standard, biotinylated recombinant sHLA-G1 as an indicator, and the MEM-G/9 anti-HLA-G monoclonal antibody (mAb) as the capture antibody. The specificity and sensitivity of the assay were evaluated. Testing with different recombinant HLA class I proteins and different anti-HLA class I mAbs showed that the sHLA-G immunoassay was highly specific. Optimal combinations of competitor sHLA-G1 and capture mAb concentrations were determined. Two versions of the assay were tested. One with a relatively wide dynamic range from 3.1 to 100.0 ng/ml, and another more sensitive version ranging from 1.6 to 12.5 ng/ml. An intra-assay coefficient of variation (CV) of 15.5% at 88 ng/ml and an inter-assay CV of 23.1% at 39 ng/ml were determined. An assay based on the competitive sHLA-G ELISA may be important for measurements of sHLA-G proteins in several conditions: assisted reproduction, organ transplantation, cancer, and certain pregnancy complications, both in research studies and possibly in the future also for clinical routine use. © 2014 John Wiley & Sons A/S. Published by John Wiley

  12. Bispecific antibodies and their use in applied research

    Directory of Open Access Journals (Sweden)

    Harshit Verma

    Full Text Available Bispecific antibodies (BsAb can, by virtue of combining two binding specificities, improve the selectivity and efficacy of antibody-based treatment of human disease. Antibodies with two distinct binding specificities have great potential for a wide range of clinical applications as targeting agents for in vitro and in vivo immunodiagnosis, therapy and for improving immunoassays. They have shown great promise for targeting cytotoxic effector cells, delivering radionuclides, toxins or cytotoxic drugs to specific targets, particularly tumour cells. The development of BsAb research goes through three main stages: chemical cross linking of murine-derived monoclonal antibody, hybrid hybridomas and engineered BsAb. This article is providing the potential applications of bispecific antibodies. [Vet World 2012; 5(12.000: 775-780

  13. Which amphetamine-type stimulants can be detected by oral fluid immunoassays?

    Science.gov (United States)

    Souza, Daniele Z; Boehl, Paula O; Comiran, Eloisa; Prusch, Débora S; Zancanaro, Ivomar; Fuentefria, Alexandre M; Pechansky, Flavio; Duarte, Paulina C A V; De Boni, Raquel B; Fröehlich, Pedro E; Limberger, Renata P

    2012-02-01

    The use of oral fluid for monitoring drug consumption on roads has many advantages over conventional biological fluids; therefore, several immunoassays have been developed for this purpose. In this work, the ability of 3 commercial immunoassays to detect amphetamine-type stimulants (ATSs) in oral fluid was assessed. In addition, it was reviewed the main controlled ATSs available worldwide, as well as the oral fluid immunological screening tests that have been used for identifying ATSs in drivers. The analytical specificity of amphetamine direct enzyme-linked immunosorbent assay (ELISA), methamphetamine direct ELISA (Immunalysis Corporation), and Oral-View saliva multidrug of abuse test (Alfa Scientific Designs) was evaluated using ATS-spiked oral fluid. Legislation and published articles that report the use of immunological screening tests to detect ATS consumption in conductors were reviewed, including the kit's technical information, project reports, police and drug databases. Even at high concentrations, the tested assays were not able to detect methylphenidate, fenproporex, or diethylpropion, controlled ATSs legally marketed in many countries. This evidences the need to develop new kits that enable one to control the misuse of prescription ATSs on roads through oral fluid immunoassays.

  14. The Significance of Isolated Reactive Treponemal Enzyme Immunoassay in the Diagnosis of Early Syphilis.

    Science.gov (United States)

    Caswell, Rachel J; Hathorn, Emma; Manavi, Kaveh

    2016-06-01

    The Treponemal test algorithm for syphilis screening is widely used. A diagnostic challenge between identifying early syphilis versus a false positive signal occurs in cases where the treponemal enzyme immunoassay (EIA) is reactive and confirmatory T. pallidum particle agglutination assay is negative. We investigated the diagnostic outcome of isolated reactive EIA in patients attending a sexual health clinic. Results of syphilis serology tests carried out at Birmingham Whittall Street Clinic between August 10, 2010, and November 31, 2014, were reviewed. Cases with isolated EIA were routinely invited for repeat syphilis serology. Outcomes of patients with isolated EIA were reviewed and the proportion with confirmed positive syphilis serology on their repeat test identified. The number of isolated EIA cases needed to retest to identify 1 case of early syphilis was calculated. A total of 121,724 syphilis screening tests were performed. Among the 1561 individual patients with reactive EIA sera, 316 (20% of total reactive tests) had isolated reactive EIA. Repeat syphilis serology results of 163 patients were reviewed; 106 patients remained with isolated reactive EIA, 50 had negative EIA test and 7 (4.3%) had confirmed reactive EIA. Of the 7 patients, 2 had evidence of early syphilis infection. The number of isolated EIA needed to retest to identify 1 case of early syphilis was 81.5 (95% confidence interval, 22.9-671.4). Routine recall of patients with isolated EIA sera is not warranted. Risk of acquisition or presence of early syphilis should be assessed independently and irrespective of a negative syphilis screening test or isolated EIA.

  15. Enzyme-labeled Antigen Method: Development and Application of the Novel Approach for Identifying Plasma Cells Locally Producing Disease-specific Antibodies in Inflammatory Lesions

    International Nuclear Information System (INIS)

    Mizutani, Yasuyoshi; Shiogama, Kazuya; Onouchi, Takanori; Sakurai, Kouhei; Inada, Ken-ichi; Tsutsumi, Yutaka

    2016-01-01

    In chronic inflammatory lesions of autoimmune and infectious diseases, plasma cells are frequently observed. Antigens recognized by antibodies produced by the plasma cells mostly remain unclear. A new technique identifying these corresponding antigens may give us a breakthrough for understanding the disease from a pathophysiological viewpoint, simply because the immunocytes are seen within the lesion. We have developed an enzyme-labeled antigen method for microscopic identification of the antigen recognized by specific antibodies locally produced in plasma cells in inflammatory lesions. Firstly, target biotinylated antigens were constructed by the wheat germ cell-free protein synthesis system or through chemical biotinylation. Next, proteins reactive to antibodies in tissue extracts were screened and antibody titers were evaluated by the AlphaScreen method. Finally, with the enzyme-labeled antigen method using the biotinylated antigens as probes, plasma cells producing specific antibodies were microscopically localized in fixed frozen sections. Our novel approach visualized tissue plasma cells that produced 1) autoantibodies in rheumatoid arthritis, 2) antibodies against major antigens of Porphyromonas gingivalis in periodontitis or radicular cyst, and 3) antibodies against a carbohydrate antigen, Strep A, of Streptococcus pyogenes in recurrent tonsillitis. Evaluation of local specific antibody responses expectedly contributes to clarifying previously unknown processes in inflammatory disorders

  16. Immunoassay of paralytic shellfish toxins by moving magnetic particles in a stationary liquid-phase lab-on-a-chip.

    Science.gov (United States)

    Kim, Myoung-Ho; Choi, Suk-Jung

    2015-04-15

    In this study, we devised a stationary liquid-phase lab-on-a-chip (SLP LOC), which was operated by moving solid-phase magnetic particles in the stationary liquid phase. The SLP LOC consisted of a sample chamber to which a sample and reactants were added, a detection chamber containing enzyme substrate solution, and a narrow channel connecting the two chambers and filled with buffer. As a model system, competitive immunoassays of saxitoxin (STX), a paralytic shellfish toxin, were conducted in the SLP LOC using protein G-coupled magnetic particles (G-MPs) as the solid phase. Anti-STX antibodies, STX-horseradish peroxidase conjugate, G-MPs, and a STX sample were added to the sample chamber and reacted by shaking. While liquids were in the stationary state, G-MPs were transported from the sample chamber to the detection chamber by moving a magnet below the LOC. After incubation to allow the enzymatic reaction to occur, the absorbance of the detection chamber solution was found to be reciprocally related to the STX concentration of the sample. Thus, the SLP LOC may represent a novel, simple format for point-of-care testing applications of enzyme-linked immunosorbent assays by eliminating complicated liquid handling steps. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    OpenAIRE

    Alderete, J F

    1984-01-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses durin...

  18. Development of monoclonal-antibody-based products for medical research and diagnostic imaging. Technical report, 28 January 1987-31 December 1988 (Final)

    International Nuclear Information System (INIS)

    Rhodes, B.A.; Pant, K.D.; Chauhan, N.; Buckelew, J.; Budd, P.

    1989-04-01

    Two major areas of application of monoclonal antibodies were examined: the development of products to support the 'Antibody Delivery System', a parent-specific and variable antibody formula drug system for use in imaging and treatment of cancer, and the development of an antibody-based radiopharmaceutical for imaging occult abscesses and other conditions involving high concentrations of white blood cells. In development of the Antibody Delivery System components, methods for characterization and purification of monoclonal antibodies were developed and validated; a dot immunoassay test, under the name RhoDot (TM) Immunoassay, was developed for matching antibodies to putative tumor specimen: a radioimmunoassay, under the name PhoChek (TM) Quality Control Test Kit for Radiolabeled Antibodies, was developed and commercialized for measuring the immunoreactive fraction of radiolabeled antibodies specific to colorecal cancer; and a patient-specific quality control test was developed. In development of the antibody-based radiopharmaceutical for imaging occult abscesses, a candidate antibody was identified and produced under U.S. Food and Drug Administration standards preparatory to human clinical trials

  19. Targeted selected reaction monitoring mass spectrometric immunoassay for insulin-like growth factor 1.

    Directory of Open Access Journals (Sweden)

    Eric E Niederkofler

    Full Text Available Insulin-like growth factor 1 (IGF1 is an important biomarker of human growth disorders that is routinely analyzed in clinical laboratories. Mass spectrometry-based workflows offer a viable alternative to standard IGF1 immunoassays, which utilize various pre-analytical preparation strategies. In this work we developed an assay that incorporates a novel sample preparation method for dissociating IGF1 from its binding proteins. The workflow also includes an immunoaffinity step using antibody-derivatized pipette tips, followed by elution, trypsin digestion, and LC-MS/MS separation and detection of the signature peptides in a selected reaction monitoring (SRM mode. The resulting quantitative mass spectrometric immunoassay (MSIA exhibited good linearity in the range of 1 to 1,500 ng/mL IGF1, intra- and inter-assay precision with CVs of less than 10%, and lowest limits of detection of 1 ng/mL. The linearity and recovery characteristics of the assay were also established, and the new method compared to a commercially available immunoassay using a large cohort of human serum samples. The IGF1 SRM MSIA is well suited for use in clinical laboratories.

  20. Comparison of different assays to assess human papillomavirus (HPV) type 16- and 18-specific antibodies after HPV infection and vaccination

    NARCIS (Netherlands)

    Scherpenisse, Mirte; Schepp, Rutger M.; Mollers, Madelief; Mooij, Sofie H.; Meijer, Chris J. L. M.; Berbers, Guy A. M.; van der Klis, Fiona R. M.

    2013-01-01

    We compared the measurement of human papillomavirus (HPV)-specific serum antibody levels with the virus-like-particle multiplex immunoassay (VLP-MIA), competitive Luminex immunoassay (cLIA), and glutathione S-transferase (GST) L1-based MIA. Using a large panel of serum samples, these assays showed

  1. Hyperthyroidism in Patients with Graves' Ophthalmopathy, and Thyroidal, Skeletal and Eye Muscle Specific Type 2 Deiodinase Enzyme Activities.

    Science.gov (United States)

    Molnár, Ildikó; Szentmiklósi, József A; Somogyiné-Vári, Éva

    2017-09-01

    Graves' ophthalmopathy is characterized by hyperthyroidism, which is associated with higher serum T 3 levels than T 4 due to deiodinase enzymes.The effect of Graves' patient's sera (n=52) with elevated thyroid hormone and TSH receptor or thyroid peroxidase antibody (anti-TPO) levels was investigated on thyroidal, skeletal and eye muscle type 2 deiodinase enzyme (DII) activities. DII activities were measured with 125 I-T 4 substrate, while thyroid hormone and antibody levels with immunoassays.In Graves' ophthalmopathy, sera with elevated FT 4 or FT 3 levels reduced DII activites remarkably in all tissue fractions. Thyroidal DII activities were lower than those using eye muscle fraction (0.6±0.22 vs 1.14±0.43 pmol/mg/min, PEffect of sera with increased FT 3 levels demonstrated also reduced DII activities in patients with Graves' ophthalmopathy after methimazole therapy compared to those who had no ophthalmopathy (2.88±2 vs 20.42±11.82 pmol/mg/min, PHyperthyroid sera with TSH receptor antibodies resulted in increased DII activities, while sera with anti-TPO antibodies were connected to lower DII activities in Graves' ophthalmopathy.In summary, the actions of hyperthyroid sera derived from patients with Graves' disease were tested on tissue-specific DII activities. Elevated FT 4 level-induced DII inactivation is present in Graves' ophthalmopathy, which seems to be also present at the beginning of methimazole therapy. Stimulating TSH receptor antibiodies increased DII activities via their nongenomic effects using sera of hyperthyroid Graves' ophthalmopathy, but anti-TPO antibodies could influence DII activities via altering FT 4 levels. © Georg Thieme Verlag KG Stuttgart · New York.

  2. DOSAGEM DE METABÓLITOS DE GLUCOCORTICOIDES E PROGESTERONA EM FEZES DE PAPAGAIO-VERDADEIRO (AMAZONA AESTIVA

    Directory of Open Access Journals (Sweden)

    Caroline Junko Fujihara

    2014-09-01

    Full Text Available The objectives of the present study were to evaluate fecal concentrations of metabolites of glucocorticoids, measured by enzyme immunoassay with a cortisol antibody and by radioimmunoassay with a corticosterone antibody, and progesterone by radioimmunoassay with a progesterone antibody in blue-fronted parrot (Amazona aestiva after ACTH challenge. The adrenal stimulation with ACTH (25 UI/animal resulted in an increase of fecal glucocorticoids metabolites concentration, but it did not affect the concentrations of fecal progesterone metabolites. Although there were no synchronized peaks of glucocorticoid metabolites excretion measured by enzyme immunoassay and radioimmunoassay, there were two peaks of excretion, one at 2-4 hours and other at 8-10 hours. Despite the occurrence of peaks, the analysis of fecal glucocorticoids metabolites and progesterone metabolites showed no effect of group (control and treatment, moment (hours of sampling and sex.

  3. Antiphospholipid antibodies detected by line immunoassay differentiate among patients with antiphospholipid syndrome, with infections and asymptomatic carriers.

    Science.gov (United States)

    Roggenbuck, Dirk; Borghi, Maria Orietta; Somma, Valentina; Büttner, Thomas; Schierack, Peter; Hanack, Katja; Grossi, Claudia; Bodio, Caterina; Macor, Paolo; von Landenberg, Philipp; Boccellato, Francesco; Mahler, Michael; Meroni, Pier Luigi

    2016-05-21

    Antiphospholipid antibodies (aPL) can be detected in asymptomatic carriers and infectious patients. The aim was to investigate whether a novel line immunoassay (LIA) differentiates between antiphospholipid syndrome (APS) and asymptomatic aPL+ carriers or patients with infectious diseases (infectious diseases controls (IDC)). Sixty-one patients with APS (56 primary, 22/56 with obstetric events only, and 5 secondary), 146 controls including 24 aPL+ asymptomatic carriers and 73 IDC were tested on a novel hydrophobic solid phase coated with cardiolipin (CL), phosphatic acid, phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, phosphatidylinositol, phosphatidylserine, beta2-glycoprotein I (β2GPI), prothrombin, and annexin V. Samples were also tested by anti-CL and anti-β2GPI ELISAs and for lupus anticoagulant activity. Human monoclonal antibodies (humoAbs) against human β2GPI or PL alone were tested on the same LIA substrates in the absence or presence of human serum, purified human β2GPI or after CL-micelle absorption. Comparison of LIA with the aPL-classification assays revealed good agreement for IgG/IgM aß2GPI and aCL. Anti-CL and anti-ß2GPI IgG/IgM reactivity assessed by LIA was significantly higher in patients with APS versus healthy controls and IDCs, as detected by ELISA. IgG binding to CL and ß2GPI in the LIA was significantly lower in aPL+ carriers and Venereal Disease Research Laboratory test (VDRL) + samples than in patients with APS. HumoAb against domain 1 recognized β2GPI bound to the LIA-matrix and in anionic phospholipid (PL) complexes. Absorption with CL micelles abolished the reactivity of a PL-specific humoAb but did not affect the binding of anti-β2GPI humoAbs. The LIA and ELISA have good agreement in detecting aPL in APS, but the LIA differentiates patients with APS from infectious patients and asymptomatic carriers, likely through the exposure of domain 1.

  4. Novel immunoassay formats for integrated microfluidic circuits: diffusion immunoassays (DIA)

    Science.gov (United States)

    Weigl, Bernhard H.; Hatch, Anson; Kamholz, Andrew E.; Yager, Paul

    2000-03-01

    Novel designs of integrated fluidic microchips allow separations, chemical reactions, and calibration-free analytical measurements to be performed directly in very small quantities of complex samples such as whole blood and contaminated environmental samples. This technology lends itself to applications such as clinical diagnostics, including tumor marker screening, and environmental sensing in remote locations. Lab-on-a-Chip based systems offer many *advantages over traditional analytical devices: They consume extremely low volumes of both samples and reagents. Each chip is inexpensive and small. The sampling-to-result time is extremely short. They perform all analytical functions, including sampling, sample pretreatment, separation, dilution, and mixing steps, chemical reactions, and detection in an integrated microfluidic circuit. Lab-on-a-Chip systems enable the design of small, portable, rugged, low-cost, easy to use, yet extremely versatile and capable diagnostic instruments. In addition, fluids flowing in microchannels exhibit unique characteristics ('microfluidics'), which allow the design of analytical devices and assay formats that would not function on a macroscale. Existing Lab-on-a-chip technologies work very well for highly predictable and homogeneous samples common in genetic testing and drug discovery processes. One of the biggest challenges for current Labs-on-a-chip, however, is to perform analysis in the presence of the complexity and heterogeneity of actual samples such as whole blood or contaminated environmental samples. Micronics has developed a variety of Lab-on-a-Chip assays that can overcome those shortcomings. We will now present various types of novel Lab- on-a-Chip-based immunoassays, including the so-called Diffusion Immunoassays (DIA) that are based on the competitive laminar diffusion of analyte molecules and tracer molecules into a region of the chip containing antibodies that target the analyte molecules. Advantages of this

  5. Evaluation of enzyme immunoassay techniques for diagnosis of the most common intestinal protozoa in fecal samples.

    Science.gov (United States)

    Gaafar, Maha R

    2011-08-01

    This study was designed to evaluate the antigen capture enzyme immunoassays (EIAs) Triage parasite panel and TechLab Entamoeba histolytica II in detecting Giardia intestinalis, Cryptosporidium sp, and Entamoeba histolytica in fecal samples in comparison to microscopy, and in differentiating Entamoeba histolytica from Entamoeba dispar. The Triage EIA was evaluated using 100 stool specimens that were tested by standard ova and parasite examination, including staining with both trichrome and modified acid-fast stains. Differentiation between E. histolytica and E. dispar was performed using TechLab. Microscopic examination revealed that 19% of the samples were positive for Giardia, 4% for Cryptosporidium, and 1% for E. histolytica/E. dispar, and other parasites were found in 5%. By Triage, 23% of the samples were infected with Giardia, 5% with Cryptosporidium, and 2% with E. histolytica/E. dispar. Triage showed a sensitivity of 100% and specificity of 91.5%. The TechLab assay was negative for both samples diagnosed as E. histolytica/E. dispar by Triage, which suggested that they were E. dispar. Both tests showed no cross-reactivity with other intestinal protozoa. These results indicate that antigen detection by EIA has the potential to become a valuable tool, capable of making stool diagnostics more effective. Copyright © 2011 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  6. Development of a single-chain variable fragment-alkaline phosphatase fusion protein and a sensitive direct competitive chemiluminescent enzyme immunoassay for detection of ractopamine in pork

    Energy Technology Data Exchange (ETDEWEB)

    Dong Jiexian; Li Zhenfeng; Lei Hongtao; Sun Yuanming [Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642 (China); Ducancel, Frederic [CEA, iBiTec-S, Service de Pharmacologie et d' Immnoanalyse (SPI), CEA Saclay, F-91191 Gif sur Yvette (France); Xu Zhenlin [Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642 (China); Boulain, Jean-Claude [CEA, iBiTec-S, Service de Pharmacologie et d' Immnoanalyse (SPI), CEA Saclay, F-91191 Gif sur Yvette (France); Yang Jinyi; Shen Yudong [Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642 (China); Wang Hong, E-mail: gzwhongd@63.com [Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642 (China)

    2012-07-29

    Graphical abstract: Detection model of dc-CLEIA based on anti-RAC scFv-AP fusion protein. Highlights: Black-Right-Pointing-Pointer The scFv-AP fusion protein against ractopamine (RAC) was produced. Black-Right-Pointing-Pointer A dc-CLEIA for RAC was developed based on the purified scFv-AP fusion protein. Black-Right-Pointing-Pointer The sensitivity of dc-CLEIA was 10 times as sensitive as dc-ELISA for RAC. Black-Right-Pointing-Pointer Recovery tests from pork samples were studied. Black-Right-Pointing-Pointer Good accuracy was obtained. - Abstract: A rapid, sensitive chemiluminescent enzyme immunoassay (CLEIA) for ractopamine (RAC) based on a single-chain variable fragment (scFv)-alkaline phosphatase (AP) fusion protein was developed. The scFv gene was prepared by cloning the heavy- and light-chain variable region genes (V{sub H} and V{sub L}) from hybridoma cell line AC2, which secretes antibodies against RAC, and assembling V{sub H} and V{sub L} genes with a linker by means of splicing overlap extension polymerase chain reaction. The resulting scFv gene was inserted into the expression vector pLIP6/GN containing AP to produce the fusion protein in Escherichia coli strain BL21. The purified scFv-AP fusion protein was used to develop a direct competitive CLEIA (dcCLEIA) protocol for detection of RAC. The average concentration required for 50% inhibition of binding and the limit of detection of the assay were 0.25 {+-} 0.03 and 0.02 {+-} 0.004 ng mL{sup -1}, respectively, and the linear response range extended from 0.05 to 1.45 ng mL{sup -1}. The assay was 10 times as sensitive as the corresponding enzyme-linked immunosorbent assay based on the same fusion protein. Cross-reactivity studies showed that the fusion protein did not cross react with RAC analogs. DcCLEIA was used to analyze RAC spiked pork samples, and the validation was confirmed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS). The results showed a good correlation between

  7. Detection of Antibody to Envelope (E2 Antigen of Hepatitis C Virus

    Directory of Open Access Journals (Sweden)

    RK Chaudhary

    1997-01-01

    Full Text Available One hundred and four clinical specimens from provincial public health laboratories were tested for antibody to hepatitis C virus (HCV envelope protein (anti-E2. To evaluate the effect of hypervariability of E2 region on anti-E2 assay, 49 recombinant immunoblot assay (RIBA 3.0 positive samples were genotyped. All 49 genotyped samples were positive for anti-E2. Eight of 12 (67% indeterminate, HCV RNA positive samples were anti-E2 reactive. Nine of 30 (30% indeterminate, HCV RNA negative samples were also positive for anti-E2. Anti-E2 was detected in two of 13 (15% RIBA-negative and enzyme immunoassays-positive samples. Although small number of samples were tested, the results showed that it may be possible to resolve indeterminate samples with the anti-E2 assay.

