WorldWideScience

Sample records for antibodies provide detection

  1. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    International Nuclear Information System (INIS)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M.

    1982-01-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys. (Auth.)

  2. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    Energy Technology Data Exchange (ETDEWEB)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M. (National Inst. for Biological Standards and Control, London (UK))

    1982-10-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys.

  3. Selective detection of antibodies in microstructured polymer optical fibers

    DEFF Research Database (Denmark)

    Jensen, Jesper Bo Damm; Hoiby, P.E.; Emiliyanov, Grigoriy Andreev

    2005-01-01

    was applied to selectively capture either α-streptavidin or α-CRP antibodies inside these air holes. A sensitive and easy-to-use fluorescence method was used for the optical detection. Our results show that mPOF based biosensors can provide reliable and selective antibody detection in ultra small sample......We demonstrate selective detection of fluorophore labeled antibodies from minute samples probed by a sensor layer of complementary biomolecules immobilized inside the air holes of microstructured Polymer Optical Fiber (mPOF). The fiber core is defined by a ring of 6 air holes and a simple procedure...

  4. Clinical cytometry and progress in HLA antibody detection.

    Science.gov (United States)

    Bray, Robert A; Tarsitani, Christine; Gebel, Howard M; Lee, Jar-How

    2011-01-01

    For most solid organ and selected stem cell transplants, antibodies against mismatched HLA antigens can lead to early and late graft failure. In recognition of the clinical significance of these antibodies, HLA antibody identification is one of the most critical functions of histocompatibility laboratories. Early methods employed cumbersome and insensitive complement-dependent cytotoxicity assays with a visual read-out. A little over 20 years ago flow cytometry entered the realm of antibody detection with the introduction of the flow cytometric crossmatch. Cytometry's increased sensitivity and objectivity quickly earned it popularity as a preferred crossmatch method especially for sensitized recipients. Although a sensitive method, the flow crossmatch was criticized as being "too sensitive" as false positive reactions were a know drawback. In part, the shortcomings of the flow crossmatch were due to the lack of corresponding sensitive and specific HLA antibody screening assays. However, in the mid 1990s, solid phase assays, capable of utilizing standard flow cytometers, were developed. These assays used microparticles coated with purified HLA molecules. Hence, the era of solid-phase, microparticle technology for HLA antibody detection was born permitting the sensitive and specific detection of HLA antibody. It was now possible to provide better correlation between HLA antibody detection and the flow cytometric crossmatch. This flow-based technology was soon followed by adaptation to the Luminex platform permitting a mutltiplexed approach for the identification and characterization of HLA antibodies. It is hoped that these technologies will ultimately lead to the identification of parameters that best correlate with and/or predict transplant outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Antibody-nanoparticle conjugates to enhance the sensitivity of ELISA-based detection methods.

    Directory of Open Access Journals (Sweden)

    Margaret M Billingsley

    Full Text Available Accurate antigen detection is imperative for clinicians to diagnose disease, assess treatment success, and predict patient prognosis. The most common technique used for the detection of disease-associated biomarkers is the enzyme linked immunosorbent assay (ELISA. In an ELISA, primary antibodies are incubated with biological samples containing the biomarker of interest. Then, detectible secondary antibodies conjugated with horseradish peroxidase (HRP bind the primary antibodies. Upon addition of a color-changing substrate, the samples provide a colorimetric signal that directly correlates to the targeted biomarker concentration. While ELISAs are effective for analyzing samples with high biomarker content, they lack the sensitivity required to analyze samples with low antigen levels. We hypothesized that the sensitivity of ELISAs could be enhanced by replacing freely delivered primary antibodies with antibody-nanoparticle conjugates that provide excess binding sites for detectible secondary antibodies, ultimately leading to increased signal. Here, we investigated the use of nanoshells (NS decorated with antibodies specific to epidermal growth factor receptor (EGFR as a model system (EGFR-NS. We incubated one healthy and two breast cancer cell lines, each expressing different levels of EGFR, with EGFR-NS, untargeted NS, or unconjugated EGFR antibodies, as well as detectable secondary antibodies. We found that EGFR-NS consistently increased signal intensity relative to unconjugated EGFR antibodies, with a substantial 13-fold enhancement from cells expressing high levels of EGFR. Additionally, 40x more unconjugated antibodies were required to detect EGFR compared to those conjugated to NS. Our results demonstrate that antibody-nanoparticle conjugates lower the detection limit of traditional ELISAs and support further investigation of this strategy with other antibodies and nanoparticles. Owing to their enhanced sensitivity, we anticipate that

  6. Photonic crystal fiber based antibody detection

    DEFF Research Database (Denmark)

    Duval, A; Lhoutellier, M; Jensen, J B

    2004-01-01

    An original approach for detecting labeled antibodies based on strong penetration photonic crystal fibers is introduced. The target antibody is immobilized inside the air-holes of a photonic crystal fiber and the detection is realized by the means of evanescent-wave fluorescence spectroscopy...

  7. Monoclonal antibody technologies and rapid detection assays

    Science.gov (United States)

    Novel methodologies and screening strategies will be outlined on the use of hybridoma technology for the selection of antigen specific monoclonal antibodies. The development of immunoassays used for diagnostic detection of prions and bacterial toxins will be discussed and examples provided demonstr...

  8. Synthetic oligonucleotide antigens modified with locked nucleic acids detect disease specific antibodies

    DEFF Research Database (Denmark)

    Samuelsen, Simone V; Solov'yov, Ilia A.; Balboni, Imelda M.

    2016-01-01

    New techniques to detect and quantify antibodies to nucleic acids would provide a significant advance over current methods, which often lack specificity. We investigate the potential of novel antigens containing locked nucleic acids (LNAs) as targets for antibodies. Particularly, employing...... molecular dynamics we predict optimal nucleotide composition for targeting DNA-binding antibodies. As a proof of concept, we address a problem of detecting anti-DNA antibodies that are characteristic of systemic lupus erythematosus, a chronic autoimmune disease with multiple manifestations. We test the best...... that the novel method is a promising tool to create antigens for research and point-of-care monitoring of anti-DNA antibodies....

  9. Generalized Platform for Antibody Detection using the Antibody Catalyzed Water Oxidation Pathway

    OpenAIRE

    Welch, M. Elizabeth; Ritzert, Nicole L.; Chen, Hongjun; Smith, Norah L.; Tague, Michele E.; Xu, Youyong; Baird, Barbara A.; Abru?a, H?ctor D.; Ober, Christopher K.

    2014-01-01

    Infectious diseases, such as influenza, present a prominent global problem including the constant threat of pandemics that initiate in avian or other species and then pass to humans. We report a new sensor that can be specifically functionalized to detect antibodies associated with a wide range of infectious diseases in multiple species. This biosensor is based on electrochemical detection of hydrogen peroxide generated through the intrinsic catalytic activity of all antibodies: the antibody ...

  10. [Immunochemical Detection of Azospirilla in Soil with Genus-Specific Antibodies].

    Science.gov (United States)

    Shirokov, A A; Krasov, A I; Selivanov, N Yu; Burygin, G L; Shchegolev, S Yu; Matora, L Yu

    2015-01-01

    Immunoelectrophoresis and immunodiffusion analysis with antibodies to whole intact cells of the type strain of nitrogen-fixing soil bacteria Azospirillum brasilense Sp7 revealed at least three conservative surface immunogenic proteins of azospirilla. Cross-reactions with these proteins made it possible to use the above antibodies for detection of azospirilla as a genus-specific probe conjugated with horseradish peroxidase as an enzymatic label. Direct immune-enzyme analysis of soil suspensions (typical chernozem, Saratov oblast) confirmed applicability of the conjugates based on genus-specific antibodies to the surface proteins of azospirilla for direct detection of this bacterial genus in environmental samples. These results provide a basis for broad application of this method for analysis of Azospirillum occurrence in soil.

  11. Detection of Antibodies in Blood Plasma Using Bioluminescent Sensor Proteins and a Smartphone.

    Science.gov (United States)

    Arts, Remco; den Hartog, Ilona; Zijlema, Stefan E; Thijssen, Vito; van der Beelen, Stan H E; Merkx, Maarten

    2016-04-19

    Antibody detection is of fundamental importance in many diagnostic and bioanalytical assays, yet current detection techniques tend to be laborious and/or expensive. We present a new sensor platform (LUMABS) based on bioluminescence resonance energy transfer (BRET) that allows detection of antibodies directly in solution using a smartphone as the sole piece of equipment. LUMABS are single-protein sensors that consist of the blue-light emitting luciferase NanoLuc connected via a semiflexible linker to the green fluorescent acceptor protein mNeonGreen, which are kept close together using helper domains. Binding of an antibody to epitope sequences flanking the linker disrupts the interaction between the helper domains, resulting in a large decrease in BRET efficiency. The resulting change in color of the emitted light from green-blue to blue can be detected directly in blood plasma, even at picomolar concentrations of antibody. Moreover, the modular architecture of LUMABS allows changing of target specificity by simple exchange of epitope sequences, as demonstrated here for antibodies against HIV1-p17, hemagglutinin (HA), and dengue virus type I. The combination of sensitive ratiometric bioluminescent detection and the intrinsic modularity of the LUMABS design provides an attractive generic platform for point-of-care antibody detection that avoids the complex liquid handling steps associated with conventional immunoassays.

  12. A sensitive radioimmunoassay for the detection of monoclonal anti-idiotype antibodies

    International Nuclear Information System (INIS)

    Morahan, G.

    1983-01-01

    A radioimmunoassay was developed in order to detect anti-idiotypic antibodies in the supernatants of hybrid cells. This assay is both sensitive and specific for anti-idiotypic (but not anti-allotypic) antibodies. Monoclonal antibodies present in test supernatants are bound by an anti-immunoglobulin coated solid phase. Subsequent incubation with a source of mouse immunoglobulin 'blocks' unreacted anti-immunoglobulin antibodies on the solid phase. Anti-idiotypic antibodies are then detected by their ability to bind 125 I-labelled idiotype-bearing antibody. This paper describes the use of this assay to detect monoclonal anti-idiotypic antibodies in 2 systems; the cross-reactive idiotype of A/J anti-ABA antibodies, and the idiotype expressed by the myeloma protein HOPC 8. Similarly, 125 I-labelled anti-idiotype antibodies may be used in this assay to detect monoclonal idiotype-bearing antibodies. Further modifications are described which would allow the detection of monoclonal anti-allotype antibodies. (Auth.)

  13. Egg yolk antibodies for detection and neutralization of Clostridium botulinum type A neurotoxin.

    Science.gov (United States)

    Trott, D L; Yang, M; Gonzalez, J; Larson, A E; Tepp, W H; Johnson, E A; Cook, M E

    2009-05-01

    The objective of this research project was to determine the usefulness of an egg antibody platform for producing materials for the detection and neutralization of botulinum type A neurotoxin. Yield estimates for detection and neutralizing antibodies produced using methods described were calculated. Antibody specific to botulinum toxoid A (aToxoid) and toxin A (aBoNT/A) was produced by immunizing hens with botulinum toxoid A (toxoid) followed by increasing amounts of botulinum neurotoxin A (BoNT/A) in Freund incomplete adjuvant. Egg yolks were extracted with polyethylene glycol (PEG) for antibody detection and neutralization experiments. A model aToxoid/toxoid immunoassay using only egg yolk antibody was developed and had a detection limit of 1 pg/ml of toxoid. In an indirect enzyme-linked immunosorbent assay of BoNT/A-specific antibody, the aBoNT/A contained more BoNT/A-specific antibody than did the aToxoid, and aBoNT/A was as effective as commercial rabbit antibody. The aToxoid provided no protection against BoNT/A in a standard mouse neutralization assay; however, 1 mg of PEG-extracted aBoNT/A neutralized 4,000 lethal doses of BoNT/A injected intraperitoneally. Based on these results, we calculated that in 1 month one hen could produce more than 100 liters of antibody detection reagents or enough antibody to neutralize approximately 11.6 million mouse lethal doses of botulinum toxin. Utilization of an egg antibody platform is potentially rapid (28 to 70 days) and scalable to kilogram quantities using current egg production facilities with as few as 1,000 hens.

  14. Novel HIT antibody detection method using Sonoclot® coagulation analyzer.

    Science.gov (United States)

    Wanaka, Keiko; Asada, Reiko; Miyashita, Kumiko; Kaneko, Makoto; Endo, Hirokazu; Yatomi, Yutaka

    2015-01-01

    Since heparin-induced thrombocytopenia (HIT), caused by the generation of antibodies against platelet factor 4 (PF4)/heparin complexes (HIT antibodies), may induce serious complications due to thrombosis, a prompt diagnosis is desirable. Functional tests with platelet activation to detect HIT antibodies are useful for diagnosis of HIT, in particular (14)C-selotonin release assay (SRA). However, they are complicated and so can be performed only in limited laboratories. We tested if a blood coagulation test using Sonoclot® analyzer can serve for the detection of HIT antibodies. A murine monoclonal antibody (HIT-MoAb) against PF4/heparin complexes was used as an alternative to human HIT antibodies. To the mixture of HIT-MoAb and heparin (0.5 U/mL, final), whole blood obtained from a healthy volunteer was added, and then the activated clotting time (ACT), clot rate (CR), and area under the curve (AUC) were measured with Sonoclot® analyzer for 30minutes. The HIT-MoAb (30 to 100μg/mL, final) concentration dependently suppressed the anticoagulation activity (prolongation of ACT and decrease of CR and AUC) of heparin. The suppression of anticoagulation effect of heparin by HIT-MoAb was demonstrated by measurements using Sonoclot® analyzer. This method may provide a new tool for screening of HIT antibodies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Detecting Lyme disease using antibody-functionalized carbon nanotubes

    Science.gov (United States)

    Dailey, Jennifer; Lerner, Mitchell; Goldsmith, Brett; Brisson, Dustin; Johnson, A. T. Charlie

    2011-03-01

    We combine antibodies for Lyme flagellar protein with carbon nanotube transistors to create an electronic sensor capable of definitive detection of Lyme disease. Over 35,000 cases of Lyme disease are reported in the United States each year, of which more than 23 percent are originally misdiagnosed. Rational design of the coupling of the biological system to the electronic system gives us a flexible sensor platform which we can apply to several biological systems. By coupling these antibodies to carbon nanotubes in particular, we allow for fast, sensitive, highly selective, electronic detection. Unlike antibody or biomarker detection, bacterial protein detection leads to positive identification of both early and late stage bacterial infections, and is easily expandable to environmental monitoring.

  16. Radioimmunoassay method for detection of gonorrhea antibodies

    International Nuclear Information System (INIS)

    1975-01-01

    A novel radioimmunoassay for the detection of gonorrhea antibodies in serum is described. A radionuclide is bound to gonorrhea antigens produced by a growth culture. In the presence of gonorrhea antibodies in the serum, an antigen-antibody conjugate is formed, the concentration of which can be measured with conventional radiometric methods. The radioimmunoassay is highly specific

  17. 42 CFR 493.861 - Standard; Unexpected antibody detection.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard; Unexpected antibody detection. 493.861 Section 493.861 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN..., Or Any Combination of These Tests § 493.861 Standard; Unexpected antibody detection. (a) Failure to...

  18. Detection of anti-lactoferrin antibodies and anti-myeloperoxidase antibodies in autoimmune hepatitis: a retrospective study.

    Science.gov (United States)

    Tan, Liming; Zhang, Yuhong; Peng, Weihua; Chen, Juanjuan; Li, Hua; Ming, Feng

    2014-01-01

    Anti-lactoferrin antibodies (ALA) and anti-myeloperoxidase antibodies (AMPA) are specific serological markers for autoimmune hepatitis (AIH). The project aimed to detect ALA and AMPA and explore their clinical significances in AIH patients. 59 AIH patients, 217 non AIH patients, and 50 healthy controls were enrolled in this study. ALA and AMPA were detected by ELISA. Antineutropil cytoplasmic antibodies (ANCA) and anti-smooth muscle antibodies (ASMA) were examined by indirect immunofluorescence. Antimitochondrial antibody M2 subtype (AMA-M2), anti-liver kidney microsomal antibody Type 1 (LKM1), anti-liver cytosol antibody Type 1 (LC1), and anti-soluble liver antigen/liver-pancreas antibodies (SLA/LP) were tested by immunoblot. The positivity for ALA was 18.6% in AIH group, only one patient in non-AIH group was positive for ALA; the positivity for AMPA was 59.3% in AIH group, with significant differences (P < 0.01) compared with other groups. The specificities for ALA and AMPA were 99.63% and 97.75%; the sensitivities were 18.64% and 59.32%; and the accuracy rates were 84.97% and 90.80%, respectively. A certain correlation was observed between ALA and SLA/LP, AMPA and ANCA, ASMA in AIH group. ALA and AMPA were associated with AIH, and had high clinical diagnostic value. Co-detection with other relative autoantibodies could play an important role in differential diagnosis of AIH.

  19. Bulk tank milk ELISA for detection of antibodies to Mycobacterium avium subsp paratuberculosis: Correlation between repeated tests and within-herd antibody-prevalence

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils

    2014-01-01

    Detection of bulk tank milk (BTM) antibodies using ELISA (BTM-ELISA) may constitute an inexpensive test for surveillance of Mycobacterium avium subsp. paratuberculosis (MAP) infection in dairy cattle herds provided that the test is accurate and consistent. The objectives of this study were...... Danish Holstein herds over a period of one year. All samples were tested using a commercial indirect ELISA for detection of MAP specific antibodies. The individual cow's results were dichotomised and used to estimate the within-herd antibody prevalence at each test-date. These prevalences were...... to 0.60 when corrected for the within-herd antibody prevalence. Although the test-results were relatively consistent and correlated with the within-herd prevalence, the magnitude of the test-values makes it difficult to use the BTM-ELISA for surveillance of MAP infections in practice....

  20. Radiolabeled antifibrin antibody in the detection of venous thrombosis: Preliminary results

    International Nuclear Information System (INIS)

    Alavi, A.; Palevsky, H.I.; Gupta, N.; Meranze, S.; Kelley, M.A.; Jatlow, A.D.; Schaible, T.F.; Brown, J.; Berger, H.J.

    1990-01-01

    The recent development of monoclonal antibodies against components of coagulated blood may provide new approaches to the diagnosis of venous thrombosis. Scanning with an indium-111-labeled Fab fragment of a murine monoclonal antifibrin antibody (59D8) and ascending contrast venography were performed in 33 patients. Images of the calves, popliteal fossae, thighs, and pelvis were obtained immediately, 4-6 hours, and 24 hours after injection of 2 mCi (74 MBq) of the antibody. All images were read in a blinded manner. Findings in both studies were positive in 28 patients and negative in three. In 19 patients not undergoing heparin therapy, 19 specific anatomic sites were positive on venograms and 29 were positive on antibody images (19 sites matched). In 14 patients undergoing heparin therapy, 34 sites were positive on venograms and 27 were positive on antibody images (22 sites matched). In most patients, positive results were noted within 1 hour of antibody injection. No adverse effects were noted with the antibody preparation. Preliminary data suggest that antifibrin antibody imaging is sensitive in detecting clots, is safe to use, and may have a role in diagnosing and managing venous thrombosis

  1. Radiometric immunosorbent assay for the detection of anti-hormone-binding protein antibodies

    International Nuclear Information System (INIS)

    Pierce, E.A.; Dame, M.C.; DeLuca, H.F.

    1986-01-01

    A radiometric immunosorbent assay (RISA) for the detection of monoclonal antibodies to hormone-binding proteins has been developed. The assay involves incubating hybridoma supernatants in microtiter wells that have been coated with goat anti-mouse IgG antibodies. Any mouse IgG in the test supernatant is thus specifically retained in the wells. Radioactive ligand-binding protein complexes are then incubated in the wells. The presence of anti-binding protein antibodies in the supernatant is indicated by specific retention of radioactive ligand-binding protein complexes in the wells. Crude antigen preparations, such as tissue homogenates, can be used to detect antibodies. The assay is capable of detecting antibody at concentrations 20 ng/ml (approx. 100 pM IgG). The RISA has been used successfully to screen for monoclonal antibodies to the intracellular receptor for 1,25-dihydroxyvitamin D 3 and should be useful for the detection of antibodies to ligand-binding proteins in general

  2. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    International Nuclear Information System (INIS)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-01-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation

  3. Standardized Methods for Detection of Poliovirus Antibodies.

    Science.gov (United States)

    Weldon, William C; Oberste, M Steven; Pallansch, Mark A

    2016-01-01

    Testing for neutralizing antibodies against polioviruses has been an established gold standard for assessing individual protection from disease, population immunity, vaccine efficacy studies, and other vaccine clinical trials. Detecting poliovirus specific IgM and IgA in sera and mucosal specimens has been proposed for evaluating the status of population mucosal immunity. More recently, there has been a renewed interest in using dried blood spot cards as a medium for sample collection to enhance surveillance of poliovirus immunity. Here, we describe the modified poliovirus microneutralization assay, poliovirus capture IgM and IgA ELISA assays, and dried blood spot polio serology procedures for the detection of antibodies against poliovirus serotypes 1, 2, and 3.

  4. Polyclonal antibodies for the detection of Trypanosoma cruzi circulating antigens.

    Directory of Open Access Journals (Sweden)

    Edith S Málaga-Machaca

    2017-11-01

    Full Text Available Detection of Trypanosoma cruzi antigens in clinical samples is considered an important diagnostic tool for Chagas disease. The production and use of polyclonal antibodies may contribute to an increase in the sensitivity of immunodiagnosis of Chagas disease.Polyclonal antibodies were raised in alpacas, rabbits, and hens immunized with trypomastigote excreted-secreted antigen, membrane proteins, trypomastigote lysate antigen and recombinant 1F8 to produce polyclonal antibodies. Western blot analysis was performed to determine specificity of the developed antibodies. An antigen capture ELISA of circulating antigens in serum, plasma and urine samples was developed using IgY polyclonal antibodies against T. cruzi membrane antigens (capture antibody and IgG from alpaca raised against TESA. A total of 33 serum, 23 plasma and 9 urine samples were analyzed using the developed test. Among serum samples, compared to serology, the antigen capture ELISA tested positive in 55% of samples. All plasma samples from serology positive subjects were positive in the antigen capture ELISA. All urine positive samples had corresponding plasma samples that were also positive when tested by the antigen capture ELISA.Polyclonal antibodies are useful for detection of circulating antigens in both the plasma and urine of infected individuals. Detection of antigens is direct evidence of the presence of the parasite, and could be a better surrogate of current infection status.

  5. Application of Food-specific IgG Antibody Detection in Allergy Dermatosis

    Directory of Open Access Journals (Sweden)

    Yine Hu

    2015-01-01

    Full Text Available The application of food-specific IgG antibody detection in allergy dermatoses was explored. 181 patients with allergy dermatoses were diagnosed from January to September 2014 and 20 healthy subjects were selected. Fourteen kinds of food-specific IgG antibodies were detected by ELISA method among all the subjects. The positive rates of IgG antibody of the patient group and the healthy group were respectively 65.2% and 5.0%. The positive rates of IgG antibody of egg, milk, shrimp and crab took a large proportion in three groups of patients with three kinds of allergy dermatoses of urticaria, eczema and allergic dermatitis, the proportion of which was respectively 70.2%, 77.8% and 71.7%. Among urticaria and allergic dermatitis patients with positive antibody, the positive rate of children was significantly higher than that of adults (p0.05. Allergy dermatoses are closely related to food-specific IgG antibodies, and the allergy dermatoses patients have a high incidence rate of food intolerance; detecting IgG antibody in the serum of patients is of great significance for the diagnosis and treatment of allergy dermatoses.

  6. Protein A Detection Based on Quantum Dots-Antibody Bioprobe Using Fluorescence Coupled Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Lin Qiu

    2014-01-01

    Full Text Available In this report, fluorescence detection coupled capillary electrophoresis (CE-FL was used to detect Protein A. Antibody was first labeled with Cy5 and then mixed with quantum dots (QDs to form QDs-antibody bioprobe. Further, we observed fluorescence resonance energy transfer (FRET from QDs donor to Cy5 acceptor. The bioprobe was formed and brought QDs and Cy5 close enough to allow FRET to occur. After adding protein A, the FRET system was broken and caused the FRET signal to decrease. Thus, a new method for the determination of protein A was proposed based on the FRET signal changes. This study provides a new trail of thought for the detection of protein.

  7. The use of monoclonal antibodies in competitive ELISA for the detection of antibodies to rinderpest and peste des petits ruminants viruses

    International Nuclear Information System (INIS)

    Anderson, J.; McKay, J.A.; Butcher, R.N.

    1991-01-01

    A monoclonal antibody against the haemagglutinin of rinderpest virus has been used in a competitive ELISA (C-ELISA) for the detection of antibodies to rinderpest virus in cattle, sheep, goat and game sera. Unlike the indirect ELISA and the virus neutralisation test (VNT), the C-ELISA detects only antibodies to rinderpest virus and gives no cross-reactivity with antibodies to peste des petits ruminants (PPR) virus. Antibodies to a wide range of strains of rinderpest virus have been detected using this assay, suggesting its suitability for both sero-monitoring and sero-surveillance. Analysis of C-ELISA results from the examination of field sera shows a much greater separation of negative and positive populations as compared to the indirect ELISA. A further monoclonal antibody against the H protein of PPR has also been found suitable for use in a C-ELISA for the detection of antibodies to PPR virus. The use of these two C-ELISA's has made possible rapid differential sero-diagnosis without recourse to cross-VNT testing. The use of monoclonal antibody-based assays will allow much greater standardisation of rinderpest and PPR diagnosis, and following field-trials the C-ELISA will replace the indirect ELISA for sero-monitoring throughout the Pan African Rinderpest Campaign. (author). 3 refs, 6 figs, 1 tab

  8. Towards On-site Pathogen Detection Using Antibody-based Sensors

    DEFF Research Database (Denmark)

    Skottrup, Peter Durand; Nicolaisen, Mogens; Justesen, Annemarie Fejer

    2008-01-01

    In this paper the recent progress within biosensors for plant pathogen detection will be reviewed. Bio-recognition layers on sensors can be designed in various ways, however the most popular approach is to immobilise antibodies for specific capture of analytes. Focus will be put on antibody surfa...

  9. Identification of anti-HPA-1a allo-antibodies using IgG platelet antibody detection and crossmatch system assay with Galileo Echo.

    Science.gov (United States)

    Di Cristofaro, Julie; Frassati, Coralie; Montagnie, Rolande; Basire, Agnes; Merieux, Yves; Picard, Christophe

    2015-01-01

    Fetal/neonatal allo-immune thrombocytopenia is the most frequent and the most dangerous clinical condition involving anti-human platelet antigens (HPA)-1a allo-antibodies. Anti-HPA-1a allo-immunization requires rapid and accurate diagnosis to determine appropriate treatment. The Capture-P Ready-Screen assay (C-PRS) is a new qualitative immunoassay to detect IgG anti-human leukocyte antigen (HLA) and anti-HPA allo-antibodies. The aim of this study is to assess the identification of anti-HPA-1a allo-antibodies using the C-PRS assay, associated with HLA class I stripping reagents, on the automated benchtop analyzer Galileo Echo. Forty-nine sera were analyzed: without anti-HLA class I or anti-HPA allo-antibodies, with anti-HLA class I allo-antibodies, with anti-HPA-1a allo-antibodies, among which with anti-HLA class I allo-antibodies. None of the samples without allo-antibodies were reactive. Only anti-HLA antibodies, detected by cytotoxicity-dependent complement and not by Luminex, remained positive before and after stripping reagents. Of the 13 samples, anti-HPA-1a allo-antibodies that were correctly identified before and after incubation with HLA assassin reagent were 70% and 85%, respectively. Anti-glycoprotein auto-antibodies and anti-HLA allo-antibodies do not interfere with the detection of anti-HPA-1a antibodies. This preliminary study indicates that further improvement of the test will be helpful in developing a clinically useful assay in the future.

  10. Composition and method for detecting cancer with technetium labeled antibody fragments

    International Nuclear Information System (INIS)

    Burchiel, S. W.; Crockford, D. R.; Rhodes, B. A.

    1984-01-01

    F(ab') 2 or Fab fragments of antibodies to: (a) human chorionic gonadotropin (hCG), hCG alpha subunit, hCG beta subunit, or an hCG-like material; or (b) other tumor specific or tumor associated molecules, to include carcinoembryonic antigen (CEA), alpha fetoprotein (AFP), human melanoma associated antigens, human sarcoma associated antigens or other antigens, are radiolabeled with technetium-99m (Tc-99m). When the F(ab') 2 or Fab fragments of antibody to such tumor associated antigens are injected intravenously into a patient, the radiolabeled composition accumulates at tumor sites. The accumulation of the cancer seeking radiopharmaceutical at tumor sites permits detection by external gamma scintigraphy. Thus, the composition is useful in the monitoring, localization and detection of cancer in the body. In an alternative composition, a double antibody approach to tumor localization using radiolabeled F(ab') 2 or Fab fragments is utilized. In this approach, a tumor specific antibody in the form of IgG, F(ab') 2 or Fab is first administered to a patient intravenously. Following a sufficient period of time, a second antibody in the form of F(ab') 2 or Fab is administered. The second antibody is radiolabeled with Tc-99m and has the property that it is reactive with the first antibody. This double antibody method has the advantage over a single antibody approach in that smaller tumors can be localized and detected and that the total amount of radioactive trace localized at the cancer site is increased

  11. Detection of avian influenza antibodies and antigens in poultry and ...

    African Journals Online (AJOL)

    Using HI test, the wild birds were negative for AI (H5) antibodies but ELISA detected AI (NP) antibodies in Black Stork (Ciconia nigra) with an overall seroprevalence of 4.5% and mean titre of 24.50±2.400 EU. Cloacal swabs from the same species of wild birds that were tested for antibodies and 710 oropharyngeal swabs ...

  12. Comparison of micro column technology with conventional tube methods for antibody detection

    Directory of Open Access Journals (Sweden)

    Sachin Garg

    2017-01-01

    Conclusion: MCT was found to be most efficacious when compared to CTT and tube LISS-IAT in detecting clinically significant red cell antibodies; although MCT missed 2 cases of Lea antibody which were detected by CTT and LISS-IAT.

  13. Detection of IgE insulin antibody with radioallergosorbent test

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, S; Nakayama, H; Sasaki, T; Watanabe, T; Aoki, S [Hokkaido Univ., Sapporo (Japan). 2. Dept. of Medicine; Saito, N [Sapporo Railway Hospital (Japan). Dept. of Medicine

    1978-01-01

    An in vitro method for detecting IgE insulin antibody using the principle of the radioallergosorbent test (RAST) is described. In six patients with insulin allergy, the RAST values were higher than in normal persons or insulin-treated diabetics without insulin allergy. No differences were observed between normal persons and insulin-treated diabetics without insulin allergy. Moreover, it was observed that in one patient treated with highly purified insulin, there was a gradual decrease of RAST value parallel to the radioinsulin binding activity and clinical allergic symptoms. The RAST value of insulin is slightly inhibited by non-IgE antibodies and is, therefore, a semiquantitative value. However, the RAST is simple to perform and reproducible; it is therefore very useful in the detection of IgE insulin antibodies.

  14. Detection of IgE insulin antibody with radioallergosorbent test

    International Nuclear Information System (INIS)

    Nakagawa, S.; Nakayama, H.; Sasaki, T.; Watanabe, T.; Aoki, S.; Saito, N.

    1978-01-01

    An in vitro method for detecting IgE insulin antibody using the principle of the radioallergosorbent test (RAST) is described. In six patients with insulin allergy, the RAST values were higher than in normal persons or insulin-treated diabetics without insulin allergy. No differences were observed between normal persons and insulin-treated diabetics without insulin allergy. Moreover, it was observed that in one patient treated with highly purified insulin, there was a gradual decrease of RAST value parallel to the radioinsulin binding activity and clinical allergic symptoms. The RAST value of insulin is slightly inhibited by non-IgE antibodies and is, therefore, a semiquantitative value. However, the RAST is simple to perform and reproducible; it is therefore very useful in the detection of IgE insulin antibodies. (orig.) [de

  15. Antibody Derived Peptides for Detection of Ebola Virus Glycoprotein.

    Directory of Open Access Journals (Sweden)

    Luis Mario Rodríguez-Martínez

    Full Text Available Current Ebola virus (EBOV detection methods are costly and impractical for epidemic scenarios. Different immune-based assays have been reported for the detection and quantification of Ebola virus (EBOV proteins. In particular, several monoclonal antibodies (mAbs have been described that bind the capsid glycoprotein (GP of EBOV GP. However, the currently available platforms for the design and production of full-length mAbs are cumbersome and costly. The use of antibody fragments, rather than full-length antibodies, might represent a cost-effective alternative for the development of diagnostic and possibly even therapeutic alternatives for EBOV.We report the design and expression of three recombinant anti-GP mAb fragments in Escherichia coli cultures. These fragments contained the heavy and light variable portions of the three well-studied anti-GP full-length mAbs 13C6, 13F6, and KZ52, and are consequently named scFv-13C6, scFv-13F6, and Fab-KZ52, respectively. All three fragments exhibited specific anti-GP binding activity in ELISA experiments comparable to that of full-length anti-GP antibodies (i.e., the same order of magnitude and they are easily and economically produced in bacterial cultures.Antibody fragments might represent a useful, effective, and low cost alternative to full-length antibodies in Ebola related capture and diagnostics applications.

  16. Detection of antibodies in blood plasma using bioluminescent sensor proteins and a smartphone

    NARCIS (Netherlands)

    Arts, R.; den Hartog, I.; Zijlema, S.E.; Thijssen, V.; van der Beelen, S.H.E.; Merkx, M.

    2016-01-01

    Antibody detection is of fundamental importance in many diagnostic and bioanalytical assays, yet current detection techniques tend to be laborious and/or expensive. We present a new sensor platform (LUMABS) based on bioluminescence resonance energy transfer (BRET) that allows detection of antibodies

  17. Indirect micro-immunofluorescence test for detecting type-specific antibodies to herpes simplex virus.

    Science.gov (United States)

    Forsey, T; Darougar, S

    1980-02-01

    A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.

  18. Technetium-99m pertechnetate - a tracer for radiolabelling antibody for inflammation detection

    International Nuclear Information System (INIS)

    Shaharuddin Mohd; Wan Hamirul Bahrin Wan Kamal; Shahrin A Hamid; Ang Woan Tze; Rosnani Hashim

    1999-01-01

    The polyclonal antibody, Human Immunoglobulin G (HlgG) was reduced by using 2-mercaptoethanol with molar ratio of 1000:1 (i.e. mercaptoethanol:antibody). The reduction of the antibody, was carried out for 30 minutes at room temperature. The reduced antibody was purified by using Sephadex G-25 fine column. The antibody kit for the detection of inflammation was prepared aseptically in Class 1 Laminar Flow cabinet. The kit passed the sterility test. Upon reconstitution of the antibody kit with sodium pertechnetate-99m ( 99m Tc) solution, the labelling efficiency obtained was more than 95%. This preparation was stable up to 24-hour stored at room temperature. Gamma camera scans showed the accumulation of technetium-99m labelled antibody ( 99m Tc-HIgG) at the turpentine-induced inflammation of female Sprague-Dawley rats. This indicated the possibility of using 99m Tc-HIgG for inflammation detection. (author)

  19. Detection of antisalivary duct antibody from Sjoegren's syndrome by an autoradiographic method

    International Nuclear Information System (INIS)

    Cummings, N.A.; Tarpley, T.M. Jr.

    1978-01-01

    A new technique to detect anti-salivary duct antibody (ASDA) has been developed by using autoradiographic, rather than immunofluorescent methods. The antibody activity detected by autoradiography is probably classic ASDA. Both techniques may be consecutively performed on the same tissue section without attenuation of either. Some of the potential advantages of the radiolabelling of ASDA are pointed out, and a few preliminary experiments using the labelled antibody as a marker are presented. (Auth.)

  20. Simultaneous detection of Hepatitis B surface antigen and its antibody by radioimmunoassay

    International Nuclear Information System (INIS)

    Crouzat-Reynes, Gerard; Perigois, Francois; Lecureuil, Michel; Lejeune, Bernard

    1981-01-01

    The authors describe an original radioimmunoassay which allows the simultaneous detection of hepatitis B surface antigen and its antibody in a biological sample. Antigen and antibody are indiscriminately detected in a first step and then distinguished in a second step using the same reagents [fr

  1. DNA-mediated strand displacement facilitates sensitive electronic detection of antibodies in human serums.

    Science.gov (United States)

    Dou, Baoting; Yang, Jianmei; Shi, Kai; Yuan, Ruo; Xiang, Yun

    2016-09-15

    We describe here the development of a sensitive and convenient electronic sensor for the detection of antibodies in human serums. The sensor is constructed by self-assembly formation of a mixed monolayer containing the small molecule epitope conjugated double stranded DNA probes on gold electrode. The target antibody binds the epitope on the dsDNA probe and lowers the melting temperature of the duplex, which facilitates the displacement of the antibody-linked strand of the duplex probe by an invading methylene blue-tagged single stranded DNA (MB-ssDNA) through the strand displacement reaction and leads to the capture of many MB-ssDNA on the sensor surface. Subsequent electrochemical oxidation of the methylene blue labels results in amplified current response for sensitive monitoring of the antibodies. The antibody assay conditions are optimized and the sensor exhibits a linear range between 1.0 and 25.0nM with a detection limit of 0.67nM for the target antibody. The sensor is also selective and can be employed to detect the target antibodies in human serum samples. With the advantages of using small molecule epitope as the antibody recognition element over traditional antigen, the versatile manipulability of the DNA probes and the unique properties of the electrochemical transduction technique, the developed sensor thus hold great potential for simple and sensitive detection of different antibodies and other proteins in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  3. A simple assay for the detection of antibodies to endocrine islet cell surface antigens

    International Nuclear Information System (INIS)

    Contreas, G.; Madsen, O.D.; Vissing, H.; Lernmark, Aa.

    1986-01-01

    A simple and sensitive immunoradiometric assay for the detection of islet cell surface antibodies (CIRMA) has been developed. Live, transformed islet cells derived from a liver metastasis of a transplantable islet cell tumor were grown in removable microtiter wells and incubated with antibody. Cell-bound antibodies were quantitated using 125 I-labelled second antibodies. The assay was used to detect islet cell antibodies present in sera from non-diabetic and diabetic BB rats and proved to be particularly effective for screening hybridoma supernatants in order to identify monoclonal antibodies recognizing islet cell surface antigens. (Auth.)

  4. Development of recombinant antigen array for simultaneous detection of viral antibodies.

    Directory of Open Access Journals (Sweden)

    Yi Liu

    Full Text Available Protein microarrays have been developed to study antibody reactivity against a large number of antigens, demonstrating extensive perspective for clinical application. We developed a viral antigen array by spotting four recombinant antigens and synthetic peptide, including glycoprotein G of herpes simplex virus (HSV type 1 and 2, phosphoprotein 150 of cytomegalovirus (CMV, Rubella virus (RV core plus glycoprotein E1 and E2 as well as a E1 peptide with the optimal concentrations on activated glass slides to simultaneously detect IgG and IgM against HSV1, HSV2, CMV and RV in clinical specimens of sera and cerebrospinal fluids (CSFs. The positive reference sera were initially used to measure the sensitivity and specificity of the array with the optimal conditions. Then clinical specimens of 144 sera and 93 CSFs were tested for IgG and IgM antibodies directed against HSV1, HSV2, CMV and RV by the antigen array. Specificity of the antigen array for viral antibodies detection was satisfying compared to commercial ELISA kits but sensitivity of the array varied relying on quality and antigenic epitopes of the spotting antigens. In short, the recombinant antigen array has potential to simultaneous detect multiple viral antibodies using minute amount (3 µl of samples, which holds the particularly advantage to detect viral antibodies in clinical CSFs being suspicious of neonatal meningitis and encephalitis.

  5. Complexes of DNA with fluorescent dyes are effective reagents for detection of autoimmune antibodies

    DEFF Research Database (Denmark)

    Domljanovic, Ivana; Carstens, Annika; Okholm, Anders

    2017-01-01

    as targets for these antibodies. This is done in a simple, rapid and specific immunofluorescence assay. Specifically, employing 3D nanostructures (DNA origami), we present a new approach in the detection and study of human antibodies to DNA. We demonstrate the detection of anti-DNA antibodies...

  6. Detection of anti-tetanus toxoid antibody on modified polyacrylonitrile fibers.

    Science.gov (United States)

    Jain, Swati; Chattopadhyay, Sruti; Jackeray, Richa; Zainul Abid, C K V; Kumar, Manoj; Singh, Harpal

    2010-10-15

    Accurate determination of concentration of immunoglobulin (IgG) to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, immune competence in individual patients and to measure the prevalence of immunity in populations. Surface modified polyacrylonitrile (PAN) fibers were evaluated as a matrix to develop highly sensitive method for the detection of anti-tetanus antibody in a sandwich ELISA format. In the proposed method tetanus toxoid immobilized on modified PAN fibers was used to detect anti-tetanus antibody (raised in horse hence represented as horse anti-tetanus toxoid or HAT-Ab) with horse raddish peroxidase enzyme conjugated with Rabbit anti-Horse IgG (RAH-HRP) as the label within 2.5h. A sigmoidal pattern for the detection of different concentration of antibody ranging from 1.0 to 0.0001 IU mL(-1) was validated. The immunoassay recorded a very high sensitivity as concentration as low as 0.0005 IU mL(-1) of HAT-Ab was detected. The intra- and inter-assay precision for 3 parallel measurements of 0.01 and for 0.001 IU mL(-1) of antibody varied from 5.4% to 11% and 5.7% to 20% respectively. PAN fibers were also used to qualitatively access the presence of different level of anti-tetanus antibody spiked in human blood. Seroepidemiological studies to measure the immunity against tetanus were conducted with twenty-five human beings belonging to various age groups using modified PAN-ELISA. The sensitivity, specificity and the reproducibility of the developed immunoassay indicate the potential application of modified PAN fibers in the field of immunodiagnostics. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. An ELISA test for the detection of antibodies to Legionella pneumophila.

    OpenAIRE

    Wreghitt, T G; Nagington, J; Gray, J

    1982-01-01

    An enzyme-linked immunosorbent assay (ELISA) test has been developed to detect antibodies to Legionella pneumophila serogroup 1. There is good correlation between indirect fluorescent antibody (IFA) and ELISA titres but ELISA is more sensitive.

  8. Anti-Trypanosoma cruzi antibody detection in eastern Andalusia (Spain).

    Science.gov (United States)

    Marín, Clotilde; Concha-Valdez, Fanny; Cañas, Rocío; Gutiérrez-Sánchez, Ramón; Sánchez-Moreno, Manuel

    2014-03-01

    Chagas disease caused by the protozoan haemoflagellate Trypanosoma cruzi is no longer found exclusively in Latin America; the disease is occurring in Europe, and Spain is the country with the highest prevalence. Our aim was to detect anti-T. cruzi antibodies in blood donors from southeast Spain, and we performed eight serological diagnostic assays on each of 550 blood samples collected in March-June 2010. Two in-house ELISA methods were used to test against a parasite lysate (ELISA-H) and the semi-purified superoxide dismutase excreted by T. cruzi (ELISA-SODe); we also used the Western blot technique against the same antigen (WB-SODe), indirect immunofluorescence (IFA) and four commercial tests. The serological test results showed a range of seroprevalence values, the lowest being 1.1%, determined by IFA and two commercial tests (Ab rapid and Chagascreen); other values were: 1.3% (commercial ELISA [Chagas ELISA IgG+IgM]); 2.1% (immunochromatographic test [Stick Chagas]); 2.7% (ELISA-H); 4.0% (WB-SODe); and 4.2%, the highest value (ELISA-SODe). The excellent specificity of SODe antigen for the detection of antibodies to T. cruzi in donors lead us to affirm that the serological test performed with this biomarker could provide a useful screening and confirmatory test method for cases of Chagas disease.

  9. Multifunctional Dendrimer-templated Antibody Presentation on Biosensor Surfaces for Improved Biomarker Detection.

    Science.gov (United States)

    Han, Hye Jung; Kannan, Rangaramanujam M; Wang, Sunxi; Mao, Guangzhao; Kusanovic, Juan Pedro; Romero, Roberto

    2010-02-08

    Dendrimers, with their well-defined globular shape and a high density of functional groups, are ideal nanoscale materials for templating sensor surfaces. This work exploits dendrimers as a versatile platform for capturing biomarkers with improved sensitivity and specificity. Synthesis, characterization, fabrication, and functional validation of the dendrimer-based assay platform are described. Bifunctional hydroxyl/thiol functionalized G4-polyamidoamine (PAMAM) dendrimer is synthesized and immobilized on to the polyethylene-glycol (PEG)-functionalized assay plate by coupling PEG-maleimide and dendrimer thiol groups. Simultaneously, part of the dendrimer thiol groups are converted to hydrazide functionalities. The resulting dendrimer-modified surface is coupled to the capture antibody in the Fc region of the oxidized antibody. This preserves the orientation flexibility of the antigen binding region (Fv) of the antibody. To validate the approach, the fabricated plates are further used as a solid phase for developing a sandwich type ELISA to detect IL-6 and IL-1β, important biomarkers for early stages of chorioamnionitis. The dendrimer-modified plate provides assays with significantly enhanced sensitivity, lower nonspecific adsorption, and a detection limit of 0.13 pg ml -1 for IL-6 luminol detection and 1.15 pg ml -1 for IL-1β TMB detection, which are significantly better than those for the traditional ELISA. The assays were validated in human serum samples from normal (non-pregnant) woman and pregnant women with pyelonephritis. The specificity and the improved sensitivity of the dendrimer-based capture strategy could have significant implications for the detection of a wide range of cytokines and biomarkers since the capture strategy could be applied to multiplex microbead assays, conductometric immunosensors and field effect biosensors.

  10. Towards a peptide-based suspension array for the detection of pestivirus antibodies in swine.

    Science.gov (United States)

    van der Wal, Fimme J; Jelsma, Tinka; Fijten, Helmi; Achterberg, René P; Loeffen, Willie L A

    2016-09-01

    Classical swine fever (CSF) is a highly contagious and lethal disease in swine. Serological tests for the diagnosis of CSF need not only to detect antibodies against CSFV, but also need to differentiate these from antibodies against other pestiviruses. To investigate the possibilities of specific peptide-based serology, various synthetic peptides that represent a well-described linear epitope of the CSFV E2 protein (TAVSPTTLR) were used to test the viability of a peptide-based suspension array for the detection of antibodies against pestiviruses in swine. The results show that N-terminally biotinylated peptides can bind to avidin conjugated beads, and function in detection of the corresponding monoclonal antibody WH303. There are indications that the length of the spacer between epitope and biotin affect the efficiency of the peptide-antibody interaction. A protocol was established that enables probing for antibodies in porcine sera, where neutravidin-blocking of serum and the use of empty control beads for normalization was crucial. With a set of porcine sera with antibodies against various pestiviruses, the proof of concept of a peptide-based suspension array for specific detection of antibodies against pestiviruses in porcine sera was demonstrated. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Iodine-131 labeled anti-CEA polyclonal antibody detection of gastrointestinal cancer

    International Nuclear Information System (INIS)

    Nabi, H.A.; Hinkle, G.H.; Olsen, J.O.; Haagensen, D.A.; Thurston, M.O.; Mojzisik, C.; Houchens, D.; Martin, E.W. Jr.

    1984-01-01

    To localize gastrointestinal tumor, 31 patients were injected with 1.7-2.1 mCi I-131 anti-CEA baboon polyclonal antibody. Whole body imaging at 48, 72, and occasionally 96 hrs was performed with a Signa Camera (Technicare) peaked at 364 keV with 20% window. Additional spot views were usually obtained. No subtraction methods were used. All patients had surgical and pathological confirmation of the nuclear medicine studies. Labeled antibody images were positive in 15 (8 recurrent or metastatic colorectal, 2 gastric, 1 pancreatic, 1 primary colon, and 1 breast metastatic to chest wall). In 1, antibody images were positive for metastatic deposits in para-aortic lymph nodes, but negative for primary rectal tumor. True negative images were observed in 6; false negative images in 9 (4 liver metastases, 2 rectal, 1 pancreatic, 1 mesenteric lymph node metastasis, 1 bone metastasis). In all cases, no correlation existed between preoperative CEA serum levels and imaging. I-131 labeled anti-CEA polyclonal antibody imaging proved highly efficient in detecting gastric cancer (2/2) and moderately efficient in detecting recurrent colorectal cancer (8/15). On the other hand, the I-131 labeled polyclonal anti-CEA antibody imaging was of limited value in detecting colon cancer (1/9), pancreatic cancer (1/4) and metastatic liver disease

  12. An ELISA to Detect Serum Antibodies to the Salivary Gland Toxin of Ixodes holocyclus Neumann in Dogs and Rodents

    Directory of Open Access Journals (Sweden)

    S. Hall-Mendelin

    2011-01-01

    Full Text Available The Ixodes holocyclus tick causes paralysis in up to 10,000 companion and domestic animals each year in Australia. Treatment requires the removal of the parasite and the administration of a commercial tick antiserum that is prepared from hyperimmune dogs. Each batch of this serum is initially tested for toxin-neutralising potency in a mouse bioassay that is expensive, time consuming, and subjective. With the aim of developing a rapid in vitro assay to replace the bioassay, we used a partially purified antigen prepared from I. holocyclus salivary glands to develop an ELISA to detect toxin-reactive antibodies in hyperimmune dog sera. The optimised ELISA reliably detected antibodies reactive to I. holocyclus salivary gland antigens. Parallel testing of sera with a negative control antigen prepared from the salivary glands of the nontoxic tick Rhipicephalus (Boophilus microplus provided further evidence that we were detecting toxin-specific antibodies in the assay. Using the ELISA, we could also detect antibodies induced in rats after experimental infestation with I. holocyclus. This assay shows promise as an alternative means of assessing the potency of batches of hyperimmune dog serum and to screen for toxin-reactive monoclonal antibodies produced from immunised rodents.

  13. Optimization of a method for the detection of immunopotentiating antibodies against serotype 1 of dengue virus

    International Nuclear Information System (INIS)

    Soto Garita, Claudio

    2014-01-01

    An immunopotentiation trial has used sera from dengue seropositive patients from Costa Rica's endemic areas. The detection and semi-quantification of immunopotentiating antibodies were optimized against dengue virus serotype 1. The cell line K562 (human erythromyeloblastoid leukemia cells) has been more efficient than the U937 (human histiocytic lymphoma cells). A more adequate detection of immunopotentiating antibodies was determined. The optimal infection and virus-antibody incubation parameters are demonstrated for the detection of immunopotentiating antibodies with the immunostaining technique. The immuno-optimized assay has allowed the detection and semi-quantification of immunopotentiating antibodies against serotype 1 of dengue virus. Samples of strong positive, weak positive and dengue negative sera are analyzed. The end has been to evaluate the usefulness in the detection and semi-quantification of immunopotentiating antibodies. The presence of immunopotentiating antibodies was demonstrated against dengue virus serotype 1 in endemic zones of Costa Rica, to complement with the evaluation of the other existing serotypes is recommended [es

  14. Detection of LGI1 and CASPR2 antibodies with a commercial cell-based assay in patients with very high VGKC-complex antibody levels.

    Science.gov (United States)

    Yeo, T; Chen, Z; Chai, J Y H; Tan, K

    2017-07-15

    The presence of VGKC-complex antibodies, without LGI1/CASPR2 antibodies, as a standalone marker for neurological autoimmunity remains controversial. Additionally, the lack of an unequivocal VGKC-complex antibody cut-off level defining neurological autoimmunity makes it important to test for monospecific antibodies. We aim to determine the performance characteristics of a commercial assay (Euroimmun, Lübeck, Germany) for LGI1/CASPR2 antibody detection in patients with very high VGKC-complex antibody levels and report their clinico-serological associations. We identified 8 patients in our cohort with the highest VGKC-complex antibody levels (median 2663.5pM, range 933-6730pM) with VGKC-complex antibody related syndromes (Group A). Two other groups were identified; 1 group with suspected neuronal surface antibody syndromes and negative for VGKC-complex antibodies (Group B, n=8), and another group with cerebellar ataxia and negative for onconeuronal antibodies (Group C, n=8). Seven out of 8 patients (87.5%) in Group A had LGI1 and/or CASPR2 antibodies. One Group B patient had LGI1 antibodies but was negative on re-testing with a live cell assay. No Group C patients had monospecific antibodies. Inter-rater reliability was high; combining Groups A and B patients, the kappa statistic was 0.87 and 1.0 for LGI1 and CASPR2 antibodies respectively. We demonstrated that a high proportion of patients with very high VGKC-complex antibody levels and relevant clinical syndromes have LGI1 and/or CASPR2 antibodies detected by the commercial assay. Our findings lend support to the use of the assay for rapid and reliable detection of LGI1 and CASPR2 antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Biosensor technology for the detection of illegal drugs II: antibody development and detection techniques

    Science.gov (United States)

    Hilpert, Reinhold; Bauer, Christian; Binder, Florian; Grol, Michael; Hallermayer, Klaus; Josel, Hans-Peter; Klein, Christian; Maier, Josef; Makower, Alexander; Oberpriller, Helmut; Ritter, Josef

    1994-10-01

    In a joint project of Deutsche Aerospace, Boehringer Mannheim and the University of Potsdam portable devices for the detection of illegal drugs, based on biosensor technology, are being developed. The concept enrichment of the drug from the gas phase and detection by immunological means. This publication covers the development of specific antibodies and various detection procedures. Antibodies with a high affinity for cocaine have been developed with the aid of specially synthesized immunogens. A competitive detection procedure with biosensors based on optical grating couplers and applying particulate labels has been established, showing a lower detection limit of 10-10 mol/l for cocaine. Additionally, a combination of a displacement-immunoreactor and an enzymatically amplified electrode was investigated, which at present still suffers from insufficient sensitivity of the immunoreactor. An alternative, fleece-matrix based test procedure, where enrichment and detection steps are integrated in a single unit, is promising in terms of simplicity and sensitivity. A simple swab-test for the detection of cocaine at surfaces has been developed, which has a lower detection limit of about 10 ng and which can be performed within one minute.

  16. Anti sperm antibodies detection in infertile patients by radioimmunometry

    International Nuclear Information System (INIS)

    ELnabarawy, F.; Megahed, Y.M.; Tadrous, G.A.; Hamada, T.; Elbadry, A.

    1992-01-01

    Three different methods of testing for anti sperm antibodies were compared: complement cytotoxicity, sperm agglutination, and radiolabelled anti globulin antibody technique, for detection of anti sperm antibodies in serum and secretions (seminal plasma and cervical mucus). Sample from 120 patients with infertility were investigated by the previous three methods. The results of unexplained infertile patients revealed wide variations in figures, concerning the positivity of anti sperm antibody whether in their serum or secretions, by using the cytotoxicity or sperm agglutination tests. Using a specific radiolabelled anti globulin test, a subset of patients (44.9% in the serum of men and 50% in seminal plasma) with IgG anti sperm antibody was identified, and this antibody was present in 65.4% and 78,6% of infertile wives sera and cervical mucus, respectively. Therefore, this test has been used to identify and quantitate antibodies directed toward other human cell surfaces. It was concluded that this radiolabelled method is a clinically useful and a potentially versatile procedure that can be successfully applied to the diagnosis and management of patients with suspected immunologic infertility. 1 fig., 5 tab

  17. Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection

    Directory of Open Access Journals (Sweden)

    Christoph Gerber

    2013-04-01

    Full Text Available A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the biotinylated biomolecules, such as biotinylated bovine serum albumin (biotinylated BSA, forming a multilayer sensor for direct antibody capture. The cantilever biosensor has been successfully applied to the detection of mouse anti-BSA (m-IgG and sheep anti-BSA(s-IgG antibodies. As expected, the average differential surface stress signals of about 5.7 ± 0.8 ´ 10−3 N/m are very similar for BSA/m-IgG and BSA/s-IgG binding, i.e., they are independent of the origin of the antibody. A statistic evaluation of 112 response curves confirms that the multilayer protein cantilever biosensor shows high reproducibility. As a control test, a biotinylated maltose binding protein was used for detecting specificity of IgG, the result shows a signal of bBSA layer in response to antibody is 5.8 ´ 10−3 N/m compared to bMBP. The pre-functionalized biotin/PEG cantilever surface is found to show a long shelf-life of at least 40 days and retains its responsivity of above 70% of the signal when stored in PBS buffer at 4 °C. The protein cantilever biosensor represents a rapid, label-free, sensitive and reliable detection technique for a real-time protein assay.

  18. Detection of serum antitrichomonal antibodies in urogenital trichomoniasis by immunofluorescence.

    Directory of Open Access Journals (Sweden)

    Bhatt R

    1992-04-01

    Full Text Available Trichomonas vaginalis is a frequently encountered genital pathogen in both males and females. In females, vaginitis due to this parasite is one of the most common manifestation. The indirect fluorescent technique (IFA test was carried out to detect antitrichomonal antibodies in 370 female patients using whole cell antigen. Seventy one (19.18% gave positive reaction for either of the class IgG, IgM and IgA antibodies. The level of the IgG class antibodies was found to be higher i.e. 58 (81.69% than IgM 11 (15.27% antibodies, which may be suggestive of past infection or a prolonged manifestation by the organisms.

  19. Development of polyclonal antibodies for the detection of ...

    African Journals Online (AJOL)

    Development of polyclonal antibodies for the detection of recombinant human erythropoietin. Collares Thaís Farias, Monte Leonardo Garcia, Campos Vinicius Farias, Seixas Fabiana Kömmiling, Collares Tiago Veiras, Dellagostin Odir, Hartleben Cláudia Pinho ...

  20. A Model System for Concurrent Detection of Antigen and Antibody Based on Immunological Fluorescent Method

    Directory of Open Access Journals (Sweden)

    Yuan-Cheng Cao

    2015-01-01

    Full Text Available This paper describes a combined antigen/antibody immunoassay implemented in a 96-well plate using fluorescent spectroscopic method. First, goat anti-human IgG was used to capture human IgG (model antigen; goat anti-human IgG (Cy3 or FITC was used to detect the model antigen; a saturating level of model antigen was then added followed by unlabelled goat anti-human IgG (model antibody; finally, Cy3 labelled rabbit anti-goat IgG was used to detect the model antibody. Two approaches were applied to the concomitant assay to analyze the feasibility. The first approach applied FITC and Cy3 when both targets were present at the same time, resulting in 50 ng/mL of the antibody detection limit and 10 ng/mL of antigen detection limit in the quantitative measurements of target concentration, taking the consideration of FRET efficiency of 68% between donor and acceptor. The sequential approach tended to lower the signal/noise (S/N ratio and the detection of the model antigen (lower than 1 ng/mL had better sensitivity than the model antibody (lower than 50 ng/mL. This combined antigen/antibody method might be useful for combined detection of antigens and antibodies. It will be helpful to screen for both antigen and antibody particularly in the situations of the multiserotype and high-frequency mutant virus infections.

  1. A murine monoclonal antibody based enzyme-linked immunosorbent assay for almond (Prunus dulcis L.) detection.

    Science.gov (United States)

    Su, Mengna; Venkatachalam, Mahesh; Liu, Changqi; Zhang, Ying; Roux, Kenneth H; Sathe, Shridhar K

    2013-11-13

    A sandwich enzyme-linked immunosorbent assay (ELISA) using anti-almond soluble protein rabbit polyclonal antibodies as capture antibodies and murine monoclonal antibody 4C10 as the detection antibodies was developed. The assay is specific and sensitive (3-200 ng almond protein/mL) for almond detection. The standardized assay is accurate (assay variability assay did not register any cross-reactivity with the tested food matrices, suggesting the assay to be almond amandin specific. The assay could detect the presence of declared almond in the tested matched commercial samples. Further, the assay reliably detected the presence of almonds in the laboratory prepared food samples spiked with almond flour.

  2. Development of human antibody fragments using antibody phage display for the detection and diagnosis of Venezuelan equine encephalitis virus (VEEV

    Directory of Open Access Journals (Sweden)

    Hust Michael

    2008-09-01

    Full Text Available Abstract Background Venezuelan equine encephalitis virus (VEEV belongs to the Alphavirus group. Several species of this family are also pathogenic to humans and are recognized as potential agents of biological warfare and terrorism. The objective of this work was the generation of recombinant antibodies for the detection of VEEV after a potential bioterrorism assault or an natural outbreak of VEEV. Results In this work, human anti-VEEV single chain Fragments variable (scFv were isolated for the first time from a human naïve antibody gene library using optimized selection processes. In total eleven different scFvs were identified and their immunological specificity was assessed. The specific detection of the VEEV strains TC83, H12/93 and 230 by the selected antibody fragments was proved. Active as well as formalin inactivated virus particles were recognized by the selected antibody fragments which could be also used for Western blot analysis of VEEV proteins and immunohistochemistry of VEEV infected cells. The anti-VEEV scFv phage clones did not show any cross-reactivity with Alphavirus species of the Western equine encephalitis virus (WEEV and Eastern equine encephalitis virus (EEEV antigenic complex, nor did they react with Chikungunya virus (CHIKV, if they were used as detection reagent. Conclusion For the first time, this study describes the selection of antibodies against a human pathogenic virus from a human naïve scFv antibody gene library using complete, active virus particles as antigen. The broad and sensitive applicability of scFv-presenting phage for the immunological detection and diagnosis of Alphavirus species was demonstrated. The selected antibody fragments will improve the fast identification of VEEV in case of a biological warfare or terroristic attack or a natural outbreak.

  3. Anti-dog IgG secondary antibody successfully detects IgG in a variety of aquatic mammals

    Science.gov (United States)

    Roehl, Katherine; Jankowski, Mark D.; Hofmeister, Erik K.

    2016-01-01

    Serological tests play an important role in the detection of wildlife diseases. However, while there are many commercial assays and reagents available for domestic species, there is a need to develop efficient serological assays for wildlife. In recent years, marine mammals have represented a wildlife group with emerging infectious diseases, such as influenza, brucellosis, and leptospirosis. However, with the exception of disease-agent-specific assays or functional assays, few reports describe the use of antibody detection assays in marine mammals. In an indirect enzyme-linked immunoassay (EIA) or an immunofluorescence assay, antibody is detected using an antitarget species secondary conjugated antibody. The sensitivity of the assay depends on the avidity of the binding reaction between the bound antibody and the detection antibody. A commercial polyclonal antidog IgG conjugated antibody was tested in an EIA for its ability to sensitively detect the IgG of seven marine mammals including sea otter (Enhydra lutris), polar bear (Ursus maritimus), grey seal (Halichoerus grypus), harbor seal (Phoca vitulina), northern elephant seal (Mirounga angustirostris), California sea lion (Zalophus californianus), Pacific walrus (Odobenus rosmarus) and one freshwater mammal: Asian small-clawed otter (Aonyx cinerea). With the exception of Asian small-clawed sea otters, the detection of IgG in these marine mammals either exceeded or was nearly equal to detection of dog IgG. The use of the tested commercial antidog IgG antibody may be a valid approach to the detection of antibody response to disease in sea mammals.

  4. Detection of IgG antibodies against Bordetella pertussis with 125I-protein A

    International Nuclear Information System (INIS)

    Wirsing von Koenig, C.H.; Finger, H.

    1981-01-01

    A method for the detection of IgG antibodies against Bordetella pertussis is described, based on the principle of 'sandwich' radioimmunoassay. 125 I protein A is used as radioactive tracer. The influence of amounts of antigen, antibody, radioactive tracer, incubation time and temperature were tested and the optimal conditions for the assay are described. The procedure offers a simple, quick, and sensitive method for detecting antibodies against B. pertussis. Application and limitation of the test are discussed. (orig.)

  5. Microculture system for detection of Newcastle disease virus antibodies.

    Science.gov (United States)

    Wooley, R E; Brown, J; Gratzek, J B; Kleven, S H; Scott, T A

    1974-05-01

    A microculture system utilizing cytopathic effect (CPE) and hemadsorption (HAd) end points was effective in determining the level of Newcastle disease virus (NDV) antibodies. The microculture system was of comparable sensitivity to the plaque reduction test for the detection of NDV antibodies. The standards by which the CPE and HAd microculture tests would be considered reproducible were defined. The results indicate that the CPE and HAd microculture tests are reproducible within one twofold dilution.

  6. New tests to detect antiphospholipid antibodies: antiprothrombin (aPT) and anti-phosphatidylserine/prothrombin (aPS/PT) antibodies.

    Science.gov (United States)

    Sciascia, Savino; Khamashta, Munther A; Bertolaccini, Maria Laura

    2014-05-01

    Antiprothrombin antibodies have been proposed as potential new biomarkers for thrombosis and/or pregnancy morbidity in the setting of the antiphospholipid syndrome (APS). Antiprothrombin antibodies are commonly detected by ELISA, using prothrombin coated onto irradiated plates (aPT), or prothrombin in complex with phosphatidylserine (aPS/PT), as antigen. Although these antibodies can co-exist in the same patient, aPT and aPS/PT seem to belong to different populations of autoantibodies. Early research explored the role of antibodies to prothrombin as potential antigenic targets for the lupus anticoagulant (LA). To date their clinical significance is being investigated and their potential role in identifying patients at higher risk of developing thrombotic events or pregnancy morbidity is being probed.

  7. Detection of antibodies in neuropathy patients by synthetic GM1 mimics

    NARCIS (Netherlands)

    Pukin, A.; Jacobs, B.C.; Tio-Gillen, A.P.; Gilbert, M.; Endtz, H.P.; Belkum, van A.; Visser, G.M.; Zuilhof, H.

    2011-01-01

    Antibodies to the ganglioside GM1 are associated with various forms of acute and chronic immune-mediated neuropathy, including Guillain–Barré syndrome (GBS) and multifocal motor neuropathy. In diagnostics and research, these antibodies are usually detected by GM1 preparations derived from bovine

  8. Detection of anti-streptococcal, antienolase, and anti-neural antibodies in subjects with early-onset psychiatric disorders.

    Science.gov (United States)

    Nicolini, Humberto; López, Yaumara; Genis-Mendoza, Alma D; Manrique, Viana; Lopez-Canovas, Lilia; Niubo, Esperanza; Hernández, Lázaro; Bobes, María A; Riverón, Ana M; López-Casamichana, Mavil; Flores, Julio; Lanzagorta, Nuria; De la Fuente-Sandoval, Camilo; Santana, Daniel

    2015-01-01

    Infection with group A Streptococcus (StrepA) can cause post-infectious sequelae, including a spectrum of childhood-onset obsessive-compulsive (OCD) and tic disorders with autoimmune origin (PANDAS, Pediatric Autoimmune Neuropsychiatric Disorders Associated with Streptococcal Infections). Until now, no single immunological test has been designed that unequivocally diagnoses these disorders. In this study, we assessed the detection of serum antibodies against human brain enolase (AE), neural tissue (AN) and Streptococcus (AS) as a laboratory tool for the diagnosis of early-onset psychiatric disorders. Serum antibodies against human brain enolase, total brain proteins, and total proteins from StrepA were detected by ELISA in 37 patients with a presumptive diagnosis of PANDAS and in 12 healthy subjects from Mexico and Cuba. The antibody titers against human brain enolase (AE) and Streptococcal proteins (AS) were higher in patients than in control subjects (t-student, tAE=-2.17, P=0.035; tAS=-2.68, P=0.01, n=12 and 37/group, df=47, significance level 0.05), while the neural antibody titers did not differ between the two groups (P(t)=0.05). The number of subjects (titers> meancontrol + CI95) with simultaneous seropositivity to all three antibodies was higher in the patient group (51.4%) than in the control group (8.3%) group (X2=5.27, P=0.022, df=1, n=49). The simultaneous detection of all three of these antibodies could provide valuable information for the etiologic diagnosis of individuals with early-onset obsessive-compulsive disorders associated with streptococcal infection and, consequently, for prescribing suitable therapy.

  9. Evaluation of five hepatitis delta virus marker assays for detection of antigen and antibody.

    OpenAIRE

    Bezeaud, A; Rosenswajg, M; Guillin, M C

    1989-01-01

    Five commercially available assays for hepatitis delta (HD) virus markers were compared for sensitivity, specificity, and reproducibility: three assays for antibody (anti-HD), provided by Diagnostics Pasteur, Organon Teknika, and Abbott Laboratories, and two assays for antigen (HD Ag), from Pasteur and Organon Teknika. The assay from Organon Teknika is the less sensitive assay for anti-HD detection. Although the sensitivities of the Pasteur and Abbott assays for anti-HD detection are similar,...

  10. Development of electrochemical immunosensors based on different serum antibody immobilization methods for detection of Japanese encephalitis virus

    International Nuclear Information System (INIS)

    Tran, Quang Huy; Hanh Nguyen, Thi Hong; Phan, Thi Nga; Mai, Anh Tuan; Nguyen, Thi Thuy; Vu, Quang Khue

    2012-01-01

    This paper describes the development of electrochemical immunosensors based on human serum antibodies with different immobilization methods for detection of Japanese encephalitis virus (JEV). Human serum containing anti-JEV antibodies was used to immobilize onto the surface of silanized interdigitated electrodes by four methods: direct adsorption (APTES-serum), covalent binding with a cross linker of glutaraldehyde (APTES-GA-serum), covalent binding with a cross linker of glutaraldehyde combined with anti-human IgG (APTES-GA-anti-HIgG-serum) and covalent binding with a cross linker of glutaraldehyde combined with a bioaffinity of protein A (APTES-GA-PrA-serum). Atomic force microscopy was used to verify surface characteristics of the interdigitated electrodes before and after treatment with serum antibodies. The output signal of the immunosensors was measured by the change of conductivity resulting from the specific binding of JEV antigens and serum antibodies immobilized on the electrodes, with the help of horseradish peroxidase (HRP)-labeled secondary antibody against JEV. The results showed that the APTES-GA-PrA-serum method provided the highest signal of the electrochemical immunosensor for detection of JEV antigens, with the linear range from 25 ng ml −1 to 1 μg ml −1 , and the limit of detection was about 10 ng ml −1 . This study shows a potential development of novel electrochemical immunosensors applied for virus detection in clinical samples in case of possible outbreaks

  11. Comparison of radioimmunoassay and ELISA methods for detection of antibodies to chromatin components

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, E; Cheng, N [North Carolina Univ., Chapel Hill (USA). Dept. of Bacteriology and Immunology

    1983-09-16

    A solid phase radioimmunoassay has been compared with an enzyme-linked immunosorbent assay (ELISA) for efficacy in measuring anti-chromatin antibodies. The low backgrounds achieved with the radioimmunoassay method produced a high signal-to-noise ratio and enabled detection of the human test antiserum at a dilution of 1:102,400. By contrast, the ELISA could detect the same antiserum only at a dilution of 1;3200 and above. The radioimmunoassay was consistently more sensitive than the ELSIA for detection of anti-chromatin antibodies in a number of human and mouse sera and ascites fluid containing a monoclonal antibody. Factors affecting sensitivity in both assays are discussed.

  12. Specific antibodies to detect Tamarillo leaf malformation virus (TALMV) in Tamarillo

    International Nuclear Information System (INIS)

    Gallo Garcia, Yuliana; Marin Montoya, Mauricio; Gutierrez, Pablo Andres

    2011-01-01

    In Colombia, yields of Tamarillo are seriously affected by a complex viral disease known as virosis. This pathology was first reported in 1991 in the north of Antioquia and currently affects all Tamarillo growing regions in the country. Recent works have demonstrated the association of two potyviruses (potyviridae) with this disease: potato virus y (PVY) and Tamarillo leaf malformation virus (TALMV, proposed species). Specific diagnostic tools are required for early asymptomatic detection of these viruses and Tamarillo certification programs. In this study, we report the obtention of TALMV specific antibodies using a 15 residues peptide mimicking the n-terminal coat protein. Specificity and sensitivity of the anti-TALMV antibodies was determined by Elisa and dot-blot using recombinant protein and synthetic peptides as controls. The usefulness of these antibodies was validated from a preliminary trial of TALMV detection in plant samples obtained from Tamarillo crops in eastern Antioquia and results were compared with a TALMV specific coat RT-PCR detection protocol.

  13. Aqueous two-phase system patterning of detection antibody solutions for cross-reaction-free multiplex ELISA

    Science.gov (United States)

    Frampton, John P.; White, Joshua B.; Simon, Arlyne B.; Tsuei, Michael; Paczesny, Sophie; Takayama, Shuichi

    2014-05-01

    Accurate disease diagnosis, patient stratification and biomarker validation require the analysis of multiple biomarkers. This paper describes cross-reactivity-free multiplexing of enzyme-linked immunosorbent assays (ELISAs) using aqueous two-phase systems (ATPSs) to confine detection antibodies at specific locations in fully aqueous environments. Antibody cross-reactions are eliminated because the detection antibody solutions are co-localized only to corresponding surface-immobilized capture antibody spots. This multiplexing technique is validated using plasma samples from allogeneic bone marrow recipients. Patients with acute graft versus host disease (GVHD), a common and serious condition associated with allogeneic bone marrow transplantation, display higher mean concentrations for four multiplexed biomarkers (HGF, elafin, ST2 and TNFR1) relative to healthy donors and transplant patients without GVHD. The antibody co-localization capability of this technology is particularly useful when using inherently cross-reactive reagents such as polyclonal antibodies, although monoclonal antibody cross-reactivity can also be reduced. Because ATPS-ELISA adapts readily available antibody reagents, plate materials and detection instruments, it should be easily transferable into other research and clinical settings.

  14. Detection of antimycolic acid antibodies by liposomal biosensors

    CSIR Research Space (South Africa)

    Lemmer, Yolandy

    2009-01-01

    Full Text Available -mycolic acid antibodies by liposomal biosensors Running title: Antibody detection by liposomal biosensors Y. Lemmer1,3, S.T., Thanyani1, P.J. Vrey1, C.H.S. Driver2, L. Venter1, S. van Wyngaardt1, A.M.C. ten Bokum1, K.I. Ozoemena2, L.A. Pilcher2, D...H values. The anionic phosphatidyl residues (pKa ? 3.5) only become neutralised below pH 4, while the cationic state of choline (pKa = 13.9) is maintained over the full pH range measured (Tatulian et al., 1993). It is therefore expected that the stability...

  15. Detection of antisalivary duct antibody from Sjögren's syndrome by an autoradiographic method.

    Science.gov (United States)

    Cummings, N A; Tarpley, T M

    1978-01-01

    A new technique to detect anti-salivary duct antibody (ASDA) has been developed by using autoradiographic, rather than immunofluorescent methods. The antibody activity detected by autoradiography is probably classic ASDA. Both techniques may be consecutively performed on the same tissue section without attenuation of either. Some of the potential advantages of the radiolabelling of ASDA are pointed out, and a few preliminary experiments using the labelled antibody as a marker are presented.

  16. Detection of antibodies in human serum using trimellityl-erythrocytes: direct and indirect haemagglutination and haemolysis.

    Science.gov (United States)

    Turner, E S; Pruzansky, J J; Patterson, R; Zeiss, C R; Roberts, M

    1980-02-01

    Utilizing trimellityl-erythrocytes (TM-E), antibodies were detected in sera of seven workers with trimellitic anhydride (TMA) induced airway syndromes by direct haemagglutination, indirect haemagglutination with anti-human IgG, IgA or IgM or by haemolysis. Detectable levels of antibody were obtained with all three methods. The most sensitive technique was indirect haemagglutination using anti-IgG. When added as an inhibitor, TM-human serum albumin produced a 10- to 800-fold reduction in titres. TM-ovalbumin of similar epitope density was less inhibitory and sodium trimellitate the least inhibitory on a molar basis. All of the assays using haptenized human red cells were also capable of detecting anti-TM antibodies in Rhesus monkeys whose airways had been exposed to TMA. These assays are useful for detecting anti-TM antibodies and may also be adapted to demonstrate antibodies induced against other inhaled haptens in sera of environmentally exposed individuals or in animal models of such exposure.

  17. Clinical experience in humans with radiolabeled antibody for tumor detection

    International Nuclear Information System (INIS)

    Morrison, R.T.; Lyster, D.M.; Szasz, I.; Alcorn, L.N.; Huckell, V.F.; Rhodes, B.; Breslow, K.; Burchiel, S.

    1982-01-01

    I-131 and Tc-99m labeled polyclonal or monoclonal antibody and fragments of antibody, specific to human chorionic gonadotropin (hCG) or to a melanoma cell surface antigen (MCSA) were injected into proven cancer patients. Using standard homeostasis parameters, and scanning techniques, the safety and efficacy of each antibody was evaluated. Antibody fragments were expected to clear faster from the circulation allowing for earlier imaging and a better target-to-non-target ratio. The technetium label may perturb the antiboby's kinetics so that clearance is more rapid for both whole antibody and fragments. After a statistical evaluation of all parameters measured pre and post injection it was concluded that no acute toxicity reactions were present in any patient studied. Scan results were not acceptable for a tumor detecting procedure used in routine practice. Tumor upake was seen in less than 10% of scans

  18. Oriented antibodies as versatile detection element in biosensors

    NARCIS (Netherlands)

    Trilling, A.K.

    2013-01-01

    The aim of this thesis is to explore orientation of detection elements on biosensor

    surfaces. To this end, different strategies were combined such as surface chemistry and protein functionalization, with the aim to generate a platform for oriented immobilization of antibodies

    in

  19. Detection of deep venous thrombosis with indium 111-labelled monoclonal antibody against tissue plasminogen activator

    Energy Technology Data Exchange (ETDEWEB)

    Tromholt, N.; Hesse, B. (Hilleroed County Hospital (Denmark). Dept. of Clinical Physiology); Folkenborg, O. (Isotope-Pharmcy, Broenshoej (Denmark)); Selmer, J. (Novo Industri A/S, Bagsvaerd (Denmark)); Nielsen, N.T. (Hilleroed County Hospital (Denmark). Dept. of Radiology)

    1991-05-01

    The administration of a radiolabelled monoclonal antibody against tissue plasminogen activator allows detection of areas with increased fibrinolytic activity, i.e. those with an active thrombotic lesion. Eight patients with phlebographically verified deep venous thrombosis were examined. At the time of immunoscintigraphy study they were examined receiving anticoagulant therapy. Some 75-85 MBq {sup 111}In-labelled antibody were injected, and scintigrams were obtained after 30 min and after 24 h. The precise site of the thrombus could not be visualized after 30 min due to high background activity, whereas after 24 h it was detectable in all patients. The thrombus/background ratios achieved are twice as high as those observed in a human antifibrin antibody study. These preliminary data suggest a high sensitivity of our PA-specific antibody for the detection of active deep venous thrombosis in man, and our antibody seems to offer theoretical advantages over both platelet and fibrin-specific antibodies. (orig.).

  20. Detection of deep venous thrombosis with indium 111-labelled monoclonal antibody against tissue plasminogen activator

    International Nuclear Information System (INIS)

    Tromholt, N.; Hesse, B.; Selmer, J.; Nielsen, N.T.

    1991-01-01

    The administration of a radiolabelled monoclonal antibody against tissue plasminogen activator allows detection of areas with increased fibrinolytic activity, i.e. those with an active thrombotic lesion. Eight patients with phlebographically verified deep venous thrombosis were examined. At the time of immunoscintigraphy study they were examined receiving anticoagulant therapy. Some 75-85 MBq 111 In-labelled antibody were injected, and scintigrams were obtained after 30 min and after 24 h. The precise site of the thrombus could not be visualized after 30 min due to high background activity, whereas after 24 h it was detectable in all patients. The thrombus/background ratios achieved are twice as high as those observed in a human antifibrin antibody study. These preliminary data suggest a high sensitivity of our PA-specific antibody for the detection of active deep venous thrombosis in man, and our antibody seems to offer theoretical advantages over both platelet and fibrin-specific antibodies. (orig.)

  1. Diagnostic utility of egg yolk for the detection of avian metapneumovirus antibodies in laying hens.

    Science.gov (United States)

    Choi, Kang-Seuk; Lee, Eun-Kyoung; Jeon, Woo-Jin; Park, Mi-Ja; Yoo, Yae-Na; Kwon, Jun-Hun

    2010-12-01

    Surveillance and diagnosis of avian metapneumovirus (AMPV) infection typically involve measurement of serum antibodies. In the current study, eggs instead of serum samples were used for the detection of AMPV antibodies in egg-laying chicken hens by enzyme-linked immunosorbent assay (ELISA). AMPV-free commercial layer hens were experimentally challenged with AMPV strain SC1509 through intravenous or oculonasal administration. Antibody levels were determined by ELISA. AMPV antibodies were detected in egg yolks from challenged hens by 7 days postinoculation (dpi), with the peak titer at 16 dpi. Antibody levels in eggs laid at 28 dpi correlated well (r = 0.93) with sera taken 28 dpi from the same hens. In a field trial of the yolk ELISA, six broiler breeder farms were surveyed, and all tested positive for AMPV antibodies in hen eggs, although positivity varied from farm to farm. Abnormal discolored eggs collected from outbreak farms had significantly higher titers of AMPV yolk antibodies than normal eggs from the same farm, unlike clinically healthy farms, where normal and abnormal eggs had similar antibody titers. These results indicate that diagnosis of AMPV infection by yolk ELISA to detect anti-AMPV antibodies may be a suitable alternative to serologic testing.

  2. Domestic cat microsphere immunoassays: detection of antibodies during feline immunodeficiency virus infection.

    Science.gov (United States)

    Wood, Britta A; Carver, Scott; Troyer, Ryan M; Elder, John H; VandeWoude, Sue

    2013-10-31

    Microsphere immunoassays (MIAs) allow rapid and accurate evaluation of multiple analytes simultaneously within a biological sample. Here we describe the development and validation of domestic cat-specific MIAs for a) the quantification of total IgG and IgA levels in plasma, and b) the detection of IgG and IgA antibodies to feline immunodeficiency virus (FIV) capsid (CA) and surface (SU) proteins, and feline CD134 in plasma. These assays were used to examine the temporal antibody response of domestic cats infected with apathogenic and pathogenic FIVs, and domestic cats infected with parental and chimeric FIVs of varying pathogenicity. The results from these studies demonstrated that a) total IgG antibodies increase over time after infection; b) α-CA and α-SU IgG antibodies are detectable between 9 and 28 days post-infection and increase over time, and these antibodies combined represent a fraction (1.8 to 21.8%) of the total IgG increase due to infection; c) measurable α-CD134 IgG antibody levels vary among individuals and over time, and are not strongly correlated with viral load; d) circulating IgA antibodies, in general, do not increase during the early stage of infection; and e) total IgG, and α-CA and α-SU IgG antibody kinetics and levels vary with FIV viral strain/pathogenicity. The MIAs described here could be used to screen domestic cats for FIV infection, and to evaluate the FIV-specific or total antibody response elicited by various FIV strains/other diseases. © 2013.

  3. Immuno-Northern Blotting: Detection of RNA Modifications by Using Antibodies against Modified Nucleosides.

    Directory of Open Access Journals (Sweden)

    Eikan Mishima

    Full Text Available The biological roles of RNA modifications are still largely not understood. Thus, developing a method for detecting RNA modifications is important for further clarification. We developed a method for detecting RNA modifications called immuno-northern blotting (INB analysis and herein introduce its various capabilities. This method involves the separation of RNAs using either polyacrylamide or agarose gel electrophoresis, followed by transfer onto a nylon membrane and subsequent immunoblotting using antibodies against modified nucleosides for the detection of specific modifications. We confirmed that INB with the antibodies for 1-methyladenosine (m1A, N6-methyladenosine (m6A, pseudouridine, and 5-methylcytidine (m5C showed different modifications in a variety of RNAs from various species and organelles. INB with the anti-m5C antibody revealed that the antibody cross-reacted with another modification on DNA, suggesting the application of this method for characterization of the antibody for modified nucleosides. Additionally, using INB with the antibody for m1A, which is a highly specific modification in eukaryotic tRNA, we detected tRNA-derived fragments known as tiRNAs under the cellular stress response, suggesting the application for tracking target RNA containing specific modifications. INB with the anti-m6A antibody confirmed the demethylation of m6A by the specific demethylases fat mass and obesity-associated protein (FTO and ALKBH5, suggesting its application for quantifying target modifications in separated RNAs. Furthermore, INB demonstrated that the knockdown of FTO and ALKBH5 increased the m6A modification in small RNAs as well as in mRNA. The INB method has high specificity, sensitivity, and quantitative capability, and it can be employed with conventional experimental apparatus. Therefore, this method would be useful for research on RNA modifications and metabolism.

  4. Immuno-Northern Blotting: Detection of RNA Modifications by Using Antibodies against Modified Nucleosides.

    Science.gov (United States)

    Mishima, Eikan; Jinno, Daisuke; Akiyama, Yasutoshi; Itoh, Kunihiko; Nankumo, Shinnosuke; Shima, Hisato; Kikuchi, Koichi; Takeuchi, Yoichi; Elkordy, Alaa; Suzuki, Takehiro; Niizuma, Kuniyasu; Ito, Sadayoshi; Tomioka, Yoshihisa; Abe, Takaaki

    2015-01-01

    The biological roles of RNA modifications are still largely not understood. Thus, developing a method for detecting RNA modifications is important for further clarification. We developed a method for detecting RNA modifications called immuno-northern blotting (INB) analysis and herein introduce its various capabilities. This method involves the separation of RNAs using either polyacrylamide or agarose gel electrophoresis, followed by transfer onto a nylon membrane and subsequent immunoblotting using antibodies against modified nucleosides for the detection of specific modifications. We confirmed that INB with the antibodies for 1-methyladenosine (m1A), N6-methyladenosine (m6A), pseudouridine, and 5-methylcytidine (m5C) showed different modifications in a variety of RNAs from various species and organelles. INB with the anti-m5C antibody revealed that the antibody cross-reacted with another modification on DNA, suggesting the application of this method for characterization of the antibody for modified nucleosides. Additionally, using INB with the antibody for m1A, which is a highly specific modification in eukaryotic tRNA, we detected tRNA-derived fragments known as tiRNAs under the cellular stress response, suggesting the application for tracking target RNA containing specific modifications. INB with the anti-m6A antibody confirmed the demethylation of m6A by the specific demethylases fat mass and obesity-associated protein (FTO) and ALKBH5, suggesting its application for quantifying target modifications in separated RNAs. Furthermore, INB demonstrated that the knockdown of FTO and ALKBH5 increased the m6A modification in small RNAs as well as in mRNA. The INB method has high specificity, sensitivity, and quantitative capability, and it can be employed with conventional experimental apparatus. Therefore, this method would be useful for research on RNA modifications and metabolism.

  5. Radiolabeled antibody in the detection of infection using endocarditis as a model

    International Nuclear Information System (INIS)

    Mishkin, F.S.; Wong, D.W.; Dhawan, V.K.; Reese, I.C.; Thadepalli, H.

    1983-01-01

    The authors have examined a method to detect infections using radiolabeled antibodies. Staphylococcal endocarditis was chosen as a model because it poses a common clinical diagnostic problem. The experiments demonstrate that biologically active antibodies may be extracted and efficiently labeled by a relatively simple process. This has the potential to make the specificity of the in vivo antigen-antibody reaction available through the use of autologously extracted, labeled γ-globulin

  6. Ma2 antibodies: an evaluation of commercially available detection methods.

    Science.gov (United States)

    Johannis, Wibke; Renno, Joerg H; Wielckens, Klaus; Voltz, Raymond

    2011-01-01

    Ma2 antibodies belong to the onconeuronal antibodies which define a "definite" paraneoplastic neurological syndrome (PNS). Because of the clinical relevance, use of two separate methods (indirect immunofluorescence technique--IFT--and immunoblot) is advocated; however, with an increasing number of commercially available assay systems, usually only one assay is performed. We compared IFT and three commercially available immunoblots (ravo Diagnostika, Euroimmun, Milenia Biotec) on sera from 35 patients with clinically suspected PNS. 17 were Ma2 antibody associated as defined by consensus result (showing positive reactivity in 2 assays), 18 were Ma2 antibody negative controls. Sensitivity/specificity for single assays were for IFT 94%/94%, for ravo Diagnostika PNS blot 88%/100%, for Euroimmun Neuronal Antigens Profile blot 100%/89%, and for Milenia Biotec MTR blot 94%/100%. Our data confirm, although all tests performed well, a combination of 2 independent assays is still advisable for Ma2 antibody detection in order to achieve higher sensitivity and specificity rates.

  7. Detection systems for antibody responses against herpes B virus

    OpenAIRE

    Pöhlmann, Stefan; Krüger, Astrid; Hafezi, Wali; Schneider, Stefan; Gruber, Jens; Winkler, Michael; Kaul, Artur

    2017-01-01

    Herpes B virus (BV) infection is highly prevalent among adult Asian macaques and rarely causes severe disease in infected animals. In contrast, BV infection of humans can induce fatal encephalitis in the absence of treatment. Therefore, the development of diagnostic tests for specific and sensitive detection of antibodies against BV is an important task. The cross-reactivity of antibodies against BV with related simplex viruses of other primates may afford an opportunity to ...

  8. Effective antibodies immobilization and functionalized nanoparticles in a quartz-crystal microbalance-based immunosensor for the detection of parathion.

    Directory of Open Access Journals (Sweden)

    Bartolomeo Della Ventura

    Full Text Available Biosensor-based detection provides a rapid and low-cost alternative to conventional analytical methods for revealing the presence of the contaminants in water as well as solid matrices. Although important to be detected, small analytes (few hundreds of Daltons are an issue in biosensing since the signal they induce in the transducer, and specifically in a Quartz-Crystal Microbalance, is undetectable. A pesticide like parathion (M = 292 Da is a typical example of contaminant for which a signal amplification procedure is desirable.The ballasting of the analyte by gold nanoparticles has been already applied to heavy target as proteins or bacteria to improve the limit of detection. In this paper, we extend the application of such a method to small analytes by showing that once the working surface of a Quartz-Crystal Microbalance (QCM has been properly functionalized, a limit of detection lower than 1 ppb is reached for parathion. The effective surface functionalization is achieved by immobilizing antibodies upright oriented on the QCM gold surface by a simple photochemical technique (Photonic Immobilization Technique, PIT based on the UV irradiation of the antibodies, whereas a simple protocol provided by the manufacturer is applied to functionalize the gold nanoparticles. Thus, in a non-competitive approach, the small analyte is made detectable by weighing it down through a "sandwich protocol" with a second antibody tethered to heavy gold nanoparticles. The immunosensor has been proved to be effective against the parathion while showing no cross reaction when a mixture of compounds very similar to parathion is analyzed.The immunosensor described in this paper can be easily applied to any small molecule for which polyclonal antibodies are available since both the functionalization procedure of the QCM probe surface and gold nanoparticle can be applied to any IgG, thereby making our device of general application in terms of target analyte.

  9. Development of a sensitive and specific epitope-blocking ELISA for universal detection of antibodies to human enterovirus 71 strains.

    Directory of Open Access Journals (Sweden)

    Fang He

    Full Text Available BACKGROUND: Human Enterovirus 71 (EV71 is a common cause of hand, foot and mouth disease (HFMD in young children. It is often associated with severe neurological diseases and mortalities in recent outbreaks across the Asia Pacific region. Currently, there is no efficient universal antibody test available to detect EV71 infections. METHODOLOGY/PRINCIPAL FINDING: In the present study, an epitope-blocking ELISA was developed to detect specific antibodies to human EV71 viruses in human or animal sera. The assay relies on a novel monoclonal antibody (Mab 1C6 that specifically binds to capsid proteins in whole EV71 viruses without any cross reaction to any EV71 capsid protein expressed alone. The sensitivity and specificity of the epitope-blocking ELISA for EV71 was evaluated and compared to microneutralization using immunized animal sera to multiple virus genotypes of EV71 and coxsackieviruses. Further, 200 serum sample from human individuals who were potentially infected with EV71 viruses were tested in both the blocking ELISA and microneutralization. Results indicated that antibodies to EV71 were readily detected in immunized animals or human sera by the epitope blocking ELISA whereas specimens with antibodies to other enteroviruses yielded negative results. This assay is not only simpler to perform but also shows higher sensitivity and specificity as compared to microneutralization. CONCLUSION: The epitope-blocking ELISA based on a unique Mab 1C6 provided highly sensitive and 100% specific detection of antibodies to human EV71 viruses in human sera.

  10. Stochastic simulation modeling to determine time to detect Bovine Viral Diarrhea antibodies in bulk tank milk

    DEFF Research Database (Denmark)

    Foddai, Alessandro; Enøe, Claes; Krogh, Kaspar

    2014-01-01

    A stochastic simulation model was developed to estimate the time from introduction ofBovine Viral Diarrhea Virus (BVDV) in a herd to detection of antibodies in bulk tank milk(BTM) samples using three ELISAs. We assumed that antibodies could be detected, after afixed threshold prevalence of seroco......A stochastic simulation model was developed to estimate the time from introduction ofBovine Viral Diarrhea Virus (BVDV) in a herd to detection of antibodies in bulk tank milk(BTM) samples using three ELISAs. We assumed that antibodies could be detected, after afixed threshold prevalence......, which was the most efficient ELISA, could detect antibodiesin the BTM of a large herd 280 days (95% prediction interval: 218; 568) after a transientlyinfected (TI) milking cow has been introduced into the herd. The estimated time to detectionafter introduction of one PI calf was 111 days (44; 605...

  11. Detection of thrombi using a Tc-99m labelled antifibrin monoclonal antibody (MoAb)

    International Nuclear Information System (INIS)

    Wasser, M.N.J.M.

    1989-01-01

    This thesis presents an investigation into the possibility of immunoscintigraphic detection of thrombi using an antifibrin monoclonal antibody, and fragments of the latter. The antifibrin antibody and tis fragments were labelled with Ec-99m, which has excellent characteristics for imaging with a gamma camera. The characterization of the antifibrin antibody and its fragments, the assessment of quality of labelling with Tc-99m, and results of experiments in vitro and in animals, which show the potential of immunoscintigraphic detection, are described. (author). 142 refs.; 44 figs.; 5 tabs

  12. Development of rabbit monoclonal antibodies for detection of alpha-dystroglycan in normal and dystrophic tissue.

    Directory of Open Access Journals (Sweden)

    Marisa J Fortunato

    Full Text Available Alpha-dystroglycan requires a rare O-mannose glycan modification to form its binding epitope for extracellular matrix proteins such as laminin. This functional glycan is disrupted in a cohort of muscular dystrophies, the secondary dystroglycanopathies, and is abnormal in some metastatic cancers. The most commonly used reagent for detection of alpha-dystroglycan is mouse monoclonal antibody IIH6, but it requires the functional O-mannose structure for recognition. Therefore, the ability to detect alpha-dystroglycan protein in disease states where it lacks the full O-mannose glycan has been limited. To overcome this hurdle, rabbit monoclonal antibodies against the alpha-dystroglycan C-terminus were generated. The new antibodies, named 5-2, 29-5, and 45-3, detect alpha-dystroglycan from mouse, rat and pig skeletal muscle by Western blot and immunofluorescence. In a mouse model of fukutin-deficient dystroglycanopathy, all antibodies detected low molecular weight alpha-dystroglycan in disease samples demonstrating a loss of functional glycosylation. Alternately, in a porcine model of Becker muscular dystrophy, relative abundance of alpha-dystroglycan was decreased, consistent with a reduction in expression of the dystrophin-glycoprotein complex in affected muscle. Therefore, these new rabbit monoclonal antibodies are suitable reagents for alpha-dystroglycan core protein detection and will enhance dystroglycan-related studies.

  13. Development and evaluation of an anti-rabies virus phosphoprotein-specific monoclonal antibody for detection of rabies neutralizing antibodies using RFFIT.

    Science.gov (United States)

    Um, Jihye; Chun, Byung Chul; Lee, Yeong Seon; Hwang, Kyu Jam; Yang, Dong-Kun; Park, Jun-Sun; Kim, Su Yeon

    2017-12-01

    Rabies is a major public health problem with a fatality rate close to 100%; however, complete prevention can be achieved through pre- or post-exposure prophylaxis. The rapid fluorescent focus inhibition test (RFFIT) is one of the recommended testing methods to determine the production of neutralizing antibodies after vaccination. Here, we report the development of a new monoclonal antibody (mAb) designed to react specifically with Rabies virus (RABV) phosphoprotein (P protein), and the evaluation of its applicability to the RFFIT and its effectiveness as a diagnostic reagent for human rabies. The mAb KGH P 16B8 was produced to target the P protein of the Korean KGH RABV strain. An indirect immunofluorescence assay (IFA) was conducted to detect various strains of RABV in various cell lines. Alexa-conjugated KGH P 16B8 (16B8-Alexa) was developed for the RFFIT. The IFA test could detect RABV up to a 1:2,500 dilution, with a detection limit comparable to that of a commercial diagnostic reagent. The sensitivity, specificity, positive predictive value, and negative predictive value of the RFFIT using 16B8-Alexa in 414 clinical specimens were 98.67%, 99.47%, 99.55%, and 98.42%, respectively. The results of the RFFIT with 16B8-Alexa were strongly correlated with those obtained using an existing commercial diagnostic reagent (r = 0.995, prabies neutralizing antibody titer and establish a diagnosis in human. Thus, 16B8-Alexa is expected to serve as an alternative diagnostic reagent that is widely accessible, with potentially broad applications beyond those of the RFFIT in Korea. Further studies with 16B8-Alexa should provide insight into the immunological mechanism of the P protein of Korean RABV.

  14. Detection of HBs antigens and antibodies by immunoenzymology and radioimmunology. Comparison of the results

    International Nuclear Information System (INIS)

    Fauchet, R.; Genetet, B.; Phengsavath

    1981-01-01

    The respective sensitivity threshold of immunoenzymology and radioimmunology in HBs antigen and antibody detection were compared and the optical density (o.d.) and counts per minute (cpm) values were correlated with the concentration in ng/ml of a given sample. The sensitivity comparison between RIA and EIA appears in favour of the former technique for both HBs antigen and HBs antibody detection. However the procedure tried here to detect HBs antibodies by immunoenzymology is simple, requires only the choice of neutralising antigenic pool and sensitivity threshold and could usefully be generalized for teams not authorized to handle radioelements. Quantification of the HBs antigen content in ng/ml is a difficult operation, needing great care in the dilution of the sera tested. The reproducibility is not perfect. The semi-quantitative RIA determination expressed in R.U. (radioimmunological units) seems adequate as a mean to follow the progress of an HBs antibody in both liver disease and vaccination [fr

  15. Chemo-enzymatic production of O-glycopeptides for the detection of serum glycopeptide antibodies

    DEFF Research Database (Denmark)

    Nøstdal, Alexander; Wandall, Hans H

    2013-01-01

    Protein microarray is a highly sensitive tool for antibody detection in serum. Monitoring of patients' antibody titers to specific antigens is increasingly employed in the diagnosis of several conditions, ranging from infectious diseases, allergies, autoimmune diseases, and cancer. In this protoc...

  16. Selectivity verification of cardiac troponin monoclonal antibodies for cardiac troponin detection by using conventional ELISA

    Science.gov (United States)

    Fathil, M. F. M.; Arshad, M. K. Md; Gopinath, Subash C. B.; Adzhri, R.; Ruslinda, A. R.; Hashim, U.

    2017-03-01

    This paper presents preparation and characterization of conventional enzyme-linked immunosorbent assay (ELISA) for cardiac troponin detection to determine the selectivity of the cardiac troponin monoclonal antibodies. Monoclonal antibodies, used to capture and bind the targets in this experiment, are cTnI monoclonal antibody (MAb-cTnI) and cTnT monoclonal antibody (MAb-cTnT), while both cardiac troponin I (cTnI) and T (cTnT) are used as targets. ELISA is performed inside two microtiter plates for MAb-cTnI and MAb-cTnT. For each plate, monoclonal antibodies are tested by various concentrations of cTnI and cTnT ranging from 0-6400 µg/l. The binding selectivity and level of detection between monoclonal antibodies and antigen are determined through visual observation based on the color change inside each well on the plate. ELISA reader is further used to quantitatively measured the optical density of the color changes, thus produced more accurate reading. The results from this experiment are utilized to justify the use of these monoclonal antibodies as bio-receptors for cardiac troponin detection by using field-effect transistor (FET)-based biosensors coupled with substrate-gate in the future.

  17. An improved autoradiographic technique for the detection of antibody-forming cells

    International Nuclear Information System (INIS)

    Mason, D.W.

    1976-01-01

    An autoradiographic technique for the detection of antibody-forming cells has been developed for the assay of anti-DNP responses. The lymphoid cell suspension to be assayed was allowed to sediment on to a glass slide coated with DNP-conjugated gelatin to which the secreted antibody bound during subsequent incubation. The bound antibody and its Ig class was revealed by a second incubation using 125 I-anti-immunoglobulin reagents followed by autoradiography. Studies on the sensitivity and specificity of the method are presented and its advantages over other techniques described. The technique should be readily applicable to other haptens

  18. Oligopeptide-based enzyme immunoassay for ovine lentivirus antibody detection.

    OpenAIRE

    Kwang, J; Torres, J V

    1994-01-01

    Ovine progressive pneumonia virus (OPPV) is a lentivirus which causes a progressive disease in sheep. Immunodominant epitopes have been identified in the envelope gp40 glycoprotein. Synthetic peptides representing these regions are able to detect the presence of OPPV antibodies in 96% of infected sheep.

  19. Amperometric biosensor based on a single antibody of dual function for rapid detection of Streptococcus agalactiae.

    Science.gov (United States)

    Vásquez, Gersson; Rey, Alba; Rivera, Camilo; Iregui, Carlos; Orozco, Jahir

    2017-01-15

    Pathogenic bacteria are responsible for several diseases in humans and in a variety of hosts. Detection of pathogenic bacteria is imperative to avoid and/or fight their potential harmful effects. This work reports on the first amperometric biosensor for the rapid detection of Streptococcus agalactiae (S. agalactiae). The biosensor relies on a single biotinylated antibody that immobilizes the bacteria on a screen-printed carbon electrode while is further linked to a streptavidin-conjugated HRP reporter. The biotinylated antibody provides selectivity to the biosensor whereas serves as an anchoring point to the reporter for further amplification of the electrochemical signal. The resultant immunosensor is simple, responds rapidly, and allows for the selective and highly sensitive quantification of S. agalactiae cells in a concentration range of 10 1 -10 7 CFUml -1 , with a detection limit of 10CFUml -1 . The approach not only enables a rapid detection and quantification of S. agalactiae in environmental samples but also opens up new opportunities for the simple fabrication of electrochemical immunosensors for different target pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Antimitochondrial antibodies and other antibodies in primary biliary cirrhosis: diagnostic and prognostic value.

    Science.gov (United States)

    Muratori, Luigi; Granito, Alessandro; Muratori, Paolo; Pappas, Georgios; Bianchi, Francesco B

    2008-05-01

    Antimitochondrial antibodies (AMA) are the serologic cornerstone in the diagnosis of primary biliary cirrhosis (PBC), even if they are not detectable in a proportion of patients, notwithstanding the most sensitive and sophisticated technologies used. To fill in the serologic gap in AMA-negative PBC, there is sound evidence to consider antinuclear antibody (ANA) patterns, such as anti-multiple nuclear dots and anti-membranous/rim-like, as PBC-specific surrogate hallmarks of the disease, and their detection can be considered virtually diagnostic. Furthermore, particular ANA specificities, such as anti-gp210, anti-p62, anticentromere antibodies, and anti-dsDNA, may provide additional diagnostic and prognostic information.

  1. Characterization of novel monoclonal antibodies against the MERS-coronavirus spike protein and their application in species-independent antibody detection by competitive ELISA.

    Science.gov (United States)

    Fukushi, Shuetsu; Fukuma, Aiko; Kurosu, Takeshi; Watanabe, Shumpei; Shimojima, Masayuki; Shirato, Kazuya; Iwata-Yoshikawa, Naoko; Nagata, Noriyo; Ohnishi, Kazuo; Ato, Manabu; Melaku, Simenew Keskes; Sentsui, Hiroshi; Saijo, Masayuki

    2018-01-01

    Since discovering the Middle East respiratory syndrome coronavirus (MERS-CoV) as a causative agent of severe respiratory illness in the Middle East in 2012, serological testing has been conducted to assess antibody responses in patients and to investigate the zoonotic reservoir of the virus. Although the virus neutralization test is the gold standard assay for MERS diagnosis and for investigating the zoonotic reservoir, it uses live virus and so must be performed in high containment laboratories. Competitive ELISA (cELISA), in which a labeled monoclonal antibody (MAb) competes with test serum antibodies for target epitopes, may be a suitable alternative because it detects antibodies in a species-independent manner. In this study, novel MAbs against the spike protein of MERS-CoV were produced and characterized. One of these MAbs was used to develop a cELISA. The cELISA detected MERS-CoV-specific antibodies in sera from MERS-CoV-infected rats and rabbits immunized with the spike protein of MERS-CoV. The MAb-based cELISA was validated using sera from Ethiopian dromedary camels. Relative to the neutralization test, the cELISA detected MERS-CoV-specific antibodies in 66 Ethiopian dromedary camels with a sensitivity and specificity of 98% and 100%, respectively. The cELISA and neutralization test results correlated well (Pearson's correlation coefficients=0.71-0.76, depending on the cELISA serum dilution). This cELISA may be useful for MERS epidemiological investigations on MERS-CoV infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A Monoclonal Antibody Based Capture ELISA for Botulinum Neurotoxin Serotype B: Toxin Detection in Food

    Directory of Open Access Journals (Sweden)

    Larry H. Stanker

    2013-11-01

    Full Text Available Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT, produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A–H have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD’s for individual antibodies ranging from 10 to 48 × 10−11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D., ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule and readily detects toxin in those food samples tested.

  3. A monoclonal antibody based capture ELISA for botulinum neurotoxin serotype B: toxin detection in food.

    Science.gov (United States)

    Stanker, Larry H; Scotcher, Miles C; Cheng, Luisa; Ching, Kathryn; McGarvey, Jeffery; Hodge, David; Hnasko, Robert

    2013-11-18

    Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT), produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A-H) have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs) capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture) ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD's) for individual antibodies ranging from 10 to 48 × 10-11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D.), ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule) and readily detects toxin in those food samples tested.

  4. Detection of serum antibody levels against newcastle disease in ...

    African Journals Online (AJOL)

    Poultry diseases are one of the main factors constraining poultry practice in most developing countries. Newcastle disease (ND) is a highly contagious and commonly fatal viral poultry disease caused by Newcastle disease virus (NDV). Detection of antibodies to Newcastle disease virus in 300 blood samples from local ...

  5. A novel electrochemical aptamer-antibody sandwich assay for lysozyme detection.

    Science.gov (United States)

    Ocaña, Cristina; Hayat, Akhtar; Mishra, Rupesh; Vasilescu, Alina; del Valle, Manel; Marty, Jean-Louis

    2015-06-21

    In this paper, we have reported a novel electrochemical aptamer-antibody based sandwich biosensor for the detection of lysozyme. In the sensing strategy, an anti-lysozyme aptamer was immobilized onto the carbon electrode surface by covalent binding via diazonium salt chemistry. After incubating with a target protein (lysozyme), a biotinylated antibody was used to complete the sandwich format. The subsequent additions of avidin-alkaline phosphatase as an enzyme label, and a 1-naphthyl phosphate substrate (1-NPP) allowed us to determine the concentration of lysozyme (Lys) via Differential Pulse Voltammetry (DPV) of the generated enzyme reaction product, 1-naphthol. Using this strategy, a wide detection range from 5 fM to 5 nM was obtained for a target lysozyme, with a detection limit of 4.3 fM. The control experiments were carried out by using bovine serum albumin (BSA), cytochrome c and casein. The results showed that the proposed biosensor had good specificity, stability and reproducibility for lysozyme analysis. In addition, the biosensor was applied for detecting lysozyme in spiked wine samples, and very good recovery rates were obtained in the range from 95.2 to 102.0% for lysozyme detection. This implies that the proposed sandwich biosensor is a promising analytical tool for the analysis of lysozyme in real samples.

  6. A Rapid Detection Method of Brucella with Quantum Dots and Magnetic Beads Conjugated with Different Polyclonal Antibodies

    Science.gov (United States)

    Song, Dandan; Qu, Xiaofeng; Liu, Yushen; Li, Li; Yin, Dehui; Li, Juan; Xu, Kun; Xie, Renguo; Zhai, Yue; Zhang, Huiwen; Bao, Hao; Zhao, Chao; Wang, Juan; Song, Xiuling; Song, Wenzhi

    2017-03-01

    Brucella spp. are facultative intracellular bacteria that cause zoonotic disease of brucellosis worldwide. Traditional methods for detection of Brucella spp. take 48-72 h that does not meet the need of rapid detection. Herein, a new rapid detection method of Brucella was developed based on polyclonal antibody-conjugating quantum dots and antibody-modified magnetic beads. First, polyclonal antibodies IgG and IgY were prepared and then the antibody conjugated with quantum dots (QDs) and immunomagnetic beads (IMB), respectively, which were activated by N-(3-dimethylaminopropyl)- N'-ethylcar-bodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to form probes. We used the IMB probe to separate the Brucella and labeled by the QD probe, and then detected the fluorescence intensity with a fluorescence spectrometer. The detection method takes 105 min with a limit of detection of 103 CFU/mL and ranges from 10 to 105 CFU/mL ( R 2 = 0.9983), and it can be well used in real samples.

  7. Cancer imaging with radiolabeled antibodies

    International Nuclear Information System (INIS)

    Goldenberg, D.M.

    1990-01-01

    This book presents a perspective of the use of antibodies to target diagnostic isotopes to tumors. Antibodies with reasonable specificity can be developed against almost any substance. If selective targeting to cancer cells can be achieved, the prospects for a selective therapy are equally intriguing. But the development of cancer detection, or imaging, with radiolabeled antibodies has depended upon advances in a number of different areas, including cancer immunology and immunochemistry for identifying suitable antigen targets and antibodies to these targets, tumor biology for model systems, radiochemistry for he attachment of radionuclides to antibodies, molecular biology for reengineering the antibodies for safer and more effective use in humans, and nuclear medicine for providing the best imaging protocols and instrumentation to detect minute amounts of elevated radioactivity against a background of considerable noise. Accordingly, this book has been organized to address the advances that are being made in many of these areas

  8. Antibody array in a multiwell plate format for the sensitive and multiplexed detection of important plant pathogens.

    Science.gov (United States)

    Charlermroj, Ratthaphol; Himananto, Orawan; Seepiban, Channarong; Kumpoosiri, Mallika; Warin, Nuchnard; Gajanandana, Oraprapai; Elliott, Christopher T; Karoonuthaisiri, Nitsara

    2014-07-15

    The global seed market is considered to be an important industry with a total value of $10,543 million US dollars in 2012. Because plant pathogens such as bacteria and viruses cause a significant economic loss to both producers and exporters, the seed export industry urgently requires rapid, sensitive, and inexpensive testing for the pathogens to prevent disease spreading worldwide. This study developed an antibody array in a multiwell plate format to simultaneously detect four crucial plant pathogens, namely, a bacterial fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac), Chilli veinal mottle virus (ChiVMV, potyvirus), Watermelon silver mottle virus (WSMoV, tospovirus serogroup IV), and Melon yellow spot virus (MYSV, tospovirus). The capture antibodies specific to the pathogens were immobilized on each well at preassigned positions by an automatic microarrayer. The antibodies on the arrays specifically captured the corresponding pathogens present in the sample extracts. The presence of pathogens bound on the capture antibodies was subsequently detected by a cocktail of fluorescently conjugated secondary antibodies. The limits of detection of the developed antibody array for the detection of Aac, ChiVMV, WSMoV, and MYSV were 5 × 10(5) CFU/mL, 30 ng/mL, 1000 ng/mL, and 160 ng/mL, respectively, which were very similar to those of the conventional ELISA method. The antibody array in a multiwell plate format accurately detected plant pathogens in single and multiple detections. Moreover, this format enables easy handling of the assay at a higher speed of operation.

  9. Fluorescently labeled chimeric anti-CEA antibody improves detection and resection of human colon cancer in a patient-derived orthotopic xenograft (PDOX) nude mouse model.

    Science.gov (United States)

    Metildi, Cristina A; Kaushal, Sharmeela; Luiken, George A; Talamini, Mark A; Hoffman, Robert M; Bouvet, Michael

    2014-04-01

    The aim of this study was to evaluate a new fluorescently labeled chimeric anti-CEA antibody for improved detection and resection of colon cancer. Frozen tumor and normal human tissue samples were stained with chimeric and mouse antibody-fluorophore conjugates for comparison. Mice with patient-derived orthotopic xenografts (PDOX) of colon cancer underwent fluorescence-guided surgery (FGS) or bright-light surgery (BLS) 24 hr after tail vein injection of fluorophore-conjugated chimeric anti-CEA antibody. Resection completeness was assessed using postoperative images. Mice were followed for 6 months for recurrence. The fluorophore conjugation efficiency (dye/mole ratio) improved from 3-4 to >5.5 with the chimeric CEA antibody compared to mouse anti-CEA antibody. CEA-expressing tumors labeled with chimeric CEA antibody provided a brighter fluorescence signal on frozen human tumor tissues (P = 0.046) and demonstrated consistently lower fluorescence signals in normal human tissues compared to mouse antibody. Chimeric CEA antibody accurately labeled PDOX colon cancer in nude mice, enabling improved detection of tumor margins for more effective FGS. The R0 resection rate increased from 86% to 96% with FGS compared to BLS. Improved conjugating efficiency and labeling with chimeric fluorophore-conjugated antibody resulted in better detection and resection of human colon cancer in an orthotopic mouse model. © 2013 Wiley Periodicals, Inc.

  10. Tumor detection using radiolabeled monoclonal antibodies

    International Nuclear Information System (INIS)

    Moldofsky, P.J.; Powe, J.; Hammond, N.D.

    1987-01-01

    Radioisotope conjugated to monoclonal antibody products has been used for imaging tumors targeted by the antibody. As imaging progresses, new sets of procedural and technical questions arise. In this chapter, we discuss several current problems in imaging tumor with radiolabeled monoclonal antibody. These include (1) methods for selection of specific antibody and, once the particular antibody is selected, which fragment form is to be used; (2) imaging procedures: what are the optimum imaging parameters, such as optimum time for imaging after administration of tracer and considerations regarding background subtraction; and (3) noninvasive quantitative techniques: quantitation of localization of antibody indirectly from quantitative information in the images.100 references

  11. Cell-free synthesis of functional antibody fragments to provide a structural basis for antibody-antigen interaction.

    Directory of Open Access Journals (Sweden)

    Takayoshi Matsuda

    Full Text Available Growing numbers of therapeutic antibodies offer excellent treatment strategies for many diseases. Elucidation of the interaction between a potential therapeutic antibody and its target protein by structural analysis reveals the mechanism of action and offers useful information for developing rational antibody designs for improved affinity. Here, we developed a rapid, high-yield cell-free system using dialysis mode to synthesize antibody fragments for the structural analysis of antibody-antigen complexes. Optimal synthesis conditions of fragments (Fv and Fab of the anti-EGFR antibody 059-152 were rapidly determined in a day by using a 30-μl-scale unit. The concentration of supplemented disulfide isomerase, DsbC, was critical to obtaining soluble antibody fragments. The optimal conditions were directly applicable to a 9-ml-scale reaction, with linear scalable yields of more than 1 mg/ml. Analyses of purified 059-152-Fv and Fab showed that the cell-free synthesized antibody fragments were disulfide-bridged, with antigen binding activity comparable to that of clinical antibodies. Examination of the crystal structure of cell-free synthesized 059-152-Fv in complex with the extracellular domain of human EGFR revealed that the epitope of 059-152-Fv broadly covers the EGF binding surface on domain III, including residues that formed critical hydrogen bonds with EGF (Asp355EGFR, Gln384EGFR, H409EGFR, and Lys465EGFR, so that the antibody inhibited EGFR activation. We further demonstrated the application of the cell-free system to site-specific integration of non-natural amino acids for antibody engineering, which would expand the availability of therapeutic antibodies based on structural information and rational design. This cell-free system could be an ideal antibody-fragment production platform for functional and structural analysis of potential therapeutic antibodies and for engineered antibody development.

  12. Discrepancies between feline coronavirus antibody and nucleic acid detection in effusions of cats with suspected feline infectious peritonitis.

    Science.gov (United States)

    Lorusso, Eleonora; Mari, Viviana; Losurdo, Michele; Lanave, Gianvito; Trotta, Adriana; Dowgier, Giulia; Colaianni, Maria Loredana; Zatelli, Andrea; Elia, Gabriella; Buonavoglia, Domenico; Decaro, Nicola

    2017-10-31

    Intra-vitam diagnosis of feline infectious peritonitis (FIP) is a challenge for veterinary diagnosticians, since there are no highly specific and sensitive assays currently available. With the aim to contribute to fill this diagnostic gap, a total of 61 effusions from cats with suspected effusive FIP were collected intra-vitam for detection of feline coronavirus (FCoV) antibodies and RNA by means of indirect immunofluorescence (IIF) assay and real-time RT-PCR (qRT-PCR), respectively. In 5 effusions there was no evidence for either FCoV RNA or antibodies, 51 and 52 specimens tested positive by IIF and qRT-PCR, respectively, although antibody titres≥1:1600, which are considered highly suggestive of FIP, were detected only in 37 effusions. Three samples with high antibody levels tested negative by qRT-PCR, whereas 18 qRT-PCR positive effusions contained no or low-titre antibodies. qRT-PCR positive samples with low antibody titres mostly contained low FCoV RNA loads, although the highest antibody titres were detected in effusions with C T values>30. In conclusion, combining the two methods, i.e., antibody and RNA detection would help improving the intra-vitam diagnosis of effusive FIP. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Initial study with Tc99m antigranulocyte antibody (MAK-47) in detection sources of infection

    International Nuclear Information System (INIS)

    Cwikla, J.B.; Buscombe, J.R.; Hilson, A.J.; Janoki, G.A.

    1997-01-01

    Antigranulocytes antibodies (AGAB) are antibodies directed against glycoprotein on the surface of granulocytes and as such provides in vivo cell labelling. They are easily labelled with Tc99m and comes a one step labelling technique. 20 patients have been studied 1 h and 4-6 hours after administration of 200 MBq of Tc99m AGAB (MAK-47). Less then 0.5 mg of antibody was given to each patients. Sites of uptake and outside of the reticular-endothelial system were reported as showing positive accumulation. Clinical results were confirmed by microbiological, pathological examinations, clinical follow-up and autopsy. There were 8 patients who had sites of infection confirmed by additional examination. All patients were visualized by Tc99m AGAB (MAK-47). There were 4 cases of osteomyelitis and septic arthritis and 4 cases of focal intra-abdominal infection. Two patients had uptake in non-infected/inflammatory arthritis, both in the knee. The remaining patients had true negative studies. The diagnostic accuracy of this study was as follows: sensitivity 100%, specificity 83%, positive predictive value (PPV) was 80% and negative predictive value (NPV) was 100%. Antigranulocyte antibody (MAK-47) seems to by promising tool in detecting focal infection in bone and soft tissue, except physiological accumulation in some parts of the body. It should be considered that antibodies can have non-specific uptake in non-infected, inflammation sites. It is easy to use and no had allergic reaction and HAMA antibody (human antimouse antibody). (author)

  14. Tus-Ter-lock immuno-PCR assays for the sensitive detection of tropomyosin-specific IgE antibodies.

    Science.gov (United States)

    Johnston, Elecia B; Kamath, Sandip D; Lopata, Andreas L; Schaeffer, Patrick M

    2014-02-01

    The increasing prevalence of food allergies requires development of specific and sensitive tests capable of identifying the allergen responsible for the disease. The development of serologic tests that can detect specific IgE antibodies to allergenic proteins would, therefore, be highly received. Here we present two new quantitative immuno-PCR assays for the sensitive detection of antibodies specific to the shrimp allergen tropomyosin. Both assays are based on the self-assembling Tus-Ter-lock protein-DNA conjugation system. Significantly elevated levels of tropomyosin-specific IgE were detected in sera from patients allergic to shrimp. This is the first time an allergenic protein has been fused with Tus to enable specific IgE antibody detection in human sera by quantitative immuno-PCR.

  15. A Generic Method for Fungal Spore Detection: The use of a monoclonal antibody and surface plasmon resonance

    DEFF Research Database (Denmark)

    Skottrup, Peter; Hearty, Stephen; Frøkiær, Hanne

    2005-01-01

    This study describes a biosensing principle for detection of fungal spores using surface plasmon resonance (SPR). The approach involves the use of a monoclonal antibody (mab) and a SPR sensor for label-free detection of the model organism Puccinia striiformis f.sp. tritici (Pst) a biotrophic fungus...... causing wheat yellow rust. We have developed mabs towards intact whole spores and used a subtractive inhibition format for detection of spores in solution. The antibody was incubated with different spore concentrations and the remaining free antibody was quantified using a BIAcore® 3000 sensor. Decreasing...

  16. Detection of polyaromatic compounds using antibody-based fiberoptics fluoroimmunosensors

    International Nuclear Information System (INIS)

    Vo-Dinh, T.; Tromberg, B.J.; Griffin, G.D.; Ambrose, K.R.; Sepaniak, M.J.; Alarie, J.P.

    1987-01-01

    In this work we have investigated the performance of an antibody-based fiberoptics sensor for the detection of the carcinogen benzo(a)pyrene and its DNA-adduct product BP-tetrol. The excellent sensitivity of this device - femtomole limits of detection for BP - illustrates that it has considerable potential to perform analyses of chemical and biological samples at trace levels in complex matrices. The results indicate that fiberoptics-based fluoroimmunosensors can be useful in a wide spectrum of biochemical and clinical analyses. 17 refs., 4 figs., 1 tab

  17. Detection of polyaromatic compounds using antibody-based fiberoptics fluoroimmunosensors

    Energy Technology Data Exchange (ETDEWEB)

    Vo-Dinh, T.; Tromberg, B.J.; Griffin, G.D.; Ambrose, K.R.; Sepaniak, M.J.; Alarie, J.P.

    1987-01-01

    In this work we have investigated the performance of an antibody-based fiberoptics sensor for the detection of the carcinogen benzo(a)pyrene and its DNA-adduct product BP-tetrol. The excellent sensitivity of this device - femtomole limits of detection for BP - illustrates that it has considerable potential to perform analyses of chemical and biological samples at trace levels in complex matrices. The results indicate that fiberoptics-based fluoroimmunosensors can be useful in a wide spectrum of biochemical and clinical analyses. 17 refs., 4 figs., 1 tab.

  18. [VGKC-complex antibodies].

    Science.gov (United States)

    Watanabe, Osamu

    2013-04-01

    Various antibodies are associated with voltage-gated potassium channels (VGKCs). Representative antibodies to VGKCs were first identified by radioimmunoassays using radioisotope-labeled alpha-dendrotoxin-VGKCs solubilized from rabbit brain. These antibodies were detected only in a proportion of patients with acquired neuromyotonia (Isaacs' syndrome). VGKC antibodies were also detected in patients with Morvan's syndrome and in those with a form of autoimmune limbic encephalitis. Recent studies indicated that the "VGKC" antibodies are mainly directed toward associated proteins (for example LGI-1 and CASPR-2) that complex with the VGKCs themselves. The "VGKC" antibodies are now commonly known as VGKC-complex antibodies. In general, LGI-1 antibodies are most commonly detected in patients with limbic encephalitis with syndrome of inappropriate secretion of antidiuretic hormone. CASPR-2 antibodies are present in the majority of patients with Morvan's syndrome. These patients develop combinations of CNS symptoms, autonomic dysfunction, and peripheral nerve hyperexcitability. Furthermore, VGKC-complex antibodies are tightly associated with chronic idiopathic pain. Hyperexcitability of nociceptive pathways has also been implicated. These antibodies may be detected in sera of some patients with neurodegenerative diseases (for example, amyotrophic lateral sclerosis and Creutzfeldt-Jakob disease).

  19. Detection of antibodies to avian influenza, infectious bronchitis and ...

    African Journals Online (AJOL)

    Detection of antibodies to avian influenza, infectious bronchitis and Newcastle disease viruses in wild birds in three states of Nigeria. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like more ...

  20. Application of synthetic peptides for detection of anti-citrullinated peptide antibodies

    DEFF Research Database (Denmark)

    Trier, Nicole Hartwig; Holm, Bettina Eide; Slot, Ole

    2016-01-01

    Anti-citrullinated protein antibodies (ACPAs) are a hallmark of rheumatoid arthritis (RA) and represent an important tool for the serological diagnosis of RA. In this study, we describe ACPA reactivity to overlapping citrullinated Epstein-Barr virus nuclear antigen-1 (EBNA-1)-derived peptides...... (n=40), systemic lupus erythematosus (n=20), Sjögren's syndrome (n=40)) were screened for antibody reactivity. Antibodies to a panel of five citrullinated EBNA-1 peptides were found in 67% of RA sera, exclusively of the IgG isotype, while 53% of the patient sera reacted with a single peptide......, ARGGSRERARGRGRG-Cit-GEKR, accounting for more than half of the ACPA reactivity alone. Moreover, these antibodies were detected in 10% of CCP2-negative RA sera. In addition, 47% of the RA sera reacted with two or three citrullinated EBNA-1 peptides from the selected peptide panel. Furthermore, a negative...

  1. Micro solid-phase radioimmunoassay for detection of herpesvirus type-specific antibody: specificity and sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Adler-Storthz, K.; Matson, D.O.; Adam, E.; Dreesman, G.R. (Baylor Univ., Houston, TX (USA). Coll. of Medicine)

    1983-02-01

    The specificity and sensitivity of a micro solid-phase radioimmunoassay (micro-SPRIA) that detects type-specific IgG antibody to herpes simplex virus types 1 and 2 (HSV1 and HSV2) were evaluated. Glycoproteins VP123 (molecular weight, 123,000) of HSV1 and VP119 (molecular weight, 119,000) of HSV2 were found to display the greatest degree of antigenic type-specificity of several HSV antigens tested with the micro-SPRIA technique. When testing a group of sera, negative for anti-HSV antibodies by microneutralization, in the micro-SPRIA, a range of negative reactivities was noted, suggesting that cut-points should be determined for each antigen preparation. The micro-SPRIA detected appropriate antibody activity in patients with recurrent infection and a marked agreement was noted in comparison to detection of anti-HSV antibodies measured with the microneutralization test. The type-specificity of the micro-SPRIA was substantiated by the independence of test results using VP119 and VP123 antigens for a random group of positive sera. The assay is rapid, specific, and sensitive and allows the testing of multiple serum samples with a standardized set of reagents.

  2. Detection of B-lymphocytes secreting antibodies to Dermatophagoides antigens

    DEFF Research Database (Denmark)

    Sparholt, S H; Barington, T; Schou, C

    1991-01-01

    Alutard, showed that 1 week after injection, circulating allergen-specific antibody-secreting cells (AbSC) were detected with this assay. The ranges were between 1 and 13 IgM-, 2 and 20 IgG- and 20 and 55 IgA allergen-specific AbSC per 10(6) MNC. It is expected that this assay will help to understand more...

  3. Radioimmunoassay test system for detection of anti-insulin antibodies

    International Nuclear Information System (INIS)

    Dudko, N.V.; Piven', N.V.; Ibragimova, G.V.; Kasatkin, Yu.N.

    1995-01-01

    A radiodiagnostic test system has been developed and commercial kit for radioimmunoassay of anti-insulin antibodies in human blood serum created. Clinical trials of the kit in patients (150 diabetics with types 1 and 2 condition) and normal subjects (n=100) demonstrated the possibility of using this kit for the detection of preclinical forms of diabetes and for distinguishing groups at risk of diabetes among children and adults, for the detection of insulin resistance, for the differential diagnosis of diabetes, and for monitoring the efficacy of insulin therapy. 9 refs.; 1 tab

  4. Evaluation of commercial ELISA kits for detection of antibodies against bovine atypical pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Uttenthal, Åse

    A group of emerging bovine pestiviruses becomes a possible threat to Bovine Viral diarrhea virus (BVDV) control and eradication programs in the countries of their origin and in the new continents due to the lack of validated detection methods. The use of ELISA kits may be acheaper, time saving...... and less laborious option allowing screening for antibodies in large populations. Since test specific for emerging and new BVDV strains are still under preparation, the purpose of this work was to evaluate available BVDV antibody ELISA assays for their ability to detect antibodies against Hobi-like viruses....... Analysis of a panel of sera obtained from calves experimentally inoculated with Hobi-like virus (isolated from a calf from Thailand) and BVDV type 1 strain using five different ELISA kits in comparison to neutralization test was performed. The specificity and sensitivity of the tests depended greatly...

  5. Colorectal carcinoma metastases: Detection with In-111-labeled monoclonal antibody CCR 086

    International Nuclear Information System (INIS)

    Abdel-Nabi, H.H.; Levine, G.; Lamki, L.M.; Murray, J.L.; Tauxe, W.N.; Shah, A.N.; Patt, Y.Z.; Doerr, R.J.; Klein, H.A.; Gona, J.

    1990-01-01

    A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses of 5 and 20 mg. Of 25 known lesions, 17 were detected (sensitivity, 68%). The smallest detected lesion in the lung was 1 cm and in the liver was 1.5 cm. The serum half-life of In-111-labeled CCR 086 MoAb was approximately 64 hours. The formation of human antimouse antibody (HAMA) was detected in the serum of four of five patients who received 20 mg of MoAb. No HAMAs were detected in four patients receiving 5 mg of MoAb. No side effects were encountered. Because of effective detection of liver and lung metastases with lower doses (5-20 mg) of CCR 086 conjugated with In-111, further investigations are warranted to assess clinical and therapeutic potentials of CCR 086 in the management of colorectal cancer

  6. A nanofluidic bioarray chip for fast and high-throughput detection of antibodies in biological fluids

    Science.gov (United States)

    Lee, Jonathan; Gulzar, Naveed; Scott, Jamie K.; Li, Paul C. H.

    2012-10-01

    Immunoassays have become a standard in secretome analysis in clinical and research analysis. In this field there is a need for a high throughput method that uses low sample volumes. Microfluidics and nanofluidics have been developed for this purpose. Our lab has developed a nanofluidic bioarray (NBA) chip with the goal being a high throughput system that assays low sample volumes against multiple probes. A combination of horizontal and vertical channels are produced to create an array antigens on the surface of the NBA chip in one dimension that is probed by flowing in the other dimension antibodies from biological fluids. We have tested the NBA chip by immobilizing streptavidin and then biotinylated peptide to detect the presence of a mouse monoclonal antibody (MAb) that is specific for the peptide. Bound antibody is detected by an AlexaFluor 647 labeled goat (anti-mouse IgG) polyclonal antibody. Using the NBA chip, we have successfully detected peptide binding by small-volume (0.5 μl) samples containing 50 attomoles (100 pM) MAb.

  7. Radioimmunoassay for detecting antibodies against murine malarial parasite antigens: monoclonal antibodies recognizing Plasmodium yoelii antigens

    International Nuclear Information System (INIS)

    Kim, K.J.; Taylor, D.W.; Evans, C.B.; Asofsky, R.

    1980-01-01

    A solid-phase radioimmunoassay (SPRIA) in microtiter wells was established for detecting antibodies against Plasmodium yoelii Ag. The SPRIA was found (1) to require as little as 5 μg of crude parasite Ag per well, (2) to be able to detect 0.5 ng of monoclonal Ab, and (3) to be 10 4 times more sensitive than the indirect fluorescent Ab staining technique. In a modification of the above assay using intact RBC as an Ag, hyperimmune serum showed significant binding to the surface of erythrocytes of mice infected with P. yoelii parasites but not to RBC of normal mice. Hybridomas were prepared by fusing infected mouse spleen cells with myeloma cells. Using the SPRIA, hybrids secreting Ab against P. yoelii 17XL Ag were detected

  8. Detection of serum anti-B/B’ UsnRNP antibodies in patients with connective tissue diseases by immunoblotting

    Directory of Open Access Journals (Sweden)

    L. Iaccarino

    2011-09-01

    Full Text Available Objective: To investigate the reliability of the immunoblot method in the detection of serum immunoreactivity towards the B/B’ polypeptides of U small nuclear ribonucleoproteins (UsnRNP and to assess the significance of these antibodies in connective tissue disease (CTD patients. Methods: We tested the sera of 348 patients with CTD (101 SLE, 51 systemic sclerosis, 53 primary Sjogren’s syndrome, 27 poly/dermatomyositis, 15 rheumatoid arthritis and 101 overlap CTD, of 31 matched healthy subjects and 13 patients with primary Epstein-Barr virus (EBV infection with high titre IgG anti-EBV antibodies. IgG anti-UsnRNP antibodies were determined by immunoblotting on nuclear extract from Raji cells (an EBV-immortalised human B lymphoid cell line and Jurkat cells (a human T lymphoid cell line. Anti-dsDNA antibodies were detected by indirect immunofluorescence on Crithidia luciliae and anti-ENA by counterimmunoelectrophoresis. Anti-dsDNA activity and avidity were measured in SLE sera by ELISA with Scatchard analysis. Results were statistically analysed by chi-square and Mann-Whitney tests. Results: A high frequency of anti-B/B’ antibodies was found in the sera of CTD patients, confined to SLE (54.4% and overlap CTD with SLE features (55,2%. Anti-B/B’ immune reactivity was closely associated with other anti-UsnRNP specificities, gel precipitating anti-nRNP and anti-P antibodies. Nine out of 15 (60% anti-B/B’ positive/anti-ENA negative lupus sera on Raji blots were confirmed to be positive also on Jurkat blots. The sera from patients with EBV infection provided, on Raji blots, completely different band patterns from those obtained with auto-immune sera. Conclusions. The Sm B/B’ proteins are the predominant or, at least, the most frequently targeted antigens of the UsnRNP auto-immune response in SLE and “lupus-like” overlap CTD. Moreover, anti-B/B’ is diagnostically specific for CTD with SLE features. Immunoblotting on human B lymphoid cells

  9. A commercial ELISA detects high levels of human H5 antibody but cross-reacts with influenza A antibodies.

    Science.gov (United States)

    Stelzer-Braid, Sacha; Wong, Bruce; Robertson, Peter; Lynch, Garry W; Laurie, Karen; Shaw, Robert; Barr, Ian; Selleck, Paul W; Baleriola, Cristina; Escott, Ros; Katsoulotos, Gregory; Rawlinson, William D

    2008-10-01

    Commercial serological assays to determine influenza A H5N1 infection are available, although the accuracy and reproducibility of these are not reported in detail. This study aimed to assess the validity of a commercial ELISA H5 hemagglutinin (HA) antibody kit. A commercial ELISA for detection of antibodies towards influenza A H5 HA was evaluated using human sera from vaccinated individuals. The ELISA was used to screen 304 sera with elevated influenza A complement fixation titres collected between the period 1995-2007. The ELISA was found to be accurate for sera with high levels of anti-H5 antibodies, and would be useful in clinical settings where a rapid result is required. Thirteen of the stored sera were positive using the ELISA, but were confirmed as negative for H5N1 exposure using further serological tests. Absorption studies suggested that antibodies towards seasonal H3N2 and H1N1 influenza may cross-react with H5 antigen, giving false positive results with the ELISA.

  10. Anti-double stranded DNA antibodies in systemic lupus erythematosus : Detection and clinical relevance of IgM-class antibodies

    NARCIS (Netherlands)

    Bootsma, H; Spronk, PE; Hummel, EJ; deBoer, G; terBorg, EJ; Limburg, PC; Kallenberg, CGM

    1996-01-01

    We determined the discriminative value of the Farr assay in comparison to ELISA and Crithidia luciliae immunofluorescence assay (IFT) for detecting anti-dsDNA antibodies as a diagnostic tool for systemic lupus erythematosus (SLE). Special attention was paid to the diagnostic significance of

  11. Antibody-Based Detection of ERG Rearrangement-Positive Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Kyung Park

    2010-07-01

    Full Text Available TMPRSS2-ERG gene fusions occur in 50% of prostate cancers and result in the overexpression of a chimeric fusion transcript that encodes a truncated ERG product. Previous attempts to detect truncated ERG products have been hindered by a lack of specific antibodies. Here, we characterize a rabbit anti-ERG monoclonal antibody (clone EPR 3864; Epitomics, Burlingame, CA using immunoblot analysis on prostate cancer cell lines, synthetic TMPRSS2-ERG constructs, chromatin immunoprecipitation, and immunofluorescence. We correlated ERG protein expression with the presence of ERG gene rearrangements in prostate cancertissues using a combined immunohistochemistry(IHC and fluorescence in situ hybridization (FISH analysis. We independently evaluated two patient cohorts and observed ERG expression confined to prostate cancer cells and high-grade prostatic intraepithelial reoplasia associated with ERG-positive cancer, as well as vessels and lymphocytes (where ERG has a known biologic role. Image analysis of 131 cases demonstrated nearly 100% sensitivity for detecting ERG rearrangement prostate cancer, with only 2 (1.5% of 131 cases demonstrating strong ERG protein expression without any known ERG gene fusion. The combired pathology evaluation of 207 patient tumors for ERG protein expression had 95.7% sensitivity and 96.5% specificity for determining ERG rearrangement prostate cancer. Ir conclusion, this study qualifies a specific anti-ERG antibody and demonstrates exquisite association between ERG gene rearrangement and truncated ERG protein product expression. Giver the ease of performing IHC versus FISH, ERG protein expression may be useful for molecularly subtypirg prostate cancer based or ERG rearrangement status and suggests clinical utility it prostate needle biopsy evaluation.

  12. Evaluation of Salivary Antibodies to Detect Infection with Helicobacter pylori

    Directory of Open Access Journals (Sweden)

    Mark B Loeb

    1997-01-01

    Full Text Available Helicobacter pylori infection is an important cause of peptic ulcer disease and chronic gastritis. Infection with this bacterium stimulates the production of immunoglobulin (Ig G antibody. Salivary IgG antibody tests to detect H pylori infection offer a convenient and noninvasive method of diagnosis. To evaluate an IgG salivary antibody kit, saliva was collected from 157 out-patients with dyspepsia referred for endoscopy to a tertiary centre. A salivary IgG ELISA antibody assay was performed using the Helisal Helicobacter pylori (IgG assay kit, and at least four gastric biopsies were obtained. H pylori infection was confirmed by demonstration of the organism on Warthin-Starry silver stain (sensitivity 85%, specificity 55%. The prevalence of infection with H pylori was 30%. When the analysis was redone, excluding those treated with eradication therapy, the results were similar (sensitivity 86%, specificity 58%. The positive predictive value of the assay was 45% and the negative predictive value was 90%. Despite the ease of sampling, the assay used has limited diagnostic utility, lacking the predictive value to indicate which patients referred with dyspeptic symptoms to a tertiary care setting are infected with H pylori.

  13. Radioimmunoassay for the detection of virus-specific IgA antibodies in saliva

    International Nuclear Information System (INIS)

    Friedman, M.G.

    1982-01-01

    The use of a sensitive and versatile radioimmunoassay (RIA) for detection of mumps-specific IgA and measles-specific IgA in unconcentrated saliva samples is described. The samples were obtained either by expectoration or by swabbing of the oral cavity, with or without stimulation of secretion, and were inactivated and clarified before testing. Mumps-specific IgA antibodies were detected as early as one day after onset of illness and peaked at 1-2 weeks after onset. Measles-specific salivary IgA antibodies were detected in 15-month old children 2-3 weeks after immunization. These results suggest that the RIA technique may be useful for early diagnosis of viral infections and for confirmation of response to immunization without the need for a blood sample, as well as for the study of the secretory immune response in very young and older subjects. (Auth.)

  14. Evaluation of a technique for the intraoperative detection of a radiolabelled monoclonal antibody against colorectal cancer

    International Nuclear Information System (INIS)

    Waddington, W.A.; Todd-Pokropek, A.; Short, M.D.; Davidson, B.R.; Boulos, P.B.; Middlesex Hospital, London

    1991-01-01

    Occult tumour deposits may be localised at operation with a radiation detecting probe following the administration of a radiolabelled monoclonal antibody (MoAb) recognising a tumour-associated antigen. We have recently evaluated the clinical usefulness of this technique in detecting primary colorectal tumours targetted with an indium-111 MoAb. In the present study the physical characteristics of the two detector systems used were investigated; a sodium iodide [NaI(Tl)] scintilation detector and a cadmium telluride (CdTe) semiconductor probe. Limitations of the technique in use have been examined by testing the statistical significance of tumour detecting using an abdominal phantom based on the currently available clinical biodistribution data for tumour uptake of radiolabelled MoAbs. The effect of tumour volume, antibody uptake, collimation and counting conditions was examined. Results indicate that tumours of 10-ml volume may be detected with the NaI(Tl) probe at the lowest levels of radiolabelled antibody uptake currently reported in the literature but that at higher published levels, lesions as small as 1 ml may be identified with both detector systems. Detector sensitivity and limited antibody specificity restrict the usefulness of the technique, although moderate improvements in tumour uptake may allow the detection of tumour deposits not clinically apparent. The statistical significance criterion used for this study could be an accurate and reliable indicator for tumour detection in vivo. (orig.)

  15. Detection of hepatitis B virus infection in HBsAg-negative patients by monoclonal antibodies against HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Y K

    1986-11-01

    The technique of producing antibody secreting hybridomas has made available high-affinity antibodies of predefined specificity for use as diagnostic reagents. Recently, high-affinity monoclonal antibodies to hepatitis B surface antigens (HBsAg) were produced and characterized. Immunoassay was developed using these antibodies for the detection of HBsAg-associated determinants. The present study indicated the significance of the enhanced detection by monoclonal radioimmunoassay (M-RIA) of HBsAg in sera of patients with hepatitis B virus infection. The M-RIA detected HBsAg in sera of hemodialysis patients and blood donor defined as HBsAg-negative by polyclonal RIA (2.2 %, 0.14 %, respectively). Furthermore, individuals with chronic liver diseases were reactive only in the M-RIA (chronic hepatitis 4.8 %, liver cirrhosis 10.0 %, hepatocellular carcinoma 22.2 %). It is noteworthy that some of these patients were diagnosesed as so-called non-A non-B hepatitis because of no serological markers of hepatitis B virus infection such as HBsAb and HBcAb. The enhanced performance of the monoclonal RIA compared to conventional RIA was due to the increased sensitivity of the assay (55 pg vs 230 pg/ml). In immunohistochemical study, one of the monoclonal antibody named 5C3 was applied for detection of HBsAg in the formalin-fixed paraffin-embedded liver. HBsAg was detected in 6 out of 41 HBsAg-seronegative liver specimen. Thus, the studies showed the importance of the clinical application of monoclonal antibodies such as immunoassay and immunohistochemical study in the diagnosis of hepatitis B virus infection.

  16. Detection of hepatitis B virus infection in HBsAg-negative patients by monoclonal antibodies against HBsAg

    International Nuclear Information System (INIS)

    Fujita, Y.K.

    1986-01-01

    The technique of producing antibody secreting hybridomas has made available high-affinity antibodies of predefined specificity for use as diagnostic reagents. Recently, high-affinity monoclonal antibodies to hepatitis B surface antigens (HBsAg) were produced and characterized. Immunoassay was developed using these antibodies for the detection of HBsAg-associated determinants. The present study indicated the significance of the enhanced detection by monoclonal radioimmunoassay (M-RIA) of HBsAg in sera of patients with hepatitis B virus infection. The M-RIA detected HBsAg in sera of hemodialysis patients and blood donor defined as HBsAg-negative by polyclonal RIA (2.2 %, 0.14 %, respectively). Furthermore, individuals with chronic liver diseases were reactive only in the M-RIA (chronic hepatitis 4.8 %, liver cirrhosis 10.0 %, hepatocellular carcinoma 22.2 %). It is noteworthy that some of these patients were diagnosesed as so-called non-A non-B hepatitis because of no serological markers of hepatitis B virus infection such as HBsAb and HBcAb. The enhanced performance of the monoclonal RIA compared to conventional RIA was due to the increased sensitivity of the assay (55 pg vs 230 pg/ml). In immunohistochemical study, one of the monoclonal antibody named 5C3 was applied for detection of HBsAg in the formalin-fixed paraffin-embedded liver. HBsAg was detected in 6 out of 41 HBsAg-seronegative liver specimen. Thus, the studies showed the importance of the clinical application of monoclonal antibodies such as immunoassay and immunohistochemical study in the diagnosis of hepatitis B virus infection. (author)

  17. A liquid phase blocking ELISA for the detection of antibodies against infectious bronchitis virus

    Directory of Open Access Journals (Sweden)

    Cardoso T.C.

    1999-01-01

    Full Text Available A liquid phase blocking ELISA (LPB-ELISA was developed for the detection and measurement of antibodies against infectious bronchitis virus (IBV. The purified and nonpurified virus used as antigen, the capture and detector antibodies, and the chicken hyperimmune sera were prepared and standardized for this purpose. A total of 156 sera from vaccinated and 100 from specific pathogen-free chickens with no recorded contact with the virus were tested. The respective serum titers obtained in the serum neutralization test (SNT were compared with those obtained in the LPB-ELISA. There was a high correlation (r2 = 0.8926 between the two tests. The LPB-ELISA represents a single test suitable for the rapid detection of antibodies against bronchitis virus in chicken sera, with good sensitivity (88%, specificity (100% and agreement (95.31%.

  18. Label Free QCM Immunobiosensor for AFB1 Detection Using Monoclonal IgA Antibody as Recognition Element

    Directory of Open Access Journals (Sweden)

    Özlem Ertekin

    2016-08-01

    Full Text Available This study introduces the use of an IgA isotype aflatoxin (AF specific monoclonal antibody for the development of a highly sensitive Quartz Crystal Microbalance (QCM immunobiosensor for the detection of AF in inhibitory immunoassay format. The higher molecular weight of IgA antibodies proved an advantage over commonly used IgG antibodies in label free immunobiosensor measurements. IgA and IgG antibodies with similar affinity for AF were used in the comparative studies. Sensor surface was prepared by covalent immobilization of AFB1, using self assembled monolayer (SAM formed on gold coated Quartz Crystal, with 1-Ethyl-3-(3-dimethylaminopropyl carbodiimide/N-hydroxy succinimide (EDC/NHS method using a diamine linker. Nonspecific binding to the surface was decreased by minimizing the duration of EDC/NHS activation. Sensor surface was chemically blocked after AF immobilization without any need for protein blocking. This protein free sensor chip endured harsh solutions with strong ionic detergent at high pH, which is required for the regeneration of the high affinity antibody-antigen interaction. According to the obtained results, the detection range with IgA antibodies was higher than IgG antibodies in QCM immunosensor developed for AFB1.

  19. Indirect solid-phase immunosorbent assay for detection of arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A [Institute of Poliomyelitis anU Viral Encephalities of the U.S.S.R. Academy of Medical Sciences, Moscow

    1984-05-01

    Indirect enzyme-linked immunosorbent assay (ELISA) and solid phase radioimmunoassay (SPRIA) using either enti-human or anti-mouse IgG labelled with horseradish peroxidase and /sup 125/I, respectively, were developed for the detection of Junin, Machupo, Tacaribe, Amapari, Tamiami, Lassa and LCM arenaviruses. Both methods allow high sensitivity detection of arenavirus antigens and antibodies.