  8. Stratification of antibody-positive subjects by antibody level reveals an impact of immunogenicity on pharmacokinetics.

    Science.gov (United States)

    Zhou, Lei; Hoofring, Sarah A; Wu, Yu; Vu, Thuy; Ma, Peiming; Swanson, Steven J; Chirmule, Narendra; Starcevic, Marta

    2013-01-01

    The availability of highly sensitive immunoassays enables the detection of antidrug antibody (ADA) responses of various concentrations and affinities. The analysis of the impact of antibody status on drug pharmacokinetics (PK) is confounded by the presence of low-affinity or low-concentration antibody responses within the dataset. In a phase 2 clinical trial, a large proportion of subjects (45%) developed ADA following weekly dosing with AMG 317, a fully human monoclonal antibody therapeutic. The antibody responses displayed a wide range of relative concentrations (30 ng/mL to >13 μg/mL) and peaked at various times during the study. To evaluate the impact of immunogenicity on PK, AMG 317 concentration data were analyzed following stratification by dose group, time point, antibody status (positive or negative), and antibody level (relative concentration). With dose group as a stratifying variable, a moderate reduction in AMG 317 levels (AMG 317 levels was revealed when antibody data was stratified by both time point and antibody level. In general, high ADA concentrations (>500 ng/mL) and later time points (week 12) were associated with significantly (up to 97%) lower trough AMG 317 concentrations. The use of quasi-quantitative antibody data and appropriate statistical methods was critical for the most comprehensive evaluation of the impact of immunogenicity on PK.

  9. Characterization of thyroid function and antithyroid antibody tests among Saudis

    Science.gov (United States)

    Jammah, Anwar A.; Alshehri, Anwar S.; Alrakhis, Afaf A.; Alhedaithy, Asma S.; Almadhi, Asma M.; Alkwai, Hala M.; Alhamad, Maram M.; Alzahrani, Saad H.

    2015-01-01

    Objective: To determine the reference intervals for thyroid function tests and the prevalence of thyroid autoimmunity in the Saudi population. Methods: A cross-sectional prospective study was conducted in King Khalid University Hospital, Riyadh, Saudi Arabia from January to June 2013. History and physical examination were obtained. Thyroid-stimulating hormone (TSH), free thyroxine (FT4), and free triiodothyronine (FT3) were measured by Electro-chemiluminescence Immunoassay system-assay. Anti-thyroperoxidase, and anti-thyroglobulin antibodies were measured using enzyme-linked immunosorbent-assay. Subjects with previous or a family history of thyroid disorders, those taking medications affecting thyroid function, pregnant or lactating women, and those with goiter were excluded. Individuals with positive antibodies were excluded from the final analysis of the TSH reference range, but were used to determine the prevalence of thyroid autoimmunity. Results: Out of 337 Saudi subjects initially screened, 132 (aged 13-60 years) were candidates for reference calculation, the mean±standard deviation, and (2.5th-97.5th) percentile of TSH (mIU/L) was 1.96±0.9 (0.59-4.37), for FT4 (pmol/L) was 15.47±1.83 (12.04-19.13), and for FT3 (pmol/L) was 5.22±0.7 (4.07-6.76). The TSH was higher in the antibodies positive group (2.5±1.17 mIU/L) compared with the negative one (1.96±0.9 mIU/L) (pantithyroid antibodies. Conclusion: The TSH reference range was similar to laboratory references. Thyroid antibodies were prevalent in Saudis, necessitating further work in larger scale studies. PMID:25987111

  10. Detection by radioimmunoassay and enzyme-linked immunosorbent assay of coronavirus antibodies in bovine serum and lacteal secretions.

    Science.gov (United States)

    Rodak, L; Babiuk, L A; Acres, S D

    1982-07-01

    The sensitivity of a radioimmunoassay (RIA), an enzyme-linked immunosorbent assay (ELISA), and a serum neutralization assay (SN) for detecting antibodies to bovine coronavirus in serum and colostrum were compared. Although there proved to be a good correlation among all three assays (r = 0.915 and 0.964 for RIA with SN and ELISA, respectively), RIA and ELISA proved to be at least 10 times more sensitive than neutralization tests. By using these techniques, it was possible to detect a time-dependent decrease in antibody levels in bovine colostrum after parturition. Using ELISA, we demonstrated that 12 of 12 herds in Saskatchewan, and 109 of 110 animals tested, and antibody to bovine coronavirus. There was no elevated antibody response in serum or lacteal secretions of cows vaccinated once or twice with a commercially available modified live rota-coronavirus vaccine. In addition to being more sensitive than SN, ELISA and RIA proved to have other advantages for measuring antibody levels to bovine coronavirus and therefore warrant wider use as tools in diagnostic virology.

  11. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  12. Polyclonal antibody to ovomucoid determination in gamma irradiated laying eggs

    International Nuclear Information System (INIS)

    Harder, Marcia N.C.; Arthur, Valter; Silva, Lucia C.A.S.; Lopes, Tatiana G.G.; Duarte, Keila M.R.; Canniatti-Brazaca, Solange G.; Savino, Vicente J.M.; Coelho, Antonio A.D.

    2009-01-01

    To determine allergenic food proteins, one of the most used tests is the immunoassays such as ELISA (enzyme linked immunosorbent assay), where the antibody recognizes the antigen and this connection is showed by an enzymatic system, in other words, optical density. The aim of this study was to determine the polyclonal antibody efficiency, produced in laboratory, to identify the presence the ovomucoid antigen in treated eggs by gamma irradiation for its inactivation. To evaluate the treatments, polyclonal antibody was produced in female rabbits immunized with bioconjugated ovomucoid. Was used Freund Complete Adjuvant at first immunization and PBS Buffer at four subsequently immunizations every fifteen days, plus a booster 48 hours before the blood retreated. The blood serum was tittered by PTA-ELISA (Plate trapped antigen). All procedures were according to European Norms for ethical and animal welfare. It was used, in nature, commercial laying eggs. So the samples were submitted to the gamma radiation coming from a source of Co 60 , type Multipurpose, under a dose rate of 19.4 and 31.8 Gy/hour, in the doses: 0 (control); 10 KGy; 20 KGy and 30 KGy, in all rates. By the ELISA.s test we can find the egg allergen ovomucoid and the radiation treatment do not showed considerable changes. So we can concluded that the antibody produced is capable of identify the ovomucoid allergenic protein and the gamma irradiation in such rates does not shows changes in that protein, therefore showed some changes in the color and visual viscosity of the egg samples. (author)

  13. Polyclonal antibody to ovomucoid determination in gamma irradiated laying eggs

    Energy Technology Data Exchange (ETDEWEB)

    Harder, Marcia N.C.; Arthur, Valter; Silva, Lucia C.A.S.; Lopes, Tatiana G.G. [Centro de Energia Nuclear na Agricultura (CENA/USP, Piracicaba, SP. Dept. de Radiobiologia e Ambiente) (Brazil)], e-mail: mnharder@cena.usp.br, e-mail: arthur@cena.usp.br, e-mail: tgglopes@cena.usp.br; Duarte, Keila M.R. [Instituto de Zootecnia (IZ . Nova Odessa), Nova Odessa, SP (Brazil)], e-mail: keila@iz.sp.gov.br; Canniatti-Brazaca, Solange G.; Savino, Vicente J.M.; Coelho, Antonio A.D. [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil)], e-mail: sgcbraza@esalq.usp.br, e-mail: vjmsavin@esalq.usp.br, e-mail: aadcoelh@esalq.usp.br

    2009-07-01

    To determine allergenic food proteins, one of the most used tests is the immunoassays such as ELISA (enzyme linked immunosorbent assay), where the antibody recognizes the antigen and this connection is showed by an enzymatic system, in other words, optical density. The aim of this study was to determine the polyclonal antibody efficiency, produced in laboratory, to identify the presence the ovomucoid antigen in treated eggs by gamma irradiation for its inactivation. To evaluate the treatments, polyclonal antibody was produced in female rabbits immunized with bioconjugated ovomucoid. Was used Freund Complete Adjuvant at first immunization and PBS Buffer at four subsequently immunizations every fifteen days, plus a booster 48 hours before the blood retreated. The blood serum was tittered by PTA-ELISA (Plate trapped antigen). All procedures were according to European Norms for ethical and animal welfare. It was used, in nature, commercial laying eggs. So the samples were submitted to the gamma radiation coming from a source of Co{sup 60}, type Multipurpose, under a dose rate of 19.4 and 31.8 Gy/hour, in the doses: 0 (control); 10 KGy; 20 KGy and 30 KGy, in all rates. By the ELISA.s test we can find the egg allergen ovomucoid and the radiation treatment do not showed considerable changes. So we can concluded that the antibody produced is capable of identify the ovomucoid allergenic protein and the gamma irradiation in such rates does not shows changes in that protein, therefore showed some changes in the color and visual viscosity of the egg samples. (author)

  14. Detection of antibodies to the extractable nuclear antigens by enzyme linked immunosorbent assay

    International Nuclear Information System (INIS)

    Aziz, Khalil A.; Fzizal, Abul A.

    2005-01-01

    Anti-extractable nuclear antigen (ENA) antibodies are a group of autoantibodies that are directed against various components of the cell nucleus. Antibodies to these antigens are closely associated with connective tissue disease. Early diagnosis of these diseases can prove very difficult and therefore clinicians rely on the use of anti-ENA antibody testing for the exclusion. Old methods of testing are time consuming and require great skills. For these reasons clinical immunology laboratories are switching to testing for anti-ENA antibodies by enzyme linked immunosorbent assay (ELISA). The latter assays are more sensitive and require little skills. In the present study we have investigated a number of different ELISA preparations. The study was conducted at Birmingham Heartlands Hospital during the period 2003. We tested a number of ENA-positive and negative samples using 3 different commercial ELISA preparations and compared the results with traditional CCIE-assay. The present study revealed that some ELISA preparations can be more sensitive than CCIE method. Laboratories still using later method should switch to ELISA. However it is important that laboratories evaluate a long range of different ELISA preparations before selecting the most optimal one. In addition it is recommended that laboratories then audit results in order to determine true significance of such results. Finally until the true significance of ELISA generated results is known, positive ENA-results should be interpreted in conjunction with the clinical picture and this would require close liaison in between the clinical immunology laboratory and clinicians

  15. Influenza A plasma and serum virus antibody detection comparison in dogs using blocking enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    H. T. Lin

    2015-05-01

    Full Text Available Background and Aim: The influenza A virus (IAV is an important zoonotic pathogen with infections also reported in dogs. IAV infections can be detected through the presence of antibodies using the enzyme-linked immunosorbent assay (ELISA. Serum is the only standard sample source; however, there is no information on the availability of other sample sources for IAV antibody detection in dogs. Compared with serum, plasma is more widely employed in most animal hospitals. The object of this study is to investigate whether plasma collected in ethylenediaminetetraacetic acid (EDTA tubes (EDTA plasma or heparin tubes (heparin plasma could be used in the ELISA protocol instead of serum for IAV antibody detection in dogs. Materials and Methods: Totally, 82 matched EDTA plasma and serum sample pairs and 79 matched heparin plasma and serum sample pairs were employed using blocking enzyme-linked immunosorbent assay (bELISA. The agreement and correlation between the plasma (EDTA or heparin plasma and serum were assessed using the agreement index kappa (kD calculation and Pearson correlation coefficient, respectively. Results: The agreement index kD of EDTA plasma and serum was 1.0, and that of heparin plasma and serum was 0.85. The Pearson correlation coefficient of EDTA plasma and serum was 0.87 (p<0.01, and that of heparin plasma and serum was 0.82 (p<0.01. Conclusion: The results proved that plasma, especially EDTA plasma, could be substituted for serum in the bELISA test. This might greatly expand the clinical applicability of IAV antibody detection in dogs.

  16. A polyclonal antibody based immunoassay detects seven subtypes of Shiga toxin 2 produced by Escherichia coli in human and environmental samples.

    Directory of Open Access Journals (Sweden)

    Xiaohua He

    Full Text Available BACKGROUND: Shiga toxin-producing Escherichia coli (STEC are frequent causes of severe human diseases ranging from diarrhea to hemolytic uremic syndrome. The existing strategy for detection of STEC relies on the unique sorbitol-negative fermentation property of the O157 strains, the most commonly identified serotype has been E. coli O157. It is becoming increasingly evident, however, that numerous non-O157 STEC serotypes also cause outbreaks and severe illnesses. It is necessary to have new methods that are capable of detecting all STEC strains. METHODS AND FINDINGS: Here we describe the development of a sandwich ELISA assay for detecting both O157 and non-O157 STECs by incorporating a novel polyclonal antibody (pAb against Stx2. The newly established immunoassay was capable of detecting Stx2a spiked in environmental samples with a limit of detection between 10 and 100 pg/mL in soil and between 100 and 500 pg/mL in feces. When applied to 36 bacterial strains isolated from human and environmental samples, this assay detected Stx2 in all strains that were confirmed to be stx2-positive by real-time PCR, demonstrating a 100% sensitivity and specificity. CONCLUSIONS: The sandwich ELISA developed in this study will enable any competent laboratory to identify and characterize Stx2-producing O157 and non-O157 strains in human and environmental samples, resulting in rapid diagnosis and patient care. The results of epitope mapping from this study will be useful for further development of a peptide-based antibody and vaccine.

  17. Chemiluminescence immunoassay based on dual signal amplification strategy of Au/mesoporous silica and multienzyme functionalized mesoporous silica

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jiehua, E-mail: linjiehua@qust.edu.cn [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China); Zhao Yue; Wei Zhijing; Wang Wei [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China)

    2011-11-15

    Highlights: > The increased amount of monoclonal antibody in Au/SiO{sub 2} led to a wider linear range. > Due to the increased HRP tags in HRP-Ab{sub 2}/SiO{sub 2}, signal amplification achieved. > A simple dual amplification immunoassay achieved with flow injection analysis. - Abstract: A chemiluminescent dual signal amplification strategy for the determination of {alpha}-fetoprotein (AFP) was proposed based on a sandwich immunoassay format. Monoclonal antibody of AFP immobilized on the gold nanoparticles doped mesoporous SiO{sub 2} (Au/SiO{sub 2}) were prepared and used as a primary antibody. Horseradish peroxidase (HRP) and HRP-labeled secondary antibody (Ab{sub 2}) co-immobilized into the mesoporous SiO{sub 2} nanoparticles (HRP-Ab{sub 2}/SiO{sub 2}) were used as the labeled immunological probe. Due to the high ratio surface areas and pore volumes of the mesoporous SiO{sub 2}, not only the amount of AFP monoclonal antibody but also the amount of the modified HRP and Ab{sub 2} in HRP-Ab{sub 2}/SiO{sub 2} were largely increased. Thus the chemiluminescent signal was amplified by using the system of luminol and H{sub 2}O{sub 2} under the catalysis of HRP. Under the optimal conditions, two linear ranges for AFP were obtained from 0.01 to 0.5 ng mL{sup -1} and 0.5 to 100 ng mL{sup -1} with a detection limit of 0.005 ng mL{sup -1} (3{sigma}). The fabricated signal amplification strategy showed an excellent promise for sensitive detection of AFP and other tumor markers.

  18. Determination of Aspergillus pathogens in agricultural products by a specific nanobody-polyclonal antibody sandwich ELISA.

    Science.gov (United States)

    Wang, Ting; Li, Peiwu; Zhang, Qi; Zhang, Wen; Zhang, Zhaowei; Wang, Tong; He, Ting

    2017-06-28

    Aspergillus and its poisonous mycotoxins are distributed worldwide throughout the environment and are of particular interest in agriculture and food safety. In order to develop a specific method for rapid detection of Aspergillus flavus to forecast diseases and control aflatoxins, a nanobody, PO8-VHH, highly reactive to A. flavus was isolated from an immunized alpaca nanobody library by phage display. The nanobody was verified to bind to the components of extracellular and intracellular antigen from both A. flavus and A. parasiticus. To construct a sandwich format immunoassay, polyclonal antibodies against Aspergillus were raised with rabbits. Finally, a highly selective nanobody-polyclonal antibody sandwich enzyme-linked immunosorbent assay was optimized and developed. The results revealed that the detection limits of the two fungi were as low as 1 μg mL -1 , and that it is able to detect fungal concentrations below to 2 μg mg -1 of peanut and maize grains in both artificially and naturally contaminated samples. Therefore, we here provided a rapid and simple method for monitoring Aspergillus spp. contamination in agricultural products.

  19. Modification of a deoxynivalenol-antigen-mimicking nanobody to improve immunoassay sensitivity by site-saturation mutagenesis.

    Science.gov (United States)

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Wang, Wei; Liu, Yuan-Yuan

    2016-01-01

    A nanobody (N-28) which can act as a deoxynivalenol (DON) antigen has been generated, and its residues Thr102-Ser106 were identified to bind with anti-DON monoclonal antibody by alanine-scanning mutagenesis. Site-saturation mutagenesis was used to analyze the plasticity of five residues and to improve the sensitivity of the N-28-based immunoassay. After mutagenesis, three mutants were selected by phage immunoassay and were sequenced. The half-maximal inhibitory concentrations of the immunoassay based on mutants N-28-T102Y, N-28-V103L, and N-28-Y105F were 24.49 ± 1.0, 51.83 ± 2.5, and 35.65 ± 1.6 ng/mL, respectively, showing the assay was, respectively, 3.2, 1.5, and 2.2 times more sensitive than the wild-type-based assay. The best mutant, N-28-T102Y, was used to develop a competitive phage ELISA to detect DON in cereals with high specificity and accuracy. In addition, the structural properties of N-28-T102Y and N-28 were investigated, revealing that the affinity of N-28-T102Y decreased because of increased steric hindrance with the large side chain. The lower-binding-affinity antigen mimetic may contribute to the improvement of the sensitivity of competitive immunoassays. These results demonstrate that nanobodies would be a favorable tool for engineering. Moreover, our results have laid a solid foundation for site-saturation mutagenesis of antigen-mimicking nanobodies to improve immunoassay sensitivity for small molecules.

  20. Sandwich enzyme-linked immunosorbent assay (ELISA) for measuring the concentration of, and detection of antibodies to, Aujeszky's disease virus.

    Science.gov (United States)

    Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z

    1990-01-01

    A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.