  20. An improved haemolytic plaque assay for the detection of cells secreting antibody to bacterial antigens

    DEFF Research Database (Denmark)

    Barington, T; Heilmann, C

    1992-01-01

    Recent advances in the development of conjugate polysaccharide vaccines for human use have stimulated interest in the use of assays detecting antibody-secreting cells (AbSC) with specificity for bacterial antigens. Here we present improved haemolytic plaque-forming cell (PFC) assays detecting Ab......SC with specificity for tetanus and diphtheria toxoid as well as for Haemophilus influenzae type b and pneumococcal capsular polysaccharides. These assays were found to be less time consuming, more economical and yielded 1.9-3.4-fold higher plaque numbers than traditional Jerne-type PFC assays. In the case of anti......-polysaccharide antibodies aggregation of secreted monomeric antibody (IgG) is critical for plaque formation and increases the avidity of binding to target cells....

  1. Detection of anti neutrophil antibodies by radio-iodinated protein A binding test

    International Nuclear Information System (INIS)

    Cartron, J.; Muller, J.Y.; Tchernia, G.; Paule, B.; Varet, B.

    1983-01-01

    The granulocyte associated IgG in normal and neutropenic subjects has been determined by a direct quantitative assay using radiolabeled staphylococcal protein A. This assay allows to postulate an immunological mechanism to explain the neutropenia in 19 cases of neutropenias associated with malfunctions of the immune system and in 4 cases of idiopathic neutropenias. Discussed in this report is the possible interaction of immune complexes bound in vivo to the granulocytes. By an immunofluorescence test, it has been possible to detect IgG or IgM antibodies in only 52% of patients with a positive direct assay. The determination of granulocyte-associated IgG is therefore a better indicator for defining an auto-immune neutropenia than the detection of free antibodies in the sera [fr

  2. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  3. A three-layer immunoradiometric assay for antibodies in different immunoglobulin classes and its application to the detection of chicken thyroglobulin autoantibodies and of antibodies to sheep erythrocytes

    International Nuclear Information System (INIS)

    Carvalho, L.C.P. de; Roitt, I.M.; Wick, G.

    1980-01-01

    A versatile solid-phase assay for detection of antibodies in different immunoglobulin classes is described. The assay has been applied to: (1) the detection of IgG and IgM antithyroglobulin autoantibodies in chickens with spontaneous autoimmune thyroiditis, and (2) the detection of anti-sheep cell antibodies in normal chickens. Thyroglobulin-coated plastic tubes or formaldehyde-fixed sheep erythrocytes were used as the solid phase. Antisera were added in succession to the solid-phase antigen so as to form 3 antibody layers: (1) chicken antibody against the solid-phase antigen; (2) heavy-chain-specific rabbit anti-chicken immunoglobulin; and (3) 125 I-labelled goat anti-rabbit immunoglobulin. The assay is suitable for routine determinations on large numbers of samples; its sensitivity enables small volumes of serum to be tested and allows considerable economy in the use of valuable class-specific antisera. The radiolabelled reagent can be readily applied to other assays employing rabbit antisera. (Auth.)

  4. Production of monoclonal antibodies for sandwich immunoassay detection of ciguatoxin 51-hydroxyCTX3C.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Inoue, Masayuki; Tatami, Atsushi; Miyazaki, Keisuke; Hirama, Masahiro

    2006-09-01

    Every year, more than 50,000 people in subtropical and tropical regions suffer from ciguatera seafood poisoning. The extremely low level of the causative neurotoxins (ciguatoxins) in fish has hampered the preparation of antibodies for detection of the toxins. In this study, we produced a monoclonal antibody (8H4) against the right end of ciguatoxin CTX1B (1) and 51-hydroxyCTX3C (3) by immunizing mice with the keyhole limpet hemocyanin-conjugate of the synthetic HIJKLM ring fragment (10). We used 8H4 and another previously reported monoclonal antibody (10C9) that recognizes the left end of 3 to develop a sandwich enzyme-linked immunosorbent assay (ELISA) to detect 3. The assay could detect 3 down to the ppb level and lacked cross-reactivity with other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, and maitotoxin.

  5. Radiolabelled antibody imaging

    International Nuclear Information System (INIS)

    Perkins, A.C.

    1986-01-01

    A steadily growing number of tumor-associated antigens are used to raise antibodies used for the detection of human tumors by external imaging, a technique termed immunoscintigraphy. The majority of these clinical antibody studies are performed using Iodine-131, which is cheap, readily available and easily attached to protein. It has the disadvantage of having a high energy gamma emission (365 keV) which is poorly detected by modern cameras, so that increasing use is now being made of more appropriate labels with lower energies for imaging, such as Iodine-123, Indium-111 and Technetium-99m. A number of research centres in the United Kingdom are currently involved in the production of tumor-associated monoclonal antibodies, only a small number of which are finally selected for diagnostic use. These developments represent a major area of advancement in Nuclear Medicine and when used for imaging are capable of providing diagnostic information complimentary to other diagnostic techniques

  6. Use of filter paper blood samples for rabies antibody detection in foxes and raccoon dogs.

    Science.gov (United States)

    Wasniewski, Marine; Barrat, Jacques; Combes, Benoit; Guiot, Anne Laure; Cliquet, Florence

    2014-08-01

    The effectiveness of oral rabies vaccination in wildlife is usually evaluated by the detection of rabies antibodies. However, the assessment of rabies antibodies has several technical difficulties in the field, such as the collection, storage, transport and titration of blood samples, often of poor quality. The objective of this study was to assess the feasibility of collecting blood on a filter paper (FP) coupled with enzyme-linked immunosorbent assay (ELISA) titration of rabies antibodies in raccoon dogs and red foxes. The FP blood sampling method was found highly specific and repeatable in both species. Overall, results obtained with the FP sampling method were highly concordant with the conventional (venipuncture) sampling methods. Blood eluates from FP samples from foxes and raccoon dogs tested using ELISA showed concordance values of 92% and 95%, respectively, with serum samples tested using the seroneutralisation test and values of 95% and 91%, respectively, when the ELISA was used on both types of sample. The use of FP blood sampling coupled with the titration of rabies antibodies by ELISA provides a reliable alternative to conventional blood sampling and serum testing by seroneutralisation. This simple procedure is particularly attractive and cost-effective for assessing the effectiveness of oral rabies vaccination in field conditions. Copyright © 2014. Published by Elsevier B.V.

  7. Effective surveillance for early classical swine fever virus detection will utilize both virus and antibody detection capabilities.

    Science.gov (United States)

    Panyasing, Yaowalak; Kedkovid, Roongtham; Thanawongnuwech, Roongroje; Kittawornrat, Apisit; Ji, Ju; Giménez-Lirola, Luis; Zimmerman, Jeffrey

    2018-03-01

    Early recognition and rapid elimination of infected animals is key to controlling incursions of classical swine fever virus (CSFV). In this study, the diagnostic characteristics of 10 CSFV assays were evaluated using individual serum (n = 601) and/or oral fluid (n = 1417) samples collected from -14 to 28 days post inoculation (DPI). Serum samples were assayed by virus isolation (VI), 2 commercial antigen-capture enzyme-linked immunosorbent assays (ELISA), virus neutralization (VN), and 3 antibody ELISAs. Both serum and oral fluid samples were tested with 3 commercial real-time reverse transcription-polymerase chain reaction (rRT-PCR) assays. One or more serum samples was positive by VI from DPIs 3 to 21 and by antigen-capture ELISAs from DPIs 6 to 17. VN-positive serum samples were observed at DPIs ≥ 7 and by antibody ELISAs at DPIs ≥ 10. CSFV RNA was detected in serum samples from DPIs 2 to 28 and in oral fluid samples from DPIs 4 to 28. Significant differences in assay performance were detected, but most importantly, no single combination of sample and assay was able to dependably identify CSFV-inoculated pigs throughout the 4-week course of the study. The results show that effective surveillance for CSFV, especially low virulence strains, will require the use of PCR-based assays for the detection of early infections (<14 days) and antibody-based assays, thereafter. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Detection of serum anti-sperm antibody in infertile couples with dot-immunogold filtration assay (DIGFA)

    International Nuclear Information System (INIS)

    Xie Xiaoxian

    2005-01-01

    Objective: To develop a new method for rapid detection of serum anti-sperm antibody in infertile couples. Methods: Human sperm antigen was prepared from pooled semen specimens of fertile males. Nitro-cellulose membrane was used as solid-phase carrier of the antigen. Colloidal gold pellet combined goat anti-human IgG was taken as labelled antibody. A dot-immunogold filtration assay system was established for test of serum anti-human sperm antibody. Serum specimens from 137 infertile couples were tested and the result compared with flat from ELISA. Results: The human sperm antigen would react with the anti-sperm antibody in the tested serum over the cellulose membrane through filtration and the result could be read with naked eye within 6 minutes. In this study of 137 infertile coupled, the anti-sperm antibody was positive in 21.9% of the female serum specimens and 13.19% of the males. Compared with the result from ELISA, the consistency rate was 96.1%. The sensitivity of the assay was 90.2% and specificity was 95.4%. The p reparation was stable after 6 months refrigerator storage. Conclusion: This newly developed DIGFA is very adequate for rap id detection of anti-sperm antibody and deserves popularization. (authors)

  9. Assessment of sensitivity and specificity of first, second, and third generation EIA for the detection of antibodies to HIV-1 in oral fluid.

    Science.gov (United States)

    Louie, Brian; Lei, John; Liska, Sally; Dowling, Teri; Pandori, Mark W

    2009-07-01

    The performances of three blood-based immunoassays test kits were compared with regard to their ability to detect HIV-1 antibody in oral fluid. It was found that these three kits differ in their ability to detect HIV-1 antibody. Notably, a third generation EIA which has been shown to possess superior sensitivity for antibody detection in plasma appears to possess no sensitivity advantage for detecting HIV-1 antibody in oral fluid.

  10. [Detection of anti-Leptospira antibodies in sera of patients in the latex agglutination test].

    Science.gov (United States)

    Volina, E G; Sarukhanova, L E; Iashina, N V; Prokopov, N I; Shkarlat, P E; Barysheva, I V

    2001-01-01

    The results of the preliminary evaluation of the sensitivity and specificity of the newly developed diagnostic test based on the determination of genus-specific antibodies to leptospires in the latex agglutination test, are presented. This test makes it possible to detect anti-Leptospira antibodies of any serogroup. The advantages of the developed test have been determined.

  11. Evaluation of the Chagas Stat-Paktm Assay for Detection of Trypanosoma cruzi Antibodies in Wildlife Reservoirs

    Science.gov (United States)

    Yabsley, Michael J.; Brown, Emily L.; Roellig, Dawn M.

    2010-01-01

    An immunochromatographic assay (Chagas Stat-Pak™) was evaluated for the detection of Trypanosoma cruzi antibodies in 4 species of wildlife reservoirs. Antibodies to T. cruzi were detected in raccoons (Procyon lotor) (naturally and experimentally infected) and degus (Octodon degu) (experimentally-infected) using the Chagas Stat-Pak. In naturally exposed wild raccoons, the Chagas Stat-Pak had a sensitivity and specificity of 66.7–80.0% and 96.3%, respectively. Compared with indirect immunofluorescent antibody assay results, serocon-version as determined by Chagas Stat-Pak was delayed for experimentally infected raccoons, but occurred sooner in experimentally infected degus. The Chagas Stat-Pak did not detect antibodies in naturally or experimentally infected Virginia opossums (Didelphis virginiana) or in experimentally infected short-tailed opossums (Monodelphis domestica). These data suggest that the Chagas Stat-Pak might be useful in field studies of raccoons and degus when samples would not be available for more-conventional serologic assays. Because this assay did not work on either species of marsupial, the applicability of the assay should be examined before it is used in other wild species. PMID:19016578

  12. Evaluation of a monoclonal antibody able to detect live Listeria monocytogenes and Listeria innocua

    DEFF Research Database (Denmark)

    Sølve, Marianne; Boel, Jeppe; Nørrung, Birgit

    2000-01-01

    A monoclonal Listeria antibody, designated B4, was evaluated. The ability of the antibody to bind to viable bacteria belonging to Listeria spp, compared to bacteria of the same species killed by beat treatment, acid or base treatment, sanitizers, and irradiation was examined. The antibody was found...... to react with viable L. monocytogenes and L. innocua, but not with heat-killed (72 degrees C, 5 min) strains of these organisms. When L. monocytogenes and L. innocua were killed by methods other than heat treatment, it was ambiguous whether the antibody detected the organism or not. It was concluded...... that the B4 antibody has potential to be used in an immune capture step to capture live L, monocytogenes and L. innocua from foods prior to identification of L. monocytogenes by polymerase chain reaction (PCR)....

  13. A Secondary Antibody-Detecting Molecular Weight Marker with Mouse and Rabbit IgG Fc Linear Epitopes for Western Blot Analysis.

    Science.gov (United States)

    Lin, Wen-Wei; Chen, I-Ju; Cheng, Ta-Chun; Tung, Yi-Ching; Chu, Pei-Yu; Chuang, Chih-Hung; Hsieh, Yuan-Chin; Huang, Chien-Chiao; Wang, Yeng-Tseng; Kao, Chien-Han; Roffler, Steve R; Cheng, Tian-Lu

    2016-01-01

    Molecular weight markers that can tolerate denaturing conditions and be auto-detected by secondary antibodies offer great efficacy and convenience for Western Blotting. Here, we describe M&R LE protein markers which contain linear epitopes derived from the heavy chain constant regions of mouse and rabbit immunoglobulin G (IgG Fc LE). These markers can be directly recognized and stained by a wide range of anti-mouse and anti-rabbit secondary antibodies. We selected three mouse (M1, M2 and M3) linear IgG1 and three rabbit (R1, R2 and R3) linear IgG heavy chain epitope candidates based on their respective crystal structures. Western blot analysis indicated that M2 and R2 linear epitopes are effectively recognized by anti-mouse and anti-rabbit secondary antibodies, respectively. We fused the M2 and R2 epitopes (M&R LE) and incorporated the polypeptide in a range of 15-120 kDa auto-detecting markers (M&R LE protein marker). The M&R LE protein marker can be auto-detected by anti-mouse and anti-rabbit IgG secondary antibodies in standard immunoblots. Linear regression analysis of the M&R LE protein marker plotted as gel mobility versus the log of the marker molecular weights revealed good linearity with a correlation coefficient R2 value of 0.9965, indicating that the M&R LE protein marker displays high accuracy for determining protein molecular weights. This accurate, regular and auto-detected M&R LE protein marker may provide a simple, efficient and economical tool for protein analysis.

  14. Sensitive radioimmunoassay for detection of antibodies to recombinant human interferon-alpha A

    International Nuclear Information System (INIS)

    Palleroni, A.V.; Trown, P.W.

    1986-01-01

    A radioimmunoassay (RIA) for the detection of antibodies to recombinant human leukocyte interferon A (rHuIFN-alpha A) in human serum has been developed and validated against the standard antiviral neutralization bioassay (ANB). The assay measures the binding of 125 I-labeled rHuIFN-alpha A to immunoglobulins in serum. Aliquots of patients' sera are incubated with 125 I-rHuIFN-alpha A and the complexes formed between antibodies in the sera and the 125 I-rHuIFN-alpha A are precipitated with goat anti-human IgG serum. The radioactivity in the immune precipitate is a measure of the quantity of antibody (if present) in the serum. The sensitivity of this RIA is 5 ng of IgG/ml of serum

  15. Improved detection of Pneumocystis carinii by an immunofluorescence technique using monoclonal antibodies

    DEFF Research Database (Denmark)

    Orholm, M; Holten-Andersen, W; Lundgren, Jens Dilling

    1990-01-01

    To assess whether a recently developed indirect immunofluorescent stain using monoclonal antibodies was more sensitive in detecting Pneumocystis carinii than the combination of Giemsa and methenamine silver nitrate stains which has routinely been used in the laboratory, 88 lavage fluid specimens...... silver nitrate and toluidine blue O. Immunofluorescence using the monoclonal antibodies from the NIH was significantly more sensitive than any other single staining method and than the combination of Giemsa and methenamine silver nitrate staining. The study also showed that the cytospin centrifuge...

  16. Referencing cross-reactivity of detection antibodies for protein array experiments [version 1; referees: 1 approved, 2 approved with reservations

    Directory of Open Access Journals (Sweden)

    Darragh Lemass

    2016-01-01

    Full Text Available Protein arrays are frequently used to profile antibody repertoires in humans and animals. High-throughput protein array characterisation of complex antibody repertoires requires a platform-dependent, lot-to-lot validation of secondary detection antibodies. This article details the validation of an affinity-isolated anti-chicken IgY antibody produced in rabbit and a goat anti-rabbit IgG antibody conjugated with alkaline phosphatase using protein arrays consisting of 7,390 distinct human proteins. Probing protein arrays with secondary antibodies in absence of chicken serum revealed non-specific binding to 61 distinct human proteins. The cross-reactivity of the tested secondary detection antibodies points towards the necessity of platform-specific antibody characterisation studies for all secondary immunoreagents. Secondary antibody characterisation using protein arrays enables generation of reference lists of cross-reactive proteins, which can be then excluded from analysis in follow-up experiments. Furthermore, making such cross-reactivity lists accessible to the wider research community may help to interpret data generated by the same antibodies in applications not related to protein arrays such as immunoprecipitation, Western blots or other immunoassays.

  17. Emerging Technologies and Generic Assays for the Detection of Anti-Drug Antibodies

    Directory of Open Access Journals (Sweden)

    Michael A. Partridge

    2016-01-01

    Full Text Available Anti-drug antibodies induced by biologic therapeutics often impact drug pharmacokinetics, pharmacodynamics response, clinical efficacy, and patient safety. It is critical to assess the immunogenicity risk of potential biotherapeutics in producing neutralizing and nonneutralizing anti-drug antibodies, especially in clinical phases of drug development. Different assay methodologies have been used to detect all anti-drug antibodies, including ELISA, radioimmunoassay, surface plasmon resonance, and electrochemiluminescence-based technologies. The most commonly used method is a bridging assay, performed in an ELISA or on the Meso Scale Discovery platform. In this report, we aim to review the emerging new assay technologies that can complement or address challenges associated with the bridging assay format in screening and confirmation of ADAs. We also summarize generic anti-drug antibody assays that do not require drug-specific reagents for nonclinical studies. These generic assays significantly reduce assay development efforts and, therefore, shorten the assay readiness timeline.

  18. Value of serum TORCH-specific antibody detection in assessment of neonatal jaundice

    Directory of Open Access Journals (Sweden)

    Guang-Hua Dai

    2016-06-01

    Full Text Available Objective: To study the value of serum TORCH-specific antibody detection in assessment of neonatal jaundice. Methods: A total of 70 cases of children with neonatal jaundice were selected as jaundice group, 70 cases of healthy newborn were the control group, and serum serum TORCH-specific antibody content as well as heart function, liver function, kidney function and nerve function indicators were detected. Results: Serum TOX-IgM, RV-IgM, CMV-IgM and HSV-IgM positive rate and content of jaundice group were significantly higher than those of control group; serum CK-MB, cTnI, AST, ALT, Cys-C, RBP, MBP, S100β and NSE content of TORCH-positive children were significantly higher than those of TORCHnegative children, and BDNF, NT-3, NT-4 and NGF content were significantly lower than those of TORCH-negative children; T1WI signal of pallidum MRI of TORCH-positive children was significantly higher than that of TORCH-negative children. Conclusions: Serum TORCHspecific antibodies significantly increase in children with neonatal jaundice and can assess the degree of bilirubin metabolism disorder and the degree of target organ damage.

  19. Human Polyclonal Antibodies Produced through DNA Vaccination of Transchromosomal Cattle Provide Mice with Post-Exposure Protection against Lethal Zaire and Sudan Ebolaviruses.

    Directory of Open Access Journals (Sweden)

    Callie E Bounds

    Full Text Available DNA vaccination of transchromosomal bovines (TcBs with DNA vaccines expressing the codon-optimized (co glycoprotein (GP genes of Ebola virus (EBOV and Sudan virus (SUDV produce fully human polyclonal antibodies (pAbs that recognize both viruses and demonstrate robust neutralizing activity. Each TcB was vaccinated by intramuscular electroporation (IM-EP a total of four times and at each administration received 10 mg of the EBOV-GPco DNA vaccine and 10 mg of the SUDV-GPco DNA vaccine at two sites on the left and right sides, respectively. After two vaccinations, robust antibody responses (titers > 1000 were detected by ELISA against whole irradiated EBOV or SUDV and recombinant EBOV-GP or SUDV-GP (rGP antigens, with higher titers observed for the rGP antigens. Strong, virus neutralizing antibody responses (titers >1000 were detected after three vaccinations when measured by vesicular stomatitis virus-based pseudovirion neutralization assay (PsVNA. Maximal neutralizing antibody responses were identified by traditional plaque reduction neutralization tests (PRNT after four vaccinations. Neutralizing activity of human immunoglobulins (IgG purified from TcB plasma collected after three vaccinations and injected intraperitoneally (IP into mice at a 100 mg/kg dose was detected in the serum by PsVNA up to 14 days after administration. Passive transfer by IP injection of the purified IgG (100 mg/kg to groups of BALB/c mice one day after IP challenge with mouse adapted (ma EBOV resulted in 80% protection while all mice treated with non-specific pAbs succumbed. Similarly, interferon receptor 1 knockout (IFNAR(-/- mice receiving the purified IgG (100 mg/kg by IP injection one day after IP challenge with wild type SUDV resulted in 89% survival. These results are the first to demonstrate that filovirus GP DNA vaccines administered to TcBs by IM-EP can elicit neutralizing antibodies that provide post-exposure protection. Additionally, these data describe

  20. Detection of Hepatitis C core antibody by dual-affinity yeast chimera and smartphone-based electrochemical sensing.

    Science.gov (United States)

    Aronoff-Spencer, Eliah; Venkatesh, A G; Sun, Alex; Brickner, Howard; Looney, David; Hall, Drew A

    2016-12-15

    Yeast cell lines were genetically engineered to display Hepatitis C virus (HCV) core antigen linked to gold binding peptide (GBP) as a dual-affinity biobrick chimera. These multifunctional yeast cells adhere to the gold sensor surface while simultaneously acting as a "renewable" capture reagent for anti-HCV core antibody. This streamlined functionalization and detection strategy removes the need for traditional purification and immobilization techniques. With this biobrick construct, both optical and electrochemical immunoassays were developed. The optical immunoassays demonstrated detection of anti-HCV core antibody down to 12.3pM concentrations while the electrochemical assay demonstrated higher binding constants and dynamic range. The electrochemical format and a custom, low-cost smartphone-based potentiostat ($20 USD) yielded comparable results to assays performed on a state-of-the-art electrochemical workstation. We propose this combination of synthetic biology and scalable, point-of-care sensing has potential to provide low-cost, cutting edge diagnostic capability for many pathogens in a variety of settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Direct immobilization of antibodies on Zn-doped Fe_3O_4 nanoclusters for detection of pathogenic bacteria

    International Nuclear Information System (INIS)

    Pal, Monalisa; Lee, Sanghee; Kwon, Donghoon; Hwang, Jeongin; Lee, Hyeonjeong; Hwang, Seokyung; Jeon, Sangmin

    2017-01-01

    Zinc-doped magnetic nanoclusters (Zn-MNCs) were synthesized and used to detect pathogenic bacteria in milk. Hydrothermally synthesized Zn-MNCs exhibited stronger magnetic properties than pure MNCs, which facilitated the magnetic separation from the sample using a permanent magnet. The presence of accessible Zn sites allows the direct immobilization of half-fragmented antibodies over Zn-MNCs through strong Zn−S bonds and prevents the tedious multiple steps of molecular functionalization or coating with costly noble metals prior to conjugation with an antibody. After the capture and magnetic separation of Salmonella in milk using the antibody-functionalized Zn-MNCs, the concentration of bacteria was determined with a portable ATP luminometer and the detection limit was found to be 10 CFU/mL. - Highlights: • Zn-doped Fe_3O_4 nanoclusters (Zn-MNCs) were synthesized by hydrothermal method. • Antibodies were directly immobilized over Zn-MNCs through strong Zn–S_t_h_i_o_l bonds. • Higher magnetization of Zn-MNCs than pure MNCs facilitates the magnetic separation. • Detection limit of pathogenic bacteria in milk was found to be 10 cfu/mL. • Cost effective, sensitive and selective detection of bacteria.

  2. Detection of Chlamydophila psittaci antibodies from captive birds at the Ninoy Aquino Parks and Wildlife Nature Center, Quezon City, Philippines.

    Science.gov (United States)

    Maluping, Ramon P; Oronan, Rey B; Toledo, Steven U

    2007-01-01

    The present study was undertaken to detect the presence of Chlamydophila psittaci antibodies in captive birds at the Wildlife Rescue Center, Ninoy Aquino Parks and Wildlife Nature Center, Quezon City, Philippines. Blood was collected from 36 birds of different species and the presence of antibodies against C. psittaci was detected using an ELISA-based test kit. 25% of the samples demonstrated antibodies against C. psittaci. The results of this study confirmed the presence of C. psittaci antibodies among the captive birds examined.

  3. Detection of human cancer in an animal model using radio-labelled tumour-associated monoclonal antibodies

    International Nuclear Information System (INIS)

    Epenetos, A.A.; Arklie, J.; Knowles, R.W.; Bodmer, W.F.

    1982-01-01

    Monoclonal antibodies to epithelial-cell antigenic determinants, labelled with 123 I and 125 I, were administered parenterally to immunodeficient mice bearing human tumours derived from a human cancer cell line. Anterior, posterior and lateral radioscans of the body were taken with a gamma scintillation camera at various times from immediately to 65 days after injection. Visual displays of the images were processed by standard computer techniques. The model used a human colon-cancer cell line, HT29, and the monoclonal antibody, AUAl, which is specific to an epithelial proliferating antigen. Tumour detection was achieved in all the mice. The smallest tumour detectable appeared to be about 1 mm in diameter. The degree of antibody uptake in a tumour depended on its size and the blood supply of its surrounding tissues. (author)

  4. Detection and specifity of class specific antibodies to whole bacteria cells using a solid phase radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Czerkinsky, C.; Rees, A.S.; Bergimeier, L.A.; Challacombe, S.J. (Guy' s Hospital Medical and Dental Schools, London (UK))

    1983-07-01

    A solid phase radioimmunoassay has been developed which can be used for the detection of isotype specific antibodies to whole bacteria and other particulate antigens, and is applicable to a variety of species. Bacteria are bound to the solid phase by the use either of antibodies, or of methyl glyoxal. Both methods result in a sensitive and reproducible assay, and bacteria do not appear to desorb from the solid phase. The specificity of antibodies to whole bacteria was examined by absorption of antisera with various species of bacteria and retesting, or by determining the binding of antisera to various bacteria bound to the solid phase. Both methods revealed specificity for the bacteria examined. Inhibition studies showed that antibodies to Streptococcus mutans whole cells could be inhibited by purified cell surface antigens glucosyltransferase and antigen I/II, but only minimally by lipoteichoic acid, c polysaccharide or dextran. In murine antisera antibodies of the IgG, IgM, and IgA classes could be detected at amounts of less than 1 ng/ml.

  5. Detection of metastatic tumor in normal-sized retroperitoneal lymph nodes by monoclonal-antibody imaging

    International Nuclear Information System (INIS)

    Moldofsky, P.J.; Sears, H.F.; Mulhern, C.B. Jr.; Hammond, N.D.; Powe, J.; Gatenby, R.A.; Steplewski, Z.; Koprowski, H.

    1984-01-01

    Detection of metastatic colon carcinoma is reported in retroperitoneal lymph nodes that were visible but normal in size (less than 1 cm) and number on CT scanning and at surgery. A case history is presented of 1 of 27 patients with colon carcinoma, metastatic or primary, evaluated with intravenously administered, radiolabeled monoclonal-antibody fragments and subsequent nuclear medicine imaging. Images of /sup 99m/Tc-labeled red cells corresponding to each [ 131 I]antibody view of the abdomen were obtained as a control, to avoid interpretation of simple blood-pool radioactivity as specific localization of antibody on tumor. Antibody images were evaluated both without and with computer blood-pool image substraction. Directed to the level of the left renal hilum by the antibody scan, the surgeon removed the largest palpable node, which measured slightly less than 1 cm in diameter and was not palpably or visibly abnormal to the surgeon until it was removed and sectioned. Pathological evaluation of frozen and permanent sections revealed microscopic foci of adenocarcinoma consistent with a colonic primary tumor. Immunoperoxidase staining for the 1083-17-1A colorectal-carcinoma antigen demonstrated the presence of the antigen in the lymph node. As a result of the detection of this metastasis outside the liver, the patient did not receive the planned hepatic-artery chemotherapy pump but instead received intravenous chemotherapy

  6. Radioimmunoassay for detection of VP1 specific neutralizing antibodies of foot and mouse disease virus

    International Nuclear Information System (INIS)

    Patzer, E.J.; Jackson, M.L.; Moore, D.M.

    1985-01-01

    A solid-phase radioimmunoassay was developed for the detection of antibodies against a specific region of the VP1 protein of the A24 and O1 serotypes of foot and mouth disease virus. The antibody titers from the radioimmunoassay showed a positive correlation with neutralizing antibody titers determined by a mouse protection assay. The specificity of the assay resides in the peptide used as antigen. The assay is rapid, reproducible and does not require the use of whole virions. (orig.)

  7. Antigen spot test (AST): a highly sensitive assay for the detection of antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Herbrink, P; van Bussel, F J; Warnaar, S O [Rijksuniversiteit Leiden (Netherlands)

    1982-02-12

    A method is described for detection of antibodies by means of nitrocellulose or diazobenzyloxymethyl (DBM) paper on which various antigens have been spotted. The sensitivity of this antigen spot test (AST) is comparable with that of RIA and ELISA. The method requires only nanogram amounts of antigen. Since a variety of antigens can be spotted on a single piece of nitrocellulose or DBM paper, this antigen spot test is especially useful for specificity controls on antibodies.

  8. Toxoplasmosis serology: an efficient hemagglutination procedure to detect IgG and IgM antibodies

    Directory of Open Access Journals (Sweden)

    M.E. Camargo

    1989-08-01

    Full Text Available In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

  9. Effect of serum heat-inactivation and dilution on detection of anti-WNV antibodies in mice by West Nile virus E-protein microsphere immunoassay.

    Directory of Open Access Journals (Sweden)

    Madhuri Namekar

    Full Text Available Immunopathogenesis studies employing West Nile virus (WNV mice model are important for the development of antivirals and vaccines against WNV. Since antibodies produced in mice early during WNV infection are essential for clearing virus from the periphery, it is important to detect early and persistent anti-WNV antibodies. ELISA and plaque reduction neutralization tests are traditionally used for detection of anti-WNV antibodies and WNV-neutralizing antibodies, respectively. Although these assays are sensitive and specific, they are expensive and time consuming. Microsphere immunoassays (MIA are sensitive, specific, allow for high throughput, are cost effective, require less time to perform than other methods, and require low serum volumes. Several assay parameters such as serum heat-inactivation (HI and dilution can alter WNV MIA sensitivity. We examined the effect of these parameters on WNV E-protein MIA (WNV E-MIA for the enhanced detection of anti-WNV IgM and IgG antibodies. WNV E-MIA was conducted using serial dilutions of HI and non-HI (NHI serum collected at various time points from mice inoculated with WNV. HI significantly enhanced detection of IgM and IgG antibodies as compared to NHI serum. WNV IgM and IgG antibodies in HI sera were detected earlier at day 3 and IgM antibodies persisted up to day 24 after infection. HI serum at 1∶20 dilution was found to be optimal for detection of both IgM and IgG antibodies as compared to higher-serum dilutions. Further, addition of exogenous complement to the HI serum decreased the WNV E-MIA sensitivity. These results suggest that serum-HI and optimal dilution enhance WNV E-MIA sensitivity by eliminating the complement interference, thereby detecting low-titer anti-WNV antibodies during early and late phases of infection. This improved MIA can also be readily employed for detection of low-titer antibodies for detection of other infectious agents and host proteins.

  10. The clinical significance of detecting serum glutamic acid decarboxylase antibody (GAD), C-peptide and insulin in diabetics

    International Nuclear Information System (INIS)

    Zheng Tingliang; Zhang Jinchi; Yao Yingfei; Chen Linxing; Huang Hua

    2005-01-01

    Objective: To explore the clinical significance of detecting serum glutamic acid decarboxylase (GAD) antibody, C-peptide (CP) and insulin (INS) in the classification of diabetic patients. Methods: Serum GAD antibody, CP and INS concentration were determined with RIA in 27 patients with type 1 diabetes mellitus (DM1) and 49 patients with type 2 diabetes mellitus (DM2). Sugar-electrode-method was used to detect the concentrations of fasting plasma glucose (FPG) in these patients. Results: The positive rate of GAD antibody in DM1 patients (66.7%) were significantly higher than that in DM2 group (8.2%) (P<0.01), The levels of CP and INS were lower in DM1 group than those in DM2 group as well (P<0.01). Conclusion: GAD antibody is a valuable marker to predict the impairment of β-cell GAD antibody levels, together with CP /FPG and INS/FPG ratios, might be useful in determining the type of DM and guiding the therapy. (authors)

  11. Detection of specific IgA antibodies against a novel deamidated 8-Mer gliadin peptide in blood plasma samples from celiac patients.

    Directory of Open Access Journals (Sweden)

    Sara Vallejo-Diez

    Full Text Available We studied whether celiac disease (CD patients produce antibodies against a novel gliadin peptide specifically generated in the duodenum of CD patients by a previously described pattern of CD-specific duodenal proteases. Fingerprinting and ion-trap mass spectrometry of CD-specific duodenal gliadin-degrading protease pattern revealed a new 8-mer gliadin-derived peptide. An ELISA against synthetic deamidated 8-mer peptides (DGP 8-mer was used to study the presence of IgA anti-DGP 8-mer antibodies in plasma samples from 81 children (31 active CD patients (aCD, 17 CD patients on a gluten-free diet (GFD, 10 healthy controls (C and 23 patients with other gastrointestinal pathology (GP and 101 adults (16 aCD, 12 GFD, 27 C and 46 GP-patients. Deamidation of the 8-mer peptide significantly increased the reactivity of the IgA antibodies from CD patients against the peptide. Significant IgA anti-DGP 8-mer antibodies levels were detected in 93.5% of aCD-, 11.8% of GFD- and 4.3% of GP-patients in children. In adults, antibodies were detected in 81.3% of aCD-patients and 8.3% of GFD-patients while were absent in 100% of C- and GP-patients. Duodenal CD-specific gliadin degrading proteases release an 8-mer gliadin peptide that once deamidated is an antigen for specific IgA antibodies in CD patients which may provide a new accurate diagnostic tool in CD.

  12. Novel Phospholipid-Protein Conjugates Allow Improved Detection of Antibodies in Patients with Autoimmune Diseases

    DEFF Research Database (Denmark)

    Samuelsen, Simone V; Maity, Arindam; Nybo, Mads

    2016-01-01

    Reliable measurement of clinically relevant autoimmune antibodies toward phospholipid-protein conjugates is highly desirable in research and clinical assays. To date, the development in this field has been limited to the use of natural heterogeneous antigens. However, this approach does not take ...... on the correlation of detected autoantibodies with disease activity and manifestations. This confirms the crucial importance of antigens' composition on research and diagnostic assays, and opens up exciting perspectives for synthetic antigens in future studies of autoimmunity.......Reliable measurement of clinically relevant autoimmune antibodies toward phospholipid-protein conjugates is highly desirable in research and clinical assays. To date, the development in this field has been limited to the use of natural heterogeneous antigens. However, this approach does not take...... structural features of biologically active antigens into account and leads to low reliability and poor scientific test value. Here we describe novel phospholipid-protein conjugates for specific detection of human autoimmune antibodies. Our synthetic approach includes mild oxidation of synthetic phospholipid...

  13. The development and applications of polyclonal and monoclonal antibodies for the detection of illicit drugs in saliva samples

    OpenAIRE

    Fanning, Lorna M.

    2002-01-01

    Anti-tetrahydrocannabinol (THC), anti-cocaine and anti-morphine polyclonal antibodies were produced. These antibodies were successfully applied to an ELISA format for the detection of THC, cocaine, and morphine in saliva samples. Monoclonal antibodies against amphetamine and its derivatives were produced using two different conjugates, amphetamine-bovine serum albumin and methamphetaminebovine serum albumin. Two successful clones were produced, and the antibodies were applied to an ELISA ...

  14. Autoantibodies to the Rpp25 component of the Th/To complex are the most common antibodies in patients with systemic sclerosis without antibodies detectable by widely available commercial tests.

    Science.gov (United States)

    Mahler, Michael; Satoh, Minoru; Hudson, Marie; Baron, Murray; Chan, Jason Y F; Chan, Edward K L; Wick, James; Fritzler, Marvin J

    2014-07-01

    Antinuclear antibodies (ANA) occur in up to 95% of patients with systemic sclerosis (SSc). In most, SSc-associated antibodies are detected (i.e., centromere, topoisomerase I, RNA polymerase III, PM/Scl, Ro52/TRIM21, and U1RNP). Ribonuclease P protein subunit p25, (Rpp25) is an autoantigenic component of the Th/To complex. The contribution of anti-Th/To and anti-Rpp25 antibodies to ANA positivity in patients with SSc remains unknown. Sera from 873 patients with SSc were tested for ANA, and SSc-associated antibodies were measured. Samples without antibodies to extractable nuclear antigens (ENA; n = 53, ANA+/ENA-), were analyzed by immunoprecipitation (IP) and metabolically labeled proteins and for anti-Rpp25 antibodies (n = 50) by a chemiluminescent immunoassay (CLIA) and Rpp25 ELISA. Anti-Th/To antibodies occurred in 19/53 (36%), as determined by IP, and were the most common autoantibody in ANA+/ENA- SSc. Of those samples, 50/53 were available for additional testing by CLIA and ELISA. Anti-Rpp25 antibodies were detected in 12 (24% CLIA) or 10 (20% ELISA) of 50 patients. Receiver-operating characteristic curve analysis showed similar discrimination between Th/To IP-positive (n = 19) and -negative samples (n = 31) by CLIA and ELISA (area under the curve 0.90 vs 0.87; p = 0.6691). The positive percent agreement between IP and CLIA or ELISA was 12/19 (63.2%, 95% CI 38.4-83.7%) or 10/19 (52.6%, 95% CI 73.3-94.2%), respectively. Negative percent agreement was 100% for both assays. Autoantibodies to the Th/To autoantigen are important in patients with SSc who have been considered negative for SSc-specific or SSc-associated antibodies by widely available commercial assays. Rpp25 can be considered a major target of anti-Th/To antibodies. Assays detecting anti-Th/To and anti-Rpp25 antibodies may be important in SSc.

  15. Rapid solid-phase radioimmunoassay for detection of equine infectious anemia viral antigen and antibodies: parameters involved in standardization

    International Nuclear Information System (INIS)

    Horenstein, A.L.; Feinstein, R.E.

    1985-01-01

    Solid-phase radioimmunoassays (SPRIA) are described for the detection of equine infectious anemia (EIA) viral antigen and antibodies. Protein-antigen P29 currently used in the agar-gel immunodiffusion (AGID) test was used as antigen in the SPRIA. The specificity of the reaction was assessed by inhibition with the antigen. The reaction of immune serum against EIA-virus antigen adsorbed to the wells, was completely inhibited by the antigen in solution. This property was applied in an indirect competitive SPRIA for the detection of viral protein P29. The detection threshold of the SPRIA for EIA virus protein was about 5 ng and about 1 ng of antibody can be detected. The assay is rapid, specific and sensitive and allows the testing of multiple serum samples with the advantage of employing a single secondary labelled antibody. (orig.)

  16. Development of a dipstick assay for detection of Leishmania-specific canine antibodies

    NARCIS (Netherlands)

    Schallig, Henk D. F. H.; Cardoso, Luís; Hommers, Marieke; Kroon, Nel; Belling, Guus; Rodrigues, Manuela; Semião-Santos, Saul J.; Vetter, Hans

    2004-01-01

    A dipstick assay, based on Leishmania infantum antigen, for the rapid detection of Leishmania-specific antibodies in canine serum samples was developed and evaluated. After determination of optimal dipstick test conditions, test performance was compared with two existing serological tests, i.e., the

  17. Field evaluation of a fast anti-Leishmania antibody detection assay in Ethiopia

    NARCIS (Netherlands)

    Hailu, A.; Schoone, G. J.; Diro, E.; Tesfaye, A.; Techane, Y.; Tefera, T.; Assefa, Y.; Genetu, A.; Kebede, Y.; Kebede, T.; Schallig, H. D. F. H.

    2006-01-01

    A fast agglutination screening test (FAST) for the detection of Leishmania antibodies in human serum samples was evaluated under harsh field conditions in northern Ethiopia. Test performance was compared with a standard serological test, namely the direct agglutination test (DAT), and with

  18. COMPARISONS OF ELISA AND WESTERN BLOT ASSAYS FOR DETECTION OF CRYPTOSPORIDIUM ANTIBODY

    Science.gov (United States)

    A seroprevalence survey was conducted using ELISA and Western blot (WB) assays for antibody to three Cryptosporidium antigens on 380 blood donors in Jackson County, Oregon. The purpose was to determine if either assay could detect serological evidence of an outbreak which occurre...

  19. Self-paired monoclonal antibody lateral flow immunoassay strip for rapid detection of Acidovorax avenae subsp. citrulli.

    Science.gov (United States)

    Zeng, Haijuan; Guo, Wenbo; Liang, Beibei; Li, Jianwu; Zhai, Xuzhao; Song, Chunmei; Zhao, Wenjun; Fan, Enguo; Liu, Qing

    2016-09-01

    We screened a highly specific monoclonal antibody (McAb), named 6D, against Acidovorax avenae subsp. citrulli (Aac). Single McAb 6D was used as both nanogold-labeled antibody and test antibody to develop a single self-paired colloidal gold immunochromatographic test strip (Sa-GICS). The detection limit achieved using the Sa-GICS approach was 10(5) CFU/mL, with a result that can be observed by the naked eye within 10 min. Moreover, Sa-GICS can detect eight strains of Aac and display no cross-reactions with other pathogenic plant microorganisms. Artificial contamination experiments demonstrated that Sa-GICS would not be affected by impurities in the leaves or stems of the plants and were consistent with the PCR results. This is the first report on the development of a colloidal gold immunoassay strip with self-paired single McAb for the rapid detection of Aac. Graphical Abstract Schematic representation of the test strip.

  20. Use of Monoclonal Antibodies in the Sensitive Detection and Neutralization of Botulinum Neurotoxin Serotype B

    Directory of Open Access Journals (Sweden)

    Luisa W. Cheng

    2015-11-01

    Full Text Available Botulinum neurotoxins (BoNT are some of nature’s most potent toxins. Due to potential food contamination, and bioterrorism concerns, the development of detection reagents, therapeutics and countermeasures are of urgent interest. Recently, we have developed a sensitive electrochemiluminescent (ECL immunoassay for BoNT/B, using monoclonal antibodies (mAbs MCS6-27 and anti-BoNT/B rabbit polyclonal antibodies as the capture and detector. The ECL assay detected as little as 1 pg/mL BoNT/B in the buffer matrix, surpassing the detection sensitivities of the gold standard mouse bioassays. The ECL assay also allowed detection of BoNT/B in sera matrices of up to 100% sera with negligible matrix effects. This highly-sensitive assay allowed the determination of the biological half-lives of BoNT/B holotoxin in vivo. We further tested the toxin neutralization potential of our monoclonal antibodies using the mouse systemic and oral intoxication models. A combination of mAbs protected mice in both pre- and post-exposure models to lethal doses of BoNT/B. MAbs were capable of increasing survival of animals when administered even 10 h post-intoxication in an oral model, suggesting a likely time for BoNT/B complexes to reach the blood stream. More sensitive detection assays and treatments against BoNT intoxication will greatly enhance efforts to combat botulism.

  1. Sandwich enzyme-linked immunosorbent assay (ELISA) for measuring the concentration of, and detection of antibodies to, Aujeszky's disease virus.

    Science.gov (United States)

    Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z

    1990-01-01

    A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.

  2. Amperometric Immunosensor for Carbofuran Detection Based on MWCNTs/GS-PEI-Au and AuNPs-Antibody Conjugate

    Directory of Open Access Journals (Sweden)

    Xiangyou Wang

    2013-04-01

    Full Text Available In this paper, an amperometric immunosensor for the detection of carbofuran was developed. Firstly, multiwall carbon nanotubes (MWCNTs and graphene sheets-ethyleneimine polymer-Au (GS-PEI-Au nanocomposites were modified onto the surface of a glass carbon electrode (GCE via self-assembly. The nanocomposites can increase the surface area of the GCE to capture a large amount of antibody, as well as produce a synergistic effect in the electrochemical performance. Then the modified electrode was coated with gold nanoparticles-antibody conjugate (AuNPs-Ab and blocked with BSA. The monoclonal antibody against carbofuran was covalently immobilized on the AuNPs with glutathione as a spacer arm. The morphologies of the GS-PEI-Au nanocomposites and the fabrication process of the immunosensor were characterized by X-ray diffraction (XRD, ultraviolet and visible absorption spectroscopy (UV-vis and scanning electron microscopy (SEM, respectively. Under optimal conditions, the immunosensor showed a wide linear range, from 0.5 to 500 ng/mL, with a detection limit of 0.03 ng/mL (S/N = 3. The as-constructed immunosensor exhibited notable performance features such as high specificity, good reproducibility, acceptable stability and regeneration performance. The results are mainly due to the excellent properties of MWCNTs, GS-PEI-Au nanocomposites and the covalent immobilization of Ab with free hapten binding sites for further immunoreaction. It provides a new avenue for amperometric immunosensor fabrication.

  3. Antibodies to biotinylated red blood cells in adults and infants: improved detection, partial characterization, and dependence on red blood cell-biotin dose.

    Science.gov (United States)

    Schmidt, Robert L; Mock, Donald M; Franco, Robert S; Cohen, Robert M; North, Anne K; Cancelas, José A; Geisen, Christof; Strauss, Ronald G; Vlaar, Alexander P; Nalbant, Demet; Widness, John A

    2017-06-01

    Biotin-labeled red blood cells (BioRBCs) are used for in vivo kinetic studies. Because BioRBC dosing occasionally induces antibodies, a sensitive and specific anti-BioRBC detection assay is needed. Aims were to 1) develop a gel card assay to evaluate existing, naturally occurring and BioRBC-induced plasma antibodies, 2) compare gel card and tube agglutination detection results, and 3) test for a relationship of antibody induction and BioRBC dose. Reagent BioRBCs were prepared using sulfo-NHS biotin ranging from densities 18 (BioRBC-18) to 1458 (BioRBC-1458) µg/mL RBCs. Among BioRBC-exposed subjects, gel card and tube agglutination results were concordant in 21 of 22 adults and all 19 infant plasma samples. Gel card antibody detection sensitivity was more than 10-fold greater than tube agglutination. Twelve to 16 weeks after BioRBC exposure, induced anti-antibodies were detected by gel card in three of 26 adults (12%) at reagent densities BioRBC-256 or less, but in none of 41 infants. Importantly, induced anti-BioRBC antibodies were associated with higher BioRBC dose (p = 0.008); no antibodies were detected in 18 subjects who received BioRBC doses less than or equal to BioRBC-18. For noninduced BioRBC antibodies, six of 1125 naïve adults (0.3%) and none of 46 naïve infants demonstrated existing anti-BioRBC antibodies using reagent BioRBC-140 or -162. Existing anti-BioRBCs were all neutralized by biotin compounds, while induced antibodies were not. The gel card assay is more sensitive than the tube agglutination assay. We recommend reagent BioRBC-256 for identifying anti-BioRBCs. Use of a low total RBC biotin label dose (≤ BioRBC-18) may minimize antibody induction. © 2017 AABB.

  4. Three Types of Striational Antibodies in Myasthenia Gravis

    Directory of Open Access Journals (Sweden)

    Shigeaki Suzuki

    2011-01-01

    Full Text Available Myasthenia gravis (MG is caused by antibodies that react mainly with the acetylcholine receptor on the postsynaptic site of the neuromuscular junction. A wide range of clinical presentations and associated features allow MG to be classified into subtypes based on autoantibody status. Striational antibodies, which react with epitopes on the muscle proteins titin, ryanodine receptor (RyR, and Kv1.4, are frequently found in MG patients with late-onset and thymoma. Antititin and anti-RyR antibodies are determined by enzyme-linked immunosorbent assay or immunoblot. More recently, a method for the detection of anti-Kv1.4 autoantibodies has become available, involving 12–15% of all MG patients. The presence of striational antibodies is associated with more severe disease in all MG subgroups. Anti-Kv1.4 antibody is a useful marker for the potential development of lethal autoimmune myocarditis and response to calcineurin inhibitors. Detection of striational antibodies provides more specific and useful clinical information in MG patients.

  5. The detection and specifity of class specific antibodies to whole bacteria cells using a solid phase radioimmunoassay

    International Nuclear Information System (INIS)

    Czerkinsky, C.; Rees, A.S.; Bergimeier, L.A.; Challacombe, S.J.

    1983-01-01

    A solid phase radioimmunoassay has been developed which can be used for the detection of isotype specific antibodies to whole bacteria and other particulate antigens, and is applicable to a variety of species. Bacteria are bound to the solid phase by the use either of antibodies, or of methyl glyoxal. Both methods result in a sensitive and reproducible assay, and bacteria do not appear to desorb from the solid phase. The specificity of antibodies to whole bacteria was examined by absorption of antisera with various species of bacteria and retesting, or by determining the binding of antisera to various bacteria bound to the solid phase. Both methods revealed specificity for the bacteria examined. Inhibition studies showed that antibodies to Streptococcus mutans whole cells could be inhibited by purified cell surface antigens glucosyltransferase and antigen I/II, but only minimally by lipoteichoic acid, c polysaccharide or dextran. In murine antisera antibodies of the IgG, IgM, and IgA classes could be detected at amounts of less than 1 ng/ml. (author)

  6. Detection by radioimmunoassay and enzyme-linked immunosorbent assay of coronavirus antibodies in bovine serum and lacteal secretions.

    Science.gov (United States)

    Rodak, L; Babiuk, L A; Acres, S D

    1982-07-01

    The sensitivity of a radioimmunoassay (RIA), an enzyme-linked immunosorbent assay (ELISA), and a serum neutralization assay (SN) for detecting antibodies to bovine coronavirus in serum and colostrum were compared. Although there proved to be a good correlation among all three assays (r = 0.915 and 0.964 for RIA with SN and ELISA, respectively), RIA and ELISA proved to be at least 10 times more sensitive than neutralization tests. By using these techniques, it was possible to detect a time-dependent decrease in antibody levels in bovine colostrum after parturition. Using ELISA, we demonstrated that 12 of 12 herds in Saskatchewan, and 109 of 110 animals tested, and antibody to bovine coronavirus. There was no elevated antibody response in serum or lacteal secretions of cows vaccinated once or twice with a commercially available modified live rota-coronavirus vaccine. In addition to being more sensitive than SN, ELISA and RIA proved to have other advantages for measuring antibody levels to bovine coronavirus and therefore warrant wider use as tools in diagnostic virology.

  7. Monoclonal antibodies in oncology

    International Nuclear Information System (INIS)

    Chan, S.Y.T.; Sikora, K.

    1986-01-01

    Monoclonal antibodies (MCAs) can be used to differentiate between normal and neoplastic cells and thus exploited for diagnostic and, ultimately, therapeutic gain. The evidence for the existence of human tumour antigens is reviewed. Several areas of diagnosis are already benefiting from the application of the monoclonal technology. Immunohistology can help the pathologist with difficult diagnostic problems. New classifications of lymphoma and leukaemia can be based on specific surface molecules. Similarly, the detection of shed tumour antigens is already established as part of the routine assessment of many patients with common solid tumours. Isotopically labeled monoclonal antibodies have been used to localise primary and metastatic tumours. The use of antibodies in this way is not only a promising diagnostic tool but also the first step in studying the possibility of arming antibodies to provide therapeutic agents. Such trials are currently in progress. (Auth.)

  8. Effects of blood contamination of cerebrospinal fluid on results of indirect fluorescent antibody tests for detection of antibodies against Sarcocystis neurona and Neospora hughesi.

    Science.gov (United States)

    Finno, Carrie J; Packham, Andrea E; David Wilson, W; Gardner, Ian A; Conrad, Patricia A; Pusterla, Nicola

    2007-05-01

    The purpose of this study was to determine the effect of blood contamination of cerebrospinal fluid (CSF) on the results of indirect fluorescent antibody tests (IFATs) for Sarcocystis neurona and Neospora hughesi. The in vitro study used antibody-negative CSF collected from non-neurologic horses immediately after euthanasia and blood samples from 40 healthy horses that had a range of IFAT antibody titers against S. neurona and N. hughesi. Serial dilutions of whole blood were made in seronegative CSF to generate blood-contaminated CSF with red blood cell (RBC) concentrations ranging from 10 to 100,000 RBCs/microl. The blood-contaminated CSF samples were then tested for antibodies against both pathogens using IFAT. Blood contamination of CSF had no detectable effect on IFAT results for S. neurona or N. hughesi at any serologic titer when the RBC concentration in CSF was or=5) for S. neurona and N. hughesi were detected only when the corresponding serum titers were >or=160 and >or=80, respectively. The IFAT performed on CSF is reliable for testing horses for equine protozoal myeloencephalitis caused by S. neurona or N. hughesi, even when blood contamination causes the RBC concentration in CSF to be up to 10,000 RBCs/microl.

  9. A phage-displayed chicken single-chain antibody fused to alkaline phosphatase detects Fusarium pathogens and their presence in cereal grains

    International Nuclear Information System (INIS)

    Hu, Zu-Quan; Li, He-Ping; Zhang, Jing-Bo; Huang, Tao; Liu, Jin-Long; Xue, Sheng; Wu, Ai-Bo; Liao, Yu-Cai

    2013-01-01

    Graphical abstract: A phage-displayed chicken scFv antibody, FvSG7, binds on the surface antigen of conidiospores and the mycelia of F. verticillioides. Its fusion with alkaline phosphatase (AP) through a 218 linker displayed a 4-fold higher affinity compared with the parent scFv antibody and efficiently detected toxigenic Fusarium pathogens in cereal grains. Highlights: ► Generation of a highly reactive scFv antibody against F. verticillioides. ► Localization of the antibody binding to the surface target of F. verticillioides. ► Expression of the antibody–alkaline phosphatase (AP) fusion linked by a 218 linker. ► The antibody–AP fusion has a higher affinity than the parental antibody. ► The antibody–AP fusion detects toxigenic Fusarium pathogens in cereal grains. -- Abstract: Fusarium and its poisonous mycotoxins are distributed worldwide and are of particular interest in agriculture and food safety. A simple analytical method to detect pathogens is essential for forecasting diseases and controlling mycotoxins. This article describes a proposed method for convenient and sensitive detection of Fusarium pathogens that uses the fusion of single-chain variable fragment (scFv) and alkaline phosphatase (AP). A highly reactive scFv antibody specific to soluble cell wall-bound proteins (SCWPs) of F. verticillioides was selected from an immunized chicken phagemid library by phage display. The antibody was verified to bind on the surface of ungerminated conidiospores and mycelia of F. verticillioides. The scFv–AP fusion was constructed, and soluble expression in bacteria was confirmed. Both the antibody properties and enzymatic activity were retained, and the antigen-binding capacity of the fusion was enhanced by the addition of a linker. Surface plasmon resonance measurements confirmed that the fusion displayed 4-fold higher affinity compared with the fusion's parental scFv antibody. Immunoblot analyses showed that the fusion had good binding capacity to

  10. A phage-displayed chicken single-chain antibody fused to alkaline phosphatase detects Fusarium pathogens and their presence in cereal grains

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Zu-Quan [Molecular Biotechnology Laboratory of Triticeae Crops, Huazhong Agricultural University, Wuhan 430070 (China); Li, He-Ping [Molecular Biotechnology Laboratory of Triticeae Crops, Huazhong Agricultural University, Wuhan 430070 (China); College of Life Science and Technology, Huazhong Agricultural University, Wuhan 430070 (China); Zhang, Jing-Bo [Molecular Biotechnology Laboratory of Triticeae Crops, Huazhong Agricultural University, Wuhan 430070 (China); College of Plant Science and Technology, Huazhong Agricultural University, Wuhan 430070 (China); Huang, Tao [Molecular Biotechnology Laboratory of Triticeae Crops, Huazhong Agricultural University, Wuhan 430070 (China); College of Life Science and Technology, Huazhong Agricultural University, Wuhan 430070 (China); Liu, Jin-Long; Xue, Sheng [Molecular Biotechnology Laboratory of Triticeae Crops, Huazhong Agricultural University, Wuhan 430070 (China); Wu, Ai-Bo [Institute for Agri-food Standards and Testing Technology, Laboratory of Quality and Safety Risk Assessment for Agro-products, Ministry of Agriculture, Shanghai Academy of Agricultural Sciences, 1000 Jinqi Road, Shanghai 201403 (China); Liao, Yu-Cai, E-mail: ycliao06@yahoo.com.cn [Molecular Biotechnology Laboratory of Triticeae Crops, Huazhong Agricultural University, Wuhan 430070 (China); College of Plant Science and Technology, Huazhong Agricultural University, Wuhan 430070 (China); National Center of Plant Gene Research, Wuhan 430070 (China)

    2013-02-18

    Graphical abstract: A phage-displayed chicken scFv antibody, FvSG7, binds on the surface antigen of conidiospores and the mycelia of F. verticillioides. Its fusion with alkaline phosphatase (AP) through a 218 linker displayed a 4-fold higher affinity compared with the parent scFv antibody and efficiently detected toxigenic Fusarium pathogens in cereal grains. Highlights: ► Generation of a highly reactive scFv antibody against F. verticillioides. ► Localization of the antibody binding to the surface target of F. verticillioides. ► Expression of the antibody–alkaline phosphatase (AP) fusion linked by a 218 linker. ► The antibody–AP fusion has a higher affinity than the parental antibody. ► The antibody–AP fusion detects toxigenic Fusarium pathogens in cereal grains. -- Abstract: Fusarium and its poisonous mycotoxins are distributed worldwide and are of particular interest in agriculture and food safety. A simple analytical method to detect pathogens is essential for forecasting diseases and controlling mycotoxins. This article describes a proposed method for convenient and sensitive detection of Fusarium pathogens that uses the fusion of single-chain variable fragment (scFv) and alkaline phosphatase (AP). A highly reactive scFv antibody specific to soluble cell wall-bound proteins (SCWPs) of F. verticillioides was selected from an immunized chicken phagemid library by phage display. The antibody was verified to bind on the surface of ungerminated conidiospores and mycelia of F. verticillioides. The scFv–AP fusion was constructed, and soluble expression in bacteria was confirmed. Both the antibody properties and enzymatic activity were retained, and the antigen-binding capacity of the fusion was enhanced by the addition of a linker. Surface plasmon resonance measurements confirmed that the fusion displayed 4-fold higher affinity compared with the fusion's parental scFv antibody. Immunoblot analyses showed that the fusion had good binding

  11. A comparison of labelled antibody methods for the detection of virus antigens in cell monolayers

    International Nuclear Information System (INIS)

    Oram, J.D.; Crooks, A.J.

    1979-01-01

    A number of labelled antibody methods have been applied to the detection of Semliki Forest virus antigens after replication of the virus in monolayers of host cells in multi-well polystyrene plates. The importance of several reaction variables has been investigated and the sensitivity of the methods compared for different periods of virus replication. Direct assays with radio-labelled antibody (RLA) and indirect assays peroxidase-antiperoxidase complexes (PAP) were equally sensitive. Direct and indirect assays using enzyme-linked antibodies (ELA) were slightly less sensitive than the direct RLA and PAP methods but were more sensitive than the indirect RLA or fluorescent antibody (FLA) methods. Direct assays using ELA were more rapid and easier to perform than the other assay methods. (Auth.)

  12. Development of a simple and quick immunochromatography method for detection of anti-HPV-16/-18 antibodies

    Science.gov (United States)

    Endo, Fumiko; Tabata, Tsutomu; Sadato, Daichi; Kawamura, Machiko; Ando, Noriyuki; Ukaji, Masako; Kobayashi, Kaoru; Kobayashi, Yukuharu; Ikeda, Tomoaki; Shibasaki, Futoshi

    2017-01-01

    Immunochromatography (IC) is widely used to detect target molecules in biological fluids. Since this method can be performed without a special technique or device, IC is a convenient way to assess the existence of antibodies or pathogens such as viruses and bacteria, simply and quickly. In this study, we established an IC method to detect serum antibodies against oncogenic human papillomavirus (HPV)-16 and HPV-18 L1 proteins using recombinant L1 proteins produced by silkworms as antigens. Infection of oncogenic HPVs is a major risk factor of cervical cancer, which is one of the most common cancers in women worldwide. We first measured blood sera of two groups by magnetic beads enzyme-linked immunosorbent assay (MB-ELISA). For the first group, sera were collected prospectively from young women who planned to receive HPV vaccination. The second group consisted of children under 20 years of age, non-vaccinated healthy women, vaccinated healthy women, dysplasia, cervical intraepithelial neoplasia III, and cervical cancer patients. We confirmed that standard vaccination doses significantly increased serum HPV antibody concentrations, and the level was sustained at least more than 30 months after vaccination. In contrast, an increase in antibody concentration was not observed in patients with precancerous cervical changes and cervical cancer. We next measured the samples in both groups using the IC method we originally developed, and found that the measurement values of IC highly correlated with those of MB-ELISA. The simple and quick IC method would be a useful tool for rapid monitoring of L1 specific antibody levels in a non-laboratory environment. With less than one drop of serum, our IC can easily detect serum HPV-16/-18 antibodies within 15 minutes, without the need for electronic devices or techniques. PMID:28158224

  13. Development of a simple and quick immunochromatography method for detection of anti-HPV-16/-18 antibodies.

    Directory of Open Access Journals (Sweden)

    Fumiko Endo

    Full Text Available Immunochromatography (IC is widely used to detect target molecules in biological fluids. Since this method can be performed without a special technique or device, IC is a convenient way to assess the existence of antibodies or pathogens such as viruses and bacteria, simply and quickly. In this study, we established an IC method to detect serum antibodies against oncogenic human papillomavirus (HPV-16 and HPV-18 L1 proteins using recombinant L1 proteins produced by silkworms as antigens. Infection of oncogenic HPVs is a major risk factor of cervical cancer, which is one of the most common cancers in women worldwide. We first measured blood sera of two groups by magnetic beads enzyme-linked immunosorbent assay (MB-ELISA. For the first group, sera were collected prospectively from young women who planned to receive HPV vaccination. The second group consisted of children under 20 years of age, non-vaccinated healthy women, vaccinated healthy women, dysplasia, cervical intraepithelial neoplasia III, and cervical cancer patients. We confirmed that standard vaccination doses significantly increased serum HPV antibody concentrations, and the level was sustained at least more than 30 months after vaccination. In contrast, an increase in antibody concentration was not observed in patients with precancerous cervical changes and cervical cancer. We next measured the samples in both groups using the IC method we originally developed, and found that the measurement values of IC highly correlated with those of MB-ELISA. The simple and quick IC method would be a useful tool for rapid monitoring of L1 specific antibody levels in a non-laboratory environment. With less than one drop of serum, our IC can easily detect serum HPV-16/-18 antibodies within 15 minutes, without the need for electronic devices or techniques.

  14. Technetium-99m labeled monoclonal antibodies in the detection of metastatic melanoma

    International Nuclear Information System (INIS)

    Serafini, A.N.; Kotler, J.; Feun, L.; Dewanjee, M.; Robinson, D.; Salk, D.; Sfakianakis, G.; Abrams, P.; Savaraj, N.; Goodwin, D.

    1989-01-01

    Twenty-six stage II/III malignant melanoma patients with 321 measurable metastatic lesions were imaged using Fab fragments of an IgG murine monoclonal antibody labeled specifically with 10-30 mCi Tc-99m with a bi-functional chelating method (NeoRx, Seattle, WA). There were no side effects or adverse reactions. Immunoscintigraphy demonstrated 66.6% of lesions larger than 1 cm and 92.5% of lesions larger than 3 cm. Most frequently detected metastases were in lymph nodes, subcutaneous areas, and bone. Of lesions less than 1 cm, 23.6% were detected if superficial cutaneous lesions were excluded. The smallest detectable lesion was 4 mm. Twenty-one additional clinically unsuspected sites were visualized in 12 of the 26 patients studied. Of these, 56% were confirmed as metastasis by other tests. There were apparent nonspecific localizations owing to other causes, including fracture, varicosities, skin abscess and pneumonitis. Increased experience in image analysis facilitates correct interpretation of these localizations. This study demonstrates that imaging with Tc-99m labeled antibody fragments detects melanoma lesions in organs routinely surveyed and in other areas not routinely assessed by other imaging techniques. The procedure is readily performed and safe. The principal advantage of the test is its ability to survey the entire body and all organs with a single test. Its principal limitation, in common with other diagnostic imaging procedures, is its poor sensitivity for detecting lesions less than 1 cm

  15. Myostatin inhibitors in sports drug testing: Detection of myostatin-neutralizing antibodies in plasma/serum by affinity purification and Western blotting.

    Science.gov (United States)

    Walpurgis, Katja; Thomas, Andreas; Schänzer, Wilhelm; Thevis, Mario

    2016-02-01

    Myostatin is a key regulator of skeletal muscle growth and inhibition of its signaling pathway results in an increased muscle mass and function. The aim of this study was to develop a qualitative detection assay for myostatin-neutralizing antibodies for doping control purposes by using immunological approaches. To detect different types of myostatin-neutralizing antibodies irrespective of their amino acid sequence, an immunological assay specific for antibodies directed against myostatin and having a human Fc domain was established. Affinity purification and Western blotting strategies were combined to allow extracting and identifying relevant analytes from 200 μL of plasma/serum in a non-targeted approach. The assay was characterized regarding specificity, linearity, precision, robustness, and recovery. The assay was found to be highly specific, robust, and linear from 0.1 to 1 μg/mL. The precision was successfully specified at three different concentrations and the recovery of the affinity purification was 58%. Within this study, an immunological detection assay for myostatin-neutralizing antibodies present in plasma/serum specimens was developed and successfully characterized. The presented approach can easily be modified to include other therapeutic antibodies and serves as proof-of-concept for the detection of antibody-based myostatin inhibitors in doping control samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Bluetongue virus: comparative evaluation of enzyme-linked immunosorbent assay, immunodiffusion, and serum neutralization for detection of viral antibodies.

    OpenAIRE

    Poli, G; Stott, J; Liu, Y S; Manning, J S

    1982-01-01

    Comparative studies on the detection of bovine serum immunoglobulin G antibodies to bluetongue virus with an enzyme-linked immunosorbent assay, an immunodiffusion method, and a serum neutralization assay demonstrated complete concordance between the enzyme-linked immunosorbent assay and the serum neutralization assay results. However, the immunodiffusion method failed to detect bluetongue virus antibody in a substantial number of sera found to possess bluetongue virus immunoglobulin G with th...

  17. Scintigraphic detection of metastatic melanoma using indium 111/DTPA conjugated anti-gp240 antibody (ZME-018)

    International Nuclear Information System (INIS)

    Kirkwood, J.M.; Neumann, R.D.; Zoghbi, S.S.; Ernstoff, M.S.; Cornelius, E.A.; Shaw, C.; Ziyadeh, T.; Fine, J.A.; Unger, M.W.

    1987-01-01

    We evaluated the toxicity, pharmacokinetics, and localization of a monoclonal IgG2 alpha murine anti-human melanoma (gp240) antibody (ZME-018) that recognizes a tumor-associated cell surface glycoprotein of 240,000 molecular weight present in most melanomas. The antibody was conjugated with DTPA (diethylenetriamine pentaacetic acid) and labeled by chelation of 111 In. One mg of antibody labeled with 5 mCi of 111 In was infused, together with 0 to 40 mg of cold carrier ZME-018. The blood clearance, urinary excretion, and in vivo localization were determined in 26 patients. Scintigraphic images were obtained at 24 hours and 72 hours in all patients. Mild toxicity occurred in one patient. The half-time clearance of labeled monoclonal murine antibody (MoAb) from the blood increased from 16.1 hours at an antibody dose of 1 mg to 35.9 hours at 40 mg. Males showed faster clearance from the blood than did females or a single castrated male, perhaps due to selective concentration of antibody in the testes. Nonspecific uptake in liver, spleen, bone marrow, and intestine was seen in all patients. The percentage of known metastatic foci detected increased with the total dosage of antibody, from 23% at doses less than or equal to 5 mg, to 65%, 87% and 78% for 10, 20, and 40 mg, respectively. We conclude that at doses of greater than or equal to 10 mg, ZME-018 is a safe and potentially useful agent for the scintigraphic detection of metastatic malignant melanoma

  18. Detection and quantification of microcystins (cyanobacterial hepatotoxins) with recombinant antibody fragments isolated from a naïve human phage display library.

    Science.gov (United States)

    McElhiney, J; Lawton, L A; Porter, A J

    2000-12-01

    Single-chain antibody fragments against the cyanobacterial hepatotoxin microcystin-LR were isolated from a naive human phage display library and expressed in Escherichia coli. In competition enzyme-linked immunosorbent assay (ELISA), the most sensitive antibody clone selected from the library detected free microcystin-LR with an IC(50) value of 4 microM. It was found to cross react with three other microcystin variants - microcystin-RR, microcystin-LW and microcystin-LF - and detected microcystins in extracts of the cyanobacterium Microcystis aeruginosa, found to contain the toxins by high-performance liquid chromatography (HPLC). The quantification of microcystins in these extracts by ELISA and HPLC showed good correlation. Although the antibody isolated in this study was considerably less sensitive than the polyclonal and monoclonal antibodies already available for microcystin detection, phage display technology represents a cheaper, more rapid alternative for the production of anti-microcystin antibodies than the methods currently in use.

  19. Capillary zone electrophoresis-tandem mass spectrometry detects low concentration host cell impurities in monoclonal antibodies

    Science.gov (United States)

    Zhu, Guijie; Sun, Liangliang; Heidbrink-Thompson, Jennifer; Kuntumalla, Srilatha; Lin, Hung-yu; Larkin, Christopher J.; McGivney, James B.; Dovichi, Norman J.

    2016-01-01

    We have evaluated capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) for detection of trace amounts of host cell protein impurities in recombinant therapeutics. Compared to previously published procedures, we have optimized the buffer pH used in the formation of a pH junction to increase injection volume. We also prepared a five-point calibration curve by spiking twelve standard proteins into a solution of a human monoclonal antibody. A custom CZE-MS/MS system was used to analyze the tryptic digest of this mixture without depletion of the antibody. CZE generated a ~70 min separation window (~90 min total analysis duration) and ~300 peak capacity. We also analyzed the sample using ultra-performance liquid chromatography (UPLC)-MS/MS. CZE-MS/MS generated ~five times higher base peak intensity and more peptide identifications for low-level spiked proteins. Both methods detected all proteins spiked at the ~100 ppm level with respect to the antibody. PMID:26530276

  20. Development of monoclonal antibody-based sandwich ELISA for detection of dextran.

    Science.gov (United States)

    Wang, Sheng-Yu; Li, Zhe; Wang, Xian-Jiang; Lv, Sha; Yang, Yun; Zeng, Lian-Qiang; Luo, Fang-Hong; Yan, Jiang-Hua; Liang, Da-Feng

    2014-10-01

    Dextran as anti-nutritional factor is usually a result of bacteria activity and has associated serial problems during the process stream in the sugar industry and in medical therapy. A sensitive method is expected to detect dextran quantitatively. Here we generated four monoclonal antibodies (MAbs) against dextran using dextran T40 conjugated with bovine serum albumin (BSA) as immunogen in our lab following hybridoma protocol. Through pairwise, an MAb named D24 was determined to be conjugated with horseradish peroxidase (HRP) and was used in the establishment of a sensitive sandwich enzyme-linked immunosorbent assay (ELISA) method for determination of dextran, in which MAb D9 was chosen as a capture antibody. The detection limit and working scope of the developed sandwich ELISA method were 3.9 ng/mL and 7.8-500 ng/mL with a correlation coefficient of 0.9909. In addition, the cross-reaction assay demonstrated that the method possessed high specificity with no significant cross-reaction with dextran-related substances, and the recovery rate ranged from 96.35 to 102.00%, with coefficient of variation ranging from 1.58 to 6.94%. These results indicated that we developed a detection system of MAb-based sandwich ELISA to measure dextran and this system should be a potential tool to determine dextran levels.

  1. Validation of an improved anaplasma antibody cELISA kit for detection of anaplasma ovis antibody in domestic sheep at the U.S. Sheep Experiment Station in Dubois, ID

    Science.gov (United States)

    An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identifie...

  2. A Generic Method for Fungal Spore Detection: The use of a monoclonal antibody and surface plasmon resonance

    DEFF Research Database (Denmark)

    Skottrup, Peter; Hearty, Stephen; Frøkiær, Hanne

    causing wheat yellow rust. We have developed mabs towards intact whole spores and used a subtractive inhibition format for detection of spores in solution. The antibody was incubated with different spore concentrations and the remaining free antibody was quantified using a BIAcore® 3000 sensor. Decreasing...