  1. Rapid bead-based immunoassay for measurement of mannose-binding lectin

    DEFF Research Database (Denmark)

    Bay, J T; Garred, P

    2009-01-01

    have been developed more automated platforms for MBL analysis is urgently needed. To pursue this, we set out to develop a flexible bead-based MBL immunoassay. Serum was obtained from 98 healthy individuals and 50 patients investigated for possible immunodeficiencies. We used the Luminex xMAP bead array...... coefficient were found be 7.88% and 5.70%, respectively. A close correlation between the new assay and a reference MBL measurement ELISA was found (rho 0.9381, P bead-based assay was less sensitive to interfering anti-murine antibodies in the blood samples than when the antibodies employed were...... used in the reference polystyrene-based ELISA. The new assay could be performed in 3 h with less than 25 microl serum required of each sample. These results show that MBL can be measured readily using a bead-based platform, which may form an efficient basis for a multiplex approach to measure different...

  2. A versatile SERS-based immunoassay for immunoglobulin detection using antigen-coated gold nanoparticles and malachite green-conjugated protein A/G

    Science.gov (United States)

    A surface enhanced Raman scattering (SERS) immunoassay for antibody detection in serum is described in the present work. The developed assay is conducted in solution and utilizes Au nanoparticles coated with the envelope (E) protein of West Nile Virus (WNV) as the SERS-active substrate and malachite...

  3. Application of solid-phase antibodies to radioimmunoassay

    International Nuclear Information System (INIS)

    McConway, M.G.; Chapman, R.S.

    1986-01-01

    Two types of polymeric microparticle, Dynospheres and reprecipitated acid-hydrolysed nylon 6/6, and two methods of activating these particles with either tresyl chloride or carbonyldiimidazole (CDI) prior to covalent linkage of antibodies were investigated with a view towards their respective adoption for the preparation of general solid-phase reagents for immunoassay applications. Activation of each particle and coupling of antibodies was rapid irrespective of the activator. CDI proved to be the activator of choice since it was cheap, less hazardous, more efficient and less pH dependent than tresyl chloride. Both types of microparticle remain buoyant during the RIA incubation periods and form stable pellets after centrifugation. In second antibody applications immobilisation of the first antibody occurs with a short incubation period of 30 min. Nylon microparticles have a higher antibody-coupling capacity and are the particles of choice in both first and second antibody applications. However, the nylon microparticles possess marginally higher non-specific binding characteristics. (Auth.)

  4. Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context

    OpenAIRE

    Tiwari, Aseem K.; Pandey, Prashant K.; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C.; Rawat, Ganesh

    2015-01-01

    Introduction: Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A...

  5. Improved quantification of a commercial enzyme-linked immunosorbent assay kit for measuring anti-MDA5 antibody.

    Science.gov (United States)

    Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka

    2018-04-09

    To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.

  6. Synthesis of hapten and preparation of specific polyclonal antibody with high affinity for lenalidomide, the potent drug for treatment of multiple myeloma

    Directory of Open Access Journals (Sweden)

    Darwish Ibrahim A

    2012-10-01

    Full Text Available Abstract Background For therapeutic monitoring and pharmacokinetic studies of lenalidomide (LND, the potent drug for treatment of multiple myeloma (MM, a specific antibody was required for the development of a sensitive immunoassay system for the accurate determination of LND in plasma. Results In this study, a hapten of LND (N-glutaryl-LND was synthesized by introducing the glutaryl moiety, as a spacer, into the primary aromatic amine site of the LND molecular structure. The structure of the hapten (G-LND was confirmed by mass, 1H-NMR, and 13C spectrometric techniques. G-LND was coupled to each of bovine serum albumin (BSA and keyhole limpet hemocyanin (KLH proteins by ethyl-3-(3-dimethylaminopropyl carbodiimide as a coupling reagent. LND-KLH conjugate was used as an immunogen. Four female 2-3 months old New Zealand white rabbits were immunized with an emulsion of LND-KLH with Freund`s adjuvant. The immune response of the rabbits was monitored by direct enzyme-linked immunosorbent assay (ELISA using LND-BSA immobilized onto microwell plates as a solid phase. The rabbit that showed the highest antibody titer and affinity to LND was scarified and its sera were collected. The IgG fraction was isolated and purified by affinity chromatography on protein A column. The specificity of the purified antibody for LND was evaluated by indirect competitive ELISA using dexamethasone as a competitor as it is used with LND in a combination therapy. Conclusions The high affinity of the antibody (IC50 = 10 ng/mL will be useful in the development of an immunoassay system for the determination of plasma LND concentrations. Current research is going to optimize the assay conditions and validate the procedures for the routine application in clinical laboratories.

  7. Synthesis of hapten and preparation of specific polyclonal antibody with high affinity for lenalidomide, the potent drug for treatment of multiple myeloma.

    Science.gov (United States)

    Darwish, Ibrahim A; Alzoman, Nourh Z; Abuhejail, Reem M; El-Samani, Tilal E

    2012-10-26

    For therapeutic monitoring and pharmacokinetic studies of lenalidomide (LND), the potent drug for treatment of multiple myeloma (MM), a specific antibody was required for the development of a sensitive immunoassay system for the accurate determination of LND in plasma. In this study, a hapten of LND (N-glutaryl-LND) was synthesized by introducing the glutaryl moiety, as a spacer, into the primary aromatic amine site of the LND molecular structure. The structure of the hapten (G-LND) was confirmed by mass, 1H-NMR, and 13C spectrometric techniques. G-LND was coupled to each of bovine serum albumin (BSA) and keyhole limpet hemocyanin (KLH) proteins by ethyl-3-(3-dimethylaminopropyl) carbodiimide as a coupling reagent. LND-KLH conjugate was used as an immunogen. Four female 2-3 months old New Zealand white rabbits were immunized with an emulsion of LND-KLH with Freund`s adjuvant. The immune response of the rabbits was monitored by direct enzyme-linked immunosorbent assay (ELISA) using LND-BSA immobilized onto microwell plates as a solid phase. The rabbit that showed the highest antibody titer and affinity to LND was scarified and its sera were collected. The IgG fraction was isolated and purified by affinity chromatography on protein A column. The specificity of the purified antibody for LND was evaluated by indirect competitive ELISA using dexamethasone as a competitor as it is used with LND in a combination therapy. The high affinity of the antibody (IC50 = 10 ng/mL) will be useful in the development of an immunoassay system for the determination of plasma LND concentrations. Current research is going to optimize the assay conditions and validate the procedures for the routine application in clinical laboratories.

  8. Characterization of Binding Epitopes of CA125 Monoclonal Antibodies

    DEFF Research Database (Denmark)

    Marcos-Silva, Lara; Narimatsu, Yoshiki; Halim, Adnan

    2014-01-01

    The most used cancer serum biomarker is the CA125 immunoassay for ovarian cancer that detects the mucin glycoprotein MUC16. Several monoclonal antibodies (mAbs) including OC125 and M11 are used in CA125 assays. However, despite considerable efforts, our knowledge of the molecular characteristics...

  9. The development and current status of the technology of isotope and radiation in China

    Energy Technology Data Exchange (ETDEWEB)

    Jinrong, Z. [China Institute of Atomic Energy, Beijing, (China). Department of Isotopes

    1997-10-01

    The research and applications of isotope technology and radiation sources in China are presented. Many effort were directed towards production of radiopharmaceuticals, radiation sources, radiation treatment and radioactive tracers. Reactor and accelerator produced radioisotopes contributed to and will further accelerate the development of nuclear medicine in China. Recently, much attention has been paid on tumor therapy mainly with radiolabelled monoclonal antibody, radiolabelled microsphere and colloid, bone-seeking agents, and radiolabelled Octreotide. Radioimmunoassay has been widely used with many convenient kits available. There are above 30 radioimmunoassay kit produces and more than 60 radioimmunoassay centers. Recently the advance is mainly in solid-phase separation process and in radioimmunoassay method, including some nonradioactive immunoassay methods, such as enzyme immunoassay, fluorescence immunoassay, and chemiluminescence immunoassay. Kits for enzyme immunoassay have been put into clinical use. Various radiation sources are produced for medical purposes and for use in nuclear power stations 4 refs., 8 tabs.

  10. The development and current status of the technology of isotope and radiation in China

    International Nuclear Information System (INIS)

    Jinrong, Z.

    1997-01-01

    The research and applications of isotope technology and radiation sources in China are presented. Many effort were directed towards production of radiopharmaceuticals, radiation sources, radiation treatment and radioactive tracers. Reactor and accelerator produced radioisotopes contributed to and will further accelerate the development of nuclear medicine in China. Recently, much attention has been paid on tumor therapy mainly with radiolabelled monoclonal antibody, radiolabelled microsphere and colloid, bone-seeking agents, and radiolabelled Octreotide. Radioimmunoassay has been widely used with many convenient kits available. There are above 30 radioimmunoassay kit produces and more than 60 radioimmunoassay centers. Recently the advance is mainly in solid-phase separation process and in radioimmunoassay method, including some nonradioactive immunoassay methods, such as enzyme immunoassay, fluorescence immunoassay, and chemiluminescence immunoassay. Kits for enzyme immunoassay have been put into clinical use. Various radiation sources are produced for medical purposes and for use in nuclear power stations

  11. Development of a sensitive Luminex xMAP-based microsphere immunoassay for specific detection of Iris yellow spot virus.

    Science.gov (United States)

    Yu, Cui; Yang, Cuiyun; Song, Shaoyi; Yu, Zixiang; Zhou, Xueping; Wu, Jianxiang

    2018-04-04

    Iris yellow spot virus (IYSV) is an Orthotospovirus that infects most Allium species. Very few approaches for specific detection of IYSV from infected plants are available to date. We report the development of a high-sensitive Luminex xMAP-based microsphere immunoassay (MIA) for specific detection of IYSV. The nucleocapsid (N) gene of IYSV was cloned and expressed in Escherichia coli to produce the His-tagged recombinant N protein. A panel of monoclonal antibodies (MAbs) against IYSV was generated by immunizing the mice with recombinant N protein. Five specific MAbs (16D9, 11C6, 7F4, 12C10, and 14H12) were identified and used for developing the Luminex xMAP-based MIA systems along with a polyclonal antibody against IYSV. Comparative analyses of their sensitivity and specificity in detecting IYSV from infected tobacco leaves identified 7F4 as the best-performed MAb in MIA. We then optimized the working conditions of Luminex xMAP-based MIA in specific detection of IYSV from infected tobacco leaves by using appropriate blocking buffer and proper concentration of biotin-labeled antibodies as well as the suitable ratio between the antibodies and the streptavidin R-phycoerythrin (SA-RPE). Under the optimized conditions the Luminex xMAP-based MIA was able to specifically detect IYSV with much higher sensitivity than conventional enzyme-linked immunosorbent assay (ELISA). Importantly, the Luminex xMAP-based MIA is time-saving and the whole procedure could be completed within 2.5 h. We generated five specific MAbs against IYSV and developed the Luminex xMAP-based MIA method for specific detection of IYSV in plants. This assay provides a sensitive, high-specific, easy to perform and likely cost-effective approach for IYSV detection from infected plants, implicating potential broad usefulness of MIA in plant virus diagnosis.

  12. USE OF AN INDIRECT ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA TO DETECT ANTIBODIES IN AYU (Plecogiossus altivelis VACCINATED BY IMMERSION ADMINISTRATION

    Directory of Open Access Journals (Sweden)

    . Sukenda

    2007-05-01

    Full Text Available ABSTRACTAn indirect enzyme-linked immunosorbent assay (ELISA was used to detect serum antibody in ayu, Plecoglossus altivelis, immunized against Pseudomonasplecoglossicida by immersion vaccination.  First, the procedure of the ELISA was optimized and the sensitivity was checked.  Secondly, the formalin-killed cells (FKC of P. plecoglossicida was administered to ayu by immersion vaccination.  Two weeks after vaccination, fish were divided into two groups, one group was given booster.  The level of specific antibody production of both boostered and vaccinated only fish were statistically higher than unvaccinated control fish at the time of each blood collection.  However, the differences between the boostered and vaccinated only fish were not statistically significant.Keywords :  immunization, Pseudomonas plecoglossicida, ayu, ELISA ABSTRAKIndirect enzyme-linked immunosorbent assay (ELISA digunakan untuk mendeteksi antibodi pada ayu, Plecoglossus altivelis, yang diimunisasi dengan cara perendaman untuk melawan infeksi Pseudomonas plecoglossicida.  Pertama, prosedur ELISA dioptimasikan dan sensitivitas dari metode ini juga diperiksa.  Kemudian, bakteri Plecoglossus altivelis yang sudah dimatikan dengan formalin diberikan ke ikan ayu dengan vaksinasi perendaman.  Dua minggu setelah vaksinasi, ikan dibagi menjadi dua kelompok, satu kelompok diberi vaksinasi kedua.  Produksi antibodi spesifik dari ikan-ikan yang divaksinasi satu kali dengan vaksinasi dua kaii secara statistik lebih tinggi dibandingkan dengan control.  Akan tetapi, tidak ada perbedaan produksi antibodi antara ikan yarig divaksanisi satu kali dengan divaksinasi dua kali.Kata kunci :  imunisasi, Pseudomonasplecoglossicida, ayu, ELISA

  13. Evaluation of the Cross-reactivity of Antidrug Antibodies to CT-P13 and Infliximab Reference Product (Remicade): An Analysis Using Immunoassays Tagged with Both Agents.

    Science.gov (United States)

    Reinisch, Walter; Jahnsen, Jørgen; Schreiber, Stefan; Danese, Silvio; Panés, Julián; Balsa, Alejandro; Park, Won; Kim, JiSoo; Lee, Jee Un; Yoo, Dae Hyun

    2017-06-01

    During two pivotal clinical trials of the infliximab biosimilar CT-P13 (PLANETAS and PLANETRA), antidrug antibodies (ADAs) and neutralising antibodies (NAbs) were detected in the sera of patients treated with CT-P13 and the reference product (RP; Remicade). The aim was to assess the comparability of Remicade- and CT-P13-tagged immunoassays for the detection of ADAs and NAbs using data from these trials, in order to determine the cross-reactivity of CT-P13 and RP ADAs. Sera from patients with rheumatoid arthritis and ankylosing spondylitis were analysed using an electrochemiluminescence (ECL) bridging assay or Gyros immunoassay, tagged with Remicade or CT-P13 at screening, weeks 14, 30 and 54, and the end of study visit. NAb titre was compared at screening and weeks 14 and 30. The proportion of cross-reactive samples was determined and an inter-rater agreement analysis performed to assess the concordance of results between assays. In PLANETAS, 93.1% (94/101) of RP ADA-positive samples and 93.0% (93/100) of RP NAb-positive samples cross-reacted with CT-P13; 99.0% (103/104) of CT-P13 ADA-positive and 98.0% (98/100) of CT-P13 NAb-positive samples cross-reacted with the RP. In PLANETRA, 94.7% (426/450) of RP ADA-positive samples and 94.3% (415/440) of RP NAb-positive samples cross-reacted with CT-P13, and 96.6% (458/474) of CT-P13 ADA-positive and 96.4% (452/469) of CT-P13 NAb-positive samples cross-reacted with the RP. In both studies, there was strong agreement in outcome between assays at all post-screening time points (PLANETAS: Cohen's κ 0.89-0.98 for ADA, 0.86-0.98 for NAb; PLANETRA: 0.92-0.94 for both ADA and NAb, all p PLANETAS: Spearman's ρ 0.73 and 0.74, respectively; PLANETRA: 0.61 and 0.72, respectively; all p < 0.001). This study has demonstrated that ADAs and NAbs against CT-P13 and RP are cross-reactive, indicating that CT-P13 and RP share immunodominant epitopes.

  14. Development of enzyme linked immunosorbent assay (ELISA) for the detection of root-knot nematode Meloidogyne incognita.

    Science.gov (United States)

    Kapur-Ghai, J; Kaur, M; Goel, P

    2014-09-01

    Root-knot nematodes (Meloidogyne incognita) are obligate, sedentary plant endoparasites that are extremely polyphagous in nature and cause severe economic losses in agriculture. Hence, it is essential to control the parasite at an early stage. For any control strategy to be effective, an early and accurate diagnosis is of paramount importance. Immunoassays have the inherent advantages of sensitivity and specificity; have the potential to identify and quantify these plant-parasitic nematodes. Hence, in the present studies, enzyme-linked immunosorbent assay (ELISA) has been developed for the detection of M.incognita antigens. First an indirect ELISA was developed for detection and titration of anti-M.incognita antibodies. Results indicated as high as 320 K titre of the antisera. Finally competitive inhibition ELISA was developed employing these anti-M.incognita antibodies for detection of M.incognita antigens. Sensitivity of ELISA was 10 fg. Competitive inhibition ELISA developed in the present studies has the potential of being used as an easy, rapid, specific and sensitive diagnostic tool for the detection of M.incognita infection.

  15. Genus and species-specific IgG and IgM antibodies pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Butt, T.; Abbassi, S.A.; Ahmad, R.N.; Mahmood, A.; Karamat, K.A; Malik, H.S.; Anwar, M.

    2004-01-01

    Objective: To evaluate three different enzyme immunoassays for serological diagnosis of pulmonary tuberculosis and to compare their diagnostic accuracy in different combinations. Subjects and Methods: Sera from patients suffering from pulmonary tuberculosis (n=94) with sputum positive for acid fast bacilli (AFB) and sera from control group of healthy individuals (n=90) with sputum negative for AFB were tested by Pathozyme-Myco G EIA, Pathozyme-TB Complex Plus EIA and Pathozyme Myco M EIA kits for the genus-specific IgG and IgM, and the species-specific IgG antibodies against antigens of Mycobacterium tuberculosis. Results: The detection of IgG against genus-specific antigens by Pathozyme-Myco G had a sensitivity of 46% and a specificity of 93%, of IgG against species-specific antigens by Pathozyme- TB Complex Plus had a sensitivity of 64% and specificity of 97% and of IgM against genus-specific antigens by Pathozyme Myco M had a sensitivity of 67% and specificity of 98%. When the results of these immunoassays were evaluated in combination, their sensitivity improved. Combination of genus-specific IgM and species-specific IgG yielded best results with a sensitivity of 87% and specificity of 93%. Conclusion: The sensitivity of serological diagnosis of tuberculosis is low, but it can be increased by utilizing a combination of several antigens. (author)

  16. Dot immunoassay for the simultaneous determination of postvaccination immunity against pertussis, diphtheria, and tetanus.

    Science.gov (United States)

    Khramtsov, Pavel; Bochkova, Maria; Timganova, Valeria; Zamorina, Svetlana; Rayev, Mikhail

    2017-06-01

    A dot immunoassay for simultaneous semiquantitative detection of IgG against tetanus toxoid (Ttx) and diphtheria toxoid (Dtx) and qualitative detection of anti-Bordetella pertussis IgGs in human blood serum using carbon nanoparticles functionalized with streptococcal protein G was developed. Inactivated B. pertussis cells in suspension form were used as an antigen in the immunoassay. Pertussis, tetanus, and diphtheria antigens were separately spotted onto nitrocellulose strips, and then the immunostrips were successively incubated with blood sera and a suspension of carbon nanoparticles. The immunostrips were then scanned with a flatbed scanner, and the images obtained were processed with ImageJ. One hundred fifty-five venous blood serum samples from children vaccinated with diphtheria, tetanus, and whole-cell pertussis (DTwP) vaccine were tested in comparison with a conventional ELISA and agglutination test. The total time required for analysis of 32 serum samples was less than 3 h. Comparison between the results of the dot immunoassay and the corresponding ELISA/agglutination test revealed a high level of agreement (Cohen's kappa between 0.765 and 0.813). The lower limit of quantification was 0.06 IU/ml for anti-Ttx and anti-Dtx. The intra-assay coefficients of variation were less than 15% for anti-Ttx and anti-Dtx and less than 10% for anti-pertussis. The diagnostic sensitivity of detection of the antibody protection level was 93.5% for anti-Ttx [95% confidence interval (CI) 83.5-97.9%], 92.4% for anti-Dtx (95% CI 80.9297.5%), and 90.2% for anti-pertussis (95% CI 75.9-96.8%). The diagnostic specificity was 90.9% for anti-Ttx (95% CI 57.1-99.5%), 85% for anti-Dtx (95% CI 61.1-96.0%), and 89.3% for anti-pertussis (95%CI 80.8-94.5%). The dot immunoassay developed does not require expensive reading equipment, and allows detection of antibodies against three antigens in a single analysis. The immunostrips can be stored for a long time without changes in the

  17. Highly sensitive immunoassay of protein molecules based on single nanoparticle fluorescence detection in a nanowell

    Science.gov (United States)

    Han, Jin-Hee; Kim, Hee-Joo; Lakshmana, Sudheendra; Gee, Shirley J.; Hammock, Bruce D.; Kennedy, Ian M.