  3. Human anti-HIV IgM detection by the OraQuick ADVANCE® Rapid HIV 1/2 Antibody Test.

    Science.gov (United States)

    Guillon, Geraldine; Yearwood, Graham; Snipes, Casey; Boschi, Daniel; Reed, Michael R

    2018-01-01

    The Centers for Disease Control and Prevention (CDC) and many public health jurisdictions continue to advocate for the most sensitive rapid HIV test that is available. Currently, the recommendation is to utilize tests that can detect HIV infection biomarkers within 30 days of infection, when initial immune responses are mounted. The infected patient's IgM response is often used to detect acute infection within a 20-25 days window after infection. This requirement applies to lab-based testing with automated analyzers and rapid, point of care (POC) testing used for screening in a non-clinical setting. A recent study has demonstrated that POC tests using a Protein A-based detection system can detect samples with predominantly HIV-1 IgM reactivity (Moshgabadi et al., 2015). The OraQuick ADVANCE ® Rapid HIV-1/2 Antibody Test (OraQuick ADVANCE ®) also uses Protein A as the detection protein in the antibody-binding colloidal gold conjugate, so it is expected that the OraQuick ADVANCE ® Test will also detect samples with predominantly IgM reactivity. This report definitively demonstrates that the OraQuick ADVANCE ® Test can detect IgM antibodies during an acute infection window period of approximately 20-25 days after infection, and is therefore suitable for use in testing environments requiring adherence to current CDC recommendations.

  4. Immunofluorescent detection in the ovary of host antibodies against a secretory ferritin injected into female Haemaphysalis longicornis ticks.

    Science.gov (United States)

    Galay, Remil Linggatong; Matsuo, Tomohide; Hernandez, Emmanuel Pacia; Talactac, Melbourne Rio; Kusakisako, Kodai; Umemiya-Shirafuji, Rika; Mochizuki, Masami; Fujisaki, Kozo; Tanaka, Tetsuya

    2018-04-01

    Due to the continuous threat of ticks and tick-borne diseases to human and animal health worldwide, and the drawbacks of chemical acaricide application, many researchers are exploring vaccination as an alternative tick control method. Earlier studies have shown that host antibodies can circulate in the ticks, but it has not been confirmed whether these antibodies can be passed on to the eggs. We previously reported that ticks infesting rabbits immunized with a recombinant secretory ferritin of Haemaphysalis longicornis (HlFER2) had reduced egg production and hatching. Here we attempted to detect the presence of antibodies against HlFER2 in the ovary and eggs of female ticks through immunofluorescent visualization. Purified anti-HlFER2 antibodies or rabbit IgG for control was directly injected to engorged female H. longicornis. Ovaries and eggs after oviposition were collected and prepared for an indirect immunofluorescent antibody test. Positive fluorescence was detected in ovaries one day post-injection of anti-HlFER2 antibodies. Through silencing of Hlfer2 gene, we also determined whether the injected antibodies can specifically bind to native HlFER2. Immunofluorescence was observed in the oocytes of dsLuciferase control ticks injected with anti-HlFER2 antibodies, but not in the oocytes of Hlfer2-silenced ticks also injected with anti-HlFER2 antibodies. Our current findings suggest that host antibodies can be passed on to the oocytes, which is significant in formulating a vaccine that can disrupt tick reproduction. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Serologic detection of coccidioidomycosis antibodies in northeast Brazil.

    Science.gov (United States)

    Cordeiro, Rossana de Aguiar; Fechine, Maria Auxiliadora Bezerra; Brilhante, Raimunda Sâmia Nogueira; Rocha, Marcos Fábio Gadelha; da Costa, Ana Karoline Freire; Nagao, Maria Aparecida Tiemi Dias; de Camargo, Zoilo Pires; Sidrim, José Júlio Costa

    2009-04-01

    Coccidioidomycosis is a systemic infection caused by Coccidioides spp. The disease is endemic in Brazil but its incidence is underreported as it is not a notifiable disease. This article presents the results of a serologic survey carried out with 229 volunteers in northeast Brazil by the immunodiffusion (ID) test with commercial Coccidioides spp. antigens. The commercial ID test detected 15 individuals without clinical diagnosis of the disease and two individuals in treatment for coccidioidomycosis. Regarding the epidemiological data, most of the positive individuals were male, between 18 and 65 years of age and were engaged in armadillo hunting. Three women who had never participated in armadillo hunts also displayed positive results for coccidioidal antibodies. Besides armadillo hunts, exposure to environmental dust in endemic areas may account for the serologic response detected in the study. The data from this study suggest the importance of performing epidemiological surveys for coccidioidomycosis in order to understand the prevalence of this disease in Brazil.

  6. Development and characterization of highly informative ELISA for the detection of IgG and IgA antibodies to Сhlamydia trachomatis

    Directory of Open Access Journals (Sweden)

    O. Yu. Galkin

    2018-04-01

    Full Text Available The goal of this work was developing of highly informative an enzyme-linked immunosorbent assay (ELISA for the detection of IgG and IgA antibodies against to Chlamydia trachomatis, as well as comparative characterization of developed assay using standardized control materials. The study was conducted using: monoclonal antibodies (McAbs to human IgA and IgG; recombinant Ch. trachomatis proteins – Pgp3, major outer membrane protein (MOMP; two panels of characterized sera and four reference ELISA kits. The study of immunochemical activity of peroxidase conjugates of McAbs was performed in comparison with conjugates of commercial analogues: anti-IgG McAb 2A11 and anti-IgA McAb AD3. About half of the conjugates from the received McAbs panel were more active compared to the reference antibody conjugates. It was quite justified to use the conjugates of antibodies that interact with different antigenic determinants. When IgG antibodies were detected to MOMP, it was justified 1.14-1.56 times more; when IgA antibodies were detected to MOMP, it was justified 1.16-1.37 times more. ELISA for detecting IgG/IgA antibodies to MOMP and Pgp3 of Ch. trachomatis were evaluated using appropriately described serum panels OCO-42-28-313-00 and OCO-42-28-314-00. Comparative studies of the developed ELISA for the detection of IgG and IgA antibodies to the MOMP and Pgp3 of Ch. trachomatis showed their prominent advantage over the commercial analogues, which more clearly demonstrates the difference in the ratio of average values of optical density of positive and negative samples of the described panel of sera: this indicator for commercial kits was 1.36-3.59 times less.

  7. Anti-double strand (ds) DNA antibody formation by NZB/W (F1) spleen cells in a microculture system detected by solid phase radioimmunoassay.

    Science.gov (United States)

    Okudaira, H; Terada, E; Ogita, T; Aotsuka, S; Yokohari, R

    1981-01-01

    A solid-phase radioimmunoassay method was devised to detect mouse anti-double strand (ds) DNA antibody. This method could easily detect the anti-dsDNA antibody in 1 : 10,000 dilutions (1 unit) of pooled 9-10-month-old female NZB/W F1 sera. The sensitivity was about 10(3)- and 10(2)-fold higher than that of the modified Farr method and of the double antibody technique respectively. NZB/W mice developed high titer anti-dsDNA antibody as they grew older. Spleen cells brought to a microculture system using flat-bottomed polystyrene plates produced anti-dsDNA antibody clearly detectable by solid-phase radioimmunoassay. Anti-dsDNA antibody produced in vitro (y units) was in close correlation with the anti-dsDNA antibody titer of the spleen donor (x units) (y = 4.8 X 10(-2) x -65, gamma = 0.94, P less than 0.001). A combination of the microculture system and solid-phase radioimmunoassay was recommended for the characterization of anti-dsDNA antibody-forming cells.

  8. Anti-double strand (ds) DNA antibody formation by NZB/W (F1) spleen cells in a microculture system detected by solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Okudaira, H.; Terada, E.; Ogita, T.; Aotsuka, S.; Yokohari, R.

    1981-01-01

    A solid-phase radioimmunoassay method was devised to detect mouse anti-double strand (ds) DNA antibody. This method could easily detect the anti-ds DNA antibody in 1 : 10,000 dilutions (1 unit) of pooled 9-10 month-old female NZB/W F1 sera. The sensitivity was about 10 3 and 10 2 -fold higher than that of the modified Farr method and of the double antibody technique respectively. NZB/W mice developed high titer anti-dsDNA antibody as they grew older. Spleen cells brought to a microculture system using flat-bottomed polystyrene plates produced anti-dsDNA antibody clearly detectable by solid-phase radioimmunoassay. Anti-dsDNA antibody produced in vitro (y units) was in close correlation with the anti-dsDNA antibody titer of the spleen donor (x units) (y = 4.8 X 10 -2 x-65, γ = 0.94, P < 0.001). A combination of the microculture system and solid-phase radioimmunoassay was recommended for the characterization of anti-dsDNA antibody-forming cells. (Auth.)

  9. Direct immobilization of antibodies on Zn-doped Fe{sub 3}O{sub 4} nanoclusters for detection of pathogenic bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Monalisa; Lee, Sanghee; Kwon, Donghoon; Hwang, Jeongin; Lee, Hyeonjeong; Hwang, Seokyung; Jeon, Sangmin, E-mail: jeons@postech.ac.kr

    2017-02-01

    Zinc-doped magnetic nanoclusters (Zn-MNCs) were synthesized and used to detect pathogenic bacteria in milk. Hydrothermally synthesized Zn-MNCs exhibited stronger magnetic properties than pure MNCs, which facilitated the magnetic separation from the sample using a permanent magnet. The presence of accessible Zn sites allows the direct immobilization of half-fragmented antibodies over Zn-MNCs through strong Zn−S bonds and prevents the tedious multiple steps of molecular functionalization or coating with costly noble metals prior to conjugation with an antibody. After the capture and magnetic separation of Salmonella in milk using the antibody-functionalized Zn-MNCs, the concentration of bacteria was determined with a portable ATP luminometer and the detection limit was found to be 10 CFU/mL. - Highlights: • Zn-doped Fe{sub 3}O{sub 4} nanoclusters (Zn-MNCs) were synthesized by hydrothermal method. • Antibodies were directly immobilized over Zn-MNCs through strong Zn–S{sub thiol} bonds. • Higher magnetization of Zn-MNCs than pure MNCs facilitates the magnetic separation. • Detection limit of pathogenic bacteria in milk was found to be 10 cfu/mL. • Cost effective, sensitive and selective detection of bacteria.

  10. Development of an Enzyme Linked Immunosorbent Assay to Detect Chicken Parvovirus Specific Antibodies

    Science.gov (United States)

    Here we report the development and application of an enzyme linked immunosorbent assay to detect parvovirus-specific antibodies in chicken sera. We used an approach previously described for other parvoviruses to clone and express viral structural proteins in insect cells from recombinant baculovirus...

  11. A solid phase radio immunoassay on hydrophobic membrane filters: detection of antibodies to gonocal surface antigens

    International Nuclear Information System (INIS)

    Lambden, P.R.; Watt, P.J.

    1978-01-01

    A solid phase radioimmunoassay (SPRIA) has been developed for detection of IgG antibodies to gonococcal outer membrane components. Gonococcal antigens was immobilised on a solid support by covalent coupling to CNBr-activated Sepharose in the presence of the detergent Triton X-100. Binding of specific antibody to the Sepharose-antigen complex was detected using radiolabelled Protein A as the antiglobulin. Protein A was labelled by radioacetylation with tritiated acetic anhydride, yielding a product of high specific activity and high stability. No detectable loss of activity was observed over a ten month period. The entire assay was performed on Mitex teflon hydrophobic membrane filters which held the Sepharose beads and aqueous supernatant as a discrete drop of liquid. The supernatants and incubation were easily and rapidly removed from the beads by suction on a specially-designed manifold system. This procedure removed the need for repeated and time-consuming centrifugations. Titres were obtained graphically from double log plots of cpm bound versus antiserum dilution by extrapolation of the straight line to a point corresponding to twice the control level of radioactivity binding. The assay proved to be a very reliable and simple procedure for the detection of IgG antibodies to gonococcal surface antigens. (Auth.)

  12. Detection of IgM and IgG antibodies to Chlamydophila pneumoniae in pediatric community-acquired lower respiratory tract infections

    Directory of Open Access Journals (Sweden)

    Surinder Kumar

    2011-01-01

    Full Text Available Context: Chlamydophila pneumoniae (C. pneumoniae is an emerging infectious agent with a spectrum of clinical manifestations including lower and upper respiratory tract infections. Aims: To investigate the role of C. pneumoniae in community-acquired lower respiratory tract infections (LRTIs in children using serological tests. Settings and Design: Two hundred children, age 2 months to 12 years, hospitalized for community-acquired LRTIs were investigated for C. pneumoniae etiology. Materials and Methods: We investigated 200 children hospitalized for community-acquired LRTIs, using ELISA for detecting anti-C. pneumoniae IgM and IgG antibodies. The demographic, clinical and radiological findings for C. pneumoniae antibody positive and C. pneumoniae antibody negative cases were compared. Statistical Analysis Used: Data analysis was performed by Chi-square test and Fisher′s exact tests using Epi Info (2002. Results: Clinical and radiological findings in both the groups were comparable. Serological evidence of C. pneumoniae infection was observed in 12 (6% patients; specific IgM antibodies were detected in 11 (91.67%; specific IgG antibodies in 1 (8.33% patients, while 4-fold rise in C. pneumoniae IgG antibody titers were noted in none of the patients. Conclusions: C. pneumoniae has a role in community-acquired LRTIs, even in children aged < 5 years. Serological detection using ELISA would enable pediatricians in better management of C. pneumoniae infections.

  13. Detection of HLA Antibodies in Organ Transplant Recipients – Triumphs and Challenges of the Solid Phase Bead Assay

    Science.gov (United States)

    Tait, Brian D.

    2016-01-01

    This review outlines the development of human leukocyte antigen (HLA) antibody detection assays and their use in organ transplantation in both antibody screening and crossmatching. The development of sensitive solid phase assays such as the enzyme-linked immunosorbent assay technique, and in particular the bead-based technology has revolutionized this field over the last 10–15 years. This revolution however has created a new paradigm in clinical decision making with respect to the detection of low level pretransplant HLA sensitization and its clinical relevance. The relative sensitivities of the assays used are discussed and the relevance of conflicting inter-assay results. Each assay has its advantages and disadvantages and these are discussed. Over the last decade, the bead-based assay utilizing the Luminex® fluorocytometer instrument has become established as the “gold standard” for HLA antibody testing. However, there are still unresolved issues surrounding this technique, such as the presence of denatured HLA molecules on the beads which reveal cryptic epitopes and the issue of appropriate fluorescence cut off values for positivity. The assay has been modified to detect complement binding (CB) in addition to non-complement binding (NCB) HLA antibodies although the clinical relevance of the CB and NCB IgG isotypes is not fully resolved. The increase sensitivity of the Luminex® bead assay over the complement-dependent cytotoxicity crossmatch has permitted the concept of the “virtual crossmatch” whereby the crossmatch is predicted to a high degree of accuracy based on the HLA antibody specificities detected by the solid phase assay. Dialog between clinicians and laboratory staff on an individual patient basis is essential for correct clinical decision making based on HLA antibody results obtained by the various techniques. PMID:28018342

  14. Development of a multiplex Luminex assay for detecting swine antibodies to structural and nonstructural proteins of foot-and-mouth disease virus in Taiwan.

    Science.gov (United States)

    Chen, Tsu-Han; Lee, Fan; Lin, Yeou-Liang; Pan, Chu-Hsiang; Shih, Chia-Ni; Tseng, Chun-Hsien; Tsai, Hsiang-Jung

    2016-04-01

    Foot-and-mouth disease (FMD) and swine vesicular disease (SVD) are serious vesicular diseases that have devastated swine populations throughout the world. The aim of this study was to develop a multianalyte profiling (xMAP) Luminex assay for the differential detection of antibodies to the FMD virus of structural proteins (SP) and nonstructural proteins (NSP). After the xMAP was optimized, it detected antibodies to SP-VP1 and NSP-3ABC of the FMD virus in a single serum sample. These tests were also compared with 3ABC polypeptide blocking enzyme-linked immunosorbent assay (ELISA) and virus neutralization test (VNT) methods for the differential diagnosis and assessment of immune status, respectively. To detect SP antibodies in 661 sera from infected naïve pigs and vaccinated pigs, the diagnostic sensitivity (DSn) and diagnostic specificity (DSp) of the xMAP were 90.0-98.7% and 93.0-96.5%, respectively. To detect NSP antibodies, the DSn was 90% and the DSp ranged from 93.3% to 99.1%. The xMAP can detect the immune response to SP and NSP as early as 4 days postinfection and 8 days postinfection, respectively. Furthermore, the SP and NSP antibodies in all 15 vaccinated but unprotected pigs were detected by xMAP. A comparison of SP and NSP antibodies detected in the sera of the infected samples indicated that the results from the xMAP had a high positive correlation with results from the VNT and a 3ABC polypeptide blocking ELISA assay. However, simultaneous quantitation detected that xMAP had no relationship with the VNT. Furthermore, the specificity was 93.3-94.9% with 3ABC polypeptide blocking ELISA for the FMDV-NSP antibody. The results indicated that xMAP has the potential to detect antibodies to FMDV-SP-VP1 and NSP-3ABC and to distinguish FMDV-infected pigs from pigs infected with the swine vesicular disease virus. Copyright © 2014. Published by Elsevier B.V.

  15. Antibody Detection, Isolation, Genotyping, and Virulence of Toxoplasma gondii in Captive Felids from China

    Directory of Open Access Journals (Sweden)

    Yu-Rong Yang

    2017-07-01

    Full Text Available The felids are the only definitive hosts of Toxoplasma gondii, which could excrete oocysts into the environment and provide an infection source for toxoplasmosis in various warm-blooded animal species, particularly the captive felids that live close to human communities. The infection rate of the captive felids is a perfect standard in detecting the presence of Toxoplasma gondii oocysts in the environment. In this study, sera or tissue samples from zoo (1 young tiger, 2 adult tigers, 6 young lions, farm (10 masked palm civets, and pet hospital (28 cats from Henan Province (China were collected. The sera (n = 47 were tested for immunoglobulin G (IgG antibodies against T. gondii by using modified agglutination test (MAT, whereas the hearts tissue (n = 40 were bioassayed in mice to isolate T. gondii strains. The genotype was distinguished by using PCR-RFLP of 10 loci (SAG1, SAG2, SAG3, GRA6, BTUB, L358, c22-8, PK1, c29-2, and Apico. The detection rate for the T. gondii antibody in captive felids was 21.3% (10/47. One viable T. gondii strain (TgCatCHn4 was obtained from a cat heart tissue, and its genotype was ToxoDB#9. The oocysts of ToxoDB#9 were collected from a T. gondii-free cat. The virulence of TgCatCHn4 was low and no cysts were detected in the brain of mice at 60 days post-inoculation. The finding of the present study suggested a widespread exposure of T. gondii for felids in Henan Province of central China, particularly those from the zoological gardens and homes. ToxoDB#9 was the predominant strain in China. Preventive measures against T. gondii oocyst contamination of various components of the environment should thus be implemented, including providing pre-frozen meat, well-cooked cat food, cleaned fruits and vegetables, monitoring birds and rodents, inactive T. gondii oocysts in felids feces, and proper hygiene.

  16. Electronic Cortisol Detection Using an Antibody-Embedded Polymer Coupled to a Field-Effect Transistor.

    Science.gov (United States)

    Jang, Hyun-June; Lee, Taein; Song, Jian; Russell, Luisa; Li, Hui; Dailey, Jennifer; Searson, Peter C; Katz, Howard E

    2018-05-16

    A field-effect transistor-based cortisol sensor was demonstrated in physiological conditions. An antibody-embedded polymer on the remote gate was proposed to overcome the Debye length issue (λ D ). The sensing membrane was made by linking poly(styrene- co-methacrylic acid) (PSMA) with anticortisol before coating the modified polymer on the remote gate. The embedded receptor in the polymer showed sensitivity from 10 fg/mL to 10 ng/mL for cortisol and a limit of detection (LOD) of 1 pg/mL in 1× PBS where λ D is 0.2 nm. A LOD of 1 ng/mL was shown in lightly buffered artificial sweat. Finally, a sandwich ELISA confirmed the antibody binding activity of antibody-embedded PSMA.

  17. Detection of koi herpesvirus (KHV) using a monoclonal antibody against Cyprinus carpio IgM.

    Science.gov (United States)

    Li, Yingying; Zheng, Shucheng; Wang, Qing; Bergmann, Sven M; Zeng, Weiwei; Wang, Yingying; Liu, Chun; Shi, Cunbin

    2017-08-01

    Koi herpesvirus disease (KHVD) is associated with high mortality in both common carp and koi carp (Cyprinus carpio L.) worldwide. The indirect detection of fish viruses based on the identification of antibodies has emerged as a practical and reliable means of diagnosis. Thus, it is important to create monoclonal antibodies (MAbs) against carp IgM. By using hybridoma-monoclonal antibody technology, one hybridoma cell line secreting MAbs against IgM from carp was established. In western blot analysis, the secreted MAb from cell line A5-E10 recognized the heavy chain of IgM from common carp or koi but did not react with immunoglobulins from three different fish species: grass carp (Ctenopharyngodon idella), tilapia (Oreochromis mossambicus) and Mandarin fish (Siniperca chuatsi). These results demonstrated that this MAb is highly specific for the IgM of carp and suggested that it can be used for monitoring the immunity level of carp, for example for indirect KHV diagnosis by antibody ELISA. We therefore established an indirect ELISA, which was tested using 200 serum samples from koi from three farms. The final results showed that 147 (73.5%) samples were confirmed to be KHV antibody negative and 53 (26.5%) were definitely positive, containing antibodies against KHV.

  18. Preparation of anti-ciguatoxin monoclonal antibodies using synthetic haptens: sandwich ELISA detection of ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2014-01-01

    Ciguatera fish poisoning (CFP) is a form of food poisoning caused by the consumption of fish that have accumulated a type of sodium channel activator toxin called ciguatoxins (CTXs), which are produced by dinoflagellates of the genus Gambierdiscus through the food chain. CFP affects more than 50000 people each year. The extremely low level of CTXs in tainted fish has hampered the development of antibodies for the detection of these toxins. Monoclonal antibodies (mAbs) specific against major congeners of CTX3C, 51-hydroxyCTX3C, CTX1B, and 54-deoxyCTX1B were prepared by immunization of mice with protein conjugates of rationally designed synthetic haptens in place of the natural toxins. We found that haptenic groups possessing a surface area larger than 400 angstroms2 were required to produce mAbs that can bind strongly to CTXs. Direct sandwich ELISA utilizing two different monoclonal antibodies that bind specifically to one of the two wings of a CTX were established to detect CTXs. No cross-reactivity was observed against the other marine toxins tested, including brevetoxin A, brevetoxin B, okadaic acid, and maitotoxin.

  19. Monoclonal antibody-based serological methods for detection of Cucumber green mottle mosaic virus

    Directory of Open Access Journals (Sweden)

    Qian Yajuan

    2011-05-01

    Full Text Available Abstract Background Cucumber green mottle mosaic virus (CGMMV, a member of the genus Tobamovirus, can be transmitted by seeds and infects many cucurbit species, causing serious yield losses in cucumber and watermelon plants. In this paper, five serological methods including antigen-coated plate enzyme-linked immunosorbent assay (ACP-ELISA, triple antibody sandwich enzyme-linked immunosorbent assay (TAS-ELISA, Dot-immunobinding assay (DBIA, direct tissue blot immunoassay (DTBIA and immunocapture reverse transcriptase polymerase chain reaction (IC-RT-PCR were described for detection and diagnosis of CGMMV. Results Using the purified CGMMV particles as immunogens, six murine monoclonal antibodies (MAbs were produced. Five serological methods were established using the MAb 4H1 and detection sensitivity was compared using purified preparations and infected-plant tissue extracts. The detection sensitivity of ACP-ELISA was 0.16 ng of purified CGMMV, whereas TAS-ELISA was more sensitive than ACP-ELISA with a minimum detection of 0.04 ng of purified CGMMV. The sensitivities of TAS-ELISA and DBIA were similar for detecting CGMMV in infected-plant tissue extracts, and were four times higher than ACP-ELISA. The IC-RT-PCR was the most sensitive method, which could detect as little as 0.1 pg of purified virus. The detection sensitivity of IC-RT-PCR for CGMMV-infected plant tissues was about 400 times higher than that of TAS-ELISA and DBIA. Conclusions The established ACP-ELISA, TAS-ELISA, DBIA and DTBIA are suitable for routine CGMMV detection of large-scale samples in the field survey, while IC-RT-PCR is more sensitive and suitable for acquiring information about the viral genome.

  20. A study using an isotope probe comparing immunoassay with serology in detection of Brucella Abortus antibody

    International Nuclear Information System (INIS)

    Devlin, J.G.; Redington, F.; Stephenson, M.

    1986-01-01

    We report a comparison of radio-immunoassay with conventional serology in the detection of brucella abortus antibody from three laboratories. Overall agreement by Chi squared analysis is 5%. There are significant differences between laboratories and a significant number of sero negative suspect sera (from 20% - 60%) were positive by ratio-immunoassay test. We suspect that conventional serology under-reports the incidence of antibody to brucella abortus. (author)

  1. [Use of polymeric suspensions as a viral sorbent to detect cattle serum antibodies].

    Science.gov (United States)

    Stanishevskiĭ, Ia M; Lobova, T P; Gritskova, I A; Belousova, R V; Prokopov, N I; Tret'iakova, I V; Tkalia, E E

    2006-01-01

    The paper shows it possible to use stained polymeric microspheres, 1.7 microm in diameter, that contain viruses onto the surface, in the latex agglutination test to detect antibodies to the bovine serum viruses of infective rhinotracheitis, parainfluenza-3, viral diarrhea, respiratory syncytial infection, and adenoviral infection.

  2. Specific antibodies to porcine zona pellucida detected by quantitative radioimmunoassay in both fertile and infertile women

    International Nuclear Information System (INIS)

    Kurachi, H.; Wakimoto, H.; Sakumoto, T.; Aono, T.; Kurachi, K.

    1984-01-01

    The specific radioimmunoassay system was developed for the titration of the antibodies to porcine zona pellucida (ZP) in human sera by using 125 I-labeled purified porcine ZP as antigen, which is known to have cross-reactivity with human ZP. The antibodies in human sera were detected in 3 of 11 (27%) women with unexplained infertility, in 16 of 48 (33%) amenorrheic patients, in 4 of 12 (33%) fertile women, and in 3 of 10 (30%) men. Moreover, antibody titers in infertile women were no higher than those in fertile women and in men. These results seem to suggest that the antibodies in human sera that cross-react with porcine ZP may not be an important factor in causing infertility in women

  3. A novel polymorphism of human complement component C3 detected by means of a monoclonal antibody

    DEFF Research Database (Denmark)

    Koch, C; Behrendt, N

    1986-01-01

    A mouse monoclonal antibody, HAV 4-1, obtained after immunization of a BALB/c mouse with purified C3F, detected a novel genetic polymorphism of human complement component C3 in a simple immunoblotting system. The frequency of HAV 4-1-positive genes was 20.1%. Reactivity of HAV 4-1 was closely...... related to C3F, but certain individuals with the C3F allele did not react with HAV 4-1. Conversely, certain C3S homozygous individuals did react with HAV 4-1. The polymorphism detected by this monoclonal antibody is therefore different from the previously described polymorphism based on charge differences....

  4. Detection of anti-Giardia lamblia serum antibody among children of day care centers

    Directory of Open Access Journals (Sweden)

    Guimarães Semíramis

    2002-01-01

    Full Text Available OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF and enzyme-linked immunosorbent assay (ELISA for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3% showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3% and 100 (68% samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39% than IIF (70%. IIF also showed a higher concordance with microscopic examination than ELISA.

  5. Metabolomics reveals distinct, antibody-independent, molecular signatures of MS, AQP4-antibody and MOG-antibody disease.

    Science.gov (United States)

    Jurynczyk, Maciej; Probert, Fay; Yeo, Tianrong; Tackley, George; Claridge, Tim D W; Cavey, Ana; Woodhall, Mark R; Arora, Siddharth; Winkler, Torsten; Schiffer, Eric; Vincent, Angela; DeLuca, Gabriele; Sibson, Nicola R; Isabel Leite, M; Waters, Patrick; Anthony, Daniel C; Palace, Jacqueline

    2017-12-06

    The overlapping clinical features of relapsing remitting multiple sclerosis (RRMS), aquaporin-4 (AQP4)-antibody (Ab) neuromyelitis optica spectrum disorder (NMOSD), and myelin oligodendrocyte glycoprotein (MOG)-Ab disease mean that detection of disease specific serum antibodies is the gold standard in diagnostics. However, antibody levels are not prognostic and may become undetectable after treatment or during remission. Therefore, there is still a need to discover antibody-independent biomarkers. We sought to discover whether plasma metabolic profiling could provide biomarkers of these three diseases and explore if the metabolic differences are independent of antibody titre. Plasma samples from 108 patients (34 RRMS, 54 AQP4-Ab NMOSD, and 20 MOG-Ab disease) were analysed by nuclear magnetic resonance spectroscopy followed by lipoprotein profiling. Orthogonal partial-least squares discriminatory analysis (OPLS-DA) was used to identify significant differences in the plasma metabolite concentrations and produce models (mathematical algorithms) capable of identifying these diseases. In all instances, the models were highly discriminatory, with a distinct metabolite pattern identified for each disease. In addition, OPLS-DA identified AQP4-Ab NMOSD patient samples with low/undetectable antibody levels with an accuracy of 92%. The AQP4-Ab NMOSD metabolic profile was characterised by decreased levels of scyllo-inositol and small high density lipoprotein particles along with an increase in large low density lipoprotein particles relative to both RRMS and MOG-Ab disease. RRMS plasma exhibited increased histidine and glucose, along with decreased lactate, alanine, and large high density lipoproteins while MOG-Ab disease plasma was defined by increases in formate and leucine coupled with decreased myo-inositol. Despite overlap in clinical measures in these three diseases, the distinct plasma metabolic patterns support their distinct serological profiles and confirm that these

  6. Detection of anti-liver cytosol antibody type 1 (anti-LC1) by immunodiffusion, counterimmunoelectrophoresis and immunoblotting: comparison of different techniques.

    Science.gov (United States)

    Muratori, L; Cataleta, M; Muratori, P; Manotti, P; Lenzi, M; Cassani, F; Bianchi, F B

    1995-12-01

    Liver cytosol specific antibody type 1 (anti-LC1) was first described in a proportion of patients with liver/kidney microsomal antibody type 1 (anti-LKM1)-positive autoimmune hepatitis (AIH) and is routinely evaluated by immunodiffusion (ID). Using human liver cytosol as the source of antigen, we have used ID, counterimmunoelectrophoresis (CIE) and immunoblotting (IB), to test sera from 167 patients with documented chronic liver diseases of different etiology. 15 patients had antinuclear antibody (ANA) and/or smooth muscle antibody (SMA)-positive AIH, 13 had anti-LKM1-positive AIH, four had ANA/SMA/anti-LKM1-negative AIH, 76 had anti-LKM1-positive hepatitis C (recently renamed unclassified chronic hepatitis-UCH), 40 had chronic hepatitis C, 15 had chronic hepatitis B, and 4 had chronic hepatitis D. A precipitin line of identity with an anti-LC1 reference serum was detected both by ID and CIE in 16 patients: six with anti-LKM1-positive 'definite' AIH, four with ANA/SMA/anti-LKM1-negative 'definite' AIH, and six with anti-LKM1-positive UCH. By IB, 14 out of the 16 anti-LC1-positive sera (87.5%) reacted with a 58 kDa human liver cytosolic polypeptide, whereas three out of 16 (19%) recognised an additional 60 kDa band. Compared to ID, CIE is more economical in terms of both time and reagents and provides more clear-cut results. The 58 kDa reactivity by IB was detectable in nearly all CIE/ID anti-LC1-positive patients, was not found among CIE/ID anti-LC1-negative patients. In conclusion, CIE is the ideal screening test for the detection of anti-LC1, an autoantibody that can be regarded as an additional serological marker of AIH and is especially useful in ANA/SMA/anti-LKM1 negative cases.

  7. VHH Antibodies: Reagents for Mycotoxin Detection in Food Products

    Directory of Open Access Journals (Sweden)

    Jia Wang

    2018-02-01

    Full Text Available Mycotoxins are the toxic secondary metabolites produced by fungi and they are a worldwide public health concern. A VHH antibody (or nanobody is the smallest antigen binding entity and is produced by heavy chain only antibodies. Compared with conventional antibodies, VHH antibodies overcome many pitfalls typically encountered in clinical therapeutics and immunodiagnostics. Likewise, VHH antibodies are particularly useful for monitoring mycotoxins in food and feedstuffs, as they are easily genetic engineered and have superior stability. In this review, we summarize the efforts to produce anti-mycotoxins VHH antibodies and associated assays, presenting VHH as a potential tool in mycotoxin analysis.

  8. Anti-Taenia solium monoclonal antibodies for the detection of parasite antigens in body fluids from patients with neurocysticercosis.

    Science.gov (United States)

    Paredes, Adriana; Sáenz, Patricia; Marzal, Miguel W; Orrego, Miguel A; Castillo, Yesenia; Rivera, Andrea; Mahanty, Siddhartha; Guerra-Giraldez, Cristina; García, Hector H; Nash, Theodore E

    2016-07-01

    Neurocysticercosis (NCC), an infection of the brain by Taenia solium (Ts) cysts, is the most common cause of adult-onset epilepsy in developing countries. Serological testing consists primarily of varying methods to detect antibodies in body fluids and more recently antigen (Ag) detection assays to identify individuals or animals with viable parasites. Antigen assays currently in use employ monoclonal antibodies (mAbs) raised against T. saginata, which have known cross reactivity to animal cestodes but are highly specific in human samples. We produced, characterized and tested 21 mAbs raised against T. solium whole cyst antigens, vesicular fluid or excretory secretory products. Reactivity of the TsmAbs against specific cyst structures was determined using immunofluorescence and immunohistochemistry on histological sections of Ts muscle cysts. Four TsmAbs reacted to vesicular space alone, 9 to the neck and cyst wall, one to the neck and vesicular space and 7 to the neck, cyst wall and vesicular space. An in-house ELISA assay to detect circulating Ts antigen, using the TsmAbs as capture antibodies and a rabbit polyclonal anti-Ts whole cyst antibody as a detector antibody demonstrated that eight of the 21 TsmAbs detected antigens in known NCC-positive human sera and three of these also in urine samples. Reactivity was expressed as normalized ratios of optical densities (OD positive control/OD negative control). Three TsmAbs had ratios >10 and five between 2 and 10. The TsmAbs have potential utility for the diagnosis and post-treatment monitoring of patients with viable NCC infections. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Development of ELISA-detected anti-HLA antibodies precedes the development of bronchiolitis obliterans syndrome and correlates with progressive decline in pulmonary function after lung transplantation.

    Science.gov (United States)

    Jaramillo, A; Smith, M A; Phelan, D; Sundaresan, S; Trulock, E P; Lynch, J P; Cooper, J D; Patterson, G A; Mohanakumar, T

    1999-04-27

    Development of anti-HLA antibodies after lung transplantation (LT) is thought to play an important role in the etiology of bronchiolitis obliterans syndrome (BOS). However, a cause-effect relationship between anti-HLA antibodies and BOS has not been established. This study was conducted to determine the temporal relationship between the development of anti-HLA antibodies and BOS after LT, and to determine the antigenic specificity of the antibodies developed in BOS patients. Sera from 15 BOS+ LT patients and 12 BOS- LT patients were obtained before LT and collected again at 6, 12, 24, 36, and 48 months after LT. Anti-HLA antibodies were detected by the PRA-STAT ELISA system and by complement-dependent cytotoxicity assays. Anti-HLA reactivity was further characterized by flow cytometry and absorption/elution with human platelets. When analyzed by ELISA, 10 of 15 BOS+ patients developed anti-HLA antibodies, whereas 0 of 12 BOS- patients developed anti-HLA antibodies (PELISA after LT can provide an early identification of an important subset of LT patients with an increased risk of developing BOS.

  10. Development of an enzyme-linked immunosorbent assay for detection of IgM antibodies to Babesia bigemina in cattle

    Directory of Open Access Journals (Sweden)

    Ruiz Patrícia M Gonçalves

    2001-01-01

    Full Text Available A crude antigenic preparation of Babesia bigemina was used to develop an ELISA for the detection of IgM antibodies. Optimal dilutions of the antigen, using positive and negative reference sera, were determined by checkerboard titrations. Negative sera from cattle imported from tick-free areas, serum samples collected from infected B. bigemina cattle were used to validate the test. The specificity was 94% and sensitivity of the Elisa 87.5%. Sera from 385 cattle deriving from areas free from tick-borne diseases, which were submitted to a preimmunization process, were screened by this technique. The Elisa detected seroconversion on the 14th day post-inoculation in animals either infested with Boophilus microplus ticks (infected with B. bigemina, or inoculated with B. bigemina infected blood. Antibody titers decreased after day 33; however, all animals remained positive until the end of the experiment (124 days. The ELISA described may prove to be an appropriate serological test for the detection of IgM antibodies against B. bigemina.

  11. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    Science.gov (United States)

    Alderete, J F

    1984-06-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses during the development of lesions in animals inoculated subcutaneously and it reproducibly measured the individual classes immunoglobulins directed at T vaginalis. The colorimetric assay was also suitable for showing cross reactivity between trichomonal species as well as between different strains of T vaginalis. Conditions established for monitoring antibody to trichomanads in immunised rabbits or infected mice were equally effective for human materials, such as serum or vaginal washes. Serum from experimental animals or infected people showed high concentrations of IgG, IgA, and IgM antibody to trichomonads. Only antibodies of the IgG and IgA class were detected in vaginal washes from women with acute trichomoniasis. No IgE antibody to trichomonads was found under a variety of conditions in serum samples from patients or experimental animals.

  12. Rapid Active Assay for the Detection of Antibodies to West Nile Virus in Chickens

    National Research Council Canada - National Science Library

    Groves, Stephanie S; Turell, Michael J; Bailey, Charles L; Morozov, Victor N

    2008-01-01

    ... by detection of bound IgM molecules with functionalized magnetic beads as active labels. This assay takes only 15 minutes and has the same sensitivity as a commercially available human WNV IgM antibody-capture enzyme-linked immunosorbent assay...

  13. Influenza A plasma and serum virus antibody detection comparison in dogs using blocking enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    H. T. Lin

    2015-05-01

    Full Text Available Background and Aim: The influenza A virus (IAV is an important zoonotic pathogen with infections also reported in dogs. IAV infections can be detected through the presence of antibodies using the enzyme-linked immunosorbent assay (ELISA. Serum is the only standard sample source; however, there is no information on the availability of other sample sources for IAV antibody detection in dogs. Compared with serum, plasma is more widely employed in most animal hospitals. The object of this study is to investigate whether plasma collected in ethylenediaminetetraacetic acid (EDTA tubes (EDTA plasma or heparin tubes (heparin plasma could be used in the ELISA protocol instead of serum for IAV antibody detection in dogs. Materials and Methods: Totally, 82 matched EDTA plasma and serum sample pairs and 79 matched heparin plasma and serum sample pairs were employed using blocking enzyme-linked immunosorbent assay (bELISA. The agreement and correlation between the plasma (EDTA or heparin plasma and serum were assessed using the agreement index kappa (kD calculation and Pearson correlation coefficient, respectively. Results: The agreement index kD of EDTA plasma and serum was 1.0, and that of heparin plasma and serum was 0.85. The Pearson correlation coefficient of EDTA plasma and serum was 0.87 (p<0.01, and that of heparin plasma and serum was 0.82 (p<0.01. Conclusion: The results proved that plasma, especially EDTA plasma, could be substituted for serum in the bELISA test. This might greatly expand the clinical applicability of IAV antibody detection in dogs.

  14. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  15. Compositions, antibodies, asthma diagnosis methods, and methods for preparing antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hongjun; Zangar, Richard C.

    2017-01-17

    Methods for preparing an antibody are provided with the method including incorporating 3-bromo-4-hydroxy-benzoic acid into a protein to form an antigen, immunizing a mammalian host with the antigen, and recovering an antibody having an affinity for the antigen from the host. Antibodies having a binding affinity for a monohalotyrosine are provided as well as composition comprising an antibody bound with monohalotyrosine. Compositions comprising a protein having a 3-bromo-4-hydroxy-benzoic acid moiety are also provided. Methods for evaluating the severity of asthma are provide with the methods including analyzing sputum of a patient using an antibody having a binding affinity for monohalotyrosine, and measuring the amount of antibody bound to protein. Methods for determining eosinophil activity in bodily fluid are also provided with the methods including exposing bodily fluid to an antibody having a binding affinity for monohalotyrosine, and measuring the amount of bound antibody to determine the eosinophil activity.

  16. Iodoacetyl-functionalized pullulan: A supplemental enhancer for single-domain antibody-polyclonal antibody sandwich enzyme-linked immunosorbent assay for detection of survivin.

    Science.gov (United States)

    Matsushita, Takahiko; Arai, Hidenao; Koyama, Tetsuo; Hatano, Ken; Nemoto, Naoto; Matsuoka, Koji

    2017-11-01

    Survivin, an inhibitor of the apoptosis protein family, is a potent tumor marker for diagnosis and prognosis. The enzyme-linked immunosorbent assay (ELISA) is one of the methods that has been used for detection of survivin. However, ELISA has several disadvantages caused by the use of conventional antibodies, and we have therefore been trying to develop a novel ELISA system using camelid single-domain antibodies (VHHs) as advantageous replacements. Here we report a supplemental approach to improve the VHH-polyclonal antibody sandwich ELISA for survivin detection. Iodoacetyl-functionalized pullulan was synthesized, and its thiol reactivity was characterized by a model reaction with l-cysteine. The thiophilic pullulan was applied to an immunoassay asan additive upon coating of standard assay plates with an anti-survivin VHH fusion protein with C-terminal cysteine. The results showed that the mole ratio of the additive to VHH had a significant effect on the consequent response. Mole ratios of 0.07, 0.7, and 7 led to 90% lower, 15% higher, and 69% lower responses, respectively, than the response of a positive control in which no additive was used. The background levels observed in any additive conditions were as low as that of a negative control lacking both VHH and the additive. These results indicate the applicability of the thiol-reactive pullulan as a response enhancer to VHH-based ELISA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Enzyme-linked immunosorbent Assay for detecting of antibody to canine distemper virus

    Directory of Open Access Journals (Sweden)

    Sudarisman

    2006-03-01

    Full Text Available Serum neutralisation test (SNT has been established for evaluating canine distemper vaccination, but until now SNT was rarely used due to the need for continuous tissue culture facilities and requires 3 days to perform. For detecting antibody to canine distemper virus, an enzyme-linked immunosorbent assay (ELISA is relatively simple and rapid seroassay. ELISA for canine immunoglobulin (Ig G antibodies to canine distemper virus (CDV was developed by using Onderstepoort strain of canine distemper virus as coating antigen. Rabbit anti canine IgG labelled with horse radish peroxidase was used as the conjugate, while phenylenediamine dihydrochloride (OPD was used as the substrate. The ELISA results were then compared with the results of the SNT, using the sera of 312 random-source dogs from West Java. The two test-results had a high degree of correlation. Very few discrepancies occurred and most of these were at the lower limits of each test. When the sera were tested at 1 : 100 dilutions, there was a 95.5% agreement between the ELISA and SNT. Their sensitivity and spesificity were 83.9 and 98.4%. Titrated SNT and ELISA also were performed on sera from 7 dogs whose lifetime medical histories were known. The antibodies were inclining up after two months of post vaccination, where the titre was not in zero/lower position at the day of vaccination. However, antibody zero or low position were found at 28 days post vaccination. All of the results indicated that ELISA can be used for evaluating antibody to canine distemper virus response, replacing the SNT.

  18. Relation between enzyme-linked immunosorbent assay and radioimmunoassay for detection of antibodies to the capsular polysaccharide of Haemophilus influenzae type b

    International Nuclear Information System (INIS)

    Kristensen, K.; Weis Bentzon, M.

    1992-01-01

    The measurement of antibodies to the capsular polysaccharide (PRP) of Haemophilus influenzae type b (Hib) is important because vaccines inducing such antibodies are now available. We developed and evaluated an enzyme-linked immunosorbent assay (ELISA) for detection of these antibodies based on direct coating of the plates with tyraminated PRP. The assay fulfilled the requirements for parallel line assays; it was sensitive, specific, and reproducible with a coefficient of variation between days of 19%. Results from the ELISA were compared with results from radioimmunoassay and a correlation coefficient of 0.93 was found. Results obtained by the two methods were proportional and the relation was indepenedent of the antibody level. The relation between them was also unaffected by the contribution of different antibody isotypes, indicating that these were measured to the same extent by both methods. ELISA employing direct coating of the plates with tyraminated PRP represents a useful alternative for detection of antibodies when studying immunogenicity of Hib vaccines. (au)

  19. Polysaccharide microarray technology for the detection of Burkholderia pseudomallei and Burkholderia mallei antibodies.

    Science.gov (United States)

    Parthasarathy, Narayanan; DeShazer, David; England, Marilyn; Waag, David M

    2006-11-01

    A polysaccharide microarray platform was prepared by immobilizing Burkholderia pseudomallei and Burkholderia mallei polysaccharides. This polysaccharide array was tested with success for detecting B. pseudomallei and B. mallei serum (human and animal) antibodies. The advantages of this microarray technology over the current serodiagnosis of the above bacterial infections were discussed.

  20. Recommendations for the validation of cell-based assays used for the detection of neutralizing antibody immune responses elicited against biological therapeutics.

    Science.gov (United States)

    Gupta, Shalini; Devanarayan, Viswanath; Finco, Deborah; Gunn, George R; Kirshner, Susan; Richards, Susan; Rup, Bonita; Song, An; Subramanyam, Meena

    2011-07-15

    The administration of biological therapeutics may result in the development of anti-drug antibodies (ADAs) in treated subjects. In some cases, ADA responses may result in the loss of therapeutic efficacy due to the formation of neutralizing ADAs (NAbs). An important characteristic of anti-drug NAbs is their direct inhibitory effect on the pharmacological activity of the therapeutic. Neutralizing antibody responses are of particular concern for biologic products with an endogenous homolog whose activity can be potentially dampened or completely inhibited by the NAbs leading to an autoimmune-type deficiency syndrome. Therefore, it is important that ADAs are detected and characterized appropriately using sensitive and reliable methods. The design, development and optimization of cell-based assays used for detection of NAbs have been published previously by Gupta et al. 2007 [1]. This paper provides recommendations on best practices for the validation of cell-based NAb assay and suggested validation parameters based on the experience of the authors. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.

    Science.gov (United States)

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-12-01

    To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.

  2. [Effect comparison between two ELISA kits in IgG antibody detection of Echinococcus granulosus].

    Science.gov (United States)

    Chu, Yan-Hong; Cai, Yu-Chun; Ai, Lin; Lu, Yan; Zhang, Jia; Chen, Jia-Xu

    2013-06-01

    To compare the effects of two ELISA kits on IgG antibody detection of human Echinococcus granulosus. A Total of 134 sera of patients with echinococcosis, paragonimiasis westermani, clonorchiasis sinensis, schistosomiasis japonica, and cysticercosis cellulosae, and normal persons were detected by two IgG ELISA kits produced by different companies. Furthermore, the specificity, sensitivity and cross reactivity were counted and analyzed statistically. The sensitivity and specificity were extremely high of the two kits as 100.00%. The cross-reactivity rates were 25.00% (paragonimiasis westermani), 26.09% (clonorchiasis sinensis), 10.00% (schistosomiasis japonica), and 87.5% (cysticercosis), respectively, by using the kit produced by the Combined Company in Shenzhen; the cross-reactivity rates were 5.00% (paragonimiasis westermani), 13.04% (clonorchiasis sinensis), 20.00% (schistosomiasis japonica), and 93.75% (cysticercosis) respectively, by using the kit produced by Haitai Company in Zhuhai. In addition, there was a significant difference of Paragonimus westermani detection (P 0.05) between the two kits. Both ELISA kits on IgG antibody detection of human Echinococcus granulosus have the advantages of a high sensitivity, specificity, convenience and high-speed. However, it is also in urgent need to further solve the cross-reactivity of Echinococcus granulosus with other parasites, in order to improve the accuracy of early diagnosis.

  3. Production of monoclonal antibodies and development of a quantitative immuno-polymerase chain reaction assay to detect and quantify recombinant Glutathione S-transferase.

    Science.gov (United States)

    Abud, J E; Luque, E H; Ramos, J G; Rodriguez, H A

    2017-07-01

    GST-tagged proteins are important tools for the production of recombinant proteins. Removal of GST tag from its fusion protein, frequently by harsh chemical treatments or proteolytic methods, is often required. Thus, the monitoring of the proteins in tag-free form requires a significant effort to determine the remnants of GST during purification process. In the present study, we developed both a conventional enzyme-linked immunosorbent assay (ELISA) and an immuno-polymerase chain reaction (IPCR) assay, both specific for detection of recombinant GST (rGST). rGST was expressed in Escherichia coli JM109, using a pGEX4T-3 vector, and several anti-rGST monoclonal antibodies were generated using hybridoma technology. Two of these were rationally selected as capture and detection antibodies, allowing the development of a sandwich ELISA with a limit of detection (LOD) of 0.01 μg/ml. To develop the rGST-IPCR assay, we selected "Universal-IPCR" format, comprising the biotin-avidin binding as the coupling system. In addition, the rGST-IPCR was developed in standard PCR tubes, and the surface adsorption of antibodies on PCR tubes, the optimal neutravidin concentrations, the generation of a reporter DNA and the concentration effect were studied and determined. Under optimized assay conditions, the rGST-IPCR assay provided a 100-fold increase in the LOD as well as an expanded working range, in comparison with rGST-ELISA. The proposed method exhibited great potentiality for application in several fields in which measurement of very low levels of GST is necessary, and might provide a model for other IPCR assays. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Novel Phospholipid-Protein Conjugates Allow Improved Detection of Antibodies in Patients with Autoimmune Diseases.

    Directory of Open Access Journals (Sweden)

    Simone V Samuelsen

    Full Text Available Reliable measurement of clinically relevant autoimmune antibodies toward phospholipid-protein conjugates is highly desirable in research and clinical assays. To date, the development in this field has been limited to the use of natural heterogeneous antigens. However, this approach does not take structural features of biologically active antigens into account and leads to low reliability and poor scientific test value. Here we describe novel phospholipid-protein conjugates for specific detection of human autoimmune antibodies. Our synthetic approach includes mild oxidation of synthetic phospholipid cardiolipin, and as the last step, coupling of the product with azide-containing linker and copper-catalyzed click chemistry with β2-glycoprotein I and prothrombin. To prove utility of the product antigens, we used enzyme-linked immunosorbent assay and three cohorts of samples obtained from patients in Denmark (n = 34 and the USA (n = 27 and n = 14. Afterwards we analyzed correlation of the obtained autoantibody titers with clinical parameters for each patient. Our results prove that using novel antigens clinically relevant autoantibodies can be detected with high repeatability, sensitivity and specificity. Unlike previously used antigens the obtained autoantibody titers strongly correlate with high disease activity and in particular, with arthritis, renal involvement, anti-Smith antibodies and high lymphocyte count. Importantly, chemical composition of antigens has a strong influence on the correlation of detected autoantibodies with disease activity and manifestations. This confirms the crucial importance of antigens' composition on research and diagnostic assays, and opens up exciting perspectives for synthetic antigens in future studies of autoimmunity.

  5. Development of a fluorescent antibody method for the detection of Enterococcus faecium and its potential for coastal aquatic environment monitoring.

    Science.gov (United States)

    Caruso, Gabriella; Monticelli, L S; Caruso, R; Bergamasco, A

    2008-02-01

    A direct, microscopic fluorescent antibody method was developed to detect the occurrence of Enterococcus faecium in coastal aquatic environments and was compared with the conventional membrane filtering method. The "in situ" application of the antibody-based protocol in the analysis of water samples collected from coastal polyhaline habitats demonstrated good sensitivity and ease of implementation. Data obtained with the microscopic technique were in agreement with those obtained from culture counts. The fluorescent antibody method proved to be a rapid and reliable technique for the detection of E. faecium. The advantages and limitations intrinsic to the method are discussed, highlighting the potential of this new technique for monitoring coastal aquatic environments.

  6. Micro solid-phase radioimmunoassay for detection of herpesvirus type-specific antibody: parameters involved in standardization

    Energy Technology Data Exchange (ETDEWEB)

    Matson, D.O.; Adler-Storthz, K.; Adam, E.; Dreesman, G.R. (Baylor Univ., Houston, TX (USA). Coll. of Medicine)

    1983-02-01

    A micro solid-phase radioimmunoassay (micro-SPRIA) was developed to demonstrate type-specific antibodies to herpes simplex virus types 1 and 2 (HSV1 and HSV2). Glycoproteins from the 123,000 dalton region of HSV1 (VP123) and the 119,000 dalton region of HSV2 (VP119) were isolated on preparative polyacrylamide gels for use as antigens in the micro-SPRIA. Human sera selected from clinical samples by virological history and appropriate microneutralization data were used to standardize the micro-SPRIA. Optimization of the assay required the use of siliconized microtiter wells for adsorption of antigen. Maximized results were highly dependent on the concentrations of antigen, primary antibody, and secondary antibody as well as the diluents used for these principal test reagents. Incorporation of HSV glycoproteins of each respective type with the optimal condition established in this study facilitates the direct detection of type-specific antibody in human sera.

  7. [Detection of leptospira by culture of vitreous humor and detection of antibodies against leptospira in vitreous humor and serum of 225 horses with equine recurrent uveitis].

    Science.gov (United States)

    Dorrego-Keiter, Elisa; Tóth, József; Dikker, Lieke; Sielhorst, Jutta; Schusser, Gerald Fritz

    2016-01-01

    In the ongoing discussion regarding the aetiopathogenesis of equine recurrent uveitis (ERU) it was the aim of the present study to elucidate the relationship of leptospira infection and ERU. In a population of 225 horses leptospira were examined in vitreous humor by culture and leptospira antibody were detected in vitreous humor and serum samples. Preoperative serum samples were collected from 221/225 ERU patients of different age, gender and breed. Undiluted vitreous humor was aseptically taken from 198/225 patients that underwent pars plana vitrectomy at the beginning of surgery and from 27/225 patients' eyeball after enucleation: Serum and vitreous humor were tested for specific leptospiral antibodies by microscopic agglutination test (MAT). Furthermore, vitreous humor was examined by culture. 20 patients which were euthanized due to a live-threatening disease other than ERU served as a control group. A total of 127/221 (57.5%) horses had serum antibodies (≥ 1:100). Most frequently antibodies against L. interrogans serovar Grippotyphosa were detected (79/127), followed by L. interrogans serovar lcterohaemorrhagiae (34/127) and L. interrogans serovar Bratislava (29/127). Only 79/225 horses (35.1%) had leptospiral antibodies in vitreous humor, in which L. interrogans serovar Grippotyphosa (67/79) was identified most frequently followed by L. interrogans serovar Pomona (18/79) and L. interrogans serovar lcterohaemorrhagiae (8/79) which was identified as single or multiple reaction. Isolation of leptospira from vitreous humor was positive in 34/212 horses (16%). 10/20 control horses had a positive antibody titer against leptospira in serum and 2/20 horses in vitreous humor, whereas there was no leptospira detected in culture. The result of 84% negative cultures from vitreous humor of 212 ERU patients is decisive for the diagnosis and therapy of ERU.

  8. Antibody profiling sensitivity through increased reporter antibody layering

    Science.gov (United States)

    Apel, William A; Thompson, Vicki S

    2013-02-26

    A method for analyzing a biological sample by antibody profiling for identifying forensic samples or for detecting the presence of an analyte. In an embodiment of the invention, the analyte is a drug, such as marijuana, Cocaine (crystalline tropane alkaloid), methamphetamine, methyltestosterone, or mesterolone. The method comprises attaching antigens to a surface of a solid support in a preselected pattern to form an array wherein locations of the antigens are known; contacting the array with the biological sample such that a portion of antibodies in the sample reacts with and binds to the antigens in the array to form immune complexes; washing away antibodies that do form immune complexes; and detecting the immune complexes, to form an antibody profile. Forensic samples are identified by comparing a sample from an unknown source with a sample from a known source. Further, an assay, such as a test for illegal drug use, can be coupled to a test for identity such that the results of the assay can be positively correlated to the subject's identity.

  9. Antibody profiling sensitivity through increased reporter antibody layering

    Energy Technology Data Exchange (ETDEWEB)

    Apel, William A.; Thompson, Vicki S.

    2017-03-28

    A method for analyzing a biological sample by antibody profiling for identifying forensic samples or for detecting the presence of an analyte. In an embodiment of the invention, the analyte is a drug, such as marijuana, Cocaine (crystalline tropane alkaloid), methamphetamine, methyltestosterone, or mesterolone. The method comprises attaching antigens to a surface of a solid support in a preselected pattern to form an array wherein locations of the antigens are known; contacting the array with the biological sample such that a portion of antibodies in the sample reacts with and binds to the antigens in the array to form immune complexes; washing away antibodies that do form immune complexes; and detecting the immune complexes, to form an antibody profile. Forensic samples are identified by comparing a sample from an unknown source with a sample from a known source. Further, an assay, such as a test for illegal drug use, can be coupled to a test for identity such that the results of the assay can be positively correlated to the subject's identity.

  10. Antibody profiling sensitivity through increased reporter antibody layering

    Energy Technology Data Exchange (ETDEWEB)

    Apel, William A.; Thompson, Vicki S.

    2013-02-26

    A method for analyzing a biological sample by antibody profiling for identifying forensic samples or for detecting the presence of an analyte. In an embodiment of the invention, the analyte is a drug, such as marijuana, Cocaine (crystalline tropane alkaloid), methamphetamine, methyltestosterone, or mesterolone. The method comprises attaching antigens to a surface of a solid support in a preselected pattern to form an array wherein locations of the antigens are known; contacting the array with the biological sample such that a portion of antibodies in the sample reacts with and binds to the antigens in the array to form immune complexes; washing away antibodies that do form immune complexes; and detecting the immune complexes, to form an antibody profile. Forensic samples are identified by comparing a sample from an unknown source with a sample from a known source. Further, an assay, such as a test for illegal drug use, can be coupled to a test for identity such that the results of the assay can be positively correlated to the subject's identity.

  11. Antibody profiling sensitivity through increased reporter antibody layering

    Energy Technology Data Exchange (ETDEWEB)

    Apel, William A.; Thompson, Vicki S

    2010-04-13

    A method for analyzing a biological sample by antibody profiling for identifying forensic samples or for detecting the presence of an analyte. In an embodiment of the invention, the analyte is a drug, such as marijuana, Cocaine (crystalline tropane alkaloid), methamphetamine, methyltestosterone, or mesterolone. The method comprises attaching antigens to a surface of a solid support in a preselected pattern to form an array wherein locations of the antigens are known; contacting the array with the biological sample such that a portion of antibodies in the sample reacts with and binds to the antigens in the array to form immune complexes; washing away antibodies that do form immune complexes; and detecting the immune complexes, to form an antibody profile. Forensic samples are identified by comparing a sample from an unknown source with a sample from a known source. Further, an assay, such as a test for illegal drug use, can be coupled to a test for identity such that the results of the assay can be positively correlated to the subject's identity.

  12. Development of antibodies against the rat brain somatostatin receptor.

    Science.gov (United States)

    Theveniau, M; Rens-Domiano, S; Law, S F; Rougon, G; Reisine, T

    1992-05-15

    Somatostatin (SRIF) is a neurotransmitter in the brain involved in the regulation of motor activity and cognition. It induces its physiological actions by interacting with receptors. We have developed antibodies against the receptor to investigate its structural properties. Rabbit polyclonal antibodies were generated against the rat brain SRIF receptor. These antibodies (F4) were able to immunoprecipitate solubilized SRIF receptors from rat brain and the cell line AtT-20. The specificity of the interaction of these antibodies with SRIF receptors was further demonstrated by immunoblotting. F4 detected SRIF receptors of 60 kDa from rat brain and adrenal cortex and the cell lines AtT-20, GH3, and NG-108, which express high densities of SRIF receptors. They did not detect immunoreactive material from rat liver or COS-1, HEPG, or CRL cells, which do not express functional SRIF receptors. In rat brain, 60-kDa immunoreactivity was detected by F4 in the hippocampus, cerebral cortex, and striatum, which have high densities of SRIF receptors. However, F4 did not interact with proteins from cerebellum and brain stem, which express few SRIF receptors. Immunoreactive material cannot be detected in rat pancreas or pituitary, which have been reported to express a 90-kDa SRIF receptor subtype. The selective detection of 60-kDa SRIF receptors by F4 indicates that the 60- and 90-kDa SRIF receptor subtypes are immunologically distinct. The availability of antibodies that selectively detect native and denatured brain SRIF receptors provides us with a feasible approach to clone the brain SRIF receptor gene(s).

  13. Detection of Antibodies to Seven Priority Pathogens in Backyard Poultry in Trinidad, West Indies

    Directory of Open Access Journals (Sweden)

    Arianne Brown Jordan

    2018-01-01

    Full Text Available Backyard poultry farms in Trinidad and Tobago (T&T play a vital role in providing food and income for rural communities. There is currently no information on the presence and circulation of pathogens in backyard poultry farms in T&T, and little is known in relation to the potential risks of spread of these pathogens to the commercial poultry sector. In order to address this, serum samples were collected from 41 chickens on five backyard farms taken from selected locations in Trinidad. Samples were tested for antibodies to seven priority pathogens of poultry by enzyme-linked immunosorbent assay (ELISA. Antibodies were detected in 65% (CI 95%: 50–78% of the sampled birds for Infectious bronchitis virus (IBV, 67.5% (CI 95%: 52–80% for Infectious bursal disease virus (IBDV, 10% (CI 95%: 4–23% for Newcastle disease virus (NDV, 0% (CI 95%: 0–0% for Avian influenza virus (AIV, 0% (CI 95%: 0–0% for West Nile virus (WNV, 31.7% (CI 95%: 20–47% for Mycoplasm gallisepticum/synoviae and 0% (CI 95%: 0–0% for Salmonella enterica serotype Enteritidis. These results reveal the presence and circulation of important pathogens of poultry in selected backyard farms in Trinidad. The results provide important information which should be taken into consideration when assessing the risks of pathogen transmission between commercial and backyard poultry farms, as well as between poultry and wild birds.

  14. Detection of antibodies against Chlamydophila abortus in Costa Rican sheep flocks

    Directory of Open Access Journals (Sweden)

    R. Villagra-Blanco

    2015-09-01

    Full Text Available A total of 359 sheep samples from 15 flocks were analyzed for the presence of antibodies against Chlamydophila abortus using a commercial Enzyme linked Immunosorbent Assay (ELISA. Antibodies were detected in 19 (5.29% sheep from 12 (80% flocks. Seropositive animals were found in all analyzed regions (Central, Chorotega, Atlantic Huetar, North Huetar and Central Pacific determining prevalence between 0.28% and 4.4%, and intra-flock positivity between 3.7% and 25.0%. The survey revealed two risk factors associated with seropositivity; introducing animals (males and females, embryos, or semen from other farms or from abroad without any sanitary certification, and flocks not having quarantine areas or separated boxes for diseased animals. No clinical signs of disease were observed in positive seroreactors. C. abortus seems to be present in Costa Rica in a very low prevalence in sheep flocks. Further studies, to isolate the bacteria are required. Finally, implementation of control measures to prevent the spread of C. abortus is recommended.

  15. Detection of antibodies against Chlamydophila abortus in Costa Rican sheep flocks

    Science.gov (United States)

    Villagra-Blanco, R.; Dolz, G.; Montero-Caballero, D.; Romero-Zúñiga, J.J.

    2015-01-01

    A total of 359 sheep samples from 15 flocks were analyzed for the presence of antibodies against Chlamydophila abortus using a commercial Enzyme linked Immunosorbent Assay (ELISA). Antibodies were detected in 19 (5.29%) sheep from 12 (80%) flocks. Seropositive animals were found in all analyzed regions (Central, Chorotega, Atlantic Huetar, North Huetar and Central Pacific) determining prevalence between 0.28% and 4.4%, and intra-flock positivity between 3.7% and 25.0%. The survey revealed two risk factors associated with seropositivity; introducing animals (males and females), embryos, or semen from other farms or from abroad without any sanitary certification, and flocks not having quarantine areas or separated boxes for diseased animals. No clinical signs of disease were observed in positive seroreactors. C. abortus seems to be present in Costa Rica in a very low prevalence in sheep flocks. Further studies, to isolate the bacteria are required. Finally, implementation of control measures to prevent the spread of C. abortus is recommended. PMID:26623377

  16. Antibody mimetics: promising complementary agents to animal-sourced antibodies.

    Science.gov (United States)

    Baloch, Abdul Rasheed; Baloch, Abdul Wahid; Sutton, Brian J; Zhang, Xiaoying

    2016-01-01

    Despite their wide use as therapeutic, diagnostic and detection agents, the limitations of polyclonal and monoclonal antibodies have inspired scientists to design the next generation biomedical agents, so-called antibody mimetics that offer many advantages over conventional antibodies. Antibody mimetics can be constructed by protein-directed evolution or fusion of complementarity-determining regions through intervening framework regions. Substantial progress in exploiting human, butterfly (Pieris brassicae) and bacterial systems to design and select mimetics using display technologies has been made in the past 10 years, and one of these mimetics [Kalbitor® (Dyax)] has made its way to market. Many challenges lie ahead to develop mimetics for various biomedical applications, especially those for which conventional antibodies are ineffective, and this review describes the current characteristics, construction and applications of antibody mimetics compared to animal-sourced antibodies. The possible limitations of mimetics and future perspectives are also discussed.

  17. Immunoscintigraphic detection of infections using monoclonal antigranulocyte antibodies

    International Nuclear Information System (INIS)

    Seybold, K.

    1988-01-01

    We report on a new approach to in vivo labelling of granulocytes for scintigraphic detection of infections by using the I-123 tagged monoclonal anti-CEA antibody-47 (Mab 47). Mab 47 reacts selectively with a glycoprotein (NAC 95) present on the surface of mature granulocytes. Many in vitro tests showed that binding does not inhibit granulocyte functions (e.g. chemotaxis, initiation of 'burst'). Up till now we have performed the search for infectious lesions in 56 patients. For clinical use one dose consisted of 120 mcg Mab 47 labelled with 148-185 MBq I-123 (specific activity: 1.85 GBq/mg). We noticed that all infectious lesions were highly visible 3-6 hours after tracer infusion or could be excluded after 24 h. High counting rates permitted SPECT-studies up to 24 h p.i. which are very usefull for an exact topographic localization of a lesion. The clinical interest was concentrated on cases of bone and joint infections. It is concluded that there are distinct advantages of the new method compared with In-111 WBC scanning. Without the need for cell separation there is a rapid in vivo labelling of granulocytes so that the method is also suitable in very acute cases. No allergic reactions have been observed. In spite of these obvious advantages and the low administered dose of antibodies we recommend a restriction in immunscintigraphy of infections because of the unknown antigenicity of the compound. (orig.) [de

  18. Comparison of cell-based and non-cell-based assay platforms for the detection of clinically relevant anti-drug neutralizing antibodies for immunogenicity assessment of therapeutic proteins.

    Science.gov (United States)

    Hu, Jenny; Wala, Iwona; Han, Hong; Nagatani, Janice; Barger, Troy; Civoli, Francesca; Kaliyaperumal, Arunan; Zhuang, Yao; Gupta, Shalini

    2015-04-01

    Anti-drug neutralizing antibodies (NAbs) formed due to unwanted immunogenicity of a therapeutic protein point towards a mature immune response. NAb detection is important in interpreting the therapeutic's efficacy and safety in vivo. In vitro cell-based NAb assays provide a physiological system for NAb detection, however are complex assays. Non-cell-based competitive ligand binding (CLB) approaches are also employed for NAb detection. Instead of cells, CLB assays use soluble receptor and conjugated reagents and are easier to perform, however have reduced physiological relevance. The aim of this study was to compare the performance of CLB assays to established cell-based assays to determine the former's ability to detect clinically relevant NAbs towards therapeutics that (i) acted as an agonist or (ii) acted as antagonists by binding to a target receptor. We performed a head-to-head comparison of the performance of cell-based and CLB NAb assays for erythropoietin (EPO) and two anti-receptor monoclonal antibodies (AMG-X and AMG 317). Clinically relevant NAb-positive samples identified previously by a cell-based assay were assessed in the corresponding CLB format(s). A panel of 12 engineered fully human anti-EPO monoclonal antibodies (MAbs) was tested in both EPO NAb assay formats. Our results showed that the CLB format was (i) capable of detecting human anti-EPO MAbs of differing neutralizing capabilities and affinities and (ii) provided similar results as the cell-based assay for detecting NAbs in patient samples. The cell-based and CLB assays also behaved comparably in detecting NAbs in clinical samples for AMG-X. In the case of anti-AMG 317 NAbs, the CLB format failed to detect NAbs in more than 50% of the tested samples. We conclude that assay sensitivity, drug tolerance and the selected assay matrix played an important role in the inability of AMG 317 CLB assays to detect clinically relevant NAbs. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Detection of Antibodies to Brucella Cytoplasmic Proteins in the Cerebrospinal Fluid of Patients with Neurobrucellosis

    Science.gov (United States)

    Baldi, Pablo C.; Araj, George F.; Racaro, Graciela C.; Wallach, Jorge C.; Fossati, Carlos A.

    1999-01-01

    The diagnosis of human neurobrucellosis usually relies on the detection of antibodies to Brucella lipopolysaccharide (LPS) in cerebrospinal fluid (CSF) by agglutination tests or enzyme-linked immunosorbent assay (ELISA). Here we describe the detection of immunoglobulin G (IgG) to cytoplasmic proteins (CP) of Brucella spp. by ELISA and Western blotting in seven CSF samples from five patients with neurobrucellosis. While IgG to CP (titers of 200 to 12,800) and IgG to LPS (800 to 6,400) were found in the CSF of these patients, these antibodies were not detected in CSF samples from two patients who had systemic brucellosis without neurological involvement. The latter, however, had serum IgG and IgM to both LPS and CP. No reactivity to these antigens was found in CSF samples from 14 and 20 patients suffering from nonbrucellar meningitis and noninfectious diseases, respectively. These findings suggest that, in addition to its usefulness in the serological diagnosis of human systemic brucellosis, the ELISA with CP antigen can be used for the specific diagnosis of human neurobrucellosis. PMID:10473531

  20. Purification of immunoreactive radiolabeled moniclonal antibodies with anti-iodiotypic moniclonal antibodies

    International Nuclear Information System (INIS)

    Temponi, M.; Pupa, S.; Ferrone, S.

    1990-01-01

    A method is described to purify immunoreactive moniclonal antibodies from radiolabeled monoclonal antibody preparations. The method is based on incubation of radiolabeled monoclonal antibodies with insolubilized anti-idiotypic monoclonal antibodies to idiotopes within the antigen-combining site of monoclonal antibodies to be purified an elution of bound monoclonal antibodies with a low pH buffer. The immunoreactive fraction of the purified monoclonal antibodies was at least 82%; the yeald was at least 73%. The purification procedure did not cause any detectable change in the affinity constant of the eluted monoclonal antibodies. The method is simple and rapid; the requirement for anti-idiotypic monoclonal antibodies to idiotopes within the antigen-combining site of the antibodies to be purified is not likely to represent a major limitation in the broad application of the present method, since the hybridoma technology has greatly facilitated the development of anti-idiotypic monoclonal antibodies. (author). 12 refs.; 4 figs.; 1 tab

  1. High-throughput sequencing of natively paired antibody chains provides evidence for original antigenic sin shaping the antibody response to influenza vaccination.

    Science.gov (United States)

    Tan, Yann-Chong; Blum, Lisa K; Kongpachith, Sarah; Ju, Chia-Hsin; Cai, Xiaoyong; Lindstrom, Tamsin M; Sokolove, Jeremy; Robinson, William H

    2014-03-01

    We developed a DNA barcoding method to enable high-throughput sequencing of the cognate heavy- and light-chain pairs of the antibodies expressed by individual B cells. We used this approach to elucidate the plasmablast antibody response to influenza vaccination. We show that >75% of the rationally selected plasmablast antibodies bind and neutralize influenza, and that antibodies from clonal families, defined by sharing both heavy-chain VJ and light-chain VJ sequence usage, do so most effectively. Vaccine-induced heavy-chain VJ regions contained on average >20 nucleotide mutations as compared to their predicted germline gene sequences, and some vaccine-induced antibodies exhibited higher binding affinities for hemagglutinins derived from prior years' seasonal influenza as compared to their affinities for the immunization strains. Our results show that influenza vaccination induces the recall of memory B cells that express antibodies that previously underwent affinity maturation against prior years' seasonal influenza, suggesting that 'original antigenic sin' shapes the antibody response to influenza vaccination. Published by Elsevier Inc.

  2. Human monoclonal antibody 99mTc-88BV59: detection of colorectal cancer, recurrent or metastatic disease and immunogenicity assessment.

    Science.gov (United States)

    Krause, B J; Baum, R P; Staib-Sebler, E; Lorenz, M; Niesen, A; Hör, G

    1997-01-01

    This study presents immunoscintigraphic results in 24 patients suffering from primary colorectal cancer, recurrent or metastatic disease after the injection of 1197-1351 MBq technetium-99m labelled totally human monoclonal antibody 88BV59. Labelling efficacy of 99mTc-88BV59 ranged from 97% to 99%. Immunoscintigraphy was performed 18-20 h after injection. Scintigraphic findings were compared with those of computed tomography (CT). Patients underwent surgery in order to evaluate immunoscintigraphic findings histologically. Sera of the patients (before injection and 1 and 3 months post infusion) were analysed for the presence of human anti-human antibodies (HAHA). None of the patients showed a HAHA response as assessed by a solid-phase ELISA assay. The antibody scan detected about 25% more lesions than CT. In the detection of extrahepatic disease, the sensitivity of the antibody scan proved to be 68%, whereas the sensitivity of CT was 41%.

  3. Clinical significance of combined detection of multiple serum antibodies (AsAb, EmAb, AcAb, AoAb, ToxAb) in infertile women

    International Nuclear Information System (INIS)

    Chen Jing; Jiang Li; Lu Ya

    2005-01-01

    Objective: To determine the clinical significance of combined detection of multiple serum antibodies in infertile women. Methods; Serum multiple antibodies were examined in 120 infertile women, including 88 failed to get pregnancy and 32 with repeated spontaneous abortion. The antibodies tested were: (1) anti-sperm antibody (AsAb) (2) endometrial antibody (EmAb) (3) anti-cardiophospholipid antibody (AcAb) (4) Anti-ovarian antibody (AoAb) and Toxoplasmosis antibody (ToxAb). Results: In 48 of the infertile women, none of the five antibodies were positive (40% of 120). The rest were: one antibody positive--38/120 or 31.6%; two antibodies positive--31/120 or 25.83%, three and four antibodies positive--4/120 or 3.33%. None of the women were positive with all five antibodies. Conclusion: Immune factor was the chief cause of infertility in women. (authors)

  4. [Western Blot diagnostic yield for simultaneous antibody-detection in patients with human cysticercosis, hydatidosis, and human fascioliasis].

    Science.gov (United States)

    Davelois, Kelly; Escalante, Hermes; Jara, César

    2016-01-01

    . To determine the diagnostic yield using western blotting to simultaneously detect antibodies in patients with human cysticercosis, hydatidosis, and human fascioliasis. Materials and methods . Cross-sectional study of diagnostic yield assessment. Excretory/secretory antigens were obtained from Taenia solium larvae, Echinococcus granulosus cysts, and the adult flukes of Fasciola hepática, which were then separated using the polyacrylamide gel electrophoresis technique, transferred, and attached to a nitrocellulose membrane to be probed with sera from the patient infected with the three parasites. The sensitivity of the technique was assessed using 300 individual serum samples, 60 pools of two parasites, and 20 pools of three parasites with 75 sera from patients with other parasites, 10 from patients with other diseases, and 15 from patients without parasites. Results . The technique revealed 13 glycoproteins (GP): GP 35, 31, 24, 23, 18, 17, 14, and 13 kDa for cysticercosis; GP 8, 16, and 21 kDa for hydatidosis; and GP 17 and 23 kDa for fascioliasis. The test detected the presence of antibodies with a sensitivity of 96% (95% confidence interval [CI] = 94.62-98.54%) in the detection of one or the thirteen bands, a specificity of 100% (95% CI = 99.50-100.00%); individually, there was a sensitivity for cysticercosis of 97% (95% CI = 93.16-100.00%), for hydatidosis of 94% (95% CI = 88.85-99.15%) and for fascioliasis of 96% (95% CI = 91.66-100.00%). Conclusions . Western blotting is effective in the simultaneous detection of antibodies in patients with human cysticercosis, hydatidosis, and fascioliasis, and it can be used as a diagnostic test to either rule out or confirm the presence of antibodies in endemic areas.

  5. Development of a monoclonal antibody-based sandwich-type enzyme-linked immunosorbent assay (ELISA) for detection of abrin in food samples.

    Science.gov (United States)

    Zhou, Yu; Tian, Xiang-Li; Li, Yan-Song; Pan, Feng-Guang; Zhang, Yuan-Yuan; Zhang, Jun-Hui; Wang, Xin-Rui; Ren, Hong-Lin; Lu, Shi-Ying; Li, Zhao-Hui; Liu, Zeng-Shan; Chen, Qi-Jun; Liu, Jing-Qiu

    2012-12-15

    Abrin is a plant toxin, which can be easily isolated from the seeds of Abrus precatorius. It may be used as a biological warfare agent. In order to detect abrin in food samples, a two-layer sandwich format enzyme-linked immunosorbent assay based on the monoclonal antibody (mAb) (as capture antibody) and rabbit polyclonal serum (as detecting antibody) was developed and applied for the determination of abrin in some food matrices. The linear range of the mAb was 1-100 μg L(-1) with a detection limit of 0.5 μg L(-1) for abrin in phosphate buffered saline (PBS). The recoveries of abrin from sausage, beer and milk samples ranged 97.5-98.6%, 95.8-98.4% and 94.8-9.6%, respectively, with a coefficient of variation (CV) of 3.7% or less. The newly developed sandwich ELISA using the mAb appears to be a reliable and useful method for detection of abrin in sausage, beer and milk. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Detection of antibodies to Actinobacillus pleuropneumoniae serotype 12 in pig serum using a blocking enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Andresen, Lars Ole; Klausen, Joan; Barfod, Kristen

    2002-01-01

    and from herds declared free of infection with Ap. The Ap serotype 12 blocking ELISA showed a herd sensitivity of 0.77 (95% confidence interval, 0.62-0.88) and a herd specificity of 1.00 (0.95-1.00) with a cut-off value at 40% relative absorbance or 60% inhibition. The assay may be used advantageously......The objective was to develop a blocking enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to Actinobacillus pleuropneumoniae (Ap) serotype 12 in pig serum. Lipopolysaccharide (LPS) from Ap serotype 12 was purified and used as antigen in the assay. Antibodies to the LPS antigen...... in samples of pig serum were detected by inhibition of the binding of polyclonal rabbit antibodies raised against Ap serotype 12. The assay was evaluated against sera from experimentally infected pigs, from pig herds naturally infected with Ap and from herds declared free of Ap serotypc 12 infection...

  7. Surface modification of polyacrylonitrile fiber for immobilization of antibodies and detection of analyte

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Swati, E-mail: swatijain.iitd@gmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Chattopadhyay, Sruti, E-mail: srutic@hotmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Jackeray, Richa, E-mail: richajackeray.iitd@gmail.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India); Singh, Harpal, E-mail: harpal2000@yahoo.com [Center for Biomedical Engineering, Indian Institute of Technology, New Delhi, 110016 (India)

    2009-11-10

    Pendent nitrile groups of multifilamentous polyacrylonitrile (PAN) fibers were reduced to amino groups using lithium aluminum hydride for different time of reduction and amine content was estimated by performing acid-base titrations. Attenuated total reflection-fourier transform infrared spectroscopy (ATR-FTIR) and Differential Scanning Calorimetry (DSC) were used for the characterization of the generated amino groups and thermal properties of the reduced fibers, respectively. The surface morphology of the fibers after reduction and immobilization was characterized using Scanning Electron Microscope (SEM). The newly formed amino groups of the fibers were activated by using glutaraldehyde for the covalent linking of Goat anti-Rabbit IgG-HRP (GAR-HRP) antibody enzyme conjugate. Modified PAN fibers were evaluated as a matrix for sandwich ELISA by using Goat anti-Rabbit antibody (GAR-IgG), Rabbit anti-Goat (RAG-IgG) as analyte and enzyme conjugate GAR-HRP. The fibers reduced for 24 h were able to detect the analyte RAG-IgG at a concentration as low as 3.75 ng mL{sup -1} with 12% skimmed milk as blocking reagent for the optimized concentration of primary antibody GAR-IgG 3 {mu}g mL{sup -1} and peroxidase conjugate GAR-HRP dilution of 8000 fold. The sensitivity, specificity and reproducibility of the developed immunoassay was further established with antibodies present in human blood using Rabbit anti-Human (RAH-IgG) antibody and the corresponding HRP enzyme conjugate. As low as 0.1 {mu}L of human blood was sufficient to perform the assay with the modified fibers.

  8. Validation of an indirect ELISA for the detection of Trypanosoma congolense antibodies in Ethiopian cattle

    International Nuclear Information System (INIS)

    Tadesse, Y.; Kefyalew, H.; Kembata, G.; Nega, A.

    2000-01-01

    Control and eradication of African Animal Trypanosomosis can be achieved if the reliability of the methods to diagnose the disease could be improved. The techniques currently used in the diagnosis of trypanosomosis in Ethiopia are not sufficiently sensitive to detect all infected animals. In order to improve disease diagnosis the indirect antibody detection ELISA, developed by FAO/IAEA, was evaluated under field conditions. Accordingly, reference serum samples were collected from trypanosomosis free and endemic areas. Serum samples negative for trypanosomes were collected from the Central highlands of Ethiopia where there is no previous record of trypanosomosis. The samples were used to establish the threshold and the specificity of the test. Trypanosoma congolense positive sera (based on thin and thick smears and BCT) were collected from endemic areas in the Southwestern part of the country to estimate the sensitivity of the test. Out of 701 negative serum samples, 690 were identified as negative with the indirect antibody ELISA, whereas the remaining 11 were detected as positive. Moreover, of the 282 infected samples the ELISA detected 155 sera as positive, but the remaining 127 cases fell in the negative range. The positive/negative threshold established from negative reference sera was found to be 81.38%. Based on this threshold the specificity of the test was 98.43%, whilst the sensitivity was calculated as 54.96%. Thus, the complementary use of both the ELISA and parasitological methods is encouraged. Since the internal quality controls (IQC) did not fall in the ranges prescribed in the protocol provided by FAO/IAEA precision was achieved by comparing the plate to plate variation of the IQC based on the means plot. Accordingly the assay process indicated that there was no significant difference between individual mean of each plate regarding the strong positive (C++) and moderate positive (C+) controls. Nevertheless, considerable discrepancies were

  9. Part-per-trillion level detection of estradiol by competitive fluorescence immunoassay using DNA/dye conjugate as antibody multiple labels.

    Science.gov (United States)

    Zhu, Shengchao; Zhang, Qin; Guo, Liang-Hong

    2008-08-22

    Fluorescent organic dyes are currently the standard signal-generating labels used in microarray quantification. However, new labeling strategies are needed to meet the demand for high sensitivity in the detection of low-abundance proteins and small molecules. In this report, a long-chain DNA/dye conjugate was used to attach multiple fluorescence labels on antibodies to improve signal intensity and immunoassay sensitivity. Compared with the 30 base-pair (bp) oligonucleotide used in our previous work [Q. Zhang, L.-H. Guo, Bioconjugate Chem. 18 (2007) 1668-1672], conjugation of a 219 bp DNA in solution with a fluorescent DNA binder SYBR Green I resulted in more than sixfold increase in signal intensity, consistent with the increase in bp number. In a direct immunoassay for the detection of goat anti-mouse IgG in a mouse IgG-coated 96-well plate, the long DNA conjugate label also produced higher fluorescence than the short one, accompanied by about 15-fold improvement in the detection limit. To demonstrate its advantage in real applications, the DNA/dye conjugate was employed in the competitive immunoassay of 17beta-estradiol, a clinically and environmentally important analyte. The biotin-terminated DNA was attached to biotinylated anti-estradiol antibody through the biotin/streptavidin/biotin bridge after the immuno-reaction was completed, followed by conjugation with SYBR Green I. The limit of detection for 17beta-estradiol is 1.9 pg mL(-1), which is 200-fold lower than the assay using fluorescein-labeled antibodies. The new multiple labeling strategy uses readily available reagents, and is also compatible with current biochip platform. It has great potential in the sensitive detection of protein and antibody microarrays.

  10. Development and evaluation of an immunochromatographic strip test based on the recombinant UL51 protein for detecting antibody against duck enteritis virus

    Directory of Open Access Journals (Sweden)

    Sun Tao

    2010-10-01

    Full Text Available Abstract Background Duck enteritis virus (DEV infection causes substantial economic losses to the worldwide duck-producing areas. The monitoring of DEV-specific antibodies is a key to evaluate the effect of DEV vaccine and develop rational immunization programs. Thus, in this study, an immunochromatographic strip (ICS test was developed for detecting DEV serum antibodies. Results The ICS test is based on membrane chromatography, and uses both the purified recombinant UL51 protein conjugated with colloidal gold and goat anti-rabbit IgG conjugated with colloidal gold as tracers, the purified recombinant UL51 protein as the capture reagent at the test line, and rabbit IgG as the capture reagent at the control line. The specificity of the ICS was evaluated by sera against DEV, Duck hepatitis virus (DHV, Riemerella anatipestifer (RA, Duck E. coli, Muscovy duck parvovirus (MPV, or Duck Influenza viruses (DIV. Only sera against DEV showed the strong positive results. In order to determine the sensitivity of the ICS, anti-DEV serum diluted serially was tested, and the minimum detection limit of 1:128 was obtained. The ICS components, which are provided in a sealed package, require no refrigeration and are stable for 12 months. To evaluate the effect of the ICS, 110 duck serum samples collected from several non-immune duck flocks were simultaneously tested by the ICS test, enzyme-linked immunosorbent assay (ELISA and neutralization test (NT. The results showed that the sensitivity of the ICS test was almost consistent with ELISA and much higher than NT, has low cost, and is rapid (15 min and easy to perform with no requirement of specialized equipment, reagent or technicians. Conclusions In this work, we successfully developed a simple and rapid ICS test for detecting DEV serum antibodies for the first time. The ICS test was high specific and sensitive for the rapid detection of anti-DEV antibodies, and has great potential to be used for the serological

  11. Simultaneous detection of IgG antibodies associated with viral hemorrhagic fever by a multiplexed Luminex-based immunoassay.

    Science.gov (United States)

    Wu, Wei; Zhang, Shuo; Qu, Jing; Zhang, Quanfu; Li, Chuan; Li, Jiandong; Jin, Cong; Liang, Mifang; Li, Dexin

    2014-07-17

    Viral hemorrhagic fevers (VHFs) are worldwide diseases caused by several kinds of viruses. With the emergence of new viruses, advanced diagnostic methods are urgently needed for identification of VHFs. Based on Luminex xMAP technology, a rapid, sensitive, multi-pathogen and high-throughput method which could simultaneously detect hemorrhagic fever viruses (HFVs) specific IgG antibodies was developed. Recombinant antigens of nine HFVs including Hantaan virus (HTNV), Seoul virus (SEOV), Puumala virus (PUUV), Andes virus (ANDV), Sin Nombre virus (SNV), Crimean-Congo hemorrhagic fever virus (CCHFV), Rift Valley fever virus (RVFV), Severe fever with thrombocytopenia syndrome bunyavirus (SFTSV) and dengue virus (DENV) were produced and purified from a prokaryotic expression system and the influence of the coupling amount was investigated. Cross-reactions among antigens and their rabbit immune sera were evaluated. Serum samples collected from 51 laboratory confirmed hemorrhagic fever with renal syndrome (HFRS) patients, 43 confirmed SFTS patients and 88 healthy donors were analyzed. Results showed that recombinant nucleocapsid protein of the five viruses belonging to the genus Hantavirus, had serological cross-reactivity with their corresponding rabbit immune sera, but not apparent with immune sera of other four viruses. Evaluation of this new method with clinical serum samples showed 98.04% diagnostic sensitivity for HFRS, 90.70% for SFTS detection and the specificity was ranging from 66.67% to 100.00%. The multiplexed Luminex-based immunoassay has firstly been established in our study, which provides a potentially reliable diagnostic tool for IgG antibody detection of VHFs. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Human monoclonal antibody 99mTc-88BV59: detection of colorectal cancer, recurrent or metastatic disease and immunogenicity assessment

    International Nuclear Information System (INIS)

    Krause, B.J.; Baum, R.P.; Staib-Sebler, E.; Lorenz, M.; Niesen, A.; Hoer, G.

    1997-01-01

    This study presents immunoscintigraphic results in 24 patients suffering from primary colorectal cancer, recurrent or metastatic disease after the injection of 1197-1351 MBq technetium-99m labelled totally human monoclonal antibody 88BV59. Labelling efficacy of 99m Tc-88BV59 ranged from 97% to 99%. Immunoscintigraphy was performed 18-20 h after injection. Scintigraphic findings were compared with those of computed tomography (CT). Patients underwent surgery in order to evaluate immunoscintigraphic findings histologically. Sera of the patients (before injection and 1 and 3 months post infusion) were analysed for the presence of human anti-human antibodies (HAHA). None of the patients showed a HAHA response as assessed by a solid-phase ELISA assay. The antibody scan detected about 25% more lesions than CT. In the detection of extrahepatic disease, the sensitivity of the antibody scan proved to be 68%, whereas the sensitivity of CT was 41%. (orig.). With 3 figs., 1 tab

  13. Development of a immunochromatographic test with avidin-biotin for the detection of antibodies against antigen e of hepatitis B in human plasma

    International Nuclear Information System (INIS)

    Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Diaz Argudin, Tamara

    2007-01-01

    The disappearance of antigen e of hepatitis B in the presence of the plasmatic antibodies against antigen e may indicate a satisfactory therapeutic response in patients with chronic hepatitis B. The immuno-chromatographic test carried out in the diagnosis of diseases use different antibody combinations and may employ the avidin or streptavidin-biotin technology to develop a rapid immuno-chromatographic test for the detection of antibodies anti-antigen e in the plasma. They were detected in the laboratory by means of two fast immuno-chromatographic tests when using in one of them the avidin-biotin technology. These tests are carried out with a one-step competitive inhibition format and amplified or not with avidin-biotin. Monoclonal antibodies against antigen e obtained by cellular hybridization were used. Forty-six plasmatic samples classified as positive and negative to the anti-antigen antibodies were evaluated with a reference immunochromatographic test Advanced QualityTM. The possible expiry time of the biological reagents forming part of these tests were studied with accelerated thermal-stability experiments. The possible interference in the plasma of some of the biochemical compounds used in these trials was analyzed. Four murine monoclonal antibodies anti-antigen e were obtained and only one of them was used in these immunochromatographic tests with an anti-antigen polyclonal antibody conjugated with gold. Both tests and their stable biological reagents discriminated the positive and negative samples to the antibodies anti-antigen e, as well as the commercial test. There was no interference in the biochemical compounds studied in these tests. Both immuno-chromatographic tests made in the laboratory are useful to detect antibodies anti-antigen e in the plasma. The avidin-biotin increased the analytical sensitivity of this type of fast immuno-chromatographic test without altering its performance features. (Author)

  14. Monoclonal antibodies in oncology. Review article

    Energy Technology Data Exchange (ETDEWEB)

    Chan, S Y.T.; Sikora, K

    1986-05-01

    Monoclonal antibodies (MCAs) can be used to differentiate between normal and neoplastic cells and thus exploited for diagnostic and, ultimately, therapeutic gain. The evidence for the existence of human tumour antigens is reviewed. Several areas of diagnosis are already benefiting from the application of the monoclonal technology. Immunohistology can help the pathologist with difficult diagnostic problems. New classifications of lymphoma and leukaemia can be based on specific surface molecules. Similarly, the detection of shed tumour antigens is already established as part of the routine assessment of many patients with common solid tumours. Isotopically labeled monoclonal antibodies have been used to localise primary and metastatic tumours. The use of antibodies in this way is not only a promising diagnostic tool but also the first step in studying the possibility of arming antibodies to provide therapeutic agents. Such trials are currently in progress. 69 refs.; 7 figs.; 3 tabs.

  15. Antibodies against linear epitopes on Goodpasture autoantigen in patients with anti-neutrophil cytoplasmic antibody-associated vasculitis.

    Science.gov (United States)

    Jia, Xiao-Yu; Yu, Jun-Tao; Hu, Shui-Yi; Li, Jian-Nan; Wang, Miao; Wang, Chen; Chen, Min; Cui, Zhao; Zhao, Ming-Hui

    2017-09-01

    In a substantial number of patients with crescentic glomerulonephritis, both anti-glomerular basement membrane (GBM) antibodies and anti-neutrophil cytoplasmic antibodies (ANCA) are detected simultaneously. ANCA is presumed to be the initial event but the mechanism is unknown. In the present study, we investigated the antibodies against linear epitopes on Goodpasture autoantigen in sera from patients with ANCA-associated vasculitis, aiming to reveal the mechanisms of the coexistence of the two kinds of autoantibodies. Thirty-one patients with ANCA-associated vasculitis were enrolled in this study. Twenty-four overlapping linear peptides were synthesized across the whole sequence of Goodpasture autoantigen. Serum antibodies against linear peptides were detected by ELISA and their associations with clinical features were further analyzed. Twenty-five out of the thirty-one (80.6%) sera from patients with ANCA-associated vasculitis possessed antibodies against linear peptides on Goodpasture autoantigen. These antibodies could be detected in 50% of patients with normal renal function (Scr ≤ 133 μmol/L), 70% of patients with moderate renal dysfunction (133 μmol/L  600 μmol/L) (P = 0.032). The highest recognition frequencies were found for peptides P4 (51.6%), P14 (54.8%), and P24 (54.8%), which contained the sequences that constitute the conformational epitopes of E A (P4) and E B (P14) recognized by anti-GBM antibodies. The level of anti-P4 antibodies was positively correlated with the percentage of crescents in glomeruli (r = 0.764, P = 0.027). Patients with anti-P24 antibodies had a significantly higher prevalence of renal dysfunction on diagnosis (88.2 vs. 42.9%, P = 0.018). Antibodies against linear epitopes on Goodpasture autoantigen could be detected in sera of patients with ANCA-associated vasculitis, which might mediate the production of antibodies towards the conformational epitopes on Goodpasture autoantigen, namely, the anti-GBM antibodies.

  16. Anti-smooth muscle antibody

    Science.gov (United States)

    ... gov/ency/article/003531.htm Anti-smooth muscle antibody To use the sharing features on this page, please enable JavaScript. Anti-smooth muscle antibody is a blood test that detects the presence ...

  17. Radioimmunoassay for antigliadin-antibodies using 14C-labelled gliadin

    International Nuclear Information System (INIS)

    Menzel, J.

    1977-01-01

    A sensitive radioimmunoassay for antibodies to gliadin has been developed. Gliadin from wheat gluten was labelled with [1- 14 C]acetic anhydride to a specific activity of 2.6 x 10 6 dpm/mg. Immunological evidence is presented that the antigen was not essentially altered by the labelling procedure. Experimentally-induced antigliadin antibodies or sera of patients with coeliac disease (CD) were reacted with labelled gliadin and the immune complexes formed precipitated by antiglobulin. Precipitating antibodies were determined by incubating CD sera with labelled gliadin and measuring the radioacticity in precipitates formed without the addition of second antibody. Comparison with other methods for the detection of antigliadin antibodies, including immunoelectrophoresis, immunodiffusion and passive hemagglutination indicated that total and precipitating antibodies were determined only by RIA. The assay also provides information on the immunoglobulin class of antigliadin-antibodies present in sera of patients with coeliac disease

  18. Tumor imaging with monoclonal antibodies

    International Nuclear Information System (INIS)

    Haisma, H.; Hilgers, J.

    1987-01-01

    Many monoclonal antibodies directed against tumor-associated antigens have been identified, but so far none of these are tumor specific. Polyclonal and monoclonal antibodies have been used for imaging of a wide variety of tumors with success. Radiolabeling of antibody is usually done with iodine isotopes of which 123 I is the best candidate for radioimmunodetection purposes. The labeling of antibodies through chelates makes it possible to use metal radioisotopes like 111 In, which is the best radioisotope for imaging with monoclonal antibodies due to its favorable half-life of 2.5 days. Usually imaging cannot be performed within 24 h after injection, but clearance of antibody can be increased by using F(ab) 2 of Fab. Another approach is to clear non-bound antibody by a second antibody, directed against the first. The detection limit of immunoimaging is about 2 cm, but will be improved by tomography or SPECT. There is still a high false positive and false negative rate, which makes it impossible to use radioimmunodetection as the only technique for diagnosis of tumors. In combination with other detection techniques, tumor imaging with monoclonal antibodies can improve diagnosis. 44 refs.; 3 tabs

  19. A murine monoclonal anti-idiotypic antibody detects a common idiotope on human, mouse and rabbit antibodies to allergen Lol p IV.

    Science.gov (United States)

    Zhou, E M; Dzuba-Fischer, J M; Rector, E S; Sehon, A H; Kisil, F T

    1991-09-01

    A syngeneic mouse monoclonal anti-idiotypic antibody (anti-Id), designated as B1/1, was generated against a monoclonal antibody (MoAb 91) specific for Ryegrass pollen allergen Lol p IV. This anti-Id recognized an idiotope (Id) that was also present on other monoclonal antibodies with the same specificity as MoAb 91. Observations that (i) the anti-Id inhibited the binding of MoAb 91 to Lol p IV and (ii) the Id-anti-Id interaction could be inhibited by Lol p IV indicated that the Id was located within or near the antigen combining site. These properties served to characterize B1/1 as an internal image anti-Id. Evidence that an immune response in different species to Lol p IV elicits the formation of antibodies which express a common Id was provided by the observations that (i) the Id-anti-Id interactions could be inhibited by mouse, human and rabbit antisera to Lol p IV and (ii) the binding of these antisera to Lol p IV could be inhibited by the anti-Id. Interestingly, the internal image anti-Id B1/1 also recognized an Id on a monoclonal antibody which was directed to an epitope of Lol p IV, different from that recognized by MoAb 91.

  20. Application of commercial enzyme linked immunosorbent assays (ELISA for the detection of antibodies for foot-and-mouth disease virus in wild boar and red deer

    Directory of Open Access Journals (Sweden)

    Terzić Svjetlana

    2012-01-01

    Full Text Available For detecting antibodies towards foot and mouth (FMD virus in sera collected from red deer hinds (Cervus elaphus and wild boars (Sus scrofa, three commercially available enzyme-linked immunosorbent assays (ELISA were used. Two ELISA kits (PrioCHECK FMDV NS and CHEKIT FMD-3ABC were used for the detection of antibodies towards non-structural proteins of FMD virus and one assay was based on the detection of antibodies for serotype O (PrioCHECK FMDV type O. All of the sera tested in our study were negative for antibodies against FMD virus. The aim of this study was to investigate the usefulness of commercially available ELISA kits given for marketing authorization in Croatia in testing the prevalence of FMD antibodies in wild boar and red deer populations. Since the producers of ELISA kits used in our study did not declare wild animals as a target species, we hypothesised that the same kits could be used for serological diagnosis of FMD in red deer and wild boars. Our study confirmed that the kits used are acceptable for detecting antibodies in both species tested, however, the investigation highlighted the problem of validating the kits due to the absence of available positive sera originating from red deer, as well as other susceptible species, especially artiodactyls.

  1. Human antibody and antigen response to IncA antibody of Chlamydia trachomatis.

    Science.gov (United States)

    Tsai, P Y; Hsu, M C; Huang, C T; Li, S Y

    2007-01-01

    The high prevalence of C. trachomatis worldwide has underscored the importance of identifying specific immunogenic antigens in facilitating diagnosis as well as vaccine development. The aim of this study is to evaluate IncA antibody and antigen production in natural human infections. Our temporal expression study showed that IncA transcription and protein expression could be detected as early as 4 hours after the start of infection. Antibody responses could be detected in urine and genital swab samples from C. trachomatis-positive patients. It is especially interesting to note that the IncA antigen could be detected in urine. In conclusion, we have identified IncA as an important antigen in human. The potential applicability of the IncA antibody or antigen in the diagnosis as well as to vaccine development for C. trachomatis is also discussed.

  2. Improvement of an enzyme immunosorbent assay for detecting antibodies against Dioctophyma renale.

    Science.gov (United States)

    Pedrassani, Daniela; do Nascimento, Adjair Antonio; André, Marcos Rogério; Machado, Rosangela Zacarias

    2015-09-15

    An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Plastic antibody based surface plasmon resonance nanosensors for selective atrazine detection

    Energy Technology Data Exchange (ETDEWEB)

    Yılmaz, Erkut [Department of Chemistry, Aksaray University, 68100 Aksaray (Turkey); Özgür, Erdoğan; Bereli, Nilay; Türkmen, Deniz [Department of Chemistry, Hacettepe University, 06800 Ankara (Turkey); Denizli, Adil, E-mail: denizli@hacettepe.edu.tr [Department of Chemistry, Hacettepe University, 06800 Ankara (Turkey)

    2017-04-01

    This study reports a surface plasmon resonance (SPR) based affinity sensor system with the use of molecular imprinted nanoparticles (plastic antibodies) to enhance the pesticide detection. Molecular imprinting based affinity sensor is prepared by the attachment of atrazine (chosen as model pesticide) imprinted nanoparticles onto the gold surface of SPR chip. Recognition element of the affinity sensor is polymerizable form of aspartic acid. The imprinted nanoparticles were characterized via FTIR and zeta-sizer measurements. SPR sensors are characterized with atomic force microscopy (AFM), scanning electron microscopy (SEM), Fourier transform infrared spectrophotometry (FTIR) and contact angle measurements. The imprinted nanoparticles showed more sensitivity to atrazine than the non-imprinted ones. Different concentrations of atrazine solutions are applied to SPR system to determine the adsorption kinetics. Langmuir adsorption model is found as the most suitable model for this affinity nanosensor system. In order to show the selectivity of the atrazine-imprinted nanoparticles, competitive adsorption of atrazine, simazine and amitrole is investigated. The results showed that the imprinted nanosensor has high selectivity and sensitivity for atrazine. - Highlights: • SPR based affinity sensor system was developed via molecular imprinting. • Recognition element of the affinity sensor is polymerizable form of an amino acid. • Combination of SPR and MIP offers highly selective sensor with long shelf-life. • Plastic antibody based biomimetic sensors offer relatively cheaper production. • Plastic antibody based biomimetic sensors offer high physical, chemical stability.

  4. Plastic antibody based surface plasmon resonance nanosensors for selective atrazine detection

    International Nuclear Information System (INIS)

    Yılmaz, Erkut; Özgür, Erdoğan; Bereli, Nilay; Türkmen, Deniz; Denizli, Adil

    2017-01-01

    This study reports a surface plasmon resonance (SPR) based affinity sensor system with the use of molecular imprinted nanoparticles (plastic antibodies) to enhance the pesticide detection. Molecular imprinting based affinity sensor is prepared by the attachment of atrazine (chosen as model pesticide) imprinted nanoparticles onto the gold surface of SPR chip. Recognition element of the affinity sensor is polymerizable form of aspartic acid. The imprinted nanoparticles were characterized via FTIR and zeta-sizer measurements. SPR sensors are characterized with atomic force microscopy (AFM), scanning electron microscopy (SEM), Fourier transform infrared spectrophotometry (FTIR) and contact angle measurements. The imprinted nanoparticles showed more sensitivity to atrazine than the non-imprinted ones. Different concentrations of atrazine solutions are applied to SPR system to determine the adsorption kinetics. Langmuir adsorption model is found as the most suitable model for this affinity nanosensor system. In order to show the selectivity of the atrazine-imprinted nanoparticles, competitive adsorption of atrazine, simazine and amitrole is investigated. The results showed that the imprinted nanosensor has high selectivity and sensitivity for atrazine. - Highlights: • SPR based affinity sensor system was developed via molecular imprinting. • Recognition element of the affinity sensor is polymerizable form of an amino acid. • Combination of SPR and MIP offers highly selective sensor with long shelf-life. • Plastic antibody based biomimetic sensors offer relatively cheaper production. • Plastic antibody based biomimetic sensors offer high physical, chemical stability.

  5. Evaluation of six immunoassays for detection of dengue virus-specific immunoglobulin M and G antibodies

    NARCIS (Netherlands)

    J. Groen (Jan); P. Koraka (Penelope); J. Velzing (Jans); C. Copra (Cederick); A.D.M.E. Osterhaus (Albert)

    2000-01-01

    textabstractThe performance of six commercially available immunoassay systems for the detection of dengue virus-specific immunoglobulin M (IgM) and IgG antibodies in serum was evaluated. These included two IgM and IgG enzyme immunoassays (EIA) from MRL Laboratories and PanBio, a rapid

  6. Development of a blocking ELISA for detection of serum neutralizing antibodies against newly emerged duck Tembusu virus.

    Directory of Open Access Journals (Sweden)

    Xuesong Li

    Full Text Available BACKGROUND: Since April 2010, domesticated ducks in China have been suffering from an emerging infectious disease characterized by retarded growth, high fever, loss of appetite, decline in egg production, and death. The causative agent was identified as a duck Tembusu virus (DTMUV, a member of the Ntaya virus (NTAV group within the genus Flavivirus, family Flaviviridae. DTMUV is highly contagious and spreads rapidly in many species of ducks. More than 10 million shelducks have been infected and approximately 1 million died in 2010. The disease remains a constant threat to the duck industry; however, it is not known whether DTMUV can infect humans or other mammalians, despite the fact that the virus has spread widely in southeast China, one of the most densely populated areas in the world. The lack of reliable methods to detect the serum antibodies against DTMUV has limited our ability to conduct epidemiological investigations in various natural hosts and to evaluate the efficiency of vaccines to DTMUV. METHODOLOGY/PRINCIPAL FINDINGS: A neutralizing monoclonal antibody (mAb 1F5 binding specifically to the E protein was developed. Based on the mAb, a blocking enzyme-linked immunosorbent assay (ELISA was developed for the detection of neutralizing antibodies against DTMUV. The average value of percent inhibition (PI of 350 duck serum samples obtained from DTMUV-free farms was 1.0% ± 5.8% (mean ± SD. The selected cut-off PI values for negative and positive sera were 12.6% (mean +2SD and 18.4% (mean +3SD, respectively. When compared with a serum neutralizing antibody test (SNT using chicken embryonated eggs, the rate of coincidence was 70.6% between the blocking ELISA and SNT, based on the titration of 20 duck DTMUV-positive serum samples. CONCLUSIONS/SIGNIFICANCE: The blocking ELISA based on a neutralizing mAb allowed rapid, sensitive, and specific detection of neutralization-related antibodies against DTMUV.

  7. Detection of Giardia duodenalis antigen in human fecal eluates by enzyme-linked immunosorbent assay using polyclonal antibodies

    Directory of Open Access Journals (Sweden)

    Sofía Duque-Beltrán

    2002-12-01

    Full Text Available The present study developed and standardized an enzime-linked immunosorbent assay (ELISA to detect Giardia antigen in feces using rabbit polyclonal antibodies. Giardia cysts were purified from human fecal samples by sucrose and percoll gradients. Gerbils (Meriones unguiculatus were infected to obtain trophozoites. Rabbits were inoculated with either cyst or trophozoite antigens of 14 Colombian Giardia isolates to develop antibodies against the respective stages. The IgG anti-Giardia were purified by sequential caprylic acid and ammonium sulfate precipitation. A portion of these polyclonal antibodies was linked to alkaline phosphatase (conjugate. One hundred and ninety six samples of human feces, from different patients, were tested by parasitologic diagnosis: 69 were positive for Giardia cysts, 56 had no Giardia parasites, and 71 revealed parasites other than Giardia. The optimal concentration of polyclonal antibodies for antigen capture was 40 µg/ml and the optimal conjugate dilution was 1:100. The absorbance cut-off value was 0.24. The parameters of the ELISA test for Giardia antigen detection were: sensitivity, 100% (95% CI: 93.4-100%; specificity, 95% (95% CI: 88.6-97.6%; positive predictive value, 91% (95% CI: 81.4-95.9%; and negative predictive value, 100% (95% CI: 96.1-100%. This ELISA will improve the diagnosis of Giardia infections in Colombia and will be useful in following patients after treatment.

  8. Specificity of anti-phospholipid antibodies in infectious mononucleosis: a role for anti-cofactor protein antibodies

    Science.gov (United States)

    Sorice, M; Pittoni, V; Griggi, T; Losardo, A; Leri, O; Magno, M S; Misasi, R; Valesini, G

    2000-01-01

    The antigen specificity of anti-phospholipid antibodies in infectious mononucleosis (IM) was studied using ELISA for the detection of anti-β2-glycoprotein I (β2-GPI), anti-annexin V, anti-protein S and anti-prothrombin antibodies and TLC immunostaining for the detection of anti-phospholipid antibodies. This technique enabled us to look at antibodies reacting to ‘pure’ phospholipid antigens in the absence of protein contamination. Sera from 46 patients with IM, 18 with systemic lupus erythematosus (SLE), 21 with primary anti-phospholipid antibody syndrome (PAPS), 50 with Helicobacter pylori infection and 30 healthy blood donors were tested. This study highlights anti-phospholipid antibodies in patients with IM as specific ‘pure’ anti-cardiolipin antibodies, while in PAPS and SLE patients anti-phosphatidylserine and anti-phosphatidylethanolamine antibodies were also found. This investigation also shows that the anti-cardiolipin antibodies found in IM can be present with anti-cofactor protein antibodies. The higher prevalence of anti-cofactor antibodies found in IM sera than in Helicobacter pylori sera may be due to the immunostimulatory effect and/or the polyclonal activation often observed in course of Epstein–Barr virus infection. However, anti-β2-GPI and, to a lesser extent, anti-prothrombin antibodies occur with a significantly lower prevalence in IM than in PAPS patients. This finding suggests that these antibodies should be regarded as the expression of the broad autoimmune syndrome involving the phospholipid-binding plasma proteins. PMID:10792380

  9. Method to conjugate polysaccharide antigens to surfaces for the detection of antibodies.

    Science.gov (United States)

    Boas, Ulrik; Lind, Peter; Riber, Ulla

    2014-11-15

    A new generic method for the conjugation of lipopolysaccharide (LPS)-derived polysaccharide antigens from gram-negative bacteria has been developed using Salmonella as a model. After removal of lipid A from the LPS by mild acidolysis, the polysaccharide antigen was conjugated to polystyrene microbeads modified with N-alkyl hydroxylamine and N-alkyl-O-methyl hydroxylamine surface groups by incubation of antigen and beads for 16 h at 40 °C without the need for coupling agents. The efficiency of the new method was evaluated by flow cytometry in model samples and serum samples containing antibodies against Salmonella typhimurium and Salmonella dublin. The presented method was compared with a similar method for conjugation of Salmonella polysaccharide antigens to surfaces. Here, the new method showed higher antigen coupling efficiency by detecting low concentrations of antibodies. Furthermore, the polysaccharide-conjugated beads showed preserved bioactivity after 1 year of use. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Accurate antemortem diagnosis of equine protozoal myeloencephalitis (EPM) based on detecting intrathecal antibodies against Sarcocystis neurona using the SnSAG2 and SnSAG4/3 ELISAs.

    Science.gov (United States)

    Reed, S M; Howe, D K; Morrow, J K; Graves, A; Yeargan, M R; Johnson, A L; MacKay, R J; Furr, M; Saville, W J A; Williams, N M

    2013-01-01

    Recent work demonstrated the value of antigen-specific antibody indices (AI and C-value) to detect intrathecal antibody production against Sarcocystis neurona for antemortem diagnosis of equine protozoal myeloencephalitis (EPM). The study was conducted to assess whether the antigen-specific antibody indices can be reduced to a simple serum : cerebrospinal fluid (CSF) titer ratio to achieve accurate EPM diagnosis. Paired serum and CSF samples from 128 horses diagnosed by postmortem examination. The sample set included 44 EPM cases, 35 cervical-vertebral malformation (CVM) cases, 39 neurologic cases other than EPM or CVM, and 10 non-neurologic cases. Antibodies against S. neurona were measured in serum and CSF pairs using the SnSAG2 and SnSAG4/3 (SnSAG2, 4/3) ELISAs, and the ratio of each respective serum titer to CSF titer was determined. Likelihood ratios and diagnostic sensitivity and specificity were calculated based on serum titers, CSF titers, and serum : CSF titer ratios. Excellent diagnostic sensitivity and specificity was obtained from the SnSAG2, 4/3 serum : CSF titer ratio. Sensitivity and specificity of 93.2 and 81.1%, respectively, were achieved using a ratio cutoff of ≤100, whereas sensitivity and specificity were 86.4 and 95.9%, respectively, if a more rigorous cutoff of ≤50 was used. Antibody titers in CSF also provided good diagnostic accuracy. Serum antibody titers alone yielded much lower sensitivity and specificity. The study confirms the value of detecting intrathecal antibody production for antemortem diagnosis of EPM, and they further show that the antigen-specific antibody indices can be reduced in practice to a simple serum : CSF titer ratio. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  11. Comparison of indirect hemagglutination and 51Chromium release tests for detection of herpes simplex virus types 1 and 2 antibodies in patients with recurrent herpes infections

    International Nuclear Information System (INIS)

    Kesavalu, L.; Seth, P.

    1980-01-01

    Indirect hemagglutination and 51 Cr release tests (IHAT and 51-CRT respectively) were compared in patients with recurrent herpes simplex virus (HSV) infections from whom HSV-1 or HSV-2 was isolated. Both tests were equally sensitive and specific in detecting HSV antibodies. However, IHAT was more specific in detecting homologous HSV antibody response in patients with recurrent HSV-2 infections. Past infections with HSV-1 in the patients with dual infections were detected by determining HSV-type specific antibodies by inhibition of IHAT. Cross absorption studies showed that the antibody reactivity measured by the two tests was qualitatively and quantitatively different. Nevertheless, IHAT has been found to be more appropriate test for seroepidemiologic studies of HSV-2 infections because of its specificity, rapidity and less cost, whereas, 51-CRT appears to measure antibodies against recent and more predominant type of infecting HSV. (Author)

  12. Direct Detection of Protein Biomarkers in Human Fluids Using Site-Specific Antibody Immobilization Strategies

    Directory of Open Access Journals (Sweden)

    Maria Soler

    2014-01-01

    Full Text Available Design of an optimal surface biofunctionalization still remains an important challenge for the application of biosensors in clinical practice and therapeutic follow-up. Optical biosensors offer real-time monitoring and highly sensitive label-free analysis, along with great potential to be transferred to portable devices. When applied in direct immunoassays, their analytical features depend strongly on the antibody immobilization strategy. A strategy for correct immobilization of antibodies based on the use of ProLinker™ has been evaluated and optimized in terms of sensitivity, selectivity, stability and reproducibility. Special effort has been focused on avoiding antibody manipulation, preventing nonspecific adsorption and obtaining a robust biosurface with regeneration capabilities. ProLinker™-based approach has demonstrated to fulfill those crucial requirements and, in combination with PEG-derivative compounds, has shown encouraging results for direct detection in biological fluids, such as pure urine or diluted serum. Furthermore, we have implemented the ProLinker™ strategy to a novel nanoplasmonic-based biosensor resulting in promising advantages for its application in clinical and biomedical diagnosis.

  13. Direct detection of protein biomarkers in human fluids using site-specific antibody immobilization strategies.

    Science.gov (United States)

    Soler, Maria; Estevez, M-Carmen; Alvarez, Mar; Otte, Marinus A; Sepulveda, Borja; Lechuga, Laura M

    2014-01-29

    Design of an optimal surface biofunctionalization still remains an important challenge for the application of biosensors in clinical practice and therapeutic follow-up. Optical biosensors offer real-time monitoring and highly sensitive label-free analysis, along with great potential to be transferred to portable devices. When applied in direct immunoassays, their analytical features depend strongly on the antibody immobilization strategy. A strategy for correct immobilization of antibodies based on the use of ProLinker™ has been evaluated and optimized in terms of sensitivity, selectivity, stability and reproducibility. Special effort has been focused on avoiding antibody manipulation, preventing nonspecific adsorption and obtaining a robust biosurface with regeneration capabilities. ProLinker™-based approach has demonstrated to fulfill those crucial requirements and, in combination with PEG-derivative compounds, has shown encouraging results for direct detection in biological fluids, such as pure urine or diluted serum. Furthermore, we have implemented the ProLinker™ strategy to a novel nanoplasmonic-based biosensor resulting in promising advantages for its application in clinical and biomedical diagnosis.

  14. Human monoclonal antibody {sup 99m}Tc-88BV59: detection of colorectal cancer, recurrent or metastatic disease and immunogenicity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Krause, B.J. [Department of Nuclear Medicine, Johann Wolfgang Goethe University Medical Center, Frankfurt/Main (Germany); Baum, R.P. [Department of Nuclear Medicine, Johann Wolfgang Goethe University Medical Center, Frankfurt/Main (Germany); Staib-Sebler, E. [Department of General and Abdominal Surgery, Johann Wolfgang Goethe University Medical Center, Frankfurt/Main (Germany); Lorenz, M. [Department of General and Abdominal Surgery, Johann Wolfgang Goethe University Medical Center, Frankfurt/Main (Germany); Niesen, A. [Department of Nuclear Medicine, Johann Wolfgang Goethe University Medical Center, Frankfurt/Main (Germany); Hoer, G. [Department of Nuclear Medicine, Johann Wolfgang Goethe University Medical Center, Frankfurt/Main (Germany)

    1997-01-01

    This study presents immunoscintigraphic results in 24 patients suffering from primary colorectal cancer, recurrent or metastatic disease after the injection of 1197-1351 MBq technetium-99m labelled totally human monoclonal antibody 88BV59. Labelling efficacy of {sup 99m}Tc-88BV59 ranged from 97% to 99%. Immunoscintigraphy was performed 18-20 h after injection. Scintigraphic findings were compared with those of computed tomography (CT). Patients underwent surgery in order to evaluate immunoscintigraphic findings histologically. Sera of the patients (before injection and 1 and 3 months post infusion) were analysed for the presence of human anti-human antibodies (HAHA). None of the patients showed a HAHA response as assessed by a solid-phase ELISA assay. The antibody scan detected about 25% more lesions than CT. In the detection of extrahepatic disease, the sensitivity of the antibody scan proved to be 68%, whereas the sensitivity of CT was 41%. (orig.). With 3 figs., 1 tab.

  15. Development and application of radioimmunoassay and enzyme immunoassays in microbiological and immunological diagnosis. 3. Comparative studies for the detection of virus antibodies with passive hemagglutination test, radioimmunoassay and enzyme immunoassay, resp

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, H; Struy, H; Morenz, J [Medizinische Akademie, Magdeburg (German Democratic Republic)

    1982-06-01

    Radioimmuno- and enzyme immunoassays (solid phase RIA and ELISA) developed by the authors for the determination of antibodies of adeno-2- and parainfluenza-1-viruses are described and the detection sensibility for antibodies is compared with that of the conventional passive hemagglutination test. The sensibility of the radioimmunoassay for the detection of IgG antibodies against adeno-2-viruses is nearly 10 times higher than that of the passive hemagglutination. RIA and ELISA show no essential differences in their detection sensibilities in the detection of IgG antibodies against parainfluenza-1-viruses.

  16. Express immunochromatographic detection of antibodies against Brucella abortus in cattle sera based on quantitative photometric registration and modulated cut-off level.

    Science.gov (United States)

    Sotnikov, Dmitriy V; Byzova, Nadezhda A; Zherdev, Anatoly V; Eskendirova, Saule Z; Baltin, Kairat K; Mukanov, Kasim K; Ramankulov, Erlan M; Sadykhov, Elchin G; Dzantiev, Boris B

    2015-01-01

    An immunochromatographic test system was developed for rapid detection of the levels of specific IgG antibodies to Brucella abortus lipopolysaccharide, as a tool for diagnosis of brucellosis in cattle. The pilot test strips were examined using blood sera from sick (78 samples) and healthy (35 samples) cows. The results obtained by immunochromatographic assay, using a portable optical densitometer for digital video detection, correlate well with the results obtained by immunoenzyme assay and are in agreement with the results of the disease diagnosis. The new test system allows detection of antibodies within 10 min and can be proposed as an alternative to the methods available for serodiagnosis of brucellosis.

  17. Comparison of 5 Ki-67 antibodies regarding reproducibility and capacity to predict prognosis in breast cancer: does the antibody matter?

    Science.gov (United States)

    Ács, Balázs; Kulka, Janina; Kovács, Kristóf Attila; Teleki, Ivett; Tőkés, Anna-Mária; Meczker, Ágnes; Győrffy, Balázs; Madaras, Lilla; Krenács, Tibor; Szász, Attila Marcell

    2017-07-01

    Although several antibodies are available for immunohistochemical detection of Ki-67, even the most commonly used MIB-1 has not been validated yet. Our aim was to compare 5 commercially available antibodies for detection of Ki-67 in terms of agreement and their ability in predicting prognosis of breast cancer. Tissue microarrays were constructed from 378 breast cancer patients' representative formalin-fixed, paraffin-embedded tumor blocks. Five antibodies were used to detect Ki-67 expression: MIB-1 using chromogenic detection and immunofluorescent-labeled MIB-1, SP-6, 30-9, poly, and B56. Semiquantitative assessment was performed by 2 pathologists independently on digitized slides. To compare the 5 antibodies, intraclass correlation and concordance correlation coefficient were used. All the antibodies but immunofluorescent-labeled MIB-1 (at 20% and 30% thresholds, P=.993 and P=.342, respectively) and B56 (at 30% threshold, P=.288) separated high- and low-risk patient groups. However, there were a significant difference (P values for all comparisons≤.005) and a moderate concordance (intraclass correlation, 0.645) between their Ki-67 labeling index scores. The highest concordance was found between MIB-1 and poly (concordance correlation coefficient=0.785) antibodies. None of the antibodies except Ki-67 labeling index as detected by poly (P=.031) at 20% threshold and lymph node status (Pantibodies in their capacity to detect proliferating tumor cells and to separate low- and high-risk breast cancer patient groups. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Evaluation of classical swine fever virus antibody detection assays with an emphasis on the differentiation of infected from vaccinated animals

    DEFF Research Database (Denmark)

    Schroeder, S.; von Rosen, Tanya; Blome, S.

    2012-01-01

    vaccinated animals (DIVA). The Chekit* CSF-Sero and the HerdChek* CSFV Ab, both of which detect antibodies against the E2 protein of classical swine fever virus (CSFV), had the highest sensitivity. Both tests were practicable and showed good reproducibility. Comparable sensitivity was shown by the Chekit......The aim of this study was to evaluate the general characteristics of commercially available enzyme-linked immunosorbent assays (ELISAs) to detect antibody against classical swine fever (CSF), as well as to assess their potential use as accompanying marker tests able to differentiate infected from......* CSF-Marker, an Erns ELISA. However, this test does not allow differentiation between antibodies directed against ruminant pestiviruses and those against CSFV. Therefore, it is not suitable for use with the chimeric marker vaccines tested. The PrioCHECK® CSFV Erns was the only ELISA suitable for use...

  19. Clinical significance of detection of antibodies to fetal and adult acetylcholine receptors in myasthenia gravis

    Institute of Scientific and Technical Information of China (English)

    Qi-Guang Shi; Zhi-Hong Wang; Xiao-Wei Ma; Da-Qi Zhang; Chun-Sheng Yang; Fu-Dong Shi; Li Yang

    2012-01-01

    Objective To evaluate the frequency,distribution and clinical significance of the antibodies to the fetal and/or adult acetylcholine receptor (AChR) in patients with myasthenia gravis (MG).Methods AChR antibodies were detected by cell-based assay in the serum of ocular MG (OMG) (n =90) and generalized MG (GMG) patients (n =110).The fetaltype (2α∶ β∶ γ∶ δ) and adult-type (2α∶ β∶ ε∶ δ) AChR were used as antigens,and their relevance to disease presentation was assessed.Results The overall frequencies of anti-adult and anti-fetal AChR antibodies were similar in all 200 patients examined,with 14 having serum specific to the AChR-γ subunit,and 22 to the AChR-ε subunit.The overall sensitivity when using the fetal and adult AChR antibodies was higher than that when using the fetal AChR antibody only (P =0.015).Compared with OMG patients,the mean age at disease onset and the positive ratio of antibodies to both isoforms of the AChR were significantly higher in patients who subsequently progressed to GMG.Older patients and patients with both anti-fetal and anti-adult AChR antibodies had a greater risk for developing generalized disease [odds ratio (OR),1.03;95% confidence interval (CI),1.01-1.06 and OR,5.09;95% CI,2.23-11.62].Conclusion Using both fetal-and adulttype AChRs as the antigens may be more sensitive than using either subtype.Patients with serum specific to both isoforms are at a greater risk of progressing to GMG.Patients with disease onset at an advanced age appear to have a higher frequency of GMG conversion.

  20. Use of monoclonal antibodies against Hendra and Nipah viruses in an antigen capture ELISA

    Directory of Open Access Journals (Sweden)

    Spiropoulou Christina F

    2010-06-01

    Full Text Available Abstract Background Outbreaks of Hendra (HeV and Nipah (NiV viruses have been reported starting in 1994 and 1998, respectively. Both viruses are capable of causing fatal disease in humans and effecting great economical loss in the livestock industry. Results Through screening of hybridomas derived from mice immunized with γ-irradiated Nipah virus, we identified two secreted antibodies; one reactive with the nucleocapsid (N protein and the other, the phosphoprotein (P of henipaviruses. Epitope mapping and protein sequence alignments between NiV and HeV suggest the last 14 amino acids of the carboxyl terminus of the N protein is the target of the anti-N antibody. The anti-P antibody recognizes an epitope in the amino-terminal half of P protein. These monoclonal antibodies were used to develop two antigen capture ELISAs, one for virus detection and the other for differentiation between NiV and HeV. The lower limit of detection of the capture assay with both monoclonal antibodies was 400 pfu. The anti-N antibody was used to successfully detect NiV in a lung tissue suspension from an infected pig. Conclusion The antigen capture ELISA developed is potentially affordable tool to provide rapid detection and differentiation between the henipaviruses.

  1. A new trivalent SnSAG surface antigen chimera for efficient detection of antibodies against Sarcocystis neurona and diagnosis of equine protozoal myeloencephalitis.

    Science.gov (United States)

    Yeargan, Michelle; de Assis Rocha, Izabela; Morrow, Jennifer; Graves, Amy; Reed, Stephen M; Howe, Daniel K

    2015-05-01

    Enzyme-linked immunosorbent assays (ELISAs) based on the SnSAG surface antigens of Sarcocystis neurona provide reliable detection of infection by the parasite. Moreover, accurate serodiagnosis of equine protozoal myeloencephalitis (EPM) is achieved with the SnSAG ELISAs by measuring antibodies in serum and cerebrospinal fluid (CSF) to reveal active infection in the central nervous system. Two independent ELISAs based on recombinant (r)SnSAG2 or a chimeric fusion of SnSAG3 and SnSAG4 (rSnSAG4/3) are currently used together for EPM serodiagnosis to overcome varied antibody responses in different horses. To achieve reliable antibody detection with a single ELISA instead of 2 separate ELISAs, rSnSAG2 was fused with rSnSAG4/3 into a single trivalent protein, designated rSnSAG2/4/3. Paired serum and CSF from 163 horses were tested with all 3 ELISAs. When the consensus antibody titers obtained with the rSnSAG2 and rSnSAG4/3 ELISAs were compared to the single SAG2/4/3 ELISA titers, Spearman rank correlation coefficients of ρ = 0.74 and ρ = 0.90 were obtained for serum and CSF, respectively, indicating strong agreement between the tests. When the rSnSAG2 and rSnSAG4/3 consensus serum-to-CSF titer ratio was compared to the rSnSAG2/4/3 serum-to-CSF titer ratio, the Spearman correlation coefficient was ρ = 0.87, again signifying strong agreement. Importantly, comparing the diagnostic interpretation of the serum-to-CSF titer ratios yielded a Cohen kappa value of 0.77. These findings suggest that the single ELISA based on the trivalent rSnSAG2/4/3 will provide serologic and diagnostic results that are highly comparable to the consensus of the 2 independent ELISAs based on rSnSAG2 and rSnSAG4/3. © 2015 The Author(s).

  2. An evaluation of saliva as an alternative to plasma for the detection of hepatitis C virus antibodies

    Directory of Open Access Journals (Sweden)

    Moorthy M

    2008-01-01

    Full Text Available Purpose: Seroepidemiological studies on the prevalence of Hepatitis C virus (HCV in India have been hampered by reluctance of subjects to provide blood samples for testing. We evaluated the use of saliva as an alternate specimen to blood for the detection of antibodies to HCV. Methods: Chronic liver disease (CLD patients attending the liver clinic were recruited for this study. A saliva and plasma sample (sample pair was collected from each patient included in the study. Saliva samples were collected using a commercially available collection device - OmniSal. Sample pairs were tested with an in-use ELISA for the detection of antibodies to HCV (HCV-Ab, with a minor modification in the manufacturer′s protocol while testing saliva. The cut-off absorbance value for declaring a sample as positive was determined by receiver operating curve (ROC analysis. HCV-Ab positivity in saliva was compared with that in plasma as well as with viral load in plasma and infecting genotype of the virus. Sensitivity, specificity, positive and negative predictive values, and correlation coefficients were calculated using Medcalc statistical software. Results: The optimal accuracy indices were: sensitivity-81.6%; specificity-92.5%; PPV-85.1% and NPV-90.5%. No correlation was found between salivary positivity and HCV viral load in plasma or infecting genotype. Conclusions: The accuracy indices indicate that the assay must be optimized further before it can be recommended for routine use in epidemiological surveys for HCV-Ab.

  3. [In vitro immunization for the production of antibodies to tetanus toxin and toxoid. 1. Systems for the detection of in vitro synthetized specific immunoglobulins. Strategies of test development].

    Science.gov (United States)

    Kiessig, S T; Jahn, S; Porstmann, T; von Baehr, R

    1987-01-01

    By means of semipurified tetanus toxin for solid phase coating in an enzyme immunoassay (ELISA) for detection of specific IgG and IgM antibodies a detection limit of 0.02 IU per litre was achieved. The addition of serum from animals like horses or goats as inert protein to the dilution medium was omitted to prevent a displacement of human antibodies by antitetanus antibodies present in the animals sera. The specificity of the ELISA was demonstrated by inhibition experiments with soluble antigen and in an ELISA for detection of anti-tetanus toxin antibodies from mice immunized with the toxoid from the different purification steps.

  4. Performance Assessment of Four Chimeric Trypanosoma cruzi Antigens Based on Antigen-Antibody Detection for Diagnosis of Chronic Chagas Disease.

    Directory of Open Access Journals (Sweden)

    Fred Luciano Neves Santos

    Full Text Available The performance of serologic tests in chronic Chagas disease diagnosis largely depends on the type and quality of the antigen preparations that are used for detection of anti-Trypanosoma cruzi antibodies. Whole-cell T. cruzi extracts or recombinant proteins have shown variation in the performance and cross-reactivity. Synthetic chimeric proteins comprising fragments of repetitive amino acids of several different proteins have been shown to improve assay performances to detect Chagasic infections. Here, we describe the production of four chimeric T. cruzi proteins and the assessment of their performance for diagnostic purposes. Circular Dichroism spectra indicated the absence of well-defined secondary structures, while polydispersity evaluated by Dynamic Light Scattering revealed only minor aggregates in 50 mM carbonate-bicarbonate (pH 9.6, demonstrating that it is an appropriate buffering system for sensitizing microplates. Serum samples from T. cruzi-infected and non-infected individuals were used to assess the performance of these antigens for detecting antibodies against T. cruzi, using both enzyme-linked immunosorbent assay and a liquid bead array platform. Performance parameters (AUC, sensitivity, specificity, accuracy and J index showed high diagnostic accuracy for all chimeric proteins for detection of specific anti-T. cruzi antibodies and differentiated seropositive individuals from those who were seronegative. Our data suggest that these four chimeric proteins are eligible for phase II studies.

  5. Monoclonal antibody against Porphyromonas (Bacteroides) endodontalis lipopolysaccharide and application of the antibody for direct identification of the species.

    Science.gov (United States)

    Hanazawa, S; Sagiya, T; Kitami, H; Ohta, K; Nishikawa, H; Kitano, S

    1991-01-01

    The aim of the present study was to develop a monoclonal antibody that recognizes the shared antigen of Porphyromonas endodontalis so that we could use the antibody in direct identification and detection of P. endodontalis in infectious material from apical periodontal patients. We established a hybridoma cell line producing monoclonal antibody (BEB5) specific for P. endodontalis. BEB5 antibody reacted with all of the P. endodontalis strains tested, but not with any of the other black-pigmented Porphyromonas and Bacteroides spp. The antibody reacted specifically with the lipopolysaccharide (LPS) of three P. endodontalis strains of different serotypes (O1K1, O1K2, and O1K-). Western blotting (immunoblotting) analysis confirmed the specificity of the antibody to these LPSs, because the antibody recognized the typical "repetitive ladder" pattern characteristic of LPS on sodium dodecyl sulfate-polyacrylamide electrophoretic gels. These observations demonstrate that P. endodontalis LPS is the shared antigen of this species. The antibody can specifically identify P. endodontalis on nitrocellulose membrane blots of bacterial colonies grown on agar. The antibody is also capable of directly detecting the presence of P. endodontalis in infectious material by immunoslot blot assay. These results indicate that LPS is the shared antigen of P. endodontalis and that BEB5 antibody against LPS is a useful one for direct identification and detection of the organisms in samples from apical periodontal patients. Images PMID:1774262

  6. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    Science.gov (United States)

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  7. E4 antibodies facilitate detection and type-assignment of active HPV infection in cervical disease.

    Directory of Open Access Journals (Sweden)

    Heather Griffin

    Full Text Available High-risk human papillomavirus (HPV infections are the cause of nearly all cases of cervical cancer. Although the detection of HPV DNA has proved useful in cervical diagnosis, it does not necessarily predict disease presence or severity, and cannot conclusively identify the causative type when multiple HPVs are present. Such limitations may be addressed using complementary approaches such as cytology, laser capture microscopy, and/or the use of infection biomarkers. One such infection biomarker is the HPV E4 protein, which is expressed at high level in cells that are supporting (or have supported viral genome amplification. Its distribution in lesions has suggested a role in disease staging. Here we have examined whether type-specific E4 antibodies may also allow the identification and/or confirmation of causal HPV-type. To do this, type-specific polyclonal and monoclonal antibodies against three E4 proteins (HPV-16, -18, and -58 were generated and validated by ELISA and western blotting, and by immunohistochemistry (IHC staining of epithelial rafts containing these individual HPV types. Type-specific detection of HPV and its associated disease was subsequently examined using formalin-fixed paraffin-embedded cervical intra-epithelial neoplasias (CIN, (n = 247 and normal controls (n = 28. All koilocytotic CIN1 lesions showed type-specific E4 expression of their respective HPV types. Differences were noted amongst E4 expression patterns in CIN3. HPV-18 E4 was not detected in any of the 6 HPV-18 DNA-positive CIN3 lesions examined, whereas in HPV-16 and -58 CIN3, 28/37 (76% and 5/9 (55.6% expressed E4 respectively, usually in regions of epithelial differentiation. Our results demonstrate that type-specific E4 antibodies can be used to help establish causality, as may be required when multiple HPV types are detected. The unique characteristics of the E4 biomarker suggest a role in diagnosis and patient management particularly when used in combination.

  8. Design of indirect solid-phase immunosorbent methods for detecting arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A

    1984-05-01

    Specifications have been elaborated for formulating indirect solid-phase enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (SPRIA) methods that employ anti-human and anti-mice G class immunoglobulin (IgG), conjugated with horseradish peroxidase and /sup 125/I for detecting the arenaviruses Junin, Machupo, Tacaribe, Amalpari, Tamiami, Lassa, and LCM (lymphocytic choriomeningitis). These methods make it possible to identify with a high degree of sensitivity arenavirus antigens and antibodies in various kinds of material.

  9. Simplifying sampling for African swine fever surveillance: Assessment of antibody and pathogen detection from blood swabs.

    Science.gov (United States)

    Carlson, J; Zani, L; Schwaiger, T; Nurmoja, I; Viltrop, A; Vilem, A; Beer, M; Blome, S

    2018-02-01

    African swine fever (ASF) is a notifiable disease with serious socio-economic consequences that has been present in wild boar in the Baltic States and Poland since 2014. An introduction of ASF is usually accompanied by increased mortality, making fallen wild boar and hunted animals with signs of disease the main target for early warning and passive surveillance. It is difficult, however, to encourage hunters and foresters to report and take samples from these cases. A pragmatic and easy sampling approach with quick-drying swabs could facilitate this. In this study, we further evaluated the use of dry blood swabs for the detection of ASFV antibody and genome with samples from animal trials and diagnostic submissions (blood, bone and organs) from Estonia. Compared to serum samples, dried blood swabs yielded 93.1% (95% confidence interval: [83.3, 98.1]) sensitivity and 100% [95.9, 100.0] specificity in a commercial ASFV antibody ELISA. Similarly, the swabs gave a sensitivity of 98.9% [93.4, 100.0] and a specificity of 98.1% [90.1, 100.0] for genome detection by a standard ASFV p72 qPCR when compared to EDTA blood. The same swabs were tested in a VP72-antibody lateral flow device, with a sensitivity of 94.7% [85.4, 98.9] and specificity of 96.1% [89.0, 99.2] compared to the serum ELISA. When GenoTube samples tested in ELISA and LFD were compared, the sensitivity was 96.3% [87.3, 99.5] and the specificity was 93.8% [86.0, 97.9]. This study demonstrates reliable detection of ASFV antibody and genome from swabs. A field test of the swabs with decomposed wild boar carcasses in an endemic area in Estonia also gave promising results. Thus, this technique is a practical approach for surveillance of ASF in both free and endemic areas. © 2017 Blackwell Verlag GmbH.

  10. Radioimmunoassay of serum antibodies with B-streptococcus specificity in pregnant women and infants

    International Nuclear Information System (INIS)

    Frey, C.W.

    1980-01-01

    In a specific competitive radioimmunoassay of purified rabbit antibodies, labeled with iodine 125 against group- and type-antigens of streptococcus agalactiae (streptococci type B), we investigated the amount of serum anti-bodies providing specificity of streptococci type B in not preselected pregnant women, newborn and babies with colonies of streptococci type B or with diseases due to streptococci type B and in some of their mothers. These antibodies could be detected in 26 of 45 pregnant women and in 3 of 7 children with colonies of streptococci type B. 5 of 18 newborn with the ''early-onset'' type of infection and 6 of 7 of their mothers provided antibodies with specificity of streptococci type B as did one of two newborn with the ''late onset'' type of infection. Contrary to the supposition of Baker and Kasper and in accordance with the findings of Wilkinson, the ''risk group'' cannot be determined only by detecting the antibodies against streptococci type B. The risk group comprises those persons in whom the colonisation of streptococci agalactiae leads to the frequently life-threatening infecton of neonatals with streptococci type B. (orig.) [de

  11. Radioiodination of antibodies for tumor imaging

    International Nuclear Information System (INIS)

    Saha, G.B.

    1983-01-01

    In view of the great potential of radioiodinated antibody for the detection and treatment of cancer, the present article deals with the various techniques of radioiodination of antibody and their uses. Topics include methods of iodination of antibody, advantages and disadvantages of different methods, and effects of radioiodination on the antibody molecules with respect to their physiochemical and immunologic reactivity. In addition, the clinical usefulness of radioiodinated antibodies is discussed. (Auth.)

  12. Rapid detection of serum antibody by dual-path platform VetTB assay in white-tailed deer infected with Mycobacterium bovis.

    Science.gov (United States)

    Lyashchenko, Konstantin P; Greenwald, Rena; Esfandiari, Javan; O'Brien, Daniel J; Schmitt, Stephen M; Palmer, Mitchell V; Waters, W Ray

    2013-06-01

    Bovine tuberculosis (TB) in cervids remains a significant problem affecting farmed herds and wild populations. Traditional skin testing has serious limitations in certain species, whereas emerging serological assays showed promising diagnostic performance. The recently developed immunochromatographic dual-path platform (DPP) VetTB assay has two antigen bands, T1 (MPB83 protein) and T2 (CFP10/ESAT-6 fusion protein), for antibody detection. We evaluated the diagnostic accuracy of this test by using serum samples collected from groups of white-tailed deer experimentally inoculated with Mycobacterium bovis, M. avium subsp. paratuberculosis, or M. bovis BCG Pasteur. In addition, we used serum samples from farmed white-tailed deer in herds with no history of TB, as well as from free-ranging white-tailed deer culled during field surveillance studies performed in Michigan known to have bovine TB in the wild deer population. The DPP VetTB assay detected antibody responses in 58.1% of experimentally infected animals within 8 to 16 weeks postinoculation and in 71.9% of naturally infected deer, resulting in an estimated test sensitivity of 65.1% and a specificity of 97.8%. The higher seroreactivity found in deer with naturally acquired M. bovis infection was associated with an increased frequency of antibody responses to the ESAT-6 and CFP10 proteins, resulting in a greater contribution of these antigens, in addition to MPB83, to the detection of seropositive animals, compared with experimental M. bovis infection. Deer experimentally inoculated with either M. avium subsp. paratuberculosis or M. bovis BCG Pasteur did not produce cross-reactive antibodies that could be detected by the DPP VetTB assay. The present findings demonstrate the relatively high diagnostic accuracy of the DPP VetTB test for white-tailed deer, especially in the detection of naturally infected animals.

  13. Routinely used immunoassays do not detect circulating anti-GBM antibodies against native NC1 hexamer and EA epitope of the α3 chain of type IV collagen.

    Science.gov (United States)

    Clavarino, Giovanna; Gauthier, Arnaud; Hellmark, Thomas; Carron, Pierre-Louis; Giovannini, Diane; Colliard, Sophie; Dragon-Durey, Marie-Agnès; Segelmark, Mårten; Cesbron, Jean-Yves; Dumestre-Pérard, Chantal

    2018-04-12

    Detection of circulating anti-GBM antibodies has a key role for the diagnosis of Goodpasture syndrome but immunoassays using purified or recombinant alpha3(IV)NC1 as antigen do not recognize all anti-GBM antibodies. We show that anti-GBM antibodies directed against epitopes in their native conformation or cryptic epitopes are detected by indirect immunofluorescence. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    OpenAIRE

    Alderete, J F

    1984-01-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses durin...

  15. Developments of sensitive immunoassays for detection of antibodies against hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Ionescu-Matiu, I; Sanchez, Y; Dreesman, G R [Baylor Univ., Houston, TX (USA). Coll. of Medicine; Fields, H A [Centers for Disease Control, Public Health Service, Department of Health and Human Services, Phoenix, AZ (USA)

    1983-01-01

    Three micro solid phase immunoassays (a micro-SPRIA and two ELISA techniques) were developed and tested for the detection of anti-HBs antibodies. Two different crosslinkers (glutaraldehyde and N-succinimidyl 3-(2-pyridyldithio) propionate) were used to couple a goat anti-mouse IgG reagent to alkaline phosphatase for use as enzyme-labeled probes in the two ELISA tests. With the latter cross-linker, a defined conjugate with a 1 : 1 antibody-enzyme molar ratio was obtained. The sensitivities of micro-SPRIA and the two types of ELISA were compared to that of the commercial solid phase radioimmunoassay AUSAB test. All three microtests were significantly more sensitive than the AUSAB test. The ELISA using the glutaraldehyde cross-linked conjugate was 3-5 times less sensitive than micro-SPRIA, while the ELISA using the disulfide-linked conjugate was 2.6-4.0 times more sensitive than micro-SPRIA.

  16. Direct, Specific and Rapid Detection of Staphylococcal Proteins and Exotoxins Using a Multiplex Antibody Microarray.

    Directory of Open Access Journals (Sweden)

    Bettina Stieber

    Full Text Available S. aureus is a pathogen in humans and animals that harbors a wide variety of virulence factors and resistance genes. This bacterium can cause a wide range of mild to life-threatening diseases. In the latter case, fast diagnostic procedures are important. In routine diagnostic laboratories, several genotypic and phenotypic methods are available to identify S. aureus strains and determine their resistances. However, there is a demand for multiplex routine diagnostic tests to directly detect staphylococcal toxins and proteins.In this study, an antibody microarray based assay was established and validated for the rapid detection of staphylococcal markers and exotoxins. The following targets were included: staphylococcal protein A, penicillin binding protein 2a, alpha- and beta-hemolysins, Panton Valentine leukocidin, toxic shock syndrome toxin, enterotoxins A and B as well as staphylokinase. All were detected simultaneously within a single experiment, starting from a clonal culture on standard media. The detection of bound proteins was performed using a new fluorescence reading device for microarrays.110 reference strains and clinical isolates were analyzed using this assay, with a DNA microarray for genotypic characterization performed in parallel. The results showed a general high concordance of genotypic and phenotypic data. However, genotypic analysis found the hla gene present in all S. aureus isolates but its expression under given conditions depended on the clonal complex affiliation of the actual isolate.The multiplex antibody assay described herein allowed a rapid and reliable detection of clinically relevant staphylococcal toxins as well as resistance- and species-specific markers.

  17. Limited diagnostic capacities of two commercial assays for the detection of Leptospira immunoglobulin M antibodies in Laos

    NARCIS (Netherlands)

    Blacksell, Stuart D.; Smythe, Lee; Phetsouvanh, Rattanaphone; Dohnt, Michael; Hartskeerl, Rudy; SymondS, Meegan; Slack, Andrew; Vongsouvath, Manivanh; Davong, Viengmone; Lattana, Olay; Phongmany, Simmaly; Keolouangkot, Valy; White, Nicholas J.; Day, Nicholas P. J.; Newton, Paul N.

    2006-01-01

    The diagnostic utility of immunochromatographic (Leptotek) and enzyme-linked immunosorbent assay (ELISA; Panbio) tests for the detection of Leptospira immunoglobulin M antibodies was assessed in febrile adults admitted in Vientiane, Laos. Both tests demonstrated poor diagnostic accuracy using

  18. Detection of Francisella tularensis-Specific Antibodies in Patients with Tularemia by a Novel Competitive Enzyme-Linked Immunosorbent Assay

    Science.gov (United States)

    Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio

    2013-01-01

    A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700

  19. Radioimmunoassay for antibodies to rubella virus and its ribonucleoprotein component

    International Nuclear Information System (INIS)

    Ho-Terry, L.; Cohen, A.

    1979-01-01

    Using a radioimmune precipitation technique, the antibody response to intact rubella virus and its ribonucleoprotein component was measured. The method was very sensitive and reproducible, and did not require preliminary serum fractionation for the identification of antibodies of different immunoglobulin classes. The results showed that the IgA and IgG antibodies against the intact virus persisted in the sera of patients long after the initial infection. In contrast, IgA and IgG antibodies against the ribonucleoprotein component of rubella virus were detected only in sera of patients after recent rubella infection. This observation suggested that a test for antibodies to the ribonucleoprotein component may provide additional evidence in the diagnosis of recent rubella infection. This could be potentially a useful test particularly in the management of pregnant patients. (U.K.)