    2011-03-01

    A nanoarray based-single molecule detection system was developed for detecting proteins with extremely high sensitivity. The nanoarray was able to effectively trap nanoparticles conjugated with biological sample into nanowells by integrating with an electrophoretic particle entrapment system (EPES). The nanoarray/EPES is superior to other biosensor using immunoassays in terms of saving the amounts of biological solution and enhancing kinetics of antibody binding due to reduced steric hindrance from the neighboring biological molecules. The nanoarray patterned onto a layer of PMMA and LOL on conductive and transparent indium tin oxide (ITO)-glass slide by using e-beam lithography. The suspension of 500 nm-fluorescent (green emission)-carboxylated polystyrene (PS) particles coated with protein-A followed by BDE 47 polyclonal antibody was added to the chip that was connected to the positive voltage. The droplet was covered by another ITO-coated-glass slide and connected to a ground terminal. After trapping the particles into the nanowells, the solution of different concentrations of anti-rabbit- IgG labeled with Alexa 532 was added for an immunoassay. A single molecule detection system could quantify the anti-rabbit IgG down to atto-mole level by counting photons emitted from the fluorescent dye bound to a single nanoparticle in a nanowell.

  18. Development of a monoclonal-based enzyme-linked immunoassay for saxitoxin-induced protein.

    Science.gov (United States)

    Smith, D S; Kitts, D D

    1994-03-01

    A monoclonal antibody was generated against saxitoxin-induced protein (SIP) from the small shore crab Hemigrapsus oregenesis. SIP was induced by saxitoxin injection and could be detected in the crude crab extracts with both polyclonal and monoclonal antibody preparations. On Western blots, the polyclonal serum reacted against several bands which were induced by saxitoxin in the crude extracts. These bands represented proteins related to SIP. The monoclonal (4G5), however, was specific for the 79,000 mol. wt subunit of SIP. A triple antibody sandwich ELISA was developed in which polyclonal anti-SIP IgG was used as a trapping layer and monoclonal 4G5 was used as the detection layer. This assay was shown to be more specific and more accurate than a direct bind assay which employed the polyclonal antiserum alone. Although the polyclonal serum was more sensitive than the monoclonal on Western blots, the triple antibody sandwich and direct bind ELISAs were of comparable sensitivity.

  19. Chemiluminescence Immunoassay for the Detection of Antibodies against the 2C and 3ABC Nonstructural Proteins Induced by Infecting Pigs with Foot-and-Mouth Disease Virus.

    Science.gov (United States)

    Liu, Zezhong; Shao, Junjun; Zhao, Furong; Zhou, Guangqing; Gao, Shandian; Liu, Wei; Lv, Jianliang; Li, Xiumei; Li, Yangfan; Chang, Huiyun; Zhang, Yongguang

    2017-08-01

    The potential diagnostic value of chemiluminescence immunoassays (CLIAs) has been accepted in recent years, although their use for foot-and-mouth disease (FMD) diagnostics has not been reported. Full-length 3ABC and 2C proteins were expressed in bacteria and purified by affinity chromatography to develop a rapid and accurate approach to distinguish pigs infected with foot-and-mouth disease virus (FMDV) from vaccinated pigs. The recombinant proteins were then used as antigens to develop two CLIAs for the detection of antibodies against nonstructural viral proteins. The diagnostic performance of the two assays was compared by analyzing serum from pigs (naive pigs, n = 63; vaccinated, uninfected pigs, n = 532; naive, infected pigs, n = 117) with a known infection status. The 3ABC-2C CLIA had a higher accuracy rate, with a diagnostic sensitivity of 100% and a diagnostic specificity of 96.5%, than the 3ABC CLIA, which had a diagnostic sensitivity of 95.7% and a diagnostic specificity of 96.0%. The results of the 3ABC-2C CLIA also had a high rate of concordance with those of two commercial FMDV enzyme-linked immunosorbent assay (ELISA) kits used to assess serum collected from 962 pigs in the field (96.2% and 97.8%, respectively). The 3ABC-2C CLIA detected infection in serum samples from infected pigs earlier than the commercial ELISA kits. In addition, the 3ABC-2C CLIA produced results within 15 min. On the basis of these findings, the 3ABC-2C CLIA could serve as the foundation for the development of penside FMD diagnostics and offers an alternative method to detect FMDV infections. Copyright © 2017 American Society for Microbiology.

  20. evaluation of a rapid test for hiv antibodies in saliva and blood

    African Journals Online (AJOL)

    To test whole blood and saliva for HIV antibodies. (anti-HIV) using a rapid test strip capillary flow . immunoassay ... Design. A prospective pilot study of selected HIV-positive and ... defined by the underlying illness or condition is illustrated in.

  1. Synthesis of polycyclic aromatic hydrocarbon-protein conjugates for preparation and immunoassay of antibodies.

    Science.gov (United States)

    Glushkov, Andrey N; Kostyanko, Mikhail V; Cherno, Sergey V; Vasilchenko, Ilya L

    2002-04-01

    The method is described dealing with the synthesis of conjugates protein-polycyclic aromatic hydrocarbons (PAHs), highly soluble in water, stable without special stabilizers and containing the minimum quantity of cross-linked products. The reaction of protein with PAH containing an aldehyde group, has been carried out in an alkaline solution, and stabilization of the conjugate has been achieved by reduction with sodium borohydride in the presence of a compound blocking the formation of an insoluble polymeric fraction. The efficiency of synthesized conjugates for the induction and immunoassay of Abs to PAH for benzo[a]pyrene is shown.

  2. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Science.gov (United States)

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933, and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli. PMID:22919675

  3. Mycobacterium tuberculosis lipolytic enzymes as potential biomarkers for the diagnosis of active tuberculosis.

    Directory of Open Access Journals (Sweden)

    Belinda Brust

    Full Text Available BACKGROUND: New diagnosis tests are urgently needed to address the global tuberculosis (TB burden and to improve control programs especially in resource-limited settings. An effective in vitro diagnostic of TB based on serological methods would be regarded as an attractive progress because immunoassays are simple, rapid, inexpensive, and may offer the possibility to detect cases missed by standard sputum smear microscopy. However, currently available serology tests for TB are highly variable in sensitivity and specificity. Lipolytic enzymes have recently emerged as key factors in lipid metabolization during dormancy and/or exit of the non-replicating growth phase, a prerequisite step of TB reactivation. The focus of this study was to analyze and compare the potential of four Mycobacterium tuberculosis lipolytic enzymes (LipY, Rv0183, Rv1984c and Rv3452 as new markers in the serodiagnosis of active TB. METHODS: Recombinant proteins were produced and used in optimized ELISA aimed to detect IgG and IgM serum antibodies against the four lipolytic enzymes. The capacity of the assays to identify infection was evaluated in patients with either active TB or latent TB and compared with two distinct control groups consisting of BCG-vaccinated blood donors and hospitalized non-TB individuals. RESULTS: A robust humoral response was detected in patients with active TB whereas antibodies against lipolytic enzymes were infrequently detected in either uninfected groups or in subjects with latent infection. High specifity levels, ranging from 93.9% to 97.5%, were obtained for all four antigens with sensitivity values ranging from 73.4% to 90.5%, with Rv3452 displaying the highest performances. Patients with active TB usually exhibited strong IgG responses but poor IgM responses. CONCLUSION: These results clearly indicate that the lipolytic enzymes tested are strongly immunogenic allowing to distinguish active from latent TB infections. They appear as potent

  4. Trends in interfacial design for surface plasmon resonance based immunoassays

    International Nuclear Information System (INIS)

    Shankaran, Dhesingh Ravi; Miura, Norio

    2007-01-01

    Immunosensors based on surface plasmon resonance (SPR) have become a promising tool in sensor technology for biomedical, food, environmental, industrial and homeland security applications. SPR is a surface sensitive optical technique, suitable for real-time and label-free analysis of biorecognition events at functional transducer surfaces. Fabrication of highly active and robust sensing surfaces is an important part in immunoassays because the quality, quantity, chemistry and topography of the interfacial biomembranes play a major role in immunosensor performance. Eventually, a variety of immobilization methods such as physical adsorption, covalent coupling, Langmuir-Blodgett film, polymer thin film, self-assembly, sol-gel, etc, have been introduced over the years for the immobilization of biomolecules (antibody or antigen) on the transducer surfaces. The selection of an immobilization method for an immunoassay is governed by several factors such as nature and stability of the biomolecules, target analyte, application, detection principle, mode of signal transduction, matrix complexity, etc. This paper provides an overview of the various surface modification methods for SPR based immunosensor fabrication. The preparation, structure and application of different functional interfacial surfaces have been discussed along with a brief introduction to the SPR technology, biomolecules and detection principles. (review article)

  5. Trends in interfacial design for surface plasmon resonance based immunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Shankaran, Dhesingh Ravi [Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga-shi, Fukuoka, 816-8580 (Japan); Miura, Norio [Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga-shi, Fukuoka, 816-8580 (Japan)

    2007-12-07

    Immunosensors based on surface plasmon resonance (SPR) have become a promising tool in sensor technology for biomedical, food, environmental, industrial and homeland security applications. SPR is a surface sensitive optical technique, suitable for real-time and label-free analysis of biorecognition events at functional transducer surfaces. Fabrication of highly active and robust sensing surfaces is an important part in immunoassays because the quality, quantity, chemistry and topography of the interfacial biomembranes play a major role in immunosensor performance. Eventually, a variety of immobilization methods such as physical adsorption, covalent coupling, Langmuir-Blodgett film, polymer thin film, self-assembly, sol-gel, etc, have been introduced over the years for the immobilization of biomolecules (antibody or antigen) on the transducer surfaces. The selection of an immobilization method for an immunoassay is governed by several factors such as nature and stability of the biomolecules, target analyte, application, detection principle, mode of signal transduction, matrix complexity, etc. This paper provides an overview of the various surface modification methods for SPR based immunosensor fabrication. The preparation, structure and application of different functional interfacial surfaces have been discussed along with a brief introduction to the SPR technology, biomolecules and detection principles. (review article)

  6. A membrane-based ELISA assay for the herbicide Isoproturon in soil samples

    OpenAIRE

    Baskeyfield, Damian E. H.; Davis, Frank; Magan, Naresh; Tothill, Ibtisam E.

    2012-01-01

    A membrane based enzyme linked immunosorbent assay (MELISA) for the detection of a common herbicide, isoproturon is described. A heterogeneous competitive ELISA was the format chosen for isoproturon detection. An immunoassay system with a horseradish peroxidase (HRP) labeled polyclonal antibody preparation was developed and characterized before suitable sensitivity and selectivity for isoproturon were attained. After development as a microtiter plate immunoassay, the system was transferred to...

  7. Anti-soluble liver antigen/liver-pancreas (SLA/LP) antibodies in pediatric patients with autoimmune hepatitis.

    Science.gov (United States)

    Vitozzi, Susana; Djilali-Saiah, Idriss; Lapierre, Pascal; Alvarez, Fernando

    2002-12-01

    Antibodies against soluble liver antigen/liver-pancreas (SLA/LP) have been associated with severe autoimmune hepatitis (AIH) and poor outcome, but most of these reports have focused on adult patients. The aim of this study was to assess the prevalence and clinical significance of anti-SLA/LP antibodies in a pediatric population with AIH. We developed a quantitative enzyme-linked immunoassay (ELISA), a Western blot (WB) and an immunoprecipitation assay (IPA) based on recombinant cDNA from activated Jurkat cells. The specificity of these tests was validated by testing 200 serum samples from healthy subjects, and from patients with liver and non-liver diseases. Anti-SLA/LP antibodies were found in patients with type 1 and type 2 AIH. The prevalence of these antibodies in patients with type 1 AIH was: 42% when tested by ELISA, 15% by WB and 50% by IPA. In patients with type 2 AIH, the prevalence rates were 42% by ELISA, 18% by WB and 44% by IPA. The mean titer values for anti-SLA/LP antibodies was significantly higher in type 2 AIH (1:1,300 +/- 339) than in type 1 AIH (1:600 +/- 71; p LKM1) and anti-liver cytosol type 1 (LC1) antibodies in sera. The presence of anti-SLA/LP showed a significant female preponderance in type 1 and 2 AIH patients (p = 0.0003 and p = 0.003, respectively), and was significantly correlated with a lower age at diagnosis (p = 0.05) in type 1 AIH patients. In conclusion, anti-SLA/LP antibodies in pediatric patients are associated with both type 1 and 2 AIH.

  8. Solid-Phase Immunoassay of Polystyrene-Encapsulated Semiconductor Coreshells for Cardiac Marker Detection

    Directory of Open Access Journals (Sweden)

    Sanghee Kim

    2012-01-01

    Full Text Available A solid-phase immunoassay of polystyrene-encapsulated semiconductor nanoparticles was demonstrated for cardiac troponin I (cTnI detection. CdSe/ZnS coreshells were encapsulated with a carboxyl-functionalized polystyrene nanoparticle to capture the target antibody through a covalent bonding and to eliminate the photoblinking and toxicity of semiconductor luminescent immunosensor. The polystyrene-encapsulated CdSe/ZnS fluorophores on surface-modified glass chip identified cTnI antigens at the level of ~ng/mL. It was an initial demonstration of diagnostic chip for monitoring a cardiovascular disease.

  9. Utility of HLA Antibody Testing in Kidney Transplantation

    Science.gov (United States)

    Konvalinka, Ana

    2015-01-01

    HLA antigens are polymorphic proteins expressed on donor kidney allograft endothelium and are critical targets for recipient immune recognition. HLA antibodies are risk factors for acute and chronic rejection and allograft loss. Solid-phase immunoassays for HLA antibody detection represent a major advance in sensitivity and specificity over cell-based methods and are widely used in organ allocation and pretransplant risk assessment. Post-transplant, development of de novo donor–specific HLA antibodies and/or increase in donor-specific antibodies from pretransplant levels are associated with adverse outcomes. Although single antigen bead assays have allowed sensitive detection of recipient HLA antibodies and their specificities, a number of interpretive considerations must be appreciated to understand test results in clinical and research contexts. This review, which is especially relevant for clinicians caring for transplant patients, discusses the technical aspects of single antigen bead assays, emphasizes their quantitative limitations, and explores the utility of HLA antibody testing in identifying and managing important pre- and post-transplant clinical outcomes. PMID:25804279

  10. Surface immobilized antibody orientation determined using ToF-SIMS and multivariate analysis.

    Science.gov (United States)

    Welch, Nicholas G; Madiona, Robert M T; Payten, Thomas B; Easton, Christopher D; Pontes-Braz, Luisa; Brack, Narelle; Scoble, Judith A; Muir, Benjamin W; Pigram, Paul J

    2017-06-01

    Antibody orientation at solid phase interfaces plays a critical role in the sensitive detection of biomolecules during immunoassays. Correctly oriented antibodies with solution-facing antigen binding regions have improved antigen capture as compared to their randomly oriented counterparts. Direct characterization of oriented proteins with surface analysis methods still remains a challenge however surface sensitive techniques such as Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) provide information-rich data that can be used to probe antibody orientation. Diethylene glycol dimethyl ether plasma polymers (DGpp) functionalized with chromium (DGpp+Cr) have improved immunoassay performance that is indicative of preferential antibody orientation. Herein, ToF-SIMS data from proteolytic fragments of anti-EGFR antibody bound to DGpp and DGpp+Cr are used to construct artificial neural network (ANN) and principal component analysis (PCA) models indicative of correctly oriented systems. Whole antibody samples (IgG) test against each of the models indicated preferential antibody orientation on DGpp+Cr. Cross-reference between ANN and PCA models yield 20 mass fragments associated with F(ab') 2 region representing correct orientation, and 23 mass fragments associated with the Fc region representing incorrect orientation. Mass fragments were then compared to amino acid fragments and amino acid composition in F(ab') 2 and Fc regions. A ratio of the sum of the ToF-SIMS ion intensities from the F(ab') 2 fragments to the Fc fragments demonstrated a 50% increase in intensity for IgG on DGpp+Cr as compared to DGpp. The systematic data analysis methodology employed herein offers a new approach for the investigation of antibody orientation applicable to a range of substrates. Controlled orientation of antibodies at solid phases is critical for maximizing antigen detection in biosensors and immunoassays. Surface-sensitive techniques (such as ToF-SIMS), capable of direct

  11. Proximity hybridization-regulated catalytic DNA hairpin assembly for electrochemical immunoassay based on in situ DNA template-synthesized Pd nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Fuyi [School of Chemistry and Chemical Engineering, Jiangsu Normal University, Xuzhou 221116 (China); Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Department of Pharmaceutical Analysis, School of Pharmacy, Xuzhou Medical College, 221004, Xuzhou (China); Yao, Yao; Luo, Jianjun; Zhang, Xing; Zhang, Yu; Yin, Dengyang [Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Department of Pharmaceutical Analysis, School of Pharmacy, Xuzhou Medical College, 221004, Xuzhou (China); Gao, Fenglei, E-mail: jsxzgfl@sina.com [Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Department of Pharmaceutical Analysis, School of Pharmacy, Xuzhou Medical College, 221004, Xuzhou (China); Wang, Po, E-mail: wangpo@jsnu.edu.cn [School of Chemistry and Chemical Engineering, Jiangsu Normal University, Xuzhou 221116 (China)

    2017-05-29

    Novel hybridization proximity-regulated catalytic DNA hairpin assembly strategy has been proposed for electrochemical immunoassay based on in situ DNA template-synthesized Pd nanoparticles as signal label. The DNA template-synthesized Pd nanoparticles were characterized with atomic force microscopic and X-ray photoelectron spectroscopy. The highly efficient electrocatalysis by DNA template synthesized Pd nanoparticles for NaBH{sub 4} oxidation produced an intense detection signal. The label-free electrochemical method achieved the detection of carcinoembryonic antigen (CEA) with a linear range from 10{sup −15} to 10{sup −11} g mL{sup −1} and a detection limit of 0.43 × 10{sup −15} g mL{sup −1}. Through introducing a supersandwich reaction to increase the DNA length, the electrochemical signal was further amplified, leading to a detection limit of 0.52 × 10{sup −16} g mL{sup −1}. And it rendered satisfactory analytical performance for the determination of CEA in serum samples. Furthermore, it exhibited good reproducibility and stability; meanwhile, it also showed excellent specificity due to the specific recognition of antigen by antibody. Therefore, the DNA template synthesized Pd nanoparticles based signal amplification approach has great potential in clinical applications and is also suitable for quantification of biomarkers at ultralow level. - Graphical abstract: A novel label-free and enzyme-free electrochemical immunoassay based on proximity hybridization-regulated catalytic DNA hairpin assemblies for recycling of the CEA. - Highlights: • A novel enzyme-free electrochemical immunosensor was developed for detection of CEA. • The signal amplification was based on catalytic DNA hairpin assembly and DNA-template-synthesized Pd nanoparticles. • The biosensor could detect CEA down to 0.52 × 10{sup −16} g mL{sup −1} level with a dynamic range spanning 5 orders of magnitude.

  12. Development, evaluation, and laboratory validation of immunoassays for the diagnosis of equine infectious anemia (EIA) using recombinant protein produced from a synthetic p26 gene of EIA virus.

    Science.gov (United States)

    Singha, Harisankar; Goyal, Sachin K; Malik, Praveen; Khurana, Sandip K; Singh, Raj K

    2013-12-01

    Equine infectious anemia (EIA)-a retroviral disease caused by equine infectious anemia virus (EIAV)-is a chronic, debilitating disease of horses, mules, and donkeys. EIAV infection has been reported worldwide and is recognized as pathogen of significant economic importance to the horse industry. This disease falls under regulatory control program in many countries including India. Control of EIA is based on identification of inapparent carriers by detection of antibodies to EIAV in serologic tests and "Stamping Out" policy. The current internationally accepted test for diagnosis of EIA is the agar gel immune-diffusion test (AGID), which detects antibodies to the major gag gene (p26) product. The objective of this study was to develop recombinant p26 based in-house immunoassays [enzyme linked immunosorbent assays (ELISA), and AGID] for EIA diagnosis. The synthetic p26 gene of EIAV was expressed in Escherichia coli and diagnostic potential of recombinant p26 protein were evaluated in ELISA and AGID on 7,150 and 1,200 equine serum samples, respectively, and compared with commercial standard AGID kit. The relative sensitivity and specificity of the newly developed ELISA were 100 and 98.6 %, respectively. Whereas, relative sensitivity and specificity of the newly developed AGID were in complete agreement in respect to commercial AGID kit. Here, we have reported the validation of an ELISA and AGID on large number of equine serum samples using recombinant p26 protein produced from synthetic gene which does not require handling of pathogenic EIAV. Since the indigenously developed reagents would be economical than commercial diagnostic kit, the rp26 based-immunoassays could be adopted for the sero-diagnosis and control of EIA in India.

  13. Improving the sensitivity of immunoassay based on MBA-embedded Au@SiO2 nanoparticles and surface enhanced Raman spectroscopy

    Science.gov (United States)

    Wei, Chao; Xu, Min-Min; Fang, Cong-Wei; Jin, Qi; Yuan, Ya-Xian; Yao, Jian-Lin

    2017-03-01

    Traditional "sandwich" structure immunoassay is mainly based on the self-assembly of "antibody on solid substrate-antigen-antibody with nanotags" architectures, and the sensitivity of this strategy is critically depended on the surface enhanced Raman scattering (SERS) activities and stability of nanotags. Therefore, the rational design and fabrication on the SERS nanotags attracts the common interests to the bio-related detecting and imaging. Herein, silica encapsulated Au with mercaptobenzoic acid (MBA) core-shell nanoparticles (Au-MBA@SiO2) are fabricated instead of the traditional naked Au or Ag nanoparticles for the SERS-based immunoassay on human and mouse IgG antigens. The MBA molecules facilitate the formation of continuous pinhole-free silica shell and are also used as SERS labels. The silica shell is employed to protect MBA labels and to isolate Au core from the ambient solution for blocking the aggregation. This shell also played the similar role to BSA in inhibiting the nonspecific bindings, which allowed the procedures for constructing "sandwich" structures to be simplified. All of these merits of the Au-MBA@SiO2 brought the high performance in the related immunoassay. Benefiting from the introduction of silica shell to encapsulate MBA labels, the detection sensitivity was improved by about 1- 2 orders of magnitude by comparing with the traditional approach based on naked Au-MBA nanoparticles. This kind of label-embedded core-shell nanoparticles could be developed as the versatile nanotags for the bioanalysis and bioimaging.

  14. Fast conversion of scFv to Fab antibodies using type IIs restriction enzymes.

    Science.gov (United States)

    Sanmark, Hanna; Huovinen, Tuomas; Matikka, Tero; Pettersson, Tiina; Lahti, Maria; Lamminmäki, Urpo

    2015-11-01

    Single chain variable fragment (scFv) antibody libraries are widely used for developing novel bioaffinity reagents, although Fab or IgG molecules are the preferred antibody formats in many final applications. Therefore, rapid conversion methods for combining multiple DNA fragments are needed to attach constant domains to the scFv derived variable domains. In this study we describe a fast and easy cloning method for the conversion of single framework scFv fragments to Fab fragments using type IIS restriction enzymes. All cloning steps excluding plating of the Fab transformants can be done in 96 well plates and the procedure can be completed in one working day. The concept was tested by converting 69 scFv clones into Fab format on 96 well plates, which resulted in 93% success rate. The method is particularly useful as a high-throughput tool for the conversion of the chosen scFv clones into Fab molecules in order to analyze them as early as possible, as the conversion can significantly affect the binding properties of the chosen clones. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Applications of recombinant antibodies in plant pathology.

    Science.gov (United States)

    Ziegler, Angelika; Torrance, Lesley

    2002-09-01

    Summary Advances in molecular biology have made it possible to produce antibody fragments comprising the binding domains of antibody molecules in diverse heterologous systems, such as Escherichia coli, insect cells, or plants. Antibody fragments specific for a wide range of antigens, including plant pathogens, have been obtained by cloning V-genes from lymphoid tissue, or by selection from large naive phage display libraries, thus avoiding the need for immunization. The antibody fragments have been expressed as fusion proteins to create different functional molecules, and fully recombinant assays have been devised to detect plant viruses. The defined binding properties and unlimited cheap supply of antibody fusion proteins make them useful components of standardized immunoassays. The expression of antibody fragments in plants was shown to confer resistance to several plant pathogens. However, the antibodies usually only slowed the progress of infection and durable 'plantibody' resistance has yet to be demonstrated. In future, it is anticipated that antibody fragments from large libraries will be essential tools in high-throughput approaches to post-genomics research, such as the assignment of gene function, characterization of spatio-temporal patterns of protein expression, and elucidation of protein-protein interactions.

  16. Heparin-associated thrombocytopenia: antibody binding specificity to platelet antigens.

    Science.gov (United States)

    Lynch, D M; Howe, S E

    1985-11-01

    Sera from four patients with heparin-associated thrombocytopenia (HAT) were evaluated by a quantitative enzyme-linked immunosorbent assay (ELISA) to detect heparin-dependent serum platelet-bindable immunoglobulin (S-PBIg) and by Western blotting and immunoprecipitation to investigate the specificity of the antibody binding. All HAT sera showed mildly increased S-PBIg (mean, 7.8 fg per platelet; normal, less than 6.0 fg per platelet) to intact target platelets in the ELISA, which was markedly increased in the presence of heparin (mean, 20.9 fg per platelet). This increase was 20-fold greater than normal control sera, which showed a mean differential increase of only 0.5 fg per platelet. Immunoglobulin binding specificity to platelet antigens was investigated using sodium dodecyl sulfate-polyacrylamide gel electrophoresis of platelet lysate with transfer of the platelet fractions onto nitrocellulose strips (Western blotting) and subsequent immunoassay using HAT and normal sera. In the presence of heparin, the four HAT patients demonstrated increased binding of immunoglobulin to platelet antigens of apparent molecular weights of 180, 124, and 82 kd. Radiolabeled heparin when incubated with HAT sera, normal sera, or albumin blanks bound to platelet proteins of the same apparent molecular weights. These observations are consistent with current hypotheses suggesting that HAT antibody is directed to heparin-platelet complexes or, alternatively, that heparin induces conformational change of antigenic sites on the platelet membrane.

  17. Site-Selective Orientated Immobilization of Antibodies and Conjugates for Immunodiagnostics Development

    Science.gov (United States)

    Rusling, James

    2016-01-01

    Immobilized antibody systems are the key to develop efficient diagnostics and separations tools. In the last decade, developments in the field of biomolecular engineering and crosslinker chemistry have greatly influenced the development of this field. With all these new approaches at our disposal, several new immobilization methods have been created to address the main challenges associated with immobilized antibodies. Few of these challenges that we have discussed in this review are mainly associated to the site-specific immobilization, appropriate orientation, and activity retention. We have discussed the effect of antibody immobilization approaches on the parameters on the performance of an immunoassay. PMID:27876681

  18. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer

    Directory of Open Access Journals (Sweden)

    Xiaoling Fu

    2018-03-01

    Full Text Available The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA was presented for the clinical determination and analysis of human epididymis protein 4 (HE4 in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0–1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA, with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum. Keywords: Chemiluminescence immunoassay, Magnetic particles, Human epididymis protein 4

  19. Multiplex dipstick immunoassay for semi-quantitative determination of Fusarium mycotoxins in cereals

    International Nuclear Information System (INIS)

    Lattanzio, Veronica M.T.; Nivarlet, Noan; Lippolis, Vincenzo; Gatta, Stefania Della; Huet, Anne-Catherine; Delahaut, Philippe; Granier, Benoit; Visconti, Angelo

    2012-01-01

    Highlights: ► We developed a rapid method based on a multiplex dipstick immunoassay. ► The assay allowed the determination of major Fusarium toxins in wheat, oats, maize. ► We obtained cut off levels close to EU regulatory levels. - Abstract: A multiplex dipstick immunoassay based method for the simultaneous determination of major Fusarium toxins, namely zearalenone, T-2 and HT-2 toxins, deoxynivalenol and fumonisins in wheat, oats and maize has been developed. The dipstick format was based on an indirect competitive approach. Four test lines (mycotoxin–BSA conjugates) and one control line were located on the strip membrane. Labelled antibodies were freeze-dried within the microwell. Two matrix-related sample preparation protocols have been developed for wheat/oats (not containing fumonisins) and maize (containing fumonisins) respectively. The use of a methanol/water mixture for sample preparation allowed recoveries in the range 73–109% for all mycotoxins in all tested cereals, with relative standard deviation less than 10%. The optimized immunoassay was able to detect target mycotoxins at cut off levels equal to 80% of EU maximum permitted levels, i.e. 280, 400, 1400 and 3200 μg kg −1 , respectively, for zearalenone, T-2/HT-2 toxins, deoxynivalenol and fumonisins in maize, and 80, 400 and 1400 μg kg −1 , respectively, for zearalenone, T-2/HT-2 toxins and deoxynivalenol in wheat and oats. Analysis of naturally contaminated samples resulted in a good agreement between multiplex dipstick and validated confirmatory LC–MS/MS. The percentage of false positive results was less than or equal to 13%, whereas no false negative results were obtained. Data on the presence/absence of 6 mycotoxins at levels close to EU regulatory levels were obtained within 30 min. The proposed immunoassay protocol is rapid, inexpensive, easy-to-use and fit for purpose of rapid screening of mycotoxins in cereals.

  20. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    Science.gov (United States)

    Alderete, J F

    1984-06-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses during the development of lesions in animals inoculated subcutaneously and it reproducibly measured the individual classes immunoglobulins directed at T vaginalis. The colorimetric assay was also suitable for showing cross reactivity between trichomonal species as well as between different strains of T vaginalis. Conditions established for monitoring antibody to trichomanads in immunised rabbits or infected mice were equally effective for human materials, such as serum or vaginal washes. Serum from experimental animals or infected people showed high concentrations of IgG, IgA, and IgM antibody to trichomonads. Only antibodies of the IgG and IgA class were detected in vaginal washes from women with acute trichomoniasis. No IgE antibody to trichomonads was found under a variety of conditions in serum samples from patients or experimental animals.

  1. Bacteria that degrade hazardous waste: The isolation of trichloroethylene-degrading methanotrophic bacteria and development of monoclonal antibodies specific to them

    International Nuclear Information System (INIS)

    Little, C.D.

    1988-01-01

    Trichloroethylene (TCE), a suspected carcinogen, is one of the most frequently reported groundwater contaminants at hazardous waste sites in the US. An aerobic, methane-oxidizing bacterium was isolated that degrades TCE in pure culture at concentrations commonly observed in contaminated groundwater. Strain 46-1, a Type I methanotrophic bacterium, degraded TCE when growing on methane or methanol, producing CO 2 and water-soluble products. Gas chromatography and 14 C radiotracer techniques were used to determine the rate, methane dependence, and mechanism of TCE biodegradation. TCE biodegradation by strain 46-1 appears to be a co-metabolic process that occurs when the organism is actively metabolizing a suitable growth substrate such as methane or methanol. Five mouse monoclonal antibodies (MABS) that specifically bind strain 46-1 were prepared by conventional hybridoma technology. These MABS are apparently biochemically distinct and were used to develop enzyme-linked and fluorescent immunoassays to detect strain 46-1 cells in environmental samples. A fluorescent immunoassay utilizing four of these MABS easily distinguished laboratory-grown 46-1 cells from other methanotrophic and heterotrophic bacteria, but failed to detect 46-1 cells in groundwater samples and cultures

  2. ANTIBODIES TO BENZO[A]PYRENE AND POLYMORPHISMS OF CYP1A1*2A, CYP1A2*1F, GSTT1, AND GSTM1 GENES IN HEALTHY MEN AND LUNG CANCER PATIENTS

    Directory of Open Access Journals (Sweden)

    A. N. Glushkov

    2016-01-01

    Full Text Available Some genetic polymorphisms of CYP and GST enzymes metabolizing low-molecular weight xenobiotics may represent endogenous risk factors for carcinogenesis. However, possible relationships between the enzyme activities, amounts of carcinogen adducts and synthesis of anticarcinogen antibodies in humans (including cancer patients are still poorly studied. The purpose of this study was to identify possible associations between occurrence of antibodies against benzo[a]pyrene, and frequency of genetic polymorphisms of CYP1A1*2A, CYP1A2*1F, GSTT1, GSTM1 in healthy men and in lung cancer patients. Materials and methods. We have examined 203 men with non-small cell lung cancer and 267 apparently healthy donors without respiratory diseases. A non-competitive solid phase immunoassay of antibodies to benzo[a]pyrene was performed. Analysis of polymorphic loci within CYP1A1 (rs4646903, CYP1A2 (rs762551, GSTP1 (rs1695, rs1138272 was performed by means of real-time PCR using TaqMan technology. Null-alleles of GSTM1 (del, GSTT1 (del genes were detected by multiplex PCR with real-time fluorescent assay. Results. Among the lung cancer patients, the proportion of cases with a high level of IgG antibodies to benzo[a]pyrene in carriers of GSTT1+ and GSTM1+ in conjunction with the CYP1A2*1F C allele was significantly greater than in AA homozygotes CYP1A2*1F. The risk of lung cancer was increased to 5.5 in carriers of CYP1A2*1F C allele combined with GSTT1+ and GSTM1+ at high levels of IgG antibodies to benzo [a] pyrene. In healthy male donors, we have not found differences between the incidence of low and high levels of IgG anti-benzo[a]pyrene antibodies in the carriers of certain CYP1A1*2A, CYP1A2*1F, GSTT1 and GSTM1 genotypes. Conclusions. We have first reported a relationship between CYP1 and GST gene polymorphisms and specific immune response to chemical carcinogens in lung cancer patients. Immunoassays of IgG antibodies to benzo[a]pyrene combined with molecular

  3. Relation between enzyme-linked immunosorbent assay and radioimmunoassay for detection of antibodies to the capsular polysaccharide of Haemophilus influenzae type b

    International Nuclear Information System (INIS)

    Kristensen, K.; Weis Bentzon, M.

    1992-01-01

    The measurement of antibodies to the capsular polysaccharide (PRP) of Haemophilus influenzae type b (Hib) is important because vaccines inducing such antibodies are now available. We developed and evaluated an enzyme-linked immunosorbent assay (ELISA) for detection of these antibodies based on direct coating of the plates with tyraminated PRP. The assay fulfilled the requirements for parallel line assays; it was sensitive, specific, and reproducible with a coefficient of variation between days of 19%. Results from the ELISA were compared with results from radioimmunoassay and a correlation coefficient of 0.93 was found. Results obtained by the two methods were proportional and the relation was indepenedent of the antibody level. The relation between them was also unaffected by the contribution of different antibody isotypes, indicating that these were measured to the same extent by both methods. ELISA employing direct coating of the plates with tyraminated PRP represents a useful alternative for detection of antibodies when studying immunogenicity of Hib vaccines. (au)

  4. Comparison of Six Automated Treponema-Specific Antibody Assays.

    Science.gov (United States)

    Park, Borae G; Yoon, Jihoon G; Rim, John Hoon; Lee, Anna; Kim, Hyon-Suk

    2016-01-01

    Six different Treponema (TP)-specific immunoassays were compared to the fluorescent treponemal antibody absorption (FTA-ABS) test. A total of 615 samples were tested. The overall percent agreement, analytical sensitivity, and analytical specificity of each assay compared to the FTA-ABS test were as follows: Architect Syphilis TP, 99.2%, 96.8%, and 100%; Cobas Syphilis, 99.8%, 99.4%, and 100%; ADVIA Centaur Syphilis, 99.8%, 99.4%, and 100%; HISCL Anti-TP assay kit, 99.7%, 98.7%, and 100%; Immunoticles Auto3 TP, 99.0%, 97.5%, and 99.6%; Mediace TPLA, 98.0%, 98.1%, and 98.0%. All results that were discrepant between the TP-specific assays were associated with samples from noninfectious cases (11 immunoassay false positives and 7 from previous syphilis cases). Our study demonstrated that TP-specific immunoassays generally showed high sensitivities, specificities, and percentages of agreement compared to FTA-ABS, with rare cases of false-positive or false-negative results. Therefore, most TP-specific immunoassays are acceptable for use in screening for syphilis. However, it is important to perform a thorough review of a patient's clinical and treatment history for interpreting the results of syphilis serology. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  5. A Switchable Linker-Based Immunoassay for Ultrasensitive Visible Detection of Salmonella in Tomatoes.

    Science.gov (United States)

    Hahn, Jungwoo; Kim, Eunghee; You, Young Sang; Gunasekaran, Sundaram; Lim, Seokwon; Choi, Young Jin

    2017-10-01

    On-site detection for sensitive identification of foodborne pathogens on fresh produce with minimal use of specialized instrumentation is crucial to the food industry. A switchable linker (SL)-based immunoassay was designed for ultrasensitive on-site detection of Salmonella in tomato samples. The assay is based on large-scale aggregation of gold nanoparticles (GNPs), induced by a quantitative relationship among the biotinylated Salmonella polyclonal antibody (b-Ab) used as the SL, the functionalized GNPs, and Salmonella. Important factors such as the concentration of SLs, time required for large-scale aggregation, and selectivity of b-Ab were optimized to minimize the detection time (within 45 min with gentle agitation) and achieve the lowest limit of detection (LOD; 10 CFU/g in tomato samples) possible. This SL-based immunoassay with its relatively low LOD and short detection time may meet the need for rapid, simple, on-site analysis of pathogens in fresh produce. The novel switchable linker-based immunoassay is a rapid, specific, and sensitive method that has potential applications for routine diagnostics of Salmonella in tomato products. These advantages make it a practical approach for general use in the processing industry to detect Salmonella rapidly and to implement appropriate regulatory procedures. Furthermore, it could be applied to other fresh products including cantaloupe, strawberry, and cucumbers. © 2017 Institute of Food Technologists®.

  6. Patterned immobilization of antibodies within roll-to-roll hot embossed polymeric microfluidic channels.

    Directory of Open Access Journals (Sweden)

    Belachew Feyssa

    Full Text Available This paper describes a method for the patterned immobilization of capture antibodies into a microfluidic platform fabricated by roll-to-roll (R2R hot embossing on poly (methyl methacrylate (PMMA. Covalent attachment of antibodies was achieved by two sequential inkjet printing steps. First, a polyethyleneimine (PEI layer was deposited onto oxygen plasma activated PMMA foil and further cross-linked with glutaraldehyde (GA to provide an amine-reactive aldehyde surface (PEI-GA. This step was followed by a second deposition of antibody by overprinting on the PEI-GA patterned PMMA foil. The PEI polymer ink was first formulated to ensure stable drop formation in inkjet printing and the printed films were characterized using atomic force microscopy (AFM and X-ray photoelectron spectroscopy (XPS. Anti-CRP antibody was patterned on PMMA foil by the developed method and bonded permanently with R2R hot embossed PMMA microchannels by solvent bonding lamination. The functionality of the immobilized antibody inside the microfluidic channel was evaluated by fluorescence-based sandwich immunoassay for detection of C-reactive protein (CRP. The antibody-antigen assay exhibited a good level of linearity over the range of 10 ng/ml to 500 ng/ml (R(2 = 0.991 with a calculated detection limit of 5.2 ng/ml. The developed patterning method is straightforward, rapid and provides a versatile approach for creating multiple protein patterns in a single microfluidic channel for multiplexed immunoassays.

  7. Solid-phase enzyme immunoassay or radioimmunoassay for the detection of immune complexes based on their recognition by conglutinin: conglutinin-binding test

    International Nuclear Information System (INIS)

    Casali, P.; Bossus, A.; Carpentier, N.A.; Lambert, P.H.

    1977-01-01

    Bovine conglutinin was used in a solid-phase assay for the detection of immune complexes. In a first step, the tested serum sample was incubated in polypropylene tubes coated with conglutinin to allow C3-coated immune complexes to bind to solid-phase conglutinin. In a second step, the conglutinin-bound complexes were detected using an enzyme-conjugated or radiolabelled anti-immunoglobulin antibody. The conglutinin-binding (KgB) test did not suffer from the interference of DNA, heparin or endotoxins. Its limit of sensitivity for aggregated IgG was 3 μg/ml undiluted human serum. Immune complexes prepared in vitro using tetanus toxoid, or DNA, and corresponding antibodies in human sera could be detected at various antigen/antibody ratios and at antibody concentrations lower than 8 μg/ml. The KgB test allowed for the detection of immune complexes in sera from patients with systemic lupus erythematosus, rheumatoid arthritis, idiopathic vasculitis, leprosy and leukemia. These sera were also tested using the 125 I-labelled Clq-binding activity (BA) test and the KgB test simultaneously, and a significant rank order correlation was observed. In patients with leukemia, a significant correlation was observed using three tests, KgB, 125 I-labelled Clq BA and Raji-cell radioimmunoassay (RIA). Therefore, the KgB test appears as a simple and reproducible method, utilizing a very stable reagent, with a sensitivity and specificity comparable to the other tests studied and allowing for clinical application. (author)

  8. Evaluation of an egg yolk enzyme-linked immunosorbent assay antibody test and its use to assess the prevalence of Mycoplasma gallisepticum infection in laying hens in Italy

    Directory of Open Access Journals (Sweden)

    Marco Tamba

    2010-01-01

    Full Text Available The prevalence of Mycoplasma gallisepticum infection in commercial layers was established by the presence of antibodies in eggs. Saline-extracted yolks were used with a commercial enzyme-linked immunosorbent assay kit. For the prevalence study, yolks from 30 eggs were obtained from each of 66 flocks coming from 36 layer farms. The prevalence of egg antibodies to Mycoplasma gallisepticum was 33.3% in single-age farms and 77.8% in multi-age farms. In 27 flocks, antibody titers were compared with results obtained from blood samples taken in the same flock and in the same period and analyzed with the same kit. This study has confirmed that egg yolk enzyme-linked immunosorbent assay antibody test is a suitable and practical approach for assessing the flock prevalence of Mycoplasma gallisepticum infection in layer hens.