  20. Comparative sensitivity of 125I-protein A and enzyme-conjugated antibodies for detection of immunoblotted proteins

    International Nuclear Information System (INIS)

    Bernstein, J.M.; Stokes, C.E.; Fernie, B.

    1987-01-01

    Immunoblotting is a powerful technique for the detection of small amounts of immunologically interesting proteins in unpurified preparations. Iodinated protein A (PA) has been widely used as a second antibody for detection of proteins; however, it does not bind equally well to immunoglobulins from different species nor does it bind to all subclasses of immunoglobulin G (IgG). We compared the sensitivity of [ 125 I]PA with those of both horseradish peroxidase-conjugated second antibodies (HRP) and glucose oxidase-anti-glucose oxidase (GAG) soluble complexes for visualizing bovine serum albumin, human IgG, or human C3 which was either dot blotted or electroblotted to nitrocellulose. [ 125 I]PA was uniformly 10- to 100-fold less sensitive than either HRP or GAG. GAG was more sensitive than HRP except for C3 (electroblotting) and bovine serum albumin and IgG (dot blotting), in which they were equivalent. In general, dot blotting was 10- to 1000-fold more sensitive than electroblotting. Although relative sensitivities varied depending on the proteins analyzed and the antisera used, GAG appeared to be superior to [ 125 I]PA and HRP for detection of immunoblotted proteins

  1. Breaking the color barrier - a multi-selective antibody reporter offers innovative strategies of fluorescence detection.

    Science.gov (United States)

    Gallo, Eugenio; Jarvik, Jonathan W

    2017-08-01

    A novel bi-partite fluorescence platform exploits the high affinity and selectivity of antibody scaffolds to capture and activate small-molecule fluorogens. In this report, we investigated the property of multi-selectivity activation by a single antibody against diverse cyanine family fluorogens. Our fluorescence screen identified three cell-impermeant fluorogens, each with unique emission spectra (blue, green and red) and nanomolar affinities. Most importantly, as a protein fusion tag to G-protein-coupled receptors, the antibody biosensor retained full activity - displaying bright fluorogen signals with minimal background on live cells. Because fluorogen-activating antibodies interact with their target ligands via non-covalent interactions, we were able to perform advanced multi-color detection strategies on live cells, previously difficult or impossible with conventional reporters. We found that by fine-tuning the concentrations of the different color fluorogen molecules in solution, a user may interchange the fluorescence signal (onset versus offset), execute real-time signal exchange via fluorogen competition, measure multi-channel fluorescence via co-labeling, and assess real-time cell surface receptor traffic via pulse-chase experiments. Thus, here we inform of an innovative reporter technology based on tri-color signal that allows user-defined fluorescence tuning in live-cell applications. © 2017. Published by The Company of Biologists Ltd.

  2. PERFORMANCE EVALUATION OF A PROTOTYPE ARCHITECT ANTIBODY ASSAY FOR BABESIA MICROTI.

    Science.gov (United States)

    Cheng, Kevin; Coller, Kelly E; Marohnic, Christopher C; Pfeiffer, Zachary A; Fino, James R; Elsing, Randee R; Bergsma, Janet; Marcinkus, Marilee A; Kar, Alak K; Gumbs, Orlando H; Otis, Kathy S; Fishpaugh, Jeffrey; Schultz, Phillip W; Pope, Mark R; Narvaez, Alfredo R; Wong, Susan J; Madison-Antenucci, Susan; Leary, Thomas P; Dawson, George J

    2018-05-09

    The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the ARCHITECT instrument. The specificity was determined to be 99.98% in volunteer blood donors (n=28,740) from areas considered as low endemic for B. microti The sensitivity of the prototype test was studied in experimentally-infected macaques; a total of 128 samples were detected compared to 125 with the indirect fluorescent antibody test (IFA), additionally, 83 (89.2%) of the PCR positive samples were detected compared to 81 (87.1%) using the IFA test. All PCR positive samples that tested negative in the prototype antibody test were pre-seroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR negative samples drawn in-between PCR positive bleed dates, tested positive both by the prototype test (robust reactivity) and IFA (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window period parasitemia, antibody tests detect infected subjects during periods of low level parasitemia. Copyright © 2018 Cheng et al.

  3. Generation of monoclonal antibodies against prostate specific antigen (PSA) for the detection of PSA and its purification

    International Nuclear Information System (INIS)

    Acevedo Castro, Boris Ernesto

    2012-01-01

    The prostate cancer in Cuba is a problem of health (2672 diagnosed cases and 2769 deaths in 2007). Various diagnostic methods have been implemented for the detection and management of this disease, emphasizing among them (PSA) prostate-specific antigen serological determination. At this work was generated and characterized a panel of 11 antibodies (AcMs) monoclonal IgG1 detected with high affinity described major epitopes of the PSA, both in solution and attached to the test plate. From the panel obtained AcMs was the standardization of an essay type ELISA for the detection of serum total PSA (associated and free) equimolar, based on antibody monoclonal CB-PSA.4 in the coating and the CB-PSA.9 coupled with biotin as liner, with a detection limit of 0.15 ng/mL. Similarly, standardized system for detection in serum free PSA, based on the AcMs CB-PSA.4 (coating) and CB-PSA.2 coupled with biotin (liner), with a detection limit of 0.5 ng/mL. Finally, with the purpose of using PSA as standard in trials type ELISA, developed a simple method of inmunopurificación based on the AcM, CB-PSA.2, which was obtained the PSA with a purity exceeding 90%. Immunoassay Centre on the basis of the AcMs panel and the results of this study, developed and recorded two diagnostic systems for the detection of PSA in human serum. (author)

  4. A novel method for the detection of antibodies to adalimumab in the presence of drug reveals "hidden" immunogenicity in rheumatoid arthritis patients

    NARCIS (Netherlands)

    van Schouwenburg, Pauline A.; Bartelds, Geertje M.; Hart, Margreet H.; Aarden, Lucien; Wolbink, Gerrit Jan; Wouters, Diana

    2010-01-01

    Production of anti drug antibodies (ADA) in adalimumab treated RA patients is associated with reduced serum adalimumab levels and less clinical response. However, most current assays to measure ADA are unable to detect ADA in complex with adalimumab. Thus, ADA is only measured if antibody production

  5. Development of a Nucleoprotein-Based Enzyme-Linked Immunosorbent Assay Using a Synthetic Peptide Antigen for Detection of Avian Metapneumovirus Antibodies in Turkey Sera

    Science.gov (United States)

    Alvarez, Rene; Njenga, M. Kariuki; Scott, Melissa; Seal, Bruce S.

    2004-01-01

    Avian metapneumoviruses (aMPV) cause an upper respiratory tract disease with low mortality but high morbidity, primarily in commercial turkeys, that can be exacerbated by secondary infections. There are three types of aMPV, of which type C is found only in the United States. The aMPV nucleoprotein (N) amino acid sequences of serotypes A, B, and C were aligned for comparative analysis. On the basis of the predicted antigenicity of consensus sequences, five aMPV-specific N peptides were synthesized for development of a peptide antigen enzyme-linked immunosorbent assay (aMPV N peptide-based ELISA) to detect aMPV-specific antibodies among turkeys. Sera from naturally and experimentally infected turkeys were used to demonstrate the presence of antibodies reactive to the chemically synthesized aMPV N peptides. Subsequently, aMPV N peptide 1, which had the sequence 10-DLSYKHAILKESQYTIKRDV-29, with variations at only three amino acids among aMPV serotypes, was evaluated as a universal aMPV ELISA antigen. Data obtained with the peptide-based ELISA correlated positively with total aMPV viral antigen-based ELISAs, and the peptide ELISA provided higher optical density readings. The results indicated that aMPV N peptide 1 can be used as a universal ELISA antigen to detect antibodies for all aMPV serotypes. PMID:15013970

  6. Next Generation Antibody Therapeutics Using Bispecific Antibody Technology.

    Science.gov (United States)

    Igawa, Tomoyuki

    2017-01-01

    Nearly fifty monoclonal antibodies have been approved to date, and the market for monoclonal antibodies is expected to continue to grow. Since global competition in the field of antibody therapeutics is intense, we need to establish novel antibody engineering technologies to provide true benefit for patients, with differentiated product values. Bispecific antibodies are among the next generation of antibody therapeutics that can bind to two different target antigens by the two arms of immunoglobulin G (IgG) molecule, and are thus believed to be applicable to various therapeutic needs. Until recently, large scale manufacturing of human IgG bispecific antibody was impossible. We have established a technology, named asymmetric re-engineering technology (ART)-Ig, to enable large scale manufacturing of bispecific antibodies. Three examples of next generation antibody therapeutics using ART-Ig technology are described. Recent updates on bispecific antibodies against factor IXa and factor X for the treatment of hemophilia A, bispecific antibodies against a tumor specific antigen and T cell surface marker CD3 for cancer immunotherapy, and bispecific antibodies against two different epitopes of soluble antigen with pH-dependent binding property for the elimination of soluble antigen from plasma are also described.

  7. Stratification of Antibody-Positive Subjects by Antibody Level Reveals an Impact of Immunogenicity on Pharmacokinetics

    OpenAIRE

    Zhou, Lei; Hoofring, Sarah A.; Wu, Yu; Vu, Thuy; Ma, Peiming; Swanson, Steven J.; Chirmule, Narendra; Starcevic, Marta

    2012-01-01

    The availability of highly sensitive immunoassays enables the detection of antidrug antibody (ADA) responses of various concentrations and affinities. The analysis of the impact of antibody status on drug pharmacokinetics (PK) is confounded by the presence of low-affinity or low-concentration antibody responses within the dataset. In a phase 2 clinical trial, a large proportion of subjects (45%) developed ADA following weekly dosing with AMG 317, a fully human monoclonal antibody therapeutic....

  8. Detection of Signal Regulatory Protein α in Saimiri sciureus (Squirrel Monkey) by Anti-Human Monoclonal Antibody

    Science.gov (United States)

    de Souza, Hugo Amorim dos Santos; Costa-Correa, Edmar Henrique; Bianco-Junior, Cesare; Andrade, Márcia Cristina Ribeiro; Lima-Junior, Josué da Costa; Pratt-Riccio, Lilian Rose; Daniel-Ribeiro, Cláudio Tadeu; Totino, Paulo Renato Rivas

    2017-01-01

    Non-human primates (NHP) are suitable models for studying different aspects of the human system, including pathogenesis and protective immunity to many diseases. However, the lack of specific immunological reagents for neo-tropical monkeys, such as Saimiri sciureus, is still a major factor limiting studies in these models. An alternative strategy to circumvent this obstacle has been the selection of immunological reagents directed to humans, which present cross-reactivity with NHP molecules. In this context and considering the key role of inhibitory immunoreceptors—such as the signal regulatory protein α (SIRPα)—in the regulation of immune responses, in the present study, we attempted to evaluate the ability of anti-human SIRPα monoclonal antibodies to recognize SIRPα in antigen-presenting S. sciureus peripheral blood mononuclear cells (PBMC). As shown by flow cytometry analysis, the profile of anti-SIRPα staining as well as the levels of SIRPα-positive cells in PBMC from S. sciureus were similar to those observed in human PBMC. Furthermore, using anti-SIRPα monoclonal antibody, it was possible to detect a decrease of the SIRPα levels on surface of S. sciureus cells after in vitro stimulation with lipopolysaccharides. Finally, using computed-based analysis, we observed a high degree of conservation of SIRPα across six species of primates and the presence of shared epitopes in the extracellular domain between humans and Saimiri genus that could be targeted by antibodies. In conclusion, we have identified a commercially available anti-human monoclonal antibody that is able to detect SIRPα of S. sciureus monkeys and that, therefore, can facilitate the study of the immunomodulatory role of SIRPα when S. sciureus is used as a model. PMID:29312325

  9. Detection of Signal Regulatory Protein α in Saimiri sciureus (Squirrel Monkey by Anti-Human Monoclonal Antibody

    Directory of Open Access Journals (Sweden)

    Hugo Amorim dos Santos de Souza

    2017-12-01

    Full Text Available Non-human primates (NHP are suitable models for studying different aspects of the human system, including pathogenesis and protective immunity to many diseases. However, the lack of specific immunological reagents for neo-tropical monkeys, such as Saimiri sciureus, is still a major factor limiting studies in these models. An alternative strategy to circumvent this obstacle has been the selection of immunological reagents directed to humans, which present cross-reactivity with NHP molecules. In this context and considering the key role of inhibitory immunoreceptors—such as the signal regulatory protein α (SIRPα—in the regulation of immune responses, in the present study, we attempted to evaluate the ability of anti-human SIRPα monoclonal antibodies to recognize SIRPα in antigen-presenting S. sciureus peripheral blood mononuclear cells (PBMC. As shown by flow cytometry analysis, the profile of anti-SIRPα staining as well as the levels of SIRPα-positive cells in PBMC from S. sciureus were similar to those observed in human PBMC. Furthermore, using anti-SIRPα monoclonal antibody, it was possible to detect a decrease of the SIRPα levels on surface of S. sciureus cells after in vitro stimulation with lipopolysaccharides. Finally, using computed-based analysis, we observed a high degree of conservation of SIRPα across six species of primates and the presence of shared epitopes in the extracellular domain between humans and Saimiri genus that could be targeted by antibodies. In conclusion, we have identified a commercially available anti-human monoclonal antibody that is able to detect SIRPα of S. sciureus monkeys and that, therefore, can facilitate the study of the immunomodulatory role of SIRPα when S. sciureus is used as a model.

  10. Core antigen and circulating anti-core antibody in hepatitis B infection

    Energy Technology Data Exchange (ETDEWEB)

    Howard, C R; Zuckerman, A J [London School of Hygiene and Tropical Medicine (UK)

    1977-02-01

    Core antigen was obtained from the sera of persistent chronic carriers of hepatitis B virus by centrifugation and treatment with Nonidet P40 and 2-mercaptoethanol. The separated core antigen was radiolabelled and identified as a nucleoprotein structure of buoyant density 1.36 g/cm/sup 3/ and possessing an isoelectric point of 4.4. This material was employed in a radioimmnoassay procedure of high sensitivity for the detection of core antibody. In a series of sera from patients with acute type B hepatitis, core antibody was demonstrated 2 to 3 weeks after the onset of jaundice during the period of surface antigenaemia. The presence of core antibody may therefore provide an accurate serological marker for the detection of active or recent virus replication in future epidemiological studies of hepatitis B infection.

  11. The detection of ovarian cancer using 123I monoclonal antibody

    International Nuclear Information System (INIS)

    Granowska, M.; Britton, K.E.; Shepherd, J.

    1984-01-01

    The technique of the production of monoclonal antibodies is described. Antibodies show reactivity with epithelial surfaces of cancer of breast, colon and ovary. The iodogen reaction is used for labelling monoclonal antibodies with 123 I. Description of labelling technique and quality control. After intravenous injection of 74 MBq 123 I-labelled monoclonal antibody (0.5 mg) static camera images of the abdomen were recorded at 10 min, 4 and 22 hours in anterior and posterior position. 20 out of 22 patients with ovarian cancer with and without metastases were correctly diagnosed and confirmed at surgery. (author)

  12. Radioimmunodetection of hepatocellular carcinoma with a radiolabeled antibody to alpha fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, N; Nakata, K; Muro, T [Nagasaki Univ. (Japan). School of Medicine

    1982-03-01

    The present study was undertaken to investigate whether or not radiolabeled antibody to Alpha-fetoprotein (AFP) intravenously administered accumulates in AFP-producing tumors. Rats with subcutaneously transplanted hepatoma or with heptoma produced in liver by 3'-Me-DAB, and 12 patients with hepatocellular carcinoma (HCC) were studied. In animal experiments, the tumor localization was clearly demonstrated by total body scintigraphy 48 to 168 hours after the injection of the radioiodinated antibody. The rats were sacrificed and radioactivity in tissues was counted. Tumor tissues showed the highest counts. In patients with HCC, the imaging was made with a gamma camera usually 24 and 48 hours after injection of I-131-labeled antibody. In order to make the contrast of tumor image clear, nonspecific background images obtained by administration of Tc-99m-labeled serum albumin were subtracted from the images obtained by I-131 labeled antibody with a computer. In 6 of 12 patients with HCC, the tumor location could successfully demonstrated. However, tumor with sizes below 2 cm in diameter which were able to be detected by the celiac angiography were not detectable. Interestingly the images were more clear in patients with relatively higher serum AFP levels. In the blood of patient given injection of AFP radioantibody, both immune complex and free antibody were able to be detected at least for 120 hours so that the presence of free antigen (AFP) did not appear to prevent tumor radioimmunodetection. The information obtained concerning the biochemical factors which influence antibody localization in the tumor would provide better method for radioimmunodetection with antitumor antibodies.

  13. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Science.gov (United States)

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933, and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli. PMID:22919675

  14. [Contribution of the detection of IgA antibodies to the laboratory diagnosis of mumps in the population with a high vaccination coverage].

    Science.gov (United States)

    Limberková, R; Smíšková, D; Havlíčková, M; Herrmannová, K; Lexová, P; Malý, M

    2015-03-01

    Serological diagnosis of epidemic mumps can be difficult in vaccinated persons, particularly due to the absence of specific IgM antibodies. The aim was to find whether adding the detection of IgA antibodies to the currently used routine serological diagnosis of mumps (detection of IgM and IgG antibodies in an acute serum sample) would make the serological diagnosis of mumps more effective in a population with a high vaccination coverage. At the same time, ELISA kits for the detection of early IgA and IgM antibodies against the mumps virus were compared and statistical analysis of the results was performed. Sixty-four acute sera from patients with laboratory confirmed diagnosis of mumps were included in the study. Clinical specimens were collected at the onset of clinical symptoms. To test the sera, the MASTAZYME ELISA Mumps IgA kit (MAST DIAGNOSTICA, Germany) with the MASTSORB sorbent (RF and IgG) and Enzygnost Anti-Parotitis-Virus/IgM kit (Siemens, Germany) were used. A panel of 121 acute sera with no epidemiological link to mumps virus served as specificity controls for the IgA assay. The epidemiological data were derived from the EPIDAT system. The level of agreement was assessed using the McNemara test and Cohen's coefficient kappa. The Stata 9.2 software (Stata Corp LP, College Station, USA) was used for statistical analysis. The detection of IgA and IgM antibodies against the mumps virus yielded concordant results in 50/64 acute sera, 32 positive and 18 negative, i.e. an agreement of 78.12 %. Of the remaining 14 samples, 13 were only IgA positive and one was only IgM positive. The controls showed non-specific IgA positivity in 5/121 samples which indicates a 96% specificity. The absence of specific IgM antibodies against mumps virus is relatively often seen in vaccinated indivi-duals; nevertheless, the test is routinely used in patients with suspected active infection. The test for IgA antibodies, which is not routinely performed, significantly increased the

  15. NMR Detection of Semi-Specific Antibody Interactions in Serum Environments

    Directory of Open Access Journals (Sweden)

    Saeko Yanaka

    2017-09-01

    Full Text Available Although antibody functions are executed in heterogeneous blood streams characterized by molecular crowding and promiscuous intermolecular interaction, detailed structural characterizations of antibody interactions have thus far been performed under homogeneous in vitro conditions. NMR spectroscopy potentially has the ability to study protein structures in heterogeneous environments, assuming that the target protein can be labeled with NMR-active isotopes. Based on our successful development of isotope labeling of antibody glycoproteins, here we apply NMR spectroscopy to characterize antibody interactions in heterogeneous extracellular environments using mouse IgG-Fc as a test molecule. In human serum, many of the HSQC peaks originating from the Fc backbone exhibited attenuation in intensity of various magnitudes. Similar spectral changes were induced by the Fab fragment of polyclonal IgG isolated from the serum, but not by serum albumin, indicating that a subset of antibodies reactive with mouse IgG-Fc exists in human serum without preimmunization. The metaepitopes recognized by serum polyclonal IgG cover the entire molecular surface of Fc, including the binding sites to Fc receptors and C1q. In-serum NMR observation will offer useful tools for the detailed characterization of biopharamaceuticals, including therapeutic antibodies in physiologically relevant heterogeneous environments, also giving deeper insight into molecular recognition by polyclonal antibodies in the immune system.

  16. Comparison of printed glycan array, suspension array and ELISA in the detection of human anti-glycan antibodies.

    Science.gov (United States)

    Pochechueva, Tatiana; Jacob, Francis; Goldstein, Darlene R; Huflejt, Margaret E; Chinarev, Alexander; Caduff, Rosemarie; Fink, Daniel; Hacker, Neville; Bovin, Nicolai V; Heinzelmann-Schwarz, Viola

    2011-12-01

    Anti-glycan antibodies represent a vast and yet insufficiently investigated subpopulation of naturally occurring and adaptive antibodies in humans. Recently, a variety of glycan-based microarrays emerged, allowing high-throughput profiling of a large repertoire of antibodies. As there are no direct approaches for comparison and evaluation of multi-glycan assays we compared three glycan-based immunoassays, namely printed glycan array (PGA), fluorescent microsphere-based suspension array (SA) and ELISA for their efficacy and selectivity in profiling anti-glycan antibodies in a cohort of 48 patients with and without ovarian cancer. The ABO blood group glycan antigens were selected as well recognized ligands for sensitivity and specificity assessments. As another ligand we selected P(1), a member of the P blood group system recently identified by PGA as a potential ovarian cancer biomarker. All three glyco-immunoassays reflected the known ABO blood groups with high performance. In contrast, anti-P(1) antibody binding profiles displayed much lower concordance. Whilst anti-P(1) antibody levels between benign controls and ovarian cancer patients were significantly discriminated using PGA (p=0.004), we got only similar results using SA (p=0.03) but not for ELISA. Our findings demonstrate that whilst assays were largely positively correlated, each presents unique characteristic features and should be validated by an independent patient cohort rather than another array technique. The variety between methods presumably reflects the differences in glycan presentation and the antigen/antibody ratio, assay conditions and detection technique. This indicates that the glycan-antibody interaction of interest has to guide the assay selection. © The Author(s) 2011. This article is published with open access at Springerlink.com

  17. Solid phase radioimmunoassay for detection of malaria antigen. Comparison of monoclonal and polyclonal antibodies

    International Nuclear Information System (INIS)

    Khusmith, S.; Tharavanij, S.; Patarapotikul, J.; Kasemsuth, R.; Bunnag, D.

    1986-01-01

    A solid phase competitive binding radioimmunoassay (RIA) was developed for the detection of Plasmodium falciparum in infected blood. A suspension of NP40 treated red blood cells was mixed with labelled antimalarial IgG, incubated and then added to malarial antigen coated microtitre plate. Antimalarial IgGs were purified either from high titre sera from individuals living in a malaria endemic area in Thailand or from a locally produced monoclonal antibody (MAB) which showed a bright generalized immunofluorescent staining pattern against all blood stages of P. falciparum, including gametocytes. This MAB reacted with 27 of 31 P. falciparum isolates from Thailand. Using dilution of red blood cells from in vitro cultures of P. falciparum, the test was found to detect parasites at levels equivalent to 13 and 2.2 parasites/10 6 red blood cells with labelled polyclonal IgG (PIgG) and labelled monoclonal IgG (MIgG), respectively. No false positive results were obtained among samples from non-malarial subjects. Of the samples that gave negative results upon microscopic examination, 50 and 35% were still positive with RIA using MIgG and PIgG, respectively. There was a correlation between RIA and the number of parasites, especially when MIgG was used. The results indicate that the IgG fraction of sera from individuals with natural acquired immunity to malaria showed a lower degree of sensitivity in parasite detection than the IgG from monoclonal antibody. (author)

  18. [Establishment of chemiluminescent enzyme immunoassay for detecting antibodies against foot-and-mouth disease virus serotype O in swine].

    Science.gov (United States)

    Cui, Chen; Huang, Ligang; Li, Jing; Zou, Xingqi; Zhu, Yuanyuan; Xie, Lei; Zhao, Qizu; Yang, Limin; Liu, Wenjun

    2016-11-25

    Recombinant structural protein VP1 of foot-and-mouth disease virus serotype O was expressed in Escherichia coli and then purified using Nickel affinity chromatography. A chemiluminescent enzyme immunoassay (CLEIA) method was established using the purified recombinant protein as coating antigen to detect antibody of foot-and-mouth disease virus serotype O in swine. The specificity of VP1-CLEIA method is 100%. The coefficients of variation in the plate and between plates are 1.10%-6.70% and 0.66%-4.80%, respectively. Comparing with the commercial indirect ELISA kit or liquid phase block ELISA kit, the calculated coincidence rate is 93.50% or 94.00%. The high specificity and stability suggested this detection method can be used to monitor the antibody level of foot-and-mouth disease virus serotype O in swine.

  19. Production and characterization of monoclonal antibodies against α-globin chain-containing human hemoglobins for detecting α-thalassemia disease.

    Science.gov (United States)

    Pakdeepak, Kanet; Pata, Supansa; Chiampanichayakul, Sawitree; Kasinrerk, Watchara; Tatu, Thanusak

    2016-01-01

    Monoclonal antibodies against α-globin containing human Hbs, named AMS-Alpha1 and AMS-Alpha 2, were produced by the hybridoma technique using spleen cells enriched by the newly developed B lymphocyte enrichment protocol. These two monoclonal antibodies were of IgM class, reacting to only intact form of human Hbs A, A2, E, and F, which contain α-globin chain. By the indirect ELISA, the AMS-Alpha1 and AMS-Alpha 2 quantified less amount of α-globin chain containing hemoglobins in HbH disease than the SEA-α thalassemia 1 carriers and normal individuals. It was thus anticipated that these monoclonal antibodies can be used for detecting Hb Bart's hydrops fetalis in which no α-globin chain is produced.

  20. Detection of antibody against antigen expressed by molecularly cloned hepatitis C virus cDNA: Application to diagnosis and blood screening for posttransfusion hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Miyamura, Tatsuo; Saito, Izumu (National Institute of Health, Tokyo (Japan)); Katayama, Tohru (Tokyo National Chest Hospital (Japan)); Kikuchi, Shu; Tateda, Akira (Sendai National Hospital (Japan)); Houghton, M.; Choo, Quilim; Kuo, G. (Chiron Corporation, Emeryville, CA (USA))

    1990-02-01

    A cDNA clone has been derived from the plasma of a chimpanzee with chronic non-A, non-B viral hepatits (NANBH). The authors have assayed for antibodies reacting with the encoded antigen in sera from posttransfusion hepatitis patients (643 samples from 23 patients) and their corresponding donors collected during the past 10 years in Japan. The antibody was detected in 15 out of 17 (88.2%) posttransfusion NANBH (PT-NANBH) patients whose sera over time displayed multiple alanine aminotransferase (ALT) peaks. In general, the antibody was detected after several peaks of serum ALT elevations and, once detected, it persisted for years. Of the 15 well-defined cases of PT-NANBH that showed multiple ALT peaks and hepatitis C virus seroconversions, 11 (73.3%) were shown to be transfused with at least one unit of blood positive for the antibody. The retrospective analysis showed that all tested donor blood found to be positive for the antibody had been transfused to recipients who afterwards developed NANBH. These data strongly suggest that the cloned cDNA originated from an etiological agent of NANBH termed the hepatitis C virus. Furthermore, the present study demonstrates that had the screening been done with the anti-hepatitis C virus assay, 11 out of 17 (64.7%) cases of chronic PT-NANBH and 1 out of 6 (16.6%) acute PT-NANBH would have been prevented.

  1. Detection of antibody against antigen expressed by molecularly cloned hepatitis C virus cDNA: Application to diagnosis and blood screening for posttransfusion hepatitis

    International Nuclear Information System (INIS)

    Miyamura, Tatsuo; Saito, Izumu; Katayama, Tohru; Kikuchi, Shu; Tateda, Akira; Houghton, M.; Choo, Quilim; Kuo, G.

    1990-01-01

    A cDNA clone has been derived from the plasma of a chimpanzee with chronic non-A, non-B viral hepatits (NANBH). The authors have assayed for antibodies reacting with the encoded antigen in sera from posttransfusion hepatitis patients (643 samples from 23 patients) and their corresponding donors collected during the past 10 years in Japan. The antibody was detected in 15 out of 17 (88.2%) posttransfusion NANBH (PT-NANBH) patients whose sera over time displayed multiple alanine aminotransferase (ALT) peaks. In general, the antibody was detected after several peaks of serum ALT elevations and, once detected, it persisted for years. Of the 15 well-defined cases of PT-NANBH that showed multiple ALT peaks and hepatitis C virus seroconversions, 11 (73.3%) were shown to be transfused with at least one unit of blood positive for the antibody. The retrospective analysis showed that all tested donor blood found to be positive for the antibody had been transfused to recipients who afterwards developed NANBH. These data strongly suggest that the cloned cDNA originated from an etiological agent of NANBH termed the hepatitis C virus. Furthermore, the present study demonstrates that had the screening been done with the anti-hepatitis C virus assay, 11 out of 17 (64.7%) cases of chronic PT-NANBH and 1 out of 6 (16.6%) acute PT-NANBH would have been prevented

  2. Detection of eight different tospovirus species by a monoclonal antibody against the common epitope of NSs protein

    NARCIS (Netherlands)

    Chen, T.C.; Lu, Y.Y.; Kang, Y.C.; Li, J.T.; Yeh, Y.C.; Kormelink, R.J.M.; Yeh, S.D.

    2008-01-01

    Rabbit antisera against the nucleocapsid protein (NP) have been commonly used for detection of tospoviruses and classification into serogroups or serotypes. Mouse monoclonal antibodies (MAbs) with high specificity to the NPs have also been widely used to identify tospovirus species. Recently, a

  3. Production of monoclonal antibodies for sandwich immunoassay detection of Pacific ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2010-10-01

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of Pacific ciguatoxins CTX3C and 51-hydroxyCTX3C were prepared by immunization of mice with the protein conjugates of rationally designed synthetic haptens in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C or 51-hydroxyCTX3C. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C and 51-hydroxyCTX3C at the ppb level with no cross-reactivity against the other marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin. Copyright 2009 Elsevier Ltd. All rights reserved.

  4. [Detection of serum anti-salivary duct antibody and its clinical significance].

    Science.gov (United States)

    Zhang, H; Shi, G Y; Cai, X H

    1990-11-01

    The authors developed an indirect immunofluorescence technique for the detection of Anti-salivary duct antibody (ASDA) and screened 34 patients with rheumatoid arthritis, 15 patients with Sjögren's syndrome-rheumatoid arthritis and 15 patients with primary Sjögren's syndrome, 63 cases with other connective tissue diseases, 9 cases with other diseases and 40 normal controls. The incidence of ASDA in patients with Sjögren's syndrome rheumatoid arthritis (66.67%) or rheumatoid arthritis (32.35%) was significantly higher than that in normal controls (P less than 0.001). In patients with primary Sjögren's syndrome and other CTDs, non-CTDs, no ASDA was found. However, in patients with Sjögren's syndrome-rheumatoid arthritis or rheumatoid arthritis alone, ASDA was not correlated with age, sex, disease duration or serological findings. The result suggests that the detection of serum ASDA might be useful in the differentiation of Sjögren's syndrome with rheumatoid arthritis from primary Sjögren's syndrome with arthralgia and/or arthritis.

  5. A new technique to detect antibody-antigen reaction (biological interactions) on a localized surface plasmon resonance (LSPR) based nano ripple gold chip

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, Iram, E-mail: iiram.qau@gmail.com [Department of Physics and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Widger, William, E-mail: widger@uh.edu [Department of Biology and Biochemistry and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Chu, Wei-Kan, E-mail: wkchu@uh.edu [Department of Physics and Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States)

    2017-07-31

    Highlights: • The nano ripple LSPR chip has monolayer molecule-coating sensitivity and specific selectivity. • Gold nano-ripple sensing chip is a low cost, and a label-free method for detecting the antibody-antigen reaction. • The plasmonic resonance shift depends upon the concentration of the biomolecules attached on the surface of the nano ripple pattern. - Abstract: We demonstrate that the gold nano-ripple localized surface plasmon resonance (LSPR) chip is a low cost and a label-free method for detecting the presence of an antigen. A uniform stable layer of an antibody was coated on the surface of a nano-ripple gold pattern chip followed by the addition of different concentrations of the antigen. A red shift was observed in the LSPR spectral peak caused by the change in the local refractive index in the vicinity of the nanostructure. The LSPR chip was fabricated using oblique gas cluster ion beam (GCIB) irradiation. The plasmon-resonance intensity of the scattered light was measured by a simple optical spectroscope. The gold nano ripple chip shows monolayer scale sensitivity and high selectivity. The LSPR substrate was used to detect antibody-antigen reaction of rabbit X-DENTT antibody and DENTT blocking peptide (antigen).

  6. CLINICAL-EVALUATION OF A MODIFIED ELISA, USING PHOTOBIOTINYLATED DNA, FOR THE DETECTION OF ANTI-DNA ANTIBODIES

    NARCIS (Netherlands)

    HYLKEMA, MN; HUYGEN, H; KRAMERS, C; VANDERWAL, TJ; DEJONG, J; VANBRUGGEN, MCJ; SWAAK, AJG; BERDEN, JHM; SMEENK, RJT; Hylkema, Machteld

    1994-01-01

    The measurement of anti-dsDNA antibodies is important for the diagnosis and the follow-up of patients with systemic lupus erythematosus (SLE). For routine detection of anti-dsDNA, the Farr assay and the immunofluorescence technique (IFT) on Crithidia luciliae proved to be very useful. The anti-dsDNA

  7. Compact quantum dot-antibody conjugates for FRET immunoassays with subnanomolar detection limits

    Science.gov (United States)

    Mattera, Lucia; Bhuckory, Shashi; Wegner, K. David; Qiu, Xue; Agnese, Fabio; Lincheneau, Christophe; Senden, Tim; Djurado, David; Charbonnière, Loïc J.; Hildebrandt, Niko; Reiss, Peter

    2016-05-01

    A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post-functionalization with a heterobifunctional crosslinker, containing a lipoic acid group and a maleimide function, enabled the subsequent coupling to sulfhydryl groups of proteins. This was demonstrated by QD conjugation with fragmented antibodies (F(ab)). The obtained F(ab)-QD conjugates range among the smallest antibody-functionalized nanoprobes ever reported, with a hydrodynamic diameter coating for FRET could be demonstrated by an 6.2 and 2.5 fold improvement of the limit of detection (LOD) for PSA compared to commercially available hydrophilic QDs emitting at 605 and 705 nm, respectively. While the commercial QDs contain identical inorganic cores responsible for their fluorescence, they are coated with a comparably thick amphiphilic polymer layer leading to much larger hydrodynamic diameters (>26 nm without biomolecules). The LODs of 0.8 and 3.7 ng mL-1 obtained in 50 μL serum samples are below the clinical cut-off level of PSA (4 ng mL-1) and demonstrate their direct applicability in clinical diagnostics.A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post

  8. Use of a Granulocyte Immunofluorescence Assay Designed for Humans for Detection of Antineutrophil Cytoplasmic Antibodies in Dogs with Chronic Enteropathies.

    Science.gov (United States)

    Florey, J; Viall, A; Streu, S; DiMuro, V; Riddle, A; Kirk, J; Perazzotti, L; Affeldt, K; Wagner, R; Vaden, S; Harris, T; Allenspach, K

    2017-07-01

    Perinuclear antineutrophil cytoplasmic antibodies (pANCA) previously have been shown to be serum markers in dogs with chronic enteropathies, with dogs that have food-responsive disease (FRD) having higher frequencies of seropositivity than dogs with steroid-responsive disease (SRD). The indirect immunofluorescence (IIF) assay used in previous publications is time-consuming to perform, with low interobserver agreement. We hypothesized that a commercially available granulocyte IIF assay designed for humans could be used to detect perinuclear antineutrophil cytoplasmic antibodies in dogs. Forty-four dogs with FRD, 20 dogs with SRD, 20 control dogs, and 38 soft-coated wheaten terrier (SCWT) or SCWT-cross dogs. A granulocyte assay designed for humans was used to detect pANCA, cANCA, and antinuclear antibodies (ANA), as well as antibodies against proteinase-3 protein (PR-3) and myeloperoxidase protein (MPO) in archived serum samples. Sensitivity of the granulocyte assay to predict FRD in dogs was 0.61 (95% confidence interval (CI), 0.45, 0.75), and specificity was 1.00 (95% CI, 0.91, 1.00). A significant association was identified between positive pANCA or cANCA result and diagnosis of FRD (P < 0.0001). Agreement between the two assays to detect ANCA in the same serum samples from SCWT with protein-losing enteropathy/protein-losing nephropathy (PLE/PLN) was substantial (kappa, 0.77; 95% CI, 0.53, 1.00). Eight ANCA-positive cases were positive for MPO or PR-3 antibodies. The granulocyte immunofluorescence assay used in our pilot study was easy and quick to perform. Agreement with the previously published method was good. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  9. Microangiopathic antiphospholipid antibody syndrome due to anti-phosphatidylserine/prothrombin complex IgM antibody.

    Science.gov (United States)

    Senda, Yumi; Ohta, Kazuhide; Yokoyama, Tadafumi; Shimizu, Masaki; Furuichi, Kengo; Wada, Takashi; Yachie, Akihiro

    2017-03-01

    Herein we describe a case of microangiopathic antiphospholipid syndrome (MAPS) due to anti-phosphatidylserine/prothrombin complex (aPS/PT) IgM antibody successfully treated with rituximab. A significant correlation was observed between the clinical course and the aPS/PT IgM antibody titer, which can rise earlier before the appearance of clinical symptoms. Rituximab can be safely and effectively used for MAPS. Although detection of only aPS/PT IgM antibody is rare, aPS/PT IgM antibody might be associated with the pathogenesis of MAPS and might be a useful marker of disease activity. © 2017 Japan Pediatric Society.

  10. Lichen planus, liver kidney microsomal (LKM1) antibodies and hepatitis C virus antibodies.

    Science.gov (United States)

    Divano, M C; Parodi, A; Rebora, A

    1992-01-01

    No anti-liver kidney microsomal (LKM1) antibodies were detected in 46 patients with LP, 16 of whom had also a chronic liver disease (CLD). In contrast, anti-hepatitis C virus (HCV) antibodies were found in 10% of patients with LP and in 50% of those with LP and CLD. Anti-HCV antibodies may be considered as a false-positive reaction in 56% of cases, especially when anti-LKM1 antibodies are present. Our findings do not support such a hypothesis, but suggest that CLD in LP patients is, at least in Italy, mostly a postviral chronic active hepatitis.

  11. Sensitive assays enable detection of serum IgG antibodies against Clostridium difficile toxin A and toxin B in healthy subjects and patients with Clostridium difficile infection.

    Science.gov (United States)

    Zhao, Xuemei; Bender, Florent; Shukla, Rajiv; Kang, John J; Caro-Aguilar, Ivette; Laterza, Omar F

    2016-04-01

    Pathogenic Clostridium difficile produces two proinflammatory exotoxins, toxin A and toxin B. Low level of serum antitoxin IgG antibodies is a risk factor for the development of primary and recurrent C. difficile infection (CDI). We developed and validated two sensitive, titer-based electrochemiluminescence assays for the detection of serum antibody levels against C. difficile toxins A and B. These assays demonstrated excellent precision. The sensitivity of the assays allowed the detection of antitoxin A and antitoxin B IgG antibodies in all tested serum samples during assay validation. The validated titer-based assays enable assessment of antitoxin A and antitoxin B IgG antibodies as potential biomarkers to identify patients with CDI at increased risk for CDI recurrence.

  12. Development and application of triple antibody sandwich enzyme-linked immunosorbent assays for begomovirus detection using monoclonal antibodies against Tomato yellow leaf curl Thailand virus.

    Science.gov (United States)

    Seepiban, Channarong; Charoenvilaisiri, Saengsoon; Warin, Nuchnard; Bhunchoth, Anjana; Phironrit, Namthip; Phuangrat, Bencharong; Chatchawankanphanich, Orawan; Attathom, Supat; Gajanandana, Oraprapai

    2017-05-30

    Tomato yellow leaf curl Thailand virus, TYLCTHV, is a begomovirus that causes severe losses of tomato crops in Thailand as well as several countries in Southeast and East Asia. The development of monoclonal antibodies (MAbs) and serological methods for detecting TYLCTHV is essential for epidemiological studies and screening for virus-resistant cultivars. The recombinant coat protein (CP) of TYLCTHV was expressed in Escherichia coli and used to generate MAbs against TYLCTHV through hybridoma technology. The MAbs were characterized and optimized to develop triple antibody sandwich enzyme-linked immunosorbent assays (TAS-ELISAs) for begomovirus detection. The efficiency of TAS-ELISAs for begomovirus detection was evaluated with tomato, pepper, eggplant, okra and cucurbit plants collected from several provinces in Thailand. Molecular identification of begomoviruses in these samples was also performed through PCR and DNA sequence analysis of the CP gene. Two MAbs (M1 and D2) were generated and used to develop TAS-ELISAs for begomovirus detection. The results of begomovirus detection in 147 field samples indicated that MAb M1 reacted with 2 begomovirus species, TYLCTHV and Tobacco leaf curl Yunnan virus (TbLCYnV), whereas MAb D2 reacted with 4 begomovirus species, TYLCTHV, TbLCYnV, Tomato leaf curl New Delhi virus (ToLCNDV) and Squash leaf curl China virus (SLCCNV). Phylogenetic analyses of CP amino acid sequences from these begomoviruses revealed that the CP sequences of begomoviruses recognized by the narrow-spectrum MAb M1 were highly conserved, sharing 93% identity with each other but only 72-81% identity with MAb M1-negative begomoviruses. The CP sequences of begomoviruses recognized by the broad-spectrum MAb D2 demonstrated a wider range of amino acid sequence identity, sharing 78-96% identity with each other and 72-91% identity with those that were not detected by MAb D2. TAS-ELISAs using the narrow-specificity MAb M1 proved highly efficient for the detection of

  13. The UW 21/123 monoclonal antibody in the radioimmunological detection of tumour tissue in the head and neck region

    International Nuclear Information System (INIS)

    Mueller, N.

    1987-01-01

    When incorporated in a radioimmunoassay the UW 21/123 the monoclonal antibody permits the diagnosis of certain squamous cell carcinoma of the cephalocervical region and is particularly reliable in the detection laryngeal carcinomas. It even permits the assessment of tumour cells that are not yet fully developed and thus still escape histological detection. (MBC) [de

  14. Development of a fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in dogs

    NARCIS (Netherlands)

    Schallig, H. D. F. H.; Schoone, G. J.; Beijer, E. G. M.; Kroon, C. C. M.; Hommers, M.; Ozbel, Y.; Ozensoy, S.; da Silva, E. S.; Cardoso, L. M.; da Silva, E. D.

    2002-01-01

    A fast agglutination screening test (FAST) for the detection of anti-Leishinania antibodies in serum samples from dogs with visceral leishmamosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In

  15. Diagnostic value and timing of serum antichlamidial antibody level evaluation during infertility workup among infertile women in whom tubal factor was detected with diagnostic laparoscopy

    Directory of Open Access Journals (Sweden)

    Serkan Kahyaoğlu

    2012-03-01

    Full Text Available OBJECTIVES: With normal hysterosalpingography (HSG results, selecting suitable candidates for the laparoscopic treatment of probable pelvic adhesions following previous pelvic inflammatory disease, it would be wise to investigate serum antibody screening against chlamidia trachomatis. It is worth to evaluate whether it is useful to detect a negative antichlamidial antibody disease for cancelling laparoscopy for a while with abnormal HSG findings. These two subjects have been investigated in study. MATERIAL AND METHODS: For detecting diagnostic value of serum antichlamidial antibody, in our infertility clinic, postoperative blood samples of 80 patients who were hospitalized for diagnostic laparoscopy to investigate infertility ethiology between May 2004 and November 2005 have been tested with microelisa method for antichlamidial IgM and IgG antibodies. HSG films of the patients performed at least one year were evaluated. Venous blood was drawn from these patients during postoperative early period for studying serum IgM and IgG antibodies of chlamidia trachomatis and the results were compared with operative findings. RESULTS: According to the antichlamidial antibody levels 60 (75% patients have not been infected with chlamidia and 20 (25% patients have been infected previously. When the patients were divided to two groups; normal and abnormal; based on preoperative HSG films; 18 (30% of the 60 patients with abnormal HSG films and 2 (10% of the 20 patients with normal HSG films had positive antichlamidial antibody levels respectively. CONCLUSION: The relationship between chlamidia trachomatis infection and tubal infertility has been demonstrated among 85% of patients with positive antichlamidial antibody levels and 46.7% of patients with negative levels who had tubal passage defects detected during diagnostic laparoscopy.

  16. Immunological Detection of Rabies Virus in Brain Tissues of Infected Dogs by Monoclonal Antibodies

    Directory of Open Access Journals (Sweden)

    Nyoman Mantik Astawa

    2010-12-01

    Full Text Available In order to establish an immunological detection of rabies virus in tissues of infected dogs, monoclonalantibodies (mAbs against rabies virus (RV were produced. The mAbs were produced by fusion of mielomacells with the lymphocytes of mice immunized with RV. The mAbs produced were then characterized andused for the detection of rabies virus in brain tissues of infected dogs. Six mAbs designated CC6, EG4,DG10, BB12, CA9 dan EB5 were used in this study. In Western blotting test, some mAbs reacted with 66KDa which is the glycoprotein of the virus. In immunoperoxidase, 2 mAbs (CC6 and DG10 detected RVin the brain of infected dogs. By direct immunoflourescence, flourescence isotyocyanate (FITC labelledDG10 mAbs detected RV in fresh and formaldehyde fixed brain tissues. RV was detected in 12 infecteddogs but not in normal uninfected dogs. In this study it was confirmed that rabies virus can be detected inthe brain tissues of infected dogs by monoclonal antibodies.

  17. Cancer imaging with CEA antibodies: historical and current perspectives.

    Science.gov (United States)

    Goldenberg, D M

    1992-01-01

    This article reviews the history and status of cancer imaging with radiolabeled antibodies against carcinoembryonic antigen (CEA). Although CEA and many other cancer-associated antigens are not distinct for neoplasia, the quantitative increase of these markers in malignant tissues provides a sufficient differential for selective antibody targeting. Animal studies with xenografted human tumors provided the first evidence of the prospects of this technology, followed by initial clinical success with purified goat whole IgG antibodies to CEA, labeled with 131I and with the use of dual-isotope subtraction methods. Subsequently, improved and earlier imaging could be accomplished with monoclonal antibody fragments, which then would permit the use of shorter-lived radionuclides, such as 111In, 123I, and 99mTc. The preferred use of a monoclonal anti-CEA IgG Fab' fragment, labeled with 99mTc by a recently developed, simple and rapid kit, has enabled the detection of small lesions, including those in the liver, within 4 h of injection. By means of SPECT imaging, a high sensitivity and specificity for RAID could be achieved.

  18. ICARE improves antinuclear antibody detection by overcoming the barriers preventing accreditation.

    Science.gov (United States)

    Bertin, Daniel; Mouhajir, Yassin; Bongrand, Pierre; Bardin, Nathalie

    2016-02-15

    Antinuclear antibodies (ANA) are useful biomarkers for the diagnosis and the monitoring of rheumatic diseases. The American College of Rheumatology has stated that indirect immunofluorescence (IIF) analysis remains the gold standard for ANA screening. However, IIF is time consuming, subjective, not fully standardized and presents several issues for accreditation which is the process leading to ISO 15189 certification for medical laboratories. We propose an innovative tool for accreditation by using the quantitative evaluation of the automated image capture and analysis "ICARE" (Immunofluorescence for Computed Antinuclear antibody Rational Evaluation). We established the optimal screening dilution (1:160) and a fluorescence index (FI) cutoff for ICARE on a cohort of 91 healthy blood donors. Then, we evaluated performance of ICARE on a routine cohort of 236 patients. Precision parameters of ANA detection by IIF were evaluated according to ISO 15189. ICARE showed an excellent concordance with visual evaluation (88%, Kappa=0.76) and significantly discriminated between weak to moderate (1:160-1:320 titers) and high (>1:320 titers) ANA levels. A significant correlation was found between FI and ANA titers (Spearman's ρ=0.67; Pprocess of continuous improvement of the quality of clinical laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Heterologous Coproduction of Enterocin A and Pediocin PA-1 by Lactococcus lactis: Detection by Specific Peptide-Directed Antibodies

    Science.gov (United States)

    Martínez, José M.; Kok, Jan; Sanders, Jan W.; Hernández, Pablo E.

    2000-01-01

    Antibodies against enterocin A were obtained by immunization of rabbits with synthetic peptides PH4 and PH5 designed, respectively, on the N- and C-terminal amino acid sequences of enterocin A and conjugated to the carrier protein KLH. Anti-PH4-KLH antibodies not only recognized enterocin A but also pediocin PA-1, enterocin P, and sakacin A, three bacteriocins which share the N-terminal class IIa consensus motif (YGNGVXC) that is contained in the sequence of the peptide PH4. In contrast, anti-PH5-KLH antibodies only reacted with enterocin A because the amino acid sequences of the C-terminal parts of class IIa bacteriocins are highly variable. Enterocin A and/or pediocin PA-1 structural and immunity genes were introduced in Lactococcus lactis IL1403 to achieve (co)production of the bacteriocins. The level of production of the two bacteriocins was significantly lower than that obtained by the wild-type producers, a fact that suggests a low efficiency of transport and/or maturation of these bacteriocins by the chromosomally encoded bacteriocin translocation machinery of IL1403. Despite the low production levels, both bacteriocins could be specifically detected and quantified with the anti-PH5-KLH (anti-enterocin A) antibodies isolated in this study and the anti-PH2-KLH (anti-pediocin PA-1) antibodies previously generated (J. M. Martínez, M. I. Martínez, A. M. Suárez, C. Herranz, P. Casaus, L. M. Cintas, J. M. Rodríguez, and P. E. Hernández, Appl. Environ. Microbiol. 64:4536–4545, 1998). In this work, the availability of antibodies for the specific detection and quantification of enterocin A and pediocin PA-1 was crucial to demonstrate coproduction of both bacteriocins by L. lactis IL1403(pJM04), because indicator strains that are selectively inhibited by each bacteriocin are not available. PMID:10919819

  20. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Directory of Open Access Journals (Sweden)

    Yanil R Parma

    2012-06-01

    Full Text Available Enterohemorrhagic Escherichia coli (EHEC, a subset of Shiga toxin producing E. coli (STEC is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic uremic syndrome (HUS. Regardless of serotype, Shiga toxins (Stx1 and/or Stx2 are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx was developed using anti-Stx2 B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933 and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 400 ng /ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for 2 strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli.

  1. Comparison between an immunochromatographic test with an amplified ELISA for detecting e antigen and anti-e antigen antibodies in chronic Hepatitis B

    International Nuclear Information System (INIS)

    Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Aguilar Rubido; Julio C

    2009-01-01

    The disappearance of the e antigen and the appearance of anti-e antigen antibodies are two biomarkers that indicate favorable prognosis in Hepatitis B. In this study the Advanced QualityTM immunochromatographic test for detecting those biomarkers was compared to the Vidas semi-quantitative ELISA test. Our hypothesis was that it is possible to use these biomarkers measured in a rapid and simple Advanced QualityTM immunochromatographic test for evaluating the therapeutic response in clinical trials with chronic hepatitis B patients. The two methods were done following the manufacturer's instructions. The sera were taken from 69 patients with chronic hepatitis B of the clinical trial of the CIGB 440 therapeutic candidate. The immunochromatographic test and ELISA for detecting e antigen and anti-e antigen antibodies presented from substantial to almost perfect agreement in the evaluation of the sera of chronic Hepatitis B patients in a clinical trial. The immunochromatographic test for detecting e antigen had a low positive average agreement and a high negative average agreement compared to the ELISA. Nevertheless, the immunochromatographic test for detecting anti-e antigen antibodies had a high negative and positive average agreement in comparison to the ELISA. The immunochromagraphic test for the e antigen had a lower positive average agreement compared to the ELISA and some patients infected with Hepatitis B virus could not be detected by the former assay. The immunochromatographic test for anti-e antigen antibodies showed a similar performance to that of ELISA and could therefore be used in clinical trials for chronic Hepatitis B in health institutions without the need of a highly qualified lab technician. (author)

  2. Evaluation of enzyme-linked immunosorbent assays based on monoclonal antibodies for the serology and antigen detection in canine parvovirus infections.

    NARCIS (Netherlands)

    G.F. Rimmelzwaan (Guus); N. Juntti; B. Klingeborn; J. Groen (Jan); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1990-01-01

    textabstractAn enzyme-linked immunosorbent assay (ELISA) system was developed for the detection of canine parvovirus (CPV) or CPV antigen in dog faeces and two other ELISA systems were developed for the detection of CPV-specific antibodies in dog sera. The ELISA's were based on the use of

  3. Construction, expression, purification and biotin labeling of a single recombinant multi-epitope antigen for double-antigen sandwich ELISA to detect hepatitis C virus antibody.

    Science.gov (United States)

    He, Jing; Xiu, Bingshui; Wang, Guohua; Chen, Kun; Feng, Xiaoyan; Song, Xiaoguo; Zhu, Cuixia; Yang, Xiqin; Bai, Guanzhong; Ling, Shigan; Zhang, Heqiu

    2011-08-01

    Based on B cell epitope predictions, a recombinant antigen with multiple epitopes from four Hepatitis C Virus fragments (C, NS3, NS4 and NS5) were engineered. The recombinant gene was then highly expressed in E. coli. The non-modified and C-terminal-modified recombinant proteins were used for coating and biotin labeling, respectively, to establish the double-antigen sandwich ELISA. Ten positive reference samples confirmed by the CHIRON RIBA HCV 3.0 SIA kit were detected positive, Forty one plasma samples were positive among samples from 441 volunteers, which indicated that the recombinant antigen could readily react well with plasma HCV antibody. As critical reagents of double-antigen sandwich ELISA, the recombinant multi-epitope antigen and the C-terminal-modified and biotin-conjugated antigen show good antigenicity. In this study, we provide a simple approach to produce multiple epitopes within one recombinant protein in order to avoid the costly expression of less-effective pools of multiple proteins, which is the conventional strategy of diagnostic antigen production for HCV antibody detection.

  4. Evaluation of Gamma Interferon and Antibody Tuberculosis Tests in Alpacas

    Science.gov (United States)

    Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin

    2012-01-01

    We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a “test package,” although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations. PMID:22914362

  5. Radioimmunodetection of hepatocellular carcinoma with a radiolabeled antibody to alpha fetoprotein

    International Nuclear Information System (INIS)

    Ishii, Nobuko; Nakata, Keisuke; Muro, Toyokichi

    1982-01-01

    The present study was undertaken to investigate whether or not radiolabeled antibody to Alpha-fetoprotein (AFP) intravenously administered is accumulate in AFP-producing tumors. Rats with subcutaneously transplanted hepatoma or with heptoma produced in liver by 3'-Me-DAB, and 12 patients with hepatocellular carcinoma (HCC) were studied. In animal experiments, the tumor localization was clearly demonstrated by total body scintigraphy 48 to 168 hours after the injection of the radioiodinated antibody. The rats were sacrificed and radioactivity in tissues was counted. Tumor tissues showed the highest counts. In patients with HCC, the imaging was made with a gamma camera usually 24 and 48 hours after injection of I-131-labeled antibody. In order to make the contrast of tumor image clear, nonspecific background images obtained by administration of Tc-99m-labeled serum albumin were subtracted from the images obtained by I-131 labeled antibody with a computer. In 6 of 12 patients with HCC, the tumor location could successfully demonstrated. However, tumor with sizes below 2 cm in diameter which were able to be detected by the celiac angiography were not detectable. Interes tingly the images were more clear in patients with relatively higher serum AFP levels. In the blood of patient given injection of AFP radioantibody, both immune complex and free antibody were able to be detected at least for 120 hours so that the presence of free antigen (AFP) did not appear to prevent tumor radioimmunodetection. The information obtained concerning the biochemical factors which influence antibody localization in the tumor would provide better method for radioimmunodetection with antitumor antibodies. (author)

  6. Development of microLIPS (Luciferase Immunoprecipitation Systems): a novel microfluidic assay for rapid serum antibody detection

    Science.gov (United States)

    Chandrangsu, Matt; Burbelo, Peter D.; Iadarola, Michael J.; Smith, Paul D.; Morgan, Nicole Y.

    2012-06-01

    There is considerable interest in the development of rapid, point-of-care antibody detection for the diagnosis of infectious and auto-immune diseases. In this paper, we present work on the development of a self-contained microfluidic format for the Luciferase Immunoprecipitation Systems (LIPS) assay. Whereas the majority of immunoassays for antigen-specific antibodies employ either bacteria- or yeast-expressed proteins and require the use of secondary antibodies, the LIPS technique uses a fusion protein comprised of a Renilla luciferase reporter and the antigen of interest produced via mammalian cell culture, ensuring the addition of mammalian post-translational modifications. Patient serum is mixed with the fusion protein and passed over immobilized Protein A/G; after washing, the only remaining luciferase-tagged antigens are those retained by specific antibodies. These can be quantitatively measured using chemiluminescence upon the introduction of coelenterazine. The assay has been successfully employed for a wide variety of diseases in a microwell format. We report on a recent demonstration of rapid HSV-2 diagnosis with the LIPS assay in a microfluidic format, using one microliter of serum and obtaining results in under ten minutes. We will also discuss recent progress on two fronts, both aimed at the deployment of this technology in the field: first, simplifying assay operation through the automation of flow control using power-free means; and second, efforts to increase signal levels, primarily through strategies to increase antibody binding capacity, in order to move towards portable battery powered electronics.

  7. A simple sandwich ELISA (WELYSSA) for the detection of lyssavirus nucleocapsid in rabies suspected specimens using mouse monoclonal antibodies.

    Science.gov (United States)

    Xu, Gelin; Weber, Patrick; Hu, Qiaoling; Xue, Honggang; Audry, Laurent; Li, Chengping; Wu, Jie; Bourhy, Herve

    2007-10-01

    Monoclonal antibody (MAb)-based capture enzyme-linked immunosorbent assays (ELISA) were developed for the diagnosis of rabies-suspect specimens. A combination of four mouse monoclonal antibodies directed against the rabies virus nucleocapsid was selected and used for the detection. The test was optimized and standardized so that maximum concordance could be maintained with the standard procedures of rabies diagnosis recommended by the WHO expert committee. Using prototype viruses from the different genotypes of lyssavirus and from various geographic origins and phylogenetic lineages, this paper presents a reliable, rapid and transferable diagnostic method, named WELYSSA that readily permits the detection of lyssaviruses belonging to the 7 genotypes of lyssavirus circulating in Europe, Africa, Asia and Oceania. The threshold of detection of lyssavirus nucleocapsids is low (0.8 ng/ml). With a panel of 1030 specimens received for rabies diagnostic testing, this test was found to be highly specific (0.999) and sensitive (0.970) when compared to other recommended rabies diagnostic methods.

  8. Library of monoclonal antibodies against brush border membrane epithelial antigens

    International Nuclear Information System (INIS)

    Behar, M.; Katz, A.; Silverman, M.

    1986-01-01

    A purified fraction of proximal tubule brush border membranes (BBM) was prepared from dog kidney and used to immunize mice. The standard technique of hybridoma production was followed as described by Kohler and Milstein. Production of antibodies was detected by indirect immunofluorescence on dog kidney slices and by immunodot against the purified fraction on nitrocellulose. Five hybrids exhibited anti BBM activity. These were cloned twice and yielded stable cell lines producing IgG type monoclonal antibodies against BBM. They were designated A 1 , C 7 , D 3 , D 7 and H 4 . As a family these five monoclonals have broad tissue specificity, i.e. positive staining of the surface mucosa of intestinal kidney proximal tubules. D 3 exhibits even broader specificity for epithelium reacting with bile canaliculi and choroid plexus. The authors have verified that at least 4/5 antibodies are directed against BBM protein as revealed by immunoprecipitation of solubilized BBM and detected by Coomassie blue staining or autoradiography of lactoperoxidase labelled BBM. Most interestingly all antibodies bind to the surface of LL CPK 1 cells, a continuous pig kidney cell line of undefined origin but exhibiting many characteristics of proximal tubule cells. The library of monoclonal antibodies obtained provide important probes with which to study membrane biogenesis and polarization in epithelial cells

  9. Effect of implementing anti-HLA antibody detection by Luminex in the kidney transplant program in Chile.

    Science.gov (United States)

    Elgueta, S; Fuentes, C; López, M; Hernández, J; Arenas, A; Jiménez, M; Gajardo, J G; Rodríguez, H; Labraña, C

    2011-11-01

    The development of new highly sensitive, specific technologies to detect HLA antibodies has allowed a better definition of the profile of non-permitted antigens for patients awaiting kidney transplantation. The use of calculated or virtual panel reactive antibodies (CPRA or vPRA) seeks to improve the prediction of positive crossmatches (XM), but increases the proportion of sensitized patients on the waiting list. In 2008-2009, we implemented detection of antibodies using Luminex technology and applied vPRA since 2009. The objective of this study was to evaluate the impact of these innovations in defecting patient sensitization on kidney transplant waiting lists for deceased donors and among transplanted patients. We analyzed the waiting list for 2007 through 2009 and the first semester of 2010, including the patients transplanted in these periods and the XM with deceased donors. We observed an increase in the mean peak PRA of transplanted patients from 7.2% in 2007 to 17.1% in 2010 (P = .001), and in the proportion of patients transplanted with a peak PRA > 50% from 2.8% in 2007 to 15.7% in 2010 (P = .0001), with no increase in the proportion of this population on the waiting lists. There was a concurrent decrease in positive XM among patients with a peak PRA > 50%. The use of vPRA and Luminex permitted a greater number of transplants of patients with peak PRA > 50% and was a good predictor of a positive XM. Published by Elsevier Inc.

  10. Expression of recombinant Antibodies

    Directory of Open Access Journals (Sweden)

    André eFrenzel

    2013-07-01

    Full Text Available Recombinant antibodies are highly specific detection probes in research, diagnostics and have emerged over the last two decades as the fastest growing class of therapeutic proteins. Antibody generation has been dramatically accelerated by in vitro selection systems, particularly phage display. An increasing variety of recombinant production systems have been developed, ranging from Gram-negative and positive bacteria, yeasts and filamentous fungi, insect cell lines, mammalian cells to transgenic plants and animals. Currently, almost all therapeutic antibodies are still produced in mammalian cell lines in order to reduce the risk of immunogenicity due to altered, non-human glycosylation patterns. However, recent developments of glycosylation-engineered yeast, insect cell lines and transgenic plants are promising to obtain antibodies with human-like post-translational modifications. Furthermore, smaller antibody fragments including bispecific antibodies without any glycosylation are successfully produced in bacteria and have advanced to clinical testing. The first therapeutic antibody products from a non-mammalian source can be expected in coming next years. In this review, we focus on current antibody production systems including their usability for different applications.

  11. Uses of monoclonal antibody 8H9

    Science.gov (United States)

    Cheung, Nai-Kong V.

    2013-04-09

    This invention provides a composition comprising an effective amount of monoclonal antibody 8H9 or a derivative thereof and a suitable carrier. This invention provides a pharmaceutical composition comprising an effective amount of monoclonal antibody 8H9 or a derivative thereof and a pharmaceutically acceptable carrier. This invention also provides an antibody other than the monoclonal antibody 8H9 comprising the complementary determining regions of monoclonal antibody 8H9 or a derivative thereof, capable of binding to the same antigen as the monoclonal antibody 8H9. This invention provides a substance capable of competitively inhibiting the binding of monoclonal antibody 8H9. This invention also provides an isolated scFv of monoclonal antibody 8H9 or a derivative thereof. This invention also provides the 8H9 antigen. This invention also provides different uses of the monoclonal antibody 8H9 or its derivative.

  12. Monoclonal anti-human factor VII antibodies. Detection in plasma of a second protein antigenically and genetically related to factor VII.

    OpenAIRE

    Broze, G J; Hickman, S; Miletich, J P

    1985-01-01

    Several murine monoclonal anti-human Factor VII antibodies were produced using hybridoma technology. Two noncompetitive monoclonal antibodies were used to examine by Western blotting the Factor VII cross-reactive material (CRM) in normal human plasma and three commercially available congenitally Factor VII-deficient plasmas, and to construct a facile "sandwich" immunoassay for plasma Factor VII. A second, previously undescribed, form of Factor VII CRM was detected in human plasma, which on We...

  13. Beyond Antibodies as Binding Partners: The Role of Antibody Mimetics in Bioanalysis.

    Science.gov (United States)

    Yu, Xiaowen; Yang, Yu-Ping; Dikici, Emre; Deo, Sapna K; Daunert, Sylvia

    2017-06-12

    The emergence of novel binding proteins or antibody mimetics capable of binding to ligand analytes in a manner analogous to that of the antigen-antibody interaction has spurred increased interest in the biotechnology and bioanalytical communities. The goal is to produce antibody mimetics designed to outperform antibodies with regard to binding affinities, cellular and tumor penetration, large-scale production, and temperature and pH stability. The generation of antibody mimetics with tailored characteristics involves the identification of a naturally occurring protein scaffold as a template that binds to a desired ligand. This scaffold is then engineered to create a superior binder by first creating a library that is then subjected to a series of selection steps. Antibody mimetics have been successfully used in the development of binding assays for the detection of analytes in biological samples, as well as in separation methods, cancer therapy, targeted drug delivery, and in vivo imaging. This review describes recent advances in the field of antibody mimetics and their applications in bioanalytical chemistry, specifically in diagnostics and other analytical methods.

  14. Identification of anti-CD98 antibody mimotopes for inducing antibodies with antitumor activity by mimotope immunization.

    Science.gov (United States)

    Saito, Misa; Kondo, Masahiro; Ohshima, Motohiro; Deguchi, Kazuki; Hayashi, Hideki; Inoue, Kazuyuki; Tsuji, Daiki; Masuko, Takashi; Itoh, Kunihiko

    2014-04-01

    A mimotope is an antibody-epitope-mimicking peptide retrieved from a phage display random peptide library. Immunization with antitumor antibody-derived mimotopes is promising for inducing antitumor immunity in hosts. In this study, we isolated linear and constrained mimotopes from HBJ127, a tumor-suppressing anti-CD98 heavy chain mAb, and determined their abilities for induction of antitumor activity equal to that of the parent antibody. We detected elevated levels of antipeptide responses, but failed to detect reactivity against native CD98-expressing HeLa cells in sera of immunized mice. Phage display panning and selection of mimotope-immunized mouse spleen-derived antibody Fab library showed that HeLa cell-reactive Fabs were successfully retrieved from the library. This finding indicates that native antigen-reactive Fab clones represented an undetectable minor population in mimotope-induced antibody repertoire. Functional and structural analysis of retrieved Fab clones revealed that they were almost identical to the parent antibody. From these results, we confirmed that mimotope immunization was promising for retrieving antitumor antibodies equivalent to the parent antibody, although the co-administration of adjuvant compounds such as T-cell epitope peptides and Toll-like receptor 4 agonist peptides is likely to be necessary for inducing stronger antitumor immunity than mimotope injection alone. © 2014 The Authors. Cancer Science published by Wiley Publishing Asia Pty Ltd on behalf of Japanese Cancer Association.

  15. Evaluation of an antibody avidity index method for detecting recent human immunodeficiency virus type 1 infection using an automated chemiluminescence immunoassay.

    Science.gov (United States)

    Fernández, Gema; Manzardo, Christian; Montoliu, Alexandra; Campbell, Colin; Fernández, Gregorio; Casabona, Jordi; Miró, José Maria; Matas, Lurdes; Rivaya, Belén; González, Victoria

    2015-04-01

    Recent infection testing algorithms (RITAs) are used in public health surveillance to estimate the incidence of recently acquired HIV-1 infection. Our aims were (i) to evaluate the precision of the VITROS® Anti-HIV 1+2 automated antibody avidity assay for qualitative detection of antibodies to HIV 1+2 virus; (ii) to validate the accuracy of an automated guanidine-based antibody avidity assay to discriminate between recent and long standing infections using the VITROS 3600 platform; (iii) to compare this method with BED-CEIA assay; and (iv) to evaluate the occurrence of false recent misclassifications by the VITROS antibody avidity assay in patients with a CD4 count de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  16. Effect of screening for red cell antibodies, other than anti-D, to detect hemolytic disease of the fetus and newborn: a population study in the Netherlands.

    Science.gov (United States)

    Koelewijn, J M; Vrijkotte, T G M; van der Schoot, C E; Bonsel, G J; de Haas, M

    2008-05-01

    Hemolytic disease of the fetus and newborn (HDFN) is a severe disease, resulting from maternal red cell (RBC) alloantibodies directed against fetal RBCs. The effect of a first-trimester antibody screening program on the timely detection of HDFN caused by antibodies other than anti-D was evaluated. Nationwide, all women (1,002 in 305,000 consecutive pregnancies during 18 months) with alloantibodies other than anti-D, detected by a first-trimester antibody screen, were included in a prospective index-cohort study. In a parallel-coverage validation study, patients with HDFN caused by antibodies other than anti-D, that were missed by the screening program, were retrospectively identified. The prevalence of positive antibody screens at first-trimester screening was 1,232 in 100,000; the prevalence of alloantibodies other than anti-D was 328 in 100,000, of which 191 of 100,000 implied a risk for occurrence of HDFN because the father carried the antigen. Overall, severe HDFN, requiring intrauterine or postnatal (exchange) transfusions, occurred in 3.7 percent of fetuses at risk: for anti-K in 11.6 percent; anti-c in 8.5 percent; anti-E in 1.1 percent; Rh antibodies other than anti-c, anti-D, or anti-E in 3.8 percent; and for antibodies other than Rh antibodies or anti-K, in none of the fetuses at risk. All affected children, where antibodies were detected, were promptly treated and healthy at the age of 1 year. The coverage validation study showed a sensitivity of the screening program of 75 percent. Five of 8 missed cases were caused by anti-c, with delay-induced permanent damage in at least 1. First-trimester screening enables timely treatment of HDFN caused by antibodies other than anti-D, however, with a sensitivity of only 75 percent. A second screening at Week 30 of c- women will enhance the screening program. Severe HDFN, caused by antibodies other than anti-D, is associated with anti-K, anti-c, and to a lesser extent with other Rh-alloantibodies.

  17. Development of surface plasmon resonance imaging for detection of Acidovorax avenae subsp. citrulli (Aac) using specific monoclonal antibody.

    Science.gov (United States)

    Puttharugsa, Chokchai; Wangkam, Thidarat; Huangkamhang, Nongluck; Gajanandana, Oraprapai; Himananto, Orawan; Sutapun, Boonsong; Amarit, Ratthasart; Somboonkaew, Armote; Srikhirin, Toemsak

    2011-01-15

    An immunosensor based on surface plasmon resonance imaging (SPR imaging) using a specific monoclonal antibody 11E5 (MAb 11E5) was developed for the detection of the seed-borne bacterium Acidovorax avenae subsp. citrulli (Aac), which causes fruit blotch in watermelons and cantaloupes, and compared to the conventional ELISA technique. The 1:40 mixed self-assembled monolayer (mixed SAM) surface was used for the immobilized MAb 11E5 on sensor surface for the detection of Aac. Both whole cells and broken cells of Aac were tested by using direct and sandwich detection assay. The limit of detection (LOD) of Aac using the SPR imaging technique and a direct detection assay was 10(6)cfu/ml and a subsequent amplification of the SPR signal using a polyclonal antibody (PAb) lowered the LOD to 5×10(5) cfu/ml. The LOD for the ELISA technique was 5×10(4) cfu/ml for the detection of Aac, which was slightly better than that for the SPR technique. However, the sensor surface based on SPR imaging offered a major advantage in terms of surface regeneration, allowing at least five cycles with a shorter time assay, multi-channel analysis with an application on multiplex detection, and an ease of the surface usage for the detection of Aac in the naturally infected plant. The surface was tested against the naturally infected sample and showed good selectivity toward the Aac bacteria. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Porous silicon biosensor for detection of variable domain of heavy-chain of HCAb antibody

    Science.gov (United States)

    Zhang, Hong-yan; Lü, Xiao-yi; Jia, Zhen-hong; Li, Jiang-wei; Zhang, Fu-chun

    2012-03-01

    In this paper, we produce porous silicon (PSi) by electrochemical etching, and it is the first time to evaluate the performance of label-free porous silicon biosensor for detection of variable domain of heavy chain of heavy-chain antibody (VHH). The binding of hen egg white lysozyme (HEWL) and VHH causes a red shift in the reflection spectrum of the biosensor. The red shift is proportional to the VHH concentration in the range from 14 g·ml-1 to 30 g·ml-1 with a detection limit of 0.648 ng·ml-1. The research is useful for the development of label-free biosensor applied in the rapid and sensitive determination of small molecules.

  19. An indirect antibody assay using haptenated antigen and 125I-labelled anti-hapten antibody

    International Nuclear Information System (INIS)

    Aalberse, R.C.; Amsterdam Univ.

    1978-01-01

    Hapten (trinitrophenyl) was coupled to antigen (ovalbumin). The haptenated antigen was bound by anti-ovalbumin antibody and binding was quantitated with 125 I-labelled anti-hapten antibodies. Thus, with a single radioactive reagent, antibodies against a variety of antigens can be detected while the problems inherent in a labelled antiglobulin binding test are avoided. In the ovalbumin system, the haptenated antigen binding test proved to be approximately 20 times as sensitive as the iodinated ovalbumin binding test

  20. Uses of monoclonal antibody 8H9

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Nai-Kong V.

    2018-04-10

    This invention provides a composition comprising an effective amount of monoclonal antibody 8H9 or a derivative thereof and a suitable carrier. This invention provides a pharmaceutical composition comprising an effective amount of monoclonal antibody 8H9 or a derivative thereof and a pharmaceutically acceptable carrier. This invention also provides an antibody other than the monoclonal antibody 8H9 comprising the complementary determining regions of monoclonal antibody 8H9 or a derivative thereof, capable of binding to the same antigen as the monoclonal antibody 8H9. This invention provides a substance capable of competitively inhibiting the binding of monoclonal antibody 8H9. This invention also provides an isolated scFv of monoclonal antibody 8H9 or a derivative thereof. This invention also provides the 8H9 antigen. This invention also provides a method of inhibiting the growth of tumor cells comprising contacting said tumor cells with an appropriate amount of monoclonal antibody 8H9 or a derivative thereof.

  1. Identification of Surface Protein Biomarkers of Listeria monocytogenes via Bioinformatics and Antibody-Based Protein Detection Tools

    Science.gov (United States)

    Zhang, Cathy X. Y.; Brooks, Brian W.; Huang, Hongsheng; Pagotto, Franco

    2016-01-01

    ABSTRACT The Gram-positive bacterium Listeria monocytogenes causes a significant percentage of the fatalities among foodborne illnesses in humans. Surface proteins specifically expressed in a wide range of L. monocytogenes serotypes under selective enrichment culture conditions could serve as potential biomarkers for detection and isolation of this pathogen via antibody-based methods. Our study aimed to identify such biomarkers. Interrogation of the L. monocytogenes serotype 4b strain F2365 genome identified 130 putative or known surface proteins. The homologues of four surface proteins, LMOf2365_0578, LMOf2365_0581, LMOf2365_0639, and LMOf2365_2117, were assessed as biomarkers due to the presence of conserved regions among strains of L. monocytogenes which are variable among other Listeria species. Rabbit polyclonal antibodies against the four recombinant proteins revealed the expression of only LMOf2365_0639 on the surface of serotype 4b strain LI0521 cells despite PCR detection of mRNA transcripts for all four proteins in the organism. Three of 35 monoclonal antibodies (MAbs) to LMOf2365_0639, MAbs M3643, M3644, and M3651, specifically recognized 42 (91.3%) of 46 L. monocytogenes lineage I and II isolates grown in nonselective brain heart infusion medium. While M3644 and M3651 reacted with 14 to 15 (82.4 to 88.2%) of 17 L. monocytogenes lineage I and II isolates, M3643 reacted with 22 (91.7%) of 24 lineage I, II, and III isolates grown in selective enrichment media (UVM1, modified Fraser, Palcam, and UVM2 media). The three MAbs exhibited only weak reactivities (the optical densities at 414 nm were close to the cutoff value) to some other Listeria species grown in selective enrichment media. Collectively, the data indicate the potential of LMOf2365_0639 as a surface biomarker of L. monocytogenes, with the aid of specific MAbs, for pathogen detection, identification, and isolation in clinical, environmental, and food samples. IMPORTANCE L. monocytogenes is

  2. Development and evaluation of a competitive ELISA using a monoclonal antibody for antibody detection after goose parvovirus virus-like particles (VLPs) and vaccine immunization in goose sera.

    Science.gov (United States)

    Wang, Qian; Ju, Huanyu; Li, Yanwei; Jing, Zhiqiang; Guo, Lu; Zhao, Yu; Ma, Bo; Gao, Mingchun; Zhang, Wenlong; Wang, Junwei

    2014-12-01

    An assay protocol based on a monoclonal antibody-based competitive enzyme-linked immunosorbent assay (MAb-based C-ELISA) for detecting antibodies against goose parvovirus (GPV) and its virus-like particles (VLPs) is described. The assay was developed using baculovirus-expressed recombinant VP2 virus-like particles (rVP2-VLPs) as antigens and a monoclonal antibody against GPV as the competitive antibody. Of the four anti-GPV MAbs that were screened, MAb 1G3 was selected as it was blocked by the GPV positive serum. Based on the distribution of percent inhibition (PI) of the known negative sera (n=225), a cut-off value was set at 36% inhibition. Using this cut-off value, the sensitivity of the assay was 93.3% and the specificity was 95.8%, as compared with the gold standard (virus neutralization assay). The rVP2-VLPs did not react with anti-sera to other goose pathogens, indicating that it is specific for the recognization of goose parvovirus antibodies. The assay was then validated with serum samples from goslings vaccinated with several VLPs (rVP1-VLPs, rVP2-VLPs, rVP3-VLPs, and rCGV-VLPs) and other vaccines (inactivated and attenuated). The C-ELISA described in this study is a sensitive and specific diagnostic test and should have wide applications for the sero-diagnosis and immunologic surveillance of GPV. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Detection of Foot-and-mouth Disease Serotype O by ELISA Using a Monoclonal Antibody

    OpenAIRE

    Chen, Hao-tai; Peng, Yun-hua; Zhang, Yong-guang; Liu, Xiang-tao

    2012-01-01

    An ELISA assay with monoclonal antibody (MELISA) was used to type serotype O of foot-and-mouth disease virus (FMDV). All FMDV serotype O reference strains were positive by MELISA, while other viruses such as FMDV serotypes Asia 1, C, and A and classical swine fever virus, swine vesicular disease virus, and porcine reproductive and respiratory syndrome virus remained negative. Furthermore, FMDV serotype O positive samples were able to be detected by MELISA. This assay may be particularly suita...

  4. Patterned immobilization of antibodies within roll-to-roll hot embossed polymeric microfluidic channels.

    Directory of Open Access Journals (Sweden)

    Belachew Feyssa

    Full Text Available This paper describes a method for the patterned immobilization of capture antibodies into a microfluidic platform fabricated by roll-to-roll (R2R hot embossing on poly (methyl methacrylate (PMMA. Covalent attachment of antibodies was achieved by two sequential inkjet printing steps. First, a polyethyleneimine (PEI layer was deposited onto oxygen plasma activated PMMA foil and further cross-linked with glutaraldehyde (GA to provide an amine-reactive aldehyde surface (PEI-GA. This step was followed by a second deposition of antibody by overprinting on the PEI-GA patterned PMMA foil. The PEI polymer ink was first formulated to ensure stable drop formation in inkjet printing and the printed films were characterized using atomic force microscopy (AFM and X-ray photoelectron spectroscopy (XPS. Anti-CRP antibody was patterned on PMMA foil by the developed method and bonded permanently with R2R hot embossed PMMA microchannels by solvent bonding lamination. The functionality of the immobilized antibody inside the microfluidic channel was evaluated by fluorescence-based sandwich immunoassay for detection of C-reactive protein (CRP. The antibody-antigen assay exhibited a good level of linearity over the range of 10 ng/ml to 500 ng/ml (R(2 = 0.991 with a calculated detection limit of 5.2 ng/ml. The developed patterning method is straightforward, rapid and provides a versatile approach for creating multiple protein patterns in a single microfluidic channel for multiplexed immunoassays.

  5. Multiplex serology of paraneoplastic antineuronal antibodies

    NARCIS (Netherlands)

    P. Maat (Peter); E. Brouwer (Eric); E. Hulsenboom (Esther); M.M. van Duijn (Martijn); M.W.J. Schreurs (Marco); H. Hooijkaas (Herbert); P.A. Smitt (Peter)

    2013-01-01

    textabstractParaneoplastic neurological syndromes (PNS) are devastating neurological disorders secondary to cancer, associated with onconeural autoantibodies. Such antibodies are directed against neuronal antigens aberrantly expressed by the tumor. The detection of onconeural antibodies in a patient

  6. Generation of a rabbit single-chain fragment variable (scFv) antibody for specific detection of Bradyrhizobium sp. DOA9 in both free-living and bacteroid forms.

    Science.gov (United States)

    Vu, Nguyen Xuan; Pruksametanan, Natcha; Srila, Witsanu; Yuttavanichakul, Watcharin; Teamtisong, Kamonluck; Teaumroong, Neung; Boonkerd, Nantakorn; Tittabutr, Panlada; Yamabhai, Montarop

    2017-01-01

    A simple and reliable method for the detection of specific nitrogen-fixing bacteria in both free-living and bacteroid forms is essential for the development and application of biofertilizer. Traditionally, a polyclonal antibody generated from an immunized rabbit was used for detection. However, the disadvantages of using a polyclonal antibody include limited supply and cross-reactivity to related bacterial strains. This is the first report on the application of phage display technology for the generation of a rabbit recombinant monoclonal antibody for specific detection and monitoring of nitrogen-fixing bacteria in both free-living form and in plant nodules. Bradyrhizobium sp. DOA9, a broad host range soil bacteria, originally isolated from the root nodules of Aeschynomene americana in Thailand was used as a model in this study. A recombinant single-chain fragment variable (scFv) antibody library was constructed from the spleen of a rabbit immunized with DOA9. After three rounds of biopanning, one specific phage-displayed scFv antibody, designated bDOA9rb8, was identified. Specific binding of this antibody was confirmed by phage enzyme-linked immunosorbent assay (phage ELISA). The phage antibody could bind specifically to DOA9 in both free-living cells (pure culture) and bacteroids inside plant nodules. In addition to phage ELISA, specific and robust immunofluorescence staining of both free-living and bacteroid forms could also be observed by confocal-immunofluorescence imaging, without cross-reactivity with other tested bradyrhizobial strains. Moreover, specific binding of free scFv to DOA9 was also demonstrated by ELISA. This recombinant antibody can also be used for the study of the molecular mechanism of plant-microbe interactions in the future.

  7. Experiments toward the development of a radioimmunoassay for the detection of serum antibodies for the respiratory syncytial virus

    International Nuclear Information System (INIS)

    Heizmann, W.R.

    1982-01-01

    In order to detect an infection by the respiratory syncytial virus (RSV) quickly and safely, a radioimmunassay (RIA) should be developed. Various antigen preparations were compared to one another. The immune serums used in the RIA came from guinea pigs with a RSV antibody titer of up to 320 in the complement binding reaction. A number of observations lead to the discussion of the possibility of the formation (incomplete) of cross-reactive antibodies between virus and host cell. This hypothesis could be well supported through references in the literature. Under the assumption of the existence of cross-reactive antibodies, a further model of the pathogenesis of the RSV illness allows itself to be developed, which could be preceived as an illness with autoimmune components. With this model the varying courses of this disease in different age groups can be easily explained. (orig.) [de

  8. Diagnosis and treatment of antisperm antibody

    Directory of Open Access Journals (Sweden)

    abolreza Kheirollahi

    2011-08-01

    There are several methods to detect ASA. In the past, the clinical interest in ASA was hampered by the fact that a standardized assay for the detection of ASA was lacking. However, it has to be clarified whether each antibody binding to an antigen, which is identified on the sperm surface, also influences sperm function. Several methods have been reported for treatment of immunoinfertility. Most of the available techniques have side effects, are invasive and expensive, have low efficacy, or provide conflicting results.This review article will help to increase our knowledge about diagnosis and treatment methods of ASA.

  9. Transferability of antibody pairs from ELISA to fiber optic surface plasmon resonance for infliximab detection

    Science.gov (United States)

    Van Stappen, Thomas; Lu, Jiadi; Bloemen, Maarten; Geukens, Nick; Spasic, Dragana; Delport, Filip; Verbiest, Thierry; Lammertyn, Jeroen; Gils, Ann

    2015-03-01

    Tumor necrosis factor (TNF)-alpha is a pleiotropic cytokine up-regulated in inflammatory bowel disease, rheumatoid arthritis and psoriasis. The introduction of anti-TNF drugs such as infliximab has revolutionized the treatment of these diseases. Recently, therapeutic drug monitoring (TDM) of infliximab has been introduced in clinical decision making to increase cost-efficiency. Nowadays, TDM is performed using radio-immunoassays, homogeneous mobility shift assays or ELISA. Unfortunately, these assays do not allow for in situ treatment optimization, because of the required sample transportation to centralized laboratories and the subsequent assay execution time. In this perspective, we evaluated the potential of fiber optic-surface plasmon resonance (FO-SPR). To achieve this goal, a panel of 55 monoclonal anti-infliximab antibodies (MA-IFX) was developed and characterized in-house, leading to the identification of nine different clusters. Based on this high diversity, 22 antibody pairs were selected and tested for their reactivity towards IFX, using one MA-IFX as capture and one MA-IFX for detection, in a sandwich type ELISA and FO-SPR. This study showed that the reactivity towards IFX of each antibody pair in ELISA is highly similar to its reactivity on FO-SPR, indicating that antibody pairs are easily transferable between both platforms. Given the fact that FO-SPR shows the potential for miniaturization and fast assay time, it can be considered a highly promising platform for on-site infliximab monitoring.

  10. Detection of thrombocytic antibodies with the direct and indirect haemolysis inhibition test and the radioimmuno-Coombs test

    International Nuclear Information System (INIS)

    Mettenboerger, D.; Vith, E.

    1982-01-01

    Methods of application of the direct and indirect haemolysis inhibition test were studied in order to optimise the test parameters: The ultimate aim was to standardize the test method and compare its sensitivity in detecting various platelet antibodies with platelet indirect radioactive Coombs-test and the platelet immunofluorescence test. (orig.) [de

  11. Immunodiagnostic monoclonal antibody-based sandwich ELISA of fasciolosis by detection of Fasciola gigantica circulating fatty acid binding protein.

    Science.gov (United States)

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-09-01

    Up to now, parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Hence, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. In the present study, a monoclonal antibody (MoAb) against recombinant Fasciola gigantica fatty acid binding protein (rFgFABP) has been produced. As well, a reliable sandwich enzyme-linked immunosorbent assay (sandwich ELISA) has been developed for the detection of circulating FABP in the sera of mice experimentally and cattle naturally infected with F. gigantica. MoAb 3A3 and biotinylated rabbit anti-recombinant FABP antibody were selected due to their high reactivities and specificities. The lower detection limit of sandwich ELISA was 5 pg mL-1, and no cross-reaction with other parasite antigens was observed. This assay could detect F. gigantica infection from day 1 post infection. In experimental mice, the sensitivity, specificity and accuracy of this assay were 93·3, 100 and 98·2%, while in natural cattle they were 96·7, 100 and 99·1%. Hence, this sandwich ELISA method showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica.

  12. Application of 125I-labelled soluble proteins in the histoautoradiographic detection of antigen and antibodies in the spleen of rabbits during primary immune response

    International Nuclear Information System (INIS)

    Rodak, L.

    1975-01-01

    An autoradiographic method for detecting soluble antigen (chicken serum albumin, CSA) and specific antibodies in the spleen of rabbits during a primary immune response is described. The method consists of incubating sections from the spleen with 125 I-labelled IgG 2 anti CSA (for demonstration of antigen) or with 125 I-labelled antigen (for demonstration of specific antibodies). This treatment of histological sections combines the advantages and principles of the immunofluorescence technique with the possibility of evaluating the exact localization of the proteins by light microscopy in preparations stained with haematoxylin or methyl green-pyronin. The sensitivity of detection is very high: both antigen and antibodies could be demonstrated in the spleen follicles for as long as 42 days after the primary intravenous injection

  13. Detection of activated platelets using activation-specific monoclonal antibody (SZ-51) in clinical disorders

    International Nuclear Information System (INIS)

    Wu Guoxin; Li Fugang; Li Jianyong; Ruan Changgeng

    1991-10-01

    A direct test for activated platelets in whole blood was developed by radioimmunoassay with 125 I labeled SZ-51, an antibody specific for an α-granule membrane protein (GMP-140) that associates with the platelet surface during secretion. The assay had sufficient sensitivity to detect as few as 2% activated platelets. In 50 normal subjects, minimal GMP-140 molecules per platelet were expressed on the surface of circulating platelets. Ten patients undergoing cardiopulmonary bypass had transiently increased expression of GMP-140 molecules during the bypass procedure, especially at the end of bypass. Evaluation of 18 patients with epidemic hemorrhagic fever (EHF) has shown that the number of GMP-140 molecules on the platelet surface was closely related to the four different phases of EHF. In six patients suffered from acute myocardial infarction (AMI), the number of GMP-140 molecules changed with the procession of AMI and the highest occurred 48 h after AMI. The GMP-140 molecules were also increased in patients with asthma attack (n = 14), but not in patients with idiopathic thrombocytopenic purpura (n = 11) and diabetic mellitus (n = 48). Taken together, these studies suggest that activated platelet can be reliably measured in whole blood using radiolabeled SZ-51 antibody and the detection of activated platelets is potentially useful in identifying patients with certain thrombotic disorders and others

  14. Monoclonal antibodies for the detection and quantitation of the endogenous plant growth regulator, abscisic acid

    Energy Technology Data Exchange (ETDEWEB)

    Mertens, R.; Weiler, E.W. (Bochum Univ. (Germany, F.R.). Lehrstuhl fuer Pflanzenphysiologie); Deus-Neumann, B. (Muenchen Univ. (Germany, F.R.). Inst. fuer pharmazeutische Biologie)

    1983-08-22

    Monoclonal antibodies (mAB) have been produced which recognize the physiologically active 2-cis-(S)-form of the endogenous plant growth regulator, abscisic acid (ABA). Cross-reaction with the ABA-catabolites, phaseic and dihydrophaseic acid, is negligible, and (R)-ABA, 2-trans-ABA, the ABA-conjugate, ABA-..beta..-D-glucopyranosyl ester, as well as the putative ABA precursor, xanthoxin, are totally unreactive. In addition to being very specific, the mAB exhibit high affinities for 2-cis-(S)-ABA; the K values were 7.9 x 10/sup 9/ l/mol and 3.7 x 10/sup 9/ l/mol for antibodies from two different clones. By mAB-radioimmunoassay (RIA), 4 pg of 2-cis-(S)-ABA (99.5% confidence level) can be detected. mAB-RIA can be used to quantitate ABA directly in unprocessed plant extracts.

  15. Monoclonal antibodies for the detection and quantitation of the endogenous plant growth regulator, abscisic acid

    International Nuclear Information System (INIS)

    Mertens, R.; Weiler, E.W.; Deus-Neumann, B.

    1983-01-01

    Monoclonal antibodies (mAB) have been produced which recognize the physiologically active 2-cis-(S)-form of the endogenous plant growth regulator, abscisic acid (ABA). Cross-reaction with the ABA-catabolites, phaseic and dihydrophaseic acid, is negligible, and (R)-ABA, 2-trans-ABA, the ABA-conjugate, ABA-β-D-glucopyranosyl ester, as well as the putative ABA precursor, xanthoxin, are totally unreactive. In addition to being very specific, the mAB exhibit high affinities for 2-cis-(S)-ABA; the K values were 7.9 x 10 9 l/mol and 3.7 x 10 9 l/mol for antibodies from two different clones. By mAB-radioimmunoassay (RIA), 4 pg of 2-cis-(S)-ABA (99.5% confidence level) can be detected. mAB-RIA can be used to quantitate ABA directly in unprocessed plant extracts. (Auth.)

  16. SINGLE CHAIN VARIABLE FRAGMENTS OF ANTIBODIES AGAINST DIPHTHERIA TOXIN B-SUBUNIT ISOLATED FROM PHAGE DISPLAY HUMAN ANTIBODY LIBRARY

    Directory of Open Access Journals (Sweden)

    Oliinyk O. S.

    2014-02-01

    Full Text Available Diphtheria toxin is an exoantigen of Corynebacterium diphtheriae that inhibits protein synthesis and kills sensitive cells. The aim of this study was to obtain human recombinant single-chain variable fragment (scFv antibodies against receptor-binding B subunit of diphtheria toxin. 12 specific clones were selected after three rounds of a phage display naїve (unimmunized human antibody library against recombinant B-subunit. scFv DNA inserts from these 12 clones were digested with MvaI, and 6 unique restriction patterns were found. Single-chain antibodies were expressed in Escherichia coli XL1-blue. The recombinant proteins were characterized by immunoblotting of bacterial extracts and detection with an anti-E-tag antibody. The toxin B-subunit-binding function of the single-chain antibody was shown by ELISA. The affinity constants for different clones were found to be from 106 to 108 М–1. Due to the fact, that these antibody fragments recognized epitopes in the receptor-binding Bsubunit of diphtheria toxin, further studies are interesting to evaluate their toxin neutralization properties and potential for therapeutic applications. Obtained scFv-antibodies can also be used for detection and investigation of biological properties of diphtheria toxin.

  17. Detection of antibodies to the 20s proteasome by ELISA

    DEFF Research Database (Denmark)

    Jørgensen, Karin Meinike; Frederiksen, Jette Lautrup; Nielsen, Christoffer Tandrup

    2013-01-01

    The presence of antibodies against the 20S proteasome has been correlated with diseases like multiple sclerosis (MS) and systemic lupus erythematosus (SLE) but no definite association has been established. In order to investigate this further, we optimized an ELISA for proteasome antibodies...

  18. Radioimmunoimaging of tumors with a pantumor antibody

    International Nuclear Information System (INIS)

    Chen, D.C.P.; Siegel, M.E.; Chen, F.; Taylor, O.R.; Epstein, A.L.

    1988-01-01

    The TNT-1 antibody was developed to bind intracellular nuclear antigens that are accessible only in degenerative or necrotic cells. Since about 50% of tumor cells are in various stages of cell degeneration or death, this antibody could serve as a pantumor antibody for tumor detection. After intravenous injection of 10 μg of TNT-1F(ab')2 fragments labeled with 20 μCi of I-131, serial images were obtained at 1 and 4 hours and daily for 6 days in mice bearing various human tumors. Accumulation of TNT-1 was imaged in a necrotic tumor as early as 4 hours after injection and because more intense at 48 hours. The tumor-muscle ratio was as high as 29:1. Intense accumulation was noted in the necrotic tumor, about nine times that of healthy tumor. In conclusion, TNT-1, a pantumor antibody, can detect necrotic tumors in animal models. It may be an ideal imaging agent for cancer detection

  19. Duration of antibody response following vaccination against feline immunodeficiency virus.

    Science.gov (United States)

    Westman, Mark E; Malik, Richard; Hall, Evelyn; Harris, Matthew; Hosie, Margaret J; Norris, Jacqueline M

    2017-10-01

    most cats (10/12) by 1 month after the third (final) primary FIV vaccination. All cats tested negative using Witness and Anigen Rapid 6 months after the third primary FIV vaccination. Conclusions and relevance This study has shown that a primary course of FIV vaccination does not interfere with FIV antibody testing in cats using Witness and Anigen Rapid, provided primary vaccination has not occurred within the previous 6 months. Consequently, Witness and Anigen Rapid antibody test kits can be used reliably to determine FIV infection status at the time of annual booster FIV vaccination to help detect 'vaccine breakthroughs' and in cats that have not received a primary course of FIV vaccination within the preceding 6 months. The duration of antibody response following annual booster FIV vaccination and the resulting effect on antibody testing using PoC kits needs to be determined by further research. The mechanism(s) for the variation in FIV antibody test kit performance remains unclear.

  20. Detection of Schistosoma Antibodies and exploration of associated factors among local residents around Inlay Lake, Southern Shan State, Myanmar.

    Science.gov (United States)

    Soe, Htin Zaw; Oo, Cho Cho; Myat, Tin Ohn; Maung, Nay Soe

    2017-03-01

    Schistosomiasis is a chronic parasitic disease caused by blood flukes (trematode worms) of the genus Schistosoma. Its transmission has been reported in 78 countries affecting at least 258 million people world-wide. It was documented that S. japonicum species was prevalent in Shan State, Myanmar, but the serological study was not conducted yet. General objective of the present study was to detect schistosoma antibodies and explore associated factors among local residents living around Inlay Lake, Nyaung Shwe Township, and Southern Shan State, Myanmar. An exploratory and cross-sectional analytic study was conducted among local residents (n = 315) in selected rural health center (RHC) areas from December 2012 through June 2013. The participants were interviewed with pretested semi-structured questionnaires and their blood samples (serum) were tested using Schistosomiasis Serology Microwell ELISA test kits (sensitivity 100% and specificity 85%) which detected IgG antibodies but could not distinguish between a new and past infection. Data collected were analysed by SPSS software 16.0 and associations of variables were determined by Chi-squared test with a significant level set at 0.05. Schistosoma seroprevalence (IgG) in study area was found to be 23.8% (95% CI: 18.8-28.8%). The present study is the first and foremost study producing serological evidence of schistosoma infection-one of the neglected tropical diseases-in local people of Myanmar. The factors significantly associated with seropositivity were being male [OR = 2.6 (95% CI: 1.5-4.49), P Myanmar, and this should be further confirmed parasitologically and kept under surveillance. Proper trainings on diagnosis, treatment, prevention and control of schistosomiasis should be provided to the healthcare providers. ISRCTN ISRCTN73824458 . Registered 28 September 2014, retrospectively registered.

  1. Prevalence of Antibodies Against Hepatitis e Virus in Veterinarians in Estonia

    DEFF Research Database (Denmark)

    Lassen, Brian; Janson, Marilin; Neare, Kädi

    2017-01-01

    positive with both tests. Antibody-positive samples were further examined for the presence of HEV RNA. Three (2.6%) of the 115 veterinarians tested positive for immunoglobulin G antibodies against HEV, whereas no immunoglobulin M antibodies against the virus were detected. The antibody......-positive veterinarians were small animal practitioners. Pigs comprised no or small part of their working time or patients. No HEV RNA was detected in the antibody-positive samples. The prevalence of antibodies against HEV in veterinarians in Estonia was lower than what has been observed in veterinarians in other...

  2. Detection of antibodies against Paracoccidioides brasiliensis melanin in in vitro and in vivo studies during infection.

    Science.gov (United States)

    Urán, Martha E; Nosanchuk, Joshua D; Restrepo, Angela; Hamilton, Andrew J; Gómez, Beatriz L; Cano, Luz E

    2011-10-01

    Several cell wall constituents, including melanins or melanin-like compounds, have been implicated in the pathogenesis of a wide variety of microbial diseases caused by diverse species of pathogenic bacteria, fungi, and helminthes. Among these microorganisms, the dimorphic fungal pathogen Paracoccidioides brasiliensis produces melanin in its conidial and yeast forms. In the present study, melanin particles from P. brasiliensis were injected into BALB/c mice in order to produce monoclonal antibodies (MAbs). We identified five immunoglobulin G1 (IgG1) κ-chain and four IgM melanin-binding MAbs. The five IgG1 κ-chain isotypes are the first melanin-binding IgG MAbs ever reported. The nine MAbs labeled P. brasiliensis conidia and yeast cells both in vitro and in pulmonary tissues. The MAbs cross-reacted with melanin-like purified particles from other fungi and also with commercial melanins, such as synthetic and Sepia officinalis melanin. Melanization during paracoccidioidomycosis (PCM) was also further supported by the detection of IgG antibodies reactive to melanin from P. brasiliensis conidia and yeast in sera and bronchoalveolar lavage fluids from P. brasiliensis-infected mice, as well as in sera from human patients with PCM. Serum specimens from patients with other mycoses were also tested for melanin-binding antibodies by enzyme-linked immunosorbent assay, and cross-reactivities were detected for melanin particles from different fungal sources. These results suggest that melanin from P. brasiliensis is an immunologically active fungal structure that activates a strong IgG humoral response in humans and mice.

  3. Intramuscular Adeno-Associated Virus-Mediated Expression of Monoclonal Antibodies Provides 100% Protection Against Ebola Virus Infection in Mice.

    Science.gov (United States)

    van Lieshout, Laura P; Soule, Geoff; Sorensen, Debra; Frost, Kathy L; He, Shihua; Tierney, Kevin; Safronetz, David; Booth, Stephanie A; Kobinger, Gary P; Qiu, Xiangguo; Wootton, Sarah K

    2018-03-05

    The 2013-2016 West Africa outbreak demonstrated the epidemic potential of Ebola virus and highlighted the need for counter strategies. Monoclonal antibody (mAb)-based therapies hold promise as treatment options for Ebola virus infections. However, production of clinical-grade mAbs is labor intensive, and immunity is short lived. Conversely, adeno-associated virus (AAV)-mediated mAb gene transfer provides the host with a genetic blueprint to manufacture mAbs in vivo, leading to steady release of antibody over many months. Here we demonstrate that AAV-mediated expression of nonneutralizing mAb 5D2 or 7C9 confers 100% protection against mouse-adapted Ebola virus infection, while neutralizing mAb 2G4 was 83% protective. A 2-component cocktail, AAV-2G4/AAV-5D2, provided complete protection when administered 7 days prior to challenge and was partially protective with a 3-day lead time. Finally, AAV-mAb therapies provided sustained protection from challenge 5 months following AAV administration. AAV-mAb may be a viable alternative strategy for vaccination against emerging infectious diseases.

  4. A flow cytometry-based workflow for detection and quantification of anti-plasmodial antibodies in vaccinated and naturally exposed individuals

    DEFF Research Database (Denmark)

    Ajua, Anthony; Engleitner, Thomas; Esen, Meral

    2012-01-01

    information about natural exposure and vaccine immunogenicity. A novel, cytometry-based workflow for the quantitative detection of anti-plasmodial antibodies in human serum is presented. METHODS: Fixed red blood cells (RBCs), infected with late stages of P. falciparum were utilized to detect malaria...... vaccine trials in semiimmune adults and pre-school children residing in a malaria endemic area. RESULTS: Fixation, permeabilization, and staining of infected RBCs were adapted for best operation in flow cytometry. As asexual vaccine candidates are designed to induce antibody patterns similar to semi...... with those obtained by manual gating (r between 0.79 and 0.99) and outperformed other model-driven gating methods. Bland-Altman plots confirmed the agreement of manual gating and OSA derived results. A-1.33 fold increase (p=0.003) in the number of positive cells after vaccination in a subgroup of preschool...

  5. SGLT2 inhibitors provide an effective therapeutic option for diabetes complicated with insulin antibodies.

    Science.gov (United States)

    Hayashi, Akinori; Takano, Koji; Kawai, Sayuki; Shichiri, Masayoshi

    2016-01-01

    Diabetes mellitus complicated with insulin antibodies is rare in clinical practice but usually difficult to control. A high amount of insulin antibodies, especially with low affinity and high binding capacity, leads to unstable glycemic control characterized by hyperglycemia unresponsive to large volume of insulin and unanticipated hypoglycemia. There are several treatment options, such as changing insulin preparation, immunosupression with glucocorticoids, and plasmapheresis, most of which are of limited efficacy. Sodium-glucose cotransporter 2 (SGLT2) inhibitors are a novel class of drug which decrease renal glucose reabsorption and lowers plasma glucose level independent of insulin action. We report here a case with diabetes complicated with insulin antibodies who was effectively controlled by an SGLT2 inhibitor. A 47-year-old man with type 2 diabetes treated with insulin had very poor glycemic control characterized by postprandial hyperglycemia unresponsive to insulin therapy and repetitive hypoglycemia due to insulin antibodies. Treatment with ipragliflozin, an SGLT2 inhibitor, improved HbA1c from 8.4% to 6.0% and glycated albumin from 29.4% to 17.9%. Continuous glucose monitoring revealed improvement of glycemic profile (average glucose level from 212 mg/dL to 99 mg/dL and glycemic standard deviation from 92 mg/dL to 14 mg/dL) with disappearance of hypoglycemic events. This treatment further ameliorated the characteristics of insulin antibodies and resulted in reduced insulin requirement. SGLT2 inhibitors may offer an effective treatment option for managing the poor glycemic control in diabetes complicated with insulin antibodies.

  6. Detection of autoimmune antibodies in localized scleroderma by synthetic oligonucleotide antigens

    DEFF Research Database (Denmark)

    Samuelsen, Simone; Jørgensen, Christian Damsgaard; Mellins, Elizabeth D

    2018-01-01

    In this study, we developed a series of synthetic oligonucleotides that allowed us to investigate the details on the antigen recognition by autoimmune antibodies in localized scleroderma subjects. Besides dramatically improved analytical specificity of the assay, our data suggests a potential...... linking for antibodies to DNA to the biological status of disease state in localized scleroderma. Moreover, introducing chemical modifications into short synthetic deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) molecules completely changed the binding titers of corresponding antibodies...... and their clinical relevance. The strongest observed effect was registered for the localized scleroderma skin damage index (LoSDI) on the IgG antibodies to TC dinucleotide-rich double-stranded antigen (p

  7. Generation and characterization of a human-mouse chimeric high-affinity antibody that detects the DYKDDDDK FLAG peptide.

    Science.gov (United States)

    Ikeda, Koki; Koga, Tomoaki; Sasaki, Fumiyuki; Ueno, Ayumi; Saeki, Kazuko; Okuno, Toshiaki; Yokomizo, Takehiko

    2017-05-13

    DYKDDDDK peptide (FLAG) is a useful tool for investigating the function and localization of proteins whose antibodies (Abs) are not available. We recently established a high-affinity monoclonal antibody (mAb) for FLAG (clone 2H8). The 2H8 Ab is highly sensitive for detecting FLAG-tagged proteins by flowcytometry and immunoprecipitation, but it can yield nonspecific signals in immunohistochemistry of mouse tissues because it is of mouse origin. In this study, we reduced nonspecific signals by generating a chimeric 2H8 Ab with Fc fragments derived from human immunoglobulin. We fused a 5' terminal cDNA fragments for the Fab region of 2H8 mAb with 3' terminal cDNA fragments for Fc region of human IgG1. We transfected both chimeric plasmids and purified the resulting human-mouse chimeric 2H8. The chimeric 2H8 Ab successfully detected FLAG-tagged proteins in flowcytometry with anti-human IgG secondary Ab with comparable sensitivity to 2H8 mAb. Importantly, chimeric 2H8 detected specific FLAG peptide signals without nonspecific signals in immunohistochemical analysis with mouse tissues. This human-mouse chimeric high-affinity anti-FLAG Ab will prove useful for future immunohistochemical analysis of mouse tissues. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Multiplex serology of paraneoplastic antineuronal antibodies.

    Science.gov (United States)

    Maat, Peter; Brouwer, Eric; Hulsenboom, Esther; VanDuijn, Martijn; Schreurs, Marco W J; Hooijkaas, Herbert; Smitt, Peter A E Sillevis

    2013-05-31

    Paraneoplastic neurological syndromes (PNS) are devastating neurological disorders secondary to cancer, associated with onconeural autoantibodies. Such antibodies are directed against neuronal antigens aberrantly expressed by the tumor. The detection of onconeural antibodies in a patient is extremely important in diagnosing a neurological syndrome as paraneoplastic (70% is not yet known to have cancer) and in directing the search for the underlying neoplasm. At present six onconeural antibodies are considered 'well characterized' and recognize the antigens HuD, CDR62 (Yo), amphiphysin, CRMP-5 (CV2), NOVA-1 (Ri), and Ma2. The gold standard of detection is the characteristic immunohistochemical staining pattern on brain tissue sections combined with confirmation by immunoblotting using recombinant purified proteins. Since all six onconeural antibodies are usually analyzed simultaneously and objective cut-off values for these analyses are warranted, we developed a multiplex assay based on Luminex technology. Reaction of serial dilutions of six onconeural standard sera with microsphere-bound antigens showed lower limits of detection than with Western blotting. Using the six standard sera at a dilution of 1:200, the average within-run coefficient of variation (CV) was 4% (range 1.9-7.3%). The average between-run within-day CV was 5.1% (range 2.9-6.7%) while the average between-day CV was 8.1% (range 2.8-11.6%). The shelf-life of the antigen coupled microspheres was at least two months. The sensitivity of the multiplex assay ranged from 83% (Ri) to 100% (Yo, amphiphysin, CV2) and the specificity from 96% (CV2) to 100% (Ri). In conclusion, Luminex-based multiplex serology is highly reproducible with high sensitivity and specificity for the detection of onconeural antibodies. Conventional immunoblotting for diagnosis of onconeural antibodies in the setting of a routine laboratory may be replaced by this novel, robust technology. Copyright © 2013 Elsevier B.V. All rights

  9. Pistachio (Pistacia vera L.) Detection and Quantification Using a Murine Monoclonal Antibody-Based Direct Sandwich Enzyme-Linked Immunosorbent Assay.

    Science.gov (United States)

    Liu, Changqi; Chhabra, Guneet S; Sathe, Shridhar K

    2015-10-21

    A commercially available direct sandwich enzyme-linked immunosorbent assay (ELISA) (BioFront Technologies, Tallahassee, FL, USA) using murine anti-pistachio monoclonal antibodies (mAbs) as capture and detection antibodies was evaluated. The assay was sensitive (limit of detection = 0.09 ± 0.02 ppm full fat pistachio, linear detection range = 0.5-36 ppm, 50% maximum signal concentration = 7.9 ± 0.7 ppm), reproducible (intra- and inter-assay variability pistachio seeds subjected to autoclaving (121 °C, 15 psi, 15, 30 min), blanching (100 °C, 5, 10 min), frying (191 °C, 1 min), microwaving (500, 1000 W, 3 min), and dry roasting (140 °C, 30 min; 168 °C, 12 min). No cross-reactivity was observed in 156 food matrices, each tested at 100,000 ppm, suggesting the ELISA to be pistachio specific. The pistachio recovery ranges for spiked (10 ppm) and incurred (10-50000 ppm) food matrices were 93.1-125.6% and 35.7-112.2%, respectively. The assay did not register any false-positive or -negative results among the tested commercial and laboratory prepared samples.

  10. Lack of antibodies to NMDAR or VGKC-complex in GAD and cardiolipin antibody-positive refractory epilepsy.

    Science.gov (United States)

    Liimatainen, Suvi; Peltola, Jukka; Hietaharju, Aki; Sabater, Lidia; Lang, Bethan

    2014-03-01

    Over the last few years autoantibodies against neuronal proteins have been identified in several forms of autoimmune encephalitis and epilepsy. NMDA receptor (NMDAR) and voltage gated potassium channel (VGKC) complex antibodies are mainly associated with limbic encephalitis (LE) whereas glutamic acid decarboxylase antibodies (GADA) and anticardiolipin (ACL) antibodies are more commonly detected in patients with chronic epilepsy. Clinical features vary between these antibodies suggesting the specificity of different neuronal antibodies in seizures. Serum samples of 14 GADA positive and 24 ACL positive patients with refractory epilepsy were analyzed for the presence of VGKC or NMDAR antibodies. No positive VGKC or NMDAR antibodies were found in these patients. The results confirm the different significance of these neuronal antibodies in seizure disorders. Different autoantibodies have different significance in seizures and probably have different pathophysiological mechanisms of actions. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Production and characterization of monoclonal antibodies specific to the strobilurin pesticide pyraclostrobin.

    Science.gov (United States)

    Mercader, Josep V; Suárez-Pantaleón, Celia; Agulló, Consuelo; Abad-Somovilla, Antonio; Abad-Fuentes, Antonio

    2008-09-10

    Strobilurin fungicides are nowadays among the most important fungicides in the market of active agrochemicals. Pyraclostrobin, which belongs to the last generation of this family of molecules, shows a broader antifungal activity spectrum and higher efficiency and security profiles than previous fungicides. This paper describes the synthesis of functionalized haptens, the production of monoclonal antibodies, and the development of enzyme-linked immunosorbent assays (ELISA) for the detection of pyraclostrobin. A conformational analysis of hapten structure was performed, which provided relevant data concerning the length of the spacer arm. A very useful strategy has been followed for the screening of hybridomas, leading to the selection of a panel of high-affinity monoclonal antibodies to pyraclostrobin. Moreover, different immunoassays have been characterized using the conjugate-coated indirect ELISA format, and limits of detection below 0.1 microg/L have been obtained. Also, a simplified one-step procedure has been carried out with two indirect assays. Finally, these results have been compared with the performance of the same antibodies in the antibody-coated direct ELISA format.

  12. Immunogenicity of anti-tumor necrosis factor antibodies-toward improved methods of anti-antibody measurement.

    Science.gov (United States)

    Aarden, Lucien; Ruuls, Sigrid R; Wolbink, Gertjan

    2008-08-01

    To date, millions of people have been treated with therapeutic monoclonal antibodies (TmAbs) for various indications. It is becoming increasingly clear that TmAbs can be immunogenic, which may reduce efficacy or induce adverse effects. Over the years, the importance of antibody formation has been questioned and sometimes minimized, as few antibody responses to TmAbs (HACA or HAHA) were reported. However, the methods to detect and quantify such antibodies used in the past have been problematic. Only recently, methods have been developed that have adequate sensitivity and are not seriously disturbed by false-positive reactions caused by rheumatoid factors, natural antibodies to Fab or F(ab')2 fragments, or Fc interactions of IgG4. The large number of treated patients, in combination with these new assays, presents a unique opportunity to study the anti-antibody immune response in man, possibly allowing us to manipulate immunogenicity in the future.

  13. Validation of pre-coated ELISA tests to detect antibodies against T. congolense and T. vivax

    International Nuclear Information System (INIS)

    Shumba, W.

    2000-01-01

    The anti-trypanosomal antibody detecting enzyme linked immunosorbent assay (ELISA) was first described in 1977 and was further developed for use in large scale surveys in Zimbabwe. More recently, the IAEA initiated a programme to improve the robustness and standardisation of the assay. The IAEA supplied plates pre-coated with either a crude T. congolense or T. vivax antigen and the reagents necessary for analysing samples. Parasitologically positive and negative sera were used to validate and determine the cut-off values of the two tests. The samples were tested and results analysed using a variety of cut-off values. The tests provided similar information although the T. congolense pre-coated plates gave significantly higher optical density values than the plates coated with T. vivax. Sensitivity and specificity values were calculated using the different cut-off points. Results indicate that the test using T. congolense antigen had the highest specificity and sensitivity for a given cut-off value. Although the test could distinguish positive from negative sera, it was quite difficult to provide a suitable cut-off value, but the value should be dictated by the use of the test. (author)

  14. Monoclonal antibody against Porphyromonas (Bacteroides) endodontalis lipopolysaccharide and application of the antibody for direct identification of the species.

    OpenAIRE

    Hanazawa, S; Sagiya, T; Kitami, H; Ohta, K; Nishikawa, H; Kitano, S

    1991-01-01

    The aim of the present study was to develop a monoclonal antibody that recognizes the shared antigen of Porphyromonas endodontalis so that we could use the antibody in direct identification and detection of P. endodontalis in infectious material from apical periodontal patients. We established a hybridoma cell line producing monoclonal antibody (BEB5) specific for P. endodontalis. BEB5 antibody reacted with all of the P. endodontalis strains tested, but not with any of the other black-pigment...

  15. Detection of hepatitis C virus (HCV among health care providers in an Egyptian university hospital: different diagnostic modalities

    Directory of Open Access Journals (Sweden)

    El-Sokkary RH

    2017-10-01

    Full Text Available Rehab H El-Sokkary,1 Rehab M Elsaid Tash,1 Takwa E Meawed,1 Omnia S El Seifi,2 Eman M Mortada2 1Medical Microbiology and Immunology Department, 2Community, Environmental and Occupational Medicine Department, Faculty of Medicine, Zagazig University, Zagazig, Egypt Background: Hepatitis C virus (HCV infection has received much attention and is placed at the core of the infection control agenda. It is considered as a major public health problem in Egypt, where the highest prevalence of HCV exists. The great risk of exposure to infection of health care providers (HCPs has highlighted the urgent need for implementing an infection control program. Objective: The purpose of this study was to detect the prevalence of HCV infection among HCPs in Zagazig University Hospitals and to assess the performance of different diagnostic modalities.Methodology: Blood, polymerase chain reaction (PCR, enzyme-linked immunosorbent assay (ELISA, and saliva tests were performed in enrolled HCPs.Results: This study compared HCV diagnosis Hepanostika HCV Ultra ELISA as a screening test and PCR as gold standard test, which resulted in 40.6% positive results by ELISA compared to 34.8% by PCR (p<0.0001, while OraQuick HCV rapid antibody compared to PCR shows that 37.7% of the participants were positive by OraQuick HCV rapid antibody test. Application of standard precautions while dealing with blood has negative significant correlation with HCV infection (rs=–0.265, p=0.03.Conclusion: HCPs at Zagazig University Hospitals are at high risk for HCV infection. Lack of compliance and awareness of prevention and control of the infection are associated cofactors. Serum HCV-Ab detection by Hepanostika HCV Ultra ELISA and OraQuick HCV rapid antibody test are sensitive and specific serologic assays for diagnosis with correspondent results to that obtained by quantitative real-time PCR. Keywords: HCV, ROC curve, OraQuick HCV, infection control

  16. Chimeric anti-staphylococcal enterotoxin B antibodies and lovastatin act synergistically to provide in vivo protection against lethal doses of SEB.

    Directory of Open Access Journals (Sweden)

    Mulualem E Tilahun

    Full Text Available Staphylococcal enterotoxin B (SEB is one of a family of toxins secreted by Staphylococcus aureus that act as superantigens, activating a large fraction of the T-cell population and inducing production of high levels of inflammatory cytokines that can cause toxic shock syndrome (TSS and death. Extracellular engagement of the TCR of T-cells and class II MHC of antigen presenting cells by SEB triggers the activation of many intracellular signaling processes. We engineered chimeric antibodies to block the extracellular engagement of cellular receptors by SEB and used a statin to inhibit intracellular signaling. Chimeric human-mouse antibodies directed against different neutralizing epitopes of SEB synergistically inhibited its activation of human T-cells in vitro. In the in vivo model of lethal toxic shock syndrome (TSS in HLA-DR3 transgenic mice, two of these antibodies conferred significant partial protection when administered individually, but offered complete protection in a synergistic manner when given together. Similarly, in vivo, lovastatin alone conferred only partial protection from TSS similar to single anti-SEB antibodies. However, used in combination with one chimeric neutralizing anti-SEB antibody, lovastatin provided complete protection against lethal TSS in HLA-DR3 transgenic mice. These experiments demonstrate that in vivo protection against lethal doses of SEB can be achieved by a statin of proven clinical safety and chimeric human-mouse antibodies, agents now widely used and known to be of low immunogenicity in human hosts.

  17. Potential radioimmunoassay system for detection of Hanganutziu-Deicher type heterophile antigen(s) and antibodies in tissues and fluids

    Energy Technology Data Exchange (ETDEWEB)

    Mukuria, J C; Naiki, Masaharu; Hashimoto, Masato; Nishiura, Katsumi; Okabe, Masahiro; Kato, Shiro

    1985-06-12

    A relatively simple, specific and sensitive radioimmunoassay system has been developed for the detection of heterophile Hanganutziu-Deicher (H-D) antigen(s) and antibodies. The SVI-labeled H-D antigen-active molecule used for the assay is a bovine erythrocyte major glycoprotein previously found to have a strong H-D antigen potency. Different H-D antigen-active molecules were compared for heterophile H-D antigen potency. Eight different lung cancer tissues were assayed for H-D antigen. The sera from the 8 lung cancer patients were also screened by ELISA and RIA in an attmept to correlate expression of H-D antigen on tissues with elevation of H-D antibodies.

  18. Simultaneous measurements of auto-immune and infectious disease specific antibodies using a high throughput multiplexing tool.

    Directory of Open Access Journals (Sweden)

    Atul Asati

    Full Text Available Considering importance of ganglioside antibodies as biomarkers in various immune-mediated neuropathies and neurological disorders, we developed a high throughput multiplexing tool for the assessment of gangliosides-specific antibodies based on Biolpex/Luminex platform. In this report, we demonstrate that the ganglioside high throughput multiplexing tool is robust, highly specific and demonstrating ∼100-fold higher concentration sensitivity for IgG detection than ELISA. In addition to the ganglioside-coated array, the high throughput multiplexing tool contains beads coated with influenza hemagglutinins derived from H1N1 A/Brisbane/59/07 and H1N1 A/California/07/09 strains. Influenza beads provided an added advantage of simultaneous detection of ganglioside- and influenza-specific antibodies, a capacity important for the assay of both infectious antigen-specific and autoimmune antibodies following vaccination or disease. Taken together, these results support the potential adoption of the ganglioside high throughput multiplexing tool for measuring ganglioside antibodies in various neuropathic and neurological disorders.

  19. Detection of experimental thrombi in rabbits with an 131I-labelled fibrin-specific monoclonal antibody

    International Nuclear Information System (INIS)

    Walker, K.Z.; Milner, L.J.; Boniface, G.R.

    1990-01-01

    The detection of thrombi in rabbits has been investigated with 131 I-labelled DD-3B6/22, a monoclonal antibody (Mab) reactive at high affinity (Kd=2.68x10 -10 M) with human D Dimer (DD). DD-3B6/22 bound well to both 'fresh' and 'aged' human clots in an in vitro assay but showed poor binding to rabbit clots. However, reactivity was restored to rabbit blood if it was seeded, before clotting, with human DD covalently coupled to Sepharose beads. Thus, a rabbit model was developed in which blood was allowed to clot around DD-Sepharose beads introduced into the jugular vein. Gamma camera imaging showed that intact 131 I-labelled DD-3B6/22 localised to these clots within 24 h. Uptake at this time was 0.202%±0.012% injected dose per gram (%ID/g) compared with 0.086±0.018%ID/g after injection of control antibody. 131 I-labelled F(ab') 2 fragments of DD-3B6/22 allowed earlier scintigraphic detection of the clot which was evident 4 h after injection. Uptake in the clot at 24 h was 0.154±0.038% ID/g compared with 0.109±0.027% ID/g for a control F(ab') 2 . As antigen levels in the clot are estimated to be less than 300 μg DD, thus representing a very small human clot, the DD-3B6/22 Mab would appear to have a good potential for the sensitive detection of thrombi in a clinical setting. (orig.)

  20. Serum transglutaminase 3 antibodies correlate with age at celiac disease diagnosis.

    Science.gov (United States)

    Salmi, Teea T; Kurppa, Kalle; Hervonen, Kaisa; Laurila, Kaija; Collin, Pekka; Huhtala, Heini; Saavalainen, Päivi; Sievänen, Harri; Reunala, Timo; Kaukinen, Katri

    2016-06-01

    Transglutaminase (TG)2 is the autoantigen in celiac disease, but also TG3 antibodies have been detected in the serum of celiac disease patients. To investigate the correlations between serum TG3 antibodies and clinical and histological manifestations of celiac disease and to assess gluten-dependency of TG3 antibodies. Correlations between serum TG3 antibody levels measured from 119 adults and children with untreated coeliac disease and the demographic data, clinical symptoms, celiac antibodies, histological data and results of laboratory tests and bone mineral densities were tested. TG3 antibodies were reinvestigated in 97 celiac disease patients after 12 months on a gluten-free diet (GFD). TG3 antibody titers were shown to correlate with the age at celiac disease diagnosis. Further, negative correlation with TG3 antibodies and intestinal γδ+ cells at diagnosis and on GFD was detected. Correlations were not detected with the clinical manifestation of celiac disease, TG2 or endomysial autoantibodies, laboratory values, severity of mucosal villous atrophy, associated diseases or complications. TG3 antibody titers decreased on GFD in 56% of the TG3 antibody positive patients. Serum TG3 antibody positivity in celiac disease increases as the diagnostic age rises. TG3 antibodies did not show similar gluten-dependency as TG2 antibodies. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  1. Immunochemical characteristics of IgG4 antibodies

    NARCIS (Netherlands)

    van der Zee, J. S.; Aalberse, R. C.

    1988-01-01

    Although a small part of the IgG4 subclass probably can bind to basophils (and mast cells), IgG4 antibodies usually do not behave as anaphylactic antibodies. Therefore, detection of IgG4 antibodies in serum is not a suitable in vitro assay for IgG-S-TS activity. Furthermore, differences between IgG4

  2. A novel monoclonal antibody for detection of galectin-9 in tissue sections: application to human tissues infected by oncogenic viruses

    Directory of Open Access Journals (Sweden)

    Barjon Clément

    2012-07-01

    Full Text Available Abstract Background Galectin-9 is a mammalian lectin which possesses immunosuppressive properties. Excessive production of galectin-9 has been reported in two types of human virus-associated diseases chronic hepatitis C and nasopharyngeal carcinoma associated to the Epstein-Barr virus. The objective of this study was to produce new monoclonal antibodies targeting galectin-9 in order to improve its detection in clinical samples, especially on tissue sections analysed by immunohistochemistry. Methods Hybridomas were produced through immunization of mice with the recombinant c-terminus part of galectin-9 (residues 191 to 355 of the long isoform and semi-solid fusion of spleen cells with Sp2/0 cells. Monoclonal antibodies were characterized using ELISA, epitope mapping, western blot and immunohistochemistry. Results We selected seven hybridomas producing antibodies reacting with our recombinant c-terminus galectin-9 in ELISA. Five of them reacted with the epitope “TPAIPPMMYPHPA” (common to all isoforms, residues 210 to 222 of the long isoform and stained all three isoforms of galectin-9 analysed by western blot. One of them, 1G3,demonstrated very good sensitivity and specificity when used for immunohistochemistry. Using 1G3, we could confirm the intense and constant expression of galectin-9 by Epstein-Barr virus positive malignant cells from nasopharyngeal carcinomas. In most samples, specific staining was detected in both cytoplasm and nuclei. Galectin-9 was also detected in liver biopsies from patients infected by the human hepatitis C or B viruses with expression not only in inflammatory leucocytes and Kupffer cells, but also in hepatocytes. In contrast, galectin-9 was virtually absent in non-infected liver specimens. Conclusion The 1G3 monoclonal antibody will be a powerful tool to assess galectin-9 expression and distribution especially in diseases related to oncogenic viruses.

  3. Solid-phase radioimmunoassay for the detection fo IgG antibodies to gramineae pollen (Dactylis glomerata) and to acarida (dermatophagoides Pteronyssinus)

    Energy Technology Data Exchange (ETDEWEB)

    Guilloux, L.; Ville, G.

    1985-01-01

    A solid-phase radioimmunoassay using SVI-protein A onto polystyrene microplates, was applied successfully for the detection of IgG antibodies to acarida and to grass pollen in allergic patients and in patients undergoing desensitization therapy.

  4. Characterization of immobilization methods of antiviral antibodies in serum for electrochemical biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Huy, Tran Quang, E-mail: huytq@nihe.org.vn [National Institute of Hygiene and Epidemiology (NIHE), No1 Yersin St., Hanoi (Viet Nam); International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology (HUST), No1 Dai Co Viet, Hanoi (Viet Nam); Hanh, Nguyen Thi Hong; Van Chung, Pham; Anh, Dang Duc; Nga, Phan Thi [National Institute of Hygiene and Epidemiology (NIHE), No1 Yersin St., Hanoi (Viet Nam); Tuan, Mai Anh, E-mail: tuanma-itims@mail.hut.edu.vn [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology (HUST), No1 Dai Co Viet, Hanoi (Viet Nam)

    2011-06-01

    In this paper, we describes different methods to immobilize Japanese encephalitis virus (JEV) antibodies in human serum onto the interdigitated surface of a microelectrode sensor for optimizing electrochemical detection: (1) direct covalent binding to the silanized surface, (2) binding to the silanized surface via a cross-linker of glutaraldehyde (GA), (3) binding to glutaraldehyde/silanized surface via goat anti-human IgG polyclonal antibody and (4) binding to glutaraldehyde/silanized surface via protein A (PrA). Field emission scanning electron microscopy, Fourier transform infrared spectrometry, and fluorescence microscopy are used to verify the characteristics of antibodies on the interdigitated surface after the serum antibodies immobilization. The analyzed results indicate that the use of protein A is an effective choice for immobilization and orientation of antibodies in serum for electrochemical biosensors. This study provides an advantageous immobilization method of serum containing antiviral antibodies to develop electrochemical biosensors for preliminary screening of viruses in clinical samples from outbreaks.

  5. Utility of HLA Antibody Testing in Kidney Transplantation

    Science.gov (United States)

    Konvalinka, Ana

    2015-01-01

    HLA antigens are polymorphic proteins expressed on donor kidney allograft endothelium and are critical targets for recipient immune recognition. HLA antibodies are risk factors for acute and chronic rejection and allograft loss. Solid-phase immunoassays for HLA antibody detection represent a major advance in sensitivity and specificity over cell-based methods and are widely used in organ allocation and pretransplant risk assessment. Post-transplant, development of de novo donor–specific HLA antibodies and/or increase in donor-specific antibodies from pretransplant levels are associated with adverse outcomes. Although single antigen bead assays have allowed sensitive detection of recipient HLA antibodies and their specificities, a number of interpretive considerations must be appreciated to understand test results in clinical and research contexts. This review, which is especially relevant for clinicians caring for transplant patients, discusses the technical aspects of single antigen bead assays, emphasizes their quantitative limitations, and explores the utility of HLA antibody testing in identifying and managing important pre- and post-transplant clinical outcomes. PMID:25804279

  6. Development and validation of an indirect Enzyme-linked Immunosorbent Assay for the detection of antibodies against Schmallenberg virus in blood samples from ruminants

    NARCIS (Netherlands)

    Heijden, van der H.M.J.F.; Bouwstra, R.J.; Mars, M.H.; Poel, van der W.H.M.; Wellenberg, G.J.; Maanen, van C.

    2013-01-01

    To detect Schmallenberg virus (SBV) infections in ruminants and to perform SBV epidemiological studies a cost-effective serological test is required. For these purposes an indirect whole virus Enzyme-linked Immunosorbent Assay (ELISA) for detection of SBV specific antibodies in ruminant blood

  7. Detection and purification of rat and goat immunoglobulin G antibodies using protein G-based solid phase radioimmunoassays

    International Nuclear Information System (INIS)

    Nilson, B.; Aakerstroem, B.; Bjoerck, L.

    1986-01-01

    Using the newly described streptococcal surface protein, protein G, which has powerful immunoglobulin G binding properties, solid-phase radioimmunoassays were developed for the quantitation of goat and rat immunoglobulin G bound to the plastic surface of microtiter plates. The binding of goat immunoglobulin G to the surface via a specific antigen (guinea pig alpha 1 -microglobulin) permitted the determination of antigen-specific antibodies with a detection limit of 50-100 ng. Optimum assay conditions were established and the whole assay procedure could be brought to completion at room temperature in less than a working day. The value of the assays was illustrated by monitoring rat and goat immunoglobulin G antibodies during their purification from whole sera by classical chromatographic procedures. (Auth.)

  8. Detection of antibodies to both M. leprae PGL-I and MMP-II to recognize leprosy patients at an early stage of disease progression.

    Science.gov (United States)

    Wang, Hongsheng; Liu, Weijing; Jin, Yali; Yu, Meiwen; Jiang, Haiqin; Tamura, Toshiki; Maeda, Yumi; Makino, Masahiko

    2015-11-01

    Antibodies to phenolic glycolipid (PGL)-I and major membrane protein (MMP)-II were evaluated for serodiagnosis of leprosy in Southwest China, and the role in predicting the occurrence of the disease in household contacts (HHCs) of leprosy was examined. Using PGL-I (natural disaccharide-octyl-bovine serum albumin) antigen-based diagnosis (IgM antibodies), we could detect 94.9% of multibacillary (MB) leprosy and 38.9% paucibacillary (PB) leprosy patients, whereas using MMP-II (IgG antibody), 88.1% of MB and 61.1% of PB patients were positive. By combining the 2 tests and considering either test positive as positive, 100% of MB patients and 72.2% of PB patients were found to test positive. Of the HHCs of leprosy, 28.3% and 30% had positive levels of PGL-I and MMP-II Abs, respectively. Seven out of 21 HHCs, who had high Ab titer to either antigen, developed leprosy during the follow-up period of 3 years. These data suggest that the measurement of both anti-PGL-I as well as anti-MMP-II antibodies could facilitate early detection of leprosy. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Towards Translational ImmunoPET/MR Imaging of Invasive Pulmonary Aspergillosis: The Humanised Monoclonal Antibody JF5 Detects Aspergillus Lung Infections In Vivo

    DEFF Research Database (Denmark)

    Davies, Genna; Rolle, Anna-Maria; Maurer, Andreas

    2017-01-01

    and magnetic resonance imaging (immunoPET/MRI) using a [64Cu] DOTA-labeled mouse monoclonal antibody (mAb), mJF5, specific to Aspergillus. To enable translation of the tracer to the clinical setting, we report here the development of a humanised version of the antibody (hJF5), and pre-clinical imaging of lung...... of the fungus from invasive lung biopsy, considered the gold standard for IPA detection, is slow and often not possible in critically ill patients. In a previous study, we reported the development of a novel non-invasive procedure for IPA diagnosis based on antibody-guided positron emission tomography...... infection using a [64Cu] NODAGA-hJF5 tracer. The humanised antibody tracer shows a significant increase in in vivo biodistribution in A. fumigatus infected lungs compared to its radiolabeled murine counterpart [64Cu] NODAGA-mJF5. Using reverse genetics of the pathogen, we show that the antibody binds...

  10. Antiphospholipid antibodies in Brazilian hepatitis C virus carriers

    Directory of Open Access Journals (Sweden)

    A.M. Atta

    2008-06-01

    Full Text Available Hepatitis C, a worldwide viral infection, is an important health problem in Brazil. The virus causes chronic infection, provoking B lymphocyte dysfunction, as represented by cryoglobulinemia, non-organ-specific autoantibody production, and non-Hodgkin's lymphoma. The aim of this research was to screen for the presence of antiphospholipid autoantibodies in 109 Brazilian hepatitis C virus carriers without clinical history of antiphospholipid syndrome. Forty healthy individuals were used as the control group. IgA, IgG, and IgM antibodies against cardiolipin and β2-glycoprotein I were measured with an enzyme-linked immunosorbent assay, using a cut-off point of either 20 UPL or 20 SBU. While 24 (22.0% hepatitis C carriers had moderate titers of IgM anticardiolipin antibodies (median, 22.5 MPL; 95%CI: 21.5-25.4 MPL, only three carriers (<3% had IgG anticardiolipin antibodies (median, 23 GPL; 95%CI: 20.5-25.5 GPL. Furthermore, IgA anticardiolipin antibodies were not detected in these individuals. Male gender and IgM anticardiolipin seropositivity were associated in the hepatitis C group (P = 0.0004. IgA anti-β2-glycoprotein-I antibodies were detected in 29 of 109 (27.0% hepatitis C carriers (median, 41 SAU; 95%CI: 52.7-103.9 SAU. Twenty patients (18.0% had IgM anti-β2-glycoprotein I antibodies (median, 27.6 SMU; 95%CI: 23.3-70.3 SMU, while two patients had IgG antibodies against this protein (titers, 33 and 78 SGU. Antiphospholipid antibodies were detected in only one healthy individual, who was seropositive for IgM anticardiolipin. We concluded that Brazilian individuals chronically infected with hepatitis C virus present a significant production of antiphospholipid antibodies, mainly IgA anti-β2-glycoprotein I antibodies, which are not associated with clinical manifestations of antiphospholipid syndrome.

  11. Imaging of primary and metastatic colorectal carcinoma with monoclonal antibody 791T/36 and the therapeutic potential of antibody-drug conjugates

    International Nuclear Information System (INIS)

    Pimm, M.V.; Armitage, N.C.; Ballantyne, K.; Baldwin, R.W.; Perkins, A.C.; Durrant, L.G.; Garnett, M.C.; Hardcastle, J.D.

    1987-01-01

    Monoclonal antibody 791T/36, prepared against a tumor-associated 72,000 dalton glycoprotein, reacted with cells from primary and metastatic colorectal carcinomas. I-131 or In-111-labelled antibody localized in xenografts of colorectal carcinomas established from in vitro clonogenic populations. Clinically, with I-131-labelled antibody, 8/11 colonic tumors imaged positively. Imaging was negative in four patients with benign colon disease. 5/11 rectal tumors were positively imaged, but excreted I-131 in the bladder obscured tumors in several studies. In-111-labelled antibody gave superior images and positively imaged primary and metastatic sites in 13/14 patients. Prospectively in the detection of recurrent disease, I-131 or In-111-antibody detected 29/33 separate sites in 24 patients. Seven negative patients remain disease free. There were 3 false positives; overall sensitivity was 88%, with 70% specificity. Specific localization of radiolabel was confirmed immunochemically and by counting radioactivity in resected specimens. Antibody conjugates with methotrexate, vindesine and daunomycin retained drug activity and antibody function, including xenograft localization and conjugates were therapeutically effective against xenografts. 791T/36 antibody has potential for immunodetection of primary and recurrent colorectal carcinoma and for targeting of therapeutic agents

  12. Microspot-based ELISA in microfluidics: chemiluminescence and colorimetry detection using integrated thin-film hydrogenated amorphous silicon photodiodes.

    Science.gov (United States)

    Novo, Pedro; Prazeres, Duarte Miguel França; Chu, Virginia; Conde, João Pedro

    2011-12-07

    Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.

  13. Sensitive detection of capsaicinoids using a surface plasmon resonance sensor with anti-homovanillic Acid polyclonal antibodies.

    Science.gov (United States)

    Nakamura, Shingo; Yatabe, Rui; Onodera, Takeshi; Toko, Kiyoshi

    2013-11-13

    Recently, highly functional biosensors have been developed in preparation for possible large-scale terrorist attacks using chemical warfare agents. Practically applicable sensors are required to have various abilities, such as high portability and operability, the capability of performing rapid and continuous measurement, as well as high sensitivity and selectivity. We developed the detection method of capsaicinoids, the main component of some lachrymators, using a surface plasmon resonance (SPR) immunosensor as an on-site detection sensor. Homovanillic acid, which has a vanillyl group similar to capsaicinoids such as capsaicin and dihydrocapsaicin, was bound to Concholepas concholepas hemocyanin (CCH) for use as an immunogen to generate polyclonal antibodies. An indirect competitive assay was carried out to detect capsaicinoids using SPR sensor chips on which different capsaicin analogues were immobilized. For the sensor chip on which 4-hydroxy-3-methoxybenzylamine hydrochloride was immobilized, a detection limit of 150 ppb was achieved. We found that the incubation time was not required and the detection can be completed in five minutes.

  14. Solid-phase radioimmunoassay for the detection fo IgG antibodies to gramineae pollen (Dactylis glomerata) and to acarida (dermatophagoides Pteronyssinus)

    International Nuclear Information System (INIS)

    Guilloux, L.; Ville, G.

    1985-01-01

    A solid-phase radioimmunoassay using 125 I-protein A onto polystyrene microplates, was applied successfully for the detection of IgG antibodies to acarida and to grass pollen in allergic patients and in patients undergoing desensitization therapy [fr

  15. Anti-Podocalyxin Monoclonal Antibody 47-mG2a Detects Lung Cancers by Immunohistochemistry.

    Science.gov (United States)

    Yamada, Shinji; Itai, Shunsuke; Kaneko, Mika K; Kato, Yukinari

    2018-04-01

    Lung cancer is one of the leading causes of cancer-related deaths in the world. Regardless of the advances in lung cancer treatments, the prognosis is still poor. Podocalyxin (PODXL) is a highly glycosylated type I transmembrane protein that is expressed in normal tissues, including the heart, pancreas, and breast. It is also found and used as a diagnostic marker in many cancers, such as renal, brain, breast, oral, and lung cancers. We previously developed specific and sensitive anti-PODXL monoclonal antibodies, PcMab-47 (mouse IgG 1 , kappa) and its mouse IgG 2a -type (47-mG 2a ), both of which were suitable for immunohistochemical analyses of oral cancers. In this study, we investigated the utility of PcMab-47 and 47-mG 2a for the immunohistochemical analyses of lung cancers. PcMab-47 stained 51/70 (72.9%) cases of lung cancer, whereas 47-mG 2a stained 59/70 (84.3%) cases, indicating that the latter antibody is more sensitive and is useful for detecting PODXL in lung cancers.

  16. Novel enzyme immunoassay system for simultaneous detection of six subclasses of antiphospholipid antibodies for differential diagnosis of antiphospholipid syndrome.

    Science.gov (United States)

    Nojima, Junzo; Motoki, Yukari; Hara, Kazusa; Sakata, Toshiyuki; Ichihara, Kiyoshi

    2017-06-01

    : Antiphospholipid syndrome, which often complicates systemic lupus erythematosus (SLE), features high occurrence of arterial and/or venous thrombosis and recurrent fetal loss. However, which antibody subclass contributes to which clinical event remains uncertain. We newly developed an up-to-date enzyme immunoassay system using the AcuStar automated analyzer (Instrumentation Laboratory, Bedford, Massachusetts, USA) for parallel detection of six subclasses of antiphospholipid antibodies (aPLs): anticardiolipin antibodies (aCL) of IgG, IgM, and IgA and anti-β2-glycoprotein I antibodies (aβ2GPI) of IgG, IgM, and IgA. They were measured in 276 healthy volunteers and 138 patients with SLE: 45 with thromboembolic complications (29 arterial; 16 venous) and 93 without. Lupus anticoagulant activity in their plasma was measured according to the guidelines recommended by the Subcommittee on Lupus Anticoagulant/Phospholipid-Dependent Antibodies. aCL/β2GPI was measured with a standard ELISA kit commonly used in Japan. The positive results of IgG aCL, IgA aCL, and IgG aβ2GPI were closely associated with thromboembolic complications, whereas IgM aCL and IgM aβ2GPI were not. receiver operating characteristic analysis revealed that the accuracy of predicting thromboembolic complications based on the composite test results of the former three antibodies were obviously higher than by each alone. Regarding agreement with the test results of lupus anticoagulant activity, IgG aβ2GPI showed the closest match. Patients with SLE frequently possess various combinations of the six aPL subclasses, and this antibody spectrum is closely associated with thromboembolic events in these patients. This new automated enzyme immunoassay system allows simultaneous analysis of the profile of aPL subclasses for the differential diagnosis of antiphospholipid antibody syndrome in its early stage.

  17. Enhanced sensitivity in detection of antiviral antibody responses using biotinylation of foot-and-mouth disease virus (FMDV) capsids.

    Science.gov (United States)

    Kenney, Mary; Waters, Ryan A; Rieder, Elizabeth; Pega, Juan; Perez-Filguera, Mariano; Golde, William T

    2017-11-01

    Analysis of the immune response to infection of livestock by foot-and-mouth disease virus (FMDV) is most often reported as the serum antibody response to the virus. While measurement of neutralizing antibody has been sensitive and specific, measurements of the quality of the antibody response are less robust. Determining the immunoglobulin (Ig) isotype of the serum antibody response provides a deeper understanding of the biology of the response and more sensitive methods for these assays will facilitate analyses of B cell mediated immunity. We tested the hypothesis that using the virus as the molecular probe could be achieved by adding tags to the surface of the FMDV capsid, and that would enhance sensitivity in assays for anti-FMDV antibody responses. The use of a FLAG-tagged virus in these assays failed to yield improvement whereas chemically biotinylating the virus capsid resulted in significant enhancement of the signal. Here we describe methods using biotinylated virus for measuring anti-viral antibody in serum and antibody secreting cells (ASCs) in blood that are sensitive and specific. Finally, we describe using the biotinylated virus in flow cytometry where such assays should greatly enhance the analysis of anti-virus antibody producing B cells, allowing the investigator to focus on only the FMDV specific B cells when analyzing the development of the B cell response to either infection or vaccination. Published by Elsevier B.V.

  18. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  19. Antibodies to Pseudogymnoascus destructans are not sufficient for protection against white-nose syndrome.

    Science.gov (United States)

    Johnson, Joseph S; Reeder, DeeAnn M; Lilley, Thomas M; Czirják, Gábor Á; Voigt, Christian C; McMichael, James W; Meierhofer, Melissa B; Seery, Christopher W; Lumadue, Shayne S; Altmann, Alexander J; Toro, Michael O; Field, Kenneth A

    2015-06-01

    White-nose syndrome (WNS) is a fungal disease caused by Pseudogymnoascus destructans (Pd) that affects bats during hibernation. Although millions of bats have died from WNS in North America, mass mortality has not been observed among European bats infected by the fungus, leading to the suggestion that bats in Europe are immune. We tested the hypothesis that an antibody-mediated immune response can provide protection against WNS by quantifying antibodies reactive to Pd in blood samples from seven species of free-ranging bats in North America and two free-ranging species in Europe. We also quantified antibodies in blood samples from little brown myotis (Myotis lucifugus) that were part of a captive colony that we injected with live Pd spores mixed with adjuvant, as well as individuals surviving a captive Pd infection trial. Seroprevalence of antibodies against Pd, as well as antibody titers, was greater among little brown myotis than among four other species of cave-hibernating bats in North America, including species with markedly lower WNS mortality rates. Among little brown myotis, the greatest titers occurred in populations occupying regions with longer histories of WNS, where bats lacked secondary symptoms of WNS. We detected antibodies cross-reactive with Pd among little brown myotis naïve to the fungus. We observed high titers among captive little brown myotis injected with Pd. We did not detect antibodies against Pd in Pd-infected European bats during winter, and titers during the active season were lower than among little brown myotis. These results show that antibody-mediated immunity cannot explain survival of European bats infected with Pd and that little brown myotis respond differently to Pd than species with higher WNS survival rates. Although it appears that some species of bats in North America may be developing resistance to WNS, an antibody-mediated immune response does not provide an explanation for these remnant populations.

  20. [Neuroimmunological diseases associated with VGKC complex antibodies].

    Science.gov (United States)

    Watanabe, Osamu

    2013-05-01

    Antibodies to voltage-gated potassium channels(VGKC) were first identified by radioimmunoassay of radioisotope labeled alpha-dendrotoxin-VGKCs solubilized from rabbit brain. These antibodies were found only in a proportion of patients with acquired neuromyotonia (Isaacs' syndrome). VGKC antibodies were also detected in Morvan's syndrome and in a form of autoimmune limbic encephalitis. Recent studies indicated that the "VGKC" antibodies are mainly directed toward associated proteins(for example LGI-1, Caspr-2) that complex with the VGKCs themselves. The "VGKC" antibodies are now usually known as VGKC-complex antibodies. In general, LGI-1 antibodies are most common in limbic encephalitis with SIADH. Caspr-2 antibodies are present in the majority of patients with Morvan's syndrome. These patients develop combinations of CNS symptoms, autonomic dysfunction, and peripheral nerve hyperexcitability.