  9. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Directory of Open Access Journals (Sweden)

    Yanil R Parma

    2012-06-01

    Full Text Available Enterohemorrhagic Escherichia coli (EHEC, a subset of Shiga toxin producing E. coli (STEC is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic uremic syndrome (HUS. Regardless of serotype, Shiga toxins (Stx1 and/or Stx2 are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx was developed using anti-Stx2 B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933 and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 400 ng /ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for 2 strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli.

  10. Antibody-mediated Prevention of Fusarium Mycotoxins in the Field

    Directory of Open Access Journals (Sweden)

    Yu-Cai Liao

    2008-10-01

    Full Text Available Fusarium mycotoxins directly accumulated in grains during the infection of wheat and other cereal crops by Fusarium head blight (FHB pathogens are detrimental to humans and domesticated animals. Prevention of the mycotoxins via the development of FHB-resistant varieties has been a challenge due to the scarcity of natural resistance against FHB pathogens. Various antibodies specific to Fusarium fungi and mycotoxins are widely used in immunoassays and antibody-mediated resistance in planta against Fusarium pathogens has been demonstrated. Antibodies fused to antifungal proteins have been shown to confer a very significantly enhanced Fusarium resistance in transgenic plants. Thus, antibody fusions hold great promise as an effective tool for the prevention of mycotoxin contaminations in cereal grains. This review highlights the utilization of protective antibodies derived from phage display to increase endogenous resistance of wheat to FHB pathogens and consequently to reduce mycotoxins in field. The role played by Fusarium-specific antibody in the resistance is also discussed.

  11. A Highly Sensitive Porous Silicon (P-Si)-Based Human Kallikrein 2 (hK2) Immunoassay Platform toward Accurate Diagnosis of Prostate Cancer.

    Science.gov (United States)

    Lee, Sang Wook; Hosokawa, Kazuo; Kim, Soyoun; Jeong, Ok Chan; Lilja, Hans; Laurell, Thomas; Maeda, Mizuo

    2015-05-22

    Levels of total human kallikrein 2 (hK2), a protein involved the pathology of prostate cancer (PCa), could be used as a biomarker to aid in the diagnosis of this disease. In this study, we report on a porous silicon antibody immunoassay platform for the detection of serum levels of total hK2. The surface of porous silicon has a 3-dimensional macro- and nanoporous structure, which offers a large binding capacity for capturing probe molecules. The tailored pore size of the porous silicon also allows efficient immobilization of antibodies by surface adsorption, and does not require chemical immobilization. Monoclonal hK2 capture antibody (6B7) was dispensed onto P-Si chip using a piezoelectric dispenser. In total 13 × 13 arrays (169 spots) were spotted on the chip with its single spot volume of 300 pL. For an optimization of capture antibody condition, we firstly performed an immunoassay of the P-Si microarray under a titration series of hK2 in pure buffer (PBS) at three different antibody densities (75, 100 and 145 µg/mL). The best performance of the microarray platform was seen at 100 µg/mL of the capture antibody concentration (LOD was 100 fg/mL). The platform then was subsequently evaluated for a titration series of serum-spiked hK2 samples. The developed platform utilizes only 15 µL of serum per test and the total assay time is about 3 h, including immobilization of the capture antibody. The detection limit of the hK2 assay was 100 fg/mL in PBS buffer and 1 pg/mL in serum with a dynamic range of 106 (10(-4) to 10(2) ng/mL).

  12. Color encoded microbeads-based flow cytometric immunoassay for polycyclic aromatic hydrocarbons in food

    International Nuclear Information System (INIS)

    Meimaridou, Anastasia; Haasnoot, Willem; Noteboom, Linda; Mintzas, Dimitrios; Pulkrabova, Jana; Hajslova, Jana; Nielen, Michel W.F.

    2010-01-01

    Food contamination caused by chemical hazards such as persistent organic pollutants (POPs) is a worldwide public health concern and requires continuous monitoring. The chromatography-based analysis methods for POPs are accurate and quite sensitive but they are time-consuming, laborious and expensive. Thus, there is a need for validated simplified screening tools, which are inexpensive, rapid, have automation potential and can detect multiple POPs simultaneously. In this study we developed a flow cytometry-based immunoassay (FCIA) using a color-encoded microbeads technology to detect benzo[a]pyrene (BaP) and other polycyclic aromatic hydrocarbons (PAHs) in buffer and food extracts as a starting point for the future development of rapid multiplex assays including other POPs in food, such as polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs). A highly sensitive assay for BaP was obtained with an IC 50 of 0.3 μg L -1 using a monoclonal antibody (Mab22F12) against BaP, similar to the IC 50 of a previously described enzyme-linked immunosorbent assay (ELISA) using the same Mab. Moreover, the FCIA was 8 times more sensitive for BaP compared to a surface plasmon resonance (SPR)-based biosensor immunoassay (BIA) using the same reagents. The selectivity of the FCIAs was tested, with two Mabs against BaP for 25 other PAHs, including two hydroxyl PAH metabolites. Apart from BaP, the FCIAs can detect PAHs such as indenol[1,2,3-cd]pyrene (IP), benz[a]anthracene (BaA), and chrysene (CHR) which are also appointed by the European Food Safety Authority (EFSA) as suitable indicators of PAH contamination in food. The FCIAs results were in agreement with those obtained with gas chromatography-mass spectrometry (GC-MS) for the detection of PAHs in real food samples of smoked carp and wheat flour and has great potential for the future routine application of this assay in a simplex or multiplex format in combination with simplified extraction procedure which are

  13. Detection of alpha-fetoprotein in magnetic immunoassay of thin channels using biofunctional nanoparticles

    Science.gov (United States)

    Tsai, H. Y.; Gao, B. Z.; Yang, S. F.; Li, C. S.; Fuh, C. Bor

    2014-01-01

    This paper presents the use of fluorescent biofunctional nanoparticles (10-30 nm) to detect alpha-fetoprotein (AFP) in a thin-channel magnetic immunoassay. We used an AFP model biomarker and s-shaped deposition zones to test the proposed detection method. The results show that the detection using fluorescent biofunctional nanoparticle has a higher throughput than that of functional microparticle used in previous experiments on affinity reactions. The proposed method takes about 3 min (versus 150 min of previous method) to detect 100 samples. The proposed method is useful for screening biomarkers in clinical applications, and can reduce the run time for sandwich immunoassays to less than 20 min. The detection limits (0.06 pg/ml) and linear ranges (0.068 pg/ml-0.68 ng/ml) of AFP using fluorescent biofunctional nanoparticles are the same as those of using functional microparticles within experimental errors. This detection limit is substantially lower and the linear range is considerably wider than those of enzyme-linked immunosorbent assay (ELISA) and other methods in sandwich immunoassay methods. The differences between this method and an ELISA in AFP measurements of serum samples were less than 12 %. The proposed method provides simple, fast, and sensitive detection with a high throughput for biomarkers.

  14. A comparative clinical study of efficacy of microimmuno assay with WIDAL-test in enteric fever in children

    Directory of Open Access Journals (Sweden)

    Gandarajapura Nagaraj Madhu

    2014-01-01

    Full Text Available The diagnosis of typhoid fever in young children is also a dilemma because of its manifestations and typical presentation may not be seen in all cases. Antibodies to Salmonella typhi antigen are developed in the human body, which can be detected as a diagnostic test for the enteric fever. Objective: This study was undertaken to compare the efficacy of WIDAL-test with micro-immunoassay (dot enzyme immunosorbent assay. Method: 40 cases of clinically suspected enteric fever cases were included in this study. Result: In the present study, nearly 92% were positive for micro immunoassay (dot-enzyme immunosorbent assay by Enterocheck-WB kit, 80% were positive for WIDAL and only 15% were culture positive. Immunoassay positive, but WIDAL negative cases were 20%, whereas WIDAL positive and immunoassay negative cases were only 7.5%. The positive predictivity of micro-immunoassay in diagnosing enteric fever is better than WIDAL both in 1st and 2nd week of illness. Micro-immunoassay done in the study was rapid in diagnosing the case. Conclusion: It is concluded from the present study that the micro-immunoassay (Enterocheck-WB is better than WIDAL-test in the diagnosis of enteric fever in children.

  15. Detection of antibodies to Actinobacillus pleuropneumoniae serotype 12 in pig serum using a blocking enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Andresen, Lars Ole; Klausen, Joan; Barfod, Kristen

    2002-01-01

    and from herds declared free of infection with Ap. The Ap serotype 12 blocking ELISA showed a herd sensitivity of 0.77 (95% confidence interval, 0.62-0.88) and a herd specificity of 1.00 (0.95-1.00) with a cut-off value at 40% relative absorbance or 60% inhibition. The assay may be used advantageously......The objective was to develop a blocking enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to Actinobacillus pleuropneumoniae (Ap) serotype 12 in pig serum. Lipopolysaccharide (LPS) from Ap serotype 12 was purified and used as antigen in the assay. Antibodies to the LPS antigen...... in samples of pig serum were detected by inhibition of the binding of polyclonal rabbit antibodies raised against Ap serotype 12. The assay was evaluated against sera from experimentally infected pigs, from pig herds naturally infected with Ap and from herds declared free of Ap serotypc 12 infection...

  16. Associations of Neospora caninum seropositivity with gestation number and pregnancy outcome in Danish dairy herds

    DEFF Research Database (Denmark)

    Jensen, Anette Møllegaard; Bjorkman, C.; Kjeldsen, A.M.

    1999-01-01

    The prevalence and distribution of seropositivity towards the protozoan parasite Neospora caninum were studied in single blood samples from 1561 cows from 31 Danish dairy herds. Blood samples were analysed by an indirect enzyme-linked immunoassay and an indirect fluorescent-antibody test, Seropre......The prevalence and distribution of seropositivity towards the protozoan parasite Neospora caninum were studied in single blood samples from 1561 cows from 31 Danish dairy herds. Blood samples were analysed by an indirect enzyme-linked immunoassay and an indirect fluorescent-antibody test......, Seroprevalence in 15 herds with previous abortions assigned to neosporosis ranged from I% to 58%, with a mean frequency of 22%. In eight out of 16 herds without a history of N. caninum related abortions, no seroreactors were found. In the remaining eight herds, the seroprevalence ranged from 6% to 59...

  17. Interference by antiruthenium antibodies in the Roche thyroid-stimulating hormone assay

    NARCIS (Netherlands)

    Buijs, M. M.; Gorgels, J. P. M. C.; Endert, E.

    2011-01-01

    There are many causes of interference in immunoassays causing erratic patient results. A method-specific interference due to antiruthenium antibodies in Roche free thyroxine (fT4) and free triiodothyronine (fT3) assays has been described previously. As a result, a new generation fT4 assay has been

  18. Catalytic Antibodies

    Indian Academy of Sciences (India)

    biological processes and is intended to catalyze a reaction for which no real enzyme is ... the reaction. In order to enhance the rates of chemical reactions, enzymes, ..... of such antibodies has already been exploited in the production of a biosensor. ..... tant to the pharmaceutical and fine chemical industries for the synthesis ...

  19. Magnetic nanoparticle based purification and enzyme-linked immunosorbent assay using monoclonal antibody against enrofloxacin

    Science.gov (United States)

    Kim, Nam-Gun; Kim, Myeong-Ae; Park, Young-Il; Jung, Tae-Sung; Son, Seong-Wan; So, ByungJae

    2015-01-01

    Monoclonal anti-enrofloxacin antibody was prepared for a direct competitive enzyme-linked immunosorbent assay (ELISA) and purification system using monoclonal antibody (mAb) coupled magnetic nanoparticles (MNPs). The IC50 values of the developed mAb for enrofloxacin (ENR), ciprofloxacin, difloxacin, sarafloxacin, pefloxacin, and norfloxacin were 5.0, 8.3, 9.7, 21.7, 36.0, and 63.7 ng/mL, respectively. The lowest detectable level of ENR was 0.7 ng/mL in the prepared ELISA system. To validate the developed ELISA in the food matrix, known amounts of ENR were spiked in meat and egg samples at 10, 20 and 30 ng/mL. Recoveries for ENR ranged from 72.9 to 113.16% with a coefficient of variation (CV) of 2.42 to 10.11%. The applicability of the mAb-MNP system was verified by testing the recoveries for ENR residue in three different matrices. Recoveries for ENR ranged from 75.16 to 86.36%, while the CV ranged from 5.08 to 11.53%. Overall, ENR-specific monoclonal antibody was prepared and developed for use in competitive to ELISAs for the detection of ENR in animal meat samples. Furthermore, we suggest that a purification system for ENR using mAb-coupled MNPs could be useful for determination of ENR residue in food. PMID:26040610

  20. Ethylbenzene induces microsomal oxygen free radical generation: antibody-directed characterization of the responsible cytochrome P450 enzymes.

    Science.gov (United States)

    Serron, S C; Dwivedi, N; Backes, W L

    2000-05-01

    Small aromatic hydrocarbons cause changes in oxidative metabolism by modulating the levels of cytochrome P450 enzymes, with the changes in these enzymes being responsible for qualitative changes in aromatic hydrocarbon metabolism. The goal of this study was to determine if exposure to the small alkylbenzene ethylbenzene (EB) leads to an increase in hepatic free radical production. Male F344 rats were treated with ip injections of EB (10 mmol/kg) and compared to corn oil controls. Hepatic free radical production was examined by measuring the conversion of 2',7'-dichlorofluorescin diacetate (DCFH-DA) to its fluorescent product 2',7'-dichlorofluorescein (DCF). A significant elevation of fluorescent DCF production was observed after treatment with EB, despite the lack of effect on overall cytochrome P450 levels. This process was shown to be inhibitable by metyrapone, an inhibitor of P450. DCF production was also inhibited by catalase, suggesting that hydrogen peroxide (H(2)O(2)) is one of the reactive oxygen intermediates involved in EB-mediated reactive oxygen species (ROS) formation. Interestingly, superoxide dismutase (SOD) did not inhibit DCF production in corn oil-treated rats but was an effective inhibitor in the EB-treated groups. In an effort to determine if the increase in ROS production was related to changes in specific P450 enzymes, DCF production was measured in the presence of anti-CYP2B, anti-CYP2C11, anti-CYP2E1, and anti-CYP3A2 inhibitory antibodies. Anti-CYP2B antibodies inhibited DCF production in EB-treated, but not corn oil groups, which is consistent with the low constitutive levels of this enzyme and its induction by EB. The data also demonstrate that CYP2B contributes to ROS production. Anti-CYP2C11 did not influence DCF production in either group. ROS formation in corn oil-treated rats as well as in ethylbenzene-treated rats was also inhibited with antibodies to anti-CYP2E1 and anti-CYP3A2. These results suggest that CYP2C11 does not appear to

  1. Tuberculin purified protein derivative (PPD) immunoassay as an in vitro alternative assay for identity and confirmation of potency.

    Science.gov (United States)

    Ho, Mei M; Kairo, Satnam K; Corbel, Michael J

    2006-01-01

    Tuberculin purified protein derivative (PPD) currently can only be standardised by delayed hypersensitivity skin reactions in sensitised guinea pigs. An in vitro dot blot immunoassay was developed for both identity and confirmation of potency estimation of PPD. Polyclonal antibodies (mainly IgG) were generated and immunoreacted with human, bovine and, to lesser extent, avian PPD preparations. Combining size exclusion chromatography (FPLC-SEC) and dot blot immunoassay, the results showed that PPD preparations were mixtures of very heterogeneous tuberculoproteins ranging in size from very large aggregates to very small degraded molecules. All individual fractions of PPD separated by size were immunoreactive, although those of the largest molecular sizes appeared the most immunoreactive in this in vitro dot blot immunoassay. This method is very sensitive and specific to tuberculoproteins and can be an in vitro alternative for the in vivo intradermal skin assay which uses guinea pigs for identity of PPD preparations. Although the capacity of PPD to elicit cell-mediated immune responses on intradermal testing has to be confirmed by in vivo assay, the dot blot immunoassay offers a rapid, sensitive and animal-free alternative to in vivo testing for confirming the identity of PPD preparations with appropriate potencies. This alternative assay would be particularly useful for national regulatory laboratories for confirming the data of manufacturers and thus reducing the use of animals.

  2. Hydrogel nanoparticle based immunoassay

    Science.gov (United States)

    Liotta, Lance A; Luchini, Alessandra; Petricoin, Emanuel F; Espina, Virginia

    2015-04-21

    An immunoassay device incorporating porous polymeric capture nanoparticles within either the sample collection vessel or pre-impregnated into a porous substratum within fluid flow path of the analytical device is presented. This incorporation of capture particles within the immunoassay device improves sensitivity while removing the requirement for pre-processing of samples prior to loading the immunoassay device. A preferred embodiment is coreshell bait containing capture nanoparticles which perform three functions in one step, in solution: a) molecular size sieving, b) target analyte sequestration and concentration, and c) protection from degradation. The polymeric matrix of the capture particles may be made of co-polymeric materials having a structural monomer and an affinity monomer, the affinity monomer having properties that attract the analyte to the capture particle. This device is useful for point of care diagnostic assays for biomedical applications and as field deployable assays for environmental, pathogen and chemical or biological threat identification.

  3. Comparison of enzyme-linked immunosorbent assay, radioimmunoassay, complement fixation, anticomplement immunofluorescence and passive haemaglutination techniques for detecting cytomegalovirus IgG antibody

    Energy Technology Data Exchange (ETDEWEB)

    Booth, J C; Hannington, G; Bakir, T M.F.; Stern, H; Kangro, H; Griffiths, P D; Heath, R B [Saint George' s Hospital Medical School, London (UK); Saint Bartholomew' s Hospital, London (UK))

    1982-12-01

    The radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) techniques were found to be comparable in sensitivity and specificity for detecting cytomegalovirus IgG antibody, and 10 to 100 times more sensitive than complement-fixation (CF), anticomplement immunofluorescence (ACIF) and passive haemagglutination (PHA). In screening tests for antibody, the frequency of false-positive and -negative results was 0.6% for RIA and ELISA, 1.5% for CF, 1.6% for ACIF and 3.6% for PHA. PHA was the least satisfactory test, largely because of technical problems.

  4. Evaluation of enzyme-linked immunosorbent assays based on monoclonal antibodies for the serology and antigen detection in canine parvovirus infections.

    NARCIS (Netherlands)

    G.F. Rimmelzwaan (Guus); N. Juntti; B. Klingeborn; J. Groen (Jan); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1990-01-01

    textabstractAn enzyme-linked immunosorbent assay (ELISA) system was developed for the detection of canine parvovirus (CPV) or CPV antigen in dog faeces and two other ELISA systems were developed for the detection of CPV-specific antibodies in dog sera. The ELISA's were based on the use of

  5. Galactomannan enzyme immunoassay and quantitative Real Time PCR as tools to evaluate the exposure and response in a rat model of aspergillosis after posaconazole prophylaxis.

    Science.gov (United States)

    Cendejas-Bueno, Emilio; Forastiero, Agustina; Ruiz, Isabel; Mellado, Emilia; Buitrago, María José; Gavaldà, Joan; Gomez-Lopez, Alicia

    2016-11-01

    A steroid-immunosuppressed rat model of invasive pulmonary aspergillosis was use to examine the usefulness of galactomannan enzyme immunoassay (GM) and quantitative real time PCR (RT-PCR) in evaluating the association between response and exposure after a high dose of prophylactic posaconazole. Two different strains of Aspergillus fumigatus with different in vitro posaconazole susceptibility were used. Serum concentrations demonstrated similar posaconazole exposure for all treated animals. However, response to posaconazole relied on the in vitro susceptibility of the infecting strain. After prophylaxis, galactomannan index and fungal burden only decreased in those animals infected with the most susceptible strain. This study demonstrated that both biomarkers may be useful tools for predicting efficacy of antifungal compounds in prophylaxis. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  6. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, L; Smid, B; Valicek, L; Jurak, E [Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia)

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples using ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC.

  7. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    International Nuclear Information System (INIS)

    Rodak, L.; Smid, B.; Valicek, L.; Jurak, E.

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples usiOg ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC. (B.S.)

  8. The production of antibodies for radioimmunoassay

    International Nuclear Information System (INIS)

    Court, G.

    1975-01-01

    Three factors which affect the outcome of any immunisation schedule designed to produce antisera for radio-immunoassay, the antigen, the method of immunisation and the choice of animal are considered. Several factors concerning the nature of the antigen are dealt with, for example, the molecular size and immunogenicity of the antigen. It is noted that the larger polypeptide and proteins are sufficiently immunogenic to elicit a useful antibody response alone and that whilst substances with molecular weights of less than 2000 may produce a response alone they will probably produce a better one if they are conjugated (chemically coupled) to a much larger molecule. The method of immunisation is discussed including a consideration of the use of adjuvant and the route and timing of injections. It is noted that antisera showing the relevant properties for radio-immunoassay are rarely produced without emulsification of the immunogen in Freund's adjuvant although this is not an absolute requirement for antibody production. Data are presented comparing the intramuscular and multiple intradermal routes of injection. The results, however, fail to demonstrate any major advantage for either method although the latter may be more economical, producing high titre antisera with relatively small amounts of immunogen. Because of their convenience rabbits are generally the first choice of animal for raising antisera for radioimmunoassay although guinea pigs, chickens and sheep have been used successfully in many cases

  9. Aspergillus Galactomannan Enzyme Immunoassay and Quantitative PCR for Diagnosis of Invasive Aspergillosis with Bronchoalveolar Lavage Fluid

    Science.gov (United States)

    Musher, Benjamin; Fredricks, David; Leisenring, Wendy; Balajee, S. Arunmozhi; Smith, Caitlin; Marr, Kieren A.