  1. Dengue virus specific IgY provides protection following lethal dengue virus challenge and is neutralizing in the absence of inducing antibody dependent enhancement.

    Science.gov (United States)

    Fink, Ashley L; Williams, Katherine L; Harris, Eva; Alvine, Travis D; Henderson, Thomas; Schiltz, James; Nilles, Matthew L; Bradley, David S

    2017-07-01

    Dengue hemorrhagic fever (DHF) and dengue shock syndrome (DSS) are severe disease manifestations that can occur following sequential infection with different dengue virus serotypes (DENV1-4). At present, there are no licensed therapies to treat DENV-induced disease. DHF and DSS are thought to be mediated by serotype cross-reactive antibodies that facilitate antibody-dependent enhancement (ADE) by binding to viral antigens and then Fcγ receptors (FcγR) on target myeloid cells. Using genetically engineered DENV-specific antibodies, it has been shown that the interaction between the Fc portion of serotype cross-reactive antibodies and FcγR is required to induce ADE. Additionally, it was demonstrated that these antibodies were as neutralizing as their non-modified variants, were incapable of inducing ADE, and were therapeutic following a lethal, antibody-enhanced infection. Therefore, we hypothesized that avian IgY, which do not interact with mammalian FcγR, would provide a novel therapy for DENV-induced disease. We demonstrate here that goose-derived anti-DENV2 IgY neutralized DENV2 and did not induce ADE in vitro. Anti-DENV2 IgY was also protective in vivo when administered 24 hours following a lethal DENV2 infection. We were also able to demonstrate via epitope mapping that both full-length and alternatively spliced anti-DENV2 IgY recognized different epitopes, including epitopes that have not been previously identified. These observations provide evidence for the potential therapeutic applications of goose-derived anti-DENV2 IgY.

  2. Dengue virus specific IgY provides protection following lethal dengue virus challenge and is neutralizing in the absence of inducing antibody dependent enhancement.

    Directory of Open Access Journals (Sweden)

    Ashley L Fink

    2017-07-01

    Full Text Available Dengue hemorrhagic fever (DHF and dengue shock syndrome (DSS are severe disease manifestations that can occur following sequential infection with different dengue virus serotypes (DENV1-4. At present, there are no licensed therapies to treat DENV-induced disease. DHF and DSS are thought to be mediated by serotype cross-reactive antibodies that facilitate antibody-dependent enhancement (ADE by binding to viral antigens and then Fcγ receptors (FcγR on target myeloid cells. Using genetically engineered DENV-specific antibodies, it has been shown that the interaction between the Fc portion of serotype cross-reactive antibodies and FcγR is required to induce ADE. Additionally, it was demonstrated that these antibodies were as neutralizing as their non-modified variants, were incapable of inducing ADE, and were therapeutic following a lethal, antibody-enhanced infection. Therefore, we hypothesized that avian IgY, which do not interact with mammalian FcγR, would provide a novel therapy for DENV-induced disease. We demonstrate here that goose-derived anti-DENV2 IgY neutralized DENV2 and did not induce ADE in vitro. Anti-DENV2 IgY was also protective in vivo when administered 24 hours following a lethal DENV2 infection. We were also able to demonstrate via epitope mapping that both full-length and alternatively spliced anti-DENV2 IgY recognized different epitopes, including epitopes that have not been previously identified. These observations provide evidence for the potential therapeutic applications of goose-derived anti-DENV2 IgY.

  3. Detection of Antibodies against Paracoccidioides brasiliensis Melanin in In Vitro and In Vivo Studies during Infection ▿

    Science.gov (United States)

    Urán, Martha E.; Nosanchuk, Joshua D.; Restrepo, Angela; Hamilton, Andrew J.; Gómez, Beatriz L.; Cano, Luz E.

    2011-01-01

    Several cell wall constituents, including melanins or melanin-like compounds, have been implicated in the pathogenesis of a wide variety of microbial diseases caused by diverse species of pathogenic bacteria, fungi, and helminthes. Among these microorganisms, the dimorphic fungal pathogen Paracoccidioides brasiliensis produces melanin in its conidial and yeast forms. In the present study, melanin particles from P. brasiliensis were injected into BALB/c mice in order to produce monoclonal antibodies (MAbs). We identified five immunoglobulin G1 (IgG1) κ-chain and four IgM melanin-binding MAbs. The five IgG1 κ-chain isotypes are the first melanin-binding IgG MAbs ever reported. The nine MAbs labeled P. brasiliensis conidia and yeast cells both in vitro and in pulmonary tissues. The MAbs cross-reacted with melanin-like purified particles from other fungi and also with commercial melanins, such as synthetic and Sepia officinalis melanin. Melanization during paracoccidioidomycosis (PCM) was also further supported by the detection of IgG antibodies reactive to melanin from P. brasiliensis conidia and yeast in sera and bronchoalveolar lavage fluids from P. brasiliensis-infected mice, as well as in sera from human patients with PCM. Serum specimens from patients with other mycoses were also tested for melanin-binding antibodies by enzyme-linked immunosorbent assay, and cross-reactivities were detected for melanin particles from different fungal sources. These results suggest that melanin from P. brasiliensis is an immunologically active fungal structure that activates a strong IgG humoral response in humans and mice. PMID:21813659

  4. Imaging of colorectal carcinoma with radiolabeled antibodies.

    Science.gov (United States)

    Goldenberg, D M; Goldenberg, H; Sharkey, R M; Lee, R E; Higgenbotham-Ford, E; Horowitz, J A; Hall, T C; Pinsky, C M; Hansen, H J

    1989-10-01

    Colorectal cancer has been the tumor type most frequently studied with radiolabeled antibodies. Among the various antibodies, a majority of patients with colorectal cancer have received xenogeneic polyclonal or monoclonal antibodies against carcino-embryonic antigen. This review summarizes the current status of colorectal cancer imaging with radiolabeled antibodies, ie, radioimmunodetection (RAID), and examines the published studies involving carcinoembryonic antigen (CEA) antibodies and 17-1A, 19-9, and B72.3, and other monoclonal antibodies. In order to better address the issue of the current and future clinical usefulness of this emerging technology, particular attention is given to the protocols, methods, and results of the published studies. Despite differences in study parameters, antibodies and forms, labels, administration routes and doses, and scanning instruments and methods, it has been found that (1) almost no adverse reactions have been evident; (2) antibody fragments are preferred over whole immunoglobulin G reagents because they achieve higher tumor-to-background ratios earlier, thus reducing or precluding the need for dual-isotope subtraction methods or long delays before imaging; (3) use of antibody fragments, including the monovalent Fab' form, permits imaging with short-lived radionuclides of excellent photon properties, such as 123I and 99mTc; (4) circulating antigens against which the imaging antibody is directed can complex with the injected antibody, but such complexes have not prevented successful RAID; (5) patients with high serum titers of the appropriate antigen target usually have higher rates of positive RAID; (6) patients who are seronegative for the tumor antigen being studied can have positive RAID findings, which can represent the detection of occult lesions; (7) single photon emission computed tomography appears to provide better image resolution than planar scanning; (8) regardless of the sensitivity reported in any particular

  5. Simple dipstick assay for the detection of Salmonella typhi-specific IgM antibodies and the evolution of the immune response in patients with typhoid fever

    NARCIS (Netherlands)

    Hatta, Mochammad; Goris, Marga G. A.; Heerkens, Evy; Gooskens, Jairo; Smits, Henk L.

    2002-01-01

    Application of a dipstick assay for the detection of Salmonella typhi-specific IgM antibodies on samples collected from S. typhi or S. paratyphi culture-positive patients at the day of admission to the hospital revealed the presence of specific IgM antibodies in 43.5%, 92.9%, and 100% for samples

  6. Stratification of antibody-positive subjects by antibody level reveals an impact of immunogenicity on pharmacokinetics.

    Science.gov (United States)

    Zhou, Lei; Hoofring, Sarah A; Wu, Yu; Vu, Thuy; Ma, Peiming; Swanson, Steven J; Chirmule, Narendra; Starcevic, Marta

    2013-01-01

    The availability of highly sensitive immunoassays enables the detection of antidrug antibody (ADA) responses of various concentrations and affinities. The analysis of the impact of antibody status on drug pharmacokinetics (PK) is confounded by the presence of low-affinity or low-concentration antibody responses within the dataset. In a phase 2 clinical trial, a large proportion of subjects (45%) developed ADA following weekly dosing with AMG 317, a fully human monoclonal antibody therapeutic. The antibody responses displayed a wide range of relative concentrations (30 ng/mL to >13 μg/mL) and peaked at various times during the study. To evaluate the impact of immunogenicity on PK, AMG 317 concentration data were analyzed following stratification by dose group, time point, antibody status (positive or negative), and antibody level (relative concentration). With dose group as a stratifying variable, a moderate reduction in AMG 317 levels (AMG 317 levels was revealed when antibody data was stratified by both time point and antibody level. In general, high ADA concentrations (>500 ng/mL) and later time points (week 12) were associated with significantly (up to 97%) lower trough AMG 317 concentrations. The use of quasi-quantitative antibody data and appropriate statistical methods was critical for the most comprehensive evaluation of the impact of immunogenicity on PK.

  7. Exceptional Antibodies Produced by Successive Immunizations.

    Directory of Open Access Journals (Sweden)

    Patricia J Gearhart

    2015-12-01

    Full Text Available Antibodies stand between us and pathogens. Viruses mutate quickly to avoid detection, and antibodies mutate at similar rates to hunt them down. This death spiral is fueled by specialized proteins and error-prone polymerases that change DNA sequences. Here, we explore how B lymphocytes stay in the race by expressing activation-induced deaminase, which unleashes a tsunami of mutations in the immunoglobulin loci. This produces random DNA substitutions, followed by selection for the highest affinity antibodies. We may be able to manipulate the process to produce better antibodies by expanding the repertoire of specific B cells through successive vaccinations.

  8. Effect of screening for red cell antibodies, other than anti-D, to detect hemolytic disease of the fetus and newborn: a population study in the Netherlands

    NARCIS (Netherlands)

    Koelewijn, J. M.; Vrijkotte, T. G. M.; van der Schoot, C. E.; Bonsel, G. J.; de Haas, M.

    2008-01-01

    BACKGROUND: Hemolytic disease of the fetus and newborn (HDFN) is a severe disease, resulting from maternal red cell (RBC) alloantibodies directed against fetal RBCs. The effect of a first-trimester antibody screening program on the timely detection of HDFN caused by antibodies other than anti-D was

  9. Antibody Prevalence to Influenza Type A in Wild Boar of Northern Ukraine.

    Science.gov (United States)

    Kovalenko, Ganna; Molozhanova, Alona; Halka, Ihor; Nychyk, Serhiy

    2017-12-01

    A preliminary serological survey was carried out to assess the likelihood of influenza A (IA) infection in wild boar and begin to characterize the role of wild boar in the epidemiology of the IA virus (IAV). Sera collected from 120 wild boar that were hunted in 2014 were tested. To detect antibodies to IA, a blocking the enzyme-linked immunosorbent assay (ELISA) was used. Thirty boar were collected from each of four oblasts in the north central and northwestern regions of Ukraine. Antibodies against IAV were detected in 27 samples (22.5%; 95% confidence interval 16.0-30.8) and in at least some of the wild boar from all of the four oblasts. This preliminary survey of IA antibodies in wild boar populations of northern Ukraine indicates a substantial frequency of exposure to IAV throughout the region. Infection of wild boar populations could provide an alternative or additional route for spillover from wild populations to domestic animals and humans.

  10. Antibody Desensitization Therapy in Highly Sensitized Lung Transplant Candidates

    Science.gov (United States)

    Snyder, L. D.; Gray, A. L.; Reynolds, J. M.; Arepally, G. M.; Bedoya, A.; Hartwig, M. G.; Davis, R. D.; Lopes, K. E.; Wegner, W. E.; Chen, D. F.; Palmer, S. M.

    2015-01-01

    As HLAs antibody detection technology has evolved, there is now detailed HLA antibody information available on prospective transplant recipients. Determining single antigen antibody specificity allows for a calculated panel reactive antibodies (cPRA) value, providing an estimate of the effective donor pool. For broadly sensitized lung transplant candidates (cPRA ≥ 80%), our center adopted a pretransplant multimodal desensitization protocol in an effort to decrease the cPRA and expand the donor pool. This desensitization protocol included plasmapheresis, solumedrol, bortezomib and rituximab given in combination over 19 days followed by intravenous immunoglobulin. Eight of 18 candidates completed therapy with the primary reasons for early discontinuation being transplant (by avoiding unacceptable antigens) or thrombocytopenia. In a mixed-model analysis, there were no significant changes in PRA or cPRA changes over time with the protocol. A sub-analysis of the median fluorescence intensity (MFI) change indicated a small decline that was significant in antibodies with MFI 5000–10 000. Nine of 18 candidates subsequently had a transplant. Posttransplant survival in these nine recipients was comparable to other pretransplant-sensitized recipients who did not receive therapy. In summary, an aggressive multi-modal desensitization protocol does not significantly reduce pretransplant HLA antibodies in a broadly sensitized lung transplant candidate cohort. PMID:24666831

  11. Progranulin antibodies in autoimmune diseases.

    Science.gov (United States)

    Thurner, Lorenz; Preuss, Klaus-Dieter; Fadle, Natalie; Regitz, Evi; Klemm, Philipp; Zaks, Marina; Kemele, Maria; Hasenfus, Andrea; Csernok, Elena; Gross, Wolfgang L; Pasquali, Jean-Louis; Martin, Thierry; Bohle, Rainer Maria; Pfreundschuh, Michael

    2013-05-01

    Systemic vasculitides constitute a heterogeneous group of diseases. Autoimmunity mediated by B lymphocytes and their humoral effector mechanisms play a major role in ANCA-associated vasculitis (AAV) as well as in non-ANCA associated primary systemic vasculitides and in the different types of autoimmune connective tissue disorders and rheumatoid arthritis. In order to detect autoantibodies in systemic vasculitides, we screened protein macroarrays of human cDNA expression libraries with sera from patients with ANCA-associated and ANCA-negative primary systemic vasculitides. This approach led to the identification of antibodies against progranulin, a 88 kDA secreted glycoprotein with strong anti-inflammatory activity in the course of disease of giant-cell arteritis/polymyalgia rheumatica (14/65), Takayasu's arteritis (4/13), classical panarteritis nodosa (4/10), Behcet's disease (2/6) and in the course of disease in granulomatosis with polyangiitis (31/75), Churg-Strauss syndrome (7/23) and in microscopic polyangiitis (7/19). In extended screenings the progranulin antibodies were also detected in other autoimmune diseases such as systemic lupus erythematosus (39/91) and rheumatoid arthritis (16/44). Progranulin antibodies were detected only in 1 of 97 healthy controls. Anti-progranulin positive patients with systemic vasculitides, systemic lupus erythematosus or rheumatoid arthritis had significant lower progranulin plasma levels, indicating a neutralizing effect. In light of the anti-inflammatory effects of progranulin, progranulin antibodies might exert pro-inflammatory effects thus contributing to the pathogenesis of the respective autoimmune diseases and might serve as a marker for disease activity. This hypothesis is supported by the fact that a positive progranulin antibody status was associated with active disease in granulomatosis with polyangiitis. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Avian influenza virus antibodies in Pacific Coast Red Knots (Calidris canutus rufa)

    Science.gov (United States)

    Johnson, James A.; DeCicco, Lucas H.; Ruthrauff, Daniel R.; Krauss, Scott; Hall, Jeffrey S.

    2014-01-01

    Prevalence of avian influenza virus (AIV) antibodies in the western Atlantic subspecies of Red Knot (Calidris canutus rufa) is among the highest for any shorebird. To assess whether the frequency of detection of AIV antibodies is high for the species in general or restricted only to C. c. rufa, we sampled the northeastern Pacific Coast subspecies of Red Knot (Calidris canutus roselaari) breeding in northwestern Alaska. Antibodies were detected in 90% of adults and none of the chicks sampled. Viral shedding was not detected in adults or chicks. These results suggest a predisposition of Red Knots to AIV infection. High antibody titers to subtypes H3 and H4 were detected, whereas low to intermediate antibody levels were found for subtypes H10 and H11. These four subtypes have previously been detected in shorebirds at Delaware Bay (at the border of New Jersey and Delaware) and in waterfowl along the Pacific Coast of North America.

  13. Detection of anti-neutrophil antibodies in autoimmune neutropenia of infancy: a multicenter study.

    Science.gov (United States)

    Sella, Ruti; Flomenblit, Lena; Goldstein, Itamar; Kaplinsky, Chaim

    2010-02-01

    Autoimmune neutropenia of infancy is caused by neutrophil-specific autoantibodies. Primary AIN is characterized by neutrophil count familial or congenital neutropenias. To further assure the quality of the new test, we retested six samples previously tested by the gold standard method. All medical files were screened and clinical outcomes were recorded. Our method showed specificity of 85%, sensitivity of 62.5%, and a positive predictive value of 91.8%, values quite similar to those obtained by more traditional methods. The new method showed high specificity for detection of anti-neutrophil antibodies in the appropriate clinical setting and could be an effective tool for clinical decision making.

  14. DETECTION AND PURIFICATION OF TYROSINE-SULFATED PROTEINS USING A NOVEL ANTI-SULFOTYROSINE MONOCLONAL ANTIBODY*

    Science.gov (United States)

    Hoffhines, Adam J.; Damoc, Eugen; Bridges, Kristie G.; Leary, Julie A.; Moore, Kevin L.

    2006-01-01

    Protein-tyrosine O-sulfation is a post-translational modification mediated by one of two Golgi tyrosylprotein sulfotransferases (TPST-1 & TPST-2) that catalyze the transfer of sulfate to tyrosine residues in secreted and transmembrane proteins. Tyrosine sulfation plays a role in protein-protein interactions in several well-defined systems. Although dozens of tyrosine-sulfated proteins are known, many more are likely to exist and await description. Advancing our understanding of the importance of tyrosine sulfation in biological systems requires the development of new tools for the detection and study of tyrosine-sulfated proteins. We have developed a novel anti-sulfotyrosine monoclonal antibody, called PSG2, that binds with high affinity and exquisite specificity to sulfotyrosine residues in peptides and proteins independent of sequence context. We show that it can detect tyrosinesulfated proteins in complex biological samples and can be used as a probe to assess the role of tyrosine sulfation in protein function. We also demonstrate the utility of PSG2 in the purification of tyrosine-sulfated proteins from crude tissue samples. Finally, Western blot analysis using PSG2 indicates that certain sperm/epididymal proteins are undersulfated in Tpst2−/− mice. This indicates that TPST-1 and TPST-2 have distinct macromolecular substrate specificities and provides clues as to the molecular mechanism of the infertility of Tpst2−/− males. PSG2 should be widely applicable for identification of tyrosine-sulfated proteins in other systems and organisms. PMID:17046811

  15. Performance evaluation of a novel chemiluminescence assay for detection of anti-GBM antibodies: an international multicenter study.

    Science.gov (United States)

    Mahler, Michael; Radice, Antonella; Sinico, Renato A; Damoiseaux, Jan; Seaman, Andrea; Buckmelter, Kristen; Vizjak, Alenka; Buchner, Carol; Binder, Walter L; Fritzler, Marvin J; Cui, Zhao

    2012-01-01

    Autoantibodies to the non-collagen region (NC1) of the alpha-3 subunit of collagen IV represent a serological hallmark in the diagnosis of Goodpasture's syndrome (GPS). The objective of our study was to carefully analyze the performance characteristics of a novel anti-glomerular basement membrane (GBM) chemiluminescence immunoassay (CIA). Sera from patients with GPS (n = 90) were collected from four clinical centers. Samples from different disease groups (n = 397) and healthy individuals (n = 400) were used as controls. All samples were tested for anti-GBM antibodies by a rapid, random access CIA (QUANTA Flash™ GBM). Most of the samples were also tested using other methods including different commercial anti-GBM IgG assays and research assays for anti-GBM IgA and IgM. The sensitivity and specificity of the novel CIA was 95.6% [95% confidence interval (CI) 89.0-98.8%] and 99.6% (95% CI 98.9-99.9%), respectively. Receiver operating characteristic analysis showed good discrimination between GPS patients and controls. The area under the curve was 0.98 (CI 0.96-1.0). The three anti-GBM antibody-positive samples from the control group were from two healthy individuals and one human immunodeficiency virus (HIV)-infected patient. All three individuals had low levels of anti-GBM antibodies [20, 24 and 25 chemiluminescent unit (CU), cutoff 20 CU]. When the results of the new CIA were compared to other methods, good agreement was observed: 95.8% (kappa = 0.92) versus EliA™ GBM, 97.4% (kappa = 0.95) versus both BINDAZYME™ Anti-GBM and QUANTA Lite® GBM. Anti-GBM IgA was detectable in low concentrations in patients with GPS and was associated with anti-GBM IgG but was less useful in discriminating GPS patients and controls. No discrimination was found for anti-GBM IgM. The novel QUANTA Flash™ GBM CIA demonstrated good sensitivity and specificity and had good agreement with other methods. Our data confirm that ∼5% of patients with GPS do not have detectable levels of

  16. Validation of a commercially available indirect ELISA using a nucleocapside recombinant protein for detection of Schmallenberg virus antibodies.

    Directory of Open Access Journals (Sweden)

    Emmanuel Bréard

    Full Text Available A newly developed Enzym Like Immuno Sorbant Assay (ELISA based on the recombinant nucleocapsid protein (N of Schmallenberg virus (SBV was evaluated and validated for the detection of SBV-specific IgG antibodies in ruminant sera by three European Reference Laboratories. Validation data sets derived from sheep, goat and bovine sera collected in France and Germany (n = 1515 in 2011 and 2012 were categorized according to the results of a virus neutralization test (VNT or an indirect immuno-fluorescence assay (IFA. The specificity was evaluated with 1364 sera from sheep, goat and bovine collected in France and Belgium before 2009. Overall agreement between VNT and ELISA was 98.9% and 98.3% between VNT and IFA, indicating a very good concordance between the different techniques. Although cross-reactions with other Orthobunyavirus from the Simbu serogroup viruses might occur, it is a highly sensitive, specific and robust ELISA-test validated to detect anti-SBV antibodies. This test can be applied for SBV sero-diagnostics and disease-surveillance studies in ruminant species in Europe.

  17. Long-Term Effects of Antibodies Against Human Leukocyte Antigens Detected by Flow Cytometry in the First Year After Renal Transplantation

    Directory of Open Access Journals (Sweden)

    Tülay Kılıçaslan Ayna

    2013-03-01

    Full Text Available Objective: In this study, we aimed to investigate the incidence, dynamics and profiles of human leukocyte antigen (HLA-directed antibodies developed after transplantation and their impact on graft rejection and outcome in kidney recipients. Study Design: Prospective follow-up study. Material and Methods: A total of 56 kidney recipients were monitored at 1st, 6th and 12th months for the development of anti-HLA antibodies using bead based flow-cytometry assays (Flow PRA tests. Results: In 21 (37.5% patients, panel reactive antibodies (PRA was positive after transplantation, however, in 35 (62.5% patients PRA was found negative. Twelve (57.1% patients with post-transplantation HLA-reactive antibodies [PRA (+] and 8 (22.9% patients with no detectable alloantibodies [PRA (-] were developed allograft rejection (p=0.010. In the PRA positive patient group the rates of early period infection and delayed graft function (DGF were higher than the PRA negative patient group. Serum creatinine levels of PRA positive group at 6. and 12. months after transplantation were significantly higher than the PRA negative group (p=0.015 and p=0.048, respectively. The rejection rates of patients who had class I and II HLA antibodies were significantly higher than the patients who had either class I or II HLA antibodies (p=0.011. Acute rejection rates were significantly higher in patients who had class I and II HLA antibodies at the first month (p=0.007. Conclusion: Higher occurrence of rejection episodes in PRA positive group may show the importance of anti-HLA antibody monitoring using Flow-PRA after renal transplantation as a prognostic marker in terms of graft survival.

  18. Comparison of enzyme-linked immunosorbent assay, radioimmunoassay, complement fixation, anticomplement immunofluorescence and passive haemaglutination techniques for detecting cytomegalovirus IgG antibody

    Energy Technology Data Exchange (ETDEWEB)

    Booth, J C; Hannington, G; Bakir, T M.F.; Stern, H; Kangro, H; Griffiths, P D; Heath, R B [Saint George' s Hospital Medical School, London (UK); Saint Bartholomew' s Hospital, London (UK))

    1982-12-01

    The radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) techniques were found to be comparable in sensitivity and specificity for detecting cytomegalovirus IgG antibody, and 10 to 100 times more sensitive than complement-fixation (CF), anticomplement immunofluorescence (ACIF) and passive haemagglutination (PHA). In screening tests for antibody, the frequency of false-positive and -negative results was 0.6% for RIA and ELISA, 1.5% for CF, 1.6% for ACIF and 3.6% for PHA. PHA was the least satisfactory test, largely because of technical problems.

  19. Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

    Science.gov (United States)

    Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin

    2017-06-01

    Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.

  20. Gold Nanoparticles-Based Barcode Analysis for Detection of Norepinephrine.

    Science.gov (United States)

    An, Jeung Hee; Lee, Kwon-Jai; Choi, Jeong-Woo

    2016-02-01

    Nanotechnology-based bio-barcode amplification analysis offers an innovative approach for detecting neurotransmitters. We evaluated the efficacy of this method for detecting norepinephrine in normal and oxidative-stress damaged dopaminergic cells. Our approach use a combination of DNA barcodes and bead-based immunoassays for detecting neurotransmitters with surface-enhanced Raman spectroscopy (SERS), and provides polymerase chain reaction (PCR)-like sensitivity. This method relies on magnetic Dynabeads containing antibodies and nanoparticles that are loaded both with DNA barcords and with antibodies that can sandwich the target protein captured by the Dynabead-bound antibodies. The aggregate sandwich structures are magnetically separated from the solution and treated to remove the conjugated barcode DNA. The DNA barcodes are then identified by SERS and PCR analysis. The concentration of norepinephrine in dopaminergic cells can be readily detected using the bio-barcode assay, which is a rapid, high-throughput screening tool for detecting neurotransmitters.

  1. The use of whole blood in a dipstick assay for detection of antibodies to Mycobacterium leprae: a field evaluation

    NARCIS (Netherlands)

    Bührer-Sekula, S.; Cunha, M. G.; Ferreira, W. A.; Klatser, P. R.

    1998-01-01

    We describe a further simplification of a dipstick assay for the detection of antibodies to phenolic glycolipid I of Mycobacterium leprae by using whole blood and evaluated the assay performance in the leprosy endemic area of Amazonas in Brazil. The agreement with the 'gold' standard ELISA was 94.9%

  2. Generation of HER2 monoclonal antibodies using epitopes of a rabbit polyclonal antibody.

    Science.gov (United States)

    Hu, Francis Jingxin; Uhlen, Mathias; Rockberg, Johan

    2014-01-25

    One of the issues in using polyclonal antibodies is the limited amount of reagent available from an immunisation, leading to batch-to-batch variation and difficulties in obtaining the same antibody performance when the same antigen is re-immunised into several separate animals. This led to the development of hybridoma technology allowing, at least theoretically, for an unlimited production of a specific binder. Nevertheless, polyclonal antibodies are widely used in research and diagnostics and there exists a need for robust methods to convert a polyclonal antibody with good binding performance into a renewable monoclonal with identical or similar binding specificity. Here we have used precise information regarding the functional recognition sequence (epitope) of a rabbit polyclonal antibody with attractive binding characteristics as the basis for generation of a renewable mouse monoclonal antibody. First, the original protein fragment antigen was used for immunisation and generation of mouse hybridoma, without obtaining binders to the same epitope region. Instead a peptide designed using the functional epitope and structural information was synthesised and used for hybridoma production. Several of the monoclonal antibodies generated were found to have similar binding characteristics to those of the original polyclonal antibody. These monoclonal antibodies detected native HER2 on cell lines and were also able to stain HER2 in immunohistochemistry using xenografted mice, as well as human normal and cancer tissues. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Detection and characterization of Leishmania in tissues of patients with post kala-azar dermal leishmaniasis using a specific monoclonal antibody

    DEFF Research Database (Denmark)

    Ismail, A; Kharazmi, A; Permin, H

    1997-01-01

    Sections from skin lesions and draining lymph nodes of patients with post kala-azar dermal leishmaniasis were examined using an immunoperoxidase method and a monoclonal antibody directed against Leishmania donovani. Parasites were detected in 22 of 25 biopsies (88%). In parallel sections stained...

  4. A High-Throughput Antibody-Based Microarray Typing Platform

    Directory of Open Access Journals (Sweden)

    Ashan Perera

    2013-05-01

    Full Text Available Many rapid methods have been developed for screening foods for the presence of pathogenic microorganisms. Rapid methods that have the additional ability to identify microorganisms via multiplexed immunological recognition have the potential for classification or typing of microbial contaminants thus facilitating epidemiological investigations that aim to identify outbreaks and trace back the contamination to its source. This manuscript introduces a novel, high throughput typing platform that employs microarrayed multiwell plate substrates and laser-induced fluorescence of the nucleic acid intercalating dye/stain SYBR Gold for detection of antibody-captured bacteria. The aim of this study was to use this platform for comparison of different sets of antibodies raised against the same pathogens as well as demonstrate its potential effectiveness for serotyping. To that end, two sets of antibodies raised against each of the “Big Six” non-O157 Shiga toxin-producing E. coli (STEC as well as E. coli O157:H7 were array-printed into microtiter plates, and serial dilutions of the bacteria were added and subsequently detected. Though antibody specificity was not sufficient for the development of an STEC serotyping method, the STEC antibody sets performed reasonably well exhibiting that specificity increased at lower capture antibody concentrations or, conversely, at lower bacterial target concentrations. The favorable results indicated that with sufficiently selective and ideally concentrated sets of biorecognition elements (e.g., antibodies or aptamers, this high-throughput platform can be used to rapidly type microbial isolates derived from food samples within ca. 80 min of total assay time. It can also potentially be used to detect the pathogens from food enrichments and at least serve as a platform for testing antibodies.

  5. Detection of Leptospira DNA in urine and presence of specific antibodies in outdoor cats in Germany.

    Science.gov (United States)

    Weis, Sonia; Rettinger, Anna; Bergmann, Michele; Llewellyn, Julia R; Pantchev, Nikola; Straubinger, Reinhard K; Hartmann, Katrin

    2017-04-01

    Objectives Clinical manifestation of infection with Leptospira species in cats is rare. Nevertheless, cats can develop specific antibodies against the spirochetes after infection. In Canada, Taiwan and the USA it was recently demonstrated that naturally infected cats can also shed DNA from pathogenic Leptospira species in their urine, but the zoonotic potential of infected cats is still unclear. The objective of this study was to demonstrate if outdoor cats in Germany shed DNA from pathogenic Leptospira species in their urine. As a second aim, antibody prevalence was determined. Methods Two hundred and fifteen outdoor cats were prospectively recruited. Urine samples were tested by real-time PCR targeting the lipL32 gene of pathogenic Leptospira species. Antibody titres against eight serovars (Australis, Autumnalis, Bratislava, Canicola, Copenhageni, Grippotyphosa, Pomona, Saxkoebing) belonging to seven serogroups (Australis, Autumnalis, Canicola, Grippotyphosa, Icterohaemorrhagiae, Pomona, Sejroe) were determined by microscopic agglutination test. Results Urine samples from 7/215 cats (3.3%; 95% confidence interval [CI] 0.9-5.7) were PCR-positive. Specific antibodies were detected in 35/195 cats (17.9%; 95% CI: 12.5-23.3) with titres ranging from 1:100 to 1:6400. Australis, Bratislava and Grippotyphosa were the most common serovars. Conclusions and relevance Outdoor cats in Germany can shed DNA from pathogenic Leptospira species. Therefore, outdoor cats should be considered as a possible source of infection for dogs or humans. Further studies are needed to determine the role of Leptospira species as a cause of disease in cats.

  6. Development of two murine antibodies against Neospora caninum using phage display technology and application on the detection of N. caninum.

    Directory of Open Access Journals (Sweden)

    Jinhua Dong

    Full Text Available Neosporosis, caused by an intracellular parasite, Neospora caninum, is an infectious disease primarily of cattle and dogs. It occurs worldwide and causes huge damages to dairy farms. In this study, we immunized mice with recombinant surface-associated protein 1 of N. caninum (rNcSAG1 and developed two novel monoclonal antibodies, A10 and H3, against NcSAG1 using phage-display technology. Both clones bound to purified rNcSAG1 and the half maximal inhibitory concentrations of A10 and H3 are 50 and 72 nM of rNcSAG1, respectively. In immunofluorescence assays, both A10 and H3 Fabs bound to N. caninum parasites. Direct detection of N. caninum parasites was developed firstly using an enzyme-linked immunosorbent assay (ELISA with A10 and H3. Binding of A10 and H3 antibodies to rNcSAG1 was also inhibited by some certain anti-N. caninum antibodies in the neosporosis-positive cattle sera, suggesting they might bind to the same epitopes of NcSAG1 with those anti-N. caninum antibodies of bovine. These antibodies were demonstrated to have a potential for monitoring the N. caninum parasites in a dairy farm, which may lead to protect livestock from parasite-infection.

  7. Antineutrophil Cytoplasmic Antibodies, Autoimmune Neutropenia, and Vasculitis

    Science.gov (United States)

    Grayson, Peter C.; Sloan, J. Mark; Niles, John L.; Monach, Paul A.; Merkel, Peter A.

    2011-01-01

    Objectives Reports of an association between antineutrophil cytoplasmic antibodies (ANCA) and autoimmune neutropenia have rarely included cases of proven vasculitis. A case of ANCA-associated vasculitis (AAV) with recurrent neutropenia is described and relevant literature on the association between ANCA, neutropenia, and vasculitis is reviewed. Methods Longitudinal clinical assessments and laboratory findings are described in a patient with AAV and recurrent episodes of profound neutropenia from December 2008 – October 2010. A PubMed database search of the medical literature was performed for papers published from 1960 through October 2010 to identify all reported cases of ANCA and neutropenia. Results A 49 year-old man developed recurrent neutropenia, periodic fevers, arthritis, biopsy-proven cutaneous vasculitis, sensorineural hearing loss, epididymitis, and positive tests for ANCA with specificity for antibodies to both proteinase 3 and myeloperoxidase. Antineutrophil membrane antibodies were detected during an acute neutropenic phase and were not detectable in a post-recovery sample, whereas ANCA titers did not seem to correlate with neutropenia. An association between ANCA and neutropenia has been reported in 74 cases from 24 studies in the context of drug/toxin exposure, underlying autoimmune disease, or chronic neutropenia without underlying autoimmune disease. In these cases, the presence of atypical ANCA patterns and other antibodies were common; however, vasculitis was uncommon and when it occurred was usually limited to the skin and in cases of underlying toxin exposure. Conclusions ANCA is associated with autoimmune neutropenia, but systemic vasculitis rarely occurs in association with ANCA and neutropenia. The interaction between neutrophils and ANCA may provide insight into understanding both autoimmune neutropenia and AAV. PMID:21507463

  8. Sensitivity and specificity of four assays to detect human T-lymphotropic virus type I or type I/II antibodies

    NARCIS (Netherlands)

    Vrielink, H.; Reesink, H. W.; Zaaijer, H. L.; van der Poel, C. L.; Cuypers, H. T.; Lelie, P. N.

    1996-01-01

    BACKGROUND: Assays that detect human T-lymphotropic virus type I and type II antibody (HTLV-I/II) are widely used in the routine screening of blood donors. STUDY DESIGN AND METHODS: Four commercially available anti-HTLV-I (Fujirebio and Organon Teknika) or -HTLV-I/II assays (Murex and Ortho) were

  9. Comparative Evaluation of Seven Commercial Tests for Detection of Heterophile Antibody in Infectious Mononucleosis

    Directory of Open Access Journals (Sweden)

    Martin Skulnick

    1992-01-01

    Full Text Available Detection of heterophile antibodies in infectious mononucleosis is the most rapid and cost-effective method for confirming the clinical diagnosis of the disease. This study compared seven commercial test kits (the Oxoid Infectious Mononucleosis Kit [Oxoid Ltd], Immunoscan Im-Latex [Baxter Travenol], Mono-Latex [Wampole Laboratories], Monospot and Im Screen Test [Ortho Diagnostics], Immunoscan Im-RBC Test [Baxter Travenol], and Infectious Mononucleosis Test [NCS Diagnostics] to the Davidsohn differential test. All of the kits were shown to be acceptable for use, with specificities and sensitivities greater than 96.5% and 95.5%, respectively.

  10. Study of FAO/IAEA/PANAFTOSA ELISA kit for the detection of antibodies against FMD

    International Nuclear Information System (INIS)

    Ravison, J.A.; Andrade Goncalves, D. de; Souza, R. de

    1998-01-01

    Two groups of sera were used to evaluate a liquid phase blocking ELISA (LPBE) for the detection of antibody against foot-and-mouth disease virus. One hundred and twenty sera, from animals with no previous history of FMD infection or vaccination, were analyzed by screening assay at a final dilution of 1:32. A second group of 120 sera, from animals vaccinated with an oil trivalent vaccine (O, A, C) were tested by titration in the LPBE. All the sera were tested against virus of three FMD serotypes, using O 1 Campos, A 24 Cruzeiro, C 3 Indaial virus strains. (author)

  11. An antibody toolkit for the study of membrane traffic in Drosophila melanogaster

    Directory of Open Access Journals (Sweden)

    Falko Riedel

    2016-07-01

    Full Text Available The use of Drosophila melanogaster as a model organism has been pivotal to understanding the developmental processes of metazoans. However, the use of flies for studying subcellular organization is hampered by a paucity of reliable reagents to label specific organelles. Here, we describe the generation of mouse monoclonal antibodies against a set of markers of the secretory and endocytic pathways, along with goat polyclonal antibodies against two Golgi proteins. We show that the monoclonal antibodies are highly specific and sufficiently sensitive to detect endogenous proteins in crude extracts by immunoblotting with little background staining. By immunofluorescence the major compartments of the membrane traffic system (including the endoplasmic reticulum, the Golgi, and early and late endosomes are labeled by at least one antibody. Moreover, the antibodies can be used to label organelles in fly tissues including salivary glands and wing imaginal discs. We anticipate that these antibodies will provide a useful tool kit to facilitate the investigation of how the endomembrane system functions and varies in the diverse tissue types of metazoans.

  12. Use and limitations of radiolabelled anti-CEA antibodies and their fragments for photoscanning detection of human colorectal carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Mach, J P; Forni, M; Ritschard, J; Buchegger, F; Carrel, S; Widgren, S; Donath, A; Alberto, P [Lausanne Univ. (Switzerland)

    1980-08-01

    Fifty-three patients with histologically proven carcinoma were injected with highly purified (/sup 131/I)-labelled goat antibodies or fragments of antibodies against carcinoembryonic antigen (CEA). Each patient was tested by external photoscanning 4, 24, 36, 48h after injection. In 22 patients (16 of 38 injected with intact antibodies, 5 of 13 with F(ab')/sub 2/ fragments and 1 of 2 with Fab' fragments), an increased concentration of /sup 131/I radioactivity corresponding to the previously known tumor location was detected by photoscanning 36-48 h after injection. Blood pool and secreted radioactivity was determined in all patients by injecting 15 min after scanning, (sup(99m)Tc)-labeled normal serum albumin and free sup(99m)TcO/sub 4//sup -/. The computerized subtraction of sup(99m)Tc from /sup 131/I radioactivity enhanced the definition of tumor localization in the 22 positive patients. However, in spite of the computerized subtraction, interpretation of the scans remained doubtful for 12 patients and was entirely negative for 19 additional patients.

  13. Detection of circulating immune complexes in hepatitis by means of a new method employing /sup 125/I-antibody. Circulating immune complexes in hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Fresco, G F [Genoa Univ. (Italy). Dept. of Internal Medicine

    1978-06-01

    A new RIA method for the detection of circulating immune complexes and antibodies arising in the course of viral hepatitis is described. It involves the use of /sup 125/I-labeled antibodies and foresees the possibility of employing immune complex-coated polypropylene tubes. This simple and sensitive procedure takes into account the possibility that the immune complexes may be absorbed by the surface of polypropylene tubes during the period in which the serum remains there.

  14. An enzyme-linked immunosorbent assay for detection of avian influenza virus subtypes H5 and H7 antibodies

    DEFF Research Database (Denmark)

    Jensen, Trine Hammer; Ajjouri, Gitte; Handberg, Kurt

    2013-01-01

    subtypes H5 and H7. The ELISAs were evaluated with polyclonal chicken anti-AIV antibodies against AIV subtypes: H1N2, H5N2, H5N7, H7N1, H7N7, H9N9, H10N4 and H16N3. RESULTS: Both the H5 and H7 ELISA proved to have a high sensitivity and specificity and the ELISAs detected H5 and H7 antibodies earlier......BACKGROUND: Avian influenza virus (AIV) subtypes H5 and H7 attracts particular attention because of the risk of their potential pathogenicity in poultry. The haemagglutination inhibition (HI) test is widely used as subtype specific test for serological diagnostics despite the laborious nature...

  15. Conjugation of biotin-coated luminescent quantum dots with single domain antibody-rhizavidin fusions

    Directory of Open Access Journals (Sweden)

    Jinny L. Liu

    2016-06-01

    Full Text Available Straightforward and effective methods are required for the bioconjugation of proteins to surfaces and particles. Previously we demonstrated that the fusion of a single domain antibody with the biotin binding molecule rhizavidin provided a facile method to coat biotin-modified surfaces with a highly active and oriented antibody. Here, we constructed similar single domain antibody—rhizavidin fusions as well as unfused rhizavidin with a His-tag. The unfused rhizavidin produced efficiently and its utility for assay development was demonstrated in surface plasmon resonance experiments. The single domain antibody-rhizavidin fusions were utilized to coat quantum dots that had been prepared with surface biotins. Preparation of antibody coated quantum dots by this means was found to be both easy and effective. The prepared single domain antibody-quantum dot reagent was characterized by surface plasmon resonance and applied to toxin detection in a fluoroimmunoassay sensing format.

  16. Dual antibody therapy to harness the innate anti-tumor immune response to enhance antibody targeting of tumors.

    Science.gov (United States)

    Chester, Cariad; Marabelle, Aurelien; Houot, Roch; Kohrt, Holbrook E

    2015-04-01

    Cancer immunotherapy is a rapidly evolving field that offers a novel paradigm for cancer treatment: therapies focus on enhancing the immune system's innate and adaptive anti-tumor response. Early immunotherapeutics have achieved impressive clinical outcomes and monoclonal antibodies are now integral to therapeutic strategies in a variety of cancers. However, only recently have antibodies targeting innate immune cells entered clinical development. Innate immune effector cells play important roles in generating and maintaining antitumor immunity. Antibody-dependent cell-mediated cytotoxicity (ADCC) and antibody-dependent cellular phagocytosis (ADCP) are important innate immune mechanisms for tumor eradication. These cytolytic processes are initiated by the detection of a tumor-targeting antibody and can be augmented by activating co-stimulatory pathways or blocking inhibitory signals on innate immune cells. The combination of FDA-approved monoclonal antibodies with innate effector-targeting antibodies has demonstrated potent preclinical therapeutic synergy and early-phase combinatorial clinical trials are ongoing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. [Detection and the production mechanism of antinuclear antibodies (ANA) and anti-liver/kidney microsomal tpe 1 antibodies (anti-LKM1) in patients with chronic hepatitis C].

    Science.gov (United States)

    Bai, Li; Lu, Hai-Ying; Feng, Zhen-Ru; Yu, Min; Li, Wen-Gang; Gong, Wei-Bo; Zhao, Nu-en-ji-ya; Xu, Xiao-Yuan

    2009-08-01

    To investigate the prevalence of antinuclear antibodies (ANA) and anti-liver/ kidney microsomal type 1 antibodies (anti-LKM1) in patients with chronic hepatitis C (CHC)and to explore the mechanism of production of these autoantibodies. Serum samples were collected from 360 patients with CHC (case group), 69 patients with chronic hepatitis B (CHB) and 69 patients with autoimmune hepatitis (AIH) (control group). Serum ANA and anti-LKM1 were detected by indirect immunofluorescence (HF) technique and enzyme-linked immunosorbent assay (ELISA), respectively. Multi-factor analysis was performed to explore the correlations of the production of autoantibodies with some factors such as age, sex, viral loads, HCV genotype, biochemical parameters and clinical characteristics. Fifty-four (15%) of 360 patients infected with HCV were positive in autoantibodies. The prevalence of ANA and anti-LKM1 were 12.5% (45/360) and 2.5% (9/ 360), respectively. The positive rate of autoantibodies in patients with CHC was significantly higher than that in patients with CHB (15% vs 2.9%, P = 0.006), but significantly lower than that in patients with AIH (15% vs 47.9%, P 0.05). Autoantibodies related to AIH can be detected in CHC patients; interferon may not induce the production of autoantibodies; it is very likely that HCV infection induces the autoimmune reaction and the production of autoantibodies.

  18. Coombs Antiglobulin Test Using Brucella abortus 99 as Antigen To Detect Incomplete Antibodies Induced by B. abortus RB51 Vaccine in Cattle

    OpenAIRE

    Ciuchini, Franco; Adone, Rosanna; Pasquali, Paolo

    2002-01-01

    This study showed that vaccination of cattle with Brucella abortus rough strain RB51 induces incomplete antibodies that can be detectable by a Coombs antiglobulin test using the B. abortus 99 smooth strain.

  19. Sensitive Detection of Capsaicinoids Using a Surface Plasmon Resonance Sensor with Anti-Homovanillic Acid Polyclonal Antibodies

    Directory of Open Access Journals (Sweden)

    Kiyoshi Toko

    2013-11-01

    Full Text Available Recently, highly functional biosensors have been developed in preparation for possible large-scale terrorist attacks using chemical warfare agents. Practically applicable sensors are required to have various abilities, such as high portability and operability, the capability of performing rapid and continuous measurement, as well as high sensitivity and selectivity. We developed the detection method of capsaicinoids, the main component of some lachrymators, using a surface plasmon resonance (SPR immunosensor as an on-site detection sensor. Homovanillic acid, which has a vanillyl group similar to capsaicinoids such as capsaicin and dihydrocapsaicin, was bound to Concholepas concholepas hemocyanin (CCH for use as an immunogen to generate polyclonal antibodies. An indirect competitive assay was carried out to detect capsaicinoids using SPR sensor chips on which different capsaicin analogues were immobilized. For the sensor chip on which 4-hydroxy-3-methoxybenzylamine hydrochloride was immobilized, a detection limit of 150 ppb was achieved. We found that the incubation time was not required and the detection can be completed in five minutes.

  20. Sequential use of indium-111 labeled monoclonal antibodies 96.5 and ZME-018 does not increase detection sensitivity for metastatic melanoma

    International Nuclear Information System (INIS)

    Frontiera, M.; Murray, J.L.; Lamki, L.

    1989-01-01

    Two indium-111 labeled anti-melanoma murine monoclonal antibodies (MAb), 96.5 and ZME-018, each recognizing separate antigens on melanoma cells, were administered intravenously to 17 patients with melanoma in a sequential fashion to determine whether: (1) additional tumor sites could be imaged with the combination compared to a single Mab; (2) the first MAb influenced the biodistribution and tumor localization of the second; and (3) significantly toxicity occurred with the combination. Patients were randomized to receive either 96.5, followed by ZME-018, ZME-018 followed by 96.5, or each MAb followed by itself (controls). Infusions of the second MAb occurred 10 days after the first infusion. Gamma camera images were obtained 72 hours after each antibody infusion. There were 139 known metastatic sites of which 72 lesions were localized by either MAb for an overall sensitivity of 52%. The detection rate was higher when lesions only greater than 1.5 cm were considered. Imaging results were independent of MAb administration sequence. When ZME-018 was given as the first infusion, when ZME-018 was given as a second infusion (p = NS). However, mean sensitivities using 96.5 as the first or second infusion were 48% and 66% respectively (p = NS). There was not a significant number of sites detected by MAb 2 that were missed by MAb 1. Human anti-murine antibody (HAMA) response occurred in seven of eight patients studied; two patients who experienced toxicity had levels of HAMA greater than 2000 ng/ml. We conclude that the use of these two murine anti-melanoma monoclonal antibodies given in sequential fashion did not significantly change the imaging sensitivity from that seen with each individual antibody

  1. The detection of hemorrhagic proteins in snake venoms using monoclonal antibodies against Virginia opossum (Didelphis virginiana) serum.

    Science.gov (United States)

    Sánchez, E E; García, C; Pérez, J C; De La Zerda, S J

    1998-10-01

    Most snakes and a few warm-blooded animals have a resistance to snake venoms because of naturally occurring antihemorrhagins found in their sera. The antihemorrhagins in serum of Virginia opossum (Didelphis virginiana) neutralize hemorrhagic activity by binding to hemorrhagins in snake venoms. The binding characteristic of antihemorrhagins in D. virginiana serum was used to develop a five-step western blot. The detection of hemorrhagic proteins were measured indirectly with antihemorrhagins in Virginia opossum serum and with DV-2LD#2, a monoclonal antibody specific for Virginia opossum antihemorrhagins. Snake venoms were separated by native-PAGE, transferred to a Millipore Immobilon-P membrane and then incubated with crude Virginia opossum serum. The hemorrhagins in snake venom bind to antihemorrhagins in Virginia opossum serum which react with DV-2LD#2 a monoclonal antibody that is specific for Virginia opossum antihemorrhagins. DV-2LD#2 monoclonal antibody inhibits antihemorrhagic activity in Virginia opossum serum when mixed in equal amounts. The inhibition of antihemorrhagins by DV-2LD#2 monoclonal antibody suggests specificity. DV-2LD#2 monoclonal antibody does not recognize antihemorrhagins in gray woodrat (Neotoma micropus) serum. The five-step western blot reveals two well-defined bands which represent hemorrhagins found in Western diamondback rattlesnake (Crotalus atrox) venom. Venoms from 15 different snake species were examined to determine the usefulness of the five-step western blot. Other hemorrhagic venoms (Great Basin rattlesnake (C. viridis lutosus), Prairie rattlesnake (C. viridis viridis), Tancitaran dusky rattlesnake (C. pusillus), Northern Mojave rattlesnake (C. scutulatus scutulatus type B) and Northern Pacific rattlesnake (C. v. oreganus)) had one single band in the five-step western blot. DV-2LD#2 did not bind to the non-hemorrhagic venoms and reacted with 50% of the hemorrhagic venoms used in this study. The monoclonal antibody, CAH

  2. Comparison of a commercial ELISA and an immunoperoxidase monolayer assay to detect antibodies directed against porcine respiratory and reproductive syndrome virus

    NARCIS (Netherlands)

    Nodelijk, G.; Wensvoort, G.; Kroese, B.; Leengoed, van L.A.M.G.; Colijn, E.; Verheijden, J.H.M.

    1996-01-01

    A commercially available enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against porcine respiratory and reproductive syndrome virus (PRRSV) was compared to an immunoperoxidase monolayer assay (IPMA). Serum samples used were collected from pigs experimentally infected with

  3. Isolation and characterization of a monoclonal anti-protein kinase CK2 beta-subunit antibody of the IgG class for the direct detection of CK2 beta-subunit in tissue cultures of various mammalian species and human tumors

    DEFF Research Database (Denmark)

    Nastainczyk, W; Schmidt-Spaniol, I; Boldyreff, B

    1995-01-01

    A murine monoclonal anti-protein kinase CK2 beta antibody was isolated and characterized. The antibody detects 1 pmol of purified recombinant CK2 beta-subunit after analysis on SDS-PAGE. Alternatively undenatured CK2 beta-subunit was detected by an ELISA assay either as recombinant CK2 beta......-subunit or in the CK2 holoenzyme (alpha 2 beta 2). Here, concentrations of the first antibody of 1 ng/ml still allowed the detection of the subunit. Immunoblotting of crude cellular extracts from various tissue cultures (man, mouse, and hamster), from human tumors, and the nonneoplastic tissue allowed the detection...... of the CK2 beta-subunit. The detected epitope of this antibody was, as determined by the epitope analysis technique, 123GLSDI127....

  4. An ultra-sensitive monoclonal antibody-based fluorescent microsphere immunochromatographic test strip assay for detecting aflatoxin M1 in milk

    Science.gov (United States)

    A rapid lateral flow fluorescent microspheres immunochromatography test strip (FMs-ICTS) has been developed for the detection of aflatoxin M1 (AFM1) residues in milk. For this purpose, an ultra-sensitive anti-AFM1 monoclonal antibody (MAb) 1D3 was prepared and identified. The IC50 value of the MA...

  5. Mammalian tissue distribution of a large heparan sulfate proteoglycan detected by monoclonal antibodies

    DEFF Research Database (Denmark)

    Couchman, J R; Ljubimov, A V

    1989-01-01

    muscle, endothelia, peripheral nerve fibers and epithelia so far examined. In addition, two of the monoclonal antibodies show cross-species reactivity, staining bovine and human basement membranes, and immunoprecipitating proteoglycans from human endothelial cell cultures. These antibodies do not......A panel of nine monoclonal antibodies has been characterized, all of which have reactivity with the core protein of a large heparan sulfate proteoglycan derived from the murine EHS tumor matrix. These rat monoclonal antibodies stained mouse basement membranes intensely, including those of all...

  6. Investigations on the protective role of passively transferred antibodies against avian metapneumovirus infection in turkeys.

    Science.gov (United States)

    Rubbenstroth, Dennis; Rautenschlein, Silke

    2009-12-01

    The avian metapneumovirus (aMPV) is the causative agent of an acute respiratory disease in turkeys, which causes considerable economic losses to the poultry industry. Currently attenuated live and inactivated vaccines are widely used to control the disease, but vaccine breaks are frequently observed. For improvement of current vaccination strategies it is necessary to gain enhanced knowledge of the immune mechanisms against aMPV infection. Field observations suggest that vaccine-induced aMPV-specific antibodies are not indicative for protection. In the present study we investigated the role of antibodies in protection of turkeys against aMPV. In two experiments, commercial turkey poults received aMPV-specific antibodies by intravenous injection. The antibody transfer resulted in increased antibody levels in the sera. Virus-specific antibodies were also detected on mucosal surfaces such as the trachea, conjunctivae and gall bladder. Turkeys were subsequently challenged with a virulent aMPV subtype A strain. Development of clinical signs, virus detection by polymerase chain reaction and histopathological changes of tracheal mucosa in challenged turkeys with and without passively transferred antibodies were comparable with each other. Our results suggest that humoral immunity does not provide sufficient protection against aMPV infection. Thus, the measurement of vaccine-induced aMPV antibody response may not be considered as an adequate indicator of vaccine efficacy. Further research on the protective role of cell-mediated immune mechanisms is necessary to improve current vaccine strategies.

  7. Sensitive radioimmunoassay for the determination of antibodies to mouse hepatitis virus

    Energy Technology Data Exchange (ETDEWEB)

    Leibowitz, J L [California Univ., San Diego, La Jolla (USA); Fung, L S; Levy, G A [Toronto Univ., Ontario (Canada)

    1983-05-01

    A solid-phase radioimmunoassay is described for the detection of antibodies to mouse hepatitis virus. Viruses were purified by velocity and isopycnic gradient centrifugation and 96-well plastic plates were coated with viral antigens. To allow the detection of most serotypes of low titered antisera, a pool of antigens from several viral serotypes were employed. The second antibody, an affinity-purified goat antimouse immunoglobulin, detects IgG, IgM and IgA antibodies. This assay is more sensitive than either the plaque reduction assay or the commercially available enzyme-linked immunosorbant assay and proved to be useful for screening mouse colonies for the presence of mouse hepatitis virus, following seroconversion in experimental animals and in the production of monoclonal antibodies to both structural and nonstructural proteins.

  8. Detection of phase I IgG antibodies to Coxiella burnetii with EIA as a screening test for blood donations.

    Science.gov (United States)

    van der Hoek, W; Wielders, C C H; Schimmer, B; Wegdam-Blans, M C A; Meekelenkamp, J; Zaaijer, H L; Schneeberger, P M

    2012-11-01

    The presence of a high phase I IgG antibody titre may indicate chronic infection and a risk for the transmission of Coxiella burnetii through blood transfusion. The outbreak of Q fever in the Netherlands allowed for the comparison of an enzyme immunoassay (EIA) with the reference immunofluorescence assay (IFA) in a large group of individuals one year after acute Q fever. EIA is 100 % sensitive in detecting high (≥1:1,024) phase I IgG antibody titres. The cost of screening with EIA and confirming all EIA-positive results with IFA is much lower than screening all donations with IFA. This should be taken into account in cost-effectiveness analyses of screening programmes.

  9. Radioimmunoassay of IgM, IgG, and IgA brucella antibodies

    International Nuclear Information System (INIS)

    Parrett, D.; Nielson, K.H.; White, R.G.; Payne, D.J.H.

    1977-01-01

    A radioimmunoassay (R.I.A.) has been devised to measure the serum antibody against Brucella abortus in each of the immunoglobulin classes IgM, IgG, and IgA. This test was applied to 46 sera from individuals with various clinical types of brucellosis, and the results were compared with the results of conventional direct and indirect agglutination and complement-fixation tests. The R.I.A. provided a highly sensitive primary-type assay which avoided the difficulties with blocking or non-agglutinating antibody, and thus has many advantages in the diagnosis of acute and chronic stages of brucella infection in man. The R.I.A. was successful in detection of antibody in many instances in which conventional serological tests were negative, and such antibody could (if IgM) be associated with acute or (if IgG or IgA) with chronic cases of brucellosis. One case in which B.abortus was isolated by blood culture but which failed to yield antibody by conventional tests, nevertheless showed substantial levels of IgM and IgG antibody by R.I.A. In other cases the R.I.A. test helped to eliminate the diagnosis of brucellosis by revealing absent or low antibody levels. (author)

  10. Hypersensitive detection and quantitation of BoNT/A by IgY antibody against substrate linear-peptide.

    Directory of Open Access Journals (Sweden)

    Tao Li

    Full Text Available Botulinum neurotoxin A (BoNT/A, the most acutely poisonous substance to humans known, cleave its SNAP-25 substrate with high specificity. Based on the endopeptidase activity, different methods have been developed to detect BoNT/A, but most lack ideal reproducibility or sensitivity, or suffer from long-term or unwanted interferences. In this study, we developed a simple method to detect and quantitate trace amounts of botulinum neurotoxin A using the IgY antibody against a linear-peptide substrate. The effects of reaction buffer, time, and temperature were analyzed and optimized. When the optimized assay was used to detect BoNT/A, the limit of detection of the assay was 0.01 mouse LD50 (0.04 pg, and the limit of quantitation was 0.12 mouse LD50/ml (0.48 pg. The findings also showed favorable specificity of detecting BoNT/A. When used to detect BoNT/A in milk or human serum, the proposed assay exhibited good quantitative accuracy (88% < recovery < 111%; inter- and intra-assay CVs < 18%. This method of detection took less than 3 h to complete, indicating that it can be a valuable method of detecting BoNT/A in food or clinical diagnosis.

  11. Studies on the detection of erythrocytic antibodies with a radioimmuno-antiglobulin assay

    International Nuclear Information System (INIS)

    Djibey, I.M.

    1979-01-01

    The RIA with I-125-anti-IgG and I-125-anti-C3b was used. Various factors in RIA were tested for the purpose of optimisation. As a rule, incomplete anti-D (test serum of one charge) was used. Anti-Kell was used for specific problems. After optimisation of the method, patient sera were studied which contained auto- or allo-antibodies in the fresh state. More significant findings were obtained with the direct RIAGT. Indirect methods did not show a clearly enhanced detection sensitivity of erythrocyte autoantibodies, but they may serve for a closer investigation of diffuse reactions of patient sera in the enzyme test. The direct RIA is clearly of advantage in cases in which the complement Coombs test alone is positive. (orig./MG) [de

  12. Plasmon enhanced fluoro-immunoassay using egg yolk antibodies for ultra-sensitive detection of herbicide diuron.

    Science.gov (United States)

    Sharma, Priyanka; Kukkar, Manil; Ganguli, Ashok K; Bhasin, Aman; Suri, C Raman

    2013-08-07

    Plasmon enhanced fluorescence immunoassay (PEFI) format has been reported in developing a sensitive heterogeneous fluoroimmunoassay for monitoring the phenylurea herbicide diuron. Computer-assisted molecular modeling was carried out to study the conformational and electrostatic effects of synthesized hapten for producing highly specific egg yolk antibody against a phenyl urea herbicide diuron. The generated antibodies were labeled with fluorescein isothiocyanate at different molar ratios and used as tracer in the developed fluorescence based immunoassay. The sensitivity of the assay format was enhanced by using silver nanoparticles tagged with bovine serum albumin as a new blocking reagent in the developed PEFI format. Enhancer treatment on the developed immunoassay showed a significant improvement of fluorescence signal intensity with approximately 10 fold increase in assay sensitivity. The immunoassay has a detection limit of 0.01 ng mL(-1) with good signal precision (~2%) in the optimum working concentration range between 1 pg mL(-1) to 10 μg mL(-1) of diuron. These findings facilitate high throughput fluorescence-based processes that could be useful in biology, drug discovery and compound screening applications.

  13. Detection and quantification of Duffy antigen on bovine red blood cell membranes using a polyclonal antibody

    Directory of Open Access Journals (Sweden)

    Ana Teresa B.F. Antonangelo

    2012-09-01

    Full Text Available Babesiosis is one of the most important diseases affecting livestock agriculture worldwide. Animals from the subspecies Bos taurus indicus are more resistant to babesiosis than those from Bos taurus taurus. The genera Babesia and Plasmodium are Apicomplexa hemoparasites and share features such as invasion of red blood cells (RBC. The glycoprotein Duffy is the only human erythrocyte receptor for Pasmodium vivax and a mutation which abolishes expression of this glycoprotein on erythrocyte surfaces is responsible for making the majority of people originating from the indigenous populations of West Africa resistant to P. vivax. The current work detected and quantified the Duffy antigen on Bos taurus indicus and Bos taurus taurus erythrocyte surfaces using a polyclonal antibody in order to investigate if differences in susceptibility to Babesia are due to different levels of Duffy antigen expression on the RBCs of these animals, as is known to be the case in human beings for interactions of Plasmodium vivax-Duffy antigen. ELISA tests showed that the antibody that was raised against Duffy antigens detected the presence of Duffy antigen in both subspecies and that the amount of this antigen on those erythrocyte membranes was similar. These results indicate that the greater resistance of B. taurus indicus to babesiosis cannot be explained by the absence or lower expression of Duffy antigen on RBC surfaces.

  14. Antibody Engineering & Therapeutics 2016: The Antibody Society's annual meeting, December 11-15, 2016, San Diego, CA.

    Science.gov (United States)

    Larrick, James W; Alfenito, Mark R; Scott, Jamie K; Parren, Paul W H I; Burton, Dennis R; Bradbury, Andrew R M; Lemere, Cynthia A; Messer, Anne; Huston, James S; Carter, Paul J; Veldman, Trudi; Chester, Kerry A; Schuurman, Janine; Adams, Gregory P; Reichert, Janice M

    Antibody Engineering & Therapeutics, the largest meeting devoted to antibody science and technology and the annual meeting of The Antibody Society, will be held in San Diego, CA on December 11-15, 2016. Each of 14 sessions will include six presentations by leading industry and academic experts. In this meeting preview, the session chairs discuss the relevance of their topics to current and future antibody therapeutics development. Session topics include bispecifics and designer polyclonal antibodies; antibodies for neurodegenerative diseases; the interface between passive and active immunotherapy; antibodies for non-cancer indications; novel antibody display, selection and screening technologies; novel checkpoint modulators / immuno-oncology; engineering antibodies for T-cell therapy; novel engineering strategies to enhance antibody functions; and the biological Impact of Fc receptor engagement. The meeting will open with keynote speakers Dennis R. Burton (The Scripps Research Institute), who will review progress toward a neutralizing antibody-based HIV vaccine; Olivera J. Finn, (University of Pittsburgh School of Medicine), who will discuss prophylactic cancer vaccines as a source of therapeutic antibodies; and Paul Richardson (Dana-Farber Cancer Institute), who will provide a clinical update on daratumumab for multiple myeloma. In a featured presentation, a representative of the World Health Organization's INN expert group will provide a perspective on antibody naming. "Antibodies to watch in 2017" and progress on The Antibody Society's 2016 initiatives will be presented during the Society's special session. In addition, two pre-conference workshops covering ways to accelerate antibody drugs to the clinic and the applications of next-generation sequencing in antibody discovery and engineering will be held on Sunday December 11, 2016.

  15. Development of Two Antibody Detection Enzyme-Linked Immunosorbent Assays for Serodiagnosis of Human Chronic Fascioliasis

    Science.gov (United States)

    Cabán-Hernández, Kimberly; Gaudier, José F.; Ruiz-Jiménez, Caleb

    2014-01-01

    Coprological examination based on egg detection in stool samples is currently used as the gold standard for the diagnosis of human fascioliasis. However, this method is not effective during the acute phase of the disease and has poor sensitivity during the chronic phase. Serodiagnosis has become an excellent alternative to coprological examination in efforts to combat the effects of fascioliasis on human and animal health. Two novel recombinant Fasciola hepatica proteins, i.e., a ferritin (FhFtn-1) and a tegument-associated protein (FhTP16.5), were used as antigens to develop in-house enzyme-linked immunosorbent assay (ELISA) methods. The assays were optimized and validated using 152 serum samples from humans with a known infection status, including healthy subjects, patients with chronic fascioliasis, and patients with other parasitic diseases. The FhFtn-1 ELISA was shown to be 96.6% sensitive and 95.7% specific; the respective parameters for the FhTP16.5 ELISA were 91.4% and 92.4%. The performances of the FhFtn-1 and FhTP16.5 ELISAs were compared with that of an available commercial test (the DRG test) using a subset of serum samples. Our in-house tests were slightly more sensitive than the DRG test in detecting antibodies against F. hepatica, but the differences were not statistically significant. In conclusion, the present study provides evidence for the potential of the FhFtn-1 and FhTP16.5 ELISAs as diagnostic tools for human fascioliasis, as might be implemented in conjunction with standard assays for large-scale screenings in areas where the disease is endemic and for the detection of occasional cases in clinical laboratories. PMID:24353000

  16. Development of two antibody detection enzyme-linked immunosorbent assays for serodiagnosis of human chronic fascioliasis.

    Science.gov (United States)

    Cabán-Hernández, Kimberly; Gaudier, José F; Ruiz-Jiménez, Caleb; Espino, Ana M

    2014-03-01

    Coprological examination based on egg detection in stool samples is currently used as the gold standard for the diagnosis of human fascioliasis. However, this method is not effective during the acute phase of the disease and has poor sensitivity during the chronic phase. Serodiagnosis has become an excellent alternative to coprological examination in efforts to combat the effects of fascioliasis on human and animal health. Two novel recombinant Fasciola hepatica proteins, i.e., a ferritin (FhFtn-1) and a tegument-associated protein (FhTP16.5), were used as antigens to develop in-house enzyme-linked immunosorbent assay (ELISA) methods. The assays were optimized and validated using 152 serum samples from humans with a known infection status, including healthy subjects, patients with chronic fascioliasis, and patients with other parasitic diseases. The FhFtn-1 ELISA was shown to be 96.6% sensitive and 95.7% specific; the respective parameters for the FhTP16.5 ELISA were 91.4% and 92.4%. The performances of the FhFtn-1 and FhTP16.5 ELISAs were compared with that of an available commercial test (the DRG test) using a subset of serum samples. Our in-house tests were slightly more sensitive than the DRG test in detecting antibodies against F. hepatica, but the differences were not statistically significant. In conclusion, the present study provides evidence for the potential of the FhFtn-1 and FhTP16.5 ELISAs as diagnostic tools for human fascioliasis, as might be implemented in conjunction with standard assays for large-scale screenings in areas where the disease is endemic and for the detection of occasional cases in clinical laboratories.

  17. Detection of FMD virus type specific IgG1, IgG2 and IgA antibodies in milk and serum of buffaloes vaccinated with oil adjuvanted polyvalent FMD vaccine

    Directory of Open Access Journals (Sweden)

    R. Sharma

    2010-02-01

    Full Text Available The present investigation was carried out on 15 randomly selected milch buffaloes divided into three groups on the basis of lactation at an organized farm, to study the foot and mouth disease virus type specific antibodies in milk and serum following FMD vaccination. Milk and serum samples collected before vaccination i.e. 0 day and on 7, 14, 28, 42 and 56 days post vaccination, were analyzed for the detection of FMD virus specific IgG1, IgG2 and IgA antibody response by indirect double antibody sandwich ELISA. Significant FMD virus type specific antibody titres (IgG1, IgG2 and IgA were detected in milk and serum of buffaloes on different days post vaccination, though the levels of antibodies were lower in milk as compared to serum. FMD virus type specific IgG1 was found to be the predominant subclass as compared to IgG2 and IgA both in milk and serum of vaccinated buffaloes. Milk and serum IgG1, IgG2 and IgA antibody titres were positively correlated with values of regression coefficient (R as 0.506, 0.434 and 0.396, respectively.

  18. Carbamylated albumin is one of the target antigens of anti-carbamylated protein antibodies.

    Science.gov (United States)

    Nakabo, Shuichiro; Hashimoto, Motomu; Ito, Shinji; Furu, Moritoshi; Ito, Hiromu; Fujii, Takao; Yoshifuji, Hajime; Imura, Yoshitaka; Nakashima, Ran; Murakami, Kosaku; Kuramoto, Nobuo; Tanaka, Masao; Satoh, Junko; Ishigami, Akihito; Morita, Satoshi; Mimori, Tsuneyo; Ohmura, Koichiro

    2017-07-01

    Anti-carbamylated protein (anti-CarP) antibodies are detected in RA patients. Fetal calf serum is used as an antigen source in anti-CarP ELISA, and the precise target antigens have not been found. We aimed to identify the target antigens of anti-CarP antibodies. Western blotting of anti-CarP antibodies was conducted. Anti-carbamylated human albumin (CarALB) antibody was detected by in-house ELISA for 493 RA patients and 144 healthy controls (HCs). An inhibition ELISA of anti-CarP antibodies by CarALB and citrullinated albumin (citALB) was performed using eight RA patients' sera. Serum CarALB was detected by liquid chromatography-tandem mass spectroscopy (LC/MS/MS), and the serum MPO concentration was measured by ELISA. We focused on carbamylated albumin because it corresponded to the size of the thickest band detected by western blotting of anti-CarP antibodies. Anti-CarALB antibody was detected in 31.4% of RA patients, and the correlation of the titres between anti-CarALB and anti-CarP was much closer than that between anti-citALB and anti-CCP antibodies (ρ = 0.59 and ρ = 0.16, respectively). The inhibition ELISA showed that anti-CarP antibodies were inhibited by CarALB, but not by citALB. CarALB was detected in sera from RA patients by LC/MS/MS. The serum MPO concentration was correlated with disease activity and was higher in RA patients with anti-CarALB antibody than in those without. We found that carbamylated albumin is a novel target antigen of anti-CarP antibodies, and it is the first reported target antigen that has not been reported as the target of ACPA. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  19. Development of a monoclonal antibody against the left wing of ciguatoxin CTX1B: thiol strategy and detection using a sandwich ELISA.

    Science.gov (United States)

    Tsumuraya, Takeshi; Takeuchi, Katsutoshi; Yamashita, Shuji; Fujii, Ikuo; Hirama, Masahiro

    2012-09-01

    Ciguatera fish poisoning (CFP) is a form of food poisoning caused by the ingestion of a variety of reef fish that have accumulated trace amounts of ciguatoxins produced by dinoflagellates of the genus Gambierdiscus through the food chain. CFP affects more than 50,000 people each year. The extremely low level of the causative neurotoxins, ciguatoxins, in fish has hampered the preparation of antibodies for detecting the toxins. In this paper, we describe a thiol strategy for synthesizing a keyhole limpet hemocyanin (KLH)-conjugate (20) of the ABCDE-ring fragment of the Pacific ciguatoxins, CTX1B (1) and 54-deoxyCTX1B (4). We succeeded in producing a monoclonal antibody (3G8) against the left wings of these ciguatoxins by immunizing mice with the hapten-KLH conjugate (20) as the synthetic antigen. The most promising mAb, 3G8, does not cross-react with other related marine toxins. Sandwich enzyme-linked immunosorbent assay (ELISA) utilizing 3G8 and the previously prepared monoclonal antibody (8H4) enabled us to detect 1 specifically at less than 0.28 ng/mL. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Antibodies to H5 subtype avian influenza virus and Japanese encephalitis virus in northern pintails (Anas acuta) sampled in Japan

    Science.gov (United States)

    Ramey, Andy M.; Spackman, Erica; Yeh, Jung-Yong; Fujita, Go; Konishi, Kan; Reed, John A.; Wilcox, Benjamin R.; Brown, Justin D.; Stallknecht, David E.

    2013-01-01

    Blood samples from 105 northern pintails (Anas acuta) captured on Hokkaido, Japan were tested for antibodies to avian influenza virus (AIV), Japanese encephalitis virus (JEV), and West Nile virus (WNV) to assess possible involvement of this species in the spread of economically important and potentially zoonotic pathogens. Antibodies to AIV were detected in 64 of 105 samples (61%). Of the 64 positives, 95% and 81% inhibited agglutination of two different H5 AIV antigens (H5N1 and H5N9), respectively. Antibodies to JEV and WNV were detected in five (5%) and none of the samples, respectively. Results provide evidence for prior exposure of migrating northern pintails to H5 AIV which couldhave implications for viral shedding and disease occurrence. Results also provide evidence for limited involvement of this species in the transmission and spread of flaviviruses during spring migration.