    2004-01-01

    Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in hematopoietic stem cell transplant patients. Diagnosis requires microbiological or histopathologic demonstration of the organism in tissues; however, cultivation of Aspergillus species from respiratory secretions has low diagnostic sensitivity. Assays to detect Aspergillus antigen or DNA in bronchoalveolar lavage (BAL) fluid could facilitate earlier diagnosis, thereby guiding optimal therapy and obviating the need for additional costly and potentially morbid diagnostic evaluation. We evaluated the performance of a galactomannan enzyme immunoassay (GM EIA; Bio-Rad) by using a range of index cutoffs to define positivity and a quantitative PCR (qPCR) assay for the detection of Aspergillus species from BAL samples of patients with proven and probable IPA (case patients; n = 49) and without IPA (control patients; n = 50). The sensitivity of the GM EIA was 61% with an index cutoff of 1.0 and 76% with an index cutoff of 0.5; the corresponding specificities were 98 and 94%, respectively. The sensitivity and specificity of qPCR assay were 67 and 100%, respectively. The sensitivity with 22 culture-negative BAL specimens from patients with IPA was 41% for GM EIA with an index cutoff of 1.0, 59% for GM EIA with an index cutoff of 0.5, and 36% for qPCR assay. GM EIA indices and DNA quantities corresponded to BAL fungal burdens, with culture-positive samples having larger amounts of antigen and DNA compared to culture-negative samples. GM EIA and qPCR assay add to the sensitivity of BAL for diagnosing IPA in high-risk patients, with excellent specificity. Adjunctive use of these tests may reduce dependence on invasive diagnostic procedures. PMID:15583275

  10. Evaluation of Correlation between Pretest Probability for Clostridium difficile Infection and Clostridium difficile Enzyme Immunoassay Results.

    Science.gov (United States)

    Kwon, Jennie H; Reske, Kimberly A; Hink, Tiffany; Burnham, C A; Dubberke, Erik R

    2017-02-01

    The objective of this study was to evaluate the clinical characteristics and outcomes of hospitalized patients tested for Clostridium difficile and determine the correlation between pretest probability for C. difficile infection (CDI) and assay results. Patients with testing ordered for C. difficile were enrolled and assigned a high, medium, or low pretest probability of CDI based on clinical evaluation, laboratory, and imaging results. Stool was tested for C. difficile by toxin enzyme immunoassay (EIA) and toxigenic culture (TC). Chi-square analyses and the log rank test were utilized. Among the 111 patients enrolled, stool samples from nine were TC positive and four were EIA positive. Sixty-one (55%) patients had clinically significant diarrhea, 19 (17%) patients did not, and clinically significant diarrhea could not be determined for 31 (28%) patients. Seventy-two (65%) patients were assessed as having a low pretest probability of having CDI, 34 (31%) as having a medium probability, and 5 (5%) as having a high probability. None of the patients with low pretest probabilities had a positive EIA, but four were TC positive. None of the seven patients with a positive TC but a negative index EIA developed CDI within 30 days after the index test or died within 90 days after the index toxin EIA date. Pretest probability for CDI should be considered prior to ordering C. difficile testing and must be taken into account when interpreting test results. CDI is a clinical diagnosis supported by laboratory data, and the detection of toxigenic C. difficile in stool does not necessarily confirm the diagnosis of CDI. Copyright © 2017 American Society for Microbiology.

  11. Horseradish peroxidase-loaded nanospheres attached to hollow gold nanoparticles as signal enhancers in an ultrasensitive immunoassay for alpha-fetoprotein

    International Nuclear Information System (INIS)

    Li, Ya; Yuan, Ruo; Chai, Yaqin; Zhuo, Ying; Su, Huilan; Zhang, Yuxia

    2014-01-01

    We report on a novel electrochemical signal amplification strategy for use in immunoassays. The highly responsive immunoelectrode was constructed in the following way: (1) The surface of a gold electrode was covered with a layer single-walled carbon nanotubes dispersed in chitosane functionalized with L-cysteine; (2) Gold nanoparticles containing protein A and anti-alpha-fetoprotein (anti-AFP) were then covalently attached to the surface via the thiol groups of the chitosane. The electrode is then exposed to the analyte (AFP) which then is bound by the antibody. In the next step, a gold-conjugated secondary antibody is added that was prepared in the following way: (1) Horseradish peroxidase was crosslinked and the resulting spheres were coated with hollow gold nanoparticles (hollow Au-NPs) to give nanospheres of ∼100 nm in diameter. (2) These were the coated with thionine and, in a last step, with secondary antibody. The use of these materials has several attractive features: The HRP-NPs functionalized with hollow Au-NPs possess a large surface area that can load the large amount of secondary antibody. Thionine (Thi) is highly redox active and improves the intensity of the signal. Carbon nanotubes were used because they possess an excellent electron transfer rate and large surface area. Following incubation of the modified electrode (a) with a sample containing AFP, (b) then with the secondary antibody, and (c) with washing buffer, the electrode is placed in a solution containing H 2 O 2 . The HRP in the smart secondary antibody causes the catalytic decomposition of H 2 O 2 and the results in an electrical current that is linearly related to the concentration of AFP in the 0.025 to 5.0 ng mL −1 concentration range. The detection limit for AFP is as low as 8.3 pg mL −1 . We believe that this novel kind of immunoassay represents a promising tool for use in sensitive clinical assays. (author)

  12. Microsphere-based immunoassay integrated with a microfluidic network to perform logic operations

    International Nuclear Information System (INIS)

    Sabhachandani, Pooja; Cohen, Noa; Sarkar, Saheli; Konry, Tania

    2015-01-01

    Lab on a chip (LOC) intelligent diagnostics can be described by molecular logic-based circuits. We report on the development of an LOC approach with logic capability for screening combinations of antigen and antibody in the same sample. A microsphere-based immunoassay was integrated with a microfluidic network device to perform the logic operations AND and INHIBIT. Using the clinically relevant biomarkers TNF-α cytokine and anti-TNF-α antibody, we obtained a fluorescent output in the presence of both inputs. This results in an AND operation, while the presence of only one specific input results in a different fluorescent signal, thereby indicating the INHIBIT operation. This approach demonstrates the effective use of molecular logic computation for developing portable, point-of-care technologies for diagnostic purposes due to fast detection times, minimal reagent consumption and low costs. This model system may be further expanded to screening of multiple disease markers, combinatorial logic applications, and developing “smart” sensors and therapeutic technologies. (author)

  13. Composite poly(methyl methacrylate-methacrylic acid-2-hydroxyethyl methacrylate) latex for immunoassay. The case of plasminogen.

    Science.gov (United States)

    Miksa, B; Wilczynska, M; Cierniewski, C; Basinska, T; Slomkowski, S

    1995-01-01

    Poly(methyl methacrylate-methacrylic acid-2-hydroxyethyl methacrylate) latex (ACRYLAT) was synthesized by radical precipitation polymerization. The mass median diameter (MMD) and the geometrical standard deviation (GSD) of the ACRYLAT particles were 138 nm and 1.2, respectively. The concentration of the titrable carboxylic groups in the surface layer of latex particles was equal to 8.41 x 10(-6) mol m-2. Latex was able to bind up to 2.82 x 10(-7) mol of 1-aminopyrene per 1 m2 of the surface of the latex particles due to the ionic interactions between carboxylate anions and ammonium cations of protonated 1-aminopyrene. ACRYLAT was able to immobilize covalently human serum albumin in amounts up to 0.23 mg m-2. Aggregation of ACRYLAT with immobilized HSA, induced with specific antibodies (anti-HSA), was investigated turbidimetrically. The results indicated that in the model turbidimetric immunoassay, ACRYLAT coated with HSA can be used for the detection of anti-HSA in the goat anti-HSA serum diluted from 50 to 7000-fold. Immobilization of rabbit antibodies to plasminogen (anti-Plg) to ACRYLAT via the epsilon-aminocaproic acid linkers provided particles which were used for the development of the turbidimetric immunoassay for plasminogen. In this assay plasminogen could be detected in concentration ranging from 0.75 to 75 micrograms ml-1 in the blood plasma.

  14. Development of improved enzyme-based and lateral flow immunoassays for rapid and accurate serodiagnosis of canine brucellosis.

    Science.gov (United States)

    Cortina, María E; Novak, Analía; Melli, Luciano J; Elena, Sebastián; Corbera, Natalia; Romero, Juan E; Nicola, Ana M; Ugalde, Juan E; Comerci, Diego J; Ciocchini, Andrés E

    2017-09-01

    Brucellosis is a widespread zoonotic disease caused by Brucella spp. Brucella canis is the etiological agent of canine brucellosis, a disease that can lead to sterility in bitches and dogs causing important economic losses in breeding kennels. Early and accurate diagnosis of canine brucellosis is central to control the disease and lower the risk of transmission to humans. Here, we develop and validate enzyme and lateral flow immunoassays for improved serodiagnosis of canine brucellosis using as antigen the B. canis rough lipopolysaccharide (rLPS). The method used to obtain the rLPS allowed us to produce more homogeneous batches of the antigen that facilitated the standardization of the assays. To validate the assays, 284 serum samples obtained from naturally infected dogs and healthy animals were analyzed. For the B. canis-iELISA and B. canis-LFIA the diagnostic sensitivity was of 98.6%, and the specificity 99.5% and 100%, respectively. We propose the implementation of the B. canis-LFIA as a screening test in combination with the highly accurate laboratory g-iELISA. The B. canis-LFIA is a rapid, accurate and easy to use test, characteristics that make it ideal for the serological surveillance of canine brucellosis in the field or veterinary laboratories. Finally, a blind study including 1040 serum samples obtained from urban dogs showed a prevalence higher than 5% highlighting the need of new diagnostic tools for a more effective control of the disease in dogs and therefore to reduce the risk of transmission of this zoonotic pathogen to humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Treatment with belimumab in systemic lupus erythematosus does not impair antibody response to 13-valent pneumococcal conjugate vaccine.

    Science.gov (United States)

    Nagel, J; Saxne, T; Geborek, P; Bengtsson, A A; Jacobsen, S; Svaerke Joergensen, C; Nilsson, J-Å; Skattum, L; Jönsen, A; Kapetanovic, M C

    2017-09-01

    Background/purpose The objective of this study was to explore the impact of systemic lupus erythematosus and belimumab given in addition to standard of care therapy on 13-valent conjugated pneumococcal vaccine (PCV13) response. Methods Forty-seven systemic lupus erythematosus patients and 21 healthy controls were immunized with a single dose of 13-valent conjugated pneumococcal vaccine. Forty systemic lupus erythematosus patients were treated with traditional disease-modifying anti rheumatic drugs, 11 of those received belimumab in addition, and 32 patients were treated with concomitant prednisolone. Quantification of serotype specific IgG levels to 12 pneumococcal capsular polysaccharides was performed in serum taken before and four to six weeks after vaccination using multiplex fluorescent microsphere immunoassay. IgG levels against serotypes 23F and 6B were also analyzed using standard enzyme-linked immunosorbent assays. Opsonophagocytic assay was performed on serotype 23F to evaluate the functionality of the antibodies. Pre- and post-vaccination log transformed antibody levels were compared to determine the impact of systemic lupus erythematosus diagnosis and different treatments on antibody response. Results Systemic lupus erythematosus patients as a group showed lower post-vaccination antibody levels and lower fold increase of antibody levels after vaccination compared to controls ( p = 0.02 and p = 0.009, respectively). Systemic lupus erythematosus patients treated with belimumab in addition to standard of care therapy or with only hydroxychloroquine did not differ compared to controls, whereas the other treatment groups had significantly lower fold increase of post-vaccination antibody levels. Higher age was associated with lower post-vaccination antibody levels among systemic lupus erythematosus patients. Conclusion Belimumab given in addition to traditional disease-modifying anti rheumatic drugs or prednisolone did not further impair antibody

  16. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  17. COMPARISON OF IMMUNOASSAY AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY METHODS FOR MEASURING 3,5,6-TRICHLORO-2PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    Science.gov (United States)

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by a commercial RaPID immunoassay testing kit. ...

  18. Generation of monoclonal antibodies against peptidylarginine deiminase 2 (PAD2) and development of a PAD2-specific enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Damgaard, Dres; Palarasah, Yaseelan; Skjødt, Karsten

    2014-01-01

    The enzyme peptidylarginine deiminase 2 (PAD2) has been associated with inflammatory diseases, such as rheumatoid arthritis and neurodegenerative diseases including multiple sclerosis. To investigate the association of various diseases with extracellular PAD2, we raised monoclonal antibodies (m......Abs) against rabbit PAD2 and evaluated their cross-reactivity with human PAD2 by indirect enzyme-linked immunosorbent assay (ELISA), western blotting and immunohistological staining of inflamed synovial tissue. Moreover, we established a sandwich ELISA detecting human PAD2, based on two different monoclonal...... diseases....

  19. False-negative type-specific glycoprotein G antibody responses in STI clinic patients with recurrent HSV-1 or HSV-2 DNA positive genital herpes, The Netherlands.

    Science.gov (United States)

    van Rooijen, Martijn S; Roest, Wim; Hansen, Gino; Kwa, David; de Vries, Henry J C

    2016-06-01

    Herpes simplex virus (HSV) type-discriminating antibody tests (glycoprotein G (gG) directed) are used to identify naïve persons and differentiate acute infections from recurrences. We studied test characteristics of three commercially available antibody tests in patients with recurrent (established by viral PCR tests) herpes simplex virus type 1 (HSV-1) or herpes simplex virus type 2 (HSV-2) genital herpes episodes. Serum samples (at minimum 3 months after t=0) were examined for the presence of gG-1-specific or gG-2-specific antibodies using the HerpeSelect 1 and 2 Immunoblot IgG, the HerpeSelect 1 and 2 enzyme linked immunoassays IgG and the LIAISON HSV-1 and HSV-2 IgG indirect chemiluminescence immunoassays. The immunoblot was HSV-1 positive in 70.6% (95% CI 44.0% to 89.7%), the LIAISON in 88.2% (95% CI 63.5% to 98.5%) and the ELISA in 82.4% (95% CI 56.6% to 96.2%) of the 17 patients with a recurrent HSV-1 episode. From 33 patients with a recurrent HSV-2 episode, the immunoblot was HSV-2 positive in 84.8% (95% CI 68.1% to 94.9%), the LIAISON in 69.7% (95% CI 51.3% to 84.4%) and the ELISA in 84.8% (95% CI 68.1% to 94.9%). Among 15/17 (88.2%; 95% CI 63.5% to 98.5%) patients with HSV-1 and 30/33 (90.1%; 95% CI 75.7% to 98.1%) patients with HSV-2, HSV-1 or HSV-2 antibodies, respectively, were detected in at least one of the three antibody tests. Commercial type-specific gG HSV-1 or HSV-2 antibody assays were false negative in 12-30% of patients with recurrent HSV-1 or HSV-2 DNA positive genital lesions. The clinical and epidemiological use of type-specific HSV serology can be hampered by false-negative results, especially if based on a single test. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Multiplex dipstick immunoassay for semi-quantitative determination of Fusarium mycotoxins in cereals

    Energy Technology Data Exchange (ETDEWEB)

    Lattanzio, Veronica M.T., E-mail: veronica.lattanzio@ispa.cnr.it [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy); Nivarlet, Noan [UNISENSOR S.A., Zoning industriel du Dossay, Rue du Dossay no 3, B-4020 Liege (Belgium); Lippolis, Vincenzo; Gatta, Stefania Della [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy); Huet, Anne-Catherine; Delahaut, Philippe [Centre d' Economie Rurale (CER Groupe), Rue du Point du Jour no 8, B-6900 Marloie (Belgium); Granier, Benoit [UNISENSOR S.A., Zoning industriel du Dossay, Rue du Dossay no 3, B-4020 Liege (Belgium); Visconti, Angelo [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy)

    2012-03-09

    Highlights: Black-Right-Pointing-Pointer We developed a rapid method based on a multiplex dipstick immunoassay. Black-Right-Pointing-Pointer The assay allowed the determination of major Fusarium toxins in wheat, oats, maize. Black-Right-Pointing-Pointer We obtained cut off levels close to EU regulatory levels. - Abstract: A multiplex dipstick immunoassay based method for the simultaneous determination of major Fusarium toxins, namely zearalenone, T-2 and HT-2 toxins, deoxynivalenol and fumonisins in wheat, oats and maize has been developed. The dipstick format was based on an indirect competitive approach. Four test lines (mycotoxin-BSA conjugates) and one control line were located on the strip membrane. Labelled antibodies were freeze-dried within the microwell. Two matrix-related sample preparation protocols have been developed for wheat/oats (not containing fumonisins) and maize (containing fumonisins) respectively. The use of a methanol/water mixture for sample preparation allowed recoveries in the range 73-109% for all mycotoxins in all tested cereals, with relative standard deviation less than 10%. The optimized immunoassay was able to detect target mycotoxins at cut off levels equal to 80% of EU maximum permitted levels, i.e. 280, 400, 1400 and 3200 {mu}g kg{sup -1}, respectively, for zearalenone, T-2/HT-2 toxins, deoxynivalenol and fumonisins in maize, and 80, 400 and 1400 {mu}g kg{sup -1}, respectively, for zearalenone, T-2/HT-2 toxins and deoxynivalenol in wheat and oats. Analysis of naturally contaminated samples resulted in a good agreement between multiplex dipstick and validated confirmatory LC-MS/MS. The percentage of false positive results was less than or equal to 13%, whereas no false negative results were obtained. Data on the presence/absence of 6 mycotoxins at levels close to EU regulatory levels were obtained within 30 min. The proposed immunoassay protocol is rapid, inexpensive, easy-to-use and fit for purpose of rapid screening of mycotoxins

  1. Comparative evaluation of the Ridascreen Verotoxin enzyme immunoassay for detection of Shiga-toxin producing strains of Escherichia coli (STEC) from food and other sources.

    Science.gov (United States)

    Beutin, L; Steinrück, H; Krause, G; Steege, K; Haby, S; Hultsch, G; Appel, B

    2007-03-01

    To evaluate the suitability of the commercially distributed Ridascreen Verotoxin enzyme immunoassay (EIA) for detection of known genetic types of the Vero (Shiga) toxins 1 (Stx1) and 2 (Stx2) families and to determine its relative sensitivity and specificity. The Ridascreen-EIA was compared with the Vero cell assay, a P(1)-glycoprotein receptor EIA and with stx gene-specific PCs for detection of Stx with 43 Shiga toxin-producing strains of Escherichia coli (STEC) reference strains and with 241 test strains. The Ridascreen-EIA detects strains producing Stx1 and variants Stx1c and Stx1d, as well as Stx2 and variants Stx2d1, Stx2d2, Stx2e, Stx2d, Stx2-O118 (Stx2d-ount), Stx2-NV206, Stx2f and Stx2g. The assay showed a relative sensitivity of 95.7% and a relative specificity of 98.7%. Some of the Stx2-O118-, Stx2e- and Stx2g-producing STEC were not detected with the Ridascreen-EIA probably because of low amount of toxin produced by these strains. The Ridascreen-EIA is able to detect all known types of Stx and is applicable for routine screening of bacterial isolates owing to its high specificity. It is less applicable for testing samples where low amounts of Stx are expected, such as mixed cultures and certain Stx2 variants. This study presents a first comprehensive evaluation of the Ridascreen-EIA, a rapid standardized STEC screening test for routine diagnostic laboratories. Data are presented on the type of the spectrum of Stx that are detected with this immunoassay and its advantages and limits for practical use.

  2. Alkaline phosphatase labeled SERS active sandwich immunoassay for detection of Escherichia coli

    Science.gov (United States)

    Bozkurt, Akif Goktug; Buyukgoz, Guluzar Gorkem; Soforoglu, Mehmet; Tamer, Ugur; Suludere, Zekiye; Boyaci, Ismail Hakki

    2018-04-01

    In this study, a sandwich immunoassay method utilizing enzymatic activity of alkaline phosphatase (ALP) on 5-bromo-4-chloro-3-indolyl phosphate (BCIP) for Escherichia coli (E. coli) detection was developed using surface enhanced Raman spectroscopy (SERS). For this purpose, spherical magnetic gold coated core-shell nanoparticles (MNPs-Au) and rod shape gold nanoparticles (Au-NRs) were synthesized and modified for immunomagnetic separation (IMS) of E. coli from the solution. In order to specify the developed method to ALP activity, Au-NRs were labeled with this enzyme. After successful construction of the immunoassay, BCIP substrate was added to produce the SERS-active product; 5-bromo-4-chloro-3-indole (BCI). A good linearity (R2 = 0.992) was established between the specific SERS intensity of BCI at 600 cm- 1 and logarithmic E. coli concentration in the range of 1.7 × 101-1.7 × 106 cfu mL- 1. LOD and LOQ values were also calculated and found to be 10 cfu mL- 1 and 30 cfu mL- 1, respectively.

  3. Evaluation of a rapid test for HIV antibodies in saliva and blood ...

    African Journals Online (AJOL)

    Objective. To test whole blood and saliva for HIV antibodies (anti-HIV) using a rapid test strip capillary flow . immunoassay, and to correlate the test strip results with blood specimen results obtained from routine diagnostic antiHIV assays. Design. A prospective pilot study of selected HIV-positive and HIV-negative individuals ...

  4. Cost-effectiveness of a modified two-step algorithm using a combined glutamate dehydrogenase/toxin enzyme immunoassay and real-time PCR for the diagnosis of Clostridium difficile infection.

    Science.gov (United States)

    Vasoo, Shawn; Stevens, Jane; Portillo, Lena; Barza, Ruby; Schejbal, Debra; Wu, May May; Chancey, Christina; Singh, Kamaljit

    2014-02-01

    The analytical performance and cost-effectiveness of the Wampole Toxin A/B EIA, the C. Diff. Quik Chek Complete (CdQCC) (a combined glutamate dehydrogenase antigen/toxin enzyme immunoassay), two RT-PCR assays (Progastro Cd and BD GeneOhm) and a modified two-step algorithm using the CdQCC reflexed to RT-PCR for indeterminate results were compared. The sensitivity of the Wampole Toxin A/B EIA, CdQCC (GDH antigen), BD GeneOhm and Progastro Cd RT-PCR were 85.4%, 95.8%, 100% and 93.8%, respectively. The algorithm provided rapid results for 86% of specimens and the remaining indeterminate results were resolved by RT-PCR, offering the best balance of sensitivity and cost savings per test (algorithm ∼US$13.50/test versus upfront RT-PCR ∼US$26.00/test). Copyright © 2012. Published by Elsevier B.V.

  5. Immunological methods for gentamicin determination

    International Nuclear Information System (INIS)

    Krugers Dagneauz, P.G.L.C.; Olthuis, F.M.F.G.

    1979-01-01

    For immunoassay, an antibody against the substance to the determined, the pure substance itself, and a labelled form or derivative of the substance are required. The principles and problems of the preparation of antibodies are discussed, some methods for the preparation of derivatives labelled with radioactive tracers or enzymes are reviewed, and homologous enzyme-immunological determination of gentamicin is discussed in detail. A comparison is mae of three radio-immunological determination methods, and the most suitable radio-immunological method is compared with two microbiological techniques. The results are found to be comparable. (Auth.)

  6. Assessment of sensitivity and specificity of first, second, and third generation EIA for the detection of antibodies to HIV-1 in oral fluid.

    Science.gov (United States)

    Louie, Brian; Lei, John; Liska, Sally; Dowling, Teri; Pandori, Mark W

    2009-07-01

    The performances of three blood-based immunoassays test kits were compared with regard to their ability to detect HIV-1 antibody in oral fluid. It was found that these three kits differ in their ability to detect HIV-1 antibody. Notably, a third generation EIA which has been shown to possess superior sensitivity for antibody detection in plasma appears to possess no sensitivity advantage for detecting HIV-1 antibody in oral fluid.

  7. Improvement of an enzyme immunosorbent assay for detecting antibodies against Dioctophyma renale.

    Science.gov (United States)

    Pedrassani, Daniela; do Nascimento, Adjair Antonio; André, Marcos Rogério; Machado, Rosangela Zacarias

    2015-09-15

    An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Central nervous system blastomycosis diagnosed using the MVista® Blastomyces quantitative antigen enzyme immunoassay test on cerebrospinal fluid: A case report and review of the literature.

    Science.gov (United States)

    Walkty, Andrew; Keynan, Yoav; Karlowsky, James; Dhaliwal, Perry; Embil, John

    2018-02-01

    Blastomyces dermatitidis is a thermally dimorphic fungus that is capable of causing pulmonary and extra-pulmonary disease, including infections of the central nervous system (CNS). Diagnosis of CNS blastomycosis with non-invasive testing can be difficult, and a surgical biopsy may ultimately be required for microbiological and/or histopathological confirmation. A case of B. dermatitidis meningitis is presented where the diagnosis was made by testing cerebrospinal fluid (CSF) using the MVista® Blastomyces Quantitative Antigen Enzyme Immunoassay test. The utility of performing this test on CSF for diagnosis of CNS mass lesions/abscesses caused by B. dermatitidis in the absence of associated meningitis remains unclear. Cross reaction of the Blastomyces antigen test with other dimorphic fungi is a concern, necessitating that positive test results are interpreted in the context of the patient's exposure and travel history. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Antibody responses of cervids (Cervus elaphus) following experimental Mycobacterium bovis infection and the implications for immunodiagnosis.

    Science.gov (United States)

    Harrington, Noel P; Surujballi, Om P; Prescott, John F; Duncan, J Robert; Waters, W Ray; Lyashchenko, Konstantin; Greenwald, Rena

    2008-11-01

    Captive and free-ranging wildlife animals are implicated in the maintenance and transmission of bovine tuberculosis and therefore pose a significant obstacle to eradication of the disease from domestic livestock. The current antemortem diagnostic method, the intradermal tuberculin skin test, is impractical for routine use with many wild animals. Antibody-based assays are particularly attractive because the animals are handled only once and immediate processing of the sample is not required. This report characterizes the antibody responses of red deer-elk hybrids (Cervus elaphus) against Mycobacterium bovis and subsequently evaluates the diagnostic performance of select antigens in a rapid-test format. Sequential serum samples were collected from 10 animals experimentally infected with M. bovis and 5 noninfected animals over a 7-month period postinfection (p.i.). Samples were evaluated by enzyme-linked immunosorbent assays, immunoblot analyses, and multiantigen print immunoassays for seroreactivity to mycobacterial antigens. Although all infected animals produced antibodies to M. bovis protein antigens, there was significant animal-to-animal variation in the kinetics and magnitudes of responses and the antigens recognized. The most frequently recognized antigens included MPB83, ESAT-6, CFP10, and MPB70. Responses to some antigens, such as MPB83, were consistently detected as early as 4 weeks after inoculation, whereas other antigens were detected only much later (>140 days p.i.). Antibody responses were boosted by injection of tuberculin for intradermal tuberculin skin testing. Comparison of single-antigen (fluorescence polarization assay) with multiantigen (CervidTB STAT-PAK) rapid tests demonstrated that a highly sensitive and specific serodiagnostic test for tuberculosis in cervids will require multiple and carefully selected seroreactive antigens covering a broad spectrum of antibody specificities.

  10. Identification of anti-HPA-1a allo-antibodies using IgG platelet antibody detection and crossmatch system assay with Galileo Echo.

    Science.gov (United States)

    Di Cristofaro, Julie; Frassati, Coralie; Montagnie, Rolande; Basire, Agnes; Merieux, Yves; Picard, Christophe

    2015-01-01

    Fetal/neonatal allo-immune thrombocytopenia is the most frequent and the most dangerous clinical condition involving anti-human platelet antigens (HPA)-1a allo-antibodies. Anti-HPA-1a allo-immunization requires rapid and accurate diagnosis to determine appropriate treatment. The Capture-P Ready-Screen assay (C-PRS) is a new qualitative immunoassay to detect IgG anti-human leukocyte antigen (HLA) and anti-HPA allo-antibodies. The aim of this study is to assess the identification of anti-HPA-1a allo-antibodies using the C-PRS assay, associated with HLA class I stripping reagents, on the automated benchtop analyzer Galileo Echo. Forty-nine sera were analyzed: without anti-HLA class I or anti-HPA allo-antibodies, with anti-HLA class I allo-antibodies, with anti-HPA-1a allo-antibodies, among which with anti-HLA class I allo-antibodies. None of the samples without allo-antibodies were reactive. Only anti-HLA antibodies, detected by cytotoxicity-dependent complement and not by Luminex, remained positive before and after stripping reagents. Of the 13 samples, anti-HPA-1a allo-antibodies that were correctly identified before and after incubation with HLA assassin reagent were 70% and 85%, respectively. Anti-glycoprotein auto-antibodies and anti-HLA allo-antibodies do not interfere with the detection of anti-HPA-1a antibodies. This preliminary study indicates that further improvement of the test will be helpful in developing a clinically useful assay in the future.

  11. Evaluation of performance of human immunodeficiency virus antigen/antibody combination assays in Taiwan.

    Science.gov (United States)

    Chang, Chun-Kai; Kao, Cheng-Feng; Lin, Pi-Han; Huang, Hui-Lin; Ho, Shu-Yuan; Wong, Kuo-Chen; Lin, Bo-Chang; Yeh, Chang-Ching; Lee, Chia-Yeh; Kao, Chuan-Liang; Lee, Chun-Nan; Chang, Sui-Yuan; Yang, Jyh-Yuan

    2017-08-01

    The fourth-generation human immunodeficiency virus (HIV) combination assay, which can simultaneously detect the presence of anti-HIV antibody and HIV antigen, has been shown to shorten the window period in HIV diagnosis compared with the third-generation HIV antibody immunoassay. This study was aimed to determine the performance of HIV combination assays in Taiwan, where the HIV-1 seroprevalence is 0.007% and HIV-2 infection has never been reported. Performance of three fourth-generation HIV Ag/Ab combination assays (Dia.Pro, Wantai, and Bio-Rad) and one third-generation HIV Ab immunoassay (AxSYM HIV 1/2 gO) was assessed. A total of 152 specimens, including 86 confirmed HIV-seropositive and 66 HIV-seronegative samples, were used in the study. The sensitivity of four assays varied from 98.8% to 100%, and specificity varied from 98.5% to 100%. Performance of the 75 equivocal samples, the HIV status of which was confirmed later, in terms of negative prediction varied from 81.8% to 87.5%. The Bio-Rad and Dia.Pro assays exhibited higher sensitivity for the detection of p24 antigen among the three fourth-generation HIV combination assays. The three fourth-generation HIV Ag/Ab combination assays exhibited better sensitivity, specificity, and negative prediction than the third-generation HIV Ab immunoassay. Copyright © 2015. Published by Elsevier B.V.

  12. Monoclonal antibody-based serological methods for detection of Cucumber green mottle mosaic virus

    Directory of Open Access Journals (Sweden)

    Qian Yajuan

    2011-05-01

    Full Text Available Abstract Background Cucumber green mottle mosaic virus (CGMMV, a member of the genus Tobamovirus, can be transmitted by seeds and infects many cucurbit species, causing serious yield losses in cucumber and watermelon plants. In this paper, five serological methods including antigen-coated plate enzyme-linked immunosorbent assay (ACP-ELISA, triple antibody sandwich enzyme-linked immunosorbent assay (TAS-ELISA, Dot-immunobinding assay (DBIA, direct tissue blot immunoassay (DTBIA and immunocapture reverse transcriptase polymerase chain reaction (IC-RT-PCR were described for detection and diagnosis of CGMMV. Results Using the purified CGMMV particles as immunogens, six murine monoclonal antibodies (MAbs were produced. Five serological methods were established using the MAb 4H1 and detection sensitivity was compared using purified preparations and infected-plant tissue extracts. The detection sensitivity of ACP-ELISA was 0.16 ng of purified CGMMV, whereas TAS-ELISA was more sensitive than ACP-ELISA with a minimum detection of 0.04 ng of purified CGMMV. The sensitivities of TAS-ELISA and DBIA were similar for detecting CGMMV in infected-plant tissue extracts, and were four times higher than ACP-ELISA. The IC-RT-PCR was the most sensitive method, which could detect as little as 0.1 pg of purified virus. The detection sensitivity of IC-RT-PCR for CGMMV-infected plant tissues was about 400 times higher than that of TAS-ELISA and DBIA. Conclusions The established ACP-ELISA, TAS-ELISA, DBIA and DTBIA are suitable for routine CGMMV detection of large-scale samples in the field survey, while IC-RT-PCR is more sensitive and suitable for acquiring information about the viral genome.

  13. Electron spin resonance spectroscopy for immunoassay using iron oxide nanoparticles as probe.

    Science.gov (United States)

    Jiang, Jia; Tian, Sizhu; Wang, Kun; Wang, Yang; Zang, Shuang; Yu, Aimin; Zhang, Ziwei

    2018-02-01

    With the help of iron oxide nanoparticles, electron spin resonance spectroscopy (ESR) was applied to immunoassay. Iron oxide nanoparticles were used as the ESR probe in order to achieve an amplification of the signal resulting from the large amount of Fe 3+ ion enclosed in each nanoparticle. Rabbit IgG was used as antigen to test this method. Polyclonal antibody of rabbit IgG was used as antibody to detect the antigen. Iron oxide nanoparticle with a diameter of either 10 or 30 nm was labeled to the antibody, and Fe 3+ in the nanoparticle was probed for ESR signal. The sepharose beads were used as solid phase to which rabbit IgG was conjugated. The nanoparticle-labeled antibody was first added in the sample containing antigen, and the antigen-conjugated sepharose beads were then added into the sample. The nanoparticle-labeled antibody bound to the antigen on sepharose beads was separated from the sample by centrifugation and measured. We found that the detection ranges of the antigen obtained with nanoparticles of different sizes were different because the amount of antibody on nanoparticles of 10 nm was about one order of magnitude higher than that on nanoparticles of 30 nm. When 10 nm nanoparticle was used as probe, the upper limit of detection was 40.00 μg mL -1 , and the analytical sensitivity was 1.81 μg mL -1 . When 30 nm nanoparticle was used, the upper limit of detection was 3.00 μg mL -1 , and the sensitivity was 0.014 and 0.13 μg mL -1 depending on the ratio of nanoparticle to antibody. Graphical abstract Schematic diagram of procedure and ESR spectra.

  14. Comparison of an enzyme linked immunosorbent assay (ELISA) and a radioallergosorbent test (RAST) for detection of IgE antibodies to Brugia malayi

    NARCIS (Netherlands)

    Wahyuni, Sitti; van Ree, Ronald; Mangali, Andarias; Supali, Taniawati; Yazdanbakhsh, Maria; Sartono, Erliyani

    2003-01-01

    The enzyme linked immunosorbent assay (ELISA) for specific IgE antibodies to Brugia malayi was compared with the radioallergosorbent test (RAST) for use in immunoepidemiological studies of lymphatic filariasis. Sera used were from individuals (aged 5-82 years) living in an area endemic for lymphatic

  15. Evaluation of a commercial competitive enzyme-linked immunosorbent assay for detection of avian influenza virus subtype H5 antibodies in zoo birds

    DEFF Research Database (Denmark)

    Jensen, Trine Hammer; Andersen, Jannie Holmegaard; Hjulsager, Charlotte Kristiane

    2017-01-01

    The hemagglutination inhibition (HI) test is the current gold standard for detecting antibodies to avian influenza virus (AIV). Enzyme-linked immunosorbent assays (ELISAs) have been explored for use in poultry and certain wild bird species because of high efficiency and lower cost. This study com...

  16. The added value of hepatitis E diagnostics in determining causes of hepatitis in routine diagnostic settings in the Netherlands

    NARCIS (Netherlands)

    Doting, M. H. E.; Weel, J.; Niesters, H. G. M.; Riezebos-Brilman, A.; Brandenburg, A.

    OBJECTIVES: Hepatitis E virus (HEV) genotype 3 is endemic in Europe and an underdiagnosed and emerging (public) health issue. In recent years commercial enzyme immunoassays (EIAs) that detect antibodies to HEV more adequately, became available. We investigated the added value of this HEV serology in

  17. Help in the Choice of Automated or Semiautomated Immunoassays for Serological Diagnosis of Toxoplasmosis: Evaluation of Nine Immunoassays by the French National Reference Center for Toxoplasmosis.

    Science.gov (United States)

    Villard, O; Cimon, B; L'Ollivier, C; Fricker-Hidalgo, H; Godineau, N; Houze, S; Paris, L; Pelloux, H; Villena, I; Candolfi, E

    2016-12-01

    Toxoplasmosis, a benign infection, is asymptomatic or paucisymptomatic in over 80% of cases, except in immunocompetent patients suffering from ocular toxoplasmosis or in immunocompromised patients with opportunistic or congenital toxoplasmosis. Diagnosis is based mainly on serology testing. Thus, we compared the performance of the nine most commonly used commercial automated or semiautomated immunoassays for IgG and IgM Toxoplasma gondii antibody detection, that is, the Advia Centaur, Architect, AxSYM, Elecsys, Enzygnost, Liaison, Platelia, VIDAS, and VIDIA assays. The assays were conducted on four panels of serum samples derived during routine testing from patients with an interfering disease and who exhibited a low IgG antibody level in one of two clinical settings, namely, acute or chronic toxoplasmosis. As a result, IgG sensitivities ranged from 97.1% to 100%, and IgG specificities ranged from 99.5% to 100%. For IgG quantification, strong differences in IgG titers (expressed in IU/ml) were noted depending on the assay used. IgM sensitivities ranged from 65% to 97.9%, and IgM specificities ranged from 92.6% to 100%. For defining the best serological strategies to be implemented, it appears crucial to compare the diagnostic performance of the different tests with respect to their specificity and sensitivity in detecting the presence of IgG and IgM antibodies. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  18. A comprehensive immunoassay for the detection of microcystins in waters based on polyclonal antibodies

    International Nuclear Information System (INIS)

    Sheng Jianwu; He Miao; Shi Hanchang; Qian Yi

    2006-01-01

    Microcystins (MCs) are a group of closely related toxic cyclic heptapeptides produced by common cyanobacteria (blue-green algae), and microcystin-leucine-arginine (MC-LR) is among the most frequent and most toxic microcystin congeners. In this study, a free amino group was introduced to MC-LR at its seventh amino acid residue with 2-mercaptoethylamine, and the product aminoethyl-MC-LR was coupled to bovine serum albumin (BSA) and horseradish peroxidise (HRP) by glutaraldehyde to be complete antigen (MC-LR-BSA) and labelled hapten (MC-LR-HRP), respectively. Polyclonal antibodies against MC-LR were generated by immunization with MC-LR-BSA. A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was established to detect the MCs in waters, which showed a good cross-reactivity with MC-LR, MC-RR, MC-YR, MC-LF, MC-LW and nodularin, and have a detection limit for MC-LR 0.12 μg L -1 , the 50% inhibition concentration (IC 50 ) for MC-LR was 0.63 ± 0.06 μg L -1 and the quantitative detection range was from 0.17 to 2.32 μg L -1 , the analysis result of water samples showed good recovery and reliability. So the comprehensive and reliable dc-ELISA will well potentially suit for sensitive analysis for total MCs in drinking as well as resource water samples

  19. [Membrane-filtration immunoassay: reagents, methods and the diagnostic and technical means for detection].

    Science.gov (United States)

    Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A

    1999-01-01

    The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.

  20. Helicobacter pylori, hepatitis viruses A, C, E antibodies and HBsAg-prevalence and associated risk factors in pediatric communities of karachi

    International Nuclear Information System (INIS)

    Aziz, S.; Muzzafar, R.; Hafiz, S.; Abbas, Z.; Zafar, M.N.; Naqvi, S.A.A.; Rizvi, S.A.U.H.

    2007-01-01

    To document the prevalence of Helicobacter pylori (H. pylori), Hepatitis A virus (HAV), Hepatitis C virus (HCV), Hepatitis E virus (HEV) antibodies and Hepatitis B virus surface antigen (HBsAg), in the pediatric age group of low socioeconomic urban communities of Karachi and to identify risk factors associated with these infections. Three hundred and eighty children, ages 5 months to 15 years were investigated. Venous blood samples were collected and questionnaire filled on sociodemographic characteristics (family income, number of dependents in the family, area of living, number of people per room per house, and number of children sharing bed with parents and siblings). Gastrointestinal symptoms were recorded. Anti-HAV IgG (Hepatitis A virus IgG antibody), anti-HCV (Hepatitis C virus antibody), anti-HEV (Hepatitis E antibodies) and HBsAg, were analyzed by enzyme immunoassays (EIAs). Samples were also screened for anti-HIV1/2 (human immunodeficiency virus 1 and 2 antibodies by EIA. IgG antibodies against H. pylori were detected by immunochromatography. A correlation between increasing age and seroconversion was seen for hepatotropic viruses. At 14 years and above,100% of the children were found to be positive for anti-HAV, 26% for anti-HEV, and 1.4%, for anti-HCV while HBsAg was positive in 1.9%. H. pylori infection did not show a significant increase with age. Both anti-HAV and anti-H. pylori were present simultaneously in 30% of the population investigated. With age, increasing number of children acquired antibodies against hepatotropic viruses and H. pylori. Occurrence of HBsAg and anti-HEV at a later age suggests horizontal, rather than vertical transmission. (author)